  1. Transducers for Sound and Vibration - FEM Based Design

    DEFF Research Database (Denmark)

    Liu, Bin

    2001-01-01

    Design of transducers for measurement of vibration (piezoelectric accelerometers) and sound (condenser microphones) is a very labour intensive work. The design work is mostly based on experience and on simple analogies to electrical circuit design. Often a time consuming itterative loop is used......: Specification of the transducer, production of a physical prototype, measurements on the prototype, changed specification of the transducer etc. Furthermore are many transducers made based on customer requirements which also increases the amount of required design work. For these reasons there is a need...

  2. Design optimization of embedded ultrasonic transducers for concrete structures assessment.

    Science.gov (United States)

    Dumoulin, Cédric; Deraemaeker, Arnaud

    2017-08-01

    In the last decades, the field of structural health monitoring and damage detection has been intensively explored. Active vibration techniques allow to excite structures at high frequency vibrations which are sensitive to small damage. Piezoelectric PZT transducers are perfect candidates for such testing due to their small size, low cost and large bandwidth. Current ultrasonic systems are based on external piezoelectric transducers which need to be placed on two faces of the concrete specimen. The limited accessibility of in-service structures makes such an arrangement often impractical. An alternative is to embed permanently low-cost transducers inside the structure. Such types of transducers have been applied successfully for the in-situ estimation of the P-wave velocity in fresh concrete, and for crack monitoring. Up to now, the design of such transducers was essentially based on trial and error, or in a few cases, on the limitation of the acoustic impedance mismatch between the PZT and concrete. In the present study, we explore the working principles of embedded piezoelectric transducers which are found to be significantly different from external transducers. One of the major challenges concerning embedded transducers is to produce very low cost transducers. We show that a practical way to achieve this imperative is to consider the radial mode of actuation of bulk PZT elements. This is done by developing a simple finite element model of a piezoelectric transducer embedded in an infinite medium. The model is coupled with a multi-objective genetic algorithm which is used to design specific ultrasonic embedded transducers both for hard and fresh concrete monitoring. The results show the efficiency of the approach and a few designs are proposed which are optimal for hard concrete, fresh concrete, or both, in a given frequency band of interest. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Design and Development of a Pressure Transducer for High Hydrostatic Pressure Measurements up to 200 MPa

    Science.gov (United States)

    Kumar, Anuj; Yadav, Sanjay; Agarwal, Ravinder

    2017-08-01

    A number of pressure transducers, based on strain gauge, capacitance/inductance type, frequency resonators, are commercially available and are being used for sensing and producing an electrical output proportional to applied pressure. These sensors have their own advantages and limitations due to operational ease, measurement uncertainty and the costs. Strain gauge type transducers are now well established devices for accurate and precise measurement of pressure within measurement uncertainty up to 0.1 % of full scale. In the present research work, an indigenous strain gauge pressure transducer has been designed, developed, tested and calibrated for pressure measurement up to 200 MPa. The measurement uncertainty estimated using the pressure transducer was found better than 0.1 % of full scale. This transducer was developed using four foil type strain gauges, bonded, two in axial direction while other two in radial direction, to the controlled stress zones of a tubular maraging steel active cylinder working also as diaphragm. The strain gages were then connected to a Wheatstone bridge arrangement to measure stress generated strains. The pressure was applied through matching connector designed in the same tubular transducer active element. The threaded unique design in a single piece through collar, ferule and tubing arrangement provides leak proof pressure connections with external devices without using additional seals. The calibration and performance checking of the pressure transducer was carried out using dead weight type national pressure standard using the internationally accepted calibration procedure.

  4. Experimental Evaluation of Three Designs of Electrodynamic Flexural Transducers.

    Science.gov (United States)

    Eriksson, Tobias J R; Laws, Michael; Kang, Lei; Fan, Yichao; Ramadas, Sivaram N; Dixon, Steve

    2016-08-25

    Three designs for electrodynamic flexural transducers (EDFT) for air-coupled ultrasonics are presented and compared. An all-metal housing was used for robustness, which makes the designs more suitable for industrial applications. The housing is designed such that there is a thin metal plate at the front, with a fundamental flexural vibration mode at ∼50 kHz. By using a flexural resonance mode, good coupling to the load medium was achieved without the use of matching layers. The front radiating plate is actuated electrodynamically by a spiral coil inside the transducer, which produces an induced magnetic field when an AC current is applied to it. The transducers operate without the use of piezoelectric materials, which can simplify manufacturing and prolong the lifetime of the transducers, as well as open up possibilities for high-temperature applications. The results show that different designs perform best for the generation and reception of ultrasound. All three designs produced large acoustic pressure outputs, with a recorded sound pressure level (SPL) above 120 dB at a 40 cm distance from the highest output transducer. The sensitivity of the transducers was low, however, with single shot signal-to-noise ratio ( SNR ) ≃ 15 dB in transmit-receive mode, with transmitter and receiver 40 cm apart.

  5. DESIGN AND IMPLEMENTATION OF POTENTIOMETER-BASED NONLINEAR TRANSDUCER EMULATOR

    Directory of Open Access Journals (Sweden)

    Sheroz Khan

    2011-05-01

    Full Text Available This work attempts to design and implement in hardware a transducer with a nonlinear response using potentiometer. Potentiometer is regarded as a linear transducer, while a the response of a nonlinear transducer can be treated as a concatenation of linear segments made out of the response curve of an actual nonlinear transducer at the points of inflections being exhibited by the nonlinear curve. Each straight line segment is characterized by its slope and a constant, called the y-intercept, which is ultimately realized by a corresponding electronic circuit. The complete circuit diagram is made of three stages: (i the input stage for range selection, (ii a digital logic to make appropriate selection, (iii a conditioning circuit for realizing a given straight-line segment identified by its relevant slope and reference voltage. The simulation of the circuit is carried using MULTISIM, and the designed circuit is afterward tested to verify that variations of the input voltage give us an output voltage very close to the response pattern envisaged in the analytical stage of the design. The utility of this work lies in its applications in emulating purpose built transducers that could be used to nicely emulate a transducer in a real world system that is to be controlled by a programmable digital system.

  6. Design and numerical simulation of novel giant magnetostrictive ultrasonic transducer

    Directory of Open Access Journals (Sweden)

    Pengyang Li

    Full Text Available This paper provides a design method of a novel giant magnetostrictive ultrasonic transducer utilized in incremental sheet metal forming. The frequency equations of the ultrasonic vibrator were deduced and the corresponding correctness verified by the modal and harmonic response characteristic through the finite element method (FEM and ANSYS software. In addition, the magnetic field of the vibrator system was designed and verified by the ANSYS. Finally, the frequency tests based on the impedance response analysis and the amplitude measurements based on the laser displacement sensor were performed on the prototype. The results confirmed the appropriate design of this transducer, setting the foundation for a low mechanical quality factor and satisfying amplitude. Keywords: Magnetostrictive, Incremental sheet forming, Ultrasonic transducer

  7. Frequency wavenumber design of spiral macro fiber composite directional transducers

    Science.gov (United States)

    Carrara, Matteo; Ruzzene, Massimo

    2015-04-01

    This work is focused on design and testing of a novel class of transducers for Structural Health Monitoring (SHM), able to perform directional interrogation of plate-like structures. These transducers leverage guided waves (GWs), and in particular Lamb waves, that have emerged as a very prominent option for assessing the state of a structure during operation. GW-SHM approaches greatly benefit from the use of transducers with controllable directional characteristics, so that selective scanning of a surface can be performed to locate damage, impacts, or cracks. In the concepts that we propose, continuous beam steering and directional actuation are achieved through proper selection of the excitation frequency. The design procedure takes advantage of the wavenumber representation of the device, and formulates the problem using a Fourier-based approach. The active layer of the transducer is made of piezoelectric fibers embedded into an epoxy matrix, allowing the device to be flexible, and thus suitable for application on non{ at surfaces. Proper shaping of the electrodes pattern through a compensation function allows taking into account the anisotropy level introduced by the active layer. The resulting spiral frequency steerable acoustic actuator is a configuration that features (i) enhanced performance, (ii) reduced complexity, and (iii) reduced hardware requirements of such devices.

  8. Accuracy of soil stress measurements as affected by transducer dimensions and shape

    DEFF Research Database (Denmark)

    Lamandé, Mathieu; Keller, Thomas; Berisso, Feto Esimo

    2015-01-01

    Accurate measurements of soil stress are needed to evaluate the impact of traffic on soil properties and prevent soil compaction. Four types of transducer commonly used to measure vertical stress were calibrated in realistic traffic conditions in the field. The four transducer types differed...... in shape and dimensions, which are important factors influencing stress. Deviation of measured stress from true stress ranged from 15% underestimation to 18% overestimation, with transducer thickness to width ratio being the most important shape factor influencing the stress recorded. Changes in physical...... conditions in the soil above the transducers due to their installation did not influence the accuracy of vertical stress measurements. The results of this calibration are valid for correcting stress measurements in topsoil, but should be used with caution for vertical stress measurements in subsoil. All...

  9. Influence of bending stress on domain motion in amorphous material based magneto-elastic transducers

    International Nuclear Information System (INIS)

    Meydan, T.; Goktepe, M.; Honda, A.; Derebasi, N.

    1992-01-01

    The investigation of the flux distribution in a toroidal core helps us understand the physical operating principle of magneto-elastic transducers. Application of force induces bending stresses on the devices. The influence of these stresses on the magnetic domain patterns were studied. The non-uniform flux distribution along the circumference of these transducer cores were reported

  10. Design and Testing of the Strain Transducer for Measuring Deformations of Pipelines Operating in the Mining-deformable Ground Environment

    Directory of Open Access Journals (Sweden)

    Gawedzki Waclaw

    2015-10-01

    Full Text Available Design and laboratory test results of the strain transducer intended for monitoring and assessing stress states of pipelines sited in mining areas are presented in this paper. This transducer allows measuring strains of pipelines subjected to external forces - being the mining operations effect. Pipeline strains can have a direct influence on a tightness loss and penetration of the transported fluid into the environment. The original strain gauge transducer was proposed for performing measurements of strains. It allows measuring circumferential strains and determining the value and direction of the main longitudinal strain. This strain is determined on the basis of measuring component longitudinal strains originating from axial forces and the resultant bending moment. The main purpose of investigations was the experimental verification of the possibility of applying the strain transducer for measuring strains of polyethylene pipelines. The obtained results of the transducer subjected to influences of tensile and compression forces are presented and tests of relaxation properties of polyethylene are performed.

  11. Reducing the Effect of Transducer Mount Induced Noise on Aeroacoustic Wind Tunnel Testing Data with a New Transducer Mount Design

    Science.gov (United States)

    Herron, A. J.; Reed, D. K.; Nance, D. K.

    2015-01-01

    Characterization of launch vehicle unsteady aerodynamics is a field best studied through experimentation, which is often carried out in the form of large scale wind tunnel testing. Measurement of the fluctuating pressures induced by the boundary layer noise is customarily made with miniature pressure transducers installed into a model of the vehicle of interest. Literature shows that noise level increases between two to five decibels (dB referenced to 20 micropascal) can be induced when the transducer surface is not mounted perfectly flush with the model outer surface. To reduce this artificially induced noise, special transducer holders have been used for aeroacoustic wind tunnel testing by NASA. This holder is a sleeve into which the transducer fits, with a cap that allows it to be mounted in a recessed hole in the model. A single hole in the holder allows the transport of the tunnel medium so the transducer can discriminate the fluctuating pressure due to the turbulent boundary layer noise. The holder is first dry fitted into the model and any difference in height between the holder and the model surface can be sanded flush. The holder is then removed from the model, the transducer glued inside the holder, and the holder replaced in the model, secured also with glue, thus eliminating the problem of noise level increases due to lack of flushness. In order to work with this holder design, special transducers have been ordered with their standard screen removed and the diaphragm moved as close to the top of the casing as possible to minimize any cavity volume. Although this greatly reduces induced noise due to the transducers being out of flush, the holders can also induce a cavity resonance that is usually at a very high frequency. This noise is termed transducer mount induced noise (XMIN). The peak of the mode can vary with the cavity depth, boundary layer noise that can excite the mode, tunnel flow medium, and the build of the transducers. Because the boundary

  12. Optimization of matching layer design for medical ultrasonic transducer

    Science.gov (United States)

    Zhu, Jie

    -microns in order to reduce wave scattering because the wavelength is much smaller. High volume loading fine powder composite is very difficult to make using conventional composite fabrication technique because air bubbles will be trapped in the mixture. Therefore, all ultrahigh frequency transducers currently used or under development are not properly matched because the lacking of desired matching layer materials. This problem hinders the development of finer resolution ultrahigh frequency ultrasonic imaging. There are some progress made in the past 3 years and there are sol-gel SiO2/polymer nano-composites being developed that can have acoustic impedance up to 5.7 MRays. In this thesis work, TiO2 nano-structured material has been developed. The material has porous nano-structure with the volume fraction of voids being controlled by the amount of bonding amorphous phase in the material and its acoustic impedance can be further tuned by heat treatment at slightly elevated temperatures. Using the quarter wavelength thickness characterization method, the acoustic properties of this nanostructured material were accurately characterized. It was found that the acoustic impedance can reach as high as 7.19 MRayls, which is a concrete improvement compared to that of the best nano-composites available. Because of recent rapid development of the single crystal PMN-PT and PZT-PT materials for medical ultrasonic transducer applications, there is a new excitement to develop transducers with very broad bandwidth because the electromechanical coupling coefficient of these single crystals are better than 90%. For such very broad bandwidth transducers, the front matching layer will be the limiting factor because the quarter wavelength matching layer acts like a filter whose bandwidth is generally less than 100%. One of the main tasks of this thesis is to investigate matching layer design with gradient acoustic impedance to achieve much broader bandwidth (>100%). Wave propagation within an

  13. Flexural Fillet Geometry Optimization for Design of Force Transducers Used in Aeronautics Testing

    Science.gov (United States)

    Lynn, Keith C.; Dixon, Genevieve

    2015-01-01

    Force transducer designs used in the ground testing aeronautics community have seen minimal change over the last few decades. With increased focus on data quality and long-term performance capabilities over the life of these instruments, it is critical to investigate new methods that improve these designs. One area of focus in the past few years at NASA has been on the design of the flexural elements of traditional force balance transducers. Many of the heritage balances that have been heavily used over the last few decades have started to develop fatigue cracks. The recent focus on the flexural design of traditional single-piece force balances revolves around the design of these elements such that stress concentrations are minimized, with the overall goal of increasing the fatigue life of the balance. Recent research in the area of using conic shaped fillets in the highly stressed regions of traditional force balances will be discussed, with preliminary numerical and experimental data results. A case study will be presented which discusses integration of this knowledge into a new high-capacity semi-span force balance.

  14. Design and analysis of fractional order seismic transducer for displacement and acceleration measurements

    Science.gov (United States)

    Veeraian, Parthasarathi; Gandhi, Uma; Mangalanathan, Umapathy

    2018-04-01

    Seismic transducers are widely used for measurement of displacement, velocity, and acceleration. This paper presents the design of seismic transducer in the fractional domain for the measurement of displacement and acceleration. The fractional order transfer function for seismic displacement and acceleration transducer are derived using Grünwald-Letnikov derivative. Frequency response analysis of fractional order seismic displacement transducer (FOSDT) and fractional order seismic acceleration transducer (FOSAT) are carried out for different damping ratio with the different fractional order, and the maximum dynamic measurement range is identified. The results demonstrate that fractional order seismic transducer has increased dynamic measurement range and less phase distortion as compared to the conventional seismic transducer even with a lower damping ratio. Time response of FOSDT and FOSAT are derived analytically in terms of Mittag-Leffler function, the effect of fractional behavior in the time domain is evaluated from the impulse and step response. The fractional order system is found to have significantly reduced overshoot as compared to the conventional transducer. The fractional order seismic transducer design proposed in this paper is illustrated with a design example for FOSDT and FOSAT. Finally, an electrical equivalent of FOSDT and FOSAT is considered, and its frequency response is found to be in close agreement with the proposed fractional order seismic transducer.

  15. Thermal stress in flexible interdigital transducers with anisotropic electroactive cellulose substrates

    Science.gov (United States)

    Yoon, Sean J.; Kim, Jung Woong; Kim, Hyun Chan; Kang, Jinmo; Kim, Jaehwan

    2017-12-01

    Thermal stress in flexible interdigital transducers a reliability concern in the development of flexible devices, which may lead to interface delamination, stress voiding and plastic deformation. In this paper, a mathematical model is presented to investigate the effect of material selections on the thermal stress in interdigital transducers. We modified the linear relationships in the composite materials theory with the effect of high curvature, anisotropic substrate and small substrate thickness. We evaluated the thermal stresses of interdigital transducers, fabricated with various electrodes, insulators and substrate materials for the comparison. The results show that, among various insulators, organic polymer developed the highest stress level while oxide showed the lowest stress level. Aluminium shows a higher stress level and curvature as an electrode than gold. As substrate materials, polyimide and electroactive cellulose show similar stress levels except the opposite sign convention to each other. Polyimide shows positive curvatures while electroactive cellulose shows negative curvatures, which is attributed to the stress and thermal expansion state of the metal/insulator composite. The results show that the insulator is found to be responsible for the confinement across the metal lines while the substrate is responsible for the confinement along the metal lines.

  16. The antenna-transducer mechanical coupling design for the Schenberg detector

    International Nuclear Information System (INIS)

    Melo, J L; Aguiar, O D; Jr, W F Velloso; Lucena, A U de

    2004-01-01

    We are designing microwave parametric transducers to be used in the Brazilian gravitational wave detector. In this paper, we explain the technical constraints used to design the mechanical parts of these transducers. The transducer and the antenna have been modelled by a finite element model (FEM) and the corresponding dynamical equations have been solved using the Msc/Nastran software. We have used the FEM analysis results in an iterative way, adjusting the geometric parameters in each step. Using this procedure we were able to calculate the transducer mechanical structure by positioning its main resonance frequency to the value of the sphere's quadrupolar mode frequency in order to design the best possible mechanical coupling and increasing transducer efficiency

  17. Characterization of HIFU transducers designed for sonochemistry application: Acoustic streaming.

    Science.gov (United States)

    Hallez, L; Touyeras, F; Hihn, J-Y; Bailly, Y

    2016-03-01

    Cavitation distribution in a High Intensity Focused Ultrasound sonoreactors (HIFU) has been extensively described in the recent literature, including quantification by an optical method (Sonochemiluminescence SCL). The present paper provides complementary measurements through the study of acoustic streaming generated by the same kind of HIFU transducers. To this end, results of mass transfer measurements (electrodiffusional method) were compared to optical method ones (Particle Image Velocimetry). This last one was used in various configurations: with or without an electrode in the acoustic field in order to have the same perturbation of the wave propagation. Results show that the maximum velocity is not located at the focal but shifted near the transducer, and that this shift is greater for high powers. The two cavitation modes (stationary and moving bubbles) are greatly affect the hydrodynamic behavior of our sonoreactors: acoustic streaming and the fluid generated by bubble motion. The results obtained by electrochemical measurements show the same low hydrodynamic activity in the transducer vicinity, the same shift of the active focal toward the transducer, and the same absence of activity in the post-focal axial zone. The comparison with theoretical Eckart's velocities (acoustic streaming in non-cavitating media) confirms a very high activity at the "sonochemical focal", accounted for by wave distortion, which induced greater absorption coefficients. Moreover, the equivalent liquid velocities are one order of magnitude larger than the ones measured by PIV, confirming the enhancement of mass transfer by bubbles oscillation and collapse close to the surface, rather than from a pure streaming effect. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Note: Decoupling design for high frequency piezoelectric ultrasonic transducers with their clamping connections

    Energy Technology Data Exchange (ETDEWEB)

    Wang, F. J., E-mail: wangfujun@tju.edu.cn; Liang, C. M.; Tian, Y. L.; Zhao, X. Y.; Zhang, D. W. [Tianjin Key Laboratory of Equipment Design and Manufacturing Technology, School of Mechanical Engineering, Tianjin University, Tianjin 300072 (China); Zhang, H. J. [Tianjin Key Laboratory of Modern Mechatronics Equipment Technology, School of Mechanical Engineering, Tianjin Polytechnic University, Tianjin 300387 (China)

    2015-12-15

    This work presents the flexure-mechanism based decoupling design between high frequency piezoelectric ultrasonic transducers and their clamping connections to improve ultrasonic energy transmission efficiency. The ring, prismatic beam, and circular notched hinge based flanges were presented, and the crucial geometric dimensions of the transducers with the flexure decoupling flanges were determined. Finite element analysis (FEA) was carried out to investigate the dynamic characteristics of the transducers. Finally, experiments were conducted to examine and verify the effects of the proposed decoupling flanges. FEA and experimental results show that smaller frequency deviations and larger tip displacement amplitudes have been achieved by using the transducers with the flexure flanges compared with the transducer with a rigid ring-type flange, and thus the ultrasonic transmission efficiency can be improved through the flexure flanges.

  19. Optimal Design of Electromagnetic Acoustic Transducer Used to Generate Lamb Wave

    Directory of Open Access Journals (Sweden)

    Yan LIU

    2014-01-01

    Full Text Available Electromagnetic ultrasonic transducer is the core component of the electromagnetic ultrasonic testing equipment. This paper establishes a three-dimensional model of the electromagnetic ultrasonic transducer used to generate Lamb wave, then by uniform design experiment and finite element analysis, the paper obtains the law between the eddy current density, the conductor width, length of the coil, the lift off distance, and the permanent magnets thickness. The law is verified by the experiment. It provides an overall principle for the optimal design of electromagnetic ultrasonic transducer.

  20. Design, development and metrological characterization of a low capacity precision industrial force transducer.

    Science.gov (United States)

    Kumar, Harish; Sharma, Chitra; Kumar, Anil; Arora, P K; Kumar, S

    2015-09-01

    The paper discusses the development of the ring shaped force transducers for measurement of force in lower capacity to meet the industrial requirements with the increasing technological developments. A 50 N ring shaped force transducer for tension mode has been developed by studying the analytical and computational methods. The force transducer developed has been metrologically studied according to the calibration procedure based on the standard ISO 376 and uncertainty of measurement of the force transducer is found to be±0.10% (k=2), while taking into account the relative uncertainty contribution due to necessary factors like repeatability, reproducibility, zero offset, interpolation, resolution and reversibility. The force transducer developed may further be studied for improvement of metrological performance and may suitably be developed for other lower capacities like 10 N, 20 N etc. The force transducer developed offers very economical alternative of complex shaped force transducers with simple design and manufacturing features. The force transducer developed may be proved very helpful in providing traceability to the user industries and calibration laboratories in the lower range of force measurement and serve as force transfer standard. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  1. Improving the Design of Capacitive Micromachined Ultrasonic Transducers Aided with Sensitivity Analysis

    Directory of Open Access Journals (Sweden)

    A Martowicz

    2016-09-01

    Full Text Available The paper presents the results of analysis performed to search for feasible design improvements for capacitive micromachined ultrasonic transducer. Carried out search has been aided with the sensitivity analysis and the application of Response Surface Method. The multiphysics approach has been taken into account in elaborated finite element model of one cell of described transducer in order to include significant physical phenomena present in modelled microdevice. The set of twelve input uncertain and design parameters consists of geometric, material and control properties. The amplitude of dynamic membrane deformation of the transducer has been chosen as studied parameter. The objective of performed study has been defined as the task of finding robust design configurations of the transducer, i.e. characterizing maximal value of deformation amplitude with its minimal variation.

  2. Design and Functional Validation of a Complex Impedance Measurement Device for Characterization of Ultrasonic Transducers

    International Nuclear Information System (INIS)

    De-Cock, Wouter; Cools, Jan; Leroux, Paul

    2013-06-01

    This paper presents the design and practical implementation of a complex impedance measurement device capable of characterization of ultrasonic transducers. The device works in the frequency range used by industrial ultrasonic transducers which is below the measurement range of modern high end network analyzers. The device uses the Goertzel algorithm instead of the more common FFT algorithm to calculate the magnitude and phase component of the impedance under test. A theoretical overview is given followed by a practical approach and measurement results. (authors)

  3. Capacitive micromachined ultrasound transducer (cMUT) for immunosensor design.

    Science.gov (United States)

    Ramanaviciene, Almira; Virzonis, Darius; Vanagas, Gailius; Ramanavicius, Arūnas

    2010-07-01

    An affinity sensor based on a capacitive micromachined ultrasound transducer (cMUT) is reported by this Communication. The cMUT micromembrane arrays modified with adsorbed bovine leukemia virus protein gp51 were applied as a biological recognition part. The cMUT-based sensor is shown to be sensitive to the antibodies against bovine leukemia virus protein gp51 (anti-gp51). Two different concentrations of anti-gp51-containing samples and one blank sample without anti-gp51 were tested. The sensitivity of cMUT-based immunosensor is comparable with the sensitivity of a quartz microbalance-based immunosensor. The cMUT array provides a multi-channel system for the measurement of analytical signal. Moreover, two different characteristics--the resonance frequency shift (Deltaf) and the shift of the real part of the electromechanical impedance (DeltaRe)--could have been evaluated simultaneously. Both analytical signals are informative and can be applied for the estimation of immune complex formation. We found the performance of such a system being potentially superior over some other immunosensing techniques. It is more rapid than electrochemical techniques and provides two different informative parameters.

  4. Design and fabrication of a double-sided piezoelectric transducer for harvesting vibration power

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Wei-Tsai; Chen, Ying-Chung [Department of Electrical Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan, ROC (China); Kao, Kuo-Sheng [Department of Computer and Communication, Shu-Te University, Kaohsiung, Taiwan, ROC (China); Chu, Yu-Hsien [Department of Electrical Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan, ROC (China); Cheng, Chien-Chuan, E-mail: chengccc@dlit.edu.tw [Department of Electronic Engineering, De Lin Institute of Technology, Taipei, Taiwan, ROC (China)

    2013-02-01

    This investigation examines a means of integrating high-performance ZnO piezoelectric thin films with a flexible stainless steel substrate (SUS304) to fabricate a double-sided piezoelectric transducer for vibration-energy harvesting applications. The double-sided piezoelectric transducer is constructed by depositing ZnO piezoelectric thin films on both the front and the back sides of the SUS304 substrate. The titanium and platinum layers were deposited using a dual-gun DC sputtering system between the ZnO piezoelectric thin film and the back side of the SUS304 substrate. The scanning electron microscopy and X-ray diffraction of ZnO piezoelectric films reveal a rigid surface structure and a highly c-axis-preferring orientation. To fabricate a transducer with a low resonant frequency, a tip-mass of 0.5 g and a vibration-area of 1 cm{sup 2} are designed, based on the cantilever vibration theory. The maximum open circuit voltage of the power transducer is approximately 18 V. After rectification and filtering through a 33 nF capacitor, a specific power output of 1.31 μW/cm{sup 2} is obtained from the transducers with a load resistance of 6 MΩ. The variation of the power output of ± 0.001% is obtained after 24-hour continuous test. - Highlights: ► A double-sided piezoelectric transducer is fabricated with the ZnO thin films. ► Vibrated frequency of a double-sided transducer is designed and presented. ► A maximum output power of 3.23 μW/cm{sup 2} is obtained under turbulent vibration.

  5. Fine-Tuning ER Stress Signal Transducers to Treat Amyotrophic Lateral Sclerosis

    Directory of Open Access Journals (Sweden)

    Danilo B. Medinas

    2017-07-01

    Full Text Available Amyotrophic lateral sclerosis (ALS is a fatal neurodegenerative disease characterized by the progressive loss of motoneurons and paralysis. The mechanisms underlying neuronal degeneration in ALS are starting to be elucidated, highlighting disturbances in motoneuron proteostasis. Endoplasmic reticulum (ER stress has emerged as an early pathogenic event underlying motoneuron vulnerability and denervation in ALS. Maintenance of ER proteostasis is controlled by a dynamic signaling network known as the unfolded protein response (UPR. Inositol-requiring enzyme 1 (IRE1 is an ER-located kinase and endoribonuclease that operates as a major ER stress transducer, mediating the establishment of adaptive and pro-apoptotic programs. Here we discuss current evidence supporting the role of ER stress in motoneuron demise in ALS and build the rational to target IRE1 to ameliorate neurodegeneration.

  6. Initial Design and Quick Analysis of SAW Ultra–Wideband HFM Transducers

    Directory of Open Access Journals (Sweden)

    A. Janeliauskas

    2017-09-01

    Full Text Available This paper presents techniques for initial design and quick fundamental and harmonic operation analysis of surface acoustic waves ultra–wideband hyperbolically frequency modulated (HFM interdigital transducer (IDT. The primary analysis is based on the quasi–static method. Quasi–electrostatic charge's density distribution was approximated by Chebyshev polynomials and the method of Green’s function. It assesses the non uniform charge distribution of electrodes, electric field interaction and the end effects of a whole transducer. It was found that numerical integration (e.g. Romberg, Gauss–Chebyshev requires a lot of machine time for calculation of the Chebyshev polynomial and the Green’s function convolution when integration includes coordinates of a large number of neighboring electrodes. In order to accelerate the charge density calculation, the analytic expressions are derived. Evaluation of HFM transducer fundamental and harmonics' operation amplitude response with simulation single–dispersive interdigital chirp filter structure is presented. Elapsed time of HFM IDT with 589 electrodes simulations and 2000 frequency response point is only 54 seconds (0.027 s/point on PC with CPU Intel Core I7–4770S. Amplitude response is compared with linear frequency modulated (LFM IDT response. It was determined that the HFM transducer characteristic is less distorted in comparison with LFM transducer.

  7. Platform based design of EAP transducers in Danfoss PolyPower A/S

    DEFF Research Database (Denmark)

    Sarban, Rahimullah; Guðlaugsson, Tómas Vignir

    2013-01-01

    organizations. The aim of the project is to develop platform based designs and product family for the EAP components to be used in variety of applications. This paper presents the structure of the platform project as a whole and specifically the platform based designs of EAP transducers. The underlying...... for a new area of research namely product development emerges. Product development can be based on an isolated design and production for a single product or platform design where a product family is developed. In platform design the families of products exploits commonality of platform modules while...... technologies, essential for EAP transducers, are also presented. Conceptual design and solution for the concepts are presented as well. © 2013 SPIE....

  8. Design and fabrication of liner-arroy ultrasonic transducer using KLM and FEM simulation for non-destructive testing

    International Nuclear Information System (INIS)

    Park, Chan Yuk; Sung, Jin Ho; Jeong, Jong Seob

    2015-01-01

    In this paper, a linear-array transducer capable of overcoming the faults of a single element and phased array transducers with convex shape for non-destructive ultrasonic testing was designed and fabricated. A 5.5 MHz linear-array transducer was designed using the PiezoCAD program based on the KLM analysis and the PZFlex program based on the FEM analysis. A 2-2 composite structure was employed to achieve broad-band characteristics. A 128 element linear-array transducer was fabricated and its performance was compared with the simulation results. The center frequency of the fabricated transducer was 5.5 Mhzand the -6 dB frequency bandwidth was 70 %. Thus, we expect that the designed transducer can provide an effective inner image of the test material during non-destructive ultrasonic testing.

  9. Design rules for superconducting analog-digital transducers

    International Nuclear Information System (INIS)

    Haddad, Taghrid

    2015-01-01

    This Thesis is a contribution for dimensioning aspects of circuits designs in superconductor electronics. Mainly superconductor comparators inclusive Josephson comparators as well as QOJS-Comparators are investigated. Both types were investigated in terms of speed and sensitivity. The influence of the thermal noise on the decision process of the comparators represent in so called gray zone, which is analysed in this thesis. Thereby, different relations between design parameters were derived. A circuit model of the Josephson comparator was verified by experiments. Concepts of superconductor analog-to-digital converters, which are based on above called comparators, were investigated in detail. From the comparator design rules, new rules for AD-converters were derived. Because of the reduced switching energy, the signal to noise ratio (SNR) of the circuits is affected and therefore the reliability of the decision-process is affected. For special applications with very demanding requirements in terms of the speed and accuracy superconductor analog-to-digital converters offer an excellent performance. This thesis provides relations between different design paramenters and shows resulting trade-offs, This method is transparent and easy to transfer to other circuit topologies. As a main result, a highly predictive tool for dimensioning of superconducting ADC's is proved.

  10. Interdigital Piezopolymer Transducers for Time of Flight Measurements with Ultrasonic Lamb Waves on Carbon-Epoxy Composites under Pure Bending Stress

    Directory of Open Access Journals (Sweden)

    Andrea Bulletti

    2015-01-01

    Full Text Available Interdigital transducers fabricated with piezopolymer film have been realized to excite ultrasonic Lamb waves in a composite laminate subjected to pure bending stresses. Lamb waves were generated and detected in a cross-ply [0°/90°] 4 mm thick carbon-fiber composite, by using two interdigital transducers in pitch-catch configuration. We demonstrate that the choice of the piezopolymer transducer technology is suitable for this type of investigation and the advantages of the proposed transducer assembly and bonding are described. A full set-up is described to determine the relationship between the time of flight of the recorded signals and the applied bending moment. Interdigital transducers were designed according to simulations of the dispersion curves, in order to operate at a central frequency of 450 kHz. This frequency corresponds to a central wavelength of 16 mm and to a group velocity of about 6000 m/s for the first symmetric guided wave mode. The variations in the time of flight of ultrasonic recorded signals were measured as a function of the variations in the bending moment. The static and dynamic load tests were in good agreement with strain gage measurements performed in the micro deformation range (0–1400 µm/m.

  11. Optimization Design Method for the CMOS-type Capacitive Micro-Machined Ultrasonic Transducer

    Directory of Open Access Journals (Sweden)

    D. Y. Chiou

    2011-12-01

    Full Text Available In this study, an integrated modeling technique for characterization and optimization design of the complementary metal-oxide-semiconductor (CMOS capacitive micro-arrayed ultrasonic transducer (pCMOS-CMUT is presented. Electromechanical finite element simulations are performed to investigate its operational characteristics, such as the collapse voltage and the resonant frequency. Both the numerical and experimental results are in good agreement. In order to simultaneously customize the resonant frequency and minimize the collapse voltage, the genetic algorithm (GA is applied to optimize dimensional parameters of the transducer. From the present results, it is concluded that the FE/GA coupling approach provides another efficient numerical tool for multi-objective design of the pCMOS-CMUT.

  12. Actuating mechanism and design of a cylindrical traveling wave ultrasonic motor using cantilever type composite transducer.

    Directory of Open Access Journals (Sweden)

    Yingxiang Liu

    Full Text Available BACKGROUND: Ultrasonic motors (USM are based on the concept of driving the rotor by a mechanical vibration excited on the stator via piezoelectric effect. USM exhibit merits such as simple structure, quick response, quiet operation, self-locking when power off, nonelectromagnetic radiation and higher position accuracy. PRINCIPAL FINDINGS: A cylindrical type traveling wave ultrasonic motor using cantilever type composite transducer was proposed in this paper. There are two cantilevers on the outside surface of cylinder, four longitudinal PZT ceramics are set between the cantilevers, and four bending PZT ceramics are set on each outside surface of cantilevers. Two degenerate flexural vibration modes spatially and temporally orthogonal to each other in the cylinder are excited by the composite transducer. In this new design, a single transducer can excite a flexural traveling wave in the cylinder. Thus, elliptical motions are achieved on the teeth. The actuating mechanism of proposed motor was analyzed. The stator was designed with FEM. The two vibration modes of stator were degenerated. Transient analysis was developed to gain the vibration characteristic of stator, and results indicate the motion trajectories of nodes on the teeth are nearly ellipses. CONCLUSIONS: The study results verify the feasibility of the proposed design. The wave excited in the cylinder isn't an ideal traveling wave, and the vibration amplitudes are inconsistent. The distortion of traveling wave is generated by the deformation of bending vibration mode of cylinder, which is caused by the coupling effect between the cylinder and transducer. Analysis results also prove that the objective motions of nodes on the teeth are three-dimensional vibrations. But, the vibration in axial direction is minute compared with the vibrations in circumferential and radial direction. The results of this paper can guide the development of this new type of motor.

  13. Platform based design of EAP transducers in Danfoss PolyPower A/S

    Science.gov (United States)

    Sarban, Rahimullah; Gudlaugsson, Tómas V.

    2013-04-01

    Electroactive Polymer (EAP) has gained increasing focus, in research communities, in last two decades. Research within the field of EAP has, so far, been mainly focused on material improvements, characterization, modeling and developing demonstrators. As the EAP technology matures, the need for a new area of research namely product development emerges. Product development can be based on an isolated design and production for a single product or platform design where a product family is developed. In platform design the families of products exploits commonality of platform modules while satisfying a variety of different market segments. Platform based approach has the primary benefit of being cost efficient and short lead time to market when new products emerges. Products development based on EAP technology is challenging both technologically as well as from production and processing point of view. Both the technological and processing challenges need to be addressed before a successful implementation of EAP technology into products. Based on this need Danfoss PolyPower A/S has, in 2011, launched a EAP platform project in collaboration with three Danish universities and three commercial organizations. The aim of the project is to develop platform based designs and product family for the EAP components to be used in variety of applications. This paper presents the structure of the platform project as a whole and specifically the platform based designs of EAP transducers. The underlying technologies, essential for EAP transducers, are also presented. Conceptual design and solution for the concepts are presented as well.

  14. Stress sensing in plants by the ER stress sensor/transducer, bZIP28

    Directory of Open Access Journals (Sweden)

    Renu eSrivastava

    2014-02-01

    Full Text Available Two classes of ER stress sensors are known in plants, membrane associated bZIP transcription factors and RNA splicing factors. ER stress occurs under adverse environmental conditions and results from the accumulation of misfolded or unfolded proteins in the ER lumen. One of the membrane-associated transcription factors activated by heat and ER stress agents is bZIP28. In its inactive form, bZIP28 is a type II protein with a single pass transmembrane domain, residing in the ER. bZIP28’s N-terminus, containing a transcriptional activation domain, is oriented towards the cytoplasm and its C-terminal tail is inserted into the ER lumen. In response to stress, bZIP28 exits the ER and moves to the Golgi where it is proteolytically processed, liberating its cytosolic component which relocates to the nucleus to upregulate stress-response genes. bZIP28 is thought to sense stress through its interaction with the major ER chaperone, BIP. BiP binds to bZIP28’s lumenal domain under unstressed conditions and retains it in the ER. BIP binds to the intrinsically disordered regions on bZIP28’s lumen-facing tail. A truncated form of bZIP28, without its C-terminal tail is not retained in the ER but migrates constitutively to the nucleus. Upon stress, BiP releases bZIP28 allowing it to exit the ER. One model to account for the release of bZIP28 by BiP is that BiP is competed away from bZIP28 by the accumulation of misfolded proteins in the ER. However, other forces such as changes in energy charge levels, redox conditions or interaction with DNAJ proteins may also promote release of bZIP28 from BiP. Movement of bZIP28 from the ER to the Golgi is assisted by the interaction of elements of the COPII machinery with the cytoplasmic domain of bZIP28. Thus, the mobilization of bZIP28 in response to stress involves the dissociation of factors that retain it in the ER and the association of factors that mediate its further organelle-to-organelle movement.

  15. A study on the performance of piezoelectric composite materials for designing embedded transducers for concrete assessment

    Science.gov (United States)

    Dumoulin, Cédric; Deraemaeker, Arnaud

    2018-03-01

    radial mode of the latter is responsible for an acoustic response of the same order of magnitude as those for the piezo-composites. This result confirms that the design of efficient low-cost embedded ultrasonic transducers can be done with such piezoceramic disks.

  16. Design and Modeling of High Power Density Acoustic Transducer Materials for Autonomous Undersea Vehicles

    Science.gov (United States)

    Heitmann, Adam Arthur

    Advances in piezocrystal transducer materials technology has opened new avenues to impact the size, weight, and power consumption of sonar systems for deployment in autonomous undersea vehicles (AUVs). Although piezocrystals exhibit exceptional electromechanical properties, they have low ferroelectric Curie temperatures, small electrical coercivities, and exhibit temperature, electrical field, and/or stress induced phase transitions between ferroelectric phases with differing electromechanical properties. New piezocrystal materials are required that can provide the compositional tailoring capability needed to increase the Curie temperature and coercive field, ameliorate the deleterious effects of ferroelectric-ferroelectric phase transitions, and enable property optimization for specific transducer applications. Currently, new piezocrystal systems and compositions are selected almost exclusively by empirical 'make and measure' approaches guided by past experiences. These empirical processes can be time and labor intensive and as a result there exists only limited predictive capability for finding new piezocrystal compositions even in known piezocrystal systems. In this study we seek to develop a comprehensive phenomenological theory and a unified parameterization scheme applicable to binary and ternary ferroelectric solid solution systems in order to enable the accelerated development and characterization of new piezocrystal systems for optimized transducer performance. A modified form of the classical Ginzburg-Landau-Devonshire theory of weak first-order transitions is applied to perovskite-structured ferroelectric systems based on the ternary oxide compounds, barium titanate and lead titanate, which places special emphasis on the role played by the crystallographic anisotropy of polarization. It is shown that the theory produces excellent qualitative agreement with the experimentally measured phase diagram topologies, crystal lattice parameters, and

  17. Modeling and Design of Capacitive Micromachined Ultrasonic Transducers Based-on Database Optimization

    International Nuclear Information System (INIS)

    Chang, M W; Gwo, T J; Deng, T M; Chang, H C

    2006-01-01

    A Capacitive Micromachined Ultrasonic Transducers simulation database, based on electromechanical coupling theory, has been fully developed for versatile capacitive microtransducer design and analysis. Both arithmetic and graphic configurations are used to find optimal parameters based on serial coupling simulations. The key modeling parameters identified can improve microtransducer's character and reliability effectively. This method could be used to reduce design time and fabrication cost, eliminating trial-and-error procedures. Various microtransducers, with optimized characteristics, can be developed economically using the developed database. A simulation to design an ultrasonic microtransducer is completed as an executed example. The dependent relationship between membrane geometry, vibration displacement and output response is demonstrated. The electromechanical coupling effects, mechanical impedance and frequency response are also taken into consideration for optimal microstructures. The microdevice parameters with the best output signal response are predicted, and microfabrication processing constraints and realities are also taken into consideration

  18. Characterization and Optimization Design of the Polymer-based Capacitive Micro-arrayed Ultrasonic Transducer

    Directory of Open Access Journals (Sweden)

    De-Yi CHIOU

    2007-10-01

    Full Text Available The polymer-based capacitive micro-arrayed ultrasonic transducers have been investigated using the finite element analysis. The ANSYS Multiphysics solver with sequential approach and the physics environment files are applied for the solution of the electrostatic-structural coupled-field problem. A 2-D electromechanical model is established to characterize the collapse voltage and the resonant frequency of the P-CMUT. Both the numerical and experimental results were in good agreement. An integrated multi-objective design method involving electrical and mechanical characterization was developed to optimize the geometric parameters of the P-CMUT. The optimization search routine conducted using the genetic algorithm (GA is connected with the ANSYS model to obtain the best design variable. The optimal results show that the proposed approach provides another efficient and versatile numerical tool for multi-objective design and optimization of the P-CMUT.

  19. Design and Use of Capacitive Force Transducers for Superconducting Magnet Models for the LHC

    CERN Document Server

    Siegel, N; Vanenkov, I

    1998-01-01

    Capacitive force transducers have been developed and used for monitoring the coil pre-stress during assembly and excitation of several dipole models for LHC. Typically these gauges are strips several tenths of millimeter thick that can be made according to a large variety of geometries. Inserted between two surfaces, they allow to measure the distribution of contact pressures up to 200 MPa from am bient temperature to superfluid helium also in presence of a static magnetic field. The sequence and quality of the manufacturing steps are determining factors in the performance of this kind of gauge s. The paper describes the basic principles, possible configuration geometries, fabrication and calibration procedures of these gauges. Finally the applications of capacitive gauges in the framework o f the R&D programme of superconducting short dipole models for LHC are reviewed and discussed.

  20. Simulation-based optimization of the design and settings of ultrasonic phased-array transducers with an evolutionary algorithm

    International Nuclear Information System (INIS)

    Puel, B.; Chatillon, S.; Calmon, P.; Lesselier, D.

    2011-01-01

    The design of an ultrasonic array and its settings for a specific inspection involves multiple parameters and is the result of a compromise between different requirements and limitations. Parametric studies based on simulation tools are often performed to ensure that the transducer has suitable performances in terms of detection of the defects sought. An automatic optimization tool, based on an evolutionary algorithm driving CIVA's simulation data, is proposed and tested in realistic applications to design inspection parameters (designing, positioning and/or setting the transducer). (authors)

  1. Numerical design and analysis of a compact TE10 to TE01 mode transducer

    International Nuclear Information System (INIS)

    Tantawi, S.; Ko, K.; Kroll, N.

    1993-04-01

    A high-power low-loss mode transducer design has been proposed to adapt the output of the X-Band klystron, WR90 rectangular waveguide, to the input of the pulse compression system, SLED II, which utilizes overmoded circular waveguides operating in the low-loss TE 01 mode. This device is much more compact than the conventional Marie type mode converters. The device splits the incoming klystron output into two separate rectangular guides that are then fed into a circular guide through a four-slot arrangement. We will use both MAFIA and HFSS to calculate the transmission properties of the three-dimensional structure. We will also determine the extent of mode contamination and compare the numerical results with experiments

  2. The design and calibration of particular geometry piezoelectric acoustic emission transducer for leak detection and localization

    Science.gov (United States)

    Yalcinkaya, Hazim; Ozevin, Didem

    2013-09-01

    Pipeline leak detection using an acoustic emission (AE) method requires highly sensitive transducers responding to less attenuative and dispersive wave motion in order to place the discrete transducer spacing in an acceptable approach. In this paper, a new piezoelectric transducer geometry made of PZT-5A is introduced to increase the transducer sensitivity to the tangential direction. The finite element analysis of the transducer geometry is modeled in the frequency domain to identify the resonant frequency, targeting 60 kHz, and the loss factor. The numerical results are compared with the electromechanical characterization tests. The transducer response to wave motion generated in different directions is studied using a multiphysics model that couples mechanical and electrical responses of structural and piezoelectric properties. The directional dependence and the sensitivity of the transducer response are identified using the laser-induced load function. The transducer response is compared with a conventional thickness mode AE transducer under simulations and leak localization in a laboratory scale steel pipe.

  3. A Newly Designed Fiber-Optic Based Earth Pressure Transducer with Adjustable Measurement Range

    Directory of Open Access Journals (Sweden)

    Hou-Zhen Wei

    2018-03-01

    Full Text Available A novel fiber-optic based earth pressure sensor (FPS with an adjustable measurement range and high sensitivity is developed to measure earth pressures for civil infrastructures. The new FPS combines a cantilever beam with fiber Bragg grating (FBG sensors and a flexible membrane. Compared with a traditional pressure transducer with a dual diaphragm design, the proposed FPS has a larger measurement range and shows high accuracy. The working principles, parameter design, fabrication methods, and laboratory calibration tests are explained in this paper. A theoretical solution is derived to obtain the relationship between the applied pressure and strain of the FBG sensors. In addition, a finite element model is established to analyze the mechanical behavior of the membrane and the cantilever beam and thereby obtain optimal parameters. The cantilever beam is 40 mm long, 15 mm wide, and 1 mm thick. The whole FPS has a diameter of 100 mm and a thickness of 30 mm. The sensitivity of the FPS is 0.104 kPa/με. In addition, automatic temperature compensation can be achieved. The FPS’s sensitivity, physical properties, and response to applied pressure are extensively examined through modeling and experiments. The results show that the proposed FPS has numerous potential applications in soil pressure measurement.

  4. Design and fabrication of conductive polyaniline transducers via computer controlled direct ink writing

    Science.gov (United States)

    Holness, F. Benjamin; Price, Aaron D.

    2017-04-01

    The intractable nature of the conjugated polymer (CP) polyaniline (PANI) has largely limited PANI-based transducers to monolithic geometries derived from thin-film deposition techniques. To address this limitation, we have previously reported additive manufacturing processes for the direct ink writing of three-dimensional electroactive PANI structures. This technology incorporates a modified delta robot having an integrated polymer paste extrusion system in conjunction with a counter-ion induced thermal doping process to achieve these 3D structures. In this study, we employ an improved embodiment of this methodology for the fabrication of functional PANI devices with increasingly complex geometries and enhanced electroactive functionality. Advances in manufacturing capabilities achieved through the integration of a precision pneumatic fluid dispenser and redesigned high-pressure end-effector enable extrusion of viscous polymer formulations, improving the realizable resolutions of features and deposition layers. The integration of a multi-material dual-extrusion end-effector has further aided the fabrication of these devices, enabling the concurrent assembly of passive and active structures, which reduces the limitations on device geometry. Subsequent characterization of these devices elucidates the relationships between polymer formulation, process parameters, and device design such that electromechanical properties can be tuned according to application requirements. This methodology ultimately leads to the improved manufacturing of electroactive polymer-enabled devices with high-resolution 3D features and enhanced electroactive performance.

  5. Kallikrein transduced mesenchymal stem cells protect against anti-GBM disease and lupus nephritis by ameliorating inflammation and oxidative stress.

    Directory of Open Access Journals (Sweden)

    Yajuan Li

    Full Text Available Previously we have shown that kallikreins (klks play a renoprotective role in nephrotoxic serum induced nephritis. In this study, we have used mesenchymal stem cells (MSCs as vehicles to deliver klks into the injured kidneys and have measured their therapeutic effect on experimental antibody induced nephritis and lupus nephritis. Human KLK-1 (hKLK1 gene was transduced into murine MSCs using a retroviral vector to generate a stable cell line, hKLK1-MSC, expressing high levels of hKLK1. 129/svj mice subjected to anti-GBM induced nephritis were transplanted with 10(6 hKLK1-MSCs and hKLK1 expression was confirmed in the kidneys. Compared with vector-MSCs injected mice, the hKLK1-MSCs treated mice showed significantly reduced proteinuria, blood urea nitrogen (BUN and ameliorated renal pathology. Using the same strategy, we treated lupus-prone B6.Sle1.Sle3 bicongenic mice with hKLK1-MSCs and demonstrated that hKLK1-MSCs delivery also attenuated lupus nephritis. Mechanistically, hKLK1-MSCs reduced macrophage and T-lymphocyte infiltration into the kidney by suppressing the expression of inflammation cytokines. Moreover, hKLK1 transduced MSCs were more resistant to oxidative stress-induced apoptosis. These findings advance genetically modified MSCs as potential gene delivery tools for targeting therapeutic agents to the kidneys in order to modulate inflammation and oxidative stress in lupus nephritis.

  6. Reducing the Effect of Transducer Mount Induced Noise (XMIN) on Aeroacoustic Wind Tunnel Testing Data with a New Transducer Mount Design

    Science.gov (United States)

    Herron, Andrew J.; Reed, Darren K.; Nance, Donald K.

    2015-01-01

    Characterization of flight vehicle unsteady aerodynamics is often studied via large scale wind tunnel testing. Boundary layer noise is measured by miniature pressure transducers installed in a model. Noise levels (2-5 dB ref. 20 µPa) can be induced when transducer is mounted out of flush with model outer surface. This effect must be minimized to accurately determine aerodynamically induced acoustic environments.

  7. Design, simulation and testing of capacitive micromachined ultrasound transducer-based phospholipidic biosensor elements

    International Nuclear Information System (INIS)

    Sapeliauskas, E; Vanagas, G; Barauskas, D; Mikolajunas, M; Pakenas, E; Pelenis, D; Sergalis, G; Jukna, T; Virzonis, D

    2015-01-01

    In this study we present theoretical proof of the principle of using interdigital capacitive micromachined ultrasound transducers (CMUT IDTs) for the detection of phospholipid membrane elasticity. Proof of principle was needed to find out whether the new type of microelectromechanical sensors of the toxins incorporated with the lipid membranes was feasible. CMUT IDTs for 10 MHz operation in water, with 146 µm spaced double fingers were designed and fabricated using the surface micromachining technique. Fabricated CMUTs were tested for their resonance in air and for Scholte-type wave transmission in deionized water and isopropanol solutions containing 0%, 10% and 20% water. The amplitude and phase velocity of the excited and received Scholte waves were measured in a 200 µm height microchannel, capped with a thick layer of soft polymer, which suppressed the production of non-informative guided waves. It was determined that the average sensitivity of Scholte wave phase velocity within the given range of solution concentrations is 2.9 m s −1 per one percent. Experimental data were also used to verify the adequacy of the finite element model, which was found to be suitable for reliable prediction of the phospholipid membrane elasticity impact on the Scholte wave phase velocity or the resonance frequency in the present IDT structure. It was determined that for the analyzed conditions (the elasticity of simulated phospholipid membrane changed from 1 to 5 GPa) the sensitivity of the measurement channel is expected to be no worse than 2 kHz GPa −1 in terms of the Scholte wave and CMUT IDT resonance frequency. This leads to a positive conclusion on the feasibility of the new sensor type. (paper)

  8. Design, simulation and testing of capacitive micromachined ultrasound transducer-based phospholipidic biosensor elements

    Science.gov (United States)

    Sapeliauskas, E.; Vanagas, G.; Barauskas, D.; Mikolajunas, M.; Pakenas, E.; Pelenis, D.; Sergalis, G.; Jukna, T.; Virzonis, D.

    2015-07-01

    In this study we present theoretical proof of the principle of using interdigital capacitive micromachined ultrasound transducers (CMUT IDTs) for the detection of phospholipid membrane elasticity. Proof of principle was needed to find out whether the new type of microelectromechanical sensors of the toxins incorporated with the lipid membranes was feasible. CMUT IDTs for 10 MHz operation in water, with 146 µm spaced double fingers were designed and fabricated using the surface micromachining technique. Fabricated CMUTs were tested for their resonance in air and for Scholte-type wave transmission in deionized water and isopropanol solutions containing 0%, 10% and 20% water. The amplitude and phase velocity of the excited and received Scholte waves were measured in a 200 µm height microchannel, capped with a thick layer of soft polymer, which suppressed the production of non-informative guided waves. It was determined that the average sensitivity of Scholte wave phase velocity within the given range of solution concentrations is 2.9 m s-1 per one percent. Experimental data were also used to verify the adequacy of the finite element model, which was found to be suitable for reliable prediction of the phospholipid membrane elasticity impact on the Scholte wave phase velocity or the resonance frequency in the present IDT structure. It was determined that for the analyzed conditions (the elasticity of simulated phospholipid membrane changed from 1 to 5 GPa) the sensitivity of the measurement channel is expected to be no worse than 2 kHz GPa-1 in terms of the Scholte wave and CMUT IDT resonance frequency. This leads to a positive conclusion on the feasibility of the new sensor type.

  9. Subminiature eddy-current transducers designed to study welded joints of titanium alloys

    Science.gov (United States)

    Malikov, V. N.; Dmitriev, S. F.; Katasonov, A. O.; Sagalakov, A. M.; Ishkov, A. V.

    2017-12-01

    Eddy current transducers (ECT) are used to construct a sensor for investigating titanium sheets connected by a welded joint. The paper provides key technical information about the eddy current transducer used and describes the procedure of measurements that makes it possible to control defects in welded joints of titanium alloys. It is capable of automatically changing the filtering cutoff frequency and operating frequency of the device. Experiments were conducted on welded VT1-0 titanium plates. The paper contains the results of these measurements. The dependence data facilitates the assessment of the quality of the welded joints and helps make an educated conclusion about welding quality.

  10. Optical-Interferometry-Based CMOS-MEMS Sensor Transduced by Stress-Induced Nanomechanical Deflection

    Science.gov (United States)

    Maruyama, Satoshi; Hizawa, Takeshi; Takahashi, Kazuhiro; Sawada, Kazuaki

    2018-01-01

    We developed a Fabry–Perot interferometer sensor with a metal-oxide-semiconductor field-effect transistor (MOSFET) circuit for chemical sensing. The novel signal transducing technique was performed in three steps: mechanical deflection, transmittance change, and photocurrent change. A small readout photocurrent was processed by an integrated source follower circuit. The movable film of the sensor was a 350-nm-thick polychloro-para-xylylene membrane with a diameter of 100 µm and an air gap of 300 nm. The linearity of the integrated source follower circuit was obtained. We demonstrated a gas response using 80-ppm ethanol detected by small membrane deformation of 50 nm, which resulted in an output-voltage change with the proposed high-efficiency transduction. PMID:29304011

  11. Mechanical Pre-Stressing a Transducer through a Negative DC Biasing Field

    Science.gov (United States)

    2017-04-21

    ceramic drive element that is sandwiched between two masses, a tail mass, a radiating head mass, and a stress bolt. The stress bolt that passes ...drive element is typically composed of many piezoelectric ceramic rings that are epoxied mechanically in series and electrically connected in...of the head mass creates sound waves by compressing the water in front of the piston. A stress bolt or tie rod that passes through the ceramic

  12. Transducer for measuring normal and friction stress in contact zone during rolling

    DEFF Research Database (Denmark)

    Henningsen, Poul; Wanheim, Tarras; Arentoft, Mogens

    2004-01-01

    by the friction conditions. To achieve this important information, measurements of the normal pressure and friction stresses in the deformation zone are requested. The interface conditions are analyzed by several authors [1-8] The direction of the friction stress is changing during the rolling gap....... At the entrance of the deformation zone, the peripherical velocity of the roll is higher than for the incoming material, which causes frictional stresses at the material acting in the rolling direction. At the outlet of the rolling gap, the velocity of the deformed material exceeds the velocity of the roll......, generating frictional stresses contrary to the direction of rolling. In a narrow area in the deformation zone, the velocity of the deformed material is equal to the velocity of the rolls. This area or line is named “neutral line”[2]. The position of the neutral line depends on friction, reduction ratio...

  13. Metal rings and discs Matlab/Simulink 3D model for ultrasonic sandwich transducer design

    Directory of Open Access Journals (Sweden)

    Jovanović I.

    2012-01-01

    Full Text Available Metal-endings are integral part of different ultrasonic sandwich transducers. In this paper a new Matlab/Simulink 3D model of the finite metal rings and discs of various dimensions is realized. With this model, which describes both the thickness and the radial resonant modes, and the coupling between them, mechanical impedance of the sample can be easily computed. Resonance frequency-length curves for rings and disks with various materials and for different selected dimensions are given. Also, comparisons of the different approaches in determining of their resonant frequencies are shown. The proposed Matlab/Simulink model requires simpler implementation than other analytical models. That enabled modifying of 1D theory and simplified modelling and projecting of the ultrasonic sandwich transducers with short-endings. Finally, the computed and experimental results are compared. [Projekat Ministarstva nauke Republike Srbije, br. TR33035, br. III43014 i br. OI172057

  14. Design and analysis of an ultrasonic transducer micro-array for near-field imaging of age related macular degeneration

    Science.gov (United States)

    Clarke, Clyde C.

    Obtaining quantitative data about tissue has been a goal of ultrasonography since its inception, such data provides invaluable information for diagnosing disease. Traditional ultrasound imaging techniques (B-Mode, C-Mode and M-Mode) have been used to diagnose diseases from images of organs. However, images obtained via these techniques, in some cases, provide limited information about the pathology of the tissues being examined. This is because much of the information that is used for diagnosis depends upon qualitative cues emerging from the echoic profiles of bulk tissue properties. In order to obtain quantitative information about tissue properties, an understanding of the interaction of the ultrasound system proper and tissue is necessary. This requires the creation of detailed models of both the ultrasound imaging system and tissue. These models enable us to obtain quantitative information about tissue, by examining features of backscattered data, generated by the interaction of the ultrasonic imaging system with the tissue under examination. Imaging systems are typically designed with little consideration of the constraints of the imaging environment or the acoustic features of the tissue which include impedance, scatterer size, shape and density. We propose to take into account the physical properties of tissue in designing ultrasonic imaging arrays. We develop a framework for designing ultrasonic imaging systems (primarily the transducer and transducer array) with physical parameters that are tuned to detect specific features of tissue. The design methodology obtains the parameters of an NxN transducer array constrained to a size of e.g. 2mm x 2mm (the size required for medical imaging). The physical parameters of the transducer elements are also obtained for capacitive micromachined ultrasonic transducer (cMUT) technology. In addition to the overall size constraints (2 mm x 2 mm), several other constraints put limitation upon the possible system

  15. Microinterferometer transducer

    International Nuclear Information System (INIS)

    Steger, P.J.

    1978-01-01

    An air-bearing microinterferometer transducer is being developed to provide for increased accuracy, range, and linearity over conventional linear variable differential transformer (LVDT) transducers. The conventional LVDT's are used on multiple-probe sweep gauges to measure deviation from true surfaces of revolution. These LVDT transducers are null devices, and their high accuracy deteriorates rapidly as they move from zero setting. It is desirable to have a transducer with extended range to measure parts that deviate from conventional paths. The length-measuring interferometer is a well-established inspection device. However, constructing a microinterferometer that will fit inside a conventional 1/2-in. o.d transducer housing is a formidable task. Departure from the conventional interferometer construction is required. It will be necessary to transmit the laser beam into the microinterferometer with a self-focusing fiber optic cable. Miniature glassware has been obtained and a microinterferometer constructed inside a 0.315-in. i.d transducer. Fringes have been obtained by directing a laser beam into the transducer housing

  16. Capacitive pressure transducer using flexible films. Junan film wo mochiita seiden yoryoshiki atsukaku transducer

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Y.; Tsuchida, N.; Imai, K. (Toyota Technological Institute, Aichi (Japan)); Fujita, K. (Nitto Denko Corp., Osaka (Japan)): Tsuboi, O. (Fujitsu Corp., Tokyo (Japan))

    1992-12-20

    This paper describes the design, manufacture, and evaluation of a capacitive pressure transducer made of polyimide films. The structure of a pressure transducer cell was first determined, and then, the deflection-stress and capacitance-load characteristics of the surface film were analyzed using finite element methods. For the practical stage of manufacture, a polyimide film was emboss processed and electrodes were deposited on the film to construct a pressure transducer cell to which a Schmidt-trigger detecting circuit was connected. As a consequence of the examination of operational characteristics of the cell, it was found that the actual relation between the deflection and load approximately agreed with the linear analyses, and that the capacitance depended with little hysteresis on the gap regardless of the native visco-elasticity of the film. Furthermore, small stick-slip vibration of a contact rubber surface was detected by the transducer to verify its high sensitivity. 17 refs., 18 figs.

  17. The design of a focused ultrasound transducer array for the treatment of stroke: a simulation study

    International Nuclear Information System (INIS)

    Pajek, Daniel; Hynynen, Kullervo

    2012-01-01

    High intensity focused ultrasound (HIFU) is capable of mechanically disintegrating blood clots at high pressures. Safe thrombolysis may require frequencies higher than those currently utilized by transcranial HIFU. Since the attenuation and focal distortion of ultrasound in bone increases at higher frequencies, resulting focal pressures are diminished. This study investigated the feasibility of using transcranial HIFU for the non-invasive treatment of ischemic stroke. The use of large aperture, 1.1–1.5 MHz phased arrays in targeting four clinically relevant vessel locations was simulated. Resulting focal sizes decreased with frequency, producing a maximum –3 dB depth of field and lateral width of 2.0 and 1.2 mm, respectively. Mean focal gains above an order of magnitude were observed in three of four targets and transducer intensities required to achieve thrombolysis were determined. Required transducer element counts are about an order of magnitude higher than what currently exists and so, although technically feasible, new arrays would need to be developed to realize this as a treatment modality for stroke. (paper)

  18. Coaxial Transducer

    National Research Council Canada - National Science Library

    Ruffa, Anthony A

    2008-01-01

    The invention as disclosed is of a coaxial transducer that uses lead zirconate titanate ceramic or other suitable material as an isolator between the conductors in a coaxial cable to transmit acoustic...

  19. Design of a titering assay for lentiviral vectors utilizing direct extraction of DNA from transduced cells in microtiter plates

    Directory of Open Access Journals (Sweden)

    Michele E Murphy

    2016-01-01

    Full Text Available Using lentiviral vector products in clinical applications requires an accurate method for measuring transduction titer. For vectors lacking a marker gene, quantitative polymerase chain reaction is used to evaluate the number of vector DNA copies in transduced target cells, from which a transduction titer is calculated. Immune Design previously described an integration-deficient lentiviral vector pseudotyped with a modified Sindbis virus envelope for use in cancer immunotherapy (VP02, of the ZVex platform. Standard protocols for titering integration-competent lentiviral vectors employ commercial spin columns to purify vector DNA from transduced cells, but such columns are not optimized for isolation of extrachromosomal (nonintegrated DNA. Here, we describe a 96-well transduction titer assay in which DNA extraction is performed in situ in the transduction plate, yielding quantitative recovery of extrachromosomal DNA. Vector titers measured by this method were higher than when commercial spin columns were used for DNA isolation. Evaluation of the method's specificity, linear range, and precision demonstrate that it is suitable for use as a lot release assay to support clinical trials with VP02. Finally, the method is compatible with titering both integrating and nonintegrating lentiviral vectors, suggesting that it may be used to evaluate the transduction titer for any lentiviral vector.

  20. Transducer fundamentals

    NARCIS (Netherlands)

    Regtien, Paulus P.L.; Sydenham, Peter H.; Thorn, Richard

    2005-01-01

    A transducer is an essential part of any information process- ing system that operates in more than one physical domain. These domains are characterized by the type of quantity that provides the carrier of the relevant information. Exam- ples are the optical, electrical, mechanical, and magnetic

  1. Designing a Stress Management Curiculum.

    Science.gov (United States)

    Crawford, Michael E.

    1982-01-01

    Educators must develop, for therapeutic recreation students, curriculum that teaches stress management techniques and theories. Guidelines for curriculum revision or enhancement in this area are presented. (CJ)

  2. Practical stress analysis in engineering design

    CERN Document Server

    Huston, Ronald

    2008-01-01

    Presents the application of engineering design and analysis based on the approach of understanding the physical characteristics of a given problem and then modeling the important aspects of the physical system. This book covers such topics as contact stress analysis, singularity functions, gear stresses, fasteners, shafts, and shaft stresses.

  3. Calibration of Underwater Sound Transducers

    OpenAIRE

    H.R.S. Sastry

    1983-01-01

    The techniques of calibration of underwater sound transducers for farfield, near-field and closed environment conditions are reviewed in this paper .The design of acoustic calibration tank is mentioned. The facilities available at Naval Physical & Oceanographic Laboratory, Cochin for calibration of transducers are also listed.

  4. Design and Implementation of a Prototype with a Standardized Interface for Transducers in Ambient Assisted Living

    Directory of Open Access Journals (Sweden)

    Enrique Dorronzoro

    2015-01-01

    Full Text Available Solutions in the field of Ambient Assisted Living (AAL do not generally use standards to implement a communication interface between sensors and actuators. This makes these applications isolated solutions because it is so difficult to integrate them into new or existing systems. The objective of this research was to design and implement a prototype with a standardized interface for sensors and actuators to facilitate the integration of different solutions in the field of AAL. Our work is based on the roadmap defined by AALIANCE, using motes with TinyOS telosb, 6LoWPAN, sensors, and the IEEE 21451 standard protocol. This prototype allows one to upgrade sensors to a smart status for easy integration with new applications and already existing ones. The prototype has been evaluated for autonomy and performance. As a use case, the prototype has been tested in a serious game previously designed for people with mobility problems, and its advantages and disadvantages have been analysed.

  5. Design of a Matrix Transducer for Three-Dimensional Second Harmonic Transesophageal Echocardiography

    Science.gov (United States)

    Blaak, Sandra; van Neer, Paul L. M. J.; Prins, Christian; Bosch, Johan G.; Lancée, Charles T.; van der Steen, Antonius F. W.; de Jong, Nico

    Three-dimensional (3D) echocardiography visualizes the 3D anatomy and function of the heart. For 3D imaging an ultrasound matrix of several thousands of elements is required. To connect the matrix to an external imaging system, smart signal processing with integrated circuitry in the tip of the TEE probe is required for channel reduction. To separate the low voltage integrated receive circuitry from the high voltages required for transmission, our design features a separate transmit and receive subarray. In this study we focus on the transmit subarray. A 3D model of an individual element was developed using the finite element method (FEM). The model was validated by laser interferometer and acoustic measurements. Measurement and simulations matched well. The maximum transmit transfer was 3 nm/V at 2.4 MHz for both the FEM simulation of an element in air and the laser interferometer measurement. The FEM simulation of an element in water resulted in a maximum transfer of 43 kPa/V at 2.3 MHz and the acoustic measurement in 55 kPa/V at 2.5 MHz. The maximum pressure is ~1 MPa/120Vpp, which is sufficient pressure for second harmonic imaging. The proposed design of the transmit subarray is suitable for its role in a 3D 2H TEE probe.

  6. Magnetoelastic Generator Type Transducer

    Directory of Open Access Journals (Sweden)

    A. K. Efremov

    2014-01-01

    Full Text Available Some issues relating to usage of magnetoelectric generator type transducers as the means of measuring intense dynamic loads and as a sensitive element of fuse contact target sensor (CTS are considered. Particular attention is paid to the magnetoanisotropic transducer (MAT, the principle of operation of which is based on the change of the magnetic field form caused by the applied mechanical load leading to the appearance of EMF in the output winding. The MAT, especially monolithic, has such advantages as high strength, reliability, endurance and design simplicity.The functional transducer schemes have been analyzed and for the first time it was shown that there is a possibility of using a version with only one output winding arranged in the magnetic conductor made of magnetically soft material such as structural steel. A mathematical model of transducer is proposed showing that the input signal formed by the external load is proportional to its derivative. With a sufficiently large time constant of the electric circuit and the implementation of a number of additional conditions the transducer may function as an integrator. By that it becomes possible to measure the parameters of dynamic processes having the duration of a few to tens of microseconds. Unlike the traditional transducers such as piezoelectric the output signal is not “masked” by the natural oscillations.The mechanism of the generator effect was considered leading to the “piezomagnetodynamic” model, which includes a number of phenomenological parameters. Some corresponding experimentally derived hysteresis curves are presented. Their vertical shift quantifies the generator effect and does not depend on the intensity of the magnetic field.As an example of practical application of the MAT some results of evaluation of the dynamic force characteristic of the heading part of a piezoelectric fuse are presented. The MAT was also used for the evaluation of back effects of the bullet

  7. Numerical transducer modelling

    DEFF Research Database (Denmark)

    Cutanda, Vicente

    1999-01-01

    Numerical modelling is of importance for the design, improvement and study of acoustic transducers such as microphones and accelerometers. Techniques like the boundary element method and the finite element method are the most common supplement to the traditional empirical and analytical approaches...... errors and instabilities in the computations of numerical solutions. An investigation to deal with this narrow-gap problem has been carried out....

  8. Restraint stress increases prolactin-mediated phosphorylation of signal transducer and activator of transcription 5 in the hypothalamus and adrenal cortex in the male mouse.

    Science.gov (United States)

    Kirk, S E; Xie, T Y; Steyn, F J; Grattan, D R; Bunn, S J

    2017-06-01

    Prolactin is a pleiotropic peptide hormone produced by the lactotrophs in the anterior pituitary. Its rate of secretion is primarily regulated by a negative-feedback mechanism where prolactin stimulates the activity of the tuberoinfundibular dopaminergic (TIDA) neurones, increasing their release of dopamine, which accesses the pituitary via the median eminence to suppress further prolactin secretion. In addition to its well established role in lactation, circulating prolactin is secreted in response to stress, although the mechanism by which this is achieved or its cellular targets remains unknown. In the present study, we show that 15 minutes of restraint stress causes an approximately seven-fold increase in circulating prolactin concentration in male mice. Monitoring prolactin receptor activation, using immunohistochemistry to determine the level and distribution of tyrosine phosphorylated signal transducer and activator of transcription 5 (pSTAT5), we show that this stress-induced increase in prolactin interacts with both central and peripheral targets. Restraint stress for 15 minutes significantly increased pSTAT5 staining in the arcuate nucleus, median eminence and the zona fasciculata of the adrenal cortex. In each case, this response was prevented by pretreating the animals with bromocriptine to block prolactin secretion from the pituitary. Interestingly, in contrast to many cells in the arcuate nucleus, stress reduced pSTAT5 staining of the TIDA neurones (identified by dual-labelling for tyrosine hydroxylase). This suggests that there is reduced prolactin signalling in these cells and thus potentially a decline in their inhibitory influence on prolactin secretion. These results provide evidence that prolactin secreted in response to acute stress is sufficient to activate prolactin receptors in selected target tissues known to be involved in the physiological adaptation to stress. © 2017 British Society for Neuroendocrinology.

  9. Transducers and arrays for underwater sound

    CERN Document Server

    Butler, John L

    2016-01-01

    This improved and updated second edition covers the theory, development, and design of electro-acoustic transducers for underwater applications. This highly regarded text discusses the basics of piezoelectric and magnetostrictive transducers that are currently being used as well as promising new designs. It presents the basic acoustics as well as the specific acoustics data needed in transducer design and evaluation. A broad range of designs of projectors and hydrophones are described in detail along with methods of modeling, evaluation, and measurement. Analysis of projector and hydrophone transducer arrays, including the effects of mutual radiation impedance and numerical models for elements and arrays, are also covered. The book includes new advances in transducer design and transducer materials and has been completely reorganized to be suitable for use as a textbook, as well as a reference or handbook. The new edition contains updates to the first edition, end-of-chapter exercises, and solutions to select...

  10. Stress analysis of the LOFT Modular DTT flowmeter for LOCE transients (L1-5 and L2-4). [Drag disc turbine transducer

    Energy Technology Data Exchange (ETDEWEB)

    Mosby, W.R.

    1978-03-03

    This report presents the results of a stress analysis of the LOFT Modular Drag Disc Turbine Transducer (MDTT). Loading conditions considered included steady-state frontal and transverse fluid dynamic pressure, alternating transverse pressure due to vortex shedding, and thermal expansion loads. Ten different meter locations in the LOFT cooling system were considered for nuclear LOCE's (L2-4) and one location for non-nuclear LOCE L1-5. Stresses were found to be within allowables defined by Section III of the ASME Boiler and Pressure Vessel Code, 1977 Edition, Subsection NB (Class 1), where applicable. In order to maintain good engineering practices for torquing small screws, the specified torquing values for the screws inside the MDTT body are set at values which exceed the non-applicable stress requirements of Class 1 components in Section III of the ASME Boiler and Pressure Vessel Code. In the unlikely event of failure of these screws, no possible damage to the primary coolant system could occur since the screws would remain captured inside the MDTT body.

  11. Coalgebraising subsequential transducers

    NARCIS (Netherlands)

    H.H. Hansen (Helle); J. Adamek; C.A. Kupke (Clemens)

    2008-01-01

    htmlabstractSubsequential transducers generalise both classic deterministic automata and Mealy/Moore type state machines by combining (input) language recognition with transduction. In this paper we show that normalisation and taking differentials of subsequential transducers and their underlying

  12. Coalgebraising Subsequential Transducers

    NARCIS (Netherlands)

    Hansen, H.H.

    2008-01-01

    Subsequential transducers generalise both classic deterministic automata and Mealy/Moore type state machines by combining (input) language recognition with transduction. In this paper we show that normalisation and taking differentials of subsequential transducers and their underlying structures can

  13. A new transducer for local load measurements of friction and roll pressure in cold flat rolling

    DEFF Research Database (Denmark)

    Lagergren, J.; Wanheim, Tarras; Precz, W.

    2006-01-01

    The only way to establish the true rolling pressure and the true friction condition in cold rolling is to conduct measurements in the roll bite. A new transducer design is therefore proposed, in order to overcome problems in previous measurements in the past 70 years. The new idea is to increase...... the contact surface of the transducer, to be larger than the arc of contact. This is in contrast to the smaller and smaller contact pin design that has been prevailing. The measurements were conducted during cold dry rolling of both copper strips and stainless steel strips in a pilot mill. The recordings were...... selected from a steady state with no disturbance from the material flow. The transducer was able to simultaneously measure both the normal pressure and the friction stress. An estimation of the coefficient of friction was accordingly performed. The new transducer works very well, it was seen to be robust...

  14. Driving electrostatic transducers

    DEFF Research Database (Denmark)

    Nielsen, Dennis; Knott, Arnold; Andersen, Michael A. E.

    2013-01-01

    Electrostatic transducers represent a very interesting alternative to the traditional inefficient electrodynamic transducers. In order to establish the full potential of these transducers, power amplifiers which fulfill the strict requirements imposed by such loads (high impedance, frequency...... depended, nonlinear and high bias voltage for linearization) must be developed. This paper analyzes power stages and bias configurations suitable for driving an electrostatic transducer. Measurement results of a 300 V prototype amplifier are shown. Measuring THD across a high impedance source is discussed...

  15. Macro tree transducers

    NARCIS (Netherlands)

    Engelfriet, Joost; Vogler, Heiko

    1985-01-01

    Macro tree transducers are a combination of top-down tree transducers and macro grammars. They serve as a model for syntax-directed semantics in which context information can be handled. In this paper the formal model of macro tree transducers is studied by investigating typical automata theoretical

  16. Objective assessment and design improvement of a staring, sparse transducer array by the spatial crosstalk matrix for 3D photoacoustic tomography.

    Directory of Open Access Journals (Sweden)

    Philip Wong

    Full Text Available Accurate reconstruction of 3D photoacoustic (PA images requires detection of photoacoustic signals from many angles. Several groups have adopted staring ultrasound arrays, but assessment of array performance has been limited. We previously reported on a method to calibrate a 3D PA tomography (PAT staring array system and analyze system performance using singular value decomposition (SVD. The developed SVD metric, however, was impractical for large system matrices, which are typical of 3D PAT problems. The present study consisted of two main objectives. The first objective aimed to introduce the crosstalk matrix concept to the field of PAT for system design. Figures-of-merit utilized in this study were root mean square error, peak signal-to-noise ratio, mean absolute error, and a three dimensional structural similarity index, which were derived between the normalized spatial crosstalk matrix and the identity matrix. The applicability of this approach for 3D PAT was validated by observing the response of the figures-of-merit in relation to well-understood PAT sampling characteristics (i.e. spatial and temporal sampling rate. The second objective aimed to utilize the figures-of-merit to characterize and improve the performance of a near-spherical staring array design. Transducer arrangement, array radius, and array angular coverage were the design parameters examined. We observed that the performance of a 129-element staring transducer array for 3D PAT could be improved by selection of optimal values of the design parameters. The results suggested that this formulation could be used to objectively characterize 3D PAT system performance and would enable the development of efficient strategies for system design optimization.

  17. Micromachined Ultrasonic Transducers for 3-D Imaging

    DEFF Research Database (Denmark)

    Christiansen, Thomas Lehrmann

    of state-of-the-art 3-D ultrasound systems. The focus is on row-column addressed transducer arrays. This previously sparsely investigated addressing scheme offers a highly reduced number of transducer elements, resulting in reduced transducer manufacturing costs and data processing. To produce...... such transducer arrays, capacitive micromachined ultrasonic transducer (CMUT) technology is chosen for this project. Properties such as high bandwidth and high design flexibility makes this an attractive transducer technology, which is under continuous development in the research community. A theoretical...... capable of producing 62+62-element row-column addressed CMUT arrays with negligible charging issues. The arrays include an integrated apodization, which reduces the ghost echoes produced by the edge waves in such arrays by 15:8 dB. The acoustical cross-talk is measured on fabricated arrays, showing a 24 d...

  18. Design Criteria for Controlling Stress Corrosion Cracking

    Science.gov (United States)

    Franklin, D. B.

    1987-01-01

    This document sets forth the criteria to be used in the selection of materials for space vehicles and associated equipment and facilities so that failure resulting from stress corrosion will be prevented. The requirements established herein apply to all metallic components proposed for use in space vehicles and other flight hardware, ground support equipment, and facilities for testing. These requirements are applicable not only to items designed and fabricated by MSFC (Marshall Space Flight Center) and its prime contractors, but also to items supplied to the prime contractor by subcontractors and vendors.

  19. Numerical Transducer Modeling

    DEFF Research Database (Denmark)

    Henriquez, Vicente Cutanda

    This thesis describes the development of a numerical model of the propagation of sound waves in fluids with viscous and thermal losses, with application to the simulation of acoustic transducers, in particular condenser microphones for measurement. The theoretical basis is presented, numerical...... tools and implementation techniques are described and performance tests are carried out. The equations that govern the motion of fluids with losses and the corresponding boundary conditions are reduced to a form that is tractable for the Boundary Element Method (BEM) by adopting some hypotheses...... that are allowable in this case: linear variations, absence of flow, harmonic time variation, thermodynamical equilibrium and physical dimensions much larger than the molecular mean free path. A formulation of the BEM is also developed with an improvement designed to cope with the numerical difficulty associated...

  20. Handbook of force transducers

    CERN Document Server

    Stefanescu, Dan Mihai

    2011-01-01

    Part I introduces the basic ""Principles and Methods of Force Measurement"" acording to a classification into a dozen of force transducers types: resistive, inductive, capacitive, piezoelectric, electromagnetic, electrodynamic, magnetoelastic, galvanomagnetic (Hall-effect), vibrating wires, (micro)resonators, acoustic and gyroscopic. Two special chapters refer to force balance techniques and to combined methods in force measurement. Part II discusses the ""(Strain Gauge) Force Transducers Components"", evolving from the classical force transducer to the digital / intelligent one, with the inco

  1. Driving electrostatic transducers

    DEFF Research Database (Denmark)

    Nielsen, Dennis; Knott, Arnold; Andersen, Michael A. E.

    2013-01-01

    Electrostatic transducers represent a very interesting alternative to the traditional inefficient electrodynamic transducers. In order to establish the full potential of these transducers, power amplifiers which fulfill the strict requirements imposed by such loads (high impedance, frequency...... depended, nonlinear and high bias voltage for linearization) must be developed. This paper analyzes power stages and bias configurations suitable for driving an electrostatic transducer. Measurement results of a 300 V prototype amplifier are shown. Measuring THD across a high impedance source is discussed......, and a high voltage attenuation interface for an audio analyzer is presented. THD below 0:1% is reported....

  2. Programming macro tree transducers

    DEFF Research Database (Denmark)

    Bahr, Patrick; Day, Laurence E.

    2013-01-01

    A tree transducer is a set of mutually recursive functions transforming an input tree into an output tree. Macro tree transducers extend this recursion scheme by allowing each function to be defined in terms of an arbitrary number of accumulation parameters. In this paper, we show how macro tree ...

  3. Failure Analysis of High-Power Piezoelectric Transducers

    National Research Council Canada - National Science Library

    Gabrielson, T. B

    2005-01-01

    ... and stress in a piezoelectric material. For a transducer operated near resonance, there will be "hot spots" or regions of locally intense stress and electric field that precipitate premature failure...

  4. A new transducer for local load measurements of friction and roll pressure in cold flat rolling

    DEFF Research Database (Denmark)

    Lagergren, J.; Wanheim, Tarras; Precz, W.

    2006-01-01

    selected from a steady state with no disturbance from the material flow. The transducer was able to simultaneously measure both the normal pressure and the friction stress. An estimation of the coefficient of friction was accordingly performed. The new transducer works very well, it was seen to be robust......The only way to establish the true rolling pressure and the true friction condition in cold rolling is to conduct measurements in the roll bite. A new transducer design is therefore proposed, in order to overcome problems in previous measurements in the past 70 years. The new idea is to increase...... and able to avoid signal disturbance. The pressure and friction stress distribution results was as expected by the authors and showed good reproducibility, together with a proven agreement between recorded and simulated signals....

  5. Contact Stress Design Parameters for Titanium Bearings, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Air-Lock's Phase I effort tested the effects of ball induced contact stresses on Titanium bearing races. The contact stress design limit that would achieve a...

  6. Design and implementation of improved LsCpLp resonant circuit for power supply for high-power electromagnetic acoustic transducer excitation

    Science.gov (United States)

    Zao, Yongming; Ouyang, Qi; Chen, Jiawei; Zhang, Xinglan; Hou, Shuaicheng

    2017-08-01

    This paper investigates the design and implementation of an improved series-parallel inductor-capacitor-inductor (LsCpLp) resonant circuit power supply for excitation of electromagnetic acoustic transducers (EMATs). The main advantage of the proposed resonant circuit is the absence of a high-permeability dynamic transformer. A high-frequency pulsating voltage gain can be achieved through a double resonance phenomenon. Both resonant tailing behavior and higher harmonics are suppressed by the improved resonant circuit, which also contributes to the generation of ultrasonic waves. Additionally, the proposed circuit can realize impedance matching and can also optimize the transduction efficiency. The complete design and implementation procedure for the power supply is described and has been validated by implementation of the proposed power supply to drive a portable EMAT. The circuit simulation results show close agreement with the experimental results and thus confirm the validity of the proposed topology. The proposed circuit is suitable for use as a portable EMAT excitation power supply that is fed by a low-voltage source.

  7. Design and implementation of improved LsCpLp resonant circuit for power supply for high-power electromagnetic acoustic transducer excitation.

    Science.gov (United States)

    Zao, Yongming; Ouyang, Qi; Chen, Jiawei; Zhang, Xinglan; Hou, Shuaicheng

    2017-08-01

    This paper investigates the design and implementation of an improved series-parallel inductor-capacitor-inductor (L s C p L p ) resonant circuit power supply for excitation of electromagnetic acoustic transducers (EMATs). The main advantage of the proposed resonant circuit is the absence of a high-permeability dynamic transformer. A high-frequency pulsating voltage gain can be achieved through a double resonance phenomenon. Both resonant tailing behavior and higher harmonics are suppressed by the improved resonant circuit, which also contributes to the generation of ultrasonic waves. Additionally, the proposed circuit can realize impedance matching and can also optimize the transduction efficiency. The complete design and implementation procedure for the power supply is described and has been validated by implementation of the proposed power supply to drive a portable EMAT. The circuit simulation results show close agreement with the experimental results and thus confirm the validity of the proposed topology. The proposed circuit is suitable for use as a portable EMAT excitation power supply that is fed by a low-voltage source.

  8. Multi Resonance Shear Mode Transducers

    Science.gov (United States)

    2016-11-21

    engineering in the single crystal lead magnesium niobate-lead titanate (PMNT) system has uncovered a very unique piezoelectric shear mode. Contrary to...ABSTRACT Crystallographic engineering of single crystal relaxor-based ferroelectrics was used to design broadband, compact, high power, low frequency...utilize the d36 shear piezoelectric coefficient, which has advantages for compact low frequency sonar transducers. The d36 cut is unique in that large

  9. Design of a PC Based Pressure Indicator Using Inductive Pick-up Type Transducer and Bourdon Tube Sensor

    Directory of Open Access Journals (Sweden)

    S. C. BERA

    2009-08-01

    Full Text Available Bourdon tube is a mechanical type pressure sensor and the bourdon gauge measures gauge pressure of a process pipe line or a process tank. But it is a local indicator and special costlier techniques are required to transmit the reading of bourdon gauge to a remote distance. In the present paper, a very simple inductive pick-up type technique has been developed to transmit the reading of bourdon gauge to a remote distance in the form of 1-5 Volt D.C. signal. This signal has been optically isolated to design a PC based pressure indicator using Labtech Note Book Pro software. The theoretical analysis of the whole technique has been presented in the paper. The instrument developed using this technique has been experimentally tested and the experimental results are reported in the paper. A good linearity and repeatability of the instrument has been observed.

  10. Smart transducer with radiomodem

    Science.gov (United States)

    Pugach, V. N.; Voronin, E. L.

    2018-04-01

    Systems for measuring different parameters enabling metering and wireless data transmission are an urgent problem in the industry. One of the most promising solutions is the developments of metering instruments enabling radio-link and GSM data transmission. The article describes a transducer operating with temperature sensors of different types as well as with the sensors of other physical values with the output signal represented as current or voltage with subsequent measurement data transmission from the transducer to the computer via radio-link. The article provides transducer measurement accuracy check. The work confirmed the claimed temperature measurement accuracy, noted a stable data transmission via radio link and convenience of work with the transducer and software.

  11. Pressure Transducer Locations

    Data.gov (United States)

    National Aeronautics and Space Administration — Files are located here, defining the locations of the pressure transducers on the HIRENASD model. These locations also correspond to the locations that analysts...

  12. Micromachined silicon seismic transducers

    Energy Technology Data Exchange (ETDEWEB)

    Barron, C.C.; Fleming, J.G.; Sniegowski, J.J.; Armour, D.L.; Fleming, R.P.

    1995-08-01

    Batch-fabricated silicon seismic transducers could revolutionize the discipline of CTBT monitoring by providing inexpensive, easily depolyable sensor arrays. Although our goal is to fabricate seismic sensors that provide the same performance level as the current state-of-the-art ``macro`` systems, if necessary one could deploy a larger number of these small sensors at closer proximity to the location being monitored in order to compensate for lower performance. We have chosen a modified pendulum design and are manufacturing prototypes in two different silicon micromachining fabrication technologies. The first set of prototypes, fabricated in our advanced surface- micromachining technology, are currently being packaged for testing in servo circuits -- we anticipate that these devices, which have masses in the 1--10 {mu}g range, will resolve sub-mG signals. Concurrently, we are developing a novel ``mold`` micromachining technology that promises to make proof masses in the 1--10 mg range possible -- our calculations indicate that devices made in this new technology will resolve down to at least sub-{mu}G signals, and may even approach to 10{sup {minus}10} G/{radical}Hz acceleration levels found in the low-earth-noise model.

  13. Digital electrostatic acoustic transducer array

    KAUST Repository

    Carreno, Armando Arpys Arevalo

    2016-12-19

    In this paper we present the fabrication and characterization of an array of electrostatic acoustic transducers. The array is micromachined on a silicon wafer using standard micro-machining techniques. Each array contains 2n electrostatic transducer membranes, where “n” is the bit number. Every element of the array has a hexagonal membrane shape structure, which is separated from the substrate by 3µm air gap. The membrane is made out 5µm thick polyimide layer that has a bottom gold electrode on the substrate and a gold top electrode on top of the membrane (250nm). The wafer layout design was diced in nine chips with different array configurations, with variation of the membrane dimensions. The device was tested with 90 V giving and sound output level as high as 35dB, while actuating all the elements at the same time.

  14. Ultrasonic properties of all-printed piezoelectric polymer transducers

    Science.gov (United States)

    Wagle, Sanat; Decharat, Adit; Bodö, Peter; Melandsø, Frank

    2013-12-01

    The ability of producing ultrasonic transducers from screen-printing has been explored experimentally, through printing and characterization of a large number of transducers. In an all-printed test design, 124 transducers with four different electrode sizes ranging from 1 to 4.9 mm2, were printed layer-by-layer on a high performance polyethyleneimine polymer. Inks from ferroelectric and conductive polymers were applied to the active part of a transducer, to provide a good acoustical match between the individual layers. Ultrasonic characterizations of the transducers done by two independent methods provided a broad-banded frequency response with a maximum response around 100 MHz.

  15. Stress-constrained topology optimization for compliant mechanism design

    DEFF Research Database (Denmark)

    de Leon, Daniel M.; Alexandersen, Joe; Jun, Jun S.

    2015-01-01

    This article presents an application of stress-constrained topology optimization to compliant mechanism design. An output displacement maximization formulation is used, together with the SIMP approach and a projection method to ensure convergence to nearly discrete designs. The maximum stress...... is approximated using a normalized version of the commonly-used p-norm of the effective von Mises stresses. The usual problems associated with topology optimization for compliant mechanism design: one-node and/or intermediate density hinges are alleviated by the stress constraint. However, it is also shown...

  16. Handbook of force transducers. Principles and components

    Energy Technology Data Exchange (ETDEWEB)

    Stefanescu, Dan Mihai [Romanian Measurement Society, Bucharest (Romania)

    2011-07-01

    Part I introduces the basic ''Principles and Methods of Force Measurement'' according to a classification into a dozen of force transducers types: resistive, inductive, capacitive, piezoelectric, electromagnetic, electrodynamic, magnetoelastic, galvanomagnetic (Hall-effect), vibrating wires, (micro)resonators, acoustic and gyroscopic. Two special chapters refer to force balance techniques and to combined methods in force measurement. Part II discusses the ''(Strain Gauge) Force Transducers Components'', evolving from the classical force transducer to the digital / intelligent one, with the incorporation of three subsystems (sensors, electromechanics and informatics). The elastic element (EE) is the ''heart'' of the force transducer and basically determines its performance. A 12-type elastic element classification is proposed (stretched / compressed column or tube, bending beam, bending and/or torsion shaft, middle bent bar with fixed ends, shear beam, bending ring, yoke or frame, diaphragm, axial-stressed torus, axisymmetrical and voluminous EE), with emphasis on the optimum location of the strain gauges. The main properties of the associated Wheatstone bridge, best suited for the parametrical transducers, are examined, together with the appropriate electronic circuits for SGFTs. The handbook fills a gap in the field of Force Measurement, both experts and newcomers, no matter of their particular interest, finding a lot of useful and valuable subjects in the area of Force Transducers; in fact, it is the first specialized monograph in this inter- and multidisciplinary field. (orig.)

  17. Analysis of binary mixtures of aqueous aromatic hydrocarbons with low-phase-noise shear-horizontal surface acoustic wave sensors using multielectrode transducer designs.

    Science.gov (United States)

    Bender, Florian; Mohler, Rachel E; Ricco, Antonio J; Josse, Fabien

    2014-11-18

    The present work investigates a compact sensor system that provides rapid, real-time, in situ measurements of the identities and concentrations of aromatic hydrocarbons at parts-per-billion concentrations in water through the combined use of kinetic and thermodynamic response parameters. The system uses shear-horizontal surface acoustic wave (SH-SAW) sensors operating directly in the liquid phase. The 103 MHz SAW sensors are coated with thin sorbent polymer films to provide the appropriate limits of detection as well as partial selectivity for the analytes of interest, the BTEX compounds (benzene, toluene, ethylbenzene, and xylenes), which are common indicators of fuel and oil accidental releases in groundwater. Particular emphasis is placed on benzene, a known carcinogen and the most challenging BTEX analyte with regard to both regulated levels and its solubility properties. To demonstrate the identification and quantification of individual compounds in multicomponent aqueous samples, responses to binary mixtures of benzene with toluene as well as ethylbenzene were characterized at concentrations below 1 ppm (1 mg/L). The use of both thermodynamic and kinetic (i.e., steady-state and transient) responses from a single polymer-coated SH-SAW sensor enabled identification and quantification of the two BTEX compounds in binary mixtures in aqueous solution. The signal-to-noise ratio was improved, resulting in lower limits of detection and improved identification at low concentrations, by designing and implementing a type of multielectrode transducer pattern, not previously reported for chemical sensor applications. The design significantly reduces signal distortion and root-mean-square (RMS) phase noise by minimizing acoustic wave reflections from electrode edges, thus enabling limits of detection for BTEX analytes of 9-83 ppb (calculated from RMS noise); concentrations of benzene in water as low as ~100 ppb were measured directly. Reliable quantification of BTEX

  18. Calculations for piezoelectric ultrasonic transducers

    International Nuclear Information System (INIS)

    Jensen, H.

    1986-05-01

    Analysis of piezoelectric ultrasonic transducers implies a solution of a boundary value problem, for a body which consists of different materials, including a piezoelectric part. The problem is dynamic at frequencies, where a typical wavelength is somewhat less than the size of the body. Radiation losses as well as internal losses may be important. Due to the complexity of the problem, a closed form solution is the exception rather than the rule. For this reason, it is necessary to use approximate methods for the analysis. Equivalent circuits, the Rayleigh-Ritz method, Mindlin plate theory and in particular the finite element method are considered. The finite element method is utilized for analysis of axisymmetric transducers. An explicit, fully piezoelectric, triangular ring element, with linear variations in displacement and electric potential is given. The influence of a fluid half-space is also given, in the form of a complex stiffness matrix. A special stacking procedure, for analysis of the backing has been developed. This procedure gives a saving, which is similar to that of the fast fourier transform algorithm, and is also wellsuited for analysis of finite and infinite waveguides. Results obtained by the finite element method are shown and compared with measurements and exact solutions. Good agreement is obtained. It is concluded that the finite element method can be a valueable tool in analysis and design of ultrasonic transducers. (author)

  19. Modeling of ultrasound transducers

    DEFF Research Database (Denmark)

    Bæk, David

    deviation of 5.5 % to 11.0 %. Finite element modeling of piezoceramics in combination with Field II is addressed and reveals the influence of restricting the modeling of transducers to the one-dimensional case. An investigation on modeling capacitive micromachined ultrasonic transducers (CMUT)s with Field...... II is addressed. It is shown how a single circular CMUT cell can be well approximated with a simple square transducer encapsulating the cell, and how this influence the modeling of full array elements. An optimal cell discretization with Field II’s mathematical elements is addressed as well....... The error in modeling CMUT cells as squares or flat circular plates instead of curved circular cells is also addressed....

  20. Lumber stress grades and design properties

    Science.gov (United States)

    David E. Kretschmann; David W. Green

    1999-01-01

    Lumber sawn from a log, regardless of species and size, is quite variable in mechanical properties. Pieces may differ in strength by several hundred percent. For simplicity and economy in use, pieces of lumber of similar mechanical properties are placed in categories called stress grades, which are characterized by (a) one or more sorting criteria, (b) a set of...

  1. Vibration transducer calibration techniques

    Science.gov (United States)

    Brinkley, D. J.

    1980-09-01

    Techniques for the calibration of vibration transducers used in the Aeronautical Quality Assurance Directorate of the British Ministry of Defence are presented. Following a review of the types of measurements necessary in the calibration of vibration transducers, the performance requirements of vibration transducers, which can be used to measure acceleration, velocity or vibration amplitude, are discussed, with particular attention given to the piezoelectric accelerometer. Techniques for the accurate measurement of sinusoidal vibration amplitude in reference-grade transducers are then considered, including the use of a position sensitive photocell and the use of a Michelson laser interferometer. Means of comparing the output of working-grade accelerometers with that of previously calibrated reference-grade devices are then outlined, with attention given to a method employing a capacitance bridge technique and a method to be used at temperatures between -50 and 200 C. Automatic calibration procedures developed to speed up the calibration process are outlined, and future possible extensions of system software are indicated.

  2. Transduced space and transvisuality

    DEFF Research Database (Denmark)

    Michelsen, Anders Ib

    2017-01-01

    feeds into the matter of architecture in new ways. On this background, the chapter discusses the ideas behind the drawing material of Architecture, Time and Form as presented in this book, as a relationship between transduced space and transvisual aesthetics. The material of drawing treated in this book...

  3. Design element alternatives for stress-management intervention websites.

    Science.gov (United States)

    Williams, Reg A; Gatien, Gary; Hagerty, Bonnie

    2011-01-01

    Typical public and military-sponsored websites on stress and depression tend to be prescriptive. Some require users to complete lengthy questionnaires. Others reproduce printed flyers, papers, or educational materials not adapted for online use. Some websites require users to follow a prescribed path through the material. Stress Gym was developed as a first-level, evidence-based, website intervention to help U.S. military members learn how to manage mild to moderate stress and depressive symptoms using a self-help intervention with progress tracking and 24/7 availablility. It was designed using web-based, health-management intervention design elements that have been proven effective and users reported they prefer. These included interactivity, self-pacing, and pleasing aesthetics. Users learned how to manage stress by accessing modules they choose, and by practicing proven stress management strategies interactively immediately after login. Test results of Stress Gym with Navy members demonstrated that it was effective, with significant decreases in reported perceived stress levels from baseline to follow-up assessment. Stress Gym used design elements that may serve as a model for future websites to emulate and improve upon, and as a template against which to compare and contrast the design and functionality of future online, health-intervention websites. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Measurement of internal forces in superconducting accelerator magnets with strain gauge transducers

    International Nuclear Information System (INIS)

    Goodzeit, C.L.; Anerella, M.D.; Ganetis, G.L.

    1988-01-01

    An improved method has been developed for the measurement of internal forces in superconducting accelerator magnets, in particular the compressive stresses in coils and the end restraint forces on the coils. The transducers have been designed to provide improved sensitivity to purely mechanical strain by using bending mode deflections for sensing the applied loads. Strain gauge resistance measurements are made with a new system that eliminates sources of errors due to spurious resistance changes in interconnecting wiring and solder joints. The design of the transducers and their measurement system is presented along with a discussion of the method of compensation for thermal and magnetic effects, methods of calibration with typical calibration data, and measured effect in actual magnets of the thermal stress changes from cooldown and the Lorentz forces during magnet excitation. 13 figs., 1 tab

  5. Nano-optomechanical transducer

    Science.gov (United States)

    Rakich, Peter T; El-Kady, Ihab F; Olsson, Roy H; Su, Mehmet Fatih; Reinke, Charles; Camacho, Ryan; Wang, Zheng; Davids, Paul

    2013-12-03

    A nano-optomechanical transducer provides ultrabroadband coherent optomechanical transduction based on Mach-wave emission that uses enhanced photon-phonon coupling efficiencies by low impedance effective phononic medium, both electrostriction and radiation pressure to boost and tailor optomechanical forces, and highly dispersive electromagnetic modes that amplify both electrostriction and radiation pressure. The optomechanical transducer provides a large operating bandwidth and high efficiency while simultaneously having a small size and minimal power consumption, enabling a host of transformative phonon and signal processing capabilities. These capabilities include optomechanical transduction via pulsed phonon emission and up-conversion, broadband stimulated phonon emission and amplification, picosecond pulsed phonon lasers, broadband phononic modulators, and ultrahigh bandwidth true time delay and signal processing technologies.

  6. Piezoelectric transduction of flexural modes in pre-stressed microbeam resonators

    Science.gov (United States)

    Torri, G. B.; Janssen, N. M. A.; Zeng, Z.; Rottenberg, X.; Karabacak, D. M.; Vandecasteele, M.; Van Hoof, C.; Puers, R.; Tilmans, H. A. C.

    2014-08-01

    This paper reports on the optimization of the design of piezoelectric transducer elements integrated on doubly-clamped microbeam resonators utilized as (bio)chemical sensors. We report and emphasize the often forgotten influence of membrane stresses on defining the dimensions and optimal position of the piezoelectric transducer elements. The study takes into account stress induced structural changes and provides models for the equivalent motional parameters of resonators with particular shapes of the transducers matching the flexural modes of vibration. The above is analyzed theoretically using numerical models and is confirmed by impedance measurements and optical measurements of fabricated doubly-clamped beam resonators. We propose various transducer designs and highlight the advantages of using higher order vibration modes by implementing specially designed mode matching transducer elements. It is concluded that the paper describes and highlights the importance of accounting for the membrane stresses to optimize the resonator performance and the low power in electronic feedback of resonating sensing systems.

  7. Three dimensional contact stresses under the LINTRACK wide base single tyres, measured with the Vehicle-Road Surface Pressure Transducer Array (VRSPTA) system in South Africa

    CSIR Research Space (South Africa)

    De Beer, Morris

    1996-11-01

    Full Text Available system at TuDelft and a new tyre, were sent to South Africa for a comprehensive set of contact stress measurements under the South African Heavy Vehicle Simulator (HVS), which was used to provide the loading and speed requirements needed for the stress...

  8. Steerable Doppler transducer probes

    International Nuclear Information System (INIS)

    Fidel, H.F.; Greenwood, D.L.

    1986-01-01

    An ultrasonic diagnostic probe is described which is capable of performing ultrasonic imaging and Doppler measurement consisting of: a hollow case having an acoustic window which passes ultrasonic energy and including chamber means for containing fluid located within the hollow case and adjacent to a portion of the acoustic window; imaging transducer means, located in the hollow case and outside the fluid chamber means, and oriented to direct ultrasonic energy through the acoustic window toward an area which is to be imaged; Doppler transducer means, located in the hollow case within the fluid chamber means, and movably oriented to direct Doppler signals through the acoustic window toward the imaged area; means located within the fluid chamber means and externally controlled for controllably moving the Doppler transducer means to select one of a plurality of axes in the imaged area along which the Doppler signals are to be directed; and means, located external to the fluid chamber means and responsive to the means for moving, for providing an indication signal for identifying the selected axis

  9. Circular cylinders and pressure vessels stress analysis and design

    CERN Document Server

    Vullo, Vincenzo

    2014-01-01

    This book provides comprehensive coverage of stress and strain analysis of circular cylinders and pressure vessels, one of the classic topics of machine design theory and methodology. Whereas other books offer only a partial treatment of the subject and frequently consider stress analysis solely in the elastic field, Circular Cylinders and Pressure Vessels broadens the design horizons, analyzing theoretically what happens at pressures that stress the material beyond its yield point and at thermal loads that give rise to creep. The consideration of both traditional and advanced topics ensures that the book will be of value for a broad spectrum of readers, including students in postgraduate, and doctoral programs and established researchers and design engineers. The relations provided will serve as a sound basis for the design of products that are safe, technologically sophisticated, and compliant with standards and codes and for the development of innovative applications.

  10. Natural fiber composite design and characterization for limit stress prediction in multiaxial stress state

    OpenAIRE

    Christopher C. Ihueze; Christian E. Okafor; Chris I. Okoye

    2015-01-01

    This paper focuses on the design of natural fiber composites and analysis of multiaxial stresses in relation to yield limit stresses of composites loaded off the fibers axis. ASTM D638-10 standard for tensile test was used to design and compose composites of plantain fiber reinforced polyester (PFRP). While the rule of mixtures was used in the evaluation of properties of composites in the fiber direction the evaluation of properties perpendicular or transverse to the fiber direction was done ...

  11. FEM model based optimization of transducer geometry for photoacoustic imaging

    NARCIS (Netherlands)

    Xia, W.; Piras, D.; van Veldhoven, S.; Prins, C; van Leeuwen, Ton; Steenbergen, Wiendelt; Manohar, Srirang

    2012-01-01

    We optimize the design of an ultrasound transducer for photoacoustic breast imaging using FEM analysis. We arrive at a detector design which shows significant improvement in image quality when used in photoacoustic tomographic simulations.

  12. Fiber-optic coupled pressure transducer

    International Nuclear Information System (INIS)

    Tallman, C.R.; Wingate, F.P.; Ballard, E.O.

    1979-01-01

    A fiber-optic coupled pressure transducer was developed for measurement of pressure transients produced by fast electrical discharges in laser cavities. A detailed description of the design and performance will be given. Shock tube performance and measurements in direct electrical discharge regions will be presented

  13. Broadband tonpilz underwater acoustic transducers based on multimode optimization

    DEFF Research Database (Denmark)

    Yao, Qingshan; Jensen, Leif Bjørnø

    1997-01-01

    Head flapping has often been considered to be deleterious for obtaining a tonpilz transducer with broadband, high power performance. In the present work, broadband, high power tonpilz transducers have been designed using the finite element (FE) method. Optimized vibrational modes including the fl...

  14. Rapid prototyping fabrication of focused ultrasound transducers.

    Science.gov (United States)

    Kim, Yohan; Maxwell, Adam D; Hall, Timothy L; Xu, Zhen; Lin, Kuang-Wei; Cain, Charles A

    2014-09-01

    Rapid prototyping (RP) fabrication techniques are currently widely used in diverse industrial and medical fields, providing substantial advantages in development time and costs in comparison to more traditional manufacturing processes. This paper presents a new method for the fabrication of high-intensity focused ultrasound transducers using RP technology. The construction of a large-aperture hemispherical transducer designed by computer software is described to demonstrate the process. The transducer was conceived as a modular design consisting of 32 individually focused 50.8-mm (2-in) PZT-8 element modules distributed in a 300-mm hemispherical scaffold with a geometric focus of 150 mm. The entire structure of the array, including the module housings and the hemispherical scaffold was fabricated through a stereolithography (SLA) system using a proprietary photopolymer. The PZT elements were bonded to the lenses through a quarter-wave tungsten-epoxy matching layer developed in-house specifically for this purpose. Modules constructed in this manner displayed a high degree of electroacoustic consistency, with an electrical impedance mean and standard deviation of 109 ± 10.2 Ω for the 32 elements. Time-of-flight measurements for individually pulsed modules mounted on the hemispherical scaffold showed that all pulses arrived at the focus within a 350 ns range, indicating a good degree of element alignment. Pressure profile measurements of the fully assembled transducer also showed close agreement with simulated results. The measured focal beam FWHM dimensions were 1.9 × 4.0 mm (1.9 × 3.9 mm simulated) in the transversal and axial directions respectively. Total material expenses associated with the construction of the transducer were approximately 5000 USD (as of 2011). The versatility and lower fabrication costs afforded by RP methods may be beneficial in the development of complex transducer geometries suitable for a variety of research and clinical applications.

  15. Piezoelectric transducer array microspeaker

    KAUST Repository

    Carreno, Armando Arpys Arevalo

    2016-12-19

    In this paper we present the fabrication and characterization of a piezoelectric micro-speaker. The speaker is an array of micro-machined piezoelectric membranes, fabricated on silicon wafer using advanced micro-machining techniques. Each array contains 2n piezoelectric transducer membranes, where “n” is the bit number. Every element of the array has a circular shape structure. The membrane is made out four layers: 300nm of platinum for the bottom electrode, 250nm or lead zirconate titanate (PZT), a top electrode of 300nm and a structural layer of 50

  16. Parametric stress analysis of NET first wall designs

    International Nuclear Information System (INIS)

    Cardella, A.; Gorenflo, H.

    1986-01-01

    A parametric stress analysis of NET first wall designs has been performed in order to evaluate the stress levels and distribution due to the thermal loads in operating conditions and to compare the influence of different geometrical parameters. A tight first wall box, enclosing each blanket segment, has been analysed as a first configuration and then compared with a separated first wall panel. Thermal analyses of different first wall cross sections proposed for NET have been carried out to provide guidance for the F.W. design. (author)

  17. Thermoacoustic power conversion using a piezoelectric transducer.

    Science.gov (United States)

    Jensen, Carl; Raspet, Richard

    2010-07-01

    The predicted efficiency of a simple thermoacoustic waste heat power conversion device has been investigated as part of a collaborative effort combining a thermoacoustic engine with a piezoelectric transducer. Symko et al. [Microelectron. J. 35, 185-191 (2004)] at the University of Utah built high frequency demonstration engines for this application, and Lynn [ASMDC report, accession number ADA491030 (2008)] at the University of Washington designed and built a high efficiency piezoelectric unimorph transducer for electroacoustic conversion. The design presented in this paper is put forward to investigate the potential of a simple high frequency, air filled, standing wave thermoacoustic device to be competitive with other small generator technologies such as thermoelectric devices. The thermoacoustic generator is simulated using a low-amplitude approximation for thermoacoustics and the acoustic impedance of the transducer is modeled using an equivalent circuit model calculated from the transducer's mechanical and electrical properties. The calculations demonstrate that a device performance of around 10% of Carnot efficiency could be expected from the design which is competitive with currently available thermoelectric generators.

  18. Platinum and palladium high-temperature transducers on langasite.

    Science.gov (United States)

    Thiele, Jeremy A; da Cunha, Mauricio Pereira

    2005-04-01

    There is a pressing need for the fabrication of surface acoustic wave (SAW) devices capable of operating in harsh environments, at elevated temperature and pressure, or under high-power conditions. These SAW devices operate as frequency-control elements, signal-processing filters, and pressure, temperature, and gas sensors. Applications include gas and oil wells, high-power duplexers in communication systems, and automobile and aerospace combustion engines. Under these high-temperature and power-operating conditions, which can reach several hundred degrees Centigrade, the typically fabricated aluminum (A1) thin film interdigital transducer (IDT) fails due to electro and stress migration. This work reports on high temperature SAW transducers that have been designed, fabricated, and tested on langasite (LGS) piezoelectric substrates. Platinum (Pt) and palladium (Pd) (melting points at 1769 degrees C and 1554.9 degrees C, respectively) have been used as thin metallic films for the SAW IDTs fabricated. Zirconium (Zr) was originally used as an adhesion layer on the fabricated SAW transducers to avoid migration into the Pt or Pd metallic films. The piezoelectric LGS crystal, used as the substrate upon which the SAW devices were fabricated, does not exhibit any phase transition up to its melting point at 1470 degrees C. A radio frequency (RF) test and characterization system capable of withstanding 1000 degrees C has been designed and constructed. The LGS SAW devices with Pt and Pd electrodes and the test system have been exposed to temperatures in the range of 250 degrees C to 750 degrees C over periods up to 6 weeks, with the SAW devices showing a reduced degradation better than 7 dB in the magnitude of transmission coefficient, /S21/, with respect to room temperature. These results qualify the Pt and Pd LGS SAW IDTs fabricated for the above listed modern applications in harsh environments.

  19. Analysis of eigenfrequencies in piezoelectric transducers using the finite element method

    DEFF Research Database (Denmark)

    Jensen, Henrik

    1988-01-01

    It is noted that the finite-element method is a valuable supplement to the traditional methods for design of novel transducer types because it can determine the vibrational pattern of piezoelectric transducers and is applicable to any geometry. Computer programs for analysis of axisymmetric...... transducers, which include the complete set of piezoelectric equations, have been included. They can find eigenfrequencies for undamped transducers and perform forced-response analysis for transducers with internal and radiation damping. The superelement technique is used to model the transducer backing...

  20. Ultrasonic Transducers for Fourier Analysis.

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    1995-01-01

    Describes an experiment that uses the ultrasonic transducer for demonstrating the Fourier components of waveshapes such as the square and triangular waves produced by laboratory function generators. (JRH)

  1. Optically transduced MEMS magnetometer

    Science.gov (United States)

    Nielson, Gregory N; Langlois, Eric

    2014-03-18

    MEMS magnetometers with optically transduced resonator displacement are described herein. Improved sensitivity, crosstalk reduction, and extended dynamic range may be achieved with devices including a deflectable resonator suspended from the support, a first grating extending from the support and disposed over the resonator, a pair of drive electrodes to drive an alternating current through the resonator, and a second grating in the resonator overlapping the first grating to form a multi-layer grating having apertures that vary dimensionally in response to deflection occurring as the resonator mechanically resonates in a plane parallel to the first grating in the presence of a magnetic field as a function of the Lorentz force resulting from the alternating current. A plurality of such multi-layer gratings may be disposed across a length of the resonator to provide greater dynamic range and/or accommodate fabrication tolerances.

  2. Stress relaxation insensitive designs for metal compliant mechanism threshold accelerometers

    Directory of Open Access Journals (Sweden)

    Carlos Vilorio

    2015-12-01

    Full Text Available We present two designs for metal compliant mechanisms for use as threshold accelerometers which require zero external power. Both designs rely on long, thin flexures positioned orthogonally to a flat body. The first design involves cutting or stamping a thin spring-steel sheet and then bending elements to form the necessary thin flexors. The second design uses precut spring-steel flexure elements mounted into a mold which is then filled with molten tin to form a bimetallic device. Accelerations necessary to switch the devices between bistable states were measured using a centrifuge. Both designs showed very little variation in threshold acceleration due to stress relaxation over a period of several weeks. Relatively large variations in threshold acceleration were observed for devices of the same design, most likely due to variations in the angle of the flexor elements relative to the main body of the devices.

  3. Stress concentrations in keyways and optimization of keyway design

    DEFF Research Database (Denmark)

    Pedersen, Niels Leergaard

    2010-01-01

    Keys and keyways are one of the most common shaft–hub connections. Despite this fact very little numerical analysis has been reported. The design is often regulated by standards that are almost half a century old, and most results reported in the literature are based on experimental photoelastic...... analysis. The present paper shows how numerical finite element (FE) analysis can improve the prediction of stress concentration in the keyway. Using shape optimization and the simple super elliptical shape, it is shown that the fatigue life of a keyway can be greatly improved with up to a 50 per cent...... reduction in the maximum stress level. The design changes are simple and therefore practical to realize with only two active design parameters....

  4. The Prediction and Measurement of Acoustic Absorption in High-Temperature (up to 1200 Degrees k) Atmospheric Gas Mixtures, Using a Specially Designed Plate-Diaphragm Capacitive High-Temperature Acoustic Transducer.

    Science.gov (United States)

    George, Wallace Reuben Arthur

    1990-03-01

    This research is an in-depth study of the absorption of acoustic energy by arbitrary gas mixtures of N _2, O_2, CO _2, H_2O, and Ar, at temperatures up to 1200^circK. Special attention is given to vibrational molecular relaxational acoustic absorption. This dissertation consists of three parts. The first is the design and the modeling of the response of a capacitive annular plate-diaphragm High Temperature Acoustic (HTA) transducer. The second is the discussion, modeling, and/or prediction of the acoustic dissipative mechanisms applicable to acoustic propagation in cylindrical ducts. The third aspect of this research involves the measurements of absorption in high temperature (less than 1200^circK) gas mixtures using the High Temperature Acoustic (HTA) transducer and the comparison with predicted results. Two alternative solutions (iterative and explicit normal mode expansion) for the non-linear fourth order partial differential equations describing the HTA transducer's plate diaphragm response in the presence of an arbitrary backplate shape are fully developed. The first explicit relations for the spatially dependent damped natural frequency and damping factor of the diaphragm are derived. A complete discussion of acoustic dissipation processes in cylindrical ducts is presented. The eigenproblem matrix formulism to predict the molecular relaxational absorption in gas mixtures is developed; physical intuition on the subject is also developed, and the linearly independent energy transfer pathways are clearly identified. Eigenproblem perturbation techniques are used for the sensitivity analysis of the relaxation parameters to the assumed energy transfer rates. A semi-empirical prediction for tube wall boundary layer wall absorption is developed. Some of the first acoustic absorption measurements at temperatures up to 1200^circK are reported. Experiments were fully computer controlled. Pulse technique, spectral analysis, and time (ensemble) averaging are used

  5. Methods and analysis of processing signals of incremental optoelectronic transducer.

    Science.gov (United States)

    Szcześniak, Adam; Szcześniak, Zbigniew

    2009-09-01

    This article is a presentation of designed methods which interpolate signals from the optoelectronic transducer. This enables a way to distinguish the motion direction of the optoelectronic transducer and also to increase its accuracy. In this article methods based on logic functions, logic functions and RC circuits, phase processing were analyzed. In methods which are based on processing logic functions of transducer's signals there is a possibility of two times and four times increase in the transducer glass scale. The presented method of generating and processing sine signals with 18 degrees of the shift enables the reception of square signals with five times higher frequency compared to the basic signals. This method is universal and it can be used to the different scale of frequency multiplication of the optoelectronic transducer. The simulations of the methods were performed by using the MATLAB-SIMULINK software.

  6. Integration of Capacitive Micromachined Ultrasound Transducers to Microfluidic Devices

    KAUST Repository

    Viržonis, Darius

    2013-10-22

    The design and manufacturing flexibility of capacitive micromachined ultrasound transducers (CMUT) makes them attractive option for integration with microfluidic devices both for sensing and fluid manipulation. CMUT concept is introduced here by presentin

  7. Dynamics Characterisation of Cymbal Transducers for Power Ultrasonics Applications

    Science.gov (United States)

    Feeney, Andrew; Bejarano, Fernando; Lucas, Margaret

    A class V cymbal flextensional transducer is composed of a piezoceramic disc sandwiched between two cymbal-shaped shell end-caps. Depending on the type of piezoceramic, there exists a maximum voltage that can be reached without depolarisation, but also, at higher voltage levels, amplitude saturation can occur. In addition, there is a restriction imposed by the mechanical strength of the bonding agent. The effects of input voltage level on the vibration response of two cymbal transducers are studied. The first cymbal transducer has a standard configuration of end-caps bonded to a piezoceramic disc, whereas the second cymbal transducer is a modified design which includes a metal ring to improve the mechanical coupling with the end-caps, to enable the transducer to operate at higher voltages, thereby generating higher displacement amplitudes. This would allow the transducer to be suitable for power ultrasonics applications. Furthermore, the input voltages to each transducer are increased incrementally to determine the linearity in the dynamic responses. Through a combination of numerical modelling and experiments, it is shown how the improved mechanical coupling in the modified cymbal transducer allows higher vibration amplitudes to be reached.

  8. Can Architectural Design alter the Physiological reaction to Psychosocial Stress ?

    DEFF Research Database (Denmark)

    Brorson Fich, Lars; Jönsson, Peter; Kirkegaard, Poul Henning

    2014-01-01

    influences these mechanisms. The question that this study attempts to start addressing is therefore whether certain design, characteristics of indoor spaces can make a difference to the physiological stress response as well. Using a virtual version of the Trier Social Stress Test, in which the space...... is computer generated and properties of the space therefore can be systematically varied, we measured saliva cortisol and heart rate variability in participants in a closed room versus a room with openings. As shown by a significant linear contrast interaction between groups and TSST conditions, participants...... in the closed room responded with more pronounced cortisol reactivity to stress induction, and continued to show higher levels throughout recovery, compared to participants in the open room. No differences were found regarding any part of the autonomic nervous system....

  9. Time stress measurement device: system design and synthesis

    Science.gov (United States)

    Harchani, Noursaied; Jimenez, Fernando; Al-Mohammed, Mohammed; Esteve, Daniel; Courvoisier, M.

    2000-04-01

    System design methodology becomes a strategic activity in the industrial competition. Obtaining substantial reduction of time to market for complex and reliable products is one of the priorities for the manufacturers. Top down design, automated generation of architecture, co-design, virtual prototyping, etc. are already identified as research topics which have to be privileged. To be efficient, each theoretical contribution must be inserted in a global procedure of project management where complementary elements such as marketing, technico-economic survey, road-mapping, internal know-how,.. must be considered. In this context, this paper will present a design methodology starting from the requirement statement until the technical realization of the product, and applied to the design of a Time Stress Measurement Device for the observation of aeronautical mechanical systems.

  10. Micromachined Integrated Transducers for Ultrasound Imaging

    DEFF Research Database (Denmark)

    la Cour, Mette Funding

    The purpose of this project is to develop capacitive micromachined ultrasonic transducers (CMUTs) for medical imaging. Medical ultrasound transducers used today are fabricated using piezoelectric materials and bulk processing. To fabricate transducers capable of delivering a higher imaging...

  11. Stress analysis for wall structure in mobile hot cell design

    Energy Technology Data Exchange (ETDEWEB)

    Bahrin, Muhammad Hannan, E-mail: hannan@nuclearmalaysia.gov.my; Rahman, Anwar Abdul, E-mail: anwar@nuclearmalaysia.gov.my; Hamzah, Mohd Arif, E-mail: arif@nuclearmalaysia.gov.my; Mamat, Mohd Rizal; Azman, Azraf; Hasan, Hasni [Prototype and Plant Development Centre, Technical Services Division, Malaysian Nuclear Agency (Malaysia)

    2016-01-22

    Malaysian Nuclear Agency is developing a Mobile Hot Cell (MHC) in order to handle and manage Spent High Activity Radioactive Sources (SHARS) such as teletherapy heads and irradiators. At present, there are only two units of MHC in the world, in South Africa and China. Malaysian Mobile Hot cell is developed by Malaysian Nuclear Agency with the assistance of IAEA expert, based on the design of South Africa and China, but with improved features. Stress analysis has been performed on the design in order to fulfil the safety requirement in operation of MHC. This paper discusses the loading analysis effect from the sand to the MHC wall structure.

  12. Transducer Field Imaging Using Acoustography

    Directory of Open Access Journals (Sweden)

    Jaswinder S. Sandhu

    2012-01-01

    Full Text Available A common current practice for transducer field mapping is to scan, point-by-point, a hydrophone element in a 2D raster at various distances from the transducer radiating surface. This approach is tedious, requiring hours of scanning time to generate full cross-sectional and/or axial field distributions. Moreover, the lateral resolution of the field distribution image is dependent on the indexing steps between data points. Acoustography is an imaging process in which an acousto-optical (AO area sensor is employed to record the intensity of an ultrasound wavefield on a two-dimensional plane. This paper reports on the application of acoustography as a simple but practical method for assessing transducer field characteristics. A case study performed on a commercial transducer is reported, where the radiated fields are imaged using acoustography and compared to the corresponding quantities that are predicted numerically.

  13. Thermal properties photonic crystal fiber transducers with ferromagnetic nanoparticles

    Science.gov (United States)

    Przybysz, N.; Marć, P.; Kisielewska, A.; Jaroszewicz, L. R.

    2015-12-01

    The main aim of the research is to design new types of fiber optic transducers based on filled photonic crystal fibers for sensor applications. In our research we propose to use as a filling material nanoparticles' ferrofluids (Fe3O4 NPs). Optical properties of such transducers are studied by measurements of spectral characteristics' changes when transducers are exposed to temperature and magnetic field changes. From synthesized ferrofluid several mixtures with different NPs' concentrations were prepared. Partially filled commercially available photonic crystal fiber LMA 10 (NKT Photonics) was used to design PCF transducers. Their thermo-optic properties were tested in a temperature chamber. Taking into account magnetic properties of synthetized NPs the patch cords based on a partially filled PM 1550 PCF were measured.

  14. Cymbal and BB underwater transducers and arrays

    Energy Technology Data Exchange (ETDEWEB)

    Newnham, R.E.; Zhang, J.; Alkoy, S.; Meyer, R.; Hughes, W.J.; Hladky-Hennion, A.C.; Cochran, J.; Markley, D. [Materials Research Laboratory, Penn State University, University Park, PA 16802 (United States)

    2002-09-01

    The cymbal is a miniaturized class V flextensional transducer that was developed for use as a shallow water sound projector and receiver. Single elements are characterized by high Q, low efficiency, and medium power output capability. Its low cost and thin profile allow the transducer to be assembled into large flexible arrays. Efforts were made to model both single elements and arrays using the ATILA code and the integral equation formulation (EQI).Millimeter size microprobe hydrophones (BBs) have been designed and fabricated from miniature piezoelectric hollow ceramic spheres for underwater applications such as mapping acoustic fields of projectors, and flow noise sensors for complex underwater structures. Green spheres are prepared from soft lead zirconate titanate powders using a coaxial nozzle slurry process. A compact hydrophone with a radially-poled sphere is investigated using inside and outside electrodes. Characterization of these hydrophones is done through measurement of hydrostatic piezoelectric charge coefficients, free field voltage sensitivities and directivity beam patterns. (orig.)

  15. An invertebrate signal transducer and activator of transcription 5 (STAT5) ortholog from the disk abalone, Haliotis discus discus: Genomic structure, early developmental expression, and immune responses to bacterial and viral stresses.

    Science.gov (United States)

    Bathige, S D N K; Umasuthan, Navaneethaiyer; Park, Hae-Chul; Lee, Jehee

    2016-03-01

    Signal transducer and activator of transcription (STAT) family members are key signaling molecules that transduce cellular responses from the cell membrane to the nucleus upon Janus kinase (JAK) activation. Although seven STAT members have been reported in mammals, very limited information on STAT genes in molluscans is available. In this study, we identified and characterized a STAT paralog that is homologous to STAT5 from the disk abalone, Haliotis discus discus, and designated as AbSTAT5. Comparison of the deduced amino acid sequence for AbSTAT5 (790 amino acids) with other counterparts revealed conserved residues important for functions and typical domain regions, including the N-terminal domain, coiled-coil domain, DNA-binding domain, linker domain, and Src homology 2 (SH2) domains as mammalian counterparts. Analysis of STAT phylogeny revealed that AbSTAT5 was clustered with the molluscan subgroup in STAT5 clade with distinct evolution. According to the genomic structure of AbSTAT5, the coding sequence was distributed into 20 exons with 19 introns. Immunologically essential transcription factor-binding sites, such as GATA-1, HNF, SP1, C/EBP, Oct-1, AP1, c-Jun, and Sox-2, were predicted at the 5'-proximal region of AbSTAT5. Expression of AbSTAT5 mRNA was detected in different stages of embryonic development and observed at considerably higher levels in the morula and late veliger stages. Tissue-specific expressional studies revealed that the highest level of AbSTAT5 transcripts was detected in hemocytes, followed by gill tissues. Temporal expressions of AbSTAT5 were analyzed upon live bacterial (Vibrio parahemolyticus and Listeria monocytogenes), viral (viral hemorrhagic septicemia virus), and pathogen-associated molecular pattern (lipopolysaccharides and Poly I:C) stimulations, and significant elevations indicated immune modulation. These results suggest that AbSTAT5 may be involved in maintaining innate immune responses from developmental to adult stages in

  16. Design, processing and characterization of mechanically alloyed galfenol & lightly rare-earth doped FeGa alloys as smart materials for actuators and transducers

    Science.gov (United States)

    Taheri, Parisa

    Smart materials find a wide range of application areas due to their varied response to external stimuli. The different areas of application can be in our day to day life, aerospace, civil engineering applications, and mechatronics to name a few. Magnetostrictive materials are a class of smart materials that can convert energy between the magnetic and elastic states. Galfenol is a magnetostrictive alloy comprised primarily of the elements iron (Fe) and gallium (Ga). Galfenol exhibits a unique combination of mechanical and magnetostrictive (magnetic) properties that legacy smart materials do not. Galfenol's ability to function while in tension, mechanical robustness and high Curie temperature (600 °C) is attracting interest for the alloy's use in mechanically harsh and elevated temperature environments. Applications actively being investigated include transducers for down-hole use, next-generation fuel injectors, sensing, and energy harvesting devices. Understanding correlations between microstructure, electronic structure, and functional response is key to developing novel magnetostrictive materials for sensor and actuator technologies. To this end, in the first part of this thesis we report successful fabrication and investigation of magnetic and magnetostrictive properties of mechanically alloyed Fe81Ga19 compounds. For the first time, we could measure magnetostrictive properties of mechanically alloyed FeGa compounds. A maximum saturation magnetostriction of 41 ppm was achieved which is comparable to those measured from polycrystalline FeGa alloys prepared by other processing techniques, namely gas atomization and cold rolling. Overall, this study demonstrates the feasibility of large-scale production of FeGa polycrystalline alloys powders by a simple and cost-effective mechanical alloying technique. In the second part of this work, we report for the first time, experimental results pertaining to successful fabrication and advanced characterization of a series

  17. Nonlinear Adaptive Parameter Estimation Techniques for Magnetic Transducers Operating in Hysteretic Regimes

    National Research Council Canada - National Science Library

    Nealis, James M; Smith, Ralph C

    2004-01-01

    Increased control demands in applications including high speed milling and hybrid motor design have led to the utilization of magnetostrictive transducers operating in hysteretic and nonlinear regimes...

  18. Piezoelectric hollow sphere transducers: The 'BBs'

    Science.gov (United States)

    Alkoy, Sedat

    This thesis describes the design, fabrication, modeling and device characteristics of ultrasound transducers developed from millimeter size piezoelectric ceramic hollow spheres. Green ceramic hollow spheres were produced using a coaxial nozzle slurry process and a sacrificial core coating process in the size range of 1-6 mm in diameter and 12-200 μm in wall thickness. Ceramic powders with the morphotropic phase boundary compositions of lead zirconate titanate solid solution known as PZT-4 and PZT-5A, and a modified lead titanate composition were used in these two processes. After sintering, the desired shapes were obtained by drilling, grinding, or polishing. Sphere surfaces were then coated with an electrode material in desired shapes and area of coverage. Two main poling configurations were studied: a radial poling configuration with inside and outside electrodes, and a tangential poling with top and bottom outside electrodes with several different electrode patterns. Dielectric, piezoelectric and ferroelectric properties of these transducers were measured. Vibration modes were determined using the ATILA™ finite element analysis (FEA) code, and associated resonance frequencies were measured and compared to the calculated values. The effect of sphere dimensions, materials and electrode configurations were analyzed using FEA. It was determined from the finite elements analysis of the structure that wall thickness variations do not have a pronounced affect on the vibrations of the structure at lower frequencies (from kHz to low MHz). Focused transducers were prepared for biomedical ultrasound imaging from dish-shape shell sections of the hollow spheres. Pulse-echo characteristics such as, insertion loss, waveform and bandwidth were measured. These transducers were also modeled using the FEA. Transducer operation frequencies of up to 50 MHz were achieved with f-numbers down to 1. Omnidirectional miniature hydrophones were prepared from radially poled hollow

  19. Characterization of Dielectric Electroactive Polymer transducers

    DEFF Research Database (Denmark)

    Nielsen, Dennis; Møller, Martin B.; Sarban, Rahimullah

    2014-01-01

    This paper analysis the small-signal model of the Dielectric Electro Active Polymer (DEAP) transducer. The DEAP transducer have been proposed as an alternative to the electrodynamic transducer in sound reproduction systems. In order to understand how the DEAP transducer works, and provide guideli...

  20. Bonding and impedance matching of acoustic transducers using silver epoxy.

    Science.gov (United States)

    Son, Kyu Tak; Lee, Chin C

    2012-04-01

    Silver epoxy was selected to bond transducer plates on glass substrates. The properties and thickness of the bonding medium affect the electrical input impedance of the transducer. Thus, the thickness of the silver epoxy bonding layer was used as a design parameter to optimize the structure for the transducer input impedance to match the 50 Ω output impedance of most radio frequency (RF) generators. Simulation and experimental results show that nearly perfect matching is achieved without using any matching circuit. At the matching condition, the transducer operates at a frequency band a little bit below the half-wavelength resonant frequency of the piezoelectric plate. In experiments, lead titanate (PT) piezoelectric plates were employed. Both full-size, 11.5 mm × 2 mm × 0.4 mm, and half-size, 5.75 mm × 2 mm × 0.4 mm, can be well matched using optimal silver epoxy thickness. The transducer assemblies demonstrate high efficiency. The conversion loss from electrical power to acoustic power in soda-lime glass is 4.3 dB. This loss is low considering the fact that the transducers operate at off-resonance by 12%. With proper choice of silver epoxy thickness, the transducer can be matched at the fundamental, the 3rd and 5th harmonic frequencies. This leads to the possible realization of triple-band transducers. Reliability was assessed with thermal cycling test according to Telcordia GR-468-Core recommendation. Of the 30 transducer assemblies tested, none broke until 2900 cycles and 27 have sustained beyond 4050 cycles. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Ultrasonic Transducer Irradiation Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Daw, Joshua [Idaho National Lab. (INL), Idaho Falls, ID (United States); Palmer, Joe [Idaho National Lab. (INL), Idaho Falls, ID (United States); Ramuhalli, Pradeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Keller, Paul [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Montgomery, Robert [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chien, Hual-Te [Argonne National Lab. (ANL), Argonne, IL (United States); Kohse, Gordon [MIT (Massachusetts Inst. of Technology), Cambridge, MA (United States); Tittmann, Bernhard [Pennsylvania State Univ., University Park, PA (United States); Reinhardt, Brian [Pennsylvania State Univ., University Park, PA (United States); Rempe, Joy [Rempe and Associates, Idaho Falls, ID (United States)

    2015-02-01

    Ultrasonic technologies offer the potential for high-accuracy and -resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other ongoing efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. For this reason, the Pennsylvania State University (PSU) was awarded an ATR NSUF project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2. The goal of this research is to characterize and demonstrate magnetostrictive and piezoelectric transducer operation during irradiation, enabling the development of novel radiation-tolerant ultrasonic sensors for use in Material Testing Reactors (MTRs). As such, this test is an instrumented lead test and real-time transducer performance data is collected along with temperature and neutron and gamma flux data. The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers. To date, one piezoelectric

  2. Natural fiber composite design and characterization for limit stress prediction in multiaxial stress state

    Directory of Open Access Journals (Sweden)

    Christopher C. Ihueze

    2015-07-01

    Full Text Available This paper focuses on the design of natural fiber composites and analysis of multiaxial stresses in relation to yield limit stresses of composites loaded off the fibers axis. ASTM D638-10 standard for tensile test was used to design and compose composites of plantain fiber reinforced polyester (PFRP. While the rule of mixtures was used in the evaluation of properties of composites in the fiber direction the evaluation of properties perpendicular or transverse to the fiber direction was done based on the value of the orthogonal stresses evaluated using ANSYS finite element software, the application of the Brintrup equation and Halpin–Tai equation. The yield strength for the plantain empty fruit bunch fiber reinforced polyester resin (PEFBFRP was estimated as 33.69 MPa while the yield strength of plantain pseudo stem fiber reinforced polyester resin (PPSFRP was estimated as 29.24 MPa. Above all, the PEFBFRP with average light absorbance peak of 45.47 was found to have better mechanical properties than the PPSFRP with average light absorbance peak of 45.77.

  3. Turbine transducer developed for adverse conditions

    International Nuclear Information System (INIS)

    Cooper, D.R.; Edson, J.L.

    1982-01-01

    This paper reviews the latest developments that the Idaho National Engineering Laboratory (INEL) has made on a turbine transducer used in measurement of two-phase flow. It is operated in a modular configuration with a drag transducer to provide mass flow data. Current configurations allow its use in single modules or in multiples to provide flow profile information. The turbine can also provide mass flow data when used with associated instrumentation such as a densitometer. The transducer, which is the product of long investigations and test series, is subject to high vibration loading and high temperatures as well as a borated liquid environment; flow conditions range from all liquid to all steam and from ambient temperatures to over 600 0 F at pressures up to 2200 psi. Graphite bearing and carbide shaft materials were selected to provide corrosion resistance along with mechanical integrity, and resistance to wear. The new turbine design has met all operational requirements in actual use and in extended lifetime tests

  4. Performance Evaluation of Pressure Transducers for Water Impacts

    Science.gov (United States)

    Vassilakos, Gregory J.; Stegall, David E.; Treadway, Sean

    2012-01-01

    The Orion Multi-Purpose Crew Vehicle is being designed for water landings. In order to benchmark the ability of engineering tools to predict water landing loads, test programs are underway for scale model and full-scale water impacts. These test programs are predicated on the reliable measurement of impact pressure histories. Tests have been performed with a variety of pressure transducers from various manufacturers. Both piezoelectric and piezoresistive devices have been tested. Effects such as thermal shock, pinching of the transducer head, and flushness of the transducer mounting have been studied. Data acquisition issues such as sampling rate and anti-aliasing filtering also have been studied. The response of pressure transducers have been compared side-by-side on an impulse test rig and on a 20-inch diameter hemisphere dropped into a pool of water. The results have identified a range of viable configurations for pressure measurement dependent on the objectives of the test program.

  5. Capacitive Micromachined Ultrasonic Transducers (CMUTs for Underwater Imaging Applications

    Directory of Open Access Journals (Sweden)

    Jinlong Song

    2015-09-01

    Full Text Available A capacitive micromachined ultrasonic transducer structure for use in underwater imaging is designed, fabricated and tested in this paper. In this structure, a silicon dioxide insulation layer is inserted between the top electrodes and the vibration membrane to prevent ohmic contact. The capacitance-voltage (C-V characteristic curve shows that the transducer offers suitable levels of hysteresis and repeatability performance. The −6 dB center frequency is 540 kHz and the transducer has a bandwidth of 840 kHz for a relative bandwidth of 155%. Underwater pressure of 143.43 Pa is achieved 1 m away from the capacitive micromachined ultrasonic transducer under 20  excitation. Two-dimensional underwater ultrasonic imaging, which is able to prove that a rectangular object is present underwater, is achieved. The results presented here indicate that our work will be highly beneficial for the establishment of an underwater ultrasonic imaging system.

  6. Tunable interdigital transducers made of piezoelectric macro-fiber composite

    Science.gov (United States)

    Mańka, Michał; Martowicz, Adam; Rosiek, Mateusz; Stepinski, Tadeusz; Uhl, Tadeusz

    2016-11-01

    The number of applications of Lamb waves (LWs) based structural health monitoring (SHM) has significantly increased in recent decades. The growth of interest results from several advantages of this diagnostic technique, that is, considerable mode selectivity and directivity that allow for the assessment of the technical condition of a monitored structure. Successful applications of LWs in the field of SHM stimulate continuous improvement of the transducers’ design to enable capturing more reliable diagnostic data. The paper introduces a new type of transducer that may be used in the LWs based SHM systems, namely tunable-interdigital transducer (T-IDT) based on macro-fiber composites (MFC). The authors provide a short overview on different types of transducers that may be used in SHM applications, followed by a detailed description of the structure of proposed T-IDT. Finally, the results of numerical and experimental tests carried out employing the proposed transducer are discussed and compared to those obtained with a traditional IDT.

  7. NORMAL PRESSURE AND FRICTION STRESS MEASUREMENT IN ROLLING PROCESSES

    DEFF Research Database (Denmark)

    Henningsen, Poul; Arentoft, Mogens; Lagergren, Jonas

    2005-01-01

    the output from the transducer, the friction stress and normal pressure in the contact zone can be determined. The new concept differs from existing pin designs by a lower disturbance of lubricant film and material flow and limited penetration of material between transducer and roll. Aluminum, cupper...... and steel strips with a width of 40 mm was rolled with reduction varying from 2.7% to 29%, in a pilot mill. For evaluating the transducer, the measured contact forces are compared with external measurements of roll separating forces and torque. The determined friction coefficients are compared with values...

  8. Multilevel inverter based class D audio amplifier for capacitive transducers

    DEFF Research Database (Denmark)

    Nielsen, Dennis; Knott, Arnold; Andersen, Michael A. E.

    2014-01-01

    The reduced semiconductor voltage stress makes the multilevel inverters especially interesting, when driving capacitive transducers for audio applications. A ± 300 V flying capacitor class D audio amplifier driving a 100 nF load in the midrange region of 0.1-3.5 kHz with Total Harmonic Distortion...

  9. Multilevel inverter based class D audio amplifier for capacitive transducers

    DEFF Research Database (Denmark)

    Nielsen, Dennis; Knott, Arnold; Andersen, Michael A. E.

    2014-01-01

    The reduced semiconductor voltage stress makes the multilevel inverters especially interesting, when driving capacitive transducers for audio applications. A ± 300 V flying capacitor class D audio amplifier driving a 100 nF load in the midrange region of 0.1-3.5 kHz with Total Harmonic Distortion...... plus Noise (THD+N) belo w1%is presented....

  10. Auto-positioning ultrasonic transducer system

    Science.gov (United States)

    Buchanan, Randy K. (Inventor)

    2010-01-01

    An ultrasonic transducer apparatus and process for determining the optimal transducer position for flow measurement along a conduit outer surface. The apparatus includes a transmitting transducer for transmitting an ultrasonic signal, said transducer affixed to a conduit outer surface; a guide rail attached to a receiving transducer for guiding movement of a receiving transducer along the conduit outer surface, wherein the receiving transducer receives an ultrasonic signal from the transmitting transducer and sends a signal to a data acquisition system; and a motor for moving the receiving transducer along the guide rail, wherein the motor is controlled by a controller. The method includes affixing a transmitting transducer to an outer surface of a conduit; moving a receiving transducer on the conduit outer surface, wherein the receiving transducer is moved along a guide rail by a motor; transmitting an ultrasonic signal from the transmitting transducer that is received by the receiving transducer; communicating the signal received by the receiving transducer to a data acquisition and control system; and repeating the moving, transmitting, and communicating along a length of the conduit.

  11. Calculations for Piezoelectric Ultrasonic Transducers

    DEFF Research Database (Denmark)

    Jensen, Henrik

    1986-01-01

    Analysis of piezoelectric ultrasonic transducers implies a solution of a boundary value problem, for a boay which consists of different materials, including a piezoelectric part. The problem is dynamic at frequencies, where a typical wavelength is somewhat less than the size of the body. Radiation...... and in particular the finite element method are considered. The finite element method is utilized for analysis of axisymmetric transducers. An explicit, fully piezoelectric, triangular ring element, with linear variations in displacememnt and electric potential is given. The influence of a fluid half-space is also...

  12. Rugged Direct-Current Transducer

    Science.gov (United States)

    Mclyman, W. T.

    1991-01-01

    Direct-current transducer withstands thermal and mechanical shocks. Operates from single, nominally 15-V power supply and nearly insensitive to both large variations in temperature and variations of as much as plus or minus 5 V in supply voltage. Its output voltage highly linear function of sensed current, with full-scale value of about 3 Vdc and offset of about 0.1 Vdc at 0 sensed current. Ruggedness of transducer due in large part to novel magnetic core, machined from solid block of nickel/iron high-permeability, low-hysteresis alloy.

  13. Home Automation System Based on Intelligent Transducer Enablers

    Science.gov (United States)

    Suárez-Albela, Manuel; Fraga-Lamas, Paula; Fernández-Caramés, Tiago M.; Dapena, Adriana; González-López, Miguel

    2016-01-01

    This paper presents a novel home automation system named HASITE (Home Automation System based on Intelligent Transducer Enablers), which has been specifically designed to identify and configure transducers easily and quickly. These features are especially useful in situations where many transducers are deployed, since their setup becomes a cumbersome task that consumes a significant amount of time and human resources. HASITE simplifies the deployment of a home automation system by using wireless networks and both self-configuration and self-registration protocols. Thanks to the application of these three elements, HASITE is able to add new transducers by just powering them up. According to the tests performed in different realistic scenarios, a transducer is ready to be used in less than 13 s. Moreover, all HASITE functionalities can be accessed through an API, which also allows for the integration of third-party systems. As an example, an Android application based on the API is presented. Remote users can use it to interact with transducers by just using a regular smartphone or a tablet. PMID:27690031

  14. Home Automation System Based on Intelligent Transducer Enablers

    Directory of Open Access Journals (Sweden)

    Manuel Suárez-Albela

    2016-09-01

    Full Text Available This paper presents a novel home automation system named HASITE (Home Automation System based on Intelligent Transducer Enablers, which has been specifically designed to identify and configure transducers easily and quickly. These features are especially useful in situations where many transducers are deployed, since their setup becomes a cumbersome task that consumes a significant amount of time and human resources. HASITE simplifies the deployment of a home automation system by using wireless networks and both self-configuration and self-registration protocols. Thanks to the application of these three elements, HASITE is able to add new transducers by just powering them up. According to the tests performed in different realistic scenarios, a transducer is ready to be used in less than 13 s. Moreover, all HASITE functionalities can be accessed through an API, which also allows for the integration of third-party systems. As an example, an Android application based on the API is presented. Remote users can use it to interact with transducers by just using a regular smartphone or a tablet.

  15. Home Automation System Based on Intelligent Transducer Enablers.

    Science.gov (United States)

    Suárez-Albela, Manuel; Fraga-Lamas, Paula; Fernández-Caramés, Tiago M; Dapena, Adriana; González-López, Miguel

    2016-09-28

    This paper presents a novel home automation system named HASITE (Home Automation System based on Intelligent Transducer Enablers), which has been specifically designed to identify and configure transducers easily and quickly. These features are especially useful in situations where many transducers are deployed, since their setup becomes a cumbersome task that consumes a significant amount of time and human resources. HASITE simplifies the deployment of a home automation system by using wireless networks and both self-configuration and self-registration protocols. Thanks to the application of these three elements, HASITE is able to add new transducers by just powering them up. According to the tests performed in different realistic scenarios, a transducer is ready to be used in less than 13 s. Moreover, all HASITE functionalities can be accessed through an API, which also allows for the integration of third-party systems. As an example, an Android application based on the API is presented. Remote users can use it to interact with transducers by just using a regular smartphone or a tablet.

  16. Irradiation Testing of Ultrasonic Transducers

    International Nuclear Information System (INIS)

    Daw, J.; Rempe, J.; Palmer, J.; Tittmann, B.; Reinhardt, B.; Kohse, G.; Ramuhalli, P.; Montgomery, R.; Chien, H.T.; Villard, J.F.

    2013-06-01

    Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of numerous parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of single, small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of existing knowledge of ultrasonic transducer material survivability under irradiation conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate promising magnetostrictive and piezoelectric transducer performance in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 10 21 n/cm 2 (E> 0.1 MeV). This test will be an instrumented lead test; and real-time transducer performance data will be collected along with temperature and neutron and gamma flux data. By characterizing magnetostrictive and piezoelectric transducer survivability during irradiation, test results will enable the development of novel radiation tolerant ultrasonic sensors for use in Material and Test Reactors (MTRs). The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers. (authors)

  17. Macro design effects on stress distribution around implants: A photoelastic stress analysis

    Directory of Open Access Journals (Sweden)

    Serhat Emre Ozkir

    2012-01-01

    Conclusion: As there were observable differences between the implant types, straight placed cylindrical implants showed better stress distribution characteristics, while inclined tapering implants had better stress distribution characteristics.

  18. Vibration characterisation of cymbal transducers for power ultrasonic applications

    Science.gov (United States)

    Bejarano, F.; Feeney, A.; Lucas, M.

    2012-08-01

    A Class V cymbal flextensional transducer is composed of a piezoceramic disc or ring sandwiched between two cymbal-shaped shell end-caps. These end-caps act as mechanical transformers to convert high impedance, low radial displacement of the piezoceramic into low impedance, large axial motion of the end-cap. The cymbal transducer was developed in the early 1990's at Penn State University, and is an improvement of the moonie transducer which has been in use since the 1980's. Despite the fact that cymbal transducers have been used in many fields, both as sensors and actuators, due to its physical limitations its use has been mainly at low power intensities. It is only very recently that its suitability for high amplitude and high power applications has been studied, and consequently implementation in this area of research remains undeveloped. This paper employs experimental modal analysis (EMA), vibration response measurements and electrical impedance measurements to characterise two variations of the cymbal transducer design, both aimed at incorporation in ultrasonic cutting devices. The transducers are fabricated using the commercial Eccobond 45LV epoxy adhesive as the bonding agent. The first cymbal transducer is of the classic design where the piezoceramic disc is bonded directly to the end-caps. The second cymbal transducer includes a metal ring bonded to the outer edge of the piezoceramic disc. The reason for the inclusion of this metal ring is to improve the mechanical coupling with the end-caps. This would therefore make this design particularly suitable for power ultrasonic applications, reducing the possibility of debonding at the higher ultrasonic amplitudes. The experimental results demonstrate that the second cymbal design is a significant improvement on the more classic design, allowing the transducer to operate at higher voltages and higher amplitudes, exhibiting a linear response over a practical power ultrasonic device driving voltage range. The

  19. Dissimilar trend of nonlinearity in ultrasound transducers and systems at resonance and non-resonance frequencies

    DEFF Research Database (Denmark)

    Ghasemi, Negareh; Zare, Firuz; Davari, Pooya

    2017-01-01

    Several factors can affect performance of an ultrasound system such as quality of excitation signal and ultrasound transducer behaviour. Nonlinearity of piezoelectric ultrasound transducers is a key determinant in designing a proper driving power supply. Although, the nonlinearity of piezoelectri...... receiver is a function of a voltage across the resistor in the RLC branches and is related to the resonance frequencies of the ultrasound transducer....

  20. Experimental evaluation of cMUT and PZT transducers in receive only mode for photoacoustic imaging

    Science.gov (United States)

    Warshavski, O.; Meynier, C.; Sénégond, N.; Chatain, P.; Felix, N.; Nguyen-Dinh, A.

    2016-03-01

    In photoacoustic imaging, the angular reception performance of ultrasonic transducers is a critical parameter to be considered for system designers. The quantitative comparison between cMUT and PZT emphasizes the difference between the transducer requirements and specifications between conventional ultrasound and photoacoustic imaging. In this present work, we show significant benefits of cMUT based array transducers over conventional PZT arrays for the improvement of quality in photoacoustic imaging systems.

  1. Class H power amplifier for power saving in fluxgate current transducers

    OpenAIRE

    Velasco Quesada, Guillermo; Román Lumbreras, Manuel; Pérez Delgado, Raul; Conesa Roca, Alfons

    2016-01-01

    This paper presents a new improvement in the design of a fluxgate-based current transducer in order to reduce the power consumption of control electronics. The proposed improvement involves the replacement of the output linear amplifier of the transducer by a class H amplifier. The output amplifier is devoted to the magnetic flux compensation and generates the transducer output current, which is proportional to the current to be measured. In this way, it is possible to reduce significantly th...

  2. A Direct Driver for Electrostatic Transducers

    DEFF Research Database (Denmark)

    Nielsen, Dennis; Knott, Arnold; Andersen, Michael A. E.

    2014-01-01

    Electrostatic transducers represent a very interesting alternative to the traditional inefficient electrodynamic transducers. In order to establish the full potential of these transducers, power amplifiers which fulfill the strict requirements imposed by such loads (high impedance, frequency...... depended, nonlinear and high bias voltage for linearization) must be developed. This paper analyzes a power stage suitable for driving an electrostatic transducer under biasing. Measurement results of a ±400 V prototype amplifier are shown. THD below 1% is reported....

  3. Underwater pipeline impact localization using piezoceramic transducers

    Science.gov (United States)

    Zhu, Junxiao; Ho, Siu Chun Michael; Patil, Devendra; Wang, Ning; Hirsch, Rachel; Song, Gangbing

    2017-10-01

    Reports indicated that impact events accounted for 47% of offshore pipeline failures, which calls for impact detection and localization for subsea pipelines. In this paper, an innovative method for rapid localization of impacts on underwater pipelines utilizing a novel determination technique for both arrival-time and group velocity (ATGV) of ultrasonic guided waves with lead zirconate titanate (PZT) transducers is described. PZT transducers mounted on the outer surface of a model pipeline were utilized to measure ultrasonic guided waves generated by impact events. Based on the signals from PZT sensors, the ATGV technique integrates wavelet decomposition, Hilbert transform and statistical analysis to pinpoint the arrival-time of the designated ultrasonic guided waves with a specific group velocity. Experimental results have verified the effectiveness and the localization accuracy for eight impact points along a model underwater pipeline. All estimations errors were small and were comparable with the wavelength of the designated ultrasonic guided waves. Furthermore, the method is robust against the low frequency structural vibration introduced by other external forces.

  4. Acoustic lens for capacitive micromachined ultrasonic transducers

    Science.gov (United States)

    Chang, Chienliu; Firouzi, Kamyar; Park, Kwan Kyu; Sarioglu, Ali Fatih; Nikoozadeh, Amin; Yoon, Hyo-Seon; Vaithilingam, Srikant; Carver, Thomas; Khuri-Yakub, Butrus T.

    2014-08-01

    Capacitive micromachined ultrasonic transducers (CMUTs) have great potential to compete with traditional piezoelectric transducers in therapeutic ultrasound applications. In this paper we have designed, fabricated and developed an acoustic lens formed on the CMUT to mechanically focus ultrasound. The acoustic lens was designed based on the paraxial theory and made of silicone rubber for acoustic impedance matching and encapsulation. The CMUT was fabricated based on the local oxidation of silicon (LOCOS) and fusion-bonding. The fabricated CMUT was verified to behave like an electromechanical resonator in air and exhibited wideband response with a center frequency of 2.2 MHz in immersion. The fabrication for the acoustic lens contained two consecutive mold castings and directly formed on the surface of the CMUT. Applied with ac burst input voltages at the center frequency, the CMUT with the acoustic lens generated an output pressure of 1.89 MPa (peak-to-peak) at the focal point with an effective focal gain of 3.43 in immersion. Compared to the same CMUT without a lens, the CMUT with the acoustic lens demonstrated the ability to successfully focus ultrasound and provided a viable solution to the miniaturization of the multi-modality forward-looking endoscopes without electrical focusing.

  5. Acoustic lens for capacitive micromachined ultrasonic transducers

    International Nuclear Information System (INIS)

    Chang, Chienliu; Firouzi, Kamyar; Sarioglu, Ali Fatih; Nikoozadeh, Amin; Yoon, Hyo-Seon; Vaithilingam, Srikant; Carver, Thomas; Khuri-Yakub, Butrus T; Kyu Park, Kwan

    2014-01-01

    Capacitive micromachined ultrasonic transducers (CMUTs) have great potential to compete with traditional piezoelectric transducers in therapeutic ultrasound applications. In this paper we have designed, fabricated and developed an acoustic lens formed on the CMUT to mechanically focus ultrasound. The acoustic lens was designed based on the paraxial theory and made of silicone rubber for acoustic impedance matching and encapsulation. The CMUT was fabricated based on the local oxidation of silicon (LOCOS) and fusion-bonding. The fabricated CMUT was verified to behave like an electromechanical resonator in air and exhibited wideband response with a center frequency of 2.2 MHz in immersion. The fabrication for the acoustic lens contained two consecutive mold castings and directly formed on the surface of the CMUT. Applied with ac burst input voltages at the center frequency, the CMUT with the acoustic lens generated an output pressure of 1.89 MPa (peak-to-peak) at the focal point with an effective focal gain of 3.43 in immersion. Compared to the same CMUT without a lens, the CMUT with the acoustic lens demonstrated the ability to successfully focus ultrasound and provided a viable solution to the miniaturization of the multi-modality forward-looking endoscopes without electrical focusing. (paper)

  6. Superconducting Qubit Optical Transducer (SQOT)

    Science.gov (United States)

    2015-08-05

    has photon loss in the optical fibre would appear has an effective T1 process and destroy any entanglement. 2.2.3 TEMPORAL MODE FILTER FUNCTION To...SECURITY CLASSIFICATION OF: The SQOT (Superconducting Qubit Optical Transducer) project proposes to build a novel electro- optic system which can...exchange quantum information between optical qubits at telecom frequencies and superconducting qubits. A direct quantum information transfer between

  7. Optical transducers with frequency output

    Science.gov (United States)

    Osadchuk, Oleksandr V.; Osadchuk, Volodymyr S.; Osadchuk, Iaroslav O.; Kolimoldayev, Maksat; Komada, Paweł; Mussabekov, Kanat

    2017-08-01

    In this work the characteristics research of microelectronic transducers of optical radiation with a frequency output signal on the basis of a hybrid integrated circuit consisting of a bipolar and a field-effect transistor with a Schottky barrier is presented. The connection of an external inductance to electrodes a collector - drain allows to implement the auto generating device. The frequency of the device generation depends on power of optical radiation falling on photosensing elements as a photoresistor, photodiode and photosensing transistors switched on in a circuit of the self-excited oscillator. The impedance on electrodes the collector - drain of bipolar and field transistors has capacitive reactive part and negative active resistance, which compensates power losses in a tuning circuit of the device. On the base of a nonlinear equivalent circuit of the transducer on an alternating current the analytical expressions of function of transformation and equation of sensitivity are obtained. The sensitivity of optical transducers lays in a range from 25 kHz/μWt/cm2 up to 150 kHz/μWt/cm2.

  8. Design of A Vibration and Stress Measurement System for an Advanced Power Reactor 1400 Reactor Vessel Internals Comprehensive Vibration Assessment Program

    International Nuclear Information System (INIS)

    Ko, Doyoung; Kim, Kyuhyung

    2013-01-01

    In accordance with the US Nuclear Regulatory Commission (US NRC), Regulatory Guide 1.20, the reactor vessel internals comprehensive vibration assessment program (RVI CVAP) has been developed for an Advanced Power Reactor 1400 (APR1400). The purpose of the RVI CVAP is to verify the structural integrity of the reactor internals to flow-induced loads prior to commercial operation. The APR1400 RVI CVAP consists of four programs (analysis, measurement, inspection, and assessment). Thoughtful preparation is essential to the measurement program, because data acquisition must be performed only once. The optimized design of a vibration and stress measurement system for the RVI CVAP is essential to verify the integrity of the APR1400 RVI. We successfully designed a vibration and stress measurement system for the APR1400 RVI CVAP based on the design materials, the hydraulic and structural analysis results, and performance tests of transducers in an extreme environment. The measurement system designed in this paper will be utilized for the APR1400 RVI CVAP as part of the first construction project in Korea

  9. DESIGN OF A VIBRATION AND STRESS MEASUREMENT SYSTEM FOR AN ADVANCED POWER REACTOR 1400 REACTOR VESSEL INTERNALS COMPREHENSIVE VIBRATION ASSESSMENT PROGRAM

    Directory of Open Access Journals (Sweden)

    DO-YOUNG KO

    2013-04-01

    Full Text Available In accordance with the US Nuclear Regulatory Commission (US NRC, Regulatory Guide 1.20, the reactor vessel internals comprehensive vibration assessment program (RVI CVAP has been developed for an Advanced Power Reactor 1400 (APR1400. The purpose of the RVI CVAP is to verify the structural integrity of the reactor internals to flow-induced loads prior to commercial operation. The APR1400 RVI CVAP consists of four programs (analysis, measurement, inspection, and assessment. Thoughtful preparation is essential to the measurement program, because data acquisition must be performed only once. The optimized design of a vibration and stress measurement system for the RVI CVAP is essential to verify the integrity of the APR1400 RVI. We successfully designed a vibration and stress measurement system for the APR1400 RVI CVAP based on the design materials, the hydraulic and structural analysis results, and performance tests of transducers in an extreme environment. The measurement system designed in this paper will be utilized for the APR1400 RVI CVAP as part of the first construction project in Korea.

  10. Transducers

    Digital Repository Service at National Institute of Oceanography (India)

    Chakraborty, B.

    stream_size 27 stream_content_type text/plain stream_name Encycl_Microcomputers_18_335.pdf.txt stream_source_info Encycl_Microcomputers_18_335.pdf.txt Content-Encoding ISO-8859-1 Content-Type text/plain; charset=ISO-8859-1 ...

  11. A novel rheometer design for yield stress fluids

    Science.gov (United States)

    Joseph R. Samaniuk; Timothy W. Shay; Thatcher W. Root; Daniel J. Klingenberg; C. Tim Scott

    2014-01-01

    An inexpensive, rapid method for measuring the rheological properties of yield stress fluids is described and tested. The method uses an auger that does not rotate during measurements, and avoids material and instrument-related difficulties, for example, wall slip and the presence of large particles, associated with yield stress fluids. The method can be used...

  12. HOLOGRAPHIC VISUALIZATION OF CYLINDRICAL PIEZOCERAMIC TRANSDUCERS VIBRATIONS

    Directory of Open Access Journals (Sweden)

    R. Vasiliauskas

    2013-01-01

    Full Text Available The piezomaterial used in cylindrical piezoceramic transducers vibrations requiring high precision displacements indicates that accuracy depends on design and technological factors. The analyzed criteria have made possible to choose the piezomaterial for optimal mechatronic system having a maximal displacement. The experimental investigation of precision vibrosystems by means of 3D holographic visualization enables one to obtain appreciably larger amount of information about the vibrating surface in comparison with traditional methods. On the basis of the developed methodology of analyzing the experimental data derived from 3D holographic visualization and by using the experimental holography stand, we have obtained results making it possible to optimize the design of operation of the piezoceramic mechatronic system or its separate elements.

  13. Modeling piezoelectric ultrasonic transducers for physiotherapy

    International Nuclear Information System (INIS)

    Iglesias, E.; Frutos, J. de; Montero de Espinosa, F.

    2015-01-01

    Applications of ultrasound are well known in medical and aesthetic skin and subcutaneous fatty tissue mobilization treatments. The basic transducer used consists of a piezoelectric disk adhered to a metal delay line in capsule shape. The capsule design is critical since the two bonded elements have vibration modes which can cause very inefficient designs and vibration distributions very irregular if they are not properly studied and utilized. This must be known to avoid distributions of heat and sound pressure that could be ineffective or harmful. In this paper, using Finite Element Method and laser interferometric vibrational analysis, it has reached a piston-type solution that allows properly implement sound pressure vibration dose. (Author)

  14. A cylindrical standing wave ultrasonic motor using bending vibration transducer.

    Science.gov (United States)

    Liu, Yingxiang; Chen, Weishan; Liu, Junkao; Shi, Shengjun

    2011-07-01

    A cylindrical standing wave ultrasonic motor using bending vibration transducer was proposed in this paper. The proposed stator contains a cylinder and a bending vibration transducer. The two combining sites between the cylinder and the transducer locate at the adjacent wave loops of bending vibration of the transducer and have a distance that equal to the half wave length of bending standing wave excited in the cylinder. Thus, the bending mode of the cylinder can be excited by the bending vibration of the transducer. Two circular cone type rotors are pressed in contact to the end rims of the teeth, and the preload between the rotors and stator is accomplished by a spring and nut system. The working principle of the proposed motor was analyzed. The motion trajectories of teeth were deduced. The stator was designed and analyzed with FEM. A prototype motor was fabricated and measured. Typical output of the prototype is no-load speed of 165rpm and maximum torque of 0.45Nm at an exciting voltage of 200V(rms). Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Energy Harvesting Using a Piezoelectric “Cymbal” Transducer in Dynamic Environment

    Science.gov (United States)

    Kim, Hyeoung Woo; Batra, Amit; Priya, Shashank; Uchino, Kenji; Markley, Douglas; Newnham, Robert E.; Hofmann, Heath F.

    2004-09-01

    In this study, we investigated the capability of harvesting the electrical energy from mechanical vibrations in a dynamic environment through a “cymbal” piezoelectric transducer. Targeted mechanical vibrations lie in the range of 50-150 Hz with force amplitude in the order of 1 kN (automobile engine vibration level). It was found that under such severe stress conditions the metal-ceramic composite transducer “cymbal” is a promising structure. The metal cap enhances the endurance of the ceramic to sustain high loads along with stress amplification. In this preliminary study, the experiments were performed at the frequency of 100 Hz on a cymbal with 29 mm diameter and 1 mm thickness under a force of 7.8 N. At this frequency and force level, 39 mW power was generated from a cymbal measured across a 400 kΩ resistor. A DC-DC converter was designed which allowed the transfer of 30 mW power to a low impedance load of 5 kΩ with a 2% duty cycle and at a switching frequency of 1 kHz.

  16. Modeling of piezoelectric Langevin transducers by using mixed transfer matrix methods

    International Nuclear Information System (INIS)

    Fu, Bo; Li, Chao; Zhang, Jianming; Huang, Zhenwei; Hemsel, Tobias

    2010-01-01

    In the modeling of piezoelectric Langevin transducers using the usual transfer matrix methods, some simplifications have been adopted. This leads to a reduction in the model quality. A mixed transfer matrix method is employed in the modeling of Langevin transducers, where the pre-stressed bolt is modeled as a separate four-pole element connected to other elements in parallel. Based on the mixed transfer matrix method, the four (six)-pole element description of the piezoelectric Langevin transducer is built up, and the total transfer matrix relation is derived. The resonance frequencies of the transducer are calculated and then measured using an impedance analyzer (HP4192). Experimental results show that the mixed transfer matrix method has better modeling quality than the usual transfer matrix method for the vibration analysis of piezoelectric Langevin transducers.

  17. Characterization of a novel Optical Micro-machined Ultrasound Transducer

    NARCIS (Netherlands)

    Leinders, S.M.

    2017-01-01

    We design and demonstrate a prototype ultrasound sensor based on a photonic micro-ring resonator integrated on a silicon membrane, and show that it can detect very low pressure ultrasound waves. The use of integrated photonics in future array transducers has several benefits: for instance it

  18. Rabbit-core based sea-level logger using semiconductor transducer

    Digital Repository Service at National Institute of Oceanography (India)

    Pereira, A.M.; Desai, R.G.P.; Desa, E.; Joseph, A.; VijayKumar, K.; Methar, A.; Shirgaonkar, A.; Damodaran, V.

    A sea level logger based on Rabbit-Core micro-controller module has been designed and tested. The transducer used with the logger is a temperature-compensated semiconductor transducer, providing absolute fluid pressure in RS-485 format. The choice...

  19. Performance limitations of piezoelectric and force feedback electrostatic transducers in different applications

    International Nuclear Information System (INIS)

    Hadjiloucas, S; Walker, G C; Bowen, J W; Karatzas, L S

    2009-01-01

    Current limitations in piezoelectric and electrostatic transducers are discussed. A force-feedback electrostatic transducer capable of operating at bandwidths up to 20 kHz is described. Advantages of the proposed design are a linearised operation which simplifies the feedback control aspects and robustness of the performance characteristics to environmental perturbations. Applications in nanotechnology, optical sciences and acoustics are discussed.

  20. Fatigue criterion for the design of rotating shafts under combined stress

    Science.gov (United States)

    Loewenthal, S. H.

    1977-01-01

    A revised approach to the design of transmission shafting which considers the flexure fatigue characteristics of the shaft material under combined cyclic bending and static torsion stress is presented. A fatigue failure relation, corroborated by published combined stress test data, is presented which shows an elliptical variation of reversed bending endurance strength with static torsional stress. From this elliptical failure relations, a design formula for computing the diameter of rotating solid shafts under the most common condition of loading is developed.

  1. Class D audio amplifiers for high voltage capacitive transducers

    DEFF Research Database (Denmark)

    Nielsen, Dennis

    Audio reproduction systems contains two key components, the amplifier and the loudspeaker. In the last 20 – 30 years the technology of audio amplifiers have performed a fundamental shift of paradigm. Class D audio amplifiers have replaced the linear amplifiers, suffering from the well-known issues...... of high volume, weight, and cost. High efficient class D amplifiers are now widely available offering power densities, that their linear counterparts can not match. Unlike the technology of audio amplifiers, the loudspeaker is still based on the traditional electrodynamic transducer invented by C.W. Rice...... and E.W. Kellog in 1925 [1]. The poor efficiency of the electrodynamic transducer remains a key issue, and a significant limit of the efficiency of the complete audio reproduction systems. Also the geometric limits of the electrodynamic transducer imposes significant limits on the design of loudspeakers...

  2. Magnetometer with a miniature transducer and automatic scanning

    Science.gov (United States)

    Debnam, W. J. J.; Fales, C. L., Jr.; Breckenridge, R. A.; Pohm, A. V. (Inventor)

    1978-01-01

    The magnetometer is based on the time variation of the magnetic permeability in the magnetic material of its transducer; however, its operation is substantially different from the ordinary flux-gate magnetometer. The transducer uses 0.05 mm diameter plated magnetic wire and is made flat enabling it to make measurements of transverse magnetic fields as close as 0.08 mm from the surface, and it has very good spatial resolution because of its small active region of approximately 0.64 mm by 0.76 mm. The magnetometer uses an inexpensive clip-on millimeter for driving and processing the electrical signals and readout. It also utilizes an automatic scanning technique which is made possible by a specially designed transducer holding mechanism that replaces the ink pen on an X-Y recorder.

  3. Measurement component technology. Volume 1: Cryogenic pressure measurement technology, high pressure flange seals, hydrogen embrittlement of pressure transducer material, close coupled versus remote transducer installation and temperature compensation of pressure transducers

    Science.gov (United States)

    Hayakawa, K. K.; Udell, D. R.; Iwata, M. M.; Lytle, C. F.; Chrisco, R. M.; Greenough, C. S.; Walling, J. A.

    1972-01-01

    The results are presented of an investigation into the availability and performance capability of measurement components in the area of cryogenic temperature, pressure, flow and liquid detection components and high temperature strain gages. In addition, technical subjects allied to the components were researched and discussed. These selected areas of investigation were: (1) high pressure flange seals, (2) hydrogen embrittlement of pressure transducer diaphragms, (3) The effects of close-coupled versus remote transducer installation on pressure measurement, (4) temperature transducer configuration effects on measurements, and (5) techniques in temperature compensation of strain gage pressure transducers. The purpose of the program was to investigate the latest design and application techniques in measurement component technology and to document this information along with recommendations for upgrading measurement component designs for future S-2 derivative applications. Recommendations are provided for upgrading existing state-of-the-art in component design, where required, to satisfy performance requirements of S-2 derivative vehicles.

  4. Electrical Pressure Transducers Based on Graphene Oxide Polysiloxane Composites

    Directory of Open Access Journals (Sweden)

    Antonio PELUSO

    2010-12-01

    Full Text Available Exfoliated graphite oxide embedded into a polysiloxane matrix can be simply obtained by sonochemical approach. These nanocomposites show an electrical conductivity depending on the applied stress and have most of crucial characteristics of an electrical pressure transducer (absence of electrical hysteresis, prompt resistivity variation, etc.. The highest sensitivity for these electrical devices is obtained with exfoliated graphene oxide concentration just a little inferior to the percolation threshold (that is, 5.5wt.% of graphene.

  5. Contact Stress Design Parameters for Titanium Bearings, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In response to NASA 2015 SBIR Topic H4.02, Air-Lock proposes to define the maximum allowable contact stress for Titanium bearings. The modulus of Titanium is lower...

  6. LAVA Pressure Transducer Trade Study

    Science.gov (United States)

    Oltman, Samuel B.

    2016-01-01

    The Regolith and Environment Science and Oxygen and Lunar Volatile Extraction (RESOLVE) payload will transport the (LAVA) subsystem to hydrogen-rich locations on the moon supporting NASA's in-situ resource utilization (ISRU) programs. There, the LAVA subsystem will analyze volatiles that evolve from heated regolith samples in order to quantify how much water is present. To do this, the system needs resilient pressure transducers (PTs) to calculate the moles in the gas samples. The PT trade study includes a comparison of newly-procured models to a baseline unit with prior flight history in order to determine the PT model with the best survivability in flight-forward conditions.

  7. Thermoelastic Femoral Stress Imaging for Experimental Evaluation of Hip Prosthesis Design

    Science.gov (United States)

    Hyodo, Koji; Inomoto, Masayoshi; Ma, Wenxiao; Miyakawa, Syunpei; Tateishi, Tetsuya

    An experimental system using the thermoelastic stress analysis method and a synthetic femur was utilized to perform reliable and convenient mechanical biocompatibility evaluation of hip prosthesis design. Unlike the conventional technique, the unique advantage of the thermoelastic stress analysis method is its ability to image whole-surface stress (Δ(σ1+σ2)) distribution in specimens. The mechanical properties of synthetic femurs agreed well with those of cadaveric femurs with little variability between specimens. We applied this experimental system for stress distribution visualization of the intact femur, and the femurs implanted with an artificial joint. The surface stress distribution of the femurs sensitively reflected the prosthesis design and the contact condition between the stem and the bone. By analyzing the relationship between the stress distribution and the clinical results of the artificial joint, this technique can be used in mechanical biocompatibility evaluation and pre-clinical performance prediction of new artificial joint design.

  8. A process chain for integrating piezoelectric transducers into aluminum die castings to generate smart lightweight structures

    Directory of Open Access Journals (Sweden)

    Stefan Stein

    Full Text Available The application of piezoelectric transducers to structural body parts of machines or vehicles enables the combination of passive mechanical components with sensor and actuator functions in one single structure. According to Herold et al. [1] and Staeves [2] this approach indicates significant potential regarding smart lightweight construction. To obtain the highest yield, the piezoelectric transducers need to be integrated into the flux of forces (load path of load bearing structures. Application in a downstream process reduces yield and process efficiency during manufacturing and operation, due to the necessity of a subsequent process step of sensor/actuator application. The die casting process offers the possibility for integration of piezoelectric transducers into metal structures. Aluminum castings are particularly favorable due to their high quality and feasibility for high unit production at low cost (Brunhuber [3], Nogowizin [4]. Such molded aluminum parts with integrated piezoelectric transducers enable functions like active vibration damping, structural health monitoring or energy harvesting resulting in significant possibilities of weight reduction, which is an increasingly important driving force of automotive and aerospace industry (Klein [5], Siebenpfeiffer [6] due to increasingly stringent environmental protection laws. In the scope of those developments, this paper focuses on the entire process chain enabling the generation of lightweight metal structures with sensor and actuator function, starting from the manufacturing of piezoelectric modules over electrical and mechanical bonding to the integration of such modules into aluminum (Al matrices by die casting. To achieve this challenging goal, piezoceramic sensors/actuator modules, so-called LTCC/PZT modules (LPM were developed, since ceramic based piezoelectric modules are more likely to withstand the thermal stress of about 700 °C introduced by the casting process (Flössel et

  9. Artificial Warming of Arctic Meadow under Pollution Stress: Experimental design

    Science.gov (United States)

    Moni, Christophe; Silvennoinen, Hanna; Fjelldal, Erling; Brenden, Marius; Kimball, Bruce; Rasse, Daniel

    2014-05-01

    Boreal and arctic terrestrial ecosystems are central to the climate change debate, notably because future warming is expected to be disproportionate as compared to world averages. Likewise, greenhouse gas (GHG) release from terrestrial ecosystems exposed to climate warming is expected to be the largest in the arctic. Artic agriculture, in the form of cultivated grasslands, is a unique and economically relevant feature of Northern Norway (e.g. Finnmark Province). In Eastern Finnmark, these agro-ecosystems are under the additional stressor of heavy metal and sulfur pollution generated by metal smelters of NW Russia. Warming and its interaction with heavy metal dynamics will influence meadow productivity, species composition and GHG emissions, as mediated by responses of soil microbial communities. Adaptation and mitigation measurements will be needed. Biochar application, which immobilizes heavy metal, is a promising adaptation method to promote positive growth response in arctic meadows exposed to a warming climate. In the MeadoWarm project we conduct an ecosystem warming experiment combined to biochar adaptation treatments in the heavy-metal polluted meadows of Eastern Finnmark. In summary, the general objective of this study is twofold: 1) to determine the response of arctic agricultural ecosystems under environmental stress to increased temperatures, both in terms of plant growth, soil organisms and GHG emissions, and 2) to determine if biochar application can serve as a positive adaptation (plant growth) and mitigation (GHG emission) strategy for these ecosystems under warming conditions. Here, we present the experimental site and the designed open-field warming facility. The selected site is an arctic meadow located at the Svanhovd Research station less than 10km west from the Russian mining city of Nikel. A splitplot design with 5 replicates for each treatment is used to test the effect of biochar amendment and a 3oC warming on the Arctic meadow. Ten circular

  10. Performance of Honeywell silicon pressure transducers

    Digital Repository Service at National Institute of Oceanography (India)

    VijayKumar, K.; Joseph, A.; Desai, R.G.P.; Nagvekar, S.; Prabhudesai, S.; Damodaran, V.

    to elucidate the performance characteristics of the pressure transducer such as zero-point offset, standard deviation, hysteresis effect, linearity, accuracy, temperature-sensitivity, repeatability, and so forth. 3.1 Calibration Device In the present work... pressure transducers 184 the pressure-calibrator, whose output was considered as the true value of pressure. Amongst the currently available pressure standards, those that provide the finest pressure resolution are these quartz pressure transducers [3...

  11. Optimizing the shape of ultrasound transducers for interstitial thermal ablation

    International Nuclear Information System (INIS)

    Lafon, Cyril; Melo de Lima, David; Theillere, Yves; Prat, Frederic; Chapelon, Jean-Yves; Cathignol, Dominique

    2002-01-01

    Heat deposition by interstitial routes, especially with ultrasound-based instruments, is becoming a valuable therapeutic option for the treatments of sites, which are difficult to access from outside of the body. The active part of most interstitial ultrasound applicators described in the literature is logically tubular to induce cylindrical volumes of coagulation necrosis. Because the pressure generated by such tubular transducers falls off rapidly with radial distance, we previously proposed using a rotating plane transducer. For a plane wave, the pressure fall-off is only due to attenuation, which makes deeper lesions and shorter treatment times possible. This work represents an advance in the development of ultrasound applicators designed for interstitial applications. This new applicator used a rotating slightly focused transducer. A brief theoretical analysis resulted in the choice of a long focal distance of 22 mm to obtain a nearly constant pressure all along the therapeutic depth. To experimentally validate this focal distance, pressure measurements were made in a tissue mimicking liquid phantom and the results were compared with those obtained with a plane transducer. In vitro experiments showed that necrosis could be induced at a depth of 15 mm. In the same conditions, the greatest depth attained with a plane transducer was only 10 mm. Because each individual lesion is narrower, more lesions and more time are required to necrose a cylindrical volume. The main advantage of this new type of applicator is that it can be used to induce necrosis at a greater depth without varying either the frequency, the intensity or the transducer cooling efficiency

  12. Research and development of capacitive transducer with linear acceleration

    Science.gov (United States)

    Korobova, Natalia; Kochurina, Elena; Timoshenkov, Sergey; Chaplygin, Yuriy; Anchutin, Stepan; Kosolapov, Andrey

    2015-05-01

    Paper presents the study results and modeling of functional characteristics of the linear acceleration transducers, enabling sensors creation with the specified parameters. Sensing element made for linear acceleration transducer with torsion cruciform section has been proposed on the based design and technological principles. It allows minimizing the impact of cross-acceleration and gives the maximum of center mass displacement for high sensors sensitivity in the given dimensions. The range of measured acceleration from ± 0.2g to ± 50g was provided by changing the torsion bar thickness n = 34 ÷ 56 microns. The transducers frequency range of linear acceleration 100-150 Hz depends on the gas pressure P = 700-800Pa in which the sensor element was located. Methods converting displacement of sensing element in the sensor output have been provided. On their basis the linear acceleration transducers with analog output signal having a predetermined frequency range and high linearity of the transformation (nonlinearity 0.2-1.5%) was developed. Also the linear acceleration transducers with digital signal consuming little (no more than 850 μA), low noisy (standard deviation to 0.1mg/rt-Hz) and high sensitivity (up to 0.1mg) to the accelerations was made. Errors in manufacturing process of sensitive elements and operating environment temperature affect the changes in the characteristics of the linear acceleration transducers. It has been established that different plate thickness up to 3.6% leads to the scale factor error to 4.7%. Irreproducibility of depth anisotropic etching of silicon up to 6.6% introduces an error in the output signal of 2.9 ... 13.8mg.

  13. The assessment and measurement of adult life stress: Basic premises, operational principles, and design requirements.

    Science.gov (United States)

    Harkness, Kate L; Monroe, Scott M

    2016-07-01

    Life stress is a central factor in the onset and course of a wide range of medical and psychiatric conditions. Determining the precise etiological and pathological consequences of stress, though, has been hindered by weaknesses in prevailing definitional and measurement practices. The purpose of the current paper is to evaluate the primary strategies for defining and measuring major and minor acute life events, chronic stressors, and daily hassles as informed by 3 basic scientific premises. The first premise concerns the manner in which stress is conceptualized and operationally defined, and specifically we assert that stress measures must not conflate the stress exposure with the stress response. The second premise concerns how stress exposures are measured, and we provide guidelines for optimizing standardized and sensitive indicators of life stress. The third premise addresses the consequences of variations in the procedures for life event measurement with regard to the validity of the research designs employed. We show that life stress measures are susceptible to several sources of bias, and if these potential sources of bias are not controlled in the design of the research, spurious findings may result. Our goal is to provide a useful guide for researchers who consider life stress to be an important factor in their theoretical models of disease, wish to incorporate measures of life stress in their research, and seek to avoid the common pitfalls of past measurement practices. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  14. design of ceramic membrane supports: permeability, tensile strength and stress

    NARCIS (Netherlands)

    Biesheuvel, Pieter Maarten; Biesheuvel, P.M.; Verweij, H.

    1999-01-01

    A membrane support provides mechanical strength to a membrane top layer to withstand the stress induced by the pressure difference applied over the entire membrane and must simultaneously have a low resistance to the filtrate flow. In this paper an experimental and a theoretical approach toward the

  15. Ultrasound pressure distributions generated by high frequency transducers in large reactors.

    Science.gov (United States)

    Leong, Thomas; Coventry, Michael; Swiergon, Piotr; Knoerzer, Kai; Juliano, Pablo

    2015-11-01

    The performance of an ultrasound reactor chamber relies on the sound pressure level achieved throughout the system. The active volume of a high frequency ultrasound chamber can be determined by the sound pressure penetration and distribution provided by the transducers. This work evaluated the sound pressure levels and uniformity achieved in water by selected commercial scale high frequency plate transducers without and with reflector plates. Sound pressure produced by ultrasonic plate transducers vertically operating at frequencies of 400 kHz (120 W) and 2 MHz (128 W) was characterized with hydrophones in a 2 m long chamber and their effective operating distance across the chamber's vertical cross section was determined. The 2 MHz transducer produced the highest pressure amplitude near the transducer surface, with a sharp decline of approximately 40% of the sound pressure occurring in the range between 55 and 155 mm from the transducer. The placement of a reflector plate 500 mm from the surface of the transducer was shown to improve the sound pressure uniformity of 2 MHz ultrasound. Ultrasound at 400 kHz was found to penetrate the fluid up to 2 m without significant losses. Furthermore, 400 kHz ultrasound generated a more uniform sound pressure distribution regardless of the presence or absence of a reflector plate. The choice of the transducer distance to the opposite reactor wall therefore depends on the transducer plate frequency selected. Based on pressure measurements in water, large scale 400 kHz reactor designs can consider larger transducer distance to opposite wall and larger active cross-section, and therefore can reach higher volumes than when using 2 MHz transducer plates. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  16. Evaluation of stress distribution characteristics on various bar designs of three-implant-supported mandibular overdentures

    Directory of Open Access Journals (Sweden)

    Emre Tokar

    2017-01-01

    Full Text Available Objective: Implant-supported-overdentures, instead of conventional complete dentures, are frequently recommended to rehabilitate patients having edentulous mandible. The aim of this study was to evaluate the stress distribution characteristics of mandibular implant-supported overdentures with four different bar attachment designs. Materials and Method: A photoelastic mandibular model with three implants (3.75 mm - 13 mm placed at the interforaminal region was generated from a cast of an edentulous mandible. Four mandibular bar overdenture designs were fabricated: bar-clip, bar-galvano, bar-locator, and bar-ceka. Axial vertical loads (135 N were applied to the central fossa of the right first molar area for each overdenture design. Stress concentrations were recorded photographically and analyzed visually. Results: The tested bar attachment designs revealed low and moderate stress levels. The lowest stress was observed with the bar-clip design, followed by bar-locator, bar-ceka, and bar-galvano designs. Conclusion: The loads were distributed to all of the implants. Studied designs experienced moderate stress levels around the loaded side implant. Bars with distally placed stud attachments and surface treatment with electroforming seems to increase stress levels around the implants.

  17. Modeling of Piezoelectric Energy Harvesting Using Cymbal Transducers

    Science.gov (United States)

    Kim, Hyeoungwoo; Priya, Shashank; Uchino, Kenji

    2006-07-01

    This study reports the experimental and analytical results on a piezoelectric cymbal with 29 mm diameter and 1 mm thickness operating under force of 70 N in the frequency range of 10-200 Hz. It was found that the generated power increases with the frequency and around 100 mW can be harvested at frequency of 200 Hz across a 200 kΩ resistor. Power generation from the cymbal transducer was modeled by using the theory developed for the Belleville spring. The calculated results were found to be in good agreement with the experimental results. The results indicate that the metal-ceramic composite transducer “CYMBAL” is the most promising structure for harvesting the electric energy from automobile engine vibrations. The metal cap enhances the endurance of the ceramic to sustain high loads along with stress amplification.

  18. Numerical calculations of ultrasonic fields. 1: Transducer near fields

    Science.gov (United States)

    Johnson, J. A.

    1982-04-01

    A computer code for the calculation of linear acoustic wave propagation in homogeneous fluid and solid materials has been derived from the thermal hydraulics code STEALTH. The code uses finite difference techniques in a two dimensional mesh made up of arbitrarily shaped quadrilaterals. Problems with two dimensional plane strain or two dimensional axial symmetries can be solved. Free, fixed or stressed boundaries can be used. Transducers can be modeled by time dependent boundary conditions or by moving pistons. A brief description of the method is given and the results of the calculation of the near fields of circular flat and focused transducers are shown. These results agree with analytic theory along the axis of symmetry and with other codes that use a Huygens' reconstruction technique off axis.

  19. Toward using tire-road contact stresses in pavement design and analysis

    CSIR Research Space (South Africa)

    De Beer, Morris

    2012-10-01

    Full Text Available Optimization of road pavement design, especially towards the surface of the pavement, requires a more rational approach to modeling of truck tire-road contact stresses. Various road surfacing failures are given in this paper as examples...

  20. Towards using tire-road contact stresses in pavement design and analysis

    CSIR Research Space (South Africa)

    De Beer, Morris

    2011-09-01

    Full Text Available Optimization of road pavement design, especially towards the surface of the pavement, requires a more rational approach to modeling of truck tire-road contact stresses. Various road surfacing failures are given in this paper as examples...

  1. Opto-acoustic transducer for medical applications

    Science.gov (United States)

    Benett, W.; Celliers, P.; Da Silva, L.; Glinsky, M.; London, R.; Maitland, D.; Matthews, D.; Krulevich, P.; Lee, A.

    1999-08-31

    This invention is an optically activated transducer for generating acoustic vibrations in a biological medium. The transducer is located at the end of a fiber optic which may be located within a catheter. Energy for operating the transducer is provided optically by laser light transmitted through the fiber optic to the transducer. Pulsed laser light is absorbed in the working fluid of the transducer to generate a thermal pressure and consequent adiabatic expansion of the transducer head such that it does work against the ambient medium. The transducer returns to its original state by a process of thermal cooling. The motion of the transducer within the ambient medium couples acoustic energy into the medium. By pulsing the laser at a high repetition rate (which may vary from CW to 100 kHz) an ultrasonic radiation field can be established locally in the medium. This method of producing ultrasonic vibrations can be used in vivo for the treatment of stroke-related conditions in humans, particularly for dissolving thrombus. The catheter may also incorporate anti-thrombolytic drug treatments as an adjunct therapy and it may be operated in conjunction with ultrasonic detection equipment for imaging and feedback control. 7 figs.

  2. Stress analysis of high-level waste canisters: methods, applications, and design data

    International Nuclear Information System (INIS)

    Simonen, F.A.; Slate, S.C.

    1979-10-01

    An overview of stress analysis methods, structural design procedures, and design data is presented for canisters used to package solidified wastes, particularly borosilicate glass. In addition, waste processing, canister materials, fabrication and inspection methods, and performance testing are summarized. Sources of stress in canisters are lifting and handling loads, internal pressure, high-temperature filling operations, transient heating and cooling, differential thermal expansions of canisters and glass, and impact loadings from low-probability accidents. Results of case studies that illustrate applicable methods of stress analyses are presented for these sources of stress. Existing sections of ASME Boiler and Pressure Vessel Code are applicable to canister fabrication, but the code does not cover many aspects of canister service loadings. Specialized criteria for minimum wall thicknesses to sustain filling stresses are proposed in this report. Results of a test program to measure the creep strength of candidate canister materials are described. Methods to predict residual stresses in the walls of waste canisters are described; predicted residual stress levels agree with measured stress levels. The consequences of these residual stresses are reviewed, and stress-corrosion cracking is identified as the mode of canister failure affected by residual stresses. Canister-closure design is covered in detail, particularly the welding and inspection of the final closure seal-weld. It is shown that the methods of fracture mechanics and fatigue-crack-growth analyses are valuable tools for evaluating the performance of closure welds in the presence of crack-like defects. Canister performance in process trials at PNL shows the ability of canisters to survive high temperatures and loadings during processing. Impact tests show that a suitably designed canister can sustain severe impacts without loss of intergrity

  3. Capacitive Micromachined Ultrasonic Transducers for Therapeutic Ultrasound Applications

    Science.gov (United States)

    Wong, Serena H.; Kupnik, Mario; Watkins, Ronald D.; Butts-Pauly, Kim; Khuri-Yakub, Butrus T.

    2014-01-01

    Therapeutic ultrasound guided by magnetic resonance imaging (MRI) is a noninvasive treatment that potentially reduces mortality, lowers medical costs, and widens accessibility of treatments for patients. Recent developments in the design and fabrication of capacitive micromachined ultrasonic transducers (CMUTs) have made them competitive with piezoelectric transducers for use in therapeutic ultrasound applications. In this paper, we present the first designs and prototypes of an 8-element, concentric-ring, CMUT array to treat upper abdominal cancers. This array was simulated and designed to focus 30–50 mm into tissue and ablate a 2–3 cm diameter tumor within 1 hour. Assuming a surface acoustic output pressure of 1 MPa peak to peak (8.5 W/cm2) at 2.5 MHz, we simulated an array that produced a focal intensity of 680 W/cm2 when focusing to 35 mm. CMUT cells were then designed to meet these frequency and surface acoustic intensity specifications. These cell designs were fabricated as 2.5 mm by 2.5 mm test transducers and used to verify our models. The test transducers were shown to operate at 2.5 MHz with an output pressure of 1.4 MPa peak to peak (16.3 W/cm2). With this CMUT cell design, we fabricated a full 8-element array. Due to yield issues, we only developed electronics to focus the four center elements of the array. The beam profile of the measured array deviated from the simulated because of crosstalk effects; the beamwidth matched within 10% and sidelobes increased by 2 times, which caused the measured gain to be 16.6 compared to 27.4. PMID:19628448

  4. A Novel Rotary Piezoelectric Motor Using First Bending Hybrid Transducers

    Directory of Open Access Journals (Sweden)

    Yingxiang Liu

    2015-08-01

    Full Text Available We report a novel rotary piezoelectric motor using bending transducers in this work. Three transducers are used to drive a disk-shaped rotor together by the elliptical movements of their driving tips; these motions are produced by the hybrid of two first bending vibration modes. The proposed piezoelectric transducer has a simple structure as it only contains an aluminum alloy beam and four pieces of PZT plates. Symmetrical structure is the only necessary condition in the design process as it will ensure the resonance frequencies of the two orthogonal first bending modes are equal. Transducers with first bending resonance frequency of about 53 kHz were fabricated and assembled into a rotary motor. The proposed motor exhibits good performance on speed and torque control. Under a working frequency of 53.2 kHz, the maximum no-load speed and the maximum torque of the prototype are tested to be 53.3 rpm and of 27 mN·m.

  5. Study on the sandwich piezoelectric ceramic ultrasonic transducer in thickness vibration

    International Nuclear Information System (INIS)

    Lin Shuyu; Tian Hua

    2008-01-01

    A sandwich piezoelectric ceramic ultrasonic transducer in thickness vibration is studied. The transducer consists of front and back metal masses, and coaxially segmented, thickness polarized piezoelectric ceramic thin rings. For this kind of sandwich piezoelectric transducers in thickness vibration, it is required that the lateral dimension of the transducer is sufficiently large compared with its longitudinal dimension so that no lateral displacements in the transducer can occur (laterally clamped). In this paper, the thickness vibration of the piezoelectric ceramic stack consisting of a number of identical piezoelectric ceramic thin rings is analysed and its electro-mechanical equivalent circuit is obtained. The resonance frequency equation for the sandwich piezoelectric ceramic ultrasonic transducer in thickness vibration is derived. Based on the frequency equation, two sandwich piezoelectric ceramic ultrasonic transducers are designed and manufactured, and their resonance frequencies are measured. It is shown that the measured resonance frequencies are in good agreement with the theoretical results. This kind of sandwich piezoelectric ultrasonic transducer is expected to be used in megasonic ultrasonic cleaning and sonochemistry where high power and high frequency ultrasound is needed

  6. Focusing Modeling of OPFC Linear Array Transducer by Using Distributed Point Source Method

    Directory of Open Access Journals (Sweden)

    Ziping Wang

    2014-01-01

    Full Text Available The improvement of ultrasonic phased array detection technology is a major concern of engineering community. Orthotropic piezoelectric fiber composite (OPFC can be constructed to multielement linear array which may be applied conveniently to actuators and sensors. The phased array transducers can generate special directional strong actuator power and high sensitivity for its orthotropic performance. Focusing beam of the linear phased array transducer is obtained simply only by adjusting a parabolic time delay. In this work, the distributed point source method (DPSM is used to model the ultrasonic field. DPSM is a newly developed mesh-free numerical technique that has been developed for solving a variety of engineering problems. This work gives the basic theory of this method and solves the problems from the application of new OPFC phased array transducer. Compared with traditional transducer, the interaction effect of two OPFC linear phased array transducers is also modeled in the same medium, which shows that the pressure beam produced by the new transducer is narrower or more collimated than that produced by the conventional transducer at different angles. DPSM can be used to analyze and optimally design the OPFC linear phased array transducer.

  7. Using Portable Transducers to Measure Tremor Severity

    Directory of Open Access Journals (Sweden)

    Rodger Elble

    2016-05-01

    Full Text Available Background: Portable motion transducers, suitable for measuring tremor, are now available at a reasonable cost. The use of these transducers requires knowledge of their limitations and data analysis. The purpose of this review is to provide a practical overview and example software for using portable motion transducers in the quantification of tremor. Methods: Medline was searched via PubMed.gov in December 2015 using the Boolean expression “tremor AND (accelerometer OR accelerometry OR gyroscope OR inertial measurement unit OR digitizing tablet OR transducer.” Abstracts of 419 papers dating back to 1964 were reviewed for relevant portable transducers and methods of tremor analysis, and 105 papers written in English were reviewed in detail. Results: Accelerometers, gyroscopes, and digitizing tablets are used most commonly, but few are sold for the purpose of measuring tremor. Consequently, most software for tremor analysis is developed by the user. Wearable transducers are capable of recording tremor continuously, in the absence of a clinician. Tremor amplitude, frequency, and occurrence (percentage of time with tremor can be computed. Tremor amplitude and occurrence correlate strongly with clinical ratings of tremor severity. Discussion: Transducers provide measurements of tremor amplitude that are objective, precise, and valid, but the precision and accuracy of transducers are mitigated by natural variability in tremor amplitude. This variability is so great that the minimum detectable change in amplitude, exceeding random variability, is comparable for scales and transducers. Research is needed to determine the feasibility of detecting smaller change using averaged data from continuous long-term recordings with wearable transducers.

  8. Evaluating stress distribution in two different designs of class I partial removable dentures

    Directory of Open Access Journals (Sweden)

    F. Geramipanah

    1998-05-01

    Full Text Available In Present study a digital model of hemimaxillectomy was reconstructed by computer and stress distribution of removable partial dentures in tissues, periodontal ligament and bone were thoroughly evaluated. The maximum stress of two different removable partial denture designs which contained buccal and lingual c-shaped clasps respectively were analyzed and compared. It was assumed that a 90 gram force which is equal to an average obturator’s weight is applied outwardly. The results showed that the maximum stress distribution in these two designs is not significantly different.

  9. Optimal design of constant-stress accelerated degradation tests using the M-optimality criterion

    International Nuclear Information System (INIS)

    Wang, Han; Zhao, Yu; Ma, Xiaobing; Wang, Hongyu

    2017-01-01

    In this paper, we propose the M-optimality criterion for designing constant-stress accelerated degradation tests (ADTs). The newly proposed criterion concentrates on the degradation mechanism equivalence rather than evaluation precision or prediction accuracy which is usually considered in traditional optimization criteria. Subject to the constraints of total sample number, test termination time as well as the stress region, an optimum constant-stress ADT plan is derived by determining the combination of stress levels and the number of samples allocated to each stress level, when the degradation path comes from inverse Gaussian (IG) process model with covariates and random effects. A numerical example is presented to verify the robustness of our proposed optimum plan and compare its efficiency with other test plans. Results show that, with a slightly relaxed requirement of evaluation precision and prediction accuracy, our proposed optimum plan reduces the dispersion of the estimated acceleration factor between the usage stress level and a higher accelerated stress level, which makes an important contribution to reliability demonstration and assessment tests. - Highlights: • We establish the necessary conditions for degradation mechanism equivalence of ADTs. • We propose the M-optimality criterion for designing constant-stress ADT plans. • The M-optimality plan reduces the dispersion of the estimated accelerated factors. • An electrical connector with its stress relaxation data is used for illustration.

  10. Influence of Residual Stress on Fatigue Design of AISI 304 Stainless Steel

    Directory of Open Access Journals (Sweden)

    L. Singh

    2011-06-01

    Full Text Available Austenitic stainless steel cannot be hardened by any form of heat treatment, in fact, quenching from 10000C merely softens them. They are usually cold worked to increase the hardness. Shot peening is a cold working process that changes micro-structure as well as residual stress in the surface layer. In the present work, the compressive residual stress and fatigue strength of AISI 304 austenitic stainless steel have been evaluated at various shot peening conditions. The improvement in various mechanical properties such as hardness, damping factors and fatigue strength was noticed. Compressive residual stress induced by shot peening varies with cyclic loading due to relaxation of compressive residual stress field. The consideration of relaxed compressive residual stress field instead of original compressive residual stress field provides reliable fatigue design of components. In this paper, the exact reductions in weight and control of mechanical properties due to shot peening process are discussed.

  11. Calculation of acoustic field based on laser-measured vibration velocities on ultrasonic transducer surface

    Science.gov (United States)

    Hu, Liang; Zhao, Nannan; Gao, Zhijian; Mao, Kai; Chen, Wenyu; Fu, Xin

    2018-05-01

    Determination of the distribution of a generated acoustic field is valuable for studying ultrasonic transducers, including providing the guidance for transducer design and the basis for analyzing their performance, etc. A method calculating the acoustic field based on laser-measured vibration velocities on the ultrasonic transducer surface is proposed in this paper. Without knowing the inner structure of the transducer, the acoustic field outside it can be calculated by solving the governing partial differential equation (PDE) of the field based on the specified boundary conditions (BCs). In our study, the BC on the transducer surface, i.e. the distribution of the vibration velocity on the surface, is accurately determined by laser scanning measurement of discrete points and follows a data fitting computation. In addition, to ensure the calculation accuracy for the whole field even in an inhomogeneous medium, a finite element method is used to solve the governing PDE based on the mixed BCs, including the discretely measured velocity data and other specified BCs. The method is firstly validated on numerical piezoelectric transducer models. The acoustic pressure distributions generated by a transducer operating in an homogeneous and inhomogeneous medium, respectively, are both calculated by the proposed method and compared with the results from other existing methods. Then, the method is further experimentally validated with two actual ultrasonic transducers used for flow measurement in our lab. The amplitude change of the output voltage signal from the receiver transducer due to changing the relative position of the two transducers is calculated by the proposed method and compared with the experimental data. This method can also provide the basis for complex multi-physical coupling computations where the effect of the acoustic field should be taken into account.

  12. Structural model of standard ultrasonic transducer array developed for FEM analysis of mechanical crosstalk.

    Science.gov (United States)

    Celmer, M; Opieliński, K J; Dopierała, M

    2018-02-01

    One of the reasons of distortions in ultrasonic imaging are crosstalk effects. They can be divided into groups according to the way of their formation. One of them is constituted by mechanical crosstalk, which is propagated by a construction of a multi-element array of piezoelectric transducers. When an individual transducer is excited, mechanical vibrations are transferred to adjacent construction components, thereby stimulating neighboring transducers to an undesired operation. In order to explore ways of the propagation of such vibrations, the authors developed the FEM model of the array of piezoelectric transducers designed for calculations in COMSOL Multiphysics software. Simulations of activating individual transducers and calculated electrical voltages appearing on transducers unstimulated intentionally, were performed in the time domain in order to assess the propagation velocity of different vibration modes through the construction elements. On this basis, conclusions were drawn in terms of the participation of various construction parts of the array of piezoelectric transducers in the process of creating the mechanical crosstalk. The elaborated FEM model allowed also to examine the ways aimed at reducing the transmission of mechanical crosstalk vibrations through the components of the array. Studies showed that correct cuts in the fasteners and the front layer improve the reduction of the mechanical crosstalk effect. The model can become a helpful tool in the process of design and modifications of manufactured ultrasonic arrays particularly in terms of mechanical crosstalk reduction. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. A cusp supporting framework design can decrease critical stresses in veneered molar crowns.

    Science.gov (United States)

    Kirsten, Armin; Parkot, Daniel; Raith, Stefan; Fischer, Horst

    2014-03-01

    Veneered zirconia restorations predominately fail due to veneering fractures. It is hypothesized that a cusp-supporting framework design can prevent these catastrophic failures in all-ceramic restorations. Therefore, we investigated the influence of framework design and framework material on the stress distribution in a single tooth restoration using the numerical finite element method. A three-dimensional model of a veneered lower molar (36) crown with constant outer shape was used. The framework design was either cusp supporting or with a constant framework thickness. Zirconia, alumina, and a gold alloy were used as framework material. A glass ceramic material was used as veneering material for both cases. Two different load cases were simulated: terminal occlusion with load distributed over the occlusal surface of the tooth and a fairly extreme load case with all force concentrated on one cusp. Maximum tensile stresses in the glass ceramic veneering material concentrated in the fissure region for all models. A cusp supporting framework design decreased the maximum tensile stresses significantly up to 30.5%. The distolingual load case resulted in an approximately fourfold higher stress level compared to the terminal occlusion load case. A cusp supporting framework design can significantly decrease the maximum tensile stresses in the veneering material of single crowns. Based on the numerical results of this study it can be expected that such a design could decrease the risk of veneering failure in vivo. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  14. Development and optimization of psychological stress model in mice using 2 level full factorial design.

    Science.gov (United States)

    Kala, Manika; Shaikh, Muhammad Vaseem; Nivsarkar, Manish

    Psychological stress has long been a silent killer, impairing normal physiological functions and leading to a variety of diseased conditions. However, the existing animal models for studying psychological stress have been marred by their inherent limitations warranting further research in their development and optimization. In this study 2 5 full factorial design was utilized for the development and optimization of psychological stress model in mice by applying different stressors viz., slanted cage(X 1 ), restraint(X 2 ), no bedding(X 3 ), dirty bedding(X 4 ) and isolation(X 5 ) at two time duration levels of 30 and 60min. The development of behavioral changes like depression, anxiety and anhedonia was taken as criteria for development of stress. These responses were analyzed using Design Expert 7.1.6. (Stat-Ease, Inc., USA). The maximum effective responses obtained were taken as a criterion for optimization. The optimized model was applied to measure the change in serum cortisol level to confirm the stress development. The statistical data showed that a quadratic model was fitted to the data obtained. All the factors were found to have a significant role in the development of stress among which restraint, slanted cage and dirty bedding were found to be more causal (pstressed mice of optimized model (ppsychological stress development in mice. The study could lay a strong platform for the use of quality by design approach in the development of robust, efficient and resourceful animal models. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Thermal stress and creep fatigue limitations in first wall design

    International Nuclear Information System (INIS)

    Majumdar, S.; Misra, B.; Harkness, S.D.

    1977-01-01

    The thermal-hydraulic performance of a lithium cooled cylindrical first wall module has been analyzed as a function of the incident neutron wall loading. Three criteria were established for the purpose of defining the maximum wall loading allowable for modules constructed of Type 316 stainless steel and a vanadium alloy. Of the three, the maximum structural temperature criterion of 750 0 C for vanadium resulted in the limiting wall loading value of 7 MW/m 2 . The second criterion limited thermal stress levels to the yield strength of the alloy. This led to the lowest wall loading value for the Type 316 stainless steel wall (1.7 MW/m 2 ). The third criterion required that the creep-fatigue characteristics of the module allow a lifetime of 10 MW-yr/m 2 . At wall temperatures of 600 0 C, this lifetime could be achieved in a stainless steel module for wall loadings less than 3.2 MW/m 2 , while the same lifetime could be achieved for much higher wall loadings in a vanadium module

  16. The application of excess shear stress to the design of mine layouts

    Energy Technology Data Exchange (ETDEWEB)

    Napier, J.A.L.

    1987-12-01

    The application of excess shear stress as an aid to the design of mine layout is reviewed, and the critical parameters required to describe slip on a plane of weakness are noted. A design procedure that is required to model the cyclic build-up of excess shear stress is described. A number of simple examples of mine layouts on two reef planes intersecting a fault plane are then considered to illustrate the application of the design concept and to highlight some of the pitfalls that may be encountered. 7 refs., 10 figs., 2 tabs.

  17. Interior design for ambulatory care facilities: how to reduce stress and anxiety in patients and families.

    Science.gov (United States)

    Frasca-Beaulieu, K

    1999-01-01

    The following article illustrates some important factors to consider when designing ambulatory care facilities (ACFs), and focuses on how wayfinding, noise control, privacy, security, color and lighting, general ambience, textures, and nature can have a profound influence on patient and family stress, consumer satisfaction, health and well-being. Other important design issues: convenience and accessibility, accommodation to various populations, consumer and family focus, patient education, image, as well as current equipment needs and future growth are examined in light of the prevailing trends in health care delivery. In sum, this feature explores the important stress-reducing and health-promoting elements involved in successful ACF design.

  18. An ultrasonic orthopaedic surgical device based on a cymbal transducer.

    Science.gov (United States)

    Bejarano, Fernando; Feeney, Andrew; Wallace, Robert; Simpson, Hamish; Lucas, Margaret

    2016-12-01

    An ultrasonic orthopaedic surgical device is presented, where the ultrasonic actuation relies on a modification of the classical cymbal transducer. All current devices consist of a Langevin ultrasonic transducer with a tuned cutting blade attached, where resonance is required to provide sufficient vibrational amplitude to cut bone. However, this requirement restricts the geometry and offers little opportunity to propose miniaturised devices or complex blades. The class V flextensional cymbal transducer is proposed here as the basis for a new design, where the cymbal delivers the required vibrational amplitude, and the design of the attached cutting insert can be tailored for the required cut. Consequently, the device can be optimised to deliver an accurate and precise cutting capability. A prototype device is presented, based on the cymbal configuration and designed to operate at 25.5kHz with a displacement amplitude of 30μm at 300V. Measurements of vibrational and impedance responses elucidate the mechanical and electrical characteristics of the device. Subsequent cutting tests on rat femur demonstrate device performance consistent with a commercial Langevin-based ultrasonic device and show that cutting is achieved using less electrical power and a lower piezoceramic volume. Histological analysis exhibits a higher proportion of live cells in the region around the cut site for the cymbal device than for a powered sagittal or a manual saw, demonstrating the potential for the ultrasonic device to result in faster healing. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Review of piezoelectric micromachined ultrasonic transducers and their applications

    Science.gov (United States)

    Jung, Joontaek; Lee, Wonjun; Kang, Woojin; Shin, Eunjung; Ryu, Jungho; Choi, Hongsoo

    2017-11-01

    In recent decades, micromachined ultrasonic transducers (MUTs) have been investigated as an alternative to conventional piezocomposite ultrasonic transducers, primarily due to the advantages that microelectromechanical systems provide. Miniaturized ultrasonic systems require ultrasonic transducers integrated with complementary metal-oxide-semiconductor circuits. Hence, piezoelectric MUTs (pMUTs) and capacitive MUTs (cMUTs) have been developed as the most favorable solutions. This paper reviews the basic equations to understand the characteristics of thin-film-based piezoelectric devices and presents recent research on pMUTs, including current approaches and limitations. Methods to improve the coupling coefficient of pMUTs are also investigated, such as device structure, materials, and fabrication techniques. The device structure improvements include multielectrode pMUTs, partially clamped boundary conditions, and 3D pMUTs (curved and domed types), where the latter can provide an electromechanical coupling coefficient of up to 45%. The piezoelectric coefficient (e 31) can be increased by controlling the crystal texture (seed layer of γ-Al2O3), using single-crystal (PMN-PT) materials, or control of residual stresses (using SiO2 layer). Arrays of pMUTs can be implemented for various applications including intravascular ultrasound, fingerprint sensors, rangefinders in air, and wireless power supply systems. pMUTs are expected to be an ideal solution for applications such as mobile biometric security (fingerprint sensors) and rangefinders due to their superior power efficiency and compact size.

  20. Review of piezoelectric micromachined ultrasonic transducers and their applications

    International Nuclear Information System (INIS)

    Jung, Joontaek; Lee, Wonjun; Kang, Woojin; Shin, Eunjung; Choi, Hongsoo; Ryu, Jungho

    2017-01-01

    In recent decades, micromachined ultrasonic transducers (MUTs) have been investigated as an alternative to conventional piezocomposite ultrasonic transducers, primarily due to the advantages that microelectromechanical systems provide. Miniaturized ultrasonic systems require ultrasonic transducers integrated with complementary metal-oxide-semiconductor circuits. Hence, piezoelectric MUTs (pMUTs) and capacitive MUTs (cMUTs) have been developed as the most favorable solutions. This paper reviews the basic equations to understand the characteristics of thin-film-based piezoelectric devices and presents recent research on pMUTs, including current approaches and limitations. Methods to improve the coupling coefficient of pMUTs are also investigated, such as device structure, materials, and fabrication techniques. The device structure improvements include multielectrode pMUTs, partially clamped boundary conditions, and 3D pMUTs (curved and domed types), where the latter can provide an electromechanical coupling coefficient of up to 45%. The piezoelectric coefficient ( e 31 ) can be increased by controlling the crystal texture (seed layer of γ -Al 2 O 3 ), using single-crystal (PMN-PT) materials, or control of residual stresses (using SiO 2 layer). Arrays of pMUTs can be implemented for various applications including intravascular ultrasound, fingerprint sensors, rangefinders in air, and wireless power supply systems. pMUTs are expected to be an ideal solution for applications such as mobile biometric security (fingerprint sensors) and rangefinders due to their superior power efficiency and compact size. (topical review)

  1. A review of creep analysis and design under multi-axial stress states

    International Nuclear Information System (INIS)

    Yao, H.-T.; Xuan Fuzhen; Wang Zhengdong; Tu Shantung

    2007-01-01

    The existence of multi-axial states of stress cannot be avoided in elevated temperature components. It is essential to understand the associated failure mechanisms and to predict the lifetime in practice. Although metal creep has been studied for about 100 years, many problems are still unsolved, in particular for those involving multi-axial stresses. In this work, a state-of-the-art review of creep analysis and engineering design is carried out, with particular emphasis on the effect of multi-axial stresses. The existing theories and creep design approaches are grouped into three categories, i.e., the classical plastic theory (CPT) based approach, the cavity growth mechanism (CGM) based approach and the continuum damage mechanics (CDM) based approach. Following above arrangements, the constitutive equations and design criteria are addressed. In the end, challenges on the precise description of the multi-axial creep behavior and then improving the strength criteria in engineering design are presented

  2. Irregular Implant Design Decreases Periimplant Stress and Strain Under Oblique Loading.

    Science.gov (United States)

    He, Ling; Zhang, Jiwu; Li, Xiucheng; Hu, Hongcheng; Lu, Songhe; Tang, Zhihui

    2017-10-01

    To investigate whether a different implant geometry with the same potential contact surface area (PCSA) affects the principal stress and strains in bone. Three-dimensional finite-element models were created with a single endosseous implant embedded in bone. The irregular (IR) dental root-analog implant and regular (R) cylindrical implant with the same PCSA 350 mm were modeled, keeping the size of the thinnest implant wall 0.8 mm, and the thinnest bone wall 1 mm. The regular or irregular abutments were either 4.5 mm lower than the platform of the implants or 5 mm higher than the platform of the implants, both with the taper 1.44°. A 100 N vertical or 100 N vertical/50 N horizontal occlusal loading was applied. The biomechanical behaviors of periimplant bone were recorded. The IR implant design experienced lower periimplant stress and strain under oblique loading than that of R implant design. In the IR implant design, comparable stress in bone, implant, and abutment were found under 100 N vertical loading or 100 N vertical/50 N horizontal loading. In the R implant design, much higher stress in bone, implant, and abutment were found under 100 N vertical/50 N horizontal loading than that under 100 N vertical loading. Irregular dental root-analog implant is a biomechanically favorable design principle for decreasing periimplant stress and strain under oblique loading.

  3. Frequency Steered Acoustic Transducer, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase II project is to fabricate, characterize, and verify performance of a new type of frequency steered acoustic transducer...

  4. Frequency Steered Acoustic Transducer, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project is to develop, fabricate, and characterize a novel frequency steered acoustic transducer (FSAT) for the...

  5. Progress towards developing neutron tolerant magnetostrictive and piezoelectric transducers

    Science.gov (United States)

    Reinhardt, Brian; Tittmann, Bernhard; Rempe, Joy; Daw, Joshua; Kohse, Gordon; Carpenter, David; Ames, Michael; Ostrovsky, Yakov; Ramuhalli, Pradeep; Montgomery, Robert; Chien, Hualte; Wernsman, Bernard

    2015-03-01

    Current generation light water reactors (LWRs), sodium cooled fast reactors (SFRs), small modular reactors (SMRs), and next generation nuclear plants (NGNPs) produce harsh environments in and near the reactor core that can severely tax material performance and limit component operational life. To address this issue, several Department of Energy Office of Nuclear Energy (DOE-NE) research programs are evaluating the long duration irradiation performance of fuel and structural materials used in existing and new reactors. In order to maximize the amount of information obtained from Material Testing Reactor (MTR) irradiations, DOE is also funding development of enhanced instrumentation that will be able to obtain in-situ, real-time data on key material characteristics and properties, with unprecedented accuracy and resolution. Such data are required to validate new multi-scale, multi-physics modeling tools under development as part of a science-based, engineering driven approach to reactor development. It is not feasible to obtain high resolution/microscale data with the current state of instrumentation technology. However, ultrasound-based sensors offer the ability to obtain such data if it is demonstrated that these sensors and their associated transducers are resistant to high neutron flux, high gamma radiation, and high temperature. To address this need, the Advanced Test Reactor National Scientific User Facility (ATR-NSUF) is funding an irradiation, led by PSU, at the Massachusetts Institute of Technology Research Reactor to test the survivability of ultrasound transducers. As part of this effort, PSU and collaborators have designed, fabricated, and provided piezoelectric and magnetostrictive transducers that are optimized to perform in harsh, high flux, environments. Four piezoelectric transducers were fabricated with either aluminum nitride, zinc oxide, or bismuth titanate as the active element that were coupled to either Kovar or aluminum waveguides and two

  6. Ultrasonic transducer for extreme temperature environments

    Science.gov (United States)

    Light, Glenn M.; Cervantes, Richard A.; Alcazar, David G.

    1993-03-23

    An ultrasonic piezoelectric transducer that is operable in very high and very low temperatures. The transducer has a dual housing structure that isolates the expansion and contraction of the piezoelectric element from the expansion and contraction of the housing. Also, the internal components are made from materials having similar coefficients of expansion so that they do not interfere with the motion of the piezoelectric element.

  7. Finite element analysis of the influence of geometry and design of zirconia crowns on stress distribution.

    Science.gov (United States)

    Anami, Lilian Costa; Lima, Julia Magalhaes da Costa; Corazza, Pedro Henrique; Yamamoto, Eron Toshio Colauto; Bottino, Marco Antonio; Borges, Alexandre Luiz Souto

    2015-02-01

    To evaluate the influence of the geometry and design of prosthetic crown preparations on stress distribution in compression tests, using finite element analysis (FEA). Six combinations of 3D drawings of all-ceramic crowns (yttria-stabilized zirconia framework and porcelain veneer) were evaluated: F, flat preparation and simplified crown; FC, flat preparation and crown with contact point; FCM, flat preparation and modified crown; A, anatomical preparation and simplified anatomical crown framework; AC, anatomical preparation and crown with contact point; and ACM, anatomical preparation and modified crown. Bonded contact types at all interfaces with the mesh were assigned, and the material properties used were according to the literature. A 200 N vertical load was applied at the center of each model. The maximum principal stresses were quantitatively and qualitatively analyzed. The highest values of tensile stress were observed at the interface between the ceramics in the region under the load application for the simplified models (F and A). Reductions in stress values were observed for the model with the anatomical preparation and modified infrastructure (ACM). The stress distribution in the flat models was similar to that of their respective anatomical models. The modified design of the zirconia coping reduces the stress concentration at the interface with the veneer ceramic, and the simplified preparation can exert a stress distribution similar to that of the anatomical preparation at and near the load point, when load is applied to the center of the crown. © 2014 by the American College of Prosthodontists.

  8. Ultrasound transducer disinfection in emergency medicine practice

    Directory of Open Access Journals (Sweden)

    Riley Hoyer

    2016-04-01

    Full Text Available Abstract Background External ultrasound transducer disinfection is common practice in medicine. Unfortunately, clinically significant organisms, such as methicillin-resistant Staphylococcus aureus (MRSA, Pseudomonas aeruginosa, and Klebsiella pneumonia spread throughout healthcare facilities via direct contact despite disinfection protocols. Ultrasound transducers and coupling gel provide potential vectors for pathogen transmission, especially in immunocompromised and high-risk patient populations. Our objective was to conduct a survey to investigate the variety of cleaning solutions or sanitary wipes used and evaluate current standard practice for transducer disinfection across emergency medicine training programs in the United States. Findings Eighty-three academic emergency medicine programs participated in this study. Eighty-seven percent (95 % CI 80–94 % of responding programs do not have a mandated protocol or standard contact time for transducer disinfection. Ninety percent (95 % CI 84–96 % of institutions use disinfectant solution or disinfectant wipes, as the standard of practice, to cleanse ultrasound transducers after every use. Conclusions Currently, there is a great deal of variability with regard to non-endocavitary transducer disinfection protocols that seems to stem from the vast number of disinfectant products and ultrasound manufacturer disparate recommendations. In order to mitigate risk to patients and reduce health care costs linked to nosocomial infections; healthcare providers, ultrasound companies, and disinfectant manufacturers must develop a universal use disinfectant and a standard protocol for ultrasound device disinfection for noncritical device disinfection in the emergency department.

  9. Ultrasound transducer disinfection in emergency medicine practice.

    Science.gov (United States)

    Hoyer, Riley; Adhikari, Srikar; Amini, Richard

    2016-01-01

    External ultrasound transducer disinfection is common practice in medicine. Unfortunately, clinically significant organisms, such as methicillin-resistant Staphylococcus aureus (MRSA), Pseudomonas aeruginosa, and Klebsiella pneumonia spread throughout healthcare facilities via direct contact despite disinfection protocols. Ultrasound transducers and coupling gel provide potential vectors for pathogen transmission, especially in immunocompromised and high-risk patient populations. Our objective was to conduct a survey to investigate the variety of cleaning solutions or sanitary wipes used and evaluate current standard practice for transducer disinfection across emergency medicine training programs in the United States. Eighty-three academic emergency medicine programs participated in this study. Eighty-seven percent (95 % CI 80-94 %) of responding programs do not have a mandated protocol or standard contact time for transducer disinfection. Ninety percent (95 % CI 84-96 %) of institutions use disinfectant solution or disinfectant wipes, as the standard of practice, to cleanse ultrasound transducers after every use. Currently, there is a great deal of variability with regard to non-endocavitary transducer disinfection protocols that seems to stem from the vast number of disinfectant products and ultrasound manufacturer disparate recommendations. In order to mitigate risk to patients and reduce health care costs linked to nosocomial infections; healthcare providers, ultrasound companies, and disinfectant manufacturers must develop a universal use disinfectant and a standard protocol for ultrasound device disinfection for noncritical device disinfection in the emergency department.

  10. TORCs: transducers of regulated CREB activity.

    Science.gov (United States)

    Conkright, Michael D; Canettieri, Gianluca; Screaton, Robert; Guzman, Ernesto; Miraglia, Loren; Hogenesch, John B; Montminy, Marc

    2003-08-01

    The cAMP responsive factor CREB stimulates gene expression, following its phosphorylation at Ser133, via recruitment of the coactivator CBP. In certain cell types, CREB also functions as a constitutive activator, although the underlying mechanisms are not understood. Here, we characterize a conserved family of coactivators, designated TORCs, for Transducers of Regulated CREB activity, that enhances CRE-dependent transcription via a phosphorylation-independent interaction with the bZIP DNA binding/dimerization domain of CREB. TORC recruitment does not appear to modulate CREB DNA binding activity, but rather enhances the interaction of CREB with the TAF(II)130 component of TFIID following its recruitment to the promoter. Remarkably, in certain mucoepidermoid carcinomas, a chromosomal translocation fuses the CREB binding domain of TORC1 to the Notch coactivator Mastermind (MAML2). As expression of the TORC1-MAML2 chimera strongly induced target gene expression via CREB, our results reveal a mechanism by which CREB stimulates transcription in normal and transformed cells.

  11. Mechanical-Stress Analytical Modeling for the Design of Coils in Power Applications

    Directory of Open Access Journals (Sweden)

    Bellan D.

    2014-12-01

    Full Text Available Modern electrical-power systems are often exploited for transmitting high-frequency carrier signals for communications purposes. Series-connected air-core coils represent the fundamental component allowing such applications by providing a proper filtering in the frequency domain. They must be designed, however, to withstand also the line short-circuit current. When a high-magnitude current flows through a coil, strong mechanical stresses are produced within the conductor, leading to possible damage of the coil. In this paper, an approximate analytical model is derived for the relationship between the maximum mechanical stress and the electrical/geometrical parameters of the coil. Such a model provides the guidelines for a fast and safe coil design, whereas numerical simulations are only needed for the design refinement. The presented approach can be extended to other applications such as, for example, the mechanical stress resulting from the inrush currents in the coils of power transformers.

  12. RESEARCH INTO VALVE-ENGINE TRANSDUCERS OF BRUSHLESS SYNCHRONOUS AND ASYNCHRONIZED MACHINES IN A CIRCUIT SIMULATION SYSTEM.

    Directory of Open Access Journals (Sweden)

    A.M. Galynovskiy

    2013-10-01

    Full Text Available Designing features for valve-engine transducers of brushless synchronous and asynchronized machines are described. Global analysis of research results on the transducer models in a MicroCap circuit simulation system is made, recommendations on the simulation system application in both scientific research and educational process given.

  13. Elevated temperature design of KALIMER reactor internals accounting for creep and stress-rupture effects

    International Nuclear Information System (INIS)

    Koo, Gyeong Hoi; Yoo, Bong

    2000-01-01

    In most LMFBR (Liquid Metal Fast Breed Reactor) design, the operating temperature is very high and the time-dependent creep and stress-rupture effects become so important in reactor structural design. Therefore, unlike with conventional PWR, the normal operating conditions can be basically dominant design loading because the hold time at elevated temperature condition is so long and enough to result in severe total creep ratcheting strains during total service lifetime. In this paper, elevated temperature design of the conceptually designed baffle annulus regions of KALIMER (Korea Advanced Liquid Metal Reactor) reactor internal structures is carried out for normal operating conditions which have the operating temperature 530 deg. C and the total service lifetime of 30 years. For the elevated temperature design of reactor internal structures, the ASME Code Case N-201-4 is used. Using this code, the time-dependent stress limits, the accumulated total inelastic strain during service lifetime, and the creep-fatigue damages are evaluated with the calculation results by the elastic analysis under conservative assumptions. The application procedures of elevated temperature design of the reactor internal structures using ASME code case N-201-4 with the elastic analysis method are described step by step in detail. This paper will be useful guide for actual application of elevated temperature design of various reactor types accounting for creep and stress-rupture effects. (author)

  14. Design of reinforced concrete walls casted in place for the maximum normal stress of compression

    Directory of Open Access Journals (Sweden)

    T. C. Braguim

    Full Text Available It is important to evaluate which designing models are safe and appropriate to structural analysis of buildings constructed in Concrete Wall system. In this work it is evaluated, through comparison of maximum normal stress of compression, a simple numerical model, which represents the walls with frame elements, with another much more robust and refined, which represents the walls with shells elements. The designing of the normal stress of compression it is done for both cases, based on NBR 16055, to conclude if the wall thickness initially adopted, it is enough or not.

  15. Surface Acoustic Wave Transducer Study.

    Science.gov (United States)

    1978-05-01

    ment. — ISO Lir — ~.1 L ~~~~~~~~ ~ ~~~ L~~~I&jr ~~ —- — — —--- - - - - t - s’ rlr ~~T I O , 4 ) F ~ H I ’ ~~,! ~WI.ft ?).s. ~~~~MEPORT DOCUMENTAT I...multiplying the norma l stress components thus ensuring that the normal stress is zero at x 2 = 0. For the present , an open-circuit elec trical...boundary condition is assumed so that the norma l D-uield is zero at the surface. This is taken .5 into account in a similar manner with a step-function

  16. Designing, Prototyping and Evaluating Digital Mindfulness Applications: A Case Study of Mindful Breathing for Stress Reduction.

    Science.gov (United States)

    Zhu, Bin; Hedman, Anders; Feng, Shuo; Li, Haibo; Osika, Walter

    2017-06-14

    During the past decade, there has been a rapid increase of interactive apps designed for health and well-being. Yet, little research has been published on developing frameworks for design and evaluation of digital mindfulness facilitating technologies. Moreover, many existing digital mindfulness applications are purely software based. There is room for further exploration and assessment of designs that make more use of physical qualities of artifacts. The study aimed to develop and test a new physical digital mindfulness prototype designed for stress reduction. In this case study, we designed, developed, and evaluated HU, a physical digital mindfulness prototype designed for stress reduction. In the first phase, we used vapor and light to support mindful breathing and invited 25 participants through snowball sampling to test HU. In the second phase, we added sonification. We deployed a package of probes such as photos, diaries, and cards to collect data from users who explored HU in their homes. Thereafter, we evaluated our installation using both self-assessed stress levels and heart rate (HR) and heart rate variability (HRV) measures in a pilot study, in order to measure stress resilience effects. After the experiment, we performed a semistructured interview to reflect on HU and investigate the design of digital mindfulness apps for stress reduction. The results of the first phase showed that 22 of 25 participants (88%) claimed vapor and light could be effective ways of promoting mindful breathing. Vapor could potentially support mindful breathing better than light (especially for mindfulness beginners). In addition, a majority of the participants mentioned sound as an alternative medium. In the second phase, we found that participants thought that HU could work well for stress reduction. We compared the effect of silent HU (using light and vapor without sound) and sonified HU on 5 participants. Subjective stress levels were statistically improved with both

  17. A distributed transducer system for functional electrical stimulation

    DEFF Research Database (Denmark)

    Gudnason, Gunnar; Nielsen, Jannik Hammel; Bruun, Erik

    2001-01-01

    Implanted transducers for functional electrical stimulation (FES) powered by inductive links are subject to conflicting requirements arising from low link efficiency, a low power budget and the need for protection of the weak signals against strong RF electromagnetic fields. We propose a solution...... to be affected by the inductive link. Neural stimulators are affected to a lesser degree, but still benefit from the partitioning. As a test case, we have designed a transceiver and a sensor chip which implement this partitioning policy. The transceiver is designed to operate in the 6.78 MHz ISM band...

  18. Design, fabrication and testing of a prototype stressed-shell fuel isolation container

    International Nuclear Information System (INIS)

    Crosthwaite, J.L.; Barrie, J.N.; Nuttall, K.

    1982-07-01

    Atomic Energy of Canada Limited is conducting and coordinating research into the development of engineered barriers for the disposal of unreprocessed irradiated fuel within a deep, stable geologic vault. In one approach, a containment shell of corrosion-resistant metal is proposed as the principal barrier to radionuclide release, giving a high probability of containment for at least 300 years, thus ensuring isolation of nearly all fission products for their hazardous lives. The simplest concept is the 'stressed-shell' container, designed with sufficient shell thickness to withstand the hydrostatic pressure within a 1000-m deep disposal vault postulated to have flooded with groundwater. This report describes the design, fabrication, analysis and hydrostatic testing of a full-scale stressed-shell prototype. The report concludes that the deformation and collapse performance of stressed-shell designs, based on short-term mechanical properties be modelled adequately by BOSOR 5, a commercially available stress-strain computer program. If the stressed-shell concept is retained as a viable fuel isolation concept, future analyses should include an assessment of the role of material creep on long-term container performance

  19. Design and fabrication of an apparatus to study stress corrosion cracking

    International Nuclear Information System (INIS)

    Buscarlet, Carol

    1977-01-01

    In this research thesis, the author first gives a large overview of tests methods of stress corrosion cracking: definition and generalities, stress corrosion cracking in the laboratory (test methods with imposed deformation, load or strain rate, theories of hydrogen embrittlement, of adsorption, of film breaking, and electrochemical theories), stress corrosion cracking in alkaline environment (in light water reactors, of austenitic stainless steels), and conventional tests on polycrystals and monocrystals of stainless steels in sodium hydroxide. The next parts address the core of this research, i.e. the design of an autoclave containing a tensile apparatus, the fabrication of this apparatus, the stress application device, the sample environment, pressurization, control and command, preliminary tests in a melt salt, and the first cracking tests [fr

  20. Tungsten Oxide Photonic Crystals as Optical Transducer for Gas Sensing.

    Science.gov (United States)

    Amrehn, Sabrina; Wu, Xia; Wagner, Thorsten

    2018-01-26

    Some metal oxide semiconductors, such as tungsten trioxide or tin dioxide, are well-known as resistive transducers for gas sensing and offer high sensitivities down to the part per billion level. Electrical signal read-out, however, limits the information obtained on the electronic properties of metal oxides to a certain frequency range and its application because of the required electrical contacts. Therefore, a novel approach for building an optical transducer for gas reactions utilizing metal oxide photonic crystals is presented here. By the rational design of the structure and composition it is possible to synthesize a functional material which allows one to obtain insight into its electronic properties in the optical frequency range with simple experimental measures. The concept is demonstrated by tungsten trioxide inverse opal structure as optical transducer material for hydrogen sensing. The sensing behavior is analyzed in a temperature range from room temperature to 500 °C and in a wide hydrogen concentration range (3000 ppm to 10%). The sensing mechanism is mainly the refractive index change resulting from hydrogen intercalation in tungsten trioxide, but the back reaction has also impact on the optical properties of this system. Detailed chemical reaction studies provide suggestions for specific sensing conditions.

  1. Electromechanically active polymer transducers: research in Europe

    Science.gov (United States)

    Carpi, Federico; Graz, Ingrid; Jager, Edwin; Ladegaard Skov, Anne; Vidal, Frédéric

    2013-10-01

    Smart materials and structures based on electromechanically active polymers (EAPs) represent a fast growing and stimulating field of research and development. EAPs are materials capable of changing dimensions and/or shape in response to suitable electrical stimuli. They are commonly classified in two major families: ionic EAPs (activated by an electrically induced transport of ions and/or solvent) and electronic EAPs (activated by electrostatic forces). These polymers show interesting properties, such as sizable active strains and/or stresses in response to electrical driving, high mechanical flexibility, low density, structural simplicity, ease of processing and scalability, no acoustic noise and, in most cases, low costs. Since many of these characteristics can also describe natural muscle tissues from an engineering standpoint, it is not surprising that EAP transducers are sometimes also referred to as 'muscle-like smart materials' or 'artificial muscles'. They are used not only to generate motion, but also to sense or harvest energy from it. In particular, EAP electromechanical transducers are studied for applications that can benefit from their 'biomimetic' characteristics, with possible usages from the micro- to the macro-scale, spanning several disciplines, such as mechatronics, robotics, automation, biotechnology and biomedical engineering, haptics, fluidics, optics and acoustics. Currently, the EAP field is just undergoing its initial transition from academic research into commercialization, with companies starting to invest in this technology and the first products appearing on the market. This focus issue is intentionally aimed at gathering contributions from the most influential European groups working in the EAP field. In fact, today Europe hosts the broadest EAP community worldwide. The rapid expansion of the EAP field in Europe, where it historically has strong roots, has stimulated the creation of the 'European Scientific Network for Artificial

  2. A new topological structure for the Langevin-type ultrasonic transducer.

    Science.gov (United States)

    Lu, Xiaolong; Hu, Junhui; Peng, Hanmin; Wang, Yuan

    2017-03-01

    In this paper, a new topological structure for the Langevin-type ultrasonic transducer is proposed and investigated. The two cylindrical terminal blocks are conically shaped with four supporting plates each, and two cooling fins are disposed at the bottom of terminal blocks, adjacent to the piezoelectric rings. Experimental results show that it has larger vibration velocity, lower temperature rise and higher electroacoustic energy efficiency than the conventional Langevin transducer. The reasons for the phenomena can be well explained by the change of mass, heat dissipation surface and force factor of the transducer. The proposed design may effectively improve the performance of ultrasonic transducers, in terms of the working effect, energy consumption and working life. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. High Temperature, High Power Piezoelectric Composite Transducers

    Directory of Open Access Journals (Sweden)

    Hyeong Jae Lee

    2014-08-01

    Full Text Available Piezoelectric composites are a class of functional materials consisting of piezoelectric active materials and non-piezoelectric passive polymers, mechanically attached together to form different connectivities. These composites have several advantages compared to conventional piezoelectric ceramics and polymers, including improved electromechanical properties, mechanical flexibility and the ability to tailor properties by using several different connectivity patterns. These advantages have led to the improvement of overall transducer performance, such as transducer sensitivity and bandwidth, resulting in rapid implementation of piezoelectric composites in medical imaging ultrasounds and other acoustic transducers. Recently, new piezoelectric composite transducers have been developed with optimized composite components that have improved thermal stability and mechanical quality factors, making them promising candidates for high temperature, high power transducer applications, such as therapeutic ultrasound, high power ultrasonic wirebonding, high temperature non-destructive testing, and downhole energy harvesting. This paper will present recent developments of piezoelectric composite technology for high temperature and high power applications. The concerns and limitations of using piezoelectric composites will also be discussed, and the expected future research directions will be outlined.

  4. High Temperature, High Power Piezoelectric Composite Transducers

    Science.gov (United States)

    Lee, Hyeong Jae; Zhang, Shujun; Bar-Cohen, Yoseph; Sherrit, StewarT.

    2014-01-01

    Piezoelectric composites are a class of functional materials consisting of piezoelectric active materials and non-piezoelectric passive polymers, mechanically attached together to form different connectivities. These composites have several advantages compared to conventional piezoelectric ceramics and polymers, including improved electromechanical properties, mechanical flexibility and the ability to tailor properties by using several different connectivity patterns. These advantages have led to the improvement of overall transducer performance, such as transducer sensitivity and bandwidth, resulting in rapid implementation of piezoelectric composites in medical imaging ultrasounds and other acoustic transducers. Recently, new piezoelectric composite transducers have been developed with optimized composite components that have improved thermal stability and mechanical quality factors, making them promising candidates for high temperature, high power transducer applications, such as therapeutic ultrasound, high power ultrasonic wirebonding, high temperature non-destructive testing, and downhole energy harvesting. This paper will present recent developments of piezoelectric composite technology for high temperature and high power applications. The concerns and limitations of using piezoelectric composites will also be discussed, and the expected future research directions will be outlined. PMID:25111242

  5. High temperature, high power piezoelectric composite transducers.

    Science.gov (United States)

    Lee, Hyeong Jae; Zhang, Shujun; Bar-Cohen, Yoseph; Sherrit, Stewart

    2014-08-08

    Piezoelectric composites are a class of functional materials consisting of piezoelectric active materials and non-piezoelectric passive polymers, mechanically attached together to form different connectivities. These composites have several advantages compared to conventional piezoelectric ceramics and polymers, including improved electromechanical properties, mechanical flexibility and the ability to tailor properties by using several different connectivity patterns. These advantages have led to the improvement of overall transducer performance, such as transducer sensitivity and bandwidth, resulting in rapid implementation of piezoelectric composites in medical imaging ultrasounds and other acoustic transducers. Recently, new piezoelectric composite transducers have been developed with optimized composite components that have improved thermal stability and mechanical quality factors, making them promising candidates for high temperature, high power transducer applications, such as therapeutic ultrasound, high power ultrasonic wirebonding, high temperature non-destructive testing, and downhole energy harvesting. This paper will present recent developments of piezoelectric composite technology for high temperature and high power applications. The concerns and limitations of using piezoelectric composites will also be discussed, and the expected future research directions will be outlined.

  6. Using the Universal Design for Learning Approach in Science Laboratories to Minimize Student Stress

    Science.gov (United States)

    Miller, Daniel K.; Lang, Patricia L.

    2016-01-01

    This commentary discusses how the principles of universal design for learning (UDL) can be applied in the science laboratory with an emphasis on assisting students who experience stress in the laboratory environment. The UDL approach in the laboratory is based on three elements: open-mindedness, supportive communication, and analysis and…

  7. Silicon pressure transducers: a review

    International Nuclear Information System (INIS)

    Aceves M, M.; Sandoval I, F.

    1994-01-01

    We present a review of the pressure sensors, which use the silicon piezo resistive effect and micro machining technique. Typical pressure sensors, applications, design and other different structures are presented. (Author)

  8. Modeling Displacement Measurement using Vibration Transducers

    Directory of Open Access Journals (Sweden)

    AGOSTON Katalin

    2014-05-01

    Full Text Available This paper presents some aspects regarding to small displacement measurement using vibration transducers. Mechanical faults, usages, slackness’s, cause different noises and vibrations with different amplitude and frequency against the normal sound and movement of the equipment. The vibration transducers, accelerometers and microphone are used for noise and/or sound and vibration detection with fault detection purpose. The output signal of the vibration transducers or accelerometers is an acceleration signal and can be converted to either velocity or displacement, depending on the preferred measurement parameter. Displacement characteristics are used to indicate when the machine condition has changed. There are many problems using accelerometers to measure position or displacement. It is important to determine displacement over time. To determinate the movement from acceleration a double integration is needed. A transfer function and Simulink model was determinate for accelerometers with capacitive sensing element. Using these models the displacement was reproduced by low frequency input.

  9. Immune Algorithm Complex Method for Transducer Calibration

    Directory of Open Access Journals (Sweden)

    YU Jiangming

    2014-08-01

    Full Text Available As a key link in engineering test tasks, the transducer calibration has significant influence on accuracy and reliability of test results. Because of unknown and complex nonlinear characteristics, conventional method can’t achieve satisfactory accuracy. An Immune algorithm complex modeling approach is proposed, and the simulated studies on the calibration of third multiple output transducers is made respectively by use of the developed complex modeling. The simulated and experimental results show that the Immune algorithm complex modeling approach can improve significantly calibration precision comparison with traditional calibration methods.

  10. Using XBee transducers for wireless data collection

    Science.gov (United States)

    Ayars, Eric; Lai, Estella

    2010-07-01

    This article describes how to use XBee transducers to create small and lightweight wireless sensors, which send data to a base station for collection and analysis. Data collection is limited to 10-bit accuracy by the XBee hardware. Depending on the type of XBee used, up to six data channels can be transmitted over a range of up to 15 miles. We describe the technical details of the process using the low-power version of the XBee transducer and a three-axis accelerometer chip.

  11. A new transducer for roll gap measurements of the roll pressure distribution and the friction condition in cold flat rolling

    DEFF Research Database (Denmark)

    Lagergren, Jonas; Wanheim, Tarras; Presz, W.

    2005-01-01

    and stainless steel strips in a pilot mill. The recordings were selected from a steady state with no disturbance from the material flow. The transducer was able to simultaneously measure both the normal pressure and the friction stress. An estimation of the coefficient of friction was accordingly performed....... Conclusions The new transducer works very well, it was seen to be robust and able to avoid signal disturbance. The pressure and friction stress distribution results was as expected by the authors and a good reproducibility, together with a proven agreement between recorded signals and signals simulated....... Keywords Friction stress, normal pressure distribution, roll bite measurements, cold flat rolling of metals...

  12. Stress management during pregnancy: designing and evaluating a mind-body intervention.

    Science.gov (United States)

    Jallo, Nancy; Bourguignon, Cheryl; Taylor, Ann Gill; Utz, Sharon W

    2008-01-01

    The objective of this 12-week study was to determine whether a relaxation-guided imagery (R-GI) intervention designed as a primary prevention strategy for stress management was perceived as beneficial to African American women during the second trimester of pregnancy. All participants documented perceived benefits of the R-GI intervention that included the following: (1) improved breathing; (2) ability to relax, clear one's mind, and become calm; (3) ability to channel and decrease stress; (4) release of anxiety; (5) use of R-GI throughout the day helped control anger and state of mind, leading to a smoother day; and (6) improved ability to fall and stay asleep.

  13. Cyclic stress-strain curve for low cycle fatigue design and development of small specimen technology

    International Nuclear Information System (INIS)

    Nishimura, A.; Nogami, S.; Wakai, Eiichi

    2012-11-01

    A blanket system in DEMO requires a low cycle fatigue design because higher inner pressure will act on a structural wall. An importance of cyclic stress-strain curve is investigated and necessity reason for a precise deformation measurement is discussed. Since a small specimen technique is necessary to investigate neutron irradiation effect, it is desired to establish a test procedure to obtain the stress-strain curve with small specimens. To do this, a new test procedure with nanometer scale resolution was developed and some data were obtained. (author)

  14. A hierarchical method for structural topology design problems with local stress and displacement constraints

    DEFF Research Database (Denmark)

    Stolpe, Mathias; Stidsen, Thomas K.

    2005-01-01

    In this paper we present a hierarchical optimization method for finding feasible true 0-1 solutions to finite element based topology design problems. The topology design problems are initially modeled as non-convex mixed 0-1 programs. The hierarchical optimization method is applied to the problem...... from global optimization, which have only recently become available, for solving the problems in the sequence. Numerical examples of topology design problems of continuum structures with local stress and displacement constraints are presented.......In this paper we present a hierarchical optimization method for finding feasible true 0-1 solutions to finite element based topology design problems. The topology design problems are initially modeled as non-convex mixed 0-1 programs. The hierarchical optimization method is applied to the problem...... of minimizing the weight of a structure subject to displacement and local design-dependent stress constraints. The method iteratively solves a sequence of problems of increasing size of the same type as the original problem. The problems are defined on a design mesh which is initially coarse...

  15. Air-Coupled Piezoelectric Transducers with Active Polypropylene Foam Matching Layers

    Directory of Open Access Journals (Sweden)

    Tomás E. Gómez Alvarez-Arenas

    2013-05-01

    Full Text Available This work presents the design, construction and characterization of air-coupled piezoelectric transducers using 1–3 connectivity piezocomposite disks with a stack of matching layers being the outer one an active quarter wavelength layer made of polypropylene foam ferroelectret film. This kind of material has shown a stable piezoelectric response together with a very low acoustic impedance (<0.1 MRayl. These features make them a suitable candidate for the dual use or function proposed here: impedance matching layer and active material for air-coupled transduction. The transducer centre frequency is determined by the l/4 resonance of the polypropylene foam ferroelectret film (0.35 MHz, then, the rest of the transducer components (piezocomposite disk and passive intermediate matching layers are all tuned to this frequency. The transducer has been tested in several working modes including pulse-echo and pitch-catch as well as wide and narrow band excitation. The performance of the proposed novel transducer is compared with that of a conventional air-coupled transducers operating in a similar frequency range.

  16. Stress Regression Analysis of Asphalt Concrete Deck Pavement Based on Orthogonal Experimental Design and Interlayer Contact

    Science.gov (United States)

    Wang, Xuntao; Feng, Jianhu; Wang, Hu; Hong, Shidi; Zheng, Supei

    2018-03-01

    A three-dimensional finite element box girder bridge and its asphalt concrete deck pavement were established by ANSYS software, and the interlayer bonding condition of asphalt concrete deck pavement was assumed to be contact bonding condition. Orthogonal experimental design is used to arrange the testing plans of material parameters, and an evaluation of the effect of different material parameters in the mechanical response of asphalt concrete surface layer was conducted by multiple linear regression model and using the results from the finite element analysis. Results indicated that stress regression equations can well predict the stress of the asphalt concrete surface layer, and elastic modulus of waterproof layer has a significant influence on stress values of asphalt concrete surface layer.

  17. The correct lens mount lightweighting design and thermal stress OPD analysis in Cassegrain telescope

    Science.gov (United States)

    Hsu, Ming-Ying; Chan, Chia-Yen; Lin, Wei-Cheng; Chang, Shenq-Tsong; Huang, Ting-Ming

    2013-09-01

    This study is trying to evaluate different lens barrel material, caused lens stress OPD (Optical Path Different) in different temperature condition. The Cassegrain telescope's correct lens assembly are including as correct lens, lens mount, spacer, mount barrel and retainer. The lens barrel initial design is made by invar, but system mass limit is need to lightweighting to meet requirement. Therefore, the lens barrel material is tried to replace to lower density material, such as aluminum and titanium alloy. Meanwhile, the aluminum or titanium alloy material properties CTE (Coefficient of Thermal Expansion) are larger then invar. Thus, the high CTE material will introduce larger thermal stress into the optical system in different temperature condition. This article is analysis the correct lens assembly thermal stress and optical performance in different lens mount material. From above conditions, using FEM (Finite Element Method) and optical software, simulation and optimization the lens mount to achieve system mass requirement.

  18. Bi-Metallic Composite Structures With Designed Internal Residual Stress Field

    Science.gov (United States)

    Brice, Craig A.

    2014-01-01

    Shape memory alloys (SMA) have a unique ability to recover small amounts of plastic strain through a temperature induced phase change. For these materials, mechanical displacement can be accomplished by heating the structure to induce a phase change, through which some of the plastic strain previously introduced to the structure can be reversed. This paper introduces a concept whereby an SMA phase is incorporated into a conventional alloy matrix in a co-continuous reticulated arrangement forming a bi-metallic composite structure. Through memory activation of the mechanically constrained SMA phase, a controlled residual stress field is developed in the interior of the structure. The presented experimental data show that the memory activation of the SMA composite component significantly changes the residual stress distribution in the overall structure. Designing the structural arrangement of the two phases to produce a controlled residual stress field could be used to create structures that have much improved durability and damage tolerance properties.

  19. Effect of geometric construction on residual stress distribution in designing a nuclear rotor joined by multipass narrow gap welding

    International Nuclear Information System (INIS)

    Tan, Long; Zhang, Linjie; Zhang, Jianxun; Zhuang, Dong

    2014-01-01

    Highlights: • The internal stress of the pipe is measured using local material removal method. • Bottom protrusion at weld seam can release the stress and mitigate stress evolution. The through-wall axial stress is bending type under the effect of the rotor discs. • The impact of geometric construction on the stress evolution begins after pass 15. - Abstract: The purpose of this study is to investigate the effect of geometric construction on the distribution of residual stresses before and after heat treatment in designing a nuclear welded rotor. The local material removal method was used to measure internal residual stress of the experimental pipe after post weld heat treatment. Three finite element models were employed as follows: a model of experimental pipe, a model with a bottom protrusion existed at the weld region, and a model of two rotor discs butt-welded with a bottom protrusion at the weld region. Investigated results showed that the bottom protrusion existed at the weld region can decrease the residual stress and mitigate the stress evolution significantly on the inner surface. Under the binding effect of the rotor discs, the axial stress of inner surface region is compressive stress; the through-wall axial stress at the weld center line can be deemed to a bending type; both the hoop stress and axial stress at the weld center line on the inner surface are compressive. The impact of geometric construction on the stress evolution at the root bead begins after pass 15 deposited

  20. Ferroelectret non-contact ultrasonic transducers

    Czech Academy of Sciences Publication Activity Database

    Bovtun, Viktor; Döring, J.; Bartusch, J.; Beck, U.; Erhard, A.; Yakymenko, Y.

    2007-01-01

    Roč. 88, č. 4 (2007), s. 737-743 ISSN 0947-8396 R&D Projects: GA ČR(CZ) GA202/06/0403 Institutional research plan: CEZ:AV0Z10100520 Keywords : ferroelectrets * polymers * ultrasonic transducers Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.857, year: 2007

  1. Linearization of resistance thermometers and other transducers

    DEFF Research Database (Denmark)

    Diamond, Joseph M.

    1970-01-01

    deflection output or to null balance output. The application to the common temperature transducers is considered. It is shown that thermistors, linear metals (e.g., copper), and nickel can be linearized in terms of temperature, but platinum cannot be. If linearization is desired in terms of the reciprocal...

  2. Pushdown machines for the macro tree transducer

    NARCIS (Netherlands)

    Engelfriet, Joost; Vogler, Heiko

    1986-01-01

    The macro tree transducer can be considered as a system of recursive function procedures with parameters, where the recursion is on a tree (e.g., the syntax tree of a program). We investigate characterizations of the class of tree (tree-to-string) translations which is induced by macro tree

  3. Eliminating transducer distortion in acoustic measurements

    DEFF Research Database (Denmark)

    Agerkvist, Finn T.; Torras Rosell, Antoni; McWalter, Richard Ian

    2014-01-01

    This paper investigates the in uence of nonlinear components that contaminate the linear response of acoustic transducer, and presents a method for eliminating the in uence of nonlinearities in acoustic measurements. The method is evaluated on simulated as well as experimental data, and is shown ...

  4. Optimal design of the gerotor (2-ellipses) for reducing maximum contact stress

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Hyo Seo; Li, Sheng Huan [Dept. of Mechanical Convergence Technology, Pusan National University, Busan (Korea, Republic of); Kim, Chul [School of Mechanical Design and Manufacturing, Busan Institute of Science and Technology, Busan (Korea, Republic of)

    2016-12-15

    The oil pump, which is used as lubricator of engines and auto transmission, supplies working oil to the rotating elements to prevent wear. The gerotor pump is used widely in the automobile industry. When wear occurs due to contact between an inner rotor and an outer rotor, the efficiency of the gerotor pump decreases rapidly, and elastic deformation from the contacts also causes vibration and noise. This paper reports the optimal design of a gerotor with a 2-ellipses combined lobe shape that reduces the maximum contact stress. An automatic program was developed to calculate Hertzian contact stress of the gerotor using the Matlab and the effect of the design parameter on the maximum contact stress was analyzed. In addition, the method of theoretical analysis for obtaining the contact stress was verified by performing the fluid-structural coupled analysis using the commercial software, Ansys, considering both the driving force of the inner rotor and the fluid pressure, which is generated by working oil.

  5. Ferrule Designs and Stress Distribution in Endodontically Treated Upper Central Incisors: 3D Finite Element Analysis

    Directory of Open Access Journals (Sweden)

    A. Hassan Ahangari

    2008-09-01

    Full Text Available Objective: The main goal of this study was to evaluate stress distribution of endodonti-cally treated maxillary central incisors restored with glass fiber posts, composite resin cores, and crowns with different ferrule designs.Materials and Methods: Four three-dimensional models of a maxillary central incisor were modeled in SolidWorks 2006. Tooth with no ferrule, tooth with a 2 mm circumferen-tial ferrule, tooth with a 2 mm beveled ferrule and tooth with a 0.5 mm circumferential ferrule. The teeth were restored with glass fiber posts, composite resin cores, and full ce-ramics crowns. Each model was loaded (1 N on the palatal side at an angle of 45 degrees to tooth long axis. Von Mises stress findings along the inner surface of the root canals were assessed and compared.Results: The Von Mises Stress at CEJ was the highest in the model without a ferrule when compared to the other models (without ferrule 0.0696, short ferrule 0.0492, cylindrical fer-rule 0.0248, and beveled ferrule 0.0387 MPa.Conclusion: Endodontically treated maxillary central incisors with a ferrule length vary-ing between 0.5 mm and 2.0 mm exhibit lower stress distribution compared to those with-out a ferrule. Keeping a long ferrule is suggested to decrease the stress at the cervical area of restored teeth.

  6. Non-linear analysis and the design of Pumpkin Balloons: stress, stability and viscoelasticity

    Science.gov (United States)

    Rand, J. L.; Wakefield, D. S.

    Tensys have a long-established background in the shape generation and load analysis of architectural stressed membrane structures Founded upon their inTENS finite element analysis suite these activities have broadened to encompass lighter than air structures such as aerostats hybrid air-vehicles and stratospheric balloons Winzen Engineering couple many years of practical balloon design and fabrication experience with both academic and practical knowledge of the characterisation of the non-linear viscoelastic response of the polymeric films typically used for high-altitude scientific balloons Both companies have provided consulting services to the NASA Ultra Long Duration Balloon ULDB Program Early implementations of pumpkin balloons have shown problems of geometric instability characterised by improper deployment and these difficulties have been reproduced numerically using inTENS The solution lies in both the shapes of the membrane lobes and also the need to generate a biaxial stress field in order to mobilise in-plane shear stiffness Balloons undergo significant temperature and pressure variations in flight The different thermal characteristics between tendons and film can lead to significant meridional stress Fabrication tolerances can lead to significant local hoop stress concentrations particularly adjacent to the base and apex end fittings The non-linear viscoelastic response of the envelope film acts positively to help dissipate stress concentrations However creep over time may produce lobe geometry variations that may

  7. Biasing of Capacitive Micromachined Ultrasonic Transducers.

    Science.gov (United States)

    Caliano, Giosue; Matrone, Giulia; Savoia, Alessandro Stuart

    2017-02-01

    Capacitive micromachined ultrasonic transducers (CMUTs) represent an effective alternative to piezoelectric transducers for medical ultrasound imaging applications. They are microelectromechanical devices fabricated using silicon micromachining techniques, developed in the last two decades in many laboratories. The interest for this novel transducer technology relies on its full compatibility with standard integrated circuit technology that makes it possible to integrate on the same chip the transducers and the electronics, thus enabling the realization of extremely low-cost and high-performance devices, including both 1-D or 2-D arrays. Being capacitive transducers, CMUTs require a high bias voltage to be properly operated in pulse-echo imaging applications. The typical bias supply residual ripple of high-quality high-voltage (HV) generators is in the millivolt range, which is comparable with the amplitude of the received echo signals, and it is particularly difficult to minimize. The aim of this paper is to analyze the classical CMUT biasing circuits, highlighting the features of each one, and to propose two novel HV generator architectures optimized for CMUT biasing applications. The first circuit proposed is an ultralow-residual ripple (CMUT by charging a buffer capacitor synchronously with the pulsing sequence, thus reducing the impact of the switching noise on the received echo signals. The small area of the circuit (about 1.5 cm 2 ) makes it possible to generate the bias voltage inside the probe, very close to the CMUT, making the proposed solution attractive for portable applications. Measurements and experiments are shown to demonstrate the effectiveness of the new approaches presented.

  8. Development of a Novel Transparent Flexible Capacitive Micromachined Ultrasonic Transducer.

    Science.gov (United States)

    Pang, Da-Chen; Chang, Cheng-Min

    2017-06-20

    This paper presents the world's first transparent flexible capacitive micromachined ultrasonic transducer (CMUT) that was fabricated through a roll-lamination technique. This polymer-based CMUT has advantages of transparency, flexibility, and non-contacting detection which provide unique functions in display panel applications. Comprising an indium tin oxide-polyethylene terephthalate (ITO-PET) substrate, SU-8 sidewall and vibrating membranes, and silver nanowire transparent electrode, the transducer has visible-light transmittance exceeding 80% and can operate on curved surfaces with a 40 mm radius of curvature. Unlike the traditional silicon-based high temperature process, the CMUT can be fabricated on a flexible substrate at a temperature below 100 °C to reduce residual stress introduced at high temperature. The CMUT on the curved surfaces can detect a flat target and finger at distances up to 50 mm and 40 mm, respectively. The transparent flexible CMUT provides a better human-machine interface than existing touch panels because it can be integrated with a display panel for non-contacting control in a health conscious environment and the flexible feature is critical for curved display and wearable electronics.

  9. Development of a Novel Transparent Flexible Capacitive Micromachined Ultrasonic Transducer

    Directory of Open Access Journals (Sweden)

    Da-Chen Pang

    2017-06-01

    Full Text Available This paper presents the world’s first transparent flexible capacitive micromachined ultrasonic transducer (CMUT that was fabricated through a roll-lamination technique. This polymer-based CMUT has advantages of transparency, flexibility, and non-contacting detection which provide unique functions in display panel applications. Comprising an indium tin oxide-polyethylene terephthalate (ITO-PET substrate, SU-8 sidewall and vibrating membranes, and silver nanowire transparent electrode, the transducer has visible-light transmittance exceeding 80% and can operate on curved surfaces with a 40 mm radius of curvature. Unlike the traditional silicon-based high temperature process, the CMUT can be fabricated on a flexible substrate at a temperature below 100 °C to reduce residual stress introduced at high temperature. The CMUT on the curved surfaces can detect a flat target and finger at distances up to 50 mm and 40 mm, respectively. The transparent flexible CMUT provides a better human-machine interface than existing touch panels because it can be integrated with a display panel for non-contacting control in a health conscious environment and the flexible feature is critical for curved display and wearable electronics.

  10. Mass-spring matching layers for high-frequency ultrasound transducers: a new technique using vacuum deposition.

    Science.gov (United States)

    Brown, Jeremy; Sharma, Srikanta; Leadbetter, Jeff; Cochran, Sandy; Adamson, Rob

    2014-11-01

    We have developed a technique of applying multiple matching layers to high-frequency (>30 MHz) imaging transducers, by using carefully controlled vacuum deposition alone. This technique uses a thin mass-spring matching layer approach that was previously described in a low-frequency (1 to 10 MHz) transducer design with epoxied layers. This mass- spring approach is more suitable to vacuum deposition in highfrequency transducers over the conventional quarter-wavelength resonant cavity approach, because thinner layers and more versatile material selection can be used, the difficulty in precisely lapping quarter-wavelength matching layers is avoided, the layers are less attenuating, and the layers can be applied to a curved surface. Two different 3-mm-diameter 45-MHz planar lithium niobate transducers and one geometrically curved 3-mm lithium niobate transducer were designed and fabricated using this matching layer approach with copper as the mass layer and parylene as the spring layer. The first planar lithium niobate transducer used a single mass-spring matching network, and the second planar lithium niobate transducer used a single mass-spring network to approximate the first layer in a dual quarter-wavelength matching layer system in addition to a conventional quarter-wavelength layer as the second matching layer. The curved lithium niobate transducer was press focused and used a similar mass-spring plus quarter-wavelength matching layer network. These transducers were then compared with identical transducers with no matching layers and the performance improvement was quantified. The bandwidth of the lithium niobate transducer with the single mass-spring layer was measured to be 46% and the insertion loss was measured to be -21.9 dB. The bandwidth and insertion loss of the lithium niobate transducer with the mass-spring network plus quarter-wavelength matching were measured to be 59% and -18.2 dB, respectively. These values were compared with the unmatched

  11. Design and Stress Analysis of Low-Noise Adjusted Bearing Contact Spiral Bevel Gears

    Science.gov (United States)

    Fuentes, A.; Litvin, F. L.; Mullins, B. R.; Woods, R.; Handschuh, R. F.; Lewicki, David G.

    2002-01-01

    An integrated computerized approach for design and stress analysis of low-noise spiral bevel gear drives with adjusted bearing contact is proposed. The procedure of computations is an iterative process that requires four separate procedures and provide: (a) a parabolic function of transmission errors that is able to reduce the effect of errors of alignment on noise and vibration, and (b) reduction of the shift of bearing contact caused by misalignment. Application of finite element analysis enables us to determine the contact and bending stresses and investigate the formation of the bearing contact. The design of finite element models and boundary conditions is automated and does not require intermediate CAD computer programs for application of general purpose computer program for finite element analysis.

  12. Lamb and SH wave transducer arrays for the inspection of large areas of thick plates

    Science.gov (United States)

    Wilcox, P.; Lowe, M.; Cawley, P.

    2000-05-01

    The motivation for this work is to develop a rapid inspection system for large steel plates, such as those which the floors and walls of oil storage tanks are constructed from. One approach to inspecting plates using guided ultrasonic waves, is to design a transduction system which uses monolithic devices such as wedge transducers, inter-digital transducers or meander coil electro-magnetic acoustic transducers (EMATs). Unfortunately, in order to achieve a given level of performance at a particular operating point on the dispersion curves, the physical dimensions of a monolithic transducer must be scaled in proportion to the thickness of plate under inspection. This renders the use of monolithic devices on thicker plates increasingly impractical for several reasons, not least because of the cost and difficulties involved in manufacturing large devices. Also, particular monolithic devices are limited to a small range of applications since they are generally designed to be sensitive to a particular wavelength and to be either unfocused or have a fixed focal length. A more attractive solution is to use an array device containing a number of elements which behave individually as point transducers. By controlling the elements individually, wavelength selection, beam steering and focusing can all be performed by post processing the same set of test data. Encouraging experimental results obtained using this technique will be shown for several array designs which operate on 5-10 mm thick plates.

  13. Modal analysis and nonlinear characterization of an airborne power ultrasonic transducer with rectangular plate radiator.

    Science.gov (United States)

    Andrés, R R; Acosta, V M; Lucas, M; Riera, E

    2018-01-01

    Some industrial processes like particle agglomeration or food dehydration among others can be enhanced by the use of power ultrasonic technologies. These technologies are based on an airborne power ultrasonic transducer (APUT) constituted by a pre-stressed Langevin-type transducer, a mechanical amplifier and an extensive plate radiator. In order to produce the desired effects in industrial processing, the transducer has to vibrate in an extensional mode driving an extensive radiator in the desired flexural mode with high amplitude displacements. Due to the generation of these high amplitude displacements in the radiator surfaces, non-linear effects like frequency shifts, hysteresis or modal interactions, among others, may be produced in the transducer behavior. When any nonlinear effect appears, when applying power, the stability and efficiency of this ultrasonic technology decreases, and the transducer may be damaged depending on the excitation power level and the nature of the nonlinearity. In this paper, an APUT with flat rectangular radiator is presented, as the active part of an innovative system with stepped reflectors. The nonlinear behavior of the APUT has been characterized numerically and experimentally in case of the modal analysis and experimentally in the case of dynamic analysis. According to the results obtained after the experiments, no modal interactions are expected, nor do other nonlinear effects. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. New type pressure transducer for severe thermal environments

    Science.gov (United States)

    1969-01-01

    Pressure transducer used in a rocket motor chamber to measure the amplitudes and frequencies of dynamic pressures /exceeding 2000 psi/ occurring during unstable combustion. the transducer utilizes a transpirational cooled porous beryllium plug and pressure transmitting column.

  15. Encapsulation of Capacitive Micromachined Ultrasonic Transducers Using Viscoelastic Polymer

    Science.gov (United States)

    Lin, Der-Song; Zhuang, Xuefeng; Wong, Serena H.; Kupnik, Mario; Khuri-Yakub, Butrus Thomas

    2010-01-01

    The packaging of a medical imaging or therapeutic ultrasound transducer should provide protective insulation while maintaining high performance. For a capacitive micromachined ultrasonic transducer (CMUT), an ideal encapsulation coating would therefore require a limited and predictable change on the static operation point and the dynamic performance, while insulating the high dc and dc actuation voltages from the environment. To fulfill these requirements, viscoelastic materials, such as polydimethylsiloxane (PDMS), were investigated for an encapsulation material. In addition, PDMS, with a glass-transition temperature below room temperature, provides a low Young's modulus that preserves the static behavior; at higher frequencies for ultrasonic operation, this material becomes stiffer and acoustically matches to water. In this paper, we demonstrate the modeling and implementation of the viscoelastic polymer as the encapsulation material. We introduce a finite element model (FEM) that addresses viscoelasticity. This enables us to correctly calculate both the static operation point and the dynamic behavior of the CMUT. CMUTs designed for medical imaging and therapeutic ultrasound were fabricated and encapsulated. Static and dynamic measurements were used to verify the FEM and show excellent agreement. This paper will help in the design process for optimizing the static and the dynamic behavior of viscoelastic-polymer-coated CMUTs. PMID:21170294

  16. Post-Cam Design and Contact Stress on Tibial Posts in Posterior-Stabilized Total Knee Prostheses: Comparison Between a Rounded and a Squared Design.

    Science.gov (United States)

    Watanabe, Toshifumi; Koga, Hideyuki; Horie, Masafumi; Katagiri, Hiroki; Sekiya, Ichiro; Muneta, Takeshi

    2017-12-01

    The post-cam mechanism in posterior stabilized (PS) prostheses plays an important role in total knee arthroplasty (TKA). The purpose of this study is to clarify the difference of the contact stress on the tibial post between a rounded post-cam design and a squared design during deep knee flexion and at hyperextension using the three-dimensional (3D) finite element models. We created 2 types of 3D, finite element models of PS prostheses (types A and B), whose surfaces were identical except for the post-cam geometries: type A has a rounded post-cam design, while type B has a squared design. Both types have a similar curved-shape intercondylar notch of the femoral component. Stress distributions, peak contact stresses, and contact areas on the tibial posts at 90°, 120°, and 150° flexion with/without 10° tibial internal rotation and at 10° hyperextension were compared between the 2 models. Type B demonstrated more concentrated stress distribution compared to type A. The peak contact stresses were similar in both groups during neutral flexion; however, the stresses were much higher in type B during flexion with 10° rotation and at hyperextension. The higher peak contact stresses corresponded to the smaller contact areas in the tibial post. A rounded post-cam design demonstrated less stress concentration during flexion with rotation and at hyperextension compared with a squared design. The results would be useful for development of implant designs and prediction of the contact stress on the tibial post in PS total knee arthroplasty. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Performance comparison of 2-1-3, 1-3 and 1-3-2 piezoelectric composite transducers by finite element method

    Directory of Open Access Journals (Sweden)

    Y. Sun

    2018-03-01

    Full Text Available 1-3 type, 1-3-2 type and 2-1-3 type piezoelectric composites are three proper smart materials for the design and manufacture of ultrasonic transducers. They have been proposed in different stages but possess similar properties. Compared with the initial 1-3 type composite, 1-3-2 composite is of higher mechanical stability. Compared with 1-3-2 composite, 2-1-3 composite has lower manufacturing difficulty. In this paper, a comparative study on these three composites in terms of receiving transducer material properties is presented. Finite element method (FEM has been adopted to calculate longitudinal velocity, thickness electromechanical coupling coefficient and voltage receiving sensitivity. It is concluded that for a large aspect ratio α=1, the performance of 2-1-3 composite transducer is much better than that of 1-3 and 1-3-2 composite transducers. The thickness electromechanical coupling coefficient of 2-1-3 composite transducer is about 5.58 times that of 1-3 composite transducer and 7.42 times that of 1-3-2 composite transducer. The voltage receiving sensitivity at 2 kHz of 2-1-3 composite transducer is 13.1 dB higher than that of 1-3-2 composite transducer and 12.3 dB higher than that of 1-3 composite transducer.

  18. Vibration characteristics of an ultrasonic transducer composed of inner and outer discs

    Science.gov (United States)

    Piao, Chunguang; Kim, Jin O.

    2017-04-01

    This paper considers an ultrasonic transducer composed of piezoelectric solid and hollow discs. The inner solid disc is a transmitter and the outer hollow disc is a receiver of ultrasound. The purpose of this work is to design a disc-shape transducer with separate transmitter and receiver which are operated at a same frequency and have a same center location. The vibration characteristics of the radial and axial motions in the axisymmetric modes were investigated theoretically and experimentally. Theoretically, the differential equations of piezoelectric motions were derived in terms of mechanical displacements and electric potential, and they were solved to produce characteristic equations providing natural frequencies and mode shapes. The theoretical analysis was complimented by the finite-element analysis, which provided three-dimensional mode shapes. Experimentally, the natural frequencies and the radial in-plane motion were measured using an impedance analyzer and an in-plane laser interferometer, respectively. The results of the theoretical analysis were compared with those of experiments, and the theoretical analysis was verified on the basis of this comparison. It appeared that the fundamental frequency of the transducer was similar to but slightly different from that of a single disc transducer of same size. It was found that the transducer composed of inner solid and outer hollow piezoelectric discs could be designed by selecting suitable diameters of each disc.

  19. Dorsal spinal cord stimulation obtunds the capacity of intrathoracic extracardiac neurons to transduce myocardial ischemia.

    Science.gov (United States)

    Ardell, Jeffrey L; Cardinal, René; Vermeulen, Michel; Armour, J Andrew

    2009-08-01

    Populations of intrathoracic extracardiac neurons transduce myocardial ischemia, thereby contributing to sympathetic control of regional cardiac indices during such pathology. Our objective was to determine whether electrical neuromodulation using spinal cord stimulation (SCS) modulates such local reflex control. In 10 anesthetized canines, middle cervical ganglion neurons were identified that transduce the ventricular milieu. Their capacity to transduce a global (rapid ventricular pacing) vs. regional (transient regional ischemia) ventricular stress was tested before and during SCS (50 Hz, 0.2 ms duration at 90% MT) applied to the dorsal aspect of the T1 to T4 spinal cord. Rapid ventricular pacing and transient myocardial ischemia both activated cardiac-related middle cervical ganglion neurons. SCS obtunded their capacity to reflexly respond to the regional ventricular ischemia, but not rapid ventricular pacing. In conclusion, spinal cord inputs to the intrathoracic extracardiac nervous system obtund the latter's capacity to transduce regional ventricular ischemia, but not global cardiac stress. Given the substantial body of literature indicating the adverse consequences of excessive adrenergic neuronal excitation on cardiac function, these data delineate the intrathoracic extracardiac nervous system as a potential target for neuromodulation therapy in minimizing such effects.

  20. Design and analysis of a toroidal tester for the measurement of core losses under axial compressive stress

    Energy Technology Data Exchange (ETDEWEB)

    Alatawneh, Natheer, E-mail: natheer80@yahoo.com [Department of Mining and Materials Engineering, McGill University, QC H3A 0G4 (Canada); Rahman, Tanvir; Lowther, David A. [Department of Electrical and Computer Engineering, McGill University, QC H3A 0E9 (Canada); Chromik, Richard [Department of Mining and Materials Engineering, McGill University, QC H3A 0G4 (Canada)

    2017-06-15

    Highlights: • Develop a toroidal tester for magnetic measurements under compressive axial stress. • The shape of the toroidal ring has been verified using 3D stress analysis. • The developed design has been prototyped, and measurements were carried out. • Physical explanations for the core loss trend due to stress are provided. - Abstract: Electric machine cores are subjected to mechanical stresses due to manufacturing processes. These stresses include radial, circumferential and axial components that may have significant influences on the magnetic properties of the electrical steel and hence, on the output and efficiencies of electrical machines. Previously, most studies of iron losses due to mechanical stress have considered only radial and circumferential components. In this work, an improved toroidal tester has been designed and developed to measure the core losses and the magnetic properties of electrical steel under a compressive axial stress. The shape of the toroidal ring has been verified using 3D stress analysis. Also, 3D electromagnetic simulations show a uniform flux density distribution in the specimen with a variation of 0.03 T and a maximum average induction level of 1.5 T. The developed design has been prototyped, and measurements were carried out using a steel sample of grade 35WW300. Measurements show that applying small mechanical stresses normal to the sample thickness rises the delivered core losses, then the losses decrease continuously as the stress increases. However, the drop in core losses at high stresses does not go lower than the free-stress condition. Physical explanations for the observed trend of core losses as a function of stress are provided based on core loss separation to the hysteresis and eddy current loss components. The experimental results show that the effect of axial compressive stress on magnetic properties of electrical steel at high level of inductions becomes less pronounced.

  1. Can architectural design alter the physiological reaction to psychosocial stress? A virtual TSST experiment.

    Science.gov (United States)

    Fich, Lars Brorson; Jönsson, Peter; Kirkegaard, Poul Henning; Wallergård, Mattias; Garde, Anne Helene; Hansen, Åse

    2014-08-01

    Is has long been established, that views to natural scenes can a have a dampening effect on physiological stress responses. However, as people in Europe, Canada and North America today spent 50-85% of their time indoors, attention might also be paid to how the artificial man-made indoor environment influences these mechanisms. The question that this study attempts to start addressing is therefore whether certain design, characteristics of indoor spaces can make a difference to the physiological stress response as well. Using a virtual version of the Trier Social Stress Test, in which the space is computer generated and properties of the space therefore can be systematically varied, we measured saliva cortisol and heart rate variability in participants in a closed room versus a room with openings. As shown by a significant linear contrast interaction between groups and TSST conditions, participants in the closed room responded with more pronounced cortisol reactivity to stress induction, and continued to show higher levels throughout recovery, compared to participants in the open room. No differences were found regarding any part of the autonomic nervous system. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Detection of Interfacial Debonding in a Rubber-Steel-Layered Structure Using Active Sensing Enabled by Embedded Piezoceramic Transducers.

    Science.gov (United States)

    Feng, Qian; Kong, Qingzhao; Jiang, Jian; Liang, Yabin; Song, Gangbing

    2017-09-01

    Rubber-steel-layered structures are used in many engineering applications. Laminated rubber-steel bearing, as a type of seismic isolation device, is one of the most important applications of the rubber-steel-layered structures. Interfacial debonding in rubber-steel-layered structures is a typical failure mode, which can severely reduce their load-bearing capacity. In this paper, the authors developed a simple but effective active sensing approach using embedded piezoceramic transducers to provide an in-situ detection of the interfacial debonding between the rubber layers and steel plates. A sandwiched rubber-steel-layered specimen, consisting of one rubber layer and two steel plates, was fabricated as the test specimen. A novel installation technique, which allows the piezoceramic transducers to be fully embedded into the steel plates without changing the geometry and the surface conditions of the plates, was also developed in this research. The active sensing approach, in which designed stress waves can propagate between a pair of the embedded piezoceramic transducers (one as an actuator and the other one as a sensor), was employed to detect the steel-rubber debonding. When the rubber-steel debonding occurs, the debonded interfaces will attenuate the propagating stress wave, so that the amplitude of the received signal will decrease. The rubber-steel debonding was generated by pulling the two steel plates in opposite directions in a material-testing machine. The changes of the received signal before and after the debonding were characterized in a time domain and further quantified by using a wavelet packet-based energy index. Experiments on the healthy rubber-steel-layered specimen reveal that the piezoceramic-induced stress wave can propagate through the rubber layer. The destructive test on the specimen demonstrates that the piezoceramic-based active sensing approach can effectively detect the rubber-steel debonding failure in real time. The active sensing

  3. Detection of Interfacial Debonding in a Rubber–Steel-Layered Structure Using Active Sensing Enabled by Embedded Piezoceramic Transducers

    Science.gov (United States)

    Feng, Qian; Jiang, Jian; Liang, Yabin; Song, Gangbing

    2017-01-01

    Rubber–steel-layered structures are used in many engineering applications. Laminated rubber–steel bearing, as a type of seismic isolation device, is one of the most important applications of the rubber–steel-layered structures. Interfacial debonding in rubber–steel-layered structures is a typical failure mode, which can severely reduce their load-bearing capacity. In this paper, the authors developed a simple but effective active sensing approach using embedded piezoceramic transducers to provide an in-situ detection of the interfacial debonding between the rubber layers and steel plates. A sandwiched rubber–steel-layered specimen, consisting of one rubber layer and two steel plates, was fabricated as the test specimen. A novel installation technique, which allows the piezoceramic transducers to be fully embedded into the steel plates without changing the geometry and the surface conditions of the plates, was also developed in this research. The active sensing approach, in which designed stress waves can propagate between a pair of the embedded piezoceramic transducers (one as an actuator and the other one as a sensor), was employed to detect the steel–rubber debonding. When the rubber–steel debonding occurs, the debonded interfaces will attenuate the propagating stress wave, so that the amplitude of the received signal will decrease. The rubber–steel debonding was generated by pulling the two steel plates in opposite directions in a material-testing machine. The changes of the received signal before and after the debonding were characterized in a time domain and further quantified by using a wavelet packet-based energy index. Experiments on the healthy rubber–steel-layered specimen reveal that the piezoceramic-induced stress wave can propagate through the rubber layer. The destructive test on the specimen demonstrates that the piezoceramic-based active sensing approach can effectively detect the rubber–steel debonding failure in real time. The

  4. Stress distributions in maxillary central incisors restored with various types of post materials and designs.

    Science.gov (United States)

    Madfa, A A; Kadir, M R Abdul; Kashani, J; Saidin, S; Sulaiman, E; Marhazlinda, J; Rahbari, R; Abdullah, B J J; Abdullah, H; Abu Kasim, N H

    2014-07-01

    Different dental post designs and materials affect the stability of restoration of a tooth. This study aimed to analyse and compare the stability of two shapes of dental posts (parallel-sided and tapered) made of five different materials (titanium, zirconia, carbon fibre and glass fibre) by investigating their stress transfer through the finite element (FE) method. Ten three-dimensional (3D) FE models of a maxillary central incisor restored with two different designs and five different materials were constructed. An oblique loading of 100 N was applied to each 3D model. Analyses along the centre of the post, the crown-cement/core and the post-cement/dentine interfaces were computed, and the means were calculated. One-way ANOVAs followed by post hoc tests were used to evaluate the effectiveness of the post materials and designs (p=0.05). For post designs, the tapered posts introduced significantly higher stress compared with the parallel-sided post (pstress was found for stainless steel, followed by zirconia, titanium, glass fibre and carbon fibre posts (pstress distribution at the middle and apical part of the posts compared with the stainless steel, zirconia and titanium posts. The opposite results were observed at the crown-cement/core interface. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  5. Magnetoelastic Transducer Materials - a Plateable Possibility

    DEFF Research Database (Denmark)

    Jensen, Jens Dahl; Møller, Per

    2001-01-01

    A short presentation of the magnetostriction theory as well as a series of possible applications for magnetoelastic transducers are given. A review of the present state of development for these materials is discussed with relation to the various ways of manufacture. The paper is concluded with th...... as the reference material Terfenol-D were obtained, but reproduction of exact magnetic properties is still critical with the new plating technique.......A short presentation of the magnetostriction theory as well as a series of possible applications for magnetoelastic transducers are given. A review of the present state of development for these materials is discussed with relation to the various ways of manufacture. The paper is concluded...... with the presentation of a method for making magnetoelastic materials by electrochemical deposition (electroless) as tried by the authors in collaboration with the Daimler-Chrysler research centre in Ulm, Germany. First results of this work are both promising and intriguing: Sensitivities of the same order...

  6. Acousto-optical Transducer with Surface Plasmons

    Science.gov (United States)

    Kolomenskii, A. A.; Surovic, E.; Schuessler, H. A.

    2018-04-01

    The surface plasmon resonance (SPR) is a sensitive technique for the detection of changes in dielectric parameters in close proximity to a metal film supporting surface plasmon waves. Here we study the application of the SPR effect to an efficient conversion of an acoustic signal into an optical one. Such a transducer potentially has a large bandwidth and good sensitivity. When an acoustic wave is incident onto a receiving plate positioned within the penetration depth of the surface plasmons, it creates displacements of the surface of the plate and, thus, modulates the dielectric properties in the proximity of the gold film. This modulation, in turn, modifies the light reflection under surface plasmon resonance conditions. We simulate characteristics of this acousto-optical transducer with surface plasmons and provide sets of parameters at the optical wavelength of 800 nm and 633 nm for its realization.

  7. Dissipation in vibrating superleak second sound transducers

    International Nuclear Information System (INIS)

    Giordano, N.

    1985-01-01

    We have performed an experimental study of the generation and detection of second sound in 4 He using vibrating superleak second sound transducers. At temperatures well below T/sub lambda/ and for low driving amplitudes, the magnitude of the generated second sound wave is proportional to the drive amplitude. However, near T/sub lambda/ and for high drive amplitudes this is no longer the case--instead, the second sound amplitude saturates. In this regime we also find that overtones of the drive frequency are generated. Our results suggest that this behavior is due to critical velocity effects in the pores of the superleak in the generator transducer. This type of measurement may prove to be a useful way in which to study critical velocity effects in confined geometries

  8. Design optimization of scaffold microstructures using wall shear stress criterion towards regulated flow-induced erosion.

    Science.gov (United States)

    Chen, Yuhang; Schellekens, Michiel; Zhou, Shiwei; Cadman, Joseph; Li, Wei; Appleyard, Richard; Li, Qing

    2011-08-01

    Tissue scaffolds aim to provide a cell-friendly biomechanical environment for facilitating cell growth. Existing studies have shown significant demands for generating a certain level of wall shear stress (WSS) on scaffold microstructural surfaces for promoting cellular response and attachment efficacy. Recently, its role in shear-induced erosion of polymer scaffold has also drawn increasing attention. This paper proposes a bi-directional evolutionary structural optimization (BESO) approach for design of scaffold microstructure in terms of the WSS uniformity criterion, by downgrading highly-stressed solid elements into fluidic elements and/or upgrading lowly-stressed fluidic elements into solid elements. In addition to this, a computational model is presented to simulate shear-induced erosion process. The effective stiffness and permeability of initial and optimized scaffold microstructures are characterized by the finite element based homogenization technique to quantify the variations of mechanical properties of scaffold during erosion. The illustrative examples show that a uniform WSS is achieved within the optimized scaffold microstructures, and their architectural and biomechanical features are maintained for a longer lifetime during shear-induced erosion process. This study provides a mathematical means to the design optimization of cellular biomaterials in terms of the WSS criterion towards controllable shear-induced erosion.

  9. Passive Mode Carbon Nanotube Underwater Acoustic Transducer

    Science.gov (United States)

    2016-09-20

    irreversible Joule heat) by an electric light bulb . The reciprocal (or reverse) of this process by supplying heat and shining light to the same electric bulb ...limit the invention to the precise form disclosed; and obviously many modifications and variations are possible in light of the above teaching...300151 1 of 14 PASSIVE MODE CARBON NANOTUBE UNDERWATER ACOUSTIC TRANSDUCER STATEMENT OF GOVERNMENT INTEREST [0001] The invention described

  10. Effect of Jig Design and Assessment of Stress Distribution in Testing Metal-Ceramic Adhesion.

    Science.gov (United States)

    Özcan, Mutlu; Kojima, Alberto Noriyuki; Nishioka, Renato Sussumu; Mesquita, Alfredo Mikail Melo; Bottino, Marco Antonio; Filho, Gilberto Duarte

    2016-12-01

    In testing adhesion using shear bond test, a combination of shear and tensile forces occur at the interface, resulting in complex stresses. The jig designs used for this kind of test show variations in published studies, complicating direct comparison between studies. This study evaluated the effect of different jig designs on metal-ceramic bond strength and assessed the stress distribution at the interface using finite element analysis (FEA). Metal-ceramic (Metal: Ni-Cr, Wiron 99, Bego; Ceramic: Vita Omega 900, Vita) specimens (N = 36) (diameter: 4 mm, veneer thickness: 4 mm; base diameter: 5 mm, thickness: 1 mm) were fabricated and randomly divided into three groups (n = 12 per group) to be tested using one of the following jig designs: (a) chisel (CH) (ISO 11405), (b) steel strip (SS), (c) piston (PI). Metal-ceramic interfaces were loaded under shear until debonding in a universal testing machine (0.5 mm/min). Failure types were evaluated using scanning electron microscopy (SEM). FEA was used to study the stress distribution using different jigs. Metal-ceramic bond strength data (MPa) were analyzed using ANOVA and Tukey's tests (α = 0.05). The jig type significantly affected the bond results (p = 0.0001). PI type of jig presented the highest results (MPa) (p Metal-ceramic bond strength was affected by the jig design. Accordingly, the results of in vitro studies on metal-ceramic adhesion should be evaluated with caution. When adhesion of ceramic materials to metals is evaluated in in vitro studies, it should be noted that the loading jig type affects the results. Clinical observations should report on the location and type of ceramic fractures in metal-ceramic reconstructions so that the most relevant test method can be identified. © 2015 by the American College of Prosthodontists.

  11. Static Metrological Characterization of a Ferrimagnetic Resonance Transducer for Real-Time Magnetic Field Markers in Particle Accelerators

    CERN Document Server

    Arpaia, P; Caspers, F; Golluccio, G; Petrone, C

    2011-01-01

    The metrological characterization of a magnetic field transducer based on ferrimagnetic resonance for real-time markers in particle accelerators is reported. The transducer is designed to measure the magnetic field with an uncertainty of ± 10-5 T. A case study on the new real-time field monitoring system for the CERN accelerators highlighting the performance improvement achieved through the new ferrimagnetic transducer is described. Preliminary experimental results of the characterization for static and dynamic fields are discussed.

  12. Performance and stress analysis of oxide thermoelectric module architecture designed for maximum power output

    DEFF Research Database (Denmark)

    Wijesekara, Waruna; Rosendahl, Lasse; Wu, NingYu

    Oxide thermoelectric materials are promising candidates for energy harvesting from mid to high temperature heat sources. In this work, the oxide thermoelectric materials and the final design of the high temperature thermoelectric module were developed. Also, prototypes of oxide thermoelectric gen...... and simulation results were validated. In addition, the thermal stress and the thermal expansion of the thermoelectric uni-couple were studied in this work....... generator were built for high temperature applications. This paper specifically discusses the thermoelectric module design and the prototype validations of the design. Here p type calcium cobalt oxide and n type aluminum doped ZnO were developed as the oxide thermoelectric materials. Hot side and cold side...

  13. Electric Stress Computations for Designing a Novel Unibody Composite Cross-Arm Using Finite Element Method

    DEFF Research Database (Denmark)

    Jahangiri, Tohid; Wang, Qian; Bak, Claus Leth

    2017-01-01

    This paper deal with the electrical performance of a newly proposed fully composite pylon in Denmark, which has a unibody composite cross-arm at 420 kV highest system voltage level. Electric field consideration along the insulations of the novel unibody cross-arm is one of the most important...... requirements in the design process of a nontraditional pylon. In this paper, ANSYS finite element software is used to calculate the electric field and potential distribution around and inside the fully composite pylon. Electric field criteria related to the design of composite cross-arms are reviewed...... and applied for interpreting the electrical performance of the unibody cross-arm at power frequency stresses. Three different designs of non-conductive conductor clamp are assumed for the attachment points between phase conductors and the unibody crossarm. The side effects of conductor clamp are included in 2...

  14. design and Application of Neutron Residual Stress Diffractometer for China Advanced Research Reactor

    International Nuclear Information System (INIS)

    Li Junhong; Gao Jianbo; Li Jizhou; Han Songbai; Zu Yong; Liu Rongdeng; Liu Xiaolong; Liu Yuntao; Chen dongfeng

    2010-01-01

    The neutron residual stress diffractometer for China Advanced Research Reactor (CARR) is the first instrument in China for the residual stress measurement using neutron diffraction method. Its sample table and some affiliated equipment were relocated from Sweden. According to the situation of CARR, the conceptional and physical design and mechanism fabrication were finished. Now the whole instrument is going to be put in commissioning. The take-off angle of new monochromator's shielding could be continuously changeable from 41 degree to 109 degree. The position of monochromator could be adjusted conveniently and flexibly by a five axis table. The resolution of this diffractometer could reach 0.2% using the double focusing Si(311) monochromator. The technical specification of one dimension neutron position sensitive detector ORDELA 1128N is better than that of ORDELA 1150N used on REST. The various affiliated equipment of instrument enable the diffractometer to measure the texture and tensional experiment in situ. (authors)

  15. Impact of shear stress and impeller design on the production of biogas in anaerobic digesters.

    Science.gov (United States)

    Lebranchu, Aline; Delaunay, Stéphane; Marchal, Philippe; Blanchard, Fabrice; Pacaud, Stéphane; Fick, Michel; Olmos, Eric

    2017-12-01

    Today, intensification of anaerobic digestion is still a scientific and technical challenge. The present study proposed combined experimental and computational fluid dynamics simulations to characterize the impact of shear stress and impeller design on the biogas production after sequential additions of substrate. Liquid phase (cattle manure digestate) rheological law was experimentally determined and input in numerical simulations. The results showed that the original use of a double helical ribbon in digester allowed a significantly faster dispersion of fresh substrate than the use of a classical Rushton turbine, leading to a 50% higher methane production rate. However, with both impellers, too high agitation rates entailed a clear slow-down of production rate and a decrease in CH 4 content. To avoid this loss of productivity, it was shown that the maximal value of shear stress, determined by numerical simulations, was a consistent parameter to set the upper agitation conditions in digesters. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Investigation on Stress-Rupture Behavior of a Chopped-Glass-Fiber Composite for Automotive Durability Design Criteria

    Energy Technology Data Exchange (ETDEWEB)

    Ren, W

    2001-08-24

    Practical and inexpensive testing methods were developed to investigate stress-rupture properties of a polymeric composite with chopped glass fiber reinforcement for automotive applications. The material was tested in representative automotive environments to generate experimental data. The results indicate that environments have substantial effects on the stress-rupture behavior. The data were analyzed and developed into stress-rupture design criteria to address one of the durability aspects of the material for automotive structural applications.

  17. The influence of personality traits and social support on male nursing student life stress: a cross-sectional research design.

    Science.gov (United States)

    Lou, Jiunn-Horng; Chen, Sheng-Hwang; Yu, Hsing-Yi; Li, Ren-Hau; Yang, Cheng-I; Eng, Cheng-Joo

    2010-06-01

    Understanding how male nursing students alleviate life stress during their academic career is conducive to their development as successful nursing professionals. This study was designed to understand the personality traits, social support, and life stresses of male nursing students. The respective influences of personality traits and social support on life stress were also explored. The study used a cross-sectional research design. A college in central Taiwan was targeted as the site for data collection. A total of 158 questionnaires were dispatched, with 145 valid copies returned (valid response rate = 91.7%). Structured questionnaires were designed to collect data on participant demographics, personality traits, social support, and life stress. Statistical methods such as descriptive statistics, one-way analysis of variance, and multiple regression analysis were applied to data analysis. Major findings of this study revealed that (a) in general, the personality traits, social support, and life stress of male nursing students scored in the medium to high range. Participants reported encountering more stress from learning and life goals than from interpersonal stress. (b) Male nursing student demographic variables (e.g., parent [father and mother considered separately] education level) and the personality traits of conscientiousness and family support, respectively, were found to impact significantly on participant life stress perceptions. And (c) the only significant predictors of life stress were support from family and education level of participant fathers and mothers, accounting for about 23.7% of variability. It is suggested that nursing students in each year of their academic career should be exposed to courses geared to reduce the life stress perceptions (especially in the areas of learning and career development) of male nursing students. Increased family support is an effective way to decrease male nursing student life stress. This study could be a

  18. Investigation on Stress-Rupture Behavior of a Chopped-Glass-Fiber Composite for Automotive Durability Design Criteria; FINAL

    International Nuclear Information System (INIS)

    Ren, W

    2001-01-01

    Practical and inexpensive testing methods were developed to investigate stress-rupture properties of a polymeric composite with chopped glass fiber reinforcement for automotive applications. The material was tested in representative automotive environments to generate experimental data. The results indicate that environments have substantial effects on the stress-rupture behavior. The data were analyzed and developed into stress-rupture design criteria to address one of the durability aspects of the material for automotive structural applications

  19. Language of Transducer Manipulation: Codifying Terms for Effective Teaching.

    Science.gov (United States)

    Bahner, David P; Blickendorf, J Matthew; Bockbrader, Marcia; Adkins, Eric; Vira, Amar; Boulger, Creagh; Panchal, Ashish R

    2016-01-01

    There is a need for consistent, repetitive, and reliable terminology to describe the basic manipulations of the ultrasound transducer. Previously, 5 basic transducer motions have been defined and used in education. However, even with this effort, there is still a lack of consistency and clarity in describing transducer manipulation and motion. In this technical innovation, we describe an expanded definition of transducer motions, which include movements to change the transducer's angle of insonation to the target as well as the location on the body to optimize the ultrasound image. This new terminology may allow for consistent teaching and improved communication in the process of image acquisition.

  20. A Mathematical Model of a Novel 3D Fractal-Inspired Piezoelectric Ultrasonic Transducer.

    Science.gov (United States)

    Canning, Sara; Walker, Alan J; Roach, Paul A

    2016-12-17

    Piezoelectric ultrasonic transducers have the potential to operate as both a sensor and as an actuator of ultrasonic waves. Currently, manufactured transducers operate effectively over narrow bandwidths as a result of their regular structures which incorporate a single length scale. To increase the operational bandwidth of these devices, consideration has been given in the literature to the implementation of designs which contain a range of length scales. In this paper, a mathematical model of a novel Sierpinski tetrix fractal-inspired transducer for sensor applications is presented. To accompany the growing body of research based on fractal-inspired transducers, this paper offers the first sensor design based on a three-dimensional fractal. The three-dimensional model reduces to an effective one-dimensional model by allowing for a number of assumptions of the propagating wave in the fractal lattice. The reception sensitivity of the sensor is investigated. Comparisons of reception force response (RFR) are performed between this novel design along with a previously investigated Sierpinski gasket-inspired device and standard Euclidean design. The results indicate that the proposed device surpasses traditional design sensors.

  1. A Mathematical Model of a Novel 3D Fractal-Inspired Piezoelectric Ultrasonic Transducer

    Science.gov (United States)

    Canning, Sara; Walker, Alan J.; Roach, Paul A.

    2016-01-01

    Piezoelectric ultrasonic transducers have the potential to operate as both a sensor and as an actuator of ultrasonic waves. Currently, manufactured transducers operate effectively over narrow bandwidths as a result of their regular structures which incorporate a single length scale. To increase the operational bandwidth of these devices, consideration has been given in the literature to the implementation of designs which contain a range of length scales. In this paper, a mathematical model of a novel Sierpinski tetrix fractal-inspired transducer for sensor applications is presented. To accompany the growing body of research based on fractal-inspired transducers, this paper offers the first sensor design based on a three-dimensional fractal. The three-dimensional model reduces to an effective one-dimensional model by allowing for a number of assumptions of the propagating wave in the fractal lattice. The reception sensitivity of the sensor is investigated. Comparisons of reception force response (RFR) are performed between this novel design along with a previously investigated Sierpinski gasket-inspired device and standard Euclidean design. The results indicate that the proposed device surpasses traditional design sensors. PMID:27999306

  2. A Mathematical Model of a Novel 3D Fractal-Inspired Piezoelectric Ultrasonic Transducer

    Directory of Open Access Journals (Sweden)

    Sara Canning

    2016-12-01

    Full Text Available Piezoelectric ultrasonic transducers have the potential to operate as both a sensor and as an actuator of ultrasonic waves. Currently, manufactured transducers operate effectively over narrow bandwidths as a result of their regular structures which incorporate a single length scale. To increase the operational bandwidth of these devices, consideration has been given in the literature to the implementation of designs which contain a range of length scales. In this paper, a mathematical model of a novel Sierpinski tetrix fractal-inspired transducer for sensor applications is presented. To accompany the growing body of research based on fractal-inspired transducers, this paper offers the first sensor design based on a three-dimensional fractal. The three-dimensional model reduces to an effective one-dimensional model by allowing for a number of assumptions of the propagating wave in the fractal lattice. The reception sensitivity of the sensor is investigated. Comparisons of reception force response (RFR are performed between this novel design along with a previously investigated Sierpinski gasket-inspired device and standard Euclidean design. The results indicate that the proposed device surpasses traditional design sensors.

  3. Capturing the Active Ingredients of Multicomponent Participatory Organizational Stress Interventions Using an Adapted Study Design.

    Science.gov (United States)

    Biron, Caroline; Ivers, Hans; Brun, Jean-Pierre

    2016-10-01

    Adapted study designs use process evaluation to incorporate a measure of intervention exposure and create an artificial control and intervention groups. Taking into account exposure levels to interventions combines process and outcome evaluation and strengthens the design of the study when exposure levels cannot be controlled. This study includes longitudinal data (two assessments) with added process measures at time 2 gathered from three complex participatory intervention projects in Canada in a hospital and a university. Structural equation modelling was used to explore the specific working mechanisms of particular interventions on stress outcomes. Results showed that higher exposure to interventions aiming to modify tasks and working conditions reduced demands and improved social support, but not job control, which in turn, reduced psychological distress. Exposure to interventions aiming to improve relationships was not related to psychosocial risks. Most studies cannot explain how interventions produce their effects on outcomes, especially when there are multiple concurrent interventions delivered in several contexts. This study advances knowledge on process evaluation by using an adapted study design to capture the active ingredients of multicomponent interventions and suggesting some mechanisms by which the interventions produce their effects on stress outcomes. It provides an illustration of how to conduct process evaluation and relate exposure levels to observed outcomes. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  4. Stress distribution on short implants with different designs: a photoelastic analysis.

    Science.gov (United States)

    Goiato, Marcelo Coelho; de Medeiros, Rodrigo Antonio; Sônego, Mariana Vilela; de Lima, Taynara Maria Toito; Pesqueira, Aldiéris Alves; Dos Santos, Daniela Micheline

    2017-02-01

    Short dental implants have been used as an attempt to avoid bone grafts surgery, however there are few literature reports that evaluate changes to their design. Therefore, the aim of this study was to assess the effect of different short implant design on stress distribution through photoelastic analysis. Six external hexagon (5 × 5 mm) short dental implants with different design were used. Each group was treated with a single crown and a three element fixed partial dental prosthesis, resulting in a total of 12 photoelastic models. The assembling photoelastic model-implant-prosthesis was set in a circular polariscope where loads of 100N were applied on the occlusal surface with a Universal Test Machine (UTM). The tension fringes were photographed and later assessed qualitatively by a graphic software (Adobe Photoshop). Less high-intensity fringes were observed on the short implants with triangular threads, short external hexagon and flat apical profile. In conclusion, the macrodesign influenced the amount of stress distributed to the bone when short dental implants are placed.

  5. Influence of three different implant thread designs on stress distribution: A three-dimensional finite element analysis

    Directory of Open Access Journals (Sweden)

    Mansi Manish Oswal

    2016-01-01

    Full Text Available Purpose: Clinical success of implant prosthodontics is dependent in part upon the type of implant thread design. The selection of implant thread design plays an important role in the outcome of the treatment. This study was undertaken to evaluate the pattern of stress distribution using a finite element analysis; hence, the area which would be bearing maximum load for a given design would be arrived. Materials and Methods: Three implants with different thread designs, namely V-thread, buttress, and reverse buttress thread designs were considered and dimensions were standardized. The site considered was the mandibular molar region with cortical and trabecular bone assuming to be isotropic and homogeneous. The implant modeling was done with the CATIA software. Vertical loads of 100N were applied. The stresses were calculated as Von Mises stress criterion. Results: Maximum stresses were seen at the cortical bone and were transferred to the implant. Minimum Von Mises stresses were seen with reverse buttress thread design at the cortical bone. The stresses were observed least at the cancellous bone and maximum at the implant. Conclusion: Hence, within the limitations of this study the results obtained can be applied clinically for appropriate selection of implant thread design for a predictable success of implant therapy.

  6. Visualization of Time-Series Sensor Data to Inform the Design of Just-In-Time Adaptive Stress Interventions.

    Science.gov (United States)

    Sharmin, Moushumi; Raij, Andrew; Epstien, David; Nahum-Shani, Inbal; Beck, J Gayle; Vhaduri, Sudip; Preston, Kenzie; Kumar, Santosh

    2015-09-01

    We investigate needs, challenges, and opportunities in visualizing time-series sensor data on stress to inform the design of just-in-time adaptive interventions (JITAIs). We identify seven key challenges: massive volume and variety of data, complexity in identifying stressors, scalability of space, multifaceted relationship between stress and time, a need for representation at multiple granularities, interperson variability, and limited understanding of JITAI design requirements due to its novelty. We propose four new visualizations based on one million minutes of sensor data (n=70). We evaluate our visualizations with stress researchers (n=6) to gain first insights into its usability and usefulness in JITAI design. Our results indicate that spatio-temporal visualizations help identify and explain between- and within-person variability in stress patterns and contextual visualizations enable decisions regarding the timing, content, and modality of intervention. Interestingly, a granular representation is considered informative but noise-prone; an abstract representation is the preferred starting point for designing JITAIs.

  7. Sensitivity analysis for improving nanomechanical photonic transducers biosensors

    International Nuclear Information System (INIS)

    Fariña, D; Álvarez, M; Márquez, S; Lechuga, L M; Dominguez, C

    2015-01-01

    The achievement of high sensitivity and highly integrated transducers is one of the main challenges in the development of high-throughput biosensors. The aim of this study is to improve the final sensitivity of an opto-mechanical device to be used as a reliable biosensor. We report the analysis of the mechanical and optical properties of optical waveguide microcantilever transducers, and their dependency on device design and dimensions. The selected layout (geometry) based on two butt-coupled misaligned waveguides displays better sensitivities than an aligned one. With this configuration, we find that an optimal microcantilever thickness range between 150 nm and 400 nm would increase both microcantilever bending during the biorecognition process and increase optical sensitivity to 4.8   ×   10 −2  nm −1 , an order of magnitude higher than other similar opto-mechanical devices. Moreover, the analysis shows that a single mode behaviour of the propagating radiation is required to avoid modal interference that could misinterpret the readout signal. (paper)

  8. Design, simulation and test for double focusing Si monochromator of neutron residual stress diffractometer

    International Nuclear Information System (INIS)

    Hu Rui; Liu Yuntao; Wang Wei; Liu Zhongxiao; Li Junhong; Gao Jianbo; Wang Hongli; Chen Dongfeng

    2015-01-01

    The double focusing Si monochromator was designed, simulated and tested for the neutron residual stress diffractometer on China Advanced Research Reactor. The optimal vertical curvature and the optimal thickness of Si wafers were obtained by SIMRES simulation program. In addition, the figure of merit in dependence on the scattering angle, monochromator horizontal curvature and wavelength was also determined by this program. The neutron beam test results indicate that the intensity of neutron increases by 15 times by using double focusing Si monochromator in comparison with Cu monochromator. (authors)

  9. Design criteria for modified Zeta rectifier with reduced voltage stress and low effect on main

    International Nuclear Information System (INIS)

    Sabzali, Ahmad J.; Ismail, Esam H.; Al-Saffar, Mustafa A.

    2008-01-01

    A single switch low harmonic rectifier based on the Zeta converter, also known as dual of single ended primary inductance converter (dual SEPIC), is presented in this paper. By adding an extra diode in series with both inductors, new discontinuous current modes (DCM) are obtained. By selecting the right DCM, it is possible to design the rectifier such that the voltage on the intermediate dc-link capacitor is less than the output DC voltage. This will result in reduced voltage stress on the main power switch, as well as zero current switching at turn on. The operating principles are confirmed with computer simulation and experimental results

  10. Multiharmonic Frequency-Chirped Transducers for Surface-Acoustic-Wave Optomechanics

    Science.gov (United States)

    Weiß, Matthias; Hörner, Andreas L.; Zallo, Eugenio; Atkinson, Paola; Rastelli, Armando; Schmidt, Oliver G.; Wixforth, Achim; Krenner, Hubert J.

    2018-01-01

    Wide-passband interdigital transducers are employed to establish a stable phase lock between a train of laser pulses emitted by a mode-locked laser and a surface acoustic wave generated electrically by the transducer. The transducer design is based on a multiharmonic split-finger architecture for the excitation of a fundamental surface acoustic wave and a discrete number of its overtones. Simply by introducing a variation of the transducer's periodicity p , a frequency chirp is added. This combination results in wide frequency bands for each harmonic. The transducer's conversion efficiency from the electrical to the acoustic domain is characterized optomechanically using single quantum dots acting as nanoscale pressure sensors. The ability to generate surface acoustic waves over a wide band of frequencies enables advanced acousto-optic spectroscopy using mode-locked lasers with fixed repetition rate. Stable phase locking between the electrically generated acoustic wave and the train of laser pulses is confirmed by performing stroboscopic spectroscopy on a single quantum dot at a frequency of 320 MHz. Finally, the dynamic spectral modulation of the quantum dot is directly monitored in the time domain combining stable phase-locked optical excitation and time-correlated single-photon counting. The demonstrated scheme will be particularly useful for the experimental implementation of surface-acoustic-wave-driven quantum gates of optically addressable qubits or collective quantum states or for multicomponent Fourier synthesis of tailored nanomechanical waveforms.

  11. Numerical Study and Optimisation of a Novel Single-Element Dual-Frequency Ultrasound Transducer

    Directory of Open Access Journals (Sweden)

    Changhe Sun

    2018-02-01

    Full Text Available A dual-frequency ultrasound transducer (DFUT is usually preferred for its numerous advantageous applications, especially in biomedical imaging and sensing. However, most of DFUTs are based on the combination of fundamental and harmonic operations, or integration of multiple different single-frequency ultrasound transducers, hindering perfect beam alignment and acoustic impedance matching. A novel single-element DFUT has been proposed in this paper. A small piezoelectric membrane is used as the high-frequency ultrasound transducer, which is stacked on a large non-piezoelectric elastic membrane with a groove used as the low-frequency capacitive ultrasound transducer. Such a capacitive-piezoelectric hybrid structure is theoretically analysed in details, based on the electrostatic attraction force and converse piezoelectric effect. Both the low and high resonance frequencies are independently derived, with a maximum deviation of less than 4% from the finite element simulations. Besides, a lumped-parameter equivalent circuit model of combining both the capacitive and piezoelectric ultrasound transducers was also described. Based on our dual-frequency structure design, a high-to-low frequency ratio of about 2 to more than 20 could be achieved, with easy and independent controllability of two frequencies, and the high-frequency operation shows at least an order-of-magnitude displacement sensitivity improvement compared with the conventional harmonic operations.

  12. A Structural Scale for the Factors of Waste Sensors and Transducers Recycling Based on Consumer Satisfaction

    Directory of Open Access Journals (Sweden)

    Ming Ke

    2014-01-01

    Full Text Available This article first introduced the research results of both domestic and foreign scholars on the factors of waste sensors and transducers recycling, and in consideration of the four main bodies in waste sensors and transducers recycling, 14 influencing indicators of waste sensors and transducers recycling are extracted. Then this paper designed a questionnaire according to the 15 indicators of waste home appliance recycling, and put it on a research website. After verification of reliability and validity of the questionnaire, this paper analyzed the influencing factors of waste sensors and transducers recycling by using SPSS 13.0. Finally this article used factor analysis method to identify the representative factors. Two factors are concluded: Factor 1 mainly represents laws and regulations of government, governmental subsidy, governmental technology support, governmental market guidance, governmental monitor and control, recycling knowledge publication by government, social responsibilities of producers and recyclers, technique disposition ability of producers and recyclers, recyclers' service, therefore it could be summarized as government and enterprise disposition capability; while Factor 2 mainly represents consumers' benefit from recycling, convenience of consumers' recycling, mental satisfaction of consumers from recycling, consumers' recycling knowledge, social recycling environment, and thus they could be summarized as consumer incentive factor. This paper would provide some references for the analysis and research on influencing factors of waste sensors and transducers recycling.

  13. Studying Maximum Plantar Stress per Insole Design Using Foot CT-Scan Images of Hyperelastic Soft Tissues

    Directory of Open Access Journals (Sweden)

    Ali Sarikhani

    2016-01-01

    Full Text Available The insole shape and the resulting plantar stress distribution have a pivotal impact on overall health. In this paper, by Finite Element Method, maximum stress value and stress distribution of plantar were studied for different insoles designs, which are the flat surface and the custom-molded (conformal surface. Moreover, insole thickness, heel’s height, and different materials were used to minimize the maximum stress and achieve the most uniform stress distribution. The foot shape and its details used in this paper were imported from online CT-Scan images. Results show that the custom-molded insole reduced maximum stress 40% more than the flat surface insole. Upon increase of thickness in both insole types, stress distribution becomes more uniform and maximum stress value decreases up to 10%; however, increase of thickness becomes ineffective above a threshold of 1 cm. By increasing heel height (degree of insole, maximum stress moves from heel to toes and becomes more uniform. Therefore, this scenario is very helpful for control of stress in 0.2° to 0.4° degrees for custom-molded insole and over 1° for flat insole. By changing the material of the insole, the value of maximum stress remains nearly constant. The custom-molded (conformal insole which has 0.5 to 1 cm thickness and 0.2° to 0.4° degrees is found to be the most compatible form for foot.

  14. Coupled electromechanical modeling of piezoelectric disc transducers for low-frequency ultrasonic collimated beam generation

    Science.gov (United States)

    Chillara, Vamshi Krishna; Pantea, Cristian; Sinha, Dipen N.

    2017-04-01

    Low-frequency ultrasonic collimated beam generation from radial modes of piezoelectric disc transducers is studied using a coupled electromechanical finite element approach. First, resonance and vibration characteristics of the radial modes of the disc transducers are obtained using an eigenfrequency analysis. The vibration patterns obtained from numerical simulation are compared with those obtained from experiments and are in good agreement. Next, ultrasonic beam profiles in water generated from the radial modes of a piezo-disc are studied. It was found that a free piezo-disc generates a Bessel-beam with multiple side-lobes. In contrast, clamping the lateral edges of the piezo-disc results in a well-collimated central beam with reduced side-lobes. This provides a novel transducer design for low-frequency collimated beam generation for imaging through highly attenuating materials

  15. Non-contact thermoacoustic detection of embedded targets using airborne-capacitive micromachined ultrasonic transducers

    Science.gov (United States)

    Nan, Hao; Boyle, Kevin C.; Apte, Nikhil; Aliroteh, Miaad S.; Bhuyan, Anshuman; Nikoozadeh, Amin; Khuri-Yakub, Butrus T.; Arbabian, Amin

    2015-02-01

    A radio frequency (RF)/ultrasound hybrid imaging system using airborne capacitive micromachined ultrasonic transducers (CMUTs) is proposed for the remote detection of embedded objects in highly dispersive media (e.g., water, soil, and tissue). RF excitation provides permittivity contrast, and ultra-sensitive airborne-ultrasound detection measures thermoacoustic-generated acoustic waves that initiate at the boundaries of the embedded target, go through the medium-air interface, and finally reach the transducer. Vented wideband CMUTs interface to 0.18 μm CMOS low-noise amplifiers to provide displacement detection sensitivity of 1.3 pm at the transducer surface. The carefully designed vented CMUT structure provides a fractional bandwidth of 3.5% utilizing the squeeze-film damping of the air in the cavity.

  16. D33 mode piezoelectric diaphragm based acoustic transducer with high sensitivity

    KAUST Repository

    Shen, Zhiyuan

    2013-01-01

    This paper presents the design, fabrication, and characterization of an acoustic transducer using a piezoelectric freestanding bulk diaphragm as the sensing element. The diaphragm bearing the spiral electrode operates in d 33 mode, which allows the in-plane deformation of the diaphragm to be converted to the out-of-plane deformation and generates an acoustic wave in the same direction. A finite element code is developed to reorient the material polarization distribution according to the poling field calculated. The first four resonance modes have been simulated and verified by impedance and velocity spectra. The sensitivity and the sound pressure level of the transducer were characterized. The realized sensitivity of 126.21 μV/Pa at 1 kHz is nearly twenty times of the sensitivity of a sandwich d31 mode transducer. © 2012 Elsevier B.V.

  17. Investigation of transducers for large-scale cryogenic systems in Italy

    International Nuclear Information System (INIS)

    Pavese, F.

    1984-01-01

    This chapter investigates temperature, pressure (static, absolute), strain and flowrate transducers. A modular cryostat system, which includes a superconducting solenoid, is used for measurements. The module for pressure transducers allows them to be measured one at a time. Adiabatic conditions for the functional part of the module for strain-gages are ensured by sliding thermal anchors. The equipment is driven by three computer-based systems which act separately. Magnetoresistance has been measured up to 6 T. Only foil-type strain gages were investigated. It is determined that apparent strain has a peculiar trend at liquid helium temperatures. Four types of transducers, specifically designed for low-temperature measurement of static, absolute pressure, and uncalibrated, were tested

  18. Stress !!!

    OpenAIRE

    Fledderus, M.

    2012-01-01

    Twee op de vijf UT-studenten hebben last van ernstige studiestress, zo erg zelfs dat het ze in hun privéleven belemmert. Die cijfers komen overeen met het landelijk beeld van stress onder studenten. Samen met 14 andere universiteits- en hogeschoolbladen enquêteerde UT Nieuws bijna 5500 studenten. Opvallend is dat mannelijke studenten uit Twente zich veel minder druk lijken te maken over hun studie. Onder vrouwen ligt de stress juist erg hoog ten opzichte van het landelijk gemiddelde.

  19. Stress

    DEFF Research Database (Denmark)

    Keller, Hanne Dauer

    2015-01-01

    Kapitlet handler om stress som følelse, og det trækker primært på de få kvalitative undersøgelser, der er lavet af stressforløb.......Kapitlet handler om stress som følelse, og det trækker primært på de få kvalitative undersøgelser, der er lavet af stressforløb....

  20. Effects of the implant design on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis of original computer-aided design models.

    Science.gov (United States)

    Yamanishi, Yasufumi; Yamaguchi, Satoshi; Imazato, Satoshi; Nakano, Tamaki; Yatani, Hirofumi

    2014-09-01

    Occlusal overloading causes peri-implant bone resorption. Previous studies examined stress distribution in alveolar bone around commercial implants using three-dimensional (3D) finite element analysis. However, the commercial implants contained some different designs. The purpose of this study is to reveal the effect of the target design on peri-implant bone stress and abutment micromovement. Six 3D implant models were created for different implant-abutment joints: 1) internal joint model (IM); 2) external joint model (EM); 3) straight abutment (SA) shape; 4) tapered abutment (TA) shapes; 5) platform switching (PS) in the IM; and 6) modified TA neck design (reverse conical neck [RN]). A static load of 100 N was applied to the basal ridge surface of the abutment at a 45-degree oblique angle to the long axis of the implant. Both stress distribution in peri-implant bone and abutment micromovement in the SA and TA models were analyzed. Compressive stress concentrated on labial cortical bone and tensile stress on the palatal side in the EM and on the labial side in the IM. There was no difference in maximum principal stress distribution for SA and TA models. Tensile stress concentration was not apparent on labial cortical bone in the PS model (versus IM). Maximum principal stress concentrated more on peri-implant bone in the RN than in the TA model. The TA model exhibited less abutment micromovement than the SA model. This study reveals the effects of the design of specific components on peri-implant bone stress and abutment displacement after implant-supported single restoration in the anterior maxilla.

  1. Optimisation of a Cymbal Transducer for Its Use in a High-power Ultrasonic Cutting Device for Bone Surgery

    Science.gov (United States)

    Bejarano, Fernando; Feeney, Andrew; Lucas, Margaret

    The class V cymbal is a flextensional transducer commonly used in low-power ultrasonic applications. The resonance frequency of the transducer can be tailored by the choice of end-cap and driver materials, and the dimensions of the end-caps. The cymbal transducer has one significant limitation which restricts the operational vibration amplitude of the device. This is the limit imposed by the mechanical strength of the bonding agent between the metal end-cap and the piezoceramic driver. Therefore, when there is an increase in the input power or displacement, the stresses in the bonding layer can lead to debonding, thereby rendering the cymbal transducer ineffective for high-power ultrasonic applications. In this paper, several experimental analyses have been performed, complemented by the use of Abaqus/CAE finite element analysis, in order to develop a high-power ultrasonic cutting device for bone surgery using a new configuration of cymbal transducer, which is optimised for operation at high displacement and high input power. This new transducer uses a combination of a piezoceramic disc with a metal ring as the driver, thereby improving the mechanical coupling with the metal end-cap.

  2. Design, rationale and feasibility of a multidimensional experimental protocol to study early life stress

    Directory of Open Access Journals (Sweden)

    M. Dillwyn Bartholomeusz

    2017-09-01

    Full Text Available There is a rapidly accumulating body of evidence regarding the influential role of early life stress (ELS upon medical and psychiatric conditions. While self-report instruments, with their intrinsic limitations of recall, remain the primary means of detecting ELS in humans, biological measures are generally limited to a single biological system. This paper describes the design, rationale and feasibility of a study to simultaneously measure neuroendocrine, immune and autonomic nervous system (ANS responses to psychological and physiological stressors in relation to ELS. Five healthy university students were recruited by advertisement. Exclusion criteria included chronic medical conditions, psychotic disorders, needle phobia, inability to tolerate pain, and those using anti-inflammatory medications. They were clinically interviewed and physiological recordings made over a two-hour period pre, during and post two acute stressors: the cold pressor test and recalling a distressing memory. The Childhood Trauma Questionnaire and the Parental Bonding Index were utilised to measure ELS. Other psychological measures of mood and personality were also administered. Measurements of heart rate, blood pressure, respiratory rate, skin conductance, skin blood flow and temporal plasma samples were successfully obtained before, during and after acute stress. Participants reported the extensive psychological and multisystem physiological data collection and stress provocations were tolerable. Most (4/5 participants indicated a willingness to return to repeat the protocol, indicating acceptability. Our protocol is viable and safe in young physically healthy adults and allows us to assess simultaneously neuroendocrine, immune and autonomic nervous system responses to stressors in persons assessed for ELS. Keywords: Childhood-stress, Adverse-childhood-events, Childhood-trauma questionnaire, Parental-bonding-instrument, Type D scale (DS14

  3. Real-time fast ultrasonic monitoring of concrete cracking using embedded piezoelectric transducers

    Science.gov (United States)

    Dumoulin, Cédric; Deraemaeker, Arnaud

    2017-10-01

    This paper deals with the use of embedded piezoelectric transducers for ultrasonic monitoring of cracking in concrete. Based on the previous developments of our research team on that topic, we design a new data acquisition system which is able to interrogate the emitter-receiver pair up to 150 times per second. The system is based on low-voltage actuation (up to 20 V) and the signal-to-noise ratio is excellent due to the use of a voltage amplifier at the receiver side and the possibility to perform averages. With such a high measurement rate, we are able to follow brittle failure events such as the failure of a concrete cylinder in compression, which is the application example presented. In this application, we show that, in addition to the ultrasonic active monitoring of cracking, the system is also able to record the passive acoustic emission events which can be used as a complementary indicator of damage in the cylinder. We also demonstrate that because of the high level of stresses in compression, the damage indicator defined in our previous studies is not suited for crack monitoring due to the elastoacoustic effect. The amplitude of the first wave arrival is shown to be a robust alternative damage indicator allowing to follow accurately the three successive phases of cracking leading to the failure of the cylinder.

  4. Medium- and high-pressure gauges and transducers produced by laser welding technology

    Science.gov (United States)

    Daurelio, Giuseppe; Nenci, Fabio; Cinquepalmi, Massimo; Chita, Giuseppe

    1998-07-01

    Industrial manufacturers produce many types of pressure gauges and transducers according to the applications, for gas or liquid, for high-medium and low pressure ranges. Nowadays the current production technology generally prefers to weld by micro TIG source the metallic corrugated membranes to the gauge or transducer bodies for the products, operating on the low pressure or medium pressure ranges. For the other ones, operating to high pressure range, generally the two components of the transducers are both threaded only and threaded and then circularly welded by micro TIG for the other higher range, till to 1000 bar. In this work the products, operating on the approximately equals 30 divided by 200 bar, are considered. These, when assembled on industrial plants, as an outcome of a non-correct operating sequence, give a 'shifted' electrical signal. This is due to a shift of the 'zero electrical signal' that unbalances the electrical bridge - thin layer sensor - that is the sensitive part of the product. Moreover, for the same problem, often some mechanical settlings of the transducer happen during the first pressure semi-components, with an increasing of the product manufacturing costs. In light of all this, the above referred, in this work the whole transducer has been re-designed according to the specific laser welding technology requirements. On the new product no threaded parts exist but only a circular laser welding with a full penetration depth about 2.5 divided by 3 mm high. Three different alloys have been tested according to the applications and the mechanical properties requested to the transducer. By using a 1.5 KW CO2 laser system many different working parameters have been evaluated for correlating laser parameters to the penetration depths, crown wides, interaction laser-materia times, mechanical and metallurgical properties. Moreover during the laser welding process the measurements of the maximum temperature, reached by the transducer top, has been

  5. Stress adapted embroidered meshes with a graded pattern design for abdominal wall hernia repair

    Science.gov (United States)

    Hahn, J.; Bittrich, L.; Breier, A.; Spickenheuer, A.

    2017-10-01

    Abdominal wall hernias are one of the most relevant injuries of the digestive system with 25 million patients in 2013. Surgery is recommended primarily using allogenic non-absorbable wrap-knitted meshes. These meshes have in common that their stress-strain behaviour is not adapted to the anisotropic behaviour of native abdominal wall tissue. The ideal mesh should possess an adequate mechanical behaviour and a suitable porosity at the same time. An alternative fabrication method to wrap-knitting is the embroidery technology with a high flexibility in pattern design and adaption of mechanical properties. In this study, a pattern generator was created for pattern designs consisting of a base and a reinforcement pattern. The embroidered mesh structures demonstrated different structural and mechanical characteristics. Additionally, the investigation of the mechanical properties exhibited an anisotropic mechanical behaviour for the embroidered meshes. As a result, the investigated pattern generator and the embroidery technology allow the production of stress adapted mesh structures that are a promising approach for hernia reconstruction.

  6. Capacitive micromachined ultrasonic transducer based tilt sensing

    Science.gov (United States)

    Yu, Hongbin; Guo, Bin; Haridas, Kuruveettil; Lin, Tsu-Hui; Hao Cheong, Jia; Lin Tsai, Ming; Boon Yee, Tack

    2012-10-01

    In this paper, a tilt sensing mechanism based on the capacitive micromachined ultrasound transducers (CMUTs) is presented. By measuring the difference in the time of flight of various pulse-echo signals from different CMUT transmitting elements to one common receiving element in the oil bath, the tilt angle of the oil surface can be determined. With the proposed device, the maximum tilt angles of 20° and 28° have been measured in the clockwise and counterclockwise directions, respectively, and the difference between the measured and the theoretical values of the tilt angle was found to be within 0.05° during the whole test.

  7. Na, K-ATPase as signaling transducer

    OpenAIRE

    Li, Juan

    2007-01-01

    It is now generally agreed that Na,K-ATPase (NKA), in addition to its role in the maintenance of Na+ and K+ gradients across the cell membrane, is a signal transducer. Our group has identified a novel signaling pathway where NKA interact with IP3R to form a signaling microdomain. Ouabain, a specific ligand of NKA, activates this pathway, triggers slow Ca2+ oscillations and activates NF-κB. In current study, the molecular mechanisms and some important downstream effects of NK...

  8. A novel coping design to decrease maximum principal stress in zirconia ceramic restorations.

    Science.gov (United States)

    Sung, MooGyung; Han, Chong-Hyun; Kim, Sunjai

    2014-10-01

    The objective of this study was to evaluate the influence of coping design modifications on maximum first principal stress (MPS) in a mathematical zirconia ceramic crown model. For a nonlinear, 3D finite element analysis, a simplified tooth model was built on the basis of the average dimensions of mandibular second molars. Virtual tooth reduction was performed to model an abutment with a flat occlusal surface and 16° convergence angle between facing walls. The cement layer was set to a thickness of 100 μm. Three different copings-one with 0.5-mm constant thickness; one with constant thickness and extended lingual and proximal collars; and a novel design with zirconia beam reinforcement-were designed to simulate zirconia ceramic restorations. The novel design had strategically positioned zirconia beams on the lingual and marginal ridges to protect veneer ceramics, and was divided into three subdesigns according to the width of the zirconia beam (0.5, 0.8, and 1 mm). Combinations of vertical and horizontal load were applied over the distolingual marginal ridge, and the MPSs were evaluated. The novel design showed the lowest MPS in veneer ceramics under most loading conditions. The only exception to this was the novel design with a 0.5-mm zirconia beam width under mesial horizontal load. Compared to constant thickness coping with or without extended collars, the novel coping design reduced MPS in veneer ceramics; however, narrow zirconia beams should be avoided to prevent elevations in MPS in veneer ceramic layers. © 2014 by the American College of Prosthodontists.

  9. Ultrasonic Cutting Device for Bone Surgery Based on a Cymbal Transducer

    Science.gov (United States)

    Bejarano, F.; Lucas, M.; Wallace, R.; Spadaccino, A. M.; Simpson, H.

    In this study, we introduce a new prototype ultrasonic cutting device for bone surgery based on a class V flextensional cymbal transducer, configured for use in power ultrasonics applications, which removes many of the geometrical restrictions on the cutting tip of Langevin-based transducers. The benefit of incorporating a cymbal transducer is that since the cutting blade itself does not have to be tuned, blade design can focus more closely on delivering the best interaction with bone to provide a highly accurate cut. Small variations to the geometry of the blade do not affect the final resonance frequency. Also the ultrasonic device can be miniaturised to allow the design of devices for delicate orthopaedic procedures involving minimal-access surgery. The results show how the cymbal transducer, driven by a single piezoceramic disc, can excite sufficiently high vibration displacement amplitudes at lower driving voltages. This is achieved by adapting the configuration of the cymbal to remove the problem of epoxy layer debonding, and by optimising the cymbal end-cap and geometry through finite element modelling supported with experimental vibration characterisation. Preliminary characterisations of the resulting prototype ultrasonic bone cutting device, which operates at around 25 kHz, illustrate the success of this novel device design.

  10. Parameter sensitivity study of a Field II multilayer transducer model on a convex transducer

    DEFF Research Database (Denmark)

    Bæk, David; Jensen, Jørgen Arendt; Willatzen, Morten

    2009-01-01

    ultrasound imaging transducer (Bæk et al. ICU 2009). The model benefits from its 1D simplicity and hasshown to give an amplitude error around 1.7‐2 dB. However, any prediction of amplitude, phase, and attenuation of pulses relies on the accuracy of manufacturer supplied material characteristics, which may...

  11. Fundamentals for remote structural health monitoring of wind turbine blades - a preproject. Annex C. Fibre transducer for damage detection in adhesive layers of wind turbine blades

    DEFF Research Database (Denmark)

    Sendrup, P.

    2002-01-01

    displacement transducer for detection of damage in adhesive layers of wind turbine blades. It was chosen to base the transducer on the fibre optic micro-bend principle. The report contains the result of measurementsand optical simulations of light transmittance through optical fibres with micro......-bends and a suggestion for a micro-bend transducer design specifically suitable for detection of damage in adhesive layers between larger composite structures, as the shellsin a wind turbine blade. Such a damage will cause the joined parts to move slightly relative to each other, and the transducer is designed to change...... of 40 um.The sensitivity is anticipated to be sufficient the application, because fully evolved cracks in the adhesive layer typically has a opening of 100 um - 200 um. The tests of the transducer ability to detect damage in adhesive layers both in the lab-testand in the 'full scale test' were also...

  12. Transduced PEP-1-PON1 proteins regulate microglial activation and dopaminergic neuronal death in a Parkinson's disease model.

    Science.gov (United States)

    Kim, Mi Jin; Park, Meeyoung; Kim, Dae Won; Shin, Min Jea; Son, Ora; Jo, Hyo Sang; Yeo, Hyeon Ji; Cho, Su Bin; Park, Jung Hwan; Lee, Chi Hern; Kim, Duk-Soo; Kwon, Oh-Shin; Kim, Joon; Han, Kyu Hyung; Park, Jinseu; Eum, Won Sik; Choi, Soo Young

    2015-09-01

    Parkinson's disease (PD) is an oxidative stress-mediated neurodegenerative disorder caused by selective dopaminergic neuronal death in the midbrain substantia nigra. Paraoxonase 1 (PON1) is a potent inhibitor of low-density lipoprotein (LDL) and high-density lipoprotein (HDL) against oxidation by destroying biologically active phospholipids with potential protective effects against oxidative stress-induced inflammatory disorders. In a previous study, we constructed protein transduction domain (PTD) fusion PEP-1-PON1 protein to transduce PON1 into cells and tissue. In this study, we examined the role of transduced PEP-1-PON1 protein in repressing oxidative stress-mediated inflammatory response in microglial BV2 cells after exposure to lipopolysaccharide (LPS). Moreover, we identified the functions of transduced PEP-1-PON1 proteins which include, mitigating mitochondrial damage, decreasing reactive oxidative species (ROS) production, matrix metalloproteinase-9 (MMP-9) expression and protecting against 1-methyl-4-phenylpyridinium (MPP(+))-induced neurotoxicity in SH-SY5Y cells. Furthermore, transduced PEP-1-PON1 protein reduced MMP-9 expression and protected against dopaminergic neuronal cell death in a 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP)-induced PD mice model. Taken together, these results suggest a promising therapeutic application of PEP-1-PON1 proteins against PD and other inflammation and oxidative stress-related neuronal diseases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Electromagnetic acoustic transducers noncontacting ultrasonic measurements using EMATS

    CERN Document Server

    Hirao, Masahiko

    2017-01-01

    This second edition provides comprehensive information on electromagnetic acoustic transducers (EMATs), from the theory and physical principles of EMATs to the construction of systems and their applications to scientific and industrial ultrasonic measurements on materials. The original version has been complemented with selected ideas on ultrasonic measurement that have emerged since the first edition was released. The book is divided into four parts: PART I offers a self-contained description of the basic elements of coupling mechanisms along with the practical designing of EMATs for various purposes. Several implementations to compensate for EMATs’ low transfer efficiency are provided, along with useful tips on how to make an EMAT. PART II describes the principle of electromagnetic acoustic resonance (EMAR), which makes the most of EMATs’ contactless nature and is the most successful amplification mechanism for precise measurements of velocity and attenuation. PART III applies EMAR to studying physical ...

  14. The electro-mechanical behaviour of flexural ultrasonic transducers

    Science.gov (United States)

    Dixon, Steve; Kang, Lei; Ginestier, Michael; Wells, Christopher; Rowlands, George; Feeney, Andrew

    2017-05-01

    Flexural ultrasonic transducers are capable of high electro-mechanical coupling efficiencies for the generation or detection of ultrasound in fluids. They are the most common type of ultrasonic sensor, commonly used in parking sensors, because the devices are efficient, robust, and inexpensive. The simplest design consists of a piezoelectric disc, bonded to the inner surface of a metal cap, the face of which provides a vibrating membrane for the generation or detection of ultrasonic waves in fluids. Experimental measurements demonstrate that during the excitation of the piezoelectric element by an electrical voltage, there are three characteristic regions, where the frequency of the emitted ultrasonic wave changes during the excitation, steady-state, and the final decay process. A simple mechanical analogue model is capable of describing this behaviour.

  15. Tunable acoustic metamaterial based on piezoelectric ceramic transducer

    Science.gov (United States)

    Zhu, Xiaohui; Qiao, Jing; Zhang, Guangyu; Zhou, Qiang; Wu, Yingdan; Li, Longqiu

    2017-04-01

    In this paper, a tunable metamaterial consisting of periodic layers of steel, polyurea and piezoelectric ceramic transducer (PZT) was presented. The PZT layer in this structure was connected to an inductor L. Transfer matrix method was used to calculate the band structure of the sample. It was observed that an extremely narrow stop band was induced by the PZT layer with inductor L. This narrow stop band was attributed to the resonance circuit constituted by the piezoelectric layer, for the piezoelectric layer with electrodes could be seen as a capacitor. Further, homogenization was used to calculate the effective elastic constants of the sample. Results showed that the effective parameters of this structure behaved negative in the narrow stop band. The location of the narrow stop band was in the charge of inductor L, which could be used to design acoustic filters or noise insulators by changing the parameters of structure.

  16. A Patient Specific Biomechanical Analysis of Custom Root Analogue Implant Designs on Alveolar Bone Stress: A Finite Element Study

    Directory of Open Access Journals (Sweden)

    David Anssari Moin

    2016-01-01

    Full Text Available Objectives. The aim of this study was to analyse by means of FEA the influence of 5 custom RAI designs on stress distribution of peri-implant bone and to evaluate the impact on microdisplacement for a specific patient case. Materials and Methods. A 3D surface model of a RAI for the upper right canine was constructed from the cone beam computed tomography data of one patient. Subsequently, five (targeted press-fit design modification FE models with five congruent bone models were designed: “Standard,” “Prism,” “Fins,” “Plug,” and “Bulbs,” respectively. Preprocessor software was applied to mesh the models. Two loads were applied: an oblique force (300 N and a vertical force (150 N. Analysis was performed to evaluate stress distributions and deformed contact separation at the peri-implant region. Results. The lowest von Mises stress levels were numerically observed for the Plug design. The lowest levels of contact separation were measured in the Fins model followed by the Bulbs design. Conclusions. Within the limitations of the applied methodology, adding targeted press-fit geometry to the RAI standard design will have a positive effect on stress distribution, lower concentration of bone stress, and will provide a better primary stability for this patient specific case.

  17. Three Dimensional Finite Element Analysis of Distal Abutment Stresses of Removable Partial Dentures with Different Retainer Designs

    Science.gov (United States)

    Zarrati, Simindokht; Heidari, Fatemeh; Kashani, Jamal

    2015-01-01

    Objectives: This finite element method study aimed to compare the amount of stress on an isolated mandibular second premolar in two conventional reciprocal parallel interface designs of removable partial dentures (RPDs) and the same RPD abutment tooth (not isolated). Materials and Methods: A Kennedy Class 1, modification 1 RPD framework was simulated on a 3D model of mandible with three different designs: an isolated tooth with a mesial rest, an isolated tooth with mesial and distal rests and an abutment with a mesial rest (which was not isolated); 26 N occlusal forces were exerted bilaterally on the first molar sites. Stress on the abutment teeth was analyzed using Cosmos Works 2009 Software. Results: In all designs, the abutment tooth stress concentration was located in the buccal alveolar crest. In the first model, the von Mises stress distribution in the contact area of I-bar clasp and cervical portion of the tooth was 19 MPa and the maximum stress was 30 MPa. In the second model, the maximum von Mises stress distribution was 15 MPa in the cervical of the tooth. In the third model, the maximum von Mises stress was located in the cervical of the tooth and the distal proximal plate. Conclusion: We recommend using both mesial and distal rests on the distal abutment teeth of distal extension RPDs. The abutment of an extension base RPD, which is not isolated in presence of its neighboring more anterior tooth, may have a better biomechanical prognosis. PMID:26884772

  18. Stress and displacement analysis of a modern design lathe body by the fi nite element method (FEM

    Directory of Open Access Journals (Sweden)

    R. Staniek

    2012-01-01

    Full Text Available The Finite element method (FEM was used in this study for the analysis of the strain and stress of a turning machine body. The fi nal design decisions were made on the basis of stress and displacement fi eld analysis of various design versions related to the structure of the considered machine tool. The results presented in this paper will be helpful for practical static and dynamic strength evaluation as well as for the appropriate design of machine tools using the FEM.

  19. Stress !!!

    NARCIS (Netherlands)

    Fledderus, M.

    2012-01-01

    Twee op de vijf UT-studenten hebben last van ernstige studiestress, zo erg zelfs dat het ze in hun privéleven belemmert. Die cijfers komen overeen met het landelijk beeld van stress onder studenten. Samen met 14 andere universiteits- en hogeschoolbladen enquêteerde UT Nieuws bijna 5500 studenten.

  20. Monitoring of composite structures using a network of integrated PVDF film transducers

    Science.gov (United States)

    Guzmán, Enrique; Cugnoni, Joël; Gmür, Thomas

    2015-05-01

    Aiming to reduce costs, polyvinylidene difluoride (PVDF) film patches are an emerging alternative to more classic piezoelectric technologies, like ceramic patches, as transducers to measure local deformation in many structural applications. This choice is supported by advantages such as the low weight and mechanical flexibility of PVDF, making this polymer suitable for embedding inside full scale polymer based composite structures. Piezoelectric transducer patches can be used as actuators to dynamically excite full-scale composite structures, and as sensors to measure the strain. The main objective of this paper is to verify that the PVDF transducers can provide exploitable signals in the context of structural health monitoring. In order to do so, two aspects of the design of transducer network are investigated: the optimization of the sensor network, for which the effective independence method is proposed, and the use of operational modal analysis (OMA), since it is a simple method to extract the natural frequencies of a structure from a time series. The results of the analysis are compared to a reference set issued from experimental modal analysis (EMA), a simple, well-known, classic method, which is carried out using accelerometers and an impact hammer. By statistical means, it is shown that there is no significant difference between the two methods, and an optimized PVDF transducer network combined with OMA can perform the dynamic analysis of a structure as well as a classic EMA setup would do. This leads the way to the use of low-cost PVDF embedded transducer networks for robust composite material characterization.

  1. A structural health monitoring system with ultrasonic MEMS transducers

    Science.gov (United States)

    Guldiken, Rasim O.; Onen, Onursal; Gul, Mustafa; Catbas, F. Necati

    2011-04-01

    In this paper, we will summarize our efforts on exploring guided acoustic waves generated by MEMS ultrasonic transducers enabling a non-destructive, ultra-low powered, wireless SHM system. State-of-the-art SHM systems employ bulk piezoelectric transducers. However, they are not environmentally benign (contain lead), not cost feasible for monitoring every bridge in the U.S., require significant power for operation, lack integration capability for wireless interrogation, need precise matching layers, and have only 25-50 percent fractional bandwidth, limiting the detection resolution. To alleviate most of these shortcomings, a low impedance MEMS transducer, called a capacitive micromachined ultrasonic transducer (CMUT), is explored.

  2. Calibration of Field II using a Convex Ultrasound Transducer

    DEFF Research Database (Denmark)

    Bæk, David; Jensen, Jørgen Arendt; Willatzen, Morten

    2010-01-01

    of the transducer. For such simulations to reflect actual measured intensities and pressure levels, the transducer impulse response is to be known. This work presents the results of combining a modified form of a 1D linear transducer model originally suggested by Willatzen with the Field II program to calibrate...... BK-Medical (Herlev, Denmark). As input waveform for the Field model we measured the output voltage of the research amplifier, which peak voltage was limited to 31 V to avoid too high non linear effects. We measured the hydrophone output from three transducer front elements by averaging 40 shoot...

  3. GASICA : Design, validation and use of a system for inducing and controlling physiological stress

    NARCIS (Netherlands)

    van der Vijgh, B.H.

    2016-01-01

    Stress is a prevalent condition in the Western world. In the Netherlands, a recent study reported the costs of stress to be around 4 billion euro per year, only factoring in work-related stress. In addition, the societal and individual impact of stress is high: the same study estimated that every

  4. Front-end receiver electronics for a matrix transducer for 3-D transesophageal echocardiography.

    Science.gov (United States)

    Yu, Zili; Blaak, Sandra; Chang, Zu-yao; Yao, Jiajian; Bosch, Johan G; Prins, Christian; Lancée, Charles T; de Jong, Nico; Pertijs, Michiel A P; Meijer, Gerard C M

    2012-07-01

    There is a clear clinical need for creating 3-D images of the heart. One promising technique is the use of transesophageal echocardiography (TEE). To enable 3-D TEE, we are developing a miniature ultrasound probe containing a matrix piezoelectric transducer with more than 2000 elements. Because a gastroscopic tube cannot accommodate the cables needed to connect all transducer elements directly to an imaging system, a major challenge is to locally reduce the number of channels, while maintaining a sufficient signal-to-noise ratio. This can be achieved by using front-end receiver electronics bonded to the transducers to provide appropriate signal conditioning in the tip of the probe. This paper presents the design of such electronics, realizing time-gain compensation (TGC) and micro-beamforming using simple, low-power circuits. Prototypes of TGC amplifiers and micro-beamforming cells have been fabricated in 0.35-μm CMOS technology. These prototype chips have been combined on a printed circuit board (PCB) to form an ultrasound-receiver system capable of reading and combining the signals of three transducer elements. Experimental results show that this design is a suitable candidate for 3-D TEE.

  5. Designing automation for complex work environments under different levels of stress.

    Science.gov (United States)

    Sauer, Juergen; Nickel, Peter; Wastell, David

    2013-01-01

    This article examines the effectiveness of different forms of static and adaptable automation under low- and high-stress conditions. Forty participants were randomly assigned to one of four experimental conditions, comparing three levels of static automation (low, medium and high) and one level of adaptable automation, with the environmental stressor (noise) being varied as a within-subjects variable. Participants were trained for 4 h on a simulation of a process control environment, called AutoCAMS, followed by a 2.5-h testing session. Measures of performance, psychophysiology and subjective reactions were taken. The results showed that operators preferred higher levels of automation under noise than under quiet conditions. A number of parameters indicated negative effects of noise exposure, such as performance impairments, physiological stress reactions and higher mental workload. It also emerged that adaptable automation provided advantages over low and intermediate static automation, with regard to mental workload, effort expenditure and diagnostic performance. The article concludes that for the design of automation a wider range of operational scenarios reflecting adverse as well as ideal working conditions needs to be considered. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  6. Highly reliable multisensor array (MSA) smart transducers

    Science.gov (United States)

    Perotti, José; Lucena, Angel; Mackey, Paul; Mata, Carlos; Immer, Christopher

    2006-05-01

    Many developments in the field of multisensor array (MSA) transducers have taken place in the last few years. Advancements in fabrication technology, such as Micro-Electro-Mechanical Systems (MEMS) and nanotechnology, have made implementation of MSA devices a reality. NASA Kennedy Space Center (KSC) has been developing this type of technology because of the increases in safety, reliability, and performance and the reduction in operational and maintenance costs that can be achieved with these devices. To demonstrate the MSA technology benefits, KSC quantified the relationship between the number of sensors (N) and the associated improvement in sensor life and reliability. A software algorithm was developed to monitor and assess the health of each element and the overall MSA. Furthermore, the software algorithm implemented criteria on how these elements would contribute to the MSA-calculated output to ensure required performance. The hypothesis was that a greater number of statistically independent sensor elements would provide a measurable increase in measurement reliability. A computer simulation was created to answer this question. An array of N sensors underwent random failures in the simulation and a life extension factor (LEF equals the percentage of the life of a single sensor) was calculated by the program. When LEF was plotted as a function of N, a quasiexponential behavior was detected with marginal improvement above N = 30. The hypothesis and follow-on simulation results were then corroborated experimentally. An array composed of eight independent pressure sensors was fabricated. To accelerate sensor life cycle and failure and to simulate degradation over time, the MSA was exposed to an environmental tem-perature of 125°C. Every 24 hours, the experiment's environmental temperature was returned to ambient temperature (27°C), and the outputs of all the MSA sensor elements were measured. Once per week, the MSA calibration was verified at five different

  7. Development of piezoelectric composites for transducers

    Science.gov (United States)

    Safari, A.

    1994-07-01

    For the past decade and a half, many different types of piezoelectric ceramic-polymer composites have been developed intended for transducer applications. These diphasic composites are prepared from non-active polymer, such as epoxy, and piezoelectric ceramic, such as PZT, in the form of filler powders, elongated fibers, multilayer and more complex three-dimensional structures. For the last four years, most of the efforts have been given to producing large area and fine scale PZT fiber composites. In this paper, processing of piezoelectric ceramic-polymer composites with various connectivity patterns are reviewed. Development of fine scale piezoelectric composites by lost mold, injection molding and the relic method are described. Research activities of different groups for preparing large area piezocomposites for hydrophone and actuator applications are briefly reviewed. Initial development of electrostrictive ceramics and composites are also

  8. Anodic bonding using SOI wafer for fabrication of capacitive micromachined ultrasonic transducers

    International Nuclear Information System (INIS)

    Bellaredj, M; Bourbon, G; Walter, V; Moal, P Le; Berthillier, M

    2014-01-01

    In medical ultrasound imaging, mostly piezoelectric crystals are used as ultrasonic transducers. Capacitive micromachined ultrasonic transducers (CMUTs) introduced around 1994 have been shown to be a good alternative to conventional piezoelectric transducers in various aspects, such as sensitivity, transduction efficiency or bandwidth. This paper focuses on a fabrication process for CMUTs using anodic bonding of a silicon on insulator wafer on a glass wafer. The processing steps are described leading to a good control of the mechanical response of the membrane. This technology makes possible the fabrication of large membranes and can extend the frequency range of CMUTs to lower frequencies of operation. Silicon membranes having radii of 50, 70, 100 and 150 µm and a 1.5 µm thickness are fabricated and electromechanically characterized using an auto-balanced bridge impedance analyzer. Resonant frequencies from 0.6 to 2.3 MHz and an electromechanical coupling coefficient around 55% are reported. The effects of residual stress in the membranes and uncontrolled clamping conditions are clearly responsible for the discrepancies between experimental and theoretical values of the first resonance frequency. The residual stress in the membranes is determined to be between 90 and 110 MPa. The actual boundary conditions are between the clamped condition and the simply supported condition and can be modeled with a torsional stiffness of 2.10 −7  Nm rad –1  in the numerical model. (paper)

  9. Smart concrete slabs with embedded tubular PZT transducers for damage detection

    Science.gov (United States)

    Gao, Weihang; Huo, Linsheng; Li, Hongnan; Song, Gangbing

    2018-02-01

    The objective of this study is to develop a new concept and methodology of smart concrete slab (SCS) with embedded tubular lead zirconate titanate transducer array for image based damage detection. Stress waves, as the detecting signals, are generated by the embedded tubular piezoceramic transducers in the SCS. Tubular piezoceramic transducers are used due to their capacity of generating radially uniform stress waves in a two-dimensional concrete slab (such as bridge decks and walls), increasing the monitoring range. A circular type delay-and-sum (DAS) imaging algorithm is developed to image the active acoustic sources based on the direct response received by each sensor. After the scattering signals from the damage are obtained by subtracting the baseline response of the concrete structures from those of the defective ones, the elliptical type DAS imaging algorithm is employed to process the scattering signals and reconstruct the image of the damage. Finally, two experiments, including active acoustic source monitoring and damage imaging for concrete structures, are carried out to illustrate and demonstrate the effectiveness of the proposed method.

  10. Stress transmission in soil

    DEFF Research Database (Denmark)

    Lamandé, Mathieu; Schjønning, Per

    We urgently need increased quantitative knowledge on stress transmission in real soils loaded with agricultural machinery. 3D measurements of vertical stresses under tracked wheels were performed in situ in a Stagnic Luvisol (clay content 20 %) continuously cropped with small grain cereals......). Seven load cells were inserted horizontally from a pit with minimal disturbance of soil in each of three depths (0.3, 0.6 and 0.9 m), covering the width of the wheeled area. The position of the wheel relative to the transducers was recorded using a laser sensor. Finally, the vertical stresses near...... the soil-tyre interface were measured in separate tests by 17 stress transducers across the width of the tyres. The results showed that the inflation pressure controlled the level of maximum stresses at 0.3 m depth, while the wheel load was correlated to the measured stresses at 0.9 m depth. This supports...

  11. Design for limit stresses of orange fruits (Citrus sinensis under axial and radial compression as related to transportation and storage design

    Directory of Open Access Journals (Sweden)

    Christopher Chukwutoo Ihueze

    2017-01-01

    Full Text Available This article employed the Hertz contact stress theory and the finite element method to evaluate the maximum contact pressure and the limit stresses of orange fruit under transportation and storage. The elastic properties of orange fruits subjected to axial and axial contact were measured such that elastic limit force, elastic modulus, Poisson’s ratio and bioyield stress were obtained as 18 N, 0.691 MPa, 0.367, 0.009 MPa for axial compression and for radial loading were 15.69 N, 0.645 MPa, 0.123, 0.010 MPa. The Hertz maximum contact pressure was estimated for axial and radial contacts as 0.036 MPa. The estimated limiting yield stress estimated as von Mises stresses for the induced surface stresses of the orange topologies varied from 0.005 MPa–0.03 MPa. Based on the distortion energy theory (DET the yield strength of orange fruit is recommended as 0.03 MPa while based on the maximum shear stress theory (MSST is 0.01 MPa for the design of orange transportation and storage system.

  12. A review of stress concentration factors in tubular and non-tubular joints for design of offshore installations

    Directory of Open Access Journals (Sweden)

    Dikshant Singh Saini

    2016-09-01

    Full Text Available Tubular structures are widely used in offshore installations, trusses, high rise buildings, towers for wind turbines, ski-lift installations, lightning, road pole signals etc., owing to their excellent structural performance and attractive appearance. Stress concentration, especially in the welded joints of these structures, is an important design consideration particularly for fatigue design. In the context of tubular and non-tubular joints, this paper provides a review of the experimental and numerical studies that have been carried out so far to determine the stress concentration factor (SCF. Emphasis is also placed on the complexity of capturing different types of stresses in tubular/non-tubular joints for estimation of SCF. Present code provisions for evaluation of SCF are also discussed. Further, a few issues, which require significant research effort to advance our understanding and to improve the current design guidelines, have been identified.

  13. Monitoring of the submerged arc welding process using current and voltage transducers

    International Nuclear Information System (INIS)

    Barrera, G.; Velez, M.; Espinosa, M.A.; Santos, O.; Barrera, E.; Gomez, G.

    1996-01-01

    Welding by fusion is one of the most used techniques to join materials in the manufacture industry. given the increase in applications of this welding process and the demand of more quality in the welding deposits, these welding processes are good candidates for the improvement of their instrumentation and control. Any improvement in the control technique will have a positive effect in the quality and productivity of the welding process. Some of the most significant variables in the submerged arc welding process are: current, voltage and torch speed. For the instrumentation of this research work, two transducers were designed, one for CD current monitoring and one for CD voltage monitoring of the welding machine. The design of both transducers includes an isolation amplifier. Graphical programming and the concept of virtual instrumentation were the main tools used for the design of the data acquisition system and the signal processing task. (Author) 9 refs

  14. Comparison of Solid and Hollow Torque Transducer Shaft Response in a High Alloy Stainless Steel

    Science.gov (United States)

    Milby, Christopher L.; Hecox, Bryan G.; Wiewel, Joseph L.; Boley, Mark S.

    2007-03-01

    Recent investigations of the torque transducer response function (ambient field signal versus applied torque or shear stress) have been conducted in a 13% chromium and 8% nickel stainless steel alloy in both the hollow shaft and solid shaft configuration. An understanding of both is needed for applications with differing yield strength and hardness requirements. Axial hysteresis measurements conducted before and after heat treatment exhibited little difference in coercivity and retentivity between the two sample types. However, the field mapping and transducer sensitivity studies showed the hollow shaft configuration to have a far superior degree of polarization in the sensory region and to exhibit an enhanced sensitivity, especially after heat treatment. This is most likely due to its more efficient provision of closed circumferential geometry for the field lines and improved grain alignment during heat treatment.

  15. Design of Stress-Strain Measuring System for Bulldozing Plate Based on Virtual Instrument Technology

    International Nuclear Information System (INIS)

    Xu, S C; Li, J Q; Zhang, R

    2006-01-01

    Soil is a kind of discrete, multiphase compound that is composed of soil particles, liquid and air. When soil is disturbed by bulldozing plate, the mechanical behavior of the soil will become very complex. Based on the law of action and reaction, the dynamic mechanical behavior of disturbed soil was indirectly analyzed by measuring and studying the forces on the bulldozing plate by soil currently, so a stress-strain virtual measuring system for bulldozing plate, which was designed by the graphical programming language DASYLab, was used to measure the horizontal force Fz acting on the bulldozing plate. In addition, during the course of design, the experimental complexities and the interferential factors influencing on signal logging were analyzed when bulldozing plate worked, so the anti-jamming methods of hardware and software technology were adopted correlatively. In the end, the horizontal force Fz was analyzed with Error Theory, the result shown that the quantificational analysis of Fz were identical to the qualitative results of soil well, and the error of the whole test system is under 5 percent, so the tress-strain virtual measuring system was stable and credible

  16. INFLUENCE OF COMPOUND DAM DESIGN ON ITS STRESS-STRAIN STATE

    Directory of Open Access Journals (Sweden)

    Sainov Mikhail Petrovich

    2018-02-01

    Full Text Available Subject: the dam of compound design in which the water pressure is borne mutually by a concrete gravity dam and a higher rockfill dam with reinforced concrete facing. Research objectives: 1 study the stress-strain state (SSS of a compound dam, identify the effect of three main factors on the dam SSS. The first factor is the height of the concrete structure. The second factor is the height of the contact zone (conjugation between the earth fill and the concrete structure. The third factor is deformability of riprap; 2 based on these studies, give recommendations for selection of the compound dam design. Materials and methods: SSS studies were conducted by numerical analysis using the finite element method (FEM. Nonlinear character of soils deformability and contacts of concrete structure with soils, foundation and reinforced concrete facing was taken into consideration. Sequence of the dam erection and loading was taken into account. Riprap’s modulus of deformation varied from 70 to 270 МPа. Results: results of the analysis showed that the concrete structure as a part of the compound dam withstands hydrostatic load almost independently, practically without transferring it to the earth fill. We have found out that the most sensitive part of the compound dam design is conjugation of the earth fill with the concrete structure. This zone is characterized by failures of the soil strength. The consequence of these failures are considerable displacements in the joint between the facing and the concrete structure as well as bending deformations of the lower part of the facing. Bending of the facing causes considerable tensile stresses. Conclusions: the results of studies permitted us to formulate the following recommendations: 1 it is not desirable to select the height of contact zone between the earth fill and the concrete structure more than 60-75 % of the concrete structure height because it leads to increase of loads borne by the concrete

  17. Respiratory Belt Transducer Constructed Using a Singing Greeting Card Beeper

    Science.gov (United States)

    Bhaskar, Anand; Subramani, Selvam; Ojha, Rajdeep

    2013-01-01

    An article by Belusic and Zupancic described the construction of a finger pulse sensor using a singing greeting card beeper. These authors felt that this beeper made of piezoelectric material could be easily modified to function as a respiratory belt transducer to monitor respiratory movements. Commercially available respiratory belt transducers,…

  18. Top-down tree transducers with regular look-ahead

    NARCIS (Netherlands)

    Engelfriet, Joost

    1977-01-01

    Top-down tree transducers with regular look-ahead are introduced. It is shown how these can be decomposed and composed, and how this leads to closure properties of surface sets and tree transformation languages. Particular attention is paid to deterministic tree transducers.

  19. A method for determining losses in magnetostrictive transducers

    Science.gov (United States)

    Krysin, V. N.; Ketlerov, A. S.

    A method for estimating energy losses in magnetostrictive transducers is described. It is shown that domain remagnetization is responsible for the greatest energy loss in magnetostrictive transducers. Energy losses associated with Foucault currents and Joule heat are an order of magnitude less.

  20. [The manufacture of the pressure transducer for medical Solos Insufflator].

    Science.gov (United States)

    Huang, X

    2001-07-01

    A 0-10 Kpa pressure transducer and its circuit are presented in the paper, which can be used as a substitute for the integrated pressure transducer in medical Solos Insufflator and can be used too in other devices and equipments.

  1. A rotary ultrasonic motor using bending vibration transducers.

    Science.gov (United States)

    Liu, Yingxiang; Chen, Weishan; Liu, Junkao; Shi, Shengjun

    2010-10-01

    A rotary ultrasonic motor using bending vibration transducers is proposed. In each transducer, two orthogonal bending vibrations are superimposed and an elliptical trajectory is generated at the driving foot. Typical output of the prototype is a no-load speed of 58 rpm and maximum torque of 9·5 Nm under an exciting voltage of 200 V(rms).

  2. Overexpression of thioredoxin in islets transduced by a lentiviral vector prolongs graft survival in autoimmune diabetic NOD mice

    Directory of Open Access Journals (Sweden)

    Sytwu Huey-Kang

    2009-08-01

    Full Text Available Abstract Pancreatic islet transplantation is considered an appropriate treatment to achieve insulin independence in type I diabetic patients. However, islet isolation and transplantation-induced oxidative stress and autoimmune-mediated destruction are still the major obstacles to the long-term survival of graft islets in this potential therapy. To protect islet grafts from inflammatory damage and prolong their survival, we transduced islets with an antioxidative gene thioredoxin (TRX using a lentiviral vector before transplantation. We hypothesized that the overexpression of TRX in islets would prolong islet graft survival when transplanted into diabetic non-obese diabetic (NOD mice. Methods Islets were isolated from NOD mice and transduced with lentivirus carrying TRX (Lt-TRX or enhanced green fluorescence protein (Lt-eGFP, respectively. Transduced islets were transplanted under the left kidney capsule of female diabetic NOD mice, and blood glucose concentration was monitored daily after transplantation. The histology of the islet graft was assessed at the end of the study. The protective effect of TRX on islets was investigated. Results The lentiviral vector effectively transduced islets without altering the glucose-stimulating insulin-secretory function of islets. Overexpression of TRX in islets reduced hydrogen peroxide-induced cytotoxicity in vitro. After transplantation into diabetic NOD mice, euglycemia was maintained for significantly longer in Lt-TRX-transduced islets than in Lt-eGFP-transduced islets; the mean graft survival was 18 vs. 6.5 days (n = 9 and 10, respectively, p Conclusion We successfully transduced the TRX gene into islets and demonstrated that these genetically modified grafts are resistant to inflammatory insult and survived longer in diabetic recipients. Our results further support the concept that the reactive oxygen species (ROS scavenger and antiapoptotic functions of TRX are critical to islet survival after

  3. Transducer hygiene: comparison of procedures for decontamination of ultrasound transducers and their use in clinical practice.

    Science.gov (United States)

    Häggström, Mikael; Spira, Jack; Edelstam, Greta

    2015-02-01

    To determine whether current hygiene practices are appropriate during sonographic examinations. Five major hospitals in Sweden were investigated with a survey. At each hospital, the departments corresponding to the main types of sonographic examination were chosen. Personnel who were responsible for or acquainted with the local hygiene procedures completed a standardardized questionnaire. The surveys were completed by 25 departments, where the total number of sonographic examinations was approximately 20,000 per month. For transvaginal and transrectal sonographic examinations, the most common method for decontamination of the transducer was barrier protection during the procedure followed by cleansing with alcohol. Latex was the predominant cover material, but one department used polyethylene gloves, and another department used nitrile gloves. Both of these involved transvaginal ultrasonography. In transcutaneous examinations, all hospitals were using alcohol and paper or cloth for decontamination at a minimum. Transesophageal examinations were carried out without barrier protection, and decontamination was performed with an alkylating substance. The hygiene practices appear to be appropriate at most hospitals, but there is a prevalence of transducer cover materials of unacceptable permeability, as well as use of gloves on transducers despite insufficient evidence of safety. © 2015 Wiley Periodicals, Inc.

  4. Design management and stress analysis of a circular rock tunnel and emplacement holes for storage of spent nuclear fuel

    International Nuclear Information System (INIS)

    Kandalaft-Ladkany, N.; Wyman, R.V.

    1992-01-01

    This paper discusses a critical path method (CPM) diagram and logic net which are used for the design cycle of the rock tunnel system for a high level nuclear waste repository. In the analysis the design tunnel is subjected to pre-existing temperature and overburden loads at time of construction. high thermal stresses develop later due to the long term influx of heat from the canisters stored in vertical emplacement holes. Results indicate that thermal stresses reach a critical level for the rock in the vicinity of the canisters which could lead to local collapse of the rock and damage to the canisters

  5. Stress.

    Science.gov (United States)

    Chambers, David W

    2008-01-01

    We all experience stress as a regular, and sometimes damaging and sometimes useful, part of our daily lives. In our normal ups and downs, we have our share of exhaustion, despondency, and outrage--matched with their corresponding positive moods. But burnout and workaholism are different. They are chronic, dysfunctional, self-reinforcing, life-shortening habits. Dentists, nurses, teachers, ministers, social workers, and entertainers are especially susceptible to burnout; not because they are hard-working professionals (they tend to be), but because they are caring perfectionists who share control for the success of what they do with others and perform under the scrutiny of their colleagues (they tend to). Workaholics are also trapped in self-sealing cycles, but the elements are ever-receding visions of control and using constant activity as a barrier against facing reality. This essay explores the symptoms, mechanisms, causes, and successful coping strategies for burnout and workaholism. It also takes a look at the general stress response on the physiological level and at some of the damage American society inflicts on itself.

  6. Numerical design and optimization of hydraulic resistance and wall shear stress inside pressure-driven microfluidic networks.

    Science.gov (United States)

    Damiri, Hazem Salim; Bardaweel, Hamzeh Khalid

    2015-11-07

    Microfluidic networks represent the milestone of microfluidic devices. Recent advancements in microfluidic technologies mandate complex designs where both hydraulic resistance and pressure drop across the microfluidic network are minimized, while wall shear stress is precisely mapped throughout the network. In this work, a combination of theoretical and modeling techniques is used to construct a microfluidic network that operates under minimum hydraulic resistance and minimum pressure drop while constraining wall shear stress throughout the network. The results show that in order to minimize the hydraulic resistance and pressure drop throughout the network while maintaining constant wall shear stress throughout the network, geometric and shape conditions related to the compactness and aspect ratio of the parent and daughter branches must be followed. Also, results suggest that while a "local" minimum hydraulic resistance can be achieved for a geometry with an arbitrary aspect ratio, a "global" minimum hydraulic resistance occurs only when the aspect ratio of that geometry is set to unity. Thus, it is concluded that square and equilateral triangular cross-sectional area microfluidic networks have the least resistance compared to all rectangular and isosceles triangular cross-sectional microfluidic networks, respectively. Precise control over wall shear stress through the bifurcations of the microfluidic network is demonstrated in this work. Three multi-generation microfluidic network designs are considered. In these three designs, wall shear stress in the microfluidic network is successfully kept constant, increased in the daughter-branch direction, or decreased in the daughter-branch direction, respectively. For the multi-generation microfluidic network with constant wall shear stress, the design guidelines presented in this work result in identical profiles of wall shear stresses not only within a single generation but also through all the generations of the

  7. Development of a high frequency single-element ultrasound needle transducer for anesthesia delivery

    Science.gov (United States)

    Ameri, Golafsoun; Son, Jungik; Liang, Jingwei; Foster, F. Stuart; Ganapathy, Sugantha; Peters, Terry M.

    2017-03-01

    Epidural anesthesia is one of the most commonly used and yet challenging techniques employed for pain management and anesthesia delivery. The major complications of this procedure are due to accidental dural puncture, with an incidence of 1-3%, which could lead to both temporary and irreversible permanent neurological complications. Needle placement under ultrasound (US) guidance has received increasing interest for improving needle placement accuracy. However, poor needle visibility in US, difficulties in displaying relevant anatomical structure such as dura mater due to attenuation and bone shadowing, and image interpretation variability among users pose significant hurdles for any US guidance system. As a result, US guidance for epidural injections has not been widely adopted for everyday use for the performance of neuraxial blocks. The difficulties in localizing the ligamentum flavum and dura with respect to the needle tip can be addressed by integrating A-mode US, provided by a single-element transducer at the needle tip, into the B-mode US guidance system. We have taken the first steps towards providing such a guidance system. Our goal is to improve the safety of this procedure with minimal changes to the clinical workflow. This work presents the design and development of a 20 MHz single-element US transducer housed at the tip of a 19 G needle hypodermic tube, which can fit inside an epidural introducer needle. In addition, the results from initial transducer characterization tests and performance evaluation of the transducer in a euthanized porcine model are provided.

  8. Anthropological and Psychological Merge: Design of a Stress Measure for Mexican Farmworkers

    OpenAIRE

    Snipes, Shedra A.; Thompson, Beti; O'Connor, Kathleen; Godina, Ruby; Ibarra, Genoveva

    2007-01-01

    This study implements qualitative and quantitative methodologies in the development of a culturally appropriate instrument of stress for Mexican immigrant farmworkers. Focus groups were used to uncover culturally based perspectives on life stressors, definitions of stress, and stress mediators. Qualitative data were analyzed using QSR NVivo and then used to develop a 23-item stress scale. The scale was tested for reliability and validity in an independent sample and demonstrates excellent rel...

  9. Resonant gravimetric immuno sensing based on capacitive micromachined ultrasound transducers

    International Nuclear Information System (INIS)

    Virzonis, Darius; Gailius Vanagas; Dovydas Barauskas; Ramanaviciene, Almira; Makaraviciute, Asta; Ramanavicius, Arunas; Wen, Weijia; Kodzius, Rimantas

    2014-01-01

    High-frequency (40 MHz) and low-frequency (7 MHz) capacitive micromachined ultrasound transducers (CMUT) were fabricated and tested for use in gravimetric detection of biomolecules. The low-frequency CMUT sensors have a gold-coated surface, while the high-frequency sensors have a silicon nitride surface. Both surfaces were functionalized with bovine leukemia virus antigen gp51 acting as the antigen. On addition of an a specific antibody labeled with horseradish peroxidase (HRP), the antigen/antibody complex is formed on the surface and quantified by HRP-catalyzed oxidation of tetramethylbenzidine. It has been found that a considerably smaller quantity of immuno complex is formed on the high frequency sensor surface. In parallel, the loading of the surface of the CMUT was determined via resonance frequency and electromechanical resistance readings. Following the formation of the immuno complexes, the resonance frequencies of the low-frequency and high-frequency sensors decrease by up to 420 and 440 kHz, respectively. Finite element analysis reveals that the loading of the (gold-coated) low frequency sensors is several times larger than that on high frequency sensors. The formation of the protein film with pronounced elasticity and stress on the gold surface case is discussed. We also discuss the adoption of this method for the detection of DNA using a hybridization assay following polymerase chain reaction. (author)

  10. Electromagnetic Acoustic Transducers for Robotic Nondestructive Inspection in Harsh Environments.

    Science.gov (United States)

    Choi, Sungho; Cho, Hwanjeong; Lindsey, Matthew S; Lissenden, Cliff J

    2018-01-11

    Elevated temperature, gamma radiation, and geometric constraints inside dry storage casks for spent nuclear fuel represent a harsh environment for nondestructive inspection of the cask and require that the inspection be conducted with a robotic system. Electromagnetic acoustic transducers (EMATs) using non-contact ultrasonic transduction based on the Lorentz force to excite/receive ultrasonic waves are suited for use in the robotic inspection. Periodic permanent magnet EMATs that actuate/receive shear horizontal guided waves are developed for application to robotic nondestructive inspection of stress corrosion cracks in the heat affected zone of welds in stainless steel dry storage canisters. The EMAT's components are carefully selected in consideration of the inspection environment, and tested under elevated temperature and gamma radiation doses up to 177 °C and 5920 krad, respectively, to evaluate the performance of the EMATs under realistic environmental conditions. The effect of gamma radiation is minimal, but the EMAT's performance is affected by temperatures above 121 °C due to the low Curie temperature of the magnets. Different magnets are needed to operate at 177 °C. The EMAT's capability to detect notches is also evaluated from B-scan measurements on 304 stainless steel welded plate containing surface-breaking notches.

  11. Resonant gravimetric immunosensing based on capacitive micromachined ultrasound transducers

    KAUST Repository

    Viržonis, Darius

    2014-04-08

    High-frequency (40 MHz) and low-frequency (7 MHz) capacitive micromachined ultrasound transducers (CMUT) were fabricated and tested for use in gravimetric detection of biomolecules. The low-frequency CMUT sensors have a gold-coated surface, while the high-frequency sensors have a silicon nitride surface. Both surfaces were functionalized with bovine leukemia virus antigen gp51 acting as the antigen. On addition of an a specific antibody labeled with horseradish peroxidase (HRP), the antigen/antibody complex is formed on the surface and quantified by HRP-catalyzed oxidation of tetramethylbenzidine. It has been found that a considerably smaller quantity of immuno complex is formed on the high frequency sensor surface. In parallel, the loading of the surface of the CMUT was determined via resonance frequency and electromechanical resistance readings. Following the formation of the immuno complexes, the resonance frequencies of the low-frequency and high-frequency sensors decrease by up to 420 and 440 kHz, respectively. Finite element analysis reveals that the loading of the (gold-coated) low frequency sensors is several times larger than that on high frequency sensors. The formation of the protein film with pronounced elasticity and stress on the gold surface case is discussed. We also discuss the adoption of this method for the detection of DNA using a hybridization assay following polymerase chain reaction.

  12. Renormalization Analysis of a Composite Ultrasonic Transducer with a Fractal Architecture

    Science.gov (United States)

    Algehyne, Ebrahem A.; Mulholland, Anthony J.

    To ensure the safe operation of many safety critical structures such as nuclear plants, aircraft and oil pipelines, non-destructive imaging is employed using piezoelectric ultrasonic transducers. These sensors typically operate at a single frequency due to the restrictions imposed on their resonant behavior by the use of a single length scale in the design. To allow these transducers to transmit and receive more complex signals it would seem logical to use a range of length scales in the design so that a wide range of resonating frequencies will result. In this paper, we derive a mathematical model to predict the dynamics of an ultrasound transducer that achieves this range of length scales by adopting a fractal architecture. In fact, the device is modeled as a graph where the nodes represent segments of the piezoelectric and polymer materials. The electrical and mechanical fields that are contained within this graph are then expressed in terms of a finite element basis. The structure of the resulting discretized equations yields to a renormalization methodology which is used to derive expressions for the non-dimensionalized electrical impedance and the transmission and reception sensitivities. A comparison with a standard design shows some benefits of these fractal designs.

  13. Three Dimensional Finite Element Analysis of Distal Abutment Stresses of Removable Partial Dentures with Different Retainer Designs

    Directory of Open Access Journals (Sweden)

    Simindokht Zarrati

    2015-11-01

    Full Text Available Objectives: This finite element method study aimed to compare the amount of stress on an isolated mandibular second premolar in two conventional reciprocal parallel interface designs of removable partial dentures (RPDs and the same RPD abutment tooth (not isolated.Materials and Methods: A Kennedy Class 1, modification 1 RPD framework was simulated on a 3D model of mandible with three different designs: an isolated tooth with a mesial rest, an isolated tooth with mesial and distal rests and an abutment with a mesial rest (which was not isolated; 26 N occlusal forces were exerted bilaterally on the first molar sites. Stress on the abutment teeth was analyzed using Cosmos Works 2009 Software.Results: In all designs, the abutment tooth stress concentration was located in the buccal alveolar crest. In the first model, the von Mises stress distribution in the contact area of I-bar clasp and cervical portion of the tooth was 19 MPa and the maximum stress was 30 MPa. In the second model, the maximum von Mises stress distribution was 15 MPa in the cervical of the tooth. In the third model, the maximum von Mises stress was located in the cervical of the tooth and the distal proximal plate.Conclusion: We recommend using both mesial and distal rests on the distal abutment teeth of distal extension RPDs. The abutment of an extension base RPD, which is not isolated in presence of its neighboring more anterior tooth, may have a better biomechanical prognosis.      

  14. The influence of various core designs on stress distribution in the veneered zirconia crown: a finite element analysis study

    OpenAIRE

    Ha, Seung-Ryong; Kim, Sung-Hun; Han, Jung-Suk; Yoo, Seung-Hyun; Jeong, Se-Chul; Lee, Jai-Bong; Yeo, In-Sung

    2013-01-01

    PURPOSE The purpose of this study was to evaluate various core designs on stress distribution within zirconia crowns. MATERIALS AND METHODS Three-dimensional finite element models, representing mandibular molars, comprising a prepared tooth, cement layer, zirconia core, and veneer porcelain were designed by computer software. The shoulder (1 mm in width) variations in core were incremental increases of 1 mm, 2 mm and 3 mm in proximal and lingual height, and buccal height respectively. To simu...

  15. Job stress, absenteeism and coronary heart disease European cooperative study (the JACE study): Design of a multicentre prospective study

    NARCIS (Netherlands)

    Houtman, I.; Kornitzer, M.; Smet, P. de; Koyuncu, R.; Backer, G. de; Pelfrene, E.; Romon, M.; Boulenguez, C.; Ferrario, M.; Origgi, G.; Sans, S.; Perez, I.; Wilhelmsen, L.; Rosengren, A.; Isacsson, S.-O.; Östergren, P.-O.

    1999-01-01

    Background: The motives, objectives and design of a multicentre prospective study on job stress, absenteeism and coronary heart disease in Europe (the JACE study) is presented in this paper. Some specific gaps in the reviewed literature are explicitly tapped into by the JACE study. Its objectives

  16. Conceptual development of a method to determine the principal stresses around coal mine workings to ensure safe mine design

    CSIR Research Space (South Africa)

    Coetzer, S

    1997-06-01

    Full Text Available The objective of this project is to identify or to develop methods or procedures for the determination of the principal stresses in coal mine workings, which in turn would provide improved criteria for mine design layouts in coal mines. To address...

  17. Influence of prosthesis design and implantation technique on implant stresses after cementless revision THR

    Directory of Open Access Journals (Sweden)

    Duda Georg N

    2011-05-01

    Full Text Available Abstract Background Femoral offset influences the forces at the hip and the implant stresses after revision THR. For extended bone defects, these forces may cause considerable bending moments within the implant, possibly leading to implant failure. This study investigates the influences of femoral anteversion and offset on stresses in the Wagner SL revision stem implant under varying extents of bone defect conditions. Methods Wagner SL revision stems with standard (34 mm and increased offset (44 mm were virtually implanted in a model femur with bone defects of variable extent (Paprosky I to IIIb. Variations in surgical technique were simulated by implanting the stems each at 4° or 14° of anteversion. Muscle and joint contact forces were applied to the reconstruction and implant stresses were determined using finite element analyses. Results Whilst increasing the implant's offset by 10 mm led to increased implant stresses (16.7% in peak tensile stresses, altering anteversion played a lesser role (5%. Generally, larger stresses were observed with reduced bone support: implant stresses increased by as much as 59% for a type IIIb defect. With increased offset, the maximum tensile stress was 225 MPa. Conclusion Although increased stresses were observed within the stem with larger offset and increased anteversion, these findings indicate that restoration of offset, key to restoring joint function, is unlikely to result in excessive implant stresses under routine activities if appropriate fixation can be achieved.

  18. Optimisation of Pulsed Ultrasonic Velocimetry system and transducer technology for industrial applications.

    Science.gov (United States)

    Kotzé, Reinhardt; Wiklund, Johan; Haldenwang, Rainer

    2013-02-01

    Pulsed Ultrasonic Velocimetry, commonly referred to as Ultrasonic Velocity Profiling (UVP) in research and engineering applications, is both a method and a device to measure an instantaneous one-dimensional velocity profile in opaque fluids along a measurement axis by using Doppler echography. Studies have suggested that the accuracy of the measured velocity gradient close to wall interfaces need to be improved. The reason for this is due to distortion caused by cavities situated in front of ultrasonic transducers, measurement volumes overlapping wall interfaces, refraction of the ultrasonic wave as well as sound velocity variations (Doppler angle changes). In order to increase the accuracy of velocity data close to wall interfaces and solve previous problems a specially designed delay line transducer was acoustically characterised and evaluated. Velocity profiles measured using the delay line transducer, were initially distorted due to the effect of finite sample volume characteristics and propagation through the delay line material boundary layers. These negative effects were overcome by measuring physical properties of the ultrasonic beam and implementing a newly developed deconvolution procedure. Furthermore, custom velocity estimation algorithms were developed, which improved the time resolution and penetration depth of the UVP system. The optimised UVP system was evaluated and compared to standard transducers in three different straight pipes (inner diameters of 16, 22.5 and 52.8mm). Velocity data obtained using the optimised UVP system showed significant improvement close to wall interfaces where the velocity gradients are high. The new transducer technology and signal processing techniques reduced previously mentioned problems and are now more suitable for industrial process monitoring and control. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Dynamic calibration of pressure transducers with an improved shock tube system

    Science.gov (United States)

    Wisniewiski, David

    2013-04-01

    The need for reliable dynamic calibration of pressure transducers is becoming increasingly more important, especially with growing demands for improved performance, increased reliability and efficient energy generation from the aerospace, defense and energy sectors - all while being mindful of low lifecycle cost, minimizing maintenance downtime and reducing any negative impact to the environment. State of the art piezoelectric (PE) and piezoresistive (PR) silicon MEMS pressure transducers specifically designed for harsh environments are answering the call to provide the necessary measurements for applications such as high temperature gas turbine engine health monitoring (both in-flight and land/marine based aero-derivative), high pressure blast studies/ordnance explosion optimization, low profile wind tunnel testing/flight testing, etc. However, these pressure transducers are only as valuable as the dynamic calibration they possess so that more understanding of the physical measurement can be ascertained by the end-user. The shock tube is an established laboratory tool capable of imparting near instantaneous pressure stimulus for the purpose of providing quantifiable dynamic calibration of pressure transducers. From a performance perspective, a vast amount of empirical data has been collected over fifteen years and used to model more accurately the one-dimensional gas dynamics occurring within a shock tube so that the time interval of the reflected shock - the most critical parameter in determining the transfer function for the pressure transducer under test - can be optimized for the largest frequency bandwidth over varying shock amplitudes. Accordingly, an introduction of an improved shock tube system offering both increased performance and ease of user operation is presented.

  20. Performance Improvement of High Frequency Aluminum Nitride Ultrasonic Transducers

    Directory of Open Access Journals (Sweden)

    Yangjie Wei

    2013-01-01

    Full Text Available This paper presents three methods to improve the performance of a high frequency aluminum nitride (AlN ultrasonic transducer. For a high frequency AlN ultrasonic transducer, its properties are related with its top electrode size, electrical impedance matching and layers of the piezoelectric plate. However, until now, no research has been published to analyze their influence on the performance of AlN ultrasonic transducers, especially in the frequency range above 200 MHz. First, two factors related with the top electrode size are proposed based on transmission coefficient and stored energy, and analysis is performed on an Al-AlN-Al on silicon wafers with different electrode sizes. The result proves when the electrode size is 1mm2, the transducer can provide the maximum output voltage and the maximal signal- to-noise ratio (SNR. Then, electrical impedance matching is conducted to improve the performance of transducers, and the experiment result shows that after matching, the resolution and sensitivity have been improved. Finally, a stacked AlN transducer is developed and its model is constructed to analyze its properties in time domain and frequency domain. The comparison between the simulation and the experiment shows the effectiveness of the proposed model, and a stacked structure can be used to improve the sensitivity of a high frequency AlN ultrasonic transducer.

  1. Piezoelectric Nanotube Array for Broadband High-Frequency Ultrasonic Transducer.

    Science.gov (United States)

    Liew, Weng Heng; Yao, Kui; Chen, Shuting; Tay, Francis Eng Hock

    2018-03-01

    Piezoelectric materials are vital in determining ultrasonic transducer and imaging performance as they offer the function for conversion between mechanical and electrical energy. Ultrasonic transducers with high-frequency operation suffer from performance degradation and fabrication difficulty of the demanded piezoelectric materials. Hence, we propose 1-D polymeric piezoelectric nanostructure with controlled nanoscale features to overcome the technical limitations of high-frequency ultrasonic transducers. For the first time, we demonstrate the integration of a well-aligned piezoelectric nanotube array to produce a high-frequency ultrasonic transducer with outstanding performance. We find that nanoconfinement-induced polarization orientation and unique nanotube structure lead to significantly improved piezoelectric and ultrasonic transducing performance over the conventional piezoelectric thin film. A large bandwidth, 126% (-6 dB), is achieved at high center frequency, 108 MHz. Transmission sensitivity of nanotube array is found to be 46% higher than that of the monolithic thin film transducer attributed to the improved electromechanical coupling effectiveness and impedance match. We further demonstrate high-resolution scanning, ultrasonic imaging, and photoacoustic imaging using the obtained nanotube array transducers, which is valuable for biomedical imaging applications in the future.

  2. Research of aluminum alloys with using eddy-current transducers on the basis of cores of various form

    Science.gov (United States)

    Dmitriev, S. F.; Ishkov, A. V.; Katasonov, A. O.; Malikov, V. N.; Sagalakov, A. M.

    2018-01-01

    The research aims to develop a microminiature eddy current transducer for aluminum alloys. The research topic is considered relevant due to the need for evaluation and forecasting of safe operating life of aluminum. A microminiature transformer-type transducer was designed, which enables to perform local investigations of unferromagnetic materials using eddy-current method based on local studies conductivity. Having the designed transducer as a basis, a hardware-software complex was built to perform experimental studies of aluminium. Cores with different shapes were used in this work. Test results are reported for a flaws in the form of hidden slits and apertures inside the slabs is derived for excitation coil frequencies of 300–700 Hz.

  3. Bio-applications of ionic polymer metal composite transducers

    International Nuclear Information System (INIS)

    Aw, K C; McDaid, A J

    2014-01-01

    Traditional robotic actuators have advanced performance which in some aspects can surpass that of humans, however they are lacking when it comes to developing devices which are capable of operating together with humans. Bio-inspired transducers, for example ionic polymer metal composites (IPMC), which have similar properties to human tissue and muscle, demonstrate much future promise as candidates for replacing traditional robotic actuators in medical robotics applications. This paper outlines four biomedical robotics applications, an IPMC stepper motor, an assistive glove exoskeleton/prosthetic hand, a surgical robotic tool and a micromanipulation system. These applications have been developed using mechanical design/modelling techniques with IPMC ‘artificial muscle’ as the actuation system. The systems are designed by first simulating the performance using an IPMC model and dynamic models of the mechanical system; the appropriate advanced adaptive control schemes are then implemented to ensure that the IPMCs operate in the correct manner, robustly over time. This paper serves as an overview of the applications and concludes with some discussion on the future challenges of developing real-world IPMC applications

  4. Two-stage SQUID system and transducers development for MiniGrail

    NARCIS (Netherlands)

    Gottardi, L.; Podt, M.; Flokstra, Jakob; Bassan, M.; Karbalai-Sadegh, A.; Minenkov, Y.; Reinke, W.; Shumack, A.; Srinivas, S.; de Waard, A.; de Waard, A.; Frossati, G.

    2004-01-01

    We present measurements on a two-stage SQUID system based on a dc-SQUID as a sensor and a DROS as an amplifier. We measured the intrinsic noise of the dc-SQUID at 4.2 K. A new dc-SQUID has been fabricated. It was specially designed to be used with MiniGRAIL transducers. Cooling fins have been added

  5. Transducer-based fiber Bragg grating high-temperature sensor with enhanced range and stability

    Science.gov (United States)

    Mamidi, Venkata Reddy; Kamineni, Srimannarayana; Ravinuthala, Lakshmi Narayana Sai Prasad; Tumu, Venkatappa Rao

    2017-09-01

    Fiber Bragg grating (FBG)-based high-temperature sensor with enhanced-temperature range and stability has been developed and tested. The sensor consists of an FBG and a mechanical transducer, which furnishes a linear temperature-dependent tensile strain on FBG by means of differential linear thermal expansion of two different ceramic materials. The designed sensor is tested over a range: 20°C to 1160°C and is expected to measure up to 1500°C.

  6. Stress analysis and fail-safe design of bilayered tubular supported ceramic membranes

    DEFF Research Database (Denmark)

    Kwok, Kawai; Frandsen, Henrik Lund; Søgaard, Martin

    2014-01-01

    Supported ceramic membranes based on mixed ionic and electronic conductors are a promising technology for oxygen separation applications. In addition to chemically induced stress under oxygen activity gradients in the materials, strain mismatch between membrane and support gives rise...... to considerable stress that may compromise mechanical reliability. This paper presents an analysis of stress generated in tubular supported membranes during operation. Closed-form analytical solutions for stresses due to external pressures, strain gradients, and mismatch in materials properties are derived....... Stress distributions in two membrane systems have been analyzed and routes to minimize stress are proposed. For a Ba0.5Sr0.5Co0.8Fe0.2O3−δBa0.5Sr0.5Co0.8Fe0.2O3−δ membrane supported on a porous substrate of the same material under pressure-vacuum operation, the optimal configuration in terms...

  7. Mechanical stress induces biotic and abiotic stress responses via a novel cis-element.

    Directory of Open Access Journals (Sweden)

    Justin W Walley

    2007-10-01

    Full Text Available Plants are continuously exposed to a myriad of abiotic and biotic stresses. However, the molecular mechanisms by which these stress signals are perceived and transduced are poorly understood. To begin to identify primary stress signal transduction components, we have focused on genes that respond rapidly (within 5 min to stress signals. Because it has been hypothesized that detection of physical stress is a mechanism common to mounting a response against a broad range of environmental stresses, we have utilized mechanical wounding as the stress stimulus and performed whole genome microarray analysis of Arabidopsis thaliana leaf tissue. This led to the identification of a number of rapid wound responsive (RWR genes. Comparison of RWR genes with published abiotic and biotic stress microarray datasets demonstrates a large overlap across a wide range of environmental stresses. Interestingly, RWR genes also exhibit a striking level and pattern of circadian regulation, with induced and repressed genes displaying antiphasic rhythms. Using bioinformatic analysis, we identified a novel motif overrepresented in the promoters of RWR genes, herein designated as the Rapid Stress Response Element (RSRE. We demonstrate in transgenic plants that multimerized RSREs are sufficient to confer a rapid response to both biotic and abiotic stresses in vivo, thereby establishing the functional involvement of this motif in primary transcriptional stress responses. Collectively, our data provide evidence for a novel cis-element that is distributed across the promoters of an array of diverse stress-responsive genes, poised to respond immediately and coordinately to stress signals. This structure suggests that plants may have a transcriptional network resembling the general stress signaling pathway in yeast and that the RSRE element may provide the key to this coordinate regulation.

  8. USE OF PELTIER COOLERS AS SOIL HEAT FLUX TRANSDUCERS.

    Science.gov (United States)

    Weaver, H.L.; Campbell, G.S.

    1985-01-01

    Peltier coolers were modified and calibrated to serve as soil heat flux transducers. The modification was to fill their interiors with epoxy. The average calibration constant on 21 units was 13. 6 plus or minus 0. 8 kW m** minus **2 V** minus **1 at 20 degree C. This sensitivity is about eight times that of the two thermopile transducers with which comparisons were made. The thermal conductivity of the Peltier cooler transducers was 0. 4 W m** minus **1 degree C** minus **1, which is comparable to that of dry soil.

  9. Ultrasonic Transducer Peak-to-Peak Optical Measurement

    Directory of Open Access Journals (Sweden)

    Pavel Skarvada

    2012-01-01

    Full Text Available Possible optical setups for measurement of the peak-to-peak value of an ultrasonic transducer are described in this work. The Michelson interferometer with the calibrated nanopositioner in reference path and laser Doppler vibrometer were used for the basic measurement of vibration displacement. Langevin type of ultrasonic transducer is used for the purposes of Electro-Ultrasonic Nonlinear Spectroscopy (EUNS. Parameters of produced mechanical vibration have to been well known for EUNS. Moreover, a monitoring of mechanical vibration frequency shift with a mass load and sample-transducer coupling is important for EUNS measurement.

  10. Mechanosensitive control of plant growth: Bearing the load, sensing, transducing and responding

    Directory of Open Access Journals (Sweden)

    Bruno eMoulia

    2015-02-01

    Full Text Available As land plants grow and develop, they encounter complex mechanical challenges, especially from winds and turgor pressure. Mechanosensitive control over growth and morphogenesis is an adaptive trait, reducing the risks of breakage or explosion. This control has been mostly studied through experiments with artificial mechanical loads, often focusing on cellular or molecular mechanotransduction pathway. However some important aspects of mechanosensing are often neglected. i What are the mechanical characteristics of different loads and how are loads distributed within different organs? ii What is the relevant mechanical stimulus in the cell? Is it stress, strain, or energy? iii How do mechanosensing cells signal to meristematic cells? Without answers to these questions we cannot make progress analyzing the mechanobiological effects of plant size, plant shape, tissue distribution and stiffness, or the magnitude of stimuli. This situation is rapidly changing however, as systems mechanobiology is being developed, using specific biomechanical and/or mechanobiological models. These models are instrumental in comparing loads and responses between experiments and make it possible to quantitatively test biological hypotheses describing the mechanotransduction networks. This review is designed for a general plant science audience and aims to help biologists master the models they need for mechanobiological studies. Analysis and modeling is broken down into four steps looking at how the structure bears the load, how the distributed load is sensed, how the mechanical signal is transduced, and then how the plant responds through growth. Throughout, two examples of adaptive responses are used to illustrate this approach: the thigmorphogenetic syndrome of plant shoots bending and the mechanosensitive control of shoot apical meristem morphogenesis. Overall this should provide a generic understanding of systems mechanobiology at work.

  11. Comparison of transducers with different frequencies in breast contrast-enhanced ultrasound (CEUS) using SonoVue as contrast agent.

    Science.gov (United States)

    Wang, Yong-Mei; Fan, Wei; Zhang, Kai; Zhang, Li; Tan, Zhen; Ma, Rong

    2016-07-01

    To explore the effectiveness of different transducers in breast contrast-enhanced ultrasound (CEUS) using SonoVue(®) (Bracco, Plan-Les-Ouates, Switzerland) as the contrast agent. Breast CEUS was performed in 51 patients with 51 breast lesions using a low-frequency transducer (probe C5-1) and a high-frequency transducer (probe L12-5) separately. All image processes were reviewed for the presence of local blood perfusion defects and surrounding vessels. McNemar's test was conducted to compare the detection effectiveness between these two transducers. Pathological results revealed 38 malignant and 13 benign lesions. The two transducers showed no difference in detecting benign lesions. Among malignant lesions, CEUS conducted by probe C5-1 (frequency range from 1 to 5 MHz) presented 23 (60.5%) lesions with local blood perfusion defects and 26 (68.4%) lesions with surrounding vessels. Meanwhile, probe L12-5 (frequency range from 5 to 12 MHz) showed only 12 (31.6%) lesions with local blood perfusion defects and 12 (31.6%) lesions with surrounding vessel. Probe C5-1 was more sensitive than probe L12-5 in detecting malignant CEUS characteristics (p-value SonoVue as the contrast agent. A new contrast agent with a higher resonance frequency, specially designed for high-frequency transducers, may be helpful in improving the clinical value of breast CEUS. The first study comparing different frequency transducers in breast CEUS of the same patient lesions. We brought out the requirement for CEUS contrast agents which are more suitable for high-frequency examinations.

  12. Designing the fiber volume ratio in SiC fiber-reinforced SiC ceramic composites under Hertzian stress

    International Nuclear Information System (INIS)

    Lee, Kee Sung; Jang, Kyung Soon; Park, Jae Hong; Kim, Tae Woo; Han, In Sub; Woo, Sang Kuk

    2011-01-01

    Highlights: → Optimum fiber volume ratios in the SiC/SiC composite layers were designed under Hertzian stress. → FEM analysis and spherical indentation experiments were undertaken. → Boron nitride-pyrocarbon double coatings on the SiC fiber were effective. → Fiber volume ratio should be designed against flexural stress. -- Abstract: Finite element method (FEM) analysis and experimental studies are undertaken on the design of the fiber volume ratio in silicon carbide (SiC) fiber-reinforced SiC composites under indentation contact stresses. Boron nitride (BN)/Pyrocarbon (PyC) are selected as the coating materials for the SiC fiber. Various SiC matrix/coating/fiber/coating/matrix structures are modeled by introducing a woven fiber layer in the SiC matrix. Especially, this study attempts to find the optimum fiber volume ratio in SiC fiber-reinforced SiC ceramics under Hertzian stress. The analysis is performed by changing the fiber type, fiber volume ratio, coating material, number of coating layers, and stacking sequence of the coating layers. The variation in the stress for composites in relation to the fiber volume ratio in the contact axial or radial direction is also analyzed. The same structures are fabricated experimentally by a hot process, and the mechanical behaviors regarding the load-displacement are evaluated using the Hertzian indentation method. Various SiC matrix/coating/fiber/coating/matrix structures are fabricated, and mechanical characterization is performed by changing the coating layer, according to the introduction (or omission) of the coating layer, and the number of woven fiber mats. The results show that the damage mode changes from Hertzian stress to flexural stress as the fiber volume ratio increases in composites because of the decreased matrix volume fraction, which intensifies the radial crack damage. The result significantly indicates that the optimum fiber volume ratio in SiC fiber-reinforced SiC ceramics should be designed for

  13. 77 FR 70124 - Policy Statement on the Scenario Design Framework for Stress Testing

    Science.gov (United States)

    2012-11-23

    ... testing that would be used in connection with the supervisory and company-run stress tests conducted under... Policy and Research. SUPPLEMENTARY INFORMATION: Table of Contents I. Background II. Administrative Law... of stress testing as a means to better understand the range of a banking organization's potential...

  14. Academic stress in master’s students and its modulatory variables: a between-groups design

    Directory of Open Access Journals (Sweden)

    Arturo Barraza Macías

    2009-10-01

    Full Text Available The present investigation tries to establish the descriptive profile of the academic stress of the students of the masters in education and to identify which sociodemographic and situational variables play a modulator role. This investigation is based on the Person-Surroundings Research Program and the systemical cognitive model of academic stress. The study can be characterized as transectional, correlational and non experimental. The collection of the information was made through the SISCO inventory of Academic Stress which was applied to 152 students. The main results suggest that 95% of the master students report having felt academic stress a few times but with medium-high intensity. Variables gender, civil state, attending masters and institutional support of the attending masters act as modulators in academic stress.

  15. Active Metamaterial Based Ultrasonic Guided Wave Transducer System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — An active and tunable metamaterial phased array transducer for guided wave mode selection with high intensity per driving channel and with dramatically lower modal...

  16. Spatial impulse response of a rectangular double curved transducer

    DEFF Research Database (Denmark)

    Bæk, David; Jensen, Jørgen Arendt; Willatzen, Morten

    2012-01-01

    Calculation of the pressure field from transducers having both a convex and a concave surface geometry is a complicated assignment that often is accomplished by subdividing the transducer surface into smaller flat elements of which the spatial impulse response is known. This method is often seen...... applied to curved transducers because an analytical solution is un-known. In this work a semi-analytical algorithm for the exact solution to a first order in diffraction effect of the spatial impulse response of rectangular shaped double curved transducers is presented. The algorithm and an approximation...... approximations ranging from 0.03 % to 0.8 % relative to a numerical solution for the spatial impulse response. It is shown that the presented algorithm gives consistent results with Field II for a linear flat, a linear focused, and a convex non-focused element. Best solution was found to be 0.01 % with a three...

  17. Wideband Single Crystal Transducer for Bone Characterization, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — TRS proposes to develop a simple-to-use, launch capable, ultrasound transducer that is capable of producing the necessary bandwidth to accurately determine in vivo...

  18. Acoustical imaging using capacitive micromachined ultrasonic transducer arrays: Devices, circuits, and systems

    Science.gov (United States)

    Oralkan, Omer

    Integrated circuit technologies have had a great impact on the development of medical devices. Diagnostic imaging systems have benefited tremendously from the improvements in integrated circuits. One of the recent examples of this interaction between the two disciplines occurred in the area of ultrasonic imaging. The ability to build structures with dimensions in the submicron range enabled the realization of an almost a century old idea: Capacitive ultrasonic transducers. The major advantages of this transducer technology are ease of fabrication, potential for integration with supporting electronic circuits and improved bandwidth and sensitivity. This dissertation analyzes the viability of capacitive micromachined ultrasonic transducers (CMUTs) for practical imaging applications. This analysis is conducted by a detailed characterization effort, and by demonstrating both 2-D and 3-D images. Acoustical performance of 1-D and 2-D CMUT arrays fabricated using silicon integrated circuit technology has been experimentally characterized for transmit and receive modes, and the results are found to be in good agreement with the theoretical expectations. Both 2-D and 3-D images have been demonstrated. The distinctive features of CMUTs manifest themselves in the results of the characterization experiments and also in the resulting images. This dissertation also describes a general approach to design integrated front-end circuits for ultrasonic imaging and demonstrates basic circuit blocks for use in integrated systems along with CMUT arrays. The integration of the ultrasonic transducer arrays with supporting electronics not only reduces the cost and complexity of the system but also provides several advantages such as reduced parasitics, improved sensitivity, and a compact design with a reduced number of external interconnects. In this study, a custom integrated circuit comprising a pulse driver, a transmit/receive (T/R) switch and a wideband preamplifier has been fabricated

  19. Polymerization Stress Development in Dental Composites: Effect of Cavity Design Factor

    Directory of Open Access Journals (Sweden)

    Drago Skrtic

    2009-03-01

    Full Text Available The objective of the study was to assess the effect of the cavity design factor (C-factor on polymerization stress development (PSD in resin composites. An experimental resin (BT resin was prepared, which contained 2,2-bis[p-(2’-hydroxy-3’-methacryloxypropoxyphenylene]propane (B and triethylene glycol dimethacrylate (T in 1:1 mass ratio, and an activator for visible light polymerization. An experimental composite with demonstrated remineralizing potential was also formulated by inclusion into the BT resin of zirconia-hybridized amorphous calcium phosphate (ACP filler at a mass fraction of 40 % (BT/ACP composite. A commercial glass-filled composite (TPH was used as a control. To assess the effect of the test geometry on PSD, C-factor was systematically varied between 0.8 and 6.0 by varying the height of the cylindrical composite specimens. The measured PSD values obtained by cantilever beam tensometry for specimens with variable C-factors were normalized for mass to specimens with a C-factor of 1.33 (h=2.25 mm as controls to give calculated PSD values. Degrees of vinyl conversions (DC attained in the TPH control and in the experimental BT/ACP composites were measured by near-infrared spectroscopy. In both the TPH and BT/ACP composite series, PSDcalc increased with the increasing C-factor, confirming the hypothesis that the C-factor value influences PSD values. The higher PSDmeas and PSDcalc values for the experimental BT/ACP composite compared to the commercial TPH composite probably reflect differences in the type and mass of the resin and filler phases in the two types of composite. These differences also account for the observed variation (21 % in DC attained in a BT/ACP composite 2 h after cure (69.5 % and in the DC of the TPH composite (57.5 % having the same C-factor. The cavity design factor seems to play a key role in influencing the PSD of bonded composites, but other factors such as composite mass and composition also must be

  20. Finite-State Complexity and the Size of Transducers

    Directory of Open Access Journals (Sweden)

    Cristian Calude

    2010-08-01

    Full Text Available Finite-state complexity is a variant of algorithmic information theory obtained by replacing Turing machines with finite transducers. We consider the state-size of transducers needed for minimal descriptions of arbitrary strings and, as our main result, we show that the state-size hierarchy with respect to a standard encoding is infinite. We consider also hierarchies yielded by more general computable encodings.

  1. Creep-Fatigue Life Design with Various Stress and Temperature Conditions on the Basis of Lethargy Coefficient

    International Nuclear Information System (INIS)

    Park, Jung Eun; Yang, Sung Mo; Han, Jae Hee; Yu, Hyo Sun

    2011-01-01

    High temperature and stress are encounted in power plants and vehicle engines. Therefore, determination of the creep-fatigue life of a material is necessary prior to fabricating equipment. In this study, life design was determined on the basis of the lethargy coefficient for different temperatures, stress and rupture times. SP-Creep test data was compared with computed data. The SP-Creep test was performed to obtain the rupture time for X20CrMoV121 steel. The integration life equation was considered for three cases with various load, temperature and load-temperature. First, the lethargy coefficient was calculated by using the obtained rupture stress and the rupture time that were determined by carrying out the SP-Creep test. Next, life was predicted on the basis of the temperature condition. Finally, it was observed that life decreases considerably due to the coupling effect that results when fatigue and creep occur simultaneously

  2. A novel robotic arm driven by sandwich piezoelectric transducers.

    Science.gov (United States)

    Jiang, Zheng; Wang, Liang; Jin, Jiamei

    2018-03-01

    In this work, a novel robotic arm driven by sandwich piezoelectric transducers is proposed. The proposed robotic arm is composed of three arms and four joints. Each arm consists of a sandwich piezoelectric transducer and an H-shaped hollow frame. The sandwich piezoelectric transducer utilizes frictional force to drive the joints on its both sides to rotate simultaneously. The joint between two arms can be driven to rotate in two perpendicular directions by two sandwich piezoelectric transducers. The rotation of joints results in the arm motion. Utilizing the finite element method, the optimized geometrical parameters of the sandwiched piezoelectric transducer are obtained, and the operating principle is demonstrated. A prototype of the robotic arm is also fabricated and assembled, it is 573 g in weight and 412 mm in length, and the maximum rotation angle of each joint is 160°. The mechanical characteristics of the robotic arm prototype are investigated by experiments. The results indicate that, when the excitation frequency of one sandwich piezoelectric transducer is 37.4 kHz, the arms on its two sides rotate in opposite directions with an average rotational velocity of 320 deg/s at 330 V pp , a resolution of 100 μrad at 230 V pp , and a startup and shutdown response time of 40 ms and 30 ms at 230 V pp , respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. High Frequency Longitudinal Damped Vibrations of a Cylindrical Ultrasonic Transducer

    Directory of Open Access Journals (Sweden)

    Mihai Valentin Predoi

    2014-01-01

    Full Text Available Ultrasonic piezoelectric transducers used in classical nondestructive testing are producing in general longitudinal vibrations in the MHz range. A simple mechanical model of these transducers would be very useful for wave propagation numerical simulations, avoiding the existing complicated models in which the real components of the transducer are modeled by finite elements. The classical model for longitudinal vibrations is not adequate because the generated longitudinal wave is not dispersive, the velocity being the same at any frequency. We have adopted the Rayleigh-Bishop model, which avoids these limitations, even if it is not converging to the first but to the second exact longitudinal mode in an elastic rod, as obtained from the complicated Pochhammer-Chree equations. Since real transducers have significant vibrations damping, we have introduced a damping term in the Rayleigh-Bishop model, increasing the imaginary part and keeping almost identical real part of the wavenumber. Common transducers produce amplitude modulated signals, completely attenuated after several periods. This can be modeled by two close frequencies, producing a “beat” phenomenon, superposed on the high damping. For this reason, we introduce a two-rod Rayleigh-Bishop model with damping. Agreement with measured normal velocity on the transducer free surface is encouraging for continuation of the research.

  4. Receive-Noise Analysis of Capacitive Micromachined Ultrasonic Transducers.

    Science.gov (United States)

    Bozkurt, Ayhan; Yaralioglu, G Goksenin

    2016-11-01

    This paper presents an analysis of thermal (Johnson) noise received from the radiation medium by otherwise noiseless capacitive micromachined ultrasonic transducer (CMUT) membranes operating in their fundamental resonance mode. Determination of thermal noise received by multiple numbers of transducers or a transducer array requires the assessment of cross-coupling through the radiation medium, as well as the self-radiation impedance of the individual transducer. We show that the total thermal noise received by the cells of a CMUT has insignificant correlation, and is independent of the radiation impedance, but is only determined by the mass of each membrane and the electromechanical transformer ratio. The proof is based on the analytical derivations for a simple transducer with two cells, and extended to transducers with numerous cells using circuit simulators. We used a first-order model, which incorporates the fundamental resonance of the CMUT. Noise power is calculated by integrating over the entire spectrum; hence, the presented figures are an upper bound for the noise. The presented analyses are valid for a transimpedance amplifier in the receive path. We use the analysis results to calculate the minimum detectable pressure of a CMUT. We also provide an analysis based on the experimental data to show that output noise power is limited by and comparable to the theoretical upper limit.

  5. Software for Correcting the Dynamic Error of Force Transducers

    Directory of Open Access Journals (Sweden)

    Naoki Miyashita

    2014-07-01

    Full Text Available Software which corrects the dynamic error of force transducers in impact force measurements using their own output signal has been developed. The software corrects the output waveform of the transducers using the output waveform itself, estimates its uncertainty and displays the results. In the experiment, the dynamic error of three transducers of the same model are evaluated using the Levitation Mass Method (LMM, in which the impact forces applied to the transducers are accurately determined as the inertial force of the moving part of the aerostatic linear bearing. The parameters for correcting the dynamic error are determined from the results of one set of impact measurements of one transducer. Then, the validity of the obtained parameters is evaluated using the results of the other sets of measurements of all the three transducers. The uncertainties in the uncorrected force and those in the corrected force are also estimated. If manufacturers determine the correction parameters for each model using the proposed method, and provide the software with the parameters corresponding to each model, then users can obtain the waveform corrected against dynamic error and its uncertainty. The present status and the future prospects of the developed software are discussed in this paper.

  6. Damage detection in concrete structures with smart piezoceramic transducers

    Science.gov (United States)

    Naidu, Akshay S. K.; Bhalla, Suresh

    2003-10-01

    Detection of damages and progressive deterioration in structures is a critical issue. Visual inspections are tedious and unreliable. Incipient damages are often not discernible by low frequency dynamic response and other NDE techniques. Smart piezoelectric ceramic (PZT) transducers are emerging as an effective alternative in health monitoring of structures. The electro-mechanical impedance method employs the self-actuating and sensing characteristics of the PZT, without having to use actuators and sensors separately. When excited by an ac source, the PZT transducers bonded to the host structure activates the higher modes of vibration locally. Changes in the admittance response of the transducer serves as an indicator of damage around the transducer. In this paper, the effectiveness of PZT transducers for characterizing damages in concrete, in terms of the damage extent and location, is experimentally examined. The root mean square deviation (RMSD) index, adopted to quantify the changes in the admittance signatures, correlates with the damage extent. The damages on the surface that is not mounted by the PZT are also discernible. An array of transducers proves effective in detecting the damaged zone. The progressive incipient crack can be detected much before it actually becomes visible to the naked eye.

  7. Damage Identification of Wind Turbine Blades Using Piezoelectric Transducers

    Directory of Open Access Journals (Sweden)

    Seong-Won Choi

    2014-01-01

    Full Text Available This paper presents the experimental results of active-sensing structural health monitoring (SHM techniques, which utilize piezoelectric transducers as sensors and actuators, for determining the structural integrity of wind turbine blades. Specifically, Lamb wave propagations and frequency response functions at high frequency ranges are used to estimate the condition of wind turbine blades. For experiments, a 1 m section of a CX-100 blade is used. The goal of this study is to assess and compare the performance of each method in identifying incipient damage with a consideration given to field deployability. Overall, these methods yielded a sufficient damage detection capability to warrant further investigation. This paper also summarizes the SHM results of a full-scale fatigue test of a 9 m CX-100 blade using piezoelectric active sensors. This paper outlines considerations needed to design such SHM systems, experimental procedures and results, and additional issues that can be used as guidelines for future investigations.

  8. Development of capacitive micromachined ultrasonic transducer for noncontact ultrasonic detection

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Bok; Ahn, Bong Young; Park, Hae Won; Kim, Young Joo; Lee, Seung Seok [Center for Environment and Safrty Measurement, KRISS, Daejeon (Korea, Republic of)

    2004-11-15

    In this study, the capacitive micromachined ultrasonic transducer (cMUT) was developed. Theoretical analysis and finite element analysis of the behavior of membrane (such as resonance frequency, membrane deflection, collapse deflection and collapse voltage) of the cMUT were performed. The design parameters of the cMUT were estimated and are the dimension and thickness of membrane, thickness of sacrificial layer, thickness and size of electrode, size of active element and so on. With the micro-fabrication process, the cMUT was fabricated on the silicon wafer. To measure the membrane displacement of cMUT, the Michelson phase modulation fiber interferometer was constructed. The measured membrane displacement was good agreed with the result of finite element analysis. To estimate the ultrasonic wave generated by the cMUT, the ultrasonic transceiver system was constructed. The developed cMUT shows a good performance and hence will be widely used to the filed of non-contact ultrasonic application.

  9. Development of capacitive micromachined ultrasonic transducer for noncontact ultrasonic detection

    International Nuclear Information System (INIS)

    Kim, Ki Bok; Ahn, Bong Young; Park, Hae Won; Kim, Young Joo; Lee, Seung Seok

    2004-01-01

    In this study, the capacitive micromachined ultrasonic transducer (cMUT) was developed. Theoretical analysis and finite element analysis of the behavior of membrane (such as resonance frequency, membrane deflection, collapse deflection and collapse voltage) of the cMUT were performed. The design parameters of the cMUT were estimated and are the dimension and thickness of membrane, thickness of sacrificial layer, thickness and size of electrode, size of active element and so on. With the micro-fabrication process, the cMUT was fabricated on the silicon wafer. To measure the membrane displacement of cMUT, the Michelson phase modulation fiber interferometer was constructed. The measured membrane displacement was good agreed with the result of finite element analysis. To estimate the ultrasonic wave generated by the cMUT, the ultrasonic transceiver system was constructed. The developed cMUT shows a good performance and hence will be widely used to the filed of non-contact ultrasonic application.

  10. Capacitive micromachined ultrasonic transducers with through-wafer interconnects

    Science.gov (United States)

    Zhuang, Xuefeng

    Capacitive micromachined ultrasonic transducer (CMUT) is a promising candidate for making ultrasound transducer arrays for applications such as 3D medical ultrasound, non-destructive evaluation and chemical sensing. Advantages of CMUTs over traditional piezoelectric transducers include low-cost batch fabrication, wide bandwidth, and ability to fabricate arrays with broad operation frequency range and different geometric configurations on a single wafer. When incorporated with through-wafer interconnects, a CMUT array can be directly integrated with a front-end integrated circuit (IC) to achieve compact packaging and to mitigate the effects of the parasitic capacitance from the connection cables. Through-wafer via is the existing interconnect scheme for CMUT arrays, and many other types of micro-electro-mechanical system (MEMS) devices. However, to date, no successful through-wafer via fabrication technique compatible with the wafer-bonding method of making CMUT arrays has been demonstrated. The through-wafer via fabrication steps degrade the surface conditions of the wafer, reduce the radius of curvature, thus making it difficult to bond. This work focuses on new through-wafer interconnect techniques that are compatible with common MEMS fabrication techniques, including both surface-micromachining and direct wafer-to-wafer fusion bonding. In this dissertation, first, a through-wafer via interconnect technique with improved characteristics is presented. Then, two implementations of through-wafer trench isolation are demonstrated. The through-wafer trench methods differ from the through-wafer vias in that the electrical conduction is through the bulk silicon instead of the conductor in the vias. In the first implementation, a carrier wafer is used to provide mechanical support; in the second, mechanical support is provided by a silicon frame structure embedded inside the isolation trenches. Both implementations reduce fabrication complexity compared to the through

  11. Modeling on energy harvesting from a railway system using piezoelectric transducers

    Science.gov (United States)

    Wang, Jianjun; Shi, Zhifei; Xiang, Hongjun; Song, Gangbing

    2015-10-01

    Theoretical models of piezoelectric energy harvesting from railway systems using patch-type and stack-type piezoelectric transducers are studied. An infinite Euler-Bernoulli beam on a Winkler foundation subjected to moving multi-loads is adopted to describe the dynamic behavior of railway track. The voltage and electric power of piezoelectric transducers installed at the bottom of a steel rail are derived analytically. Comparisons with earlier works and experimental results are given, indicating that the present solutions are reliable. Additionally, a parametric study is conducted to discuss the effects of axle loads, running velocity and load resistors on the solutions. The numerical results show that patch-type and stack-type piezoelectric transducers can harvest the available energy from track vibration to supply power for a wireless sensor network node and can also serve as sensors to monitor basic train information, such as the running velocity, the location and the axle load. The present investigations provide a theoretical guide in the design of piezoelectric patch and stack energy harvesters used in railway systems, which can serve as power sources for distributed wireless sensor networks in remote areas. The research results also demonstrate the potential of piezoelectric patches and stack harvesters in designing self-powered wireless sensor networks used in railway systems to ensure train operation safety.

  12. Motion Sensors and Transducers to Navigate an Intelligent Mechatronic Platform for Outdoor Applications

    Directory of Open Access Journals (Sweden)

    Michail G. PAPOUTSIDAKIS

    2016-03-01

    Full Text Available The initial goal of this project is to investigate if different sensor types and their attached transducers can support everyday human needs. Nowadays, there is a constant need to automate many time consuming applications not only in industrial environments but also in smaller scale applications, therefore robotics is a field that continuously tracks research interest. The area of human assistance by machines in everyday needs, continues to grow and to keep users interest very high. "Mechatronics" differ from Robotics in terms of integrated electronics, the advantage of being easily re-programmable and more over the versatility of hosting all kind of sensor types, sensor networks, transducers and actuators. In this research project, such an integrated autonomous device will be presented, focusing around the use of sensors and their feedback signals for proximity, position, motion, distance, placement and finally navigation. The ultimate sensor type choice for the task as well as all transducers signals management will also be highlighted. An up-to-date technology microcontroller will host all the above information and moreover move the mechatronic platform via motor actuators. The control algorithm which will be designed for the application is responsible for receiving all feedback signals, processing them and safely navigate the system in order to undertake its mission. The project scenario, the necessary electronic equipment and the controller design method will be highlighted in the following paragraphs of this document. Conclusions and results of sensor usage, platform's performance and problems solutions, forms the rest of this paper body.

  13. Investigations of the barbell ultrasonic transducer operated in the full-wave vibrational mode.

    Science.gov (United States)

    Fu, Zhiqiang; Xian, Xiaojun; Lin, Shuyu; Wang, Chenghui; Hu, Wenxu; Li, Guozheng

    2012-07-01

    In this paper, the resonance frequency equation and expression of displacement amplitude magnifications of a full-wave barber ultrasonic horn are obtained. By discussing the relationships between the displacement amplitude magnifications and the geometrical dimensions, the optimized design of the horn for the largest magnification is proposed, which is helpful to improve the radiation power and the transfer efficiency of the acoustic energy of the ultrasonic oscillatory system. Based on the optimized design of the horn, we introduced a barbell ultrasonic transducer operated in the longitudinal full-wave vibrational model and obtained the resonance frequency equations. For comparison, the resonance frequencies of the full-wave barbell horn and the full-wave barbell transducer are also analyzed by finite element method (FEM). It is shown that the values obtained by theoretical analysis and FEM are in good agreement with experimental observations. We hope that the research of this paper is helpful for the use of the barbell horn and transducer in the applications such as ultrasonic liquid processing. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. CMOS circuits for electromagnetic vibration transducers interfaces for ultra-low voltage energy harvesting

    CERN Document Server

    Maurath, Dominic

    2015-01-01

    Chip-integrated power management solutions are a must for ultra-low power systems. This enables not only the optimization of innovative sensor applications. It is also essential for integration and miniaturization of energy harvesting supply strategies of portable and autonomous monitoring systems. The book particularly addresses interfaces for energy harvesting, which are the key element to connect micro transducers to energy storage elements. Main features of the book are: - A comprehensive technology and application review, basics on transducer mechanics, fundamental circuit and control design, prototyping and testing, up to sensor system supply and applications. - Novel interfacing concepts - including active rectifiers, MPPT methods for efficient tracking of DC as well as AC sources, and a fully-integrated charge pump for efficient maximum AC power tracking at sub-100µW ultra-low power levels. The chips achieve one of widest presented operational voltage range in standard CMOS technology: 0.44V to over...

  15. Capacitive lamb wave transducers with multiple even-modes for biochemical detections

    Science.gov (United States)

    Ge, Li-Feng; Shao, Jin-Ping

    2010-08-01

    The high-order even-modes of high-aspect-ratio rectangular diaphragms are further exploited in this paper to excite Lamb waves. Thus the capacitive Lamb wave transducer (CLWT) can be excited by not only the second-order mode but also higher order even-modes, so that we can obtain higher operation frequencies, and make the CLWTs operate at several different frequencies for different applications. An optimized design with a 3μm thick silicon plate and submicrometer thick conducting silicon diaphragms is given according to the characteristics of the lowest order Lamb wave (i.e. A0 wave) and the TDK model for capacitive micromachined ultrasonic transducers (CMUT) with high-aspect-ratio rectangular diaphragms. Such a CLWT with multiple even-modes is significant and attractive for gas and liquid sensing in the field of biochemical measurements.

  16. A Four-Quadrant PVDF Transducer for Surface Acoustic Wave Detection

    Directory of Open Access Journals (Sweden)

    Zhi Chen

    2012-08-01

    Full Text Available In this paper, a polyvinylidene fluoride (PVDF piezoelectric transducer was developed to detect laser-induced surface acoustic waves in a SiO2-thin film–Si-substrate structure. In order to solve the problems related to, firstly, the position of the probe, and secondly, the fact that signals at different points cannot be detected simultaneously during the detection process, a four-quadrant surface acoustic wave PVDF transducer was designed and constructed for the purpose of detecting surface acoustic waves excited by a pulse laser line source. The experimental results of the four-quadrant piezoelectric detection in comparison with the commercial nanoindentation technology were consistent, the relative error is 0.56%, and the system eliminates the piezoelectric surface wave detection direction deviation errors, improves the accuracy of the testing system by 1.30%, achieving the acquisition at the same time at different testing positions of the sample.

  17. Specimen ferromagnetism and the behaviour of electromagnetic ultrasonic shear-wave transducers below and above the Curie point

    International Nuclear Information System (INIS)

    Robinson, T.S.

    1981-04-01

    Interest in the potentialities of electromagnetic ultrasonic transducers for non-destructive testing was re-awakened about 1968 and since then a goodly number of articles have appeared concerning transducers design, performance and use. The aim of this report is to fill a gap by describing the relations between theoretical and actual performance of shear-wave transducers, used on magnetic and on non-magnetic specimens: in particular to trace the phenomena occuring as the temperature of a magnetic specimen (mild steel) is raised through the Curie point. At the transmitting transducer generation of ultrasonic wave is almost exclusively by Lorentz forces applied to the skin of the specimen; at the receiver transduction is via Faraday induction. Wave attenuation in mild steel above the curie point hampers the use of shear waves, but does not render unusable there. An anomaly in performance with mild steel specimens just above the Curie temperature is discussed, which necessitates a brief consideration of electromagnetic longitudinal wave transducers, where the need to invoke magnetostriction as a dominant phenomenon is expressed. (Auhtor)

  18. Evaluation of design parameters of dental implant shape, diameter and length on stress distribution: a finite element analysis.

    Science.gov (United States)

    Mohammed Ibrahim, M; Thulasingam, C; Nasser, K S G A; Balaji, V; Rajakumar, M; Rupkumar, P

    2011-09-01

    The aim was to evaluate the design parameters of dental implants shape, diameter and length on stress distribution by finite element analysis (FEA).The objectives of the study was to compare the influence of stress distribution in the implants of screw-vent tapered and parallel design by varying the implant diameter with a standard implant length. Six dental implant models have been simulated three-dimensionally. The influence of diameter and length on stress distribution was evaluated by Group I: for screw-vent tapered design (Zimmer Dental Implant Carlsbad, CA, USA) (1) Dental implant model with diameter 3.7 mm and length 13 mm. (2) Dental implant model with diameter 4.1 mm and length 13 mm. (3) Dental implant model with diameter 4.7 mm and length 13 mm. Group II: for parallel design (Zimmer Dental Implant Carlsbad, CA, USA) (4) Dental implant model with diameter 3.7 mm and length 13 mm. (5) Dental implant model with diameter 4.1 mm and length 13 mm. (6) Dental implant model with diameter 4.7 mm and length 13 mm. The 3-D model of the implant was created in the pro-e wildfire 4.0 software by giving various commands. This model was imported to the ANSYS software through IGES (initial graphic exchange specification) file for further analysis. All six models were loaded with a force of 17.1, 114.6 and 23.4 N in a lingual, an axial and disto-mesial direction respectively, simulating average masticatory force in a natural oblique direction, to analyze the stress distribution on these implants. The increase in implant diameter in Group I and Group II from 3.7 to 4.1 mm and from 4.1 to 4.7 mm with constant 13 mm length for screw-vent tapered and parallel design implant resulted in a reduction in maximum value of Von Mises stress in the bone surrounding the implant was statistically significant at 5% level done by student "t" test. The overall maximum value of Von Mises stress was decreased in parallel design implant diameter of 4.7 mm with constant

  19. The influence of ventilation tube design on the magnitude of stress imposed at the implant/tympanic membrane interface.

    LENUS (Irish Health Repository)

    Vard, John P

    2008-03-01

    The design of ventilation tubes or grommets is thought to have a considerable influence on their performance. A computational model (finite element method) was used to investigate the significance of four design parameters of a commonly used design of ventilation tube. The design parameters were: the length of the shaft, the diameter of the flanges, the thickness of the flanges, and the material type. A statistical analysis technique, known as a factorial analysis of variance, was used to examine the importance of the four design parameters on the dynamical behaviour of the middle ear with the implant in situ and on the magnitude of stress induced at the implant\\/tympanic membrane interface. We predicted that the ventilation tube alters the frequency response of the middle ear; specifically the shaft length and the thickness of the flanges were found to have a significant effect upon the vibratory pattern at the umbo. A reduced length of tube and an increased size of flange were also found to be significant for minimising membrane stress (both with P<0.001). Thus, design parameters of critical influence on optimising performance were identified.

  20. Design parameters dependences on contact stress distribution in gait and jogging phases after total hip arthroplasty.

    Science.gov (United States)

    Rixrath, E; Wendling-Mansuy, S; Flecher, X; Chabrand, P; Argenson, J N

    2008-01-01

    We have developed a mathematical model to calculate the contact stress distribution in total hip arthroplasty (THA) prosthesis between the articulating surfaces. The model uses the clearance between bearing surfaces as well as the inclination and thickness of the Ultra High Molecular Weight Poly-Ethylene (UHMWPE) cup to achieve this. We have used this mathematical model to contrast the maximal force during normal gait and during jogging. This is based on the assumption that the contact stress is proportional to the radial deformation of the cup. The results show that the magnitude of the maximal contact stress remains constant for inclination values in the range of [0-35 degrees ] and increase significantly with the cup clearance and liner thickness for inclination values in the range of [35-65 degrees ]. A major use for this model would be the calculation of spatial contact stress distribution during normal gait or jogging for different couples of bearing surfaces.

  1. Air-coupled MUMPs capacitive micromachined ultrasonic transducers with resonant cavities.

    Science.gov (United States)

    Octavio Manzanares, Alberto; Montero de Espinosa, Francisco

    2012-04-01

    This work reports performance improvements of air-coupled capacitive micromachined ultrasonic transducers (CMUTs) using resonant cavities. In order to perform this work, we have designed and manufactured a CMUT employing multi-user microelectromechanical systems (MEMS) processes (MUMPs). The transducer was designed using Helmholtz resonator principles. This was characterised by the dimensions of the cavity and several acoustic ports, which had the form of holes in the CMUT plate. The MUMPs process has the advantage of being low cost which allows the manufacture of economic prototypes. In this paper we show the effects of the resonant cavities and acoustic ports in CMUTs using laser Doppler vibrometry and acoustical measurements. We also use Finite Element (FE) simulations in order to support experimental measurements. The results show that it is possible to enhance the output pressure and bandwidth in air by tuning the resonance frequency of the plate (f(p)) with that of the Helmholtz resonator (f(H)). The experimental measurements show the plate resonance along with an additional resonance in the output pressure spectrum. This appears due to the effect of the new resonant cavities in the transducer. FE simulations show an increase of 11 dB in the output pressure with respect to that of a theoretical vacuum-sealed cavity MUMPs CMUT by properly tuning the transducer. The bandwidth has been also analyzed by calculating the mechanical Q factor of the tuned CMUT. This has been estimated as 4.5 compared with 7.75 for the vacuum-sealed cavity MUMPs CMUT. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Academic stress in master’s students and its modulatory variables: a between-groups design

    OpenAIRE

    Barraza Macías, Arturo

    2009-01-01

    The present investigation tries to establish the descriptive profile of the academic stress of the students of the masters in education and to identify which sociodemographic and situational variables play a modulator role. This investigation is based on the Person-Surroundings Research Program and the systemical cognitive model of academic stress. The study can be characterized as transectional, correlational and non experimental. The collection of the information was made through the SISCO ...

  3. 3-D TECATE/BREW: Thermal, stress, and birefringent ray-tracing codes for solid-state laser design

    Science.gov (United States)

    Gelinas, R. J.; Doss, S. K.; Nelson, R. G.

    1994-07-01

    This report describes the physics, code formulations, and numerics that are used in the TECATE (totally Eulerian code for anisotropic thermo-elasticity) and BREW (birefringent ray-tracing of electromagnetic waves) codes for laser design. These codes resolve thermal, stress, and birefringent optical effects in 3-D stationary solid-state systems. This suite of three constituent codes is a package referred to as LASRPAK.

  4. A novel high pressure, high temperature vessel used to conduct long-term stability measurements of silicon MEMS pressure transducers

    Science.gov (United States)

    Wisniewiski, David

    2014-03-01

    The need to quantify and to improve long-term stability of pressure transducers is a persistent requirement from the aerospace sector. Specifically, the incorporation of real-time pressure monitoring in aircraft landing gear, as exemplified in Tire Pressure Monitoring Systems (TPMS), has placed greater demand on the pressure transducer for improved performance and increased reliability which is manifested in low lifecycle cost and minimal maintenance downtime through fuel savings and increased life of the tire. Piezoresistive (PR) silicon MEMS pressure transducers are the primary choice as a transduction method for this measurement owing to their ability to be designed for the harsh environment seen in aircraft landing gear. However, these pressure transducers are only as valuable as the long-term stability they possess to ensure reliable, real-time monitoring over tens of years. The "heart" of the pressure transducer is the silicon MEMS element, and it is at this basic level where the long-term stability is established and needs to be quantified. A novel High Pressure, High Temperature (HPHT) vessel has been designed and constructed to facilitate this critical measurement of the silicon MEMS element directly through a process of mechanically "floating" the silicon MEMS element while being subjected to the extreme environments of pressure and temperature, simultaneously. Furthermore, the HPHT vessel is scalable to permit up to fifty specimens to be tested at one time to provide a statistically significant data population on which to draw reasonable conclusions on long-term stability. With the knowledge gained on the silicon MEMS element, higher level assembly to the pressure transducer envelope package can also be quantified as to the build-effects contribution to long-term stability in the same HPHT vessel due to its accommodating size. Accordingly, a HPHT vessel offering multiple levels of configurability and robustness in data measurement is presented, along

  5. A quarter Wheatstone bridge strain gage force transducer for recording gut motility.

    Science.gov (United States)

    Cowles, V E; Condon, R E; Schulte, W J; Woods, J H; Sillin, L F

    1978-10-01

    Quarter and half Wheatstone bridge extraluminal force transducers for recording of gastrointestinal motility are compared. Modification of the transducer to a quarter bridge is economical, simplifies construction, and improves longevity by eliminating the crossover wire which frequently short circuits. The quarter bridge transducer was found to be as accurate and sensitive as the half bridge transducer.

  6. Design and simulation of thermal residual stresses of coatings on WC-Co cemented carbide cutting tool substrate

    International Nuclear Information System (INIS)

    Li, Anhai; Zhao, Jun; Zang, Jian; Zheng, Wei

    2016-01-01

    Large thermal residual stresses in coatings during the coating deposition process may easily lead to coating delamination of coated carbide tools in machining. In order to reduce the possibility of coating delamination during the tool failure process, a theoretical method was proposed and a numerical method was constructed for the coating design of WC-Co cemented carbide cutting tools. The thermal residual stresses of multi-layered coatings were analytically modeled based on equivalent parameters of coating properties, and the stress distribution of coatings are simulated by Finite element method (FEM). The theoretically calculated results and the FEM simulated results were verified and in good agreement with the experimental test results. The effects of coating thickness, tool substrate, coating type and interlayer were investigated by the proposed geometric and FEM model. Based on the evaluations of matchability of tool substrate and tool coatings, the basic principles of tool coating design were proposed. This provides theoretical basis for the selection and design of coatings of cutting tools in high-speed machining

  7. Design and simulation of thermal residual stresses of coatings on WC-Co cemented carbide cutting tool substrate

    Energy Technology Data Exchange (ETDEWEB)

    Li, Anhai; Zhao, Jun; Zang, Jian; Zheng, Wei [Key Laboratory of High Efficiency and Clean Mechanical Manufacture of MOE, School of Mechanical EngineeringShandong University, Jinan (China)

    2016-08-15

    Large thermal residual stresses in coatings during the coating deposition process may easily lead to coating delamination of coated carbide tools in machining. In order to reduce the possibility of coating delamination during the tool failure process, a theoretical method was proposed and a numerical method was constructed for the coating design of WC-Co cemented carbide cutting tools. The thermal residual stresses of multi-layered coatings were analytically modeled based on equivalent parameters of coating properties, and the stress distribution of coatings are simulated by Finite element method (FEM). The theoretically calculated results and the FEM simulated results were verified and in good agreement with the experimental test results. The effects of coating thickness, tool substrate, coating type and interlayer were investigated by the proposed geometric and FEM model. Based on the evaluations of matchability of tool substrate and tool coatings, the basic principles of tool coating design were proposed. This provides theoretical basis for the selection and design of coatings of cutting tools in high-speed machining.

  8. The effect of saddle design on stresses in the perineum during cycling.

    Science.gov (United States)

    Spears, Iain R; Cummins, Neil K; Brenchley, Zoe; Donohue, Claire; Turnbull, Carli; Burton, Shona; Macho, Gabrielle A

    2003-09-01

    Repetitive internal stress in the perineum has been associated with soft-tissue trauma in bicyclists. Using an engineering approach, the purpose of this study was to quantify the amount of compression exerted in the perineum for a range of saddle widths and orientations. Computer tomography was used to create a three-dimensional voxel-based finite element model of the right side of the male perineum-pelvis. For the creation of the saddle model, a commercially available saddle was digitized and the surface manipulated to represent a variety of saddle widths and orientations. The two models were merged, and a static downward load of 189 N was applied to the model at the region representing the sacroiliac joint. For validation purposes, external stresses along the perineum-saddle interface were compared with the results of pressure sensitive film. Good agreement was found for these external stresses. The saddles were then stretched and rotated, and the magnitude and location of maximum stresses within the perineum were both recorded. In all cases, the model of the pelvis-perineum was held in an upright position. Stresses within the perineum were reduced when the saddle was sufficiently wide to support both ischial tuberosities. This supporting mechanism was best achieved when the saddle was at least two times wider than the bi-ischial width of the cyclist. Stresses in the anterior of the perineum were reduced when the saddle was tilted downward, whereas stresses in the posterior were reduced when the saddle was tilted upward. Recommendations that saddles should be sufficiently wide to support the ischial tuberosities appear to be well founded. Recommendations that saddles be tilted downward (i.e., nose down) are supported by the model, but with caution, given the limitations of the model.

  9. Study Design and Results of a Population-Based Study on Perceived Stress Following Hurricane Sandy.

    Science.gov (United States)

    Schwartz, Rebecca; Liu, Bian; Sison, Cristina; Kerath, Samantha M; Breil, Trista; Murphy, Lisa; Taioli, Emanuela

    2016-06-01

    Hurricane Sandy was one of the deadliest storms in US history, with at least 162 deaths and numerous injuries. This research aimed to quantify the impact of Hurricane Sandy on the New York metropolitan area. The project included 601 volunteers aged at least 18 years who were recruited in Nassau, Suffolk, Queens, and Richmond counties and Staten Island between 2013 and 2014 through close partnerships with coalition community leaders. Participants completed a self-administered questionnaire on demographics and behavioral factors and a 35-point check off list on hurricane exposure. Perceived stress was assessed by using the 10-item Perceived Stress Scale (PSS). Participants had a mean stress score of 15.6 (SD=7.3; vs general population mean of 13.0), with 30.14% of the sample categorized as "high stress" (mean≥20). In the multivariable regression analysis, age was significantly negatively associated with PSS score. A reported history of mental health issues, Hispanic ethnicity, and overall exposure to Hurricane Sandy were statistically significantly associated with PSS score in a positive direction. Perceived stress was high in areas affected by Hurricane Sandy and was significantly associated with individual hurricane exposure. This study is a first step toward defining what segments of the population are more vulnerable and informing intervention and emergency preparedness efforts. (Disaster Med Public Health Preparedness. 2015;10:325-332).

  10. A finite element study on stress distribution of two different attachment designs under implant supported overdenture.

    Science.gov (United States)

    El-Anwar, Mohamed I; Yousief, Salah A; Soliman, Tarek A; Saleh, Mahmoud M; Omar, Wael S

    2015-10-01

    This study aimed to evaluate stress patterns generated within implant-supported mandibular overdentures retained by two different attachment types: ball and socket and locator attachments. Commercial CAD/CAM and finite element analysis software packages were utilized to construct two 3D finite element models for the two attachment types. Unilateral masticatory compressive loads of 50, 100, and 150 N were applied vertically to the overdentures, parallel to the longitudinal axes of the implants. Loads were directed toward the central fossa in the molar region of each overdenture, that linear static analysis was carried out to find the generated stresses and deformation on each part of the studied model. According to FEA results the ball attachment neck is highly stressed in comparison to the locator one. On the other hand mucosa and cortical bone received less stresses under ball and socket attachment. Locator and ball and socket attachments induce equivalent stresses on bone surrounding implants. Locator attachment performance was superior to that of the ball and socket attachment in the implants, nylon caps, and overdenture. Locator attachments are highly recommended and can increase the interval between successive maintenance sessions.

  11. Stress-corrosion cracking of steels in ammonia with consideration given to OTEC design: a survey

    Energy Technology Data Exchange (ETDEWEB)

    Teel, R.B.

    1980-03-01

    Carbon steel, alloy steel, and high-strength, quenched and tempered steel, when under applied or residual stress and especially when cold formed and/or welded without subsequent thermal stress relief, are subject to failure by stress-corrosion cracking (SCC) in air-contaminated dry ammonia. Water as well as hydrazine when present in small amounts have been shown to be effective inhibitors in an all steel system. Galvanic corrosion between dissimilar metals and/or accelerated failure by SCC of stressed steel as a result of galvanic coupling may be of concern. Where water has proven effective as an inhibitor of SCC in an all steel system, it may not be adequate in a mixed metal system. With aluminum tubes, the tube sheet will either have to be solid aluminum, aluminum clad steel or some nonconductive coating will be necessary to effectively remove the cathodic alloy from the galvanic circuit. Research is required to determine the severity of the coupling effect between dissimilar alloys in ammonia under OTEC conditions; especially the possibility of accelerated SCC failures of stressed steel where the presence of an inhibitor in the ammonia may not be sufficient to override the galvanic coupling effect.

  12. One-Piece Force-Transducer Body

    Science.gov (United States)

    Meyer, R. A.

    1986-01-01

    Rugged unit designed to operate in severe environment. Forcetransducer body designed for measurement of loads on specimens tested in hydrogen gas at temperatures up to 2,000 degree F (1,090 degree C). Body has symmetrical radial-shear-beam configuration and machined in one piece from bar stock.

  13. Mechanical stress analysis of microfluidic environments designed for isolated biological cell investigations.

    Science.gov (United States)

    Kohles, Sean S; Nève, Nathalie; Zimmerman, Jeremiah D; Tretheway, Derek C

    2009-12-01

    Advancements in technologies for assessing biomechanics at the cellular level have led to discoveries in mechanotransduction and the investigation of cell mechanics as a biomarker for disease. With the recent development of an integrated optical tweezer with micron resolution particle image velocimetry, the opportunity to apply controlled multiaxial stresses to suspended single cells is available (Neve, N., Lingwood, J. K., Zimmerman, J., Kohles, S. S., and Tretheway, D. C., 2008, "The muPIVOT: An Integrated Particle Image Velocimetry and Optical Tweezers Instrument for Microenvironment Investigations," Meas. Sci. Technol., 19(9), pp. 095403). A stress analysis was applied to experimental and theoretical flow velocity gradients of suspended cell-sized polystyrene microspheres demonstrating the relevant geometry of nonadhered spherical cells, as observed for osteoblasts, chondrocytes, and fibroblasts. Three flow conditions were assessed: a uniform flow field generated by moving the fluid sample with an automated translation stage, a gravity driven flow through a straight microchannel, and a gravity driven flow through a microchannel cross junction. The analysis showed that fluid-induced stresses on suspended cells (hydrodynamic shear, normal, and principal stresses in the range of 0.02-0.04 Pa) are generally at least an order of magnitude lower than adhered single cell studies for uniform and straight microchannel flows (0.5-1.0 Pa). In addition, hydrostatic pressures dominate (1-100 Pa) over hydrodynamic stresses. However, in a cross junction configuration, orders of magnitude larger hydrodynamic stresses are possible without the influence of physical contact and with minimal laser trapping power.

  14. Oil–water two-phase flow measurement with combined ultrasonic transducer and electrical sensors

    International Nuclear Information System (INIS)

    Tan, Chao; Yuan, Ye; Dong, Xiaoxiao; Dong, Feng

    2016-01-01

    A combination of ultrasonic transducers operated in continuous mode and a conductance/capacitance sensor (UTCC) is proposed to estimate the individual flow velocities in oil–water two-phase flows. Based on the Doppler effect, the transducers measure the flow velocity and the conductance/capacitance sensor estimates the phase fraction. A set of theoretical correlations based on the boundary layer models of the oil–water two-phase flow was proposed to describe the velocity profile. The models were separately established for the dispersion flow and the separate flow. The superficial flow velocity of each phase is calculated with the velocity measured in the sampling volume of the ultrasonic transducer with the phase fraction through the velocity profile models. The measuring system of the UTCC was designed and experimentally verified on a multiphase flow loop. The results indicate that the proposed system and correlations estimate the overall flow velocity at an uncertainty of U J   =  0.038 m s −1 , and the water superficial velocity at U Jw   =  0.026 m s −1 , and oil superficial velocity at U Jo   =  0.034 m s −1 . The influencing factors of uncertainty were analyzed. (paper)

  15. Acoustic streaming in the transducer plane in ultrasonic particle manipulation devices.

    Science.gov (United States)

    Lei, Junjun; Glynne-Jones, Peter; Hill, Martyn

    2013-06-07

    In acoustofluidic manipulation and sorting devices, Rayleigh streaming flows are typically found in addition to the acoustic radiation forces. However, experimental work from various groups has described acoustic streaming that occurs in planar devices in a plane parallel to the transducer face. This is typically a four-quadrant streaming pattern with the circulation parallel to the transducer. Understanding its origins is essential for creating designs that limit or control this phenomenon. The cause of this kind of streaming pattern has not been previously explained as it is different from the well-known classical streaming patterns such as Rayleigh streaming and Eckart streaming, whose circulation planes are generally perpendicular to the face of the acoustic transducer. In order to gain insight into these patterns we present a numerical method based on Nyborg's limiting velocity boundary condition that includes terms ignored in the Rayleigh analysis, and verify its predictions against experimental PIV results in a simple device. The results show that the modelled particle trajectories match those found experimentally. Analysis of the dominant terms in the driving equations shows that the origin of this kind of streaming pattern is related to the circulation of the acoustic intensity.

  16. SAFE-3D analysis of a piezoelectric transducer to excite guided waves in a rail web

    Science.gov (United States)

    Ramatlo, Dineo A.; Long, Craig S.; Loveday, Philip W.; Wilke, Daniel N.

    2016-02-01

    Our existing Ultrasonic Broken Rail Detection system detects complete breaks and primarily uses a propagating mode with energy concentrated in the head of the rail. Previous experimental studies have demonstrated that a mode with energy concentrated in the head of the rail, is capable of detecting weld reflections at long distances. Exploiting a mode with energy concentrated in the web of the rail would allow us to effectively detect defects in the web of the rail and could also help to distinguish between reflections from welds and cracks. In this paper, we will demonstrate the analysis of a piezoelectric transducer attached to the rail web. The forced response at different frequencies is computed by the Semi-Analytical Finite Element (SAFE) method and compared to a full three-dimensional finite element method using ABAQUS. The SAFE method only requires the rail track cross-section to be meshed using two-dimensional elements. The ABAQUS model in turn requires a full three-dimensional discretisation of the rail track. The SAFE approach can yield poor predictions at cut-on frequencies associated with other modes in the rail. Problematic frequencies are identified and a suitable frequency range identified for transducer design. The forced response results of the two methods were found to be in good agreement with each other. We then use a previously developed SAFE-3D method to analyse a practical transducer over the selected frequency range. The results obtained from the SAFE-3D method are in good agreement with experimental measurements.

  17. High Precision UTDR Measurements by Sonic Velocity Compensation with Reference Transducer

    Directory of Open Access Journals (Sweden)

    Sam Stade

    2014-07-01

    Full Text Available An ultrasonic sensor design with sonic velocity compensation is developed to improve the accuracy of distance measurement in membrane modules. High accuracy real-time distance measurements are needed in membrane fouling and compaction studies. The benefits of the sonic velocity compensation with a reference transducer are compared to the sonic velocity calculated with the measured temperature and pressure using the model by Belogol’skii, Sekoyan et al. In the experiments the temperature was changed from 25 to 60 °C at pressures of 0.1, 0.3 and 0.5 MPa. The set measurement distance was 17.8 mm. Distance measurements with sonic velocity compensation were over ten times more accurate than the ones calculated based on the model. Using the reference transducer measured sonic velocity, the standard deviations for the distance measurements varied from 0.6 to 2.0 µm, while using the calculated sonic velocity the standard deviations were 21–39 µm. In industrial liquors, not only the temperature and the pressure, which were studied in this paper, but also the properties of the filtered solution, such as solute concentration, density, viscosity, etc., may vary greatly, leading to inaccuracy in the use of the Belogol’skii, Sekoyan et al. model. Therefore, calibration of the sonic velocity with reference transducers is needed for accurate distance measurements.

  18. Development of Fibre Bragg grating (FBG) dynamic pressure transducer with diminutive voltage inconsistency

    Science.gov (United States)

    Aizzuddin, A. M.; Hafizi, Z. M.; Kee, L. V.; Vorathin, E.; Lim, K. S.

    2017-10-01

    In this work, a diaphragm-type Fibre Bragg grating (FBG) dynamic pressure transducer was designed and developed. Pressure transducer in this study consists of elastic thin metal diaphragm which acts as a primary sensing element; and integrated with an FBG sensor for the secondary sensing element. In the common match filter interrogation system, converting optical signal to voltage is the challenging due to voltage reading inconsistency, which would cause variation in pressure reading. New alternative arrangements of matched filter interrogation system are used to address the issue. For automated pressure measurement, the optical signal from FBG was converted into voltage by using the proposed arrangement of matched filter interrogation system. Additional FBG was added as reference sensor which installed in the system for detection the change of broadband light source. Reduction of voltage inconsistency was achieved by normalizing the voltage reading from sensor with the voltage reading from reference FBG. The result shows that the FBG pressure transducer is proven to be suitable for pressure measurement of gas or liquid with an average error of 5.348%. Furthermore, the FBG sensor has a good linearity with a linear correlation coefficient of 97.29% in pressure measurement.

  19. Molecular characterization of a new efficiently transducing bacteriophage identified in meticillin-resistant Staphylococcus aureus.

    Science.gov (United States)

    Varga, Marian; Pantůček, Roman; Růžičková, Vladislava; Doškař, Jirˇí

    2016-01-01

    In Staphylococcus aureus, generalized transduction mediated by temperate bacteriophages represents a highly efficient way of transferring antibiotic resistance genes between strains. In the present study, we identified and characterized in detail a new efficiently transducing bacteriophage of the family Siphoviridae, designated ϕJB, which resides as a prophage in the meticillin-resistant S. aureus (MRSA) strain Jevons B. Whole-genome sequencing followed by detailed in silico analysis uncovered a linear dsDNA genome consisting of 43 ,12 bp and comprising 70 ORFs, of which ∼40 encoded proteins with unknown function. A global genome alignment of ϕJB and other efficiently transducing phages ϕ11, ϕ53, ϕ80, ϕ80α and ϕNM4 showed a high degree of homology with ϕNM4 and substantial differences with regard to other phages. Using a model transduction system with a well-defined donor and recipient, ϕJB transferred the tetracycline resistance plasmid pT181 and a penicillinase plasmid with outstanding frequencies, beating most of the above-mentioned phages by an order of magnitude. Moreover, ϕJB demonstrated high frequencies of transferring antibiotic resistance plasmids even upon induction from a lysogenic donor strain. Considering such transducing potential, ϕJB and related bacteriophages may serve as a suitable tool for elucidating the nature of transduction and its contribution to the spread of antibiotic resistance genes in naturally occurring MRSA populations.

  20. Evaluation of a novel therapeutic focused ultrasound transducer based on Fermat’s spiral

    Science.gov (United States)

    Ramaekers, P.; de Greef, M.; Berriet, R.; Moonen, C. T. W.; Ries, M.

    2017-06-01

    The purpose of this study was to evaluate a novel phased array transducer design rule for therapeutic focused ultrasound applications. This design rule uses the discretized Fermat’s spiral to determine the positioning of the transducer elements for a given number of elements and f-number. Using this principle, three variations of Fermat’s spiral were generated, aimed at (1) grating lobe minimization, (2) side lobe minimization, and (3) an optimized element packing efficiency. For each spiral, sparse layouts using identical circular elements and fully populated layouts based on additional Voronoi tessellation were evaluated numerically. Evaluation criteria included the element size distribution, beam steering capabilities, focal plane pressure distribution, prefocal pressure distribution, and practical considerations. Finally, one Voronoi-tessellated design with a focal length and aperture diameter of 16 cm and a natural frequency of 1.3 MHz was evaluated experimentally through hydrophone measurements. The numerical evaluation showed that while sparse arrays possess superior beam steering capabilities for a given number of elements, the focal point quality and prefocal pressure distribution is substantially more favorable when using the Voronoi-tessellated designs. Beam steering was shown to be feasible with the tessellated designs for lateral deflections up to 10 mm and axial deflections up to 20 mm. The experimental evaluation showed that such a transducer is capable of inducing 40.00 MPa rarefactional and 237.50 MPa compressional peak pressure levels at 800 W instantaneous acoustic output power under free-field conditions, making the system potentially relevant for thermal ablation therapy, histotripsy applications, and shockwave-enhanced heating.

  1. Thin-plate-type embedded ultrasonic transducer based on magnetostriction for the thickness monitoring of the secondary piping system of a nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Tae Hoon; Cho, Seung Hyun [Center for Safety Measurement, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2016-12-15

    Pipe wall thinning in the secondary piping system of a nuclear power plant is currently a major problem that typically affects the safety and reliability of the nuclear power plant directly. Regular in-service inspections are carried out to manage the piping system only during the overhaul. Online thickness monitoring is necessary to avoid abrupt breakage due to wall thinning. To this end, a transducer that can withstand a high-temperature environment and should be installed under the insulation layer. We propose a thin plate type of embedded ultrasonic transducer based on magnetostriction. The transducer was designed and fabricated to measure the thickness of a pipe under a high-temperature condition. A number of experimental results confirmed the validity of the present transducer.

  2. Evaluation of stress pattern generated through various thread designs of dental implants loaded in a condition of immediately after placement and on osseointegration--an FEA study.

    Science.gov (United States)

    Chowdhary, Ramesh; Halldin, Anders; Jimbo, Ryo; Wennerberg, Ann

    2013-02-01

    To determine the stress pattern generated through various thread design in experimental simulation models, when loaded immediately after placement and after osseointegration. Three-dimensional (3D) models were designed using CATIA, computer-aided design modeling software. The study was planned in 2 stages. Eight 2D models were constructed of different thread forms, one set with frictionless and other with bonded for bone to implant interface and loaded vertically with 100 N. In Stage II, 6 3D models of the different threads embedded in the cortical bone were constructed and loaded vertically and obliquely. In 2D models, the von Mises stress concentrated at the crest in the bonded connection thread designs. The stress levels were in the range of 7 to 13 MPa. In the frictional implant bone interface, the thread designs had a clear effect on the stress levels in the bone. In the 3D analysis, the complete implant design affected the stress levels. The thread design affects the magnitude of the stress peak in the bone more effectively in immediately loaded (frictionless) implants than the osseointegrated (bonded) implants. Maximum stress was observed at the first thread in most of the osseointegrated implants.

  3. Resonance tracking and vibration stablilization for high power ultrasonic transducers.

    Science.gov (United States)

    Kuang, Y; Jin, Y; Cochran, S; Huang, Z

    2014-01-01

    Resonant frequency shift and electrical impedance variation are common phenomena in the application of high power ultrasonic transducers, e.g. in focused ultrasound surgery and in cutting. They result in low power efficiency and unstable vibration amplitude. To solve this problem, a driving and measurement system has been developed to track the resonance of high power transducers and to stabilise their vibration velocity. This has the ability to monitor the operating and performance parameters of the ultrasonic transducers in real time. The configuration of the system, with its control algorithm implemented in LabVIEW (National Instruments, Newbury, UK), ensures flexibility to suit different transducers and load conditions. In addition, with different programs, it can be utilised as a high power impedance analyser or an instantaneous electrical power measurement system for frequencies in the MHz range. The effectiveness of this system has been demonstrated in detailed studies. With it, high transducer performance at high power can be achieved and monitored in real time. Copyright © 2013. Published by Elsevier B.V.

  4. Aircraft components structural health monitoring using flexible ultrasonic transducer arrays

    Science.gov (United States)

    Liu, W.-L.; Jen, C.-K.; Kobayashi, M.; Mrad, N.

    2011-04-01

    A damage detection capability based on a flexible ultrasonic transducer (FUT) array bonded onto a planar and a curved surface is presented. The FUT array was fabricated on a 75 μm titanium substrate using sol-gel spray technique. Room temperature curable adhesive is used as the bonding agent and ultrasonic couplant between the transducer and the test article. The bonding agent was successfully tested for aircraft environmental temperatures between -80 °C and 100 °C. For a planar test article, selected FUT arrays were able to detect fasteners damage within a planar distance of 176 mm, when used in the pulse-echo mode. Such results illustrate the effectiveness of the developed FUT transducer as compared to commercial 10MHz ultrasonic transducer (UT). These FUT arrays were further demonstrated on a curved test article. Pulse-echo measurements confirmed the reflected echoes from the specimen. Such measurement was not possible with commercial UTs due to the curved nature of the test article and its accessibility, thus demonstrating the suitability and superiority of the developed flexible ultrasonic transducer capability.

  5. A Driver for Piezoelectric Transducers with Control of Resonance

    Science.gov (United States)

    Arnold, F. J.; Ximenes, R. L.; Arthur, R.; Mühlen, S. S.

    Variations in electric impedance curves of piezoeletric transducers occur under influence of mechanical load, temperature, electric excitation, among others. Electronic circuits for driving these transducers should correct the tune to maintain the performance of the transducer. Considering the changes at resonance, we have developed a circuit for a laboratory bench that performs two functions. The first, working on low power, by swapping frequencies around resonance, allows to the user define electric impedance and frequency operation that intend to apply in the experiment. The operation of this circuit is based on detection of magnitude of current in the transducer. A microcontroller and Labview are used to obtain the results. In the second, while under high power operation, deviations from original impedance are corrected by using a feedback network that evaluates amplitude of impedance. In this circuit, a class D MOSFET amplifier is used for exciting the transducer. Also, a microcontroller system controls the feedback network. Experiments with variation of mechanical loads have shown the effectiveness of the system.

  6. Acousto-chemical analysis in multi-transducer sonochemical reactors for biodiesel production.

    Science.gov (United States)

    Hussain, Mohammed Noorul; Janajreh, Isam

    2018-01-01

    Biodiesel is a powerful alternative fuel that is less polluting and problematic to produce and implement. The production process of biodiesel also gives us the byproduct glycerol, which is a useful feedstock to produce hydrogen and syngas as fuels. With such high value as a fuel we are in need of better production technologies for biodiesel, which is currently being pursued through sonochemical reactors. The development of continuous sonochemical reactors for biodiesel production is a crucial requirement for the biofuel industry. Sonochemical reactors make use of ultrasound and acoustic cavitation to produce biodiesel from waste cooking oils (WCO). In this work we carried out both numerical simulation and experimental analysis of sonochemical reactors with multiple transducers. Through simulation, the effect of double vs a single transducer has been tested for a continuous flow sonochemical reactor. In experimental work three different cases with different ultrasound systems (bath, probe and bath+probe) have been tested. In both the studies, acoustic pressure and biodiesel conversion are analyzed. Results for the simulation show that in shorter reactors, the high cavitation from two transducers dampens the acoustic pressures leading to low conversion. However, at taller heights the effect of combined cavitation is less severe and the acoustic pressure and biodiesel yield are very similar between the designs having single and double transducers. From experiments it was found that the biodiesel conversion depends on several acoustic conditions mainly cavitation. A meticulous and insightful analysis was made to understand the difference in bath type and probe type ultrasound systems on acoustic pressure and biodiesel conversion. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Design, fabrication and test of lightweight shell structure. [axial compression loads and torsion stress

    Science.gov (United States)

    Lager, J. R.

    1975-01-01

    A cylindrical shell structure 3.66 m (144 in.) high by 4.57 m (180 in.) diameter was designed using a wide variety of materials and structural concepts to withstand design ultimate combined loading 1225.8 N/cm (700 lb/in.) axial compression and 245.2 N/cm (140 lb/in.) torsion. The overall cylinder geometry and design loading are representative of that expected on a high performance space tug vehicle. The relatively low design load level results in designs that use thin gage metals and fibrous-composite laminates. Fabrication and structural tests of small panels and components representative of many of the candidate designs served to demonstrate proposed fabrication techniques and to verify design and analysis methods. Three of the designs evaluated, honeycomb sandwich with aluminum faceskins, honeycomb sandwich with graphite/epoxy faceskins, and aluminum truss with fiber-glass meteoroid protection layers, were selected for further evaluation.

  8. Finite Element Analysis of Grouting Compactness Monitoring in a Post-Tensioning Tendon Duct Using Piezoceramic Transducers.

    Science.gov (United States)

    Jiang, Tianyong; Zheng, Junbo; Huo, Linsheng; Song, Gangbing

    2017-09-29

    With the development of the post-tensioning technique, prestressed concrete structures have been widely used in civil engineering. To ensure the long-term effectiveness of the prestressed tendon, the grouting quality of the tendon duct is one of the important factors. However, it is still a challenge to monitor the grouting quality of post-tensioning tendon ducts, due to the invisibility of the grouting. The authors' previous work proposed a real-time method that employed a stress wave-based active sensing approach with piezoceramic transducers to monitor the grouting compactness of a Post-Tensioning Tendon Duct (PTTD). To further understand the piezoceramic induced stress wave propagation in the PTTD with different grouting levels, this paper develops a two-dimensional finite element model for monitoring the grouting compactness of the tendon duct with a piezoceramic transducer. A smart aggregate (SA) developed to utilize one Lead Zirconate Titanate (PZT) transducer with marble protection is installed in the center location of the tendon duct as an actuator. Two PZT patches are bonded on the bottom and top surface of the tendon duct as the sensors. The analysis results show that the finite element analysis results are in good agreement with the experimental results, which demonstrates that the finite element analysis is feasible and reliable. For the top half of the specimen, not much stress wave could be detected before the full grouting level, except for negligible signals that may propagate through the walls of the tendon duct. When the tendon duct grouting is at 100%, the stress wave propagates to the top of the specimen, and the displacements are symmetric in both left-right and top-bottom directions before the stress waves reach the boundary. The proposed two-dimensional finite element model has the potential to be implemented to simulate the stress wave propagation principle for monitoring grouting compaction of the post-tensioning tendon duct.

  9. Finite Element Analysis of Grouting Compactness Monitoring in a Post-Tensioning Tendon Duct Using Piezoceramic Transducers

    Directory of Open Access Journals (Sweden)

    Tianyong Jiang

    2017-09-01

    Full Text Available With the development of the post-tensioning technique, prestressed concrete structures have been widely used in civil engineering. To ensure the long-term effectiveness of the prestressed tendon, the grouting quality of the tendon duct is one of the important factors. However, it is still a challenge to monitor the grouting quality of post-tensioning tendon ducts, due to the invisibility of the grouting. The authors’ previous work proposed a real-time method that employed a stress wave-based active sensing approach with piezoceramic transducers to monitor the grouting compactness of a Post-Tensioning Tendon Duct (PTTD. To further understand the piezoceramic induced stress wave propagation in the PTTD with different grouting levels, this paper develops a two-dimensional finite element model for monitoring the grouting compactness of the tendon duct with a piezoceramic transducer. A smart aggregate (SA developed to utilize one Lead Zirconate Titanate (PZT transducer with marble protection is installed in the center location of the tendon duct as an actuator. Two PZT patches are bonded on the bottom and top surface of the tendon duct as the sensors. The analysis results show that the finite element analysis results are in good agreement with the experimental results, which demonstrates that the finite element analysis is feasible and reliable. For the top half of the specimen, not much stress wave could be detected before the full grouting level, except for negligible signals that may propagate through the walls of the tendon duct. When the tendon duct grouting is at 100%, the stress wave propagates to the top of the specimen, and the displacements are symmetric in both left-right and top-bottom directions before the stress waves reach the boundary. The proposed two-dimensional finite element model has the potential to be implemented to simulate the stress wave propagation principle for monitoring grouting compaction of the post-tensioning tendon

  10. The Power of Role Design: Balancing the Principals Financial Responsibility with the Implications of Stress

    Science.gov (United States)

    Lindberg, Erik

    2012-01-01

    The Anglo-Saxon countries have implemented Management by Objectives (MBO) complemented with school-based management (SBM) fairly rapidly. Although these countries are considered something of a benchmark of stability, research on principals reveals that they experience high levels of stress and that this is associated with poorer job performance.…

  11. Heart Rate Variability Biofeedback Stress Relief Program for Depression A Replicated Single-Subject Design

    NARCIS (Netherlands)

    Hartogs, Bregje M. A.; Bartels-Velthuis, Agna A.; Van der Ploeg, Karen; Bos, Elske H.

    2017-01-01

    Background: Depressive disorders often have a chronic course and the efficacy of evidence-based treatments may be overestimated. Objective: To examine the effectiveness of the Heart Rate Variability Stress Reduction Program (SRP) as a supplement to standard treatment in patients with depressive

  12. A finite element study on stress distribution of two different attachment designs under implant supported overdenture

    Directory of Open Access Journals (Sweden)

    Mohamed I. El-Anwar

    2015-10-01

    Conclusions: Locator and ball and socket attachments induce equivalent stresses on bone surrounding implants. Locator attachment performance was superior to that of the ball and socket attachment in the implants, nylon caps, and overdenture. Locator attachments are highly recommended and can increase the interval between successive maintenance sessions.

  13. Towards the application of stress-in-motion (SIM) results in pavement design and infrastructure protection

    CSIR Research Space (South Africa)

    De Beer, Morris

    2004-03-01

    Full Text Available The aim of this paper is to highlight the approach and application of the Stress-In-Motion (SIM) technology to assist in an improved definition of the actual tyre / pavement interaction of modern heavy vehicles and their loads on the current road...

  14. Stress grades and design properties for lumber, round timber, and ties

    Science.gov (United States)

    David E. Kretschmann

    2010-01-01

    Round timbers, ties, and lumber sawn from a log, regardless of species and size, are quite variable in mechanical properties. Pieces may differ in strength by several hundred percent. For simplicity and economy in use, pieces of wood of similar mechanical properties are placed in categories called stress grades, which are characterized by (a) one or more sorting...

  15. Modelling tyre-road contact stresses in pavement design and analysis

    CSIR Research Space (South Africa)

    Maina, JW

    2013-07-01

    Full Text Available distribution is idealised with a multitude of circular and rectangular shapes, mimicking the non-uniform characteristics of the contact stresses inside the tyre contact patch. An example, in terms of pavement layer life and strain energy of distortion, is given...

  16. Normal Stresses in a Granular Material Under Falling Weight Deflectometer loading

    DEFF Research Database (Denmark)

    Ullidtz, Per; Askegaar, Vagn; Sjølin, Finn Ole

    1996-01-01

    The vertical normal stress under a falling weight deflectometer (FWD) was measured in a sand. The material had more than 90 percent falling within the sand fraction from 60 micrometer to 2 mm. The stress was measured with three different transducers. All transducers were installed at a depth of 2...

  17. Inspection of complex geometry pieces with an intelligent contact transducer

    International Nuclear Information System (INIS)

    Chatillon, S.; Roy, O.; Mahaut, St.

    2000-01-01

    A new multi-element contact transducer has been developed to improve the inspection of components with complex geometry. The emitting surface is flexible in order to optimize the contact with pieces. An algorithm, based on a simplified geometric model, has been used to determine the delays law which allows to control the focal characteristics of the transmitted field. Acquisition data lead in transmission with an articulated transducer validate the behavior provided by simulation. Thus the optimization of the delays law ensures the transmission of a beam which is homogeneous and controlled during the moving of the transducer. Inspections in echo-pulse mode are implemented on a sample simulating a component controlled on site. Results show that the dynamical adaptation of the delays law to the geometry of the piece leads to very good performances

  18. Inter digital transducer modelling through Mason equivalent circuit model

    DEFF Research Database (Denmark)

    Mishra, Dipti; Singh, Abhishek; Hussain, Dil muhammed Akbar

    2016-01-01

    The frequency reliance of inter-digital transducer is analyzed with the help of MASON's Equivalent circuit which is based on Smith's Equivalent circuit which is further based on Foster's Network. An inter-digital transducer has been demonstrated as a RLC network. The circuit is simulated...... by Simulation program with Integrated Circuit Emphasis (HSPICE), a well-liked electronic path simulator. The acoustic wave devices are not suitable to simulation through circuit simulator. In this paper, an electrical model of Mason's Equivalent electrical circuit for an inter-digital transducer (IDT......) is projected which is well-suited with a broadly cast-off universal resolution circuit simulator SPICE built-in out with the proficiency to simulate the negative capacitances and inductances. The investigation is done to prove the straightforwardness of establishing the frequency and time domain physical...

  19. A Novel Device for Total Acoustic Output Measurement of High Power Transducers

    Science.gov (United States)

    Howard, S.; Twomey, R.; Morris, H.; Zanelli, C. I.

    2010-03-01

    The objective of this work was to develop a device for ultrasound power measurement applicable over a broad range of medical transducer types, orientations and powers, and which supports automatic measurements to simplify use and minimize errors. Considering all the recommendations from standards such as IEC 61161, an accurate electromagnetic null-balance has been designed for ultrasound power measurements. The sensing element is placed in the water to eliminate errors due to surface tension and water evaporation, and the motion and detection of force is constrained to one axis, to increase immunity to vibration from the floor, water sloshing and water surface waves. A transparent tank was designed so it could easily be submerged in a larger tank to accommodate large transducers or side-firing geometries, and can also be turned upside-down for upward-firing transducers. A vacuum lid allows degassing the water and target in situ. An external control module was designed to operate the sensing/driving loop and to communicate to a local computer for data logging. The sensing algorithm, which incorporates temperature compensation, compares the feedback force needed to cancel the motion for sources in the "on" and "off" states. These two states can be controlled by the control unit or manually by the user, under guidance by a graphical user interface (the system presents measured power live during collection). Software allows calibration to standard weights, or to independently calibrated acoustic sources. The design accommodates a variety of targets, including cone, rubber, brush targets and an oil-filled target for power measurement via buoyancy changes. Measurement examples are presented, including HIFU sources operating at powers from 1 to 100.

  20. Optimization Design of Structures Subjected to Transient Loads Using First and Second Derivatives of Dynamic Displacement and Stress

    Directory of Open Access Journals (Sweden)

    Qimao Liu

    2012-01-01

    Full Text Available This paper developed an effective optimization method, i.e., gradient-Hessian matrix-based method or second order method, of frame structures subjected to the transient loads. An algorithm of first and second derivatives of dynamic displacement and stress with respect to design variables is formulated based on the Newmark method. The inequality time-dependent constraint problem is converted into a sequence of appropriately formed time-independent unconstrained problems using the integral interior point penalty function method. The gradient and Hessian matrixes of the integral interior point penalty functions are also computed. Then the Marquardt's method is employed to solve unconstrained problems. The numerical results show that the optimal design method proposed in this paper can obtain the local optimum design of frame structures and sometimes is more efficient than the augmented Lagrange multiplier method.

  1. Test rig with active damping control for the simultaneous evaluation of vibration control and energy harvesting via piezoelectric transducers

    International Nuclear Information System (INIS)

    Perfetto, S; Rohlfing, J; Infante, F; Mayer, D; Herold, S

    2016-01-01

    Piezoelectric transducers can be used to harvest electrical energy from structural vibrations in order to power continuously operating condition monitoring systems local to where they operate. However, excessive vibrations can compromise the safe operation of mechanical systems. Therefore, absorbers are commonly used to control vibrations. With an integrated device, the mechanical energy that otherwise would be dissipated can be converted via piezoelectric transducers. Vibration absorbers are designed to have high damping factors. Hence, the integration of transducers would lead to a low energy conversion. Efficient energy harvesters usually have low damping capabilities; therefore, they are not effective for vibration suppression. Thus, the design of an integrated device needs to consider the two conflicting requirements on the damping. This study focuses on the development of a laboratory test rig with a host structure and a vibration absorber with tunable damping via an active relative velocity feedback. A voice coil actuator is used for this purpose. To overcome the passive damping effects of the back electromagnetic force a novel voltage feedback control is proposed, which has been validated both in simulation and experimentally. The aim of this study is to have a test rig ready for the introduction of piezo-transducers and available for future experimental evaluations of the damping effect on the effectiveness of vibration reduction and energy harvesting efficiency. (paper)

  2. Test rig with active damping control for the simultaneous evaluation of vibration control and energy harvesting via piezoelectric transducers

    Science.gov (United States)

    Perfetto, S.; Rohlfing, J.; Infante, F.; Mayer, D.; Herold, S.

    2016-09-01

    Piezoelectric transducers can be used to harvest electrical energy from structural vibrations in order to power continuously operating condition monitoring systems local to where they operate. However, excessive vibrations can compromise the safe operation of mechanical systems. Therefore, absorbers are commonly used to control vibrations. With an integrated device, the mechanical energy that otherwise would be dissipated can be converted via piezoelectric transducers. Vibration absorbers are designed to have high damping factors. Hence, the integration of transducers would lead to a low energy conversion. Efficient energy harvesters usually have low damping capabilities; therefore, they are not effective for vibration suppression. Thus, the design of an integrated device needs to consider the two conflicting requirements on the damping. This study focuses on the development of a laboratory test rig with a host structure and a vibration absorber with tunable damping via an active relative velocity feedback. A voice coil actuator is used for this purpose. To overcome the passive damping effects of the back electromagnetic force a novel voltage feedback control is proposed, which has been validated both in simulation and experimentally. The aim of this study is to have a test rig ready for the introduction of piezo-transducers and available for future experimental evaluations of the damping effect on the effectiveness of vibration reduction and energy harvesting efficiency.

  3. Development of new eardrum-inspired acoustic transducers

    Science.gov (United States)

    Kim, Gi-Woo; Jung, Gwang-Yong; Kim, Kyu-Sung

    2017-04-01

    The eardrum (also known as tympanic membrane, TM) in human auditory system has a curved conical shape with the apex pointing medially. It generally receives airborne sound waves collected by the outer ear, transforms them into mechanical vibrations in the eardrum, and eventually transmits the vibrations to the middle ear, which is similar with acoustic transducers such as microphones. In this research, new approach inspired by the human auditory system is explored to address the challenging difficulties for developing advanced acoustic transducers. In addition, a frequency response function analysis is performed to validate the inverse anti-resonance vibrating structure inspired by human middle ear including ear-drum.

  4. Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study.

    Science.gov (United States)

    Aunmeungtong, W; Khongkhunthian, P; Rungsiyakull, P

    2016-01-01

    Finite Element Analysis (FEA) has been used for prediction of stress and strain between dental implant components and bone in the implant design process. Purpose of this study was to characterize and analyze stress and strain distribution occurring in bone and implants and to compare stress and strain of three different implant designs. Three different mini dental implant designs were included in this study: 1. a mini dental implant with an internal implant-abutment connection (MDIi); 2. a mini dental implant with an external implant-abutment connection (MDIe); 3. a single piece mini dental implant (MDIs). All implant designs were scanned using micro-CT scans. The imaging details of the implants were used to simulate models for FEA. An artificial bone volume of 9×9 mm in size was constructed and each implant was placed separately at the center of each bone model. All bone-implant models were simulatively loaded under an axial compressive force of 100 N and a 45-degree force of 100 N loading at the top of the implants using computer software to evaluate stress and strain distribution. There was no difference in stress or strain between the three implant designs. The stress and strain occurring in all three mini dental implant designs were mainly localized at the cortical bone around the bone-implant interface. Oblique 45° loading caused increased deformation, magnitude and distribution of stress and strain in all implant models. Within the limits of this study, the average stress and strain in bone and implant models with MDIi were similar to those with MDIe and MDIs. The oblique 45° load played an important role in dramatically increased average stress and strain in all bone-implant models. Mini dental implants with external or internal connections have similar stress distribution to single piece mini dental implants. In clinical situations, the three types of mini dental implant should exhibit the same behavior to chewing force.

  5. A finite element study on stress distribution of two different attachment designs under implant supported overdenture

    OpenAIRE

    El-Anwar, Mohamed I.; Yousief, Salah A.; Soliman, Tarek A.; Saleh, Mahmoud M.; Omar, Wael S.

    2015-01-01

    Objective: This study aimed to evaluate stress patterns generated within implant-supported mandibular overdentures retained by two different attachment types: ball and socket and locator attachments. Materials and methods: Commercial CAD/CAM and finite element analysis software packages were utilized to construct two 3D finite element models for the two attachment types. Unilateral masticatory compressive loads of 50, 100, and 150 N were applied vertically to the overdentures, parallel to ...

  6. Design and optimization of stress centralized MEMS vector hydrophone with high sensitivity at low frequency

    Science.gov (United States)

    Zhang, Guojun; Ding, Junwen; Xu, Wei; Liu, Yuan; Wang, Renxin; Han, Janjun; Bai, Bing; Xue, Chenyang; Liu, Jun; Zhang, Wendong

    2018-05-01

    A micro hydrophone based on piezoresistive effect, "MEMS vector hydrophone" was developed for acoustic detection application. To improve the sensitivity of MEMS vector hydrophone at low frequency, we reported a stress centralized MEMS vector hydrophone (SCVH) mainly used in 20-500 Hz. Stress concentration area was actualized in sensitive unit of hydrophone by silicon micromachining technology. Then piezoresistors were placed in stress concentration area for better mechanical response, thereby obtaining higher sensitivity. Static analysis was done to compare the mechanical response of three different sensitive microstructure: SCVH, conventional micro-silicon four-beam vector hydrophone (CFVH) and Lollipop-shaped vector hydrophone (LVH) respectively. And fluid-structure interaction (FSI) was used to analyze the natural frequency of SCVH for ensuring the measurable bandwidth. Eventually, the calibration experiment in standing wave field was done to test the property of SCVH and verify the accuracy of simulation. The results show that the sensitivity of SCVH has nearly increased by 17.2 dB in contrast to CFVH and 7.6 dB in contrast to LVH during 20-500 Hz.

  7. A hierarchical method for discrete structural topology design problems with local stress and displacement constraints

    DEFF Research Database (Denmark)

    Stolpe, Mathias; Stidsen, Thomas K.

    2007-01-01

    and then successively refined as needed. At each level of design mesh refinement, a neighbourhood optimization method is used to treat the problem considered. The non-convex topology design problems are equivalently reformulated as convex all-quadratic mixed 0-1 programs. This reformulation enables the use of methods...

  8. Electric Stress Computations for Designing a Novel Unibody Composite Cross-Arm Using Finite Element Method

    DEFF Research Database (Denmark)

    Jahangiri, Tohid; Wang, Qian; Bak, Claus Leth

    2017-01-01

    requirements in the design process of a nontraditional pylon. In this paper, ANSYS finite element software is used to calculate the electric field and potential distribution around and inside the fully composite pylon. Electric field criteria related to the design of composite cross-arms are reviewed...

  9. Multi-Focus Beamforming for Thermal Strain Imaging Using a Single Ultrasound Linear Array Transducer.

    Science.gov (United States)

    Nguyen, Man M; Ding, Xuan; Leers, Steven A; Kim, Kang

    2017-06-01

    Ultrasound-induced thermal strain imaging (TSI) has been used successfully to identify lipid- and water-based tissues in atherosclerotic plaques in some research settings. However, TSI faces several challenges to be realized in clinics. These challenges include motion artifacts and displacement tracking accuracy, as well as limited heating capability, which contributes to low thermal strain signal-to-noise ratio, and a limited field of view. Our goal was to address the challenge in heating tissue in TSI. Current TSI systems use separate heating and imaging transducers, which require physical alignment of the heating and imaging beams and result in a bulky setup that limits in vivo operation. We evaluated a new design for heating beams that can be implemented on a linear array imaging transducer and can provide improved heating area and efficiency as compared with previous implementations. The heating beams designed were implemented with a clinical linear array imaging transducer connected to a research ultrasound platform. In vitro experiments using tissue-mimicking phantoms with no blood flow revealed that the new design resulted in an effective heating area of approximately 0.85 cm 2 and a 0.3°C temperature rise in 2 s of heating, which compared well with in silico finite-element simulations. With the new heating beams, TSI was found to be able to detect a lipid-mimicking rubber inclusion with a diameter of 1 cm from the water-based gelatin background, with a strain contrast of 2.3 (+0.14% strain in the rubber inclusion and -0.06% strain in the gelatin background). Lastly, lipid-based tissue in a 1-cm-diameter human carotid endarterectomy (CEA) sample was identified in good agreement with histology. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  10. An ultrasonic fuel identification system for liquid metal cooled reactors resilient against multiple transducer failures

    International Nuclear Information System (INIS)

    Van-Dyck, Dries; Dierckx, Marc

    2013-06-01

    We describe a fuel assembly identification system developed for the MYRRHA reactor - a new multi-purpose flexible irradiation facility to replace the aging BR2. MYRRHA is a fast spectrum research reactor cooled with lead-bismuth eutectic (LBE) and conceived as an accelerator driven system capable of operating in sub-critical and critical modes. As liquid metal is opaque to visual light, the conventional optical fuel assembly identification system, as used by water cooled reactors, has to be replaced by a system not hindered by the opacity of the coolant. As already suggested in the late sixties, we use ultrasound for this purpose and present an encoding especially designed to enhance the robustness of the ultrasonic read-out. The encoding is based on notches of varying depth on the inflow nozzle of a fuel assembly. The depth of each notch is used to encode two bits and is measured by a dedicated transducer aligned over the notch. To increase the reliability of the fuel identification process, the identification number is protected by an error correcting code based on Hamming codes. We describe the ultrasonic system used to read out the vector of depths which is subsequently converted to a vector of bits. We explain the encoding of the twelve bit fuel identification numbers to a 22-bit error correcting code and discuss how Hamming decoding can be used to correct single bit errors, detect two bit errors or fill in the missing bits of a failing transducer. We also present a method based on solving a linear system over Boolean variables to (partially) reconstruct the fuel identification number in case multiple transducers fail. We show that the probability on full reconstruction is 100% for up to two transducer failures, 98% for three, 79% for four and 20% for five failing transducers. Finally, we present validation results in water and lead-bismuth eutectic for the differential measurement method used to measure the depth of the notches which form the basis for the

  11. Development of a stress sensor based on the piezoelectric lead zirconate titanate for impact stress measurement

    Science.gov (United States)

    Liu, Yiming; Xu, Bin; Li, Lifei; Li, Bing

    2012-04-01

    The measurement of stress of concrete structures under impact loading and other strong dynamic loadings is crucial for the monitoring of health and damage detection. Due to its main advantages including availability, extremely high rigidity, high natural frequency, wide measuring range, high stability, high reproducibility, high linearity and wide operating temperature range, piezoelectric (Lead Zirconate Titanate, PZT) ceramic materials has been a widely used smart material for both sensing and actuation for monitoring and control in engineering structures. In this paper, a kind of stress sensor based on piezoelectric ceramics for impact stress measuring of concrete structures is developed. Because the PZT is fragile, in order to employ it for the health monitoring of concrete structures, special handling and treatment should be taken to protect the PZT and to make it survive and work properly in concrete. The commercially available PZT patch with lead wires is first applied with an insulation coating to prevent water and moisture damage, and then is packaged by jacketing it by two small precasted cylinder concrete blocks with enough strength to form a smart aggregate (SA). The employed PZT patch has a dimension of 10mm x 10mm x 0.3mm. In order to calibrate the PZT based stress sensor for impact stress measuring, a dropping hammer was designed and calibration test on the sensitivity of the proposed transducer was carried out with an industry charge amplifier. The voltage output of the stress sensor and the impact force under different free falling heights and impact mass were recorded with a high sampling rate data acquisition system. Based on the test measurements, the sensibility of the PZT based stress sensor was determined. Results show that the output of the PZT based stress sensor is proportional to the stress level and the repeatability of the measurement is very good. The self-made piezoelectric stress sensor can be easily embedded in concrete and provide

  12. Tunable-angle wedge transducer for improved acoustophoretic control in a microfluidic chip

    DEFF Research Database (Denmark)

    Iranmanesh, I.; Barnkob, Rune; Bruus, Henrik

    2012-01-01

    We present a tunable-angle wedge ultrasound transducer for improved control of microparticle acoustophoresis in a microfluidic chip. The transducer is investigated by analyzing the pattern of aligned particles and induced acoustic energy density while varying the system geometry, transducer......-angle transducer are compared with the results from actuation by a standard planar transducer in order to decouple the influence from change in coupling angle and change in system geometry. We find in this work that the transducer coupling angle is the more important parameter compared to the concomitant change...

  13. Determination of the response time of pressure transducers using the direct method

    International Nuclear Information System (INIS)

    Perillo, S.R.P.

    1994-01-01

    The available methods to determine the response time of nuclear safety related pressure transducers are discussed, with emphasis to the direct method. In order to perform the experiments, a Hydraulic Ramp Generator was built. The equipment produces ramp pressure transients simultaneously to a reference transducer and to the transducer under test. The time lag between the output of the two transducers, when they reach a predetermined setpoint, is measured as the time delay of the transducer under test. Some results using the direct method to determine the time delay of pressure transducers (1 E Class Conventional) are presented. (author). 18 refs, 35 figs, 12 tabs

  14. Optimization of autonomous magnetic field sensor consisting of giant magnetoimpedance sensor and surface acoustic wave transducer

    KAUST Repository

    Li, Bodong

    2012-11-01

    This paper presents a novel autonomous thin film magnetic field sensor consisting of a tri-layer giant magnetoimpedance sensor and a surface acoustic wave transponder. Double and single electrode interdigital transducer (IDT) designs are employed and compared. The integrated sensor is fabricated using standard microfabrication technology. The results show the double electrode IDT has an advantage in terms of the sensitivity. In order to optimize the matching component, a simulation based on P-matrix is carried out. A maximum change of 2.4 dB of the reflection amplitude and a sensitivity of 0.34 dB/Oe are obtained experimentally. © 2012 IEEE.

  15. 2D-finite element stress analysis of NET first wall design

    International Nuclear Information System (INIS)

    Mukherjee, S.B.; Daenner, W.; Vieder, G.

    1984-01-01

    The 2D finite element (FE) method is applied for the NET first wall structure to compute the quasi-harmonic steady-state temperature distribution within the wall and to determine the nonlinear (elastic)-stresses under thermomechanical loads. Two different concepts for the wall structure, one having grooves and other one with plane wall, are investigated. The wall's support conditions, nonlinear material and thermal parameters are varied. The hydrostatic liquid lead pressure is also included. The computations are carried out using water as a coolant and the results are described. (author)

  16. Instantaneous input electrical power measurements of HITU transducer

    International Nuclear Information System (INIS)

    Karaboece, B; Guelmez, Y; Rajagapol, S; Shaw, A

    2011-01-01

    HITU (High Intensity Theraupetic Ultrasound) transducers are widely used in therapeutic ultrasound in medicine. The output ultrasonic power of HITU transducer can be measured in number of methods described in IEC 61161 standard [1]. New IEC standards specifically for measurement of HITU equipment are under development. The ultrasound power radiated from a transducer is dependent on applied input electrical voltage and current and consequently power. But, up to now, no standardised method has been developed and adopted for the input electrical power measurements. Hence, a workpackage was carried out for the establishment of such method in the frequency range of 1 to 3 MHz as a part of EURAMET EMRP Era-net plus 'External Beam Cancer Therapy' project. Several current shunts were developed and evaluated. Current measurements were also realized with Philips current probe and preamplifier at NPL and Agilent current probe at UME. In this paper, a method for the measurement of instantaneous electrical power delivered to a reactive ultrasound transducer in the required frequency range is explored.

  17. A capacitive ultrasonic transducer based on parametric resonance.

    Science.gov (United States)

    Surappa, Sushruta; Satir, Sarp; Levent Degertekin, F

    2017-07-24

    A capacitive ultrasonic transducer based on a parametric resonator structure is described and experimentally demonstrated. The transducer structure, which we call capacitive parametric ultrasonic transducer (CPUT), uses a parallel plate capacitor with a movable membrane as part of a degenerate parametric series RLC resonator circuit with a resonance frequency of f o . When the capacitor plate is driven with an incident harmonic ultrasonic wave at the pump frequency of 2f o with sufficient amplitude, the RLC circuit becomes unstable and ultrasonic energy can be efficiently converted to an electrical signal at f o frequency in the RLC circuit. An important characteristic of the CPUT is that unlike other electrostatic transducers, it does not require DC bias or permanent charging to be used as a receiver. We describe the operation of the CPUT using an analytical model and numerical simulations, which shows drive amplitude dependent operation regimes including parametric resonance when a certain threshold is exceeded. We verify these predictions by experiments with a micromachined membrane based capacitor structure in immersion where ultrasonic waves incident at 4.28 MHz parametrically drive a signal with significant amplitude in the 2.14 MHz RLC circuit. With its unique features, the CPUT can be particularly advantageous for applications such as wireless power transfer for biomedical implants and acoustic sensing.

  18. A capacitive ultrasonic transducer based on parametric resonance

    Science.gov (United States)

    Surappa, Sushruta; Satir, Sarp; Levent Degertekin, F.

    2017-07-01

    A capacitive ultrasonic transducer based on a parametric resonator structure is described and experimentally demonstrated. The transducer structure, which we call capacitive parametric ultrasonic transducer (CPUT), uses a parallel plate capacitor with a movable membrane as part of a degenerate parametric series RLC resonator circuit with a resonance frequency of fo. When the capacitor plate is driven with an incident harmonic ultrasonic wave at the pump frequency of 2fo with sufficient amplitude, the RLC circuit becomes unstable and ultrasonic energy can be efficiently converted to an electrical signal at fo frequency in the RLC circuit. An important characteristic of the CPUT is that unlike other electrostatic transducers, it does not require DC bias or permanent charging to be used as a receiver. We describe the operation of the CPUT using an analytical model and numerical simulations, which shows drive amplitude dependent operation regimes including parametric resonance when a certain threshold is exceeded. We verify these predictions by experiments with a micromachined membrane based capacitor structure in immersion where ultrasonic waves incident at 4.28 MHz parametrically drive a signal with significant amplitude in the 2.14 MHz RLC circuit. With its unique features, the CPUT can be particularly advantageous for applications such as wireless power transfer for biomedical implants and acoustic sensing.

  19. Analysis of the conical piezoelectric acoustic emission transducer

    Czech Academy of Sciences Publication Activity Database

    Červená, Olga; Hora, Petr

    2008-01-01

    Roč. 2, č. 1 (2008), s. 13-24 ISSN 1802-680X R&D Projects: GA ČR GA101/06/1689 Institutional research plan: CEZ:AV0Z20760514 Keywords : acoustic emission * conical transducer * FEM Subject RIV: BI - Acoustics

  20. The Current State of Silicone-Based Dielectric Elastomer Transducers

    DEFF Research Database (Denmark)

    Madsen, Frederikke Bahrt; Daugaard, Anders Egede; Hvilsted, Søren

    2016-01-01

    Silicone elastomers are promising materials for dielectric elastomer transducers (DETs) due to their superior properties such as high efficiency, reliability and fast response times. DETs consist of thin elastomer films sandwiched between compliant electrodes, and they consti- tute an interesting...

  1. Simulating Capacitive Micromachined Ultrasonic Transducers (CMUTs) using Field II

    DEFF Research Database (Denmark)

    Bæk, David; Oralkan, Omer; Kupnik, Mario

    2010-01-01

    which it calculates the SIR responses. The program features predefined models for classical transducer geometries, but currently none for the fast advancing CMUTs. This work addresses the assumptions required for modeling CMUTs with Field II. It is shown that rectangular array elements, populated...

  2. High Temperature Ultrasonic Transducers : Material Selection and Testing

    Science.gov (United States)

    Bar-Cohen, Yoseph; Bruno, Alessandro

    2012-01-01

    The task of my two-months internship was to test different materials to be used to build an high temperature transducer, to develop some prototypes and to test their performance, to assess the reliability of commercial product rated for such a temperature, as well as to collaborate in developing the signal processing code to measure the condensed water levels.

  3. Air-borne radiation from bone conduction transducers.

    Science.gov (United States)

    Lightfoot, G R

    1979-05-01

    The relative magnitudes of air-borne radiation and mechanical vibration from three types of bone conduction transducer have been measured. The study suggests that the presence of excess air-borne radiation can lead to the observation of a false air-bone gap in audiometry. Some methods of overcoming this effect are considered.

  4. Transducer frequency response variations investigated by time reversal calibration

    Czech Academy of Sciences Publication Activity Database

    Kober, Jan; Převorovský, Zdeněk

    2016-01-01

    Roč. 26, č. 2 (2016), A16-A16 ISSN 1213-3825. [Europen Conference on Acoustic Emission Testing /32./. 07.09.2016-09.09.2016, Praha] Institutional support: RVO:61388998 Keywords : calibration * time reversal * transducer * frequency response Subject RIV: BI - Acoustic s

  5. Neutron Irradiation Tests of Pressure Transducers in Liquid Helium

    CERN Document Server

    Amand, J F; Casas-Cubillos, J; Thermeau, J P

    1999-01-01

    The superconducting magnets of the future Large Hadron Collider (LHC) at CERN will operate in pressurised superfluid helium (1 bar, 1.9 K). About 500 pressure transducers will be placed in the liquid helium bath for monitoring the filling and the pressure transients after resistive transitions. Their precision must remain better than 100 mbar at pressures below 2 bar and better than 5% for higher pressures (up to 20 bar), with temperatures ranging from 1.8 K to 300 K. All the tested transducers are based on the same principle: the fluid or gas is separated from a sealed reference vacuum by an elastic membrane; its deformation indicates the pressure. The transducers will be exposed to high neutron fluence (2 kGy, 1014 n/cm2 per year) during the 20 years of machine operation. This irradiation may induce changes both on the membranes characteristics (leakage, modification of elasticity) and on gauges which measure their deformations. To investigate these effects and select the transducer to be used in the LHC, a...

  6. Instantaneous input electrical power measurements of HITU transducer

    Energy Technology Data Exchange (ETDEWEB)

    Karaboece, B; Guelmez, Y [Tuebitak Ulusal Metroloji Enstituesue (UME), P.K. 54 41470 Gebze-Kocaeli (Turkey); Rajagapol, S; Shaw, A, E-mail: baki.karaboce@ume.tubitak.gov.t [National Physical Laboratory (NPL), Hampton Road, Teddington TW11 0LW (United Kingdom)

    2011-02-01

    HITU (High Intensity Theraupetic Ultrasound) transducers are widely used in therapeutic ultrasound in medicine. The output ultrasonic power of HITU transducer can be measured in number of methods described in IEC 61161 standard [1]. New IEC standards specifically for measurement of HITU equipment are under development. The ultrasound power radiated from a transducer is dependent on applied input electrical voltage and current and consequently power. But, up to now, no standardised method has been developed and adopted for the input electrical power measurements. Hence, a workpackage was carried out for the establishment of such method in the frequency range of 1 to 3 MHz as a part of EURAMET EMRP Era-net plus 'External Beam Cancer Therapy' project. Several current shunts were developed and evaluated. Current measurements were also realized with Philips current probe and preamplifier at NPL and Agilent current probe at UME. In this paper, a method for the measurement of instantaneous electrical power delivered to a reactive ultrasound transducer in the required frequency range is explored.

  7. Power doppler 'blanching' after the application of transducer pressure

    International Nuclear Information System (INIS)

    Joshua, F.; Edmonds, J.; Lassere, M.; De Carle, R.; Rayment, M.; Bryant, C.; Shnier, R.

    2005-01-01

    The aim of this study was to determine if transducer pressure modifies power Doppler assessments of rheumatoid arthritis synovium at the metacarpophalangeal joints and metatarsophalangeal joints. Five rheumatoid arthritis patients of varying degrees of 'disease activity' and damage were assessed with power Doppler ultrasound scanning of the dominant hand second to fifth metacarpophalangeal joints. Two rheumatoid arthritis patients had their dominant foot first to fifth metatarsophalangeal joints assessed with power Doppler ultrasound. Ultrasonography was performed with a high frequency transducer (14 MHz) with a colour mode frequency of 10 Mhz, and a standard colour box and gain. In the joint that showed the highest power Doppler signal, an image was made. A further image was taken after transducer pressure was applied. In all patients, there was increased flow to at least one joint. After pressure was applied, power Doppler signal intensity markedly reduced in all images and in some there was no recordable power Doppler signal. Increased transducer pressure can result in a marked reduction or obliteration in power Doppler signal. This power Doppler 'blanching' shows the need for further studies to evaluate sources of error and standardization before power Doppler ultrasound becomes a routine measure of 'disease activity' in rheumatoid arthritis. Copyright (2005) Blackwell Science Pty Ltd

  8. Electrical capacity and resistance determination of emitting electric transducer

    International Nuclear Information System (INIS)

    Alba Fernandez, J.; Ramis Soriano, J.

    2000-01-01

    In this work we calculate the electrical resistance and capacity of emitting electric transducer, which is mainly formed, in direct relationship with its properties, by a ceramic capacitor. Our aim is to motivate the students with an attractive element in order to carry out traditional measurements of the charge and discharge transients of a capacitor, implementing high resistance setups. (Author) 5 refs

  9. Enhancing endosomal escape of transduced proteins by photochemical internalisation.

    Directory of Open Access Journals (Sweden)

    Kevin Mellert

    Full Text Available Induced internalisation of functional proteins into cultured cells has become an important aspect in a rising number of in vitro and in vivo assays. The endo-lysosomal entrapment of the transduced proteins remains the major problem in all transduction protocols. In this study we compared the efficiency, cytotoxicity and protein targeting of different commercially available transduction reagents by transducing a well-studied fluorescently labelled protein (Atto488-bovine serum albumin into cultured human sarcoma cells. The amount of internalised protein and toxicity differed between the different reagents, but the percentage of transduced cells was consistently high. Furthermore, in all protocols the signals of the transduced Atto488-BSA were predominantly punctual consistent with an endosomal localisation. To overcome the endosomal entrapment, the transduction protocols were combined with a photochemical internalisation (PCI treatment. Using this combination revealed that an endosomal disruption is highly effective in cell penetrating peptide (CPP mediated transduction, whereas lipid-mediated transductions lead to a lower signal spreading throughout the cytosol. No change in the signal distribution could be achieved in treatments using non-lipid polymers as a transduction reagent. Therefore, the combination of protein transduction protocols based on CPPs with the endosomolytic treatment PCI can facilitate protein transduction experiments in vitro.

  10. Enhancing endosomal escape of transduced proteins by photochemical internalisation.

    Science.gov (United States)

    Mellert, Kevin; Lamla, Markus; Scheffzek, Klaus; Wittig, Rainer; Kaufmann, Dieter

    2012-01-01

    Induced internalisation of functional proteins into cultured cells has become an important aspect in a rising number of in vitro and in vivo assays. The endo-lysosomal entrapment of the transduced proteins remains the major problem in all transduction protocols. In this study we compared the efficiency, cytotoxicity and protein targeting of different commercially available transduction reagents by transducing a well-studied fluorescently labelled protein (Atto488-bovine serum albumin) into cultured human sarcoma cells. The amount of internalised protein and toxicity differed between the different reagents, but the percentage of transduced cells was consistently high. Furthermore, in all protocols the signals of the transduced Atto488-BSA were predominantly punctual consistent with an endosomal localisation. To overcome the endosomal entrapment, the transduction protocols were combined with a photochemical internalisation (PCI) treatment. Using this combination revealed that an endosomal disruption is highly effective in cell penetrating peptide (CPP) mediated transduction, whereas lipid-mediated transductions lead to a lower signal spreading throughout the cytosol. No change in the signal distribution could be achieved in treatments using non-lipid polymers as a transduction reagent. Therefore, the combination of protein transduction protocols based on CPPs with the endosomolytic treatment PCI can facilitate protein transduction experiments in vitro.

  11. A Multiscale Adaptive Mesh Refinement Approach to Architectured Steel Specification in the Design of a Frameless Stressed Skin Structure

    DEFF Research Database (Denmark)

    Nicholas, Paul; Stasiuk, David; Nørgaard, Esben

    2015-01-01

    This paper describes the development of a modelling approach for the design and fabrication of an incrementally formed, stressed skin metal structure. The term incremental forming refers to a progression of localised plastic deformation to impart 3D form onto a 2D metal sheet, directly from 3D...... design data. A brief introduction presents this fabrication concept, as well as the context of structures whose skin plays a significant structural role. Existing research into ISF privileges either the control of forming parameters to minimise geometric deviation, or the more accurate measurement...... of the impact of the forming process at the scale of the grain. But to enhance structural performance for architectural applications requires that both aspects are considered synthetically. We demonstrate a mesh-based approach that incorporates critical parameters at the scales of structure, element...

  12. Moessbauer effect: on the application of digital synthesis in order tosynchronize the frequency of the function generator of the transducer with the frequency of the channel opening commands, in 'multiscale' operation

    International Nuclear Information System (INIS)

    Carrilho, R.J.; Marins, J.E.R.

    1981-01-01

    A new instrument for the channel opening command, synchronized to the movement, is designed, developed and produced, together with a new and complete amplifier for the transducer activation. (L.C.) [pt

  13. Influences of internal tapered abutment designs on bone stresses around a dental implant: three-dimensional finite element method with statistical evaluation.

    Science.gov (United States)

    Chu, Chun-Ming; Huang, Heng-Li; Hsu, Jui-Ting; Fuh, Lih-Jyh

    2012-01-01

    The aim of this study is to determine the effects of various designs of internal tapered abutment joints on the stress induced in peri-implant crestal bone by using the three-dimensional finite element method and statistical analyses. Thirty-six models with various internal tapered abutment-implant interface designs including different abutment diameters (3.0, 3.5, and 4.0 mm), connection depths (4, 6, and 8 mm), and tapers (2°, 4°, 6°, and 8°) were constructed. A force of 170 N was applied to the top surface of the abutment either vertically or 45° obliquely. The maximum von Mises bone-stress values in the crestal bone surrounding the implant were statistically analyzed using analysis of variance. In addition, patterns of bone stress around the implant were examined. The results demonstrate that a smaller abutment diameter and a longer abutment connection significantly reduced the bone stresses (P implant interfaced connection was more parallel, bone stresses under vertical loading were less (P = 0.0002), whereas the abutment taper did not show significant effects on bone stresses under oblique loading (P = 0.83). Bone stresses were mainly influenced by the abutment diameter, followed by the abutment connection depth and the abutment taper. For an internal tapered abutment design, it was suggested that a narrower and deeper abutment-implant interface produced the biomechanical advantage of reducing the stress concentration in the crestal region around an implant.

  14. Design and development of a new magnetic sensor for stress monitoring and annihilation/control in steels

    Science.gov (United States)

    Mangiorou, E.

    2017-12-01

    This paper describes a new method and apparatus for monitoring the distribution of the hydraulic stresses (type stresses I) and the residual stresses (type stresses II and III) in ferromagnetic steels within the elastic region and plastic deformation region, determining the deforming step them and use them for elimination and / or control of the stresses in the steel.

  15. A single-input, single-output electromagnetically-transduced microresonator array

    International Nuclear Information System (INIS)

    Sabater, A B; Hunkler, A G; Rhoads, J F

    2014-01-01

    Resonant microsystems have found broad applicability in environmental and inertial sensing, signal filtering and timing applications. Despite this breadth in utility, a common constraint on these devices is throughput, or the total amount of information that they can process. In recent years, elastically-coupled arrays of microresonators have been used to increase the throughput in sensing contexts, but these arrays are often more complicated to design than their isolated counterparts, due to the potential for collective behaviors (such as vibration localization) to arise. An alternative solution to the throughput constraint is to use arrays of electromagnetically-transduced microresonators. These arrays can be designed such that the mechanical resonances are spaced far apart and the mechanical coupling between the microresonators is insignificant. Thus, when the entire array is actuated and sensed, a resonance in the electrical response can be directly correlated to a specific microresonator vibrating, as collective behaviors have been avoided. This work details the design, analysis and experimental characterization of an electromagnetically-transduced microresonator array in both low- and atmospheric-pressure environments, and demonstrates that the system could be used as a sensor in ambient conditions. While this device has direct application as a resonant-based sensor that requires only a single source and measurement system to track multiple resonances, with simple modification, this array could find uses in tunable oscillator and frequency multiplexing contexts. (paper)

  16. Standard practice for determining damage-Based design Stress for fiberglass reinforced plastic (FRP) materials using acoustic emission

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This practice details procedures for establishing the direct stress and shear stress damage-based design values for use in the damage-based design criterion for materials to be used in FRP vessels and other composite structures. The practice uses data derived from acoustic emission examination of four-point beam bending tests and in-plane shear tests (see ASME Section X, Article RT-8). 1.2 The onset of lamina damage is indicated by the presence of significant acoustic emission during the reload portion of load/reload cycles. "Significant emission" is defined with historic index. 1.3 Units - The values stated in inch-pound units are to be regarded as standard. The values given in brackets are mathematical conversions to SI units which are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health pr...

  17. Stress relaxation and estimation of activation volume in a ...

    Indian Academy of Sciences (India)

    Unknown

    ). The testing was carried out in displacement control for stress relaxation testing at a strain rate of 3%/min. An active capacitor transducer measured the displacement of specimen with a sensitivity of 367 µm/V. 3. Results and discussion.

  18. A process chain for integrating piezoelectric transducers into aluminum die castings to generate smart lightweight structures

    Science.gov (United States)

    Stein, Stefan; Wedler, Jonathan; Rhein, Sebastian; Schmidt, Michael; Körner, Carolin; Michaelis, Alexander; Gebhardt, Sylvia

    The application of piezoelectric transducers to structural body parts of machines or vehicles enables the combination of passive mechanical components with sensor and actuator functions in one single structure. According to Herold et al. [1] and Staeves [2] this approach indicates significant potential regarding smart lightweight construction. To obtain the highest yield, the piezoelectric transducers need to be integrated into the flux of forces (load path) of load bearing structures. Application in a downstream process reduces yield and process efficiency during manufacturing and operation, due to the necessity of a subsequent process step of sensor/actuator application. The die casting process offers the possibility for integration of piezoelectric transducers into metal structures. Aluminum castings are particularly favorable due to their high quality and feasibility for high unit production at low cost (Brunhuber [3], Nogowizin [4]). Such molded aluminum parts with integrated piezoelectric transducers enable functions like active vibration damping, structural health monitoring or energy harvesting resulting in significant possibilities of weight reduction, which is an increasingly important driving force of automotive and aerospace industry (Klein [5], Siebenpfeiffer [6]) due to increasingly stringent environmental protection laws. In the scope of those developments, this paper focuses on the entire process chain enabling the generation of lightweight metal structures with sensor and actuator function, starting from the manufacturing of piezoelectric modules over electrical and mechanical bonding to the integration of such modules into aluminum (Al) matrices by die casting. To achieve this challenging goal, piezoceramic sensors/actuator modules, so-called LTCC/PZT modules (LPM) were developed, since ceramic based piezoelectric modules are more likely to withstand the thermal stress of about 700 °C introduced by the casting process (Flössel et al., [7]). The

  19. Contribution to the development and the modelling of an ultrasonic conformable phased array transducer for the contact inspection of 3D complex geometry components; Contribution au developpement et a la modelisation d'un traducteur ultrasonore multielements conformable pour l'inspection au contact de composants a geometrie complexe 3D

    Energy Technology Data Exchange (ETDEWEB)

    Guedes, O

    2005-04-15

    With the difficulties encountered for the exploration of complex shape surfaces, particularly in nuclear industry, the ultrasonic conformable phased array transducer allows a non destructive evaluation of parts with 3D complex parts. For this, one can use the Smart Contact Transducer principle to generate an ultrasonic field by adaptive dynamic focalisation, with a matrix array composed of independent elements moulded in a soft resin. This work deals with the electro-acoustic conception, with the realization of such a prototype and with the study of it's mechanical and acoustic behaviour. The array design is defined using a radiation model adapted to the simulation of contact sources on a free surface. Once one have defined the shape of the radiating elements, a vibratory analysis using finite elements method allows the determination of the emitting structure with 1-3 piezocomposite, witch leads to the realization of emitting-receiving elements. With the measurement of the field transmitted by such elements, we deduced new hypothesis to change the model of radiation. Thus one can take into account normal and tangential stresses calculated with finite element modelling at the interface between the element and the propagation medium, to use it with the semi-analytical model. Some vibratory phenomena dealing with fluid coupling of contact transducers have been studied, and the prediction of the transverse wave radiation profile have been improved. The last part of this work deals with the realization of the first prototype of the conformable phased array transducer. For this a deformation measuring system have been developed, to determine the position of each element on real time with the displacement of the transducer on complex shape surfaces. With those positions, one can perform the calculation of the a delay law intended for the adaptive dynamic focusing of the desired ultrasonic field. The conformable phased array transducer have been characterized in

  20. Comparative Evaluation of Stress Distribution in Experimentally Designed Nickel-titanium Rotary Files with Varying Cross Sections: A Finite Element Analysis.

    Science.gov (United States)

    Basheer Ahamed, Shadir Bughari; Vanajassun, Purushothaman Pranav; Rajkumar, Kothandaraman; Mahalaxmi, Sekar

    2018-04-01

    Single cross-sectional nickel-titanium (NiTi) rotary instruments during continuous rotations are subjected to constant and variable stresses depending on the canal anatomy. This study was intended to create 2 new experimental, theoretic single-file designs with combinations of triple U (TU), triangle (TR), and convex triangle (CT) cross sections and to compare their bending stresses in simulated root canals with a single cross-sectional instrument using finite element analysis. A 3-dimensional model of the simulated root canal with 45° curvature and NiTi files with 5 cross-sectional designs were created using Pro/ENGINEER Wildfire 4.0 software (PTC Inc, Needham, MA) and ANSYS software (version 17; ANSYS, Inc, Canonsburg, PA) for finite element analysis. The NiTi files of 3 groups had single cross-sectional shapes of CT, TR, and TU designs, and 2 experimental groups had a CT, TR, and TU (CTU) design and a TU, TR, and CT (UTC) design. The file was rotated in simulated root canals to analyze the bending stress, and the von Mises stress value for every file was recorded in MPa. Statistical analysis was performed using the Kruskal-Wallis test and the Bonferroni-adjusted Mann-Whitney test for multiple pair-wise comparison with a P value <.05 (95 %). The maximum bending stress of the rotary file was observed in the apical third of the CT design, whereas comparatively less stress was recorded in the CTU design. The TU and TR designs showed a similar stress pattern at the curvature, whereas the UTC design showed greater stress in the apical and middle thirds of the file in curved canals. All the file designs showed a statistically significant difference. The CTU designed instruments showed the least bending stress on a 45° angulated simulated root canal when compared with all the other tested designs. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.