WorldWideScience

Sample records for strict quality control

  1. Synchronizing strict-feedback and general strict-feedback chaotic systems via a single controller

    International Nuclear Information System (INIS)

    Chen Shihua; Wang Feng; Wang Changping

    2004-01-01

    We present a systematic design procedure to synchronize a class of chaotic systems in a so-called strict-feedback form based on back-stepping procedure. This approach needs only a single controller to realize synchronization no matter how many dimensions the chaotic system contains. Furthermore, we point out that the method does not work for general strict-feedback chaotic systems, for instance, Lorenz system. Therefore, we propose three kinds of synchronization schemes for Lorenz system using the Lyapunov function method. All the three schemes avoid including divergence factor as in Ref. [Chaos, Solitons and Fractals 16 (2003) 37]. Especially in the last two schemes, we need only one state variable in controller, which has important significance in chaos synchronization used for communication purposes. Finally numerical simulations are provided to show the effectiveness and feasibility of the developed methods

  2. Strict integrity control of biomedical images

    Science.gov (United States)

    Coatrieux, Gouenou; Maitre, Henri; Sankur, Bulent

    2001-08-01

    The control of the integrity and authentication of medical images is becoming ever more important within the Medical Information Systems (MIS). The intra- and interhospital exchange of images, such as in the PACS (Picture Archiving and Communication Systems), and the ease of copying, manipulation and distribution of images have brought forth the security aspects. In this paper we focus on the role of watermarking for MIS security and address the problem of integrity control of medical images. We discuss alternative schemes to extract verification signatures and compare their tamper detection performance.

  3. Detection of low numbers of microplastics in North Sea fish using strict quality assurance criteria

    NARCIS (Netherlands)

    Hermsen, E.; Pompe, R.; Besseling, E.; Koelmans, A.A.

    2017-01-01

    We investigated 400 individual fish of four North Sea species: Atlantic Herring, Sprat, Common Dab, and Whiting on ingestion of > 20 μm microplastic. Strict quality assurance criteria were followed in order to control contamination during the study. Two plastic particles were found in only 1 (a

  4. Detection of low numbers of microplastics in North Sea fish using strict quality assurance criteria.

    Science.gov (United States)

    Hermsen, Enya; Pompe, Renske; Besseling, Ellen; Koelmans, Albert A

    2017-09-15

    We investigated 400 individual fish of four North Sea species: Atlantic Herring, Sprat, Common Dab, and Whiting on ingestion of >20μm microplastic. Strict quality assurance criteria were followed in order to control contamination during the study. Two plastic particles were found in only 1 (a Sprat) out of 400 individuals (0.25%, with a 95% confidence interval of 0.09-1.1%). The particles were identified to consist of polymethylmethacrylate (PMMA) through FTIR spectroscopy. No contamination occurred during the study, showing the method applied to be suitable for microplastic ingestion studies in biota. We discuss the low particle count for North Sea fish with those in other studies and suggest a relation between reported particle count and degree of quality assurance applied. Microplastic ingestion by fish may be less common than thought initially, with low incidence shown in this study, and other studies adhering to strict quality assurance criteria. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Strategy and Aspects of Monitoring / Control Strictly in Coordinated Subsystems

    Directory of Open Access Journals (Sweden)

    William José Borges

    2012-06-01

    Full Text Available This paper aims to discuss the approach structures of the strictly coordinated theoretical framework developed by Zylbersztajn and Farina (1999 as an expanded perspective of the firm, taking into account the food supply chains as an extension of the nexus of contracts proposed by Coase (1937 and taken up by Williamson (1985. The structures stand out as strictly coordinated. Zylbersztajn and Farina (1999 turn to identifying points of common interests that encourage firms to promote contracts between themselves in a strictly coordinated way, considering the degree of asset specificity involved in the transaction and the competitive forces that determine the search for strategic positioning organizations to achieve sustainable superior results.

  6. Synchronization control of cross-strict feedback hyperchaotic system based on cross active backstepping design

    International Nuclear Information System (INIS)

    Wang Jing; Gao Jinfeng; Ma Xikui

    2007-01-01

    This Letter presents a novel cross active backstepping design method for synchronization control of cross-strict feedback hyperchaotic system, in which the ordinary backstepping design is unavailable. The proposed control method, combining backstepping design and active control approach, extends the application of backstepping technique in chaos control. Based on this method, different combinations of controllers can be designed to meet the needs of different applications. The proposed method is applied to achieve chaos synchronization of two identical cross-strict feedback hyperchaotic systems. Also it is used to implement synchronization between cross-strict feedback hyperchaotic system and Roessler hyperchaotic system. Numerical examples illustrate the validity of the control method

  7. Rate Control Efficacy in Permanent Atrial Fibrillation : Successful and Failed Strict Rate Control Against a Background of Lenient Rate Control

    NARCIS (Netherlands)

    Groenveld, Hessel F.; Tijssen, Jan G. P.; Crijns, Harry J. G. M.; Van den Berg, Maarten P.; Hillege, Hans L.; Alings, Marco; Van Veldhuisen, Dirk J.; Van Gelder, Isabelle C.

    2013-01-01

    Objectives This study sought to investigate differences in outcome between patients treated with successful strict, failed strict, and lenient rate control. Background The RACE II (Rate Control Efficacy in Permanent Atrial Fibrillation) study showed no difference in outcome between lenient and

  8. Morfofunctional indices of peripheric blood for persons working within the strict radiation control area

    International Nuclear Information System (INIS)

    Nyagu, A.I.; Yukhimuk, L.N.; Egorova, D.M.; Pogontseva, I.M.

    1992-01-01

    The blood of 118 people permanently working within the area of strict radiation control has been investigated. Erythrocyte morphofunctional value has been estimated taking into consideration the erythrocyte morphological index as well as mechanical and osmotic resistivity of erythrocytes. For people permanently working within the area of strict radiation control intensity of signals of EPR for blood paramagnetic centres essentially changes. It proves profound changes in functioning of blood plasma antioxidant system for people working in the area of strict radiation control. For the people permanently working within the area of strict radiation control in peripheric blood growth of echynocytes and spherocytes as well as lowering of mechanical resistivity of erythrocytes is observed. 4 refs.; 1 fig.; 1 tab

  9. ASHP therapeutic position statement on strict glycemic control in patients with diabetes.

    Science.gov (United States)

    2003-11-15

    The deleterious effects of hyperglycemia have been documented from the biochemical to the pathophysiologic level. Given the research findings and the guidelines for glycemic control established by ADA and ACE, ASHP supports and encourages strict glycemic control in all appropriate patients with diabetes mellitus to reduce the progression of chronic complications.

  10. The Preventive Effect of Strict Gun Control Laws on Suicide and Homicide.

    Science.gov (United States)

    Lester, David; Murrell, Mary E.

    1982-01-01

    Examined state gun control laws and used a multidimensional scaling technique to study the relationship of strictness and death rates. Results showed states with stricter laws had lower suicide rates by firearms but higher rates by other means. No effect on homicide was found. (JAC)

  11. The conditions for attaining the greatest degree of system stability with strict generator excitation control

    Energy Technology Data Exchange (ETDEWEB)

    Gruzdev, I.A.; Ekimova, M.M.; Truspekova, G.A.

    1982-01-01

    Expressions are derived for an idealized model of a complex electric power system; these expressions define the greatest level of stability of an electric power system and the optimum combination of stabilization factors with automatic excitation control in a single power system. The possibility of increasing the level of stability of an electric power system with simultaneous strict automatic excitation control of the synychronous generators in several power systems is analyzed.

  12. Frequency effect on p-nitrophenol degradation under conditions of strict acoustic and electric control

    Directory of Open Access Journals (Sweden)

    Chang-ping Zhu

    2011-03-01

    Full Text Available The process of decomposing p-nitrophenol (PNP with power ultrasound requires strict control of acoustic and electric conditions. In this study, the conditions, including acoustic power and acoustic intensity, but not ultrasonic frequency, were controlled strictly at constant levels. The absorbency and the COD concentrations of the samples were measured in order to show the variation of the sample concentration. The results show significant differences in the trend of the solution degradation rate as acoustic power increases after the PNP solution (with a concentration of 114 mg/L and a pH value of 5.4 is irradiated for 60 min with ultrasonic frequencies of 530.8 kHz, 610.6 kHz, 855.0 kHz, and 1 130.0 kHz. The degradation rate of the solution increases with time and acoustic power (acoustic intensity. On the other hand, the degradation rate of the solution is distinctly dependent on frequency when the acoustic power and intensity are strictly controlled and maintained at constant levels. The degradation rate of the PNP solution declines with ultrasonic frequencies of 530.8 kHz, 610.6 kHz, 855.0 kHz, and 1 130.0 kHz; the COD concentration, on the contrary, increase.

  13. Optimal control of nonlinear continuous-time systems in strict-feedback form.

    Science.gov (United States)

    Zargarzadeh, Hassan; Dierks, Travis; Jagannathan, Sarangapani

    2015-10-01

    This paper proposes a novel optimal tracking control scheme for nonlinear continuous-time systems in strict-feedback form with uncertain dynamics. The optimal tracking problem is transformed into an equivalent optimal regulation problem through a feedforward adaptive control input that is generated by modifying the standard backstepping technique. Subsequently, a neural network-based optimal control scheme is introduced to estimate the cost, or value function, over an infinite horizon for the resulting nonlinear continuous-time systems in affine form when the internal dynamics are unknown. The estimated cost function is then used to obtain the optimal feedback control input; therefore, the overall optimal control input for the nonlinear continuous-time system in strict-feedback form includes the feedforward plus the optimal feedback terms. It is shown that the estimated cost function minimizes the Hamilton-Jacobi-Bellman estimation error in a forward-in-time manner without using any value or policy iterations. Finally, optimal output feedback control is introduced through the design of a suitable observer. Lyapunov theory is utilized to show the overall stability of the proposed schemes without requiring an initial admissible controller. Simulation examples are provided to validate the theoretical results.

  14. Control of Petri nets subject to strict temporal constraints using Max-Plus algebra

    Science.gov (United States)

    Tebani, K.; Amari, S.; Kara, R.

    2018-04-01

    In this paper, we treat the control problem of timed discrete event systems under temporal constraints. This type of constraint is very frequent in production systems, transportation network and in networked automation systems. Precisely, we are interested in the validation of strict temporal constraints imposed on the paths in a timed event graph (TEG) by using Max-Plus algebra. Not all the transitions of the considered TEG model are controllable, i.e. only the input transitions are controllable. An analytical approach for computing state feedback controllers is developed. Sufficient condition is given for the existence of causal control laws satisfying the temporal constraints. In the first, a TEG with observable transitions is considered. Then, the proposed approach is extended to the partially observable TEG. The synthesised feedback can be interpreted by places of control connected to the TEG to guarantee the respect of the time constraints. The proposed method is illustrated in the assembly system example.

  15. Learning-Based Adaptive Optimal Tracking Control of Strict-Feedback Nonlinear Systems.

    Science.gov (United States)

    Gao, Weinan; Jiang, Zhong-Ping; Weinan Gao; Zhong-Ping Jiang; Gao, Weinan; Jiang, Zhong-Ping

    2018-06-01

    This paper proposes a novel data-driven control approach to address the problem of adaptive optimal tracking for a class of nonlinear systems taking the strict-feedback form. Adaptive dynamic programming (ADP) and nonlinear output regulation theories are integrated for the first time to compute an adaptive near-optimal tracker without any a priori knowledge of the system dynamics. Fundamentally different from adaptive optimal stabilization problems, the solution to a Hamilton-Jacobi-Bellman (HJB) equation, not necessarily a positive definite function, cannot be approximated through the existing iterative methods. This paper proposes a novel policy iteration technique for solving positive semidefinite HJB equations with rigorous convergence analysis. A two-phase data-driven learning method is developed and implemented online by ADP. The efficacy of the proposed adaptive optimal tracking control methodology is demonstrated via a Van der Pol oscillator with time-varying exogenous signals.

  16. Global neural dynamic surface tracking control of strict-feedback systems with application to hypersonic flight vehicle.

    Science.gov (United States)

    Xu, Bin; Yang, Chenguang; Pan, Yongping

    2015-10-01

    This paper studies both indirect and direct global neural control of strict-feedback systems in the presence of unknown dynamics, using the dynamic surface control (DSC) technique in a novel manner. A new switching mechanism is designed to combine an adaptive neural controller in the neural approximation domain, together with the robust controller that pulls the transient states back into the neural approximation domain from the outside. In comparison with the conventional control techniques, which could only achieve semiglobally uniformly ultimately bounded stability, the proposed control scheme guarantees all the signals in the closed-loop system are globally uniformly ultimately bounded, such that the conventional constraints on initial conditions of the neural control system can be relaxed. The simulation studies of hypersonic flight vehicle (HFV) are performed to demonstrate the effectiveness of the proposed global neural DSC design.

  17. quality control

    International Nuclear Information System (INIS)

    Skujina, A.; Purina, S.; Riekstina, D.

    1999-01-01

    The optimal objects: soils, spruce needles and bracken ferns were found for the environmental monitoring in the regions of possible radioactive contamination - near SalaspiIs nuclear reactor and Ignalina nuclear power plant. The determination of Sr-90 was based on the radiochemical separation of Sr-90 (=Y-90) by HDEHP extraction and counting the Cerenkov radiation. The quality control of the results was carried out. (authors)

  18. Adaptive terminal sliding mode control for hypersonic flight vehicles with strictly lower convex function based nonlinear disturbance observer.

    Science.gov (United States)

    Wu, Yun-Jie; Zuo, Jing-Xing; Sun, Liang-Hua

    2017-11-01

    In this paper, the altitude and velocity tracking control of a generic hypersonic flight vehicle (HFV) is considered. A novel adaptive terminal sliding mode controller (ATSMC) with strictly lower convex function based nonlinear disturbance observer (SDOB) is proposed for the longitudinal dynamics of HFV in presence of both parametric uncertainties and external disturbances. First, for the sake of enhancing the anti-interference capability, SDOB is presented to estimate and compensate the equivalent disturbances by introducing a strictly lower convex function. Next, the SDOB based ATSMC (SDOB-ATSMC) is proposed to guarantee the system outputs track the reference trajectory. Then, stability of the proposed control scheme is analyzed by the Lyapunov function method. Compared with other HFV control approaches, key novelties of SDOB-ATSMC are that a novel SDOB is proposed and drawn into the (virtual) control laws to compensate the disturbances and that several adaptive laws are used to deal with the differential explosion problem. Finally, it is illustrated by the simulation results that the new method exhibits an excellent robustness and a better disturbance rejection performance than the convention approach. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  19. Globally Stable Adaptive Backstepping Neural Network Control for Uncertain Strict-Feedback Systems With Tracking Accuracy Known a Priori.

    Science.gov (United States)

    Chen, Weisheng; Ge, Shuzhi Sam; Wu, Jian; Gong, Maoguo

    2015-09-01

    This paper addresses the problem of globally stable direct adaptive backstepping neural network (NN) tracking control design for a class of uncertain strict-feedback systems under the assumption that the accuracy of the ultimate tracking error is given a priori. In contrast to the classical adaptive backstepping NN control schemes, this paper analyzes the convergence of the tracking error using Barbalat's Lemma via some nonnegative functions rather than the positive-definite Lyapunov functions. Thus, the accuracy of the ultimate tracking error can be determined and adjusted accurately a priori, and the closed-loop system is guaranteed to be globally uniformly ultimately bounded. The main technical novelty is to construct three new n th-order continuously differentiable functions, which are used to design the control law, the virtual control variables, and the adaptive laws. Finally, two simulation examples are given to illustrate the effectiveness and advantages of the proposed control method.

  20. Online Recorded Data-Based Composite Neural Control of Strict-Feedback Systems With Application to Hypersonic Flight Dynamics.

    Science.gov (United States)

    Xu, Bin; Yang, Daipeng; Shi, Zhongke; Pan, Yongping; Chen, Badong; Sun, Fuchun

    2017-09-25

    This paper investigates the online recorded data-based composite neural control of uncertain strict-feedback systems using the backstepping framework. In each step of the virtual control design, neural network (NN) is employed for uncertainty approximation. In previous works, most designs are directly toward system stability ignoring the fact how the NN is working as an approximator. In this paper, to enhance the learning ability, a novel prediction error signal is constructed to provide additional correction information for NN weight update using online recorded data. In this way, the neural approximation precision is highly improved, and the convergence speed can be faster. Furthermore, the sliding mode differentiator is employed to approximate the derivative of the virtual control signal, and thus, the complex analysis of the backstepping design can be avoided. The closed-loop stability is rigorously established, and the boundedness of the tracking error can be guaranteed. Through simulation of hypersonic flight dynamics, the proposed approach exhibits better tracking performance.

  1. Composite Intelligent Learning Control of Strict-Feedback Systems With Disturbance.

    Science.gov (United States)

    Xu, Bin; Sun, Fuchun

    2018-02-01

    This paper addresses the dynamic surface control of uncertain nonlinear systems on the basis of composite intelligent learning and disturbance observer in presence of unknown system nonlinearity and time-varying disturbance. The serial-parallel estimation model with intelligent approximation and disturbance estimation is built to obtain the prediction error and in this way the composite law for weights updating is constructed. The nonlinear disturbance observer is developed using intelligent approximation information while the disturbance estimation is guaranteed to converge to a bounded compact set. The highlight is that different from previous work directly toward asymptotic stability, the transparency of the intelligent approximation and disturbance estimation is included in the control scheme. The uniformly ultimate boundedness stability is analyzed via Lyapunov method. Through simulation verification, the composite intelligent learning with disturbance observer can efficiently estimate the effect caused by system nonlinearity and disturbance while the proposed approach obtains better performance with higher accuracy.

  2. Employee quality, monitoring environment and internal control

    OpenAIRE

    Chunli Liu; Bin Lin; Wei Shu

    2017-01-01

    We investigate the effect of internal control employees (ICEs) on internal control quality. Using special survey data from Chinese listed firms, we find that ICE quality has a significant positive influence on internal control quality. We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal control regulation system (CSOX), have higher institutional ow...

  3. A set-theoretic model reference adaptive control architecture for disturbance rejection and uncertainty suppression with strict performance guarantees

    Science.gov (United States)

    Arabi, Ehsan; Gruenwald, Benjamin C.; Yucelen, Tansel; Nguyen, Nhan T.

    2018-05-01

    Research in adaptive control algorithms for safety-critical applications is primarily motivated by the fact that these algorithms have the capability to suppress the effects of adverse conditions resulting from exogenous disturbances, imperfect dynamical system modelling, degraded modes of operation, and changes in system dynamics. Although government and industry agree on the potential of these algorithms in providing safety and reducing vehicle development costs, a major issue is the inability to achieve a-priori, user-defined performance guarantees with adaptive control algorithms. In this paper, a new model reference adaptive control architecture for uncertain dynamical systems is presented to address disturbance rejection and uncertainty suppression. The proposed framework is predicated on a set-theoretic adaptive controller construction using generalised restricted potential functions.The key feature of this framework allows the system error bound between the state of an uncertain dynamical system and the state of a reference model, which captures a desired closed-loop system performance, to be less than a-priori, user-defined worst-case performance bound, and hence, it has the capability to enforce strict performance guarantees. Examples are provided to demonstrate the efficacy of the proposed set-theoretic model reference adaptive control architecture.

  4. Effect of strict metabolic control on regulation of subcutaneous blood flow in insulin-dependent diabetic patients

    DEFF Research Database (Denmark)

    Kastrup, J; Mathiesen, E R; Saurbrey, Nina

    1987-01-01

    washout technique. Mean arterial blood pressure was reduced by a maximum of 23 mmHg by elevating the limb above heart level and elevated to a maximum of 65 mmHg by head-up tilt; in the latter position venous pressure was kept constantly low by activation of the leg muscle vein pump (heel raising......The effect of 10 weeks of improved metabolic control on the impaired autoregulation of the subcutaneous blood flow was studied at the level of the lateral malleolus in eight long-term insulin-dependent diabetic patients with clinical microangiopathy. Blood flow was measured by the local 133-Xenon......). Improved metabolic control was achieved using either continuous subcutaneous insulin infusion or multiple insulin injections. The blood glucose concentration declined from (median) 12.7 to 6.8 mmol/l and the HbA1C level from 10.1 to 7.5% during strict metabolic control (p less than 0.01 and p less than 0...

  5. Lenient vs. strict rate control in patients with atrial fibrillation and heart failure: a post-hoc analysis of the RACE II study

    NARCIS (Netherlands)

    Mulder, Bart A.; van Veldhuisen, Dirk J.; Crijns, Harry J. G. M.; Tijssen, Jan G. P.; Hillege, Hans L.; Alings, Marco; Rienstra, Michiel; Groenveld, Hessel F.; van den Berg, Maarten P.; van Gelder, Isabelle C.

    2013-01-01

    It is unknown whether lenient rate control is an acceptable strategy in patients with AF and heart failure. We evaluated differences in outcome in patients with AF and heart failure treated with lenient or strict rate control. This post-hoc analysis of the RACE II trial included patients with an

  6. Costs associated with implementation of a strict policy for controlling spread of highly resistant microorganisms in France.

    Science.gov (United States)

    Birgand, Gabriel; Leroy, Christophe; Nerome, Simone; Luong Nguyen, Liem Binh; Lolom, Isabelle; Armand-Lefevre, Laurence; Ciotti, Céline; Lecorre, Bertrand; Marcade, Géraldine; Fihman, Vincent; Nicolas-Chanoine, Marie-Hélène; Pelat, Camille; Perozziello, Anne; Fantin, Bruno; Yazdanpanah, Yazdan; Ricard, Jean-Damien; Lucet, Jean-Christophe

    2016-01-29

    To assess costs associated with implementation of a strict 'search and isolate' strategy for controlling highly drug-resistant organisms (HDRO). Review of data from 2-year prospective surveillance (01/2012 to 12/2013) of HDRO. Three university hospitals located in northern Paris. Episodes were defined as single cases or outbreaks of glycopeptide-resistant enterococci (GRE) or carbapenemase-producing Enterobacteriacae (CPE) colonisation. Costs were related to staff reinforcement, costs of screening cultures, contact precautions and interruption of new admissions. Univariate analysis, along with simple and multiple linear regression analyses, was conducted to determine variables associated with cost of HDRO management. Overall, 41 consecutive episodes were included, 28 single cases and 13 outbreaks. The cost (mean ± SD) associated with management of a single case identified within and/or 48 h after admission was €4443 ± 11,552 and €11,445 ± 15,743, respectively (pcost varied from €14,864 ± 17,734 for an episode with one secondary case (€7432 ± 8867 per case) to €136,525 ± 151,231 (€12,845 ± 5129 per case) when more than one secondary case occurred. In episodes of single cases, contact precautions and microbiological analyses represented 51% and 30% of overall cost, respectively. In outbreaks, cost related to interruption of new admissions represented 77-94% of total costs, and had the greatest financial impact (R(2)=0.98, pcostly measure in an outbreak situation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. Minimal requirements for quality controls in radiotherapy with external beams

    International Nuclear Information System (INIS)

    1999-01-01

    Physical dosimetric guidelines have been developed by the Italian National Institute of Health study group on quality assurance in radiotherapy to define protocols for quality controls in external beam radiotherapy. While the document does not determine strict rules or firm recommendations, it suggests minimal requirements for quality controls necessary to guarantee an adequate degree of accuracy in external beam radiotherapy [it

  8. Employee quality, monitoring environment and internal control

    Directory of Open Access Journals (Sweden)

    Chunli Liu

    2017-03-01

    Full Text Available We investigate the effect of internal control employees (ICEs on internal control quality. Using special survey data from Chinese listed firms, we find that ICE quality has a significant positive influence on internal control quality. We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal control regulation system (CSOX, have higher institutional ownership or attach greater importance to internal control. Our findings suggest that ICEs play an important role in the design and implementation of internal control systems. Our study should be of interest to both top managers who wish to improve corporate internal control quality and regulators who wish to understand the mechanisms of internal control monitoring.

  9. SPECT quality control tests

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.; Abe, R.

    1987-01-01

    Quality control tests of tomographic system composed by a rotatory chamber (CGR Gammatomome T-9000) and a microcomputer are presented. Traditional quality control tests for scintilation chambers and specific tests for tomographic systems are reported. (M.A.C.) [pt

  10. Strict confluent drawing

    NARCIS (Netherlands)

    Eppstein, D.; Holten, D.H.R.; Löffler, M.; Nöllenburg, M.; Speckmann, B.; Verbeek, K.A.B.

    2013-01-01

    We define strict confluent drawing, a form of confluent drawing in which the existence of an edge is indicated by the presence of a smooth path through a system of arcs and junctions (without crossings), and in which such a path, if it exists, must be unique. We prove that it is NP-complete to

  11. Strict confluent drawing

    NARCIS (Netherlands)

    Eppstein, D.; Holten, D.; Löffler, M.; Nöllenburg, M.; Speckmann, B.; Verbeek, K.A.B.

    2016-01-01

    We define strict confluent drawing, a form of confluent drawing in which the existence of an edge is indicated by the presence of a smooth path through a system of arcs and junctions (without crossings), and in which such a path, if it exists, must be unique. We prove that it is NP-complete to

  12. Quine's "Strictly Vegetarian" Analyticity

    NARCIS (Netherlands)

    Decock, L.B.

    2017-01-01

    I analyze Quine’s later writings on analyticity from a linguistic point of view. In Word and Object Quine made room for a “strictly vegetarian” notion of analyticity. In later years, he developed this notion into two more precise notions, which I have coined “stimulus analyticity” and “behaviorist

  13. "Open mesh" or "strictly selected population" recruitment? The experience of the randomized controlled MeMeMe trial

    Directory of Open Access Journals (Sweden)

    Cortellini M

    2017-07-01

    Full Text Available Mauro Cortellini, Franco Berrino, Patrizia Pasanisi Department of Preventive & Predictive Medicine, Foundation IRCCS National Cancer Institute of Milan, Milan, Italy Abstract: Among randomized controlled trials (RCTs, trials for primary prevention require large samples and long follow-up to obtain a high-quality outcome; therefore the recruitment process and the drop-out rates largely dictate the adequacy of the results. We are conducting a Phase III trial on persons with metabolic syndrome to test the hypothesis that comprehensive lifestyle changes and/or metformin treatment prevents age-related chronic diseases (the MeMeMe trial, EudraCT number: 2012-005427-32, also registered on ClinicalTrials.gov [NCT02960711]. Here, we briefly analyze and discuss the reasons which may lead to participants dropping out from trials. In our experience, participants may back out of a trial for different reasons. Drug-induced side effects are certainly the most compelling reason. But what are the other reasons, relating to the participants’ perception of the progress of the trial which led them to withdraw after randomization? What about the time-dependent drop-out rate in primary prevention trials? The primary outcome of this analysis is the point of drop-out from trial, defined as the time from the randomization date to the withdrawal date. Survival functions were non-parametrically estimated using the product-limit estimator. The curves were statistically compared using the log-rank test (P=0.64, not significant. Researchers involved in primary prevention RCTs seem to have to deal with the paradox of the proverbial “short blanket syndrome”. Recruiting only highly motivated candidates might be useful for the smooth progress of the trial but it may lead to a very low enrollment rate. On the other hand, what about enrolling all the eligible subjects without considering their motivation? This might boost the enrollment rate, but it can lead to biased

  14. "Open mesh" or "strictly selected population" recruitment? The experience of the randomized controlled MeMeMe trial.

    Science.gov (United States)

    Cortellini, Mauro; Berrino, Franco; Pasanisi, Patrizia

    2017-01-01

    Among randomized controlled trials (RCTs), trials for primary prevention require large samples and long follow-up to obtain a high-quality outcome; therefore the recruitment process and the drop-out rates largely dictate the adequacy of the results. We are conducting a Phase III trial on persons with metabolic syndrome to test the hypothesis that comprehensive lifestyle changes and/or metformin treatment prevents age-related chronic diseases (the MeMeMe trial, EudraCT number: 2012-005427-32, also registered on ClinicalTrials.gov [NCT02960711]). Here, we briefly analyze and discuss the reasons which may lead to participants dropping out from trials. In our experience, participants may back out of a trial for different reasons. Drug-induced side effects are certainly the most compelling reason. But what are the other reasons, relating to the participants' perception of the progress of the trial which led them to withdraw after randomization? What about the time-dependent drop-out rate in primary prevention trials? The primary outcome of this analysis is the point of drop-out from trial, defined as the time from the randomization date to the withdrawal date. Survival functions were non-parametrically estimated using the product-limit estimator. The curves were statistically compared using the log-rank test ( P =0.64, not significant). Researchers involved in primary prevention RCTs seem to have to deal with the paradox of the proverbial "short blanket syndrome". Recruiting only highly motivated candidates might be useful for the smooth progress of the trial but it may lead to a very low enrollment rate. On the other hand, what about enrolling all the eligible subjects without considering their motivation? This might boost the enrollment rate, but it can lead to biased results on account of large proportions of drop-outs. Our experience suggests that participants do not change their mind depending on the allocation group (intervention or control). There is no single

  15. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Kaden, W.

    1986-01-01

    General preconditions and methods for QA work in the nuclear field are analysed. The application of general QA principles to actual situations is illustrated by examples in the fields of engineering and of the manufacturing of mechanical and electrical components. All QA measures must be fitted to the complexity and relevance of the work steps, which are under consideration. The key to good product quality is the control of working processes. The term 'controlled process' is discussed in detail and examples of feed back systems are given. The main QA measures for the operation of nuclear power plants include the establishment of a Quality Assurance Program, training and qualification of personnel, procurement control, inspection and tests, reviews and audits. These activities are discussed. (orig.)

  16. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    The practice of nuclear diagnostic imaging requires an appropriate quality assurance program to attain high standards of efficiency and reliability. The International Atomic Energy Agency defines the term quality assurance as ''the closeness with which the outcome of a given procedure approaches some ideal, free from all errors and artifacts.'' The term quality control is used in reference to the specific measures taken to ensure that one particular aspect of the procedure is satisfactory. Therefore, quality assurance is a hospital-wide concept that should involve all aspects of clinical practice. Quality control is concerned with the submission of requests for procedures; the scheduling of patients; the preparation and dispensing of radiopharmaceuticals; the protection of patients, staff, and the general public against radiation hazards and accidents caused by radioactive materials or by faulty equipment; the setting up, use, and maintenance of electronic instruments; the methodology of the actual procedures; the analysis and interpretation of data; the reporting of results; and, finally, the keeping of records. The chapter discusses each of these areas

  17. Quality control in radiotherapy

    International Nuclear Information System (INIS)

    Batalla, A.

    2009-01-01

    The authors discuss the modalities and periodicities of internal quality control on radiotherapy installations. They indicate the different concerned systems and the aspects and items to be controlled (patient and personnel security, apparatus mechanical characteristics, beam quality, image quality, isodose and irradiation duration calculation, data transfer). They present the measurement instruments and tools used for the mechanical controls, dose measurement, beam homogeneity and symmetry, anatomic data acquisition systems, and dose distribution and control imagery calculation

  18. Quality Control Applications

    CERN Document Server

    Chorafas, Dimitris N

    2013-01-01

    Quality control is a constant priority in electrical, mechanical, aeronautical, and nuclear engineering – as well as in the vast domain of electronics, from home appliances to computers and telecommunications. Quality Control Applications provides guidance and valuable insight into quality control policies; their methods, their implementation, constant observation and associated technical audits. What has previously been a mostly mathematical topic is translated here for engineers concerned with the practical implementation of quality control. Once the fundamentals of quality control are established, Quality Control Applications goes on to develop this knowledge and explain how to apply it in the most effective way. Techniques are described and supported using relevant, real-life, case studies to provide detail and clarity for those without a mathematical background. Among the many practical examples, two case studies dramatize the importance of quality assurance: A shot-by-shot analysis of the errors made ...

  19. Software product quality control

    CERN Document Server

    Wagner, Stefan

    2013-01-01

    Quality is not a fixed or universal property of software; it depends on the context and goals of its stakeholders. Hence, when you want to develop a high-quality software system, the first step must be a clear and precise specification of quality. Yet even if you get it right and complete, you can be sure that it will become invalid over time. So the only solution is continuous quality control: the steady and explicit evaluation of a product's properties with respect to its updated quality goals.This book guides you in setting up and running continuous quality control in your environment. Star

  20. Checking quality control?

    DEFF Research Database (Denmark)

    Brodersen, Lars

    2005-01-01

    How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?......How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?...

  1. Synthesis of nanoparticles in a flame aerosol reactor with independent and strict control of their size, crystal phase and morphology

    International Nuclear Information System (INIS)

    Jiang Jingkun; Chen, D-R; Biswas, Pratim

    2007-01-01

    A flame aerosol reactor (FLAR) was developed to synthesize nanoparticles with desired properties (crystal phase and size) that could be independently controlled. The methodology was demonstrated for TiO 2 nanoparticles, and this is the first time that large sets of samples with the same size but different crystal phases (six different ratios of anatase to rutile in this work) were synthesized. The degree of TiO 2 nanoparticle agglomeration was determined by comparing the primary particle size distribution measured by scanning electron microscopy (SEM) to the mobility-based particle size distribution measured by online scanning mobility particle spectrometry (SMPS). By controlling the flame aerosol reactor conditions, both spherical unagglomerated particles and highly agglomerated particles were produced. To produce monodisperse nanoparticles, a high throughput multi-stage differential mobility analyser (MDMA) was used in series with the flame aerosol reactor. Nearly monodisperse nanoparticles (geometric standard deviation less than 1.05) could be collected in sufficient mass quantities (of the order of 10 mg) in reasonable time (1 h) that could be used in other studies such as determination of functionality or biological effects as a function of size

  2. Synthesis of nanoparticles in a flame aerosol reactor with independent and strict control of their size, crystal phase and morphology

    Energy Technology Data Exchange (ETDEWEB)

    Jiang Jingkun; Chen, D-R; Biswas, Pratim [Aerosol and Air Quality Research Laboratory, Department of Energy, Environmental and Chemical Engineering, Washington University in St Louis, Campus Box 1180, St Louis, MO 63130 (United States)

    2007-07-18

    A flame aerosol reactor (FLAR) was developed to synthesize nanoparticles with desired properties (crystal phase and size) that could be independently controlled. The methodology was demonstrated for TiO{sub 2} nanoparticles, and this is the first time that large sets of samples with the same size but different crystal phases (six different ratios of anatase to rutile in this work) were synthesized. The degree of TiO{sub 2} nanoparticle agglomeration was determined by comparing the primary particle size distribution measured by scanning electron microscopy (SEM) to the mobility-based particle size distribution measured by online scanning mobility particle spectrometry (SMPS). By controlling the flame aerosol reactor conditions, both spherical unagglomerated particles and highly agglomerated particles were produced. To produce monodisperse nanoparticles, a high throughput multi-stage differential mobility analyser (MDMA) was used in series with the flame aerosol reactor. Nearly monodisperse nanoparticles (geometric standard deviation less than 1.05) could be collected in sufficient mass quantities (of the order of 10 mg) in reasonable time (1 h) that could be used in other studies such as determination of functionality or biological effects as a function of size.

  3. Quality control of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Verdera, E.S.

    1994-01-01

    The quality control of radiopharmaceuticals is based in physics, physics-chemical and biological controls. Between the different controls can be enumerated the following: visual aspect,side, number of particle beams,activity,purity,ph,isotonicity,sterility,radioinmunoessay,toxicity,stability and clinical essay

  4. Quality Control in construction.

    Science.gov (United States)

    1984-01-01

    behavioral scientists. In 1962, Dr. Kaoru Ishikawa gave shape to the form of training which featured intradepartmental groups of ten or so workers seated...and Japanese circles bears closer scrutiny. 4.3.1 Japanese Ingredients of Quality The founder of quality circles, Dr. Kaoru Ishikawa , gives six...around 51 a table; hence the name Quality Control Circle. 4 Dr. 0 Ishikawa was an engineering professor at Tokyo University, and the circles were

  5. Distributed cooperative H∞ optimal tracking control of MIMO nonlinear multi-agent systems in strict-feedback form via adaptive dynamic programming

    Science.gov (United States)

    Luy, N. T.

    2018-04-01

    The design of distributed cooperative H∞ optimal controllers for multi-agent systems is a major challenge when the agents' models are uncertain multi-input and multi-output nonlinear systems in strict-feedback form in the presence of external disturbances. In this paper, first, the distributed cooperative H∞ optimal tracking problem is transformed into controlling the cooperative tracking error dynamics in affine form. Second, control schemes and online algorithms are proposed via adaptive dynamic programming (ADP) and the theory of zero-sum differential graphical games. The schemes use only one neural network (NN) for each agent instead of three from ADP to reduce computational complexity as well as avoid choosing initial NN weights for stabilising controllers. It is shown that despite not using knowledge of cooperative internal dynamics, the proposed algorithms not only approximate values to Nash equilibrium but also guarantee all signals, such as the NN weight approximation errors and the cooperative tracking errors in the closed-loop system, to be uniformly ultimately bounded. Finally, the effectiveness of the proposed method is shown by simulation results of an application to wheeled mobile multi-robot systems.

  6. Quality control of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Kristensen, K.

    1981-01-01

    Quality assurance was introduced in the pharmaceutical field long before it was used in many other areas, and the term quality control has been used in a much broader sense than merely analytical quality control. The term Good Manufacturing Practice (GMP) has been used to describe the system used for producing safe and effective drugs of a uniform quality. GMP has also been used for the industrial production of radiopharmaceuticals. For the preparation and control of radiopharmaceuticals in hospitals a similar system has been named Good Radiopharmacy Practice (GRP). It contains the same elements as GMP but takes into account the special nature of this group of drugs. Data on the assessment of the quality of radiopharmaceuticals in relation to present standards are reviewed. The general conclusion is that the quality of radiopharmaceuticals appears comparable to that of other drugs. It seems possible to establish the production of radiopharmaceuticals, generators and preparation kits in such a way that analytical control of the final product at the hospital may be limited provided the final preparation work is carried out in accordance with GRP principles. The elements of GRP are reviewed. (author)

  7. Quality control of dosemeters

    International Nuclear Information System (INIS)

    Mendes, L.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are acomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintilation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (Author) [pt

  8. Health benefit from decreasing exposure to heavy metals and metalloid after strict pollution control measures near a typical river basin area in China.

    Science.gov (United States)

    Cao, Suzhen; Duan, Xiaoli; Ma, Yingqun; Zhao, Xiuge; Qin, Yanwen; Liu, Yan; Li, Sai; Zheng, Binghui; Wei, Fusheng

    2017-10-01

    The metal(loid) pollution still is a great concern due to the effects from urbanization and industrialization. While, the health risks from the toxic metal(loid)s could decrease if strict pollution control measures were adopted. However, few studies to date investigate the health risks of heavy metal(loid)s in a systematic river basin for the dependent residents, after taking pollution control measures. Thus, the contents of metal(loid)s (Cu, Pb, Zn, Cd, Mn, As) in surface water along a typical river basin were investigated in this study, and the potential non-carcinogenic and carcinogenic health risks posed to the residents were assessed. Although the soluble contents of Cu, Pb, Zn and Cd exceeded the respective thresholds in two sites located downstream the mine area, they were greatly decreased in comparison with previous contamination levels, and the soluble concentrations of all the metal(loid)s were within the relevant thresholds in the sites far away from the mining area. Moreover, the closer to the mining area, the higher the pollution levels of metal(loid)s. The total hazard index for non-carcinogenic risks of metal(loid)s were basically lower than the threshold (1) for the local population. Whereas, although the content of metal(loid)s were low (such as As), they could pose relative higher non-carcinogenic health risks. The result illustrated that pollution levels, toxicity of the contaminants and exposure behavior patterns all could contribute to the potential detrimental health risks. Additionally, the non-carcinogenic and carcinogenic risks from ingestion exposure were ∼2-∼4 orders of magnitude higher than those from dermal contact. The total carcinogenic risks were basically lower than the maximum tolerable levels (1.0 × 10 -4 ), indicating carcinogenic risks from most areas of the river could also be accepted. Among different population groups, heavy metal(loid)s posed relative higher non-carcinogenic and carcinogenic risks to the children in

  9. Quality Management, Quality Assurance and Quality Control in Blood Establishments

    OpenAIRE

    Bolbate, N

    2008-01-01

    Quality terms and the roots of the matter are analyzed according to European Committee’s recommendations. Essence of process and product quality control as well as essence of quality assurance is described. Quality system’s structure including quality control, quality assurance and management is justified in the article.

  10. Quality control in haemostasis.

    Science.gov (United States)

    Capel, P; Chatelain, B; Leclerq, R; Lust, A; Masure, R; Arnout, J

    1992-01-01

    Laboratory investigation of the haemostatic system deserves particular procedures in the quality control of analytical variables as well as preanalytical variables. This paper reviews the precautions that have to be taken in the blood prelevement, the transport of the tubes and the performance of the laboratory tests aimed to investigate the haemostatic system in order to obtain reliable results.

  11. Ocean Data Quality Control

    Science.gov (United States)

    2011-11-18

    the aero- sol at the coincident time and location of the satellite SST retrievals. This informa- tion is available in the daytime for the anti-solar...are of the same form, such as probabilities or standard normal deviates. A quality control decision-making algorithm in use at the U.S. Navy oceano

  12. VGI QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    C. C. Fonte

    2015-08-01

    Full Text Available This paper presents a framework for considering quality control of volunteered geographic information (VGI. Different issues need to be considered during the conception, acquisition and post-acquisition phases of VGI creation. This includes items such as collecting metadata on the volunteer, providing suitable training, giving corrective feedback during the mapping process and use of control data, among others. Two examples of VGI data collection are then considered with respect to this quality control framework, i.e. VGI data collection by National Mapping Agencies and by the most recent Geo-Wiki tool, a game called Cropland Capture. Although good practices are beginning to emerge, there is still the need for the development and sharing of best practice, especially if VGI is to be integrated with authoritative map products or used for calibration and/or validation of land cover in the future.

  13. Quality control of mammography

    International Nuclear Information System (INIS)

    Hering, K.G.

    1986-01-01

    Random checks of mammograms allow to clearly assess quality controls concerning correct application and operation of the radiographic system indicated by rich contrast in breast tissue images, complete imaging of the mammary parenchyma, freedom from blurs due to motion, efficient breast compression, correct film labelling and perfect maintenance of the film screen system. In addition to these subjective assessments, the following points should be considered when using objective measurement procedures and phantoms: Testing the correct function of X-ray and radiographic equipment by means of test specimens to measure KV standard (KV=Association of German Panel Doctors), mAS and automatic exposure timer; comparing dose and density to initial values and checking film processing by using a sensitometer. Quality assurance handling varies from one KV to the next. That is why the users need to obtain the guidelines of the respective KV relative to radiological quality assurance and to proceed according to these. (orig.) [de

  14. Quality control of intelligence research

    International Nuclear Information System (INIS)

    Lu Yan; Xin Pingping; Wu Jian

    2014-01-01

    Quality control of intelligence research is the core issue of intelligence management, is a problem in study of information science This paper focuses on the performance of intelligence to explain the significance of intelligence research quality control. In summing up the results of the study on the basis of the analysis, discusses quality control methods in intelligence research, introduces the experience of foreign intelligence research quality control, proposes some recommendations to improve quality control in intelligence research. (authors)

  15. Organizing quality control programmes

    International Nuclear Information System (INIS)

    Hjardemaal, O.

    1989-01-01

    When procuring new equipment, performance and safety should be specified, if possible by reference to international standards. Some of the characteristics of the International Electrotechnical Commission (IEC) standard for X-ray generators, in particular the accuracy of the operating data, are described. The quality control tests to be performed after installation comprise acceptance test, status test and constancy test. The first two involve absolute measurements and will be the responsibility of physicists or engineers. Apparently limiting values stipulated by users are a factor of two lower than the limits of the IEC standard. By means of an example it is shown that modern X-ray generators can meet the lower limits of the users without problems. In order to obtain optimum initial quality when procuring new equipment operating data, limiting values must be specified and must be verified by acceptance testing, etc. However, in many countries physicists and engineers are not available for this job. A relatively uncomplicated test object can be used by radiographers for checks on fluoroscopic systems. The findings from such tests in Denmark are compared with other published findings and good agreement is found. Therefore it is proposed that such uncomplicated tests could form the basis for quality evaluation. (author)

  16. Quality control of radiodiagnostics

    International Nuclear Information System (INIS)

    Alonso Diaz, M.; Castaneda Arronte, M.J.; Matorras Galan, P.; Diaz-Caneja Rodriguez, N.; Gutierrez Diaz Velarde, I.

    1993-01-01

    Since May 1990, a program of quality control of diagnostic X-ray equipment is underway in the University Hospital Marques de Valdecilla. This includes the design and application of measuring specifications and procedures corresponding to the different parameters of the equipment. The specified values are presented, as are those obtained for geometric and exposition parameters using the equipment. The specifications for the geometric parameters are fulfilled in an large proportion (between 52 and 86%) of the units, and the rest can easily be adjusted. However, 85% of the units can be made to operate with a field larger than that of the screen of the image monitor and approximately half of them can operate at a shorter focus-to-patient distance than that specified. With respect to the exposition parameters, in general, these units do not fulfill the specifications and their behavior is not uniform. The results obtained indicate that the equipment studied could be made to comply with the proposed specifications if a Maintenance Program were initiated in coordination with that of Quality Control. (Author)

  17. Production And Quality Control Of Radiopharmaceutical 18F-FDG

    International Nuclear Information System (INIS)

    Dinh Thi Bich Lieu; Nguyen Van Si; Vu Van Tien

    2011-01-01

    18 F-FDG is a radiopharmaceutical for imaging diagnosis with PET/CT in Nuclear Medicine. Criteria of injection pharmaceuticals are the highest standards. So, quality assurance and quality control must be followed very strictly. The selection of the procedure for 18 F-FDG has based on several criteria: high chemical efficiency, short synthesis time, toxic component free and etc. The quality control of 18 F-FDG consist many fields such as: nuclear physic (nuclear purity), radiochemistry (radionuclear purity, radiochemical purity), chemistry (chemical purity), radiation measurement (half life), microbiology (pyrogen, endotoxin), etc. which is following USP, BP or EP. (author)

  18. Interaction between production control and quality control

    NARCIS (Netherlands)

    Bij, van der J.D.; Ekert, van J.H.W.

    1999-01-01

    Describes a qualitative study on interaction between systems for production control and quality control within industrial organisations. Production control and quality control interact in a sense. Good performance for one aspect often influences or frustrates the performance of the other. As far as

  19. Quality control in nuclear medicine

    International Nuclear Information System (INIS)

    Leme, P.R.

    1983-01-01

    The following topics are discussed: objectives of the quality control in nuclear medicine; the necessity of the quality control in nuclear medicine; guidelines and recommendations. An appendix is given concerning the guidelines for the quality control and instrumentation in nuclear medicine. (M.A.) [pt

  20. Printing quality control automation

    Science.gov (United States)

    Trapeznikova, O. V.

    2018-04-01

    One of the most important problems in the concept of standardizing the process of offset printing is the control the quality rating of printing and its automation. To solve the problem, a software has been developed taking into account the specifics of printing system components and the behavior in printing process. In order to characterize the distribution of ink layer on the printed substrate the so-called deviation of the ink layer thickness on the sheet from nominal surface is suggested. The geometric data construction the surface projections of the color gamut bodies allows to visualize the color reproduction gamut of printing systems in brightness ranges and specific color sectors, that provides a qualitative comparison of the system by the reproduction of individual colors in a varying ranges of brightness.

  1. Quality control in urinalysis.

    Science.gov (United States)

    Takubo, T; Tatsumi, N

    1999-01-01

    Quality control (QC) has been introduced in laboratories, and QC surveys in urinalysis have been performed by College of American Pathologist, by Japanese Association of Medical Technologists, by Osaka Medical Association and by manufacturers. QC survey in urinalysis for synthetic urine by the reagent strip and instrument made in same manufacturer, and by an automated urine cell analyser provided satisfactory results among laboratories. QC survey in urinalysis for synthetic urine by the reagent strips and instruments made by various manufacturers indicated differences in the determination values among manufacturers, and between manual and automated methods because the reagent strips and instruments have different characteristics, respectively. QC photo survey in urinalysis on the microscopic photos of urine sediment constituents indicated differences in the identification of cells among laboratories. From the results, it is necessary to standardize a reagent strip method, manual and automated methods, and synthetic urine.

  2. A simple and sensitive quality control method of the anaerobic atmosphere for identification and antimicrobial susceptibility testing of anaerobic bacteria

    DEFF Research Database (Denmark)

    Justesen, Tage; Justesen, Ulrik Stenz

    2013-01-01

    The maintenance of a strict anaerobic atmosphere is essential for the culture of strict anaerobic bacteria. We describe a simple and sensitive quality control method of the anaerobic atmosphere, based on the measurement of the zone diameter around a 5-μg metronidazole disk when testing...... an aerotolerant Clostridium perfringens strain. A zone diameter above 27 mm was indicative of acceptable anaerobic conditions....

  3. Species Protection in the European Union : How Strict is Strict?

    NARCIS (Netherlands)

    Schoukens, Hendrik; Bastmeijer, Kees; Born et al., Charles-Hubert

    2015-01-01

    European Union law to protect wild species of plants and animals is generally considered as ‘strict’. Opponents of nature conservation law often pick the species protection components of the EU Bird Directive and Habitat Directive as a prime example of an unnecessary strict regulatory scheme that

  4. Efficient Strictness Analysis of Haskell

    DEFF Research Database (Denmark)

    Jensen, Kristian Damm; Hjæresen, Peter; Rosendahl, Mads

    1994-01-01

    Strictness analysis has been a living field of investigation since Mycroft's original work in 1980, and is getting increasingly significant with the still wider use of lazy functional programming languages. This paper focuses on an actual implementation of a strictness analyser for Haskell....... The analyser uses abstract interpretation with chaotic fixpoint iteration. The demand-driven nature of this iteration technique allows us to use large domains including function domains in the style of Burn et al. 1986 and Wadler 87 and retain reasonable efficiency. The implementation, furthermore, allows us...

  5. Flexible or Strict Taxonomic Organization?

    DEFF Research Database (Denmark)

    Glückstad, Fumiko Kano; Mørup, Morten

    2012-01-01

    This work compares methods for constructing feature-based ontologies that are supposed to be used for culturally-specific knowledge transfer. The methods to be compared are the Terminological Ontology (TO) [1], a method of constructing ontology based on strict principles and rules, and the Infinite...

  6. Dynamic Enforcement of the Strict Integrity Policy

    Institute of Scientific and Technical Information of China (English)

    ZHANGXiangfeng; LIANGHongliang; SUNYufang

    2005-01-01

    The Strict integrity policy (SIP) in Biba's integrity model is widely used in protecting information integrity, but the static integrity labels of both subjects and objects increase compatibility cost of applications and might prevent some operations that are indeed harmless.In order to improve compatibility, Dynamic enforcement of the Strict integrity policy (DESIP) is put forward. The current integrity label attribute of a subject in SIP is replaced with two attributes in DESIP, which are used to confine dynamically the range of objects a subject could be allowed to access. The new rules of access control in DESIP are given for each kind of access mode (observe,modify and invoke) together with the proofs of their valid-ity. Comparison between SIP and DESIP shows that after a sequence of operations, a subject controlled by DESIP tends to behave in a similar way as it is controlled by SIP and DESIP is more compatible than SIP.

  7. Commercial jet fuel quality control

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, K.H.

    1995-05-01

    The paper discusses the purpose of jet fuel quality control between the refinery and the aircraft. It describes fixed equipment, including various types of filters, and the usefulness and limitations of this equipment. Test equipment is reviewed as are various surveillance procedures. These include the Air Transport Association specification ATA 103, the FAA Advisory Circular 150/5230-4, the International Air Transport Association Guidance Material for Fuel Quality Control and Fuelling Service and the Guidelines for Quality Control at Jointly Operated Fuel Systems. Some past and current quality control problems are briefly mentioned.

  8. Strictness Analysis for Attribute Grammars

    DEFF Research Database (Denmark)

    Rosendahl, Mads

    1992-01-01

    interpretation of attribute grammars. The framework is used to construct a strictness analysis for attribute grammars. Results of the analysis enable us to transform an attribute grammar such that attributes are evaluated during parsing, if possible. The analysis is proved correct by relating it to a fixpoint...... semantics for attribute grammars. An implementation of the analysis is discussed and some extensions to the analysis are mentioned....

  9. The trend to get strict

    International Nuclear Information System (INIS)

    Clarke, Chris.

    1997-01-01

    Most policy makers in the USA and Europe are committed to strict environmental liability. The polluter pays principle is seen as popular with voters and easy to defend. For the energy sector, encompassing everything from disused gas works and coal mines to refineries, tank farms and filling stations, the cost of cleaning up old sites can be huge. Within the policy commitment to strict liability there are some issues up for negotiation, however. These include such things as: available defences; the burden of proof; mechanisms for sharing liability at multi-party sites; funding of orphan shares; the protection afforded to lenders. Most governments have shown some flexibility on these issues and some examples from the USA are given. Nevertheless, in Europe the momentum towards comprehensive strict liability regimes seems unrelenting. In the Member states of the European Union, liability laws are either already in place or new laws are in preparation. The European Commission is working on proposals for an EU-wide environmental liability regime but there are formidable obstacles to overcome if it is to become EU law. In the meanwhile, the process of trying to reach agreement at an EU level is likely to strengthen the legislative drive at national level. (UK)

  10. INFORMATION SYSTEM QUALITY CONTROL KNOWLEDGE

    Directory of Open Access Journals (Sweden)

    Vladimir Nikolaevich Babeshko

    2017-02-01

    Full Text Available The development of the educational system is associated with the need to control the quality of educational services. Quality control knowledge is an important part of the scientific process. The penetration of computers into all areas of activities changing approaches and technologies that previously they were used.

  11. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    2004-01-01

    This volume treats the four main categories of Statistical Quality Control: General SQC Methodology, On-line Control including Sampling Inspection and Statistical Process Control, Off-line Control with Data Analysis and Experimental Design, and, fields related to Reliability. Experts with international reputation present their newest contributions.

  12. Quality assurance programme and quality control

    International Nuclear Information System (INIS)

    Alvarez de Buergo, L.

    1979-01-01

    The paper analyses the requirements for the quality assurance and control in nuclear power plant projects which are needed to achieve safe, reliable and economic plants. The author describes the structure for the establishment of a nuclear programme at the national level and the participation of the different bodies involved in a nuclear power plant project. The paper ends with the study of a specific case in Spain. (NEA) [fr

  13. Quality control of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Wallen, O.; Komarov, E.

    1973-01-01

    The International Pharmacopoeia published by WHO constitutes a collection of recommended specifications for pharmaceutical preparations which are not intended to have legal status in any country, but serve as references so that national specifications can be established on a similar basis in any country. Like any pharmacopoeia, it contains monographs for the quality con trol of drugs by means of chemical, physical and simple biological methods, as well as appendices describing general methods. The work on the International Pharmacopoeia is carried out by WHO with the aid of the Expert Advisory Panel on the International Pharmacopoeia and Pharmaceutical Preparations and other specialists from various countries and the Expert Committee on Specifications for Pharmaceutical Preparations. (author)

  14. Quality control of labelled compounds

    International Nuclear Information System (INIS)

    Matucha, M.

    1979-01-01

    Some advantages and disadvantages of methods used for quality control of organic labelled compounds (1 31 I, 14 C) are shortly discussed. The methods used are electrophoresis, ultraviolet and infrared spectrometry, radiogas and thin-layer chromatography. (author)

  15. [Quality control in herbal supplements].

    Science.gov (United States)

    Oelker, Luisa

    2005-01-01

    Quality and safety of food and herbal supplements are the result of a whole of different elements as good manufacturing practice and process control. The process control must be active and able to individuate and correct all possible hazards. The main and most utilized instrument is the hazard analysis critical control point (HACCP) system the correct application of which can guarantee the safety of the product. Herbal supplements need, in addition to standard quality control, a set of checks to assure the harmlessness and safety of the plants used.

  16. Fuel cycle and quality control

    International Nuclear Information System (INIS)

    Stoll, W.

    1979-01-01

    The volume of the fuel cycle is described in its economic importance and its through put, as it is envisaged for the Federal Republic of Germany. Definitions are given for quality continuing usefulness of an object and translated into quality criteria. Requirements on performance of fuel elements are defined. The way in which experimental results are translated into mass production of fuel rods, is described. The economic potential for further quality effort is derived. Future ways of development for quality control organisation and structure are outlined. (Auth.)

  17. Quality control of CANDU6 fuel element in fabrication process

    International Nuclear Information System (INIS)

    Li Yinxie; Zhang Jie

    2012-01-01

    To enhance the fine control over all aspects of the production process, improve product quality, fuel element fabrication process for CANDU6 quality process control activities carried out by professional technical and management technology combined mode, the quality of the fuel elements formed around CANDU6 weak links - - end plug , and brazing processes and procedures associated with this aspect of strict control, in improving staff quality consciousness, strengthening equipment maintenance, improved tooling, fixtures, optimization process test, strengthen supervision, fine inspection operations, timely delivery carry out aspects of the quality of information and concerns the production environment, etc., to find the problem from the improvement of product quality and factors affecting the source, and resolved to form the active control, comprehensive and systematic analysis of the problem of the quality management concepts, effectively reducing the end plug weld microstructure after the failure times and number of defects zirconium alloys brazed, improved product quality, and created economic benefits expressly provided, while staff quality consciousness and attention to detail, collaboration department, communication has been greatly improved and achieved very good management effectiveness. (authors)

  18. SAQC: SNP Array Quality Control

    Directory of Open Access Journals (Sweden)

    Li Ling-Hui

    2011-04-01

    Full Text Available Abstract Background Genome-wide single-nucleotide polymorphism (SNP arrays containing hundreds of thousands of SNPs from the human genome have proven useful for studying important human genome questions. Data quality of SNP arrays plays a key role in the accuracy and precision of downstream data analyses. However, good indices for assessing data quality of SNP arrays have not yet been developed. Results We developed new quality indices to measure the quality of SNP arrays and/or DNA samples and investigated their statistical properties. The indices quantify a departure of estimated individual-level allele frequencies (AFs from expected frequencies via standardized distances. The proposed quality indices followed lognormal distributions in several large genomic studies that we empirically evaluated. AF reference data and quality index reference data for different SNP array platforms were established based on samples from various reference populations. Furthermore, a confidence interval method based on the underlying empirical distributions of quality indices was developed to identify poor-quality SNP arrays and/or DNA samples. Analyses of authentic biological data and simulated data show that this new method is sensitive and specific for the detection of poor-quality SNP arrays and/or DNA samples. Conclusions This study introduces new quality indices, establishes references for AFs and quality indices, and develops a detection method for poor-quality SNP arrays and/or DNA samples. We have developed a new computer program that utilizes these methods called SNP Array Quality Control (SAQC. SAQC software is written in R and R-GUI and was developed as a user-friendly tool for the visualization and evaluation of data quality of genome-wide SNP arrays. The program is available online (http://www.stat.sinica.edu.tw/hsinchou/genetics/quality/SAQC.htm.

  19. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    2001-01-01

    The book is a collection of papers presented at the 5th International Workshop on Intelligent Statistical Quality Control in Würzburg, Germany. Contributions deal with methodology and successful industrial applications. They can be grouped in four catagories: Sampling Inspection, Statistical Process Control, Data Analysis and Process Capability Studies and Experimental Design.

  20. Principles and Practices for Quality Assurance and Quality Control

    Science.gov (United States)

    Jones, Berwyn E.

    1999-01-01

    Quality assurance and quality control are vital parts of highway runoff water-quality monitoring projects. To be effective, project quality assurance must address all aspects of the project, including project management responsibilities and resources, data quality objectives, sampling and analysis plans, data-collection protocols, data quality-control plans, data-assessment procedures and requirements, and project outputs. Quality control ensures that the data quality objectives are achieved as planned. The historical development and current state of the art of quality assurance and quality control concepts described in this report can be applied to evaluation of data from prior projects.

  1. Investigation of Color Constancy in 4.5-Month-Old Infants under a Strict Control of Luminance Contrast for Individual Participants

    Science.gov (United States)

    Yang, Jiale; Kanazawa, So; Yamaguchi, Masami K.; Kuriki, Ichiro

    2013-01-01

    The current study examined color constancy in infants using a familiarization paradigm. We first obtained isoluminance in each infant as defined by the minimum motion paradigm and used these data to control the luminance of stimuli in the main experiments. In the familiarization phase of the main experiment, two identical smiling face patterns…

  2. Quality Control - Nike.Inc

    OpenAIRE

    Walter G. Bishop

    2017-01-01

    The purpose of this paper is to present the illustration of quality control approach, which has been adopted by several organizations, in order to manage and improve their production processes. The approach is referred as total quality management (TQM). This study will discuss the implementation of TQ, within the working environment of Nike Inc. One of the major objectives behind the implementation of TQ is to reduce or completely eliminate potential errors and flaws, within the manufacturing...

  3. Quality assurance, quality control and quality audit in diagnostic radiology

    International Nuclear Information System (INIS)

    Vassileva, J.

    2009-01-01

    Full text:The lecture aims to present contemporary view of quality assurance in X-Ray diagnosis and its practical realization in Bulgaria. In the lecture the concepts of quality assurance, quality control and clinical audit will be defined and their scope will be considered. An answer of the following questions will be given: why is it necessary to determine the dose of patient in X-ray studies, what is the reference dose level and how it is used for dosimetric quantity which characterized the patient's exposure in X-ray, mammography and CT scans and how they are measured, who conducted the measurement and how to keep the records, what are the variations of doses in identical tests and what defines them? The findings from a national survey of doses in diagnostic radiology, conducted in 2008-2009 and the developed new national reference levels will be presented. The main findings of the first tests of radiological equipment and the future role of quality control as well as the concept of conducting clinical audit and its role in quality assurance are also presented. Quality assurance of the diagnostic process with minimal exposure of patients is a strategic goal whose realization requires understanding, organization and practical action, both nationally and in every hospital. To achieve this the important role of education and training of physicians, radiological technicians and medical physicists is enhanced

  4. Quality control of imaging devices

    International Nuclear Information System (INIS)

    Soni, P.S.

    1992-01-01

    Quality assurance in nuclear medicine refers collectively to all aspects of a nuclear medicine service. It would include patient scheduling, radiopharmaceutical preparation and dispensing, radiation protection of patients, staff and general public, preventive maintenance and the care of instruments, methodology, data interpretation and records keeping, and many other small things which contribute directly or indirectly to the overall quality of a nuclear medicine service in a hospital. Quality Control, on the other hand, refers to a signal component of the system and is usually applied in relation to a specific instrument and its performance

  5. Quality control for dose calibrators

    International Nuclear Information System (INIS)

    Mendes, L.C.G.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are accomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintillation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (author)

  6. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    1997-01-01

    Like the preceding volumes, and met with a lively response, the present volume is collecting contributions stressed on methodology or successful industrial applications. The papers are classified under four main headings: sampling inspection, process quality control, data analysis and process capability studies and finally experimental design.

  7. Quality assurance and statistical control

    DEFF Research Database (Denmark)

    Heydorn, K.

    1991-01-01

    In scientific research laboratories it is rarely possible to use quality assurance schemes, developed for large-scale analysis. Instead methods have been developed to control the quality of modest numbers of analytical results by relying on statistical control: Analysis of precision serves...... to detect analytical errors by comparing the a priori precision of the analytical results with the actual variability observed among replicates or duplicates. The method relies on the chi-square distribution to detect excess variability and is quite sensitive even for 5-10 results. Interference control...... serves to detect analytical bias by comparing results obtained by two different analytical methods, each relying on a different detection principle and therefore exhibiting different influence from matrix elements; only 5-10 sets of results are required to establish whether a regression line passes...

  8. The quality control and management of the updating of the process measurement and protection system of HFETR

    International Nuclear Information System (INIS)

    Cao Junru; Duan Tianyuan; Zhao Zengqiao; Xing Rujun; Xia Guanghua; Jiang Yiqun

    2001-01-01

    The author emphasizes the presentation of the quality control and management of implement process. Owing to the strict and scientific organizing, the field implement was completed only in 4 months, and comprehensive operation test of reactor was successful at one go. The management target that is safety, high efficiency and high quality, success at one go, was hit

  9. Quality Assurance/Quality Control Jobs

    Science.gov (United States)

    Fanslau, Melody; Young, Janelle

    The production of a quality and safe food product is essential to the success of any food manufacturing facility. Because of this great importance, a career in quality can be extremely rewarding. Without happy customers willing to buy a product, a company would not be able to survive. Quality issues such as foreign objects, spoiled or mislabeled product, failure to meet net weight requirements, or a recall can all turn customers away from buying a product. The food industry is a customer-driven market in which some consumers are brand loyal based on a history of high quality or in which a single bad experience with a product will turn them away for a lifetime. With this said, the main role of a quality department is to help ensure that quality issues such as these are eliminated or kept to a minimum to maintain or increase the number of customers purchasing their product.

  10. Control of quality in mammography

    International Nuclear Information System (INIS)

    2006-10-01

    The present protocol of quality control/quality assurance in mammography is the result of the work of two regional projects realised in Latin America within the frame of ARCAL with the support of the IAEA. The first is ARCAL LV (RLA/6/043) project on quality assurance/quality control in mammography studies which analysed the present situation of the mammography in the member countries of the project which include: Bolivia, Colombia, Costa Rica, Cuba, El Salvador, Guatemala, Nicaragua, Panama, Paraguay, Peru, Dominican Republic and Republic of Venezuela and the second is ARCAL XLIX (RLA/9/035) project, whose members were Brazil, Colombia, Cuba, Chile, Mexico, and Peru, worked the application of Basic Safety Standards for the protection against ionising radiation with the aim to improve radiation protection in X-ray diagnosis medical practices through the implementation of the Basic Safety Standards (BSS) related to x-ray diagnosis in selected hospitals located in each country involved in the project. The work of both projects had been consolidated and harmonized in the present publication

  11. quality control of the radiopharmaceuticals

    International Nuclear Information System (INIS)

    Boukarra, Hajer; Boubakri, Rania

    2006-01-01

    This work is a contribution to the quality control of two radio pharmaceutical. Our study was carried out on the rat. These results enable us to draw the following conclusions: - the control of the purity of the cerebral tracers (Cytectrenes) is carried out by HPLC by using a detector of radioactivity which offers a great sensitivity. - the radiochemical output of marking of Kit MDP determined by thin chromatography of layer is 99%. - The study of the biodistribution in the rat showed an affinity raised for the feet bone. - These results are in conformity with the European pharmacopoeia, which enables us to require a marketing authorization. (author)

  12. Protocol for quality control of scanners used in the simulation of radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Yanes, Yaima; Alfonso, Rodolfo; Silvestre, Ileana

    2009-01-01

    Computed Tomography (CT) has become the tool fundamental imaging of modern radiation therapy, to locate targets and critical organs and dose planning. Tomographs used for these purposes require strict assurance program quality, which differs in many aspects of monitoring required for diagnostic use only with intention. The aim of this work has been the design and validation of a quality control protocol applicable to any TAC used for simulation, radiotherapy planning. (author)

  13. Radiation measurements and quality control

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1977-01-01

    Accurate measurements are essential to research leading to a successful radiation process and to the commissioning of the process and the facility. On the other hand, once the process is in production, the importance to quality control of measuring radiation quantities (i.e., absorbed dose, dose rate, dose distribution) rather than various other parameters of the process (i.e. conveyor speed, dwell time, radiation field characteristics, product dimensions) is not clearly established. When the safety of the product is determined by the magnitude of the administered dose, as in radiation sterilization, waste control, or food preservation, accuracy and precision of the measurement of the effective dose are vital. Since physical dose measurements are usually simpler, more reliable and reproducible than biological testing of the product, there is a trend toward using standardized dosimetry for quality control of some processes. In many industrial products, however, such as vulcanized rubber, textiles, plastics, coatings, films, wire and cable, the effective dose can be controlled satisfactorily by controlling process variables or by product testing itself. In the measurement of radiation dose profiles by dosimetry, it is necessary to have suitable dose meter calibrations, to account for sources of error and imprecision, and to use correct statistical procedures in specifying dwell times or conveyor speeds and source and product parameters to achieve minimum and maximum doses within specifications. (author)

  14. Metrology and quality control handbook

    International Nuclear Information System (INIS)

    Hofmann, D.

    1983-01-01

    This book tries to present the fundamentals of metrology and quality control in brief surveys. Compromises had to be made in order to reduce the material available to a sensible volume for the sake of clarity. This becomes evident by the following two restrictions which had to made: First, in dealing with the theoretical principles of metrology and quality control, mere reference had to be made in many cases to the great variety of special literature without discussing it to explain further details. Second, in dealing with the application of metrology and quality control techniques in practice, only the basic qantities of the International System of Units (SI) could be taken into account as a rule. Some readers will note that many special measuring methods and equipment known to them are not included in this book. I do hope, however, that this short-coming will show to have a positive effect, too. This book will show the reader how to find the basic quantities and units from the derived quantities and units, and the steps that are necessary to solve any kind of measuring task. (orig./RW) [de

  15. Research of quality control during development of NPP DCS 1E classified software

    International Nuclear Information System (INIS)

    Shi Weihua; Lu Zhenguo; Xie Qi

    2012-01-01

    The Nuclear safety depends on right behavior of 1E software, which is a important part of 1E DCS system. Nowadays, user focus on good function of 1E system, but pay little attention to quality control of 1E software. In fact, it's declared in IEC61513 and IEC60880 that 1E software should under strict quality control during all stages of development. This article is related to the practice of 1E DCS system quality control and explores the QC surveillance for 1E software from the user's point of view. (authors)

  16. Finite Metric Spaces of Strictly Negative Type

    DEFF Research Database (Denmark)

    Hjorth, Poul; Lisonek, P.; Markvorsen, Steen

    1998-01-01

    of Euclidean spaces. We prove that, if the distance matrix is both hypermetric and regular, then it is of strictly negative type. We show that the strictly negative type finite subspaces of spheres are precisely those which do not contain two pairs of antipodal points. In connection with an open problem raised...

  17. Extremely strict ideals in Banach spaces

    Indian Academy of Sciences (India)

    Abstract. Motivated by the notion of an ideal introduced by Godefroy et al. (Stu- dia Math. 104 (1993) 13–59), in this article, we introduce and study the notion of an extremely strict ideal. For a Poulsen simplex K, we show that the space of affine contin- uous functions on K is an extremely strict ideal in the space of continuous ...

  18. Quality control in nuclear medicine

    International Nuclear Information System (INIS)

    Kostadinova, I.

    2007-01-01

    Nuclear medicine comprises diagnosis and therapy of the diseases with radiopharmaceuticals. The ambition of all specialists in our country is their activity to reach European standards. In this connection, a Commission for external audit was formed to evaluate the quality of work in the centers of nuclear medicine. This Commission create a long-lasting programme based on the objective European criteria and the national standard of nuclear medicine, having in mind to increase quality of the work and the expert evaluation of activity in every center. The program comprises measures for quality control of instrumentation, radiopharmaceuticals, performed investigations, obtained results and the whole organization from the receiving of the isotopes to the results of the patients. The ambition is most of the centers to fulfill the requirements. As a conclusion it could be said that not only the quality of everyday nuclear medicine work is enough to increase the prestige of the specialty. It is also necessary we to have understanding expert and financial support from corresponding institutions, incl. Ministry of health for a delivery of a new, contemporary instrumentation with new possibilities. Thus it would be possible Bulgarian patients to reach the high technology apparatuses for an early functional diagnosis of the diseases and optimal treatment, which possibility have the patients from the developed countries. (author)

  19. Quality control programme for radiotherapy

    International Nuclear Information System (INIS)

    Campos de Araujo, A.M.; Viegas, C.C.B.; Viamonte, A.M.

    2002-01-01

    A 3 years pilot programme started in January 2000 with 33 philanthropic cancer institutions that provides medical services to 60% of the patients from the national social security system. Brazil has today 161 radiotherapy services (144 operating with megavoltage equipment). These 33 institutions are distributed over 19 Brazilian states. The aim of this programme is: To create conditions to allow the participants to apply the radiotherapy with quality and efficacy; To promote up dating courses for the physicians, physicists and technicians of these 33 Institutions. With the following objectives: To recommend dosimetric and radiological protection procedures in order to guarantee the tumor prescribed dose and safe working conditions; To help in establishing and implementing these procedures. The main activities are: local quality control evaluations, postal TLD audits in reference conditions, postal TLD audits in off axis conditions and training. The local quality control program has already evaluated 22 institutions with 43 machines (25 Co-60 and 18 linear accelerators). In these visits we perform dosimetric, electrical, mechanical and safety tests. As foreseen, we found more problems among the old Co-60 machines i.e., field flatness, size, symmetry and relative output factors; lasers positioning system alignment; optical distance indicator; radiation and light field coincidence; optical and mechanical distance indicators agreement, than among the linear accelerators i.e., field flatness and size; lasers positioning system alignment; tray interlocking and wedge filter factors

  20. Family Control and Earnings Quality

    Directory of Open Access Journals (Sweden)

    Carolina Bona Sánchez

    2007-06-01

    Full Text Available El trabajo analiza la relación entre el control familiar y la calidad de la información contable en un contexto en el que el tradicional conflicto de agencia entre directivos y accionistas se desplaza a la divergencia de intereses entre accionistas controladores y minoritarios. Los resultados alcanzados muestran que, en comparación con las no familiares, las empresas de naturaleza familiar divulgan unos resultados de mayor calidad, tanto en términos de menores ajustes por devengo discrecionales como de mayor capacidad de los componentes actuales del resultado para predecir los cash flows futuros. Además, el aumento en los derechos de voto en manos de la familia controladora incrementa la calidad de los resultados contables. La evidencia obtenida se muestra consistente con la presencia de un efecto reputación/vinculación a largo plazo asociado a la empresa familiar. Adicionalmente, el trabajo refleja que a medida que disminuye la divergencia entre los derechos de voto y de cash flow en manos de la familia controladora, aumenta la calidad de la información contable.PALABRAS CLAVE: derechos de voto, divergencia, empresa familiar, calidad delresultado, reputación, beneficios privados.This work examines the relationship between family control and earnings quality in a context where the salient agency problem shifts away from the classical divergence between managers and shareholders to conflicts between the controlling owner and minority shareholders. The results reveal that, compared to non-family firms, family firms reveal higher earnings quality in terms of both lower discretionary accruals and greater predictability of future cash flows. They also show a positive relationship between the level of voting rights held by the controlling family and earnings quality. The evidence is consistent with the presence of a reputation/long-term involvement effect associated with the family firm. Moreover, the work reflects that, as the divergence

  1. Physicians, radiologists, and quality control

    International Nuclear Information System (INIS)

    Payne, W.F.

    1973-01-01

    Factors involved in quality control in medical x-ray examinations to achieve the least possible exposure to the patient are discussed. It would be hoped that film quality will remain in the position of paramount importance that it must in order to achieve the greatest amount of diagnostic information on each radiographic examination. At the same time, it is hoped that this can be done by further reducing the exposure of the patient to ionizing radiation by the methods that have been discussed; namely, education of the physician, radiologist, and technologist, modern protective equipment and departmental construction, efficient collimation whether automatic or manual, calibration and output measurement of the radiographic and fluoroscopic units, ongoing programs of education within each department of radiographic facility, film badge monitoring, education of and cooperation with the nonradiologic physician, and hopefully, more intensive programs by the National and State Bureaus and Departments of Radiological Health in education and encouragement to the medical community. (U.S.)

  2. Quality control of pesticide products

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-15

    In light of an established need for more efficient analytical procedures, this publication, which documents the findings of an IAEA coordinated research project (CRP) on “Quality Control of Pesticide Products”, simplifies the existing protocol for pesticide analysis while simultaneously upholding existing standards of quality. This publication includes both a report on the development work done in the CRP and a training manual for use by pesticide analysis laboratories. Based on peer reviewed and internationally recognized methods published by the Association of Analytical Communities (AOAC) and the Collaborative International Pesticides Analytical Council (CIPAC), this report provides laboratories with versatile tools to enhance the analysis of pesticide chemicals and to extend the scope of available analytical repertoires. Adoption of the proposed analytical methodologies promises to reduce laboratories’ use of solvents and the time spent on reconfiguration and set-up of analytical equipment.

  3. Quality control of pesticide products

    International Nuclear Information System (INIS)

    2009-07-01

    In light of an established need for more efficient analytical procedures, this publication, which documents the findings of an IAEA coordinated research project (CRP) on “Quality Control of Pesticide Products”, simplifies the existing protocol for pesticide analysis while simultaneously upholding existing standards of quality. This publication includes both a report on the development work done in the CRP and a training manual for use by pesticide analysis laboratories. Based on peer reviewed and internationally recognized methods published by the Association of Analytical Communities (AOAC) and the Collaborative International Pesticides Analytical Council (CIPAC), this report provides laboratories with versatile tools to enhance the analysis of pesticide chemicals and to extend the scope of available analytical repertoires. Adoption of the proposed analytical methodologies promises to reduce laboratories’ use of solvents and the time spent on reconfiguration and set-up of analytical equipment

  4. Water quality control system and water quality control method

    International Nuclear Information System (INIS)

    Itsumi, Sachio; Ichikawa, Nagayoshi; Uruma, Hiroshi; Yamada, Kazuya; Seki, Shuji

    1998-01-01

    In the water quality control system of the present invention, portions in contact with water comprise a metal material having a controlled content of iron or chromium, and the chromium content on the surface is increased than that of mother material in a state where compression stresses remain on the surface by mechanical polishing to form an uniform corrosion resistant coating film. In addition, equipments and/or pipelines to which a material controlling corrosion potential stably is applied on the surface are used. There are disposed a cleaning device made of a material less forming impurities, and detecting intrusion of impurities and removing them selectively depending on chemical species and/or a cleaning device for recovering drain from various kinds of equipment to feedwater, connecting a feedwater pipeline and a condensate pipeline and removing impurities and corrosion products. Then, water can be kept to neutral purified water, and the concentrations of oxygen and hydrogen in water are controlled within an optimum range to suppress occurrence of corrosion products. (N.H.)

  5. Quality control in breast tomosynthesis

    International Nuclear Information System (INIS)

    Jakubiak, Rosangela Requi; Messias, Pricila Cordeiro; Santos, Marilia Fernanda; Urban, Linei Augusta B.D.

    2014-01-01

    In Brazil breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Breast Digital Tomosynthesis (BDT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared to the mammography. This study presents results of Contrast Ratio Noise tests (CRN) and quality image on a Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CRN was determined with plates Polymethylmethacrylate (PMMA) of 20 to 70 mm thickness and an aluminum plate of 10 mm 2 and 0.2 mm thickness. Image quality was assessed with the ACR Breast Simulator. In assessment of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Were visualized 4.5 fibers and 4 mass in both modes. In 2D mode groups have been identified 3.5 microcalcifications, and 3D were 3 groups. The Mean Glandular Dose for the simulator in 2D mode was 1.17 mGy and 2.35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CRN values, ensuring image quality and dose compatible in 2D and 3D processes

  6. Quality control in breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Jakubiak, R.R.; Messias, P.C.; Santos, M.F., E-mail: requi@utfpr.edu.br [Universidade Tecnologia Federal do Parana (UTFPR), Curitiba, PR (Brazil). Departamento Academico de Fisica; Urban, L.A.B.D., E-mail: lineiurban@hotmail.com [Diagnostico Avancado por Imagem, Curitiba, PR (Brazil)

    2015-07-01

    In Brazil, breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Digital Breasts Tomosynthesis (DBT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared with mammography. This study presents results of Contrast to Noise Ratio (CNR) and image quality evaluation on Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CNR was determined with Polymethylmethacrylate (PMMA) layers of 20 to 70 mm thick and an aluminum foils of 0,2 mm thickness and area of 10 mm². Image quality was assessed with the ACR Breast Simulator. In the evaluation of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Displaying fibers were 4,5 and 4 mass in both modes. In 2D mode were identified 3,5 microcalcifications groups, and 3D showed 3 groups. The Mean Glandular Dose (MGD) for the simulator in 2D mode was 1,17 mGy and 2,35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CNR values, ensuring image quality and compatible dose in 2D and 3D processes. (author)

  7. Quality control in breast tomosynthesis

    International Nuclear Information System (INIS)

    Jakubiak, R.R.; Messias, P.C.; Santos, M.F.

    2015-01-01

    In Brazil, breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Digital Breasts Tomosynthesis (DBT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared with mammography. This study presents results of Contrast to Noise Ratio (CNR) and image quality evaluation on Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CNR was determined with Polymethylmethacrylate (PMMA) layers of 20 to 70 mm thick and an aluminum foils of 0,2 mm thickness and area of 10 mm². Image quality was assessed with the ACR Breast Simulator. In the evaluation of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Displaying fibers were 4,5 and 4 mass in both modes. In 2D mode were identified 3,5 microcalcifications groups, and 3D showed 3 groups. The Mean Glandular Dose (MGD) for the simulator in 2D mode was 1,17 mGy and 2,35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CNR values, ensuring image quality and compatible dose in 2D and 3D processes. (author)

  8. 40 CFR 51.359 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is calibrated and maintained properly, and that inspection, calibration records, and control charts are...

  9. Public healthcare interests require strict competition enforcement.

    Science.gov (United States)

    Loozen, Edith M H

    2015-07-01

    Several countries have introduced competition in their health systems in order to maintain the supply of high quality health care in a cost-effective manner. The introduction of competition triggers competition enforcement. Since healthcare is characterized by specific market failures, many favor healthcare-specific competition enforcement in order not only to account for the competition interest, but also for the healthcare interests. The question is whether healthcare systems based on competition can succeed when competition enforcement deviates from standard practice. This paper analyzes whether healthcare-specific competition enforcement is theoretically sound and practically effective. This is exemplified by the Dutch system that is based on regulated competition and thus crucially depends on getting competition enforcement right. Governments are responsible for correcting market failures. Markets are responsible for maximizing the public healthcare interests. By securing sufficient competitive pressure, competition enforcement makes sure they do. When interpreted according to welfare-economics, competition law takes into account both costs and benefits specific market behavior may have for healthcare. Competition agencies and judiciary are not legitimized to deviate from standard evidentiary requirements. Dutch case law shows that healthcare-specific enforcement favors the healthcare undertakings concerned, but to the detriment of public health care. Healthcare-specific competition enforcement is conceptually flawed and counterproductive. In order for healthcare systems based on competition to succeed, competition enforcement should be strict. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. 2. Product quality control and assurance system

    International Nuclear Information System (INIS)

    1990-01-01

    Product quality control and assurance are dealt with in relation to reliability in nuclear power engineering. The topics treated include product quality control in nuclear power engineering, product quality assurance of nuclear power plant equipment, quality assurance programs, classification of selected nuclear power equipment, and standards relating to quality control and assurance and to nuclear power engineering. Particular attention is paid to Czechoslovak and CMEA standards. (P.A.). 2 figs., 1 tab., 12 refs

  11. Internal quality control: best practice.

    Science.gov (United States)

    Kinns, Helen; Pitkin, Sarah; Housley, David; Freedman, Danielle B

    2013-12-01

    There is a wide variation in laboratory practice with regard to implementation and review of internal quality control (IQC). A poor approach can lead to a spectrum of scenarios from validation of incorrect patient results to over investigation of falsely rejected analytical runs. This article will provide a practical approach for the routine clinical biochemistry laboratory to introduce an efficient quality control system that will optimise error detection and reduce the rate of false rejection. Each stage of the IQC system is considered, from selection of IQC material to selection of IQC rules, and finally the appropriate action to follow when a rejection signal has been obtained. The main objective of IQC is to ensure day-to-day consistency of an analytical process and thus help to determine whether patient results are reliable enough to be released. The required quality and assay performance varies between analytes as does the definition of a clinically significant error. Unfortunately many laboratories currently decide what is clinically significant at the troubleshooting stage. Assay-specific IQC systems will reduce the number of inappropriate sample-run rejections compared with the blanket use of one IQC rule. In practice, only three or four different IQC rules are required for the whole of the routine biochemistry repertoire as assays are assigned into groups based on performance. The tools to categorise performance and assign IQC rules based on that performance are presented. Although significant investment of time and education is required prior to implementation, laboratories have shown that such systems achieve considerable reductions in cost and labour.

  12. Hyperbolic spaces are of strictly negative type

    DEFF Research Database (Denmark)

    Hjorth, Poul G.; Kokkendorff, Simon L.; Markvorsen, Steen

    2002-01-01

    We study finite metric spaces with elements picked from, and distances consistent with, ambient Riemannian manifolds. The concepts of negative type and strictly negative type are reviewed, and the conjecture that hyperbolic spaces are of strictly negative type is settled, in the affirmative....... The technique of the proof is subsequently applied to show that every compact manifold of negative type must have trivial fundamental group, and to obtain a necessary criterion for product manifolds to be of negative type....

  13. Strictly diagonal holomorphic functions on Banach spaces

    Directory of Open Access Journals (Sweden)

    O. I. Fedak

    2016-01-01

    Full Text Available In this paper we investigate the boundedness of holomorphic functionals on a Banach space with a normalized basis $\\{e_n\\}$ which have a very special form $f(x=f(0+\\sum_{n=1}^\\infty c_nx_n^n$ and which we call strictly diagonal. We consider under which conditions strictly diagonal functions are entire and uniformly continuous on every ball of a fixed radius.

  14. 14 CFR 21.139 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Quality control. 21.139 Section 21.139... PROCEDURES FOR PRODUCTS AND PARTS Production Certificates § 21.139 Quality control. The applicant must show that he has established and can maintain a quality control system for any product, for which he...

  15. Quality and reliability control on assemblies

    International Nuclear Information System (INIS)

    Mueller, H.

    1976-01-01

    Taking as an example electronic assemblies in printed circuit board engineering, quality control during manufacture is dealt with. After giving a survey of four phases of quality and reliability control, some specific methods of quality control are dealt with by means of a flowchart, and by some examples the necessity and the success of these measures are shown. (RW) [de

  16. 7 CFR 930.44 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of the...

  17. 33 CFR 385.21 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Quality control. 385.21 Section... Processes § 385.21 Quality control. (a) The Corps of Engineers and the non-Federal sponsor shall prepare a quality control plan, in accordance with applicable Corps of Engineers regulations, for each product that...

  18. 7 CFR 981.42 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in this...

  19. Association between product quality control and process quality control of bulk milk

    NARCIS (Netherlands)

    Velthuis, A.; Asseldonk, van M.A.P.M.

    2010-01-01

    Assessment of dairy-milk quality is based on product quality control (testing bulk-milk samples) and process quality control (auditing dairy farms). It is unknown whether process control improves product quality. To quantify possible association between product control and process control a

  20. Quality control analysis at the hospital

    International Nuclear Information System (INIS)

    Kristensen, K.

    1979-01-01

    Quality control analysis is an integral part of quality assurance. In a system as with radiopharmaceuticals where part of the finishing of the product takes place at individual hospitals, the need for quality control analysis at the hospital can be discussed. Data are presented that stresses the importance of quality control by the manufacturer as a basis for limitation of such work at hospitals. A simplified programme is proposed

  1. Quality control of the SiPM in the application of large HEP experiments

    International Nuclear Information System (INIS)

    Li Yongzheng; Cheng Yue; Wang Kaijun; Li Bocheng; Liang Kun; Yang Ru; Han Dejun

    2012-01-01

    Large-scale high-energy physics (HEP) experiments have strict requirements on the reliability, consistency and service life for the detectors, it is imperative to set up a quality control system for the involved Silicon Photomultipliers (SiPMs). The essential parameters of the SiPMs are numerous, including reversed leakage current, breakdown voltage, dark count rate, gain, photon detection efficiency, pulse high distribution, temperature coefficient and optical crosstalk etc., characterizing of SiPM should follow an optimal measurement procedures and rules to realize the rapid screening and strict quality control. This paper will introduce the new progress of 1 mm × 1 mm large dynamic range SiPM developed in the Novel Device Laboratory, Beijing Normal University, as well as the measurement guidelines and procedures from chips to packaged devices. (authors)

  2. Quality control guarantees the safety of radiotherapy

    International Nuclear Information System (INIS)

    Aaltonen, P.

    1994-01-01

    While radiotherapy equipment has seen some decisive improvements in the last few decades, the technology has also become more complicated. The advanced equipment produces increasingly good treatment results, but the condition of the equipment must be controlled efficiently so as to eliminate any defects that might jeopardise patient safety. The quality assurance measures that are taken to show that certain equipment functions as required are known as quality control. The advanced equipment and stricter requirements set for the precision of radiotherapy have meant that more attention must be paid to quality control. The present radiation legislation stipulates that radiotherapy equipment must undergo regular quality control. The implementation of the quality control is supervised by the Finnish Centre for Radiation and Nuclear Safety (STUK). Hospitals carry out quality control in accordance with a programme approved by STUK, and STUK inspectors periodically visit hospitals to check the results of quality control. (orig.)

  3. Radiopharmaceutical quality control-Pragmatic approach

    International Nuclear Information System (INIS)

    Barbier, Y.

    1994-01-01

    The quality control must be considered in a practical manner. The radiopharmaceuticals are drugs. They must satisfy the quality assurance control. These products are then conform to Pharmacopeia. But sometimes the user must control some data especially radiochemical purity and pH value. On all the administered solutions four controls are compulsory: radionuclide identity, administered radioactivity, organoleptic character and pH

  4. Expert database system for quality control

    Science.gov (United States)

    Wang, Anne J.; Li, Zhi-Cheng

    1993-09-01

    There are more competitors today. Markets are not homogeneous they are fragmented into increasingly focused niches requiring greater flexibility in the product mix shorter manufacturing production runs and above allhigher quality. In this paper the author identified a real-time expert system as a way to improve plantwide quality management. The quality control expert database system (QCEDS) by integrating knowledge of experts in operations quality management and computer systems use all information relevant to quality managementfacts as well as rulesto determine if a product meets quality standards. Keywords: expert system quality control data base

  5. Quality control of activity detectors

    International Nuclear Information System (INIS)

    Surma, M.J.

    2002-01-01

    The conditions decided on radiometric measurements quality as geometry, background, calibration etc. have been described. The testing methods for achieving high quality of radioactivity measurements using nuclear medicine instruments have been recommended

  6. 30 CFR 74.6 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control. 74.6 Section 74.6 Mineral... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and... DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.6 Quality...

  7. Problems of quality assurance and quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Angerstein, W.

    1986-01-01

    Topical problems of quality assurance and quality control in diagnostic radiology are discussed and possible solutions are shown. Complex units are differentiated with reference to physicians, technicians, organization of labour, methods of examination and indication. Quality control of radiologic imaging systems should involve three stages: (1) simple tests carried out by radiologic technicians, (2) measurements by service technicians, (3) testing of products by the manufacturer and independent governmental or health service test agencies. (author)

  8. Quality control in tile production

    Science.gov (United States)

    Kalviainen, Heikki A.; Kukkonen, Saku; Hyvarinen, Timo S.; Parkkinen, Jussi P. S.

    1998-10-01

    This work studies visual quality control in ceramics industry. In tile manufacturing, it is important that in each set of tiles, every single tile looks similar. For example, the tiles should have similar color and texture. Our goal is to design a machine vision system that can estimate the sufficient similarity or same appearance to the human eye. Currently, the estimation is usually done by human vision. Differing from other approaches our aim is to use accurate spectral representation of color, and we are comparing spectral features to the RGB color features. A laboratory system for color measurement is built. Experimentations with five classes of brown tiles are presented. We use chromaticity RGB features and several spectral features for classification with the k-NN classifier and with a neural network, called Self-Organizing Map. We can classify many of the tiles but there are several problems that need further investigations: larger training and test sets are needed, illuminations effects must be studied further, and more suitable spectral features are needed with more sophisticated classifiers. It is also interesting to develop further the neural approach.

  9. Electronuclear Park, Privatization and Civil Strict Liability

    International Nuclear Information System (INIS)

    Mondello, Gerard Camille

    2008-01-01

    The civil strict liability regime of the electronuclear industry is a fundamental variable for preventing risk. Because prices of other energies as oil or gas are becoming higher and unpredictable, nuclear power becomes cost-effective and may favour the partial privatization of nuclear parks. By considering theoretical traditional liability models, we study the conditions that ensure the most efficient safety level when comparing natural monopoly situation and Bertrand duopoly. Our results are that natural monopoly is safer than duopoly only when strict liability is fully applied. We define conditions that neutralize risk for applying some privatization plan to nuclear park

  10. Finite Metric Spaces of Strictly negative Type

    DEFF Research Database (Denmark)

    Hjorth, Poul G.

    If a finite metric space is of strictly negative type then its transfinite diameter is uniquely realized by an infinite extent (“load vector''). Finite metric spaces that have this property include all trees, and all finite subspaces of Euclidean and Hyperbolic spaces. We prove that if the distance...

  11. Shipping/Receiving and Quality Control

    Data.gov (United States)

    Federal Laboratory Consortium — Shipping receiving, quality control, large and precise inspection and CMM machines. Coordinate Measuring Machines, including "scanning" probes, optical comparators,...

  12. Quality control of static irradiation processing products

    International Nuclear Information System (INIS)

    Bao Jianzhong; Chen Xiulan; Cao Hong; Zhai Jianqing

    2002-01-01

    Based on the irradiation processing practice of the nuclear technique application laboratory of Yangzhou Institute of Agricultural Science, the quality control of irradiation processing products is discussed

  13. Establishment for quality control of experimental animal

    International Nuclear Information System (INIS)

    Kim, Tae Hwan; Kim, Soo Kwan; Kim, Tae Kyoung

    1999-06-01

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus

  14. Establishment for quality control of experimental animal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hwan; Kim, Soo Kwan; Kim, Tae Kyoung

    1999-06-01

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus.

  15. Quality Control in Production Processes

    Directory of Open Access Journals (Sweden)

    Prístavka Miroslav

    2016-09-01

    Full Text Available The tools for quality management are used for quality improvement throughout the whole Europe and developed countries. Simple statistics are considered one of the most basic methods. The goal was to apply the simple statistical methods to practice and to solve problems by using them. Selected methods are used for processing the list of internal discrepancies within the organization, and for identification of the root cause of the problem and its appropriate solution. Seven basic quality tools are simple graphical tools, but very effective in solving problems related to quality. They are called essential because they are suitable for people with at least basic knowledge in statistics; therefore, they can be used to solve the vast majority of problems.

  16. Quality control of mammographic systems

    International Nuclear Information System (INIS)

    Espana Lopez, M. L.

    2001-01-01

    High quality in mammography is a difficult objective to achieve, that is the reason for what efforts are made in order to improve equipment, to offer good combinations screen-film, and professional staff dedicated to this technique [es

  17. Quality control education in the community college

    Science.gov (United States)

    Greene, J. Griffen; Wilson, Steve

    1966-01-01

    This paper describes the Quality Control Program at Daytona Beach Junior College, including course descriptions. The program in quality control required communication between the college and the American Society for Quality Control (ASQC). The college has machinery established for certification of the learning process, and the society has the source of teachers who are competent in the technical field and who are the employers of the educational products. The associate degree for quality control does not have a fixed program, which can serve all needs, any more than all engineering degrees have identical programs. The main ideas which would be common to all quality control programs are the concept of economic control of a repetitive process and the concept of developing individual potentialities into individuals who are needed and productive.

  18. Related regulation of quality control of industrial products

    International Nuclear Information System (INIS)

    1983-04-01

    This book introduce related regulation of quality control of industrial products, which includes regulations of industrial products quality control, enforcement ordinance of industrial products quality control, enforcement regulation of quality control of industrial products, designated items with industrial production quality indication, industrial production quality test, and industrial production quality test organization and management tips of factory quality by grade.

  19. Quality control of nuclear medicine instrumentation

    International Nuclear Information System (INIS)

    Mould, R.F.

    1983-09-01

    The proceedings of a conference held by the Hospital Physicists' Association in London 1983 on the quality control of nuclear medicine instrumentation are presented. Section I deals with the performance of the Anger gamma camera including assessment during manufacture, acceptance testing, routine testing and long-term assessment of results. Section II covers interfaces, computers, the quality control problems of emission tomography and the quality of software. Section III deals with radionuclide measurement and impurity assessment and Section IV the presentation of images and the control of image quality. (U.K.)

  20. Quality control in diagnostic immunohistochemistry: integrated on-slide positive controls.

    Science.gov (United States)

    Bragoni, A; Gambella, A; Pigozzi, S; Grigolini, M; Fiocca, R; Mastracci, L; Grillo, F

    2017-11-01

    Standardization in immunohistochemistry is a priority in modern pathology and requires strict quality control. Cost containment has also become fundamental and auditing of all procedures must take into account both these principles. Positive controls must be routinely performed so that their positivity guarantees the appropriateness of the immunohistochemical procedure. The aim of this study is to develop a low cost (utilizing a punch biopsy-PB-tool) procedure to construct positive controls which can be integrated in the patient's tissue slide. Sixteen frequently used control blocks were selected and multiple cylindrical samples were obtained using a 5-mm diameter punch biopsy tool, separately re-embedding them in single blocks. For each diagnostic immunoreaction requiring a positive control, an integrated PB-control section (cut from the appropriate PB-control block) was added to the top right corner of the diagnostic slide before immunostaining. This integrated control technique permitted a saving of 4.75% in total direct lab costs and proved to be technically feasible and reliable. Our proposal is easy to perform and within the reach of all pathology labs, requires easily available tools, its application costs is less than using external paired controls and ensures that a specific control for each slide is always available.

  1. Developing methods of controlling quality costs

    OpenAIRE

    Gorbunova A. V.; Maximova O. N.; Ekova V. A.

    2017-01-01

    The article examines issues of managing quality costs, problems of applying economic methods of quality control, implementation of progressive methods of quality costs management in enterprises with the view of improving the efficiency of their evaluation and analysis. With the aim of increasing the effectiveness of the cost management mechanism, authors introduce controlling as a tool of deviation analysis from the standpoint of the process approach. A list of processes and corresponding eva...

  2. A strictly hyperbolic equilibrium phase transition model

    International Nuclear Information System (INIS)

    Allaire, G; Faccanoni, G; Kokh, S.

    2007-01-01

    This Note is concerned with the strict hyperbolicity of the compressible Euler equations equipped with an equation of state that describes the thermodynamical equilibrium between the liquid phase and the vapor phase of a fluid. The proof is valid for a very wide class of fluids. The argument only relies on smoothness assumptions and on the classical thermodynamical stability assumptions, that requires a definite negative Hessian matrix for each phase entropy as a function of the specific volume and internal energy. (authors)

  3. On Fixed Points of Strictly Causal Functions

    Science.gov (United States)

    2013-04-08

    were defined to be the functions that are strictly contracting with respect to the Cantor metric (also called the Baire distance) on signals over non...in Computer Science, pages 447–484. Springer Berlin / Heidelberg, 1992. [36] George Markowsky. Chain-complete posets and directed sets with...Journal of Logic Programming, 42(2):59–70, 2000. [53] George M. Reed and A. William Roscoe. A timed model for communicating sequential processes. In

  4. Radiation safety and quality control in the cyclotron laboratory

    International Nuclear Information System (INIS)

    Sharma, S.; Krause, G.; Ebadi, M.

    2006-01-01

    Radiation safety was determined to maintain quality control in the cyclotron laboratory. Based on the results of 438 runs in the Faraday cup (20 μA for 10 min), 20 runs on 18 O-water target (40 μA for 2 h) and 10 runs on 18 O-gas targets (30 μA for 45 min), we have established that occupationally exposed workers remain 10 ± 5 times below federal regulatory limits (FRLs) in the cyclotron vault, 30 ± 8 times below FRL in the radiochemistry laboratory and 200 ± 10 times below the FRL outside the cyclotron laboratory during beam operation. (The FRL for unrestricted area are <20 μSv in 1 h.) The non-occupationally exposed workers serving in offices in the vicinity of the cyclotron vault within 100 m distance remained 200 times below the FRL irrespective of beam being on or off, suggesting that routine beam operation of 40 μA for 2 h once a day during office hours is safe provided quality control and system performance measures as discussed in this report are strictly maintained. (authors)

  5. Fuel manufacture and quality control

    International Nuclear Information System (INIS)

    Roepenack, H.; Raab, K.

    1975-01-01

    The different steps in fuel and fuel element manufacturing from the conversion of UF 6 to UO 2 to the assembling of the whole fuel element are shortly described. Each of this fabrication steps must satisfy well-defined quality criteria which are checked in certain analyses or tests. (RB) [de

  6. Quality Control in Mammography: Image Quality and Patient Doses

    International Nuclear Information System (INIS)

    Ciraj Bjelac, O.; Arandjic, D.; Boris Loncar, B.; Kosutic, D.

    2008-01-01

    Mammography is method of choice for early detection of breast cancer. The purpose of this paper is preliminary evaluation the mammography practice in Serbia, in terms of both quality control indicators, i.e. image quality and patient doses. The survey demonstrated considerable variations in technical parameters that affect image quality and patients doses. Mean glandular doses ranged from 0.12 to 2.8 mGy, while reference optical density ranged from 1.2 to 2.8. Correlation between image contrast and mean glandular doses was demonstrated. Systematic implementation of quality control protocol should provide satisfactory performance of mammography units and maintain satisfactory image quality and keep patient doses as low as reasonably practicable. (author)

  7. The temperature control and water quality regulation for steam generator secondary side hydrostatic test

    International Nuclear Information System (INIS)

    Xiao Bo; Liu Dongyong

    2014-01-01

    The secondary side hydrostatic test for the steam generator of M310 unit is to verify the pressure tightness of steam generator secondary side tube sheet and related systems. As for the importance of the steam generator, the water temperature and water quality of hydrostatic test has strict requirements. The discussion on the water temperature control and water quality regulation for the secondary loop hydrostatic test of Fuqing Unit 1 contribute greatly to the guiding work for the preparation of the steam generator pressure test for M310 unit. (authors)

  8. Quality control in the radioactive waste management

    International Nuclear Information System (INIS)

    Rzyski, B.M.

    1989-01-01

    Radioactive waste management as in industrial activities must mantain in all steps a quality control programme. This control extended from materials acquisition, for waste treatment, to the package deposition is one of the most important activities because it aims to observe the waste acceptance criteria in repositories and allows to guarantee the security of the nuclear facilities. In this work basic knowledges about quality control in waste management and some examples of adopted procedures in other countries are given. (author) [pt

  9. Results of pilot project on introducing quality control of mammographic equipment

    International Nuclear Information System (INIS)

    Vasileva, Zh.; Lichev, A.; Dimov, A.; Kostova, E.; Dimov, G.

    2003-01-01

    Objective:The results from a pilot project, realized in the framework of the PHARE Project 'Radiation Protection and Safety in Medical Use of the Ionizing Radiation'. The main goal of the project is the elaboration a quality control program for mammographic equipment and its implementation in 4 radiological units in the country. Another task is to examine the possibility for conducting a mammographic screening using this equipment. Material and methods: The developed quality control program has the following components: test parameters; criteria for intervention; minimal frequency of measurement. Methodologies for measurement of the parameters and assessment of the results in accordance with the European Protocol for physical and technical aspects of the mammographic screening. Standard protocols have been elaborated. Results: The quality program has been tested for three month at different hospitals. Conclusions: Optimization and strict control of the process of film development are needed. The exposure equipment. The quality control program should be implemented on all mammographic equipment in the country. For the performance of mammographic screening a strict selection of the equipment is necessary

  10. Control by quality: proposition of a typology.

    Science.gov (United States)

    Pujo, P; Pillet, M

    The application of Quality tools and methods in industrial management has always had a fundamental impact on the control of production. It influences the behavior of the actors concerned, while introducing the necessary notions and formalizations, especially for production systems with little or no automation, which constitute a large part of the industrial activity. Several quality approaches are applied in the workshop and are implemented at the level of the control. In this paper, the authors present a typology of the various approaches that have successively influenced control, such as statistical process control, quality assurance, and continuous improvement. First the authors present a parallel between production control and quality organizational structure. They note the duality between control, which is aimed at increasing productivity, and quality, which aims to satisfy the needs of the customer. They also note the hierarchical organizational structure of these two systems of management with, at each level, the notion of a feedback loop. This notion is fundamental to any kind of decision making. The paper is organized around the operational, tactical, and strategic levels, by describing for each level the main methods and tools for control by quality. The overview of these tools and methods starts at the operational level, with the Statistical Process Control, the Taguchi technique, and the "six sigma" approach. On the tactical level, we find a quality system approach, with a documented description of the procedures introduced in the firm. The management system can refer here to Quality Assurance, Total Productive Maintenance, or Management by Total Quality. The formalization through procedures of the rules of decision governing the process control enhances the validity of these rules. This leads to the enhancement of their reliability and to their consolidation. All this counterbalances the human, intrinsically fluctuating, behavior of the control

  11. Sensometrics for Food Quality Control

    DEFF Research Database (Denmark)

    Brockhoff, Per B.

    2011-01-01

    The industrial development of innovative and succesful food items and the measuring of food quality in general is difficult without actually letting human beings evaluate the products using their senses at some point in the process. The use of humans as measurement instruments calls for special...... attention in the modelling and data analysis phase. In this paper the focus is on sensometrics – the „metric“ side of the sensory science field. The sensometrics field is introduced and related to the fields of statistics, chemometrics and psychometrics. Some of the most commonly used sensory testing...

  12. Computer controlled quality of analytical measurements

    International Nuclear Information System (INIS)

    Clark, J.P.; Huff, G.A.

    1979-01-01

    A PDP 11/35 computer system is used in evaluating analytical chemistry measurements quality control data at the Barnwell Nuclear Fuel Plant. This computerized measurement quality control system has several features which are not available in manual systems, such as real-time measurement control, computer calculated bias corrections and standard deviation estimates, surveillance applications, evaluaton of measurement system variables, records storage, immediate analyst recertificaton, and the elimination of routine analysis of known bench standards. The effectiveness of the Barnwell computer system has been demonstrated in gathering and assimilating the measurements of over 1100 quality control samples obtained during a recent plant demonstration run. These data were used to determine equaitons for predicting measurement reliability estimates (bias and precision); to evaluate the measurement system; and to provide direction for modification of chemistry methods. The analytical chemistry measurement quality control activities represented 10% of the total analytical chemistry effort

  13. TRAINING SYSTEM OF FUTURE SPECIALISTS: QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    Vladimir A. Romanov

    2015-01-01

    Full Text Available The aim of the investigation is development of innovative strategy of quality control training of engineers and skilled workers (hereinafter – future specialists in educational professional organizations on the principles of social partnership.Methods. Theoretic: theoretic and methodological analysis, polytheoretic synthesis, modeling. Empirical: research and generalization of the system, process and competence – based approaches experience, experiment, observation, surveys, expert evaluation, SWOT-analysis as a method of strategic planning which is to identify the internal and external factors (socio-cultural of the organization surrounding.Results. The strategy of the development of the process of quality control training in educational professional organizations and a predictive model of the system of quality control training for future engineers and workers have been created on the analysis and synthesis of a quantitative specification of the quality, the obtained experience and success in control training of future specialists in educational professional organizations in recent economic and educational conditions.Scientific novelty. There has been built a predicative model of quality control training of future specialists to meet modern standards and the principles of social partnership; the control algorithm of the learning process, developed in accordance with the standards (international of quality ISO in the implementation of the quality control systems of the process approach (matrix-based responsibility, competence and remit of those responsible for the education process in the educational organization, the «problem» terms and diagnostic tools for assessing the quality of professional training of future specialists. The perspective directions of innovation in the control of the quality of future professionals training have been determined; the parameters of a comprehensive analysis of the state of the system to ensure the

  14. 7 CFR 28.441 - Strict Middling Yellow Stained Color.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strict Middling Yellow Stained Color. 28.441 Section... Strict Middling Yellow Stained Color. Strict Middling Yellow Stained Color is color which is deeper than that of Strict Middling Tinged Color. [57 FR 34498, Aug. 5, 1992] ...

  15. 7 CFR 28.412 - Strict Middling Light Spotted Color.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strict Middling Light Spotted Color. 28.412 Section 28... Light Spotted Color. Strict Middling Light Spotted Color is color which in spot or color, or both, is between Strict Middling Color and Strict Middling Spotted Color. ...

  16. CONCRETE STRUCTURES' QUALITY CONTROL IN PRACTICE

    OpenAIRE

    Dolaček-Alduk, Zlata; Blanda, Miroslav

    2011-01-01

    The Croatian civil engineering is characterized by a lack of systematic approach to planning, control and quality assurance in all phases of project realization. The results obtained in establishing the quality management system in some segments of civil engineering production represent initial trends in solving this problem. Benefits are of two types: the achievement of quality for the contractor and obtaining that quaity is being achieved for clients. Execution of concrete structures is a c...

  17. A quality control manual for oral radiology

    International Nuclear Information System (INIS)

    Peixoto, J.E.; Ferreira, R.S.; Bessa, S.O.; Domingues, C.; Gomes, C.A.; Oliveira, S.L.G.; Ortiz, J.A.P.

    1988-01-01

    A quality control manual for oral radiology is showed. The X-ray equipment used for this activity is described, such as the X-ray tube, collimator. The high tension in X-ray tube, the spectra, the quality and the quantity of radiation and the X-ray intensity are also analysed. (C.G.C.) [pt

  18. Quality control of gamma radiation measuring systems

    International Nuclear Information System (INIS)

    Surma, M.J.

    2002-01-01

    The problem of quality control and assurance of gamma radiation measuring systems has been described in detail. The factors deciding of high quality of radiometric measurements as well as statistical testing and calibration of measuring systems have been presented and discussed

  19. Net analyte signal based statistical quality control

    NARCIS (Netherlands)

    Skibsted, E.T.S.; Boelens, H.F.M.; Westerhuis, J.A.; Smilde, A.K.; Broad, N.W.; Rees, D.R.; Witte, D.T.

    2005-01-01

    Net analyte signal statistical quality control (NAS-SQC) is a new methodology to perform multivariate product quality monitoring based on the net analyte signal approach. The main advantage of NAS-SQC is that the systematic variation in the product due to the analyte (or property) of interest is

  20. The regulatory maze of quality control

    International Nuclear Information System (INIS)

    Stone, T.I.

    1987-01-01

    The appropriateness of specific procedures within a quality control program becomes difficult to assess when an attempt is made to collate all of the available information. This task is discussed from the perspective of the Joint Commission (JCAH Accreditation Manual), HHS(quality assurance program recommendations), equipment manufacturers maintenance schedules, and radiology administrative cost concerns

  1. Quality Control Guidelines for SAM Biotoxin Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the pathogen methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  2. Quality Control Guidelines for SAM Radiochemical Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the radiochemistry methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  3. Quality Control Guidelines for SAM Pathogen Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the biotoxin methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  4. Quality Control Guidelines for SAM Chemical Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the chemistry methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  5. Metallographic quality control of welding and brazing

    International Nuclear Information System (INIS)

    Slaughter, G.M.

    1979-01-01

    The value of metallography in assuring integrity in the fabrication of metal and components in energy systems is summarized. Metallography also plays an integral role in quality control of welded and brazed joints

  6. Quality Controlled Local Climatological Data (QCLCD) Publication

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Quality Controlled Local Climatological Data (QCLCD) contains summaries from major airport weather stations that include a daily account of temperature extremes,...

  7. Quality control during construction of power plants

    International Nuclear Information System (INIS)

    Hartstern, R.F.

    1982-01-01

    This paper traces the background and examines the necessity for a program to control quality during the construction phase of a power plant. It also attempts to point out considerations for making these programs cost effective

  8. Developing methods of controlling quality costs

    Directory of Open Access Journals (Sweden)

    Gorbunova A. V.

    2017-01-01

    Full Text Available The article examines issues of managing quality costs, problems of applying economic methods of quality control, implementation of progressive methods of quality costs management in enterprises with the view of improving the efficiency of their evaluation and analysis. With the aim of increasing the effectiveness of the cost management mechanism, authors introduce controlling as a tool of deviation analysis from the standpoint of the process approach. A list of processes and corresponding evaluation criteria in the quality management system of enterprises is introduced. Authors also introduce the method of controlling quality costs and propose it for the practical application, which allows them to determine useful and unnecessary costs at the existing operating plant. Implementing the proposed recommendations in the system of cost management at an enterprise will allow to improve productivity of processes operating and reduce wasted expense on the quality of the process on the basis of determining values of useful and useless costs of quality according to criteria of processes functioning in the system of quality management.

  9. Quality assurance and quality control in mammography: A review

    International Nuclear Information System (INIS)

    BenComo, Jose A.

    2000-01-01

    A mammogram is among the most technically demanding radiographic procedures. The early detection of breast cancer relies on the radiologist's ability to perceive subtle changes in the image that are only perceptible with high-quality imaging. Early detection of breast cancer is only as reliable as the mammogram with which a diagnosis is made, and a mammogram is only as accurate as the system that produces it. A quality assurance (QA) program maximizes the likelihood that the mammographic images will provide adequate diagnostic information for the least possible radiation exposure and cost to the patient. The QA program monitors each phase of operation of the imaging facility beginning with the request for an examination and ending with the interpretation of the referring physician and ensures that the imaging equipment used for the examination will yield the information desired. Because image quality is the most important technical aspect of mammography, this review summarizes the most important QA and quality control issues

  10. Quality control and analysis of radiotracer compounds

    International Nuclear Information System (INIS)

    Sheppard, G.; Thomson, R.

    1977-01-01

    Special emphasis was on the problems and errors possible in quality control and analysis. The principles underlying quality control were outlined, and analytical techniques applicable to radiotracers were described. Chapter concluded with a selection of examples showing the effects of impurities on the use of radiotracers. The subject of quality control and analysis was treated from the viewpoint of the user and those research workers who need to synthesize and analyze their own radiochemicals. The quality characteristics for radiotracers are of two kinds, valuable or attributive. These were discussed in the chapter. For counting low radioactive concentration, scintillation techniques are in general use, whereas ionization techniques are now used mainly for the measurement of high radioactive concentrations or large quantities of radioactivity, for scanning chromatograms, and a number of very specific purposes. Determination of radionuclidic purity was discussed. Use of radiotracers in pharmaceuticals were presented. 4 figures, 6 tables

  11. Network-based production quality control

    Science.gov (United States)

    Kwon, Yongjin; Tseng, Bill; Chiou, Richard

    2007-09-01

    This study investigates the feasibility of remote quality control using a host of advanced automation equipment with Internet accessibility. Recent emphasis on product quality and reduction of waste stems from the dynamic, globalized and customer-driven market, which brings opportunities and threats to companies, depending on the response speed and production strategies. The current trends in industry also include a wide spread of distributed manufacturing systems, where design, production, and management facilities are geographically dispersed. This situation mandates not only the accessibility to remotely located production equipment for monitoring and control, but efficient means of responding to changing environment to counter process variations and diverse customer demands. To compete under such an environment, companies are striving to achieve 100%, sensor-based, automated inspection for zero-defect manufacturing. In this study, the Internet-based quality control scheme is referred to as "E-Quality for Manufacturing" or "EQM" for short. By its definition, EQM refers to a holistic approach to design and to embed efficient quality control functions in the context of network integrated manufacturing systems. Such system let designers located far away from the production facility to monitor, control and adjust the quality inspection processes as production design evolves.

  12. 20. Quality assurance and quality control in nuclear medicine

    International Nuclear Information System (INIS)

    Vavrejn, B.

    1989-01-01

    Quality control principles to be applied when taking over and using nuclear medicine instrumentation are given. Such instrumentation includes activity meters, gamma detectors for in vitro measurements (manual or automated instruments), gamma detectors for in vivo measurements (with one or several probes), 'movable' scintigraphs and 'steady' scintigraphs (gamma cameras). (Z.S.)

  13. Quality control in 99m technetium radiopharmaceuticals

    International Nuclear Information System (INIS)

    Leon Cabana, Alba

    1994-01-01

    This work means about the quality control in Tc radiopharmaceuticals preparation at hospitalary levels. Several steps must be used in a Nuclear Medicine Laboratory, such as proceeding,radiopharmaceuticals kits preparation, and dispensation materials,glasses,stopper,physical aspects,identification,ph control,storage,and reactif kits

  14. K-type geomagnetic index nowcast with data quality control

    Directory of Open Access Journals (Sweden)

    René Warnant

    2011-07-01

    Full Text Available

    A nowcast system for operational estimation of a proxy K-type geomagnetic index is presented. The system is based on a fully automated computer procedure for real-time digital magnetogram data acquisition that includes screening of the dataset and removal of the outliers, estimation of the solar regular variation (SR of the geomagnetic field, calculation of the index, and issuing of an alert if storm-level activity is indicated. This is a time-controlled (rather than event-driven system that delivers the regular output of: the index value, the estimated quality flag, and eventually, an alert. The novel features provided are first, the strict control of the data input and processing, and second, the increased frequency of production of the index (every 1 h. Such quality control and increased time resolution have been found to be of crucial importance for various applications, e.g. ionospheric monitoring, that are of particular interest to us and to users of our service. The nowcast system operability, accuracy and precision have been tested with instantaneous measurements from recent years. A statistical comparison between the nowcast and the definitive index values shows that the average root-mean-square error is smaller than 1 KU. The system is now operational at the site of the Geophysical Centre of the Royal Meteorological Institute in Dourbes (50.1ºN, 4.6ºE, and it is being used for alerting users when geomagnetic storms take place.

  15. PACS quality control and automatic problem notifier

    Science.gov (United States)

    Honeyman-Buck, Janice C.; Jones, Douglas; Frost, Meryll M.; Staab, Edward V.

    1997-05-01

    One side effect of installing a clinical PACS Is that users become dependent upon the technology and in some cases it can be very difficult to revert back to a film based system if components fail. The nature of system failures range from slow deterioration of function as seen in the loss of monitor luminance through sudden catastrophic loss of the entire PACS networks. This paper describes the quality control procedures in place at the University of Florida and the automatic notification system that alerts PACS personnel when a failure has happened or is anticipated. The goal is to recover from a failure with a minimum of downtime and no data loss. Routine quality control is practiced on all aspects of PACS, from acquisition, through network routing, through display, and including archiving. Whenever possible, the system components perform self and between platform checks for active processes, file system status, errors in log files, and system uptime. When an error is detected or a exception occurs, an automatic page is sent to a pager with a diagnostic code. Documentation on each code, trouble shooting procedures, and repairs are kept on an intranet server accessible only to people involved in maintaining the PACS. In addition to the automatic paging system for error conditions, acquisition is assured by an automatic fax report sent on a daily basis to all technologists acquiring PACS images to be used as a cross check that all studies are archived prior to being removed from the acquisition systems. Daily quality control is preformed to assure that studies can be moved from each acquisition and contrast adjustment. The results of selected quality control reports will be presented. The intranet documentation server will be described with the automatic pager system. Monitor quality control reports will be described and the cost of quality control will be quantified. As PACS is accepted as a clinical tool, the same standards of quality control must be established

  16. Exposure parameters in fluoroscopy equipment. Quality control

    International Nuclear Information System (INIS)

    Alonso, M.; Castaneda, M.J.; Matorras, P.; Diaz-Caneja, N.; Gutierrez, I.

    1992-01-01

    Within the quality control program in Diagnostic Radiology currently being undertaken at the 'Marques de Valdecilla' University Hospital, the corresponding specification and procedure prototypes for the control of conventional radioscopy equipment have been elaborated and applied. This paper presents the values proposed in the specifications and those obtained for the following radioscopy equipment parameters: reference kerma, and its reproducibility, kerma linearity, maximum kerma at the skin, and total filtration. The results obtained indicate that the equipment studied could comply with specified requirements if a Maintenance Program were to be implemented in coordination with the Quality Control Program. (author)

  17. Quality Control and Quality Assurance of Radiation Oncology

    International Nuclear Information System (INIS)

    Abaza, A.

    2016-01-01

    Radiotherapy (RT) has played important roles in cancer treatment for more than one century. The development of RT techniques allows high-dose irradiation to tumors while reducing the radiation doses delivered to surrounding normal tissues. However, RT is a complex process and involves understanding of the principles of medical physics, radiobiology, radiation safety, dosimetry, radiation treatment planning, simulation and interaction of radiation with other treatment modalities. Each step in the integrated process of RT needs quality control and quality assurance (QA) to prevent errors and to ensure that patients will receive the prescribed treatment correctly. The aim of this study is to help the radio therapists in identifying a system for QA that balances patient safety and quality with available resources. Recent advances in RT focus on the need for a systematic RT QA program that balances patient safety and quality with available resources. It is necessary to develop more formal error mitigation and process analysis methods, such as failure mode and effect analysis (FMEA), to focus available QA resources optimally on the process components. External audit programs are also effective. Additionally, Clinical trial QA has a significant role in enhancing the quality of care. The International Atomic Energy Agency (IAEA) has operated both an on-site and off-site postal dosimetry audit to improve practice and to assure the dose from RT equipment. Both postal dosimetry audit and clinical trial RTQA, especially for advanced technologies, in collaboration with global networks, will serve to enhance patient safety and quality of care

  18. Strict Liability Versus Policy and Regulation for Environmental Protection and Agricultural Waste Management in Malaysia

    Directory of Open Access Journals (Sweden)

    Mohd Bakri Ishak

    2010-01-01

    Full Text Available Basically, strict liability is part of the mechanism for expressing judgment or sentence by using direct evidence. This principle is very useful in order to obtain remedies from any damage either directly or indirectly. The principle in Rylands v Fletcher is responsible on imposing strict liability where if something brought onto land or collected there escapes liability under this rule can include not only the owner of land but also those who control or occupation on it. However, as a matter of fact, policy and regulation are also important in taking any action against any party who are responsible for environmental pollution or damage, which may include mismanagement of waste or industrial waste or agricultural waste. There are certain policies and regulations on environmental protection such as the National Environmental Policy, certain Acts and several regulations under the Environmental Quality Act 1974 (Act 127, which are very useful for agricultural waste management inter alia: Waters Act 1920 (Act 418, Environmental Quality (Prescribed Premises (Crude Palm Oil Regulations 1977, Environmental Quality (Prescribed Premises (Raw Natural Rubber Regulations 1978, Environmental Quality (Sewage and Industrial Effluents Regulations 1979, and Environmental Quality (Compounding of Offences Rules 1978. As a matter of fact, we should realize that time is of an essence for any parties which are involved in court cases and especially in avoiding the element of externality, which is commonly suffered by the government. In making this paper, therefore, some element of comparison with certain developed jurisdiction such as in the United Kingdom and Japan could not be avoided in order to obtain better outcome and to be more practical for the purpose of environmental protection and agricultural waste management.

  19. Development of the gaharu oil quality control

    International Nuclear Information System (INIS)

    Chong Saw Peng; Mohd Fajri Osman; Shyful Azizi Abdul Rahman; Khairuddin Abdul Rahim; Mat Rasol Awang

    2010-01-01

    Gaharu (Agar wood) is a secondary metabolite produces by the Aquilaria spp. and accumulates in the plant cell in oleoresin form. The essential oil known as gaharu oil can be extracted from this oleoresin gaharu via varies extraction method such as the water distillation, solvent extraction, pressurize extraction and etc. The gaharu oil extracted through different methods will give different fragrances. Besides, different source of materials will also give different in chemical profiles. In gaharu oil trading market, most of the buyers request quality assurance from the gaharu oil manufacturer to assure the gaharu oil purchased meets their standard requirement. Since there is a demand on gaharu oil quality assurance then it become a need to develop the gaharu oil quality control method in order to have a standard quality control of gaharu oil presented in a certificate of analysis and verified by laboratory. (author)

  20. Quality control in diagnostic radiology - patient dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Prlic, I; Radalj, Z; Brumen, V; Cerovac, H [Institute for Medical Research and Occupational Health, Laboratory for Radiation Protection and Dosimetry, Zagreb (Croatia); Gladic, J [Institute for Physics, Laboratory for Solid State Physics, Zagreb (Croatia); Tercek, V [Clinical Hospital Sisters of Mercy, Health Physics Department, Zagreb (Croatia)

    1997-12-31

    In order to establish the Quality Criteria for diagnostic radiographic images in the radiology departments in Republic of Croatia we have started the several Quality Control projects on the field. The measurements are performed according to some methodology recommendations in our law but the methodology, measurement principles, measurement equipment, phantoms, measurable parameters for the good use by radiographers, statistical and numerical evaluation, dosimetric philosophy etc. where first recognized as a private/or group hazard of each person involved in the procedure of evaluation of diagnostic radiology images/diagnosis. The important quality elements of the imaging process are: the diagnostic quality of the radiographic image, the radiation dose to the patient and the choice of the radiographic technique. This depends on the x-ray unit (tube) radiation quality, image processing quality and final image evaluation quality. In this paper we will show how the Quality Control measurements can be easily connected to the dose delivered to the patient for the known diagnostic procedure and how this can be used by radiographers in their daily work. The reproducibility of the x-ray generator was checked before the service calibration and after the service calibration. The table of kV dependence and output dose per mAs was calculated and the ESD (entrance surface dose) was measured/calculated for the specific diagnostic procedure. After the phantom calculation were made and the dose prediction for the given procedure was done, measurements were done on the patients (digital dosemeters, TLD and film dosemeter combinations). We are claiming that there is no need to measure each patient if the proper Quality Control measurements are done and the proper table of ESD for each particular x-ray tube in diagnostic departments is calculated for the radiographers daily use. (author). 1 example, 1 fig., 13 refs.

  1. Quality control in paediatric nuclear medicine

    International Nuclear Information System (INIS)

    Fischer, S.; Hahn, K.

    1997-01-01

    Nuclear medicine examinations in children require a maximum in quality. This is true for the preparation of the child and parents, the imaging procedure, processing and documentation. It is necessary that quality control through all steps is performed regularly. The aim must be that the children receive a minimum radiation dose, while there needs to be a high quality in imaging and clinical information from the study. Furthermore the child should not be too much psychologically affected by the nuclear medicine examination. (orig.) [de

  2. Quality Assurance and Quality Control in TLD Measurement

    International Nuclear Information System (INIS)

    Bhuiyan, S.I.; Qronfla, M.M.; Abulfaraj, W.H.; Kinsara, A.A.; Taha, T.M.; Molla, N.I.; Elmohr, S.M.

    2008-01-01

    TLD technique characterized by high precision and reproducibility of dose measurement is presented by addressing pre-readout annealing, group sorting, dose evaluation, blind tests, internal dose quality audit and external quality control audits. Two hundred and forty TLD chips were annealed for 1 hour at 4000 degree C followed by 2 h at 1000 degree C. After exposure of 1 mGy from 90 Sr irradiator TLDs were subjected to pre-readout annealing at 1000 degree C, then readout, sorted into groups each with nearly equal sensitivity. Upon repeating the procedures, TLDs having response >3.5% from group mean were dropped to assuring group stability. Effect of pre-readout annealing has been studied. Series of repeated measurements were conducted to stabilize calibration procedures and DCF generation using SSDL level 137 Cs calibrator, dose master, ionization chambers. Performed internal dose quality audits, blind tests and validated by external QC tests with King Abdulaziz City of Science and Technology

  3. Frontiers in statistical quality control 11

    CERN Document Server

    Schmid, Wolfgang

    2015-01-01

    The main focus of this edited volume is on three major areas of statistical quality control: statistical process control (SPC), acceptance sampling and design of experiments. The majority of the papers deal with statistical process control, while acceptance sampling and design of experiments are also treated to a lesser extent. The book is organized into four thematic parts, with Part I addressing statistical process control. Part II is devoted to acceptance sampling. Part III covers the design of experiments, while Part IV discusses related fields. The twenty-three papers in this volume stem from The 11th International Workshop on Intelligent Statistical Quality Control, which was held in Sydney, Australia from August 20 to August 23, 2013. The event was hosted by Professor Ross Sparks, CSIRO Mathematics, Informatics and Statistics, North Ryde, Australia and was jointly organized by Professors S. Knoth, W. Schmid and Ross Sparks. The papers presented here were carefully selected and reviewed by the scientifi...

  4. Quality control procedures in positron tomography

    International Nuclear Information System (INIS)

    Spinks, T.; Jones, T.; Heather, J.; Gilardi, M.

    1989-01-01

    The derivation of physiological parameters in positron tomography relies on accurate calibration of the tomograph. Normally, the calibration relates image pixel count density to the count rate from an external blood counter per unit activity concentration in each device. The quality control of the latter is simple and relies on detector stability assessed by measurement of a standard source of similar geometry to a blood sample. The quality control of the tomographic data depends on (i) detector stability, (ii) uniformity of calibration and normalisation sources and (iii) reproducibility of the attenuation correction procedure. A quality control procedure has been developed for an 8 detector ring (15 transaxial plane) tomograph in which detector response is assessed by acquiring data from retractable transmission ring sources. These are scanned daily and a print out of detector efficiencies is produced as well as changes from a given data. This provides the raw data from which decisions on recalibration or renormalisation are made. (orig.)

  5. Quality control of the activity meter

    International Nuclear Information System (INIS)

    Rodrigues, Marlon da Silva Brandão; Sá, Lídia Vasconcelos de

    2017-01-01

    Objective: To carry out a comparative analysis of national and international standards regarding the quality control of the activity meter used in Nuclear Medicine Services in Brazil. Material and methods: Quality control protocols from the International Atomic Energy Agency (IAEA), American Association of Physicists in Medicine (AAPM) and International Electrotechnical Commission (IEC) were pointed out and compared with requirements from both regulatory Brazilian agencies, National Surveillance Agency (ANVISA) and National Nuclear Energy Commission (CNEN). Results: The daily routine tests recommended by the regulatory agencies do not have significant differences; in contrast the tests with higher periodicities like (accuracy, linearity and precision) have differences discrepant. Conclusion: In view of the comparative analysis carried out, it is suggested that the national recommendations for the quality control tests of the activity meter should be checked and evaluated, with emphasis on the semiannual and annual periodicity tests. (author)

  6. Quality control of 11C-carfentanil

    International Nuclear Information System (INIS)

    Zhang Xiaojun; Zhang Jinming; Tian Jiahe; Xiang Xiaohui

    2013-01-01

    To study the quality control of 11 C-Carfentanil injection, physical, chemical and biological identification were used. The chemical and radiochemical purity of 11 C-Carfentanil Injection were detected by HPLC and Flower Count system; measured the quantity of product by LC-MS, specific activity was calculated later; The PTS was used to detect endotoxin, and other quality control methods were put up to guarantee the security of its clinical application. The produce appeared colorless and transparent, the radiochemical purity was more than 98%, content of the endotoxin was less than 5 EU/mL. The result showed that 11 C-Carfentanil injection had fulfilled pharmaceutical quality control request and could be applied safely to animal experiment and clinical diagnosis. (authors)

  7. Protein quality control in the nucleus

    DEFF Research Database (Denmark)

    Nielsen, Sofie V.; Poulsen, Esben Guldahl; Rebula, Caio A.

    2014-01-01

    to aggregate, cells have evolved several elaborate quality control systems to deal with these potentially toxic proteins. First, various molecular chaperones will seize the misfolded protein and either attempt to refold the protein or target it for degradation via the ubiquitin-proteasome system...... to be particularly active in protein quality control. Thus, specific ubiquitin-protein ligases located in the nucleus, target not only misfolded nuclear proteins, but also various misfolded cytosolic proteins which are transported to the nucleus prior to their degradation. In comparison, much less is known about...... these mechanisms in mammalian cells. Here we highlight recent advances in our understanding of nuclear protein quality control, in particular regarding substrate recognition and proteasomal degradation....

  8. The Study on quality control of nuclear power installation project

    International Nuclear Information System (INIS)

    Wu Jie

    2008-01-01

    The quality planning, quality assurance and quality control are discussed by applying the quality control (QC) theory and combining the real situation of the Qinshan II project. This paper is practical and plays an active role in instruction of project quality control by applying the above QC theory and control techniques. (authors)

  9. A quality control program for radiation sources

    International Nuclear Information System (INIS)

    Almeida, C.E. de; Sibata, C.H.; Cecatti, E.R.; Kawakami, N.S.; Alexandre, A.C.; Chiavegatti Junior, M.

    1982-01-01

    An extensive quality control program was established covering the following areas: physical parameters of the therapeutical machines, dosimetric standards, preventive maintenance of radiation sources and measuring instruments. A critical evaluation of this program was done after two years (1977-1979) of routine application and the results will be presented. The fluctuation on physical parameters strongly supports the efforts and cost of a quality control program. This program has certainly improved the accuracy required on the delivery of the prescribed dose for radiotherapy treatment. (Author) [pt

  10. Quality control of nuclear medicine instruments 1991

    International Nuclear Information System (INIS)

    1991-05-01

    This document gives detailed guidance on the quality control of various instruments used in nuclear medicine. A first preliminary document was drawn up in 1979. A revised and extended version, incorporating recommended procedures, test schedules and protocols was prepared in 1982. The first edition of ''Quality Control of Nuclear Medicine Instruments'', IAEA-TECDOC-317, was printed in late 1984. Recent advances in the field of nuclear medicine imaging made it necessary to add a chapter on Camera-Computer Systems and another on SPECT Systems. Figs and tabs

  11. Quality control of nuclear medicine instruments, 1991

    International Nuclear Information System (INIS)

    1996-12-01

    This document gives detailed guidance on the quality control of various instruments used in nuclear medicine. A first preliminary document was drawn up in 1979. A revised and extended version, incorporating recommended procedures, test schedules and protocols was prepared in 1982. The first edition of 'Quality Control of Nuclear Medicine Instruments', IAEA-TECDOC-317, was printed in late 1984. Recent advances in the field of nuclear medicine imaging made it necessary to add a chapter on Camera-Computer Systems and another on SPECT Systems

  12. HPLC for quality control of polyimides

    Science.gov (United States)

    Young, P. R.; Sykes, G. F.

    1979-01-01

    High Pressure Liquid Chromatography (HPLC) as a quality control tool for polyimide resins and prepregs are presented. A data base to help establish accept/reject criteria for these materials was developed. This work is intended to supplement, not replace, standard quality control tests normally conducted on incoming resins and prepregs. To help achieve these objectives, the HPLC separation of LARC-160 polyimide precursor resin was characterized. Room temperature resin aging effects were studied. Graphite reinforced composites made from fresh and aged resin were fabricated and tested to determine if changes observed by HPLC were significant.

  13. Statistical quality control a loss minimization approach

    CERN Document Server

    Trietsch, Dan

    1999-01-01

    While many books on quality espouse the Taguchi loss function, they do not examine its impact on statistical quality control (SQC). But using the Taguchi loss function sheds new light on questions relating to SQC and calls for some changes. This book covers SQC in a way that conforms with the need to minimize loss. Subjects often not covered elsewhere include: (i) measurements, (ii) determining how many points to sample to obtain reliable control charts (for which purpose a new graphic tool, diffidence charts, is introduced), (iii) the connection between process capability and tolerances, (iv)

  14. Technical quality control - constancy controls for digital mammography systems

    International Nuclear Information System (INIS)

    Pedersen, K.; Landmark, I.D.; Bredholt, K.; Hauge, I.H.R.

    2009-04-01

    To ensure the quality of mammographic images, so-called constancy control tests are performed frequently. The report contains a programme for constancy control of digital mammography systems, encompassing the mammography unit, computed radiography (CR) systems, viewing conditions and displays, printers, and procedures for data collection for patient dose calculations. (Author)

  15. STRICT STABILITY OF IMPULSIVE SET VALUED DIFFERENTIAL EQUATIONS

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    In this paper, we develop strict stability concepts of ODE to impulsive hybrid set valued differential equations. By Lyapunov’s original method, we get some basic strict stability criteria of impulsive hybrid set valued equations.

  16. Control cards as a statistical quality control resource

    Directory of Open Access Journals (Sweden)

    Aleksandar Živan Drenovac

    2013-02-01

    Full Text Available Normal 0 false false false MicrosoftInternetExplorer4 This paper proves that applying of statistical methods can significantly contribute increasing of products and services quality, as well as increasing of institutions rating. Determining of optimal, apropos anticipatory and limitary values, is based on sample`s statistical analyze. Control cards represent very confident instrument, which is simple for use and efficient for control of process, by which process is maintained in set borders. Thus, control cards can be applied in quality control of procesess of weapons and military equipment production, maintenance of technical systems, as well as for seting of standards and increasing of quality level for many other activities.

  17. A Comparison of Power Quality Controllers

    Directory of Open Access Journals (Sweden)

    Petr Černek

    2012-01-01

    Full Text Available This paper focuses on certain types of FACTS (Flexibile AC Transmission System controllers, which can be used for improving the power quality at the point of connection with the power network. It focuses on types of controllers that are suitable for use in large buildings, rather than in transmission networks. The goal is to compare the features of the controllers in specific tasks, and to clarify which solution is best for a specific purpose. It is in some cases better and cheaper to use a combination of controllers than a single controller. The paper also presents the features of a shunt active harmonic compensator, which is a very modern power quality controller that can be used in many cases, or in combination with other controllers. The comparison was made using a matrix diagram that, resulted from mind mapsand other analysis tools. The paper should help engineers to choose the best solution for improving the power quality in a specific power network at distribution level.

  18. Comparative evaluation of image quality of various digital radiology systems and quality control and optimization of radiation protection at the Amiens university hospital

    International Nuclear Information System (INIS)

    Foro, Saturnin Didace L.

    2004-01-01

    This study was centered on two axes: the first is the comparative evaluation of image quality of various numerical radiology system, the second is the quality control and the optimization of protection against radiation. The publication of directive 97/43 Euratom from council of June 30, 1997 and consequently, the decree of February 12, 2004 founded a strict lawful framework that is engaged to respect the University Hospital of Amiens by the installation of a operational dosimetry system and the application of February 12, 2004 decree. (author) [fr

  19. 7 CFR 28.406 - Strict Good Ordinary Color.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strict Good Ordinary Color. 28.406 Section 28.406... for the Color Grade of American Upland Cotton § 28.406 Strict Good Ordinary Color. Strict Good Ordinary Color is color which is within the range represented by a set of samples in the custody of the...

  20. 7 CFR 28.404 - Strict Low Middling Color.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strict Low Middling Color. 28.404 Section 28.404... for the Color Grade of American Upland Cotton § 28.404 Strict Low Middling Color. Strict Low Middling Color is color which is within the range represented by a set of samples in the custody of the United...

  1. 7 CFR 28.402 - Strict Middling Color.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strict Middling Color. 28.402 Section 28.402... for the Color Grade of American Upland Cotton § 28.402 Strict Middling Color. Strict Middling Color is color which is within the range represented by a set of samples in the custody of the United States...

  2. Data Organization for Quality Control Test

    International Nuclear Information System (INIS)

    Yahaya Talib; Glam Hadzir Patai Mohamad; Wan Hamirul Bahrin Wan Kamal

    2011-01-01

    Test data and results for quality control of Mo-99/ Tc-99m generator shall be organized properly. A computer program was developed using Visual Basic 6.0 to process test data, store data and results to specific folder, generate test reports and certificates. Its performance has been evaluated and tested. (author)

  3. Water quality control program in experimental circuits

    International Nuclear Information System (INIS)

    Cegalla, Miriam A.

    1996-01-01

    The Water Quality Control Program of the Experimental Circuits visualizes studying the water chemistry of the cooling in the primary and secondary circuits, monitoring the corrosion of the systems and studying the mechanism of the corrosion products transport in the systems. (author)

  4. Studies of quality control procedures for radiopharmaceuticals

    International Nuclear Information System (INIS)

    Zivanovic, M.; Trott, N.G.

    1983-01-01

    In this paper, a short description is given of a radiopharmaceutical preparation suite set up at the Royal Marsden Hospital and an account is presented of methods used for quality control of radiopharmaceuticals and of the results obtained over a period of about two and a half years

  5. Materials, methods and quality control, ch. 3

    International Nuclear Information System (INIS)

    Vader, H.L.

    1978-01-01

    A description of the chemical reagents, the 125 I-labelled angiotensin I, the antiserum and the standards is given. A modified measuring method with the New England Nuclear kit for angiotensin I radioimmunoassay is presented as well as the quality control data

  6. Guidelines for radriopharmaceutical quality control in hospitals

    International Nuclear Information System (INIS)

    Welsh, W.J.

    1982-01-01

    This document has been prepared to assist hospital administrators in ensuring that adequate quality control is performed on radiopharmaceuticals administered to their patients. Three sets of guidelines are presented, the degree of sophistication being dependent on the amount of hospital involvement in the radiopharmaceutical preparation

  7. Quality Control Of Selected Pesticides With GC

    Energy Technology Data Exchange (ETDEWEB)

    Karasali, H. [Benaki Phytopathological Institute Laboratory of Physical and Chemical Analysis of Pesticides, Ekalis (Greece)

    2009-07-15

    The practical quality control of selected pesticides with GC is treated. Detailed descriptions are given on materials and methods used, including sample preparation and GC operating conditions. The systematic validation of multi methods is described, comprising performance characteristics in routine analysis, like selectivity, specificity etc. This is illustrated by chromatograms, calibration curves and tables derived from real laboratory data. (author)

  8. Outsourcing University Degrees: Implications for Quality Control

    Science.gov (United States)

    Edwards, Julie; Crosling, Glenda; Edwards, Ron

    2010-01-01

    Education institutions worldwide have and continue to seek opportunities to spread their offerings abroad. While the provision of courses to students located overseas through partner institutions has many advantages, it raises questions about quality control that are not as applicable to other forms of international education. This paper uses a…

  9. Quality control in a SSDL/NCL

    International Nuclear Information System (INIS)

    Yoloye, O.

    1999-01-01

    The rapid development in nuclear science and technology in particular in radiotherapy and industrial applications of ionizing radiation demands everywhere standardization and permanent control dosimetry. A national calibration laboratory for ionizing radiation must be designated as such by the appropriate authorities. The responsible government authorities should apply the Agency's Radiation Protection Standards and Measures and/or the national ones (when adequate) for the safe use of all kind of ionizing radiation. They should issue to the calibration laboratory a corresponding working licence when the irradiation facilities of the calibration laboratory become operational. The basic aim of a national calibration laboratory is to improve accuracy in radiation dosimetry and should therefore maintain and apply dosimetric equipment of the present state of art, i.e. secondary standards, for calibration of radiation measuring instrumentation for the whole country. It should also undertake measurements and calibrations of the output of radiation sources and installations in the field, whenever this will be required. In addition the calibration laboratory should be the preferred place for receiving training in applied radiation dosimetry. It should give advice to users on up-to-date measurement procedures and techniques. It should promote everywhere the safe application of ionizing radiation by supporting users of ionizing radiation for creation and distribution of better knowledge in the field of applied radiation dosimetry. The strict application of Radiation Protection Standards and Measures will ensure the protection of health and safety of both, the radiation workers and the individuals of the general public, without imposing undue burdens upon the use of ionizing radiation

  10. The role and relevance of quality assurance to quality control

    International Nuclear Information System (INIS)

    Churchill, G.F.

    1989-01-01

    The paper describes the development of Quality Assurance as a total management technique, incorporating manufacturing and construction Quality Control, to give confidence of satisfactory in-service performance. The application of QA to the Heysham 2 and Torness AGR projects design and construction is defined with particular reference to the development of a QA requirements specification, delegation of QA responsibility through the hierarchy of purchasers and suppliers of plant and material, the role of the QA organization and QA auditing. The paper discusses the effectiveness and benefits of QA and the problems identified in its application and implementation. The problems, their solutions and longer term improvements to reduce the costs of QA as well as enhancing confidence in the satisfactory performance of future nuclear projects, are described. (author)

  11. Quality control of PET/CT

    International Nuclear Information System (INIS)

    Angelova, J.; Zajcharov, M.

    2013-01-01

    Full text: Introduction: The aim of this work is to undertake a review of the methods for checking and adjusting the computer and positron emission tomography in the Hospital 'Alexandrovska' by the attached to the equipment phantoms according to the manufacturer prescription in order to fulfill its requirements for the entry of the main parameters image within certain limits. Materials and Methods: At the start of work a check of the lasers setting for patient positioning and 'heat' of the X-ray tube scanner to better image quality were made. Daily verification procedures on the image quality of CT through the water phantom and weekly - 'air' calibration were carried out. In positron part, daily control involves setting the resolution and sensitivity of the scanner through built Ga68 phantom. When commissioning, after repair and at least once a year, it is necessary to verify the accuracy of registration of the pulses from the crystal with a water phantom of known volume and the coincidence between CT and PET image. Results: The process of quality control is interactive. The results are displayed in tables and graphically, with the goal the individual values to fall within the determined by manufacturers range and to meet the standards for image quality. If necessary, the procedure repeats several times until it is fulfilled. Conclusion: Ensuring the quality of the image in positron emission tomography combined with computed tomography, is inextricably linked to accurate and precise diagnosis of tumor processes in the human body

  12. Quality assurance and quality control of nuclear engineering during construction phase

    International Nuclear Information System (INIS)

    Zhang Zhihua; Deng Yue; Liu Yaoguang; Xu Xianqi; Zhou Shan; Qian Dazhi; Zhang Yang

    2007-01-01

    The quality assurance (QA) and quality control (QC) is a very important work in the nuclear engineering. This paper starts with how to establish quality assurance system of nuclear engineering construction phase, then introduces several experiments and techniques such as the implementation of quality assurance program, the quality assurance and quality control of contractors, the quality surveillance and control of supervisory companies, quality assurance audit and surveillance of builders. (authors)

  13. Internal quality control: planning and implementation strategies.

    Science.gov (United States)

    Westgard, James O

    2003-11-01

    The first essential in setting up internal quality control (IQC) of a test procedure in the clinical laboratory is to select the proper IQC procedure to implement, i.e. choosing the statistical criteria or control rules, and the number of control measurements, according to the quality required for the test and the observed performance of the method. Then the right IQC procedure must be properly implemented. This review focuses on strategies for planning and implementing IQC procedures in order to improve the quality of the IQC. A quantitative planning process is described that can be implemented with graphical tools such as power function or critical-error graphs and charts of operating specifications. Finally, a total QC strategy is formulated to minimize cost and maximize quality. A general strategy for IQC implementation is recommended that employs a three-stage design in which the first stage provides high error detection, the second stage low false rejection and the third stage prescribes the length of the analytical run, making use of an algorithm involving the average of normal patients' data.

  14. Quality and Control of Water Vapor Winds

    Science.gov (United States)

    Jedlovec, Gary J.; Atkinson, Robert J.

    1996-01-01

    Water vapor imagery from the geostationary satellites such as GOES, Meteosat, and GMS provides synoptic views of dynamical events on a continual basis. Because the imagery represents a non-linear combination of mid- and upper-tropospheric thermodynamic parameters (three-dimensional variations in temperature and humidity), video loops of these image products provide enlightening views of regional flow fields, the movement of tropical and extratropical storm systems, the transfer of moisture between hemispheres and from the tropics to the mid- latitudes, and the dominance of high pressure systems over particular regions of the Earth. Despite the obvious larger scale features, the water vapor imagery contains significant image variability down to the single 8 km GOES pixel. These features can be quantitatively identified and tracked from one time to the next using various image processing techniques. Merrill et al. (1991), Hayden and Schmidt (1992), and Laurent (1993) have documented the operational procedures and capabilities of NOAA and ESOC to produce cloud and water vapor winds. These techniques employ standard correlation and template matching approaches to wind tracking and use qualitative and quantitative procedures to eliminate bad wind vectors from the wind data set. Techniques have also been developed to improve the quality of the operational winds though robust editing procedures (Hayden and Veldon 1991). These quality and control approaches have limitations, are often subjective, and constrain wind variability to be consistent with model derived wind fields. This paper describes research focused on the refinement of objective quality and control parameters for water vapor wind vector data sets. New quality and control measures are developed and employed to provide a more robust wind data set for climate analysis, data assimilation studies, as well as operational weather forecasting. The parameters are applicable to cloud-tracked winds as well with minor

  15. 42 CFR 84.40 - Quality control plans; filing requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control plans; filing requirements. 84.40... Control § 84.40 Quality control plans; filing requirements. As a part of each application for approval or... proposed quality control plan which shall be designed to assure the quality of respiratory protection...

  16. 21 CFR 211.22 - Responsibilities of quality control unit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Responsibilities of quality control unit. 211.22... Personnel § 211.22 Responsibilities of quality control unit. (a) There shall be a quality control unit that... have been fully investigated. The quality control unit shall be responsible for approving or rejecting...

  17. 30 CFR 28.30 - Quality control plans; filing requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control plans; filing requirements. 28... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.30 Quality control plans; filing... part, each applicant shall file with MSHA a proposed quality control plan which shall be designed to...

  18. Quality Controlling CMIP datasets at GFDL

    Science.gov (United States)

    Horowitz, L. W.; Radhakrishnan, A.; Balaji, V.; Adcroft, A.; Krasting, J. P.; Nikonov, S.; Mason, E. E.; Schweitzer, R.; Nadeau, D.

    2017-12-01

    As GFDL makes the switch from model development to production in light of the Climate Model Intercomparison Project (CMIP), GFDL's efforts are shifted to testing and more importantly establishing guidelines and protocols for Quality Controlling and semi-automated data publishing. Every CMIP cycle introduces key challenges and the upcoming CMIP6 is no exception. The new CMIP experimental design comprises of multiple MIPs facilitating research in different focus areas. This paradigm has implications not only for the groups that develop the models and conduct the runs, but also for the groups that monitor, analyze and quality control the datasets before data publishing, before their knowledge makes its way into reports like the IPCC (Intergovernmental Panel on Climate Change) Assessment Reports. In this talk, we discuss some of the paths taken at GFDL to quality control the CMIP-ready datasets including: Jupyter notebooks, PrePARE, LAMP (Linux, Apache, MySQL, PHP/Python/Perl): technology-driven tracker system to monitor the status of experiments qualitatively and quantitatively, provide additional metadata and analysis services along with some in-built controlled-vocabulary validations in the workflow. In addition to this, we also discuss the integration of community-based model evaluation software (ESMValTool, PCMDI Metrics Package, and ILAMB) as part of our CMIP6 workflow.

  19. Determination and evaluation of air quality control. Manual of ambient air quality control in Germany

    Energy Technology Data Exchange (ETDEWEB)

    Lahmann, E.

    1997-07-01

    Measurement of air pollution emissions and ambient air quality are essential instruments for air quality control. By undertaking such measurements, pollutants are registered both at their place of origin and at the place where they may have an effect on people or the environment. Both types of measurement complement each other and are essential for the implementation of air quality legislation, particularly, in compliance with emission and ambient air quality limit values. Presented here are similar accounts of measurement principles and also contains as an Appendix a list of suitability-tested measuring devices which is based on information provided by the manufacturers. In addition, the guide of ambient air quality control contains further information on discontinuous measurement methods, on measurement planning and on the assessment of ambient air quality data. (orig./SR)

  20. Control of Bank Consolidated Financial Statements Quality

    Directory of Open Access Journals (Sweden)

    Margarita S. Ambarchyan

    2013-01-01

    Full Text Available The author presents the multiple linear regression model of bank consolidated financial statements quality. The article considers six characteristics that can be used to estimate the level of bank consolidated financial statements quality. The multiple linear regression model was developed, using the results of point-based system of consolidated financial statements of thirty European bank and financial groups on the basis of the developed characteristics. The author offers to use the characteristic significance factor in the process of consolidated financial statements appraisal by points. The constructed regression model is checked on accuracy and statistical significance. The model can be used by internal auditors and financial analytics as an instrument for bank and non-bank consolidated financial statements quality control

  1. Wastewater quality control at Sarnia (Ontario, Canada) petrochemical industries

    Energy Technology Data Exchange (ETDEWEB)

    Vianna, Arlinda C. [Servico Nacional de Aprendizagem Industrial (SENAI), Salvador, BA (Brazil); Souza, Eliane S.; Himmelman, William [Lambton College, Sarnia, ON (Canada)

    1993-12-31

    Ontario industries are required by law to meet strict regulations under the provinces under MISA initiative (Municipal-Industrial Strategy for Abatement). The petroleum-petrochemical area was selected as a leader in the development of new environmental objectives, and monitoring and training programs. Sarnia has become a world leader in industrial environmental control systems and the approach toward zero emissions. 4 refs., 6 figs., 2 tabs.

  2. Wastewater quality control at Sarnia (Ontario, Canada) petrochemical industries

    Energy Technology Data Exchange (ETDEWEB)

    Vianna, Arlinda C [Servico Nacional de Aprendizagem Industrial (SENAI), Salvador, BA (Brazil); Souza, Eliane S; Himmelman, William [Lambton College, Sarnia, ON (Canada)

    1994-12-31

    Ontario industries are required by law to meet strict regulations under the provinces under MISA initiative (Municipal-Industrial Strategy for Abatement). The petroleum-petrochemical area was selected as a leader in the development of new environmental objectives, and monitoring and training programs. Sarnia has become a world leader in industrial environmental control systems and the approach toward zero emissions. 4 refs., 6 figs., 2 tabs.

  3. Quality Risk Management: Putting GMP Controls First.

    Science.gov (United States)

    O'Donnell, Kevin; Greene, Anne; Zwitkovits, Michael; Calnan, Nuala

    2012-01-01

    This paper presents a practical way in which current approaches to quality risk management (QRM) may be improved, such that they better support qualification, validation programs, and change control proposals at manufacturing sites. The paper is focused on the treatment of good manufacturing practice (GMP) controls during QRM exercises. It specifically addresses why it is important to evaluate and classify such controls in terms of how they affect the severity, probability of occurrence, and detection ratings that may be assigned to potential failure modes or negative events. It also presents a QRM process that is designed to directly link the outputs of risk assessments and risk control activities with qualification and validation protocols in the GMP environment. This paper concerns the need for improvement in the use of risk-based principles and tools when working to ensure that the manufacturing processes used to produce medicines, and their related equipment, are appropriate. Manufacturing processes need to be validated (or proven) to demonstrate that they can produce a medicine of the required quality. The items of equipment used in such processes need to be qualified, in order to prove that they are fit for their intended use. Quality risk management (QRM) tools can be used to support such qualification and validation activities, but their use should be science-based and subject to as little subjectivity and uncertainty as possible. When changes are proposed to manufacturing processes, equipment, or related activities, they also need careful evaluation to ensure that any risks present are managed effectively. This paper presents a practical approach to how QRM may be improved so that it better supports qualification, validation programs, and change control proposals in a more scientific way. This improved approach is based on the treatment of what are called good manufacturing process (GMP) controls during those QRM exercises. A GMP control can be considered

  4. Microbiological Quality Control of Probiotic Products

    OpenAIRE

    Astashkina, A.P.; Khudyakova, L.I.; Kolbysheva, Y.V.

    2014-01-01

    Microbiological quality control of probiotic products such as Imunele, Dannon, Pomogayka showed that they contain living cultures of the Lactobacillus Bifidobacterium genus in the amount of 107 CFU/ml, which corresponds to the number indicated on the label of products. It is identified that the survival rate of test-strains cultured with pasteurized products does not exceed 10%. The cell concentration of target-microorganisms was reduced by 20-45% after the interaction with living probiotic b...

  5. Mitochondrial quality control in cardiac diseases.

    Directory of Open Access Journals (Sweden)

    Juliane Campos

    2016-10-01

    Full Text Available Disruption of mitochondrial homeostasis is a hallmark of cardiac diseases. Therefore, maintenance of mitochondrial integrity through different surveillance mechanisms is critical for cardiomyocyte survival. In this review, we discuss the most recent findings on the central role of mitochondrial quality control processes including regulation of mitochondrial redox balance, aldehyde metabolism, proteostasis, dynamics and clearance in cardiac diseases, highlighting their potential as therapeutic targets.

  6. Quality control and the multicrystal counter

    International Nuclear Information System (INIS)

    Hart, G.C.; Davis, K.M.

    1983-01-01

    The reliability of multicrystal counters for use in counting large numbers of radioimmunoassay samples is studied. In particular, the dependencies of the outputs from the array of detectors, and hence their degree of matching, on the count rate and volume of the samples being counted are investigated. Quality control procedures are described to assist in the assurance of consistent performance of the counter in the clinical situation. (U.K.)

  7. The software quality control for gamma spectrometry

    International Nuclear Information System (INIS)

    Monte, L.

    1986-01-01

    One of major problems with wich the quality control program of an environmental measurements laboratory is confronted is the evaluation of the performances of software packages for the analysis of gamma-ray spectra. A program of tests for evaluating the performances of the software package (SPECTRAN-F, Canberra Inc.) used by our laboratory is being carried out. In this first paper the results of a preliminary study concerning the evaluation of the performance of the doublet analysis routine are presented

  8. Quality control of estrogen receptor assays.

    Science.gov (United States)

    Godolphin, W; Jacobson, B

    1980-01-01

    Four types of material have been used for the quality control of routine assays of estrogen receptors in human breast tumors. Pieces of hormone-dependent Nb rat mammary tumors gave a precision about 40%. Rat uteri and rat tumors pulverized at liquid nitrogen temperature and stored as powder yielded precision about 30%. Powdered and lyophilised human tumors appear the best with precision as good as 17%.

  9. [Methodological quality and reporting quality evaluation of randomized controlled trials published in China Journal of Chinese Materia Medica].

    Science.gov (United States)

    Yu, Dan-Dan; Xie, Yan-Ming; Liao, Xing; Zhi, Ying-Jie; Jiang, Jun-Jie; Chen, Wei

    2018-02-01

    To evaluate the methodological quality and reporting quality of randomized controlled trials(RCTs) published in China Journal of Chinese Materia Medica, we searched CNKI and China Journal of Chinese Materia webpage to collect RCTs since the establishment of the magazine. The Cochrane risk of bias assessment tool was used to evaluate the methodological quality of RCTs. The CONSORT 2010 list was adopted as reporting quality evaluating tool. Finally, 184 RCTs were included and evaluated methodologically, of which 97 RCTs were evaluated with reporting quality. For the methodological evaluating, 62 trials(33.70%) reported the random sequence generation; 9(4.89%) trials reported the allocation concealment; 25(13.59%) trials adopted the method of blinding; 30(16.30%) trials reported the number of patients withdrawing, dropping out and those lost to follow-up;2 trials (1.09%) reported trial registration and none of the trial reported the trial protocol; only 8(4.35%) trials reported the sample size estimation in details. For reporting quality appraising, 3 reporting items of 25 items were evaluated with high-quality,including: abstract, participants qualified criteria, and statistical methods; 4 reporting items with medium-quality, including purpose, intervention, random sequence method, and data collection of sites and locations; 9 items with low-quality reporting items including title, backgrounds, random sequence types, allocation concealment, blindness, recruitment of subjects, baseline data, harms, and funding;the rest of items were of extremely low quality(the compliance rate of reporting item<10%). On the whole, the methodological and reporting quality of RCTs published in the magazine are generally low. Further improvement in both methodological and reporting quality for RCTs of traditional Chinese medicine are warranted. It is recommended that the international standards and procedures for RCT design should be strictly followed to conduct high-quality trials

  10. Statistical process control for radiotherapy quality assurance

    International Nuclear Information System (INIS)

    Pawlicki, Todd; Whitaker, Matthew; Boyer, Arthur L.

    2005-01-01

    Every quality assurance process uncovers random and systematic errors. These errors typically consist of many small random errors and a very few number of large errors that dominate the result. Quality assurance practices in radiotherapy do not adequately differentiate between these two sources of error. The ability to separate these types of errors would allow the dominant source(s) of error to be efficiently detected and addressed. In this work, statistical process control is applied to quality assurance in radiotherapy for the purpose of setting action thresholds that differentiate between random and systematic errors. The theoretical development and implementation of process behavior charts are described. We report on a pilot project is which these techniques are applied to daily output and flatness/symmetry quality assurance for a 10 MV photon beam in our department. This clinical case was followed over 52 days. As part of our investigation, we found that action thresholds set using process behavior charts were able to identify systematic changes in our daily quality assurance process. This is in contrast to action thresholds set using the standard deviation, which did not identify the same systematic changes in the process. The process behavior thresholds calculated from a subset of the data detected a 2% change in the process whereas with a standard deviation calculation, no change was detected. Medical physicists must make decisions on quality assurance data as it is acquired. Process behavior charts help decide when to take action and when to acquire more data before making a change in the process

  11. The application of strict criminal liabilities to spillage of oil: the practical impact on effective spill response

    International Nuclear Information System (INIS)

    Gallagher, J.J.

    2002-01-01

    The Federal Water Pollution Control Act as amended by the Oil Pollution Act of 1990 provides criminal penalties in oil spills that result from criminal activity, gross negligence or wilful misconduct on the part of the spiller. Nevertheless, the Department of Justice has seen fit to reach into unrelated legislation to potentially apply strict criminal liability to any oil spill regardless of intent. Strict criminalization of accidental oil spills is demonstrably counterproductive to effective protection of the environment from the effect of spills since it poses a serious impediment to cooperation and coordination by and between those charged by law to respond to them. This impediment is particularly dangerous since it threatens the proper functioning of the inherently sensitive ''troika'' Unified Command Structure that has evolved in spill response management in response to OPA-90 management requirements. Introduction of strict criminal liability for accidental spills is also particularly troublesome in that it must enlist unrelated law to influence an area that has been addressed specifically by legislation designed for that purpose; legislation that has worked well in the past 30 years to both regulate the target activities while successfully achieving the objective of protecting and improving environment quality. (author)

  12. 7 CFR 58.642 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.642 Section 58.642... Procedures § 58.642 Quality control tests. All mix ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow line samples as...

  13. 7 CFR 58.928 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be...

  14. 7 CFR 58.335 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.335 Section 58.335... Procedures § 58.335 Quality control tests. All milk, cream and related products are subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow...

  15. Study on the internal quality control of TGAb and TMAb RIA in clinical laboratory

    International Nuclear Information System (INIS)

    Huang Jianrong

    2005-01-01

    To investigate the possible causes of the occasional instability of thyroglobulin anti- body(TGAb) and thyroid microsome antibody (TMAb) detection in the laboratory, the control serums of low, middle, and high value of different batches were measured and the stability of the labeled antigens stored at 2-8 degree C and below zero was observed. The results showed that the maximal variances of high value control serums for TGAb and TMAb between different batches were 33.0% and 32.5%, respectively. This was caused by the changes of titer of second anti- bodies. The labeled antigens stored below zero showed better stability. The strict internal quality control is an efficient measure to improve the measurement precision. (authors)

  16. Development of phantom periapical for control quality

    International Nuclear Information System (INIS)

    Mendes, J.M.S.; Sales Junior, E.S.; Ferreira, F.C.L.; Paschoal, C.M.M.

    2015-01-01

    This study aimed to develop a dental phantom with cysts for evaluation of periapical radiographs that was tested in private dental offices in the city of Maraba, northern Brazil. Through some tests with the object simulator (phantom) were obtained 12 periapical radiographs (one in each of the offices visited) that waking up to the standards of Ordinance No. 453 were visually evaluated by observing the physical parameters of exposure (kVp and mA), time revelation of the radiographic film, later the other radiographs were visually compared with C6 ray set as the default. Among the results, it was found that only two of the twelve rays cysts could not be viewed and, therefore, these two images were deemed unsuitable for accurate diagnosis in the 10 images the cysts could be displayed, however according the images have different qualities comparisons. In addition, it can be concluded that the performance of the phantom was highly satisfactory showing to be efficient for use in quality control testing of dental X-rays, the quality control of radiographs and continuing education of dental professionals for a price much more accessible. (authors)

  17. Quality Management of CERN Vacuum Controls

    CERN Document Server

    Antoniotti, F; Fortescue-Beck, E; Gama, J; Gomes, P; Le Roux, P; Pereira, H; Pigny, G

    2014-01-01

    The vacuum controls Section (TE-VSC-ICM) is in charge of the monitoring, maintenance and consolidation of the control systems of all accelerators and detectors in CERN; this represents 6 000 instruments distributed along 128 km of vacuum chambers, often of heterogeneous architectures and of diverse technical generations. In order to improve the efficiency of the services provided by ICM, to vacuum experts and to accelerator operators, a Quality Management Plan is being put into place. The first step was the standardization of the naming convention across different accelerators. The traceability of problems, requests, repairs, and other actions, has also been put into place (VTL). This was combined with the effort to identify each individual device by a coded label, and register it in a central database (MTF). Occurring in parallel, was the gathering of old documents and the centralization of information concerning architectures, procedures, equipment and settings (EDMS). To describe the topology of control c...

  18. Microbiological quality control practices at Australian Radioisotopes

    International Nuclear Information System (INIS)

    Saunders, M.

    1987-01-01

    As a domestic manufacturer of therapeutic substances, Australian Radioisotopes (ARI) must adhere to guidelines set out by the Commonwealth Department of Health in the Code of Good Manufacturing Practices for Therapeutic Goods 1983 (GMP). The GMP gives guidelines for staff training, building requirements, sanitation, documentation and quality control practices. These guidelines form the basis for regular audits performed by officers of the National Biological Standards Laboratories. At Lucas Heights, ARI has combined the principles of the GMP with the overriding precautions introduced for environmental and staff safety and protection. Its policy is to maintain a high level of quality assurance for product identity, purity and sterility and apyrogenicity during all stages of product manufacture

  19. Basic quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Wikstrom, Erik

    2016-01-01

    Along the route toward regular performance of Quality Control in the Diagnostic Imaging sector there are a number of balances to negotiate: Patient/Staff safety considerations vs Regulatory compliance vs Performance of modern equipment vs Clinic's Productivity. At first glance these ambitions may seem in conflict. The tests performed to meet regulatory requirements may or may not bear any semblance to real clinical measurement scenarios. And the process of collecting the data from the quality assurance tests may induce a system down- time that adversely affects the clinic's overall productivity. Furthermore, the time it takes to complete the analysis of the test data and provide the report required to take the facility back into operation is time wasted for patients waiting for a diagnostic imaging exam

  20. ANALYSIS OF QUALITY COSTS FOR STATISTICA QUALITY CONTROL PLANNING

    Directory of Open Access Journals (Sweden)

    N. Chiadamrong

    2017-12-01

    Full Text Available Quality has become one or the most important force leading to organizational success and company growth in national and international markets. The return-on-investment from strong and effective quality programs is providing excellent profitability results in firms with effective quality strategies. Due to the wide variation in quality results, the search for the genuine keys to success in quality has become a matter of deep concern to management of companies. This paper suggests a way to quantifying quality costs. As a result, the appropriate quality strategies can be adjusted and set to match with each company situation based on the categorization of the quality costs suggested. This outcome can, then, be used as a guideline for manufactures in setting their suitable quality program, which establishes the proper balance between the costs and customer services.

  1. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Science.gov (United States)

    2010-07-01

    ... quality assurance audit or any other audit, the system is out-of-control. The owner or operator shall... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner or...

  2. Distributed sensor architecture for intelligent control that supports quality of control and quality of service.

    Science.gov (United States)

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-02-25

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  3. Distributed Sensor Architecture for Intelligent Control that Supports Quality of Control and Quality of Service

    Directory of Open Access Journals (Sweden)

    Jose-Luis Poza-Lujan

    2015-02-01

    Full Text Available This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS parameters and the optimization of control using Quality of Control (QoC parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS communication standard as proposed by the Object Management Group (OMG. As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  4. Quality control in quantitative computed tomography

    International Nuclear Information System (INIS)

    Jessen, K.A.; Joergensen, J.

    1989-01-01

    Computed tomography (CT) has for several years been an indispensable tool in diagnostic radiology, but it is only recently that extraction of quantitative information from CT images has been of practical clinical value. Only careful control of the scan parameters, and especially the scan geometry, allows useful information to be obtained; and it can be demonstrated by simple phantom measurements how sensitive a CT system can be to variations in size, shape and position of the phantom in the gantry aperture. Significant differences exist between systems that are not manifested in normal control of image quality and general performance tests. Therefore an actual system has to be analysed for its suitability for quantitative use of the images before critical clinical applications are justified. (author)

  5. Quality control concept for radioactive waste packages

    International Nuclear Information System (INIS)

    Warnecke, E.; Martens, B.R.; Odoj, R.

    1990-01-01

    In the Federal Republic of Germany a contract with the BfS for the performance of quality control measures is necessary. It is principally possible to apply two alternative methods: random checks on waste packages or qualification of conditioning processes with subsequent inspections. Priority is given to the control by the process qualification. Both methods have successfully been developed in the Federal Republic of Germany and can be applied. In the course of the qualification of conditioning processes it must be demonstrated by inactive and/or active runs that waste packages are produced which fulfil the waste acceptance requirements. The qualification results in the fixation of a handbook for the operation of the respective conditioning process including the process instrumentation and the operational margins. The qualified process will be inspected to assure the compliance of the actual operation with the conditions fixed in the handbook. (orig./DG)

  6. Modal Inclusion Logic: Being Lax is Simpler than Being Strict

    DEFF Research Database (Denmark)

    Hella, Lauri; Kuusisto, Antti Johannes; Meier, Arne

    2015-01-01

    We investigate the computational complexity of the satisfiability problem of modal inclusion logic. We distinguish two variants of the problem: one for strict and another one for lax semantics. The complexity of the lax version turns out to be complete for EXPTIME, whereas with strict semantics...

  7. 7 CFR 28.426 - Strict Good Ordinary Spotted Color.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strict Good Ordinary Spotted Color. 28.426 Section 28.426 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... Spotted Color. Strict Good Ordinary Spotted Color is color which is within the range represented by a set...

  8. 7 CFR 28.433 - Strict Low Middling Tinged Color.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strict Low Middling Tinged Color. 28.433 Section 28.433 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... Tinged Color. Strict Low Middling Tinged Color is color which is within the range represented by a set of...

  9. 7 CFR 28.422 - Strict Middling Spotted Color.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strict Middling Spotted Color. 28.422 Section 28.422 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... Color. Strict Middling Spotted Color is color which is within the range represented by a set of samples...

  10. 7 CFR 28.424 - Strict Low Middling Spotted Color.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strict Low Middling Spotted Color. 28.424 Section 28.424 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... Spotted Color. Strict Low Middling Spotted Color is color which is within the range represented by a set...

  11. 7 CFR 28.431 - Strict Middling Tinged Color.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Strict Middling Tinged Color. 28.431 Section 28.431 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... Color. Strict Middling Tinged Color is color which is better than Middling Tinged Color. ...

  12. 43 CFR 29.7 - Imposition of strict liability.

    Science.gov (United States)

    2010-10-01

    ... LIABILITY FUND § 29.7 Imposition of strict liability. (a) Notwithstanding the provisions of any other law... prove that the damages were caused by an act of war or by the negligence of the United States or other... negligence of such damaged party. (c)(1) Strict liability for all claims arising out of any one incident...

  13. Strictly-regular number system and data structures

    DEFF Research Database (Denmark)

    Elmasry, Amr Ahmed Abd Elmoneim; Jensen, Claus; Katajainen, Jyrki

    2010-01-01

    We introduce a new number system that we call the strictly-regular system, which efficiently supports the operations: digit-increment, digit-decrement, cut, concatenate, and add. Compared to other number systems, the strictly-regular system has distinguishable properties. It is superior to the re...

  14. STRICT CONVEXITY THROUGH EQUIVALENT NORMS IN SEPARABLES BANACH SPACES

    Directory of Open Access Journals (Sweden)

    Willy Zubiaga Vera

    2016-12-01

    Full Text Available Let E be a separable Banach space with norm || . ||. In the present work, the objective is to construct a norm || . ||1 that is equivalent to || . || in E, such that || . ||1 is strictly convex. In addition it is shown that its dual conjugate norm is also strictly convex.

  15. Software Quality Control at Belle II

    Science.gov (United States)

    Ritter, M.; Kuhr, T.; Hauth, T.; Gebard, T.; Kristof, M.; Pulvermacher, C.; Belle Software Group, II

    2017-10-01

    Over the last seven years the software stack of the next generation B factory experiment Belle II has grown to over one million lines of C++ and Python code, counting only the part included in offline software releases. There are several thousand commits to the central repository by about 100 individual developers per year. To keep a coherent software stack of high quality that it can be sustained and used efficiently for data acquisition, simulation, reconstruction, and analysis over the lifetime of the Belle II experiment is a challenge. A set of tools is employed to monitor the quality of the software and provide fast feedback to the developers. They are integrated in a machinery that is controlled by a buildbot master and automates the quality checks. The tools include different compilers, cppcheck, the clang static analyzer, valgrind memcheck, doxygen, a geometry overlap checker, a check for missing or extra library links, unit tests, steering file level tests, a sophisticated high-level validation suite, and an issue tracker. The technological development infrastructure is complemented by organizational means to coordinate the development.

  16. Quality control of nuclear medicine instruments

    International Nuclear Information System (INIS)

    1984-11-01

    This document, which gives detailed guidance on the quality control of the various electronic instruments used for radiation detection and measurement in nuclear medicine, stems from the work of two Advisory Groups convened by the International Atomic Energy Agency (IAEA). A preliminary document, including recommended test schedules but lacking actual protocols for the tests, was drawn up by the first of these groups, meeting at the IAEA Headquarters in Vienna in 1979. A revised and extended version, incorporating recommended test protocols, was prepared by the second Group, meeting likewise in Vienna in 1982. This version is the model for the present text. The document should be of value to all nuclear medicine units, and especially to those in developing countries, in the initiation or revision of schemes for the quality control of their instruments. Its recommendations have provided the basis for instruction in two IAEA regional technical co-operation projects in the subject field, one initiated in 1981 for countries of Latin America and one initiated in 1982 for countries of Asia and the Pacific

  17. Toward standardising gamma camera quality control procedures

    International Nuclear Information System (INIS)

    Alkhorayef, M.A.; Alnaaimi, M.A.; Alduaij, M.A.; Mohamed, M.O.; Ibahim, S.Y.; Alkandari, F.A.; Bradley, D.A.

    2015-01-01

    Attaining high standards of efficiency and reliability in the practice of nuclear medicine requires appropriate quality control (QC) programs. For instance, the regular evaluation and comparison of extrinsic and intrinsic flood-field uniformity enables the quick correction of many gamma camera problems. Whereas QC tests for uniformity are usually performed by exposing the gamma camera crystal to a uniform flux of gamma radiation from a source of known activity, such protocols can vary significantly. Thus, there is a need for optimization and standardization, in part to allow direct comparison between gamma cameras from different vendors. In the present study, intrinsic uniformity was examined as a function of source distance, source activity, source volume and number of counts. The extrinsic uniformity and spatial resolution were also examined. Proper standard QC procedures need to be implemented because of the continual development of nuclear medicine imaging technology and the rapid expansion and increasing complexity of hybrid imaging system data. The present work seeks to promote a set of standard testing procedures to contribute to the delivery of safe and effective nuclear medicine services. - Highlights: • Optimal parameters for quality control of the gamma camera are proposed. • For extrinsic and intrinsic uniformity a minimum of 15,000 counts is recommended. • For intrinsic flood uniformity the activity should not exceed 100 µCi (3.7 MBq). • For intrinsic uniformity the source to detector distance should be at least 60 cm. • The bar phantom measurement must be performed with at least 15 million counts.

  18. Performance and quality control of scintillation cameras

    International Nuclear Information System (INIS)

    Moretti, J.L.; Iachetti, D.

    1983-01-01

    Acceptance testing, quality and control assurance of gamma-cameras are a part of diagnostic quality in clinical practice. Several parameters are required to achieve a good diagnostic reliability: intrinsic spatial resolution, spatial linearity, uniformities, energy resolution, count-rate characteristics, multiple window spatial analysis. Each parameter was measured and also estimated by a test easy to implement in routine practice. Material required was a 4028 multichannel analyzer linked to a microcomputeur, mini-computers and a set of phantoms (parallel slits, diffusing phantom, orthogonal hole transmission pattern). Gamma-cameras on study were:CGR 3400, CGR 3420, G.E.4000. Siemens ZLC 75 and large field Philips. Several tests proposed by N.E.M.A. and W.H.O. have to be improved concerning too punctual spatial determinations during distortion measurements with multiple window. Contrast control of image need to be monitored with high counting rate. This study shows the need to avoid punctual determinations and the interest to give sets of values of the same parameter on the whole field and to report mean values with their standard variation [fr

  19. Quality control of radioiodinated gastrin for radioimmunoassay

    International Nuclear Information System (INIS)

    Ginabreda, M.G.P.; Borghi, V.C.; Bettarello, A.

    1988-07-01

    Radioiodinated human gastrin has been prepared at IPEN laboratory for radioimmunoassay use. This work developed the quality control of this tracer analyzing parameters of the labelling reaction, chromatographic purification and radioimmunoassay. The radioiodination yield obtained in five experiments was reproducible and similar when analyzed on 7% polyaraylamide gel eletrophoresis - PAGE - (mean + - SD of 51.70 + - 10.76%) and by1 25 I incorporation checked through thrichloroacetic acid precipitation - TCA - (57-36 + - 9.69%). Similary, after purification the labelled gastrin revaled high and reproducible purity degree when submitted to PAGE (96.57 + - 1.06%) and CA (94.82 + - 4.20%) analysis. The respective specific activities varied from 62 to 307 uCi/ug, being determined by the self-displacement method, which is based on the immunoactivity of the tracer. In this way, the antibody titers required to bind 50% of the tracer ranged from 1:32.000 to 1:180.000. Consequently, the respective doses producing 50% fall in the maximum response of the radioimmunoassays ranged from 155.0 to 24.0 pmol/1, but remained unchanged for each tracer even after three months of its preparations. The tracers presented very low non-specific binding values (1.78 + - 0.79%), stablespecific binding values (46.49 + - 5.65%) and a good between-assay precision, evaluated by an internal quality control sample (25.71 + - 4.30%) with coefficient of variation of 16.74%). The PAGE analysis of the unlabeled gastrin used in the first and last radioiodination revealed an unique and unaltered component, confirming the quality of the tracers. (author) [pt

  20. 7 CFR 58.141 - Alternate quality control program.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Alternate quality control program. 58.141 Section 58... Service 1 Quality Specifications for Raw Milk § 58.141 Alternate quality control program. When a plant has in operation an acceptable quality program, at the producer level, which is approved by the...

  1. Technology requirement for Halal quality control | Husny | Journal of ...

    African Journals Online (AJOL)

    Technology requirement for Halal quality control. ... Findings show that each industry segments have different technology characteristics preference. ... Keywords: halal industry, quality control; technology assistance; food and beverage; ...

  2. Environmental radiation control and quality management system in design and operation of sealed radioactive sources

    International Nuclear Information System (INIS)

    Hussein, A.Z.

    2007-01-01

    New environmental regulations and radiation safety standards are being implemented almost daily to ensure radiation safety, in particular for practices causing exposures to undue radiation doses. A particular emphasis of real challenge for organizations and users of radiation sources has to be for proper radiological safety assessment and is becoming cost effectively to be prepared for auditing. Special concern for the environment is of global . nature, and hence environmental auditing has been and will continue to be an essential practice for improving the environment and for meeting the relevant regulations and standards. In general, most facilities that deal with radioactive sources undertake strict safety measures in terms of personnel radiation protection, handling procedures and security. Hence, those measures should comply with the requirements of the environmental protection standards. Accordingly, a successful quality management system must balance realities of organization and personnel in achieving quality objectives. Organizational principles are found in the technical aspects of' quality management, such as, charting, requirements, measurements, procedures, ... , etc. Human principles are found in the communication side of quality management (e.g. meetings, ,decision making, ,teams, ... , etc). The quality management must understand and balance skills needed to blend them together. Large gamma irradiators present a high potential radiation hazard to the surrounding environment, since the amount of radioactivity is of the order of (P Bq) and a very high dose rates are produced during irradiation. Application of environmental radiation control deemed by regulatory authority and a proper quality management system by the utility would serve public health and safety

  3. Managing Air Quality - Control Strategies to Achieve Air Pollution Reduction

    Science.gov (United States)

    Considerations in designing an effective control strategy related to air quality, controlling pollution sources, need for regional or national controls, steps to developing a control strategy, and additional EPA resources.

  4. 10 CFR 26.137 - Quality assurance and quality control.

    Science.gov (United States)

    2010-01-01

    ... cutoff concentration for the compound of interest, a control without the compound of interest (i.e., a certified negative control), and a control with at least one of the compounds of interest at a measurable... calibrator, a control without the compound of interest (i.e., a certified negative control), and a control...

  5. 14 CFR 21.147 - Changes in quality control system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Changes in quality control system. 21.147 Section 21.147 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... quality control system. After the issue of a production certificate, each change to the quality control...

  6. 14 CFR 145.211 - Quality control system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to...

  7. 7 CFR 58.523 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  8. 18 CFR 12.40 - Quality control programs.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Quality control... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a... meeting any requirements or standards set by the Regional Engineer. If a quality control program is...

  9. 21 CFR 640.56 - Quality control test for potency.

    Science.gov (United States)

    2010-04-01

    ... quality control test for potency may be performed by a clinical laboratory which meets the standards of... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Quality control test for potency. 640.56 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.56 Quality control...

  10. Quality control of ATLAS muon chambers

    CERN Document Server

    Fabich, Adrian

    ATLAS is a general-purpose experiment for the future Large Hadron Collider (LHC) at CERN. Its Muon Spectrometer will require ∼ 5500m2 of precision tracking chambers to measure the muon tracks along a spectrometer arm of 5m to 15m length, embedded in a magnetic field of ∼ 0.5T. The precision tracking devices in the Muon System will be high pressure drift tubes (MDTs). Approximately 370,000 MDTs will be assembled into ∼ 1200 drift chambers. The performance of the MDT chambers is very much dependent on the mechanical quality of the chambers. The uniformity and stability of the performance can only be assured providing very high quality control during production. Gas tightness, high-voltage behaviour and dark currents are global parameters which are common to gas detectors. For all chambers, they will be tested immediately after the chamber assembly at every production site. Functional tests, for example radioactive source scans and cosmic-ray runs, will be performed in order to establish detailed performan...

  11. Acceptance, commissioning and quality control in radiosurgery

    International Nuclear Information System (INIS)

    Toreti, Dalila Luzia

    2009-01-01

    Stereotactic Radiosurgery is a treatment technique that uses narrow beams of radiation focused with great accuracy in a small lesion. The introduction of micro multi leaf collimators (mMLC) allows this technique to reach a higher degree of dose conformation of the target lesion allowing a smaller irradiation of critical structures and normal tissues. This paper presents the results of the acceptance tests and commissioning of a Varian 6EX linear accelerator dedicated to radiosurgery associated with the BrainLab micro multi leaf collimator installed in the Hospital das Clinicas da Faculdade de Medicina da USP (HC-FMUSP) and establish feasible quality assurance program for the services that employ this special technique. The results of the acceptance tests were satisfactory and are willing with the specifications provided by the manufacturer and the commissioning tests were within the international recommendations. The tests and measures that are part of quality control process should be specific to each treatment unit, and the need, frequency and levels of tolerance

  12. Quality control in nuclear fuel fabrication

    International Nuclear Information System (INIS)

    Abdelhalim, A.S.; Elsayed, A.A.; Shaaban, H.I.

    1988-01-01

    The department of metallurgy, NRC Inchass is embarking on a programme of on a laboratory scale, fuel pins containing uranium dioxide pellets are going to be produced. The department is making use of the expertise and equipment at present available and is going to utilize the new fuel pin fabrication unit which would be shortly in operation. The fabrication and testing of uranium dioxide pellets then gradually adapt them and develop, a national know how in this field. This would also involve building up of indigenous experience through proper training of qualified personnel. That are applied to ensure quality of U o 2 pellets, the techniques implemented, the equipment used and the specifications of the equipment presently available. The following parameters are subject to quality control tests: density. O/U ration, hydrogen content, microstructure, each property will be discussed, measurements related to U o 2 powders, including flow ability, bulk density, O/U ratio, bet surface area and water content will be critically discussed. Relevant tests to ensure Q C of pellets are reviewed. These include surface integrity, density, dimensions, microstructure.4 fig., 1 tab

  13. Tools for quality control of fingerprint databases

    Science.gov (United States)

    Swann, B. Scott; Libert, John M.; Lepley, Margaret A.

    2010-04-01

    Integrity of fingerprint data is essential to biometric and forensic applications. Accordingly, the FBI's Criminal Justice Information Services (CJIS) Division has sponsored development of software tools to facilitate quality control functions relative to maintaining its fingerprint data assets inherent to the Integrated Automated Fingerprint Identification System (IAFIS) and Next Generation Identification (NGI). This paper provides an introduction of two such tools. The first FBI-sponsored tool was developed by the National Institute of Standards and Technology (NIST) and examines and detects the spectral signature of the ridge-flow structure characteristic of friction ridge skin. The Spectral Image Validation/Verification (SIVV) utility differentiates fingerprints from non-fingerprints, including blank frames or segmentation failures erroneously included in data; provides a "first look" at image quality; and can identify anomalies in sample rates of scanned images. The SIVV utility might detect errors in individual 10-print fingerprints inaccurately segmented from the flat, multi-finger image acquired by one of the automated collection systems increasing in availability and usage. In such cases, the lost fingerprint can be recovered by re-segmentation from the now compressed multi-finger image record. The second FBI-sponsored tool, CropCoeff was developed by MITRE and thoroughly tested via NIST. CropCoeff enables cropping of the replacement single print directly from the compressed data file, thus avoiding decompression and recompression of images that might degrade fingerprint features necessary for matching.

  14. Quality control tests for conventional mammography

    International Nuclear Information System (INIS)

    Dawod, Alnazer Ahmed Ibrahim

    2014-12-01

    Mammography is this the test that allows the radiologist to look at images of the inside of the breasts. Mammograms help detect breast cancer early successful treatment of breast cancer depends on that early diagnosis. Breast cancer is a very common condition. About one in every nine women develops breast cancer by the age of eighty. In addition to the clinical examination and self-examination, mammography plays important role in the detection of breast cancer before they become clinically visible tumors. The mammography is the most common test for early detection of breast cancer. Quality control techniques that done ensured importance of this programme to produce images with good diagnostic values and help radiologist to diagnose breast discase easily and avoid exposing patient to radiation hazards.(Author)

  15. Analytical quality control [An IAEA service

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1973-07-01

    In analytical chemistry the determination of small or trace amounts of elements or compounds in different types of materials is increasingly important. The results of these findings have a great influence on different fields of science, and on human life. Their reliability, precision and accuracy must, therefore, be checked by analytical quality control measures. The International Atomic Energy Agency (IAEA) set up an Analytical Quality Control Service (AQCS) in 1962 to assist laboratories in Member States in the assessment of their reliability in radionuclide analysis, and in other branches of applied analysis in which radionuclides may be used as analytical implements. For practical reasons, most analytical laboratories are not in a position to check accuracy internally, as frequently resources are available for only one method; standardized sample material, particularly in the case of trace analysis, is not available and can be prepared by the institutes themselves only in exceptional cases; intercomparisons are organized rather seldom and many important types of analysis are so far not covered. AQCS assistance is provided by the shipment to laboratories of standard reference materials containing known quantities of different trace elements or radionuclides, as well as by the organization of analytical intercomparisons in which the participating laboratories are provided with aliquots of homogenized material of unknown composition for analysis. In the latter case the laboratories report their data to the Agency's laboratory, which calculates averages and distributions of results and advises each laboratory of its performance relative to all the others. Throughout the years several dozens of intercomparisons have been organized and many thousands of samples provided. The service offered, as a consequence, has grown enormously. The programme for 1973 and 1974, which is currently being distributed to Member States, will contain 31 different types of materials.

  16. The growing need for analytical quality control

    International Nuclear Information System (INIS)

    Suschny, O.; Richman, D.M.

    1974-01-01

    Technological development in a country is directly dependent upon its analytical chemistry or measurement capability, because it is impossible to achieve any level of technological sophistication without the ability to measure. Measurement capability is needed to determine both technological competence and technological consequence. But measurement itself is insufficient. There must be a standard or a reference for comparison. In the complicated world of chemistry the need for reference materials grows with successful technological development. The International Atomic Energy Agency has been distributing calibrated radioisotope solutions, standard reference materials and intercomparison materials since the early 1960's. The purpose of this activity has been to help laboratories in its Member States to assess and, if necessary, to improve the reliability of their analytical work. The value and continued need of this service has been demonstrated by the results of many intercomparisons which proved that without continuing analytical quality control activities, adequate reliability of analytical data could not be taken for granted. Analytical chemistry, lacking the glamour of other aspects of the physical sciences, has not attracted the attention it deserves, but in terms of practical importance, it warrants high priority in any developing technological scheme, because without it there is little chance to evaluate technological success or failure or opportunity to identify the reasons for success or failure. The scope and the size of the future programme of the IAEA in this field has been delineated by recommendations made by several Panels of Experts; all have agreed on the importance of this programme and made detailed recommendations in their areas of expertise. The Agency's resources are limited and it cannot on its own undertake the preparation and distribution of all the materials needed. It can, however, offer a focal point to bring together different

  17. Terms and definitions of quality assurance/quality control

    International Nuclear Information System (INIS)

    Kaden, W.

    1980-01-01

    Terms of quality assurance are defined and interpreted. Reference is made to the IAEA Code of Practice and to other important Codes and Standards like ANSI, ASME and KTA. The relevance of these terms to everyday's work and problems of a quality assurance engineer is explained. (orig.)

  18. [Compatibility of different quality control systems].

    Science.gov (United States)

    Invernizzi, Enrico

    2002-01-01

    Management of the good laboratory practice (GLP) quality system presupposes its linking to a basic recognized and approved quality system, from which it can draw on management procedures common to all quality systems, such as the ISO 9000 set of norms. A quality system organized in this way can also be integrated with other dedicated quality systems, or parts of them, to obtain principles or management procedures for specific topics. The aim of this organization is to set up a reliable, recognized quality system compatible with the principles of GLP and other quality management systems, which provides users with a simplified set of easily accessible management tools and answers. The organization of this quality system is set out in the quality assurance programme, which is actually the document in which the test facility incorporates the GLP principles into its own quality organization.

  19. Requirements for quality control of analytical data

    International Nuclear Information System (INIS)

    Westmoreland, R.D.; Bartling, M.H.

    1990-07-01

    The National Contingency Plan (NCP) of the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) provides procedures for the identification, evaluation, and remediation of past hazardous waste disposal sites. The Hazardous Materials Response section of the NCP consists of several phases: Preliminary Assessment, Site Inspection, Remedial Investigation, Feasibility Study, Remedial Design, and Remedial Action. During any of these phases, analysis of soil, water, and waste samples may be performed. The Hazardous Waste Remedial Actions Program (HAZWRAP) is involved in performing field investigations and sample analyses pursuant to the NCP for the US Department of Energy and other federal agencies. The purpose of this document is to specify the requirements of Martin Marietta Energy Systems, Inc., for the control of accuracy, precision, and completeness of samples and data from the point of collection through analysis. Requirements include data reduction and reporting of resulting environmentally related data. Because every instance and concern may not be addressed in this document, HAZWRAP subcontractors are encouraged to discuss any questions with the Analytical Quality Control Specialist (AQCS) and the HAZWRAP Project Manager. This revision supercedes all other versions of this document

  20. Normal form and synchronization of strict-feedback chaotic systems

    International Nuclear Information System (INIS)

    Wang, Feng; Chen, Shihua; Yu Minghai; Wang Changping

    2004-01-01

    This study concerns the normal form and synchronization of strict-feedback chaotic systems. We prove that, any strict-feedback chaotic system can be rendered into a normal form with a invertible transform and then a design procedure to synchronize the normal form of a non-autonomous strict-feedback chaotic system is presented. This approach needs only a scalar driving signal to realize synchronization no matter how many dimensions the chaotic system contains. Furthermore, the Roessler chaotic system is taken as a concrete example to illustrate the procedure of designing without transforming a strict-feedback chaotic system into its normal form. Numerical simulations are also provided to show the effectiveness and feasibility of the developed methods

  1. Strict finitism and the logic of mathematical applications

    CERN Document Server

    Ye, Feng

    2011-01-01

    Exploring the logic behind applied mathematics to the physical world, this volume illustrates how radical naturalism, nominalism and strict finitism can account for the applications of classical mathematics in current theories about natural phenomena.

  2. Minimal requirements for quality controls in radiotherapy with external beams; Controlli di qualita' essenziali in radioterapia con fasci esterni

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    Physical dosimetric guidelines have been developed by the Italian National Institute of Health study group on quality assurance in radiotherapy to define protocols for quality controls in external beam radiotherapy. While the document does not determine strict rules or firm recommendations, it suggests minimal requirements for quality controls necessary to guarantee an adequate degree of accuracy in external beam radiotherapy. [Italian] Il gruppo di studio Assicurazione di qualita' in radioterapia dell'Istituto Superiore di Sanita' presenta le linee guida per la stesura dei protocolli di controllo di qualita' essenziali necessari a garantire un adeguato livello di accuratezza del trattamento radiante e rappresenta pertanto una parte essenziale del contributo fisico-dosimetrico globale di assicurazione di qualita' in radioterapia con fasci esterni.

  3. Control of surface quality of sub-millimeter cylindrical gold targets

    International Nuclear Information System (INIS)

    Zhang Yunwang; Du Kai; Wan Xiaobo; Xiao Jiang; Zheng Wei; Zhang Lin; Sun Jingyuan; Chen Jing

    2010-01-01

    The morphology, composition and causes of defects are analyzed to reduce defects on the gold layer prepared by electrochemical deposition from sulfite solution, and to improve the surface quality of sub-millimeter cylindrical gold targets, by means of SEM and EDS. The effects of current density, metallic impurity, organic pollution, pre-deposition parameters and mandrel quality on the quality of the gold plating are discussed, along with their mechanisms. The result indicates that the current density must be controlled strictly. The optimal current density ranges from 2.4 to 3.2 mA/cm 2 when the concentration of gold ranges from 13 to 22 g/L, and from 2.0 to 2.6 mA/ cm 2 when the concentration of gold ranges from 5 to 13 g/L. The parameters of predeposition must be optimized and the predeposition time should be no longer than 1 minute to improve the surface quality. In addition, organic pollution should be removed from the bath, and the mandrels should be of good quality without oxide on their surfaces. (authors)

  4. Chapter 5: Quality assurance/quality control in stormwater sampling

    Science.gov (United States)

    Sampling the quality of stormwater presents unique challenges because stormwater flow is relatively short-lived with drastic variability. Furthermore, storm events often occur with little advance warning, outside conventional work hours, and under adverse weather conditions. Therefore, most stormwat...

  5. Two examples of non strictly convex large deviations

    OpenAIRE

    De Marco, Stefano; Jacquier, Antoine; Roome, Patrick

    2016-01-01

    We present two examples of a large deviations principle where the rate function is not strictly convex. This is motivated by a model used in mathematical finance (the Heston model), and adds a new item to the zoology of non strictly convex large deviations. For one of these examples, we show that the rate function of the Cramer-type of large deviations coincides with that of the Freidlin-Wentzell when contraction principles are applied.

  6. 21 CFR 111.117 - What quality control operations are required for equipment, instruments, and controls?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for equipment, instruments, and controls? 111.117 Section 111.117 Food and Drugs FOOD AND DRUG ADMINISTRATION... and Process Control System: Requirements for Quality Control § 111.117 What quality control operations...

  7. Strictly contractive quantum channels and physically realizable quantum computers

    International Nuclear Information System (INIS)

    Raginsky, Maxim

    2002-01-01

    We study the robustness of quantum computers under the influence of errors modeled by strictly contractive channels. A channel T is defined to be strictly contractive if, for any pair of density operators ρ, σ in its domain, parallel Tρ-Tσ parallel 1 ≤k parallel ρ-σ parallel 1 for some 0≤k 1 denotes the trace norm). In other words, strictly contractive channels render the states of the computer less distinguishable in the sense of quantum detection theory. Starting from the premise that all experimental procedures can be carried out with finite precision, we argue that there exists a physically meaningful connection between strictly contractive channels and errors in physically realizable quantum computers. We show that, in the absence of error correction, sensitivity of quantum memories and computers to strictly contractive errors grows exponentially with storage time and computation time, respectively, and depends only on the constant k and the measurement precision. We prove that strict contractivity rules out the possibility of perfect error correction, and give an argument that approximate error correction, which covers previous work on fault-tolerant quantum computation as a special case, is possible

  8. An Austrian framework for PET quality control

    International Nuclear Information System (INIS)

    Nicoletti, R.; Dobrozemsky, G.; Minear, G.; Bergmann, H.

    2002-01-01

    Full text: The European patient protection directive (97/43 EURATOM) requires regular routine quality control (QC) of PET imaging devices. Since no standards were available covering this area and in order to comply with the directive a joint working party of the Austrian societies of nuclear medicine and of medical physics have developed a set of procedures suitable for both dedicated PET scanners and gamma cameras operating in coincidence mode (GCPET). The routine procedures proposed include both manufacturer recommended procedures and tests for specific parameters and calibration procedures. Wherever possible, procedures adapted or derived from NEMA standards publication NU 2-2001 were used to permit direct comparison with specified parameters of image quality. For dedicated PET scanners the most important procedures are the checking of detector sensitivities and the attenuation calibration scan. With full ring scanners the attenuation calibration scan is a blank scan, with partial ring devices a special attenuation calibration phantom has to be used. Test protocols are specific to manufacturer and scanner type. They are usually performed automatically overnight. In addition, some instruments require special calibrations, e.g. gain adjustments or coincidence timing calibration. GCPET procedures include the frequent assessment in coincidence mode of detector uniformity, energy resolution and system sensitivity. Common to both dedicated PET and GCPET are the regular quarterly assessment of tomographic spatial resolution and the calibration of the system for quantitative measurements. As a total performance test for both systems assessment of image quality following NU 2-2001 was included, to be carried out after major system changes or repairs. The suite of QC procedures was tested on several dedicated PET and GCPET systems including all major manufacturers' systems. Due to missing hardware or software not all tests could be performed on all systems. Some of the

  9. Quality control and characterization of bentonite materials

    International Nuclear Information System (INIS)

    Kiviranta, L.; Kumpulainen, S.

    2011-12-01

    . Thus, in a certain extent, index tests can be used to determine the smectite content indicatively for quality control purposes. Previously set acceptance testing requirement limits for swelling index, liquid limit and CEC should be reconsidered, since Ca-bentonite tested in this study did not fulfill the requirement for swelling index, the previously set liquid limit requirement value was way below the values measured in this study, and because the previously set CEC requirement limits were based on a technique that needed different requirement limits for Na- and Ca-bentonites, on contrary to the method used in this study.(orig.)

  10. 7 CFR 58.733 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.733 Section 58.733... Procedures § 58.733 Quality control tests. (a) Chemical analyses. The following chemical analyses shall be... pasteurization by means of the phosphatase test, as well as any other tests necessary to assure good quality...

  11. Performance and quality control of nuclear medicine instrumentation

    International Nuclear Information System (INIS)

    Paras, P.

    1981-01-01

    The status and the recent developments of nuclear medicine instrumentation performance, with an emphasis on gamma-camera performance, are discussed as the basis for quality control. New phantoms and techniques for the measurement of gamma-camera performance parameters are introduced and their usefulness for quality control is discussed. Tests and procedures for dose calibrator quality control are included. Also, the principles of quality control, tests, equipment and procedures for each type of instrument are reviewed, and minimum requirements for an effective quality assurance programme for nuclear medicine instrumentation are suggested. (author)

  12. 10 CFR 26.167 - Quality assurance and quality control.

    Science.gov (United States)

    2010-01-01

    ... at the appropriate cutoff concentration for the compound of interest as specified in § 26.161(c) and (f), a control without the compound of interest (i.e., a certified negative control), and at least one control with one of the compounds of interest at a measurable concentration; and (ii) A...

  13. SALE, Quality Control of Analytical Chemical Measurements

    International Nuclear Information System (INIS)

    Bush, W.J.; Gentillon, C.D.

    1985-01-01

    1 - Description of problem or function: The Safeguards Analytical Laboratory Evaluation (SALE) program is a statistical analysis program written to analyze the data received from laboratories participating in the SALE quality control and evaluation program. The system is aimed at identifying and reducing analytical chemical measurement errors. Samples of well-characterized materials are distributed to laboratory participants at periodic intervals for determination of uranium or plutonium concentration and isotopic distributions. The results of these determinations are statistically evaluated and participants are informed of the accuracy and precision of their results. 2 - Method of solution: Various statistical techniques produce the SALE output. Assuming an unbalanced nested design, an analysis of variance is performed, resulting in a test of significance for time and analyst effects. A trend test is performed. Both within- laboratory and between-laboratory standard deviations are calculated. 3 - Restrictions on the complexity of the problem: Up to 1500 pieces of data for each nuclear material sampled by a maximum of 75 laboratories may be analyzed

  14. Quality control chart for crushed granite concrete

    Directory of Open Access Journals (Sweden)

    Ewa E. DESMOND

    2016-07-01

    Full Text Available A chart for assessing in-situ grade (strength of concrete, has been developed in this study. Four grades of concrete after the Nigerian General Specification for Roads and bridges (NGSRB-C20, C25, C30 and C35, is studied at different water-cement ratios for medium and high slump range. The concrete mixes are made from crushed granite rock as coarse aggregate with river sand as fine aggregate. Compression test on specimens are conducted at curing age of 1, 3, 7, 14, 21, 28 and 56 days. Results on concrete workability from slump values, and water-cement ratios revealed that specimens with lower water-cement ratio were less workable but had higher strength, compared to mixes with higher water cement ratio. A simple algorithm using nonlinear regression analysis performed on each experimental data set produced Strength-Age (S-A curves which were used to establish a quality control chart. The accuracy of these curves were evaluated by computing average absolute error (AAS, the error of estimate (EoE and the average absolute error of estimate (Abs EoE for each concrete mix. These were done based on the actual average experimental strengths to measure how close the predicted values are to the experimental data set. The absolute average error of estimate (Abs. EoE recorded was less than ±10% tolerance zone for concrete works.

  15. The IAEA's programme in analytical quality control

    International Nuclear Information System (INIS)

    Suschny, O.

    1980-10-01

    The purpose of the Analytical Quality Control Programme of the International Atomic Energy Agency is to help laboratories in the Agency's Member States to assess and, if necessary, to improve the reliability of their analytical work in areas related to nuclear technology and radioisotope utilisation. This is done by the organisation of analytical intercomparisons and by the provision of certified or uncertified reference materials. Recently intercomparisons have been organised of trace element analysis in a soil and a lake sediment sample which have led to the certification of two new reference materials, SOIL-5 and SL-1 (lake sediment). A technique has been developed to recognise and to remove outlying results. Criteria have been established to classify element-concentration values into the categories ''established with a high degree of confidence'', ''established with a reasonable degree of confidence'' and ''information value only''. Four radionuclide intercomparisons have recently been carried out: W-1/1 and W-2/1 of the determination of selected radionuclides in water and Air-1/1 and Air-2/1 of that of selected radionuclides on simulated air filters. Details of the preparation of materials for these intercomparisons, and of data treatment and some results are discussed in the paper

  16. The quality control theory of aging

    Directory of Open Access Journals (Sweden)

    Warren Ladiges

    2014-05-01

    Full Text Available The quality control (QC theory of aging is based on the concept that aging is the result of a reduction in QC of cellular systems designed to maintain lifelong homeostasis. Four QC systems associated with aging are 1 inadequate protein processing in a distressed endoplasmic reticulum (ER; 2 histone deacetylase (HDAC processing of genomic histones and gene silencing; 3 suppressed AMPK nutrient sensing with inefficient energy utilization and excessive fat accumulation; and 4 beta-adrenergic receptor (BAR signaling and environmental and emotional stress. Reprogramming these systems to maintain efficiency and prevent aging would be a rational strategy for increased lifespan and improved health. The QC theory can be tested with a pharmacological approach using three well-known and safe, FDA-approved drugs: 1 phenyl butyric acid, a chemical chaperone that enhances ER function and is also an HDAC inhibitor, 2 metformin, which activates AMPK and is used to treat type 2 diabetes, and 3 propranolol, a beta blocker which inhibits BAR signaling and is used to treat hypertension and anxiety. A critical aspect of the QC theory, then, is that aging is associated with multiple cellular systems that can be targeted with drug combinations more effectively than with single drugs. But more importantly, these drug combinations will effectively prevent, delay, or reverse chronic diseases of aging that impose such a tremendous health burden on our society.

  17. The quality control theory of aging.

    Science.gov (United States)

    Ladiges, Warren

    2014-01-01

    The quality control (QC) theory of aging is based on the concept that aging is the result of a reduction in QC of cellular systems designed to maintain lifelong homeostasis. Four QC systems associated with aging are 1) inadequate protein processing in a distressed endoplasmic reticulum (ER); 2) histone deacetylase (HDAC) processing of genomic histones and gene silencing; 3) suppressed AMPK nutrient sensing with inefficient energy utilization and excessive fat accumulation; and 4) beta-adrenergic receptor (BAR) signaling and environmental and emotional stress. Reprogramming these systems to maintain efficiency and prevent aging would be a rational strategy for increased lifespan and improved health. The QC theory can be tested with a pharmacological approach using three well-known and safe, FDA-approved drugs: 1) phenyl butyric acid, a chemical chaperone that enhances ER function and is also an HDAC inhibitor, 2) metformin, which activates AMPK and is used to treat type 2 diabetes, and 3) propranolol, a beta blocker which inhibits BAR signaling and is used to treat hypertension and anxiety. A critical aspect of the QC theory, then, is that aging is associated with multiple cellular systems that can be targeted with drug combinations more effectively than with single drugs. But more importantly, these drug combinations will effectively prevent, delay, or reverse chronic diseases of aging that impose such a tremendous health burden on our society.

  18. Quality control culture of diagnostic ultrasound parameters

    International Nuclear Information System (INIS)

    Andam, A.A.B; Addison, E.C.K.; Aggry-Smith, S.; Nani, E.K.

    2003-01-01

    A phantom, consisting of two phases, has been designed and constructed to mimic the human body. The phase one phantom was designed to mimic a a surface lesion in the human body and the phase two phantom designed to mimic a section of the whole body. Ultrasound scans of the phantom were acquired for various material in the phantom at six hospitals in Kumasi, Ghana. A linear array transducer with parallel beams having a convex probe and a 3.5 MHz ultrasound frequency were used to carry out the experiment. It was observed that the depth of penetration of ultrasound, which constitutes the maximum depth of visualization or sensitivity, is determined by the frequency of the transducer, the attenuation of the medium being imaged and the system settings. Uniformity and linearity of the machines investigated were found to be within clinically acceptable standards. Spatial resolution, comprising axial and lateral resolutions, was observed to be satisfactory for the machines tested. It was observed that lateral resolution improved with the narrowing of the beam width. The ultrasound scanners at the selected hospitals were found to be operating at the expected level of performance. This work highlights the importance of putting in place a locally based mechanism for quality control of diagnostic ultrasound machines (author)

  19. QUALITY CONTROL OF SOME TRADITIONAL MEAT PRODUCTS

    Directory of Open Access Journals (Sweden)

    S. DOBRINAS

    2014-03-01

    Full Text Available In this paper, we present the characterization of six traditional meat products: smoked file, smoked bacon, pork sausages, sausage prepared from swine’s entrails, pork pastrami, sheep sausages. Organoleptic tests (the aspect and shape, the aspect of freshly cut in the section, smell, taste and consistency, physico-chemical and microbiological determinations (NTG, Salmonella, Listeria monocytogenes and Escherichia coli were performed. These analyzes are a part of quality control that must be done in order to obtain a certificate from the Ministry of Agriculture for a traditional product. After identification of H2S and starch and according to fat oxidation degree it was concluded that analyzed samples didn’t contain counterfeiters and all parameters analyzed are within the maximum limits allowed by law. Considering all the procedures for manufacturing, characteristics of raw and auxiliary materials, organoleptic properties of final products analyzed in this study, it can be concluded that analyzed meat specialties meet the requirements of Ministry Order no. 690/28.09.2004 for the traditional products certification.

  20. Bacterial lipoproteins; biogenesis, sorting and quality control.

    Science.gov (United States)

    Narita, Shin-Ichiro; Tokuda, Hajime

    2017-11-01

    Bacterial lipoproteins are a subset of membrane proteins localized on either leaflet of the lipid bilayer. These proteins are anchored to membranes through their N-terminal lipid moiety attached to a conserved Cys. Since the protein moiety of most lipoproteins is hydrophilic, they are expected to play various roles in a hydrophilic environment outside the cytoplasmic membrane. Gram-negative bacteria such as Escherichia coli possess an outer membrane, to which most lipoproteins are sorted. The Lol pathway plays a central role in the sorting of lipoproteins to the outer membrane after lipoprotein precursors are processed to mature forms in the cytoplasmic membrane. Most lipoproteins are anchored to the inner leaflet of the outer membrane with their protein moiety in the periplasm. However, recent studies indicated that some lipoproteins further undergo topology change in the outer membrane, and play critical roles in the biogenesis and quality control of the outer membrane. This article is part of a Special Issue entitled: Bacterial Lipids edited by Russell E. Bishop. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Quality assurance and quality control of nuclear analytical techniques

    International Nuclear Information System (INIS)

    Cincu, Emanuelathor

    2001-01-01

    Test and analytical laboratories in East and Central European countries need to prove the reliability and credibility of their economic, environmental, medical and legal decisions and their capacity of issuing reliable, verifiable reports. These demands imposed by the European Union aimed at avoiding a possible barrier to trade for the developing countries. In June 1999, in order to help Member States to develop according to EU objectives and the overall situation of the European market, IAEA launched a new co-operation programme designed to help the nuclear analytical laboratories in nuclear institutions and universities of Member States by training in the use of some Nuclear Analytical Techniques (NAT) that include: alpha, beta and gamma-ray spectrometry, radiochemical and neutron activation analysis, total reflection X-ray fluorescence. The Regional IAEA Project, named 'Quality Assurance/Quality Control of Nuclear Analytical Techniques' (NAT) aims at implementing the QA principles via a system of defined consecutive steps leading to a level on which the QA system is self-sustainable for formal accreditation or certification and satisfies the EU technical performance criteria; the requirements are in accordance with the new ISO/IEC 17025 Standard/Dec.1999 'General requirements for the competence of testing and calibration laboratories' - First edition. The Horia Hulubei National Institute for Nuclear Physics and Engineering, IFIN-HH, was admitted for participation in the IAEA Project in June 1999 account taken of its experience in the QA and metrology fields and its performance in the fields of beta and gamma-ray spectrometry, and radiochemical and neutron activation analysis, employed in both basic research and applications for external clients. Two working groups of specialists with the QA and Standardization and Metrology Departments and six analytical groups with the departments of Nuclear Applied Physics, Life Physics and Ionising Radiation Metrology are

  2. Mitochondrial quality control pathways as determinants of metabolic health

    NARCIS (Netherlands)

    Held, Ntsiki M.; Houtkooper, Riekelt H.

    2015-01-01

    Mitochondrial function is key for maintaining cellular health, while mitochondrial failure is associated with various pathologies, including inherited metabolic disorders and age-related diseases. In order to maintain mitochondrial quality, several pathways of mitochondrial quality control have

  3. Concrete and steel construction quality control and assurance

    CERN Document Server

    El-Reedy, Mohamed A

    2014-01-01

    Starting with the receipt of materials and continuing all the way through to the final completion of the construction phase, Concrete and Steel Construction: Quality Control and Assurance examines all the quality control and assurance methods involving reinforced concrete and steel structures. This book explores the proper ways to achieve high-quality construction projects, and also provides a strong theoretical and practical background. It introduces information on quality techniques and quality management, and covers the principles of quality control. The book presents all of the quality control and assurance protocols and non-destructive test methods necessary for concrete and steel construction projects, including steel materials, welding and mixing, and testing. It covers welding terminology and procedures, and discusses welding standards and procedures during the fabrication process, as well as the welding codes. It also considers the total quality management system based on ISO 9001, and utilizes numer...

  4. Descriptive study of the quality control in mammography

    International Nuclear Information System (INIS)

    Gaona, E.; Perdigon C, G.M.; Casian C, G.A.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M.

    2005-01-01

    The goal of mammography is to provide contrast between a lesion that is possible residing within the breast and normal surrounding tissue. Quality control is essential for maintaining the contrast imaging performance of a mammography system and incorporate tests that are relevant in that they are predictive of future degradation of contrast imaging performance. These tests will also be done at frequency that is high enough to intercept most drifts in quality imaging or performance before they become diagnostically significant. The quality control study has as objective to describe the results of the assessment of quality imaging elements (film optical density, contrast (density difference), uniformity, resolution and noise) of 62 mammography departments without quality control program and comparison these results with a mammography reference department with a quality control program. When comparing the results they allow seeing the clinical utility of to have a quality control program to reduce the errors of mammography interpretation. (Author)

  5. Analytical approaches to quality assurance and quality control in rangeland monitoring data

    Science.gov (United States)

    Producing quality data to support land management decisions is the goal of every rangeland monitoring program. However, the results of quality assurance (QA) and quality control (QC) efforts to improve data quality are rarely reported. The purpose of QA and QC is to prevent and describe non-sampling...

  6. Title IV Quality Control Project, Stage II. Management Option II: Delivery System Quality Improvements.

    Science.gov (United States)

    Advanced Technology, Inc., Reston, VA.

    Stage Two of the Title IV Quality Control Project is an integrated study of quality in five related Federal financial aid programs for postsecondary students. Section 1 of the paper establishes a framework for defining quality improvements, in order to identify the types of changes that would tend to improve quality across all facets of the…

  7. 7 CFR 58.442 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control. Representative...

  8. Introduction to Quality Control in a Compounding Pharmacy.

    Science.gov (United States)

    Allen, Loyd V

    2016-01-01

    A quality-based program is vital in every compounding pharmacy to ensure that each preparation is compounded properly and is stable for its expected duration of use. This article discusses quality control, quality assurance, continuous quality improvement, and also describes the components of an in-house (in-pharmacy) quality program, as well as the role of outside laboratories. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  9. Implementing self sustained quality control procedures in a clinical laboratory.

    Science.gov (United States)

    Khatri, Roshan; K C, Sanjay; Shrestha, Prabodh; Sinha, J N

    2013-01-01

    Quality control is an essential component in every clinical laboratory which maintains the excellence of laboratory standards, supplementing to proper disease diagnosis, patient care and resulting in overall strengthening of health care system. Numerous quality control schemes are available, with combinations of procedures, most of which are tedious, time consuming and can be "too technical" whereas commercially available quality control materials can be expensive especially for laboratories in developing nations like Nepal. Here, we present a procedure performed at our centre with self prepared control serum and use of simple statistical tools for quality assurance. The pooled serum was prepared as per guidelines for preparation of stabilized liquid quality control serum from human sera. Internal Quality Assessment was performed on this sample, on a daily basis which included measurement of 12 routine biochemical parameters. The results were plotted on Levey-Jennings charts and analysed with quality control rules, for a period of one month. The mean levels of biochemical analytes in self prepared control serum were within normal physiological range. This serum was evaluated every day along with patients' samples. The results obtained were plotted on control charts and analysed using common quality control rules to identify possible systematic and random errors. Immediate mitigation measures were taken and the dispatch of erroneous reports was avoided. In this study we try to highlight on a simple internal quality control procedure which can be performed by laboratories, with minimum technology, expenditure, and expertise and improve reliability and validity of the test reports.

  10. The results of a quality-control programme in mammography

    International Nuclear Information System (INIS)

    Ramsdale, M.L.; Hiles, P.A.

    1989-01-01

    With the introduction of a breast screening programme in the UK, quality assurance in mammography is of paramount importance in assuring optimum imaging performance with low dose. Quality control checks are an essential part of the quality-assurance system. A quality-control programme at a breast screening clinic is described. Daily checks include film sensitometry for X-ray processor control and radiography of a lucite phantom to monitor the consistency of the X-ray machine automatic exposure control. Weekly checks include additional measurements on the performance of the automatic exposure control for different breast thickness and an overall assessment of image quality using a prototype mammography test phantom. The test phantom measures low-contrast sensitivity, high-contrast resolution and small-detail visibility. The results of the quality-control programme are presented with particular attention paid to tolerances and limiting values. (author)

  11. Quality control with R an ISO standards approach

    CERN Document Server

    Cano, Emilio L; Prieto Corcoba, Mariano

    2015-01-01

    Presenting a practitioner's guide to capabilities and best practices of quality control systems using the R programming language, this volume emphasizes accessibility and ease-of-use through detailed explanations of R code as well as standard statistical methodologies. In the interest of reaching the widest possible audience of quality-control professionals and statisticians, examples throughout are structured to simplify complex equations and data structures, and to demonstrate their applications to quality control processes, such as ISO standards. The volume balances its treatment of key aspects of quality control, statistics, and programming in R, making the text accessible to beginners and expert quality control professionals alike. Several appendices serve as useful references for ISO standards and common tasks performed while applying quality control with R.

  12. 42 CFR 84.256 - Quality control requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  13. Internal quality control of RIA with Tonks error calculation method

    International Nuclear Information System (INIS)

    Chen Xiaodong

    1996-01-01

    According to the methodology feature of RIA, an internal quality control chart with Tonks error calculation method which is suitable for RIA is designed. The quality control chart defines the value of the allowance error with normal reference range. The method has the simplicity of its performance and directly perceived through the senses. Taking the example of determining T 3 and T 4 , the calculation of allowance error, drawing of quality control chart and the analysis of result are introduced

  14. Proteomics Quality Control: Quality Control Software for MaxQuant Results.

    Science.gov (United States)

    Bielow, Chris; Mastrobuoni, Guido; Kempa, Stefan

    2016-03-04

    Mass spectrometry-based proteomics coupled to liquid chromatography has matured into an automatized, high-throughput technology, producing data on the scale of multiple gigabytes per instrument per day. Consequently, an automated quality control (QC) and quality analysis (QA) capable of detecting measurement bias, verifying consistency, and avoiding propagation of error is paramount for instrument operators and scientists in charge of downstream analysis. We have developed an R-based QC pipeline called Proteomics Quality Control (PTXQC) for bottom-up LC-MS data generated by the MaxQuant software pipeline. PTXQC creates a QC report containing a comprehensive and powerful set of QC metrics, augmented with automated scoring functions. The automated scores are collated to create an overview heatmap at the beginning of the report, giving valuable guidance also to nonspecialists. Our software supports a wide range of experimental designs, including stable isotope labeling by amino acids in cell culture (SILAC), tandem mass tags (TMT), and label-free data. Furthermore, we introduce new metrics to score MaxQuant's Match-between-runs (MBR) functionality by which peptide identifications can be transferred across Raw files based on accurate retention time and m/z. Last but not least, PTXQC is easy to install and use and represents the first QC software capable of processing MaxQuant result tables. PTXQC is freely available at https://github.com/cbielow/PTXQC .

  15. A Total Quality-Control Plan with Right-Sized Statistical Quality-Control.

    Science.gov (United States)

    Westgard, James O

    2017-03-01

    A new Clinical Laboratory Improvement Amendments option for risk-based quality-control (QC) plans became effective in January, 2016. Called an Individualized QC Plan, this option requires the laboratory to perform a risk assessment, develop a QC plan, and implement a QC program to monitor ongoing performance of the QC plan. Difficulties in performing a risk assessment may limit validity of an Individualized QC Plan. A better alternative is to develop a Total QC Plan including a right-sized statistical QC procedure to detect medically important errors. Westgard Sigma Rules provides a simple way to select the right control rules and the right number of control measurements. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. The results of a quality-control programme in mammography

    International Nuclear Information System (INIS)

    Ramsdale, M.L.; Hiles, P.A.

    1989-01-01

    A quality-control programme at a breast screening clinic is described. Daily checks include film sensitometry for X-ray processor control and radiography of a lucite phantom to monitor the consistency of the X-ray machine automatic exposure control. Weekly checks include additional measurements on the performance of the automatic exposure control for different breast thickness and an overall assessment of image quality using a prototype mammography test phantom. The test phantom measures low-contrast sensitivity, high-control resolution and small-detail visibility. The results of the quality-control programme are presented with particular attention paid to tolerances and limiting values. (author)

  17. Impact of emission control on regional air quality in the Pearl Delta River region, southern China

    Science.gov (United States)

    Wang, N.; Xuejiao, D.

    2017-12-01

    The Pearl River Delta (PRD) in China has been suffering from air quality issues and the government has implemented a series of strategies in controlling emissions. In an attempt to provide scientific support for improving air quality, the paper investigates the concerning past-to-present air quality data and assesses air quality resulting from emission control. Statistical data revealed that energy consumption doubled from 2004 to 20014 and vehicle usage increased significantly from 2006 to 2014. Due to the effect of control efforts, primary emission of SO2, NOx and PM2.5 decreased resulting in ambient concentrations of SO2, NO2 and PM10 decreased by 66%, 20% and 24%, respectively. However, O3 increased 19% because of the increase of VOC emission. A chemical transport model, the Community Multi-scale Air Quality, was employed to evaluate the responses of nitrate, ammonium, SOA, PM2.5 and O3 to changes in NOx, VOC and NH3 emissions. Three scenarios, a baseline scenario, a CAP scenario (control strength followed as past tendency), and a REF scenario (strict control referred to latest policy and plans), were conducted to investigate the responses and mechanisms. NOx controlling scenarios showed that NOx, nitrate and PM2.5 reduced by 1.8%, 0.7% and 0.2% under CAP and reduced by 7.2%, 1.8% and 0.3% under REF, respectively. The results indicated that reducing NOx emission caused the increase of atmospheric oxidizability, which might result in a compensation of PM2.5 due to the increase of nitrate or sulfate. NH3 controlling scenarios showed that nitrate was sensitive to NH3 emission in PRD, with nitrate decreased by 0 - 10.6% and 0 - 48% under CAP and REF, respectively. Since controlling NH3 emissions not only reduced ammonium but also significantly reduced nitrate, the implement of NH3 controlling strategy was highly suggested. The VOC scenarios revealed that though SOA was not the major component of PM2.5, controlling VOC emission might take effect in southwestern PRD

  18. General Quality Control (QC) Guidelines for SAM Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  19. Intra- and Intercellular Quality Control Mechanisms of Mitochondria

    Directory of Open Access Journals (Sweden)

    Yoshimitsu Kiriyama

    2017-12-01

    Full Text Available Mitochondria function to generate ATP and also play important roles in cellular homeostasis, signaling, apoptosis, autophagy, and metabolism. The loss of mitochondrial function results in cell death and various types of diseases. Therefore, quality control of mitochondria via intra- and intercellular pathways is crucial. Intracellular quality control consists of biogenesis, fusion and fission, and degradation of mitochondria in the cell, whereas intercellular quality control involves tunneling nanotubes and extracellular vesicles. In this review, we outline the current knowledge on the intra- and intercellular quality control mechanisms of mitochondria.

  20. Quality control system response to stochastic growth of amyloid fibrils

    DEFF Research Database (Denmark)

    Pigolotti, S.; Lizana, L.; Sneppen, K.

    2013-01-01

    We introduce a stochastic model describing aggregation of misfolded proteins and degradation by the protein quality control system in a single cell. Aggregate growth is contrasted by the cell quality control system, that attacks them at different stages of the growth process, with an efficiency...... that decreases with their size. Model parameters are estimated from experimental data. Two qualitatively different behaviors emerge: a homeostatic state, where the quality control system is stable and aggregates of large sizes are not formed, and an oscillatory state, where the quality control system...

  1. The study on quality control of bedside CR examination

    International Nuclear Information System (INIS)

    Yang Xufeng; Luo Xiaomei; Xu Qiaolan; Wu Tengfang; Wen Xingwei

    2007-01-01

    Objective: To study the quality controll of bedside CR examination and improves the imaging quality. Methods: X-ray examination with CR system were performed on 3,300 patients. All CR cassettes were encoded. The imaging plate and cassettes were cleaned regularly. Results: With and without quality control, the percentage of first-rate film was 58.2% and 51%, the second-rate film was 40% and 45.5%, the third-rate film was 1.3% and 2%, respectively. Corxespondingly, the ratio of re-examination decreased from 1.5% to 0.5% after quality control, and imaging quality was stable. Conclusion: The quality control of bedside CR examination can improve the image quality as well as lighten the labor of radiographers. (authors)

  2. Convergence theorems for strictly hemi-contractive maps

    International Nuclear Information System (INIS)

    Chidume, C.E.; Osilike, M.O.

    1992-04-01

    It is proved that each of two well-known fixed point iteration methods (the Mann and the Ishikawa iteration methods) converges strongly to the fixed point of strictly hemi-contractive map in real Banach spaces with property (U, λ, m+1,m), λ is an element of R, m is an element of IN. The class of strictly hemi-contractive maps includes all strictly pseudo-contractive maps with nonempty fixed point sets; and Banach spaces with property (U, λ, m+1, m), λ is an element of R, m is an element of IN include the L p (or l p ) spaces, p≥2. Our theorems generalize important known results. (author). 22 refs

  3. Controle de qualidade e artefatos em mamografia Quality control and artifacts in mammography

    Directory of Open Access Journals (Sweden)

    Flávio Augusto Ataliba Caldas

    2005-08-01

    Full Text Available A mamografia, na atualidade, é o método mais efetivo de diagnóstico precoce do câncer de mama. Um exame com alto padrão de qualidade pode visualizar, em 85% a 90% dos casos, um tumor com mais de dois anos de antecedência de ocorrer acometimento ganglionar, em mulheres com mais de 50 anos de idade. A diferença radiográfica entre o tecido normal e o doente é extremamente tênue, logo, a alta qualidade do exame é indispensável para alcançar resolução de alto contraste que permita essa diferenciação. Para alcançar alto padrão é imperativo que o exame mamográfico siga protocolos rígidos e pré-estabelecidos. Os artefatos são defeitos no processamento do filme que comprometem o resultado final da imagem, podendo resultar em informações perdidas ou mascaradas. Há numerosos tipos de artefatos derivados de diversas fontes na aquisição da imagem, como o processador, o desempenho do técnico de radiologia, o mamógrafo ou o paciente, todos resultando na degradação da imagem obtida. O presente artigo tem o objetivo de revisar métodos eficazes no controle de qualidade do exame mamográfico e analisar os artefatos mais importantes na prática diária, com ilustrações e dicas de como evitá-los.Currently, mammography is the most effective method for an early diagnosis of breast cancer. In 85% to 90% of the cases, a high quality mammography allows the visualization of a tumor more than two years before the occurrence of lymph nodes involvement in women over 50 years of age. The radiological appearance of a normal and a sick tissue is very similar, therefore, a high quality of the scan is essential to obtain high contrast resolution to allow distinguishing them. Strict and preestablished protocols must be followed during mammography in order to reach high quality standards. Artifacts are defects occurred during film processing that interfere in the quality of the final image and can result in loss or masked information. Several

  4. Secondary Control for Voltage Quality Enhancement in Microgrids

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Jalilian, Alireza; Vasquez, Juan Carlos

    2012-01-01

    In this paper, a hierarchical control scheme is proposed for enhancement of sensitive load bus (SLB) voltage quality in microgrids. The control structure consists of primary and secondary levels. The primary control level comprises distributed generators (DGs) local controllers. Each of these con......In this paper, a hierarchical control scheme is proposed for enhancement of sensitive load bus (SLB) voltage quality in microgrids. The control structure consists of primary and secondary levels. The primary control level comprises distributed generators (DGs) local controllers. Each...

  5. Teaching Quality Control with Chocolate Chip Cookies

    Science.gov (United States)

    Baker, Ardith

    2014-01-01

    Chocolate chip cookies are used to illustrate the importance and effectiveness of control charts in Statistical Process Control. By counting the number of chocolate chips, creating the spreadsheet, calculating the control limits and graphing the control charts, the student becomes actively engaged in the learning process. In addition, examining…

  6. Quality-control design for surface-water sampling in the National Water-Quality Network

    Science.gov (United States)

    Riskin, Melissa L.; Reutter, David C.; Martin, Jeffrey D.; Mueller, David K.

    2018-04-10

    The data-quality objectives for samples collected at surface-water sites in the National Water-Quality Network include estimating the extent to which contamination, matrix effects, and measurement variability affect interpretation of environmental conditions. Quality-control samples provide insight into how well the samples collected at surface-water sites represent the true environmental conditions. Quality-control samples used in this program include field blanks, replicates, and field matrix spikes. This report describes the design for collection of these quality-control samples and the data management needed to properly identify these samples in the U.S. Geological Survey’s national database.

  7. Control of Bank Consolidated Financial Statements Quality

    OpenAIRE

    Margarita S. Ambarchyan

    2013-01-01

    The author presents the multiple linear regression model of bank consolidated financial statements quality. The article considers six characteristics that can be used to estimate the level of bank consolidated financial statements quality. The multiple linear regression model was developed, using the results of point-based system of consolidated financial statements of thirty European bank and financial groups on the basis of the developed characteristics. The author offers to use the charact...

  8. Quality control of recycled asphaltic concrete : final report.

    Science.gov (United States)

    1982-07-01

    This study examined the variations found in recycled asphaltic concrete mix based upon plant quality control data and verification testing. The data was collected from four recycled hot-mix projects constructed in 1981. All plant control and acceptan...

  9. Quality control of sputum microscopic examinations for acid fast ...

    African Journals Online (AJOL)

    Preferred Customer

    in the Southern Region of Ethiopia, and quality control has been initiated as part of this effort. Objective: To evaluate the ... National Tuberculosis and Leprosy Control Programme. (TLCP) manual for ..... laboratories in Mexico. Int J Tuberc Lung ...

  10. METHODS OF AUTOMATIC QUALITY CONTROL OF AGGLUTINANTSANDS IN FOUNDRY

    Directory of Open Access Journals (Sweden)

    D. M. Kukuj

    2004-01-01

    Full Text Available The article is dedicated to comparative analysis of the well-known methods of automatic quality control of agglutinant sands in process of their preparation and to the problems of automation control of the mix preparation processes.

  11. Managing Air Quality - Multi-Pollutant Planning and Control

    Science.gov (United States)

    Describes how planning controls for multiple pollutants at the same time can save money and time and achieve significant benefits, and how control strategies can address both climate change and air quality.

  12. AUTOMATION OF THE SYSTEM OF INTERNAL LABORATORY QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    V. Z. Stetsyuk

    2015-05-01

    Full Text Available Quality control system base d on the principles of standardi zation of all phases of laboratory testing and analysis of internal laboratory quality control and external quality assessment. For the detection accuracy of the results of laboratory tests, carried out internally between the laboratory and laboratory quality control. Under internal laboratory quality control we understand measurement results of each analysis in each anal ytical series rendered directly in the lab every day. The purpose of internal laboratory control - identifying and eliminating unacceptable deviations from standard perfor mance test in the laboratory, i.e. identifying and eliminating harmful analytical errors. The solutions to these problems by implementing automated systems - software that allows you to optimize analytical laboratory research stage of the procedure by automatically creating process control charts was shown.

  13. Food and Nutrition Services Quality Control Management Program.

    Science.gov (United States)

    Wimsatt-Fraim, Teresa S.

    A program was conducted to improve the quality of food service through the training of 44 food and nutrition service employees in a 200-bed hospital. A 12-week quality control program was implemented to address four key areas: food temperatures, food accuracy, food quality, and dietary personnel. Learning strategies, emphasizing critical thinking…

  14. The process of managerial control in quality improvement initiatives.

    Science.gov (United States)

    Slovensky, D J; Fottler, M D

    1994-11-01

    The fundamental intent of strategic management is to position an organization with in its market to exploit organizational competencies and strengths to gain competitive advantage. Competitive advantage may be achieved through such strategies as low cost, high quality, or unique services or products. For health care organizations accredited by the Joint Commission on Accreditation of Healthcare Organizations, continually improving both processes and outcomes of organizational performance--quality improvement--in all operational areas of the organization is a mandated strategy. Defining and measuring quality and controlling the quality improvement strategy remain problematic. The article discusses the nature and processes of managerial control, some potential measures of quality, and related information needs.

  15. Quality control of commercial bovine lactoferrin.

    Science.gov (United States)

    Wakabayashi, Hiroyuki; Yamauchi, Koji; Abe, Fumiaki

    2018-06-01

    Herein we review commercial bovine lactoferrin quality issues by describing an example of industrial production, the current status of global quality standardization, and quality-activity concerns for further discussion. Morinaga Milk Industry has been industrially producing bovine lactoferrin in Milei GmbH, Germany, since 1989. We delineate its production and quality as an example of safe and high-quality manufacturing. Currently, global standardization in the quality of bovine lactoferrin is progressing through Novel Food and GRAS in the EU and USA, respectively. Novel Food was applied or notified to seven lactoferrin manufacturers and GRAS was notified to three manufacturers, two of which are for infant use and one is for adult use, by the end of 2017. The specifications of these regulations are relatively high, including more than 95% lactoferrin purity in protein, which means that such companies can supply relatively high-grade lactoferrin. There appear to be several concerns regarding lactoferrin quality affecting activities, including contamination of lipopolysaccharide (LPS) and angiogenin, purity, and degradation of lactoferrin sample. Although LPS is immunologically toxic when invading the body, it is distributed normally in foods and the gut. However, an industrial lactoferrin sample may contain LPS at a maximum LPS/lactoferrin molecule ratio = 1/1724, which means 99.9% of the lactoferrin molecule is LPS-free. It is difficult to speculate that LPS contained in a lactoferrin sample affects its activities. Finally in order to achieve good and reproducible results, we make proposals to researchers a use of high-grade lactoferrin, careful storage, and indication the manufacturers' names and specifications in the paper.

  16. Quality assurance and quality control for Hydro-Quebec's ambient air monitoring networks

    International Nuclear Information System (INIS)

    Lambert, M.; Varfalvy, L.

    1993-01-01

    Hydro Quebec has three ambient air monitoring networks to determine the contribution of some of its thermal plants to ambient air quality. They are located in Becancour (gas turbines), Iles-de-la-Madeleine (diesel), and Tracy (conventional oil-fired). To ensure good quality results and consistency between networks, a quality assurance/quality control program was set up. A description is presented of the ambient air quality monitoring network and the quality assurance/quality control program. A guide has been created for use by the network operators, discussing objectives of the individual network, a complete description of each network, field operation for each model of instrument in use, treatment of data for each data logger in use, global considerations regarding quality assurance and control, and reports. A brief overview is presented of the guide's purpose and contents, focusing on the field operation section and the sulfur dioxide and nitrogen oxide monitors. 6 figs., 1 tab

  17. Quality control of mammography departments in Slovakia

    International Nuclear Information System (INIS)

    Horvathova, M.; Nikodemova, D.

    2007-01-01

    Complete test of publication follows. Considering the fact that mammary gland is the most sensitive organ to ionizing radiation, the Commission of the Ministry of Health of SR for QA in radiology organized a pilot two-run country wide audit conducted in 42 mammography departments that have met the beforehand criteria. During the audit the methods for establishing the individual parameters in technical and clinical part of quality assurance in mammography were elaborated and implemented. Technical and clinical parameters of the imaging process that mostly affect the quality of diagnostic information were followed up. These parameters included: the object thickness compensation, optical density deviation, evaluation of the film quality by means of special phantom, etc. Important measurement of ESDs at participating departments enabled to compare the radiation load of mammography patients in Slovakia with reference values in European guidelines. The uniform standard method for QA at mammography departments was elaborated and published as the regulation of the Ministry of Health for performance of preventive mammography examinations in SR. The presented results show the improved quality of mammography examinations due to regular check-ups of technical and clinical parameters and fulfilment of the required values in all parameters. The audit results are the basis for continuous quality assessment of mammography departments as a main prerequisite for conducting preventive examinations and for health insurance purposes.

  18. [On-site quality control of acupuncture randomized controlled trial: design of content and checklist of quality control based on PICOST].

    Science.gov (United States)

    Li, Hong-Jiao; He, Li-Yun; Liu, Zhi-Shun; Sun, Ya-Nan; Yan, Shi-Yan; Liu, Jia; Zhao, Ye; Liu, Bao-Yan

    2014-02-01

    To effectively guarantee quality of randomized controlld trial (RCT) of acupuncture and develop reasonable content and checklist of on-site quality control, influencing factors on quality of acupuncture RCT are analyzed and scientificity of quality control content and feasibility of on-site manipulation are put into overall consideration. Based on content and checklist of on-site quality control in National 11th Five-Year Plan Project Optimization of Comprehensive Treatment Plan for TCM in Prevention and Treatment of Serious Disease and Clinical Assessment on Generic Technology and Quality Control Research, it is proposed that on-site quality control of acupuncture RCT should be conducted with PICOST (patient, intervention, comparison, out come, site and time) as core, especially on quality control of interveners' skills and outcome assessment of blinding, and checklist of on-site quality control is developed to provide references for undertaking groups of the project.

  19. Quality control protocols for radiodiagnosis agents and radiopharmaceuticals

    International Nuclear Information System (INIS)

    Robles, A.; Condor, M.; Caballero, J.; Morote, M.; Garcia, C.; Benites, M.

    1997-01-01

    Based on the compilation of pharmacopoeia methods, literature, manuals and other information developed in our laboratory, protocols have been prepared to carry out quality controls for radiodiagnosis agents (RDA), better known as kits and RDA labelled with Tc99m. Quality control protocols cover physicochemical and biological controls. Physicochemical controls described for RDA include physical characteristics, particle size and number, pH, chemical identification, humidity, tin II; whereas biological controls include sterility, acute toxicity and bacterial endotoxin determination (LAL). Physicochemical controls described for radiopharmaceuticals labelled with Tc99m are pH and radiochemical purity; while biological distribution is described as a biological control

  20. Analytic properties of form factors in strictly confining models

    International Nuclear Information System (INIS)

    Csikor, F.

    1979-12-01

    An argument is presented showing that strict confinement implies the possible existence of an (unwanted) branch point at q 2 =0 in the form factors. In case of a bag extended to infinity in the relative time, the branch point is certainly there (provided that the form factor is non zero at q 2 =0). (author)

  1. Dominance on Strict Triangular Norms and Mulholland Inequality

    Czech Academy of Sciences Publication Activity Database

    Petrík, Milan

    2018-01-01

    Roč. 335, 15 March (2018), s. 3-17 ISSN 0165-0114 R&D Projects: GA ČR GJ15-07724Y Institutional support: RVO:67985807 Keywords : dominance relation * Mulholland inequality * strict triangular norm * transitivity Subject RIV: BA - General Mathematics Impact factor: 2.718, year: 2016

  2. Effects of strict prolonged bed rest on cardiorespiratory fitness

    DEFF Research Database (Denmark)

    Ried-Larsen, Mathias; Aarts, Hugo M; Joyner, Michael J

    2017-01-01

    The aim of this systematic review and meta-analysis [International Prospective Register of Systematic Reviews (PROSPERO) CRD42017055619] was to assess the effects of strict prolonged bed rest (without countermeasures) on maximal oxygen uptake (V̇o2max) and to explore sources of variation therein....

  3. Intergrated approach to quality control procedures of radioisotopes and radiopharmaceuticals

    International Nuclear Information System (INIS)

    Rohani Mohamad

    1986-01-01

    Various aspects of the quality control procedures for radioisotopes and radiopharmaceuticals have been discussed. The paper high lighted those procedures that are important in ensuring the efficacy of the product. It also gives a general idea of the various procedures that are actually carried out by the Quality Control Section. (A.J.)

  4. Electronic quality control on dental x-rays equipment

    International Nuclear Information System (INIS)

    Pomares C, Martin

    1996-09-01

    A brief description of dental x-ray equipment is done. The non-invasive quality control is treated as than the responsibilities from the dentists to the patient and the equipment. A propose for quality control for dental x-ray equipment, film and developer is include

  5. Status and future trends of Analytical Quality Control Services

    International Nuclear Information System (INIS)

    LaBrecque, J.J.; Schelenz, R.; Hardy, E.P.

    1987-07-01

    This report reviews the present Analytical Quality Control Services (AQCS) programme components in the light of the needs of IAEA Member States for analytical reference materials and intercomparisons, provides guidelines for the direction which the programme should take in the future and identifies the type of Analytical Quality Control Services most urgently required by the Member States

  6. Safety of timber : An analysis of quality control options

    NARCIS (Netherlands)

    Kovryga, A.; Stapel, P.; Van de Kuilen, J.W.G.

    2014-01-01

    The quality assurance of timber properties is important for the safety of timber structures. In the current study, the quality control options of timber are analysed under the prism of the different growth regions. Therefore, these options - machine and output control - are simulated in accordance

  7. Chemical and physical quality control of the HIPPURAN-131I

    International Nuclear Information System (INIS)

    Morin Zorilla, J.; Olive, E.; Isaac, M.; Cruz, J.

    1989-01-01

    Some physico-chemical methods for analytical control of Hippuran- 131 I are compared. The most convenient to applicate in hospitals and in more specialized quality control laboratories are recommended. The quality of Hippuran- 131 I produced by ISOTOP (USSR) is also evaluated. The product met the requirement of the International Pharmacopeia

  8. Internal quality control in serological tests for syphilis.

    OpenAIRE

    Wasley, G D

    1985-01-01

    The importance of syphilis serological tests demands that laboratory reports are reliable. Internal quality control applied to the organisation of a syphilis serology service improves laboratory bench performance and reporting. Described here are internal quality control procedures of a department that serves a genitourinary medicine clinic and conducts 70 000 tests a year to investigate for syphilis.

  9. Application of improved quality control technology to pressure vessels

    International Nuclear Information System (INIS)

    Kriedt, F.

    1985-01-01

    Within the last decade, ASME Boiler and Pressure Vessel Code Section VIII-1 instituted requirements for a formal written quality control system. The results, good and bad, of this requirement are discussed. The effects are far reaching from a national economic standpoint. Quality control technology has improved. These improvements are discussed and compared to existing requirements of the CODE. Recommended improvements are suggested

  10. Quality control of geological voxel models using experts' gaze

    NARCIS (Netherlands)

    Maanen, P.P. van; Busschers, F.S.; Brouwer, A.M.; Meulen, M.J. van der; Erp, J.B.F. van

    2015-01-01

    Due to an expected increase in geological voxel model data-flow and user demands, the development of improved quality control for such models is crucial. This study explores the potential of a new type of quality control that improves the detection of errors by just using gaze behavior of 12

  11. Quality Control of Geological Voxel Models using Experts' Gaze

    NARCIS (Netherlands)

    van Maanen, Peter-Paul; Busschers, Freek S.; Brouwer, Anne-Marie; van der Meulendijk, Michiel J.; van Erp, Johannes Bernardus Fransiscus

    Due to an expected increase in geological voxel model data-flow and user demands, the development of improved quality control for such models is crucial. This study explores the potential of a new type of quality control that improves the detection of errors by just using gaze behavior of 12

  12. Quality control of nuclear fuels - technical and economic aspects

    International Nuclear Information System (INIS)

    Strasser, A.A.

    1982-01-01

    The qualification and resolution of questions relating to the cost benefit of quality control are based on the interaction of a broad range of technologies and economics. This paper discusses examples of current areas of interest in quality control, and their relationship to the fuel cycle costs. (orig.)

  13. Design an Indoor Air Quality Controller Based on LPC2478

    Directory of Open Access Journals (Sweden)

    Shi Shuheng

    2014-07-01

    Full Text Available Indoor air quality is very important to our lives, because we spend most of our time indoor. In order to improve the air quality of indoor, this paper designs an indoor environment quality monitoring and controlling system based on ARM microcontroller LPC2478. It will do a real-time monitoring work for detecting the indoor environmental factors and comprehensively evaluate its air quality level. While the indoor air quality status is "poor", this intelligent system will automatically start the heat exchange ventilator for indoor environmental quality improvement. The results compared to traditional natural ventilation method show the better performance of proposed system.

  14. Dose calibrator user and quality control guide

    International Nuclear Information System (INIS)

    Blanchis, Philippe; Amiot, Marie-Noelle; Moune, Muriel; Bellanger, Anne-Christine; Chauvenet, Bruno; Verdeau, Eric; Gardin, Isabelle; Martineau, Antoine; Ricard, Marcel; Caselles, Olivier; Guilhem, Marie-Therese; Hapdey, Sebastien; Lisbona, Albert; Bonnot-Lours, Sophie; Dumont, Agnes; Lemercier, Valerie; Rizzo-Padoin, Nathalie

    2006-06-01

    This document is a practical guide for the use and control of dose calibrators which are instruments used for radioactivity measurements. After a recall of the calibrator operation principle, the authors describe all the operations performed on this apparatus all along its lifetime: controls to be performed for device acceptance, aspects to be addressed during installation, controls to be performed before any use, daily controls, more detailed controls, and operations to be performed for maintenance, in case of dysfunctions or for re-calibration

  15. Quality control of thermoluminesce personal dose monitoring

    International Nuclear Information System (INIS)

    Shang Aiguo; He Wenchang; Zhao Fengtao

    2006-01-01

    In order to evaluate the influence factor to thermoluminesce personal dose monitoring result, the every question that can appear based on the fact was analyzed. The results show that the detector, annealing, measuring process can influence the monitoring result. It gives some measures to enhance monitoring quality. (authors)

  16. Quality Control Specialist | Center for Cancer Research

    Science.gov (United States)

    Within the Leidos Biomedical Research Inc.’s Clinical Research Directorate, the Clinical Monitoring Research Program (CMRP) provides high-quality comprehensive and strategic operational support to the high-profile domestic and international clinical research initiatives of the National Cancer Institute (NCI), National Institute of Allergy and Infectious Diseases (NIAID),

  17. Strict follow-up programme including CT and (18) F-FDG-PET after curative surgery for colorectal cancer

    DEFF Research Database (Denmark)

    Sørensen, N F; Jensen, A B; Wille-Jørgensen, P

    2010-01-01

    Aim The risk of local recurrence following curative surgery for colorectal cancer (CRC) is up to 50%. A rigorous follow-up program may increase survival. Guidelines on suitable methods for scheduled follow up examinations are needed. This study evaluates a strict follow-up program including...... supported a strict follow-up program following curative surgery for colorectal cancer. FDG-PET combined with CT should be included in control programs....

  18. Quality assurance in education: The role of ICT and quality control ...

    African Journals Online (AJOL)

    Quality assurance in education is perceived in this paper to be a product of the impact of information and communication technologies as well as the statutory control measures especially in tertiary institutions in Nigeria. The paper reviews the concept of quality and quality assurance and their general application to ...

  19. How to set up and manage quality control and quality assurance

    NARCIS (Netherlands)

    Visschedijk, M.; Hendriks, R.; Nuyts, K.

    2005-01-01

    This document provides a general introduction to clarify the differences between quality control (QC) and quality assurance (QA). In addition it serves as a starting point for implementing a quality system approach within an organization. The paper offers practical guidance to the implementation of

  20. As we age: Does slippage of quality control in the immune system lead to collateral damage?

    Science.gov (United States)

    Müller, Ludmila; Pawelec, Graham

    2015-09-01

    The vertebrate adaptive immune system is remarkable for its possession of a very broad range of antigen receptors imbuing the system with exquisite specificity, in addition to the phagocytic and inflammatory cells of the innate system shared with invertebrates. This system requires strict control both at the level of the generation the cells carrying these receptors and at the level of their activation and effector function mediation in order to avoid autoimmunity and mitigate immune pathology. Thus, quality control checkpoints are built into the system at multiple nodes in the response, relying on clonal selection and regulatory networks to maximize pathogen-directed effects and minimize collateral tissue damage. However, these checkpoints are compromised with age, resulting in poorer immune control manifesting as tissue-damaging autoimmune and inflammatory phenomena which can cause widespread systemic disease, paradoxically compounding the problems associated with increased susceptibility to infectious disease and possibly cancer in the elderly. Better understanding the reasons for slippage of immune control will pave the way for developing rational strategies for interventions to maintain appropriate immunity while reducing immunopathology. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Proposed quality control protocol of a dual energy bone densitometer from Spanish protocol for quality control of radiology

    International Nuclear Information System (INIS)

    Saez, F.; Benito, M. A.; Collado, P.; Saez, M.

    2011-01-01

    In this paper we propose additional testing to complete the tests by the Spanish Protocol for Quality Control of Diagnostic Radiology, taking into account the particular characteristics of these units, and including these tests in the estimation of patient dose dose assessment area. There is also the possibility to independently verify the quality control tests that are done automatically.

  2. Quality Management of CERN Vacuum Controls

    CERN Document Server

    Antoniotti, F; Fortescue-Beck, E; Gama, J; Gomes, P; Le Roux, P; Pereira, H F; Pigny, G

    2014-01-01

    The vacuum controls Section (TE-VSC-ICM) is in charge of the monitoring, maintenance and consolidation of the control systems of all accelerators and detectors in CERN; this represents 6 000 instruments distributed along 128 km of vacuum chambers, often of heterogeneous architectures and of diverse

  3. PROCESS VARIABILITY REDUCTION THROUGH STATISTICAL PROCESS CONTROL FOR QUALITY IMPROVEMENT

    Directory of Open Access Journals (Sweden)

    B.P. Mahesh

    2010-09-01

    Full Text Available Quality has become one of the most important customer decision factors in the selection among the competing product and services. Consequently, understanding and improving quality is a key factor leading to business success, growth and an enhanced competitive position. Hence quality improvement program should be an integral part of the overall business strategy. According to TQM, the effective way to improve the Quality of the product or service is to improve the process used to build the product. Hence, TQM focuses on process, rather than results as the results are driven by the processes. Many techniques are available for quality improvement. Statistical Process Control (SPC is one such TQM technique which is widely accepted for analyzing quality problems and improving the performance of the production process. This article illustrates the step by step procedure adopted at a soap manufacturing company to improve the Quality by reducing process variability using Statistical Process Control.

  4. Water quality control device and water quality control method for reactor primary coolant system

    International Nuclear Information System (INIS)

    Wada, Yoichi; Ibe, Eishi; Watanabe, Atsushi.

    1995-01-01

    The present invention is suitable for preventing defects due to corrosion of structural materials in a primary coolant system of a BWR type reactor. Namely, a concentration measuring means measures the concentration of oxidative ingredients contained in a reactor water. A reducing electrode is disposed along a reactor water flow channel in the primary coolant system and reduces the oxidative ingredients. A reducing counter electrode is disposed along the reactor water flow channel in the primary coolant system, and electrically connected to the reducing electrode. The reactor structural materials are used as a reference electrode providing a reference potential to the reducing electrode and the reducing counter electrode. A potential control means controls the potential of the reducing electrode relative to the reference potential based on the signals from the concentration measuring means. A stable reference potential in a region where an effective oxygen concentration is stable can be obtained irrespective of the change of operation conditions by using the reactor structural materials disposed to a boiling region in the reactor core as a reference electrode. As a result, the water quality can be controlled at high accuracy. (I.S.)

  5. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    Energy Technology Data Exchange (ETDEWEB)

    Fishler, B

    2011-03-18

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  6. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    International Nuclear Information System (INIS)

    Fishler, B.

    2011-01-01

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  7. A phantom for quality control in mammography

    International Nuclear Information System (INIS)

    Gambaccini, M.; Rimondi, O.; Marziani, M.; Toti, A.

    1989-01-01

    A phantom for evaluating image quality in mammography has been designed and will be used in the Italian national programme ''Dose and Quality in Mammography''. The characteristics of the phantom are (a) about the same X-ray transmission as a 5 cm 50% fat and 50% water breast for energies between 15 and 50 keV and (b) optimum energies for imaging of the test objects (included in the phantom) in very close agreement with the optimum energies for imaging of calcifications and tumours in a 5 cm 50% fat and 50% water breast. An experimental comparison between the prototype and some commercial phantoms was carried out. Measurements are in progress to test the phantom's ability to evaluate the performances of mammographic systems quantitatively. (author)

  8. Justification and quality control in radiodiagnostics

    International Nuclear Information System (INIS)

    Dalen, A. van

    1989-01-01

    The role of the radiodiagnostician in justification of x-ray examination is discussed. Under the final responsibility of the radio-diagnostician the more common examinations are performed by laboratory assistants. A justification judgement before by the radio-diagnostician does not take place. In case of complicated examinations often previous consultation between radio-diagnostician and clinician is necessary. The fast development of new techniques like CT, echography and MRI has as result that the modern radio-diagnostician develops more and more into a imaging-specialist. In the consultation with the clinician he advises about the optimal diagnostics for a certain patient, taking optimally into account the risks of x-radiation. The justifying role of the radio-diagnostician depends further upon the relation with the requiring physician. In general the inter-collegial consultation is assumed to be sufficient within the hospitals, however the feedback to general practitioners seems to be improvable in some cases. With regard to quality assurance it is remarked that the quality of the examination may not be endangered by a too strong emphasis upon radiation reduction. Aspects like education level, protocol learning, dose limits, degressive tariffs, information-transfer, radiation passport, analysis between 'blue' ton, centralization of x-ray examination and quality of apparatus, are discussed. From the Government primarily a constraint setting policy is expected, in which rule-giving with respect to quality of education and apparatus is highly important. A stimulation of inter-collegial consulting may be expected, in particular in financial sense. A permission policy has to be managed, which ensures centralization of apparatus and centrally performance of x-ray examination as much as possible. Finally warning is given for the effects of excessive fear for radiation which causes refraining of medical necessary examination. The various risk have to be weighed up

  9. Some observations about quality control tests of Spect

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.

    1987-01-01

    Some observations about quality control tests done in the tomographic system of Heart Institute are described. Among the tests, the traditional test of quality control with scintillation camera and the specific test for tomography systems are induced. The traditional tests are essential, but not sufficient for evaluating the Spect equipment and the specific tests have been effectuated in controlled conditions. (C.G.C.) [pt

  10. Quality assurance/quality control training for plant operation and maintenance

    International Nuclear Information System (INIS)

    Bergbauer, A.K.

    1986-01-01

    One of the most important tasks during the period of plant operation is to ensure the effectiveness of the information links inside the utility and the nuclear industry. To make use of all information, experience and knowledge as well as to make sure that instructions are followed, it is necessary to provide rules, instructions and training for all people involved. QA/QC-training for plant operation and maintenance must deliver a consciousness of men in a way that e.g. instructions or procedures are followed strictly, the management is informed about deviations and mistakes, alterations are carried out with approval only, safety systems are kept integer all the time and interfaces are linked together properly. By means of examples about staff organization, control room and shift rules, work permit procedures and use of an information feedback system QA measures shall be demonstrated. (orig.)

  11. Effect of quality control implementation on image quality of radiographic films and irradiation doses to patients

    International Nuclear Information System (INIS)

    Cheng Yuxi; Zhou Qipu; Ge Lijuan; Hou Changsong; Qi Xuesong; Yue Baorong; Wang Zuoling; Wei Kedao

    1999-01-01

    Objective: To study the changes in the image quality of radiographic films and the irradiation doses to patients after quality control (QC) implementation. Methods: The entrance surface doses (ESD) to patients measured with TLD and the image quality of radiographic films were evaluated on the basis of CEC image quality criteria. Results: The ESD to patients were significantly reduced after QC implementation (P 0.05), but the post-QC image quality was significantly improved in chest PA, lumbar spine AP and pelvis AP(P0.01 or P<0.05). Conclusion: Significantly reduced irradiation dose with improved image quality can be obtained by QC implementation

  12. Management Model for efficient quality control in new buildings

    Directory of Open Access Journals (Sweden)

    C. E. Rodríguez-Jiménez

    2017-09-01

    Full Text Available The management of the quality control of each building process is usually set up in Spain from different levels of demand. This work tries to obtain a model of reference, to compare the quality control of the building process of a specific product (building, and to be able to evaluate its warranty level. In the quest of this purpose, we take credit of specialized sources and 153 real cases of Quality Control were carefully revised using a multi-judgment method. Applying different techniques to get a specific valuation (impartial of the input parameters through Delphi’s method (17 experts query, whose matrix treatment with the Fuzzy-QFD tool condenses numerical references through a weighted distribution of the selected functions and their corresponding conditioning factors. The model thus obtained (M153 is useful in order to have a quality control reference to meet the expectations of the quality.

  13. [Evaluation of the quality control system in blood transfusion service].

    Science.gov (United States)

    Jovanović, R

    2000-01-01

    Implementation of quality system improvement at the Blood Transfusion Institute Novi Sad, included adjustments in practice to the request of ISO 9001 standard. Quality improvement must be a permanent activity of the Institute. The audit is a management tool for monitoring the quality assurance system and is either a quality audit or a medical audit. A well planned, comprehensive quality audit covers each activity of the Blood Transfusion Institute. The procedures may be internal or external. Quality manager is responsible for annual internal quality audits. The purpose of internal audits is to check the efficiency of the quality system in terms of realization of quality policy, fulfullment of designed targets and implementation of quality system documents. An internal quality audit is performed in accordance with the procedure and audit findings are reported to the management in a form of internal quality report as a part of quality system review. The findings must be communicated to all persons responsible for the controlled area. Quality manager can initiate an internal quality audit whenever it is realized that problems about the quality system have occurred. Audits are conducted by the quality manager or an audit team. The accurate list of internal auditors is kept in the Institute archive. Medical audit carried out by a transfusion committee, evaluates the quality of blood transfusion for determining the degree of compliance with established local or national guidelines, in order to promote optimal transfusion practice. Audits are not only used for determining further quality management activities, but also make basis for creating and maintenance of excellent relations with product and service users. Considering all this, Blood Transfusion Institute exceeds the requirements of ISO 9000 standards series.

  14. Fuel element radiometry system for quality control

    International Nuclear Information System (INIS)

    Bhattacharya, Sadhana; Gaur, Swati; Sridhar, Padmini; Mukhopadhyay, P.K.; Vaidya, P.R.; Das, Sanjoy; Sinha, A.K.; Bhatt, Sameer

    2010-01-01

    An indigenous and fully automatic PC based radiometry system has been designed and developed. The system required a vibration free scanning with various automated sequential movements to scan the fuel pin of size 5.8 mm (OD) x 1055 mm (L) along its full length. A mechanical system with these requirements and precision controls has been designed. The system consists of a tightly coupled and collimated radiation source-detector unit and data acquisition and control system. It supports PLC based control electronics to control and monitor the movement of fuel element, nuclear data acquisition and analysis system and feedback system to the mechanical scanner to physically accept or reject the fuel pin based on the decision derived by the software algorithms. (author)

  15. Quality control of radioactive waste products

    International Nuclear Information System (INIS)

    Martens, B.R.; Warnecke, E.; Odoj, R.

    1986-01-01

    The variety of incoming untreated wastes, treatment methods, waste forms and containers requires a great variety of controlling methods and principles to be applied both during waste treatment and on the final product. The paper describes product control schemes and methods, sampling systems and transportable testing equipment for waste drums, and equipment for waste cementation using in-drum stirring and subsequent fixation of solid wastes in the flowable product. (DG) [de

  16. Dosimetry and quality control in radiodiagnosis

    International Nuclear Information System (INIS)

    Le Gouic, M.

    1983-07-01

    This work deals with physics of radiodiagnosis. In a first part a study of the characteristics of different kinds of radiological equipments and a quality assurance of some of them (standard radiography, coronarography and computed tomography) have been performed. The second part deals with patient irradiation. After a bibliographic study of radiodiagnosis dosimetry, two kinds of dosimetric measures have been made: ''in vitro'' measures, using a phantom, that had allowed to calibrate the equipment and to improve the individual irradiation card, and ''in vivo'' measures. For the first types of measures ionization chambers, have been used for the second thermoluminescent dosimeters [fr

  17. Internal control reporting and accounting quality : Insight "comply-or-explain" internal control regime

    OpenAIRE

    Cao Thi Thanh, Huyen; Cheung, Tina

    2010-01-01

    Nowadays, there exist two reporting regimes, rules-based and principle-based (comply-or-explain). In the rules-based environment, researchers have studied the relationship between internal control quality and accounting quality. Prior studies have suggested that reports on internal control are an effective way for investors to evaluate the quality of the firm‟s internal control. By having a sound system of internal control, it creates reliance upon the firm‟s financial reporting. Therefore, t...

  18. Internal quality control of PCR-based genotyping methods

    DEFF Research Database (Denmark)

    Bladbjerg, Else-Marie; Gram, Jørgen; Jespersen, Jørgen

    2002-01-01

    Internal quality control programmes for genetic analyses are needed. We have focused on quality control aspects of selected polymorphism analyses used in thrombosis research. DNA was isolated from EDTA-blood (n = 500) and analysed for 18 polymorphisms by polymerase chain reaction (PCR), i...... because of positive reagent blanks (controls (Control of data handling revealed 0.1% reading mistakes and 0.5% entry mistakes. Based on our experiences, we propose an internal quality control programme......, electrophoresis (analytical factors), result reading and entry into a database (post-analytical factors). Furthermore, we evaluated a procedure for result confirmation. Isolated DNA was of good quality (42 micrograms/ml blood, A260/A280 ratio > 1.75, negative DNAsis tests). Occasionally, results were reanalysed...

  19. [Coronary artery bypass surgery: methods of performance monitoring and quality control].

    Science.gov (United States)

    Albert, A; Sergeant, P; Ennker, J

    2009-10-01

    The strength of coronary bypass operations depends on the preservation of their benefits regarding freedom of symptoms, quality of life and survival, over decades. Significant variability of the results of an operative intervention according to the hospital or the operating surgeon is considered a weakness in the procedure. The external quality insurance tries to reach a transparent service providing market through hospital ranking comparability. Widely available information and competition will promote the improvement of the whole quality. The structured dialog acts as a control instrument for the BQS (Federal Quality Insurance). It is launched in case of deviations from the standard references or statistically significant differences between the results of the operations in any hospital and the average notational results. In comparison to the external control the hospital internal control has greater ability to reach a medically useful statement regarding the results of the treatment and to correct the mistakes in time. An online information portal based on a departmental databank (DataWarehouse, DataMart) is an attractive solution for the physician in order to get transparently and timely informed about the variability in the performance.The individual surgeon significantly influences the short- and long-term treatment results. Accordingly, selection, targeted training and performance measurements are necessary.Strict risk management and failure analysis of individual cases are included in the methods of internal quality control aiming to identify and correct the inadequacies in the system and the course of treatment. According to the international as well as our own experience, at least 30% of the mortalities after bypass operations are avoidable. A functioning quality control is especially important in minimally invasive interventions because they are often technically more demanding in comparison to the conventional procedures. In the field of OPCAB surgery

  20. Strong Convergence Theorems for a Pair of Strictly Pseudononspreading Mappings

    Directory of Open Access Journals (Sweden)

    Bin-Chao Deng

    2013-01-01

    Full Text Available Let H be a real Hilbert space. Let T1,T2:H→H be k1-, k2-strictly pseudononspreading mappings; let αn and βn be two real sequences in (0,1. For given x0∈H, the sequence xn is generated iteratively by xn+1=βnxn+1-βnTw1αnγfxn+I-μαnBTw2xn, ∀n∈N, where Twi=1−wiI+wiTi with i=1,2 and B:H→H is strongly monotone and Lipschitzian. Under some mild conditions on parameters αn and βn, we prove that the sequence xn converges strongly to the set FixT1∩FixT2 of fixed points of a pair of strictly pseudononspreading mappings T1 and T2.

  1. APPLICATION OF HIDDEN MARKOV CHAINS IN QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    Hanife DEMIRALP

    2013-01-01

    Full Text Available The ever growing technological innovations and sophistication in industrial processes require adequate checks on quality. Thus, there is an increasing demand for simple and efficient quality control methods. In this regard the control charts stand out in simplicity and efficiency. In this paper, we propose a method of controlling quality based on the theory of hidden Markov chains. Based on samples drawn at different times from the production process, the method obtains the state of the process probabilistically. The main advantage of the method is that it requires no assumption on the normality of the process output.

  2. Growth of a Strictly Anaerobic Bacterium on Furfural (2-Furaldehyde)

    OpenAIRE

    Brune, Gerhard; Schoberth, Siegfried M.; Sahm, Hermann

    1983-01-01

    A strictly anaerobic bacterium was isolated from a continuous fermentor culture which converted the organic constituents of sulfite evaporator condensate to methane and carbon dioxide. Furfural is one of the major components of this condensate. This furfural isolate could degrade furfural as the sole source of carbon and energy in a defined mineral-vitamin-sulfate medium. Acetic acid was the major fermentation product. This organism could also use ethanol, lactate, pyruvate, or fumarate and c...

  3. The Fixed-Point Theory of Strictly Causal Functions

    Science.gov (United States)

    2013-06-09

    functions were defined to be the functions that are strictly contracting with respect to the Cantor metric (also called the Baire distance) on signals...of Lecture Notes in Computer Science, pages 447–484. Springer Berlin / Heidelberg, 1992. [36] George Markowsky. Chain-complete posets and directed...Journal of Logic Programming, 42(2):59–70, 2000. [52] George M. Reed and A. William Roscoe. A timed model for communicating sequential processes. In Laurent

  4. A whole process quality control system for energy measuring instruments inspection based on IOT technology

    Science.gov (United States)

    Yin, Bo; Liu, Li; Wang, Jiahan; Li, Xiran; Liu, Zhenbo; Li, Dewei; Wang, Jun; Liu, Lu; Wu, Jun; Xu, Tingting; Cui, He

    2017-10-01

    Electric energy measurement as a basic work, an accurate measurements play a vital role for the economic interests of both parties of power supply, the standardized management of the measurement laboratory at all levels is a direct factor that directly affects the fairness of measurement. Currently, the management of metering laboratories generally uses one-dimensional bar code as the recognition object, advances the testing process by manual management, most of the test data requires human input to generate reports. There are many problems and potential risks in this process: Data cannot be saved completely, cannot trace the status of inspection, the inspection process isn't completely controllable and so on. For the provincial metrology center's actual requirements of the whole process management for the performance test of the power measuring appliances, using of large-capacity RF tags as a process management information media, we developed a set of general measurement experiment management system, formulated a standardized full performance test process, improved the raw data recording mode of experimental process, developed a storehouse automatic inventory device, established a strict test sample transfer and storage system, ensured that all the raw data of the inspection can be traced back, achieved full life-cycle control of the sample, significantly improved the quality control level and the effectiveness of inspection work.

  5. Implementation of quality control systematics for personnel monitoring services

    International Nuclear Information System (INIS)

    Franco, J.O.A.

    1984-01-01

    The implementation of statistical quality control techniques used in industrial practise is proposed to dosimetric services. 'Control charts' and 'sampling inspection' are adapted respectively for control of measuring process and of dose results produced in routine. A chapter on Radiation Protection and Personnel Monitoring was included. (M.A.C.) [pt

  6. Web quality control for lectures: Supercourse and Amazon.com.

    Science.gov (United States)

    Linkov, Faina; LaPorte, Ronald; Lovalekar, Mita; Dodani, Sunita

    2005-12-01

    Peer review has been at the corner stone of quality control of the biomedical journals in the past 300 years. With the emergency of the Internet, new models of quality control and peer review are emerging. However, such models are poorly investigated. We would argue that the popular system of quality control used in Amazon.com offers a way to ensure continuous quality improvement in the area of research communications on the Internet. Such system is providing an interesting alternative to the traditional peer review approaches used in the biomedical journals and challenges the traditional paradigms of scientific publishing. This idea is being explored in the context of Supercourse, a library of 2,350 prevention lectures, shared for free by faculty members from over 150 countries. Supercourse is successfully utilizing quality control approaches that are similar to Amazon.com model. Clearly, the existing approaches and emerging alternatives for quality control in scientific communications needs to be assessed scientifically. Rapid explosion of internet technologies could be leveraged to produce better, more cost effective systems for quality control in the biomedical publications and across all sciences.

  7. USE OF INTELLECTUAL TECHNOLOGIES FOR QUALITY CONTROL OF CURD

    Directory of Open Access Journals (Sweden)

    M. M. Blagoveshchenskaya

    2015-01-01

    Full Text Available In this article, we consider additional method of quality control of curds by organoleptic properties. Method consists in construction of neural network model to estimate quality of curds by input and output parameters. Quality control of curds by organoleptic properties is not necessary according to state standard specification, therefore we use exemplary 5-score scale for organoleptic estimation. Author gives an example of fundamental operation which is necessary for neural networks projection and gives recommendation for integrated hardware/software solution design. This method makes easier quality control of final product because operator can react on digression in the technological process in proper time (use data recommended by neural network, predict quality of final product in case when technological parameters deviate from the norm.

  8. Cold plasma: Quality control and regulatory considerations

    Science.gov (United States)

    In recent years, cold plasma has emerged as a promising antimicrobial treatment for fresh and fresh-cut produce, nuts, spices, seeds, and other foods. Research has demonstrated effective control of human pathogens such as Salmonella, Listeria monocytogenes, Escherichia coli O157:H7, norovirus, and o...

  9. Hippuran-123 I: labelling and quality control

    International Nuclear Information System (INIS)

    Barboza, M.F. de; Colturato, M.T.; Herrerias, R.; Muramoto, E.

    1992-01-01

    The o-iodo hippuric acid labelling with radioiodine is a radiopharmaceutical used with more frequently for evaluation the kidney function. Several reactive kits for labelling with 123 I are prepared. Controls of radiochemical purity and biological distribution are made. The reactive kit of hippuran is kept at 4 C during 2 years. (C.G.C.)

  10. Preparation and quality control of ECD kit

    International Nuclear Information System (INIS)

    Yassin, T.; Dadokh, M.; Almalki, R.

    2005-05-01

    ECD Kit for brain imaging after labeling with technetium 99m was prepared according to an optimum conditions, Each vial contains 1 mg of ECD and 0.155 mg of stannous chloride anhydrous SnCl 2 , 24 mg of Mannitol and 0.5 mg of Na 2 Ca EDTA, The prepared kit showed high quality satisfying the requirements of international pharmacopoeias from the points of physical, chemical, radiochemical and biological purities, and its validity for human injection. And the labeling yield exceeded 95 % with average value of about 97.63 ± 0.89% for 2mCi /2ml radioactivity , This study also showed that each vial content can be labeled with maximum activity of 99m Tc of about 50 mCi (Authors)

  11. The CEA contribution to quality control

    International Nuclear Information System (INIS)

    Rapin, M.; Colomer, J.

    1979-01-01

    The Commissariat a l'Energie Atomique has developed original methods and techniques for testing delicate components of the primary circuit of pressure water reactors. These techniques make use of a very wide range of non destructive testing methods: Eddy currents, particularly multiple frequencies, for testing steam generator tubes, gudgeon and other pins focused ultrasonics for testing all the welds of the reactor vessel and its cover plate, mixed welds of steam vessels and generators, low welds of the pressurizer and gudgeon pins from the inside. On site use is effected with specific machines intended either for inspecting the tube bundles of steam generators under the responsibility of INTERCONTROLE Co., or for the complete examination of the reactor vessel by mixed CEA/INTERCONTROLE crews under the responsibility of the CEA. All these operations are subjected to a programme of quality assurance that provides the guaranty of execution complying with the procedures in force [fr

  12. Quality control activities in the environmental radiology laboratory

    International Nuclear Information System (INIS)

    Llaurado, M.; Quesada, D.; Rauret, G.; Tent, J.; Zapata, D.

    2006-01-01

    During the last twenty years many analytical laboratories have implemented quality assurance systems. A quality system implementation requires documentation of all activities (technical and management), evaluation of these activities and its continual improvement. Implementation and adequate management of all the elements a quality system includes are not enough to guarantee quality of the analytical results generated at a time. That is the aim of a group of specific activities labelled as quality control activities. The Laboratori de Radiologia Ambiental (Environmental Radiology Laboratory; LRA) at the University of Barcelona was created in 1984 to carry out part of the quality control assays of the Environmental Radiology Monitoring Programs around some of the Spanish nuclear power plants, which are developed by the Servei Catala d'Activitats Energetiques (SCAR) and the Consejo de Seguridad Nuclear (CSN), organisations responsible for nuclear security and radiological protection. In these kind of laboratories, given the importance of the results they give, quality control activities become an essential aspect. In order to guarantee the quality of its analytical results, the LRA Direction decided to adopt the international standard UNE-EN ISO/IEC 17025 for its internal quality system and to accreditate some of the assays it carries out. In such as system, it is established, the laboratory shall monitor the validity of tests undertaken and data shall be recorded in such a way that trends are detectable. The present work shows the activities carried out in this way by the LRA, which are: Equipment control activities which in the special case of radiochemical techniques include measurement of backgrounds and blanks as well as periodical control of efficiency and resolution. Activities to assure the specifications settled by method validation, which are testing of reference materials and periodical analysis of control samples. Evaluation of the laboratory work quality

  13. European quality assurance and quality control for cut-off walls and caps

    International Nuclear Information System (INIS)

    Jefferis, S.A.

    1997-01-01

    Cut-off walls and caps both may be seriously compromised by small areas of substandard materials or work. Quality assurance/quality control is therefore of crucial importance and the paper sets out the issues that need to be addressed when designing a quality plan for a containment. Consideration is given to the purpose of the containment, the parameters to be controlled, specifications and standards and tests on raw and manufactured materials and on the in-situ containment. It is not the purpose of the paper to give detailed test procedures but rather to identify the questions that must be answered to develop a quality plan

  14. Descriptive study of the quality control in mammography; Estudio descriptivo del control de calidad en mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E.; Perdigon C, G.M.; Casian C, G.A.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M. [UAM, Xochimilco 14000 Mexico D.F. (Mexico)

    2005-07-01

    The goal of mammography is to provide contrast between a lesion that is possible residing within the breast and normal surrounding tissue. Quality control is essential for maintaining the contrast imaging performance of a mammography system and incorporate tests that are relevant in that they are predictive of future degradation of contrast imaging performance. These tests will also be done at frequency that is high enough to intercept most drifts in quality imaging or performance before they become diagnostically significant. The quality control study has as objective to describe the results of the assessment of quality imaging elements (film optical density, contrast (density difference), uniformity, resolution and noise) of 62 mammography departments without quality control program and comparison these results with a mammography reference department with a quality control program. When comparing the results they allow seeing the clinical utility of to have a quality control program to reduce the errors of mammography interpretation. (Author)

  15. Quality control of fireproof coatings for reinforced concrete structures

    Science.gov (United States)

    Gravit, Marina; Dmitriev, Ivan; Ishkov, Alexander

    2017-10-01

    The article analyzes methods of quality inspection of fireproof coatings (work flow, measuring, laboratory, etc.). In modern construction there is a problem of lack of distinct monitoring for the fire protection testing. There is a description of this testing for reinforced concrete structures. The article shows the results of calculation quality control of hatches as an example of fireproof coating for reinforced concrete structures.

  16. Academic Quality Control in Nigerian Universities: Exploring Lecturers' Perceptions

    Science.gov (United States)

    Obiekezie, E. O.; Ejemot-Nwadiaro, R. I.; Essien, M. I.; Timothy, A. Essien

    2014-01-01

    The level of job performance, international comparability and competitiveness of Nigerian university graduates are burning issues. Consequently, the academic quality of Nigerian universities has come under severe criticism. Since university lecturers are key players in quality control in universities, this study explored their perceptions of…

  17. Housing tenancy,data management and quality control

    NARCIS (Netherlands)

    Smeets, J.J.A.M.; Timmermans, H.J.P.

    1993-01-01

    This paper deal s with housing tenancy, data management and quality control. The proposed method is focused on quality characteristics of housing estates in view of rentability risks. It entails a cycle of registration, analysis and implementation of measures. The starting point is the behaviour of

  18. Quality control for diagnostic oral microbiology laboratories in European countries

    NARCIS (Netherlands)

    Rautemaa-Richardson, R.; van der Reijden, W.A.; Dahlen, G.; Smith, A.J.

    2011-01-01

    Participation in diagnostic microbiology internal and external quality control (QC) processes is good laboratory practice and an essential component of a quality management system. However, no QC scheme for diagnostic oral microbiology existed until 2009 when the Clinical Oral Microbiology (COMB)

  19. Quality Assurance and Control in Laboratory using Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Chung, Y. S.; Moon, J. H.; Sun, G. M.; Kim, S. H.; Baek, S. Y.; Lim, J. M.; Kim, H. R.

    2007-01-01

    In accordance with the increment of international trade associated with the worldwide globalization, the importance of quality assurance and control for the commodity produced from one's own country has been stressed. ISO (International Organization for Standards) defines quality control as 'the operational techniques and activities that are used to fulfill the requirements for quality'. Since 1996, the HANARO research reactor in the Korea Atomic Energy Research Institute has been operated thereafter initial critical operation on April 1995. Neutron activation analysis system and applied techniques which is one of a nuclear analytical technologies using reactor neutrons has been developed for user's supporting and the establishment of the quality system for a measurement and analysis, testing and inspection was implemented successfully. On the basis of the qualified NAA system, the test and measurement of more than 1500 samples which is requested from 30 organizations including industrial companies, universities and institutes carried out in NAA laboratory annually. Moreover, as the goal of mutual recognition agreement (MRA) which can be removed a technical barrier in international trade, the objectivity and the confidence of analytical quality in NAA laboratory became established through the installation of international accreditation system by implementing analytical quality system in accordance with international standards in 2001. The aim of the report was to summarize the technical management of introduction, methods and the results for a quality control and assurance which should be performed in NAA technique using the HANARO research reactor. The report will help building up effective quality control strategy in the future

  20. Quality control in the storage of potatoes for industrial processing

    NARCIS (Netherlands)

    Verdijck, G.J.C.; Tijskens, L.M.M.

    2003-01-01

    A novel control structure for a potato storage facility is presented that is directly geared at the optimal preservation of product quality. The quality of the stored potatoes is defined as frying colour that depends on sugar concentration. The optimal storage conditions are estimated using models

  1. Computer-supported quality control in X-ray diagnosis

    International Nuclear Information System (INIS)

    Maier, W.; Klotz, E.

    1989-01-01

    Quality control of X-ray facilities in radiological departments of large hospitals is possible only if the instrumentation used for measurements is interfaced to a computer. The central computer helps to organize the measurements as well as analyse and record the results. It can also be connected to a densitometer and camera for evaluating radiographs of test devices. Other quality control tests are supported by a mobile station with equipment for non-invasive dosimetry measurements. Experience with a computer-supported system in quality control of film and film processing is described and the evaluation methods of ANSI and the German industrial standard DIN are compared. The disadvantage of these methods is the exclusion of film quality parameters, which can make processing control almost worthless. (author)

  2. Research Ship Oceanus Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Oceanus Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  3. Research Ship Melville Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Melville Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  4. Research Ship Atlantic Explorer Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Atlantic Explorer Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  5. Research Ship Healy Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Healy Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  6. Research Ship Knorr Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Knorr Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  7. Research Ship Nathaniel B. Palmer Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Nathaniel B. Palmer Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and...

  8. NOAA Ship Delaware II Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Delaware II Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  9. Research Ship Atlantis Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Atlantis Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  10. NOAA Ship Pisces Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Pisces Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System (SAMOS)...

  11. Research Ship Robert Gordon Sproul Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Robert Gordon Sproul Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and...

  12. Research Ship Roger Revelle Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Roger Revelle Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  13. NOAA Ship Fairweather Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Fairweather Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  14. NOAA Ship Bell M. Shimada Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Bell M. Shimada Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  15. NOAA Ship Hi'ialakai Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Hi'ialakai Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  16. Research Ship New Horizon Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship New Horizon Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  17. NOAA Ship Ronald Brown Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Ronald Brown Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  18. Research Ship Aurora Australis Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Aurora Australis Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  19. NOAA Ship Miller Freeman Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Miller Freeman Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  20. NOAA Ship David Starr Jordan Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship David Starr Jordan Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  1. NOAA Ship Henry B. Bigelow Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Henry B. Bigelow Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  2. NOAA Ship Oscar Dyson Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Oscar Dyson Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  3. NOAA Ship Oscar Elton Sette Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Oscar Elton Sette Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  4. Research Ship Kilo Moana Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Kilo Moana Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  5. NOAA Ship Nancy Foster Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Nancy Foster Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  6. NOAA Ship Gordon Gunter Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Gordon Gunter Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  7. Research Ship Southern Surveyor Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Southern Surveyor Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  8. NOAA Ship Rainier Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Rainier Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  9. Research Ship Tangaroa Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Tangaroa Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  10. NOAA Ship Ka'imimoana Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Ka'imimoana Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  11. NOAA Ship Oregon II Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Oregon II Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  12. Preparation and quality control of technetium-99m radiopharmaceuticals

    International Nuclear Information System (INIS)

    Samuels, D.L.

    1978-11-01

    Appropriate procedures for the production and quality control of technetium-99m based radiopharmaceuticals in hospital radiopharmacy consistent with the recently published Australian Code of Good Manufacturing Practice are discussed

  13. VERIFICATION TESTING OF AIR POLLUTION CONTROL TECHNOLOGY QUALITY MANAGEMENT PLAN

    Science.gov (United States)

    This document is the basis for quality assurance for the Air Pollution Control Technology Verification Center (APCT Center) operated under the U.S. Environmental Protection Agency (EPA). It describes the policies, organizational structure, responsibilities, procedures, and qualit...

  14. Calibration and quality control for personnel dose meter

    International Nuclear Information System (INIS)

    Wu Rongtao; Zhang Dianqin

    1999-01-01

    Calibration and quality control are the important aspects to assure thermoluminescence dose measurement compliance with the technical standards. The author discussed some problems to implement technical standards and regulations

  15. Mössbauer spectroscopy and quality control in ferrate technology

    International Nuclear Information System (INIS)

    Dedushenko, S. K.; Perfiliev, Yu. D.; Kulikov, L. A.

    2013-01-01

    This paper describes some prospective reactants for the ferrate technology of water treatment, the ways of their industrial production and the application of the Mössbauer spectroscopy for their quality control.

  16. Research Ship T. G. Thompson Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship T. G. Thompson Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  17. Research Ship Laurence M. Gould Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Laurence M. Gould Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  18. NOAA Ship Okeanos Explorer Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Okeanos Explorer Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  19. Physical chemical quality control of the molybdenum technetium generator

    International Nuclear Information System (INIS)

    Olive, E.; Cruz, J.; Isaac, M.; Gamboa, R.; D'Alessandro, K.; Desdin, L.F.

    1995-01-01

    Comparative operational procedure imported molybdenum technetium generators have been made. Procedures for determination of chemical, radiochemical and radionuclidic purities that may be applied in Hospital's laboratories and in the quality control of generators production are developed

  20. Quality controls of radiopharmaceuticals used in nuclear medicine

    International Nuclear Information System (INIS)

    Gomez de Castiglia, S.I.; Fraga de Suarez, A.H.; Mitta, A.E.A.

    1981-01-01

    Chromatographic quality controls for Tc-99m; In-113m; I-131; Tl-201 and Ga-67 radiopharmaceuticals are described. Moreover, a chromatographic system which allows to separate different radiopharmaceuticals from In-113m is pointed out. (author) [es

  1. Quality control of plane and tomographic gamma cameras

    International Nuclear Information System (INIS)

    Moretti, J.L.; Roussi, A.

    1993-01-01

    In this article, the authors present different methods of gamma camera quality control in matters of uniformity, spatial resolution, spatial linearity, sensitivity, energy resolution, counting rate performance, SPECT parameters. The authors refer mainly to NEMA standards. 14 figs., 8 tabs

  2. Quality control of radiation therapy in clinical trials

    International Nuclear Information System (INIS)

    Kramer, S.; Lustig, R.; Grundy, G.

    1983-01-01

    The RTOG is a group of participating institutions which has a major interest in furthering clinical radiation oncology. They have formulated protocols for clinical investigation in which radiation therapy is the major modality of treatment. In addition, other modalities, such as chemotherapy, radiation sensitizers, and hyperthermia, are used in combined approach to cancer. Quality control in all aspects of patient management is necessary to insure quality data. These areas include evaluation of pathology, physics, and dosimetry, and clinical patient data. Quality control is both time consuming and expensive. However, by dividing these tasks into various levels and time frames, by using computerized data-control mechanisms, and by employing appropriate levels of ancillary personnel expertise, quality control can improve compliance and decrease the cost of investigational trials

  3. Six Sigma Quality Management System and Design of Risk-based Statistical Quality Control.

    Science.gov (United States)

    Westgard, James O; Westgard, Sten A

    2017-03-01

    Six sigma concepts provide a quality management system (QMS) with many useful tools for managing quality in medical laboratories. This Six Sigma QMS is driven by the quality required for the intended use of a test. The most useful form for this quality requirement is the allowable total error. Calculation of a sigma-metric provides the best predictor of risk for an analytical examination process, as well as a design parameter for selecting the statistical quality control (SQC) procedure necessary to detect medically important errors. Simple point estimates of sigma at medical decision concentrations are sufficient for laboratory applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Suggestion for improvement of PET quality control tests in Brazil

    International Nuclear Information System (INIS)

    Ferreira, Fernanda C.L.; Magalhaes, Cinthia M.S.; Souza, Divanizia N.

    2009-01-01

    Nowadays nuclear medicine has a considerable importance among the other medical specialties. This medical specialty utilizes high-tech equipment for imaging in the diagnosis, obtaining information on the clinical functionality of organs and systems of the human body through the use of radioisotopes . In view of the importance of guaranteeing the image quality in SPECT and PET systems, enabling patients not repeat exams due to lack of quality control of equipment used in nuclear medicine, this paper aims to present a possible suggestion to update the quality control tests needed for quality assurance of nuclear medicine services. They were considered the requirements of the National Commission of Nuclear Energy (CNEN) and the National Health Surveillance Agency (ANVISA) in Brazil. The minimum requirements to be defined for inclusion of quality control tests on PET in the standard CNEN are extremely important because they will guide the evaluation of PET systems, determining the quality control tests to be performed. And those tests for PET will be a regulatory requirement by the CNEN and ANVISA. As the National Health Surveillance Agency has already publication of RDC 38 with recommendations for services of nuclear medicine. This study will continue with evaluation of PET systems and presenting the tests of quality control with additional objects and simulators to ensure safety in PET systems have not standardized in nuclear medicine services in Brazil. (author)

  5. Production control system specified quality sausage products

    Directory of Open Access Journals (Sweden)

    A. V. Tokarev

    2016-01-01

    Full Text Available The problem of management of production target in technological system of production of sausages of the set quality is considered in article. Decomposition of technological system is considered. Functions of management are allocated: formation of an optimum compounding of forcemeat, expert analysis of a compounding, laboratory analysis of a compounding and its statement. Information technology of interaction of these functions is offered. The mathematical problem definition of finding of an optimum compounding meat product with use of possible substitutes of ingredients is presented. This mathematical problem is a classical linear programming problem whose solution has the standard program. Since the manufacture of the finished product are various nonlinear effects are taken into account at the present time it is practically impossible, the methodology provided in this operation "Expert analysis of the formulation" and "Laboratory analysis of the finished product." An example of calculating the optimum alternative base recipe "Sausages “Viennese with cheese”" TS 9213-010-40155161-2002. For an alternative formulation demands were made at a cost of meat, the ingredient composition, as well as the final product organoleptic and physic-chemical indicators should comply with regulatory requirements "Sausages “Viennese with cheese”" TS 9213-010-40155161-2002. Indicator acid activity (pH calculated stuffing formulation should be in the range 6.0-6.3. As a partial replacement for the main raw material have been proposed acceptable substitutes. It was necessary to calculate on the basis of the formulation "Sausages “Viennese with cheese”" TS 9213-010-40155161-2002 optimal price and quality alternative formulation. As a result of depreciation of the value of alternative stuffing recipe was 14,5 % when all of the restrictions on the consumer properties. The proposed information technology implemented in the software package "Multi

  6. Quality control of injection moulded micro mechanical parts

    DEFF Research Database (Denmark)

    Gasparin, Stefania; Tosello, Guido; Hansen, Hans Nørgaard

    2009-01-01

    Quality control of micro components is an increasing challenge. Smaller mechanical parts are characterized by smaller tolerance to be verified. This paper focuses on the dimensional verification of micro injection moulded components selected from an industrial application. These parts are measured...... using an Optical Coordinate Measuring Machine (OCMM), which guarantees fast surface scans suitable for in line quality control. The uncertainty assessment of the measurements is calculated following the substitution method. To investigate the influence parameters in optical coordinate metrology two...

  7. Quality control of rain data used for urban runoff systems

    DEFF Research Database (Denmark)

    Jørgensen, H. K.; Rosenørn, S.; Madsen, Henrik

    1998-01-01

    for collection and quality control of rain data from a network of tipping bucket rain gauges in Denmark carried out by the Danish Meteorological Institute. During rain, the RIMCO gauge counts the number of tips teach of 0.2 mm of precipitation) every minute, The quality control of the rain data includes...... an automatic and a manual bit marking, where the automatic control basically is pointing out minutes with extreme intensities. In the manual control, the maximum intensities as well as the daily totals of precipitation are inspected, using weather charts, intensity plots and precipitation sums of nearby...

  8. COLLABORATIVE TRIAL AND QUALITY CONTROL IN CHEMICAL ANALYSIS

    Directory of Open Access Journals (Sweden)

    Narsito Narsito

    2010-06-01

    Full Text Available Abstract                                                             This paper deals with some practical problems related to the quality of analytical chemical data usually met in practice. Special attention is given to the topic of quality control in analytical chemistry, since analytical data is one of the primary information from which some important scientifically based decision are to be made. The present paper starts with brief description on some fundamental aspects associated with quality of analytical data, such as sources of variation of analytical data, criteria for quality of analytical method, quality assurance in chemical analysis. The assessment of quality parameter for analytical method like the use of standard materials as well as standard methods is given. Concerning with the quality control of analytical data, the use of several techniques, such as control samples and control charts, in monitoring analytical data in quality control program are described qualitatively.  In the final part of this paper, some important remarks for the preparation of collaborative trials, including the evaluation of accuracy and reproducibility of analytical method are also given Keywords: collaborative trials, quality control, analytical data Abstract                                                             This paper deals with some practical problems related to the quality of analytical chemical data usually met in practice. Special attention is given to the topic of quality control in analytical chemistry, since analytical data is one of the primary information from which some important scientifically based decision are to be made. The present paper starts with brief description on some fundamental aspects associated with quality of analytical data, such as sources of variation of analytical data, criteria for quality of

  9. Quality control in a modern XRF laboratory

    International Nuclear Information System (INIS)

    Grigolato, E.

    2002-01-01

    Full text: In the last twenty years manufacturers have improved instruments significantly. Many of these advances have come from the computing power now available using a PC. Unfortunately, now in many laboratories, the senior analyst is responsible for multiple instruments and may have little experience in XRF. It is now common for instruments to be calibrated by consultants and used in a black box mode. The session will look at a range of tools for monitoring and controlling your XRF from date of installation, thru calibration, routine use and maintenance. Discussion of user problems is an integral part of the session. Copyright (2002) Australian X-ray Analytical Association Inc

  10. Production process and quality control for the HTTR fuel

    International Nuclear Information System (INIS)

    Yoshimuta, S.; Suzuki, N.; Kaneko, M.; Fukuda, K.

    1991-01-01

    Development of the production and inspection technology for High Temperature Engineering Test Reactor (HTTR) fuel has been carried out by cooperative work between Japan Atomic Energy Research Institute (JAERI) and Nuclear Fuel Industries, Ltd (NFI). The performance and the quality level of the developed fuel are well established to meet the design requirements of the HTTR. For the commercial scale production of the fuel, statistical quality control and quality assurance must be carefully considered in order to assure the safety of the HTTR. It is also important to produce the fuel under well controlled process condition. To meet these requirements in the production of the HTTR fuel, a new production process and quality control system is to be introduced in the new facilities. The main feature of the system is a computer integrated control system. Process control data at each production stage of products and semi-products are all gathered by terminal computers and processed by a host computer. The processed information is effectively used for the production, quality and accountancy control. With the aid of this system, all the products will be easily traceable from starting materials to final stages and the statistical evaluation of the quality of products becomes more reliable. (author). 8 figs

  11. [Our experience with outside laboratory quality control].

    Science.gov (United States)

    Dochev, D; Arakasheva, V; Nashkov, A; Tsachev, K

    1979-01-01

    The results from the national outside laboratory qualitative control of the clinical diagnostic laboratory investigations for the period September 1975 -- May 1977 were described. The following interlaboratory discrepancy was found on base of a systematic analysis of the data from the last two ring-like check-ups, November 1976 and May 1977, exressed by the variation coefficient (V.C. %); total protein, sodium, potassium and chlorides -- under 10%; cholesterol, urea and total fats -- between 10 and 20%; calcium, phosphorus, iron and creatinine -- over 20%. The highest per cent of admissible results are found with total protein -- to 85%; cholesterol -- to 70.38%; glucosa -- to 73.17%, urea -- to 69.23%, potassium -- to 59.46%, chlorides -- to 57.9%. With sodium, phosphorus, calcium, iron creatinine and uric acid the "admissibility" fluctuates about or under 50 per cent. The values of the qualitative-control indices discussed are comparable with the values obtained from them in the interlaboratory comparisons of other countries.

  12. Research review: Indoor air quality control techniques

    International Nuclear Information System (INIS)

    Fisk, W.J.

    1986-10-01

    Techniques for controlling the concentration of radon, formaldehyde, and combustion products in the indoor air are reviewed. The most effective techniques, which are generally based on limiting or reducing indoor pollutant source strengths, can decrease indoor pollutant concentrations by a factor of 3 to 10. Unless the initial ventilation rate is unusually low, it is difficult to reduce indoor pollutant concentrations more than approximately 50% by increasing the ventilation rate of an entire building. However, the efficiency of indoor pollutant control by ventilation can be enhanced through the use of local exhaust ventilation near concentrated sources of pollutants, by minimizing short circuiting of air from supply to exhaust when pollutant sources are dispersed and, in some situations, by promoting a displacement flow of air and pollutants toward the exhaust. Active air cleaning is also examined briefly. Filtration and electrostatic air cleaning for removal of particles from the indoor air are the most practical and effective currently available techniques of air cleaning. 49 refs., 7 figs

  13. Quality control and quality assurance in individual monitoring of ionising radiations

    International Nuclear Information System (INIS)

    Dutt, J.C.; Lindborg, L.

    1994-01-01

    This paper describes the programmes and approaches that are to be considered in developing and introducing quality assurance and quality control procedures in individual monitoring services. Quality assurance and quality control in individual monitoring services are essential to maintain quality and are of increasing importance in order to meet the requirements of national regulations and international standards and guidelines. It is recommended here that all organisations offering individual monitoring services should run their services based on the principles of Quality System as given in the European Standard EN45001 and maintain a property resources QA/QC programme as an integral part of their operations. All aspects of QA/QC in individual monitoring services starting from the initial selection, installation, calibration, and operation to the final products including dose reporting, dose record keeping, dealing with customers' complaints and product liability issues have been discussed. (Author)

  14. Quality control of scintillation cameras (planar and SPECT)

    International Nuclear Information System (INIS)

    Shaekhoon, E.S.

    2008-01-01

    Regular quality control is one of the corner stones of nuclear medicine and a prerequisite for adequate diagnostic imaging. Many papers have been published on quality control of planar and SPECT imaging system up to now, however only minor attenuation has been given to the assessment of the performance of imaging systems. In this research we are going to discuss a comprehensive set of test procedures including regular quality control. Our purpose is to go through analysis of the methods and results then to test our hypothesis which state that there is strong relationship between regular and proper evaluation of quality control and the continuity of better medical services in nuclear medicine department. The selection of the tests is discussed and the tests are described, then results are presented. In addition action thresholds are proposed. The quality control tests can be applied to systems with either a moving detector or a moving image table, and to both detector with a large field of view and detectors with a small field of view. The tests presented on this research do not required special phantoms or sources other than those used for quality control of stationary gamma camera and SPECT. They can be applied for acceptance testing and for performance testing in a regular quality assurance program. The data has been evaluated based on me diso software in comparing with IAEA expert software and system specification within the reference values. Our final results confirm our hypothesis, there are some comments about the characteristics and performance of this system that being observed and solved, then a departmental protocol for routine quality control (Q.C) has being established.(Author)

  15. Analytic Methods Used in Quality Control in a Compounding Pharmacy.

    Science.gov (United States)

    Allen, Loyd V

    2017-01-01

    Analytical testing will no doubt become a more important part of pharmaceutical compounding as the public and regulatory agencies demand increasing documentation of the quality of compounded preparations. Compounding pharmacists must decide what types of testing and what amount of testing to include in their quality-control programs, and whether testing should be done in-house or outsourced. Like pharmaceutical compounding, analytical testing should be performed only by those who are appropriately trained and qualified. This article discusses the analytical methods that are used in quality control in a compounding pharmacy. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  16. Concept and realization of quality control in FRG

    International Nuclear Information System (INIS)

    Odoj, R.; Martens, B.R.; Warnecke, E.

    1987-01-01

    Radioactive waste packages to be disposed of in FRG must meet the waste acceptance requirement of the repository. Compliance with the waste acceptance requirements must be checked by a quality control. Fourteen relevant properties are necessary to be assayed. The quality control group supports the observance of the waste acceptance requirements by the following measures: -checking of the documentation of the waste producers; -random tests at conditioned radioactive wastes; -qualification of conditioning processes; -control of the qualified processes by inspections. The relevant properties of disposal are termed and their checking by non-destructive and if necessary destructive test methods will be explained as well as quality control by process control, i.e. qualification of conditioning processes by instrumentation and documentation. The mobile and stationary testing facilities will be outlined

  17. Impacts of pollution controls on air quality in Beijing during the 2008 Olympic Games.

    Science.gov (United States)

    Shen, Jianlin; Tang, Aohan; Liu, Xuejun; Kopsch, Jenny; Fangmeier, Andreas; Goulding, Keith; Zhang, Fusuo

    2011-01-01

    Air pollution has become one of the main environmental concerns in China since the 1980s due to China's rapid economic growth and resultant pollution. However, it is difficult to directly evaluate the anthropogenic contribution to air pollution in China. The 2008 Olympic Games in Beijing provided a unique opportunity for testing the contribution of anthropogenic pollution because of the clean-up controls on air quality in Beijing enforced over the period of the Games. In this case study, we monitored the concentrations of major air pollutants before, during, and after the Olympics at a suburban site in Beijing. Atmospheric concentrations of PM10, PM2.5, NH3, NO2, SO2, and the particulate ions NH4+, NO3-, SO4(2-) Ca2+, Mg2+, and K+ all decreased during the Olympic period because of strict emission controls, compared with the same period from 2005 to 2007. For example, the average PM10 concentration (61 microg m(-3)) during the Olympics was only 37% of that (166 microg m(-3)) in the same month (August) from 2005 to 2007. However, just 1 mo and 1 yr after the Games had ended, mean concentrations of these pollutants had increased significantly again. This rapid "recovery' of air pollutant concentrations after the Olympics suggests that China needs to implement long-lasting decreases in its air pollution in Beijing and other major cities.

  18. Quality control of conventional radiographic facilities in Kinshasa

    International Nuclear Information System (INIS)

    Woto, M.L.; Lukanda, M.V.; Mulumba, L.C.P.; Palangu

    2009-01-01

    The continuous development of medical applications of ionizing radiation, due to the benefit derived by diagnostic or therapeutic patients, their diversity, ease of implementation, explains the importance of medical exposure. The latter is currently the leading cause of human exposure to artificial origin. The purpose of this study is to contribute to the optimization of radiographic facilities in the city of Kinshasa. This study has revealed that city of Kinshasa has an average of 122 medical training with conventional radiology facilities distributed in six districts of health. Of the 122 facilities, only 30 (or 24.59%) are controlled from the point of view of quality assurance. Some generators and X-ray tubes are respectively controlled adjustment and de centered, and other devices are cannibalized. So, nationally and particularly in Kinshasa, quality control equipment and diagnostic facilities is at a generally delayed compared with international recommendations of X W. Major efforts must be made at government level to raise awareness and establish a quality assurance program in diagnostic radiology. An awareness of the entire medical profession and the competent administrative authorities of medical devices could be beneficial to the quality of care delivered to patients, limiting radiation exposure and improving image quality and only the financial balance of the health sector. The delivery of quality care passes through the justification of acts, the development and dissemination of good practice references and the establishment of quality control radiological installations.

  19. Internal cost control on the ecological quality of products

    Directory of Open Access Journals (Sweden)

    N.P. Syroid

    2018-04-01

    Full Text Available To improve the environmental quality of products due attention should be paid to control the processes related to environmental quality input of the product. The results of the study help to state the purpose and objectives of the control, also to define objects for internal control of operations cost of environmental quality. So, we believe that the main purpose of internal cost control on the ecological quality of products is the establishment of the correctness and legality of business operations, prevention of violations and abuses in the expenditure of natural, labour, material and financial resources to ensure the minimization of negative impact on the health of consumers and the environment. The basic objectives of internal control of expenditure are brought forward, but it should be noted that they can vary and depend on the size, structure, spheres and types of economic activity of the enterprise, the requirements of management personnel. In the process of identifying the objects of control of environmental quality it should be noted that this list is not exhaustive, but it is most relevant to highlight objects such as genetically modified organisms and waste production. Also the subjects of cost control to environmental quality, their functions and the information base for monitoring are determined. Proper organization of the process of internal cost control on the ecological quality of products would benefit from a clear documentation of transactions, timely and complete registration of accounting data in the registers, the true reflection of information in managerial financial reporting and ensure reduction of the negative impact on the health of consumers and the environment.

  20. The application of statistical process control in linac quality assurance

    International Nuclear Information System (INIS)

    Li Dingyu; Dai Jianrong

    2009-01-01

    Objective: To improving linac quality assurance (QA) program with statistical process control (SPC) method. Methods: SPC is applied to set the control limit of QA data, draw charts and differentiate the random and systematic errors. A SPC quality assurance software named QA M ANAGER has been developed by VB programming for clinical use. Two clinical cases are analyzed with SPC to study daily output QA of a 6MV photon beam. Results: In the clinical case, the SPC is able to identify the systematic errors. Conclusion: The SPC application may be assistant to detect systematic errors in linac quality assurance thus it alarms the abnormal trend to eliminate the systematic errors and improves quality control. (authors)

  1. Quality control of the documentation process in electronic economic activities

    Directory of Open Access Journals (Sweden)

    Krutova A.S.

    2017-06-01

    Full Text Available It is proved that the main tool that will provide adequate information resources e economic activities of social and economic relations are documenting quality control processes as the basis of global information space. Directions problems as formation evaluation information resources in the process of documentation, namely development tools assess the efficiency of the system components – qualitative assessment; development of mathematical modeling tools – quantitative evaluation. A qualitative assessment of electronic documentation of economic activity through exercise performance, efficiency of communication; document management efficiency; effectiveness of flow control operations; relationship management effectiveness. The concept of quality control process documents electronically economic activity to components which include: the level of workflow; forms adequacy of information; consumer quality documents; quality attributes; type of income data; condition monitoring systems; organizational level process documentation; attributes of quality, performance quality consumer; type of management system; type of income data; condition monitoring systems. Grounded components of the control system electronic document subjects of economic activity. Detected components IT-audit management system economic activity: compliance audit; audit of internal control; detailed multilevel analysis; corporate risk assessment methodology. The stages and methods of processing electronic transactions economic activity during condition monitoring of electronic economic activity.

  2. Chronic Low Quality Sleep Impairs Postural Control in Healthy Adults.

    Science.gov (United States)

    Furtado, Fabianne; Gonçalves, Bruno da Silva B; Abranches, Isabela Lopes Laguardia; Abrantes, Ana Flávia; Forner-Cordero, Arturo

    2016-01-01

    The lack of sleep, both in quality and quantity, is an increasing problem in modern society, often related to workload and stress. A number of studies have addressed the effects of acute (total) sleep deprivation on postural control. However, up to date, the effects of chronic sleep deficits, either in quantity or quality, have not been analyzed. Thirty healthy adults participated in the study that consisted of registering activity with a wrist actigraph for more than a week before performing a series of postural control tests. Sleep and circadian rhythm variables were correlated and the sum of activity of the least active 5-h period, L5, a rhythm variable, obtained the greater coefficient value with sleep quality variables (wake after sleep onset WASO and efficiency sleep). Cluster analysis was performed to classify subjects into two groups based on L5 (low and high). The balance tests scores used to asses postural control were measured using Biodex Balance System and were compared between the two groups with different sleep quality. The postural tests were divided into dynamic (platform tilt with eyes open, closed and cursor) and static (clinical test of sensory integration). The results showed that during the tests with eyes closed, the group with worse sleep quality had also worse postural control performance. Lack of vision impairs postural balance more deeply in subjects with chronic sleep inefficiency. Chronic poor sleep quality impairs postural control similarly to total sleep deprivation.

  3. [Pharmaceutical product quality control and good manufacturing practices].

    Science.gov (United States)

    Hiyama, Yukio

    2010-01-01

    This report describes the roles of Good Manufacturing Practices (GMP) in pharmaceutical product quality control. There are three keys to pharmaceutical product quality control. They are specifications, thorough product characterization during development, and adherence to GMP as the ICH Q6A guideline on specifications provides the most important principles in its background section. Impacts of the revised Pharmaceutical Affairs Law (rPAL) which became effective in 2005 on product quality control are discussed. Progress of ICH discussion for Pharmaceutical Development (Q8), Quality Risk Management (Q9) and Pharmaceutical Quality System (Q10) are reviewed. In order to reconstruct GMP guidelines and GMP inspection system in the regulatory agencies under the new paradigm by rPAL and the ICH, a series of Health Science studies were conducted. For GMP guidelines, product GMP guideline, technology transfer guideline, laboratory control guideline and change control system guideline were written. For the GMP inspection system, inspection check list, inspection memo and inspection scenario were proposed also by the Health Science study groups. Because pharmaceutical products and their raw materials are manufactured and distributed internationally, collaborations with other national authorities are highly desired. In order to enhance the international collaborations, consistent establishment of GMP inspection quality system throughout Japan will be essential.

  4. Advanced methods of quality control in nuclear fuel fabrication

    International Nuclear Information System (INIS)

    Onoufriev, Vladimir

    2004-01-01

    Under pressure of current economic and electricity market situation utilities implement more demanding fuel utilization schemes including higher burn ups and thermal rates, longer fuel cycles and usage of Mo fuel. Therefore, fuel vendors have recently initiated new R and D programmes aimed at improving fuel quality, design and materials to produce robust and reliable fuel. In the beginning of commercial fuel fabrication, emphasis was given to advancements in Quality Control/Quality Assurance related mainly to product itself. During recent years, emphasis was transferred to improvements in process control and to implementation of overall Total Quality Management (TQM) programmes. In the area of fuel quality control, statistical control methods are now widely implemented replacing 100% inspection. This evolution, some practical examples and IAEA activities are described in the paper. The paper presents major findings of the latest IAEA Technical Meetings (TMs) and training courses in the area with emphasis on information received at the TM and training course held in 1999 and other latest publications to provide an overview of new developments in process/quality control, their implementation and results obtained including new approaches to QC

  5. Chronic Low Quality Sleep Impairs Postural Control in Healthy Adults.

    Directory of Open Access Journals (Sweden)

    Fabianne Furtado

    Full Text Available The lack of sleep, both in quality and quantity, is an increasing problem in modern society, often related to workload and stress. A number of studies have addressed the effects of acute (total sleep deprivation on postural control. However, up to date, the effects of chronic sleep deficits, either in quantity or quality, have not been analyzed. Thirty healthy adults participated in the study that consisted of registering activity with a wrist actigraph for more than a week before performing a series of postural control tests. Sleep and circadian rhythm variables were correlated and the sum of activity of the least active 5-h period, L5, a rhythm variable, obtained the greater coefficient value with sleep quality variables (wake after sleep onset WASO and efficiency sleep. Cluster analysis was performed to classify subjects into two groups based on L5 (low and high. The balance tests scores used to asses postural control were measured using Biodex Balance System and were compared between the two groups with different sleep quality. The postural tests were divided into dynamic (platform tilt with eyes open, closed and cursor and static (clinical test of sensory integration. The results showed that during the tests with eyes closed, the group with worse sleep quality had also worse postural control performance. Lack of vision impairs postural balance more deeply in subjects with chronic sleep inefficiency. Chronic poor sleep quality impairs postural control similarly to total sleep deprivation.

  6. Direct product quality control for energy efficient climate controlled transport of agro-material

    NARCIS (Netherlands)

    Verdijck, G.J.C.; Preisig, H.A.; Straten, van G.

    2005-01-01

    A (model-based) Product Quality Controller is presented for climate controlled operations involving agro-material, such as storage and transport. This controller belongs to the class of Model Predictive Controllers and fits in a previously developed hierarchical control structure. The new Product

  7. Quality control in diagnostic mammography: myths, realities and their importance in the final image quality

    International Nuclear Information System (INIS)

    Mora Rodriguez, Patricia

    2011-01-01

    Mammography is the most used tool for early detection of breast cancer and reduce mortality from this cause. Studies with ionizing radiation it is important that be justified and provide a quality image to make the diagnosis, to get more benefits and fewer risks. The problem is the difficult to obtain an image of the breast. Therefore, the commitment to quality mammography is to maximize the contrast, definition, resolution and reliability, thus minimizing noise and dose. A mammogram performed without quality don't detect early breast cancer and the study doesn't have sense. Quality mammography requires trained and experienced staff, modern equipment and in good conditions, correct positioning, right technical factors and appropriate viewing conditions. In addition, quality programs are required to reach to ensure quality, control in testing techniques and image quality. (author) [es

  8. Modular PNML revisited: Some ideas for strict typing

    DEFF Research Database (Denmark)

    Kindler, Ekkart

    2007-01-01

    The Petri Net Markup Language (PNML) is currently standardised by ISO/IEC JTC1/SC7 WG 19 as Part 2 of ISO/IEC 15909. But, there is not yet a mechanism for structuring large Petri nets and for constructing Petri nets from modules. To this end, modular PNML has been proposed some time ago. But, mod...... of Petri net, but still has a strict type system. This paper focuses on the ideas and concepts; the technical details still need to be worked out. To this end, this paper also raises some issues and questions that need to be discussed before standardising modular PNML....

  9. Relaxation Methods for Strictly Convex Regularizations of Piecewise Linear Programs

    International Nuclear Information System (INIS)

    Kiwiel, K. C.

    1998-01-01

    We give an algorithm for minimizing the sum of a strictly convex function and a convex piecewise linear function. It extends several dual coordinate ascent methods for large-scale linearly constrained problems that occur in entropy maximization, quadratic programming, and network flows. In particular, it may solve exact penalty versions of such (possibly inconsistent) problems, and subproblems of bundle methods for nondifferentiable optimization. It is simple, can exploit sparsity, and in certain cases is highly parallelizable. Its global convergence is established in the recent framework of B -functions (generalized Bregman functions)

  10. Quality control and quality assurance of micromegas readout boards for the ATLAS New Small Wheel

    CERN Document Server

    Nanda, Amit

    2016-01-01

    The resistive anode boards of the Micromegas detectors for ATLAS NSW upgrade, will be produced in industries. The anode boards will be thoroughly evaluated at CERN following a detailed quality control and quality assurance (QA/QC) procedure. The report describes thoroughly the procedures and the design of a small QC tool for easier measurements of electrical properties of the readout boards.

  11. Quality Assurance and Quality Control Practices for Rehabilitation of Sewer and Water Mains

    Science.gov (United States)

    As part of the US Environmental Protection Agency (EPA)’s Aging Water Infrastructure Research Program, several areas of research are being pursued, including a review of quality assurance and quality control (QA/QC) practices and acceptance testing during the installation of reha...

  12. HANDBOOK: QUALITY ASSURANCE/QUALITY CONTROL (QA/QC) PROCEDURES FOR HAZARDOUS WASTE INCINERATION

    Science.gov (United States)

    Resource Conservation and Recovery Act regulations for hazardous waste incineration require trial burns by permit applicants. uality Assurance Project Plan (QAPjP) must accompany a trial burn plan with appropriate quality assurance/quality control procedures. uidance on the prepa...

  13. Quality control/quality assurance testing for joint density and segregation of asphalt mixtures.

    Science.gov (United States)

    2013-04-01

    Longitudinal joint quality control/assurance is essential to the successful performance of asphalt pavements and it has received considerable amount of attention in recent years. The purpose of the study is to evaluate the level of compaction at the ...

  14. Quality control in radiography: a primary responsibility of the technologist

    International Nuclear Information System (INIS)

    Koenig, G.F.

    1973-01-01

    The relationship between quality control in radiography and radiation protection is emphasized. Methods of dose reduction discussed are the 0.1 mm fractional focal spot, the use of high speed intensifying screens, and automatic exposure control. The need for recommendations for the establishment of improved systems of radiography is discussed. The development of revised educational concepts for radiologists is considered. (U.S.)

  15. Does Public Sector Control Reduce Variance in School Quality?

    Science.gov (United States)

    Pritchett, Lant; Viarengo, Martina

    2015-01-01

    Does the government control of school systems facilitate equality in school quality? Whether centralized or localized control produces more equality depends not only on what "could" happen in principle, but also on what does happen in practice. We use the Programme for International Student Assessment (PISA) database to examine the…

  16. Quality control for 12 batch of DTPA-Sn

    International Nuclear Information System (INIS)

    Isaac, M.; Gamboa, R.; Leyva, R.; Hernandez, I.; Turino, D.

    1994-01-01

    The quality control is carry out at 12 batch of DTPA-Sn for labeling with 99 m Tc. The instrumental methods of analysis and control charts were discussed in order to find a warranty time for the product. (author). 2 refs, 3 figs, 1 tab

  17. Statistical Process Control: Going to the Limit for Quality.

    Science.gov (United States)

    Training, 1987

    1987-01-01

    Defines the concept of statistical process control, a quality control method used especially in manufacturing. Generally, concept users set specific standard levels that must be met. Makes the point that although employees work directly with the method, management is responsible for its success within the plant. (CH)

  18. Silicon Sheet Quality is Improved By Meniscus Control

    Science.gov (United States)

    Yates, D. A.; Hatch, A. E.; Goldsmith, J. M.

    1983-01-01

    Better quality silicon crystals for solar cells are possible with instrument that monitors position of meniscus as sheet of solid silicon is drawn from melt. Using information on meniscus height, instrument generates feedback signal to control melt temperature. Automatic control ensures more uniform silicon sheets.

  19. 40 CFR 81.112 - Charleston Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.112 Charleston Intrastate Air Quality Control Region. The Charleston Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... Quality Control Region: Region 1. 81.107Greenwood Intrastate Air Quality Control Region: Region 2. 81...

  20. 40 CFR 81.88 - Billings Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.88 Billings Intrastate Air Quality Control Region. The Metropolitan Billings Intrastate Air Quality Control Region (Montana) has been renamed the Billings Intrastate Air Quality Control... to by Montana authorities as follows: Sec. 481.168Great Falls Intrastate Air Quality Control Region...

  1. Non-strictly black body spectrum from the tunnelling mechanism

    International Nuclear Information System (INIS)

    Corda, Christian

    2013-01-01

    The tunnelling mechanism is widely used to explain Hawking radiation. However, in many cases the analysis used to obtain the Hawking temperature only involves comparing the emission probability for an outgoing particle with the Boltzmann factor. Banerjee and Majhi improved this approach by explicitly finding a black body spectrum associated with black holes. Their result, obtained using a reformulation of the tunnelling mechanism, is in contrast to that of Parikh and Wilczek, who found an emission probability that is compatible with a non-strictly thermal spectrum. Using the recently identified effective state for a black hole, we solve this contradiction via a slight modification of the analysis by Banerjee and Majhi. The final result is a non-strictly black body spectrum from the tunnelling mechanism. We also show that for an effective temperature, we can express the corresponding effective metric using Hawking’s periodicity arguments. Potential important implications for the black hole information puzzle are discussed. -- Highlights: •We review an important result by Banerjee and Majhi on the tunnelling mechanism in the framework of Hawking radiation. •This result is in contrast to another result reported by Parikh and Wilczek. •We introduce the effective state of a black hole. •We explain the contrast via a slight modification of the analysis by Banerjee and Majhi. •We discuss potential important implications for the black hole information puzzle

  2. Seven Basic Tools of Quality Control: An Appropriate Tools for Solving Quality Problems in the Organizations

    OpenAIRE

    Neyestani, Behnam

    2017-01-01

    Dr. Kaoru Ishikawa was first total quality management guru, who has been associated with the development and advocacy of using the seven quality control (QC) tools in the organizations for problem solving and process improvements. Seven old quality control tools are a set of the QC tools that can be used for improving the performance of the production processes, from the first step of producing a product or service to the last stage of production. So, the general purpose of this paper was to...

  3. Analytical techniques and quality control in biomedical trace element research

    DEFF Research Database (Denmark)

    Heydorn, K.

    1994-01-01

    The small number of analytical results in trace element research calls for special methods of quality control. It is shown that when the analytical methods are in statistical control, only small numbers of duplicate or replicate results are needed to ascertain the absence of systematic errors....../kg. Measurement compatibility is obtained by control of traceability to certified reference materials, (C) 1994 Wiley-Liss, Inc....

  4. Emission controls and changes in air quality in Guangzhou during the Asian Games

    Science.gov (United States)

    Liu, Huan; Wang, Xuemei; Zhang, Jinpu; He, Kebin; Wu, Ye; Xu, Jiayu

    2013-09-01

    With the new air quality standards forthcoming in China, the Pearl River Delta region is facing new challenges to achieve its air quality goal. The success of the emission reduction measures introduced by local authorities in the run-up to the Guangzhou Asian Games demonstrated that the Pearl River Delta air quality can be improved by introducing integrated emission reduction measures. This paper combines observation data, emission reduction measures, and air quality simulations that were applied during the Asian Games (12-27 November 2010) to analyze the relationship between emissions and concentrations of pollutants in Guangzhou. The Asian Games abatement strategy totally reduced emissions of 41.1% SO2, 41.9% NOx, 26.5% PM10, 25.8% PM2.5 and 39.7% VOC. The concentrations of SO2, NO2, PM10 and PM2.5 were reduced by 66.8%, 51.3%, 21.5% and 17.1%, respectively. In Guangzhou, the main challenge to be overcome with the new air quality daily requirements is mostly for NO2, PM2.5, and hourly ozone maxima. If pollutants maintain the same concentrations before and after the Asian Games, there will be 47.4% and 31.6% non-attainment days for NO2 and PM2.5 respectively as a period average. Although PM10 concentration can meet the daily limits (150 μg m-3), it is quite difficult to meet the annual limit value (70 μg m-3). One important implication is that the long-term, step-by-step integrated measures of the past six years work better than the strict, intensive, short-term measures on SO2, NO2 and VOC control. Dust control by limiting construction sites and watering the roads can further reduce 12.8% of the PM10 concentration. However, to reduce ambient PM2.5, the abatement strategy should be more complex and extensive. On the contrary, ozone pollution was not improved during the Asian Games, indicating that alleviation strategies should be improved by scientific studies to determine the appropriate control ratio of NO2 and VOC in the Pearl River Delta region.

  5. THE CONCEPTUAL FRAMEWORK OF FORMING THE PRODUCT QUALITY CONTROL STRATEGY OF ROAD-BUILDING ENGINEERING ENTERPRISES

    Directory of Open Access Journals (Sweden)

    Mariia Sadova

    2017-11-01

    Full Text Available The purpose of the work is the need of the theoretical justification and the development of relevant scientific and methodological approaches to the management of the road production quality of machine-building enterprises; it led to the choice of research topics. Methodology. Taking into account the value of existing methods of quality management of road production engineering companies, currently a particular attention requires improvement of the quality control functions: analysis, evaluation, planning and quality control during the operation of road-building equipment, because existing economic practices and quality management approaches are built on classical principles of ISO 9001, and in the practical application do not solve all of the drawbacks of traditional management models, but only smooth them a little. Therefore, the formation of the quality management strategy for the road production of mechanical engineering is essential to ensure the competitiveness of products and enterprises of the road-building complex in the period of development of market relations in the economy. The results showed that the current market conditions impose strict requirements to all production areas of the society. Especially stringent are requirements for the road construction, because the quality of the construction of the subgrade, covering roads and curbs, grading and soil compaction under different conditions of terrain and driving safety depends on people's lives. This factor determines the exceptional quality requirements for roadbuilding equipment, which must be reliable, functional and able to meet the totality of the design and operational characteristics of the road. Further European integration of Ukraine, deepening of external economic relations with the European countries are responsible for the growing needs of the national economy in the development and expansion of the transport network. However, large-scale road construction and repair

  6. Process-based quality for thermal spray via feedback control

    Science.gov (United States)

    Dykhuizen, R. C.; Neiser, R. A.

    2006-09-01

    Quality control of a thermal spray system manufacturing process is difficult due to the many input variables that need to be controlled. Great care must be taken to ensure that the process remains constant to obtain a consistent quality of the parts. Control is greatly complicated by the fact that measurement of particle velocities and temperatures is a noisy stochastic process. This article illustrates the application of quality control concepts to a wire flame spray process. A central feature of the real-time control system is an automatic feedback control scheme that provides fine adjustments to ensure that uncontrolled variations are accommodated. It is shown how the control vectors can be constructed from simple process maps to independently control particle velocity and temperature. This control scheme is shown to perform well in a real production environment. We also demonstrate that slight variations in the feed wire curvature can greatly influence the process. Finally, the geometry of the spray system and sensor must remain constant for the best reproducibility.

  7. Minimal requirements for quality controls in radiotherapy with external beams; Controlli di qualita' essenziali in radioterapia con fasci esterni

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    Physical dosimetric guidelines have been developed by the Italian National Institute of Health study group on quality assurance in radiotherapy to define protocols for quality controls in external beam radiotherapy. While the document does not determine strict rules or firm recommendations, it suggests minimal requirements for quality controls necessary to guarantee an adequate degree of accuracy in external beam radiotherapy. [Italian] Il gruppo di studio Assicurazione di qualita' in radioterapia dell'Istituto Superiore di Sanita' presenta le linee guida per la stesura dei protocolli di controllo di qualita' essenziali necessari a garantire un adeguato livello di accuratezza del trattamento radiante e rappresenta pertanto una parte essenziale del contributo fisico-dosimetrico globale di assicurazione di qualita' in radioterapia con fasci esterni.

  8. EFFECT OF QUALITY CONTROL SYSTEM ON AUDIT QUALITY WITH PROFESSIONAL COMMITMENTS AS A MODERATION VARIABLE

    Directory of Open Access Journals (Sweden)

    Ramadhani R.

    2017-12-01

    Full Text Available This study aims to test the effect of every element of Quality Control System (QCS that is leadership responsibilities for quality on audit, relevant ethical requirements, acceptance and continuance of client relationships and certain engagements, assignment of engagement team, engagement performance, monitoring, and documentation on audit quality as well as to test whether the professional commitment moderate effect of every element of QCS on audit quality. The population was the staff auditors working in public accounting firms domiciled in Jakarta City, especially Central Jakarta area with the drawing of 84 respondents. The statistical method used was SEM PLS with the help of SmartPLS application. The results of this study indicate that from seven elements of QCS, only relevant ethical requirements that affect on audit quality. Furthermore, the study also found that professional commitment cannot moderate the relationship between the seven elements of QCS on audit quality.

  9. Association of adherence to epilepsy quality standards with seizure control.

    Science.gov (United States)

    Moura, Lidia M V R; Mendez, Diego Yacaman; Jesus, Jonathan De; Andrade, Rogger A; Weissman, Joel S; Vickrey, Barbara G; Hoch, Daniel B

    2015-11-01

    We assessed the relationship between adherence to epilepsy quality measures (EQM) and seizure control over 2-3 years in a retrospective cohort study. 6150 patients were identified at two large academic medical centers with a primary or secondary diagnosis of epilepsy, were 18-85 years old and seen in outpatient general neurology or epilepsy units between June 2011 and May 2014. Patients were included if: their initial visit was between June 2011 and June 2012, treatment was with ≥1 anti-seizure drug, there was ≥1 visit per year during the timeframe, and seizure frequency was documented at initial and final visits, yielding 162 patients/1055 visits from which socio-demographic, clinical and care quality data were abstracted. Quality care was assessed as (1) percent adherence to up to 8 eligible EQM, and (2) defect-free care (DFC: adherence to all eligible EQM). Seizure control (SC) was defined as ≥50% reduction in average seizures/month between initial and final visits. Chi-square and t-test compared care quality with seizure control. Logistic regression was used to assess the relationships between SC, quality of care and subspecialist involvement. Care quality, reflected by documentation of seizure frequency, addressing therapeutic interventions, and referral to a comprehensive epilepsy center, all exceeded 80% adherence. Care quality as reflected by documentation of seizure type, etiology or syndrome; assessment of side effects, counseling about epilepsy safety and women's issues, and screening for psychiatric disorders ranged from 40 to 57%. Mean EQM adherence across all applicable measures was associated with greater seizure control (p=0.0098). DFC was low (=8%) and did not covary with seizure control (p=0.55). The SC and non-SC groups only differed on epilepsy etiology (p=0.04). Exploratory analysis showed that mean quality scores are associated with seizure control (OR=4.9 [1.3-18.5], p=0.017) while controlling for the effect of subspecialty involvement

  10. Quality Control Assessment of Radiology Devices in Kerman Province, Iran

    OpenAIRE

    Zahra Jomehzadeh; Ali Jomehzadeh; Mohammad Bagher Tavakoli

    2016-01-01

    Introduction Application of quality control (QC) programs at diagnostic radiology departments is of great significance for optimization of image quality and reduction of patient dose. The main objective of this study was to perform QC tests on stationary radiographic X-ray machines, installed in 14 hospitals of Kerman province, Iran. Materials and Methods In this cross-sectional study, QC tests were performed on 28 conventional radiographic X-ray units in Kerman governmental hospitals, based ...

  11. Quality control of radioactive waste disposal container for borehole project

    International Nuclear Information System (INIS)

    Mohamad Pauzi Ismail; Suhairy Sani; Azhar Azmi; Ilham Mukhriz Zainal Abidin

    2014-01-01

    This paper explained quality control of radioactive disposal container for the borehole project. Non-destructive Testing (NDT) is one of the quality tool used for evaluating the product. The disposal container is made of 316L stainless steel. The suitable NDT method for this object is radiography, ultrasonic, penetrant and eddy current testing. This container will be filled with radioactive capsules and cement mortar is grouted to fill the gap. The results of NDT measurements are explained and discussed. (author)

  12. Work organisation and quality control in a welding robotic cell

    OpenAIRE

    Moniz, António

    1993-01-01

    In this paper is analyzed the work organization and the forms of quality control in a robotic welding station in a company of office equipment and metal components manufacturing. The robotic cell is recent and works in two shifts. Quality and production rationalization implied in this firms the adoption of a strategy of organization of teamwork, and it is supported the collaborative tools to decrease the possibilities for errors and to improve means and methods of manufacturing. The analysis ...

  13. Quality Assurance and Control in Laboratory using Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y. S.; Moon, J. H.; Sun, G. M.; Kim, S. H.; Baek, S. Y.; Lim, J. M.; Kim, H. R

    2007-01-15

    In accordance with the increment of international trade associated with the worldwide globalization, the importance of quality assurance and control for the commodity produced from one's own country has been stressed. ISO (International Organization for Standards) defines quality control as 'the operational techniques and activities that are used to fulfill the requirements for quality'. Since 1996, the HANARO research reactor in the Korea Atomic Energy Research Institute has been operated thereafter initial critical operation on April 1995. Neutron activation analysis system and applied techniques which is one of a nuclear analytical technologies using reactor neutrons has been developed for user's supporting and the establishment of the quality system for a measurement and analysis, testing and inspection was implemented successfully. On the basis of the qualified NAA system, the test and measurement of more than 1500 samples which is requested from 30 organizations including industrial companies, universities and institutes carried out in NAA laboratory annually. Moreover, as the goal of mutual recognition agreement (MRA) which can be removed a technical barrier in international trade, the objectivity and the confidence of analytical quality in NAA laboratory became established through the installation of international accreditation system by implementing analytical quality system in accordance with international standards in 2001. The aim of the report was to summarize the technical management of introduction, methods and the results for a quality control and assurance which should be performed in NAA technique using the HANARO research reactor. The report will help building up effective quality control strategy in the future.

  14. Crop quality control system: a tool to control the visual quality of pot plants

    NARCIS (Netherlands)

    Dijkshoorn-Dekker, M.W.C.

    2002-01-01

    Key words: quality, growth, model, leaf unfolding rate, internode, plant height, plant width, leaf area, temperature, plant spacing, season, light, development, image processing, grading, neural network, pot plant, Ficus benjamina

  15. Modern control system of quality of services of public catering

    Directory of Open Access Journals (Sweden)

    Lavrova Larisa Jur'evna

    2015-12-01

    Full Text Available The modern control system of quality of services of public catering as the instrument of management of safety is effective and legitimate. In article changes in requirements of normative documents are considered. Interdisciplinary mechanisms of implementation of requirements of normative documents are described. Uniform approaches between marketing and quality management regarding monitoring of satisfaction of consumers are determined. Results of researches of the organization of collection of information about degree of satisfaction of consumers are described. Knowledge, necessary for the staff of catering establishments, and skills regarding development, introduction and maintenance of quality management system in activity of the enterprises of food are established.

  16. Express quality control of chicken eggs by machine vision

    Science.gov (United States)

    Gorbunova, Elena V.; Chertov, Aleksandr N.; Peretyagin, Vladimir S.; Korotaev, Valery V.; Arbuzova, Evgeniia A.

    2017-06-01

    The urgency of the task of analyzing the foodstuffs quality is determined by the strategy for the formation of a healthy lifestyle and the rational nutrition of the world population. This applies to products, such as chicken eggs. In particular, it is necessary to control the chicken eggs quality at the farm production prior to incubation in order to eliminate the possible hereditary diseases, as well as high embryonic mortality and a sharp decrease in the quality of the bred young. Up to this day, in the market there are no objective instruments of contactless express quality control as analytical equipment that allow the high-precision quality examination of the chicken eggs, which is determined by the color parameters of the eggshell (color uniformity) and yolk of eggs, and by the presence in the eggshell of various defects (cracks, growths, wrinkles, dirty). All mentioned features are usually evaluated only visually (subjectively) with the help of normalized color standards and ovoscopes. Therefore, this work is devoted to the investigation of the application opportunities of contactless express control method with the help of technical vision to implement the chicken eggs' quality analysis. As a result of the studies, a prototype with the appropriate software was proposed. Experimental studies of this equipment on a representative sample of eggs from chickens of different breeds have been carried out (the total number of analyzed samples exceeds 300 pieces). The correctness of the color analysis was verified by spectrophotometric studies of the surface of the eggshell.

  17. Development and use of reference materials and quality control materials

    International Nuclear Information System (INIS)

    2003-04-01

    Current knowledge is summarized on correct use of commercially available certified reference materials (CRMs) and reference materials (RMs). Acknowledged are also the limitations and restrictions analysts have to face if they want to apply quality control. The concept of in-house RMs or quality control materials (QCMs) is advocated to supplement the use of CRMs for quality control purposes. On hand advice on how to select, prepare, characterize and use these QCMs is given from the experts' perspective. Several scenarios are described to make this concept widely applicable to: advanced laboratories with CRMs with validated analytical techniques available, laboratories with less experience and facilities, as well as cases were labile compounds and unstable matrices are involved. Each scenario considers different approaches to overcome the lack of appropriate CRMs and advise on the preparation of QCMs, which might fit the particular purpose

  18. The Quality Control of the LHC Continuous Cryostat Interconnections

    CERN Document Server

    Bertinelli, F; Bozzini, D; Cruikshank, P; Fessia, P; Grimaud, A; Kotarba, A; Maan, W; Olek, S; Poncet, A; Russenschuck, Stephan; Savary, F; Sulek, Z; Tock, J P; Tommasini, D; Vaudaux, L; Williams, L

    2008-01-01

    The interconnections between the Large Hadron Collider (LHC) magnets have required some 40 000 TIG welded joints and 65 000 electrical splices. At the level of single joints and splices, non-destructive techniques find limited application: quality control is based on the qualification of the process and of operators, on the recording of production parameters and on production samples. Visual inspection and process audits were the main techniques used. At the level of an extended chain of joints and splices - from a 53.5 m half-cell to a complete 2.7 km arc sector - quality control is based on vacuum leak tests, electrical tests and RF microwave reflectometry that progressively validated the work performed. Subsequent pressure tests, cryogenic circuits flushing with high pressure helium and cool-downs revealed a few unseen or new defects. This paper presents an overview of the quality control techniques used, seeking lessons applicable to similar large, complex projects.

  19. CT dosimetry and quality control of its operation

    International Nuclear Information System (INIS)

    Mechi, Saida

    2011-01-01

    This thesis focuses on the dosimetry of a scanner, quality control of its operations and the development of a protocol. It allowed us the mastery of the art scanner and participation in all quality controls with appropriate ghosts. CT is a radiographic examination sophisticated and accurate, widely used to screen for various diseases, among other cancer. We worked on the dosimetry of a scanner and we have made simulations with a program called Impact that calculates the CT CTDI and the PDL and compared with values displayed on the console. Similarly, the software calculates the absorbed dose and compared with that calculated by Caldose X. This work is complemented by the development of a protocol with the quality control procedures of the image and dosimetry in chronological order.

  20. Development and use of reference materials and quality control materials

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-04-01

    Current knowledge is summarized on correct use of commercially available certified reference materials (CRMs) and reference materials (RMs). Acknowledged are also the limitations and restrictions analysts have to face if they want to apply quality control. The concept of in-house RMs or quality control materials (QCMs) is advocated to supplement the use of CRMs for quality control purposes. On hand advice on how to select, prepare, characterize and use these QCMs is given from the experts' perspective. Several scenarios are described to make this concept widely applicable to: advanced laboratories with CRMs with validated analytical techniques available, laboratories with less experience and facilities, as well as cases were labile compounds and unstable matrices are involved. Each scenario considers different approaches to overcome the lack of appropriate CRMs and advise on the preparation of QCMs, which might fit the particular purpose.