WorldWideScience

Sample records for stride length measurement

  1. Stride length: measuring its instantaneous value

    International Nuclear Information System (INIS)

    Campiglio, G C; Mazzeo, J R

    2007-01-01

    Human gait has been studied from different viewpoints: kinematics, dynamics, sensibility and others. Many of its characteristics still remain open to research, both for normal gait and for pathological gait. Objective measures of some of its most significant spatial/temporal parameters are important in this context. Stride length, one of these parameters, is defined as the distance between two consecutive contacts of one foot with ground. On this work we present a device designed to provide automatic measures of stride length. Its features make it particularly appropriate for the evaluation of pathological gait

  2. Pedestrian Stride Length Estimation from IMU Measurements and ANN Based Algorithm

    Directory of Open Access Journals (Sweden)

    Haifeng Xing

    2017-01-01

    Full Text Available Pedestrian dead reckoning (PDR can be used for continuous position estimation when satellite or other radio signals are not available, and the accuracy of the stride length measurement is important. Current stride length estimation algorithms, including linear and nonlinear models, consider a few variable factors, and some rely on high precision and high cost equipment. This paper puts forward a stride length estimation algorithm based on a back propagation artificial neural network (BP-ANN, using a consumer-grade inertial measurement unit (IMU; it then discusses various factors in the algorithm. The experimental results indicate that the error of the proposed algorithm in estimating the stride length is approximately 2%, which is smaller than that of the frequency and nonlinear models. Compared with the latter two models, the proposed algorithm does not need to determine individual parameters in advance if the trained neural net is effective. It can, thus, be concluded that this algorithm shows superior performance in estimating pedestrian stride length.

  3. The importance of stride length and stride frequency in middle ...

    African Journals Online (AJOL)

    ... also found that the better runners have faster stride frequencies and that provincial middle distance runners use lower stride frequencies than international middle distance runners. Key Words: Biomechanics, stride length, stride frequency, maximum oxygen consumption, leg length, middle distance runners, road runners.

  4. Stride length determination during overground running using a single foot-mounted inertial measurement unit.

    Science.gov (United States)

    Brahms, C Markus; Zhao, Yang; Gerhard, David; Barden, John M

    2018-02-10

    From a research perspective, detailed knowledge about stride length (SL) is important for coaches, clinicians and researchers because together with stride rate it determines the speed of locomotion. Moreover, individual SL vectors represent the integrated output of different biomechanical determinants and as such provide valuable insight into the control of running gait. In recent years, several studies have tried to estimate SL using body-mounted inertial measurement units (IMUs) and have reported promising results. However, many studies have used systems based on multiple sensors or have only focused on estimating SL for walking. Here we test the concurrent validity of a single foot-mounted, 9-degree of freedom IMU to estimate SL for running. We employed a running-specific, Kalman filter based zero-velocity update (ZUPT) algorithm to calculate individual SL vectors with the IMU and compared the results to SLs that were simultaneously recorded by a 6-camera 3D motion capture system. The results showed that the analytical procedures were able to successfully identify all strides that were recorded by the camera system and that excellent levels of absolute agreement (ICC(3,1) = 0.955) existed between the two methods. The findings demonstrate that individual SL vectors can be accurately estimated with a single foot-mounted IMU when running in a controlled laboratory setting. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Stride length asymmetry in split-belt locomotion.

    Science.gov (United States)

    Hoogkamer, Wouter; Bruijn, Sjoerd M; Duysens, Jacques

    2014-01-01

    The number of studies utilizing a split-belt treadmill is rapidly increasing in recent years. This has led to some confusion regarding the definitions of reported gait parameters. The purpose of this paper is to clearly present the definitions of the gait parameters that are commonly used in split-belt treadmill studies. We argue that the modified version of stride length for split-belt gait, which is different from the standard definition of stride length and actually is a measure of limb excursion, should be referred to as 'limb excursion' in future studies. Furthermore, the symmetry of stride length and stride time is specifically addressed. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Select injury-related variables are affected by stride length and foot strike style during running.

    Science.gov (United States)

    Boyer, Elizabeth R; Derrick, Timothy R

    2015-09-01

    Some frontal plane and transverse plane variables have been associated with running injury, but it is not known if they differ with foot strike style or as stride length is shortened. To identify if step width, iliotibial band strain and strain rate, positive and negative free moment, pelvic drop, hip adduction, knee internal rotation, and rearfoot eversion differ between habitual rearfoot and habitual mid-/forefoot strikers when running with both a rearfoot strike (RFS) and a mid-/forefoot strike (FFS) at 3 stride lengths. Controlled laboratory study. A total of 42 healthy runners (21 habitual rearfoot, 21 habitual mid-/forefoot) ran overground at 3.35 m/s with both a RFS and a FFS at their preferred stride lengths and 5% and 10% shorter. Variables did not differ between habitual groups. Step width was 1.5 cm narrower for FFS, widening to 0.8 cm as stride length shortened. Iliotibial band strain and strain rate did not differ between foot strikes but decreased as stride length shortened (0.3% and 1.8%/s, respectively). Pelvic drop was reduced 0.7° for FFS compared with RFS, and both pelvic drop and hip adduction decreased as stride length shortened (0.8° and 1.5°, respectively). Peak knee internal rotation was not affected by foot strike or stride length. Peak rearfoot eversion was not different between foot strikes but decreased 0.6° as stride length shortened. Peak positive free moment (normalized to body weight [BW] and height [h]) was not affected by foot strike or stride length. Peak negative free moment was -0.0038 BW·m/h greater for FFS and decreased -0.0004 BW·m/h as stride length shortened. The small decreases in most variables as stride length shortened were likely associated with the concomitant wider step width. RFS had slightly greater pelvic drop, while FFS had slightly narrower step width and greater negative free moment. Shortening one's stride length may decrease or at least not increase propensity for running injuries based on the variables

  7. Effects of socks which improved foot sensation on velocity and stride length of elderly subjects crossing obstacles.

    Science.gov (United States)

    Yoo, Won-Gyu

    2015-08-01

    [Purpose] We developed socks which improve foot sensation and investigated their effect on the velocity and stride length of elderly women crossing obstacles. [Subjects] Ten community-dwelling, elderly women who could walk independently were recruited. [Methods] We measured velocity and stride length using the GAITRite system while the participants crossed obstacles under three conditions: barefoot, wearing ordinary socks, and wearing the socks which improve foot sensation. [Results] Velocity and stride length in bare feet and when wearing the sense-improving socks increased significantly compared to their values when wearing standard socks. Velocity and stride length did not differ between the bare foot and improved sock conditions. [Conclusion] Wearing socks helps protect the foot, but can decrease foot sensory input. Therefore, the socks which improve foot sensation were useful for preventing falls and protecting the feet of the elderly women while they crossed obstacles.

  8. Running-specific, periodized strength training attenuates loss of stride length during intense endurance running.

    Science.gov (United States)

    Esteve-Lanao, Jonathan; Rhea, Matthew R; Fleck, Steven J; Lucia, Alejandro

    2008-07-01

    The purpose of this study was to determine the effects of a running-specific, periodized strength training program (performed over the specific period [8 weeks] of a 16-week macrocycle) on endurance-trained runners' capacity to maintain stride length during running bouts at competitive speeds. Eighteen well-trained middle-distance runners completed the study (personal bests for 1500 and 5000 m of 3 minutes 57 seconds +/- 12 seconds and 15 minutes 24 seconds +/- 36 seconds). They were randomly assigned to each of the following groups (6 per group): periodized strength group, performing a periodized strength training program over the 8-week specific (intervention) period (2 sessions per week); nonperiodized strength group, performing the same strength training exercises as the periodized group over the specific period but with no week-to-week variations; and a control group, performing no strength training at all during the specific period. The percentage of loss in the stride length (cm)/speed (m.s) (SLS) ratio was measured by comparing the mean SLS during the first and third (last) group of the total repetitions, respectively, included in each of the interval training sessions performed at race speeds during the competition period that followed the specific period. Significant differences (p endurance runners during fatiguing running bouts.

  9. Increased delivery stride length places greater loads on the ankle joint in elite male cricket fast bowlers.

    Science.gov (United States)

    Spratford, Wayne; Hicks, Amy

    2014-01-01

    The purpose of this study was to investigate the effect stride length has on ankle biomechanics of the leading leg with reference to the potential risk of injury in cricket fast bowlers. Ankle joint kinematic and kinetic data were collected from 51 male fast bowlers during the stance phase of the final delivery stride. The bowling cohort comprised national under-19, first class and international-level athletes. Bowlers were placed into either Short, Average or Long groups based on final stride length, allowing statistical differences to be measured. A multivariate analysis of variance with a Bonferroni post-hoc correction (α = 0.05) revealed significant differences between peak plantarflexion angles (Short-Long P = 0.005, Average and Long P = 0.04) and negative joint work (Average-Long P = 0.026). This study highlighted that during fast bowling the ankle joint of the leading leg experiences high forces under wide ranges of movement. As stride length increases, greater amounts of negative work and plantarflexion are experienced. These increases place greater loads on the ankle joint and move the foot into positions that make it more susceptible to injuries such as posterior impingement syndrome.

  10. The Effect of the Accelerometer Operating Range on Biomechanical Parameters: Stride Length, Velocity, and Peak Tibial Acceleration during Running

    Directory of Open Access Journals (Sweden)

    Christian Mitschke

    2018-01-01

    Full Text Available Previous studies have used accelerometers with various operating ranges (ORs when measuring biomechanical parameters. However, it is still unclear whether ORs influence the accuracy of running parameters, and whether the different stiffnesses of footwear midsoles influence this accuracy. The purpose of the present study was to systematically investigate the influence of OR on the accuracy of stride length, running velocity, and on peak tibial acceleration. Twenty-one recreational heel strike runners ran on a 15-m indoor track at self-selected running speeds in three footwear conditions (low to high midsole stiffness. Runners were equipped with an inertial measurement unit (IMU affixed to the heel cup of the right shoe and with a uniaxial accelerometer at the right tibia. Accelerometers (at the tibia and included in the IMU with a high OR of ±70 g were used as the reference and the data were cut at ±32, ±16, and at ±8 g in post-processing, before calculating parameters. The results show that the OR influenced the outcomes of all investigated parameters, which were not influenced by tested footwear conditions. The lower ORs were associated with an underestimation error for all biomechanical parameters, which increased noticeably with a decreasing OR. It can be concluded that accelerometers with a minimum OR of ±32 g should be used to avoid inaccurate measurements.

  11. Walking training with cueing of cadence improves walking speed and stride length after stroke more than walking training alone: a systematic review.

    Science.gov (United States)

    Nascimento, Lucas R; de Oliveira, Camila Quel; Ada, Louise; Michaelsen, Stella M; Teixeira-Salmela, Luci F

    2015-01-01

    After stroke, is walking training with cueing of cadence superior to walking training alone in improving walking speed, stride length, cadence and symmetry? Systematic review with meta-analysis of randomised or controlled trials. Adults who have had a stroke. Walking training with cueing of cadence. Four walking outcomes were of interest: walking speed, stride length, cadence and symmetry. This review included seven trials involving 211 participants. Because one trial caused substantial statistical heterogeneity, meta-analyses were conducted with and without this trial. Walking training with cueing of cadence improved walking speed by 0.23 m/s (95% CI 0.18 to 0.27, I(2)=0%), stride length by 0.21 m (95% CI 0.14 to 0.28, I(2)=18%), cadence by 19 steps/minute (95% CI 14 to 23, I(2)=40%), and symmetry by 15% (95% CI 3 to 26, random effects) more than walking training alone. This review provides evidence that walking training with cueing of cadence improves walking speed and stride length more than walking training alone. It may also produce benefits in terms of cadence and symmetry of walking. The evidence appears strong enough to recommend the addition of 30 minutes of cueing of cadence to walking training, four times a week for 4 weeks, in order to improve walking in moderately disabled individuals with stroke. PROSPERO (CRD42013005873). Copyright © 2014 Australian Physiotherapy Association. Published by Elsevier B.V. All rights reserved.

  12. Validation of distal limb mounted inertial-measurement-unit sensors for stride detection in Warmblood horses at walk and trot

    NARCIS (Netherlands)

    Serra Braganca, Filipe; Bosch, S; Voskamp, J P; Marin-Perianu, M; Van der Zwaag, B J; Vernooij, J C M; van Weeren, P R; Back, W

    BACKGROUND: Inertial-measurement-unit (IMU)-sensor-based techniques are becoming more popular in horses as a tool for objective locomotor assessment. OBJECTIVES: To describe, evaluate and validate a method of stride detection and quantification at walk and trot using distal limb mounted IMU-sensors.

  13. Validation of distal limb mounted inertial measurement unit sensors for stride detection in Warmblood horses at walk and trot

    NARCIS (Netherlands)

    Braganca, F.M.; Bosch, S.; Voskamp, J.P.; Marin Perianu, Mihai; van der Zwaag, B.J.; Vernooij, J.C.; van Weeren, P.R.; Back, W.

    2016-01-01

    Background: Inertial measurement unit (IMU) sensor-based techniques are becoming more popular in horses as a tool for objective locomotor assessment. Objectives: To describe, evaluate and validate a method of stride detection and quantification at walk and trot using distal limb mounted IMU sensors.

  14. Changes in timing of muscle contractions and running economy with altered stride pattern during running.

    Science.gov (United States)

    Connick, Mark J; Li, Francois-Xavier

    2014-01-01

    Large alterations to the preferred running stride decrease running economy, and shorter strides increase leg muscle activity. However, the effect of altered strides on the timing of leg muscle activation is not known. The aim of this study was to evaluate the impact of moderate alterations to the running stride on running economy and the timing of biceps femoris (BF), vastus lateralis (VL) and gastrocnemius (GAST) muscle contractions. The preferred stride pattern for eleven trained male runners was measured prior to a separate visit where participants ran for bouts of 5 min whilst synchronising foot contacts to a metronome signal which was tuned to (1) the preferred stride, and (2) frequencies which related to ± 8% and ± 4% of the preferred stride length. Running economy was measured at each stride pattern along with electromyography and three-dimensional kinematics to estimate onset and offset of muscle contractions for each muscle. Running economy was greatest at the preferred stride length. However, a quadratic fit to the data was optimised at a stride which was 2.9% shorter than preferred. Onset and offset of BF and VL muscle contractions occurred earlier with shorter than preferred strides. We detected no changes to the timing of muscle contractions with longer than preferred strides and no changes to GAST muscle contractions. The results suggest that runners optimise running economy with a stride length that is close to, but shorter than, the preferred stride, and that timing of BF and VL muscle contractions change with shorter than preferred strides. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Overview of bunch length measurements

    International Nuclear Information System (INIS)

    Lumpkin, A. H.

    1999-01-01

    An overview of particle and photon beam bunch length measurements is presented in the context of free-electron laser (FEL) challenges. Particle-beam peak current is a critical factor in obtaining adequate FEL gain for both oscillators and self-amplified spontaneous emission (SASE) devices. Since measurement of charge is a standard measurement, the bunch length becomes the key issue for ultrashort bunches. Both time-domain and frequency-domain techniques are presented in the context of using electromagnetic radiation over eight orders of magnitude in wavelength. In addition, the measurement of microbunching in a micropulse is addressed

  16. CEBAF Upgrade Bunch Length Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Mahmoud [Old Dominion Univ., Norfolk, VA (United States)

    2016-05-01

    Many accelerators use short electron bunches and measuring the bunch length is important for efficient operations. CEBAF needs a suitable bunch length because bunches that are too long will result in beam interruption to the halls due to excessive energy spread and beam loss. In this work, bunch length is measured by invasive and non-invasive techniques at different beam energies. Two new measurement techniques have been commissioned; a harmonic cavity showed good results compared to expectations from simulation, and a real time interferometer is commissioned and first checkouts were performed. Three other techniques were used for measurements and comparison purposes without modifying the old procedures. Two of them can be used when the beam is not compressed longitudinally while the other one, the synchrotron light monitor, can be used with compressed or uncompressed beam.

  17. Validation of distal limb mounted inertial measurement unit sensors for stride detection in Warmblood horses at walk and trot.

    Science.gov (United States)

    Bragança, F M; Bosch, S; Voskamp, J P; Marin-Perianu, M; Van der Zwaag, B J; Vernooij, J C M; van Weeren, P R; Back, W

    2017-07-01

    Inertial measurement unit (IMU) sensor-based techniques are becoming more popular in horses as a tool for objective locomotor assessment. To describe, evaluate and validate a method of stride detection and quantification at walk and trot using distal limb mounted IMU sensors. Prospective validation study comparing IMU sensors and motion capture with force plate data. A total of seven Warmblood horses equipped with metacarpal/metatarsal IMU sensors and reflective markers for motion capture were hand walked and trotted over a force plate. Using four custom built algorithms hoof-on/hoof-off timing over the force plate were calculated for each trial from the IMU data. Accuracy of the computed parameters was calculated as the mean difference in milliseconds between the IMU or motion capture generated data and the data from the force plate, precision as the s.d. of these differences and percentage of error with accuracy of the calculated parameter as a percentage of the force plate stance duration. Accuracy, precision and percentage of error of the best performing IMU algorithm for stance duration at walk were 28.5, 31.6 ms and 3.7% for the forelimbs and -5.5, 20.1 ms and -0.8% for the hindlimbs, respectively. At trot the best performing algorithm achieved accuracy, precision and percentage of error of -27.6/8.8 ms/-8.4% for the forelimbs and 6.3/33.5 ms/9.1% for the hindlimbs. The described algorithms have not been assessed on different surfaces. Inertial measurement unit technology can be used to determine temporal kinematic stride variables at walk and trot justifying its use in gait and performance analysis. However, precision of the method may not be sufficient to detect all possible lameness-related changes. These data seem promising enough to warrant further research to evaluate whether this approach will be useful for appraising the majority of clinically relevant gait changes encountered in practice. © 2016 The Authors. Equine Veterinary Journal published by

  18. Comparison of accelerometry stride time calculation methods.

    Science.gov (United States)

    Norris, Michelle; Kenny, Ian C; Anderson, Ross

    2016-09-06

    Inertial sensors such as accelerometers and gyroscopes can provide a multitude of information on running gait. Running parameters such as stride time and ground contact time can all be identified within tibial accelerometry data. Within this, stride time is a popular parameter of interest, possibly due to its role in running economy. However, there are multiple methods utilised to derive stride time from tibial accelerometry data, some of which may offer complications when implemented on larger data files. Therefore, the purpose of this study was to compare previously utilised methods of stride time derivation to an original proposed method, utilising medio-lateral tibial acceleration data filtered at 2Hz, allowing for greater efficiency in stride time output. Tibial accelerometry data from six participants training for a half marathon were utilised. One right leg run was randomly selected for each participant, in which five consecutive running stride times were calculated. Four calculation methods were employed to derive stride time. A repeated measures analysis of variance (ANOVA) identified no significant difference in stride time between stride time calculation methods (p=1.00), whilst intra-class coefficient values (all >0.95) and coefficient of variance values (all method possibly offers a simplified technique for stride time output during running gait analysis. This method may be less influenced by "double peak" error and minor fluctuations within the data, allowing for accurate and efficient automated data output in both real time and post processing. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Stride angle as a novel indicator of running economy in well-trained runners.

    Science.gov (United States)

    Santos-Concejero, Jordan; Tam, Nicholas; Granados, Cristina; Irazusta, Jon; Bidaurrazaga-Letona, Iraia; Zabala-Lili, Jon; Gil, Susana M

    2014-07-01

    The main purpose of this study was to investigate the relationship between a novel biomechanical variable, the stride angle, and running economy (RE) in a homogeneous group of long-distance athletes. Twenty-five well-trained male runners completed 4-minute running stages on a treadmill at different set velocities. During the test, biomechanical variables such as stride angle, swing time, ground contact time, stride length, stride frequency, and the different sub-phases of ground contact were recorded using an optical measurement system. VO2 values at velocities below the lactate threshold were measured to calculate RE. Stride angle was negatively correlated with RE at every speed (p contact time and running performance according to the best 10-km race time (p ≤ 0.05, moderate and large effect sizes). Last, stride angle was correlated with ground contact time at every speed (p angle allows runners to minimize contact time during ground contact, whereby facilitating a better RE. Coaches and/or athletes may find stride angle a useful and easily obtainable measure to track and make alterations to running technique, because changes in stride angle may influence the energy cost of running and lead to improved performance.

  20. Influence of contextual task constraints on preferred stride parameters and their variabilities during human walking.

    Science.gov (United States)

    Ojeda, Lauro V; Rebula, John R; Kuo, Arthur D; Adamczyk, Peter G

    2015-10-01

    Walking is not always a free and unencumbered task. Everyday activities such as walking in pairs, in groups, or on structured walkways can limit the acceptable gait patterns, leading to motor behavior that differs from that observed in more self-selected gait. Such different contexts may lead to gait performance different than observed in typical laboratory experiments, for example, during treadmill walking. We sought to systematically measure the impact of such task constraints by comparing gait parameters and their variability during walking in different conditions over-ground, and on a treadmill. We reconstructed foot motion from foot-mounted inertial sensors, and characterized forward, lateral and angular foot placement while subjects walked over-ground in a straight hallway and on a treadmill. Over-ground walking was performed in three variations: with no constraints (self-selected, SS); while deliberately varying walking speed (self-varied, SV); and while following a toy pace car programmed to vary speed (externally-varied, EV). We expected that these conditions would exhibit a statistically similar relationship between stride length and speed, and between stride length and stride period. We also expected treadmill walking (TM) would differ in two ways: first, that variability in stride length and stride period would conform to a constant-speed constraint opposite in slope from the normal relationship; and second, that stride length would decrease, leading to combinations of stride length and speed not observed in over-ground conditions. Results showed that all over-ground conditions used similar stride length-speed relationships, and that variability in treadmill walking conformed to a constant-speed constraint line, as expected. Decreased stride length was observed in both TM and EV conditions, suggesting adaptations due to heightened awareness or to prepare for unexpected changes or problems. We also evaluated stride variability in constrained and

  1. Martian Length of Day Measurements from Rovers

    Science.gov (United States)

    Eubanks, T. M.; Bills, B.

    2012-06-01

    Changes in the Martian Length of Day (LOD) can be determined at a scientifically use level by a combination of regular (but not necessarily frequent) range and Doppler measurements from Earth and dead reckoning in a Kalman filter.

  2. Maximum swimming speeds of sailfish and three other large marine predatory fish species based on muscle contraction time and stride length

    DEFF Research Database (Denmark)

    Svendsen, Morten Bo Søndergaard; Domenici, Paolo; Marras, Stefano

    2016-01-01

    Billfishes are considered to be among the fastest swimmers in the oceans. Previous studies have estimated maximum speed of sailfish and black marlin at around 35 m s(-1) but theoretical work on cavitation predicts that such extreme speed is unlikely. Here we investigated maximum speed of sailfish......, and three other large marine pelagic predatory fish species, by measuring the twitch contraction time of anaerobic swimming muscle. The highest estimated maximum swimming speeds were found in sailfish (8.3±1.4 m s(-1)), followed by barracuda (6.2±1.0 m s(-1)), little tunny (5.6±0.2 m s(-1)) and dorado (4...

  3. Bunch Length Measurements in SPEAR3

    Energy Technology Data Exchange (ETDEWEB)

    Corbett, W.J.; Fisher, A.; Huang, X.; Safranek, J.; Sebek, J.; /SLAC; Lumpkin, A.; /Argonne; Sannibale, F.; /LBL, Berkeley; Mok, W.; /Unlisted

    2007-11-28

    A series of bunch length measurements were made in SPEAR3 for two different machine optics. In the achromatic optics the bunch length increases from the low-current value of 16.6ps rms to about 30ps at 25ma/bunch yielding an inductive impedance of -0.17{Omega}. Reducing the momentum compaction factor by a factor of {approx}60 [1] yields a low-current bunch length of {approx}4ps rms. In this paper we review the experimental setup and results.

  4. Maximum swimming speeds of sailfish and three other large marine predatory fish species based on muscle contraction time and stride length: a myth revisited

    Directory of Open Access Journals (Sweden)

    Morten B. S. Svendsen

    2016-10-01

    Full Text Available Billfishes are considered to be among the fastest swimmers in the oceans. Previous studies have estimated maximum speed of sailfish and black marlin at around 35 m s−1 but theoretical work on cavitation predicts that such extreme speed is unlikely. Here we investigated maximum speed of sailfish, and three other large marine pelagic predatory fish species, by measuring the twitch contraction time of anaerobic swimming muscle. The highest estimated maximum swimming speeds were found in sailfish (8.3±1.4 m s−1, followed by barracuda (6.2±1.0 m s−1, little tunny (5.6±0.2 m s−1 and dorado (4.0±0.9 m s−1; although size-corrected performance was highest in little tunny and lowest in sailfish. Contrary to previously reported estimates, our results suggest that sailfish are incapable of exceeding swimming speeds of 10-15 m s−1, which corresponds to the speed at which cavitation is predicted to occur, with destructive consequences for fin tissues.

  5. Distance and Cable Length Measurement System

    Science.gov (United States)

    Hernández, Sergio Elias; Acosta, Leopoldo; Toledo, Jonay

    2009-01-01

    A simple, economic and successful design for distance and cable length detection is presented. The measurement system is based on the continuous repetition of a pulse that endlessly travels along the distance to be detected. There is a pulse repeater at both ends of the distance or cable to be measured. The endless repetition of the pulse generates a frequency that varies almost inversely with the distance to be measured. The resolution and distance or cable length range could be adjusted by varying the repetition time delay introduced at both ends and the measurement time. With this design a distance can be measured with centimeter resolution using electronic system with microsecond resolution, simplifying classical time of flight designs which require electronics with picosecond resolution. This design was also applied to position measurement. PMID:22303169

  6. Measuring the orbit length of the Tevatron

    International Nuclear Information System (INIS)

    Kerns, C.; Kerns, Q.; Miller, H.

    1985-06-01

    The orbit length in the Tevatron was measured when coasting beam was first obtained. The method was time-of-flight, using a vernier phase comparison between beam pickup signals and a synthesizer sine wave. Some effort was spent making a stable phase detector so that it would not be a limiting factor. The results exhibited a repeatability of a few Hz at 53 MHz, corresponding to a mean radius measurement to 0.1 mm. 5 refs., 4 figs

  7. Measure it! fun with length and distance

    CERN Document Server

    First, Rachel

    2016-01-01

    Make math fun with Measure It! Fun photographs, colorful graphics, and simple text are used to teach young readers basic math concepts. From Metric System to Standard System this book will help kids develop the skills they need. A simple activity at the end of the book encourages kids to put length and distance to use! Aligned to Common Core standards and correlated to state standards. Sandcastle is an imprint of Abdo Publishing, a division of ABDO.

  8. Smith Purcell Radiation Bunch-Length Measurement

    CERN Document Server

    Korbly, Stephen; Marsh, Roark A; Temkin, Richard J

    2005-01-01

    Measurements of Coherent Smith-Purcell Radiation (SPR) were performed at the 17 GHz high-gradient accelerator built by Haimson Research Corporation at the MIT Plasma Science and Fusion Center. SPR is a promising radiation source because the radiation intensity is enhanced by the number of grating periods. The radiation produced obeys the SP resonance condition correlating the radiation frequency at each observation angle, allowing SPR to be exploited as a bunch-length measurement. For a 15 MeV 150 mA 125 ns beam in short and long pulse modes, bunch-lengths of 0.6 ps and 1 ps were measured with this method, respectively, with an error of ± 0.1 ps. Frequency measurements were also performed using a double Heterodyne system. Heterodyne measurements revealed frequency-locking, which gave a power level enhancement of 1000 at integer multiples of the Accelerator RF frequency. Frequencies up to 514 GHz were measured with a bandwidth of 25 MHz.

  9. Bunch Length Measurements using Coherent Radiation

    CERN Document Server

    Ischebeck, Rasmus; Barnes, Christopher; Blumenfeld, Ian; Clayton, Chris; Decker, Franz Josef; Deng, Suzhi; Hogan, Mark; Huang Cheng Kun; Iverson, Richard; Johnson, Devon K; Krejcik, Patrick; Lu, Wei; Marsh, Kenneth; Oz, Erdem; Siemann, Robert; Walz, Dieter

    2005-01-01

    The accelerating field that can be obtained in a beam-driven plasma wakefield accelerator depends on the current of the electron beam that excites the wake. In the E-167 experiment, a peak current above 10kA will be delivered at a particle energy of 28GeV. The bunch has a length of a few ten micrometers and several methods are used to measure its longitudinal profile. Among these, autocorrelation of coherent transition radiation (CTR) is employed. The beam passes a thin metallic foil, where it emits transition radiation. For wavelengths greater than the bunch length, this transition radiation is emitted coherently. This amplifies the long-wavelength part of the spectrum. A scanning Michelson interferometer is used to autocorrelate the CTR. However, this method requires the contribution of many bunches to build an autocorrelation trace. The measurement is influenced by the transmission characteristics of the vacuum window and beam splitter. We present here an analysis of materials, as well as possible layouts ...

  10. Effects of stride frequency and foot position at landing on braking force, hip torque, impact peak force and the metabolic cost of running in humans.

    Science.gov (United States)

    Lieberman, Daniel E; Warrener, Anna G; Wang, Justin; Castillo, Eric R

    2015-11-01

    Endurance runners are often advised to use 90 strides min(-1), but how optimal is this stride frequency and why? Endurance runners are also often advised to maintain short strides and avoid landing with the feet too far in front of their hips or knees (colloquially termed 'overstriding'), but how do different kinematic strategies for varying stride length at the same stride frequency affect economy and impact peaks? Linear mixed models were used to analyze repeated measures of stride frequency, the anteroposterior position of the foot at landing, V̇O2 , lower extremity kinematics and vertical ground reaction forces in 14 runners who varied substantially in height and body mass and who were asked to run at 75, 80, 85, 90 and 95 strides min(-1) at 3.0 m s(-1). For every increase of 5 strides min(-1), maximum hip flexor moments in the sagittal plane increased by 5.8% (Pbraking forces were associated with increases in foot landing position relative to the hip (P=0.0005) but not the knee (P=0.54); increases in foot landing position relative to the knee were associated with higher magnitudes (Pbraking forces versus maximum hip flexor moments during swing. The results suggest that runners may benefit from a stride frequency of approximately 85 strides min(-1) and by landing at the end of swing phase with a relatively vertical tibia. © 2015. Published by The Company of Biologists Ltd.

  11. Automated body hair counting and length measurement.

    Science.gov (United States)

    Vallotton, P; Thomas, N

    2008-11-01

    Hair loss or hair excess is a common condition. There is a growing need to quantitatively assess the success of interventions aimed at replenishing areas that lack hair or at removing hair from areas such as the back, the legs, or the arms. Non-invasive methods that do not require staining are highly desirable because the staining process itself may affect the efficacy of the treatment. We introduce a system based on a flatbed scanner and on novel and sensitive image analysis algorithms to count the number of hairs and their individual length. Additionally, a measure of hair visibility is introduced, which allows assessing objectively the severity of the condition. Our system is able to detect even hairs that are difficult to see to a human observer. It is robust to skin impurities or variations in the skin texture and colour. Scanner imaging ensures a sharp image over the whole field. The system analyses on the order of two images per minute, making it suitable for large clinical studies. Counts delivered by a human counter vs. the software were within 10% of each other (N=12). Based on our results, we expect that the software will be useful to a number of researchers investigating medical and cosmetic issues involving objective assessment of pilosity. The algorithm itself may be of use for other applications.

  12. Longitudinal assessment of neuropsychological and temporal/spatial gait characteristics of elderly fallers: taking it all in stride

    Directory of Open Access Journals (Sweden)

    Rebecca K MacAulay

    2015-03-01

    Full Text Available Gait abnormalities are linked to cognitive decline and an increased fall risk within older adults. The present study addressed gaps from cross-sectional studies in the literature by longitudinally examining the interplay between temporal and spatial aspects of gait, cognitive function, age, and lower-extremity strength in elderly fallers and non-fallers. Gait characteristics, neuropsychological and physical test performance were examined at two time points spaced a year apart in cognitively intact individuals aged 60 and older (N = 416. Mixed-model repeated-measure ANCOVAs examined temporal (step time and spatial (stride length gait characteristics during a simple and cognitive-load walking task in fallers as compared to non-fallers. Fallers consistently demonstrated significant alterations in spatial, but not temporal, aspects of gait as compared to non-fallers during both walking tasks. Step time became slower as stride length shortened amongst all participants during the dual task. Shorter strides and slower step times during the dual task were both predicted by worse executive attention/processing speed performance. In summary, divided attention significantly impacts spatial aspects of gait in fallers, suggesting stride length changes may precede declines in other neuropsychological and gait characteristics, thereby selectively increasing fall risk. Our results indicate that multimodal intervention approaches that integrate physical and cognitive remediation strategies may increase the effectiveness of fall risk interventions.

  13. GAIT DYNAMICS, FRACTALS AND FALLS: FINDING MEANING IN THE STRIDE-TO-STRIDE FLUCTUATIONS OF HUMAN WALKING

    Science.gov (United States)

    Hausdorff, Jeffrey M

    2007-01-01

    Until recently, quantitative studies of walking have typically focused on properties of a typical or average stride, ignoring the stride-to-stride fluctuations and considering these fluctuations to be noise. Work over the past two decades has demonstrated, however, that the alleged noise actually conveys important information. The magnitude of the stride-to-stride fluctuations and their changes over time during a walk – gait dynamics – may be useful in understanding the physiology of gait, in quantifying age-related and pathologic alterations in the locomotor control system, and in augmenting objective measurement of mobility and functional status Indeed, alterations in gait dynamics may help to determine disease severity, medication utility, and fall risk, and to objectively document improvements in response to therapeutic interventions, above and beyond what can be gleaned from measures based on the average, typical stride. This review discusses support for the idea that gait dynamics has meaning and may be useful in providing insight into the neural control of locomtion and for enhancing functional assessment of aging, chronic disease, and their impact on mobility. PMID:17618701

  14. Gait dynamics, fractals and falls: finding meaning in the stride-to-stride fluctuations of human walking.

    Science.gov (United States)

    Hausdorff, Jeffrey M

    2007-08-01

    Until recently, quantitative studies of walking have typically focused on properties of a typical or average stride, ignoring the stride-to-stride fluctuations and considering these fluctuations to be noise. Work over the past two decades has demonstrated, however, that the alleged noise actually conveys important information. The magnitude of the stride-to-stride fluctuations and their changes over time during a walk - gait dynamics - may be useful in understanding the physiology of gait, in quantifying age-related and pathologic alterations in the locomotor control system, and in augmenting objective measurement of mobility and functional status. Indeed, alterations in gait dynamics may help to determine disease severity, medication utility, and fall risk, and to objectively document improvements in response to therapeutic interventions, above and beyond what can be gleaned from measures based on the average, typical stride. This review discusses support for the idea that gait dynamics has meaning and may be useful in providing insight into the neural control of locomotion and for enhancing functional assessment of aging, chronic disease, and their impact on mobility.

  15. Automated path length and M56 measurements at Jefferson Lab

    International Nuclear Information System (INIS)

    Hardy, D.; Tang, J.; Legg, R.

    1997-01-01

    Accurate measurement of path length and path length changes versus momentum (M 56 ) are critical for maintaining minimum beam energy spread in the CEBAF (Continuous Electron Beam Accelerator Facility) accelerator at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). The relative path length for each circuit of the beam (1256m) must be equal within 1.5 degrees of 1497 MHz RF phase. A relative path length measurement is made by measuring the relative phases of RF signals from a cavity that is separately excited for each pass of a 4.2 μs pulsed beam. This method distinguishes the path length to less than 0.5 path length error. The development of a VME based automated measurement system for path length and M 56 has contributed to faster machine setup time and has the potential for use as a feedback parameter for automated control

  16. Validation of Navigation Ultrasound for Clavicular Length Measurement

    DEFF Research Database (Denmark)

    Høj, Anders Thorsmark; Villa, Chiara; Christensen, Ole M

    2017-01-01

    ultrasound, to deliver accurate measurements seems promising. To examine the reliability and validity of navigation ultrasound for length measurements of the clavicle, a study was performed using length measurements performed before forensic autopsies from 2012 to 2013. In total, 38 bodies with a median age...

  17. Cervical length measurement: comparison of transabdominal and transvaginal approach

    DEFF Research Database (Denmark)

    Westerway, Sue C; Pedersen, Lars Henning; Hyett, Jon

    2015-01-01

    plots showed an inverse trend with shorter cervixes. In women with a cervix TV scan measurement, TA overestimated cervical length by 12 mm (P ... accurately, particularly if the cervix is short. At 24–34 weeks, a policy of proceeding to TV scan if TA measurement is women attending with symptoms and signs......Objective: To compare transabdominal (TA) and transvaginal (TV) ultrasound assessment of cervical length at 16-41 weeks gestation. Methods: TA and TV ultrasound measurements of cervical length were made on 491 pregnancies of 16-41 weeks gestation. Cervical length was measured from internal...

  18. Tropicalized Lambda Lengths, Measured Laminations and Convexity

    DEFF Research Database (Denmark)

    C. Penner, R.

    of the basic cell decomposition of Riemann's moduli space to other contexts for general moduli spaces of flat connections on a surface. In any case, this discussion drastically simplifies aspects of previous related studies as is explained. Furthermore, a new class of measured laminations relative to an ideal...

  19. Bunch length measurement using coherent Cherenkov radiation

    International Nuclear Information System (INIS)

    Kan, K.; Yang, J.; Ogata, A.; Kondoh, T.; Norizawa, K.; Yoshida, Y.

    2011-01-01

    A new method for bunch diagnostic based on multimode Coherent Cherenkov Radiation (CCR) was proposed. Generation of quasi-monochromatic terahertz (THz) using multimode CCR on the order of 0.1 THz was carried out. The intensity and frequency of CCR were measured directly by a Michelson interferometer and a bolometer. (author)

  20. Real-time single-shot electron bunch length measurements

    CERN Document Server

    Wilke, I; Gillespie, W A; Berden, G; Knippels, G M H; Meer, A F G

    2002-01-01

    Linear accelerators employed as drivers for X-ray free electron lasers (FELs) require relativistic electron bunch with sub-picosecond bunch length. Precise bunch length measurements are important for the tuning and operation of the FELs. Previously, we have demonstrated that electro-optic detection is a powerful technique for sub-picosecond electron bunch length measurements. In those experiments, the measured bunch length was the average of all electron bunches within a macropulse. Here, for the first time, we present the measurement of the length of individual electron bunches using a development of our previous technique. In this experiment, the longitudinal electron bunch shape is encoded electro-optically on to the frequency spectrum of a chirped laser pulse. Subsequently, the laser pulse is dispersed by a grating and the spectrum is imaged with a CCD camera. Single bunch measurements are achieved by using a nanosecond gated camera, and synchronizing the gate with both the electron bunch and the laser pu...

  1. From Concrete to Abstract in the Measurement of Length

    International Nuclear Information System (INIS)

    Stephanou, Andreas; Fisher, William P Jr

    2013-01-01

    The concatenation of units of length is widely viewed as the paradigmatic expression of fundamental measurement. Survey, assessment, and test scores in educational and psychological measurement are often interpreted in ways that assume a concatenation of units to have been established, even though these assumptions are rarely stated or tested. A concatenation model for measurement is shown to be equivalent to a Rasch model: any two units of measurement placed end to end must together be of the same length as either one of them added to itself. This additive principle and a concatenation model of measurement together serve as a heuristic guide for organizing two experimental approaches to calibrating instruments for measuring length. The capacity to reproduce the unit of measurement from theory with no need for repeated empirical calibration experiments, as in the geometrical bisection of the line and the resultant halving of the length measure, is highlighted as essential to demonstrating a thorough understanding of the construct

  2. Bunch length measurements in the SLC damping ring

    International Nuclear Information System (INIS)

    Decker, F.J.; Limberg, T.; Minty, M.; Ross, M.

    1993-05-01

    The synchrotron light of the SLC damping ring was used to measure the bunch length with a streak camera at different times in the damping cycle. There are bunch length oscillations after injection, different equilibrium length during the cycle due to rf manipulations to avoid microwave instability oscillations, and just before extraction there is a longitudinal phase space rotation (bunch muncher) to shorten the bunch length. Measurements under these different conditions are presented and compared with BPM pulse height signals. Calibration and adjustment issues and the connection of the streak camera to the SLC control system are also discussed

  3. Validation of a novel ultrasound measurement of achilles tendon length

    DEFF Research Database (Denmark)

    Barfod, Kristoffer Weisskirchner; Riecke, Anja Falk; Boesen, Anders

    2014-01-01

    PURPOSE: A clinically applicable and accurate method for measuring Achilles tendon length is needed to investigate the influence of elongation of the Achilles tendon after acute rupture. The purpose of this study was to develop and validate an ultrasonographic (US) length measurement...... of the Achilles tendon-aponeurosis complex. METHODS: Both legs of 19 non-injured subjects were examined by magnetic resonance imaging (MRI) and US. The length from calcaneus to the medial head of m. Gastrocnemius was measured by three independent US examiners. Repeated US measurements were performed and compared...... to be further assessed in the setting of acute Achilles tendon rupture. CLINICAL RELEVANCE: This new ultrasound measurement might allow for length measurement of ruptured Achilles tendons in the acute and chronic state after rupture. LEVEL OF EVIDENCE: II....

  4. Analysis and Classification of Stride Patterns Associated with Children Development Using Gait Signal Dynamics Parameters and Ensemble Learning Algorithms

    Directory of Open Access Journals (Sweden)

    Meihong Wu

    2016-01-01

    Full Text Available Measuring stride variability and dynamics in children is useful for the quantitative study of gait maturation and neuromotor development in childhood and adolescence. In this paper, we computed the sample entropy (SampEn and average stride interval (ASI parameters to quantify the stride series of 50 gender-matched children participants in three age groups. We also normalized the SampEn and ASI values by leg length and body mass for each participant, respectively. Results show that the original and normalized SampEn values consistently decrease over the significance level of the Mann-Whitney U test (p<0.01 in children of 3–14 years old, which indicates the stride irregularity has been significantly ameliorated with the body growth. The original and normalized ASI values are also significantly changing when comparing between any two groups of young (aged 3–5 years, middle (aged 6–8 years, and elder (aged 10–14 years children. Such results suggest that healthy children may better modulate their gait cadence rhythm with the development of their musculoskeletal and neurological systems. In addition, the AdaBoost.M2 and Bagging algorithms were used to effectively distinguish the children’s gait patterns. These ensemble learning algorithms both provided excellent gait classification results in terms of overall accuracy (≥90%, recall (≥0.8, and precision (≥0.8077.

  5. Validity of plant fiber length measurement : a review of fiber length measurement based on kenaf as a model

    Science.gov (United States)

    James S. Han; Theodore. Mianowski; Yi-yu. Lin

    1999-01-01

    The efficacy of fiber length measurement techniques such as digitizing, the Kajaani procedure, and NIH Image are compared in order to determine the optimal tool. Kenaf bast fibers, aspen, and red pine fibers were collected from different anatomical parts, and the fiber lengths were compared using various analytical tools. A statistical analysis on the validity of the...

  6. [Comparison between the tooth length measured by cone-beam CT and the tooth length measured with vernier caliper].

    Science.gov (United States)

    Yang, Yi-qiang; Mi, Zhen-lin; Ge, Zhen-lin

    2013-11-01

    To evaluate the accuracy of cone-bean CT (CBCT) on the measurement of the tooth length. One hundred and sixty single root premolars extracted for orthodontic purposes were selected. The tooth length was measured with vernier caliper. The premolars were divided into 10 groups randomly, 16 premolars in each group.In each group, the teeth were lined in molar area, premolar area, canine area and anterior tooth area in maxilla and mandible. Then CBCT was taken, and the tooth length was measured using the software supplied by the manufacturer in coronal and sagittal plane. Accuracy was compared between vernier caliper measurement and CBCT measurement. The tooth length measured by CBCT was smaller than that measured with the vernier caliper. Significant differences were found in six areas, except the maxillary and mandibular premolar areas. With the increase of mesial-distal inclination or buccolingual torque angle, the difference between tooth length measured by CBCT and that measured with vernier caliper increased. The correlation between buccolingual torque angle (∠X1) and the coronal view of CBCT radiology tooth length (Spearmen index was 7.00, P caliper.

  7. Measurement of endodontic file lengths: calibrated versus uncalibrated digital images.

    Science.gov (United States)

    Loushine, R J; Weller, R N; Kimbrough, W F; Potter, B J

    2001-12-01

    This in vitro study compared the accuracy of file length measurements made on calibrated and uncalibrated direct digital images. Endodontic files of known lengths and ISO sizes were used in 10 single-rooted, relatively straight teeth within cadaver specimens. The crowns of the teeth were ground flat and an orthodontic wire of known length was secured to the coronal surface. This wire was placed mesiodistally and perpendicular to the root and served as the reference point for the file measurement and as a calibration reference length. A #20 file was hand-measured to a length that reached the apical third of each tooth. It was inserted and a radiographic image was secured. The instrument was remeasured three additional times at different lengths on the same tooth and reinserted before each image acquisition. Thus 40 digital images were acquired using a GE X-ray unit and a Schick Computed Dental Radiography (CDR) #2 sensor. These images were placed in random order, and an independent, blinded investigator determined the file lengths using on-screen calibrated and uncalibrated measurement of the CDR image with a straight-line and multiple-line measuring technique. The experimental measurements were compared with each other and with the known clinical measurements. A two-way analysis of variance indicated that there was a statistically significant difference showing that the calibrated measurements were more accurate than the uncalibrated measurements (p = 0.0001), and there was no significant difference between the straight-line and multiple-line measuring techniques (p = 0.14).

  8. Head and Tibial Acceleration as a Function of Stride Frequency and Visual Feedback during Running.

    Science.gov (United States)

    Busa, Michael A; Lim, Jongil; van Emmerik, Richard E A; Hamill, Joseph

    2016-01-01

    Individuals regulate the transmission of shock to the head during running at different stride frequencies although the consequences of this on head-gaze stability remain unclear. The purpose of this study was to examine if providing individuals with visual feedback of their head-gaze orientation impacts tibial and head accelerations, shock attenuation and head-gaze motion during preferred speed running at different stride frequencies. Fifteen strides from twelve recreational runners running on a treadmill at their preferred speed were collected during five stride frequencies (preferred, ±10% and ±20% of preferred) in two visual task conditions (with and without real-time visual feedback of head-gaze orientation). The main outcome measures were tibial and head peak accelerations assessed in the time and frequency domains, shock attenuation from tibia to head, and the magnitude and velocity of head-gaze motion. Decreasing stride frequency resulted in greater vertical accelerations of the tibia (pacceleration was only observed for the slowest stride frequency condition. Visual feedback resulted in reduced head acceleration magnitude (pacceleration within a wide range of stride frequencies; only at a stride frequency 20% below preferred did head acceleration increase. Furthermore, impact accelerations of the head and tibia appear to be solely a function of stride frequency as no differences were observed between feedback conditions. Increased visual task demands through head gaze feedback resulted in reductions in head accelerations in the active portion of stance and increased head-gaze stability.

  9. In vivo myograph measurement of muscle contraction at optimal length

    Directory of Open Access Journals (Sweden)

    Ahmed Aminul

    2007-01-01

    Full Text Available Abstract Background Current devices for measuring muscle contraction in vivo have limited accuracy in establishing and re-establishing the optimum muscle length. They are variable in the reproducibility to determine the muscle contraction at this length, and often do not maintain precise conditions during the examination. Consequently, for clinical testing only semi-quantitative methods have been used. Methods We present a newly developed myograph, an accurate measuring device for muscle contraction, consisting of three elements. Firstly, an element for adjusting the axle of the device and the physiological axis of muscle contraction; secondly, an element to accurately position and reposition the extremity of the muscle; and thirdly, an element for the progressive pre-stretching and isometric locking of the target muscle. Thus it is possible to examine individual in vivo muscles in every pre-stretched, specified position, to maintain constant muscle-length conditions, and to accurately re-establish the conditions of the measurement process at later sessions. Results In a sequence of experiments the force of contraction of the muscle at differing stretching lengths were recorded and the forces determined. The optimum muscle length for maximal force of contraction was established. In a following sequence of experiments with smaller graduations around this optimal stretching length an increasingly accurate optimum muscle length for maximal force of contraction was determined. This optimum length was also accurately re-established at later sessions. Conclusion We have introduced a new technical solution for valid, reproducible in vivo force measurements on every possible point of the stretching curve. Thus it should be possible to study the muscle contraction in vivo to the same level of accuracy as is achieved in tests with in vitro organ preparations.

  10. The impact of precise robotic lesion length measurement on stent length selection: ramifications for stent savings.

    Science.gov (United States)

    Campbell, Paul T; Kruse, Kevin R; Kroll, Christopher R; Patterson, Janet Y; Esposito, Michele J

    2015-09-01

    Coronary stent deployment outcomes can be negatively impacted by inaccurate lesion measurement and inappropriate stent length selection (SLS). We compared visual estimate of these parameters to those provided by the CorPath 200® Robotic PCI System. Sixty consecutive patients who underwent coronary stent placement utilizing the CorPath System were evaluated. The treating physician assessed orthogonal images and provided visual estimates of lesion length and SLS. The robotic system was then used for the same measures. SLS was considered to be accurate when visual estimate and robotic measures were in agreement. Visual estimate SLSs were considered to be "short" or "long" if they were below or above the robotic-selected stents, respectively. Only 35% (21/60) of visually estimated lesions resulted in accurate SLS, whereas 33% (20/60) and 32% (19/60) of the visually estimated SLSs were long and short, respectively. In 5 cases (8.3%), 1 less stent was placed based on the robotic lesion measurement being shorter than the visual estimate. Visual estimate assessment of lesion length and SLS is highly variable with 65% of the cases being inaccurately measured when compared to objective measures obtained from the robotic system. The 32% of the cases where lesions were visually estimated to be short represents cases that often require the use of extra stents after the full lesion is not covered by 1 stent [longitudinal geographic miss (LGM)]. Further, these data showed that the use of the robotic system prevented the use of extra stents in 8.3% of the cases. Measurement of lesions with robotic PCI may reduce measurement errors, need for extra stents, and LGM. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Precision and accuracy of the new XPrecia Stride mobile coagulometer.

    Science.gov (United States)

    Piacenza, Francesco; Galeazzi, Roberta; Cardelli, Maurizio; Moroni, Fausto; Provinciali, Mauro; Pierpaoli, Elisa; Giovagnetti, Simona; Appolloni, Stefania; Marchegiani, Francesca

    2017-08-01

    Oral anticoagulation therapy (OAT) with coumarins (vitamin K antagonist) is the most used against thromboembolism. Prothrombin time (PT) International Normalized Ratio (INR) monitoring is fundamental to establish coumarins dosage and prevent bleeding complications or thrombotic events. In this contest, the method and apparatus used for providing the INR measurements are crucial. Several studies have been published regarding the precision and accuracy of mobile coagulometers with different conclusions. No studies have been published regarding the new XPrecia Stride Mobile Coagulometer (Siemens). The aim of this work is to analyze precision and accuracy of the new XPrecia Stride mobile coagulometer to provide recommendations for clinical use and quality control. A total of 163 patients (mean age=77.4years old) under Warfarin OAT for whom the INR was assessed by both the traditional cs 2100i Sysmex and the new Xprecia Stride Mobile Coagulometer were included in this pilot study. The precision of the new mobile coagulometer resulted very good (CV15% from the true value in 20% of cases). Considering the overall results obtained by the new Xprecia Stride in comparison to that ones obtained from the other commercial devices, we can conclude that the new coagulometer is enough reliable for clinical settings. However, a larger trial to confirm these data is needed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Sonographic Measurement of Normal Splenic Length in Korean Adults

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Sang Bum; Cheon, Byung Kook; Kim, Jong Min; Oh, Kyung Seoung; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk [Kosin University College of Medicine, Busan (Korea, Republic of)

    1996-12-15

    To establish upper limit of normal splenic length of Korean adults on ultrasonography and to determice the degree of interobserver and intraobserver variation. Ultrasonographic scans were performed to measure the maximum length of spleen in 105 of 150 adults selected by convenience sampling. Remained 45 cases with any conditions that could alter splenic size were excluded from this study. The maximum length of spleen was measured and correlated with body surface area, patient height, weight, age and sex. In 31 of the 105 adults we evaluated the interobserver and intraobserver variations in sonographic measurements of splenic length obtained by three radiologists in blind fashion. The mean splenic length in 105 adults was 8.56cm ({+-} 0.95). The splenic length positively correlated with body surface area, patient height and weight (P <0.001), and negatively correlated with patient age (P < 0.01). Male spleen (8.87 cm {+-} 1.07) was longer than female spleen (8.35 cm {+-} 0.81) (P < 0.05). The following guidelines are proposed for the upper limit of normal splenic length at different groups of body surface area: no longer than 10 cm at 1.20{approx}1.59 m{sup 2}, 11 cm at1.60{approx}1.79 m{sup 2}, and 12 cm at 1.80{approx}1.99 m{sup 2}. The mean interobserver variation between any two radiologists ranged from 0.32 cm ({+-} 0.29) to 0.39 cm ({+-} 0.33) and interobserver variations were within 1 cm in 96%. The mean intraobserver variations were within 0.5 cm in 91%. The splenic length closely correlated with body surface area, patient height, weight and age. Particularly the upper limit of normal splenic length changed according to body surface area. Interobserver variation about 1 cm and intraobserver variation about 0.5 cm should be considered in the measurement of the splenic length on ultrasonography

  13. Extraction of stride events from gait accelerometry during treadmill walking.

    Science.gov (United States)

    Sejdić, Ervin; Lowry, Kristin A; Bellanca, Jennica; Perera, Subashan; Redfern, Mark S; Brach, Jennifer S

    Evaluating stride events can be valuable for understanding the changes in walking due to aging and neurological diseases. However, creating the time series necessary for this analysis can be cumbersome. In particular, finding heel contact and toe-off events which define the gait cycles accurately are difficult. We proposed a method to extract stride cycle events from tri-axial accelerometry signals. We validated our method via data collected from 14 healthy controls, 10 participants with Parkinson's disease and 11 participants with peripheral neuropathy. All participants walked at self-selected comfortable and reduced speeds on a computer-controlled treadmill. Gait accelerometry signals were captured via a tri-axial accelerometer positioned over the L3 segment of the lumbar spine. Motion capture data were also collected and served as the comparison method. Our analysis of the accelerometry data showed that the proposed methodology was able to accurately extract heel and toe contact events from both feet. We used t-tests, ANOVA and mixed models to summarize results and make comparisons. Mean gait cycle intervals were the same as those derived from motion capture and cycle-to-cycle variability measures were within 1.5%. Subject group differences could be identified similarly using measures with the two methods. A simple tri-axial acceleromter accompanied by a signal processing algorithm can be used to capture stride events. Clinical Impact: The proposed algorithm enables the assessment of stride events during treadmill walking, and is the first step towards the assessment of stride events using tri-axial accelerometers in real-life settings.

  14. Electron bunch length measurement with a wakefield radiation decelerator

    Directory of Open Access Journals (Sweden)

    Weiwei Li

    2014-03-01

    Full Text Available In this paper, we propose a novel method to measure the electron bunch length with a dielectric wakefield radiation (DWR decelerator which is composed of two dielectric-lined waveguides (DLWs and an electron spectrometer. When an electron beam passes through a DLW, the DWR is excited which leads to an energy loss of the electron beam. The energy loss is found to be largely dependent on the electron bunch length and can be easily measured by an electron spectrometer which is essential for a normal accelerator facility. Our study shows that this method has a high resolution and a great simplicity.

  15. Measurement of the diffusion length of thermal neutrons inside graphite

    International Nuclear Information System (INIS)

    Ertaud, A.; Beauge, R.; Fauquez, H.; De Laboulay, H.; Mercier, C.; Vautrey, L.

    1948-11-01

    The diffusion length of thermal neutrons inside a given industrial graphite is determined by measuring the neutron density inside a parallelepipedal piling up of graphite bricks (2.10 x 2.10 x 2.442 m). A 3.8 curies (Ra α → Be) source is placed inside the parallelepipedal block of graphite and thin manganese detectors are used. Corrections are added to the unweighted measurements to take into account the effects of the damping of supra-thermal neutrons in the measurement area. These corrections are experimentally deduced from the differential measurements made with a cadmium screen interposed between the source and the first plane of measurement. An error analysis completes the report. The diffusion length obtained is: L = 45.7 cm ± 0.3. The average density of the graphite used is 1.76 and the average apparent density of the piling up is 1.71. (J.S.)

  16. Measuring Clearance Mechanics Based on Dynamic Leg Length

    Science.gov (United States)

    Khamis, Sam; Danino, Barry; Hayek, Shlomo; Carmeli, Eli

    2018-01-01

    The aim of this study was to quantify clearance mechanics during gait. Seventeen children diagnosed with hemiplegic cerebral palsy underwent a three-dimensional gait analysis evaluation. Dynamic leg lengths were measured from the hip joint center to the heel, to the ankle joint center and to the forefoot throughout the gait cycle. Significant…

  17. Measurement of surface crack length using image processing technology

    International Nuclear Information System (INIS)

    Nahm, Seung Hoon; Kim, Si Cheon; Kim, Yong Il; Ryu, Dae Hyun

    2001-01-01

    The development of a new experimental method is required to easily observe the growth behavior of fatigue cracks. To satisfy the requirement, an image processing technique was introduced to fatigue testing. The length of surface fatigue crack could be successfully measured by the image processing system. At first, the image data of cracks were stored into the computer while the cyclic loading was interrupted. After testing, crack length was determined using image processing software which was developed by ourselves. Block matching method was applied to the detection of surface fatigue cracks. By comparing the data measured by image processing system with the data measured by manual measurement with a microscope, the effectiveness of the image processing system was established. If the proposed method is used to monitor and observe the crack growth behavior automatically, the time and efforts for fatigue test could be dramatically reduced

  18. Electron Bunch Length Measurement for LCLS at SLAC

    International Nuclear Information System (INIS)

    Zelazny, M.; Allison, S.; Chevtsov, Sergei; Emma, P.; Kotturi, K.d.; Loos, H.; Peng, S.; Rogind, D.; Straumann, T.

    2007-01-01

    At Stanford Linear Accelerator Center (SLAC) a Bunch Length Measurement system has been developed to measure the length of the electron bunch for its new Linac Coherent Light Source (LCLS). This destructive measurement uses a transverse-mounted RF deflector (TCAV) to vertically streak the electron beam and an image taken with an insertable screen and a camera. The device control software was implemented with the Experimental Physics and Industrial Control System (EPICS) toolkit. The analysis software was implemented in Matlab(trademark) using the EPICS/Channel Access Interface for Scilab(trademark) and Matlab(trademark) (labCA). This architecture allowed engineers and physicists to develop and integrate their control and analysis without duplication of effort

  19. Electron Bunch Length Measurement for LCLS at SLAC

    Energy Technology Data Exchange (ETDEWEB)

    Zelazny, M.; Allison, S.; Chevtsov, Sergei; Emma, P.; Kotturi, K.d.; Loos, H.; Peng, S.; Rogind, D.; Straumann, T.; /SLAC

    2007-10-04

    At Stanford Linear Accelerator Center (SLAC) a Bunch Length Measurement system has been developed to measure the length of the electron bunch for its new Linac Coherent Light Source (LCLS). This destructive measurement uses a transverse-mounted RF deflector (TCAV) to vertically streak the electron beam and an image taken with an insertable screen and a camera. The device control software was implemented with the Experimental Physics and Industrial Control System (EPICS) toolkit. The analysis software was implemented in Matlab{trademark} using the EPICS/Channel Access Interface for Scilab{trademark} and Matlab{trademark} (labCA). This architecture allowed engineers and physicists to develop and integrate their control and analysis without duplication of effort.

  20. Stride length asymmetry in split-belt locomotion

    NARCIS (Netherlands)

    Hoogkamer, W.; Bruijn, S.M.; Duysens, J.

    2013-01-01

    The number of studies utilizing a split-belt treadmill is rapidly increasing in recent years. This has led to some confusion regarding the definitions of reported gait parameters. The purpose of this paper is to clearly present the definitions of the gait parameters that are commonly used in

  1. Absolute bunch length measurements by incoherent radiation fluctuation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sannibale, Fernando; Stupakov, Gennady; Zolotorev, Max; Filippetto, Daniele; Jagerhofer, Lukas

    2008-09-29

    By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and successfully tested a simple scheme based on this principle that allows for the absolute measurement of the rms bunch length. A description of the method and the experimental results are presented.

  2. Absolute Bunch Length Measurements by Incoherent Radiation Fluctuation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sannibale, F.; /LBL, Berkeley; Stupakov, G.V.; /SLAC; Zolotorev, M.S.; /LBL, Berkeley; Filippetto, D.; /INFN, Rome; Jagerhofer, L.; /Vienna, Tech. U.

    2009-12-09

    By analyzing the pulse to pulse intensity fluctuations of the radiation emitted by a charge particle in the incoherent part of the spectrum, it is possible to extract information about the spatial distribution of the beam. At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory, we have developed and successfully tested a simple scheme based on this principle that allows for the absolute measurement of the rms bunch length. A description of the method and the experimental results are presented.

  3. Electron bunch length measurement at the Vanderbilt FEL

    Energy Technology Data Exchange (ETDEWEB)

    Amirmadhi, F.; Brau, C.A.; Mendenhall, M. [Vanderbilt Free-Electron-Laser Center, Nashville, TN (United States)] [and others

    1995-12-31

    During the past few years, a number of experiments have been performed to demonstrate the possibility to extract the longitudinal charge distribution from spectroscopic measurements of the coherent far-infrared radiation emitted as transition radiation or synchrotron radiation. Coherent emission occurs in a spectral region where the wavelength is comparable to or longer than the bunch length, leading to an enhancement of the radiation intensity that is on the order of the number of particles per bunch, as compared to incoherent radiation. This technique is particularly useful in the region of mm and sub-mm bunch lengths, a range where streak-cameras cannot be used for beam diagnostics due to their limited time resolution. Here we report on experiments that go beyond the proof of principle of this technique by applying it to the study and optimization of FEL performance. We investigated the longitudinal bunch length of the Vanderbilt FEL by analyzing the spectrum of coherent transition radiation emitted by the electron bunches. By monitoring the bunch length while applying a bunch-compression technique, the amount of the compression could be easily observed. This enabled us to perform a systematic study of the FEL performance, especially gain and optical pulse width, as a function of the longitudinal electron distribution in the bunch. The results of this study will be presented and discussed.

  4. Adaptation and prosthesis effects on stride-to-stride fluctuations in amputee gait.

    Directory of Open Access Journals (Sweden)

    Shane R Wurdeman

    Full Text Available Twenty-four individuals with transtibial amputation were recruited to a randomized, crossover design study to examine stride-to-stride fluctuations of lower limb joint flexion/extension time series using the largest Lyapunov exponent (λ. Each individual wore a "more appropriate" and a "less appropriate" prosthesis design based on the subject's previous functional classification for a three week adaptation period. Results showed decreased λ for the sound ankle compared to the prosthetic ankle (F1,23 = 13.897, p = 0.001 and a decreased λ for the "more appropriate" prosthesis (F1,23 = 4.849, p = 0.038. There was also a significant effect for the time point in the adaptation period (F2,46 = 3.164, p = 0.050. Through the adaptation period, a freezing and subsequent freeing of dynamic degrees of freedom was seen as the λ at the ankle decreased at the midpoint of the adaptation period compared to the initial prosthesis fitting (p = 0.032, but then increased at the end compared to the midpoint (p = 0.042. No differences were seen between the initial fitting and the end of the adaptation for λ (p = 0.577. It is concluded that the λ may be a feasible clinical tool for measuring prosthesis functionality and adaptation to a new prosthesis is a process through which the motor control develops mastery of redundant degrees of freedom present in the system.

  5. Investigating the correlation between paediatric stride interval persistence and gross energy expenditure

    Directory of Open Access Journals (Sweden)

    Sejdić Ervin

    2010-02-01

    Full Text Available Abstract Background Stride interval persistence, a term used to describe the correlation structure of stride interval time series, is thought to provide insight into neuromotor control, though its exact clinical meaning has not yet been realized. Since human locomotion is shaped by energy efficient movements, it has been hypothesized that stride interval dynamics and energy expenditure may be inherently tied, both having demonstrated similar sensitivities to age, disease, and pace-constrained walking. Findings This study tested for correlations between stride interval persistence and measures of energy expenditure including mass-specific gross oxygen consumption per minute (, mass-specific gross oxygen cost per meter (VO2 and heart rate (HR. Metabolic and stride interval data were collected from 30 asymptomatic children who completed one 10-minute walking trial under each of the following conditions: (i overground walking, (ii hands-free treadmill walking, and (iii handrail-supported treadmill walking. Stride interval persistence was not significantly correlated with (p > 0.32, VO2 (p > 0.18 or HR (p > 0.56. Conclusions No simple linear dependence exists between stride interval persistence and measures of gross energy expenditure in asymptomatic children when walking overground and on a treadmill.

  6. Constant-Length Random Substitutions and Gibbs Measures

    Science.gov (United States)

    Maldonado, C.; Trejo-Valencia, L.; Ugalde, E.

    2018-04-01

    This work is devoted to the study of processes generated by random substitutions over a finite alphabet. We prove, under mild conditions on the substitution's rule, the existence of a unique process which remains invariant under the substitution, and which exhibits a polynomial decay of correlations. For constant-length substitutions, we go further by proving that the invariant state is precisely a Gibbs measure which can be obtained as the projective limit of its natural Markovian approximations. We end up the paper by studying a class of substitutions whose invariant state is the unique Gibbs measure for a hierarchical two-body interaction.

  7. The elementary school teachers’ ability in the length measurement

    Science.gov (United States)

    Julie, Hongki

    2017-09-01

    The purpose of this study was to describe the elementary school teachers' mathematical ability (1) to develop students’ activities which constructed longer than, shorter than, and as long as concepts, (2) to develop students’ activities which constructed standard unit on the length measurement, and (3) to develop a problem which used by student to construct why a conversion activity on the unit of the length was useful in the daily life after they have participated in the Realistic Mathematics Education (RME) workshops. Curry and Outhread said if teachers knew more about the growth of students’ conceptual understanding of the length, they would be better able to teach that topic [4]. Therefore, in the workshop, teachers were asked to learn more on the stages of the measurement teaching and learning process and why each stage was important. This capability was described by the results of a test which was content of four problems given to teachers after they have attended the workshop. Research subjects in this study were 14 elementary school teachers at Yogyakarta. The results of the study were as follows: (1) only four of 14 teachers who had the first ability; (2) all teachers had the second ability; and (3) all the teachers did not have the third ability.

  8. π K atom lifetime and π K scattering length measurements

    Science.gov (United States)

    Yazkov, V.; DIRAC Collaboration

    2015-03-01

    Theory, using Low Energy QCD, calculated with high precision the π π and π K scattering length. To check the theoretical calculations for the processes, including s-quarks, we must measure the π K atom lifetime, that is connected to the π K scattering lengths by a precise relation. Evidence for π K atoms production is reported on a base of a number of produced π K atoms found to be N A = 653±42 together with the value of the π K pairs from atoms that breakup in the same target n A = 178±49. Using these results the analysis yields to a first value for the π K atom lifetime of τ = 2.5^{+3.0}_{-1.8} fs and a first model-independent measurement of the S-wave isospin-odd π K scattering length |a-0| = 1/3 |a^{1/2}0 - a^{3/2}0| = 0.11^{+0.09}_{-0.04} M^{-1}_{π } (the I and L in {aIL} stands for isospin and orbital momentum).

  9. Length-free near infrared measurement of newborn malnutrition

    Science.gov (United States)

    Mustafa, Fatin Hamimi; Bek, Emily J.; Huvanandana, Jacqueline; Jones, Peter W.; Carberry, Angela E.; Jeffery, Heather E.; Jin, Craig T.; McEwan, Alistair L.

    2016-11-01

    Under-nutrition in neonates can cause immediate mortality, impaired cognitive development and early onset adult disease. Body fat percentage measured using air-displacement-plethysmography has been found to better indicate under-nutrition than conventional birth weight percentiles. However, air-displacement-plethysmography equipment is expensive and non-portable, so is not suited for use in developing communities where the burden is often the greatest. We proposed a new body fat measurement technique using a length-free model with near-infrared spectroscopy measurements on a single site of the body - the thigh. To remove the need for length measurement, we developed a model with five discrete wavelengths and a sex parameter. The model was developed using air-displacement-plethysmography measurements in 52 neonates within 48 hours of birth. We identified instrumentation required in a low-cost LED-based screening device and incorporated a receptor device that can increase the amount of light collected. This near-infrared method may be suitable as a low cost screening tool for detecting body fat levels and monitoring nutritional interventions for malnutrition in neonates and young children in resource-constrained communities.

  10. Measurement of neutron diffusion length in heavy concrete

    International Nuclear Information System (INIS)

    Krejci, D.

    2007-04-01

    Using an aluminium sampler filled with heavy concrete the neutron diffusion length was determined, measuring thermal and fast neutrons over the whole beam hole with various threshold detectors using gold samples. These calculations should describe the neutron distribution in the whole concrete shield of the reactor and contribute to the investigation of the activation of the concrete shield using reactor parameters like operating time, power and neutron flux. Instrumentation, activation and positioning of the samples in the beam hole of the TRIGA Mark II reactor are described. (nevyjel)

  11. Altered fractal dynamics of gait: reduced stride-interval correlations with aging and Huntington's disease

    Science.gov (United States)

    Hausdorff, J. M.; Mitchell, S. L.; Firtion, R.; Peng, C. K.; Cudkowicz, M. E.; Wei, J. Y.; Goldberger, A. L.

    1997-01-01

    Fluctuations in the duration of the gait cycle (the stride interval) display fractal dynamics and long-range correlations in healthy young adults. We hypothesized that these stride-interval correlations would be altered by changes in neurological function associated with aging and certain disease states. To test this hypothesis, we compared the stride-interval time series of 1) healthy elderly subjects and young controls and of 2) subjects with Huntington's disease and healthy controls. Using detrended fluctuation analysis we computed alpha, a measure of the degree to which one stride interval is correlated with previous and subsequent intervals over different time scales. The scaling exponent alpha was significantly lower in elderly subjects compared with young subjects (elderly: 0.68 +/- 0.14; young: 0.87 +/- 0.15; P elderly subjects and in subjects with Huntington's disease. Abnormal alterations in the fractal properties of gait dynamics are apparently associated with changes in central nervous system control.

  12. Philtrum length and intercommissural distance measurements at mixed dentition period.

    Science.gov (United States)

    Mostafa, Mostafa; Hassib, Nehal; Sayed, Inas; Neamat, Amany; Ramzy, Magda; El-Badry, Tarek; ElGabry, Hisham; Salem, Haidy; Omar, Nada; Ismail, Amira; Ibrahim, Yousra; Shebaita, Amr; Allam, Ahmed; Mostafa, Magdy

    2018-05-01

    Anthropometric measurements of the lip and mouth are of great importance in clinical dysmorphology as well as reconstructive plastic surgery. In this study, the philtrum length (PhL) and intercommissural distance (ICmD) nomograms for Egyptian children in the mixed dentition period were established. A group of 1,338 Egyptian students in primary schools (735 boys and 603 girls) were included in the study. The students were at mixed dentition period and their ages ranged from 7 to 12 years. Anthropometric norms of PhL and ICmD were developed with significant sex difference in certain groups. A ratio between PhL and ICmD was developed. These data will help facilitate both objective and subjective evaluation of the lip and mouth for proper diagnosis of orofacial anomalies and variations as well as for ideal treatment plans. © 2018 Wiley Periodicals, Inc.

  13. Measuring (subglacial bedform orientation, length, and longitudinal asymmetry - Method assessment.

    Directory of Open Access Journals (Sweden)

    Marco G Jorge

    Full Text Available Geospatial analysis software provides a range of tools that can be used to measure landform morphometry. Often, a metric can be computed with different techniques that may give different results. This study is an assessment of 5 different methods for measuring longitudinal, or streamlined, subglacial bedform morphometry: orientation, length and longitudinal asymmetry, all of which require defining a longitudinal axis. The methods use the standard deviational ellipse (not previously applied in this context, the longest straight line fitting inside the bedform footprint (2 approaches, the minimum-size footprint-bounding rectangle, and Euler's approximation. We assess how well these methods replicate morphometric data derived from a manually mapped (visually interpreted longitudinal axis, which, though subjective, is the most typically used reference. A dataset of 100 subglacial bedforms covering the size and shape range of those in the Puget Lowland, Washington, USA is used. For bedforms with elongation > 5, deviations from the reference values are negligible for all methods but Euler's approximation (length. For bedforms with elongation < 5, most methods had small mean absolute error (MAE and median absolute deviation (MAD for all morphometrics and thus can be confidently used to characterize the central tendencies of their distributions. However, some methods are better than others. The least precise methods are the ones based on the longest straight line and Euler's approximation; using these for statistical dispersion analysis is discouraged. Because the standard deviational ellipse method is relatively shape invariant and closely replicates the reference values, it is the recommended method. Speculatively, this study may also apply to negative-relief, and fluvial and aeolian bedforms.

  14. Automated stride assistance device improved the gait parameters and energy cost during walking of healthy middle-aged females but not those of young controls

    Science.gov (United States)

    Otsuki, Risa; Matsumoto, Hiromi; Ueki, Masaru; Uehara, Kazutake; Nozawa, Nobuko; Osaki, Mari; Hagino, Hiroshi

    2016-01-01

    [Purpose] The aim of this study was to clarify the effects of an automated stride assistance device on gait parameters and energy cost during walking performed by healthy middle-aged and young females. [Subjects and Methods] Ten middle-aged females and 10 young females were recruited as case and control participants, respectively. The participants walked for 3 minutes continuously under two different experimental conditions: with the device and without the device. Walking distance, mean walking speed, mean step length, cadence, walk ratio and the physiological cost index during the 3-minutes walk were measured. [Results] When walking with the stride assistance device, the step length and walk ratio of the middle-aged group were significantly higher than without it. Also, during walking without assistance from the device, the physiological cost index of the middle-aged group significantly increased; whereas during walking with assistance, there was no change. The intergroup comparison in the middle-aged group showed the physiological cost index was lower under the experimental condition with assistance provided, as opposed to the condition without the provision of assistance. [Conclusion] The results of this study show that the stride assistance device improved the gait parameters of the middle-aged group but not those of young controls. PMID:28174452

  15. Increased gait variability may not imply impaired stride-to-stride control of walking in healthy older adults: Winner: 2013 Gait and Clinical Movement Analysis Society Best Paper Award.

    Science.gov (United States)

    Dingwell, Jonathan B; Salinas, Mandy M; Cusumano, Joseph P

    2017-06-01

    Older adults exhibit increased gait variability that is associated with fall history and predicts future falls. It is not known to what extent this increased variability results from increased physiological noise versus a decreased ability to regulate walking movements. To "walk", a person must move a finite distance in finite time, making stride length (L n ) and time (T n ) the fundamental stride variables to define forward walking. Multiple age-related physiological changes increase neuromotor noise, increasing gait variability. If older adults also alter how they regulate their stride variables, this could further exacerbate that variability. We previously developed a Goal Equivalent Manifold (GEM) computational framework specifically to separate these causes of variability. Here, we apply this framework to identify how both young and high-functioning healthy older adults regulate stepping from each stride to the next. Healthy older adults exhibited increased gait variability, independent of walking speed. However, despite this, these healthy older adults also concurrently exhibited no differences (all p>0.50) from young adults either in how their stride variability was distributed relative to the GEM or in how they regulated, from stride to stride, either their basic stepping variables or deviations relative to the GEM. Using a validated computational model, we found these experimental findings were consistent with increased gait variability arising solely from increased neuromotor noise, and not from changes in stride-to-stride control. Thus, age-related increased gait variability likely precedes impaired stepping control. This suggests these changes may in turn precede increased fall risk. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Determination of funnel length from cross section versus LET measurements

    International Nuclear Information System (INIS)

    Golke, K.W.

    1993-01-01

    This paper proposes an empirical model and method for determining the funnel length from heavy ion upset cross section as a function LET data. It is valid for bulk technologies having a lightly doped epi region over a heavily doped substrate region. Definition of the funnel length is necessary in order to define the heavy ion track length along which charge is collected. Knowing the track length and the threshold LET for upset, the critical charge can be calculated. Critical charge as well as sensitive volume dimensions for upset are required input parameters for upset calculation codes such as CREME. The more accurate the critical charge calculation, the more accurate the calculated upset rate

  17. Gait variability and basal ganglia disorders: stride-to-stride variations of gait cycle timing in Parkinson's disease and Huntington's disease

    Science.gov (United States)

    Hausdorff, J. M.; Cudkowicz, M. E.; Firtion, R.; Wei, J. Y.; Goldberger, A. L.

    1998-01-01

    The basal ganglia are thought to play an important role in regulating motor programs involved in gait and in the fluidity and sequencing of movement. We postulated that the ability to maintain a steady gait, with low stride-to-stride variability of gait cycle timing and its subphases, would be diminished with both Parkinson's disease (PD) and Huntington's disease (HD). To test this hypothesis, we obtained quantitative measures of stride-to-stride variability of gait cycle timing in subjects with PD (n = 15), HD (n = 20), and disease-free controls (n = 16). All measures of gait variability were significantly increased in PD and HD. In subjects with PD and HD, gait variability measures were two and three times that observed in control subjects, respectively. The degree of gait variability correlated with disease severity. In contrast, gait speed was significantly lower in PD, but not in HD, and average gait cycle duration and the time spent in many subphases of the gait cycle were similar in control subjects, HD subjects, and PD subjects. These findings are consistent with a differential control of gait variability, speed, and average gait cycle timing that may have implications for understanding the role of the basal ganglia in locomotor control and for quantitatively assessing gait in clinical settings.

  18. Ocular Axial Length Measurement Among Normal Adults Using ...

    African Journals Online (AJOL)

    2017-07-26

    Jul 26, 2017 ... Background/Introduction: Macrophthalmia and microphthalmia are cardinal signs of many orbito-ocular and systemic diseases which are seen in northern Nigeria. Some cases of refractive error may also be directly related to the ocular axial length (AL). The need for an imaging parameter that will aid their ...

  19. Reducing trial length in force platform posturographic sleep deprivation measurements

    Science.gov (United States)

    Forsman, P.; Hæggström, E.; Wallin, A.

    2007-09-01

    Sleepiness correlates with sleep-related accidents, but convenient tests for sleepiness monitoring are scarce. The posturographic test is a method to assess balance, and this paper describes one phase of the development of a posturographic sleepiness monitoring method. We investigated the relationship between trial length and accuracy of the posturographic time-awake (TA) estimate. Twenty-one healthy adults were kept awake for 32 h and their balance was recorded, 16 times with 30 s trials, as a function of TA. The balance was analysed with regards to fractal dimension, most common sway amplitude and time interval for open-loop stance control. While a 30 s trial allows estimating the TA of individual subjects with better than 5 h accuracy, repeating the analysis using shorter trial lengths showed that 18 s sufficed to achieve the targeted 5 h accuracy. Moreover, it was found that with increasing TA, the posturographic parameters estimated the subjects' TA more accurately.

  20. Measurement of electron beam bunch phase length by rectangular cavities

    International Nuclear Information System (INIS)

    Afanas'ev, V.D.; Rudychev, V.G.; Ushakov, V.I.

    1976-01-01

    An analysis of a phase length of electron bunches with the help of crossed rectangular resonators with the Hsub(102) oscillation type has been made. It has been shown that the electron coordinates after the duplex resonator are described by an ellipse equation for a non-modulated beam. An influence of the initial energy spread upon the electron motion has been studied. It has been ascertained that energy modulation of the electron beam results in displacement of each electron with respect to the ellipse which is proportional to modulation energy, i.e. an error in determination of the phase length of an electron bunch is proportional to the beam energy spread. Relations have been obtained which enable to find genuine values of phases of the analyzed electrons with an accuracy up to linear multipliers

  1. Partial body weight support treadmill training speed influences paretic and non-paretic leg muscle activation, stride characteristics, and ratings of perceived exertion during acute stroke rehabilitation.

    Science.gov (United States)

    Burnfield, Judith M; Buster, Thad W; Goldman, Amy J; Corbridge, Laura M; Harper-Hanigan, Kellee

    2016-06-01

    Intensive task-specific training is promoted as one approach for facilitating neural plastic brain changes and associated motor behavior gains following neurologic injury. Partial body weight support treadmill training (PBWSTT), is one task-specific approach frequently used to improve walking during the acute period of stroke recovery (training parameters and physiologic demands during this early recovery phase. To examine the impact of four walking speeds on stride characteristics, lower extremity muscle demands (both paretic and non-paretic), Borg ratings of perceived exertion (RPE), and blood pressure. A prospective, repeated measures design was used. Ten inpatients post unilateral stroke participated. Following three familiarization sessions, participants engaged in PBWSTT at four predetermined speeds (0.5, 1.0, 1.5 and 2.0mph) while bilateral electromyographic and stride characteristic data were recorded. RPE was evaluated immediately following each trial. Stride length, cadence, and paretic single limb support increased with faster walking speeds (p⩽0.001), while non-paretic single limb support remained nearly constant. Faster walking resulted in greater peak and mean muscle activation in the paretic medial hamstrings, vastus lateralis and medial gastrocnemius, and non-paretic medial gastrocnemius (p⩽0.001). RPE also was greatest at the fastest compared to two slowest speeds (ptraining at the slowest speeds. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Dynamic Length Metrology (DLM) for measurements with sub-micrometre uncertainty in a production environment

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Hansen, Hans Nørgaard; Hattel, Jesper Henri

    2016-01-01

    Conventional length metrology for traceable accurate measurements requires costly temperature controlled facilities, long waiting time for part acclimatisation, and separate part material characterisation. This work describes a method called Dynamic Length Metrology (DLM) developed to achieve sub...

  3. Stride time synergy in relation to walking during dual task

    DEFF Research Database (Denmark)

    Læssøe, Uffe; Madeleine, Pascal

    2012-01-01

    with a positive slope going through the mean of the strides, and bad variance with respect to a similar line with a negative slope. The general variance coefficient (CV%) was also computed. The effect of introducing a concurrent cognitive task (dual task: counting backwards in sequences of 7) was evaluated...... point of view elemental and performance variables may represent good and bad components of variability [2]. In this study we propose that the gait pattern can be seen as an on-going movement synergy in which each stride is corrected by the next stride (elemental variables) to ensure a steady gait...... (performance variable). AIM: The aim of this study was to evaluate stride time synergy and to identify good and bad stride variability in relation to walking during dual task. METHODS: Thirteen healthy young participants walked along a 2x5 meter figure-of-eight track at a self-selected comfortable speed...

  4. Statistical length of DNA based on AFM image measured by a computer

    International Nuclear Information System (INIS)

    Chen Xinqing; Qiu Xijun; Zhang Yi; Hu Jun; Wu Shiying; Huang Yibo; Ai Xiaobai; Li Minqian

    2001-01-01

    Taking advantage of image processing technology, the contour length of DNA molecule was measured automatically by a computer. Based on the AFM image of DNA, the topography of DNA was simulated into a curve. Then the DNA length was measured automatically by inserting mode. It was shown that the experimental length of a naturally deposited DNA (180.4 +- 16.4 nm) was well consistent with the theoretical length (185.0 nm). Comparing to other methods, the present approach had advantages of precision and automatism. The stretched DNA was also measured. It present approach had advantages of precision and automatism. The stretched DNA was also measured. It was shown that the experimental length (343.6 +- 20.7 nm) was much longer than the theoretical length (307.0 nm). This result indicated that the stretching process had a distinct effect on the DNA length. However, the method provided here avoided the DNA-stretching effect

  5. An induction sensor for measuring rectilinear movements of substantial length

    International Nuclear Information System (INIS)

    Jaudou, Yves.

    1973-01-01

    The invention is characterized in that it comprises the steps of making one end of a magnetic core integral with the objet, the movements of which are to be measured. The core has the shape of an isoscele prism the base surface of which slides within two aligned coils contained in two adjacent arms of an A-C operated Wheatstone bridge. The impedances in the W-bridge other two arms is adjusted in order that the Wheatstone bridge be balanced at a given position of the object. The movement of the object is measured from the latter given position through the potential difference, proportional to said movement developed between two opposite apices E and D of the bridge, the latter being fed with AC between the other two apices (A and B). This can be applied to the measurement of the movements of irradiation capsules in a nuclear reactor [fr

  6. Esophageal distensibility measurement: impact on clinical management and procedure length.

    Science.gov (United States)

    Ahuja, N K; Agnihotri, A; Lynch, K L; Hoo-Fatt, D; Onyimba, F; McKnight, M; Okeke, F C; Garcia, P; Dhalla, S; Stein, E; Pasricha, P J; Clarke, J O

    2017-08-01

    Luminal distensibility measurement has demonstrated relevance to various disease processes, though its effects on clinical decision-making have been less well understood. This study aims to characterize the clinical impact of impedance planimetry measurement as well as the learning curve associated with its use in the esophagus. A single provider performed distensibility measurement in conjunction with upper endoscopy for a variety of clinical indications with the functional lumen imaging probe (FLIP) over a period of 21 months. Procedural data were prospectively collected and, along with medical records, retrospectively reviewed. Seventy-three procedures (70 patients) underwent esophageal distensibility measurement over the timeline of this study. The most common procedural indications were known or suspected achalasia (32.9%), dysphagia with connective tissue disease (13.7%), eosinophilic esophagitis (12.3%), and dysphagia with prior fundoplication (9.6%). FLIP results independently led to a change in management in 29 (39.7%) cases and supported a change in management in an additional 15 (20.5%) cases. The most common change in management was a new or amended therapeutic procedure (79.5%). Procedural time added by distensibility measurement was greater among earlier cases than among later cases. The median time added overall was 5 minutes and 46 seconds. Procedural time added varied significantly by procedural indication, but changes in management did not. Distensibility measurement added meaningful diagnostic information that impacted therapeutic decision-making in the majority of cases in which it was performed. Procedural time added by this modality is typically modest and decreases with experience. © The Authors 2017. Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Cervical length measurement: comparison of transabdominal and transvaginal approach

    DEFF Research Database (Denmark)

    Westerway, Sue C; Pedersen, Lars Henning; Hyett, Jon

    2015-01-01

    accurately, particularly if the cervix is short. At 24–34 weeks, a policy of proceeding to TV scan if TA measurement is positive predictive value so is of limited value as a predictive tool for women attending with symptoms and signs...... of preterm labour > 24 weeks gestation. There is no value in TA assessment of the cervix > 36 weeks....

  8. The reliability of transabdominal cervical length measurement in a low-risk obstetric population: Comparison with transvaginal measurement.

    Science.gov (United States)

    Peng, Cheng-Ran; Chen, Chie-Pein; Wang, Kuo-Gon; Wang, Liang-Kai; Chen, Chen-Yu; Chen, Yi-Yung

    2015-04-01

    To determine the correlation between transabdominal (TA) and transvaginal (TV) cervical length measurement in a low-risk obstetric population in Taiwan. Women with a singleton pregnancy between 20 weeks and 24 weeks of gestation underwent postvoid TA and TV cervical length measurements. Differences between the measurements obtained using the two methods were evaluated. Two hundred and five women agreed to participate in the study. Paired TA and TV measurements were obtained in 174 women. The mean TA cervical length was 36.0 ± 4.9 mm and the mean TV cervical length was 37.6 ± 5.4 mm. The mean TA cervical length was shorter than the mean TV cervical length by 1.6 mm. The 5(th) percentile of TA and TV cervical length was 29 mm and 29.1 mm, respectively. The discrepancies between the two methods were not significantly correlated with maternal body mass index (BMI). All women with TV cervical length women in the present study, and the TA cervical length was closely correlated with the TV cervical length. The use of TA ultrasound could be an effective initial tool for cervical length screening in low-risk pregnant women. TA cervical length TV ultrasound. Copyright © 2015. Published by Elsevier B.V.

  9. Normal standards for kidney length as measured with US in premature infants

    International Nuclear Information System (INIS)

    Schlesinger, A.E.; Hedlund, G.L.; Pierson, W.P.; Null, D.M.

    1986-01-01

    In order to develop normal standards for kidney length in premature infants, the authors measured kidney length by US imaging in 39 (to date) premature infants less than 72 hours old and without known renal disease. Kidney length was compared with four different parameters of body size, including gestational age, birth weight, birth length, and body surface area. Similar standards have been generated previously for normal renal length as measured by US imaging in full-term infants and older children. These standards have proven utility in cases of congenital and acquired disorders that abnormally increase or decrease renal size. Scatter plots of kidney length versus body weight and kidney length versus body surface area conformed well to a logarithmic distribution, with a high correlation coefficient and close-fitting 95% confidence limits (SEE = 2.05)

  10. Subpicometer Length Measurement Using Semiconductor Laser Tracking Frequency Gauge

    Science.gov (United States)

    Thapa, Rajesh; Phillips, James D.; Rocco, Emanuele; Reasenburg, Robert D.

    2011-01-01

    We have demonstrated heretofore unattained distance precision of 0:14pm (2pm) incremental and 14nm (2.9 micrometers) absolute in a resonant (nonresonant) interferometer at an averaging time of 1 s, using inexpensive telecommunications diode lasers. We have controlled the main source of error, that due to spurious reflection and the resulting amplitude modulation. In the resonant interferometer, absolute distance precision is well under lambda/6. Therefore, after an interruption, an absolute distance measurement can be used to return to the same interferometer order.

  11. Effect of various digital processing algorithms on the measurement accuracy of endodontic file length.

    Science.gov (United States)

    Kal, Betül Ilhan; Baksi, B Güniz; Dündar, Nesrin; Sen, Bilge Hakan

    2007-02-01

    The aim of this study was to compare the accuracy of endodontic file lengths after application of various image enhancement modalities. Endodontic files of three different ISO sizes were inserted in 20 single-rooted extracted permanent mandibular premolar teeth and standardized images were obtained. Original digital images were then enhanced using five processing algorithms. Six evaluators measured the length of each file on each image. The measurements from each processing algorithm and each file size were compared using repeated measures ANOVA and Bonferroni tests (P = 0.05). Paired t test was performed to compare the measurements with the true lengths of the files (P = 0.05). All of the processing algorithms provided significantly shorter measurements than the true length of each file size (P 0.05). Decrease in mean error value was observed with increasing file size (P file length measurements when utilizing storage phosphor plates.

  12. Stride Segmentation during Free Walk Movements Using Multi-Dimensional Subsequence Dynamic Time Warping on Inertial Sensor Data

    Directory of Open Access Journals (Sweden)

    Jens Barth

    2015-03-01

    Full Text Available Changes in gait patterns provide important information about individuals’ health. To perform sensor based gait analysis, it is crucial to develop methodologies to automatically segment single strides from continuous movement sequences. In this study we developed an algorithm based on time-invariant template matching to isolate strides from inertial sensor signals. Shoe-mounted gyroscopes and accelerometers were used to record gait data from 40 elderly controls, 15 patients with Parkinson’s disease and 15 geriatric patients. Each stride was manually labeled from a straight 40 m walk test and from a video monitored free walk sequence. A multi-dimensional subsequence Dynamic Time Warping (msDTW approach was used to search for patterns matching a pre-defined stride template constructed from 25 elderly controls. F-measure of 98% (recall 98%, precision 98% for 40 m walk tests and of 97% (recall 97%, precision 97% for free walk tests were obtained for the three groups. Compared to conventional peak detection methods up to 15% F-measure improvement was shown. The msDTW proved to be robust for segmenting strides from both standardized gait tests and free walks. This approach may serve as a platform for individualized stride segmentation during activities of daily living.

  13. Stride time synergy in relation to walking during dual task

    DEFF Research Database (Denmark)

    Læssøe, Uffe; Madeleine, Pascal

    2012-01-01

    point of view elemental and performance variables may represent good and bad components of variability [2]. In this study we propose that the gait pattern can be seen as an on-going movement synergy in which each stride is corrected by the next stride (elemental variables) to ensure a steady gait...... (performance variable). AIM: The aim of this study was to evaluate stride time synergy and to identify good and bad stride variability in relation to walking during dual task. METHODS: Thirteen healthy young participants walked along a 2x5 meter figure-of-eight track at a self-selected comfortable speed....... RESULTS: The variance coefficient (CV%) increased significantly from 1.59 to 1.90 (psynergy approach, the good/bad variance ratio during single task was: 2.53 (CI95%: 2.07-3.00). When shifting to dual task the good/bad ratio was 2.28 (CI95...

  14. A paired-laser photogrammetric method for in situ length measurement of benthic fishes

    Science.gov (United States)

    Rizzo, Austin A.; Welsh, Stuart A.; Thompson, Patricia A.

    2017-01-01

    Photogrammetry, a technique to obtain measurements from photographs, may be a valid method for measuring lengths of rare, threatened, or endangered species. Photogrammetric methods of measurement are nonintrusive and reduce the possibility of physical damage or physiological stress associated with the capture and handling of individuals. We evaluated precision and accuracy of photogrammetric length measurements relative to board measurements of Greenside Darters Etheostoma blennioides and Variegate Darters E. variatum in an aquarium and applied photogrammetry in a field study of the Diamond Darter Crystallaria cincotta, a federally listed endangered species. Digital photographs were taken of each individual using a waterproof camera equipped with two parallel lasers. Photogrammetric length measurements were digitized with ImageJ software. Agreement between board and photogrammetric measurements were high for Greenside and Variegate darters. The magnitude of differences was small between direct and photogrammetric measurements, ranging from 0.6% to 3.1%, depending on the species measured and the type of measurement taken. These results support photogrammetry as a useful method for obtaining length measurements of benthic stream fishes. Photogrammetric methods allowed for length measurements and an assessment of length frequency of 199 Diamond Darters, informative data for management that could not be collected with conventional measuring-board methods.

  15. Experimental Investigation Of The Real Contact Arc Length Measurement In The Cylindrical Plunge Grinding

    Directory of Open Access Journals (Sweden)

    Pang Jingzhu

    2016-01-01

    Full Text Available The real contact arc length in grinding is one of the most important indicators in investigating of the material removal mechanism for precision machining. It is generally affected by a combination of plastic and thermal deformations in the machining process. This paper will provide a systematic investigation of the contact arc length in the cylindrical grinding of titanium alloy Ti-6Al-4V. A series of single grit experiments and grinding temperature measurements, together with FEM simulation, will be utilized to determine the real contact arc length. The contact behavior between a grinding wheel and the workpiece was investigated by the contact time in the workpice surface temperature curves. It was found that in FEM simulation, the real contact length was about 2 times of the geometric length. With the experimental results of the different grinding parameters, the real contact lengths calculated by temperature curves were about 1.5 - 2 times of the geometric length.

  16. Leg heating and cooling influences running stride parameters but not running economy.

    Science.gov (United States)

    Folland, J P; Rowlands, D S; Thorp, R; Walmsley, A

    2006-10-01

    To evaluate the effect of temperature on running economy (RE) and stride parameters in 10 trained male runners (VO2peak 60.8 +/- 6.8 ml . kg (-1) . min (-1)), we used water immersion as a passive temperature manipulation to contrast localised pre-heating, pre-cooling, and thermoneutral interventions prior to running. Runners completed three 10-min treadmill runs at 70 % VO2peak following 40 min of randomised leg immersion in water at 21.0 degrees C (cold), 34.6 degrees C (thermoneutral), or 41.8 degrees C (hot). Treadmill runs were separated by 7 days. External respiratory gas exchange was measured for 30 s before and throughout the exercise and stride parameters were determined from video analysis in the sagittal plane. RE was not affected by prior heating or cooling with no difference in oxygen cost or energy expenditure between the temperature interventions (average VO2 3rd-10th min of exercise: C, 41.6 +/- 3.4 ml . kg (-1) . min (-1); TN, 41.6 +/- 3.0; H, 41.8 +/- 3.5; p = 0.94). Exercise heart rate was affected by temperature (H > TN > C; p exchange and minute ventilation/oxygen consumption ratios were greater in cold compared with thermoneutral (p economy despite changes in stride parameters that might indicate restricted muscle-tendon elasticity after pre-cooling. Larger changes in stride mechanics than those produced by the current temperature intervention are required to influence running economy.

  17. Utility of telomere length measurements for age determination of humpback whales

    Directory of Open Access Journals (Sweden)

    Morten Tange Olsen

    2014-12-01

    Full Text Available This study examines the applicability of telomere length measurements by quantitative PCR as a tool for minimally invasive age determination of free-ranging cetaceans. We analysed telomere length in skin samples from 28 North Atlantic humpback whales (Megaptera novaeangliae, ranging from 0 to 26 years of age. The results suggested a significant correlation between telomere length and age in humpback whales. However, telomere length was highly variable among individuals of similar age, suggesting that telomere length measured by quantitative PCR is an imprecise determinant of age in humpback whales. The observed variation in individual telomere length was found to be a function of both experimental and biological variability, with the latter perhaps reflecting patterns of inheritance, resource allocation trade-offs, and stochasticity of the marine environment.

  18. Agreement between the GAITRite walkway system and a stopwatch-footfall count method for measurement of temporal and spatial gait parameters.

    Science.gov (United States)

    Youdas, James W; Hollman, John H; Aalbers, Monica J; Ahrenholz, Holly N; Aten, Rebecca A; Cremers, Joseph J

    2006-12-01

    To determine the agreement for measurements of stride length, cadence, and walking speed obtained from the GAITRite system and the stopwatch-footfall count technique. Criterion standard. Research laboratory in a physical therapy education program. Forty healthy volunteers (13 men, 27 women) without lower-extremity injury. Participants walked across a GAITRite mat with embedded pressure sensors at their self-selected walking speed. Simultaneously, an examiner used a stopwatch to record the elapsed time necessary to cross the mat and counted the number of complete footfalls. Walking speed, cadence, and stride-length measures were compared between the GAITRite system and the stopwatch-footfall count technique. Correlation coefficients comparing both systems were .97 for walking speed, .75 for cadence, and .85 for stride length. Ninety-five percent of the time we would expect the between-methods differences to range between .09 and -.05m/s for walking speed, between -1.5 and -24.3 steps/min for cadence, and between .01 and .37m for stride length. This study shows that the GAITRite and stopwatch-footfall count methods lack clinically acceptable agreement for the measurements of cadence and stride length in a group of healthy volunteers walking at their self-selected speeds. Clinicians who require precise measurement of cadence and stride length should consider using the GAITRite system instead of the stopwatch-footfall count technique.

  19. Stride Leg Ground Reaction Forces Predict Throwing Velocity in Adult Recreational Baseball Pitchers.

    Science.gov (United States)

    McNally, Michael P; Borstad, John D; Oñate, James A; Chaudhari, Ajit M W

    2015-10-01

    Ground reaction forces produced during baseball pitching have a significant impact in the development of ball velocity. However, the measurement of only one leg and small sample sizes in these studies curb the understanding of ground reaction forces as they relate to pitching. This study aimed to further clarify the role ground reaction forces play in developing pitching velocity. Eighteen former competitive baseball players with previous high school or collegiate pitching experience threw 15 fastballs from a pitcher's mound instrumented to measure ground reaction forces under both the drive and stride legs. Peak ground reaction forces were recorded during each phase of the pitching cycle, between peak knee height and ball release, in the medial/lateral, anterior/posterior, and vertical directions, and the peak resultant ground reaction force. Stride leg ground reaction forces during the arm-cocking and arm-acceleration phases were strongly correlated with ball velocity (r2 = 0.45-0.61), whereas drive leg ground reaction forces showed no significant correlations. Stepwise linear regression analysis found that peak stride leg ground reaction force during the arm-cocking phase was the best predictor of ball velocity (r2 = 0.61) among drive and stride leg ground reaction forces. This study demonstrates the importance of ground reaction force development in pitching, with stride leg forces being strongly predictive of ball velocity. Further research is needed to further clarify the role of ground reaction forces in pitching and to develop training programs designed to improve upper extremity mechanics and pitching performance through effective force development.

  20. Automatic measurement of axial length of human eye using three-dimensional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Watanabe, Masaki; Kiryu, Tohru

    2011-01-01

    The measurement of axial length and the evaluation of three dimensional (3D) form of an eye are essential to evaluate the mechanism of myopia progression. We propose a method of automatic measurement of axial length including adjustment of the pulse sequence of short-term scan which could suppress influence of eyeblink, using a magnetic resonance imaging (MRI) which acquires 3D images noninvasively. Acquiring T 2 -weighted images with 3.0 tesla MRI device and eight-channel phased-array head coil, we extracted left and right eye ball images, and then reconstructed 3D volume. The surface coordinates were calculated from 3D volume, fitting the ellipsoid model coordinates with the surface coordinates, and measured the axial length automatically. Measuring twenty one subjects, we compared the automatically measured values of axial length with the manually measured ones, then confirmed significant elongation in the axial length of myopia compared with that of emmetropia. Furthermore, there were no significant differences (P<0.05) between the means of automatic measurements and the manual ones. Accordingly, the automatic measurement process of axial length could be a tool for the elucidation of the mechanism of myopia progression, which would be suitable for evaluating the axial length easily and noninvasively. (author)

  1. Significance of axial length monitoring in children with congenital cataract and update of measurement methods.

    Science.gov (United States)

    Zhan, Jiao; Lin, Haotian; Zhang, Xinyu; Chen, Weirong; Liu, Yizhi

    2013-06-01

    Congenital cataract is the main cause of blindness in children, with significantly varying treatment effects. The development of axial length is an important factor that affects the prognosis of these children. However, when compared with the eyes of normal children, the mechanism of growth of the axial length is so complicated that the reported findings differ significantly in terms of the measuring apparatus, assessment methods, and statistical outcome, making the rule of axial length development still unclear. In this paper, we first review the process of axial length development in normal healthy children and compare different hypotheses about certain factors that could affect the development of axial length. The results of some current research about the characteristics of axial length development in congenital cataract children are then reviewed. Lastly, the advantages and disadvantages of current axial length measurements methods are compared and analyzed. The purpose of this review is to improve our understanding of the complexity and importance of axial length development and to suggest better use of axial length monitoring measurements in congenital cataract children for pediatric ophthalmologists, with the hope of offering assistance that will enhance long-term therapeutic effects for these children.

  2. Measurement accuracy and reliability of tooth length on conventional and CBCT reconstructed panoramic radiographs

    Science.gov (United States)

    Flores-Mir, Carlos; Rosenblatt, Mark R; Major, Paul W.; Carey, Jason P.; Heo, Giseon

    2014-01-01

    INTRODUCTION: This in vivo study assessed accuracy and reliability of tooth length measurements obtained from conventional panoramic radiographs and CBCT panoramic reconstructions to that of a digital caliper (gold standard). METHODS: The sample consisted of subjects who had CBCT and conventional panoramic radiographic imaging and who required maxillary premolar extraction for routine orthodontic treatment. A total of 48 teeth extracted from 26 subjects were measured directly with digital calipers. Radiographic images were scanned and digitally measured in Dolphin 3D software. Accuracy of tooth length measurements made by CBCT panoramic reconstructions, conventional panoramic radiographs and digital caliper (gold standard) were compared to each other by repeated measures one-way ANOVA with Bonferroni correction and by single measures intraclass correlation coefficient. RESULTS: Repeated root length measures with digital calipers, panoramic radiographs and CBCT constructed panoramic-like images were all individually highly reliable. Compared to the caliper (gold standard), tooth measurements obtained from conventional panoramic radiographs were on average 6.3 mm (SD = 2.0 mm) longer, while tooth measurements from CBCT panoramic reconstructions were an average of 1.7 mm (SD = 1.2 mm) shorter. CONCLUSIONS: In comparison to actual tooth lengths, conventional panoramic radiographs were relatively inaccurate, overestimating the lengths by 29%, while CBCT panoramic reconstructions underestimated the lengths by 4%. PMID:25715716

  3. Measurement of subpicosecond bunch lengths using coherent Smith-Purcell radiation

    Directory of Open Access Journals (Sweden)

    S. E. Korbly

    2006-02-01

    Full Text Available We report the use of coherent Smith-Purcell radiation to measure the bunch length of femtosecond-scale, 15 MeV electron bunches produced by a 17 GHz rf accelerator. The Smith-Purcell radiation was produced by passing a train of electron bunches above a metal grating. The radiation was verified as Smith-Purcell radiation by measuring the resonance condition, dependence on beam current, and dependence on beam height above the grating. Measurements of the intensity of the radiation vs emission angle were analyzed to obtain the bunch length. The accelerator was operated in two different modes, producing bunches that were determined to have bunch lengths of 600 and 1000±200  fs. These nondestructive bunch length measurements were found to agree well with an independent, but destructive, measurement using a microwave deflecting cavity.

  4. Blood and dried blood spot telomere length measurement by qPCR: assay considerations.

    Directory of Open Access Journals (Sweden)

    DeAnna L Zanet

    Full Text Available Measurement of telomere length is crucial for the study of telomere maintenance and its role in molecular pathophysiology of diseases and in aging. Several methods are used to measure telomere length, the choice of which usually depends on the type and size of sample to be assayed, as well as cost and throughput considerations. The goal of this study was to investigate the factors that may influence the reliability of qPCR-based relative telomere length measurements in whole blood. Day to day intra-individual variability, types of blood anticoagulant, sample storage conditions, processing and site of blood draw were investigated. Two qPCR-based methods to measure telomere length (monoplex vs. multiplex were also investigated and showed a strong correlation between them. Freezing and thawing of the blood and storage of the blood at 4°C for up to 4 days did not affect telomere length values. Telomere lengths in dried blood spots were significantly higher than both whole blood and peripheral mononuclear blood cells, and were highly correlated with both. We found that telomere length measurements were significantly higher in dried blood spots collected directly from fingertip prick compared to dried blood spots prepared with anticoagulated whole blood collected from the finger, and non-blotted whole blood taken from both finger and arm venipuncture. This suggests that DNA from cells blotted on paper is not equivalent to that collected from venipuncture whole blood, and caution should be taken when comparing between blood sample types.

  5. Comparison of Wright's Formula and the Dunn Method for Measuring the Umbilical Arterial Catheter Insertion Length

    Directory of Open Access Journals (Sweden)

    Se-ra Min

    2015-04-01

    Conclusion: The use of Wright's formula overall results in superior correct placement of the UAC tip. It may be a more accurate and practical method than the conventional practice for measuring the UAC insertion length in newborns.

  6. Automatic species recognition, length measurement and weight determination, using the CatchMeter computer vision system

    OpenAIRE

    Svellingen, Cato; Totland, Bjørn; White, Darren; Øvredal, Jan Tore

    2006-01-01

    The collection of biological data on species composition and individual length and weight of specimen has always been an important part of fisheries research. Traditionally, the collected information has been recorded on paper prior to being entered into a computer for analysis. Electronic measuring boards that record length measurements, such as the FishMeter (Øvredal and Totland, 2000), have made the data collection process more efficient and reliable. In this contribution we describe a vis...

  7. Preliminary result of bunch length measurement using a modified Michelson interferometer

    International Nuclear Information System (INIS)

    Lin Xuling; Luo Feng; Bei Hua; Dai Zhimin; Chinese Academy of Sciences, Beijing; Zhang Jianbing; Lu Shanliang; Yu Tiemin

    2009-01-01

    Based on the femtosecond accelerator device which was built at the Shanghai Institute of Applied Physics (SINAP), recently a modified far infrared Michelson interferometer has been developed to measure the length of electron bunches via the optical autocorrelation method. Compared with our former normal Michelson interferometer, we use a hollow retroreflector instead of a flat mirror as the reflective mirror. The experimental setup and results of the bunch length measurement will be described in this paper. (authors)

  8. Measurement and restoration of equality in length of the lower limbs in total hip replacement

    Energy Technology Data Exchange (ETDEWEB)

    Hoikka, V.; Paavilainen, T.; Lindholm, T.S.; Turula, K.B.; Ylikoski, M.

    1987-08-01

    Alteration of the length of the lower limb was measured in 39 patients undergoing total hip replacement. Radiographs were taken in the erect posture prior to operation and 6 months postoperatively. The inequality of limb length was measured by the difference between the height of the vertices of the fermoral heads and by the difference between the lowest points of the ischial tuberosities. The change of the length was measured intraoperatively as the difference observed between two reference points: One above the acetabulum and the other on the proximal femur. Good correlation was obtained between the change of the limb length made intraoperatively and the change in the limb length using the ischial tuberosities as reference points; no correlation was observed when the vertices of the femoral heads were the reference points. Inequality of limb length can be radiologically determined before and after total hip arthroplasty. Femoral and prosthetic heads are not good reference points for measurement. The difference in the height of ischial tuberosities demonstrates inequality of limb functional length as it reflects the tilting of the pelvis.

  9. Polarization gating enables sarcomere length measurements by laser diffraction in fibrotic muscle

    Science.gov (United States)

    Young, Kevin W.; Dayanidhi, Sudarshan; Lieber, Richard L.

    2014-11-01

    Sarcomere length is a key parameter commonly measured in muscle physiology since it dictates striated muscle active force. Laser diffraction (LD)-based measurements of sarcomere length are time-efficient and sample a greater number of sarcomeres compared with traditional microscopy-based techniques. However, a limitation to LD techniques is that signal quality is severely degraded by scattering events as photons propagate through tissue. Consequently, sarcomere length measurements are unattainable when the number of scattering events is sufficiently large in muscle tissue with a high scattering probability. This occurs in fibrotic skeletal muscle seen in muscular dystrophies and secondary to tissue trauma, thus eliminating the use of LD to study these skeletal muscle ailments. Here, we utilize polarization gating to extract diffracted signals that are buried in noise created by scattering. Importantly, we demonstrate that polarization-gated laser diffraction (PGLD) enables sarcomere length measurements in muscles from chronically immobilized mice hind limbs; these muscles have a substantial increase of intramuscular connective tissue that scatter light and disable sarcomere length measurements by traditional LD. Further, we compare PGLD sarcomere lengths to those measured by bright field (BF) and confocal microscopy as positive controls and reveal a significant bias of BF but not of confocal microscopy.

  10. The Length of a Pestle: A Class Exercise in Measurement and Statistical Analysis.

    Science.gov (United States)

    O'Reilly, James E.

    1986-01-01

    Outlines the simple exercise of measuring the length of an object as a concrete paradigm of the entire process of making chemical measurements and treating the resulting data. Discusses the procedure, significant figures, measurement error, spurious data, rejection of results, precision and accuracy, and student responses. (TW)

  11. Tyre contact length on dry and wet road surfaces measured by three-axial accelerometer

    Science.gov (United States)

    Matilainen, Mika; Tuononen, Ari

    2015-02-01

    We determined the tyre contact length on dry and wet roads by measuring the accelerations of the inner liner with a three-axial accelerometer. The influence of the tyre pressure, driving velocity, and tread depth on the contact length was studied in both types of road surface conditions. On dry asphalt the contact length was almost constant, regardless of the driving velocity. On wet asphalt the presence of water could be detected even at low driving velocities (e.g. 20 km/h for a worn tyre) as the contact length began to decrease from that found in the dry asphalt situation. In addition to improving the performance of active safety systems and driver warning systems, the contact length information could be beneficial for classifying and studying the aquaplaning behaviour of tyres.

  12. Paediatric renal length measurements from ultrasound and DMSA scans: does clinical practice reflect theoretical normal values?

    International Nuclear Information System (INIS)

    Que, L.; Rutland, M.D.; Hassan, I.M.

    1999-01-01

    Full text: Renal length measurement is a routine part of ultrasound examination in children and those results are plotted on a normogram style graph, so that each child's results are compared to a normal range (mean ± 2 S.D.). Renal length measurements from the posterior oblique views of dimercaptosuccinic acid (DMSA) scans in our department have not always correlated well with the ultrasound measurements on the same patients. Renal lengths from the DMSA scans of 120 patients with apparently normal kidneys were recorded and used to generate a normogram of renal length at different ages (0.5-7 years). This DMSA normogram was compared to the ultrasound (US) normogram used in the Paediatric Radiology Department, and it showed slight differences in renal lengths (3-8 mm), but that the US normogram had smaller coefficients of variation (US = 6.6%, NM 8.3%), implying a 'tighter' normal range. 39 of these patients had DMSA and ultrasound measurements of renal length within 3 months, and these were studied first by calculating the mean and CV values for different age groups, and then by plotting individual renal lengths on the appropriate normograms. The measured data produced much greater variability in the ultrasound measurements than the DTPA measurements, and the individual points produced 4/78 (5.1%) abnormal results for DMSA, but 21/78 (26.9%) abnormal results for ultrasound. Thus, in routine clinical use, using patients with apparently normal kidneys, ultrasound was unable to match the 'normal range' set by their current normogram, but the nuclear medicine showed 5.1% of values outside the normal (DMSA) range, which was completely appropriate for a range of ± 2 standard deviations

  13. The accuracy of axial length measurements in cases of macula-off retinal detachment.

    Science.gov (United States)

    Abou-Shousha, Mohsen; Helaly, Hany Ahmed; Osman, Ihab Mohamed

    2016-04-01

    To assess the accuracy of axial length measurements in cases of macula-off retinal detachment using different methods (optical biometry, A-scan ultrasound, and combined applanation vector-A/B-scan biometry). This prospective clinical study included 100 eyes of 100 patients who underwent vitrectomy alone or phacovitrectomy for macula-off retinal detachment. All patients included signed an informed consent. Preoperative examination of the patients included recording the axial length measurements using optical biometry, A-scan ultrasound, and combined applanation vector-A/B-scan biometry. The mean postoperative IOLMaster axial length after macular reattachment was 26.11 ± 2.91 mm. The mean preoperative IOLMaster axial length with macula-off was 25.32 ± 2.72 mm. The mean preoperative A-scan axial length with macula-off was 25.29 ± 2.80 mm. The mean preoperative vector-A/B-scan axial length with macula-off was 26.03 ± 2.90 mm. The preoperative vector-A/B-scan mean absolute error was 0.59 ± 0.48 D (range, 0.10-2.25 D). Regular methods (optical biometry and A-scan biometry) of measuring the axial length in cases with a detached macula proved to be variable and less accurate. The vector-A/B-scan offered good measurements of the actual axial length in the patients. This was reflected on more accurate postoperative refractive outcome. Copyright © 2016 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  14. 16 CFR 500.12 - Measurement of commodities by length and width, how expressed.

    Science.gov (United States)

    2010-01-01

    ... square foot (929 cm2) be expressed in terms of length and width in linear measure. The customary inch... of 1 square foot (929 cm2) or more, but less than 4 square feet (37.1 dm2), be expressed in terms of... (10.16 cm) or less, the declaration of net quantity shall be expressed in terms of width and length in...

  15. Research on the measurement technology of effective arm length of swing arm profilometer

    Science.gov (United States)

    Chen, Lin; Jing, Hongwei; Wei, Zhongwei; Li, Jie; Cao, Xuedong

    2014-09-01

    When the swing arm profilometer(SAP) measuring the mirror, the effective arm length of SAP which haves an obvious influence on the measurement results of the mirror surface shape needs to be measured accurately. It requires the measurement uncertainty of the effective arm length to reach 10μm in order to meet the measurement requirements, in this paper, we present a kind of technology based on laser tracker to measure the effective arm length of SAP. When the swing arm rotates around the shaft axis of swing arm rotary stage, the probe and two laser tracker balls form three sections of circular arc around the shaft axis of swing arm rotary stage in space. Laser tracker tracks and measures the circular arcs of two laser tracker balls, the center coordinates of the circular plane of circular arc can be calculated by data processing. The linear equation that passes through the two center coordinates is the equation of the shaft axis of rotary stage, the vertical distance from the probe to the shaft axis of rotary stage which can be calculated refer to the equation from the point to the line is the effective arm length. After Matlab simulation, this measurement method can meet the measurement accuracy.

  16. Reliability of linear distance measurement for dental implant length with standardized periapical radiographs

    International Nuclear Information System (INIS)

    Wakoh, Mamoru; Harada, Takuya; Otonari, Takamichi

    2006-01-01

    The purpose of this study was to investigate the accuracy of distance measurements of implant length based on periapical radiographs compared with that of other modalities. We carried out an experimental trial to compare precision in distance measurement. Dental implant fixtures were buried in the canine and first molar regions. These were then subjected to periapical (PE) radiography, panoramic (PA) radiography conventional (CV) and medical computed (CT) tomography. The length of the implant fixture on each film was measured by nine observers and degree of precision was statistically analyzed. The precision of both PE radiographs and CT tomograms was closest at the highest level. Standardized PE radiography, in particular, was superior to CT tomography in the first molar region. This suggests that standardized PE radiographs should be utilized as a reliable modality for longitudinal and linear distance measurement, depending on implant length at local implantation site. (author)

  17. Contact Angle Measurement of Small Capillary Length Liquid in Super-repelled State.

    Science.gov (United States)

    Liu, Tingyi Leo; Kim, Chang-Jin Cj

    2017-04-07

    The difficulty of measuring very large contact angles (>150 degrees) has become more relevant with the increased popularity of super-repellent surfaces. Measurement is more difficult for dynamic contact angles, for which theoretical profiles do not fit well, and small capillary length liquids, whose sessile droplets sag by gravity. Here, we expand the issue to the limit by investigating dynamic contact angles of liquids with an extremely small capillary length (contact angles can be measured with a consistent accuracy despite their vastly different capillary lengths if one keeps the lens magnification inversely proportional to the capillary length. Verifying the droplet equator height is a key parameter, we propose a new Bond number defined by the equator height and optical resolution to represent the measurement accuracy of large contact angles. Despite negligible improvement for most liquids today, the proposed approach teaches how to measure very large contact angles with consistent accuracy when any of the liquids in consideration has a capillary length below 1.0 mm.

  18. Spherical aberration compensation method for long focal-length measurement based on Talbot interferometry

    Science.gov (United States)

    Luo, Yupeng; Huang, Xiao; Bai, Jian; Du, Juan; Liu, Qun; Luo, Yujie; Luo, Jia

    2017-08-01

    Large-aperture and long focal-length lens is widely used in high energy laser system. The method based on Talbot interferometry is a reliable method to measure the focal length of such elements. By employing divergent beam and two gratings of different periods, this method could realize full-aperture measurement, higher accuracy and better repeatability. However, it does not take into account the spherical aberration of the measured lens resulting in the moiré fringes bending, which will introduce measurement error. Furthermore, in long-focal measurement with divergent beam, this error is an important factor affecting the measurement accuracy. In this paper, we propose a new spherical aberration compensation method, which could significantly reduce the measurement error. Characterized by central-symmetric scanning window, the proposed method is based on the relationship between spherical aberration and the lens aperture. Angle data of moiré fringes in each scanning window is retrieved by Fourier analysis and statistically fitted to estimate a globally optimum value for spherical-aberration-free focal length calculation. Simulation and experiment have been carried out. Compared to the previous work, the proposed method is able to reduce the relative measurement error by 50%. The effect of scanning window size and shift step length on the results is also discussed.

  19. Air method measurements of apple vessel length distributions with improved apparatus and theory

    Science.gov (United States)

    Shabtal Cohen; John Bennink; Mel Tyree

    2003-01-01

    Studies showing that rootstock dwarfing potential is related to plant hydraulic conductance led to the hypothesis that xylem properties are also related. Vessel length distribution and other properties of apple wood from a series of varieties were measured using the 'air method' in order to test this hypothesis. Apparatus was built to measure and monitor...

  20. Strides towards substantive democracy and gender perspective in ...

    African Journals Online (AJOL)

    Strides towards substantive democracy and gender perspective in the 21st century of Africa. Kelvin Bribena. Abstract. The weakness of the multiparty political system in Africa will be analysed in line with accepted standards for transparency, electoral provisions, as well as the free and fair establishment, assembly and ...

  1. Standing Height and its Estimation Utilizing Foot Length Measurements in Adolescents from Western Region in Kosovo

    Directory of Open Access Journals (Sweden)

    Stevo Popović

    2017-10-01

    Full Text Available The purpose of this research is to examine standing height in both Kosovan genders in the Western Region as well as its association with foot length, as an alternative to estimating standing height. A total of 664 individuals (338 male and 326 female participated in this research. The anthropometric measurements were taken according to the protocol of ISAK. The relationships between body height and foot length were determined using simple correlation coefficients at a ninety-five percent confidence interval. A comparison of means of standing height and foot length between genders was performed using a t-test. After that a linear regression analysis were carried out to examine extent to which foot length can reliably predict standing height. Results displayed that Western Kosovan male are 179.71±6.00cm tall and have a foot length of 26.73±1.20cm, while Western Kosovan female are 166.26±5.23cm tall and have a foot length of 23.66±1.06cm. The results have shown that both genders made Western-Kosovans a tall group, a little bit taller that general Kosovan population. Moreover, the foot length reliably predicts standing height in both genders; but, not reliably enough as arm span. This study also confirms the necessity for developing separate height models for each region in Kosovo as the results from Western-Kosovans don’t correspond to the general values.

  2. Effect of different levels of sharpness processing filter on the measurement accuracy of endodontic file length

    Directory of Open Access Journals (Sweden)

    Nastaran Farhadi

    2016-01-01

    Full Text Available Introduction: The present study was undertaken to evaluate the effect of different levels of sharpness processing filter on the accuracy of endodontic file length determination using digital periapical radiography. Materials and Methods: Forty human single-rooted permanent teeth were selected and International Organization for Standardization (ISO #08 K-files were inserted into the root canals of the teeth. The file lengths were measured with a digital caliper as the gold standard. Digital periapical images were obtained using a phosphor storage plate as a detector. Three levels of sharpness tool of Scanora software program version 5.1 was used to produce enhanced images: Sharpen 1 (mild level, Sharpen 2 (moderate level, and Sharpen 3 (high level. Two radiologists and two endodontists measured file lengths on the original and enhanced images. The measurements were compared using repeated measures ANOVA and Bonferroni tests (α = 0.05. Results: There were no significant differences between the measurement accuracy of original images and that of the Sharpen 1 and Sharpen 2 enhanced images (P > 0.05. However, significant differences were found between the measurement accuracy of original and that of the Sharpen 3 enhanced images (P 0.05. Conclusion: The application of mild and moderate levels of sharpness processing filter did not influence the accuracy of endodontic file length determination. However, high-level sharpness processing filter is not recommended due to its unfavorable effects on measurement accuracy.

  3. The use of an individual jig in measuring tooth length changes.

    Science.gov (United States)

    Brezniak, Naphtali; Goren, Shay; Zoizner, Ronen; Dinbar, Ariel; Arad, Arnon; Wasserstein, Atalia; Heller, Moshe

    2004-12-01

    The parallel periapical radiographic technique hides several problems that might affect the image seen on the film. To overcome these problems a special jig with an external wire attached to the tooth surface and parallel to its long axis was suggested. This study examines the accuracy of using an external object for measuring root length differences due to angular changes between the tooth and the film. The rule of three was used for all calculations as a compensating formula. A human central incisor was placed in a special jig. Two different wire lengths (11.8 +/- 0.1 mm and 16 +/- 0.1 mm) were attached to the tooth in six different ways. The tooth was radiographed at four different film to tooth angulations. The tooth and wire lengths were measured on the model itself and directly on the scanned film on a computer monitor. The results reveal that a wire, placed nine mm from the crown and parallel to the long axis of the tooth was the best jig for accurately measuring tooth length changes. Neither palatal nor buccal metal wires, intimately attached to the crown of the tooth, can serve as a tool to measure tooth length changes. The study could not find a way to skip the need for a cephalometric radiograph to verify the parallelism between the wire and the long axis of the tooth for this matter.

  4. Persistent fluctuations in stride intervals under fractal auditory stimulation.

    Science.gov (United States)

    Marmelat, Vivien; Torre, Kjerstin; Beek, Peter J; Daffertshofer, Andreas

    2014-01-01

    Stride sequences of healthy gait are characterized by persistent long-range correlations, which become anti-persistent in the presence of an isochronous metronome. The latter phenomenon is of particular interest because auditory cueing is generally considered to reduce stride variability and may hence be beneficial for stabilizing gait. Complex systems tend to match their correlation structure when synchronizing. In gait training, can one capitalize on this tendency by using a fractal metronome rather than an isochronous one? We examined whether auditory cues with fractal variations in inter-beat intervals yield similar fractal inter-stride interval variability as isochronous auditory cueing in two complementary experiments. In Experiment 1, participants walked on a treadmill while being paced by either an isochronous or a fractal metronome with different variation strengths between beats in order to test whether participants managed to synchronize with a fractal metronome and to determine the necessary amount of variability for participants to switch from anti-persistent to persistent inter-stride intervals. Participants did synchronize with the metronome despite its fractal randomness. The corresponding coefficient of variation of inter-beat intervals was fixed in Experiment 2, in which participants walked on a treadmill while being paced by non-isochronous metronomes with different scaling exponents. As expected, inter-stride intervals showed persistent correlations similar to self-paced walking only when cueing contained persistent correlations. Our results open up a new window to optimize rhythmic auditory cueing for gait stabilization by integrating fractal fluctuations in the inter-beat intervals.

  5. Measuring telomere length for the early detection of precursor lesions of esophageal squamous cell carcinoma

    International Nuclear Information System (INIS)

    Lin, Shih-Wen; Wang, Guo-Qing; Wei, Wen-Qiang; Lu, Ning; Taylor, Philip R; Qiao, You-Lin; Dawsey, Sanford M; Abnet, Christian C; Freedman, Neal D; Murphy, Gwen; Risques, Rosana; Prunkard, Donna; Rabinovitch, Peter; Pan, Qin-Jing; Roth, Mark J

    2013-01-01

    Esophageal cancer is the sixth leading cause of cancer death worldwide; current early detection screening tests are inadequate. Esophageal balloon cytology successfully retrieves exfoliated and scraped superficial esophageal epithelial cells, but cytologic reading of these cells has poor sensitivity and specificity for detecting esophageal squamous dysplasia (ESD), the precursor lesion of esophageal squamous cell carcinoma (ESCC). Measuring telomere length, a marker for chromosomal instability, may improve the utility of balloon cytology for detecting ESD and early ESCC. We examined balloon cytology specimens from 89 asymptomatic cases of ESD (37 low-grade and 52 high-grade) and 92 age- and sex-matched normal controls from an esophageal cancer early detection screening study. All subjects also underwent endoscopy and biopsy, and ESD was diagnosed histopathologically. DNA was extracted from the balloon cytology cells, and telomere length was measured by quantitative PCR. A receiver operating characteristic (ROC) curve was plotted for telomere length as a diagnostic marker for high-grade dysplasia. Telomere lengths were comparable among the low- and high-grade dysplasia cases and controls, with means of 0.96, 0.96, and 0.92, respectively. The area under the ROC curve was 0.55 for telomere length as a diagnostic marker for high-grade dysplasia. Further adjustment for subject characteristics, including sex, age, smoking, drinking, hypertension, and body mass index did not improve the use of telomere length as a marker for ESD. Telomere length of esophageal balloon cytology cells was not associated with ESCC precursor lesions. Therefore, telomere length shows little promise as an early detection marker for ESCC in esophageal balloon samples

  6. Interpretation of scanning electron microscope measurements of minority carrier diffusion lengths in semiconductors

    Science.gov (United States)

    Flat, A.; Milnes, A. G.

    1978-01-01

    In scanning electron microscope (SEM) injection measurements of minority carrier diffusion lengths some uncertainties of interpretation exist when the response current is nonlinear with distance. This is significant in epitaxial layers where the layer thickness is not large in relation to the diffusion length, and where there are large surface recombination velocities on the incident and contact surfaces. An image method of analysis is presented for such specimens. A method of using the results to correct the observed response in a simple convenient way is presented. The technique is illustrated with reference to measurements in epitaxial layers of GaAs. Average beam penetration depth may also be estimated from the curve shape.

  7. Competitive Balance Measures in Sports Leagues: The Effects of Variation in Season Length

    OpenAIRE

    P Dorian Owen; Nicholas King

    2013-01-01

    Appropriate measurement of competitive balance is a cornerstone of the economic analysis of professional sports leagues. We examine the distributional properties of the ratio of standard deviations (RSD) of points percentages, the most widely used measure of competitive balance in the sports economics literature, in comparison with other standard-deviation-based measures. Simulation methods are used to evaluate the effects of changes in season length on the distributions of competitive balanc...

  8. Focal length measurement of a varifocal liquid lens with capacitance detection

    Science.gov (United States)

    Noda, Kentaro; Binh-Khiem, Nguyen; Takei, Yusuke; Takahata, Tomoyuki; Matsumoto, Kiyoshi; Shimoyama, Isao

    2014-04-01

    This paper reports on a detailed deformation model of varifocal liquid lenses fabricated by Parylene-on-liquid-deposition (POLD), which can be applied to measure and adjust the focal length of such lenses without using extra sensors or sensing mechanisms. The lens was fabricated by encapsulating a liquid between a transparent electrode and a polymer film that was covered with a metal electrode. When voltage is applied to the two electrodes, the lens deforms due to the electrostatic force, and its focal length and the capacitance between the two electrodes change simultaneously. This characteristic enables the focal length of the lens to be adjusted and detected by measuring the capacitance change. The focal length of the fabricated varifocal liquid lens changed from 153.6 to 82.6 mm by applying 150-V. The focal length change of the liquid lens was calculated from the change in its capacitance. Finally, to confirm the efficiency of this varifocal liquid lens, we fabricated a confocal distance sensor using the lens for laser scanning and demonstrated that this system can be used to measure distances of 94-140 mm with an average error of 0.83 mm and a standard deviation of 0.77 mm.

  9. Foot length measurements of newborns of high and low risk pregnancies

    Directory of Open Access Journals (Sweden)

    Ana Karina Marques Salge

    Full Text Available Abstract OBJECTIVE Comparing foot length measurements of newborns in high and low risk pregnancies at a public hospital in Goiânia, GO, Brazil. METHOD A cross-sectional study carried out between April, 2013 and May, 2015, with a sample consisting of 180 newborns; 106 infants of women from high-risk pregnancies and 74 of women from low-risk pregnancies. Data were descriptively analyzed. Foot length measurement was performed using a stiff transparent plastic ruler, graduated in millimeters. The length of both feet was measured from the tip of the hallux (big toe to the end of the heel. RESULTS A statistically significant relationship was found between the foot length and newborn’s weight, between the cephalic and thoracic perimeters in the high-risk group and between the cephalic perimeter in the control group. CONCLUSION There is a need for creating cut-off points to identify newborns with intrauterine growth disorders using foot length.

  10. First working group meeting on the minority carrier diffusion length/lifetime measurement: Results of the round robin lifetime/diffusion length tests

    Energy Technology Data Exchange (ETDEWEB)

    Cudzinovic, M; Sopori, B [comp.

    1995-11-01

    As was noted in the cover letter that accompanied the samples, the eleven bare silicon samples were from various manufacturers. Table I lists the codes for the samples and the manufacturer of each sample. It also notes if the sample was single or poly-crystalline. The samples had been polished on one side before being sent out for measurements, but no further processing was done. The participants of the study were asked to measure either the lifetime or diffusion length of each of the samples using their standard procedure. Table II shows the experimental conditions used by the groups who measured diffusion length. All the diffusion length measurements were performed using the Surface Photovoltage method (SPV). Table M shows the experimental conditions for the lifetime measurements. All the lifetime measurements were made using the Photoconductance Decay method (PCD) under low level injection. These tables show the diameter of the spot size used during the measurement (the effective sampling area), the locations where measurements were taken, and the number of measurements taken at each location. Table N shows the results of the measurements. The table is divided into diffusion length and lifetime measurements for each sample. The values listed are the average values reported by each group. One of the immediate artifacts seen in the data is the large variation in the lifetime measurements. The values from MIT and Mobil are generally close. However, the measurements from NCSU are typically an order of magnitude lower.

  11. Ultrasonographic measurement of fetal foot length and femur/foot length ratio in second trimester of normal pregnancy tn Korean women

    International Nuclear Information System (INIS)

    Ji, Eun Kyung

    2001-01-01

    The aim of this study was to determine, using prenatal ultrasongraphy, normal fetal foot length and the femur length ratio during the second trimester of a normal pregnancy in Korean women. From May to July 1999, and in September of the same year, 1018 normal Korean singleton pregnancies showing no abnormality on prenatal sonograms were included in this study. The gestational age ranged from 19 to 30 weeks. Femur and foot length were measured by one radiologist. Regression analysis was performed for foot length and gestational age, and the mean value of the femur/foot length ratio and 95th percentile confidence interval of that mean value were calculated. The data obtained was compared with that obtained from caucasians. Foot length correlated with gestational age (r 2 =0.87, ρ value= 0.0001). The regression formula was as follows; Gestational age (days) = 70.98-2.15 X foot length (mm). Mean foot length at each gestational week was not different from the corresponding figure for Cancasians. The mean (±SD) value of the femur/foot length ratio was 0.96 (±0.05) and the 95 th percentile confidence interval of that mean value was 0.96± 0.000301, figures which are significantly lower than those for Caucasians. Fetal foot length during the second trimester of a normal pregnancy in Korean women is a reliable parameter for use in the assessment of gestational age. In our study the fetal foot length was not different from that of caucasians, while the femur/foot length ratio was lower than the value in that group. The nomogram depicted in of this study will serve as a useful adjunct in the screening of chromosomal abnormality or skeletal dysplasia among Koreans

  12. Measuring single-walled carbon nanotube length distributions from diffusional trajectories.

    Science.gov (United States)

    Streit, Jason K; Bachilo, Sergei M; Naumov, Anton V; Khripin, Constantine; Zheng, Ming; Weisman, R Bruce

    2012-09-25

    A new method is demonstrated for measuring the length distributions of dispersed single-walled carbon nanotube (SWCNT) samples by analyzing diffusional motions of many individual nanotubes in parallel. In this method, termed "length analysis by nanotube diffusion" (LAND), video sequences of near-IR fluorescence microscope images showing many semiconducting SWCNTs are recorded and processed by custom image analysis software. This processing locates the individual nanotubes, tracks their translational trajectories, computes the corresponding diffusion coefficients, and converts those values to nanotube lengths. The deduced length values are then compiled into a histogram of lengths present in the sample. By using specific excitation wavelengths and emission filters, this analysis is performed on selected (n,m) structural species. The new LAND method has been found to give distributions in very good agreement with those obtained by conventional AFM analysis of the same samples. Because it is fluorescence-based, LAND monitors only semiconducting, relatively pristine SWCNTs. However, it is less sensitive to artifacts from impurities and bundled nanotubes than AFM or light scattering methods. In addition, samples can be analyzed with less time and operator attention than by AFM. LAND is a promising alternative method for characterizing length distributions of SWCNTs in liquid suspension.

  13. Stability of measures from children's interviews: the effects of time, sample length, and topic.

    Science.gov (United States)

    Heilmann, John; DeBrock, Lindsay; Riley-Tillman, T Chris

    2013-08-01

    The purpose of this study was to examine the reliability of, and sources of variability in, language measures from interviews collected from young school-age children. Two 10-min interviews were collected from 20 at-risk kindergarten children by an examiner using a standardized set of questions. Test-retest reliability coefficients were calculated for 8 language measures. Generalizability theory (G-theory) analyses were completed to document the variability introduced into the measures from the child, session, sample length, and topic. Significant and strong reliability correlation coefficients were observed for most of the language sample measures. The G-theory analyses revealed that most of the variance in the language measures was attributed to the child. Session, sample length, and topic accounted for negligible amounts of variance in most of the language measures. Measures from interviews were reliable across sessions, and the sample length and topic did not have a substantial impact on the reliability of the language measures. Implications regarding the clinical feasibility of language sample analysis for assessment and progress monitoring are discussed.

  14. Direct measurement of the triplet exciton diffusion length in organic semiconductors

    NARCIS (Netherlands)

    Mikhnenko, O.V.; Ruiter, R.; Blom, P.W.M.; Loi, M.A.

    2012-01-01

    We present a new method to measure the triplet exciton diffusion length in organic semiconductors. N,N′-di-[(1-naphthyl)-N,N′-diphenyl]-1,1′-biphenyl)-4,4′-diamine (NPD) has been used as a model system. Triplet excitons are injected into a thin film of NPD by a phosphorescent thin film, which is

  15. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wenzhong; Yi, Ji; Chen, Siyu [Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 (United States); Jiao, Shuliang [Department of Biomedical Engineering, Florida International University, Miami, Florida 33174 (United States); Zhang, Hao F., E-mail: hfzhang@northwestern.edu [Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 and Department of Ophthalmology, Northwestern University, Chicago, Illinois 60611 (United States)

    2015-09-15

    Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.

  16. Measurement of contact angles of microscopic droplets by focal length method.

    Science.gov (United States)

    Geiger, Daniel; Geiger, Kirsten; Neckernuss, Tobias; Marti, Othmar; Amirkhani, Masoud

    2017-08-01

    We present a method to measure contact angles of microscopic droplets with a conventional microscope that possesses a precision focus adjustment stage. The droplets are modeled as spherical caps that act as lenses. Their focal length is determined by measuring the distance from the substrate surface to the level where a sharp image of the aperture stop is observed. The lens diameter is found by edge detection of a microscope image of the microdroplets. The spherical cap model relates the focal length and diameter of such lenses to the contact angle of the used liquid with known refractive index. The measurement procedure was applied to condensed water droplets on a silicon substrate covered by its native oxide layer. The results are found to be in good agreement with conventional, goniometric sessile drop measurements of the advancing contact angle.

  17. Length determination on industrial polymer parts from measurement performed under transient temperature conditions

    DEFF Research Database (Denmark)

    Dalla Costa, Giuseppe; Madruga, Daniel González; De Chiffre, Leonardo

    2016-01-01

    the cooling phase, from 27 °C to 20 °C approximately. The length variation was measured by means of an inductive probe and the temperature with an RTD surface sensor. The frame of the system was composed by elements in Zerodur and Invar to minimize the thermal deformations of the structure. Uniform...... temperature in the part was assumed. The reference length at 20 °C (L20) was calculated with an a posteriori regression of the data from the complete cooling curve. A prediction of L20 was then performed exploiting partial segments of the curve. Several segments with different time spans and starting points...

  18. Measuring the attenuation length of water in the CHIPS-M water Cherenkov detector

    Energy Technology Data Exchange (ETDEWEB)

    Amat, F.; Bizouard, P. [Aix Marseille University Saint-Jerome, 13013 Marseille (France); Bryant, J. [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); Carroll, T.J.; Rijck, S. De [Department of Physics, University of Texas at Austin, Austin, TX 78712 (United States); Germani, S. [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); Joyce, T. [School of Physics and Astronomy, University of Minnesota, Minneapolis, MN 55455 (United States); Kriesten, B. [Department of Physics, College of William & Mary, Williamsburg, VA 23187 (United States); Marshak, M.; Meier, J. [School of Physics and Astronomy, University of Minnesota, Minneapolis, MN 55455 (United States); Nelson, J.K. [Department of Physics, College of William & Mary, Williamsburg, VA 23187 (United States); Perch, A.J.; Pfützner, M.M. [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); Salazar, R. [Department of Physics, University of Texas at Austin, Austin, TX 78712 (United States); Thomas, J., E-mail: jennifer.thomas@ucl.ac.uk [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); Department of Physics, University of Wisconsin, Madison, WI 53706 (United States); Trokan-Tenorio, J. [Department of Physics, University of Wisconsin, Madison, WI 53706 (United States); Vahle, P. [Department of Physics, College of William & Mary, Williamsburg, VA 23187 (United States); Wade, R. [Avenir Consulting, Abingdon, Oxfordshire (United Kingdom); Wendt, C. [Department of Physics, University of Wisconsin, Madison, WI 53706 (United States); Whitehead, L.H. [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); and others

    2017-02-01

    The water at the proposed site of the CHIPS water Cherenkov detector has been studied to measure its attenuation length for Cherenkov light as a function of filtering time. A scaled model of the CHIPS detector filled with water from the Wentworth 2W pit, proposed site of the CHIPS deployment, in conjunction with a 3.2 m vertical column filled with this water, was used to study the transmission of 405 nm laser light. Results consistent with attenuation lengths of up to 100 m were observed for this wavelength with filtration and UV sterilization alone.

  19. Measurement of the diffusion length of thermal neutrons in the beryllium oxide

    International Nuclear Information System (INIS)

    Koechlin, J.C.; Martelly, J.; Duggal, V.P.

    1955-01-01

    The diffusion length of thermal neutrons in the beryllium oxide has been obtained while studying the spatial distribution of the neutrons in a massive parallelepiped of this matter placed before the thermal column of the reactor core of Saclay. The mean density of the beryllium oxide (BeO) is 2,95 gr/cm 3 , the mean density of the massif is 2,92 gr/cm 3 . The value of the diffusion length, deducted of the done measures, is: L = 32,7 ± 0,5 cm (likely gap). Some remarks are formulated about the influence of the spectral distribution of the neutrons flux used. (authors) [fr

  20. Photon path length distributions for cloudy skies – oxygen A-Band measurements and model calculations

    Directory of Open Access Journals (Sweden)

    O. Funk

    Full Text Available This paper addresses the statistics underlying cloudy sky radiative transfer (RT by inspection of the distribution of the path lengths of solar photons. Recent studies indicate that this approach is promising, since it might reveal characteristics about the diffusion process underlying atmospheric radiative transfer (Pfeilsticker, 1999. Moreover, it uses an observable that is directly related to the atmospheric absorption and, therefore, of climatic relevance. However, these studies are based largely on the accuracy of the measurement of the photon path length distribution (PPD. This paper presents a refined analysis method based on high resolution spectroscopy of the oxygen A-band. The method is validated by Monte Carlo simulation atmospheric spectra. Additionally, a new method to measure the effective optical thickness of cloud layers, based on fitting the measured differential transmissions with a 1-dimensional (discrete ordinate RT model, is presented. These methods are applied to measurements conducted during the cloud radar inter-comparison campaign CLARE’98, which supplied detailed cloud structure information, required for the further analysis. For some exemplary cases, measured path length distributions and optical thicknesses are presented and backed by detailed RT model calculations. For all cases, reasonable PPDs can be retrieved and the effects of the vertical cloud structure are found. The inferred cloud optical thicknesses are in agreement with liquid water path measurements.

    Key words. Meteorology and atmospheric dynamics (radiative processes; instruments and techniques

  1. Photon path length distributions for cloudy skies – oxygen A-Band measurements and model calculations

    Directory of Open Access Journals (Sweden)

    O. Funk

    2003-03-01

    Full Text Available This paper addresses the statistics underlying cloudy sky radiative transfer (RT by inspection of the distribution of the path lengths of solar photons. Recent studies indicate that this approach is promising, since it might reveal characteristics about the diffusion process underlying atmospheric radiative transfer (Pfeilsticker, 1999. Moreover, it uses an observable that is directly related to the atmospheric absorption and, therefore, of climatic relevance. However, these studies are based largely on the accuracy of the measurement of the photon path length distribution (PPD. This paper presents a refined analysis method based on high resolution spectroscopy of the oxygen A-band. The method is validated by Monte Carlo simulation atmospheric spectra. Additionally, a new method to measure the effective optical thickness of cloud layers, based on fitting the measured differential transmissions with a 1-dimensional (discrete ordinate RT model, is presented. These methods are applied to measurements conducted during the cloud radar inter-comparison campaign CLARE’98, which supplied detailed cloud structure information, required for the further analysis. For some exemplary cases, measured path length distributions and optical thicknesses are presented and backed by detailed RT model calculations. For all cases, reasonable PPDs can be retrieved and the effects of the vertical cloud structure are found. The inferred cloud optical thicknesses are in agreement with liquid water path measurements. Key words. Meteorology and atmospheric dynamics (radiative processes; instruments and techniques

  2. Lifetime and diffusion length measurements on silicon material and solar cells. [Intentionally doped with impurities

    Energy Technology Data Exchange (ETDEWEB)

    Othmer, S.; Chen, S.C.

    1977-01-01

    Experimental methods were evaluated for the determination of lifetime and diffusion length in silicon intentionally doped with potentially lifetime-degrading impurities found in metallurgical grade silicon, impurities which may be residual in low-cost silicon intended for use in terrestrial flat-plat arrays. Results obtained by these methods were compared for mutual consistency. Lifetime measurements were made using a steady-state photoconductivity method, which was compared with a photoconductivity decay technique. Diffusion length determinations were made using short-circuit current measurements under penetrating illumination. This method was compared with a direct measurement of diffusion length using a scanning electron microscope. Mutual consistency among all experimental methods was verified, but steady-state photoconductivity was found preferable to photoconductivity decay at short lifetimes and in the presence of traps. The effects of a number of impurities on lifetime in bulk material, and on diffusion length in cells fabricated from this material, were determined. Results were compared with those obtained by others on the same material and devices using different techniques. General agreement was found in terms of the hierarchy of impurities which degrade the lifetime.

  3. Air method measurements of apple vessel length distributions with improved apparatus and theory.

    Science.gov (United States)

    Cohen, Shabtai; Bennink, John; Tyree, Mel

    2003-08-01

    Studies showing that rootstock dwarfing potential is related to plant hydraulic conductance led to the hypothesis that xylem properties are also related. Vessel length distribution and other properties of apple wood from a series of varieties were measured using the 'air method' in order to test this hypothesis. Apparatus was built to measure and monitor conductivity to air of fresh wood segments of different lengths. Theory for determining vessel length distribution was improved to give a single parameter uni-modal vessel length probability density function. The function, derived by combining the exponential extinction (with extinction coefficient k) of wood conductivity to air (C) as wood length (x) increases (i.e. C=Co exp (-kx)) with the differential double difference formula, is Px=xxk2 exp (-kx), where Px is the fraction of vessels of length x. The main parameter of the distribution, k, was found to be the inverse of the mode of the distribution, i.e. the most common vessel length, Lo. Lo for ten apple rootstock and scion varieties varied from 5.6+/-0.1 cm (+/-SE) for MM.111 to 9.0+/-1.0 for Prunifolia (P <0.05). Average maximum vessel length was approximately 50 cm, and differences were not significant. Effective vessel radii ranged from 14 for Prunifolia to 24.3+/-0.7 micro m for M.26, with standard errors less than 12% of the mean. Specific conductivity of a 15 cm wood segment ranged from 2x109-4) to 1.6+/-0.2x10(-2) dm3 s(-1) kPa(-1) m(-1) for maruba and M.26, respectively, with standard errors up to 63% of the mean. Vessel density at the air entry point ranged from 18+/-3 to 42+/-6 vessels mm-2 for M.26 and MM.106, respectively, with standard errors as high as 89% of the mean. It was concluded that there is no general relationship between the wood properties investigated and rootstock size class, and that plasticity increases from vessel lengths to radii to specific conductivity and vessel densities.

  4. Ex vivo radiographic tooth length measurements with the reference sphere method (RSM).

    Science.gov (United States)

    Roeder, Felix; Brüllmann, Dan; d'Hoedt, Bernd; Schulze, Ralf

    2010-12-01

    A reference-based radiographic "reference sphere method" (RSM) for accurate length measurements in (dental) projection radiographs for the assessment of tooth length in dry human mandible sections is evaluated. RSM determines the depth coordinates of reference spheres placed in the object plane from the elliptical distortion of their shadows. Two segments (one canine and one molar) of dry human mandibles were exposed 95 times at different angulations (0-40°) on a dental charge-coupled device receptor. Three steel spheres (diameters d (1) = 2.00 mm, d (2) = 3.00 mm) were attached roughly coplanar with the tooth's main axis. Radiographs were assessed once by visual inspection plus manual landmark identification with a mouse-driven cursor. The results were compared to the true tooth length assessed after extraction and to a conventional method (C), i.e., the rule of proportion based on magnification of the sphere shadows. Mean relative length error was 2.28% (d (1)) and 0.46% (d (2)) for RSM and -13.58% (d (1)) and -9.90% (d (2)) for C. For both methods, length errors were significantly (p correction of objects coplanar with the reference spheres. Remaining errors are mainly due to incorrect landmark definition. In our setup, these were exaggerated by the visual/manual image-evaluation process. Automated image analysis has been shown for similar tasks to minimize these errors considerably.

  5. The influence of humidity on accuracy length measurement on polymer parts

    DEFF Research Database (Denmark)

    Madruga, Daniel González; Alexiou, A.; Dalla Costa, Giuseppe

    2016-01-01

    The work deals with an experimental study of the influence of humidity on accurate length measurements on ABS parts. Polymer parts absorb water from the ambient until they reach hygroscopic equilibrium. Water content causes an expansion of the polymer part. The relationship between the water...... content and this expansion has been barely studied, especially from a metrology point of view including its contribution to the measurement uncertainty. The experimental set-up includes a humidity chamber, an invar fixture with 8 inductive probes and a scale. The humidity chamber was used to create...... parts were measured at 5 levels of relative humidity from 50 %RH to 90 %RH, and constant temperature, 20 ±0.2˚C. Water content equilibrium with the ambient was achieved at each level by acclimatization of the parts for 24 hours. An average length variation over the humidity range of 15 μm was found...

  6. L-shaped caliper for limb length measurement during total hip arthroplasty.

    Science.gov (United States)

    Shiramizu, K; Naito, M; Shitama, T; Nakamura, Y; Shitama, H

    2004-09-01

    The existing methods of assessing limb lengthening during total hip arthroplasty (THA) are prone to error because the measurements are not parallel to the limb lengthening axis. In order to address this, we designed a caliper to estimate limb lengthening during THA and evaluated its accuracy compared with our previous device, the straight caliper. Limb lengths were measured in 100 patients. The L-shaped caliper was used in 50 cases and the straight caliper in 50. The correlation between intra-operative and post-operative radiographic measurements was significantly improved using the L-shaped device (p < 0.0001, r = 0.934). This method was extremely accurate in predicting changes in limb length due to surgery.

  7. Two- and three-dimensional CT measurements of urinary calculi length and width: a comparative study.

    Science.gov (United States)

    Lidén, Mats; Thunberg, Per; Broxvall, Mathias; Geijer, Håkan

    2015-04-01

    The standard imaging procedure for a patient presenting with renal colic is unenhanced computed tomography (CT). The CT measured size has a close correlation to the estimated prognosis for spontaneous passage of a ureteral calculus. Size estimations of urinary calculi in CT images are still based on two-dimensional (2D) reformats. To develop and validate a calculus oriented three-dimensional (3D) method for measuring the length and width of urinary calculi and to compare the calculus oriented measurements of the length and width with corresponding 2D measurements obtained in axial and coronal reformats. Fifty unenhanced CT examinations demonstrating urinary calculi were included. A 3D symmetric segmentation algorithm was validated against reader size estimations. The calculus oriented size from the segmentation was then compared to the estimated size in axial and coronal 2D reformats. The validation showed 0.1 ± 0.7 mm agreement against reference measure. There was a 0.4 mm median bias for 3D estimated calculus length compared to 2D (P calculus in axial and coronal reformats becomes underestimated compared to 3D if its orientation is not aligned to the image planes. Future studies aiming to correlate calculus size with patient outcome should use a calculus oriented size estimation. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  8. Is socioeconomic status associated with biological aging as measured by telomere length?

    Science.gov (United States)

    Robertson, Tony; Batty, G David; Der, Geoff; Fenton, Candida; Shiels, Paul G; Benzeval, Michaela

    2013-01-01

    It has been hypothesized that one way in which lower socioeconomic status (SES) affects health is by increasing the rate of biological aging. A widely used marker of biological aging is telomere length. Telomeres are structures at the ends of chromosomes that erode with increasing cell proliferation and genetic damage. We aimed to identify, through systematic review and meta-analysis, whether lower SES (greater deprivation) is associated with shorter telomeres. Thirty-one articles, including 29 study populations, were identified. We conducted 3 meta-analyses to compare the telomere lengths of persons of high and low SES with regard to contemporaneous SES (12 study populations from 10 individual articles), education (15 study populations from 14 articles), and childhood SES (2 study populations from 2 articles). For education, there was a significant difference in telomere length between persons of high and low SES in a random-effects model (standardized mean difference (SMD) = 0.060, 95% confidence interval (CI): 0.002, 0.118; P = 0.042), although a range of sensitivity analyses weakened this association. There was no evidence for an association between telomere length and contemporaneous SES (SMD = 0.104, 95% CI: -0.027, 0.236; P = 0.119) or childhood SES (SMD = -0.037, 95% CI: -0.143, 0.069; P = 0.491). These results suggest weak evidence for an association between SES (as measured by education) and biological aging (as measured by telomere length), although there was a lack of consistent findings across the SES measures investigated here. © The Author 2012. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health.

  9. Core Length and Spray Width Measurements in Shear Coaxial Rocket Injectors from X-ray Radiography Measurements

    Science.gov (United States)

    2015-05-01

    Rocket Injectors from X-ray Radiography Measurements 5a. CONTRACT NUMBER In-House 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) M. D...behavior. To overcome the problems of multiple scattering, the near-injector region was studied using x-ray radiography at Argonne National Laboratory’s...and understand more clearly what this term means. Three methods are explored to measure core length from x-ray radiography data and are compared to

  10. Core Length and Spray Width Measurements in Shear Coaxial Injectors from X-ray Radiography Measurements (Briefing Charts)

    Science.gov (United States)

    2015-04-01

    Injectors from X- ray Radiography Measurements 5a. CONTRACT NUMBER In-House 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d...behavior. To overcome the problems of multiple scattering, the near-injector region was studied using x-ray radiography at Argonne National...length” and understand more clearly what this term means. Three methods are explored to measure core length from x-ray radiography data and are

  11. Analysis of impedance measurements of a suspension of microcapsules using a variable length impedance measurement cell

    Directory of Open Access Journals (Sweden)

    Dejan Krizaj

    2012-10-01

    Full Text Available Electrical impedance measurements of the suspensions have to take into account the double layer impedance that is due to a very thin charged layer formed at the electrode-electrolite interface. A dedicated measuring cell that enables variation of the distance between the electrodes was developed for investigation of electrical properties of suspensions using two electrode impedance measurements. By varying the distance between the electrodes it is possible to separate the double layer and the suspension impedance from the measured data. From measured and extracted impedances electrical lumped models have been developed. The error of non inclusion of the double layer impedance has been analyzed. The error depends on the frequency of the measurements as well as on the distance between the electrodes.

  12. Dynamic Length Metrology (DLM) for measurements with sub-micrometre uncertainty in a production environment

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Hansen, Hans Nørgaard; Hattel, Jesper Henri

    2016-01-01

    by mathematical or numerical modelling of the thermo-mechanical effects. It is hereby possible concurrently to predict condition-specific material properties as well as part dimensions at any point, time, temperature, humidity, etc. Knowing all systematic errors and influencing factors, and their combined effect......, on a given length, it is possible to calculate the corrected length at 20°C, zero measuring force, etc. An estimation of the measurement uncertainty U can be obtained following the guidelines of the GUM, dimensional values and their uncertainties being the final result of the analysis. Preliminary...... investigations have indicated that the approach is viable, either using analytical modelling or FEM. An expanded uncertainty (k=2) lower than 0.4 μm was achieved using a steel gauge block as workpiece....

  13. Non-dispersive method for measuring longitudinal neutron coherence length using high frequency cold neutron pulser

    International Nuclear Information System (INIS)

    Kawai, T.; Tasaki, S.; Ebisawa, T.; Hino, M.; Yamazaki, D.; Achiwa, N.

    1999-01-01

    Complete text of publication follows. A non-dispersive method is proposed for measuring the longitudinal coherence length of a neutron using a high frequency cold neutron pulser (hf-CNP) placed between two multilayer spin splitters (MSS) which composes the cold neutron spin interferometer. Two spin eigenstates of a neutron polarized x-y plane are split non-dispersively and longitudinally in time by the hf-CNP which could reflect two components alternatively in time. The reduction of the visibility of interference fringes after being superposed by the second MSS is measured as a function of the frequency of the pulser by TOF method. From the zero visibility point obtained by extrapolation one could obtain the longitudinal coherence length of the neutron. (author)

  14. Influence of DNA extraction methods on relative telomere length measurements and its impact on epidemiological studies.

    Science.gov (United States)

    Raschenberger, Julia; Lamina, Claudia; Haun, Margot; Kollerits, Barbara; Coassin, Stefan; Boes, Eva; Kedenko, Ludmilla; Köttgen, Anna; Kronenberg, Florian

    2016-05-03

    Measurement of telomere length is widely used in epidemiologic studies. Insufficient standardization of the measurements processes has, however, complicated the comparison of results between studies. We aimed to investigate whether DNA extraction methods have an influence on measured values of relative telomere length (RTL) and whether this has consequences for epidemiological studies. We performed four experiments with RTL measurement in quadruplicate by qPCR using DNA extracted with different methods: 1) a standardized validation experiment including three extraction methods (magnetic-particle-method EZ1, salting-out-method INV, phenol-chloroform-isoamyl-alcohol PCI) each in the same 20 samples demonstrated pronounced differences in RTL with lowest values with EZ1 followed by INV and PCI-isolated DNA; 2) a comparison of 307 samples from an epidemiological study showing EZ1-measurements 40% lower than INV-measurements; 3) a matching-approach of two similar non-diseased control groups including 143 pairs of subjects revealed significantly shorter RTL in EZ1 than INV-extracted DNA (0.844 ± 0.157 vs. 1.357 ± 0.242); 4) an association analysis of RTL with prevalent cardiovascular disease detected a stronger association with INV than with EZ1-extracted DNA. In summary, DNA extraction methods have a pronounced influence on the measured RTL-values. This might result in spurious or lost associations in epidemiological studies under certain circumstances.

  15. Fiber length measurement from the determination of juvenile wood in Eucalyptus citriodora

    OpenAIRE

    Calonego, Fred Willians [UNESP; Severo, Elias Taylor Durgante [UNESP; Assi, Priscila Paula [UNESP

    2005-01-01

    The juvenile wood has peculiar characteristics from the anatomical structure and physical-mechanical properties, considering these aspects the knowledge of the wood is essential for wood adequate utilization. The aim of this work was to determinate the zone of juvenile wood of pith-bark direction in Eucalyptus citriodora. The juvenile and mature wood zones were determined across fiber length measurement in various height in the tree stem. Results showed that juvenile wood zone occurs approxim...

  16. Interpretation of Core Length in Shear Coaxial Rocket Injectors from X-ray Radiography Measurements

    Science.gov (United States)

    2014-06-01

    technique , X- ray radiography , to the well-studied problem of core length of shear coaxial jets is an important step in understanding the strengths...role, as is evident in Fig. 8a for the SC1. Unfortunately the X-ray radiography technique cannot distinguish between intact liquid in the jet and...Shear Coaxial Rocket Injectors from X-ray Radiography Measurements 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT

  17. Cervical Length & Leading Placental Edge to Internal OS Measurements - TA vs TV

    DEFF Research Database (Denmark)

    Westerway, Sue Campbell; Pedersen, Lars Henning; Hyett, Jon

    Brief Description of the Purpose of the Study: To compare cervical length/leading placental edge from the internal cervical os measurements obtained by both transabdominal (TA) and transvaginal (TV) approach and to assess intra / inter-observer variation for these measurements. Methods: Cross......, both overall and stratified by gestation. Test characteristics were calculated for cervix,25mm. On twenty of the above studies, two observers measured each of the param- eters at least twice. Intra / inter-observer error was the mean deviation calculated as a percentage of the mean measurement. Main...... Results: Overall, TA measurements of both cervix and placental edge position were statistically different from measure- ments obtained TV. In second trimester, the TA cervix estimate was 2.7 mm , (95% CI 1.8-3.6) TV estimate. .24 weeks gestation, the difference between the two methods for cervix...

  18. The accuracy of the radiographic method in root canal length measurement

    International Nuclear Information System (INIS)

    Jo, Eun Young; Park, Chang Seo

    1998-01-01

    For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems (p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems (p>0.05). 2. In Digora system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques (p 0.05). In conclusion, the determination of the root canal length by using the

  19. The accuracy of the radiographic method in root canal length measurement

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Eun Young; Park, Chang Seo [Dept. of Dental Radiology, College of Dentistry, Yonsei University, Seoul (Korea, Republic of)

    1998-08-15

    For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems (p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems (p>0.05). 2. In Digora system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques (p<0.05). Also, 3. In Digora system and the standard periapical radiographs

  20. Effect of length of measurement period on accuracy of predicted annual heating energy consumption of buildings

    International Nuclear Information System (INIS)

    Cho, Sung-Hwan; Kim, Won-Tae; Tae, Choon-Soeb; Zaheeruddin, M.

    2004-01-01

    This study examined the temperature dependent regression models of energy consumption as a function of the length of the measurement period. The methodology applied was to construct linear regression models of daily energy consumption from 1 day to 3 months data sets and compare the annual heating energy consumption predicted by these models with actual annual heating energy consumption. A commercial building in Daejon was selected, and the energy consumption was measured over a heating season. The results from the investigation show that the predicted energy consumption based on 1 day of measurements to build the regression model could lead to errors of 100% or more. The prediction error decreased to 30% when 1 week of data was used to build the regression model. Likewise, the regression model based on 3 months of measured data predicted the annual energy consumption within 6% of the measured energy consumption. These analyses show that the length of the measurement period has a significant impact on the accuracy of the predicted annual energy consumption of buildings

  1. Is walking a random walk? Evidence for long-range correlations in stride interval of human gait

    Science.gov (United States)

    Hausdorff, Jeffrey M.; Peng, C.-K.; Ladin, Zvi; Wei, Jeanne Y.; Goldberger, Ary L.

    1995-01-01

    Complex fluctuation of unknown origin appear in the normal gait pattern. These fluctuations might be described as being (1) uncorrelated white noise, (2) short-range correlations, or (3) long-range correlations with power-law scaling. To test these possibilities, the stride interval of 10 healthy young men was measured as they walked for 9 min at their usual rate. From these time series we calculated scaling indexes by using a modified random walk analysis and power spectral analysis. Both indexes indicated the presence of long-range self-similar correlations extending over hundreds of steps; the stride interval at any time depended on the stride interval at remote previous times, and this dependence decayed in a scale-free (fractallike) power-law fashion. These scaling indexes were significantly different from those obtained after random shuffling of the original time series, indicating the importance of the sequential ordering of the stride interval. We demonstrate that conventional models of gait generation fail to reproduce the observed scaling behavior and introduce a new type of central pattern generator model that sucessfully accounts for the experimentally observed long-range correlations.

  2. Comparison of lifts versus tape measure in determining leg length discrepancy.

    Science.gov (United States)

    Badii, Maziar; Wade, A Nicole; Collins, David R; Nicolaou, Savvakis; Kobza, B Jacek; Kopec, Jacek A

    2014-08-01

    To evaluate the validity (accuracy) and reliability of 2 commonly used clinical methods, 1 indirect (lifts) and 1 direct (tape measure), for assessment of leg length discrepancy (LLD) in comparison to radiograph. Twenty subjects suspected of having LLD participated in this study. Two clinical methods, 1 direct using a tape measure and 1 indirect using lifts, were standardized and carried out by 4 examiners. Difference in height of the femoral heads on standing pelvic radiograph was measured and served as the gold standard. The intraclass correlation coefficient assessing interobserver reliability was 0.737 for lifts and 0.477 for tape measure. The remainder of the analysis is based on the average of the measurements by the 4 examiners. Pearson correlation coefficients were 0.93 for the lifts and 0.75 for the tape measure method. Paired sample t tests showed difference in means of 2 mm (p = 0.051) for lifts and -5 mm (p = 0.007) for tape measure compared with radiograph. Sensitivity and specificity were 55% and 89% for lifts and 45% and 56% for tape measure, respectively, using > 5 mm as the definition for LLD. The wrong leg was identified as being shorter in 1 out of 20 subjects using lifts versus 7 out of 20 using tape measure. The indirect standing method of LLD measurement using lifts had superior validity, interobserver reliability, and specificity in comparison with radiograph over the direct supine method using tape measure. Both clinical methods underestimated LLD compared with radiograph.

  3. Reliability of length measurements collected by community nurses and health volunteers in rural growth monitoring and promotion services.

    Science.gov (United States)

    Laar, Matilda E; Marquis, Grace S; Lartey, Anna; Gray-Donald, Katherine

    2018-02-17

    Length measurements are important in growth, monitoring and promotion (GMP) for the surveillance of a child's weight-for-length and length-for-age. These two indices provide an indication of a child's risk of becoming wasted or stunted, and are more informative about a child's growth than the widely used weight-for-age index (underweight). Although the introduction of length measurements in GMP is recommended by the World Health Organization, concerns about the reliability of length measurements collected in rural outreach settings have been expressed by stakeholders. Our aim was to describe the reliability and challenges associated with community health personnel measuring length for rural outreach GMP activities. Two reliability studies (A and B), using 10 children less than 24 months each, were conducted in the GMP services of a rural district in Ghana. Fifteen nurses and 15 health volunteers (HV) with no prior experience in length measurements were trained. Intra- and inter-observer technical error of measurement (TEM), average bias from expert anthropometrist, and coefficient of reliability (R) of length measurements were assessed and compared across sessions. Observations and interviews were used to understand the ability and experiences of health personnel with measuring length at outreach GMP. Inter-observer TEM was larger than intra-observer TEM for both nurses and HV at both sessions and was unacceptably (compared to error standards) high in both groups at both time points. Average biases from expert's measurements were within acceptable limits, however, both groups tended to underestimate length measurements. The R for lengths collected by nurses (92.3%) was higher at session B compared to that of HV (87.5%). Length measurements taken by nurses and HV, and those taken by an experienced anthropometrist at GMP sessions were of moderate agreement (kappa = 0.53, p reliability of length measurements improved after two refresher trainings for nurses but

  4. Round-Trip System Available to Measure Path Length Variation in Korea VLBI System for Geodesy

    Science.gov (United States)

    Oh, Hongjong; Kondo, Tetsuro; Lee, Jinoo; Kim, Tuhwan; Kim, Myungho; Kim, Suchul; Park, Jinsik; Ju, Hyunhee

    2010-01-01

    The construction project of Korea Geodetic VLBI officially started in October 2008. The construction of all systems will be completed by the end of 2011. The project was named Korea VLBI system for Geodesy (KVG), and its main purpose is to maintain the Korea Geodetic Datum. In case of the KVG system, an observation room with an H-maser frequency standard is located in a building separated from the antenna by several tens of meters. Therefore KVG system will adopt a so-called round-trip system to transmit reference signals to the antenna with reduction of the effect of path length variations. KVG s round-trip system is designed not only to use either metal or optical fiber cables, but also to measure path length variations directly. We present this unique round trip system for KVG.

  5. A set-up to measure the optical attenuation length of scintillating fibres

    CERN Document Server

    Alfieri, C; Joram, C

    2015-01-01

    The optical attenuation length of a scintillating fibre characterizes the quality of light transport through the fibre. It relates directly to the quantity of detectable light at the readout end of the fibre. An optical bench has been constructed, which allows excitation of the fibre at various distances from the photodetector. Depending on the choice of the photodetector – Si-PIN photodiode or grating spectrometer – the attenuation length is measured as weighted average over the sensitivity of the photodetector or as a spectral distribution. A few examples illustrate its operation and performance. The set-up serves for fibre optimisation in the R&D phase and is expected to be used for systematic checks during the series production phase of the LHCb SciFi tracker project.

  6. Measurement of the $\\pi K$ atom lifetime and the $\\pi K$ scattering length

    CERN Document Server

    Adeva, B.; The PS212 collaboration; Allkofer, Y.; Amsler, C.; Anania, A.; Aogaki, S.; Benelli, A.; Brekhovskikh, V.; Cechak, T.; Chiba, M.; Chliapnikov, P.; Drijard, D.; Dudarev, A.; Dumitriu, D.; Federicova, P.; Fluerasu, D.; Gorin, A.; Gorchakov, O.; Gritsay, K.; Guaraldo, C.; Gugiu, M.; Hansroul, M.; Hons, Z.; Horikawa, S.; Iwashita, Y.; Karpukhin, V.; Kluson, J.; Kobayashi, M.; Kruglov, V.; Kruglova, L.; Kulikov, A.; Kulish, E.; Kuptsov, A.; Lamberto, A.; Lanaro, A.; Lednicky, R.; Marinas, C.; Martincik, J.; Nemenov, L.; Nikitin, M.; Okada, K.; Olchevskii, V.; Pentia, M.; Penzo, A.; Plo, M.; Prusa, P.; Rappazzo, G.; Romero Vidal, A.; Ryazantsev, A.; Rykalin, V.; Saborido, J.; Schacher, J.; Sidorov, A.; Smolik, J.; Takeutchi, F.; Tauscher, L.; Trojek, T.; Trusov, S.; Urban, T.; Vrba, T.; Yazkov, V.; Yoshimura, Y.; Zhabitsky, M.; Zrelov, P.

    2017-09-19

    After having announced the statistically significant observation (5.6~$\\sigma$) of the new exotic $\\pi K$ atom, the DIRAC experiment at the CERN proton synchrotron presents the measurement of the corresponding atom lifetime, based on the full $\\pi K$ data sample: $\\tau = (5.5^{+5.0}_{-2.8}) \\cdot 10^{-15}s$. By means of a precise relation ($<1\\%$) between atom lifetime and scattering length, the following value for the S-wave isospin-odd $\\pi K$ scattering length $a_0^{-}~=~\\frac{1}{3}(a_{1/2}-a_{3/2})$ has been derived: $\\left|a_0^-\\right| = (0.072^{+0.031}_{-0.020}) M_{\\pi}^{-1}$.

  7. Interferometer with Continuously Varying Path Length Measured in Wavelengths to the Reference Mirror

    Science.gov (United States)

    Ohara, Tetsuo (Inventor)

    2016-01-01

    An interferometer in which the path length of the reference beam, measured in wavelengths, is continuously changing in sinusoidal fashion and the interference signal created by combining the measurement beam and the reference beam is processed in real time to obtain the physical distance along the measurement beam between the measured surface and a spatial reference frame such as the beam splitter. The processing involves analyzing the Fourier series of the intensity signal at one or more optical detectors in real time and using the time-domain multi-frequency harmonic signals to extract the phase information independently at each pixel position of one or more optical detectors and converting the phase information to distance information.

  8. Measurement report on the LHC injection kicker ripple denition and maximum pulse length (MD 1268)

    CERN Document Server

    Bartmann, Wolfgang; Kotzian, Gerd; Stoel, Linda; Velotti, Francesco Maria; Vlachodimitropoulos, Vasileios; Wiesner, Christoph; CERN. Geneva. ATS Department

    2016-01-01

    The present LHC lling scheme uses a batch spacing which corresponds to the design report specication of the injection kicker rise time. A reduction of the batch spacing can be directly used to increase luminosity without detrimental eect on beam stability. Therefore, measurements were performed to understand if a tighter batch spacing would lead to increased injection oscillations of a the rst and last bunches of a bunch train and eventually also a growth of the transverse emittance. The results of theses measurement were used to dene the minimum possible batch spacing for an acceptable emittance growth. Another measurement was performed to test if a batch consisting of 320 bunches can be injected instead of the nominal 288 bunch trains. This bunch train is dierently produced in the LHC injectors and features an optimum between beam stability and luminosity gain. The pulse length of the injection kicker was measured to ensure the full batch can be injected at once.

  9. Comparison of Echo 7 field line length measurements to magnetospheric model predictions

    International Nuclear Information System (INIS)

    Nemzek, R.J.; Winckler, J.R.; Malcolm, P.R.

    1992-01-01

    The Echo 7 sounding rocket experiment injected electron beams on central tail field lines near L = 6.5. Numerous injections returned to the payload as conjugate echoes after mirroring in the southern hemisphere. The authors compare field line lengths calculated from measured conjugate echo bounce times and energies to predictions made by integrating electron trajectories through various magnetospheric models: the Olson-Pfitzer Quiet and Dynamic models and the Tsyganenko-Usmanov model. Although Kp at launch was 3-, quiet time magnetic models est fit the echo measurements. Geosynchronous satellite magnetometer measurements near the Echo 7 field lies during the flight were best modeled by the Olson-Pfitzer Dynamic Model and the Tsyganenko-Usmanov model for Kp = 3. The discrepancy between the models that best fit the Echo 7 data and those that fit the satellite data was most likely due to uncertainties in the small-scale configuration of the magnetospheric models. The field line length measured by the conjugate echoes showed some temporal variation in the magnetic field, also indicated by the satellite magnetometers. This demonstrates the utility an Echo-style experiment could have in substorm studies

  10. Measurement of cochlear length using the 'A' value for cochlea basal diameter: A feasibility study.

    Science.gov (United States)

    Deep, Nicholas L; Howard, Brittany E; Holbert, Sarah O; Hoxworth, Joseph M; Barrs, David M

    2017-07-01

    To determine whether the cochlea basal diameter (A value) measurement can be consistently and precisely obtained from high-resolution temporal bone imaging for use in cochlear length estimation. A feasibility study at a tertiary referral center was performed using the temporal bone CTs of 40 consecutive patients. The distance from the round window to the lateral wall was measured for each cochlea by two independent reviewers, a neuroradiologist and an otolaryngologist. The interrater reliability was calculated using the intraclass correlation coefficient (ICC) and the Bland-Altman plot. Forty patients (19 males, 21 females) for a total of 80 cochleae were included. Interrater reliability on the same ear had a high level of agreement by both the ICC and the Bland-Altman plot. ICCs were 0.90 (95% CI: 0.82, 0.94) for the left ear and 0.96 (95% CI: 0.92, 0.98) for the right ear. Bland-Altman plot confirmed interrater reliability with all 96% of measurements falling within the 95% limits of agreement. Measurement between the round window and lateral cochlear wall can be consistently and reliably obtained from high-resolution temporal bone CT scans. Thus, it is feasible to utilize this method to estimate the cochlear length of patients undergoing cochlear implantation.

  11. In Vivo Sarcomere Length Measurement in Whole Muscles during Passive Stretch and Twitch Contractions.

    Science.gov (United States)

    Young, Kevin W; Kuo, Bill P-P; O'Connor, Shawn M; Radic, Stojan; Lieber, Richard L

    2017-02-28

    Muscle force is dictated by micrometer-scale contractile machines called sarcomeres. Whole-muscle force drops from peak force production to zero with just a few micrometers of sarcomere length change. No current technology is able to capture adequate dynamic sarcomere data in vivo, and thus we lack fundamental data needed to understand human movement and movement disorders. Methods such as diffraction, endoscopy, and optical coherence tomography have been applied to muscle but are prohibitively invasive, sensitive to motion artifact, and/or imprecise. Here, we report dynamic sarcomere length measurement in vivo using a combination of our recently validated resonant reflection spectroscopy method combined with optical frequency domain interferometry. Using a 250-μm-wide fiber optic probe, we captured nanometer sarcomere length changes from thousands of sarcomeres on the sub-millisecond timescale during whole-muscle stretch and twitch contraction. We believe that this demonstrates the first large-scale sensing of sarcomere dynamics in vivo, which is a necessary first step to understand movement disorders and to create patient-specific surgical interventions and rehabilitation. Published by Elsevier Inc.

  12. Comparison between Conventional Blind Embryo Transfer and Embryo Transfer Based on Previously Measured Uterine Length

    Directory of Open Access Journals (Sweden)

    Nasrin Saharkhiz

    2014-11-01

    Full Text Available Background: Embryo transfer (ET is one of the most important steps in assisted reproductive technology (ART cycles and affected by many factors namely the depth of embryo deposition in uterus. In this study, the outcomes of intracytoplasmic sperm injection (ICSI cycles after blind embryo transfer and embryo transfer based on previously measured uterine length using vaginal ultrasound were compared. Materials and Methods: This prospective randomised clinical trial included one hundred and forty non-donor fresh embryo transfers during January 2010 to June 2011. In group I, ET was performed using conventional (blind method at 5-6cm from the external os, and in group II, ET was done at a depth of 1-1.5 cm from the uterine fundus based on previously measured uterine length using vaginal sonography. Appropriate statistical analysis was performed using Student’s t test and Chi-square or Fisher’s exact test. The software that we used was PASW statistics version 18. A p value <0.05 was considered statistically significant. Results: Chemical pregnancy rate was 28.7% in group I and 42.1% in group II, while the difference was not statistically significant (p=0.105. Clinical pregnancy, ongoing pregnancy and implantation rates for group I were 21.2%, 17.7%, and 12.8%, while for group II were 33.9%, 33.9%, and 22.1, respectively. In group I and group II, abortion rates were 34.7% and 0%, respectively, indicating a statistically significant difference (p<0.005. No ectopic pregnancy occurred in two groups. Conclusion: The use of uterine length measurement during treatment cycle in order to place embryos at depth of 1-1.5cm from fundus significantly increases clinical and ongoing pregnancy and implantation rates, while leads to a decrease in abortion rate (Registration Number: IRCT2014032512494N1.

  13. Effects of energy chirp on bunch length measurement in linear accelerator beams

    Science.gov (United States)

    Sabato, L.; Arpaia, P.; Giribono, A.; Liccardo, A.; Mostacci, A.; Palumbo, L.; Vaccarezza, C.; Variola, A.

    2017-08-01

    The effects of assumptions about bunch properties on the accuracy of the measurement method of the bunch length based on radio frequency deflectors (RFDs) in electron linear accelerators (LINACs) are investigated. In particular, when the electron bunch at the RFD has a non-negligible energy chirp (i.e. a correlation between the longitudinal positions and energies of the particle), the measurement is affected by a deterministic intrinsic error, which is directly related to the RFD phase offset. A case study on this effect in the electron LINAC of a gamma beam source at the Extreme Light Infrastructure-Nuclear Physics (ELI-NP) is reported. The relative error is estimated by using an electron generation and tracking (ELEGANT) code to define the reference measurements of the bunch length. The relative error is proved to increase linearly with the RFD phase offset. In particular, for an offset of {{7}\\circ} , corresponding to a vertical centroid offset at a screen of about 1 mm, the relative error is 4.5%.

  14. Diffusion length measurement using the scanning electron microscope. [for silicon solar cell

    Science.gov (United States)

    Weizer, V. G.

    1975-01-01

    The present work describes a measuring technique employing the scanning electron microscope in which values of the true bulk diffusion length are obtained. It is shown that surface recombination effects can be eliminated through application of highly doped surface field layers. The effects of high injection level and low-high junction current generation are investigated. Results obtained with this technique are compared to those obtained by a penetrating radiation (X-ray) method, and a close agreement is found. The SEM technique is limited to cells that contain a back surface field layer.

  15. Determination of {pi}{pi} scattering lengths from measurement of {pi}{sup +{pi}-} atom lifetime

    Energy Technology Data Exchange (ETDEWEB)

    Adeva, B. [Santiago de Compostela University (Spain); Afanasyev, L. [JINR Dubna (Russian Federation); Benayoun, M. [LPNHE des Universites Paris VI/VII, IN2P3-CNRS (France); Benelli, A. [Zurich University (Switzerland); Berka, Z. [Czech Technical University in Prague, Prague (Czech Republic); Brekhovskikh, V. [IHEP Protvino (Russian Federation); Caragheorgheopol, G. [IFIN-HH, National Institute for Physics and Nuclear Engineering, Bucharest (Romania); Cechak, T. [Czech Technical University in Prague, Prague (Czech Republic); Chiba, M. [Tokyo Metropolitan University (Japan); Chliapnikov, P.V. [IHEP Protvino (Russian Federation); Ciocarlan, C.; Constantinescu, S. [IFIN-HH, National Institute for Physics and Nuclear Engineering, Bucharest (Romania); Costantini, S. [Basel University (Switzerland); Curceanu, C. [IFIN-HH, National Institute for Physics and Nuclear Engineering, Bucharest (Romania); Doskarova, P. [Czech Technical University in Prague, Prague (Czech Republic); Dreossi, D. [INFN, Sezione di Trieste and Trieste University, Trieste (Italy); Drijard, D., E-mail: Daniel.Drijard@cern.ch [CERN, Geneva (Switzerland); Dudarev, A. [JINR Dubna (Russian Federation); Ferro-Luzzi, M. [CERN, Geneva (Switzerland); Fungueirino Pazos, J.L. [Santiago de Compostela University (Spain)

    2011-10-05

    The DIRAC experiment at CERN has achieved a sizeable production of {pi}{sup +{pi}-} atoms and has significantly improved the precision on its lifetime determination. From a sample of 21 227 atomic pairs, a 4% measurement of the S-wave {pi}{pi} scattering length difference |a{sub 0}-a{sub 2}|=(0.2533{sub -0.0078}{sup +0.0080}|{sub stat}{sup +0.0078}{sub -0.0073}|{sub syst})M{sub {pi}}{sup +-1} has been attained, providing an important test of Chiral Perturbation Theory.

  16. Improvement on a Michelson interferometer for bunch length measurement of a femtosecond accelerator

    International Nuclear Information System (INIS)

    Lin Xuling; Bei Hua; Zhang Jianbing; Dai Zhimin

    2009-01-01

    Based on the femtosecond accelerator facility at Shanghai Institute of Applied Physics (SINAP), a conventional far-infrared Michelson interferometer was built to measure the bunch length by means of optical autocorrelation. However, according to the preliminary experiment result, the resolution of interferometer is not good enough, because the mirror-driving mechanism makes the moving mirror tend to tilt or wobble as it retards. Considering of the allowable errors, we calculate the maximum allowable titling angle of the moving mirror, and discuss the alignment plan in this paper. (authors)

  17. An autocorrelation technique for measuring sub-picosecond bunch length using coherent transition radiation

    International Nuclear Information System (INIS)

    Barry, W.

    1991-01-01

    A new technique for determining sub-picosecond bunch length using infrared transition radiation and interferometry is proposed. The technique makes use of an infrared Michelson interferometer for measuring the autocorrelation of transition radiation emitted from a thin conducting foil placed in the beam path. The theory of coherent radiation from a charged particle beam passing through a thin conducting foil is presented. Subsequently, the analysis of this radiation through Michelson interferometry is shown to provide the autocorrelation of the longitudinal bunch profile. An example relevant to the CEBAF front end test is discussed. (author)

  18. Evaluation of a multimode fiber optic low coherence interferometer for path length resolved Doppler measurments of diffuse light

    NARCIS (Netherlands)

    Varghese, Babu; Rajan, Vinayakrishnan; van Leeuwen, Ton; Steenbergen, Wiendelt

    2007-01-01

    The performance of a graded index multimode fiber optic low coherence Mach-Zehnder interferometer with phase modulation is analyzed. Investigated aspects were its ability to measure path length distributions and to perform path length resolved Doppler measurements of multiple scattered photons in a

  19. Evaluation of a multimode fiber optic low coherence interferometer for path length resolved Doppler measurements of diffuse light

    NARCIS (Netherlands)

    Varghese, Babu; Rajan, Vinayakrishnan; van Leeuwen, Ton G.; Steenbergen, Wiendelt

    2007-01-01

    The performance of a graded index multimode fiber optic low coherence Mach-Zehnder interferometer with phase modulation is analyzed. Investigated aspects were its ability to measure path length distributions and to perform path length resolved Doppler measurements of multiple scattered photons in a

  20. [Mean length utterance (MLU) as a measure of language development of children with Down syndrome].

    Science.gov (United States)

    Marques, Suelen Fernanda; Limongi, Suelly Cecilia Olivan

    2011-01-01

    To characterize the mean length utterance in morphemes (MLU-m) and words (MLU-w) produced by children with Down syndrome (DS), and to verify the effectiveness of using EME-w as a measure of general language development of children with DS. Participants were 15 children with ages between 5 and 12 years, who were submitted to a free interaction situation. They were divided into three groups, according to chronological and mental age, as established by the results of the Primary Test of Nonverbal Intelligence. The first 100 utterances were analyzed considering: number of grammatical morphemes (GM) for articles, nouns and verbs (GM-1), and pronouns, prepositions and conjunctions (GM-2); mean length utterance for morphemes (MLU-m) and words (MLU-w). The between-groups comparison showed that the MLU averages were higher for older groups, and differences were found for all variables, except for GM-2. The same results were obtained in the within-group comparison, for all variables. There was a strong correlation between MLU-m and MLU-w. MLU-w can be used as an identification measure of general linguistic development. However, it is emphasized that the use of all MLU variables provides more efficacy in the characterization of linguistic development and the analysis of language impairments.

  1. Comparative evaluation of three methods to measure working length - Manual tactile sensation, digital radiograph, and multidetector computed tomography: Anin vitrostudy.

    Science.gov (United States)

    Dutta, Kaushik; Desai, Priti D; Das, Utapal Kumar; Sarkar, Soumayabrata

    2017-01-01

    Compare the measurement of working length with three different methods manual tactile sensation, digital radiography and Mutidetector computed tomography(MDCT). 40 human premolar extracted for orthodontic purpose were selected. Teeth were store in sodium chloride (0.9%) during the study. Access cavity was prepared and canal patency was seen with no 10 file in each tooth. Manually no 15 K file was inserted from access cavity until the tip was visible at the foramen, a silicon stopper was adjusted to the corresponding buccal cusp tip and the root canal length was measured. After that in each tooth with no-15 K file inserted from access cavity with stop at tip of buccal cusp until tip appear at foramen and x-ray was taken with digital radiograph (RVG,Satelac) and canal length was measured. After that all teeth are mounted in wax block,MDCT scan was done and in the scan images of teeth, root canal length is measured from buccal cusp tip to root end. After taking measurement of working length with all three methods and the data was stastically analyzed with One Way Analysis of variance (ANOVA) followed by Turkey's Test. ANOVA and turkeys test showed that there was no significant difference in the measurements by the three procedures (p>0.05). Working length measurement with MDCT scan and other two conventional methods does not show significant difference in measurement. Use of newer 3D imaging technique is useful in root canal treatment for measuring working length.

  2. Recent high-accuracy measurements of the 1S0 neutron-neutron scattering length

    International Nuclear Information System (INIS)

    Howell, C.R.; Chen, Q.; Gonzalez Trotter, D.E.; Salinas, F.; Crowell, A.S.; Roper, C.D.; Tornow, W.; Walter, R.L.; Carman, T.S.; Hussein, A.; Gibbs, W.R.; Gibson, B.F.; Morris, C.; Obst, A.; Sterbenz, S.; Whitton, M.; Mertens, G.; Moore, C.F.; Whiteley, C.R.; Pasyuk, E.; Slaus, I.; Tang, H.; Zhou, Z.; Gloeckle, W.; Witala, H.

    2000-01-01

    This paper reports two recent high-accuracy determinations of the 1 S 0 neutron-neutron scattering length, a nn . One was done at the Los Alamos National Laboratory using the π - d capture reaction to produce two neutrons with low relative momentum. The neutron-deuteron (nd) breakup reaction was used in other measurement, which was conducted at the Triangle Universities Nuclear Laboratory. The results from the two determinations were consistent with each other and with previous values obtained using the π - d capture reaction. The value obtained from the nd breakup measurements is a nn = -18.7 ± 0.1 (statistical) ± 0.6 (systematic) fm, and the value from the π - d capture experiment is a nn = -18.50 ± 0.05 ± 0.53 fm. The recommended value is a nn = -18.5 ± 0.3 fm. (author)

  3. Pelvic reference selection in patients with unilateral Crowe type IV DDH for measuring leg length inequality.

    Science.gov (United States)

    Zhang, Yanbo; Chang, Fei; Wang, Chenyu; Yang, Modi; Wang, Jincheng

    2015-01-01

    We identified the presence of deformities in the affected pelvis of unilateral Crowe type IV DDH patients, and if present, whether the teardrop and ischial lines were parallel with the sacral base line. We also verified whether the sacral base line provided a better pelvic landmark than the teardrop line for determining leg length inequality (LLI). After leveling the pelvis by using a block to lift the short leg, standard anterior-posterior full-length radiography was performed on 10 patients and 10 healthy volunteers as controls. The ratio of pelvic heights on each side of the pelvis, the angles formed by the sacral base line and the other 2 lines between 2 groups were measured. LLI were measured by sacral base line and teardrop line respectively. The ratio between the pelvic heights was lower in the patient group than in the control group (0.95 versus 0.99). The angles between the teardrop and ischial lines and the sacral base line in the patient group were both greater than in the control group (6.08° versus 0.92° and 7.13° versus 0.97°). LLI measured from the sacral base line was larger than from the teardrop line in the patient group (5.55 cm versus 4.36 cm). There was pelvic asymmetry and the sacral base line was not parallel with the other 2 lines in unilateral Crowe type IV DDH. The leveled sacral base line was perpendicular to the longitudinal axis of the body, and may be a better choice for accurate LLI measurement in this situation.

  4. Measurement of clavicular length and shortening after a midshaft clavicular fracture: Spatial digitization versus planar roentgen photogrammetry.

    Science.gov (United States)

    Stegeman, Sylvia A; de Witte, Pieter Bas; Boonstra, Sjoerd; de Groot, Jurriaan H; Nagels, Jochem; Krijnen, Pieta; Schipper, Inger B

    2016-08-01

    Clavicular shortening after fracture is deemed prognostic for clinical outcome and is therefore generally assessed on radiographs. It is used for clinical decision making regarding operative or non-operative treatment in the first 2weeks after trauma, although the reliability and accuracy of the measurements are unclear. This study aimed to assess the reliability of roentgen photogrammetry (2D) of clavicular length and shortening, and to compare these with 3D-spatial digitization measurements, obtained with an electromagnetic recording system (Flock of Birds). Thirty-two participants with a consolidated non-operatively treated two or multi-fragmented dislocated midshaft clavicular fracture were analysed. Two observers measured clavicular lengths and absolute and proportional clavicular shortening on radiographs taken before and after fracture consolidation. The clavicular lengths were also measured with spatial digitization. Inter-observer agreement on the radiographic measurements was assessed using the Intraclass Correlation Coefficient (ICC). Agreement between the radiographic and spatial digitization measurements was assessed using a Bland-Altman plot. The inter-observer agreement on clavicular length, and absolute and proportional shortening on trauma radiographs was almost perfect (ICC>0.90), but moderate for absolute shortening after consolidation (ICC=0.45). The Bland-Altman plot compared measurements of length on AP panorama radiographs with spatial digitization and showed that planar roentgen photogrammetry resulted in up to 37mm longer and 34mm shorter measurements than spatial digitization. Measurements of clavicular length on radiographs are highly reliable between observers, but may not reflect the actual length and shortening of the clavicle when compared to length measurements with spatial digitization. We recommend to use proportional shortening when measuring clavicular length or shortening on radiographs for clinical decision making. Copyright

  5. Foot length measurements of newborns of high and low risk pregnancies.

    Science.gov (United States)

    Salge, Ana Karina Marques; Rocha, Érika Lopes; Gaíva, Maria Aparecida Munhoz; Castral, Thaíla Correa; Guimarães, Janaína Valadares; Xavier, Raphaela Maioni

    2017-03-09

    Comparing foot length measurements of newborns in high and low risk pregnancies at a public hospital in Goiânia, GO, Brazil. A cross-sectional study carried out between April, 2013 and May, 2015, with a sample consisting of 180 newborns; 106 infants of women from high-risk pregnancies and 74 of women from low-risk pregnancies. Data were descriptively analyzed. Foot length measurement was performed using a stiff transparent plastic ruler, graduated in millimeters. The length of both feet was measured from the tip of the hallux (big toe) to the end of the heel. A statistically significant relationship was found between the foot length and newborn's weight, between the cephalic and thoracic perimeters in the high-risk group and between the cephalic perimeter in the control group. There is a need for creating cut-off points to identify newborns with intrauterine growth disorders using foot length. Comparar as medidas do comprimento hálux-calcâneo de recém-nascidos em gestações de alto e baixo risco em um hospital público de Goiânia, GO. Estudo transversal, realizado no período de abril de 2013 a maio de 2015, cuja amostra constituiu-se de 180 recém-nascidos, 106 filhos de mulheres com gestação de alto risco e 74 de mulheres com gestação de baixo risco. Os dados foram analisados descritivamente. A medida do comprimento hálux-calcâneo foi realizada utilizando-se de régua plástica transparente rígida, graduada em milímetros. Foram medidos ambos os pés, aferindo-se o comprimento da ponta do hálux até a extremidade do calcâneo. Foi encontrada relação estatisticamente significante entre o comprimento hálux-calcâneo e o peso do recém-nascido, entre os perímetros cefálico e torácico no grupo de alto risco e entre o perímetro cefálico no grupo controle. Existe necessidade da criação de pontos de corte para identificar recém-nascidos com desvios de crescimento intrauterino utilizando-se do comprimento hálux-calcâneo. Comparar las mediciones

  6. Retrieval of Effective Correlation Length and Snow Water Equivalent from Radar and Passive Microwave Measurements

    Directory of Open Access Journals (Sweden)

    Juha Lemmetyinen

    2018-01-01

    Full Text Available Current methods for retrieving SWE (snow water equivalent from space rely on passive microwave sensors. Observations are limited by poor spatial resolution, ambiguities related to separation of snow microstructural properties from the total snow mass, and signal saturation when snow is deep (~>80 cm. The use of SAR (Synthetic Aperture Radar at suitable frequencies has been suggested as a potential observation method to overcome the coarse resolution of passive microwave sensors. Nevertheless, suitable sensors operating from space are, up to now, unavailable. Active microwave retrievals suffer, however, from the same difficulties as the passive case in separating impacts of scattering efficiency from those of snow mass. In this study, we explore the potential of applying active (radar and passive (radiometer microwave observations in tandem, by using a dataset of co-incident tower-based active and passive microwave observations and detailed in situ data from a test site in Northern Finland. The dataset spans four winter seasons with daily coverage. In order to quantify the temporal variability of snow microstructure, we derive an effective correlation length for the snowpack (treated as a single layer, which matches the simulated microwave response of a semi-empirical radiative transfer model to observations. This effective parameter is derived from radiometer and radar observations at different frequencies and frequency combinations (10.2, 13.3 and 16.7 GHz for radar; 10.65, 18.7 and 37 GHz for radiometer. Under dry snow conditions, correlations are found between the effective correlation length retrieved from active and passive measurements. Consequently, the derived effective correlation length from passive microwave observations is applied to parameterize the retrieval of SWE using radar, improving retrieval skill compared to a case with no prior knowledge of snow-scattering efficiency. The same concept can be applied to future radar

  7. Use of a corrugated beam pipe as a passive deflector for bunch length measurements

    Science.gov (United States)

    Seok, Jimin; Chung, Moses; Kang, Heung-Sik; Min, Chang-Ki; Na, Donghyun

    2018-02-01

    We report the experimental demonstration of bunch length measurements using a corrugated metallic beam pipe as a passive deflector. The corrugated beam pipe has been adopted for reducing longitudinal chirping after the bunch compressors in several XFEL facilities worldwide. In the meantime, there have been attempts to measure the electron bunch's longitudinal current profile using the dipole wakefields generated in the corrugated pipe. Nevertheless, the bunch shape reconstructed from the nonlinearly deflected beam suffers from significant distortion, particularly near the head of the bunch. In this paper, we introduce an iterative process to improve the resolution of the bunch shape reconstruction. The astra and elegant simulations have been performed for pencil beam and cigar beam cases, in order to verify the effectiveness of the reconstruction process. To overcome the undesirable effects of transverse beam spreads, a measurement scheme involving both the corrugated beam pipe and the spectrometer magnet has been employed, both of which do not require a dedicated (and likely very expensive) rf system. A proof-of-principle experiment was carried out at Pohang Accelerator Laboratory (PAL) Injector Test Facility (ITF), and its results are discussed together with a comparison with the rf deflector measurement.

  8. Use of a corrugated beam pipe as a passive deflector for bunch length measurements

    Directory of Open Access Journals (Sweden)

    Jimin Seok

    2018-02-01

    Full Text Available We report the experimental demonstration of bunch length measurements using a corrugated metallic beam pipe as a passive deflector. The corrugated beam pipe has been adopted for reducing longitudinal chirping after the bunch compressors in several XFEL facilities worldwide. In the meantime, there have been attempts to measure the electron bunch’s longitudinal current profile using the dipole wakefields generated in the corrugated pipe. Nevertheless, the bunch shape reconstructed from the nonlinearly deflected beam suffers from significant distortion, particularly near the head of the bunch. In this paper, we introduce an iterative process to improve the resolution of the bunch shape reconstruction. The astra and elegant simulations have been performed for pencil beam and cigar beam cases, in order to verify the effectiveness of the reconstruction process. To overcome the undesirable effects of transverse beam spreads, a measurement scheme involving both the corrugated beam pipe and the spectrometer magnet has been employed, both of which do not require a dedicated (and likely very expensive rf system. A proof-of-principle experiment was carried out at Pohang Accelerator Laboratory (PAL Injector Test Facility (ITF, and its results are discussed together with a comparison with the rf deflector measurement.

  9. Axial Length Measurement Failure Rates with the IOLMaster and Lenstar LS 900 in Eyes with Cataract.

    Science.gov (United States)

    McAlinden, Colm; Wang, Qinmei; Pesudovs, Konrad; Yang, Xin; Bao, Fangjun; Yu, Ayong; Lin, Shishi; Feng, Yifan; Huang, Jinhai

    2015-01-01

    To evaluate axial length (AL) measurement failure rate with the IOLMaster (Carl Zeiss AG, Germany) and Lenstar LS 900 (Haag-Streit AG, Switzerland) in eyes with cataract. Two hundred and ninety-six eyes of 170 patients with cataract were enrolled. Cataract type and severity were graded using the Lens Opacities Classification System III (LOCS III) and AL measurements were attempted with IOLMaster (version 5.4) and Lenstar LS 900 (version 1.1). Chi-squared analysis was used to assess if the difference in AL measurement acquisition rate was statistically significant between the two devices. The association of the different cataract types and severity with the AL measurement acquisition rate was evaluated with logistic regression analysis. AL measurements were obtained in 184 eyes (62.16%) using the IOLMaster and 191 eyes (64.53%) using the Lenstar, which corresponds to a failure rate of 37.84% and 35.47% respectively. Chi-square analysis indicated no significant difference between the Lenstar and IOLMaster for AL measurement failure rate (x2 = 0.356, P = 0.550). Logistic regression analysis indicated no association between acquisition rates and cortical or nuclear cataracts with either device. There was a statistically significant association between acquisition rates and increasing severity of posterior subcapsular cataracts with the IOLMaster (β = -1.491, PLS 900 (β = -1.507, PLS 900 have similar AL measurement failure rates (35-38%) for Chinese public hospital cataract patients. Increasing severity of posterior subcapsular cataracts was problematic for both devices.

  10. A Study of an Information Retrieval Performance Measure: Expected Search Length as a Function of File Size and Organization.

    Science.gov (United States)

    Deutsch, Donald R.; Kraft, Donald H.

    A framework is developed to evaluate expected search length, an important measure of an information storage and retrieval system's performance, as a function of the size of the information file and its organization in terms of indexing search structure. Previous research pertaining to search length by W.S. Cooper and others is surveyed and…

  11. The validity of cone-beam computed tomography in measuring root canal length using a gold standard

    NARCIS (Netherlands)

    Liang, Y.H.; Jiang, L.; Chen, C.; Gao, X.J.; Wesselink, P.R.; Wu, M.K.; Shemesh, H.

    2013-01-01

    Introduction The distance between a coronal reference point and the major apical foramen is important for working length determination. The aim of this in vitro study was to determine the accuracy of root canal length measurements performed with cone-beam computed tomographic (CBCT) scans using a

  12. First $\\pi K$ atom lifetime and $\\pi K$ scattering length measurements

    CERN Document Server

    Adeva, B; Allkofer, Y; Amsler, C; Anania, A; Aogaki, S; Benelli, A; Brekhovskikh, V; Cechak, T; Chiba, M; Chliapnikov, P; Ciocarlan, C; Constantinescu, S; Doskarova, P; Drijard, D; Dudarev, A; Duma, M; Dumitriu, D; Fluerasu, D; Gorin, A; Gorchakov, O; Gritsay, K; Guaraldo, C; Gugiu, M; Hansroul, M; Hons, Z; Horikawa, S; Iwashita, Y; Karpukhin, V; Kluson, J; Kobayashi, M; Kruglov, V; Kruglova, L; Kulikov, A; Kulish, E; Kuptsov, A; Lamberto, A; Lanaro, A; Lednicky, R; Marinas, C; Martincik, J; Nemenov, L; Nikitin, M; Okada, K; Olchevskii, V; Pentia, M; Penzo, A; Plo, M; Ponta, T; Prusa, P; Rappazzo, G; Romero Vidal, A; Ryazantsev, A; Rykalin, V; Schacher, J; Sidorov, A; Smolik, J; Sugimoto, S; Takeutchi, F; Tauscher, L; Trojek, T; Trusov, S; Urban, T; Vrba, T; Yazkov, V; Yoshimura, Y; Zhabitsky, M; Zrelov, P

    2014-01-01

    The results of a search for hydrogen-like atoms consisting of $\\pi^{\\mp}K^{\\pm}$ mesons are presented. Evidence for $\\pi K$ atom production by 24 GeV/c protons from CERN PS interacting with a nickel target has been seen in terms of characteristic $\\pi K$ pairs from their breakup in the same target ($178 \\pm 49$) and from Coulomb final state interaction ($653 \\pm 42$). Using these results the analysis yields a first value for the $\\pi K$ atom lifetime of $\\tau=(2.5_{-1.8}^{+3.0})$ fs and a first model-independent measurement of the S-wave isospin-odd $\\pi K$ scattering length $\\left|a_0^-\\right|=\\frac{1}{3}\\left|a_{1/2}-a_{3/2}\\right|= \\left( 0.11_{-0.04}^{+0.09} \\right)M_{\\pi}^{-1}$ ($a_I$ for isospin $I$).

  13. Method for single-shot measurement of picosecond laser pulse-lengths without electronic time dispersion

    International Nuclear Information System (INIS)

    Kyrala, G.A.

    1987-01-01

    A two-source shear pattern recording is proposed as a method for single-shot measurement of the pulse shape from nearly monochromatic sources whose pulse lengths are shorter than their coherence times. The basis of this method relies on the assertion that if two identical electromagnetic pulses are recombined with a time delay greater than the sum of their pulse widths, the recordable spatial pattern has no fringes in it. At an arbitrary delay, translated into an actual spatial recording position, the recorded modulated intensity will sample the corresponding laser intensity at that delay time, but with a modulation due to the coherence function of the electromagnetic pulse. Two arrangements are proposed for recording the pattern. The principles, the design parameters, and the methodologies of these arrangements are presented. Resolutions of the configurations and their limitations are given as well

  14. Measurement of the neutron-neutron scattering length using the π-d capture reaction

    International Nuclear Information System (INIS)

    Chen, Q.; Howell, C. R.; Kiser, M. R.; Roper, C. D.; Salinas, F.; Setze, H. R.; Tornow, W.; Walter, R. L.; Carman, T. S.; Gibbs, W. R.; Gibson, B. F.; Morris, C.; Obst, A.; Sterbenz, S.; Whitton, M.; Hussein, A.; Mertens, G.; Moore, C. F.; Whiteley, C. R.; Pasyuk, E.

    2008-01-01

    We have determined a value for the 1 S 0 neutron-neutron scattering length (a nn ) from high-precision measurements of time-of-flight spectra of neutrons from the 2 H(π - ,n γ) n capture reaction. The measurements were done at the Los Alamos Meson Physics Facility by the E1286 Collaboration. The high spatial resolution of our γ-ray detector enabled us to make a detailed assessment of the systematic uncertainties in our techniques. The value obtained in the present work is a nn =-18.63±0.10 (statistical) ± 0.44 (systematic) ± 0.30 (theoretical) fm. This result is consistent with previous determinations of a nn from the π - d capture reaction. We found that the analysis of the data with calculations that use a relativistic phase-space factor gives a more negative value for a nn by 0.33 fm over the analysis done using a nonrelativistic phase-space factor. Combining the present result with the previous ones from π - d capture gives a nn =-18.63±0.27(expt)±0.30 fm (theory). For the first time the combined statistical and systematic experimental uncertainty in a nn is smaller than the theoretical uncertainty and comparable to the uncertainty in the proton-proton 1 S 0 scattering length (a pp ). This average value of a nn when corrected for the magnetic-moment interaction of the two neutrons becomes -18.9 ± 0.4 fm, which is 1.6 ± 0.5 fm different from the recommended value of a pp , thereby confirming charge symmetry breaking at the 1% confidence level

  15. Most suitable mother wavelet for the analysis of fractal properties of stride interval time series via the average wavelet coefficient method.

    Science.gov (United States)

    Zhang, Zhenwei; VanSwearingen, Jessie; Brach, Jennifer S; Perera, Subashan; Sejdić, Ervin

    2017-01-01

    Human gait is a complex interaction of many nonlinear systems and stride intervals exhibiting self-similarity over long time scales that can be modeled as a fractal process. The scaling exponent represents the fractal degree and can be interpreted as a "biomarker" of relative diseases. The previous study showed that the average wavelet method provides the most accurate results to estimate this scaling exponent when applied to stride interval time series. The purpose of this paper is to determine the most suitable mother wavelet for the average wavelet method. This paper presents a comparative numerical analysis of 16 mother wavelets using simulated and real fractal signals. Simulated fractal signals were generated under varying signal lengths and scaling exponents that indicate a range of physiologically conceivable fractal signals. The five candidates were chosen due to their good performance on the mean square error test for both short and long signals. Next, we comparatively analyzed these five mother wavelets for physiologically relevant stride time series lengths. Our analysis showed that the symlet 2 mother wavelet provides a low mean square error and low variance for long time intervals and relatively low errors for short signal lengths. It can be considered as the most suitable mother function without the burden of considering the signal length. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Length, width and centroid distance as measures of teams tactical performance in youth football.

    Science.gov (United States)

    Folgado, Hugo; Lemmink, Koen A P M; Frencken, Wouter; Sampaio, Jaime

    2014-01-01

    Small-sided games are commonly used in training and teaching contexts of football. However, few studies have focused on the tactical implications of this type of drills. The aim of this study is to identify how tactical collective behaviour varies with age in different small-sided game formats. We investigated the in-game field position in three different age groups of youth football players [under-9 (n=10; age = 8.5 ± 0.53), under-11 (n=10; age = 10.4 ± 0.52) and under-13 (n=10; age = 12.7 ± 0.48)], participating in two different small-sided game conditions (GK + 3 × 3 + GK and GK + 4 × 4 + GK). A team variable was created based on the players' length per width ratio (lpwratio), and a match variable was calculated as the distance between the centroid of the two teams. Results show that team variable values were influenced by the age of the players, as younger teams tend to present a higher value of lpwratio in their dispersion on the pitch. The variability of this variable also showed a decrease for teams with older players, suggesting a more consistent application of the width (stretching and creating space) and concentration (compressing into a confined area) principles of play and reflecting a higher level of collective tactical behaviour. Match variable showed a larger centroid distance for the older age groups in comparison with the younger players in the GK + 3 × 3 + GK, while all age groups demonstrated similar large centroid distances in the GK + 4 × 4 + GK game format. These results suggest that length and width ratio and centroid distance are useful measures of tactical performance in small-sided games in youth football.

  17. Multiple measures of adiposity are associated with mean leukocyte telomere length in the Northern Finland birth cohort 1966

    OpenAIRE

    Buxton, Jessica L.; Das, Shikta; Rodriguez, Alina; Kaakinen, Marika; Couto Alves, Alexessander; Sebert, Sylvain; Millwood, Iona Y.; Laitinen, Jaana; O’Reilly, Paul F.; Jarvelin, Marjo-Riitta; Blakemore, Alexandra I. F.

    2014-01-01

    Studies of leukocyte telomere length (LTL) and adiposity have produced conflicting results, and the relationship between body mass index (BMI) and telomere length throughout life remains unclear. We therefore tested association of adult LTL measured in 5,598 participants with: i) childhood growth measures (BMI and age at adiposity rebound (AR)); ii) change in BMI from childhood to adulthood and iii) adult BMI, waist-to-hip ratio (WHR), body adiposity index (BAI). Childhood BMI at AR was posit...

  18. Ultrasonic motion analysis system - measurement of temporal and spatial gait parameters

    NARCIS (Netherlands)

    Huitema, RB; Hof, AL; Postema, K

    The duration of stance and swing phase and step and stride length are important parameters in human gait. In this technical note a low-cost ultrasonic motion analysis system is described that is capable of measuring these temporal and spatial parameters while subjects walk on the floor. By using the

  19. Cell length measurements in longitudinal smooth muscle strips of the pig urinary bladder

    NARCIS (Netherlands)

    E. van Asselt (Els); R. Schot (Rachel); R. van Mastrigt (Ron)

    1993-01-01

    textabstractIn this study the length of smooth muscle cells in muscle bundles of pig urinary bladder wall was determined after dissection in Tyrode buffers with different calcium concentrations ([Ca2+]). Previous studies have shown that the length of isolated smooth muscle cells decreases with an

  20. How Does Definition of Minimum Break Length Affect Objective Measures of Sitting Outcomes Among Office Workers?

    DEFF Research Database (Denmark)

    Kloster, Stine; Danquah, Ida Høgstedt; Holtermann, Andreas

    2017-01-01

    described how the definition of minimum break duration affects sitting outcomes. Therefore, the aim was to address how definitions of break length affect total sitting time, number of sit-to-stand transitions, prolonged sitting periods and time accumulated in prolonged sitting periods among office workers......-to-stand transitions decreased, and number of prolonged sitting periods and total time accumulated in prolonged sitting periods increased, with increasing minimum break length. Total sitting time was not influenced by varying break length. CONCLUSIONS: The definition of minimum break length influenced the sitting...... outcomes with the exception of total sitting time. A standard definition of break length is needed for comparison and interpretation of studies in the evolving research field of sedentary behaviour....

  1. Model of vortex dynamics in superconducting films in two-coil measurements of the coherence length

    Science.gov (United States)

    Lemberger, Thomas; Loh, Yen Lee

    In two-coil measurements on superconducting films, a magnetic field from a small coil is applied to the center of the film. When the amplitude of the ac field is increased, the film undergoes a transition from the ``Meissner'' state to a state with vortices and antivortices. Ultimately, the vortex density matches the applied magnetic field and field screening is negligible. Experimentally, the field at the transition is related to the superconducting coherence length, although a full theory of the relationship is lacking. We show that the mutual inductance between drive and pickup coils, on opposite sides of the film, as a function of ac field amplitude is well-described by a phenomenological model in which vortices and antivortices appear together in the film at the radius where the induced supercurrent is strongest, and then they move through a landscape of moderately strong vortex pinning sites. Work at OSU supported by DOE-Basic Energy Sciences through Grant No. FG02-08ER46533.

  2. Is sonographically measured cervical length at 37 weeks of gestation associated with intrapartum cesarean section? A prospective cohort study.

    Science.gov (United States)

    de Vries, Bradley; Narayan, Rajit; McGeechan, Kevin; Santiagu, Stanley; Vairavan, Ramesh; Burke, Minke; Phipps, Hala; Hyett, Jon

    2018-02-16

    Cesarean section rates continue to increase globally. Prediction of intrapartum cesarean section could lead to preventive measures. Our aim was to assess the association between sonographically measured cervical length at 37 weeks of gestation and cesarean section among women planning a vaginal birth. The population was women with a low-risk pregnancy or with gestational diabetes. This was a prospective cohort study conducted in a tertiary referral hospital in Sydney, Australia. In all, 212 women with a low-risk pregnancy or with gestational diabetes were recruited including 158 nulliparous and 54 parous women. Maternal demographic, clinical and ultrasound characteristics were collected at 37 weeks of gestation. Semi-Bayesian logistic regression and Markov chain Monte Carlo simulation were used to assess the relationship between cervical length and cesarean section in labor. Rates of cesarean section were 5% (2/55) for cervical length ≤20 mm, 17% (17/101) for cervical length 20-32 mm, and 27% (13/56) for cervical length >32 mm. These rates were 4, 22 and 33%, respectively, in nulliparous women. In the semi-Bayesian analysis, the odds ratio for cesarean section was 6.2 (95% confidence interval 2.2-43) for cervical length 20-32 mm and 10 (95% confidence interval 4.8-74) for cervical length >32 mm compared with the lowest quartile of cervical length, after adjusting for maternal age, parity, height, prepregnancy body mass index, gestational diabetes, induction of labor, neonatal sex and birthweight centile. Cervical length at 37 weeks of gestation is associated with intrapartum cesarean section. © 2018 Nordic Federation of Societies of Obstetrics and Gynecology.

  3. Recommended number of strides for automatic assessment of gait symmetry and regularity in above-knee amputees by means of accelerometry and autocorrelation analysis

    Directory of Open Access Journals (Sweden)

    Tura Andrea

    2012-02-01

    Full Text Available Abstract Background Symmetry and regularity of gait are essential outcomes of gait retraining programs, especially in lower-limb amputees. This study aims presenting an algorithm to automatically compute symmetry and regularity indices, and assessing the minimum number of strides for appropriate evaluation of gait symmetry and regularity through autocorrelation of acceleration signals. Methods Ten transfemoral amputees (AMP and ten control subjects (CTRL were studied. Subjects wore an accelerometer and were asked to walk for 70 m at their natural speed (twice. Reference values of step and stride regularity indices (Ad1 and Ad2 were obtained by autocorrelation analysis of the vertical and antero-posterior acceleration signals, excluding initial and final strides. The Ad1 and Ad2 coefficients were then computed at different stages by analyzing increasing portions of the signals (considering both the signals cleaned by initial and final strides, and the whole signals. At each stage, the difference between Ad1 and Ad2 values and the corresponding reference values were compared with the minimum detectable difference, MDD, of the index. If that difference was less than MDD, it was assumed that the portion of signal used in the analysis was of sufficient length to allow reliable estimation of the autocorrelation coefficient. Results All Ad1 and Ad2 indices were lower in AMP than in CTRL (P Conclusions Without the need to identify and eliminate the phases of gait initiation and termination, twenty strides can provide a reasonable amount of information to reliably estimate gait regularity in transfemoral amputees.

  4. Triage by cervical length sonographic measurements for targeted therapy in threatened preterm labor: A double blind randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Homeira Vafaei

    2017-11-01

    Full Text Available Background: Preterm labor and birth are associated with several neonatal complications including respiratory distress syndrome and intraventricular hemorrhage. Differentiating true and false labor pain is a dilemma to obstetricians. Objective: To elucidate the role of cervical length measurement in prediction of birth in pregnant women with threatened preterm labor. Materials and Methods: In this double blind randomized clinical trial, 120 women with gestational age <34 wk who presented painful uterine contractions randomly assigned to undergo measurement of cervical length. Patients were registered in the hospital and a unit number was given. Based on the unit numbers, patients were randomly assigned to two groups using a computerized random digit generator. All participants were managed accordingly (n=65 or to receive tocolysis as planned (n=55. Tocolysis was prescribed when cervical length was <15 mm while those with cervical length ≥15 mm were managed expectantly. Delivery within 7 days of the presentation was the primary outcome. Results: This RCT showed in case group, 78.9% of patient with cervical length <15 mm were delivered within 7 days and only 21.1% of them maintained their pregnancy. Of those with cervical length ≥15 mm, only 15.2% were delivered within the study period and the rest (84.8% maintained their pregnancy (p<0.001. Conclusion: “Our results indicate that in women who presented preterm labor symptoms, cervical length measurement will result in decreased unnecessary tocolytic treatment. Women with cervical length ≥15mm should not receive tocolysis, however, withholding corticosteroid therapy in these patients needs further evidence.

  5. Length distribution of single-walled carbon nanotubes in aqueous suspension measured by electrospray differential mobility analysis.

    Science.gov (United States)

    Pease, Leonard F; Tsai, De-Hao; Fagan, Jeffery A; Bauer, Barry J; Zangmeister, Rebecca A; Tarlov, Michael J; Zachariah, Michael R

    2009-12-01

    The first characterization of the length distribution of single-walled carbon nanotubes (SWCNT) dispersed in a liquid by electrospray differential mobility analysis (ES-DMA) is presented. Although an understanding of geometric properties of SWCNTs, including length, diameter, aspect ratio, and chirality, is essential for commercial applications, rapid characterization of nanotube length distributions remains challenging. Here the use of ES-DMA to obtain length distributions of DNA-wrapped SWCNTs dispersed in aqueous solutions is demonstrated. Lengths measured by ES-DMA compare favorably with those obtained from multiangle light scattering, dynamic light scattering, field flow fractionation with UV/vis detection, and atomic force microscopy, validating ES-DMA as a technique to measure SWCNTs of <250 nm in length. The nanotubes are previously purified and dispersed by wrapping with oligomeric DNA in aqueous solution and centrifuging to remove bundles and amorphous carbon. These dispersions are particularly attractive due to their amenability to bulk processing, ease of storage, high concentration, compatibility with biological and high-throughput manufacturing environments, and for their potential applications ranging from electronics and hydrogen-storage vessels to anticancer agents.

  6. Accuracy of measurement by laser diffraction method of length of contracting muscle sarcomeres

    Energy Technology Data Exchange (ETDEWEB)

    Klimov, A.A.; Andreyev, O.A.

    The method of laser beam diffraction was used on striate muscle fibers to study changes in sarcomere length during contraction, as determined by the angular distance between (+1)-(left) and (-1)-(right) diffraction maximums. The course of force development was recorded simultaneously. The absolute margin of error in determining the mean length of sarcomeres did not exceed 0.05 ..mu..m in the range of 1.8 to 2.8 ..mu..m lengths, and 0.1 ..mu..m in the range of 2.8 to 3.3. Changes in mean length of sarcomeres were recorded with accuracy to 0.003 ..mu..m with concurrent monitoring of positions (+1) and (-1) maximums. It was demonstrated that during fiber contraction there is shifting not only of (+1) and (-1) maximums, but (0) maximum also, which is attributable to the effects of light refraction with change in shape of illuminated segment of fiber. This change can be caused by redistribution of sarcomere lengths along the axis of the fiber during contraction and, accordingly, local changes in fiber diameter.

  7. Unfavorable Strides in Cache Memory Systems (RNR Technical Report RNR-92-015

    Directory of Open Access Journals (Sweden)

    David H. Bailey

    1995-01-01

    Full Text Available An important issue in obtaining high performance on a scientific application running on a cache-based computer system is the behavior of the cache when data are accessed at a constant stride. Others who have discussed this issue have noted an odd phenomenon in such situations: A few particular innocent-looking strides result in sharply reduced cache efficiency. In this article, this problem is analyzed, and a simple formula is presented that accurately gives the cache efficiency for various cache parameters and data strides.

  8. Effects of changing the random number stride in Monte Carlo calculations

    International Nuclear Information System (INIS)

    Hendricks, J.S.

    1991-01-01

    This paper reports on a common practice in Monte Carlo radiation transport codes which is to start each random walk a specified number of steps up the random number sequence from the previous one. This is called the stride in the random number sequence between source particles. It is used for correlated sampling or to provide tree-structured random numbers. A new random number generator algorithm for the major Monte Carlo code MCNP has been written to allow adjustment of the random number stride. This random number generator is machine portable. The effects of varying the stride for several sample problems are examined

  9. Measured tube technique for ensuring the correct length of slippery artificial chordae in mitral valvuloplasty.

    Science.gov (United States)

    Matsui, Yoshiro; Kubota, Suguru; Sugiki, Hiroshi; Wakasa, Satoshi; Ooka, Tomonori; Tachibana, Tsuyoshi; Sasaki, Shigeyuki

    2011-09-01

    Mitral valvuloplasty using Gore-Tex (W.L. Gore & Associates, Inc, Flagstaff, AZ) as artificial chordae is often associated with difficulties in determining the length of the artificial chordae, as well as preventing knot slippage, especially for patients with broad anterior leaflet prolapse. We describe a simple technique that enables surgeons to easily determine the correct length of the artificial chordae and tie slippery knots without using a specific device. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Vertebral height as the measure of lesion length in carcinoma of the ...

    African Journals Online (AJOL)

    With the modified tech- nique it was possible to decrease treat- ment length and the number of nor- mal oesophageal mucosa in the treat- ment volume, thereby reducing the chance of treatment-related complica- tions such as strictures and ulceration. Introduction. The majority of patients with car- cinoma of the oesophagus ...

  11. Improved theory of time domain reflectometry with variable coaxial cable length for electrical conductivity measurements

    Science.gov (United States)

    Although empirical models have been developed previously, a mechanistic model is needed for estimating electrical conductivity (EC) using time domain reflectometry (TDR) with variable lengths of coaxial cable. The goals of this study are to: (1) derive a mechanistic model based on multisection tra...

  12. Importance of epoch length and registration time on accelerometer measurements in younger children

    DEFF Research Database (Denmark)

    Dencker, M; Svensson, J; El-Naaman, B

    2012-01-01

    The aim of this study was to investigate the effect of epoch length on accumulation of minutes of physical activity per day over a spectrum of intensities, and the effect that selection of number of hours of acceptable registration required per day had on number of days that were considered accep...

  13. Accuracy and head positioning effects on measurements of anterior tooth length using 3-dimensional and conventional dental panoramic radiography.

    Science.gov (United States)

    Kitai, Noriyuki; Murabayashi, Manabu; Sugimoto, Hiroshi; Fujiwara, Atsushi; Tome, Wakako; Katsumata, Akitoshi

    2017-03-01

    The purposes of this study were to examine the accuracy and the head positioning effects on measurements of anterior tooth length using 3-dimensional (3D) and conventional dental panoramic radiography and to investigate whether 3D panoramic radiography is suitable for the evaluation of anterior tooth length. A simulated human head was radiographed at 4, 8, and 12 mm displaced positions, and at 5°, 10°, and 15° tilted positions from the standard head position using 3D and conventional panoramic radiography, and also using cone-beam computed tomography. Anterior tooth lengths were measured on the panoramic and cone-beam computed tomography images. The values for the standard head position in the panoramic radiographs were defined as the standard values. Measurement error was defined as the standard value minus the cone-beam computed tomography value on each panoramic radiograph. The head position ratio of the measurement value to the standard value at each head position was calculated. Measurement errors for the 3D panoramic radiographs were significantly smaller than those for the conventional panoramic radiographs. In the 3D panoramic radiographs, the head position ratios at the 4, 8, and 12 mm displaced positions and at the 5° tilted position were within ±5% of the standard value. Three-dimensional panoramic radiography is suitable for the quantitative evaluation of anterior tooth length with high accuracy. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  14. Influence of Landscape Coverage on Measuring Spatial and Length Properties of Rock Fracture Networks: Insights from Numerical Simulation

    Science.gov (United States)

    Cao, Wenzhuo; Lei, Qinghua

    2018-01-01

    Natural fractures are ubiquitous in the Earth's crust and often deeply buried in the subsurface. Due to the difficulty in accessing to their three-dimensional structures, the study of fracture network geometry is usually achieved by sampling two-dimensional (2D) exposures at the Earth's surface through outcrop mapping or aerial photograph techniques. However, the measurement results can be considerably affected by the coverage of forests and other plant species over the exposed fracture patterns. We quantitatively study such effects using numerical simulation. We consider the scenario of nominally isotropic natural fracture systems and represent them using 2D discrete fracture network models governed by fractal and length scaling parameters. The groundcover is modelled as random patches superimposing onto the 2D fracture patterns. The effects of localisation and total coverage of landscape patches are further investigated. The fractal dimension and length exponent of the covered fracture networks are measured and compared with those of the original non-covered patterns. The results show that the measured length exponent increases with the reduced localisation and increased coverage of landscape patches, which is more evident for networks dominated by very large fractures (i.e. small underlying length exponent). However, the landscape coverage seems to have a minor impact on the fractal dimension measurement. The research findings of this paper have important implications for field survey and statistical analysis of geological systems.

  15. Knee Stretch Walking Method for Biped Robot: Using Toe and Heel Joints to Increase Walking Strides

    Science.gov (United States)

    Sato, Takahiko; Shimmyo, Shuhei; Nakazato, Miki; Mikami, Kei; Sato, Tomoya; Sakaino, Sho; Ohnishi, Kouhei

    This paper proposes a knee stretch walking method for biped robots; the method involves the use of the toes and heel joints to increase walking strides. A knee can be stretched by switching control variables. By a knee stretch walking with heel contacts to the ground and toe takeoffs from the ground, biped robots can increase their walking stride and speed. The validity of the proposed method is confirmed by simulation and experimental results.

  16. Measurements of 3D slip velocities and plasma column lengths of a gliding arc discharge

    DEFF Research Database (Denmark)

    Zhu, Jiajian; Gao, Jinlong; Ehn, Andreas

    2015-01-01

    A non-thermal gliding arc discharge was generated at atmospheric pressure in an air flow. The dynamics of the plasma column and tracer particles were recorded using two synchronized high-speed cameras. Whereas the data analysis for such systems has previously been performed in 2D (analyzing...... the single camera image), we provide here a 3D data analysis that includes 3D reconstructions of the plasma column and 3D particle tracking velocimetry based on discrete tomography methods. The 3D analysis, in particular, the determination of the 3D slip velocity between the plasma column and the gas flow......, gives more realistic insight into the convection cooling process. Additionally, with the determination of the 3D slip velocity and the 3D length of the plasma column, we give more accurate estimates for the drag force, the electric field strength, the power per unit length, and the radius...

  17. Measurements of 3D slip velocities and plasma column lengths of a gliding arc discharge

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Jiajian; Gao, Jinlong; Ehn, Andreas; Aldén, Marcus; Li, Zhongshan, E-mail: zhongshan.li@forbrf.lth.se, E-mail: alpers@ma.tum.de [Division of Combustion Physics, Lund University, P.O. Box 118, S-221 00 Lund (Sweden); Moseev, Dmitry [Max-Planck-Institut für Plasmaphysik, D-85748 Garching bei München (Germany); FOM Institute DIFFER, 3430 BE Nieuwegein (Netherlands); Kusano, Yukihiro [Department of Wind Energy, Section for Composites and Materials Mechanics, Technical University of Denmark, Risø Campus, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Salewski, Mirko [Department of Physics, Section for Plasma Physics and Fusion Energy, Technical University of Denmark, DK-2800 Kongens Lyngby (Denmark); Alpers, Andreas, E-mail: zhongshan.li@forbrf.lth.se, E-mail: alpers@ma.tum.de; Gritzmann, Peter; Schwenk, Martin [Zentrum Mathematik, Technische Universität München, D-85747 Garching bei München (Germany)

    2015-01-26

    A non-thermal gliding arc discharge was generated at atmospheric pressure in an air flow. The dynamics of the plasma column and tracer particles were recorded using two synchronized high-speed cameras. Whereas the data analysis for such systems has previously been performed in 2D (analyzing the single camera image), we provide here a 3D data analysis that includes 3D reconstructions of the plasma column and 3D particle tracking velocimetry based on discrete tomography methods. The 3D analysis, in particular, the determination of the 3D slip velocity between the plasma column and the gas flow, gives more realistic insight into the convection cooling process. Additionally, with the determination of the 3D slip velocity and the 3D length of the plasma column, we give more accurate estimates for the drag force, the electric field strength, the power per unit length, and the radius of the conducting zone of the plasma column.

  18. ABSOLUTE BUNCH LENGTH MEASUREMENTS AT THE ALS BY INCOHERENTSYNCHROTRON RADIATION FLUCTUATION ANALYSIS

    Energy Technology Data Exchange (ETDEWEB)

    Sannibale, Fernando; Zolotorev, Max S.; Filippetto, Daniele; Stupakov, Gennady V.

    2007-06-22

    By analysing the pulse to pulse intensity fluctuations ofthe radiation emitted by a charge particle in the incoherent part of thespectrum, it is possible to extract information about the spatialdistribution of the beam. At the Advanced Light Source (ALS) of theLawrence Berkeley National Laboratory, we have developed and tested asimple scheme based on this principle that allows for the absolutemeasurement of the bunch length. A description of the method and theexperimental results are presented.

  19. In Vivo Sarcomere Length Measurement in Whole Muscles during Passive Stretch and Twitch Contractions

    OpenAIRE

    Young, Kevin W.; Kuo, Bill P.-P.; O’Connor, Shawn M.; Radic, Stojan; Lieber, Richard L.

    2017-01-01

    Muscle force is dictated by micrometer-scale contractile machines called sarcomeres. Whole-muscle force drops from peak force production to zero with just a few micrometers of sarcomere length change. No current technology is able to capture adequate dynamic sarcomere data in vivo, and thus we lack fundamental data needed to understand human movement and movement disorders. Methods such as diffraction, endoscopy, and optical coherence tomography have been applied to muscle but are prohibitive...

  20. Validity and reliability of a portable gait analysis system for measuring spatiotemporal gait characteristics: comparison to an instrumented treadmill.

    Science.gov (United States)

    Donath, Lars; Faude, Oliver; Lichtenstein, Eric; Nüesch, Corina; Mündermann, Annegret

    2016-01-20

    Gait analysis serves as an important tool for clinicians and other health professionals to assess gait patterns related to functional limitations due to neurological or orthopedic conditions. The purpose of this study was to assess the validity of a body-worn inertial sensor system (RehaGait®) for measuring spatiotemporal gait characteristics compared to a stationary treadmill (Zebris) and the reliability of both systems at different walking speeds and slopes. Gait analysis was performed during treadmill walking at different speeds (habitual walking speed (normal speed); 15 % above normal walking speed; 15 % below normal walking speed) and slopes (0 % slope; 15 % slope) in 22 healthy participants twice 1 week apart. Walking speed, stride length, cadence and stride time were computed from the inertial sensor system and the stationary treadmill and compared using repeated measures analysis of variance. Effect sizes of differences between systems were assessed using Cohen's d, and limits of agreement and systematic bias were computed. The RehaGait® system slightly overestimated stride length (+2.7 %) and stride time (+0.8 %) and underestimate cadence (-1.5 %) with small effect sizes for all speeds and slopes (Cohen's d ≤ 0.44) except slow speed at 15 % slope (Cohen's d > 0.80). Walking speed obtained with the RehaGait® system closely matched the speed set on the treadmill tachometer. Intraclass correlation coefficients (ICC) were excellent for speed, cadence and stride time and for stride length at normal and fast speed at 0 % slope (ICC: .91-1.00). Good ICC values were found for stride length at slow speed at 0 % slope and all speeds at 15 % slope (ICC: .73-.90). Both devices had excellent reliability for most gait characteristics (ICC: .91-1.00) except good reliability for the RehaGait® for stride length at normal and fast speed at 0 % slope and at slow speed at 15 % slope (ICC: .80-.87). Larger limits of agreement for walking at 15

  1. Simultaneous Water Vapor and Dry Air Optical Path Length Measurements and Compensation with the Large Binocular Telescope Interferometer

    Science.gov (United States)

    Defrere, D.; Hinz, P.; Downey, E.; Boehm, M.; Danchi, W. C.; Durney, O.; Ertel, S.; Hill, J. M.; Hoffmann, W. F.; Mennesson, B.; hide

    2016-01-01

    The Large Binocular Telescope Interferometer uses a near-infrared camera to measure the optical path length variations between the two AO-corrected apertures and provide high-angular resolution observations for all its science channels (1.5-13 microns). There is however a wavelength dependent component to the atmospheric turbulence, which can introduce optical path length errors when observing at a wavelength different from that of the fringe sensing camera. Water vapor in particular is highly dispersive and its effect must be taken into account for high-precision infrared interferometric observations as described previously for VLTI/MIDI or the Keck Interferometer Nuller. In this paper, we describe the new sensing approach that has been developed at the LBT to measure and monitor the optical path length fluctuations due to dry air and water vapor separately. After reviewing the current performance of the system for dry air seeing compensation, we present simultaneous H-, K-, and N-band observations that illustrate the feasibility of our feed forward approach to stabilize the path length fluctuations seen by the LBTI nuller uses a near-infrared camera to measure the optical path length variations between the two AO-corrected apertures and provide high-angular resolution observations for all its science channels (1.5-13 microns). There is however a wavelength dependent component to the atmospheric turbulence, which can introduce optical path length errors when observing at a wavelength different from that of the fringe sensing camera. Water vapor in particular is highly dispersive and its effect must be taken into account for high-precision infrared interferometric observations as described previously for VLTI MIDI or the Keck Interferometer Nuller. In this paper, we describe the new sensing approach that has been developed at the LBT to measure and monitor the optical path length fluctuations due to dry air and water vapor separately. After reviewing the current

  2. [Vasa praevia diagnosis during transvaginal measurement of cervical length as preventing preterm delivery in the second quarter].

    Science.gov (United States)

    Belmonte-Andújar, L I; Fuentes-Rozalén, A M; Soler-Garcia, R M

    2016-03-01

    Vasa praevia is a rare pregnancy complication with a high fetal mortality when not diagnosed in the prenatal period. two cases of vasa praevia diagnosed during the second trimester ultrasound cervical measurement. We propose carry out further investigation about cost effectiveness of double vaginal screening (cervical length measurement and vasa praevia) during the second trimester morphology ultrasound. This implementation could allow to reduce the high mortality associated to this obstetric complication.

  3. Application of a Low-Energy Electron Beam as a Tool for ultrashort bunch length measurement in circular machines

    CERN Document Server

    Nikiforov, D A; Malyutin, D; Matveenko, A; Rusinov, K; Starostenko, A A

    2017-01-01

    A new diagnostic device designed for non-destructive ultrashort bunch length measurement is described. The operating principle of the device and the measuring technique are described. The possible scheme of arrangement of the device elements are described. The results of simulations of EBP application for different beams under investigation are presented. The quality requirements of the low energy testing beam are considered and resolving detector ability is determined.

  4. Correlation of Leukocyte Telomere Length Measurement Methods in Patients with Dyskeratosis Congenita and in Their Unaffected Relatives

    OpenAIRE

    Khincha, Payal P.; Dagnall, Casey L.; Hicks, Belynda; Jones, Kristine; Aviv, Abraham; Kimura, Masayuki; Katki, Hormuzd; Aubert, Geraldine; Giri, Neelam; Alter, Blanche P.; Savage, Sharon A.; Gadalla, Shahinaz M.

    2017-01-01

    Several methods have been employed to measure telomere length (TL) in human studies. It has been difficult to directly compare the results from these studies because of differences in the laboratory techniques and output parameters. We compared TL measurements (TLMs) by the three most commonly used methods, quantitative polymerase chain reaction (qPCR), flow cytometry with fluorescence in situ hybridization (flow FISH) and Southern blot, in a cohort of patients with the telomere biology disor...

  5. Length and volume of morphologically normal kidneys in Korean Children: Ultrasound measurement and estimation using body size

    International Nuclear Information System (INIS)

    Kim, Jun Hwee; Kim, Myung Joon; Lim, Sok Hwan; Lee, Mi Jung; Kim, Ji Eun

    2013-01-01

    To evaluate the relationship between anthropometric measurements and renal length and volume measured with ultrasound in Korean children who have morphologically normal kidneys, and to create simple equations to estimate the renal sizes using the anthropometric measurements. We examined 794 Korean children under 18 years of age including a total of 394 boys and 400 girls without renal problems. The maximum renal length (L) (cm), orthogonal anterior-posterior diameter (D) (cm) and width (W) (cm) of each kidney were measured on ultrasound. Kidney volume was calculated as 0.523 x L x D x W (cm 3 ). Anthropometric indices including height (cm), weight (kg) and body mass index (m 2 /kg) were collected through a medical record review. We used linear regression analysis to create simple equations to estimate the renal length and the volume with those anthropometric indices that were mostly correlated with the US-measured renal sizes. Renal length showed the strongest significant correlation with patient height (R2, 0.874 and 0.875 for the right and left kidneys, respectively, p < 0.001). Renal volume showed the strongest significant correlation with patient weight (R2, 0.842 and 0.854 for the right and left kidneys, respectively, p < 0.001). The following equations were developed to describe these relationships with an estimated 95% range of renal length and volume (R2, 0.826-0.884, p < 0.001): renal length = 2.383 + 0.045 x Height (± 1.135) and = 2.374 + 0.047 x Height (± 1.173) for the right and left kidneys, respectively; and renal volume 7.941 + 1.246 x Weight (± 15.920) and = 7.303 + 1.532 x Weight (± 18.704) for the right and left kidneys, respectively. Scatter plots between height and renal length and between weight and renal volume have been established from Korean children and simple equations between them have been developed for use in clinical practice.

  6. Coupling of relative intensity noise and pathlength noise to the length measurement in the optical metrology system of LISA Pathfinder

    Science.gov (United States)

    Wittchen, Andreas; the LPF Collaboration

    2017-05-01

    LISA Pathfinder is a technology demonstration mission for the space-based gravitational wave observatory, LISA. It demonstrated that the performance requirements for the interferometric measurement of two test masses in free fall can be met. An important part of the data analysis is to identify the limiting noise sources. [1] This measurement is performed with heterodyne interferometry. The performance of this optical metrology system (OMS) at high frequencies is limited by sensing noise. One such noise source is Relative Intensity Noise (RIN). RIN is a property of the laser, and the photodiode current generated by the interferometer signal contains frequency dependant RIN. From this electric signal the phasemeter calculates the phase change and laser power, and the coupling of RIN into the measurement signal depends on the noise frequency. RIN at DC, at the heterodyne frequency and at two times the heterodyne frequency couples into the phase. Another important noise at high frequencies is path length noise. To reduce the impact this noise is suppressed with a control loop. Path length noise not suppressed will couple directly into the length measurement. The subtraction techniques of both noise sources depend on the phase difference between the reference signal and the measurement signal, and thus on the test mass position. During normal operations we position the test mass at the interferometric zero, which is optimal for noise subtraction purposes. This paper will show results from an in-flight experiment where the test mass position was changed to make the position dependant noise visible.

  7. A volumetric approach to path-length measurements is essential when treating radiotherapy with modulated beams

    Energy Technology Data Exchange (ETDEWEB)

    Forde, Elizabeth, E-mail: eforde@tcd.ie [Discipline of Radiation Therapy, School of Medicine, Trinity College Dublin, Dublin (Ireland); Booth, Jeremy [Northern Sydney Cancer Centre, Royal North Shore Hospital, New South Wales (Australia); Leech, Michelle [Discipline of Radiation Therapy, School of Medicine, Trinity College Dublin, Dublin (Ireland)

    2014-07-01

    The established dosimetric benefits of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy have lead to their increased use in prostate radiotherapy. Complimenting these techniques, volumetric image guidance has supported increased positional accuracy. In addition, 3-dimensional image guidance has also allowed for assessment of potential dosimetric variation that can be attributed to a deformation of either internal or external structures, such as rectal distension or body contour. Compounding these issues is the variation of tissue density through which the new field position passes and also the variation of dose across a modulated beam. Despite the growing level of interest in this area, there are only a limited number of articles that examine the effect of a variation in beam path length, particularly across a modulated field. IMRT and volumetric-modulated radiation therapy (VMAT) fields are dynamic in nature, and the dose gradient within these fields is variable. Assessment of variation of path length away from the beam's central axis and across the entire field is vital where there is considerable variation of dose within the field, such as IMRT and VMAT. In these cases, reliance on the traditional central axis to focus skin distances is no longer appropriate. This article discusses these more subtle challenges that may have a significant clinical effect if left unrecognized and undervalued.

  8. Correlation of intra-articular osseous measurements with posterior cruciate ligament length on MRI scans.

    LENUS (Irish Health Repository)

    Orakzai, S H

    2010-01-01

    Six patients with a clinical diagnosis of chronic posterior cruciate ligament (PCL) rupture, based on a positive posterior drawer test, had a normal appearance of the PCL on an MRI scan. It is postulated that the PCL had been ruptured but healed in a lengthened state. 12 volunteers with no history of knee trauma underwent an MRI scan of the knee. In this control group (n = 12), there was a close correlation between the lateral femoral condylar width in the sagittal plane and the PCL length, with a ratio of 2:1 (95% confidence interval (CI) = 1.817-2.095). In the clinically abnormal group (n = 6), the ratio was 1.49:1 (95% CI = 1.206-1.782) (p< 0.0005). In conclusion, the ratio of the lateral femoral condylar width in the sagittal plane to the PCL length is a useful index for diagnosing PCL attenuation and lengthening in the presence of a normal morphological MR appearance.

  9. Isotopic fractionation in proteins as a measure of hydrogen bond length

    Energy Technology Data Exchange (ETDEWEB)

    McKenzie, Ross H., E-mail: r.mckenzie@uq.edu.au [School of Mathematics and Physics, University of Queensland, Brisbane 4072 (Australia); Athokpam, Bijyalaxmi; Ramesh, Sai G. [Department of Inorganic and Physical Chemistry, Indian Institute of Science, Bangalore 560 012 (India)

    2015-07-28

    If a deuterated molecule containing strong intramolecular hydrogen bonds is placed in a hydrogenated solvent, it may preferentially exchange deuterium for hydrogen. This preference is due to the difference between the vibrational zero-point energy for hydrogen and deuterium. It is found that the associated fractionation factor Φ is correlated with the strength of the intramolecular hydrogen bonds. This correlation has been used to determine the length of the H-bonds (donor-acceptor separation) in a diverse range of enzymes and has been argued to support the existence of short low-barrier H-bonds. Starting with a potential energy surface based on a simple diabatic state model for H-bonds, we calculate Φ as a function of the proton donor-acceptor distance R. For numerical results, we use a parameterization of the model for symmetric O–H⋯O bonds [R. H. McKenzie, Chem. Phys. Lett. 535, 196 (2012)]. We consider the relative contributions of the O–H stretch vibration, O–H bend vibrations (both in plane and out of plane), tunneling splitting effects at finite temperature, and the secondary geometric isotope effect. We compare our total Φ as a function of R with NMR experimental results for enzymes, and in particular with an earlier model parametrization Φ(R), used previously to determine bond lengths.

  10. A volumetric approach to path-length measurements is essential when treating radiotherapy with modulated beams.

    Science.gov (United States)

    Forde, Elizabeth; Booth, Jeremy; Leech, Michelle

    2014-01-01

    The established dosimetric benefits of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy have lead to their increased use in prostate radiotherapy. Complimenting these techniques, volumetric image guidance has supported increased positional accuracy. In addition, 3-dimensional image guidance has also allowed for assessment of potential dosimetric variation that can be attributed to a deformation of either internal or external structures, such as rectal distension or body contour. Compounding these issues is the variation of tissue density through which the new field position passes and also the variation of dose across a modulated beam. Despite the growing level of interest in this area, there are only a limited number of articles that examine the effect of a variation in beam path length, particularly across a modulated field. IMRT and volumetric-modulated radiation therapy (VMAT) fields are dynamic in nature, and the dose gradient within these fields is variable. Assessment of variation of path length away from the beam׳s central axis and across the entire field is vital where there is considerable variation of dose within the field, such as IMRT and VMAT. In these cases, reliance on the traditional central axis to focus skin distances is no longer appropriate. This article discusses these more subtle challenges that may have a significant clinical effect if left unrecognized and undervalued. Copyright © 2014 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  11. The Accuracy of the Digital imaging system and the frequency dependent type apex locator in root canal length measurement

    International Nuclear Information System (INIS)

    Lee, Byoung Rib; Park, Chang Seo

    1998-01-01

    In order to achieve a successful endodontic treatment, root canals must be obturated three-dimensionally without causing any damage to apical tissues. Accurate length determination of the root canal is critical in this case. For this reason, I've used the conventional periapical radiography, Digora (digital imaging system) and Root ZX (the frequency dependent type apex locator) to measure the length of the canal and compare it with the true length obtained by cutting the tooth in half and measuring the length between the occlusal surface and the apical foramen. From the information obtained by these measurements, I was able to evaluate the accuracy and clinical usefulness of each systems, whether the thickness of files used in endodontic therapy has any effect on the measuring systems was also evaluated in an effort to simplify the treatment planning phase of endodontic treatment. 29 canals of 29 sound premolars were measured with no 15, no 20, no 25 files by 3 different dentists each using the periapical radiography, Digora and Root ZX. The measurements were then compared with the true length. The results were as follows ; 1. In comparing mean discrepancies between measurements obtained by using periapical radiography (mean error : -0.449 ± 0.444 mm), Digora (mean error : -0.417 ± 0.415 mm) and Root ZX (mean error : 0.123 ± 0.458 mm) with true length, periapical radiography and Digora system had statistically significant differences (p 0.05). 2. By subtracting values obtained by using periapical radiography, Digora and Root ZX from the true length and making a distribution table of their absolute values, the following analysis was possible. In the case of periapical film, 140 out of 261 (53.6%) were clinically acceptable satisfying the margin of error of less than 0.5 mm, 151 out of 261 (53,6%) were acceptable in the Digora system while Root ZX had 197 out of 261 (75.5%) within the limits of 0.5 mm margin of error. 3. In determining whether the thickness of

  12. The Accuracy of the Digital imaging system and the frequency dependent type apex locator in root canal length measurement

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byoung Rib; Park, Chang Seo [Dept. of Dental Radiology, College of Dentistry, Yensei University, Seoul (Korea, Republic of)

    1998-08-15

    In order to achieve a successful endodontic treatment, root canals must be obturated three-dimensionally without causing any damage to apical tissues. Accurate length determination of the root canal is critical in this case. For this reason, I've used the conventional periapical radiography, Digora (digital imaging system) and Root ZX (the frequency dependent type apex locator) to measure the length of the canal and compare it with the true length obtained by cutting the tooth in half and measuring the length between the occlusal surface and the apical foramen. From the information obtained by these measurements, I was able to evaluate the accuracy and clinical usefulness of each systems, whether the thickness of files used in endodontic therapy has any effect on the measuring systems was also evaluated in an effort to simplify the treatment planning phase of endodontic treatment. 29 canals of 29 sound premolars were measured with no 15, no 20, no 25 files by 3 different dentists each using the periapical radiography, Digora and Root ZX. The measurements were then compared with the true length. The results were as follows; 1. In comparing mean discrepancies between measurements obtained by using periapical radiography (mean error : -0.449 {+-} 0.444 mm), Digora (mean error : -0.417 {+-} 0.415 mm) and Root ZX (mean error : 0.123 {+-} 0.458 mm) with true length, periapical radiography and Digora system had statistically significant differences (p<0.05) in most cases while root zx showed none (p>0.05). 2. By subtracting values obtained by using periapical radiography, Digora and Root ZX from the true length and making a distribution table of their absolute values, the following analysis was possible. In the case of periapical film, 140 out of 261 (53.6%) were clinically acceptable satisfying the margin of error of less than 0.5 mm, 151 out of 261 (53,6%) were acceptable in the Digora system while Root ZX had 197 out of 261 (75.5%) within the limits of 0.5 mm

  13. Voxel effects within digital images of trabecular bone and their consequences on chord-length distribution measurements

    International Nuclear Information System (INIS)

    Rajon, D.A.; Shah, A.P.; Watchman, C.J.; Bolch, W.E.; Jokisch, D.W.; Patton, P.W.

    2002-01-01

    Chord-length distributions through the trabecular regions of the skeleton have been investigated since the early 1960s. These distributions have become important features for bone marrow dosimetry; as such, current models rely on the accuracy of their measurements. Recent techniques utilize nuclear magnetic resonance (NMR) microscopy to acquire 3D images of trabecular bone that are then used to measure 3D chord-length distributions by Monte Carlo methods. Previous studies have shown that two voxel effects largely affect the acquisition of these distributions within digital images. One is particularly pertinent as it dramatically changes the shape of the distribution and reduces its mean. An attempt was made to reduce this undesirable effect and good results were obtained for a single-sphere model using minimum acceptable chord (MAC) methods (Jokisch et al 2001 Med. Phys. 28 1493-504). The goal of the present work is to extend the study of these methods to more general models in order to better quantify their consequences. First, a mathematical model of a trabecular bone sample was used to test the usefulness of the MAC methods. The results showed that these methods were not efficient for this simulated bone model. These methods were further tested on a single voxelized sphere over a large range of voxel sizes. The results showed that the MAC methods are voxel-size dependent and overestimate the mean chord length for typical resolutions used with NMR microscopy. The study further suggests that bone and marrow chord-length distributions currently utilized in skeletal dosimetry models are most likely affected by voxel effects that yield values of mean chord length lower than their true values. (author)

  14. Modeling the effect of probe force on length measurements on polymer parts

    DEFF Research Database (Denmark)

    Mohammadi, Ali; Sonne, Mads Rostgaard; Dalla Costa, Giuseppe

    2016-01-01

    Measurement uncertainty at micrometer level is in the future going to be very common in dimensional measurements on polymer parts. Accurate dimensional measurement of polymer parts is becoming a key and common practice in the industry, especially when micrometer tolerances are required. When...... numerically. Both analytical and numerical approaches were compared with the experimental results. The results showed that the numerical model was able to predict the deformation of the polymer part due to different probe forces. Furthermore it was shown, that the probe force should be taking into account...... when measurement with a few micrometer accuracy should be performed on thin walled polymer parts....

  15. 'Length'at Length

    Indian Academy of Sciences (India)

    Admin

    He was interested to know how `large' is the set of numbers x for which the series is convergent. Here large refers to its length. But his set is not in the class ♢. Here is another problem discussed by Borel. Consider .... have an infinite collection of pairs of new shoes and want to choose one shoe from each pair. We have an ...

  16. The measurement of cholinesterase activities as a biomarker in chub (Leuciscus cephalus): the fish length should not be ignored

    Energy Technology Data Exchange (ETDEWEB)

    Flammarion, P.; Noury, P.; Garric, J

    2002-12-01

    The fish length should be considered within the statistical analysis of ChE activities in chub species. - Biomarkers are early warning systems of the exposure of aquatic organisms to pollutants. Among them, the measurement of the cholinesterase (ChE) activities in fish muscle is a biomarker of the exposure to organophosphosphates and carbamates pesticides. As such it has been used in numerous field studies both in marine and continental waters. Cyprinids (chub, Leuciscus cephalus) were sampled in river sites (France) in relatively clean and polluted areas. We performed the statistical analysis of the ChE activities and we generally observed a statistical relationship between ChE activities and fish length, the larger fish having the lower ChE activities. We concluded that the great majority of the significant differences in ChE activities between sites could be due in fact to differences in fish length between field samples. We stress the importance of taking into account the fish length whenever differences in ChE levels between field sites must be interpreted.

  17. Project Stride: An Equine-Assisted Intervention to Reduce Symptoms of Social Anxiety in Young Women.

    Science.gov (United States)

    Alfonso, Sarah V; Alfonso, Lauren A; Llabre, Maria M; Fernandez, M Isabel

    2015-01-01

    Although there is evidence supporting the use of equine-assisted activities to treat mental disorders, its efficacy in reducing signs and symptoms of social anxiety in young women has not been examined. We developed and pilot tested Project Stride, a brief, six-session intervention combining equine-assisted activities and cognitive-behavioral strategies to reduce symptoms of social anxiety. A total of 12 women, 18-29 years of age, were randomly assigned to Project Stride or a no-treatment control. Participants completed the Liebowitz Social Anxiety Scale at baseline, immediate-post, and 6 weeks after treatment. Project Stride was highly acceptable and feasible. Compared to control participants, those in Project Stride had significantly greater reductions in social anxiety scores from baseline to immediate-post [decrease of 24.8 points; t (9) = 3.40, P = .008)] and from baseline to follow-up [decrease of 31.8 points; t (9) = 4.12, P = .003)]. These findings support conducting a full-scale efficacy trial of Project Stride. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Actively cooled pump limiters and power scrape-off length measurements in Tore-Supra

    International Nuclear Information System (INIS)

    Guilhem, D.; Seigneur, A.; Chappuis, P.; Chatelier, M.; DeMichelis, C.; Deschamps, P.; Grosman, A.; Hess, W.; Lecoustey, P.; Loarer, T.; Poutchy, L.; Schlosser, J.

    1992-01-01

    TORE-SUPRA is a superconducting Tokamak aimed at studying long plasma pulses (>30 s). It is equipped with two types of pump limiters (PL). A provisional type, semi-inertially cooled between shots, has been used for plasma scrape off characterization. The e-folding length λq for power deposition on these components has been unfolded (1.0cm 19 m -3 19 m -3 ), of power level up to 4 MW and of toroidal magnetic field (1.5 T -1/2 ). The second type used for long pulse operation, is actively cooled during shots, its thermal time constant being less than 2 seconds. Experiments using this ITER relevant technology are presented. Three of the actively cooled limiters have been successfully tested in a steady state regime with a surface temperature less than 1000 deg C (I p =1.6 MA). The design value for power removal on this type of limiters has been obtained. Peak power fluxes of 10 MW/m 2 have been estimated. This represents a breakthrough for high heat flux components since critical heat flux and burnout with subcooled flow boiling are major aspects for this kind of design

  19. An evaluation of deep-sea benthic megafauna length measurements obtained with laser and stereo camera methods

    Science.gov (United States)

    Dunlop, Katherine M.; Kuhnz, Linda A.; Ruhl, Henry A.; Huffard, Christine L.; Caress, David W.; Henthorn, Richard G.; Hobson, Brett W.; McGill, Paul; Smith, Kenneth L.

    2015-02-01

    The 25 year time-series collected at Station M, ~4000 m on the Monterey Deep-sea Fan, has substantially improved understanding of the role of the deep-ocean benthic environment in the global carbon cycle. However, the role of deep-ocean benthic megafauna in carbon bioturbation, remineralization and sequestration is relatively unknown. It is important to gather both accurate and precise measurements of megafaunal community abundance, size distribution and biomass to further define their role in deep-sea carbon cycling and possible sequestration. This study describes initial results from a stereo camera system attached to a remotely operated vehicle and analyzed using the EventMeasure photogrammetric measurement software to estimate the density, length and biomass of 10 species of mobile epibenthic megafauna. Stereo length estimates were compared to those from a single video camera system equipped with sizing lasers and analyzed using the Monterey Bay Aquarium Research Institute's Video Annotation and Reference System. Both camera systems and software were capable of high measurement accuracy and precision (megafauna species studied. The stereo image analysis process took substantially longer than the video analysis and the value of the EventMeasure software tool would be improved with developments in analysis automation. The stereo system is less influenced by object orientation and height, and is potentially a useful tool to be mounted on an autonomous underwater vehicle and for measuring deep-sea pelagic animals where the use of lasers is not feasible.

  20. Acoustic Scattering by Axisymmetric Finite-Length Bodies with Application to Fish: Measurement and Modeling

    National Research Council Canada - National Science Library

    Reeder, D

    2002-01-01

    ... laboratory acoustic measurements. A general acoustic scattering model is developed that is accurate and numerically efficient for a wide range of frequencies, angles of orientation, irregular axisymmetric shapes and boundary...

  1. Q-FISH measurement of hepatocyte telomere lengths in donor liver and graft after pediatric living-donor liver transplantation: donor age affects telomere length sustainability.

    Directory of Open Access Journals (Sweden)

    Youichi Kawano

    Full Text Available Along with the increasing need for living-donor liver transplantation (LDLT, the issue of organ shortage has become a serious problem. Therefore, the use of organs from elderly donors has been increasing. While the short-term results of LDLT have greatly improved, problems affecting the long-term outcome of transplant patients remain unsolved. Furthermore, since contradictory data have been reported with regard to the relationship between donor age and LT/LDLT outcome, the question of whether the use of elderly donors influences the long-term outcome of a graft after LT/LDLT remains unsettled. To address whether hepatocyte telomere length reflects the outcome of LDLT, we analyzed the telomere lengths of hepatocytes in informative biopsy samples from 12 paired donors and recipients (grafts of pediatric LDLT more than 5 years after adult-to-child LDLT because of primary biliary atresia, using quantitative fluorescence in situ hybridization (Q-FISH. The telomere lengths in the paired samples showed a robust relationship between the donor and grafted hepatocytes (r = 0.765, p = 0.0038, demonstrating the feasibility of our Q-FISH method for cell-specific evaluation. While 8 pairs showed no significant difference between the telomere lengths for the donor and the recipient, the other 4 pairs showed significantly shorter telomeres in the recipient than in the donor. Multiple regression analysis revealed that the donors in the latter group were older than those in the former (p = 0.001. Despite the small number of subjects, this pilot study indicates that donor age is a crucial factor affecting telomere length sustainability in hepatocytes after pediatric LDLT, and that the telomeres in grafted livers may be elongated somewhat longer when the grafts are immunologically well controlled.

  2. Path-length-resolved measurements of multiple scattered photons in static and dynamic turbid media using phase-modulated low-coherence interferometry

    NARCIS (Netherlands)

    Varghese, Babu; Rajan, Vinayakrishnan; van Leeuwen, Ton G.; Steenbergen, Wiendelt

    2007-01-01

    In optical Doppler measurements, the path length of the light is unknown. To facilitate quantitative measurements, we develop a phase-modulated Mach-Zehnder interferometer with separate fibers for illumination and detection. With this setup, path-length-resolved dynamic light scattering measurements

  3. Establishment of a method to measure length of the ulnar nerve and standardize F-wave values in clinically normal beagles.

    Science.gov (United States)

    Hirasawa, Shun; Shimizu, Miki; Marui, Yuumi; Kishimoto, Miori; Okuno, Seiichi

    2014-12-01

    We designed a new method of measuring the length of the ulnar nerve and determining standard values for F-wave parameters of the ulnar nerve in clinically normal beagles. Nerve length must be precisely measured to determine F-wave latency and conduction velocity. The length of the forelimb has served as the length of the ulnar nerve for F-wave assessments, but report indicates that F-wave latency is proportional to the length of the pathway traveled by nerve impulses. Therefore, we measured the surface distance from a stimulus point to the spinous process of the first thoracic vertebra (nerve length 1) and the anterior horn of the scapula (nerve length 2) as landmarks through the olecranon and the shoulder blade acromion. The correlation coefficients between the shortest F-wave latency and the length of nerves 1, 2 or the forelimb were 0.61, 0.7 and 0.58. Nerve length 2 generated the highest value. Furthermore, the anterior horn of the scapula was easily palpated in any dog regardless of well-fed body. We concluded that nerve length 2 was optimal for measuring the length of the ulnar nerve.

  4. Path length dependence of jet quenching measured with ALICE at the LHC

    NARCIS (Netherlands)

    Bertens, R.A.

    2016-01-01

    Jets are used to probe the quark-gluon plasma (QGP) that is created in heavy-ion collisions, by using the fact that medium-induced parton energy loss from elastic and radiative interactions between partons and the QGP lead to a modification of the measured jet spectrum. The dependence of the energy

  5. Life expectancy: complex measures of the length and the health related quality of life

    Directory of Open Access Journals (Sweden)

    Daniele Spizzichino

    2008-06-01

    Full Text Available

    Background: Life expectancy is one of the most frequently used indicators to assess mortality and the health of a population. It is a synthetic measure of mortality, which has the advantage of allowing for comparisons over time and between different groups, while eliminating the influence of the age structure of the population. Life expectancy has the advantage of being very easy to understand, although it needs to be interpreted within the context of the complex system of hypothesis that generates it. This is even more important for health expectancies and health gap measures, which are synthetic indicators that take into account both survival and health condition of a population.

    Methods: It is given a description of the most frequently used methods to calculate life expectancy, health expectancies and health gap measures. Measures of health expectancy are disability free life expectancy and healthy life expectancy. As health gap measures, frequently are used DALYs (Disability Adjusted Life Years.

    Discussion: There are various bodies and central government agencies that either have management data or carry out statistical systematic surveys and disability surveys. Statistically speaking, the worst aspect of this scenario is that it creates confusion and uncertainty among the end users of this data, namely the policy makers. At an international level the statistical data on disability is scarcely comparable among countries, despite huge efforts on the part of international organisations to harmonize classifications and definitions of disability.

    Results and Conclusions: There are several methods to compute life expectancy, each of these has some advantages and some disadvantages. Usually life expectancy is used also to account for the health status of population. Actually with the growing role of chronic and degenerative diseases, the increased number of

  6. Cervical length measurement in nulliparous women at term by ultrasound & its relationship to spontaneous onset of labour.

    Science.gov (United States)

    Mukherji, Joydev; Bhadra, Avishek; Ghosh, Suhas Kumar; Hazra, Avijit; Anant, Monika; Bhattacharya, Subir Kumar; Das, Bibekananda; Banu, Shabnam

    2017-10-01

    Data on serial cervical length (CL) measurements in pregnancy at term to predict spontaneous labour onset are scarce and conflicting. This study was conducted to observe CL changes preceding spontaneous onset of labour, by serial transvaginal sonography (TVS) and transabdominal sonography (TAS), in nulliparous Indian women near term. Only nulliparous women with a singleton foetus in cephalic presentation and who confirmed their gestational age were recruited. Sonographic CL measurements were taken at weekly intervals from 36 wk gestation onwards by a single ultrasonologist. Transabdominal and transvaginal measurements were undertaken using the suitable transducer probes with the women in the supine position. A total of 104 women with spontaneous onset of labour were evaluated. There was substantial variation in CL measurements, both by TVS and by TAS, from 36 to 40 wk gestation, although the two sets of measurements correlated closely. Mean CL changed significantly over the last three weeks before delivery. However, only one-third of the women showed CL change of >5 mm per week in the last three weeks. There was poor correlation between gestational age at delivery and the last measured CL, either by TVS or TAS. Length >3.1 mm, measured by TVS at 38 wk gestation, predicted post-dated pregnancy to a limited extent. Inter-individual variations in CL and in CL changes were large. Thus, it was not practical to predict spontaneous onset of labour by sonographic CL measurement near term. Post-dated pregnancy may be predicted with limited success. Further studies should explore other parameters, in addition to CL.

  7. Optical absorption coefficient and minority carrier diffusion length measurements in low-cost silicon solar cell material

    Energy Technology Data Exchange (ETDEWEB)

    Swimm, R.T.; Dumas, K.A.

    1982-11-01

    The optical absorption coefficient of silicon solar cell material grown by three low-cost growth methods was measured in the wavelength interval 0.8< or =lambda< or =1.0 ..mu..m, the wavelength region of interest in surface photovoltage measurements of the minority carrier diffusion length. The square root of the absorption coefficient was found to vary linearly with photon energy over the wavelengths studied, and the measured data agree with a linear empirical fit to within 0.5% RMS. The absorption coefficients obtained are slightly lower than those reported by Runyan, with the greatest disagreement at long wavelengths. Minority carrier diffusion lengths computed using the present absorption coefficients are approximately 16% greater than those calculated using Runyan's data. Excellent sample-to-sample agreement within and between lots indicates that for two of the growth methods studied, material quality as judged by optical properties has not been sacrificed by the use of low-cost growth methods. Samples grown by the third growth method studied showed measurably poorer optical quality.

  8. Noise Suppression on the Tunable Laser for Precise Cavity Length Displacement Measurement

    Czech Academy of Sciences Publication Activity Database

    Šmíd, Radek; Čížek, Martin; Mikel, Břetislav; Hrabina, Jan; Lazar, Josef; Číp, Ondřej

    2016-01-01

    Roč. 16, č. 9 (2016), 1428:1-11 ISSN 1424-8220 R&D Projects: GA ČR(CZ) GPP102/12/P962; GA ČR GB14-36681G; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : Fabry-Perot cavity * unbalance Michelson interferometer * noise suppression * heterodyne interferometry * displacement measurement Subject RIV: BH - Optics, Masers, Lasers Impact factor: 2.677, year: 2016

  9. Development of a Data Reduction Algorithm for Optical Wide Field Patrol (OWL) II: Improving Measurement of Lengths of Detected Streaks

    Science.gov (United States)

    Park, Sun-Youp; Choi, Jin; Roh, Dong-Goo; Park, Maru; Jo, Jung Hyun; Yim, Hong-Suh; Park, Young-Sik; Bae, Young-Ho; Park, Jang-Hyun; Moon, Hong-Kyu; Choi, Young-Jun; Cho, Sungki; Choi, Eun-Jung

    2016-09-01

    As described in the previous paper (Park et al. 2013), the detector subsystem of optical wide-field patrol (OWL) provides many observational data points of a single artificial satellite or space debris in the form of small streaks, using a chopper system and a time tagger. The position and the corresponding time data are matched assuming that the length of a streak on the CCD frame is proportional to the time duration of the exposure during which the chopper blades do not obscure the CCD window. In the previous study, however, the length was measured using the diagonal of the rectangle of the image area containing the streak; the results were quite ambiguous and inaccurate, allowing possible matching error of positions and time data. Furthermore, because only one (position, time) data point is created from one streak, the efficiency of the observation decreases. To define the length of a streak correctly, it is important to locate the endpoints of a streak. In this paper, a method using a differential convolution mask pattern is tested. This method can be used to obtain the positions where the pixel values are changed sharply. These endpoints can be regarded as directly detected positional data, and the number of data points is doubled by this result.

  10. An Experimental Measurement on Laminar Burning Velocities and Markstein Length of Iso-Butane-Air Mixtures at Ambient Conditions

    Directory of Open Access Journals (Sweden)

    Yousif Alaeldeen Altag

    2016-01-01

    Full Text Available In the present work, experimental investigation on laminar combustion of iso-butane-air mixtures was conducted in constant volume explosion vessel. The experiments were conducted at wide range of equivalence ratios ranging between Ф = 0.6 and 1.4 and atmospheric pressure of 0.1 MPa and ambient temperature of 303K. Using spherically expanding flame method, flame parameters including stretched, unstretched flame propagation speeds, laminar burning velocities and Markstein length were calculated. For laminar burning velocities the method of error bars of 95% confidence level was applied. In addition, values of Markstein lengths were measured in wide range of equivalence ratios to study the influence of stretch rate on flame instability and burning velocity. It was found that the stretched flame speed and laminar burning velocities increased with equivalence ratios and the peak value was obtained at equivalence ratio of Ф = 1.1. The Markstein length decreased with the increases in equivalence ratios, which indicates that the diffusion thermal flame instability increased at high equivalence ratios in richer mixture side. However, the total deviations in the laminar burning velocities have discrepancies of 1.2-2.9% for all investigated mixtures.

  11. The effects of social status on biological aging as measured by white-blood-cell telomere length.

    Science.gov (United States)

    Cherkas, L F; Aviv, A; Valdes, A M; Hunkin, J L; Gardner, J P; Surdulescu, G L; Kimura, M; Spector, T D

    2006-10-01

    Low socio-economic status (SES) is associated with a shortened life expectancy, but its effect on aging is unknown. The rate of white-blood-cell (WBC) telomere attrition may be a biological indicator of human aging. We tested the hypothesis that SES is associated with telomere attrition independent of known risk factors influencing the aging process. We studied 1552 female twins. A venous blood sample was taken from each twin and isolated WBCs used for extraction of DNA. Terminal restriction fragment length (TRFL) was measured. Questionnaire data were collected on occupation, education, income, smoking, exercise, height and weight. Standard multiple linear regression and multivariate analyses of variance tested for associations between SES and TRFL, adjusting for covariates. A discordant twin analysis was conducted on a subset to verify findings. WBC telomere length was highly variable but significantly shorter in lower SES groups. The mean difference in TRFL between nonmanual and manual SES groups was 163.2 base pairs (bp) of which 22.9 bp (approximately 14%) was accounted for by body mass index, smoking and exercise. Comparison of TRFL in the 17 most discordant SES twin pairs confirmed this difference. Low SES, in addition to the harmful effects of smoking, obesity and lack of exercise, appears to have an impact on telomere length.

  12. Assessing Stride Variables and Vertical Stiffness with GPS-Embedded Accelerometers: Preliminary Insights for the Monitoring of Neuromuscular Fatigue on the Field

    Directory of Open Access Journals (Sweden)

    Martin Buchheit, Andrew Gray, Jean-Benoit Morin

    2015-12-01

    Full Text Available The aim of the present study was to examine the ability of a GPS-imbedded accelerometer to assess stride variables and vertical stiffness (K, which are directly related to neuromuscular fatigue during field-based high-intensity runs. The ability to detect stride imbalances was also examined. A team sport player performed a series of 30-s runs on an instrumented treadmill (6 runs at 10, 17 and 24 km·h-1 with or without his right ankle taped (aimed at creating a stride imbalance, while wearing on his back a commercially-available GPS unit with an embedded 100-Hz tri-axial accelerometer. Contact (CT and flying (FT time, and K were computed from both treadmill and accelerometers (Athletic Data Innovations data. The agreement between treadmill (criterion measure and accelerometer-derived data was examined. We also compared the ability of the different systems to detect the stride imbalance. Biases were small (CT and K and moderate (FT. The typical error of the estimate was trivial (CT, small (K and moderate (FT, with nearly perfect (CT and K and large (FT correlations for treadmill vs. accelerometer. The tape induced very large increase in the right - left foot ∆ in CT, FT and K measured by the treadmill. The tape effect on CT and K ∆ measured with the accelerometers were also very large, but of lower magnitude than with the treadmill. The tape effect on accelerometer-derived ∆ FT was unclear. Present data highlight the potential of a GPS-embedded accelerometer to assess CT and K during ground running.

  13. Assessing Stride Variables and Vertical Stiffness with GPS-Embedded Accelerometers: Preliminary Insights for the Monitoring of Neuromuscular Fatigue on the Field.

    Science.gov (United States)

    Buchheit, Martin; Gray, Andrew; Morin, Jean-Benoit

    2015-12-01

    The aim of the present study was to examine the ability of a GPS-imbedded accelerometer to assess stride variables and vertical stiffness (K), which are directly related to neuromuscular fatigue during field-based high-intensity runs. The ability to detect stride imbalances was also examined. A team sport player performed a series of 30-s runs on an instrumented treadmill (6 runs at 10, 17 and 24 km·h(-1)) with or without his right ankle taped (aimed at creating a stride imbalance), while wearing on his back a commercially-available GPS unit with an embedded 100-Hz tri-axial accelerometer. Contact (CT) and flying (FT) time, and K were computed from both treadmill and accelerometers (Athletic Data Innovations) data. The agreement between treadmill (criterion measure) and accelerometer-derived data was examined. We also compared the ability of the different systems to detect the stride imbalance. Biases were small (CT and K) and moderate (FT). The typical error of the estimate was trivial (CT), small (K) and moderate (FT), with nearly perfect (CT and K) and large (FT) correlations for treadmill vs. accelerometer. The tape induced very large increase in the right - left foot ∆ in CT, FT and K measured by the treadmill. The tape effect on CT and K ∆ measured with the accelerometers were also very large, but of lower magnitude than with the treadmill. The tape effect on accelerometer-derived ∆ FT was unclear. Present data highlight the potential of a GPS-embedded accelerometer to assess CT and K during ground running. Key pointsGPS-embedded tri-axial accelerometers may be used to assess contact time and vertical stiffness during ground running.These preliminary results open new perspective for the field monitoring of neuromuscular fatigue and performance in run-based sports.

  14. LEARNING ONE-DIGIT DECIMAL NUMBERS BY MEASUREMENT AND GAME PREDICTING LENGTH

    Directory of Open Access Journals (Sweden)

    Puji Astuti

    2014-01-01

    Full Text Available This paper aims to describe how students develop understanding of one-digit decimals. To achieve the aim, Local Instruction Theory (LIT about the process of learning decimals and the means designed to support that learning are developed. Along with this idea, the framework of Realistic Mathematics Education (RME is proposed. Based on the aim, design research methodology is used. This paper discusses learning activities of three meetings from teaching experiment of the focus group students of the fourth grade elementary school in Surabaya: SDIT Al Ghilmani. The data indicated that the learning activities promoted the students’ understanding of one-digit decimal numbers.Keyword: measurement, decimal numbers, number line DOI: http://dx.doi.org/10.22342/jme.5.1.1447.35-46

  15. Effect of working length measurement by electronic apex locator or digital radiography on postoperative pain: a randomized clinical trial.

    Science.gov (United States)

    Kara Tuncer, Aysun; Gerek, Müzeyyen

    2014-01-01

    The aim of this study was to evaluate the effect of working length determination methods, electronic apex locator and digital radiography, on postoperative pain. Two hundred twenty patients with asymptomatic single-rooted vital teeth were randomly assigned to 2 groups according to the method used for working length determination, the radiographic group and the electronic apex locator group. After working length determination, chemomechanical preparation was performed in a crown-down technique with ProTaper instruments. A master cone radiograph was taken. Canals were obturated with gutta-percha and sealer by using a lateral compaction technique. Postoperative pain was assessed after 4, 6, 12, 24, and 48 hours by using a 4-point pain intensity scale. In addition, patients were asked to record the number of days necessary to achieve complete pain resolution. Postoperative pain during the 4-hour to 48-hour interval studied was not significantly different (P > .05) between groups. The mean times for pain dissipation in the radiographic and electronic apex locator groups were 3.37 ± 2.79 and 3.88 ± 3.34 days, respectively. The difference between groups was not statistically significant (P > .05). There is no difference in postoperative pain between working length measurement methods by using an electronic apex locator or digital radiography. The reduced exposure to radiation by using apex locator may be a factor that influences a dentist's decision to choose the electronic apex locator over radiography. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. Axial Length Variation Impacts on Superficial Retinal Vessel Density and Foveal Avascular Zone Area Measurements Using Optical Coherence Tomography Angiography.

    Science.gov (United States)

    Sampson, Danuta M; Gong, Peijun; An, Di; Menghini, Moreno; Hansen, Alex; Mackey, David A; Sampson, David D; Chen, Fred K

    2017-06-01

    To evaluate the impact of image magnification correction on superficial retinal vessel density (SRVD) and foveal avascular zone area (FAZA) measurements using optical coherence tomography angiography (OCTA). Participants with healthy retinas were recruited for ocular biometry, refraction, and RTVue XR Avanti OCTA imaging with the 3 × 3-mm protocol. The foveal and parafoveal SRVD and FAZA were quantified with custom software before and after correction for magnification error using the Littman and the modified Bennett formulae. Relative changes between corrected and uncorrected SRVD and FAZA were calculated. Forty subjects were enrolled and the median (range) age of the participants was 30 (18-74) years. The mean (range) spherical equivalent refractive error was -1.65 (-8.00 to +4.88) diopters and mean (range) axial length was 24.42 mm (21.27-28.85). Images from 13 eyes were excluded due to poor image quality leaving 67 for analysis. Relative changes in foveal and parafoveal SRVD and FAZA after correction ranged from -20% to +10%, -3% to +2%, and -20% to +51%, respectively. Image size correction in measurements of foveal SRVD and FAZA was greater than 5% in 51% and 74% of eyes, respectively. In contrast, 100% of eyes had less than 5% correction in measurements of parafoveal SRVD. Ocular biometry should be performed with OCTA to correct image magnification error induced by axial length variation. We advise caution when interpreting interocular and interindividual comparisons of SRVD and FAZA derived from OCTA without image size correction.

  17. On the frequency distributions per unit area of the projected and etchable lengths of surface-intersecting fission tracks: influences of track revelation, observation and measurement

    CERN Document Server

    Jonckheere, R

    1999-01-01

    In addition to the statistical bounds discussed, thermal history analysis based on the projected and etchable length distributions of surface intersecting fission tracks is limited by systematic factors related to track revelation, observation and measurement. The effects of track revelation, in particular, distort these distributions in the length intervals of interest. An observation threshold poses a problem if it is described by a critical angle theta sub c , but not if it is described by other criteria proposed in the literature. Measurement imprecisions, predictably, blur the thermal history information contained in these distributions. Measurements of semi-confined tracks, added as a result of surface etching, are a more promising alternative to confined track length measurements for accessing the thermal history record in the fission track length distribution. On the other hand, measurements of the projected lengths of surface intersecting tracks offer the theoretical possibility of determining the tr...

  18. Central Sensitization Inventory as a Predictor of Worse Quality of Life Measures and Increased Length of Stay Following Spinal Fusion.

    Science.gov (United States)

    Bennett, E Emily; Walsh, Kevin M; Thompson, Nicolas R; Krishnaney, Ajit A

    2017-08-01

    Central sensitization is abnormal and intense enhancement of pain mechanism by the central nervous system. Patients with central sensitization may be at higher risk of poor outcomes after spinal fusion. The Central Sensitivity Inventory (CSI) was developed to identify and quantify key symptoms related to central sensitization. In 664 patients who underwent thoracic and/or lumbar fusion, we evaluated retrospectively pretreatment CSI as a predictor of postoperative quality of life measures, length of stay, and discharge status. Preoperative Pain Disability Questionnaire scores, Patient Health Questionnaire-9 scores, and EuroQol-5 Dimensions index scores were significantly worse in patients with preoperative CSI ≥40 compared with patients with preoperative CSI <40 (P < 0.0001 for all). After adjusting for demographic variables, operation duration, and preoperative health status, preoperative CSI was significantly associated with higher postoperative Pain Disability Questionnaire total score (unadjusted P < 0.001, adjusted P = 0.009), higher postoperative Patient Health Questionnaire-9 score (unadjusted P < 0.001, adjusted P = 0.001), and lower postoperative EuroQol-5 Dimensions index (unadjusted P < 0.001, adjusted P = 0.001). For each 10-unit increase in CSI, average length of stay increased by 6.4% (95% confidence interval 0.4%-12.6%, P = 0.035). The odds of being discharged home after adjusting for confounders was not statistically related to preoperative CSI (P = 0.0709). Preoperative CSI was associated with worse quality of life outcomes and increased length of stay after spinal fusions. CSI may be an additional measure in evaluating patients preoperatively to better predict successful spinal fusion outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Distribution of axial length and ocular biometry measured using partial coherence laser interferometry (IOL Master) in an older white population.

    Science.gov (United States)

    Fotedar, Reena; Wang, Jie Jin; Burlutsky, George; Morgan, Ian G; Rose, Kathryn; Wong, Tien Y; Mitchell, Paul

    2010-03-01

    We aimed to describe norms for the distribution of axial length (AL) and other ocular biometric parameters in an older Caucasian population, measured using partial coherence laser interferometry (Zeiss IOL Master; Carl Zeiss AG, Oberkochen, Germany), a technique now routinely used in measuring AL before cataract surgery. We also aimed to assess age and gender relationships with these parameters and their correlations with spherical equivalent refraction (SER). Cross-sectional analysis of the Blue Mountains Eye Study (BMES) cohort at the examinations (10-year follow-up examination). From 2002 to 2004, 1952 persons (76% of surviving baseline BMES participants) aged 59 years or older had ocular biometry measured at the 10-year examinations. Spherical equivalent refraction was calculated as the sum of sphere +0.5 cylinder power, after protocol refraction. Measurements of AL, corneal curvature (K1), anterior chamber depth (ACD), and corneal diameter (WTW) were performed using the IOL Master. Only right phakic eyes (n = 1335) with biometry data were included. Axial length distribution. Mean AL was 23.44 mm (95% confidence interval [CI], 23.38-23.50) and was greater in men, 23.76 mm (CI, 23.68-23.84), than in women, 23.19 mm (CI, 23.11-23.27). The mean K1, ACD, and WTW were 43.42 diopters (D), 3.10 mm, and 12.06 mm, respectively. The AL and ACD distributions were both positively skewed and peaked, whereas the WTW and K1 distributions were near normal. From age 59 years or older, a mean reduction in AL with age was observed (P for trend = 0.005), 0.12 mm per decade (P = 0.0176) in women but only 0.02 mm per decade (P = 0.6319) in men. Mean SER was 0.58 D, and the distribution was peaked with a negative skew. The SER was negatively correlated with both AL (beta coefficient -0.688) and ACD (beta coefficient -0.222), but not with K1 or WTW. These data provide normative values in the older general population for AL measured using the IOL Master. Axial length distribution was

  20. Weight and see: Line bisection in neglect reliably measures the allocation of attention, but not the perception of length.

    Science.gov (United States)

    McIntosh, Robert D; Ietswaart, Magdalena; Milner, A David

    2017-11-01

    Line bisection has long been a routine test for unilateral neglect, along with a range of tests requiring cancellation, copying or drawing. However, several studies have reported that line bisection, as classically administered, correlates relatively poorly with the other tests of neglect, to the extent that some authors have questioned its status as a valid test of neglect. In this article, we re-examine this issue, employing a novel method for administering and analysing line bisection proposed by McIntosh et al. (2005). We report that the measure of attentional bias yielded by this new method (EWB) correlates significantly more highly with cancellation, copying and drawing measures than the classical line bisection error measure in a sample of 50 right-brain damaged patients. Furthermore when EWB was combined with a second measure that emerges from the new analysis (EWS), even higher correlations were obtained. A Principal Components Analysis found that EWB loaded highly on a major factor representing neglect asymmetry, while EWS loaded on a second factor which we propose may measure overall attentional investment. Finally, we found that tests of horizontal length and size perception were related poorly to other measures of neglect in our group. We conclude that this novel approach to interpreting line bisection behaviour provides a promising way forward for understanding the nature of neglect. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Precise NMR measurement and stabilization system of magnetic field of a superconducting 7 T wave length shifter

    CERN Document Server

    Borovikov, V M; Karpov, G V; Korshunov, D A; Kuper, E A; Kuzin, M V; Mamkin, V R; Medvedko, A S; Mezentsev, N A; Repkov, V V; Shkaruba, V A; Shubin, E I; Veremeenko, V F

    2001-01-01

    The system of measurement and stabilization of the magnetic field in the superconducting 7 T wave length shifter (WLS), designed at Budker Institute of Nuclear Physics are described. The measurements are performed by nuclear magnetic resonance (NMR) magnetometer at two points of the WLS magnetic field. Stabilization of the field is provided by the current pumping system. The stabilization system is based on precise NMR measurement of magnetic field as a feedback signal for computer code which control currents inside the superconducting coils. The problem of the magnetic field measurements with NMR method consists in wide spread of field in the measured area (up to 50 Gs/mm), wide temperature range of WLS operating, small space for probe and influence of iron hysteresis. Special solid-state probes were designed to satisfy this requirements. The accuracy of magnetic field measurements at probe locations is not worse than 20 ppm. For the WLS field of 7 T the reproducibility of the magnetic field of 30 ppm has be...

  2. On-line qualification of a micro probing system for precision length measurement of micro-features on precision parts

    International Nuclear Information System (INIS)

    Chen, Yuan-Liu; Ito, So; Kikuchi, Hirotaka; Kobayashi, Ryo; Shimizu, Yuki; Gao, Wei

    2016-01-01

    This paper presents on-line qualification of the effective diameter of the micro-stylus tip ball of a micro probing system for precision length measurement of micro-features on precision parts by utilizing a set of gauge blocks as the qualification artefact, which is composed by one calibrated gauge block and two supporting gauge blocks that are wrung together for a good mechanical stability. The qualification artefact is aligned side by side with the precision part to be measured for enabling a rapid transfer between the qualification step of the probe two-point tip ball diameter and the length measurement step of the precision part. Based on the proposed setup, on-line qualifications of a micro-stylus with a nominal tip ball diameter of 52.6 μ m were carried out by using two methods referred to as Method A and Method B, respectively. Method A is operated by probing the opposite sides of the gap between the two supporting gauge blocks separated by the calibrated gauge block, and Method B is operated by probing the opposite sides of the calibrated gauge block supported by the two supporting gauge blocks. Intensive uncertainty analyses based on the experimental results and the geometrical models were carried out to compare the performances of these two methods. Method A, which was confirmed to be more accurate and faster than Method B, was then employed to measure the width of a micro-gap on a precision part with compensation of the determined effective two-point tip ball diameter. (paper)

  3. On-line qualification of a micro probing system for precision length measurement of micro-features on precision parts

    Science.gov (United States)

    Chen, Yuan-Liu; Ito, So; Kikuchi, Hirotaka; Kobayashi, Ryo; Shimizu, Yuki; Gao, Wei

    2016-07-01

    This paper presents on-line qualification of the effective diameter of the micro-stylus tip ball of a micro probing system for precision length measurement of micro-features on precision parts by utilizing a set of gauge blocks as the qualification artefact, which is composed by one calibrated gauge block and two supporting gauge blocks that are wrung together for a good mechanical stability. The qualification artefact is aligned side by side with the precision part to be measured for enabling a rapid transfer between the qualification step of the probe two-point tip ball diameter and the length measurement step of the precision part. Based on the proposed setup, on-line qualifications of a micro-stylus with a nominal tip ball diameter of 52.6 μm were carried out by using two methods referred to as Method A and Method B, respectively. Method A is operated by probing the opposite sides of the gap between the two supporting gauge blocks separated by the calibrated gauge block, and Method B is operated by probing the opposite sides of the calibrated gauge block supported by the two supporting gauge blocks. Intensive uncertainty analyses based on the experimental results and the geometrical models were carried out to compare the performances of these two methods. Method A, which was confirmed to be more accurate and faster than Method B, was then employed to measure the width of a micro-gap on a precision part with compensation of the determined effective two-point tip ball diameter.

  4. The accuracy of three-dimensional fused deposition modeling (FDM) compared with three-dimensional CT-Scans on the measurement of the mandibular ramus vertical length, gonion-menton length, and gonial angle

    Science.gov (United States)

    Savitri, I. T.; Badri, C.; Sulistyani, L. D.

    2017-08-01

    Presurgical treatment planning plays an important role in the reconstruction and correction of defects in the craniomaxillofacial region. The advance of solid freeform fabrication techniques has significantly improved the process of preparing a biomodel using computer-aided design and data from medical imaging. Many factors are implicated in the accuracy of the 3D model. To determine the accuracy of three-dimensional fused deposition modeling (FDM) models compared with three-dimensional CT scans in the measurement of the mandibular ramus vertical length, gonion-menton length, and gonial angle. Eight 3D models were produced from the CT scan data (DICOM file) of eight patients at the Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Indonesia, Cipto Mangunkusumo Hospital. Three measurements were done three times by two examiners. The measurements of the 3D CT scans were made using OsiriX software, while the measurements of the 3D models were made using a digital caliper and goniometry. The measurement results were then compared. There is no significant difference between the measurements of the mandibular ramus vertical length, gonion-menton length, and gonial angle using 3D CT scans and FDM 3D models. FDM 3D models are considered accurate and are acceptable for clinical applications in dental and craniomaxillofacial surgery.

  5. A Novel Approach to Determine Strides, Ice Contact, and Swing Phases During Ice Hockey Skating Using a Single Accelerometer.

    Science.gov (United States)

    Stetter, Bernd J; Buckeridge, Erica; von Tscharner, Vinzenz; Nigg, Sandro R; Nigg, Benno M

    2016-02-01

    This study presents a new approach for automated identification of ice hockey skating strides and a method to detect ice contact and swing phases of individual strides by quantifying vibrations in 3D acceleration data during the blade-ice interaction. The strides of a 30-m forward sprinting task, performed by 6 ice hockey players, were evaluated using a 3D accelerometer fixed to a hockey skate. Synchronized plantar pressure data were recorded as reference data. To determine the accuracy of the new method on a range of forward stride patterns for temporal skating events, estimated contact times and stride times for a sequence of 5 consecutive strides was validated. Bland-Altman limits of agreement (95%) between accelerometer and plantar pressure derived data were less than 0.019 s. Mean differences between the 2 capture methods were shown to be less than 1 ms for contact and stride time. These results demonstrate the validity of the novel approach to determine strides, ice contact, and swing phases during ice hockey skating. This technology is accurate, simple, effective, and allows for in-field ice hockey testing.

  6. Direct comparison of flow-FISH and qPCR as diagnostic tests for telomere length measurement in humans.

    Directory of Open Access Journals (Sweden)

    Fernanda Gutierrez-Rodrigues

    Full Text Available Telomere length measurement is an essential test for the diagnosis of telomeropathies, which are caused by excessive telomere erosion. Commonly used methods are terminal restriction fragment (TRF analysis by Southern blot, fluorescence in situ hybridization coupled with flow cytometry (flow-FISH, and quantitative PCR (qPCR. Although these methods have been used in the clinic, they have not been comprehensively compared. Here, we directly compared the performance of flow-FISH and qPCR to measure leukocytes' telomere length of healthy individuals and patients evaluated for telomeropathies, using TRF as standard. TRF and flow-FISH showed good agreement and correlation in the analysis of healthy subjects (R(2 = 0.60; p<0.0001 and patients (R(2 = 0.51; p<0.0001. In contrast, the comparison between TRF and qPCR yielded modest correlation for the analysis of samples of healthy individuals (R(2 = 0.35; p<0.0001 and low correlation for patients (R(2 = 0.20; p = 0.001; Bland-Altman analysis showed poor agreement between the two methods for both patients and controls. Quantitative PCR and flow-FISH modestly correlated in the analysis of healthy individuals (R(2 = 0.33; p<0.0001 and did not correlate in the comparison of patients' samples (R(2 = 0.1, p = 0.08. Intra-assay coefficient of variation (CV was similar for flow-FISH (10.8 ± 7.1% and qPCR (9.5 ± 7.4%; p = 0.35, but the inter-assay CV was lower for flow-FISH (9.6 ± 7.6% vs. 16 ± 19.5%; p = 0.02. Bland-Altman analysis indicated that flow-FISH was more precise and reproducible than qPCR. Flow-FISH and qPCR were sensitive (both 100% and specific (93% and 89%, respectively to distinguish very short telomeres. However, qPCR sensitivity (40% and specificity (63% to detect telomeres below the tenth percentile were lower compared to flow-FISH (80% sensitivity and 85% specificity. In the clinical setting, flow-FISH was more accurate, reproducible, sensitive, and specific in the measurement of human

  7. Windowing UWB microwave, mm-wave multi-port S-parameter measurements using open-ended excess electrical length

    Directory of Open Access Journals (Sweden)

    Gholamreza Askari

    2017-05-01

    Full Text Available Multi-port measurements are a big challenge in circuits' verification, especially when the frequency increases. This study presents a new technique for measuring S-parameters of multi-port ultra-wideband (UWB microwave and mm-wave circuits. The concepts are based on direct or indirect applying modulated UWB impulse radio in desired bandwidth to the one port of the modified multi-port circuit and gathering the reflected signal in the same port and the output signal in the second port in time domain, and the other ports are left opened with a special designed added electrical length. Then by applying intelligent windowing in time domain to the gathering data, and using fast Fourier transform, the desired S-parameters are extracted. Validation of this technique is verified by design and fabrication of a three-port UWB Wilkinson power divider in 22–30 GHz. The simulation and measurement results of the reflection and transmission S-parameters by using this new technique are very close to those are extracted with the conventional vector network analysers S-parameters measurements and show the ability and the accuracy of this technique.

  8. Method Specific Calibration Corrects for DNA Extraction Method Effects on Relative Telomere Length Measurements by Quantitative PCR.

    Science.gov (United States)

    Seeker, Luise A; Holland, Rebecca; Underwood, Sarah; Fairlie, Jennifer; Psifidi, Androniki; Ilska, Joanna J; Bagnall, Ainsley; Whitelaw, Bruce; Coffey, Mike; Banos, Georgios; Nussey, Daniel H

    2016-01-01

    Telomere length (TL) is increasingly being used as a biomarker in epidemiological, biomedical and ecological studies. A wide range of DNA extraction techniques have been used in telomere experiments and recent quantitative PCR (qPCR) based studies suggest that the choice of DNA extraction method may influence average relative TL (RTL) measurements. Such extraction method effects may limit the use of historically collected DNA samples extracted with different methods. However, if extraction method effects are systematic an extraction method specific (MS) calibrator might be able to correct for them, because systematic effects would influence the calibrator sample in the same way as all other samples. In the present study we tested whether leukocyte RTL in blood samples from Holstein Friesian cattle and Soay sheep measured by qPCR was influenced by DNA extraction method and whether MS calibration could account for any observed differences. We compared two silica membrane-based DNA extraction kits and a salting out method. All extraction methods were optimized to yield enough high quality DNA for TL measurement. In both species we found that silica membrane-based DNA extraction methods produced shorter RTL measurements than the non-membrane-based method when calibrated against an identical calibrator. However, these differences were not statistically detectable when a MS calibrator was used to calculate RTL. This approach produced RTL measurements that were highly correlated across extraction methods (r > 0.76) and had coefficients of variation lower than 10% across plates of identical samples extracted by different methods. Our results are consistent with previous findings that popular membrane-based DNA extraction methods may lead to shorter RTL measurements than non-membrane-based methods. However, we also demonstrate that these differences can be accounted for by using an extraction method-specific calibrator, offering researchers a simple means of accounting for

  9. Measuring the length distribution of self-assembled lipid nanotubes by orientation control with a high-frequency alternating current electric field in aqueous solutions.

    Science.gov (United States)

    Hirano, Ken; Aoyagi, Masaru; Ishido, Tomomi; Ooie, Toshihiko; Frusawa, Hiroshi; Asakawa, Masumi; Shimizu, Toshimi; Ishikawa, Mitsuru

    2009-02-15

    The present work addresses the length distribution of self-assembled lipid nanotubes (LNTs) by controlling the orientation of the LNTs using an alternating current (ac) electric field in aqueous solutions. The effect of the ac field on the orientation and rotation of individual LNTs was examined to evaluate the optimum orientation frequency by visualizing the individual LNTs in real time. By using the high-frequency ac field, we have successfully measured the length distribution for two different types of LNTs and have quantitatively analyzed the maximum occurrences of the length distribution as well as the extension of the longer length region.

  10. Reliability of the two-point measurement of the spatial correlation length from Gaussian-shaped fluctuating signals in fusion-grade plasmas

    Science.gov (United States)

    Kim, Jaewook; Nam, Y. U.; Lampert, M.; Ghim, Y.-C.

    2016-10-01

    A statistical method for the estimation of the spatial correlation lengths of Gaussian-shaped fluctuating signals with two measurement points is examined to quantitatively evaluate its reliability (variance) and accuracy (bias error). The standard deviation of the correlation value is analytically derived for randomly distributed Gaussian shaped fluctuations satisfying stationarity and homogeneity, allowing us to evaluate, as a function of fluctuation-to-noise ratios, the sizes of averaging time windows and the ratios of the distance between the two measurement points to the true correlation length, and the goodness of the two-point measurement for estimating the spatial correlation length. Analytic results are confirmed with numerically generated synthetic data and real experimental data obtained with the KSTAR beam emission spectroscopy diagnostic. Our results can be applied to Gaussian-shaped fluctuating signals where a correlation length must be measured with only two measurement points.

  11. Estimating age from recapture data: integrating incremental growth measures with ancillary data to infer age-at-length

    Science.gov (United States)

    Eaton, Mitchell J.; Link, William A.

    2011-01-01

    Estimating the age of individuals in wild populations can be of fundamental importance for answering ecological questions, modeling population demographics, and managing exploited or threatened species. Significant effort has been devoted to determining age through the use of growth annuli, secondary physical characteristics related to age, and growth models. Many species, however, either do not exhibit physical characteristics useful for independent age validation or are too rare to justify sacrificing a large number of individuals to establish the relationship between size and age. Length-at-age models are well represented in the fisheries and other wildlife management literature. Many of these models overlook variation in growth rates of individuals and consider growth parameters as population parameters. More recent models have taken advantage of hierarchical structuring of parameters and Bayesian inference methods to allow for variation among individuals as functions of environmental covariates or individual-specific random effects. Here, we describe hierarchical models in which growth curves vary as individual-specific stochastic processes, and we show how these models can be fit using capture–recapture data for animals of unknown age along with data for animals of known age. We combine these independent data sources in a Bayesian analysis, distinguishing natural variation (among and within individuals) from measurement error. We illustrate using data for African dwarf crocodiles, comparing von Bertalanffy and logistic growth models. The analysis provides the means of predicting crocodile age, given a single measurement of head length. The von Bertalanffy was much better supported than the logistic growth model and predicted that dwarf crocodiles grow from 19.4 cm total length at birth to 32.9 cm in the first year and 45.3 cm by the end of their second year. Based on the minimum size of females observed with hatchlings, reproductive maturity was estimated

  12. Measurement of the mass of the top quark using the transverse decay length and lepton transverse momentum techniques

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Christian

    2014-05-02

    A measurement of the mass of the top quark using the transverse momentum of the lepton and decay length of the B-Hadron has been presented. The result is m{sub Top}=(170.4±1.1{sub stat.}±2.3{sub syst.}) GeV. This is compatible with previous measurements of the mass of the top quark, done by either the ATLAS collaboration or other experiments. The total uncertainty on the result of this analysis, Δ{sup total}m{sub Top}=2.6 GeV is larger than results by other measurements. However, with an jet energy scale uncertainty of only Δ{sup Jes}m{sub Top}=0.3 GeV it has one of the smallest uncertainties caused by this source. In a combination of results this will help reducing the total uncertainty on the mass of the top quark. The value of 0.42 on the strength on final state radiation indicates that the simulation underestimates the strength of final state radiation. There is currently work ongoing aiming to publish the results found in this thesis in the context of an official ATLAS publication. Additionally the uncertainties can be compared with those one would obtain by using only one of the two variables. If one considers only the transverse decay length, a statistical error of Δm{sub Top}{sup stat.}=1.7 GeV and a systematic uncertainty of Δm{sub Top}{sup stat.}=7.8 GeV is obtained, dominated by the uncertainty on initial and final state radiation. The statistical uncertainty obtained by using the transverse momentum of the lepton is with Δm{sub Top}{sup stat.}=1.4 GeV a bit lower than the one obtained by the transverse decay length alone but still larger than the one of the presented measurement. The systematic uncertainty obtained is Δm{sub Top}{sup stat.}=2.7 GeV. Combining the two variables is therefore worthwhile compared with using only the transverse momentum of the lepton alone. The dominant uncertainties on the measurement are caused by imperfect knowledge of the simulation parameters, especially the choice of Monte-Carlo generator. Other large

  13. Correlation of Leukocyte Telomere Length Measurement Methods in Patients with Dyskeratosis Congenita and in Their Unaffected Relatives.

    Science.gov (United States)

    Khincha, Payal P; Dagnall, Casey L; Hicks, Belynda; Jones, Kristine; Aviv, Abraham; Kimura, Masayuki; Katki, Hormuzd; Aubert, Geraldine; Giri, Neelam; Alter, Blanche P; Savage, Sharon A; Gadalla, Shahinaz M

    2017-08-13

    Several methods have been employed to measure telomere length (TL) in human studies. It has been difficult to directly compare the results from these studies because of differences in the laboratory techniques and output parameters. We compared TL measurements (TLMs) by the three most commonly used methods, quantitative polymerase chain reaction (qPCR), flow cytometry with fluorescence in situ hybridization (flow FISH) and Southern blot, in a cohort of patients with the telomere biology disorder dyskeratosis congenita (DC) and in their unaffected relatives (controls). We observed a strong correlation between the Southern blot average TL and the flow FISH total lymphocyte TL in both the DC patients and their unaffected relatives ( R ² of 0.68 and 0.73, respectively). The correlation between the qPCR average TL and that of the Southern blot method was modest ( R ² of 0.54 in DC patients and of 0.43 in unaffected relatives). Similar results were noted when comparing the qPCR average TL and the flow FISH total lymphocyte TL ( R ² of 0.49 in DC patients and of 0.42 in unaffected relatives). In conclusion, the strengths of the correlations between the three widely used TL assays (qPCR, flow FISH, and Southern blot) were significantly different. Careful consideration is warranted when selecting the method of TL measurement for research and for clinical studies.

  14. Correlation of Leukocyte Telomere Length Measurement Methods in Patients with Dyskeratosis Congenita and in Their Unaffected Relatives

    Science.gov (United States)

    Khincha, Payal P.; Hicks, Belynda; Jones, Kristine; Aviv, Abraham; Kimura, Masayuki; Katki, Hormuzd; Aubert, Geraldine; Giri, Neelam; Alter, Blanche P.; Savage, Sharon A.; Gadalla, Shahinaz M.

    2017-01-01

    Several methods have been employed to measure telomere length (TL) in human studies. It has been difficult to directly compare the results from these studies because of differences in the laboratory techniques and output parameters. We compared TL measurements (TLMs) by the three most commonly used methods, quantitative polymerase chain reaction (qPCR), flow cytometry with fluorescence in situ hybridization (flow FISH) and Southern blot, in a cohort of patients with the telomere biology disorder dyskeratosis congenita (DC) and in their unaffected relatives (controls). We observed a strong correlation between the Southern blot average TL and the flow FISH total lymphocyte TL in both the DC patients and their unaffected relatives (R2 of 0.68 and 0.73, respectively). The correlation between the qPCR average TL and that of the Southern blot method was modest (R2 of 0.54 in DC patients and of 0.43 in unaffected relatives). Similar results were noted when comparing the qPCR average TL and the flow FISH total lymphocyte TL (R2 of 0.49 in DC patients and of 0.42 in unaffected relatives). In conclusion, the strengths of the correlations between the three widely used TL assays (qPCR, flow FISH, and Southern blot) were significantly different. Careful consideration is warranted when selecting the method of TL measurement for research and for clinical studies. PMID:28805708

  15. Optical Design of a Broadband Infrared Spectrometer for Bunch Length Measurement at the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Kiel; /SLAC

    2012-09-07

    The electron pulses generated by the Linac Coherent Light Source at the SLAC National Accelerator Laboratory occur on the order of tens of femtoseconds and cannot be directly measured by conventional means. The length of the pulses can instead be reconstructed by measuring the spectrum of optical transition radiation emitted by the electrons as they move toward a conducting foil. Because the emitted radiation occurs in the mid-infrared from 0.6 to 30 microns a novel optical layout is required. Using a helium-neon laser with wavelength 633 nm, a series of gold-coated off-axis parabolic mirrors were positioned to direct a beam through a zinc selenide prism and to a focus at a CCD camera for imaging. Constructing this layout revealed a number of novel techniques for reducing the aberrations introduced into the system by the off-axis parabolic mirrors. The beam had a recorded radius of less than a millimeter at its final focus on the CCD imager. This preliminary setup serves as a model for the spectrometer that will ultimately measure the LCLS electron pulse duration.

  16. Making Strides

    Science.gov (United States)

    Jarrell, Andrea

    2013-01-01

    In the mad dash to complete the plethora of projects that lead up to the public launch of a campaign, it would be easy to start thinking of the kickoff as a goal in itself, but it's merely a mile marker in the marathon of a fundraising campaign that may last five to 10 years. Given that only a fraction of an institution's constituents may attend a…

  17. The effect of gestational age and cervical length measurements in the prediction of spontaneous preterm birth in twin pregnancies : an individual patient level meta-analysis

    NARCIS (Netherlands)

    Kindinger, L M; Poon, L C; Cacciatore, S; MacIntyre, D A; Fox, N S; Schuit, E; Mol, B W; Liem, S; Lim, A C; Serra, V; Perales, A; Hermans, F; Darzi, A; Bennett, P; Nicolaides, K H; Teoh, T G

    2016-01-01

    OBJECTIVE: To assess the effect of gestational age (GA) and cervical length (CL) measurements at transvaginal ultrasound (TVUS) in the prediction of preterm birth in twin pregnancy. DESIGN: Individual patient data (IPD) meta-analysis. SETTING: International multicentre study. POPULATION:

  18. Variations of OCT measurements corrected for the magnification effect according to axial length and refractive error in children

    Directory of Open Access Journals (Sweden)

    Inmaculada Bueno-Gimeno

    2018-01-01

    Full Text Available Purpose: The aim of this paper was to examine the distribution of macular, retinal nerve fiber layer (RNFL thickness and optic disc parameters of myopic and hyperopic eyes in comparison with emmetropic control eyes and to investigate their variation according to axial length (AL and spherical equivalent (SE in healthy children. Methods: This study included 293 pairs of eyes of 293 children (145 boys and 148 girls, ranging in age from 6 to 17 years. Subjects were divided according to SE in control (emmetropia, 99 children, myopia (100 children and hyperopia (94 children groups and according to axial AL in 68 short (25.00mm, 36. Macular parameters, RNFL thickness and optic disc morphology were assessed by the CirrusTM HD-OCT. AL was measured using the IOL-Master system. Littmann’s formula was used for calculating the corrected AL-related ocular magnification. Results: Mean age (±SD was 10.84±3.05 years; mean (±SD SE was +0.14±0.51 D (range from −8.75 to +8.25 D and mean AL (±SD was 23.12±1.49. Average RNFL thickness, average macular thickness and macular volume decreased as AL and myopia increased. No correlations between AL/SE and optic disc parameters were found after correcting for magnification effect. Conclusions: AL and refractive error affect measurements of macular and RNFL thickness in healthy children. To make a correct interpretation of OCT measurements, ocular magnification effect should be taken into account by clinicians or OCT manufacturers.

  19. Inter-laboratory validation of the measurement of follicle stimulating hormone (FSH after various lengths of frozen storage

    Directory of Open Access Journals (Sweden)

    Behr Barry

    2010-11-01

    Full Text Available Abstract Background Serum follicle stimulating hormone (FSH levels are used clinically to evaluate infertility, pituitary and gonadal disorders. With increased frequency of research collaborations across institutions, it is essential that inter-laboratory validation is addressed. Methods An inter-laboratory validation of three commercial FSH immunoassays was performed with human serum samples of varying frozen storage length (2 batches of 15 samples each at -25 degree C. Percentage differences and Bland-Altman limits of agreement were calculated. Results The inter- and intra-laboratory consistency of FSH values with the same assay manufacturer was much higher after shorter-term storage (frozen for less than 11 months, mean percentage degradation less than 4% than after long-term storage (2-3 years, mean percentage degradation = 23%. Comparing assay results from different manufacturers, there was similar overall long term degradation as seen with the same manufacturer (-25%, however the degradation was greater when the original FSH was greater than 20 mIU/mL relative to less than 10 mIU/mL (p Conclusion The findings suggest that degradation of serum samples stored between 11 months and 2-3 years at -25 degrees C can lead to unstable FSH measurements. Inter-laboratory variability due to frozen storage time and manufacturer differences in assay results should be accounted for when designing and implementing research or clinical quality control activities involving serum FSH at multiple study sites.

  20. Comparison of left and right ventricular volume measurement using the Simpson's method and the area length method

    International Nuclear Information System (INIS)

    Hergan, Klaus; Schuster, Antonius; Fruehwald, Julia; Mair, Michael; Burger, Ralph; Toepker, Michael

    2008-01-01

    Purpose: To compare ventricular volume measurement using a volumetric approach in the three standard cardiac planes and ventricular volume estimation by a geometrical model, the Area-Length method (ALM). Materials and methods: Fifty-six healthy volunteers were examined (27 males, 29 females) on a 1.5 T MR-unit with ECG-triggered steady state free precision (SSFP) Cine-MR sequences and parallel image acquisition. Multiple slices in standardized planes including the short-axis view (sa), 4-chamber view (4ch), left and right 2-chamber views (2ch) were used to cover the whole heart. End-systolic and end-diastolic ventricular volumes (EDV, ESV), stroke volume (SV), and ejection fraction (EF) were calculated with Simpson's rule in all planes and with ALM in the 2ch and 4ch planes. Global function parameters measured in the sa plane were compared with those obtained in the other imaging planes. Results: A very good correlation is observed when comparing functional parameters calculated with Simpson's rule in all imaging planes: for instance, the mean EDV/ESV of the left and right ventricle of the female population group measured in sa, 4ch, and 2ch: left ventricle EDV/ESV 114.3/44.4, 120.9/46.5, and 117.7/45.3 ml; right ventricle EDV/ESV 106.6/46.0, 101.2/41.1, and 103.5/43.0 ml. Functional parameters of the left ventricle calculated with ALM in 2ch and 4ch correlate to parameters obtained in sa with Simpson's rule in the range of 5-10%: for instance, the EDV/ESV of the left ventricle of the male population group measured in the sa, 4ch, and 2ch: 160.3/63.5, 163.1/59.0, and 167.0/65.7 ml. Functional parameters of the right ventricle measured with ALM in 4ch are 40-50% lower and calculated in 2ch almost double as high as compared with the parameters obtained in sa with Simpson's rule: for instance, male right ventricular EDV/ESV measured in sa, 4ch, and 2ch: 153.4/68.1, 97.5/34.5, and 280.2/123.2 ml. The EF correlates for all imaging planes measured with the Simpson's rule

  1. Comparison of left and right ventricular volume measurement using the Simpson's method and the area length method

    Energy Technology Data Exchange (ETDEWEB)

    Hergan, Klaus [Department of Radiology, Paracelsus Medical University Salzburg (Austria)], E-mail: k.hergan@salk.at; Schuster, Antonius [Department of Radiology, LKH Feldkirch (Austria); Fruehwald, Julia [Department of Radiology, Medical University Vienna (Austria); Mair, Michael; Burger, Ralph; Toepker, Michael [Department of Radiology, LKH Feldkirch (Austria)

    2008-02-15

    Purpose: To compare ventricular volume measurement using a volumetric approach in the three standard cardiac planes and ventricular volume estimation by a geometrical model, the Area-Length method (ALM). Materials and methods: Fifty-six healthy volunteers were examined (27 males, 29 females) on a 1.5 T MR-unit with ECG-triggered steady state free precision (SSFP) Cine-MR sequences and parallel image acquisition. Multiple slices in standardized planes including the short-axis view (sa), 4-chamber view (4ch), left and right 2-chamber views (2ch) were used to cover the whole heart. End-systolic and end-diastolic ventricular volumes (EDV, ESV), stroke volume (SV), and ejection fraction (EF) were calculated with Simpson's rule in all planes and with ALM in the 2ch and 4ch planes. Global function parameters measured in the sa plane were compared with those obtained in the other imaging planes. Results: A very good correlation is observed when comparing functional parameters calculated with Simpson's rule in all imaging planes: for instance, the mean EDV/ESV of the left and right ventricle of the female population group measured in sa, 4ch, and 2ch: left ventricle EDV/ESV 114.3/44.4, 120.9/46.5, and 117.7/45.3 ml; right ventricle EDV/ESV 106.6/46.0, 101.2/41.1, and 103.5/43.0 ml. Functional parameters of the left ventricle calculated with ALM in 2ch and 4ch correlate to parameters obtained in sa with Simpson's rule in the range of 5-10%: for instance, the EDV/ESV of the left ventricle of the male population group measured in the sa, 4ch, and 2ch: 160.3/63.5, 163.1/59.0, and 167.0/65.7 ml. Functional parameters of the right ventricle measured with ALM in 4ch are 40-50% lower and calculated in 2ch almost double as high as compared with the parameters obtained in sa with Simpson's rule: for instance, male right ventricular EDV/ESV measured in sa, 4ch, and 2ch: 153.4/68.1, 97.5/34.5, and 280.2/123.2 ml. The EF correlates for all imaging planes measured

  2. ePAT: A simple method to tag adenylated RNA to measure poly(A)-tail length and other 3′ RACE applications

    OpenAIRE

    Jänicke, Amrei; Vancuylenberg, John; Boag, Peter R.; Traven, Ana; Beilharz, Traude H.

    2012-01-01

    The length of the poly(A)-tail that terminates most mRNA can serve as a readout of its metabolism. A long poly(A)-tail is generally associated with actively translating mRNA, whereas a short poly(A)-tail often indicates a translationally repressed state. Here, the authors present a simple new method to measure transcript-specific poly(A)-tail length using standard molecular biology reagents.

  3. Research staff training in a multisite randomized clinical trial: Methods and recommendations from the Stimulant Reduction Intervention using Dosed Exercise (STRIDE) trial.

    Science.gov (United States)

    Walker, Robrina; Morris, David W; Greer, Tracy L; Trivedi, Madhukar H

    2014-01-01

    Descriptions of and recommendations for meeting the challenges of training research staff for multisite studies are limited despite the recognized importance of training on trial outcomes. The STRIDE (STimulant Reduction Intervention using Dosed Exercise) study is a multisite randomized clinical trial that was conducted at nine addiction treatment programs across the United States within the National Drug Abuse Treatment Clinical Trials Network (CTN) and evaluated the addition of exercise to addiction treatment as usual (TAU), compared to health education added to TAU, for individuals with stimulant abuse or dependence. Research staff administered a variety of measures that required a range of interviewing, technical, and clinical skills. In order to address the absence of information on how research staff are trained for multisite clinical studies, the current manuscript describes the conceptual process of training and certifying research assistants for STRIDE. Training was conducted using a three-stage process to allow staff sufficient time for distributive learning, practice, and calibration leading up to implementation of this complex study. Training was successfully implemented with staff across nine sites. Staff demonstrated evidence of study and procedural knowledge via quizzes and skill demonstration on six measures requiring certification. Overall, while the majority of staff had little to no experience in the six measures, all research assistants demonstrated ability to correctly and reliably administer the measures throughout the study. Practical recommendations are provided for training research staff and are particularly applicable to the challenges encountered with large, multisite trials.

  4. Assessment of hamstring muscle length in school-aged children using the sit-and-reach test and the inclinometer measure of hip joint angle.

    Science.gov (United States)

    Cornbleet, S L; Woolsey, N B

    1996-08-01

    The sit-and-reach test (SRT) is commonly used to assess flexibility of the spine and length of the hamstring muscles. The purposes of this study were (1) to describe hamstring muscle length as reflected by use of the SRT and the hip joint angle (HJA) in children, (2) to examine the correlation between SRT and HJA measurements, and (3) to examine gender differences for both measures. The participants were 410 school-aged children (211 girls, 199 boys). Each child performed the SRT. In the final position, the SRT score was obtained and the HJA was measured using an inclinometer placed over the sacrum. A mean SRT value of 24 cm and a mean HJA value of 81 degrees were obtained for all subjects. There was a strong correlation between the SRT and HJA measurements (r = .76). There was a difference between boys and girls for both measures. The results suggest differences in expectations for hamstring muscle length in boys and girls. Although scores for the SRT and HJA were correlated, we prefer to assess hamstring muscle length using HJA scores because these scores are not influenced by anthropometric factors or spinal mobility. The results of this study suggest that HJA measurements guide treatment more effectively than do SRT measurements.

  5. Determination of the length and position of the lower oesophageal sphincter (LOS) by correlation of external measurements with combined radiographic and manometric estimations in the cat

    International Nuclear Information System (INIS)

    Hashim, M.A.; Waterman, A.E.

    1992-01-01

    Fifty DSH cats were studied radiographically and a highly significant linear correlation was found between the length of the oesophagus measured to the diaphragmatic line on the radiographs and the externally measured distance from the lower jaw incisor teeth to the anterior border of the head of 10th rib. A subsequent manometric study utilizing this correlation in 40 cats suggests that the functional lower oesophageal sphincter (LOS) is situated almost at the level of the diaphragm in the cat. Significant differences were found between the length of the LOS in cats anaesthetized with ketamine compared to alphaxalone-alphadolone or xylazine-ketamine-atropine. The mean lengths of the LOS was 1.42 +/- 0.3 cm. The findings of this study indicate that external measurements can be used to position catheters for accurate oesophageal manometry in the cat

  6. Fundamental length and relativistic length

    International Nuclear Information System (INIS)

    Strel'tsov, V.N.

    1988-01-01

    It si noted that the introduction of fundamental length contradicts the conventional representations concerning the contraction of the longitudinal size of fast-moving objects. The use of the concept of relativistic length and the following ''elongation formula'' permits one to solve this problem

  7. Flame Length

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — Flame length was modeled using FlamMap, an interagency fire behavior mapping and analysis program that computes potential fire behavior characteristics. The tool...

  8. Together We STRIDE: A quasi-experimental trial testing the effectiveness of a multi-level obesity intervention for Hispanic children in rural communities.

    Science.gov (United States)

    Ko, Linda K; Rillamas-Sun, Eileen; Bishop, Sonia; Cisneros, Oralia; Holte, Sarah; Thompson, Beti

    2018-04-01

    Hispanic children are disproportionally overweight and obese compared to their non-Hispanic white counterparts in the US. Community-wide, multi-level interventions have been successful to promote healthier nutrition, increased physical activity (PA), and weight loss. Using community-based participatory approach (CBPR) that engages community members in rural Hispanic communities is a promising way to promote behavior change, and ultimately weight loss among Hispanic children. Led by a community-academic partnership, the Together We STRIDE (Strategizing Together Relevant Interventions for Diet and Exercise) aims to test the effectiveness of a community-wide, multi-level intervention to promote healthier diets, increased PA, and weight loss among Hispanic children. The Together We STRIDE is a parallel quasi-experimental trial with a goal of recruiting 900 children aged 8-12 years nested within two communities (one intervention and one comparison). Children will be recruited from their respective elementary schools. Components of the 2-year multi-level intervention include comic books (individual-level), multi-generational nutrition and PA classes (family-level), teacher-led PA breaks and media literacy education (school-level), family nights, a farmer's market and a community PA event (known as ciclovia) at the community-level. Children from the comparison community will receive two newsletters. Height and weight measures will be collected from children in both communities at three time points (baseline, 6-months, and 18-months). The Together We STRIDE study aims to promote healthier diet and increased PA to produce healthy weight among Hispanic children. The use of CBPR approach and the engagement of the community will springboard strategies for intervention' sustainability. Clinical Trials Registration Number: NCT02982759 Retrospectively registered. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Accessible length scale of the in-plane structure in polarized neutron off-specular and grazing-incidence small-angle scattering measurements

    Science.gov (United States)

    Maruyama, R.; Bigault, T.; Wildes, A. R.; Dewhurst, C. D.; Saerbeck, T.; Honecker, D.; Yamazaki, D.; Soyama, K.; Courtois, P.

    2017-06-01

    Polarized neutron off-specular and grazing-incidence small-angle scattering measurements are useful methods to investigate the in-plane structure and its correlation of layered systems. Although these measurements give information on complementary and overlapping length scale, the different characteristics between them need to be taken into account when performed. In this study, the difference in the accessible length scale of the in-plane structure, which is one of the most important characteristics, was discussed using an Fe/Si multilayer together with simulations based on the distorted wave Born approximation.

  10. Feasibility of repeated self-measurements of maximum step length and gait speed by community-dwelling older persons

    NARCIS (Netherlands)

    Bongers, K.T.; Schoon, Y.; Olde Rikkert, M.G.M.

    2016-01-01

    OBJECTIVES: Self-management of mobility and fall risk can be important in fall prevention; however, it remains unstudied. Therefore, the current study assessed whether community-dwelling older persons were able to repeatedly self-assess maximum step length (MSL) and gait speed (GS) in their own home

  11. Measurements on the influence of the length of the daily submergence time on the condition and appearence of mussels (

    NARCIS (Netherlands)

    Basal, M.

    1972-01-01

    Mussels (Mytilus edulis) living at different intertidal levels (viz. about 40, 10 and 0% of time exposed to the air) were compared as to length distribution, meat and shell weight, and linear dimensions. The long-exposed mussels were found to be on average smaller, to contain less meat, to

  12. Development and Psychometric Evaluation of a New Instrument for Measuring Sleep Length and Television and Computer Habits of Swedish School-Age Children

    Science.gov (United States)

    Garmy, Pernilla; Jakobsson, Ulf; Nyberg, Per

    2012-01-01

    The aim was to develop a new instrument for measuring length of sleep as well as television and computer habits in school-age children. A questionnaire was constructed for use when children visit the school health care unit. Three aspects of the validity of the questionnaire were examined: its face validity, content validity, and construct…

  13. Instrumented gait analysis: a measure of gait improvement by a wheeled walker in hospitalized geriatric patients.

    Science.gov (United States)

    Schülein, Samuel; Barth, Jens; Rampp, Alexander; Rupprecht, Roland; Eskofier, Björn M; Winkler, Jürgen; Gaßmann, Karl-Günter; Klucken, Jochen

    2017-02-27

    In an increasing aging society, reduced mobility is one of the most important factors limiting activities of daily living and overall quality of life. The ability to walk independently contributes to the mobility, but is increasingly restricted by numerous diseases that impair gait and balance. The aim of this cross-sectional observation study was to examine whether spatio-temporal gait parameters derived from mobile instrumented gait analysis can be used to measure the gait stabilizing effects of a wheeled walker (WW) and whether these gait parameters may serve as surrogate marker in hospitalized patients with multifactorial gait and balance impairment. One hundred six patients (ages 68-95) wearing inertial sensor equipped shoes passed an instrumented walkway with and without gait support from a WW. The walkway assessed the risk of falling associated gait parameters velocity, swing time, stride length, stride time- and double support time variability. Inertial sensor-equipped shoes measured heel strike and toe off angles, and foot clearance. The use of a WW improved the risk of spatio-temporal parameters velocity, swing time, stride length and the sagittal plane associated parameters heel strike and toe off angles in all patients. First-time users (FTUs) showed similar gait parameter improvement patterns as frequent WW users (FUs). However, FUs with higher levels of gait impairment improved more in velocity, stride length and toe off angle compared to the FTUs. The impact of a WW can be quantified objectively by instrumented gait assessment. Thus, objective gait parameters may serve as surrogate markers for the use of walking aids in patients with gait and balance impairments.

  14. Development and reliability of the Achilles Tendon Length Measure and comparison with the Achilles Tendon Resting Angle on patients with an Achilles tendon rupture

    DEFF Research Database (Denmark)

    Hansen, Maria Swennergren; Barfod, Kristoffer Weisskirchner; Kristensen, Morten Tange

    2017-01-01

    BACKGROUND: There is a need for a valid, reliable, and easily applicable clinical measure of the length of the Achilles tendon (AT) after rupture. This study examines the reliability of a new ruler based measurement, the Achilles Tendon Length Measure (ATLM) in comparison with the goniometer......-based Achilles Tendon Resting Angle (ATRA). METHODS: Measurements were performed by two independent physiotherapists eight weeks after AT rupture on 28 patients treated non-operatively. RESULTS: The mean (SD) injured ATLM was 56.5 (2.3)cm, ICC2.1 0.91(CI [0.72-0.97]), SEM 0.7cm (SEM% 1.2), MDC 1.9cm (MDC% 3...

  15. Upright MRI measurement of mechanical axis and frontal plane alignment as a new technique: a comparative study with weight bearing full length radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Liodakis, Emmanouil; Kenawey, Mohamed; Doxastaki, Iosifina; Krettek, Christian; Haasper, Carl; Hankemeier, Stefan [Medical School Hannover, Department of Trauma Surgery, Hannover (Germany)

    2011-07-15

    The purpose of this prospective study was to investigate the practicality, accuracy, and reliability of upright MR imaging as a new radiation-free technique for the measurement of mechanical axis. We used upright MRI in 15 consecutive patients (30 limbs, 44.7 {+-} 20.6 years old) to measure mechanical axis deviation (MAD), hip-knee-ankle (HKA) angle, leg length, and all remaining angles of the frontal plane alignment according to Paley (mLPFA, mLDTA, mMPTA, mLDTA, JLCA). The measurements were compared to weight bearing full length radiographs, which are considered to be the standard of reference for planning corrective surgery. FDA-approved medical planning software (MediCAD) was used for the above measurements. Intra- and inter-observer reproducibility using mean absolute differences was also calculated for both methods. The correlation coefficient between angles determined with upright MRI and weight bearing full length radiographs was high for mLPFA, mLDTA, mMPTA, mLDTA, and the HKA angle (r > 0.70). Mean interobserver and intraobserver agreements for upright MRI were also very high (r > 0.89). The leg length and the MAD were significantly underestimated by MRI (-3.2 {+-} 2.2 cm, p < 0.001 and -6.2 {+-} 4.4 mm, p = 0.006, respectively). With the exception of underestimation of leg length and MAD, upright MR imaging measurements of the frontal plane angles are precise and produce reliable, reproducible results. (orig.)

  16. Fundamental length

    International Nuclear Information System (INIS)

    Pradhan, T.

    1975-01-01

    The concept of fundamental length was first put forward by Heisenberg from purely dimensional reasons. From a study of the observed masses of the elementary particles known at that time, it is sumrised that this length should be of the order of magnitude 1 approximately 10 -13 cm. It was Heisenberg's belief that introduction of such a fundamental length would eliminate the divergence difficulties from relativistic quantum field theory by cutting off the high energy regions of the 'proper fields'. Since the divergence difficulties arise primarily due to infinite number of degrees of freedom, one simple remedy would be the introduction of a principle that limits these degrees of freedom by removing the effectiveness of the waves with a frequency exceeding a certain limit without destroying the relativistic invariance of the theory. The principle can be stated as follows: It is in principle impossible to invent an experiment of any kind that will permit a distintion between the positions of two particles at rest, the distance between which is below a certain limit. A more elegant way of introducing fundamental length into quantum theory is through commutation relations between two position operators. In quantum field theory such as quantum electrodynamics, it can be introduced through the commutation relation between two interpolating photon fields (vector potentials). (K.B.)

  17. Body mass index, Bishop score, and sonographic measurement of the cervical length as predictors of successful labor induction in twin gestations.

    Science.gov (United States)

    Park, Kyo-Hoon; Hong, Joon-Seok; Kang, Woong-Sun; Shin, Dong-Myung; Kim, Shi-Nae

    2009-01-01

    To evaluate the predictive value of body mass index (BMI), Bishop score, and sonographic measurement of cervical length for predicting successful labor induction (defined as an ability to achieve the active phase of labor corresponding to a cervical dilatation of > or =4 cm within 12 h of initiating oxytocin) in near-term twin gestations. This prospective, observational study enrolled 72 consecutive women with twin gestations at >36.0 weeks' gestation who were scheduled for induction of labor. Transvaginal ultrasound for measurement of the cervical length was performed and the Bishop score was determined by digital examination. The BMI was calculated based on the weight and height at the time of induction. Labor induction was successful in 63% (45/72) of women. The mean BMI was significantly lower in women who had successfully induced labor, but no significant differences existed with respect to the mean cervical length, median Bishop score, proportion of parous and nulliparous women, and the mean total birth weight of the twin pairs between the two patient groups. Multiple logistic regression demonstrated that only BMI provided a significant contribution in predicting successful labor induction. BMI independently predicted the success of labor induction in twin gestations but the sonographic measurement of the cervical length and Bishop score had poor predictive values for successful induction.

  18. Effect of treadmill versus overground running on the structure of variability of stride timing.

    Science.gov (United States)

    Lindsay, Timothy R; Noakes, Timothy D; McGregor, Stephen J

    2014-04-01

    Gait timing dynamics of treadmill and overground running were compared. Nine trained runners ran treadmill and track trials at 80, 100, and 120% of preferred pace for 8 min. each. Stride time series were generated for each trial. To each series, detrended fluctuation analysis (DFA), power spectral density (PSD), and multiscale entropy (MSE) analysis were applied to infer the regime of control along the randomness-regularity axis. Compared to overground running, treadmill running exhibited a higher DFA and PSD scaling exponent, as well as lower entropy at non-preferred speeds. This indicates a more ordered control for treadmill running, especially at non-preferred speeds. The results suggest that the treadmill itself brings about greater constraints and requires increased voluntary control. Thus, the quantification of treadmill running gait dynamics does not necessarily reflect movement in overground settings.

  19. Effects of different storage and measuring methods on larval length values for the blow flies (Diptera: Calliphoridae) Lucilia sericata and Calliphora vicina.

    Science.gov (United States)

    Bugelli, Valentina; Campobasso, Carlo Pietro; Verhoff, Marcel A; Amendt, Jens

    2017-05-01

    In forensic entomology, the methods of sampling, killing, and storing entomological samples can affect larval age estimation, and, hence, the estimation of the minimum post-mortem interval. In the existing manuals, there is a certain amount of heterogeneity regarding methods and the recommendations for best practice in forensic entomology are insufficiently validated. This study evaluated three different length-measurement methods for larval stages and examined the influence of different killing and storing methods on the larval length of two forensically important blow flies, Lucilia sericata and Calliphora vicina. The three different measuring methods were a) a ruler with a 0.1mm scale, b) a geometrical micrometer, and c) a computer-aided stereomicroscope. They were used to measure the length of L 1 -L 3 C. vicina larvae and detect no significant differences. This supports the view that a simple tool like a geometrical micrometer can produce reliable results in forensic entomology. Newly hatched larvae of L. sericata and C. vicina were killed with hot water (HW) and divided into two equal subsamples. Lengths of all larvae were measured immediately after killing, then every 24h until day 4, and once more after 7days of storage in ≥70%-ethanol. L. sericata larvae only showed significant changes in length in the HW group stored at room temperature. After 4 and 7days of storage, these 24-h- and 72-h-old larvae showed a significant decrease in length compared with those in a fridge at 6°C. This decrease can, however, be considered a negligible natural variation without forensically relevant consequences for larval age estimation of L. sericata samples. For C. vicina, an increase in length was observed over time. This was significant only for younger larvae (24-48h old) stored in 70%-ethanol. This variance in length can lead to a wrong estimation of age; however, only for larvae stored in 70%-ethanol, not for those stored in 96%-ethanol. We examined the influence of

  20. First observation of $\\pi^{-}K^+$ and $\\pi^{+}K^-$ atoms, their lifetime measurement and $\\pi K$ scattering lengths evaluation

    CERN Document Server

    Afanasyev, Leonid

    2016-01-01

    The Low Energy QCD allows to calculate the ππ and π K scattering lengths with high precision. There are accurate relations between these scattering lengths and π + π − , π − K + , π + K − atoms lifetimes. The experiment on the first observation of π − K + and π + K − atoms is described. The atoms were generated in Nickel and Platinum targets hit by the PS CERN proton beam with momentum of 24 GeV/ c . Moving in the target, part of atoms break up producing characteristic π K pairs (atomic pairs) with small relative momentum Q in their c.m.s. In the experiment, we detected n A = 349 ± 62 (5.6 standard deviations) π − K + and π + K − atomic pairs. The main part of π K pairs are produced in free state. The majority of such particles are generated directly or from short-lived sources as ρ , ω and similar resonances. The electromagnetic interactions in the final state create Coulomb pairs with a known sharp dependence on Q . This effect allows to evaluate the number of these Coulomb pai...

  1. Measurement of Dead Space Fraction Upon ICU Admission Predicts Length of Stay and Clinical Outcomes Following Bidirectional Cavopulmonary Anastomosis.

    Science.gov (United States)

    Cigarroa, Claire L; van den Bosch, Sarah J; Tang, Xiaoqi; Gauvreau, Kimberlee; Baird, Christopher W; DiNardo, James A; Kheir, John Nagi

    2018-01-01

    saturation were linearly associated with prolonged ICU length of stay, hospital length of stay, duration of mechanical ventilation, and duration of thoracic drainage (p space fraction in excess of 0.28 or arterial oxyhemoglobin saturation less than 78% upon ICU admission indicates an increased likelihood of requiring intervention prior to hospital discharge. Increasing alveolar dead space fraction and decreasing arterial oxyhemoglobin saturation are associated with increased lengths of stay.

  2. Effects of correlations between particle longitudinal positions and transverse plane on bunch length measurement: a case study on GBS electron LINAC at ELI-NP

    Science.gov (United States)

    Sabato, L.; Arpaia, P.; Cianchi, A.; Liccardo, A.; Mostacci, A.; Palumbo, L.; Variola, A.

    2018-02-01

    In high-brightness LINear ACcelerators (LINACs), electron bunch length can be measured indirectly by a radio frequency deflector (RFD). In this paper, the accuracy loss arising from non-negligible correlations between particle longitudinal positions and the transverse plane (in particular the vertical one) at RFD entrance is analytically assessed. Theoretical predictions are compared with simulation results, obtained by means of ELEctron Generation ANd Tracking (ELEGANT) code, in the case study of the gamma beam system (GBS) at the extreme light infrastructure—nuclear physics (ELI-NP). In particular, the relative error affecting the bunch length measurement, for bunches characterized by both energy chirp and fixed correlation coefficients between longitudinal particle positions and the vertical plane, is reported. Moreover, the relative error versus the correlation coefficients is shown for fixed RFD phase 0 rad and π rad. The relationship between relative error and correlations factors can help the decision of using the bunch length measurement technique with one or two vertical spot size measurements in order to cancel the correlations contribution. In the case of the GBS electron LINAC, the misalignment of one of the quadrupoles before the RFD between  ‑2 mm and 2 mm leads to a relative error less than 5%. The misalignment of the first C-band accelerating section between  ‑2 mm and 2 mm could lead to a relative error up to 10%.

  3. Educational attainment but not measures of current socioeconomic circumstances are associated with leukocyte telomere length in healthy older men and women.

    Science.gov (United States)

    Steptoe, Andrew; Hamer, Mark; Butcher, Lee; Lin, Jue; Brydon, Lena; Kivimäki, Mika; Marmot, Michael; Blackburn, Elizabeth; Erusalimsky, Jorge D

    2011-10-01

    Low socioeconomic status (SES) may be associated with accelerated biological aging, but findings relating SES with telomere length have been inconsistent. We tested the hypotheses that shorter telomere length and telomerase activity would be related more robustly to education, an early life indicator of socioeconomic position, than to current indicators of socioeconomic circumstances. Healthy men and women aged 53-76 years from the Whitehall II epidemiological cohort provided blood samples from which telomere length was assessed in 448 and telomerase activity in 416. Educational attainment was classified into four levels, while household income and grade of employment were measured as indicators of current socioeconomic circumstances. Age, gender, blood pressure, glycated hemoglobin, high density lipoprotein cholesterol, smoking, body mass index and physical activity were included as covariates. We found that lower educational attainment was associated with shorter telomere length after controlling statistically for biological and behavioral covariates. Neither household income nor employment grade was related to telomere length. The association between telomere length and education remained significant after adjusting for current socioeconomic circumstances. In men, highest levels of telomerase activity were found in the lowest education group. We conclude that low SES defined in terms of education but not current socioeconomic circumstances is associated with shortened telomeres. Low educational attainment may be an indicator of long-term SES trajectories, and be associated with accumulated allostatic load resulting in telomere shortening. Education may also promote problem-solving skills leading to reduced biological stress responsivity, with favorable consequences for biological aging. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Prediction of preterm birth in multiple pregnancies: development of a multivariable model including cervical length measurement at 16 to 21 weeks' gestation.

    Science.gov (United States)

    van de Mheen, Lidewij; Schuit, Ewoud; Lim, Arianne C; Porath, Martina M; Papatsonis, Dimitri; Erwich, Jan J; van Eyck, Jim; van Oirschot, Charlotte M; Hummel, Piet; Duvekot, Johannes J; Hasaart, Tom H M; Groenwold, Rolf H H; Moons, Karl G M; de Groot, Christianne J M; Bruinse, Hein W; van Pampus, Maria G; Mol, Ben W J

    2014-04-01

    To develop a multivariable prognostic model for the risk of preterm delivery in women with multiple pregnancy that includes cervical length measurement at 16 to 21 weeks' gestation and other variables. We used data from a previous randomized trial. We assessed the association between maternal and pregnancy characteristics including cervical length measurement at 16 to 21 weeks' gestation and time to delivery using multivariable Cox regression modelling. Performance of the final model was assessed for the outcomes of preterm and very preterm delivery using calibration and discrimination measures. We studied 507 women, of whom 270 (53%) delivered models for preterm and very preterm delivery had a c-index of 0.68 (95% CI 0.63 to 0.72) and 0.68 (95% CI 0.62 to 0.75), respectively, and showed good calibration. In women with a multiple pregnancy, the risk of preterm delivery can be assessed with a multivariable model incorporating cervical length and other predictors.

  5. Vertebrae length and ultra-structure measurements of collagen fibrils and mineral content in the vertebrae of lordotic gilthead seabreams (Sparus aurata).

    Science.gov (United States)

    Berillis, Panagiotis; Panagiotopoulos, Nikolaos; Boursiaki, Vaia; Karapanagiotidis, Ioannis T; Mente, Eleni

    2015-08-01

    Skeletal deformities of gilthead seabream (Sparus aurata) are a major factor affecting the production cost, the external morphology and survival and growth of the fish. Adult individuals of S. aurata were collected from a commercial fish farm in Greece and were divided into two groups: one with the presence of lordosis, a skeletal deformity, and one without any skeletal deformity. Fishes were X-rayed, and cervical, abdominal and caudal vertebrae lengths were measured. Vertebrae were taken from the site of the vertebral column where lordosis occurred. One part was decalcified and prepared for collagen examination with transmission electron microscopy, and the rest were incinerated, and the Ca and P contents were measured. The stoichiometries of the samples were obtained by EDS (Energy Dispersive Spectroscopy). The same procedure was followed for fish without skeletal deformities (vertebrae were taken from the middle region of the vertebral column). The decalcified vertebrae parts were examined with TEM, collagen micrographs were taken and the fibrils' periods and diameters were measured. There were no significant differences for both Ca and P or the collagen fibrils' periods between the two fish groups. The mean lengths of the cervical, abdominal and caudal vertebrae where lordosis occurred were similar to the lengths of the respective regions of the individuals without the skeletal deformity. The TEM examination showed a significantly smaller mean vertebrae collagen fibril diameter from the fishes with lordosis compared with those from the controls, revealing the significance of collagen to bone structure. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Is measurement of cervical length an accurate predictive tool in women with a history of preterm delivery who present with threatened preterm labor?

    Science.gov (United States)

    Melamed, N; Hiersch, L; Meizner, I; Bardin, R; Wiznitzer, A; Yogev, Y

    2014-12-01

    To determine whether sonographically measured cervical length is an effective predictive tool in women with threatened preterm labor and a history of past spontaneous preterm delivery. This was a retrospective cohort study of all women with singleton pregnancies who presented with preterm labor at less than 34 + 0 weeks' gestation and underwent sonographic measurement of cervical length in a tertiary medical center between 2007 and 2012. The accuracy of cervical length in predicting preterm delivery was compared between women with and those without a history of spontaneous preterm delivery. Women with risk factors for preterm delivery other than a history of preterm delivery were excluded from both groups. Overall, 1023 women who presented with preterm labor met the study criteria, of whom 136 (13.3%) had a history of preterm delivery (past-PTD group) and 887 (86.7%) had no risk factors for preterm delivery (low-risk group). The rate of preterm delivery was significantly higher for women with a history of preterm delivery (36.8% vs 22.5%; P delivery interval in low-risk women (r = 0.32, P delivery (r = 0.07, P = 0.4). On multivariable analysis, cervical length was independently associated with the risk of preterm delivery for women in the low-risk group but not for women with a history of previous preterm delivery. For women with previous preterm delivery who presented with threatened preterm labor, cervical length failed to distinguish between those who did and those who did not deliver prematurely (area under the receiver-operating characteristics curve range, 0.475-0.506). When using standardized thresholds, the sensitivity and specificity of cervical length for the prediction of preterm delivery were significantly lower in women with previous preterm delivery than in women with no risk factors for preterm delivery. Cervical length appears to be of limited value in the prediction of preterm delivery among women with threatened preterm labor

  7. Repeated sprint ability and stride kinematics are altered following an official match in national-level basketball players.

    Science.gov (United States)

    Delextrat, A; Baliqi, F; Clarke, N

    2013-04-01

    The aim of the study was to investigate the effects of playing an official national-level basketball match on repeated sprint ability (RSA) and stride kinematics. Nine male starting basketball players (22.8±2.2 years old, 191.3±5.8 cm, 88±10.3 kg, 12.3±4.6% body fat) volunteered to take part. Six repetitions of maximal 4-s sprints were performed on a non-motorised treadmill, separated by 21-s of passive recovery, before and immediately after playing an official match. Fluid loss, playing time, and the frequencies of the main match activities were recorded. The peak, mean, and performance decrement for average and maximal speed, acceleration, power, vertical and horizontal forces, and stride parameters were calculated over the six sprints. Differences between pre- and post-match were assessed by student t-tests. Significant differences between pre- and post-tests were observed in mean speed (-3.3%), peak and mean horizontal forces (-4.3% and -17.4%), peak and mean vertical forces (-3.4% and -3.7%), contact time (+7.3%), stride duration (+4.6%) and stride frequency (-4.0%), (Pvertical force were significantly correlated to fluid loss and sprint, jump and shuffle frequencies (P<0.05). These results highlight that the impairment in repeated sprint ability depends on the specific activities performed, and that replacing fluid loss through sweating during a match is crucial.

  8. Validation of Distal Limb Mounted Imu Sensors for Stride Detection and Locomotor Quantification in Warmblood Horses at Walk and Trot

    NARCIS (Netherlands)

    Serra Braganca, F.M.; Vernooij, J.C.M.; René van Weeren, P.; Back, Wim

    Reasons for performing study: IMU-sensor based techniques arebecoming more popular in horses as a tool for objective locomotorassessment. Using currently proposed methods only limited informationabout stride variables can be obtained for walk and trot.Objectives: To describe, evaluate and validate a

  9. Comparison of four measures in reducing length of stay in burns: An Asian centre's evolved multimodal burns protocol.

    Science.gov (United States)

    Chong, Si Jack; Kok, Yee Onn; Choke, Abby; Tan, Esther W X; Tan, Kok Chai; Tan, Bien-Keem

    2017-09-01

    Multidisciplinary burns care is constantly evolving to improve outcomes given the numerous modalities available. We examine the use of Biobrane, micrografting, early renal replacement therapy and a strict target time of surgery within 24h of burns on improving outcomes of length of stay, duration of surgery, mean number of surgeries and number of positive tissue cultures in a tertiary burns centre. A post-implementation prospective cohort of inpatient burns patients from 2014 to 2015 (n=137) was compared against a similar pre-implementation cohort from 2013 to 2014 (n=93) using REDCAP, an electronic database. There was no statistically significant difference for comorbidities, age and percentage (%) TBSA between the new protocol and control groups. The protocol group had shorter mean time to surgery (23.5-38.5h) (pmicrograft/allograft, early CRRT and surgery within 24h were successfully introduced. These are useful adjuncts in the armamentarium to be considered for any burns centre. Copyright © 2017. Published by Elsevier Ltd.

  10. Telomere length and depression

    DEFF Research Database (Denmark)

    Wium-Andersen, Marie Kim; Ørsted, David Dynnes; Rode, Line

    2017-01-01

    BACKGROUND: Depression has been cross-sectionally associated with short telomeres as a measure of biological age. However, the direction and nature of the association is currently unclear. AIMS: We examined whether short telomere length is associated with depression cross-sectionally as well...... as prospectively and genetically. METHOD: Telomere length and three polymorphisms, TERT, TERC and OBFC1, were measured in 67 306 individuals aged 20-100 years from the Danish general population and associated with register-based attendance at hospital for depression and purchase of antidepressant medication....... RESULTS: Attendance at hospital for depression was associated with short telomere length cross-sectionally, but not prospectively. Further, purchase of antidepressant medication was not associated with short telomere length cross-sectionally or prospectively. Mean follow-up was 7.6 years (range 0...

  11. Impact of stride-coupled gaze shifts of walking blowflies on the neuronal representation of visual targets

    Directory of Open Access Journals (Sweden)

    Daniel eKress

    2014-09-01

    Full Text Available During locomotion animals rely heavily on visual cues gained from the environment to guide their behavior. Examples are basic behaviors like collision avoidance or the approach to a goal. The saccadic gaze strategy of flying flies, which separates translational from rotational phases of locomotion, has been suggested to facilitate the extraction of environmental information, because only image flow evoked by translational self-motion contains relevant distance information about the surrounding world. In contrast to the translational phases of flight during which gaze direction is kept largely constant, walking flies experience continuous rotational image flow that is coupled to their stride-cycle. The consequences of these self-produced image shifts for the extraction of environmental information are still unclear. To assess the impact of stride-coupled image shifts on visual information processing, we performed electrophysiological recordings from the HSE cell, a motion sensitive wide-field neuron in the blowfly visual system. This cell has been concluded to play a key role in mediating optomotor behavior, self-motion estimation and spatial information processing. We used visual stimuli that were based on the visual input experienced by walking blowflies while approaching a black vertical bar. The response of HSE to these stimuli was dominated by periodic membrane potential fluctuations evoked by stride-coupled image shifts. Nevertheless, during the approach the cell’s response contained information about the bar and its background. The response components evoked by the bar were larger than the responses to its background, especially during the last phase of the approach. However, as revealed by targeted modifications of the visual input during walking, the extraction of distance information on the basis of HSE responses is much impaired by stride-coupled retinal image shifts. Possible mechanisms that may cope with these stride

  12. The STRIDE weight loss and lifestyle intervention for individuals taking antipsychotic medications: a randomized trial.

    Science.gov (United States)

    Green, Carla A; Yarborough, Bobbi Jo H; Leo, Michael C; Yarborough, Micah T; Stumbo, Scott P; Janoff, Shannon L; Perrin, Nancy A; Nichols, Greg A; Stevens, Victor J

    2015-01-01

    The STRIDE study assessed whether a lifestyle intervention, tailored for individuals with serious mental illnesses, reduced weight and diabetes risk. The authors hypothesized that the STRIDE intervention would be more effective than usual care in reducing weight and improving glucose metabolism. The study design was a multisite, parallel two-arm randomized controlled trial in community settings and an integrated health plan. Participants who met inclusion criteria were ≥18 years old, were taking antipsychotic agents for ≥30 days, and had a body mass index ≥27. Exclusions were significant cognitive impairment, pregnancy/breastfeeding, recent psychiatric hospitalization, bariatric surgery, cancer, heart attack, or stroke. The intervention emphasized moderate caloric reduction, the DASH (Dietary Approaches to Stop Hypertension) diet, and physical activity. Blinded staff collected data at baseline, 6 months, and 12 months. Participants (men, N=56; women, N=144; mean age=47.2 years [SD=10.6]) were randomly assigned to usual care (N=96) or a 6-month weekly group intervention plus six monthly maintenance sessions (N=104). A total of 181 participants (90.5%) completed 6-month assessments, and 170 (85%) completed 12-month assessments, without differential attrition. Participants attended 14.5 of 24 sessions over 6 months. Intent-to-treat analyses revealed that intervention participants lost 4.4 kg more than control participants from baseline to 6 months (95% CI=-6.96 kg to -1.78 kg) and 2.6 kg more than control participants from baseline to 12 months (95% CI=-5.14 kg to -0.07 kg). At 12 months, fasting glucose levels in the control group had increased from 106.0 mg/dL to 109.5 mg/dL and decreased in the intervention group from 106.3 mg/dL to 100.4 mg/dL. No serious adverse events were study-related; medical hospitalizations were reduced in the intervention group (6.7%) compared with the control group (18.8%). Individuals taking antipsychotic medications can lose

  13. Stimulant Reduction Intervention using Dosed Exercise (STRIDE - CTN 0037: Study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Morris David W

    2011-09-01

    Full Text Available Abstract Background There is a need for novel approaches to the treatment of stimulant abuse and dependence. Clinical data examining the use of exercise as a treatment for the abuse of nicotine, alcohol, and other substances suggest that exercise may be a beneficial treatment for stimulant abuse, with direct effects on decreased use and craving. In addition, exercise has the potential to improve other health domains that may be adversely affected by stimulant use or its treatment, such as sleep disturbance, cognitive function, mood, weight gain, quality of life, and anhedonia, since it has been shown to improve many of these domains in a number of other clinical disorders. Furthermore, neurobiological evidence provides plausible mechanisms by which exercise could positively affect treatment outcomes. The current manuscript presents the rationale, design considerations, and study design of the National Institute on Drug Abuse (NIDA Clinical Trials Network (CTN CTN-0037 Stimulant Reduction Intervention using Dosed Exercise (STRIDE study. Methods/Design STRIDE is a multisite randomized clinical trial that compares exercise to health education as potential treatments for stimulant abuse or dependence. This study will evaluate individuals diagnosed with stimulant abuse or dependence who are receiving treatment in a residential setting. Three hundred and thirty eligible and interested participants who provide informed consent will be randomized to one of two treatment arms: Vigorous Intensity High Dose Exercise Augmentation (DEI or Health Education Intervention Augmentation (HEI. Both groups will receive TAU (i.e., usual care. The treatment arms are structured such that the quantity of visits is similar to allow for equivalent contact between groups. In both arms, participants will begin with supervised sessions 3 times per week during the 12-week acute phase of the study. Supervised sessions will be conducted as one-on-one (i.e., individual sessions

  14. Measurement of muscle length-related electromyography activity of the hip flexor muscles to determine individual muscle contributions to the hip flexion torque.

    Science.gov (United States)

    Jiroumaru, Takumi; Kurihara, Toshiyuki; Isaka, Tadao

    2014-01-01

    This study aimed to investigate muscle length-related electromyography (EMG) of the iliopsoas (IL) and other hip flexor muscles to determine individual muscle contributions to the hip flexion torque. Ten healthy sedentary young men participated in the EMG experiment. A subgroup of six subjects underwent a magnetic resonance imaging (MRI) measurement to confirm the region of the skin over the IL. Surface EMG signals were sampled from the IL, rectus femoris (RF), sartorius (SA), and tensor fasciae latae (TFL) using an active electrode. The subjects performed maximum voluntary isometric hip flexion with the right hip joint set at -10°, 0°, 30°, and 60°. The root mean square (RMS) value for the TFL at 30° (0.81 ± 0.19, p muscle length changes were significantly correlated in the IL (r =0.39, p muscles.

  15. Cervical length measurement in nulliparous women at term by ultrasound & its relationship to spontaneous onset of labour

    Directory of Open Access Journals (Sweden)

    Joydev Mukherji

    2017-01-01

    Interpretation & conclusions: Inter-individual variations in CL and in CL changes were large. Thus, it was not practical to predict spontaneous onset of labour by sonographic CL measurement near term. Post-dated pregnancy may be predicted with limited success. Further studies should explore other parameters, in addition to CL.

  16. Endüstride Su Güvenliği, Dezenfeksiyon ve Sanitasyonu

    Directory of Open Access Journals (Sweden)

    Ayla ÜNVER

    2011-01-01

    Full Text Available Gelişmekte olan ülkelerde, her yıl suyla bulaşan hastalıklar yüzünden milyonlarca kişi ölmekte, milyarlarca kişi de hasta olmaktadır. Dünya nüfusunun artması sonucu, içme ve kullanma suyu ihtiyacı hızla artmıştır. Ayrıca çevre kirliliği su kaynaklarında kirlenmeye sebep olmuştur. Su endüstride en çok kullanılan hammaddelerden biridir. Su kalitesi standartları ülke yönetimleri ve uluslararası standartlarca belirlenir. Suyun saflaştırılması; istenmeyen kimyasalların, diğer materyallerin ve biyolojik kontaminantların sudan uzaklaştırılması prosesidir. Su saflaştırma, sağlıklı dağıtım sistemleri, su dezenfeksiyon prosesleri, medikal, gıda sektörü, kimyasal ve endüstriyel uygulamalar için önemli gerekliliklerdir.

  17. Design and validation of a 3D virtual reality desktop system for sonographic length and volume measurements in early pregnancy evaluation.

    Science.gov (United States)

    Baken, Leonie; van Gruting, Isabelle M A; Steegers, Eric A P; van der Spek, Peter J; Exalto, Niek; Koning, Anton H J

    2015-03-01

    To design and validate a desktop virtual reality (VR) system, for presentation and assessment of volumetric data, based on commercially off-the-shelf hardware as an alternative to a fully immersive CAVE-like I-Space VR system. We designed a desktop VR system, using a three-dimensional (3D) monitor and a six degrees-of-freedom tracking system. A personal computer uses the V-Scope (Erasmus MC, Rotterdam, The Netherlands) volume-rendering application, developed for the I-Space, to create a hologram of volumetric data. Inter- and intraobserver reliability for crown-rump length and embryonic volume measurements are investigated using Bland-Altman plots and intraclass correlation coefficients. Time required for the measurements was recorded. Comparing the I-Space and the desktop VR system, the mean difference for crown-rump length is -0.34% (limits of agreement -2.58-1.89, ±2.24%) and for embryonic volume -0.92% (limits of agreement -6.97-5.13, ±6.05%). Intra- and interobserver intraclass correlation coefficients of the desktop VR system were all >0.99. Measurement times were longer on the desktop VR system compared with the I-Space, but the differences were not statistically significant. A user-friendly desktop VR system can be put together using commercially off-the-shelf hardware at an acceptable price. This system provides a valid and reliable method for embryonic length and volume measurements and can be used in clinical practice. © 2014 Wiley Periodicals, Inc.

  18. Can Tai Chi training impact fractal stride time dynamics, an index of gait health, in older adults? Cross-sectional and randomized trial studies.

    Directory of Open Access Journals (Sweden)

    Brian J Gow

    Full Text Available To determine if Tai Chi (TC has an impact on long-range correlations and fractal-like scaling in gait stride time dynamics, previously shown to be associated with aging, neurodegenerative disease, and fall risk.Using Detrended Fluctuation Analysis (DFA, this study evaluated the impact of TC mind-body exercise training on stride time dynamics assessed during 10 minute bouts of overground walking. A hybrid study design investigated long-term effects of TC via a cross-sectional comparison of 27 TC experts (24.5 ± 11.8 yrs experience and 60 age- and gender matched TC-naïve older adults (50-70 yrs. Shorter-term effects of TC were assessed by randomly allocating TC-naïve participants to either 6 months of TC training or to a waitlist control. The alpha (α long-range scaling coefficient derived from DFA and gait speed were evaluated as outcomes.Cross-sectional comparisons using confounder adjusted linear models suggest that TC experts exhibited significantly greater long-range scaling of gait stride time dynamics compared with TC-naïve adults. Longitudinal random-slopes with shared baseline models accounting for multiple confounders suggest that the effects of shorter-term TC training on gait dynamics were not statistically significant, but trended in the same direction as longer-term effects although effect sizes were very small. In contrast, gait speed was unaffected in both cross-sectional and longitudinal comparisons.These preliminary findings suggest that fractal-like measures of gait health may be sufficiently precise to capture the positive effects of exercise in the form of Tai Chi, thus warranting further investigation. These results motivate larger and longer-duration trials, in both healthy and health-challenged populations, to further evaluate the potential of Tai Chi to restore age-related declines in gait dynamics.The randomized trial component of this study was registered at ClinicalTrials.gov (NCT01340365.

  19. Sub-recoil cooling up to nano-Kelvin. Direct measurement of spatial coherency length. New tests for Levy statistics

    International Nuclear Information System (INIS)

    Saubamea, B.

    1998-12-01

    This thesis presents a new method to measure the temperature of ultracold atoms from the spatial autocorrelation function of the atomic wave-packets. We thus determine the temperature of metastable helium-4 atoms cooled by velocity selective dark resonance, a method known to cool the atoms below the temperature related to the emission or the absorption of a single photon by an atom at rest, namely the recoil temperature. This cooling mechanism prepares each atom in a coherent superposition of two wave-packets with opposite mean momenta, which are initially superimposed and then drift apart. By measuring the temporal decay of their overlap, we have access to the Fourier transform of the momentum distribution of the atoms. Using this method, we can measure temperatures as low as 5 nK, 800 times as small as the recoil temperature. Moreover we study in detail the exact shape of the momentum distribution and compare the experimental results with two different theoretical approaches: a quantum Monte Carlo simulation and an analytical model based on Levy statistics. We compare the calculated line shape with the one deduced from simulations, and each theoretical model with experimental data. A very good agreement is found with each approach. We thus demonstrate the validity of the statistical model of sub-recoil cooling and give the first experimental evidence of some of its characteristics: the absence of steady-state, the self-similarity and the non Lorentzian shape of the momentum distribution of the cooled atoms. All these aspects are related to the non ergodicity of sub-recoil cooling. (author)

  20. ePAT: A simple method to tag adenylated RNA to measure poly(A)-tail length and other 3′ RACE applications

    Science.gov (United States)

    Jänicke, Amrei; Vancuylenberg, John; Boag, Peter R.; Traven, Ana; Beilharz, Traude H.

    2012-01-01

    The addition of a poly(A)-tail to the 3′ termini of RNA molecules influences stability, nuclear export, and efficiency of translation. In the cytoplasm, dynamic changes in the length of the poly(A)-tail have long been recognized as reflective of the switch between translational silence and activation. Thus, measurement of the poly(A)-tail associated with any given mRNA at steady-state can serve as a surrogate readout of its translation-state. Here, we describe a simple new method to 3′-tag adenylated RNA in total RNA samples using the intrinsic property of Escherichia coli DNA polymerase I to extend an RNA primer using a DNA template. This tag can serve as an anchor for cDNA synthesis and subsequent gene-specific PCR to assess poly(A)-tail length. We call this method extension Poly(A) Test (ePAT). The ePAT approach is as efficient as traditional Ligation-Mediated Poly(A) Test (LM-PAT) assays, avoids problems of internal priming associated with oligo-dT-based methods, and allows for the accurate analysis of both the poly(A)-tail length and alternate 3′ UTR usage in 3′ RACE applications. PMID:22543866

  1. Comparison of anterior segment measurements using Sirius Topographer® and Nidek Axial Length-Scan® with assessing repeatability in patients with cataracts

    Directory of Open Access Journals (Sweden)

    Resat Duman

    2018-01-01

    Full Text Available Purpose: The purpose of this study is to evaluate anterior segment measurements obtained using CSO Sirius Topographer® (CSO, Firenze, Italy and Nidek Axial Length (AL-Scan® (Nidek CO., Gamagori, Japan. Methods: A total of 43 eyes of 43 patients were included in this prospective study. The central corneal thickness (CCT, anterior chamber depth (ACD, white-to-white distance (WTW, flat keratometry (K1, steep keratometry (K2, and mean keratometry (K values were randomly measured three times with each device by the same examiner. The intraclass correlation coefficient of repeatability was analyzed. The compatibility of both devices was evaluated using the 95% limits of the agreement proposed by Bland and Altman. Results: Examiner achieved high repeatability for all parameters on each device except the WTW measured by Sirius. All measurements except WTW and K1 taken with the Sirius were higher than that taken with the Nidek AL-Scan®. The difference in CCT, ACD, and WTW values was statistically significant. Conclusion: High repeatability of the measurements was achieved on both devices. Although Km, K1, and K2 measurements of the Sirius and the AL-Scan® showed good agreement, WTW, CCT, and ACD measurements significantly differed between two devices. Thus, anterior segment measurements except for Km, K1, and K2 cannot be used interchangeably between Sirius and Nidek AL-Scan® devices.

  2. MARBLE (Multiple Antenna Radio-interferometry for Baseline Length Evaluation): Development of a Compact VLBI System for Calibrating GNSS and Electronic Distance Measurement Devices

    Science.gov (United States)

    Ichikawa, R.; Ishii, A.; Takiguchi, H.; Kimura, M.; Sekido, M.; Takefuji, K.; Ujihara, H.; Hanado, Y.; Koyama, Y.; Kondo, T.; Kurihara, S.; Kokado, K.; Kawabata, R.; Nozawa, K.; Mukai, Y.; Kuroda, J.; Ishihara, M.; Matsuzaka, S.

    2012-12-01

    We are developing a compact VLBI system with a 1.6-m diameter aperture dish in order to provide reference baseline lengths for calibration. The reference baselines are used to validate surveying instruments such as GPS and EDM and is maintained by the Geospatial Information Authority of Japan (GSI). The compact VLBI system will be installed at both ends of the reference baseline. Since the system is not sensitive enough to detect fringes between the two small dishes, we have designed a new observation concept including one large dish station. We can detect two group delays between each compact VLBI system and the large dish station based on conventional VLBI measurement. A group delay between the two compact dishes can be indirectly calculated using a simple equation. We named the idea "Multiple Antenna Radio-interferometry for Baseline Length Evaluation", or MARBLE system. The compact VLBI system is easy transportable and consists of the compact dish, a new wide-band front-end system, azimuth and elevation drive units, an IF down-converter unit, an antenna control unit (ACU), a counterweight, and a monument pillar. Each drive unit is equipped with a zero-backlash harmonic drive gearing component. A monument pillar is designed to mount typical geodetic GNSS antennas easily and an offset between the GNSS antenna reference point. The location of the azimuth-elevation crossing point of the VLBI system is precisely determined with an uncertainty of less than 0.2 mm. We have carried out seven geodetic VLBI experiments on the Kashima-Tsukuba baseline (about 54 km) using the two prototypes of the compact VLBI system between December 2009 and December 2010. The average baseline length and repeatability of the experiments is 54184874.0 ± 2.4 mm. The results are well consistent with those obtained by GPS measurements. In addition, we are now planning to use the compact VLBI system for precise time and frequency comparison between separated locations.

  3. Validation of Transient Elastography and Comparison with Spleen Length Measurement for Staging of Fibrosis and Clinical Prognosis in Primary Sclerosing Cholangitis.

    Directory of Open Access Journals (Sweden)

    Hanno Ehlken

    Full Text Available Patients with primary sclerosing cholangitis (PSC develop progressive liver fibrosis and end-stage liver disease. Non-invasive and widely available parameters are urgently needed to assess disease stage and the risk of clinical progression. Transient elastography (TE has been reported to predict fibrosis stage and disease progression. However, these results have not been confirmed in an independent cohort and comparison of TE measurement to other non-invasive means is missing.In a retrospective study we collected data from consecutive PSC patients receiving TE measurements from 2006 to 2014 (n = 139. Data from 62 patients who also underwent a liver biopsy were used to assess the performance of TE and spleen length (SL measurement for the staging of liver fibrosis. Follow-up data from this cohort (n = 130, Hamburg and another independent cohort (n = 80, Paris was used to compare TE and SL as predictors of clinical outcome applying Harrel's C calculations.TE measurement had a very good performance for the diagnosis and exclusion of higher fibrosis stages (≥F3: AUROC 0.95 and an excellent performance for the diagnosis and exclusion of cirrhosis (F4 vs. < F4: AUROC 0.98. Single-point TE measurement had very similar predictive power for patient outcome as previously published. In a combined cohort of PSC patients (n = 210, SL measurements had a similar performance as TE for the prediction of patient outcome (5 x cross-validated Harrel's C 0.76 and 0.72 for SL and TE, respectively.Baseline TE measurement has an excellent performance to diagnose higher fibrosis stages in PSC. Baseline measurements of SL and TE have similar usefulness as predictive markers for disease progression in patients with PSC.

  4. The influence of NDT-Bobath and PNF methods on the field support and total path length measure foot pressure (COP) in patients after stroke.

    Science.gov (United States)

    Krukowska, Jolanta; Bugajski, Marcin; Sienkiewicz, Monika; Czernicki, Jan

    In stroke patients, the NDT - (Bobath - Neurodevelopmental Treatment) and PNF (Proprioceptive Neuromuscular Facilitation) methods are used to achieve the main objective of rehabilitation, which aims at the restoration of maximum patient independence in the shortest possible period of time (especially the balance of the body). The aim of the study is to evaluate the effect of the NDT-Bobath and PNF methods on the field support and total path length measure foot pressure (COP) in patients after stroke. The study included 72 patients aged from 20 to 69 years after ischemic stroke with Hemiparesis. The patients were divided into 4 groups by a simple randomization. The criteria for this division were: the body side (right or left) affected by paresis and the applied rehabilitation methods. All the patients were applied the recommended kinesitherapeutic method (randomized), 35 therapy sessions, every day for a period of six weeks. Before initiation of therapy and after 6 weeks was measured the total area of the support and path length (COP (Center Of Pressure) measure foot pressure) using stabilometer platform - alpha. The results were statistically analyzed. After treatment studied traits decreased in all groups. The greatest improvement was obtained in groups with NDT-Bobath therapy. NDT-Bobath method for improving the balance of the body is a more effective method of treatment in comparison with of the PNF method. In stroke patients, the effectiveness of NDT-Bobath method does not depend on hand paresis. Copyright © 2016 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  5. Correspondence optimization in 2D standardized carotid wall thickness map by description length minimization: A tool for increasing reproducibility of 3D ultrasound-based measurements.

    Science.gov (United States)

    Chen, Yimin; Chiu, Bernard

    2016-12-01

    The previously described 2D standardized vessel-wall-plus-plaque thickness (VWT) maps constructed from 3D ultrasound vessel wall measurements using an arc-length (AL) scaling approach adjusted the geometric variability of carotid arteries and has allowed for the comparisons of VWT distributions in longitudinal and cross-sectional studies. However, this mapping technique did not optimize point correspondence of the carotid arteries investigated. The potential misalignment may lead to errors in point-wise VWT comparisons. In this paper, we developed and validated an algorithm based on steepest description length (DL) descent to optimize the point correspondence implied by the 2D VWT maps. The previously described AL approach was applied to obtain initial 2D maps for a group of carotid arteries. The 2D maps were reparameterized based on an iterative steepest DL descent approach, which consists of the following two steps. First, landmarks established by resampling the 2D maps were aligned using the Procrustes algorithm. Then, the gradient of the DL with respect to horizontal and vertical reparameterizations of each landmark on the 2D maps was computed, and the 2D maps were subsequently deformed in the direction of the steepest descent of DL. These two steps were repeated until convergence. The quality of the correspondence was evaluated in a phantom study and an in vivo study involving ten carotid arteries enrolled in a 3D ultrasound interscan variability study. The correspondence quality was evaluated in terms of the compactness and generalization ability of the statistical shape model built based on the established point correspondence in both studies. In the in vivo study, the effect of the proposed algorithm on interscan variability of VWT measurements was evaluated by comparing the percentage of landmarks with statistically significant VWT-change before and after point correspondence optimization. The statistical shape model constructed with optimized

  6. Comparison of fiber length analyzers

    Science.gov (United States)

    Don Guay; Nancy Ross Sutherland; Walter Rantanen; Nicole Malandri; Aimee Stephens; Kathleen Mattingly; Matt Schneider

    2005-01-01

    In recent years, several fiber new fiber length analyzers have been developed and brought to market. The new instruments provide faster measurements and the capability of both laboratory and on-line analysis. Do the various fiber analyzers provide the same length, coarseness, width, and fines measurements for a given fiber sample? This paper provides a comparison of...

  7. Measurement of Pion and Proton Response and Longitudinal Shower Profiles up to 20 Nuclear Interaction Lengths with the ATLAS Tile Calorimeter

    CERN Document Server

    Adragna, P; Anderson, K; Antonaki, A; Arabidze, A; Batkova, L; Batusov, V; Beck, H P; Bergeaas Kuutmann, E; Biscarat, C; Blanchot, G; Bogush, A; Bohm, C; Boldea, V; Bosman, M; Bromberg, C; Budagov, J; Burckhart-Chromek, D; Caprini, M; Caloba, L; Calvet, D; Carli, T; Carvalho, J; Cascella, M; Castelo, J; Castillo, M V; Cavalli-Sforza, M; Cavasinni, V; Cerqueira, A S; Clement, C; Cobal, M; Cogswell, F; Constantinescu, S; Costanzo, D; Corso-Radu, A; Cuenca, C; Damazio, D O; Davidek, T; De, K; Del Prete, T; Di Girolamo, B; Dita, S; Djobava, T; Dobson, M; Dotti, A; Downing, R; Efthymiopoulos, I; Eriksson, D; Errede, D; Errede, S; Farbin, A; Fassouliotis, D; Febbraro, R; Fenyuk, A; Ferdi, C; Ferrer, A; Flaminio, V; Francis, D; Fullana, E; Gadomski, S; Gameiro, S; Garde, V; Gellerstedt, K; Giakoumopoulou, V; Gildemeister, O; Gilewsky, V; Giokaris, N; Gollub, N; Gomes, A; Gonzalez, V; Gorini, B; Grenier, P; Gris, P; Gruwe, M; Guarino, V; Guicheney, C; Gupta, A; Haeberli, C; Hakobyan, H; Haney, M; Hellman, S; Henriques, A; Higon, E; Holmgren, S; Hurwitz, M; Huston, J; Iglesias, C; Isaev, A; Jen-La Plante, I; Jon-And, K; Joos, M; Junk, T; Karyukhin, A; Kazarov, A; Khandanyan, H; Khramov, J; Khubua, J; Kolos, S; Korolkov, I; Krivkova, P; Kulchitsky, Y; Kurochkin, Yu; Kuzhir, P; LeCompte, T; Lefevre, R; Lehmann, G; Leitner, R; Lembesi, M; Lesser, J; Li, J; Liablin, M; Lokajicek, M; Lomakin, Y; Lupi, A; Maidanchik, C; Maio, A; Makouski, M; Maliukov, S; Manousakis, A; Mapelli, L; Marques, C; Marroquim, F; Martin, F; Mazzoni, E; Merritt, F; Miagkov, A; Miller, R; Minashvili, I; Miralles, L; Montarou, G; Mosidze, M; Myagkov, A; Nemecek, S; Nessi, M; Nodulman, L; Nordkvist, B; Norniella, O; Novakova, J; Onofre, A; Oreglia, M; Pallin, D; Pantea, D; Petersen, J; Pilcher, J; Pina, J; Pinhao, J; Podlyski, F; Portell Bueso, X; Poveda, J; Pribyl, L; Price, L E; Proudfoot, J; Ramstedt, M; Richards, R; Roda, C; Romanov, V; Rosnet, P; Roy, P; Ruiz, A; Rumiantsev, V; Russakovich, N; Salto, O; Salvachua, B; Sanchis, E; Sanders, H; Santoni, C; Saraiva, J G; Sarri, F; Satsunkevitch, I; Says, L P; Schlager, G; Schlereth, J; Seixas, J M; Sellden, B; Shalanda, N; Shevtsov, P; Shochet, M; Silva, J; Da Silva, P; Simaitis, V; Simonyan, M; Sissakian, A; Sjolin, J; Solans, C; Solodkov, A; Soloviev, I; Solovyanov, O; Sosebee, M; Spano, F; Stanek, R; Starchenko, E; Starovoitov, P; Stavina, P; Suk, M; Sykora, I; Tang, F; Tas, P; Teuscher, R; Tokar, S; Topilin, N; Torres, J; Tremblet, L; Tsiareshka, P; Tylmad, M; Underwood, D; Unel, G; Usai, G; Valero, A; Valkar, S; Valls, J A; Vartapetian, A; Vazeille, F; Vichou, I; Vinogradov, V; Vivarelli, I; Volpi, M; White, A; Zaitsev, A; Zenine, A; Zenis, T

    2010-01-01

    The response of pions and protons in the energy range of 20 to 180 GeV produced at CERN's SPS H8 test beam line in the ATLAS iron-scintillator Tile hadron calorimeter has been measured. The test-beam configuration allowed to measure the longitudinal shower development for pions and protons up to 20 nuclear interaction lengths. It is found that pions penetrate deeper in the calorimeter than protons. However, protons induce showers that are wider laterally to the direction of the impinging particle. Including the measured total energy response, the pion to proton energy ratio and the resolution, all observations are consistent with a higher electromagnetic energy fraction in pion induced showers. The data are compared with GEANT4 simulations using several hadronic physics lists. The measured longitudinal shower profiles are described by an analytical shower parameterization within an accuracy of 5-10%. The amount of energy leaking out behind the calorimeter is determined and parameterised as a function of the b...

  8. Lengths of Schwabe cycles in the seventh and eighth centuries indicated by precise measurement of carbon-14 content in tree rings

    Science.gov (United States)

    Miyake, Fusa; Masuda, Kimiaki; Nakamura, Toshio

    2013-12-01

    (14C) is produced in the atmosphere by galactic cosmic rays, which are modulated by solar magnetic activity. Its content in tree rings is retained and provides a record of past cosmic ray intensity and solar activity. We have measured, with 2 year resolution, the 14C content in Japanese cedar tree rings for the period A.D. 600 to 760, which includes a small grand solar minimum in the seventh to eighth centuries. Periodicity analysis of the 14C data shows that there is a component in the frequency band of the Schwabe cycle, with a period of 12-13 years continuing throughout the minimum. This is the fourth case in which an increase in the length of the Schwabe cycle has been observed in a grand solar minimum, after the Maunder Minimum, the Spörer Minimum, and the Fourth Century B.C. Minimum.

  9. Measurement of the penetration depth and coherence length of MgB2 in all directions using transmission electron microscopy

    DEFF Research Database (Denmark)

    Loudon, J. C.; Yazdi, Sadegh; Kasama, Takeshi

    2015-01-01

    lengths. This gave penetration depths Lambda(ab) = 100 +/- 35 nm and Lambda(c) = 120 +/- 15 nm at 10.8 K in a field of 4.8 mT. The large error in Lambda(ab) is a consequence of tilting the sample about a and had it been tilted about c, the errors on Lambda(ab) and Lambda(c) would be reversed. Thus...... gives Lambda(ab) = 107 +/- 8 nm, Lambda(c) = 120 +/- 15 nm, xi(ab) = 39 +/- 11 nm, and xi(c) = 35 +/- 10 nm, which agree well with measurements made using other techniques. The experiment required two days to conduct and does not require large-scale facilities. It was performed on a very small sample...

  10. The operational implications of donor behaviors following enrollment in STRIDE (Strategies to Reduce Iron Deficiency in blood donors).

    Science.gov (United States)

    Cable, Ritchard G; Birch, Rebecca J; Spencer, Bryan R; Wright, David J; Bialkowski, Walter; Kiss, Joseph E; Rios, Jorge; Bryant, Barbara J; Mast, Alan E

    2017-10-01

    Donor behaviors in STRIDE (Strategies to Reduce Iron Deficiency), a trial to reduce iron deficiency, were examined. Six hundred ninety-two frequent donors were randomized to receive either 19 or 38 mg iron for 60 days or an educational letter based on their predonation ferritin. Compliance with assigned pills, response to written recommendations, change in donation frequency, and future willingness to take iron supplements were examined. Donors who were randomized to receive iron pills had increased red blood cell donations and decreased hemoglobin deferrals compared with controls or with pre-STRIDE donations. Donors who were randomized to receive educational letters had fewer hemoglobin deferrals compared with controls. Of those who received a letter advising of low ferritin levels with recommendations to take iron supplements or delay future donations, 57% reported that they initiated iron supplementation, which was five times as many as those who received letters lacking a specific recommendation. The proportion reporting delayed donation was not statistically different (32% vs. 20%). Of donors who were assigned pills, 58% reported taking them "frequently," and forgetting was the primary reason for non-compliance. Approximately 80% of participants indicated that they would take iron supplements if provided by the center. Donors who were assigned iron pills had acceptable compliance, producing increased red blood cell donations and decreased low hemoglobin deferrals compared with controls or with pre-STRIDE rates. The majority of donors assigned to an educational letter took action after receiving a low ferritin result, with more donors choosing to take iron than delay donation. Providing donors with information on iron status with personalized recommendations was an effective alternative to directly providing iron supplements. © 2017 AABB.

  11. Measuring the amount of serum albumin in burn patients and the relationship between the burned area and length of hospital stay

    Directory of Open Access Journals (Sweden)

    Maryam Roham

    2017-08-01

    Methods: This cross-sectional study was conducted on patients aged over 16 years who referred to the Motahari Hospital of September 2014 to February 2015 in the first 24 hours of their referral. The amount of Albumin was measured in two groups of discharged patients and patients who died while hospitalized, one week after hospital stay and in the time of discharge and death; and its relationship in terms of each other was determined by statistical analysis. We also assessed the relationship between burn and duration of hospital stay with the amount of Albumin on the day of patient’s admission. Results: This study showed that the average amount of albumin in the group of discharged patients in the time of admission, one week after and during admission was significantly higher than the group of expired patients (P<0.0001. Also there was a significant relation between the burned area and the amount of albumin (P<0.0001. The more the burned area, the less the amount of Albumin. But there was no significant relationship between the amount of albumin with age and length of hospital stay. Conclusion: Measuring the level of Albumin is one of the yardsticks that can be used for prognosis of recovery or death of burn patients, and its assessment at regular intervals in burn patients is essential.

  12. Stride lengths, speed and energy costs in walking of Australopithecus afarensis: using evolutionary robotics to predict locomotion of early human ancestors

    OpenAIRE

    Sellers, William I; Cain, Gemma M; Wang, Weijie; Crompton, Robin H

    2005-01-01

    This paper uses techniques from evolutionary robotics to predict the most energy-efficient upright walking gait for the early human relative Australopithecus afarensis, based on the proportions of the 3.2 million year old AL 288-1 ‘Lucy’ skeleton, and matches predictions against the nearly contemporaneous (3.5–3.6 million year old) Laetoli fossil footprint trails. The technique creates gaits de novo and uses genetic algorithm optimization to search for the most efficient patterns of simulated...

  13. 7 Length-weight relationship

    African Journals Online (AJOL)

    Administrator

    Length-weight measurements were taken from well-preserved fish specimens from which stomachs were extracted for the analysis of the food contents, using frequency of occurrence, numerical and gravimetric methods, as well as index of relative importance. The length-frequency analysis showed a size distribution with a ...

  14. A novel method for patient exit and entrance dose prediction based on water equivalent path length measured with an amorphous silicon electronic portal imaging device

    International Nuclear Information System (INIS)

    Kavuma, Awusi; Glegg, Martin; Metwaly, Mohamed; Currie, Garry; Elliott, Alex

    2010-01-01

    In vivo dosimetry is one of the quality assurance tools used in radiotherapy to monitor the dose delivered to the patient. Electronic portal imaging device (EPID) images for a set of solid water phantoms of varying thicknesses were acquired and the data fitted onto a quadratic equation, which relates the reduction in photon beam intensity to the attenuation coefficient and material thickness at a reference condition. The quadratic model is used to convert the measured grey scale value into water equivalent path length (EPL) at each pixel for any material imaged by the detector. For any other non-reference conditions, scatter, field size and MU variation effects on the image were corrected by relative measurements using an ionization chamber and an EPID. The 2D EPL is linked to the percentage exit dose table, for different thicknesses and field sizes, thereby converting the plane pixel values at each point into a 2D dose map. The off-axis ratio is corrected using envelope and boundary profiles generated from the treatment planning system (TPS). The method requires field size, monitor unit and source-to-surface distance (SSD) as clinical input parameters to predict the exit dose, which is then used to determine the entrance dose. The measured pixel dose maps were compared with calculated doses from TPS for both entrance and exit depth of phantom. The gamma index at 3% dose difference (DD) and 3 mm distance to agreement (DTA) resulted in an average of 97% passing for the square fields of 5, 10, 15 and 20 cm. The exit dose EPID dose distributions predicted by the algorithm were in better agreement with TPS-calculated doses than phantom entrance dose distributions.

  15. Uniqueness in the determination of vibration sources in rectangular Germain–Lagrange plates using displacement measurements over line segments with arbitrary small length

    International Nuclear Information System (INIS)

    Kawano, Alexandre

    2013-01-01

    The theme of this work is related to the field of vibration and source detection, which is important in naval, aerospace and civil engineering industries. The detection of unexpected vibration sources, in general, signals malfunctioning, or even an undesired presence in the case of defense systems. The focus will be on thin plates, which are among the basic building blocks of large complex structures. Here, we consider loads acting on a rectangular plate R of the product form g(t)Q(x), where the function of time g has a continuous first derivative and the spatial load distribution Q is a square-integrable function over R. We prove that the observation of the displacement of a line segment with arbitrary length parallel to one of the sides of the plate is enough for the determination of Q, provided that the interval of time is long enough. We also prove that the normal derivative along a side of the rectangle measured for an arbitrarily small interval of time is sufficient to determine the spatial load distribution Q. The method used to obtain the results is based on the series decomposition of the dynamic response and an analysis of the almost periodic distribution that arises from it. (paper)

  16. Decompression of tension pneumothoraces in Asian trauma patients: greater success with lateral approach and longer catheter lengths based on computed tomography chest wall measurements.

    Science.gov (United States)

    Goh, S; Xu, W R; Teo, L T

    2017-10-03

    Our study aims to compare the anterior and lateral approaches for needle thoracostomy (NT) and determine the adequacy of catheter lengths used for NT in Asian trauma patients based on computed tomography chest wall measurements. A retrospective review of chest computed tomography scans of 583 Singaporean trauma patients during period of 2011-2015 was conducted. Four measurements of chest wall thickness (CWT) were taken at the second intercostal space, midclavicular line and fifth intercostal space, midaxillary line bilaterally. Measurements were from the superficial skin layer of the chest wall to the pleural space. Successful NT was defined radiologically as CWT ≤ 5 cm. There were 593 eligible subjects. Mean age was 49.1 years (49.1 ± 21.0). Majority were males (77.0%) and Chinese (70.2%). Mean CWT for the anterior approach was 4.04 cm (CI 3.19-4.68) on the left and 3.92 cm (CI 3.17-4.63) on the right. Mean CWT for the lateral approach was 3.52 cm (CI 2.52-4.36) on the left, and 3.62 cm (CI 3.65-4.48) on the right. Mean CWT was shorter in the lateral approach by 0.52 cm on the left and 0.30 cm on the right (p = 0.001). With a 5.0 cm catheter in the anterior approach, 925 out of 1186 sites (78.8%) will have adequate NT as compared to 98.2% with a 7.0 cm catheter. Similarly, in the lateral approach 1046 out of 1186 (88.2%) will have adequate NT as compared to 98.5% with a 7.0 cm catheter. Obese subjects had significantly higher mean CWT in both approaches (p = 0.001). There was moderate correlation between BMI and CWT in the anterior approach, r 2  = 0.529 as compared to the lateral approach, r 2  = 0.244. Needle decompression using the lateral approach or a longer catheter is more likely to succeed in Asian trauma patients. A high BMI is an independent predictor of failure of NT, especially for the anterior as compared to lateral approach.

  17. discouraged by queue length

    Directory of Open Access Journals (Sweden)

    P. R. Parthasarathy

    2001-01-01

    Full Text Available The transient solution is obtained analytically using continued fractions for a state-dependent birth-death queue in which potential customers are discouraged by the queue length. This queueing system is then compared with the well-known infinite server queueing system which has the same steady state solution as the model under consideration, whereas their transient solutions are different. A natural measure of speed of convergence of the mean number in the system to its stationarity is also computed.

  18. Calculation of exit dose for conformal and dynamically‐wedged fields, based on water‐equivalent path length measured with an amorphous silicon electronic portal imaging device

    Science.gov (United States)

    Glegg, Martin; Metwaly, Mohamed; Currie, Garry; Elliott, Alex

    2011-01-01

    In this study, we use the quadratic calibration method (QCM), in which an EPID image is converted into a matrix of equivalent path lengths (EPLs) and, therefore, exit doses, so as to model doses in conformal and enhanced dynamic wedge (EDW) fields. The QCM involves acquiring series of EPID images at a reference field size for different thicknesses of homogeneous solid water blocks. From these, a set of coefficients is established that is used to compute the EPL of any other irradiated material. To determine the EPL, the irradiated area must be known in order to establish the appropriate scatter correction. A method was devised for the automatic calculation of areas from the EPID image that facilitated the calculation of EPL for any field and exit dose. For EDW fields, the fitting coefficients were modified by utilizing the linac manufacturer's golden segmented treatment tables (GSTT) methodology and MU fraction model. The nonlinear response of the EPL with lower monitor units (MUs) was investigated and slight modification of the algorithm performed to account for this. The method permits 2D dose distributions at the exit of phantom or patient to be generated by relating the EPL with an appropriate depth dose table. The results indicate that the inclusion of MU correction improved the EPL determination. The irradiated field areas can be accurately determined from EPID images to within ± 1% uncertainty. Cross‐plane profiles and 2D dose distributions of EPID predicted doses were compared with those calculated with the Eclipse treatment planning system (TPS) and those measured directly with MapCHECK 2 device. Comparison of the 2D EPID dose maps to those from TPS and MapCHECK shows that more than 90% of all points passed the gamma index acceptance criteria of 3% dose difference and 3 mm distance to agreement (DTA), for both conformal and EDW study cases. We conclude that the EPID QCM is an accurate and convenient method for in vivo dosimetry and may, therefore

  19. Measurement of absolute light yield and determination of a lower limit for the light attenuation length for YAP:Ce crystal

    International Nuclear Information System (INIS)

    Del Guerra, A.; Domenico, G.D.; Zavattini, G.

    1996-01-01

    The aim of this work was to study the peak position of the photoabsorption peak as a function of the interaction distance from the photomultiplier window in order to get some information about the light attenuation length, internal reflectivity and absolute light yield for a 2 x 2 x 30 mm 3 YAP:Ce scintillator

  20. Comparison of Birth-and Conception-Based Definitions of Postnatal Age in Developmental and Reproductive Rodent Toxicity Studies: lnfluence of Gestation Length on Measurements of Offspring Body Weight and Puberty in Controls

    Science.gov (United States)

    Most laboratories conducting developmental and reproductive toxicity studies in rodents assign age by defining postnatal day (PND) 0 or 1 as the day of birth (DOB); i.e., gestation length affects PND and the timing of postnatal measurements. Some laboratories, however, define age...

  1. First-trimester screening in pregnancies conceived by assisted reproductive technology: significance of gestational dating by oocyte retrieval or sonographic measurement of crown-rump length

    DEFF Research Database (Denmark)

    Gjerris, A.C.; Loft, A.; Pinborg, A.

    2008-01-01

    OBJECTIVES: To evaluate, in pregnancies conceived by assisted reproductive technology, whether determination of gestational age (GA) by date of oocyte aspiration (DOA) or crown-rump length (CRL) at first-trimester screening influences the distribution of serum and sonographic markers or the perfo......OBJECTIVES: To evaluate, in pregnancies conceived by assisted reproductive technology, whether determination of gestational age (GA) by date of oocyte aspiration (DOA) or crown-rump length (CRL) at first-trimester screening influences the distribution of serum and sonographic markers......). Weight-corrected log multiples of the median (MoM) marker distributions specific for IVF pregnancy were established using multiple log regression and compared for DOA- and CRL-based GA calculation. RESULTS: GA determined by CRL was significantly larger, albeit slightly, than was GA determined by DOA...

  2. Mature clustered, regularly interspaced, short palindromic repeats RNA (crRNA) length is measured by a ruler mechanism anchored at the precursor processing site.

    Science.gov (United States)

    Hatoum-Aslan, Asma; Maniv, Inbal; Marraffini, Luciano A

    2011-12-27

    Precise RNA processing is fundamental to all small RNA-mediated interference pathways. In prokaryotes, clustered, regularly interspaced, short palindromic repeats (CRISPR) loci encode small CRISPR RNAs (crRNAs) that protect against invasive genetic elements by antisense targeting. CRISPR loci are transcribed as a long precursor that is cleaved within repeat sequences by CRISPR-associated (Cas) proteins. In many organisms, this primary processing generates crRNA intermediates that are subject to additional nucleolytic trimming to render mature crRNAs of specific lengths. The molecular mechanisms underlying this maturation event remain poorly understood. Here, we defined the genetic requirements for crRNA primary processing and maturation in Staphylococcus epidermidis. We show that changes in the position of the primary processing site result in extended or diminished maturation to generate mature crRNAs of constant length. These results indicate that crRNA maturation occurs by a ruler mechanism anchored at the primary processing site. We also show that maturation is mediated by specific cas genes distinct from those genes involved in primary processing, showing that this event is directed by CRISPR/Cas loci.

  3. The effects of surgical lengthening of hamstring muscles in children with cerebral palsy--the consequences of pre-operative muscle length measurement.

    Science.gov (United States)

    Laracca, Ettore; Stewart, Caroline; Postans, Neil; Roberts, Andrew

    2014-03-01

    Children with cerebral palsy often undergo multiple orthopaedic surgical procedures in a single episode. Evidence of the effectiveness of individual components within the overall package is sparse. The introduction of musculoskeletal modelling in Oswestry has led to a more conservative management approach being taken with hamstring muscles for children walking in a degree of crouch. Muscles which were shown to be of at least normal length at initial contact were not surgically lengthened, as would have been the case previously. A retrospective review of 30 such patients was therefore possible, comparing 15 patients treated before the policy change who had their hamstrings lengthened with 15 treated after who did not. All patients had pre and post operative gait assessments and significant changes were observed for each group separately and for the two groups when compared. The comparison revealed that preserving the hamstrings does tend to reduce, and therefore normalize, the dynamic muscle length. Examination of the two patient groups separately, however, reveals a more complex picture with more global gait improvements seen when the hamstrings were lengthened. No absolute recommendation can be made to inform the clinical management of all children with normal to long hamstring muscles during gait. The final decision of whether to include a hamstring lengthening will need to take into account the characteristics of the individual child. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Endodontic Working Length Measurement Using Cone-beam Computed Tomographic Images Obtained at Different Voxel Sizes and Field of Views, Periapical Radiography, and Apex Locator: A Comparative Ex Vivo Study.

    Science.gov (United States)

    Yılmaz, Funda; Kamburoğlu, Kıvanç; Şenel, Buğra

    2017-01-01

    The aim of this study was to evaluate the accuracy of working length determination by using an electronic apex locator, periapical radiography, and cone-beam computed tomographic (CBCT) imaging obtained at different voxel sizes and field of views (FOVs) in extracted human teeth. Thirty extracted human mandibular premolar teeth were used. The electronic working length measurements were performed by using an electronic apex locator (Root ZX; J Morita Corp, Kyoto, Japan). Five different image sets were obtained as follows: (1) CBCT imaging: 40 × 40 mm FOV, 0.080 mm 3 (FOV 40 ); (2) CBCT imaging: 60 × 60 mm FOV, 0.125 mm 3 (FOV 60 ); (3) CBCT imaging: 80 × 80 mm FOV, 0.160 mm 3 (FOV 80 ); (4) CBCT imaging: 100 × 100 mm FOV, 0.250 mm 3 (FOV 100 ); and (5) periapical digital radiography. Direct measurements performed with an electronic digital caliper were considered as the gold standard and compared with the electronic apex locator, CBCT, and periapical image measurements. Data were analyzed using a 2-way analysis of variance test. Significance level was set at P  .05 and the Gage R&R value was 30%). There were significant differences in the methods in terms of mean differences from the gold standard (P < .05). This study showed that available CBCT scans with different FOVs can be used for working length measurement. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  5. Direct measuring of single-cycle mid-IR light bullets path length in LiF by the laser coloration method

    Science.gov (United States)

    Chekalin, Sergey; Kompanets, Victor; Kuznetsov, Andrey; Dormidonov, Alexander; Kandidov, Valerii

    2017-10-01

    A colour-centre structure formed in a LiF crystal under filamentation of a femtosecond mid-IR laser pulse with a power slightly exceeding the critical power for self-focusing has been experimentally and theoretically investigated. A single-cycle light bullet was recorded for the first time by observation of strictly periodic oscillations for the density of the color centers induced in an isotropic LiF crystal under filamentation of a laser beam with a wavelength tuned in the range from 2600 to 3900 nm, which is due to the periodic change in the light field amplitude in the light bullet formed under filamentation under propagation in dispersive medium. The light bullet path length was not more than one millimeter.

  6. Direct measuring of single-cycle mid-IR light bullets path length in LiF by the laser coloration method

    Directory of Open Access Journals (Sweden)

    Chekalin Sergey

    2017-01-01

    Full Text Available A colour-centre structure formed in a LiF crystal under filamentation of a femtosecond mid-IR laser pulse with a power slightly exceeding the critical power for self-focusing has been experimentally and theoretically investigated. A single-cycle light bullet was recorded for the first time by observation of strictly periodic oscillations for the density of the color centers induced in an isotropic LiF crystal under filamentation of a laser beam with a wavelength tuned in the range from 2600 to 3900 nm, which is due to the periodic change in the light field amplitude in the light bullet formed under filamentation under propagation in dispersive medium. The light bullet path length was not more than one millimeter.

  7. Telomere length analysis.

    Science.gov (United States)

    Canela, Andrés; Klatt, Peter; Blasco, María A

    2007-01-01

    Most somatic cells of long-lived species undergo telomere shortening throughout life. Critically short telomeres trigger loss of cell viability in tissues, which has been related to alteration of tissue function and loss of regenerative capabilities in aging and aging-related diseases. Hence, telomere length is an important biomarker for aging and can be used in the prognosis of aging diseases. These facts highlight the importance of developing methods for telomere length determination that can be employed to evaluate telomere length during the human aging process. Telomere length quantification methods have improved greatly in accuracy and sensitivity since the development of the conventional telomeric Southern blot. Here, we describe the different methodologies recently developed for telomere length quantification, as well as their potential applications for human aging studies.

  8. Validity of hamstring muscle length assessment during the sit-and-reach test using an inclinometer to measure hip joint angle.

    Science.gov (United States)

    Youdas, James W; Krause, David A; Hollman, John H

    2008-01-01

    The aim of this study was twofold: (i) to describe the criterion-related validity of the sit-and-reach test (SRT) using a hand-held inclinometer when assessing hamstring muscle length (HML) when HML is recorded in degrees of hip joint angle (HJA); and (ii) to describe the effect of gender and age on HML in healthy adults during the performance of a SRT. We examined 212 healthy subjects (106 men and 106 women) whose ages ranged from 20 to 79 years. The Pearson-product moment correlation coefficient (r) described the relationship between HJA at the end-point of the SRT and the criterion, supine passive straight-leg raise (PSLR). We conducted a 6 x 2 analysis of variance, where age was stratified on 6 levels of 10-year increments (20-29, 30-39, 40-49, 50-59, 60-69, and 70-79 years of age) and gender was stratified on 2 levels (men and women). There was a statistically significant correlation (r = 0.59, P sitting position on a hard surface. Clinicians should recognize there are differences in HML between men and women, and that men and women between 20 to 49 years of age have more HML than their counterparts between ages 60 to 79 years.

  9. Fractional baud-length coding

    Directory of Open Access Journals (Sweden)

    J. Vierinen

    2011-06-01

    Full Text Available We present a novel approach for modulating radar transmissions in order to improve target range and Doppler estimation accuracy. This is achieved by using non-uniform baud lengths. With this method it is possible to increase sub-baud range-resolution of phase coded radar measurements while maintaining a narrow transmission bandwidth. We first derive target backscatter amplitude estimation error covariance matrix for arbitrary targets when estimating backscatter in amplitude domain. We define target optimality and discuss different search strategies that can be used to find well performing transmission envelopes. We give several simulated examples of the method showing that fractional baud-length coding results in smaller estimation errors than conventional uniform baud length transmission codes when estimating the target backscatter amplitude at sub-baud range resolution. We also demonstrate the method in practice by analyzing the range resolved power of a low-altitude meteor trail echo that was measured using a fractional baud-length experiment with the EISCAT UHF system.

  10. Myofilament length dependent activation

    Energy Technology Data Exchange (ETDEWEB)

    de Tombe, Pieter P.; Mateja, Ryan D.; Tachampa, Kittipong; Mou, Younss Ait; Farman, Gerrie P.; Irving, Thomas C. (IIT); (Loyola)

    2010-05-25

    The Frank-Starling law of the heart describes the interrelationship between end-diastolic volume and cardiac ejection volume, a regulatory system that operates on a beat-to-beat basis. The main cellular mechanism that underlies this phenomenon is an increase in the responsiveness of cardiac myofilaments to activating Ca{sup 2+} ions at a longer sarcomere length, commonly referred to as myofilament length-dependent activation. This review focuses on what molecular mechanisms may underlie myofilament length dependency. Specifically, the roles of inter-filament spacing, thick and thin filament based regulation, as well as sarcomeric regulatory proteins are discussed. Although the 'Frank-Starling law of the heart' constitutes a fundamental cardiac property that has been appreciated for well over a century, it is still not known in muscle how the contractile apparatus transduces the information concerning sarcomere length to modulate ventricular pressure development.

  11. Upper Extremity Length Equalization

    OpenAIRE

    DeCoster, Thomas A.; Ritterbusch, John; Crawford, Mark

    1992-01-01

    Significant upper extremity length inequality is uncommon but can cause major functional problems. The ability to position and use the hand may be impaired by shortness of any of the long bones of the upper extremity. In many respects upper and lower extremity length problems are similar. They most commonly occur after injury to a growing bone and the treatment modalities utilized in the lower extremity may be applied to the upper extremity. These treatment options include epiphysiodesis, sho...

  12. Analysis of ureteral length in adult cadavers

    Directory of Open Access Journals (Sweden)

    Hugo F. F. Novaes

    2013-04-01

    Full Text Available Introduction In some occasions, correlations between human structures can help planning surgical intra-abdominal interventions. The previous determination of ureteral length helps pre-operatory planning of surgeries, reduces costs of auxiliary exams, the correct choice of double-J catheter with low morbidity and fewer symptoms, and an adequate adhesion to treatment. Objective To evaluate ureteral length in adult cadavers and to analyze its correlation with anthropometric measures. Materials and Methods: From April 2009 to January 2012 we determined ureteral length of adult cadavers submitted to necropsy and obtained the following measures: height, distance from shoulder to wrist, elbow-wrist, xiphoid appendix-umbilicus, umbilicus-pubis, xiphoid appendix-pubis and between iliac spines. We analyzed the correlations between ureteral length and those anthropometric measures. Results We dissected 115 ureters from 115 adult corpses from April 2009 to January 2012. Median ureteral length didn't vary between sexes or according to height. It was observed no correlation among ureteral length and all considered anthropometric measures in all analyzed subgroups and in general population. There were no significant differences between right and left ureteral measures. Conclusions There is no difference of ureteral length in relation to height or gender (male or female. There is no significant correlation among ureteral length and the considered anthropometric measures.

  13. Relativistic Length Agony Continued

    Science.gov (United States)

    Redzic, D. V.

    2014-06-01

    We made an attempt to remedy recent confusing treatments of some basic relativistic concepts and results. Following the argument presented in an earlier paper (Redzic 2008b), we discussed the misconceptions that are recurrent points in the literature devoted to teaching relativity such as: there is no change in the object in Special Relativity, illusory character of relativistic length contraction, stresses and strains induced by Lorentz contraction, and related issues. We gave several examples of the traps of everyday language that lurk in Special Relativity. To remove a possible conceptual and terminological muddle, we made a distinction between the relativistic length reduction and relativistic FitzGerald-Lorentz contraction, corresponding to a passive and an active aspect of length contraction, respectively; we pointed out that both aspects have fundamental dynamical contents. As an illustration of our considerations, we discussed briefly the Dewan-Beran-Bell spaceship paradox and the 'pole in a barn' paradox.

  14. Telomere Length and Mortality

    DEFF Research Database (Denmark)

    Kimura, Masayuki; Hjelmborg, Jacob V B; Gardner, Jeffrey P

    2008-01-01

    Leukocyte telomere length, representing the mean length of all telomeres in leukocytes, is ostensibly a bioindicator of human aging. The authors hypothesized that shorter telomeres might forecast imminent mortality in elderly people better than leukocyte telomere length. They performed mortality...... telomeres predicted the death of the first co-twin better than the mTRFL did (mTRFL: 0.56, 95% confidence interval (CI): 0.49, 0.63; mTRFL(50): 0.59, 95% CI: 0.52, 0.66; mTRFL(25): 0.59, 95% CI: 0.52, 0.66; MTRFL: 0.60, 95% CI: 0.53, 0.67). The telomere-mortality association was stronger in years 3-4 than...

  15. 7 CFR 29.6024 - Length.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Length. 29.6024 Section 29.6024 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Standards Definitions § 29.6024 Length. The linear measurement of cured tobacco leaves from the...

  16. Evolução do comprimento cervical uterino na gestação, avaliado pela ultra-sonografia transvaginal Changes in cervical length during pregnancy measured by transvaginal ultrasound

    Directory of Open Access Journals (Sweden)

    Reginaldo Antônio de Oliveira Freitas-Júnior

    2003-03-01

    Full Text Available OBJETIVO: analisar a evolução do comprimento cervical uterino, ao longo da gestação, avaliado por meio da ultra-sonografia transvaginal. MÉTODOS: foi realizado estudo prospectivo, longitudinal, no qual 82 gestantes hígidas foram acompanhadas desde o início da gestação, das quais 49 mantiveram o seguimento até o parto sem complicações da gravidez, sendo examinadas a cada quatro semanas, e agrupadas, conforme a paridade, em nulíparas ou com um ou mais partos anteriores. O comprimento do colo uterino foi avaliado em vista sagital pela ultra-sonografia transvaginal, com a medida linear da distância entre os orifícios cervicais interno e externo. RESULTADOS: as médias de comprimento do colo uterino, bem como os percentis 5, 25, 50, 75 e 95, em função da idade gestacional, não diferiram significativamente entre os grupos estudados (p>0.05. No intervalo entre a 20ª e a 24ª semana gestacional o comprimento cervical variou entre 28, 35 e 47,2 mm, com os percentis 5, 50 e 95, respectivamente. O comprimento cervical uterino diminuiu progressivamente ao longo da gestação normal, sendo esse encurtamento significativo após a 20ª semana de gravidez e mais expressivo após a 28ª semana (pPURPOSE: to establish a normality curve of cervical length during pregnancy measured by transvaginal ultrasonography. METHODS: we conducted a prospective, longitudinal study on 82 healthy pregnant women who were followed up from the beginning of pregnancy to delivery at four-week intervals, of whom 49 concluded the study. Patients were divided according to parity into nulliparous women and women with one or more previous deliveries. Cervical length was measured in a sagittal view by transvaginal ultrasonography, as the linear distance between internal and external cervical os. RESULTS: no significant difference was observed in mean cervical length or the 5th, 25, 50th, 75th, or 95th percentile according to gestational age between groups (p>0

  17. Full Length Research Article

    African Journals Online (AJOL)

    Administrator

    Out of the 320 male sheep examined, 87(27.2%) were infected, while 9(19.1%) of the 47 females examined were infected (Table 2). Infection varied from one abattoir to another. Age related distribution of P. cervi is shown in Table 3. Out of 356 adult sheep (>2yrs) examined, 35. Full Length Research Article. 12 ...

  18. Diagnóstico do parto pré-termo pela medida ultrassonográfica do comprimento do colo uterino Preterm labor diagnosis by sonographic measurement of the uterine cervical length

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Ferreira Novaes

    2009-10-01

    Full Text Available OBJETIVO: Medir o comprimento do colo uterino, utilizando a ultrassonografia transvaginal, em pacientes com quadro clínico compatível com ameaça de parto pré-termo, e correlacionar a medida do colo uterino, em cada caso, com a interrupção espontânea da gravidez dentro de sete dias. MATERIAIS E MÉTODOS: Foram realizados exames ultrassonográficos em 72 pacientes com quadro clínico compatível com ameaça de parto pré-termo. RESULTADOS: A sensibilidade do exame foi de 90,5%, a especificidade, de 98%, o valor preditivo positivo, de 95%, e o valor preditivo negativo, de 96%. A análise foi realizada utilizando-se a medida de 15 mm de comprimento do colo uterino como valor preditivo do parto pré-termo. CONCLUSÃO: Parece ser possível prever o parto pré-termo em pacientes com colo uterino menor que 15 mm. Tal observação poderá trazer contribuição para a administração mais oportuna de corticoides, com o intuito de acelerar a maturidade pulmonar fetal.OBJECTIVE: To measure the uterine cervical length by using transvaginal ultrasonography in patients with clinical signs compatible with preterm labor threat, and correlating each individual measurement with spontaneous pregnancy interruption within seven days. MATERIALS AND METHODS: Sonographic examinations were performed in 72 patients with clinical signs compatible with preterm labor threat. RESULTS: Sensitivity was 90.5%, specificity, 98%, positive predictive value, 95%, and negative predictive value, 96%. A standard uterine cervix length of 15 mm was considered as a predictive value for preterm labor. CONCLUSION: It seems to be possible to foresee preterm delivery in patients whose cervical length is < 15 mm. Such observation could contribute to a timely corticosteroid administration to accelerate fetal lung maturity.

  19. Sorghum cobalt analysis on not determined wave length with atomic ...

    African Journals Online (AJOL)

    This study was to know the better wave length on measuring cobalt content in forage sorghum hybrid (Sorghum bicolor) with an atomic absorption spectrophotometer. The analysis was on background correction mode with three wave lengths; 240.8, 240.7 (determined wave length or recommended wave length) and 240.6 ...

  20. Absolute and relative-rate measurement of the rate coefficient for reaction of perfluoro ethyl vinyl ether (C2F5OCF[double bond, length as m-dash]CF2) with OH.

    Science.gov (United States)

    Srinivasulu, G; Bunkan, A J C; Amedro, D; Crowley, J N

    2018-01-31

    The rate coefficient (k 1 ) for the reaction of OH radicals with perfluoro ethyl vinyl ether (PEVE, C 2 F 5 OCF[double bond, length as m-dash]CF 2 ) has been measured as a function of temperature (T = 207-300 K) using the technique of pulsed laser photolysis with detection of OH by laser-induced fluorescence (PLP-LIF) at pressures of 50 or 100 Torr N 2 bath gas. In addition, the rate coefficient was measured at 298 K and in one atmosphere of air by the relative-rate technique with loss of PEVE and reference reactant monitored in situ by IR absorption spectroscopy. The rate coefficient has a negative temperature dependence which can be parameterized as: k 1 (T) = 6.0 × 10 -13  exp[(480 ± 38/T)] cm 3 molecule -1 s -1 and a room temperature value of k 1 (298 K) = (3.0 ± 0.3) × 10 -12 cm 3 molecule -1 s -1 . Highly accurate rate coefficients from the PLP-LIF experiments were achieved by optical on-line measurements of PEVE and by performing the measurements at two different apparatuses. The large rate coefficient and the temperature dependence indicate that the reaction proceeds via OH addition to the C[double bond, length as m-dash]C double bond, the high pressure limit already being reached at 50 Torr N 2 . Based on the rate coefficient and average OH levels, the atmospheric lifetime of PEVE was estimated to be a few days.

  1. Validity and repeatability of inertial measurement units for measuring gait parameters.

    Science.gov (United States)

    Washabaugh, Edward P; Kalyanaraman, Tarun; Adamczyk, Peter G; Claflin, Edward S; Krishnan, Chandramouli

    2017-06-01

    Inertial measurement units (IMUs) are small wearable sensors that have tremendous potential to be applied to clinical gait analysis. They allow objective evaluation of gait and movement disorders outside the clinic and research laboratory, and permit evaluation on large numbers of steps. However, repeatability and validity data of these systems are sparse for gait metrics. The purpose of this study was to determine the validity and between-day repeatability of spatiotemporal metrics (gait speed, stance percent, swing percent, gait cycle time, stride length, cadence, and step duration) as measured with the APDM Opal IMUs and Mobility Lab system. We collected data on 39 healthy subjects. Subjects were tested over two days while walking on a standard treadmill, split-belt treadmill, or overground, with IMUs placed in two locations: both feet and both ankles. The spatiotemporal measurements taken with the IMU system were validated against data from an instrumented treadmill, or using standard clinical procedures. Repeatability and minimally detectable change (MDC) of the system was calculated between days. IMUs displayed high to moderate validity when measuring most of the gait metrics tested. Additionally, these measurements appear to be repeatable when used on the treadmill and overground. The foot configuration of the IMUs appeared to better measure gait parameters; however, both the foot and ankle configurations demonstrated good repeatability. In conclusion, the IMU system in this study appears to be both accurate and repeatable for measuring spatiotemporal gait parameters in healthy young adults. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Gap length distributions by PEPR

    International Nuclear Information System (INIS)

    Warszawer, T.N.

    1980-01-01

    Conditions guaranteeing exponential gap length distributions are formulated and discussed. Exponential gap length distributions of bubble chamber tracks first obtained on a CRT device are presented. Distributions of resulting average gap lengths and their velocity dependence are discussed. (orig.)

  3. Length of excitable knots

    Science.gov (United States)

    Maucher, Fabian; Sutcliffe, Paul

    2017-07-01

    In this paper, we present extensive numerical simulations of an excitable medium to study the long-term dynamics of knotted vortex strings for all torus knots up to crossing number 11. We demonstrate that FitzHugh-Nagumo evolution preserves the knot topology for all the examples presented, thereby providing a field theory approach to the study of knots. Furthermore, the evolution yields a well-defined minimal length for each knot that is comparable to the ropelength of ideal knots. We highlight the role of the medium boundary in stabilizing the length of the knot and discuss the implications beyond torus knots. We also show that there is not a unique attractor within a given knot topology.

  4. Pion nucleus scattering lengths

    International Nuclear Information System (INIS)

    Huang, W.T.; Levinson, C.A.; Banerjee, M.K.

    1971-09-01

    Soft pion theory and the Fubini-Furlan mass dispersion relations have been used to analyze the pion nucleon scattering lengths and obtain a value for the sigma commutator term. With this value and using the same principles, scattering lengths have been predicted for nuclei with mass number ranging from 6 to 23. Agreement with experiment is very good. For those who believe in the Gell-Mann-Levy sigma model, the evaluation of the commutator yields the value 0.26(m/sub σ//m/sub π/) 2 for the sigma nucleon coupling constant. The large dispersive corrections for the isosymmetric case implies that the basic idea behind many of the soft pion calculations, namely, slow variation of matrix elements from the soft pion limit to the physical pion mass, is not correct. 11 refs., 1 fig., 3 tabs

  5. Length-weight and length-length relationships of freshwater wild ...

    African Journals Online (AJOL)

    Length-weight and length-length relationships of freshwater wild catfish Mystus bleekeri from Nala Daik, Sialkot, Pakistan. ... Linear regression analysis was used, first to compute the degree of relationship between length and weight and then among total (TL), standard (SL) and fork lengths (FL). LWR exhibited a highly ...

  6. Relativistic length agony continued

    Directory of Open Access Journals (Sweden)

    Redžić D.V.

    2014-01-01

    Full Text Available We made an attempt to remedy recent confusing treatments of some basic relativistic concepts and results. Following the argument presented in an earlier paper (Redžić 2008b, we discussed the misconceptions that are recurrent points in the literature devoted to teaching relativity such as: there is no change in the object in Special Relativity, illusory character of relativistic length contraction, stresses and strains induced by Lorentz contraction, and related issues. We gave several examples of the traps of everyday language that lurk in Special Relativity. To remove a possible conceptual and terminological muddle, we made a distinction between the relativistic length reduction and relativistic FitzGerald-Lorentz contraction, corresponding to a passive and an active aspect of length contraction, respectively; we pointed out that both aspects have fundamental dynamical contents. As an illustration of our considerations, we discussed briefly the Dewan-Beran-Bell spaceship paradox and the ‘pole in a barn’ paradox. [Projekat Ministarstva nauke Republike Srbije, br. 171028

  7. Socio-demographic psychosocial and clinical characteristics of participants in e-HealthyStrides©: an interactive ehealth program to improve diabetes self-management skills.

    Science.gov (United States)

    Pemu, Priscilla E; Quarshie, Alexander Q; Josiah-Willock, R; Ojutalayo, Folake O; Alema-Mensah, Ernest; Ofili, Elizabeth O

    2011-01-01

    Diabetes self-management (DSM) training helps prevent diabetic complications. eHealth approaches may improve its optimal use. The aims were to determine a) acceptability of e-HealthyStrides© (an interactive, Internet-based, patient-driven, diabetes self-management support and social networking program) among Morehouse Community Physicians' Network diabetics; b) efficacy for DSM behavior change c) success factors for use of e-HealthyStrides©. Baseline characteristics of pilot study participants are reported. Of those approached, 13.8% agreed to participate. Among participants, 96% were Black, 77% female; age 56±9.2 years; education: 44% college or higher and 15% less than 12th grade; 92.5% with home computers. Over half (51%) failed the Diabetes Knowledge Test. Nearly half (47%) were at goal A1C; 24% at goal blood pressure; 3% at goal LDL cholesterol level. Median (SD) Diabetes Empowerment Scale score = 3.93 (0.72) but managing psychosocial aspects = 3.89 (0.89) scored lower than other domains. There was low overall confidence for DSM behaviors. Assistance with healthy eating was the most frequently requested service. Requestors were more obese with worse A1C than others. Chronic care delivery scored average with high scores for counseling and problem solving but low scores for care coordination and follow up.

  8. Improvement in Body Image, Perceived Health, and Health-Related Self-Efficacy Among People With Serious Mental Illness: The STRIDE Study.

    Science.gov (United States)

    Yarborough, Bobbi Jo H; Leo, Michael C; Yarborough, Micah T; Stumbo, Scott; Janoff, Shannon L; Perrin, Nancy A; Green, Carla A

    2016-03-01

    The authors examined secondary outcomes of STRIDE, a randomized controlled trial that tested a weight-loss and lifestyle intervention for individuals taking antipsychotic medications. Hierarchical linear regression was used to explore the effects of the intervention and weight change at follow-up (six, 12, and 24 months) on body image, perceived health, and health-related self-efficacy. Participants were 200 adults who were overweight and taking antipsychotic agents. Weight change × study arm interaction was associated with significant improvement in body image from baseline to six months. From baseline to 12 months, body image scores of intervention participants improved by 1.7 points more compared with scores of control participants; greater weight loss was associated with more improvement. Between baseline and 24 months, greater weight loss was associated with improvements in body image, perceived health, and health-related self-efficacy. Participation in STRIDE improved body image, and losing weight improved perceived health and health-related self-efficacy.

  9. The length of the male urethra

    Directory of Open Access Journals (Sweden)

    Tobias. S. Kohler

    2008-08-01

    Full Text Available PURPOSE: Catheter-based medical devices are an important component of the urologic armamentarium. To our knowledge, there is no population-based data regarding normal male urethral length. We evaluated the length of the urethra in men with normal genitourinary anatomy undergoing either Foley catheter removal or standard cystoscopy. MATERIALS AND METHODS: Male urethral length was obtained in 109 men. After study permission was obtained, the subject's penis was placed on a gentle stretch and the catheter was marked at the tip of the penis. The catheter was then removed and the distance from the mark to the beginning of the re-inflated balloon was measured. Alternatively, urethral length was measured at the time of cystoscopy, on removal of the cystoscope. Data on age, weight, and height was obtained in patients when possible. RESULTS: The mean urethral length was 22.3 cm with a standard deviation of 2.4 cm. Urethral length varied between 15 cm and 29 cm. No statistically significant correlation was found between urethral length and height, weight, body mass index (BMI, or age. CONCLUSIONS: Literature documenting the length of the normal male adult urethra is scarce. Our data adds to basic anatomic information of the male urethra and may be used to optimize genitourinary device design.

  10. Intersubunit distances in full-length, dimeric, bacterial phytochrome Agp1, as measured by pulsed electron-electron double resonance (PELDOR) between different spin label positions, remain unchanged upon photoconversion.

    Science.gov (United States)

    Kacprzak, Sylwia; Njimona, Ibrahim; Renz, Anja; Feng, Juan; Reijerse, Edward; Lubitz, Wolfgang; Krauss, Norbert; Scheerer, Patrick; Nagano, Soshichiro; Lamparter, Tilman; Weber, Stefan

    2017-05-05

    Bacterial phytochromes are dimeric light-regulated histidine kinases that convert red light into signaling events. Light absorption by the N-terminal photosensory core module (PCM) causes the proteins to switch between two spectrally distinct forms, Pr and Pfr, thus resulting in a conformational change that modulates the C-terminal histidine kinase region. To provide further insights into structural details of photoactivation, we investigated the full-length Agp1 bacteriophytochrome from the soil bacterium Agrobacterium fabrum using a combined spectroscopic and modeling approach. We generated seven mutants suitable for spin labeling to enable application of pulsed EPR techniques. The distances between attached spin labels were measured using pulsed electron-electron double resonance spectroscopy to probe the arrangement of the subunits within the dimer. We found very good agreement of experimental and calculated distances for the histidine-kinase region when both subunits are in a parallel orientation. However, experimental distance distributions surprisingly showed only limited agreement with either parallel- or antiparallel-arranged dimer structures when spin labels were placed into the PCM region. This observation indicates that the arrangements of the PCM subunits in the full-length protein dimer in solution differ significantly from that in the PCM crystals. The pulsed electron-electron double resonance data presented here revealed either no or only minor changes of distance distributions upon Pr-to-Pfr photoconversion. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  11. Short cervical length dilemma.

    Science.gov (United States)

    Suhag, Anju; Berghella, Vincenzo

    2015-06-01

    Preterm birth (PTB) is a leading cause of neonatal morbidity and mortality. With research efforts, the rate of PTB decreased to 11.4% in 2013. Transvaginal ultrasound (TVU) cervical length (CL) screening predicts PTB. In asymptomatic singletons without prior spontaneous PTB (sPTB), TVU CL screening should be done. If the cervix is 20 mm or less, vaginal progesterone is indicated. In asymptomatic singletons with prior sPTB, serial CL screening is indicated. In multiple gestations, routine cervical screening is not indicated. In symptomatic women with preterm labor, TVU CL screening and fetal fibronectin testing is recommended. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Primary length standard adjustment

    Science.gov (United States)

    Ševčík, Robert; Guttenová, Jana

    2007-04-01

    This paper deals with problems and techniques connected with primary length standard adjusting, which includes disassembling of the device and by use of the secondary laser with collimated beam and diffraction laws successively reassembling of the laser. In the reassembling process the device was enhanced with substituting the thermal grease cooling of cold finger by copper socket cooler. This improved external cooling system enables more effective cooling of molecular iodine in the cell, which allows better pressure stability of iodine vapor and easier readjustment of the system.

  13. Inhibition of thermolysin by phosphonamidate transition-state analogues: measurement of 31P-15N bond lengths and chemical shifts in two enzyme-inhibitor complexes by solid-state nuclear magnetic resonance.

    Science.gov (United States)

    Copié, V; Kolbert, A C; Drewry, D H; Bartlett, P A; Oas, T G; Griffin, R G

    1990-10-02

    31P and 15N chemical shifts and 31P-15N bond lengths have been measured with solid-state NMR techniques in two inhibitors of thermolysin, carbobenzoxy-Glyp-L-Leu-L-Ala (ZGpLA) and carbobenzoxy-L-Phep-L-Leu-L-Ala (ZFpLA), both as free lithium salts and when bound to the enzyme. Binding of both inhibitors to thermolysin results in large changes in the 31P chemical shifts. These changes are more dramatic for the tighter binding inhibitor ZFpLA, where a approximately 20 ppm downfield movement of the 31P isotropic chemical shift (sigma iso) is observed. This shift is due to changes in the shift tensor elements sigma 11 and sigma 22, while sigma 33 remains essentially constant. We observed a similar pattern for ZGpLA, but only a approximately 5 ppm change occurs in sigma iso. The changes in the 15N chemical shifts for both inhibitors are small upon binding, amounting to downfield shifts of 2 and 4 ppm for ZGpLA and ZFpLA, respectively. This indicates that there are no changes in the protonation state of the 15N in either the ZFpLA- or the ZGpLA-thermolysin complex. NMR distance measurements yield a P-N bond length rP-N = 1.68 +/- 0.03 A for the tight binding inhibitor ZFpLA both in its free lithium salt form and in its thermolysin-ZFpLA complex, a distance that is much shorter than the 1.90-A distance reported by X-ray crystallography studies [Holden et al. (1987) Biochemistry 26, 8542-8553].(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Economic issues of broiler production length

    Directory of Open Access Journals (Sweden)

    Szőllősi László

    2014-01-01

    Full Text Available The length of broiler production cycle is also an important factor when profitability is measured. This paper is to determine the effects of different market ages and down-time period, overall broiler production cycle length on performance and economic parameters based on Hungarian production and financial circumstances. A deterministic model was constructed to manage the function-like correlations of age-related daily weight gain, daily feed intake and daily mortality data. The results show that broiler production cycle length has a significant effect on production and economic performance. Cycle length is determined by the length of down-time and grow-out periods. If down-time period is reduced by one day, an average net income of EUR 0.55 per m2 is realizable. However, the production period is not directly proportional either with emerging costs or obtainable revenues. Profit maximization is attainable if the production period is 41-42 days.

  15. AGS vertical beta function measurements for Run 15

    Energy Technology Data Exchange (ETDEWEB)

    Harper, C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ahrens, L. [Brookhaven National Lab. (BNL), Upton, NY (United States); Huang, H. [Brookhaven National Lab. (BNL), Upton, NY (United States); Schoefer, V. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-10-07

    One key parameter for running the AGS efficiently is by maintaining a low emittance. To measure emittance, one needs to measure the beta function throughout the cycle. This can be done by measuring the beta function at the ionization profile monitors (IPM) in the AGS. This tech note delves into the motivation, the measurement, and some strides that were made throughout Run15.

  16. Método para medida do comprimento da cóclea por meio de ressonância magnética A method for measuring the length of the coclea through magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Fernando Pochini Sobrinho

    2009-04-01

    Full Text Available Sabe-se que a deficiência auditiva afeta boa parte da população. Nos casos em que a surdez é profunda e bilateral, podem ocorrer problemas na aquisição de fala nas crianças, bem como na comunicação e socialização do indivíduo. O implante coclear vem sendo utilizado como opção terapêutica para esses casos. Na atualidade a Ressonância magnética da orelha interna é exame obrigatório na avaliação pré-operatória destes pacientes. No dia-a-dia, nos perguntamos se a ressonância magnética pode fornecer dados não só qualitativos como também quantitativos, com medidas lineares reais na cóclea reconstruída em imagens em três dimensões. OBJETIVO: O objetivo deste estudo é propor uma técnica para obtenção de medidas do comprimento da cóclea em imagens de ressonância magnética obtidos de ossos temporais de cadáveres. MATERIAL E MÉTODO: Foram avaliadas imagens de reconstrução em três dimensões da cóclea de seis cadáveres. Por meio de sobreposição de réguas digitalizadas sobre estas imagens foi possível medir o comprimento coclear. RESULTADO: Estas medidas variaram de 17 a 26,5 milímetros. CONCLUSÃO: Conclui-se que foi possível medir o comprimento da cóclea em imagens em três dimensões de ressonância magnética pelo método proposto.We know that hearing impairment affects a large part of the population. In cases of profound and bilateral hearing loss, children may have problems in speech development, as well as communication and socialization. Cochlear implants have been used as a treatment option in these cases. Today, inner ear MRI is a mandatory test in the preoperative evaluation of these individuals. In our daily routines, we wonder whether MRI can provide not only qualitative, but also quantitative data, with real cochlear linear values built from three dimension images. AIMS: The aim of the present investigation is to propose a method to obtain MRI cochlear length measures from the temporal bones

  17. Kidney Length in Normal Korean Children

    International Nuclear Information System (INIS)

    Kim, In One; Cheon, Jung Eun; Lee, Young Seok; Lee, Sun Wha; Kim, Ok Hwa; Kim, Ji Hye; Kim, Hong Dae; Sim, Jung Suk

    2010-01-01

    Renal length offers important information to detect or follow-up various renal diseases. The purpose of this study was to determine the kidney length of normal Korean children in relation to age, height, weight, body surface area (BSA), and body mass index (BMI). Children between 1 month and 15 years of age without urological abnormality were recruited. Children below 3rd percentile and over 97th percentile for height or weight were excluded. Both renal lengths were measured in the prone position three times and then averaged by experienced radiologists. The mean length and standard deviation for each age group was obtained, and regression equation was calculated between renal length and age, weight, height, BSA, and BMI, respectively. Renal length was measured in 550 children. Renal length grows rapidly until 24 month, while the growth rate is reduced thereafter. The regression equation for age is: renal length (mm) = 45.953 + 1.064 x age (month, ≤ 24 months) (R2 = 0.720) or 62.173 + 0.203 x age (months, > 24 months) (R2 = 0.711). The regression equation for height is: renal length (mm) = 24.494 + 0.457 x height (cm) (R2 = 0.894). The regression equation for weight is: renal length (mm) = 38.342 + 2.117 x weight (kg, ≤18 kg) (R2 = 0.852) or 64.498 + 0.646 x weight (kg, > 18 kg) (R2 = 0.651). The regression equation for BSA is: renal length (mm) = 31.622 + 61.363 x BSA (m2, ≤ 0.7) (R2 = 0.857) or 52.717 + 29.959 x BSA (m2, > 0.7) (R2 = 0.715). The regression equation for BMI is: renal length (mm) = 44.474 + 1.163 x BMI (R2 = 0.079). This study provides data on the normal renal length and its association with age, weight, height, BSA and BMI. The results of this study will guide the detection and follow-up of renal diseases in Korean children

  18. The comparison between the length of vertical dimension of occlusion and the length of thumb on undergraduate Mongoloid students

    Directory of Open Access Journals (Sweden)

    Goh Li Teng

    2011-03-01

    Full Text Available The Thumb Rule of Leonardo da Vinci states that many proportions of the face show relationship with the length of thumb which is measured from the proximal tip of the proximal phalanx to the distal tip of the distal phalanx. Previous studies have shown that the length of the vertical dimension of occlusion (VDO is similar to the length of thumb of the Caucasoid race. The purpose of this study is to determine whether the length of VDO have correlations with the length of thumb among those of the Mongoloid race. This study took a survey method with the analytical cross-sectional approach. A total of 80 students of Faculty of Dentistry who have fulfilled all population criteria were randomly chosen to measure the length of VDO and the length of the thumb. Results analyzed with Student's t-test statistic revealed that there was a significant difference between males and females in the length of VDO and the length of the thumb, however, there was no significant difference between the length of VDO and the length of the thumb. There were very strong correlations (P<0.05 between the length of VDO and the length of the thumb. As a conclusion, the length of thumb can be suggested as an objective method to determine the length of VDO in this population.

  19. Correlation lengths of electrostatic turbulence

    International Nuclear Information System (INIS)

    Guiziou, L.; Garbet, X.

    1995-01-01

    This document deals with correlation length of electrostatic turbulence. First, the model of drift waves turbulence is presented. Then, the radial correlation length is determined analytically with toroidal coupling and non linear coupling. (TEC). 5 refs

  20. Influenza activity in Europe during eight seasons (1999–2007: an evaluation of the indicators used to measure activity and an assessment of the timing, length and course of peak activity (spread across Europe

    Directory of Open Access Journals (Sweden)

    Meijer Adam

    2007-11-01

    Full Text Available Abstract Background The European Influenza Surveillance Scheme (EISS has collected clinical and virological data on influenza since 1996 in an increasing number of countries. The EISS dataset was used to characterise important epidemiological features of influenza activity in Europe during eight winters (1999–2007. The following questions were addressed: 1 are the sentinel clinical reports a good measure of influenza activity? 2 how long is a typical influenza season in Europe? 3 is there a west-east and/or south-north course of peak activity ('spread' of influenza in Europe? Methods Influenza activity was measured by collecting data from sentinel general practitioners (GPs and reports by national reference laboratories. The sentinel reports were first evaluated by comparing them to the laboratory reports and were then used to assess the timing and spread of influenza activity across Europe during eight seasons. Results We found a good match between the clinical sentinel data and laboratory reports of influenza collected by sentinel physicians (overall match of 72% for +/- 1 week difference. We also found a moderate to good match between the clinical sentinel data and laboratory reports of influenza from non-sentinel sources (overall match of 60% for +/- 1 week. There were no statistically significant differences between countries using ILI (influenza-like illness or ARI (acute respiratory disease as case definition. When looking at the peak-weeks of clinical activity, the average length of an influenza season in Europe was 15.6 weeks (median 15 weeks; range 12–19 weeks. Plotting the peak weeks of clinical influenza activity reported by sentinel GPs against the longitude or latitude of each country indicated that there was a west-east spread of peak activity (spread of influenza across Europe in four winters (2001–2002, 2002–2003, 2003–2004 and 2004–2005 and a south-north spread in three winters (2001–2002, 2004–2005 and 2006

  1. Correlation lengths of electrostatic turbulence

    International Nuclear Information System (INIS)

    Guiziou, L.; Garbet, X.

    1995-01-01

    In this paper, the radial correlation length of an electrostatic drift wave turbulence is analytically determined in various regimes. The analysis relies on the calculation of a range of mode non linear interaction, which is an instantaneous correlation length. The link with the usual correlation length has not been investigated yet. (TEC). 5 refs

  2. Random fractal characters and length uncertainty of the continental ...

    Indian Academy of Sciences (India)

    A coastline is a random fractal object in a geographical system whose length is uncertain. To determine the coastline length of a country or a region, the scaling region and fractal dimension of the coastline is first calculated, and then, the length of the coastline is measured using the scale at the lower limit or near the limit of ...

  3. LENGTH-WEIGHT RELATIONSHIP AND CONDITION FACTOR OF ...

    African Journals Online (AJOL)

    Data Collection and Analysis. The measurements of length (cm), weight (g) and the condition factor of individual fish sampled were recorded. The relationship between length and weight of the fish was examined by simple linear regression using WINKS software. The variations in the length-weight represented by 'b' were.

  4. Full Length Research Article

    African Journals Online (AJOL)

    Dr Ahmed

    1School of Science Technology, Federal College of Chemical and Leather. Technology, PMB 1034, Zaria. Nigeria. ... investment for T periods at an interest rate or rate of return of r per annum (Bowers et al., 1986). .... Hence the variance around the mean may be used to measure the degree of confidence about the possible ...

  5. Controlling the optical path length in turbid media using differential path-length spectroscopy: fiber diameter dependence

    NARCIS (Netherlands)

    Kaspers, O. P.; Sterenborg, H. J. C. M.; Amelink, A.

    2008-01-01

    We have characterized the path length for the differential path-length spectroscopy (DPS) fiber optic geometry for a wide range of optical properties and for fiber diameters ranging from 200 mu m to 1000 mu m. Phantom measurements show that the path length is nearly constant for scattering

  6. Length expectation values in quantum Regge calculus

    International Nuclear Information System (INIS)

    Khatsymovsky, V.M.

    2004-01-01

    Regge calculus configuration superspace can be embedded into a more general superspace where the length of any edge is defined ambiguously depending on the 4-tetrahedron containing the edge. Moreover, the latter superspace can be extended further so that even edge lengths in each the 4-tetrahedron are not defined, only area tensors of the 2-faces in it are. We make use of our previous result concerning quantization of the area tensor Regge calculus which gives finite expectation values for areas. Also our result is used showing that quantum measure in the Regge calculus can be uniquely fixed once we know quantum measure on (the space of the functionals on) the superspace of the theory with ambiguously defined edge lengths. We find that in this framework quantization of the usual Regge calculus is defined up to a parameter. The theory may possess nonzero (of the order of Planck scale) or zero length expectation values depending on whether this parameter is larger or smaller than a certain value. Vanishing length expectation values means that the theory is becoming continuous, here dynamically in the originally discrete framework

  7. Lesion length assessment using a new vessel caliper.

    Science.gov (United States)

    Wolyn, Robert; Dixon, Simon R; Almany, Steven L; Korotko, Joe; Huang, Raywin R; O'Neill, William W

    2003-02-01

    Assessment of coronary lesion length using visual estimation or quantitative coronary angiography can be unreliable. We tested the accuracy of a new handheld caliper device to measure lesion length in a bench-top model and in eight patients undergoing percutaneous coronary intervention (PCI). Caliper-derived length measurements were compared to the known reference distance in the bench-top model and visual or intravascular ultrasound (IVUS)-derived measurements in vivo. In the coronary model, caliper-derived measurements were accurate and correlated well with known reference distances regardless of the angiographic projection. During PCI, there was a poor correlation between the best visual estimate of length and IVUS-derived measurements. In contrast, caliper-derived measurements correlated closely with IVUS-derived measurements. This handheld caliper provides a simple and accurate method of assessing intracoronary lesion length and may be particularly useful during coronary stenting and when adjunctive brachytherapy is performed. Copyright 2003 Wiley-Liss, Inc.

  8. Telomere length in interstitial lung diseases

    NARCIS (Netherlands)

    Snetselaar, Reinier; Van Moorsel, Coline H M; Kazemier, Karin M.; Van Der Vis, Joanne J.; Zanen, Pieter; Van Oosterhout, Matthijs F M; Grutters, Jan C.

    2015-01-01

    Background: Interstitial lung disease (ILD) is a heterogeneous group of rare diseases that primarily affect the pulmonary interstitium. Studies have implicated a role for telomere length (TL) maintenance in ILD, particularly in idiopathic interstitial pneumonia (IIP). Here, we measure TL in a wide

  9. Environmental stresses disrupt telomere length homeostasis.

    Directory of Open Access Journals (Sweden)

    Gal Hagit Romano

    Full Text Available Telomeres protect the chromosome ends from degradation and play crucial roles in cellular aging and disease. Recent studies have additionally found a correlation between psychological stress, telomere length, and health outcome in humans. However, studies have not yet explored the causal relationship between stress and telomere length, or the molecular mechanisms underlying that relationship. Using yeast as a model organism, we show that stresses may have very different outcomes: alcohol and acetic acid elongate telomeres, whereas caffeine and high temperatures shorten telomeres. Additional treatments, such as oxidative stress, show no effect. By combining genome-wide expression measurements with a systematic genetic screen, we identify the Rap1/Rif1 pathway as the central mediator of the telomeric response to environmental signals. These results demonstrate that telomere length can be manipulated, and that a carefully regulated homeostasis may become markedly deregulated in opposing directions in response to different environmental cues.

  10. Ultrasonographic assessment of renal length in 310 Turkish children ...

    African Journals Online (AJOL)

    Scanning was performed with a 3.5 MHz ultrasound probe in the supine position. The ultrasonographic appearance of the kidneys we measured was normal. The maximum length of each kidney was measured. The renal length was correlated with somatic parameters including age, body height and weight. Regression ...

  11. Ultrasound Assessment of Cervical Length in Pregnancy

    Directory of Open Access Journals (Sweden)

    An-Shine Chao

    2008-09-01

    Full Text Available Cervical length in high-risk women for preterm birth has to be identified before early second trimester. Sequential evaluations lead to high predictive significance. The mean cervical length at 24 weeks is about 35 mm when measured by transvaginal ultrasound. A short cervix is defined as a cervix that is less than 25 mm and funneling, i.e. ballooning of the membranes into a dilated internal os, but with a closed external os. Factors such as short cervical length, uterine anomaly, previous cervical surgery, multiple gestation and positive fetal fibronectin results are associated with preterm delivery. Serial transvaginal ultrasound examinations during the early second trimester would provide longitudinal changes in the cervical length. The use of 17α-hydroxyprogesterone caproate and cerclage has shown to be beneficial in preventing preterm delivery. When combined with other predictors such as occiput position, parity, maternal age and body mass index, cervical length is a useful parameter for predicting the feasibility of labor induction and successful delivery.

  12. Functional scoliosis caused by leg length discrepancy

    Science.gov (United States)

    Daniszewska, Barbara; Zolynski, Krystian

    2010-01-01

    Introduction Leg length discrepancy (LLD) causes pelvic obliquity in the frontal plane and lumbar scoliosis with convexity towards the shorter extremity. Leg length discrepancy is observed in 3-15% of the population. Unequalized lower limb length discrepancy leads to posture deformation, gait asymmetry, low back pain and discopathy. Material and methods In the years 1998-2006, 369 children, aged 5 to 17 years (209 girls, 160 boys) with LLD-related functional scoliosis were treated. An external or internal shoe lift was applied. Results Among 369 children the discrepancy of 0.5 cm was observed in 27, 1 cm in 329, 1.5 cm in 9 and 2 cm in 4 children. During the first follow-up examination, within 2 weeks, the adjustment of the spine to new static conditions was noted and correction of the curve in 316 examined children (83.7%). In 53 children (14.7%) the correction was observed later and was accompanied by slight low back pain. The time needed for real equalization of limbs was 3 to 24 months. The time needed for real equalization of the discrepancy was 11.3 months. Conclusions Leg length discrepancy equalization results in elimination of scoliosis. Leg length discrepancy < 2 cm is a static disorder; that is why measurements should be performed in a standing position using blocks of adequate thickness and the position of the posterior superior iliac spine should be estimated. PMID:22371777

  13. The length of the glaciers in the world

    DEFF Research Database (Denmark)

    Machguth, Horst; Huss, M.; Huss, M.

    2014-01-01

    Glacier length is an important measure of glacier geometry but global glacier inventories are mostly lacking length data. Only recently semi-automated approaches to measure glacier length have been developed and applied regionally. Here we present 5 a first global assessment of glacier length using...... a fully automated method based on glacier surface slope, distance to the glacier margins and a set of trade-off functions. The method is developed for East Greenland, evaluated for the same area as well as for Alaska, and eventually applied to all ∼ 200000 glaciers around the globe. The evaluation...... highlights accurately calculated glacier length where DEM quality is good (East 10 Greenland) and limited precision on low quality DEMs (parts of Alaska). Measured length of very small glaciers is subject to a certain level of ambiguity. The global calculation shows that only about 1.5% of all glaciers...

  14. Generation of Length Distribution, Length Diagram, Fibrogram, and Statistical Characteristics by Weight of Cotton Blends

    Directory of Open Access Journals (Sweden)

    B. Azzouz

    2007-01-01

    Full Text Available The textile fibre mixture as a multicomponent blend of variable fibres imposes regarding the proper method to predict the characteristics of the final blend. The length diagram and the fibrogram of cotton are generated. Then the length distribution, the length diagram, and the fibrogram of a blend of different categories of cotton are determined. The length distributions by weight of five different categories of cotton (Egyptian, USA (Pima, Brazilian, USA (Upland, and Uzbekistani are measured by AFIS. From these distributions, the length distribution, the length diagram, and the fibrogram by weight of four binary blends are expressed. The length parameters of these cotton blends are calculated and their variations are plotted against the mass fraction x of one component in the blend .These calculated parameters are compared to those of real blends. Finally, the selection of the optimal blends using the linear programming method, based on the hypothesis that the cotton blend parameters vary linearly in function of the components rations, is proved insufficient.

  15. Information-theoretic lengths of Jacobi polynomials

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero, A; Dehesa, J S [Departamento de Fisica Atomica, Molecular y Nuclear, Universidad de Granada, Granada (Spain); Sanchez-Moreno, P, E-mail: agmartinez@ugr.e, E-mail: pablos@ugr.e, E-mail: dehesa@ugr.e [Instituto ' Carlos I' de Fisica Teorica y Computacional, Universidad de Granada, Granada (Spain)

    2010-07-30

    The information-theoretic lengths of the Jacobi polynomials P{sup ({alpha}, {beta})}{sub n}(x), which are information-theoretic measures (Renyi, Shannon and Fisher) of their associated Rakhmanov probability density, are investigated. They quantify the spreading of the polynomials along the orthogonality interval [- 1, 1] in a complementary but different way as the root-mean-square or standard deviation because, contrary to this measure, they do not refer to any specific point of the interval. The explicit expressions of the Fisher length are given. The Renyi lengths are found by the use of the combinatorial multivariable Bell polynomials in terms of the polynomial degree n and the parameters ({alpha}, {beta}). The Shannon length, which cannot be exactly calculated because of its logarithmic functional form, is bounded from below by using sharp upper bounds to general densities on [- 1, +1] given in terms of various expectation values; moreover, its asymptotics is also pointed out. Finally, several computational issues relative to these three quantities are carefully analyzed.

  16. Bunch length and the 102/90 degrees optics

    CERN Document Server

    Lamont, M

    1998-01-01

    The bunch length in LEP has become a cause for concern, particularly in the ramp to high energies. Short bunch lengths excite higher order modes which can cause heating of the inter-cavity bellows a nd may be picked up by antennae cables causing burning. The bunch length is also important from a cryogenics viewpoint; HOM losses go up with shorter bunches and more cryogenics power is required. Measurements made during 1997 show that it is strongly advisable to maintain bunch lengths above 9 mm particularly with high bunch currents. The use of a low emittance lattice such as 102/90 degr ees exacerbates the problem; because of the decreased momentum compaction the bunch lengths are naturally shorter. This paper quantifies the bunch lengths to be expected at various stages of ope ration in 1998 and presents recommendations for the avoidance of bunch lengths shorter than 9 mm.

  17. Predicting length of stay in specialist neurological rehabilitation.

    Science.gov (United States)

    Taiwo, Whitney; Wressle, Alexandra; Bradley, Lloyd

    2018-03-01

    A retrospective case series was performed to determine which measures of complexity, dependency and function most accurately predict inpatient neurorehabilitation length of stay for individuals with post-acute neurological disorders. Sociodemographic, medical and functional variables were extracted from data submitted to the UK Rehabilitation Outcomes Collaborative. Length of stay was calculated as the total number of inpatient days, functional status was measured using Barthel Index, rehabilitation complexity was measured using Extended Rehabilitation Complexity Scale, and nursing dependency was measured using the Northwick Park Dependency Scale. The mean rehabilitation length of stay was 70.9 days, with length of stay being 35.1 days higher in inpatients with acquired brain injury than inpatients with spinal cord injury. Diagnostic category, Barthel Index scores, Extended Rehabilitation Complexity Scale scores and Northwick Park Dependency Scale scores at admission independently predicted length of stay. Multiple regressions including diagnostic group, Barthel Index, Extended Rehabilitation Complexity Scale and Northwick Park Dependency Scale statistically significantly predicted 37.9% of the variability in length of stay (p Scale on admission was most closely correlated with inpatient length of stay. In conclusion, inpatient length of stay is predicted by diagnostic category, Extended Rehabilitation Complexity Scale, Northwick Park Dependency Scale and Barthel Index. The most influential predictor of rehabilitation length of stay was Northwick Park Dependency Scale score at admission. These results may help facilitate rehabilitation resource planning and implementation of effective commissioning plans. Implications for Rehabilitation The most accurate predicting variable for length of stay in inpatient neurological rehabilitation was nursing need as measured by the Northwick Park Dependency Scale score on admission. Service users and commissioners can be

  18. Crack Length Detection by Digital Image Processing

    DEFF Research Database (Denmark)

    Lyngbye, Janus; Brincker, Rune

    1990-01-01

    It is described how digital image processing is used for measuring the length of fatigue cracks. The system is installed in a Personal Computer equipped with image processing hardware and performs automated measuring on plane metal specimens used in fatigue testing. Normally one can not achieve...... a resolution better then that of the image processing equipment. To overcome this problem an extrapolation technique is used resulting in a better resolution. The system was tested on a specimen loaded with different loads. The error σa was less than 0.031 mm, which is of the same size as human measuring...

  19. A 13 kA current lead, measuring 1.5 m in length. The lower part consists of a high-temperature superconductor (Bi-2223), operating at between 50 K and 4.5 K, while the heat-exchanger upper part allows the current to be brought from room temperature to 50 K.

    CERN Multimedia

    2004-01-01

    A 13 kA current lead, measuring 1.5 m in length. The lower part consists of a high-temperature superconductor (Bi-2223), operating at between 50 K and 4.5 K, while the heat-exchanger upper part allows the current to be brought from room temperature to 50 K.

  20. New plasma diagnosis by coherence length spectroscopy

    International Nuclear Information System (INIS)

    Poolyarat, N.; Kim, Y.W.

    2008-01-01

    A new methodology and instrumentation have been developed for diagnosis of dense high temperature plasmas. In a plasma medium, collision processes shorten the optical coherence length at a given emission wavelength. By measuring the coherence length, the rate of collisions a radiating particle experiences can be determined. A map of the collision rates throughout the plasma can speak volumes about the atomic and thermal state of the plasma. Both the time-integrated and time-resolved interference fringes are obtained using emissions due to the transition between 3s 2 3p 5 ( 2 P o 3/2 )4p and 3s 2 3p 5 ( 2 P o 3/2 )7d. We have observed that the coherence length indeed decreases with increasing collision rate, and in addition, as a function of time as a result of cumulative collisions. The coherence length was found to be 4200±800 nm at 50 torr where the collision frequency is 2.14x10 11 s -1 , and 2400±130 nm at 140 torr where the collision frequency is 8.13x10 11 s -1 . We have also discovered that the coherence length varies with the direction of the viewing line of sight into the discharge plasma. The anisotropy results from the non-uniform structure in the discharge current, and this is further investigated by intentionally deforming the tip of the cathode. A photographic examination of both the cathode and the anode disc confirms the non-axis-symmetric structure of the plasma, which leads to the asymmetry in the plasma, in agreement with the angular dependence of the coherence length. (author)

  1. Nosology and Measurement in Child and Adolescent Psychiatry

    Science.gov (United States)

    Angold, Adrian; Costello, E. Jane

    2009-01-01

    The last 50 years have witnessed enormous strides in the measurement and classification of child and adolescent psychiatric disorders. Debates about whether we should continue to depend upon a categorical nosology still continue, but we argue that, despite the absence of clear dividing lines between psychiatric disorders and normality and ubiquity…

  2. Fibre operating lengths of human lower limb muscles during walking.

    Science.gov (United States)

    Arnold, Edith M; Delp, Scott L

    2011-05-27

    Muscles actuate movement by generating forces. The forces generated by muscles are highly dependent on their fibre lengths, yet it is difficult to measure the lengths over which muscle fibres operate during movement. We combined experimental measurements of joint angles and muscle activation patterns during walking with a musculoskeletal model that captures the relationships between muscle fibre lengths, joint angles and muscle activations for muscles of the lower limb. We used this musculoskeletal model to produce a simulation of muscle-tendon dynamics during walking and calculated fibre operating lengths (i.e. the length of muscle fibres relative to their optimal fibre length) for 17 lower limb muscles. Our results indicate that when musculotendon compliance is low, the muscle fibre operating length is determined predominantly by the joint angles and muscle moment arms. If musculotendon compliance is high, muscle fibre operating length is more dependent on activation level and force-length-velocity effects. We found that muscles operate on multiple limbs of the force-length curve (i.e. ascending, plateau and descending limbs) during the gait cycle, but are active within a smaller portion of their total operating range.

  3. Continuously variable focal length lens

    Science.gov (United States)

    Adams, Bernhard W; Chollet, Matthieu C

    2013-12-17

    A material preferably in crystal form having a low atomic number such as beryllium (Z=4) provides for the focusing of x-rays in a continuously variable manner. The material is provided with plural spaced curvilinear, optically matched slots and/or recesses through which an x-ray beam is directed. The focal length of the material may be decreased or increased by increasing or decreasing, respectively, the number of slots (or recesses) through which the x-ray beam is directed, while fine tuning of the focal length is accomplished by rotation of the material so as to change the path length of the x-ray beam through the aligned cylindrical slows. X-ray analysis of a fixed point in a solid material may be performed by scanning the energy of the x-ray beam while rotating the material to maintain the beam's focal point at a fixed point in the specimen undergoing analysis.

  4. Kondo length in bosonic lattices

    Science.gov (United States)

    Giuliano, Domenico; Sodano, Pasquale; Trombettoni, Andrea

    2017-09-01

    Motivated by the fact that the low-energy properties of the Kondo model can be effectively simulated in spin chains, we study the realization of the effect with bond impurities in ultracold bosonic lattices at half filling. After presenting a discussion of the effective theory and of the mapping of the bosonic chain onto a lattice spin Hamiltonian, we provide estimates for the Kondo length as a function of the parameters of the bosonic model. We point out that the Kondo length can be extracted from the integrated real-space correlation functions, which are experimentally accessible quantities in experiments with cold atoms.

  5. Quantitative fluorescence spectroscopy in turbid media using fluorescence differential path length spectroscopy

    NARCIS (Netherlands)

    Amelink, Arjen; Kruijt, Bastiaan; Robinson, Dominic J.; Sterenborg, Henricus J. C. M.

    2008-01-01

    We have developed a new technique, fluorescence differential path length spectroscopy (FDPS), that enables the quantitative investigation of fluorophores in turbid media. FDPS measurements are made with the same probe geometry as differential path length spectroscopy (DPS) measurements. Phantom

  6. Newton's Radii, Maupertuis' Arc Length, and Voltaire's Giant

    Science.gov (United States)

    Simoson, Andrew J.

    2011-01-01

    Given two arc length measurements along the perimeter of an ellipse--one taken near the long diameter, the other taken anywhere else--how do you find the lengths of major and minor axes? This was a problem of great interest from the time of Newton's "Principia" until the mid-eighteenth century when France launched twin geodesic…

  7. Length-Weight Relationships and Food Preference of Two Coastal ...

    African Journals Online (AJOL)

    Length-weight measurements were taken from well-preserved fish specimens from which stomachs were extracted for the analysis of the food contents, using frequency of occurrence, numerical and gravimetric methods, as well as index of relative importance. The length-frequency analysis showed a size distribution with a ...

  8. Working Length Determination of Root Canal of Young Permanent ...

    African Journals Online (AJOL)

    Working length was measured by tactile method using digital radiography and electronic method using apex locator with no 15 K file. Actual working length was established by grinding of cementum and dentine from the root apex and was observed under stereomicroscope. Data was collected and statistical analysis was ...

  9. Heritability of sperm length in the bumblebee Bombus terrestris

    DEFF Research Database (Denmark)

    Baer, Boris; de Jong, Gerdien; Schmid-Hempel, Regula

    2006-01-01

    Sperm length is highly variable, both between and within species, but the evolutionary significance of this variation is poorly understood. Sexual selection on sperm length requires a significant additive genetic variance, but few studies have actually measured this. Here we present the first est...

  10. Resonance and Neck Length for a Spherical Resonator

    Directory of Open Access Journals (Sweden)

    Emily Corning

    2011-06-01

    Full Text Available The relationship between the neck length of a spherical resonator and its period of fundamental resonance was investigated. This was done by measuring the frequency of fundamental resonance of the resonator at 6 different neck lengths. It was found that its resonance resembled Helmholtz resonance but was not that of ideal Helmholtz resonance.

  11. Length-weight relationship and condition factor of clarias gariepinus ...

    African Journals Online (AJOL)

    Length-Weight relationship and condition factor of Clarias gariepinus and Tilapia Zillii were studiedin lake Alau and Monguno hatchery, both in Borno State of Nigeria, for a period of two weeks. A total of 98 C. gariepinus and 140. T. zillii were measured. The length-weight regression coefficient (b) for both fishes in lake Alau ...

  12. Cyclic codes of length 2

    Indian Academy of Sciences (India)

    Springer Verlag Heidelberg #4 2048 1996 Dec 15 10:16:45

    [X]/〈X2m. − 1〉 are given. Cyclic codes of length 2m over the finite field Fq, of odd characteristic, are defined in terms of their generator polynomials. The exact minimum distance and the dimension of the codes are obtained. Keywords.

  13. Diet, nutrition and telomere length.

    Science.gov (United States)

    Paul, Ligi

    2011-10-01

    The ends of human chromosomes are protected by DNA-protein complexes termed telomeres, which prevent the chromosomes from fusing with each other and from being recognized as a double-strand break by DNA repair proteins. Due to the incomplete replication of linear chromosomes by DNA polymerase, telomeric DNA shortens with repeated cell divisions until the telomeres reach a critical length, at which point the cells enter senescence. Telomere length is an indicator of biological aging, and dysfunction of telomeres is linked to age-related pathologies like cardiovascular disease, Parkinson disease, Alzheimer disease and cancer. Telomere length has been shown to be positively associated with nutritional status in human and animal studies. Various nutrients influence telomere length potentially through mechanisms that reflect their role in cellular functions including inflammation, oxidative stress, DNA integrity, DNA methylation and activity of telomerase, the enzyme that adds the telomeric repeats to the ends of the newly synthesized DNA. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. Femur length and biparietal diameter

    African Journals Online (AJOL)

    2014-12-02

    Dec 2, 2014 ... Shipp TD, Bromley B, Mascola M, Benacerraf B. Variation in fetal femur length with respect to maternal race. J Ultrasound Med 2001;20:141‑4. 25. Deter RL, Harrist RB, Birnholz JC, Hadlock FP. Quantitative Obstetrical. Ultrasonography. New York: Wiley; 1986. 26. Yeh MN, Bracero L, Reilly KB, Murtha L, ...

  15. ESTIMATION OF STATURE BASED ON FOOT LENGTH

    Directory of Open Access Journals (Sweden)

    Vidyullatha Shetty

    2015-01-01

    Full Text Available BACKGROUND : Stature is the height of the person in the upright posture. It is an important measure of physical identity. Estimation of body height from its segments or dismember parts has important considerations for identifications of living or dead human body or remains recovered from disasters or other similar conditions. OBJECTIVE : Stature is an important indicator for identification. There are numerous means to establish stature and their significance lies in the simplicity of measurement, applicability and accuracy in prediction. Our aim of the study was to review the relationship between foot length and body height. METHODS : The present study reviews various prospective studies which were done to estimate the stature. All the measurements were taken by using standard measuring devices and standard anthropometric techniques. RESULTS : This review shows there is a correlation between stature and foot dimensions it is found to be positive and statistically highly significant. Prediction of stature was found to be most accurate by multiple regression analysis. CONCLUSIONS : Stature and gender estimation can be done by using foot measurements and stud y will help in medico - legal cases in establishing identity of an individual and this would be useful for Anatomists and Anthropologists to calculate stature based on foot length

  16. Length-scale dependent phonon interactions

    CERN Document Server

    Srivastava, Gyaneshwar

    2014-01-01

    This book presents  a comprehensive description of phonons and their interactions in systems with different dimensions and length scales. Internationally-recognized leaders describe theories and measurements of phonon interactions  in relation to the design of materials with exotic properties such as metamaterials, nano-mechanical systems, next-generation electronic, photonic, and acoustic devices, energy harvesting, optical information storage, and applications of phonon lasers in a variety of fields. The emergence of techniques for control of semiconductor properties and geometry has enabled engineers to design structures in which functionality is derived from controlling electron behavior. As manufacturing techniques have greatly expanded the list of available materials and the range of attainable length scales, similar opportunities now exist for designing devices whose functionality is derived from controlling phonon behavior. However, progress in this area is hampered by gaps in our knowledge of phono...

  17. Electron attenuation lengths in fullerene and fullerides

    International Nuclear Information System (INIS)

    Li Hongnian; Wang Xiaoxiong; Ding Wangfeng

    2006-01-01

    Using X-ray photoemission measurements, we have determined the attenuation length of C 1s photoelectrons in C 60 film to be 21.5 A with the incident photon energy of Mg Kα radiation. The inelastic mean free path calculated with the TPP-2M algorithm coincides fairly well with the experimentally determined attenuation length, indicating the validity of the algorithm to fullerene and fullerides. The inelastic mean free paths for some fullerides, i.e. K 3 C 60 , K 6 C 60 , Ba 4 C 60 , Sm 2.75 C 60 and Sm 6 C 60 are calculated to help the quantitative analyses of the photoemission spectra for these compounds

  18. Impact of Cyclic Prefix length on OFDM system Capacity

    DEFF Research Database (Denmark)

    Rom, Christian; Sørensen, Troels Bundgaard; Mogensen, Preben Elgaard

    2005-01-01

    This paper is a study on the impact of the Cyclic Prefix (CP) length on the downlink Capacity in a base-band synchronized SISO-OFDM context. To measure this impact, the capacity, measured in bits per second per hertz, is chosen as quality parameter. The study shows how the lengthening of the CP......) the useful OFDM symbol duration, 2) the Signal to Noise Ratio (SNR) at the receiver and 3) the channel Power Delay Profile (PDP). Depending on the values of these parameters different optimum CP lengths are obtained. For a system using only one value of CP length we suggest an optimum value to be 4us...... for an OFDM symbol length of 40us and 6us for an OFDM symbol length of 80us....

  19. Length of a Hanging Cable

    Directory of Open Access Journals (Sweden)

    Eric Costello

    2011-01-01

    Full Text Available The shape of a cable hanging under its own weight and uniform horizontal tension between two power poles is a catenary. The catenary is a curve which has an equation defined by a hyperbolic cosine function and a scaling factor. The scaling factor for power cables hanging under their own weight is equal to the horizontal tension on the cable divided by the weight of the cable. Both of these values are unknown for this problem. Newton's method was used to approximate the scaling factor and the arc length function to determine the length of the cable. A script was written using the Python programming language in order to quickly perform several iterations of Newton's method to get a good approximation for the scaling factor.

  20. Keeping disease at arm's length

    DEFF Research Database (Denmark)

    Lassen, Aske Juul

    2015-01-01

    and physical activities at the activity centre. In this way, keeping disease at arm’s length is analysed as an ambiguous health strategy. The article shows the importance of looking into how active ageing is practised, as active ageing seems to work well in the everyday life of the older people by not giving......Many older people live with a range of chronic diseases. However, these diseases do not necessarily impede an active lifestyle. In this article the author analyses the relation between the active ageing discourse and the way older people at two Danish activity centres handle disease. How does...... active ageing change everyday life with chronic disease, and how do older people combine an active life with a range of chronic diseases? The participants in the study use activities to keep their diseases at arm’s length, and this distancing of disease at the same time enables them to engage in social...

  1. Determining multiple length scales in rocks

    Science.gov (United States)

    Song, Yi-Qiao; Ryu, Seungoh; Sen, Pabitra N.

    2000-07-01

    Carbonate reservoirs in the Middle East are believed to contain about half of the world's oil. The processes of sedimentation and diagenesis produce in carbonate rocks microporous grains and a wide range of pore sizes, resulting in a complex spatial distribution of pores and pore connectivity. This heterogeneity makes it difficult to determine by conventional techniques the characteristic pore-length scales, which control fluid transport properties. Here we present a bulk-measurement technique that is non-destructive and capable of extracting multiple length scales from carbonate rocks. The technique uses nuclear magnetic resonance to exploit the spatially varying magnetic field inside the pore space itself-a `fingerprint' of the pore structure. We found three primary length scales (1-100µm) in the Middle-East carbonate rocks and determined that the pores are well connected and spatially mixed. Such information is critical for reliably estimating the amount of capillary-bound water in the rock, which is important for efficient oil production. This method might also be used to complement other techniques for the study of shaly sand reservoirs and compartmentalization in cells and tissues.

  2. Diagnostic value of newborn foot length to predict gestational age

    Directory of Open Access Journals (Sweden)

    Mutia Farah Fawziah

    2017-08-01

    Full Text Available Background  Identification of gestational age, especially within 48 hours of birth, is crucial for newborns, as the earlier preterm status is detected, the earlier the child can receive optimal management. Newborn foot length is an anthropometric measurement which is easy to perform, inexpensive, and potentially efficient for predicting gestational age. Objective  To analyze the diagnostic value of newborn foot length in predicting gestational age. Methods  This diagnostic study was performed between October 2016 and February 2017 in the High Care Unit of Neonates at Dr. Moewardi General Hospital, Surakarta. A total of 152 newborns were consecutively selected and underwent right foot length measurements before 96 hours of age. The correlation between newborn foot length to classify as full term and gestational age was analyzed with Spearman’s correlation test because of non-normal data distribution. The cut-off point of newborn foot length was calculated by receiver operating characteristic (ROC curve and diagnostic values of newborn foot length were analyzed by 2 x 2 table with SPSS 21.0 software. Results There were no significant differences between male and female newborns in terms of gestational age, birth weight, choronological age, and newborn foot length (P>0.05. Newborn foot length and gestational age had a significant correlation (r=0.53; P=0.000. The optimal cut-off newborn foot length to predict full term status was 7.1 cm. Newborn foot length below 7.1 cm had sensitivity 75%, specificity 98%, positive predictive value 94.3%, negative predictive value 90.6%, positive likelihood ratio 40.5, negative likelihood ratio 0.25, and post-test probability 94.29%, to predict preterm status in newborns. Conclusion  Newborn foot length can be used to predict gestational age, especially for the purpose of differentiating between preterm and full term newborns.

  3. Length of urethra in the Indian adult male population

    Directory of Open Access Journals (Sweden)

    Venkatesh Krishnamoorthy

    2012-01-01

    Full Text Available Objective: The urethral length has not been measured in the Indian population. Even the international literature in this arena is very sparse. This paper is an attempt to develop a simple anatomical database for urethral length. Materials and Methods: Between January 2010 and April 2011, the urethral lengths of 422 adult male patients who required catheterization as part of regular treatment at our hospital, were recorded after obtaining consent from the patients and from the scientific and ethics review boards of the institution. Patients with history of prostatic or urethral abnormalities were excluded. The balloon of a sterile Foley′s catheter was inflated using 10 cc of saline. The length from the junction of the balloon to the ′Y′ junction of the Foley was measured. The catheter was then passed into the bladder and re-inflated to same volume. The penis was gently straightened and the length of the catheter outside the penis was measured till the premarked point at the ′Y′ junction. Subtracting this from the original length gave the length of the urethra. Results: The mean length of the urethra was 17.55 + 1.42 cm with a range between 14 and 22.5 cm. Conclusions: Literature in which the length of the normal adult male urethra is recorded for a significant sample size is very scarce. Our data adds to basic anatomic information of the male urethra specific to the Indian population. Statistical Methods: Descriptive statistical analysis was performed. The non-linear regression analysis was employed to find the normative values of urethral length according to age class.

  4. Evaluation of Efficient Line Lengths for Better Readability

    Directory of Open Access Journals (Sweden)

    Zahid Hussain

    2012-01-01

    Full Text Available In this paper the major findings of a formal experiment about onscreen text line lengths are presented. The experiment examined the effects of four different line lengths on the reading speed and the reading efficiency. Efficiency is defined as a combination of reading speed and accuracy. Sixteen people between the age of 24 and 36 participated at the experiment. The subjects had to read four different texts with an average line length around 2000 characters. The texts contained substitution words, which had to be detected by the subjects to measure reading accuracy. Besides objective measures like reading speed and accuracy, the subjects were asked to subjectively vote on their reading experience. The results from our objective measures show strong similarities to those of the work done previously by different researchers. The absolute reading speed grows when the line length grows from CPL (Characters Per Line 30-120. The measured reading efficiency, however, doesn\\\\\\'t grow steadily, although a growing trend can be seen. This is due to the fact, that the test persons found in average more substitution words from the 60 CPL text than they did from the 30 and 90 CPL texts. The reading speed seems to increase while the line length increases but the overall comprehension seems to peak at medium line lengths. As in the previous studies, our test persons also prefer the medium (60 and 90 CPL line lengths, although they perform better when reading longer lines. In the overall subjective opinion 13 out of 16 test persons selected the 60 or 90 CPL line length as their favorite. The literature doesn\\\\\\'t truly provide a scientific explanation for the difference between the objective performance and the subjective preference. A natural hypothesis would be that the line length that is the fastest to read would also feel most comfortable to the readers but in the light of this and the earlier research it seems like this is not the case.

  5. Sperm length evolution in the fungus-growing ants

    DEFF Research Database (Denmark)

    Baer, B.; Dijkstra, M. B.; Mueller, U. G.

    2009-01-01

    Eusocial insects offer special opportunities for the comparative study of sperm traits because sperm competition is absent (in species with obligatory monandry) or constrained (in lineages where queens mate multiply but never remate later in life). We measured sperm length in 19 species of fungus......-growing ants, representing 9 of the 12 recognized genera, and mapped these onto the ant phylogeny. We show that average sperm length across species is highly variable and decreases with mature colony size in basal genera with singly mated queens, suggesting that sperm production or storage constraints affect...... the evolution of sperm length. Sperm length does not decrease further in multiply mating leaf-cutting ants, despite substantial further increases in colony size. In a combined analysis, sexual dimorphism explained 63.1% of the variance in sperm length between species. As colony size was not a significant...

  6. Measurement Engineering

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jun Hui; Kim, Hyeong Cheol

    2001-08-15

    This book deals with conception of measurement such as measuring and test, instrument for measurement, and types and methods of measuring, general things for precision measurement like indicator, gauge standard and Abbe's principle, measuring instrument such as vernier calipers, micrometer calipers, each gage, an optical instrument, and 3D instrument, choice and using of measuring instrument on length measurement, angle measurement, and side measurement, application and calculation for measuring using trigonometrical function, sin law, and the Pythagorean Theorem.

  7. Bulk measurement of copper and sodium content in CuIn(0.7)Ga(0.3)Se(2) (CIGS) solar cells with nanosecond pulse length laser induced breakdown spectroscopy (LIBS)

    OpenAIRE

    Kowalczyk, Jeremy M. D.; Perkins, Jeffrey J.; DeAngelis, Alexander; Kaneshiro, Jess; Mallory, Stewart A.; Chang, Yuancheng; Gaillard, Nicolas

    2013-01-01

    In this work, we show that laser induced breakdown spectroscopy (LIBS) with a nanosecond pulse laser can be used to measure the copper and sodium content of CuIn(0.7)Ga(0.3)Se(2) (CIGS) thin film solar cells on molybdenum. This method has four significant advantages over methods currently being employed: the method is inexpensive, measurements can be taken in times on the order of one second, without high vacuum, and at distances up to 5 meters or more. The final two points allow for in-line ...

  8. Do cell phones affect establishing electronic working length?

    Science.gov (United States)

    Hurstel, Justine; Guivarc'h, Maud; Pommel, Ludovic; Camps, Jean; Tassery, Hervé; Cohen, Stephen; Bukiet, Frédéric

    2015-06-01

    Patients often keep their cell phones on and nearby during root canal therapy. Cell phones release electromagnetic interference, which might disturb electronic working length measurements. The purpose of this ex vivo study was to determine the effect of a cell phone (Apple iPhone 5 [Apple, Cupertino, CA] or KP100 [LG, Seoul, Korea]) placed into direct contact with an electronic apex locator (EAL) (Dentaport Root ZX module [J Morita Corp, Tokyo, Japan] or Propex II [Dentsply Maillefer, Ballaigues, Switzerland]) on working length determination. Twenty-six human premolars without fractures or carious lesions were used; previously cleaned; and observed under magnification (×15) in order to check for the presence of only 1 apical foramen, the absence of apical resorption, an "open" apex, and accessory canals. The working length measurement was performed with a #15 K-file in the presence of 2.6% sodium hypochlorite under 4 conditions: (1) visually, under the microscope until the file tip reached the canal terminus; (2) electronically, without the cell phone in proximity; (3) electronically, with the cell phone in standby mode placed in physical contact with the EAL; and (4) electronically, with the cell phone activated by a call in the same position. The experimental model for electronic working length determination was a screw top plastic container filled with a saline solution. The measurements were repeated 3 times per canal under each condition. Scores of 1 to 3 categorized the stability of the readings as follows: (1) good stability; (2) unstable reading with minor difficulties determining the working length; and (3) major difficulties or impossible to determine the working length. A 2-way repeated measures analysis of variance (way 1: cell phone type and way 2: EAL model) was performed, and a second repeated measures analysis of variance was performed to seek a difference among the 4 working length determination conditions. Neither the cell phone type nor the EAL

  9. Cervical length assessment in women with idiopathic polyhydramnios.

    Science.gov (United States)

    Hershkovitz, R; Sheiner, E; Maymon, E; Erez, O; Mazor, M

    2006-11-01

    The aims of the study were to determine cervical length among patients with polyhydramnios and to assess the relationship between the severity of polyhydramnios, cervical length and gestational age at delivery. A prospective study was designed including 92 consecutive singleton pregnancies with polyhydramnios between 24 and 40 weeks' gestation. Cervical length was measured using transvaginal sonography. Polyhydramnios was defined when amniotic fluid index (AFI) was equal to or greater than 20 cm. A single sonologist performed all the examinations of the cervical length and the AFI. The median cervical length and AFI were 37.5 (range, 7-52) mm and 28.8 (range, 20-43) cm, respectively. A significant gradual shortening of the cervical length was observed with advancing gestational age (P=0.027). No significant association was found between AFI and cervical length (P=0.24). A cut-off of 15 mm (n=5) was associated with a significantly lower gestational age at delivery (30+/-2.6 weeks vs. 37.2+/-4.2 weeks, respectively, Ppolyhydramnios have a gradual shortening of cervical length with advancing gestational age. However, this finding is not related to the severity of polyhydramnios. Copyright (c) 2006 ISUOG.

  10. Smart Photonic Carbon Brush: FBG Length as Sensing Parameter

    Science.gov (United States)

    Morozov, O. G.; Nureev, I. I.; Kuznetsov, A. A.; Artemiev, V. I.

    2018-04-01

    This article deals with problem of carbon brush’s length measurements. There are many applications where regular inspection is not feasible because of a number of factors including, for example, time, labor, cost and disruptions due to down time. Thus, there is a need for a system that can monitor the brush’s length to calculate it’s wear rate, while the component is in operation or without removing of the component from its operational position. We propose a novel method for characterization of carbon brush’s length. This method based on the usage of advantages of the multiplicative response of FBGs and FBG arrays: spectral parameters depend on several aspects, such as grating’s period, refractive index, it’s physical length and so on. We are the first, in our point of view, who proposed to use third parameter for sensing application and prospectively all three parameters for complex measurement: the change of FBG’s length is used to measure length of the brush and it’s wear rate, grating’s central wavelength shift for temperature (due to refractive index change) and mechanical stress (due to grating’s period variations) measurements. The results of modelling and experiments are presented.

  11. An on-ice measurement approach to analyse the biomechanics of ice hockey skating.

    Directory of Open Access Journals (Sweden)

    Erica Buckeridge

    Full Text Available Skating is a fundamental movement in ice hockey; however little research has been conducted within the field of hockey skating biomechanics due to the difficulties of on-ice data collection. In this study a novel on-ice measurement approach was tested for reliability, and subsequently implemented to investigate the forward skating technique, as well as technique differences across skill levels. Nine high caliber (High and nine low caliber (Low hockey players performed 30 m forward skating trials. A 3D accelerometer was mounted to the right skate for the purpose of stride detection, with the 2nd and 6th strides defined as acceleration and steady-state, respectively. The activity of five lower extremity muscles was recorded using surface electromyography. Biaxial electro-goniometers were used to quantify hip and knee angles, and in-skate plantar force was measured using instrumented insoles. Reliability was assessed with the coefficient of multiple correlation, which demonstrated moderate (r>0.65 to excellent (r>0.95 scores across selected measured variables. Greater plantar-flexor muscle activity and hip extension were evident during acceleration strides, while steady state strides exhibited greater knee extensor activity and hip abduction range of motion (p<0.05. High caliber exhibited greater hip range of motion and forefoot force application (p<0.05. The successful implementation of this on-ice mobile measurement approach offers potential for athlete monitoring, biofeedback and training advice.

  12. An On-Ice Measurement Approach to Analyse the Biomechanics of Ice Hockey Skating

    Science.gov (United States)

    Buckeridge, Erica; LeVangie, Marc C.; Stetter, Bernd; Nigg, Sandro R.; Nigg, Benno M.

    2015-01-01

    Skating is a fundamental movement in ice hockey; however little research has been conducted within the field of hockey skating biomechanics due to the difficulties of on-ice data collection. In this study a novel on-ice measurement approach was tested for reliability, and subsequently implemented to investigate the forward skating technique, as well as technique differences across skill levels. Nine high caliber (High) and nine low caliber (Low) hockey players performed 30m forward skating trials. A 3D accelerometer was mounted to the right skate for the purpose of stride detection, with the 2nd and 6th strides defined as acceleration and steady-state, respectively. The activity of five lower extremity muscles was recorded using surface electromyography. Biaxial electro-goniometers were used to quantify hip and knee angles, and in-skate plantar force was measured using instrumented insoles. Reliability was assessed with the coefficient of multiple correlation, which demonstrated moderate (r>0.65) to excellent (r>0.95) scores across selected measured variables. Greater plantar-flexor muscle activity and hip extension were evident during acceleration strides, while steady state strides exhibited greater knee extensor activity and hip abduction range of motion (p<0.05). High caliber exhibited greater hip range of motion and forefoot force application (p<0.05). The successful implementation of this on-ice mobile measurement approach offers potential for athlete monitoring, biofeedback and training advice. PMID:25973775

  13. On the Effects of Heterogeneous Packet Lengths on Network Coding

    DEFF Research Database (Denmark)

    Compta, Pol Torres; Fitzek, Frank; Roetter, Daniel Enrique Lucani

    2014-01-01

    a best case scenario as coded packets will incur little overhead to handle such packets. However, packet lengths are quite heterogeneous in real networks, which can cause a high overhead or, alternatively, a high delay in the transmission of data packets. As we show, this can have a severe effect...... on a variety of applications. This paper proposes a series of mechanisms to manage heterogeneous packet lengths and analyzes the induced overhead of those mechanisms using real packet length distributions provided by CAIDA and own measurements using video content. Our results show that an appropriate...

  14. Electron Bunch Length Diagnostic With Coherent Smith-Purcell Radiation

    International Nuclear Information System (INIS)

    Nguyen, D.C.

    1997-01-01

    The authors have designed a new technique for measuring subpicosecond electron bunch lengths using coherent Smith-Purcell radiation. This new diagnostic technique involves passing the electron beam in close proximity of a grating with a period comparable to the electron bunch length. The emitted Smith-Purcell radiation will have a coherent component whose angular position and distribution are directly related to the electron bunch length and longitudinal profile, respectively. This new diagnostic technique is inherently simple, inexpensive and non-intercepting. The authors show that the new technique is also scaleable to femtosecond regime

  15. Fluid mixing in stratified gravity currents: the Prandtl mixing length.

    Science.gov (United States)

    Odier, P; Chen, J; Rivera, M K; Ecke, R E

    2009-04-03

    Shear-induced vertical mixing in a stratified flow is a key ingredient of thermohaline circulation. We experimentally determine the vertical flux of momentum and density of a forced gravity current using high-resolution velocity and density measurements. A constant eddy-viscosity model provides a poor description of the physics of mixing, but a Prandtl mixing length model relating momentum and density fluxes to mean velocity and density gradients works well. For the average gradient Richardson number Ri(g) approximately 0.08 and a Taylor Reynolds number Re(lambda) approximately 100, the mixing lengths are fairly constant, about the same magnitude, comparable to the turbulent shear length.

  16. An Assessment of the Length and Variability of Mercury's Magnetotail

    Science.gov (United States)

    Milan, S. E.; Slavin, J. A.

    2011-01-01

    We employ Mariner 10 measurements of the interplanetary magnetic field in the vicinity of Mercury to estimate the rate of magnetic reconnection between the interplanetary magnetic field and the Hermean magnetosphere. We derive a time-series of the open magnetic flux in Mercury's magnetosphere. from which we can deduce the length of the magnetotail The length of the magnetotail is shown to be highly variable. with open field lines stretching between 15R(sub H) and 8S0R(sub H) downstream of the planet (median 150R(sub H)). Scaling laws allow the tail length at perihelion to be deduced from the aphelion Mariner 10 observations.

  17. Sub-recoil cooling up to nano-Kelvin. Direct measurement of spatial coherency length. New tests for Levy statistics; Refroidissement laser subrecul au nanokelvin. Mesure directe de la longueur de coherence spatiale. Nouveaux tests des statistiques de Levy

    Energy Technology Data Exchange (ETDEWEB)

    Saubamea, B

    1998-12-15

    This thesis presents a new method to measure the temperature of ultracold atoms from the spatial autocorrelation function of the atomic wave-packets. We thus determine the temperature of metastable helium-4 atoms cooled by velocity selective dark resonance, a method known to cool the atoms below the temperature related to the emission or the absorption of a single photon by an atom at rest, namely the recoil temperature. This cooling mechanism prepares each atom in a coherent superposition of two wave-packets with opposite mean momenta, which are initially superimposed and then drift apart. By measuring the temporal decay of their overlap, we have access to the Fourier transform of the momentum distribution of the atoms. Using this method, we can measure temperatures as low as 5 nK, 800 times as small as the recoil temperature. Moreover we study in detail the exact shape of the momentum distribution and compare the experimental results with two different theoretical approaches: a quantum Monte Carlo simulation and an analytical model based on Levy statistics. We compare the calculated line shape with the one deduced from simulations, and each theoretical model with experimental data. A very good agreement is found with each approach. We thus demonstrate the validity of the statistical model of sub-recoil cooling and give the first experimental evidence of some of its characteristics: the absence of steady-state, the self-similarity and the non Lorentzian shape of the momentum distribution of the cooled atoms. All these aspects are related to the non ergodicity of sub-recoil cooling. (author)

  18. System for automatic gauge block length measurement optimized for secondary length metrology

    Czech Academy of Sciences Publication Activity Database

    Buchta, Zdeněk; Šarbort, Martin; Čížek, Martin; Hucl, Václav; Řeřucha, Šimon; Pikálek, Tomáš; Dvořáčková, Š.; Dvořáček, F.; Kůr, J.; Konečný, P.; Weigl, M.; Lazar, Josef; Číp, Ondřej

    2017-01-01

    Roč. 49, JULY (2017), s. 322-331 ISSN 0141-6359 R&D Projects: GA TA ČR(CZ) TA03010663; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : low-coherence interferometry * laser interferometry * Gauge block * metrology Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Optics (including laser optics and quantum optics) Impact factor: 2.237, year: 2016

  19. Quantum discord length is enhanced while entanglement length is not by introducing disorder in a spin chain.

    Science.gov (United States)

    Sadhukhan, Debasis; Roy, Sudipto Singha; Rakshit, Debraj; Prabhu, R; Sen De, Aditi; Sen, Ujjwal

    2016-01-01

    Classical correlation functions of ground states typically decay exponentially and polynomially, respectively, for gapped and gapless short-range quantum spin systems. In such systems, entanglement decays exponentially even at the quantum critical points. However, quantum discord, an information-theoretic quantum correlation measure, survives long lattice distances. We investigate the effects of quenched disorder on quantum correlation lengths of quenched averaged entanglement and quantum discord, in the anisotropic XY and XYZ spin glass and random field chains. We find that there is virtually neither reduction nor enhancement in entanglement length while quantum discord length increases significantly with the introduction of the quenched disorder.

  20. Leukocyte telomere length variation due to DNA extraction method.

    Science.gov (United States)

    Denham, Joshua; Marques, Francine Z; Charchar, Fadi J

    2014-12-04

    Telomere length is indicative of biological age. Shorter telomeres have been associated with several disease and health states. There are inconsistencies throughout the literature amongst relative telomere length measured by quantitative PCR (qPCR) and different extraction methods or kits used. We quantified whole-blood leukocyte telomere length using the telomere to single copy gene (T/S) ratio by qPCR in 20 young (18-25 yrs) men after extracting DNA using three common extraction methods: Lahiri and Nurnberger (high salt) method, PureLink Genomic DNA Mini kit (Life Technologies) and QiaAmp DNA Mini kit (Qiagen). Telomere length differences of DNA extracted from the three extraction methods was assessed by one-way analysis of variance (ANOVA). DNA purity differed between extraction methods used (P=0.01). Telomere length was impacted by the DNA extraction method used (P=0.01). Telomeres extracted using the Lahiri and Nurnberger method (mean T/S ratio: 2.43, range: 1.57-3.02) and PureLink Genomic DNA Mini Kit (mean T/S ratio: 2.57, range: 2.24-2.80) did not differ (P=0.13). Likewise, QiaAmp and Purelink-extracted telomeres were not statistically different (P=0.14). The Lahiri-extracted telomeres, however, were significantly shorter than those extracted using the QiaAmp DNA Mini Kit (mean T/S ratio: 2.71, range: 2.32-3.02; P=0.003). DNA purity was associated with telomere length. There are discrepancies between the length of leukocyte telomeres extracted from the same individuals according to the DNA extraction method used. DNA purity could be responsible for the discrepancy in telomere length but this will require validation studies. We recommend using the same DNA extraction kit when quantifying leukocyte telomere length by qPCR or when comparing different cohorts to avoid erroneous associations between telomere length and traits of interest.

  1. Dorsal Phalloplasty to Preserve Penis Length after Penile Prosthesis Implantation

    Directory of Open Access Journals (Sweden)

    Osama Shaeer

    2017-03-01

    Full Text Available Objectives: Following penile prosthesis implantation (PPI, patients may complain of a decrease in visible penis length. A dorsal phalloplasty defines the penopubic junction by tacking pubic skin to the pubis, revealing the base of the penis. This study aimed to evaluate the efficacy of a dorsal phalloplasty in increasing the visible penis length following PPI. Methods: An inflatable penile prosthesis was implanted in 13 patients with severe erectile dysfunction (ED at the Kamal Shaeer Hospital, Cairo, Egypt, from January 2013 to May 2014. During the surgery, nonabsorbable tacking sutures were used to pin the pubic skin to the pubis through the same penoscrotal incision. Intraoperative penis length was measured before and after the dorsal phalloplasty. Overall patient satisfaction was measured on a 5-point rating scale and patients were requested to subjectively compare their postoperative penis length with memories of their penis length before the onset of ED. Results: Intraoperatively, the dorsal phalloplasty increased the visible length of the erect penis by an average of 25.6%. The average length before and after tacking was 10.2 ± 2.9 cm and 13.7 ± 2.8 cm, respectively (P <0.002. Postoperatively, seven patients (53.8% reported a longer penis, five patients (38.5% reported no change in length and one patient (7.7% reported a slightly shorter penis. The mean overall patient satisfaction score was 4.9 ± 0.3. None of the patients developed postoperative complications. Conclusion: A dorsal phalloplasty during PPI is an effective method of increasing visible penis length, therefore minimising the impression of a shorter penis after implantation.

  2. Leg Length Versus Torso Length in Pedophilia: Further Evidence of Atypical Physical Development Early in Life.

    Science.gov (United States)

    Fazio, Rachel L; Dyshniku, Fiona; Lykins, Amy D; Cantor, James M

    2017-08-01

    Adult men's height results from an interaction among positive and negative influences, including genetic predisposition, conditions in utero, and influences during early development such as nutritional quality, pathogen exposure, and socioeconomic status. Decreased height, reflected specifically as a decreased leg length, is strongly associated with increased risk of poorer health outcomes. Although prior research has repeatedly shown that pedophiles are shorter than nonpedophiles, the largest study to date relied on self-reported height. In the present study, pedophiles demonstrated reduced measured height and reduced leg length as compared with teleiophiles. Given the prenatal and early childhood origins of height, these findings contribute additional evidence to a biological, developmental origin of pedophilia. In addition, the magnitude of this height difference was substantially larger than that found in children exposed to a variety of early environmental stressors, but similar to that seen in other biologically based neurodevelopmental disorders.

  3. Calculation of the Crack Length for a Pipe Specimen using the Modified Load Ratio Method

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jung Hun; Koo, Jae Mean; Seok, Chang Sung [Sungkyunkwan University, Suwon (Korea, Republic of); Huh, Yong; Park, Jae Sil [Samsung Electronics Co., Suwon (Korea, Republic of)

    2009-12-15

    The objective of this paper is to apply the load ratio method to the measurement of the crack length of the real scale pipe specimen. The load ratio method was modified and finite element analyses were performed to derive the relationship between the normalized compliance and the normalized crack length for the pipe specimen. In order to measure the crack length, the direct current potential drop method and the modified load ratio method were applied to the pipe test. The applicability of the modified load ratio method was confirmed by comparing the calculated crack length with the measured crack length from the pipe experiment.

  4. Calculation of the Crack Length for a Pipe Specimen using the Modified Load Ratio Method

    International Nuclear Information System (INIS)

    Choi, Jung Hun; Koo, Jae Mean; Seok, Chang Sung; Huh, Yong; Park, Jae Sil

    2009-01-01

    The objective of this paper is to apply the load ratio method to the measurement of the crack length of the real scale pipe specimen. The load ratio method was modified and finite element analyses were performed to derive the relationship between the normalized compliance and the normalized crack length for the pipe specimen. In order to measure the crack length, the direct current potential drop method and the modified load ratio method were applied to the pipe test. The applicability of the modified load ratio method was confirmed by comparing the calculated crack length with the measured crack length from the pipe experiment

  5. Measuring $\

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, Jessica Sarah [Univ. of Cambridge (United Kingdom)

    2011-01-01

    The MINOS Experiment consists of two steel-scintillator calorimeters, sampling the long baseline NuMI muon neutrino beam. It was designed to make a precise measurement of the ‘atmospheric’ neutrino mixing parameters, Δm2 atm. and sin2 (2 atm.). The Near Detector measures the initial spectrum of the neutrino beam 1km from the production target, and the Far Detector, at a distance of 735 km, measures the impact of oscillations in the neutrino energy spectrum. Work performed to validate the quality of the data collected by the Near Detector is presented as part of this thesis. This thesis primarily details the results of a vμ disappearance analysis, and presents a new sophisticated fitting software framework, which employs a maximum likelihood method to extract the best fit oscillation parameters. The software is entirely decoupled from the extrapolation procedure between the detectors, and is capable of fitting multiple event samples (defined by the selections applied) in parallel, and any combination of energy dependent and independent sources of systematic error. Two techniques to improve the sensitivity of the oscillation measurement were also developed. The inclusion of information on the energy resolution of the neutrino events results in a significant improvement in the allowed region for the oscillation parameters. The degree to which sin2 (2θ )= 1.0 could be disfavoured with the exposure of the current dataset if the true mixing angle was non-maximal, was also investigated, with an improved neutrino energy reconstruction for very low energy events. The best fit oscillation parameters, obtained by the fitting software and incorporating resolution information were: | Δm2| = 2.32+0.12 -0.08×10-3 eV2 and sin2 (2θ ) > 0.90(90% C.L.). The analysis provides the current world best measurement of the atmospheric neutrino mass

  6. Musculoskeletal pain and posture decrease step length in young adults

    Directory of Open Access Journals (Sweden)

    Maria Regina Rachmawati

    2016-02-01

    Full Text Available Pain of the musculoskeletal system, especially low back pain, is one of the most frequent problems with a high risk of disability. The aim of this research study was to determine the existence of an association between low back pain on one hand,  posture and step length on the other. This cross-sectional study was conducted on 77 healthy young adult subjects. Step length was measured with the Biodex Gait Trainer 2 (230 VAC. The study results indicate that 62.3% of the young adult subjects had suffered from low back pain. There was no significant association between gender and pain. In male subjects no significant association was found between pain on one hand and mean difference in step length and posture on the other. However, in female subjects with abnormal posture, there was a highly significant difference in left step length between subjects with back pain and those without (p=0.007.  The results of a multiple regression analysis indicate that posture has the greatest influence on left step length (B=4.135; 95% Confidence Interval 0.292-7.977. It is recommended that in the examination of low back pain an assessment be made of posture, step length and difference in step lengths.

  7. Musculoskeletal pain and posture decrease step length in young adults

    Directory of Open Access Journals (Sweden)

    Maria Regina Rachmawati

    2009-08-01

    Full Text Available Pain of the musculoskeletal system, especially low back pain, is one of the most frequent problems with a high risk of disability. The aim of this research study was to determine the existence of an association between low back pain on one hand, posture and step length on the other. This cross-sectional study was conducted on 77 healthy young adult subjects. Step length was measured with the Biodex Gait Trainer 2 (230 VAC. The study results indicate that 62.3% of the young adult subjects had suffered from low back pain. There was no significant association between gender and pain. In male subjects no significant association was found between pain on one hand and mean difference in step length and posture on the other. However, in female subjects with abnormal posture, there was a highly significant difference in left step length between subjects with back pain and those without (p=0.007. The results of a multiple regression analysis indicate that posture has the greatest influence on left step length (B=4.135; 95% Confidence Interval 0.292-7.977. It is recommended that in the examination of low back pain an assessment be made of posture, step length and difference in step lengths.

  8. String matching with variable length gaps

    DEFF Research Database (Denmark)

    Bille, Philip; Gørtz, Inge Li; Vildhøj, Hjalte Wedel

    2012-01-01

    We consider string matching with variable length gaps. Given a string T and a pattern P consisting of strings separated by variable length gaps (arbitrary strings of length in a specified range), the problem is to find all ending positions of substrings in T that match P. This problem is a basic...

  9. Short Telomere Length and Ischemic Heart Disease

    DEFF Research Database (Denmark)

    Madrid, Alexander Scheller; Rode, Line; Nordestgaard, Børge Grønne

    2016-01-01

    BACKGROUND: Short telomeres are associated with aging and have been associated with a high risk of ischemic heart disease in observational studies; however, the latter association could be due to residual confounding and/or reverse causation. We wanted to test the hypothesis that short telomeres...... are associated with high risk of ischemic heart disease using a Mendelian randomization approach free of reverse causation and of most confounding. METHODS: We genotyped 3 genetic variants in OBFC1 (oligonucleotide/oligosaccharide binding fold containing 1), TERT (telomerase reverse transcriptase), and TERC...... (telomerase RNA component), which code for proteins and RNA involved in telomere maintenance. We studied 105 055 individuals from Copenhagen; 17 235 of these individuals were diagnosed with ischemic heart disease between 1977 and 2013, and 66 618 had telomere length measured. For genetic studies, we further...

  10. Television Watching and Telomere Length Among Adults in Southwest China.

    Science.gov (United States)

    Xue, Hong-Mei; Liu, Qian-Qian; Tian, Guo; Quan, Li-Ming; Zhao, Yong; Cheng, Guo

    2017-09-01

    To explore the independent associations of sedentary behavior and physical activity with telomere length among Chinese adults. Data on total time of sedentary behavior, screen-based sedentary behavior (including television watching and computer or phone use), moderate to vigorous physical activity, and dietary intake of 518 adults in Chengdu, Guizhou, and Xiamen in China (54.25% women) aged 20 to 70 years were obtained between 2013 and 2015 through questionnaires. Height, weight, and waist circumference were measured to calculate body mass index and percentage of body fat. Telomere length was measured through Southern blot technique. Television watching was inversely related to adjusted telomere length (-71.75 base pair; SE = 34.40; P  = .04). Furthermore, a similar trend between telomere length and television watching was found in the group aged 20 to 40 years after adjusting for all covariates. Adults aged 20 to 40 years in the highest tertile of daily time spent on watching television had 4.0% shorter telomere length than adults in the lowest tertile (P = .03). Although the association is modest, television watching is inversely related to telomere length among Chinese adults, warranting further investigation in large prospective studies.

  11. Comparison of a clinical gait analysis method using videography and temporal-distance measures with 16-mm cinematography.

    Science.gov (United States)

    Stuberg, W A; Colerick, V L; Blanke, D J; Bruce, W

    1988-08-01

    The purpose of this study was to compare a clinical gait analysis method using videography and temporal-distance measures with 16-mm cinematography in a gait analysis laboratory. Ten children with a diagnosis of cerebral palsy (means age = 8.8 +/- 2.7 years) and 9 healthy children (means age = 8.9 +/- 2.4 years) participated in the study. Stride length, walking velocity, and goniometric measurements of the hip, knee, and ankle were recorded using the two gait analysis methods. A multivariate analysis of variance was used to determine significant differences between the data collected using the two methods. Pearson product-moment correlation coefficients were determined to examine the relationship between the measurements recorded by the two methods. The consistency of performance of the subjects during walking was examined by intraclass correlation coefficients. No significant differences were found between the methods for the variables studied. Pearson product-moment correlation coefficients ranged from .79 to .95, and intraclass coefficients ranged from .89 to .97. The clinical gait analysis method was found to be a valid tool in comparison with 16-mm cinematography for the variables that were studied.

  12. Finite length thermal equilibria of a pure electron plasma column

    International Nuclear Information System (INIS)

    Prasad, S.A.; O'Neil, T.M.

    1979-01-01

    The electrons of a pure electron plasma may be in thermal equilibrium with each other and still be confined by static magnetic and electric fields. Since the electrons make a significant contribution to the electric field, only certain density profiles are consistent with Poisson's equation. The class of such distributions for a finite length cylindrical column is investigated. In the limit where the Debye length is small compared with the dimensions of the column, the density is essentially constant out to some surface of revolution and then falls off abruptly. The falloff in density is a universal function when measured along the local normal to the surface of revolution and scaled in terms of the Debye length. The solution for the shape of the surface of revolution is simplified by passage to the limit of zero Debye length

  13. Sequence-Dependent Persistence Length of Long DNA

    Science.gov (United States)

    Chuang, Hui-Min; Reifenberger, Jeffrey G.; Cao, Han; Dorfman, Kevin D.

    2017-12-01

    Using a high-throughput genome-mapping approach, we obtained circa 50 million measurements of the extension of internal human DNA segments in a 41 nm ×41 nm nanochannel. The underlying DNA sequences, obtained by mapping to the reference human genome, are 2.5-393 kilobase pairs long and contain percent GC contents between 32.5% and 60%. Using Odijk's theory for a channel-confined wormlike chain, these data reveal that the DNA persistence length increases by almost 20% as the percent GC content increases. The increased persistence length is rationalized by a model, containing no adjustable parameters, that treats the DNA as a statistical terpolymer with a sequence-dependent intrinsic persistence length and a sequence-independent electrostatic persistence length.

  14. Telomere Length – a New Biomarker in Medicine

    Directory of Open Access Journals (Sweden)

    Agnieszka Kozłowska

    2015-12-01

    Full Text Available A number of xenobiotics in the environment and workplace influences on our health and life. Biomarkers are tools for measuring such exposures and their effects in the organism. Nowadays, telomere length, epigenetic changes, mutations and changes in gene expression pattern have become new molecular biomarkers. Telomeres play the role of molecular clock, which influences on expectancy of cell life and thus aging, the formation of damages, development diseases and carcinogenesis. The telomere length depends on mechanisms of replication and the activity of telomerase. Telomere length is currently used as a biomarker of susceptibility and/or exposure. This paper describes the role of telomere length as a biomarker of aging cells, oxidative stress, a marker of many diseases including cancer, and as a marker of environmental and occupational exposure.

  15. Focal Length Affects Depicted Shape and Perception of Facial Images.

    Directory of Open Access Journals (Sweden)

    Vít Třebický

    Full Text Available Static photographs are currently the most often employed stimuli in research on social perception. The method of photograph acquisition might affect the depicted subject's facial appearance and thus also the impression of such stimuli. An important factor influencing the resulting photograph is focal length, as different focal lengths produce various levels of image distortion. Here we tested whether different focal lengths (50, 85, 105 mm affect depicted shape and perception of female and male faces. We collected three portrait photographs of 45 (22 females, 23 males participants under standardized conditions and camera setting varying only in the focal length. Subsequently, the three photographs from each individual were shown on screen in a randomized order using a 3-alternative forced-choice paradigm. The images were judged for attractiveness, dominance, and femininity/masculinity by 369 raters (193 females, 176 males. Facial width-to-height ratio (fWHR was measured from each photograph and overall facial shape was analysed employing geometric morphometric methods (GMM. Our results showed that photographs taken with 50 mm focal length were rated as significantly less feminine/masculine, attractive, and dominant compared to the images taken with longer focal lengths. Further, shorter focal lengths produced faces with smaller fWHR. Subsequent GMM revealed focal length significantly affected overall facial shape of the photographed subjects. Thus methodology of photograph acquisition, focal length in this case, can significantly affect results of studies using photographic stimuli perhaps due to different levels of perspective distortion that influence shapes and proportions of morphological traits.

  16. Effects of preservation method on length and weight of pond raised ...

    African Journals Online (AJOL)

    Length and weight measurements of fish used for taxonomy and determination of length-weight relationship are taken from preserved specimen. This study sets out to investigate the effects of two preservatives, 70% alcohol and 10% formalin and freezing method on the length and weight of preserved specimens of tilapia ...

  17. Patient length of stay and mortality prediction: A survey.

    Science.gov (United States)

    Awad, Aya; Bader-El-Den, Mohamed; McNicholas, James

    2017-05-01

    Over the past few years, there has been increased interest in data mining and machine learning methods to improve hospital performance, in particular hospitals want to improve their intensive care unit statistics by reducing the number of patients dying inside the intensive care unit. Research has focused on prediction of measurable outcomes, including risk of complications, mortality and length of hospital stay. The length of stay is an important metric both for healthcare providers and patients, influenced by numerous factors. In particular, the length of stay in critical care is of great significance, both to patient experience and the cost of care, and is influenced by factors specific to the highly complex environment of the intensive care unit. The length of stay is often used as a surrogate for other outcomes, where those outcomes cannot be measured; for example as a surrogate for hospital or intensive care unit mortality. The length of stay is also a parameter, which has been used to identify the severity of illnesses and healthcare resource utilisation. This paper examines a range of length of stay and mortality prediction applications in acute medicine and the critical care unit. It also focuses on the methods of analysing length of stay and mortality prediction. Moreover, the paper provides a classification and evaluation for the analytical methods of the length of stay and mortality prediction associated with a grouping of relevant research papers published in the years 1984 to 2016 related to the domain of survival analysis. In addition, the paper highlights some of the gaps and challenges of the domain.

  18. Full length prototype SSC dipole test results

    International Nuclear Information System (INIS)

    Strait, J.; Brown, B.C.; Carson, J.

    1987-01-01

    Results are presented from tests of the first full length prototype SSC dipole magnet. The cryogenic behavior of the magnet during a slow cooldown to 4.5K and a slow warmup to room temperature has been measured. Magnetic field quality was measured at currents up to 2000 A. Averaged over the body field all harmonics with the exception of b 2 and b 8 are at or within the tolerances specified by the SSC Central Design Group. (The values of b 2 and b 8 result from known design and construction defects which will be be corrected in later magnets.) Using an NMR probe the average body field strength is measured to be 10.283 G/A with point to point variations on the order of one part in 1000. Data are presented on quench behavior of the magnet up to 3500 A (approximately 55% of full field) including longitudinal and transverse velocities for the first 250 msec of the quench

  19. Sonographic Growth Charts for Kidney Length in Normal Korean Children: a Prospective Observational Study.

    Science.gov (United States)

    Oh, Min-Su; Hwang, Geol; Han, Sanghoon; Kang, Hyun Sik; Kim, Seung Hyo; Kim, Young Don; Kang, Ki-Soo; Shin, Kyung-Sue; Lee, Mu Sook; Choi, Guk Myung; Han, Kyoung Hee

    2016-07-01

    Kidney length is the most useful parameter for clinical measurement of kidney size, and is useful to distinguish acute kidney injury from chronic kidney disease. In this prospective observational study of 437 normal children aged between 0 and kidney length was measured using sonography. There were good correlations between kidney length and somatic values, including age, weight, height, and body surface area. The rapid growth of height during the first 2 years of life was intimately associated with a similar increase in kidney length, suggesting that height should be considered an important factor correlating with kidney length. Based on our findings, the following regression equation for the reference values of bilateral kidney length for Korean children was obtained: kidney length of the right kidney (cm) = 0.051 × height (cm) + 2.102; kidney length of the left kidney (cm) = 0.051 × height (cm) + 2.280. This equation may aid in the diagnosis of various kidney disorders.

  20. Determinants of gap length in esophageal atresia with tracheoesophageal fistula and the impact of gap length on outcome

    Directory of Open Access Journals (Sweden)

    Muffazzal Rassiwala

    2016-01-01

    Full Text Available Aim: This study was aimed at identifying factors which may affect the gap length in cases of esophageal atresia with tracheoesophageal fistula (EA-TEF and whether gap length plays any role in determining the outcome. Materials and Methods: All consecutive cases of EA-TEF were included and different patient parameters were recorded. Plain radiographs with a nasogastric tube in the upper esophagus were taken. Patients were grouped into T1-T2; T2-T3; T3-T4; and T4 depending on the thoracic vertebral level of the arrest of the tube. During surgery, the gap length between the pouches was measured using a Vernier caliper and the patients were grouped into A, B, and C (gap length >2.1 cm; >1-≤2 cm and ≤1 cm. The operative gap groups were compared with the radiography groups and the other recorded parameters. Results: Total numbers of cases were 69. Birth weight was found to be significantly lower in Group A (mean = 2.14 kg as compared to Group B (mean = 2.38 kg and Group C patients (mean = 2.49 kg (P = 0.016. The radiographic groups compared favorably with the intraoperative gap length groups (P < 0.001. The need for postoperative ventilation (70.83% in Group A vs. 36.84% in Group C, P = 0.032 and mortality (62.5%, 26.9% and 15.8% in Group A, B, and C, respectively, P = 0.003 co-related significantly with the gap length. Conclusion: Birth weight had a direct reciprocal relationship with the gap length. Radiographic assessment correlated with intraoperative gap length. Higher gap length was associated with increased need for postoperative ventilation and poor outcome.

  1. Sexual dimorphism of root length on a Greek population sample.

    Science.gov (United States)

    Zorba, E; Vanna, V; Moraitis, K

    2014-04-01

    Sexual dimorphism in teeth has been an area of research for osteoarchaeologists and forensic anthropologists studying human skeletal remains. As most studies have been based on the mesiodistal and buccolingual crown measurements, sexual dimorphism from root length dimensions remains "neglected" by comparison to crown dimensions. The aim of the present study was to test the existence of sexual dimorphism in the root length of single-rooted teeth with the purpose of investigating whether maximum root length can be reliably used to determine sex. A total of 774 permanent teeth in 102 individuals (58 males and 44 females) from the Athens Collection were examined. The maximum root length of each tooth was measured on the mesial, distal, buccal, and lingual side. Almost all teeth presented a high degree of sexual dimorphism with males showing numerically higher values in root length than females. The most dimorphic teeth were the maxillary second incisors followed by maxillary canines. The percentage of sexual dimorphism reached 16.56%, with maxillary teeth showing the highest degree of dimorphism. The classification results show that the overall correctly specified group percentage ranged from 58.6% to 90.0%. The data generated from this study suggest that root length measurements offer a reliable method for determining sex and are therefore useful in osteoarchaeological studies, particularly in cases of fragmented or cremated material, but also in forensic contexts. Moreover, root length can be used to separate the remains of female and male subadult individuals with a high level of accuracy thus addressing one of the most problematic issues in human osteoarchaeology and anthropology as immature skeletons are the most difficult to sex. Copyright © 2013 Elsevier GmbH. All rights reserved.

  2. Father Loss and Child Telomere Length.

    Science.gov (United States)

    Mitchell, Colter; McLanahan, Sara; Schneper, Lisa; Garfinkel, Irv; Brooks-Gunn, Jeanne; Notterman, Daniel

    2017-08-01

    Father loss during childhood has negative health and behavioral consequences, but the biological consequences are unknown. Our goal was to examine how father loss (because of separation and/or divorce, death, or incarceration) is associated with cellular function as estimated by telomere length. Data come from the 9-year follow-up of the Fragile Families and Child Wellbeing Study, a birth cohort study of children in 20 large American cities ( N = 2420). Principal measures are as follows: salivary telomere length (sTL), mother reports of father loss, and polymorphisms in genes related to serotonergic and dopaminergic signaling. At 9 years of age, children with father loss have significantly shorter telomeres (14% reduction). Paternal death has the largest association (16%), followed by incarceration (10%), and separation and/or divorce (6%). Changes in income partially mediate these associations (95% mediation for separation and/or divorce, 30% for incarceration, and 25% for death). Effects are 40% greater for boys and 90% greater for children with the most reactive alleles of the serotonin transporter genes when compared with those with the least reactive alleles. No differences were found by age at father loss or a child's race/ethnicity. Father loss has a significant association with children's sTL, with the death of a father showing the largest effect. Income loss explains most of the association between child sTL and separation and/or divorce but much less of the association with incarceration or death. This underscores the important role of fathers in the care and development of children and supplements evidence of the strong negative effects of parental incarceration. Copyright © 2017 by the American Academy of Pediatrics.

  3. Ocular axial length measurement among normal adults using ...

    African Journals Online (AJOL)

    , as visual compromise is a major consequence if they are not diagnosed and managed appropriately. Aim and Objectives: To use magnetic resonance imaging, to determine the normal AL of the eyeball and to establish the association, if any, ...

  4. On measuring the neutron coherent scattering length with ultrahigh ...

    Indian Academy of Sciences (India)

    of air, dependent on variations in the temperature, pressure and relative humidity, can be larger than that assumed in [4], viz. Naba/N = 9.137(9) × 10−3 fm. This can be eliminated by performing the experiment in vacuum. With a crystalline silicon sample (Nd = 1.57 × 1015 cm−2), our proposed phase ΦI−II = −267816.2◦.

  5. Tagging charm with decay lengths

    International Nuclear Information System (INIS)

    Reay, N.W.

    1982-01-01

    With much detail, the author of this selection discusses two experiments which use the same physics but in different ways to obtain one same goala background - free sample of charm decays. One of the major purposes of gaining this sample is to measure one lifetime for charmed particles and to locate new particles. Continuing to discuss the first experiment, the Fermilab Experiment + 531, the author describes its methods, philosophy and two unexpected effects of the experiment. He turns then to discuss the CERN NA-15 experiment, describing its methods, findings and difficulties. Concluding his discussion on a positive note, the author is hopeful for the plans to continue more experimentation

  6. Managing carbon sinks by changing rotation length in European forests

    Energy Technology Data Exchange (ETDEWEB)

    Kaipainen, Terhi; Liski, Jari; Pussinen, Ari; Karjalainen, Timo

    2004-06-01

    Elongation of rotation length is a forest management activity countries may choose to apply under Article 3.4 of the Kyoto Protocol to help them meet their commitments for reduction of greenhouse gas emissions. We used the CO2FIX model to analyze how the carbon stocks of trees, soil and wood products depend on rotation length in different European forests. Results predicted that the carbon stock of trees increased in each forest when rotation length was increased, but the carbon stock of soil decreased slightly in German and Finnish Scots pine forests; the carbon stock of wood products also decreased slightly in cases other than the Sitka spruce forest in UK. To estimate the efficiency of increasing rotation length as an Article 3.4 activity, we looked at changes in the carbon stock of trees resulting from a 20-year increase in current rotation lengths. To achieve the largest eligible carbon sink mentioned in Article 3.4 of the Kyoto Protocol, the rotation lengths need to be increased on areas varying from 0.3 to 5.1 Mha depending on the forest. This would in some forests cause 1-6% declines in harvesting possibilities. The possible decreases in the carbon stock of soil indicate that reporting the changes in the carbon stocks of forests under Article 3.4 may require measuring soil carbon.

  7. Lengths and Positions of the Vermiform Appendix among Sudanese Cadavers

    Directory of Open Access Journals (Sweden)

    Ehab I. El-Amin

    2015-08-01

    Full Text Available Background/objective: The anatomy of vermiform appendix displays great variations in length and position between different populations. The reports relating these variations to a specific etiological factor are few. This study aims to describe the positions and lengths of vermiform appendix among Sudanese cadavers. Methods: This descriptive study was carried out in Omdurman Teaching Hospital Morgue and Omdurman Islamic University-Sudan. Sixty Sudanese cadavers (30 male and 30 female, were dissected in the period from June 2013 to June 2014. The positions and the lengths of vermiform appendix were measured in millimeters. The data was analyzed by SPSS version 20. Results: The cadavers’ age ranged between 20 to 80 years according to their medico-legal reports. Retrocaecal position was mainly observed in 60%, pelvic in 35%, post-ileal in 3.3%, and pre-ileal in 1.7%. The lengths of the appendix was found < 69 mm in 23.3%, 70-110 mm in 60%, and > 110 mm in 16.7%, also the study showed insignificant difference between the lengths and ages (p < 0.08, and between males and females (p = 0.23. Age was the influencing factor for the positions of vermiform appendixes (p = 0.04. Conclusion: The study showed that the commonest lengths of the appendix were 70-110 mm while the common position was retrocaecal regardless to age or gender. This data should be considered in surgical removal of the inflamed appendix.

  8. Relation between axial length and ocular parameters

    Directory of Open Access Journals (Sweden)

    Xue-Qiu Yang

    2013-09-01

    Full Text Available AIM: To investigatethe relation between axial length(AL, age and ocular parameters.METHODS: A total of 360 subjects(360 eyeswith emmetropia or myopia were recruited. Refraction, center corneal thickness(CCT, AL, intraocular pressure(IOPwere measured by automatic-refractor, Pachymeter, A-mode ultrasound and non-contact tonometer, respectively. Corneal curvature(CC, anterior chamber depth(ACDand white-to-white distance(WWDwere measured by Orbscan II. Three dimensional frequency domain coherent optical tomography(3D-OCTwas used to examine the retinal nerve fiber layer thickness(RNFLT. The Pearson correlation coefficient(rand multiple regression analysis were performed to evaluate the relationship between AL, age and ocular parameters.RESULTS: The average AL was 24.15±1.26mm. With elongation of the AL, spherical equivalent(SE(r=-0.742,Pr=-0.395, Pr=-0.374, Pr=0.411, Pr=0.099, P=0.060and WWD(r=0.061, P=0.252. There was also a significant correlation between AL and age(P=0.001, SE(PPPCONCLUSION: In longer eyes, there is a tendency toward myopia, a flatter cornea, a deeper ACD and a thinner RNFLT. Age is an influencing factor for the AL as well.

  9. Debye screening length effects of nanostructured materials

    CERN Document Server

    Ghatak, Kamakhya Prasad

    2014-01-01

    This monograph solely investigates the Debye Screening Length (DSL) in semiconductors and their nano-structures. The materials considered are quantized structures of non-linear optical, III-V, II-VI, Ge, Te, Platinum Antimonide, stressed materials, Bismuth, GaP, Gallium Antimonide, II-V and Bismuth Telluride respectively. The DSL in opto-electronic materials and their quantum confined counterparts is studied in the presence of strong light waves and intense electric fields on the basis of newly formulated electron dispersion laws that control the studies of such quantum effect devices. The suggestions for the experimental determination of 2D and 3D DSL and the importance of measurement of band gap in optoelectronic materials under intense built-in electric field in nano devices and strong external photo excitation (for measuring photon induced physical properties) have also been discussed in this context. The influence of crossed electric and quantizing magnetic fields on the DSL and the DSL in heavily doped ...

  10. Short Rayleigh Length Free Electron Lasers

    CERN Document Server

    Crooker, P P; Armstead, R L; Blau, J

    2004-01-01

    Conventional free electron laser (FEL) oscillators minimize the optical mode volume around the electron beam in the undulator by making the resonator Rayleigh length about one third of the undulator length. This maximizes gain and beam-mode coupling. In compact configurations of high-power infrared FELs or moderate power UV FELs, the resulting optical intensity can damage the resonator mirrors. To increase the spot size and thereby reduce the optical intensity at the mirrors below the damage threshold, a shorter Rayleigh length can be used, but the FEL interaction is significantly altered. A new FEL interaction is described and analyzed with a Rayleigh length that is only one tenth the undulator length, or less. The effect of mirror vibration and positioning are more critical in the short Rayleigh length design, but we find that they are still within normal design tolerances.

  11. Radiographic assessment of endodontic working length

    OpenAIRE

    Osama S Alothmani; Lara T Friedlander; Nicholas P Chandler

    2013-01-01

    The use of radiographs for working length determination is usual practice in endodontics. Exposing radiographs following the principles of the paralleling technique allows more accurate length determination compared to the bisecting-angle method. However, it has been reported that up to 28.5% of cases can have the file tip extending beyond the confines of the root canals despite an acceptable radiographic appearance. The accuracy of radiographic working length determination could be affected ...

  12. Information, polarization and term length in democracy

    DEFF Research Database (Denmark)

    Schultz, Christian

    2008-01-01

    accountable, but the re-election incentive leads to policy-distortion as the government seeks to manipulate swing voters' beliefs to make its ideology more popular. This creates a trade-off: A short term length improves accountability but gives distortions. A short term length is best for swing voters when......This paper considers term lengths in a representative democracy where the political issue divides the population on the left-right scale. Parties are ideologically different and better informed about the consequences of policies than voters are. A short term length makes the government more...

  13. Comparative analysis of maximum renal longitudinal length with positional changes on ultrasound with multiplanar reconstructed MR image in Korea Adults

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Yun Hee; Cho, Bum Sang; Kang, Min Ho; Kang, Woo Young; Lee, Jisun; Kim, Yook; Lee, Soo Hyun; Lee, Soo Jung [Dept. of Radiology, Chungbuk National University Hospital, Cheongju (Korea, Republic of); Lee, Jin Yong [Public Health Medical Service, Seoul National University Boramae Medical Center, Seoul (Korea, Republic of)

    2016-07-15

    The purpose of this study was to determine a suitable position in which the measured length on ultrasound is close to the true renal length obtained through a multiplanar reconstructed MR image. A total of 33 individuals (males: 15, females: 18) without any underlying renal disease were included in the present study. Renal length was measured as the longest axis at the level of the renal hilum in three positions-supine, lateral decubitus, and prone, respectively. With a 3.0 T MR scanner, 3D eTHRIVE was acquired. Subsequently, the maximum longitudinal length of both the kidneys was measured through multiplanar reconstructed MR images. Paired t-test was used to compare the renal length obtained from ultrasonographic measurement with the length obtained through multiplanar reconstructed MR images. Our study demonstrated significant difference between sonographic renal length in three positions and renal length through MRI (p < 0.001). However, the longest longitudinal length of right kidney among the measured three values by ultrasound was statistically similar to the renal length measured by reconstructed MR image. Among them, the lateral decubitus position showed the strongest correlation with true renal length (right: 0.887; left: 0.849). We recommend measurement of the maximum renal longitudinal length in all possible positions on ultrasonography. If not allowed, the best measurement is on the lateral decubitus showing the strongest correlation coefficient with true renal length.

  14. Romantic Relationship Development: The Interplay between Age and Relationship Length

    Science.gov (United States)

    Lantagne, Ann; Furman, Wyndol

    2017-01-01

    The present study explored how romantic relationship qualities develop with age and relationship length. Eight waves of data on romantic relationships were collected over 10.5 years during adolescence and early adulthood from a community-based sample in a Western U.S. city (100 males, 100 females; M age Wave 1 = 15.83). Measures of support,…

  15. Length-weight relationships of fishes from South African estuaries

    CSIR Research Space (South Africa)

    Harrison, TD

    2001-02-01

    Full Text Available in the ?eld, measured to the nearest mm SL and weighed to the nearest 1.0g using a Bonso model 323 balance (Bonso Electronics Intl, Hong Kong). The length?weight relationships of all species collected were determined by the expression w ? alb, where w...

  16. Calculating Mean Length of Utterance for Eastern Canadian Inuktitut

    Science.gov (United States)

    Allen, Shanley E. M.; Dench, Catherine

    2015-01-01

    Although virtually all Inuit children in eastern Arctic Canada learn Inuktitut as their native language, there is a critical lack of tools to assess their level of language ability. This article investigates how mean length of utterance (MLU), a widely-used assessment measure in English and other languages, can be best applied in Inuktitut. The…

  17. Sonographic Evaluation of the Splenic Length in Normal Pregnancy ...

    African Journals Online (AJOL)

    Methods: A prospective descriptive cross sectional study of the sonographic measurements of the splenic length was performed on 150 healthy normal pregnant women correlating this with the body mass index, gestational age and parity. Data were analyzed using software SPSS version 15 (SPSS Inc., Chicago, IL, USA).

  18. Stature prediction from foot length in a Nigerian population | Iheanyi ...

    African Journals Online (AJOL)

    This study is aimed at establishing the reliability of estimating stature from foot length measurement in a Nigerian population. Two hundred and sixty-two healthy medical students of Imo State University Owerri, Nigeria were used for the study. The study yielded positive correlation coefficients of 0.698 and 0.70 for males and ...

  19. Specific root length as an indicator of environmental change

    NARCIS (Netherlands)

    Ostonen, I.; Püttsepp, Ü.; Biel, C.; Alberton, O.; Bakker, M.R.; Löhmus, K.; Majdi, H.; Metcalfe, J.D.; Olsthoorn, A.F.M.; Pronk, A.A.; Vanguelova, E.; Weih, M.; Brunner, I.

    2007-01-01

    Specific root length (SRL, m g-1) is probably the most frequently measured morphological parameter of fine roots. It is believed to characterize economic aspects of the root system and to be indicative of environmental changes. The main objectives of this paper were to review and summarize the

  20. Development of Oscillating Classifiers for Forage Chop Length ...

    African Journals Online (AJOL)

    The only reliable method being tedious hand measurement of every particle in a sample of chopped material. Three oscillating particle length classifiers have been developed. Each of them differed from one another in their stroke patterns. The three different drive-mechanisms produce three screen motions: Linear motion, ...

  1. Otolith Length-Fish Length Relationships of Eleven US Arctic Fish Species and Their Application to Ice Seal Diet Studies

    Science.gov (United States)

    Walker, K. L.; Norcross, B.

    2016-02-01

    The Arctic ecosystem has moved into the spotlight of scientific research in recent years due to increased climate change and oil and gas exploration. Arctic fishes and Arctic marine mammals represent key parts of this ecosystem, with fish being a common part of ice seal diets in the Arctic. Determining sizes of fish consumed by ice seals is difficult because otoliths are often the only part left of the fish after digestion. Otolith length is known to be positively related to fish length. By developing species-specific otolith-body morphometric relationships for Arctic marine fishes, fish length can be determined for fish prey found in seal stomachs. Fish were collected during ice free months in the Beaufort and Chukchi seas 2009 - 2014, and the most prevalent species captured were chosen for analysis. Otoliths from eleven fish species from seven families were measured. All species had strong linear relationships between otolith length and fish total length. Nine species had coefficient of determination values over 0.75, indicating that most of the variability in the otolith to fish length relationship was explained by the linear regression. These relationships will be applied to otoliths found in stomachs of three species of ice seals (spotted Phoca largha, ringed Pusa hispida, and bearded Erignathus barbatus) and used to estimate fish total length at time of consumption. Fish lengths can in turn be used to calculate fish weight, enabling further investigation into ice seal energetic demands. This application will aid in understanding how ice seals interact with fish communities in the US Arctic and directly contribute to diet comparisons among and within ice seal species. A better understanding of predator-prey interactions in the US Arctic will aid in predicting how ice seal and fish species will adapt to a changing Arctic.

  2. Measure for measure

    Science.gov (United States)

    Weinberger, Peter

    2012-06-01

    The present system of measures for length, weight and capacity (volume) originates from scientific ideas expressed during the French Revolution in 1789. The history of a compatible unit of length, however, turns out to be less of a scientific but rather of a political character. Here reports to the Philosophical Magazine made in the first quarter of the nineteenth century are used to trace the cultural split between meters and inches, and between kilograms and pounds, that can be experienced in many parts of the world.

  3. Test-retest reliability of spatial and temporal gait parameters in children with cerebral palsy as measured by an electronic walkway.

    Science.gov (United States)

    Sorsdahl, Anne Brit; Moe-Nilssen, Rolf; Strand, Liv Inger

    2008-01-01

    The purpose of this study was to examine test-retest reliability of seven selected temporal and spatial gait parameters and asymmetry measures in children with cerebral palsy. Seventeen children with CP between 3 and 13 years of age walked at three different speeds across an electronic walkway of 5.2m. The tests were repeated after approximately 25 min. The scores were normalized to a walking speed of 1.1m/s to avoid the confounding effect of gait speed on speed dependent gait parameters. Intraclass correlation coefficients (ICC(1,1) and ICC(3,1)) with 95% confidence intervals, within-subject standard deviation (S(w)) and smallest detectable difference (SDD) were calculated. The relative reliability of cadence, step length, stride length and single stance time was high to excellent (ICC(1,1) between 0.73 and 0.95), while it was poor for step width (ICC(1,1)=0.27 and 0.35). The relative reliability for two calculated asymmetry measures were high for the step length index (ICC(1,1)=0.82) and moderate for the single stance time index (ICC(1,1)=0.49). The absolute reliability values for all gait parameters are reported. Five of seven gait parameters measured by an electronic walkway and normalized to a common walking speed, appear to be highly repeatable in a short-term time span in children with CP who were able to walk without assistive walking devices, provided sufficient cognitive function.

  4. Estimation of ocular volume from axial length.

    Science.gov (United States)

    Nagra, Manbir; Gilmartin, Bernard; Logan, Nicola S

    2014-12-01

    To determine which biometric parameters provide optimum predictive power for ocular volume. Sixty-seven adult subjects were scanned with a Siemens 3-T MRI scanner. Mean spherical error (MSE) (D) was measured with a Shin-Nippon autorefractor and a Zeiss IOLMaster used to measure (mm) axial length (AL), anterior chamber depth (ACD) and corneal radius (CR). Total ocular volume (TOV) was calculated from T2-weighted MRIs (voxel size 1.0 mm(3)) using an automatic voxel counting and shading algorithm. Each MR slice was subsequently edited manually in the axial, sagittal and coronal plane, the latter enabling location of the posterior pole of the crystalline lens and partitioning of TOV into anterior (AV) and posterior volume (PV) regions. Mean values (±SD) for MSE (D), AL (mm), ACD (mm) and CR (mm) were -2.62±3.83, 24.51±1.47, 3.55±0.34 and 7.75±0.28, respectively. Mean values (±SD) for TOV, AV and PV (mm(3)) were 8168.21±1141.86, 1099.40±139.24 and 7068.82±1134.05, respectively. TOV showed significant correlation with MSE, AL, PV (all p<0.001), CR (p=0.043) and ACD (p=0.024). Bar CR, the correlations were shown to be wholly attributable to variation in PV. Multiple linear regression indicated that the combination of AL and CR provided optimum R(2) values of 79.4% for TOV. Clinically useful estimations of ocular volume can be obtained from measurement of AL and CR. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. Stature estimation from hand and phalanges lengths of Egyptians.

    Science.gov (United States)

    Habib, Sahar Refaat; Kamal, Nashwa Nabil

    2010-04-01

    Estimation of stature from extremities plays an important role in identifying the deceased in forensic examinations. This study examines the relationship between stature and hand and phalanges lengths among Egyptians. Stature, hand and phalanges lengths of 159 subjects, 82 males and 77 females (18-25years) were measured. Statistical analysis indicated that bilateral variation was insignificant for all measurements. Sex differences were significant for all measurements. Linear and multiple regression equations for stature estimation were calculated. Correlation coefficients were found to be positive, but little finger measurements of male and distal phalanges of female fingers were not correlated with stature. Regression equations were checked for accuracy by comparing the estimated stature and actual stature.

  6. Calcaneotalar ratio: a new concept in the estimation of the length of the calcaneus.

    Science.gov (United States)

    David, Vikram; Stephens, Terry J; Kindl, Radek; Ang, Andy; Tay, Wei-Han; Asaid, Rafik; McCullough, Keith

    2015-01-01

    Maintaining the calcaneal length after calcaneal fractures is vital to restoring the normal biomechanics of the foot, because it acts as an important lever arm to the plantarflexors of the foot. However, estimation of the length of the calcaneus to be reconstructed in comminuted calcaneal fractures can be difficult. We propose a new method to reliably estimate the calcaneal length radiographically by defining the calcaneotalar length ratio. A total of 100 ankle radiographs with no fracture in the calcaneus or talus taken in skeletally mature patients were reviewed by 6 observers. The anteroposterior lengths of the calcaneus and talus were measured, and the calcaneotalar length ratio was determined. The ratio was then used to estimate the length of the calcaneus. Interobserver reliability was determined using Cronbach's α coefficient and Pearson's correlation coefficient. The mean length of the calcaneus was 75 ± 0.6 mm, and the mean length of the talus was 59 ± 0.5 mm. The calcaneotalar ratio was 1.3. Using this ratio and multiplying it by the talar length, the mean average estimated length of the calcaneus was within 0.7 mm of the known calcaneal length. Cronbach's α coefficient and Pearson's correlation coefficient showed excellent interobserver reliability. The proposed calcaneotalar ratio is a new and reliable method to radiographically estimate the normal length of the calcaneus when reconstructing the calcaneus. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Cephalometric assessment of maxillary length in Serbian children with skeletal class III.

    Science.gov (United States)

    Stojanović, Zdenka; Nikolić, Predrag; Nikodijević, Angelina; Milić, Jasmina; Stojanović, Branislav

    2013-07-01

    Malocclusion of skeletal class III is a complex irregularity of sagittal inter-jaw relationship, which is due to irregularities of sagittal position of one or both of the jaw bones, which is often associated with disproportionate ratio of their length. The aim of this study was to determine whether the length of the jaw of children with skeletal class III in the period of mixed dentition was changed. Fifty children with skeletal class III and the same number of those with skeletal class I, of both sexes, have been selected on the basis of cephalometric analysis of profile tele-x-ray of the head. All the children aged 6-12 had mixed dentition, and were divided according to sex and age into three subgroups within each group. The length of maxilla, mandible and cranial base were measured. Proportions among the lengths measured within each group were found and difference significance in the measured lengths and their proportions among groups and subgroups were evaluated. The children with skeletal class III, compared with the findings in the control group, had significantly lower values of maxillary length, total maxillary length, as well as lower values of their lengths in proportion to lengths of the front or the total length of cranial base and in proportion to mandibular lengths (p children with skeletal class III have significantly shorter maxilla than those with skeletal class I.

  8. 7 CFR 29.3037 - Length.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Length. 29.3037 Section 29.3037 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing.... Length, as an element of quality, does not apply to tobacco in strip form. (See Elements of quality.) [24...

  9. Local gauge invariant QED with fundamental length

    International Nuclear Information System (INIS)

    Kadyshevsky, V.G.; Mateev, M.D.

    1981-01-01

    A local gauge theory of electromagnetic interactions with the fundamental length l as a new universal scale is worked out. The Lagrangian contains new extra terms in which the coupling constant is proportional to the fundamental length. The theory has an elegant geometrical basis: in momentum representation one faces de Sitter momentum space with curvature radius 1/l [ru

  10. On the homology length spectrum of surfaces

    OpenAIRE

    Massart, Daniel; Parlier, Hugo

    2014-01-01

    On a surface with a Finsler metric, we investigate the asymptotic growth of the number of closed geodesics of length less than L which minimize length among all geodesic multicurves in the same homology class. An important class of surfaces which are of interest to us are hyperbolic surfaces.

  11. Paternal age and telomere length in twins

    DEFF Research Database (Denmark)

    Hjelmborg, Jacob B; Dalgård, Christine; Mangino, Massimo

    2015-01-01

    Telomere length, a highly heritable trait, is longer in offspring of older fathers. This perplexing feature has been attributed to the longer telomeres in sperm of older men and it might be an 'epigenetic' mechanism through which paternal age plays a role in telomere length regulation in humans...

  12. Influence of mandibular length on mouth opening

    NARCIS (Netherlands)

    Dijkstra, PU; Hof, AL; Stegenga, B; De Bont, LGM

    Theoretically, mouth opening not only reflects the mobility of the temporomandibular joints (TMJs) but also the mandibular length. Clinically, the exact relationship between mouth opening, mandibular length, and mobility of TMJs is unclear. To study this relationship 91 healthy subjects, 59 women

  13. Sonographic Growth Charts for Kidney Length in Normal Korean Children: a Prospective Observational Study

    OpenAIRE

    Oh, Min-su; Hwang, Geol; Han, Sanghoon; Kang, Hyun Sik; Kim, Seung Hyo; Kim, Young Don; Kang, Ki-Soo; Shin, Kyung-Sue; Lee, Mu Sook; Choi, Guk Myung; Han, Kyoung Hee

    2016-01-01

    Kidney length is the most useful parameter for clinical measurement of kidney size, and is useful to distinguish acute kidney injury from chronic kidney disease. In this prospective observational study of 437 normal children aged between 0 and < 13 years, kidney length was measured using sonography. There were good correlations between kidney length and somatic values, including age, weight, height, and body surface area. The rapid growth of height during the first 2 years of life was intimat...

  14. In vivo sarcomere lengths and sarcomere elongations are not uniform across an intact muscle

    Directory of Open Access Journals (Sweden)

    Eng Kuan eMoo

    2016-05-01

    Full Text Available Sarcomere lengths have been a crucial outcome measure for understanding and explaining basic muscle properties and muscle function. Sarcomere lengths for a given muscle are typically measured at a single spot, often in the mid-belly of the muscle, and at a given muscle length. It is then assumed implicitly that the sarcomere length measured at this single spot represents the sarcomere lengths at other locations within the muscle, and force-length, force-velocity and power-velocity properties of muscles are often implied based on these single sarcomere length measurements. Although intuitively appealing, this assumption is yet to be supported by systematic evidence. The objective of this study was to measure sarcomere lengths at defined locations along and across an intact muscle, at different muscle lengths. Using second harmonic generation imaging technique, sarcomere patterns in passive mouse tibialis anterior (TA were imaged in a non-contact manner at five selected locations (‘proximal’, ‘distal’, ‘middle’, ‘medial’ and ‘lateral’ TA sites and at three different lengths encompassing the anatomical range of motion of the TA. We showed that sarcomere lengths varied substantially within small regions of the muscle and also for different sites across the entire TA. Also, sarcomere elongations with muscle lengthening were non-uniform across the muscle, with the highest sarcomere stretches occurring near the myotendinous junction. We conclude that muscle mechanics derived from sarcomere length measured from a small region of a muscle may not well represent the sarcomere length and associated functional properties of the entire muscle.

  15. Musculoskeletal pain and posture decrease step length in young adults

    OpenAIRE

    Maria Regina Rachmawati; Diana Samara; Purnamawati Tjhin; Magdalena Wartono; Yefta Bastian

    2016-01-01

    Pain of the musculoskeletal system, especially low back pain, is one of the most frequent problems with a high risk of disability. The aim of this research study was to determine the existence of an association between low back pain on one hand, posture and step length on the other. This cross-sectional study was conducted on 77 healthy young adult subjects. Step length was measured with the Biodex Gait Trainer 2 (230 VAC). The study results indicate that 62.3% of the young adult subjects ha...

  16. Estimation of gestational age from gall-bladder length.

    Science.gov (United States)

    Udaykumar, K; Udaykumar, Padmaja; Nagesh, K R

    2016-01-01

    Establishing a precise duration of gestation is vital in situations such as infanticide and criminal abortions. The present study attempted to estimate the gestational age of the foetus from gall-bladder length. Foetuses of various gestational age groups were dissected, and the length of the gall bladder was measured. The results were analysed, and a substantial degree of correlation was statistically confirmed. This novel method is helpful when the foetus is fragmented, putrefied or eviscerated, where this method can be used as an additional parameter to improve the accuracy of foetal age estimation. © The Author(s) 2015.

  17. Determination of thermal neutrons diffusion length in graphite

    International Nuclear Information System (INIS)

    Garcia Fite, J.

    1959-01-01

    The diffusion length of thermal neutrons in graphite using the less possible quantity of material has been determined. The proceeding used was the measurement in a graphite pile which has a punctual source of rapid neutrons inside surrounded by a reflector medium (paraffin or water). The measurement was done in the following conditions: a) introducing an aluminium plate between both materials. b) Introducing a cadmium plate between both materials. (Author) 91 refs

  18. Radiographic assessment of endodontic working length

    Directory of Open Access Journals (Sweden)

    Osama S Alothmani

    2013-01-01

    Full Text Available The use of radiographs for working length determination is usual practice in endodontics. Exposing radiographs following the principles of the paralleling technique allows more accurate length determination compared to the bisecting-angle method. However, it has been reported that up to 28.5% of cases can have the file tip extending beyond the confines of the root canals despite an acceptable radiographic appearance. The accuracy of radiographic working length determination could be affected by the location of the apical foramen, tooth type, canal curvature and superimposition of surrounding structures. Variations among observers by virtue of training and experience may also influence the accuracy of the procedure. The interpretation of radiographs could be affected by film speed and viewing conditions, with the superiority of digital imaging over conventional radiography for working length determination remaining debatable. The combination of several methods is recommended for acquiring the most accurate working length.

  19. Screening length in dusty plasma crystals

    International Nuclear Information System (INIS)

    Nikolaev, V S; Timofeev, A V

    2016-01-01

    Particles interaction and value of the screening length in dusty plasma systems are of great interest in dusty plasma area. Three inter-particle potentials (Debye potential, Gurevich potential and interaction potential in the weakly collisional regime) are used to solve equilibrium equations for two dusty particles suspended in a parabolic trap. The inter-particle distance dependence on screening length, trap parameter and particle charge is obtained. The functional form of inter-particle distance dependence on ion temperature is investigated and compared with experimental data at 200-300 K in order to test used potentials applicability to dusty plasma systems at room temperatures. The preference is given to the Yukawa-type potential including effective values of particle charge and screening length. The estimated effective value of the screening length is 5-15 times larger than the Debye length. (paper)

  20. Assessing Telomere Length Using Surface Enhanced Raman Scattering

    Science.gov (United States)

    Zong, Shenfei; Wang, Zhuyuan; Chen, Hui; Cui, Yiping

    2014-11-01

    Telomere length can provide valuable insight into telomeres and telomerase related diseases, including cancer. Here, we present a brand-new optical telomere length measurement protocol using surface enhanced Raman scattering (SERS). In this protocol, two single strand DNA are used as SERS probes. They are labeled with two different Raman molecules and can specifically hybridize with telomeres and centromere, respectively. First, genome DNA is extracted from cells. Then the telomere and centromere SERS probes are added into the genome DNA. After hybridization with genome DNA, excess SERS probes are removed by magnetic capturing nanoparticles. Finally, the genome DNA with SERS probes attached is dropped onto a SERS substrate and subjected to SERS measurement. Longer telomeres result in more attached telomere probes, thus a stronger SERS signal. Consequently, SERS signal can be used as an indicator of telomere length. Centromere is used as the inner control. By calibrating the SERS intensity of telomere probe with that of the centromere probe, SERS based telomere measurement is realized. This protocol does not require polymerase chain reaction (PCR) or electrophoresis procedures, which greatly simplifies the detection process. We anticipate that this easy-operation and cost-effective protocol is a fine alternative for the assessment of telomere length.