WorldWideScience

Sample records for stretching force constants

  1. A novel method for the calculation of bond stretching force constants of diatomic molecules.

    Science.gov (United States)

    Kaya, Savaş; Kaya, Cemal; Obot, I B; Islam, Nazmul

    2016-02-05

    Chemical hardness is one of the chemical reactivity descriptors of chemical species and this concept has widely benefited from the development of Density Functional Theory (DFT). In the present report, chemical hardness values for approximately fifty diatomic molecules have been calculated using a new molecular hardness (η(M)) equation derived by us in recent times. Then, correlation between force constant (k) and chemical hardness for the above mentioned diatomic molecules that situate hydrides, halides, oxides and sulfides among them has been investigated. Consequently, a relation that can be presented by a simple equation between chemical hardness with bond stretching force constants has been found. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. A two force-constant model for complexes B⋯M-X (B is a Lewis base and MX is any diatomic molecule): Intermolecular stretching force constants from centrifugal distortion constants DJ or ΔJ

    Science.gov (United States)

    Bittner, Dror M.; Walker, Nicholas R.; Legon, Anthony C.

    2016-02-01

    A two force-constant model is proposed for complexes of the type B⋯MX, in which B is a simple Lewis base of at least C2v symmetry and MX is any diatomic molecule lying along a Cn axis (n ≥ 2) of B. The model assumes a rigid subunit B and that force constants beyond quadratic are negligible. It leads to expressions that allow, in principle, the determination of three quadratic force constants F11, F12, and F22 associated with the r(B⋯M) = r2 and r(M-X) = r1 internal coordinates from the equilibrium centrifugal distortion constants DJ e or ΔJ e , the equilibrium principal axis coordinates a1 and a2, and equilibrium principal moments of inertia. The model can be applied generally to complexes containing different types of intermolecular bond. For example, the intermolecular bond of B⋯MX can be a hydrogen bond if MX is a hydrogen halide, a halogen-bond if MX is a dihalogen molecule, or a stronger, coinage-metal bond if MX is a coinage metal halide. The equations were tested for BrCN, for which accurate equilibrium spectroscopic constants and a complete force field are available. In practice, equilibrium values of DJ e or ΔJ e for B⋯MX are not available and zero-point quantities must be used instead. The effect of doing so has been tested for BrCN. The zero-point centrifugal distortion constants DJ 0 or ΔJ 0 for all B⋯MX investigated so far are of insufficient accuracy to allow F11 and F22 to be determined simultaneously, even under the assumption F12 = 0 which is shown to be reasonable for BrCN. The calculation of F22 at a series of fixed values of F11 reveals, however, that in cases for which F11 is sufficiently larger than F22, a good approximation to F22 is obtained. Plots of F22 versus F11 have been provided for Kr⋯CuCl, Xe⋯CuCl, OC⋯CuCl, and C2H2⋯AgCl as examples. Even in cases where F22 ˜ F11 (e.g., OC⋯CuCl), such plots will yield either F22 or F11 if the other becomes available.

  3. A two force-constant model for complexes B⋯M-X (B is a Lewis base and MX is any diatomic molecule): Intermolecular stretching force constants from centrifugal distortion constants D(J) or Δ(J).

    Science.gov (United States)

    Bittner, Dror M; Walker, Nicholas R; Legon, Anthony C

    2016-02-21

    A two force-constant model is proposed for complexes of the type B⋯MX, in which B is a simple Lewis base of at least C2v symmetry and MX is any diatomic molecule lying along a Cn axis (n ≥ 2) of B. The model assumes a rigid subunit B and that force constants beyond quadratic are negligible. It leads to expressions that allow, in principle, the determination of three quadratic force constants F11, F12, and F22 associated with the r(B⋯M) = r2 and r(M-X) = r1 internal coordinates from the equilibrium centrifugal distortion constants DJ (e) or ΔJ (e), the equilibrium principal axis coordinates a1 and a2, and equilibrium principal moments of inertia. The model can be applied generally to complexes containing different types of intermolecular bond. For example, the intermolecular bond of B⋯MX can be a hydrogen bond if MX is a hydrogen halide, a halogen-bond if MX is a dihalogen molecule, or a stronger, coinage-metal bond if MX is a coinage metal halide. The equations were tested for BrCN, for which accurate equilibrium spectroscopic constants and a complete force field are available. In practice, equilibrium values of DJ (e) or ΔJ (e) for B⋯MX are not available and zero-point quantities must be used instead. The effect of doing so has been tested for BrCN. The zero-point centrifugal distortion constants DJ (0) or ΔJ (0) for all B⋯MX investigated so far are of insufficient accuracy to allow F11 and F22 to be determined simultaneously, even under the assumption F12 = 0 which is shown to be reasonable for BrCN. The calculation of F22 at a series of fixed values of F11 reveals, however, that in cases for which F11 is sufficiently larger than F22, a good approximation to F22 is obtained. Plots of F22 versus F11 have been provided for Kr⋯CuCl, Xe⋯CuCl, OC⋯CuCl, and C2H2⋯AgCl as examples. Even in cases where F22 ∼ F11 (e.g., OC⋯CuCl), such plots will yield either F22 or F11 if the other becomes available.

  4. Acute effects of constant torque and constant angle stretching on the muscle and tendon tissue properties.

    Science.gov (United States)

    Konrad, Andreas; Budini, Francesco; Tilp, Markus

    2017-08-01

    Static stretching induces acute structural changes of the muscle-tendon unit (MTU) that are related to the intensity or duration of stretching. It has been reported that stretching with a constant torque (CT) leads to greater joint range of motion changes than stretching with a constant angle (CA). Whether or not this difference is due to different structural changes of the MTUs of the lower leg and ankle plantar flexors is not known. Therefore, the purpose of this study was to compare the acute effects of single CA and CT stretching on various muscle and tendon mechanical properties. Seventeen young, healthy volunteers were tested on two separate days using either CT or CA stretching (4 × 30 s each). Before and after stretching, dorsiflexion range of motion (RoM), passive resistive torque (PRT), and maximum voluntary contraction (MVC) were measured with a dynamometer. Ultrasonography of the medial gastrocnemius (GM) muscle-tendon junction (MTJ) displacement allowed us to determine the length changes in the tendon and muscle, respectively, and hence to calculate their stiffness. Maximum dorsiflexion increased while PRT, muscle-tendon stiffness, and muscle stiffness decreased following both CA and CT stretching. There was a greater increase in RoM following CT stretching compared to CA stretching. Moreover, the decline in PRT was greater during CT stretching compared to CA stretching. As expected, several functional adaptations (RoM, PRT) were different between CT and CA stretching due to the higher intensity of CT stretching. However, no structural differences in the adaptations to the stretching modalities could be detected. We suggest that the different functional adaptations between CA and CT stretching are the consequence of different adaptations in the perception of stretch and pain.

  5. Constant force extensional rheometry of polymer solutions

    DEFF Research Database (Denmark)

    Szabo, Peter; McKinley, Gareth H.; Clasen, Christian

    2012-01-01

    We revisit the rapid stretching of a liquid filament under the action of a constant imposed tensile force, a problem which was first considered by Matta and Tytus [J. Non-Newton. Fluid Mech. 35 (1990) 215–229]. A liquid bridge formed from a viscous Newtonian fluid or from a dilute polymer solution...... is first established between two cylindrical disks. The upper disk is held fixed and may be connected to a force transducer while the lower cylinder falls due to gravity. By varying the mass of the falling cylinder and measuring its resulting acceleration, the viscoelastic nature of the elongating fluid...... filament can be probed. In particular, we show that with this constant force pull (CFP) technique it is possible to readily impose very large material strains and strain rates so that the maximum extensibility of the polymer molecules may be quantified. This unique characteristic of the experiment...

  6. Experimental force modeling for deformation machining stretching ...

    Indian Academy of Sciences (India)

    ARSHPREET SINGH

    magnitude of forces rises significantly. The average resul- tant force rises to 768 N for 1.0 mm incremental step size from 327 N for 0.25 mm step size, keeping other parameters constant. It can be seen that the average resultant force is directly proportional to the incremental step size and fits well with the linear trend (Eq. 5) ...

  7. Force encoding in muscle spindles during stretch of passive muscle.

    Science.gov (United States)

    Blum, Kyle P; Lamotte D'Incamps, Boris; Zytnicki, Daniel; Ting, Lena H

    2017-09-01

    Muscle spindle proprioceptive receptors play a primary role in encoding the effects of external mechanical perturbations to the body. During externally-imposed stretches of passive, i.e. electrically-quiescent, muscles, the instantaneous firing rates (IFRs) of muscle spindles are associated with characteristics of stretch such as length and velocity. However, even in passive muscle, there are history-dependent transients of muscle spindle firing that are not uniquely related to muscle length and velocity, nor reproduced by current muscle spindle models. These include acceleration-dependent initial bursts, increased dynamic response to stretch velocity if a muscle has been isometric, and rate relaxation, i.e., a decrease in tonic IFR when a muscle is held at a constant length after being stretched. We collected muscle spindle spike trains across a variety of muscle stretch kinematic conditions, including systematic changes in peak length, velocity, and acceleration. We demonstrate that muscle spindle primary afferents in passive muscle fire in direct relationship to muscle force-related variables, rather than length-related variables. Linear combinations of whole muscle-tendon force and the first time derivative of force (dF/dt) predict the entire time course of transient IFRs in muscle spindle Ia afferents during stretch (i.e., lengthening) of passive muscle, including the initial burst, the dynamic response to lengthening, and rate relaxation following lengthening. Similar to acceleration scaling found previously in postural responses to perturbations, initial burst amplitude scaled equally well to initial stretch acceleration or dF/dt, though later transients were only described by dF/dt. The transient increase in dF/dt at the onset of lengthening reflects muscle short-range stiffness due to cross-bridge dynamics. Our work demonstrates a critical role of muscle cross-bridge dynamics in history-dependent muscle spindle IFRs in passive muscle lengthening conditions

  8. Force encoding in muscle spindles during stretch of passive muscle.

    Directory of Open Access Journals (Sweden)

    Kyle P Blum

    2017-09-01

    Full Text Available Muscle spindle proprioceptive receptors play a primary role in encoding the effects of external mechanical perturbations to the body. During externally-imposed stretches of passive, i.e. electrically-quiescent, muscles, the instantaneous firing rates (IFRs of muscle spindles are associated with characteristics of stretch such as length and velocity. However, even in passive muscle, there are history-dependent transients of muscle spindle firing that are not uniquely related to muscle length and velocity, nor reproduced by current muscle spindle models. These include acceleration-dependent initial bursts, increased dynamic response to stretch velocity if a muscle has been isometric, and rate relaxation, i.e., a decrease in tonic IFR when a muscle is held at a constant length after being stretched. We collected muscle spindle spike trains across a variety of muscle stretch kinematic conditions, including systematic changes in peak length, velocity, and acceleration. We demonstrate that muscle spindle primary afferents in passive muscle fire in direct relationship to muscle force-related variables, rather than length-related variables. Linear combinations of whole muscle-tendon force and the first time derivative of force (dF/dt predict the entire time course of transient IFRs in muscle spindle Ia afferents during stretch (i.e., lengthening of passive muscle, including the initial burst, the dynamic response to lengthening, and rate relaxation following lengthening. Similar to acceleration scaling found previously in postural responses to perturbations, initial burst amplitude scaled equally well to initial stretch acceleration or dF/dt, though later transients were only described by dF/dt. The transient increase in dF/dt at the onset of lengthening reflects muscle short-range stiffness due to cross-bridge dynamics. Our work demonstrates a critical role of muscle cross-bridge dynamics in history-dependent muscle spindle IFRs in passive muscle

  9. Acute effect of constant torque and angle stretching on range of motion, muscle passive properties, and stretch discomfort perception.

    Science.gov (United States)

    Cabido, Christian E T; Bergamini, Juliana C; Andrade, André G P; Lima, Fernando V; Menzel, Hans J; Chagas, Mauro H

    2014-04-01

    The aim of the present study was to compare the acute effects of constant torque (CT) and constant angle (CA) stretching exercises on the maximum range of motion (ROMmax), passive stiffness (PS), and ROM corresponding to the first sensation of tightness in the posterior thigh (FSTROM). Twenty-three sedentary men (age, 19-33 years) went through 1 familiarization session and afterward proceeded randomly to both CA and CT treatment stretching conditions, on separate days. An isokinetic dynamometer was used to analyze hamstring muscles during passive knee extension. The subjects performed 4 stretches of 30 seconds each with a 15-second interval between them. In the CA stretching, the subject reached a certain ROM (95% of ROMmax), and the angle was kept constant. However, in the CT stretching exercise, the volunteer reached a certain resistance torque (corresponding to 95% of ROMmax) and it was kept constant. The results showed an increase in ROMmax for both CA and CT (p stretch may be explained by greater changes in the biomechanical properties of the muscle-tendon unit and stretch tolerance, as indicated by the results of PS and FSTROM.

  10. The time course of the effects of constant-angle and constant-torque stretching on the muscle-tendon unit.

    Science.gov (United States)

    Herda, T J; Costa, P B; Walter, A A; Ryan, E D; Cramer, J T

    2014-02-01

    The purpose of the present study was to examine the time course of passive range of motion (PROM), passive torque (PASTQ), and musculo-tendinous stiffness (MTS) responses during constant-angle (CA) and constant-torque (CT) stretching of the leg flexors. Eleven healthy men [mean ± standard deviation (SD): age = 21.5 ± 2.3 years] performed 16 30-s bouts of CA and CT stretching of the leg flexors. PROM, PASTQ , and MTS were measured during stretches 1, 2, 4, 8, and 16. For PROM and PASTQ , there were no differences between CA and CT stretching treatments (P > 0.05); however, there were stretch-related differences (P stretching (collapsed across CA and CT stretching) with additional increases up to 8 min of stretching. PASTQ decreased following one 30-s bout of stretching (collapsed across CA and CT stretching) and continued to decrease up to 4 min of stretching. In contrast, only the CT stretching treatment resulted in changes to MTS (P stretching, with subsequent decreases in MTS up to 6 min of stretching. These results suggested that CT stretching may be more appropriate than a stretch held at a constant muscle length for decreasing MTS. © 2012 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Acute effects of different stretching durations on passive torque, mobility, and isometric muscle force.

    Science.gov (United States)

    Matsuo, Shingo; Suzuki, Shigeyuki; Iwata, Masahiro; Banno, Yasuhiro; Asai, Yuji; Tsuchida, Wakako; Inoue, Takayuki

    2013-12-01

    Static stretching is widely applied in various disciplines. However, the acute effects of different durations of stretching are unclear. Therefore, this study was designed to investigate the acute effects of different stretching durations on muscle function and flexibility, and provide an insight into the optimal duration of static stretching. This randomized crossover trial included 24 healthy students (17 men and 7 women) who stretched their right hamstrings for durations of 20, 60, 180, and 300 seconds in a random order. The following outcomes were assessed using an isokinetic dynamometer as markers of lower-limb function and flexibility: static passive torque (SPT), dynamic passive torque (DPT), stiffness, straight leg raise (SLR), and isometric muscle force. Static passive torque was significantly decreased after all stretching durations (p stretching compared with that after 20-second stretching, and stiffness decreased significantly after 180- and 300-second stretching (p stretching (p stretching durations (p stretching than after 20-second stretching and higher after 300-second stretching than after 60-second stretching (p muscle force significantly decreased after all stretching durations (p stretching is associated with a decrease in SPT but an increase in SLR. Over 180 seconds of stretching was required to decrease DPT and stiffness, but isometric muscle force decreased regardless of the stretching duration. In conclusion, these results indicate that longer durations of stretching are needed to provide better flexibility.

  12. Longitudinal Stretching for Maturation of Vascular Tissues Using Magnetic Forces

    Directory of Open Access Journals (Sweden)

    Timothy R. Olsen

    2016-11-01

    Full Text Available Cellular spheroids were studied to determine their use as “bioinks” in the biofabrication of tissue engineered constructs. Specifically, magnetic forces were used to mediate the cyclic longitudinal stretching of tissues composed of Janus magnetic cellular spheroids (JMCSs, as part of a post-processing method for enhancing the deposition and mechanical properties of an extracellular matrix (ECM. The purpose was to accelerate the conventional tissue maturation process via novel post-processing techniques that accelerate the functional, structural, and mechanical mimicking of native tissues. The results of a forty-day study of JMCSs indicated an expression of collagen I, collagen IV, elastin, and fibronectin, which are important vascular ECM proteins. Most notably, the subsequent exposure of fused tissue sheets composed of JMCSs to magnetic forces did not hinder the production of these key proteins. Quantitative results demonstrate that cyclic longitudinal stretching of the tissue sheets mediated by these magnetic forces increased the Young’s modulus and induced collagen fiber alignment over a seven day period, when compared to statically conditioned controls. Specifically, the elastin and collagen content of these dynamically-conditioned sheets were 35- and three-fold greater, respectively, at seven days compared to the statically-conditioned controls at three days. These findings indicate the potential of using magnetic forces in tissue maturation, specifically through the cyclic longitudinal stretching of tissues.

  13. A Constant-Force Resistive Exercise Unit

    Science.gov (United States)

    Colosky, Paul; Ruttley, Tara

    2010-01-01

    A constant-force resistive exercise unit (CFREU) has been invented for use in both normal gravitational and microgravitational environments. In comparison with a typical conventional exercise machine, this CFREU weighs less and is less bulky: Whereas weight plates and associated bulky supporting structures are used to generate resistive forces in typical conventional exercise machines, they are not used in this CFREU. Instead, resistive forces are generated in this CFREU by relatively compact, lightweight mechanisms based on constant-torque springs wound on drums. Each such mechanism is contained in a module, denoted a resistive pack, that includes a shaft for making a torque connection to a cable drum. During a stroke of resistive exercise, the cable is withdrawn from the cable drum against the torque exerted by the resistance pack. The CFREU includes a housing, within which can be mounted one or more resistive pack(s). The CFREU also includes mechanisms for engaging any combination of (1) one or more resistive pack(s) and (2) one or more spring(s) within each resistive pack to obtain a desired level of resistance.

  14. Solvation free energies and solvent force constants

    International Nuclear Information System (INIS)

    Fonseca, T.; Ladanyi, B.M.; Hynes, J.T.

    1992-01-01

    A theoretical formulation for the solvent force constant k q , which gauges electrical potential fluctuations for an ion in solution and whose charge dependence is a measure of nonlinear aspects of solvation, is presented in terms of the solute charge (q) variation of the solvation free energy. This formulation allows the calculation of k q via integral equation theories. This is illustrated by a series of calculations for ionic solutes in model dipolar-quadrupolar solvents via the reference hypernetted chain (RHNC) integral equation approach. It is found that the q variation of k q can be comprehended in terms of the cooperative (or competing) contributions of the solvent dipole and quadrupole to the acceleration of the solvation free energy. By contrast, traditional notions of dielectric saturation prove to be of much less direct relevance, due in part to the importance of competing electrostriction effects. The formalism is also applied to available simulation and integral equation solvation free energy studies of aqueous ionic solvation to infer to behavior of k q . The extensions for the formalism to more complex solutes (e.g., ion pairs), to higher order fluctuations (e.g., electric field), and to the solvent frequency and effective mass are briefly indicated. 51 refs., 11 figs., 1 tab

  15. Acute Effects of Constant-Angle and Constant-Torque Static Stretching on Passive Stiffness of the Posterior Hip and Thigh Muscles in Healthy, Young and Old Men.

    Science.gov (United States)

    Palmer, Ty B

    2017-07-24

    The purpose of this study was to examine the acute effects of constant-angle (CA) and constant-torque (CT) static stretching on passive stiffness of the posterior hip and thigh muscles in healthy, young and old men. Fifteen young (25±3 years) and 15 old (71±4 years) men underwent 2 passive straight-leg raise (SLR) assessments before and after 8 min of CA and CT stretching using an isokinetic dynamometer. Passive stiffness was calculated during each SLR as the slope of the final 10% of the angle-torque curve. The results indicated that passive stiffness decreased from pre- to post-stretching for both treatments (P≤0.001-0.002) and age groups (P≤0.001-0.046); however, greater decreases were observed for the CT than the CA stretching (P=0.045) and for the old than the young men (Pstretching. These findings suggest that holding stretches at a constant tension may be a more effective strategy for altering passive stiffness of the posterior hip and thigh muscles. The greater stretch-induced stiffness decreases observed for the older men provide support that acute static stretching may be particularly effective for reducing stiffness in the elderly. As a result, it may be advantageous to prescribe static stretching prior to exercise for older adults, as this may be used to elicit substantial declines in passive stiffness, which could help reduce the risk of subsequent injury events in this population.

  16. The impact of low-frequency, low-force cyclic stretching of human bronchi on airway responsiveness.

    Science.gov (United States)

    Le Guen, Morgan; Grassin-Delyle, Stanislas; Naline, Emmanuel; Buenestado, Amparo; Brollo, Marion; Longchampt, Elisabeth; Kleinmann, Philippe; Devillier, Philippe; Faisy, Christophe

    2016-11-14

    In vivo, the airways are constantly subjected to oscillatory strain (due to tidal breathing during spontaneous respiration) and (in the event of mechanical ventilation) positive pressure. This exposure is especially problematic for the cartilage-free bronchial tree. The effects of cyclic stretching (other than high-force stretching) have not been extensively characterized. Hence, the objective of the present study was to investigate the functional and transcriptional response of human bronchi to repetitive mechanical stress caused by low-frequency, low-force cyclic stretching. After preparation and equilibration in an organ bath, human bronchial rings from 66 thoracic surgery patients were stretched in 1-min cycles of elongation and relaxation over a 60-min period. For each segment, the maximal tension corresponded to 80% of the reference contraction (the response to 3 mM acetylcholine). The impact of cyclic stretching (relative to non-stretched controls) was examined by performing functional assessments (epithelium removal and incubation with sodium channel agonists/antagonists or inhibitors of intracellular pathways), biochemical assays of the organ bath fluid (for detecting the release of pro-inflammatory cytokines), and RT-PCR assays of RNA isolated from tissue samples. The application of low-force cyclic stretching to human bronchial rings for 60 min resulted in an immediate, significant increase in bronchial basal tone, relative to non-cyclic stretching (4.24 ± 0.16 g vs. 3.28 ± 0.12 g, respectively; p human bronchi induced a myogenic response rather than activation of the pro-inflammatory signaling pathways mediated by mechanotransduction.

  17. Acute Effects of the Different Intensity of Static Stretching on Flexibility and Isometric Muscle Force.

    Science.gov (United States)

    Kataura, Satoshi; Suzuki, Shigeyuki; Matsuo, Shingo; Hatano, Genki; Iwata, Masahiro; Yokoi, Kazuaki; Tsuchida, Wakako; Banno, Yasuhiro; Asai, Yuji

    2017-12-01

    Kataura, S, Suzuki, S, Matsuo, S, Hatano, G, Iwata, M, Yokoi, K, Tsuchida, W, Banno, Y, and Asai, Y. Acute effects of the different intensity of static stretching on flexibility and isometric muscle force. J Strength Cond Res 31(12): 3403-3410, 2017-In various fields, static stretching is commonly performed to improve flexibility, whereas the acute effects of different stretch intensities are unclear. Therefore, we investigated the acute effects of different stretch intensities on flexibility and muscle force. Eighteen healthy participants (9 men and 9 women) performed 180-second static stretches of the right hamstrings at 80, 100, and 120% of maximum tolerable intensity without stretching pain, in random order. The following outcomes were assessed as markers of lower limb function and flexibility: static passive torque (SPT), range of motion (ROM), passive joint (muscle-tendon) stiffness, passive torque (PT) at onset of pain, and isometric muscle force. Static passive torque was significantly decreased after all stretching intensities (p ≤ 0.05). Compared with before stretching at 100 and 120% intensities, ROM and PT were significantly increased after stretching (p ≤ 0.05), and passive stiffness (p = 0.05) and isometric muscle force (p ≤ 0.05) were significantly decreased. In addition, ROM was significantly greater after stretching at 100 and 120% than at 80%, and passive stiffness was significantly lower after 120% than after 80% (p ≤ 0.05). However, all measurements except SPT were unchanged after 80% intensity. There was a weak positive correlation between the intensities of stretching and the relative change for SPT (p ≤ 0.05), a moderate positive correlation with ROM (p ≤ 0.05), and a moderate positive correlation with passive stiffness (p ≤ 0.05). These results indicate that static stretching at greater intensity is more effective for increasing ROM and decreasing passive muscle-tendon stiffness.

  18. Duration of static stretching influences muscle force production in hamstring muscles.

    Science.gov (United States)

    Ogura, Yuji; Miyahara, Yutetsu; Naito, Hisashi; Katamoto, Shizuo; Aoki, Junichiro

    2007-08-01

    The purpose of the present study was to investigate whether duration of static stretching could affect the maximal voluntary contraction (MVC). Volunteer male subjects (n = 10) underwent 2 different durations of static stretching of their hamstring muscles in the dominant leg: 30 and 60 seconds. No static stretching condition was used as a control condition. Before and after each stretching trial, hamstring flexibility was measured by a sit and reach test. MVC was then measured using the maximal effort of knee flexion. The hamstring flexibility was significantly increased by 30 and 60 seconds of static stretching (control: 0.5 +/- 1.1 cm; 30 seconds: 2.1 +/- 1.8 cm; 60 seconds: 3.0 +/- 1.6 cm); however, there was no significant difference between 30 and 60 seconds of static stretching conditions. The MVC was significantly lowered with 60 seconds of static stretching compared to the control and 30 seconds of the stretching conditions (control: 287.6 +/- 24.0 N; 30 seconds: 281.8 +/- 24.2 N; 60 seconds: 262.4 +/- 36.2 N). However, there was no significant difference between control and 30 seconds of static stretching conditions. Therefore, it was concluded that the short duration (30 seconds) of static stretching did not have a negative effect on the muscle force production.

  19. Does vibration counteract the static stretch-induced deficit on muscle force development?

    Science.gov (United States)

    Fernandes, Igor Alexandre; Kawchuk, Gregory; Bhambhani, Yagesh; Gomes, Paulo Sergio Chagas

    2013-09-01

    To determine the residual acute vibration-stretching effect on preactivation levels, short-latency stretch reflex, and performance during execution of drop jumps. Repeated measures. Eleven male recreational athletes performed a set of three 45cm drop jumps before and immediately after a 30s static stretching exercise with and without simultaneously imposed muscle vibration (45Hz, 5mm). Drop jump height, ground reaction forces and electromyographic data including Vastus Lateralis onset/levels of preactivation and short-latency stretch reflex were recorded. No changes were induced on drop jump height. However, stretching-induced decrements on ground reaction force peak and time to peak as well as an increment in contact time followed a delay in short-latency stretch reflex onset and a reduced preactivation level of Vastus Lateralis. Otherwise, when vibration was simultaneously imposed, there was no evidence of changes in high-speed force production variables or electromyographic recordings. Mechanical vibration, when applied simultaneously to static-stretching routines, appeared to be effective to counteract decreased musculotendinous unit stiffness-induced high-speed force production deficit during jumping performance. Copyright © 2012. Published by Elsevier Ltd.

  20. Identification of force constants in β-brass

    DEFF Research Database (Denmark)

    Norvell, J. C.; Als-Nielsen, Jens Aage

    1969-01-01

    The phonon dispersion curves of β-brass have previously been measured by Gilat and Dolling and a fit was obtained to a Born-von Kármán model with forces extending to the fourth nearest neighbours. Although a factor of 10 was found between the second-nearest-neighbour Cu-Cu and Zn-Zn force constants......, the data did not allow an identification of these constants. By comparisons of neutron group intensities from two β-brass crystals, one with normal Cu and the other isotopically enriched with 65Cu, we are able to identify conclusively these force constants: αZn-Zn2nd similar, equals 10αCu-Cu2nd....

  1. Titin force enhancement following active stretch of skinned skeletal muscle fibres.

    Science.gov (United States)

    Powers, Krysta; Joumaa, Venus; Jinha, Azim; Moo, Eng Kuan; Smith, Ian Curtis; Nishikawa, Kiisa; Herzog, Walter

    2017-09-01

    In actively stretched skeletal muscle sarcomeres, titin-based force is enhanced, increasing the stiffness of active sarcomeres. Titin force enhancement in sarcomeres is vastly reduced in mdm , a genetic mutation with a deletion in titin. Whether loss of titin force enhancement is associated with compensatory mechanisms at higher structural levels of organization, such as single fibres or entire muscles, is unclear. The aim of this study was to determine whether mechanical deficiencies in titin force enhancement are also observed at the fibre level, and whether mechanisms compensate for the loss of titin force enhancement. Single skinned fibres from control and mutant mice were stretched actively and passively beyond filament overlap to observe titin-based force. Mutant fibres generated lower contractile stress (force divided by cross-sectional area) than control fibres. Titin force enhancement was observed in control fibres stretched beyond filament overlap, but was overshadowed in mutant fibres by an abundance of collagen and high variability in mechanics. However, titin force enhancement could be measured in all control fibres and most mutant fibres following short stretches, accounting for ∼25% of the total stress following active stretch. Our results show that the partial loss of titin force enhancement in myofibrils is not preserved in all mutant fibres and this mutation likely affects fibres differentially within a muscle. An increase in collagen helps to reestablish total force at long sarcomere lengths with the loss in titin force enhancement in some mutant fibres, increasing the overall strength of mutant fibres. © 2017. Published by The Company of Biologists Ltd.

  2. Upper body force production after a low-volume static and dynamic stretching.

    Science.gov (United States)

    Leone, D C P G; Pezarat, P; Valamatos, M J; Fernandes, O; Freitas, S; Moraes, A C

    2014-01-01

    This study investigated the acute effect of a low-volume static and dynamic stretching on maximal isometric peak force (MIPF), time to maximal isometric force (TMIF), rate of force production (RFP) and average amplitude of the surface EMG (AvgEMG) of the main agonist muscles acting on the bench press maximum isometric force exercise. Thirty subjects were randomly divided into three groups: static stretch (SG: 22.8 ± 5.6 years, 176.6 ± 3.5 cm, 74.4 ± 5.9 kg), dynamic stretch (DG: 21.4 ± 3.9 years, 178.4 ± 7.2 cm, 71.7 ± 8.2 kg) and control group (CG: 20.4 ± 3.6 years, 179.8 ± 5.8 cm, 74.4 ± 9.8 kg). SG performed two 30-s repetitions and DG performed 10 repetitions of each of the two different exercises for the pectoralis major and triceps brachii. The MIPF, TMIF, RFP and AvgEMG of the pectoralis major (sternocostal part) and triceps brachii (long and lateral head) were measured before and immediately after the stretching protocols. A significant decrease in the MIPF from pre- to post-stretching was observed in both SG (p force parameters. No significant differences in the TMIF and RFP from pre- to post-stretching were found in the three groups. The SG showed a significant (p static and dynamic stretching adversely affects efforts of muscle maximal strength of the upper limb muscles studied, but it does not seem to affect TMIF or RFP.

  3. Force produced after stretch in sarcomeres and half-sarcomeres isolated from skeletal muscles

    Science.gov (United States)

    Minozzo, Fábio C.; Baroni, Bruno M.; Correa, José A.; Vaz, Marco A.; Rassier, Dilson E.

    2013-07-01

    The goal of this study was to evaluate if isolated sarcomeres and half-sarcomeres produce a long-lasting increase in force after a stretch is imposed during activation. Single and half-sarcomeres were isolated from myofibrils using micro-needles, which were also used for force measurements. After full force development, both preparations were stretched by different magnitudes. The sarcomere length (SL) or half-sarcomere length variations (HSL) were extracted by measuring the initial and final distances from the Z-line to the adjacent Z-line or to a region externally adjacent to the M-line of the sarcomere, respectively. Half-sarcomeres generated approximately the same amount of isometric force (29.0 +/- SD 15.5 nN.μm-2) as single sarcomeres (32.1 +/- SD 15.3 nN.μm-2) when activated. In both cases, the steady-state forces after stretch were higher than the forces during isometric contractions at similar conditions. The results suggest that stretch-induced force enhancement is partly caused by proteins within the half-sarcomere.

  4. Lack of effect of moderate-duration static stretching on plantar flexor force production and series compliance.

    Science.gov (United States)

    Cannavan, Dale; Coleman, David R; Blazevich, Anthony J

    2012-03-01

    The effects of an acute bout of moderate-duration static stretching on plantar flexor force production, series compliance of the muscle-tendon unit, and levels of neuromuscular activation were examined. Eighteen active individuals (9 men and 9 women) performed four 45-s static plantar flexor stretches and a time-matched control of no stretch (where subjects remained seated in the dynamometer for 4 min with no stretch being performed). Measures of peak isometric moment, rate of force development, neuromuscular activation (interpolated twitch technique and electromyography), twitch force characteristics, passive moment during stretch, and tendon elongation during maximal voluntary contractions were taken before and after the stretching. Despite a significant stress-relaxation response during stretch (9.3%, Pforce development (P=0.93; effect size 0.01), neuromuscular activation (interpolated twitch: P=0.86; electromyography: P=0.09; effect size 0.02), or tendon elongation (P=0.61; effect size 0.07) after stretching. Twitch characteristics were also unchanged after stretching, although there was a reduction in the rate of twitch torque relaxation (RR(t); Pstatic stretching did not impair the force generating capacity of the plantar flexors or negatively affect muscle-tendon mechanical properties. Static stretching may not always have detrimental consequences for force production. Thus, clinicians may be able to apply moderate-duration stretches to patients without risk of reducing muscular performance. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. The effects of stretching exercise for upper trapezius on the asymmetric rate of bite force.

    Science.gov (United States)

    Lee, Bomjin; Lee, Joongsook; Yang, Jeongok; Heo, Kwangjin; Hwang, Hojin; Kim, Boyoung; Han, Dongwook

    2015-07-01

    [Purpose] The purpose of this study was to observe the effects of stretching the upper trapezius muscle on the asymmetric rate of bite force. [Subjects] Forty-seven female university students who had all their original teeth, had no disorders in the temporomandibular joints, and had never worn braces; participated in this study. [Methods] An occlusometer was used to measure biting forces. Subsequently, stretching exercises of the upper trapezius were performed. The subjects were divided into 3 groups at the start of the testing: the asymmetric rate of the first group was less than 10%; the asymmetric rate of the second group was between 10% and 20%; and the asymmetric rate of the third group was more than 20%. The stretching exercises were done on the dominant side of the upper trapezius. [Results] After the stretching exercises of the upper trapezius, the results showed that for the first group, whose asymmetric rate of biting force was less than 10%, there was a significant increase in asymmetric rate (from 5.1% to 10.3%). For the second group, whose asymmetric rate of biting force was measured to be between 10% and 20%, the asymmetric rate decreased from 14.7% to 14.3%, but the change was not statistically significant. For the third group, whose asymmetric rate of biting force was more than 20%, there was a significant decrease in asymmetric rate (from 27.8% to 12.6%). [Conclusion] We concluded that stretching exercises of the upper trapezius muscle had a direct effect on the asymmetric rate of biting force.

  6. Intermittent flow under constant forcing: Acoustic emission from creep avalanches

    Science.gov (United States)

    Salje, Ekhard K. H.; Liu, Hanlong; Jin, Linsen; Jiang, Deyi; Xiao, Yang; Jiang, Xiang

    2018-01-01

    While avalanches in field driven ferroic systems (e.g., Barkhausen noise), domain switching of martensitic nanostructures, and the collapse of porous materials are well documented, creep avalanches (avalanches under constant forcing) were never observed. Collapse avalanches generate particularly large acoustic emission (AE) signals and were hence chosen to investigate crackling noise under creep conditions. Piezoelectric SiO2 has a strong piezoelectric response even at the nanoscale so that we chose weakly bound SiO2 spheres in natural sandstone as a representative for the study of avalanches under time-independent, constant force. We found highly non-stationary crackling noise with four activity periods, each with power law distributed AE emission. Only the period before the final collapse shows the mean field behavior (ɛ near 1.39), in agreement with previous dynamic measurements at a constant stress rate. All earlier event periods show collapse with larger exponents (ɛ = 1.65). The waiting time exponents are classic with τ near 2.2 and 1.32. Creep data generate power law mixing with "effective" exponents for the full dataset with combinations of mean field and non-mean field regimes. We find close agreement with the predicted time-dependent fiber bound simulations, including events and waiting time distributions. Båth's law holds under creep conditions.

  7. Gravity-independent constant force resistive exercise unit

    Science.gov (United States)

    Colosky, Jr., Paul E. (Inventor); Ruttley, Tara M. (Inventor)

    2004-01-01

    This invention describes a novel gravity-independent exercise unit designed for use in microgravity, or on the ground, as a means by which to counter muscle atrophy and bone degradation due to disuse or underuse. Modular resistive packs comprising constant torque springs provide constant force opposing the withdrawal of an exercise cable from the device. In addition to uses within the space program, the compact resistive packs of the CFREU allow the unit to be small enough for easy use as a home gym for personal use, or as a supplement for rehabilitation programs. Resistive packs may be changed conveniently out of the CFREU according to the desired exercise regimen. Thus, the resistive packs replace the need for expensive, heavy, and bulky traditional weight plates. The CFREU may be employed by hospitals, rehabilitation and physical therapy clinics, and other related professional businesses.

  8. Acute effect of static stretching on muscle force in older women

    Directory of Open Access Journals (Sweden)

    André Luiz Demantova Gurjão

    2010-04-01

    Full Text Available The objective of this study was to investigate the acute effect of static stretching on the peak rate of force development (PRFD and maximum voluntary contraction (MVC in older women. Ten women (68.5 ± 7.0 years; 70.9 ± 8.1 kg; 159.4 ± 6.0 cm; body mass index: 28.0 ± 3.8 kg/m2 were studied. MVC and PRFD were determined by leg press exercise before and after the control or stretching condition (three sets of 30 seconds of static stretching of the quadriceps on two different days (interval of 24 hours. PRFD was determined as the steepest slope of the curve, calculated within regular windows of 20 milliseconds (∆force/∆time for the first 200 milliseconds after the onset of contraction. MVC was determined as the highest value recorded in each set. Only one condition was tested on each day and the order of application of each condition was determined randomly. The stretching intensity was evaluated by the muscle pain threshold. Four post-condition assessments (post-treatment, 10, 20, and 30 minutes were performed to monitor muscle strength. ANCOVA 2x5, followed by the Scheffé post-hoc test, showed no significant interactions between conditions vs. times (P > 0.05 for PRFD or MVC. In conclusion, acute bouts of static stretching of the quadriceps femoris do not affect the ability of rapid and maximum muscle force production in older women.

  9. The Effect of Static Stretching in Agility and Isokinetic Force at Football Players

    Directory of Open Access Journals (Sweden)

    Sami Sermaxhaj

    2017-10-01

    Full Text Available Cool Down is very important for the recuperation of a football player. The objective of this research is to prove the effect of recuperation with static stretching in agility and isokinetic force at the young football players. This research has taken place between August and November 2015 with a sample of 24 football players of age 15.6±0.4 years, divided in the control group and the experimental group. At first measurements have been initialed body weight 61.1±0.4 kg and body height 175.7±6.4 cm, and agility (20 m zig-zag with and without ball and isokinetic force (peak torque flexion and extension. Both groups of the football players have completed the regular training program. The experimental group (despite the control group during the stage of recuperation (cool down, except the running with slow pace did also carry out the experimental program which did take place through static stretching. Experimental program consisted of 17 exercises bodily static stretching which are applied in the final training session (cool-down. After the experimental phase is finished the participants did undergo the final measures. The conducted results with univariate analysis of variance (ANOVA in two tests (initial and final have shown unimportant statistical values between the control group and the experimental one in the isokinetic force and agility. From the collected results we can conclude the recuperation with static stretching during the cool down has an unimportant statistical impact in the agility and isokinetic force of the young football players.

  10. Stretch force guides finger-like pattern of bone formation in suture.

    Science.gov (United States)

    Wu, Bo-Hai; Kou, Xiao-Xing; Zhang, Ci; Zhang, Yi-Mei; Cui, Zhen; Wang, Xue-Dong; Liu, Yan; Liu, Da-Wei; Zhou, Yan-Heng

    2017-01-01

    Mechanical tension is widely applied on the suture to modulate the growth of craniofacial bones. Deeply understanding the features of bone formation in expanding sutures could help us to improve the outcomes of clinical treatment and avoid some side effects. Although there are reports that have uncovered some biological characteristics, the regular pattern of sutural bone formation in response to expansion forces is still unknown. Our study was to investigate the shape, arrangement and orientation of new bone formation in expanding sutures and explore related clinical implications. The premaxillary sutures of rat, which histologically resembles the sutures of human beings, became wider progressively under stretch force. Micro-CT detected new bones at day 3. Morphologically, these bones were forming in a finger-like pattern, projecting from the maxillae into the expanded sutures. There were about 4 finger-like bones appearing on the selected micro-CT sections at day 3 and this number increased to about 18 at day 7. The average length of these projections increased from 0.14 mm at day 3 to 0.81 mm at day 7. The volume of these bony protuberances increased to the highest level of 0.12 mm3 at day 7. HE staining demonstrated that these finger-like bones had thick bases connecting with the maxillae and thin fronts stretching into the expanded suture. Nasal sections had a higher frequency of finger-like bones occuring than the oral sections at day 3 and day 5. Masson-stained sections showed stretched fibers embedding into maxillary margins. Osteocalcin-positive osteoblasts changed their shapes from cuboidal to spindle and covered the surfaces of finger-like bones continuously. Alizarin red S and calcein deposited in the inner and outer layers of finger-like bones respectively, which showed that longer and larger bones formed on the nasal side of expanded sutures compared with the oral side. Interestingly, these finger-like bones were almost paralleling with the direction

  11. Determination of the attractive force, adhesive force, adhesion energy and Hamaker constant of soot particles generated from a premixed methane/oxygen flame by AFM

    Science.gov (United States)

    Liu, Ye; Song, Chonglin; Lv, Gang; Chen, Nan; Zhou, Hua; Jing, Xiaojun

    2018-03-01

    Atomic force microscopy (AFM) was used to characterize the attractive force, adhesive force and adhesion energy between an AFM probe tip and nanometric soot particle generated by a premixed methane/oxygen flame. Different attractive force distributions were found when increasing the height above burner (HAB), with forces ranging from 1.1-3.5 nN. As the HAB was increased, the average attractive force initially increased, briefly decreased, and then underwent a gradual increase, with a maximum of 2.54 nN observed at HAB = 25 mm. The mean adhesive force was 6.5-7.5 times greater than the mean attractive force at the same HAB, and values were in the range of 13.5-24.5 nN. The adhesion energy was in the range of 2.0-5.6 × 10-17 J. The variations observed in the average adhesion energy with increasing HAB were different from those of the average adhesion force, implying that the stretched length of soot particles is an important factor affecting the average adhesion energy. The Hamaker constants of the soot particles generated at different HABs were determined from AFM force-separation curves. The average Hamaker constant exhibited a clear correlation with the graphitization degree of soot particles as obtained from Raman spectroscopy.

  12. Mesoscopic models for DNA stretching under force: New results and comparison with experiments.

    Science.gov (United States)

    Manghi, Manoel; Destainville, Nicolas; Palmeri, John

    2012-10-01

    Single-molecule experiments on double-stranded B-DNA stretching have revealed one or two structural transitions, when increasing the external force. They are characterized by a sudden increase of DNA contour length and a decrease of the bending rigidity. The nature and the critical forces of these transitions depend on DNA base sequence, loading rate, salt conditions and temperature. It has been proposed that the first transition, at forces of 60-80 pN, is a transition from B to S-DNA, viewed as a stretched duplex DNA, while the second one, at stronger forces, is a strand peeling resulting in single-stranded DNAs (ssDNA), similar to thermal denaturation. But due to experimental conditions these two transitions can overlap, for instance for poly(dA-dT). In an attempt to propose a coherent picture compatible with this variety of experimental observations, we derive an analytical formula using a coupled discrete worm-like chain-Ising model. Our model takes into account bending rigidity, discreteness of the chain, linear and non-linear (for ssDNA) bond stretching. In the limit of zero force, this model simplifies into a coupled model already developed by us for studying thermal DNA melting, establishing a connection with previous fitting parameter values for denaturation profiles. Our results are summarized as follows: i) ssDNA is fitted, using an analytical formula, over a nano-Newton range with only three free parameters, the contour length, the bending modulus and the monomer size; ii) a surprisingly good fit on this force range is possible only by choosing a monomer size of 0.2 nm, almost 4 times smaller than the ssDNA nucleobase length; iii) mesoscopic models are not able to fit B to ssDNA (or S to ss) transitions; iv) an analytical formula for fitting B to S transitions is derived in the strong force approximation and for long DNAs, which is in excellent agreement with exact transfer matrix calculations; v) this formula fits perfectly well poly(dG-dC) and

  13. The Effect of Static Stretching in Agility and Isokinetic Force at Football Players

    OpenAIRE

    Sami Sermaxhaj; Fitim Arifi; Abedin Bahtiri

    2017-01-01

    Cool Down is very important for the recuperation of a football player. The objective of this research is to prove the effect of recuperation with static stretching in agility and isokinetic force at the young football players. This research has taken place between August and November 2015 with a sample of 24 football players of age 15.6±0.4 years, divided in the control group and the experimental group. At first measurements have been initialed body weight 61.1±0.4 kg and body height 175.7±6....

  14. The acute effects of static stretching on peak force, peak rate of force development and muscle activity during single- and multiple-joint actions in older women.

    Science.gov (United States)

    Gonçalves, Raquel; Gurjão, André Luiz Demantova; Jambassi Filho, José Claudio; Farinatti, Paulo De Tarso Veras; Gobbi, Lilian Teresa Bucken; Gobbi, Sebastião

    2013-01-01

    The present study investigated the acute effects of static stretching on peak force, peak rate of force development and integrated electromyography (iEMG) in 27 older women (65 ± 4 years; 69 ± 9 kg; 157 ± 1 cm; 28 ± 4 kg · m(-2)). The participants were tested during two exercises (leg press and knee extension) after two conditions: stretching and control. The data were collected on four days (counterbalanced with a 24-hour rest period). In the stretching condition, the quadriceps muscle was stretched (knee flexion) for three sets of 30 s with 30 s rest intervals. No significant difference was detected for peak force and peak rate of force development during the single- and multiple-joint exercises, regardless of the following interactions: condition (stretching and control) vs. time (pre x post x 10 x 20 x 30 minutes post; P > 0.05) and exercise vs. time (P > 0.05). Additionally, no significant interaction was found for the iEMG activity (condition vs. time; P > 0.05) in the single- and multiple-joint exercises. In conclusion, a small amount of stretching of an agonist muscle (quadriceps) did not affect the peak force, peak rate of force development and EMG activity in older women during single- and multiple-joint exercises.

  15. The Comfortable Roller Coaster--on the Shape of Tracks with a Constant Normal Force

    Science.gov (United States)

    Nordmark, Arne B.; Essen, Hanno

    2010-01-01

    A particle that moves along a smooth track in a vertical plane is influenced by two forces: gravity and normal force. The force experienced by roller coaster riders is the normal force, so a natural question to ask is, what shape of the track gives a normal force of constant magnitude? Here we solve this problem. It turns out that the solution is…

  16. Forced convective heat transfer in boundary layer flow of Sisko fluid over a nonlinear stretching sheet.

    Science.gov (United States)

    Munir, Asif; Shahzad, Azeem; Khan, Masood

    2014-01-01

    The major focus of this article is to analyze the forced convective heat transfer in a steady boundary layer flow of Sisko fluid over a nonlinear stretching sheet. Two cases are studied, namely (i) the sheet with variable temperature (PST case) and (ii) the sheet with variable heat flux (PHF case). The heat transfer aspects are investigated for both integer and non-integer values of the power-law index. The governing partial differential equations are reduced to a system of nonlinear ordinary differential equations using appropriate similarity variables and solved numerically. The numerical results are obtained by the shooting method using adaptive Runge Kutta method with Broyden's method in the domain[Formula: see text]. The numerical results for the temperature field are found to be strongly dependent upon the power-law index, stretching parameter, wall temperature parameter, material parameter of the Sisko fluid and Prandtl number. In addition, the local Nusselt number versus wall temperature parameter is also graphed and tabulated for different values of pertaining parameters. Further, numerical results are validated by comparison with exact solutions as well as previously published results in the literature.

  17. Forced convective heat transfer in boundary layer flow of Sisko fluid over a nonlinear stretching sheet.

    Directory of Open Access Journals (Sweden)

    Asif Munir

    Full Text Available The major focus of this article is to analyze the forced convective heat transfer in a steady boundary layer flow of Sisko fluid over a nonlinear stretching sheet. Two cases are studied, namely (i the sheet with variable temperature (PST case and (ii the sheet with variable heat flux (PHF case. The heat transfer aspects are investigated for both integer and non-integer values of the power-law index. The governing partial differential equations are reduced to a system of nonlinear ordinary differential equations using appropriate similarity variables and solved numerically. The numerical results are obtained by the shooting method using adaptive Runge Kutta method with Broyden's method in the domain[Formula: see text]. The numerical results for the temperature field are found to be strongly dependent upon the power-law index, stretching parameter, wall temperature parameter, material parameter of the Sisko fluid and Prandtl number. In addition, the local Nusselt number versus wall temperature parameter is also graphed and tabulated for different values of pertaining parameters. Further, numerical results are validated by comparison with exact solutions as well as previously published results in the literature.

  18. Forced convection boundary layer MHD flow of nanofluid over a permeable stretching plate with viscous dissipation

    Directory of Open Access Journals (Sweden)

    Habibi Matin Meisam

    2014-01-01

    Full Text Available Forced convection boundary layer magneto-hydrodynamic (MHD flow of a nanofluid over a permeable stretching plate is studied in this paper. The effects of suction-injection and viscous dissi1pation are taken into account. The nanofluid model includes Brownian motion and thermophoresis effects. The governing momentum, energy and nanofluid solid volume fraction equations are solved numerically using an implicit finite difference scheme known as Keller-box method and the results are compared with available numerical data. The results for the dimensionless velocity, dimensionless temperature, dimensionless nanofluid solid volume fraction, reduced Nusselt and reduced Sherwood numbers are presented illustrating the effects of magnetic parameter, suction-injection parameter, Brownian motion parameter, thermophoresis parameter, Prandtl number, Eckert number and Lewis number.

  19. Evaluation of the effect of different stretching patterns on force decay and tensile properties of elastomeric ligatures.

    Science.gov (United States)

    Aminian, Amin; Nakhaei, Samaneh; Agahi, Raha Habib; Rezaeizade, Masoud; Aliabadi, Hamed Mirzazadeh; Heidarpour, Majid

    2015-01-01

    There have been numerous researches on elastomeric ligatures, but clinical conditions in different stages of treatment are not exactly similar to laboratory conditions. The aim of this in vitro study was to simulate clinical conditions and evaluate the effect of three stretching patterns on the amount of force, tensile strength (TS) and extension to TS of the elastomers during 8 weeks. Forces, TS and extension to TS of two different brands of elastomers were measured at initial, 24 h and 2, 4, and 8-week intervals using a testing machine. During the study period, the elastomers were stored in three different types of jig (uniform stretching, 1 and 3 mm point stretching) designed by the computer-aided design and computer-aided manufacturing technique in order to simulate the different stages of orthodontic treatment. The elastomeric ligatures under study exhibited a similar force decay pattern. The maximum force decay occurred during the first 24 h (49.9% ± 15%) and the amount of force decay was 75.7% ± 8% after 8 weeks. In general, the TS decreased during the study period, and the amount of extension to TS increased. Although the elastic behavior of all ligatures under study was similar, the amount of residual force, TS and extension to TS increased in elastomers under point stretching pattern.

  20. Effects of proprioceptive neuromuscular facilitation stretching on stiffness and force-producing characteristics of the ankle in active women.

    Science.gov (United States)

    Rees, Sven S; Murphy, Aron J; Watsford, Mark L; McLachlan, Ken A; Coutts, Aaron J

    2007-05-01

    The purpose of this study was to examine the effect of proprioceptive neuromuscular facilitation (PNF) stretching on musculotendinous unit (MTU) stiffness of the ankle joint. Twenty active women were assessed for maximal ankle range of motion, maximal strength of planter flexors, rate of force development, and ankle MTU stiffness. Subjects were randomly allocated into an experimental (n = 10) group or control group (n = 10). The experimental group performed PNF stretching on the ankle joint 3 times per week for 4 weeks, with physiological testing performed before and after the training period. After training, the experimental group significantly increased ankle range of motion (7.8%), maximal isometric strength (26%), rate of force development (25%), and MTU stiffness (8.4%) (p < 0.001). Four weeks of PNF stretching contributed to an increase in MTU stiffness, which occurred concurrently with gains to ankle joint range of motion. The results confirm that MTU stiffness and joint range of motion measurements appear to be separate entities. The increased MTU stiffness after the training period is explained by adaptations to maximal isometric muscle contractions, which were a component of PNF stretching. Because a stiffer MTU system is linked with an improved the ability to store and release elastic energy, PNF stretching would benefit certain athletic performance due to a reduced contraction time or greater mechanical efficiency. The results of this study suggest PNF stretching is a useful modality at increasing a joint's range of motion and its strength.

  1. Potential role of strain hardening in the cessation of rifting at constant tectonic force

    NARCIS (Netherlands)

    Yamasaki, T.; Stephenson, R.A.

    2009-01-01

    In this study the cessation of rifting at constant tectonic force is discussed from the viewpoint of lithospheric rheology using a simple one-dimensional numerical model. The behaviour of the conventionally adopted constant force model re-examined in this study contradicts some general features in

  2. Factors of force potentiation induced by stretch-shortening cycle in plantarflexors.

    Directory of Open Access Journals (Sweden)

    Atsuki Fukutani

    Full Text Available Muscle force is potentiated by countermovement; this phenomenon is called stretch-shortening cycle (SSC effect. In this study, we examined the factors strongly related to SSC effect in vivo, focusing on tendon elongation, preactivation, and residual force enhancement. Twelve healthy men participated in this study. Ankle joint angle was passively moved by a dynamometer, with a range of motion from 15° dorsiflexion (DF to 15° plantarflexion (PF. Muscle contraction was evoked by electrical stimulation, with stimulation timing adjusted to elicit three types of contraction: (1 concentric contraction without preliminary contraction (CON, (2 concentric contraction after preliminary eccentric contraction (ECC, and (3 concentric contraction after preliminary isometric contraction (ISO. Joint torque was recorded at DF5°, PF0°, and PF5°, respectively. SSC effect was calculated as the ratio of joint torque obtained in ECC or ISO with respect to that obtained in CON at the aforementioned three joint angles. SSC effect was prominent in the first half of movement in both ECC (DF5°, 329.3 ± 101.2%; PF0°, 159.2 ± 29.4%; PF5°, 125.5 ± 20.8% and ISO (DF5°, 276.4 ± 87.0%; PF0°, 134.5 ± 24.5%; PF5°, 106.8 ± 18.0% conditions. SSC effect was significantly larger in ECC than in ISO at all joint angles (P < 0.001. Even without preliminary eccentric contraction (i.e., ISO condition, SSC effect was clearly large, indicating that a significant part of SSC effect is derived from preactivation. However, the active lengthening-induced force potentiation mechanism (residual force enhancement also contributes to SSC effect.

  3. How strong is it? The interpretation of force and compliance constants as bond strength descriptors.

    Science.gov (United States)

    Brandhorst, Kai; Grunenberg, Jörg

    2008-08-01

    Knowledge about individual covalent or non-covalent bond strengths is the Holy Grail of many modern molecular sciences. Recent developments of new descriptors for such interaction strengths based on potential constants are summarised in this tutorial review. Several publications for and against the use of compliance matrices (inverse force constants matrix) have appeared in the literature in the last few years. However the mathematical basis for understanding, and therefore interpreting, compliance constants is still not well developed. We therefore summarise the theoretical foundations and point to the advantages and disadvantages of the use of force constants versus compliance constants for the description of both non-covalent and covalent interactions.

  4. Reliability and consistency of plantarflexor stretch-shortening cycle function using an adapted force sledge apparatus

    International Nuclear Information System (INIS)

    Furlong, Laura-Anne M; Harrison, Andrew J

    2013-01-01

    There are various limitations to existing methods of studying plantarflexor stretch-shortening cycle (SSC) function and muscle-tendon unit (MTU) mechanics, predominantly related to measurement validity and reliability. This study utilizes an innovative adaptation to a force sledge which isolates the plantarflexors and ankle for analysis. The aim of this study was to determine the sledge loading protocol to be used, most appropriate method of data analysis and measurement reliability in a group of healthy, non-injured subjects. Twenty subjects (11 males, 9 females; age: 23.5 ±2.3 years; height: 1.73 ±0.08 m; mass: 74.2 ±11.3 kg) completed 11 impacts at five different loadings rated on a scale of perceived exertion from 1 to 5, where 5 is a loading that the subject could only complete the 11 impacts using the adapted sledge. Analysis of impacts 4–8 or 5–7 using loading 2 provided consistent results that were highly reliable (single intra-class correlation, ICC > 0.85, average ICC > 0.95) and replicated kinematics found in hopping and running. Results support use of an adapted force sledge apparatus as an ecologically valid, reliable method of investigating plantarflexor SSC function and MTU mechanics in a dynamic controlled environment. (paper)

  5. The rate of force development obtained at early contraction phase is not influenced by active static stretching.

    Science.gov (United States)

    Morais de Oliveira, André L; Greco, Camila Coelho; Molina, Renato; Denadai, Benedito S

    2012-08-01

    The objective of this study was to investigate the influence of active static stretching on the maximal isometric muscle strength (maximal voluntary contraction [MVC]) and rate of force development (RFD) determined within time intervals of 30, 50, 100, and 200 milliseconds relative to the onset of muscle contraction. Fifteen men (aged 21.3 ± 2.4 years) were submitted on different days to the following tests: (a) familiarization session to the isokinetic dynamometer; (b) 2 maximal isometric contractions for knee extensors in the isokinetic dynamometer to determine MVC and RFD (control); and (c) 2 active static stretching exercises for the dominant leg extensors (10 × 30 seconds for each exercise with a 20-second rest interval between bouts). After stretching, the isokinetic test was repeated (poststretching). Conditions 2 and 3 were performed in random order. The RFD was considered as the mean slope of the moment-time curve at time intervals of 0-30, 0-50, 0-100; 0-150; and 0200 milliseconds relative to the onset of muscle contraction. The MVC was reduced after stretching (285 ± 59 vs. 271 ± 56 N · m, p 0.05). However, the RFD measured at intervals of 0-150 and 0-200 milliseconds was significantly lower after stretching (p static stretching when compared with actions using maximal muscle strength.

  6. Corruption and economic growth with non constant labor force growth

    Science.gov (United States)

    Brianzoni, Serena; Campisi, Giovanni; Russo, Alberto

    2018-05-01

    Based on Brianzoni et al. [1] in the present work we propose an economic model regarding the relationship between corruption in public procurement and economic growth. We extend the benchmark model by introducing endogenous labor force growth, described by the logistic equation. The results of previous studies, as Del Monte and Papagni [2] and Mauro [3], show that countries are stuck in one of the two equilibria (high corruption and low economic growth or low corruption and high economic growth). Brianzoni et al. [1] prove the existence of a further steady state characterized by intermediate levels of capital per capita and corruption. Our aim is to investigate the effects of the endogenous growth around such equilibrium. Moreover, due to the high number of parameters of the model, specific attention is given to the numerical simulations which highlight new policy measures that can be adopted by the government to fight corruption.

  7. Duration Dependent Effect of Static Stretching on Quadriceps and Hamstring Muscle Force

    Directory of Open Access Journals (Sweden)

    Leyla Alizadeh Ebadi

    2018-03-01

    Full Text Available The aim of this study was to determine the acute effect of static stretching on hamstring and quadriceps muscles’ isokinetic strength when applied for various durations to elite athletes, to investigate the effect of different static stretching durations on isokinetic strength, and finally to determine the optimal stretching duration. Fifteen elite male athletes from two different sport branches (10 football and five basketball participated in this study. Experimental protocol was designed as 17 repetitive static stretching exercises for hamstring and quadriceps muscle groups according to the indicated experimental protocols; ((A 5 min jogging; (B 5 min jogging followed by 15 s static stretching; (C 5 min jogging followed by 30 s static stretching; (D 5 min jogging, followed by static stretching for 45 s. Immediately after each protocol, an isokinetic strength test consisting of five repetitions at 60°/s speed and 20 repetitions at 180°/s speed was recorded for the right leg by the Isomed 2000 device. Friedman variance analysis test was employed for data analysis. According to the analyzes, it was observed that 5 min jogging and 15 s stretching exercises increased the isokinetic strength, whereas 30 and 45 s stretching exercises caused a decrease.

  8. Protonated Nitrous Oxide, NNOH(+): Fundamental Vibrational Frequencies and Spectroscopic Constants from Quartic Force Fields

    Science.gov (United States)

    Huang, Xinchuan; Fortenberry, Ryan C.; Lee, Timothy J.

    2013-01-01

    The interstellar presence of protonated nitrous oxide has been suspected for some time. Using established high-accuracy quantum chemical techniques, spectroscopic constants and fundamental vibrational frequencies are provided for the lower energy O-protonated isomer of this cation and its deuterated isotopologue. The vibrationally-averaged B0 and C0 rotational constants are within 6 MHz of their experimental values and the D(subJ) quartic distortion constants agree with experiment to within 3%. The known gas phase O-H stretch of NNOH(+) is 3330.91 cm(exp-1), and the vibrational configuration interaction computed result is 3330.9 cm(exp-1). Other spectroscopic constants are also provided, as are the rest of the fundamental vibrational frequencies for NNOH(+) and its deuterated isotopologue. This high-accuracy data should serve to better inform future observational or experimental studies of the rovibrational bands of protonated nitrous oxide in the ISM and the laboratory.

  9. On the Use of Maximum Force Criteria to Predict Localised Necking in Metal Sheets under Stretch-Bending

    Directory of Open Access Journals (Sweden)

    Domingo Morales-Palma

    2017-11-01

    Full Text Available The maximum force criteria and their derivatives, the Swift and Hill criteria, have been extensively used in the past to study sheet formability. Many extensions or modifications of these criteria have been proposed to improve necking predictions under only stretching conditions. This work analyses the maximum force principle under stretch-bending conditions and develops two different approaches to predict necking. The first is a generalisation of classical maximum force criteria to stretch-bending processes. The second approach is an extension of a previous work of the authors based on critical distance concepts, suggesting that necking of the sheet is controlled by the damage of a critical material volume located at the inner side of the sheet. An analytical deformation model is proposed to characterise the stretch-bending process under plane-strain conditions. Different parameters are considered, such as the thickness reduction, the gradient of variables through the sheet thickness, the thickness stress and the anisotropy of the material. The proposed necking models have been successfully applied to predict the failure in different materials, such as steel, brass and aluminium.

  10. Stability Analysis for Compliant Constant-Force Compression Mechanisms

    Directory of Open Access Journals (Sweden)

    Ikechukwu Celestine UGWUOKE

    2009-12-01

    Full Text Available Stability analysis in compliant mechanism (CM design is of utmostimportance. From a practical point of view, a CM that is unstable is of nosignificance (has no practical value. Three useful plots were considered in theevaluation of each of the dynamic models of nine configurations of compliantconstant-force compression mechanisms (CCFCMs for their stabilitycharacteristics, which includes the polar plot based on the Routh-Hurwitzstability criterion, the Bode plot, and the Nyquist diagram which considersstability in the real frequency domain. Frequency-domain stability criterion isvery useful for determining suitable approaches to adjusting the CCFCMparameters in order to increase its relative stability. The results obtained showthat the CCFCMs investigated do exhibit higher relative stability for highervalues of damping ratio, and for zero damping ratio, all the CCFCMsinvestigated were unstable. The result also show that for the CCFCMsinvestigated to be stable, damping ratio must be greater than 0.03 (ξ > 0.03and depending on what attributes are most desirable, the CCFCM parameterscan be optimized to achieve the desired results. Nyquist criterion provides uswith suitable information concerning the absolute stability and furthermore,can be utilized to define and ascertain the relative stability of a system.

  11. Influence of Poisson's ratio variation on lateral spring constant of atomic force microscopy cantilevers

    International Nuclear Information System (INIS)

    Yeh, M.-K.; Tai, N.-Ha; Chen, B.-Y.

    2008-01-01

    Atomic force microscopy (AFM) can be used to measure the surface morphologies and the mechanical properties of nanostructures. The force acting on the AFM cantilever can be obtained by multiplying the spring constant of AFM cantilever and the corresponding deformation. To improve the accuracy of force experiments, the spring constant of AFM cantilever must be calibrated carefully. Many methods, such as theoretical equations, the finite element method, and the use of reference cantilever, were reported to obtain the spring constant of AFM cantilevers. For the cantilever made of single crystal, the Poisson's ratio varies with different cantilever-crystal angles. In this paper, the influences of Poisson's ratio variation on the lateral spring constant and axial spring constant of rectangular and V-shaped AFM cantilevers, with different tilt angles and normal forces, were investigated by the finite element analysis. When the cantilever's tilt angle is 20 deg. and the Poisson's ratio varies from 0.02 to 0.4, the finite element results show that the lateral spring constants decrease 11.75% for the rectangular cantilever with 1 μN landing force and decrease 18.60% for the V-shaped cantilever with 50 nN landing force, respectively. The influence of Poisson's ratio variation on axial spring constant is less than 3% for both rectangular and V-shaped cantilevers. As the tilt angle increases, the axial spring constants for rectangular and V-shaped cantilevers decrease substantially. The results obtained can be used to improve the accuracy of the lateral force measurement when using atomic force microscopy

  12. Spring constant measurement using a MEMS force and displacement sensor utilizing paralleled piezoresistive cantilevers

    Science.gov (United States)

    Kohyama, Sumihiro; Takahashi, Hidetoshi; Yoshida, Satoru; Onoe, Hiroaki; Hirayama-Shoji, Kayoko; Tsukagoshi, Takuya; Takahata, Tomoyuki; Shimoyama, Isao

    2018-04-01

    This paper reports on a method to measure a spring constant on site using a micro electro mechanical systems (MEMS) force and displacement sensor. The proposed sensor consists of a force-sensing cantilever and a displacement-sensing cantilever. Each cantilever is composed of two beams with a piezoresistor on the sidewall for measuring the in-plane lateral directional force and displacement. The force resolution and displacement resolution of the fabricated sensor were less than 0.8 µN and 0.1 µm, respectively. We measured the spring constants of two types of hydrogel microparticles to demonstrate the effectiveness of the proposed sensor, with values of approximately 4.3 N m-1 and 15.1 N m-1 obtained. The results indicated that the proposed sensor is effective for on-site spring constant measurement.

  13. Changes in force and stiffness after static stretching of eccentrically-damaged hamstrings.

    Science.gov (United States)

    Matsuo, Shingo; Suzuki, Shigeyuki; Iwata, Masahiro; Hatano, Genki; Nosaka, Kazunori

    2015-05-01

    This study compared responses to static stretching between eccentrically damaged and non-damaged muscles. Twelve young men performed 60 maximum knee flexor eccentric contractions of one leg, and received a 300-s continuous passive static stretching at tolerable intensity without pain to both knee flexors at 2 and 4 days after the eccentric exercise. Range of motion (ROM) and passive stiffness during knee extension, passive torque at onset of pain (PT), maximum voluntary isometric (MVC-ISO) and isokinetic concentric contraction torque (MVC-CON), and visual analogue scale (VAS) for muscle soreness were measured before, immediately after, 60 min, 2 and 4 days after exercise as well as before, immediately after, 20 and 60 min after the stretching. Changes in these variables after eccentric exercise and stretching were compared between limbs. The eccentric exercise decreased MVC-ISO, MVC-CON, ROM and PT, and increased passive stiffness and VAS (p static stretching at tolerable intensity without pain produced greater positive effects on damaged than non-damaged muscles.

  14. Thrust Force Analysis of Tripod Constant Velocity Joint Using Multibody Model

    Science.gov (United States)

    Sugiura, Hideki; Matsunaga, Tsugiharu; Mizutani, Yoshiteru; Ando, Yosei; Kashiwagi, Isashi

    A tripod constant velocity joint is used in the driveshaft of front wheel drive vehicles. Thrust force generated by this joint causes lateral vibration in these vehicles. To analyze the thrust force, a detailed model is constructed based on a multibody dynamics approach. This model includes all principal parts of the joint defined as rigid bodies and all force elements of contact and friction acting among these parts. This model utilizes a new contact modeling method of needle roller bearings for more precise and faster computation. By comparing computational and experimental results, the appropriateness of this model is verified and the principal factors inducing the second and third rotating order components of the thrust force are clarified. This paper also describes the influence of skewed needle rollers on the thrust force and evaluates the contribution of friction forces at each contact region to the thrust force.

  15. Three days of intermittent stretching after muscle disuse alters the proteins involved in force transmission in muscle fibers in weanling rats.

    Science.gov (United States)

    Gianelo, M C S; Polizzelo, J C; Chesca, D; Mattiello-Sverzut, A C

    2016-02-01

    The aim of this study was to determine the effects of intermittent passive manual stretching on various proteins involved in force transmission in skeletal muscle. Female Wistar weanling rats were randomly assigned to 5 groups: 2 control groups containing 21- and 30-day-old rats that received neither immobilization nor stretching, and 3 test groups that received 1) passive stretching over 3 days, 2) immobilization for 7 days and then passive stretching over 3 days, or 3) immobilization for 7 days. Maximal plantar flexion in the right hind limb was imposed, and the stretching protocol of 10 repetitions of 30 s stretches was applied. The soleus muscles were harvested and processed for HE and picrosirius staining; immunohistochemical analysis of collagen types I, III, IV, desmin, and vimentin; and immunofluorescence labeling of dystrophin and CD68. The numbers of desmin- and vimentin-positive cells were significantly decreased compared with those in the control following immobilization, regardless of whether stretching was applied (Pstretching protocol was applied. In conclusion, the largest changes in response to stretching were observed in muscles that had been previously immobilized, and the stretching protocol applied here did not mitigate the immobilization-induced muscle changes. Muscle disuse adversely affected several proteins involved in the transmission of forces between the intracellular and extracellular compartments. Thus, the 3-day rehabilitation period tested here did not provide sufficient time for the muscles to recover from the disuse maladaptations in animals undergoing postnatal development.

  16. Heat and mass transfer of Williamson nanofluid flow yield by an inclined Lorentz force over a nonlinear stretching sheet

    Science.gov (United States)

    Khan, Mair; Malik, M. Y.; Salahuddin, T.; Hussian, Arif.

    2018-03-01

    The present analysis is devoted to explore the computational solution of the problem addressing the variable viscosity and inclined Lorentz force effects on Williamson nanofluid over a stretching sheet. Variable viscosity is assumed to vary as a linear function of temperature. The basic mathematical modelled problem i.e. system of PDE's is converted nonlinear into ODE's via applying suitable transformations. Computational solutions of the problem is also achieved via efficient numerical technique shooting. Characteristics of controlling parameters i.e. stretching index, inclined angle, Hartmann number, Weissenberg number, variable viscosity parameter, mixed convention parameter, Brownian motion parameter, Prandtl number, Lewis number, thermophoresis parameter and chemical reactive species on concentration, temperature and velocity gradient. Additionally, friction factor coefficient, Nusselt number and Sherwood number are describe with the help of graphics as well as tables verses flow controlling parameters.

  17. Heat and mass transfer of Williamson nanofluid flow yield by an inclined Lorentz force over a nonlinear stretching sheet

    Directory of Open Access Journals (Sweden)

    Mair Khan

    2018-03-01

    Full Text Available The present analysis is devoted to explore the computational solution of the problem addressing the variable viscosity and inclined Lorentz force effects on Williamson nanofluid over a stretching sheet. Variable viscosity is assumed to vary as a linear function of temperature. The basic mathematical modelled problem i.e. system of PDE’s is converted nonlinear into ODE’s via applying suitable transformations. Computational solutions of the problem is also achieved via efficient numerical technique shooting. Characteristics of controlling parameters i.e. stretching index, inclined angle, Hartmann number, Weissenberg number, variable viscosity parameter, mixed convention parameter, Brownian motion parameter, Prandtl number, Lewis number, thermophoresis parameter and chemical reactive species on concentration, temperature and velocity gradient. Additionally, friction factor coefficient, Nusselt number and Sherwood number are describe with the help of graphics as well as tables verses flow controlling parameters. Keywords: Williamson nanofluid, Temperature depended viscosity, Inclined magnetic field, Mixed convection, Chemical reactive species, Variable viscosity, Shooting method

  18. The effects of rigid motions on elastic network model force constants.

    Science.gov (United States)

    Lezon, Timothy R

    2012-04-01

    Elastic network models provide an efficient way to quickly calculate protein global dynamics from experimentally determined structures. The model's single parameter, its force constant, determines the physical extent of equilibrium fluctuations. The values of force constants can be calculated by fitting to experimental data, but the results depend on the type of experimental data used. Here, we investigate the differences between calculated values of force constants and data from NMR and X-ray structures. We find that X-ray B factors carry the signature of rigid-body motions, to the extent that B factors can be almost entirely accounted for by rigid motions alone. When fitting to more refined anisotropic temperature factors, the contributions of rigid motions are significantly reduced, indicating that the large contribution of rigid motions to B factors is a result of over-fitting. No correlation is found between force constants fit to NMR data and those fit to X-ray data, possibly due to the inability of NMR data to accurately capture protein dynamics. Copyright © 2011 Wiley Periodicals, Inc.

  19. Development of Device to Evoke Stretch Reflexes by Use of Electromagnetic Force for the Rehabilitation of the Hemiplegic Upper Limb after Stroke

    Science.gov (United States)

    Hayashi, Ryota; Ishimine, Tomoyasu; Kawahira, Kazumi; Yu, Yong; Tsujio, Showzow

    In this research, we focus on the method of rehabilitation with stretch reflexes for the hemiplegic upper limb in stroke patients. We propose a new device which utilizes electromagnetic force to evoke stretch reflexes. The device can exert an assisting force safely, because the electromagnetic force is non contact force. In this paper, we develop a support system applying the proposed device for the functional recovery training of the hemiplegic upper limb. The results obtained from several clinical tests with and without our support system are compared. Then we discuss the validity of our support system.

  20. Practical Considerations for Using Constant Force Springs in Space-Based Mechanisms

    Science.gov (United States)

    Williams, R. Brett; Fisher, Charles D.; Gallon, John C.

    2013-01-01

    Mechanical springs are a common element in mechanism from all walks of life; cars, watches, appliances, and many others. These springs generally exhibit a linear relationship between force and deflection. In small mechanisms, deflections are small so the variation in spring force between one position and another are generally small and do not influence the design or functionality of the device. However, as the spacecraft industry drives towards larger, deployable satellites, the distances a spring or springs must function over can become considerable so much so that the structural integrity of the device may be impacted. As such, an increasingly common mechanism element is the constant force spring- one that provides a constant force regardless of deflection. These elements are commonly in the conceptual design phase to deal with system-level large deflections, but in the detailed design or integration test phase they can pose significant implementation issues. This article addresses some of the detailed issues in order for these constant force springs to be properly designed into space systems.

  1. The effect of maintaining a constant preload or a constant degree of thumb abduction on the isometric twitch force of the thumb

    NARCIS (Netherlands)

    van Santen, G; Wierda, JMKH

    Objective. To investigate the effects of maintaining a constant preload and of maintaining a constant degree of thumb abduction on the isometric twitch force during mechanomyography of the thumb, we monitored neuromuscular function in patients anaesthetized without the use of a neuromuscular

  2. Links between the charge model and bonded parameter force constants in biomolecular force fields

    Science.gov (United States)

    Cerutti, David S.; Debiec, Karl T.; Case, David A.; Chong, Lillian T.

    2017-10-01

    The ff15ipq protein force field is a fixed charge model built by automated tools based on the two charge sets of the implicitly polarized charge method: one set (appropriate for vacuum) for deriving bonded parameters and the other (appropriate for aqueous solution) for running simulations. The duality is intended to treat water-induced electronic polarization with an understanding that fitting data for bonded parameters will come from quantum mechanical calculations in the gas phase. In this study, we compare ff15ipq to two alternatives produced with the same fitting software and a further expanded data set but following more conventional methods for tailoring bonded parameters (harmonic angle terms and torsion potentials) to the charge model. First, ff15ipq-Qsolv derives bonded parameters in the context of the ff15ipq solution phase charge set. Second, ff15ipq-Vac takes ff15ipq's bonded parameters and runs simulations with the vacuum phase charge set used to derive those parameters. The IPolQ charge model and associated protocol for deriving bonded parameters are shown to be an incremental improvement over protocols that do not account for the material phases of each source of their fitting data. Both force fields incorporating the polarized charge set depict stable globular proteins and have varying degrees of success modeling the metastability of short (5-19 residues) peptides. In this particular case, ff15ipq-Qsolv increases stability in a number of α -helices, correctly obtaining 70% helical character in the K19 system at 275 K and showing appropriately diminishing content up to 325 K, but overestimating the helical fraction of AAQAA3 by 50% or more, forming long-lived α -helices in simulations of a β -hairpin, and increasing the likelihood that the disordered p53 N-terminal peptide will also form a helix. This may indicate a systematic bias imparted by the ff15ipq-Qsolv parameter development strategy, which has the hallmarks of strategies used to develop

  3. Note: Determination of torsional spring constant of atomic force microscopy cantilevers: Combining normal spring constant and classical beam theory

    DEFF Research Database (Denmark)

    Álvarez-Asencio, R.; Thormann, Esben; Rutland, M.W.

    2013-01-01

    A technique has been developed for the calculation of torsional spring constants for AFM cantilevers based on the combination of the normal spring constant and plate/beam theory. It is easy to apply and allow the determination of torsional constants for stiff cantilevers where the thermal power...

  4. Calculation of the mean force constants of the rare gases and the rectilinear law of mean force

    International Nuclear Information System (INIS)

    Lee, M.W.; Bigeleisen, J.

    1977-01-01

    The mean energies, (U), and the mean force constants, (nabla 2 U), have been calculated for liquid argon and liquid krypton using the WCA perturbation theory, and for gaseous argon and krypton along the coexistence line by solution of the PY equation for the radial distribution function. Calculations have been made for the Lennard-Jones, Barker-Henderson, and Maitland-Smith potentials. There is little difference in the values of (U) and (nabla 2 U) calculated for the three potentials. The calculated values are in good agreement with experimental data. Correlation of the calculated values of (nabla 2 U) for the liquid and gas leads to an empirical relationship between (nabla 2 U) and the density of the phase along the coexistence line. When the latter is combined with the law of rectilinear diameters of the density, the rectilinear law of mean force is obtained, which is in good agreement with experimental data on argon. It is shown that the scaling exponent for the mean force constant, (nabla 2 U)/sub l/-(nabla 2 U)/sub g/, is larger than the scaling exponent of the density below the critical temperature and becomes equal to it at the critical temperature. The rationale for the rectilinear law of mean force is provided by an expansion of the radial distribution function of the liquid in powers of the density and the use of the WCA approximation to the radial distribution function

  5. Stretching single DNA molecules to demonstrate high-force capabilities of holographic optical tweezers

    NARCIS (Netherlands)

    Farré, Arnau; van der Horst, Astrid; Blab, Gerhard A.; Downing, Benjamin P. B.; Forde, Nancy R.

    2010-01-01

    The well calibrated force-extension behaviour of single double-stranded DNA molecules was used as a standard to investigate the performance of phase-only holographic optical tweezers at high forces. Specifically, the characteristic overstretch transition at 65 pN was found to appear where expected,

  6. Stretching single DNA molecules to demonstrate high-force capabilities of holographic optical tweezers.

    Science.gov (United States)

    Farré, Arnau; van der Horst, Astrid; Blab, Gerhard A; Downing, Benjamin P B; Forde, Nancy R

    2010-04-01

    The well calibrated force-extension behaviour of single double-stranded DNA molecules was used as a standard to investigate the performance of phase-only holographic optical tweezers at high forces. Specifically, the characteristic overstretch transition at 65 pN was found to appear where expected, demonstrating (1) that holographic optical trap calibration using thermal fluctuation methods is valid to high forces; (2) that the holographic optical traps are harmonic out to >250 nm of 2.1 mum particle displacement; and (3) that temporal modulations in traps induced by the spatial light modulator (SLM) do not affect the ability of optical traps to hold and steer particles against high forces. These studies demonstrate a new high-force capability for holographic optical traps achievable by SLM technologies. ((c) 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim).

  7. An analytic model for accurate spring constant calibration of rectangular atomic force microscope cantilevers.

    Science.gov (United States)

    Li, Rui; Ye, Hongfei; Zhang, Weisheng; Ma, Guojun; Su, Yewang

    2015-10-29

    Spring constant calibration of the atomic force microscope (AFM) cantilever is of fundamental importance for quantifying the force between the AFM cantilever tip and the sample. The calibration within the framework of thin plate theory undoubtedly has a higher accuracy and broader scope than that within the well-established beam theory. However, thin plate theory-based accurate analytic determination of the constant has been perceived as an extremely difficult issue. In this paper, we implement the thin plate theory-based analytic modeling for the static behavior of rectangular AFM cantilevers, which reveals that the three-dimensional effect and Poisson effect play important roles in accurate determination of the spring constants. A quantitative scaling law is found that the normalized spring constant depends only on the Poisson's ratio, normalized dimension and normalized load coordinate. Both the literature and our refined finite element model validate the present results. The developed model is expected to serve as the benchmark for accurate calibration of rectangular AFM cantilevers.

  8. Acute effect of static stretching on rate of force development and maximal voluntary contraction in older women.

    Science.gov (United States)

    Gurjão, André L D; Gonçalves, Raquel; de Moura, Rodrigo F; Gobbi, Sebastião

    2009-10-01

    The purpose of this study was to investigate, in older women, the acute effect of static stretching (SS) on both muscle activation and force output. Twenty-three older women (64.6 +/- 7.1 yr) participated in the study. The maximal voluntary contraction (MVC), rate of force development (RFD) (50, 100, 150, and 200 ms relative to onset of muscular contraction), and peak RFD (PRFD) (the steepest slope of the curve during the first 200 ms) were tested under 2 randomly separate conditions: SS and control (C). Electromyographic (EMG) activity of the vastus medialis (VM), vastus lateralis (VL), and biceps femoris (BF) muscles also was assessed. The MVC was significantly lower (p force decreased after their performance of SS exercises. The mechanisms responsible for this effect do not appear to be related to muscle activation. Thus, if flexibility is to be trained, it is recommended that SS does not occur just before the performance of activities that require high levels of muscular force.

  9. Deformations of a pre-stretched and lubricated finite elastic membrane driven by non-uniform external forcing

    Science.gov (United States)

    Boyko, Evgeniy; Gat, Amir; Bercovici, Moran

    2017-11-01

    We study viscous-elastic dynamics of a fluid confined between a rigid plate and a finite pre-stretched circular elastic membrane, pinned at its boundaries. The membrane is subjected to forces acting either directly on the membrane or through a pressure distribution in the fluid. Under the assumptions of strong pre-stretching and small deformations of the elastic sheet, and by applying the lubrication approximation for the flow, we derive the Green's function for the resulting linearized 4th order diffusion equation governing the deformation field in cylindrical coordinates. In addition, defining an asymptotic expansion with the ratio of the induced to prescribed tension serving as the small parameter, we reduce the coupled Reynolds and non-linear von-Karman equations to a set of three one-way coupled linear equations. The solutions to these equations provide insight onto the effects of induced tension, and enable simplified prediction of the correction for the deformation field. Funded by the European Research Council (ERC) under the European Union'sHorizon 2020 Research and Innovation Programme, Grant Agreement No. 678734 (MetamorphChip). E.B. is supported by the Adams Fellowship Program.

  10. Relativistic force field: parametric computations of proton-proton coupling constants in (1)H NMR spectra.

    Science.gov (United States)

    Kutateladze, Andrei G; Mukhina, Olga A

    2014-09-05

    Spin-spin coupling constants in (1)H NMR carry a wealth of structural information and offer a powerful tool for deciphering molecular structures. However, accurate ab initio or DFT calculations of spin-spin coupling constants have been very challenging and expensive. Scaling of (easy) Fermi contacts, fc, especially in the context of recent findings by Bally and Rablen (Bally, T.; Rablen, P. R. J. Org. Chem. 2011, 76, 4818), offers a framework for achieving practical evaluation of spin-spin coupling constants. We report a faster and more precise parametrization approach utilizing a new basis set for hydrogen atoms optimized in conjunction with (i) inexpensive B3LYP/6-31G(d) molecular geometries, (ii) inexpensive 4-31G basis set for carbon atoms in fc calculations, and (iii) individual parametrization for different atom types/hybridizations, not unlike a force field in molecular mechanics, but designed for the fc's. With the training set of 608 experimental constants we achieved rmsd <0.19 Hz. The methodology performs very well as we illustrate with a set of complex organic natural products, including strychnine (rmsd 0.19 Hz), morphine (rmsd 0.24 Hz), etc. This precision is achieved with much shorter computational times: accurate spin-spin coupling constants for the two conformers of strychnine were computed in parallel on two 16-core nodes of a Linux cluster within 10 min.

  11. Impact of uncertainties in inorganic chemical rate constants on tropospheric composition and ozone radiative forcing

    Directory of Open Access Journals (Sweden)

    B. Newsome

    2017-12-01

    regions such as the tropics, poles and upper troposphere are most uncertain. This chemical uncertainty is sufficiently large to suggest that rate constant uncertainty should be considered alongside other processes when model results disagree with measurement. Calculations for the pre-industrial simulation allow a tropospheric ozone radiative forcing to be calculated of 0.412 ± 0.062 W m−2. This uncertainty (13 % is comparable to the inter-model spread in ozone radiative forcing found in previous model–model intercomparison studies where the rate constants used in the models are all identical or very similar. Thus, the uncertainty of tropospheric ozone radiative forcing should expanded to include this additional source of uncertainty. These rate constant uncertainties are significant and suggest that refinement of supposedly well-known chemical rate constants should be considered alongside other improvements to enhance our understanding of atmospheric processes.

  12. Impact of uncertainties in inorganic chemical rate constants on tropospheric composition and ozone radiative forcing

    Science.gov (United States)

    Newsome, Ben; Evans, Mat

    2017-12-01

    model intercomparisons. Remote regions such as the tropics, poles and upper troposphere are most uncertain. This chemical uncertainty is sufficiently large to suggest that rate constant uncertainty should be considered alongside other processes when model results disagree with measurement. Calculations for the pre-industrial simulation allow a tropospheric ozone radiative forcing to be calculated of 0.412 ± 0.062 W m-2. This uncertainty (13 %) is comparable to the inter-model spread in ozone radiative forcing found in previous model-model intercomparison studies where the rate constants used in the models are all identical or very similar. Thus, the uncertainty of tropospheric ozone radiative forcing should expanded to include this additional source of uncertainty. These rate constant uncertainties are significant and suggest that refinement of supposedly well-known chemical rate constants should be considered alongside other improvements to enhance our understanding of atmospheric processes.

  13. Spring constant calibration of atomic force microscope cantilevers of arbitrary shape

    International Nuclear Information System (INIS)

    Sader, John E.; Sanelli, Julian A.; Adamson, Brian D.; Bieske, Evan J.; Monty, Jason P.; Marusic, Ivan; Wei Xingzhan; Mulvaney, Paul; Crawford, Simon A.; Friend, James R.

    2012-01-01

    The spring constant of an atomic force microscope cantilever is often needed for quantitative measurements. The calibration method of Sader et al. [Rev. Sci. Instrum. 70, 3967 (1999)] for a rectangular cantilever requires measurement of the resonant frequency and quality factor in fluid (typically air), and knowledge of its plan view dimensions. This intrinsically uses the hydrodynamic function for a cantilever of rectangular plan view geometry. Here, we present hydrodynamic functions for a series of irregular and non-rectangular atomic force microscope cantilevers that are commonly used in practice. Cantilever geometries of arrow shape, small aspect ratio rectangular, quasi-rectangular, irregular rectangular, non-ideal trapezoidal cross sections, and V-shape are all studied. This enables the spring constants of all these cantilevers to be accurately and routinely determined through measurement of their resonant frequency and quality factor in fluid (such as air). An approximate formulation of the hydrodynamic function for microcantilevers of arbitrary geometry is also proposed. Implementation of the method and its performance in the presence of uncertainties and non-idealities is discussed, together with conversion factors for the static and dynamic spring constants of these cantilevers. These results are expected to be of particular value to the design and application of micro- and nanomechanical systems in general.

  14. Standard practice for verification of constant amplitude dynamic forces in an axial fatigue testing system

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This practice covers procedures for the dynamic verification of cyclic force amplitude control or measurement accuracy during constant amplitude testing in an axial fatigue testing system. It is based on the premise that force verification can be done with the use of a strain gaged elastic element. Use of this practice gives assurance that the accuracies of forces applied by the machine or dynamic force readings from the test machine, at the time of the test, after any user applied correction factors, fall within the limits recommended in Section 9. It does not address static accuracy which must first be addressed using Practices E 4 or equivalent. 1.2 Verification is specific to a particular test machine configuration and specimen. This standard is recommended to be used for each configuration of testing machine and specimen. Where dynamic correction factors are to be applied to test machine force readings in order to meet the accuracy recommended in Section 9, the verification is also specific to the c...

  15. Effect of the ion force on the hydrolysis constants and of the solubility product of Europium

    International Nuclear Information System (INIS)

    Jimenez R, M.; Ramirez G, J.J.; Solache R, M.; Rojas H, A.

    2003-01-01

    A study on the behavior of the first hydrolysis constant β Eu,H l-0 and the constant of the solubility product Kps of the europium in front of the changes of the ion force: 0. 02 M, 0.1 M, 0.7M, 2M, 3M and 4M of sodium perchlorate, at 303 K. Experimentally the potentiometry and also radioactivity measures its were used. The specific interaction of ions theory (SIT) of Bronsted-Guggenheim-Scatchard allows the extrapolation of the values to infinite dilution and the results were: log β Eu,H l-0 = -7 36 and log K sp l-0 = -24. 68. A discussion of the group of results with the data of the literature is presented. (Author)

  16. Stretch-induced force deficits in murine extensor digitorum longus muscles after cardiotoxin injection.

    Science.gov (United States)

    Markert, Chad; Petroski, Gregory F; Childers, Charles K; McDonald, Kerry S; Childers, Martin K

    2006-10-01

    A leftward shift in a muscle's length-tension relationship is thought to impair myofilament overlap. We hypothesized that left-shifted muscles would incur greater eccentric contraction-induced damage compared to controls. We evaluated contractile properties and force deficits in regenerating murine extensor digitorum longus (EDL) muscles 7, 14, and 21 days after cardiotoxin (CTX) injection. Specific tension recovered to control values by 21 days. CTX-injected muscles demonstrated left-shifted length-tension curves and incurred greater contraction-induced force deficits than controls (P < 0.001) on day 7. We speculate that increased contraction-induced damage in 7-day CTX-injected muscles results from changes in myofilament overlap that occurs during early regeneration.

  17. Cellular Tug-of-War: Forces at Work and DNA Stretching in Mitosis

    Science.gov (United States)

    Griffin, Brian; Kilfoil, Maria L.

    2013-03-01

    In the microscopic world of the cell dominated by thermal noise, a cell must be able to successfully segregate its DNA with high fidelity in order to pass its genetic information on to its progeny. In this process of mitosis in eukaryotes, driving forces act on the cytoskeleton-based architecture called the mitotic spindle to promote this division. Our preliminary data demonstrates that the dynamics of this process in yeast cells is universal. Moreover, the dynamics suggest an increasing load as the chromosomes are pulled apart. To investigate this, we use three-dimensional imaging to track the dynamics of the poles of this architecture and the points of attachment to chromosomes simultaneously and with high spatial resolution. We analyze the relative motions of chromosomes as they are organized before segregation and as they are pulled apart, using this data to investigate the force-response behavior of this cytoskeleton-chromosome polymer system.

  18. Derivation of Inter-Atomic Force Constants of Cu2O from Diffuse Neutron Scattering Measurement

    Directory of Open Access Journals (Sweden)

    T. Makhsun

    2013-04-01

    Full Text Available Neutron scattering intensity from Cu2O compound has been measured at 10 K and 295 K with High Resolution Powder Diffractometer at JRR-3 JAEA. The oscillatory diffuse scattering related to correlations among thermal displacements of atoms was observed at 295 K. The correlation parameters were determined from the observed diffuse scattering intensity at 10 and 295 K. The force constants between the neighboring atoms in Cu2O were estimated from the correlation parameters and compared to those of Ag2O

  19. Standard practice for conducting force controlled constant amplitude axial fatigue tests of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This practice covers the procedure for the performance of axial force controlled fatigue tests to obtain the fatigue strength of metallic materials in the fatigue regime where the strains are predominately elastic, both upon initial loading and throughout the test. This practice is limited to the fatigue testing of axial unnotched and notched specimens subjected to a constant amplitude, periodic forcing function in air at room temperature. This practice is not intended for application in axial fatigue tests of components or parts. Note 1-The following documents, although not directly referenced in the text, are considered important enough to be listed in this practice: E 739 Practice for Statistical Analysis of Linear or Linearized Stress-Life (S-N) and Strain-Life (-N) Fatigue Data STP 566 Handbook of Fatigue Testing STP 588 Manual on Statistical Planning and Analysis for Fatigue Experiments STP 731 Tables for Estimating Median Fatigue Limits

  20. A simple constrained uniaxial tensile apparatus for in situ investigation of film stretching processing.

    Science.gov (United States)

    Meng, Lingpu; Li, Jing; Cui, Kunpeng; Chen, Xiaowei; Lin, Yuanfei; Xu, Jiali; Li, Liangbin

    2013-11-01

    A simple constrained uniaxial tensile apparatus was designed and constructed to obtain stress-strain curve during stretching and subsequent structural evolution of polymeric films. Stretch is carried out through two motor driven clamps in the machine direction and scissor-like clamps in the transverse direction keeping the sample width constant. The force information during film stretching process is recorded by a tension sensor and structural evolution can be obtained by in situ X-ray scattering technique. All parameters related to film stretching manufacturing, such as temperature, draw ratio, and stretching speed can be set independently, making the apparatus an effective method to explore the relationship between processing parameters and structure.

  1. Average velocity and effective diffusion of a Brownian particle driven by a constant force over a static periodic potential

    OpenAIRE

    Wang, Hongyun

    2006-01-01

    In this manuscript, we consider the case where a Brownian particle is subject to a static periodic potential and is driven by a constant force. We derive analytic formulas for the average velocity and the effective diffusion.

  2. Determination of lutetium (III) hydrolysis constants in the middle of ion force 1M sodium chloride at 303 K

    International Nuclear Information System (INIS)

    Jimenez R, M.; Solache R, M.J.; Ramirez G, J.J.; Rojas H, A.

    1997-01-01

    With the purpose to complete information about the lutetium (III) hydrolysis constants here is used the potentiometric method to determine those in the middle of ion force 1M sodium chloride at 303 K. (Author)

  3. Numerical study of entropy generation for forced convection flow and heat transfer of a Jeffrey fluid over a stretching sheet

    Directory of Open Access Journals (Sweden)

    Nemat Dalir

    2014-12-01

    Full Text Available Entropy generation for the steady two-dimensional laminar forced convection flow and heat transfer of an incompressible Jeffrey non-Newtonian fluid over a linearly stretching, impermeable and isothermal sheet is numerically investigated. The governing differential equations of continuity, momentum and energy are transformed using suitable similarity transformations to two nonlinear coupled ordinary differential equations (ODEs. Then the ODEs are solved by applying the numerical implicit Keller’s box method. The effects of various parameters of the flow and heat transfer including Deborah number, ratio of relaxation to retardation times, Prandtl number, Eckert number, Reynolds number and Brinkman number on dimensionless velocity, temperature and entropy generation number profiles are analyzed. The results reveal that the entropy generation number increases with the increase of Deborah number while the increase of ratio of relaxation to retardation times causes the entropy generation number to reduce. A comparative study of the numerical results with the results from an exact solution for the dimensionless velocity gradient at the sheet surface is also performed. The comparison shows excellent agreement within 0.05% error.

  4. Influence of inclined Lorentz forces on boundary layer flow of Casson fluid over an impermeable stretching sheet with heat transfer

    Energy Technology Data Exchange (ETDEWEB)

    Abdul Hakeem, A.K., E-mail: abdulhakeem6@gmail.com [Department of Mathematics, Sri Ramakrishna Mission Vidyalaya, College of Arts and Science, Coimbatore 641 020 (India); Renuka, P. [Department of Mathematics, Erode Sengunthar Engineering college, Erode 638 057 (India); Vishnu Ganesh, N.; Kalaivanan, R. [Department of Mathematics, Sri Ramakrishna Mission Vidyalaya, College of Arts and Science, Coimbatore 641 020 (India); Ganga, B. [Department of Mathematics, Providence College for Women, Coonoor 643 104 (India)

    2016-03-01

    The inclined magnetic field effect on the boundary layer flow of a Casson model non-Newtonian fluid over a stretching sheet in the existence of thermal radiation and velocity slip boundary condition is investigated for both prescribed surface temperature and power law of surface heat flux cases. It is assumed that the magnetic field is applied with an aligned angle which varied from 0° to 90°. Both analytical and numerical solutions are obtained for the transformed non-dimensional ODE's using confluent hypergeometric function and fourth order Runge–Kutta method with shooting technique respectively. The combined effects of inclined magnetic field with other pertinent parameters such as Casson parameter, velocity slip parameter, radiation parameter and Prandtl number on velocity profile, temperature profile, local skin friction coefficient, local Nusselt number and non-dimensional wall temperature are discussed through graphs. It is found that the aligned angle plays a vital role in controlling the magnetic field strength on the Casson fluid flow region and the increasing values of aligned angle of the magnetic field lead to decrease the skin friction coefficient and the Nusselt number and increase the non-dimensional wall temperature. - Highlights: • Casson fluid flow in the presence of inclined magnetic field is investigated for the first time. • Aligned angle controls the magnetic field strength on the boundary layer flow region. • The direction of Lorentz force changes according to aligned angle. • An excellent agreement is observed between present analytical and numerical results.

  5. Calibration of higher eigenmode spring constants of atomic force microscope cantilevers

    Energy Technology Data Exchange (ETDEWEB)

    Lozano, Jose R; Garcia, Ricardo [IMM-Instituto de Microelectronica de Madrid (CNM-CSIC), Isaac Newton 8, PTM, E-28760 Tres Cantos, Madrid (Spain); Kiracofe, Daniel; Melcher, John; Raman, Arvind, E-mail: raman@purdue.edu [Birck Nanotechnology Center and School of Mechanical Engineering, Purdue University, West Lafayette, IN 47904-2088 (United States)

    2010-11-19

    Standard spring constant calibration methods are compared when applied to higher eigenmodes of cantilevers used in dynamic atomic force microscopy (dAFM). Analysis shows that Sader's original method (Sader et al 1999 Rev. Sci. Instrum. 70 3967-9), which relies on a priori knowledge of the eigenmode shape, is poorly suited for the calibration of higher eigenmodes. On the other hand, the thermal noise method (Hutter and Bechhoefer 1993 Rev. Sci. Instrum. 64 1868-73) does not require knowledge of the eigenmode and remains valid for higher eigenmodes of the dAFM probe. Experimental measurements of thermal vibrations in air for three representative cantilevers are provided to support the theoretical results.

  6. Acute effect of static stretching on muscle force in older women DOI:10.5007/1980-0037.2010v12n3p195

    Directory of Open Access Journals (Sweden)

    André Luiz Demantova Gurjão

    2010-01-01

    Full Text Available The objective of this study was to investigate the acute effect of static stretching on the peak rate of force development (PRFD and maximum voluntary contraction (MVC in older women. Ten women (68.5 ± 7.0 years; 70.9 ± 8.1 kg; 159.4 ± 6.0 cm; body mass index: 28.0 ± 3.8 kg/m2 were studied. MVC and PRFD were determined by leg press exercise before and after the control or stretching condition (three sets of 30 seconds of static stretching of the quadriceps on two different days (interval of 24 hours. PRFD was determined as the steepest slope of the curve, calculated within regular windows of 20 milliseconds (∆force/∆time for the first 200 milliseconds after the onset of contraction. MVC was determined as the highest value recorded in each set. Only one condition was tested on each day and the order of application of each condition was determined randomly. The stretching intensity was evaluated by the muscle pain threshold. Four post-condition assessments (post-treatment, 10, 20, and 30 minutes were performed to monitor muscle strength. ANCOVA 2x5, followed by the Scheffé post-hoc test, showed no significant interactions between conditions vs. times (P > 0.05 for PRFD or MVC. In conclusion, acute bouts of static stretching of the quadriceps femoris do not affect the ability of rapid and maximum muscle force production in older women.

  7. Morphodynamics and stratigraphic architecture of shelf-edge deltas subject to constant vs. dynamic environmental forcings

    Science.gov (United States)

    Straub, K. M.

    2017-12-01

    When deltas dock at the edge of continental margins they generally construct thick stratigraphic intervals and activate channelized continental slope systems. Deposits of shelf-edge deltas have the capacity to store detailed paleo-environmental records, given their location in the source to sink system. However, present day highstand sea-level conditions have pushed most deltaic systems well inbound of their shelf-edges, making it difficult to study their space-time dynamics and resulting stratigraphic products. Several competing theories describe how deltas and their downslope environments respond to sea-level cycles of varying magnitude and periodicity. We explore these hypotheses in a physical experiment where the topographic evolution of a coupled delta and downdip slope system was monitored at high temporal and spatial resolution. The experiment had three stages. In the first stage a delta aggraded at the shelf-edge under constant water and sediment supply, in addition to a constant generation of accommodation through a sea-level rise. In the second stage the sediment transport system responded to low magnitude and high frequency sea-level cycles. Finally, in the third stage the transport system responded to a high magnitude and long period sea-level cycle. In each stage, fine sediment from the input grain size distribution and dissolved salt in the input water supply promoted plunging hyperpycnal flows. Specifically, we compare the mean and temporal variability of the sediment delivered to the slope system between stages. In addition, we compare stratigraphic architecture and sediment sizes delivered to the slope system in each stage. These results are used to improve inversion of slope deposits for paleo-environmental forcings.

  8. Contrast inversion in electrostatic force microscopy imaging of trapped charges: tip-sample distance and dielectric constant dependence

    Energy Technology Data Exchange (ETDEWEB)

    Riedel, C; AlegrIa, A; Colmenero, J [Departamento de Fisica de Materiales UPV/EHU, Facultad de Quimica, Apartado 1072, 20080 San Sebastian (Spain); Arinero, R [Institut d' Electronique du Sud (IES), UMR CNRS 5214, Universite Montpellier II, CC 082, Place E Bataillon, 34095 Montpellier Cedex (France); Saenz, J J, E-mail: riedel@ies.univ-montp2.fr [Donostia International Physics Center, Paseo Manuel de Lardizabal 4, 20018 San Sebastian (Spain)

    2011-08-26

    We present a numerical and analytical study of the behavior of both electrostatic force and force gradient created by a charge trapped below the surface of a dielectric on an atomic force microscope tip as a function of the dielectric constant and tip-sample distance. As expected, the force decreases monotonously when the dielectric constant increases. However, a maximum in the dielectric constant dependence of the force gradient is found. This maximum occurs in the typical experimental parameters' range and depends on the tip-sample distance and the sample thickness. The analytical study permits us to understand the physical origin of this phenomenon and is in good agreement with the numerical simulation for small tip-sample distances. We also report a study exemplifying a possible contrast inversion in electrostatic force microscopy (EFM) signals while scanning, at different heights, two charges trapped in a sample having heterogeneous dielectric domains. In addition to this particular contrast inversion effect, this study can be considered as a way to gain insight into the mechanisms of EFM image formation as a function of the dielectric constant and tip-sample.

  9. Contact-free experimental determination of the static flexural spring constant of cantilever sensors using a microfluidic force tool.

    Science.gov (United States)

    Parkin, John D; Hähner, Georg

    2016-01-01

    Micro- and nanocantilevers are employed in atomic force microscopy (AFM) and in micro- and nanoelectromechanical systems (MEMS and NEMS) as sensing elements. They enable nanomechanical measurements, are essential for the characterization of nanomaterials, and form an integral part of many nanoscale devices. Despite the fact that numerous methods described in the literature can be applied to determine the static flexural spring constant of micro- and nanocantilever sensors, experimental techniques that do not require contact between the sensor and a surface at some point during the calibration process are still the exception rather than the rule. We describe a noncontact method using a microfluidic force tool that produces accurate forces and demonstrate that this, in combination with a thermal noise spectrum, can provide the static flexural spring constant for cantilever sensors of different geometric shapes over a wide range of spring constant values (≈0.8-160 N/m).

  10. Contact-free experimental determination of the static flexural spring constant of cantilever sensors using a microfluidic force tool

    Directory of Open Access Journals (Sweden)

    John D. Parkin

    2016-03-01

    Full Text Available Micro- and nanocantilevers are employed in atomic force microscopy (AFM and in micro- and nanoelectromechanical systems (MEMS and NEMS as sensing elements. They enable nanomechanical measurements, are essential for the characterization of nanomaterials, and form an integral part of many nanoscale devices. Despite the fact that numerous methods described in the literature can be applied to determine the static flexural spring constant of micro- and nanocantilever sensors, experimental techniques that do not require contact between the sensor and a surface at some point during the calibration process are still the exception rather than the rule. We describe a noncontact method using a microfluidic force tool that produces accurate forces and demonstrate that this, in combination with a thermal noise spectrum, can provide the static flexural spring constant for cantilever sensors of different geometric shapes over a wide range of spring constant values (≈0.8–160 N/m.

  11. Contribution of the tendinous tissue to force enhancement during stretch-shortening cycle exercise depends on the prestretch and concentric phase intensities.

    Science.gov (United States)

    Ishikawa, Masaki; Komi, Paavo V; Finni, Taija; Kuitunen, Sami

    2006-10-01

    When the prestretch intensity and concentric work are increased in stretch-shortening cycle (SSC) exercises, the utilization of the elastic energy can increase during the concentric phase. In order to further understand this process during SSC exercises, the interaction between fascicle-tendinous tissues (TT) of the vastus lateralis (VL) muscle was examined under different prestretch and rebound intensity drop jumps. Ten male subjects participated in the study. Direct VL fascicle lengths (N = 10) and in vivo patellar tendon force (N = 1) were measured together with the electromyographic (EMG) activity of VL during the trials. With increasing drop height but the same rebound height condition, the TT stretch increased during the early braking phase with a subsequent increase in its recoil during the early push-off phase. This occurred concomitantly with decreased fascicle shortening and EMG activation. However, with the increased rebound height but the same drop height condition, the fascicles were stretched less during the late braking phase with higher EMG activation. In this situation, TT could be stretched more by the tension provided by fascicles. Consequently, the TT recoil increased during the late push-off phase. These observations confirm that there can be an intensity specific fascicle-TT interaction during SSC exercises.

  12. DFT calculations for anharmonic force field and spectroscopic constants of YC2 and its 13C isotopologues

    Science.gov (United States)

    Zhao, Yanliang; Wang, Meishan; Yang, Chuanlu; Ma, Xiaoguang; Li, Jing

    2018-02-01

    The construction of the complete third and the semi-diagonal quartic force fields including the anharmonicity of the ground state (X˜2A1) for yttrium dicarbide (YC2) is carried out employing the vibrational second-order perturbation theory (VPT2) in combination with the density functional theory (DFT). The equilibrium geometries optimization, anharmonic force field and vibrational spectroscopic constants of YC2 are calculated by B3LYP, B3PW91 and B3P86 methods. Aug-cc-pVnZ (n = D, T, Q) and cc-pVnZ-PP (n = D, T, Q) basis sets are chosen for C and Y atoms, respectively. The calculated geometry parameters of YC2 agree well with the corresponding experimental and previous theoretical results. The bonding characters of Ysbnd C2 or Csbnd C are discussed. Based on the optimized equilibrium geometries, the spectroscopic constants and anharmonic force field of YC2 are calculated. Comparing with the spectroscopic constants of YC2 derived from the experiment, the calculated results show that the B3PW91 and B3P86 methods are superior to B3LYP for YC2. The Coriolis coupling constants, cubic and quartic force constants of YC2 are reasonably predicted. Besides, the spectroscopic constants and anharmonic force field of Y13C2 (X˜2A1) and Y13CC (X˜2A‧) are calculated for the first time, which are expected to guide the high resolution experimental work for YC2 and its 13C isotopologues.

  13. DFT calculations for anharmonic force field and spectroscopic constants of YC2and its13C isotopologues.

    Science.gov (United States)

    Zhao, Yanliang; Wang, Meishan; Yang, Chuanlu; Ma, Xiaoguang; Li, Jing

    2018-02-15

    The construction of the complete third and the semi-diagonal quartic force fields including the anharmonicity of the ground state (X˜ 2 A 1 ) for yttrium dicarbide (YC 2 ) is carried out employing the vibrational second-order perturbation theory (VPT2) in combination with the density functional theory (DFT). The equilibrium geometries optimization, anharmonic force field and vibrational spectroscopic constants of YC 2 are calculated by B3LYP, B3PW91 and B3P86 methods. Aug-cc-pVnZ (n=D, T, Q) and cc-pVnZ-PP (n=D, T, Q) basis sets are chosen for C and Y atoms, respectively. The calculated geometry parameters of YC 2 agree well with the corresponding experimental and previous theoretical results. The bonding characters of YC 2 or CC are discussed. Based on the optimized equilibrium geometries, the spectroscopic constants and anharmonic force field of YC 2 are calculated. Comparing with the spectroscopic constants of YC 2 derived from the experiment, the calculated results show that the B3PW91 and B3P86 methods are superior to B3LYP for YC 2 . The Coriolis coupling constants, cubic and quartic force constants of YC 2 are reasonably predicted. Besides, the spectroscopic constants and anharmonic force field of Y 13 C 2 (X˜ 2 A 1 ) and Y 13 CC (X˜ 2 A ' ) are calculated for the first time, which are expected to guide the high resolution experimental work for YC 2 and its 13 C isotopologues. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Competition of a spring force constant and a phonon energy renormalization in electrochemically doped semiconducting single walled carbon nanotubes

    Czech Academy of Sciences Publication Activity Database

    Kalbáč, Martin; Farhat, H.; Kavan, Ladislav; Kong, J.; Dresselhaus, M. S.

    2008-01-01

    Roč. 8, č. 10 (2008), s. 3532-3537 ISSN 1530-6984 R&D Projects: GA ČR GC203/07/J067; GA AV ČR IAA400400804 Institutional research plan: CEZ:AV0Z40400503 Keywords : spring force constant * electrochemistry * carbon nanotube Subject RIV: CG - Electrochemistry Impact factor: 10.371, year: 2008

  15. Acute effects of unilateral static stretching on handgrip strength of the stretched and non-stretched limb.

    Science.gov (United States)

    Jelmini, Jacob D; Cornwell, Andrew; Khodiguian, Nazareth; Thayer, Jennifer; Araujo, And John

    2018-02-16

    To determine the effects of an acute bout of unilateral static stretching on handgrip strength of both the stretched and non-stretched limb. It was reasoned that if the non-stretched limb experienced a decrease in force output, further evidence for a neural mechanism to explain a post-stretch force reduction would be obtained as no mechanical adaptation would have occurred. Thirty participants performed maximum voluntary unilateral handgrip contractions of both limbs before and after stretching the finger flexors of the strength-dominant side only. Each trial was assessed for peak force, muscle activity (iEMG), and rate of force generation. Following the stretching bout, peak force and iEMG decreased by 4.4% (p = 0.001) and 6.4% (p = 0.000) respectively in the stretched limb only. However, rate of force generation was significantly impaired in both the stretched (- 17.3%; p = 0.000) and non-stretched limbs (- 10.8%; p = 0.003) 1 min post-stretch, and remained similarly depressed for both limbs 15 min later. Acute stretching negatively impacts rate of force generation more than peak force. Moreover, a reduced rate of force generation from the non-stretched limb indicates the presence of a cross-over inhibitory effect through the nervous system, which provides additional evidence for a neural mechanism.

  16. Towards quantitative determination of the spring constant of a scanning force microscope cantilever with a microelectromechanical nano-force actuator

    International Nuclear Information System (INIS)

    Gao, Sai; Herrmann, Konrad; Zhang, Zhikai; Wu, Yong

    2010-01-01

    The calibration of the performance of an SFM (scanning force microscope) cantilever has gained more and more interest in the past years, particularly due to increasing applications of SFMs for the determination of the mechanical properties of materials, such as biological structures and organic molecules. In this paper, a MEMS-based nano-force actuator with a force resolution up to nN (10 −9 N) is presented to quantitatively determine the stiffness of an SFM cantilever. The principle, structure design and realization of the nano-force actuator are detailed. Preliminary experiments demonstrate that the long-term self-calibration stability of the actuator is better than 3.7 × 10 −3 N m −1 (1σ) over 1 h. With careful calibration of the stiffness of the actuator, the MEMS actuator has the capability to determine the stiffness of various types of cantilevers (from 100 N m −1 down to 0.1 N m −1 ) with high accuracy. In addition, thanks to the large displacement and force range (up to 8 µm and 1 mN, respectively) of the actuator, the calibration procedure with our MEMS nano-force actuator features simple and active operation, and therefore applicability for different types of quantitative SFMs

  17. Phonon dispersion relations of Sb2S3 and Bi2S3 using the supercell force-constant method

    Science.gov (United States)

    Gan, Chee Kwan; Chua, Kun Ting Eddie; Liu, Yun

    2015-03-01

    We present a lattice dynamical study on the orthorhombic antimony sulphide (Sb2S3) and bismuth sulphide (Bi2S3) using the supercell force-constant method. We find that the slow decay of the interatomic force constants for these compounds in the Pnma setting critically demand the use of a large supercell of 2 × 4 × 2 that consists of 320 atoms. To enable a practical calculation the space group information is fully utilized where only inequivalent atoms within the primitive cell are displaced for the force calculations. The effect of Born effective charges is incorporated into the method. We compare our results with that obtained from the density-functional perturbation theory. We found that smaller supercells could lead to unphysical acoustic phonon softening and lifting of the degeneracies along high symmetry directions. Our results provide a proper guideline for the use of the supercell force-constant method: the supercell size must be carefully be tested along with other parameters such as the kinetic energy cutoff, the Brillouin zone sampling or the self-consistent convergence criteria.

  18. Calibration of the effective spring constant of ultra-short cantilevers for a high-speed atomic force microscope

    International Nuclear Information System (INIS)

    Song, Yun-Peng; Wu, Sen; Xu, Lin-Yan; Zhang, Jun-Ming; Fu, Xing; Hu, Xiao-Dong; Dorantes-Gonzalez, Dante J

    2015-01-01

    Ultra-short cantilevers are a new type of cantilever designed for the next generation of high-speed atomic force microscope (HS-AFM). Ultra-short cantilevers have smaller dimensions and higher resonant frequency than conventional AFM cantilevers. Moreover, their geometry may also be different from the conventional beam-shape or V-shape. These changes increase the difficulty of determining the spring constant for ultra-short cantilevers, and hence limit the accuracy and precision of force measurement based on a HS-AFM. This paper presents an experimental method to calibrate the effective spring constant of ultra-short cantilevers. By using a home-made AFM head, the cantilever is bent against an electromagnetic compensation balance under servo control. Meanwhile the bending force and the cantilever deflection are synchronously measured by the balance and the optical lever in the AFM head, respectively. Then the effective spring constant is simply determined as the ratio of the force to the corresponding deflection. Four ultra-short trapezoid shape cantilevers were calibrated using this method. A quantitative uncertainty analysis showed that the combined relative standard uncertainty of the calibration result is less than 2%, which is better than the uncertainty of any previously reported techniques. (paper)

  19. Stretching to understand proteins - a survey of the protein data bank.

    Science.gov (United States)

    Sułkowska, Joanna I; Cieplak, Marek

    2008-01-01

    We make a survey of resistance of 7510 proteins to mechanical stretching at constant speed as studied within a coarse-grained molecular dynamics model. We correlate the maximum force of resistance with the native structure, predict proteins which should be especially strong, and identify the nature of their force clamps.

  20. Rigid-layer Raman-active modes in N -layer transition metal dichalcogenides: interlayer force constants and hyperspectral Raman imaging

    Science.gov (United States)

    Froehlicher, Guillaume; Lorchat, Etienne; Zill, Olivia; Romeo, Michelangelo; Berciaud, Stéphane

    2018-01-01

    We report a comparative study of rigid layer Raman-active modes in $N$-layer transition metal dichalcogenides. Trigonal prismatic (2Hc, such as MoSe$_2$, MoTe$_2$, WS$_2$, WSe$_2$) and distorted octahedral (1T', such as ReS$_2$ and ReSe$_2$) phases are considered. The Raman-active in-plane interlayer shear modes and out-of-plane interlayer breathing modes appear as well-defined features with wavenumbers in the range 0-40~cm$^{-1}$. These rigid layer modes are well-described by an elementary linear chain model from which the interlayer force constants are readily extracted. Remarkably, these force constants are all found to be of the same order of magnitude. Finally, we show that the prominent interlayer shear and breathing mode features allow high-precision hyperspectral Raman imaging of $N-$layer domains within a given transition metal dichalcogenide flake.

  1. Study of the stretching force of the needle‧s thread in the work with woollen textiles

    Science.gov (United States)

    Andonova, Snezhina; Rahnev, Ivelin

    2017-10-01

    The presented paper deals with examining the thread tension force while working with woolen textile materials. The thread’s tension force is a main characteristic of a quality stitch. Its analysis and definition is characterized by the creation of a computer-integrated measuring system to determine the thread’s tension force. A statistical method (double-factor disperse analysis) is used to analyze and evaluate the fact how the factors: • F1 - surface mass of processed woolen textile materials, • F2 -the number of layers on the thread‧s influence the deviation from the maximal value of the thread’s tension force.

  2. The constant beat: cardiomyocytes adapt their forces by equal contraction upon environmental stiffening

    Directory of Open Access Journals (Sweden)

    Nils Hersch

    2013-01-01

    Cardiomyocytes are responsible for the permanent blood flow by coordinated heart contractions. This vital function is accomplished over a long period of time with almost the same performance, although heart properties, as its elasticity, change drastically upon aging or as a result of diseases like myocardial infarction. In this paper we have analyzed late rat embryonic heart muscle cells' morphology, sarcomere/costamere formation and force generation patterns on substrates of various elasticities ranging from ∼1 to 500 kPa, which covers physiological and pathological heart stiffnesses. Furthermore, adhesion behaviour, as well as single myofibril/sarcomere contraction patterns, was characterized with high spatial resolution in the range of physiological stiffnesses (15 kPa to 90 kPa. Here, sarcomere units generate an almost stable contraction of ∼4%. On stiffened substrates the contraction amplitude remains stable, which in turn leads to increased force levels allowing cells to adapt almost instantaneously to changing environmental stiffness. Furthermore, our data strongly indicate specific adhesion to flat substrates via both costameric and focal adhesions. The general appearance of the contractile and adhesion apparatus remains almost unaffected by substrate stiffness.

  3. Do the NiTi low and constant force levels remain stable in vivo?

    Science.gov (United States)

    Sarul, Michał; Kawala, Beata; Kawala, Maciej; Antoszewska-Smith, Joanna

    2015-12-01

    The aim was to evaluate the alteration of the deactivation forces of the most commonly used nickel-titanium wires under long-lasting oral cavity environmental influence. Randomized in vitro and in vivo trials of 540 pieces of orthodontic archwires, NeoSentalloy®, Copper NiTi® 35°C and Titanol Superelastic(®), round (0.016 inch), and rectangular (0.016 × 0.022 inch), were carried out. Randomization and blinding was achieved with 12-colour system that ensured encoding of key information on the tested specimens. Each of 270 patients (females, 18-20 years old, in the finishing stage of orthodontic treatment) received the piece of NiTi wire ligated piggyback, for a period of 4-6 weeks. Eventually, all samples were subjected to a three-point bending test. Data were statistically analysed at a 5 per cent significance level. In the group of the round used wires, when compared with the new ones, the deactivation force (F dav) values increased significantly for Titanol Superelastic®; the NeoSentalloy® and Copper NiTi® 35°C wires did not change their values of F dav. In the group of rectangular wires, F dav decreased for Titanol Superelastic®, but increased for NeoSentalloy® wires. The F dav values of the Copper NiTi® 35°C used wires practically did not change, but a remarkable increase of the standard deviation was noted. No calculations concerning effectiveness of in vivo aligning of analysed wires were made. For the purpose of a 4-6-week aligning stage, round NeoSentalloy® with a diameter of 0.016 inches seems to be the wire of choice because of the low level of F dav. © The Author 2015. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  4. Developing combined free and forced laminar convection between vertical parallel plates with constant wall temperature

    International Nuclear Information System (INIS)

    Nakajima, Masamoto; Fukui, Keisuke; Ueda, Hiromasa; Mizushina, Tokuro

    1978-01-01

    A theoretical study is presented on the transfer problem subject to developing flow of mixed convection between vertical parallel plates. Present analysis aims to make clear the transfer mechanism for aiding and opposing flow, based upon and developing Leveque's solution. Average mass transfer measurements were obtained for both aiding and opposing flow in a vertical annulus by using the electrochemical method, i.e. the reduction of ferricyanide at the cathode in a solution of K 4 Fe(CN) 6 -K 3 Fe(CN) 6 -NaOH. Both theoretical and experimental results show that the parameter Gr sub(h)/Re sub(h) is able to express the effect of the buoyancy force in aiding and opposing flows. With increasing Gr sub(h)/Re sub(h) in the case of aiding flow, Nusselt numbers increase, being proportional to (Re sub(h)PrD sub(h)/L)sup(n), and the exponent n decreases. As to opposing flow, the buoyancy effect is more remarkable than in the case of aiding flow. It reduces the velocity in the thermal-boundary layer and promotes rapid transition to turbulent state owing to flow instability. (auth.)

  5. Potential constants of CF4

    International Nuclear Information System (INIS)

    Jones, L.H.; Kennedy, C.; Ekberg, S.

    1978-01-01

    The infrared spectra of the 12 C, 13 C, and 14 C isotopic species of CF 4 have been observed at a resolution of 0.06 cm -1 . In addition to the fundamentals ν 3 and ν 4 a number of combination bands have been observed. Using these results, combined with Raman data in the literature, we have calculated the quadratic valence force field, in terms of force constants as well as compliance constants, with considerably better precision than previously obtained. Interaction displacement coordinates have been calculated and show that stretching one CF bond leads, for minimum energy near equilibrium, to opening up of the angles between the other three bonds as well as to their contraction

  6. Both the elongation of attached crossbridges and residual force enhancement contribute to joint torque enhancement by the stretch-shortening cycle

    Science.gov (United States)

    Misaki, Jun; Isaka, Tadao

    2017-01-01

    This study examined the influence of the elongation of attached crossbridges and residual force enhancement on joint torque enhancement by the stretch-shortening cycle (SSC). Electrically evoked submaximal tetanic plantar flexions were adopted. Concentric contractions were evoked in the following three conditions: after 2 s isometric preactivation (ISO condition), after 1 s isometric then 1 s eccentric preactivation (ECC condition), and after 1 s eccentric then 1 s isometric preactivation (TRAN condition). Joint torque and fascicle length were measured during the concentric contraction phase. While no differences in fascicle length were observed among conditions at any time points, joint torque was significantly higher in the ECC than TRAN condition at the onset of concentric contraction. This difference would be caused by the dissipation of the elastic energy stored in the attached crossbridges induced by eccentric preactivation in TRAN condition due to 1 s transition phase. Furthermore, joint torques observed 0.3 and 0.6 s after concentric contraction were significantly larger in the ECC and TRAN conditions than in the ISO condition while no difference was observed between the ECC and TRAN conditions. Since the elastic energy stored in the attached crossbridges would have dissipated over this time frame, this result suggests that residual force enhancement induced by eccentric preactivation also contributes to joint torque enhancement by the SSC. PMID:28386453

  7. Adapting the Euler–Lagrange equation to study one-dimensional motions under the action of a constant force

    Science.gov (United States)

    Dias, Clenilda F.; Araújo, Maria A. S.; Carvalho-Santos, Vagson L.

    2018-01-01

    The Euler–Lagrange equations (ELE) are very important in the theoretical description of several physical systems. In this work we have used a simplified form of ELE to study one-dimensional motions under the action of a constant force. From the use of the definition of partial derivative, we have proposed two operators, here called mean delta operators, which may be used to solve the ELE in a simplest way. We have applied this simplification to solve three simple mechanical problems in which the particle is under the action of the gravitational field: a free fall body, the Atwood’s machine and the inclined plan. The proposed simplification can be used to introduce the lagrangian formalism in teaching classical mechanics in introductory physics courses.

  8. Increase in twitch force of the adductor pollicis muscle with stabilized preload at constant thumb abduction before and after administration of muscle relaxant

    NARCIS (Netherlands)

    van Santen, G; Wierda, JMKH; Fidler, [No Value

    Objective. To determine whether the twitch force of the adductor pollicis remains stable when 0.1 Hz single twitch stimulation is started after stabilization of the thumb preload at a constant degree of thumb abduction; also to study any possible increase in twitch force before the onset of and

  9. Influence of Lorentz force, Cattaneo-Christov heat flux and viscous dissipation on the flow of micropolar fluid past a nonlinear convective stretching vertical surface

    Science.gov (United States)

    Gnaneswara Reddy, Machireddy

    2017-12-01

    The problem of micropolar fluid flow over a nonlinear stretching convective vertical surface in the presence of Lorentz force and viscous dissipation is investigated. Due to the nature of heat transfer in the flow past vertical surface, Cattaneo-Christov heat flux model effect is properly accommodated in the energy equation. The governing partial differential equations for the flow and heat transfer are converted into a set of ordinary differential equations by employing the acceptable similarity transformations. Runge-Kutta and Newton's methods are utilized to resolve the altered governing nonlinear equations. Obtained numerical results are compared with the available literature and found to be an excellent agreement. The impacts of dimensionless governing flow pertinent parameters on velocity, micropolar velocity and temperature profiles are presented graphically for two cases (linear and nonlinear) and analyzed in detail. Further, the variations of skin friction coefficient and local Nusselt number are reported with the aid of plots for the sundry flow parameters. The temperature and the related boundary enhances enhances with the boosting values of M. It is found that fluid temperature declines for larger thermal relaxation parameter. Also, it is revealed that the Nusselt number declines for the hike values of Bi.

  10. Numerical Study of Laminar Flow Forced Convection of Water-Al2O3 Nanofluids under Constant Wall Temperature Condition

    Directory of Open Access Journals (Sweden)

    Hsien-Hung Ting

    2015-01-01

    Full Text Available This numerical study is aimed at investigating the forced convection heat transfer and flow characteristics of water-based Al2O3 nanofluids inside a horizontal circular tube in the laminar flow regime under the constant wall temperature boundary condition. Five volume concentrations of nanoparticle, 0.1, 0.5, 1, 1.5, and 2 vol.%, are used and diameter of nanoparticle is 40 nm. Characteristics of heat transfer coefficient, Nusselt number, and pressure drop are reported. The results show that heat transfer coefficient of nanofluids increases with increasing Reynolds number or particle volume concentration. The heat transfer coefficient of the water-based nanofluid with 2 vol.% Al2O3 nanoparticles is enhanced by 32% compared with that of pure water. Increasing particle volume concentration causes an increase in pressure drop. At 2 vol.% of particle concentration, the pressure drop reaches a maximum that is nearly 5.7 times compared with that of pure water. It is important to note that the numerical results are in good agreement with published experimental data.

  11. Activation enthalpy of self-diffusion in pure metals interpreted as a measure of their interatomic force constant

    International Nuclear Information System (INIS)

    Turkdogan, E.T.

    2002-01-01

    The present study of self-diffusion data for pure solid elements has revealed that the diffusivities of body centered cubic (b.c.c.), face centered cubic (f.c.c.) and hexagonal close packed (h.c.p.) metals at their melting point temperatures (T m ) do relate in a systematic manner to the atomic number of the elements and their Period numbers. Also, the activation enthalpy of self-diffusion varies in a regular manner with the atomic number and Period number of the elements. It is surmised from these regularities that the activation enthalpy (Q) of self-diffusion may be considered as a direct measure of the interatomic force constant ε/k = (φ/R)T m where φ = Q/T m is the enthalpy coefficient. For solid metals ε/k = (15 to 19) T m , K; for non-metals the T m coefficient is (20 to 35), for rare-earth metals (10 to 13) and for liquid metals (3.32 ± 0.24). A comparison is made of these ε/k values with those derived from the standard enthalpies of dissociation of inorganic compounds to the constituent elements. A critical assessment is made of the experimental self-diffusion data for pure elements which conform to the observed regularities in the self-diffusion parameters in relation to the atomic number and Period number of the elements. (author)

  12. The maximum penalty criterion for ridge regression: application to the calibration of the force constant in elastic network models.

    Science.gov (United States)

    Dehouck, Yves; Bastolla, Ugo

    2017-07-17

    Tikhonov regularization, or ridge regression, is a popular technique to deal with collinearity in multivariate regression. We unveil a formal analogy between ridge regression and statistical mechanics, where the objective function is comparable to a free energy, and the ridge parameter plays the role of temperature. This analogy suggests two novel criteria for selecting a suitable ridge parameter: specific-heat (C v ) and maximum penalty (MP). We apply these fits to evaluate the relative contributions of rigid-body and internal fluctuations, which are typically highly collinear, to crystallographic B-factors. This issue is particularly important for computational models of protein dynamics, such as the elastic network model (ENM), since the amplitude of the predicted internal motion is commonly calibrated using B-factor data. After validation on simulated datasets, our results indicate that rigid-body motions account on average for more than 80% of the amplitude of B-factors. Furthermore, we evaluate the ability of different fits to reproduce the amplitudes of internal fluctuations in X-ray ensembles from the B-factors in the corresponding single X-ray structures. The new ridge criteria are shown to be markedly superior to the commonly used two-parameter fit that neglects rigid-body rotations and to the full fits regularized under generalized cross-validation. In conclusion, the proposed fits ensure a more robust calibration of the ENM force constant and should prove valuable in other applications.

  13. An energetic model for macromolecules unfolding in stretching experiments

    Science.gov (United States)

    De Tommasi, D.; Millardi, N.; Puglisi, G.; Saccomandi, G.

    2013-01-01

    We propose a simple approach, based on the minimization of the total (entropic plus unfolding) energy of a two-state system, to describe the unfolding of multi-domain macromolecules (proteins, silks, polysaccharides, nanopolymers). The model is fully analytical and enlightens the role of the different energetic components regulating the unfolding evolution. As an explicit example, we compare the analytical results with a titin atomic force microscopy stretch-induced unfolding experiment showing the ability of the model to quantitatively reproduce the experimental behaviour. In the thermodynamic limit, the sawtooth force–elongation unfolding curve degenerates to a constant force unfolding plateau. PMID:24047874

  14. Developing a Stretching Program.

    Science.gov (United States)

    Beaulieu, J E

    1981-11-01

    In brief: Although stretching exercises can prevent muscle injuries and enhance athletic performance, they can also cause injury. The author explains the four most common types of stretching exercises and explains why he considers static stretching the safest. He also sets up a stretching routine for runners. In setting up a safe stretching program, one should (1) precede stretching exercises with a mild warm-up; (2) use static stretching; (3) stretch before and after a workout; (4) begin with mild and proceed to moderate exercises; (5) alternate exercises for muscle groups; (6) stretch gently and slowly until tightness, not pain, is felt; and (7) hold the position for 30 to 60 seconds.

  15. Stretch Sensor Device

    DEFF Research Database (Denmark)

    2013-01-01

    The invention relates to a method for determining stretch values and movement of body parts, e.g. a foot, by analysing stretch data from a stretch sensor. By analysing data from the stretch sensor it is possible to determine stretch samples which are associated with particular motion phases...

  16. The apparent rate constant for the dissociation of force generating myosin crossbridges from actin decreases during Ca2+ activation of skinned muscle fibres.

    Science.gov (United States)

    Kerrick, W G; Potter, J D; Hoar, P E

    1991-02-01

    The effect of Ca2+ activation on the apparent rate constant governing the dissociation of force generating myosin crossbridges was studied in skinned rabbit adductor magnus fibres (fast-twitch) at 21 +/- 1 degree C. Simultaneous measurements of Ca2(+)-activated isometric force and ATPase activity were conducted in parallel with simultaneous measurements of DANZ-labelled troponin C (TnCDANZ) fluorescence and isometric force in fibres whose endogenous troponin C had been partially replaced with TnCDANZ. The Ca2+ activation of isometric force occurred at approximately two times higher Ca2+ concentration than did actomyosin ATPase activity at 2.0 mM MgATP. Since increases in both TnCDANZ fluorescence and ATPase activity occurred over approximately the same Ca2+ concentration range at substantially lower concentrations of Ca2+ than did force, this data suggests that the TnCDANZ fluorescence is associated with the Ca2+ activation of myosin crossbridge turnover (ATPase) rather than force. According to the model of Huxley (1957) and assuming the hydrolysis of one molecule of ATP per cycle of the crossbridge, the apparent rate constant gapp for the dissociation of force generating myosin crossbridges is proportional to the actomyosin ATPase/isometric force ratio. This measure of gapp shows approximately a fivefold decrease during Ca2+ activation of isometric force. This change in gapp is responsible for separation of the Ca2+ sensitivity of the normalized ATPase activity and isometric force curves. If the MgATP concentration is reduced to 0.5 mM, the change in gapp is reduced and consequently the difference in Ca2+ sensitivity between normalized steady state ATPase and force is also reduced.

  17. Force Field Benchmark of Organic Liquids: Density, Enthalpy of Vaporization, Heat Capacities, Surface Tension, Isothermal Compressibility, Volumetric Expansion Coefficient, and Dielectric Constant.

    Science.gov (United States)

    Caleman, Carl; van Maaren, Paul J; Hong, Minyan; Hub, Jochen S; Costa, Luciano T; van der Spoel, David

    2012-01-10

    The chemical composition of small organic molecules is often very similar to amino acid side chains or the bases in nucleic acids, and hence there is no a priori reason why a molecular mechanics force field could not describe both organic liquids and biomolecules with a single parameter set. Here, we devise a benchmark for force fields in order to test the ability of existing force fields to reproduce some key properties of organic liquids, namely, the density, enthalpy of vaporization, the surface tension, the heat capacity at constant volume and pressure, the isothermal compressibility, the volumetric expansion coefficient, and the static dielectric constant. Well over 1200 experimental measurements were used for comparison to the simulations of 146 organic liquids. Novel polynomial interpolations of the dielectric constant (32 molecules), heat capacity at constant pressure (three molecules), and the isothermal compressibility (53 molecules) as a function of the temperature have been made, based on experimental data, in order to be able to compare simulation results to them. To compute the heat capacities, we applied the two phase thermodynamics method (Lin et al. J. Chem. Phys.2003, 119, 11792), which allows one to compute thermodynamic properties on the basis of the density of states as derived from the velocity autocorrelation function. The method is implemented in a new utility within the GROMACS molecular simulation package, named g_dos, and a detailed exposé of the underlying equations is presented. The purpose of this work is to establish the state of the art of two popular force fields, OPLS/AA (all-atom optimized potential for liquid simulation) and GAFF (generalized Amber force field), to find common bottlenecks, i.e., particularly difficult molecules, and to serve as a reference point for future force field development. To make for a fair playing field, all molecules were evaluated with the same parameter settings, such as thermostats and barostats

  18. Effect of the ion force on the hydrolysis constants and of the solubility product of Europium; Efecto de la fuerza ionica sobre las constantes de hidrolisis y del producto de solubilidad del europio

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez R, M.; Ramirez G, J.J.; Solache R, M.; Rojas H, A. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2003-07-01

    A study on the behavior of the first hydrolysis constant {beta}{sub Eu,H}{sup l-0} and the constant of the solubility product Kps of the europium in front of the changes of the ion force: 0. 02 M, 0.1 M, 0.7M, 2M, 3M and 4M of sodium perchlorate, at 303 K. Experimentally the potentiometry and also radioactivity measures its were used. The specific interaction of ions theory (SIT) of Bronsted-Guggenheim-Scatchard allows the extrapolation of the values to infinite dilution and the results were: log {beta}{sub Eu,H}{sup l-0} = -7 36 and log K{sub sp}{sup l-0} = -24. 68. A discussion of the group of results with the data of the literature is presented. (Author)

  19. Effect of the ion force on the stability constants of the complexes LnCl2+ and LnCl2+ of Europium and Lutetium

    International Nuclear Information System (INIS)

    Fernandez R, E.; Jimenez R, M.; Solache R, M.

    2004-01-01

    A study is presented on the determination of the constants of stability of those complex LnCI 3-n n (where Ln = Eu 3+ and Lu 3+ and n = 1 and 2), by means of a method of extraction with solvent, to constant temperature (303 K) and in means of high ionic force (1- 3M H CI/HCIO 4 ). It is also presented the application of the theory of the specific interaction of ions (SIT) of Bronsted-Guggenheim-Scatchard for the extrapolation of the values to infinite dilution. (Author)

  20. Isoforce: A new outrigger system for static progressive orthotic interventions of the proximal interphalangeal joint with constant force transmission-Results of a biomechanical study.

    Science.gov (United States)

    Marrel, Marion; Jörn Good, Ulla; Marks, Miriam; Herren, Daniel B; Goldhahn, Jörg

    Bench research-biomechanical study. Static progressive orthotic devices are efficient in treating contractures. However, current outriggers are unable to keep force transmission and the force application angle (FAA) constant. To evaluate the biomechanical performance of the Isoforce outrigger, a novel extension orthosis. A hand model was used to measure the required force at the outrigger and FAA, while simulating resolution of different contracture angles. We also tested feasibility in a small patient series. The force required with the Isoforce device never exceeded 2.4 N, and the FAA did not change more than 6°. Corresponding figures for the reference devices exceeded 16 N and 20°. The 7 patients testing the Isoforce extension device showed an extension deficit that decreased from 40° at baseline to 25° at 6 weeks. They rated the device as very comfortable to wear. Isoforce maintains constant force transmission and FAA throughout the full range of motion, promotes the lengthening of contracted structures, and is comfortable to wear. Not applicable. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  1. Excluded Volume Effects in Gene Stretching

    OpenAIRE

    Lam, Pui-Man

    2002-01-01

    We investigate the effects excluded volume on the stretching of a single DNA in solution. We find that for small force F, the extension h is not linear in F but proportion to F^{\\chi}, with \\chi=(1-\

  2. Exact Green's function method of solar force-free magnetic-field computations with constant alpha. I - Theory and basic test cases

    Science.gov (United States)

    Chiu, Y. T.; Hilton, H. H.

    1977-01-01

    Exact closed-form solutions to the solar force-free magnetic-field boundary-value problem are obtained for constant alpha in Cartesian geometry by a Green's function approach. The uniqueness of the physical problem is discussed. Application of the exact results to practical solar magnetic-field calculations is free of series truncation errors and is at least as economical as the approximate methods currently in use. Results of some test cases are presented.

  3. Anisotropic instability of a stretching film

    Science.gov (United States)

    Xu, Bingrui; Li, Minhao; Deng, Daosheng

    2017-11-01

    Instability of a thin liquid film, such as dewetting arising from Van der Waals force, has been well studied, and is typically characterized by formation of many droplets. Interestingly, a thin liquid film subjected to an applied stretching during a process of thermal drawing is evolved into an array of filaments, i.e., continuity is preserved along the direction of stretching while breakup occurs exclusively in the plane of cross section. Here, to understand this anisotropic instability, we build a physical model by considering both Van der Waals force and the effect of stretching. By using the linear instability analysis method and then performing a numerical calculation, we find that the growth rate of perturbations at the cross section is larger than that along the direction of stretching, resulting in the anisotropic instability of the stretching film. These results may provide theoretical guidance to achieve more diverse structures for nanotechnology.

  4. Metabolic costs of force generation for constant-frequency and catchlike-inducing electrical stimulation in human tibialis anterior muscle

    DEFF Research Database (Denmark)

    Ratkevicius, Aivaras; Quistorff, Bjørn

    2002-01-01

    at 37.5 ms. One train was delivered to the peroneal nerve every 2.5 s for 36 times under ischemic conditions. Anaerobic adenosine triphosphate (ATP) turnover was determined using 31-phosphorus magnetic resonance spectroscopy (P-MRS) of the human tibialis anterior muscle. Compared with constant...

  5. Toward Automated Benchmarking of Atomistic Force Fields: Neat Liquid Densities and Static Dielectric Constants from the ThermoML Data Archive.

    Science.gov (United States)

    Beauchamp, Kyle A; Behr, Julie M; Rustenburg, Ariën S; Bayly, Christopher I; Kroenlein, Kenneth; Chodera, John D

    2015-10-08

    Atomistic molecular simulations are a powerful way to make quantitative predictions, but the accuracy of these predictions depends entirely on the quality of the force field employed. Although experimental measurements of fundamental physical properties offer a straightforward approach for evaluating force field quality, the bulk of this information has been tied up in formats that are not machine-readable. Compiling benchmark data sets of physical properties from non-machine-readable sources requires substantial human effort and is prone to the accumulation of human errors, hindering the development of reproducible benchmarks of force-field accuracy. Here, we examine the feasibility of benchmarking atomistic force fields against the NIST ThermoML data archive of physicochemical measurements, which aggregates thousands of experimental measurements in a portable, machine-readable, self-annotating IUPAC-standard format. As a proof of concept, we present a detailed benchmark of the generalized Amber small-molecule force field (GAFF) using the AM1-BCC charge model against experimental measurements (specifically, bulk liquid densities and static dielectric constants at ambient pressure) automatically extracted from the archive and discuss the extent of data available for use in larger scale (or continuously performed) benchmarks. The results of even this limited initial benchmark highlight a general problem with fixed-charge force fields in the representation low-dielectric environments, such as those seen in binding cavities or biological membranes.

  6. Hamstring Stiffness Returns More Rapidly After Static Stretching Than Range of Motion, Stretch Tolerance, and Isometric Peak Torque.

    Science.gov (United States)

    Hatano, Genki; Suzuki, Shigeyuki; Matsuo, Shingo; Kataura, Satoshi; Yokoi, Kazuaki; Fukaya, Taizan; Fujiwara, Mitsuhiro; Asai, Yuji; Iwata, Masahiro

    2017-12-18

    Hamstring injuries are common, and lack of hamstring flexibility may predispose to injury. Static stretching increases range of motion (ROM) but also results in reduced muscle strength after stretching. The effects of stretching on the hamstring muscles and the duration of these effects remain unclear. To determine the effects of static stretching on the hamstrings and the duration of these effects. Randomized crossover study. University laboratory. Twenty-four healthy volunteers. We measured the torque-angle relationship (ROM, passive torque (PT) at the onset of pain, and passive stiffness) and isometric muscle force using an isokinetic dynamometer. After a 60-minute rest, the ROM of the dynamometer was set at maximum tolerable intensity; this position was maintained for 300 seconds while static passive torque (SPT) was measured continuously. We remeasured the torque-angle relationship and isometric muscle force after rest periods of 10, 20, and 30 minutes. Change in SPT during stretching; changes in ROM, PT at the onset of pain, passive stiffness, and isometric muscle force before stretching compared with 10, 20, and 30 minutes after stretching. SPT decreased significantly during stretching. Passive stiffness decreased significantly 10 and 20 minutes after stretching, but there was no significant pre- vs. post-stretching difference after 30 minutes. PT at the onset of pain and ROM increased significantly after stretching at all rest intervals, while isometric muscle force decreased significantly after all rest intervals. The effect of static stretching on passive stiffness of the hamstrings was not maintained as long as the changes in ROM, stretch tolerance, and isometric muscle force. Therefore, frequent stretching is necessary to improve the viscoelasticity of the muscle-tendon unit. Muscle force was decreased for 30 minutes after stretching; this should be considered prior to activities requiring maximal muscle strength.

  7. Microelectromechanical system device for calibration of atomic force microscope cantilever spring constants between 0.01 and 4 N/m

    International Nuclear Information System (INIS)

    Cumpson, Peter J.; Hedley, John; Clifford, Charles A.; Chen Xinyong; Allen, Stephanie

    2004-01-01

    Calibration of atomic force microscope (AFM) cantilevers is necessary for the measurement of nano-newton and pico-newton forces, which are critical to analytical application of AFM in the analysis of polymer surfaces, biological structures and organic molecules. Previously we have described microfabricated array of reference spring (MARS) devices for AFM cantilever spring-constant calibration. Hitherto, these have been limited to the calibration of AFM cantilevers above 0.03 N/m, although they can be used to calibrate cantilevers of lower stiffness with reduced accuracy. Below this limit MARS devices similar to the designs hitherto described would be fragile and difficult to manufacture with reasonable yield. In this work we describe a device we call torsional MARS. This is a large-area torsional mechanical resonator, manufactured by bulk micromachining of a 'silicon-on-insulator' wafer. By measuring its torsional oscillation accurately in vacuum we can deduce its torsional spring constant. The torsional reference spring spans the range of spring constant (from 4 down to 0.01 N/m) that is important in biological AFM, allowing even the most compliant AFM cantilever to be calibrated easily and rapidly

  8. Stretching Safely and Effectively

    Science.gov (United States)

    ... of stretching before or after hitting the trail, ballet floor or soccer field. Before you plunge into ... ballistic stretching on strength and muscular fatigue of ballet dancers and resistance-trained women. Journal of Strength ...

  9. Force Field Benchmark of the TraPPE_UA for Polar Liquids: Density, Heat of Vaporization, Dielectric Constant, Surface Tension, Volumetric Expansion Coefficient, and Isothermal Compressibility.

    Science.gov (United States)

    Núñez-Rojas, Edgar; Aguilar-Pineda, Jorge Alberto; Pérez de la Luz, Alexander; de Jesús González, Edith Nadir; Alejandre, José

    2018-02-08

    The transferable potential for a phase equilibria force field in its united-atom version, TraPPE_UA, is evaluated for 41 polar liquids that include alcohols, thiols, ethers, sulfides, aldehydes, ketones, and esters to determine its ability to reproduce experimental properties that were not included in the parametrization procedure. The intermolecular force field parameters for pure components were fit to reproduce experimental boiling temperature, vapor-liquid coexisting densities, and critical point (temperature, density, and pressure) using Monte Carlo simulations in different ensembles. The properties calculated in this work are liquid density, heat of vaporization, dielectric constant, surface tension, volumetric expansion coefficient, and isothermal compressibility. Molecular dynamics simulations were performed in the gas and liquid phases, and also at the liquid-vapor interface. We found that relative error between calculated and experimental data is 1.2% for density, 6% for heat of vaporization, and 6.2% for surface tension, in good agreement with the experimental data. The dielectric constant is systematically underestimated, and the relative error is 37%. Evaluating the performance of the force field to reproduce the volumetric expansion coefficient and isothermal compressibility requires more experimental data.

  10. Relationship of the vibrational frequency of the nuclear pair Mo-Cl with it electronegativity, force constant and bond length in the structural conformation of molybden dichloride

    International Nuclear Information System (INIS)

    Rodriguez S, A.; Martinez Q, E.

    1990-08-01

    The structural elucidation of the cluster hexamerico (MO 6 C1 8 ) 4+ , it has been characterized for but of twenty-five years like a conformation octahedrica of simple metallic connections. However, the determination has not been attempted of some physical characteristics of this conformation by means of measures espectroscopicas. We present the electronegatividad measures now, constant of force and it distances of connection of the nuclear couple Mo-Cl, using only their frequency vibracional taken directly of the infrared spectra. (Author)

  11. Measuring fN force variations in the presence of constant nN forces: a torsion pendulum ground test of the LISA Pathfinder free-fall mode

    Science.gov (United States)

    Russano, G.; Cavalleri, A.; Cesarini, A.; Dolesi, R.; Ferroni, V.; Gibert, F.; Giusteri, R.; Hueller, M.; Liu, L.; Pivato, P.; Tu, H. B.; Vetrugno, D.; Vitale, S.; Weber, W. J.

    2018-02-01

    LISA Pathfinder is a differential accelerometer with the main goal being to demonstrate the near perfect free-fall of reference test masses, as is needed for an orbiting gravitational wave observatory, with a target sensitivity of 30 fm s‑2 Hz-1/2 at 1 mHz. Any lasting background differential acceleration between the two test masses must be actively compensated, and noise associated with the applied actuation force can be a dominant source of noise. To remove this actuation, and the associated force noise, a ‘free-fall’ actuation control scheme has been designed; actuation is limited to brief impulses, with both test masses in free-fall in the time between the impulses, allowing measurement of the remaining acceleration noise sources. In this work, we present an on-ground torsion pendulum testing campaign of this technique and associated data analysis algorithms at a level nearing the sub-femto-g/\\sqrtHz performance required for LISA Pathfinder.

  12. DNA stretching on functionalized gold surfaces.

    OpenAIRE

    Zimmermann, R M; Cox, E C

    1994-01-01

    We describe a method for anchoring bacteriophage lambda DNA by one end to gold by Au-biotin-streptavidin-biotin-DNA bonds. DNA anchored to a microfabricated Au line could be aligned and stretched in flow and electric fields. The anchor was shown to resist a force of at least 11 pN, a linkage strong enough to allow DNA molecules of chromosome size to be stretched and aligned.

  13. Time and direction preparation of the long latency stretch reflex.

    Science.gov (United States)

    Nikaido, Yasutaka; Hatanaka, Ryota; Jono, Yasutomo; Nomura, Yoshifumi; Tani, Keisuke; Chujo, Yuta; Hiraoka, Koichi

    2016-06-01

    This study investigated time and direction preparation of motor response to force load while intending to maintain the finger at the initial neutral position. Force load extending or flexing the index finger was given while healthy humans intended to maintain the index finger at the initial neutral position. Electromyographic activity was recorded from the first dorsal interosseous muscle. A precue with or without advanced information regarding the direction of the forthcoming force load was given 1000ms before force load. Trials without the precue were inserted between the precued trials. A long latency stretch reflex was elicited by force load regardless of its direction, indicating that the long latency stretch reflex is elicited not only by muscle stretch afferents, but also by direction-insensitive sensations. Time preparation of motor response to either direction of force load enhanced the long latency stretch reflex, indicating that time preparation is not mediated by afferent discharge of muscle stretch. Direction preparation enhanced the long latency stretch reflex and increased corticospinal excitability 0-20ms after force load when force load was given in the direction stretching the muscle. These enhancements must be induced by preset of the afferent pathway mediating segmental stretch reflex. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Stretching a semiflexible polymer with orientation-dependent interactions

    International Nuclear Information System (INIS)

    Zhen Yi; Vilgis, Thomas A

    2009-01-01

    The mean field variational approach is employed to study the effect of a nematic field and an external constant force field on the elasticity of a semiflexible polymer. In the stationary phase, we obtain the force–extension relationship and calculate the hairpin density of a stretched semiflexible polymer in nematic solvents. The force–extension behavior is found to be controlled by the parameters gl p and gf where g is the strength of the nematic field, l p is the bare persistence length and f is the external force. Several distinct regimes for the elastic response and the hairpin density emerge depending on the value of gl p and gf. Qualitative comparisons between our computation and other theories are presented

  15. Determination of lutetium (III) hydrolysis constants in the middle of ion force 1M sodium chloride at 303 K; Determinacion de las constantes de hidrolisis del lutecio (III), en medio de fuerza ionica 1M de cloruro de sodio, a 303 K

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez R, M.; Solache R, M.J. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Ramirez G, J.J.; Rojas H, A. [Universidad Autonoma Metropolitana-Iztapalapa, Mexico D.F. (Mexico). Dept. de Quimica

    1997-07-01

    With the purpose to complete information about the lutetium (III) hydrolysis constants here is used the potentiometric method to determine those in the middle of ion force 1M sodium chloride at 303 K. (Author)

  16. Stretched Wire Mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Bowden, Gordon; /SLAC

    2005-09-06

    Stretched wires are beginning to play an important role in the alignment of accelerators and synchrotron light sources. Stretched wires are proposed for the alignment of the 130 meter long LCLS undulator. Wire position technology has reached sub-micron resolution yet analyses of perturbations to wire straightness are hard to find. This paper considers possible deviations of stretched wire from the simple 2-dimensional catenary form.

  17. The Exact Solutions for a Point Mass Moving along a Stretched String on a Winkler Foundation

    Directory of Open Access Journals (Sweden)

    Q. Gao

    2014-01-01

    Full Text Available This paper derives the exact solutions for a point mass moving along a stretched infinite string on a Winkler foundation at a constant velocity. The solutions for the contact force between the string and the mass are derived and then the displacement responses of the string can be obtained easily. The solutions cover infinite string subjected to a moving mass at subsonic, sonic, or supersonic velocities. When time tends to infinity, the asymptotical solutions for the contact force between the mass and the string and for the displacement of the contact point are derived. The formulas derived are shown to be correct by comparison with the semianalytical method.

  18. Dehydrogenation Kinetics and Modeling Studies of MgH2 Enhanced by Transition Metal Oxide Catalysts Using Constant Pressure Thermodynamic Driving Forces

    Directory of Open Access Journals (Sweden)

    Saidi Temitope Sabitu

    2012-06-01

    Full Text Available The influence of transition metal oxide catalysts (ZrO2, CeO2, Fe3O4 and Nb2O5 on the hydrogen desorption kinetics of MgH2 was investigated using constant pressure thermodynamic driving forces in which the ratio of the equilibrium plateau pressure (pm to the opposing plateau (pop was the same in all the reactions studied. The results showed Nb2O5 to be vastly superior to other catalysts for improving the thermodynamics and kinetics of MgH2. The modeling studies showed reaction at the phase boundary to be likely process controlling the reaction rates of all the systems studied.

  19. Vibrational Frequencies and Spectroscopic Constants for 1(sup 3)A' HNC and 1(sup 3)A' HOC+ from High-Accuracy Quartic Force Fields

    Science.gov (United States)

    Fortenberry, Ryan C.; Crawford, T. Daniel; Lee, Timothy J.

    2014-01-01

    The spectroscopic constants and vibrational frequencies for the 1(sup 3)A' states of HNC, DNC, HOC+, and DOC+ are computed and discussed in this work. The reliable CcCR quartic force field based on high-level coupled cluster ab initio quantum chemical computations is exclusively utilized to provide the anharmonic potential. Then, second order vibrational perturbation theory and vibrational configuration interaction methods are employed to treat the nuclear Schroedinger equation. Second-order perturbation theory is also employed to provide spectroscopic data for all molecules examined. The relationship between these molecules and the corresponding 1(sup 3)A' HCN and HCO+ isomers is further developed here. These data are applicable to laboratory studies involving formation of HNC and HOC+ as well as astronomical observations of chemically active astrophysical environments.

  20. Stretching: Does It Help?

    Science.gov (United States)

    Vardiman, Phillip; Carrand, David; Gallagher, Philip M.

    2010-01-01

    Stretching prior to activity is universally accepted as an important way to improve performance and help prevent injury. Likewise, limited flexibility has been shown to decrease functional ability and predispose a person to injuries. Although this is commonly accepted, appropriate stretching for children and adolescents involved with sports and…

  1. The Hydrodynamics of DNA Electrophoretic Stretch and Relaxation in a Polymer Solution

    Science.gov (United States)

    Ferree, Sean; Blanch, Harvey W.

    2004-01-01

    Theories of DNA electrophoretic separations generally treat the DNA as a free draining polymer moving in an electric field at a rate that depends on the effective charge density of the molecule. Separations can occur in sieving media ranging from ultradilute polymer solutions to tightly cross-linked gels. It has recently been shown that DNA is not free-draining when both electric and nonelectric forces simultaneously act on the molecule, as occurs when DNA collides with a polymer during electrophoretic separations. Here we show that a semidilute polymer solution screens the hydrodynamic interaction that results from the application of these forces. Fluorescently labeled DNA tethered at one end in a semidilute solution of hydroxyl-ethyl cellulose stretch more in an electric field than they stretch in free solution, and approach free-draining behavior. The steady stretching behavior is predicted without adjustable parameters by a theory developed by Stigter using a hydrodynamic screening length found from effective medium theory. Data on the relaxation of stretched molecules after the electric field is removed agree with the Rouse model prediction, which neglects hydrodynamic interactions. The slowest relaxation time constant, τR, scales with chain length as τR ∼ L1.9±0.17 when analyzed by the data collapse method, and as τR ∼ L2.17±0.17 when analyzed by multiexponential fit. PMID:15240480

  2. Mechanical stretching of proteins-a theoretical survey of the Protein Data Bank

    International Nuclear Information System (INIS)

    Sulkowska, Joanna I; Cieplak, Marek

    2007-01-01

    The mechanical stretching of single proteins has been studied experimentally for about 50 proteins, yielding a variety of force patterns and peak forces. Here we perform a theoretical survey of proteins of known native structure and map out the landscape of possible dynamical behaviours under stretching at constant speed. We consider 7510 proteins comprising not more than 150 amino acids and 239 longer proteins. The model used is constructed based on the native geometry. It is solved by methods of molecular dynamics and validated by comparing the theoretical predictions to experimental results. We characterize the distribution of peak forces and investigate correlations with the system size and with the structure classification as characterized by the CATH scheme. Despite the presence of such correlations, proteins with the same CATH index may belong to different classes of dynamical behaviour. We identify proteins with the biggest forces and show that they belong to few topology classes. We determine which protein segments act as mechanical clamps and show that, in most cases, they correspond to long stretches of parallel β-strands, but other mechanisms are also possible. (topical review)

  3. Dynamic stretching is effective as static stretching at increasing flexibility

    OpenAIRE

    Coons, John M.; Gould, Colleen E.; Kim, Jwa K.; Farley, Richard S.; Caputo, Jennifer L.

    2017-01-01

    This study examined the effect of dynamic and static (standard) stretching on hamstring flexibility. Twenty-five female volleyball players were randomly assigned to dynamic (n = 12) and standard (n = 13) stretching groups. The experimental group trained with repetitive dynamic stretching exercises, while the standard modality group trained with static stretching exercises. The stretching interventions were equivalent in the time at stretch and were performed three days a week for four weeks. ...

  4. Force

    CERN Document Server

    Graybill, George

    2007-01-01

    Forces are at work all around us. Discover what a force is, and different kinds of forces that work on contact and at a distance. We use simple language and vocabulary to make this invisible world easy for students to ""see"" and understand. Examine how forces ""add up"" to create the total force on an object, and reinforce concepts and extend learning with sample problems.

  5. A Combined Experimental and Numerical Modeling Study of the Deformation and Rupture of Axisymmetric Liquid Bridges under Coaxial Stretching.

    Science.gov (United States)

    Zhuang, Jinda; Ju, Y Sungtaek

    2015-09-22

    The deformation and rupture of axisymmetric liquid bridges being stretched between two fully wetted coaxial disks are studied experimentally and theoretically. We numerically solve the time-dependent Navier-Stokes equations while tracking the deformation of the liquid-air interface using the arbitrary Lagrangian-Eulerian (ALE) moving mesh method to fully account for the effects of inertia and viscous forces on bridge dynamics. The effects of the stretching velocity, liquid properties, and liquid volume on the dynamics of liquid bridges are systematically investigated to provide direct experimental validation of our numerical model for stretching velocities as high as 3 m/s. The Ohnesorge number (Oh) of liquid bridges is a primary factor governing the dynamics of liquid bridge rupture, especially the dependence of the rupture distance on the stretching velocity. The rupture distance generally increases with the stretching velocity, far in excess of the static stability limit. For bridges with low Ohnesorge numbers, however, the rupture distance stay nearly constant or decreases with the stretching velocity within certain velocity windows due to the relative rupture position switching and the thread shape change. Our work provides an experimentally validated modeling approach and experimental data to help establish foundation for systematic further studies and applications of liquid bridges.

  6. BSDB: the Biomolecule Stretching Database

    Science.gov (United States)

    Cieplak, Marek; Sikora, Mateusz; Sulkowska, Joanna I.; Witkowski, Bartlomiej

    2011-03-01

    Despite more than a decade of experiments on single biomolecule manipulation, mechanical properties of only several scores of proteins have been measured. A characteristic scale of the force of resistance to stretching, Fmax , has been found to range between ~ 10 and 480 pN. The Biomolecule Stretching Data Base (BSDB) described here provides information about expected values of Fmax for, currently, 17 134 proteins. The values and other characteristics of the unfolding proces, including the nature of identified mechanical clamps, are available at www://info.ifpan.edu.pl/BSDB/. They have been obtained through simulations within a structure-based model which correlates satisfactorily with the available experimental data on stretching. BSDB also lists experimental data and results of the existing all-atom simulations. The database offers a Protein-Data-Bank-wide guide to mechano-stability of proteins. Its description is provided by a forthcoming Nucleic Acids Research paper. Supported by EC FUNMOL project FP7-NMP-2007-SMALL-1, and European Regional Development Fund: Innovative Economy (POIG.01.01.02-00-008/08).

  7. Comparison of one-particle basis set extrapolation to explicitly correlated methods for the calculation of accurate quartic force fields, vibrational frequencies, and spectroscopic constants: application to H2O, N2H+, NO2+, and C2H2.

    Science.gov (United States)

    Huang, Xinchuan; Valeev, Edward F; Lee, Timothy J

    2010-12-28

    One-particle basis set extrapolation is compared with one of the new R12 methods for computing highly accurate quartic force fields (QFFs) and spectroscopic data, including molecular structures, rotational constants, and vibrational frequencies for the H(2)O, N(2)H(+), NO(2)(+), and C(2)H(2) molecules. In general, agreement between the spectroscopic data computed from the best R12 and basis set extrapolation methods is very good with the exception of a few parameters for N(2)H(+) where it is concluded that basis set extrapolation is still preferred. The differences for H(2)O and NO(2)(+) are small and it is concluded that the QFFs from both approaches are more or less equivalent in accuracy. For C(2)H(2), however, a known one-particle basis set deficiency for C-C multiple bonds significantly degrades the quality of results obtained from basis set extrapolation and in this case the R12 approach is clearly preferred over one-particle basis set extrapolation. The R12 approach used in the present study was modified in order to obtain high precision electronic energies, which are needed when computing a QFF. We also investigated including core-correlation explicitly in the R12 calculations, but conclude that current approaches are lacking. Hence core-correlation is computed as a correction using conventional methods. Considering the results for all four molecules, it is concluded that R12 methods will soon replace basis set extrapolation approaches for high accuracy electronic structure applications such as computing QFFs and spectroscopic data for comparison to high-resolution laboratory or astronomical observations, provided one uses a robust R12 method as we have done here. The specific R12 method used in the present study, CCSD(T)(R12), incorporated a reformulation of one intermediate matrix in order to attain machine precision in the electronic energies. Final QFFs for N(2)H(+) and NO(2)(+) were computed, including basis set extrapolation, core-correlation, scalar

  8. Biocatalysis: Unmasked by stretching

    Science.gov (United States)

    Kharlampieva, Eugenia; Tsukruk, Vladimir V.

    2009-09-01

    The biocatalytic activity of enzyme-loaded responsive layer-by-layer films can be switched on and off by simple mechanical stretching. Soft materials could thus be used to trigger biochemical reactions under mechanical action, with potential therapeutic applications.

  9. Numerical Study of Laminar Forced Convection of Water/Al2o3 Nanofluid in an Annulus with Constant Wall Temperature

    Directory of Open Access Journals (Sweden)

    Amin Kashani

    2013-04-01

    Full Text Available Laminar forced convection of a nanofluid consisting of water and Al2O3 in a horizontal annulus has been studied numerically. Two-phase mixture model has been used to investigate thermal behaviors of the nanofluid over constant temperature thermal boundary condition and with different volume concentration of nanoparticles. Comparisons with previously published experimental and analytical works on flow behavior in horizontal annulus show good agreements between the results as volume fraction is zero. In general convective heat transfer coefficient increases with nanoparticle concentration. ABSTRAK: Kertaskerja ini mengkaji secara numerik olakan paksa bendalir lamina yang menganduangi air dan Al2O3 didalam anulus mendatar. Model campuran dua fasa digunakan bagi mengkaji tingkah laku haba bendalir nano pada keadaan suhu malar dengan kepekatan nanopartikel berbeza. Perbandingan dengan karya eksperimen dan analitikal yang telah diterbitkan menunjukkan bahawa kelakuan aliran didalm anulus mendatar adalah baik apabila pecahan isipadu adalah sifar. Pada amnya, pekali pemindahan haba olakan meningkat dengan kepekatan nanopartikel. KEYWORDS: nanofluid; volume concentration; heat transfer enhancement; laminar flow convection; annulus

  10. Universal linear motor driven Leg Press Dynamometer and concept of Serial Stretch Loading

    Directory of Open Access Journals (Sweden)

    Dušan Hamar

    2015-08-01

    Full Text Available Paper deals with backgrounds and principles of universal linear motor driven leg press dynamometer and concept of serial stretch loading. The device is based on two computer controlled linear motors mounted to the horizontal rails. As the motors can keep either constant resistance force in selected position or velocity in both directions, the system allows simulation of any mode of muscle contraction. In addition, it also can generate defined serial stretch stimuli in a form of repeated force peaks. This is achieved by short segments of reversed velocity (in concentric phase or acceleration (in eccentric phase. Such stimuli, generated at the rate of 10 Hz, have proven to be a more efficient means for the improvement of rate of the force development. This capability not only affects performance in many sports, but also plays a substantial role in prevention of falls and their consequences. Universal linear motor driven and computer controlled dynamometer with its unique feature to generate serial stretch stimuli seems to be an efficient and useful tool for enhancing strength training effects on neuromuscular function not only in athletes, but as well as in senior population and rehabilitation patients.

  11. Summary of the stretching tectonics research

    International Nuclear Information System (INIS)

    Yu Dagan

    1994-01-01

    The rise of stretching tectonics is established on the basis of recent structural geology theory, the establishment of metamorphic nucleus complex structural model on one hand plays an important promoting art to the development of stretching structure, on the other hand, it needs constant supplement and perfection in practice. Metamorphic nucleus complex is the carrier of comparatively deep geological information in vertical section of the crust and has wide distribution in the era of south China. Evidently, it can be taken as the 'key' to understanding the deep and studying the basement, Strengthening the study will play the important promoting role to the deep prospecting. The study of stretching tectonics is not only limited within the range of structure and metamorphism, but combine with the studies of sedimentation, magmatism, metamorphism and mineralization, thus form a new field of tectonic geology of self-developing system

  12. Lattice stretching bistability and dynamic heterogeneity

    DEFF Research Database (Denmark)

    Christiansen, Peter Leth; Savin, A. V.; Zolotaryuk, A. V.

    2012-01-01

    A simple one-dimensional lattice model is suggested to describe the experimentally observed plateau in force-stretching diagrams for some macromolecules. This chain model involves the nearest-neighbor interaction of a Morse-like potential (required to have a saturation branch) and a harmonic second......-neighbor coupling. Under an external stretching applied to the chain ends, the intersite Morse-like potential results in the appearance of a double-well potential within each chain monomer, whereas the interaction between the second neighbors provides a homogeneous bistable (degenerate) ground state, at least...

  13. AN EXPERIMENTAL STUDY FOR HEAT TRANSFER ENHANCEMENT BY LAMINAR FORCED CONVECTION FROM HORIZONTAL AND INCLINED TUBE HEATED WITH CONSTANT HEAT FLUX, USING TWO TYPES OF POROUS MEDIA

    Directory of Open Access Journals (Sweden)

    Thamir K. Jassem

    2015-02-01

    Full Text Available An experimental forced laminar study was presented in this research for an air flowing through a circular channel for different angles ( ,30o,45o,60o, the channel was heated at constant heat flux , the channel also was packed with steel and glass spheres respectively . The tests were done for three values of Peclets number (2111.71,3945.42,4575.47 with changing the heat flux for each case and five times for each number.The results showed that the dimensionless temperature distribution  will decrease with increasing the dimensionless channel length for all cases with changing Peclet number, heat flux and inclination angles, and its lowest value will be for glass spheres at highest flux, while at lower flux for , and the decreasing in dimensionless temperature was closed for both types of packed at other inclination angles.The study declared that the local Nusselt number decreases with increasing the dimensionless length of the channel for both packeds and for different applied heat flux, also through this study it was declared that the average Nusselt increases as Peclet number increases for both packed. Its value for the glass spheres is greater than the steel spheres with percentage (98.3% at small Peclet, and percentage (97.2% at large Peclet number for the horizontal tube, and (98.3% at small Peclet number and (97.8% at large Peclet number at  .Through this study its was found that average Nusselt number increases along the channel as the heat flux increases, because the bulk temperature will increase as the flow proceeds toward the end of the channel , so the heat transfer coefficient will increase.  It was declared from this study that in the case of the steel packed the heat transfer will occur mainly by conduction, while in the case of glass packed the heat transfer will occur mainly by laminar forced convection, where the lowest Nusselt number (Nu=3.8 was found when the pipe is horizontal and lowest heat flux and lowest Peclet number.  

  14. Anisotropic dewetting on stretched elastomeric substrates.

    Science.gov (United States)

    Qiao, L; He, L H

    2008-08-01

    We study the instability of a very thin liquid film resting on a uniformly stretched soft elastomeric substrate driven by van der Waals forces. A linear stability analysis shows that the critical fluctuation wavelength in the tensile direction is larger than those in the other directions. The magnitudes of the critical wavelengths are adjustable in the sense that they depend on the principal stretch of the substrate. For example, when the principal stretch of the substrate varies from 1.0 (unstretched) to 3.0, the range of the critical wavelength in the tensile direction increases by 7.0% while that normal to the tensile direction decreases by 8.7%. Therefore, the phenomenon may find potential applications in creating tunable topographically patterned surfaces with nano- to microscale features.

  15. Experimental force modeling for deformation machining stretching ...

    Indian Academy of Sciences (India)

    Deformation machining is a hybrid process that combines two manufacturing processes—thin structure machining and single-point incremental forming. This process enables the creation of complex structures and geometries, which would be rather difficult or sometimes impossible to manufacture. A comprehensive ...

  16. Experimental force modeling for deformation machining stretching ...

    Indian Academy of Sciences (India)

    ARSHPREET SINGH

    Deformation machining is a hybrid process that combines two manufacturing processes—thin structure machining and ... structures and geometries, which would be rather difficult or sometimes impossible to manufacture. A com- prehensive ... sheet metal is deformed locally into plastic stage, enabling creation of complex ...

  17. Nuclear constants

    International Nuclear Information System (INIS)

    Foos, J.

    1999-01-01

    This paper is written in two tables. The first one describes the different particles (bosons and fermions). The second one gives the isotopes nuclear constants of the different elements, for Z = 1 to 56. (A.L.B.)

  18. Nuclear constants

    International Nuclear Information System (INIS)

    Foos, J.

    2000-01-01

    This paper is written in two tables. The first one describes the different particles (bosons and fermions). The second one gives the isotopes nuclear constants of the different elements, for Z = 56 to 68. (A.L.B.)

  19. Nuclear constants

    International Nuclear Information System (INIS)

    Foos, J.

    1998-01-01

    This paper is made of two tables. The first table describes the different particles (bosons and fermions) while the second one gives the nuclear constants of isotopes from the different elements with Z = 1 to 25. (J.S.)

  20. Nuclear constants

    International Nuclear Information System (INIS)

    Foos, J.

    1999-01-01

    This paper is written in two tables. The first one describes the different particles (bosons and fermions). The second one gives the isotopes nuclear constants of the different elements, for Z = 56 to 68. (A.L.B.)

  1. Stretching & Flexibility: An Interactive Encyclopedia of Stretching. [CD-ROM].

    Science.gov (United States)

    2002

    This CD-ROM offers 140 different stretches in full-motion video sequences. It focuses on the proper techniques for overall physical fitness, injury prevention and rehabilitation, and 23 different sports (e.g., golf, running, soccer, skiing, climbing, football, and baseball). Topics include stretching for sports; stretching awareness and education…

  2. Stretching the Border

    DEFF Research Database (Denmark)

    Horstmann, Alexander

    2014-01-01

    In this paper, I hope to add a complementary perspective to James Scott’s recent work on avoidance strategies of subaltern mountain people by focusing on what I call the refugee public. The educated Karen elite uses the space of exile in the Thai borderland to reconstitute resources and to re-ent......-based organizations succeed to stretch the border by establishing a firm presence that is supported by the international humanitarian economy in the refugee camps in Northwestern Thailand....

  3. Effect of the ion force on the stability constants of the complexes LnCl{sup 2+} and LnCl{sub 2}{sup +} of Europium and Lutetium; Efecto de la fuerza ionica sobre las constantes de estabilidad de los complejos LnCl{sup 2+} y LnCl{sub 2}{sup +} de Europium y Lutetium

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez R, E.; Jimenez R, M.; Solache R, M. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2004-07-01

    A study is presented on the determination of the constants of stability of those complex LnCI{sup 3-n}{sub n} (where Ln = Eu{sup 3+} and Lu{sup 3+} and n = 1 and 2), by means of a method of extraction with solvent, to constant temperature (303 K) and in means of high ionic force (1- 3M H CI/HCIO{sub 4}). It is also presented the application of the theory of the specific interaction of ions (SIT) of Bronsted-Guggenheim-Scatchard for the extrapolation of the values to infinite dilution. (Author)

  4. Kontrola kvalitete stretch folije

    OpenAIRE

    Gržanić, Nino

    2016-01-01

    U završnom radu opisan je postupak ekstrudiranja i kontrole kvalitete stretch folije koji se koristi u firmi Bomark-Pak radi osiguravanja najbolje kvalitete. Kontrola kreče kod uvoza repromaterijala, nastavlja se kod izrade folije na stroju, te se glavni dio odvija nakon izrade gotovg proizvoda. U radu ćemo detaljno objasniti svaki pojedini korak, zašto se on vrši, te uz pomoć kojih mjernih instrumenata se izvršava.

  5. Stretched cell cycle model for proliferating lymphocytes

    Science.gov (United States)

    Dowling, Mark R.; Kan, Andrey; Heinzel, Susanne; Zhou, Jie H. S.; Marchingo, Julia M.; Wellard, Cameron J.; Markham, John F.; Hodgkin, Philip D.

    2014-01-01

    Stochastic variation in cell cycle time is a consistent feature of otherwise similar cells within a growing population. Classic studies concluded that the bulk of the variation occurs in the G1 phase, and many mathematical models assume a constant time for traversing the S/G2/M phases. By direct observation of transgenic fluorescent fusion proteins that report the onset of S phase, we establish that dividing B and T lymphocytes spend a near-fixed proportion of total division time in S/G2/M phases, and this proportion is correlated between sibling cells. This result is inconsistent with models that assume independent times for consecutive phases. Instead, we propose a stretching model for dividing lymphocytes where all parts of the cell cycle are proportional to total division time. Data fitting based on a stretched cell cycle model can significantly improve estimates of cell cycle parameters drawn from DNA labeling data used to monitor immune cell dynamics. PMID:24733943

  6. Cosmological constant as integration constant

    Science.gov (United States)

    Treder, H.-J.

    1994-08-01

    Einstein's field theory of elementary particles (Einstein 1919) yields black holes with a mass M approximately G-1 Lambda-1/2 c2 and a charge Q approximately G-1/2 Lambda-1/2 c2, their curvature radius is Lambda-1/2. Here Lambda is an integration constant of Einstein's 'trace-less' gravitation equations. The choice Lambda = G-1 h-1 c3 for this constant defines Planck ions and implies 'strong-gravity'. The choice Lambda = lambda = 3Hinf exp 2 c-2 (where Hinf means the Hubble parameter of a final de Sitter cosmos) involves 'weak-gravity' and describes an electro-vac spherical universe.

  7. Immediate effects of different types of stretching exercises on badminton jump smash.

    Science.gov (United States)

    Jang, Hwi S; Kim, Daeho; Park, Jihong

    2017-04-13

    Since different types of stretching exercises may alter athletic performance, we compared the effects of three types of stretching exercises on badminton jump smash. Sixteen male collegiate badminton players performed one of three different stretching exercises in a counterbalanced order on different days. Static stretching had seven typical stretches, while dynamic stretching involved nine dynamic movements, and resistance dynamic stretching was performed with weighted vests and dumbbells. Before and after each stretching exercise, subjects performed 20 trials of jump smashes. Dependent measurements were the jump heights during jump smashes, velocities of jump-smashed shuttlecocks, and drop points of jump-smashed shuttlecocks. To test the effects of each stretching exercise, we performed mixed model ANOVAs and calculated between-time effect sizes (ES). Each stretching exercise improved the jump heights during jump smashes (type main effect: F2,75= 1.19, p=0.31; static stretching: 22.1%, pstretching: 30.1%, pstretching: 17.7%, p=0.03, ES: 0.98) and velocities of jump-smashed shuttlecocks (type main effect: F2,75= 2.18, p=0.12; static stretching: 5.7%, p=0.61, ES: 0.39; dynamic stretching: 3.4%, p=0.94, ES: 0.28; resistance dynamic stretching: 6%, p=0.50, ES: 0.66). However, there were no differences among the stretching exercises for any measurement. The drop point of jump-smashed shuttlecocks did not change (interaction: F2,75= 0.88, p=0.42). All stretching exercises improved badminton jump smash performance, but we could not determine the best protocol. Since badminton requires high-speed movement and explosive force, we suggest performing dynamic stretching or resistance dynamic stretching.

  8. Possible Cause of Nonlinear Tension Rise in Activated Muscle Fiber during Stretching.

    Science.gov (United States)

    Kochubei, P V; Bershitsky, S Yu

    2016-11-01

    Tension in contracting muscle fiber under conditions of ramp stretching rapidly increases, but after reaching a critical stretch P c sharply decreases. To find out the cause of these changes in muscle fiber tension, we stopped stretching before and after reaching P c and left the fiber stretched for 50 msec. After rapid tension drop, the transient tension rise not accompanied by fiber stiffness increase was observed only in fibers heated to 25°C and stretched to P c . Under other experimental conditions, this growth was absent. We suppose that stretch of the fiber to P c induces transition of stereo-specifically attached myosin heads to pre-power stroke state and when the stretching is stopped, they make their step on actin and generate force. When the tension reaches P c , all stereospecifically attached myosin heads turn out to be non-stereospecifically, or weakly attached to actin, and are unable to make the force-generating step.

  9. Acute Effects of Dynamic Stretching on Muscle Flexibility and Performance: An Analysis of the Current Literature.

    Science.gov (United States)

    Opplert, Jules; Babault, Nicolas

    2018-02-01

    Stretching has long been used in many physical activities to increase range of motion (ROM) around a joint. Stretching also has other acute effects on the neuromuscular system. For instance, significant reductions in maximal voluntary strength, muscle power or evoked contractile properties have been recorded immediately after a single bout of static stretching, raising interest in other stretching modalities. Thus, the effects of dynamic stretching on subsequent muscular performance have been questioned. This review aimed to investigate performance and physiological alterations following dynamic stretching. There is a substantial amount of evidence pointing out the positive effects on ROM and subsequent performance (force, power, sprint and jump). The larger ROM would be mainly attributable to reduced stiffness of the muscle-tendon unit, while the improved muscular performance to temperature and potentiation-related mechanisms caused by the voluntary contraction associated with dynamic stretching. Therefore, if the goal of a warm-up is to increase joint ROM and to enhance muscle force and/or power, dynamic stretching seems to be a suitable alternative to static stretching. Nevertheless, numerous studies reporting no alteration or even performance impairment have highlighted possible mitigating factors (such as stretch duration, amplitude or velocity). Accordingly, ballistic stretching, a form of dynamic stretching with greater velocities, would be less beneficial than controlled dynamic stretching. Notwithstanding, the literature shows that inconsistent description of stretch procedures has been an important deterrent to reaching a clear consensus. In this review, we highlight the need for future studies reporting homogeneous, clearly described stretching protocols, and propose a clarified stretching terminology and methodology.

  10. A discrete electromechanical model for human cardiac tissue: effects of stretch-activated currents and stretch conditions on restitution properties and spiral wave dynamics.

    Directory of Open Access Journals (Sweden)

    Louis D Weise

    Full Text Available We introduce an electromechanical model for human cardiac tissue which couples a biophysical model of cardiac excitation (Tusscher, Noble, Noble, Panfilov, 2006 and tension development (adjusted Niederer, Hunter, Smith, 2006 model with a discrete elastic mass-lattice model. The equations for the excitation processes are solved with a finite difference approach, and the equations of the mass-lattice model are solved using Verlet integration. This allows the coupled problem to be solved with high numerical resolution. Passive mechanical properties of the mass-lattice model are described by a generalized Hooke's law for finite deformations (Seth material. Active mechanical contraction is initiated by changes of the intracellular calcium concentration, which is a variable of the electrical model. Mechanical deformation feeds back on the electrophysiology via stretch-activated ion channels whose conductivity is controlled by the local stretch of the medium. We apply the model to study how stretch-activated currents affect the action potential shape, restitution properties, and dynamics of spiral waves, under constant stretch, and dynamic stretch caused by active mechanical contraction. We find that stretch conditions substantially affect these properties via stretch-activated currents. In constantly stretched medium, we observe a substantial decrease in conduction velocity, and an increase of action potential duration; whereas, with dynamic stretch, action potential duration is increased only slightly, and the conduction velocity restitution curve becomes biphasic. Moreover, in constantly stretched medium, we find an increase of the core size and period of a spiral wave, but no change in rotation dynamics; in contrast, in the dynamically stretching medium, we observe spiral drift. Our results may be important to understand how altered stretch conditions affect the heart's functioning.

  11. Pre-exercise stretching does not impact upon running economy.

    Science.gov (United States)

    Hayes, Philip R; Walker, Adrian

    2007-11-01

    Pre-exercise stretching has been widely reported to reduce performance in tasks requiring maximal or near-maximal force or torque. The purpose of this study was to compare the effects of 3 different pre-exercise stretching routines on running economy. Seven competitive male middle and long-distance runners (mean +/- SD) age: 32.5 +/- 7.7 years; height: 175.0 +/- 8.8 cm; mass: 67.8 +/- 8.6 kg; V(.-)O2max: 66.8 +/- 7.0 ml x kg(-1) x min(-1)) volunteered to participate in this study. Each participant completed 4 different pre-exercise conditions: (a) a control condition, (b) static stretching, (c) progressive static stretching, and (d) dynamic stretching. Each stretching routine consisted of 2 x 30-second stretches for each of 5 exercises. Dependent variables measured were sit and reach test before and after each pre-exercise routine, running economy (ml x kg(-1) x km(-1)), and steady-state oxygen uptake (ml x kg(-1) x min(-1)), which were measured during the final 3 minutes of a 10-minute run below lactate threshold. All 3 stretching routines resulted in an increase in the range of movement (p = 0.008). There was no change in either running economy (p = 0.915) or steady-state V(.-)O2 (p = 0.943). The lack of change in running economy was most likely because it was assessed after a period of submaximal running, which may have masked any effects from the stretching protocols. Previously reported reductions in performance have been attributed to reduced motor unit activation, presumably IIX. In this study, these motor units were likely not to have been recruited; this may explain the unimpaired performance. This study suggests that pre-exercise stretching has no impact upon running economy or submaximal exercise oxygen cost.

  12. Equibiaxial cyclic stretch stimulates fibroblasts to rapidly remodel fibrin.

    Science.gov (United States)

    Balestrini, Jenna Leigh; Billiar, Kristen Lawrence

    2006-01-01

    Understanding the effects of the mechanical environment on wound healing is critical for developing more effective treatments to reduce scar formation and contracture. The aim of this study was to investigate the effects of dynamic mechanical stretch on cell-mediated early wound remodeling independent of matrix alignment which obscures more subtle remodeling mechanisms. Cyclic equibiaxial stretch (16% stretch at 0.2 Hz) was applied to fibroblast-populated fibrin gel in vitro wound models for eight days. Compaction, density, tensile strength, and collagen content were quantified as functional measures of remodeling. Stretched samples were approximately ten times stronger, eight-fold more dense, and eight times thinner than statically cultured samples. These changes were accompanied by a 15% increase in net collagen but no significant differences in cell number or viability. When collagen crosslinking was inhibited in stretched samples, the extensibility increased and the strength decreased. The apparent weakening was due to a reduction in compaction rather than a decrease in ability of the tissue to withstand tensile forces. Interestingly, inhibiting collagen crosslinking had no measurable effects on the statically cultured samples. These results indicate that amplified cell-mediated compaction and even a slight addition in collagen content play substantial roles in mechanically induced wound strengthening. These findings increase our understanding of how mechanical forces guide the healing response in skin, and the methods employed in this study may also prove valuable tools for investigating stretch-induced remodeling of other planar connective tissues and for creating mechanically robust engineered tissues.

  13. Efeitos agudos do alongamento estático no desempenho da força dinâmica em homens jovens Acute effects of static stretching in dynamic force performance in young men

    Directory of Open Access Journals (Sweden)

    Patrick Wander Endlich

    2009-06-01

    Full Text Available INTRODUÇÃO: O alongamento muscular é frequentemente utilizado nas práticas desportivas, com o objetivo de aumentar a flexibilidade muscular e amplitude articular, assim como diminuir o risco de lesões e melhorar o desempenho atlético. OBJETIVO: Analisar o efeito agudo do alongamento com diferentes tempos no desempenho da força dinâmica de membros superiores e inferiores em homens jovens. MÉTODOS: Participaram da amostra 14 voluntários do sexo masculino com idade de 23 ± 2 anos, peso corporal de 84 ± 10kg, estatura de178 ± 7cm, IMC de 26 ± 2kg/m² e percentual de gordura de 11 ± 3%. Eles foram avaliados com o teste de 10RM em três situações distintas: condição sem alongamento (SA, aquecimento especifico seguido do teste de 10-RM; condição com oito minutos de alongamento (AL-8, uma sessão de alongamento estático com oito minutos de duração, seguido do aquecimento e teste de 10RM; e a condição alongamento 16 minutos (AL-16, 16 minutos de alongamento seguidos dos procedimentos descritos anteriormente. Os testes foram feitos no supino reto e leg-press 45º; os alongamentos foram selecionados de forma a atingir as musculaturas solicitadas nos respectivos exercícios. RESULTADOS: Houve redução de 9,2% da força muscular dinâmica de membros superiores em comparação dos grupos SA e AL16, e entre os grupos AL8 e AL16 (p BACKGROUND: Muscular stretching is frequently used in sports practice with the aim to increase muscular flexibility and joint range of motion as well as to reduce injury risks and to improve athletic performance. AIM: To analyze the acute effect of stretching with different times in the dynamic strength performance of lower and upper extremities in young men. METHODS: The sample was composed by 14 healthy male volunteers aged 23 ± 2 years, weight of 84 ± 10 Kg , height of 178 ± 7 cm, BMI of 26 ± 2 Kg/m2 and body fat of 11 ± 3 %. They were evaluated in a 10-maximum repetition test (10-RM in three

  14. Measurement of Reversed Extension Flow using the Filament Stretch Rheometer

    DEFF Research Database (Denmark)

    Rasmussen, Henrik K.; Skov, Anne Ladegaard; Nielsen, Jens Kromann

    2008-01-01

    ). The latter is applicable on highly extensible elastomers, whereas in LAOE measurements on liquids (including polymer melts) the LAOE flow needs to be imposed upon a constant strain rate uniaxial elongation. The used Filament Stretching Rheometer allows measurements on polymeric fluids (including polymeric...... melts) from room temperature until 200 degrees C....

  15. Twist-stretch profiles of DNA chains

    Science.gov (United States)

    Zoli, Marco

    2017-06-01

    Helical molecules change their twist number under the effect of a mechanical load. We study the twist-stretch relation for a set of short DNA molecules modeled by a mesoscopic Hamiltonian. Finite temperature path integral techniques are applied to generate a large ensemble of possible configurations for the base pairs of the sequence. The model also accounts for the bending and twisting fluctuations between adjacent base pairs along the molecules stack. Simulating a broad range of twisting conformation, we compute the helix structural parameters by averaging over the ensemble of base pairs configurations. The method selects, for any applied force, the average twist angle which minimizes the molecule’s free energy. It is found that the chains generally over-twist under an applied stretching and the over-twisting is physically associated to the contraction of the average helix diameter, i.e. to the damping of the base pair fluctuations. Instead, assuming that the maximum amplitude of the bending fluctuations may decrease against the external load, the DNA molecule first over-twists for weak applied forces and then untwists above a characteristic force value. Our results are discussed in relation to available experimental information albeit for kilo-base long molecules.

  16. Stretch Moduli of Ribonucleotide Embedded Short DNAs

    Science.gov (United States)

    Chiu, Hsiang-Chih; Koh, Kyung Duk; Riedo, Elisa; Storici, Francesca

    2013-03-01

    Understanding the mechanical properties of DNA is essential to comprehending the dynamics of many cellular functions. DNA deformations are involved in many mechanisms when genetic information needs to be stored and used. In addition, recent studies have found that Ribonucleotides (rNMPs) are among the most common non-standard nucleotides present in DNA. The presences of rNMPs in DNA might cause mutation, fragility or genotoxicity of chromosome but how they influence the structure and mechanical properties of DNA remains unclear. By means of Atomic Force Microscopy (AFM) based single molecule spectroscopy, we measure the stretch moduli of double stranded DNAs (dsDNA) with 30 base pairs and 5 equally embedded rNMPs. The dsDNAs are anchored on gold substrate via thiol chemistry, while the AFM tip is used to pick up and stretch the dsDNA from its free end through biotin-streptavidin bonding. Our preliminary results indicate that the inclusion of rNMPs in dsDNA might significantly change its stretch modulus, which might be important in some biological processes.

  17. Cheap but accurate calculation of chemical reaction rate constants from ab initio data, via system-specific, black-box force fields.

    Science.gov (United States)

    Steffen, Julien; Hartke, Bernd

    2017-10-28

    Building on the recently published quantum-mechanically derived force field (QMDFF) and its empirical valence bond extension, EVB-QMDFF, it is now possible to generate a reliable potential energy surface for any given elementary reaction step in an essentially black box manner. This requires a limited and pre-defined set of reference data near the reaction path and generates an accurate approximation of the reference potential energy surface, on and off the reaction path. This intermediate representation can be used to generate reaction rate data, with far better accuracy and reliability than with traditional approaches based on transition state theory (TST) or variational extensions thereof (VTST), even if those include sophisticated tunneling corrections. However, the additional expense at the reference level remains very modest. We demonstrate all this for three arbitrarily chosen example reactions.

  18. Numerical study for forced MHD convection heat transfer of a nanofluid in a square cavity with a cylinder of constant heat flux

    Science.gov (United States)

    Hassanpour, Amin; Ranjbar, A. A.; Sheikholeslami, M.

    2018-02-01

    In this research, flow and forced convection heat transfer of a water-copper nanofluid in the presence of magnetic field is studied. The walls of the square ventilation cavity are insulated. The dominating equations are solved by implementing the finite-volume method (FVM) using the Semi-Implicit Method for Pressure-Linked Equations (SIMPLE) algorithm. The effects of Hartmann number, nanoparticles volume fraction and Reynolds number on the flow and heat transfer characteristics were examined. The results demonstrate that increasing Reynolds and Hartmann numbers lead to increase the average Nusselt number. By evaluating the geometrical parameters, it was found that the size and number of vortices in the flow field decrease by increasing the inlet width. Besides, the increase of the average Nusselt number occurs with the increase of the inlet width. Moreover, it has been observed that the effect of the Hartmann number is more pronounced for higher Reynolds numbers.

  19. Magnitude and duration of stretch modulate fibroblast remodeling.

    Science.gov (United States)

    Balestrini, Jenna L; Billiar, Kristen L

    2009-05-01

    Mechanical cues modulate fibroblast tractional forces and remodeling of extracellular matrix in healthy tissue, healing wounds, and engineered matrices. The goal of the present study is to establish dose-response relationships between stretch parameters (magnitude and duration per day) and matrix remodeling metrics (compaction, strength, extensibility, collagen content, contraction, and cellularity). Cyclic equibiaxial stretch of 2-16% was applied to fibroblast-populated fibrin gels for either 6 h or 24 h/day for 8 days. Trends in matrix remodeling metrics as a function of stretch magnitude and duration were analyzed using regression analysis. The compaction and ultimate tensile strength of the tissues increased in a dose-dependent manner with increasing stretch magnitude, yet remained unaffected by the duration in which they were cycled (6 h/day versus 24 h/day). Collagen density increased exponentially as a function of both the magnitude and duration of stretch, with samples stretched for the reduced duration per day having the highest levels of collagen accumulation. Cell number and failure tension were also dependent on both the magnitude and duration of stretch, although stretch-induced increases in these metrics were only present in the samples loaded for 6 h/day. Our results indicate that both the magnitude and the duration per day of stretch are critical parameters in modulating fibroblast remodeling of the extracellular matrix, and that these two factors regulate different aspects of this remodeling. These findings move us one step closer to fully characterizing culture conditions for tissue equivalents, developing improved wound healing treatments and understanding tissue responses to changes in mechanical environments during growth, repair, and disease states.

  20. Stretch-minimising stream surfaces

    KAUST Repository

    Barton, Michael

    2015-05-01

    We study the problem of finding stretch-minimising stream surfaces in a divergence-free vector field. These surfaces are generated by motions of seed curves that propagate through the field in a stretch minimising manner, i.e., they move without stretching or shrinking, preserving the length of their arbitrary arc. In general fields, such curves may not exist. How-ever, the divergence-free constraint gives rise to these \\'stretch-free\\' curves that are locally arc-length preserving when infinitesimally propagated. Several families of stretch-free curves are identified and used as initial guesses for stream surface generation. These surfaces are subsequently globally optimised to obtain the best stretch-minimising stream surfaces in a given divergence-free vector field. Our algorithm was tested on benchmark datasets, proving its applicability to incompressible fluid flow simulations, where our stretch-minimising stream surfaces realistically reflect the flow of a flexible univariate object. © 2015 Elsevier Inc. All rights reserved.

  1. Acute Muscle Stretching and Shoulder Position Sense

    OpenAIRE

    Björklund, Martin; Djupsjöbacka, Mats; Crenshaw, Albert G

    2006-01-01

    Context: Stretching is common among athletes as a potential method for injury prevention. Stretching-induced changes in the muscle spindle properties are a suggested mechanism, which may imply reduced proprioception after stretching; however, little is known of this association.

  2. Stretch-induced intussuceptive and sprouting angiogenesis in the chick chorioallantoic membrane

    OpenAIRE

    Belle, Janeil; Ysasi, Alexandra; Bennett, Robert D.; Filipovic, Nenad; Imani Nejad, Mohammad; Trumper, David L.; Ackermann, Maximilian; Wagner, Willi; Tsuda, Akira; Konerding, Moritz A.; Mentzer, Steven J.

    2014-01-01

    Vascular systems grow and remodel in response to not only metabolic needs, but also mechanical influences as well. Here, we investigated the influence of tissue-level mechanical forces on the patterning and structure of the chick chorioallantoic membrane (CAM) microcirculation. A dipole stretch field was applied to the CAM using custom computer-controlled servomotors. The topography of the stretch field was mapped using finite element models. After 3 days of stretch, Sholl analysis of the CAM...

  3. Effects of Static Stretching and Playing Soccer on Knee Laxity.

    Science.gov (United States)

    Baumgart, Christian; Gokeler, Alli; Donath, Lars; Hoppe, Matthias W; Freiwald, Jürgen

    2015-11-01

    This study investigated exercise-induced effects of static stretching and playing soccer on anterior tibial translation (ATT) of the knee joint. Randomized controlled trial. University biomechanics laboratory. Thirty-one athletes were randomly assigned into a stretching (26.9 ± 6.2 years, 1.77 ± 0.09 m, 67.9 ± 10.7 kg) and a control group (27.9 ± 7.4 years, 1.75 ± 0.08 m, 72.0 ± 14.9 kg). Thirty-one amateur soccer players in an additional soccer group (25.1 ± 5.6 years, 1.74 ± 0.10 m, 71.8 ± 14.8 kg). All participants had no history of knee injury requiring surgery and any previous knee ligament or cartilage injury. The stretching group performed 4 different static stretching exercises with a duration of 2 × 20 seconds interspersed with breaks of 10 seconds. The soccer group completed a 90-minute soccer-specific training program. The control group did not perform any physical activity for approximately 30 minutes. Anterior tibial translation was measured with the KT-1000 knee arthrometer at forces of 67 N, 89 N, and maximal manual force (Max) before and after the intervention. There was a significant increase in ATT after static stretching and playing soccer at all applied forces. Maximal manual testing revealed a mean increase of ATT after static stretching of 2.1 ± 1.6 mm (P static stretching at 67 and 89 N is significantly higher than in controls. At maximum manual testing, significant differences were evident between all groups. Static stretching and playing soccer increase ATT and may consequently influence mechanical factors of the anterior cruciate ligament. The ATT increase after static stretching was greater than after playing soccer. The observed increase in ATT after static stretching and playing soccer may be associated with changes in kinesthetic perception and sensorimotor control, activation of muscles, joint stability, overall performance, and higher injury risk.

  4. High-Accuracy Quartic Force Field Calculations for the Spectroscopic Constants and Vibrational Frequencies of 1(exp 1)A' l-C3H(-): A Possible Link to Lines Observed in the Horsehead Nebula PDR

    Science.gov (United States)

    Fortenberry, Ryan C.; Huang, Xinchuan; Crawford, T. Daniel; Lee, Timothy J.

    2013-01-01

    It has been shown that rotational lines observed in the Horsehead nebula photon-dominated-region (PDR) are probably not caused by l-C3H+, as was originally suggested. In the search for viable alternative candidate carriers, quartic force fields are employed here to provide highly accurate rotational constants, as well as fundamental vibrational frequencies, for another candidate carrier: 1 (sup 1)A' C3H(-). The ab initio computed spectroscopic constants provided in this work are, compared to those necessary to define the observed lines, as accurate as the computed spectroscopic constants for many of the known interstellar anions. Additionally, the computed D-eff for C3H(-) is three times closer to the D deduced from the observed Horsehead nebula lines relative to l-C3H(+). As a result, 1 (sup 1)A' C3H(-). is a more viable candidate for these observed rotational transitions and would be the seventh confirmed interstellar anion detected within the past decade and the first C(sub n)H(-) molecular anion with an odd n.

  5. Acute effect of a ballistic and a static stretching exercise bout on flexibility and maximal strength.

    Science.gov (United States)

    Bacurau, Reury Frank Pereira; Monteiro, Gizele Assis; Ugrinowitsch, Carlos; Tricoli, Valmor; Cabral, Leonardo Ferreira; Aoki, Marcelo Saldanha

    2009-01-01

    Different stretching techniques have been used during warm-up routines. However, these routines may decrease force production. The purpose of this study was to compare the acute effect of a ballistic and a static stretching protocol on lower-limb maximal strength. Fourteen physically active women (169.3 +/- 8.2 cm; 64.9 +/- 5.9 kg; 23.1 +/- 3.6 years) performed three experimental sessions: a control session (estimation of 45 degrees leg press one-repetition maximum [1RM]), a ballistic session (20 minutes of ballistic stretch and 45 degrees leg press 1RM), and a static session (20 minutes of static stretch and 45 degrees leg press 1RM). Maximal strength decreased after static stretching (213.2 +/- 36.1 to 184.6 +/- 28.9 kg), but it was unaffected by ballistic stretching (208.4 +/- 34.8 kg). In addition, static stretching exercises produce a greater acute improvement in flexibility compared with ballistic stretching exercises. Consequently, static stretching may not be recommended before athletic events or physical activities that require high levels of force. On the other hand, ballistic stretching could be more appropriate because it seems less likely to decrease maximal strength.

  6. Hydraulic fracture during epithelial stretching.

    Science.gov (United States)

    Casares, Laura; Vincent, Romaric; Zalvidea, Dobryna; Campillo, Noelia; Navajas, Daniel; Arroyo, Marino; Trepat, Xavier

    2015-03-01

    The origin of fracture in epithelial cell sheets subject to stretch is commonly attributed to excess tension in the cells' cytoskeleton, in the plasma membrane, or in cell-cell contacts. Here, we demonstrate that for a variety of synthetic and physiological hydrogel substrates the formation of epithelial cracks is caused by tissue stretching independently of epithelial tension. We show that the origin of the cracks is hydraulic; they result from a transient pressure build-up in the substrate during stretch and compression manoeuvres. After pressure equilibration, cracks heal readily through actomyosin-dependent mechanisms. The observed phenomenology is captured by the theory of poroelasticity, which predicts the size and healing dynamics of epithelial cracks as a function of the stiffness, geometry and composition of the hydrogel substrate. Our findings demonstrate that epithelial integrity is determined in a tension-independent manner by the coupling between tissue stretching and matrix hydraulics.

  7. Ca{sup 2+} influx and ATP release mediated by mechanical stretch in human lung fibroblasts

    Energy Technology Data Exchange (ETDEWEB)

    Murata, Naohiko [Department of Respiratory Medicine, Nagoya University Graduate School of Medicine, Nagoya 466-8550 (Japan); Ito, Satoru, E-mail: itori@med.nagoya-u.ac.jp [Department of Respiratory Medicine, Nagoya University Graduate School of Medicine, Nagoya 466-8550 (Japan); Furuya, Kishio [Mechanobiology Laboratory, Nagoya University Graduate School of Medicine, Nagoya 466-8550 (Japan); Takahara, Norihiro [Department of Respiratory Medicine, Nagoya University Graduate School of Medicine, Nagoya 466-8550 (Japan); Naruse, Keiji [Department of Cardiovascular Physiology, Okayama University Graduate School of Medicine, Okayama 700-8558 (Japan); Aso, Hiromichi; Kondo, Masashi [Department of Respiratory Medicine, Nagoya University Graduate School of Medicine, Nagoya 466-8550 (Japan); Sokabe, Masahiro [Mechanobiology Laboratory, Nagoya University Graduate School of Medicine, Nagoya 466-8550 (Japan); Hasegawa, Yoshinori [Department of Respiratory Medicine, Nagoya University Graduate School of Medicine, Nagoya 466-8550 (Japan)

    2014-10-10

    Highlights: • Uniaxial stretching activates Ca{sup 2+} signaling in human lung fibroblasts. • Stretch-induced intracellular Ca{sup 2+} elevation is mainly via Ca{sup 2+} influx. • Mechanical strain enhances ATP release from fibroblasts. • Stretch-induced Ca{sup 2+} influx is not mediated by released ATP or actin cytoskeleton. - Abstract: One cause of progressive pulmonary fibrosis is dysregulated wound healing after lung inflammation or damage in patients with idiopathic pulmonary fibrosis and severe acute respiratory distress syndrome. The mechanical forces are considered to regulate pulmonary fibrosis via activation of lung fibroblasts. In this study, the effects of mechanical stretch on the intracellular Ca{sup 2+} concentration ([Ca{sup 2+}]{sub i}) and ATP release were investigated in primary human lung fibroblasts. Uniaxial stretch (10–30% in strain) was applied to fibroblasts cultured in a silicone chamber coated with type I collagen using a stretching apparatus. Following stretching and subsequent unloading, [Ca{sup 2+}]{sub i} transiently increased in a strain-dependent manner. Hypotonic stress, which causes plasma membrane stretching, also transiently increased the [Ca{sup 2+}]{sub i}. The stretch-induced [Ca{sup 2+}]{sub i} elevation was attenuated in Ca{sup 2+}-free solution. In contrast, the increase of [Ca{sup 2+}]{sub i} by a 20% stretch was not inhibited by the inhibitor of stretch-activated channels GsMTx-4, Gd{sup 3+}, ruthenium red, or cytochalasin D. Cyclic stretching induced significant ATP releases from fibroblasts. However, the stretch-induced [Ca{sup 2+}]{sub i} elevation was not inhibited by ATP diphosphohydrolase apyrase or a purinergic receptor antagonist suramin. Taken together, mechanical stretch induces Ca{sup 2+} influx independently of conventional stretch-sensitive ion channels, the actin cytoskeleton, and released ATP.

  8. Soleus stretch reflex during cycling

    DEFF Research Database (Denmark)

    Grey, Michael James; Pierce, C. W.; Milner, T. E.

    2001-01-01

    the crank cycle, producing ankle dorsiflexion perturbations of similar trajectory. The stretch reflex was greatest during the power phase of the crank cycle and was decreased to the level of background EMG during recovery. Matched perturbations were induced under static conditions at the same crank angle...... active cycling as has been shown with the H-reflex. This lack of depression may reflect a decreased susceptibility of the stretch reflex to inhibition, possibly originating from presynaptic mechanisms....

  9. Relationship Between Stretch Duration And Shoulder Musculature ...

    African Journals Online (AJOL)

    To date, studies focussing on the effect of stretching on flexibility have focused almost solely on the effect of chronic stretching rather than the effects of acute stretching performed immediately prior to physical activity. The effects of different static stretches were assessed on passive shoulder range of motion (ROM).

  10. Connecting Fundamental Constants

    International Nuclear Information System (INIS)

    Di Mario, D.

    2008-01-01

    A model for a black hole electron is built from three basic constants only: h, c and G. The result is a description of the electron with its mass and charge. The nature of this black hole seems to fit the properties of the Planck particle and new relationships among basic constants are possible. The time dilation factor in a black hole associated with a variable gravitational field would appear to us as a charge; on the other hand the Planck time is acting as a time gap drastically limiting what we are able to measure and its dimension will appear in some quantities. This is why the Planck time is numerically very close to the gravitational/electric force ratio in an electron: its difference, disregarding a π√(2) factor, is only 0.2%. This is not a coincidence, it is always the same particle and the small difference is between a rotating and a non-rotating particle. The determination of its rotational speed yields accurate numbers for many quantities, including the fine structure constant and the electron magnetic moment

  11. Self-consistent calculation of the weak constants in the parity nonconserving nuclear forces. Effective PNC hamiltonian in SU(2)sub(L)xU(1)xSU(3)sub(c). PNC in the πNN vertex

    International Nuclear Information System (INIS)

    Dubovik, V.M.; Zenkin, S.V.

    1983-01-01

    On the basis of the total effective Hamiltonian of the parity nonconserving (PNC) hadron-hadron interactions found within the standard model SU(2)sUb(L)XU(1)xSU(3)sub(c) in all orders of the leading logarithms allowing for the difference of quark mass scales (msub(c)>>msub(u, d, s)) the PNC πNN vertex generating the long-range part of the PNC nuclear forces is considered. The origin and the methods of calculation of various contributions to this vertex with a special attention to possible artifacts of these methods is anatyzed. Within the self-consistence calculational framework partly including the MIT bag model the total value of the constant hsub(π) determining the PNC πNN vertex is evaluated. Value of hsub(π) (approximately 1.3x10 -7 ) is 2-4 times as small as previous estimates and does not contradict the experimental data

  12. Atomic Stretch: Optimally bounded real-time stretching and beyond

    DEFF Research Database (Denmark)

    Jensen, Rasmus Ramsbøl; Nielsen, Jannik Boll

    2016-01-01

    Atomic Stretch is a plugin for your preferred Adobe video editing tool, allowing real-time smooth and optimally bounded retarget-ting from and to any aspect ratio. The plugin allows preserving of high interest pixels through a protected region, attention redirection through color-modification, co......Atomic Stretch is a plugin for your preferred Adobe video editing tool, allowing real-time smooth and optimally bounded retarget-ting from and to any aspect ratio. The plugin allows preserving of high interest pixels through a protected region, attention redirection through color...

  13. Static stretching does not alter pre and post-landing muscle activation

    Directory of Open Access Journals (Sweden)

    Moss Wesley R

    2011-05-01

    Full Text Available Abstract Background Static stretching may result in various strength and power deficiencies. Prior research has not determined, however, if static stretching causes a change in muscle activation during a functional task requiring dynamic stability. The purpose of this study was to determine if static stretching has an effect on mean pre and postlanding muscle (vastus medialis VM, vastus lateralis VL, medial hamstring MH, and biceps femoris BF activity. Methods 26 healthy, physically active subjects were recruited, from which 13 completed a 14-day static stretching regimen for the quadriceps and hamstrings. Using the data from the force plate and EMG readings, a mean of EMG amplitude was calculated for 150 msec before and after landing. Each trial was normalized to an isometric reference position. Means were calculated for the VM, VL, MH, and BF from 5 trials in each session. Measures were collected pre, immediately following the 1st stretching session, and following 2 weeks of stretching. Results A 14-day static stretching regimen resulted in no significant differences in pre or postlanding mean EMG amplitude during a drop landing either acutely or over a 14-day period. Conclusions Static stretching, done acutely or over a 14-day period does not result in measurable differences of mean EMG amplitude during a drop landing. Static stretching may not impede dynamic stability of joints about which stretched muscles cross.

  14. Analyzing Forced Unfolding of Protein Tandems by Ordered Variates, 1: Independent Unfolding Times

    Science.gov (United States)

    Bura, E.; Klimov, D. K.; Barsegov, V.

    2007-01-01

    Most of the mechanically active proteins are organized into tandems of identical repeats, (D)N, or heterogeneous tandems, D1–D2–…–DN. In current atomic force microscopy experiments, conformational transitions of protein tandems can be accessed by employing constant stretching force f (force-clamp) and by analyzing the recorded unfolding times of individual domains. Analysis of unfolding data for homogeneous tandems relies on the assumption that unfolding times are independent and identically distributed, and involves inference of the (parent) probability density of unfolding times from the histogram of the combined unfolding times. This procedure cannot be used to describe tandems characterized by interdomain interactions, or heteregoneous tandems. In this article, we introduce an alternative approach that is based on recognizing that the observed data are ordered, i.e., first, second, third, etc., unfolding times. The approach is exemplified through the analysis of unfolding times for a computer model of the homogeneous and heterogeneous tandems, subjected to constant force. We show that, in the experimentally accessible range of stretching forces, the independent and identically distributed assumption may not hold. Specifically, the uncorrelated unfolding transitions of individual domains at lower force may become correlated (dependent) at elevated force levels. The proposed formalism can be used in atomic force microscopy experiments to infer the unfolding time distributions of individual domains from experimental histograms of ordered unfolding times, and it can be extended to analyzing protein tandems that exhibit interdomain interactions. PMID:17496033

  15. Soleus stretch reflex during cycling

    DEFF Research Database (Denmark)

    Grey, Michael James; Pierce, C. W.; Milner, T. E.

    2001-01-01

    The modulation and strength of the human soleus short latency stretch reflex was investigated by mechanically perturbing the ankle during an unconstrained pedaling task. Eight subjects pedaled at 60 rpm against a preload of 10 Nm. A torque pulse was applied to the crank at various positions durin...

  16. On the generalised stretch function

    Czech Academy of Sciences Publication Activity Database

    Kharlamov, Alexander A.; Filip, Petr

    2012-01-01

    Roč. 21, č. 4 (2012), s. 272-278 ISSN 1022-1344 R&D Projects: GA ČR GA103/09/2066 Institutional research plan: CEZ:AV0Z20600510 Keywords : molecular length * recurrence equations * rubber * strain * stretch functions Subject RIV: BK - Fluid Dynamics Impact factor: 1.606, year: 2012

  17. Optical tweezers stretching of chromatin

    NARCIS (Netherlands)

    Pope, L.H.; Bennink, Martin L.; Greve, Jan

    2003-01-01

    Recently significant success has emerged from exciting research involving chromatin stretching using optical tweezers. These experiments, in which a single chromatin fibre is attached by one end to a micron-sized bead held in an optical trap and to a solid surface or second bead via the other end,

  18. Transient filament stretching rheometer II

    DEFF Research Database (Denmark)

    Kolte, Mette Irene; Rasmussen, Henrik K.; Hassager, Ole

    1997-01-01

    The Lagrangian sspecification is used to simulate the transient stretching filament rheometer. Simulations are performed for dilute PIB-solutions modeled as a four mode Oldroyd-B fluid and a semidilute PIB-solution modeled as a non-linear single integral equation. The simulations are compared...

  19. Biaxial stretching of polyethylene, (2)

    International Nuclear Information System (INIS)

    Sakami, Hiroshi; Iida, Shozo

    1976-01-01

    The mechanism of oriented crystallization in mutually perpendicular direction to each other was investigated on the crosslinked linear polyethylene stretched successively and biaxially above melting point of raw material. To investigate the mechanism, the shrinkage stress, the degree of polarization and DSC of the film at the fixed length were measured on the crystallization process. The behavior observed on crystallization could be divided into that in the first period and that in the second period. The first period showed the domain of highly oriented crystallization of the crosslinked molecular chain, and in the second period the fold type crystals grew with highly oriented crystals in the first period as nuclear. Therefore, the formation of bi-component crystal structure is supposed for the crystallization. The biaxially oriented crystallization proceeded as follows: the uniaxial orientation to MD was observed in the first stretching in the initial stage, and then the further processing by the second stretching at a right angle caused the fold type crystallization of molecular chain oriented to TD. The film stretched fully and biaxially could be considered to have the oriented crystalline structure in which highly oriented fibril crystals and fold type crystals distribute at random. (auth.)

  20. Device for stretching tapes or cables intended for manipulators

    International Nuclear Information System (INIS)

    Baudoin, J.-C.; Oger, Robert.

    1975-01-01

    The invention relates to a device for stretching tapes (or cables) intended for remote handling devices. Said equipment consists of a spring system continuously applying a constant tensile stress to said tapes (or cables) in view of taking up the slack in the latter. Said spring system is fastened to a supporting bar able to be rigidly connected to a member of the remote handling device [fr

  1. Effect of hexane treatment and uniaxial stretching on bending ...

    African Journals Online (AJOL)

    ... β31, defined as the bending piezoelectric stress constant, was calculated. After hexane treatment and uniaxial stretching of the PVDF film, the value of β31 was 5.75 mV/m and 8.00 mV/m for draw ratio of 1.5 and 2.5 was recorded. Fourier transform Infra-red (FTIR) spectrophotometry was used for structural investigations.

  2. Cyclic Stretch Alters Vascular Reactivity of Mouse Aortic Segments

    Directory of Open Access Journals (Sweden)

    Arthur Leloup

    2017-10-01

    Full Text Available Large, elastic arteries buffer the pressure wave originating in the left ventricle and are constantly exposed to higher amplitudes of cyclic stretch (10% than muscular arteries (2%. As a crucial factor for endothelial and smooth muscle cell function, cyclic stretch has, however, never been studied in ex vivo aortic segments of mice. To investigate the effects of cyclic stretch on vaso-reactivity of mouse aortic segments, we used the Rodent Oscillatory Tension Set-up to study Arterial Compliance (ROTSAC. The aortic segments were clamped at frequencies of 6–600 bpm between two variable preloads, thereby mimicking dilation as upon left ventricular systole and recoiling as during diastole. The preloads corresponding to different transmural pressures were chosen to correspond to a low, normal or high amplitude of cyclic stretch. At different time intervals, cyclic stretch was interrupted, the segments were afterloaded and isometric contractions by α1-adrenergic stimulation with 2 μM phenylephrine in the absence and presence of 300 μM L-NAME (eNOS inhibitor and/or 35 μM diltiazem (blocker of voltage-gated Ca2+ channels were measured. As compared with static or cyclic stretch at low amplitude (<10 mN or low frequency (0.1 Hz, cyclic stretch at physiological amplitude (>10 mN and frequency (1–10 Hz caused better ex vivo conservation of basal NO release with time after mounting. The relaxation of PE-precontracted segments by addition of ACh to stimulate NO release was unaffected by cyclic stretch. In the absence of basal NO release (hence, presence of L-NAME, physiological in comparison with aberrant cyclic stretch decreased the baseline tension, attenuated the phasic contraction by phenylephrine in the absence of extracellular Ca2+ and shifted the smaller tonic contraction more from a voltage-gated Ca2+ channel-mediated to a non-selective cation channel-mediated. Data highlight the need of sufficient mechanical activation of endothelial and

  3. Measurement of skin stretch using digital image speckle correlation.

    Science.gov (United States)

    Staloff, Isabelle Afriat; Rafailovitch, Miriam

    2008-08-01

    The surface of the skin is covered by intersecting grooves and ridges which produce characteristic skin surface patterns. It has been suggested that these folds provide a reserve of tissue, allowing the skin to stretch during normal muscle movements. More so, skin is anisotropic and under constant tension. Therefore, to characterize skin displacement following stretch, a discrete, description of the in-plane skin displacement during stretch is of interest. We introduce the use of digital image speckle correlation (DISC), a non-contact technique, to map, in two dimensions, the surface deformation patterns resulting from skin stretching. We analyze skin stretch under the mechanical action of a film former applied on a defined square surface on the back of the hand. This is achieved by taking a series of images, during the drying process of the film former. The images are then analyzed with DISC to create vector diagram and projection maps, from which we can obtain spatially resolved information regarding the skin displacement. We first show that DISC can provide spatially resolved information at any time point during the drying process: areas of de-wetting, wetting were identified using projection maps; we then extracted the value of the drying time. Finally using a vector map, we show the orientation of the skin displacement during stretching and calculated the magnitude of the total stretch. We have shown previously that DISC can be used to determine skin mechanical properties and muscular activity. We show here that DISC, as a non-contact technique, can map, in two dimensions, the surface deformation patterns of a polymer solution on a substrate at any time point during the drying process. DISC analysis generates for each speckle of the sample analyzed, the orientation and magnitude of displacement of the polymer solution. DISC can map in two dimensions the deformation undergone by the substrate and skin stretch is measured in this particular case. We therefore

  4. Reflectors Made from Membranes Stretched Between Beams

    Science.gov (United States)

    Dooley, Jennifer; Dragovan, Mark; Tolomeo, Jason

    2009-01-01

    Lightweight cylindrical reflectors of a proposed type would be made from reflective membranes stretched between pairs of identically curved and identically oriented end rails. In each such reflector, the curvature of the two beams would define the reflector shape required for the intended application. For example, the beams could be curved to define a reflector of parabolic cross section, so that light incident along the axis of symmetry perpendicular to the cylindrical axis would be focused to a line. In addition, by applying suitable forces to the ends of the beams, one could bend the beams to adjust the reflector surface figure to within a precision of the order of the wavelength of the radiation to be reflected. The figure depicts an example of beams shaped so that in the absence of applied forces, each would be flat on one side and would have a radius of curvature R on the opposite side. Alternatively, the curvature of the reflector-membrane side could be other than circular. In general, the initial curvature would be chosen to optimize the final reflector shape. Then by applying forces F between the beam ends in the positions and orientations shown in the figure, one could bend beams to adjust their shape to a closer approximation of the desired precise circular or noncircular curvature.

  5. Acute effects of passive stretching of the plantarflexor muscles on neuromuscular function: the influence of age.

    Science.gov (United States)

    Ryan, Eric D; Herda, Trent J; Costa, Pablo B; Herda, Ashley A; Cramer, Joel T

    2014-01-01

    The acute effects of stretching on peak force (Fpeak), percent voluntary activation (%VA), electromyographic (EMG) amplitude, maximum range of motion (MROM), peak passive torque, the passive resistance to stretch, and the percentage of ROM at EMG onset (%EMGonset) were examined in 18 young and 19 old men. Participants performed a MROM assessment and a maximal voluntary contraction of the plantarflexors before and immediately after 20 min of passive stretching. Fpeak (-11 %), %VA (-6 %), and MG EMG amplitude (-9 %) decreased after stretching in the young, but not the old (P > 0.05). Changes in Fpeak were related to reductions in all muscle activation variables (r = 0.56-0.75), but unrelated to changes in the passive resistance to stretch (P ≥ 0.24). Both groups experienced increases in MROM and peak passive torque and decreases in the passive resistance to stretch. However, the old men experienced greater changes in MROM (P stretching for both groups (P = 0.213), but occurred earlier in the old (P = 0.06). The stretching-induced impairments in strength and activation in the young but not the old men may suggest that the neural impairments following stretching are gamma-loop-mediated. In addition, the augmented changes in MROM and passive torque and the lack of change in %EMGonset for the old men may be a result of age-related changes in muscle-tendon behavior.

  6. Photothermal cantilever actuation for fast single-molecule force spectroscopy

    Science.gov (United States)

    Stahl, Stefan W.; Puchner, Elias M.; Gaub, Hermann E.

    2009-07-01

    Photothermal cantilever excitation provides a fast and easy to implement means to control the deflection of standard atomic force microscopy cantilevers. Minute heat pulses yield deflections on the order of several tens of nanometers or when the deflection is kept constant, forces of several hundreds of piconewton can be applied. In our case these pulses resulted in less than 1 K temperature changes at the sample position. Here we present and characterize the implementation of photothermal actuation for single-molecule force-spectroscopy experiments. When molecules are stretched under force-clamp conditions, fast control cycles that re-establish the pulling force after the rupture of molecular domains are essential for detecting the complete unfolding pattern with high precision. By combining the fast response of photothermal cantilever excitation with a conventional piezoactuator, a fast force-clamp with high accuracy and large working distances is reached. Simple feedback mechanisms and standard cantilever geometries lead to step response times of less than 90 μs, which is more than one order of magnitude faster than those of conventional force-clamp systems that are based only on piezo feedback. We demonstrate the fast and accurate performance of the setup by unfolding a protein construct consisting of one green fluorescent protein and eight surrounding immunoglobulin domains at constant force.

  7. Time stretch and its applications

    Science.gov (United States)

    Mahjoubfar, Ata; Churkin, Dmitry V.; Barland, Stéphane; Broderick, Neil; Turitsyn, Sergei K.; Jalali, Bahram

    2017-06-01

    Observing non-repetitive and statistically rare signals that occur on short timescales requires fast real-time measurements that exceed the speed, precision and record length of conventional digitizers. Photonic time stretch is a data acquisition method that overcomes the speed limitations of electronic digitizers and enables continuous ultrafast single-shot spectroscopy, imaging, reflectometry, terahertz and other measurements at refresh rates reaching billions of frames per second with non-stop recording spanning trillions of consecutive frames. The technology has opened a new frontier in measurement science unveiling transient phenomena in nonlinear dynamics such as optical rogue waves and soliton molecules, and in relativistic electron bunching. It has also created a new class of instruments that have been integrated with artificial intelligence for sensing and biomedical diagnostics. We review the fundamental principles and applications of this emerging field for continuous phase and amplitude characterization at extremely high repetition rates via time-stretch spectral interferometry.

  8. Upper Limb Static-Stretching Protocol Decreases Maximal Concentric Jump Performance

    Directory of Open Access Journals (Sweden)

    Paulo H. Marchetti

    2014-12-01

    Full Text Available The purpose of the present study was to evaluate the acute effects of an upper limb static-stretching (SS protocol on the maximal concentric jump performance. We recruited 25 young healthy, male, resistance trained individuals (stretched group, n = 15 and control group, n = 10 in this study. The randomized between group experimental protocol consisted of a three trials of maximal concentric jump task, before and after a SS of the upper limb. Vertical ground reaction forces (vGRF and surface electromyography (sEMG of both gastrocnemius lateralis (GL and vastus lateralis (VL were acquired. An extensive SS was employed consisting of ten stretches of 30 seconds, with 15 seconds of rest, and 70-90% of the point of discomfort (POD. ANOVA (2x2 (group x condition was used for shoulder joint range of motion (ROM, vGRF and sEMG. A significant interaction for passive ROM of the shoulder joint revealed significant increases between pre- and post-SS protocol (p < 0.001. A significant interaction demonstrated decreased peak force and an increased peak propulsion duration between pre- and post-stretching only for stretch group (p = 0.021, and p = 0.024, respectively. There was a significant main effect between groups (stretch and control for peak force for control group (p = 0.045. Regarding sEMG variables, there were no significant differences between groups (control versus stretched or condition (pre-stretching versus post-stretching for the peak amplitude of RMS and IEMG for both muscles (VL and GL. In conclusion, an acute extensive SS can increase the shoulder ROM, and negatively affect both the propulsion duration and peak force of the maximal concentric jump, without providing significant changes in muscle activation.

  9. Measurement of Material Functions in Extensional Flow Using the Filament Stretch Rheometer

    DEFF Research Database (Denmark)

    Rasmussen, Henrik K.; Nielsen, Jens Kromann; Laille, Philippe

    2007-01-01

    The measurement of material functions other than startup and steady viscosity is demonstrated using the Filament Stretching Rheometer. This includes startup of uniaxial elongational flow (potentially until steady state) followed by stress relaxation, large amplitude oscillatory elongational flow ...... imposed upon a constant strain rate uni axial elongation and startup of uniaxial elongational flow followed by biaxial squeezing. The used Filament Stretching Rheometer allows measurements on polymeric fluids (including polymeric melts) from room temperatures until 200°C....

  10. Post-activation depression of soleus stretch reflexes in healthy and spastic humans

    DEFF Research Database (Denmark)

    Grey, Michael James; Klinge, Klaus; Crone, Clarissa

    2007-01-01

    delivered at different intervals. The magnitude of the stretch reflex and ankle torque response was assessed as a function of the time between perturbations. Soleus stretch reflexes were evoked with constant velocity (175 degrees /s) and amplitude (6 degrees ) plantar flexion perturbations. Soleus H......-reflexes were evoked by electrical stimulation of the tibial nerve in the popliteal fossa. The stretch reflex and H-reflex responses of 30 spastic participants (with multiple sclerosis or spinal cord injury) were compared with those of 15 healthy participants. In the healthy participants, the magnitude...

  11. Stretching

    Science.gov (United States)

    ... this topic for: Teens Dehydration Safety Tips: Running Knee Injuries Repetitive Stress Injuries Sports and Exercise Safety Dealing With Sports Injuries Sports Center Strains and Sprains View more Partner Message About Us Contact Us ...

  12. Crustal Stretching Style and Lower Crust Flow of the South China Sea Northern Margin

    Science.gov (United States)

    Bai, Y.; Dong, D.; Runlin, D.

    2017-12-01

    There is a controversy about crustal stretching style of the South China Sea (SCS) northern margin mainly due to considerable uncertainty of stretching factor estimation, for example, as much as 40% of upper crust extension (Walsh et al., 1991) would be lost by seismic profiles due to poor resolution. To discover and understand crustal stretching style and lower crustal flow on the whole, we map the Moho and Conrad geometries based on gravity inversion constrained by deep seismic profiles, then according to the assumption of upper and lower crust initial thickness, upper and lower crust stretching factors are estimated. According to the comparison between upper and lower crust stretching factors, the SCS northern margin could be segmented into three parts, (1) sediment basins where upper crust is stretched more than lower crust, (2) COT regions where lower crust is stretched more than upper crust, (3) other regions where the two layers have similar stretching factors. Stretching factor map shows that lower crust flow happened in both of COT and sediment basin regions where upper crust decouples with lower crust due to high temperature. Pressure contrast by sediment loading in basins and erosion in sediment-source regions will lead to lower crust flow away from sediment sink to source. Decoupled and fractured upper crust is stretched further by sediment loading and the following compensation would result in relatively thick lower crust than upper crust. In COT regions with thin sediment coverage, low-viscosity lower crust is easier to thin in extensional environment, also the lower crust tends to flow away induced by magma upwelling. Therefore, continental crust on the margin is not stretching in a constant way but varies with the tectonic setting changes. This work is supported by National Natural Science Foundation of China (Grant No. 41506055, 41476042) and Fundamental Research Funds for the Central Universities China (No.17CX02003A).

  13. A study of viscoelasticity index for evaluating muscle hypotonicity during static stretching.

    Science.gov (United States)

    Okamura, Naomi; Tsukune, Mariko; Kobayashi, Yo; Fujie, Masakatsu G

    2014-01-01

    Static stretching is widely used as a preventative treatment for musculoskeletal disabilities by providing muscle hypotonicity, which results from changes in muscle tissue structure. However, the quantitative evaluation of hypotonicity during stretching has had limited success owing to the confounding factor of mechanical stress relaxation. To resolve this problem, we propose a new evaluation method for hypotonicity based on a viscoelastic muscle model using fractional calculus, which is known to be effective for biomaterials. We made continuous measurements of rectus skin indentation during static stretching as an indicator of reaction force in the rectus femoris muscle. The viscoelastic ratio and modulus were computed from the indentation trace. Both viscoelastic parameters decreased significantly between the early and final phases of stretching. The results suggest that our method is useful for quantitative evaluation of muscle hypotonicity during stretching.

  14. Physics-based side-chain-rotamer and side-chain and backbone virtual-bond-stretching potentials for coarse-grained UNRES force field. 2. Comparison with statistical potentials and implementation

    Science.gov (United States)

    Kozłowska, Urszula; Maisuradze, Gia G.; Liwo, Adam; Scheraga, Harold A.

    2009-01-01

    Using the harmonic-approximation approach of the accompanying paper and AM1 energy surfaces of terminally-blocked amino-acid residues, we determined physics-based side-chain-rotamer potentials and the side-chain virtual-bond-deformation potentials of 19 natural amino-acid residues with side chains. The potentials were approximated by analytical formulas and implemented in the UNRES mesoscopic dynamics program. For comparison, the corresponding statistical potentials were determined from 19,682 high-resolution protein structures. The low-free-energy region of both the AM1-derived and the statistical potentials is determined by the valence geometry and the L-chirality, and its size increases with side-chain flexibility and decreases with increasing virtual-bond-angle θ. The differences between the free energies of rotamers are greater for the AM1-derived potentials compared to the statistical potentials and, for alanine and other residues with small side chains, a region corresponding to the Cax7 conformation has remarkably low free energy for the AM1-derived potentials, as opposed to the statistical potentials. These differences probably result from the interactions between neighboring residues and indicate the need for introduction of cooperative terms accounting for the coupling between side-chain-rotamer and backbone interactions. Both AM1-derived and statistical virtual-bond-deformation potentials are multimodal for flexible side chains and are topologically similar; however, the regions of minima of the statistical potentials are much narrower, which probably results from imposing restraints in structure determination. The force field with the new potentials was preliminarily optimized using the FBP WW domain (1E0L) and the engrailed homeodomain (1ENH) as training proteins and assessed to be reasonably transferable. PMID:20017135

  15. Effect of stretching techniques on hamstring flexibility in female ...

    African Journals Online (AJOL)

    Flexibility can be achieved by a variety of stretching techniques and the benefits of stretching are known. However, controversy remains about the best type of stretching for achieving a particular goal or outcome. The four most basic stretches are static stretching, dynamic stretching, PNF hold-relax and PNF contract-relax ...

  16. Bending and stretching of plates

    CERN Document Server

    Mansfield, E H; Hemp, W S

    1964-01-01

    The Bending and Stretching of Plates deals with elastic plate theory, particularly on small- and large-deflexion theory. Small-deflexion theory concerns derivation of basic equations, rectangular plates, plates of various shapes, plates whose boundaries are amenable to conformal transformation, plates with variable rigidity, and approximate methods. Large-deflexion theory includes general equations and some exact solutions, approximate methods in large-deflexion theory, asymptotic large-deflexion theories for very thin plates. Asymptotic theories covers membrane theory, tension field theory, a

  17. Stretching of macromolecules and proteins

    International Nuclear Information System (INIS)

    Strick, T R; Dessinges, M-N; Charvin, G; Dekker, N H; Allemand, J-F; Bensimon, D; Croquette, V

    2003-01-01

    In this paper we review the biophysics revealed by stretching single biopolymers. During the last decade various techniques have emerged allowing micromanipulation of single molecules and simultaneous measurements of their elasticity. Using such techniques, it has been possible to investigate some of the interactions playing a role in biology. We shall first review the simplest case of a non-interacting polymer and then present the structural transitions in DNA, RNA and proteins that have been studied by single-molecule techniques. We shall explain how these techniques permit a new approach to the protein folding/unfolding transition

  18. Ion exchange equilibrium constants

    CERN Document Server

    Marcus, Y

    2013-01-01

    Ion Exchange Equilibrium Constants focuses on the test-compilation of equilibrium constants for ion exchange reactions. The book first underscores the scope of the compilation, equilibrium constants, symbols used, and arrangement of the table. The manuscript then presents the table of equilibrium constants, including polystyrene sulfonate cation exchanger, polyacrylate cation exchanger, polymethacrylate cation exchanger, polysterene phosphate cation exchanger, and zirconium phosphate cation exchanger. The text highlights zirconium oxide anion exchanger, zeolite type 13Y cation exchanger, and

  19. PROPRIOCEPTIVE NEUROMUSCULAR FACILITATION STRETCHING VERSUS STATIC STRETCHING ON SPRINTING PERFORMANCE AMONG COLLEGIATE SPRINTERS

    Directory of Open Access Journals (Sweden)

    Jayaram Maharjan

    2015-08-01

    Full Text Available Background: A warm-up is important part of preparation for sprinting. There is popularity of doing stretching as part of warm up before athletic activity. The static stretching and PNF stretching is performed by athletes but their effectiveness on sprinting performance is in state of debate. The objective is to determine the effect of static stretching and PNF stretching on sprinting performance in college sprinters and to compare the effects of PNF stretching over static stretching on sprinting performance in college sprinters. Method: A total of 100 subjects were taken for the study that fulfill the inclusion criteria and all were divided into group- A (static stretching and group- B (PNF stretching by simple random sampling method. Both the groups received 5 minutes of warm-up exercises. Pre-Post design was used, which consisted of running a 40-yard sprint immediately following 2 stretching conditions aimed at the lower limb muscles Results: In static stretching group sprint time changed from 6.55 with standard deviation of 0.93 to 6.12 with standard deviation of 1.02 (P.605. Conclusion: Hence both static stretching and PNF stretching can be performed before sprinting activity to improve the sprinting performance.

  20. Stretched versus compressed exponential kinetics in α-helix folding

    International Nuclear Information System (INIS)

    Hamm, Peter; Helbing, Jan; Bredenbeck, Jens

    2006-01-01

    In a recent paper (J. Bredenbeck, J. Helbing, J.R. Kumita, G.A. Woolley, P. Hamm, α-helix formation in a photoswitchable peptide tracked from picoseconds to microseconds by time resolved IR spectroscopy, Proc. Natl. Acad. Sci USA 102 (2005) 2379), we have investigated the folding of a photo-switchable α-helix with a kinetics that could be fit by a stretched exponential function exp(-(t/τ) β ). The stretching factor β became smaller as the temperature was lowered, a result which has been interpreted in terms of activated diffusion on a rugged energy surface. In the present paper, we discuss under which conditions diffusion problems occur with stretched exponential kinetics (β 1). We show that diffusion problems do have a strong tendency to yield stretched exponential kinetics, yet, that there are conditions (strong perturbation from equilibrium, performing the experiment in the folding direction) under which compressed exponential kinetics would be expected instead. We discuss the kinetics on free energy surfaces predicted by simple initiation-propagation models (zipper models) of α-helix folding, as well as by folding funnel models. We show that our recent experiment has been performed under condition for which models with strong downhill driving force, such as the zipper model, would predict compressed, rather than stretched exponential kinetics, in disagreement with the experimental observation. We therefore propose that the free energy surface along a reaction coordinate that governs the folding kinetics must be relatively flat and has a shape similar to a 1D golf course. We discuss how this conclusion can be unified with the thermodynamically well established zipper model by introducing an additional kinetic reaction coordinate

  1. Contact angles on stretched solids

    Science.gov (United States)

    Mensink, Liz; Snoeijer, Jacco

    2017-11-01

    The surface energy of solid interfaces plays a central role in wetting, as they dictate the liquid contact angle. Yet, it has been challenging to measure the solid surface energies independently, without making use of Young's law. Here we present Molecular Dynamics (MD) simulations by which we measure the surface properties for all interfaces, including the solids. We observe change in contact angles upon stretching the solid substrates, showing that the surface energy is actually strain dependent. This is clear evidence of the so-called Shuttleworth effect, making it necessary to distinguish surface energy from surface tension. We discuss how this effect gives rise to a new class of elasto-capillary phenomena. ERC Consolidator Grant No. 616918.

  2. A COMPARISION BETWEEN CROSSBODY STRETCH VERSUS SLEEPER STRETCH IN PERIARTHRITIS OF SHOULDER

    Directory of Open Access Journals (Sweden)

    Shaik Raheem Saheb

    2015-12-01

    Full Text Available Background: Recently Cross body stretch and Sleeper stretch are used to improve internal rotation Range of motion in Shoulder Pathologies. It was proposed to study the effect of cross body stretch and sleeper stretch in subjects with periarthritis of shoulder. Methods: 60 subjects with a mean age of 53 years having clinical diagnosis of Periarthritis of shoulder and full filled the inclusive criteria are taken. After the initial measurements, the subjects are randomly assigned into 2 stretching groups. Group-A performed the Sleeper stretch. Group-B performed a Cross body stretch. Both Groups performed the Stretch in Duration of 6weeks – once daily for 5 repetitions holding each stretch for 30 seconds for 5 days a week. Along with this technique conventional physiotherapy like IFT, overhead pulleys, Pendula exercises, Wall climbing exercises, mariners wheel exercises are performed. After the treatment, subjects were evaluated for their pain profile using visual analogue scale, Goniometer for measuring Range of motion. Results: For within group comparison we used Paired t-test analysis, For Between group comparison we used Independent t-test for statistical analysis. At the end of 6 weeks It was found that subjects treated with cross-body stretch showed significant improvement in terms of VAS scores and Range of motion scores (P=0.000 and patients treated with Sleeper stretch showed significant improvement in terms of VAS scores and Range of motion scores (P=0.000. When compared between Groups the VAS and Range of motion scores showed a significant improvement in Cross body stretch Group than the Sleeper stretch Group (P=0.000. Conclusion: It was concluded that both stretching techniques were found improvement in Range of motion and VAS and Cross-body Stretch showed more Significant improvement than the sleeper Stretch after 6 weeks treatment.

  3. Anharmonic Bend-Stretch Coupling in Water

    NARCIS (Netherlands)

    Lindner, Jörg; Vöhringer, Peter; Pshenichnikov, Maxim S.; Cringus, Dan; Wiersma, Douwe A.; Corkum, Paul; Jonas, David M.; Miller, R.J. Dwayne.; Weiner, Andrew M.

    2006-01-01

    Following excitation of the H-O-H bending mode of water molecules in solution the stretching mode region is monitored over its entire width. The anharmonic coupling between the two modes results in a substantial change of the transient stretch absorption that decays with the bend depopulation time.

  4. Retinal glial (Müller ) cells: sensing and responding to tissue stretch.

    Science.gov (United States)

    Lindqvist, Niclas; Liu, Qing; Zajadacz, Joachim; Franze, Kristian; Reichenbach, Andreas

    2010-03-01

    To test whether Müller glial cells sense, and respond to, mechanical tension in the retina. A device was designed to stretch the retina at right angles to its surface, across retinal layers. Pieces of retina were mounted between two hollow tubes, and uniaxial force was applied to the tissue using a micrometer-stepping motor. Müller cells were selectively stained with the fluorescent, calcium-sensitive dye X-Rhod-1 and were monitored in real time during retinal stretch in vitro. Immunohistochemistry was used to study protein levels and activation of intracellular pathways in stretched retinas. Müller cells responded acutely with transient increases in fluorescence during stretch, indicative of increased intracellular calcium levels. All the Müller cells elongated uniformly, and there was no apparent difference between retinal layers in resistance against mechanical deformation. After stretch, Müller cells showed fast activation of extracellular signal-regulated kinase (after 15 minutes), upregulation of transcription factor c-Fos (after 1 hour), and basic fibroblast growth factor (after 3 hours). No changes in intermediate filament protein expression were observed in Müller cells up to 3 hours after stretch. A novel technique was developed for real-time monitoring of Müller cells during retinal stretch, which allowed the identification of Müller cells as a mechanoresponsive cell type. Mechanical stress triggers molecular responses in Müller cells that could prevent retinal damage.

  5. Effects of Plantar Flexor Muscle Static Stretching Alone and Combined With Massage on Postural Balance.

    Science.gov (United States)

    Hemmati, Ladan; Rojhani-Shirazi, Zahra; Ebrahimi, Samaneh

    2016-10-01

    To evaluate and compare the effects of stretching and combined therapy (stretching and massage) on postural balance in people aged 50 to 65 years. Twenty-three subjects participated in this nonrandomized clinical trial study. Each participant randomly received plantar flexor muscle stretching (3 cycles of 45 seconds with a 30-second recovery period between cycles) alone and in combination with deep stroking massage (an interval of at least 30 minutes separated the two interventions). The data were recorded with a force platform immediately after each condition with eyes open and closed. The center of pressure displacement and velocity along the mediolateral and anteroposterior axes were calculated under each condition. The data were analyzed with multiple-pair t-tests. The center of pressure displacement and velocity along the mediolateral axis increased after both stretching and the combined intervention. There were significant differences in both values between participants in the stretching and combined interventions (pmuscle stretching (for 45 seconds) combined with deep stroking massage may have more detrimental effects on postural balance than stretching alone because each intervention can intensify the effects of the other.

  6. Spectroscopic Constants and Vibrational Frequencies for l-C3H+ and Isotopologues from Highly-Accurate Quartic Force Fields: The Detection of l-C3H+ in the Horsehead Nebula PDR Questioned

    Science.gov (United States)

    Huang, Xinchuan; Fortenberry, Ryan Clifton; Lee, Timothy J.

    2013-01-01

    Very recently, molecular rotational transitions observed in the photon-dominated region of the Horsehead nebula have been attributed to l-C3H+. In an effort to corroborate this finding, we employed state-of-the art and proven high-accuracy quantum chemical techniques to compute spectroscopic constants for this cation and its isotopologues. Even though the B rotational constant from the fit of the observed spectrum and our computations agree to within 20 MHz, a typical level of accuracy, the D rotational constant differs by more than 40%, while the H rotational constant differs by three orders of magnitude. With the likely errors in the rotational transition energies resulting from this difference in D on the order of 1 MHz for the lowest observed transition (J = 4 yields 3) and growing as J increases, the assignment of the observed rotational lines from the Horsehead nebula to l-C3H+ is questionable.

  7. Extensional viscosity for polymer melts measured in the filament stretching rheometer

    DEFF Research Database (Denmark)

    Bach, Anders; Rasmussen, Henrik K.; Hassager, Ole

    2003-01-01

    A new filament stretching rheometer has been constructed to measure the elongational viscosity of polymer melts at high temperatures. Two polymer melts, a LDPE and a LLDPE, were investigated with this rheometer. A constant elongational rate has been obtained by an iterative application of the Orr...

  8. Uniaxial tension test on Rubber at constant true strain rate

    Directory of Open Access Journals (Sweden)

    Sourne H.L.

    2012-08-01

    Full Text Available Elastomers are widely used for damping parts in different industrial contexts because of their remarkable dissipation properties. Indeed, they can undergo severe mechanical loading conditions, i.e., high strain rates and large strains. Nevertheless, the mechanical response of these materials can vary from purely rubber-like to glassy depending on the strain rate undergone. Classically, uniaxial tension tests are made in order to find a relation between the stress and the strain in the material at various strain rates. However, even if the strain rate is searched to be constant, it is the nominal strain rate that is considered. Here we develop a test at constant true strain rate, i.e. the strain rate that is experienced by the material. In order to do such a test, the displacement imposed by the machine is an exponential function of time. This test has been performed with a high speed hydraulic machine for strain rates between 0.01/s and 100/s. A specific specimen has been designed, yielding a uniform strain field (and so a uniform stress field. Furthermore, an instrumented aluminum bar has been used to take into account dynamic effects in the measurement of the applied force. A high speed camera enables the determination of strain in the sample using point tracking technique. Using this method, the stress-strain curve of a rubber-like material during a loading-unloading cycle has been determined, up to a stretch ratio λ = 2.5. The influence of the true strain rate both on stiffness and on dissipation of the material is then discussed.

  9. The Fine Structure Constant

    Indian Academy of Sciences (India)

    IAS Admin

    The article discusses the importance of the fine structure constant in quantum mechanics, along with the brief history of how it emerged. Al- though Sommerfelds idea of elliptical orbits has been replaced by wave mechanics, the fine struc- ture constant he introduced has remained as an important parameter in the field of ...

  10. The Cosmological Constant

    Directory of Open Access Journals (Sweden)

    Carroll Sean M.

    2001-01-01

    Full Text Available This is a review of the physics and cosmology of the cosmological constant. Focusing on recent developments, I present a pedagogical overview of cosmology in the presence of a cosmological constant, observational constraints on its magnitude, and the physics of a small (and potentially nonzero vacuum energy.

  11. On Aryabhata's Planetary Constants

    OpenAIRE

    Kak, Subhash

    2001-01-01

    This paper examines the theory of a Babylonian origin of Aryabhata's planetary constants. It shows that Aryabhata's basic constant is closer to the Indian counterpart than to the Babylonian one. Sketching connections between Aryabhata's framework and earlier Indic astronomical ideas on yugas and cyclic calendar systems, it is argued that Aryabhata's system is an outgrowth of an earlier Indic tradition.

  12. Strategy as stretch and leverage.

    Science.gov (United States)

    Hamel, G; Prahalad, C K

    1993-01-01

    Global competition is not just product versus product or company versus company. It is mind-set versus mind-set. Driven to understand the dynamics of competition, we have learned a lot about what makes one company more successful than another. But to find the root of competitiveness--to understand why some companies create new forms of competitive advantage while others watch and follow--we must look at strategic mind-sets. For many managers, "being strategic" means pursuing opportunities that fit the company's resources. This approach is not wrong, Gary Hamel and C.K. Prahalad contend, but it obscures an approach in which "stretch" supplements fit and being strategic means creating a chasm between ambition and resources. Toyota, CNN, British Airways, Sony, and others all displaced competitors with stronger reputations and deeper pockets. Their secret? In each case, the winner had greater ambition than its well-endowed rivals. Winners also find less resource-intensive ways of achieving their ambitious goals. This is where leverage complements the strategic allocation of resources. Managers at competitive companies can get a bigger bang for their buck in five basic ways: by concentrating resources around strategic goals; by accumulating resources more efficiently; by complementing one kind of resource with another; by conserving resources whenever they can; and by recovering resources from the market-place as quickly as possible. As recent competitive battles have demonstrated, abundant resources can't guarantee continued industry leadership.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Investigation on thermomechanical properties of poly (l-lactic acid) for the stretch blow moulding process of bioresorbable vascular scaffold

    Science.gov (United States)

    Wei, Huidong; Menary, Gary

    2017-10-01

    Stretch blow moulding process has been used for the manufacture of bioresorbable vascular scaffold (BVS) made by poly (l-lactic acid) (PLLA) to improve its mechanical performance. In order to better understand the process, thermomechanical properties of PLLA were investigated by experimental method. Extruded PLLA sheets were biaxial stretched under strain rate of 1s-1, 4s-1 and 16s-1 to simulate the deformation process applicable in the blow moulding process. Both the equal-biaxial stretch and constant-width stretch were conducted by an in-house developed equipment. By differential scanning calorimeter (DSC), thermal analysis for materials before and after stretch were compared to evaluate the microstructural change of PLLA materials in the deformation process. A constitutive model based on glass rubber model was presented to simulate the mechanical behaviour of PLLA above glass transition under biaxial deformation.

  14. Effects of quadriceps and hamstrings proprioceptive neuromuscular facilitation stretching on knee movement sensation.

    Science.gov (United States)

    Streepey, Jefferson W; Mock, Marla J; Riskowski, Jody L; Vanwye, William R; Vitvitskiy, Boris M; Mikesky, Alan E

    2010-04-01

    Stretching before competition has traditionally been thought to benefit performance; however, recent evidence demonstrating reduced muscle force and power immediately after stretching suggests otherwise. We hypothesized that knee joint position sense would be diminished immediately after proprioceptive neuromuscular facilitation (PNF) stretching to the hamstrings and quadriceps. Eighteen subjects (aged 18-30 years) were seated with their dominant foot attached to a motorized arm with the knee flexed at 135 degrees . To block external cues, the subjects wore a blindfold, earplugs, and headphones providing white noise. The knee was displaced in either the flexion or the extension direction at a velocity of 0.4 degrees .s, and subjects pressed a button when they sensed motion. The knee was returned to 135 degrees , and the test was repeated for a total of 10 trials. The PNF group received PNF stretching to the hamstrings and quadriceps of the dominant leg. The SHAM group had the dominant leg passively moved within each subject's functional range of motion. The ability to detect knee movement was retested in the PNF and SHAM groups. Pre- and posttest latencies between movement onset and subject response were analyzed. Results indicated that the PNF group had significantly increased latencies after stretching (from 2.56 +/- 0.83 to 3.46 +/- 1.90 seconds) compared with the SHAM group (3.93 +/- 2.40 to 3.72 +/- 2.15 seconds). It is concluded that PNF stretching of the hamstrings and quadriceps may acutely diminish sensitivity to knee movement. For coaches and trainers, these findings are consistent with previous reports of loss in muscle force and power immediately after stretching, suggesting that stretching just before competition may diminish performance.

  15. A Novel Stretch Sensor to Measure Venous Hemodynamics

    Directory of Open Access Journals (Sweden)

    Syrpailyne Wankhar

    2018-07-01

    Full Text Available Chronic venous insufficiency is a debilitating condition causing varicose veins and venous ulcers. The pathophysiology includes reflux and venous obstruction. The diagnosis is often made by clinical examination and confirmed by Venous Doppler studies. Plethysmography helps to quantitatively examine the reflux and diagnose the burden of deep venous pathology to better understand venous hemodynamics, which is not elicited by venous duplex examination alone. However, most of these tests are qualitative, expensive, and not easily available. In this paper, we demonstrate the potential use of a novel stretch sensor in the assessment of venous hemodynamics during different maneuvers by measuring the change in calf circumference. We designed the stretch sensor by using semiconductor strain gauges pasted onto a small metal bar to form a load cell. The elastic and Velcro material attached to the load cell form a belt. It converts the change in limb circumference to a proportional tension (force of distension when placed around the calf muscle. We recorded the change in limb circumference from arrays of stretch sensors by using an in-house data acquisition system. We calculated the venous volume (VV, venous filling index (VFI, ejection fraction (EF and residual venous volume (RVV on two normal subjects and on two patients to assess venous hemodynamics. The values (VV > 60 ml, VFI 60%, RVV 2ml/s, EF 35% in patients were comparable to those reported in the literature.

  16. Acute Effect of Different Combined Stretching Methods on Acceleration and Speed in Soccer Players

    Directory of Open Access Journals (Sweden)

    Amiri-Khorasani Mohammadtaghi

    2016-04-01

    Full Text Available The purpose of this study was to investigate the acute effect of different stretching methods, during a warm-up, on the acceleration and speed of soccer players. The acceleration performance of 20 collegiate soccer players (body height: 177.25 ± 5.31 cm; body mass: 65.10 ± 5.62 kg; age: 16.85 ± 0.87 years; BMI: 20.70 ± 5.54; experience: 8.46 ± 1.49 years was evaluated after different warm-up procedures, using 10 and 20 m tests. Subjects performed five types of a warm-up: static, dynamic, combined static + dynamic, combined dynamic + static, and no-stretching. Subjects were divided into five groups. Each group performed five different warm-up protocols in five non-consecutive days. The warm-up protocol used for each group was randomly assigned. The protocols consisted of 4 min jogging, a 1 min stretching program (except for the no-stretching protocol, and 2 min rest periods, followed by the 10 and 20 m sprint test, on the same day. The current findings showed significant differences in the 10 and 20 m tests after dynamic stretching compared with static, combined, and no-stretching protocols. There were also significant differences between the combined stretching compared with static and no-stretching protocols. We concluded that soccer players performed better with respect to acceleration and speed, after dynamic and combined stretching, as they were able to produce more force for a faster execution.

  17. Can chronic stretching change the muscle-tendon mechanical properties? A review.

    Science.gov (United States)

    Freitas, S R; Mendes, B; Le Sant, G; Andrade, R J; Nordez, A; Milanovic, Z

    2018-03-01

    It is recognized that stretching is an effective method to chronically increase the joint range of motion. However, the effects of stretching training on the muscle-tendon structural properties remain unclear. This systematic review with meta-analysis aimed to determine whether chronic stretching alter the muscle-tendon structural properties. Published papers regarding longitudinal stretching (static, dynamic and/or PNF) intervention (either randomized or not) in humans of any age and health status, with more than 2 weeks in duration and at least 2 sessions per week, were searched in PubMed, PEDro, ScienceDirect and ResearchGate databases. Structural or mechanical variables from joint (maximal tolerated passive torque or resistance to stretch) or muscle-tendon unit (muscle architecture, stiffness, extensibility, shear modulus, volume, thickness, cross-sectional area, and slack length) were extracted from those papers. A total of 26 studies were selected, with a duration ranging from 3 to 8 weeks, and an average total time under stretching of 1165 seconds per week. Small effects were seen for maximal tolerated passive torque, but trivial effects were seen for joint resistance to stretch, muscle architecture, muscle stiffness, and tendon stiffness. A large heterogeneity was seen for most of the variables. Stretching interventions with 3- to 8-week duration do not seem to change either the muscle or the tendon properties, although it increases the extensibility and tolerance to a greater tensile force. Adaptations to chronic stretching protocols shorter than 8 weeks seem to mostly occur at a sensory level. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Changes of Reflex, Non-reflex and Torque Generation Properties of Spastic Ankle Plantar Flexors Induced by Intelligent Stretching.

    Science.gov (United States)

    Chung, S; Bai, Z; Rymer, W Z; Zhang, L Q

    2005-01-01

    Spasticity, contracture, and muscle weakness are major sources of disability in stroke. Changes of torque-generating capacity as well as reflex and non-reflex properties of ankle plantar flexors induced by strenuous stretching in chronic hemiplegia were investigated. Twelve subjects with a unilateral stroke and 10 healthy controls underwent 30 minutes of strenuous intelligent stretching treatment. Reflex and non-reflex components of spastic hypertonia and force-generating capacity of ankle plantar flexors were investigated. Dorsiflexion (DF) range of motion (ROM) was increased (p=0.002) and passive stiffness and passive resistant torque of the spastic muscles were decreased (p=0.004 and 0.007, respectively), while reflex hyper-excitability diminished slightly but with no statistical significance. The maximal voluntary contraction (MVC) torque of the spastic ankle plantar flexors was increased after the forceful stretching treatment (p=0.041). In contrast, the stretching treatment of the healthy plantar flexors did not change any of the variables measured before and after stretching. The stroke subjects who gained more DF ROM or larger decrement of stiffness achieved greater increment of the peak torque generation after the stretching (r=0.597 with p=0.040 and r=-0.746 with p=0.005, respectively). These results suggest that the strenuous dynamic stretching could improve the force-generating capacity of spastic muscles as well as reduce the passive stiffness and increase ROM.

  19. Stretch due to Penile Prosthesis Reservoir Migration

    Directory of Open Access Journals (Sweden)

    E. Baten

    2016-03-01

    Full Text Available A 43-year old patient presented to the emergency department with stretch, due to impossible deflation of the penile prosthesis, 4 years after successful implant. A CT-scan showed migration of the reservoir to the left rectus abdominis muscle. Refilling of the reservoir was inhibited by muscular compression, causing stretch. Removal and replacement of the reservoir was performed, after which the prosthesis was well-functioning again. Migration of the penile prosthesis reservoir is extremely rare but can cause several complications, such as stretch.

  20. Effect of modified hold-relax stretching and static stretching on hamstring muscle flexibility.

    Science.gov (United States)

    Ahmed, Hashim; Iqbal, Amir; Anwer, Shahnawaz; Alghadir, Ahmad

    2015-02-01

    [Purpose] The aim of present study was to compare the effectiveness of modified hold-relax stretching and static stretching in improving the hamstring muscle flexibility. [Subjects and Methods] Forty-five male subjects with hamstring tightness were included in this study. The subjects were randomly placed into three groups: the modified hold-relax stretching, static stretching and control groups. The modified hold-relax stretching group performed 7 seconds of isometric contraction and then relaxed for 5 seconds, and this was repeated five times daily for five consecutive days. The static stretching group received 10 minutes of static stretching with the help of a pulley and weight system for five consecutive days. The control group received only moist heat for 20 minutes for five consecutive days. A baseline reading of passive knee extension (PKE) was taken prior to the intervention; rest measurements were taken immediate post intervention on day 1, day 3, day 5, and after a 1 week follow-up, i.e., at the 12th day. [Results] On comparing the baseline readings of passive knee extension (PKE), there was no difference noted between the three groups. On comparing the posttest readings on day 5 between the 3 groups, a significant difference was noted. However, post hoc analysis revealed an insignificant difference between the modified hold-relax stretching and static stretching groups. There was a significant difference between the static stretching and control groups and between the modified hold-relax stretching and control groups. [Conclusion] The results of this study indicate that both the modified hold-relax stretching technique and static stretching are equally effective, as there was no significant difference in improving the hamstring muscle flexibility between the two groups.

  1. Cyclic stretch induces cell reorientation on substrates by destabilizing catch bonds in focal adhesions.

    Directory of Open Access Journals (Sweden)

    Bin Chen

    Full Text Available A minimal model of cellular mechanosensing system that consists of a single stress fiber adhering on a substrate via two focal adhesions made of catch bonds is adopted to investigate the phenomena of cell reorientation on substrates induced by an applied uniaxial cyclic stretch. The model indicates that the catch bonds in the focal adhesions experience a periodically oscillating internal force with amplitude and frequency controlled by two intrinsic clocks of the stress fiber, one associated with localized activation and the other with homogeneous activation of sarcomere units along the stress fiber. It is shown that this oscillating force due to cyclic stretch tends to destabilize focal adhesions by reducing the lifetime of catch bonds. The resulting slide or relocation of focal adhesions then causes the associated stress fiber to shorten and rotate to configurations nearly perpendicular to the stretching direction. These predicted behaviors from our model are consistent with a wide range of experimental observations.

  2. The cosmological constant problem

    International Nuclear Information System (INIS)

    Dolgov, A.D.

    1989-05-01

    A review of the cosmological term problem is presented. Baby universe model and the compensating field model are discussed. The importance of more accurate data on the Hubble constant and the Universe age is stressed. 18 refs

  3. Deconstructing the Cosmological Constant

    CERN Document Server

    Jejjala, V; Minic, D; Jejjala, Vishnu; Leigh, Robert G.; Minic, Djordje

    2003-01-01

    Deconstruction provides a novel way of dealing with the notoriously difficult ultraviolet problems of four-dimensional gravity. This approach also naturally leads to a new perspective on the holographic principle, tying it to the fundamental requirements of unitarity and diffeomorphism invariance, as well as to a new viewpoint on the cosmological constant problem. The numerical smallness of the cosmological constant is implied by a unique combination of holography and supersymmetry, opening a new window into the fundamental physics of the vacuum.

  4. Investing in a Large Stretch Press

    Science.gov (United States)

    Choate, M.; Nealson, W.; Jay, G.; Buss, W.

    1986-01-01

    Press for forming large aluminum parts from plates provides substantial economies. Study assessed advantages and disadvantages of investing in large stretch-forming press, and also developed procurement specification for press.

  5. Tip opening of premixed bunsen flames: Extinction with negative stretch and local Karlovitz number

    KAUST Repository

    Vu, Tranmanh

    2015-04-01

    The characteristics of tip openings in premixed bunsen flames have been studied experimentally by measuring OH radicals from laser-induced fluorescence and tip curvatures from chemiluminescent images. Results showed that the tip opening occurred at a constant equivalence ratio and was independent of the jet velocity in propane/air mixtures. The observation of a local extinction phenomenon of the negatively stretched flame due to the flame curvature could not be consistently explained based on flame stretch or the Karlovitz number, since they varied appreciably with the jet velocity. The concept of the local Karlovitz number (KaL) was introduced, which is defined as the ratio of the characteristic reaction time in the normal direction for a stretched flame to the characteristic flow time in the tangential direction for the stretched flame. The local Karlovitz number maintained a constant value under tip opening conditions, irrespective of the jet velocity. Tip opening occurred at a reasonably constant local Karlovitz number of about ~1.72 when the nitrogen dilution level in propane and n-butane fuels was varied.

  6. Stability constants of the Europium complexes with the chloride ions

    International Nuclear Information System (INIS)

    Jimenez R, M.; Solache R, M.; Rojas H, A.

    2000-01-01

    The stability constants of lanthanides complexes with chloride ions which were determined at the same ionic force but in different media, are significantly different. It does not exist a systematic study over these stability constants. The purpose of this work is to determine the stability constants of the europium complexes with chloride ions at 303 K, by the solvents extraction method. (Author)

  7. Comparison of two stretching methods and optimization of stretching protocol for the piriformis muscle.

    Science.gov (United States)

    Gulledge, Brett M; Marcellin-Little, Denis J; Levine, David; Tillman, Larry; Harrysson, Ola L A; Osborne, Jason A; Baxter, Blaise

    2014-02-01

    Piriformis syndrome is an uncommon diagnosis for a non-discogenic form of sciatica whose treatment has traditionally focused on stretching the piriformis muscle (PiM). Conventional stretches include hip flexion, adduction, and external rotation. Using three-dimensional modeling, we quantified the amount of (PiM) elongation resulting from two conventional stretches and we investigated by use of a computational model alternate stretching protocols that would optimize PiM stretching. Seven subjects underwent three CT scans: one supine, one with hip flexion, adduction, then external rotation (ADD stretch), and one with hip flexion, external rotation, then adduction (ExR stretch). Three-dimensional bone models were constructed from the CT scans. PiM elongation during these stretches, femoral neck inclination, femoral head anteversion, and trochanteric anteversion were measured. A computer program was developed to map PiM length over a range of hip joint positions and was validated against the measured scans. ExR and ADD stretches elongated the PiM similarly by approximately 12%. Femoral head and greater trochanter anteversion influenced PiM elongation. Placing the hip joints in 115° of hip flexion, 40° of external rotation and 25° of adduction or 120° of hip flexion, 50° of external rotation and 30° of adduction increased PiM elongation by 30-40% compared to conventional stretches (15.1 and 15.3% increases in PiM muscle length, respectively). ExR and ADD stretches elongate the PiM similarly and therefore may have similar clinical effectiveness. The optimized stretches led to larger increases in PiM length and may be more easily performed by some patients due to increased hip flexion. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Effects of proprioceptive neuromuscular facilitation stretching and static stretching on maximal voluntary contraction.

    Science.gov (United States)

    Miyahara, Yutetsu; Naito, Hisashi; Ogura, Yuji; Katamoto, Shizuo; Aoki, Junichiro

    2013-01-01

    This study was undertaken to investigate and compare the effects of proprioceptive neuromuscular facilitation (PNF) stretching and static stretching on maximal voluntary contraction (MVC). Thirteen male university students (age, 20 ± 1 years; height, 172.2 ± 4.6 cm; weight, 68.4 ± 6.7 kg; mean ± SD) completed 3 different conditions on 3 nonconsecutive days in randomized order: static stretching (SS), PNF stretching (PNF), and no stretching (control, CON). Each condition consisted of a 5-minute rest accompanied by one of the following activities: (a) control, (b) SS, or (c) PNF stretching. The hip flexion range of motion (ROM) was evaluated immediately before and after the activity. The MVC of knee flexion was then measured. Surface electromyography was recorded from the biceps femoris and vastus lateralis muscles during MVC tests and stretching. Although increases in ROM were significantly greater after PNF than after SS (p < 0.01), the decreases in MVC were similar between the 2 treatments. These results suggest that, although PNF stretching increases ROM more than SS, PNF stretching and SS is detrimental to isometric maximal strength.

  9. Stretch-induced intussuceptive and sprouting angiogenesis in the chick chorioallantoic membrane.

    Science.gov (United States)

    Belle, Janeil; Ysasi, Alexandra; Bennett, Robert D; Filipovic, Nenad; Nejad, Mohammad Imani; Trumper, David L; Ackermann, Maximilian; Wagner, Willi; Tsuda, Akira; Konerding, Moritz A; Mentzer, Steven J

    2014-09-01

    Vascular systems grow and remodel in response to not only metabolic needs, but also mechanical influences as well. Here, we investigated the influence of tissue-level mechanical forces on the patterning and structure of the chick chorioallantoic membrane (CAM) microcirculation. A dipole stretch field was applied to the CAM using custom computer-controlled servomotors. The topography of the stretch field was mapped using finite element models. After 3days of stretch, Sholl analysis of the CAM demonstrated a 7-fold increase in conducting vessel intersections within the stretch field (p0.05). In contrast, corrosion casting and SEM of the stretch field capillary meshwork demonstrated intense sprouting and intussusceptive angiogenesis. Both planar surface area (p<0.05) and pillar density (p<0.01) were significantly increased relative to control regions of the CAM. We conclude that a uniaxial stretch field stimulates the axial growth and realignment of conducting vessels as well as intussusceptive and sprouting angiogenesis within the gas exchange capillaries of the ex ovo CAM. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Stretch-induced Intussuceptive and Sprouting Angiogenesis in the Chick Chorioallantoic Membrane

    Science.gov (United States)

    Belle, Janeil; Ysasi, Alexandra; Bennett, Robert; Filipovic, Nenad; Nejad, Mohammad Imani; Trumper, David L.; Ackermann, Max; Wagner, Willi; Tsuda, Akira; Konerding, Moritz A.; Mentzer, Steven J.

    2014-01-01

    Vascular systems grow and remodel in response to not only metabolic needs, but mechanical influences as well. Here, we investigated the influence of tissue-level mechanical forces on the patterning and structure of the chick chorioallantoic membrane (CAM) microcirculation. A dipole stretch field was applied to the CAM using custom computer-controlled servomotors. The topography of the stretch field was mapped using finite element models. After 3 days of stretch, Sholl analysis of the CAM demonstrated a 7-fold increase in conducting vessel intersections within the stretch field (p0.05). In contrast, corrosion casting and SEM of the stretch field capillary meshwork demonstrated intense sprouting and intussusceptive angiogenesis. Both planar surface area (p<0.05) and pillar density (p<0.01) were significantly increased relative to control regions of the CAM. We conclude that a uniaxial stretch field stimulates the axial growth and realignment of conducting vessels as well as intussusceptive and sprouting angiogenesis within the gas exchange capillaries of the ex ovo CAM. PMID:24984292

  11. MHD biconvective flow of Powell Eyring nanofluid over stretched surface

    Science.gov (United States)

    Naseem, Faiza; Shafiq, Anum; Zhao, Lifeng; Naseem, Anum

    2017-06-01

    The present work is focused on behavioral characteristics of gyrotactic microorganisms to describe their role in heat and mass transfer in the presence of magnetohydrodynamic (MHD) forces in Powell-Eyring nanofluids. Implications concerning stretching sheet with respect to velocity, temperature, nanoparticle concentration and motile microorganism density were explored to highlight influential parameters. Aim of utilizing microorganisms was primarily to stabilize the nanoparticle suspension due to bioconvection generated by the combined effects of buoyancy forces and magnetic field. Influence of Newtonian heating was also analyzed by taking into account thermophoretic mechanism and Brownian motion effects to insinuate series solutions mediated by homotopy analysis method (HAM). Mathematical model captured the boundary layer regime that explicitly involved contemporary non linear partial differential equations converted into the ordinary differential equations. To depict nanofluid flow characteristics, pertinent parameters namely bioconvection Lewis number Lb, traditional Lewis number Le, bioconvection Péclet number Pe, buoyancy ratio parameter Nr, bioconvection Rayleigh number Rb, thermophoresis parameter Nt, Hartmann number M, Grashof number Gr, and Eckert number Ec were computed and analyzed. Results revealed evidence of hydromagnetic bioconvection for microorganism which was represented by graphs and tables. Our findings further show a significant effect of Newtonian heating over a stretching plate by examining the coefficient values of skin friction, local Nusselt number and the local density number. Comparison was made between Newtonian fluid and Powell-Eyring fluid on velocity field and temperature field. Results are compared of with contemporary studies and our findings are found in excellent agreement with these studies.

  12. Determination of the constants of the solubility product of Ln(OH)3 and the effect of the chloride ions on the lanthanum hydrolysis, praseodymium and lutetium in aqueous solutions of ion force 2 Molar

    International Nuclear Information System (INIS)

    Lopez G, H.D.

    2005-01-01

    The behavior of lanthanum (III), praseodymium (III), and lutetium (III) was studied in 2 M NaClO 4 (aq) and 2 M NaCl (aq) at 303 K and free -CO 2 conditions. Solubility diagrams (p Ln(aq)-pC H ) were obtained by means of a radiochemical method. The pC H borderlines of saturation and unsaturation zones of the solutions and solubility product constants for Ln(OH) 3 were determined from these diagrams. The fitting of the solubility equation to the experimental values of p Ln(aq)-pC H diagrams allowed the calculation of the first hydrolysis and solubility product constants. Independently, the stability constants for the first species of hydrolysis were determined by means of pH titrations, the data were treated with the program SUPERQUAD and fitted to the mean ligand number equation. The stability constants for the species LnCl 2+ were as well calculated in 2M ionic strength and 303 K from the hydrolysis constant values obtained in both perchlorate and chloride media. The values obtained for La, Pr and Lu were: logK ps : 21.11 ± 0.09, 19.81 ± 0.11 and 18.10 ± 0.13 in 2M NaClO 4 ; logK ps : 22.22 ± 0.09, 21.45 ± 0.14 and 18.52 ± 0.29 in 2M NaCl; log β 1 : - 8.64 ± 0.02, - 8.37 ± 0.01 and - 7.95 ± 0.11 in 2M NaClO 4 ; log β 1 / : - 9.02 ± 0.11, - 8.75 ± 0.01 and - 8.12 ± 0.03 in 2M NaCl and the values for log β 1,Cl were - 0.0255, - 0.155 and - 0.758, respectively. (Author)

  13. Elastic constants of calcite

    Science.gov (United States)

    Peselnick, L.; Robie, R.A.

    1962-01-01

    The recent measurements of the elastic constants of calcite by Reddy and Subrahmanyam (1960) disagree with the values obtained independently by Voigt (1910) and Bhimasenachar (1945). The present authors, using an ultrasonic pulse technique at 3 Mc and 25??C, determined the elastic constants of calcite using the exact equations governing the wave velocities in the single crystal. The results are C11=13.7, C33=8.11, C44=3.50, C12=4.82, C13=5.68, and C14=-2.00, in units of 1011 dyncm2. Independent checks of several of the elastic constants were made employing other directions and polarizations of the wave velocities. With the exception of C13, these values substantially agree with the data of Voigt and Bhimasenachar. ?? 1962 The American Institute of Physics.

  14. Fundamental physics constants

    International Nuclear Information System (INIS)

    Cohen, E.R.; Taylor, B.N.

    1995-01-01

    Present technological applications require the values used for the fundamental physical and chemical constants to be more and more precise and at the same time coherent. Great importance is then attached to the task of coordinating and comparing the most recent experimental data, extracting from them as a whole, by means of a least square fit, a set of values for the fundamental constants as precise and coherent as possible. The set of values which is at present in usage, derives from a fit performed in 1986, but new experimental results already promise a large reduction in the uncertainties of various constants. A new global fit that will implement such reductions is scheduled for completion in 1995 or 1996

  15. Outcome of Specific Piriformis Stretching Technique in Females with Piriformis Syndrome

    Directory of Open Access Journals (Sweden)

    Quratulain Saeed

    2017-10-01

    Full Text Available BACKGROUND: Pain and functional limitation affect the quality of life in piriformis syndrome. Stretching of piriformis is essential in the treatment protocols in physiotherapy, however, which sequence of stretching provides optimal improvement is only determined by trial and error. The purpose of this study was to compare the effects of specific stretching technique in terms of functional outcome in female with piriformis syndrome and to determine the normative length of piriformis at different reference points in females. METHODS: This study was a randomized controlled trial that was conducted in the Physiotherapy Department of the Armed Forces Institute of Rehabilitation Medicine, Rawalpindi, Pakistan between July to December, 2015. This study enrolled 30 patients with piriformis syndrome at outpatient department between the ages of 20 and 50 years. These patients were randomly assigned into two groups. In one group, external rotator sequence of self-stretching (ERS was practiced while in the second group, adductor sequence of passive stretching (APS was performed. Each group was treated for two weeks. Pre and post intervention, the assessment was made on Numerical Pain Rating Scale (NPRS, Functional Performance of Lower Extremity Scale (FPLES and by measured length at three reference positions. Independent T-test was used for statistical analysis. RESULTS: Both groups showed improvement in outcome in term of a decrease in pain score on NRPS, FPLES and measured reference lengths at all three positions (p-value 0.05 when results of pain score and measured reference length at three different positions were compared. However, on the FPLES, external rotator stretching technique was more effective than adductor stretching technique (p value < 0.05. CONCLUSION: The two studied sequence of piriformis stretching exercises have the same effect on outcomes in terms of clinically measured referenced length and decrease in pain score. Future studies will

  16. Radiographic constant exposure technique

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1985-01-01

    The constant exposure technique has been applied to assess various industrial radiographic systems. Different X-ray films and radiographic papers of two producers were compared. Special attention was given to fast film and paper used with fluorometallic screens. Radiographic image quality was tes...... was tested by the use of ISO wire IQI's and ASTM penetrameters used on Al and Fe test plates. Relative speed and reduction of kilovoltage obtained with the constant exposure technique were calculated. The advantages of fast radiographic systems are pointed out...

  17. Radiographic constant exposure technique

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1985-01-01

    The constant exposure technique has been applied to assess various industrial radiographic systems. Different X-ray films and radiographic papers of two producers were compared. Special attention was given to fast film and paper used with fluorometallic screens. Radiographic image quality...... was tested by the use of ISO wire IQI's and ASTM penetrameters used on Al and Fe test plates. Relative speed and reduction of kilovoltage obtained with the constant exposure technique were calculated. The advantages of fast radiographic systems are pointed out...

  18. Comparison of active stretching technique and static stretching technique on hamstring flexibility.

    Science.gov (United States)

    Meroni, Roberto; Cerri, Cesare Giuseppe; Lanzarini, Carlo; Barindelli, Guido; Morte, Giancesare Della; Gessaga, Viviana; Cesana, Gian Carlo; De Vito, Giovanni

    2010-01-01

    To compare a passive and an active stretching technique to determine which one would produce and maintain the greatest gain in hamstring flexibility. To determine whether a passive or an active stretching technique results in a greater increase in hamstring flexibility and to compare whether the gains are maintained. Randomized controlled trial. Institutional. Sixty-five volunteer healthy subjects completed the enrollment questionnaire, 33 completed the required 75% of the treatment after 6 weeks, and 22 were assessed 4 weeks after the training interruption. A 6-week stretching program with subjects divided into 2 groups with group 1 performing active stretching exercises and group 2 performing passive stretching exercises. Range of motion (ROM) was measured after 3 and 6 weeks of training and again 4 weeks after the cessation of training and compared with the initial measurement. After 3 weeks of training, the mean gain in group 1 (active stretching) on performing the active knee extension range of motion (AKER) test was 5.7 degrees, whereas the mean gain in group 2 (passive stretching) was 3 degrees (P = .015). After 6 weeks of training, the mean gain in group 1 was 8.7 degrees , whereas the mean gain in group 2 was 5.3 degrees (P = .006). Twenty-two subjects were reassessed 4 weeks after the cessation of the training with the maintained gain of ROM in group 1 being 6.3 degrees , whereas the maintained gain in group 2 was 0.1 degrees (P = .003). Active stretching produced the greater gain in the AKER test, and the gain was almost completely maintained 4 weeks after the end of the training, which was not seen with the passive stretching group. Active stretching was more time efficient compared with the static stretching and needed a lower compliance to produce effects on flexibility.

  19. Redundant internal coordinates, compliance constants and non ...

    Indian Academy of Sciences (India)

    Abstract. A long standing problem in normal mode analysis is identifying the right internal coordinates given only the cartesian coordinates, the masses of the atoms and the cartesian force constants without using any other additional chemical information. A possible solution is suggested here as drawing the normal modes.

  20. Convective Heat Transfer Scaling of Ignition Delay and Burning Rate with Heat Flux and Stretch Rate in the Equivalent Low Stretch Apparatus

    Science.gov (United States)

    Olson, Sandra

    2011-01-01

    To better evaluate the buoyant contributions to the convective cooling (or heating) inherent in normal-gravity material flammability test methods, we derive a convective heat transfer correlation that can be used to account for the forced convective stretch effects on the net radiant heat flux for both ignition delay time and burning rate. The Equivalent Low Stretch Apparatus (ELSA) uses an inverted cone heater to minimize buoyant effects while at the same time providing a forced stagnation flow on the sample, which ignites and burns as a ceiling fire. Ignition delay and burning rate data is correlated with incident heat flux and convective heat transfer and compared to results from other test methods and fuel geometries using similarity to determine the equivalent stretch rates and thus convective cooling (or heating) rates for those geometries. With this correlation methodology, buoyant effects inherent in normal gravity material flammability test methods can be estimated, to better apply the test results to low stretch environments relevant to spacecraft material selection.

  1. Infrared spectra of CF(2)=CHD and CF(2)=CD(2): scaled quantum-chemical force fields and an equilibrium structure for 1,1-difluoroethylene.

    Science.gov (United States)

    McKean, Donald C; Law, Mark M; Groner, Peter; Conrad, Andrew R; Tubergen, Michael J; Feller, David; Moore, Michael C; Craig, Norman C

    2010-09-02

    Infrared (IR) spectra in the gas phase are reported for CF(2)=CHD and CF(2)=CD(2) in the region 350-4000 cm(-1). Ab initio calculations of an harmonic force-field and anharmonicity constants have been made with an MP2/aug-cc-pVTZ model. These enable a number of Fermi resonances in each species to be analyzed and a complete set of "observed" harmonic frequencies to be derived. The latter are combined with similar data for CF(2)=CH(2) in a scaling of the model harmonic force field to both anharmonic and harmonic frequencies. Inspection of the scale factors reveals minor defects of the model, evident in the out-of-plane wagging modes and in the CF stretch/CF stretch interaction force constant. Fermi resonance treatments involved in all isotopomers studied are compatible with the overall force-field refinement results. The treatment leaves a small anomaly in the (13)C shift on nu(1). Improved microwave spectra are reported for five isotopic species, and a semiexperimental equilibrium structure for F(2)C=CH(2) is determined and compared favorably with the structure obtained from new high-level ab initio calculations. Centrifugal distortion constants are predicted for the five isotopic species, and those for F(2)C=CH(2) are compared with values fit to microwave spectra.

  2. Fast optimization algorithms and the cosmological constant

    Science.gov (United States)

    Bao, Ning; Bousso, Raphael; Jordan, Stephen; Lackey, Brad

    2017-11-01

    Denef and Douglas have observed that in certain landscape models the problem of finding small values of the cosmological constant is a large instance of a problem that is hard for the complexity class NP (Nondeterministic Polynomial-time). The number of elementary operations (quantum gates) needed to solve this problem by brute force search exceeds the estimated computational capacity of the observable Universe. Here we describe a way out of this puzzling circumstance: despite being NP-hard, the problem of finding a small cosmological constant can be attacked by more sophisticated algorithms whose performance vastly exceeds brute force search. In fact, in some parameter regimes the average-case complexity is polynomial. We demonstrate this by explicitly finding a cosmological constant of order 10-120 in a randomly generated 1 09-dimensional Arkani-Hamed-Dimopoulos-Kachru landscape.

  3. The Yamabe constant

    International Nuclear Information System (INIS)

    O Murchadha, N.

    1991-01-01

    The set of riemannian three-metrics with positive Yamabe constant defines the space of independent data for the gravitational field. The boundary of this set is investigated, and it is shown that metrics close to the boundary satisfy the positive-energy theorem. (Author) 18 refs

  4. FORMATION CONSTANTS AND THERMODYNAMIC ...

    African Journals Online (AJOL)

    , Ni(II), Cu(II) and Zn(II) ions has been ... A good deal of work has been reported on the preparation and structural investigation of. Schiff base ... Formation constants and thermodynamic parameters of Co, Ni, Cu and Zn complexes. Bull. Chem.

  5. How to determine local stretching and tension in a flow-stretched DNA molecule

    DEFF Research Database (Denmark)

    Pedersen, Jonas Nyvold; Marie, Rodolphe; Kristensen, Anders

    2016-01-01

    We determine the nonuniform stretching of and tension in amega base pairs-long fragment of deoxyribonucleic acid (DNA) that is flow stretched in a nanofluidic chip. We use no markers, do not know the contour length of the DNA, and do not have the full DNA molecule inside our field of view. Instead...

  6. CURRENT CONCEPTS IN MUSCLE STRETCHING FOR EXERCISE AND REHABILITATION

    Science.gov (United States)

    2012-01-01

    Stretching is a common activity used by athletes, older adults, rehabilitation patients, and anyone participating in a fitness program. While the benefits of stretching are known, controversy remains about the best type of stretching for a particular goal or outcome. The purpose of this clinical commentary is to discuss the current concepts of muscle stretching interventions and summarize the evidence related to stretching as used in both exercise and rehabilitation. PMID:22319684

  7. CURRENT CONCEPTS IN MUSCLE STRETCHING FOR EXERCISE AND REHABILITATION

    OpenAIRE

    Page, Phil

    2012-01-01

    Stretching is a common activity used by athletes, older adults, rehabilitation patients, and anyone participating in a fitness program. While the benefits of stretching are known, controversy remains about the best type of stretching for a particular goal or outcome. The purpose of this clinical commentary is to discuss the current concepts of muscle stretching interventions and summarize the evidence related to stretching as used in both exercise and rehabilitation.

  8. Optofluidic time-stretch microscopy: recent advances

    Science.gov (United States)

    Lei, Cheng; Nitta, Nao; Ozeki, Yasuyuki; Goda, Keisuke

    2018-04-01

    Flow cytometry is an indispensable method for valuable applications in numerous fields such as immunology, pathology, pharmacology, molecular biology, and marine biology. Optofluidic time-stretch microscopy is superior to conventional flow cytometry methods for its capability to acquire high-quality images of single cells at a high-throughput exceeding 10,000 cells per second. This makes it possible to extract copious information from cellular images for accurate cell detection and analysis with the assistance of machine learning. Optofluidic time-stretch microscopy has proven its effectivity in various applications, including microalga-based biofuel production, evaluation of thrombotic disorders, as well as drug screening and discovery. In this review, we discuss the principles and recent advances of optofluidic time-stretch microscopy.

  9. Optofluidic time-stretch quantitative phase microscopy.

    Science.gov (United States)

    Guo, Baoshan; Lei, Cheng; Wu, Yi; Kobayashi, Hirofumi; Ito, Takuro; Yalikun, Yaxiaer; Lee, Sangwook; Isozaki, Akihiro; Li, Ming; Jiang, Yiyue; Yasumoto, Atsushi; Di Carlo, Dino; Tanaka, Yo; Yatomi, Yutaka; Ozeki, Yasuyuki; Goda, Keisuke

    2018-03-01

    Innovations in optical microscopy have opened new windows onto scientific research, industrial quality control, and medical practice over the last few decades. One of such innovations is optofluidic time-stretch quantitative phase microscopy - an emerging method for high-throughput quantitative phase imaging that builds on the interference between temporally stretched signal and reference pulses by using dispersive properties of light in both spatial and temporal domains in an interferometric configuration on a microfluidic platform. It achieves the continuous acquisition of both intensity and phase images with a high throughput of more than 10,000 particles or cells per second by overcoming speed limitations that exist in conventional quantitative phase imaging methods. Applications enabled by such capabilities are versatile and include characterization of cancer cells and microalgal cultures. In this paper, we review the principles and applications of optofluidic time-stretch quantitative phase microscopy and discuss its future perspective. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Bias of purine stretches in sequenced chromosomes

    DEFF Research Database (Denmark)

    Ussery, David; Soumpasis, Dikeos Mario; Brunak, Søren

    2002-01-01

    We examined more than 700 DNA sequences (full length chromosomes and plasmids) for stretches of purines (R) or pyrimidines (Y) and alternating YR stretches; such regions will likely adopt structures which are different from the canonical B-form. Since one turn of the DNA helix is roughly 10 bp, we...... measured the fraction of each genome which contains purine (or pyrimidine) tracts of lengths of 10 by or longer (hereafter referred to as 'purine tracts'), as well as stretches of alternating pyrimidines/purine ('pyr/pur tracts') of the same length. Using this criteria, a random sequence would be expected...... to contain 1.0% of purine tracts and also 1.0% of the alternating pyr/pur tracts. In the vast majority of cases, there are more purine tracts than would be expected from a random sequence, with an average of 3.5%, significantly larger than the expectation value. The fraction of the chromosomes containing pyr...

  11. Bias of purine stretches in sequenced chromosomes

    DEFF Research Database (Denmark)

    Ussery, David; Soumpasis, Dikeos Mario; Brunak, Søren

    2002-01-01

    We examined more than 700 DNA sequences (full length chromosomes and plasmids) for stretches of purines (R) or pyrimidines (Y) and alternating YR stretches; such regions will likely adopt structures which are different from the canonical B-form. Since one turn of the DNA helix is roughly 10 bp, we...... to contain 1.0% of purine tracts and also 1.0% of the alternating pyr/pur tracts. In the vast majority of cases, there are more purine tracts than would be expected from a random sequence, with an average of 3.5%, significantly larger than the expectation value. The fraction of the chromosomes containing pyr......, in eukaryotes there is an abundance of long stretches of purines or alternating purine/pyrimidine tracts, which cannot be explained in this way; these sequences are likely to play an important role in eukaryotic chromosome organisation....

  12. Renormalization of Newton's constant

    Science.gov (United States)

    Falls, Kevin

    2015-12-01

    The problem of obtaining a gauge independent beta function for Newton's constant is addressed. By a specific parametrization of metric fluctuations a gauge independent functional integral is constructed for the semiclassical theory around an arbitrary Einstein space. The effective action then has the property that only physical polarizations of the graviton contribute, while all other modes cancel with the functional measure. We are then able to compute a gauge independent beta function for Newton's constant in d dimensions to one-loop order. No Landau pole is present provided Ng<18 , where Ng=d (d -3 )/2 is the number of polarizations of the graviton. While adding a large number of matter fields can change this picture, the absence of a pole persists for the particle content of the standard model in four spacetime dimensions.

  13. Production in constant evolution

    International Nuclear Information System (INIS)

    Lozano, T.

    2009-01-01

    The Cofrentes Nuclear Power Plant now has 25 years of operation behind it: a quarter century adding value and demonstrating the reasons why it is one of the most important energy producing facilities in the Spanish power market. Particularly noteworthy is the enterprising spirit of the plant, which has strived to continuously improve with the large number of modernization projects that it has undertaken over the past 25 years. The plant has constantly evolved thanks to the amount of investments made to improve safety and reliability and the perseverance to stay technologically up to date. Efficiency, training and teamwork have been key to the success of the plant over these 25 years of constant change and progress. (Author)

  14. The Fine Structure Constant

    Indian Academy of Sciences (India)

    IAS Admin

    important parameter in the field of atomic struc- ture. The values of the constants of ... tions in their core that produce carbon. As a result, .... atom in 1913. In other words, the size of a hydrogen atom is a factor α−2 ≈ 20000 times the size of an elec- tron. Another way of looking at α is to consider the ratio of the orbital speed of ...

  15. The cosmological constant

    International Nuclear Information System (INIS)

    Mellor, F.

    1989-01-01

    Astronomical observations predict to an extremely accurate degree that the cosmological term in Einstein's equations should be zero. This conflicts with the predictions from particle theories of a non-zero cosmological term. Attempts to resolve this paradox range from arguments based on the anthropic principle to supersymmetric theories to quantum cosmological proposals. These approaches are discussed here and the history of the cosmological constant is reviewed. (author)

  16. The Hubble Constant.

    Science.gov (United States)

    Jackson, Neal

    2015-01-01

    I review the current state of determinations of the Hubble constant, which gives the length scale of the Universe by relating the expansion velocity of objects to their distance. There are two broad categories of measurements. The first uses individual astrophysical objects which have some property that allows their intrinsic luminosity or size to be determined, or allows the determination of their distance by geometric means. The second category comprises the use of all-sky cosmic microwave background, or correlations between large samples of galaxies, to determine information about the geometry of the Universe and hence the Hubble constant, typically in a combination with other cosmological parameters. Many, but not all, object-based measurements give H 0 values of around 72-74 km s -1 Mpc -1 , with typical errors of 2-3 km s -1 Mpc -1 . This is in mild discrepancy with CMB-based measurements, in particular those from the Planck satellite, which give values of 67-68 km s -1 Mpc -1 and typical errors of 1-2 km s -1 Mpc -1 . The size of the remaining systematics indicate that accuracy rather than precision is the remaining problem in a good determination of the Hubble constant. Whether a discrepancy exists, and whether new physics is needed to resolve it, depends on details of the systematics of the object-based methods, and also on the assumptions about other cosmological parameters and which datasets are combined in the case of the all-sky methods.

  17. Universe of constant

    Science.gov (United States)

    Yongquan, Han

    2016-10-01

    The ideal gas state equation is not applicable to ordinary gas, it should be applied to the Electromagnetic ``gas'' that is applied to the radiation, the radiation should be the ultimate state of matter changes or initial state, the universe is filled with radiation. That is, the ideal gas equation of state is suitable for the Singular point and the universe. Maybe someone consider that, there is no vessel can accommodate radiation, it is because the Ordinary container is too small to accommodate, if the radius of your container is the distance that Light through an hour, would you still think it can't accommodates radiation? Modern scientific determinate that the radius of the universe now is about 1027 m, assuming that the universe is a sphere whose volume is approximately: V = 4.19 × 1081 cubic meters, the temperature radiation of the universe (cosmic microwave background radiation temperature of the universe, should be the closest the average temperature of the universe) T = 3.15k, radiation pressure P = 5 × 10-6 N / m 2, according to the law of ideal gas state equation, PV / T = constant = 6 × 1075, the value of this constant is the universe, The singular point should also equal to the constant Author: hanyongquan

  18. Flow of nanofluid by nonlinear stretching velocity

    Science.gov (United States)

    Hayat, Tasawar; Rashid, Madiha; Alsaedi, Ahmed; Ahmad, Bashir

    2018-03-01

    Main objective in this article is to model and analyze the nanofluid flow induced by curved surface with nonlinear stretching velocity. Nanofluid comprises water and silver. Governing problem is solved by using homotopy analysis method (HAM). Induced magnetic field for low magnetic Reynolds number is not entertained. Development of convergent series solutions for velocity and skin friction coefficient is successfully made. Pressure in the boundary layer flow by curved stretching surface cannot be ignored. It is found that magnitude of power-law index parameter increases for pressure distibutions. Magnitude of radius of curvature reduces for pressure field while opposite trend can be observed for velocity.

  19. Stretching and folding mechanism in foams

    Energy Technology Data Exchange (ETDEWEB)

    Tufaile, Alberto [Escola de Artes, Ciencias e Humanidades, Soft Matter Laboratory, Universidade de Sao Paulo, 03828-000 Sao Paulo, SP (Brazil)], E-mail: tufaile@usp.br; Pedrosa Biscaia Tufaile, Adriana [Escola de Artes, Ciencias e Humanidades, Soft Matter Laboratory, Universidade de Sao Paulo, 03828-000 Sao Paulo, SP (Brazil)

    2008-10-13

    We have described the stretching and folding of foams in a vertical Hele-Shaw cell containing air and a surfactant solution, from a sequence of upside-down flips. Besides the fractal dimension of the foam, we have observed the logistic growth for the soap film length. The stretching and folding mechanism is present during the foam formation, and this mechanism is observed even after the foam has reached its respective maximum fractal dimension. Observing the motion of bubbles inside the foam, large bubbles present power spectrum associated with random walk motion in both directions, while the small bubbles are scattered like balls in a Galton board.

  20. Stretch-shortening cycle muscle power in women and men aged 18-81 years

    DEFF Research Database (Denmark)

    Edwén, C E; Thorlund, Jonas Bloch; Magnusson, Stig Peter

    2014-01-01

    This study explored the age-related deterioration in stretch-shortening cycle (SSC) muscle power and concurrent force-velocity properties in women and men across the adult life span. A total of 315 participants (women: n = 188; men: n = 127) aged 18-81 years performed maximal countermovement jump...... on an instrumented force plate. Maximal SSC leg extension power expressed per kg body mass (Ppeak) was greater in men than in women across the adult age span (P ......This study explored the age-related deterioration in stretch-shortening cycle (SSC) muscle power and concurrent force-velocity properties in women and men across the adult life span. A total of 315 participants (women: n = 188; men: n = 127) aged 18-81 years performed maximal countermovement jumps...

  1. Mechanical stretch augments insulin-induced vascular smooth muscle cell proliferation by insulin-like growth factor-1 receptor

    International Nuclear Information System (INIS)

    Liu, Gang; Hitomi, Hirofumi; Hosomi, Naohisa; Lei, Bai; Nakano, Daisuke; Deguchi, Kazushi; Mori, Hirohito; Masaki, Tsutomu; Ma, Hong; Griendling, Kathy K.; Nishiyama, Akira

    2011-01-01

    Insulin resistance and hypertension have been implicated in the pathogenesis of cardiovascular disease; however, little is known about the roles of insulin and mechanical force in vascular smooth muscle cell (VSMC) remodeling. We investigated the contribution of mechanical stretch to insulin-induced VSMC proliferation. Thymidine incorporation was stimulated by insulin in stretched VSMCs, but not in un-stretched VSMCs. Insulin increased 2-deoxy-glucose incorporation in both stretched and un-stretched VSMCs. Mechanical stretch augmented insulin-induced extracellular signal-regulated kinase (ERK) and Akt phosphorylation. Inhibitors of epidermal growth factor (EGF) receptor tyrosine kinase and Src attenuated insulin-induced ERK and Akt phosphorylation, as well as thymidine incorporation, whereas 2-deoxy-glucose incorporation was not affected by these inhibitors. Moreover, stretch augmented insulin-like growth factor (IGF)-1 receptor expression, although it did not alter the expression of insulin receptor and insulin receptor substrate-1. Insulin-induced ERK and Akt activation, and thymidine incorporation were inhibited by siRNA for the IGF-1 receptor. Mechanical stretch augments insulin-induced VSMC proliferation via upregulation of IGF-1 receptor, and downstream Src/EGF receptor-mediated ERK and Akt activation. Similar to in vitro experiment, IGF-1 receptor expression was also augmented in hypertensive rats. These results provide a basis for clarifying the molecular mechanisms of vascular remodeling in hypertensive patients with hyperinsulinemia. -- Highlights: → Mechanical stretch augments insulin-induced VSMC proliferation via IGF-1 receptor. → Src/EGFR-mediated ERK and Akt phosphorylation are augmented in stretched VSMCs. → Similar to in vitro experiment, IGF-1 receptor is increased in hypertensive rats. → Results provide possible mechanisms of vascular remodeling in hypertension with DM.

  2. Mechanical stretch augments insulin-induced vascular smooth muscle cell proliferation by insulin-like growth factor-1 receptor

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Gang [Department of Pharmacology, Faculty of Medicine, Kagawa University, Kagawa (Japan); Department of Anesthesiology, First Affiliated Hospital of China Medical University, Shenyang (China); Hitomi, Hirofumi, E-mail: hitomi@kms.ac.jp [Department of Pharmacology, Faculty of Medicine, Kagawa University, Kagawa (Japan); Hosomi, Naohisa [Department of Cardiorenal and Cerebrovascular Medicine, Faculty of Medicine, Kagawa University, Kagawa (Japan); Lei, Bai; Nakano, Daisuke [Department of Pharmacology, Faculty of Medicine, Kagawa University, Kagawa (Japan); Deguchi, Kazushi; Mori, Hirohito; Masaki, Tsutomu [Department of Gastroenterology and Neurology, Faculty of Medicine, Kagawa University, Kagawa (Japan); Ma, Hong [Department of Anesthesiology, First Affiliated Hospital of China Medical University, Shenyang (China); Griendling, Kathy K. [Department of Medicine, Division of Cardiology, Emory University School of Medicine, Atlanta, GA (United States); Nishiyama, Akira [Department of Pharmacology, Faculty of Medicine, Kagawa University, Kagawa (Japan)

    2011-10-15

    Insulin resistance and hypertension have been implicated in the pathogenesis of cardiovascular disease; however, little is known about the roles of insulin and mechanical force in vascular smooth muscle cell (VSMC) remodeling. We investigated the contribution of mechanical stretch to insulin-induced VSMC proliferation. Thymidine incorporation was stimulated by insulin in stretched VSMCs, but not in un-stretched VSMCs. Insulin increased 2-deoxy-glucose incorporation in both stretched and un-stretched VSMCs. Mechanical stretch augmented insulin-induced extracellular signal-regulated kinase (ERK) and Akt phosphorylation. Inhibitors of epidermal growth factor (EGF) receptor tyrosine kinase and Src attenuated insulin-induced ERK and Akt phosphorylation, as well as thymidine incorporation, whereas 2-deoxy-glucose incorporation was not affected by these inhibitors. Moreover, stretch augmented insulin-like growth factor (IGF)-1 receptor expression, although it did not alter the expression of insulin receptor and insulin receptor substrate-1. Insulin-induced ERK and Akt activation, and thymidine incorporation were inhibited by siRNA for the IGF-1 receptor. Mechanical stretch augments insulin-induced VSMC proliferation via upregulation of IGF-1 receptor, and downstream Src/EGF receptor-mediated ERK and Akt activation. Similar to in vitro experiment, IGF-1 receptor expression was also augmented in hypertensive rats. These results provide a basis for clarifying the molecular mechanisms of vascular remodeling in hypertensive patients with hyperinsulinemia. -- Highlights: {yields} Mechanical stretch augments insulin-induced VSMC proliferation via IGF-1 receptor. {yields} Src/EGFR-mediated ERK and Akt phosphorylation are augmented in stretched VSMCs. {yields} Similar to in vitro experiment, IGF-1 receptor is increased in hypertensive rats. {yields} Results provide possible mechanisms of vascular remodeling in hypertension with DM.

  3. Immediate effects of quantified hamstring stretching: hold-relax proprioceptive neuromuscular facilitation versus static stretching.

    Science.gov (United States)

    Puentedura, Emilio J; Huijbregts, Peter A; Celeste, Shelley; Edwards, Dale; In, Alastair; Landers, Merrill R; Fernandez-de-Las-Penas, Cesar

    2011-08-01

    To compare the immediate effects of a hold-relax proprioceptive neuromuscular facilitation stretching (HR-PNF) versus static stretch (SS) on hamstring flexibility in healthy, asymptomatic subjects. Thirty subjects (13 female; mean age 25.7 ± 3.0, range 22-37) without excessive hamstring muscle flexibility were randomly assigned to one of two stretch groups: HR-PNF or SS. The left leg was treated as a control and did not receive any intervention. The right leg was measured for ROM pre- and post-stretch interventions, with subjects receiving randomly assigned interventions one week apart. Data were analyzed with a 3 (intervention: HR-PNF, SS, control) × 2 (time: pre and post) factorial ANOVA with repeated measures and appropriate post-hoc analyses. A significant interaction was observed between intervention and time for hamstring extensibility, F(2,58) = 25.229, p < .0005. Main effect of intervention for the tested leg was not significant, p = .782 indicating that there was no difference between the two stretch conditions. However, main effect for time was significant (p < .0005), suggesting that hamstring extensibility (for both stretching conditions) after intervention was greater than before. No significant differences were found when comparing the effectiveness of HR-PNF and SS techniques. Both stretching methods resulted in significant immediate increases in hamstring length. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Predictability of Forced Lorenz Systems

    Science.gov (United States)

    Li, Baosheng; Ding, Ruiqiang; Li, Jianping; Zhong, Quanjia

    2017-04-01

    Based on the nonlinear local Lyapunov exponent (NLLE) approach, the influences of external forcing on the predictability are studied in the Lorenz systems with constant and quasi-periodic forces in this paper. The results indicate that for the Lorenz systems with constant and quasi-periodic forces, their predictability limits increase with the forcing strength. With the same magnitude and different directions, the constant or quasi-periodic forcing shows different effects on the predictability limit in the Lorenz system, and these effects become significant with the increase of the forcing strength. Generally speaking, the positive forcing leads to a higher predictability limit than the negative forcing. Therefore, when we think about the effects of positive and negative elements and phases in the atmosphere and ocean research, the predictability problems driven by different phases should be considered separately. In addition, the influences of constant and quasi-periodic forces on the predictability are different in the Lorenz system. The effect of the constant forcing on the predictability is mainly reflected in the linear phase of error growth, while the nonlinear phase should also be considered for the situation of the quasi-periodic forcing. The predictability limit of the system under constant forcing is longer than the system under quasi-periodic forcing. These results based on simple chaotic model could provide insight into the studies of the actual atmosphere predictability.

  5. Stretch-stimulated glucose transport in skeletal muscle is regulated by Rac1

    Science.gov (United States)

    Sylow, Lykke; Møller, Lisbeth L V; Kleinert, Maximilian; Richter, Erik A; Jensen, Thomas E

    2015-01-01

    An alternative to the canonical insulin signalling pathway for glucose transport is muscle contraction/exercise. Mechanical stress is an integrated part of the muscle contraction/relaxation cycle, and passive stretch stimulates muscle glucose transport. However, the signalling mechanism regulating stretch-stimulated glucose transport is not well understood. We recently reported that the actin cytoskeleton regulating GTPase, Rac1, was activated in mouse muscle in response to stretching. Rac1 is a regulator of contraction- and insulin-stimulated glucose transport, however, its role in stretch-stimulated glucose transport and signalling is unknown. We therefore investigated whether stretch-induced glucose transport in skeletal muscle required Rac1 and the actin cytoskeleton. We used muscle-specific inducible Rac1 knockout mice as well as pharmacological inhibitors of Rac1 and the actin cytoskeleton in isolated soleus and extensor digitorum longus muscles. In addition, the role of Rac1 in contraction-stimulated glucose transport during conditions without mechanical load on the muscles was evaluated in loosely hanging muscles and muscles in which cross-bridge formation was blocked by the myosin ATPase inhibitors BTS and Blebbistatin. Knockout as well as pharmacological inhibition of Rac1 reduced stretch-stimulated glucose transport by 30–50% in soleus and extensor digitorum longus muscle. The actin depolymerizing agent latrunculin B similarly decreased glucose transport in response to stretching by 40–50%. Rac1 inhibition reduced contraction-stimulated glucose transport by 30–40% in tension developing muscle but did not affect contraction-stimulated glucose transport in muscles in which force development was prevented. Our findings suggest that Rac1 and the actin cytoskeleton regulate stretch-stimulated glucose transport and that Rac1 is a required part of the mechanical stress-component of the contraction-stimulus to glucose transport in skeletal muscle. Key

  6. Acute muscle and joint mechanical responses following a high-intensity stretching protocol.

    Science.gov (United States)

    Freitas, Sandro R; Andrade, Ricardo J; Nordez, Antoine; Mendes, Bruno; Mil-Homens, Pedro

    2016-08-01

    A previous study observed a joint passive torque increase above baseline ~30 min after a high-intensity stretching. This study examined the effect of a high-intensity stretching on ankle dorsiflexion passive torque, medial gastrocnemius (MG) shear modulus, and plantar flexors maximal voluntary isometric force (MVIC). Participants (n = 11, age 27.2 ± 6.5 years, height 172.0 ± 10.0 cm, weight 69.5 ± 10.4 kg) underwent two stretching sessions with plantar flexors isometric contractions performed: (1) 5 min before, 1 min after, and every 10 min after stretching (MVC session); (2) 5 min before, and 60 min after the stretching (no-MVC session). In both sessions, no changes were observed for MG shear modulus (p > 0.109). In the no-MVC session, passive torque decreased 1 min after stretching (-7.5 ± 8.4 %, p = 0.015), but increased above baseline 30 min after stretching (+6.3 ± 9.3 %, p = 0.049). In the MVC session, passive torque decreased at 1 min (-10.1 ± 6.3 %, p stretching, whereas the MVIC decreased at 1 min (-5.0 ± 9.3 %, p = 0.04) and 10 min (-6.7 ± 8.7 %, p = 0.02) after stretching. The ankle passive torque increase 30 min following the stretch was not due to the MG shear modulus response; consequently, response may be due to changes in surrounding connective tissue mechanical properties.

  7. Differential effects of 30- vs. 60-second static muscle stretching on vertical jump performance.

    Science.gov (United States)

    Pinto, Matheus D; Wilhelm, Eurico N; Tricoli, Valmor; Pinto, Ronei S; Blazevich, Anthony J

    2014-12-01

    It has been proposed that pre-exercise static stretching may reduce muscle force and power. Recent systematic and meta-analytical reviews have proposed a threshold regarding the effect of short (stretching durations on subsequent performance in a multi-joint task (e.g., jump performance), although its effect on power output remains less clear. Furthermore, no single experimental study has explicitly compared the effect of short (e.g., 30 seconds) and moderate (60 seconds) durations of continuous static stretching on multi-joint performance. Therefore, the aim of the present study was determine the effect of acute short- and moderate-duration continuous stretching interventions on vertical jump performance and power output. Sixteen physically active men (21.0 ± 1.9 years; 1.7 ± 0.1 m; 78.4 ± 12.1 kg) volunteered for the study. After familiarization, subjects attended the laboratory for 3 testing sessions. In the nonstretching (NS) condition, subjects performed a countermovement jump (CMJ) test without a preceding stretching bout. In the other 2 conditions, subjects performed 30-second (30SS; 4 minutes) or 60-second (60SS; 8 minutes) static stretching bouts in calf muscles, hamstrings, gluteus maximus, and quadriceps, respectively, followed by the CMJ test. Results were compared by repeated-measures analysis of variance. In comparison with NS, 60SS resulted in a lower CMJ height (-3.4%, p ≤ 0.05) and average (-2.7%, p ≤ 0.05) and peak power output (-2.0%, p ≤ 0.05), but no difference was observed between 30SS and the other conditions (p > 0.05). These data suggest a dose-dependent effect of stretching on muscular performance, which is in accordance with previous studies. The present results suggest a threshold of continuous static stretching in which muscular power output in a multi-joint task may be impaired immediately following moderate-duration (60 seconds; 8 minutes) static stretching while short-duration (30 seconds; 4 minutes) stretching has a

  8. The Hubble Constant

    Directory of Open Access Journals (Sweden)

    Neal Jackson

    2015-09-01

    Full Text Available I review the current state of determinations of the Hubble constant, which gives the length scale of the Universe by relating the expansion velocity of objects to their distance. There are two broad categories of measurements. The first uses individual astrophysical objects which have some property that allows their intrinsic luminosity or size to be determined, or allows the determination of their distance by geometric means. The second category comprises the use of all-sky cosmic microwave background, or correlations between large samples of galaxies, to determine information about the geometry of the Universe and hence the Hubble constant, typically in a combination with other cosmological parameters. Many, but not all, object-based measurements give H_0 values of around 72–74 km s^–1 Mpc^–1, with typical errors of 2–3 km s^–1 Mpc^–1. This is in mild discrepancy with CMB-based measurements, in particular those from the Planck satellite, which give values of 67–68 km s^–1 Mpc^–1 and typical errors of 1–2 km s^–1 Mpc^–1. The size of the remaining systematics indicate that accuracy rather than precision is the remaining problem in a good determination of the Hubble constant. Whether a discrepancy exists, and whether new physics is needed to resolve it, depends on details of the systematics of the object-based methods, and also on the assumptions about other cosmological parameters and which datasets are combined in the case of the all-sky methods.

  9. Spaces of constant curvature

    CERN Document Server

    Wolf, Joseph A

    2010-01-01

    This book is the sixth edition of the classic Spaces of Constant Curvature, first published in 1967, with the previous (fifth) edition published in 1984. It illustrates the high degree of interplay between group theory and geometry. The reader will benefit from the very concise treatments of riemannian and pseudo-riemannian manifolds and their curvatures, of the representation theory of finite groups, and of indications of recent progress in discrete subgroups of Lie groups. Part I is a brief introduction to differentiable manifolds, covering spaces, and riemannian and pseudo-riemannian geomet

  10. Realistic searches on stretched exponential networks

    Indian Academy of Sciences (India)

    Vol. 71, No. 2. — journal of. August 2008 physics pp. 313–317. Realistic searches on stretched exponential networks. PARONGAMA SEN. Department of Physics, University of Calcutta, 92 Acharya Prafulla Chandra Road,. Kolkata 700 009, India .... [4] S Milgram, Psychology Today 1, 60 (1967). J Travers and S Milgram, ...

  11. Filament stretching rheometry of polymer melts

    DEFF Research Database (Denmark)

    Hassager, Ole; Nielsen, Jens Kromann; Rasmussen, Henrik Koblitz

    2005-01-01

    The Filament Stretching Rheometry (FSR) method developed by Sridhar, McKinley and coworkers for polymer solutions has been extended to be used also for polymer melts. The design of a melt-FSR will be described and differences to conventional melt elongational rheometers will be pointed out. Results...

  12. Cloud Network Helps Stretch IT Dollars

    Science.gov (United States)

    Collins, Hilton

    2012-01-01

    No matter how many car washes or bake sales schools host to raise money, adding funds to their coffers is a recurring problem. This perpetual financial difficulty makes expansive technology purchases or changes seem like a pipe dream for school CIOs and has education technologists searching for ways to stretch money. In 2005, state K-12 school…

  13. The stretch zone of automotive steel sheets

    Indian Academy of Sciences (India)

    on steel grade, on the rolling direction as well as on the loading rate. Stretch zones ... This interaction is demonstrated at a fracture surface as a bounded transition between initiatory crack (e.g., fatigue) and either ... The materials examined in this study are three grades of thin automotive steel sheets: XSG,. HR 45 and DP.

  14. Fractional behaviour at cyclic stretch-bending

    NARCIS (Netherlands)

    Emmens, W.C.; van den Boogaard, Antonius H.; Kazantzis, A.V.; de Hosson, J.Th.M.; Kolleck, R

    2010-01-01

    The fractional behaviour at cyclic stretch-bending has been studied by performing tensile tests at long specimens that are cyclically bent at the same time, on mild steel, dual-phase steel, stainless steel, aluminium and brass. Several types of fracture are observed, these are discussed, as are the

  15. Automation of a single-DNA molecule stretching device

    DEFF Research Database (Denmark)

    Sørensen, Kristian Tølbøl; Lopacinska, Joanna M.; Tommerup, Niels

    2015-01-01

    We automate the manipulation of genomic-length DNA in a nanofluidic device based on real-time analysis of fluorescence images. In our protocol, individual molecules are picked from a microchannel and stretched with pN forces using pressure driven flows. The millimeter-long DNA fragments free...... flowing in micro- and nanofluidics emit low fluorescence and change shape, thus challenging the image analysis for machine vision. We demonstrate a set of image processing steps that increase the intrinsically low signal-to-noise ratio associated with single-molecule fluorescence microscopy. Furthermore......, we demonstrate how to estimate the length of molecules by continuous real-time image stitching and how to increase the effective resolution of a pressure controller by pulse width modulation. The sequence of image-processing steps addresses the challenges of genomic-length DNA visualization; however...

  16. Infrared laser spectroscopy of the n-propyl and i-propyl radicals: Stretch-bend Fermi coupling in the alkyl CH stretch region

    Science.gov (United States)

    Franke, Peter R.; Tabor, Daniel P.; Moradi, Christopher P.; Douberly, Gary E.; Agarwal, Jay; Schaefer, Henry F.; Sibert, Edwin L.

    2016-12-01

    The n-propyl and i-propyl radicals were generated in the gas phase via pyrolysis of n-butyl nitrite [CH3(CH2)3ONO] and i-butyl nitrite [(CH3)2CHCH2ONO], respectively. Nascent radicals were promptly solvated by a beam of He nanodroplets, and the infrared spectra of the radicals were recorded in the CH stretching region. Several previously unreported bands are observed between 2800 and 3150 cm-1. The CH stretching modes observed above 3000 cm-1 are in excellent agreement with CCSD(T) anharmonic frequencies computed using second-order vibrational perturbation theory. However, between 2800 and 3000 cm-1, the spectra of n- and i-propyl radicals become congested and difficult to assign due to the presence of multiple anharmonic resonance polyads. To model the spectrally congested region, Fermi and Darling-Dennison resonances are treated explicitly using "dressed" Hamiltonians and CCSD(T) quartic force fields in the normal mode representation, and the agreement with experiment is less than satisfactory. Computations employing local mode effective Hamiltonians reveal the origin of the spectral congestion to be strong coupling between the high frequency CH stretching modes and the lower frequency CHn bending/scissoring motions. The most significant coupling is between stretches and bends localized on the same CH2/CH3 group. Spectral simulations using the local mode approach are in excellent agreement with experiment.

  17. Role of nesprin-1 in nuclear deformation in endothelial cells under static and uniaxial stretching conditions

    International Nuclear Information System (INIS)

    Anno, Toshiro; Sakamoto, Naoya; Sato, Masaaki

    2012-01-01

    Highlights: ► Nesprin-1 knockdown decreases widths of nuclei in ECs under static condition. ► Nuclear strain caused by stretching is increased by nesprin-1 knockdown in ECs. ► We model mechanical interactions of F-actin with the nucleus in stretched cells. ► F-actin bound to nesprin-1 may cause sustainable force transmission to the nucleus. -- Abstract: The linker of nucleus and cytoskeleton (LINC) complex, including nesprin-1, has been suggested to be crucial for many biological processes. Previous studies have shown that mutations in nesprin-1 cause abnormal cellular functions and diseases, possibly because of insufficient force transmission to the nucleus through actin filaments (F-actin) bound to nesprin-1. However, little is known regarding the mechanical interaction between the nucleus and F-actin through nesprin-1. In this study, we examined nuclear deformation behavior in nesprin-1 knocked-down endothelial cells (ECs) subjected to uniaxial stretching by evaluating nuclear strain from lateral cross-sectional images. The widths of nuclei in nesprin-1 knocked-down ECs were smaller than those in wild-type cells. In addition, nuclear strain in nesprin-1 knocked-down cells, which is considered to be compressed by the actin cortical layer, increased compared with that in wild-type cells under stretching condition. These results indicate that nesprin-1 knockdown releases the nucleus from the tension of F-actin bound to the nucleus, thereby increasing allowance for deformation before stretching, and that F-actin bound to the nucleus through nesprin-1 causes sustainable force transmission to the nucleus.

  18. EFFECTIVENESS OF PNF STRETCHING AND CYCLIC STRETCHING OF CALF TIGHTNESS ON COLLEGE GOING GIRLS

    Directory of Open Access Journals (Sweden)

    Ashlesha Sirari

    2015-06-01

    Full Text Available Background: Flexibility helps with injury prevention, the reduction of soreness following a workout, and a general sense of well-being. There are different stretching techniques and protocols for improvements in calf extensibility and flexibility. The purpose of the study was to investigate the effectiveness of two techniques i.e. CYCLIC and PNF stretching which improves calf flexibility. This study was done to find the effectiveness of calf Cyclic and PNF stretching technique to improve calf flexibility. Methods: 30 subjects with age group 21-22 years were randomly allocated to 2 groups equally. Group 1(n=15 were given CYCLIC and group 2(n=15 were given PNF stretching technique. Plantar flexion was used to measure the calf tightness which was done before and after the treatment. Treatment was given for 7 days and on the 7th day the calf tightness was again measured. Results: The mean difference of the CYCLIC is 4.6 and mean difference of PNF is 4.7 which indicate that CYCLIC and PNF both are effective to improve calf flexibility but PNF is more effective than CYCLIC to improve calf flexibility. Conclusion: The neurophysiological basis of PNF, stating that the excitatory efficient of the neuromuscular spindle or the inhibitory afferent of the Golgi tendon organ (GTO or both are responsible for the effects. During PNF stretch and isometric contraction of stretched agonists for extended period may cause activation of its neuromuscular spindle. The increase in tension created during the isometric contraction of the pre – lengthened agonist contracts concentrically. Both the fascia & the spindle of the agonist adjust to the nearly lengthened position. These impulses travel via causing post synaptic inhibition of the motor neuron to agonist increasing the tension from the GTO. These impulses can override the impulses coming from the neuromuscular spindles arousing the muscle to reflexly resist to the change in length, thus helping in lengthening

  19. Un saludo constante

    OpenAIRE

    Salcedo Ortega, Manuela; Pontificia Universidad Javeriana, Cali

    2013-01-01

    La presencia familiar estará siempre en mi vida: Creo que esa unión va más allá de los lazos que creamos en ese primer abrir de ojos del nacimiento pues los lazos se fortalecen con el tiempo. Es que esos lazos van de la genética al riñón y puede que suene muy raro, pero esta es mi enfermedad, la primera y la constante, la que desaparece y reaparece, la heredada y la que cada vez que me saluda, deja su huella. Comenzó hace 16 años. Mis infecciones urinarias fueron el comienzo de muchas maluque...

  20. The Hubble Constant

    Directory of Open Access Journals (Sweden)

    Jackson Neal

    2007-09-01

    Full Text Available I review the current state of determinations of the Hubble constant, which gives the length scale of the Universe by relating the expansion velocity of objects to their distance. In the last 20 years, much progress has been made and estimates now range between 60 and 75 km s^-1 Mpc^-1, with most now between 70 and 75 km s^-1 Mpc^-1, a huge improvement over the factor-of-2 uncertainty which used to prevail. Further improvements which gave a generally agreed margin of error of a few percent rather than the current 10% would be vital input to much other interesting cosmology. There are several programmes which are likely to lead us to this point in the next 10 years.

  1. Constant Proportion Portfolio Insurance

    DEFF Research Database (Denmark)

    Jessen, Cathrine

    2014-01-01

    Portfolio insurance, as practiced in 1987, consisted of trading between an underlying stock portfolio and cash, using option theory to place a floor on the value of the position, as if it included a protective put. Constant Proportion Portfolio Insurance (CPPI) is an option-free variation...... on the theme, originally proposed by Fischer Black. In CPPI, a financial institution guarantees a floor value for the “insured” portfolio and adjusts the stock/bond mix to produce a leveraged exposure to the risky assets, which depends on how far the portfolio value is above the floor. Plain-vanilla portfolio...... insurance largely died with the crash of 1987, but CPPI is still going strong. In the frictionless markets of finance theory, the issuer’s strategy to hedge its liability under the contract is clear, but in the real world with transactions costs and stochastic jump risk, the optimal strategy is less obvious...

  2. Passive Stretch Versus Active Stretch on Intervertebral Movement in Non - Specific Neck Pain

    International Nuclear Information System (INIS)

    Abd El - Aziz, A.H.; Amin, D.I.; Moustafa, I.

    2016-01-01

    Neck pain is one of the most common and painful musculoskeletal conditions. Point prevalence ranges from 6% to 22% and up to 38% of the elderly population, while lifetime prevalence ranges from 14,2% to 71%. Up till now no randomized study showed the effect between controversy of active and passive stretch on intervertebral movement. The purpose: the current study was to investigate the effect of the passive and active stretch on intervertebral movement in non - specific neck pain. Material and methods: Forty five subjects from both sexes with age range between 18 and 30 years and assigned in three groups, group I (15) received active stretch, ultrasound and TENS. Group II (15) received passive stretch, ultrasound and TENS. Group III (15) received ultrasound and TENS. The radiological assessment was used to measure rotational and translational movement of intervertebral movement before and after treatment. Results: MANOVA test was used for radiological assessment before and after treatment there was significant increase in intervertebral movement in group I as p value =0.0001. Conclusion: active stretch had a effect in increasing the intervertebral movement compared to the passive stretch

  3. How to Stretch Your Ankle After a Sprain

    Science.gov (United States)

    ... Ankle After A Sprain How to Stretch Your Ankle After A Sprain Page Content You should perform the following stretches ... Consider these home exercises when recuperating from an ankle sprain. Perform them twice per day. While seated, bring ...

  4. Effects of a short proprioceptive neuromuscular facilitation stretching bout on quadriceps neuromuscular function, flexibility, and vertical jump performance.

    Science.gov (United States)

    Place, Nicolas; Blum, Yannick; Armand, Stéphane; Maffiuletti, Nicola A; Behm, David G

    2013-02-01

    The inclusion of relatively long bouts of stretching (repeated static stretches of ∼30 seconds) in the warm-up is usually associated with a drop in muscle performance. The purpose of this study was to assess the effect of a novel self-administered proprioceptive neuromuscular facilitation (PNF) paradigm with short periods of stretching and contraction on quadriceps neuromuscular function, vertical jump performance, and articular range of motion (ROM). Twelve healthy men (age: 27.7 ± 7.3 years, height: 178.4 ± 10.4 cm, weight: 73.8 ± 16.9 kg) volunteered to participate in a PNF session and a control session separated by 2-7 days. The PNF stretching lasted 2 minutes and consisted of 4 sets of 5-second isometric hamstring contraction immediately followed by 5 seconds of passive static stretch of the quadriceps immediately followed by 5 seconds isometric quadriceps contraction for each leg. For the control session, the participants were asked to walk at a comfortable speed for 2 minutes. Active ROM of knee flexion, vertical jump performance, and quadriceps neuromuscular function were tested before, immediately after, and 15 minutes after the intervention. The PNF stretching procedure did not affect ROM, squat jump, and countermovement jump performances. Accordingly, we did not observe any change in maximal voluntary contraction force, voluntary activation level, M-wave and twitch contractile properties that could be attributed to PNF stretching. The present self-administered PNF stretching of the quadriceps with short (5-second) stretches is not recommended before sports where flexibility is mandatory for performance.

  5. Development of Functional Recovery Training Device for Hemiplegic Fingers with Finger-expansion Facilitation Exercise by Stretch Reflex

    Science.gov (United States)

    Yu, Yong; Iwashita, Hisashi; Kawahira, Kazumi; Hayashi, Ryota

    This paper develops a functional recovery training device to perform repetition facilitating exercise for hemiplegic finger rehabilitation. On the facilitation exercise, automatic finger expansion can be realized and facilitated by stretch reflex, where a stimulation forces is applied instantaneously on flexion finger for making strech reflex and resistance forces are applied for maintaining the strech reflex. In this paper, novel parallel mechanisms, force sensing system with high sensitivity and resistance accompanying cooperation control method are proposed for sensing, controlling and realizing the stimulation force, resistance forces, strech reflex and repetition facilitating exercise. The effectivities and performances of the device are shown by some experiments.

  6. Maximum tension: with and without a cosmological constant

    Science.gov (United States)

    Barrow, John D.; Gibbons, G. W.

    2015-02-01

    We discuss various examples and ramifications of the conjecture that there exists a maximum force (or tension) in general relativistic systems. We contrast this situation with that in Newtonian gravity, where no maximum force exists, and relate it to the existence of natural units defined by constants of Nature and the fact that the Planck units of force and power do not depend on the Planck constant. We discuss how these results change in higher dimensions where the Planck units of force are no longer non-quantum. We discuss the changes that might occur to the conjecture if a positive cosmological constant exists and derive a maximum force bound using the Kottler-Schwarzschild-de Sitter black hole.

  7. Transparent conducting film: Effect of mechanical stretching to ...

    Indian Academy of Sciences (India)

    Administrator

    posite was fixed to a tabletop clamp and unidirectionally stretched after cutting the paper support at two opposite sides. To hold the film under the stretched condition, both edges of stretched CNT-mat/transparent-film composite was then adhered to a PMMA substrate by epoxy glue and both the sheet resistance and the ...

  8. Effects of dynamic stretches on Isokinetic hamstring and Quadriceps ...

    African Journals Online (AJOL)

    In conclusion, dynamic stretches have positive effects on muscle strength, H/Q ratios and ROM. Therefore, dynamic stretches may increase performance and reduce the risk of injury to athletes. Keywords: Quadriceps; Hamstrings; Muscles Isokinetic; Dynamic stretches. South African Journal for Research in Sport, Physical ...

  9. An Intelligent Computerized Stretch Reflex Measurement System For Clinical And Investigative Neurology

    Science.gov (United States)

    Flanagan, P. M.; Chutkow, J. G.; Riggs, M. T.; Cristiano, V. D.

    1987-05-01

    We describe the design of a reliable, user-friendly preprototype system for quantifying the tendon stretch reflexes in humans and large mammals. A hand-held, instrumented reflex gun, the impactor of which contains a single force sensor, interfaces with a computer. The resulting test system can deliver sequences of reproducible stimuli at graded intensities and adjustable durations to a muscle's tendon ("tendon taps"), measure the impacting force of each tap, and record the subsequent reflex muscle contraction from the same tendon -- all automatically. The parameters of the reflex muscle contraction include latency; mechanical threshold; and peak time, peak magnitude, and settling time. The results of clinical tests presented in this paper illustrate the system's potential usefulness in detecting neurologic dysfunction affecting the tendon stretch reflexes, in documenting the course of neurologic illnesses and their response to therapy, and in clinical and laboratory neurologic research.

  10. String Stretching, Frequency Modulation, and Banjo Clang

    OpenAIRE

    Politzer, David

    2014-01-01

    The banjo’s floating bridge, string break angle, and flexible drumhead all contribute to substantial audio range frequency modulation. From the world of electronic music synthesis, it is known that modulating higher frequency sounds with lower acoustic frequencies leads to metallic and bell-like tone. The mechanics of the banjo does just that quite naturally, modulating fundamentals and harmonics with the motion of the bridge. In technical terms, with a floating bridge, string stretching is f...

  11. The stretch zone of automotive steel sheets

    Indian Academy of Sciences (India)

    The stretch zone of automotive steel sheets. L' AMBRIŠKO1,∗ and L PEŠEK2. 1Institute of Structural Engineering, Faculty of Civil Engineering,. Technical University of Košice, Vysokoškolská 4, 042 00 Košice, Slovak Republic. 2Department of Materials Science, Faculty of Metallurgy,. Technical University of Košice, Letná 9, ...

  12. The effects of isometric resistance training on stretch reflex induced tremor in the knee extensor muscles.

    Science.gov (United States)

    Durbaba, Rade; Cassidy, Angela; Budini, Francesco; Macaluso, Andrea

    2013-06-15

    This study examines the effect of 4 wk of high-intensity isometric resistance training on induced tremor in knee extensor muscles. Fourteen healthy volunteers were assigned to either the training group (n = 7) or the nontraining control group (n = 7). Induced tremor was assessed by measuring force fluctuations during anisometric contractions against spring loading, whose compliance was varied to allow for preferential activation of the short or long latency stretch reflex components. Effects of high-intensity isometric resistance training on induced tremor was assessed under two contraction conditions: relative force matching, where the relative level of activity was equal for both pre- and post-training sessions, set at 30% maximum voluntary contraction (MVC), and absolute force matching, where the level of activity was set to 30% pretrained MVC. The training group experienced a 26.5% increase in MVC in contrast to the 0.8% for the control group. For relative force-matching contractions, induced tremor amplitude and frequency did not change in either the training or control group. During absolute force-matching contractions, induced tremor amplitude was decreased by 37.5% and 31.6% for the short and long components, respectively, with no accompanying change in frequency, for the training group. No change in either measure was observed in the control group for absolute force-matching contractions. The results are consistent with high-intensity isometric resistance training induced neural changes leading to increased strength, coupled with realignment of stretch reflex automatic gain compensation to the new maximal force output. Also, previous reported reductions in anisometric tremor following strength training may partly be due to changed stretch reflex behavior.

  13. Spontaneous bending of pre-stretched bilayers.

    Science.gov (United States)

    DeSimone, Antonio

    2018-01-01

    We discuss spontaneously bent configurations of pre-stretched bilayer sheets that can be obtained by tuning the pre-stretches in the two layers. The two-dimensional nonlinear plate model we use for this purpose is an adaptation of the one recently obtained for thin sheets of nematic elastomers, by means of a rigorous dimensional reduction argument based on the theory of Gamma-convergence (Agostiniani and DeSimone in Meccanica. doi:10.1007/s11012-017-0630-4, 2017, Math Mech Solids. doi:10.1177/1081286517699991, arXiv:1509.07003, 2017). We argue that pre-stretched bilayer sheets provide us with an interesting model system to study shape programming and morphing of surfaces in other, more complex systems, where spontaneous deformations are induced by swelling due to the absorption of a liquid, phase transformations, thermal or electro-magnetic stimuli. These include bio-mimetic structures inspired by biological systems from both the plant and the animal kingdoms.

  14. Dynamics and structure of stretched flames

    Energy Technology Data Exchange (ETDEWEB)

    Law, C.K. [Princeton Univ., NJ (United States)

    1993-12-01

    This program aims to gain fundamental understanding on the structure, geometry, and dynamics of laminar premixed flames, and relate these understanding to the practical issues of flame extinction and stabilization. The underlying fundamental interest here is the recent recognition that the response of premixed flames can be profoundly affected by flame stretch, as manifested by flow nonuniformity, flame curvature, and flame/flow unsteadiness. As such, many of the existing understanding on the behavior of premixed flames need to be qualitatively revised. The research program consists of three major thrusts: (1) detailed experimental and computational mapping of the structure of aerodynamically-strained planar flames, with emphasis on the effects of heat loss, nonequidiffusion, and finite residence time on the flame thickness, extent of incomplete reaction, and the state of extinction. (2) Analytical study of the geometry and dynamics of stretch-affected wrinkled flame sheets in simple configurations, as exemplified by the Bunsen flame and the spatially-periodic flame, with emphasis on the effects of nonlinear stretch, the phenomena of flame cusping, smoothing, and tip opening, and their implications on the structure and burning rate of turbulent flames. (3) Stabilization and blowoff of two-dimensional inverted premixed and stabilization and determining the criteria governing flame blowoff. The research is synergistically conducted through the use of laser-based diagnostics, computational simulation of the flame structure with detailed chemistry and transport, and mathematical analysis of the flame dynamics.

  15. Short Durations of Static Stretching when Combined with Dynamic Stretching do not Impair Repeated Sprints and Agility

    Science.gov (United States)

    Wong, Del P.; Chaouachi, Anis; Lau, Patrick W.C.; Behm, David G.

    2011-01-01

    This study aimed to compare the effect of different static stretching durations followed by dynamic stretching on repeated sprint ability (RSA) and change of direction (COD). Twenty-five participants performed the RSA and COD tests in a randomized order. After a 5 min aerobic warm up, participants performed one of the three static stretching protocols of 30 s, 60 s or 90 s total duration (3 stretches x 10 s, 20 s or 30 s). Three dynamic stretching exercises of 30 s duration were then performed (90 s total). Sit-and-reach flexibility tests were conducted before the aerobic warm up, after the combined static and dynamic stretching, and post- RSA/COD test. The duration of static stretching had a positive effect on flexibility with 36.3% and 85.6% greater sit-and-reach scores with the 60 s and 90 s static stretching conditions respectively than with the 30 s condition (p ≤ 0.001). However there were no significant differences in RSA and COD performance between the 3 stretching conditions. The lack of change in RSA and COD might be attributed to a counterbalancing of static and dynamic stretching effects. Furthermore, the short duration (≤ 90 s) static stretching may not have provided sufficient stimulus to elicit performance impairments. Key points The duration of combined static and dynamic stretching had a positive effect on flexibility with 36.3% and 85.6% greater sit and reach scores with the 60 s and 90 s static stretching conditions respectively than with the 30 s condition (p ≤ 0.001). No significant differences in RSA and COD between the 3 stretching conditions. The lack of change in RSA and COD might be attributed to a counterbalancing of static and dynamic stretching effects. The short duration (≤ 90 s) static stretching may not have provided sufficient stimulus to elicit performance impairments. PMID:24149890

  16. Does adding mobilization to stretching improve outcomes for people with frozen shoulder? A randomized controlled clinical trial.

    Science.gov (United States)

    Çelik, Derya; Kaya Mutlu, Ebru

    2016-08-01

    To assess the effectiveness of joint mobilization combined with stretching exercises in patients with frozen shoulder. A randomized controlled clinical pilot trial. Department of Orthopedics and Traumatology. Thirty patients with frozen shoulder. All participants were randomly assigned to one of two treatment groups: joint mobilization and stretching versus stretching exercises alone. Both groups performed a home exercise program and were treated for six weeks (18 sessions). The primary outcome measures for functional assessment were the Disabilities of the Arm, Shoulder and Hand score and the Constant score. The secondary outcome measures were pain level, as evaluated with a visual analog scale, and range of motion, as measured using a conventional goniometer. Patients were assessed before treatment, at the end of the treatment, and after one year as follow-up. Two-by-two repeated-measures ANOVA with Bonferroni corrections revealed significant increases in abduction (91.9° [CI: 86.1-96.7] to 172.8° [CI: 169.7-175.5]), external rotation (28.1° [CI: 22.2-34.2] to 77.7° [CI: 70.3-83.0]) and Constant score (39.1 [CI: 35.3-42.6] to 80.5 [75.3-86.6]) at the one-year follow-up in the joint mobilization combined with stretching exercise group, whereas the group performing stretching exercise alone did not show such changes. In the treatment of patients with frozen shoulder, joint mobilization combined with stretching exercises is better than stretching exercise alone in terms of external rotation, abduction range of motion and function score. © The Author(s) 2015.

  17. Training specific adaptations of H- and stretch reflexes in human soleus muscle

    OpenAIRE

    Gruber, Markus; Taube, Wolfgang; Gollhofer, Albert; Beck, Sandra; Amtage, Florian; Schubert, Martin

    2007-01-01

    The authors investigated the effect of physical exercise on reflex excitability in a controlled intervention study. Healthy participants (N = 21) performed 4 weeks of either power training (ballistic strength training) or balance training (sensorimotor training [SMT]). Both training regimens enhanced balance control and rate of force development, whereas reductions in peak-to-peak amplitudes of stretch reflexes and in the ratio of the maximum Hoffman reflex to the maximum efferent motor respo...

  18. Regional Climate Simulation with a Variable Resolution Stretch Grid GCM: The 1998 Summer Drought

    Science.gov (United States)

    Fox-Rabinovitz, Michael; Stein, Uri; Takacs, Lawrence; Govindaraju, Ravi; Suarez, Max

    1999-01-01

    The variable resolution stretched grid(SG) GCM based on the Goddard Earth Observing System (GEOS) GCM, has been developed and tested in a regional climate simulation mode. The GEOS SG-GCM is used for simulation of the 1988 summer drought over the U.S. Midwest. Within the stretched grid, the region of interest with a uniform about 60 km resolution is a rectangle over the U.S. Outside the region, the grid intervals increase or stretch with a constant stretching factor (as a geometric progression). The results of two-month simulation for the anomalous climate event of the U.S. drought of 1988, are validated against data analysis fields and diagnostics. The event has been chosen by the Project to Inter-compare Regional Climate Simulations(PIRCS). The efficient regional down-scaling as well as the positive impact of fine regional resolution, are obtained. More specifically, the precipitation, 500 hPa, and low-level jet patterns and characteristics are well represented in the simulation. The SG-concept appeared to be a promising candidate for regional and subregional climate studies and applications.

  19. Beyond the Hubble Constant

    Science.gov (United States)

    1995-08-01

    about the distances to galaxies and thereby about the expansion rate of the Universe. A simple way to determine the distance to a remote galaxy is by measuring its redshift, calculate its velocity from the redshift and divide this by the Hubble constant, H0. For instance, the measured redshift of the parent galaxy of SN 1995K (0.478) yields a velocity of 116,000 km/sec, somewhat more than one-third of the speed of light (300,000 km/sec). From the universal expansion rate, described by the Hubble constant (H0 = 20 km/sec per million lightyears as found by some studies), this velocity would indicate a distance to the supernova and its parent galaxy of about 5,800 million lightyears. The explosion of the supernova would thus have taken place 5,800 million years ago, i.e. about 1,000 million years before the solar system was formed. However, such a simple calculation works only for relatively ``nearby'' objects, perhaps out to some hundred million lightyears. When we look much further into space, we also look far back in time and it is not excluded that the universal expansion rate, i.e. the Hubble constant, may have been different at earlier epochs. This means that unless we know the change of the Hubble constant with time, we cannot determine reliable distances of distant galaxies from their measured redshifts and velocities. At the same time, knowledge about such change or lack of the same will provide unique information about the time elapsed since the Universe began to expand (the ``Big Bang''), that is, the age of the Universe and also its ultimate fate. The Deceleration Parameter q0 Cosmologists are therefore eager to determine not only the current expansion rate (i.e., the Hubble constant, H0) but also its possible change with time (known as the deceleration parameter, q0). Although a highly accurate value of H0 has still not become available, increasing attention is now given to the observational determination of the second parameter, cf. also the Appendix at the

  20. The Relevance of Stretch Intensity and Position: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Nikos eApostolopoulos

    2015-08-01

    Full Text Available Stretching exercises to increase the range of motion (ROM of joints have been used by sports coaches and medical professionals for improving performance and rehabilitation. The ability of connective and muscular tissues to change their architecture in response to stretching is important for their proper function, repair and performance. Given the dearth of relevant data in the literature, this review examined two key elements of stretching: stretch intensity and stretch position; and their significance to ROM, delayed onset muscle soreness (DOMS, and inflammation in different populations. A search of three databases, Pub-Med, Google Scholar, and Cochrane Reviews, identified 152 articles, which were subsequently categorized into four groups; athletes (n = 24, clinical (n = 29, elderly (n = 12, and general population (n = 87. The use of different populations facilitated a wider examination of the stretching components and their effects. All 152 articles incorporated information regarding duration, frequency and stretch position, whereas only 79 referred to the intensity of stretching and 22 of these 79 studies were deemed high quality. It appears that the intensity of stretching is relatively under-researched, and the importance of body position and its influence on stretch intensity, is largely unknown. In conclusion, this review has highlighted areas for future research, including stretch intensity and position and their effect on musculo-tendinous tissue, in relation to the sensation of pain, delayed onset muscle soreness, inflammation, as well as muscle health and performance

  1. SHORT DURATIONS OF STATIC STRETCHING WHEN COMBINED WITH DYNAMIC STRETCHING DO NOT IMPAIR REPEATED SPRINTS AND AGILITY

    OpenAIRE

    Del P. Wong; Anis Chaouachi; Patrick W.C. Lau; David G. Behm

    2011-01-01

    This study aimed to compare the effect of different static stretching durations followed by dynamic stretching on repeated sprint ability (RSA) and change of direction (COD). Twenty-five participants performed the RSA and COD tests in a randomized order. After a 5 min aerobic warm up, participants performed one of the three static stretching protocols of 30 s, 60 s or 90 s total duration (3 stretches x 10 s, 20 s or 30 s). Three dynamic stretching exercises of 30 s duration were then performe...

  2. Efficacy of static stretching and proprioceptive neuromuscular facilitation stretch on hamstrings length after a single session.

    Science.gov (United States)

    O'Hora, John; Cartwright, Abigail; Wade, Clive D; Hough, Alan D; Shum, Gary L K

    2011-06-01

    A number of studies have investigated the efficacy of several repetitions of proprioceptive neuromuscular facilitation stretching (PNF) and static stretching (SS). However, there is limited research comparing the effects of a single bout of these stretching maneuvers. The aim of this study was to compare the effectiveness of a single bout of a therapist-applied 30-second SS vs. a single bout of therapist-applied 6-second hamstring (agonist) contract PNF. Forty-five healthy subjects between the ages of 21 and 35 were randomly allocated to 1 of the 2 stretching groups or a control group, in which no stretching was received. The flexibility of the hamstring was determined by a range of passive knee extension, measured using a universal goniometer, with the subject in the supine position and the hip at 90° flexion, before and after intervention. A significant increase in knee extension was found for both intervention groups after a single stretch (SS group = 7.53°, p < 0.01 and PNF group = 11.80°, p < 0.01). Both interventions resulted in a significantly greater increase in knee extension when compared to the control group (p < 0.01). The PNF group demonstrated significantly greater gains in knee extension compared to the SS group (mean difference 4.27°, p < 0.01). It can be concluded that a therapist applied SS or PNF results in a significant increase in hamstring flexibility. A hamstring (agonist) contract PNF is more effective than an SS in a single stretching session. These findings are important to physiotherapists or trainers working in clinical and sporting environments. Where in the past therapists may have spent time conducting multiple repetitions of a PNF and an SS, a single bout of either technique may be considered just as effective. A key component of the study methodology was the exclusion of a warm-up period before stretching. Therefore, the findings of efficacy of a single PNF are of particular relevance in sporting environments and busy clinical

  3. SHORT DURATIONS OF STATIC STRETCHING WHEN COMBINED WITH DYNAMIC STRETCHING DO NOT IMPAIR REPEATED SPRINTS AND AGILITY

    Directory of Open Access Journals (Sweden)

    Del P. Wong

    2011-06-01

    Full Text Available This study aimed to compare the effect of different static stretching durations followed by dynamic stretching on repeated sprint ability (RSA and change of direction (COD. Twenty-five participants performed the RSA and COD tests in a randomized order. After a 5 min aerobic warm up, participants performed one of the three static stretching protocols of 30 s, 60 s or 90 s total duration (3 stretches x 10 s, 20 s or 30 s. Three dynamic stretching exercises of 30 s duration were then performed (90 s total. Sit-and-reach flexibility tests were conducted before the aerobic warm up, after the combined static and dynamic stretching, and post- RSA/COD test. The duration of static stretching had a positive effect on flexibility with 36.3% and 85.6% greater sit-and-reach scores with the 60 s and 90 s static stretching conditions respectively than with the 30 s condition (p < 0.001. However there were no significant differences in RSA and COD performance between the 3 stretching conditions. The lack of change in RSA and COD might be attributed to a counterbalancing of static and dynamic stretching effects. Furthermore, the short duration (< 90 s static stretching may not have provided sufficient stimulus to elicit performance impairments

  4. To Stretch and Search for Better Ways

    Science.gov (United States)

    Moore, John W.

    2000-06-01

    There's a lot to do to get each issue of this Journal ready for publication, and there's a lot that can go awry during that process. We the editorial staff do our utmost to make certain that each issue is the best it can possibly be, but, of necessity, a lot of our effort is focused on solving problems, correcting errors, and avoiding pitfalls. It is not surprising that we sometimes lose sight of the bigger picture--all of the things that came out as well as or better than we hoped they would. Therefore it gives us great pleasure when a reader applauds (and thereby rewards) our efforts. One such communication inspired this editorial. I have appreciated the extra effort put forward by the staff to make the Journal really come alive. The high quality of the Journal serves as an incentive to chemical educators to stretch and search for better ways to inspire our students. I fervently hope that we do encourage you "to stretch and search for better ways", not only to inspire students but in everything you do. Stretching and searching for better ways is what life, science, chemistry, and teaching are all about, and it is a wonderfully stimulating and exciting way to approach anything and everything. Sometimes, though, one's ability to stretch is akin to that of a rubber band exposed too long to sunlight. Change becomes a threat or a burden instead of an opportunity. This often happens in one area but not others, as in the case of someone doing original research but whose lecture notes are yellow with age, or someone who experiments with new teaching approaches but neglects the latest chemical discoveries. Whatever its manifestation, failure to stretch and search for better ways is a great loss, both for the individual directly involved and for others. Fortunately there are many who continually stretch and search, often in conjunction with JCE. For example, some time ago the Chair of the Board of Publication, Jerry Bell, challenged Journal readers to become Journal

  5. Optical stretching on chip with acoustophoretic prefocusing

    DEFF Research Database (Denmark)

    Khoury Arvelo, Maria; Laub Busk, L.; Bruus, Henrik

    2012-01-01

    prefocusing. This focusing mechanism aims for target particles to always ow in the correct height relative to the optical stretcher, and is induced by a piezo-electric ultrasound transducer attached underneath the chip and driven at a frequency leading to a vertical standing ultrasound wave...... in the microchannel. Trapping and manipulation is demonstrated for dielectric beads. In addition, we show trapping, manipulation and stretching of red blood cells and vesicles, whereby we extract the elastic properties of these objects. Our design points towards the construction of a low-cost, high-throughput lab-on-a-chip...

  6. Viscous flows stretching and shrinking of surfaces

    CERN Document Server

    Mehmood, Ahmer

    2017-01-01

    This authored monograph provides a detailed discussion of the boundary layer flow due to a moving plate. The topical focus lies on the 2- and 3-dimensional case, considering axially symmetric and unsteady flows. The author derives a criterion for the self-similar and non-similar flow, and the turbulent flow due to a stretching or shrinking sheet is also discussed. The target audience primarily comprises research experts in the field of boundary layer flow, but the book will also be beneficial for graduate students.

  7. A tunable hemispherical platform for non-stretching curved flexible electronics and optoelectronics

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Jinda; Ju, Y. Sungtaek, E-mail: just@seas.ucla.edu [Mechanical and Aerospace Engineering Department, University of California, 420 Westwood Plaza, Los Angeles, California 90095 (United States)

    2014-07-28

    One major challenge in incorporating flexible electronics or optoelectronics on curved surfaces is the requirement of significant stretchability. We report a tunable platform for incorporating flexible and yet non-stretching device layers on a hemisphere. In this configuration, an array of planar petals contractively maps onto the surface of an inflatable hemisphere through elastocapillary interactions mediated by an interface liquid. A mechanical model is developed to elucidate the dependence of the conformality of the petal structures on their elastic modulus and thickness and the liquid surface tension. The modeling results are validated against experimental results obtained using petal structures of different thicknesses, restoring elastic spring elements of different spring constants, and liquids with different surface tension coefficients. Our platform will enable facile integration of non-stretching electronic and optoelectronic components prepared using established planar fabrication techniques on tunable hemispherical surfaces.

  8. Complex myograph allows the examination of complex muscle contractions for the assessment of muscle force, shortening, velocity, and work in vivo

    Directory of Open Access Journals (Sweden)

    Ruhschulte Hainer

    2008-07-01

    Full Text Available Abstract Background The devices used for in vivo examination of muscle contractions assess only pure force contractions and the so-called isokinetic contractions. In isokinetic experiments, the extremity and its muscle are artificially moved with constant velocity by the measuring device, while a tetanic contraction is induced in the muscle, either by electrical stimulation or by maximal voluntary activation. With these systems, experiments cannot be performed at pre-defined, constant muscle length, single contractions cannot be evaluated individually and the separate examination of the isometric and the isotonic components of single contractions is not possible. Methods The myograph presented in our study has two newly developed technical units, i.e. a. a counterforce unit which can load the muscle with an adjustable, but constant force and b. a length-adjusting unit which allows for both the stretching and the contraction length to be infinitely adjustable independently of one another. The two units support the examination of complex types of contraction and store the counterforce and length-adjusting settings, so that these conditions may be accurately reapplied in later sessions. Results The measurement examples presented show that the muscle can be brought to every possible pre-stretching length and that single isotonic or complex isometric-isotonic contractions may be performed at every length. The applied forces act during different phases of contraction, resulting into different pre- and after-loads that can be kept constant – uninfluenced by the contraction. Maximal values for force, shortening, velocity and work may be obtained for individual muscles. This offers the possibility to obtain information on the muscle status and to monitor its changes under non-invasive measurement conditions. Conclusion With the Complex Myograph, the whole spectrum of a muscle's mechanical characteristics may be assessed.

  9. Dynamics of the OH stretching mode in crystalline Ba(ClO4)2.3H2O

    Science.gov (United States)

    Hutzler, Daniel; Brunner, Christian; Petkov, Petko St.; Heine, Thomas; Fischer, Sighart F.; Riedle, Eberhard; Kienberger, Reinhard; Iglev, Hristo

    2018-02-01

    The vibrational dynamics of the OH stretching mode in Ba(ClO4)2 trihydrate are investigated by means of femtosecond infrared spectroscopy. The sample offers plane cyclic water trimers in the solid phase that feature virtually no hydrogen bond interaction between the water molecules. Selective excitation of the symmetric and asymmetric stretching leads to fast population redistribution, while simultaneous excitation yields quantum beats, which are monitored via a combination tone that dominates the overtone spectrum. The combination of steady-state and time-resolved spectroscopy with quantum chemical simulations and general theoretical considerations gives indication of various aspects of symmetry breakage. The system shows a joint population lifetime of 8 ps and a long-lived coherence between symmetric and asymmetric stretching, which decays with a time constant of 0.6 ps.

  10. Statistics of force networks

    Science.gov (United States)

    Tighe, Brian

    2009-03-01

    We study the statistics of contact forces in the force network ensemble, a minimal model of jammed granular media that emphasizes the role of vector force balance. We show that the force probability distribution can be calculated analytically by way of an analogy to equilibrium ensemble methods. In two dimensions the large force tail decays asymptotically as a Gaussian, distinct from earlier predictions, due to the existence of a conserved quantity related to the presence of local vector force balance. We confirm our predictions with highly accurate statistical sampling -- we sample the force distribution over more than 40 decades -- permitting unambiguous confrontation of theory with numerics. We show how the conserved quantity arises naturally within the context of any constant stress ensemble.

  11. Stretched exponential relaxation in molecular and electronic glasses

    International Nuclear Information System (INIS)

    Phillips, J.C.

    1996-01-01

    Stretched exponential relaxation, exp[-(t/τ) β ], fits many relaxation processes in disordered and quenched electronic and molecular systems, but it is widely believed that this function has no microscopic basis, especially in the case of molecular relaxation. For electronic relaxation the appearance of the stretched exponential is often described in the context of dispersive transport, where β is treated as an adjustable parameter, but in almost all cases it is generally assumed that no microscopic meaning can be assigned to 0 g , a glass transition temperature. We show that for molecular relaxation β(T g ) can be understood, providing that one separates extrinsic and intrinsic effects, and that the intrinsic effects are dominated by two magic numbers, β SR =3/5 for short-range forces, and β K =3/7 for long-range Coulomb forces, as originally observed by Kohlrausch for the decay of residual charge on a Leyden jar. Our mathematical model treats relaxation kinetics using the Lifshitz-Kac-Luttinger diffusion to traps depletion model in a configuration space of effective dimensionality, the latter being determined using axiomatic set theory and Phillips-Thorpe constraint theory. The experiments discussed include ns neutron scattering experiments, particularly those based on neutron spin echoes which measure S(Q, t) directly, and the traditional linear response measurements which span the range from μs to s, as collected and analysed phenomenologically by Angell, Ngai, Boehmer and others. The electronic materials discussed include a-Si:H, granular C 60 , semiconductor nanocrystallites, charge density waves in TaS 3 , spin glasses, and vortex glasses in high-temperature semiconductors. The molecular materials discussed include polymers, network glasses, electrolytes and alcohols, Van der Waals supercooled liquids and glasses, orientational glasses, water, fused salts, and heme proteins. In the intrinsic cases the theory of β(T g ) is often accurate to 2%, which

  12. Stability constants of the Europium complexes with the chloride ions; Constantes de estabilidad de los complejos del europio con los iones cloruro

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez R, M.; Solache R, M.; Rojas H, A. [Instituto Nacional de Investigaciones Nucleares, Departamento de Quimica, A.P. 18-1027, C.P. 11801 Mexico D.F. (Mexico)

    2000-07-01

    The stability constants of lanthanides complexes with chloride ions which were determined at the same ionic force but in different media, are significantly different. It does not exist a systematic study over these stability constants. The purpose of this work is to determine the stability constants of the europium complexes with chloride ions at 303 K, by the solvents extraction method. (Author)

  13. Effects of stretching the scalene muscles on slow vital capacity.

    Science.gov (United States)

    Lee, Juncheol; Hwang, Sehee; Han, Seungim; Han, Dongwook

    2016-06-01

    [Purpose] The purpose of this study was to examine whether stretching of the scalene muscles would improve slow vital capacity (SVC). [Subjects and Methods] The subjects of this study were 20 healthy female students to whom the study's methods and purpose were explained and their agreement for participation was obtained. The SVC was measured using spirometry (Pony FX, COSMED Inc., Italy). The intervention used was stretching of the scalene muscles. Stretching was carried out for 15 min, 10 times at per each portion of scalene muscles: the anterior, middle, and posterior parts. [Results] Expiratory vital capacity (EVC) and tidal volume (Vt) noticeably increased after stretching. However, there were no changes in any of the SVC items in the control group. [Conclusion] This study demonstrated that stretching of the scalene muscles can effectively improve SVC. In particular, we confirmed that stretching of the scalene muscles was effective in increasing EVC and Vt, which are items of SVC.

  14. Mechanical stretch influence on lifetime of dielectric elastomer films

    Science.gov (United States)

    Iannarelli, A.; Niasar, M. Ghaffarian

    2017-04-01

    Film pre-stretching is a widely adopted solution to improve dielectric strength of the DEA systems. However, to date, long term reliability of this solution has not been investigated. In this work it is explored how the dielectric elastomer lifetime is affected by film pre-stretching. The dielectric loss of soft polydimethylsiloxane (PDMS) films is studied for different stretch ratios by measuring tanδ. Additionally, time-to-breakdown was measured at DC electric stress for different stretch ratios. For this purpose, accelerated life test (ALT) were performed. The results obtained are compared with non-pre-stretched samples. This study suggests that no additional dielectric losses are caused by film stretching up to 80% of original dimensions.

  15. Proprioceptive neuromuscular facilitation stretching : mechanisms and clinical implications.

    Science.gov (United States)

    Sharman, Melanie J; Cresswell, Andrew G; Riek, Stephan

    2006-01-01

    Proprioceptive neuromuscular facilitation (PNF) stretching techniques are commonly used in the athletic and clinical environments to enhance both active and passive range of motion (ROM) with a view to optimising motor performance and rehabilitation. PNF stretching is positioned in the literature as the most effective stretching technique when the aim is to increase ROM, particularly in respect to short-term changes in ROM. With due consideration of the heterogeneity across the applied PNF stretching research, a summary of the findings suggests that an 'active' PNF stretching technique achieves the greatest gains in ROM, e.g. utilising a shortening contraction of the opposing muscle to place the target muscle on stretch, followed by a static contraction of the target muscle. The inclusion of a shortening contraction of the opposing muscle appears to have the greatest impact on enhancing ROM. When including a static contraction of the target muscle, this needs to be held for approximately 3 seconds at no more than 20% of a maximum voluntary contraction. The greatest changes in ROM generally occur after the first repetition and in order to achieve more lasting changes in ROM, PNF stretching needs to be performed once or twice per week. The superior changes in ROM that PNF stretching often produces compared with other stretching techniques has traditionally been attributed to autogenic and/or reciprocal inhibition, although the literature does not support this hypothesis. Instead, and in the absence of a biomechanical explanation, the contemporary view proposes that PNF stretching influences the point at which stretch is perceived or tolerated. The mechanism(s) underpinning the change in stretch perception or tolerance are not known, although pain modulation has been suggested.

  16. Diffusion constant of slowly rotating black three-brane

    Science.gov (United States)

    Amoozad, Z.; Sadeghi, J.

    2018-01-01

    In this paper, we take the slowly rotating black three-brane background and perturb it by introducing a vector gauge field. We find the components of the gauge field through Maxwell equations and Bianchi identities. Using currents and some ansatz we find Fick's first law at long wavelength regime. An interesting result for this non-trivial supergravity background is that the diffusion constant on the stretched horizon which emerges from Fick's first law is a complex constant. The pure imaginary part of the diffusion constant appears because the black three-brane has angular momentum. By taking the static limit of the corresponding black brane the well known diffusion constant will be recovered. On the other hand, from the point of view of the Fick's second law, we have the dispersion relation ω = - iDq2 and we found a damping of hydrodynamical flow in the holographically dual theory. Existence of imaginary term in the diffusion constant introduces an oscillating propagation of the gauge field in the dual field theory.

  17. PRELIMINARY STUDIES OF RIVETED JOINTS AT FEED FORCE

    Directory of Open Access Journals (Sweden)

    Radosław Bielawski

    2015-08-01

    Full Text Available The aim of the study was to determine the feasibility of riveted joints in composites materials. Static tensile test method was used. In the test one type of glass fabric was used (Interglas 92140 from which two types of composite samples were prepared. In each sample the same type of fiber with the same fiber orientation – 3 layers - was used. The samples had dimensions of 100×100 mm and thickness of approximately 1 mm. The composite probes were located in a metal frame with a screw connection which was made of screws with nominal thread pitch M5. Screws were tightened with constant torque. It was to provide an axial force to the sample during the tensile test. The frame was placed between cross-bars of tensile machine INSTRON 8516. The samples were stretched at a speed of 0.05 mm/s at a distance up to 16 mm. During the tensile test displacement of the samples and pull force were registered. Depending on the fibre orientations and the value of feed force, damage models were described. On the basis of the results the possibility of usage of aluminium rivet nuts connections in composite materials was determined.

  18. Pattern zoology in biaxially pre-stretched elastic bilayers: from wrinkles and creases to fracture-like ridges

    Science.gov (United States)

    Al-Rashed, Rashed; Lopez JiméNez, Francisco; Reis, Pedro

    The wrinkling of elastic bilayers under compression has been explored as a method to produce reversible surface topography, with applications ranging from microfluidics to tunable optics. We introduce a new experimental system to study the effects of pre-stretching on the instability patterns that result from the biaxial compression of thin shells bound to an elastic substrate. A pre-stretched substrate is first prepared by pressurizing an initially flat elastomeric disk and bulging it into a nearly hemispherical thick shell. The substrate is then coated with a thin layer of a polymer suspension, which, upon curing, results in a thin shell of nearly constant thickness. Releasing the pre-stretch in the substrate by deflating the system places the outer film in a state of biaxial compression, resulting in a variety of buckling patterns. We explore the parameter space by systematically varying the pre-stretch, the substrate/film stiffness mismatch, and the thickness of the film. This results in a continuous transition between different buckling patterns, from the dimples and wrinkles that are traditionally associated with the buckling of elastic bilayers, to creases and high aspect ratio `fracture-like' ridges, where the pre-stretch plays an essential role.

  19. Correlation between structure and conductivity in stretched Nafion

    Science.gov (United States)

    Allahyarov, Elshad; Taylor, Philip

    2008-03-01

    We have used coarse-grained simulation methods to investigate the effect of stretching-induced structure orientation on the proton conductivity of Nafion-like polyelectrolyte membranes. Recent experimental data on the morphology of ionomers describe Nafion as an aggregation of polymeric backbone chains forming elongated objects embedded in a continuous ionic medium. Uniaxial stretching of a recast Nafion film causes a preferential orientation of these objects in the direction of stretching. Our simulations of humid Nafion show that this has a strong effect on the proton conductivity, which is enhanced along the stretching direction, while the conductivity perpendicular to the stretched polymer backbone is strongly reduced. Stretching also causes the perfluorinated side chains to orient perpendicular to the stretching axis. The sulphonate multiplets shrink in diameter as the stretching is increased and show a spatially periodic ordering in their distribution. This in turn affects the distribution of contained water at low water contents. The water forms a continuous network with narrow bridges between small water clusters absorbed in head-group multiplets. We find the morphological changes in the stretched Nafion to be retained upon removal of the uniaxial stress.

  20. Spectrophotometric determination of association constant

    DEFF Research Database (Denmark)

    2016-01-01

    Least-squares 'Systematic Trial-and-Error Procedure' (STEP) for spectrophotometric evaluation of association constant (equilibrium constant) K and molar absorption coefficient E for a 1:1 molecular complex, A + B = C, with error analysis according to Conrow et al. (1964). An analysis of the Charg...

  1. Effects of dynamic stretching on strength, muscle imbalance, and muscle activation.

    Science.gov (United States)

    Costa, Pablo B; Herda, Trent J; Herda, Ashley A; Cramer, Joel T

    2014-03-01

    This study aimed to examine the acute effects of dynamic stretching on concentric leg extensor and flexor peak torque, eccentric leg flexor peak torque, and the conventional and functional hamstring-quadriceps (H:Q) ratios. Twenty-one women (mean ± SD age = 20.6 ± 2.0 yr, body mass = 64.5 ± 9.3 kg, height = 164.7 ± 6.5 cm) performed maximal voluntary isokinetic leg extension, flexion, and eccentric hamstring muscle actions at the angular velocities of 60°·s and 180°·s before and after a bout of dynamic hamstring and quadriceps stretching as well as a control condition. Leg flexion peak torque decreased under both control (mean ± SE for 60°s = 75.8 ± 4.0 to 72.4 ± 3.7 N·m, 180°·s = 62.1 ± 3.2 to 59.1 ± 3.1 N·m) and stretching (60°·s = 73.1 ± 3.9 to 65.8 ± 3.3 N·m, 180°·s = 61.2 ± 3.3 to 54.7 ± 2.6 N·m) conditions, whereas eccentric hamstring peak torque decreased only after the stretching (60°·s = 87.3 ± 5.1 to 73.3 ± 3.6 N·m, 180°·s = 89.2 ± 4.4 to 77.0 ± 3.4 N·m) intervention (P ≤ 0.05). Stretching also caused a decrease in conventional H:Q (60°·s = 0.58 ± 0.02 to 0.54 ± 0.02, 180°·s = 0.67 ± 0.02 to 0.61 ± 0.03) and functional H:Q ratios (60°·s = 0.69 ± 0.03 to 0.60 ± 0.03, 180°·s = 1.00 ± 0.06 to 0.60 ± 0.03) (P ≤ 0.05). Because dynamic stretching reduced concentric and eccentric hamstring strength as well as the conventional and functional H:Q ratios, fitness and allied-health professionals may need to be cautious when recommending dynamic rather than static stretching to maintain muscle force.

  2. Effects of contract-relax vs static stretching on stretch-induced strength loss and length-tension relationship

    DEFF Research Database (Denmark)

    Balle, S S; Magnusson, S P; McHugh, M P

    2015-01-01

    The purpose of this study was to determine the acute effects of contract-relax stretching (CRS) vs static stretching (SS) on strength loss and the length-tension relationship. We hypothesized that there would be a greater muscle length-specific effect of CRS vs SS. Isometric hamstring strength...... loss compared with SS. These results support the use of SS for stretching the hamstrings....

  3. EFFECTIVENESS OF PNF STRETCHING VERSUS STATIC STRETCHING ON PAIN AND HAMSTRING FLEXIBILITY FOLLOWING MOIST HEAT IN INDIVIDUALS WITH KNEE OSTEOARTHRITIS

    Directory of Open Access Journals (Sweden)

    Meena .V

    2016-10-01

    Full Text Available Background: Osteoarthritis (OA is a degenerative joint disease and one of the major public health problem that causesfunctional impairment and reduced quality of life. To compare the effectiveness of PNF Hold relax stretching versus Static stretching on pain and flexibility of hamstring following moist heat in individuals with knee osteoarthritis. Hamstring tightness is the major problem in knee osteoarthritis individuals. Therefore the need of study is comparing the effectiveness of PNF Hold relax stretching versus static stretching on pain and flexibility of hamstrings following moist heat in knee osteoarthritis participants. Determining the effects of PNF Hold relax stretching versus Static stretching along with moist heat on pain and hamstring flexibility by VAS and Active knee extension range of motion in knee osteoarthritis individuals. Methods: 30 subjects with symptoms of knee osteoarthritis were randomly distributed into 2 groups 15 in each group. PNF Hold relax stretching along with moist heat is compared to Static stretching along with moist heat. Pain was measured by Visual Analogue Scale (VAS and hamstring flexibility by Active knee Extension Range of Motion (AKEROM by universal goniometer. Measurements are taken pre and post intervention. Results: The results indicated PNF Hold relax stretching along with moist heat showed a statistically significant improvement in pain (p<0.05 and improvement in hamstring flexibility (p<0.05 when compared to Static stretching along with moist heat. Conclusion: Subjects with PNF Hold relax stretching along with moist heat showed significant improvement in pain reduction and improving hamstring flexibility than Static stretching along with moist heat.

  4. The effect of warm-up, static stretching and dynamic stretching on hamstring flexibility in previously injured subjects

    OpenAIRE

    O'Sullivan, Kieran; Murray, Elaine; Sainsbury, David

    2009-01-01

    Abstract Background Warm-up and stretching are suggested to increase hamstring flexibility and reduce the risk of injury. This study examined the short-term effects of warm-up, static stretching and dynamic stretching on hamstring flexibility in individuals with previous hamstring injury and uninjured controls. Methods A randomised crossover study design, over 2 separate days. Hamstring flexibility was assessed using passive knee extension range of motion (PKE ROM). 18 previously injured indi...

  5. LABOR GYMNASTICS: STRETCHING EXERCISE X FLEXIONAMENT

    Directory of Open Access Journals (Sweden)

    Jacqueline Amorin Anchieta Borges da Silva, Isabel Cristina Taranto e Fernanda Piasecki

    2006-12-01

    Full Text Available Nowadays, there are many opportunities for the society to live a healthful and long life. At the same time, never people was so sedentary and without harmony. Without a healthy body and with “an occupied mind” the human loses exactly what more it needs: the disposal to produce, to coexist and to live a good life. In this context, the present research aimed to revise some terms related to labor gymnastics, which is focused in the prevention of risks related to hours of working and in the reduction of muscular tension levels that may be originated during a day of work. Thus, the present study will make a differentiation between the use of stretching and flexionament during labor gymnastic sessions.

  6. Stretched Lens Array Photovoltaic Concentrator Technology Developed

    Science.gov (United States)

    Piszczor, Michael F., Jr.; O'Neill, Mark J.

    2004-01-01

    Solar arrays have been and continue to be the mainstay in providing power to nearly all commercial and government spacecraft. Light from the Sun is directly converted into electrical energy using solar cells. One way to reduce the cost of future space power systems is by minimizing the size and number of expensive solar cells by focusing the sunlight onto smaller cells using concentrator optics. The stretched lens array (SLA) is a unique concept that uses arched Fresnel lens concentrators to focus sunlight onto a line of high-efficiency solar cells located directly beneath. The SLA concept is based on the Solar Concentrator Array with Refractive Linear Element Technology (SCARLET) design that was used on NASA's New Millennium Deep Space 1 mission. The highly successful asteroid/comet rendezvous mission (1998 to 2001) demonstrated the performance and long-term durability of the SCARLET/SLA solar array design and set the foundation for further improvements to optimize its performance.

  7. Aerothermodynamic properties of stretched flames in enclosures

    Science.gov (United States)

    Rotman, D. A.; Oppenheim, A. K.

    Flames are stretched by being pulled along their frontal surface by the flow field in which they reside. Their trajectories tend to approach particle paths, acquiring eventually the role of contact boundaries, -interfaces between the burnt and unburnt medium that may broaden solely as a consequence of diffusion. Fundamental properties of flow fields governing such flames are determined here on the basis of the zero Mach number model, providng a rational method of approach to the computational analysis of combustion fields in enclosures where, besides the aerodynamic properties flow, the thermodynamic process of compression must be taken into account. To illustrate its application, the method is used to reveal the mechanism of formation of a tulip-shape flame in a rectangular enclosure under nonturbulent flow conditions.

  8. Electroforesis of Whey and Stretching Water Protein of Mozzarella Cheese Production from Factorial Experimental of Coagulation and Stretching Temperature

    Directory of Open Access Journals (Sweden)

    Purwadi Purwadi

    2012-02-01

    Full Text Available The use of lime juice as acidifier in the making of Mozzarella cheese was aimed to learn the protein profile of whey and stretching water produced with treatment of coagulation and stretching temperature. The treatment of coagulation temperature was G1 = 30oC, G2 = 35oC, G3 = 40oC, and G4 = 45oC, and the treatment of stretching temperature was M1 = 70oC, M2 = 75oC, M3 = 80oC, and M4 = 85oC. The research result showed that coagulation temperature of 30 and 35 oC gave the same protein profile of whey as well as coagulation temperature of 40 and 45oC, while coagulation temperature of 30 and 35oC with coagulation temperatur of 40 and 45oC gave different protein profile of whey. Different coagulation temperature gave different protein profile of whey and stretching water, while different stretching temperature gave the same protein profile of stretching water. Coagulation temperature of 30 and 35oC gave the same protein profile of stretching water as well as coagulation temperature of 40 and 45oC, while coagulation temperature of 30 and 35oC with temperature of 40 and 45oC gave different protein profile of stretching water. Keywords: protein profile, Mozzarella cheese, coagulation temperature, stretching temperature

  9. EFFICACY OF MODIFIED PROPRIOCEPTIVE NEUROMUSCULAR FACILITATION STRETCHING WITH CRYOTHERAPY OVER MANUAL PASSIVE STRETCHING WITH CRYOTHERAPY ON HAMSTRING FLEXIBILITY

    Directory of Open Access Journals (Sweden)

    Shamik Bhattacharjee

    2016-04-01

    Full Text Available Background: Healthy individuals, to ease and accomplish their activities of daily living they need flexible body without any tightness in the muscles, particularly those used for a definite function. Cooling soft tissues in a lengthened position after stretching has been shown to promote more lasting increases in soft tissue length and minimize post stretch muscle soreness. There are less documented studies which compared modified proprioceptive neuromuscular facilitation (PNF stretch over passive manual stretch with cold application commonly after the interventions. Methods: Thirty high school going healthy students were divided into two groups- Group I received Passive Manual stretching (n=15 and Group II received modified PNF stretching (n=15 and both groups received cold application after the interventions for 10 minutes commonly for 5 days. ROM was taken on day 1, day 5 and day 7. Results: After day 7, Group II with Modified PNF stretching along with cold application showed a significant increase in range of motion tested with active knee extension test (AKET. Conclusion: Modified PNF stretching is considered to be the effective intervention in increasing and maintaining ROM in AKET over passive manual stretching with cold applications commonly after the interventions.

  10. Immediate Effects of Proprioceptive Neuromuscular Facilitation Stretching Programs Compared With Passive Stretching Programs for Hamstring Flexibility: A Critically Appraised Topic.

    Science.gov (United States)

    Hill, Kristian J; Robinson, Kendall P; Cuchna, Jennifer W; Hoch, Matthew C

    2017-11-01

    Clinical Scenario: Increasing hamstring flexibility through clinical stretching interventions may be an effective means to prevent hamstring injuries. However the most effective method to increase hamstring flexibility has yet to be determined. For a healthy individual, are proprioceptive neuromuscular facilitation (PNF) stretching programs more effective in immediately improving hamstring flexibility when compared with static stretching programs? Summary of Key Findings: A thorough literature search returned 195 possible studies; 5 studies met the inclusion criteria and were included. Current evidence supports the use of PNF stretching or static stretching programs for increasing hamstring flexibility. However, neither program demonstrated superior effectiveness when examining immediate increases in hamstring flexibility. Clinical Bottom Line: There were consistent findings from multiple low-quality studies that indicate there is no difference in the immediate improvements in hamstring flexibility when comparing PNF stretching programs to static stretching programs in physically active adults. Strength of Recommendation: Grade B evidence exists that PNF and static stretching programs equally increase hamstring flexibility immediately following the stretching program.

  11. Thin film flow along a periodically-stretched elastic beam

    Science.gov (United States)

    Boamah Mensah, Chris; Chini, Greg; Jensen, Oliver

    2017-11-01

    Motivated by an application to pulmonary alveolar micro-mechanics, a system of partial differential equations is derived that governs the motion of a thin liquid film lining both sides of an inertia-less elastic substrate. The evolution of the film mass distribution is described by invoking the usual lubrication approximation while the displacement of the substrate is determined by employing a kinematically nonlinear Euler-Bernoulli beam formulation. In the parameter regime of interest, the axial strain can be readily shown to be a linear function of arc-length specified completely by the motion of ends of the substrate. In contrast, the normal force balance on the beam yields an equation for the substrate curvature that is fully coupled to the time-dependent lubrication equation. Linear analyses of both a stationary and periodically-stretched flat substrate confirm the potential for buckling instabilities and reveal an upper bound on the dimensionless axial stiffness for which the coupled thin-film/inertial-less-beam model is well-posed. Numerical simulations of the coupled system are used to explore the nonlinear development of the buckling instabilities.

  12. The constant composition method for crystallization of calcium carbonate at constant supersaturation

    Science.gov (United States)

    Beck, R.; Seiersten, M.; Andreassen, J.-P.

    2013-10-01

    The exact control of supersaturation is of great importance when studying the formation of crystalline and amorphous matter. The constant composition method is suitable for the study of crystallization processes at constant supersaturation by controlled addition of titrants to a crystallizer to maintain constant pH. Not all aspects necessary for successful operation of this method are obvious from the existing literature, and the method is often used in an incorrect way. The focus of the present work is to highlight pitfalls associated with the constant composition method. The method is assessed and described in detail to show that even if the solution pH is kept constant, the supersaturation may change. First and foremost, it is illustrated how crucial it is to use a chemical composition of the titrant solutions which is in accordance with the initially prepared aqueous solution. General rules are presented for carbonates as to how the composition of the titrant solutions should be calculated based on total alkalinity in order to maintain constant supersaturation. This has - to the knowledge of the authors - not been shown before. Then, it is shown how exchange of carbon dioxide with the atmosphere corrupts the constancy of the supersaturation level during an experiment. Third, it is pointed out that the ionic strength should be kept constant throughout crystallization experiments since a change in ionic strength alters the activity of the ions in solution. Here, the determination of the thermodynamic driving force (supersaturation) is explained based on the relevant chemical equilibria, total alkalinity and calculation of the activity coefficients. The calculations are presented for the least stable polymorph of calcium carbonate, vaterite, but can easily be extended to the other polymorphs and other pH-dependent systems allowing for crystallization studies at low and maintained supersaturation levels typical of naturally occurring processes in geology and

  13. Effects of acute stretching on the maximal expression of strength ...

    African Journals Online (AJOL)

    This study compared the effects of four treatments (n = 12 each) [10 minutes of quiet sitting, without stretching (NS); two minutes warm up on an arm ergometer at 25 watts resistance (WU); 10 second-hold static stretching (each) of the shoulder, chest and arm muscle groups (ST10); and two sets of 20 second-hold static ...

  14. The stretch reflex and the contributions of C David Marsden.

    Science.gov (United States)

    Bhattacharyya, Kalyan B

    2017-01-01

    The stretch reflex or myotatic reflex refers to the contraction of a muscle in response to its passive stretching by increasing its contractility as long as the stretch is within physiological limits. For ages, it was thought that the stretch reflex was of short latency and it was synonymous with the tendon reflex, subserving the same spinal reflex arc. However, disparities in the status of the two reflexes in certain clinical situations led Marsden and his collaborators to carry out a series of experiments that helped to establish that the two reflexes had different pathways. That the two reflexes are dissociated has been proved by the fact that the stretch reflex and the tendon reflex, elicited by stimulation of the same muscle, have different latencies, that of the stretch reflex being considerably longer. They hypothesized that the stretch reflex had a transcortical course before it reached the spinal motor neurons for final firing. Additionally, the phenomenon of stimulus-sensitive cortical myoclonus lent further evidence to the presence of the transcortical loop where the EEG correlate preceded the EMG discharge. This concept has been worked out by later neurologists in great detail, and the general consensus is that indeed, the stretch reflex is endowed with a conspicuous transcortical component.

  15. Chaperones in Polyglutamine Aggregation : Beyond the Q-Stretch

    NARCIS (Netherlands)

    Kuiper, E. F. E.; de Mattos, Eduardo P.; Jardim, Laura B.; Kampinga, Harm H.; Bergink, Steven

    2017-01-01

    Expanded polyglutamine (polyQ) stretches in at least nine unrelated proteins lead to inherited neuronal dysfunction and degeneration. The expansion size in all diseases correlates with age at onset (AO) of disease and with polyQ protein aggregation, indicating that the expanded polyQ stretch is the

  16. Stretched exponential relaxation and ac universality in disordered dielectrics

    DEFF Research Database (Denmark)

    Milovanov, Alexander V.; Rypdal, Kristoffer; Juul Rasmussen, Jens

    2007-01-01

    are stretched exponential character of dielectric relaxation, power-law power spectral density, and anomalous dependence of ac conduction coefficient on frequency. We propose a self-consistent model of dielectric relaxation in which the relaxations are described by a stretched exponential decay function...

  17. The stretch reflex and the contributions of C David Marsden

    Directory of Open Access Journals (Sweden)

    Kalyan B Bhattacharyya

    2017-01-01

    Full Text Available The stretch reflex or myotatic reflex refers to the contraction of a muscle in response to its passive stretching by increasing its contractility as long as the stretch is within physiological limits. For ages, it was thought that the stretch reflex was of short latency and it was synonymous with the tendon reflex, subserving the same spinal reflex arc. However, disparities in the status of the two reflexes in certain clinical situations led Marsden and his collaborators to carry out a series of experiments that helped to establish that the two reflexes had different pathways. That the two reflexes are dissociated has been proved by the fact that the stretch reflex and the tendon reflex, elicited by stimulation of the same muscle, have different latencies, that of the stretch reflex being considerably longer. They hypothesized that the stretch reflex had a transcortical course before it reached the spinal motor neurons for final firing. Additionally, the phenomenon of stimulus-sensitive cortical myoclonus lent further evidence to the presence of the transcortical loop where the EEG correlate preceded the EMG discharge. This concept has been worked out by later neurologists in great detail , and the general consensus is that indeed, the stretch reflex is endowed with a conspicuous transcortical component.

  18. Transparent conducting film: Effect of mechanical stretching to ...

    Indian Academy of Sciences (India)

    We describe in this paper a transparent conducting film (TCF). It is a fibrous layer of multiwalled carbon nanotubes (MWNTs), labeled a dilute CNT mat, that was prepared and unidirectionally stretched to improve both the optical and electrical properties. After stretching by 80% strain, transmittance at 550 nm wavelength ...

  19. The effects of acute self myofascial release (MFR) and stretching ...

    African Journals Online (AJOL)

    Baseline measurements were taken initially and then participants were randomly divided into four groups (control [n=10, static stretching [n=10], dynamic stretching [n=10] and self MFR [n=10]). Each group performed a 60-minute intervention. During the intervention programme the various groups took part in prescribed ...

  20. Transparent conducting film: Effect of mechanical stretching to ...

    Indian Academy of Sciences (India)

    Administrator

    The number of pixels inside a rectangle counted on the Adobe Photoshop. Figure 6. Sheet resistance and transmittance at 550 nm wave- length of a dilute CNT mat before and after stretch. Five sam- ples were stretched by 40 and 110% strain respectively and average data is shown in each case. A polyurethane elastomer.

  1. Does Postexercise Static Stretching Alleviate Delayed Muscle Soreness?

    Science.gov (United States)

    Buroker, Katherine C.; Schwane, James A.

    1989-01-01

    Because many experts recommend stretching after exercise to relieve muscle soreness, 23 subjects performed a 30-minute step test to induce delayed muscle soreness. There was neither temporary relief of pain immediately after stretching nor a reduction in pain during the 3-day postexercise period. (Author/SM)

  2. Mechanical stretch influence on lifetime of dielectric elastomer films

    NARCIS (Netherlands)

    Iannarelli, A.; Ghaffarian Niasar, M.; Bar-Cohen, Yoseph

    2017-01-01

    Film pre-stretching is a widely adopted solution to improve dielectric strength of the DEA systems. However, to date, long term reliability of this solution has not been investigated. In this work it is explored how the dielectric elastomer lifetime is affected by film pre-stretching. The dielectric

  3. Vibrational spectra of trimethyl gallium species in relation to the force field and methyl group internal rotation

    Science.gov (United States)

    McKean, D. C.; McQuillan, G. P.; Duncan, J. L.; Shephard, N.; Munro, B.; Fawcett, V.; Edwards, H. G. M.

    Infrared and Raman spectra are reported for Ga(CH 3) 3, Ga(CD 3) 3 and Ga(CHD 2) 3 in the gas phase. These were also examined in the i.r. spectrum in the solid phase at 78 K. The new Raman spectra of the CHD 2 species strongly support earlier i.r. evidence for CH force constant variation during free internal rotation of the methyl groups, from the presence of two bands at 2940 (vs) and 2922 cm -1 (w) identified as due to ν avis and ν †is respectively. The observed a' and e' frequencies of the d0 and d9 species are used to obtain a force field in which three interaction constants are well defined. The best value of the Ga-C stretching force constant is 2.356(28) mdyn Å -1. In the crystal phase at 78 K, the e' modes due to δ s Me and ν as GaC 3 are split, indicating a site group symmetry lower than C3. Gallium and carbon isotope frequency shifts are predicted.

  4. The effect of calf stretching box on stretching calf muscle compliance: a prospective, randomized single-blinded controlled trial.

    Science.gov (United States)

    Chadchavalpanichaya, Navaporn; Srisawasdi, Gulapar; Suwannakin, Atchara

    2010-12-01

    To study the effect of calf stretching box usage in increasing the compliance of performing calf stretching exercise as compared to the conventional exercise method. To study the effect of calf stretching box usage in decreasing the calf muscle tightness and complications as compared to the conventional exercise method. Eighty patients older than 45 years old with calf muscles tightness were enrolled in a prospective, randomized single-blinded controlled trial at the out-patient Rehabilitation medicine clinic, Siriraj Hospital, Bangkok Thailand between April and August 2009. Patients were randomized into two groups, the study group (stretching by using calf stretching box) and the control group (stretching by the conventional exercise method). Patients in both groups were asked to hold the stretch for at least 1 minute and to perform the stretching program at least two times per day, every day for two weeks. Furthermore, they were asked to record the real frequency and duration of their exercise and complications in a logbook every day. Thirty-eight patients in each group completed the study. The baseline characteristics of the patients in both groups were similar. The study group had higher frequency and longer duration of performing calf stretching exercise than the control group. They also reported more decrease of calf muscle tightness with less pain complication (shoulder pain, knee pain, low back pain, and calf muscle pain) than the control group (p calf muscle and degree of ankle range of motion between the two groups. Stretching calf muscle with calf stretching box can increase compliance, decrease calf muscle tightness and decrease complications when compared with the conventional exercise method.

  5. The effect of warm-up, static stretching and dynamic stretching on hamstring flexibility in previously injured subjects.

    Science.gov (United States)

    O'Sullivan, Kieran; Murray, Elaine; Sainsbury, David

    2009-04-16

    Warm-up and stretching are suggested to increase hamstring flexibility and reduce the risk of injury. This study examined the short-term effects of warm-up, static stretching and dynamic stretching on hamstring flexibility in individuals with previous hamstring injury and uninjured controls. A randomised crossover study design, over 2 separate days. Hamstring flexibility was assessed using passive knee extension range of motion (PKE ROM). 18 previously injured individuals and 18 uninjured controls participated. On both days, four measurements of PKE ROM were recorded: (1) at baseline; (2) after warm-up; (3) after stretch (static or dynamic) and (4) after a 15-minute rest. Participants carried out both static and dynamic stretches, but on different days. Data were analysed using Anova. Across both groups, there was a significant main effect for time (p static stretching (p = 0.04) but significantly decreased after dynamic stretching (p = 0.013). The increased flexibility after warm-up and static stretching reduced significantly (p 0.05). Using ANCOVA to adjust for the non-significant (p = 0.141) baseline difference between groups, the previously injured group demonstrated a greater response to warm-up and static stretching, however this was not statistically significant (p = 0.05). Warm-up significantly increased hamstring flexibility. Static stretching also increased hamstring flexibility, whereas dynamic did not, in agreement with previous findings on uninjured controls. The effect of warm-up and static stretching on flexibility was greater in those with reduced flexibility post-injury, but this did not reach statistical significance. Further prospective research is required to validate the hypothesis that increased flexibility improves outcomes. ACTRN12608000638336.

  6. Stretching human mesenchymal stromal cells on stiffness-customized collagen type I generates a smooth muscle marker profile without growth factor addition

    Science.gov (United States)

    Rothdiener, Miriam; Hegemann, Miriam; Uynuk-Ool, Tatiana; Walters, Brandan; Papugy, Piruntha; Nguyen, Phong; Claus, Valentin; Seeger, Tanja; Stoeckle, Ulrich; Boehme, Karen A.; Aicher, Wilhelm K.; Stegemann, Jan P.; Hart, Melanie L.; Kurz, Bodo; Klein, Gerd; Rolauffs, Bernd

    2016-10-01

    Using matrix elasticity and cyclic stretch have been investigated for inducing mesenchymal stromal cell (MSC) differentiation towards the smooth muscle cell (SMC) lineage but not in combination. We hypothesized that combining lineage-specific stiffness with cyclic stretch would result in a significantly increased expression of SMC markers, compared to non-stretched controls. First, we generated dense collagen type I sheets by mechanically compressing collagen hydrogels. Atomic force microscopy revealed a nanoscale stiffness range known to support myogenic differentiation. Further characterization revealed viscoelasticity and stable biomechanical properties under cyclic stretch with >99% viable adherent human MSC. MSCs on collagen sheets demonstrated a significantly increased mRNA but not protein expression of SMC markers, compared to on culture flasks. However, cyclic stretch of MSCs on collagen sheets significantly increased both mRNA and protein expression of α-smooth muscle actin, transgelin, and calponin versus plastic and non-stretched sheets. Thus, lineage-specific stiffness and cyclic stretch can be applied together for inducing MSC differentiation towards SMCs without the addition of recombinant growth factors or other soluble factors. This represents a novel stimulation method for modulating the phenotype of MSCs towards SMCs that could easily be incorporated into currently available methodologies to obtain a more targeted control of MSC phenotype.

  7. Force transmission in epithelial tissues.

    Science.gov (United States)

    Vasquez, Claudia G; Martin, Adam C

    2016-03-01

    In epithelial tissues, cells constantly generate and transmit forces between each other. Forces generated by the actomyosin cytoskeleton regulate tissue shape and structure and also provide signals that influence cells' decisions to divide, die, or differentiate. Forces are transmitted across epithelia because cells are mechanically linked through junctional complexes, and forces can propagate through the cell cytoplasm. Here, we review some of the molecular mechanisms responsible for force generation, with a specific focus on the actomyosin cortex and adherens junctions. We then discuss evidence for how these mechanisms promote cell shape changes and force transmission in tissues. © 2016 Wiley Periodicals, Inc.

  8. Stretch reflex regulation in healthy subjects and patients with spasticity

    DEFF Research Database (Denmark)

    Nielsen, Jens Bo; Petersen, Nicolas; Crone, Clarissa

    2005-01-01

    In recent years, part of the muscle resistance in spastic patients has been explained by changes in the elastic properties of muscles. However, the adaptive spinal mechanisms responsible for the exaggeration of stretch reflex activity also contribute to muscle stiffness. The available data suggest...... of the spastic symptoms. A recent finding also shows no sign of exaggerated stretch reflexes in muscles voluntarily activated by the spastic patient in general. This is easily explained by the control of stretch reflex activity in healthy subjects. In healthy subjects, the stretch reflex activity is increased...... movements, antagonist muscles should remain silent and maximally relaxed. This is ensured by increasing transmission in several spinal inhibitory pathways. In spastic patients, this control is inadequate, and therefore stretch reflexes in antagonist muscles are easily evoked at the beginning of voluntary...

  9. Bruxism: Is There an Indication for Muscle-Stretching Exercises?

    Science.gov (United States)

    Gouw, Simone; de Wijer, Anton; Creugers, Nico Hj; Kalaykova, Stanimira I

    Bruxism is a common phenomenon involving repetitive activation of the masticatory muscles. Muscle-stretching exercises are a recommended part of several international guidelines for musculoskeletal disorders and may be effective in management of the jaw muscle activity that gives rise to bruxism. However, most studies of muscle-stretching exercises have mainly focused on their influence on performance (eg, range of motion, coordination, and muscle strength) of the limb or trunk muscles of healthy individuals or individuals with sports-related injuries. Very few have investigated stretching of the human masticatory muscles and none muscle-stretching exercises in the management of (sleep) bruxism. This article reviews the literature on muscle-stretching exercises and their potential role in the management of sleep bruxism or its consequences in the musculoskeletal system.

  10. Acute effect of different stretching methods on isometric muscle strength

    Directory of Open Access Journals (Sweden)

    Gabriel Vasconcellos de Lima Costa e Silva

    2014-03-01

    This study investigated the acute effect of static stretching methods (SS and proprioceptive neuromuscular facilitation (PNF on the static muscle strength (SMS. Eleven young male subjects with strength training experience, performed 3 tests with a 48h interval between them, randomly selected, where each one subject carried out all procedures: a hand grip without stretching; b hand grip preceded by static stretching of wrist flexors muscles; c hand grip preceded by PNF stretching of wrist flexors muscles. The Shapiro-Wilk test verified the normality of data, and a one-way ANOVA with repeated measures, followed by Tukey’s post hoc test, evaluated the differences between the groups. The significance was set at p 0.05. In conclusion, both stretching methods had caused negative effects on isometric strength, reducing its levels.

  11. Linear and nonlinear buckling analysis of a locally stretched plate

    Energy Technology Data Exchange (ETDEWEB)

    Kilardj, Madina; Ikhenzzen, Ghania [University of Sciences and Technology Houari Boumediene (U.S.T.H.B), Bab Ezzouar, Algiers (Algeria); Merssager, Tanguy; Kanit, Toufik [Laboratoire de Mecanique de Lille Universite Lille 1, Cite ScientifiqueVilleneuve d' Ascq cedex (France)

    2016-08-15

    Uniformly stretched thin plates do not buckle unless they are in special boundary conditions. However, buckling commonly occurs around discontinuities, such as cracks, cuts, narrow slits, holes, and different openings, of such plates. This study aims to show that buckling can also occur in thin plates that contain no defect or singularity when the stretching is local. This specific stability problem is analyzed with the finite element method. A brief literature review on stretched plates is presented. Linear and nonlinear buckling stress analyses are conducted for a partially stretched rectangular plate, and various load cases are considered to investigate the influence of the partial loading expanse on the critical tensile buckling load. Results are summarized in iso-stress areas, tables and graphs. Local stretching on one end of the plate induces buckling in the thin plate even without geometrical imperfection.

  12. Varying Constants, Gravitation and Cosmology.

    Science.gov (United States)

    Uzan, Jean-Philippe

    2011-01-01

    Fundamental constants are a cornerstone of our physical laws. Any constant varying in space and/or time would reflect the existence of an almost massless field that couples to matter. This will induce a violation of the universality of free fall. Thus, it is of utmost importance for our understanding of gravity and of the domain of validity of general relativity to test for their constancy. We detail the relations between the constants, the tests of the local position invariance and of the universality of free fall. We then review the main experimental and observational constraints that have been obtained from atomic clocks, the Oklo phenomenon, solar system observations, meteorite dating, quasar absorption spectra, stellar physics, pulsar timing, the cosmic microwave background and big bang nucleosynthesis. At each step we describe the basics of each system, its dependence with respect to the constants, the known systematic effects and the most recent constraints that have been obtained. We then describe the main theoretical frameworks in which the low-energy constants may actually be varying and we focus on the unification mechanisms and the relations between the variation of different constants. To finish, we discuss the more speculative possibility of understanding their numerical values and the apparent fine-tuning that they confront us with.

  13. Varying Constants, Gravitation and Cosmology

    Directory of Open Access Journals (Sweden)

    Jean-Philippe Uzan

    2011-03-01

    Full Text Available Fundamental constants are a cornerstone of our physical laws. Any constant varying in space and/or time would reflect the existence of an almost massless field that couples to matter. This will induce a violation of the universality of free fall. Thus, it is of utmost importance for our understanding of gravity and of the domain of validity of general relativity to test for their constancy. We detail the relations between the constants, the tests of the local position invariance and of the universality of free fall. We then review the main experimental and observational constraints that have been obtained from atomic clocks, the Oklo phenomenon, solar system observations, meteorite dating, quasar absorption spectra, stellar physics, pulsar timing, the cosmic microwave background and big bang nucleosynthesis. At each step we describe the basics of each system, its dependence with respect to the constants, the known systematic effects and the most recent constraints that have been obtained. We then describe the main theoretical frameworks in which the low-energy constants may actually be varying and we focus on the unification mechanisms and the relations between the variation of different constants. To finish, we discuss the more speculative possibility of understanding their numerical values and the apparent fine-tuning that they confront us with.

  14. Randomized Controlled Trial Comparing Orthosis Augmented by Either Stretching or Stretching and Strengthening for Stage II Tibialis Posterior Tendon Dysfunction.

    Science.gov (United States)

    Houck, Jeff; Neville, Christopher; Tome, Josh; Flemister, Adolph

    2015-09-01

    The value of strengthening and stretching exercises combined with orthosis treatment in a home-based program has not been evaluated. The purpose of this study was to compare the effects of augmenting orthosis treatment with either stretching or a combination of stretching and strengthening in participants with stage II tibialis posterior tendon dysfunction (TPTD). Participants included 39 patients with stage II TPTD who were recruited from a medical center and then randomly assigned to a strengthening or stretching treatment group. Excluding 3 dropouts, there were 19 participants in the strengthening group and 17 in the stretching group. The stretching treatment consisted of a prefabricated orthosis used in conjunction with stretching exercises. The strengthening treatment consisted of a prefabricated orthosis used in conjunction with the stretching and strengthening exercises. The main outcome measures were self-report (ie, Foot Function Index and Short Musculoskeletal Function Assessment) and isometric deep posterior compartment strength. Two-way analysis of variance was used to test for differences between groups at 6 and 12 weeks after starting the exercise programs. Both groups significantly improved in pain and function over the 12-week trial period. The self-report measures showed minimal differences between the treatment groups. There were no differences in isometric deep posterior compartment strength. A moderate-intensity, home-based exercise program was minimally effective in augmenting orthosis wear alone in participants with stage II TPTD. Level I, prospective randomized study. © The Author(s) 2015.

  15. Effects of repeated ankle stretching on calf muscle-tendon and ankle biomechanical properties in stroke survivors.

    Science.gov (United States)

    Gao, Fan; Ren, Yupeng; Roth, Elliot J; Harvey, Richard; Zhang, Li-Qun

    2011-06-01

    The objective of this study was to investigate changes in active and passive biomechanical properties of the calf muscle-tendon unit induced by controlled ankle stretching in stroke survivors. Ten stroke survivors with ankle spasticity/contracture and ten healthy control subjects received intervention of 60-min ankle stretching. Joint biomechanical properties including resistance torque, stiffness and index of hysteresis were evaluated pre- and post-intervention. Achilles tendon length was measured using ultrasonography. The force output of the triceps surae muscles was characterized via the torque-angle relationship, by stimulating the calf muscles at a controlled intensity across different ankle positions. Compared to healthy controls, the ankle position corresponding to the peak torque of the stroke survivors was shifted towards plantar flexion (Pcalf muscles in stroke survivors under matched stimulations (Pmuscle-tendon level, repeated stretching improved calf muscle force output, which might be associated with decreased muscle fascicle stiffness, increased fascicle length and shortening of the Achilles tendon. The study provided evidence of improvement in muscle tendon properties through stretching intervention. Copyright © 2010 Elsevier Ltd. All rights reserved.

  16. The Effect of Thoracic Joint Mobilization and Self-stretching Exercise on Pulmonary Functions of Patients with Chronic Neck Pain.

    Science.gov (United States)

    Hwangbo, Pil-Neo; Hwangbo, Gak; Park, Jungseo; Lee, Sangyong

    2014-11-01

    [Purpose] The objective of this study was to determine the effect of thoracic joint mobilization and self-stretching exercise on the pulmonary functions of patients with chronic neck pain. [Subjects] The present study was performed with 34 patients with chronic neck pain featuring thoracic kyphosis; we divided them into a thoracic joint mobilization group (TJMG, n = 11), self-stretching exercise group (SSEG, n = 11), and thoracic joint mobilization and self-stretching exercise group (TJMSSEG, n = 12). [Methods] Treatments and exercise were conducted three times a week for six weeks in TJMG, SSEG, and TJMSSEG; the subjects' pulmonary functions in terms of forced vital capacity (FVC), forced expiratory volume at one second (FEV1), and peak expiratory flow (PEF) were measured using CardioTouch equipment. [Results] Comparisons of the individuals within each of the TJMG, SSEG, and TJMSSEG showed that all of FVC, FEV1, and PEF increased significantly; Comparisons within each of the showed that FVC, FEV1, and PEF increased significantly. Among the study groups, FVC was significantly higher in TJMSSEG than in TJMG after six weeks; FEV1 was significantly higher in TJMSSEG than in TJMG and SSEG after four and six weeks; and PEF was significantly higher in TJMSSEG than in TJMG and SSEG after six weeks. [Conclusion] The study results indicate that thoracic joint mobilization and self-stretching exercise are effective interventions for increasing FVC, FEV1, and PEF among pulmonary functions.

  17. From the Rydberg constant to the fundamental constants metrology

    International Nuclear Information System (INIS)

    Nez, F.

    2005-06-01

    This document reviews the theoretical and experimental achievements of the author since the beginning of his scientific career. This document is dedicated to the spectroscopy of hydrogen, deuterium and helium atoms. The first part is divided into 6 sub-sections: 1) the principles of hydrogen spectroscopy, 2) the measurement of the 2S-nS/nD transitions, 3) other optical frequency measurements, 4) our contribution to the determination of the Rydberg constant, 5) our current experiment on the 1S-3S transition, 6) the spectroscopy of the muonic hydrogen. Our experiments have improved the accuracy of the Rydberg Constant by a factor 25 in 15 years and we have achieved the first absolute optical frequency measurement of a transition in hydrogen. The second part is dedicated to the measurement of the fine structure constant and the last part deals with helium spectroscopy and the search for optical references in the near infrared range. (A.C.)

  18. Constant fields and constant gradients in open ionic channels.

    Science.gov (United States)

    Chen, D P; Barcilon, V; Eisenberg, R S

    1992-05-01

    Ions enter cells through pores in proteins that are holes in dielectrics. The energy of interaction between ion and charge induced on the dielectric is many kT, and so the dielectric properties of channel and pore are important. We describe ionic movement by (three-dimensional) Nemst-Planck equations (including flux and net charge). Potential is described by Poisson's equation in the pore and Laplace's equation in the channel wall, allowing induced but not permanent charge. Asymptotic expansions are constructed exploiting the long narrow shape of the pore and the relatively high dielectric constant of the pore's contents. The resulting one-dimensional equations can be integrated numerically; they can be analyzed when channels are short or long (compared with the Debye length). Traditional constant field equations are derived if the induced charge is small, e.g., if the channel is short or if the total concentration gradient is zero. A constant gradient of concentration is derived if the channel is long. Plots directly comparable to experiments are given of current vs voltage, reversal potential vs. concentration, and slope conductance vs. concentration. This dielectric theory can easily be tested: its parameters can be determined by traditional constant field measurements. The dielectric theory then predicts current-voltage relations quite different from constant field, usually more linear, when gradients of total concentration are imposed. Numerical analysis shows that the interaction of ion and channel can be described by a mean potential if, but only if, the induced charge is negligible, that is to say, the electric field is spatially constant.

  19. Thermophoretic forces on DNA measured with a single-molecule spring balance

    DEFF Research Database (Denmark)

    Pedersen, Jonas Nyvold; Lüscher, Christopher James; Marie, Rodolphe

    2014-01-01

    of the thermophoretic force in a static configuration finds forces up to 130 fN. This is eleven times stronger than the force experienced by the same molecule in the same thermal gradient in bulk, where the molecule shields itself. Our stronger forces stretch the middle of the molecule up to 80% of its contour length......We stretch a single DNA molecule with thermophoretic forces and measure these forces with a spring balance: the DNA molecule itself. It is an entropic spring which we calibrate, using as a benchmark its Brownian motion in the nanochannel that contains and prestretches it. This direct measurement...

  20. Learning Read-constant Polynomials of Constant Degree modulo Composites

    DEFF Research Database (Denmark)

    Chattopadhyay, Arkadev; Gavaldá, Richard; Hansen, Kristoffer Arnsfelt

    2011-01-01

    Boolean functions that have constant degree polynomial representation over a fixed finite ring form a natural and strict subclass of the complexity class \\textACC0ACC0. They are also precisely the functions computable efficiently by programs over fixed and finite nilpotent groups. This class...... is not known to be learnable in any reasonable learning model. In this paper, we provide a deterministic polynomial time algorithm for learning Boolean functions represented by polynomials of constant degree over arbitrary finite rings from membership queries, with the additional constraint that each variable...

  1. Theoretical modelling of physiologically stretched vessel in magnetisable stent assisted magnetic drug targeting application

    International Nuclear Information System (INIS)

    Mardinoglu, Adil; Cregg, P.J.; Murphy, Kieran; Curtin, Maurice; Prina-Mello, Adriele

    2011-01-01

    The magnetisable stent assisted magnetic targeted drug delivery system in a physiologically stretched vessel is considered theoretically. The changes in the mechanical behaviour of the vessel are analysed under the influence of mechanical forces generated by blood pressure. In this 2D mathematical model a ferromagnetic, coiled wire stent is implanted to aid collection of magnetic drug carrier particles in an elastic tube, which has similar mechanical properties to the blood vessel. A cyclic mechanical force is applied to the elastic tube to mimic the mechanical stress and strain of both the stent and vessel while in the body due to pulsatile blood circulation. The magnetic dipole-dipole and hydrodynamic interactions for multiple particles are included and agglomeration of particles is also modelled. The resulting collection efficiency of the mathematical model shows that the system performance can decrease by as much as 10% due to the effects of the pulsatile blood circulation. - Research highlights: →Theoretical modelling of magnetic drug targeting on a physiologically stretched stent-vessel system. →Cyclic mechanical force applied to mimic the mechanical stress and strain of both stent and vessel. →The magnetic dipole-dipole and hydrodynamic interactions for multiple particles is modelled. →Collection efficiency of the mathematical model is calculated for different physiological blood flow and magnetic field strength.

  2. Linear viscoelastic characterization from filament stretching rheometry

    DEFF Research Database (Denmark)

    Wingstrand, Sara Lindeblad; Alvarez, Nicolas J.; Hassager, Ole

    Traditionally, linear viscoelasticity is measured using small amplitude oscillatory shear flow. Due to experimental difficulties, shear flows are predominately confined to the linear and mildly nonlinear regime. On the other hand, extensional flows have proven more practical in measuring viscoela......Traditionally, linear viscoelasticity is measured using small amplitude oscillatory shear flow. Due to experimental difficulties, shear flows are predominately confined to the linear and mildly nonlinear regime. On the other hand, extensional flows have proven more practical in measuring...... viscoelasticity well into the nonlinear regime. Therefore at present, complete rheological characterization of a material requires two apparatuses: a shear and an extensional rheometer. This work is focused on developing a linear viscoelastic protocol for the filament stretching rheometer (FSR) in order...... to measure both linear and nonlinear dynamics on a single apparatus. With a software modification to the FSR motor control, we show that linear viscoelasticity can be measured via small amplitude squeeze flow (SASF). Squeeze flow is a combination of both shear and extensional flow applied by axially...

  3. Effects of ionic strength on force transients induced by flash photolysis of caged ATP in covalently crosslinked rabbit psoas muscle fibers.

    Science.gov (United States)

    Yamada, K; Emoto, Y; Horiuti, K; Tawada, K

    1993-01-01

    Single fibers from glycerinated rabbit psoas muscle were treated with 1-ethyl-3[3-(dimethylamino) propyl] carbodiimide (EDC), after rigor was induced, to crosslink myosin heads to actin. The optimally pre-stretched (approximately 1.8%), partially crosslinked fibers produce a large force when MgATP is depleted, and this force is abolished when MgATP is reintroduced, even in high ionic strength solution of 0.5 M (Tawada et al. 1989). We investigated the rate of force decay in the crosslinked, force-producing fibers using pulse photolysis of caged ATP (Goldman et al. 1984). The decay of force was fast, the rate of which depending both on the ionic strength and on the amount of ATP released (0.2-2.2 mM) with the second-order rate constant of 0.5-1 x 10(5) M-1s-1 at the ionic strength of 0.5 M. At high ionic strength (1-2M) force decayed at lower rate. At low ionic strength (0.1-0.2 M), however, force decayed more rapidly, but force redeveloped subsequently, which is probably caused by uncrosslinked myosin heads.

  4. Does weightlifting increase residual force enhancement?

    Science.gov (United States)

    Siebert, Tobias; Kurch, David; Blickhan, Reinhard; Stutzig, Norman

    2016-07-05

    The force maintained following stretching of an active muscle exceeds the isometric force at the same muscle length. This residual force enhancement (RFE) is different for various muscles. It is currently unknown whether training induces changes in RFE. Weightlifters perform a large number of eccentric contractions during training, and RFE might be functionally relevant. The aim of this study was to examine whether there is increased RFE in weightlifters versus a reference group. Therefore, we measured external reaction forces during a multi-joint leg extension in weightlifters (n=10) and a reference group (n=11) using a motor driven leg press dynamometer (ISOMED 2000). Steady state isometric forces after stretching were compared to the corresponding forces obtained during isometric reference contractions. Statistical analyses yielded a significant RFE for both groups (pweightlifting group versus the reference group. We conclude that long-term weightlifting has only a minor influence on RFE. We speculate that the specific training including a combination of eccentric and concentric exercises induced almost no changes in titin-isoform expression which may be responsible for generation of RFE after active muscle stretching. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. STRETCH FABRICS IN LEATHER MANUFACTURING: PERFORMANCE PROPERTIES OF STRECH LEATHERS

    Directory of Open Access Journals (Sweden)

    ORK Nilay

    2016-05-01

    Full Text Available Product variability of manufactured leather goods such as garment leathers could be closely related to the wear comfort because each material forming the garments are affected the comfort properties of the products. Considering the significant demand to elastic woven stretch fabrics and the advantages provided to leather goods like allowing easy body movements, well-fitting and keeping the shape make the use of stretch fabrics focus in interest. In this study, the performance properties of stretch leathers, leathers and spandex fabrics were presented and the differences between the characteristic properties of the leathers were described. For this purpose, physical characteristics of leathers were investigated in terms of thickness, weight, drape ability, stiffness, bending stiffness, air and water vapor permeability. The drape ability, stiffness and bending stiffness properties were significantly affected by the stretch fabrics laminated on the suede side of the leathers. The drape ability, stiffness and bending values were increased due to the implementation of stretch fabrics. There was no significant difference between the air permeability values of the leathers prior and after the implementation of stretch fabrics in contrast to water vapor permeability. The results of this study showed that the aesthetic behavior of clothing materials such as drape and stiffness properties as well as water vapor permeability was mainly affected from the implementation of the stretch fabrics.

  6. From the Rydberg constant to the fundamental constants metrology; De la constante de Rydberg a la metrologie des constantes fondamentales

    Energy Technology Data Exchange (ETDEWEB)

    Nez, F

    2005-06-15

    This document reviews the theoretical and experimental achievements of the author since the beginning of his scientific career. This document is dedicated to the spectroscopy of hydrogen, deuterium and helium atoms. The first part is divided into 6 sub-sections: 1) the principles of hydrogen spectroscopy, 2) the measurement of the 2S-nS/nD transitions, 3) other optical frequency measurements, 4) our contribution to the determination of the Rydberg constant, 5) our current experiment on the 1S-3S transition, 6) the spectroscopy of the muonic hydrogen. Our experiments have improved the accuracy of the Rydberg Constant by a factor 25 in 15 years and we have achieved the first absolute optical frequency measurement of a transition in hydrogen. The second part is dedicated to the measurement of the fine structure constant and the last part deals with helium spectroscopy and the search for optical references in the near infrared range. (A.C.)

  7. Systematics of constant roll inflation

    Science.gov (United States)

    Anguelova, Lilia; Suranyi, Peter; Wijewardhana, L. C. R.

    2018-02-01

    We study constant roll inflation systematically. This is a regime, in which the slow roll approximation can be violated. It has long been thought that this approximation is necessary for agreement with observations. However, recently it was understood that there can be inflationary models with a constant, and not necessarily small, rate of roll that are both stable and compatible with the observational constraint ns ≈ 1. We investigate systematically the condition for such a constant-roll regime. In the process, we find a whole new class of inflationary models, in addition to the known solutions. We show that the new models are stable under scalar perturbations. Finally, we find a part of their parameter space, in which they produce a nearly scale-invariant scalar power spectrum, as needed for observational viability.

  8. Determination of the constants of the solubility product of Ln(OH){sub 3} and the effect of the chloride ions on the lanthanum hydrolysis, praseodymium and lutetium in aqueous solutions of ion force 2 Molar; Determinacion de las constantes del producto de solubilidad de Ln(OH){sub 3} y el efecto de los iones cloruro sobre la hidrolisis de lantano, praseodimio y lutecio en soluciones acuosas de fuerza ionica 2 Molar

    Energy Technology Data Exchange (ETDEWEB)

    Lopez G, H.D

    2005-07-01

    The behavior of lanthanum (III), praseodymium (III), and lutetium (III) was studied in 2 M NaClO{sub 4} (aq) and 2 M NaCl (aq) at 303 K and free -CO{sub 2} conditions. Solubility diagrams (p Ln(aq)-pC{sub H}) were obtained by means of a radiochemical method. The pC{sub H} borderlines of saturation and unsaturation zones of the solutions and solubility product constants for Ln(OH){sub 3} were determined from these diagrams. The fitting of the solubility equation to the experimental values of p Ln(aq)-pC{sub H} diagrams allowed the calculation of the first hydrolysis and solubility product constants. Independently, the stability constants for the first species of hydrolysis were determined by means of pH titrations, the data were treated with the program SUPERQUAD and fitted to the mean ligand number equation. The stability constants for the species LnCl{sup 2+} were as well calculated in 2M ionic strength and 303 K from the hydrolysis constant values obtained in both perchlorate and chloride media. The values obtained for La, Pr and Lu were: logK{sub ps}: 21.11 {+-} 0.09, 19.81 {+-} 0.11 and 18.10 {+-} 0.13 in 2M NaClO{sub 4}; logK{sub ps}: 22.22 {+-} 0.09, 21.45 {+-} 0.14 and 18.52 {+-} 0.29 in 2M NaCl; log {beta}{sub 1}: - 8.64 {+-} 0.02, - 8.37 {+-} 0.01 and - 7.95 {+-} 0.11 in 2M NaClO{sub 4}; log {beta}{sub 1}{sup /} : - 9.02 {+-} 0.11, - 8.75 {+-} 0.01 and - 8.12 {+-} 0.03 in 2M NaCl and the values for log {beta}{sub 1,Cl} were - 0.0255, - 0.155 and - 0.758, respectively. (Author)

  9. Strain fluctuations and elastic constants

    Energy Technology Data Exchange (ETDEWEB)

    Parrinello, M.; Rahman, A.

    1982-03-01

    It is shown that the elastic strain fluctuations are a direct measure of elastic compliances in a general anisotropic medium; depending on the ensemble in which the fluctuation is measured either the isothermal or the adiabatic compliances are obtained. These fluctuations can now be calculated in a constant enthalpy and pressure, and hence, constant entropy, ensemble due to recent develpments in the molecular dynamics techniques. A calculation for a Ni single crystal under uniform uniaxial 100 tensile or compressive load is presented as an illustration of the relationships derived between various strain fluctuations and the elastic modulii. The Born stability criteria and the behavior of strain fluctuations are shown to be related.

  10. due to Capillary Forces

    Directory of Open Access Journals (Sweden)

    Hassen M. Ouakad

    2009-01-01

    Full Text Available We present modeling and analysis for the static behavior and collapse instabilities of doubly-clamped and cantilever microbeams subjected to capillary forces. These forces can be as a result of a volume of liquid trapped underneath the microbeam during the rinsing and drying process in fabrication. The model considers the microbeam as a continuous medium, the capillary force as a nonlinear function of displacement, and accounts for the mid-plane stretching and geometric nonlinearities. The capillary force is assumed to be distributed over a specific length underneath the microbeam. The Galerkin procedure is used to derive a reduced-order model consisting of a set of nonlinear algebraic and differential equations that describe the microbeams static and dynamic behaviors. We study the collapse instability, which brings the microbeam from its unstuck configuration to touch the substrate and gets stuck in the so-called pinned configuration. We calculate the pull-in length that distinguishes the free from the pinned configurations as a function of the beam thickness and gap width for both microbeams. Comparisons are made with analytical results reported in the literature based on the Ritz method for linear and nonlinear beam models. The instability problem, which brings the microbeam from a pinned to adhered configuration is also investigated. For this case, we use a shooting technique to solve the boundary-value problem governing the deflection of the microbeams. The critical microbeam length for this second instability is also calculated.

  11. An investigation into UV light exposure as an experimental model for artificial aging on tensile strength and force delivery of elastomeric chain.

    Science.gov (United States)

    Wahab, Siti Waznah; Bister, Dirk; Sherriff, Martyn

    2014-02-01

    This study investigated the effect of ultraviolet type A light (UVA) exposure on the tensile properties of elastomeric chain. UVA light exposure was used as model for artificial aging, simulating prolonged storage of elastomeric chain. Tensile strength (n = 60) was measured after exposing Ormco, Forestadent and 3M chains to UVA light for 0, 2, 3, and 4 weeks. Force decay was measured (n = 60) using chain exposed for 5, 10, and 14 days. The chains were subsequently stretched at a constant distance and the resulting forces measured at 0, 1, 24 hours and 7, 14, 21, and 28 days. This test simulated a clinical scenario of pre-stretching and subsequent shortening of elastomeric chain. Tensile strength had statistically significant difference and was directly related to the duration of ultraviolet (UV) light exposure. Forestadent chain, which had the second highest value for the 'as received' product, showed the most consistent values over time with the lowest degradation. Ormco showed the lowest values for 'as received' as well as after UV exposure; 3M chain had the highest loss of tensile strength. Force decay was also significantly different. UV light exposure of 10 days or more appears to mark a 'watershed' between products: 3M had most survivors, Forestadent chain had some survivors, depending on the time the chain was stretched for. None of the Ormco product survived UV light exposure for more than 5 days. UVA light exposure may be used as a model for artificial aging as it reduces force delivery and tensile strength of exposed chains.

  12. AI-augmented time stretch microscopy

    Science.gov (United States)

    Mahjoubfar, Ata; Chen, Claire L.; Lin, Jiahao; Jalali, Bahram

    2017-02-01

    Cell reagents used in biomedical analysis often change behavior of the cells that they are attached to, inhibiting their native signaling. On the other hand, label-free cell analysis techniques have long been viewed as challenging either due to insufficient accuracy by limited features, or because of low throughput as a sacrifice of improved precision. We present a recently developed artificial-intelligence augmented microscope, which builds upon high-throughput time stretch quantitative phase imaging (TS-QPI) and deep learning to perform label-free cell classification with record high-accuracy. Our system captures quantitative optical phase and intensity images simultaneously by frequency multiplexing, extracts multiple biophysical features of the individual cells from these images fused, and feeds these features into a supervised machine learning model for classification. The enhanced performance of our system compared to other label-free assays is demonstrated by classification of white blood T-cells versus colon cancer cells and lipid accumulating algal strains for biofuel production, which is as much as five-fold reduction in inaccuracy. This system obtains the accuracy required in practical applications such as personalized drug development, while the cells remain intact and the throughput is not sacrificed. Here, we introduce a data acquisition scheme based on quadrature phase demodulation that enables interruptionless storage of TS-QPI cell images. Our proof of principle demonstration is capable of saving 40 TB of cell images in about four hours, i.e. pictures of every single cell in 10 mL of a sample.

  13. Adhesive forces at bimetallic interfaces

    International Nuclear Information System (INIS)

    Das, M.P.; Nafari, N.; Ziesche, P.; Kaschner, H.R.

    1987-03-01

    Force concepts in condensed systems have progressed significantly in recent years. In the context of bimetallic interfaces we consider the Pauli-Hellman-Feynman theorem, use it to check the variational calculations of interfacial energies and estimate the force constants. (author). 13 refs, 2 figs, 2 tabs

  14. Force optimized recoil control system

    Science.gov (United States)

    Townsend, P. E.; Radkiewicz, R. J.; Gartner, R. F.

    1982-05-01

    Reduction of the recoil force of high rate of fire automatic guns was proven effective. This system will allow consideration of more powerful guns for use in both helicopter and armored personnel carrier applications. By substituting the large shock loads of firing guns with a nearly constant force, both vibration and fatigue problems that prevent mounting of powerful automatic guns is eliminated.

  15. Elastic constants of diamond from molecular dynamics simulations

    International Nuclear Information System (INIS)

    Gao Guangtu; Van Workum, Kevin; Schall, J David; Harrison, Judith A

    2006-01-01

    The elastic constants of diamond between 100 and 1100 K have been calculated for the first time using molecular dynamics and the second-generation, reactive empirical bond-order potential (REBO). This version of the REBO potential was used because it was redesigned to be able to model the elastic properties of diamond and graphite at 0 K while maintaining its original capabilities. The independent elastic constants of diamond, C 11 , C 12 , and C 44 , and the bulk modulus were all calculated as a function of temperature, and the results from the three different methods are in excellent agreement. By extrapolating the elastic constant data to 0 K, it is clear that the values obtained here agree with the previously calculated 0 K elastic constants. Because the second-generation REBO potential was fit to obtain better solid-state force constants for diamond and graphite, the agreement with the 0 K elastic constants is not surprising. In addition, the functional form of the second-generation REBO potential is able to qualitatively model the functional dependence of the elastic constants and bulk modulus of diamond at non-zero temperatures. In contrast, reactive potentials based on other functional forms do not reproduce the correct temperature dependence of the elastic constants. The second-generation REBO potential also correctly predicts that diamond has a negative Cauchy pressure in the temperature range examined

  16. Non-constant retardation coefficient

    International Nuclear Information System (INIS)

    Wang Zhiming; Gu Zhijie; Yang Yue'e; Li Shushen

    2004-12-01

    Retardation coefficient is one of the important parameters used in transport models describing radionuclide migration in geological media and usually regarded as a constant in the models. The objectives of the work are to understand: (1) Whether the retardation coefficient, R d , is a constant? (2) How much effect is R d on calculated consequence if R d is not constant? (3) Is the retardation coefficient derived from distribution coefficient, k d , according to conventional equation suitable for safety assessment? The objectives are achieved through test and analysis of the test results on radionuclide migration in unsaturated loess. It can be seen from the results that retardation coefficient, R d , of 85 Sr is not constant and increases with water content, θ, under unsaturated condition. R d , of 85 Sr derived from k d according to conventional equation can not be used for safety assessment. R d , used for safety assessment should be directly measured, rather than derived from k d . It is shown from calculation that the effect of R d on calculated consequence is very considerable. (authors)

  17. Universal relation between spectroscopic constants

    Indian Academy of Sciences (India)

    (3) The author has used eq. (6) of his paper to calculate De. This relation leads to a large deviation from the correct value depending upon the extent to which experimental values are known. Guided by this fact, in our work, we used experimentally observed De values to derive the relation between spectroscopic constants.

  18. Buckling patterns in biaxially pre-stretched bilayer shells: wrinkles, creases, folds and fracture-like ridges.

    Science.gov (United States)

    Al-Rashed, Rashed; López Jiménez, Francisco; Marthelot, Joel; Reis, Pedro M

    2017-11-08

    We introduce a new experimental system to study the effects of pre-stretch on the buckling patterns that emerge from the biaxial compression of elastomeric bilayer shells. Upon fabrication of the samples, releasing the pre-stretch in the substrate through deflation places the outer film in a state of biaxial compression and yields a variety of buckling patterns. We systematically explore the parameter space by varying the pre-stretch of the substrate and the ratio between the stiffness of the substrate and film. The phase diagram of the system exhibits a variety of buckling patterns: from the classic periodic wrinkle to creases, folds, and high aspect ratio ridges. Our system is capable of readily transitioning between these buckling patterns, a first for biaxial systems. We focus on the wrinkle to ridge transition. In the latter, we find that pre-stretch plays an essential role and that the ridge geometry (width, height) remains nearly constant throughout their formation process. For the localized ridged patterns, we find that the propagation of the ridge tip depends strongly on both strain and stiffness ratio, in a way that is akin to hierarchical fracture.

  19. Stabilized power constant alimentation; Alimentation regulee a puissance constante

    Energy Technology Data Exchange (ETDEWEB)

    Roussel, L. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-06-01

    The study and realization of a stabilized power alimentation variable from 5 to 100 watts are described. In order to realize a constant power drift of Lithium compensated diodes, we have searched a 1 per cent precision of regulation and a response time minus than 1 sec. Recent components like Hall multiplicator and integrated amplifiers give this possibility and it is easy to use permutable circuits. (author) [French] On decrit l'etude et la realisation d'une alimentation a puissance constante reglable dans une gamme de 5 a 100 watts. Prevue pour le drift a puissance constante des diodes compensees au lithium, l'etude a ete menee en vue d'obtenir une precision de regulation de 1 pour cent et un temps de reponse inferieur a la seconde. Des systemes recents tels que multiplicateurs a effet Hall et circuits integres ont permis d'atteindre ce but tout en facilitant l'emploi de modules interchangeables. (auteur)

  20. Constant-bandwidth constant-temperature hot-wire anemometer.

    Science.gov (United States)

    Ligeza, P

    2007-07-01

    A constant-temperature anemometer (CTA) enables the measurement of fast-changing velocity fluctuations. In the classical solution of CTA, the transmission band is a function of flow velocity. This is a minor drawback when the mean flow velocity does not significantly change, though it might lead to dynamic errors when flow velocity varies over a considerable range. A modification is outlined, whereby an adaptive controller is incorporated in the CTA system such that the anemometer's transmission band remains constant in the function of flow velocity. For that purpose, a second feedback loop is provided, and the output signal from the anemometer will regulate the controller's parameters such that the transmission bandwidth remains constant. The mathematical model of a CTA that has been developed and model testing data allow a through evaluation of the proposed solution. A modified anemometer can be used in measurements of high-frequency variable flows in a wide range of velocities. The proposed modification allows the minimization of dynamic measurement errors.

  1. Effects of Static Stretching and Playing Soccer on Knee Laxity

    NARCIS (Netherlands)

    Baumgart, Christian; Gokeler, Alli; Donath, Lars; Hoppe, Matthias W.; Freiwald, Juergen

    2015-01-01

    Objective: This study investigated exercise-induced effects of static stretching and playing soccer on anterior tibial translation (ATT) of the knee joint. Design: Randomized controlled trial. Setting: University biomechanics laboratory. Participants: Thirty-one athletes were randomly assigned into

  2. Automated force controller for amplitude modulation atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Miyagi, Atsushi, E-mail: atsushi.miyagi@inserm.fr, E-mail: simon.scheuring@inserm.fr; Scheuring, Simon, E-mail: atsushi.miyagi@inserm.fr, E-mail: simon.scheuring@inserm.fr [U1006 INSERM, Université Aix-Marseille, Parc Scientifique et Technologique de Luminy, 163 Avenue de Luminy, 13009 Marseille (France)

    2016-05-15

    Atomic Force Microscopy (AFM) is widely used in physics, chemistry, and biology to analyze the topography of a sample at nanometer resolution. Controlling precisely the force applied by the AFM tip to the sample is a prerequisite for faithful and reproducible imaging. In amplitude modulation (oscillating) mode AFM, the applied force depends on the free and the setpoint amplitudes of the cantilever oscillation. Therefore, for keeping the applied force constant, not only the setpoint amplitude but also the free amplitude must be kept constant. While the AFM user defines the setpoint amplitude, the free amplitude is typically subject to uncontrollable drift, and hence, unfortunately, the real applied force is permanently drifting during an experiment. This is particularly harmful in biological sciences where increased force destroys the soft biological matter. Here, we have developed a strategy and an electronic circuit that analyzes permanently the free amplitude of oscillation and readjusts the excitation to maintain the free amplitude constant. As a consequence, the real applied force is permanently and automatically controlled with picoNewton precision. With this circuit associated to a high-speed AFM, we illustrate the power of the development through imaging over long-duration and at various forces. The development is applicable for all AFMs and will widen the applicability of AFM to a larger range of samples and to a larger range of (non-specialist) users. Furthermore, from controlled force imaging experiments, the interaction strength between biomolecules can be analyzed.

  3. EFFECT OF STATIC STRETCHING ON STRENGTH OF HAMSTRING MUSCLE

    Directory of Open Access Journals (Sweden)

    Shweta P Pachpute

    2016-04-01

    Full Text Available Background: Flexibility is an indisputable component of fitness defined as the ability to move a single joint or series of joints through an unrestricted pain free range of motion. Static stretching consists of stretching a muscle or group of muscle to its farthest point and then maintaining or holding that position. The literature supports that muscles are capable of exerting their greatest strength when they are fully lengthen. Hence this study was conducted to find the effect of static stretching on hamstring muscle. Methods: The study was experimental study design. 40 samples were selected by purposive sampling method. Flexibility of the hamstring muscle unilaterally right side (arbitrarily chosen was measured by active knee extension test of all the subjects who met the inclusion criteria of the study. After measuring the flexibility of hamstring muscle, strength was measured by 1RM for the same side (right hamstring muscle. Static Stretching Protocol was given for 5 days per week for 6 weeks to all the participants. After the 6 weeks of training, knee extension deficiency and 1RM was documented. Result: Statistical analysis using Paired t-test was done. The t-test showed that there was significant effect of static stretching on 1RM of hamstring muscle (p<0.05 & active knee extension test (p=0.000. Conclusion: Static stretching showed significant change in pre and post 1RM of hamstring muscle and active knee extension test. There was significant improvement of hamstring muscles flexibility and strength after giving static stretching in female population. So it is possible that females who are unable to participate in traditional strength training activities may be able to experience gains through static stretching.

  4. Effects of right atrial stretch on plasma renin activity.

    Science.gov (United States)

    Annat, G; Grandjean, B; Vincent, M; Jarsaillon, E; Sassard, J

    1976-04-01

    In anaesthetized dog, right atrial stretch leads in the first five minutes to a decrease in plasma renin activity, when measured in inferior vena cava just above the renal veins. Bilateral cervical vagotomy increases plasma renin activity. After vagotomy, atrial stretch no longer has any effect on plasma renin activity. The results support the hypothesis of a control of renin secretion originating from atrial volume receptors.

  5. Localization and stretch-dependence of lung elastase activity in development and compensatory growth.

    Science.gov (United States)

    Young, Sarah Marie; Liu, Sheng; Joshi, Rashika; Batie, Matthew R; Kofron, Matthew; Guo, Jinbang; Woods, Jason C; Varisco, Brian Michael

    2015-04-01

    Synthesis and remodeling of the lung matrix is necessary for primary and compensatory lung growth. Because cyclic negative force is applied to developing lung tissue during the respiratory cycle, we hypothesized that stretch is a critical regulator of lung matrix remodeling. By using quantitative image analysis of whole-lung and whole-lobe elastin in situ zymography images, we demonstrated that elastase activity increased twofold during the alveolar stage of postnatal lung morphogenesis in the mouse. Remodeling was restricted to alveolar walls and ducts and was nearly absent in dense elastin band structures. In the mouse pneumonectomy model of compensatory lung growth, elastase activity increased threefold, peaking at 14 days postpneumonectomy and was higher in the accessory lobe compared with other lobes. Remodeling during normal development and during compensatory lung growth was different with increased major airway and pulmonary arterial remodeling during development but not regeneration, and with homogenous remodeling throughout the parenchyma during development, but increased remodeling only in subpleural regions during compensatory lung growth. Left lung wax plombage prevented increased lung elastin during compensatory lung growth. To test whether the adult lung retains an innate capacity to remodel elastin, we developed a confocal microscope-compatible stretching device. In ex vivo adult mouse lung sections, lung elastase activity increased exponentially with strain and in peripheral regions of lung more than in central regions. Our study demonstrates that lung elastase activity is stretch-dependent and supports a model in which externally applied forces influence the composition, structure, and function of the matrix during periods of alveolar septation. Copyright © 2015 the American Physiological Society.

  6. Efficacy of hamstring stretching programs in schoolchildren. A systematic review

    Directory of Open Access Journals (Sweden)

    Carlos-Alberto BECERRA FERNANDEZ

    2017-03-01

    Full Text Available The main purpose of the present review was to examine the scientific literature on the effects of physical education-based stretching programs on hamstring extensibility in schoolchildren aged 6-11 years. For this purpose relevant studies were searched from ten electronic databases dated up through May 2015. Of the 25 potentially relevant articles identified and retrieved for more detailed evaluation, only eight studies were included in the present review because they met the inclusion criteria. The overall results showed that incorporating hamstring stretching as a part of physical education classes produces a significant improvement in the scores of the tests: straight leg raise and classic sit-and-reach, for the experimental groups, but not for control groups. Stretching programs can be included in Physical Education classes, specifically during the warm-up and the cool down periods in order to improve hamstring extensibility. Although it seems that the stretching exercises in the warm-up period could be less effective in gaining flexibility in school children. Studies that use a stretching volume between 4 and 7 minutes per session and 2-4 training classes per week, obtain statistically significant improvements on the levels of hamstring flexibility in the experimental groups. However, after a five-week detraining period, children revert back to their initial flexibility levels. Therefore, it seems appropriate that physical education teachers should implement stretching programs to improve the students´ flexibility during the Physical Education classes.

  7. Effects of Stretching Exercise on Heart Rate Variability During Pregnancy.

    Science.gov (United States)

    Logan, Jeongok G; Yeo, SeonAe

    Little evidence exists for effects of low-intensity exercises such as stretching on cardiovascular health in pregnant women. Our aim was to evaluate the effect of a 20-minute stretching exercise on heart rate variability (HRV), blood pressure (BP), and heart rate (HR) in healthy pregnant women. In 15 pregnant women with a mean (SD) age of 29.47 (4.07) years and mean (SD) gestational weeks of 26.53 (8.35), HRV, and BP were measured before and after the 20-minute stretching exercise. Compared with before the stretching exercise, standard deviation of the normal-to-normal intervals, total variability of heart rate, increased by 7.40 milliseconds (t = -2.31, P = .04) and root mean square of successive differences, a surrogate measure of parasympathetic outflow, also increased by 11.68 milliseconds (Z = -2.04, P = .04) after the stretching exercise. Diastolic BP and HR decreased by 2.13 mm Hg (t = 1.93, P = .07) and 3.31 bpm (t = 2.17, P = .05), respectively, but they did not reach statistical significance. These preliminary data suggest that 20 minutes of stretching exercise may promote cardiovascular health by attenuating the loss of parasympathetic tone associated with pregnancy.

  8. [Sciatica. From stretch rack to microdiscectomy].

    Science.gov (United States)

    Gruber, P; Böni, T

    2015-12-01

    In ancient times as well as in the Middle Ages treatment options for discogenic nerve compression syndrome were limited and usually not very specific because of low anatomical and pathophysiological knowledge. The stretch rack (scamnum Hippocratis) was particularly prominent but was widely used as a therapeutic device for very different spinal disorders. Since the beginning of the nineteenth century anatomical knowledge increased and the advances in the fields of asepsis, anesthesia and surgery resulted in an increase in surgical interventions on the spine. In 1908 the first successful lumbar discectomy was initiated and performed by the German neurologist Heinrich O. Oppenheim (1858-1919) and the surgeon Fedor Krause (1857-1937); however, neither recognized the true pathological condition of discogenic nerve compression syndrome. With the landmark report in the New England Journal of Medicine in 1934, the two American surgeons William Jason Mixter (1880-1958) and Joseph Seaton Barr (1901-1963) finally clarified the pathomechanism of lumbar disc herniation and furthermore, propagated discectomy as the standard therapy. Since then interventions on intervertebral discs rapidly increased and the treatment options for lumbar disc surgery quickly evolved. The surgical procedures changed over time and were continuously being refined. In the late 1960s the surgical microscope was introduced for spinal surgery by the work of the famous neurosurgeon Mahmut Gazi Yasargil and his colleague Wolfhard Caspar and so-called microdiscectomy was introduced. Besides open discectomy other interventional techniques were developed to overcome the side effects of surgical procedures. In 1964 the American orthopedic surgeon Lyman Smith (1912-1991) introduced chemonucleolysis, a minimally invasive technique consisting only of a cannula and the proteolytic enzyme chymopapain, which is injected into the disc compartment to dissolve the displaced disc material. In 1975 the Japanese orthopedic

  9. Excitation of skinned muscle fibers by imposed ion gradients. IV. Effects of stretch and perchlorate ion.

    Science.gov (United States)

    Stephenson, E W

    1989-01-01

    Depolarizing ion gradients stimulate 45Ca release in skeletal muscle fibers skinned by microdissection. Several lines of indirect evidence suggest that sealed transverse (T) tubules rather than sarcoplasmic reticulum (SR) are the locus of such stimulatory depolarization. Two implications of this hypothesis were tested. (a) A requirement for signal transmission was evaluated from the stimulation of 45Ca efflux in fibers that had been highly stretched, an intervention that can impair the electrical stimulation of intact fibers. Length was increased over approximately 95-115 s, after loading with 45Ca and rinsing at normal length; prestimulus 45Ca loss due to stretch itself was very small. In the first study, stimulation of 45Ca release by KCl replacement of K propionate was inhibited completely in fibers stretched to twice slack length, compared with fibers at 1.05-1.1 times slack length. Identical protocols did not alter 45Ca release stimulated by caffeine or Mg2+ reduction, implying that SR Ca release per se was fully functional and inhibition was selective for a preceding step in ionic stimulation. In a second study, stimulation by choline Cl replacement of K methanesulfonate, at constant [K+] [Cl-] product, was inhibited strongly; total 45Ca release decreased 69%, and stimulation above control loss decreased 78%, in segments stretched to twice the length at which sarcomere spacing had been 2.2 micron, compared with paired controls from the same fibers kept at 2.3 micron. (b) Perchlorate potentiation of T tubule activation was evaluated in fibers stimulated at constant [K+] [Cl-] at normal length (2.3 micron); this anion shifts the voltage dependence of intramembrane charge movement and contractile activation in intact fibers. Perchlorate (8 mM) potentiated both submaximal stimulation of Ca2+-dependent 45Ca release by partial choline Cl replacement of K methanesulfonate and the small Ca2+-insensitive 45Ca efflux component stimulated by nearly full replacement in

  10. Effects of different dropping intensities on fascicle and tendinous tissue behavior during stretch-shortening cycle exercise.

    Science.gov (United States)

    Ishikawa, Masaki; Komi, Paavo V

    2004-03-01

    This study examined whether the elasticity of the tendinous tissues plays an important role in human locomotion by improving the power output and efficiency of skeletal muscle. Ten subjects performed one-leg drop jumps (DJ) from different dropping heights with a constant rebound height. The fascicle length of the vastus lateralis muscle was measured by using real-time ultrasonography during DJ. In the braking phase of the DJ, fascicle lengthening decreased and the tendinous tissue lengthening increased with increased dropping intensity. In the subsequent push-off phase, the shortening of tendinous tissues increased with higher dropping intensity. The averaged electromyographic activities of the preactivation and braking phases increased and those of the push-off phase decreased as the drop height was increased. With higher dropping height but constant submaximal rebound jump, the stretched tendinous tissue length increased with less stretched fascicle during the braking phase. In the subsequent push-off phase, the recoil of tendinous tissues became greater. These results suggest that the increased prestretch intensity has considerable influence on the process of storage and subsequent recoil of the elastic energy during the stretch-shortening cycle action.

  11. Cosmological Constant and Local Gravity

    CERN Document Server

    Bernabeu, Jose; Mavromatos, Nick E

    2010-01-01

    We discuss the linearization of Einstein equations in the presence of a cosmological constant, by expanding the solution for the metric around a flat Minkowski space-time. We demonstrate that one can find consistent solutions to the linearized set of equations for the metric perturbations, in the Lorentz gauge, which are not spherically symmetric, but they rather exhibit a cylindrical symmetry. We find that the components of the gravitational field satisfying the appropriate Poisson equations have the property of ensuring that a scalar potential can be constructed, in which both contributions, from ordinary matter and $\\Lambda > 0$, are attractive. In addition, there is a novel tensor potential, induced by the pressure density, in which the effect of the cosmological constant is repulsive. We also linearize the Schwarzschild-de Sitter exact solution of Einstein's equations (due to a generalization of Birkhoff's theorem) in the domain between the two horizons. We manage to transform it first to a gauge in whic...

  12. Evolution of the solar constant

    International Nuclear Information System (INIS)

    Newman, M.J.

    1978-01-01

    The ultimate source of the energy utilized by life on Earth is the Sun, and the behavior of the Sun determines to a large extent the conditions under which life originated and continues to thrive. What can be said about the history of the Sun. Has the solar constant, the rate at which energy is received by the Earth from the Sun per unit area per unit time, been constant at its present level since Archean times. Three mechanisms by which it has been suggested that the solar energy output can vary with time are discussed, characterized by long (approx. 10 9 years), intermediate (approx. 10 8 years), and short (approx. years to decades) time scales

  13. Strong Stretching of Poly(ethylene glycol) Brushes Mediated by Ionic Liquid Solvation.

    Science.gov (United States)

    Han, Mengwei; Espinosa-Marzal, Rosa M

    2017-09-07

    We have measured forces between mica surfaces coated with a poly(ethylene glycol) (PEG) brush solvated by a vacuum-dry ionic liquid, 1-ethyl-3-methyl imidazolium bis(trifluoromethylsulfonyl)imide, with a surface forces apparatus. At high grafting density, the solvation mediated by the ionic liquid causes the brush to stretch twice as much as in water. Modeling of the steric repulsion indicates that PEG behaves as a polyelectrolyte; the hydrogen bonding between ethylene glycol and the imidazolium cation seems to effectively charge the polymer brush, which justifies the strong stretching. Importantly, under strong polymer compression, solvation layers are squeezed out at a higher rate than for the neat ionic liquid. We propose that the thermal fluctuations of the PEG chains, larger in the brush than in the mushroom configuration, maintain the fluidity of the ionic liquid under strong compression, in contrast to the solid-like squeezing-out behavior of the neat ionic liquid. This is the first experimental study of the behavior of a polymer brush solvated by an ionic liquid under nanoconfinement.

  14. Photodissociation constant of NO2

    International Nuclear Information System (INIS)

    Nootebos, M.A.; Bange, P.

    1992-01-01

    The velocity of the dissociation of NO 2 into ozone and NO mainly depends on the ultraviolet sunlight quantity, and with that the cloudiness. A correct value for this reaction constant is important for the accurate modelling of O 3 - and NO 2 -concentrations in plumes of electric power plants, in particular in the case of determination of the amount of photochemical summer smog. An advanced signal processing method (deconvolution, correlation) was applied on the measurements. The measurements were carried out from aeroplanes

  15. The effect of warm-up, static stretching and dynamic stretching on hamstring flexibility in previously injured subjects.

    LENUS (Irish Health Repository)

    O'Sullivan, Kieran

    2009-01-01

    BACKGROUND: Warm-up and stretching are suggested to increase hamstring flexibility and reduce the risk of injury. This study examined the short-term effects of warm-up, static stretching and dynamic stretching on hamstring flexibility in individuals with previous hamstring injury and uninjured controls. METHODS: A randomised crossover study design, over 2 separate days. Hamstring flexibility was assessed using passive knee extension range of motion (PKE ROM). 18 previously injured individuals and 18 uninjured controls participated. On both days, four measurements of PKE ROM were recorded: (1) at baseline; (2) after warm-up; (3) after stretch (static or dynamic) and (4) after a 15-minute rest. Participants carried out both static and dynamic stretches, but on different days. Data were analysed using Anova. RESULTS: Across both groups, there was a significant main effect for time (p < 0.001). PKE ROM significantly increased with warm-up (p < 0.001). From warm-up, PKE ROM further increased with static stretching (p = 0.04) but significantly decreased after dynamic stretching (p = 0.013). The increased flexibility after warm-up and static stretching reduced significantly (p < 0.001) after 15 minutes of rest, but remained significantly greater than at baseline (p < 0.001). Between groups, there was no main effect for group (p = 0.462), with no difference in mean PKE ROM values at any individual stage of the protocol (p > 0.05). Using ANCOVA to adjust for the non-significant (p = 0.141) baseline difference between groups, the previously injured group demonstrated a greater response to warm-up and static stretching, however this was not statistically significant (p = 0.05). CONCLUSION: Warm-up significantly increased hamstring flexibility. Static stretching also increased hamstring flexibility, whereas dynamic did not, in agreement with previous findings on uninjured controls. The effect of warm-up and static stretching on flexibility was greater in those with reduced

  16. Matrix metalloproteinase, tissue inhibitor of metalloproteinase and transforming growth factor-beta 1 in frozen shoulder, and their changes as response to intensive stretching and supervised neglect exercise.

    Science.gov (United States)

    Lubis, Andri Maruli Tua; Lubis, Vita Kurniati

    2013-07-01

    Frozen shoulder is characterized with thickening and contracture of joint capsular. The mechanism of this disorder is not yet clear, however, some proteins have been related to frozen shoulder. This study was to compare the serum levels of proteins related to frozen shoulder, such as matrix metalloproteinase (MMP), tissue inhibitor of metalloproteinase (TIMP) and transforming growth factor-beta (TGF-β) between frozen shoulder and normal subjects; and before and after physical exercise active stretching and gentle thawing in frozen shoulder patients. Serum levels of MMP-1, MMP-2, TIMP-1, TIMP-2, and TGF-β1 was measured from frozen shoulder and normal subjects by using ELISA. Functional assessment of shoulder joint in frozen shoulder patients was based on abbreviated Constant score. Frozen shoulder patients were randomly divided into intensive stretching and supervised neglect groups. Abbreviated Constant score and serum samples of frozen shoulder patients were evaluated at baseline, week-6, and week-12 after exercise, while only baseline serum samples of control were measured. MMP/TIMP ratio was calculated from the total sum of MMP-1 and MMP-2 levels divided by the total sum of TIMP-1 and TIMP-2 levels. Baseline MMP-1 and MMP-2 levels were significantly lower, while TIMP-1, TIMP-2, and TGF-β1 levels were significantly higher in frozen shoulder group than in control. Increased MMPs and decreased TIMPs were significantly greater after intensive stretching than after supervised neglect exercise. Abbreviated Constant score improvement was significantly higher in intensive stretching group than in supervised neglect group. Serum levels of MMP-1, MMP-2, TIMP-1, TIMP-2, and TGF-β1 may be associated to frozen shoulder. Active stretching can improve frozen shoulder better than supervised neglect, as demonstrated by the improvement of Constant score.

  17. EFFECTIVENESS OF PNF STRETCHING VERSUS STATIC STRETCHING ON PAIN AND HAMSTRING FLEXIBILITY FOLLOWING MOIST HEAT IN INDIVIDUALS WITH KNEE OSTEOARTHRITIS

    OpenAIRE

    Meena .V; Shanthi .C; Madhavi .K

    2016-01-01

    Background: Osteoarthritis (OA) is a degenerative joint disease and one of the major public health problem that causesfunctional impairment and reduced quality of life. To compare the effectiveness of PNF Hold relax stretching versus Static stretching on pain and flexibility of hamstring following moist heat in individuals with knee osteoarthritis. Hamstring tightness is the major problem in knee osteoarthritis individuals. Therefore the need of study is comparing the effectiveness of PNF Hol...

  18. The effect of warm-up, static stretching and dynamic stretching on hamstring flexibility in previously injured subjects

    Directory of Open Access Journals (Sweden)

    Murray Elaine

    2009-04-01

    Full Text Available Abstract Background Warm-up and stretching are suggested to increase hamstring flexibility and reduce the risk of injury. This study examined the short-term effects of warm-up, static stretching and dynamic stretching on hamstring flexibility in individuals with previous hamstring injury and uninjured controls. Methods A randomised crossover study design, over 2 separate days. Hamstring flexibility was assessed using passive knee extension range of motion (PKE ROM. 18 previously injured individuals and 18 uninjured controls participated. On both days, four measurements of PKE ROM were recorded: (1 at baseline; (2 after warm-up; (3 after stretch (static or dynamic and (4 after a 15-minute rest. Participants carried out both static and dynamic stretches, but on different days. Data were analysed using Anova. Results Across both groups, there was a significant main effect for time (p 0.05. Using ANCOVA to adjust for the non-significant (p = 0.141 baseline difference between groups, the previously injured group demonstrated a greater response to warm-up and static stretching, however this was not statistically significant (p = 0.05. Conclusion Warm-up significantly increased hamstring flexibility. Static stretching also increased hamstring flexibility, whereas dynamic did not, in agreement with previous findings on uninjured controls. The effect of warm-up and static stretching on flexibility was greater in those with reduced flexibility post-injury, but this did not reach statistical significance. Further prospective research is required to validate the hypothesis that increased flexibility improves outcomes. Trial Registration ACTRN12608000638336

  19. Cardiovascular Responses to Skeletal Muscle Stretching: "Stretching" the Truth or a New Exercise Paradigm for Cardiovascular Medicine?

    Science.gov (United States)

    Kruse, Nicholas T; Scheuermann, Barry W

    2017-12-01

    Stretching is commonly prescribed with the intended purpose of increasing range of motion, enhancing muscular coordination, and preventing prolonged immobilization induced by aging or a sedentary lifestyle. Emerging evidence suggests that acute or long-term stretching exercise may modulate a variety of cardiovascular responses. Specifically, at the onset of stretch, the mechanical deformation of the vascular bed coupled with stimulation of group III muscle afferent fibers initiates a cascade of events resulting in both peripheral vasodilation and a heart rate-driven increase in cardiac output, blood pressure, and muscle blood flow. This potential to increase shear stress and blood flow without the use of excessive muscle energy expenditure may hold important implications for future therapeutic vascular medicine and cardiac health. However, the idea that a cardiovascular component may be involved in human skeletal muscle stretching is relatively new. Therefore, the primary intent of this review is to highlight topics related to skeletal muscle stretching and cardiovascular regulation and function. The current evidence suggests that acute stretching causes a significant macro- and microcirculatory event that alters blood flow and the relationship between oxygen availability and oxygen utilization. These acute vascular changes if performed chronically may result in improved endothelial function, improved arterial blood vessel stiffness, and/or reduced blood pressure. Although several mechanisms have been postulated, an increased nitric oxide bioavailability has been highlighted as one promising candidate for the improvement in vessel function with stretching. Collectively, the evidence provided in this review suggests that stretching acutely or long term may serve as a novel and alternative low intensity therapeutic intervention capable of improving several parameters of vascular function.

  20. Searching for Kaprekar's constants: algorithms and results

    OpenAIRE

    Walden, Byron L.

    2005-01-01

    We examine some new results on Kaprekar's constants, specifically establishing the unique 7-digit (in base 4) and 9-digit (in base 5) Kaprekar's constants and showing that there are no 15-, 21-, 27-, or 33-digit Kaprekar's constants.

  1. Computing the Gromov hyperbolicity constant of a discrete metric space

    KAUST Repository

    Ismail, Anas

    2012-07-01

    Although it was invented by Mikhail Gromov, in 1987, to describe some family of groups[1], the notion of Gromov hyperbolicity has many applications and interpretations in different fields. It has applications in Biology, Networking, Graph Theory, and many other areas of research. The Gromov hyperbolicity constant of several families of graphs and geometric spaces has been determined. However, so far, the only known algorithm for calculating the Gromov hyperbolicity constant δ of a discrete metric space is the brute force algorithm with running time O (n4) using the four-point condition. In this thesis, we first introduce an approximation algorithm which calculates a O (log n)-approximation of the hyperbolicity constant δ, based on a layering approach, in time O(n2), where n is the number of points in the metric space. We also calculate the fixed base point hyperbolicity constant δr for a fixed point r using a (max, min)−matrix multiplication algorithm by Duan in time O(n2.688)[2]. We use this result to present a 2-approximation algorithm for calculating the hyper-bolicity constant in time O(n2.688). We also provide an exact algorithm to compute the hyperbolicity constant δ in time O(n3.688) for a discrete metric space. We then present some partial results we obtained for designing some approximation algorithms to compute the hyperbolicity constant δ.

  2. Stretched-State Excitations with the

    Science.gov (United States)

    Garcia, Luis Alberto Casimiro

    Neutron time-of-fight spectra were obtained for the ^{14}C(p,n) ^{14}N, ^{18 }O(p,n)^{18}F, and ^{30}Si(p,n) ^{30}P reactions at 135 MeV with the beam-swinger system at the Indiana University Cyclotron Facility. Excitation-energy spectra and the differential cross sections for the observed excitations in these reactions were extracted over the momentum transfer range from 0 to 2.7 fm^{-1}. The primary goal of this work was to obtain the strengths and distributions for the "stretched" states. The identification of these states was based on comparisons of the theoretical differential cross sections, performed in a DWIA formalism, with the experimental cross sections. Isospin assignments were based primarily on comparisons of the measured (p,n) and (e,e^') spectroscopic strengths. Candidate (pid_ {5/2},nu{rm p}_sp {3/2}{-1}), J^ pi = 4 ^- T = 0, 1 and 2, 1 hbaromega states, were identified at E_{x} = 8.5, 13.8, 19.5, and 26.7 MeV in the ^{14}C(p,n) ^{14}N reaction, and the corresponding isovector strengths were extracted. The observed 4^--state excitation energies and the strengths are in good agreement with the analog T = 1 and 2, 4^--states observed in the (e,e^') reaction. Large -basis shell-model calculations were found to predict reasonably well the excitation energies; however, these calculations overpredict the strength by a factor of 2, for the T = 1 and 2 components. In the ^{18}O(p,n) ^{18}F reaction at 135 MeV, (pi d_{5/2},nu {rm d}_sp{5/2}{-1 }) 5^+ T = 0 0hbaromega strength was observed, concentrated in a single state, at E_{x} = 1.1 MeV, with 75% of the extreme-single-particle-model (ESPM) strength, in good agreement with a shell-model calculation. No 6^- 1hbaromega strength was observed in this reaction. Candidate (pi {rm d}_{5/2},nu p _sp{3/2}{-1}) J ^pi = 4^- T = 0, 1 and 2, 1hbaromega states, were identified at E_{x} = 3.9, 9.4, 10.2, 11.4, 12.0, 14.4, 15.3, 17.3, 18.0, 19.7, 21.4, and 23.4 MeV. The observed 4^- T = 2 state excitation energies and

  3. Neural effects of muscle stretching on the spinal reflexes in multiple lower-limb muscles.

    Science.gov (United States)

    Masugi, Yohei; Obata, Hiroki; Inoue, Daisuke; Kawashima, Noritaka; Nakazawa, Kimitaka

    2017-01-01

    While previous studies have shown that muscle stretching suppresses monosynaptic spinal reflex excitability in stretched muscles, its effects on non-stretched muscles is still largely unknown. The purpose of this study was to examine the effects of muscle stretching on monosynaptic spinal reflex in non-stretched muscles. Ten healthy male subjects participated in this study. Muscle stretching of the right triceps surae muscle was performed using a motor torque device for 1 minute. Three different dorsiflexion torques (at approximately 5, 10, and 15 Nm) were applied during muscle stretching. Spinal reflexes evoked by transcutaneous spinal cord stimulation were recorded in both the lower-limb muscles before, during, and at 0 and 5 min following muscle stretching. The amplitudes of the spinal reflexes in both the stretched and non-stretched muscles in the right (ipsilateral) leg were smaller during stretching compared to before, and at 0 and 5 min after stretching. Furthermore, the degree of reduction in the amplitude of the spinal reflexes in the right (ipsilateral) leg muscles increased significantly as the dorsiflexion torque (i.e., stretching of the right triceps surae muscles) increased. In contrast, reduction in the amplitude of the spinal reflexes with increasing dorsiflexion torque was not seen in the left (contralateral) leg muscles. Our results clearly indicate that muscle stretching has inhibitory effects on monosynaptic spinal reflexes, not only in stretched muscles, but also in non-stretched muscles of the ipsilateral leg.

  4. Low power constant fraction discriminator

    International Nuclear Information System (INIS)

    Krishnan, Shanti; Raut, S.M.; Mukhopadhyay, P.K.

    2001-01-01

    This paper describes the design of a low power ultrafast constant fraction discriminator, which significantly reduces the power consumption. A conventional fast discriminator consumes about 1250 MW of power whereas this low power version consumes about 440 MW. In a multi detector system, where the number of discriminators is very large, reduction of power is of utmost importance. This low power discriminator is being designed for GRACE (Gamma Ray Atmospheric Cerenkov Experiments) telescope where 1000 channels of discriminators are required. A novel method of decreasing power consumption has been described. (author)

  5. Can coupling constants be related

    International Nuclear Information System (INIS)

    Nandi, Satyanarayan; Ng, Wing-Chiu.

    1978-06-01

    We analyze the conditions under which several coupling constants in field theory can be related to each other. When the relation is independent of the renormalization point, the relation between any g and g' must satisfy a differential equation as follows from the renormalization group equations. Using this differential equation, we investigate the criteria for the feasibility of a power-series relation for various theories, especially the Weinberg-Salam type (including Higgs bosons) with an arbitrary number of quark and lepton flavors. (orig./WL) [de

  6. Measurement of Newton's gravitational constant

    International Nuclear Information System (INIS)

    Schlamminger, St.; Holzschuh, E.; Kuendig, W.; Nolting, F.; Pixley, R. E.; Schurr, J.; Straumann, U.

    2006-01-01

    A precision measurement of the gravitational constant G has been made using a beam balance. Special attention has been given to determining the calibration, the effect of a possible nonlinearity of the balance and the zero-point variation of the balance. The equipment, the measurements, and the analysis are described in detail. The value obtained for G is 6.674 252(109)(54)x10 -11 m 3 kg -1 s -2 . The relative statistical and systematic uncertainties of this result are 16.3x10 -6 and 8.1x10 -6 , respectively

  7. Exact constants in approximation theory

    CERN Document Server

    Korneichuk, N

    1991-01-01

    This book is intended as a self-contained introduction for non-specialists, or as a reference work for experts, to the particular area of approximation theory that is concerned with exact constants. The results apply mainly to extremal problems in approximation theory, which in turn are closely related to numerical analysis and optimization. The book encompasses a wide range of questions and problems: best approximation by polynomials and splines; linear approximation methods, such as spline-approximation; optimal reconstruction of functions and linear functionals. Many of the results are base

  8. Kolmogorov's constant and local interactions

    International Nuclear Information System (INIS)

    Kraichnan, R.H.

    1987-01-01

    Suppose that all the wave-vector triad interactions that involve no wavenumber ratio that exceeds β are removed from the Navier--Stokes equation. Within a class of closures, the paradoxical effect is to enhance energy cascade through the Kolmogorov inertial range for 1<β<β/sub c/, where β/sub c/ may be as large as 8. This may have implications with regard to force-free structures in the true Navier--Stokes dynamics

  9. Gel stretch method: a new method to measure constitutive properties of cardiac muscle cells

    Science.gov (United States)

    Zile, M. R.; Cowles, M. K.; Buckley, J. M.; Richardson, K.; Cowles, B. A.; Baicu, C. F.; Cooper G, I. V.; Gharpuray, V.

    1998-01-01

    Diastolic dysfunction is an important cause of congestive heart failure; however, the basic mechanisms causing diastolic congestive heart failure are not fully understood, especially the role of the cardiac muscle cell, or cardiocyte, in this process. Before the role of the cardiocyte in this pathophysiology can be defined, methods for measuring cardiocyte constitutive properties must be developed and validated. Thus this study was designed to evaluate a new method to characterize cardiocyte constitutive properties, the gel stretch method. Cardiocytes were isolated enzymatically from normal feline hearts and embedded in a 2% agarose gel containing HEPES-Krebs buffer and laminin. This gel was cast in a shape that allowed it to be placed in a stretching device. The ends of the gel were held between a movable roller and fixed plates that acted as mandibles. Distance between the right and left mandibles was increased using a stepper motor system. The force applied to the gel was measured by a force transducer. The resultant cardiocyte strain was determined by imaging the cells with a microscope, capturing the images with a CCD camera, and measuring cardiocyte and sarcomere length changes. Cardiocyte stress was characterized with a finite-element method. These measurements of cardiocyte stress and strain were used to determine cardiocyte stiffness. Two variables affecting cardiocyte stiffness were measured, the passive elastic spring and viscous damping. The passive spring was assessed by increasing the force on the gel at 1 g/min, modeling the resultant stress vs. strain relationship as an exponential [sigma = A/k(ekepsilon - 1)]. In normal cardiocytes, A = 23.0 kN/m2 and k = 16. Viscous damping was assessed by examining the loop area between the stress vs. strain relationship during 1 g/min increases and decreases in force. Normal cardiocytes had a finite loop area = 1.39 kN/m2, indicating the presence of viscous damping. Thus the gel stretch method provided accurate

  10. Morphogenesis of 3D vascular networks is regulated by tensile forces

    Science.gov (United States)

    Rosenfeld, Dekel; Landau, Shira; Shandalov, Yulia; Raindel, Noa; Freiman, Alina; Shor, Erez; Blinder, Yaron; Vandenburgh, Herman H.; Mooney, David J.; Levenberg, Shulamit

    2016-01-01

    Understanding the forces controlling vascular network properties and morphology can enhance in vitro tissue vascularization and graft integration prospects. This work assessed the effect of uniaxial cell-induced and externally applied tensile forces on the morphology of vascular networks formed within fibroblast and endothelial cell-embedded 3D polymeric constructs. Force intensity correlated with network quality, as verified by inhibition of force and of angiogenesis-related regulators. Tensile forces during vessel formation resulted in parallel vessel orientation under static stretching and diagonal orientation under cyclic stretching, supported by angiogenic factors secreted in response to each stretch protocol. Implantation of scaffolds bearing network orientations matching those of host abdominal muscle tissue improved graft integration and the mechanical properties of the implantation site, a critical factor in repair of defects in this area. This study demonstrates the regulatory role of forces in angiogenesis and their capacities in vessel structure manipulation, which can be exploited to improve scaffolds for tissue repair. PMID:26951667

  11. Extracting local stretching from left ventricle angiography data

    Science.gov (United States)

    Mishra, Sanjoy K.; Goldgof, Dmitry B.

    1991-07-01

    This paper presents a new method for extracting local surface stretching from the left ventricle (LV) cineangiography data. The algorithm is based on Gaussian curvature for surface stretching recovery under more realistic conformal motion assumption. During conformal motion surface stretching can vary over the surface patch. In particular, surface stretching can be approximated using linear or quadratic (or higher order) functions. Then, coefficients of the approximating function can be calculated and surface stretching computed from changes in surface curvature at corresponding points. For example, linear approximation requires three point correspondences (between consecutive time frames) within small surface patch. The authors demonstrate the higher precision of the new approach (as compared to homothetic assumption in the authors' earlier work) on simulated and real data of the left ventricle of the human heart. The data set was provided by Dr. Alistair Young of the University of Auckland, New Zealand, and consists of the tracked locations of eleven bifurcation points of the left coronary artery and the tracked locations of 292 vessel points for one cardiac cycle (60 frames/cycle).

  12. Controlled cyclic stretch bioreactor for tissue-engineered heart valves.

    Science.gov (United States)

    Syedain, Zeeshan H; Tranquillo, Robert T

    2009-09-01

    A tissue-engineered heart valve (TEHV) represents the ultimate valve replacement, especially for juvenile patients given its growth potential. To date, most TEHV bioreactors have been developed based on pulsed flow of culture medium through the valve lumen to induce strain in the leaflets. Using a strategy for controlled cyclic stretching of tubular constructs reported previously, we developed a controlled cyclic stretch bioreactor for TEHVs that leads to improved tensile and compositional properties. The TEHV is mounted inside a latex tube, which is then cyclically pressurized with culture medium. The root and leaflets stretch commensurately with the latex, the stretching being dictated by the stiffer latex and thus controllable. Medium is also perfused through the lumen at a slow rate in a flow loop to provide nutrient delivery. Fibrin-based TEHVs prepared with human dermal fibroblasts were subjected to three weeks of cyclic stretching with incrementally increasing strain amplitude. The TEHV possessed the tensile stiffness and stiffness anisotropy of leaflets from sheep pulmonary valves and could withstand cyclic pulmonary pressures with similar distension as for a sheep pulmonary artery.

  13. Influence of chronic stretching on muscle performance: Systematic review.

    Science.gov (United States)

    Medeiros, D M; Lima, C S

    2017-08-01

    The aim of the current study was to investigate the influence of chronic stretching on muscle performance (MP) by a systematic review. The search strategy included MEDLINE, PEDro, Cochrane CENTRAL, LILACS, and manual search from inception to June 2016. Randomized and controlled clinical trials, non-randomized, and single group studies that have analyzed the influence of flexibility training (FT) (using any stretching technique) on MP were included. Differently, studies with special populations (children, elderly, and people with any dysfunction/disease), and articles that have used FT protocols shorter than three weeks or 12 sessions were excluded. The MP assessment could have been performed by functional tests (e.g. jump, sprint, stretch-shortening cycle tasks), isometric contractions, and/or isotonic contractions. Twenty-eight studies were included out of 513. Seven studies evaluated MP by stretch-shortening cycle tasks, Ten studies evaluated MP by isometric contractions, and 13 studies assessed MP by isotonic contractions. We were unable to perform a meta-analysis due to the high heterogeneity among the included studies. In an individual study level analysis, we identified that 14 studies found positive effects of chronic stretching on MP. The improvements were observed only in functional tests and isotonic contractions, isometric contractions were not affected by FT. Therefore, FT might have an influence on dynamic MP. However, more studies are necessary to confirm whether FT can positively affect MP. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Direct measurements of intermolecular forces by chemical force microscopy

    Science.gov (United States)

    Vezenov, Dmitri Vitalievich

    1999-12-01

    Detailed description of intermolecular forces is key to understanding a wide range of phenomena from molecular recognition to materials failure. The unique features of atomic force microscopy (AFM) to make point contact force measurements with ultra high sensitivity and to generate spatial maps of surface topography and forces have been extended to include measurements between well-defined organic molecular groups. Chemical modification of AFM probes with self-assembled monolayers (SAMs) was used to make them sensitive to specific molecular interactions. This novel chemical force microscopy (CFM) technique was used to probe forces between different molecular groups in a range of environments (vacuum, organic liquids and aqueous solutions); measure surface energetics on a nanometer scale; determine pK values of the surface acid and base groups; measure forces to stretch and unbind a short synthetic DNA duplex and map the spatial distribution of specific functional groups and their ionization state. Studies of adhesion forces demonstrated the important contribution of hydrogen bonding to interactions between simple organic functionalities. The chemical identity of the tip and substrate surfaces as well as the medium had a dramatic effect on adhesion between model monolayers. A direct correlation between surface free energy and adhesion forces was established. The adhesion between epoxy polymer and model mixed SAMs varied with the amount of hydrogen bonding component in the monolayers. A consistent interpretation of CFM measurements in polar solvents was provided by contact mechanics models and intermolecular force components theory. Forces between tips and surfaces functionalized with SAMs terminating in acid or base groups depended on their ionization state. A novel method of force titration was introduced for highly local characterization of the pK's of surface functional groups. The pH-dependent changes in friction forces were exploited to map spatially the

  15. Investigating the role of musical genre in human perception of music stretching resistance

    OpenAIRE

    Chen, Jun; Wang, Chaokun

    2017-01-01

    To stretch a music piece to a given length is a common demand in people's daily lives, e.g., in audio-video synchronization and animation production. However, it is not always guaranteed that the stretched music piece is acceptable for general audience since music stretching suffers from people's perceptual artefacts. Over-stretching a music piece will make it uncomfortable for human psychoacoustic hearing. The research on music stretching resistance attempts to estimate the maximum stretchab...

  16. Stretched proton-neutron configurations in fp-shell nuclei. Pt. 1

    International Nuclear Information System (INIS)

    Fister, U.; Jahn, R.; Neumann-Cosel, P. von; Schenk, P.; Trelle, T.K.; Wenzel, D.; Wienands, U.

    1994-01-01

    The (α, d) reaction has been investigated at bombarding energies around 55 MeV on 40,42,44,48 Ca, 50,52,54 Cr, 54,56,58 Fe, 58,60,62,64 Ni, 64,66 Zn and 70,72 Ge targets. The angular distributions of prominent transitions were analyzed with the distorted-wave Born approximation and shown to correspond to unnatural-parity stretched proton-neutron configurations. Strong transitions of (g 9/2 ) 2 9 + and (p 3/2 , g 9/2 ) 6 - character were identified in most final nuclei. Additionally, dominant transitions with (f 7/2 , g 9/2 ) 8 - structure were observed for target nuclei with an open proton f 7/2 shell. These stretched high-spin states could be consistently described by an average normalization constant N = 225 ± 85 indicating their relatively pure two-nucleon structure. In the lower-mass Sc and Mn isotopes, configurations built on g 9/2 states are increasingly damped because of the strong fragmentation of the underlying single-particle strength. (orig.)

  17. Dynamic Contractility and Efficiency Impairments in Stretch-Shortening Cycle Are Stretch-Load-Dependent After Training-Induced Muscle Damage

    NARCIS (Netherlands)

    Vaczi, Mark; Racz, Levente; Hortobagyi, Tibor; Tihanyi, Jozsef

    Vaczi, M, Racz, L, Hortobagyi, T, and Tihanyi, J. Dynamic contractility and efficiency impairments in stretch-shortening cycle are stretch-load-dependent after training-induced muscle damage. J Strength Cond Res 27(8): 2171-2179, 2013To determine the acute task and stretch-load dependency of

  18. Phase transitions in single macromolecules: Loop-stretch transition versus loop adsorption transition in end-grafted polymer chains

    Science.gov (United States)

    Zhang, Shuangshuang; Qi, Shuanhu; Klushin, Leonid I.; Skvortsov, Alexander M.; Yan, Dadong; Schmid, Friederike

    2018-01-01

    We use Brownian dynamics simulations and analytical theory to compare two prominent types of single molecule transitions. One is the adsorption transition of a loop (a chain with two ends bound to an attractive substrate) driven by an attraction parameter ɛ and the other is the loop-stretch transition in a chain with one end attached to a repulsive substrate, driven by an external end-force F applied to the free end. Specifically, we compare the behavior of the respective order parameters of the transitions, i.e., the mean number of surface contacts in the case of the adsorption transition and the mean position of the chain end in the case of the loop-stretch transition. Close to the transition points, both the static behavior and the dynamic behavior of chains with different length N are very well described by a scaling ansatz with the scaling parameters (ɛ - ɛ*)Nϕ (adsorption transition) and (F - F*)Nν (loop-stretch transition), respectively, where ϕ is the crossover exponent of the adsorption transition and ν is the Flory exponent. We show that both the loop-stretch and the loop adsorption transitions provide an exceptional opportunity to construct explicit analytical expressions for the crossover functions which perfectly describe all simulation results on static properties in the finite-size scaling regime. Explicit crossover functions are based on the ansatz for the analytical form of the order parameter distributions at the respective transition points. In contrast to the close similarity in equilibrium static behavior, the dynamic relaxation at the two transitions shows qualitative differences, especially in the strongly ordered regimes. This is attributed to the fact that the surface contact dynamics in a strongly adsorbed chain is governed by local processes, whereas the end height relaxation of a strongly stretched chain involves the full spectrum of Rouse modes.

  19. Effect of Pre-Procedural Chair-Side Finger Stretches on Pinch Strength amongst Dental Cohort- A Biomechanical Study.

    Science.gov (United States)

    Padhye, Ninad Milind; Padhye, Ashvini Mukul; Gupta, Himani Swatantrakumar

    2017-04-01

    Ergonomics is the essential principle behind the health and successful practice for a dentist and dental hygienist. During the procedure of dental Scaling and Root Planing (SRP), a high level of pinch force is exerted by the finger muscles resulting in early muscle fatigue. This pilot study comparatively evaluated the Pinch Strength (PS) of the finger muscles, prior to and after SRP, amongst dental cohort performing chair-side hand and finger stretches to those not performing the same. Forty dental professionals were recruited by purposive sampling for the study and allocated into a test and control group. PS was recorded for both groups following which the test group performed finger stretches comprising of rubber band stretch, tendon glide, finger flexion and extension, thumb flexion and finger webbing. The subjects of both the groups carried out SRP for 30 minutes after which PS was again recorded. Inter-group difference was analysed for variability at baseline and 30 minutes after SRP using independent samples/unpaired t-test. Within group comparison of PS measurement was done using paired t-test. The PS for the test group declined from 14.425±2.577 pounds (lbs) to 13.725±2.557 lbs, while for the control group, a decline in PS from 13.65±2.636 lbs to 10.675±2.478 lbs after SRP was noted. On comparing the difference of means of both groups, a statistically significant result was obtained. Work-related musculoskeletal disorders can be reduced by performing a few simple chair-side stretches. These stretches can help prevent the finger muscle fatigue during SRP and thus, increase its efficacy.

  20. Tail modeling in a stretched magnetosphere. I - Methods and transformations

    Science.gov (United States)

    Stern, David P.

    1987-01-01

    A new method is developed for representing the magnetospheric field B as a distorted dipole field. Because Delta-B = 0 must be maintained, such a distortion may be viewed as a transformation of the vector potential A. The simplest form is a one-dimensional 'stretch transformation' along the x axis, concisely represented by the 'stretch function' f(x), which is also a convenient tool for representing features of the substorm cycle. One-dimensional stretch transformations are extended to spherical, cylindrical, and parabolic coordinates and then to arbitrary coordinates. It is shown that distortion transformations can be viewed as mappings of field lines from one pattern to another; the final result only requires knowledge of the field and not of the potentials. General transformations in Cartesian and arbitrary coordinates are derived, and applications to field modeling, field line motion, MHD modeling, and incompressible fluid dynamics are considered.

  1. Alignment of Disks with Lagrangian Stretching in Turbulence

    Science.gov (United States)

    Hunt, Conor; Tierney, Lydia; Kramel, Stefan; Voth, Greg

    2015-11-01

    We study Lagrangian stretching in isotropic turbulence in order to understand both the rotations of disks and the preferential alignment of vorticity with the intermediate strain rate eigenvector. Using velocity gradient tensors from a numerical simulation of homogeneous isotropic turbulence at Rλ = 180, we calculate the Cauchy-Green strain tensors whose eigenvectors provide a natural basis for studying stretching phenomenon. Previous work has shown that rods preferentially align with the vorticity as a result of both quantities independently aligning with the extensional Cauchy-Green eigenvector. In contrast, disks orient with their symmetry axis perpendicular to vorticity and preferentially align with the compressional Cauchy-Green eigenvector. We also find that the intermediate strain rate eigenvector is aligned with the extensional Cauchy-Green eigenvector. A natural consequence is that the intermediate strain rate eigenvector is aligned with the vorticity vector since conservation of angular momentum aligns vorticity with the direction it has been stretched.

  2. Stretching of red blood cells at high strain rates

    Science.gov (United States)

    Mancuso, J. E.; Ristenpart, W. D.

    2017-10-01

    Most work on the mechanical behavior of red blood cells (RBCs) in flow has focused on simple shear flows. Relatively little work has examined RBC deformations in the physiologically important extensional flow that occurs at the entrance to a constriction. In particular, previous work suggests that RBCs rapidly stretch out and then retract upon entering the constriction, but to date no model predicts this behavior for the extremely high strain rates typically experienced there. In this Rapid Communication, we use high speed video to perform systematic measurements of the dynamic stretching behavior of RBCs as they enter a microfluidic constriction. We demonstrate that both the Kelvin-Voigt and Skalak viscoelastic models capture the observed stretching dynamics, up to strain rates as high as 2000 s-1. The results indicate that the effective elastic modulus of the RBC membrane at these strain rates is an order of magnitude larger than moduli measured by micropipette aspiration or other low strain rate techniques.

  3. Effects of static stretching on 1-mile uphill run performance.

    Science.gov (United States)

    Lowery, Ryan P; Joy, Jordan M; Brown, Lee E; Oliveira de Souza, Eduardo; Wistocki, David R; Davis, Gregory S; Naimo, Marshall A; Zito, Gina A; Wilson, Jacob M

    2014-01-01

    It is previously demonstrated that static stretching was associated with a decrease in running economy and distance run during a 30-minute time trial in trained runners. Recently, the detrimental effects of static stretching on economy were found to be limited to the first few minutes of an endurance bout. However, economy remains to be studied for its direct effects on performance during shorter endurance events. The aim of this study was to investigate the effects of static stretching on 1-mile uphill run performance, electromyography (EMG), ground contact time (GCT), and flexibility. Ten trained male distance runners aged 24 ± 5 years with an average VO2max of 64.9 ± 6.5 mL·kg-1·min-1 were recruited. Subjects reported to the laboratory on 3 separate days interspersed by 72 hours. On day 1, anthropometrics and V[Combining Dot Above]O2max were determined on a motor-driven treadmill. On days 2 and 3, subjects performed a 5-minute treadmill warm-up and either performed a series of 6 lower-body stretches for three 30-second repetitions or sat still for 10 minutes. Time to complete a 1-mile run under stretching and nonstretching conditions took place in randomized order. For the performance run, subjects were instructed to run as fast as possible at a set incline of 5% until a distance of 1 mile was completed. Flexibility from the sit and reach test, EMG, GCT, and performance, determined by time to complete the 1-mile run, were recorded after each condition. Time to complete the run was significantly less (6:51 ± 0:28 minutes) in the nonstretching condition as compared with the stretching condition (7:04 ± 0:32 minutes). A significant condition-by-time interaction for muscle activation existed, with no change in the nonstretching condition (pre 91.3 ± 11.6 mV to post 92.2 ± 12.9 mV) but increased in the stretching condition (pre 91.0 ± 11.6 mV to post 105.3 ± 12.9 mV). A significant condition-by-time interaction for GCT was also present, with no changes in

  4. Directional Cell Migration in Response to Repeated Substratum Stretching

    Science.gov (United States)

    Okimura, Chika; Iwadate, Yoshiaki

    2017-10-01

    Crawling migration plays an essential role in a variety of biological phenomena, including development, wound healing, and immune system function. Migration properties such as anterior-posterior polarity, directionality, and velocity are regulated not only by the reception of a chemoattractant but also by sensing mechanical inputs from the external environment. In this review, we describe the mechanical response of migrating cells, particularly under repeated stretching of the elastic substratum, highlighting the fact that there appear to be two independent mechanosensing systems that generate the polarity needed for migration. Cells that have no stress fibers, such as Dictyostelium cells and neutrophil-like differentiated HL-60 cells, migrate perpendicular to the stretching direction via myosin II localization. Cells that do possess stress fibers, however, such as fish keratocytes, migrate parallel to the stretching via a stress-fiber-dependent process.

  5. Labor Force

    Science.gov (United States)

    Occupational Outlook Quarterly, 2012

    2012-01-01

    The labor force is the number of people ages 16 or older who are either working or looking for work. It does not include active-duty military personnel or the institutionalized population, such as prison inmates. Determining the size of the labor force is a way of determining how big the economy can get. The size of the labor force depends on two…

  6. Short Term Effects of Neurodynamic Stretching and Static Stretching Techniques on Hamstring Muscle Flexibility in Healthy Male Subjects

    Directory of Open Access Journals (Sweden)

    Adel Rashad Ahmed

    2016-05-01

    Full Text Available Flexibility is a key component of rehabilitation and inadequate muscle extensibility remains a commonly accepted factor for musculoskeletal disorders. Studies on the most optimal technique for improving muscle flexibility are a widely debated. The aim of the study was to compare the effectiveness of neurodynamic and static stretching techniques on hamstring flexibility in healthy male subjects. This study was a randomized experimental trial; forty healthy male subjects with hamstring tightness were randomly divided into two equal groups: The neurodynamic group and the static stretching group. Treatment was given for 5 consecutive days and the outcomes were measured using Active knee Extension Test and Straight Leg Raising. There was a significant improvement in hamstring flexibility following application of both neurodynamic and static stretching but the improvement in the neurodynamic group (p<0.001 was better than that of the static group (p<0.02. Results suggest that a neurodynamic stretching could increase hamstring flexibility to a greater extent than static stretching in healthy male subjects with a tight hamstring.

  7. The fundamental constants a mystery of physics

    CERN Document Server

    Fritzsch, Harald

    2009-01-01

    The speed of light, the fine structure constant, and Newton's constant of gravity — these are just three among the many physical constants that define our picture of the world. Where do they come from? Are they constant in time and across space? In this book, physicist and author Harald Fritzsch invites the reader to explore the mystery of the fundamental constants of physics in the company of Isaac Newton, Albert Einstein, and a modern-day physicist

  8. Omnidirectional antenna having constant phase

    Energy Technology Data Exchange (ETDEWEB)

    Sena, Matthew

    2017-04-04

    Various technologies presented herein relate to constructing and/or operating an antenna having an omnidirectional electrical field of constant phase. The antenna comprises an upper plate made up of multiple conductive rings, a lower ground-plane plate, a plurality of grounding posts, a conical feed, and a radio frequency (RF) feed connector. The upper plate has a multi-ring configuration comprising a large outer ring and several smaller rings of equal size located within the outer ring. The large outer ring and the four smaller rings have the same cross-section. The grounding posts ground the upper plate to the lower plate while maintaining a required spacing/parallelism therebetween.

  9. Constant Proportion Debt Obligations (CPDOs)

    DEFF Research Database (Denmark)

    Cont, Rama; Jessen, Cathrine

    2012-01-01

    be made arbitrarily small—and thus the credit rating arbitrarily high—by increasing leverage, but the ratings obtained strongly depend on assumptions on the credit environment (high spread or low spread). More importantly, CPDO loss distributions are found to exhibit a wide range of tail risk measures......Constant Proportion Debt Obligations (CPDOs) are structured credit derivatives that generate high coupon payments by dynamically leveraging a position in an underlying portfolio of investment-grade index default swaps. CPDO coupons and principal notes received high initial credit ratings from...... the major rating agencies, based on complex models for the joint transition of ratings and spreads for all names in the underlying portfolio. We propose a parsimonious model for analysing the performance of CPDO strategies using a top-down approach that captures the essential risk factors of the CPDO. Our...

  10. Can Treadmill Perturbations Evoke Stretch Reflexes in the Calf Muscles?

    Science.gov (United States)

    Sloot, Lizeth H; van den Noort, Josien C; van der Krogt, Marjolein M; Bruijn, Sjoerd M; Harlaar, Jaap

    2015-01-01

    Disinhibition of reflexes is a problem amongst spastic patients, for it limits a smooth and efficient execution of motor functions during gait. Treadmill belt accelerations may potentially be used to measure reflexes during walking, i.e. by dorsal flexing the ankle and stretching the calf muscles, while decelerations show the modulation of reflexes during a reduction of sensory feedback. The aim of the current study was to examine if belt accelerations and decelerations of different intensities applied during the stance phase of treadmill walking can evoke reflexes in the gastrocnemius, soleus and tibialis anterior in healthy subjects. Muscle electromyography and joint kinematics were measured in 10 subjects. To determine whether stretch reflexes occurred, we assessed modelled musculo-tendon length and stretch velocity, the amount of muscle activity, as well as the incidence of bursts or depressions in muscle activity with their time delays, and co-contraction between agonist and antagonist muscle. Although the effect on the ankle angle was small with 2.8±1.0°, the perturbations caused clear changes in muscle length and stretch velocity relative to unperturbed walking. Stretched muscles showed an increasing incidence of bursts in muscle activity, which occurred after a reasonable electrophysiological time delay (163-191 ms). Their amplitude was related to the muscle stretch velocity and not related to co-contraction of the antagonist muscle. These effects increased with perturbation intensity. Shortened muscles showed opposite effects, with a depression in muscle activity of the calf muscles. The perturbations only slightly affected the spatio-temporal parameters, indicating that normal walking was retained. Thus, our findings showed that treadmill perturbations can evoke reflexes in the calf muscles and tibialis anterior. This comprehensive study could form the basis for clinical implementation of treadmill perturbations to functionally measure reflexes during

  11. Can Treadmill Perturbations Evoke Stretch Reflexes in the Calf Muscles?

    Directory of Open Access Journals (Sweden)

    Lizeth H Sloot

    Full Text Available Disinhibition of reflexes is a problem amongst spastic patients, for it limits a smooth and efficient execution of motor functions during gait. Treadmill belt accelerations may potentially be used to measure reflexes during walking, i.e. by dorsal flexing the ankle and stretching the calf muscles, while decelerations show the modulation of reflexes during a reduction of sensory feedback. The aim of the current study was to examine if belt accelerations and decelerations of different intensities applied during the stance phase of treadmill walking can evoke reflexes in the gastrocnemius, soleus and tibialis anterior in healthy subjects. Muscle electromyography and joint kinematics were measured in 10 subjects. To determine whether stretch reflexes occurred, we assessed modelled musculo-tendon length and stretch velocity, the amount of muscle activity, as well as the incidence of bursts or depressions in muscle activity with their time delays, and co-contraction between agonist and antagonist muscle. Although the effect on the ankle angle was small with 2.8±1.0°, the perturbations caused clear changes in muscle length and stretch velocity relative to unperturbed walking. Stretched muscles showed an increasing incidence of bursts in muscle activity, which occurred after a reasonable electrophysiological time delay (163-191 ms. Their amplitude was related to the muscle stretch velocity and not related to co-contraction of the antagonist muscle. These effects increased with perturbation intensity. Shortened muscles showed opposite effects, with a depression in muscle activity of the calf muscles. The perturbations only slightly affected the spatio-temporal parameters, indicating that normal walking was retained. Thus, our findings showed that treadmill perturbations can evoke reflexes in the calf muscles and tibialis anterior. This comprehensive study could form the basis for clinical implementation of treadmill perturbations to functionally

  12. Similarity Solutions for Flow and Heat Transfer of Non-Newtonian Fluid over a Stretching Surface

    Directory of Open Access Journals (Sweden)

    Atta Sojoudi

    2014-01-01

    Full Text Available Similarity solutions are carried out for flow of power law non-Newtonian fluid film on unsteady stretching surface subjected to constant heat flux. Free convection heat transfer induces thermal boundary layer within a semi-infinite layer of Boussinesq fluid. The nonlinear coupled partial differential equations (PDE governing the flow and the boundary conditions are converted to a system of ordinary differential equations (ODE using two-parameter groups. This technique reduces the number of independent variables by two, and finally the obtained ordinary differential equations are solved numerically for the temperature and velocity using the shooting method. The thermal and velocity boundary layers are studied by the means of Prandtl number and non-Newtonian power index plotted in curves.

  13. Quantifying the passive stretching response of human tibialis anterior muscle using shear wave elastography.

    Science.gov (United States)

    Koo, Terry K; Guo, Jing-Yi; Cohen, Jeffrey H; Parker, Kevin J

    2014-01-01

    Quantifying passive stretching responses of individual muscles helps the diagnosis of muscle disorders and aids the evaluation of surgical/rehabilitation treatments. Utilizing an animal model, we demonstrated that shear elastic modulus measured by supersonic shear wave elastography increases linearly with passive muscle force. This study aimed to use this state-of-the-art technology to study the relationship between shear elastic modulus and ankle dorsi-plantarflexion angle of resting tibialis anterior muscles and extract physiologically meaningful parameters from the elasticity-angle curve to better quantify passive stretching responses. Elasticity measurements were made at resting tibialis anterior of 20 healthy subjects with the ankle positioned from 50° plantarflexion to up to 15° dorsiflexion at every 5° for two cycles. Elasticity-angle data was curve-fitted by optimizing slack angle, slack elasticity, and rate of increase in elasticity within a piecewise exponential model. Elasticity-angle data of all subjects were well fitted by the piecewise exponential model with coefficients of determination ranging between 0.973 and 0.995. Mean (SD) of slack angle, slack elasticity, and rate of increase in elasticity were 10.9° (6.3°), 5.8 (1.9) kPa, and 0.0347 (0.0082) respectively. Intraclass correlation coefficients of each parameter were 0.852, 0.942, and 0.936 respectively, indicating excellent test-retest reliability. This study demonstrated the feasibility of using supersonic shear wave elastography to quantify passive stretching characteristics of individual muscle and provided preliminary normative values of slack angle, slack elasticity, and rate of increase in elasticity for human tibialis anterior muscles. Future studies will investigate diagnostic values of these parameters in clinical applications. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. The cosmological constant. A small addition with a great effect

    International Nuclear Information System (INIS)

    Lessner, G.

    1999-01-01

    The consequences of a cosmological constant Λ to cosmological models on the one hand and to Newton's gravitational law in the weak field expansion on the other hand are discussed. In case of a negative Λ with Λ∼10 -56 cm -2 the universe is open but does not expand forever. Furthermore, its age is compatible with the age of the oldest globular clusters. On the other hand, Newton's gravitational law is modified by an additional attractive force term linearly increasing woth the distance. This term acts only over very large distances. If one assumes a value Λ∼=-10 -56 cm -2 the additional term acts for stars over a characteristic scale of about 120 pc and for galaxies over a characteristic scale of about 0.8 Mpc. A positive cosmological constant Λ∼=-10 -56 cm -2 leads to an additional repulsive force which would have prevented the existence of galaxy clusters

  15. Stretching, twisting and supercoiling in short, single DNA molecules

    Science.gov (United States)

    Lam, Pui-Man; Zhen, Yi

    2018-02-01

    We had combined the Neukirch-Marko model that describes the extension, torque and supercoiling in single, stretched and twisted DNA of infinite contour length, with a form of the free energy suggested by Sinha and Samuels to describe short DNA, with contour length only a few times the persistence length. We find that the free energy of the stretched but untwisted DNA, is significantly modified from its infinitely length value and this in turn modifies significantly the torque and supercoiling. We show that this is consistent with short DNA being more flexible than infinitely long DNA. We hope our results will stimulate experimental investigation of torque and supercoiling in short DNA.

  16. Cell volume and membrane stretch independently control K+ channel activity

    DEFF Research Database (Denmark)

    Bomholtz, Sofia Hammami; Willumsen, Niels J; Olsen, Hervør L

    2009-01-01

    A number of potassium channels including members of the KCNQ family and the Ca(2+) activated IK and SK, but not BK, are strongly and reversibly regulated by small changes in cell volume. It has been argued that this general regulation is mediated through sensitivity to changes in membrane stretch....... To test this hypothesis we have studied the regulation of KCNQ1 and BK channels after expression in Xenopus oocytes. Results from cell-attached patch clamp studies (approximately 50 microm(2) macropatches) in oocytes expressing BK channels demonstrate that the macroscopic volume-insensitive BK current...... that stretch and volume sensitivity can be considered two independent regulatory mechanisms....

  17. Management of stretch marks (with a focus on striae rubrae

    Directory of Open Access Journals (Sweden)

    Uwe Wollina

    2017-01-01

    Full Text Available Stretch marks are one of the most common benign cutaneous lesions and encountered esthetic problems. Striae rubrae and striae albae can be differentiated on the basis of clinical appearance. Histologically, disturbances of the dermal fiber network and local expression of receptors for sexual steroids have been detected. The epidermal changes are secondary. Prevention of stretch marks using topical ointments and oils is debatable. Treatment of striae rubrae by lasers and light devices improves appearance. Microneedling and non-ablative and fractionated lasers have been used. This review provides an overview on current treatment options with a special focus on laser treatments.

  18. Stretching Your Energetic Budget: How Tendon Compliance Affects the Metabolic Cost of Running.

    Directory of Open Access Journals (Sweden)

    Thomas K Uchida

    Full Text Available Muscles attach to bones via tendons that stretch and recoil, affecting muscle force generation and metabolic energy consumption. In this study, we investigated the effect of tendon compliance on the metabolic cost of running using a full-body musculoskeletal model with a detailed model of muscle energetics. We performed muscle-driven simulations of running at 2-5 m/s with tendon force-strain curves that produced between 1 and 10% strain when the muscles were developing maximum isometric force. We computed the average metabolic power consumed by each muscle when running at each speed and with each tendon compliance. Average whole-body metabolic power consumption increased as running speed increased, regardless of tendon compliance, and was lowest at each speed when tendon strain reached 2-3% as muscles were developing maximum isometric force. When running at 2 m/s, the soleus muscle consumed less metabolic power at high tendon compliance because the strain of the tendon allowed the muscle fibers to operate nearly isometrically during stance. In contrast, the medial and lateral gastrocnemii consumed less metabolic power at low tendon compliance because less compliant tendons allowed the muscle fibers to operate closer to their optimal lengths during stance. The software and simulations used in this study are freely available at simtk.org and enable examination of muscle energetics with unprecedented detail.

  19. Global stability of an SEIR epidemic model with constant immigration

    International Nuclear Information System (INIS)

    Li Guihua; Wang Wendi; Jin Zhen

    2006-01-01

    An SEIR epidemic model with the infectious force in the latent (exposed), infected and recovered period is studied. It is assumed that susceptible and exposed individuals have constant immigration rates. The model exhibits a unique endemic state if the fraction p of infectious immigrants is positive. If the basic reproduction number R is greater than 1, sufficient conditions for the global stability of the endemic equilibrium are obtained by the compound matrix theory

  20. COMBINED EFFECT OF PNF STRETCHING WITH CHEST MOBILITY EXERCISES ON CHEST EXPANSION AND PULMONARY FUNCTIONS FOR ELDERLY

    Directory of Open Access Journals (Sweden)

    Vinod Babu .K

    2015-06-01

    Full Text Available Background: PNF stretching and chest mobility exercises found to be effective in elder patients, however the combined effectiveness of these techniques were unknown. The purpose of this study is to find the effect of Hold-relax PNF stretching technique for pectoralis muscle combined with chest mobility exercises on improvement of chest expansion and pulmonary function for elderly subjects. Method: An Experimental study design, 30 subjects with age group above 60 years were randomized 15 subjects each into Study and Control group. Control group received Supervised Active Assisted Exercise Program while Study group received Hold-relax PNF Stretching for pectoralis muscle, Chest Mobility Exercises Program and supervised Active Assisted Exercise Program for a period of one week. Outcome measures such as chest expansion at axilla and xiphisternum and pulmonary function test such as FEV1, FVC and FEV1/FVC were measured before and after one week of treatment. Results: Analysis using paired ‘t’ test within the group found that there is no statistically significant difference within control group where as there is a statistical significant difference within study group. Comparative analysis of pre-intervention means shown that there is no statistically significant difference between the groups. Comparative analysis of post-intervention means shown that there is a statistically significant difference in means of Chest expansion, FEV1/FVC and there is no statistical significant difference in FEV1 and FVC between study and control groups. Conclusion: It is concluded that one week of combined Hold-relax PNF stretching for pectoralis muscle with chest mobility exercises shown significant improvement in chest expansion and pulmonary function test such as forced expiratory volume and forced vital capacity than only active assisted exercise program for elderly subjects.

  1. Calculation of Elastic Bond Constants in Atomistic Strain Analysis.

    Science.gov (United States)

    Chen, Haiyuan; Wang, Juanjuan; Ashalley, Eric; Li, Handong; Niu, Xiaobin

    2015-12-01

    Strain analysis has significance both for tailoring material properties and designing nanoscale devices. In particular, strain plays a vital role in engineering the growth thermodynamics and kinetics and is applicable for designing optoelectronic devices. In this paper, we present a methodology for establishing the relationship between elastic bond constants and measurable parameters, i.e., Poisson's ratio ν and systematic elastic constant K. At the atomistic level, this approach is within the framework of linear elastic theory and encompasses the neighbor interactions when an atom is introduced to stress. Departing from the force equilibrium equations, the relationships between ν, K, and spring constants are successfully established. Both the two-dimensional (2D) square lattice and common three-dimensional (3D) structures are taken into account in the procedure for facilitating, bridging the gap between structural complexity and numerical experiments. A new direction for understanding the physical phenomena in strain engineering is established.

  2. A nonlocal approach to the cosmological constant problem

    Science.gov (United States)

    Carroll, Sean M.; Remmen, Grant N.

    2017-06-01

    We construct a model in which the cosmological constant is canceled from the gravitational equations of motion. Our model relies on two key ingredients: a nonlocal constraint on the action, which forces the spacetime average of the Lagrangian density to vanish, and a dynamical way for this condition to be satisfied classically with arbitrary matter content. We implement the former condition with a spatially constant Lagrange multiplier associated with the volume form and the latter by including a free four-form gauge field strength in the action. These two features are enough to remove the cosmological constant from the Einstein equation. The model is consistent with all cosmological and experimental bounds on modification of gravity and allows for both cosmic inflation and the present epoch of acceleration.

  3. Dispersion Forces

    CERN Document Server

    Buhmann, Stefan Yoshi

    2012-01-01

    In this book, a modern unified theory of dispersion forces on atoms and bodies is presented which covers a broad range of advanced aspects and scenarios. Macroscopic quantum electrodynamics is shown to provide a powerful framework for dispersion forces which allows for discussing general properties like their non-additivity and the relation between microscopic and macroscopic interactions. It is demonstrated how the general results can be used to obtain dispersion forces on atoms in the presence of bodies of various shapes and materials. Starting with a brief recapitulation of volume I, this volume II deals especially with bodies of irregular shapes, universal scaling laws, dynamical forces on excited atoms, enhanced forces in cavity quantum electrodynamics, non-equilibrium forces in thermal environments and quantum friction. The book gives both the specialist and those new to the field a thorough overview over recent results in the field. It provides a toolbox for studying dispersion forces in various contex...

  4. Beta1 integrin inhibits apoptosis induced by cyclic stretch in annulus fibrosus cells via ERK1/2 MAPK pathway.

    Science.gov (United States)

    Zhang, Kai; Ding, Wei; Sun, Wei; Sun, Xiao-jiang; Xie, You-zhuan; Zhao, Chang-qing; Zhao, Jie

    2016-01-01

    Low back pain is associated with intervertebral disc degeneration (IVDD) due to cellular loss through apoptosis. Mechanical factors play an important role in maintaining the survival of the annulus fibrosus (AF) cells and the deposition of extracellular matrix. However, the mechanisms that excessive mechanical forces lead to AF cell apoptosis are not clear. The present study was to look for how AF cells sense mechanical changes. In vivo experiments, the involvement of mechanoreceptors in apoptosis was examined by RT-PCR and/or immunoblotting in the lumbar spine of rats subjected to unbalanced dynamic and static forces. In vitro experiments, we investigated apoptotic signaling pathways in untransfected and transfected AF cells with the lentivirus vector for rat β1 integrin overexpression after cyclic stretch. Apoptosis in AF cells was assessed using flow cytometry, Hoechst 33258 nuclear staining. Western blotting was used to analyze expression of β1 integrin and caspase-3 and ERK1/2 MAPK signaling molecules. In the rat IVDD model, unbalanced dynamic and static forces induced apoptosis of disc cells, which corresponded to decreased expression of β1 integrin. Cyclic stretch-induced apoptosis in rat AF cells correlated with the activation of caspase-3 and with decreased levels of β1 integrin and the phosphorylation levels of ERK1/2 activation level. However, the overexpression of β1 integrin in AF cells ameliorated cyclic stretch-induced apoptosis and decreased caspase-3 activation. Furthermore, ERK1/2-specific inhibitor promotes apoptosis in vector β1-infected AF cells. These results suggest that the disruption of β1 integrin signaling may underlie disc cell apoptosis induced by mechanical stress. Further work is necessary to fully elucidate the pathophysiological mechanisms that underlie IVDD caused by unbalanced dynamic and static forces.

  5. Stretching to prevent or reduce muscle soreness after exercise.

    Science.gov (United States)

    Herbert, Robert D; de Noronha, Marcos; Kamper, Steven J

    2011-07-06

    Many people stretch before or after engaging in athletic activity. Usually the purpose is to reduce risk of injury, reduce soreness after exercise, or enhance athletic performance. This is an update of a Cochrane review first published in 2007. The aim of this review was to determine effects of stretching before or after exercise on the development of delayed-onset muscle soreness. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register (to 10 August 2009), the Cochrane Central Register of Controlled Trials (2010, Issue 1), MEDLINE (1966 to 8th February 2010), EMBASE (1988 to 8th February 2010), CINAHL (1982 to 23rd February 2010), SPORTDiscus (1949 to 8th February 2010), PEDro (to 15th February 2010) and reference lists of articles. Eligible studies were randomised or quasi-randomised studies of any pre-exercise or post-exercise stretching technique designed to prevent or treat delayed-onset muscle soreness (DOMS). For the studies to be included, the stretching had to be conducted soon before or soon after exercise and muscle soreness had to be assessed. Risk of bias was assessed using The Cochrane Collaboration's 'Risk of bias' tool and quality of evidence was assessed using GRADE. Estimates of effects of stretching were converted to a common 100-point scale. Outcomes were pooled in fixed-effect meta-analyses. Twelve studies were included in the review. This update incorporated two new studies. One of the new trials was a large field-based trial that included 2377 participants, 1220 of whom were allocated stretching. All other 11 studies were small, with between 10 and 30 participants receiving the stretch condition. Ten studies were laboratory-based and other two were field-based. All studies were exposed to either a moderate or high risk of bias. The quality of evidence was low to moderate.There was a high degree of consistency of results across studies. The pooled estimate showed that pre-exercise stretching reduced soreness at one

  6. Thermal Radiation Effects on MHD with Flow Heat and Mass Transfer in Casson Nanofluid over A Stretching Sheet

    Directory of Open Access Journals (Sweden)

    Kho Yap Bing

    2018-01-01

    Full Text Available The boundary layer heat and mass transfer flow of Casson nanofluid over a stretching sheet with constant wall temperature (CWT under the magnetic field and thermal radiation effects is investigated numerically. Using similarity transformations, the governing equations are reduced to a set of nonlinear ordinary differential equations (ODEs. These equations are solved numerically by Shooting method. The effects of Casson parameter, magnetic parameter, porosity parameter, radiation parameter, Prandtl number, Brownian parameter and thermophoresis parameter on velocity, temperature and concentration fields are shown graphically and discussed. The results show that increase in Casson parameter causes the wall temperature increase well in the nanofluid.

  7. Effects on hamstring muscle extensibility, muscle activity, and balance of different stretching techniques.

    Science.gov (United States)

    Lim, Kyoung-Il; Nam, Hyung-Chun; Jung, Kyoung-Sim

    2014-02-01

    [Purpose] The purpose of this study was to investigate the effects of two different stretching techniques on range of motion (ROM), muscle activation, and balance. [Subjects] For the present study, 48 adults with hamstring muscle tightness were recruited and randomly divided into three groups: a static stretching group (n=16), a PNF stretching group (n=16), a control group (n=16). [Methods] Both of the stretching techniques were applied to the hamstring once. Active knee extension angle, muscle activation during maximum voluntary isometric contraction (MVC), and static balance were measured before and after the application of each stretching technique. [Results] Both the static stretching and the PNF stretching groups showed significant increases in knee extension angle compared to the control group. However, there were no significant differences in muscle activation or balance between the groups. [Conclusion] Static stretching and PNF stretching techniques improved ROM without decrease in muscle activation, but neither of them exerted statistically significant effects on balance.

  8. Charm production and the confining force field

    International Nuclear Information System (INIS)

    Andersson, B.; Bengtsson, H.-U.; Gustafson, G.

    1983-03-01

    We show that charm production at SPS energies can be understood simply from O(α 2 sub (s)) QCD processes when combined with fragmentation of the colour fields stretched by the final state partons. The tension of the confining force field responsible for particle production is found to pull the charmed particles away from the reaction centre, giving rise to a harder x sub (F)-spectrum than would be expected from the bare QCD matrix elements. (Authors)

  9. MEASUREMENT OF TEXTURAL PROPERTIES OF FOODS WITH A CONSTANT SPEED CONE PENETROMETER.

    Science.gov (United States)

    Tanaka, M; DE Man, J M; Voisey, P W

    1971-09-01

    A constant speed cone penetrometer was used to measure textural properties of a variety of foods. Apparent viscosity and yield value were calculated from the recorded relationships of penetrating force and depth. Good agreement was found between yield values determined by this method and those obtained with a constant weight cone penetrometer.

  10. Stretching and controlled motion of single-stranded DNA in locally heated solid-state nanopores.

    Science.gov (United States)

    Belkin, Maxim; Maffeo, Christopher; Wells, David B; Aksimentiev, Aleksei

    2013-08-27

    Practical applications of solid-state nanopores for DNA detection and sequencing require the electrophoretic motion of DNA through the nanopores to be precisely controlled. Controlling the motion of single-stranded DNA presents a particular challenge, in part because of the multitude of conformations that a DNA strand can adopt in a nanopore. Through continuum, coarse-grained and atomistic modeling, we demonstrate that local heating of the nanopore volume can be used to alter the electrophoretic mobility and conformation of single-stranded DNA. In the nanopore systems considered, the temperature near the nanopore is modulated via a nanometer-size heater element that can be radiatively switched on and off. The local enhancement of temperature produces considerable stretching of the DNA fragment confined within the nanopore. Such stretching is reversible, so that the conformation of DNA can be toggled between compact (local heating is off) and extended (local heating is on) states. The effective thermophoretic force acting on single-stranded DNA in the vicinity of the nanopore is found to be sufficiently large (4-8 pN) to affect such changes in the DNA conformation. The local heating of the nanopore volume is observed to promote single-file translocation of DNA strands at transmembrane biases as low as 10 mV, which opens new avenues for using solid-state nanopores for detection and sequencing of DNA.

  11. Triceps surae short latency stretch reflexes contribute to ankle stiffness regulation during human running.

    Directory of Open Access Journals (Sweden)

    Neil J Cronin

    Full Text Available During human running, short latency stretch reflexes (SLRs are elicited in the triceps surae muscles, but the function of these responses is still a matter of controversy. As the SLR is primarily mediated by Ia afferent nerve fibres, various methods have been used to examine SLR function by selectively blocking the Ia pathway in seated, standing and walking paradigms, but stretch reflex function has not been examined in detail during running. The purpose of this study was to examine triceps surae SLR function at different running speeds using Achilles tendon vibration to modify SLR size. Ten healthy participants ran on an instrumented treadmill at speeds between 7 and 15 km/h under 2 Achilles tendon vibration conditions: no vibration and 90 Hz vibration. Surface EMG from the triceps surae and tibialis anterior muscles, and 3D lower limb kinematics and ground reaction forces were simultaneously collected. In response to vibration, the SLR was depressed in the triceps surae muscles at all speeds. This coincided with short-lasting yielding at the ankle joint at speeds between 7 and 12 km/h, suggesting that the SLR contributes to muscle stiffness regulation by minimising ankle yielding during the early contact phase of running. Furthermore, at the fastest speed of 15 km/h, the SLR was still depressed by vibration in all muscles but yielding was no longer evident. This finding suggests that the SLR has greater functional importance at slow to intermediate running speeds than at faster speeds.

  12. Effect of homogenous-heterogeneous reactions on MHD Prandtl fluid flow over a stretching sheet

    Directory of Open Access Journals (Sweden)

    Imad Khan

    Full Text Available An analysis is performed to explore the effects of homogenous-heterogeneous reactions on two-dimensional flow of Prandtl fluid over a stretching sheet. In present analysis, we used the developed model of homogeneous–heterogeneous reactions in boundary layer flow. The mathematical configuration of presented flow phenomenon yields the nonlinear partial differential equations. Using scaling transformations, the governing partial differential equations (momentum equation and homogenous-heterogeneous reactions equations are transformed into non-linear ordinary differential equations (ODE’s. Then, resulting non-linear ODE’s are solved by computational scheme known as shooting method. The quantitative and qualitative manners of concerned physical quantities (velocity, concentration and drag force coefficient are examined under prescribed physical constrained through figures and tables. It is observed that velocity profile enhances verses fluid parameters α and β while Hartmann number reduced it. The homogeneous and heterogeneous reactions parameters have reverse effects on concentration profile. Concentration profile shows retarding behavior for large values of Schmidt number. Skin fraction coefficient enhances with increment in Hartmann number H and fluid parameter α. Keywords: Prandtl fluid, Homogeneous-heterogeneous reactions, Stretching sheet, MHD

  13. Medial gastrocnemius muscle stiffness cannot explain the increased ankle joint range of motion following passive stretching in children with cerebral palsy.

    Science.gov (United States)

    Kalkman, Barbara M; Bar-On, Lynn; Cenni, Francesco; Maganaris, Constantinos N; Bass, Alfie; Holmes, Gill; Desloovere, Kaat; Barton, Gabor J; O'Brien, Thomas D

    2018-03-01

    What is the central question of this study? Can the increased range of motion seen acutely after stretching in children with cerebral palsy be explained by changes in the stiffness of the medial gastrocnemius fascicles? What is the main finding and its importance? We show, for the first time, that passive muscle and tendon properties are not changed acutely after a single bout of stretching in children with cerebral palsy and, therefore, do not contribute to the increase in range of motion. This contradicts common belief and what happens in healthy adults. Stretching is often used to increase or maintain the joint range of motion (ROM) in children with cerebral palsy (CP), but the effectiveness of these interventions is limited. Therefore, our aim was to determine the acute changes in muscle-tendon lengthening properties that contribute to increased ROM after a bout of stretching in children with CP. Eleven children with spastic CP [age 12.1 (3 SD) years, 5/6 hemiplegia/diplegia, 7/4 gross motor function classification system level I/II] participated. Each child received three sets of five × 20 s passive, manual static dorsiflexion stretches separated by 30 s rest, with 60 s rest between sets. Before and immediately after stretching, ultrasound was used to measure medial gastrocnemius fascicle lengthening continuously over the full ROM and an individual common ROM pre- to post-stretching. Simultaneously, three-dimensional motion of two marker clusters on the shank and the foot was captured to calculate ankle angle, and ankle joint torque was calculated from manually applied torques and forces on a six degrees-of-freedom load cell. After stretching, the ROM was increased [by 9.9 (12.0) deg, P = 0.005]. Over a ROM common to both pre- and post-measurements, there were no changes in fascicle lengthening or torque. The maximal ankle joint torque tolerated by the participants increased [by 2.9 (2.4) N m, P = 0.003], and at this highest passive torque the

  14. Arrhenius Rate: constant volume burn

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-12-06

    A constant volume burn occurs for an idealized initial state in which a large volume of reactants at rest is suddenly raised to a high temperature and begins to burn. Due to the uniform spatial state, there is no fluid motion and no heat conduction. This reduces the time evolu tion to an ODE for the reaction progress variable. With an Arrhenius reaction rate, two characteristics of thermal ignition are illustrated: induction time and thermal runaway. The Frank-Kamenetskii approximation then leads to a simple expression for the adiabatic induction time. For a first order reaction, the analytic solution is derived and used to illustrate the effect of varying the activation temperature; in particular, on the induction time. In general, the ODE can be solved numerically. This is used to illustrate the effect of varying the reaction order. We note that for a first order reaction, the time evolution of the reaction progress variable has an exponential tail. In contrast, for a reaction order less than one, the reaction completes in a nite time. The reaction order also affects the induction time.

  15. Stretching Local Dollars: A Small Town Guide to Matching Funds.

    Science.gov (United States)

    Brown, Hamilton

    The purpose of this guidebook is to help elected leaders of small towns and communities stretch their investments when matching funds are required to compete for a grant or to pay for development costs above the grant award itself. The federal "small cities" Community Development Block Grant (CDBG) is used as an example throughout the…

  16. On zero variance Monte Carlo path-stretching schemes

    International Nuclear Information System (INIS)

    Lux, I.

    1983-01-01

    A zero variance path-stretching biasing scheme proposed for a special case by Dwivedi is derived in full generality. The procedure turns out to be the generalization of the exponential transform. It is shown that the biased game can be interpreted as an analog simulation procedure, thus saving some computational effort in comparison with the corresponding nonanalog game

  17. Mediators of Yoga and Stretching for Chronic Low Back Pain

    Directory of Open Access Journals (Sweden)

    Karen J. Sherman

    2013-01-01

    Full Text Available Although yoga is an effective treatment for chronic low back pain, little is known about the mechanisms responsible for its benefits. In a trial comparing yoga to intensive stretching and self-care, we explored whether physical (hours of back exercise/week, cognitive (fear avoidance, body awareness, and self-efficacy, affective (psychological distress, perceived stress, positive states of mind, and sleep, and physiological factors (cortisol, DHEA mediated the effects of yoga or stretching on back-related dysfunction (Roland-Morris Disability Scale (RDQ. For yoga, 36% of the effect on 12-week RDQ was mediated by increased self-efficacy, 18% by sleep disturbance, 9% by hours of back exercise, and 61% by the best combination of all possible mediators (6 mediators. For stretching, 23% of the effect was mediated by increased self-efficacy, 14% by days of back exercise, and 50% by the best combination of all possible mediators (7 mediators. In open-ended questions, ≥20% of participants noted the following treatment benefits: learning new exercises (both groups, relaxation, increased awareness, and the benefits of breathing (yoga, benefits of regular practice (stretching. Although both self-efficacy and hours of back exercise were the strongest mediators for each intervention, compared to self-care, qualitative data suggest that they may exert their benefits through partially distinct mechanisms.

  18. Entropy generation in MHD flow of a uniformly stretched vertical ...

    African Journals Online (AJOL)

    This paper reports the analytical calculation of the entropy generation due to heat and mass transfer and fluid friction in steady state of a uniformly stretched vertical permeable surface with heat and mass diffusive walls, by solving analytically the mass, momentum, species concentration and energy balance equation, using ...

  19. Anharmonic bend-stretch coupling in neat liquid water

    NARCIS (Netherlands)

    Lindner, Joerg; Cringus, Dan; Pshenichnikov, Maxim S.; Voehringer, Peter

    2007-01-01

    Femtosecond mid-IR spectroscopy is used to study the vibrational relaxation dynamics in neat liquid water. By exciting the bending vibration and probing the stretching mode, it is possible to reliably determine the bending and librational lifetimes of water. The anharmonic coupling between the

  20. Effect of Mechanical Stretching of the Skin on Collagen Fibril ...

    African Journals Online (AJOL)

    Stabilization of collagen fibres during development and through growth to maturation has now become fairly documented. In vitro effect of mechanical stretching of ratsf skin on oxidative deamination of ε-NH2-groups of lysine and hydroxylysine, and functional properties of its type . collagen were studied. Experiments were ...

  1. Effects of Warm-Up Stretching Exercises on Sprint Performance

    Science.gov (United States)

    Makaruk, Hubert; Makaruk, Beata; Kedra, Stanislaw

    2008-01-01

    Study aim: To assess direct effects of warm-up consisting of static and dynamic stretching exercises on sprint results attained by students differing in sprint performance. Material and methods: A group of 24 male and 19 female physical education students, including 12 and 9 sprinters, respectively. They performed warm-ups consisting of dynamic…

  2. A Japanese Stretching Intervention Can Modify Lumbar Lordosis Curvature

    NARCIS (Netherlands)

    Kadono, Norio; Tsuchiya, Kazushi; Uematsu, Azusa; Kamoshita, Hiroshi; Kiryu, Kazunori; Hortobagyi, Tibor; Suzuki, Shuji

    Study Design: Eighteen healthy male adults were assigned to either an intervention or control group. Objectives: Isogai dynamic therapy (IDT) is one of Japanese stretching interventions and has been practiced for over 70 years. However, its scientific quantitative evidence remains unestablished. The

  3. Flow of viscous fluid along an exponentially stretching curved surface

    Directory of Open Access Journals (Sweden)

    N.F. Okechi

    Full Text Available In this paper, we present the boundary layer analysis of flow induced by rapidly stretching curved surface with exponential velocity. The governing boundary value problem is reduced into self-similar form using a new similarity transformation. The resulting equations are solved numerically using shooting and Runge-Kutta methods. The numerical results depicts that the fluid velocity as well as the skin friction coefficient increases with the surface curvature, similar trend is also observed for the pressure. The dimensionless wall shear stress defined for this problem is greater than that of a linearly stretching curved surface, but becomes comparably less for a surface stretching with a power-law velocity. In addition, the result for the plane surface is a special case of this study when the radius of curvature of the surface is sufficiently large. The numerical investigations presented in terms of the graphs are interpreted with the help of underlying physics of the fluid flow and the consequences arising from the curved geometry. Keywords: Boundary layer flow, Curved surface, Exponential stretching, Curvature

  4. Vibrations of stretched damped beams under non-ideal boundary ...

    Indian Academy of Sciences (India)

    Stretched beam vibrations; non-ideal boundary conditions; method of multiple time scales. 1. Introduction. Beams are frequently used as design models for vibration analysis. In such analysis, types of support conditions are important and have direct effect on the solutions and natural fre- quencies. Different types of supports ...

  5. Stretch Intensity vs. Inflammation: A Dose-dependent Association?

    Directory of Open Access Journals (Sweden)

    Nikos Apostolopoulos BPHE

    2015-01-01

    Full Text Available The intensity of stretching is rarely reported in scientific literature. In this study, we examined the effects of stretching intensities at 30%, 60%, and 90% of maximum range of movement (mROM on the inflammatory response of the right hamstring muscle. Methods: A randomised within-subject trial was conducted with 11 healthy recreationally active males over a three week period. Participants were strapped into an isokinetic dynamometer in the supine position, with the right knee fastened in a knee immobilizer. After randomising the ROM percentages, the hamstring muscle was moved to one of the three chosen ROM percentages for that week and held there for 5 x 60 seconds followed by a 10 second rest between repetitions. A 5ml blood sample was collected pre-, immediately post, and at 24 hours post intervention for high sensitivity C-reactive protein (hsCRP assessments. Results: Significant increases in hsCRP levels were observed between 30% mROM and 90% mROM (p=0.004 and 60% mROM and 90% mROM (p=0.034, but not between 30% and 60% (p>0.05. Conclusions: Muscle stretching at submaximal levels does not elicit a significant systemic inflammatory responses. Keywords: Stretch intensity, inflammation, hsCRP

  6. MHD flow of a uniformly stretched vertical permeable membrane in ...

    African Journals Online (AJOL)

    Journal of the Nigerian Association of Mathematical Physics ... Abstract. We present a magneto - hydrodynamic flow of a uniformly stretched vertical permeable surface undergoing Arrhenius heat reaction. ... It is also established that maximum velocity occurs in the body of the fluid close to the surface and not the surface.

  7. Contact of a spherical probe with a stretched rubber substrate

    Science.gov (United States)

    Frétigny, Christian; Chateauminois, Antoine

    2017-07-01

    We report on a theoretical and experimental investigation of the normal contact of stretched neo-Hookean substrates with rigid spherical probes. Starting from a published formulation of surface Green's function for incremental displacements on a prestretched, neo-Hookean, substrate [J. Mech. Phys. Solids 56, 2957 (2008), 10.1016/j.jmps.2008.07.002], a model is derived for both adhesive and nonadhesive contacts. The shape of the elliptical contact area together with the contact load and the contact stiffness are predicted as a function of the in-plane stretch ratios λx and λy of the substrate. The validity of this model is assessed by contact experiments carried out using an uniaxally stretched silicone rubber. For stretch ratio below about 1.25, a good agreement is observed between theory and experiments. Above this threshold, some deviations from the theoretical predictions are induced as a result of the departure of the mechanical response of the silicone rubber from the neo-Hokeean description embedded in the model.

  8. Effect of Mechanical Stretching of the Skin on Collagen Fibril ...

    African Journals Online (AJOL)

    Dell

    It was recently established that, deformation of connective tissue cells under the influence of mechanical stretching intensifies the synthesis of structural biopolymers, particularly those of the collagen molecules, which are capable of associating into fibrils by self assembly (Buschmann et al., 1995,. Garbuzenko et al., 1997; ...

  9. Bruxism: Is There an Indication for Muscle-Stretching Exercises?

    NARCIS (Netherlands)

    Gouw, S.; Wijer, A. de; Creugers, N.H.J.; Kalaykova, S.I.

    2017-01-01

    Bruxism is a common phenomenon involving repetitive activation of the masticatory muscles. Muscle-stretching exercises are a recommended part of several international guidelines for musculoskeletal disorders and may be effective in management of the jaw muscle activity that gives rise to bruxism.

  10. Sport stretching : Effect on passive muscle stiffness of short hamstrings

    NARCIS (Netherlands)

    Halbertsma, JPK; vanBolhuis, AI; Goeken, LNH

    Objective: To evaluate the effects of one 10-minute stretch on muscle stiffness in subjects with short hamstrings. Design: Randomized control trial. Setting: Laboratory for human movement sciences in the department of rehabilitation of a university hospital. Subjects: Sixteen students from the

  11. The health of benthic diatom assemblages in lower stretch

    Indian Academy of Sciences (India)

    This study examines the ecological state of epilithic diatom assemblages along the lower stretch of Mandakini, a glacier-fed Himalayan river. The diatoms were sampled at four stations during winter and summer, only once in each season. Valve counts were obtained from Naphrax mounts prepared from each sample.

  12. A single molecule DNA flow stretching microscope for undergraduates

    NARCIS (Netherlands)

    Williams, Kelly; Grafe, Brendan; Burke, Kathryn M.; Tanner, Nathan; van Oijen, Antoine M.; Loparo, Joseph; Price, Allen C.

    2011-01-01

    The design of a simple, safe, and inexpensive single molecule flow stretching instrument is presented. The instrument uses a low cost upright microscope coupled to a webcam for imaging single DNA molecules that are tethered in an easy to construct microfluidic flow cell. The system requires no

  13. Acute effects of active isolated stretching on vertical jump ...

    African Journals Online (AJOL)

    The purpose of the study was to determine the acute effects of active isolated stretching on muscular peak power production. Sixty healthy, physically active volunteers (aged 18-28) participated as subjects in this study. Subjects were randomly assigned to two groups; the control group and the experimental group. Subjects ...

  14. Cooperativity among short amyloid stretches in long amyloidogenic sequences.

    Directory of Open Access Journals (Sweden)

    Lele Hu

    Full Text Available Amyloid fibrillar aggregates of polypeptides are associated with many neurodegenerative diseases. Short peptide segments in protein sequences may trigger aggregation. Identifying these stretches and examining their behavior in longer protein segments is critical for understanding these diseases and obtaining potential therapies. In this study, we combined machine learning and structure-based energy evaluation to examine and predict amyloidogenic segments. Our feature selection method discovered that windows consisting of long amino acid segments of ~30 residues, instead of the commonly used short hexapeptides, provided the highest accuracy. Weighted contributions of an amino acid at each position in a 27 residue window revealed three cooperative regions of short stretch, resemble the β-strand-turn-β-strand motif in A-βpeptide amyloid and β-solenoid structure of HET-s(218-289 prion (C. Using an in-house energy evaluation algorithm, the interaction energy between two short stretches in long segment is computed and incorporated as an additional feature. The algorithm successfully predicted and classified amyloid segments with an overall accuracy of 75%. Our study revealed that genome-wide amyloid segments are not only dependent on short high propensity stretches, but also on nearby residues.

  15. Gene expression of stretch-activated channels and mechanoelectric feedback in the heart.

    Science.gov (United States)

    Kelly, D; Mackenzie, L; Hunter, P; Smaill, B; Saint, D A

    2006-07-01

    1. Mechanoelectric feedback (MEF) in the heart is the process by which mechanical forces on the myocardium can change its electrical properties. Mechanoelectric feedback has been demonstrated in many animal models, ranging from isolated cells, through isolated hearts to whole animals. In humans, MEF has been demonstrated directly in both the atria and the ventricles. It seems likely that MEF provides either the trigger or the substrate for some types of clinically important arrhythmias. 2. Mechanoelectric feedback may arise because of the presence of stretch-sensitive (or mechano-sensitive) ion channels in the cell membrane of the cardiac myocytes. Two types have been demonstrated: (i) a non-specific cation channel (stretch-activated channel (SAC); conductance of approximately 25 pS); and (ii) a potassium channel with a conductance of approximately 100 pS. The gene coding for the SAC has not yet been identified. The gene for the potassium channel is likely to be TREK, a member of the tandem pore potassium channel gene family. We have recorded stretch-sensitive potassium channels in rat isolated myocytes that have the properties of TREK channels expressed in heterologous systems. 3. It has been shown that TREK mRNA is expressed heterogeneously in the rat ventricular wall, with 17-fold more expression in endocardial compared with epicardial cells. This difference is reflected in the TREK currents recorded from endocardial and epicardial cells using whole-cell patch-clamp techniques, although the difference in current density was less pronounced (approximately threefold). Consistent with this, we show here that when the ventricle is stretched by inflation of an intraventricular balloon in a Langendorff perfused rat isolated heart, action potential shortening was more pronounced in the endocardium (30% shortening at 40 mmHg) compared with that in the epicardium (10% shortening at the same pressure). 4. Computer models of the mechanics of the (pig) heart show pronounced

  16. Stretching skeletal muscle: chronic muscle lengthening through sarcomerogenesis.

    Directory of Open Access Journals (Sweden)

    Alexander M Zöllner

    Full Text Available Skeletal muscle responds to passive overstretch through sarcomerogenesis, the creation and serial deposition of new sarcomere units. Sarcomerogenesis is critical to muscle function: It gradually re-positions the muscle back into its optimal operating regime. Animal models of immobilization, limb lengthening, and tendon transfer have provided significant insight into muscle adaptation in vivo. Yet, to date, there is no mathematical model that allows us to predict how skeletal muscle adapts to mechanical stretch in silico. Here we propose a novel mechanistic model for chronic longitudinal muscle growth in response to passive mechanical stretch. We characterize growth through a single scalar-valued internal variable, the serial sarcomere number. Sarcomerogenesis, the evolution of this variable, is driven by the elastic mechanical stretch. To analyze realistic three-dimensional muscle geometries, we embed our model into a nonlinear finite element framework. In a chronic limb lengthening study with a muscle stretch of 1.14, the model predicts an acute sarcomere lengthening from 3.09[Formula: see text]m to 3.51[Formula: see text]m, and a chronic gradual return to the initial sarcomere length within two weeks. Compared to the experiment, the acute model error was 0.00% by design of the model; the chronic model error was 2.13%, which lies within the rage of the experimental standard deviation. Our model explains, from a mechanistic point of view, why gradual multi-step muscle lengthening is less invasive than single-step lengthening. It also explains regional variations in sarcomere length, shorter close to and longer away from the muscle-tendon interface. Once calibrated with a richer data set, our model may help surgeons to prevent muscle overstretch and make informed decisions about optimal stretch increments, stretch timing, and stretch amplitudes. We anticipate our study to open new avenues in orthopedic and reconstructive surgery and enhance

  17. Method for lateral force calibration in atomic force microscope using MEMS microforce sensor.

    Science.gov (United States)

    Dziekoński, Cezary; Dera, Wojciech; Jarząbek, Dariusz M

    2017-11-01

    In this paper we present a simple and direct method for the lateral force calibration constant determination. Our procedure does not require any knowledge about material or geometrical parameters of an investigated cantilever. We apply a commercially available microforce sensor with advanced electronics for direct measurement of the friction force applied by the cantilever's tip to a flat surface of the microforce sensor measuring beam. Due to the third law of dynamics, the friction force of the equal value tilts the AFM cantilever. Therefore, torsional (lateral force) signal is compared with the signal from the microforce sensor and the lateral force calibration constant is determined. The method is easy to perform and could be widely used for the lateral force calibration constant determination in many types of atomic force microscopes. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Wrinkling instability of an inhomogeneously stretched viscous sheet

    Science.gov (United States)

    Srinivasan, Siddarth; Wei, Zhiyan; Mahadevan, L.

    2017-07-01

    Motivated by the redrawing of hot glass into thin sheets, we investigate the shape and stability of a thin viscous sheet that is inhomogeneously stretched in an imposed nonuniform temperature field. We first determine the associated base flow by solving the long-time-scale stretching flow of a flat sheet as a function of two dimensionless parameters: the normalized stretching velocity α and a dimensionless width of the heating zone β . This allows us to determine the conditions for the onset of an out-of-plane wrinkling instability stated in terms of an eigenvalue problem for a linear partial differential equation governing the displacement of the midsurface of the sheet. We show that the sheet can become unstable in two regions that are upstream and downstream of the heating zone where the minimum in-plane stress is negative. This yields the shape and growth rates of the most unstable buckling mode in both regions for various values of the stretching velocity and heating zone width. A transition from stationary to oscillatory unstable modes is found in the upstream region with increasing β , while the downstream region is always stationary. We show that the wrinkling instability can be entirely suppressed when the surface tension is large enough relative to the magnitude of the in-plane stress. Finally, we present an operating diagram that indicates regions of the parameter space that result in a required outlet sheet thickness upon stretching while simultaneously minimizing or suppressing the out-of-plane buckling, a result that is relevant for the glass redraw method used to create ultrathin glass sheets.

  19. Forced marriage.

    Science.gov (United States)

    2007-06-01

    Guidelines to help A&E staff and other healthcare professionals who suspect cases of forced marriage were launched this month by the government. The guidelines provide practical advice on how to recognise the warning signs, and what to do if patients disclose that they have been, or are about to be, forced to marry. The guidelines, Dealing with Cases of Forced Marriage, are available at www.fco.gov.uk/forcedmarriage.

  20. ESR melting under constant voltage conditions

    Energy Technology Data Exchange (ETDEWEB)

    Schlienger, M.E.

    1997-02-01

    Typical industrial ESR melting practice includes operation at a constant current. This constant current operation is achieved through the use of a power supply whose output provides this constant current characteristic. Analysis of this melting mode indicates that the ESR process under conditions of constant current is inherently unstable. Analysis also indicates that ESR melting under the condition of a constant applied voltage yields a process which is inherently stable. This paper reviews the process stability arguments for both constant current and constant voltage operation. Explanations are given as to why there is a difference between the two modes of operation. Finally, constant voltage process considerations such as melt rate control, response to electrode anomalies and impact on solidification will be discussed.