  1. Impact of applying the more stringent validation criteria of the revised European Society of Hypertension International Protocol 2010 on earlier validation studies.

    Science.gov (United States)

    Stergiou, George S; Karpettas, Nikos; Atkins, Neil; O'Brien, Eoin

    2011-04-01

    Since 2002 when the European Society of Hypertension International Protocol (ESH-IP) was published it has become the preferred protocol for validating blood pressure monitors worldwide. In 2010, a revised version of the ESH-IP with more stringent criteria was published. This study assesses the impact of applying the revised ESH-IP criteria. A systematic literature review of ESH-IP studies reported between 2002 and 2010 was conducted. The impact of applying the ESH-IP 2010 criteria retrospectively on the data reported in these studies was investigated. The performance of the oscillometric devices in the last decade was also investigated on the basis of the ESH-IP criteria. Among 119 published studies, 112 with sufficient data were analyzed. According to ESH-IP 2002, the test device failed in 19 studies, whereas by applying the ESH-IP 2010 criteria in 28 additional studies increased the failure rate from 17 to 42%. Of these 28 studies, in 20 (71%) the test device failed at part 1 (accuracy per measurement) and in 22 (79%) at part 2 (accuracy per subject). Most of the failures involved the '5 mmHg or less' criterion. In the last decade there has been a consistent trend toward improved performance of oscillometric devices assessed on the basis of the ESH-IP criteria. This retrospective analysis shows that the stricter revised ESH-IP 2010 criteria will noticeably increase the failure rate of devices being validated. Oscillometric devices are becoming more accurate, and the revised ESH-IP by acknowledging this trend will allow more accurate devices to enter the market.

  2. Carotid Consensus Panel duplex criteria can replace modified University of Washington criteria without affecting accuracy.

    Science.gov (United States)

    Kim, Ann H; Augustin, Gener; Shevitz, Andrew; Kim, Hannah; Trivonovich, Michael R; Powell, Alexis R; Kumins, Norman; Tarr, Robert; Kashyap, Vikram S

    2018-04-01

    The decision to intervene for internal carotid stenosis often depends on the degree of stenosis seen on duplex ultrasound (US). The aim of this study is to compare the diagnostic accuracy of two criteria: modified University of Washington (UW) and 2003 Carotid Consensus Panel (CCP). All patients undergoing US in an accredited (IAC) vascular laboratory from January 2010 to June 2015 were reviewed ( n=18,772 US exams). Patients receiving a neck computed tomography angiography (CTA) within 6 months of the US were included in the study ( n=254). The degree of stenosis was determined by UW/CCP criteria and confirmed on CTA images using North American Symptomatic Carotid Endarterectomy Trial (NASCET)/European Carotid Surgery Trial (ECST) schema. Kappa analysis with 95% confidence intervals (CIs) were utilized to determine duplex-CTA agreement. A total of 417 carotid arteries from 221 patients were assessed in this study. The modified UW criteria accurately classified 266 (63.9%, kappa = 0.321, 95% CI 0.255 to 0.386) cases according to NASCET-derived measurements. The sensitivity, specificity, and accuracy at ≥ 60% stenosis were 65.7%, 81.3%, and 81.9%. The CCP criteria resulted in 296 (70.9%) accurate diagnoses (kappa = 0.359, 95% CI 0.280 to 0.437). At ≥ 70% stenosis, the sensitivity, specificity and accuracy were 38.8%, 91.6%, and 87.1% for NASCET. Comparison of the duplex results to ECST-derived CTA measurements revealed a similar trend (UW 53.1%, κ = 0.301 vs CCP 62.1%, κ = 0.315). The CCP criteria demonstrate a higher concordance rate with measurements taken from CTAs. The CCP criteria may be more sensitive in classifying clinically significant degrees of stenosis without a loss in diagnostic accuracy.

  3. The effect of increasingly stringent diagnostic criteria on sex ...

    African Journals Online (AJOL)

    The male/female ratio rose from 1.6 among those meeting the CATEGO 'broad' criteria for schizophrenia to 3.7 among those satisfying DSM-III criteria. Of 76 women meeting the former criteria, 53 were excluded by the latter, the majority rediagnosed as affective or schizo-affective psychosis. Consequently, although women ...

  4. Accuracy of Carotid Duplex Criteria in Diagnosis of Significant Carotid Stenosis in Asian Patients.

    Science.gov (United States)

    Dharmasaroja, Pornpatr A; Uransilp, Nattaphol; Watcharakorn, Arvemas; Piyabhan, Pritsana

    2018-03-01

    Extracranial carotid stenosis can be diagnosed by velocity criteria of carotid duplex. Whether they are accurately applied to define severity of internal carotid artery (ICA) stenosis in Asian patients needs to be proved. The purpose of this study was to evaluate the accuracy of 2 carotid duplex velocity criteria in defining significant carotid stenosis. Carotid duplex studies and magnetic resonance angiography were reviewed. Criteria 1 was recommended by the Society of Radiologists in Ultrasound; moderate stenosis (50%-69%): peak systolic velocity (PSV) 125-230 cm/s, diastolic velocity (DV) 40-100 cm/s; severe stenosis (>70%): PSV greater than 230 cm/s, DV greater than 100 cm/s. Criteria 2 used PSV greater than 140 cm/s, DV less than 110 cm/s to define moderate stenosis (50%-75%) and PSV greater than 140 cm/s, DV greater than 110 cm/s for severe stenosis (76%-95%). A total of 854 ICA segments were reviewed. There was moderate stenosis in 72 ICAs, severe stenosis in 50 ICAs, and occlusion in 78 ICAs. Criteria 2 had slightly lower sensitivity, whereas higher specificity and accuracy than criteria 1 were observed in detecting moderate stenosis (criteria 1: sensitivity 95%, specificity 83%, accuracy 84%; criteria 2: sensitivity 92%, specificity 92%, and accuracy 92%). However, in detection of severe ICA stenosis, no significant difference in sensitivity, specificity, and accuracy was found (criteria 1: sensitivity 82%, specificity 99.57%, accuracy 98%; criteria 2: sensitivity 86%, specificity 99.68%, and accuracy 99%). In the subgroup of moderate stenosis, the criteria using ICA PSV greater than 140 cm/s had higher specificity and accuracy than the criteria using ICA PSV 125-230 cm/s. However, there was no significant difference in detection of severe stenosis or occlusion of ICA. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  5. Diagnostic accuracy of the Salzburg EEG criteria for non-convulsive status epilepticus

    DEFF Research Database (Denmark)

    Leitinger, Markus; Trinka, Eugen; Gardella, Elena

    2016-01-01

    Background Several EEG criteria have been proposed for diagnosis of non-convulsive status epilepticus (NCSE), but none have been clinically validated. We aimed to assess the diagnostic accuracy of the EEG criteria proposed by a panel of experts at the fourth London–Innsbruck Colloquium on Status...... Epilepticus in Salzburg, 2013 (henceforth called the Salzburg criteria). Methods We did a retrospective, diagnostic accuracy study using EEG recordings from patients admitted for neurological symptoms or signs to three centres in two countries (Danish Epilepsy Centre, Dianalund, Denmark; Aarhus University...

  6. Accuracy criteria recommended for the certification of gravimetric coal-mine-dust samplers

    International Nuclear Information System (INIS)

    Bowman, J.D.; Bartley, D.L.; Breuer, G.M.; Doemeny, L.J.; Murdock, D.J.

    1984-07-01

    Procedures for testing bias and precision of gravimetric coal-mine-dust sampling units are reviewed. Performance criteria for NIOSH certification of personal coal-mine dust samplers are considered. The NIOSH criterion is an accuracy of 25% at the 95% confidence interval. Size distributions of coal-mine-dust are discussed. Methods for determining size distributions are described. Sampling and sizing methods are considered. Cyclone parameter estimation is discussed. Bias computations for general sampling units are noted. Recommended procedures for evaluating bias and precision of gravimetric coal mine dust personal samplers are given. The authors conclude that when cyclones are operated at lower rates, the NIOSH accuracy criteria can be met

  7. Comparison of urine iodine/creatinine ratio between patients following stringent and less stringent low iodine diet for radioiodine remnant ablation of thyroid cancer

    International Nuclear Information System (INIS)

    Roh, Jee Ho; Kim, Byung Il; Ha, Ji Su; Chang, Sei Joong; Shin, Hye Young; Choi, Joon Hyuk; Kim, Do Min; Kim, Chong Soon

    2006-01-01

    A low iodine diet (LID) for 1 ∼ 2 weeks is recommended for patients who undergoing radioiodine remnant ablation. However, the LID educations for patients are different among centers because there is no concrete recommendation for protocol of LID. In this investigation, we compared two representative types of LID protocols performed in several centers in Korea using urine iodine to creatinine tatio (urine I/Cr). From 2006, April to June, patients referred to our center for radioiodine remnant ablation of thyroid cancer from several local hospitals which had different LID protocols were included. We divided into two groups, stringent LID for 1 week and less stringent LID for 2 weeks, then measured their urine I/Cr ratio with spot urine when patients were admitted to the hospital. Total 27 patients were included in this investigation (M:F = 1:26; 13 in one-week stringent LID; 14 in two-week less stringent LID). Average of urine I/Cr ratio was 127.87 ± 78.52 μ g/g in stringent LID for 1 week, and 289.75 ± 188.24 μ g/g in less stringent LID for 2 weeks. It was significantly lower in stringent LID for 1 week group (ρ = 0.008). The number of patients whose urine I/Cr ratios were below 100 μ g/g was 6 of 13 in stringent LID for 1 week group, and 3 of 14 in less stringent LID for 2 weeks group. Stringent LID for 1 week resulted in better urinary I/Cr ratio in our investigation compared with the other protocol. However it still resulted in plenty of inadequate range of I/Cr ratio, so more stringent protocol such as stringent LID for 2 weeks is expected more desirable

  8. Acquisition of decision making criteria: reward rate ultimately beats accuracy.

    Science.gov (United States)

    Balci, Fuat; Simen, Patrick; Niyogi, Ritwik; Saxe, Andrew; Hughes, Jessica A; Holmes, Philip; Cohen, Jonathan D

    2011-02-01

    Speed-accuracy trade-offs strongly influence the rate of reward that can be earned in many decision-making tasks. Previous reports suggest that human participants often adopt suboptimal speed-accuracy trade-offs in single session, two-alternative forced-choice tasks. We investigated whether humans acquired optimal speed-accuracy trade-offs when extensively trained with multiple signal qualities. When performance was characterized in terms of decision time and accuracy, our participants eventually performed nearly optimally in the case of higher signal qualities. Rather than adopting decision criteria that were individually optimal for each signal quality, participants adopted a single threshold that was nearly optimal for most signal qualities. However, setting a single threshold for different coherence conditions resulted in only negligible decrements in the maximum possible reward rate. Finally, we tested two hypotheses regarding the possible sources of suboptimal performance: (1) favoring accuracy over reward rate and (2) misestimating the reward rate due to timing uncertainty. Our findings provide support for both hypotheses, but also for the hypothesis that participants can learn to approach optimality. We find specifically that an accuracy bias dominates early performance, but diminishes greatly with practice. The residual discrepancy between optimal and observed performance can be explained by an adaptive response to uncertainty in time estimation.

  9. Analytical Performance Requirements for Systems for Self-Monitoring of Blood Glucose With Focus on System Accuracy: Relevant Differences Among ISO 15197:2003, ISO 15197:2013, and Current FDA Recommendations.

    Science.gov (United States)

    Freckmann, Guido; Schmid, Christina; Baumstark, Annette; Rutschmann, Malte; Haug, Cornelia; Heinemann, Lutz

    2015-07-01

    In the European Union (EU), the ISO (International Organization for Standardization) 15197 standard is applicable for the evaluation of systems for self-monitoring of blood glucose (SMBG) before the market approval. In 2013, a revised version of this standard was published. Relevant revisions in the analytical performance requirements are the inclusion of the evaluation of influence quantities, for example, hematocrit, and some changes in the testing procedures for measurement precision and system accuracy evaluation, for example, number of test strip lots. Regarding system accuracy evaluation, the most important change is the inclusion of more stringent accuracy criteria. In 2014, the Food and Drug Administration (FDA) in the United States published their own guidance document for the premarket evaluation of SMBG systems with even more stringent system accuracy criteria than stipulated by ISO 15197:2013. The establishment of strict accuracy criteria applicable for the premarket evaluation is a possible approach to further improve the measurement quality of SMBG systems. However, the system accuracy testing procedure is quite complex, and some critical aspects, for example, systematic measurement difference between the reference measurement procedure and a higher-order procedure, may potentially limit the apparent accuracy of a given system. Therefore, the implementation of a harmonized reference measurement procedure for which traceability to standards of higher order is verified through an unbroken, documented chain of calibrations is desirable. In addition, the establishment of regular and standardized post-marketing evaluations of distributed test strip lots should be considered as an approach toward an improved measurement quality of available SMBG systems. © 2015 Diabetes Technology Society.

  10. An index with improved diagnostic accuracy for the diagnosis of Crohn's disease derived from the Lennard-Jones criteria.

    Science.gov (United States)

    Reinisch, S; Schweiger, K; Pablik, E; Collet-Fenetrier, B; Peyrin-Biroulet, L; Alfaro, I; Panés, J; Moayyedi, P; Reinisch, W

    2016-09-01

    The Lennard-Jones criteria are considered the gold standard for diagnosing Crohn's disease (CD) and include the items granuloma, macroscopic discontinuity, transmural inflammation, fibrosis, lymphoid aggregates and discontinuous inflammation on histology. The criteria have never been subjected to a formal validation process. To develop a validated and improved diagnostic index based on the items of Lennard-Jones criteria. Included were 328 adult patients with long-standing CD (median disease duration 10 years) from three centres and classified as 'established', 'probable' or 'non-CD' by Lennard-Jones criteria at time of diagnosis. Controls were patients with ulcerative colitis (n = 170). The performance of each of the six diagnostic items of Lennard-Jones criteria was modelled by logistic regression and a new index based on stepwise backward selection and cut-offs was developed. The diagnostic value of the new index was analysed by comparing sensitivity, specificity and accuracy vs. Lennard-Jones criteria. By Lennard-Jones criteria 49% (n = 162) of CD patients would have been diagnosed as 'non-CD' at time of diagnosis (sensitivity/specificity/accuracy, 'established' CD: 0.34/0.99/0.67; 'probable' CD: 0.51/0.95/0.73). A new index was derived from granuloma, fibrosis, transmural inflammation and macroscopic discontinuity, but excluded lymphoid aggregates and discontinuous inflammation on histology. Our index provided improved diagnostic accuracy for 'established' and 'probable' CD (sensitivity/specificity/accuracy, 'established' CD: 0.45/1/0.72; 'probable' CD: 0.8/0.85/0.82), including the subgroup isolated colonic CD ('probable' CD, new index: 0.73/0.85/0.79; Lennard-Jones criteria: 0.43/0.95/0.69). We developed an index based on items of Lennard-Jones criteria providing improved diagnostic accuracy for the differential diagnosis between CD and UC. © 2016 John Wiley & Sons Ltd.

  11. New Criteria for Assessing the Accuracy of Blood Glucose Monitors meeting, October 28, 2011.

    Science.gov (United States)

    Walsh, John; Roberts, Ruth; Vigersky, Robert A; Schwartz, Frank

    2012-03-01

    Glucose meters (GMs) are routinely used for self-monitoring of blood glucose by patients and for point-of-care glucose monitoring by health care providers in outpatient and inpatient settings. Although widely assumed to be accurate, numerous reports of inaccuracies with resulting morbidity and mortality have been noted. Insulin dosing errors based on inaccurate GMs are most critical. On October 28, 2011, the Diabetes Technology Society invited 45 diabetes technology clinicians who were attending the 2011 Diabetes Technology Meeting to participate in a closed-door meeting entitled New Criteria for Assessing the Accuracy of Blood Glucose Monitors. This report reflects the opinions of most of the attendees of that meeting. The Food and Drug Administration (FDA), the public, and several medical societies are currently in dialogue to establish a new standard for GM accuracy. This update to the FDA standard is driven by improved meter accuracy, technological advances (pumps, bolus calculators, continuous glucose monitors, and insulin pens), reports of hospital and outpatient deaths, consumer complaints about inaccuracy, and research studies showing that several approved GMs failed to meet FDA or International Organization for Standardization standards in postapproval testing. These circumstances mandate a set of new GM standards that appropriately match the GMs' analytical accuracy to the clinical accuracy required for their intended use, as well as ensuring their ongoing accuracy following approval. The attendees of the New Criteria for Assessing the Accuracy of Blood Glucose Monitors meeting proposed a graduated standard and other methods to improve GM performance, which are discussed in this meeting report. © 2012 Diabetes Technology Society.

  12. 40 CFR 80.584 - What are the precision and accuracy criteria for approval of test methods for determining the...

    Science.gov (United States)

    2010-07-01

    ... criteria for approval of test methods for determining the sulfur content of motor vehicle diesel fuel, NRLM....584 What are the precision and accuracy criteria for approval of test methods for determining the... available gravimetric sulfur standard in the range of 1-10 ppm sulfur shall not differ from the accepted...

  13. Circuitry linking the Csr and stringent response global regulatory systems.

    Science.gov (United States)

    Edwards, Adrianne N; Patterson-Fortin, Laura M; Vakulskas, Christopher A; Mercante, Jeffrey W; Potrykus, Katarzyna; Vinella, Daniel; Camacho, Martha I; Fields, Joshua A; Thompson, Stuart A; Georgellis, Dimitris; Cashel, Michael; Babitzke, Paul; Romeo, Tony

    2011-06-01

    CsrA protein regulates important cellular processes by binding to target mRNAs and altering their translation and/or stability. In Escherichia coli, CsrA binds to sRNAs, CsrB and CsrC, which sequester CsrA and antagonize its activity. Here, mRNAs for relA, spoT and dksA of the stringent response system were found among 721 different transcripts that copurified with CsrA. Many of the transcripts that copurified with CsrA were previously determined to respond to ppGpp and/or DksA. We examined multiple regulatory interactions between the Csr and stringent response systems. Most importantly, DksA and ppGpp robustly activated csrB/C transcription (10-fold), while they modestly activated csrA expression. We propose that CsrA-mediated regulation is relieved during the stringent response. Gel shift assays confirmed high affinity binding of CsrA to relA mRNA leader and weaker interactions with dksA and spoT. Reporter fusions, qRT-PCR and immunoblotting showed that CsrA repressed relA expression, and (p)ppGpp accumulation during stringent response was enhanced in a csrA mutant. CsrA had modest to negligible effects on dksA and spoT expression. Transcription of dksA was negatively autoregulated via a feedback loop that tended to mask CsrA effects. We propose that the Csr system fine-tunes the stringent response and discuss biological implications of the composite circuitry. © Published 2011. This article is a US Government work and is in the public domain in the USA.

  14. System Accuracy Evaluation of Four Systems for Self-Monitoring of Blood Glucose Following ISO 15197 Using a Glucose Oxidase and a Hexokinase-Based Comparison Method.

    Science.gov (United States)

    Link, Manuela; Schmid, Christina; Pleus, Stefan; Baumstark, Annette; Rittmeyer, Delia; Haug, Cornelia; Freckmann, Guido

    2015-04-14

    The standard ISO (International Organization for Standardization) 15197 is widely accepted for the accuracy evaluation of systems for self-monitoring of blood glucose (SMBG). Accuracy evaluation was performed for 4 SMBG systems (Accu-Chek Aviva, ContourXT, GlucoCheck XL, GlucoMen LX PLUS) with 3 test strip lots each. To investigate a possible impact of the comparison method on system accuracy data, 2 different established methods were used. The evaluation was performed in a standardized manner following test procedures described in ISO 15197:2003 (section 7.3). System accuracy was assessed by applying ISO 15197:2003 and in addition ISO 15197:2013 criteria (section 6.3.3). For each system, comparison measurements were performed with a glucose oxidase (YSI 2300 STAT Plus glucose analyzer) and a hexokinase (cobas c111) method. All 4 systems fulfilled the accuracy requirements of ISO 15197:2003 with the tested lots. More stringent accuracy criteria of ISO 15197:2013 were fulfilled by 3 systems (Accu-Chek Aviva, ContourXT, GlucoMen LX PLUS) when compared to the manufacturer's comparison method and by 2 systems (Accu-Chek Aviva, ContourXT) when compared to the alternative comparison method. All systems showed lot-to-lot variability to a certain degree; 2 systems (Accu-Chek Aviva, ContourXT), however, showed only minimal differences in relative bias between the 3 evaluated lots. In this study, all 4 systems complied with the evaluated test strip lots with accuracy criteria of ISO 15197:2003. Applying ISO 15197:2013 accuracy limits, differences in the accuracy of the tested systems were observed, also demonstrating that the applied comparison method/system and the lot-to-lot variability can have a decisive influence on accuracy data obtained for a SMBG system. © 2015 Diabetes Technology Society.

  15. Is ionizing radiation regulated more stringently than chemical carcinogens

    International Nuclear Information System (INIS)

    Travis, C.C.; Pack, S.R.; Hattemer-Frey, H.A.

    1989-01-01

    It is widely believed that United States government agencies regulate exposure to ionizing radiation more stringently than exposure to chemical carcinogens. It is difficult to verify this perception, however, because chemical carcinogens and ionizing radiation are regulated using vastly different strategies. Chemical carcinogens are generally regulated individually. Regulators consider the risk of exposure to one chemical rather than the cumulative radiation exposure from all sources. Moreover, standards for chemical carcinogens are generally set in terms of quantities released or resultant environmental concentrations, while standards for ionizing radiation are set in terms of dose to the human body. Since chemicals and ionizing radiation cannot be compared on the basis of equal dose to the exposed individual, standards regulating chemicals and ionizing radiation cannot be compared directly. It is feasible, however, to compare the two sets of standards on the basis of equal risk to the exposed individual, assuming that standards for chemicals and ionizing radiation are equivalent if estimated risk levels are equitable. This paper compares risk levels associated with current standards for ionizing radiation and chemical carcinogens. The authors do not attempt to determine whether either type of risk is regulated too stringently or not stringently enough but endeavor only to ascertain if ionizing radiation is actually regulated more strictly than chemical carcinogens

  16. Diagnostic accuracy of physical examination tests of the ankle/foot complex: a systematic review.

    Science.gov (United States)

    Schwieterman, Braun; Haas, Deniele; Columber, Kirby; Knupp, Darren; Cook, Chad

    2013-08-01

    Orthopedic special tests of the ankle/foot complex are routinely used during the physical examination process in order to help diagnose ankle/lower leg pathologies. The purpose of this systematic review was to investigate the diagnostic accuracy of ankle/lower leg special tests. A search of the current literature was conducted using PubMed, CINAHL, SPORTDiscus, ProQuest Nursing and Allied Health Sources, Scopus, and Cochrane Library. Studies were eligible if they included the following: 1) a diagnostic clinical test of musculoskeletal pathology in the ankle/foot complex, 2) description of the clinical test or tests, 3) a report of the diagnostic accuracy of the clinical test (e.g. sensitivity and specificity), and 4) an acceptable reference standard for comparison. The quality of included studies was determined by two independent reviewers using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Nine diagnostic accuracy studies met the inclusion criteria for this systematic review; analyzing a total of 16 special tests of the ankle/foot complex. After assessment using the QUADAS-2, only one study had low risk of bias and low concerns regarding applicability. Most ankle/lower leg orthopedic special tests are confirmatory in nature and are best utilized at the end of the physical examination. Most of the studies included in this systematic review demonstrate notable biases, which suggest that results and recommendations in this review should be taken as a guide rather than an outright standard. There is need for future research with more stringent study design criteria so that more accurate diagnostic power of ankle/lower leg special tests can be determined. 3a.

  17. Proposed Diagnostic Criteria for Smartphone Addiction.

    Science.gov (United States)

    Lin, Yu-Hsuan; Chiang, Chih-Lin; Lin, Po-Hsien; Chang, Li-Ren; Ko, Chih-Hung; Lee, Yang-Han; Lin, Sheng-Hsuan

    2016-01-01

    Global smartphone penetration has led to unprecedented addictive behaviors. The aims of this study are to develop diagnostic criteria of smartphone addiction and to examine the discriminative ability and the validity of the diagnostic criteria. We developed twelve candidate criteria for characteristic symptoms of smartphone addiction and four criteria for functional impairment caused by excessive smartphone use. The participants consisted of 281 college students. Each participant was systematically assessed for smartphone-using behaviors by psychiatrist's structured diagnostic interview. The sensitivity, specificity, and diagnostic accuracy of the candidate symptom criteria were analyzed with reference to the psychiatrists' clinical global impression. The optimal model selection with its cutoff point of the diagnostic criteria differentiating the smartphone addicted subjects from non-addicted subjects was then determined by the best diagnostic accuracy. Six symptom criteria model with optimal cutoff point were determined based on the maximal diagnostic accuracy. The proposed smartphone addiction diagnostic criteria consisted of (1) six symptom criteria, (2) four functional impairment criteria and (3) exclusion criteria. Setting three symptom criteria as the cutoff point resulted in the highest diagnostic accuracy (84.3%), while the sensitivity and specificity were 79.4% and 87.5%, respectively. We suggested determining the functional impairment by two or more of the four domains considering the high accessibility and penetration of smartphone use. The diagnostic criteria of smartphone addiction demonstrated the core symptoms "impaired control" paralleled with substance related and addictive disorders. The functional impairment involved multiple domains provide a strict standard for clinical assessment.

  18. Proposed Diagnostic Criteria for Smartphone Addiction.

    Directory of Open Access Journals (Sweden)

    Yu-Hsuan Lin

    Full Text Available Global smartphone penetration has led to unprecedented addictive behaviors. The aims of this study are to develop diagnostic criteria of smartphone addiction and to examine the discriminative ability and the validity of the diagnostic criteria.We developed twelve candidate criteria for characteristic symptoms of smartphone addiction and four criteria for functional impairment caused by excessive smartphone use. The participants consisted of 281 college students. Each participant was systematically assessed for smartphone-using behaviors by psychiatrist's structured diagnostic interview. The sensitivity, specificity, and diagnostic accuracy of the candidate symptom criteria were analyzed with reference to the psychiatrists' clinical global impression. The optimal model selection with its cutoff point of the diagnostic criteria differentiating the smartphone addicted subjects from non-addicted subjects was then determined by the best diagnostic accuracy.Six symptom criteria model with optimal cutoff point were determined based on the maximal diagnostic accuracy. The proposed smartphone addiction diagnostic criteria consisted of (1 six symptom criteria, (2 four functional impairment criteria and (3 exclusion criteria. Setting three symptom criteria as the cutoff point resulted in the highest diagnostic accuracy (84.3%, while the sensitivity and specificity were 79.4% and 87.5%, respectively. We suggested determining the functional impairment by two or more of the four domains considering the high accessibility and penetration of smartphone use.The diagnostic criteria of smartphone addiction demonstrated the core symptoms "impaired control" paralleled with substance related and addictive disorders. The functional impairment involved multiple domains provide a strict standard for clinical assessment.

  19. THREE THEORIES OF COGNITIVE REPRESENTATION AND CRITERIA FOR EVALUATING TRAINING EFFECTS

    NARCIS (Netherlands)

    Tomic, W.; Kingma, J.

    2008-01-01

    The development of cognitive representation is the main theme of the three classic theories on how children learn new concepts (Piaget, Bruner, Vygotsky). However, these theories do not agree on evaluation standards for training effectiveness. According to Piaget, it is only when stringent criteria

  20. Orphan Toxin OrtT (YdcX) of Escherichia coli Reduces Growth during the Stringent Response

    Science.gov (United States)

    2015-01-29

    antimicrobials trimethoprim and sulfamethoxazole; these antimicrobials induce the stringent response by inhibiting tetrahydrofolate synthesis...in the presence of both antimicrobials trimethoprim and sulfamethoxazole; these antimicrobials induce the stringent response by inhibiting...level [20]. Toxins 2015, 7 301 Despite these difficulties in determining physiological roles, TA systems are clearly phage inhibition systems

  1. Perspectives on the revised Ghent criteria for the diagnosis of Marfan syndrome

    Science.gov (United States)

    von Kodolitsch, Yskert; De Backer, Julie; Schüler, Helke; Bannas, Peter; Behzadi, Cyrus; Bernhardt, Alexander M; Hillebrand, Mathias; Fuisting, Bettina; Sheikhzadeh, Sara; Rybczynski, Meike; Kölbel, Tilo; Püschel, Klaus; Blankenberg, Stefan; Robinson, Peter N

    2015-01-01

    Three international nosologies have been proposed for the diagnosis of Marfan syndrome (MFS): the Berlin nosology in 1988; the Ghent nosology in 1996 (Ghent-1); and the revised Ghent nosology in 2010 (Ghent-2). We reviewed the literature and discussed the challenges and concepts of diagnosing MFS in adults. Ghent-1 proposed more stringent clinical criteria, which led to the confirmation of MFS in only 32%–53% of patients formerly diagnosed with MFS according to the Berlin nosology. Conversely, both the Ghent-1 and Ghent-2 nosologies diagnosed MFS, and both yielded similar frequencies of MFS in persons with a causative FBN1 mutation (90% for Ghent-1 versus 92% for Ghent-2) and in persons not having a causative FBN1 mutation (15% versus 13%). Quality criteria for diagnostic methods include objectivity, reliability, and validity. However, the nosology-based diagnosis of MFS lacks a diagnostic reference standard and, hence, quality criteria such as sensitivity, specificity, or accuracy cannot be assessed. Medical utility of diagnosis implies congruency with the historical criteria of MFS, as well as with information about the etiology, pathogenesis, diagnostic triggers, prognostic triggers, and potential complications of MFS. In addition, social and psychological utilities of diagnostic criteria include acceptance by patients, patient organizations, clinicians and scientists, practicability, costs, and the reduction of anxiety. Since the utility of a diagnosis or exclusion of MFS is context-dependent, prioritization of utilities is a strategic decision in the process of nosology development. Screening tests for MFS should be used to identify persons with MFS. To confirm the diagnosis of MFS, Ghent-1 and Ghent-2 perform similarly, but Ghent-2 is easier to use. To maximize the utility of the diagnostic criteria of MFS, a fair and transparent process of nosology development is essential. PMID:26124674

  2. Delirium diagnosis defined by cluster analysis of symptoms versus diagnosis by DSM and ICD criteria: diagnostic accuracy study.

    Science.gov (United States)

    Sepulveda, Esteban; Franco, José G; Trzepacz, Paula T; Gaviria, Ana M; Meagher, David J; Palma, José; Viñuelas, Eva; Grau, Imma; Vilella, Elisabet; de Pablo, Joan

    2016-05-26

    Information on validity and reliability of delirium criteria is necessary for clinicians, researchers, and further developments of DSM or ICD. We compare four DSM and ICD delirium diagnostic criteria versions, which were developed by consensus of experts, with a phenomenology-based natural diagnosis delineated using cluster analysis of delirium features in a sample with a high prevalence of dementia. We also measured inter-rater reliability of each system when applied by two evaluators from distinct disciplines. Cross-sectional analysis of 200 consecutive patients admitted to a skilled nursing facility, independently assessed within 24-48 h after admission with the Delirium Rating Scale-Revised-98 (DRS-R98) and for DSM-III-R, DSM-IV, DSM-5, and ICD-10 criteria for delirium. Cluster analysis (CA) delineated natural delirium and nondelirium reference groups using DRS-R98 items and then diagnostic systems' performance were evaluated against the CA-defined groups using logistic regression and crosstabs for discriminant analysis (sensitivity, specificity, percentage of subjects correctly classified by each diagnostic system and their individual criteria, and performance for each system when excluding each individual criterion are reported). Kappa Index (K) was used to report inter-rater reliability for delirium diagnostic systems and their individual criteria. 117 (58.5 %) patients had preexisting dementia according to the Informant Questionnaire on Cognitive Decline in the Elderly. CA delineated 49 delirium subjects and 151 nondelirium. Against these CA groups, delirium diagnosis accuracy was highest using DSM-III-R (87.5 %) followed closely by DSM-IV (86.0 %), ICD-10 (85.5 %) and DSM-5 (84.5 %). ICD-10 had the highest specificity (96.0 %) but lowest sensitivity (53.1 %). DSM-III-R had the best sensitivity (81.6 %) and the best sensitivity-specificity balance. DSM-5 had the highest inter-rater reliability (K =0.73) while DSM-III-R criteria were the least

  3. Criteria to Extract High-Quality Protein Data Bank Subsets for Structure Users.

    Science.gov (United States)

    Carugo, Oliviero; Djinović-Carugo, Kristina

    2016-01-01

    It is often necessary to build subsets of the Protein Data Bank to extract structural trends and average values. For this purpose it is mandatory that the subsets are non-redundant and of high quality. The first problem can be solved relatively easily at the sequence level or at the structural level. The second, on the contrary, needs special attention. It is not sufficient, in fact, to consider the crystallographic resolution and other feature must be taken into account: the absence of strings of residues from the electron density maps and from the files deposited in the Protein Data Bank; the B-factor values; the appropriate validation of the structural models; the quality of the electron density maps, which is not uniform; and the temperature of the diffraction experiments. More stringent criteria produce smaller subsets, which can be enlarged with more tolerant selection criteria. The incessant growth of the Protein Data Bank and especially of the number of high-resolution structures is allowing the use of more stringent selection criteria, with a consequent improvement of the quality of the subsets of the Protein Data Bank.

  4. Stringent DDI-based prediction of H. sapiens-M. tuberculosis H37Rv protein-protein interactions.

    Science.gov (United States)

    Zhou, Hufeng; Rezaei, Javad; Hugo, Willy; Gao, Shangzhi; Jin, Jingjing; Fan, Mengyuan; Yong, Chern-Han; Wozniak, Michal; Wong, Limsoon

    2013-01-01

    H. sapiens-M. tuberculosis H37Rv protein-protein interaction (PPI) data are very important information to illuminate the infection mechanism of M. tuberculosis H37Rv. But current H. sapiens-M. tuberculosis H37Rv PPI data are very scarce. This seriously limits the study of the interaction between this important pathogen and its host H. sapiens. Computational prediction of H. sapiens-M. tuberculosis H37Rv PPIs is an important strategy to fill in the gap. Domain-domain interaction (DDI) based prediction is one of the frequently used computational approaches in predicting both intra-species and inter-species PPIs. However, the performance of DDI-based host-pathogen PPI prediction has been rather limited. We develop a stringent DDI-based prediction approach with emphasis on (i) differences between the specific domain sequences on annotated regions of proteins under the same domain ID and (ii) calculation of the interaction strength of predicted PPIs based on the interacting residues in their interaction interfaces. We compare our stringent DDI-based approach to a conventional DDI-based approach for predicting PPIs based on gold standard intra-species PPIs and coherent informative Gene Ontology terms assessment. The assessment results show that our stringent DDI-based approach achieves much better performance in predicting PPIs than the conventional approach. Using our stringent DDI-based approach, we have predicted a small set of reliable H. sapiens-M. tuberculosis H37Rv PPIs which could be very useful for a variety of related studies. We also analyze the H. sapiens-M. tuberculosis H37Rv PPIs predicted by our stringent DDI-based approach using cellular compartment distribution analysis, functional category enrichment analysis and pathway enrichment analysis. The analyses support the validity of our prediction result. Also, based on an analysis of the H. sapiens-M. tuberculosis H37Rv PPI network predicted by our stringent DDI-based approach, we have discovered some

  5. Derivation and validation of the Systemic Lupus International Collaborating Clinics classification criteria for systemic lupus erythematosus

    DEFF Research Database (Denmark)

    Petri, Michelle; Orbai, Ana-Maria; Alarcón, Graciela S

    2012-01-01

    The Systemic Lupus International Collaborating Clinics (SLICC) group revised and validated the American College of Rheumatology (ACR) systemic lupus erythematosus (SLE) classification criteria in order to improve clinical relevance, meet stringent methodology requirements, and incorporate new...

  6. Electricity versus hydrogen for passenger cars under stringent climate change control

    NARCIS (Netherlands)

    Rösler, H.; van der Zwaan, B.; Keppo, I.; Bruggink, J.

    2014-01-01

    In this article we analyze how passenger car transportation in Europe may change this century under permanent high oil prices and stringent climate control policy. We focus on electricity and hydrogen as principal candidate energy carriers, because these two options are increasingly believed to

  7. Sensitivity and Specificity of Proposed DSM-5 Criteria for Autism Spectrum Disorder in Toddlers

    Science.gov (United States)

    Barton, Marianne L.; Robins, Diana L.; Jashar, Dasal; Brennan, Laura; Fein, Deborah

    2013-01-01

    Autism spectrum disorder (ASD) diagnosis is based on behavioral presentation; changes in conceptual models or defining behaviors may significantly impact diagnosis and uptake of ASD-specific interventions. The literature examining impact of DSM-5 criteria is equivocal. Toddlers may be especially vulnerable to the stringent requirements of…

  8. Diagnostic criteria for headache attributed to temporomandibular disorders

    DEFF Research Database (Denmark)

    Schiffman, Eric; Ohrbach, Richard; List, Thomas

    2012-01-01

    We assessed and compared the diagnostic accuracy of two sets of diagnostic criteria for headache secondary to temporomandibular disorders (TMD).......We assessed and compared the diagnostic accuracy of two sets of diagnostic criteria for headache secondary to temporomandibular disorders (TMD)....

  9. Setting apart the affected: the use of behavioral criteria in animal models of post traumatic stress disorder.

    Science.gov (United States)

    Cohen, Hagit; Zohar, Joseph; Matar, Michael A; Zeev, Kaplan; Loewenthal, Uri; Richter-Levin, Gal

    2004-11-01

    Post-traumatic stress disorder (PTSD) affects about 20-30% of exposed individuals. Clinical studies of PTSD generally employ stringent criteria for inclusion in study populations, and yet in animal studies the data collection and analysis are generally expressed as a function of exposed vs nonexposed populations, regardless of individual variation in response. Prior data support an approach to animal models analogous to inclusion criteria in clinical studies. This series of studies sought to assess prevalence rates of maladaptive vs adaptive responses determined according to a more stringent approach to the concept of inclusion/exclusion criteria (cutoff behavioral criteria-CBC), consisting of two successive behavioral tests (elevated plus maze and acoustic startle response tests). The rats were exposed to stressors in two different paradigms; exposure to a predator and underwater trauma. The prevalence rates of maladaptive responses to stress in these two distinct models dropped over time from 90% in the acute phase to 25% enduring/maladaptive response at 7 days, to remain constant over 30 days. As setting the affected individuals apart from the unaffected approximates clinical studies, it might also help to clarify some of the pending issues in PTSD research.

  10. Characteristics of radioactive waste forms conditioned for storage and disposal: Guidance for the development of waste acceptance criteria

    International Nuclear Information System (INIS)

    1983-04-01

    This report attempts to review the characteristics of the individual components of the waste package, i.e. the waste form and the container, in order to formulate, where appropriate, quidelines for the development of practical waste acceptance criteria. Primarily the criteria for disposal are considered, but if more stringent criteria are expected to be necessary for storage or transportation prior to the disposal, these will be discussed. The report will also suggest test areas which will aid the development of the final waste acceptance criteria

  11. High Accuracy Transistor Compact Model Calibrations

    Energy Technology Data Exchange (ETDEWEB)

    Hembree, Charles E. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Mar, Alan [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Robertson, Perry J. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    Typically, transistors are modeled by the application of calibrated nominal and range models. These models consists of differing parameter values that describe the location and the upper and lower limits of a distribution of some transistor characteristic such as current capacity. Correspond- ingly, when using this approach, high degrees of accuracy of the transistor models are not expected since the set of models is a surrogate for a statistical description of the devices. The use of these types of models describes expected performances considering the extremes of process or transistor deviations. In contrast, circuits that have very stringent accuracy requirements require modeling techniques with higher accuracy. Since these accurate models have low error in transistor descriptions, these models can be used to describe part to part variations as well as an accurate description of a single circuit instance. Thus, models that meet these stipulations also enable the calculation of quantifi- cation of margins with respect to a functional threshold and uncertainties in these margins. Given this need, new model high accuracy calibration techniques for bipolar junction transis- tors have been developed and are described in this report.

  12. Impact of ANSI 2009 criteria for performance testing in TLD personnel monitoring

    International Nuclear Information System (INIS)

    MeenaI, P.; Rakesh, R.B.; Srivastava, Kshama; KoIambe, D.H.; Sapra, B.K.

    2014-01-01

    External Quality Assurance in TLD Personnel Monitoring Service was initiated in 1985, for periodic performance evaluation of various TLD Laboratories through postal exercise. Presently, all the 16 laboratories involved in Personnel Monitoring Service are covered under QA exercise. Since beginning, American National Standards Institute (ANSI) criteria have been adopted for performance testing in QA exercise. Presently, ANSI 2001 performance criteria along with ISO trumpet curve analysis method are being used for performance evaluation. In 2009, ANSI modified the performance evaluation criteria and this study evaluates its impact and feasibility of implementation of ANSI 2009 criteria in the quality assurance program for personnel monitoring. The performance of some laboratories evaluated using both ANSI 2001 and ANSI 2009 criteria have been discussed. The study shows that the ANSI 2009 criteria is more stringent and encourages even distribution of bias and standard deviation. This can be implemented with suitable modifications for performance evaluation

  13. Critical analysis of the stringent complete response in multiple myeloma: contribution of sFLC and bone marrow clonality.

    Science.gov (United States)

    Martínez-López, Joaquín; Paiva, Bruno; López-Anglada, Lucía; Mateos, María-Victoria; Cedena, Teresa; Vidríales, María-Belén; Sáez-Gómez, María Auxiliadora; Contreras, Teresa; Oriol, Albert; Rapado, Inmaculada; Teruel, Ana-Isabel; Cordón, Lourdes; Blanchard, María Jesús; Bengoechea, Enrique; Palomera, Luis; de Arriba, Felipe; Cueto-Felgueroso, Cecilia; Orfao, Alberto; Bladé, Joan; San Miguel, Jesús F; Lahuerta, Juan José

    2015-08-13

    Stringent complete response (sCR) criteria are used in multiple myeloma as a deeper response category compared with CR, but prospective validation is lacking, it is not always clear how evaluation of clonality is performed, and is it not known what the relative clinical influence is of the serum free light chain ratio (sFLCr) and bone marrow (BM) clonality to define more sCR. To clarify this controversy, we focused on 94 patients that reached CR, of which 69 (73%) also fulfilled the sCR criteria. Patients with sCR displayed slightly longer time to progression (median, 62 vs 53 months, respectively; P = .31). On analyzing this contribution to the prognosis of sFLCr or clonality, it was found that the sFLCr does not identify patients in CR at distinct risk; by contrast, low-sensitive multiparametric flow cytometry (MFC) immunophenotyping (2 colors), which is equivalent to immunohistochemistry, identifies a small number of patients (5 cases) with high residual tumor burden and dismal outcome; nevertheless, using traditional 4-color MFC, persistent clonal BM disease was detectable in 36% of patients, who, compared with minimal residual disease-negative cases, had a significantly inferior outcome. These results show that the current definition of sCR should be revised. © 2015 by The American Society of Hematology.

  14. Structural characterization of the stringent response related exopolyphosphatase/guanosine pentaphosphate phosphohydrolase protein family

    DEFF Research Database (Denmark)

    Kristensen, Ole; Laurberg, Martin; Liljas, Anders

    2004-01-01

    Exopolyphosphatase/guanosine pentaphosphate phosphohydrolase (PPX/GPPA) enzymes play central roles in the bacterial stringent response induced by starvation. The high-resolution crystal structure of the putative Aquifex aeolicus PPX/GPPA phosphatase from the actin-like ATPase domain superfamily has...

  15. ACCURACY AND RELIABILITY AS CRITERIA OF INFORMATIVENESS IN THE NEWS STORY

    Directory of Open Access Journals (Sweden)

    Melnikova Ekaterina Aleksandrovna

    2014-12-01

    Full Text Available The article clarifies the meaning of the terms accuracy and reliability of the news story, offers a researcher's approach to obtaining objective data that helps to verify linguistic means of accuracy and reliability presence in the informative structure of the text. The accuracy of the news story is defined as a high relevance degree of event reflection through language representation of its constituents; the reliability is viewed as news story originality that is proved by introducing citations and sources of information considered being trustworthy into the text content. Having based the research on an event nominative density identification method, the author composed nominative charts of 115 news story texts, collected at web-sites of BBC and CNN media corporations; distinguished qualitative and quantitative markers of accuracy and reliability in the news story text; confirmed that the accuracy of the news story is achieved with terminological clearness in nominating event constituents in the text, thematic bind between words, presence of onyms that help deeply identify characteristics of the referent event. The reliability of the text is discovered in eyewitness accounts, quotations, and references to the sources being considered as trustworthy. Accurate revision of associations between accuracy and reliability and informing strategies in digital news nets allowed the author to set two variants of information delivery, that differ in their communicative and pragmatic functions: developing (that informs about major and minor details of an event and truncated (which gives some details thus raising the interest to the event and urging a reader to open a full story.

  16. IMPACT OF ENERGY GROUP STRUCTURE ON NUCLEAR DATA TARGET ACCURACY REQUIREMENTS FOR ADVANCED REACTOR SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    G. Palmiotti; M. Salvatores; H. Hiruta

    2011-06-01

    A target accuracy assessment study using both a fine and a broad energy structure has shown that less stringent nuclear data accuracy requirements are needed for the latter energy structure. However, even though a reduction is observed, still the requirements will be very difficult to be met unless integral experiments are also used to reduce nuclear data uncertainties. Target accuracy assessment is the inverse problem of the uncertainty evaluation. To establish priorities and target accuracies on data uncertainty reduction, a formal approach can be adopted by defining target accuracy on design parameters and finding out required accuracy on data in order to meet them. In fact, the unknown uncertainty data requirements can be obtained by solving a minimization problem where the sensitivity coefficients in conjunction with the constraints on the integral parameters provide the needed quantities for finding the solutions.

  17. Synthetic Peptides to Target Stringent Response-Controlled Virulence in a Pseudomonas aeruginosa Murine Cutaneous Infection Model

    Directory of Open Access Journals (Sweden)

    Daniel Pletzer

    2017-09-01

    Full Text Available Microorganisms continuously monitor their surroundings and adaptively respond to environmental cues. One way to cope with various stress-related situations is through the activation of the stringent stress response pathway. In Pseudomonas aeruginosa this pathway is controlled and coordinated by the activity of the RelA and SpoT enzymes that metabolize the small nucleotide secondary messenger molecule (pppGpp. Intracellular ppGpp concentrations are crucial in mediating adaptive responses and virulence. Targeting this cellular stress response has recently been the focus of an alternative approach to fight antibiotic resistant bacteria. Here, we examined the role of the stringent response in the virulence of P. aeruginosa PAO1 and the Liverpool epidemic strain LESB58. A ΔrelA/ΔspoT double mutant showed decreased cytotoxicity toward human epithelial cells, exhibited reduced hemolytic activity, and caused down-regulation of the expression of the alkaline protease aprA gene in stringent response mutants grown on blood agar plates. Promoter fusions of relA or spoT to a bioluminescence reporter gene revealed that both genes were expressed during the formation of cutaneous abscesses in mice. Intriguingly, virulence was attenuated in vivo by the ΔrelA/ΔspoT double mutant, but not the relA mutant nor the ΔrelA/ΔspoT complemented with either gene. Treatment of a cutaneous P. aeruginosa PAO1 infection with anti-biofilm peptides increased animal welfare, decreased dermonecrotic lesion sizes, and reduced bacterial numbers recovered from abscesses, resembling the phenotype of the ΔrelA/ΔspoT infection. It was previously demonstrated by our lab that ppGpp could be targeted by synthetic peptides; here we demonstrated that spoT promoter activity was suppressed during cutaneous abscess formation by treatment with peptides DJK-5 and 1018, and that a peptide-treated relA complemented stringent response double mutant strain exhibited reduced peptide

  18. Relative accuracy of spatial predictive models for lynx Lynx canadensis derived using logistic regression-AIC, multiple criteria evaluation and Bayesian approaches

    Directory of Open Access Journals (Sweden)

    Shelley M. ALEXANDER

    2009-02-01

    Full Text Available We compared probability surfaces derived using one set of environmental variables in three Geographic Information Systems (GIS-based approaches: logistic regression and Akaike’s Information Criterion (AIC, Multiple Criteria Evaluation (MCE, and Bayesian Analysis (specifically Dempster-Shafer theory. We used lynx Lynx canadensis as our focal species, and developed our environment relationship model using track data collected in Banff National Park, Alberta, Canada, during winters from 1997 to 2000. The accuracy of the three spatial models were compared using a contingency table method. We determined the percentage of cases in which both presence and absence points were correctly classified (overall accuracy, the failure to predict a species where it occurred (omission error and the prediction of presence where there was absence (commission error. Our overall accuracy showed the logistic regression approach was the most accurate (74.51%. The multiple criteria evaluation was intermediate (39.22%, while the Dempster-Shafer (D-S theory model was the poorest (29.90%. However, omission and commission error tell us a different story: logistic regression had the lowest commission error, while D-S theory produced the lowest omission error. Our results provide evidence that habitat modellers should evaluate all three error measures when ascribing confidence in their model. We suggest that for our study area at least, the logistic regression model is optimal. However, where sample size is small or the species is very rare, it may also be useful to explore and/or use a more ecologically cautious modelling approach (e.g. Dempster-Shafer that would over-predict, protect more sites, and thereby minimize the risk of missing critical habitat in conservation plans[Current Zoology 55(1: 28 – 40, 2009].

  19. Source localization of rhythmic ictal EEG activity: a study of diagnostic accuracy following STARD criteria.

    Science.gov (United States)

    Beniczky, Sándor; Lantz, Göran; Rosenzweig, Ivana; Åkeson, Per; Pedersen, Birthe; Pinborg, Lars H; Ziebell, Morten; Jespersen, Bo; Fuglsang-Frederiksen, Anders

    2013-10-01

    Although precise identification of the seizure-onset zone is an essential element of presurgical evaluation, source localization of ictal electroencephalography (EEG) signals has received little attention. The aim of our study was to estimate the accuracy of source localization of rhythmic ictal EEG activity using a distributed source model. Source localization of rhythmic ictal scalp EEG activity was performed in 42 consecutive cases fulfilling inclusion criteria. The study was designed according to recommendations for studies on diagnostic accuracy (STARD). The initial ictal EEG signals were selected using a standardized method, based on frequency analysis and voltage distribution of the ictal activity. A distributed source model-local autoregressive average (LAURA)-was used for the source localization. Sensitivity, specificity, and measurement of agreement (kappa) were determined based on the reference standard-the consensus conclusion of the multidisciplinary epilepsy surgery team. Predictive values were calculated from the surgical outcome of the operated patients. To estimate the clinical value of the ictal source analysis, we compared the likelihood ratios of concordant and discordant results. Source localization was performed blinded to the clinical data, and before the surgical decision. Reference standard was available for 33 patients. The ictal source localization had a sensitivity of 70% and a specificity of 76%. The mean measurement of agreement (kappa) was 0.61, corresponding to substantial agreement (95% confidence interval (CI) 0.38-0.84). Twenty patients underwent resective surgery. The positive predictive value (PPV) for seizure freedom was 92% and the negative predictive value (NPV) was 43%. The likelihood ratio was nine times higher for the concordant results, as compared with the discordant ones. Source localization of rhythmic ictal activity using a distributed source model (LAURA) for the ictal EEG signals selected with a standardized method

  20. Validation of proposed diagnostic criteria (the "Budapest Criteria") for Complex Regional Pain Syndrome.

    Science.gov (United States)

    Harden, R Norman; Bruehl, Stephen; Perez, Roberto S G M; Birklein, Frank; Marinus, Johan; Maihofner, Christian; Lubenow, Timothy; Buvanendran, Asokumar; Mackey, Sean; Graciosa, Joseph; Mogilevski, Mila; Ramsden, Christopher; Chont, Melissa; Vatine, Jean-Jacques

    2010-08-01

    Current IASP diagnostic criteria for CRPS have low specificity, potentially leading to overdiagnosis. This validation study compared current IASP diagnostic criteria for CRPS to proposed new diagnostic criteria (the "Budapest Criteria") regarding diagnostic accuracy. Structured evaluations of CRPS-related signs and symptoms were conducted in 113 CRPS-I and 47 non-CRPS neuropathic pain patients. Discriminating between diagnostic groups based on presence of signs or symptoms meeting IASP criteria showed high diagnostic sensitivity (1.00), but poor specificity (0.41), replicating prior work. In comparison, the Budapest clinical criteria retained the exceptional sensitivity of the IASP criteria (0.99), but greatly improved upon the specificity (0.68). As designed, the Budapest research criteria resulted in the highest specificity (0.79), again replicating prior work. Analyses indicated that inclusion of four distinct CRPS components in the Budapest Criteria contributed to enhanced specificity. Overall, results corroborate the validity of the Budapest Criteria and suggest they improve upon existing IASP diagnostic criteria for CRPS. Copyright (c) 2010 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  1. Ten Year Study of the Stringently Defined Otitis Prone Child in Rochester, NY

    Science.gov (United States)

    Pichichero, Michael E.

    2016-01-01

    This review summarizes a prospective, longitudinal 10-year study in Rochester NY with virtually every clinically diagnosed acute otitis media (AOM) confirmed by bacterial culture of middle ear fluid. Children experiencing 3 episodes within 6 months or 4 episodes in 12 months were considered stringently-defined otitis prone (sOP). We found stringent diagnosis compared with clinical diagnosis reduced the frequency of children meeting the OP definition from 27% to 6% resulting in 14.8% and 2.4% receiving tympanostomy tubes, respectively. Significantly more often RSV infection led to AOM in sOP than non-otitis prone (NOP) children that correlated with diminished total RSV-specific serum IgG. sOP children produced low levels of antibody to Streptococcus pneumoniae and Haemophilus influenzae candidate vaccine protein antigens and to routine pediatric vaccines. sOP children generated significantly fewer memory B cells, functional and memory T cells to otopathogens following NP colonization and AOM than NOP children and they had defects in antigen presenting cells. PMID:27273691

  2. Stringent homology-based prediction of H. sapiens-M. tuberculosis H37Rv protein-protein interactions.

    Science.gov (United States)

    Zhou, Hufeng; Gao, Shangzhi; Nguyen, Nam Ninh; Fan, Mengyuan; Jin, Jingjing; Liu, Bing; Zhao, Liang; Xiong, Geng; Tan, Min; Li, Shijun; Wong, Limsoon

    2014-04-08

    H. sapiens-M. tuberculosis H37Rv protein-protein interaction (PPI) data are essential for understanding the infection mechanism of the formidable pathogen M. tuberculosis H37Rv. Computational prediction is an important strategy to fill the gap in experimental H. sapiens-M. tuberculosis H37Rv PPI data. Homology-based prediction is frequently used in predicting both intra-species and inter-species PPIs. However, some limitations are not properly resolved in several published works that predict eukaryote-prokaryote inter-species PPIs using intra-species template PPIs. We develop a stringent homology-based prediction approach by taking into account (i) differences between eukaryotic and prokaryotic proteins and (ii) differences between inter-species and intra-species PPI interfaces. We compare our stringent homology-based approach to a conventional homology-based approach for predicting host-pathogen PPIs, based on cellular compartment distribution analysis, disease gene list enrichment analysis, pathway enrichment analysis and functional category enrichment analysis. These analyses support the validity of our prediction result, and clearly show that our approach has better performance in predicting H. sapiens-M. tuberculosis H37Rv PPIs. Using our stringent homology-based approach, we have predicted a set of highly plausible H. sapiens-M. tuberculosis H37Rv PPIs which might be useful for many of related studies. Based on our analysis of the H. sapiens-M. tuberculosis H37Rv PPI network predicted by our stringent homology-based approach, we have discovered several interesting properties which are reported here for the first time. We find that both host proteins and pathogen proteins involved in the host-pathogen PPIs tend to be hubs in their own intra-species PPI network. Also, both host and pathogen proteins involved in host-pathogen PPIs tend to have longer primary sequence, tend to have more domains, tend to be more hydrophilic, etc. And the protein domains from both

  3. The Stringent Response Induced by Phosphate Limitation Promotes Purine Salvage in Agrobacterium fabrum.

    Science.gov (United States)

    Sivapragasam, Smitha; Deochand, Dinesh K; Meariman, Jacob K; Grove, Anne

    2017-10-31

    Agrobacterium fabrum induces tumor growth in susceptible plant species. The upregulation of virulence genes that occurs when the bacterium senses plant-derived compounds is enhanced by acidic pH and limiting inorganic phosphate. Nutrient starvation may also trigger the stringent response, and purine salvage is among the pathways expected to be favored under such conditions. We show here that phosphate limitation induces the stringent response, as evidenced by production of (p)ppGpp, and that the xdhCSML operon encoding the purine salvage enzyme xanthine dehydrogenase is upregulated ∼15-fold. The xdhCSML operon is under control of the TetR family transcription factor XdhR; direct binding of ppGpp to XdhR attenuates DNA binding, and the enhanced xdhCSML expression correlates with increased cellular levels of (p)ppGpp. Xanthine dehydrogenase may also divert purines away from salvage pathways to form urate, the ligand for the transcription factor PecS, which in the plant pathogen Dickeya dadantii is a key regulator of virulence gene expression. However, urate levels remain low under conditions that produce increased levels of xdhCSML expression, and neither acidic pH nor limiting phosphate results in induction of genes under control of PecS. Instead, expression of such genes is induced only by externally supplemented urate. Taken together, our data indicate that purine salvage is favored during the stringent response induced by phosphate starvation, suggesting that control of this pathway may constitute a novel approach to modulating virulence. Because bacterial purine catabolism appears to be unaffected, as evidenced by the absence of urate accumulation, we further propose that the PecS regulon is induced by only host-derived urate.

  4. Diagnostic accuracy of modified kenneth jones scoring criteria (mkjsc) in confirmed cases of tuberculosis in children

    International Nuclear Information System (INIS)

    Farid, A.; Iqbal, S.M.J.; Hanif, A.

    2013-01-01

    Background: Tuberculosis (TB) is a granulomatous disease caused by Mycobacterium tuberculosis. The gold standard for the diagnosis of tuberculosis is detection of Mycobacterium tubercle bacilli. However, clinical scoring systems are most widely used for the diagnosis of TB in children. Objective: To determine the diagnostic accuracy of modified Kenneth Jones scoring criteria (MKJSC) in conformed cases of tuberculosis. Methodology: This cross-sectional comparative study was conducted in the department of Paediatrics, King Edward Medical University / Mayo Hospital, Lahore from January to June 2007. One hundred children below 15 years of age were enrolled. They were diagnosed as suspected cases of TB on the basis of fever and cough for more than 15 days. MKJSC was applied and each child was subjected to confirmatory test for TB. Results: There was an overall male preponderance of 54%. The mean age of study population was 1.8 +- 0.7 years. Out of 100 children, 66% were diagnosed as TB cases (23 with confirmatory tests and 43 with MKJSC of 5 or more). Sensitivity, specificity, positive and negative predictive value of MKJSC was 73.91%, 44.16%, 28.33%, and 85% respectively. Diagnostic accuracy of MKJSC was 51%. Conclusion: Present study does not support the hypothesis that MKJSC is a good alternative to confirmatory tests to diagnose tuberculosis in children. However, MKJSC is a simple tool, which can be applied to improve the case detection rate in the absence of sophisticated tests. (author)

  5. Stringent or nonstringent complete remission and prognosis in acute myeloid leukemia

    DEFF Research Database (Denmark)

    Øvlisen, Andreas K; Oest, Anders; Bendtsen, Mette D

    2018-01-01

    Stringent complete remission (sCR) of acute myeloid leukemia is defined as normal hematopoiesis after therapy. Less sCR, including non-sCR, was introduced as insufficient blood platelet, neutrophil, or erythrocyte recovery. These latter characteristics were defined retrospectively as postremission...... transfusion dependency and were suggested to be of prognostic value. In the present report, we evaluated the prognostic impact of achieving sCR and non-sCR in the Danish National Acute Leukaemia Registry, including 769 patients registered with classical CR (ie,

  6. International consensus diagnostic criteria for neuromyelitis optica spectrum disorders

    Science.gov (United States)

    Banwell, Brenda; Bennett, Jeffrey L.; Cabre, Philippe; Carroll, William; Chitnis, Tanuja; de Seze, Jérôme; Fujihara, Kazuo; Greenberg, Benjamin; Jacob, Anu; Jarius, Sven; Lana-Peixoto, Marco; Levy, Michael; Simon, Jack H.; Tenembaum, Silvia; Traboulsee, Anthony L.; Waters, Patrick; Wellik, Kay E.

    2015-01-01

    Neuromyelitis optica (NMO) is an inflammatory CNS syndrome distinct from multiple sclerosis (MS) that is associated with serum aquaporin-4 immunoglobulin G antibodies (AQP4-IgG). Prior NMO diagnostic criteria required optic nerve and spinal cord involvement but more restricted or more extensive CNS involvement may occur. The International Panel for NMO Diagnosis (IPND) was convened to develop revised diagnostic criteria using systematic literature reviews and electronic surveys to facilitate consensus. The new nomenclature defines the unifying term NMO spectrum disorders (NMOSD), which is stratified further by serologic testing (NMOSD with or without AQP4-IgG). The core clinical characteristics required for patients with NMOSD with AQP4-IgG include clinical syndromes or MRI findings related to optic nerve, spinal cord, area postrema, other brainstem, diencephalic, or cerebral presentations. More stringent clinical criteria, with additional neuroimaging findings, are required for diagnosis of NMOSD without AQP4-IgG or when serologic testing is unavailable. The IPND also proposed validation strategies and achieved consensus on pediatric NMOSD diagnosis and the concepts of monophasic NMOSD and opticospinal MS. PMID:26092914

  7. An accuracy measurement method for star trackers based on direct astronomic observation.

    Science.gov (United States)

    Sun, Ting; Xing, Fei; Wang, Xiaochu; You, Zheng; Chu, Daping

    2016-03-07

    Star tracker is one of the most promising optical attitude measurement devices and it is widely used in spacecraft for its high accuracy. However, how to realize and verify such an accuracy remains a crucial but unsolved issue until now. The authenticity of the accuracy measurement method of a star tracker will eventually determine the satellite performance. A new and robust accuracy measurement method for a star tracker based on the direct astronomical observation is proposed here. In comparison with the conventional method with simulated stars, this method utilizes real navigation stars as observation targets which makes the measurement results more authoritative and authentic. Transformations between different coordinate systems are conducted on the account of the precision movements of the Earth, and the error curves of directional vectors are obtained along the three axes. Based on error analysis and accuracy definitions, a three-axis accuracy evaluation criterion has been proposed in this paper, which could determine pointing and rolling accuracy of a star tracker directly. Experimental measurements confirm that this method is effective and convenient to implement. Such a measurement environment is close to the in-orbit conditions and it can satisfy the stringent requirement for high-accuracy star trackers.

  8. Diagnostic criteria for headache attributed to temporomandibular disorders.

    Science.gov (United States)

    Schiffman, Eric; Ohrbach, Richard; List, Thomas; Anderson, Gary; Jensen, Rigmor; John, Mike T; Nixdorf, Donald; Goulet, Jean-Paul; Kang, Wenjun; Truelove, Ed; Clavel, Al; Fricton, James; Look, John

    2012-07-01

    We assessed and compared the diagnostic accuracy of two sets of diagnostic criteria for headache secondary to temporomandibular disorders (TMD). In 373 headache subjects with TMD, a TMD headache reference standard was defined as: self-reported temple headache, consensus diagnosis of painful TMD and replication of the temple headache using TMD-based provocation tests. Revised diagnostic criteria for Headache attributed to TMD were selected using the RPART (recursive partitioning and regression trees) procedure, and refined in half of the data set. Using the remaining half of the data, the diagnostic accuracy of the revised criteria was compared to that of the International Headache Society's International Classification of Headache Diseases (ICHD)-II criteria A to C for Headache or facial pain attributed to temporomandibular joint (TMJ) disorder. Relative to the TMD headache reference standard, ICHD-II criteria showed sensitivity of 84% and specificity of 33%. The revised criteria for Headache attributed to TMD had sensitivity of 89% with improved specificity of 87% (p headache that is changed with jaw movement, function or parafunction and (2) provocation of that headache by temporalis muscle palpation or jaw movement. Having significantly better specificity than the ICHD-II criteria A to C, the revised criteria are recommended to diagnose headache secondary to TMD.

  9. Flight Hardware Packaging Design for Stringent EMC Radiated Emission Requirements

    Science.gov (United States)

    Lortz, Charlene L.; Huang, Chi-Chien N.; Ravich, Joshua A.; Steiner, Carl N.

    2013-01-01

    This packaging design approach can help heritage hardware meet a flight project's stringent EMC radiated emissions requirement. The approach requires only minor modifications to a hardware's chassis and mainly concentrates on its connector interfaces. The solution is to raise the surface area where the connector is mounted by a few millimeters using a pedestal, and then wrapping with conductive tape from the cable backshell down to the surface-mounted connector. This design approach has been applied to JPL flight project subsystems. The EMC radiated emissions requirements for flight projects can vary from benign to mission critical. If the project's EMC requirements are stringent, the best approach to meet EMC requirements would be to design an EMC control program for the project early on and implement EMC design techniques starting with the circuit board layout. This is the ideal scenario for hardware that is built from scratch. Implementation of EMC radiated emissions mitigation techniques can mature as the design progresses, with minimal impact to the design cycle. The real challenge exists for hardware that is planned to be flown following a built-to-print approach, in which heritage hardware from a past project with a different set of requirements is expected to perform satisfactorily for a new project. With acceptance of heritage, the design would already be established (circuit board layout and components have already been pre-determined), and hence any radiated emissions mitigation techniques would only be applicable at the packaging level. The key is to take a heritage design with its known radiated emissions spectrum and repackage, or modify its chassis design so that it would have a better chance of meeting the new project s radiated emissions requirements.

  10. Diagnosing autoimmune pancreatitis with the Unifying-Autoimmune-Pancreatitis-Criteria.

    Science.gov (United States)

    Schneider, Alexander; Michaely, Henrik; Rückert, Felix; Weiss, Christel; Ströbel, Philipp; Belle, Sebastian; Hirth, Michael; Wilhelm, Torsten J; Haas, Stephan L; Jesenofsky, Ralf; Schönberg, Stefan; Marx, Alexander; Singer, Manfred V; Ebert, Matthias P; Pfützer, Roland H; Löhr, J Matthias

    We had developed the Unifying-Autoimmune-Pancreatitis-Criteria (U-AIP) to diagnose autoimmune pancreatitis (AiP) within the M-ANNHEIM classification of chronic pancreatitis. In 2011, International-Consensus-Diagnostic-Criteria (ICDC) to diagnose AiP have been published. We had applied the U-AIP long before the ICDC were available. The aims of the study were, first, to describe patients with AiP diagnosed by the U-AIP; second, to compare diagnostic accuracies of the U-AIP and other diagnostic systems; third, to evaluate the clinical applicability of the U-AIP. From 1998 until 2008, we identified patients with AiP using U-AIP, Japanese-, Korean-, Asian-, Mayo-HISORt-, Revised-Mayo-HISORt- and Italian-criteria. We retrospectively verified the diagnosis by ICDC and Revised-Japanese-2011-criteria, compared diagnostic accuracies of all systems and evaluated all criteria in consecutive patients with pancreatitis (2009 until 2010, Pancreas-Outpatient-Clinic-Cohort, n = 84). We retrospectively validated our diagnostic approach in consecutive patients with a pancreatic lesion requiring surgery (Surgical-Cohort, n = 98). Overall, we identified 21 patients with AiP. Unifying-Autoimmune-Pancreatitis-Criteria and ICDC presented the highest diagnostic accuracies (each 98.8%), highest Youden indices (each 0.95238), and highest proportions of diagnosed patients (each n = 20/21, U-AIP/ICDC vs. other diagnostic systems, p Pancreatitis-Criteria revealed a satisfactory clinical applicability and offered an additional approach to diagnose AiP. Copyright © 2017 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  11. Thoracic injury rule out criteria and NEXUS chest in predicting the risk of traumatic intra-thoracic injuries: A diagnostic accuracy study.

    Science.gov (United States)

    Safari, Saeed; Radfar, Fatemeh; Baratloo, Alireza

    2018-05-01

    This study aimed to compare the diagnostic accuracy of NEXUS chest and Thoracic Injury Rule out criteria (TIRC) models in predicting the risk of intra-thoracic injuries following blunt multiple trauma. In this diagnostic accuracy study, using the 2 mentioned models, blunt multiple trauma patients over the age of 15 years presenting to emergency department were screened regarding the presence of intra-thoracic injuries that are detectable via chest x-ray and screening performance characteristics of the models were compared. In this study, 3118 patients with the mean (SD) age of 37.4 (16.9) years were studied (57.4% male). Based on TIRC and NEXUS chest, respectively, 1340 (43%) and 1417 (45.4%) patients were deemed in need of radiography performance. Sensitivity, specificity, and positive and negative predictive values of TIRC were 98.95%, 62.70%, 21.19% and 99.83%. These values were 98.61%, 59.94%, 19.97% and 99.76%, for NEXUS chest, respectively. Accuracy of TIRC and NEXUS chest models were 66.04 (95% CI: 64.34-67.70) and 63.50 (95% CI: 61.78-65.19), respectively. TIRC and NEXUS chest models have proper and similar sensitivity in prediction of blunt traumatic intra-thoracic injuries that are detectable via chest x-ray. However, TIRC had a significantly higher specificity in this regard. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Functional design criteria for project W-252, phase II liquid effluent treatment and disposal. Revision 2

    International Nuclear Information System (INIS)

    Hatch, C.E.

    1995-05-01

    This document is the Functional Design Criteria for Project W-252. Project W-252 provides the scope to provide BAT/AKART (best available technology...) to 200 Liquid Effluent Phase II streams (B-Plant). This revision (Rev. 2) incorporates a major descoping of the project. The descoping was done to reflect a combination of budget cutting measures allowed by a less stringent regulatory posture toward the Phase II streams

  13. Effectiveness of cleanup criteria relative to an accidental nuclear release

    International Nuclear Information System (INIS)

    Chen, S.Y.; Yuan, Y.C.

    1988-01-01

    In the event of an accidental nuclear release, the associated long-term radiological risks would result primarily from ground contamination pathways. Cleanup of the contaminated ground surfaces is a necessary step toward reducing the radiological risk to the general population. Ideally, the radiological risk decreases as the level of cleanup effort increases; however, as the cleanup criterion (i.e., the required contaminant concentration after cleanup) becomes more stringent, the cleanup effort may become prohibitively costly. This study examines several factors that are important in determining the effectiveness of the cleanup criteria for selected radionuclides: (a) annual individual dose commitment (mrem/yr), (b) total population environmental dose commitment (person-rem), and (c) total area (km 2 ) requiring cleanup following an accident. To effectively protect the general population, the benefits of cleanup should be weighed against the potentially large increase in cleanup area (and the associated costs) as the cleanup criterion becomes more stringent. The effectiveness of cleanup will vary, depending largely on site-specific parameters such as population density and agricultural productivity as well as on the amount and type of radionuclide released. Determination of an optimum cleanup criterion should account for all factors, including a comprehensive cost/benefit analysis

  14. Accuracy of radiologic and endoscopic diagnosis of gastric ulcer

    International Nuclear Information System (INIS)

    Gjoerup, T.; Agner, E.; Bording Jensen, L.; Moerup Jensen, A.; Moellmann, K.M.; Copenhagen Univ., Herlev; Copenhagen Univ.

    1987-01-01

    Patients with upper abdominal pain are often examined with both double contrast study of the stomach and endoscopy. On the basis of the results of the two examinations four diagnostic criteria of an ulcer can be formed: 1) radiography reveals an ulcer, 2) endoscopy reveals an ulcer, 3) both radiography and endoscopy reveal an ulcer, and 4) radiography and/or endoscopy reveals an ulcer. In a prospective study the accuracy of each of the four diagnostic criteria was examined. Eighty-two randomly selected outpatients had a double contrast barium examination and an upper gastrointestinal endoscopy performed by staff personnel. The diagnosis of a specialist in upper gastrointestinal endoscopy was used as the standard. For the four diagnostic criteria the overall accuracy ranged from 0.80 to 0.88. The predictive value of a positive test result was around 0.70 and the predictive value of a negative test result ranged from 0.81 to 0.96. The specificity ranged from 0.87 to 0.95, and the sensitivity from 0.38 to 0.90. It is concluded that from a clinical point of view, the accuracy of the four diagnostic criteria does not differ to an extent that justifies recommendation of one diagnostic criterion of gastric ulcer rather than the other. (orig.)

  15. Assessment of the diagnostic accuracy of {sup 18}F-FDG PET/CT in prosthetic infective endocarditis and cardiac implantable electronic device infection: comparison of different interpretation criteria

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez-Ballve, Ana; Jesus Perez-Castejon, Maria; Carreras-Delgado, Jose L. [Clinico San Carlos University Hospital, San Carlos Health Research Institute (IdISSC), Complutense University of Madrid, Department of Nuclear Medicine, Madrid (Spain); Delgado-Bolton, Roberto C. [Clinico San Carlos University Hospital, San Carlos Health Research Institute (IdISSC), Complutense University of Madrid, Department of Nuclear Medicine, Madrid (Spain); San Pedro Hospital and Centre for Biomedical Research of La Rioja (CIBIR), University of La Rioja, Department of Diagnostic Imaging (Radiology) and Nuclear Medicine, La Rioja (Spain); Sanchez-Enrique, Cristina; Vilacosta, Isidre; Vivas, David; Olmos, Carmen [Clinico San Carlos University Hospital, Department of Cardiology, Madrid (Spain); Ferrer, Manuel E.F. [Clinico San Carlos University Hospital, Research Unit, Madrid (Spain)

    2016-12-15

    The diagnosis of prosthetic valve (PV) infective endocarditis (IE) and infection of cardiac implantable electronic devices (CIEDs) remains challenging. The aim of this study was to assess the usefulness of {sup 18}F-FDG PET/CT in these patients and analyse the interpretation criteria. We included 41 patients suspected of having IE by the Duke criteria who underwent {sup 18}F-FDG PET/CT. The criteria applied for classifying the findings as positive/negative for IE were: (a) visual analysis of only PET images with attenuation-correction (AC PET images); (b) visual analysis of both AC PET images and PET images without AC (NAC PET images); (c) qualitative analysis of NAC PET images; and (d) semiquantitative analysis of AC PET images. {sup 18}F-FDG PET/CT was considered positive for IE independently of the intensity and distribution of FDG uptake. The gold standard was the Duke pathological criteria (if tissue was available) or the decision of an endocarditis expert team after a minimum 4 months follow-up. We studied 62 areas with suspicion of IE, 28 areas (45 %) showing definite IE and 34 (55 %) showing possible IE. Visual analysis of only AC PET images showed poor diagnostic accuracy (sensitivity 20 %, specificity 57 %). Visual analysis of both AC PET and NAC PET images showed excellent sensitivity (100 %) and intermediate specificity (73 %), focal uptake being more frequently associated with IE. The accuracy of qualitative analysis of NAC PET images depended on the threshold: the maximum sensitivity, specificity and accuracy achieved were 88 %, 80 %, 84 %, respectively. In the semiquantitative analysis of AC PET images, SUVmax was higher in areas of confirmed IE than in those without IE (∇SUVmax 2.2, p < 0.001). When FDG uptake was twice that in the liver, IE was always confirmed, and SUVmax 5.5 was the optimal threshold for IE diagnosis using ROC curve analysis (area under the curve 0.71). The value of {sup 18}F-FDG PET/CT in the diagnosis of suspected IE of PVs

  16. Assessment of the diagnostic accuracy of "1"8F-FDG PET/CT in prosthetic infective endocarditis and cardiac implantable electronic device infection: comparison of different interpretation criteria

    International Nuclear Information System (INIS)

    Jimenez-Ballve, Ana; Jesus Perez-Castejon, Maria; Carreras-Delgado, Jose L.; Delgado-Bolton, Roberto C.; Sanchez-Enrique, Cristina; Vilacosta, Isidre; Vivas, David; Olmos, Carmen; Ferrer, Manuel E.F.

    2016-01-01

    The diagnosis of prosthetic valve (PV) infective endocarditis (IE) and infection of cardiac implantable electronic devices (CIEDs) remains challenging. The aim of this study was to assess the usefulness of "1"8F-FDG PET/CT in these patients and analyse the interpretation criteria. We included 41 patients suspected of having IE by the Duke criteria who underwent "1"8F-FDG PET/CT. The criteria applied for classifying the findings as positive/negative for IE were: (a) visual analysis of only PET images with attenuation-correction (AC PET images); (b) visual analysis of both AC PET images and PET images without AC (NAC PET images); (c) qualitative analysis of NAC PET images; and (d) semiquantitative analysis of AC PET images. "1"8F-FDG PET/CT was considered positive for IE independently of the intensity and distribution of FDG uptake. The gold standard was the Duke pathological criteria (if tissue was available) or the decision of an endocarditis expert team after a minimum 4 months follow-up. We studied 62 areas with suspicion of IE, 28 areas (45 %) showing definite IE and 34 (55 %) showing possible IE. Visual analysis of only AC PET images showed poor diagnostic accuracy (sensitivity 20 %, specificity 57 %). Visual analysis of both AC PET and NAC PET images showed excellent sensitivity (100 %) and intermediate specificity (73 %), focal uptake being more frequently associated with IE. The accuracy of qualitative analysis of NAC PET images depended on the threshold: the maximum sensitivity, specificity and accuracy achieved were 88 %, 80 %, 84 %, respectively. In the semiquantitative analysis of AC PET images, SUVmax was higher in areas of confirmed IE than in those without IE (∇SUVmax 2.2, p < 0.001). When FDG uptake was twice that in the liver, IE was always confirmed, and SUVmax 5.5 was the optimal threshold for IE diagnosis using ROC curve analysis (area under the curve 0.71). The value of "1"8F-FDG PET/CT in the diagnosis of suspected IE of PVs and CIEDs is

  17. Perspectives on the revised Ghent criteria for the diagnosis of Marfan syndrome

    Directory of Open Access Journals (Sweden)

    von Kodolitsch Y

    2015-06-01

    Full Text Available Yskert von Kodolitsch,1 Julie De Backer,2 Helke Schüler,1 Peter Bannas,3 Cyrus Behzadi,3 Alexander M Bernhardt,1 Mathias Hillebrand,1 Bettina Fuisting,4 Sara Sheikhzadeh,1 Meike Rybczynski,1 Tilo Kölbel,1 Klaus Püschel,5 Stefan Blankenberg,1 Peter N Robinson61Centre of Cardiology, University Hospital Eppendorf, Hamburg, Germany; 2Centre for Medical Genetics, University Hospital Ghent, Ghent, Belgium; 3Diagnostic and Interventional Radiology Department and Clinic, 4Department of Ophthalmology, 5Department of Legal Medicine, University Hospital Eppendorf, Hamburg, Germany; 6Institute of Medical Genetics and Human Genetics, Charité Universitätsmedizin, Berlin, Germany Abstract: Three international nosologies have been proposed for the diagnosis of Marfan syndrome (MFS: the Berlin nosology in 1988; the Ghent nosology in 1996 (Ghent-1; and the revised Ghent nosology in 2010 (Ghent-2. We reviewed the literature and discussed the challenges and concepts of diagnosing MFS in adults. Ghent-1 proposed more stringent clinical criteria, which led to the confirmation of MFS in only 32%–53% of patients formerly diagnosed with MFS according to the Berlin nosology. Conversely, both the Ghent-1 and Ghent-2 nosologies diagnosed MFS, and both yielded similar frequencies of MFS in persons with a causative FBN1 mutation (90% for Ghent-1 versus 92% for Ghent-2 and in persons not having a causative FBN1 mutation (15% versus 13%. Quality criteria for diagnostic methods include objectivity, reliability, and validity. However, the nosology-based diagnosis of MFS lacks a diagnostic reference standard and, hence, quality criteria such as sensitivity, specificity, or accuracy cannot be assessed. Medical utility of diagnosis implies congruency with the historical criteria of MFS, as well as with information about the etiology, pathogenesis, diagnostic triggers, prognostic triggers, and potential complications of MFS. In addition, social and psychological utilities of

  18. Accuracy and detection limits for bioassay measurements in radiation protection. Statistical considerations

    International Nuclear Information System (INIS)

    Brodsky, A.

    1986-04-01

    This report provides statistical concepts and formulas for defining minimum detectable amount (MDA), bias and precision of sample analytical measurements of radioactivity for radiobioassay purposes. The defined statistical quantities and accuracy criteria were developed for use in standard performance criteria for radiobioassay, but are also useful in intralaboratory quality assurance programs. This report also includes a literature review and analysis of accuracy needs and accuracy recommendations of national and international scientific organizations for radiation or radioactivity measurements used for radiation protection purposes. Computer programs are also included for calculating the probabilities of passing or failing multiple analytical tests for different acceptable ranges of bias and precision

  19. Augmenting the Genetic Toolbox for Sulfolobus islandicus with a Stringent Positive Selectable Marker for Agmatine Prototrophy

    Science.gov (United States)

    Cooper, Tara E.; Krause, David J.

    2013-01-01

    Sulfolobus species have become the model organisms for studying the unique biology of the crenarchaeal division of the archaeal domain. In particular, Sulfolobus islandicus provides a powerful opportunity to explore natural variation via experimental functional genomics. To support these efforts, we further expanded genetic tools for S. islandicus by developing a stringent positive selection for agmatine prototrophs in strains in which the argD gene, encoding arginine decarboxylase, has been deleted. Strains with deletions in argD were shown to be auxotrophic for agmatine even in nutrient-rich medium, but growth could be restored by either supplementation of exogenous agmatine or reintroduction of a functional copy of the argD gene from S. solfataricus P2 into the ΔargD host. Using this stringent selection, a robust targeted gene knockout system was established via an improved next generation of the MID (marker insertion and unmarked target gene deletion) method. Application of this novel system was validated by targeted knockout of the upsEF genes involved in UV-inducible cell aggregation formation. PMID:23835176

  20. Accuracy of diagnosis criteria in patients with suspected diagnosis of sporadic Creutzfeldt-Jakob disease and detection of 14-3-3 protein, France, 1992 to 2009.

    Science.gov (United States)

    Peckeu, Laurene; Delasnerie-Lauprètre, Nicole; Brandel, Jean-Philippe; Salomon, Dominique; Sazdovitch, Véronique; Laplanche, Jean-Louis; Duyckaerts, Charles; Seilhean, Danielle; Haïk, Stéphane; Hauw, Jean-Jacques

    2017-10-01

    Diagnostic criteria of Creutzfeldt-Jakob disease (CJD), a rare and fatal transmissible nervous system disease with public health implications, are determined by clinical data, electroencephalogram (EEG), detection of 14-3-3 protein in cerebrospinal fluid (CSF), brain magnetic resonance imaging and prion protein gene examination. The specificity of protein 14-3-3 has been questioned. We reviewed data from 1,572 autopsied patients collected over an 18-year period (1992-2009) and assessed whether and how 14-3-3 detection impacted the diagnosis of sporadic CJD in France, and whether this led to the misdiagnosis of treatable disorders. 14-3-3 detection was introduced into diagnostic criteria for CJD in 1998. Diagnostic accuracy decreased from 92% for the 1992-1997 period to 85% for the 1998-2009 period. This was associated with positive detections of 14-3-3 in cases with negative EEG and alternative diagnosis at autopsy. Potentially treatable diseases were found in 163 patients (10.5%). This study confirms the usefulness of the recent modification of diagnosis criteria by the addition of the results of CSF real-time quaking-induced conversion, a method based on prion seed-induced misfolding and aggregation of recombinant prion protein substrate that has proven to be a highly specific test for diagnosis of sporadic CJD.

  1. Air Quality and Health Benefits of China's Recent Stringent Environmental Policy

    Science.gov (United States)

    Zheng, Y.; Xue, T.; Zhang, Q.; Geng, G.; He, K.

    2016-12-01

    Aggressive emission control measures were taken by China's central and local governments after the promulgation of the "Air Pollution Prevention and Control Action Plan" in 2013. We evaluated the air quality and health benefits of this ever most stringent air pollution control policy during 2013-2015 by utilizing a two-stage data fusion model and newly-developed cause-specific integrated exposure-response functions (IER) developed for the Global Burden of Disease (GBD). The two-stage data fusion model predicts spatiotemporal continuous PM2.5 (particulate matter with aerodynamic diameter less than 2.5 µm) concentrations by integrating satellite-derived aerosol optical depth (AOD) measurements, PM2.5 concentrations from measurement and air quality model, and other ancillary information. During the years of analysis, PM2.5 concentration dropped significantly on national average and over heavily polluted regions as identified by Mann-Kendall analysis. The national PM2.5-attributable mortality decreased by 72.8 (95% CI: 59.4, 85.2) thousand (6%) from 1.23 (95% CI: 1.06, 1.39) million in 2013 to 1.15 (95% CI: 0.98, 1.31) million in 2015 due to considerable reduction (i.e. 18%) of population-weighted PM2.5 from 61.4 to 50.5 µg/m3. Meteorological variations between 2013 and 2015 were estimated to raise the PM2.5 levels by 0.24 µg/m3 and national mortality by 2.1 (95% CI: 1.6, 2.6) thousand through sensitivity tests, which implies the dominant role of anthropogenic impacts on PM2.5 abatement and attributable mortality reduction. Our study affirms the effectiveness of China's recent air quality policy, however, due to the possible supralinear shape of C-R functions, health benefits induced by air quality improvement in these years are limited. We therefore appeal for continuous implementation of current policies and further stringent measures from both air quality improvement and public health protection perspectives.

  2. Multi-criteria decision analysis of energy system transformation pathways: A case study for Switzerland

    International Nuclear Information System (INIS)

    Volkart, Kathrin; Weidmann, Nicolas; Bauer, Christian; Hirschberg, Stefan

    2017-01-01

    Two recent political decisions are expected to frame the development of the Swiss energy system in the coming decades: the nuclear phase-out and the greenhouse gas (GHG) emission reduction target. To accomplish both of them, low-carbon technologies based on renewable energy and Carbon Capture and Storage (CCS) are expected to gain importance. The objective of the present work is to support prospective Swiss energy policy-making by providing a detailed sustainability analysis of possible energy system transformation pathways. For this purpose, the results of the scenario quantification with an energy system model are coupled with multi-criteria sustainability analysis. Two climate protection and one reference scenario are addressed, and the trade-offs between the scenarios are analysed based on a set of 12 interdisciplinary indicators. Implementing a stringent climate policy in Switzerland is associated with co-benefits such as less fossil resource use, less fatalities in severe accidents in the energy sector, less societal conflicts and higher resource autonomy. The availability and implementation of CCS allows for achieving the GHG emission reduction target at lower costs, but at the expense of a more fossil fuel-based energy system. - Highlights: • Three energy system transformation pathways for Switzerland are analysed. • A set of policy-relevant sustainability indicators are quantified for each pathway. • Implementing a stringent climate policy in Switzerland is associated with co-benefits. • In the CCS scenario fossil fuel use increases, but the total system costs are lower. • Fossil-fuelled transport substantially contributes to most of the addressed criteria.

  3. Legal status and source of offenders' firearms in states with the least stringent criteria for gun ownership.

    Science.gov (United States)

    Vittes, Katherine A; Vernick, Jon S; Webster, Daniel W

    2013-02-01

    Gun possession by high-risk individuals presents a serious threat to public safety. U.S. federal law establishes minimum criteria for legal purchase and possession of firearms; many states have laws disqualifying additional categories for illegal possession. We used data from a national survey of state prison inmates to calculate: 1) the proportion of offenders, incarcerated for crimes committed with firearms in 13 states with the least restrictive firearm purchase and possession laws, who would have been prohibited if their states had stricter gun laws; and 2) the source of gun acquisition for offenders who were and were not legally permitted to purchase and possess firearms. Nearly three of ten gun offenders (73 of 253 or 28.9%) were legal gun possessors but would have been prohibited from purchasing or possessing firearms when committing their most recent offense if their states had stricter prohibitions. Offenders who were already prohibited under current law acquired their gun from a licensed dealer, where a background check is required, five times less often than offenders who were not prohibited (3.9% vs. 19.9%; χ(2)=13.31; p≤0.001). Nearly all (96.1%) offenders who were legally prohibited, acquired their gun from a supplier not required to conduct a background check. Stricter gun ownership laws would have made firearm possession illegal for many state prison inmates who used a gun to commit a crime. Requiring all gun sales to be subject to a background check would make it more difficult for these offenders to obtain guns.

  4. Sensitivity and specificity of proposed DSM-5 diagnostic criteria for autism spectrum disorder.

    Science.gov (United States)

    McPartland, James C; Reichow, Brian; Volkmar, Fred R

    2012-04-01

    This study evaluated the potential impact of proposed DSM-5 diagnostic criteria for autism spectrum disorder (ASD). The study focused on a sample of 933 participants evaluated during the DSM-IV field trial; 657 carried a clinical diagnosis of an ASD, and 276 were diagnosed with a non-autistic disorder. Sensitivity and specificity for proposed DSM-5 diagnostic criteria were evaluated using field trial symptom checklists as follows: individual field trial checklist items (e.g., nonverbal communication); checklist items grouped together as described by a single DSM-5 symptom (e.g., nonverbal and verbal communication); individual DSM-5 criterion (e.g., social-communicative impairment); and overall diagnostic criteria. When applying proposed DSM-5 diagnostic criteria for ASD, 60.6% (95% confidence interval: 57%-64%) of cases with a clinical diagnosis of an ASD met revised DSM-5 diagnostic criteria for ASD. Overall specificity was high, with 94.9% (95% confidence interval: 92%-97%) of individuals accurately excluded from the spectrum. Sensitivity varied by diagnostic subgroup (autistic disorder = 0.76; Asperger's disorder = 0.25; pervasive developmental disorder-not otherwise specified = 0.28) and cognitive ability (IQ criteria could substantially alter the composition of the autism spectrum. Revised criteria improve specificity but exclude a substantial portion of cognitively able individuals and those with ASDs other than autistic disorder. A more stringent diagnostic rubric holds significant public health ramifications regarding service eligibility and compatibility of historical and future research. Copyright © 2012 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.

  5. Induction of a stringent metabolic response in intracellular stages of Leishmania mexicana leads to increased dependence on mitochondrial metabolism.

    Directory of Open Access Journals (Sweden)

    Eleanor C Saunders

    2014-01-01

    Full Text Available Leishmania parasites alternate between extracellular promastigote stages in the insect vector and an obligate intracellular amastigote stage that proliferates within the phagolysosomal compartment of macrophages in the mammalian host. Most enzymes involved in Leishmania central carbon metabolism are constitutively expressed and stage-specific changes in energy metabolism remain poorly defined. Using (13C-stable isotope resolved metabolomics and (2H2O labelling, we show that amastigote differentiation is associated with reduction in growth rate and induction of a distinct stringent metabolic state. This state is characterized by a global decrease in the uptake and utilization of glucose and amino acids, a reduced secretion of organic acids and increased fatty acid β-oxidation. Isotopomer analysis showed that catabolism of hexose and fatty acids provide C4 dicarboxylic acids (succinate/malate and acetyl-CoA for the synthesis of glutamate via a compartmentalized mitochondrial tricarboxylic acid (TCA cycle. In vitro cultivated and intracellular amastigotes are acutely sensitive to inhibitors of mitochondrial aconitase and glutamine synthetase, indicating that these anabolic pathways are essential for intracellular growth and virulence. Lesion-derived amastigotes exhibit a similar metabolism to in vitro differentiated amastigotes, indicating that this stringent response is coupled to differentiation signals rather than exogenous nutrient levels. Induction of a stringent metabolic response may facilitate amastigote survival in a nutrient-poor intracellular niche and underlie the increased dependence of this stage on hexose and mitochondrial metabolism.

  6. Detection capabilities and accuracy requirements of concentrations of radioactive material in air for radiation protection purposes

    International Nuclear Information System (INIS)

    Brodsky, A.

    1987-01-01

    Recent developments in the formulation of detection capability and accuracy criteria for bioassay measurements will be interpreted and adapted to provide similar criteria for the measurement of air concentrations of radioactive material for radiation protection purposes. Considerations of accuracy will be related to the known variability of measurement processes, as well as the uncertainties in the calculated limits of intake that serve as the basis of regulatory and voluntary standards of practice. Formulations and criteria will be presented for minimum detection amounts (MDA) and precision and bias of measurements for radiation protection purposes. 17 references

  7. Entropy of space-time outcome in a movement speed-accuracy task.

    Science.gov (United States)

    Hsieh, Tsung-Yu; Pacheco, Matheus Maia; Newell, Karl M

    2015-12-01

    The experiment reported was set-up to investigate the space-time entropy of movement outcome as a function of a range of spatial (10, 20 and 30 cm) and temporal (250-2500 ms) criteria in a discrete aiming task. The variability and information entropy of the movement spatial and temporal errors considered separately increased and decreased on the respective dimension as a function of an increment of movement velocity. However, the joint space-time entropy was lowest when the relative contribution of spatial and temporal task criteria was comparable (i.e., mid-range of space-time constraints), and it increased with a greater trade-off between spatial or temporal task demands, revealing a U-shaped function across space-time task criteria. The traditional speed-accuracy functions of spatial error and temporal error considered independently mapped to this joint space-time U-shaped entropy function. The trade-off in movement tasks with joint space-time criteria is between spatial error and timing error, rather than movement speed and accuracy. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Accuracy and precision evaluation of seven self-monitoring blood glucose systems.

    Science.gov (United States)

    Kuo, Chih-Yi; Hsu, Cheng-Teng; Ho, Cheng-Shiao; Su, Ting-En; Wu, Ming-Hsun; Wang, Chau-Jong

    2011-05-01

    Self-monitoring blood glucose (SMBG) systems play a critical role in management of diabetes. SMBG systems should at least meet the minimal requirement of the World Health Organization's ISO 15197:2003. For tight glycemic control, a tighter accuracy requirement is needed. Seven SMBG systems were evaluated for accuracy and precision: Bionime Rightest(™) GM550 (Bionime Corp., Dali City, Taiwan), Accu-Chek(®) Performa (Roche Diagnostics, Indianapolis, IN), OneTouch(®) Ultra(®)2 (LifeScan Inc., Milpitas, CA), MediSense(®) Optium(™) Xceed (Abbott Diabetes Care Inc., Alameda, CA), Medisafe (TERUMO Corp., Tokyo, Japan), Fora(®) TD4227 (Taidac Technology Corp., Wugu Township, Taiwan), and Ascensia Contour(®) (Bayer HealthCare LLC, Mishawaka, IN). The 107 participants (44 men and 63 women) were between 23 and 91 years old. The analytical results of seven SMBG systems were compared with those of plasma analyzed with the hexokinase method (Olympus AU640, Olympus America Inc., Center Valley, PA). The imprecision of the seven blood glucose meters ranged from 1.1% to 4.7%. Three of the seven blood glucose meters (42.9%) fulfilled the minimum accuracy criteria of ISO 15197:2003. The mean absolute relative error value for each blood glucose meter was calculated and ranged from 6.5% to 12.0%. More than 40% of evaluated SMBG systems meet the minimal accuracy criteria requirement of ISO 15197:2003. However, considering tighter criteria for accuracy of ±15%, only the Bionime Rightest GM550 meets this requirement. Because SMBG systems play a critical role in management of diabetes, manufacturers have to strive to improve accuracy and precision and to ensure the good quality of blood glucose meters and test strips.

  9. Validation of revised Epstein's criteria for insignificant prostate cancer prediction in a Greek subpopulation.

    Science.gov (United States)

    Chondros, Κ; Karpathakis, Ν; Heretis, Ι; Mavromanolakis, Ε; Chondros, N; Sofras, F; Mamoulakis, C

    2015-01-01

    Different treatment options for patients with prostate cancer (PCa) are applicable after stratifying patients according to various classification criteria. The purpose of our study is to evaluate the revised Epstein's criteria for insignificant PCa prediction in a Greek subpopulation. During a 4-year-period, 172 Cretan patients were submitted to radical retropubic prostatectomy in our institution. 23 out of them met the revised Epstein's criteria for the presence of clinically insignificant PCa (clinical stage T1c, prostate specific antigen density < 0.15 ng/ml/g, absence of Gleason pattern 4-5, <3 positive biopsy cores, presence of <50% tumor per core) during pre-treatment evaluation and were retrospectively included in the study. Post-surgery outcomes were evaluated including pathological stage, surgical margins and Gleason score upgrade. Organ confined disease and insignificant PCa were predicted with a 74% and 31% accuracy, respectively. These figures are remarkably lower than those derived from similar studies worldwide. Due to the high variation in the revised Epstein's criteria prediction accuracy observed worldwide, the development and implementation of novel tools/nomograms with a greater predictive accuracy is still warranted. Hippokratia 2015, 19 (1): 30-33.

  10. An Integrated Reverse Engineering Approach for Accuracy Control of Free-Form Objects

    Directory of Open Access Journals (Sweden)

    Pathak Vimal Kumar

    2016-12-01

    Full Text Available Computer-aided tools help in shortening and eradicating numerous repetitive tasks that reduces the gap between digital model and actual product. Use of these tools assists in realizing free-form objects such as custom fit products as described by a stringent interaction with the human body. Development of such a model presents a challenging situation for reverse engineering (RE which is not analogous with the requirement for generating simple geometric models. Hence, an alternating way of producing more accurate three-dimensional models is proposed. For creating accurate 3D models, point clouds are processed through filtering, segmentation, mesh smoothing and surface generation. These processes help in converting the initial unorganized point data into a 3D digital model and simultaneously influence the quality of model. This study provides an optimum balance for the best accuracy obtainable with maximum allowable deviation to lessen computer handling and processing time. A realistic non trivial case study of free-form prosthetic socket is considered. The accuracy obtained for the developed model is acceptable for the use in medical applications and FEM analysis.

  11. Dual Regulation of Bacillus subtilis kinB Gene Encoding a Sporulation Trigger by SinR through Transcription Repression and Positive Stringent Transcription Control.

    Science.gov (United States)

    Fujita, Yasutaro; Ogura, Mitsuo; Nii, Satomi; Hirooka, Kazutake

    2017-01-01

    It is known that transcription of kinB encoding a trigger for Bacillus subtilis sporulation is under repression by SinR, a master repressor of biofilm formation, and under positive stringent transcription control depending on the adenine species at the transcription initiation nucleotide (nt). Deletion and base substitution analyses of the kinB promoter (P kinB ) region using lacZ fusions indicated that either a 5-nt deletion (Δ5, nt -61/-57, +1 is the transcription initiation nt) or the substitution of G at nt -45 with A (G-45A) relieved kinB repression. Thus, we found a pair of SinR-binding consensus sequences (GTTCTYT; Y is T or C) in an inverted orientation (SinR-1) between nt -57/-42, which is most likely a SinR-binding site for kinB repression. This relief from SinR repression likely requires SinI, an antagonist of SinR. Surprisingly, we found that SinR is essential for positive stringent transcription control of P kinB . Electrophoretic mobility shift assay (EMSA) analysis indicated that SinR bound not only to SinR-1 but also to SinR-2 (nt -29/-8) consisting of another pair of SinR consensus sequences in a tandem repeat arrangement; the two sequences partially overlap the '-35' and '-10' regions of P kinB . Introduction of base substitutions (T-27C C-26T) in the upstream consensus sequence of SinR-2 affected positive stringent transcription control of P kinB , suggesting that SinR binding to SinR-2 likely causes this positive control. EMSA also implied that RNA polymerase and SinR are possibly bound together to SinR-2 to form a transcription initiation complex for kinB transcription. Thus, it was suggested in this work that derepression of kinB from SinR repression by SinI induced by Spo0A∼P and occurrence of SinR-dependent positive stringent transcription control of kinB might induce effective sporulation cooperatively, implying an intimate interplay by stringent response, sporulation, and biofilm formation.

  12. Systematic Review of the Diagnostic Accuracy and Therapeutic Effectiveness of Sacroiliac Joint Interventions.

    Science.gov (United States)

    Simopoulos, Thomas T; Manchikanti, Laxmaiah; Gupta, Sanjeeva; Aydin, Steve M; Kim, Chong Hwan; Solanki, Daneshvari; Nampiaparampil, Devi E; Singh, Vijay; Staats, Peter S; Hirsch, Joshua A

    2015-01-01

    The sacroiliac joint is well known as a cause of low back and lower extremity pain. Prevalence estimates are 10% to 25% in patients with persistent axial low back pain without disc herniation, discogenic pain, or radiculitis based on multiple diagnostic studies and systematic reviews. However, at present there are no definitive management options for treating sacroiliac joint pain. To evaluate the diagnostic accuracy and therapeutic effectiveness of sacroiliac joint interventions. A systematic review of the diagnostic accuracy and therapeutic effectiveness of sacroiliac joint interventions. The available literature on diagnostic and therapeutic sacroiliac joint interventions was reviewed. The quality assessment criteria utilized were the Quality Appraisal of Reliability Studies (QAREL) checklist for diagnostic accuracy studies, Cochrane review criteria to assess sources of risk of bias, and Interventional Pain Management Techniques-Quality Appraisal of Reliability and Risk of Bias Assessment (IPM-QRB) criteria for randomized therapeutic trials and Interventional Pain Management Techniques-Quality Appraisal of Reliability and Risk of Bias Assessment for Nonrandomized Studies (IPM-QRBNR) for observational therapeutic assessments. The level of evidence was based on a best evidence synthesis with modified grading of qualitative evidence from Level I to Level V. Data sources included relevant literature published from 1966 through March 2015 that were identified through searches of PubMed and EMBASE, manual searches of the bibliographies of known primary and review articles, and all other sources. For the diagnostic accuracy assessment, and for the therapeutic modalities, the primary outcome measure of pain relief and improvement in functional status were utilized. A total of 11 diagnostic accuracy studies and 14 therapeutic studies were included. The evidence for diagnostic accuracy is Level II for dual diagnostic blocks with at least 70% pain relief as the criterion

  13. Accuracy and Quality of Spirometry in Primary Care Offices.

    Science.gov (United States)

    Hegewald, Matthew J; Gallo, Heather M; Wilson, Emily L

    2016-12-01

    Spirometry is necessary for the optimal management of patients with respiratory disease. The quality of spirometry performed in the primary care setting has been inconsistent. We aimed to evaluate spirometer accuracy, determine the clinical significance of inaccurate spirometers, and assess the quality of spirograms obtained in primary care offices. We tested 17 spirometers used in primary care offices with a waveform generator; accuracy and precision were assessed using American Thoracic Society criteria. The clinical significance of inaccurate instruments was determined by applying the FEV 1 /FVC error from an obstructed waveform to a clinical data set. Spirogram quality was determined by grading spirograms using acceptability and repeatability criteria. The relationship between the number of tests performed by a clinic and test quality was assessed. Only 1 of 17 spirometers met accuracy criteria, with mean errors for FVC, FEV 1 , and FEV 1 /FVC ranging from 1.7 to 3.1%. Applying the percentage error to a clinical data set resulted in 28% of tests being recategorized from obstructed to nonobstructed. Of the spirograms reviewed, 60% were considered acceptable for clinical use. There was no association between the number of tests performed by a clinic and spirometry quality. Most spirometers tested were not accurate. The magnitude of the errors resulted in significant changes in the categorization of patients with obstruction. Acceptable-quality tests were produced for only 60% of patients. Our results raise concerns regarding the utility of spirometry obtained in primary care offices without greater attention to quality assurance and training.

  14. Evaluation of the 2010 McDonald multiple sclerosis criteria in children with a clinically isolated syndrome.

    Science.gov (United States)

    Kornek, Barbara; Schmitl, Beate; Vass, Karl; Zehetmayer, Sonja; Pritsch, Martin; Penzien, Johann; Karenfort, Michael; Blaschek, Astrid; Seidl, Rainer; Prayer, Daniela; Rostasy, Kevin

    2012-12-01

    Magnetic resonance imaging diagnostic criteria for paediatric multiple sclerosis have been established on the basis of brain imaging findings alone. The 2010 McDonald criteria for the diagnosis of multiple sclerosis, however, include spinal cord imaging for detection of lesion dissemination in space. The new criteria have been recommended in paediatric multiple sclerosis. (1) To evaluate the 2010 McDonald multiple sclerosis criteria in children with a clinically isolated syndrome and to compare them with recently proposed magnetic resonance criteria for children; (2) to assess whether the inclusion of spinal cord imaging provided additional value to the 2010 McDonald criteria. We performed a retrospective analysis of brain and spinal cord magnetic resonance imaging scans from 52 children with a clinically isolated syndrome. Sensitivity, specificity and accuracy of the magnetic resonance criteria were assessed. The 2010 McDonald dissemination in space criteria were more sensitive (85% versus 74%) but less specific (80% versus 100%) compared to the 2005 McDonald criteria. The Callen criteria were more accurate (89%) compared to the 2010 McDonald (85%), the 2005 McDonald criteria for dissemination in space (81%), the KIDMUS criteria (46%) and the Canadian Pediatric Demyelinating Disease Network criteria (76%). The 2010 McDonald criteria for dissemination in time were more accurate (93%) than the dissemination in space criteria (85%). Inclusion of the spinal cord did not increase the accuracy of the McDonald criteria.

  15. Evaluation Criteria and Indicators of Quality for Internet Resources.

    Science.gov (United States)

    Wilkinson, Gene L.; And Others

    1997-01-01

    Most Web site rating systems overemphasize technological "bells and whistles." The University of Georgia's information quality criteria address site access and usability; resource identification and documentation; author identification; authority of author; information structure and design; relevance and scope, validity, and accuracy and…

  16. Stringent limits on the ionized mass loss from A and F dwarfs

    International Nuclear Information System (INIS)

    Brown, A.; Veale, A.; Judge, P.; Bookbinder, J.A.; Hubeny, I.

    1990-01-01

    Following the suggestion of Willson et al. (1987) that A- and F-type main-sequence stars might undergo significant mass loss due to pulsationally driven winds, upper limits to the ionized mass loss from A and F dwarfs have been obtained using VLA observations. These stringent upper limits show that the level of ionized mass loss would have at most only a small effect on stellar evolution. Radiative-equilibrium atmospheric and wind models for early A dwarfs indicate that it is highly likely that a wind flowing from such stars would be significantly ionized. In addition, late A and early F dwarfs exhibit chromospheric emission indicative of significant nonradiative heating. The present mass-loss limits are thus representative of the total mass-loss rates for these stars. It is concluded that A and F dwarfs are not losing sufficient mass to cause A dwarfs to evolve into G dwarfs. 24 refs

  17. Evaluating clinical accuracy of continuous glucose monitoring devices: other methods

    NARCIS (Netherlands)

    Wentholt, Iris M. E.; Hart, August A.; Hoekstra, Joost B. L.; DeVries, J. Hans

    2008-01-01

    With more and more continuous glucose monitoring devices entering the market, the importance of adequate accuracy assessment grows. This review discusses pros and cons of Regression Analysis and Correlation Coefficient, Relative Difference measures, Bland Altman plot, ISO criteria, combined curve

  18. THE ACCURACY AND BIAS EVALUATION OF THE USA UNEMPLOYMENT RATE FORECASTS. METHODS TO IMPROVE THE FORECASTS ACCURACY

    Directory of Open Access Journals (Sweden)

    MIHAELA BRATU (SIMIONESCU

    2012-12-01

    Full Text Available In this study some alternative forecasts for the unemployment rate of USA made by four institutions (International Monetary Fund (IMF, Organization for Economic Co-operation and Development (OECD, Congressional Budget Office (CBO and Blue Chips (BC are evaluated regarding the accuracy and the biasness. The most accurate predictions on the forecasting horizon 201-2011 were provided by IMF, followed by OECD, CBO and BC.. These results were gotten using U1 Theil’s statistic and a new method that has not been used before in literature in this context. The multi-criteria ranking was applied to make a hierarchy of the institutions regarding the accuracy and five important accuracy measures were taken into account at the same time: mean errors, mean squared error, root mean squared error, U1 and U2 statistics of Theil. The IMF, OECD and CBO predictions are unbiased. The combined forecasts of institutions’ predictions are a suitable strategy to improve the forecasts accuracy of IMF and OECD forecasts when all combination schemes are used, but INV one is the best. The filtered and smoothed original predictions based on Hodrick-Prescott filter, respectively Holt-Winters technique are a good strategy of improving only the BC expectations. The proposed strategies to improve the accuracy do not solve the problem of biasness. The assessment and improvement of forecasts accuracy have an important contribution in growing the quality of decisional process.

  19. Clinical evaluation of the FreeStyle Precision Pro system.

    Science.gov (United States)

    Brazg, Ronald; Hughes, Kristen; Martin, Pamela; Coard, Julie; Toffaletti, John; McDonnell, Elizabeth; Taylor, Elizabeth; Farrell, Lausanne; Patel, Mona; Ward, Jeanne; Chen, Ting; Alva, Shridhara; Ng, Ronald

    2013-06-05

    A new version of international standard (ISO 15197) and CLSI Guideline (POCT12) with more stringent accuracy criteria are near publication. We evaluated the glucose test performance of the FreeStyle Precision Pro system, a new blood glucose monitoring system (BGMS) designed to enhance accuracy for point-of-care testing (POCT). Precision, interference and system accuracy with 503 blood samples from capillary, venous and arterial sources were evaluated in a multicenter study. Study results were analyzed and presented in accordance with the specifications and recommendations of the final draft ISO 15197 and the new POCT12. The FreeStyle Precision Pro system demonstrated acceptable precision (CV FreeStyle Precision Pro system met the tighter accuracy requirements, providing a means for enhancing accuracy for point-of-care blood glucose monitoring. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Checking the predictive accuracy of basic symptoms against ultra high-risk criteria and testing of a multivariable prediction model: Evidence from a prospective three-year observational study of persons at clinical high-risk for psychosis.

    Science.gov (United States)

    Hengartner, M P; Heekeren, K; Dvorsky, D; Walitza, S; Rössler, W; Theodoridou, A

    2017-09-01

    The aim of this study was to critically examine the prognostic validity of various clinical high-risk (CHR) criteria alone and in combination with additional clinical characteristics. A total of 188 CHR positive persons from the region of Zurich, Switzerland (mean age 20.5 years; 60.2% male), meeting ultra high-risk (UHR) and/or basic symptoms (BS) criteria, were followed over three years. The test battery included the Structured Interview for Prodromal Syndromes (SIPS), verbal IQ and many other screening tools. Conversion to psychosis was defined according to ICD-10 criteria for schizophrenia (F20) or brief psychotic disorder (F23). Altogether n=24 persons developed manifest psychosis within three years and according to Kaplan-Meier survival analysis, the projected conversion rate was 17.5%. The predictive accuracy of UHR was statistically significant but poor (area under the curve [AUC]=0.65, Pthinking of binary at-risk criteria is necessary in order to improve the prognosis of psychotic disorders. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. Diagnostic accuracy of temporomandibular disorder pain tests: a multicenter study

    NARCIS (Netherlands)

    Visscher, C.M.; Naeije, M.; de Laat, A.; Michelotti, A.; Nilner, M.; Craane, B.; Ekberg, E.; Farella, M.; Lobbezoo, F.

    2009-01-01

    AIMS: To estimate the diagnostic accuracy of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) clinical examination and of the dynamic/static tests for the recognition of TMD pain. Since the diagnosis of TMD pain is especially complicated in persistent orofacial pain

  2. Impact of different conditions on accuracy of five rules for principal components retention

    Directory of Open Access Journals (Sweden)

    Zorić Aleksandar

    2013-01-01

    Full Text Available Polemics about criteria for nontrivial principal components are still present in the literature. Finding of a lot of papers, is that the most frequently used Guttman Kaiser’s criterion has very poor performance. In the last three years some new criteria were proposed. In this Monte Carlo experiment we aimed to investigate the impact that sample size, number of analyzed variables, number of supposed factors and proportion of error variance have on the accuracy of analyzed criteria for principal components retention. We compared the following criteria: Bartlett’s χ2 test, Horn’s Parallel Analysis, Guttman-Kaiser’s eigenvalue over one, Velicer’s MAP and CHull originally proposed by Ceulemans & Kiers. Factors were systematically combined resulting in 690 different combinations. A total of 138,000 simulations were performed. Novelty in this research is systematic variation of the error variance. Performed simulations showed that, in favorable research conditions, all analyzed criteria work properly. Bartlett’s and Horns criterion expressed the robustness in most of analyzed situations. Velicer’s MAP had the best accuracy in situations with small number of subjects and high number of variables. Results confirm earlier findings of Guttman-Kaiser’s criterion having the worse performance.

  3. Clinical accuracy of ExacTrac intracranial frameless stereotactic system

    International Nuclear Information System (INIS)

    Ackerly, T.; Lancaster, C. M.; Geso, M.; Roxby, K. J.

    2011-01-01

    Purpose: In this paper, the authors assess the accuracy of the Brainlab ExacTrac system for frameless intracranial stereotactic treatments in clinical practice. Methods: They recorded couch angle and image fusion results (comprising lateral, longitudinal, and vertical shifts, and rotation corrections about these axes) for 109 stereotactic radiosurgery and 166 stereotactic radiotherapy patient treatments. Frameless stereotactic treatments involve iterative 6D image fusion corrections applied until the results conform to customizable pass criteria, theirs being 0.7 mm and 0.5 deg. for each axis. The planning CT slice thickness was 1.25 mm. It has been reported in the literature that the CT slices' thickness impacts the accuracy of localization to bony anatomy. The principle of invariance with respect to patient orientation was used to determine spatial accuracy. Results: The data for radiosurgery comprised 927 image pairs, of which 532 passed (pass ratio of 57.4%). The data for radiotherapy comprised 15983 image pairs, of which 10 050 passed (pass ratio of 62.9%). For stereotactic radiotherapy, the combined uncertainty of ExacTrac calibration, image fusion, and intrafraction motion was (95% confidence interval) 0.290-0.302 and 0.306-0.319 mm in the longitudinal and lateral axes, respectively. The combined uncertainty of image fusion and intrafraction motion in the anterior-posterior coordinates was 0.174-0.182 mm. For stereotactic radiosurgery, the equivalent ranges are 0.323-0.393, 0.337-0.409, and 0.231-0.281 mm. The overall spatial accuracy was 1.24 mm for stereotactic radiotherapy (SRT) and 1.35 mm for stereotactic radiosurgery (SRS). Conclusions: The ExacTrac intracranial frameless stereotactic system spatial accuracy is adequate for clinical practice, and with the same pass criteria, SRT is more accurate than SRS. They now use frameless stereotaxy exclusively at their center.

  4. Whole-Genome Microarray and Gene Deletion Studies Reveal Regulation of the Polyhydroxyalkanoate Production Cycle by the Stringent Response in Ralstonia eutropha H16

    Energy Technology Data Exchange (ETDEWEB)

    Brigham, CJ; Speth, DR; Rha, C; Sinskey, AJ

    2012-10-22

    Poly(3-hydroxybutyrate) (PHB) production and mobilization in Ralstonia eutropha are well studied, but in only a few instances has PHB production been explored in relation to other cellular processes. We examined the global gene expression of wild-type R. eutropha throughout the PHB cycle: growth on fructose, PHB production using fructose following ammonium depletion, and PHB utilization in the absence of exogenous carbon after ammonium was resupplied. Our results confirm or lend support to previously reported results regarding the expression of PHB-related genes and enzymes. Additionally, genes for many different cellular processes, such as DNA replication, cell division, and translation, are selectively repressed during PHB production. In contrast, the expression levels of genes under the control of the alternative sigma factor sigma(54) increase sharply during PHB production and are repressed again during PHB utilization. Global gene regulation during PHB production is strongly reminiscent of the gene expression pattern observed during the stringent response in other species. Furthermore, a ppGpp synthase deletion mutant did not show an accumulation of PHB, and the chemical induction of the stringent response with DL-norvaline caused an increased accumulation of PHB in the presence of ammonium. These results indicate that the stringent response is required for PHB accumulation in R. eutropha, helping to elucidate a thus-far-unknown physiological basis for this process.

  5. City-specific vehicle emission control strategies to achieve stringent emission reduction targets in China's Yangtze River Delta region.

    Science.gov (United States)

    Zhang, Shaojun; Wu, Ye; Zhao, Bin; Wu, Xiaomeng; Shu, Jiawei; Hao, Jiming

    2017-01-01

    The Yangtze River Delta (YRD) region is one of the most prosperous and densely populated regions in China and is facing tremendous pressure to mitigate vehicle emissions and improve air quality. Our assessment has revealed that mitigating vehicle emissions of NOx would be more difficult than reducing the emissions of other major vehicular pollutants (e.g., CO, HC and PM 2.5 ) in the YRD region. Even in Shanghai, where the emission control implemented are more stringent than in Jiangsu and Zhejiang, we observed little to no reduction in NOx emissions from 2000 to 2010. Emission-reduction targets for HC, NOx and PM 2.5 are determined using a response surface modeling tool for better air quality. We design city-specific emission control strategies for three vehicle-populated cities in the YRD region: Shanghai and Nanjing and Wuxi in Jiangsu. Our results indicate that even if stringent emission control consisting of the Euro 6/VI standards, the limitation of vehicle population and usage, and the scrappage of older vehicles is applied, Nanjing and Wuxi will not be able to meet the NOx emissions target by 2020. Therefore, additional control measures are proposed for Nanjing and Wuxi to further mitigate NOx emissions from heavy-duty diesel vehicles. Copyright © 2016. Published by Elsevier B.V.

  6. Achieving stringent climate targets. An analysis of the role of transport and variable renewable energies using energy-economy-climate models

    Energy Technology Data Exchange (ETDEWEB)

    Pietzcker, Robert Carl

    2014-07-01

    Anthropogenic climate change is threatening the welfare of mankind. Accordingly, policy makers have repeatedly stated the goal of slowing climate change and limiting the increase of global mean temperature to less than 2 C above pre-industrial times (the so-called ''two degree target''). Stabilizing the temperature requires drastic reductions of greenhouse gas (GHG) emissions to nearly zero. As the global system of energy supply currently relies on fossil fuels, reducing GHG emissions can only be achieved through a full-scale transformation of the energy system. This thesis investigates the economic requirements and implications of different scenarios that achieve stringent climate mitigation targets. It starts with the analysis of characteristic decarbonization patterns and identifies two particularly relevant aspects of mitigation scenarios: deployment of variable renewable energies (VRE) and decarbonization of the transport sector. After investigating these fields in detail, we turned towards one of the most relevant questions for policy makers and analyzed the trade-off between the stringency of a climate target and its economic requirements and implications. All analyses are based on the improvement, application, comparison, and discussion of large-scale IAMs. The novel ''mitigation share'' metric allowed us to identify the relevance of specific technology groups for mitigation and to improve our understanding of the decarbonization patterns of different energy subsectors. It turned out that the power sector is decarbonized first and reaches lowest emissions, while the transport sector is slowest to decarbonize. For the power sector, non-biomass renewable energies contribute most to emission reductions, while the transport sector strongly relies on liquid fuels and therefore requires biomass in combination with carbon capture and sequestration (CCS) to reduce emissions. An in-depth investigation of the solar power

  7. A New, Wireless-enabled Blood Glucose Monitoring System That Links to a Smart Mobile Device: Accuracy and User Performance Evaluation.

    Science.gov (United States)

    Christiansen, Mark; Greene, Carmine; Pardo, Scott; Warchal-Windham, Mary Ellen; Harrison, Bern; Morin, Robert; Bailey, Timothy S

    2017-05-01

    These studies investigated the accuracy of the new Contour ® Next ONE blood glucose monitoring system (BGMS) that is designed to sync with the Contour™ Diabetes app on a smartphone or tablet. A laboratory study tested fingertip capillary blood samples from 100 subjects in duplicate using 3 test strip lots, based on ISO 15197:2013 Section 6.3 analytical accuracy standards. A clinical study assessed accuracy per ISO 15197:2013 Section 8 criteria. Subjects with (n = 333) or without (n = 43) diabetes and who had not used the BGMS previously were enrolled. Each subject performed a self-test using the BGMS, which was repeated by a site staff member. Alternate site tests and venipunctures were also performed for analysis. A questionnaire was provided to assess user feedback on ease of use. In the laboratory study, 100% (600/600) of combined results for all 3 test strip lots met ISO 15197:2013 Section 6.3 accuracy criteria. In the clinical study, among subjects with diabetes, 99.4% (327/329) of subject self-test results, 99.7% (331/332) of results obtained by study staff, 97.2% (309/318) of subject palm results, and 100% (330/330) of venous results met ISO 15197:2013 Section 8 accuracy criteria. Moreover, 97.6% (321/329) of subject self-test results were within ±10 mg/dl (±0.6 mmol/L) or ±10% of the YSI reference result. Questionnaire results indicated that most subjects considered the system easy to use. The BGMS exceeded ISO 15197:2013 accuracy criteria in the laboratory and in a clinical setting.

  8. Multi-criteria Group Decision Making Approach for Teacher Recruitment in Higher Education under Simplified Neutrosophic Environment

    Directory of Open Access Journals (Sweden)

    Kalyan Mondal

    2014-12-01

    Full Text Available Teacher recruitment is a multi-criteria group decisionmaking process involving subjectivity, imprecision, and fuzziness that can be suitably represented by neutrosophic sets. Neutrosophic set, a generalization of fuzzy sets is characterized by a truth-membership function, falsity-membership function and an indeterminacy-membership function. These functions are real standard or non-standard subsets of ] 0-, 1+[ .There is no restriction on the sum of the functions, so the sum lies between ]0-, 3+[. A neutrosophic approach is a more general and suitable way to deal with imprecise information, when compared to a fuzzy set. The purpose of this study is to develop a neutrosophic multi-criteria group decision-making model based on hybrid scoreaccuracy functions for teacher recruitment in higher education. Eight criteria obtained from expert opinions are considered for recruitment process. The criteria are namely academic performance index, teaching aptitude, subject knowledge, research experience, leadership quality, personality, management capacity, and personal values. In this paper we use the score and accuracy functions and the hybrid score-accuracy functions of single valued neutrosophic numbers (SVNNs and ranking method for SVNNs. Then, multi-criteria group decision-making method with unknown weights for attributes and incompletely known weights for decision makers is used based on the hybrid score-accuracy functions under single valued neutrosophic environments. We use weight model for attributes based on the hybrid score-accuracy functions to derive the weights of decision makers and attributes from the decision matrices represented by the form of SVNNs to decrease the effect of some unreasonable evaluations. Moreover, we use the overall evaluation formulae of the weighted hybrid scoreaccuracy functions for each alternative to rank the alternatives and recruit the most desirable teachers. Finally, an educational problem for teacher selection is

  9. Response moderation models for conditional dependence between response time and response accuracy.

    Science.gov (United States)

    Bolsinova, Maria; Tijmstra, Jesper; Molenaar, Dylan

    2017-05-01

    It is becoming more feasible and common to register response times in the application of psychometric tests. Researchers thus have the opportunity to jointly model response accuracy and response time, which provides users with more relevant information. The most common choice is to use the hierarchical model (van der Linden, 2007, Psychometrika, 72, 287), which assumes conditional independence between response time and accuracy, given a person's speed and ability. However, this assumption may be violated in practice if, for example, persons vary their speed or differ in their response strategies, leading to conditional dependence between response time and accuracy and confounding measurement. We propose six nested hierarchical models for response time and accuracy that allow for conditional dependence, and discuss their relationship to existing models. Unlike existing approaches, the proposed hierarchical models allow for various forms of conditional dependence in the model and allow the effect of continuous residual response time on response accuracy to be item-specific, person-specific, or both. Estimation procedures for the models are proposed, as well as two information criteria that can be used for model selection. Parameter recovery and usefulness of the information criteria are investigated using simulation, indicating that the procedure works well and is likely to select the appropriate model. Two empirical applications are discussed to illustrate the different types of conditional dependence that may occur in practice and how these can be captured using the proposed hierarchical models. © 2016 The British Psychological Society.

  10. The DSM diagnostic criteria for gender identity disorder in adolescents and adults.

    Science.gov (United States)

    Cohen-Kettenis, Peggy T; Pfäfflin, Friedemann

    2010-04-01

    Apart from some general issues related to the Gender Identity Disorder (GID) diagnosis, such as whether it should stay in the DSM-V or not, a number of problems specifically relate to the current criteria of the GID diagnosis for adolescents and adults. These problems concern the confusion caused by similarities and differences of the terms transsexualism and GID, the inability of the current criteria to capture the whole spectrum of gender variance phenomena, the potential risk of unnecessary physically invasive examinations to rule out intersex conditions (disorders of sex development), the necessity of the D criterion (distress and impairment), and the fact that the diagnosis still applies to those who already had hormonal and surgical treatment. If the diagnosis should not be deleted from the DSM, most of the criticism could be addressed in the DSM-V if the diagnosis would be renamed, the criteria would be adjusted in wording, and made more stringent. However, this would imply that the diagnosis would still be dichotomous and similar to earlier DSM versions. Another option is to follow a more dimensional approach, allowing for different degrees of gender dysphoria depending on the number of indicators. Considering the strong resistance against sexuality related specifiers, and the relative difficulty assessing sexual orientation in individuals pursuing hormonal and surgical interventions to change physical sex characteristics, it should be investigated whether other potentially relevant specifiers (e.g., onset age) are more appropriate.

  11. Evaluation of Web-Based Training Courses by Means of Criteria on Learning Support

    Energy Technology Data Exchange (ETDEWEB)

    Geisser, R.; Keefer, F.; Schoenfelder, C.

    2015-07-01

    In recent years, due to the widespread use of digital media and the internet, more and more traditional education and training measures have been replaced or enhanced by elearning. In the context of the nuclear industry, however, with its stringent demand for well qualified and motivated human resources, it is very important to know to what extent these new learning formats will contribute to effective education and training. In cooperation with AREVA and within the scope of a master thesis, it was first investigated as to which factors greatly support the effectiveness of learning by using digital media, from a learner’s point of view in particular. Then, several criteria were developed that could be used to evaluate web based training courses. Next, these criteria were applied to three courses that have already been implemented at AREVA for different target groups and training objectives. The investigation has shown that factors which support the effectiveness of learning are not well known and not systematically applied in the training development process. Consequently, the success of training implementation depends to a great extent on the competence of external suppliers for e-learning programming. (Author)

  12. Acceptance criteria considerations for miscellaneous wastes

    International Nuclear Information System (INIS)

    Irvine, A.R.; Forsberg, C.W.

    1987-01-01

    EPA standards set forth limitations regarding releases to the accessible environment adjacent to a geologic repository. The NRC criteria pertaining to waste form and engineered barrier performance place certain restrictions on the physical and chemical nature of the waste form and require substantially complete confinement of radioactivity until the high-heat-production period is past. After this period, the annual release of radionuclides from the waste package is normally limited to 1 part in 100,000 of the amounts calculated to be present at 1000-y decay. The regulation permits deviation from these criteria in exceptional circumstances. One such circumstance might be the absence of a significant perturbation in temperature around the stored waste. The lack of significant heat release will eliminate the hydrologic driving force for dispersal of radionuclides. Exceptional circumstances which potentially could justify a less stringent long-term release criterion are: small quantity of radioactivity, the nature of the radioactive species, and the nature of the geology in which the waste is to be emplaced. Because the MW after a suitable decay period have low heat release rates per unit volume, they apparently could be so emplaced in a repository that there would be no compelling need, according to the reasoning presented in 10 CFR 60, for a 1000-y container. Regarding attainment of the specified long-term release rate criterion, neither the solubility limits for the various waste forms nor the conductance of potential migration barriers are currently adequately characterized. The relatively small total heat generation rate for the MW in combination with the usual low volumetric heat generation rate apparently will allow application of migration barriers in a low temperature environment where barrier performance would be expected to be unchanged with time

  13. Plutonium contamination at Maralinga - dosimetry and clean-up criteria

    International Nuclear Information System (INIS)

    Cooper, M.B.; Martin, L.J.; O'Brien, R.S.; Williams, G.A.

    1998-01-01

    An area of South Australia remained contaminated following British nuclear weapons tests at Maralinga during 1955 - 1963. Of importance is the long-lived 239-Pu of which some 24 kg was explosively dispersed in several 'minor trials'. The extent, quantities and physical characteristics of the plutonium have been assessed and estimates of dose, dominated by the inhalation pathway in the critical group of Aborigines living a semi-traditional lifestyle, have been made for potential occupants. Rehabilitation of the most contaminated areas is underway, involving scraping of surface soil and burial at depth on site. Dosimetry, together with social and economic factors, underpins the setting of clean-up criteria in terms of activity concentrations averaged over large areas and permissible concentrations of contaminated particles. The possibility of intentional behaviour such as fragment scavenging has also influenced limits on particulate contamination.The standard for this intervention is that the annual committed dose, for any scenario involving permanent occupancy by semi-traditional Aborigines, will be less than 5 mSv. In fact, following the clean-up, annual doses are not expected to exceed 1 mSv for all realistic scenarios. The possibility of intentional behaviour, such as fragment scavenging, has led to limits on particulate contamination. Three plutonium-contaminated sites have been treated by soil-removal. At Taranaki, the most contaminated site, by limiting the activity of the remaining soil to below about 400 kBq/m2 of 239Pu, and by limiting occupancy factors to those typical of hunting activities in a particular location (0.8%), the dose criteria will be met. An area of about 1.5 km 2 has been treated by removal of surface soil at Taranaki. At the other two sites, with no occupancy constraints, more stringent soil-removal criteria have been applied

  14. Derivative criteria of plasticity anddurability of metal materials

    Directory of Open Access Journals (Sweden)

    Gustov Yuriy Ivanovich

    Full Text Available Criteria of plasticity and durability derivative of standard indicators of plasticity (δ, ψ and durability (σ , σ are offered. Criteria К and К follow from the equation of relative indicators of durability and plasticity. The purpose of the researches is the establishment of interrelation of derivative criteria with the Page indicator. The values of derivative criteria were defined for steels 50X and 50XH after processing by cold, and also for steels 50G2 and 38HGN after sorbitizing. It was established that the sum of the offered derivative criteria of plasticity and durability С considered for the steels is almost equal to unit and corresponds to a square root of relative durability and plasticity criterion C . Both criteria testify to two-unity opposite processes of deformation and resistance to deformation. By means of the equations for S and С it is possible to calculate an indicator of uniform plastic deformation of σ and through it to estimate synergetic criteria - true tension and specific energy of deformation and destruction of metal materials. On the basis of the received results the expressions for assessing the uniform and concentrated components of plastic deformation are established. The preference of the dependence of uniform relative lengthening from a cubic root of criterion К , and also to work of the criteria of relative lengthening and relative durability is given. The advantage of the formulas consists in simplicity and efficiency of calculation, in ensuring necessary accuracy of calculation of the size δ for the subsequent calculation of structural and power (synergetic criteria of reliability of metals.

  15. Ribosome•RelA structures reveal the mechanism of stringent response activation

    Science.gov (United States)

    Loveland, Anna B; Bah, Eugene; Madireddy, Rohini; Zhang, Ying; Brilot, Axel F; Grigorieff, Nikolaus; Korostelev, Andrei A

    2016-01-01

    Stringent response is a conserved bacterial stress response underlying virulence and antibiotic resistance. RelA/SpoT-homolog proteins synthesize transcriptional modulators (p)ppGpp, allowing bacteria to adapt to stress. RelA is activated during amino-acid starvation, when cognate deacyl-tRNA binds to the ribosomal A (aminoacyl-tRNA) site. We report four cryo-EM structures of E. coli RelA bound to the 70S ribosome, in the absence and presence of deacyl-tRNA accommodating in the 30S A site. The boomerang-shaped RelA with a wingspan of more than 100 Å wraps around the A/R (30S A-site/RelA-bound) tRNA. The CCA end of the A/R tRNA pins the central TGS domain against the 30S subunit, presenting the (p)ppGpp-synthetase domain near the 30S spur. The ribosome and A/R tRNA are captured in three conformations, revealing hitherto elusive states of tRNA engagement with the ribosomal decoding center. Decoding-center rearrangements are coupled with the step-wise 30S-subunit 'closure', providing insights into the dynamics of high-fidelity tRNA decoding. DOI: http://dx.doi.org/10.7554/eLife.17029.001 PMID:27434674

  16. Classical fluoroscopy criteria poorly predict right ventricular lead septal positioning by comparison with echocardiography.

    Science.gov (United States)

    Squara, Fabien; Scarlatti, Didier; Riccini, Philippe; Garret, Gauthier; Moceri, Pamela; Ferrari, Emile

    2018-03-13

    Fluoroscopic criteria have been described for the documentation of septal right ventricular (RV) lead positioning, but their accuracy remains questioned. Consecutive patients undergoing pacemaker or defibrillator implantation were prospectively included. RV lead was positioned using postero-anterior and left anterior oblique 40° incidences, and right anterior oblique 30° to rule out coronary sinus positioning when suspected. RV lead positioning using fluoroscopy was compared to true RV lead positioning as assessed by transthoracic echocardiography (TTE). Precise anatomical localizations were determined with both modalities; then, RV lead positioning was ultimately dichotomized into two simple clinically relevant categories: RV septal or RV free wall. Accuracy of fluoroscopy for RV lead positioning was then assessed by comparison with TTE. We included 100 patients. On TTE, 66/100 had a septal RV lead and 34/100 had a free wall RV lead. Fluoroscopy had moderate agreement with TTE for precise anatomical localization of RV lead (k = 0.53), and poor agreement for septal/free wall localization (k = 0.36). For predicting septal RV lead positioning, classical fluoroscopy criteria had a high sensitivity (95.5%; 63/66 patients having a septal RV lead on TTE were correctly identified by fluoroscopy) but a very low specificity (35.3%; only 12/34 patients having a free wall RV lead on TTE were correctly identified by fluoroscopy). Classical fluoroscopy criteria have a poor accuracy for identifying RV free wall leads, which are most of the time misclassified as septal. This raises important concerns about the efficacy and safety of RV lead positioning using classical fluoroscopy criteria.

  17. MSCT multi-criteria: A novel approach in assessment of mediastinal lymph node metastases in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Volterrani, Luca; Mazzei, Maria Antonietta; Banchi, Benedetta; Voltolini, Luca; La Sala, Filomena; Carbone, Salvatore Francesco; Ricci, Veronica; Gotti, Giuseppe; Zompatori, Maurizio

    2011-01-01

    Summary: Purpose: To evaluate the accuracy of multi-slice computed tomography (MSCT) in diagnosing mediastinal lymph node metastases in patients with non-small cell lung cancer (NSCLC) using a multi-criteria approach. Methods: We retrospectively reviewed contrast-enhanced MSCT of the chest in 86 consecutive patients with histopathologically proven NSCLC. All patients underwent surgical lymph node resection within 30 days from the CT examination. In all cases pathological and CT results were reviewed and correlated. Results: The sensitivity, specificity, positive and negative predictive values, and accuracy of MSCT using a multi-criteria approach in the detection of the N2 stage were 100%, 98.5%, 100%, 94.4% and 98.8% respectively, whereas using the size criterion alone 64%, 61%, 87%, 40%, and 62% respectively. Conclusions: To improve MSCT accuracy for diagnosing N staging other criteria can be associated with lymph node size. The use of different dimensional cut-offs for each mediastinal lymph node station, the matching of positive nodal stations with tumour location, the structural characteristics and the type of enhancement allow for a high accuracy of MSCT in the staging of mediastinal nodes in NSCLC.

  18. Criteria for performance evaluation

    Directory of Open Access Journals (Sweden)

    David J. Weiss

    2009-03-01

    Full Text Available Using a cognitive task (mental calculation and a perceptual-motor task (stylized golf putting, we examined differential proficiency using the CWS index and several other quantitative measures of performance. The CWS index (Weiss and Shanteau, 2003 is a coherence criterion that looks only at internal properties of the data without incorporating an external standard. In Experiment 1, college students (n = 20 carried out 2- and 3-digit addition and multiplication problems under time pressure. In Experiment 2, experienced golfers (n = 12, also college students, putted toward a target from nine different locations. Within each experiment, we analyzed the same responses using different methods. For the arithmetic tasks, accuracy information (mean absolute deviation from the correct answer, MAD using a coherence criterion was available; for golf, accuracy information using a correspondence criterion (mean deviation from the target, also MAD was available. We ranked the performances of the participants according to each measure, then compared the orders using Spearman's rextsubscript{s}. For mental calculation, the CWS order correlated moderately (rextsubscript{s} =.46 with that of MAD. However, a different coherence criterion, degree of model fit, did not correlate with either CWS or accuracy. For putting, the ranking generated by CWS correlated .68 with that generated by MAD. Consensual answers were also available for both experiments, and the rankings they generated correlated highly with those of MAD. The coherence vs. correspondence distinction did not map well onto criteria for performance evaluation.

  19. Haptic perception accuracy depending on self-produced movement.

    Science.gov (United States)

    Park, Chulwook; Kim, Seonjin

    2014-01-01

    This study measured whether self-produced movement influences haptic perception ability (experiment 1) as well as the factors associated with levels of influence (experiment 2) in racket sports. For experiment 1, the haptic perception accuracy levels of five male table tennis experts and five male novices were examined under two different conditions (no movement vs. movement). For experiment 2, the haptic afferent subsystems of five male table tennis experts and five male novices were investigated in only the self-produced movement-coupled condition. Inferential statistics (ANOVA, t-test) and custom-made devices (shock & vibration sensor, Qualisys Track Manager) of the data were used to determine the haptic perception accuracy (experiment 1, experiment 2) and its association with expertise. The results of this research show that expert-level players acquire higher accuracy with less variability (racket vibration and angle) than novice-level players, especially in their self-produced movement coupled performances. The important finding from this result is that, in terms of accuracy, the skill-associated differences were enlarged during self-produced movement. To explain the origin of this difference between experts and novices, the functional variability of haptic afferent subsystems can serve as a reference. These two factors (self-produced accuracy and the variability of haptic features) as investigated in this study would be useful criteria for educators in racket sports and suggest a broader hypothesis for further research into the effects of the haptic accuracy related to variability.

  20. Regulatory analysis on criteria for the release of patients administered radioactive material

    International Nuclear Information System (INIS)

    Schneider, S.; McGuire, S.A.

    1994-05-01

    The Nuclear Regulatory Commission (NRC) has received two petitions to amend its regulations in 10 CFR Parts 20 and 35 as they apply to doses received by members of the public exposed to patients released from a hospital after they have been administered radioactive material. While the two petitions are not identical they both request that the NRC establish a dose limit of 5 millisieverts (0.5 rem) per year for individuals exposed to patients who have been administered radioactive materials. This Regulatory Analysis evaluates three alternatives. Alternative 1 is for the NRC to amend its patient release criteria in 10 CFR 35.75 to use the more stringent dose limit of 1 millisievert per year in 10 CFR 20.1301(a) for its patient release criteria. Alternative 2 is for the NRC to continue using the existing patient release criteria in 10 CFR 35.75 of 1,110 megabecquerels of activity or a dose rate at one meter from the patient of 0.05 millisievert per hour. Alternative 3 is for the NRC to amend the patient release criteria in 10 CFR 35.75 to specify a dose limit of 5 millisieverts for patient release. The evaluation indicates that Alternative 1 would cause a prohibitively large increase in the national health care cost from retaining patients in a hospital longer and would cause significant personal and psychological costs to patients and their families. The choice of Alternatives 2 or 3 would affect only thyroid cancer patients treated with iodine-131. For those patients, Alternative 3 would result in less hospitalization than Alternative 2. Alternative 3 has a potential decrease in national health care cost of $30,000,000 per year but would increase the potential collective dose from released therapy patients by about 2,700 person-rem per year, mainly to family members

  1. Regulatory analysis on criteria for the release of patients administered radioactive material

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, S.; McGuire, S.A. [Nuclear Regulatory Commission, Washington, DC (United States). Div. of Regulatory Applications; Behling, U.H.; Behling, K.; Goldin, D. [Cohen (S.) and Associates, Inc., McLean, VA (United States)

    1994-05-01

    The Nuclear Regulatory Commission (NRC) has received two petitions to amend its regulations in 10 CFR Parts 20 and 35 as they apply to doses received by members of the public exposed to patients released from a hospital after they have been administered radioactive material. While the two petitions are not identical they both request that the NRC establish a dose limit of 5 millisieverts (0.5 rem) per year for individuals exposed to patients who have been administered radioactive materials. This Regulatory Analysis evaluates three alternatives. Alternative 1 is for the NRC to amend its patient release criteria in 10 CFR 35.75 to use the more stringent dose limit of 1 millisievert per year in 10 CFR 20.1301(a) for its patient release criteria. Alternative 2 is for the NRC to continue using the existing patient release criteria in 10 CFR 35.75 of 1,110 megabecquerels of activity or a dose rate at one meter from the patient of 0.05 millisievert per hour. Alternative 3 is for the NRC to amend the patient release criteria in 10 CFR 35.75 to specify a dose limit of 5 millisieverts for patient release. The evaluation indicates that Alternative 1 would cause a prohibitively large increase in the national health care cost from retaining patients in a hospital longer and would cause significant personal and psychological costs to patients and their families. The choice of Alternatives 2 or 3 would affect only thyroid cancer patients treated with iodine-131. For those patients, Alternative 3 would result in less hospitalization than Alternative 2. Alternative 3 has a potential decrease in national health care cost of $30,000,000 per year but would increase the potential collective dose from released therapy patients by about 2,700 person-rem per year, mainly to family members.

  2. 40 CFR Appendix F to Part 132 - Great Lakes Water Quality Initiative Implementation Procedures

    Science.gov (United States)

    2010-07-01

    ...-specific modifications that result in less stringent criteria must be based on a sound scientific rationale... Handbook, Second Edition—Revised (1994). b. Less stringent site-specific modifications to chronic or acute...-specific criteria is provided in Chapter 3 of the U.S. EPA Water Quality Standards Handbook, Second Edition...

  3. Is there any evidence for the validity of diagnostic criteria used for accommodative and nonstrabismic binocular dysfunctions?

    Directory of Open Access Journals (Sweden)

    Pilar Cacho-Martínez

    2014-01-01

    Conclusions: Scientific literature reveals differences between authors according to diagnostic criteria for accommodative and nonstrabismic binocular dysfunctions. Diagnostic accuracy studies show that there is only certain evidence for accommodative conditions. For binocular anomalies there is only evidence about a validated questionnaire for convergence insufficiency with no data of diagnostic accuracy.

  4. Applicability of McDonald 2010 and Magnetic Resonance Imaging in Multiple Sclerosis (MAGNIMS) 2016 Magnetic Resonance Imaging Criteria for the Diagnosis of Multiple Sclerosis in Sri Lanka.

    Science.gov (United States)

    Gamage, Sujani Madhurika Kodagoda; Wijeweera, Indunil; Wijesinghe, Priyangi; Adikari, Sanjaya Bandara; Fink, Katharina; Sominanda, Herath Mudiyanselage Ajith

    2018-05-31

    The magnetic resonance imaging in multiple sclerosis (MAGNIMS) group recently proposed guidelines to replace the existing dissemination-in-space criteria in McDonald 2010 magnetic resonance imaging (MRI) criteria for diagnosing multiple sclerosis. There has been insufficient research regarding their applicability in Asians. Objective of this study was to determine the sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of McDonald 2010 and MAGNIMS 2016 MRI criteria with the aim of verifying their applicability in Sri Lankan patients. Patients with clinically isolated syndrome diagnosed by consultant neurologists were recruited from five major neurology centers. Baseline and follow-up MRI scans were performed within 3 months from the initial presentation and at one year after baseline MRI, respectively. McDonald 2010 and MAGNIMS 2016 MRI criteria were applied to all MRI scans. Patients were followed-up for 2 years to assess the conversion to clinically definite multiple sclerosis (CDMS). The sensitivity, specificity, accuracy, PPV, and NPV for predicting the conversion to CDMS were calculated. Forty-two of 66 patients converted to CDMS. Thirty-seven fulfilled the McDonald 2010 MRI criteria, and 33 converted to CDMS. MAGNIMS 2016 MRI criteria were fulfilled by 29, with 28 converting to CDMS. The sensitivity, specificity, accuracy, PPV, and NPV were 78%, 83%, 64%, 89%, and 69%, respectively, for the McDonald 2010 criteria, and 67%, 96%, 77%, 96%, and 62% for the MAGNIMS 2016 MRI criteria. MAGNIMS 2016 MRI criteria were superior to McDonald 2010 MRI criteria in specificity, accuracy, and PPV, but inferior in sensitivity and NPV. Copyright © 2018 Korean Neurological Association.

  5. The Atomic Energy Control Board criteria for identification and evaluation of fire hazards in nuclear power stations

    International Nuclear Information System (INIS)

    Morrison, Luke

    1986-03-01

    This report presents criteria for the identification and evaluation of fire hazards in nuclear power stations. The report presents criteria that are consistent with the existing regulatory approach in Canada, and outlines engineering tools and analytical techniques currently available to deterministically analyse fire. The criteria presented cover the topics which should be included in a fire hazard analysis and provide details of each topic so that the accuracy of an analysis may be evaluated

  6. Is there any evidence for the validity of diagnostic criteria used for accommodative and nonstrabismic binocular dysfunctions?

    Science.gov (United States)

    Cacho-Martínez, Pilar; García-Muñoz, Ángel; Ruiz-Cantero, María Teresa

    2014-01-01

    To analyze the diagnostic criteria used in the scientific literature published in the past 25 years for accommodative and nonstrabismic binocular dysfunctions and to explore if the epidemiological analysis of diagnostic validity has been used to propose which clinical criteria should be used for diagnostic purposes. We carried out a systematic review of papers on accommodative and non-strabic binocular disorders published from 1986 to 2012 analysing the MEDLINE, CINAHL, PsycINFO and FRANCIS databases. We admitted original articles about diagnosis of these anomalies in any population. We identified 839 articles and 12 studies were included. The quality of included articles was assessed using the QUADAS-2 tool. The review shows a wide range of clinical signs and cut-off points between authors. Only 3 studies (regarding accommodative anomalies) assessed diagnostic accuracy of clinical signs. Their results suggest using the accommodative amplitude and monocular accommodative facility for diagnosing accommodative insufficiency and a high positive relative accommodation for accommodative excess. The remaining 9 articles did not analyze diagnostic accuracy, assessing a diagnosis with the criteria the authors considered. We also found differences between studies in the way of considering patients' symptomatology. 3 studies of 12 analyzed, performed a validation of a symptom survey used for convergence insufficiency. Scientific literature reveals differences between authors according to diagnostic criteria for accommodative and nonstrabismic binocular dysfunctions. Diagnostic accuracy studies show that there is only certain evidence for accommodative conditions. For binocular anomalies there is only evidence about a validated questionnaire for convergence insufficiency with no data of diagnostic accuracy. Copyright © 2012 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  7. Insulated hsp70B' promoter: stringent heat-inducible activity in replication-deficient, but not replication-competent adenoviruses.

    Science.gov (United States)

    Rohmer, Stanimira; Mainka, Astrid; Knippertz, Ilka; Hesse, Andrea; Nettelbeck, Dirk M

    2008-04-01

    Key to the realization of gene therapy is the development of efficient and targeted gene transfer vectors. Therapeutic gene transfer by replication-deficient or more recently by conditionally replication-competent/oncolytic adenoviruses has shown much promise. For specific applications, however, it will be advantageous to provide vectors that allow for external control of gene expression. The efficient cellular heat shock system in combination with available technology for focused and controlled hyperthermia suggests heat-regulated transcription control as a promising tool for this purpose. We investigated the feasibility of a short fragment of the human hsp70B' promoter, with and without upstream insulator elements, for the regulation of transgene expression by replication-deficient or oncolytic adenoviruses. Two novel adenoviral vectors with an insulated hsp70B' promoter were developed and showed stringent heat-inducible gene expression with induction ratios up to 8000-fold. In contrast, regulation of gene expression from the hsp70B' promoter without insulation was suboptimal. In replication-competent/oncolytic adenoviruses regulation of the hsp70B' promoter was lost specifically during late replication in permissive cells and could not be restored by the insulators. We developed novel adenovirus gene transfer vectors that feature improved and stringent regulation of transgene expression from the hsp70B' promoter using promoter insulation. These vectors have potential for gene therapy applications that benefit from external modulation of therapeutic gene expression or for combination therapy with hyperthermia. Furthermore, our study reveals that vector replication can deregulate inserted cellular promoters, an observation which is of relevance for the development of replication-competent/oncolytic gene transfer vectors. (c) 2008 John Wiley & Sons, Ltd.

  8. Does dishonesty really invite third-party punishment? Results of a more stringent test.

    Science.gov (United States)

    Konishi, Naoki; Ohtsubo, Yohsuke

    2015-05-01

    Many experiments have demonstrated that people are willing to incur cost to punish norm violators even when they are not directly harmed by the violation. Such altruistic third-party punishment is often considered an evolutionary underpinning of large-scale human cooperation. However, some scholars argue that previously demonstrated altruistic third-party punishment against fairness-norm violations may be an experimental artefact. For example, envy-driven retaliatory behaviour (i.e. spite) towards better-off unfair game players may be misidentified as altruistic punishment. Indeed, a recent experiment demonstrated that participants ceased to inflict third-party punishment against an unfair player once a series of key methodological problems were systematically controlled for. Noticing that a previous finding regarding apparently altruistic third-party punishment against honesty-norm violations may have been subject to methodological issues, we used a different and what we consider to be a more sound design to evaluate these findings. Third-party punishment against dishonest players withstood this more stringent test. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  9. Accuracy Assessment of Different Digital Surface Models

    Directory of Open Access Journals (Sweden)

    Ugur Alganci

    2018-03-01

    Full Text Available Digital elevation models (DEMs, which can occur in the form of digital surface models (DSMs or digital terrain models (DTMs, are widely used as important geospatial information sources for various remote sensing applications, including the precise orthorectification of high-resolution satellite images, 3D spatial analyses, multi-criteria decision support systems, and deformation monitoring. The accuracy of DEMs has direct impacts on specific calculations and process chains; therefore, it is important to select the most appropriate DEM by considering the aim, accuracy requirement, and scale of each study. In this research, DSMs obtained from a variety of satellite sensors were compared to analyze their accuracy and performance. For this purpose, freely available Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER 30 m, Shuttle Radar Topography Mission (SRTM 30 m, and Advanced Land Observing Satellite (ALOS 30 m resolution DSM data were obtained. Additionally, 3 m and 1 m resolution DSMs were produced from tri-stereo images from the SPOT 6 and Pleiades high-resolution (PHR 1A satellites, respectively. Elevation reference data provided by the General Command of Mapping, the national mapping agency of Turkey—produced from 30 cm spatial resolution stereo aerial photos, with a 5 m grid spacing and ±3 m or better overall vertical accuracy at the 90% confidence interval (CI—were used to perform accuracy assessments. Gross errors and water surfaces were removed from the reference DSM. The relative accuracies of the different DSMs were tested using a different number of checkpoints determined by different methods. In the first method, 25 checkpoints were selected from bare lands to evaluate the accuracies of the DSMs on terrain surfaces. In the second method, 1000 randomly selected checkpoints were used to evaluate the methods’ accuracies for the whole study area. In addition to the control point approach, vertical cross

  10. Evaluation of WHO Criteria to Determine Degree of Dehydration in Children with Acute Diarrhea

    OpenAIRE

    Sari, Suprawita; Supriatmo; Margaretha, S. L.; Nafianti, S.; Hasibuan, B.; Sinuhaji, A. B.

    2005-01-01

    Objective To evaluate the diagnostic accuracy and agreement between the 1980 and 1990 WHO criteria for determining the degree of dehydration in children with acute diarrhea. Methods This prospective study was conducted in two hospitals from October 2002 to February 2003. Clinical signs of dehydration all patients were recorded. The degree of dehydration based on the 1980 and 1990 WHO criteria was determined and compared with fluid deficit measured by the difference of body weight on admiss...

  11. Comparison of Multi-Criteria Decision Support Methods (AHP, TOPSIS, SAW & PROMENTHEE) for Employee Placement

    Science.gov (United States)

    Widianta, M. M. D.; Rizaldi, T.; Setyohadi, D. P. S.; Riskiawan, H. Y.

    2018-01-01

    The right decision in placing employees in an appropriate position in a company will support the quality of management and will have an impact on improving the quality of human resources of the company. Such decision-making can be assisted by an approach through the Decision Support System (DSS) to improve accuracy in the employee placement process. The purpose of this paper is to compare the four methods of Multi Criteria Decision Making (MCDM), ie Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS), Simple Additive Weighting (SAW), Analytic Hierarchy Process (AHP) and Preference Ranking Organization Method for Enrichment Of Evaluations (PROMETHEE) for the application of employee placement in accordance with predetermined criteria. The ranking results and the accuracy level obtained from each method are different depending on the different scaling and weighting processes in each method.

  12. Potential of accuracy profile for method validation in inductively coupled plasma spectrochemistry

    International Nuclear Information System (INIS)

    Mermet, J.M.; Granier, G.

    2012-01-01

    Method validation is usually performed over a range of concentrations for which analytical criteria must be verified. One important criterion in quantitative analysis is accuracy, i.e. the contribution of both trueness and precision. The study of accuracy over this range is called an accuracy profile and provides experimental tolerance intervals. Comparison with acceptability limits fixed by the end user defines a validity domain. This work describes the computation involved in the building of the tolerance intervals, particularly for the intermediate precision with within-laboratory experiments and for the reproducibility with interlaboratory studies. Computation is based on ISO 5725‐4 and on previously published work. Moreover, the bias uncertainty is also computed to verify the bias contribution to accuracy. The various types of accuracy profile behavior are exemplified with results obtained by using ICP-MS and ICP-AES. This procedure allows the analyst to define unambiguously a validity domain for a given accuracy. However, because the experiments are time-consuming, the accuracy profile method is mainly dedicated to method validation. - Highlights: ► An analytical method is defined by its accuracy, i.e. both trueness and precision. ► The accuracy as a function of an analyte concentration is an accuracy profile. ► Profile basic concepts are explained for trueness and intermediate precision. ► Profile-based tolerance intervals have to be compared with acceptability limits. ► Typical accuracy profiles are given for both ICP-AES and ICP-MS techniques.

  13. Task Force on Catastrophic Antiphospholipid Syndrome (APS) and Non-criteria APS Manifestations (II): thrombocytopenia and skin manifestations.

    Science.gov (United States)

    Cervera, R; Tektonidou, M G; Espinosa, G; Cabral, A R; González, E B; Erkan, D; Vadya, S; Adrogué, H E; Solomon, M; Zandman-Goddard, G; Shoenfeld, Y

    2011-02-01

    The objectives of the 'Task Force on Catastrophic Antiphospholipid Syndrome (APS) and Non-criteria APS Manifestations' were to assess the clinical utility of the international consensus statement on classification criteria and treatment guidelines for the catastrophic APS, to identify and grade the studies that analyze the relationship between the antiphospholipid antibodies and the non-criteria APS manifestations, and to present the current evidence regarding the accuracy of these non-criteria APS manifestations for the detection of patients with APS. This article summarizes the studies analyzed on thrombocytopenia and skin manifestations, and presents the recommendations elaborated by the Task Force after this analysis.

  14. Establishing diagnostic cut-off criteria for the COBAS AmpliPrep/COBAS TaqMan HIV-1 Qualitative test through validation against the Amplicor DNA test v1.5 for infant diagnosis using dried blood spots.

    Science.gov (United States)

    Maritz, Jean; Preiser, Wolfgang; van Zyl, Gert U

    2012-02-01

    As antibody testing cannot confirm HIV-1 infection in children less than 18 months of age, diagnosis in these children depends on nucleic acid testing. The COBAS(®) AmpliPrep/COBAS(®) TaqMan(®) (CAP/CTM, Roche(®) Molecular Systems, Inc., Branchburg, NJ) HIV-1 Qualitative test is a total nucleic acid real-time PCR assay utilising whole EDTA blood or dried blood spots (DBS), which recently replaced the Roche(®) AMPLICOR(®) DNA test v1.5 (Amplicor) as the diagnostic HIV PCR assay in many South African laboratories. For the Amplicor assay, stringent diagnostic criteria were previously formulated for the local population, and a comparison reported the CAP/CTM's sensitivity at 99.7% and specificity at 100% for both sample types compared to these Amplicor criteria. To validate the assay prior to introduction in our laboratory and to define stringent diagnostic cut-off criteria. Whole EDTA blood samples from patients younger than 18 months sent for routine HIV-1 diagnosis were tested by Amplicor, and positive results were confirmed from DBS. CAP/CTM assays were subsequently performed from DBS. The CAP/CTM had a sensitivity of 98.8% and a specificity of 97.1%, but a positive predictive value (PPV) of only 78.7% compared to the Amplicor assay. Samples positive by CAP/CTM but negative by Amplicor displayed poor amplification curves compared to concordant positive samples. Upon re-testing those with sufficient material available by CAP/CTM, all showed negative results. The decreased PPV may either be due to false positive CAP/CTM results, or increased sensitivity compared to the Amplicor assay. Criteria were formulated for defining presumed false-positive results. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Evaluating radiographers' diagnostic accuracy in screen-reading mammograms: what constitutes a quality study?

    International Nuclear Information System (INIS)

    Debono, Josephine C; Poulos, Ann E

    2015-01-01

    The aim of this study was to first evaluate the quality of studies investigating the diagnostic accuracy of radiographers as mammogram screen-readers and then to develop an adapted tool for determining the quality of screen-reading studies. A literature search was used to identify relevant studies and a quality evaluation tool constructed by combining the criteria for quality of Whiting, Rutjes, Dinnes et al. and Brealey and Westwood. This constructed tool was then applied to the studies and subsequently adapted specifically for use in evaluating quality in studies investigating diagnostic accuracy of screen-readers. Eleven studies were identified and the constructed tool applied to evaluate quality. This evaluation resulted in the identification of quality issues with the studies such as potential for bias, applicability of results, study conduct, reporting of the study and observer characteristics. An assessment of the applicability and relevance of the tool for this area of research resulted in adaptations to the criteria and the development of a tool specifically for evaluating diagnostic accuracy in screen-reading. This tool, with further refinement and rigorous validation can make a significant contribution to promoting well-designed studies in this important area of research and practice

  16. Diagnostic Accuracy of Coronary CT Angiography for the Evaluation of Bioresorbable Vascular Scaffolds

    DEFF Research Database (Denmark)

    Collet, Carlos; Chevalier, Bernard; Cequier, Angel

    2018-01-01

    : 44 to 90) and a specificity of 82% (95% CI: 75 to 87). The diagnostic accuracy of coronary CTA was similar to coronary angiography in its ability to identify patients with a significant lesion based on the IVUS criteria (p = 0.75). CONCLUSIONS: Coronary CTA has good diagnostic accuracy to detect in-scaffold...... luminal obstruction and to assess luminal dimensions after BVS implantation. Coronary angiography and coronary CTA yielded similar diagnostic accuracy to identify the presence and severity of obstructive disease. Coronary CTA might become the method of choice for the evaluation of patients treated......OBJECTIVES: To assess the diagnostic accuracy of coronary computed tomography angiography (CTA) for bioresorbable vascular scaffold (BVS) evaluation. BACKGROUND: Coronary CTA has emerged as a noninvasive method to evaluate patients with suspected or established coronary artery disease...

  17. HARMONIZATION OF CRITERIA AND TERMINOLOGY IN RABBIT MEAT RESEARCH

    OpenAIRE

    Blasco Mateu, Agustín; Ouhayoun, J.; Masoero, G.

    1993-01-01

    [EN] The harmonization of rabbit carcass criteria is a result of an international work. lts task was to specify the main traits to be considerad from the birth of the animal to carcass analysis, to define these traits with enough accuracy and to propose a common terminology. Work on harmonization has been initialized by the Mediterranean Rabbit Group Conference (BLASCO, OUHAYOUN and MASOERO, 1992), completad by several research teams and, finally, discussed during a round...

  18. Accuracy of clinical diagnosis versus the World Health Organization case definition in the Amoy Garden SARS cohort.

    Science.gov (United States)

    Wong, W N; Sek, Antonio C H; Lau, Rick F L; Li, K M; Leung, Joe K S; Tse, M L; Ng, Andy H W; Stenstrom, Robert

    2003-11-01

    To compare the diagnostic accuracy of emergency department (ED) physicians with the World Health Organization (WHO) case definition in a large community-based SARS (severe acute respiratory syndrome) cohort. This was a cohort study of all patients from Hong Kong's Amoy Garden complex who presented to an ED SARS screening clinic during a 2-month outbreak. Clinical findings and WHO case definition criteria were recorded, along with ED diagnoses. Final diagnoses were established independently based on relevant diagnostic tests performed after the ED visit. Emergency physician diagnostic accuracy was compared with that of the WHO SARS case definition. Sensitivity, specificity, predictive values and likelihood ratios were calculated using standard formulae. During the study period, 818 patients presented with SARS-like symptoms, including 205 confirmed SARS, 35 undetermined SARS and 578 non-SARS. Sensitivity, specificity and accuracy were 91%, 96% and 94% for ED clinical diagnosis, versus 42%, 86% and 75% for the WHO case definition. Positive likelihood ratios (LR+) were 21.1 for physician judgement and 3.1 for the WHO criteria. Negative likelihood ratios (LR-) were 0.10 for physician judgement and 0.67 for the WHO criteria, indicating that clinician judgement was a much more powerful predictor than the WHO criteria. Physician clinical judgement was more accurate than the WHO case definition. Reliance on the WHO case definition as a SARS screening tool may lead to an unacceptable rate of misdiagnosis. The SARS case definition must be revised if it is to be used as a screening tool in emergency departments and primary care settings.

  19. Optimizing the accuracy of a helical diode array dosimeter: A comprehensive calibration methodology coupled with a novel virtual inclinometer

    Energy Technology Data Exchange (ETDEWEB)

    Kozelka, Jakub; Robinson, Joshua; Nelms, Benjamin; Zhang, Geoffrey; Savitskij, Dennis; Feygelman, Vladimir [Sun Nuclear Corp., Melbourne, Florida 32940 (United States); Department of Physics, University of South Florida, Tampa, Florida 33612 (United States); Canis Lupus LLC, Sauk County, Wisconsin 53561 (United States); Division of Radiation Oncology, Moffitt Cancer Center, Tampa, Florida 33612 (United States); Sun Nuclear Corp., Melbourne, Florida 32940 (United States); Division of Radiation Oncology, Moffitt Cancer Center, Tampa, Florida 33612 (United States)

    2011-09-15

    .3% for the 3%/3 mm and 2%/2 mm dose-error/distance to agreement threshold criteria, respectively, with the global dose-error normalization. With the local dose-error normalization, the average passing rates are reduced to 94.6 and 85.7% for the 3%/3 mm and 2%/2 mm criteria, respectively. Some algorithms in the convolution/superposition family are not sufficiently accurate in predicting the exit dose in the presence of a 15 cm diameter air cavity. Conclusions: Introduction of the improved calibration methodology, enabled by a robust virtual inclinometer algorithm, improves the accuracy of the dosimeter's absolute dose measurements. With our treatment planning and delivery chain, gamma analysis passing rates for the VMAT plans based on the AAPM TG-119 report are expected to be above 91% and average at about 95% level for {gamma}(3%/3 mm) with the local dose-error normalization. This stringent comparison methodology is more indicative of the true VMAT system commissioning accuracy compared to the often quoted dose-error normalization to a single high value.

  20. Content and accuracy of vaccine information on pediatrician blogs.

    Science.gov (United States)

    Bryan, Mersine A; Gunningham, Hailey; Moreno, Megan A

    2018-01-29

    Parents often use social media such as blogs to inform decisions about vaccinations, however little is known about pediatrician blogs addressing vaccines. The objective of this study was to assess content, citations, audience engagement and accuracy of vaccine information on pediatrician blogs. We conducted a content analysis of vaccine information on pediatrician blogs. A national sample of pediatrician blogs was identified using a search rubric of terms applied to multiple search engines. Inclusion criteria were: (1) the writer identified as a pediatrician (2) US based (3) ≥1 post since 1/1/2014. We identified 84 blogs; 56 fit inclusion criteria. Data were collected on all posts mentioning vaccines from 1/1/14 to 2/28/15. We identified the major topic for each post, examined citations to determine sources of information and counted the number of comments per post to evaluate audience engagement. We assessed accuracy of vaccine information using evaluation criteria adapted from information for parents on the CDC website. We identified 324 unique blog posts containing information about vaccines on 31 pediatrician blogs. The most common major topic was vaccine-specific posts (36%); Influenza and MMR were the most prevalent. Other common topics included: activism against anti-vaccine information (21%), vaccine exemptions (10%), autism (8%), and vaccine safety (6%). Activism against anti-vaccine information was the topic with the most reader engagement. The most common sources cited were governmental organizations such as the CDC and WHO (34%), and medical journals (31%). All blogs except 2 included information that was consistent with CDC information. Pediatrician bloggers frequently address vaccinations; most provide accurate information. Pediatrician blogs may be a new source to provide vaccine education to parents via social media. Copyright © 2017. Published by Elsevier Ltd.

  1. Requirements on the Redshift Accuracy for future Supernova and Number Count Surveys

    International Nuclear Information System (INIS)

    Huterer, Dragan; Kim, Alex; Broderick, Tamara

    2004-01-01

    We investigate the required redshift accuracy of type Ia supernova and cluster number-count surveys in order for the redshift uncertainties not to contribute appreciably to the dark energy parameter error budget. For the SNAP supernova experiment, we find that, without the assistance of ground-based measurements, individual supernova redshifts would need to be determined to about 0.002 or better, which is a challenging but feasible requirement for a low-resolution spectrograph. However, we find that accurate redshifts for z < 0.1 supernovae, obtained with ground-based experiments, are sufficient to immunize the results against even relatively large redshift errors at high z. For the future cluster number-count surveys such as the South Pole Telescope, Planck or DUET, we find that the purely statistical error in photometric redshift is less important, and that the irreducible, systematic bias in redshift drives the requirements. The redshift bias will have to be kept below 0.001-0.005 per redshift bin (which is determined by the filter set), depending on the sky coverage and details of the definition of the minimal mass of the survey. Furthermore, we find that X-ray surveys have a more stringent required redshift accuracy than Sunyaev-Zeldovich (SZ) effect surveys since they use a shorter lever arm in redshift; conversely, SZ surveys benefit from their high redshift reach only so long as some redshift information is available for distant (zgtrsim1) clusters

  2. FDG PET/CT diagnostic criteria may need adjustment based on MRI to estimate the presurgical risk of extrapelvic infiltration in patients with uterine endometrial cancer

    Energy Technology Data Exchange (ETDEWEB)

    Sudo, Satoko; Sakuragi, Noriaki [Hokkaido University Graduate School of Medicine, Department of Gynecology, Sapporo (Japan); Hattori, Naoya; Manabe, Osamu; Hirata, Kenji; Tamaki, Nagara [Hokkaido University Graduate School of Medicine, Department of Nuclear Medicine, Kitaku, Sapporo (Japan); Kato, Fumi; Mimura, Rie; Magota, Keiichi; Sugimori, Hiroyuki [Hokkaido University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Sapporo (Japan)

    2015-04-01

    The staging of endometrial cancer requires surgery which carries the risk of morbidity. FDG PET/CT combined with anatomical imaging may reduce the number of unnecessary lymphadenectomies by demonstrating the risk of extrapelvic infiltration. The purpose of this study was to optimize FDG PET/CT diagnostic criteria for risk assessment in endometrial cancer after first-line risk triage with MRI. The study population comprised 37 patients who underwent curative surgery for the treatment of endometrial cancer. First, the risk of extrapelvic infiltration was triaged using MRI. Second, multiple glucose metabolic profiles of the primary lesion were assessed with FDG PET/CT, and these were correlated with the histopathological risk of extrapelvic infiltration including lymphovascular space invasion (LVSI) and high-grade malignancy (grades 2 and 3). The results of histological correlation were used to adjust FDG PET/CT diagnostic criteria. Presurgical assessment using MRI was positive for deep (>50 %) myometrial invasion in 17 patients. The optimal FDG PET/CT diagnostic criteria vary depending on the results of MRI. Specifically, SUVmax (≥16.0) was used to indicate LVSI risk with an overall diagnostic accuracy of 88.2 % in patients with MRI findings showing myometrial invasion. High-grade malignancy did not correlate with any of metabolic profiles in this patient group. In the remaining patients without myometrial invasion, lesion glycolysis (LG) or metabolic volume were better indicators of LVSI than SUVmax with the same diagnostic accuracy of 80.0 %. In addition, LG (≥26.9) predicted high-grade malignancy with an accuracy of 72.2 %. Using the optimized cut-off criteria for LVSI, glucose metabolic profiling of primary lesions correctly predicted lymph node metastasis with an accuracy of 73.0 %, which was comparable with the accuracy of visual assessment for lymph node metastasis using MRI and FDG PET/CT. FDG PET/CT diagnostic criteria may need adjustment based on the

  3. Electronic apex locator: A comprehensive literature review — Part II: Effect of different clinical and technical conditions on electronic apex locator′s accuracy

    Directory of Open Access Journals (Sweden)

    Hamid Razavian

    2014-01-01

    Full Text Available Introduction: To investigate the effects of different clinical and technical conditions on the accuracy of electronic apex locators (EALs. Materials and Methods: "Tooth apex," "dental instrument," "odontometry," "electronic medical," and "electronic apex locator" were searched as primary identifiers via Medline/PubMed, Cochrane library, and Scopus data base up to 30 July 2013. Original articles that fulfilled the inclusion criteria were selected and reviewed. Results: Out of 402 relevant studies, 183 were selected based on the inclusion criteria. In this part, 75 studies are presented. Pulp vitality conditions and root resorption, types of files and irrigating materials do not affect an EAL′s accuracy; however, the file size and foramen diameter can affect its accuracy. Conclusions: Various clinical conditions such as the file size and foramen diameter may affect EALs′ accuracy. However, more randomized clinical trials are needed for definitive conclusion.

  4. American College of Rheumatology provisional criteria for defining clinical inactive disease in select categories of juvenile idiopathic arthritis.

    Science.gov (United States)

    Wallace, Carol A; Giannini, Edward H; Huang, Bin; Itert, Lukasz; Ruperto, Nicolino

    2011-07-01

    To prospectively validate the preliminary criteria for clinical inactive disease (CID) in patients with select categories of juvenile idiopathic arthritis (JIA). We used the process for development of classification and response criteria recommended by the American College of Rheumatology Quality of Care Committee. Patient-visit profiles were extracted from the phase III randomized controlled trial of infliximab in polyarticular-course JIA (i.e., patients considered to resemble those with select categories of JIA) and sent to an international group of expert physician raters. Using the physician ratings as the gold standard, the sensitivity and specificity were calculated using the preliminary criteria. Modifications to the criteria were made, and these were sent to a larger group of pediatric rheumatologists to determine quantitative, face, and content validity. Variables weighted heaviest by physicians when making their judgment were the number of joints with active arthritis, erythrocyte sedimentation rate (ESR), physician's global assessment, and duration of morning stiffness. Three modifications were made: the definition of uveitis, the definition of abnormal ESR, and the addition of morning stiffness. These changes did not alter the accuracy of the preliminary set. The modified criteria, termed the "criteria for CID in select categories of JIA," have excellent feasibility and face, content, criterion, and discriminant validity to detect CID in select categories of JIA. The small changes made to the preliminary criteria set did not alter the area under the receiver operating characteristic curve (0.954) or accuracy (91%), but have increased face and content validity. Copyright © 2011 by the American College of Rheumatology.

  5. The Leech method for diagnosing constipation: intra- and interobserver variability and accuracy

    International Nuclear Information System (INIS)

    Lorijn, Fleur de; Voskuijl, Wieger P.; Taminiau, Jan A.; Benninga, Marc A.; Rijn, Rick R. van; Henneman, Onno D.F.; Heijmans, Jarom; Reitsma, Johannes B.

    2006-01-01

    The data concerning the value of a plain abdominal radiograph in childhood constipation are inconsistent. Recently, positive results have been reported of a new radiographic scoring system, ''the Leech method'', for assessing faecal loading. To assess intra- and interobserver variability and determine diagnostic accuracy of the Leech method in identifying children with functional constipation (FC). A total of 89 children (median age 9.8 years) with functional gastrointestinal disorders were included in the study. Based on clinical parameters, 52 fulfilled the criteria for FC, six fulfilled the criteria for functional abdominal pain (FAP), and 31 for functional non-retentive faecal incontinence (FNRFI); the latter two groups provided the controls. To assess intra- and interobserver variability of the Leech method three scorers scored the same abdominal radiograph twice. A Leech score of 9 or more was considered as suggestive of constipation. ROC analysis was used to determine the diagnostic accuracy of the Leech method in separating patients with FC from control patients. Significant intraobserver variability was found between two scorers (P=0.005 and P<0.0001), whereas there was no systematic difference between the two scores of the other scorer (P=0.89). The scores between scorers differed systematically and displayed large variability. The area under the ROC curve was 0.68 (95% CI 0.58-0.80), indicating poor diagnostic accuracy. The Leech scoring method for assessing faecal loading on a plain abdominal radiograph is of limited value in the diagnosis of FC in children. (orig.)

  6. Accuracy and User Performance Evaluation of a New, Wireless-enabled Blood Glucose Monitoring System That Links to a Smart Mobile Device.

    Science.gov (United States)

    Bailey, Timothy S; Wallace, Jane F; Pardo, Scott; Warchal-Windham, Mary Ellen; Harrison, Bern; Morin, Robert; Christiansen, Mark

    2017-07-01

    The new Contour ® Plus ONE blood glucose monitoring system (BGMS) features an easy-to-use, wireless-enabled blood glucose meter that links to a smart mobile device via Bluetooth ® connectivity and can sync with the Contour ™ Diabetes app on a smartphone or tablet. The accuracy of the new BGMS was assessed in 2 studies according to ISO 15197:2013 criteria. In Study 1 (laboratory study), fingertip capillary blood samples from 100 subjects were tested in duplicate using 3 test strip lots. In Study 2 (clinical study), 134 subjects with type 1 or type 2 diabetes enrolled at 2 clinical sites. BGMS results and YSI analyzer (YSI) reference results were compared for fingertip blood obtained by untrained subjects' self-testing and for study staff-obtained fingertip, subject palm, and venous results. In Study 1, 99.0% (594/600) of combined results for all 3 test strip lots fulfilled ISO 15197:2013 Section 6.3 accuracy criteria. In Study 2, 99.2% (133/134) of subject-obtained capillary fingertip results, 99.2% (133/134) of study staff-obtained fingertip results, 99.2% (125/126) of subject-obtained palm results, and 100% (132/132) of study staff-obtained venous results met ISO 15197:2013 Section 8 accuracy criteria. Moreover, 95.5% (128/134) of subject-obtained fingertip self-test results were within ±10 mg/dl (±0.6 mmol/L) or ±10% of the YSI reference result. Questionnaire results showed that most subjects found the BGMS easy to use. The BGMS exceeded ISO 15197:2013 accuracy criteria both in the laboratory and in a clinical setting when used by untrained subjects with diabetes.

  7. Can imaging criteria distinguish enchondroma from grade 1 chondrosarcoma?

    Science.gov (United States)

    Crim, Julia; Schmidt, Robert; Layfield, Lester; Hanrahan, Christopher; Manaster, Betty Jean

    2015-11-01

    To minimize systematic bias and optimize agreement on imaging criteria in order to better define the accuracy of imaging criteria in the diagnosis of grade 1 chondrosarcoma. Study was IRB-approved and HIPAA compliant; informed consent was waived. Records were reviewed and disclosed 53 cases (38 women, 15 men ages 21-76) which were diagnosed as enchondroma or grade 1 chondrosarcoma and had available radiographs, contrast-enhanced MRI, and definitive diagnosis by histology or 5-year follow-up. 2 MSK radiologists read the studies independently after a session where they agreed on criteria for malignancy. Interobserver variability was determined as raw variability and with the kappa statistic. Accuracy was determined compared to final diagnosis. Reliability of imaging features of chondrosarcoma was determined using regression analysis. The correct diagnosis of enchondroma was made on radiographs in 43 (67.2%) of readings, and on MRI in 37/64 (57.8%). The correct diagnosis of chondrosarcoma was made on radiographs in 5/24 (20.8%) of readings, and on MRI in 14/24 (57.8%). A diagnosis of borderline lesion was made in 19/64 (29.7%) of enchondromas on radiographs and 18/64 (28.1%) on MRI. The false positive rate of radiographs for chondrosarcoma was 2/64 (3.1%) and the false positive rate of MRI was 9/64 (14.1%). There was substantial interobserver variability. Cortical thickening and bone expansion were rare but specific signs of chondrosarcoma. Both radiographs and MRI have limitations in the evaluation of low-grade cartilage lesions. MRI has an increased rate of both true-positive and false-positive diagnosis compared to radiographs. Differences in the findings of this study compared to previous literature may reflect the influence of systematic biases. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. Time line for noncopers to pass return-to-sports criteria after anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Hartigan, Erin H; Axe, Michael J; Snyder-Mackler, Lynn

    2010-03-01

    subgroup of noncopers require additional supervised rehabilitation to pass stringent criteria to return to sports. Therapy, level 2b.Note: If watching the first video, we recommend downloading and referring to the accompanying PowerPoint slides for any text that is not readable.

  9. Accuracy of physical diagnostic tests for assessing ruptures of the anterior curciate ligament: a meta-analysis.

    NARCIS (Netherlands)

    Scholten, R.J.P.M.; Opstelten, W.; Plas, C.G. van der; Bijl, D.; Devillé, W.L.J.M.; Bouter, L.M.

    2003-01-01

    OBJECTIVE: This systematic review summarizes the evidence on the accuracy of tests for assessing ACL ruptures of the knee. SEARCH STRATEGY: A computerized search of MEDLINE (1966-2003) and EMBASE (1980-2003) with additional reference tracking. SELECTION CRITERIA: Articles included were written in

  10. Prostatic MR imaging. Accuracy in differentiating cancer from other prostatic disorders

    Energy Technology Data Exchange (ETDEWEB)

    Ikonen, S.; Kivisaari, L.; Tervahartiala, P. [Helsinki Univ. Central Hospital (Finland). Dept of Radiology; Vehmas, T. [Finnish Inst. of Occupational Health, Helsinki (Finland); Taari, K.; Rannikko, S. [Helsinki Univ. Central Hospital (Finland). Dept of Urology

    2001-03-01

    Purpose: We assessed the accuracy of MR imaging in differentiating between cancer and other prostatic disorders, and evaluated the diagnostic criteria for various prostatic diseases. Material and Methods: A total of 74 endorectal coil MR studies were performed on 72 patients. Twenty patients had prostatic cancer, 20 benign prostatic hyperplasia (BPH), 4 acute bacterial prostatitis, 5 chronic bacterial prostatitis (2 also belonging to the previous category), 19 chronic non-bacterial prostatitis/chronic pelvic pain syndrome, and 6 were symptomless voluntary controls. All studies were interpreted by two experienced radiologists in random order. Radiologists were blinded to all clinical data including the age of the patients. Based on MR findings, both radiologists filled in a form covering diagnostic criteria and diagnosis. Results: Accuracy in diagnosing prostate cancer was 74%. Sensitivity was 50% and specificity 83%, and positive and negative predictive values were 53 and 82%, respectively. Bacterial prostatitis showed some features similar to carcinoma. Abundant BPH rendered cancer detection more difficult. No diagnostic criterion was clearly better than the others. Interobserver agreement on the MR diagnosis ranged from moderate to good. Conclusion: Without knowledge of accurate clinical data, MR seems to be too insensitive in detecting prostate cancer to be used as a primary diagnostic tool.

  11. Accuracy of Capillary and Arterial Whole Blood Glucose Measurements Using a Glucose Meter in Patients under General Anesthesia in the Operating Room.

    Science.gov (United States)

    Karon, Brad S; Donato, Leslie J; Larsen, Chelsie M; Siebenaler, Lindsay K; Wells, Amy E; Wood-Wentz, Christina M; Shirk-Marienau, Mary E; Curry, Timothy B

    2017-09-01

    The aim of this study was to evaluate the use of a glucose meter with surgical patients under general anesthesia in the operating room. Glucose measurements were performed intraoperatively on 368 paired capillary and arterial whole blood samples using a Nova StatStrip (Nova Biomedical, USA) glucose meter and compared with 368 reference arterial whole blood glucose measurements by blood gas analyzer in 196 patients. Primary outcomes were median bias (meter minus reference), percentage of glucose meter samples meeting accuracy criteria for subcutaneous insulin dosing as defined by Parkes error grid analysis for type 1 diabetes mellitus, and accuracy criteria for intravenous insulin infusion as defined by Clinical and Laboratory Standards Institute guidelines. Time under anesthesia, patient position, diabetes status, and other variables were studied to determine whether any affected glucose meter bias. Median bias (interquartile range) was -4 mg/dl (-9 to 0 mg/dl), which did not differ from median arterial meter bias of -5 mg/dl (-9 to -1 mg/dl; P = 0.32). All of the capillary and arterial glucose meter values met acceptability criteria for subcutaneous insulin dosing, whereas only 89% (327 of 368) of capillary and 93% (344 of 368) arterial glucose meter values met accuracy criteria for intravenous insulin infusion. Time, patient position, and diabetes status were not associated with meter bias. Capillary and arterial blood glucose measured using the glucose meter are acceptable for intraoperative subcutaneous insulin dosing. Whole blood glucose on the meter did not meet accuracy guidelines established specifically for more intensive (e.g., intravenous insulin) glycemic control in the acute care environment.

  12. Quantitative workflow based on NN for weighting criteria in landfill suitability mapping

    Science.gov (United States)

    Abujayyab, Sohaib K. M.; Ahamad, Mohd Sanusi S.; Yahya, Ahmad Shukri; Ahmad, Siti Zubaidah; Alkhasawneh, Mutasem Sh.; Aziz, Hamidi Abdul

    2017-10-01

    Our study aims to introduce a new quantitative workflow that integrates neural networks (NNs) and multi criteria decision analysis (MCDA). Existing MCDA workflows reveal a number of drawbacks, because of the reliance on human knowledge in the weighting stage. Thus, new workflow presented to form suitability maps at the regional scale for solid waste planning based on NNs. A feed-forward neural network employed in the workflow. A total of 34 criteria were pre-processed to establish the input dataset for NN modelling. The final learned network used to acquire the weights of the criteria. Accuracies of 95.2% and 93.2% achieved for the training dataset and testing dataset, respectively. The workflow was found to be capable of reducing human interference to generate highly reliable maps. The proposed workflow reveals the applicability of NN in generating landfill suitability maps and the feasibility of integrating them with existing MCDA workflows.

  13. Molecular tools for diagnosis of visceral leishmaniasis: systematic review and meta-analysis of diagnostic test accuracy

    NARCIS (Netherlands)

    de Ruiter, C. M.; van der Veer, C.; Leeflang, M. M. G.; Deborggraeve, S.; Lucas, C.; Adams, E. R.

    2014-01-01

    Molecular methods have been proposed as highly sensitive tools for the detection of Leishmania parasites in visceral leishmaniasis (VL) patients. Here, we evaluate the diagnostic accuracy of these tools in a meta-analysis of the published literature. The selection criteria were original studies that

  14. New diagnostic reporting format for endometrial cytology based on cytoarchitectural criteria

    Science.gov (United States)

    Yanoh, K; Norimatsu, Y; Hirai, Y; Takeshima, N; Kamimori, A; Nakamura, Y; Shimizu, K; Kobayashi, T K; Murata, T; Shiraishi, T

    2009-01-01

    Objective: The aim of this study was to develop a new reporting format for endometrial cytology that would standardize the diagnostic criteria and the terminology used for reporting. Methods: In previous studies, cytoarchitectural criteria were found to be useful for the cytological assessment of endometrial lesions. To apply these criteria, an appropriate cytological specimen is imperative. In this article, the requirements of an adequate endometrial cytological specimen for the new diagnostic criteria are first discussed. Then, the diagnostic criteria, standardized on a combination of conventional and cytoarchitectural criteria, are presented. Third, terminology that could be used, not only for reporting the histopathological diagnosis, but also for providing better guidance for the gynaecologist to determine further clinical action, is introduced. The proposed reporting format was investigated using endometrial cytology of 58 cases that were cytologically underestimated or overestimated compared to the histopathological diagnosis made on the subsequent endometrial biopsy or surgical specimens. Results: Of the 58 cases, 12 were reassessed as being unsatisfactory for evaluation. Among the remaining 46 cases, 25 of the 27 cases, which had been underestimated and subsequently diagnosed as having endometrial carcinoma or a precursor stage on histopathological examination,were reassessed as recommended for endometrial biopsy. On the other hand, 19 cases overestimated by cytology were all reassessed as not requiring biopsy. Conclusions: The reporting format for endometrial cytology proposed in this article may improve diagnostic accuracy and reduce the number of patients managed inappropriately. PMID:18657157

  15. Accuracy of Self-Esteem Judgments at Zero Acquaintance.

    Science.gov (United States)

    Hirschmüller, Sarah; Schmukle, Stefan C; Krause, Sascha; Back, Mitja D; Egloff, Boris

    2018-04-01

    Perceptions of strangers' self-esteem can have wide-ranging interpersonal consequences. Aiming to reconcile inconsistent results from previous research that had predominantly suggested that self-esteem is a trait that can hardly be accurately judged at zero acquaintance, we examined unaquainted others' accuracy in inferring individuals' actual self-esteem. Ninety-nine target participants (77 female; M age  = 23.5 years) were videotaped in a self-introductory situation, and self-esteem self-reports and reports by well-known informants were obtained as separate accuracy criteria. Forty unacquainted observers judged targets' self-esteem on the basis of these short video sequences (M = 23s, SD = 7.7). Results showed that both self-reported (r = .31, p = .002) and informant-reported self-esteem (r = .21, p = .040) of targets could be inferred by strangers. The degree of accuracy in self-esteem judgments could be explained with lens model analyses: Self- and informant-reported self-esteem predicted nonverbal and vocal friendliness, both of which predicted self-esteem judgments by observers. In addition, observers' accuracy in inferring informant-reported self-esteem was mediated by the utilization of targets' physical attractiveness. Besides using valid behavioral information to infer strangers' self-esteem, observers inappropriately relied on invalid behavioral information reflecting nonverbal, vocal, and verbal self-assuredness. Our findings show that strangers can quite accurately detect individuals' self-reported and informant-reported self-esteem when targets are observed in a public self-presentational situation. © 2017 Wiley Periodicals, Inc.

  16. The Leech method for diagnosing constipation: intra- and interobserver variability and accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Lorijn, Fleur de; Voskuijl, Wieger P.; Taminiau, Jan A.; Benninga, Marc A. [Emma Children' s Hospital, Department of Paediatric Gastroenterology and Nutrition, Amsterdam (Netherlands); Rijn, Rick R. van; Henneman, Onno D.F. [Academic Medical Centre, Department of Radiology, Amsterdam (Netherlands); Heijmans, Jarom [Emma Children' s Hospital, Department of Paediatric Gastroenterology and Nutrition, Amsterdam (Netherlands); Academic Medical Centre, Department of Radiology, Amsterdam (Netherlands); Reitsma, Johannes B. [Academic Medical Centre, Department of Clinical Epidemiology and Biostatistics, Amsterdam (Netherlands)

    2006-01-01

    The data concerning the value of a plain abdominal radiograph in childhood constipation are inconsistent. Recently, positive results have been reported of a new radiographic scoring system, ''the Leech method'', for assessing faecal loading. To assess intra- and interobserver variability and determine diagnostic accuracy of the Leech method in identifying children with functional constipation (FC). A total of 89 children (median age 9.8 years) with functional gastrointestinal disorders were included in the study. Based on clinical parameters, 52 fulfilled the criteria for FC, six fulfilled the criteria for functional abdominal pain (FAP), and 31 for functional non-retentive faecal incontinence (FNRFI); the latter two groups provided the controls. To assess intra- and interobserver variability of the Leech method three scorers scored the same abdominal radiograph twice. A Leech score of 9 or more was considered as suggestive of constipation. ROC analysis was used to determine the diagnostic accuracy of the Leech method in separating patients with FC from control patients. Significant intraobserver variability was found between two scorers (P=0.005 and P<0.0001), whereas there was no systematic difference between the two scores of the other scorer (P=0.89). The scores between scorers differed systematically and displayed large variability. The area under the ROC curve was 0.68 (95% CI 0.58-0.80), indicating poor diagnostic accuracy. The Leech scoring method for assessing faecal loading on a plain abdominal radiograph is of limited value in the diagnosis of FC in children. (orig.)

  17. On the problems relating to the accuracy of the measurement of fuel pin diameters by neutron radiography

    International Nuclear Information System (INIS)

    Matfield, R.

    1983-01-01

    The paper identifies the sources of error in the neutron radiographic system and attempts to estimate some of these errors. The sources of error are in the fuel pin materials, the radiographic set-up, the radiographic equipment, image formation, the microdensitometer, the edge criteria and the dimensional measurement from the microdensitometer trace. However, the critical problem area is that of determining a representative edge criteria and upon this will depend the ability of the method to achieve the required measurement accuracy. (Auth.)

  18. Cutting velocity accuracy as a criterion for comparing robot trajectories and manual movements for medical industry

    Science.gov (United States)

    Vorotnikov, A. A.; Klimov, D. D.; Romash, E. V.; Bashevskaya, O. S.; Poduraev, Yu. V.; Bazykyan, E. A.; Chunihin, A. A.

    2018-03-01

    Industrial robots perform technological operations, such as spot and arc welding, machining and laser cutting along different trajectories within their performance characteristics. The evaluation of these characteristics is carried out according to the criteria of the standard ISO 9283. The criteria of this standard are applicable in industrial manufacturing, but not in the medical industry, as they are not developed in the framework of medical tasks. Therefore, it is necessary to evaluate according to criteria built on different principles. In this article, the question of comparative evaluation of trajectories from program movements of a robot and manual movements of a surgeon, arising during the development of robotic medical complexes using industrial robots, is considered. A comparative evaluation is required to prove the expediency of automating medical operations in maxillofacial surgery. This study focuses on the estimation of velocity accuracy of a medical instrument. To obtain the velocity of the medical instrument, coordinates of the trajectory points from the program movements of the robot KUKA LWR4+ and trajectories from the manual movements of a professional surgeon have been measured. The measurement was carried out using a coordinate measuring machine, the laser tracker Leica LTD800. The accuracy estimation was carried out by two criteria: the criterion set out in the ISO 9283 standard, and the developed alternative criterion, the description of which is presented in this article. A quantitative comparative evaluation of the trajectories of a robot and a surgeon was obtained.

  19. HARMONIZATION OF CRITERIA AND TERMINOLOGY IN RABBIT MEAT RESEARCH. REVISED PROPOSAL

    OpenAIRE

    Blasco, A.; Ouhayoun, J.

    1996-01-01

    [EN] The harmonization of rabbit carcass criteria is a result of an international work. lts task was to specify the main traits to be considerad from the birth of the animal to the carcass analysis, to define these traits with enough accuracy and to propase a common terminology. The work concerns: 1- growth, consumption and breeding measurements, preslaughter handling and slaughter processing, 2- dressing out percentage analysis, 3- measurements or prediction of chillad a...

  20. Validation of the MDS research criteria for prodromal Parkinson's disease: Longitudinal assessment in a REM sleep behavior disorder (RBD) cohort.

    Science.gov (United States)

    Fereshtehnejad, Seyed-Mohammad; Montplaisir, Jacques Y; Pelletier, Amelie; Gagnon, Jean-François; Berg, Daniela; Postuma, Ronald B

    2017-06-01

    Recently, the International Parkinson and Movement Disorder Society introduced the prodromal criteria for PD. Objectives Our study aimed to examine diagnostic accuracy of the criteria as well as the independence of prodromal markers to predict conversion to PD or dementia with Lewy bodies. This prospective cohort study was performed on 121 individuals with rapid eye movement sleep behavior disorder who were followed annually for 1 to 12 years. Using data from a comprehensive panel of prodromal markers, likelihood ratio and post-test probability of the criteria were calculated at baseline and during each follow-up visit. Forty-eight (39.7%) individuals with rapid eye movement sleep behavior disorder converted to PD/dementia with Lewy bodies. The prodromal criteria had 81.3% sensitivity and 67.9% specificity for conversion to PD/dementia with Lewy bodies at 4-year follow-up. One year before conversion, sensitivity was 100%. The criteria predicted dementia with Lewy bodies with even higher accuracy than PD without dementia at onset. Those who met the threshold of prodromal criteria at baseline had significantly more rapid conversion into a neurodegenerative state (4.8 vs. 9.1 years; P conversion time in a rapid eye movement sleep behavior disorder cohort, with high sensitivity and high specificity with long follow-up. Prodromal markers influence the overall likelihood ratio independently, allowing them to be reliably multiplied. Defining additional markers with high likelihood ratio, further studies with longitudinal assessment and testing thresholds in different target populations will improve the criteria. © 2017 International Parkinson and Movement Disorder Society. © 2017 International Parkinson and Movement Disorder Society.

  1. A new accuracy measure based on bounded relative error for time series forecasting.

    Science.gov (United States)

    Chen, Chao; Twycross, Jamie; Garibaldi, Jonathan M

    2017-01-01

    Many accuracy measures have been proposed in the past for time series forecasting comparisons. However, many of these measures suffer from one or more issues such as poor resistance to outliers and scale dependence. In this paper, while summarising commonly used accuracy measures, a special review is made on the symmetric mean absolute percentage error. Moreover, a new accuracy measure called the Unscaled Mean Bounded Relative Absolute Error (UMBRAE), which combines the best features of various alternative measures, is proposed to address the common issues of existing measures. A comparative evaluation on the proposed and related measures has been made with both synthetic and real-world data. The results indicate that the proposed measure, with user selectable benchmark, performs as well as or better than other measures on selected criteria. Though it has been commonly accepted that there is no single best accuracy measure, we suggest that UMBRAE could be a good choice to evaluate forecasting methods, especially for cases where measures based on geometric mean of relative errors, such as the geometric mean relative absolute error, are preferred.

  2. Terminology and reporting criteria for radiofrequency ablation of tumors in the scientific literature: Systematic review of compliance with reporting standards

    International Nuclear Information System (INIS)

    Kang, Tae Wook; Rhim, Hyun Chul; Lee, Min Woo; Kim, Young Sun; Choi, Dongil; Lim, Hyo Keun

    2014-01-01

    To perform a systematic review of compliance with standardized terminology and reporting criteria for radiofrequency (RF) tumor ablation, proposed by the International Working Group on Image-Guided Tumor Ablation in 2003, in the published reports. Literature search in the PubMed database was performed using index keywords, PubMed limit system, and eligibility criteria. The entire content of each article was reviewed to assess the terminology used for procedure terms, imaging findings, therapeutic efficacy, follow-up, and complications. Accuracy of the terminology and the use of alternative terms instead of standard terminology were analyzed. In addition, disparities in accuracy of terminology in articles according to the medical specialty and the type of radiology journal were evaluated. Among the articles (n = 308) included in this study, the accuracy of the terms 'procedure or session', 'treatment', 'index tumor', 'ablation zone', 'technical success', 'primary technique effectiveness rate', 'secondary technique effectiveness rate', 'local tumor progression', 'major complication', and 'minor complication' was 97% (298/307), 97% (291/300), 8% (25/307), 65% (103/159), 55% (52/94), 33% (42/129), 94% (17/18), 45% (88/195), 99% (79/80), and 100% (77/77), respectively. The overall accuracy of each term showed a tendency to improve over the years. The most commonly used alternative terms for 'technical success' and 'local tumor progression' were 'complete ablation' and 'local (tumor) recurrence', respectively. The accuracy of terminology in articles published in radiology journals was significantly greater than that of terminology in articles published in non-radiology journals, especially in Radiology and The Journal of Vascular and Interventional Radiology. The proposal for standardization of terminology and reporting criteria for RF tumor ablation has been gaining support according to the recently published scientific reports, especially in the field of radiology

  3. Terminology and reporting criteria for radiofrequency ablation of tumors in the scientific literature: systematic review of compliance with reporting standards.

    Science.gov (United States)

    Kang, Tae Wook; Rhim, Hyunchul; Lee, Min Woo; Kim, Young-sun; Choi, Dongil; Lim, Hyo Keun

    2014-01-01

    To perform a systematic review of compliance with standardized terminology and reporting criteria for radiofrequency (RF) tumor ablation, proposed by the International Working Group on Image-Guided Tumor Ablation in 2003, in the published reports. Literature search in the PubMed database was performed using index keywords, PubMed limit system, and eligibility criteria. The entire content of each article was reviewed to assess the terminology used for procedure terms, imaging findings, therapeutic efficacy, follow-up, and complications. Accuracy of the terminology and the use of alternative terms instead of standard terminology were analyzed. In addition, disparities in accuracy of terminology in articles according to the medical specialty and the type of radiology journal were evaluated. Among the articles (n = 308) included in this study, the accuracy of the terms 'procedure or session', 'treatment', 'index tumor', 'ablation zone', 'technical success', 'primary technique effectiveness rate', 'secondary technique effectiveness rate', 'local tumor progression', 'major complication', and 'minor complication' was 97% (298/307), 97% (291/300), 8% (25/307), 65% (103/159), 55% (52/94), 33% (42/129), 94% (17/18), 45% (88/195), 99% (79/80), and 100% (77/77), respectively. The overall accuracy of each term showed a tendency to improve over the years. The most commonly used alternative terms for 'technical success' and 'local tumor progression' were 'complete ablation' and 'local (tumor) recurrence', respectively. The accuracy of terminology in articles published in radiology journals was significantly greater than that of terminology in articles published in non-radiology journals, especially in Radiology and The Journal of Vascular and Interventional Radiology. The proposal for standardization of terminology and reporting criteria for RF tumor ablation has been gaining support according to the recently published scientific reports, especially in the field of radiology

  4. Investigation of the Stress Intensity Limits of ASME Section III Div.5 for Structure Design Criteria of SFR Fuel Assembly

    International Nuclear Information System (INIS)

    Choo, Jin-Yup; Kim, Hyung-Kyu; Cheon, Jin-Sik

    2017-01-01

    In this paper, the stress intensity limits, Sm and St of HT-9 were built for the structural criteria of an SFR fuel assembly. Sm is obtained from the ultimate strength. As for St, it is more complicated because of its dependency of time duration in addition to temperature. Following the definition of Smt, the method in the ASME Sec. III Div. 1, Subsec. NH was consulted. We found that the Sm is adopted as Smt under the temperature about 470 .deg. C which is relatively low temperature range and over 470 .deg. C with relatively short time duration as 1000 hours. And the St is adopted as Smt at over 470 .deg. C and long time duration over 34800 hours, and over 520 .deg. C and 104 hours too. And at over 570 .deg. C and 1000 hours, and at over 630 .deg. C and 100 hours, St is also adopted for Smt. To use the present result as design criteria, a stringent examination needs to be carried out, because those are calculated from the formulae of HT-9 without an experimental validation. Therefore, an experimental work on the mechanical properties of HT-9 will be necessary.

  5. Accuracy of chest radiographs in the emergency diagnosis of heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Studler, Ueli; Kretzschmar, Martin; Steinbrich, Wolfgang [University Hospital Basel, Department of Radiology, Basel (Switzerland); Christ, Michael; Breidthardt, Tobias; Noveanu, Markus; Perruchoud, Andre P.; Mueller, Christian [University Hospital Basel, Department of Internal Medicine, Basel (Switzerland); Schoetzau, Andreas [Institute of Biostatistics, Basel (Switzerland)

    2008-08-15

    The purpose of this study was to determine the diagnostic accuracy of chest radiographic findings of heart failure (HF) in current patients presenting with dyspnea in the emergency department. In a secondary analysis of the BASEL study, initial chest radiographs of 277 patients with acute dyspnea were evaluated by two radiologists blinded to the adjudicated diagnosis (56% had the final diagnosis of HF). Predefined radiographic criteria of HF were used. Statistical analysis included receiver-operating characteristic (ROC) analysis and calculation of a logistic regression model including B-type natriuretic peptide (BNP) levels. The reader's overall impression showed the highest area under the ROC curve for the diagnosis of HF in both supine and erect patient positions (0.855 and 0.857). Among individual radiographic findings, peribronchial cuffing in the supine position (0.829) showed the highest accuracies. The lowest accuracy was found for the vascular pedicle width in the supine position (0.461). Logistic regression analysis showed no significant differences between the reader's overall impression, the radiographic model, and BNP testing. In our study, the combination of radiographic features provided valuable information and was of comparable accuracy as BNP-testing for the diagnosis of HF. (orig.)

  6. Validation criteria of an internal dosimetry laboratory in vivo

    International Nuclear Information System (INIS)

    Alfaro L, M. de las M.

    2014-10-01

    People working with radioactive materials, under certain circumstances (e.g. not using the proper protective equipment, an incident not covered, etc.) could be incorporated into the body. The radiation protection programs include direct measurement methods -in vivo- or indirect -in vitro- or both, to know that radioactive material is incorporated into the body. The monitoring measurements of internal contamination or (Radio-bioassay) are carried out with the purpose of determining the amount of radioactive material incorporated in the body; estimate the effective dose and committed dose; management administration of radiation protection; appropriate medical management; and to provide the data necessary for the legal requirements and the preservation of records. The measurement methods used in the monitoring of internal contamination must be validated by the combination of the following processes: calibration, using standards reference materials and/or simulators; execute systematic research, using control samples; and intercomparison between laboratories and performance tests. In this paper the validation criteria of an internal dosimetry laboratory in vivo are presented following the information provided by the standard ANSI N13-30-1996 and ISO/TEC 17025-2005 as are the criteria of facilities, staff training, interpretation of measurements, performance criteria for monitoring of internal contamination in vivo, results reporting and records retention. Thereby we achieve standardized quantitative performance criteria of truthfulness, accuracy and detection limit and a consensus on statistical definitions to establish the validation plan of a monitoring laboratory of internal contamination in vivo. (Author)

  7. A GIS-based extended fuzzy multi-criteria evaluation for landslide susceptibility mapping.

    Science.gov (United States)

    Feizizadeh, Bakhtiar; Shadman Roodposhti, Majid; Jankowski, Piotr; Blaschke, Thomas

    2014-12-01

    Landslide susceptibility mapping (LSM) is making increasing use of GIS-based spatial analysis in combination with multi-criteria evaluation (MCE) methods. We have developed a new multi-criteria decision analysis (MCDA) method for LSM and applied it to the Izeh River basin in south-western Iran. Our method is based on fuzzy membership functions (FMFs) derived from GIS analysis. It makes use of nine causal landslide factors identified by local landslide experts. Fuzzy set theory was first integrated with an analytical hierarchy process (AHP) in order to use pairwise comparisons to compare LSM criteria for ranking purposes. FMFs were then applied in order to determine the criteria weights to be used in the development of a landslide susceptibility map. Finally, a landslide inventory database was used to validate the LSM map by comparing it with known landslides within the study area. Results indicated that the integration of fuzzy set theory with AHP produced significantly improved accuracies and a high level of reliability in the resulting landslide susceptibility map. Approximately 53% of known landslides within our study area fell within zones classified as having "very high susceptibility", with the further 31% falling into zones classified as having "high susceptibility".

  8. Benchmarking whole-building energy performance with multi-criteria technique for order preference by similarity to ideal solution using a selective objective-weighting approach

    International Nuclear Information System (INIS)

    Wang, Endong

    2015-01-01

    Highlights: • A TOPSIS based multi-criteria whole-building energy benchmarking is developed. • A selective objective-weighting procedure is used for a cost-accuracy tradeoff. • Results from a real case validated the benefits of the presented approach. - Abstract: This paper develops a robust multi-criteria Technique for Order Preference by Similarity to Ideal Solution (TOPSIS) based building energy efficiency benchmarking approach. The approach is explicitly selective to address multicollinearity trap due to the subjectivity in selecting energy variables by considering cost-accuracy trade-off. It objectively weights the relative importance of individual pertinent efficiency measuring criteria using either multiple linear regression or principal component analysis contingent on meta data quality. Through this approach, building energy performance is comprehensively evaluated and optimized. Simultaneously, the significant challenges associated with conventional single-criterion benchmarking models can be avoided. Together with a clustering algorithm on a three-year panel dataset, the benchmarking case of 324 single-family dwellings demonstrated an improved robustness of the presented multi-criteria benchmarking approach over the conventional single-criterion ones

  9. Prospective analysis of magnetic resonance imaging accuracy in diagnosing traumatic injuries of the posterior ligamentous complex of the thoracolumbar spine.

    Science.gov (United States)

    Pizones, Javier; Sánchez-Mariscal, Felisa; Zúñiga, Lorenzo; Álvarez, Patricia; Izquierdo, Enrique

    2013-04-20

    Prospective cohort study. To study magnetic resonance imaging (MRI) accuracy in diagnosing posterior ligamentous complex (PLC) damage, when applying the new dichotomic instability criteria in a prospective cohort of patients with vertebral fracture. Recent studies dispute MRI accuracy to diagnose PLC injuries. They analyze the complex based on 3 categories (intact/indeterminate/rupture), including the indeterminate in the ruptured group (measurement bias) in the accuracy analysis. Moreover, fractures with conservative treatment (selection bias) are not included. Both facts reduce the specificity. A recent study has proposed new criteria where posterior instability is determined with supraspinous ligament (SSL) rupture. Prospective study of patients with acute thoracolumbar fracture, using radiography and MRI (FS-T2-w/short-tau inversion-recovery sequences). 1. The integrity (ruptured/unruptured) of each isolated component of the PLC (facet capsules, interspinous ligament, SSL, and ligamentum flavum) was assessed via MRI and surgical findings. 2. PLC integrity as a whole was assessed, adopting the new dichotomic stability criteria from previous studies. In the MR images, PLC is considered ruptured when the SSL is found discontinued, and intact when not (this excludes the "indeterminate" category). In surgically treated fractures, PLC stability as a whole was assessed dynamically (ruptured/unruptured). In conservative fractures, PLC stability was assessed according to change in vertebral kyphosis measured with the local kyphotic angle at 2-year follow-up (ruptured if difference is > 5°/unruptured if difference is PLC damage. Fifty-eight vertebral fractures were studied (38 surgical, 20 conservative), of which 50% were in males; average age, 40.4 years. MRI sensitivity for injury diagnosis of each isolated PLC component varied between 92.3% (interspinous ligament) and 100% (ligamentum flavum). Specificity varied between 52% (facet capsules) and 100% (SSL). PLC

  10. Accuracy of Methotrexate Use in Rheumatoid Arthritis Patients in Emanuel Klampok Hospital based on Explicit Criteria

    Directory of Open Access Journals (Sweden)

    Rizki Puspitasari

    2014-09-01

    Full Text Available Methotrexate (MTX is the first line therapy for rheumatoid arthritis (RA as an antiinflammatory and immunosuppressant agent. The purpose of this study was to evaluate the use of MTX in patients with rheumatoid arthritis at Emanuel Klampok Hospital based on criteria, including the indication, process indicators, complication, and outcome indicators. The medical record from 13 inpatients and 27 outpatients who used MTX were compared with the criteria. The results of this study demonstrated that all of the patients had appropriately indications to use MTX. Patients with risk factors that lead to GI disorders, hepatotoxicity, and bone marrow toxicity were 35 patients, 19 patients, and 15 patients respectively. There were 32 patients used MTX with the correct dosage, meanwhile incorrect dosage was showed in 3 patients with ClCr 61–80 mL/minute, 2 patients with ClCr 51–60 mL/minute, 1 patient with ClCr 10–50 mL/minute, and 2 patients with SGPT >3 normal value. The interaction with NSAID was happened in 35 patients and the interaction with hepatotoxicity agents in 19 patients. Complication occurred in 7 patients with effects that occur were GI disorders and 1 patient with chirrosis. There were 10 patients with clinical complaints reduced and 2 patients with the better condition. Indication of use MTX had appropriately, but process indicators, complication, and outcome indicators still not appropriate.

  11. Effects of accuracy motivation and anchoring on metacomprehension judgment and accuracy.

    Science.gov (United States)

    Zhao, Qin

    2012-01-01

    The current research investigates how accuracy motivation impacts anchoring and adjustment in metacomprehension judgment and how accuracy motivation and anchoring affect metacomprehension accuracy. Participants were randomly assigned to one of six conditions produced by the between-subjects factorial design involving accuracy motivation (incentive or no) and peer performance anchor (95%, 55%, or no). Two studies showed that accuracy motivation did not impact anchoring bias, but the adjustment-from-anchor process occurred. Accuracy incentive increased anchor-judgment gap for the 95% anchor but not for the 55% anchor, which induced less certainty about the direction of adjustment. The findings offer support to the integrative theory of anchoring. Additionally, the two studies revealed a "power struggle" between accuracy motivation and anchoring in influencing metacomprehension accuracy. Accuracy motivation could improve metacomprehension accuracy in spite of anchoring effect, but if anchoring effect is too strong, it could overpower the motivation effect. The implications of the findings were discussed.

  12. Evaluating the Quality, Accuracy, and Readability of Online Resources Pertaining to Hallux Valgus.

    Science.gov (United States)

    Tartaglione, Jason P; Rosenbaum, Andrew J; Abousayed, Mostafa; Hushmendy, Shazaan F; DiPreta, John A

    2016-02-01

    The Internet is one of the most widely utilized resources for health-related information. Evaluation of the medical literature suggests that the quality and accuracy of these resources are poor and written at inappropriately high reading levels. The purpose of our study was to evaluate the quality, accuracy, and readability of online resources pertaining to hallux valgus. Two search terms ("hallux valgus" and "bunion") were entered into Google, Yahoo, and Bing. With the use of scoring criteria specific to hallux valgus, the quality and accuracy of online information related to hallux valgus was evaluated by 3 reviewers. The Flesch-Kincaid score was used to determine readability. Statistical analysis was performed with t tests and significance was determined by P values hallux valgus" (P = .045). Quality and accuracy were significantly higher in resources authored by physicians as compared to nonphysicians (quality, P = .04; accuracy, P hallux valgus is poor and written at inappropriate reading levels. Furthermore, the search term used, authorship, and presence of commercial bias influence the value of these materials. It is important for orthopaedic surgeons to become familiar with patient education materials, so that appropriate recommendations can be made regarding valuable resources. Level IV. © 2015 The Author(s).

  13. Modified Kenneth Jones criteria for diagnosing tuberculous meningitis in children

    International Nuclear Information System (INIS)

    Anwar, M.; Ahmad, A.; Ahmad, F.; Mazhar, A.

    2010-01-01

    To evaluate accuracy of modified Kenneth Jones scoring criteria (MKJSC) as a screening tool to diagnose tuberculous meningitis in children. Study Design: Cross-sectional study. Place and Duration of Study: Paediatric Medicine, Unit-I, Bahawal Victoria Hospital, Bahawalpur, from May 2006 to March 2007. Methodology: A total of 100 children admitted through emergency in Paediatric Medicine, Unit-I, were included who were having fever and features suggestive of central nervous system (CNS) infection. Lumbar puncture was done in all patients after written consent. Findings of lumbar puncture were taken as gold standard for the diagnosis of TBM. MKJSC was applied on each patient and accuracy determined against the gold standard. Results: Out of 100 children, 47 were diagnosed as TBM on the basis of CSF results. All children had scored 0-7 or above according to MKJSC. A score 1-2, 3-4, 5-6 and 7 or more was obtained in 23, 25, 30 and 22 children respectively. Children who had scored 5 or more received ATT. Accuracy of MKJSC was calculated to be 91%. Conclusion: MKJSC is a simple and accurate tool to improve tuberculous meningitis case detection rate in children. (author)

  14. MR staging accuracy for endometrial cancer based on the new FIGO stage

    International Nuclear Information System (INIS)

    Shin, Kyung Eun; Park, Byung Kwan; Kim, Chan Kyo; Bae, Duk Soo; Song, Sang Yong; Kim, Bohyun

    2011-01-01

    Background: Magnetic resonance imaging (MRI) has been frequently used to determine a preoperative treatment plan for gynecologic cancers. However, the MR accuracy for staging an endometrial cancer is not satisfactory based on the old FIGO staging system. Purpose: To evaluate MR accuracy for staging endometrial cancer using the new FIGO staging system. Material and Methods: Between January 2005 and May 2009, 199 women underwent surgery due to endometrial cancer. In each patient, an endometrial cancer was staged using MR findings based on the old FIGO staging system and then repeated according to the new FIGO staging system for comparison. Histopathologic findings were used as a standard of reference. Results: The accuracy of MRI in the staging of endometrial carcinoma stage I, II, III, and IV using the old FIGO staging system were 80% (159/199), 89% (178/199), 90% (179/199), and 99% (198/199), respectively, compared to 87% (174/199), 97% (193/199), 90% (179/199), and 99% (198/199), respectively, when using the new FIGO staging criteria. The overall MR accuracy of the old and new staging systems were 51% (101/199) and 81% (161/199), respectively. Conclusion: MRI has become a more useful tool in the preoperative staging of endometrial cancers using the new FIGO staging system compared to the old one with increased accuracy

  15. Task Force on Catastrophic Antiphospholipid Syndrome (APS) and Non-criteria APS Manifestations (I): catastrophic APS, APS nephropathy and heart valve lesions.

    Science.gov (United States)

    Cervera, R; Tektonidou, M G; Espinosa, G; Cabral, A R; González, E B; Erkan, D; Vadya, S; Adrogué, H E; Solomon, M; Zandman-Goddard, G; Shoenfeld, Y

    2011-02-01

    The objectives of the 'Task Force on Catastrophic Antiphospholipid Syndrome (APS) and Non-criteria APS Manifestations' were to assess the clinical utility of the international consensus statement on classification criteria and treatment guidelines for the catastrophic APS, to identify and grade the studies that analyse the relationship between the antiphospholipid antibodies and the non-criteria APS manifestations and to present the current evidence regarding the accuracy of these non-criteria APS manifestations for the detection of patients with APS. This article summarizes the studies analysed on the catastrophic APS, APS nephropathy and heart valve lesions, and presents the recommendations elaborated by the Task Force after this analysis.

  16. Cost and quality effectiveness of objective-based and statistically-based quality control for volatile organic compounds analyses of gases

    International Nuclear Information System (INIS)

    Bennett, J.T.; Crowder, C.A.; Connolly, M.J.

    1994-01-01

    Gas samples from drums of radioactive waste at the Department of Energy (DOE) Idaho National Engineering Laboratory are being characterized for 29 volatile organic compounds to determine the feasibility of storing the waste in DOE's Waste Isolation Pilot Plant (WIPP) in Carlsbad, New Mexico. Quality requirements for the gas chromatography (GC) and GC/mass spectrometry chemical methods used to analyze the waste are specified in the Quality Assurance Program Plan for the WIPP Experimental Waste Characterization Program. Quality requirements consist of both objective criteria (data quality objectives, DQOs) and statistical criteria (process control). The DQOs apply to routine sample analyses, while the statistical criteria serve to determine and monitor precision and accuracy (P ampersand A) of the analysis methods and are also used to assign upper confidence limits to measurement results close to action levels. After over two years and more than 1000 sample analyses there are two general conclusions concerning the two approaches to quality control: (1) Objective criteria (e.g., ± 25% precision, ± 30% accuracy) based on customer needs and the usually prescribed criteria for similar EPA- approved methods are consistently attained during routine analyses. (2) Statistical criteria based on short term method performance are almost an order of magnitude more stringent than objective criteria and are difficult to satisfy following the same routine laboratory procedures which satisfy the objective criteria. A more cost effective and representative approach to establishing statistical method performances criteria would be either to utilize a moving average of P ampersand A from control samples over a several month time period or to determine within a sample variation by one-way analysis of variance of several months replicate sample analysis results or both. Confidence intervals for results near action levels could also be determined by replicate analysis of the sample in

  17. The diagnostic accuracy of serological tests for Lyme borreliosis in Europe

    DEFF Research Database (Denmark)

    Leeflang, M M G; Ang, C W; Berkhout, J

    2016-01-01

    -eight studies evaluating an Enzyme-Linked ImmunoSorbent assay (ELISA) or an immunoblot assay against a reference standard of clinical criteria were included. None of the studies had low risk of bias for all QUADAS-2 domains. Sensitivity was highly heterogeneous, with summary estimates: erythema migrans 50 % (95......BACKGROUND: Interpretation of serological assays in Lyme borreliosis requires an understanding of the clinical indications and the limitations of the currently available tests. We therefore systematically reviewed the accuracy of serological tests for the diagnosis of Lyme borreliosis in Europe....... We used a hierarchical summary ROC meta-regression method for the meta-analyses. Potential sources of heterogeneity were test-type, commercial or in-house, Ig-type, antigen type and study quality. These were added as covariates to the model, to assess their effect on test accuracy. RESULTS: Seventy...

  18. Qualification criteria verification for aisi-4340 steel suspension lug

    International Nuclear Information System (INIS)

    Riaz, M.A.; Alam, M.

    2005-01-01

    All external loads carried underneath an aircraft are mounted onto it through mechanism generally known as suspension system. The externally mounted attachments like bombs, missiles and fuel tanks etc. experience enormous aerodynamic and inertial forces in the flights. These forces are transferred to the interface point of suspension system, known as 'Suspension Lug'. Thus lugs are considered critical component and have extremely stringent qualification criteria standards used in the aviation industry in USA, Europe, Russia, etc. Different standards prevail in different parts of the world about qualification and testing of these lugs. As Pakistan is entering into aviation industry, therefore there is a need to fulfill the requirements of these standards, to suit Pakistani environment. The suspension lug under study is 2000 Ibs. load class made from AISI-4340 Steel having good mechanical properties as per required standard. The manufacturing processes included forging, machining and vacuum heat treatment. The prototypes of suspension lugs were manufactured in the local industry and subjected to the required mechanical tests such as tensile testing at 5 to 35 degree angles. Impact testing at cryogenic temperatures of -50 to -70 degree C, and breaking load testing were performed. The acceptable results were obtained and mechanical testing for qualification of lugs was finalized and standardized. The options were compared with practical viability, utilization of product and cost effectiveness. (author)

  19. Diagnostic accuracy of scapular physical examination tests for shoulder disorders: a systematic review.

    Science.gov (United States)

    Wright, Alexis A; Wassinger, Craig A; Frank, Mason; Michener, Lori A; Hegedus, Eric J

    2013-09-01

    To systematically review and critique the evidence regarding the diagnostic accuracy of physical examination tests for the scapula in patients with shoulder disorders. A systematic, computerised literature search of PubMED, EMBASE, CINAHL and the Cochrane Library databases (from database inception through January 2012) using keywords related to diagnostic accuracy of physical examination tests of the scapula. The Quality Assessment of Diagnostic Accuracy Studies tool was used to critique the quality of each paper. Eight articles met the inclusion criteria; three were considered to be of high quality. Of the three high-quality studies, two were in reference to a 'diagnosis' of shoulder pain. Only one high-quality article referenced specific shoulder pathology of acromioclavicular dislocation with reported sensitivity of 71% and 41% for the scapular dyskinesis and SICK scapula test, respectively. Overall, no physical examination test of the scapula was found to be useful in differentially diagnosing pathologies of the shoulder.

  20. Diagnostic accuracy of apparent diffusion coefficient and 123I-metaiodobenzylguanidine for differentiation of multiple system atrophy and Parkinson's disease.

    Directory of Open Access Journals (Sweden)

    Atsushi Umemura

    Full Text Available BACKGROUND: It is often hard to differentiate Parkinson's disease (PD and parkinsonian variant of multiple system atrophy (MSA-P, especially in the early stages. Cardiac sympathetic denervation and putaminal rarefaction are specific findings for PD and MSA-P, respectively. PURPOSE: We investigated diagnostic accuracy of putaminal apparent diffusion coefficient (ADC test for MSA-P and (123I-metaiodobenzylguanidine (MIBG scintigram for PD, especially in early-stage patients. METHODS: The referral standard diagnosis of PD and MSA-P were the diagnostic criteria of the United Kingdom Parkinson's Disease Society Brain Bank Criteria and the second consensus criteria, respectively. Based on the referral standard criteria, diagnostic accuracy [area under the receiver-operator characteristic curve (AUC, sensitivity and specificity] of the ADC and MIBG tests was estimated retrospectively. Diagnostic accuracy of these tests performed within 3 years of symptom onset was also investigated. RESULTS: ADC and MIBG tests were performed on 138 patients (20 MSA and 118 PD. AUC was 0.95 and 0.83 for the ADC and MIBG tests, respectively. Sensitivity and specificity were 85.0% and 89.0% for MSA-P diagnosis by ADC test and 67.0% and 80.0% for PD diagnosis by MIBG test. When these tests were restricted to patients with disease duration ≤ 3 years, the sensitivity and specificity were 75.0% and 91.4% for the ADC test (MSA-P diagnosis and 47.7% and 92.3% for the MIBG test (PD diagnosis. CONCLUSIONS: Both tests were useful in differentiating between PD and MSA-P, even in the early stages. In early-stage patients, elevated putaminal ADC was a diagnostic marker for MSA-P. Despite high specificity of the MIBG test, careful neurological history and examinations were required for PD diagnosis because of possible false-negative results.

  1. Diagnostic accuracy of apparent diffusion coefficient and 123I-metaiodobenzylguanidine for differentiation of multiple system atrophy and Parkinson's disease.

    Science.gov (United States)

    Umemura, Atsushi; Oeda, Tomoko; Hayashi, Ryutaro; Tomita, Satoshi; Kohsaka, Masayuki; Yamamoto, Kenji; Sawada, Hideyuki

    2013-01-01

    It is often hard to differentiate Parkinson's disease (PD) and parkinsonian variant of multiple system atrophy (MSA-P), especially in the early stages. Cardiac sympathetic denervation and putaminal rarefaction are specific findings for PD and MSA-P, respectively. We investigated diagnostic accuracy of putaminal apparent diffusion coefficient (ADC) test for MSA-P and (123)I-metaiodobenzylguanidine (MIBG) scintigram for PD, especially in early-stage patients. The referral standard diagnosis of PD and MSA-P were the diagnostic criteria of the United Kingdom Parkinson's Disease Society Brain Bank Criteria and the second consensus criteria, respectively. Based on the referral standard criteria, diagnostic accuracy [area under the receiver-operator characteristic curve (AUC), sensitivity and specificity] of the ADC and MIBG tests was estimated retrospectively. Diagnostic accuracy of these tests performed within 3 years of symptom onset was also investigated. ADC and MIBG tests were performed on 138 patients (20 MSA and 118 PD). AUC was 0.95 and 0.83 for the ADC and MIBG tests, respectively. Sensitivity and specificity were 85.0% and 89.0% for MSA-P diagnosis by ADC test and 67.0% and 80.0% for PD diagnosis by MIBG test. When these tests were restricted to patients with disease duration ≤ 3 years, the sensitivity and specificity were 75.0% and 91.4% for the ADC test (MSA-P diagnosis) and 47.7% and 92.3% for the MIBG test (PD diagnosis). Both tests were useful in differentiating between PD and MSA-P, even in the early stages. In early-stage patients, elevated putaminal ADC was a diagnostic marker for MSA-P. Despite high specificity of the MIBG test, careful neurological history and examinations were required for PD diagnosis because of possible false-negative results.

  2. Operationalizing the Diagnostic Criteria for Mild Cognitive Impairment: The Salience of Objective Measures in Predicting Incident Dementia.

    Science.gov (United States)

    Brodaty, Henry; Aerts, Liesbeth; Crawford, John D; Heffernan, Megan; Kochan, Nicole A; Reppermund, Simone; Kang, Kristan; Maston, Kate; Draper, Brian; Trollor, Julian N; Sachdev, Perminder S

    2017-05-01

    Mild cognitive impairment (MCI) is considered an intermediate stage between normal aging and dementia. It is diagnosed in the presence of subjective cognitive decline and objective cognitive impairment without significant functional impairment, although there are no standard operationalizations for each of these criteria. The objective of this study is to determine which operationalization of the MCI criteria is most accurate at predicting dementia. Six-year longitudinal study, part of the Sydney Memory and Ageing Study. Community-based. 873 community-dwelling dementia-free adults between 70 and 90 years of age. Persons from a non-English speaking background were excluded. Seven different operationalizations for subjective cognitive decline and eight measures of objective cognitive impairment (resulting in 56 different MCI operational algorithms) were applied. The accuracy of each algorithm to predict progression to dementia over 6 years was examined for 618 individuals. Baseline MCI prevalence varied between 0.4% and 30.2% and dementia conversion between 15.9% and 61.9% across different algorithms. The predictive accuracy for progression to dementia was poor. The highest accuracy was achieved based on objective cognitive impairment alone. Inclusion of subjective cognitive decline or mild functional impairment did not improve dementia prediction accuracy. Not MCI, but objective cognitive impairment alone, is the best predictor for progression to dementia in a community sample. Nevertheless, clinical assessment procedures need to be refined to improve the identification of pre-dementia individuals. Copyright © 2016 American Association for Geriatric Psychiatry. Published by Elsevier Inc. All rights reserved.

  3. A new diagnostic accuracy measure and cut-point selection criterion.

    Science.gov (United States)

    Dong, Tuochuan; Attwood, Kristopher; Hutson, Alan; Liu, Song; Tian, Lili

    2017-12-01

    Most diagnostic accuracy measures and criteria for selecting optimal cut-points are only applicable to diseases with binary or three stages. Currently, there exist two diagnostic measures for diseases with general k stages: the hypervolume under the manifold and the generalized Youden index. While hypervolume under the manifold cannot be used for cut-points selection, generalized Youden index is only defined upon correct classification rates. This paper proposes a new measure named maximum absolute determinant for diseases with k stages ([Formula: see text]). This comprehensive new measure utilizes all the available classification information and serves as a cut-points selection criterion as well. Both the geometric and probabilistic interpretations for the new measure are examined. Power and simulation studies are carried out to investigate its performance as a measure of diagnostic accuracy as well as cut-points selection criterion. A real data set from Alzheimer's Disease Neuroimaging Initiative is analyzed using the proposed maximum absolute determinant.

  4. EFFECT OF BASIC SKILLS IN ANY SITUATION TESTS ACCURACY YOUNG PLAYERS

    Directory of Open Access Journals (Sweden)

    Artan R. Kryeziu

    2013-07-01

    Full Text Available The paper aims to establish the impact of basic motor skills in some situational accuracy tests in youth basketball game. In a sample of 60 tested age of 17 year + / - 6 months. We have applied eigjt variables to the tested persons, five of which are predicting, while the other three are criterion tests. Connectivity between motor variables is handled through the correlation of Pearson. The impact of variables predicting in those criteria used in regression analysis. Also significant importance is given to the introduction of connectivity between basic motor skills in several accuracy tests typical for the basketball game situations. Regarding the basic motor skills variables have attained significant coherence, however situational space test throwing the ball in the basket in the same direction and shooting the ball in the basket in the corner 450 degres no coherence with any test has been shown from the space of the appility of basic motor skills. Through regression analysis procedure we’ve reviewed the impact of basic motor skills in some situational accuracy tests. Treat analysis of criterion variables in those predicting we can say that accuracy to situational variables impact junior league players had explosive force. Therefore we can conclude that explosive strength is a quite important factor in the game between young basketball players, with there moving actions the playes can achive their goal of scoring points.

  5. Criteria for selecting electrodes for electrical stimulation: theoretical and practical considerations.

    Science.gov (United States)

    Brummer, S B; Robblee, L S; Hambrecht, F T

    1983-01-01

    Smaller, more charge-intensive electrodes are needed for "safe" stimulation of the nervous system. In this paper we review critical concepts and the state of the art in electrodes. Control of charge density and charge balance are essential to avoid tissue electrolysis. Chemical criteria for "safe" stimulation are reviewed ("safe" is equated with "chemically reversible"). An example of a safe, but generally impractical, charge-injection process is double-layer charging. The limit here is the onset of irreversible faradaic processes. More charge can be safely injected with so-called "capacitor" electrodes, such as porous intermixtures of Ta/Ta2O5. BaTiO3 has excellent dielectric properties and may provide a new generation of capacitor electrodes. Faradaic charge injection is usually partially irreversible since some of the products escape into the solution. With Pt, up to 400 muc/cm2 real area can be absorbed by faradaic reactions of surface-adsorbed species, but a small part is lost due to metal dissolution. The surface of "activated" Ir is covered with a multilayer hydrated oxide. Charge injection occurs via rapid valence change within this oxide. Little or no metal dissolution is observed, and gassing limits are not exceeded even under stringent conditions.

  6. Nuclear Pedigree Criteria of Suspected HNPCC

    Directory of Open Access Journals (Sweden)

    Kładny Józef

    2003-01-01

    Full Text Available Abstract The criteria for the diagnosis of HNPCC established by the ICG-HNPCC are very restrictive as they do not allow for the diagnosis of a large number of "suspected HNPCC" cases - these are families which do no fulfill the strict diagnostic "Amsterdam criteria", but do present with several pedigree and clinical features characteristic for HNPCC. Several series of families suspected of harboring germline mutations in DNA mismatch repair genes have been studied for germline changes in DNA mismatch repair genes and a mutation rate of somewhere between 8-60% was found. Therefore a subgroup of members of the ICG-HNPCC has been working on pedigree/clinical diagnostic criteria for suspected HNPCC. Materials and methods Part I The study was based on two series of colorectal cancer (CRC cases: 1 HNPCC - this group comprised 190 patients affected by CRC from randomly selected families which fulfilled the Amsterdam II criteria registered in Düsseldorf, Germany (102 cases of CRC, Denmark (18 CRCs, Leiden, Holland (23 CRCs and Szczecin, Poland (47 CRCs. 2 Consecutive CRCs - this group comprised 629 (78.0% of 806 individuals with CRC diagnosed in 1991-1997 in the city of Szczecin (ca. 400,000 of inhabitants, Poland. Nuclear pedigrees in both groups were compared for frequency of occurrence of clinical features, that have been shown to be associated with HNPCC. Part II 52 consecutive CRC cases from Szczecin, matching the criteria recognized in part I as appropriate for diagnosis of cases "suspected of HNPCC" were studied for the occurrence of germline hMSH2/hMLH1 constitutional mutations using "exon by exon" sequencing. Results The combination of features - i.e. the occurrence of an HNPCC associated cancer (CRC or cancer of the endometrium, small bowel or urinary tract in a 1st degree relative of a CRC patient; at least one of the patients being diagnosed under age of 50 - appeared to be strongly associated to HNPCC with an OR - 161. Constitutional

  7. A GIS-based extended fuzzy multi-criteria evaluation for landslide susceptibility mapping

    Science.gov (United States)

    Feizizadeh, Bakhtiar; Shadman Roodposhti, Majid; Jankowski, Piotr; Blaschke, Thomas

    2014-01-01

    Landslide susceptibility mapping (LSM) is making increasing use of GIS-based spatial analysis in combination with multi-criteria evaluation (MCE) methods. We have developed a new multi-criteria decision analysis (MCDA) method for LSM and applied it to the Izeh River basin in south-western Iran. Our method is based on fuzzy membership functions (FMFs) derived from GIS analysis. It makes use of nine causal landslide factors identified by local landslide experts. Fuzzy set theory was first integrated with an analytical hierarchy process (AHP) in order to use pairwise comparisons to compare LSM criteria for ranking purposes. FMFs were then applied in order to determine the criteria weights to be used in the development of a landslide susceptibility map. Finally, a landslide inventory database was used to validate the LSM map by comparing it with known landslides within the study area. Results indicated that the integration of fuzzy set theory with AHP produced significantly improved accuracies and a high level of reliability in the resulting landslide susceptibility map. Approximately 53% of known landslides within our study area fell within zones classified as having “very high susceptibility”, with the further 31% falling into zones classified as having “high susceptibility”. PMID:26089577

  8. Target Price Accuracy

    Directory of Open Access Journals (Sweden)

    Alexander G. Kerl

    2011-04-01

    Full Text Available This study analyzes the accuracy of forecasted target prices within analysts’ reports. We compute a measure for target price forecast accuracy that evaluates the ability of analysts to exactly forecast the ex-ante (unknown 12-month stock price. Furthermore, we determine factors that explain this accuracy. Target price accuracy is negatively related to analyst-specific optimism and stock-specific risk (measured by volatility and price-to-book ratio. However, target price accuracy is positively related to the level of detail of each report, company size and the reputation of the investment bank. The potential conflicts of interests between an analyst and a covered company do not bias forecast accuracy.

  9. Accuracy of imaging methods for detection of bone tissue invasion in patients with oral squamous cell carcinoma

    Science.gov (United States)

    Uribe, S; Rojas, LA; Rosas, CF

    2013-01-01

    The objective of this review is to evaluate the diagnostic accuracy of imaging methods for detection of mandibular bone tissue invasion by squamous cell carcinoma (SCC). A systematic review was carried out of studies in MEDLINE, SciELO and ScienceDirect, published between 1960 and 2012, in English, Spanish or German, which compared detection of mandibular bone tissue invasion via different imaging tests against a histopathology reference standard. Sensitivity and specificity data were extracted from each study. The outcome measure was diagnostic accuracy. We found 338 articles, of which 5 fulfilled the inclusion criteria. Tests included were: CT (four articles), MRI (four articles), panoramic radiography (one article), positron emission tomography (PET)/CT (one article) and cone beam CT (CBCT) (one article). The quality of articles was low to moderate and the evidence showed that all tests have a high diagnostic accuracy for detection of mandibular bone tissue invasion by SCC, with sensitivity values of 94% (MRI), 91% (CBCT), 83% (CT) and 55% (panoramic radiography), and specificity values of 100% (CT, MRI, CBCT), 97% (PET/CT) and 91.7% (panoramic radiography). Available evidence is scarce and of only low to moderate quality. However, it is consistently shown that current imaging methods give a moderate to high diagnostic accuracy for the detection of mandibular bone tissue invasion by SCC. Recommendations are given for improving the quality of future reports, in particular provision of a detailed description of the patients' conditions, the imaging instrument and both imaging and histopathological invasion criteria. PMID:23420854

  10. Terminology and reporting criteria for radiofrequency ablation of tumors in the scientific literature: Systematic review of compliance with reporting standards

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Tae Wook; Rhim, Hyun Chul; Lee, Min Woo; Kim, Young Sun; Choi, Dongil; Lim, Hyo Keun [Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2014-02-15

    To perform a systematic review of compliance with standardized terminology and reporting criteria for radiofrequency (RF) tumor ablation, proposed by the International Working Group on Image-Guided Tumor Ablation in 2003, in the published reports. Literature search in the PubMed database was performed using index keywords, PubMed limit system, and eligibility criteria. The entire content of each article was reviewed to assess the terminology used for procedure terms, imaging findings, therapeutic efficacy, follow-up, and complications. Accuracy of the terminology and the use of alternative terms instead of standard terminology were analyzed. In addition, disparities in accuracy of terminology in articles according to the medical specialty and the type of radiology journal were evaluated. Among the articles (n = 308) included in this study, the accuracy of the terms 'procedure or session', 'treatment', 'index tumor', 'ablation zone', 'technical success', 'primary technique effectiveness rate', 'secondary technique effectiveness rate', 'local tumor progression', 'major complication', and 'minor complication' was 97% (298/307), 97% (291/300), 8% (25/307), 65% (103/159), 55% (52/94), 33% (42/129), 94% (17/18), 45% (88/195), 99% (79/80), and 100% (77/77), respectively. The overall accuracy of each term showed a tendency to improve over the years. The most commonly used alternative terms for 'technical success' and 'local tumor progression' were 'complete ablation' and 'local (tumor) recurrence', respectively. The accuracy of terminology in articles published in radiology journals was significantly greater than that of terminology in articles published in non-radiology journals, especially in Radiology and The Journal of Vascular and Interventional Radiology. The proposal for standardization of terminology and reporting criteria for

  11. The implementation of modern digital technology in x-ray medical diagnosis in Republic of Moldova - a stringent necessity

    International Nuclear Information System (INIS)

    Rosca, Andrei

    2011-01-01

    The study includes analyses of current technical state of radiodiagnostic equipment from the Public Medico-Sanitary Institution of Ministry of Health of Republic of Moldova (IMSP MS RM). The traditional radiodiagnostic apparatuses were morally and physically outrun at 96,6% (in regional MSPI - 93,5%), inclusive the dental one - 92,0% (in raional MSPI - 97,2%), X-Ray exam -100%, mobile - 84,1% etc. The exploitation of the traditional radiodiagnostic apparatuses with high degree of physical and moral wear essentially diminished the quality of profile investigation, creates premises for diagnostic error perpetrating, increase the collective ionizing irradiation of population etc. In recent years the subvention of MSPI HM RM with digital radiodiagnostic equipment was started. This process is very hard unfold because of grave socio-economic crises in Republic of Moldova. Despite these obstacles the subvention of MSPI HM RM with digital equipment represents a stringent necessity and a time request.

  12. The rapidly evolving centromere-specific histone has stringent functional requirements in Arabidopsis thaliana.

    Science.gov (United States)

    Ravi, Maruthachalam; Kwong, Pak N; Menorca, Ron M G; Valencia, Joel T; Ramahi, Joseph S; Stewart, Jodi L; Tran, Robert K; Sundaresan, Venkatesan; Comai, Luca; Chan, Simon W-L

    2010-10-01

    Centromeres control chromosome inheritance in eukaryotes, yet their DNA structure and primary sequence are hypervariable. Most animals and plants have megabases of tandem repeats at their centromeres, unlike yeast with unique centromere sequences. Centromere function requires the centromere-specific histone CENH3 (CENP-A in human), which replaces histone H3 in centromeric nucleosomes. CENH3 evolves rapidly, particularly in its N-terminal tail domain. A portion of the CENH3 histone-fold domain, the CENP-A targeting domain (CATD), has been previously shown to confer kinetochore localization and centromere function when swapped into human H3. Furthermore, CENP-A in human cells can be functionally replaced by CENH3 from distantly related organisms including Saccharomyces cerevisiae. We have used cenh3-1 (a null mutant in Arabidopsis thaliana) to replace endogenous CENH3 with GFP-tagged variants. A H3.3 tail domain-CENH3 histone-fold domain chimera rescued viability of cenh3-1, but CENH3's lacking a tail domain were nonfunctional. In contrast to human results, H3 containing the A. thaliana CATD cannot complement cenh3-1. GFP-CENH3 from the sister species A. arenosa functionally replaces A. thaliana CENH3. GFP-CENH3 from the close relative Brassica rapa was targeted to centromeres, but did not complement cenh3-1, indicating that kinetochore localization and centromere function can be uncoupled. We conclude that CENH3 function in A. thaliana, an organism with large tandem repeat centromeres, has stringent requirements for functional complementation in mitosis.

  13. [Evaluation of accuracy of virtual occlusal definition in Angle class I molar relationship].

    Science.gov (United States)

    Wu, L; Liu, X J; Li, Z L; Wang, X

    2018-02-18

    To evaluate the accuracy of virtual occlusal definition in non-Angle class I molar relationship, and to evaluate the clinical feasibility. Twenty pairs of models of orthognathic patients were included in this study. The inclusion criteria were: (1) finished with pre-surgical orthodontic treatment and (2) stable final occlusion. The exclusion criteria were: (1) existence of distorted teeth, (2) needs for segmentation, (3) defect of dentition except for orthodontic extraction ones, and (4) existence of tooth space. The tooth-extracted test group included 10 models with two premolars extracted during preoperative orthodontic treatment. Their molar relationships were not Angle class I relationship. The non-tooth-extracted test group included another 10 models without teeth extracted, therefore their molar relationships were Angle class I. To define the final occlusion in virtual environment, two steps were included: (1) The morphology data of upper and lower dentition were digitalized by surface scanner (Smart Optics/Activity 102; Model-Tray GmbH, Hamburg, Germany); (2) the virtual relationships were defined using 3Shape software. The control standard of final occlusion was manually defined using gypsum models and then digitalized by surface scanner. The final occlusion of test group and control standard were overlapped according to lower dentition morphology. Errors were evaluated by calculating the distance between the corresponding reference points of testing group and control standard locations. The overall errors for upper dentition between test group and control standard location were (0.51±0.18) mm in non-tooth-extracted test group and (0.60±0.36) mm in tooth-extracted test group. The errors were significantly different between these two test groups (P0.05); and the accuracy of non-tooth-extracted group was significantly smaller than 1 mm (Pdefinition of none class I molar relationship is higher than that of class I relationship, with an accuracy of 1 mm

  14. Design criteria for small coded aperture masks in gamma-ray astronomy

    International Nuclear Information System (INIS)

    Sembay, S.; Gehrels, N.

    1990-01-01

    Most theoretical work on coded aperture masks in X-ray and low-energy γ-ray astronomy has concentrated on masks with large numbers of elements. For γ-ray spectrometers in the MeV range, the detector plane usually has only a few discrete elements, so that masks with small numbers of elements are called for. For this case it is feasible to analyse by computer all the possible mask patterns of given dimension to find the ones that best satisfy the desired performance criteria. In this paper we develop a particular set of performance criteria for comparing the flux sensitivities, source positioning accuracies and transparencies of different mask patterns. We then present the results of such a computer analysis for masks up to dimension 5x5 unit cell and conclude that there is a great deal of flexibility in one's choice of mask pattern for each dimension. (orig.)

  15. Diagnostic Criteria on 18F-FDG PET/CT for Differentiating Benign from Malignant Focal Hypermetabolic Lesions of Parotid Gland

    International Nuclear Information System (INIS)

    Park, Soo Bin; Choi, Joon Young; Lee, Eun Jeong; Yoo, Jang; Cheon, Miju; Cho, Suk Kyong; Choe, Yearn Seong; Lee, Kyung-Han; Kim, Byung-Tae

    2012-01-01

    We investigated PET/CT diagnostic criteria for differentiating benign from malignant parotid lesions with focal 18 F-FDG uptake. The subjects of the study were 272 patients who exhibited focal 18 F-FDG uptake of the parotid gland. Sixty-eight pathologically confirmed parotid lesions from 67 patients were included. The maximum SUV (SUVmax), uptake patterns (homogeneous vs. heterogeneous), size measured by CT, maximum Housfield units (HUmax) and margins on CT (well vs. ill defined) of each parotid lesion on PET/CT images were compared with final diagnoses. Thirty- two parotid lesions were histologically proven to be malignant. There were significant differences in uptake patterns (cancer incidence, heterogeneous:homogeneous=79.2%:29.5%, p<0.0001) and margins on CT (cancer incidence, ill:well defined=84.4%:13.3%, p<0.0001) between benign and malignant lesions. The cancer risks of parotid lesions were 89.5% with heterogeneous uptake and ill-defined margins, 70.6% with heterogeneous uptake or ill-defined margins (no overlap in subjects) and 9.3% with homogeneous uptake and well-defined margins (p<0.0001). When any lesion with heterogeneous uptake or ill-defined margins was regarded as malignant, the sensitivity, positive predictive value, negative predictive value and accuracy were 90.6% (29/32) and 85.6% (58/68), respectively. For predicting malignancy, combined PET/CT criteria showed better sensitivity, NPV and accuracy than PET-only criteria, and had a tendency to have more accurate results than CT-only criteria, and had a tendency to have more accurate results than CT-only criteria. There were no significant differences in SUVmax, size or HUmax between benign and malignant lesions. Uptake patterns and margins on CT are useful PET/CT diagnostic criteria for differentiating benign from malignant lesions

  16. Metabolic syndrome criteria as predictors of insulin resistance, inflammation and mortality in chronic hemodialysis patients.

    Science.gov (United States)

    Vogt, Barbara Perez; Souza, Priscilla L; Minicucci, Marcos Ferreira; Martin, Luis Cuadrado; Barretti, Pasqual; Caramori, Jacqueline Teixeira

    2014-10-01

    Abstract Background: Chronic kidney disease (CKD) and metabolic syndrome are characterized by overlapping disorders, including glucose intolerance, hypertension, dyslipidemia, and, in some cases, obesity. However, there are no specific criteria for the diagnosis of metabolic syndrome in CKD. Metabolic syndrome can also be associated with increased risk of mortality. Some traditional risk factors may protect dialysis patients from mortality, known as "reverse epidemiology." Metabolic syndrome might undergo reverse epidemiology. The objectives were to detect differences in frequency and metabolic characteristics associated with three sets of diagnostic criteria for metabolic syndrome, to evaluate the accuracy of insulin resistance (IR) and inflammation to identify patients with metabolic syndrome, and to investigate the effects of metabolic syndrome by three sets of diagnostic criteria on mortality in chronic hemodialysis patients. An observational study was conducted. Diagnostic criteria for metabolic syndrome proposed by National Cholesterol Education Program Adult Treatment Panel III (NCEP ATP III), International Diabetes Federation (IDF), and Harmonizing the Metabolic Syndrome (HMetS) statement were applied to 98 hemodialysis patients. The prevalence of metabolic syndrome was 51%, 66.3%, and 75.3% according to NCEP ATP III, IDF, and HMetS criteria, respectively. Diagnosis of metabolic syndrome by HMetS was simultaneously capable of revealing both inflammation and IR, whereas NCEP ATP III and IDF criteria were only able to identify IR. Mortality risk increased in the presence of metabolic syndrome regardless of the criteria used. The prevalence of metabolic syndrome in hemodialysis varies according to the diagnostic criteria used. IR and inflammation predict metabolic syndrome only when diagnosed by HMetS criteria. HMetS was the diagnostic criteria that can predict the highest risk of mortality.

  17. Approximating a DSM-5 Diagnosis of PTSD Using DSM-IV Criteria

    Science.gov (United States)

    Rosellini, Anthony J.; Stein, Murray B.; Colpe, Lisa J.; Heeringa, Steven G.; Petukhova, Maria V.; Sampson, Nancy A.; Schoenbaum, Michael; Ursano, Robert J.; Kessler, Ronald C.

    2015-01-01

    Background Diagnostic criteria for DSM-5 posttraumatic stress disorder (PTSD) are in many ways similar to DSM-IV criteria, raising the possibility that it might be possible to closely approximate DSM-5 diagnoses using DSM-IV symptoms. If so, the resulting transformation rules could be used to pool research data based on the two criteria sets. Methods The Pre-Post Deployment Study (PPDS) of the Army Study to Assess Risk and Resilience in Servicemembers (Army STARRS) administered a blended 30-day DSM-IV and DSM-5 PTSD symptom assessment based on the civilian PTSD Checklist for DSM-IV (PCL-C) and the PTSD Checklist for DSM-5 (PCL-5). This assessment was completed by 9,193 soldiers from three US Army Brigade Combat Teams approximately three months after returning from Afghanistan. PCL-C items were used to operationalize conservative and broad approximations of DSM-5 PTSD diagnoses. The operating characteristics of these approximations were examined compared to diagnoses based on actual DSM-5 criteria. Results The estimated 30-day prevalence of DSM-5 PTSD based on conservative (4.3%) and broad (4.7%) approximations of DSM-5 criteria using DSM-IV symptom assessments were similar to estimates based on actual DSM-5 criteria (4.6%). Both approximations had excellent sensitivity (92.6-95.5%), specificity (99.6-99.9%), total classification accuracy (99.4-99.6%), and area under the receiver operating characteristic curve (0.96-0.98). Conclusions DSM-IV symptoms can be used to approximate DSM-5 diagnoses of PTSD among recently-deployed soldiers, making it possible to recode symptom-level data from earlier DSM-IV studies to draw inferences about DSM-5 PTSD. However, replication is needed in broader trauma-exposed samples to evaluate the external validity of this finding. PMID:25845710

  18. Regulatory and extra-regulatory testing to demonstrate radioactive material packaging safety

    International Nuclear Information System (INIS)

    Ammerman, D.J.

    1997-01-01

    Packages for the transportation of radioactive material must meet performance criteria to assure safety and environmental protection. The stringency of the performance criteria is based on the degree of hazard of the material being transported. Type B packages are used for transporting large quantities of radioisotopes (in terms of A 2 quantities). These packages have the most stringent performance criteria. Material with less than an A 2 quantity are transported in Type A packages. These packages have less stringent performance criteria. Transportation of LSA and SCO materials must be in open-quotes strong-tightclose quotes packages. The performance requirements for the latter packages are even less stringent. All of these package types provide a high level of safety for the material being transported. In this paper, regulatory tests that are used to demonstrate this safety will be described. The responses of various packages to these tests will be shown. In addition, the response of packages to extra-regulatory tests will be discussed. The results of these tests will be used to demonstrate the high level of safety provided to workers, the public, and the environment by packages used for the transportation of radioactive material

  19. Diagnostic accuracy of slit skin smears in leprosy

    International Nuclear Information System (INIS)

    Naveed, T.; Shaikh, Z.

    2015-01-01

    To determine the diagnostic accuracy of slit skin smears in clinically suspected patients of leprosy using histopathology as gold standard. Study Design: Validation study Place and Duration of Study: Study was carried out at Rawalpindi Leprosy Hospital, Dermatology Department Military Hospital (MH) and Armed Forces Institute of Pathology (AFIP), Rawalpindi from 18th August 2012 to 18 Feb 2013. Methods: Appropriate technical and ethical approval for the study and patient consent were obtained. All suspected patients of leprosy of any age and either gender having typical hypo-aesthetic or anesthetic, erythematous or hypo-pigmented scaly skin lesions on any part of body were included in this study. All patients who have already received treatment for leprosy, patients with pure neural leprosy, patient not giving their consent for skin biopsy and patients with lepra reactions were excluded from this study. Forty eight patients fulfilling the inclusion criteria were included in the study. Sample size had been calculated by using WHO sample size calculator taking confidence level 95%, absolute precision required 14% and anticipated population proportion 40%. Non-probability consecutive sampling technique was used to collect sample. Results: The results of the study revealed that out of 48 clinically suspected patients of leprosy skin biopsy confirmed the diagnosis in 34 patients (70.8%) and the slit skin smear had diagnostic accuracy of 68.75% with sensitivity 55.8% and specificity and positive predictive value of 100%. Conclusion: Study suggested that although slit skin smears are rapid and inexpensive method of diagnosis but their diagnostic accuracy is low. (author)

  20. Sex-specific criteria for interpretation of thallium-201 myocardial uptake and washout studies

    International Nuclear Information System (INIS)

    Rabinovitch, M.; Suissa, S.; Elstein, J.

    1986-01-01

    A study was undertaken to determine the effect of gender on criteria for the quantitative analysis of exercise-redistribution 201 Tl myocardial scintigraphy. The studies of 26 normal females and 23 normal males were subjected to bilinear interpolative background subtraction and horizontal profile analysis. Significant sexual differences were found in both regional uptake ratios and washout rates. These differences primarily reflected a proportionately decreased anterior and upper septal uptake in females, and faster washout in females. Faster myocardial 201 Tl washout rates in females could not be clearly ascribed to either a physiological or artifactual explanation. It is concluded that since important differences exist between males and females in the detected pattern of 201 Tl myocardial uptake and washout, sex-specific criteria may enhance the predictive accuracy of exercise-redistribution 201 Tl myocardial scintigraphy

  1. Specification of test criteria and probabilistic approach: the case of plutonium air transport

    International Nuclear Information System (INIS)

    Hubert, P.; Pages, P.; Ringot, C.; Tomachewsky, E.

    1989-03-01

    The safety of international transportation relies on compliance with IAEA regulations which specify a serie of test which the package is supposed to withstand. For Plutonium air transport some national regulations are more stringent than the IAEA one, namely the US one. For example the drop test is to be performed at 129 m.s -1 instead of 13.4 m.s -1 . The development of international Plutonium exchanges has raised the question of the adequacy of both those standards. The purpose of this paper is to show how a probabilistic approach helps in assessing the efficiency of a move towards more stringent tests

  2. Combining the IADPSG criteria with the WHO diagnostic criteria for ...

    African Journals Online (AJOL)

    Macrosomia or at least one adverse outcome were more likely in GDM patients who met the diagnostic criteria by both the IADPSG and WHO criteria (P = 0.001). Conclusion: A diagnosis of GDM that meets both the WHO and IADPSG criteria provides stronger prediction for adverse pregnancy outcome than a diagnosis that ...

  3. Are Dutch residents ready for a more stringent policy to enhance the energy performance of their homes?

    International Nuclear Information System (INIS)

    Middelkoop, Manon van; Vringer, Kees; Visser, Hans

    2017-01-01

    Investments in the energy performance of houses offer good prospects for reducing energy consumption and CO_2 emissions. However, people are not easily convinced of the need to take measures to improve the energy performance of their houses, even when financial benefits outweigh the costs. This article analyses the factors that influence the decision for improving the energy performance of existing homes, including policy instruments. Subsequently, the article provides policy suggestions on how to stimulate energy performance improvements. Both owners and tenants (50–70%) support government policy on energy performance improvements to existing homes. Nevertheless, people also have strong feelings of autonomy regarding their homes. Our results underline the importance of well-informed and competent decision-makers. Introducing the use of Energy Performance Certificates (EPCs) into the tax system for energy and residential buildings might therefore be an effective way to increase the interest of owners in the EPC, improve the use and effect of this informative instrument, and make the first step towards bridging the tension between autonomy and more stringent instruments.

  4. Physiologically-based, predictive analytics using the heart-rate-to-Systolic-Ratio significantly improves the timeliness and accuracy of sepsis prediction compared to SIRS.

    Science.gov (United States)

    Danner, Omar K; Hendren, Sandra; Santiago, Ethel; Nye, Brittany; Abraham, Prasad

    2017-04-01

    Enhancing the efficiency of diagnosis and treatment of severe sepsis by using physiologically-based, predictive analytical strategies has not been fully explored. We hypothesize assessment of heart-rate-to-systolic-ratio significantly increases the timeliness and accuracy of sepsis prediction after emergency department (ED) presentation. We evaluated the records of 53,313 ED patients from a large, urban teaching hospital between January and June 2015. The HR-to-systolic ratio was compared to SIRS criteria for sepsis prediction. There were 884 patients with discharge diagnoses of sepsis, severe sepsis, and/or septic shock. Variations in three presenting variables, heart rate, systolic BP and temperature were determined to be primary early predictors of sepsis with a 74% (654/884) accuracy compared to 34% (304/884) using SIRS criteria (p < 0.0001)in confirmed septic patients. Physiologically-based predictive analytics improved the accuracy and expediency of sepsis identification via detection of variations in HR-to-systolic ratio. This approach may lead to earlier sepsis workup and life-saving interventions. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Evaluation of the accuracy of estimated baseline serum creatinine for acute kidney injury diagnosis.

    Science.gov (United States)

    Hatakeyama, Yutaka; Horino, Taro; Nagata, Keitaro; Kataoka, Hiromi; Matsumoto, Tatsuki; Terada, Yoshio; Okuhara, Yoshiyasu

    2018-04-01

    Modern epidemiologic studies of acute kidney injury (AKI) have been facilitated by the increasing availability of electronic medical records. However, pre-morbid reference serum creatinine (SCr) data are often unavailable in such records. Investigators substitute estimated baseline SCr with the eGFR 75 approach, instead of using actually measured baseline SCr. Here, we evaluated the accuracy of estimated baseline SCr for AKI diagnosis in the Japanese population. Inpatients and outpatients aged 18-80 years were retrospectively enrolled. AKI was diagnosed according to the Kidney Disease Improving Global Outcomes (KDIGO) criteria, using SCr levels. The non-AKI and AKI groups were selected using the following criteria: increase 1.5 times greater than baseline SCr ("baseline SCr") or increase 0.3 mg/dL greater than baseline SCr in 48 h ("increase in 48 h"). AKI accuracy defined by the estimated reference SCr, the average SCr value of the non-AKI population (eb-GFR-A approach), or the back-calculated SCr from fixed eGFR = 75 mL/min/1.73 m 2 (eGFR 75 approach, or, eb-GFR-B approach in this study), was evaluated. We analyzed data from 131,358 Japanese patients. The number of patients with reference baseline SCr in the non-AKI and AKI patients were 29,834 and 8952, respectively. For AKI patients diagnosed using "baseline SCr", the AKI diagnostic accuracy rates as defined by eb-GFR-A and eb-GFR-B were 63.5 and 57.7%, respectively, while in AKI diagnosed using "increase in 48 h", the AKI diagnostic accuracy rates as defined by eb-GFR-A and eb-GFR-B were 78.7 and 75.1%, respectively. In non-AKI patients, false-positive rates of AKI misdiagnosed via eb-GFR-A and eb-GFR-B were 7.4 and 6.8%, respectively. AKI diagnosis using the average SCr value of the general population may yield more accurate results than diagnosis using the eGFR 75 approach when the reference SCr is unavailable.

  6. Molecular Isotopic Distribution Analysis (MIDAs) with adjustable mass accuracy.

    Science.gov (United States)

    Alves, Gelio; Ogurtsov, Aleksey Y; Yu, Yi-Kuo

    2014-01-01

    In this paper, we present Molecular Isotopic Distribution Analysis (MIDAs), a new software tool designed to compute molecular isotopic distributions with adjustable accuracies. MIDAs offers two algorithms, one polynomial-based and one Fourier-transform-based, both of which compute molecular isotopic distributions accurately and efficiently. The polynomial-based algorithm contains few novel aspects, whereas the Fourier-transform-based algorithm consists mainly of improvements to other existing Fourier-transform-based algorithms. We have benchmarked the performance of the two algorithms implemented in MIDAs with that of eight software packages (BRAIN, Emass, Mercury, Mercury5, NeutronCluster, Qmass, JFC, IC) using a consensus set of benchmark molecules. Under the proposed evaluation criteria, MIDAs's algorithms, JFC, and Emass compute with comparable accuracy the coarse-grained (low-resolution) isotopic distributions and are more accurate than the other software packages. For fine-grained isotopic distributions, we compared IC, MIDAs's polynomial algorithm, and MIDAs's Fourier transform algorithm. Among the three, IC and MIDAs's polynomial algorithm compute isotopic distributions that better resemble their corresponding exact fine-grained (high-resolution) isotopic distributions. MIDAs can be accessed freely through a user-friendly web-interface at http://www.ncbi.nlm.nih.gov/CBBresearch/Yu/midas/index.html.

  7. NWTS program criteria for mined geologic disposal of nuclear wasite: site performance criteria

    International Nuclear Information System (INIS)

    1981-02-01

    This report states ten criteria governing the suitability of sites for mined geologic disposal of high-level radioactive waste. The Department of Energy will use these criteria in its search for sites and will reevaluate their use when the Nuclear Regulatory Commission issues radioactive waste repository rules. These criteria encompass site geometry, geohydrology, geochemistry, geologic characteristics, tectonic environment, human intrusion, surface characteristics, environment, and potential socioeconomic impacts. The contents of this document include background discussion, site performance criteria, and appendices. The background section describes the waste disposal system, the application of the site criteria, and applicable criteria from NWTS-33(1) - Program Objectives, Functional Requirements and System Performance Criteria. Appendix A, entitled Comparison with Other Siting Criteria compares the NWTS criteria with those recommended by other agencies. Appendix B contains DOE responses to public comments received on the January 1980 draft of this document. Appendix C is a glossary

  8. Accuracy of the ECG for differential diagnosis between hypertrophic cardiomyopathy and athlete's heart: comparison between the European Society of Cardiology (2010) and International (2017) criteria.

    Science.gov (United States)

    Zorzi, Alessandro; Calore, Chiara; Vio, Riccardo; Pelliccia, Antonio; Corrado, Domenico

    2018-05-01

    Interpretation of the athlete's ECG is based on differentiation between benign ECG changes and potentially pathological abnormalities. The aim of the study was to compare the 2010 European Society of Cardiology (ESC) and the 2017 International criteria for differential diagnosis between hypertrophic cardiomyopathy (HCM) and athlete's heart. The study populations included 200 patients with HCM and 563 athletes grouped as follows: 'group 1', including normal ECG and isolated increase of QRS voltages, which are considered non-pathologic according to ESC and International criteria; 'group 2', including left atrial enlargement or left axis deviation in isolation and Q-waves with an amplitude ≥4 mm but <25% of the ensuing R-wave and a duration <0.04 s which are considered pathologic according to the ESC but not according to the International criteria; and 'group 3', including abnormalities which are considered pathologic according to ESC and International criteria. Overall, the 2010 ESC criteria showed a sensitivity of 95.5% and a specificity of 86.9%. Considering group 2 ECG changes as normal according to the International criteria led to a statistically significant (p<0.001) increase of specificity to 95.9%, associated with a non-significant (p=0.47) reduction of sensitivity to 93%. Among patients with HCM, there was a significant increase of maximal left ventricular wall thickness from group 1 to 3 (p=0.02). The use of 2017 International criteria is associated with a substantial increase in specificity and a marginal decrease in sensitivity for differential diagnosis between HCM and athlete's heart. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Diagnostic accuracy of segmental enhancement inversion for diagnosis of renal oncocytoma at biphasic contrast enhanced CT: systematic review

    International Nuclear Information System (INIS)

    Schieda, Nicola; McInnes, Matthew D.F.; Cao, Lilly

    2014-01-01

    To use systematic review to evaluate the diagnostic accuracy of segmental enhancement inversion (SEI) at contrast-enhanced biphasic multi-detector computed tomography (MDCT) for the diagnosis of renal oncocytoma. Several electronic databases were searched through October 2013. Two reviewers independently selected studies that met the inclusion criteria and extracted data. Study quality was assessed with the QUADAS-2 tool. The primary 2 x 2 data were investigated with forest plot and ROC plot of sensitivity and specificity. Four studies met the inclusion criteria (307 patients). Considerable heterogeneity between studies precluded meta-analysis. Two studies from the same group of investigators demonstrated reasonable diagnostic accuracy (sensitivity 59-80 % and specificity 87-99 %), while two others did not (sensitivity 0-6 %, specificity 93-100 %). Possible reasons for this include timing of biphasic MDCT and methods of interpretation but not size of lesion. SEI is a specific imaging finding of renal oncocytoma with highly variable sensitivity. This substantial heterogeneity across studies and between institutions suggests that further validation of this imaging finding is necessary prior to application in clinical practice. (orig.)

  10. Diagnostic accuracy of segmental enhancement inversion for diagnosis of renal oncocytoma at biphasic contrast enhanced CT: systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Schieda, Nicola; McInnes, Matthew D.F.; Cao, Lilly [Ottawa Hospital Research Institute, Department of Medical Imaging, Ottawa, ON (Canada)

    2014-06-15

    To use systematic review to evaluate the diagnostic accuracy of segmental enhancement inversion (SEI) at contrast-enhanced biphasic multi-detector computed tomography (MDCT) for the diagnosis of renal oncocytoma. Several electronic databases were searched through October 2013. Two reviewers independently selected studies that met the inclusion criteria and extracted data. Study quality was assessed with the QUADAS-2 tool. The primary 2 x 2 data were investigated with forest plot and ROC plot of sensitivity and specificity. Four studies met the inclusion criteria (307 patients). Considerable heterogeneity between studies precluded meta-analysis. Two studies from the same group of investigators demonstrated reasonable diagnostic accuracy (sensitivity 59-80 % and specificity 87-99 %), while two others did not (sensitivity 0-6 %, specificity 93-100 %). Possible reasons for this include timing of biphasic MDCT and methods of interpretation but not size of lesion. SEI is a specific imaging finding of renal oncocytoma with highly variable sensitivity. This substantial heterogeneity across studies and between institutions suggests that further validation of this imaging finding is necessary prior to application in clinical practice. (orig.)

  11. A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry

    International Nuclear Information System (INIS)

    MacDougall, N.D.; Pitchford, W.G.; Smith, M.A.

    2002-01-01

    The purpose of this work is to undertake a critical appraisal of the evidence in the published literature concerning the basic parameters of accuracy and precision associated with the use of Fricke and polymer gels (in conjunction with MR imaging) as radiation dosimeters in photon radiotherapy, condensing and analysing the body of published information (to the end of April 2002). A systematic review was undertaken addressing specific issues of precision and accuracy asking defined questions of the published literature. Accuracy and precision in relation to gel dosimetry were defined. Information was obtained from published, peer-reviewed journals. A defined search strategy utilizing MeSH headings and keywords, with extensive use of cross-referencing, identified 115 references dealing with gel dosimetry. Exclusion criteria were used to select only data from publications which would give unequivocal evidence. For accuracy, results had to be compared with an ionization chamber as gold standard and all gel samples had to be manufactured in the same batch. For precision, in addition to gels being from the same batch, samples must all have been irradiated at the same time and scanned simultaneously (or within a short time frame). Many results were found demonstrating 'dose mapping' examples using gels. However, there were very few publications containing firm evidence of precision and accuracy. There was no evidence which fulfilled our criteria about accuracy or precision using Fricke gels. For polymer gels only one paper was found for accuracy (4% (Low et al 1999 Med. Phys. 26 1542-51)) and precision (1.7% (Baldock et al 1998 Phys. Med. Biol. 43 695-702)); however, both were carried out at only one dose level. If the exclusion criteria were relaxed to include accuracy results comparing gel to a non gold standard dosimeter (e.g. TLD), results give a median accuracy of 10% (range 8-23.5%) for polymer gel (Cosgrove et al 2000 Phys. Med. Biol. 45 1195-210, De Deene et al

  12. Diagnostic accuracy research in glaucoma is still incompletely reported: An application of Standards for Reporting of Diagnostic Accuracy Studies (STARD 2015.

    Directory of Open Access Journals (Sweden)

    Manuele Michelessi

    Full Text Available Research has shown a modest adherence of diagnostic test accuracy (DTA studies in glaucoma to the Standards for Reporting of Diagnostic Accuracy Studies (STARD. We have applied the updated 30-item STARD 2015 checklist to a set of studies included in a Cochrane DTA systematic review of imaging tools for diagnosing manifest glaucoma.Three pairs of reviewers, including one senior reviewer who assessed all studies, independently checked the adherence of each study to STARD 2015. Adherence was analyzed on an individual-item basis. Logistic regression was used to evaluate the effect of publication year and impact factor on adherence.We included 106 DTA studies, published between 2003-2014 in journals with a median impact factor of 2.6. Overall adherence was 54.1% for 3,286 individual rating across 31 items, with a mean of 16.8 (SD: 3.1; range 8-23 items per study. Large variability in adherence to reporting standards was detected across individual STARD 2015 items, ranging from 0 to 100%. Nine items (1: identification as diagnostic accuracy study in title/abstract; 6: eligibility criteria; 10: index test (a and reference standard (b definition; 12: cut-off definitions for index test (a and reference standard (b; 14: estimation of diagnostic accuracy measures; 21a: severity spectrum of diseased; 23: cross-tabulation of the index and reference standard results were adequately reported in more than 90% of the studies. Conversely, 10 items (3: scientific and clinical background of the index test; 11: rationale for the reference standard; 13b: blinding of index test results; 17: analyses of variability; 18; sample size calculation; 19: study flow diagram; 20: baseline characteristics of participants; 28: registration number and registry; 29: availability of study protocol; 30: sources of funding were adequately reported in less than 30% of the studies. Only four items showed a statistically significant improvement over time: missing data (16, baseline

  13. Diagnostic Criteria, Classification and Treatment Goals in Multiple Sclerosis: The Chronicles of Time and Space.

    Science.gov (United States)

    Ntranos, Achilles; Lublin, Fred

    2016-10-01

    Multiple sclerosis (MS) is one of the most diverse human diseases. Since its first description by Charcot in the nineteenth century, the diagnostic criteria, clinical course classification, and treatment goals for MS have been constantly revised and updated to improve diagnostic accuracy, physician communication, and clinical trial design. These changes have improved the clinical outcomes and quality of life for patients with the disease. Recent technological and research breakthroughs will almost certainly further change how we diagnose, classify, and treat MS in the future. In this review, we summarize the key events in the history of MS, explain the reasoning behind the current criteria for MS diagnosis, classification, and treatment, and provide suggestions for further improvements that will keep enhancing the clinical practice of MS.

  14. Plutonium storage criteria

    Energy Technology Data Exchange (ETDEWEB)

    Chung, D. [Scientech, Inc., Germantown, MD (United States); Ascanio, X. [Dept. of Energy, Germantown, MD (United States)

    1996-05-01

    The Department of Energy has issued a technical standard for long-term (>50 years) storage and will soon issue a criteria document for interim (<20 years) storage of plutonium materials. The long-term technical standard, {open_quotes}Criteria for Safe Storage of Plutonium Metals and Oxides,{close_quotes} addresses the requirements for storing metals and oxides with greater than 50 wt % plutonium. It calls for a standardized package that meets both off-site transportation requirements, as well as remote handling requirements from future storage facilities. The interim criteria document, {open_quotes}Criteria for Interim Safe Storage of Plutonium-Bearing Solid Materials{close_quotes}, addresses requirements for storing materials with less than 50 wt% plutonium. The interim criteria document assumes the materials will be stored on existing sites, and existing facilities and equipment will be used for repackaging to improve the margin of safety.

  15. Do MCI criteria in drug trials accurately identify subjects with predementia Alzheimer's disease?

    Science.gov (United States)

    Visser, P; Scheltens, P; Verhey, F

    2005-01-01

    Background: Drugs effective in Alzheimer-type dementia have been tested in subjects with mild cognitive impairment (MCI) because these are supposed to have Alzheimer's disease in the predementia stage. Objectives: To investigate whether MCI criteria used in these drug trials can accurately diagnose subjects with predementia Alzheimer's disease. Methods: MCI criteria of the Gal-Int 11 study, InDDEx study, ADCS memory impairment study, ampakine CX 516 study, piracetam study, and Merck rofecoxib study were applied retrospectively in a cohort of 150 non-demented subjects from a memory clinic. Forty two had progressed to Alzheimer type dementia during a five year follow up period and were considered to have predementia Alzheimer's disease at baseline. Outcome measures were the odds ratio, sensitivity, specificity, and positive and negative predictive value. Results: The odds ratio of the MCI criteria for predementia Alzheimer's disease varied between 0.84 and 11. Sensitivity varied between 0.46 and 0.83 and positive predictive value between 0.43 and 0.76. None of the criteria combined a high sensitivity with a high positive predictive value. Exclusion criteria for depression led to an increase in positive predictive value and specificity at the cost of sensitivity. In subjects older than 65 years the positive predictive value was higher than in younger subjects. Conclusions: The diagnostic accuracy of MCI criteria used in trials for predementia Alzheimer's disease is low to moderate. Their use may lead to inclusion of many patients who do not have predementia Alzheimer's disease or to exclusion of many who do. Subjects with moderately severe depression should not be excluded from trials in order not to reduce the sensitivity. PMID:16170074

  16. Elimination of pain improves specificity of clinical diagnostic criteria for adult chronic rhinosinusitis.

    Science.gov (United States)

    Hirsch, Scott D; Reiter, Evan R; DiNardo, Laurence J; Wan, Wen; Schuman, Theodore A

    2017-05-01

    Determine whether the elimination of pain improves accuracy of clinical diagnostic criteria for adult chronic rhinosinusitis. Retrospective cohort study. History, symptoms, nasal endoscopy, and computed tomography (CT) results were analyzed for 1,186 adults referred to an academic otolaryngology clinic with presumptive diagnosis of chronic rhinosinusitis. Clinical diagnosis was rendered using the 1997 Rhinosinusitis Taskforce (RSTF) Guidelines and a modified version eliminating facial pain, ear pain, dental pain, and headache. Four hundred seventy-nine subjects (40%) met inclusion criteria. Among subjects positive by RSTF guidelines, 45% lacked objective evidence of sinonasal inflammation by CT, 48% by endoscopy, and 34% by either modality. Applying modified RSTF diagnostic criteria, 39% lacked sinonasal inflammation by CT, 38% by endoscopy, and 24% by either modality. Using either abnormal CT or endoscopy as the reference standard, modified diagnostic criteria yielded a statistically significant increase in specificity from 37.1% to 65.1%, with a nonsignificant decrease in sensitivity from 79.2% to 70.3%. Analysis of comorbidities revealed temporomandibular joint disorder, chronic cervical pain, depression/anxiety, and psychiatric medication use to be negatively associated with objective inflammation on CT or endoscopy. Clinical diagnostic criteria overestimate the prevalence of chronic rhinosinusitis. Removing facial pain, ear pain, dental pain, and headache increased specificity without a concordant loss in sensitivity. Given the high prevalence of sinusitis, improved clinical diagnostic criteria may assist primary care providers in more accurately predicting the presence of inflammation, thereby reducing inappropriate antibiotic use or delayed referral for evaluation of primary headache syndromes. 4. Laryngoscope, 127:1011-1016, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  17. Is it useful for distinguishing between benign and malignant solid breast masses?: diagnostic criteria of Japan society of ultrasonics in medicine (JSUM)

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jeong Hee; Kim, Sun Hee; Chung, Chun Phil [Maryknoll Hospital, Busan (Korea, Republic of)

    1995-10-15

    To evaluate the effectiveness and the most accurate element of the diagnostic criteria of the Japan Society of Ultrasonics in medicine (JSUM, Nov. 1989) for distinguishing between benign and malignant solid breast masses on the US. We analyzed the ultrasonic findings of histopathologically proved 51 fibroadenomas, 12 fibrocystic disease, and 39 breast cancers in relation to the diagnostic criteria of the JSUM (shape, border, boundary echo, internal echo, posterior echo, lateral echo, and depth/width ratio). The number of cases of fibroadenoma, fibrocystic disease, and breast cancer corresponding to the diagnostic criteria was in the shape (26/51, 5/12, 33/39), border (41/51, 9/12, 29/39), boundary echo (48/51, 12/12, 27/39) internal echo (43/51, 9/12, 24/39), posterior echo (32/51, 3/12, 21/39), and lateral shadowing (15/51, 1/12, 35/39). All diagnostic criterias showed statistical significance for differentiation of benign/malignant breast mass on the US (Chi-square test: {rho} < 0.05). The order of accuracy was boundary echo, internal echo, and border. The mean of depth/width ratio was 0.54 {+-} 0.15, 0.52 {+-} 0.12, and 0.69 {+-} 0.21 in fibroadenoma, fibrocystic disease, and breast cancer respectively and it had statistical significance for differentiation of benign/malignant breast mass on the US (ANOVA test: {rho} = 0.0002). The diagnostic criteria of JSUM is effective for differentiation of benign/malignant breast solid masses on the US and has accuracy in the order of boundary echo, internal echo, and border. Depth/width ratio also has statistical significance.

  18. Accuracy of cranial coplanar beam therapy using an oblique, stereoscopic x-ray image guidance system

    International Nuclear Information System (INIS)

    Vinci, Justin P.; Hogstrom, Kenneth R.; Neck, Daniel W.

    2008-01-01

    A system for measuring two-dimensional (2D) dose distributions in orthogonal anatomical planes in the cranium was developed and used to evaluate the accuracy of coplanar conformal therapy using ExacTrac image guidance. Dose distributions were measured in the axial, sagittal, and coronal planes using a CIRS (Computerized Imaging Reference Systems, Inc.) anthropomorphic head phantom with a custom internal film cassette. Sections of radiographic Kodak EDR2 film were cut, processed, and digitized using custom templates. Spatial and dosimetric accuracy and precision of the film system were assessed. BrainScan planned a coplanar-beam treatment to conformally irradiate a 2-cm-diameterx2-cm-long cylindrical planning target volume. Prior to delivery, phantom misalignments were imposed in combinations of ±8 mm offsets in each of the principal directions. ExacTrac x-ray correction was applied until the phantom was within an acceptance criteria of 1 mm/1 deg. (first two measurement sets) or 0.4 mm/0.4 deg. (last two measurement sets). Measured dose distributions from film were registered to the treatment plan dose calculations and compared. Alignment errors, displacement between midpoints of planned and measured 70% isodose contours (Δc), and positional errors of the 80% isodose line were evaluated using 49 2D film measurements (98 profiles). Comparison of common, but independent measurements of Δc showed that systematic errors in the measurement technique were 0.2 mm or less along all three anatomical axes and that random error averaged (σ±σ σ ) 0.29±0.06 mm for the acceptance criteria of 1 mm/1 deg. and 0.15±0.02 mm for the acceptance criteria of 0.4 mm/0.4 deg. . The latter was consistent with independent estimates that showed the precision of the measurement system was 0.3 mm (2σ). Values of Δc were as great as 0.9, 0.3, and 1.0 mm along the P-A, R-L, and I-S axes, respectively. Variations in Δc along the P-A axis were correlated to misalignments between laser

  19. Repository operational criteria analysis

    International Nuclear Information System (INIS)

    Hageman, J.P.; Chowdhury, A.H.

    1992-08-01

    The objective of the ''Repository Operational Criteria (ROC) Feasibility Studies'' (or ROC task) was to conduct comprehensive and integrated analyses of repository design, construction, and operations criteria in 10 CFR Part 60 regulations, considering the interfaces and impacts of any potential changes to those regulations. The study addresses regulatory criteria related to the preclosure aspects of the geologic repository. The study task developed regulatory concepts or potential repository operational criteria (PROC) based on analysis of a repository's safety functions and other regulations for similar facilities. These regulatory concepts or PROC were used as a basis to assess the sufficiency and adequacy of the current criteria in 10 CFR Part 60. Where the regulatory concepts were same as current operational criteria, these criteria were referenced. The operations criteria referenced or the PROC developed are given in this report. Detailed analyses used to develop the regulatory concepts and any necessary PROC for those regulations that may require a minor change are also presented. The results of the ROC task showed a need for further analysis and possible major rule change related to the design bases of a geologic repository operations area, siting, and radiological emergency planning

  20. Evaluating the accuracy of uranium isotope amount ratio measurements performed by a quadrupole and a multi-collector magnetic sector inductively coupled plasma mass spectrometers for nuclear safeguards

    International Nuclear Information System (INIS)

    Pereira de Oliveira, O. Jr.; Sarkis, J.E.S.; Ponzevera, E.; Alonso, A.; De Bolle, W.; Quetel, C.

    2008-01-01

    The n(U 235 )/n(U 238 ) isotope amount ratio in a set of samples was measured using two modern analytical techniques: quadrupole inductively coupled plasma mass spectrometry (ICP-QMS) and multi-collector magnetic sector inductively coupled plasma mass spectrometry (MC-ICPMS). The measured ratios were compared to the certified ratios provided by the high accuracy gas source mass spectrometry (GSMS). The components of the uncertainty were identified and their contribution to the combined standard uncertainty was estimated using the recommendations of the ISO-GUM guide. The values of the measurement uncertainty and bias were determined and then compared to the International Target Values for Measurement Uncertainties in Safeguarding Nuclear Materials. It appears that only the measurements performed by MC-ICPMS can meet the stringent requirements of international nuclear safeguards. (authors)

  1. The Impact of Learning Curve Model Selection and Criteria for Cost Estimation Accuracy in the DoD

    Science.gov (United States)

    2016-04-30

    different in the future due to machines” • Heightened scrutiny of cost estimates • Budget Control Act of 2011 seeks to reduce federal deficit ...qÜáêíÉÉåíÜ=^ååì~ä= ^Åèìáëáíáçå=oÉëÉ~êÅÜ= póãéçëáìã= qÜìêëÇ~ó=pÉëëáçåë= sçäìãÉ=ff= = The Impact of Learning Curve Model Selection and Criteria for Cost...Assistant Division Director, Institute for Defense Analyses Bruce Harmon, Research Staff Member, Institute for Defense Analyses The Impact of Learning

  2. Accuracy of ultrasonography in the detection of severe hepatic lipidosis in cats.

    Science.gov (United States)

    Yeager, A E; Mohammed, H

    1992-04-01

    The accuracy of ultrasonography in detection of feline hepatic lipidosis was studied retrospectively. The following ultrasonographic criteria were associated positively with severe hepatic lipidosis: the liver hyperechoic, compared with falciform fat; the liver isoechoic or hyperechoic, compared with omental fat; poor visualization of intrahepatic vessel borders; and increased attenuation of sound by the liver. In a group of 36 cats with clinically apparent hepatobiliary disease and in which liver biopsy was done, liver hyperechoic, compared with falciform fat, was the best criterion for diagnosis of severe hepatic lipidosis with 91% sensitivity, 100% specificity, and 100% positive predictive value.

  3. Basic considerations for the preparation of performance testing materials as related to performance evaluation acceptance criteria

    International Nuclear Information System (INIS)

    McCurdy, D.E.; Morton, J.S.

    2001-01-01

    The preparation of performance testing (PT) materials for environmental and radiobioassay applications involves the use of natural matrix materials containing the analyte of interest, the addition (spiking) of the analyte to a desired matrix (followed by blending for certain matrices) or a combination of the two. The distribution of the sample analyte concentration in a batch of PT samples will reflect the degree of heterogeneity of the analyte in the PT material and/or the reproducibility of the sample preparation process. Commercial and government implemented radioanalytical performance evaluation programs have a variety of acceptable performance criteria. The performance criteria should take into consideration many parameters related to the preparation of the PT materials including the within and between sample analyte heterogeneity, the accuracy of the quantification of an analyte in the PT material and to what 'known' value will a laboratory's result be compared. How sample preparation parameters affect the successful participation in performance evaluation (PE) programs having an acceptance criteria established as a percent difference from a 'known' value or in PE programs using other acceptance criteria, such as the guidance provided in ANSI N42.22 and N13.30 is discussed. (author)

  4. NONLINEAR ASSIGNMENT-BASED METHODS FOR INTERVAL-VALUED INTUITIONISTIC FUZZY MULTI-CRITERIA DECISION ANALYSIS WITH INCOMPLETE PREFERENCE INFORMATION

    OpenAIRE

    TING-YU CHEN

    2012-01-01

    In the context of interval-valued intuitionistic fuzzy sets, this paper develops nonlinear assignment-based methods to manage imprecise and uncertain subjective ratings under incomplete preference structures and thereby determines the optimal ranking order of the alternatives for multiple criteria decision analysis. By comparing each interval-valued intuitionistic fuzzy number's score function, accuracy function, membership uncertainty index, and hesitation uncertainty index, a ranking proced...

  5. Testing the validity and acceptability of the diagnostic criteria for Hoarding Disorder: a DSM-5 survey.

    Science.gov (United States)

    Mataix-Cols, D; Fernández de la Cruz, L; Nakao, T; Pertusa, A

    2011-12-01

    The DSM-5 Obsessive-Compulsive Spectrum Sub-Workgroup is recommending the creation of a new diagnostic category named Hoarding Disorder (HD). The validity and acceptability of the proposed diagnostic criteria have yet to be formally tested. Obsessive-compulsive disorder/hoarding experts and random members of the American Psychiatric Association (APA) were shown eight brief clinical vignettes (four cases meeting criteria for HD, three with hoarding behaviour secondary to other mental disorders, and one with subclinical hoarding behaviour) and asked to decide the most appropriate diagnosis in each case. Participants were also asked about the perceived acceptability of the criteria and whether they supported the inclusion of HD in the main manual. Altogether, 211 experts and 48 APA members completed the survey (30% and 10% response rates, respectively). The sensitivity and specificity of the HD diagnosis and the individual criteria were high (80-90%) across various types of professionals, irrespective of their experience with hoarding cases. About 90% of participants in both samples thought the criteria would be very/somewhat acceptable for professionals and sufferers. Most experts (70%) supported the inclusion of HD in the main manual, whereas only 50% of the APA members did. The proposed criteria for HD have high sensitivity and specificity. The criteria are also deemed acceptable for professionals and sufferers alike. Training of professionals and the development and validation of semi-structured diagnostic instruments should improve diagnostic accuracy even further. A field trial is now needed to confirm these encouraging findings with real patients in real clinical settings.

  6. Accuracy Assessment in Determining the Location of Corners of Building Structures Using a Combination of Various Measurement Methods

    Science.gov (United States)

    Krzyżek, Robert; Przewięźlikowska, Anna

    2017-12-01

    When surveys of corners of building structures are carried out, surveyors frequently use a compilation of two surveying methods. The first one involves the determination of several corners with reference to a geodetic control using classical methods of surveying field details. The second method relates to the remaining corner points of a structure, which are determined in sequence from distance-distance intersection, using control linear values of the wall faces of the building, the so-called tie distances. This paper assesses the accuracy of coordinates of corner points of a building structure, determined using the method of distance-distance intersection, based on the corners which had previously been determined by the conducted surveys tied to a geodetic control. It should be noted, however, that such a method of surveying the corners of building structures from linear measures is based on the details of the first-order accuracy, while the regulations explicitly allow such measurement only for the details of the second- and third-order accuracy. Therefore, a question arises whether this legal provision is unfounded, or whether surveyors are acting not only against the applicable standards but also without due diligence while performing surveys? This study provides answers to the formulated problem. The main purpose of the study was to verify whether the actual method which is used in practice for surveying building structures allows to obtain the required accuracy of coordinates of the points being determined, or whether it should be strictly forbidden. The results of the conducted studies clearly demonstrate that the problem is definitely more complex. Eventually, however, it might be assumed that assessment of the accuracy in determining a location of corners of a building using a combination of two different surveying methods will meet the requirements of the regulation [MIA, 2011), subject to compliance with relevant baseline criteria, which have been

  7. The Quality and Accuracy of Mobile Apps to Prevent Driving After Drinking Alcohol.

    Science.gov (United States)

    Wilson, Hollie; Stoyanov, Stoyan R; Gandabhai, Shailen; Baldwin, Alexander

    2016-08-08

    Driving after the consumption of alcohol represents a significant problem globally. Individual prevention countermeasures such as personalized mobile app aimed at preventing such behavior are widespread, but there is little research on their accuracy and evidence base. There has been no known assessment investigating the quality of such apps. This study aimed to determine the quality and accuracy of apps for drink driving prevention by conducting a review and evaluation of relevant mobile apps. A systematic app search was conducted following PRISMA guidelines. App quality was assessed using the Mobile App Rating Scale (MARS). Apps providing blood alcohol calculators (hereafter "calculators") were reviewed against current alcohol advice for accuracy. A total of 58 apps (30 iOS and 28 Android) met inclusion criteria and were included in the final analysis. Drink driving prevention apps had significantly lower engagement and overall quality scores than alcohol management apps. Most calculators provided conservative blood alcohol content (BAC) time until sober calculations. None of the apps had been evaluated to determine their efficacy in changing either drinking or driving behaviors. This novel study demonstrates that most drink driving prevention apps are not engaging and lack accuracy. They could be improved by increasing engagement features, such as gamification. Further research should examine the context and motivations for using apps to prevent driving after drinking in at-risk populations. Development of drink driving prevention apps should incorporate evidence-based information and guidance, lacking in current apps.

  8. Is it useful for distinguishing between benign and malignant solid breast masses?: diagnostic criteria of Japan society of ultrasonics in medicine (JSUM)

    International Nuclear Information System (INIS)

    Yoon, Jeong Hee; Kim, Sun Hee; Chung, Chun Phil

    1995-01-01

    To evaluate the effectiveness and the most accurate element of the diagnostic criteria of the Japan Society of Ultrasonics in medicine (JSUM, Nov. 1989) for distinguishing between benign and malignant solid breast masses on the US. We analyzed the ultrasonic findings of histopathologically proved 51 fibroadenomas, 12 fibrocystic disease, and 39 breast cancers in relation to the diagnostic criteria of the JSUM (shape, border, boundary echo, internal echo, posterior echo, lateral echo, and depth/width ratio). The number of cases of fibroadenoma, fibrocystic disease, and breast cancer corresponding to the diagnostic criteria was in the shape (26/51, 5/12, 33/39), border (41/51, 9/12, 29/39), boundary echo (48/51, 12/12, 27/39) internal echo (43/51, 9/12, 24/39), posterior echo (32/51, 3/12, 21/39), and lateral shadowing (15/51, 1/12, 35/39). All diagnostic criterias showed statistical significance for differentiation of benign/malignant breast mass on the US (Chi-square test: ρ < 0.05). The order of accuracy was boundary echo, internal echo, and border. The mean of depth/width ratio was 0.54 ± 0.15, 0.52 ± 0.12, and 0.69 ± 0.21 in fibroadenoma, fibrocystic disease, and breast cancer respectively and it had statistical significance for differentiation of benign/malignant breast mass on the US (ANOVA test: ρ = 0.0002). The diagnostic criteria of JSUM is effective for differentiation of benign/malignant breast solid masses on the US and has accuracy in the order of boundary echo, internal echo, and border. Depth/width ratio also has statistical significance

  9. The 2018 Definition of Periprosthetic Hip and Knee Infection: An Evidence-Based and Validated Criteria.

    Science.gov (United States)

    Parvizi, Javad; Tan, Timothy L; Goswami, Karan; Higuera, Carlos; Della Valle, Craig; Chen, Antonia F; Shohat, Noam

    2018-05-01

    The introduction of the Musculoskeletal Infection Society (MSIS) criteria for periprosthetic joint infection (PJI) in 2011 resulted in improvements in diagnostic confidence and research collaboration. The emergence of new diagnostic tests and the lessons we have learned from the past 7 years using the MSIS definition, prompted us to develop an evidence-based and validated updated version of the criteria. This multi-institutional study of patients undergoing revision total joint arthroplasty was conducted at 3 academic centers. For the development of the new diagnostic criteria, PJI and aseptic patient cohorts were stringently defined: PJI cases were defined using only major criteria from the MSIS definition (n = 684) and aseptic cases underwent one-stage revision for a noninfective indication and did not fail within 2 years (n = 820). Serum C-reactive protein (CRP), D-dimer, erythrocyte sedimentation rate were investigated, as well as synovial white blood cell count, polymorphonuclear percentage, leukocyte esterase, alpha-defensin, and synovial CRP. Intraoperative findings included frozen section, presence of purulence, and isolation of a pathogen by culture. A stepwise approach using random forest analysis and multivariate regression was used to generate relative weights for each diagnostic marker. Preoperative and intraoperative definitions were created based on beta coefficients. The new definition was then validated on an external cohort of 222 patients with PJI who subsequently failed with reinfection and 200 aseptic patients. The performance of the new criteria was compared to the established MSIS and the prior International Consensus Meeting definitions. Two positive cultures or the presence of a sinus tract were considered as major criteria and diagnostic of PJI. The calculated weights of an elevated serum CRP (>1 mg/dL), D-dimer (>860 ng/mL), and erythrocyte sedimentation rate (>30 mm/h) were 2, 2, and 1 points, respectively. Furthermore, elevated

  10. Verification of Accuracy of CyberKnife Tumor-tracking Radiation Therapy Using Patient-specific Lung Phantoms

    International Nuclear Information System (INIS)

    Jung, Jinhong; Song, Si Yeol; Yoon, Sang Min; Kwak, Jungwon; Yoon, KyoungJun; Choi, Wonsik; Jeong, Seong-Yun; Choi, Eun Kyung; Cho, Byungchul

    2015-01-01

    Purpose: To investigate the accuracy of the CyberKnife Xsight Lung Tracking System (XLTS) compared with that of a fiducial-based target tracking system (FTTS) using patient-specific lung phantoms. Methods and Materials: Three-dimensional printing technology was used to make individualized lung phantoms that closely mimicked the lung anatomy of actual patients. Based on planning computed tomographic data from 6 lung cancer patients who underwent stereotactic ablative radiation therapy using the CyberKnife, the volume above a certain Hounsfield unit (HU) was assigned as the structure to be filled uniformly with polylactic acid material by a 3-dimensional printer (3D Edison, Lokit, Korea). We evaluated the discrepancies between the measured and modeled target positions, representing the total tracking error, using 3 log files that were generated during each treatment for both the FTTS and the XLTS. We also analyzed the γ index between the film dose measured under the FTTS and XLTS. Results: The overall mean values and standard deviations of total tracking errors for the FTTS were 0.36 ± 0.39 mm, 0.15 ± 0.64 mm, and 0.15 ± 0.62 mm for the craniocaudal (CC), left–right (LR), and anteroposterior (AP) components, respectively. Those for the XLTS were 0.38 ± 0.54 mm, 0.13 ± 0.18 mm, and 0.14 ± 0.37 mm for the CC, LR, and AP components, respectively. The average of γ passing rates was 100% for the criteria of 3%, 3 mm; 99.6% for the criteria of 2%, 2 mm; and 86.8% for the criteria of 1%, 1 mm. Conclusions: The XLTS has segmentation accuracy comparable with that of the FTTS and small total tracking errors

  11. Verification of Accuracy of CyberKnife Tumor-tracking Radiation Therapy Using Patient-specific Lung Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jinhong [Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Department of Radiation Oncology, Kyung Hee University Medical Center, Kyung Hee University School of Medicine, Seoul (Korea, Republic of); Song, Si Yeol, E-mail: coocoori@gmail.com [Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Yoon, Sang Min; Kwak, Jungwon; Yoon, KyoungJun [Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Choi, Wonsik [Department of Radiation Oncology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung (Korea, Republic of); Jeong, Seong-Yun [Asan Institute for Life Science, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Choi, Eun Kyung; Cho, Byungchul [Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2015-07-15

    Purpose: To investigate the accuracy of the CyberKnife Xsight Lung Tracking System (XLTS) compared with that of a fiducial-based target tracking system (FTTS) using patient-specific lung phantoms. Methods and Materials: Three-dimensional printing technology was used to make individualized lung phantoms that closely mimicked the lung anatomy of actual patients. Based on planning computed tomographic data from 6 lung cancer patients who underwent stereotactic ablative radiation therapy using the CyberKnife, the volume above a certain Hounsfield unit (HU) was assigned as the structure to be filled uniformly with polylactic acid material by a 3-dimensional printer (3D Edison, Lokit, Korea). We evaluated the discrepancies between the measured and modeled target positions, representing the total tracking error, using 3 log files that were generated during each treatment for both the FTTS and the XLTS. We also analyzed the γ index between the film dose measured under the FTTS and XLTS. Results: The overall mean values and standard deviations of total tracking errors for the FTTS were 0.36 ± 0.39 mm, 0.15 ± 0.64 mm, and 0.15 ± 0.62 mm for the craniocaudal (CC), left–right (LR), and anteroposterior (AP) components, respectively. Those for the XLTS were 0.38 ± 0.54 mm, 0.13 ± 0.18 mm, and 0.14 ± 0.37 mm for the CC, LR, and AP components, respectively. The average of γ passing rates was 100% for the criteria of 3%, 3 mm; 99.6% for the criteria of 2%, 2 mm; and 86.8% for the criteria of 1%, 1 mm. Conclusions: The XLTS has segmentation accuracy comparable with that of the FTTS and small total tracking errors.

  12. Performance evaluation for epileptic electroencephalogram (EEG) detection by using Neyman-Pearson criteria and a support vector machine

    Science.gov (United States)

    Wang, Chun-mei; Zhang, Chong-ming; Zou, Jun-zhong; Zhang, Jian

    2012-02-01

    The diagnosis of several neurological disorders is based on the detection of typical pathological patterns in electroencephalograms (EEGs). This is a time-consuming task requiring significant training and experience. A lot of effort has been devoted to developing automatic detection techniques which might help not only in accelerating this process but also in avoiding the disagreement among readers of the same record. In this work, Neyman-Pearson criteria and a support vector machine (SVM) are applied for detecting an epileptic EEG. Decision making is performed in two stages: feature extraction by computing the wavelet coefficients and the approximate entropy (ApEn) and detection by using Neyman-Pearson criteria and an SVM. Then the detection performance of the proposed method is evaluated. Simulation results demonstrate that the wavelet coefficients and the ApEn are features that represent the EEG signals well. By comparison with Neyman-Pearson criteria, an SVM applied on these features achieved higher detection accuracies.

  13. Noise pollution mapping approach and accuracy on landscape scales.

    Science.gov (United States)

    Iglesias Merchan, Carlos; Diaz-Balteiro, Luis

    2013-04-01

    Noise mapping allows the characterization of environmental variables, such as noise pollution or soundscape, depending on the task. Strategic noise mapping (as per Directive 2002/49/EC, 2002) is a tool intended for the assessment of noise pollution at the European level every five years. These maps are based on common methods and procedures intended for human exposure assessment in the European Union that could be also be adapted for assessing environmental noise pollution in natural parks. However, given the size of such areas, there could be an alternative approach to soundscape characterization rather than using human noise exposure procedures. It is possible to optimize the size of the mapping grid used for such work by taking into account the attributes of the area to be studied and the desired outcome. This would then optimize the mapping time and the cost. This type of optimization is important in noise assessment as well as in the study of other environmental variables. This study compares 15 models, using different grid sizes, to assess the accuracy of the noise mapping of the road traffic noise at a landscape scale, with respect to noise and landscape indicators. In a study area located in the Manzanares High River Basin Regional Park in Spain, different accuracy levels (Kappa index values from 0.725 to 0.987) were obtained depending on the terrain and noise source properties. The time taken for the calculations and the noise mapping accuracy results reveal the potential for setting the map resolution in line with decision-makers' criteria and budget considerations. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Diagnostic Accuracy of Nonmydriatic Fundus Photography for the Detection of Glaucoma in Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Francisco J. Muñoz-Negrete

    2015-01-01

    Full Text Available Purpose. To determine the diagnostic accuracy for glaucoma of a set of criteria with nonmydriatic monoscopic fundus photography (NMFP in diabetics. Methods. Diabetics recruited from a screening program for diabetic retinopathy and diabetic glaucoma patients recruited from our glaucoma unit were included. Any patient with evidence of diabetic retinopathy was excluded. Diabetic patients had to have no visual field defects to be included as controls. Glaucoma patients had to have a glaucomatous field defect in at least one eye to be included. One NMFP was taken per eye for all subjects. These photographs were evaluated by two masked glaucoma specialists for the presence of the following: bilateral cup to disc (C/D ratio ≥0.6, notching or thinning of the neuroretinal rim, disc hemorrhages, and asymmetry in the C/D ratio between both eyes ≥0.2. This evaluation led to a dichotomous classification: if any of the above criteria was present, the patient was classified as glaucoma. If none were present, the patient was classified as normal. Results. 72 control subjects and 72 glaucoma patients were included. Evaluation of NMFP had a sensitivity of 79.17% and a specificity of 80.56% for specialist 1 and a sensitivity of 72.22% and a specificity of 88.88% for specialist 2 for the detection of glaucoma. The overall accuracy was 79.83% and 80.55%, respectively. Discussion. NMFP evaluation by a glaucoma specialist may be useful for the detection of glaucoma in diabetics.

  15. Criteria CSR

    OpenAIRE

    Vovk, V.; Zateyshikova, O.

    2014-01-01

    In the article the theoretical aspects regarding criteria for assessing CSR proposed by A. Carroll, including: economic, legal, ethical, philanthropic. Based on this, it is proposed to characterize these criteria with respect to the interested parties (stakeholders), including: investors, shareholders suppliers, customers, employees, society and the state. This will make a qualitative assessment of the presence and depth using social responsibility in the company, as well as determine the ext...

  16. SU-E-T-133: Assessing IMRT Treatment Delivery Accuracy and Consistency On a Varian TrueBeam Using the SunNuclear PerFraction EPID Dosimetry Software

    Energy Technology Data Exchange (ETDEWEB)

    Dieterich, S [UC Davis Medical Center, Sacramento, CA (United States); Trestrail, E; Holt, R [Pacific Crest Medical Physics, Chico, CA (United States); Saini, S [Sun Nuclear Corporation, Melbourne, FL (Australia); Pfeiffer, I [VMTH, UC Davis, Davis, CA (United States); Kent, M; Hansen, K [Surgical and Radiological Sciences, UC Davis, Davis, CA (United States)

    2015-06-15

    Purpose: To assess if the TrueBeam HD120 collimator is delivering small IMRT fields accurately and consistently throughout the course of treatment using the SunNuclear PerFraction software. Methods: 7-field IMRT plans for 8 canine patients who passed IMRT QA using SunNuclear Mapcheck DQA were selected for this study. The animals were setup using CBCT image guidance. The EPID fluence maps were captured for each treatment field and each treatment fraction, with the first fraction EPID data serving as the baseline for comparison. The Sun Nuclear PerFraction Software was used to compare the EPID data for subsequent fractions using a Gamma (3%/3mm) pass rate of 90%. To simulate requirements for SRS, the data was reanalyzed using a Gamma (3%/1mm) pass rate of 90%. Low-dose, low- and high gradient thresholds were used to focus the analysis on clinically relevant parts of the dose distribution. Results: Not all fractions could be analyzed, because during some of the treatment courses the DICOM tags in the EPID images intermittently change from CU to US (unspecified), which would indicate a temporary loss of EPID calibration. This technical issue is still being investigated. For the remaining fractions, the vast majority (7/8 of patients, 95% of fractions, and 96.6% of fields) are passing the less stringent Gamma criteria. The more stringent Gamma criteria caused a drop in pass rate (90 % of fractions, 84% of fields). For the patient with the lowest pass rate, wet towel bolus was used. Another patient with low pass rates experienced masseter muscle wasting. Conclusion: EPID dosimetry using the PerFraction software demonstrated that the majority of fields passed a Gamma (3%/3mm) for IMRT treatments delivered with a TrueBeam HD120 MLC. Pass rates dropped for a DTA of 1mm to model SRS tolerances. PerFraction pass rates can flag missing bolus or internal shields. Sanjeev Saini is an employee of Sun Nuclear Corporation. For this study, a pre-release version of PerFRACTION 1

  17. Differentiation of Adrenal Adenoma and Nonadenoma in Unenhanced CT: New Optimal Threshold Value and the Usefulness of Size Criteria for Differentiation

    International Nuclear Information System (INIS)

    Park, Sung Hee; Kim, Myeong Jin; Kim, Joo Hee; Lim, Joon Seok; Kim, Ki Whang

    2007-01-01

    To determine the optimal threshold for the attenuation values in unenhanced computed tomography (CT) and assess the value of the size criteria for differentiating between an adrenal adenoma and a nonadenoma. The unenhanced CT images of 45 patients at our institution, who underwent a surgical resection of an adrenal masses between January 2001 and July 2005, were retrospectively reviewed. Forty-five adrenal masses included 25 cortical adenomas, 12 pheochromocytomas, three lymphomas, and five metastases confirmed by pathology were examined. The CT images were obtained at a slice thickness of 2 mm to 3 mm. The mAs were varied from 100 to 160 and 200 to 280, while the 120 KVp was maintained in all cases. The mean attenuation values of an adrenal adenoma and nonadenoma were compared using an unpaired t test. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy at thresholds of 10 HU, 20 HU, and 25 HU were compared. The diagnostic accuracy according to the size criteria from 2 cm to 6 cm was also compared. The twenty-five adenomas showed significantly lower (p 90% but a specificity < 70%. Size criteria of 2 or 3 cm had a high specificity of 100% and 80% but a low sensitivity of 20% and 60%. The threshold attenuation values of 20 or 25 HU in the unenhanced CT appear optimal for discriminating an adrenal adenoma from a nonadenoma. The size criteria are of little value in differentiating adrenal masses because of their low specificity or low sensitivity

  18. Green Supplier Selection Criteria

    DEFF Research Database (Denmark)

    Nielsen, Izabela Ewa; Banaeian, Narges; Golinska, Paulina

    2014-01-01

    Green supplier selection (GSS) criteria arise from an organization inclination to respond to any existing trends in environmental issues related to business management and processes, so GSS is integrating environmental thinking into conventional supplier selection. This research is designed...... to determine prevalent general and environmental supplier selection criteria and develop a framework which can help decision makers to determine and prioritize suitable green supplier selection criteria (general and environmental). In this research we considered several parameters (evaluation objectives......) to establish suitable criteria for GSS such as their production type, requirements, policy and objectives instead of applying common criteria. At first a comprehensive and deep review on prevalent and green supplier selection literatures performed. Then several evaluation objectives defined to assess the green...

  19. Accuracy of Brief Screening Tools for Identifying Postpartum Depression Among Adolescent Mothers

    Science.gov (United States)

    Venkatesh, Kartik K.; Zlotnick, Caron; Triche, Elizabeth W.; Ware, Crystal

    2014-01-01

    OBJECTIVE: To evaluate the accuracy of the Edinburgh Postnatal Depression Scale (EPDS) and 3 subscales for identifying postpartum depression among primiparous adolescent mothers. METHODS: Mothers enrolled in a randomized controlled trial to prevent postpartum depression completed a psychiatric diagnostic interview and the 10-item EPDS at 6 weeks, 3 months, and 6 months postpartum. Three subscales of the EPDS were assessed as brief screening tools: 3-item anxiety subscale (EPDS-3), 7-item depressive symptoms subscale (EPDS-7), and 2-item subscale (EPDS-2) that resemble the Patient Health Questionnaire-2. Receiver operating characteristic curves and the areas under the curves for each tool were compared to assess accuracy. The sensitivities and specificities of each screening tool were calculated in comparison with diagnostic criteria for a major depressive disorder. Repeated-measures longitudinal analytical techniques were used. RESULTS: A total of 106 women contributed 289 postpartum visits; 18% of the women met criteria for incident postpartum depression by psychiatric diagnostic interview. When used as continuous measures, the full EPDS, EPDS-7, and EPDS-2 performed equally well (area under the curve >0.9). Optimal cutoff scores for a positive depression screen for the EPDS and EPDS-7 were lower (≥9 and ≥7, respectively) than currently recommended cutoff scores (≥10). At optimal cutoff scores, the EPDS and EPDS-7 both had sensitivities of 90% and specificities of >85%. CONCLUSIONS: The EPDS, EPDS-7, and EPDS-2 are highly accurate at identifying postpartum depression among adolescent mothers. In primary care pediatric settings, the EPDS and its shorter subscales have potential for use as effective depression screening tools. PMID:24344102

  20. The accuracy of serum galactomannan assay in diagnosing invasive pulmonary aspergillosis.

    Science.gov (United States)

    Sarrafzadeh, Shokooh Azam; Hoseinpoor Rafati, Ali; Ardalan, Maryam; Mansouri, Davood; Tabarsi, Payam; Pourpak, Zahra

    2010-09-01

    Galactomannan (GM) antigen is an aspergillus specific antigen that is released during the growth phase of invasive aspergillosis. We aimed to find the optimum cutoff and accuracy of serum Galactomannan assay in immunocompromised patients. Immunocompromised patients diagnosed with invasive pulmonary aspergillosis (IPA) based on the European Organization for Research and Treatment of Cancer/Invasive Mycosis Study Group (EORTC/MSG) with three levels of certainty proven, probable and possible, referred for GM antigen measurement at Immunology, Asthma and Allergy Research Institute (IAARI) from 2006 to 2009 and if they met the criteria were enrolled in this study. Totally 49 patients with IPA were enrolled in our study. According to EORTC/MSG, patients categorized into three levels of certainty: They were diagnosed as 'proven' invasive pulmonary aspergillosis 16(32.7%), 'probable' 18(36.7%) and 'possible' 15(30.6%). The most common host risk factor was solid tumors 17(34.7%). The accuracy of Galactomannan assay increased from 0.5 to 2 cutoffs. The optimum sensitivity and specificity obtained at the index cutoff of ≥1.5 for diagnosis of "proven" IPA; which were respectively, 69.2% and 72.2%. Other cutoffs had high variance between sensitivity and specificity for diagnosis of IPA. The calculated cutoff gained by receiver operating characteristic (ROC) analysis for detecting proven IPA was 1.5. Intermediate accuracy of serum GM test in conjunct with clinical findings would help early IPA detection among immunocompromised patients.

  1. Combining the IADPSG criteria with the WHO diagnostic criteria for ...

    African Journals Online (AJOL)

    The International Association of Diabetes in Pregnancy Study Group (IADPSG) and World Health ... Macrosomia or at least one adverse outcome were more likely in GDM patients who ... criteria for GDM in the ADA's more recent position statement.[18] .... at risk for postpartum type 2 DM;[27] the IADPSG criteria on the other ...

  2. Communication: An adaptive configuration interaction approach for strongly correlated electrons with tunable accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Schriber, Jeffrey B.; Evangelista, Francesco A. [Department of Chemistry and Cherry L. Emerson Center for Scientific Computation, Emory University, Atlanta, Georgia 30322 (United States)

    2016-04-28

    We introduce a new procedure for iterative selection of determinant spaces capable of describing highly correlated systems. This adaptive configuration interaction (ACI) determines an optimal basis by an iterative procedure in which the determinant space is expanded and coarse grained until self-consistency. Two importance criteria control the selection process and tune the ACI to a user-defined level of accuracy. The ACI is shown to yield potential energy curves of N{sub 2} with nearly constant errors, and it predicts singlet-triplet splittings of acenes up to decacene that are in good agreement with the density matrix renormalization group.

  3. The criteria for the decision of transrectal US-guided prostate biopsy: Can we reduce the number of unnecessary biopsies?

    International Nuclear Information System (INIS)

    Cho, Joon Hyung; Cho, Jae Ho; Ahn, Jay Hong; Chang, Jay Chun

    2001-01-01

    To establish the criteria which can safely reduce the number of unnecessary biopsies by comparing the transrectal ultrasonography (TRUS) findings, serum prostate-specific antigen (PSA), and prostate specific antigen density (PSAD) in the decision of criteria for the prostatic biopsy using TRUS. Two hundred and twenty patients underwent TRUS- guided prostate biopsy due to elevated PSA and/or focal nodule on TRUS were included. Sixty five (27.5%) patients were confirmed as prostate cancer, and remained 155 (70.5%) patients were reported as benign diseases including benign prostate hyperplasia. The sensitivity, specificity and accuracy of TRUS, PSA and PSAD were evaluated and the single criterion or the combination of the criteria which can safely reduce the unnecessary biopsies without missing prostatic cancer were investigated. The sensitivity, specificity and accuracy of TRUS, PSA (cut-off value, 4 ng/ml) and PSAD (cut-off level, 0.2 ng/ml/cm 3 ) were 78.5%/95.4%/95.4%/27.8%/51.6%/64/5%, 42.7%/64.5%/73.6%, respectively. PSAD cut-off level 0.2 ng/ml/cm 3 was the most excellent single criterion for the decision of prostatic biopsy and the number of unnecessary biopsies was 100 cases. But 3 cases of prostatic cancer which the PSAD level was below 0.2 ng/ml/cm 3 were included and in all these 3 cases, a focal nodule was detected on TRUS. Therefore, we applied these two criteria at once and the biopsies of 30 cases (13.6%) are unnecessary. With the single criterion, we could not obtain the satisfactory results but by the combinations of criteria (TRUS and PSAD), 30 (13.6%) cases are unnecessary biopsies without missing cancer. We think that the short term follow-up may be a substitute for the immediate when nodular lesion is suspicious on TRUS and serum PSAD level is below 0.2 ng/ml/cm 3 .

  4. Proposed radiological criteria for pre-operative determination of resectability in peritoneal-based malignancies

    International Nuclear Information System (INIS)

    Tan, Grace Hwei Ching; Chanyaputhipong, Jendana; Teo, Melissa Ching Ching; Kwek, Jin Wei; Hosseini, Reza; Tham, Chee Kian; Soo, Khee Chee

    2016-01-01

    The selection of patients for cytoreductive surgery (CRS) and hyperthermic intra-peritoneal chemotherapy infusion (HIPEC) is important, and relies heavily on imaging. However, it has been reported that Computer Tomographic (CT) scans may only achieve a low sensitivity of 33% for peritoneal disease. We propose a set of radiological criteria for pre-operative determination of resectability of peritoneal disease in peritoneal-based malignancies and validate this in our cohort of patients. A retrospective review of all patients who underwent laparotomy with a view for CRS and HIPEC, at the National Cancer Centre Singapore from January 2000 to April 2010, was performed. Intra-operative Peritoneal Cancer Index (PCI) scores were recorded. The pre-operative imaging was reviewed with a senior radiologist who was blinded, and recorded the radiological PCI scores (CT-PCI) and eight additional CT prognostic factors (CT-PF). The CT-PCI and CT-PF scores were then compared with the intra-operative findings to determine the radiological accuracy. The scores and the individual prognostic factors were then evaluated for their predictive ability for unresectability. Comparison of the CT-PCI and PCI scores showed a concordance correlation coefficient at 0.52 (95% CI 0.34–0.7). Accuracy was increased with the addition CT-PF. The presence of omental caking and ascites were predictors of unresectability. We propose a scoring system which is able to predict for unresectable disease with a specificity of 80% and a sensitivity of 62%. With our proposed criteria, and scoring system, the selection of patients for CRS and HIPEC can be improved, and unnecessary exploratory operations avoided.

  5. Accuracy of physical self-description among chronic exercisers and non-exercisers

    Directory of Open Access Journals (Sweden)

    Joseph M. Berning

    2014-10-01

    Full Text Available This study addressed the role of chronic exercise to enhance physical self-description as measured by self-estimated percent body fat. Accuracy of physical self-description was determined in normal-weight, regularly exercising and non-exercising males with similar body mass index (BMI’s and females with similar BMI’s (n=42 males and 45 females of which 23 males and 23 females met criteria to be considered chronic exercisers. Statistical analyses were conducted to determine the degree of agreement between self-estimated percent body fat and actual laboratory measurements (hydrostatic weighing. Three statistical techniques were employed: Pearson correlation coefficients, Bland and Altman plots, and regression analysis. Agreement between measured and self-estimated percent body fat was superior for males and females who exercised chronically, compared to non-exercisers. The clinical implications are as follows. Satisfaction with one’s body can be influenced by several factors, including self-perceived body composition. Dissatisfaction can contribute to maladaptive and destructive weight management behaviors. The present study suggests that regular exercise provides a basis for more positive weight management behaviors by enhancing the accuracy of self-assessed body composition.

  6. Design of a basic angle monitoring system in Silicon Carbide

    NARCIS (Netherlands)

    Veggel, van A.A.; Rosielle, P.C.J.N.; Nijmeijer, H.; Wielders, A.A.; Vink, H.J.P.

    2005-01-01

    Due to the 10 microarcsecond accuracy, with which GAIA will measure the positions of stars using 2 astrometric telescopes, stability requirements on the payload module are extremely stringent. In order to achieve the required 10 microarcsecond accuracy, a metrology system could be installed on the

  7. Decision criteria in PSA applications

    International Nuclear Information System (INIS)

    Holmberg, J.E.; Pulkkinen, U.; Rosqvist, T.; Simola, K.

    2001-11-01

    Along with the adoption of risk informed decision making principles, the need for formal probabilistic decision rule or criteria has been risen. However, there are many practical and theoretical problems in the application of probabilistic criteria. One has to think what is the proper way to apply probabilistic rules together with deterministic ones and how the criteria are weighted with respect to each other. In this report, we approach the above questions from the decision theoretic point of view. We give a short review of the most well known probabilistic criteria, and discuss examples of their use. We present a decision analytic framework for evaluating the criteria, and we analyse how the different criteria behave under incompleteness or uncertainty of the PSA model. As the conclusion of our analysis we give recommendations on the application of the criteria in different decision situations. (au)

  8. Bioactive conformational generation of small molecules: A comparative analysis between force-field and multiple empirical criteria based methods

    Directory of Open Access Journals (Sweden)

    Jiang Hualiang

    2010-11-01

    Full Text Available Abstract Background Conformational sampling for small molecules plays an essential role in drug discovery research pipeline. Based on multi-objective evolution algorithm (MOEA, we have developed a conformational generation method called Cyndi in the previous study. In this work, in addition to Tripos force field in the previous version, Cyndi was updated by incorporation of MMFF94 force field to assess the conformational energy more rationally. With two force fields against a larger dataset of 742 bioactive conformations of small ligands extracted from PDB, a comparative analysis was performed between pure force field based method (FFBM and multiple empirical criteria based method (MECBM hybrided with different force fields. Results Our analysis reveals that incorporating multiple empirical rules can significantly improve the accuracy of conformational generation. MECBM, which takes both empirical and force field criteria as the objective functions, can reproduce about 54% (within 1Å RMSD of the bioactive conformations in the 742-molecule testset, much higher than that of pure force field method (FFBM, about 37%. On the other hand, MECBM achieved a more complete and efficient sampling of the conformational space because the average size of unique conformations ensemble per molecule is about 6 times larger than that of FFBM, while the time scale for conformational generation is nearly the same as FFBM. Furthermore, as a complementary comparison study between the methods with and without empirical biases, we also tested the performance of the three conformational generation methods in MacroModel in combination with different force fields. Compared with the methods in MacroModel, MECBM is more competitive in retrieving the bioactive conformations in light of accuracy but has much lower computational cost. Conclusions By incorporating different energy terms with several empirical criteria, the MECBM method can produce more reasonable conformational

  9. Transformation of colour space dedicated to an experimental analysis fulfilling the applicability criteria

    International Nuclear Information System (INIS)

    Ziemba, A; Fornalik-Wajs, E

    2014-01-01

    The choice of colour space is very important in the digital image analysis by reason of accuracy and computational time. Particle Image Velocimetry and Particle Image Thermometry are the optical methods commonly applied in the fluid dynamics and heat transfer. Especially in PIT method, the analysis of colour images is significant. In this paper, transformation of RGB to HSI colour space dedicated to PIT will be presented. Derivation of formulas together with its graphical representation will be discussed. Fulfilment of applicability criteria will be shown. This theoretical approach to digital image processing supplements the knowledge about the optical experimental methods.

  10. Diagnostic accuracy of dual-energy computed tomography in patients with gout: A meta-analysis.

    Science.gov (United States)

    Lee, Young Ho; Song, Gwan Gyu

    2017-08-01

    This study aimed to evaluate the diagnostic performance of dual-energy computed tomography (DECT) for patients with gout. We searched the Medline, Embase, and Cochrane Library databases, and performed a meta-analysis on the diagnostic accuracy of DECT in patients with gout. A total of eight studies including 510 patients with gout and 268 controls (patients with non-gout inflammatory arthritis) were available for the meta-analysis. The pooled sensitivity and specificity of DECT were 84.7% (95% confidence interval [CI]: 81.3-87.7) and 93.7% (93.0-96.3), respectively. The positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 9.882 (6.122-15.95), 0.163 (0.097-0.272), and 78.10 (31.14-195.84), respectively. The area under the curve of DECT was 0.956 and the Q * index was 0.889, indicating a high diagnostic accuracy. Some between-study heterogeneity was found in the meta-analyses. However, there was no evidence of a threshold effect (Spearman correlation coefficient = 0.419; p = 0.035). In addition, meta-regression showed that the sample size, study design, and diagnostic criteria were not sources of heterogeneity, and subgroup meta-analyses did not change the overall diagnostic accuracy. Our meta-analysis of published studies demonstrates that DECT has a high diagnostic accuracy and plays an important role in the diagnosis of gout. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Integration of genomic information into sport horse breeding programs for optimization of accuracy of selection.

    Science.gov (United States)

    Haberland, A M; König von Borstel, U; Simianer, H; König, S

    2012-09-01

    Reliable selection criteria are required for young riding horses to increase genetic gain by increasing accuracy of selection and decreasing generation intervals. In this study, selection strategies incorporating genomic breeding values (GEBVs) were evaluated. Relevant stages of selection in sport horse breeding programs were analyzed by applying selection index theory. Results in terms of accuracies of indices (r(TI) ) and relative selection response indicated that information on single nucleotide polymorphism (SNP) genotypes considerably increases the accuracy of breeding values estimated for young horses without own or progeny performance. In a first scenario, the correlation between the breeding value estimated from the SNP genotype and the true breeding value (= accuracy of GEBV) was fixed to a relatively low value of r(mg) = 0.5. For a low heritability trait (h(2) = 0.15), and an index for a young horse based only on information from both parents, additional genomic information doubles r(TI) from 0.27 to 0.54. Including the conventional information source 'own performance' into the before mentioned index, additional SNP information increases r(TI) by 40%. Thus, particularly with regard to traits of low heritability, genomic information can provide a tool for well-founded selection decisions early in life. In a further approach, different sources of breeding values (e.g. GEBV and estimated breeding values (EBVs) from different countries) were combined into an overall index when altering accuracies of EBVs and correlations between traits. In summary, we showed that genomic selection strategies have the potential to contribute to a substantial reduction in generation intervals in horse breeding programs.

  12. Single- and double- lumen silicone breast implant integrity: prospective evaluation of MR and US criteria.

    Science.gov (United States)

    Berg, W A; Caskey, C I; Hamper, U M; Kuhlman, J E; Anderson, N D; Chang, B W; Sheth, S; Zerhouni, E A

    1995-10-01

    To evaluate the accuracy of magnetic resonance (MR) and ultrasound (US) criteria for breast implant integrity. One hundred twenty-two single-lumen silicone breast implants and 22 bilumen implants were evaluated with surface coil MR imaging and US and surgically removed. MR criteria for implant failure were a collapsed implant shell ("linguine sign"), foci of silicone outside the shell ("noose sign"), and extracapsular gel, US criteria were collapsed shell, low-level echoes within the gel, and "snowstorm" echoes of extracapsular silicone. Among single-lumen implants, MR imaging depicted 39 of 40 ruptures, 14 of 28 with minimal leakage; 49 of 54 intact implants were correctly interpreted. US depicted 26 of 40 ruptured implants, four of 28 with minimal leakage, and 30 of 54 intact implants. Among bilumen implants, MR imaging depicted four of five implants with rupture of both lumina and nine of 10 as intact; US depicted one rupture and helped identify two of 10 as intact. Mammography accurately depicted the status of 29 of 30 bilumen implants with MR imaging correlation. MR imaging depicts implant integrity more accurately than US; neither method reliably depicts minimal leakage with shell collapse. Mammography is useful in screening bilumen implant integrity.

  13. Meditation experience predicts introspective accuracy.

    Directory of Open Access Journals (Sweden)

    Kieran C R Fox

    Full Text Available The accuracy of subjective reports, especially those involving introspection of one's own internal processes, remains unclear, and research has demonstrated large individual differences in introspective accuracy. It has been hypothesized that introspective accuracy may be heightened in persons who engage in meditation practices, due to the highly introspective nature of such practices. We undertook a preliminary exploration of this hypothesis, examining introspective accuracy in a cross-section of meditation practitioners (1-15,000 hrs experience. Introspective accuracy was assessed by comparing subjective reports of tactile sensitivity for each of 20 body regions during a 'body-scanning' meditation with averaged, objective measures of tactile sensitivity (mean size of body representation area in primary somatosensory cortex; two-point discrimination threshold as reported in prior research. Expert meditators showed significantly better introspective accuracy than novices; overall meditation experience also significantly predicted individual introspective accuracy. These results suggest that long-term meditators provide more accurate introspective reports than novices.

  14. Executive summary of the Diagnostic Criteria for Temporomandibular Disorders for clinical and research applications.

    Science.gov (United States)

    Schiffman, Eric; Ohrbach, Richard

    2016-06-01

    In this executive summary, the authors describe a protocol for assessing patients with temporomandibular disorder (TMD). It is based on the Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for clinical and research applications. The DC/TMD was developed using published Axis I physical diagnoses for the most common TMDs. Axis I diagnostic criteria were derived from pertinent clinical TMD signs and symptoms. Axis II consists of psychosocial and behavioral questionnaires already in the public domain. A panel of experts vetted and modified the Axis I and Axis II diagnostic protocols. Recommended changes were assessed for diagnostic accuracy by using the Validation Project's data set, which formed the basis for the development of the DC/TMD. Axis I diagnostic criteria for TMD pain-related disorders have acceptable validity and provide definitive diagnoses for pain involving the temporomandibular joint (TMJ) and masticatory muscles. Axis I diagnostic criteria for the most common TMJ intra-articular disorders are appropriate for screening purposes only. A definitive diagnosis for TMJ intra-articular disorders requires computed tomography or magnetic resonance imaging. Axis II questionnaires provide valid assessment of psychosocial and behavioral factors that can affect management of TMD. The DC/TMD provides a questionnaire for the pain history in conjunction with validated clinical examination criteria for diagnosing the most common TMDs. In addition, it provides Axis II questionnaires for assessing psychosocial and behavioral factors that may contribute to the onset and perpetuation of the patient's TMD. The DC/TMD is appropriate for use in clinical and research settings to allow for a comprehensive assessment of patients with TMD. Copyright © 2016 American Dental Association. Published by Elsevier Inc. All rights reserved.

  15. Continuity between DSM-5 Categorical Criteria and Traits Criteria for Borderline Personality Disorder.

    Science.gov (United States)

    Bach, Bo; Sellbom, Martin

    2016-08-01

    Borderline personality disorder (BPD) includes a heterogeneous constellation of symptoms operationalized with 9 categorical criteria. As the field of personality disorder (PD) research moves to emphasize dimensional traits in its operationalization, it is important to delineate continuity between the 9 DSM-IV/Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) categorical criteria for BPD and the trait dimensions in DSM-5 Section III. To date, no study has attempted such validation. We examined the associations between the 9 categorical DSM-IV/DSM-5 criteria for BPD and the trait dimensions of the alternative DSM-5 model for PDs in consecutively recruited psychiatric outpatients (N = 142; 68% female; age: mean 29.02, SD 8.38). This was investigated by means of bivariate correlations, followed by multiple logistic regression analysis. The categorical BPD criteria were associated with conceptually related DSM-5 Section III traits (P > 0.001), except for the criterion of chronic feelings of emptiness. Consistent with the proposed traits criteria for BPD in DSM-5 Section III, we found Emotional lability, Anxiousness, Separation insecurity, Depressivity, Impulsivity, Risk taking, and Hostility to capture conceptually coherent BPD categorical criteria, while Suspiciousness was also strongly associated with BPD criteria. At the domain level, this applied to Negative affectivity, Disinhibition, and Psychoticism. Notably, Emotional lability, Impulsivity, and Suspiciousness emerged as unique predictors of BPD (P > 0.05). In addition to the proposed BPD traits criteria, Suspiciousness and features of Psychoticism also augment BPD features. Provided that these findings are replicated in forthcoming research, a modified traits operationalization of BPD is warranted. © The Author(s) 2016.

  16. The diagnostic accuracy of carcinoembryonic antigen to detect colorectal cancer recurrence – A systematic review

    DEFF Research Database (Denmark)

    Sørensen, Caspar G; Karlsson, William K; Pommergaard, Hans-Christian

    2016-01-01

    INTRODUCTION: Carcinoembryonic Antigen (CEA) has been used as a tumor marker in the follow-up of colorectal cancer for more than 40 years. Controversy exists regarding its diagnostic applicability due to a relatively low sensitivity and a questionable effect on mortality. The aim of this review...... was to assess the diagnostic accuracy of CEA in detecting recurrence after intended curative surgery for primary colorectal cancer. METHODS: Systematic literature searches were performed in PubMed, EMBASE and Cochrane databases, and articles were chosen based on predefined inclusion criteria. Reference lists...

  17. Diagnostic accuracy of postmortem imaging vs autopsy—A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Eriksson, Anders, E-mail: anders.eriksson@rmv.se [Section of Forensic Medicine, Dept of Community Medicine and Rehabilitation, Umeå University, PO Box 7016, SE-907 12 Umeå (Sweden); Gustafsson, Torfinn [Section of Forensic Medicine, Dept of Community Medicine and Rehabilitation, Umeå University, PO Box 7016, SE-907 12 Umeå (Sweden); Höistad, Malin; Hultcrantz, Monica [Swedish Agency for Health Technology Assessment and Assessment of Social Services, PO Box 3657, SE-103 59 Stockholm (Sweden); Department of Learning, Informatics, Management and Ethics, Karolinska Institutet, SE-171 77 Stockholm (Sweden); Jacobson, Stella; Mejare, Ingegerd [Swedish Agency for Health Technology Assessment and Assessment of Social Services, PO Box 3657, SE-103 59 Stockholm (Sweden); Persson, Anders [Department of Medical and Health Sciences, Center for Medical Image Science and Visualization (CMIV), Linköping University, SE-581 85, Linköping Sweden (Sweden)

    2017-04-15

    Highlights: • The search generated 340 possibly relevant publications, of which 49 were assessed as having high risk of bias and 22 as moderate risk. • Due to considerable heterogeneity of included studies it was impossible to estimate the diagnostic accuracy of the various findings. • Future studies need larger materials and improved planning and methodological quality, preferentially from multi-center studies. - Abstract: Background Postmortem imaging has been used for more than a century as a complement to medico-legal autopsies. The technique has also emerged as a possible alternative to compensate for the continuous decline in the number of clinical autopsies. To evaluate the diagnostic accuracy of postmortem imaging for various types of findings, we performed this systematic literature review. Data sources The literature search was performed in the databases PubMed, Embase and Cochrane Library through January 7, 2015. Relevant publications were assessed for risk of bias using the QUADAS tool and were classified as low, moderate or high risk of bias according to pre-defined criteria. Autopsy and/or histopathology were used as reference standard. Findings The search generated 2600 abstracts, of which 340 were assessed as possibly relevant and read in full-text. After further evaluation 71 studies were finally included, of which 49 were assessed as having high risk of bias and 22 as moderate risk of bias. Due to considerable heterogeneity – in populations, techniques, analyses and reporting – of included studies it was impossible to combine data to get a summary estimate of the diagnostic accuracy of the various findings. Individual studies indicate, however, that imaging techniques might be useful for determining organ weights, and that the techniques seem superior to autopsy for detecting gas Conclusions and Implications In general, based on the current scientific literature, it was not possible to determine the diagnostic accuracy of postmortem

  18. Diagnostic accuracy of postmortem imaging vs autopsy—A systematic review

    International Nuclear Information System (INIS)

    Eriksson, Anders; Gustafsson, Torfinn; Höistad, Malin; Hultcrantz, Monica; Jacobson, Stella; Mejare, Ingegerd; Persson, Anders

    2017-01-01

    Highlights: • The search generated 340 possibly relevant publications, of which 49 were assessed as having high risk of bias and 22 as moderate risk. • Due to considerable heterogeneity of included studies it was impossible to estimate the diagnostic accuracy of the various findings. • Future studies need larger materials and improved planning and methodological quality, preferentially from multi-center studies. - Abstract: Background Postmortem imaging has been used for more than a century as a complement to medico-legal autopsies. The technique has also emerged as a possible alternative to compensate for the continuous decline in the number of clinical autopsies. To evaluate the diagnostic accuracy of postmortem imaging for various types of findings, we performed this systematic literature review. Data sources The literature search was performed in the databases PubMed, Embase and Cochrane Library through January 7, 2015. Relevant publications were assessed for risk of bias using the QUADAS tool and were classified as low, moderate or high risk of bias according to pre-defined criteria. Autopsy and/or histopathology were used as reference standard. Findings The search generated 2600 abstracts, of which 340 were assessed as possibly relevant and read in full-text. After further evaluation 71 studies were finally included, of which 49 were assessed as having high risk of bias and 22 as moderate risk of bias. Due to considerable heterogeneity – in populations, techniques, analyses and reporting – of included studies it was impossible to combine data to get a summary estimate of the diagnostic accuracy of the various findings. Individual studies indicate, however, that imaging techniques might be useful for determining organ weights, and that the techniques seem superior to autopsy for detecting gas Conclusions and Implications In general, based on the current scientific literature, it was not possible to determine the diagnostic accuracy of postmortem

  19. Overlay accuracy fundamentals

    Science.gov (United States)

    Kandel, Daniel; Levinski, Vladimir; Sapiens, Noam; Cohen, Guy; Amit, Eran; Klein, Dana; Vakshtein, Irina

    2012-03-01

    Currently, the performance of overlay metrology is evaluated mainly based on random error contributions such as precision and TIS variability. With the expected shrinkage of the overlay metrology budget to DBO (1st order diffraction based overlay). It is demonstrated that the sensitivity of DBO to overlay mark asymmetry is larger than the sensitivity of imaging overlay. Finally, we show that a recently developed measurement quality metric serves as a valuable tool for improving overlay metrology accuracy. Simulation results demonstrate that the accuracy of imaging overlay can be improved significantly by recipe setup optimized using the quality metric. We conclude that imaging overlay metrology, complemented by appropriate use of measurement quality metric, results in optimal overlay accuracy.

  20. Rating of environmental criteria

    Energy Technology Data Exchange (ETDEWEB)

    Glueck, K; Krasser, G

    1980-01-01

    After a general theoretical discussion on the question of rating within a framework of cost-benefit studies, first trials as to the quantification and standardisation of twelve selected environmental criteria by means of an indicator system are worked out and compiled. The selection includes the criteria exhaust gas, dust, micro climate, water pollution, water regime, land requirement, vibrations, traffic noise, landscape scene, urban scene, effect of separation and safety risks. An insight is given of the rating practice using an evaluation of the available literature, of a household interview and of an interview of experts. The interviewing of 156 experts as to their rating conception of ten criteria in the second round has provided contributions to the general problem of the evaluation estimate based on multi criteria analysis as well as differentiation of the twelve or ten environmental criteria. The following criteria ratings given by the experts and which are averaged and smoothed are: traffic noise 20,0% +- 8,5; air pollution 15,0% +- 7,0; safety risk 13,0% +- 7,0; soil and water pollution 8,5% +- 5,0; landscape scene 8,0% +- 4,5; urban scene 8,0% +- 4,5; water regime 6,5% +- 3,5 and vibrations 4,5% +- 2,5.

  1. Evaluation of 12 blood glucose monitoring systems for self-testing: system accuracy and measurement reproducibility.

    Science.gov (United States)

    Freckmann, Guido; Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Link, Manuela; Haug, Cornelia

    2014-02-01

    Systems for self-monitoring of blood glucose (SMBG) have to provide accurate and reproducible blood glucose (BG) values in order to ensure adequate therapeutic decisions by people with diabetes. Twelve SMBG systems were compared in a standardized manner under controlled laboratory conditions: nine systems were available on the German market and were purchased from a local pharmacy, and three systems were obtained from the manufacturer (two systems were available on the U.S. market, and one system was not yet introduced to the German market). System accuracy was evaluated following DIN EN ISO (International Organization for Standardization) 15197:2003. In addition, measurement reproducibility was assessed following a modified TNO (Netherlands Organization for Applied Scientific Research) procedure. Comparison measurements were performed with either the glucose oxidase method (YSI 2300 STAT Plus™ glucose analyzer; YSI Life Sciences, Yellow Springs, OH) or the hexokinase method (cobas(®) c111; Roche Diagnostics GmbH, Mannheim, Germany) according to the manufacturer's measurement procedure. The 12 evaluated systems showed between 71.5% and 100% of the measurement results within the required system accuracy limits. Ten systems fulfilled with the evaluated test strip lot minimum accuracy requirements specified by DIN EN ISO 15197:2003. In addition, accuracy limits of the recently published revision ISO 15197:2013 were applied and showed between 54.5% and 100% of the systems' measurement results within the required accuracy limits. Regarding measurement reproducibility, each of the 12 tested systems met the applied performance criteria. In summary, 83% of the systems fulfilled with the evaluated test strip lot minimum system accuracy requirements of DIN EN ISO 15197:2003. Each of the tested systems showed acceptable measurement reproducibility. In order to ensure sufficient measurement quality of each distributed test strip lot, regular evaluations are required.

  2. ST segment/heart rate slope as a predictor of coronary artery disease: comparison with quantitative thallium imaging and conventional ST segment criteria

    International Nuclear Information System (INIS)

    Finkelhor, R.S.; Newhouse, K.E.; Vrobel, T.R.; Miron, S.D.; Bahler, R.C.

    1986-01-01

    The ST segment shift relative to exercise-induced increments in heart rate, the ST/heart rate slope (ST/HR slope), has been proposed as a more accurate ECG criterion for diagnosing significant coronary artery disease (CAD). Its clinical utility, with the use of a standard treadmill protocol, was compared with quantitative stress thallium (TI) and standard treadmill criteria in 64 unselected patients who underwent coronary angiography. The overall diagnostic accuracy of the ST/HR slope was an improvement over TI and conventional ST criteria (81%, 67%, and 69%). For patients failing to reach 85% of their age-predicted maximal heart rate, its diagnostic accuracy was comparable with TI (77% and 74%). Its sensitivity in patients without prior myocardial infarctions was equivalent to that of thallium (91% and 95%). The ST/HR slope was directly related to the angiographic severity (Gensini score) of CAD in patients without a prior infarction (r = 0.61, p less than 0.001). The ST/HR slope was an improved ECG criterion for diagnosing CAD and compared favorably with TI imaging

  3. The design of visible system for improving the measurement accuracy of imaging points

    Science.gov (United States)

    Shan, Qiu-sha; Li, Gang; Zeng, Luan; Liu, Kai; Yan, Pei-pei; Duan, Jing; Jiang, Kai

    2018-02-01

    It has a widely applications in robot vision and 3D measurement for binocular stereoscopic measurement technology. And the measure precision is an very important factor, especially in 3D coordination measurement, high measurement accuracy is more stringent to the distortion of the optical system. In order to improving the measurement accuracy of imaging points, to reducing the distortion of the imaging points, the optical system must be satisfied the requirement of extra low distortion value less than 0.1#65285;, a transmission visible optical lens was design, which has characteristic of telecentric beam path in image space, adopted the imaging model of binocular stereo vision, and imaged the drone at the finity distance. The optical system was adopted complex double Gauss structure, and put the pupil stop on the focal plane of the latter groups, maked the system exit pupil on the infinity distance, and realized telecentric beam path in image space. The system mainly optical parameter as follows: the system spectrum rangement is visible light wave band, the optical effective length is f '=30mm, the relative aperture is 1/3, and the fields of view is 21°. The final design results show that the RMS value of the spread spots of the optical lens in the maximum fields of view is 2.3μm, which is less than one pixel(3.45μm) the distortion value is less than 0.1%, the system has the advantage of extra low distortion value and avoids the latter image distortion correction; the proposed modulation transfer function of the optical lens is 0.58(@145 lp/mm), the imaging quality of the system is closed to the diffraction limited; the system has simply structure, and can satisfies the requirements of the optical indexes. Ultimately, based on the imaging model of binocular stereo vision was achieved to measuring the drone at the finity distance.

  4. Analysing and Comparing Encodability Criteria

    Directory of Open Access Journals (Sweden)

    Kirstin Peters

    2015-08-01

    Full Text Available Encodings or the proof of their absence are the main way to compare process calculi. To analyse the quality of encodings and to rule out trivial or meaningless encodings, they are augmented with quality criteria. There exists a bunch of different criteria and different variants of criteria in order to reason in different settings. This leads to incomparable results. Moreover it is not always clear whether the criteria used to obtain a result in a particular setting do indeed fit to this setting. We show how to formally reason about and compare encodability criteria by mapping them on requirements on a relation between source and target terms that is induced by the encoding function. In particular we analyse the common criteria full abstraction, operational correspondence, divergence reflection, success sensitiveness, and respect of barbs; e.g. we analyse the exact nature of the simulation relation (coupled simulation versus bisimulation that is induced by different variants of operational correspondence. This way we reduce the problem of analysing or comparing encodability criteria to the better understood problem of comparing relations on processes.

  5. Diagnostic Criteria for Pediatric MS

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2013-06-01

    Full Text Available Investigators at Northwestern University Feinberg School of Medicine and Ann & Robert H. Lurie Children’s Hospital of Chicago review the diagnostic criteria for pediatric multiple sclerosis, the differential diagnosis, the 2010 McDonald criteria, and Callen criteria.

  6. Kinetic and empirical design criteria for constructed wetlands

    International Nuclear Information System (INIS)

    Nix, P.G.; Gulley, J.R.

    1995-01-01

    A study was conducted to demonstrate the capabilities of wetlands as long-term, self-sustaining natural systems for the treatment of large quantities of waste water released from tailings ponds after mine abandonment. Constructed wetlands were built and planted with aquatic plants. The experimental design included three replicate trenches for each of two treatment systems. The objective of the research was to assess the optimum contaminant loading rates which would result in an acceptable quality of the effluent water. Using empirical data (i.e., hydrocarbon loading rates versus effluent quality), the optimal range of hydrocarbon loading was 5 to 25 gTEH/m 2/ month. Using more conservative kinetic data (i.e. microbial mineralization rates), the range of optimal treatment effectiveness was 9.6 to 13.2 gTEH/m 2/ month. The two design criteria methodologies were calculated using two independent analytical methods. The similarity in results was judged to be a confirmation of their accuracy. 20 refs., 5 figs

  7. The importance of sex-specific quantitative criteria in thallium-201 myocardial scintigraphy

    International Nuclear Information System (INIS)

    Rabinovitch, M.A.; Suissa, S.; Elstein, J.; Turek, M.; Addas, A.; Burgess, J.H.; Rosenthall, L.

    1984-01-01

    Breast attenuation is an important cause of artifactual cold spots on visually interpreted TL-201 myocardial images. This study was undertaken to determine the need for sex-specific criteria in the quantitative analysis of exercise-redistribution TL-201 myocardial scintigraphy (SCINT). The studies of 13 normal females (F) and 12 normal males (M) were processed according to the method of a previous study. Significant sexual differences were found in 7/12 regional uptake (U) proportions, 9/11 regional washout (WO) percentages, 0/3 image redistribution indices, and 0/1 lung to heart ratio. The differences primarily reflected a proportionately decreased anterior and septal uptake in F, a proportionately decreased inferior and inferoapical U in M, and faster WO in F. Sex-specific and total population normal boundaries were set a +- 3SD of the mean for each parameter. Sex-specific boundaries were narrower, and, for 5 parameters (4U and 1WO), contained within the total population boundaries. It was estimated that these differences in boundaries would result in a 6 to 25% discrepancy in patient classification. These results predict that a subset of M and F with coronary artery stenoses could be misclassified as normal by total population criteria, while properly classified as abnormal by sex-specific criteria. The authors conclude that since important differences exist between M and F in the detected pattern of TL-201 myocardial U and WO, sex-specific cr4iteria may enhance the predictive accuracy of SCINT

  8. Accuracy of magnetic resonance studies in the detection of chondral and labral lesions in femoroacetabular impingement: systematic review and meta-analysis.

    Science.gov (United States)

    Saied, A M; Redant, C; El-Batouty, M; El-Lakkany, M R; El-Adl, W A; Anthonissen, J; Verdonk, R; Audenaert, E A

    2017-02-16

    Several types of Magnetic resonance imaging (MRI) are commonly used in imaging of femoroacetabular impingement (FAI), however till now there are no clear protocols and recommendations for each type. The aim of this meta-analysis is to detect the accuracy of conventional magnetic resonance imaging (cMRI), direct magnetic resonance arthrography (dMRA) and indirect magnetic resonance arthrography (iMRA) in the diagnosis of chondral and labral lesions in femoroacetabular impingement (FAI). A literature search was finalized on the 17th of May 2016 to collect all studies identifying the accuracy of cMRI, dMRA and iMRA in diagnosing chondral and labral lesions associated with FAI using surgical results (arthroscopic or open) as a reference test. Pooled sensitivity and specificity with 95% confidence intervals using a random-effects meta-analysis for MRI, dMRA and iMRA were calculated also area under receiver operating characteristic (ROC) curve (AUC) was retrieved whenever possible where AUC is equivocal to diagnostic accuracy. The search yielded 192 publications which were reviewed according inclusion and exclusion criteria then 21 studies fulfilled the eligibility criteria for the qualitative analysis with a total number of 828 cases, lastly 12 studies were included in the quantitative meta-analysis. Meta-analysis showed that as regard labral lesions the pooled sensitivity, specificity and AUC for cMRI were 0.864, 0.833 and 0.88 and for dMRA were 0.91, 0.58 and 0.92. While in chondral lesions the pooled sensitivity, specificity and AUC for cMRI were 0.76, 0.72 and 0.75 and for dMRA were 0.75, 0.79 and 0.83, while for iMRA were sensitivity of 0.722 and specificity of 0.917. The present meta-analysis showed that the diagnostic test accuracy was superior for dMRA when compared with cMRI for detection of labral and chondral lesions. The diagnostic test accuracy was superior for labral lesions when compared with chondral lesions in both cMRI and dMRA. Promising results are

  9. The effect of search term on the quality and accuracy of online information regarding distal radius fractures.

    Science.gov (United States)

    Dy, Christopher J; Taylor, Samuel A; Patel, Ronak M; Kitay, Alison; Roberts, Timothy R; Daluiski, Aaron

    2012-09-01

    Recent emphasis on shared decision making and patient-centered research has increased the importance of patient education and health literacy. The internet is rapidly growing as a source of self-education for patients. However, concern exists over the quality, accuracy, and readability of the information. Our objective was to determine whether the quality, accuracy, and readability of information online about distal radius fractures vary with the search term. This was a prospective evaluation of 3 search engines using 3 different search terms of varying sophistication ("distal radius fracture," "wrist fracture," and "broken wrist"). We evaluated 70 unique Web sites for quality, accuracy, and readability. We used comparative statistics to determine whether the search term affected the quality, accuracy, and readability of the Web sites found. Three orthopedic surgeons independently gauged quality and accuracy of information using a set of predetermined scoring criteria. We evaluated the readability of the Web site using the Fleisch-Kincaid score for reading grade level. There were significant differences in the quality, accuracy, and readability of information found, depending on the search term. We found higher quality and accuracy resulted from the search term "distal radius fracture," particularly compared with Web sites resulting from the term "broken wrist." The reading level was higher than recommended in 65 of the 70 Web sites and was significantly higher when searching with "distal radius fracture" than "wrist fracture" or "broken wrist." There was no correlation between Web site reading level and quality or accuracy. The readability of information about distal radius fractures in most Web sites was higher than the recommended reading level for the general public. The quality and accuracy of the information found significantly varied with the sophistication of the search term used. Physicians, professional societies, and search engines should consider

  10. Neurophysiological localisation of ulnar neuropathy at the elbow: Validation of diagnostic criteria developed by a taskforce of the Danish Society of clinical neurophysiology.

    Science.gov (United States)

    Pugdahl, K; Beniczky, S; Wanscher, B; Johnsen, B; Qerama, E; Ballegaard, M; Benedek, K; Juhl, A; Ööpik, M; Selmar, P; Sønderborg, J; Terney, D; Fuglsang-Frederiksen, A

    2017-11-01

    This study validates consensus criteria for localisation of ulnar neuropathy at elbow (UNE) developed by a taskforce of the Danish Society of Clinical Neurophysiology and compares them to the existing criteria from the American Association of Neuromuscular and Electrodiagnostic Medicine (AANEM). The Danish criteria are based on combinations of conduction slowing in the segments of the elbow and forearm expressed in Z-scores, and difference between the segments in m/s. Examining fibres to several muscles and sensory fibres can increase the certainty of the localisation. Diagnostic accuracy for UNE was evaluated on 181 neurophysiological studies of the ulnar nerve from 171 peer-reviewed patients from a mixed patient-group. The diagnostic reference standard was the consensus diagnosis based on all available clinical, laboratory, and electrodiagnostic information reached by a group of experienced Danish neurophysiologists. The Danish criteria had high specificity (98.4%) and positive predictive value (PPV) (95.2%) and fair sensitivity (76.9%). Compared to the AANEM criteria, the Danish criteria had higher specificity (p<0.001) and lower sensitivity (p=0.02). The Danish consensus criteria for UNE are very specific and have high PPV. The Danish criteria for UNE are reliable and well suited for use in different centres as they are based on Z-scores. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  11. Sampling strategies for improving tree accuracy and phylogenetic analyses: a case study in ciliate protists, with notes on the genus Paramecium.

    Science.gov (United States)

    Yi, Zhenzhen; Strüder-Kypke, Michaela; Hu, Xiaozhong; Lin, Xiaofeng; Song, Weibo

    2014-02-01

    In order to assess how dataset-selection for multi-gene analyses affects the accuracy of inferred phylogenetic trees in ciliates, we chose five genes and the genus Paramecium, one of the most widely used model protist genera, and compared tree topologies of the single- and multi-gene analyses. Our empirical study shows that: (1) Using multiple genes improves phylogenetic accuracy, even when their one-gene topologies are in conflict with each other. (2) The impact of missing data on phylogenetic accuracy is ambiguous: resolution power and topological similarity, but not number of represented taxa, are the most important criteria of a dataset for inclusion in concatenated analyses. (3) As an example, we tested the three classification models of the genus Paramecium with a multi-gene based approach, and only the monophyly of the subgenus Paramecium is supported. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. 100% classification accuracy considered harmful: the normalized information transfer factor explains the accuracy paradox.

    Directory of Open Access Journals (Sweden)

    Francisco J Valverde-Albacete

    Full Text Available The most widely spread measure of performance, accuracy, suffers from a paradox: predictive models with a given level of accuracy may have greater predictive power than models with higher accuracy. Despite optimizing classification error rate, high accuracy models may fail to capture crucial information transfer in the classification task. We present evidence of this behavior by means of a combinatorial analysis where every possible contingency matrix of 2, 3 and 4 classes classifiers are depicted on the entropy triangle, a more reliable information-theoretic tool for classification assessment. Motivated by this, we develop from first principles a measure of classification performance that takes into consideration the information learned by classifiers. We are then able to obtain the entropy-modulated accuracy (EMA, a pessimistic estimate of the expected accuracy with the influence of the input distribution factored out, and the normalized information transfer factor (NIT, a measure of how efficient is the transmission of information from the input to the output set of classes. The EMA is a more natural measure of classification performance than accuracy when the heuristic to maximize is the transfer of information through the classifier instead of classification error count. The NIT factor measures the effectiveness of the learning process in classifiers and also makes it harder for them to "cheat" using techniques like specialization, while also promoting the interpretability of results. Their use is demonstrated in a mind reading task competition that aims at decoding the identity of a video stimulus based on magnetoencephalography recordings. We show how the EMA and the NIT factor reject rankings based in accuracy, choosing more meaningful and interpretable classifiers.

  13. Diagnosing Eyewitness Accuracy

    OpenAIRE

    Russ, Andrew

    2015-01-01

    Eyewitnesses frequently mistake innocent people for the perpetrator of an observed crime. Such misidentifications have led to the wrongful convictions of many people. Despite this, no reliable method yet exists to determine eyewitness accuracy. This thesis explored two new experimental methods for this purpose. Chapter 2 investigated whether repetition priming can measure prior exposure to a target and compared this with observers’ explicit eyewitness accuracy. Across three experiments slower...

  14. Automatic Enhancement of the Reference Set for Multi-Criteria Sorting in The Frame of Theseus Method

    Directory of Open Access Journals (Sweden)

    Fernandez Eduardo

    2014-05-01

    Full Text Available Some recent works have established the importance of handling abundant reference information in multi-criteria sorting problems. More valid information allows a better characterization of the agent’s assignment policy, which can lead to an improved decision support. However, sometimes information for enhancing the reference set may be not available, or may be too expensive. This paper explores an automatic mode of enhancing the reference set in the framework of the THESEUS multi-criteria sorting method. Some performance measures are defined in order to test results of the enhancement. Several theoretical arguments and practical experiments are provided here, supporting a basic advantage of the automatic enhancement: a reduction of the vagueness measure that improves the THESEUS accuracy, without additional efforts from the decision agent. The experiments suggest that the errors coming from inadequate automatic assignments can be kept at a manageable level.

  15. Trait Perception Accuracy and Acquaintance Within Groups: Tracking Accuracy Development.

    Science.gov (United States)

    Brown, Jill A; Bernieri, Frank

    2017-05-01

    Previous work on trait perception has evaluated accuracy at discrete stages of relationships (e.g., strangers, best friends). A relatively limited body of literature has investigated changes in accuracy as acquaintance within a dyad or group increases. Small groups of initially unacquainted individuals spent more than 30 hr participating in a wide range of activities designed to represent common interpersonal contexts (e.g., eating, traveling). We calculated how accurately each participant judged others in their group on the big five traits across three distinct points within the acquaintance process: zero acquaintance, after a getting-to-know-you conversation, and after 10 weeks of interaction and activity. Judgments of all five traits exhibited accuracy above chance levels after 10 weeks. An examination of the trait rating stability revealed that much of the revision in judgments occurred not over the course of the 10-week relationship as suspected, but between zero acquaintance and the getting-to-know-you conversation.

  16. Dual Criteria Decisions

    DEFF Research Database (Denmark)

    Andersen, Steffen; Harrison, Glenn W.; Lau, Morten Igel

    2014-01-01

    The most popular models of decision making use a single criterion to evaluate projects or lotteries. However, decision makers may actually consider multiple criteria when evaluating projects. We consider a dual criteria model from psychology. This model integrates the familiar tradeoffs between...... to the clear role that income thresholds play in such decision making, but does not rule out a role for tradeoffs between risk and utility or probability weighting....

  17. Diagnostic accuracy of postmortem imaging vs autopsy-A systematic review.

    Science.gov (United States)

    Eriksson, Anders; Gustafsson, Torfinn; Höistad, Malin; Hultcrantz, Monica; Jacobson, Stella; Mejare, Ingegerd; Persson, Anders

    2017-04-01

    Background Postmortem imaging has been used for more than a century as a complement to medico-legal autopsies. The technique has also emerged as a possible alternative to compensate for the continuous decline in the number of clinical autopsies. To evaluate the diagnostic accuracy of postmortem imaging for various types of findings, we performed this systematic literature review. Data sources The literature search was performed in the databases PubMed, Embase and Cochrane Library through January 7, 2015. Relevant publications were assessed for risk of bias using the QUADAS tool and were classified as low, moderate or high risk of bias according to pre-defined criteria. Autopsy and/or histopathology were used as reference standard. Findings The search generated 2600 abstracts, of which 340 were assessed as possibly relevant and read in full-text. After further evaluation 71 studies were finally included, of which 49 were assessed as having high risk of bias and 22 as moderate risk of bias. Due to considerable heterogeneity - in populations, techniques, analyses and reporting - of included studies it was impossible to combine data to get a summary estimate of the diagnostic accuracy of the various findings. Individual studies indicate, however, that imaging techniques might be useful for determining organ weights, and that the techniques seem superior to autopsy for detecting gas Conclusions and Implications In general, based on the current scientific literature, it was not possible to determine the diagnostic accuracy of postmortem imaging and its usefulness in conjunction with, or as an alternative to autopsy. To correctly determine the usefulness of postmortem imaging, future studies need improved planning, improved methodological quality and larger materials, preferentially obtained from multi-center studies. Copyright © 2016. Published by Elsevier B.V.

  18. Failure Criteria for Reinforced Materials

    DEFF Research Database (Denmark)

    Rathkjen, Arne

    Failure of materials is often characterized as ductile yielding, brittle fracture, creep rupture, etc., and different criteria given in terms of different parameters have been used to describe different types of failure. Only criteria expressing failure in terms of stress are considered in what...... place until the matrix, the continuous component of the composite, fails. When an isotropic matrix is reinforced as described above, the result is an anisotropic composite material. Even if the material is anisotropic, it usually exhibits a rather high degree of symmetry and such symmetries place...... certain restrictions on the form of the failure criteria for anisotropic materials. In section 2, some failure criteria for homogenous materials are reviewed. Both isotropic and anisotropic materials are described, and in particular the constraints imposed on the criteria from the symmetries orthotropy...

  19. Design criteria for confidence in the manufacture of BWR fuel rods

    International Nuclear Information System (INIS)

    Anantharaman, K.; Basu, S.; Anand, A.K.; Mehta, S.K.

    Based on the experience of fuel manufacture for BWR type reactors in India, the parameters which need stringent quality control, are discussed. The design specifications of the fuel rods as well as the cladding material and tubes are reported. The defect mechanisms to be taken into account and the fuel failure in reference to the variation of mechanical properties of the cladding are also described. (K.B.)

  20. Defining criteria related to wastes for use in multi-criteria decision tool for nuclear accidents

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Diogo N.G.; Guimaraes, Jean R.D., E-mail: dneves@biof.ufrj.br, E-mail: jeanrdg@biof.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Instituto de Biofisica Carlos Chagas Filho; Rochedo, Elaine R.R.; De Luca, Christiano, E-mail: elainerochedo@gmail.com, E-mail: christiano_luca@hotmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Rochedo, Pedro R.R., E-mail: rochedopedro@gmail.com [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Instituto Alberto Luiz Coimbra de Pos-Graduacao e Pesquisa de Engenharia

    2013-07-01

    The selection of protective measures and strategies for remediation of contaminated areas after a nuclear accident must be based on previously established criteria in order to prevent stress of the population and the unnecessary exposure of workers. After a nuclear accident resulting in environmental contamination, decisions on remediation of areas is complex due to the large numbers of factors involved in decontamination processes. This work is part of a project which aims to develop a multi-criteria tool to support a decision-making process in cases of a radiological or a nuclear accident in Brazil. First, a database of remediation strategies for contaminated areas was created. In this process, the most relevant aspects for the implementation of these strategies were considered, including technical criteria regarding aspects related to the generation of wastes in a reference urban area, which are discussed in this paper. The specific objective of this study is to define criteria for the aspects of radioactive wastes, resulted by the implementation of some urban measures, in order to be incorporated in a multi-criteria decision tool. Main aspects considered were the type, the amount and the type of treatment necessary for each procedure. The decontamination procedures are then classified according to the selected criteria in order to feed the multi-criteria decision tool. This paper describes the steps for the establishment of these criteria and evaluates the potential for future applications in order to improve predictions and to support the decisions to be made. (author)

  1. Defining criteria related to wastes for use in multi-criteria decision tool for nuclear accidents

    International Nuclear Information System (INIS)

    Silva, Diogo N.G.; Guimaraes, Jean R.D.; Rochedo, Elaine R.R.; De Luca, Christiano; Rochedo, Pedro R.R.

    2013-01-01

    The selection of protective measures and strategies for remediation of contaminated areas after a nuclear accident must be based on previously established criteria in order to prevent stress of the population and the unnecessary exposure of workers. After a nuclear accident resulting in environmental contamination, decisions on remediation of areas is complex due to the large numbers of factors involved in decontamination processes. This work is part of a project which aims to develop a multi-criteria tool to support a decision-making process in cases of a radiological or a nuclear accident in Brazil. First, a database of remediation strategies for contaminated areas was created. In this process, the most relevant aspects for the implementation of these strategies were considered, including technical criteria regarding aspects related to the generation of wastes in a reference urban area, which are discussed in this paper. The specific objective of this study is to define criteria for the aspects of radioactive wastes, resulted by the implementation of some urban measures, in order to be incorporated in a multi-criteria decision tool. Main aspects considered were the type, the amount and the type of treatment necessary for each procedure. The decontamination procedures are then classified according to the selected criteria in order to feed the multi-criteria decision tool. This paper describes the steps for the establishment of these criteria and evaluates the potential for future applications in order to improve predictions and to support the decisions to be made. (author)

  2. Prediction of nodal involvement in primary rectal carcinoma without invasion to pelvic structures: accuracy of preoperative CT, MR, and DWIBS assessments relative to histopathologic findings.

    Directory of Open Access Journals (Sweden)

    Jun Zhou

    Full Text Available OBJECTIVE: To investigate the accuracy of preoperative computed tomography (CT, magnetic resonance (MR imaging and diffusion-weighted imaging with background body signal suppression (DWIBS in the prediction of nodal involvement in primary rectal carcinoma patients in the absence of tumor invasion into pelvic structures. METHODS AND MATERIALS: Fifty-two subjects with primary rectal cancer were preoperatively assessed by CT and MRI at 1.5 T with a phased-array coil. Preoperative lymph node staging with imaging modalities (CT, MRI, and DWIBS were compared with the final histological findings. RESULTS: The accuracy of CT, MRI, and DWIBS were 57.7%, 63.5%, and 40.4%. The accuracy of DWIBS with higher sensitivity and negative predictive value for evaluating primary rectal cancer patients was lower than that of CT and MRI. Nodal staging agreement between imaging and pathology was fairly strong for CT and MRI (Kappa value = 0.331 and 0.348, P<0.01 but was relatively weaker for DWIBS (Kappa value = 0.174, P<0.05. The accuracy was 57.7% and 59.6%, respectively, for CT and MRI when the lymph node border information was used as the criteria, and was 57.7% and 61.5%, respectively, for enhanced CT and MRI when the lymph node enhancement pattern was used as the criteria. CONCLUSION: MRI is more accurate than CT in predicting nodal involvement in primary rectal carcinoma patients in the absence of tumor invasion into pelvic structures. DWIBS has a great diagnostic value in differentiating small malignant from benign lymph nodes.

  3. Comparing new diagnostic criteria of 2010 ACR/EULAR with 1987 ACR criteria in rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Fatemeh Shirani

    2017-01-01

    Full Text Available Background: Rheumatoid Arthritis (RA is a chronic inflammatory disease presenting with inflammation, tenderness and destruction of the synovial joints, resulting in severe disability and early death due to complication of disease. Previous diagnostic criteria are not useful for identifying patients who need early treatment. Thus, new diagnostic criteria for faster diagnosis of disease are introduced in 2010. The aim of this study was to compared 1987 ACR (American College of Rheumatology criteria and 2010 ACR/EULAR (European League Against Rheumatism classification criteria for diagnosis of rheumatoid arthritis. Methods: In this Cohort prospective study, patients with early arthritis were evaluated   according to the old and new diagnostic criteria and followed-up every two monthly for one year (2012-2013 in Hazrat-e Rasool University Hospital, Tehran. Inclusion criteria of this study were age more than 18 year and indefinite diagnosis of arthritis. For all of patients physical examination by expert rheumatologist was done and lab data include erythrocyte sedimentation rate (ESR, C-reactive protein (CRP, anti-cyclic citrullinated peptide (Anti-CCP and rheumatoid factor was requested. The sensitivity, specificity, positive and negative predictive values were then determined for each diagnostic criteria. Results: In this study 104 patients including 28 males (26.9% and 76 females (73.1% with the mean age of 44.2±13.7 years were included. At the end of one year follow-up, 82 were diagnosed to have RA while other 22 patients were not categorized as RA. Sensitivity for ESR, CRP, Anti-CCP and rheumatoid factor in 2010 ACR/EULAR criteria was 52%, 19%, 48%, 28% and specificity for them was 45%, 71%, 27%, 79% respectively. Number of small and large joint arthritis were more in patients with Rheumatoid Arthritis (RA rather than other arthritis (P=0.0001. Sensitivity and specificity for small joints involvement was 87% and 54% and for large joints

  4. Quality assurance of intensity-modulated radiation therapy.

    Science.gov (United States)

    Palta, Jatinder R; Liu, Chihray; Li, Jonathan G

    2008-01-01

    The current paradigm for the quality assurance (QA) program for intensity-modulated radiation therapy (IMRT) includes QA of the treatment planning system, QA of the delivery system, and patient-specific QA. Although the IMRT treatment planning and delivery system is the same as for conventional three-dimensional conformal radiation therapy, it has more parameters to coordinate and verify. Because of complex beam intensity modulation, each IMRT field often includes many small irregular off-axis fields, resulting in isodose distributions for each IMRT plan that are more conformal than those from conventional treatment plans. Therefore, these features impose a new and more stringent set of QA requirements for IMRT planning and delivery. The generic test procedures to validate dose calculation and delivery accuracy for both treatment planning and IMRT delivery have to be customized for each type of IMRT planning and delivery strategy. The rationale for such an approach is that the overall accuracy of IMRT delivery is incumbent on the piecewise uncertainties in both the planning and delivery processes. The end user must have well-defined evaluation criteria for each element of the planning and delivery process. Such information can potentially be used to determine a priori the accuracy of IMRT planning and delivery.

  5. Quality Assurance of Intensity-Modulated Radiation Therapy

    International Nuclear Information System (INIS)

    Palta, Jatinder R.; Liu, Chihray; Li, Jonathan G.

    2008-01-01

    The current paradigm for the quality assurance (QA) program for intensity-modulated radiation therapy (IMRT) includes QA of the treatment planning system, QA of the delivery system, and patient-specific QA. Although the IMRT treatment planning and delivery system is the same as for conventional three-dimensional conformal radiation therapy, it has more parameters to coordinate and verify. Because of complex beam intensity modulation, each IMRT field often includes many small irregular off-axis fields, resulting in isodose distributions for each IMRT plan that are more conformal than those from conventional treatment plans. Therefore, these features impose a new and more stringent set of QA requirements for IMRT planning and delivery. The generic test procedures to validate dose calculation and delivery accuracy for both treatment planning and IMRT delivery have to be customized for each type of IMRT planning and delivery strategy. The rationale for such an approach is that the overall accuracy of IMRT delivery is incumbent on the piecewise uncertainties in both the planning and delivery processes. The end user must have well-defined evaluation criteria for each element of the planning and delivery process. Such information can potentially be used to determine a priori the accuracy of IMRT planning and delivery

  6. Diagnostic Accuracy of Clinical Methods for Detection of Diabetic Sensory Neuropathy

    International Nuclear Information System (INIS)

    Arshad, A. R.; Alvi, K. Y.

    2016-01-01

    Objective: To determine the accuracy of clinical methods for detection of sensory neuropathy as compared to biothesiometry. Study Design: Cross-sectional analytical study. Place and Duration of Study: 1 Mountain Medical Battalion, Azad Kashmir, from October 2013 to September 2014. Methodology: Patients with type 2 diabetes were enrolled by convenience sampling. Exclusion criteria included other identifiable causes of neuropathy, extensive ulceration of feet, amputated feet, those on treatment for neuropathy and unwilling patients. Average of 3 vibration perception threshold values measured with a biothesiometer on distal hallux was calculated. Ten gm monofilament was used to examine touch sensation over dorsal surfaces of great toes. Vibration sensation was checked over the tips of great toes using 128Hz tuning fork. Ankle jerks were checked bilaterally. Result: Neuropathy (vibration perception threshold > 25 volts) was present in 34 (21.12 percentage) out of 161 patients and 93 (57.76 percentage) were symptomatic. Measures of diagnostic accuracy for monofilament, tuning fork and ankle jerks were: sensitivity 41.18 percentage, 55.88 percentage and 64.71 percentage; specificity 92.91 percentage, 93.70 percentage and 80.31 percentage; positive predictive value (PPV) 60.87 percentage, 70.37 percentage and 46.81 percentage; negative predictive value (NPV) 85.51 percentage, 88.81 percentage and 89.47 percentage; and, diagnostic accuracy 81.99 percentage, 85.71 percentage and 77.02 percentage, respectively. Values for any 1 positive sign, any 2 positive signs or all 3 positive signs were: sensitivity 35.29 percentage, 14.71 percentage and 32.35 percentage; specificity 81.89 percentage, 93.70 percentage and 99.21 percentage; PPV 34.29 percentage, 38.46 percentage and 91.67 percentage; NPV 82.54 percentage, 80.41 percentage and 84.56 percentage; and, diagnostic accuracy 72.05 percentage, 77.02 percentage and 85.09 percentage, respectively. Conclusion: Clinical methods are

  7. Extrapolating power-ramp performance criteria for current and advanced CANDU fuels

    Energy Technology Data Exchange (ETDEWEB)

    Tayal, M.; Chassie, G.G

    2000-06-01

    To improve the precision and accuracy of power-ramp performance criteria for high-burnup fuel, we have examined in-reactor fuel performance data as well as out-reactor test data. The data are consistent with some of the concepts used in the current formulations for defining fuel failure thresholds, such as size of power-ramp and extent of burnup. Our review indicates that there is a need to modify some other aspects of the current formulations; therefore, a modified formulation is presented in this paper. The improvements mainly concern corrodent concentration and its relationships with threshold stress for failure. The new formulation is consistent with known and expected trends such as strength of Zircaloy in corrosive environment, timing of the release of fission products to the pellet-to-sheath gap, CANLUB coating, and fuel burnup. Because of the increased precision and accuracy, the new formulation is better able to identify operational regimes that are at risk of power-ramp failures; this predictive ability provides enhanced protection to fuel against power-ramp defects. At die same time, by removing unnecessary conservatisms in other areas, the new formulation permits a greater range of defect-free operational envelope as well as larger operating margins in regions that are, in fact, not prone to power-ramp failures. (author)

  8. Safety and licensing of MHTGR [Modular High Temperature Gas Cooled Reactor

    International Nuclear Information System (INIS)

    Silady, F.A.; Millunzi, A.C.; Kelley, A.P. Jr.; Cunliffe, J.

    1987-07-01

    The Modular High Temperature Gas Cooled Reactor (MHTGR) design meets stringent top-level regulatory and user safety requirements that require that the normal and off-normal operation of the plant not disturb the public's day-to-day activities. Quantitative, top-level regulatory criteria have been specified from US NRC and EPA sources to guide the design. The user/utility group has further specified that these criteria be met at the plant boundary. The focus of the safety approach has then been centered on retaining the radionuclide inventory within the fuel by removing core heat, controlling chemical attack, and by controlling heat generation. The MHTGR is shown to passively meet the stringent requirements with margin. No operator action is required and the plant is insensitive to operator error

  9. Cognitive impairment in the remitted state of unipolar depressive disorder: A systematic review

    DEFF Research Database (Denmark)

    Hasselbalch, Bo Jacob; Knorr, Ulla; Kessing, Lars Vedel

    2010-01-01

    BACKGROUND: It is unclear whether cognitive impairment is prevalent in the remitted state of unipolar disorder. AIM: To evaluate whether cognitive function is impaired in the remitted state in patients with unipolar depression compared with healthy control individuals, and to investigate...... were prevalent including non-stringent definition of remission and non-correction for multiple testing. Only few studies investigated the association between cognition and prior course of illness and the results were divergent. LIMITATIONS: Stringent criteria were used in the assessment of eligibility...... of studies. The studies were first and foremost selected according to the criteria for remission used. CONCLUSION: Cognitive dysfunction seems to be present in individuals suffering from unipolar disorder in the remitted state. We recommend that future studies should focus on disentangling the state...

  10. Accuracy of chemical shift MR imaging in diagnosing indeterminate bone marrow lesions in the pelvis: review of a single institution's experience

    International Nuclear Information System (INIS)

    Kohl, Chad A.; Chivers, F.S.; Lorans, Roxanne; Roberts, Catherine C.; Kransdorf, Mark J.

    2014-01-01

    To re-assess the accuracy of chemical shift imaging in diagnosing indeterminate bone marrow lesions as benign or malignant. We retrospectively reviewed our experience with MR imaging of the pelvis to assess the accuracy of chemical shift imaging in distinguishing benign from malignant bone lesions. Two musculoskeletal radiologists retrospectively reviewed all osseous lesions biopsied since 2006, when chemical shift imaging was added to our routine pelvic imaging protocol. Study inclusion criteria required (1) MR imaging of an indeterminate bone marrow lesion about the pelvis and (2) subsequent histologic confirmation. The study group included 50 patients (29 male, 21 female) with an average age of 67 years (range, 41-89 years). MR imaging results were evaluated using biopsy results as the ''gold standard.'' There were 27 malignant and 23 benign lesions. Chemical shift imaging using an opposed-phase signal loss criteria of less than 20 % to indicate a malignant lesion, correctly diagnosed 27/27 malignant lesions and 14/23 benign lesions, yielding a 100 % sensitivity, 61 % specificity, 75 % PPV, 100 % NPV, and 82 % accuracy. The area under the receiver operator characteristic (ROC) curve was 0.88. The inter-rater and intra-rater agreement K values were both 1.0. Chemical shift imaging is a useful adjunct MR technique to characterize focal and diffuse marrow abnormalities on routine non-contrast pelvic imaging. It is highly sensitive in identifying malignant disease. Despite its lower specificity, the need for biopsy could be eliminated in more than 60 % of patients with benign disease. (orig.)

  11. Implications of imaging criteria for the management and treatment of intraductal papillary mucinous neoplasms - benign versus malignant findings

    Energy Technology Data Exchange (ETDEWEB)

    Walter, Thula Cannon; Steffen, Ingo G.; Stelter, Lars H.; Hamm, Bernd; Denecke, Timm; Grieser, Christian [Charite - Universitaetsmedizin Berlin, Klinik fuer Radiologie, Campus Virchow-Klinikum, Berlin (Germany); Maurer, Martin H. [Universitaetsklinik Bern, Universitaetsinstitut fuer Radiologe, Inselspital, Bern (Switzerland); Bahra, Marcus; Faber, Wladimir; Klein, Fritz [Charite - Universitaetsmedizin Berlin, Klinik fuer Allgemein-, Viszeral- und Transplantationschirurgie Campus Virchow-Klinikum, Berlin (Germany); Blaeker, Hendrik [Charite - Universitaetsmedizin Berlin, Institut fuer Pathologie, Campus Charite Mitte, Berlin (Germany)

    2015-05-01

    Evaluation of computed tomography (CT) and magnetic resonance imaging (MRI) for differentiation of pancreatic intraductal papillary mucinous neoplasm (IPMN) subtypes based on objective imaging criteria. Fifty-eight patients with 60 histologically confirmed IPMNs were included in this retrospective study. Eighty-three imaging studies (CT,n = 42; MRI,n = 41) were analysed by three independent blinded observers (O1-O3), using established imaging criteria to assess likelihood of malignancy (-5, very likely benign; 5, very likely malignant) and histological subtype (i.e., low-grade (LGD), moderate-grade (MGD), high-grade dysplasia (HGD), early invasive carcinoma (IPMC), solid carcinoma (CA) arising from IPMN). Forty-one benign (LGD IPMN,n = 20; MGD IPMN,n = 21) and 19 malignant (HGD IPMN,n = 3; IPMC,n = 6; solid CA,n = 10) IPMNs located in the main duct (n = 6), branch duct (n = 37), or both (n = 17) were evaluated. Overall accuracy of differentiation between benign and malignant IPMNs was 86/92 % (CT/MRI). Exclusion of overtly malignant cases (solid CA) resulted in overall accuracy of 83/90 % (CT/MRI). The presence of mural nodules and ductal lesion size ≥30 mm were significant indicators of malignancy (p = 0.02 and p < 0.001, respectively). Invasive IPMN can be identified with high confidence and sensitivity using CT and MRI. The diagnostic problem that remains is the accurate radiological differentiation of premalignant and non-invasive subtypes. (orig.)

  12. Social Power Increases Interoceptive Accuracy

    Directory of Open Access Journals (Sweden)

    Mehrad Moeini-Jazani

    2017-08-01

    Full Text Available Building on recent psychological research showing that power increases self-focused attention, we propose that having power increases accuracy in perception of bodily signals, a phenomenon known as interoceptive accuracy. Consistent with our proposition, participants in a high-power experimental condition outperformed those in the control and low-power conditions in the Schandry heartbeat-detection task. We demonstrate that the effect of power on interoceptive accuracy is not explained by participants’ physiological arousal, affective state, or general intention for accuracy. Rather, consistent with our reasoning that experiencing power shifts attentional resources inward, we show that the effect of power on interoceptive accuracy is dependent on individuals’ chronic tendency to focus on their internal sensations. Moreover, we demonstrate that individuals’ chronic sense of power also predicts interoceptive accuracy similar to, and independent of, how their situationally induced feeling of power does. We therefore provide further support on the relation between power and enhanced perception of bodily signals. Our findings offer a novel perspective–a psychophysiological account–on how power might affect judgments and behavior. We highlight and discuss some of these intriguing possibilities for future research.

  13. Automation of vibroacoustic data bank for random vibration criteria development. [for the space shuttle and launch vehicles

    Science.gov (United States)

    Ferebee, R. C.

    1982-01-01

    A computerized data bank system was developed for utilization of large amounts of vibration and acoustic data to formulate component random vibration design and test criteria. This system consists of a computer, graphics tablet, and a dry-silver hard copier which are all desk-top type hardware and occupy minimal space. The data bank contains data from the Saturn V and Titan III flight and static test programs. The vibration and acoustic data are stored in the form of power spectral density and one-third octave band plots over the frequency range from 20 to 2000 Hz. The data was stored by digitizing each spectral plot by tracing with the graphics tablet. The digitized data was statistically analyzed and the resulting 97.5% probability levels were stored on tape along with the appropriate structural parameters. Standard extrapolation procedures were programmed for prediction of component random vibration test criteria for new launch vehicle and payload configurations. This automated vibroacoustic data bank system greatly enhances the speed and accuracy of formulating vibration test criteria. In the future, the data bank will be expanded to include all data acquired from the space shuttle flight test program.

  14. Toxic chemical risk acceptance criteria

    International Nuclear Information System (INIS)

    Craig, D.K.; Davis, J.; Lee, L.; Lein, P.; Omberg, S.

    1992-01-01

    This paper presents recommendations of a subcommittee of the Westinghouse M ampersand 0 Nuclear Facility Safety Committee concerning toxic chemical risk acceptance criteria. Two sets of criteria have been developed, one for use in the hazard classification of facilities, and the second for use in comparing risks in DOE non-reactor nuclear facility Safety Analysis Reports. The Emergency Response Planning Guideline (ERPG) values are intended to provide estimates of concentration ranges for specific chemicals above which exposure would be expected to lead to adverse heath effects of increasing severity for ERPG-1, -2, and -3s. The subcommittee recommends that criteria for hazard class or risk range be based on ERPGs for all chemicals. Probability-based Incremental Cancer Risk (ICR) criteria are recommended for additional analyses of risks from all known or suspected human carcinogens. Criteria are given for both on-site and off-site exposure. The subcommittee also recommends that the 5-minute peak concentration be compared with the relevant criterion with no adjustment for exposure time. Since ERPGs are available for only a limited number of chemicals, the subcommittee has developed a proposed hierarchy of concentration limit parameters for the different criteria

  15. Dynamic criteria for partitioning and transmutation

    International Nuclear Information System (INIS)

    Lu, A.H.

    1991-11-01

    This paper addresses dynamic criteria intended to optimize partitioning and transmutation (P-T) concept development supporting improved nuclear waste management. Six criteria are proposed initially and the rationale for each is briefly explained. Each criterion is used as a measure (or dimension) on which the developed concepts can be evaluated. The criteria allow the P-T concepts to be evaluated in an integral system including long-term energy needs, fuel cycle, and waste management. New criteria will be identified along with the P-T concept development, and each criterion will be realistically weighted so that it is comparable in an overall criteria evaluation. The weights are subject to change as a result of technical advancements and public perception on various issues. Incomplete criteria will result in a poor choice because important factors may not be considered when the decision is made. A successful decision on the optimal P-T system depends on the completeness of criteria (dimensions) as well as realistic weights assigned to each criterion

  16. Photovoltaic system criteria documents. Volume 3: Environmental issues and evaluation criteria for photovoltaic applications

    Science.gov (United States)

    Koenig, John C.; Billitti, Joseph W.; Tallon, John M.

    1979-01-01

    The environmental issues and evaluation criteria relating to the suitability of sites proposed for photovoltaic (PV) system deployment are identified. The important issues are defined, briefly discussed and then developed into evaluation criteria. System designers are provided with information on the environmental sensitivity of PV systems in realistic applications, background material which indicates the applicability of the siting issues identified, and evaluation criteria are defined to facilitate the selection of sites that maximize PV system operation.

  17. Radiological design criteria

    International Nuclear Information System (INIS)

    Selby, J.M.; Andersen, B.V.; Carter, L.A.; Waite, D.A.

    1977-01-01

    Many new nuclear facilities are unsatisfactory from a radiation protection point of view, particularly when striving to maintain occupational exposure as low as practicable 'ALAP'. Radiation protection is achieved through physical protective features supplemented by administrative controls. Adequate physical protective feature should be achieved during construction so that supplemental administrative controls may be kept simple and workable. Many nuclear facilities fall short of adequate physical protective features, thus, remedial and sometimes awkward administrative procedures are required to safely conduct work. In reviewing the various handbooks, reports and regulations which deal with radiation protection, it may be noted that there is minimal radiological design guidance for application to nuclear facilities. A set of criteria or codes covering functional areas rather than specific nuclear facility types is badly needed. The following are suggested as functional areas to be considered: characterization of the Facility; siting and access; design exposure limits; layout (people and materials flow); ventilation and effluent control; radiation protection facilities and systems. The application of such radiological design criteria early in the design process would provide some assurance that nuclear facilities will be safe, flexible, and efficient with a minimum of costly retrofitting or administrative restrictions. Criteria which we have found helpful in these functional areas is discussed together with justification for adoption of such criteria and identification of problems which still require solution

  18. Technical Note: Evaluation of the systematic accuracy of a frameless, multiple image modality guided, linear accelerator based stereotactic radiosurgery system

    Energy Technology Data Exchange (ETDEWEB)

    Wen, N., E-mail: nwen1@hfhs.org; Snyder, K. C.; Qin, Y.; Li, H.; Siddiqui, M. S.; Chetty, I. J. [Department of Radiation Oncology, Henry Ford Health System, 2799 West Brand Boulevard, Detroit, Michigan 48202 (United States); Scheib, S. G.; Schmelzer, P. [Varian Medical System, Täfernstrasse 7, Dättwil AG 5405 (Switzerland)

    2016-05-15

    Purpose: To evaluate the total systematic accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy and intermodality difference was determined by delivering radiation to an end-to-end prototype phantom, in which the targets were localized using optical surface monitoring system (OSMS), electromagnetic beacon-based tracking (Calypso®), cone-beam CT, “snap-shot” planar x-ray imaging, and a robotic couch. Six IMRT plans with jaw tracking and a flattening filter free beam were used to study the dosimetric accuracy for intracranial and spinal stereotactic radiosurgery treatment. Results: End-to-end localization accuracy of the system evaluated with the end-to-end phantom was 0.5 ± 0.2 mm with a maximum deviation of 0.9 mm over 90 measurements (including jaw, MLC, and cone measurements for both auto and manual fusion) for single isocenter, single target treatment, 0.6 ± 0.4 mm for multitarget treatment with shared isocenter. Residual setup errors were within 0.1 mm for OSMS, and 0.3 mm for Calypso. Dosimetric evaluation based on absolute film dosimetry showed greater than 90% pass rate for all cases using a gamma criteria of 3%/1 mm. Conclusions: The authors’ experience demonstrates that the localization accuracy of the frameless image-guided system is comparable to robotic or invasive frame based radiosurgery systems.

  19. Technical Note: Evaluation of the systematic accuracy of a frameless, multiple image modality guided, linear accelerator based stereotactic radiosurgery system

    International Nuclear Information System (INIS)

    Wen, N.; Snyder, K. C.; Qin, Y.; Li, H.; Siddiqui, M. S.; Chetty, I. J.; Scheib, S. G.; Schmelzer, P.

    2016-01-01

    Purpose: To evaluate the total systematic accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy and intermodality difference was determined by delivering radiation to an end-to-end prototype phantom, in which the targets were localized using optical surface monitoring system (OSMS), electromagnetic beacon-based tracking (Calypso®), cone-beam CT, “snap-shot” planar x-ray imaging, and a robotic couch. Six IMRT plans with jaw tracking and a flattening filter free beam were used to study the dosimetric accuracy for intracranial and spinal stereotactic radiosurgery treatment. Results: End-to-end localization accuracy of the system evaluated with the end-to-end phantom was 0.5 ± 0.2 mm with a maximum deviation of 0.9 mm over 90 measurements (including jaw, MLC, and cone measurements for both auto and manual fusion) for single isocenter, single target treatment, 0.6 ± 0.4 mm for multitarget treatment with shared isocenter. Residual setup errors were within 0.1 mm for OSMS, and 0.3 mm for Calypso. Dosimetric evaluation based on absolute film dosimetry showed greater than 90% pass rate for all cases using a gamma criteria of 3%/1 mm. Conclusions: The authors’ experience demonstrates that the localization accuracy of the frameless image-guided system is comparable to robotic or invasive frame based radiosurgery systems.

  20. Sediment quality criteria: A review with recommendations for developing criteria for the Hanford Site

    Energy Technology Data Exchange (ETDEWEB)

    Driver, C.J.

    1994-05-01

    Criteria for determining the quality of liver sediment are necessary to ensure that concentrations of contaminants in aquatic systems are within acceptable limits for the protection of aquatic and human life. Such criteria should facilitate decision-making about remediation, handling, and disposal of contaminants. Several approaches to the development of sediment quality criteria (SQC) have been described and include both descriptive and numerical methods. However, no single method measures all impacts at all times to all organisms (U.S. EPA 1992b). The U.S. EPA`s interest is primarily in establishing chemically based, numerical SQC that are applicable nation-wide (Shea 1988). Of the approaches proposed for SQC development, only three are being considered for numerical SQC on a national level. These approaches include an Equilibrium Partitioning Approach, a site-specific method using bioassays (the Apparent Effects Threshold Approach), and an approach similar to EPA`s water quality criteria (Pavlou and Weston 1984). Although national (or even regional) criteria address a number of political, litigative, and engineering needs, some researchers feel that protection of benthic communities require site-specific, biologically based criteria (Baudo et al. 1990). This is particularly true for areas where complex mixtures of contaminants are present in sediments. Other scientifically valid and accepted procedures for freshwater SQC include a background concentration approach, methods using field or spiked bioassays, a screening level concentration approach, the Apparent Effects Threshold Approach, the Sediment Quality Triad, the International Joint Commission Sediment Assessment Strategy, and the National Status and Trends Program Approach. The various sediment assessment approaches are evaluated for application to the Hanford Reach and recommendations for Hanford Site sediment quality criteria are discussed.

  1. Measuring the sustainability of a natural system by using multi-criteria distance function methods: Some critical issues.

    Science.gov (United States)

    Diaz-Balteiro, L; Belavenutti, P; Ezquerro, M; González-Pachón, J; Ribeiro Nobre, S; Romero, C

    2018-05-15

    There is an important body of literature using multi-criteria distance function methods for the aggregation of a battery of sustainability indicators in order to obtain a composite index. This index is considered to be a proxy of the sustainability goodness of a natural system. Although this approach has been profusely used in the literature, it is not exempt from difficulties and potential pitfalls. Thus, in this paper, a significant number of critical issues have been identified showing different procedures capable of avoiding, or at least of mitigating, the inherent potential pitfalls associated with each one. The recommendations made in the paper could increase the theoretical soundness of the multi-criteria distance function methods when this type of approach is applied in the sustainability field, thus increasing the accuracy and realism of the sustainability measurements obtained. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Feasibility of an individual surveillance program on contamination with direct measurement methods based on the criteria established in the ICRP publication 54

    CERN Document Server

    Melandri, C

    1990-01-01

    If different methods of adequate sensitivity are available ICRP Publication 54, 'Individual Monitoring for Intakes-of Radionuclides by Workers: Design and Interpretations', recommends the use of direct measurements in individual monitoring for intakes of radionuclides. This report analyses the possibility to perform the different controls on the basis of the proposed Derived Reference Levels, respecting the accuracy requirement in evaluation of individual intake and dose. Therefore, general operative criteria are defined by analysing the potentialities and limitations of the different Whole Body Counters utilizable for the measurement with regard to the chemical, physical and metabolic characteristics of some radionuclides of particular interest in Radiation Protection. These criteria are useful for monitoring planning wherever a radiocontamination risk is possible.

  3. Diagnostic accuracy and acceptability of rapid HIV oral testing among adults attending an urban public health facility in Kampala, Uganda.

    Directory of Open Access Journals (Sweden)

    Joanita Nangendo

    Full Text Available The prevalence of HIV in Uganda is 7.3%, and yet nearly 40% of people living with HIV are unaware of their status. The current HIV testing policy which is strictly blood-based poses several challenges including: a need for high level laboratory skills, stringent waste disposal needs, and painful sample collection. It is envisaged that introduction of a rapid, painless HIV oral fluid test as a potential alternative is likely to increase the number of people testing. The aim of this study was to determine the diagnostic accuracy and acceptability of rapid HIV oral testing among adults attending Kisenyi Health Centre IV in Kampala.We conducted a cross-sectional study among 440 adults recruited consecutively at Kisenyi Health Centre IV from January to March 2016. The diagnostic accuracy of the HIV oral test was assessed by comparing to the national HIV serial testing algorithm. We also assessed for acceptability among patients and health care workers (HCWs by triangulating responses from a structured questionnaire, three focus group discussions and seven key informant interviews. Acceptability was defined as willingness to take the test at the time of the study and intention for future use of the test if it was availed. The prevalence of HIV infection among study participants was 14.8%. The HIV oral fluid test was highly accurate with sensitivity of 100% (95% CI; 94.5-100.0, specificity of 100% (95% CI; 99.0-100.0, positive predictive value (PPV of 100% (95% CI; 94.5-100.0 and negative predictive value (NPV of 100% (95% CI; 99.0-100.0. Acceptability of HIV oral testing was also high at 87.0% (95% CI; 83.6-89.9. Participants preferred HIV oral testing because it was: pain free (91%, n = 399 and did not require blood draw (82%, n = 360.The HIV oral fluid test has high diagnostic accuracy and acceptability. HIV oral testing is a suitable addition to the national HIV testing strategies with the potential of increasing access to HIV testing services in

  4. Molecular Tools for Diagnosis of Visceral Leishmaniasis: Systematic Review and Meta-Analysis of Diagnostic Test Accuracy

    Science.gov (United States)

    de Ruiter, C. M.; van der Veer, C.; Leeflang, M. M. G.; Deborggraeve, S.; Lucas, C.

    2014-01-01

    Molecular methods have been proposed as highly sensitive tools for the detection of Leishmania parasites in visceral leishmaniasis (VL) patients. Here, we evaluate the diagnostic accuracy of these tools in a meta-analysis of the published literature. The selection criteria were original studies that evaluate the sensitivities and specificities of molecular tests for diagnosis of VL, adequate classification of study participants, and the absolute numbers of true positives and negatives derivable from the data presented. Forty studies met the selection criteria, including PCR, real-time PCR, nucleic acid sequence-based amplification (NASBA), and loop-mediated isothermal amplification (LAMP). The sensitivities of the individual studies ranged from 29 to 100%, and the specificities ranged from 25 to 100%. The pooled sensitivity of PCR in whole blood was 93.1% (95% confidence interval [CI], 90.0 to 95.2), and the specificity was 95.6% (95% CI, 87.0 to 98.6). The specificity was significantly lower in consecutive studies, at 63.3% (95% CI, 53.9 to 71.8), due either to true-positive patients not being identified by parasitological methods or to the number of asymptomatic carriers in areas of endemicity. PCR for patients with HIV-VL coinfection showed high diagnostic accuracy in buffy coat and bone marrow, ranging from 93.1 to 96.9%. Molecular tools are highly sensitive assays for Leishmania detection and may contribute as an additional test in the algorithm, together with a clear clinical case definition. We observed wide variety in reference standards and study designs and now recommend consecutively designed studies. PMID:24829226

  5. Criteria for Authorship in Bioethics

    OpenAIRE

    Resnik, David B.; Master, Zubin

    2011-01-01

    Multiple authorship is becoming increasingly common in bioethics research. There are well-established criteria for authorship in empirical bioethics research but not for conceptual research. It is important to develop criteria for authorship in conceptual publications to prevent undeserved authorship and uphold standards of fairness and accountability. This article explores the issue of multiple authorship in bioethics and develops criteria for determining who should be an author on a concept...

  6. Radiation protection - Performance criteria for radiobioassay. Part 1: General principles

    International Nuclear Information System (INIS)

    2001-01-01

    International Standard ISO 12790-1 was prepared by Technical Committee ISO/TC 85, Nuclear energy, Subcommittee SC 2, Radiation protection. ISO 12790 consists of the following parts, under the general title Radiation protection - Performance criteria for radiobioassay: Part 1: General principles; and Part 2: Rationale and specific applications This part of ISO 12790 provides criteria for quality assurance and control, evaluation of performance and the accreditation of radiobioassay service laboratories. Criteria and guidance for direct radiobioassay ( in vivo) and indirect radiobioassay ( in vitro) are given in separate clauses of this part of ISO 12790. This part of ISO 12790 addresses: a) the accuracy of direct ( in vivo) measurements of activity and quantities of selected important radionuclides in test phantoms and indirect ( in vitro) measurements of activity and quantities of selected important radionuclides in test samples; b) methods for determining the minimum detectable amount; c) minimum testing levels and testing ranges; d) requirements for reporting radiobioassay results by service laboratories; e) quality assurance in service laboratories; f) quality control in service laboratories; g) protocol for reporting test evaluations by service laboratories to the testing laboratory; h) default procedures when the service laboratory customer does not specify the performance criteria. The scope of this part of ISO 12790 does not include: a) detailed radiochemical methods for separating radionuclides from biological samples; b) detailed procedures for in vivo and in vitro radioactivity measurements; c) metabolic data and mathematical models for converting radiobioassay results into absorbed dose and dose equivalent; d) procedures for the preparation and distribution of test samples and phantoms by the testing laboratories. Analytical methods for radiobioassay are not currently standardized, but are available in the literature. Guidance for converting

  7. Systematic review of discharge coding accuracy

    Science.gov (United States)

    Burns, E.M.; Rigby, E.; Mamidanna, R.; Bottle, A.; Aylin, P.; Ziprin, P.; Faiz, O.D.

    2012-01-01

    Introduction Routinely collected data sets are increasingly used for research, financial reimbursement and health service planning. High quality data are necessary for reliable analysis. This study aims to assess the published accuracy of routinely collected data sets in Great Britain. Methods Systematic searches of the EMBASE, PUBMED, OVID and Cochrane databases were performed from 1989 to present using defined search terms. Included studies were those that compared routinely collected data sets with case or operative note review and those that compared routinely collected data with clinical registries. Results Thirty-two studies were included. Twenty-five studies compared routinely collected data with case or operation notes. Seven studies compared routinely collected data with clinical registries. The overall median accuracy (routinely collected data sets versus case notes) was 83.2% (IQR: 67.3–92.1%). The median diagnostic accuracy was 80.3% (IQR: 63.3–94.1%) with a median procedure accuracy of 84.2% (IQR: 68.7–88.7%). There was considerable variation in accuracy rates between studies (50.5–97.8%). Since the 2002 introduction of Payment by Results, accuracy has improved in some respects, for example primary diagnoses accuracy has improved from 73.8% (IQR: 59.3–92.1%) to 96.0% (IQR: 89.3–96.3), P= 0.020. Conclusion Accuracy rates are improving. Current levels of reported accuracy suggest that routinely collected data are sufficiently robust to support their use for research and managerial decision-making. PMID:21795302

  8. Prediction of pre-eclampsia: a protocol for systematic reviews of test accuracy

    Directory of Open Access Journals (Sweden)

    Khan Khalid S

    2006-10-01

    Full Text Available Abstract Background Pre-eclampsia, a syndrome of hypertension and proteinuria, is a major cause of maternal and perinatal morbidity and mortality. Accurate prediction of pre-eclampsia is important, since high risk women could benefit from intensive monitoring and preventive treatment. However, decision making is currently hampered due to lack of precise and up to date comprehensive evidence summaries on estimates of risk of developing pre-eclampsia. Methods/Design A series of systematic reviews and meta-analyses will be undertaken to determine, among women in early pregnancy, the accuracy of various tests (history, examinations and investigations for predicting pre-eclampsia. We will search Medline, Embase, Cochrane Library, MEDION, citation lists of review articles and eligible primary articles and will contact experts in the field. Reviewers working independently will select studies, extract data, and assess study validity according to established criteria. Language restrictions will not be applied. Bivariate meta-analysis of sensitivity and specificity will be considered for tests whose studies allow generation of 2 × 2 tables. Discussion The results of the test accuracy reviews will be integrated with results of effectiveness reviews of preventive interventions to assess the impact of test-intervention combinations for prevention of pre-eclampsia.

  9. Saugus River and Tributaries Flood Damage Reduction Study; Lynn, Malden, Revere and Saugus, Massachusetts. Section 2. Final Environmental Impact Statement and Final Environmental Impact Report

    Science.gov (United States)

    1989-12-01

    sensitive marine aquatic life although the less stringent acute criteria were usually met. Mercury appears to exceed the chronic criteria frequently while...other metals showing occasional exceedances include copper, zinc, lead, chromium and nickel. Acute criteria is also occasionally exceeded by copper. b...Main Report A- ppendices Sea Level Rise Chapter 8 P. 14 A-C,G,H Secondary & Cumulative Para. 7.206 Impacts Section 404(b)(1) After EIS/EIR Evaluation

  10. Validation of the Gambling Disorder Screening Questionnaire, a self-administered diagnostic questionnaire for gambling disorder based on the DSM-5 criteria.

    Science.gov (United States)

    Villella, Corrado; Pascucci, Marco; de Waure, Chiara; Bellomo, Antonello; Conte, Gianluigi

    2016-01-01

    The DSM-5 has modified the diagnostic criteria for gambling disorder, compared to the fourth edition of the manual; new diagnostic instruments are therefore needed. This study evaluated the psychometric characteristics of the Gambling Disorder Screening Questionnaire (GDSQ), a self-report questionnaire based on the DSM-IV and DSM-5 criteria for Gambling Disorder, measuring its validity, internal consistency, and submitting the questionnaire to a principal components analysis. 71 patients from a gambling disorder outpatient clinic and 70 controls were evaluated with the GDSQ, the South Oaks Gambling Screen (SOGS), and a psychiatric interview. The test showed a good sensibility, specificity, internal consistency, concurrent validity with the SOGS. The exclusion of the “illegal acts” item, and the lowering of the cut-off score to four positive items, as suggested by the DSM-5 criteria, improved the test sensibility and internal consistency. The GDSQ can be considered a useful screening test for Gambling Disorder. Furthermore, this study confirms the improved diagnostic accuracy of the criteria listed in the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders, compared to the previous edition.

  11. The Assessment of Quality, Accuracy, and Readability of Online Educational Resources for Platelet-Rich Plasma.

    Science.gov (United States)

    Ghodasra, Jason H; Wang, Dean; Jayakar, Rohit G; Jensen, Andrew R; Yamaguchi, Kent T; Hegde, Vishal V; Jones, Kristofer J

    2018-01-01

    To critically evaluate the quality, accuracy, and readability of readily available Internet patient resources for platelet-rich plasma (PRP) as a treatment modality for musculoskeletal injuries. Using the 3 most commonly used Internet search engines (Google, Bing, Yahoo), the search term "platelet rich plasma" was entered, and the first 50 websites from each search were reviewed. The website's affiliation was identified. Quality was evaluated using 25-point criteria based on guidelines published by the American Academy of Orthopaedic Surgeons, and accuracy was assessed with a previously described 12-point grading system by 3 reviewers independently. Readability was evaluated using the Flesch-Kincaid (FK) grade score. A total of 46 unique websites were identified and evaluated. The average quality and accuracy was 9.4 ± 3.4 (maximum 25) and 7.9 ± 2.3 (maximum 12), respectively. The average FK grade level was 12.6 ± 2.4, which is several grades higher than the recommended eighth-grade level for patient education material. Ninety-one percent (42/46) of websites were authored by physicians, and 9% (4/46) contained commercial bias. Mean quality was significantly greater in websites authored by health care providers (9.8 ± 3.1 vs 5.9 ± 4.7, P = .029) and in websites without commercial bias (9.9 ± 3.1 vs 4.5 ± 3.2, P = .002). Mean accuracy was significantly lower in websites authored by health care providers (7.6 ± 2.2 vs 11.0 ± 1.2, P = .004). Only 24% (11/46) reported that PRP remains an investigational treatment. The accuracy and quality of online patient resources for PRP are poor, and the information overestimates the reading ability of the general population. Websites authored by health care providers had higher quality but lower accuracy. Additionally, the majority of websites do not identify PRP as an experimental treatment, which may fail to provide appropriate patient understanding and expectations. Physicians should educate patients that many online

  12. Accuracy of the Spot and Plusoptix photoscreeners for detection of astigmatism.

    Science.gov (United States)

    Crescioni, Mabel; Miller, Joseph M; Harvey, Erin M

    2015-10-01

    To evaluate the accuracy of the Spot (V2.0.16) and Plusoptix S12 (ROC4, V6.1.4.0) photoscreeners in detecting astigmatism meeting AAPOS referral criteria in students from a population with high prevalence of astigmatism. Students attending grades 3-8 on the Tohono O'odham reservation were examined. Screening was attempted with both the Spot and Plusoptix photoscreeners. Results were compared to cycloplegic refraction. Screening attempts providing no estimate of refractive error were considered fail/refer. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for detection of refractive errors were determined using AAPOS referral criteria and receiver operating characteristic area under the curve (ROC AUC) analysis was conducted for measures of astigmatism. Agreement between screening and cycloplegic refraction measurements of astigmatism, spherical equivalent, and anisometropia were assessed using t tests and correlation analyses. A total of 209 students were included. Of the total, 116 (55%) met examination-positive criteria based on cycloplegic refraction, with 105 of those (90%) meeting the criterion for astigmatism. Measurements success rates were 97% for Spot and 54% for Plusoptix. Comparing the Spot and the Plusoptix, sensitivity was 96% versus 100%, specificity was 87% versus 61%, PPV was 90% versus 76%, and NPV was 94% versus 100% for detection of refractive error. Both screeners overestimated astigmatism by 1/3 D to 2/3 D. AUC for astigmatism was 0.97 for Spot and 0.83 for Plusoptix. In this highly astigmatic population, the Spot and the Plusoptix had similar sensitivity, but the Spot had better specificity and measurement success rates. Compared with results from study samples with lower rates of astigmatism, our results highlight the need to assess the ability of screening instruments to detect individual types of refractive errors. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus

  13. Data accuracy assessment using enterprise architecture

    Science.gov (United States)

    Närman, Per; Holm, Hannes; Johnson, Pontus; König, Johan; Chenine, Moustafa; Ekstedt, Mathias

    2011-02-01

    Errors in business processes result in poor data accuracy. This article proposes an architecture analysis method which utilises ArchiMate and the Probabilistic Relational Model formalism to model and analyse data accuracy. Since the resources available for architecture analysis are usually quite scarce, the method advocates interviews as the primary data collection technique. A case study demonstrates that the method yields correct data accuracy estimates and is more resource-efficient than a competing sampling-based data accuracy estimation method.

  14. National Recommended Water Quality Criteria

    Data.gov (United States)

    U.S. Environmental Protection Agency — The National Recommended Water Quality Criteria is a compilation of national recommended water quality criteria for the protection of aquatic life and human health...

  15. Water quality criteria for lead

    Energy Technology Data Exchange (ETDEWEB)

    Nagpal, N.K.

    1987-01-01

    This report is one in a series that establishes water quality criteria for British Columbia. The report sets criteria for lead to protect a number of water uses, including drinking water, freshwater and marine aquatic life, wildlife, livestock, irrigation, and recreation. The criteria are set as either maximum concentrations of total lead that should not be exceeded at any time, or average concentrations that should not be exceeded over a 30-day period. Actual values are summarized.

  16. 46 CFR 385.51 - Criteria: Projects.

    Science.gov (United States)

    2010-10-01

    ... results; (iii) The extent of the problems treated and whether the objectives sought by the undertaking are... MARITIME ADMINISTRATION, DEPARTMENT OF TRANSPORTATION MISCELLANEOUS RESEARCH AND DEVELOPMENT GRANT AND COOPERATIVE AGREEMENTS REGULATIONS Criteria for Award § 385.51 Criteria: Projects. The criteria to be used by...

  17. Criteria for saturated magnetization loop

    International Nuclear Information System (INIS)

    Harres, A.; Mikhov, M.; Skumryev, V.; Andrade, A.M.H. de; Schmidt, J.E.; Geshev, J.

    2016-01-01

    Proper estimation of magnetization curve parameters is vital in studying magnetic systems. In the present article, criteria for discrimination non-saturated (minor) from saturated (major) hysteresis loops are proposed. These employ the analysis of (i) derivatives of both ascending and descending branches of the loop, (ii) remanent magnetization curves, and (iii) thermomagnetic curves. Computational simulations are used in order to demonstrate their validity. Examples illustrating the applicability of these criteria to well-known real systems, namely Fe_3O_4 and Ni fine particles, are provided. We demonstrate that the anisotropy-field value estimated from a visual examination of an only apparently major hysteresis loop could be more than two times lower than the real one. - Highlights: • Proper estimation of hysteresis-loop parameters is vital in magnetic studies. • We propose criteria for discrimination minor from major hysteresis loops. • The criteria analyze magnetization, remanence and ZFC/FC curves and/or their derivatives. • Examples of their application on real nanoparticles systems are given. • Using the criteria could avoid twofold or bigger saturation-field underestimation errors.

  18. Criteria for saturated magnetization loop

    Energy Technology Data Exchange (ETDEWEB)

    Harres, A. [Departamento de Física, UFSM, Santa Maria, 97105-900 Rio Grande do Sul (Brazil); Mikhov, M. [Faculty of Physics, University of Sofia, 1164 Sofia (Bulgaria); Skumryev, V. [Institució Catalana de Recerca i Estudis Avançats, 08010 Barcelona (Spain); Departament de Física, Universitat Autònoma de Barcelona, 08193 Barcelona (Spain); Andrade, A.M.H. de; Schmidt, J.E. [Instituto de Física, UFRGS, Porto Alegre, 91501-970 Rio Grande do Sul (Brazil); Geshev, J., E-mail: julian@if.ufrgs.br [Departament de Física, Universitat Autònoma de Barcelona, 08193 Barcelona (Spain); Instituto de Física, UFRGS, Porto Alegre, 91501-970 Rio Grande do Sul (Brazil)

    2016-03-15

    Proper estimation of magnetization curve parameters is vital in studying magnetic systems. In the present article, criteria for discrimination non-saturated (minor) from saturated (major) hysteresis loops are proposed. These employ the analysis of (i) derivatives of both ascending and descending branches of the loop, (ii) remanent magnetization curves, and (iii) thermomagnetic curves. Computational simulations are used in order to demonstrate their validity. Examples illustrating the applicability of these criteria to well-known real systems, namely Fe{sub 3}O{sub 4} and Ni fine particles, are provided. We demonstrate that the anisotropy-field value estimated from a visual examination of an only apparently major hysteresis loop could be more than two times lower than the real one. - Highlights: • Proper estimation of hysteresis-loop parameters is vital in magnetic studies. • We propose criteria for discrimination minor from major hysteresis loops. • The criteria analyze magnetization, remanence and ZFC/FC curves and/or their derivatives. • Examples of their application on real nanoparticles systems are given. • Using the criteria could avoid twofold or bigger saturation-field underestimation errors.

  19. 45 CFR 1176.3 - Criteria.

    Science.gov (United States)

    2010-10-01

    ... ENDOWMENT FOR THE HUMANITIES PART-TIME CAREER EMPLOYMENT § 1176.3 Criteria. Positions becoming vacant... to part-time. Among the criteria which may be used when conducting this review are: (a) Mission...

  20. Diagnostic Accuracy of Cone-beam Computed Tomography and Conventional Radiography on Apical Periodontitis: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Leonardi Dutra, Kamile; Haas, Letícia; Porporatti, André Luís; Flores-Mir, Carlos; Nascimento Santos, Juliana; Mezzomo, Luis André; Corrêa, Márcio; De Luca Canto, Graziela

    2016-03-01

    Endodontic diagnosis depends on accurate radiographic examination. Assessment of the location and extent of apical periodontitis (AP) can influence treatment planning and subsequent treatment outcomes. Therefore, this systematic review and meta-analysis assessed the diagnostic accuracy of conventional radiography and cone-beam computed tomographic (CBCT) imaging on the discrimination of AP from no lesion. Eight electronic databases with no language or time limitations were searched. Articles in which the primary objective was to evaluate the accuracy (sensitivity and specificity) of any type of radiographic technique to assess AP in humans were selected. The gold standard was the histologic examination for actual AP (in vivo) or in situ visualization of bone defects for induced artificial AP (in vitro). Accuracy measurements described in the studies were transformed to construct receiver operating characteristic curves and forest plots with the aid of Review Manager v.5.2 (The Nordic Cochrane Centre, Copenhagen, Denmark) and MetaDisc v.1.4. software (Unit of Clinical Biostatistics Team of the Ramón y Cajal Hospital, Madrid, Spain). The methodology of the selected studies was evaluated using the Quality Assessment Tool for Diagnostic Accuracy Studies-2. Only 9 studies met the inclusion criteria and were subjected to a qualitative analysis. A meta-analysis was conducted on 6 of these articles. All of these articles studied artificial AP with induced bone defects. The accuracy values (area under the curve) were 0.96 for CBCT imaging, 0.73 for conventional periapical radiography, and 0.72 for digital periapical radiography. No evidence was found for panoramic radiography. Periapical radiographs (digital and conventional) reported good diagnostic accuracy on the discrimination of artificial AP from no lesions, whereas CBCT imaging showed excellent accuracy values. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  1. 10 CFR 905.36 - Marketing criteria.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Marketing criteria. 905.36 Section 905.36 Energy DEPARTMENT OF ENERGY ENERGY PLANNING AND MANAGEMENT PROGRAM Power Marketing Initiative § 905.36 Marketing criteria. Western shall retain applicable provisions of existing marketing criteria for projects where...

  2. User-Centric Multi-Criteria Information Retrieval

    Science.gov (United States)

    Wolfe, Shawn R.; Zhang, Yi

    2009-01-01

    Information retrieval models usually represent content only, and not other considerations, such as authority, cost, and recency. How could multiple criteria be utilized in information retrieval, and how would it affect the results? In our experiments, using multiple user-centric criteria always produced better results than a single criteria.

  3. STTR Phase I: Low-Cost, High-Accuracy, Whole-Building Carbon Dioxide Monitoring for Demand Control Ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Hallstrom, Jason; Ni, Zheng Richard

    2018-05-15

    This STTR Phase I project assessed the feasibility of a new CO2 sensing system optimized for low-cost, high-accuracy, whole-building monitoring for use in demand control ventilation. The focus was on the development of a wireless networking platform and associated firmware to provide signal conditioning and conversion, fault- and disruptiontolerant networking, and multi-hop routing at building scales to avoid wiring costs. Early exploration of a bridge (or “gateway”) to direct digital control services was also explored. Results of the project contributed to an improved understanding of a new electrochemical sensor for monitoring indoor CO2 concentrations, as well as the electronics and networking infrastructure required to deploy those sensors at building scales. New knowledge was acquired concerning the sensor’s accuracy, environmental response, and failure modes, and the acquisition electronics required to achieve accuracy over a wide range of CO2 concentrations. The project demonstrated that the new sensor offers repeatable correspondence with commercial optical sensors, with supporting electronics that offer gain accuracy within 0.5%, and acquisition accuracy within 1.5% across three orders of magnitude variation in generated current. Considering production, installation, and maintenance costs, the technology presents a foundation for achieving whole-building CO2 sensing at a price point below $0.066 / sq-ft – meeting economic feasibility criteria established by the Department of Energy. The technology developed under this award addresses obstacles on the critical path to enabling whole-building CO2 sensing and demand control ventilation in commercial retrofits, small commercial buildings, residential complexes, and other highpotential structures that have been slow to adopt these technologies. It presents an opportunity to significantly reduce energy use throughout the United States a

  4. Improving shuffler assay accuracy

    International Nuclear Information System (INIS)

    Rinard, P.M.

    1995-01-01

    Drums of uranium waste should be disposed of in an economical and environmentally sound manner. The most accurate possible assays of the uranium masses in the drums are required for proper disposal. The accuracies of assays from a shuffler are affected by the type of matrix material in the drums. Non-hydrogenous matrices have little effect on neutron transport and accuracies are very good. If self-shielding is known to be a minor problem, good accuracies are also obtained with hydrogenous matrices when a polyethylene sleeve is placed around the drums. But for those cases where self-shielding may be a problem, matrices are hydrogenous, and uranium distributions are non-uniform throughout the drums, the accuracies are degraded. They can be greatly improved by determining the distributions of the uranium and then applying correction factors based on the distributions. This paper describes a technique for determining uranium distributions by using the neutron count rates in detector banks around the waste drum and solving a set of overdetermined linear equations. Other approaches were studied to determine the distributions and are described briefly. Implementation of this correction is anticipated on an existing shuffler next year

  5. A proposal for combined MRI and PET/CT interpretation criteria for preoperative nodal staging in non-small-cell lung cancer

    International Nuclear Information System (INIS)

    Kim, Yoo Na; Yi, Chin A.; Lee, Kyung Soo; Lee, Ho Yun; Kim, Tae Sung; Chung, Myung Jin; Kwon, O.Jung; Chung, Man Pyo; Kim, Byung-Tae; Choi, Joon Young; Kim, Seon Woo; Han, Joungho; Shim, Young Mog

    2012-01-01

    To determine the positive reading criteria for malignant nodes when interpreting combined MRI and PET/CT images for preoperative nodal staging in non-small-cell lung cancer (NSCLC). Forty-nine patients with biopsy-proven NSCLC underwent both PET/CT and thoracic MRI [diffusion weighted imaging (DWI)]. Each nodal station was evaluated for the presence of metastasis by applying either inclusive (positive if either one read positive) or exclusive (positive if both read positive) criteria in the combined interpretation of PET/CT and MRI. Nodal stage was confirmed pathologically. The combined diagnostic accuracy of PET/CT and MRI was determined on per-nodal station and per-patient bases and compared with that of PET/CT alone. In 49 patients, 39 (19%) of 206 nodal stations harboured malignant cells. Out of 206 nodal stations, 186 (90%) had concordant readings, while the rest (10%) had discordant readings. Inclusive criteria of combined PET/CT and MRI helped increase sensitivity for detecting nodal metastasis (69%) compared with PET/CT alone (46%; P = 0.003), while specificity was not significantly decreased. Inclusive criteria in combined MRI and PET/CT readings help improve significantly the sensitivity for detecting nodal metastasis compared with PET/CT alone and may decrease unnecessary open thoracotomy. (orig.)

  6. Criteria for operator review of workplace changes

    International Nuclear Information System (INIS)

    Davey, E.

    2000-01-01

    A set of criteria for reviewing workplace changes has been developed for use by plant Operations staff. The criteria were developed to provide Operations staff with a practical framework for structuring assessments and subsequent review comments with regard to control room modifications and innovations that impact their work environment. The criteria were assembled from design, operations and human factors engineering principles, and system review experiences with plant Operations staff over the past ten years. Operations staff at several CANDU stations helped shape the emphasis for initial criteria definition and have assisted with criteria refinement through trial applications. Use of the criteria is expected to lead to more effective and task relevant equipment evaluations by Operations staff, and ultimately lead to system modifications and innovations that better serve plant operation needs. The paper begins with a discussion of the rationale for criteria development and the attributes of 'good' design. The balance of the paper outlines the project objectives, describes the approach applied in assembling, structuring, and refining the review criteria, and illustrates the application of the criteria in the review of a proposed control room innovation. (author)

  7. Comparison of UK and US screening criteria for detection of retinopathy of prematurity in a developing nation.

    Science.gov (United States)

    Ugurbas, Silay Canturk; Gulcan, Hande; Canan, Handan; Ankarali, Handan; Torer, Birgin; Akova, Yonca Aydın

    2010-12-01

    To determine the incidence, risk factors, and appropriateness of differing guidelines in developed nations for screening for retinopathy of prematurity (ROP) in a single nursery in a large urban city in southern Turkey. The records of 260 premature infants born ≤34 weeks in a single tertiary unit were retrospectively reviewed for ROP risk factors and diagnosis. Applicability of UK and US criteria were assessed by the use of receiver operating characteristic curves. ROP of any stage was present in 60 infants (23%); ROP requiring treatment was seen in 30 (11.5%). Univariate analysis showed a significant relationship among the following factors: gestational age, birth weight, total duration of supplemental oxygen, duration of mechanical ventilation, respiratory distress syndrome, anemia, and intraventricular hemorrhage (p < 0.0001). Multiple logistic regression analysis showed gestational age (p = 0.039), birth weight (p = 0.05), respiratory distress syndrome (p = 0.05), and anemia (p = 0.004) as independent predictors of ROP requiring treatment. Area under curve for gestational age alone for diagnosing stage 2 or greater ROP was 0.824 ± 0.03 (p = 0.0001) and for birth weight alone was 0.808 ± 0.03 (p = 0.0001). UK screening criteria detected all stage 2 and greater ROP; US screening criteria missed 2 infants with stage 2 ROP but detected all treatment-requiring disease. Adoption of these screening criteria would have reduced unnecessary examinations by either 21% (UK) or 37% (US). UK and US criteria improved the detection accuracy for ROP requiring treatment in Turkey and should be studied for other developing nations. Copyright © 2010 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  8. Quality criteria for chest X-ray image

    International Nuclear Information System (INIS)

    Krieg, R.

    1985-01-01

    A distinction has to be made between invariable and variable criteria in the determination of chest X-ray picture quality criteria. The invariable criteria are defined by the properties of the object and the psychophysiological laws of perception and cognition, and the variable criteria are determined by the prevailing state of the art of technology. An agreement on these criteria is based on the knowledge of the nature and the technical conditions of X-ray picture production and reproduction. The slogan 'the best picture at the lowest dose' dominates, too, the discussion centering around the X-ray picture of the chest, its quality and criteria. (orig./MG) [de

  9. The accuracy of home glucose meters in hypoglycemia.

    Science.gov (United States)

    Sonmez, Alper; Yilmaz, Zeynep; Uckaya, Gokhan; Kilic, Selim; Tapan, Serkan; Taslipinar, Abdullah; Aydogdu, Aydogan; Yazici, Mahmut; Yilmaz, Mahmut Ilker; Serdar, Muhittin; Erbil, M Kemal; Kutlu, Mustafa

    2010-08-01

    Home glucose meters (HGMs) may not be accurate enough to sense hypoglycemia. We evaluated the accuracy and the capillary and venous comparability of five different HGMs (Optium Xceed [Abbott Diabetes Care, Alameda, CA, USA], Contour TS [Bayer Diabetes Care, Basel, Switzerland], Accu-Chek Go [Roche Ltd., Basel, Switzerland], OneTouch Select [Lifescan, Milpitas, CA, USA], and EZ Smart [Tyson Bioresearch Inc., Chu-Nan, Taiwan]) in an adult population. The insulin hypoglycemia test was performed to 59 subjects (56 males; 23.6 +/- 3.2 years old). Glucose was measured from forearm venous blood and finger capillary samples both before and after regular insulin (0.1 U/kg) was injected. Venous samples were analyzed in the reference laboratory by the hexokinase method. In vitro tests for method comparison and precision analyses were also performed by spiking the glucose-depleted venous blood. All HGMs failed to sense hypoglycemia to some extend. EZ Smart was significantly inferior in critical error Zone D, and OneTouch Select was significantly inferior in the clinically unimportant error Zone B. Accu-Chek Go, Optium Xceed, and Contour TS had similar performances and were significantly better than the other two HGMs according to error grid analysis or International Organization for Standardization criteria. The in vitro tests were consistent with the above clinical data. The capillary and venous consistencies of Accu-Chek Go and OneTouch Select were better than the other HGMs. The present results show that not all the HGMs are accurate enough in low blood glucose levels. The patients and the caregivers should be aware of these restrictions of the HGMs and give more credit to the symptoms of hypoglycemia than the values obtained by the HGMs. Finally, these results indicate that there is a need for the revision of the accuracy standards of HGMs in low blood glucose levels.

  10. CCS site characterisation criteria

    Energy Technology Data Exchange (ETDEWEB)

    Bachu, S.; Hawkes, C.; Lawton, D.; Pooladi-Darvish, M.; Perkins, E.

    2009-12-15

    IEA GHG recently commissioned the Alberta Research Counil in Canada to conduct a review of storage site selection criteria and site characterisation methods in order to produce a synthesis report. This report reviews the literature on the subject on the site seleciton and characterisation since the publication of the IPCC Special Report on CCS, and provides a synthesis and classification of criteria. 161 refs.

  11. Risk assessment of soil contamination criteria

    International Nuclear Information System (INIS)

    King, C.M.; Marter, W.L.; Montaque, D.F.; Holton, G.A.

    1987-06-01

    Criteria have been developed to select radioactive and nonradioactive contaminants at waste sites detailed analysis and risk assessment. These criteria were based on soil and water quality guidelines developed by various government agencies to determine if the criteria were appropriate. We performed a risk assessment of a hypothetical site which contained radioactive and nonradioactive contaminants at levels equal to the criteria values. Risks to the public from atmospheric, surface water, and groundwater exposure pathways were examined. Health risks to the public from atmospheric releases of radioactive and nonradioactive materials from a waste at soil criteria contamination levels are low. Health risks to the maximally exposed individual to chemical carcinogens are considerably below traditional EPA action levels. And health risks to the maximally exposed individual to atmospherically released radioactive contaminants is 1.88 x 10 -7 , more than a factor of 5 less than 10 -6 . Based on our atmospheric exposure pathways analysis and risk assessment, the applied soil criteria are appropriate for screening out unimportant risk contributors to human health from atmospheric exposure pathways. 13 refs., 3 figs., 7 tabs

  12. Accuracy of the Estimated Core Temperature (ECTemp) Algorithm in Estimating Circadian Rhythm Indicators

    Science.gov (United States)

    2017-04-12

    measurement of CT outside of stringent laboratory environments. This study evaluated ECTempTM, a heart rate- based extended Kalman Filter CT...were lower than heart-rate based models analyzed in previous studies. As such, ECTempTM demonstrates strong potential for estimating circadian CT...control of heat transfer from the core to the extremities [11]. As such, heart rate plays a pivotal role in thermoregulation as a primary

  13. NSSS supplier's response to differing safety criteria

    Energy Technology Data Exchange (ETDEWEB)

    Cremades, J; Filkin, R; Franke, T [Westinghouse Electric Nuclear Energy Systems Europe (WENESE), Brussels (Belgium)

    1980-11-01

    The limited progress achieved to date in harmonizing national criteria has led to the development of designs which include the most common national requirements. Progress towards harmonization of safety criteria can be accelerated by expanding the IAEA leadership and co-ordination activities, and implementing an integrated approach to criteria development. National and International safety criteria are examined.

  14. Proposed diagnostic criteria for internet addiction.

    Science.gov (United States)

    Tao, Ran; Huang, Xiuqin; Wang, Jinan; Zhang, Huimin; Zhang, Ying; Li, Mengchen

    2010-03-01

    The objective of this study was to develop diagnostic criteria for internet addiction disorder (IAD) and to evaluate the validity of our proposed diagnostic criteria for discriminating non-dependent from dependent internet use in the general population. This study was conducted in three stages: the developmental stage (110 subjects in the survey group; 408 subjects in the training group), where items of the proposed diagnostic criteria were developed and tested; the validation stage (n = 405), where the proposed criteria were evaluated for criterion-related validity; and the clinical stage (n = 150), where the criteria and the global clinical impression of IAD were evaluated by more than one psychiatrist to determine inter-rater reliability. The proposed internet addiction diagnostic criteria consisted of symptom criterion (seven clinical symptoms of IAD), clinically significant impairment criterion (functional and psychosocial impairments), course criterion (duration of addiction lasting at least 3 months, with at least 6 hours of non-essential internet usage per day) and exclusion criterion (exclusion of dependency attributed to psychotic disorders). A diagnostic score of 2 + 1, where the first two symptoms (preoccupation and withdrawal symptoms) and at least one of the five other symptoms (tolerance, lack of control, continued excessive use despite knowledge of negative effects/affects, loss of interests excluding internet, and use of the internet to escape or relieve a dysphoric mood) was established. Inter-rater reliability was 98%. Our findings suggest that the proposed diagnostic criteria may be useful for the standardization of diagnostic criteria for IAD.

  15. Potentially inappropriate prescribing in institutionalised older patients in Spain: the STOPP-START criteria compared with the Beers criteria

    Directory of Open Access Journals (Sweden)

    Bonet M

    2012-06-01

    Full Text Available Objective: The aims of this study were to identify potentially inappropriate prescribing using the Beers and STOPP criteria. The START criteria were applied to detect prescription omission in the geriatric population. We compared the utility of these criteria in institutionalised older people.Methods: Descriptive study reviewing the medication and clinical records of 81 residents (aged 65 years and more by pharmacists in a nursing home in the Lleida region (Spain.Results: The mean patients’ age was 84 (SD=8 years, with an average of 5 drugs per resident (total prescriptions: 416 medicines. The Beers criteria identified potentially inappropriate medication use in 25% of patients and 48% of patients used at least 1 inappropriate medication according to STOPP criteria. The most frequent potentially inappropriate medications for both criteria were long-acting benzodiazepines and NSAIDs. START detected 58 potential prescribing omissions in 44% of patients. Calcium-vitamin D supplementation in osteoporosis was the most frequent rule (15%, but omissions corresponding to the cardiovascular system implied 23% of patients.Conclusion: The STOPP-START criteria reveal that potentially inappropriate prescribing (PIP is a highly prevalent problem among Spanish nursing home residents, and a statistically significant positive correlation was found between the number of medicines prescribed and the number of PIP detected in this study. The STOPP criteria detect a larger number of PI medications in this geriatric population than the Beers criteria. The prescribing omissions detected by the START criteria are relevant and require intervention. Pharmacists’ review of medications may help identify potentially inappropriate prescribing and, through an interdisciplinary approach, working with physicians may improve prescribing practices among geriatric residents of nursing homes.

  16. Molecular tools for diagnosis of visceral leishmaniasis: systematic review and meta-analysis of diagnostic test accuracy.

    Science.gov (United States)

    de Ruiter, C M; van der Veer, C; Leeflang, M M G; Deborggraeve, S; Lucas, C; Adams, E R

    2014-09-01

    Molecular methods have been proposed as highly sensitive tools for the detection of Leishmania parasites in visceral leishmaniasis (VL) patients. Here, we evaluate the diagnostic accuracy of these tools in a meta-analysis of the published literature. The selection criteria were original studies that evaluate the sensitivities and specificities of molecular tests for diagnosis of VL, adequate classification of study participants, and the absolute numbers of true positives and negatives derivable from the data presented. Forty studies met the selection criteria, including PCR, real-time PCR, nucleic acid sequence-based amplification (NASBA), and loop-mediated isothermal amplification (LAMP). The sensitivities of the individual studies ranged from 29 to 100%, and the specificities ranged from 25 to 100%. The pooled sensitivity of PCR in whole blood was 93.1% (95% confidence interval [CI], 90.0 to 95.2), and the specificity was 95.6% (95% CI, 87.0 to 98.6). The specificity was significantly lower in consecutive studies, at 63.3% (95% CI, 53.9 to 71.8), due either to true-positive patients not being identified by parasitological methods or to the number of asymptomatic carriers in areas of endemicity. PCR for patients with HIV-VL coinfection showed high diagnostic accuracy in buffy coat and bone marrow, ranging from 93.1 to 96.9%. Molecular tools are highly sensitive assays for Leishmania detection and may contribute as an additional test in the algorithm, together with a clear clinical case definition. We observed wide variety in reference standards and study designs and now recommend consecutively designed studies. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  17. Axis I psychiatric diagnoses in adolescents and young adults with 22q11 deletion syndrome

    Science.gov (United States)

    Ousley, O.Y.; Smearman, E.; Fernandez-Carriba, S.; Rockers, K.A.; Coleman, K.; Walker, E.F.; Cubells, J.F.

    2017-01-01

    Background 22q11.2 deletion syndrome (22q11DS) associates with schizophrenia spectrum disorders (SSDs), autism spectrum disorders (ASDs), and other psychiatric disorders, but co-occurrence of diagnoses are not well described. Methods We evaluated the co-occurrence of SSDs, ASDs and other axis I psychiatric diagnoses in 31 adolescents and adults with 22q11DS, assessing ASDs using either stringent Collaborative Program for Excellence in Autism (ASD-CPEA) criteria, or less stringent DSM-IV criteria alone (ASD-DSM-IV). Results Ten (32%) individuals met criteria for an SSD, five (16%) for ASD-CPEA, and five others (16%) for ASD-DSM-IV. Of those with ASD-CPEA, one (20%) met SSD criteria. Of those with ASD-DSM-IV, four (80%) met SSD criteria. Depressive disorders (8 individuals; 26%) and anxiety disorders (7; 23%) sometimes co-occurred with SSDs and ASDs. SSDs, ASDs, and anxiety occurred predominantly among males and depression predominantly among females. Conclusions Individuals with 22q11DS can manifest SSDs in the presence or absence of ASDs and other axis I diagnoses. The results suggest that standard clinical care should include childhood screening for ASDs, and later periodic screening for all axis I diagnoses. PMID:23916466

  18. Performance of the 2012 Systemic Lupus International Collaborating Clinics classification criteria versus the 1997 American College of Rheumatology classification criteria in adult and juvenile systemic lupus erythematosus. A systematic review and meta-analysis.

    Science.gov (United States)

    Hartman, Esther A R; van Royen-Kerkhof, Annet; Jacobs, Johannes W G; Welsing, Paco M J; Fritsch-Stork, Ruth D E

    2018-03-01

    To evaluate the performance in classifying systemic lupus erythematosus by the 2012 Systemic Lupus International Collaborating Clinics criteria (SLICC'12), versus the revised American College of Rheumatology criteria from 1997 (ACR'97) in adult and juvenile SLE patients. A systematic literature search was conducted in PubMed and Embase for studies comparing SLICC'12 and ACR'97 with clinical diagnosis. A meta-analysis was performed to estimate the sensitivity and specificity of SLICC'12 and ACR'97. To assess classification earlier in the disease by either set, sensitivity and specificity were compared for patients with disease duration <5years. Sensitivity and specificity of individual criteria items were also assessed. In adult SLE (nine studies: 5236 patients, 1313 controls), SLICC'12 has higher sensitivity (94.6% vs. 89.6%) and similar specificity (95.5% vs. 98.1%) compared to ACR'97. For juvenile SLE (four studies: 568 patients, 339 controls), SLICC'12 demonstrates higher sensitivity (99.9% vs. 84.3%) than ACR'97, but much lower specificity (82.0% vs. 94.1%). SLICC'12 classifies juvenile SLE patients earlier in disease course. Individual items contributing to diagnostic accuracy are low complement, anti-ds DNA and acute cutaneous lupus in SLICC'12, and the immunologic and hematologic disorder in ACR'97. Based on sensitivity and specificity SLICC'12 is best for adult SLE. Following the view that higher specificity, i.e. avoidance of false positives, is preferable, ACR'97 is best for juvenile SLE even if associated with lower sensitivity. Our results on the contribution of the individual items of SLICC'12 and ACR´97 may be of value in future efforts to update classification criteria. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Geoid undulation accuracy

    Science.gov (United States)

    Rapp, Richard H.

    1993-01-01

    The determination of the geoid and equipotential surface of the Earth's gravity field, has long been of interest to geodesists and oceanographers. The geoid provides a surface to which the actual ocean surface can be compared with the differences implying information on the circulation patterns of the oceans. For use in oceanographic applications the geoid is ideally needed to a high accuracy and to a high resolution. There are applications that require geoid undulation information to an accuracy of +/- 10 cm with a resolution of 50 km. We are far from this goal today but substantial improvement in geoid determination has been made. In 1979 the cumulative geoid undulation error to spherical harmonic degree 20 was +/- 1.4 m for the GEM10 potential coefficient model. Today the corresponding value has been reduced to +/- 25 cm for GEM-T3 or +/- 11 cm for the OSU91A model. Similar improvements are noted by harmonic degree (wave-length) and in resolution. Potential coefficient models now exist to degree 360 based on a combination of data types. This paper discusses the accuracy changes that have taken place in the past 12 years in the determination of geoid undulations.

  20. Improving plasma shaping accuracy through consolidation of control model maintenance, diagnostic calibration, and hardware change control

    International Nuclear Information System (INIS)

    Baggest, D.S.; Rothweil, D.A.; Pang, S.

    1995-12-01

    With the advent of more sophisticated techniques for control of tokamak plasmas comes the requirement for increasingly more accurate models of plasma processes and tokamak systems. Development of accurate models for DIII-D power systems, vessel, and poloidal coils is already complete, while work continues in development of general plasma response modeling techniques. Increased accuracy in estimates of parameters to be controlled is also required. It is important to ensure that errors in supporting systems such as diagnostic and command circuits do not limit the accuracy of plasma parameter estimates or inhibit the ability to derive accurate plasma/tokamak system models. To address this issue, we have developed more formal power systems change control and power system/magnetic diagnostics calibration procedures. This paper discusses our approach to consolidating the tasks in these closely related areas. This includes, for example, defining criteria for when diagnostics should be re-calibrated along with required calibration tolerances, and implementing methods for tracking power systems hardware modifications and the resultant changes to control models

  1. TU-H-CAMPUS-JeP3-02: Automated Dose Accumulation and Dose Accuracy Assessment for Online Or Offline Adaptive Replanning

    International Nuclear Information System (INIS)

    Chen, G; Ahunbay, E; Li, X

    2016-01-01

    Purpose: With introduction of high-quality treatment imaging during radiation therapy (RT) delivery, e.g., MR-Linac, adaptive replanning of either online or offline becomes appealing. Dose accumulation of delivered fractions, a prerequisite for the adaptive replanning, can be cumbersome and inaccurate. The purpose of this work is to develop an automated process to accumulate daily doses and to assess the dose accumulation accuracy voxel-by-voxel for adaptive replanning. Methods: The process includes the following main steps: 1) reconstructing daily dose for each delivered fraction with a treatment planning system (Monaco, Elekta) based on the daily images using machine delivery log file and considering patient repositioning if applicable, 2) overlaying the daily dose to the planning image based on deformable image registering (DIR) (ADMIRE, Elekta), 3) assessing voxel dose deformation accuracy based on deformation field using predetermined criteria, and 4) outputting accumulated dose and dose-accuracy volume histograms and parameters. Daily CTs acquired using a CT-on-rails during routine CT-guided RT for sample patients with head and neck and prostate cancers were used to test the process. Results: Daily and accumulated doses (dose-volume histograms, etc) along with their accuracies (dose-accuracy volume histogram) can be robustly generated using the proposed process. The test data for a head and neck cancer case shows that the gross tumor volume decreased by 20% towards the end of treatment course, and the parotid gland mean dose increased by 10%. Such information would trigger adaptive replanning for the subsequent fractions. The voxel-based accuracy in the accumulated dose showed that errors in accumulated dose near rigid structures were small. Conclusion: A procedure as well as necessary tools to automatically accumulate daily dose and assess dose accumulation accuracy is developed and is useful for adaptive replanning. Partially supported by Elekta, Inc.

  2. Fuel safety criteria technical review - Results of OECD/CSNI/PWG2 Task Force on Fuel Safety Criteria

    International Nuclear Information System (INIS)

    Hollasky, N.; Valtonen, K.; Hache, G.; Gross, H.; Bakker, K.; Recio, M.; Bart, G.; Zimmermann, M.; Van Doesburg, W.; Killeen, J.; Meyer, R.O.; Speis, T.

    2000-01-01

    With the advent of advanced fuel and core designs, the adoption of more aggressive operational modes and the implementation of more accurate (best estimate or statistical) design and analysis methods, there is a concern if safety margins have remained adequate. Most - if not all - of the currently existing safety criteria were established during the 60's and early 70's, and verified against experiments with fuel that was available at that time, mostly with unirradiated specimens. Verification was of course performed as designs progressed in later years, however mostly with the aim to be able to prove that these designs adequately complied with existing criteria, and not to establish new limits. The OECD/CSNI/PWG2 Task Force on Fuel Safety Criteria (TFFSC) was therefore given the mandate to technically review the existing fuel safety criteria, focusing on the 'new design' elements (new fuel and core design, cladding materials, manufacturing processes, high burnup, MOX, etc.) introduced by the industry. It should also identify if additional efforts may be required (experimental, analytical) to ensure that the basis for fuel safety criteria is adequate to address the relevant safety issues. In this report, fuel-related criteria are discussed without attempting to categorize them according to event type or risk significance. For each of these 20 criteria, we present a brief description of the criterion as it is used in several applications along with the rationale for having such a criterion. New design elements, such as different cladding materials, higher burnup, and the use of MOX fuels, can affect fuel-related margins and, in some cases, the criteria themselves. Some of the more important effects are mentioned in order to indicate whether the criteria need to be re-evaluated. The discussion may not cover all possible effects, but should be sufficient to identify those criteria that need to be addressed. A summary of these discussions is given in Section 7. As part

  3. Relation between riding quality of MAGLEV vehicle and guideway construction accuracy. Chodendo jiki fujoshiki tetsudo guideway no seko seido to norigokochi level

    Energy Technology Data Exchange (ETDEWEB)

    Matsuura, A; Hashimoto, S; Furukawa, A [Railway Technology Research Institute, Tokyo (Japan)

    1994-01-15

    Good riding quality of MAGLEV vehicle requires construction of its guideway to a high level of accuracy. This paper discusses the relation of the power spectrum density (hereinafter the PSD) made up of guideway construction accuracy and its deviation with the level of riding comfort. The discussion uses the 'riding comfort affecting coefficient' consisting of the unit construction length, vehicle's travelling speed, and vibration characteristics. The PSD, which has been used to evaluate track deviation in the iron wheel/rail system railways, is derived from the number of limit exceeded point, the value 'P' as a track deviation coefficient, and the PSD. The relation between the standard deviation in construction errors and the PSD was derived based on track construction methods. This calculation method is characterized by a function with a step form. The relation between the deviation and the level was quantified using this PSD. Its practicability was verified by a simulated re-inspection of the guideway deviation. Correlation between the level and the construction accuracy was elucidated, and a method for determining the criteria for construction accuracy was established. A side wall beam installing vehicle has been fabricated on a trial basis for a side wall system for the guideway, and installation accuracy tests are being carried out. 14 refs., 12 figs., 3 tabs.

  4. Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy Diagnostic Task Force Criteria Impact of New Task Force Criteria

    NARCIS (Netherlands)

    Cox, Moniek G. P. J.; van der Smagt, Jasper J.; Noorman, Maartje; Wiesfeld, Ans C.; Volders, Paul G. A.; van Langen, Irene M.; Atsma, Douwe E.; Dooijes, Dennis; Houweling, Arjan C.; Loh, Peter; Jordaens, Luc; Arens, Yvonne; Cramer, Maarten J.; Doevendans, Pieter A.; van Tintelen, Peter; Wilde, Arthur A. M.; Hauer, Richard N. W.

    Background-Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy (ARVD/C) Diagnostic Task Force Criteria (TFC) proposed in 1994 are highly specific but lack sensitivity. A new international task force modified criteria to improve diagnostic yield. A comparison of diagnosis by 1994 TFC versus

  5. OSCILLATION CRITERIA FOR FORCED SUPERLINEAR DIFFERENCE EQUATIONS

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Using Riccati transformation techniques,some oscillation criteria for the forced second-order superlinear difference equations are established.These criteria are dis- crete analogues of the criteria for differential equations proposed by Yan.

  6. Test expectancy affects metacomprehension accuracy.

    Science.gov (United States)

    Thiede, Keith W; Wiley, Jennifer; Griffin, Thomas D

    2011-06-01

    Theory suggests that the accuracy of metacognitive monitoring is affected by the cues used to judge learning. Researchers have improved monitoring accuracy by directing attention to more appropriate cues; however, this is the first study to more directly point students to more appropriate cues using instructions regarding tests and practice tests. The purpose of the present study was to examine whether the accuracy metacognitive monitoring was affected by the nature of the test expected. Students (N= 59) were randomly assigned to one of two test expectancy groups (memory vs. inference). Then after reading texts, judging learning, completed both memory and inference tests. Test performance and monitoring accuracy were superior when students received the kind of test they had been led to expect rather than the unexpected test. Tests influence students' perceptions of what constitutes learning. Our findings suggest that this could affect how students prepare for tests and how they monitoring their own learning. ©2010 The British Psychological Society.

  7. Internet search term affects the quality and accuracy of online information about developmental hip dysplasia.

    Science.gov (United States)

    Fabricant, Peter D; Dy, Christopher J; Patel, Ronak M; Blanco, John S; Doyle, Shevaun M

    2013-06-01

    The recent emphasis on shared decision-making has increased the role of the Internet as a readily accessible medical reference source for patients and families. However, the lack of professional review creates concern over the quality, accuracy, and readability of medical information available to patients on the Internet. Three Internet search engines (Google, Yahoo, and Bing) were evaluated prospectively using 3 difference search terms of varying sophistication ("congenital hip dislocation," "developmental dysplasia of the hip," and "hip dysplasia in children"). Sixty-three unique Web sites were evaluated by each of 3 surgeons (2 fellowship-trained pediatric orthopaedic attendings and 1 orthopaedic chief resident) for quality and accuracy using a set of scoring criteria based on the AAOS/POSNA patient education Web site. The readability (literacy grade level) of each Web site was assessed using the Fleisch-Kincaid score. There were significant differences noted in quality, accuracy, and readability of information depending on the search term used. The search term "developmental dysplasia of the hip" provided higher quality and accuracy compared with the search term "congenital hip dislocation." Of the 63 total Web sites, 1 (1.6%) was below the sixth grade reading level recommended by the NIH for health education materials and 8 (12.7%) Web sites were below the average American reading level (eighth grade). The quality and accuracy of information available on the Internet regarding developmental hip dysplasia significantly varied with the search term used. Patients seeking information about DDH on the Internet may not understand the materials found because nearly all of the Web sites are written at a level above that recommended for publically distributed health information. Physicians should advise their patients to search for information using the term "developmental dysplasia of the hip" or, better yet, should refer patients to Web sites that they have

  8. Pedicle Screw Insertion Accuracy Using O-Arm, Robotic Guidance, or Freehand Technique: A Comparative Study.

    Science.gov (United States)

    Laudato, Pietro Aniello; Pierzchala, Katarzyna; Schizas, Constantin

    2018-03-15

    A retrospective radiological study. The aim of this study was to evaluate the accuracy of pedicle screw insertion using O-Arm navigation, robotic assistance, or a freehand fluoroscopic technique. Pedicle screw insertion using either "O-Arm" navigation or robotic devices is gaining popularity. Although several studies are available evaluating each of those techniques separately, no direct comparison has been attempted. Eighty-four patients undergoing implantation of 569 lumbar and thoracic screws were divided into three groups. Eleven patients (64 screws) had screws inserted using robotic assistance, 25 patients (191 screws) using the O-arm, while 48 patients (314 screws) had screws inserted using lateral fluoroscopy in a freehand technique. A single experienced spine surgeon assisted by a spinal fellow performed all procedures. Screw placement accuracy was assessed by two independent observers on postoperative computed tomography (CTs) according to the A to D Rampersaud criteria. No statistically significant difference was noted between the three groups. About 70.4% of screws in the freehand group, 69.6% in the O arm group, and 78.8% in the robotic group were placed completely within the pedicle margins (grade A) (P > 0.05). About 6.4% of screws were considered misplaced (grades C&D) in the freehand group, 4.2% in the O-arm group, and 4.7% in the robotic group (P > 0.05). The spinal fellow inserted screws with the same accuracy as the senior surgeon (P > 0.05). The advent of new technologies does not appear to alter accuracy of screw placement in our setting. Under supervision, spinal fellows might perform equally well to experienced surgeons using new tools. The lack of difference in accuracy does not imply that the above-mentioned techniques have no added advantages. Other issues, such as surgeon/patient radiation, fiddle factor, teaching suitability, etc., outside the scope of our present study, need further assessment. 3.

  9. Principles and Criteria for Design

    DEFF Research Database (Denmark)

    Beghin, D.; Cervetto, D.; Hansen, Peter Friis

    1997-01-01

    The mandate of ISSC Committee IV.1 on principles and Criteria for Design is to report on the following:The ongoing concern for quantification of general economic and safety criteria for marine structures and for the development of appropriate principles for rational life cycle design using...

  10. Diagnostic criteria for vascular dementia

    NARCIS (Netherlands)

    Scheltens, P.; Hijdra, A. H.

    1998-01-01

    The term vascular dementia implies the presence of a clinical syndrome (dementia) caused by, or at least assumed to be caused by, a specific disorder (cerebrovascular disease). In this review, the various sets of criteria used to define vascular dementia are outlined. The various sets of criteria

  11. Recommended criteria for the evaluation of on-site nuclear power plant emergency plans, volume II: criteria

    International Nuclear Information System (INIS)

    1997-01-01

    A critical review of existing Canadian and international nuclear power plant (NPP) emergency plans, evaluation criteria, and approaches has been conducted to provide AECB staff with information which can be used to assess the adequacy of NPP on-site emergency response plans. The results of this work are published in two volumes. Volume I, Basis Document, provides the reasons why certain requirements are in place. It also gives comprehensive references to various standards.Volume II, Criteria, contains the criteria which relate to on-site actions and their integration with control room activities and the roles of off-site responsible organizations. The recommended criteria provide information on what is required, and not on how to accomplish the requirements. The licensees are given the latitude to decide on the methods and processes needed to meet the requirements. The documents do not address NPP off-site plans and response capability, or the control room emergency operating procedures and response capability. This report contains only Volume II: Criteria. 55 refs., 2 tabs., 1 fig

  12. The accuracy and reproducibility of video assessment in the pitch-side management of concussion in elite rugby.

    Science.gov (United States)

    Fuller, G W; Kemp, S P T; Raftery, M

    2017-03-01

    To investigate the accuracy and reliability of side-line video review of head impact events to aid identification of concussion in elite sport. Diagnostic accuracy and inter-rater agreement study. Immediate care, match day and team doctors involved in the 2015 Rugby Union World Cup viewed 20 video clips showing broadcaster's footage of head impact events occurring during elite Rugby matches. Subjects subsequently recorded whether any criteria warranting permanent removal from play or medical room head injury assessment were present. The accuracy of these ratings were compared to consensus expert opinion by calculating mean sensitivity and specificity across raters. The reproducibility of doctor's decisions was additionally assessed using raw agreement and Gwets AC1 chance corrected agreement coefficient. Forty rugby medicine doctors were included in the study. Compared to the expert reference standard overall sensitivity and specificity of doctors decisions were 77.5% (95% CI 73.1-81.5%) and 53.3% (95% CI 48.2-58.2%) respectively. Overall there was raw agreement of 67.8% (95% CI 57.9-77.7%) between doctors across all video clips. Chance corrected Gwets AC1 agreement coefficient was 0.39 (95% CI 0.17-0.62), indicating fair agreement. Rugby World Cup doctors' demonstrated moderate accuracy and fair reproducibility in head injury event decision making when assessing video clips of head impact events. The use of real-time video may improve the identification, decision making and management of concussion in elite sports. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  13. Accuracy of diagnostic imaging modalities for peripheral post-traumatic osteomyelitis - a systematic review of the recent literature

    Energy Technology Data Exchange (ETDEWEB)

    Govaert, Geertje A. [University of Groningen, University Medical Center Groningen, Department of Surgery, Subdivision of Trauma Surgery, Groningen (Netherlands); University of Utrecht, University Medical Center Utrecht, Department of Trauma Surgery, Utrecht (Netherlands); IJpma, Frank F.; Reininga, Inge H. [University of Groningen, University Medical Center Groningen, Department of Surgery, Subdivision of Trauma Surgery, Groningen (Netherlands); McNally, Martin [Oxford University Hospitals NHS Foundation Trust, The Bone Infection Unit, Nuffield Orthopaedic Centre, Oxford (United Kingdom); McNally, Eugene [Oxford Musculoskeletal Radiology, Oxford (United Kingdom); Glaudemans, Andor W. [University of Groningen, University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands)

    2017-08-15

    Post-traumatic osteomyelitis (PTO) is difficult to diagnose and there is no consensus on the best imaging strategy. The aim of this study is to present a systematic review of the recent literature on diagnostic imaging of PTO. A literature search of the EMBASE and PubMed databases of the last 16 years (2000-2016) was performed. Studies that evaluated the accuracy of magnetic resonance imaging (MRI), three-phase bone scintigraphy (TPBS), white blood cell (WBC) or antigranulocyte antibody (AGA) scintigraphy, fluorodeoxyglucose positron emission tomography (FDG-PET) and plain computed tomography (CT) in diagnosing PTO were considered for inclusion. The review was conducted using the PRISMA statement and QUADAS-2 criteria. The literature search identified 3358 original records, of which 10 articles could be included in this review. Four of these studies had a comparative design which made it possible to report the results of, in total, 17 patient series. WBC (or AGA) scintigraphy and FDG-PET exhibit good accuracy for diagnosing PTO (sensitivity ranged from 50-100%, specificity ranged from 40-97% versus 83-100% and 51%-100%, respectively). The accuracy of both modalities improved when a hybrid imaging technique (SPECT/CT and FDG-PET/CT) was performed. For FDG-PET/CT, sensitivity ranged between 86 and 94% and specificity between 76 and 100%. For WBC scintigraphy + SPECT/CT, this is 100% and 89-97%, respectively. Based on the best available evidence of the last 16 years, both WBC (or AGA) scintigraphy combined with SPECT/CT or FDG-PET combined with CT have the best diagnostic accuracy for diagnosing peripheral PTO. (orig.)

  14. Social Advertising Quality: Assessment Criteria

    Directory of Open Access Journals (Sweden)

    S. B. Kalmykov

    2017-01-01

    Full Text Available Purpose: the The purpose of the publication is development of existing criterial assessment in social advertising sphere. The next objectives are provided for its achievement: to establish research methodology, to develop the author’s version of necessary notional apparatus and conceptual generalization, to determine the elements of social advertising quality, to establish the factors of its quality, to conduct the systematization of existing criteria and measuring instruments of quality assessment, to form new criteria of social advertising quality, to apply received results for development of criterial assessment to determine the further research perspectives. Methods: the methodology of research of management of social advertising interaction with target audience, which has dynamic procedural character with use of sociological knowledge multivariate paradigmatic status, has been proposed. Results: the primary received results: the multivariate paradigmatic research basis with use of works of famous domestic and foreign scientists in sociology, qualimetry and management spheres; the definitions of social advertising, its quality, sociological quality provision system, target audience behavior model during social advertising interaction are offered; the quality factors with three groups by level of effect on consumer are established; the systematization of existing quality and its measure instruments assessment criteria by detected social advertising quality elements are conducted; the two new criteria and its management quality assessment measuring instruments in social advertising sphere are developed; the one of the common groups of production quality criteria – adaptability with considering of new management quality criteria and conducted systematization of existing social advertising creative quality assessment criteria development; the perspective of further perfection of quality criterial assessment based on social advertising

  15. Computed tomography coronary angiography accuracy in women and men at low to intermediate risk of coronary artery disease

    International Nuclear Information System (INIS)

    Dharampal, Anoeshka S.; Papadopoulou, Stella L.; Rossi, Alexia; Weustink, Annick C.; Mollet, Nico R.A.; Meijboom, W. Bob; Neefjes, Lisan A.; Nieman, Koen; Feijter, Pim J. de; Boersma, Eric; Krestin, Gabriel P.

    2012-01-01

    To investigate the diagnostic accuracy of CT coronary angiography (CTCA) in women at low to intermediate pre-test probability of coronary artery disease (CAD) compared with men. In this retrospective study we included symptomatic patients with low to intermediate risk who underwent both invasive coronary angiography and CTCA. Exclusion criteria were previous revascularisation or myocardial infarction. The pre-test probability of CAD was estimated using the Duke risk score. Thresholds of less than 30 % and 30-90 % were used for determining low and intermediate risk, respectively. The diagnostic accuracy of CTCA in detecting obstructive CAD (≥50 % lumen diameter narrowing) was calculated on patient level. P < 0.05 was considered significant. A total of 570 patients (46 % women [262/570]) were included and stratified as low (women 73 % [80/109]) and intermediate risk (women 39 % [182/461]). Sensitivity, specificity, PPV and NPV were not significantly different in and between women and men at low and intermediate risk. For women vs. men at low risk they were 97 % vs. 100 %, 79 % vs. 90 %, 80 % vs. 80 % and 97 % vs. 100 %, respectively. For intermediate risk they were 99 % vs. 99 %, 72 % vs. 83 %, 88 % vs. 93 % and 98 % vs. 99 %, respectively. CTCA has similar diagnostic accuracy in women and men at low and intermediate risk. (orig.)

  16. Evolving fuzzy rules for relaxed-criteria negotiation.

    Science.gov (United States)

    Sim, Kwang Mong

    2008-12-01

    In the literature on automated negotiation, very few negotiation agents are designed with the flexibility to slightly relax their negotiation criteria to reach a consensus more rapidly and with more certainty. Furthermore, these relaxed-criteria negotiation agents were not equipped with the ability to enhance their performance by learning and evolving their relaxed-criteria negotiation rules. The impetus of this work is designing market-driven negotiation agents (MDAs) that not only have the flexibility of relaxing bargaining criteria using fuzzy rules, but can also evolve their structures by learning new relaxed-criteria fuzzy rules to improve their negotiation outcomes as they participate in negotiations in more e-markets. To this end, an evolutionary algorithm for adapting and evolving relaxed-criteria fuzzy rules was developed. Implementing the idea in a testbed, two kinds of experiments for evaluating and comparing EvEMDAs (MDAs with relaxed-criteria rules that are evolved using the evolutionary algorithm) and EMDAs (MDAs with relaxed-criteria rules that are manually constructed) were carried out through stochastic simulations. Empirical results show that: 1) EvEMDAs generally outperformed EMDAs in different types of e-markets and 2) the negotiation outcomes of EvEMDAs generally improved as they negotiated in more e-markets.

  17. Diagnostic accuracy of history, physical examination, and bedside ultrasound for diagnosis of extremity fractures in the emergency department: a systematic review.

    Science.gov (United States)

    Joshi, Nikita; Lira, Alena; Mehta, Ninfa; Paladino, Lorenzo; Sinert, Richard

    2013-01-01

    Understanding history, physical examination, and ultrasonography (US) to diagnose extremity fractures compared with radiography has potential benefits of decreasing radiation exposure, costs, and pain and improving emergency department (ED) resource management and triage time. The authors performed two electronic searches using PubMed and EMBASE databases for studies published between 1965 to 2012 using a strategy based on the inclusion of any patient presenting with extremity injuries suspicious for fracture who had history and physical examination and a separate search for US performed by an emergency physician (EP) with subsequent radiography. The primary outcome was operating characteristics of ED history, physical examination, and US in diagnosing radiologically proven extremity fractures. The methodologic quality of the studies was assessed using the quality assessment of studies of diagnostic accuracy tool (QUADAS-2). Nine studies met the inclusion criteria for history and physical examination, while eight studies met the inclusion criteria for US. There was significant heterogeneity in the studies that prevented data pooling. Data were organized into subgroups based on anatomic fracture locations, but heterogeneity within the subgroups also prevented data pooling. The prevalence of fracture varied among the studies from 22% to 70%. Upper extremity physical examination tests have positive likelihood ratios (LRs) ranging from 1.2 to infinity and negative LRs ranging from 0 to 0.8. US sensitivities varied between 85% and 100%, specificities varied between 73% and 100%, positive LRs varied between 3.2 and 56.1, and negative LRs varied between 0 and 0.2. Compared with radiography, EP US is an accurate diagnostic test to rule in or rule out extremity fractures. The diagnostic accuracy for history and physical examination are inconclusive. Future research is needed to understand the accuracy of ED US when combined with history and physical examination for upper

  18. Summarized water quality criteria

    International Nuclear Information System (INIS)

    Kempster, P.L.; Hattingh, W.H.J.; Van Vliet, H.R.

    1980-08-01

    The available world literature from 27 sources on existing water quality criteria are summarized for the 15 main uses of water. The minimum, median and maximum specified values for 96 different determinands are included. Under each water use the criteria are grouped according to the functional significance of the determinands e.g. aesthetic/physical effects, high toxic potential, low toxic potential etc. A synopsis is included summarizing salient facts for each determinand such as the conditions under which it is toxic and its relationship to other determinands. The significance of the criteria is briefly discussed and the importance of considering functional interactions between determinands emphasized in evaluating the potential for toxic or beneficial effects. From the source literature it appears that the toxic potential, in addition to being determined by concentration, is also affected by the origin of the substance concerned, i.e. whether from natural sources or from anthropogenic pollution

  19. Test Expectancy Affects Metacomprehension Accuracy

    Science.gov (United States)

    Thiede, Keith W.; Wiley, Jennifer; Griffin, Thomas D.

    2011-01-01

    Background: Theory suggests that the accuracy of metacognitive monitoring is affected by the cues used to judge learning. Researchers have improved monitoring accuracy by directing attention to more appropriate cues; however, this is the first study to more directly point students to more appropriate cues using instructions regarding tests and…

  20. Design of a six-component side-wall balance using optical fibre sensors

    CSIR Research Space (South Africa)

    Pieterse, FF

    2017-01-01

    Full Text Available The requirements that a wind tunnel balance need to satisfy have become increasingly stringent. These requirements, as set out by the wind tunnel testing community, include: improved static force accuracy and resolution, increased stiffness...

  1. NWTS program criteria for mined geologic disposal of nuclear waste: program objectives, functional requirements, and system performance criteria

    International Nuclear Information System (INIS)

    1982-03-01

    The NWTS-33 series, of which this document is a part, provides guidance for the National Waste Terminal Storage (NWTS) program in the development and implementation of licensed mined geologic disposal systems for solidified high-level and TRU wastes. Program objectives, functional requirements, and system performance criteria are found in this document. At the present time final criteria have not been issued by the Nuclear Regulatory Commission (NRC) and Environmental Protection Agency (EPA). The criteria in these documents have been developed on the basis of DOE's judgment of what is required to protect the health and safety of the public and the quality of the environment. It is expected that these criteria will be consistent with regulatory standards. The criteria will be re-evaluated on a periodic basis to ensure that they remain consistent with national waste management policy and regulatory requirements. A re-evaluation will be made when final criteria are promulgated by the NRC and EPA. A background section that briefly describes the mined geologic disposal system and explains the hierarchy and application of the NWTS criteria is included in Section 2.0. Secton 3.0 presents the program objectives, Section 4.0 functional requirements, Secton 5.0 the system performance criteria, and Section 6.0 quality assurance and standards. A draft of this document was issued for public comment in April 1981. Appendix A contains the DOE responses to the comments received. Appendix B is a glossary

  2. Updated clinical diagnostic criteria for sporadic Creutzfeldt-Jakob disease

    Science.gov (United States)

    Kallenberg, K.; Summers, D. M.; Romero, C.; Taratuto, A.; Heinemann, U.; Breithaupt, M.; Varges, D.; Meissner, B.; Ladogana, A.; Schuur, M.; Haik, S.; Collins, S. J.; Jansen, Gerard H.; Stokin, G. B.; Pimentel, J.; Hewer, E.; Collie, D.; Smith, P.; Roberts, H.; Brandel, J. P.; van Duijn, C.; Pocchiari, M.; Begue, C.; Cras, P.; Will, R. G.; Sanchez-Juan, P.

    2009-01-01

    Several molecular subtypes of sporadic Creutzfeldt–Jakob disease have been identified and electroencephalogram and cerebrospinal fluid biomarkers have been reported to support clinical diagnosis but with variable utility according to subtype. In recent years, a series of publications have demonstrated a potentially important role for magnetic resonance imaging in the pre-mortem diagnosis of sporadic Creutzfeldt–Jakob disease. Magnetic resonance imaging signal alterations correlate with distinct sporadic Creutzfeldt–Jakob disease molecular subtypes and thus might contribute to the earlier identification of the whole spectrum of sporadic Creutzfeldt–Jakob disease cases. This multi-centre international study aimed to provide a rationale for the amendment of the clinical diagnostic criteria for sporadic Creutzfeldt–Jakob disease. Patients with sporadic Creutzfeldt–Jakob disease and fluid attenuated inversion recovery or diffusion-weight imaging were recruited from 12 countries. Patients referred as ‘suspected sporadic Creutzfeldt–Jakob disease’ but with an alternative diagnosis after thorough follow up, were analysed as controls. All magnetic resonance imaging scans were assessed for signal changes according to a standard protocol encompassing seven cortical regions, basal ganglia, thalamus and cerebellum. Magnetic resonance imaging scans were evaluated in 436 sporadic Creutzfeldt–Jakob disease patients and 141 controls. The pattern of high signal intensity with the best sensitivity and specificity in the differential diagnosis of sporadic Creutzfeldt–Jakob disease was identified. The optimum diagnostic accuracy in the differential diagnosis of rapid progressive dementia was obtained when either at least two cortical regions (temporal, parietal or occipital) or both caudate nucleus and putamen displayed a high signal in fluid attenuated inversion recovery or diffusion-weight imaging magnetic resonance imaging. Based on our analyses, magnetic

  3. Nuclear controls are stringent

    International Nuclear Information System (INIS)

    Sonnekus, D.

    1983-01-01

    The peace-time application of nuclear power in South Africa, the organisations concerned and certain provisions laid down by the Act on Nuclear Energy, aimed at safeguarding the general public, are discussed

  4. Criteria for onsite transfers of radioactive material

    International Nuclear Information System (INIS)

    Opperman, E.K.; Jackson, E.J.; Eggers, A.G.

    1992-01-01

    A general description of the requirements for making onsite transfers of radioactive material is provided in Chapter 2, along with the required sequencey of activities. Various criteria for package use are identified in Chapters 3-13. These criteria provide protection against undue radiation exposure. Package shielding, containment, and surface contamination requirements are established. Criteria for providing criticality safety are enumerated in Chapter 6. Criteria for providing hazards information are established in Chapter 13. A glossary is provided

  5. 40 CFR 258.24 - Air criteria.

    Science.gov (United States)

    2010-07-01

    ... SOLID WASTE LANDFILLS Operating Criteria § 258.24 Air criteria. (a) Owners or operators of all MSWLFs... wastes, silvicultural wastes, landclearing debris, diseased trees, or debris from emergency cleanup...

  6. Criteria voor het beoordelen van tentamenuitwerkingen in het vak Programmeren [Assessment Criteria in Computer Programming Courses

    NARCIS (Netherlands)

    van den Berg, Klaas; van Diepen, N.M.; van Dijk, H.W.; Koppelman, Hermannus; Moerkerke, G.; Roossink, H.J.

    Bij het beoordelen is het belangrijk te weten welke criteria gehanteerd moeten worden. Met behulp van een vragenlijstonderzoek onder de docenten is een beperkt aantal criteria geselecteerd die gehanteerd moeten worden bij de cursus Inleiding in het Programmeren.

  7. Total pancreatectomy for recurrent acute and chronic pancreatitis: a critical review of patient selection criteria

    Science.gov (United States)

    Faghih, Mahya; Gonzalez, Francisco Garcia; Makary, Martin A.; Singh, Vikesh K.

    2018-01-01

    Purpose of review Critical review of the indications for total pancreatectomy and highlight limitations in current diagnostic criteria for chronic pancreatitis. Recent findings The diagnosis of noncalcific chronic pancreatitis remains controversial because of an overreliance on nonspecific imaging and laboratories findings. Endoscopic ultrasound, s-magnetic resonance cholangiopancreatography, and/or endoscopic pancreatic function testing are often used to diagnose noncalcific chronic pancreatitis despite the fact that there is no gold standard for this condition. Abdominal pain is not specific for chronic pancreatitis and is more likely to be encountered in patients with functional gastrointestinal disorders based on the high incidence of these conditions. The duration of pain and opioid analgesic use results in central sensitization that adversely affects pain outcomes after total pancreatectomy. An alcoholic cause is associated with poorer pain outcomes after total pancreatectomy. Summary The lack of a gold standard for noncalcific chronic pancreatitis limits the diagnostic accuracy of imaging and laboratory tests. The pain of chronic pancreatitis is nonspecific and is affected by duration, preoperative opioid use, and cause. These factors will need to be considered in the development of future selection criteria for this morbid surgery. PMID:28700371

  8. Chondromalacia patellae: an in vitro study. Comparison of MR criteria with histologic and macroscopic findings.

    Science.gov (United States)

    van Leersum, M; Schweitzer, M E; Gannon, F; Finkel, G; Vinitski, S; Mitchell, D G

    1996-11-01

    To develop MR criteria for grades of chondromalacia patellae and to assess the accuracy of these grades. Fat-suppressed T2-weighted double-echo, fat-suppressed T2-weighted fast spin echo, fat-suppressed T1-weighted, and gradient echo sequences were performed at 1.5 T for the evaluation of chondromalacia. A total of 1000 MR, 200 histologic, and 200 surface locations were graded for chondromalacia and statistically compared. Compared with gross inspection as well as with histology the most accurate sequences were fat-suppressed T2-weighted conventional spin echo and fat suppressed T2-weighted fast spin echo, although the T1-weighted and proton density images also correlated well. The most accurate MR criteria applied to the severe grades of chondromalacia, with less accurate results for lesser grades. This study demonstrates that fat-suppressed routine T2-weighted and fast spin echo T2-weighted sequences seem to be more accurate than proton density, T1-weighted, and gradient echo sequences in grading chondromalacia. Good histologic and macroscopic correlation was seen in more severe grades of chondromalacia, but problems remain for the early grades in all sequences studied.

  9. State-wide performance criteria for international safeguards

    International Nuclear Information System (INIS)

    Budlong-Sylvester, K.W.; Pilat, Joseph F.; Stanbro, W.D.

    2001-01-01

    Traditionally, the International Atomic Energy Agency (IAEA) has relied upon prescriptive criteria to guide safeguards implementation. The prospect of replacing prescriptive safeguards criteria with more flexible performance criteria would constitute a structural change in safeguards and raises several important questions. Performance criteria imply that while safeguards goals will be fixed, the means of attaining those goals will not be explicitly prescribed. What would the performance objectives be under such a system? How would they be formulated? How would performance be linked to higher level safeguards objectives? How would safeguards performance be measured State-wide? The implementation of safeguards under performance criteria would also signal a dramatic change in the manner the Agency does business. A higher degree of flexibility could, in principle, produce greater effectiveness and efficiency, but would come with a need for increased Agency responsibility in practice. To the extent that reliance on prescriptive criteria decreases, the burden of justifying actions and ensuring their transparency will rise. Would there need to be limits to safeguards implementation? What would be the basis for setting such limits? This paper addresses these and other issues and questions relating to both the formulation and the implementation of performance-based criteria.

  10. Direct-to-physician and direct-to-consumer advertising: Time to have stringent regulations.

    Science.gov (United States)

    Kannan, S; Gowri, S; Tyagi, V; Kohli, S; Jain, R; Kapil, P; Bhardwaj, A

    2015-01-01

    the opinion regarding DTCA, 69.9% physicians had a patient discussing DTCA that was clinically inappropriate. One hundred (64.5%) out of 155 physicians opined that DTCA encourage patients to attend physicians regarding preventive healthcare. On the contrary, 82/155 (52.9%) physicians felt that DTCA would damage the same. Similarly, 69 out of the total 100 patients felt that drug advertisements aid them to have better discussions with their treating physicians. Surprisingly, a large majority (91/100) were of the opinion that only safe drugs are allowed to be advertised. To conclude, from the findings of this study both the physicians and patients should be cautious and not overzealous while dealing with drug advertisements or promotional literature. More stringent scrutiny and issue of WLs or blacklisting of indulging pharmaceutical companies are mandatory by the regulatory agency to contain the same.

  11. Diagnostic accuracy in virtual dermatopathology

    DEFF Research Database (Denmark)

    Mooney, E.; Kempf, W.; Jemec, G.B.E.

    2012-01-01

    Background Virtual microscopy is used for teaching medical students and residents and for in-training and certification examinations in the United States. However, no existing studies compare diagnostic accuracy using virtual slides and photomicrographs. The objective of this study was to compare...... diagnostic accuracy of dermatopathologists and pathologists using photomicrographs vs. digitized images, through a self-assessment examination, and to elucidate assessment of virtual dermatopathology. Methods Forty-five dermatopathologists and pathologists received a randomized combination of 15 virtual...... slides and photomicrographs with corresponding clinical photographs and information in a self-assessment examination format. Descriptive data analysis and comparison of groups were performed using a chi-square test. Results Diagnostic accuracy in dermatopathology using virtual dermatopathology...

  12. Accident analysis and DOE criteria

    International Nuclear Information System (INIS)

    Graf, J.M.; Elder, J.C.

    1982-01-01

    In analyzing the radiological consequences of major accidents at DOE facilities one finds that many facilities fall so far below the limits of DOE Order 6430 that compliance is easily demonstrated by simple analysis. For those cases where the amount of radioactive material and the dispersive energy available are enough for accident consequences to approach the limits, the models and assumptions used become critical. In some cases the models themselves are the difference between meeting the criteria or not meeting them. Further, in one case, we found that not only did the selection of models determine compliance but the selection of applicable criteria from different chapters of Order 6430 also made the difference. DOE has recognized the problem of different criteria in different chapters applying to one facility, and has proceeded to make changes for the sake of consistency. We have proposed to outline the specific steps needed in an accident analysis and suggest appropriate models, parameters, and assumptions. As a result we feed DOE siting and design criteria will be more fairly and consistently applied

  13. Radiological protection criteria for waste management

    International Nuclear Information System (INIS)

    Hill, M.D.; Webb, G.A.M.

    1985-01-01

    In this paper the progress being made by international organisations towards the development of a consensus on the radiological protection criteria to be applied to waste management, and in particular waste disposal, is reviewed. Against this background, work on the development of criteria for use in the UK is described. It is concluded that an international consensus is emerging and that the criteria being recommended for use in the UK are consistent with current international views. (author)

  14. Radiological protection criteria for waste management

    International Nuclear Information System (INIS)

    Hill, M.D.; Webb, G.A.M.

    1985-01-01

    In this Paper the progress being made by international organizations towards the development of a consensus on the radiological protection criteria to be applied to waste management, and in particular waste disposal, is reviewed. Against this background, work on the development of criteria for use in the UK is described. It is concluded that an international consensus is emerging and that the criteria being recommended for use in the UK are consistent with current international views. (author)

  15. Terahertz radiation source using a high-power industrial electron ...

    Indian Academy of Sciences (India)

    2017-03-27

    Mar 27, 2017 ... for pasteurization of food products, disinfection of medical waste, etc. We propose that ..... The selection of a narrow spec- trum around the central ..... not satisfy the stringent criteria on beam quality, can be used for the ...

  16. Predictive accuracy of changes in transvaginal sonographic cervical length over time for preterm birth: a systematic review and metaanalysis.

    Science.gov (United States)

    Conde-Agudelo, Agustin; Romero, Roberto

    2015-12-01

    To determine the accuracy of changes in transvaginal sonographic cervical length over time in predicting preterm birth in women with singleton and twin gestations. PubMed, Embase, Cinahl, Lilacs, and Medion (all from inception to June 30, 2015), bibliographies, Google scholar, and conference proceedings. Cohort or cross-sectional studies reporting on the predictive accuracy for preterm birth of changes in cervical length over time. Two reviewers independently selected studies, assessed the risk of bias, and extracted the data. Summary receiver-operating characteristic curves, pooled sensitivities and specificities, and summary likelihood ratios were generated. Fourteen studies met the inclusion criteria, of which 7 provided data on singleton gestations (3374 women) and 8 on twin gestations (1024 women). Among women with singleton gestations, the shortening of cervical length over time had a low predictive accuracy for preterm birth at predictive accuracy for preterm birth at predictive accuracies for preterm birth of cervical length shortening over time and the single initial and/or final cervical length measurement in 8 of 11 studies that provided data for making these comparisons. In the largest and highest-quality study, a single measurement of cervical length obtained at 24 or 28 weeks of gestation was significantly more predictive of preterm birth than any decrease in cervical length between these gestational ages. Change in transvaginal sonographic cervical length over time is not a clinically useful test to predict preterm birth in women with singleton or twin gestations. A single cervical length measurement obtained between 18 and 24 weeks of gestation appears to be a better test to predict preterm birth than changes in cervical length over time. Published by Elsevier Inc.

  17. Development of small reactor safety criteria in Canada

    International Nuclear Information System (INIS)

    Ernst, P.C.; French, P.M.; Axford, D.J.; Snell, V.G.

    1990-01-01

    A number of new small reactor designs have been proposed in Canada over the last several years and some have reached the stage where licensing discussions have been initiated with the Atomic Energy Control Board (AECB). An inter-organizational Small Reactor Criteria (SRC) working group was formed in 1988 to propose safety and licensing criteria for these small reactors. Two levels of criteria are proposed. The first level forms a safety philosophy and the second is a set of criteria for specific reactor applications. The safety philosophy consists of three basic safety objectives together with evaluation criteria, and fourteen fundamental principles measured by specific criteria, which must be implemented to meet the safety objectives. Two of the fourteen principles are prime: defence in depth, and safety culture; the other twelve principles can be seen as deriving from them. A benefit of this approach is that the concepts of defence in depth and safety culture become well-defined. The objectives and principles are presented in the paper and their criteria are summarized. The second level of criteria, under development, will form a safety application set and will provide small reactor criteria in a number of general areas, such as regulatory process and safety assessment, as well as for specific reactor life-cycle activities, from siting through to decommissioning. The criteria are largely deterministic. However, the frequencies and consequences of postulated accidents are assessed against numerical criteria to assist in judging the acceptability of plant design, operation, and proposed siting. All criteria proposed are designed to be testable in some evidentiary fashion, readily enabling an assessment of compliance for a given proposal

  18. MDS clinical diagnostic criteria for Parkinson's disease in China.

    Science.gov (United States)

    Li, Jun; Jin, Miao; Wang, Li; Qin, Bin; Wang, Kang

    2017-03-01

    The Movement Disorder Society Clinical Diagnostic Criteria for Parkinson's disease (MDS-PD Criteria) was introduced by the Movement Disorder Society in 2015 for research purposes. However, its use for clinical diagnosis of Parkinson disease still needs further revision. This study compares the UK-Criteria versus MDS-PD Criteria in the clinical diagnosis of Parkinson disease referred to the China-Japan Friendship Hospital of Beijing, China. To compare the MDS-PD Criteria with the UK-Criteria and discuss the feasibility of the clinical application of MDS-PD Criteria as a general guide to clinical diagnosis of PD in Chinese PD patients. 150 patients of neurology clinic of China-Japan Friendship Hospital of Beijing were recruited in our research. They were divided into three groups: UK-Criteria group, MDS-PD Criteria group and a combined group of UK and MDS-PD Criteria. Clinical history was collected while physical and auxiliary examinations were done by a trained neurologist according to the corresponding criteria. An interrater reliability analysis using the Kappa statistic claimed substantial agreement (κ = 0.626) between the MDS-PD Criteria and the UK-Criteria. The differences between the diagnostic results of these two criteria were statistically significant by paired Chi-square test (p = 0.000). It was found that levodopa-induced dyskinesia had a good positive predictive value, while early bulbar impairment and inspiratory dysfunction presented a negative predictive value. The MDS-PD Criteria emphasize the importance of non-motor symptoms, keeping the motor symptoms as the core for the clinical diagnosis of PD, and establish categories of diagnosis features and levels of certainty which are more complete and organized to be used and replicated by non specialized physicians to evaluated patients with Parkinsonism. The higher sensitivity of MDS-PD Criteria compared with UK-Criteria is worth being widely used in clinical work.

  19. 24 CFR 1003.400 - Criteria for funding.

    Science.gov (United States)

    2010-04-01

    ... tribal or Federal funding sources cannot be made available to alleviate the threat. (c) HUD will... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Criteria for funding. 1003.400... Grants § 1003.400 Criteria for funding. The following criteria apply to requests for assistance under...

  20. Improving Accuracy of Processing Through Active Control

    Directory of Open Access Journals (Sweden)

    N. N. Barbashov

    2016-01-01

    Full Text Available An important task of modern mathematical statistics with its methods based on the theory of probability is a scientific estimate of measurement results. There are certain costs under control, and under ineffective control when a customer has got defective products these costs are significantly higher because of parts recall.When machining the parts, under the influence of errors a range scatter of part dimensions is offset towards the tolerance limit. To improve a processing accuracy and avoid defective products involves reducing components of error in machining, i.e. to improve the accuracy of machine and tool, tool life, rigidity of the system, accuracy of the adjustment. In a given time it is also necessary to adapt machine.To improve an accuracy and a machining rate there, currently  become extensively popular various the in-process gaging devices and controlled machining that uses adaptive control systems for the process monitoring. Improving the accuracy in this case is compensation of a majority of technological errors. The in-cycle measuring sensors (sensors of active control allow processing accuracy improvement by one or two quality and provide a capability for simultaneous operation of several machines.Efficient use of in-cycle measuring sensors requires development of methods to control the accuracy through providing the appropriate adjustments. Methods based on the moving average, appear to be the most promising for accuracy control since they include data on the change in some last measured values of the parameter under control.

  1. Dose Calculation Accuracy of the Monte Carlo Algorithm for CyberKnife Compared with Other Commercially Available Dose Calculation Algorithms

    International Nuclear Information System (INIS)

    Sharma, Subhash; Ott, Joseph; Williams, Jamone; Dickow, Danny

    2011-01-01

    Monte Carlo dose calculation algorithms have the potential for greater accuracy than traditional model-based algorithms. This enhanced accuracy is particularly evident in regions of lateral scatter disequilibrium, which can develop during treatments incorporating small field sizes and low-density tissue. A heterogeneous slab phantom was used to evaluate the accuracy of several commercially available dose calculation algorithms, including Monte Carlo dose calculation for CyberKnife, Analytical Anisotropic Algorithm and Pencil Beam convolution for the Eclipse planning system, and convolution-superposition for the Xio planning system. The phantom accommodated slabs of varying density; comparisons between planned and measured dose distributions were accomplished with radiochromic film. The Monte Carlo algorithm provided the most accurate comparison between planned and measured dose distributions. In each phantom irradiation, the Monte Carlo predictions resulted in gamma analysis comparisons >97%, using acceptance criteria of 3% dose and 3-mm distance to agreement. In general, the gamma analysis comparisons for the other algorithms were <95%. The Monte Carlo dose calculation algorithm for CyberKnife provides more accurate dose distribution calculations in regions of lateral electron disequilibrium than commercially available model-based algorithms. This is primarily because of the ability of Monte Carlo algorithms to implicitly account for tissue heterogeneities, density scaling functions; and/or effective depth correction factors are not required.

  2. Design Criteria for Achieving Acceptable Indoor Radon Concentration

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2016-01-01

    Design criteria for achieving an acceptable indoor radon concentration are presented in this paper. The paper suggests three design criteria. These criteria have to be considered at the early stage of the building design phase to meet the latest recommendations from the World Health Organization...... in most countries. The three design criteria are; first, establishing a radon barrier facing the ground; second, lowering the air pressure in the lower zone of the slab on ground facing downwards; third, diluting the indoor air with outdoor air. The first two criteria can prevent radon from infiltrating...... from the ground, and the third criteria can dilute the indoor air. By combining these three criteria, the indoor radon concentration can be lowered achieving an acceptable level. In addition, a cheap and reliable method for measuring the radon concentration in the indoor air is described. The provision...

  3. Ebook Evaluation Criteria: A Proposed Checklist

    Directory of Open Access Journals (Sweden)

    Amir Ghaebi

    2010-09-01

    Full Text Available E-books embody diverse features, each of which could contribute towards increasing their user-agreeability and attracting more users. In order to select an Ebook best suited to their needs, both users and librarians consider a set of criteria. The present study aims at providing the evaluation criteria from the standpoint of both the users and librarys by employing two approaches, i.e. through considering the characteristics of the electronic environment, and also maintaining the desired features of the printed media in E-books. By reviewing the resources published in the field of E-books, 15 criteria along with 101 components have been collectively discussed for evaluation of the suitable E-book for users and libraries. Four criteria with 24 components have been solely devised for libraries and librarians.

  4. Water Quality Criteria

    Science.gov (United States)

    EPA develops water quality criteria based on the latest scientific knowledge to protect human health and aquatic life. This information serves as guidance to states and tribes in adopting water quality standards.

  5. Accuracy of Three-Dimensional Planning in Surgery-First Orthognathic Surgery: Planning Versus Outcome

    Science.gov (United States)

    Tran, Ngoc Hieu; Tantidhnazet, Syrina; Raocharernporn, Somchart; Kiattavornchareon, Sirichai; Pairuchvej, Verasak; Wongsirichat, Natthamet

    2018-01-01

    Background The benefit of computer-assisted planning in orthognathic surgery (OGS) has been extensively documented over the last decade. This study aimed to evaluate the accuracy of three-dimensional (3D) virtual planning in surgery-first OGS. Methods Fifteen patients with skeletal class III malocclusion who underwent bimaxillary OGS with surgery-first approach were included. A composite skull model was reconstructed using data from cone-beam computed tomography and stereolithography from a scanned dental cast. Surgical procedures were simulated using Simplant O&O software, and the virtual plan was transferred to the operation room using 3D-printed splints. Differences of the 3D measurements between the virtual plan and postoperative results were evaluated, and the accuracy was reported using root mean square deviation (RMSD) and the Bland-Altman method. Results The virtual planning was successfully transferred to surgery. The overall mean linear difference was 0.88 mm (0.79 mm for the maxilla and 1 mm for the mandible), and the overall mean angular difference was 1.16°. The RMSD ranged from 0.86 to 1.46 mm and 1.27° to 1.45°, within the acceptable clinical criteria. Conclusion In this study, virtual surgical planning and 3D-printed surgical splints facilitated the diagnosis and treatment planning, and offered an accurate outcome in surgery-first OGS. PMID:29581806

  6. Accuracy of Three-Dimensional Planning in Surgery-First Orthognathic Surgery: Planning Versus Outcome.

    Science.gov (United States)

    Tran, Ngoc Hieu; Tantidhnazet, Syrina; Raocharernporn, Somchart; Kiattavornchareon, Sirichai; Pairuchvej, Verasak; Wongsirichat, Natthamet

    2018-05-01

    The benefit of computer-assisted planning in orthognathic surgery (OGS) has been extensively documented over the last decade. This study aimed to evaluate the accuracy of three-dimensional (3D) virtual planning in surgery-first OGS. Fifteen patients with skeletal class III malocclusion who underwent bimaxillary OGS with surgery-first approach were included. A composite skull model was reconstructed using data from cone-beam computed tomography and stereolithography from a scanned dental cast. Surgical procedures were simulated using Simplant O&O software, and the virtual plan was transferred to the operation room using 3D-printed splints. Differences of the 3D measurements between the virtual plan and postoperative results were evaluated, and the accuracy was reported using root mean square deviation (RMSD) and the Bland-Altman method. The virtual planning was successfully transferred to surgery. The overall mean linear difference was 0.88 mm (0.79 mm for the maxilla and 1 mm for the mandible), and the overall mean angular difference was 1.16°. The RMSD ranged from 0.86 to 1.46 mm and 1.27° to 1.45°, within the acceptable clinical criteria. In this study, virtual surgical planning and 3D-printed surgical splints facilitated the diagnosis and treatment planning, and offered an accurate outcome in surgery-first OGS.

  7. Accuracy and precision in thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    Marshall, T.O.

    1984-01-01

    The question of accuracy and precision in thermoluminescent dosimetry, particularly in relation to lithium fluoride phosphor, is discussed. The more important sources of error, including those due to the detectors, the reader, annealing and dosemeter design, are identified and methods of reducing their effects on accuracy and precision to a minimum are given. Finally, the accuracy and precision achievable for three quite different applications are discussed, namely, for personal dosimetry, environmental monitoring and for the measurement of photon dose distributions in phantoms. (U.K.)

  8. Criteria for controlled atmosphere chambers

    International Nuclear Information System (INIS)

    Robinson, J.N.

    1980-03-01

    The criteria for design, construction, and operation of controlled atmosphere chambers intended for service at ORNL are presented. Classification of chambers, materials for construction, design criteria, design, controlled atmosphere chamber systems, and operating procedures are presented. ORNL Safety Manual Procedure 2.1; ORNL Health Physics Procedure Manual Appendix A-7; and Design of Viewing Windows are included in 3 appendices

  9. Quality criteria for cardiac images: An update

    International Nuclear Information System (INIS)

    Bernardi, G.; Bar, O.; Jezewski, T.; Vano, E.; Maccia, C.; Trianni, A.; Padovani, R.

    2008-01-01

    The DIMOND II and III Cardiology Groups have agreed on quality criteria for cardiac images and developed a scoring system, to provide a tool to test quality of coronary angiograms, which was demonstrated to be of value in clinical practice. In the last years, digital flat panel technology has been introduced in cardiac angiographic systems and the radiological technique may have been influenced by the better performance of these new detectors. This advance in digital imaging, together with the lesson learned from previous studies, warranted the revision of the quality criteria for cardiac angiographic images as formerly defined. DIMOND criteria were reassessed to allow a simpler evaluation of angiograms. Clinical criteria were simplified and separated from technical criteria. Furthermore, the characteristics of an optimised angiographic technique have been outlined. (authors)

  10. User perspectives on relevance criteria

    DEFF Research Database (Denmark)

    Maglaughlin, Kelly L.; Sonnenwald, Diane H.

    2002-01-01

    , partially relevant, or not relevant to their information need; and explained their decisions in an interview. Analysis revealed 29 criteria, discussed positively and negatively, that were used by the participants when selecting passages that contributed or detracted from a document's relevance......This study investigates the use of criteria to assess relevant, partially relevant, and not-relevant documents. Study participants identified passages within 20 document representations that they used to make relevance judgments; judged each document representation as a whole to be relevant...... matter, thought catalyst), full text (e.g., audience, novelty, type, possible content, utility), journal/publisher (e.g., novelty, main focus, perceived quality), and personal (e.g., competition, time requirements). Results further indicate that multiple criteria are used when making relevant, partially...

  11. A NSSS supplier's response to differing safety criteria

    International Nuclear Information System (INIS)

    Cremades, J.; Filkin, R.; Franke, Th.

    1980-01-01

    The limited progress achieved to date in harmonizing national criteria has led to the development of designs which include the most common national requirements. Progress towards harmonization of safety criteria can be accelerated by expanding the IAEA leadership and co-ordination activities, and implementing an integrated approach to criteria development. National and International safety criteria are examined. (author)

  12. Diagnosis of hearing loss using automated audiometry in an asynchronous telehealth model: A pilot accuracy study.

    Science.gov (United States)

    Brennan-Jones, Christopher G; Eikelboom, Robert H; Swanepoel, De Wet

    2017-02-01

    Introduction Standard criteria exist for diagnosing different types of hearing loss, yet audiologists interpret audiograms manually. This pilot study examined the feasibility of standardised interpretations of audiometry in a telehealth model of care. The aim of this study was to examine diagnostic accuracy of automated audiometry in adults with hearing loss in an asynchronous telehealth model using pre-defined diagnostic protocols. Materials and methods We recruited 42 study participants from a public audiology and otolaryngology clinic in Perth, Western Australia. Manual audiometry was performed by an audiologist either before or after automated audiometry. Diagnostic protocols were applied asynchronously for normal hearing, disabling hearing loss, conductive hearing loss and unilateral hearing loss. Sensitivity and specificity analyses were conducted using a two-by-two matrix and Cohen's kappa was used to measure agreement. Results The overall sensitivity for the diagnostic criteria was 0.88 (range: 0.86-1) and overall specificity was 0.93 (range: 0.86-0.97). Overall kappa ( k) agreement was 'substantial' k = 0.80 (95% confidence interval (CI) 0.70-0.89) and significant at p loss. This method has the potential to improve synchronous and asynchronous tele-audiology service delivery.

  13. Clinical relevance of studies on the accuracy of visual inspection for detecting caries lesions

    DEFF Research Database (Denmark)

    Gimenez, Thais; Piovesan, Chaiana; Braga, Mariana M

    2015-01-01

    Although visual inspection is the most commonly used method for caries detection, and consequently the most investigated, studies have not been concerned about the clinical relevance of this procedure. Therefore, we conducted a systematic review in order to perform a critical evaluation considering...... the clinical relevance and methodological quality of studies on the accuracy of visual inspection for assessing caries lesions. Two independent reviewers searched several databases through July 2013 to identify papers/articles published in English. Other sources were checked to identify unpublished literature...... to clinical relevance and the methodological quality of the studies were evaluated. 96 of the 5,578 articles initially identified met the inclusion criteria. In general, most studies failed in considering some clinically relevant aspects: only 1 included study validated activity status of lesions, no study...

  14. Cadastral Database Positional Accuracy Improvement

    Science.gov (United States)

    Hashim, N. M.; Omar, A. H.; Ramli, S. N. M.; Omar, K. M.; Din, N.

    2017-10-01

    Positional Accuracy Improvement (PAI) is the refining process of the geometry feature in a geospatial dataset to improve its actual position. This actual position relates to the absolute position in specific coordinate system and the relation to the neighborhood features. With the growth of spatial based technology especially Geographical Information System (GIS) and Global Navigation Satellite System (GNSS), the PAI campaign is inevitable especially to the legacy cadastral database. Integration of legacy dataset and higher accuracy dataset like GNSS observation is a potential solution for improving the legacy dataset. However, by merely integrating both datasets will lead to a distortion of the relative geometry. The improved dataset should be further treated to minimize inherent errors and fitting to the new accurate dataset. The main focus of this study is to describe a method of angular based Least Square Adjustment (LSA) for PAI process of legacy dataset. The existing high accuracy dataset known as National Digital Cadastral Database (NDCDB) is then used as bench mark to validate the results. It was found that the propose technique is highly possible for positional accuracy improvement of legacy spatial datasets.

  15. Diagnostic accuracy of the Eurotest for dementia: a naturalistic, multicenter phase II study

    Directory of Open Access Journals (Sweden)

    Frank Ana

    2006-04-01

    Full Text Available Abstract Background Available screening tests for dementia are of limited usefulness because they are influenced by the patient's culture and educational level. The Eurotest, an instrument based on the knowledge and handling of money, was designed to overcome these limitations. The objective of this study was to evaluate the diagnostic accuracy of the Eurotest in identifying dementia in customary clinical practice. Methods A cross-sectional, multi-center, naturalistic phase II study was conducted. The Eurotest was administered to consecutive patients, older than 60 years, in general neurology clinics. The patients' condition was classified as dementia or no dementia according to DSM-IV diagnostic criteria. We calculated sensitivity (Sn, specificity (Sp and area under the ROC curves (aROC with 95% confidence intervals. The influence of social and educational factors on scores was evaluated with multiple linear regression analysis, and the influence of these factors on diagnostic accuracy was evaluated with logistic regression. Results Sixteen neurologists recruited a total of 516 participants: 101 with dementia, 380 without dementia, and 35 who were excluded. Of the 481 participants who took the Eurotest, 38.7% were totally or functionally illiterate and 45.5% had received no formal education. Mean time needed to administer the test was 8.2+/-2.0 minutes. The best cut-off point was 20/21, with Sn = 0.91 (0.84–0.96, Sp = 0.82 (0.77–0.85, and aROC = 0.93 (0.91–0.95. Neither the scores on the Eurotest nor its diagnostic accuracy were influenced by social or educational factors. Conclusion This naturalistic and pragmatic study shows that the Eurotest is a rapid, simple and useful screening instrument, which is free from educational influences, and has appropriate internal and external validity.

  16. Diagnostic accuracy of post-mortem magnetic resonance imaging in fetuses, children and adults: A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Thayyil, Sudhin, E-mail: s.thayyil@ucl.ac.u [Centre for Cardiovascular Imaging, UCL Institute of Child Health, London (United Kingdom); UCL Institute for Women' s Health, London (United Kingdom); Chandrasekaran, Manigandan [UCL Institute for Women' s Health, London (United Kingdom); Chitty, Lyn S. [UCL Institute for Women' s Health, London (United Kingdom); Clinical Molecular Genetics Unit, UCL Institute of Child Health, London (United Kingdom); Wade, Angie [Medical Statistics, UCL Institute of Child Health (United Kingdom); Skordis-Worrall, Jolene [Centre for International Health and Development, UCL Institute of Child Health (United Kingdom); Bennett-Britton, Ian [Centre for International Health and Development, UCL Institute of Child Health (United Kingdom); Health Economics and Financing Program, London School of Hygiene and Tropical Medicine, London (United Kingdom); Cohen, Marta [Department of Histopathology, Sheffield Children' s Hospital, Sheffield (United Kingdom); Withby, Elspeth [Department of Academic Radiology, Sheffield Children' s Hospital, Sheffield (United Kingdom); Sebire, Neil J. [Department of Histopathology, UCL Institute of Child Health and Great Ormond Street Hospital for Children, London (United Kingdom); Robertson, Nicola J. [UCL Institute for Women' s Health, London (United Kingdom); Taylor, Andrew M. [Centre for Cardiovascular Imaging, UCL Institute of Child Health, London (United Kingdom)

    2010-07-15

    To determine, in a systematic review, the diagnostic accuracy, acceptability and cost-effectiveness of less invasive autopsy by post-mortem MR imaging, in fetuses, children and adults. We searched Medline, Embase, the Cochrane library and reference lists to identify all studies comparing post-mortem MR imaging with conventional autopsy, published between January 1990 and March 2009. 539 abstracts were identified; 15 papers met the inclusion criteria; data from 9 studies were extracted (total: 146 fetuses, 11 children and 24 adults). In accurately identifying the final cause of death or most clinically significant abnormality, post-mortem MR imaging had a sensitivity and specificity of 69% (95% CI-56%, 80%) and 95% (95% CI-88%, 98%) in fetuses, and 28% (95% CI-13%, 47%) and 64% (95% CI-23%, 94%) in children and adults, respectively; however the published data is limited to small, heterogenous and poorly designed studies. Insufficient data is available on acceptability and economic evaluation of post-mortem MR imaging. Well designed, large, prospective studies are required to evaluate the accuracy of post-mortem MR imaging, before it can be offered as a clinical tool.

  17. Diagnostic accuracy of post-mortem magnetic resonance imaging in fetuses, children and adults: A systematic review

    International Nuclear Information System (INIS)

    Thayyil, Sudhin; Chandrasekaran, Manigandan; Chitty, Lyn S.; Wade, Angie; Skordis-Worrall, Jolene; Bennett-Britton, Ian; Cohen, Marta; Withby, Elspeth; Sebire, Neil J.; Robertson, Nicola J.; Taylor, Andrew M.

    2010-01-01

    To determine, in a systematic review, the diagnostic accuracy, acceptability and cost-effectiveness of less invasive autopsy by post-mortem MR imaging, in fetuses, children and adults. We searched Medline, Embase, the Cochrane library and reference lists to identify all studies comparing post-mortem MR imaging with conventional autopsy, published between January 1990 and March 2009. 539 abstracts were identified; 15 papers met the inclusion criteria; data from 9 studies were extracted (total: 146 fetuses, 11 children and 24 adults). In accurately identifying the final cause of death or most clinically significant abnormality, post-mortem MR imaging had a sensitivity and specificity of 69% (95% CI-56%, 80%) and 95% (95% CI-88%, 98%) in fetuses, and 28% (95% CI-13%, 47%) and 64% (95% CI-23%, 94%) in children and adults, respectively; however the published data is limited to small, heterogenous and poorly designed studies. Insufficient data is available on acceptability and economic evaluation of post-mortem MR imaging. Well designed, large, prospective studies are required to evaluate the accuracy of post-mortem MR imaging, before it can be offered as a clinical tool.

  18. DOE Standard: Fire protection design criteria

    International Nuclear Information System (INIS)

    1999-07-01

    The development of this Standard reflects the fact that national consensus standards and other design criteria do not comprehensively or, in some cases, adequately address fire protection issues at DOE facilities. This Standard provides supplemental fire protection guidance applicable to the design and construction of DOE facilities and site features (such as water distribution systems) that are also provided for fire protection. It is intended to be used in conjunction with the applicable building code, National Fire Protection Association (NFPA) Codes and Standards, and any other applicable DOE construction criteria. This Standard replaces certain mandatory fire protection requirements that were formerly in DOE 5480.7A, ''Fire Protection'', and DOE 6430.1A, ''General Design Criteria''. It also contains the fire protection guidelines from two (now canceled) draft standards: ''Glove Box Fire Protection'' and ''Filter Plenum Fire Protection''. (Note: This Standard does not supersede the requirements of DOE 5480.7A and DOE 6430.1A where these DOE Orders are currently applicable under existing contracts.) This Standard, along with the criteria delineated in Section 3, constitutes the basic criteria for satisfying DOE fire and life safety objectives for the design and construction or renovation of DOE facilities

  19. On melting criteria for complex plasma

    International Nuclear Information System (INIS)

    Klumov, Boris A

    2011-01-01

    The present paper considers melting criteria for a plasma crystal discovered in dust plasma in 1994. Separate discussions are devoted to three-dimensional (3D) and two-dimensional (2D) systems. In the 3D case, melting criteria are derived based on the properties of local order in a system of microparticles. The order parameters are constructed from the cumulative distributions of the microparticle probability distributions as functions of various rotational invariants. The melting criteria proposed are constructed using static information on microparticle positions: a few snapshots of the system that allow for the determination of particle coordinates are enough to determine the phase state of the system. It is shown that criteria obtained in this way describe well the melting and premelting of 3D complex plasmas. In 2D systems, a system of microparticles interacting via a screened Coulomb (i.e., Debye-Hueckel or Yukawa) potential is considered as an example, using molecular dynamics simulations. A number of new order parameters characterizing the melting of 2D complex plasmas are proposed. The order parameters and melting criteria proposed for 2D and 3D complex plasmas can be applied to other systems as well. (methodological notes)

  20. Ear Infection Treatment Shouldn't Be Shortened

    Science.gov (United States)

    ... treatments might also reduce other side effects. A new NIH-funded study provides some answers—at least for children under age 2. The study enrolled 520 children, ages 6 to 23 months, who had middle-ear infections diagnosed using stringent criteria. Kids were ...

  1. Modern dimensioning criteria for pressure vessels

    International Nuclear Information System (INIS)

    Roche, Roland.

    1975-01-01

    Some ideas on modern dimensioning criteria are given and their advantages with regard to both safety and economy are shown. In general these criteria result from considerations on possible damage to the apparatus in service and the modes of breakdown liable to follow. They are general enough to allow for a variety of dimensioning methods both experimental and theoretical, with special reference to modern computerized digital analysis techniques. As a practical example however some notions are given on the simplest means of computing dimensions in accordance with these criteria [fr

  2. Separability criteria for genuine multiparticle entanglement

    NARCIS (Netherlands)

    Guhne, O.; Seevinck, M.P.|info:eu-repo/dai/nl/304847399

    2010-01-01

    We present a method to derive separability criteria for different classes of multiparticle entanglement, especially genuine multiparticle entanglement. The resulting criteria are necessary and sufficient for certain families of states. This, for example, completely solves the problem of classifying

  3. Separability Criteria for Genuine Multiparticle Entanglement

    NARCIS (Netherlands)

    Guehne, O.; Seevinck, M.P.

    2010-01-01

    We present a method to derive separability criteria for different classes of multiparticle entanglement, especially genuine multiparticle entanglement. The resulting criteria are necessary and sufficient for certain families of states. This, for example, completely solves the problem of classifying

  4. Evaluating Dependence Criteria for Caffeine.

    Science.gov (United States)

    Striley, Catherine L W; Griffiths, Roland R; Cottler, Linda B

    2011-12-01

    Background: Although caffeine is the most widely used mood-altering drug in the world, few studies have operationalized and characterized Diagnostic and Statistical Manual IV (DSM-IV) substance dependence criteria applied to caffeine. Methods: As a part of a nosological study of substance use disorders funded by the National Institute on Drug Abuse, we assessed caffeine use and dependence symptoms among high school and college students, drug treatment patients, and pain clinic patients who reported caffeine use in the last 7 days and also reported use of alcohol, nicotine, or illicit drugs within the past year ( n =167). Results: Thirty-five percent met the criteria for dependence when all seven of the adopted DSM dependence criteria were used. Rates of endorsement of several of the most applicable diagnostic criteria were as follows: 26% withdrawal, 23% desire to cut down or control use, and 44% continued use despite harm. In addition, 34% endorsed craving, 26% said they needed caffeine to function, and 10% indicated that they talked to a physician or counselor about problems experienced with caffeine. There was a trend towards increased caffeine dependence among those dependent on nicotine or alcohol. Within a subgroup that had used caffeine, alcohol, and nicotine in the past year, 28% fulfilled criteria for caffeine dependence compared to 50% for alcohol and 80% for nicotine. Conclusion: The present study adds to a growing literature suggesting the reliability, validity, and clinical utility of the caffeine dependence diagnosis. Recognition of caffeine dependence in the DSM-V may be clinically useful.

  5. Reliability criteria for voltage stability

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Carson W; Silverstein, Brian L [Bonneville Power Administration, Portland, OR (United States)

    1994-12-31

    In face of costs pressures, there is need to allocate scare resources more effectively in order to achieve voltage stability. This naturally leads to development of probabilistic criteria and notions of rick management. In this paper it is presented a discussion about criteria for long term voltage stability limited to the case in which the time frames are topically several minutes. (author) 14 refs., 1 fig.

  6. Dismissal: Important criteria in managerial decision-making

    Directory of Open Access Journals (Sweden)

    Fabricio Stocker

    2018-04-01

    Full Text Available Knowledge about dismissal decision-making, particularly concerning the criteria used by managers in choosing who will be dismissed and why, is scarce. Considering the implications of such decisions for organizations and society, in this paper, we identify the seven most frequently used criteria in dismissal decisions and examine their importance for managers. We collected data through a survey among 385 managers and used the rational ranking and the multicriteria Analytic Hierarchy Process (AHP to analyze them. The results show that commitment, performance records, and trust have the greatest impact on the dismissal decision, whereas interpersonal relationship, growth potential, and professional experience are considered secondary criteria. These results contribute to extending our knowledge about dismissal decisions and showing the most relevant criteria in these choices and the relevance assigned to each of the criteria so that greater transparency can be achieved.

  7. An objective approach to determining criteria weights

    Directory of Open Access Journals (Sweden)

    Milić R. Milićević

    2012-01-01

    Full Text Available This paper presents an objective approach to determining criteria weights that can be successfully used in multiple criteria models. The methods of entropy, CRITIC and FANMA are presented in this paper as well as a possible combination of the methods of objective and subjective approaches. Although based on different theoretical settings, and therefore with different algorithms of realization, all methods have a decision matrix as a starting point. An objective approach to determining the weight of criteria eliminates the negative impacts of a decision maker on criteria weights as well as on the final solution of multicriteria problems. The main aim of this paper is to systematize description procedures as a kind of help when encountering a problem of determining the criteria weights for solving multicriteria tasks. A possibility of the method application is shown in a numerical example.

  8. Qualitative vs. quantitative atopic dermatitis criteria

    DEFF Research Database (Denmark)

    Andersen, R M; Thyssen, J P; Maibach, H I

    2016-01-01

    This review summarizes historical aspects, clinical expression and pathophysiology leading to coining of the terms atopy and atopic dermatitis, current diagnostic criteria and further explore the possibility of developing quantitative diagnostic criteria of atopic dermatitis (AD) based on the imp...

  9. 29 CFR 1904.4 - Recording criteria.

    Science.gov (United States)

    2010-07-01

    ... criteria. (Needlestick and sharps injury cases, tuberculosis cases, hearing loss cases, medical removal... Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR RECORDING AND REPORTING OCCUPATIONAL INJURIES AND ILLNESSES Recordkeeping Forms and Recording Criteria § 1904.4...

  10. Stringent constraints on the dark matter annihilation cross section from subhalo searches with the Fermi Gamma-Ray Space Telescope

    Energy Technology Data Exchange (ETDEWEB)

    Berlin, Asher; Hooper, Dan

    2014-01-01

    The dark matter halo of the Milky Way is predicted to contain a very large number of smaller subhalos. As a result of the dark matter annihilations taking place within such objects, the most nearby and massive subhalos could appear as point-like or spatially extended gamma-ray sources, without observable counterparts at other wavelengths. In this paper, we use the results of the Aquarius simulation to predict the distribution of nearby subhalos, and compare this to the characteristics of the unidentified gamma-ray sources observed by the Fermi Gamma-Ray Space Telescope. Focusing on the brightest high latitude sources, we use this comparison to derive limits on the dark matter annihilation cross section. For dark matter particles lighter than ~200 GeV, the resulting limits are the strongest obtained to date, being modestly more stringent than those derived from observations of dwarf galaxies or the Galactic Center. We also derive independent limits based on the lack of unidentified gamma-ray sources with discernible spatial extension, but these limits are a factor of ~2-10 weaker than those based on point-like subhalos. Lastly, we note that four of the ten brightest high-latitude sources exhibit a similar spectral shape, consistent with 30-60 GeV dark matter particles annihilating to b quarks with an annihilation cross section on the order of sigma v ~ (5-10) x 10^-27 cm^3/s, or 8-10 GeV dark matter particles annihilating to taus with sigma v ~ (2.0-2.5) x 10^-27 cm^3/s.

  11. Primary progressive multiple sclerosis diagnostic criteria: a reappraisal.

    Science.gov (United States)

    Montalban, X; Sastre-Garriga, J; Filippi, M; Khaleeli, Z; Téllez, N; Vellinga, M M; Tur, C; Brochet, B; Barkhof, F; Rovaris, M; Miller, D H; Polman, C H; Rovira, A; Thompson, A J

    2009-12-01

    The diagnostic criteria used in primary progressive (PP) and relapsing-remitting (RR) multiple sclerosis (MS) show substantial differences. This introduces complexity in the diagnosis of MS which could be resolved if these criteria could be unified in terms of the requirements for dissemination in space (DIS). The aim of this study was to assess whether a single algorithm may be used to demonstrate DIS in all forms of MS. Five sets of RRMS criteria for DIS were applied to a cohort of 145 patients with established PPMS (mean disease duration: 11 years - PPMS-1): C1: Barkhof-Tintoré (as in 2005 McDonald's criteria); C2: Swanton et al. (as in JNNP 2006); C3: presence of oligoclonal bands plus two lesions (as in McDonald's criteria); C4 and C5: a two-step approach was also followed (patients not fulfilling C1 or C2 were then assessed for C3). Two sets of PPMS criteria for DIS were applied: C6: Thompson et al. (as in 2001 McDonald's criteria); C7: 2005 McDonald criteria. A second sample of 55 patients with less than 5 years of disease duration (PPMS-2) was also analysed using an identical approach. For PPMS-1/PPMS-2, fulfilment was: C1:73.8%/66.7%; C2:72.1%/59.3%; C3:89%/79.2%; C4:96%/92.3%; C5:96%/85.7%; C6:85.8%/78.7%; C7:91%/80.4%. Levels of fulfilment suggest that the use of a single set of criteria for DIS in RRMS and PPMS might be feasible, and reinforce the added value of cerebrospinal fluid (CSF) findings to increase fulfilment in PPMS. Unification of the DIS criteria for both RRMS and PPMS could be considered in further revisions of the MS diagnostic criteria.

  12. MR accuracy and arthroscopic incidence of meniscal radial tears

    Energy Technology Data Exchange (ETDEWEB)

    Magee, Thomas; Shapiro, Marc; Williams, David [Department of Radiology, Neuroimaging Institute, 27 East Hibiscus Blvd., Melbourne, FL 32901 (United States)

    2002-12-01

    A meniscal radial tear is a vertical tear that involves the inner meniscal margin. The tear is most frequent in the middle third of the lateral meniscus and may extend outward in any direction. We report (1) the arthroscopic incidence of radial tears, (2) MR signs that aid in the detection of radial tears and (3) our prospective accuracy in detection of radial tears. Design and patients. Three musculoskeletal radiologists prospectively read 200 consecutive MR examinations of the knee that went on to arthroscopy by one orthopedic surgeon. MR images were assessed for location and MR characteristics of radial tears. MR criteria used for diagnosis of a radial tear were those outlined by Tuckman et al.: truncation, abnormal morphology and/or lack of continuity or absence of the meniscus on one or more MR images. An additional criterion used was abnormal increased signal in that area on fat-saturated proton density or T2-weighted coronal and sagittal images. Prospective MR readings were correlated with the arthroscopic findings.Results. Of the 200 consecutive knee arthroscopies, 28 patients had radial tears reported arthroscopically (14% incidence). MR readings prospectively demonstrated 19 of the 28 radial tears (68% sensitivity) when the criteria for diagnosis of a radial tear were truncation or abnormal morphology of the meniscus. With the use of the additional criterion of increased signal in the area of abnormal morphology on fat-saturated T2-weighted or proton density weighted sequences, the prospective sensitivity was 25 of 28 radial tears (89% sensitivity). There were no radial tears described in MR reports that were not demonstrated on arthroscopy (i.e., there were no false positive MR readings of radial tears in these 200 patients). Radial tears are commonly seen at arthroscopy. There was a 14% incidence in this series of 200 patients who underwent arthroscopy. Prospective detection of radial tears was 68% as compared with arthroscopy when the criteria as

  13. MR accuracy and arthroscopic incidence of meniscal radial tears

    International Nuclear Information System (INIS)

    Magee, Thomas; Shapiro, Marc; Williams, David

    2002-01-01

    A meniscal radial tear is a vertical tear that involves the inner meniscal margin. The tear is most frequent in the middle third of the lateral meniscus and may extend outward in any direction. We report (1) the arthroscopic incidence of radial tears, (2) MR signs that aid in the detection of radial tears and (3) our prospective accuracy in detection of radial tears. Design and patients. Three musculoskeletal radiologists prospectively read 200 consecutive MR examinations of the knee that went on to arthroscopy by one orthopedic surgeon. MR images were assessed for location and MR characteristics of radial tears. MR criteria used for diagnosis of a radial tear were those outlined by Tuckman et al.: truncation, abnormal morphology and/or lack of continuity or absence of the meniscus on one or more MR images. An additional criterion used was abnormal increased signal in that area on fat-saturated proton density or T2-weighted coronal and sagittal images. Prospective MR readings were correlated with the arthroscopic findings.Results. Of the 200 consecutive knee arthroscopies, 28 patients had radial tears reported arthroscopically (14% incidence). MR readings prospectively demonstrated 19 of the 28 radial tears (68% sensitivity) when the criteria for diagnosis of a radial tear were truncation or abnormal morphology of the meniscus. With the use of the additional criterion of increased signal in the area of abnormal morphology on fat-saturated T2-weighted or proton density weighted sequences, the prospective sensitivity was 25 of 28 radial tears (89% sensitivity). There were no radial tears described in MR reports that were not demonstrated on arthroscopy (i.e., there were no false positive MR readings of radial tears in these 200 patients). Radial tears are commonly seen at arthroscopy. There was a 14% incidence in this series of 200 patients who underwent arthroscopy. Prospective detection of radial tears was 68% as compared with arthroscopy when the criteria as

  14. Examining those Meeting IOM Criteria Versus IOM Plus Fibromyalgia.

    Science.gov (United States)

    Jason, Leonard A; McManimen, Stephanie; Sunnquist, Madison; Newton, Julia L; Strand, Elin Bolle

    2017-01-01

    The Institute of Medicine (IOM) recently developed clinical criteria for chronic fatigue syndrome (CFS). There might be additional criteria that could select a more homogenous and impaired group of patients, particularly those with pain. The current study focused on criteria which involved meeting the four IOM criteria, excluding medical and psychiatric co-morbidities, along with having fibromyalgia (FM). Findings indicated that those meeting the IOM clinical criteria plus FM were more impaired on a wide variety of symptoms and functional areas than those meeting on the IOM criteria or those with just 6 months of fatigue. The implications of using such research criteria are discussed.

  15. NWTS program criteria for mined geologic disposal of nuclear waste: repository performance and development criteria. Public draft

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-07-01

    This document, DOE/NWTS-33(3) is one of a series of documents to establish the National Waste Terminal Storage (NWTS) program criteria for mined geologic disposal of high-level radioactive waste. For both repository performance and repository development it delineates the criteria for design performance, radiological safety, mining safety, long-term containment and isolation, operations, and decommissioning. The US Department of Energy will use these criteria to guide the development of repositories to assist in achieving performance and will reevaluate their use when the US Nuclear Regulatory Commission issues radioactive waste repository rules.

  16. NWTS program criteria for mined geologic disposal of nuclear waste: repository performance and development criteria. Public draft

    International Nuclear Information System (INIS)

    1982-07-01

    This document, DOE/NWTS-33(3) is one of a series of documents to establish the National Waste Terminal Storage (NWTS) program criteria for mined geologic disposal of high-level radioactive waste. For both repository performance and repository development it delineates the criteria for design performance, radiological safety, mining safety, long-term containment and isolation, operations, and decommissioning. The US Department of Energy will use these criteria to guide the development of repositories to assist in achieving performance and will reevaluate their use when the US Nuclear Regulatory Commission issues radioactive waste repository rules

  17. Hybrid multiple criteria decision-making methods

    DEFF Research Database (Denmark)

    Zavadskas, Edmundas Kazimieras; Govindan, K.; Antucheviciene, Jurgita

    2016-01-01

    Formal decision-making methods can be used to help improve the overall sustainability of industries and organisations. Recently, there has been a great proliferation of works aggregating sustainability criteria by using diverse multiple criteria decision-making (MCDM) techniques. A number of revi...

  18. Radiation protection criteria in the long-range view

    International Nuclear Information System (INIS)

    Snihs, J.O.; Bergman, C.

    1989-01-01

    The report presents by way of introduction radiation protection criteria applied to radiological activities and to disposal of low-level and intermediate-level radioactive waste. In these cases it is primarily short-range views that are relevant, up to a few thousand years as a maximum. In the case of high-level wastes where the views may extend to more than hundreds of thousands years, there are not for the present any equally well stablished criteria. Based upon preliminary results from a Nordic team for criteria for high-level radioactive wastes, dose estimates in the long-range view and alternative assessment criteria are discussed. Proposals are also presented for 12 criteria that may be applicable. As the work is not yet finshed, the criteria are however merely preliminary

  19. Containment penetration design criteria and implementation

    International Nuclear Information System (INIS)

    Perry, R.F.; Rigamonti, G.; Dainora, J.

    1975-01-01

    A rational design criteria is presented which serves as a basis for the design and analysis of containment piping penetrations. The criteria includes the effect of temperature as well as mechanical loads for the full range of plant conditions. With this criteria various penetration flued head designs have been compared and optimization achieved. Sleeve wall dimensions and containment loads have been determined without reference to piping configuration. An interaction theory which allows the implementation of the criteria for the determination of design loads and minimum sleeve wall thickness. The interaction theory developed applies to elastic-perfectly plastic cylinders (pipes and sleeves) and accounts for the simultaneous load resultants of transverse shear force, bending moment, torsional moment, and axial force in addition to internal pipe pressure. Application of the theory developed to the determination of sleeve thickness and containment design loads is presented in detail. (Auth.)

  20. Improving coding accuracy in an academic practice.

    Science.gov (United States)

    Nguyen, Dana; O'Mara, Heather; Powell, Robert

    2017-01-01

    Practice management has become an increasingly important component of graduate medical education. This applies to every practice environment; private, academic, and military. One of the most critical aspects of practice management is documentation and coding for physician services, as they directly affect the financial success of any practice. Our quality improvement project aimed to implement a new and innovative method for teaching billing and coding in a longitudinal fashion in a family medicine residency. We hypothesized that implementation of a new teaching strategy would increase coding accuracy rates among residents and faculty. Design: single group, pretest-posttest. military family medicine residency clinic. Study populations: 7 faculty physicians and 18 resident physicians participated as learners in the project. Educational intervention: monthly structured coding learning sessions in the academic curriculum that involved learner-presented cases, small group case review, and large group discussion. overall coding accuracy (compliance) percentage and coding accuracy per year group for the subjects that were able to participate longitudinally. Statistical tests used: average coding accuracy for population; paired t test to assess improvement between 2 intervention periods, both aggregate and by year group. Overall coding accuracy rates remained stable over the course of time regardless of the modality of the educational intervention. A paired t test was conducted to compare coding accuracy rates at baseline (mean (M)=26.4%, SD=10%) to accuracy rates after all educational interventions were complete (M=26.8%, SD=12%); t24=-0.127, P=.90. Didactic teaching and small group discussion sessions did not improve overall coding accuracy in a residency practice. Future interventions could focus on educating providers at the individual level.

  1. Floorball game skills (evaluation criteria)

    OpenAIRE

    Chlumský, Marek

    2013-01-01

    Title: Playing skills in floorball (evaluation criteria). Target: To create a list of playing skills which an ideal player should demonstrate. Find and verify the evaluation criteria of these skills and inspire trainers to develop these skills in the best way. Methods: Informal interviews, individually structured interviews, analysis and verification of data, pilot testing. Results: Defined playing skills in floorball, developed scale of values of floorball playing skills, creation of exercis...

  2. Geoscientific evaluation factors and criteria for siting and site evaluation. Progress report

    International Nuclear Information System (INIS)

    Stroem, A.; Ericsson, Lars O.; Svemar, C.; Almen, K.E.; Andersson, Johan

    1999-03-01

    thereby involved. Requirements and preferences regarding the deep repository, and thereby the rock, are primarily formulated with respect to function and not directly for individual parameter values. In a similar manner the evaluation factors have been arranged per geoscientific discipline. A geoscientific parameter that can be measured or estimated in site investigations is considered to be a suitable evaluation factor if one of the following conditions is fulfilled: a direct requirement or an essential preference has been formulated for the parameter, or a the parameter is expected to have a great influence on the result of one or more important function analyses. Based on a preliminary list of possible evaluation factors, the level of knowledge that can or should be reached after the feasibility study, site investigation and detailed characterization have been completed is also discussed. It is not reasonable to designate a geoscientific parameter as an evaluation factor if the parameter cannot be measured or estimated with sufficient accuracy. Criteria for site evaluation will also be determined in the future work. When it comes to repository performance, criteria consist of indicative values or value ranges of outcomes of performance assessments. The criteria can be changed during the course of the siting work as the information available on the sites changes. But requirements and preferences remain the same. Even though the overall evaluation of the suitability of the sites is determined within the framework of an integrated safety assessment and an integrated construction analysis, the specified criteria should provide good guidance regarding the results of such an integrated assessment/analysis

  3. Geoscientific evaluation factors and criteria for siting and site evaluation. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Stroem, A.; Ericsson, Lars O.; Svemar, C. [Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden); Almen, K.E. [KEA GEO-konsult AB (Sweden); Andersson, Johan [Golder Grundteknik KB (Sweden)

    1999-03-01

    thereby involved. Requirements and preferences regarding the deep repository, and thereby the rock, are primarily formulated with respect to function and not directly for individual parameter values. In a similar manner the evaluation factors have been arranged per geoscientific discipline. A geoscientific parameter that can be measured or estimated in site investigations is considered to be a suitable evaluation factor if one of the following conditions is fulfilled: a direct requirement or an essential preference has been formulated for the parameter, or a the parameter is expected to have a great influence on the result of one or more important function analyses. Based on a preliminary list of possible evaluation factors, the level of knowledge that can or should be reached after the feasibility study, site investigation and detailed characterization have been completed is also discussed. It is not reasonable to designate a geoscientific parameter as an evaluation factor if the parameter cannot be measured or estimated with sufficient accuracy. Criteria for site evaluation will also be determined in the future work. When it comes to repository performance, criteria consist of indicative values or value ranges of outcomes of performance assessments. The criteria can be changed during the course of the siting work as the information available on the sites changes. But requirements and preferences remain the same. Even though the overall evaluation of the suitability of the sites is determined within the framework of an integrated safety assessment and an integrated construction analysis, the specified criteria should provide good guidance regarding the results of such an integrated assessment/analysis 14 refs, figs, tabs

  4. 42 CFR 456.5 - Evaluation criteria.

    Science.gov (United States)

    2010-10-01

    ...) MEDICAL ASSISTANCE PROGRAMS UTILIZATION CONTROL General Provisions § 456.5 Evaluation criteria. The agency must establish and use written criteria for evaluating the appropriateness and quality of Medicaid services. This section does not apply to services in hospitals and mental hospitals. For these facilities...

  5. [Primary childhood vasculitis new classification criteria

    DEFF Research Database (Denmark)

    Herlin, T.; Nielsen, Susan

    2008-01-01

    Primary vasculitis is seen in both adults and children, but some of the diseases like Kawasaki disease occur primarily in children. The Chapel Hill Classification Criteria for primary vasculitis refers to the size of vessels but has not been validated in children. Recently, new criteria...

  6. Medicalising normality? Using a simulated dataset to assess the performance of different diagnostic criteria of HIV-associated cognitive impairment

    Science.gov (United States)

    De Francesco, Davide; Leech, Robert; Sabin, Caroline A.; Winston, Alan

    2018-01-01

    Objective The reported prevalence of cognitive impairment remains similar to that reported in the pre-antiretroviral therapy era. This may be partially artefactual due to the methods used to diagnose impairment. In this study, we evaluated the diagnostic performance of the HIV-associated neurocognitive disorder (Frascati criteria) and global deficit score (GDS) methods in comparison to a new, multivariate method of diagnosis. Methods Using a simulated ‘normative’ dataset informed by real-world cognitive data from the observational Pharmacokinetic and Clinical Observations in PeoPle Over fiftY (POPPY) cohort study, we evaluated the apparent prevalence of cognitive impairment using the Frascati and GDS definitions, as well as a novel multivariate method based on the Mahalanobis distance. We then quantified the diagnostic properties (including positive and negative predictive values and accuracy) of each method, using bootstrapping with 10,000 replicates, with a separate ‘test’ dataset to which a pre-defined proportion of ‘impaired’ individuals had been added. Results The simulated normative dataset demonstrated that up to ~26% of a normative control population would be diagnosed with cognitive impairment with the Frascati criteria and ~20% with the GDS. In contrast, the multivariate Mahalanobis distance method identified impairment in ~5%. Using the test dataset, diagnostic accuracy [95% confidence intervals] and positive predictive value (PPV) was best for the multivariate method vs. Frascati and GDS (accuracy: 92.8% [90.3–95.2%] vs. 76.1% [72.1–80.0%] and 80.6% [76.6–84.5%] respectively; PPV: 61.2% [48.3–72.2%] vs. 29.4% [22.2–36.8%] and 33.9% [25.6–42.3%] respectively). Increasing the a priori false positive rate for the multivariate Mahalanobis distance method from 5% to 15% resulted in an increase in sensitivity from 77.4% (64.5–89.4%) to 92.2% (83.3–100%) at a cost of specificity from 94.5% (92.8–95.2%) to 85.0% (81.2–88

  7. Analysis and research of influence factors ranking of fuzzy language translation accuracy in literary works based on catastrophe progression method

    Directory of Open Access Journals (Sweden)

    Wei Dong

    2017-02-01

    Full Text Available This paper researches the problem of decline in translation accuracy caused by language “vagueness” in literary translation, and proposes to use the catastrophe model for importance ranking of various factors affecting the fuzzy language translation accuracy in literary works, and finally gives out the order of factors to be considered before translation. The multi-level evaluation system can be used to construct the relevant catastrophe progression model, and the normalization formula can be used to calculate the relative membership degree of each system and evaluation index, and make evaluation combined with the evaluation criteria table. The results show that, in the fuzzy language translation, in order to improve the translation accuracy, there is a need to consider the indicators ranking: A2 fuzzy language context → A1 words attribute → A3 specific meaning of digital words; B2 fuzzy semantics, B3 blur color words → B1 multiple meanings of words → B4 fuzzy digital words; C3 combination with context and cultural background, C4 specific connotation of color words → C1 combination with words emotion, C2 selection of words meaning → C5 combination with digits and language background.

  8. Multiple sequence alignment accuracy and phylogenetic inference.

    Science.gov (United States)

    Ogden, T Heath; Rosenberg, Michael S

    2006-04-01

    Phylogenies are often thought to be more dependent upon the specifics of the sequence alignment rather than on the method of reconstruction. Simulation of sequences containing insertion and deletion events was performed in order to determine the role that alignment accuracy plays during phylogenetic inference. Data sets were simulated for pectinate, balanced, and random tree shapes under different conditions (ultrametric equal branch length, ultrametric random branch length, nonultrametric random branch length). Comparisons between hypothesized alignments and true alignments enabled determination of two measures of alignment accuracy, that of the total data set and that of individual branches. In general, our results indicate that as alignment error increases, topological accuracy decreases. This trend was much more pronounced for data sets derived from more pectinate topologies. In contrast, for balanced, ultrametric, equal branch length tree shapes, alignment inaccuracy had little average effect on tree reconstruction. These conclusions are based on average trends of many analyses under different conditions, and any one specific analysis, independent of the alignment accuracy, may recover very accurate or inaccurate topologies. Maximum likelihood and Bayesian, in general, outperformed neighbor joining and maximum parsimony in terms of tree reconstruction accuracy. Results also indicated that as the length of the branch and of the neighboring branches increase, alignment accuracy decreases, and the length of the neighboring branches is the major factor in topological accuracy. Thus, multiple-sequence alignment can be an important factor in downstream effects on topological reconstruction.

  9. Accuracy Limitations in Optical Linear Algebra Processors

    Science.gov (United States)

    Batsell, Stephen Gordon

    1990-01-01

    One of the limiting factors in applying optical linear algebra processors (OLAPs) to real-world problems has been the poor achievable accuracy of these processors. Little previous research has been done on determining noise sources from a systems perspective which would include noise generated in the multiplication and addition operations, noise from spatial variations across arrays, and from crosstalk. In this dissertation, we propose a second-order statistical model for an OLAP which incorporates all these system noise sources. We now apply this knowledge to determining upper and lower bounds on the achievable accuracy. This is accomplished by first translating the standard definition of accuracy used in electronic digital processors to analog optical processors. We then employ our second-order statistical model. Having determined a general accuracy equation, we consider limiting cases such as for ideal and noisy components. From the ideal case, we find the fundamental limitations on improving analog processor accuracy. From the noisy case, we determine the practical limitations based on both device and system noise sources. These bounds allow system trade-offs to be made both in the choice of architecture and in individual components in such a way as to maximize the accuracy of the processor. Finally, by determining the fundamental limitations, we show the system engineer when the accuracy desired can be achieved from hardware or architecture improvements and when it must come from signal pre-processing and/or post-processing techniques.

  10. Redefining design criteria for Pu-238 gloveboxes

    International Nuclear Information System (INIS)

    Acosta, S.V.

    1998-01-01

    Enclosures for confinement of special nuclear materials (SNM) have evolved into the design of gloveboxes. During the early stages of glovebox technology, established practices and process operation requirements defined design criteria. Proven boxes that performed and met or exceeded process requirements in one group or area, often could not be duplicated in other areas or processes, and till achieve the same success. Changes in materials, fabrication and installation methods often only met immediate design criteria. Standardization of design criteria took a big step during creation of ''Special-Nuclear Materials R and D Laboratory Project, Glovebox standards''. The standards defined design criteria for every type of process equipment in its most general form. Los Alamos National Laboratory (LANL) then and now has had great success with Pu-238 processing. However with ever changing Environment Safety and Health (ES and H) requirements and Ta-55 Facility Configuration Management, current design criteria are forced to explore alternative methods of glovebox design fabrication and installation. Pu-238 fuel processing operations in the Power Source Technologies Group have pushed the limitations of current design criteria. More than half of Pu-238 gloveboxes are being retrofitted or replaced to perform the specific fuel process operations. Pu-238 glovebox design criteria are headed toward process designed single use glovebox and supporting line gloveboxes. Gloveboxes that will house equipment and processes will support TA-55 Pu-238 fuel processing needs into the next century and extend glovebox expected design life

  11. MULTI-CRITERIA ANALYSIS APPLIED TO LANDSLIDE SUSCEPTIBILITY MAPPING

    Directory of Open Access Journals (Sweden)

    Mariana Madruga de Brito

    2017-10-01

    Full Text Available This paper presents the application of a multi-criteria analysis (MCA tool for landslide susceptibility assessment in Porto Alegre municipality, southern Brazil. A knowledge driven approach was used, aiming to ensure an optimal use of the available information. The landslide conditioning factors considered were slope, lithology, flow accumulation and distance from lineaments. Standardization of these factors was done through fuzzy membership functions, and evaluation of their relative importance for landslide predisposition was supported by the analytic hierarchy process (AHP, based on local expert knowledge. Finally, factors were integrated in a GIS environment using the weighted linear combination (WLC method. For validation, an inventory, including 107 landslide points recorded between 2007 and 2013 was used. Results indicated that 8.2% (39.40 km² of the study area are highly and very highly susceptible to landslides. An overall accuracy of 95% was found, with an area under the receiver operating characteristic (ROC curve of 0.960. Therefore, the resulting map can be regarded as useful for monitoring landslide-prone areas. Based on the findings, it is concluded that the proposed method is effective for susceptibility assessment since it yielded meaningful results and does not require extensive input data.

  12. Quantitative accuracy assessment of thermalhydraulic code predictions with SARBM

    International Nuclear Information System (INIS)

    Prosek, A.

    2001-01-01

    In recent years, the nuclear reactor industry has focused significant attention on nuclear reactor systems code accuracy and uncertainty issues. A few methods suitable to quantify code accuracy of thermalhydraulic code calculations were proposed and applied in the past. In this study a Stochastic Approximation Ratio Based Method (SARBM) was adapted and proposed for accuracy quantification. The objective of the study was to qualify the SARBM. The study compare the accuracy obtained by SARBM with the results obtained by widely used Fast Fourier Transform Based Method (FFTBM). The methods were applied to RELAP5/MOD3.2 code calculations of various BETHSY experiments. The obtained results showed that the SARBM was able to satisfactorily predict the accuracy of the calculated trends when visually comparing plots and comparing the results with the qualified FFTBM. The analysis also showed that the new figure-of-merit called accuracy factor (AF) is more convenient than stochastic approximation ratio for combining single variable accuracy's into total accuracy. The accuracy results obtained for the selected tests suggest that the acceptability factors for the SAR method were reasonably defined. The results also indicate that AF is a useful quantitative measure of accuracy.(author)

  13. Risk based seismic design criteria

    International Nuclear Information System (INIS)

    Kennedy, R.P.

    1999-01-01

    In order to develop a risk based seismic design criteria the following four issues must be addressed: (1) What target annual probability of seismic induced unacceptable performance is acceptable? (2) What minimum seismic margin is acceptable? (3) Given the decisions made under Issues 1 and 2, at what annual frequency of exceedance should the safe-shutdown-earthquake (SSE) ground motion be defined? (4) What seismic design criteria should be established to reasonably achieve the seismic margin defined under Issue 2? The first issue is purely a policy decision and is not addressed in this paper. Each of the other three issues are addressed. Issues 2 and 3 are integrally tied together so that a very large number of possible combinations of responses to these two issues can be used to achieve the target goal defined under Issue 1. Section 2 lays out a combined approach to these two issues and presents three potentially attractive combined resolutions of these two issues which reasonably achieves the target goal. The remainder of the paper discusses an approach which can be used to develop seismic design criteria aimed at achieving the desired seismic margin defined in resolution of Issue 2. Suggestions for revising existing seismic design criteria to more consistently achieve the desired seismic margin are presented. (orig.)

  14. The accuracy of ultrasonography for the evaluation of portal hypertension in patients with cirrhosis: A systematic review

    International Nuclear Information System (INIS)

    Kim, Gaeun; Cho, Youn Zoo; Baik, Soon Koo; Kim, Moon Young; Hong, Won Ki; Kwon, Sang Ok

    2015-01-01

    Studies have presented conflicting results regarding the accuracy of ultrasonography (US) for diagnosing portal hypertension (PH). We sought to identify evidence in the literature regarding the accuracy of US for assessing PH in patients with liver cirrhosis. We conducted a systematic review by searching databases, including MEDLINE, EMBASE, and the Cochrane Library, for relevant studies. A total of 14 studies met our inclusion criteria. The US indices were obtained in the portal vein (n = 9), hepatic artery (n = 6), hepatic vein (HV) (n = 4) and other vessels. Using hepatic venous pressure gradient (HVPG) as the reference, the sensitivity (Se) and specificity (Sp) of the portal venous indices were 69-88% and 67-75%, respectively. The correlation coefficients between HVPG and the portal venous indices were approximately 0.296-0.8. No studies assess the Se and Sp of the hepatic arterial indices. The correlation between HVPG and the hepatic arterial indices ranged from 0.01 to 0.83. The Se and Sp of the hepatic venous indices were 75.9-77.8% and 81.8-100%, respectively. In particular, the Se and Sp of HV arrival time for clinically significant PH were 92.7% and 86.7%, respectively. A statistically significant correlation between HVPG and the hepatic venous indices was observed (0.545-0.649). Some US indices, such as HV, exhibited an increased accuracy for diagnosing PH. These indices may be useful in clinical practice for the detection of significant PH.

  15. The accuracy of ultrasonography for the evaluation of portal hypertension in patients with cirrhosis: A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gaeun; Cho, Youn Zoo; Baik, Soon Koo [College of Nursing, Research Institute for Nursing Science, Keimyung Univercity, Daegu (Korea, Republic of); Kim, Moon Young; Hong, Won Ki; Kwon, Sang Ok [Dept. of Internal Medicine, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju (Korea, Republic of)

    2015-04-15

    Studies have presented conflicting results regarding the accuracy of ultrasonography (US) for diagnosing portal hypertension (PH). We sought to identify evidence in the literature regarding the accuracy of US for assessing PH in patients with liver cirrhosis. We conducted a systematic review by searching databases, including MEDLINE, EMBASE, and the Cochrane Library, for relevant studies. A total of 14 studies met our inclusion criteria. The US indices were obtained in the portal vein (n = 9), hepatic artery (n = 6), hepatic vein (HV) (n = 4) and other vessels. Using hepatic venous pressure gradient (HVPG) as the reference, the sensitivity (Se) and specificity (Sp) of the portal venous indices were 69-88% and 67-75%, respectively. The correlation coefficients between HVPG and the portal venous indices were approximately 0.296-0.8. No studies assess the Se and Sp of the hepatic arterial indices. The correlation between HVPG and the hepatic arterial indices ranged from 0.01 to 0.83. The Se and Sp of the hepatic venous indices were 75.9-77.8% and 81.8-100%, respectively. In particular, the Se and Sp of HV arrival time for clinically significant PH were 92.7% and 86.7%, respectively. A statistically significant correlation between HVPG and the hepatic venous indices was observed (0.545-0.649). Some US indices, such as HV, exhibited an increased accuracy for diagnosing PH. These indices may be useful in clinical practice for the detection of significant PH.

  16. Forecast Accuracy Uncertainty and Momentum

    OpenAIRE

    Bing Han; Dong Hong; Mitch Warachka

    2009-01-01

    We demonstrate that stock price momentum and earnings momentum can result from uncertainty surrounding the accuracy of cash flow forecasts. Our model has multiple information sources issuing cash flow forecasts for a stock. The investor combines these forecasts into an aggregate cash flow estimate that has minimal mean-squared forecast error. This aggregate estimate weights each cash flow forecast by the estimated accuracy of its issuer, which is obtained from their past forecast errors. Mome...

  17. The usage of crash-safety simulation software in the automotive industry

    NARCIS (Netherlands)

    Verschut, R.; Hyun, Y.W.

    1998-01-01

    The last 10 years the safety issue for road vehicles has become increasingly important. Not only regulations but also NCAP testing force manufacturers to develop restraint systems which can meet the stringent criteria set by these procedures. Because of the various safety requirements the

  18. Effects of streamlining cervical cancer screening the Dutch way: consequences of changes in the Dutch KOPAC-based follow-up protocol and consensus-based limitation of equivocal cytology

    DEFF Research Database (Denmark)

    Briët, Martijn C; Berger, Thomas H D; van Ballegooijen, Marjolein

    2010-01-01

    To analyze the impact of the 1995 revision of the Dutch cervical screening program guidelines (e.g., the introduction of more stringent criteria for cytologic diagnosis of atypical squamous cells of undetermined significance [ASCUS]) on the negative side effects of screening in Region West....

  19. Education Criteria for Performance Excellence, 2002.

    Science.gov (United States)

    National Inst. of Standards and Technology, Gaithersburg, MD.

    The education criteria presented in this guide are designed to help organizations use an integrated approach to organizational performance management that results in delivery of ever-improving value to students and stakeholders. Implementation of the criteria will contribute to improvement of education quality, improvement of overall…

  20. Who and Racist criteria on CT

    International Nuclear Information System (INIS)

    Servente, L.

    2012-01-01

    This presentation is about Who and Recist criteria on CT.These are rules to the evaluation of the solid tumors treatment response as well as different concepts of measurability criteria of blastic changes, target /non target lesions, adenopathies, lytic, cystic , non-measurable disease and progressive lesions

  1. Accuracy of F-DOPA PET and perfusion-MRI for differentiating radionecrotic from progressive brain metastases after radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Cicone, Francesco; Papa, Annalisa; Scopinaro, Francesco [Sant' Andrea Hospital, Rome (Italy). Unit of Nuclear Medicine; ' ' Sapienza' ' Univ., Rome (Italy). Dept. of Surgical and Medicine Sciences and Translational Medicine; Minniti, Giuseppe; Scaringi, Claudia; Maurizi Enrici, Riccardo [' ' Sapienza' ' Univ., Rome (Italy). Dept. of Surgical and Medicine Sciences and Translational Medicine; Sant' Andrea Hospital, Rome (Italy). Unit of Radiotherapy; Romano, Andrea; Tavanti, Francesca; Bozzao, Alessandro [Sant' Andrea Hospital, Rome (Italy). Unit of Neuroradiology; Rome Univ. (Italy). Dept. of Neurosciences, Mental Health and Sensory Organs (Ne.S.M.O.S.)

    2015-01-15

    We assessed the performance of 6-[{sup 18}F]-fluoro-l-3,4-dihydroxyphenylalanine (F-DOPA) PET for differentiating radionecrosis (RN) from tumour progression (PD) in a population of patients with brain metastases, treated with stereotactic radiosurgery. The accuracy of F-DOPA PET was compared with that of perfusion-weighted magnetic resonance (perfusion-MR). In 42 patients with a total of 50 brain metastases from various primaries F-DOPA PET/CT was performed because of suspected radiological progression at the site of previously irradiated brain metastasis. Several semiquantitative PET parameters were recorded, and their diagnostic accuracy was compared by receiver operating characteristic curve analyses. The diagnosis was established by either surgery or follow-up. A comparison was made between F-DOPA PET and perfusion-MR sequences acquired no more than 3 weeks apart. Definitive outcome was available in 46 of the 50 lesions (20 PD, 26 RN). Of the 46 lesions, 11 were surgically excised while in the remaining 35 lesions the diagnosis was established by radiological and clinical criteria. The best diagnostic performance was obtained using the semiquantitative PET parameter maximum lesion to maximum background uptake ratio (SUVL{sub max}/Bkgr{sub max}). With a cut-off value of 1.59, a sensitivity of 90 % and a specificity of 92.3 % were achieved in differentiating RN from PD lesions (accuracy 91.3 %). Relative cerebral blood volume (rCBV) derived from perfusion-MR was available for comparison in 37 of the 46 metastases. Overall accuracy of rCBV was lower than that of all semiquantitative PET parameters under study. The best differentiating rCBV cut-off value was 2.14; this yielded a sensitivity of 86.7 % and a specificity of 68.2 % (accuracy 75.6 %). F-DOPA PET is a highly accurate tool for differentiating RN from PD brain metastases after stereotactic radiosurgery. In this specific setting, F-DOPA PET seems to perform better than perfusion-MR. (orig.)

  2. Safety criteria for nuclear chemical plants

    International Nuclear Information System (INIS)

    Ball, P.W.; Curtis, L.M.

    1983-01-01

    Safety measures have always been required to limit the hazards due to accidental release of radioactive substances from nuclear power plants and chemical plants. The risk associated with the discharge of radioactive substances during normal operation has also to be kept acceptably low. BNFL (British Nuclear Fuels Ltd.) are developing risk criteria as targets for safe plant design and operation. The numerical values derived are compared with these criteria to see if plants are 'acceptably safe'. However, the criteria are not mandatory and may be exceeded if this can be justified. The risk assessments are subject to independent review and audit. The Nuclear Installations Inspectorate also has to pass the plants as safe. The assessment principles it uses are stated. The development of risk criteria for a multiplant site (nuclear chemical plants tend to be sited with many others which are related functionally) is discussed. This covers individual members of the general public, societal risks, risks to the workforce and external hazards. (U.K.)

  3. Strengths, Limitations, and Geographical Discrepancies in the Eligibility Criteria for Sport Participation in Young Patients With Congenital Heart Disease.

    Science.gov (United States)

    Cantinotti, Massimiliano; Giordano, Raffaele; Assanta, Nadia; Murzi, Bruno; Melo, Manuel; Franchi, Eliana; Crocetti, Maura; Iervasi, Giorgio; Kutty, Shelby

    2017-07-21

    Benefits of physical activity has been shown in children with congenital heart disease (CHD). In several forms of CHD, the risk of sudden death remains a major concern both for parents and clinicians, who in turn will have to consider the risk-benefit ratio of sport participation versus restriction. A literature search was performed within the National Library of Medicine using the keywords: Sport, CHD, and Eligibility. The search was further refined by adding the keywords: Children, Adult, and Criteria. Fifteen published studies evaluating sport eligibility criteria in CHD were included. Seven documents from various scientific societies have been published in the past decade but which of them should be adopted remains unclear. Our research highlighted accuracy and consistency of the latest documents; however, differences have emerged between the US and European recommendations. Eligibility criteria were consistent between countries for simple congenital heart defects, whereas there are discrepancies for borderline conditions including moderate valvular lesions and mild or moderate residual defects after CHD repair. Furthermore, some of the more severe defects were not evaluated. Multiple recommendations have been made for the same CHD, and cut-off values used to define disease severity have varied. Published eligibility criteria have mainly focused on competitive sports. Little attention was paid to recreational activities, and the psychosocial consequences of activity restriction were seldom evaluated. Comprehensive consensus recommendations for sport eligibility evaluating all CHD types and stages of repair are needed. These should include competitive and recreational activities, use standardized classifications to grade disease severity, and address the consequences of restriction.

  4. [Criteria of scientific validity in research].

    Science.gov (United States)

    Pelletier, Céline; Pagé, Ginette

    2002-03-01

    The purpose of this article is to present the evaluative criteria of qualitative and quantitative research. Philosophical foundations of positivism, postpositivism and constructivism are explored. Triangulation and crystallization expose the controversies about them. Finally, Lincoln and Guba criteria are retained for the evaluation of qualitative and quantitative research.

  5. Aspirational Model Teaching Criteria for Psychology

    Science.gov (United States)

    Richmond, Aaron S.; Boysen, Guy A.; Gurung, Regan A. R.; Tazeau, Yvette N.; Meyers, Steven A.; Sciutto, Mark J.

    2014-01-01

    In 2011, the Society for the Teaching of Psychology commissioned a presidential task force to document teaching criteria for model psychology teachers in undergraduate education. The resulting list of criteria reflects activities related to face-to-face course interaction and online teaching, training, and education; course design; implementation…

  6. Nuclear Fuel Safety Criteria Technical Review - Second edition

    International Nuclear Information System (INIS)

    Beck, Winfried; Blanpain, Patrick; Fuketa, Toyoshi; Gorzel, Andreas; Hozer, Zoltan; Kamimura, Katsuichiro; Koo, Yang-Hyun; Maertens, Dietmar; Nechaeva, Olga; Petit, Marc; Rehacek, Radomir; Rey-Gayo, Jose Maria; Sairanen, Risto; Sonnenburg, Heinz-Guenther; Valach, Mojmir; Waeckel, Nicolas; Yueh, Ken; Zhang, Jinzhao; Voglewede, John

    2012-01-01

    Most of the current nuclear fuel safety criteria were established during the 1960's and early 1970's. Although these criteria were validated against experiments with fuel designs available at that time, a number of tests were based on unirradiated fuels. Additional verification was performed as these designs evolved, but mostly with the aim of showing that the new designs adequately complied with existing criteria, and not to establish new limits. In 1996, the OECD Nuclear Energy Agency (NEA) reviewed existing fuel safety criteria, focusing on new fuel and core designs, new cladding materials and industry manufacturing processes. The results were published in the Nuclear Fuel Safety Criteria Technical Review of 2001. The NEA has since re-examined the criteria. A brief description of each criterion and its rationale are presented in this second edition, which will be of interest to both regulators and industry (fuel vendors, utilities)

  7. Risk acceptance criteria of the Nuclear Regulatory Authority

    International Nuclear Information System (INIS)

    Felizia, Eduardo R.

    2005-01-01

    This report describes some of the regulatory and control functions legally conferred upon the Argentine Nuclear Regulatory Authority concerning radiological risks, as well as a critical analysis of the radiological risk acceptance criteria contained in the Argentine regulatory system. A summary of the application of regulatory standards AR 3.1.3. - 'Radiological criteria related to accidents in nuclear power reactors' and AR 4.1.3. - 'Radiological criteria related to accidents in research reactors' to concrete cases is made, while the favourable and unfavourable aspects of the risk acceptance criteria are discussed. The conclusion is that the Argentine regulatory system contains adequate radiological risk acceptance criteria, that the latter are consistent with the radiological protection principles applicable to man and that, for the moment, there is no need to perform any modifications that would broaden the conceptual framework on which such criteria are based. (author) [es

  8. Multi criteria analysis in the renewable energy industry

    CERN Document Server

    San Cristóbal Mateo, José Ramón

    2012-01-01

    Decision makers in the Renewable Energy sector face an increasingly complex social, economic, technological, and environmental scenario in their decision process. Different groups of decision-makers become involved in the process, each group bringing along different criteria therefore, policy formulation for fossil fuel substitution by Renewable Energies must be addressed in a multi-criteria context. Multi Criteria Analysis in the Renewable Energy Industry is a direct response to the increasing interest in the Renewable Energy industry which can be seen as an important remedy to many environmental problems that the world faces today. The multiplicity of criteria and the increasingly complex social, economic, technological, and environmental scenario makes multi-criteria analysis a valuable tool in the decision-making process for fossil fuel substitution. The detailed chapters explore the use of the Multi-criteria decision-making methods and how they provide valuable assistance in reaching equitable and accept...

  9. Conversion to dementia in mild cognitive impairment diagnosed with DSM-5 criteria and with Petersen's criteria.

    Science.gov (United States)

    Marcos, G; Santabárbara, J; Lopez-Anton, R; De-la-Cámara, C; Gracia-García, P; Lobo, E; Pírez, G; Menchón, J M; Palomo, T; Stephan, B C M; Brayne, C; Lobo, A

    2016-05-01

    In a background of revision of criteria for states of increased risk for progression to dementia, we compare the conversion rate to dementia and Alzheimer's disease (AD) of mild cognitive impairment (MCI) as diagnosed using DSM-5 (DSM-5-MCI) and Petersen's (P-MCI) criteria. A population representative cohort of 4057 dementia-free individuals 55+ years of age was followed up at 2.5 and 4.5 years in Zaragoza, Spain (ZARADEMP). Using the Geriatric Mental State- AGECAT for assessment, research psychiatrists diagnosed DSM-5-MCI and P-MCI following operationalized criteria. 'Conversion rate' (CR), 'annual conversion rate' (ACR), and incidence rate (IR) were calculated along with incidence rate ratio (IRR) to compare the performance of the intermediate cognitive definitions. At 4.5-year follow-up, in individuals aged 65+ years, ACRs for non-cases, P-MCI, and DSM-5-MCI were 0.8, 1.9 and 3.4, respectively, for global dementia. The IRRs were 2.9 and 5.3 for P-MCI and DSM5-MCI, respectively, being the non-cases the reference category. The corresponding values were slightly lower for AD. Conversion rate to dementia and AD was higher using DSM-5-MCI criteria than using Petersen's criteria. However, prediction of the construct still has some way to go, as most MCI individuals did not convert at 4.5-year follow-up. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Hanford Site solid waste acceptance criteria

    International Nuclear Information System (INIS)

    Ellefson, M.D.

    1998-01-01

    Order 5820.2A requires that each treatment, storage, and/or disposal facility (referred to in this document as TSD unit) that manages low-level or transuranic waste (including mixed waste and TSCA PCB waste) maintain waste acceptance criteria. These criteria must address the various requirements to operate the TSD unit in compliance with applicable safety and environmental requirements. This document sets forth the baseline criteria for acceptance of radioactive waste at TSD units operated by WMH. The criteria for each TSD unit have been established to ensure that waste accepted can be managed in a manner that is within the operating requirements of the unit, including environmental regulations, DOE Orders, permits, technical safety requirements, waste analysis plans, performance assessments, and other applicable requirements. Acceptance criteria apply to the following TSD units: the Low-Level Burial Grounds (LLBG) including both the nonregulated portions of the LLBG and trenches 31 and 34 of the 218-W-5 Burial Ground for mixed waste disposal; Central Waste Complex (CWC); Waste Receiving and Processing Facility (WRAP); and T Plant Complex. Waste from all generators, both from the Hanford Site and from offsite facilities, must comply with these criteria. Exceptions can be granted as provided in Section 1.6. Specific waste streams could have additional requirements based on the 1901 identified TSD pathway. These requirements are communicated in the Waste Specification Records (WSRds). The Hanford Site manages nonradioactive waste through direct shipments to offsite contractors. The waste acceptance requirements of the offsite TSD facility must be met for these nonradioactive wastes. This document does not address the acceptance requirements of these offsite facilities

  11. Chondromalacia patellae: an in vitro study. Comparison of MR criteria with histologic and macroscopic findings

    International Nuclear Information System (INIS)

    Leersum, M. van; Schweitzer, M.E.; Gannon, F.; Finkel, G.; Vinitski, S.; Mitchell, D.G.

    1996-01-01

    Objective. To develop MR criteria for grades of chondromalacia patellae and to assess the accuracy of these grades. Design. Fat-suppressed T2-weighted double-echo, fat-suppressed T2-weighted fast spin echo, fat-suppressed T1-weighted, and gradient echo sequences were performed at 1.5 T for the evaluation of chondromalacia. A total of 1000 MR, 200 histologic, and 200 surface locations were graded for chondromalacia and statistically compared. Results. Compared with gross inspection as well as with histology the most accurate sequences were fat-suppressed T2-weighted conventional spin echo and fat suppressed T2-weighted fast spin echo, although the T1-weighted and proton density images also correlated well. The most accurate MR criteria applied to the severe grades of chondromalacia, with less accurate results for lesser grades. Conclusions. This study demonstrates that fat-suppressed routine T2-weighted and fast spin echo T2-weighted sequences seem to be more accurate than proton density, T1-weighted, and gradient echo sequences in grading chondromalacia. Good histologic and macroscopic correlation was seen in more severe grades of chondromalacia, but problems remain for the early grades in all sequences studied. (orig.). With 2 figs., 3 tabs

  12. Chondromalacia patellae: an in vitro study. Comparison of MR criteria with histologic and macroscopic findings

    Energy Technology Data Exchange (ETDEWEB)

    Leersum, M. van [Department of Radiology, Thomas Jefferson University Hospital, Philadelphia, PA (United States); Schweitzer, M.E. [Department of Radiology, Thomas Jefferson University Hospital, Philadelphia, PA (United States); Gannon, F. [Department of Pathology, Thomas Jefferson University Hospital, Philadelphia, PA (United States); Finkel, G. [Department of Pathology, Thomas Jefferson University Hospital, Philadelphia, PA (United States); Vinitski, S. [Department of Radiology, Thomas Jefferson University Hospital, Philadelphia, PA (United States); Mitchell, D.G. [Department of Radiology, Thomas Jefferson University Hospital, Philadelphia, PA (United States)

    1996-11-01

    Objective. To develop MR criteria for grades of chondromalacia patellae and to assess the accuracy of these grades. Design. Fat-suppressed T2-weighted double-echo, fat-suppressed T2-weighted fast spin echo, fat-suppressed T1-weighted, and gradient echo sequences were performed at 1.5 T for the evaluation of chondromalacia. A total of 1000 MR, 200 histologic, and 200 surface locations were graded for chondromalacia and statistically compared. Results. Compared with gross inspection as well as with histology the most accurate sequences were fat-suppressed T2-weighted conventional spin echo and fat suppressed T2-weighted fast spin echo, although the T1-weighted and proton density images also correlated well. The most accurate MR criteria applied to the severe grades of chondromalacia, with less accurate results for lesser grades. Conclusions. This study demonstrates that fat-suppressed routine T2-weighted and fast spin echo T2-weighted sequences seem to be more accurate than proton density, T1-weighted, and gradient echo sequences in grading chondromalacia. Good histologic and macroscopic correlation was seen in more severe grades of chondromalacia, but problems remain for the early grades in all sequences studied. (orig.). With 2 figs., 3 tabs.

  13. A Meta-Analysis of Typhoid Diagnostic Accuracy Studies: A Recommendation to Adopt a Standardized Composite Reference.

    Directory of Open Access Journals (Sweden)

    Helen L Storey

    Full Text Available Novel typhoid diagnostics currently under development have the potential to improve clinical care, surveillance, and the disease burden estimates that support vaccine introduction. Blood culture is most often used as the reference method to evaluate the accuracy of new typhoid tests; however, it is recognized to be an imperfect gold standard. If no single gold standard test exists, use of a composite reference standard (CRS can improve estimation of diagnostic accuracy. Numerous studies have used a CRS to evaluate new typhoid diagnostics; however, there is no consensus on an appropriate CRS. In order to evaluate existing tests for use as a reference test or inclusion in a CRS, we performed a systematic review of the typhoid literature to include all index/reference test combinations observed. We described the landscape of comparisons performed, showed results of a meta-analysis on the accuracy of the more common combinations, and evaluated sources of variability based on study quality. This wide-ranging meta-analysis suggests that no single test has sufficiently good performance but some existing diagnostics may be useful as part of a CRS. Additionally, based on findings from the meta-analysis and a constructed numerical example demonstrating the use of CRS, we proposed necessary criteria and potential components of a typhoid CRS to guide future recommendations. Agreement and adoption by all investigators of a standardized CRS is requisite, and would improve comparison of new diagnostics across independent studies, leading to the identification of a better reference test and improved confidence in prevalence estimates.

  14. Systematic review of proposed definitions of nocturnal polyuria and population-based evidence of their diagnostic accuracy.

    Science.gov (United States)

    Olesen, Tine Kold; Denys, Marie-Astrid; Vande Walle, Johan; Everaert, Karel

    2018-02-06

    Background Evidence of diagnostic accuracy for proposed definitions of nocturnal polyuria is currently unclear. Purpose Systematic review to determine population-based evidence of the diagnostic accuracy of proposed definitions of nocturnal polyuria based on data from frequency-volume charts. Methods Seventeen pre-specified search terms identified 351 unique investigations published from 1990 to 2016 in BIOSIS, Embase, Embase Alerts, International Pharmaceutical Abstract, Medline, and Cochrane. Thirteen original communications were included in this review based on pre-specified exclusion criteria. Data were extracted from each paper regarding subject age, sex, ethnicity, health status, sample size, data collection methods, and diagnostic discrimination of proposed definitions including sensitivity, specificity, positive and negative predictive value. Results The sample size of study cohorts, participant age, sex, ethnicity, and health status varied considerably in 13 studies reporting on the diagnostic performance of seven different definitions of nocturnal polyuria using frequency-volume chart data from 4968 participants. Most study cohorts were small, mono-ethnic, including only Caucasian males aged 50 or higher with primary or secondary polyuria that were compared to a control group of healthy men without nocturia in prospective or retrospective settings. Proposed definitions had poor discriminatory accuracy in evaluations based on data from subjects independent from the original study cohorts with findings being similar regarding the most widely evaluated definition endorsed by ICS. Conclusions Diagnostic performance characteristics for proposed definitions of nocturnal polyuria show poor to modest discrimination and are not based on sufficient level of evidence from representative, multi-ethnic population-based data from both females and males of all adult ages.

  15. Examining those Meeting IOM Criteria Versus IOM Plus Fibromyalgia

    OpenAIRE

    Jason, Leonard A; McManimen, Stephanie; Sunnquist, Madison; Newton, Julia L; Strand, Elin Bolle

    2017-01-01

    The Institute of Medicine (IOM) recently developed clinical criteria for chronic fatigue syndrome (CFS). There might be additional criteria that could select a more homogenous and impaired group of patients, particularly those with pain. The current study focused on criteria which involved meeting the four IOM criteria, excluding medical and psychiatric co-morbidities, along with having fibromyalgia (FM). Findings indicated that those meeting the IOM clinical criteria plus FM were more impair...

  16. Development of threshold action criteria for light water reactors

    International Nuclear Information System (INIS)

    Okrent, D.; Baldewicz, W.L.

    1982-06-01

    A survey of recently threshold criteria for regulatory action on LWRs is presented together with some commentary. This is followed by a new proposal for threshold action criteria which includes some different risk attributes than are found in previous criteria. Some preliminary risk values are suggested for the criteria and then evaluated in terms of a few hypothetical accident scenarios. Finally, several licensing issues are examined in terms of various threshold action criteria

  17. Accuracy of Daily Lung Ultrasound for the Detection of Pulmonary Edema Following Subarachnoid Hemorrhage.

    Science.gov (United States)

    Williamson, Craig A; Co, Ivan; Pandey, Aditya S; Gregory Thompson, B; Rajajee, Venkatakrishna

    2016-04-01

    Early detection of pulmonary edema is vital to appropriate fluid management following subarachnoid hemorrhage (SAH). Lung ultrasound (LUS) has been shown to accurately identify pulmonary edema in patients with acute respiratory failure (ARF). Our objective was to determine the accuracy of daily screening LUS for the detection of pulmonary edema following SAH. Screening LUS was performed in conjunction with daily transcranial doppler for SAH patients within the delayed cerebral ischemia (DCI) risk period in our neuroICU. We reviewed records of SAH patients admitted 7/2012-5/2014 who underwent bilateral LUS on at least 5 consecutive days. Ultrasound videos were reviewed by an investigator blinded to the final diagnosis. "B+ lines" were defined as ≥3 B-lines on LUS. Two other investigators blinded to ultrasound results determined whether pulmonary edema with ARF (PE-ARF) was present during the period of evaluation on the basis of independent chart review, with a fourth investigator performing adjudication in the event of disagreement. The diagnostic accuracy of B+ lines for the detection of PE-ARF and RPE was determined. Of 59 patients meeting criteria for inclusion, 21 (36%) had PE-ARF and 26 (44%) had B+ lines. Kappa for inter-rater agreement was 0.821 (p pulmonary edema following SAH and may assist with fluid titration during the risk period for DCI.

  18. Factors Related to the Accuracy of Self-Reported Dietary Intake of Children Aged 6 to 12 Years Elicited with Interviews: A Systematic Review.

    Science.gov (United States)

    Sharman, Stefanie J; Skouteris, Helen; Powell, Martine B; Watson, Brittany

    2016-01-01

    Understanding the relationship between children's dietary consumption and health is important. As such, it is crucial to explore factors related to the accuracy of children's reports of what they consumed. The objective was to evaluate factors related to the accuracy of self-reported dietary intake information elicited by interview methods from children aged 6 to 12 years. A systematic review of English articles using PsycINFO, PsycARTICLES, PsycEXTRA, PsycBOOKS, CINAHL Complete, Global Health, and MEDLINE Complete was performed. Search terms included interview, diet, children, and recall; studies were limited to those published from 1970 onward. Additional studies were identified using the reference lists of published articles. Studies that assessed children's dietary intake using direct observation, doubly labeled water, or the double-portion method and compared it with their recall of that intake (unassisted by parents) using an interview were included. The 45 studies that met the inclusion criteria showed that specific interview techniques designed to enhance children's recall accuracy had little effect. Rather, the timing of the interview appeared most important: The shorter the retention interval between children's consumption and their recall, the more accurate their memories. Children's age, body mass index, social desirability, food preferences, and cognitive ability were also related to accuracy. Factors related to the accuracy of children's dietary reporting should be taken into consideration when asking about consumption. Further research is required to examine whether other interview techniques, such as those developed to enhance children's recall of repeated staged events, can improve children's dietary reporting accuracy. Copyright © 2016 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  19. Accuracies Of Optical Processors For Adaptive Optics

    Science.gov (United States)

    Downie, John D.; Goodman, Joseph W.

    1992-01-01

    Paper presents analysis of accuracies and requirements concerning accuracies of optical linear-algebra processors (OLAP's) in adaptive-optics imaging systems. Much faster than digital electronic processor and eliminate some residual distortion. Question whether errors introduced by analog processing of OLAP overcome advantage of greater speed. Paper addresses issue by presenting estimate of accuracy required in general OLAP that yields smaller average residual aberration of wave front than digital electronic processor computing at given speed.

  20. Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions – Changes in Accuracy over Time

    Science.gov (United States)

    Lebel, Karina; Boissy, Patrick; Hamel, Mathieu; Duval, Christian

    2015-01-01

    Background Interest in 3D inertial motion tracking devices (AHRS) has been growing rapidly among the biomechanical community. Although the convenience of such tracking devices seems to open a whole new world of possibilities for evaluation in clinical biomechanics, its limitations haven’t been extensively documented. The objectives of this study are: 1) to assess the change in absolute and relative accuracy of multiple units of 3 commercially available AHRS over time; and 2) to identify different sources of errors affecting AHRS accuracy and to document how they may affect the measurements over time. Methods This study used an instrumented Gimbal table on which AHRS modules were carefully attached and put through a series of velocity-controlled sustained motions including 2 minutes motion trials (2MT) and 12 minutes multiple dynamic phases motion trials (12MDP). Absolute accuracy was assessed by comparison of the AHRS orientation measurements to those of an optical gold standard. Relative accuracy was evaluated using the variation in relative orientation between modules during the trials. Findings Both absolute and relative accuracy decreased over time during 2MT. 12MDP trials showed a significant decrease in accuracy over multiple phases, but accuracy could be enhanced significantly by resetting the reference point and/or compensating for initial Inertial frame estimation reference for each phase. Interpretation The variation in AHRS accuracy observed between the different systems and with time can be attributed in part to the dynamic estimation error, but also and foremost, to the ability of AHRS units to locate the same Inertial frame. Conclusions Mean accuracies obtained under the Gimbal table sustained conditions of motion suggest that AHRS are promising tools for clinical mobility assessment under constrained conditions of use. However, improvement in magnetic compensation and alignment between AHRS modules are desirable in order for AHRS to reach their

  1. The diagnostic accuracy of serological tests for Lyme borreliosis in Europe: a systematic review and meta-analysis.

    Science.gov (United States)

    Leeflang, M M G; Ang, C W; Berkhout, J; Bijlmer, H A; Van Bortel, W; Brandenburg, A H; Van Burgel, N D; Van Dam, A P; Dessau, R B; Fingerle, V; Hovius, J W R; Jaulhac, B; Meijer, B; Van Pelt, W; Schellekens, J F P; Spijker, R; Stelma, F F; Stanek, G; Verduyn-Lunel, F; Zeller, H; Sprong, H

    2016-03-25

    Interpretation of serological assays in Lyme borreliosis requires an understanding of the clinical indications and the limitations of the currently available tests. We therefore systematically reviewed the accuracy of serological tests for the diagnosis of Lyme borreliosis in Europe. We searched EMBASE en MEDLINE and contacted experts. Studies evaluating the diagnostic accuracy of serological assays for Lyme borreliosis in Europe were eligible. Study selection and data-extraction were done by two authors independently. We assessed study quality using the QUADAS-2 checklist. We used a hierarchical summary ROC meta-regression method for the meta-analyses. Potential sources of heterogeneity were test-type, commercial or in-house, Ig-type, antigen type and study quality. These were added as covariates to the model, to assess their effect on test accuracy. Seventy-eight studies evaluating an Enzyme-Linked ImmunoSorbent assay (ELISA) or an immunoblot assay against a reference standard of clinical criteria were included. None of the studies had low risk of bias for all QUADAS-2 domains. Sensitivity was highly heterogeneous, with summary estimates: erythema migrans 50% (95% CI 40% to 61%); neuroborreliosis 77% (95% CI 67% to 85%); acrodermatitis chronica atrophicans 97% (95% CI 94% to 99%); unspecified Lyme borreliosis 73% (95% CI 53% to 87%). Specificity was around 95% in studies with healthy controls, but around 80% in cross-sectional studies. Two-tiered algorithms or antibody indices did not outperform single test approaches. The observed heterogeneity and risk of bias complicate the extrapolation of our results to clinical practice. The usefulness of the serological tests for Lyme disease depends on the pre-test probability and subsequent predictive values in the setting where the tests are being used. Future diagnostic accuracy studies should be prospectively planned cross-sectional studies, done in settings where the test will be used in practice.

  2. Diagnostic accuracy of tests to detect hepatitis B surface antigen: a systematic review of the literature and meta-analysis

    Directory of Open Access Journals (Sweden)

    Ali Amini

    2017-11-01

    Full Text Available Abstract Background Chronic Hepatitis B Virus (HBV infection is characterised by the persistence of hepatitis B surface antigen (HBsAg. Expanding HBV diagnosis and treatment programmes into low resource settings will require high quality but inexpensive rapid diagnostic tests (RDTs in addition to laboratory-based enzyme immunoassays (EIAs to detect HBsAg. The purpose of this review is to assess the clinical accuracy of available diagnostic tests to detect HBsAg to inform recommendations on testing strategies in 2017 WHO hepatitis testing guidelines. Methods The systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA guidelines using 9 databases. Two reviewers independently extracted data according to a pre-specified plan and evaluated study quality. Meta-analysis was performed. HBsAg diagnostic accuracy of rapid diagnostic tests (RDTs was compared to enzyme immunoassay (EIA and nucleic-acid test (NAT reference standards. Subanalyses were performed to determine accuracy among brands, HIV-status and specimen type. Results Of the 40 studies that met the inclusion criteria, 33 compared RDTs and/or EIAs against EIAs and 7 against NATs as reference standards. Thirty studies assessed diagnostic accuracy of 33 brands of RDTs in 23,716 individuals from 23 countries using EIA as the reference standard. The pooled sensitivity and specificity were 90.0% (95% CI: 89.1, 90.8 and 99.5% (95% CI: 99.4, 99.5 respectively, but accuracy varied widely among brands. Accuracy did not differ significantly whether serum, plasma, venous or capillary whole blood was used. Pooled sensitivity of RDTs in 5 studies of HIV-positive persons was lower at 72.3% (95% CI: 67.9, 76.4 compared to that in HIV-negative persons, but specificity remained high. Five studies evaluated 8 EIAs against a chemiluminescence immunoassay reference standard with a pooled sensitivity and specificity of 88.9% (95% CI: 87.0, 90.6 and

  3. 40 CFR 227.31 - Applicable marine water quality criteria.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Applicable marine water quality... § 227.31 Applicable marine water quality criteria. Applicable marine water quality criteria means the criteria given for marine waters in the EPA publication “Quality Criteria for Water” as published in 1976...

  4. Criteria for authorship in bioethics.

    Science.gov (United States)

    Resnik, David B; Master, Zubin

    2011-10-01

    Multiple authorship is becoming increasingly common in bioethics research. There are well-established criteria for authorship in empirical bioethics research but not for conceptual research. It is important to develop criteria for authorship in conceptual publications to prevent undeserved authorship and uphold standards of fairness and accountability. This article explores the issue of multiple authorship in bioethics and develops criteria for determining who should be an author on a conceptual publication in bioethics. Authorship in conceptual research should be based on contributing substantially to: (1) identifying a topic, problem, or issue to study; (2) reviewing and interpreting the relevant literature; (3) formulating, analyzing, and evaluating arguments that support one or more theses; (4) responding to objections and counterarguments; and (5) drafting the manuscript. Authors of conceptual publications should participate substantially in at least two of areas (1)-(5) and also approve the final version. [corrected].

  5. Validation of the 2010 ACR/EULAR classification criteria for rheumatoid arthritis: slight improvement over the 1987 ACR criteria.

    NARCIS (Netherlands)

    Britsemmer, K.; Ursum, J.; Gerritsen, M.; Tuyl, L. van; Schaardenburg, D. van

    2011-01-01

    Abstract: Background Recently, an American College of Rheumatology (ACR)/European League Against Rheumatism (EULAR) collaboration developed new classification criteria for rheumatoid arthritis (RA). Objective:To evaluate the diagnostic and discriminative ability of these new criteria compared with

  6. Evaluation Criteria for the Educational Web-Information System

    Science.gov (United States)

    Seok, Soonhwa; Meyen, Edward; Poggio, John C.; Semon, Sarah; Tillberg-Webb, Heather

    2008-01-01

    This article addresses how evaluation criteria improve educational Web-information system design, and the tangible and intangible benefits of using evaluation criteria, when implemented in an educational Web-information system design. The evaluation criteria were developed by the authors through a content validation study applicable to…

  7. 7 CFR 1948.80 - Planning grant selection criteria.

    Science.gov (United States)

    2010-01-01

    ... financial resources available for such planning; (d) The planning priorities and recommended funding level... 7 Agriculture 13 2010-01-01 2009-01-01 true Planning grant selection criteria. 1948.80 Section... Development Assistance Program § 1948.80 Planning grant selection criteria. The following criteria will be...

  8. Research on probabilistic assessment method based on the corroded pipeline assessment criteria

    International Nuclear Information System (INIS)

    Zhang Guangli; Luo, Jinheng; Zhao Xinwei; Zhang Hua; Zhang Liang; Zhang Yi

    2012-01-01

    Pipeline integrity assessments are performed using conventional deterministic approaches, even though there are many uncertainties about the parameters in the pipeline integrity assessment. In this paper, a probabilistic assessment method is provided for the gas pipeline with corrosion defects based on the current corroded pipe evaluation criteria, and the failure probability of corroded pipelines due to the uncertainties of loadings, material property and measurement accuracy is estimated using Monte-Carlo technique. Furthermore, the sensitivity analysis approach is introduced to rank the influence of various random variables to the safety of pipeline. And the method to determine the critical defect size based on acceptable failure probability is proposed. Highlights: ► The folias factor in pipeline corrosion assessment methods was analyzed. ► The probabilistic method was applied in corrosion assessment methods. ► The influence of assessment variables to the reliability of pipeline was ranked. ► The acceptable failure probability was used to determine the critical defect size.

  9. Top-level regulatory criteria for the standard MHTGR

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1986-10-15

    The Licensing Plan for the Standard MHTGR (Ref. 1) describes a program to support a U.S. Nuclear Regulatory Commission (NRC) design review and approval. The Plan calls for the submittal of Top-Level Regulatory Criteria to the NRC for concurrence with their completeness and acceptability for the MHTGR program. The Top-Level Regulatory Criteria are defined as the standards for judging licensability that directly specify acceptable limits for protection of the public health and safety and the environment. The criteria proposed herein are for normal plant operation and a broad spectrum of anticipated events, including accidents. The approach taken is to define a set of criteria which are general as opposed to being design specific. Specifically, it is recommended that criteria be met which: 1. Are less prescriptive than current regulation, thereby encouraging maximum flexibility in design approaches. 2. Are measurable. 3. Are not more strict than the criteria for current power plants.

  10. DEMO diagnostics and burn control

    NARCIS (Netherlands)

    Biel, W.; De Baar, M.; Dinklage, A.; Felici, F.; König, R.; Meister, H.; Treutterer, W.; Wenninger, R.

    2015-01-01

    The development of the control system for a tokamak demonstration fusion reactor (DEMO) faces unprecedented challenges. First, the requirements for control reliability and accuracy are more stringent than on existing fusion devices: any loss of plasma control on DEMO may result in a disruption which

  11. RF Performance of a 600-720 GHz Sideband Separating Mixer with All-Copper Micromachined Waveguide Mixer Block

    NARCIS (Netherlands)

    Mena, F. P.; Kooi, J.; Baryshev, A. M.; Lodewijk, C. F. J.; Klapwijk, T. M.; Wild, W.; Desmaris, V.; Meledin, D.; Pavolotsky, A.; Belitsky, V.; Wild, Wolfgang

    2008-01-01

    Here we report on the RF performance of a 2SB mixer (600-720 GHz) fabricated in a new method that combines traditional micromachining with waveguide components fabricated by photolithography and electroplating. The latter allows reaching, in a reproducible way, the stringent accuracies necessary for

  12. Accuracy of the contemporary Epstein criteria to predict insignificant ...

    African Journals Online (AJOL)

    A. Ammani

    2016-07-26

    Jul 26, 2016 ... The radical prostatectomy specimens were analyzed in order to identify the rate ... prostate-specific antigen (PSA) and digital rectal examination. (DRE) in combination .... of all the tumor foci, excluding benign prostate tissue.

  13. 16 CFR 1031.15 - Communication criteria.

    Science.gov (United States)

    2010-01-01

    ... nature and a report of each oral communication of a substantive nature between a Commission official or... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Communication criteria. 1031.15 Section 1031... Communication criteria. (a) Commission officials and employees, who are not in the positions listed in § 1031.12...

  14. Validation criteria of an internal dosimetry laboratory in vivo; Criterios para la validacion de un laboratorio de dosimetria interna in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Alfaro L, M. de las M., E-mail: mercedes.alfaro@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2014-10-15

    People working with radioactive materials, under certain circumstances (e.g. not using the proper protective equipment, an incident not covered, etc.) could be incorporated into the body. The radiation protection programs include direct measurement methods -in vivo- or indirect -in vitro- or both, to know that radioactive material is incorporated into the body. The monitoring measurements of internal contamination or (Radio-bioassay) are carried out with the purpose of determining the amount of radioactive material incorporated in the body; estimate the effective dose and committed dose; management administration of radiation protection; appropriate medical management; and to provide the data necessary for the legal requirements and the preservation of records. The measurement methods used in the monitoring of internal contamination must be validated by the combination of the following processes: calibration, using standards reference materials and/or simulators; execute systematic research, using control samples; and intercomparison between laboratories and performance tests. In this paper the validation criteria of an internal dosimetry laboratory in vivo are presented following the information provided by the standard ANSI N13-30-1996 and ISO/TEC 17025-2005 as are the criteria of facilities, staff training, interpretation of measurements, performance criteria for monitoring of internal contamination in vivo, results reporting and records retention. Thereby we achieve standardized quantitative performance criteria of truthfulness, accuracy and detection limit and a consensus on statistical definitions to establish the validation plan of a monitoring laboratory of internal contamination in vivo. (Author)

  15. Rett syndrome diagnostic criteria: lessons from the Natural History Study.

    Science.gov (United States)

    Percy, Alan K; Neul, Jeffrey L; Glaze, Daniel G; Motil, Kathleen J; Skinner, Steven A; Khwaja, Omar; Lee, Hye-Seung; Lane, Jane B; Barrish, Judy O; Annese, Fran; McNair, Lauren; Graham, Joy; Barnes, Katherine

    2010-12-01

    Analysis of 819 participants enrolled in the Rett syndrome (RTT) Natural History Study validates recently revised diagnostic criteria. 765 females fulfilled 2002 consensus criteria for classic (653/85.4%) or variant (112/14.6%) RTT. All participants classified as classic RTT fulfilled each revised main criterion; supportive criteria were not uniformly present. All variant RTT participants met at least 3 of 6 main criteria in the 2002, 2 of 4 main criteria in the current format, and 5 of 11 supportive criteria in both. This analysis underscores the critical role of main criteria for classic RTT; variant RTT requires both main and supportive criteria.

  16. Comparison of diagnostic classification systems for delirium with new research criteria that incorporate the three core domains.

    Science.gov (United States)

    Trzepacz, Paula T; Meagher, David J; Franco, José G

    2016-05-01

    Diagnostic classification systems do not incorporate phenomenological research findings about the three core symptom domains of delirium (Attentional/Cognitive, Circadian, Higher Level Thinking). We evaluated classification performances of novel Trzepacz, Meagher, and Franco research diagnostic criteria (TMF) that incorporate those domains and ICD-10, DSM-III-R, DSM-IV, and DSM-5. Primary data analysis of 641 patients with mixed neuropsychiatric profiles. Delirium (n=429) and nondelirium (n=212) reference standard groups were identified using cluster analysis of symptoms assessed using the Delirium Rating Scale-Revised-98. Accuracy, sensitivity, specificity, positive and negative predictive values (PPV, NPV), and likelihood ratios (LR+, LR-) are reported. TMF criteria had high sensitivity and specificity (87.4% and 89.2%), more balanced than DSM-III-R (100% and 31.6%), DSM-IV (97.7% and 74.1%), DSM-5 (97.7% and 72.6%), and ICD-10 (66.2% and 100%). PPV of DSM-III-R, DSM-IV, and DSM-5 were 90%. ICD-10 had the lowest NPV (59.4%). TMF had the highest LR+ (8.06) and DSM-III-R the lowest LR- (0.0). Overall, values for DSM-IV and DSM-5 were similar, whereas for ICD-10 and DSM-III-R were inverse of each other. In the pre-existing cognitive impairment/dementia subsample (n=128), TMF retained its highest LR+ though specificity (58.3%) became less well balanced with sensitivity (87.9%), which still exceeded that of DSM. TMF research diagnostic criteria performed well, with more balanced sensitivity and specificity and the highest likelihood ratio for delirium identification. Reflecting the three core domains of delirium, TMF criteria may have advantages in biological research where delineation of this syndrome is important. Copyright © 2016. Published by Elsevier Inc.

  17. 47 CFR 68.608 - Publication of technical criteria.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Publication of technical criteria. 68.608... Attachments § 68.608 Publication of technical criteria. The Administrative Council for Terminal Attachments shall place technical criteria proposed for publication on public notice for 30 days. At the end of the...

  18. Geriatric-specific triage criteria are more sensitive than standard adult criteria in identifying need for trauma center care in injured older adults.

    Science.gov (United States)

    Ichwan, Brian; Darbha, Subrahmanyam; Shah, Manish N; Thompson, Laura; Evans, David C; Boulger, Creagh T; Caterino, Jeffrey M

    2015-01-01

    We evaluate the sensitivity of Ohio's 2009 emergency medical services (EMS) geriatric trauma triage criteria compared with the previous adult triage criteria in identifying need for trauma center care among older adults. We studied a retrospective cohort of injured patients aged 16 years or older in the 2006 to 2011 Ohio Trauma Registry. Patients aged 70 years or older were considered geriatric. We identified whether each patient met the geriatric and the adult triage criteria. The outcome measure was need for trauma center care, defined by surrogate markers: Injury Severity Score greater than 15, operating room in fewer than 48 hours, any ICU stay, and inhospital mortality. We calculated sensitivity and specificity of both triage criteria for both age groups. We included 101,577 patients; 33,379 (33%) were geriatric. Overall, 57% of patients met adult criteria and 68% met geriatric criteria. Using Injury Severity Score, for older adults geriatric criteria were more sensitive for need for trauma center care (93%; 95% confidence interval [CI] 92% to 93%) than adult criteria (61%; 95% CI 60% to 62%). Geriatric criteria decreased specificity in older adults from 61% (95% CI 61% to 62%) to 49% (95% CI 48% to 49%). Geriatric criteria in older adults (93% sensitivity, 49% specificity) performed similarly to the adult criteria in younger adults (sensitivity 87% and specificity 44%). Similar patterns were observed for other outcomes. Standard adult EMS triage guidelines provide poor sensitivity in older adults. Ohio's geriatric trauma triage guidelines significantly improve sensitivity in identifying Injury Severity Score and other surrogate markers of the need for trauma center care, with modest decreases in specificity for older adults. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  19. Rationales for the Lightning Launch Commit Criteria

    Science.gov (United States)

    Willett, John C. (Editor); Merceret, Francis J. (Editor); Krider, E. Philip; O'Brien, T. Paul; Dye, James E.; Walterscheid, Richard L.; Stolzenburg, Maribeth; Cummins, Kenneth; Christian, Hugh J.; Madura, John T.

    2016-01-01

    Since natural and triggered lightning are demonstrated hazards to launch vehicles, payloads, and spacecraft, NASA and the Department of Defense (DoD) follow the Lightning Launch Commit Criteria (LLCC) for launches from Federal Ranges. The LLCC were developed to prevent future instances of a rocket intercepting natural lightning or triggering a lightning flash during launch from a Federal Range. NASA and DoD utilize the Lightning Advisory Panel (LAP) to establish and develop robust rationale from which the criteria originate. The rationale document also contains appendices that provide additional scientific background, including detailed descriptions of the theory and observations behind the rationales. The LLCC in whole or part are used across the globe due to the rigor of the documented criteria and associated rationale. The Federal Aviation Administration (FAA) adopted the LLCC in 2006 for commercial space transportation and the criteria were codified in the FAA's Code of Federal Regulations (CFR) for Safety of an Expendable Launch Vehicle (Appendix G to 14 CFR Part 417, (G417)) and renamed Lightning Flight Commit Criteria in G417.

  20. Biological Water Quality Criteria

    Science.gov (United States)

    Page contains links to Technical Documents pertaining to Biological Water Quality Criteria, including, technical assistance documents for states, tribes and territories, program overviews, and case studies.

  1. Diagnostic accuracy of virtual non-contrast enhanced dual-energy CT for diagnosis of adrenal adenoma: A systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Connolly, Michael J.; McInnes, Matthew D.F.; Schieda, Nicola [University of Ottawa Department of Radiology, Clinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, ON (United States); El-Khodary, Mohamed [McMaster University Department of Radiology, Hamilton, ON (Canada); McGrath, Trevor A. [University of Ottawa, Faculty of Medicine, Ottawa, Ontario (Canada)

    2017-10-15

    To compare the diagnostic accuracy of dual-energy (DE) virtual non-contrast computed tomography (vNCT) to non-contrast CT (NCT) for the diagnosis of adrenal adenomas. Search of multiple databases and grey literature was performed. Two reviewers independently applied inclusion criteria and extracted data. Risk of bias was assessed using QUADAS-2. Summary estimates of diagnostic accuracy were generated and sources of heterogeneity were assessed. Five studies (170 patients; 192 adrenal masses) were included for diagnostic accuracy assessment; all used dual-source dual-energy CT. Pooled sensitivity for adrenal adenoma on vNCT was 54% (95% CI: 47-62%). Pooled sensitivity for NCT was 57% (95% CI: 45-69%). Pooling of specificity was not performed since no false positives were reported. There was a trend for overestimation of HU density on vNCT as compared to NCT which appeared related to contrast timing. Potential sources of bias were seen regarding the index test and reference standard for the included studies. Potential sources of heterogeneity between studies were seen in adenoma prevalence and intravenous contrast timing. vNCT images generated from dual-energy CT demonstrated comparable sensitivity to NCT for the diagnosis of adenomas; however the included studies are heterogeneous and at high risk for some types of bias. (orig.)

  2. To Predict the Requirement of Pharmacotherapy by OGTT Glucose Levels in Women with GDM Classified by the IADPSG Criteria

    Directory of Open Access Journals (Sweden)

    Gülen Yerlikaya

    2018-01-01

    Full Text Available The aim of this study was to assess the association between OGTT glucose levels and requirement of pharmacotherapy in GDM patients classified by the IADPSG criteria. This study included 203 GDM patients (108 managed with lifestyle modification and 95 requiring pharmacotherapy. Clinical risk factors and OGTT glucose concentrations at 0 (G0, 60 (G60, and 120 min (G120 were collected. OGTT glucose levels were significantly associated with the later requirement of pharmacotherapy (ROC-AUC: 71.1, 95% CI: 63.8–78.3. Also, the combination of clinical risk factors (age, BMI, parity, and pharmacotherapy in previous gestation showed an acceptable predictive accuracy (ROC-AUC: 72.1, 95% CI: 65.0–79.2, which was further improved when glycemic parameters were added (ROC-AUC: 77.5, 95% CI: 71.5–83.9. Random forest analysis revealed the highest variable importance for G0, G60, and age. OGTT glucose measures in addition to clinical risk factors showed promising properties for risk stratification in GDM patients classified by the recently established IADPSG criteria.

  3. Cleanup criteria for the West Valley demonstration project

    International Nuclear Information System (INIS)

    Parrott, J.D.

    1999-01-01

    The US Nuclear Regulatory Commission (NRC) is prescribing decontamination and decommissioning (cleanup) criteria for the West Valley Demonstration Project and the West Valley, New York, site. The site is contaminated with various forms of residual radioactive contamination and contains a wide variety of radioactive waste. The NRC is planning to issue cleanup criteria for public comment in Fall 1999. Due to the complexity of the site, and the newness of NRC's cleanup criteria policy, applying NRC's cleanup criteria to this site will be an original regulatory undertaking. (author)

  4. Surgical accuracy of three-dimensional virtual planning

    DEFF Research Database (Denmark)

    Stokbro, Kasper; Aagaard, Esben; Torkov, Peter

    2016-01-01

    This retrospective study evaluated the precision and positional accuracy of different orthognathic procedures following virtual surgical planning in 30 patients. To date, no studies of three-dimensional virtual surgical planning have evaluated the influence of segmentation on positional accuracy...... and transverse expansion. Furthermore, only a few have evaluated the precision and accuracy of genioplasty in placement of the chin segment. The virtual surgical plan was compared with the postsurgical outcome by using three linear and three rotational measurements. The influence of maxillary segmentation...

  5. Repository operational criteria comparative analysis

    International Nuclear Information System (INIS)

    Hageman, J.P.; Chowdhury, A.H.

    1994-06-01

    The objective of the ''Repository Operational Criteria (ROC) Feasibility Studies'' (or ROC task) was to conduct comprehensive and integrated analyses of repository design, construction, and operations criteria in 10 CFR Part 60 regulations considering the interfaces among the components of the regulations and impacts of any potential changes to those regulations. The ROC task addresses regulatory criteria and uncertainties related to the preclosure aspects of the geologic repository. Those parts of 10 CFR Part 60 that require routine guidance or minor changes to the rule were addressed in Hageman and Chowdhury, 1992. The ROC task shows a possible need for further regulatory clarity, by major changes to the rule, related to the design bases and siting of a geologic repository operations area and radiological emergency planning in order to assure defense-in-depth. The analyses, presented in this report, resulted in the development and refinement of regulatory concepts and their supporting rationale for recommendations for potential major changes to 10 CFR Pan 0 regulations

  6. FFTF criteria for run to cladding breach experiments

    International Nuclear Information System (INIS)

    Van Keuren, J.C.; Heard, F.J.; Stepnewski, D.D.

    1985-12-01

    The review of experiments proposed for irradiation in FFTF resulted in the development of new criteria for run-to-cladding breach experiments. These criteria have allowed irradiation of aggressive experiments without compromising the safety bases for FFTF. This paper consisting of a set of narrated slides, discusses these criteria and related bases

  7. CT diagnostic criteria of branchial cysts

    Energy Technology Data Exchange (ETDEWEB)

    Jend, H.H.; Jend-Rossmann, I.; Techentin, E.C.

    1984-09-01

    Although well known, the morphology of branchial cysts has not been sufficiently presented in CT literature. In the present case report, diagnostic criteria are given, such as typical site of occurrence, ductal extension towards the supratonsillar fossa, and cystic, but occasionally soft tissue density. Differential diagnosis is given for cases which cannot be classified according to these criteria.

  8. A Meta-Analysis of the Relations among Training Criteria

    National Research Council Canada - National Science Library

    Alliger, George

    1998-01-01

    .... Meta-analysis results among criteria using this framework include the finding of substantial reliabilities across training criteria and reasonable convergence among subdivisions of criteria within a larger level...

  9. FIELD ACCURACY TEST OF RPAS PHOTOGRAMMETRY

    Directory of Open Access Journals (Sweden)

    P. Barry

    2013-08-01

    Full Text Available Baseline Surveys Ltd is a company which specialises in the supply of accurate geospatial data, such as cadastral, topographic and engineering survey data to commercial and government bodies. Baseline Surveys Ltd invested in aerial drone photogrammetric technology and had a requirement to establish the spatial accuracy of the geographic data derived from our unmanned aerial vehicle (UAV photogrammetry before marketing our new aerial mapping service. Having supplied the construction industry with survey data for over 20 years, we felt that is was crucial for our clients to clearly understand the accuracy of our photogrammetry so they can safely make informed spatial decisions, within the known accuracy limitations of our data. This information would also inform us on how and where UAV photogrammetry can be utilised. What we wanted to find out was the actual accuracy that can be reliably achieved using a UAV to collect data under field conditions throughout a 2 Ha site. We flew a UAV over the test area in a "lawnmower track" pattern with an 80% front and 80% side overlap; we placed 45 ground markers as check points and surveyed them in using network Real Time Kinematic Global Positioning System (RTK GPS. We specifically designed the ground markers to meet our accuracy needs. We established 10 separate ground markers as control points and inputted these into our photo modelling software, Agisoft PhotoScan. The remaining GPS coordinated check point data were added later in ArcMap to the completed orthomosaic and digital elevation model so we could accurately compare the UAV photogrammetry XYZ data with the RTK GPS XYZ data at highly reliable common points. The accuracy we achieved throughout the 45 check points was 95% reliably within 41 mm horizontally and 68 mm vertically and with an 11.7 mm ground sample distance taken from a flight altitude above ground level of 90 m.The area covered by one image was 70.2 m × 46.4 m, which equals 0.325 Ha. This

  10. NWTS program criteria for mined geologic disposal of nuclear waste: program objectives, functional requirements, and system performance criteria

    International Nuclear Information System (INIS)

    1981-04-01

    At the present time, final repository criteria have not been issued by the responsible agencies. This document describes general objectives, requirements, and criteria that the DOE intends to apply in the interim to the National Waste Terminal Storage (NWTS) Program. These objectives, requirements, and criteria have been developed on the basis of DOE's analysis of what is needed to achieve the National objective of safe waste disposal in an environmentally acceptable and economic manner and are expected to be consistent with anticipated regulatory standards. The qualitative statements in this document address the broad issues of public and occupational health and safety, institutional acceptability, engineering feasibility, and economic considerations. A comprehensive set of criteria, general and project specific, of which these are a part, will constitute a portion of the technical basis for preparation and submittal by the DOE of formal documents to support future license applications for nuclear waste repositories

  11. NWTS program criteria for mined geologic disposal of nuclear waste: program objectives, functional requirements, and system performance criteria

    Energy Technology Data Exchange (ETDEWEB)

    None

    1981-04-01

    At the present time, final repository criteria have not been issued by the responsible agencies. This document describes general objectives, requirements, and criteria that the DOE intends to apply in the interim to the National Waste Terminal Storage (NWTS) Program. These objectives, requirements, and criteria have been developed on the basis of DOE's analysis of what is needed to achieve the National objective of safe waste disposal in an environmentally acceptable and economic manner and are expected to be consistent with anticipated regulatory standards. The qualitative statements in this document address the broad issues of public and occupational health and safety, institutional acceptability, engineering feasibility, and economic considerations. A comprehensive set of criteria, general and project specific, of which these are a part, will constitute a portion of the technical basis for preparation and submittal by the DOE of formal documents to support future license applications for nuclear waste repositories.

  12. Diagnostic accuracy of exercise thallium-201 single-photon emission computed tomography in patients with left bundle branch block

    International Nuclear Information System (INIS)

    Larcos, G.; Gibbons, R.J.; Brown, M.L.

    1991-01-01

    Recent reports have proposed that abnormal apical or anterior wall perfusion with exercise thallium-201 imaging may increase diagnostic accuracy for disease of the left anterior descending artery in patients with left bundle branch block (LBBB). To evaluate these suggestions, 83 patients with LBBB who underwent thallium-201 single-photon emission computed tomography and coronary angiography within an interval of 3 months were retrospectively reviewed. There were 59 men and 24 women aged 33 to 84 years (mean 65). Myocardial perfusion to the apex, anterior wall and anterior septum were scored qualitatively by consensus of 2 experienced observers and by quantitative analysis in comparison with a normal data base. The sensitivity, specificity and accuracy of perfusion defects in these segments were then expressed according to angiographic findings. Significant stenosis of vessels within the left anterior descending artery territory was present in 38 patients. By receiver-operator characteristic analysis, a fixed or reversible defect within the apex by the qualitative method was the best criterion for coronary artery disease. However, although highly sensitive (79 and 85% by the qualitative and quantitative methods, respectively), an apical defect was neither specific (38 and 16%, respectively), nor accurate (57 and 46%, respectively). Perfusion abnormalities in the anterior wall and septum were also of limited diagnostic accuracy. Thus, modified interpretative criteria in patients with LBBB are not clinically useful in the assessment of left anterior descending artery disease

  13. Confinement facilities for handling plutonium

    International Nuclear Information System (INIS)

    Maraman, W.J.; McNeese, W.D.; Stafford, R.G.

    1975-01-01

    Plutonium handling on a multigram scale began in 1944. Early criteria, equipment, and techniques for confining contamination have been superseded by more stringent criteria and vastly improved equipment and techniques for in-process contamination control, effluent air cleaning and treatment of liquid wastes. This paper describes the evolution of equipment and practices to minimize exposure of workers and escape of contamination into work areas and into the environment. Early and current contamination controls are compared. (author)

  14. The aerodynamic design of an advanced rotor airfoil

    Science.gov (United States)

    Blackwell, J. A., Jr.; Hinson, B. L.

    1978-01-01

    An advanced rotor airfoil, designed utilizing supercritical airfoil technology and advanced design and analysis methodology is described. The airfoil was designed subject to stringent aerodynamic design criteria for improving the performance over the entire rotor operating regime. The design criteria are discussed. The design was accomplished using a physical plane, viscous, transonic inverse design procedure, and a constrained function minimization technique for optimizing the airfoil leading edge shape. The aerodynamic performance objectives of the airfoil are discussed.

  15. Analysis of blood donor pre-donation deferral in Dubai: characteristics and reasons

    OpenAIRE

    Al Shaer, Laila; Sharma, Ranjita; AbdulRahman, Mahera

    2017-01-01

    Laila Al Shaer,1 Ranjita Sharma,2 Mahera AbdulRahman2 1College of Medicine, Mohammed Bin Rashid University of Medicine and Health Sciences, Dubai, UAE; 2Dubai Health Authority, Dubai, UAE Background: To ensure an adequate and safe blood supply, it is crucial to select suitable donors according to stringent eligibility criteria. Understanding the reasons for donor deferral can help in planning more efficient recruitment strategies and evaluating donor selection criteria. This study aims to def...

  16. Criteria of GenCall score to edit marker data and methods to handle missing markers have an influence on accuracy of genomic predictions

    DEFF Research Database (Denmark)

    Edriss, Vahid; Guldbrandtsen, Bernt; Lund, Mogens Sandø

    2013-01-01

    The aim of this study was to investigate the effect of different strategies for handling low-quality or missing data on prediction accuracy for direct genomic values of protein yield, mastitis and fertility using a Bayesian variable model and a GBLUP model in the Danish Jersey population. The data...... contained 1071 Jersey bulls that were genotyped with the Illumina Bovine 50K chip. After preliminary editing, 39227 SNP remained in the dataset. Four methods to handle missing genotypes were: 1) BEAGLE: missing markers were imputed using Beagle 3.3 software, 2) COMMON: missing genotypes at a locus were...

  17. The accuracy of newly proposed warning signs in the third edition of Malaysian guideline on the management of dengue infection in adult

    Directory of Open Access Journals (Sweden)

    Gary Kim Kuan Low

    2016-08-01

    Full Text Available Objective: To evaluate the accuracy of persistent vomiting and persistent diarrhoea proposed in the Malaysian dengue guideline. Methods: The eligibility criteria were dengue patients with vomiting or/and diarrhoea at the earliest day of illness without other warning signs. Vomiting and diarrhoea categorised by three or more episodes over 24 h were considered as warning signs. Sensitivity, specificity, positive predictive value and negative predictive value were calculated. Results: There were a total of 479 patients, of whom 36 (7.5% got severe dengue and 443 (92.5% got dengue with warning signs. The overall accuracy ranged from 33.3% to 72.7% for sensitivity, 28.8% to 56.5% for specificity, 1.8% to 14.5% for positive predictive value and 88.5% to 96.3% for negative predictive value. There were 16 false negative. Conclusions: The newly proposed warning signs in the third edition of Malaysian dengue guideline may not be effective in predicting severe dengue.

  18. L-Band Radiometers Measuring Salinity From Space: Atmospheric Propagation Effects

    DEFF Research Database (Denmark)

    Skou, Niels; Hofman-Bang, Dorthe

    2005-01-01

    Microwave radiometers can measure sea surface salinity from space using L-band frequencies around 1.4 GHz. However, requirements to the accuracy of the measurements, in order to be satisfactory for the user, are so stringent that the influence of the intervening atmosphere cannot be neglected...

  19. Investigation of effective decision criteria for multiobjective optimization in IMRT.

    Science.gov (United States)

    Holdsworth, Clay; Stewart, Robert D; Kim, Minsun; Liao, Jay; Phillips, Mark H

    2011-06-01

    To investigate how using different sets of decision criteria impacts the quality of intensity modulated radiation therapy (IMRT) plans obtained by multiobjective optimization. A multiobjective optimization evolutionary algorithm (MOEA) was used to produce sets of IMRT plans. The MOEA consisted of two interacting algorithms: (i) a deterministic inverse planning optimization of beamlet intensities that minimizes a weighted sum of quadratic penalty objectives to generate IMRT plans and (ii) an evolutionary algorithm that selects the superior IMRT plans using decision criteria and uses those plans to determine the new weights and penalty objectives of each new plan. Plans resulting from the deterministic algorithm were evaluated by the evolutionary algorithm using a set of decision criteria for both targets and organs at risk (OARs). Decision criteria used included variation in the target dose distribution, mean dose, maximum dose, generalized equivalent uniform dose (gEUD), an equivalent uniform dose (EUD(alpha,beta) formula derived from the linear-quadratic survival model, and points on dose volume histograms (DVHs). In order to quantatively compare results from trials using different decision criteria, a neutral set of comparison metrics was used. For each set of decision criteria investigated, IMRT plans were calculated for four different cases: two simple prostate cases, one complex prostate Case, and one complex head and neck Case. When smaller numbers of decision criteria, more descriptive decision criteria, or less anti-correlated decision criteria were used to characterize plan quality during multiobjective optimization, dose to OARs and target dose variation were reduced in the final population of plans. Mean OAR dose and gEUD (a = 4) decision criteria were comparable. Using maximum dose decision criteria for OARs near targets resulted in inferior populations that focused solely on low target variance at the expense of high OAR dose. Target dose range, (D

  20. CT diagnostic criteria of branchial cysts

    International Nuclear Information System (INIS)

    Jend, H.H.; Jend-Rossmann, I.; Techentin, E.C.

    1984-01-01

    Although well known, the morphology of branchial cysts has not been sufficiently presented in CT literature. In the present case report, diagnostic criteria are given, such as typical site of occurrence, ductal extension towards the supratonsillar fossa, and cystic, but occasionally soft tissue density. Differential diagnosis is given for cases which cannot be classified according to these criteria. (orig.) [de

  1. Inelastic analysis acceptance criteria for radioactive material transportation containers

    International Nuclear Information System (INIS)

    Ammerman, D.J.; Ludwigsen, J.S.

    1993-01-01

    The design criteria currently used in the design of radioactive material (RAM) transportation containers are taken from the ASME Boiler and Pressure Vessel Code (ASME, 1992). These load-based criteria are ideally suited for pressure vessels where the loading is quasistatic and all stresses are in equilibrium with externally applied loads. For impact events, the use of load-based criteria is less supportable. Impact events tend to be energy controlled, and thus, energy-based acceptance criteria would appear to be more appropriate. Determination of an ideal design criteria depends on what behavior is desired. Currently there is not a design criteria for inelastic analysis for RAM nation packages that is accepted by the regulatory agencies. This lack of acceptance criteria is one of the major factors in limiting the use of inelastic analysis. In this paper inelastic analysis acceptance criteria based on stress and strain-energy density will be compared for two stainless steel test units subjected to impacts onto an unyielding target. Two different material models are considered for the inelastic analysis, a bilinear fit of the stress-strain curve and a power law hardening model that very closely follows the stress-strain curve. It is the purpose of this paper to stimulate discussion and research into the area of strain-energy density based inelastic analysis acceptance criteria

  2. Plugging criteria for WWER SG tubes

    Energy Technology Data Exchange (ETDEWEB)

    Papp, L.; Wilam, M. [Vitkovice NPP Services (Switzerland); Herman, M. [Vuje, Trnava (Slovakia)

    1997-12-31

    At operated Czech and Slovak nuclear power plants the 80 % criteria for crack or other bulk defect depth is used for steam generator heat exchanging tubes plugging. This criteria was accepted as the recommendation of designer of WWER steam generators. Verification of this criteria was the objective of experimental program performed by Vitkovice, J.S.C., UJV Rez, J.S.C. and Vuje Trnava, J.S.C .. Within this program the following factors were studied: (1) Influence of secondary water chemistry on defects initiation and propagation, (2) Statistical evaluation of corrosion defects progression at operated SG, and (3) Determination of critical pressure for tube rupture as a function of eddy current indications. In this presentation items (2) and (3) are considered.

  3. Plugging criteria for WWER SG tubes

    Energy Technology Data Exchange (ETDEWEB)

    Papp, L; Wilam, M [Vitkovice NPP Services (Switzerland); Herman, M [Vuje, Trnava (Slovakia)

    1998-12-31

    At operated Czech and Slovak nuclear power plants the 80 % criteria for crack or other bulk defect depth is used for steam generator heat exchanging tubes plugging. This criteria was accepted as the recommendation of designer of WWER steam generators. Verification of this criteria was the objective of experimental program performed by Vitkovice, J.S.C., UJV Rez, J.S.C. and Vuje Trnava, J.S.C .. Within this program the following factors were studied: (1) Influence of secondary water chemistry on defects initiation and propagation, (2) Statistical evaluation of corrosion defects progression at operated SG, and (3) Determination of critical pressure for tube rupture as a function of eddy current indications. In this presentation items (2) and (3) are considered.

  4. Accuracy Assessment and Analysis for GPT2

    Directory of Open Access Journals (Sweden)

    YAO Yibin

    2015-07-01

    Full Text Available GPT(global pressure and temperature is a global empirical model usually used to provide temperature and pressure for the determination of tropospheric delay, there are some weakness to GPT, these have been improved with a new empirical model named GPT2, which not only improves the accuracy of temperature and pressure, but also provides specific humidity, water vapor pressure, mapping function coefficients and other tropospheric parameters, and no accuracy analysis of GPT2 has been made until now. In this paper high-precision meteorological data from ECWMF and NOAA were used to test and analyze the accuracy of temperature, pressure and water vapor pressure expressed by GPT2, testing results show that the mean Bias of temperature is -0.59℃, average RMS is 3.82℃; absolute value of average Bias of pressure and water vapor pressure are less than 1 mb, GPT2 pressure has average RMS of 7 mb, and water vapor pressure no more than 3 mb, accuracy is different in different latitudes, all of them have obvious seasonality. In conclusion, GPT2 model has high accuracy and stability on global scale.

  5. The Criteria for Determining the Business Failure

    Directory of Open Access Journals (Sweden)

    Luminiţa TULEAŞCĂ

    2012-03-01

    Full Text Available The business failure represents a current problem in any economic and social context and, for this reason, the legislator has been concerned with the regulation of the criteria based on which to accurately determine the failure of a business man when the case. The liquidity test and the balance sheet test, or the insolvency and insolvability are the criteria for determining the business failure usually materialized by undergoing the bankruptcy procedure. The legislator’s option for one or another of these criteria represents a structural option depending on the legal culture of each state however, considering the economic causes and effects of the insolvability and insolvency, that tends to remove the unilateral, exclusivist options. This paper illustrates significant option differences between the criteria for determining the business failure in the member states of the European Union which is the most used criterion and, if these criteria can be equally used in the banking and insurance sector. Last but not least, the paper illustrates the meanings of insolvency and insolvability in different matters and different laws and the need to eliminate the reserve that the Romanian doctrine manifests towards the insolvability concept as a cause for bankruptcy.

  6. Design Criteria for Achieving Low Radon Concentration Indoors

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2016-01-01

    Design criteria for achieving low radon concentration indoors are presented in this paper. The paper suggests three design criteria. These criteria have to be considered at the early stage of the building design phase to meet the latest recommendations from the World Health Organization in most...... countries. The three design criteria are; first, establishing a radon barrier facing the ground; second, lowering the air pressure in the lower zone of the slab on ground facing downwards; third, diluting the indoor air with outdoor air. Three criteria when used can prevent radon infiltration and lower...... the radon concentration in the indoor air. In addition, a cheap and reliable method for measuring the radon concentration in the air indoors is described. The provision on radon in the Danish Building Regulations complies with the latest recommendations from the World Health Organization. Radon can cause...

  7. Accuracy in Optical Information Processing

    Science.gov (United States)

    Timucin, Dogan Aslan

    Low computational accuracy is an important obstacle for optical processors which blocks their way to becoming a practical reality and a serious challenger for classical computing paradigms. This research presents a comprehensive solution approach to the problem of accuracy enhancement in discrete analog optical information processing systems. Statistical analysis of a generic three-plane optical processor is carried out first, taking into account the effects of diffraction, interchannel crosstalk, and background radiation. Noise sources included in the analysis are photon, excitation, and emission fluctuations in the source array, transmission and polarization fluctuations in the modulator, and photoelectron, gain, dark, shot, and thermal noise in the detector array. Means and mutual coherence and probability density functions are derived for both optical and electrical output signals. Next, statistical models for a number of popular optoelectronic devices are studied. Specific devices considered here are light-emitting and laser diode sources, an ideal noiseless modulator and a Gaussian random-amplitude-transmittance modulator, p-i-n and avalanche photodiode detectors followed by electronic postprocessing, and ideal free-space geometrical -optics propagation and single-lens imaging systems. Output signal statistics are determined for various interesting device combinations by inserting these models into the general formalism. Finally, based on these special-case output statistics, results on accuracy limitations and enhancement in optical processors are presented. Here, starting with the formulation of the accuracy enhancement problem as (1) an optimal detection problem and (2) as a parameter estimation problem, the potential accuracy improvements achievable via the classical multiple-hypothesis -testing and maximum likelihood and Bayesian parameter estimation methods are demonstrated. Merits of using proper normalizing transforms which can potentially stabilize

  8. Seismic re-evaluation criteria for Bohunice V1 reconstruction

    International Nuclear Information System (INIS)

    Campbell, R.; Schlund, H.; Warnken, L.

    2001-01-01

    Bohunice V1 in Slovakia is a Russian designed two unit WWER 440, Model 230 Pressurized Water Reactor. The plant was not originally designed for earthquake. Subsequent and ongoing reassessments now confirm that the seismic hazard at the site is significant. EBO, the plant owner has contracted with a consortium lead by Siemens AG (REKON) to do major reconstruction of the plant to significantly enhance its safety systems by the addition of new systems and the upgrading of existing systems. As part of the reconstruction, a complete seismic assessment and upgrading is required for existing safety relevant structures, systems and components. It is not practical to conduct this reassessment and upgrading using criteria applied to new design of nuclear power plants. Alternate criteria may be used to achieve adequate safety goals. Utilities in the U.S. have faced several seismic issues with operating NPPs and to resolve these issues, alternate criteria have been developed which are much more cost effective than use of criteria for new design. These alternate criteria incorporate the knowledge obtained from investigation of the performance of equipment in major earthquakes and include provisions for structures and passive equipment to deform beyond the yield point, yet still provide their essential function. IAEA has incorporated features of these alternate criteria into draft Technical Guidelines for application to Bohunice V1 and V2. REKON has developed plant specific criteria and procedures for the Bohunice V1 reconstruction that incorporate major features of the U.S. developed alternate criteria, comply to local codes and which envelop the draft IAEA Technical Guidelines. Included in these criteria and procedures are comprehensive walkdown screening criteria for equipment, piping, HVAC and cable raceways, analytical criteria which include inelastic energy absorption factors defined on an element basis and testing criteria which include specific guidance on interpretation

  9. Design criteria for advanced reactors

    International Nuclear Information System (INIS)

    Dennielou, Y.

    1991-01-01

    Design criteria for advanced reactors are discussed, including safety aspects, site selection, problems related to maintenance and possibility of repairing or replacing structures or components of a nuclear power plant, the human factor considerations. Bearing in mind that some of these criteria are the subject of consensus at international level, the author suggests to establish a table of different operator requirements, to prepare a dossier on the comparison of input data for probabilistic risk analysis, to take into consideration the means to control a severe accident from the very start of the design

  10. Investigation on vibrational evaluation criteria for small-bore pipe

    International Nuclear Information System (INIS)

    Tsuji, Takashi; Maekawa, Akira; Takahashi, Tsuneo; Kato, Minoru; Torigoe, Yuichi

    2013-01-01

    The well-known organization such as API and SwRI in USA developed criteria for piping vibrational evaluation. These criteria are targeted for main pipes, but not branch pipes with small bore. In this study, applicability of criteria of API and SwRI to branch pipes was investigated. Vibration test using piping system with small bore branch pipe was conducted and amplitudes of vibrational stress and displacement were measured for various exciting force. In comparison of the measurements with the two criteria, though the criteria of API and SwRI were applicable to small bore branch pipe, they made too conservative evaluation. (author)

  11. Simplified Stability Criteria for Delayed Neutral Systems

    Directory of Open Access Journals (Sweden)

    Xinghua Zhang

    2014-01-01

    Full Text Available For a class of linear time-invariant neutral systems with neutral and discrete constant delays, several existing asymptotic stability criteria in the form of linear matrix inequalities (LMIs are simplified by using matrix analysis techniques. Compared with the original stability criteria, the simplified ones include fewer LMI variables, which can obviously reduce computational complexity. Simultaneously, it is theoretically shown that the simplified stability criteria and original ones are equivalent; that is, they have the same conservativeness. Finally, a numerical example is employed to verify the theoretic results investigated in this paper.

  12. A Stochastic Programming Approach with Improved Multi-Criteria Scenario-Based Solution Method for Sustainable Reverse Logistics Design of Waste Electrical and Electronic Equipment (WEEE

    Directory of Open Access Journals (Sweden)

    Hao Yu

    2016-12-01

    Full Text Available Today, the increased public concern about sustainable development and more stringent environmental regulations have become important driving forces for value recovery from end-of-life and end-of use products through reverse logistics. Waste electrical and electronic equipment (WEEE contains both valuable components that need to be recycled and hazardous substances that have to be properly treated or disposed of, so the design of a reverse logistics system for sustainable treatment of WEEE is of paramount importance. This paper presents a stochastic mixed integer programming model for designing and planning a generic multi-source, multi-echelon, capacitated, and sustainable reverse logistics network for WEEE management under uncertainty. The model takes into account both economic efficiency and environmental impacts in decision-making, and the environmental impacts are evaluated in terms of carbon emissions. A multi-criteria two-stage scenario-based solution method is employed and further developed in this study for generating the optimal solution for the stochastic optimization problem. The proposed model and solution method are validated through a numerical experiment and sensitivity analyses presented later in this paper, and an analysis of the results is also given to provide a deep managerial insight into the application of the proposed stochastic optimization model.

  13. Improved separability criteria via some classes of measurements

    Science.gov (United States)

    Shen, Shu-Qian; Li, Ming; Li-Jost, Xianqing; Fei, Shao-Ming

    2018-05-01

    The entanglement detection via local measurements can be experimentally implemented. Based on mutually unbiased measurements and general symmetric informationally complete positive-operator-valued measures, we present separability criteria for bipartite quantum states, which, by theoretical analysis, are stronger than the related existing criteria via these measurements. Two detailed examples are supplemented to show the efficiency of the presented separability criteria.

  14. Evaluation of the optimal diagnostic criteria for regional lymph node metastases of lung cancer on MR imaging by receiver operating characteristic curve

    International Nuclear Information System (INIS)

    Iwai, Naomichi; Yamaguchi, Yutaka

    1991-01-01

    MRI was performed in 78 primary lung cancer cases to evaluate the optimal diagnostic criteria for regional lymph node metastases. Receiver operating characteristic (ROC) curve analysis for 262 lymph nodes of the hilar and mediastinal regions showed that the optimal size criterion is 10 mm in the mean axis of nodal diameter. Employing this criterion, the diagnostic rates for hilar and mediastinal lymph nodes had a sensitivity of 75%, a specificity of 82%, and an overall accuracy of 79%. However, the diagnostic rates for subaortic, paraaortic, and hilar lymph nodes using the same criterion showed lower specificities than those for other nodes. It was suggested that evaluation by coronal section made the diagnosis for subaortic lymph nodes more precise. In the ROC curve analysis for each histologic type, it was thought that the optimal criterion for adenocarcinoma was 10 mm in the mean axis, and that the criteria for squamous cell carcinoma were 11 mm in the mean axis and 10 mm in the sort axis. (author)

  15. The process and criteria for diagnosing specific learning disorders: indications from the Consensus Conference promoted by the Italian National Institute of Health

    Directory of Open Access Journals (Sweden)

    Maria Luisa Lorusso

    2014-03-01

    Full Text Available A Consensus Conference on Specific Learning Disorders has been promoted by the Italian National Institute of Health (Istituto Superiore di Sanità, ISS. The Consensus Conference consisted in a systematic review of the international literature addressing the issues of diagnosis, risk factors and prognosis, treatment, service delivery and organizational models for Specific Learning Disorders (reading, spelling/writing, calculation. Selected papers were examined by a group of Evaluators and then discussed by a Scientific and Technical Committee, whose conclusions were examined and approved by a Jury Panel. The part on diagnostic issues is presented here, encompassing a systematic discussion of the use and appropriateness of diagnostic criteria, parameters, tasks and psychometric indexes as illustrated in the literature, and providing recommendations for clinical practice. Special attention has been devoted to the collection, analysis and discussion of published data concerning languages with transparent orthography. Controversial issues such as discrepancy criteria, role of reading comprehension and importance of accuracy and fluency are discussed.

  16. Identification of multi-criteria for supplier selection in IT project outsourcing

    Science.gov (United States)

    Fusiripong, Prashaya; Baharom, Fauziah; Yusof, Yuhanis

    2017-10-01

    In the increasing global business competitiveness, most organizations have attempted to determine the suitable external parties to support their core and non-core competency, particularly, in IT project outsourcing. The IT supplier selection is required to apply multi-criteria which comprised tangible criteria and intangible criteria in consider optimal IT supplier. Most researches attempted to identify optimal criteria for selecting IT supplier, however, the criteria cannot be the considered common criteria support the variety of IT outsourcing. Therefore, the study aimed to identify a common set of criteria being used in the various types of IT outsourcing. The common criteria are constructed by multi-criteria and success criteria, which were collected by literature review with comprehensive and comparative approach. Consequently, the researchers are able to identify a common set of criteria adopted in the variety of selection problem IT outsourcing supplier.

  17. Accuracy, Authenticity, Fidelity: Aesthetic Realism, the "Deficit Model," and the Public Understanding of Science.

    Science.gov (United States)

    Vidal, Fernando

    2018-03-01

    Argument "Deficit model" designates an outlook on the public understanding and communication of science that emphasizes scientific illiteracy and the need to educate the public. Though criticized, it is still widespread, especially among scientists. Its persistence is due not only to factors ranging from scientists' training to policy design, but also to the continuance of realism as an aesthetic criterion. This article examines the link between realism and the deficit model through discussions of neurology and psychiatry in fiction film, as well as through debates about historical movies and the cinematic adaptation of literature. It shows that different values and criteria tend to dominate the realist stance in different domains: accuracy for movies concerning neurology and psychiatry, authenticity for the historical film, and fidelity for adaptations of literature. Finally, contrary to the deficit model, it argues that the cinema is better characterized by a surplus of meaning than by informational shortcomings.

  18. Evaluation of Urban Planning Projects Criteria Using Fuzzy AHP Technique

    Directory of Open Access Journals (Sweden)

    Walid Mustafa Kamas

    2017-05-01

    Full Text Available In this research, Fuzzy Analytic Hierarchy Process technique is applied (Fuzzy AHP which is one of multi-criteria decision making techniques to evaluate the criteria for urban planning projects, the project of developing master plan of Al-Muqdadiyah city to 2035 has been chosen as a case study. The researcher prepared a list of criteria in addition to the authorized departments criteria and previous researches in order to choose optimized master plan according to these criteria. This research aims at employing the foundations of (Fuzzy AHP technique in evaluating urban planning criteria precisely and flexible. The results of the data analysis to the individuals of the sample who are specialists, in this aspect. The land use criteria are more important than the rest of the criteria in these projects, where it received the relative importance with percentile (42.1 %.

  19. Combined Scintigraphy and Tumor Marker Analysis Predicts Unfavorable Histopathology of Neuroblastic Tumors with High Accuracy.

    Directory of Open Access Journals (Sweden)

    Wolfgang Peter Fendler

    Full Text Available Our aim was to improve the prediction of unfavorable histopathology (UH in neuroblastic tumors through combined imaging and biochemical parameters.123I-MIBG SPECT and MRI was performed before surgical resection or biopsy in 47 consecutive pediatric patients with neuroblastic tumor. Semi-quantitative tumor-to-liver count-rate ratio (TLCRR, MRI tumor size and margins, urine catecholamine and NSE blood levels of neuron specific enolase (NSE were recorded. Accuracy of single and combined variables for prediction of UH was tested by ROC analysis with Bonferroni correction.34 of 47 patients had UH based on the International Neuroblastoma Pathology Classification (INPC. TLCRR and serum NSE both predicted UH with moderate accuracy. Optimal cut-off for TLCRR was 2.0, resulting in 68% sensitivity and 100% specificity (AUC-ROC 0.86, p < 0.001. Optimal cut-off for NSE was 25.8 ng/ml, resulting in 74% sensitivity and 85% specificity (AUC-ROC 0.81, p = 0.001. Combination of TLCRR/NSE criteria reduced false negative findings from 11/9 to only five, with improved sensitivity and specificity of 85% (AUC-ROC 0.85, p < 0.001.Strong 123I-MIBG uptake and high serum level of NSE were each predictive of UH. Combined analysis of both parameters improved the prediction of UH in patients with neuroblastic tumor. MRI parameters and urine catecholamine levels did not predict UH.

  20. Automatic Sleep Scoring in Normals and in Individuals with Neurodegenerative Disorders According to New International Sleep Scoring Criteria

    DEFF Research Database (Denmark)

    Jensen, Peter S.; Sørensen, Helge Bjarup Dissing; Leonthin, Helle

    2010-01-01

    The aim of this study was to develop a fully automatic sleep scoring algorithm on the basis of a reproduction of new international sleep scoring criteria from the American Academy of Sleep Medicine. A biomedical signal processing algorithm was developed, allowing for automatic sleep depth....... Based on an observed reliability of the manual scorer of 92.5% (Cohen's Kappa: 0.87) in the normal group and 85.3% (Cohen's Kappa: 0.73) in the abnormal group, this study concluded that although the developed algorithm was capable of scoring normal sleep with an accuracy around the manual interscorer...... reliability, it failed in accurately scoring abnormal sleep as encountered for the Parkinson disease/multiple system atrophy patients....