WorldWideScience

Sample records for stress radiographic analysis

  1. Development of a micrometre-scale radiographic measuring method for residual stress analysis

    International Nuclear Information System (INIS)

    Moeller, D.

    1999-01-01

    The radiographic method described uses micrometre X-ray diffraction for high-resolution residual stress analysis in single crystals. The focus is on application of two x-ray optics (glass capillaries) for shaping a sufficiently fine and intensive primary beam. Due to application of a proper one-grain measuring and analysis method, the resolution results are applicable to the characteristic grain sizes of many materials. (orig.) [de

  2. Radiographic enhancement and analysis system

    International Nuclear Information System (INIS)

    Schlosser, M.S.

    1981-01-01

    Radiographic image enhancement and analysis techniques are discussed as they apply to nondestructive inspection. A system is described which has been developed to enhance and quantitatively evaluate radiographic images using digital computer techniques. Some examples of typical applications are also presented as an introduction to this new inspection technique. (author)

  3. Occupational stress and its predictors in radiographers

    Energy Technology Data Exchange (ETDEWEB)

    Rutter, D.R. [Centre for Research in Health Behaviour, Department of Psychology, University of Kent, Keynes College, Canterbury CT2 7NP (United Kingdom)], E-mail: d.r.rutter@kent.ac.uk; Lovegrove, M.J. [Department of Allied Health Professions, London South Bank University, London SE1 0AA (United Kingdom)

    2008-05-15

    Purpose: The purpose of this study was to establish the level of occupational stress in UK NHS radiographers, and to examine its causes. A total of more than 1600 radiographers sampled nationally completed a postal questionnaire. Four groups were represented - mammography, diagnostics, radiotherapy, and ultrasound - and both junior staff and superintendents were examined. Method: The questionnaire measured role ambiguity, role conflict, work problems, social support from colleagues, and perceived stress. Results: Levels of perceived stress were high in all four groups. The mean was significantly lower in the mammography group than the others, however, and junior staff reported lower levels than superintendents. Role ambiguity, role conflict and work problems all contributed significantly to stress, but the effects were sometimes buffered by social support from colleagues. Conclusion: The implications of the findings are discussed for theory and for policy and practice: occupational stress was predicted by intrinsic features of the job; the levels were similar to those reported by other NHS professionals; and the pattern of findings suggests possible ways to intervene to reduce it.

  4. Occupational stress and its predictors in radiographers

    International Nuclear Information System (INIS)

    Rutter, D.R.; Lovegrove, M.J.

    2008-01-01

    Purpose: The purpose of this study was to establish the level of occupational stress in UK NHS radiographers, and to examine its causes. A total of more than 1600 radiographers sampled nationally completed a postal questionnaire. Four groups were represented - mammography, diagnostics, radiotherapy, and ultrasound - and both junior staff and superintendents were examined. Method: The questionnaire measured role ambiguity, role conflict, work problems, social support from colleagues, and perceived stress. Results: Levels of perceived stress were high in all four groups. The mean was significantly lower in the mammography group than the others, however, and junior staff reported lower levels than superintendents. Role ambiguity, role conflict and work problems all contributed significantly to stress, but the effects were sometimes buffered by social support from colleagues. Conclusion: The implications of the findings are discussed for theory and for policy and practice: occupational stress was predicted by intrinsic features of the job; the levels were similar to those reported by other NHS professionals; and the pattern of findings suggests possible ways to intervene to reduce it

  5. Digital image analysis of NDT radiographs

    International Nuclear Information System (INIS)

    Graeme, W.A. Jr.; Eizember, A.C.; Douglass, J.

    1989-01-01

    Prior to the introduction of Charge Coupled Device (CCD) detectors the majority of image analysis performed on NDT radiographic images was done visually in the analog domain. While some film digitization was being performed, the process was often unable to capture all the usable information on the radiograph or was too time consuming. CCD technology now provides a method to digitize radiographic film images without losing the useful information captured in the original radiograph in a timely process. Incorporating that technology into a complete digital radiographic workstation allows analog radiographic information to be processed, providing additional information to the radiographer. Once in the digital domain, that data can be stored, and fused with radioscopic and other forms of digital data. The result is more productive analysis and management of radiographic inspection data. The principal function of the NDT Scan IV digital radiography system is the digitization, enhancement and storage of radiographic images

  6. Occupational stress among radiographers: the impact of sonagraphy ...

    African Journals Online (AJOL)

    Sonography responsibility on radiographers did not have any significant effect on psychosocial stress. A balance in the extended role could aid efficiency in service delivery while improving the social strength of the individual. Keywords: Occupational stress; radiographers; sonographers. Internet Journal of Medical Update ...

  7. Relationship between stress ankle radiographs and injured ligaments on MRI

    International Nuclear Information System (INIS)

    Lee, Kyoung Min; Chung, Chin Youb; Chung, Myung Ki; Won, Sung Hun; Lee, Seung Yeol; Park, Moon Seok; Kwon, Soon-Sun

    2013-01-01

    This study was performed to investigate the relationship between the injured lateral ankle ligaments on MRI and stress ankle radiographs. Two hundred and twenty-nine consecutive patients (mean age 35.5 years, SD 14.6 years; 136 males and 93 females) that underwent ankle stress radiographs and MRI for lateral ankle instability were included. Tibiotalar tilt angle and anterior translation of talus were measured on stress ankle radiographs. Degree of lateral ligaments (anterior talofibular, calcaneofibular, and posterior talofibular) and deltoid ligament injuries were evaluated and scored as intact (0), partial injury (1), and complete injury (2) on MR images. Effusion of ankle joint was also recorded. The effects of gender, age, injuries of ligaments, and ankle joint effusion on stress radiographs were statistically analyzed. Gender (p = 0.010), age (p = 0.020), and anterior talofibular ligament (ATFL) injury (p < 0.001) were the factors significantly affecting tibiotalar tilt angle. Posterior talofibular ligament (PTFL) injury (p = 0.014) was found to be the only significant factor affecting the anterior translation on the anterior drawer radiographs. ATFL injury and PTFL injury on MRI significantly affected tibiotalar tilt angle and anterior drawer on stress radiographs. Other factors, such as age and gender, need to be considered in evaluating radiographic lateral ankle instability. (orig.)

  8. Radiographic evaluation of coxofemoral joint laxity in dogs part I: New stress-radiographic positioning techniques

    International Nuclear Information System (INIS)

    Phiwipha Kamonrat; Duangdaun Kaenkangploo

    2002-01-01

    Two new stress-radiographic positioning techniques, namely 60 deg and 90 deg stress techniques, were introduced for quantifying hip joint laxity in dogs. The comparative characteristics and efficiency of these new techniques with angled hindlimbs were evaluated relative to the standard hip-extended radiographic technique. Forty, healthy, mongrel dogs with normal hip joint conformation were anesthetized and placed in dorsal recumbency before 3 radiograhps of the standard, 60 deg , and 90 deg stress techniques were taken. For the 60 deg stress technique, hindlimbs were extended in parallel to each other at 60 deg angled to the table top and stifles were slightly rotated inward, femoral heads were manually pushed in a craniodorsal direction during exposure. For the 90 deg stress technique, femurs were positioned perpendicular to the table top, stifles were 90 deg flexed and adducted and femoral heads were manually pushed in a craniodorsal direction during exposure. The subluxation index (SI) and dorsolateral subluxation score (DLS score) were calculated from 3 radiographic views for both hip joints to quantitate the relative degree of joint laxity. Results of the study indicated that the 60 deg (SI = 0.20+-0.045, DLS score = 62.5+-7.96 percent) and 90 deg (SI = 0.23+-0.044, DLS score = 61.2+-9.47 percent) stress-radiographs yielded significantly (p0.001) higher degree of hip joint laxity than the standard technique (SI)

  9. incidence of occupational stress among medical radiographers

    African Journals Online (AJOL)

    Job satisfaction rating was 61.3% and anxiety level was 45.3%. This study has provided a baseline stress level and prevalence among ... theoretical terms predisposes the individual to increased ... checked, burnout ensures. Burnout is an individual's reaction to chronic stress .... neurovegetative functioning of the mental but.

  10. Job stress and job satisfaction of physicians, radiographers, nurses and physicists working in radiotherapy: a multicenter analysis by the DEGRO Quality of Life Work Group

    Directory of Open Access Journals (Sweden)

    Bölling Tobias

    2009-02-01

    Full Text Available Abstract Background Ongoing changes in cancer care cause an increase in the complexity of cases which is characterized by modern treatment techniques and a higher demand for patient information about the underlying disease and therapeutic options. At the same time, the restructuring of health services and reduced funding have led to the downsizing of hospital care services. These trends strongly influence the workplace environment and are a potential source of stress and burnout among professionals working in radiotherapy. Methods and patients A postal survey was sent to members of the workgroup "Quality of Life" which is part of DEGRO (German Society for Radiooncology. Thus far, 11 departments have answered the survey. 406 (76.1% out of 534 cancer care workers (23% physicians, 35% radiographers, 31% nurses, 11% physicists from 8 university hospitals and 3 general hospitals completed the FBAS form (Stress Questionnaire of Physicians and Nurses; 42 items, 7 scales, and a self-designed questionnaire regarding work situation and one question on global job satisfaction. Furthermore, the participants could make voluntary suggestions about how to improve their situation. Results Nurses and physicians showed the highest level of job stress (total score 2.2 and 2.1. The greatest source of job stress (physicians, nurses and radiographers stemmed from structural conditions (e.g. underpayment, ringing of the telephone a "stress by compassion" (e.g. "long suffering of patients", "patients will be kept alive using all available resources against the conviction of staff". In multivariate analyses professional group (p In multivariate analyses "professional group" (p = 0.006 and "vocational experience" (p = 0.036 were associated with job satisfaction (cancer care workers with Conclusion Current workplace environments have a negative impact on stress levels and the satisfaction of radiotherapy staff. Identification and removal of the above-mentioned critical

  11. Transfer function analysis of radiographic imaging systems

    International Nuclear Information System (INIS)

    Metz, C.E.; Doi, K.

    1979-01-01

    The theoretical and experimental aspects of the techniques of transfer function analysis used in radiographic imaging systems are reviewed. The mathematical principles of transfer function analysis are developed for linear, shift-invariant imaging systems, for the relation between object and image and for the image due to a sinusoidal plane wave object. The other basic mathematical principle discussed is 'Fourier analysis' and its application to an input function. Other aspects of transfer function analysis included are alternative expressions for the 'optical transfer function' of imaging systems and expressions are derived for both serial and parallel transfer image sub-systems. The applications of transfer function analysis to radiographic imaging systems are discussed in relation to the linearisation of the radiographic imaging system, the object, the geometrical unsharpness, the screen-film system unsharpness, other unsharpness effects and finally noise analysis. It is concluded that extensive theoretical, computer simulation and experimental studies have demonstrated that the techniques of transfer function analysis provide an accurate and reliable means for predicting and understanding the effects of various radiographic imaging system components in most practical diagnostic medical imaging situations. (U.K.)

  12. Radiographic and Clinical Analysis of Lateral Epicondylitis.

    Science.gov (United States)

    Shillito, Matthew; Soong, Maximillian; Martin, Nicholas

    2017-06-01

    The literature suggests that radiographs may be unnecessary in the initial evaluation of lateral epicondylitis because treatment is rarely altered as a result of the radiographic findings. The most commonly reported radiographic finding is calcification at the lateral epicondyle. Our goal was to perform a quantitative and qualitative analysis of this finding to determine its importance and possible relationship with various clinical factors and patient-reported measures. All patients diagnosed with lateral epicondylitis by a single surgeon during a 5-year period were retrospectively reviewed. Age, sex, laterality, hand dominance, pain visual analog scale, duration of symptoms, Quick-Disability of the Arm, Shoulder, and Hand questionnaire score, and history of steroid injection were recorded. Calcifications on standard elbow radiographs, acquired digitally and viewed at 200% magnification on a 24-inch monitor, were characterized by size and relationship with the lateral epicondyle. We reviewed 245 patients diagnosed with lateral epicondylitis. A total of 115 elbows (47%) demonstrated lateral epicondyle calcifications. Patients with and without calcifications were similar with regard to clinical factors, as were patients with larger or smaller lesions. Eighty-five elbows (35%) had additional radiographic findings. Treatment was not altered by the radiographic findings in any case. Lateral epicondyle calcifications are much more common in lateral epicondylitis than previously reported, possibly owing to modern digital radiography and magnification, although they do not appear to be related to clinical factors including patient-reported measures. Thus, patients and surgeons should be careful to avoid overinterpretation of such findings. Although radiographs may be helpful in ruling out additional pathology, we did not find other clinically important contributions to the initial evaluation and management of this condition, and thus we do not recommend their routine use

  13. Radiographic analysis of shoulder anatomical arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Merolla, Giovanni [Unit of Shoulder and Elbow Surgery, ' D. Cervesi' Hospital, L. Van Beethoven 46 Street, 47841 Cattolica (Italy)], E-mail: gmerolla@shouldertech.it; Di Pietto, Francesco; Romano, Stefania [Department of Diagnostic Imaging, ' A. Cardarelli' Hospital, Naples (Italy); Paladini, Paolo; Campi, Fabrizio; Porcellini, Giuseppe [Unit of Shoulder and Elbow Surgery, ' D. Cervesi' Hospital, L. Van Beethoven 46 Street, 47841 Cattolica (Italy)

    2008-10-15

    Arthroplasty is the standard treatment for advanced shoulder osteoarthritis. Modern prostheses designs have modular features whose size, shaft/head and body morphology can be adjusted. Total Shoulder Arthroplasty (TSA) provides better results. A complete X-ray follow-up is essential to assess the results and evaluate the survival rates of a shoulder prosthesis. Antero-posterior at 40 deg. in both internal and external rotation (true AP view) and axillary view are recommended to assess the following parameters: orientation and translation of the humeral component, offset, size and height of the humeral head, acromio-humeral distance, distribution and fixation of the cement, stress shielding and cortical resorption, radiolucent lines, subsidence and tilt, glenoid wear and 'bone stock', prostheses instability, glenoid component shift. Shoulder hemiarthroplasty can lead to glenoid wear; the true AP film at 40 deg. of internal rotation provides the best profile of gleno-humeral joint to depict glenoid erosion. Shift of the glenoid component in TSA is identified as tilting or medial migration on true AP and axillary views in the early postoperative period (1-2 months) and at minimum of 2 years. An exhaustive radiographic analysis remains essential to monitor the prosthetic implant and detect early and late complications or risk factors of prosthetic loosening.

  14. Stress radiographs in the evaluation of degenerative femorotibial joint disease

    Energy Technology Data Exchange (ETDEWEB)

    Tallroth, K.; Lindholm, T.S.

    1987-11-01

    Thirty-eight osteoarthrotic knees were examined to assess the widths of the femorotibial joint spaces. Radiographs were exposed with the patient lying, in a standing position, and with an adduction and abduction force. Forced compression of the osteoarthrotic joint compartment caused, on average, 18% greater narrowing than when loading it in the standing position. Compared to the joint space at rest, the non-weight-bearing compartment widened by 16% in the standing position and narrowed by 20% when stress was applied. Furthermore, the results showed an increase in laxity proportional to the degree of arthrosis. Stress radiographs significantly display the real cartilage width of both joint compartments. Knowledge of the condition of the articular cartilage in the non-weight-bearing compartment is important when considering a transfer of loading stresses by means of osteotomy. (orig.)

  15. Stress radiographs in the evaluation of degenerative femorotibial joint disease

    International Nuclear Information System (INIS)

    Tallroth, K.; Lindholm, T.S.

    1987-01-01

    Thirty-eight osteoarthrotic knees were examined to assess the widths of the femorotibial joint spaces. Radiographs were exposed with the patient lying, in a standing position, and with an adduction and abduction force. Forced compression of the osteoarthrotic joint compartment caused, on average, 18% greater narrowing than when loading it in the standing position. Compared to the joint space at rest, the non-weight-bearing compartment widened by 16% in the standing position and narrowed by 20% when stress was applied. Furthermore, the results showed an increase in laxity proportional to the degree of arthrosis. Stress radiographs significantly display the real cartilage width of both joint compartments. Knowledge of the condition of the articular cartilage in the non-weight-bearing compartment is important when considering a transfer of loading stresses by means of osteotomy. (orig.)

  16. Job stress and job satisfaction of physicians, radiographers, nurses and physicists working in radiotherapy: a multicenter analysis by the DEGRO Quality of Life Work Group

    International Nuclear Information System (INIS)

    Sehlen, Susanne; Wypior, Hans Joachim; Zehentmayr, Franz; Schulze, Wolfgang; Geinitz, Hans; Vordermark, Dirk; Schäfer, Christof; Herschbach, Peter; Bayerl, Anja; Pigorsch, Steffi; Rittweger, Jutta; Dormin, Claudia; Bölling, Tobias

    2009-01-01

    Ongoing changes in cancer care cause an increase in the complexity of cases which is characterized by modern treatment techniques and a higher demand for patient information about the underlying disease and therapeutic options. At the same time, the restructuring of health services and reduced funding have led to the downsizing of hospital care services. These trends strongly influence the workplace environment and are a potential source of stress and burnout among professionals working in radiotherapy. A postal survey was sent to members of the workgroup 'Quality of Life' which is part of DEGRO (German Society for Radiooncology). Thus far, 11 departments have answered the survey. 406 (76.1%) out of 534 cancer care workers (23% physicians, 35% radiographers, 31% nurses, 11% physicists) from 8 university hospitals and 3 general hospitals completed the FBAS form (Stress Questionnaire of Physicians and Nurses; 42 items, 7 scales), and a self-designed questionnaire regarding work situation and one question on global job satisfaction. Furthermore, the participants could make voluntary suggestions about how to improve their situation. Nurses and physicians showed the highest level of job stress (total score 2.2 and 2.1). The greatest source of job stress (physicians, nurses and radiographers) stemmed from structural conditions (e.g. underpayment, ringing of the telephone) a 'stress by compassion' (e.g. 'long suffering of patients', 'patients will be kept alive using all available resources against the conviction of staff'). In multivariate analyses professional group (p < 0.001), working night shifts (p = 0.001), age group (p = 0.012) and free time compensation (p = 0.024) gained significance for total FBAS score. Global job satisfaction was 4.1 on a 9-point scale (from 1 – very satisfied to 9 – not satisfied). Comparing the total stress scores of the hospitals and job groups we found significant differences in nurses (p = 0

  17. Job stress and job satisfaction of physicians, radiographers, nurses and physicists working in radiotherapy: a multicenter analysis by the DEGRO Quality of Life Work Group.

    Science.gov (United States)

    Sehlen, Susanne; Vordermark, Dirk; Schäfer, Christof; Herschbach, Peter; Bayerl, Anja; Pigorsch, Steffi; Rittweger, Jutta; Dormin, Claudia; Bölling, Tobias; Wypior, Hans Joachim; Zehentmayr, Franz; Schulze, Wolfgang; Geinitz, Hans

    2009-02-06

    Ongoing changes in cancer care cause an increase in the complexity of cases which is characterized by modern treatment techniques and a higher demand for patient information about the underlying disease and therapeutic options. At the same time, the restructuring of health services and reduced funding have led to the downsizing of hospital care services. These trends strongly influence the workplace environment and are a potential source of stress and burnout among professionals working in radiotherapy. A postal survey was sent to members of the workgroup "Quality of Life" which is part of DEGRO (German Society for Radiooncology). Thus far, 11 departments have answered the survey. 406 (76.1%) out of 534 cancer care workers (23% physicians, 35% radiographers, 31% nurses, 11% physicists) from 8 university hospitals and 3 general hospitals completed the FBAS form (Stress Questionnaire of Physicians and Nurses; 42 items, 7 scales), and a self-designed questionnaire regarding work situation and one question on global job satisfaction. Furthermore, the participants could make voluntary suggestions about how to improve their situation. Nurses and physicians showed the highest level of job stress (total score 2.2 and 2.1). The greatest source of job stress (physicians, nurses and radiographers) stemmed from structural conditions (e.g. underpayment, ringing of the telephone) a "stress by compassion" (e.g. "long suffering of patients", "patients will be kept alive using all available resources against the conviction of staff"). In multivariate analyses professional group (p working night shifts (p = 0.001), age group (p = 0.012) and free time compensation (p = 0.024) gained significance for total FBAS score. Global job satisfaction was 4.1 on a 9-point scale (from 1 - very satisfied to 9 - not satisfied). Comparing the total stress scores of the hospitals and job groups we found significant differences in nurses (p = 0.005) and physicists (p = 0.042) and a borderline

  18. Post traumatic stress disorder and the forensic radiographer

    International Nuclear Information System (INIS)

    Glaysher, E.; Vallis, J.; Reeves, P.

    2016-01-01

    The term post traumatic stress disorder (PTSD) is used to describe the psychological issues resulting from any traumatic event. An individual's ability to function is impaired by experiencing emotional responses to a traumatic event. Forensic radiographers need to be aware of the potential debilitating effects of this condition and those writing forensic protocols must take the condition into account and build in safeguards and welfare strategies. This narrative review looks at the origins of the term PTSD and highlights those who may be at increased risk of developing the condition including, in particular, forensic radiographers involved in mass fatality work. Signs, symptoms and possible treatments are also reviewed. - Highlights: • Presents a summary of PTSD for those working in forensic radiography. • Outlines signs & symptoms of PTSD. • Discusses treatment & prognosis of PTSD. • Suggests ways of managing factors which may predispose to PTSD.

  19. Effects of occupational stress and coping mechanisms adopted by radiographers in Ghana

    International Nuclear Information System (INIS)

    Ashong, G.G.N.A.; Rogers, H.; Botwe, B.O.; Anim-Sampong, S.

    2016-01-01

    Background: Studies have shown that population of radiography staff within various hospitals in Ghana decreased by 30% in the last decade due to several reasons. One of such reasons understood to be related to stress and job satisfaction which affect work output. Purpose: To investigate the effects of occupational stress and the coping mechanisms adopted by radiographers in Ghana. Method: A descriptive survey using a five-point Likert-scale questionnaire with pre-coded responses was administered via email to respondents. Purposive sampling method was used to select 190 radiographers who work in hospitals in Ghana. Descriptive statistics was mainly used to analyse the data using SPSS Version 20. Results: Of a total 190 questionnaires sent, 122 were completed and returned giving a 64.3% response rate. Majority 78 (64%) of respondents were males and the predominant area of work was conventional radiography. Most radiographers revealed they were stressed with 63% indicating high/very high levels of stress. The consequent effects of stress on radiographers were sick absence, depression and job dissatisfaction. Most of the radiographers used primary interventions to cope with stress. Conclusion: This study has demonstrated that most radiographers in Ghana are stressed. However, they cope well with problem-solving mechanisms. This suggests that the decrease in number of radiographers within various facilities in Ghana by 30% may not necessarily be caused by stress but other factors which need to be investigated. Nevertheless, occupational stress has an effect on radiographers' quality of working life and may directly impact on their behaviour during service delivery. - Highlights: • There is high level of occupational stress among Ghanaian Radiographers. • Some sources and causes of occupational stress among Ghanaian Radiographers were workload, poor pay and shortage of staff. • Job dissatisfaction, depression and sick absence were effects of occupational

  20. A radiographic analysis of implant component misfit.

    LENUS (Irish Health Repository)

    Sharkey, Seamus

    2011-07-01

    Radiographs are commonly used to assess the fit of implant components, but there is no clear agreement on the amount of misfit that can be detected by this method. This study investigated the effect of gap size and the relative angle at which a radiograph was taken on the detection of component misfit. Different types of implant connections (internal or external) and radiographic modalities (film or digital) were assessed.

  1. Measure by image analysis of industrial radiographs

    International Nuclear Information System (INIS)

    Brillault, B.

    1988-01-01

    A digital radiographic picture processing system for non destructive testing intends to provide the expert with computer tool, to precisely quantify radiographic images. The author describes the main problems, from the image formation to its characterization. She also insists on the necessity to define a precise process in order to automatize the system. Some examples illustrate the efficiency of digital processing for radiographic images [fr

  2. Methodological model of chronic stress associated with ligature-induced periodontitis in rats: a radiographic study

    Directory of Open Access Journals (Sweden)

    Alex Semenoff Segundo

    2010-12-01

    Full Text Available This study evaluated the time efficiency of stress associated with ligature-induced periodontitis in rats. Sixty adult Wistar rats, housed in temperature-controlled rooms and receiving water and food ad libitum, were randomly separated into stress (n = 30 or control groups (n = 30. All animals were anesthetized, and nylon ligatures were placed at the gingival margin level of the maxillary right second molars. After the induction of periodontitis, rats in the stress group were subjected to physical restraint for 12 hours daily. The animals were euthanized after 7, 15 and 30 days by anesthetic overdose (10 animals per group per period. The right hemimaxillae were stored in formalin solution for 48 hours. Parallel radiographic images of the hemimaxillae were taken and processed following standard procedures. Radiographic examination was performed by a blinded and previously calibrated investigator. Bone height level was measured, and data were submitted to analysis of variance and post hoc Bonferroni tests (p 0.05. Restraint stress modulates the short-term progression of periodontal disease in rats. Therefore, the 12-hour daily physical restraint stress model in rats applied for up to 15 days is suitable for the investigation of the combined effect of ligation and restraint stress on periodontal degradation.

  3. Significance of radiographic abnormalities in patients with tibial stress injuries: correlation with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kijowski, Richard; Choi, James; Smet, Arthur de; Mukharjee, Rajat

    2007-01-01

    The objective was to correlate radiographic findings with magnetic resonance imaging (MRI) findings in patients with suspected tibial stress injuries in order to determine the significance of radiographic signs of stress injury in these individuals. The study group consisted of 80 patients with suspected tibial stress injuries who underwent a radiographic and MR examination of the tibia. Nineteen patients had bilateral involvement. Thus, a total of 99 tibias were evaluated. All radiographs and MR examinations were retrospectively reviewed, 1 month apart, in consensus by two musculoskeletal radiologists. The radiographs were reviewed without knowledge of the site of the clinical symptoms. Fisher's exact tests were used to determine the association between a positive radiograph and the presence of various MRI signs of a high-grade stress injury. There was a strong association between the presence of periosteal reaction on radiographs at the site of the clinical symptoms and a Fredericson grade 4 stress injury on MRI. The presence of periosteal reaction on radiographs at the site of clinical symptoms is predictive of a high-grade stress injury by MRI criteria. (orig.)

  4. Computed image analysis of neutron radiographs

    International Nuclear Information System (INIS)

    Dinca, M.; Anghel, E.; Preda, M.; Pavelescu, M.

    2008-01-01

    Similar with X-radiography, using neutron like penetrating particle, there is in practice a nondestructive technique named neutron radiology. When the registration of information is done on a film with the help of a conversion foil (with high cross section for neutrons) that emits secondary radiation (β,γ) that creates a latent image, the technique is named neutron radiography. A radiographic industrial film that contains the image of the internal structure of an object, obtained by neutron radiography, must be subsequently analyzed to obtain qualitative and quantitative information about the structural integrity of that object. There is possible to do a computed analysis of a film using a facility with next main components: an illuminator for film, a CCD video camera and a computer (PC) with suitable software. The qualitative analysis intends to put in evidence possibly anomalies of the structure due to manufacturing processes or induced by working processes (for example, the irradiation activity in the case of the nuclear fuel). The quantitative determination is based on measurements of some image parameters: dimensions, optical densities. The illuminator has been built specially to perform this application but can be used for simple visual observation. The illuminated area is 9x40 cm. The frame of the system is a comparer of Abbe Carl Zeiss Jena type, which has been adapted to achieve this application. The video camera assures the capture of image that is stored and processed by computer. A special program SIMAG-NG has been developed at INR Pitesti that beside of the program SMTV II of the special acquisition module SM 5010 can analyze the images of a film. The major application of the system was the quantitative analysis of a film that contains the images of some nuclear fuel pins beside a dimensional standard. The system was used to measure the length of the pellets of the TRIGA nuclear fuel. (authors)

  5. Radiographic analysis of ameloblastoma: A retrospective study

    Directory of Open Access Journals (Sweden)

    Chandramani More

    2012-01-01

    Conclusion: Radiographs are an important aid for the diagnosis of oral lesions of various types, especially those that involve bone. It is important for the practicing clinicians to know the salient features of ameloblastoma which are peculiar to the local population.

  6. Radiographic analysis of pasteurized autologous bone graft

    International Nuclear Information System (INIS)

    Ahmed, Adel Refaat; Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi

    2003-01-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  7. Radiographic analysis of pasteurized autologous bone graft

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Adel Refaat [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan); Department of Orthopedic Surgery, Alexandria University, Alexandria (Egypt); Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan)

    2003-08-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  8. Image quality preferences among radiographers and radiologists. A conjoint analysis

    International Nuclear Information System (INIS)

    Ween, Borgny; Kristoffersen, Doris Tove; Hamilton, Glenys A.; Olsen, Dag Rune

    2005-01-01

    Purpose: The aim of this study was to investigate the image quality preferences among radiographers and radiologists. The radiographers' preferences are mainly related to technical parameters, whereas radiologists assess image quality based on diagnostic value. Methods: A conjoint analysis was undertaken to survey image quality preferences; the study included 37 respondents: 19 radiographers and 18 radiologists. Digital urograms were post-processed into 8 images with different properties of image quality for 3 different patients. The respondents were asked to rank the images according to their personally perceived subjective image quality. Results: Nearly half of the radiographers and radiologists were consistent in their ranking of the image characterised as 'very best image quality'. The analysis showed, moreover, that chosen filtration level and image intensity were responsible for 72% and 28% of the preferences, respectively. The corresponding figures for each of the two professions were 76% and 24% for the radiographers, and 68% and 32% for the radiologists. In addition, there were larger variations in image preferences among the radiologists, as compared to the radiographers. Conclusions: Radiographers revealed a more consistent preference than the radiologists with respect to image quality. There is a potential for image quality improvement by developing sets of image property criteria

  9. Radiographic analysis of temporomandibular joint arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    You, Dong Soo [Department of Oral Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1984-11-15

    The author analysed the bone changes, the positional relationships between condylar head and articular fossa, and the interrelationship between the bone changes and the abnormal position of condylar head, from 1,036 radiographs of 259 patients with temporomandibular joint arthrosis, which were obtained by the oblique-lateral transcranial projection and orthopantomograms. The results were as follows: 1. Among the radiographic bone changes of the temporomandibular joint arthrosis, deformity was 36..90% (217 cases), sclerosis 34.18% (201 cases), erosive change 25.58% (152 cases) and marginal proliferation 3.06% (18 cases) respectively. 2. In the positional changes between condylar head and articular fossa, the downward positioning of condylar head in centric occlusion was most frequent (36.90%), of which frequency was significantly higher than forward positioning (11.22%) and backward positioning (4.76%) in same condition. Also, radiographs showed that the enlargement of articular space showed higher frequency than its narrowing. In the opening position of mouth, the restrict ed movement of condylar head within articular fossa was most frequent (35.03%). The forward positioning and the downward positioning was 15.65% and 9.52% respectively. Also, radiographs revealed that the incomplete movement or no positional change of condylar head was most frequent. 3. In the interrelationship between bone changes and abnormal position of condylar head, deformity was 42.79% in the cases of downward positioning of condylar head in centric occlusion and 37.50% in those of normal positioning of condylar head in same condition. This revealed that deformity was most frequent bone change in above condylar positionings. However, erosive change was 34.62% in the cases of downward positioning of condylar head in centric occlusion and 33 .33% in those of forward positioning. In opening position of condylar head, and deformity in the cases of norma l positioning, forward positioning and

  10. Radiographic analysis of temporomandibular joint arthrosis

    International Nuclear Information System (INIS)

    You, Dong Soo

    1984-01-01

    The author analysed the bone changes, the positional relationships between condylar head and articular fossa, and the interrelationship between the bone changes and the abnormal position of condylar head, from 1,036 radiographs of 259 patients with temporomandibular joint arthrosis, which were obtained by the oblique-lateral transcranial projection and orthopantomograms. The results were as follows: 1. Among the radiographic bone changes of the temporomandibular joint arthrosis, deformity was 36..90% (217 cases), sclerosis 34.18% (201 cases), erosive change 25.58% (152 cases) and marginal proliferation 3.06% (18 cases) respectively. 2. In the positional changes between condylar head and articular fossa, the downward positioning of condylar head in centric occlusion was most frequent (36.90%), of which frequency was significantly higher than forward positioning (11.22%) and backward positioning (4.76%) in same condition. Also, radiographs showed that the enlargement of articular space showed higher frequency than its narrowing. In the opening position of mouth, the restrict ed movement of condylar head within articular fossa was most frequent (35.03%). The forward positioning and the downward positioning was 15.65% and 9.52% respectively. Also, radiographs revealed that the incomplete movement or no positional change of condylar head was most frequent. 3. In the interrelationship between bone changes and abnormal position of condylar head, deformity was 42.79% in the cases of downward positioning of condylar head in centric occlusion and 37.50% in those of normal positioning of condylar head in same condition. This revealed that deformity was most frequent bone change in above condylar positionings. However, erosive change was 34.62% in the cases of downward positioning of condylar head in centric occlusion and 33 .33% in those of forward positioning. In opening position of condylar head, and deformity in the cases of norma l positioning, forward positioning and

  11. Theoretical analysis of radiographic images by nonstationary Poisson processes

    International Nuclear Information System (INIS)

    Tanaka, Kazuo; Uchida, Suguru; Yamada, Isao.

    1980-01-01

    This paper deals with the noise analysis of radiographic images obtained in the usual fluorescent screen-film system. The theory of nonstationary Poisson processes is applied to the analysis of the radiographic images containing the object information. The ensemble averages, the autocorrelation functions, and the Wiener spectrum densities of the light-energy distribution at the fluorescent screen and of the film optical-density distribution are obtained. The detection characteristics of the system are evaluated theoretically. Numerical examples one-dimensional image are shown and the results are compared with those obtained under the assumption that the object image is related to the background noise by the additive process. (author)

  12. Observations of radiographer communication: An exploratory study using Transactional Analysis

    International Nuclear Information System (INIS)

    Booth, Lisa A.; Manning, David J.

    2006-01-01

    Purpose: Communication in medical imaging is a neglected area of research, despite the necessity for good communication if optimum diagnostic images are to be achieved. Methods: The present study has investigated the styles of communication used in medical imaging, using an approach known as Transactional Analysis. This approach has been demonstrated previously as having reliability and validity, using observations and supporting interviews with medical imaging staff, along with inter-rater observations of radiographer-patient interactions. Results: The results indicate that Transactional Analysis can be used effectively for identifying and naming interaction events in diagnostic radiography, with diagnostic radiographers using five styles of communication. Conclusion: Radiographers tend to use Parental styles of communicating; these styles are commonly associated with a practitioner-centred approach to dealing with patients which often result in non-adherence

  13. Digital radiographic techniques in the analysis of paintings

    International Nuclear Information System (INIS)

    James, A.E. Jr.; Gibbs, S.J.; James, A.E. III; Pickens, D.R.; Sloan, M.; Price, R.R.; Erickson, J.J.

    1985-01-01

    In this chapter the authors use the term digital radiography to mean any method of radiographic image production in which the silver halide-based film is replaced by an electronic sensor for production of an image. There are essentially three types of digital radiographic systems available at present, but others will be developed. These differ primarily in the method of image production and the rapidity with which images can be produced. The three methods discussed are digital fluoroscopy, scanned projection radiography, and the scanned point source radiography. Each has certain characteristics which, if properly utilized, will allow improved x-ray analysis of paintings

  14. Quantitative radiographic analysis of fiber reinforced polymer composites.

    Science.gov (United States)

    Baidya, K P; Ramakrishna, S; Rahman, M; Ritchie, A

    2001-01-01

    X-ray radiographic examination of the bone fracture healing process is a widely used method in the treatment and management of patients. Medical devices made of metallic alloys reportedly produce considerable artifacts that make the interpretation of radiographs difficult. Fiber reinforced polymer composite materials have been proposed to replace metallic alloys in certain medical devices because of their radiolucency, light weight, and tailorable mechanical properties. The primary objective of this paper is to provide a comparable radiographic analysis of different fiber reinforced polymer composites that are considered suitable for biomedical applications. Composite materials investigated consist of glass, aramid (Kevlar-29), and carbon reinforcement fibers, and epoxy and polyether-ether-ketone (PEEK) matrices. The total mass attenuation coefficient of each material was measured using clinical X-rays (50 kev). The carbon fiber reinforced composites were found to be more radiolucent than the glass and kevlar fiber reinforced composites.

  15. A study of trabecular bone strength and morphometric analysis of bone microstructure from digital radiographic image

    International Nuclear Information System (INIS)

    Han, Seung Yun; Lee, Sun Bok; Oh, Sung Ook; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul; Park, Tae Won; Kim, Jong Dae

    2003-01-01

    To evaluate the relationship between morphometric analysis of microstructure from digital radiographic image and trabecular bone strength. One hundred eleven bone specimens with 5 mm thickness were obtained from the mandibles of 5 pigs. Digital images of specimens were taken using a direct digital intraoral radiographic system. After selection of ROI(100 x 100 pixel) within the trabecular bone, mean gray level and standard deviation were obtained. Fractal dimension and the variants of morphometric analysis (trabecular area, periphery, length of skeletonized trabeculae, number of terminal point, number of branch point) were obtained from ROI. Punch sheer strength analysis was performed using Instron (model 4465, Instron Corp., USA). The loading force (loading speed 1mm/min) was applied to ROI of bone specimen by a 2 mm diameter punch. Stress-deformation curve was obtained from the punch sheer strength analysis and maximum stress, yield stress, Young's modulus were measured. Maximum stress had a negative linear correlation with mean gray level and fractal dimension significantly (p<0.05). Yield stress had a negative linear correlation with mean gray level, periphery, fractal dimension and the length of skeletonized trabeculae significantly (p<0.05). Young's modulus had a negative linear correlation with mean gray level and fractal dimension significantly (p<0.05). The strength of cancellous bone exhibited a significantly linear relationship between mean gray level, fractal dimension and morphometric analysis. The methods described above can be easily used to evaluate bone quality clinically.

  16. The prevalence and antecedents of occupational stress among radiographers in Zimbabwe: Interplay of economics and culture

    Directory of Open Access Journals (Sweden)

    Chingarande George R, Ndlovu Bekezela

    2013-04-01

    Full Text Available The purpose and objectives of this study were to find out the incidence of Occupational Stress amongst radiographers and also to find out the main stressors that they are exposed to. A cross sectional survey using both qualitative and quantitative methodologies and a questionnaire as a research tool was conducted. The questionnaire was given to all radiographers working in the general radiology department of the six departments/centres that participated in the study. The results revealed that there is a high incidence of occupational stress among medical radiographers working in general radiology. The results also showed that the most frequently encountered stressors in the general radiology department are pressure to complete tasks/overwork, inadequate salaries and inadequate holiday/vacation time. There were no significant differences in the incidences of occupational stress between male and female radiographers. However, there were differences in the perceptions of the two genders on the causes of stress. This was attributed to the cultural gender role expectations.

  17. The interest of radiographical investigations of bone diseases in the selection of stallions [orthopedic lesions, abnormal radiographic findings, multivariate analysis

    International Nuclear Information System (INIS)

    Valette, J.P.; Touzot, G.; Denoix, J.M.

    1997-01-01

    Breeding of sport horses requires products with qualities for performance traits. The objectives of this study were to investigate the relation between radiographical examination and descendant of sires. Foots, fetlocks of both thoracic and pelvic limbs, carpus, tarsus and stifles were examined radiographically in 225 3-year old horses descent from 25 stallions. Data were analysed by multivariate analysis. Results indicate that descendant of a stallion presents the same abnormal radiographic findings. It is concluded that bone diseases are of great importance in breeding sport horses and that these abnormalities could have a genetic component [fr

  18. Radiograph and passive data analysis using mixed variable optimization

    Science.gov (United States)

    Temple, Brian A.; Armstrong, Jerawan C.; Buescher, Kevin L.; Favorite, Jeffrey A.

    2015-06-02

    Disclosed herein are representative embodiments of methods, apparatus, and systems for performing radiography analysis. For example, certain embodiments perform radiographic analysis using mixed variable computation techniques. One exemplary system comprises a radiation source, a two-dimensional detector for detecting radiation transmitted through a object between the radiation source and detector, and a computer. In this embodiment, the computer is configured to input the radiographic image data from the two-dimensional detector and to determine one or more materials that form the object by using an iterative analysis technique that selects the one or more materials from hierarchically arranged solution spaces of discrete material possibilities and selects the layer interfaces from the optimization of the continuous interface data.

  19. Radiographic evaluation of coxofemoral joint laxity in dogs part II: Comparison of stress-radiographic positioning techniques in dogs with hip dysplasia

    International Nuclear Information System (INIS)

    Duangdaun Kaenkangploo; Phiwipha Kamonrat; Marissak Kalpravidh

    2002-01-01

    Two stress-radiographic positioning techniques for evaluation of coxofemoral joint laxity in dogs with hip dysplasia were compared with the standard technique. Forty, healthy, large breed dogs were divided into two groups of 20 dogs. Group 1 had normal hips. Group 2 were dogs with mild to moderated grade of hip dysplasia according to the Orthopedic Foundation for Animals (OFA) standard. Dogs were anesthetized and placed in dorsal recumbency before 3 radiographic techniques, standard hip-extended, 60 deg and 90 deg stress techniques, were taken. For the 60 deg stress technique, hind legs were extended in parallel to each other at 60 deg to the table top and femoral heads were manually pushed craniodorsally during exposure. For the 90 deg stress technique, femurs were positioned perpendicular to the table top, stifles were 90 deg flexed and adducted and femoral heads were manually pushed in a craniodorsal direction during exposure. Subluxation index (SI) and dorsolateral subluxation score (DLS score) of coxofemoral joints were assessed from radiographs. The SI of normal dogs from standard, 60 deg and 90 deg stress techniques were 0.15, 0.20 and 0.23 and of dysplastic dogs were 0.34, 0.40 and 0.41 respectively. The degress of subluxation assessed from the two stress technique radiographs were significantly greater (p0.05) than those shown on the standard technique radiographs in both groups of dogs. DLS scores of normal dogs from standard, 60 deg and 90 deg stress techniques were 65.1, 64.3 and 61.0 percent and of dysplastic dogs were 55.4, 53.6 and 47.6 percent respectively. Mean of DLS scores assessed from the 90 deg radiographs was significantly lower (p0.05) than those assessed from radiographs of other two teachniques in both groups of dogs. The findings suggested that the 90 deg stress technique is more efficient than the standard and 60 deg stress techniques for radiographic evaluation of coxofemoral joint laxity in dogs with mild hip dysplasia and early

  20. Retrospective panoramic radiographic analysis for idiopathic osteosclerosis in Indians

    Directory of Open Access Journals (Sweden)

    Srikanth H Srivathsa

    2016-01-01

    Full Text Available Introduction: Idiopathic osteosclerosis is an area of increased radiodensity observed on panoramic radiographs. The prevalence of this entity is not known, especially in Indians. Aims and Objectives: To determine the prevalence and epidemiological characteristics of idiopathic osteosclerosis. Materials and Methods: Six hundred and forty panoramic radiographs were retrospectively analyzed for the presence of idiopathic osteosclerosis by a single trained oral radiologist. Statistical Analysis: The data obtained were analyzed using Microsoft Excel (Version 2007 for Windows. Results: Idiopathic osteosclerosis was identified in 32 individuals with a prevalence of 5%. There were 21 female (65.7% and 11 male (34.3% participants. There were 31 single, unilateral (96.85% osteosclerotic lesions and 1 (3.15% bilateral lesion. Right side localization was noted in 19 participants (57.57% and left side localization in 14 participants (42.42%. Conclusion: This study illustrates the prevalence of idiopathic osteosclerosis in Indians. Further, it depicts the characteristics of idiopathic osteosclerotic lesions.

  1. Stress Analysis

    DEFF Research Database (Denmark)

    Burcharth, Hans F.

    The following types of forces contribute to the stresses in a Dolos in a pack exposed to waves: 1)Gravity forces Compaction forces (mainly due to settlements, gravity and flow forces) 2) Flow forces 3) Impact forces (impacts between moving concrete blocks)......The following types of forces contribute to the stresses in a Dolos in a pack exposed to waves: 1)Gravity forces Compaction forces (mainly due to settlements, gravity and flow forces) 2) Flow forces 3) Impact forces (impacts between moving concrete blocks)...

  2. Weightbearing vs Gravity Stress Radiographs for Stability Evaluation of Supination-External Rotation Fractures of the Ankle.

    Science.gov (United States)

    Seidel, Angela; Krause, Fabian; Weber, Martin

    2017-07-01

    Isolated lateral malleolar fractures may result from a supination-external rotation (SER) injury of the ankle. Stable fractures maintain tibiotalar congruence due to competent medial restraints and can be treated nonoperatively with excellent functional results and long-term prognosis. Stability might be assessed with either stress radiographs or weightbearing radiographs. A consecutive series of patients with closed SER fractures (presumed AO 44-B1) were prospectively enrolled from 2008 to 2015. Patients with clearly unstable fractures (medial clear space more than 7 mm) on the initial nonweightbearing radiograph were excluded and operated on. All other patients were examined with a gravity stress and a weightbearing anteroposterior radiograph. Borderline instability of the fracture was assumed when the medial clear space was 4 to 7 mm. Those were treated nonoperatively. Of 104 patients with isolated lateral malleolar fractures of the SER type, 14 patients were treated operatively because of clear instability (displacement) on the initial radiographs. Of the nonoperative patients, 44 patients demonstrated borderline instability on the gravity stress but stability on the weightbearing radiograph ("gravity borderline"); the remaining 46 were stable in both tests ("gravity stable"). At an average follow-up of 23 months, no significant differences were seen in the American Orthopaedic Foot & Ankle Society hindfoot score (92 points gravity-borderline group vs 93 points gravity-unstable group), the Foot Functional Index score (11 vs 10 points), the Short Form 36 (SF-36) physical component (86 vs 85 points), and SF-36 mental component (84 vs 81 points). Radiographically, all fractures had healed with anatomic congruity of the ankle. Weightbearing radiographs provided a reliable basis to decide about stability and nonoperative treatment in isolated lateral malleolar fractures of the SER type with excellent clinical and radiographic outcome at short-term follow-up. Gravity

  3. Radiographic analysis of partial or total vertebral body resection

    International Nuclear Information System (INIS)

    Whitten, C.G.; Hammer, G.H.; El-Khoury, G.Y.; Hugus, J.; Weinstein, J.N.

    1991-01-01

    Partial and total vertebrectomies are used in the treatment of primary and metastatic neoplasms of the spine. Serial radiographic studies are crucial in the follow-up of patients with vertebrectomies. This paper presents 33 cases and illustrates radiographic examples of both successful and complicated vertebrectomies, including radiographic signs of local tumor recurrence, loosening, migration or fracture of the hardware or methylmethacrylate, bone graft failure, and progressive spinal instability

  4. Stress fractures of the humerus, radius, and tibia in horses: clinical features and radiographic and/or scintigraphic appearance

    International Nuclear Information System (INIS)

    Mackey, V.S.; Trout, D.R.; Meagher, D.M.; Hornof, W.J.

    1987-01-01

    The medical records, radiographic and nuclear scintigraphic findings of 26 racing horses with 27 stress fracture episodes of the humerus, radius, or tibia were reviewed. The purposes of this study were to describe the radiographic and/or scintigraphic features of stress fractures of the humerus, radius, or tibia, and to evaluate the signalment and history of horses in which stress fracture occurred. Stress fractures of the three long bones examined were primarily seen in 2- and 3-year-old male Thoroughbred horses; commonly, the onset of lameness was immediately following training gallops or racing. There were 13 humeral stress fracture episodes in 12 horses. Ten were in the proximal caudolateral cortex, and three were in the distal craniomedial cortex. Radical stress fractures were seen in three horses, all in the midshaft radius. Tibial stress fractures were diagnosed in 11 horses. They were located in the proximal lateral tibia in six horses, the distal caudolateral tibia in three horses, and the midshaft tibia in three horses. Fifteen stress fractures were diagnosed with radiography alone, one was diagnosed with scintigraphy alone, nine were diagnosed with radiographs and scintigraphy, and, in two horses, radiographs were negative, but the scintigraphic findings were consistent with stress fracture

  5. Comparative analysis of human and bovine teeth: radiographic density

    Directory of Open Access Journals (Sweden)

    Jefferson Luis Oshiro Tanaka

    2008-12-01

    Full Text Available Since bovine teeth have been used as substitutes for human teeth in in vitro dental studies, the aim of this study was to compare the radiographic density of bovine teeth with that of human teeth to evaluate their usability for radiographic studies. Thirty bovine and twenty human teeth were cut transversally in 1 millimeter-thick slices. The slices were X-rayed using a digital radiographic system and an intraoral X-ray machine at 65 kVp and 7 mA. The exposure time (0.08 s and the target-sensor distance (40 cm were standardized for all the radiographs. The radiographic densities of the enamel, coronal dentin and radicular dentin of each slice were obtained separately using the "histogram" tool of Adobe Photoshop 7.0 software. The mean radiographic densities of the enamel, coronal dentin and radicular dentin were calculated by the arithmetic mean of the slices of each tooth. One-way ANOVA demonstrated statistically significant differences for the densities of bovine and human enamel (p 0.05. Based on the results, the authors concluded that: a the radiographic density of bovine enamel is significantly higher than that of human enamel; b the radiodensity of bovine coronal dentin is statistically lower than the radiodensity of human coronal dentin; bovine radicular dentin is also less radiodense than human radicular dentin, although this difference was not statistically significant; c bovine teeth should be used with care in radiographic in vitro studies.

  6. Quantitative analysis of bowel gas by plain abdominal radiograph combined with computer image processing

    International Nuclear Information System (INIS)

    Gao Yan; Peng Kewen; Zhang Houde; Shen Bixian; Xiao Hanxin; Cai Juan

    2003-01-01

    Objective: To establish a method for quantitative analysis of bowel gas by plain abdominal radiograph and computer graphics. Methods: Plain abdominal radiographs in supine position from 25 patients with irritable bowel syndrome (IBS) and 20 health controls were studied. A gastroenterologist and a radiologist independently conducted the following procedure on each radiograph. After the outline of bowel gas was traced by axe pen, the radiograph was digitized by a digital camera and transmitted to the computer with Histogram software. The total gas area was determined as the pixel value on images. The ratio of the bowel gas quantity to the pixel value in the region surrounded by a horizontal line tangential to the superior pubic symphysis margin, a horizontal line tangential to the tenth dorsal vertebra inferior margin, and the lateral line tangential to the right and left anteriosuperior iliac crest, was defined as the gas volume score (GVS). To examine the sequential reproducibility, a second plain abdominal radiograph was performed in 5 normal controls 1 week later, and the GVS were compared. Results: Bowel gas was easily identified on the plain abdominal radiograph. Both large and small intestine located in the selected region. Both observers could finish one radiographic measurement in less than 10 mins. The correlation coefficient between the two observers was 0.986. There was no statistical difference on GVS between the two sequential radiographs in 5 health controls. Conclusion: Quantification of bowel gas based on plain abdominal radiograph and computer is simple, rapid, and reliable

  7. Comparative radiographic analysis on the anatomical axis in knee osteoarthritis cases: inter and intraobserver evaluation.

    Science.gov (United States)

    Matos, Luiz Felipe; Giordano, Marcos; Cardoso, Gustavo Novaes; Farias, Rafael Baptista; E Albuquerque, Rodrigo Pires

    2015-01-01

    To make a comparative inter and intraobserver analysis on measurements of the anatomical axis between panoramic radiographs of the lower limbs in anteroposterior (AP) view with bipedal weight-bearing, on short film. An accuracy study comparing radiographic measurements on 47 knees of patients attending the knee surgery outpatient clinic due to osteoarthritis. The radiographic evaluation used was as standardized for the total knee arthroplasty program, including panoramic AP views of the lower limbs and short radiographs of the knees in AP and lateral views, all with bipedal weight-bearing. Following this, the anatomical axis of the lower limbs or the femorotibial angle was measured by five independent examiners on the panoramic and short AP radiographs; three of the examiners were considered to be more experienced and two, less experienced. All the measurements were made again by the same examiners after an interval of not less than 15 days. The statistical analysis was performed using the intraclass correlation coefficient, in order to evaluate the inter and intraobserver concordance of the anatomical axis measurements. From the statistical analysis, it was observed that there was strongly significant concordance between the anatomical axis measurements on the panoramic and short radiographs, for all the five examiners and for both measurements. Under the conditions studied, short radiographs were equivalent to panoramic radiographs for evaluating the anatomical axis of the lower limbs in patients with advanced osteoarthritis. The measurements used also showed high rates of inter and intraobserver concordance and reproducibility.

  8. Comparative radiographic analysis on the anatomical axis in knee osteoarthritis cases: inter and intraobserver evaluation

    Directory of Open Access Journals (Sweden)

    Luiz Felipe Matos

    2015-06-01

    Full Text Available OBJECTIVE: To make a comparative inter and intraobserver analysis on measurements of the anatomical axis between panoramic radiographs of the lower limbs in anteroposterior (AP view with bipedal weight-bearing, on short film.METHODS: An accuracy study comparing radiographic measurements on 47 knees of patients attending the knee surgery outpatient clinic due to osteoarthritis. The radiographic evaluation used was as standardized for the total knee arthroplasty program, including panoramic AP views of the lower limbs and short radiographs of the knees in AP and lateral views, all with bipedal weight-bearing. Following this, the anatomical axis of the lower limbs or the femorotibial angle was measured by five independent examiners on the panoramic and short AP radiographs; three of the examiners were considered to be more experienced and two, less experienced. All the measurements were made again by the same examiners after an interval of not less than 15 days. The statistical analysis was performed using the intraclass correlation coefficient, in order to evaluate the inter and intraobserver concordance of the anatomical axis measurements.RESULTS: From the statistical analysis, it was observed that there was strongly significant concordance between the anatomical axis measurements on the panoramic and short radiographs, for all the five examiners and for both measurements.CONCLUSIONS: Under the conditions studied, short radiographs were equivalent to panoramic radiographs for evaluating the anatomical axis of the lower limbs in patients with advanced osteoarthritis. The measurements used also showed high rates of inter and intraobserver concordance and reproducibility.

  9. Radiographic analysis of the course of Legionella pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Lo, C.D.; MacKeen, A.D.; Campbell, D.R.; Fraser, D.B.; Marrie, T.J. (Dalhousie Univ., Halifax, Nova Scotia (Canada))

    1983-06-01

    The radiographic findings in the acute phase of Legionella pneumonia are generally non-specific and have been previously documented. A retrospective assessment of 12 patients with this bacterial pneumonia revealed that resolution of the radiographic findings was prolonged in five. The predominant feature in such patients is the transient finding of interstitial consolidation following the air-space consolidation, not unlike that of Mycoplasma or viral pneumonia. Eventual return to normal was evident in three patients and residual parenchymal fibrosis was noted in two patients.

  10. Quantitative analysis of real-time radiographic systems

    International Nuclear Information System (INIS)

    Barker, M.D.; Condon, P.E.; Barry, R.C.; Betz, R.A.; Klynn, L.M.

    1988-01-01

    A method was developed which yields quantitative information on the spatial resolution, contrast sensitivity, image noise, and focal spot size from real time radiographic images. The method uses simple image quality indicators and computer programs which make it possible to readily obtain quantitative performance measurements of single or multiple radiographic systems. It was used for x-ray and optical images to determine which component of the system was not operating up to standard. Focal spot size was monitored by imaging a bar pattern. This paper constitutes the second progress report on the development of the camera and radiation image quality indicators

  11. Radiographic analysis of the course of Legionella pneumonia

    International Nuclear Information System (INIS)

    Lo, C.D.; MacKeen, A.D.; Campbell, D.R.; Fraser, D.B.; Marrie, T.J.

    1983-01-01

    The radiographic findings in the acute phase of Legionella pneumonia are generally non-specific and have been previously documented. A retrospective assessment of 12 patients with this bacterial pneumonia revealed that resolution of the radiographic findings was prolonged in five. The predominant feature in such patients is the transient finding of interstitial consolidation following the air-space consolidation, not unlike that of Mycoplasma or viral pneumonia. Eventual return to normal was evident in three patients and residual parenchymal fibrosis was noted in two patients

  12. Dynamic Stress Testing Is Unnecessary for Unimalleolar Supination-External Rotation Ankle Fractures with Minimal Fracture Displacement on Lateral Radiographs.

    Science.gov (United States)

    Nortunen, Simo; Leskelä, Hannu-Ville; Haapasalo, Heidi; Flinkkilä, Tapio; Ohtonen, Pasi; Pakarinen, Harri

    2017-03-15

    This study aimed to identify factors from standard radiographs that contributed to the stability of the ankle mortise in patients with isolated supination-external rotation fractures of the lateral malleolus (OTA/AO 44-B). Non-stress radiographs of the mortise and lateral views, without medial clear space widening or incongruity, were prospectively collected for 286 consecutive patients (mean age, 45 years [range, 16 to 85 years]), including 144 female patients (mean age, 50 years [range, 17 to 85 years]) and 142 male patients (mean age, 40 years [range, 16 to 84 years]) from 2 trauma centers. The radiographs were analyzed for fracture morphology by 2 orthopaedic surgeons, who were blinded to each other's measurements and to the results of external rotation stress radiographs (the reference for stability). Factors significantly associated with ankle mortise stability were tested in multiple logistic regression. Receiver operating characteristic analyses were performed for continuous variables to determine optimal thresholds. A sensitivity of >90% was used as the criterion for an optimal threshold. According to external rotation stress radiographs, 217 patients (75.9%) had a stable injury, defined as that with a medial clear space of ankle mortise were female sex (odds ratio [OR], 2.5 [95% confidence interval (CI), 1.4 to 4.6]), a posterior diastasis of fracture fragments (OR, 7.3 [95% CI, 2.1 to 26.3]). When the posterior diastasis was fracture fragments were present, the probability of a stable ankle mortise was 0.98 for 48 female patients (16.8%) and 0.94 for 37 male patients (12.9%). Patients with noncomminuted lateral malleolar fractures (85 patients [29.7%]) could be diagnosed with a stable ankle mortise without further stress testing, when the fracture line widths were <2 mm on lateral radiographs. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  13. Stress: a concept analysis.

    Science.gov (United States)

    Goodnite, Patricia M

    2014-01-01

    To analyze the concept of stress and provide an operational definition of stress. Literature review revealed that stress is a commonly used, but often ambiguous, term. Findings supported a definition of stress entailing an individual's perception of a stimulus as overwhelming, which in turn elicits a measurable response resulting in a transformed state. This analysis adopts a dynamic definition of stress that may serve to encourage communication, promote reflection, and enhance concept understanding. This definition may provide direction for future work, as well as enhance efforts to serve patients affected by stress. © 2013 Wiley Periodicals, Inc.

  14. Analysis of fuel-bundle radiographs using modeling

    International Nuclear Information System (INIS)

    Demuth, H.B.

    1975-07-01

    It was desired to estimate the thickness of gaps imaged on highly degraded radiographs. A powerful mathematical method for estimating gap widths was developed and applied. The problem, the techniques used to solve the problem, and results, conclusions, and suggestions for future work are presented. (U.S.)

  15. Radiographic analysis of body composition by computerized axial tomography

    International Nuclear Information System (INIS)

    Heymsfield, S.B.

    1986-01-01

    Radiographic methods of evaluating body composition have been applied for over five decades. A marked improvement in this approach occurred in the mid-nineteen-seventies with the introduction of computerized axial tomography. High image contrast, cross-sectional imaging and rapid computerized data processing make this technique a sophisticated clinically applicable tool. (author)

  16. Applications of uncertainty analysis to visual evaluation of density in radiographs

    International Nuclear Information System (INIS)

    Uchida, Suguru; Ohtsuka, Akiyoshi; Fujita, Hiroshi.

    1981-01-01

    Uncertainty analysis, developed as a method of absolute judgment in psychology, is applied to a method of radiographic image evaluation with perceptual fluctuations and to an examination of visual evaluation of density in radiographs. Subjects are composed of three groups of four neurosurgeons, four radiologic technologists and four nonprofessionals. By using a five-category rating scale, each observer is directed to classify 255 radiographs randomly presented without feedback. Characteristics of each observer and each group can be shown quantitatively by calculated information values. It is also described that bivariate uncertainty analysis or entropy method can be used to calculate the degree of agreement of evaluation. (author)

  17. Applications of uncertainty analysis to visual evaluation of density in radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, S [Gifu Univ. (Japan); Ohtsuka, A; Fujita, H

    1981-03-01

    Uncertainty analysis, developed as a method of absolute judgment in psychology, is applied to a method of radiographic image evaluation with perceptual fluctuations and to an examination of visual evaluation of density in radiographs. Subjects are composed of three groups of four neurosurgeons, four radiologic technologists and four nonprofessionals. By using a five-category rating scale, each observer is directed to classify 255 radiographs randomly presented without feedback. Characteristics of each observer and each group can be shown quantitatively by calculated information values. It is also described that bivariate uncertainty analysis or entropy method can be used to calculate the degree of agreement of evaluation.

  18. Radiographic test phantom for computed tomographic lung nodule analysis

    International Nuclear Information System (INIS)

    Zerhouni, E.A.

    1987-01-01

    This patent describes a method for evaluating a computed tomograph scan of a nodule in a lung of a human or non-human animal. The method comprises generating a computer tomograph of a transverse section of the animal containing lung and nodule tissue, and generating a second computer tomograph of a test phantom comprising a device which simulates the transverse section of the animal. The tissue simulating portions of the device are constructed of materials having radiographic densities substantially identical to those of the corresponding tissue in the simulated transverse section of the animal and have voids therein which simulate, in size and shape, the lung cavities in the transverse section and which contain a test reference nodule constructed of a material of predetermined radiographic density which simulates in size, shape and position within a lung cavity void of the test phantom the nodule in the transverse section of the animal and comparing the respective tomographs

  19. Computer assisted analysis of hand radiographs in infantile hypophosphatasia carriers

    International Nuclear Information System (INIS)

    Chodirker, B.N.; Greenberg, C.R.; Manitoba Univ., Winnipeg, MB; Roy, D.; Cheang, M.; Evans, J.A.; Manitoba Univ., Winnipeg, MB; Manitoba Univ., Winnipeg, MB; Reed, M.H.; Manitoba Univ., Winnipeg, MB

    1991-01-01

    Hand radiographs of 49 carriers of infantile hypophosphatasia and 67 non-carriers were evaluated using two Apple IIe Computer Programs and Apple Graphics Tablet. CAMPS was used to determine the bone lengths and calculate the metacarpophalangeal profiles. A newly developed program (ADAM) was used to determine bone density based on percent cortical area of the second metacarpal. Carriers of infantile hypophosphatasia had significantly less dense bones. (orig.)

  20. Operational parameters analysis of the radiographic technique through the modulation transfer function

    International Nuclear Information System (INIS)

    Motta, Mauricio Saldanha; Guimaraes, Ari Sauer

    1995-01-01

    The influence of the focal size and image magnification variations on the radiographic final image is studied. The analysis used the modulation transfer function for evaluating the ratio of the radiographic image amplitude and that of the inspected object. it was concluded that the increase of the focal size and of the magnifications are not good for the image quality. 3 refs., 4 figs., 1 tab

  1. Basic stress analysis

    CERN Document Server

    Iremonger, M J

    1982-01-01

    BASIC Stress Analysis aims to help students to become proficient at BASIC programming by actually using it in an important engineering subject. It also enables the student to use computing as a means of learning stress analysis because writing a program is analogous to teaching-it is necessary to understand the subject matter. The book begins by introducing the BASIC approach and the concept of stress analysis at first- and second-year undergraduate level. Subsequent chapters contain a summary of relevant theory, worked examples containing computer programs, and a set of problems. Topics c

  2. Design and evaluation of learning strategies for a group of radiographers in radiostereometric analysis (RSA).

    Science.gov (United States)

    Muharemovic, O; Troelsen, A; Thomsen, M G; Kallemose, T; Gosvig, K K

    2017-11-01

    The purpose of this study was to design and evaluate a radiostereometric analysis (RSA) program aimed at radiographers in order to increase their cognitive and practical skills, thereby increasing image quality and minimizing exposure repetition. Twenty radiographers were randomized into two identically sized study groups. Training consisted of a theoretical and practical workshop using a phantom. Tests were performed to compare the effect of training to nontraining, and the effect of time duration on the maintenance of RSA skills. The effect of training was measured by a written test and three defined parameters influencing image quality. Group A reduced significantly (p RSA X-ray training program where radiographers significantly improve their theoretical and practical skills in centering the CP closer to the CCF, NB and RP. A duration of up to two months after training does not influence the quality of participants' performance. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  3. Radiographic analysis of 1000 cast posts in Sergipe state, Brazil

    Directory of Open Access Journals (Sweden)

    Caroline Garcez MENDONÇA

    2017-09-01

    Full Text Available Abstract Introduction Endodontically treated teeth with extensive coronary destruction require posts and cores to enable prosthetic restoration. Despite the increasing use of prefabricated posts, cast metal posts and cores are still widely used. The quality of the latter is important for the longevity of restorative treatment, and failure can occur if the fundamental principles are not followed. Objective To radiographically evaluate the prosthetic principles of 1000 cast metal post-and-core restorations performed in single-rooted teeth and their coherence with the principles used for their confection. Material and method Digital periapical radiographs of 1000 endodontically treated, single-rooted teeth with cast metal posts and cores were selected from the collection of a radiology clinic (Centro de Imagem, Aracaju/SE, Brazil. The images were analyzed using a measurement software (ImageJ, USA in accordance with the fundamental prosthetic principles: length and diameter of the post, ratio between post and bone crest, contiguity of post to the root canal, gap between post and the remaining root canal filling, amount of remaining root canal filling, and absence of periapical lesion. The data were qualitatively analyzed, classified into ideal and not ideal, and submitted to the chi-square test (α=0.05. Result Only 6.7% of the cast metal posts analyzed were satisfactorily fabricated. Conclusion Many prosthetic criteria are neglected during the manufacturing of cast metal post and cores, resulting in inadequate work that may compromise the longevity of restorative treatments.

  4. Femoral neck buttressing: a radiographic and histologic analysis

    International Nuclear Information System (INIS)

    Dixon, T.; Benjamin, J.; Lund, P.; Graham, A.; Krupinski, E.

    2000-01-01

    Objective. To examine the incidence, radiographic and histologic findings of medial femoral neck buttressing in a consecutive group of patients undergoing total hip arthroplasty.Design. Biomechanical parameters were evaluated on standard anteroposterior pelvic radiographs of 113 patients prior to hip replacement surgery. Demographic information on all patients was reviewed and histologic evaluation was performed on specimens obtained at the time of surgery.Results. The incidence of medial femoral neck buttressing was found to be 50% in a consecutive series of patients undergoing total hip arthroplasty. The incidence was slightly higher in women (56% vs 41%). Patients with buttressing had increased neck-shaft angles and smaller femoral neck diameters than were seen in patients without buttressing. Histologic evaluation demonstrated that the buttress resulted from deposition bone by the periosteum on the femoral neck in the absence of any evidence of femoral neck fracture.Conclusion. It would appear that femoral neck buttressing occurs in response to increased joint reactive forces seen at the hip being transmitted through the femoral neck. The increased joint reactive force can be related to the increased neck shaft angle seen in patients with buttressing. (orig.)

  5. The video densitometric analysis of the radiographic density and contrast

    International Nuclear Information System (INIS)

    Yoo, Young Sun; Lee, Sang Rae

    1992-01-01

    Generally the patient's absorb dose and readability of radiograms are affected by the exposure time and kVp of which are related with the radiographic density and contrast. The investigator carried studies to know the adequate level of exposure time and kVp to obtain the better readability of radiograms. In these studies dried human mandible with each other by video densitometry among various combination sets of the exposure time, such as, 5, 6, 8, 12, 15, 19, 24, 30, 38, 48 and 60, and varing level of kVp, such as 60, 65, 70, 80 and 90 respectively. The obtained results were as follows: 1. As exposure time and kVp were increased, radiographic density of radiograms was increased. 2. The subject contrast was increased where aluminum step wedge was thin and reduced in the reversed condition. As the thin aluminum step wedge, subject contrast was increased at the condition of lower kilovoltage than that of higher kilovoltage. 3. In the case of non-contrast was increased in the lower kilovoltage with the longer exposure time and the higher kiovoltage with the shorter exposure time. 4. At the condition of short exposure time, bitter readability of each reading item was obtained with the increment of the kilovoltage but at the opposite condition increasing exposure time worsened readability of radiograms.Since X-ray machine in the current dental clinics is fixed between the range of 60-70 kVp and 10 mA, good radiograms can be obtained by varied exposure time. But according to the conclusion of these studies, better radiograms can be obtained by using filtered high kVp and then the absorb dose to patient and exposure time can be reduced.

  6. Semi-automated digital image analysis of patellofemoral joint space width from lateral knee radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Grochowski, S.J. [Mayo Clinic, Department of Orthopedic Surgery, Rochester (United States); Amrami, K.K. [Mayo Clinic, Department of Radiology, Rochester (United States); Kaufman, K. [Mayo Clinic, Department of Orthopedic Surgery, Rochester (United States); Mayo Clinic/Foundation, Biomechanics Laboratory, Department of Orthopedic Surgery, Charlton North L-110L, Rochester (United States)

    2005-10-01

    To design a semi-automated program to measure minimum patellofemoral joint space width (JSW) using standing lateral view radiographs. Lateral patellofemoral knee radiographs were obtained from 35 asymptomatic subjects. The radiographs were analyzed to report both the repeatability of the image analysis program and the reproducibility of JSW measurements within a 2 week period. The results were also compared with manual measurements done by an experienced musculoskeletal radiologist. The image analysis program was shown to have an excellent coefficient of repeatability of 0.18 and 0.23 mm for intra- and inter-observer measurements respectively. The manual method measured a greater minimum JSW than the automated method. Reproducibility between days was comparable to other published results, but was less satisfactory for both manual and semi-automated measurements. The image analysis program had an inter-day coefficient of repeatability of 1.24 mm, which was lower than 1.66 mm for the manual method. A repeatable semi-automated method for measurement of the patellofemoral JSW from radiographs has been developed. The method is more accurate than manual measurements. However, the between-day reproducibility is higher than the intra-day reproducibility. Further investigation of the protocol for obtaining sequential lateral knee radiographs is needed in order to reduce the between-day variability. (orig.)

  7. A pilot study to determine the effect of radiographer training on radiostereometric analysis imaging technique

    DEFF Research Database (Denmark)

    Muharemovic, O; Troelsen, A; Thomsen, M G

    2018-01-01

    INTRODUCTION: Producing x-ray images for radiostereometric analysis (RSA) is a demanding technique. Suboptimal examinations result in a high percentage of exposure repetition. The aim of this pilot study was to use an experiential training approach to sharpen the skills of radiographers in acquir......INTRODUCTION: Producing x-ray images for radiostereometric analysis (RSA) is a demanding technique. Suboptimal examinations result in a high percentage of exposure repetition. The aim of this pilot study was to use an experiential training approach to sharpen the skills of radiographers...

  8. Stress Analysis of Composites.

    Science.gov (United States)

    1981-01-01

    8217, Finite Elements in Nonlinear Mechanics, 1., 109-130, Tapir Publishers, Norway (1978). 9. A.J. Barnard and P.W. Sharman, ’Elastic-Plastic Analysis Using...Hybrid Stress Finite Elements,’ Finite Elements in Nonlinear Mechanics, 1, 131-148, Tapir Publishers Norway, (1978). ’.........Pian, ’Variational

  9. Design and evaluation of learning strategies for a group of radiographers in radiostereometric analysis (RSA)

    DEFF Research Database (Denmark)

    Muharemovic, O; Troelsen, A; Thomsen, M G

    2017-01-01

    INTRODUCTION: The purpose of this study was to design and evaluate a radiostereometric analysis (RSA) program aimed at radiographers in order to increase their cognitive and practical skills, thereby increasing image quality and minimizing exposure repetition. METHODS AND MATERIALS: Twenty...... radiographers were randomized into two identically sized study groups. Training consisted of a theoretical and practical workshop using a phantom. Tests were performed to compare the effect of training to nontraining, and the effect of time duration on the maintenance of RSA skills. The effect of training...... after training group B had experienced overall significant improvement on a par with group A. CONCLUSION: It is realistic to implement an RSA X-ray training program where radiographers significantly improve their theoretical and practical skills in centering the CP closer to the CCF, NB and RP...

  10. New view on the initial development site and radiographic classification system of osteoarthritis of the knee based on radiographic analysis.

    Science.gov (United States)

    Moon, Ki-Ho

    2012-12-01

    Radiographic pathology of severe osteoarthritis of the knee (OAK) such as severe osteophyte at tibial spine (TS), compartment narrowing, marginal osteophyte, and subchondral sclerosis is well known. Kellgren-Lawrence grading system, which is widely used to diagnose OAK, describes narrowing-marginal osteophyte in 4-grades but uses osteophyte at TS only as evidence of OAK without detailed-grading. However, kinematically the knee employs medial TS as an axis while medial and lateral compartments carry the load, suggesting that early OAK would occur sooner at TS than at compartment. Then, Kellgren-Lawrence system may be inadequate to diagnose early-stage OAK manifested as a subtle osteophyte at TS without narrowing-marginal osteophyte. This undiagnosed-OAK will deteriorate becoming a contributing factor in an increasing incidence of OAK. This study developed a radiographic OAK-marker based on both osteophyte at TS and compartment narrowing-marginal osteophyte and graded as normal, mild, moderate, and severe. With this marker, both knee radiographs of 1,728 patients with knee pain were analyzed. Among 611 early-stage mild OAK, 562 or 92% started at TS and 49 or 8% at compartment. It suggests the initial development site of OAK, helping develop new site-specific radiographic classification system of OAK accurately to diagnose all severity of OAK at early, intermediate, or late-stage. It showed that Kellgren-Lawrence system missed 92.0% of early-stage mild OAK from diagnosis. A subtle osteophyte at TS is the earliest radiographic sign of OAK. A new radiographic classification system of OAK was suggested for accurate diagnosis of all OAK in severity and at stage.

  11. Computer-assisted analysis of cervical vertebral bone age using cephalometric radiographs in Brazilian subjects.

    Science.gov (United States)

    Caldas, Maria de Paula; Ambrosano, Gláucia Maria Bovi; Haiter Neto, Francisco

    2010-01-01

    The aims of this study were to develop a computerized program for objectively evaluating skeletal maturation on cephalometric radiographs, and to apply the new method to Brazilian subjects. The samples were taken from the patient files of Oral Radiological Clinics from the North, Northeast, Midwest and South regions of the country. A total of 717 subjects aged 7.0 to 15.9 years who had lateral cephalometric radiographs and hand-wrist radiographs were selected. A cervical vertebral computerized analysis was created in the Radiocef Studio 2 computer software for digital cephalometric analysis, and cervical vertebral bone age was calculated using the formulas developed by Caldas et al.17 (2007). Hand-wrist bone age was evaluated by the TW3 method. Analysis of variance (ANOVA) and the Tukey test were used to compare cervical vertebral bone age, hand-wrist bone age and chronological age (P cervical vertebral bone age and chronological age in all regions studied. When analyzing bone age, it was possible to observe a statistically significant difference between cervical vertebral bone age and hand-wrist bone age for female and male subjects in the North and Northeast regions, as well as for male subjects in the Midwest region. No significant difference was observed between bone age and chronological age in all regions except for male subjects in the North and female subjects in the Northeast. Using cervical vertebral bone age, it might be possible to evaluate skeletal maturation in an objective manner using cephalometric radiographs.

  12. Thin-plate spline (TPS) graphical analysis of the mandible on cephalometric radiographs.

    Science.gov (United States)

    Chang, H P; Liu, P H; Chang, H F; Chang, C H

    2002-03-01

    We describe two cases of Class III malocclusion with and without orthodontic treatment. A thin-plate spline (TPS) analysis of lateral cephalometric radiographs was used to visualize transformations of the mandible. The actual sites of mandibular skeletal change are not detectable with conventional cephalometric analysis. These case analyses indicate that specific patterns of mandibular transformation are associated with Class III malocclusion with or without orthopaedic therapy, and visualization of these deformations is feasible using TPS graphical analysis.

  13. Quantitative analysis of alveolar bone change following implant placement using intraoral radiographic subtraction

    International Nuclear Information System (INIS)

    Kimura, Hiroyuki; Kanda, Shigenobu; Tanaka, Takemasa

    2002-01-01

    The purpose of this study was to develop a procedure for quantitative analysis using intraoral radiographs of alveolar bone after placement of dental implants and to consider the validity of the method. We evaluated the ten patients (2 males and 8 females, average age: 48.4 years-old), who were treated with dental implant operation in the site of mandibular molar region, since October of 1999 until September of 2000 in Kimura Dental Clinic (Kumamoto, Japan). We evaluated the intraoral radiographs taken pre- and post- operatively and at follow-up examination. To detect alveolar bone change on radiograph, we adopted the digital subtraction method. Although the radiographs were taken under an ordinary technique with cone indicator, we did not apply the standardized technique with fixing material customized for each patient. Therefore, we used geometric correction and density compensation before subtraction. We assessed the basic statistical values (mean, variance, kurtosis and skewness) of the region of interest (ROI) of the subtracted images. Also, we noted PPD (probing pocket depth) and BOP (bleeding on probing) at each site as indicators of clinical findings and all implanted sites were classified according to the PPD or BOP, i.e. PPD increased group ''PPD (+)'' and PPD stable group ''PPD (-)'', likewise BOP positive group ''BOP (+)'' and negative group ''BOP (-)''. We considered the statistical values of ROI in each group and compared these findings. Mean and variance values of PPD (+) were higher than those of PPD (-) and there was a significant difference in mean value (p=0.031). Similarly, mean and variance values of BOP (+) were statistically higher than those of BOP (-) (p=0.041 and p=0.0087, respectively). Concerning kurtosis and skewness, there was no difference between PPD (+) and PPD (-), or between BOP (+) and BOP (-). Using our method, the radiographs taken for follow-up examination could be assessed quantitatively. It is suggested that geometric

  14. Can Australian radiographers assess screening mammograms accurately? Biennial follow-up from a four year prospective study and lesion analysis

    International Nuclear Information System (INIS)

    Moran, S.; Warren-Forward, H.

    2016-01-01

    Introduction: Globally, the role of the radiographer is changing; some countries have developed advanced roles with specific scopes of practice. Other countries, like Australia, are in the process of this change. This paper demonstrates the abilities of Australian radiographers in mammogram screen reading, highlighting some of their specific difficulties with different lesion types. Method: Six experienced radiographers participated in a prospective study, screen reading 2000 mammograms each between 2010 and 2011. This paper looks at the results of those same women at biennial re-screen. Analysis of the results included validation of normal results by negative follow-up screens and new cancers at biennial review; there is also analysis on the types of lesions detected and missed. Results: After biennial review, three cancers in 2013/2014 had been marked as abnormal by one radiographer two years prior, which increased her sensitivity from 64% to 85%. Sensitivity for the radiologists decreased from the assumed 100% to 95%. Radiographers appeared to be skilled in detection of calcifications and architectural distortions but had difficulty with non-specific densities. Conclusion: This study demonstrates the potential for Australian radiographers to enhance the accuracy of screen reading programs. - Highlights: • Radiographers have the potential to increase breast cancer detection rates. • Radiographers appear to be skilled at detecting calcifications. • Lesions commonly overlooked by radiographers could be targeted for training.

  15. Reliability and accuracy analysis of a new semiautomatic radiographic measurement software in adult scoliosis.

    Science.gov (United States)

    Aubin, Carl-Eric; Bellefleur, Christian; Joncas, Julie; de Lanauze, Dominic; Kadoury, Samuel; Blanke, Kathy; Parent, Stefan; Labelle, Hubert

    2011-05-20

    Radiographic software measurement analysis in adult scoliosis. To assess the accuracy as well as the intra- and interobserver reliability of measuring different indices on preoperative adult scoliosis radiographs using a novel measurement software that includes a calibration procedure and semiautomatic features to facilitate the measurement process. Scoliosis requires a careful radiographic evaluation to assess the deformity. Manual and computer radiographic process measures have been studied extensively to determine the reliability and reproducibility in adolescent idiopathic scoliosis. Most studies rely on comparing given measurements, which are repeated by the same user or by an expert user. A given measure with a small intra- or interobserver error might be deemed as good repeatability, but all measurements might not be truly accurate because the ground-truth value is often unknown. Thorough accuracy assessment of radiographic measures is necessary to assess scoliotic deformities, compare these measures at different stages or to permit valid multicenter studies. Thirty-four sets of adult scoliosis digital radiographs were measured two times by three independent observers using a novel radiographic measurement software that includes semiautomatic features to facilitate the measurement process. Twenty different measures taken from the Spinal Deformity Study Group radiographic measurement manual were performed on the coronal and sagittal images. Intra- and intermeasurer reliability for each measure was assessed. The accuracy of the measurement software was also assessed using a physical spine model in six different scoliotic configurations as a true reference. The majority of the measures demonstrated good to excellent intra- and intermeasurer reliability, except for sacral obliquity. The standard variation of all the measures was very small: ≤ 4.2° for Cobb angles, ≤ 4.2° for the kyphosis, ≤ 5.7° for the lordosis, ≤ 3.9° for the pelvic angles, and

  16. Radiographic analysis of the development of the pelvic limb of captive-reared cranes (Grus spp.)

    International Nuclear Information System (INIS)

    Curro, T.G.; Langenberg, J.A.; Deakin, L.

    1996-01-01

    For captive-reared cranes, pelvic limb abnormalities in chicks have been identified as significant morbidity/mortality factors. An important component of the diagnosis of limb abnormalities is the understanding of the normal limb. This study was undertaken to describe the normal, radiographic development of the femur, tibiotarsus, tarsometatarsus, and fibula of the whooping crane (Grus americana), Florida sandhill crane (Grus canadensis pratensis), and Siberian crane (Grus leucogeranus). Crane chicks were anesthetized and their pelvic limb bone development evaluated radiographically on a weekly to bimonthly basis from one to fourteen weeks of age. Body weight, bone length, diaphyseal width, and physeal development and closure were evaluated. Based on the radiographic analysis, the gross development of the long bones of the pelvic limb of whooping, Florida sandhill, and Siberian cranes was found to be similar among the three species, and not dissimilar from other avian species which have been studied. Repeated handling, anesthesia, and radiographic exposure did not produce any behavioral, developmental, or physical abnormalities in the studied cranes when compared to cranes of the same species raised using the same methods. This is the first work to describe pelvic limb bone development in these species

  17. New View on the Initial Development Site and Radiographic Classification System of Osteoarthritis of the Knee Based on Radiographic Analysis

    OpenAIRE

    Moon, Ki-Ho

    2012-01-01

    Introduction: Radiographic pathology of severe osteoarthritis of the knee (OAK) such as severe osteophyte at tibial spine (TS), compartment narrowing, marginal osteophyte, and subchondral sclerosis is well known. Kellgren-Lawrence grading system, which is widely used to diagnose OAK, describes narrowing-marginal osteophyte in 4-grades but uses osteophyte at TS only as evidence of OAK without detailed-grading. However, kinematically the knee employs medial TS as an axis while medial and latera...

  18. Foreign object detection and removal to improve automated analysis of chest radiographs

    International Nuclear Information System (INIS)

    Hogeweg, Laurens; Sánchez, Clara I.; Melendez, Jaime; Maduskar, Pragnya; Ginneken, Bram van; Story, Alistair; Hayward, Andrew

    2013-01-01

    Purpose: Chest radiographs commonly contain projections of foreign objects, such as buttons, brassier clips, jewellery, or pacemakers and wires. The presence of these structures can substantially affect the output of computer analysis of these images. An automated method is presented to detect, segment, and remove foreign objects from chest radiographs.Methods: Detection is performed using supervised pixel classification with a kNN classifier, resulting in a probability estimate per pixel to belong to a projected foreign object. Segmentation is performed by grouping and post-processing pixels with a probability above a certain threshold. Next, the objects are replaced by texture inpainting.Results: The method is evaluated in experiments on 257 chest radiographs. The detection at pixel level is evaluated with receiver operating characteristic analysis on pixels within the unobscured lung fields and an A z value of 0.949 is achieved. Free response operator characteristic analysis is performed at the object level, and 95.6% of objects are detected with on average 0.25 false positive detections per image. To investigate the effect of removing the detected objects through inpainting, a texture analysis system for tuberculosis detection is applied to images with and without pathology and with and without foreign object removal. Unprocessed, the texture analysis abnormality score of normal images with foreign objects is comparable to those with pathology. After removing foreign objects, the texture score of normal images with and without foreign objects is similar, while abnormal images, whether they contain foreign objects or not, achieve on average higher scores.Conclusions: The authors conclude that removal of foreign objects from chest radiographs is feasible and beneficial for automated image analysis

  19. Biometric Analysis – A Reliable Indicator for Diagnosing Taurodontism using Panoramic Radiographs

    Science.gov (United States)

    Hegde, Veda; Anegundi, Rajesh Trayambhak; Pravinchandra, K.R.

    2013-01-01

    Background: Taurodontism is a clinical entity with a morpho–anatomical change in the shape of the tooth, which was thought to be absent in modern man. Taurodontism is mostly observed as an isolated trait or a component of a syndrome. Various techniques have been devised to diagnose taurodontism. Aim: The aim of this study was to analyze whether a biometric analysis was useful in diagnosing taurodontism, in radiographs which appeared to be normal on cursory observations. Setting and Design: This study was carried out in our institution by using radiographs which were taken for routine procedures. Material and Methods: In this retrospective study, panoramic radiographs were obtained from dental records of children who were aged between 9–14 years, who did not have any abnormality on cursory observations. Biometric analyses were carried out on permanent mandibular first molar(s) by using a novel biometric method. The values were tabulated and analysed. Statistics: Fischer exact probability test, Chi square test and Chi-square test with Yates correction were used for statistical analysis of the data. Results: Cursory observation did not yield us any case of taurodontism. In contrast, the biometric analysis yielded us a statistically significant number of cases of taurodontism. However, there was no statistically significant difference in the number of cases with taurodontism, which was obtained between the genders and the age group which was considered. Conclusion: Thus, taurodontism was diagnosed on a biometric analysis, which was otherwise missed on a cursory observation. It is therefore necessary from the clinical point of view, to diagnose even the mildest form of taurodontism by using metric analysis rather than just relying on a visual radiographic assessment, as its occurrence has many clinical implications and a diagnostic importance. PMID:24086912

  20. Biometric Analysis - A Reliable Indicator for Diagnosing Taurodontism using Panoramic Radiographs.

    Science.gov (United States)

    Hegde, Veda; Anegundi, Rajesh Trayambhak; Pravinchandra, K R

    2013-08-01

    Taurodontism is a clinical entity with a morpho-anatomical change in the shape of the tooth, which was thought to be absent in modern man. Taurodontism is mostly observed as an isolated trait or a component of a syndrome. Various techniques have been devised to diagnose taurodontism. The aim of this study was to analyze whether a biometric analysis was useful in diagnosing taurodontism, in radiographs which appeared to be normal on cursory observations. This study was carried out in our institution by using radiographs which were taken for routine procedures. In this retrospective study, panoramic radiographs were obtained from dental records of children who were aged between 9-14 years, who did not have any abnormality on cursory observations. Biometric analyses were carried out on permanent mandibular first molar(s) by using a novel biometric method. The values were tabulated and analysed. Fischer exact probability test, Chi square test and Chi-square test with Yates correction were used for statistical analysis of the data. Cursory observation did not yield us any case of taurodontism. In contrast, the biometric analysis yielded us a statistically significant number of cases of taurodontism. However, there was no statistically significant difference in the number of cases with taurodontism, which was obtained between the genders and the age group which was considered. Thus, taurodontism was diagnosed on a biometric analysis, which was otherwise missed on a cursory observation. It is therefore necessary from the clinical point of view, to diagnose even the mildest form of taurodontism by using metric analysis rather than just relying on a visual radiographic assessment, as its occurrence has many clinical implications and a diagnostic importance.

  1. Radiographic analysis in works of art - its utilization in the restoration, conservation and authentification

    International Nuclear Information System (INIS)

    Esteves, C.A.; Coelho, J.C.; Pereira, A.A.; Mendes, M.; Cunha, A.P.; Fernandes, L.E.A.P.V.; Menezes Freitas, A. de; Batista, A.C.N.

    1990-01-01

    The radiographic methods are important in the scientific inquiry of the art and archaelogic works throughout the world. In Brazil, this study has been realized at a few biological research groups and no more development can be recognized. By the radiographic analysis of six oils on canvas assigned to Ataide (Manuel da Costa Ataide), an impressionist painter of the 18th century, the authors try to determine his main technical pattern (distribution of heavy metal pigments, application of thick layers of pigment, etc.). The basic compositional elements were evaluated along with chemical tests and analysis by ultraviolet and infrared radiations, representing a historic document about Ataide's style. Each technique will be related to the purpose of the inquiry, affording the authors the opportunity to offer comments upon restoration, conservation and authentification of paintings. (author) [pt

  2. Computer-assisted analysis of cervical vertebral bone age using cephalometric radiographs in Brazilian subjects

    Directory of Open Access Journals (Sweden)

    Maria de Paula Caldas

    2010-03-01

    Full Text Available The aims of this study were to develop a computerized program for objectively evaluating skeletal maturation on cephalometric radiographs, and to apply the new method to Brazilian subjects. The samples were taken from the patient files of Oral Radiological Clinics from the North, Northeast, Midwest and South regions of the country. A total of 717 subjects aged 7.0 to 15.9 years who had lateral cephalometric radiographs and hand-wrist radiographs were selected. A cervical vertebral computerized analysis was created in the Radiocef Studio 2 computer software for digital cephalometric analysis, and cervical vertebral bone age was calculated using the formulas developed by Caldas et al.17 (2007. Hand-wrist bone age was evaluated by the TW3 method. Analysis of variance (ANOVA and the Tukey test were used to compare cervical vertebral bone age, hand-wrist bone age and chronological age (P < 0.05. No significant difference was found between cervical vertebral bone age and chronological age in all regions studied. When analyzing bone age, it was possible to observe a statistically significant difference between cervical vertebral bone age and hand-wrist bone age for female and male subjects in the North and Northeast regions, as well as for male subjects in the Midwest region. No significant difference was observed between bone age and chronological age in all regions except for male subjects in the North and female subjects in the Northeast. Using cervical vertebral bone age, it might be possible to evaluate skeletal maturation in an objective manner using cephalometric radiographs.

  3. Development and testing of texture discriminators for the analysis of trabecular bone in proximal femur radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Huber, M. B.; Carballido-Gamio, J.; Fritscher, K.; Schubert, R.; Haenni, M.; Hengg, C.; Majumdar, S.; Link, T. M. [Department of Radiology and Biomedical Imaging, University of California, 400 Parnassus Avenue, San Francisco, California 94143 (United States); University of Health Sciences, Medical Informatics and Technology, 6060 Hall (Austria); AO Development Institute, 7270 Davos Platz (Switzerland); Medical University Innsbruck, 6020 Innsbruck (Austria); Department of Radiology and Biomedical Imaging, University of California, 400 Parnassus Avenue, San Francisco, California 94143 (United States)

    2009-11-15

    Purpose: Texture analysis of femur radiographs may serve as a potential low cost technique to predict osteoporotic fracture risk and has received considerable attention in the past years. A further application of this technique may be the measurement of the quality of specific bone compartments to provide useful information for treatment of bone fractures. Two challenges of texture analysis are the selection of the best suitable texture measure and reproducible placement of regions of interest (ROIs). The goal of this in vitro study was to automatically place ROIs in radiographs of proximal femur specimens and to calculate correlations between various different texture analysis methods and the femurs' anchorage strength. Methods: Radiographs were obtained from 14 femoral specimens and bone mineral density (BMD) was measured in the femoral neck. Biomechanical testing was performed to assess the anchorage strength in terms of failure load, breakaway torque, and number of cycles. Images were segmented using a framework that is based on the usage of level sets and statistical in-shape models. Five ROIs were automatically placed in the head, upper and lower neck, trochanteric, and shaft compartment in an atlas subject. All other subjects were registered rigidly, affinely, and nonlinearly, and the resulting transformation was used to map the five ROIs onto the individual femora. Results: In each ROI, texture features were extracted using gray level co-occurence matrices (GLCM), third-order GLCM, morphological gradients (MGs), Minkowski dimensions (MDs), Minkowski functionals (MFs), Gaussian Markov random fields, and scaling index method (SIM). Coefficients of determination for each texture feature with parameters of anchorage strength were computed. In a stepwise multiregression analysis, the most predictive parameters were identified in different models. Texture features were highly correlated with anchorage strength estimated by the failure load of up to R{sup 2

  4. Development and testing of texture discriminators for the analysis of trabecular bone in proximal femur radiographs

    International Nuclear Information System (INIS)

    Huber, M. B.; Carballido-Gamio, J.; Fritscher, K.; Schubert, R.; Haenni, M.; Hengg, C.; Majumdar, S.; Link, T. M.

    2009-01-01

    Purpose: Texture analysis of femur radiographs may serve as a potential low cost technique to predict osteoporotic fracture risk and has received considerable attention in the past years. A further application of this technique may be the measurement of the quality of specific bone compartments to provide useful information for treatment of bone fractures. Two challenges of texture analysis are the selection of the best suitable texture measure and reproducible placement of regions of interest (ROIs). The goal of this in vitro study was to automatically place ROIs in radiographs of proximal femur specimens and to calculate correlations between various different texture analysis methods and the femurs' anchorage strength. Methods: Radiographs were obtained from 14 femoral specimens and bone mineral density (BMD) was measured in the femoral neck. Biomechanical testing was performed to assess the anchorage strength in terms of failure load, breakaway torque, and number of cycles. Images were segmented using a framework that is based on the usage of level sets and statistical in-shape models. Five ROIs were automatically placed in the head, upper and lower neck, trochanteric, and shaft compartment in an atlas subject. All other subjects were registered rigidly, affinely, and nonlinearly, and the resulting transformation was used to map the five ROIs onto the individual femora. Results: In each ROI, texture features were extracted using gray level co-occurence matrices (GLCM), third-order GLCM, morphological gradients (MGs), Minkowski dimensions (MDs), Minkowski functionals (MFs), Gaussian Markov random fields, and scaling index method (SIM). Coefficients of determination for each texture feature with parameters of anchorage strength were computed. In a stepwise multiregression analysis, the most predictive parameters were identified in different models. Texture features were highly correlated with anchorage strength estimated by the failure load of up to R 2 =0.61 (MF

  5. Analysis of radiographic bone parameters throughout the surgical lengthening and deformity correction of extremities.

    Science.gov (United States)

    Atanasov, Nenad; Poposka, Anastasika; Samardziski, Milan; Kamnar, Viktor

    2014-01-01

    Radiographic examination of extremities in surgical lengthening and/or correction of deformities is of crucial importance for the assessment of new bone formation. The purpose of this study is to confirm the diagnostic value of radiography in precise detection of bone parameters in various lengthening or correction stages in patients treated by limb-lengthening and deformity correction. 50 patients were treated by the Ilizarov method of limb lengthening or deformity correction at the University Orthopaedic Surgery Clinic in Skopje, and analysed over the period from 2006 to 2012. The patients were divided into two groups. The first group consisted of 27 patients with limb-lengthening because of congenital shortening. The second group consisted of 23 patients treated for acquired limb deformities. The results in both groups were received in three stages of new bone formation and were based on the appearance of 3 radiographic parameters at the distraction/compression site. The differences between the presence of all radiographic bone parameters in different stages of new bone formation were statistically signficant in both groups, especially the presence of the cortical margin in the first group (Cochran Q=34.43, df=2, p=0.00000). The comparative analysis between the two groups showed a statistically significant difference in the presence of initial bone elements and cystic formations only in the first stage. Almost no statistical significance in the differences between both groups of patients with regard to 3 radiographic parameters in 3 stages of new bone formation, indicates a minor influence of the etiopathogenetic background on the new bone formation in patients treated by gradual lengthening or correction of limb deformities.

  6. Congenital lumbar spinal stenosis: a prospective, control-matched, cohort radiographic analysis.

    Science.gov (United States)

    Singh, Kern; Samartzis, Dino; Vaccaro, Alexander R; Nassr, Ahmad; Andersson, Gunnar B; Yoon, S Tim; Phillips, Frank M; Goldberg, Edward J; An, Howard S

    2005-01-01

    Degenerative lumbar spinal stenosis manifests primarily after the sixth decade of life as a result of facet hypertrophy and degenerative disc disease. Congenital stenosis, on the other hand, presents earlier in age with similar clinical findings but with multilevel involvement and fewer degenerative changes. These patients may have subtle anatomic variations of the lumbar spine that may increase the likelihood of thecal sac compression. However, to the authors' knowledge, no quantitative studies have addressed various radiographic parameters of symptomatic, congenitally stenotic individuals to normal subjects. To radiographically quantify and compare the anatomy of the lumbar spine in symptomatic, congenitally stenotic individuals to age- and sex-matched, asymptomatic, nonstenotic controlled individuals. A prospective, control-matched, cohort radiographic analysis. Axial and sagittal magnetic resonance imaging (MRI) and lateral, lumbar, plain radiographs of 20 surgically treated patients who were given a clinical diagnosis of congenital lumbar stenosis by the senior author were randomized with images of 20, asymptomatic age- and sex-matched subjects. MRIs and lateral, lumbar, plain radiographs were independently quantitatively assessed by two individuals. Measurements obtained from the axial MRIs included: midline anterior-posterior (AP) vertebral body diameter, vertebral body width, midline AP canal diameter, canal width, spinal canal cross-sectional area, pedicle length, and pedicle width. From the sagittal MRIs, the following measurements were calculated: AP vertebral body diameter, vertebral body height, and AP canal diameter at the mid-vertebral level. On the lateral, lumbar, plain radiograph (L3 level), the AP diameters of the vertebral body spinal canal were measured. The images of these 40 individuals were then randomized and distributed in a blinded fashion to five separate spine surgeons who graded the presence and severity of congenital stenosis

  7. Preliminary analysis of doses to evaluate the image quality in radiographic examinations in veterinary radiology

    International Nuclear Information System (INIS)

    Pinto, Ana Carolina B.C.F.; Dias, Mayara T.P.; Santos, Andrea C.; Melo, Camila S.; Furquim, Tania A.C.

    2009-01-01

    This work has as objective to promote the analysis of the radiological doses and quality of the image of the technical letter used for the accomplishment of thorax and coxal radiographic examination of animals of canine and feline species. The study was accomplished in the service of Diagnosis for Image in Veterinarian Hospital of Veterinary Medicine and Zootecnia College of University of Sao Paulo, in two conventional equipment. Initially, physical features of the animals and the technique used were collected for each one of the 188 radiographic examinations of thorax and 52 examinations of coxal. The animals were placed in different groups, according to their body weight. For each group, the averages for each feature were calculated: thickness of the radiographed region, tension, electric current, time of exhibition, current product electric-time, size of the used film, presence or absence of bucky and feature of focus (narrow or thick). On the basis of the averages of group M (of lesser weights that 5kg for cats and between 10,1kg and 20kg for dogs), was executed a physical analysis of the current technical letter, using the equipment: ionization chamber (to determinate the value of kerma in air), simulator objects (representative of the thickness of the animal) and three dispositive standards of test that evaluate space resolution, resolution in low contrast and contrast-detail. The obtained images were analyzed and compared for a physicist and a radiologist medical veterinary. The results had shown that the examinations supply dose considered high for techniques used mainly for coxal. The equipment A, although to supply higher doses, presents the better images for the majority of the projections. However, the study indicates that there are not exactly reference levels, but these examinations must pass for improvement of quality of image (author)

  8. Radiographic evaluation of INBONE total ankle arthroplasty: a retrospective analysis of 30 cases

    International Nuclear Information System (INIS)

    Datir, Abhijit; Xing, Minzhi; Kakarala, Aparna; Terk, Michael R.; Labib, Sameh A.

    2013-01-01

    The objectives of this work were to retrospectively describe the radiographic assessment of INBONE total ankle arthroplasty in 30 patients using validated linear and angular measurements and to correlate these findings with the final surgical outcome over a 2-year follow-up period. Thirty consecutive patients (21 females, nine males; mean age, 64.8 years) underwent INBONE total ankle arthroplasty during 2007-2011. After IRB approval, a retrospective pre- and post-operative radiographic analysis was performed using validated linear and angular measurements. The pre- and post-operative assessment included the tibial angle, talar angle, tibial slope, and coronal deformity. Post-operative measurements also included the talocalcaneal angle, joint space height, talar height, lateral tibial component angle, lateral talar component angle, and anteroposterior tibial component angle. The post-operative bone loss, subluxation, positioning, and subsidence were also assessed. Statistical analysis was performed using two-sample t test and Fisher's exact test. Out of 30 patients, 23 had a successful clinical outcome with intact prosthesis at a 2-year follow-up. The only variables with significant correlation (p < 0.05) to the post-surgical outcome were the lateral talar component angle (p = 0.002) and the mean difference between pre- and post-operative tibial slope (p = 0.001). The coronal deformity had significant mean difference between pre- and post-operative values (p < 0.001); however, it lacked a significant correlation to the final surgical outcome. None of the categorical variables had a significant correlation with post-surgical outcome. In our retrospective study, only the lateral talar component angle and the mean difference between the pre- and post-operative tibial slope had significant correlation with post-surgical outcome in INBONE ankle arthroplasty. These measurements may be helpful in radiographic assessment of the INBONE ankle arthroplasty. (orig.)

  9. AFROC analysis of reporting radiographer's performance in CT head interpretation

    International Nuclear Information System (INIS)

    Lockwood, P.; Piper, K.

    2015-01-01

    Aim: A preliminary small scale study to assess the diagnostic performance of a limited group of reporting radiographers and consultant radiologists in clinical practice undertaking computed tomography (CT) head interpretation. Method: A multiple reader multiple case (MRMC) alternative free response receiver operating characteristic (AFROC) methodology was applied. Utilising an image bank of 30 CT head examinations, with a 1:1 ratio of normal to abnormal cases. A reference standard was established by double reporting the original reports using two additional independent consultant radiologists with arbitration of discordance by the researcher. Twelve observers from six southern National Health Service (NHS) trusts were invited to participate. The results were compared for accuracy, agreement, sensitivity, specificity. Data analysis used AFROC and area under the curve (AUC) with standard error. Results: The reporting radiographers results demonstrated a mean sensitivity rate of 88.7% (95% CI 82.3–95.1%), specificity 95.6% (96% CI 90.1–100%) and accuracy of 92.2% (95% CI 89.3–95%). The consultant radiologists mean sensitivity rate was 83.35% (95% CI 80–86.7%), specificity 90% (95% CI 86.7–93.3%) and accuracy of 86.65% (95% CI 83.3–90%). Observer performance between the two groups was compared with AFROC, AUC, and standard error analysis (p = 0.94, SE 0.202). Conclusion: The findings of this research indicate that within a limited study, a small group of reporting radiographers demonstrated high levels of diagnostic accuracy in the interpretation of CT head examinations that was equivalent to a small selection of consultant radiologists. - Highlights: • We assessed reporting radiographers and consultant radiologists in a clinical setting. • This was a small scale retrospective multi-reader multi-case multi-site study. • AFROC used lesion-based decisions rather than case-based decisions. • Within a limited study the observed performance was high in

  10. Image analysis of bubble behavior in the pressurized fluidized bed using neutron radiograph

    International Nuclear Information System (INIS)

    Katoh, Yasuo; Miyamoto, Masahide; Miike, Hidetoshi; Kishimoto, Yasuyuki; Matsubayasi, Masahito; Mochiki, Kouichi.

    1996-01-01

    It is very important to know about the formation for bubble production growth and destruction. Because blowing gas nozzle decide the ability of the solid-gas fluidized bed system. For the pressurized 3-D fluidized bed, it was some interested in the bubble production and configuration which was taken place the interaction between bubble and particle under the pressurized condition. For the understanding of the three dimensional characteristics of production bubble under pressurized condition, the study of visualization of neutron radiograph seemed to be useful. In stead of typical X-ray visualization method, visualization of neutron radiograph method for observation of bubble behavior were carried out. Then an image analysis of it was done the same way as two dimension method P-system (PIAS-LA555WS Image Analysis). As the results, the characteristic of production bubble was more clear quantitatively, for example, the bubble production frequency, the bubble diameter and the bubble horizontal and vertical sizes so on. (author)

  11. Radiographic evaluations

    International Nuclear Information System (INIS)

    Williams, J.L.

    1988-01-01

    The author describes how to: perform a systematic evaluation of a chest radiograph; state the classic radiographic description of hyaline membrane disease; list the conditions that cause hyperaeration and describe the radiologic feature of hyperaeration; describe the radiograph of a patient with a congenital diaphragmatic hernia; identify optimum placement of an endotracheal tube, gastric feeding tube, and umbilical artery catheter on a radiograph; differentiate between pulmonary interstitial air and hyaline membrane disease; select radiographic features that would indicate the presence of a tension pneumothorax; describe a lateral decubitus projection and state the type of problem it is most often used to identify; explain the procedure used in obtaining a lateral neck radiograph and list two problems that may require this view; and describe the radiograph of a patient with cystic fibrosis

  12. Texture analysis of trabecular bone using conventional radiographs: medical imaging and osteoporosis

    International Nuclear Information System (INIS)

    Karunanithi, R.; Panicker, T.M.R.; Paul Korath, M.; Jagadeesan, K.; Ganesan, S.

    2008-01-01

    Osteoporosis is characterized by reduced bone mass, microstructural deterioration with advancing age, and an increase in fracture risk. The accurate clinical assessment of bone strength and fracture risk is important for management of bone loss diseases such as osteoporosis risk. From a clinical point of view, microarchitecture is an interesting aspect to study and define patterns of bone alterations with aging and pathology. Microarchitecture seems to be a determinant of bone fragility independent of bone density. Moreover, bone microarchitecture seems to be important to understand the mechanisms of bone fragility independent of bone density. Moreover bone microarchitecture seems to be important to understand the mechanisms of bone fragility as well as the action of the drugs used to prevent osteoporotic fractures. In the case of osteoporosis the bone texture of the trabecular network as it appears on the plain radiographs can be quantified by applying image processing tools. Among the factors conditioning bone strength and osteoporotic fractures, bone mineral density is the most important and the best studied. Though, other factors also play a role: macroarchitecture of bones, cortical thickness, quality of bone crystal and of collagen network and trabecular microarchitecture. The microarchitecture plays a major role, and is an aspect of the definition of osteoporosis. Therefore, it would be very helpful if these alterations could be measured in addition to bone mineral density with noninvasive techniques, such as radiographs, and to assess the status of the bone by texture analysis

  13. Voice stress analysis and evaluation

    Science.gov (United States)

    Haddad, Darren M.; Ratley, Roy J.

    2001-02-01

    Voice Stress Analysis (VSA) systems are marketed as computer-based systems capable of measuring stress in a person's voice as an indicator of deception. They are advertised as being less expensive, easier to use, less invasive in use, and less constrained in their operation then polygraph technology. The National Institute of Justice have asked the Air Force Research Laboratory for assistance in evaluating voice stress analysis technology. Law enforcement officials have also been asking questions about this technology. If VSA technology proves to be effective, its value for military and law enforcement application is tremendous.

  14. Medullar fat influences texture analysis of trabecular microarchitecture on X-ray radiographs

    International Nuclear Information System (INIS)

    Chappard, Daniel; Pascaretti-Grizon, Florence; Gallois, Yves; Mercier, Philippe; Basle, Michel F.; Audran, Maurice

    2006-01-01

    Alteration of trabecular architecture is a predictor of fracture risk in osteoporosis. Until now, microarchitecture analysis is difficult to evaluate in routine clinical practice for osteoporosis. Texture analysis on X-ray images has been advocated to be a suitable method to assess microarchitecture in bone diseases. The X-ray acquisition conditions have been often taken into consideration; however, the influence of anatomical conditions on texture parameters has received little interest. Because fat is a well-known problem with computed tomography and densitometry, we have designed a cadaver study to compare the influence of marrow lipids on numerous texture parameters. Twenty-one human distal radii were obtained, radiographed, and analyzed using a software that measures: heterogeneity, skeletonized parameters, run-lengths and fractal dimensions. Texture parameters were measured before, and after an extensive delipidation period lasting 3 weeks. Quality of the radiographs was improved after defatting. Delipidation had a very significant effect on measurements: afterwards defatting, the images were less blurred, and a better delineation of trabeculae and marrow cavities was obtained. This provoked an increase of parameters based on the grey level distribution but had no influence on parameters describing the reticulated honeycomb microarchitecture of the trabeculae (i.e., fractal dimension). Some parameters appeared anisotropy-sensitive, due to the different constitution and size of the trabeculae. The fat content of bone marrow induces noise that can modify some texture parameters. One should take into account the fat content of the marrow when using texture analysis to compare patients with osteoporosis due to various etiologies

  15. Analysis of biological tissues in infant chest for the development of an equivalent radiographic phantom

    International Nuclear Information System (INIS)

    Pina, D. R.; Souza, Rafael T. F.; Duarte, Sergio B.; Alvarez, Matheus; Miranda, Jose R. A.

    2012-01-01

    Purpose: The main purpose of the present study was to determine the amounts of different tissues in the chest of the newborn patient (age ≤1 year), with the aim of developing a homogeneous phantom chest equivalent. This type of phantom is indispensable in the development of optimization procedures for radiographic techniques, including dosimetric control, which is a crucial aspect of pediatric radiology. The authors present a systematic set of procedures, including a computational algorithm, to estimate the amounts of tissues and thicknesses of the corresponding simulator material plates used to construct the phantom. Methods: The Gaussian fit of computed tomographic (CT) analysis was applied to classify and quantify different biological tissues. The methodology is summarized with a computational algorithm, which was used to quantify tissues through automated CT analysis. The thicknesses of the equivalent homogeneous simulator material plates were determined to construct the phantom. Results: A total of 180 retrospective CT examinations with anterior-posterior diameter values ranging 8.5-13.0 cm were examined. The amounts of different tissues were evaluated. The results provided elements to construct a phantom to simulate the infant chest in the posterior-anterior or anterior-posterior (PA/AP) view. Conclusions: To our knowledge, this report represents the first demonstration of an infant chest phantom dedicated to the radiology of children younger than one year. This phantom is a key element in the development of clinical charts for optimizing radiographic technique in pediatric patients. Optimization procedures for nonstandard patients were reported previously [Pina et al., Phys. Med. Biol. 49, N215-N226 (2004) and Pina et al., Appl. Radiat. Isot. 67, 61-69 (2009)]. The constructed phantom represents a starting point to obtain radiologic protocols for the infant patient.

  16. Concept Analysis: Alzheimer's Caregiver Stress.

    Science.gov (United States)

    Llanque, Sarah; Savage, Lynette; Rosenburg, Neal; Caserta, Michael

    2016-01-01

    The aim of this article was to analyze the concept of caregiver stress in the context of caring for a person with Alzheimer's disease and related dementias. Currently, there are more than 15 million unpaid caregivers for persons suffering from Alzheimer's disease and related dementias. This unpaid care can be stressful for caregivers due to the chronic nature of the disease process, as well as other factors. The paper incorporates the modified method of Wilson's concept analysis procedure to analyze the concept of caregiver stress. A review of the literature was undertaken using the Cumulative Index to Nursing and Allied Health Literature, Google Scholar, and PubMed. A theoretical definition of caregiver stress is provided, and the defining attributes, related concepts, antecedents, and consequences of caregiver stress are proposed, and case studies are presented. The analysis demonstrates that caregiver stress is the unequal exchange of assistance among people who stand in close relationship to one another, which results in emotional and physical stress on the caregiver. Implications for future nursing research and practice conclude the paper. © 2014 Wiley Periodicals, Inc.

  17. PDX vacuum vessel stress analysis

    International Nuclear Information System (INIS)

    Nikodem, Z.D.

    1975-01-01

    A stress analysis of PDX vacuum vessel is described and the summary of results is presented. The vacuum vessel is treated as a toroidal shell of revolution subjected to an internal vacuum. The critical buckling pressure is calculated. The effects of the geometrical discontinuity at the juncture of toroidal shell head and cylindrical outside wall, and the concavity of the cylindrical wall are examined. An effect of the poloidal field coil supports and the vessel outside supports on the stress distribution in the vacuum vessel is determined. A method evaluating the influence of circular ports in the vessel wall on the stress level in the vessel is outlined

  18. Stress analysis of pressure vessels

    International Nuclear Information System (INIS)

    Kim, B.K.; Song, D.H.; Son, K.H.; Kim, K.S.; Park, K.B.; Song, H.K.; So, J.Y.

    1979-01-01

    This interim report contains the results of the effort to establish the stress report preparation capability under the research project ''Stress analysis of pressure vessels.'' 1978 was the first year in this effort to lay the foundation through the acquisition of SAP V structural analysis code and a graphic terminal system for improved efficiency of using such code. Software programming work was developed in pre- and post processing, such as graphic presentation of input FEM mesh geometry and output deformation or mode shope patterns, which was proven to be useful when using the FEM computer code. Also, a scheme to apply fracture mechanics concept was developed in fatigue analysis of pressure vessels. (author)

  19. Normal left ventricular emptying in coronary artery disease at rest: analysis by radiographic and equilibrium radionuclide ventriculography

    International Nuclear Information System (INIS)

    Denenberg, B.S.; Makler, P.T.; Bove, A.A.; Spann, J.F.

    1981-01-01

    The volume ejected early in systole has been proposed as an indicator of abnormal left ventricular function that is present at rest in patients with coronary artery disease with a normal ejection fraction and normal wall motion. The volume ejected in systole was examined by calculating the percent change in ventricular volume using both computer-assisted analysis of biplane radiographic ventriculograms at 60 frames/s and equilibrium gated radionuclide ventriculograms. Ventricular emptying was examined with radiographic ventriculography in 33 normal patients and 23 patients with coronary artery disease and normal ejection fraction. Eight normal subjects and six patients with coronary artery disease had both radiographic ventriculography and equilibrium gated radionuclide ventriculography. In all patients, there was excellent correlation between the radiographic and radionuclide ventricular emptying curves (r . 0.971). There were no difference in the ventricular emptying curves of normal subjects and patients with coronary artery disease whether volumes were measured by radiographic or equilibrium gated radionuclide ventriculography. It is concluded that the resting ventricular emptying curves are identical in normal subjects and patients with coronary artery disease who have a normal ejection fraction and normal wall motion

  20. Mammography in breast cancer screening. A radiographic analysis of the carcinomas found at Utrecht, Nijmegen and Kopparberg county

    International Nuclear Information System (INIS)

    Muller, J.W.T.

    1985-01-01

    Population-based screening for carcinoma of the breast by mammography has yielded an abundance of data, not all of which have been processed yet, the mammographic (radiographic) data in particular. The present study concerns an analysis of the mammographic signs in the histologically proven carcinomas (invasive and intraductal) detected by these three screening programs. The radiographic signs of the screened carcinomas were compared with those of the clinical carcinomas diagnosed in the Utrecht University Hospital (to be called AZU carcinomas). These AZU carcinomas were taken as reference material, and were therefore analysed in the same way as the screening material. (Auth.)

  1. Radiographic testing

    International Nuclear Information System (INIS)

    Kuster, J.

    1978-01-01

    In view of great differencies in X-ray transmission it is more difficult to get optimum radiographs of plastics and especially of reinforced plastics than for example of metals. A procedure will be reported how to get with little effort optimum radiographs especially also in the range of long wave-length radiation corresponding 10 to 25 kV.P. (orig.) [de

  2. Comparative analysis between radiographic views for knee osteoarthrosis (bipedal AP versus monopedal AP

    Directory of Open Access Journals (Sweden)

    Rodrigo Pires e Albuquerque

    2013-08-01

    Full Text Available OBJECTIVE: A comparative analysis by applying the criteria of the original classification Ahlbäck in the anteroposterior (AP bipedal knee in extension and anteroposterior (AP monopodal knee in symptomatic knee arthrosis. With this analysis we intend to observe the agreement, any advantage or difference between the incidence and degree of joint involvement between the orthopedic surgeons and radiologists with the referring physician. METHODS: From January 2012 to March 2012, was a prospective study of 60 symptomatic arthrosis knees (60 patients, clinically selected group of outpatient knee and radiographic proposals submitted to the search. Of the 60 patients, 39 were female and 21 male, mean age 64 years (ranging from 50 to 84 years. Of the 60 knees studied, 37 corresponded to the right side and 23 on the left side. Statistical analysis was performed by Kappa statistics, which evaluates the interobserver agreement for qualitative data. RESULTS: According to the scale of Ahlbäck, there was a significant agreement (p < 0.0001 intra-observer in the classification of knee osteoarthritis among the five evaluators. There was a significant agreement (p < 0.0001 with inter-observer referring physician in the incidence of AP monopodal and AP bipedal for the four raters. CONCLUSION: The study found no difference between the incidence in the AP monopodal versus AP bipedal in osteoarthritis of the knee.

  3. Correlation between radiographic analysis of alveolar bone density around dental implant and resonance frequency of dental implant

    Science.gov (United States)

    Prawoko, S. S.; Nelwan, L. C.; Odang, R. W.; Kusdhany, L. S.

    2017-08-01

    The histomorphometric test is the gold standard for dental implant stability quantification; however, it is invasive, and therefore, it is inapplicable to clinical patients. Consequently, accurate and objective alternative methods are required. Resonance frequency analysis (RFA) and digital radiographic analysis are noninvasive methods with excellent objectivity and reproducibility. To analyze the correlation between the radiographic analysis of alveolar bone density around a dental implant and the resonance frequency of the dental implant. Digital radiographic images for 35 samples were obtained, and the resonance frequency of the dental implant was acquired using Osstell ISQ immediately after dental implant placement and on third-month follow-up. The alveolar bone density around the dental implant was subsequently analyzed using SIDEXIS-XG software. No significant correlation was reported between the alveolar bone density around the dental implant and the resonance frequency of the dental implant (r = -0.102 at baseline, r = 0.146 at follow-up, p > 0.05). However, the alveolar bone density and resonance frequency showed a significant difference throughout the healing period (p = 0.005 and p = 0.000, respectively). Conclusion: Digital dental radiographs and Osstell ISQ showed excellent objectivity and reproducibility in quantifying dental implant stability. Nonetheless, no significant correlation was observed between the results obtained using these two methods.

  4. A comparative analysis of emotional intelligence in the UK and Australian radiographer workforce

    International Nuclear Information System (INIS)

    Mackay, S.J.; Baker, R.; Collier, D.; Lewis, S.

    2013-01-01

    Emotional intelligence (EI) in the UK radiographer workforce has been benchmarked using the trait emotional intelligence model and the profile of the profession in the UK has begun to emerge. There are cultural differences between countries that have been shown to have an effect on EI, therefore this paper aims to benchmark the Global and four factor scores of Trait EI in the Australian radiographer population; to explore any differences within the two main professional groupings, diagnostic and therapeutic radiographers, and to compare the Australian radiographer workforce scores with those of the UK previously published. The published and validated trait EI questionnaire of Petrides was used as the survey tool for the Global EI and the four factors of Well-being, Emotionality, Self-control and Sociability. There was only one difference found in the five factors studied between the UK and Australian radiographer workforce, that of Well-being (p ≤ 0.01). No differences emerged between the diagnostic and therapy disciplines nor was a relationship found between EI and the Australian leadership in contrast to the UK workforce findings. Differences were found in the demographic profiles of the two countries and the implications of the above findings are discussed. This paper has benchmarked the EI of the Australian workforce and found a difference in well-being between the UK and Australian radiographer workforce. The Australian diagnostic and therapy disciplines were no different in their EI profiles. No relationship was found between EI and leadership in the Australian radiographer workforce

  5. Identification of 'Point A' as the prevalent source of error in cephalometric analysis of lateral radiographs.

    Science.gov (United States)

    Grogger, P; Sacher, C; Weber, S; Millesi, G; Seemann, R

    2018-04-10

    Deviations in measuring dentofacial components in a lateral X-ray represent a major hurdle in the subsequent treatment of dysgnathic patients. In a retrospective study, we investigated the most prevalent source of error in the following commonly used cephalometric measurements: the angles Sella-Nasion-Point A (SNA), Sella-Nasion-Point B (SNB) and Point A-Nasion-Point B (ANB); the Wits appraisal; the anteroposterior dysplasia indicator (APDI); and the overbite depth indicator (ODI). Preoperative lateral radiographic images of patients with dentofacial deformities were collected and the landmarks digitally traced by three independent raters. Cephalometric analysis was automatically performed based on 1116 tracings. Error analysis identified the x-coordinate of Point A as the prevalent source of error in all investigated measurements, except SNB, in which it is not incorporated. In SNB, the y-coordinate of Nasion predominated error variance. SNB showed lowest inter-rater variation. In addition, our observations confirmed previous studies showing that landmark identification variance follows characteristic error envelopes in the highest number of tracings analysed up to now. Variance orthogonal to defining planes was of relevance, while variance parallel to planes was not. Taking these findings into account, orthognathic surgeons as well as orthodontists would be able to perform cephalometry more accurately and accomplish better therapeutic results. Copyright © 2018 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Orthodontic and dysfunctional abnormalities of stomatognatic apparatus: radiographic analysis of 204 subjects

    International Nuclear Information System (INIS)

    Scutellari, P.N.; Capurso, V.; Rotolo, R.; Calura, G.; Orzincolo, C.

    1990-01-01

    Two hundred and four subjects (86 males and 118 females), aged 8 to 35 years, with different types of malocclusion, underwent panoramic dental radiography and skull teleradiography. This study was aimed at investigating advantages and limitations of the two radiographic techniques, in view of their use as screening methods. On orthopan-tomography, inferior interincisive point, menthon (Me), and, bilaterally, gonion (Go) and condilion (Co), were localized so as to allow a model of the right and left jaws to be made. On teleradiography of the skull, in lateral view, Steiner's cephalometric analysis allowed skeletal classes to be evaluated according to ANB angle values. More-over, major postural parameters relative to the relationship between skull and cervical spine were analyzed: atlanto-occipital distance, cranio-vertebral angle, cervical lordosis, and hyoid triangle. Orthopan-tomography, though not a reproducible technique, can be considered as a valuable screening method for it allows right and left hemi-jaws to be comparatively measured. Cephalometric analysis of postural data confirmed the frequency of wrong postures in orthodontic patients. From the correlation of mandibular asymmetries and cranio-cervical parameters, the authors observed that asymmetrical patients have many postural problems, just like class II skeletal and dolico-facial types. This findings seems to confirm the mixed (functional and skeletal) etiopathogenesis of mandibular asymmetries

  7. Analysis the findings of chest radiograph and CT scan in 217 acute thoracic trauma

    International Nuclear Information System (INIS)

    Huang Shaoying

    2005-01-01

    Objective: To evaluate chest radiograph and CT scan in assessing acute thoracic trauma. Methods: Retrospectively analyzed the findings of chest radiograph and CT scan in 217 cases of acute thoracic trauma and positive rate of each modality was compared. Results: The positive rate of rib and clavicle fracture was higher in chest radiograph than these in CT scan. But the positive rate of chest wall hematoma, mediastinum and subcutaneous emphysema, pneumothorax, hydropneumothorax, damage of lung parenchyma and traumatic pulmonary atelectasis was higher in CT scan than those in chest radiograph. Conclusion: The application of the combined imaging modalities improves assessing of acute thoracic trauma, because the imaging manifestation of the lesion is various. (authors)

  8. Radiographic positioning

    International Nuclear Information System (INIS)

    Eisenberg, R.L.; Dennis, C.A.; May, C.

    1989-01-01

    This book concentrates on the routine radiographic examinations commonly performed. It details the wide variety of examinations possible and their place in initial learning and in the radiology department as references for those occasions when an unusual examination is requested. This book provides information ranging from basic terminology to skeletal positioning to special procedures. Positions are discussed and supplemented with a picture of a patient, the resulting radiograph, and a labeled diagram. Immobilization and proper shielding of the patient are also shown

  9. Radiographic Test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H.J; Yang, S.H. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    This report contains theory, procedure technique and interpretation of radiographic examination and written for whom preparing radiographic test Level II. To determine this baseline of technical competence in the examination, the individual must demonstrate a knowledge of radiography physics, radiation safety, technique development, radiation detection and measurement, facility design, and the characteristics of radiation-producing devices and their principles of operation. (author) 98 figs., 23 tabs.

  10. Knee Images Digital Analysis (KIDA): a novel method to quantify individual radiographic features of knee osteoarthritis in detail.

    Science.gov (United States)

    Marijnissen, A C A; Vincken, K L; Vos, P A J M; Saris, D B F; Viergever, M A; Bijlsma, J W J; Bartels, L W; Lafeber, F P J G

    2008-02-01

    Radiography is still the golden standard for imaging features of osteoarthritis (OA), such as joint space narrowing, subchondral sclerosis, and osteophyte formation. Objective assessment, however, remains difficult. The goal of the present study was to evaluate a novel digital method to analyse standard knee radiographs. Standardized radiographs of 20 healthy and 55 OA knees were taken in general practise according to the semi-flexed method by Buckland-Wright. Joint Space Width (JSW), osteophyte area, subchondral bone density, joint angle, and tibial eminence height were measured as continuous variables using newly developed Knee Images Digital Analysis (KIDA) software on a standard PC. Two observers evaluated the radiographs twice, each on two different occasions. The observers were blinded to the source of the radiographs and to their previous measurements. Statistical analysis to compare measurements within and between observers was performed according to Bland and Altman. Correlations between KIDA data and Kellgren & Lawrence (K&L) grade were calculated and data of healthy knees were compared to those of OA knees. Intra- and inter-observer variations for measurement of JSW, subchondral bone density, osteophytes, tibial eminence, and joint angle were small. Significant correlations were found between KIDA parameters and K&L grade. Furthermore, significant differences were found between healthy and OA knees. In addition to JSW measurement, objective evaluation of osteophyte formation and subchondral bone density is possible on standard radiographs. The measured differences between OA and healthy individuals suggest that KIDA allows detection of changes in time, although sensitivity to change has to be demonstrated in long-term follow-up studies.

  11. Injuries of the trochanteric region: can analysis of radiographic indices help in prediction of recurrent osteoporotic hip fractures?

    Science.gov (United States)

    Pellegrini, Andrea; Tacci, Fabrizio; Leigheb, Massimiliano; Costantino, Cosimo; Pedrazzini, Alessio; Pedrazzi, Giuseppe; Vaienti, Enrico; Ceccarelli, Francesco; Pogliacomi, Francesco

    2017-10-18

    In a context of bone fragility, primitive and subsequent fractures are a growing problem in the industrialized countries where the mean age of the population is constantly increasing. Among the various factors that favor a fragility fracture, the most important is osteoporosis, a pathology that can be prevented through diagnostic screenings and treated by pharmacological and rehabilitative therapies. The aim of this study is to identify the subjects who are likely to have a higher risk of subsequent fractures of the trochanteric region through a retrospective radiographic evaluation of patients affected by low-energy trochanteric fractures and operated by intramedullary fixation between June 2013 and June 2015, so they can be targeted for prevention interventions. Three hundred and sixty-one patients yet alive were analyzed 2 years after surgery. Fifty-one (group 1), characterized by another contralateral trochanteric femoral fracture, were included. All subjects were retrospectively examined with the analysis of contralateral femur X-ray performed at the time of initial trauma in order to detect a condition of bone fragility and a predisposition to fractures by evaluating three radiographic indices (Singh index, Dorr's classification and Cortical Thickness Index). Patients of group 1 were compared to the other 310 patients (group 2) affected by isolated trochanteric fracture. Group 1 had all radiographic indices worse than group 2. The results observed suggest that orthopedists can use radiographic indices, in particular Cortical Thickness Index, as a valuable, simple and inexpensive screening tool for prevention of recurrent osteoporotic fractures.

  12. Diagnostic yield of ink-jet prints from digital radiographs for the assessment of approximal carious lesions: ROC-analysis

    International Nuclear Information System (INIS)

    Schulze, Ralf K.W.; Grimm, Stefanie; Schulze, Dirk; Voss, Kai; Keller, Hans-Peter; Wedel, Matthias

    2011-01-01

    Aims: To investigate the diagnostic quality of different quality, individually calibrated ink-jet printers for the very challenging dental radiographic task of approximal carious lesion detection. Materials and methods: A test-pattern evaluating resolution, contrast and homogeneity of the ink-jet prints was developed. 50 standardized dental radiographs each showing two neighbouring teeth in natural contact were printed on glossy paper with calibrated, randomly selected ink-jet printers (Canon S520 and iP4500, Epson Stylus Photo R2400). Printing size equalled the viewing size on a 17'' cathode-ray-tube monitor daily quality-tested according to German regulations. The true caries status was determined from serial sectioning and microscopic evaluation. 16 experienced observers evaluated the radiographs on a five-point confidence scale on all prints plus the viewing monitor with respect to the visibility of a carious lesion. A non-parametric Receiver-Operating Characteristics (ROC-) analysis was performed explicitly designed for the evaluation of readings stemming from identical samples but different modality. Significant differences are expressed by a critical ratio z exceeding ±2. Diagnostic accuracy was determined by the area (Az) underneath the ROC-curves. Results: Average Az-values ranged between 0.62 (S520 and R2400) and 0.64 (monitor, iP4500), with no significant difference between modalities (P = 0.172). Neither significant (range mean z: -0.40 (S520) and -0.11 (iP4500)) nor clinically relevant differences were found between printers and viewing monitor. Conclusions: Our results for a challenging task in dental radiography indicate that calibrated, off-the-shelf ink-jet printers are able to reproduce (dental) radiographs at quality levels sufficient for radiographic diagnosis in a typical dental working environment.

  13. Diagnostic yield of ink-jet prints from digital radiographs for the assessment of approximal carious lesions: ROC-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, Ralf K.W., E-mail: rschulze@mail.uni-mainz.de [Poliklinik fuer Zahnaerztliche Chirurgie, University Medical Center of the Johannes Gutenberg-University, Augustusplatz 2, D-55131 Mainz (Germany); Grimm, Stefanie, E-mail: StefanieGrimm@gmx.de [Poliklinik fuer Zahnaerztliche Chirurgie, University Medical Center of the Johannes Gutenberg-University, Augustusplatz 2, D-55131 Mainz (Germany); Schulze, Dirk, E-mail: dirk.schulze@uniklinik-freiburg.de [Klinik fuer Mund,- Kiefer- und Gesichtschirurgie, Sektion Roentgen, Universitaetsklinikum Freiburg, Hugstetterstr. 55, D-79106 Freiburg (Germany); Voss, Kai, E-mail: zahnarzt@drvoss.eu [Zahnaerztekammer Schleswig-Holstein, Vorstand fuer Praxisfuehrung, Westring 496, D- 24106 Kiel (Germany); Keller, Hans-Peter, E-mail: hans-peter.keller@din.de [NA Dental (NADENT) im DIN, Alexander-Wellendorff-Str. 2, D-75172 Pforzheim (Germany); Wedel, Matthias, E-mail: matthias.wedel@siemens.com [Siemens AG, Medical Solutions, Postfach 32 60, D-91050 Erlangen (Germany)

    2011-08-15

    Aims: To investigate the diagnostic quality of different quality, individually calibrated ink-jet printers for the very challenging dental radiographic task of approximal carious lesion detection. Materials and methods: A test-pattern evaluating resolution, contrast and homogeneity of the ink-jet prints was developed. 50 standardized dental radiographs each showing two neighbouring teeth in natural contact were printed on glossy paper with calibrated, randomly selected ink-jet printers (Canon S520 and iP4500, Epson Stylus Photo R2400). Printing size equalled the viewing size on a 17'' cathode-ray-tube monitor daily quality-tested according to German regulations. The true caries status was determined from serial sectioning and microscopic evaluation. 16 experienced observers evaluated the radiographs on a five-point confidence scale on all prints plus the viewing monitor with respect to the visibility of a carious lesion. A non-parametric Receiver-Operating Characteristics (ROC-) analysis was performed explicitly designed for the evaluation of readings stemming from identical samples but different modality. Significant differences are expressed by a critical ratio z exceeding {+-}2. Diagnostic accuracy was determined by the area (Az) underneath the ROC-curves. Results: Average Az-values ranged between 0.62 (S520 and R2400) and 0.64 (monitor, iP4500), with no significant difference between modalities (P = 0.172). Neither significant (range mean z: -0.40 (S520) and -0.11 (iP4500)) nor clinically relevant differences were found between printers and viewing monitor. Conclusions: Our results for a challenging task in dental radiography indicate that calibrated, off-the-shelf ink-jet printers are able to reproduce (dental) radiographs at quality levels sufficient for radiographic diagnosis in a typical dental working environment.

  14. Mycoplasma pneumonia in children: radiographic pattern analysis and difference in resolution

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Myeong Ja; Jeong, Sung Eun; Kim, Joung Sook; Hur, Gham; Park, Jeung Uk [Inje Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-11-01

    By analysing frequency and disease progression, this study aimed to investigate and predict the prognosis of mycoplasma pneumonia according to radiographic pattern. We retrospectively reviewed plain chest radiographs of 230 patients in whom mycoplasm pneumonia had been serologically confirmed. Their age ranged from two months to 14 years and two months, and 203(88.3%) were younger than eight years. Radiographic patterns were classified as air space consolidation, bronchopneumonic, interstitial pneumonic or diffuse mixed infiltrating type. The radiologic resolution period for each type was analysed by the resolution of symptoms and normalization of radiologic findings. The bronchopneumonic type, which was the most common, was seen in 82 patients(35.6%), airspace consolidation in 58(25.2%), interstitial in 55(23.9%), and diffuse mixed in 22(9.57%). In thirteen patients(5.7%), chest radiographs were normal, though the clinical and radiologic resolution period for each type was variable. The mean resolution period of the air space consolidation type was 14.5 days, bronchopneumonic, 7.6 days ; interstitial, 10.5 days, and diffuse mixed, 15.6 days. The airspace consolidation type needed the longest recovery period, exceeded only by the diffuse mixed type. The bronchopneumonic type was the most common radiographic pattern of mycoplasma pneumonia. The prognosis of the airspace consolidation type seems to be poorest, since this required the longest recovery period.

  15. Acute chest syndrome of sickle cell disease: radiographic and clinical analysis of 70 cases

    International Nuclear Information System (INIS)

    Martin, L.; Buonomo, C.

    1997-01-01

    Background. Acute chest syndrome (ACS) is a pulmonary illness with fever, chest pain, leukocytosis and new pulmonary opacity in a patient with sickle cell disease. It is a common reason for hospitalization in sickle cell patients, and a significant cause of mortality. The etiology of ACS is unclear. Lung or bone infarction and infection, among other possible causes, have been proposed. Objective. We reviewed the chest radiographs and medical records of 41 patients with 70 episodes of ACS and correlated the clinical and radiographic courses in an attempt to better characterize and understand the syndrome. Results. In 87 % of episodes, no identifiable etiology of ACS was found. This group of patients had a median age of 14 years and showed dramatic clinical and radiographic improvement within 24 h of therapy. In the remainder of episodes (13 %), an identifiable etiology was found, usually bacterial pneumonia. These patients were younger than the group without an identifiable etiology (median age 2 years) and had a prolonged radiographic course of illness. Conclusion. The chest radiographs of children with ACS without an identifiable etiology have an extremely typical appearance and evolution. Only in cases which do not have this typical pattern should infection be suspected as the underlying cause. (orig.). With 3 figs

  16. Aortic stentgraft movement detection using digital roentgen stereophotogrammetric analysis on plane film radiographs - initial results of a phantom study

    International Nuclear Information System (INIS)

    Georg, C.; Welker, V.; Eidam, H.; Alfke, H.

    2005-01-01

    Purpose: To evaluate the feasibility of aortic stentgraft micromovement detection using digital roentgen stereophotogrammetric analysis on plane film radiographs. Material and Methods: An aortic stentgraft used for demonstration purposes was marked with 10 tantalum markers of 0.8 mm in diameter. The stentgraft was placed on a Plexiglas phantom with 5 tantalum markers of 1 mm in diameter simulating a fixed segment needed for mathematical analysis. In a subsequent step, the stentgraft was placed onto an orthopaedic spine model to simulate in vivo conditions in a next step.Two radiographs taken simultaneously from different angles were used for simulating different stentgraft movement, e.g. translation, angulation, aortic pulsation and migration in the spine model. Movement of the stentgraft markers was analysed using a commercially available digital RSA setup (UmRSA registered 4.1, RSA Biomedical, Umea, Sweden). Results: Our study shows the feasibility of measuring aortic stentgraft movement and changes in stentgraft shape in the submillimeter range using digital roentgen stereophotogrammetric analysis. Translation along the 3 cardinal axes, change in stentgraft shape, simulation of aortic pulsation and simulation of in vivo conditions could be described precisely. Conclusion: Aortic stentgraft movement detection using digital roentgen stereophotogrammetric analysis on plane film radiographs is a very promising, precise method. (orig.)

  17. Observer performance in detecting multiple radiographic signals: prediction and analysis using a generalized ROC approach

    International Nuclear Information System (INIS)

    Metz, C.E.; Starr, S.J.; Lusted, L.B.

    1975-01-01

    The theories of decision processes and signal detection provide a framework for the evaluation of observer performance. Some radiologic procedures involve a search for multiple similar lesions, as in gallstone or pneumoconiosis examinations. A model is presented which attempts to predict, from the conventional receiver operating characteristic (ROC) curve describing the detectability of a single visual signal in a radiograph, observer performance in an experiment requiring detection of more than one such signal. An experiment is described which tests the validity of this model for the case of detecting the presence of zero, one, or two low-contrast radiographic images of a two-mm.-diameter lucite bead embedded in radiographic mottle. Results from six observers, including three radiologists, confirm the validity of the model and suggest that human observer performance for relatively complex detection tasks can be predicted from the results of simpler experiments

  18. Experimental analysis of motion artifacts in chest radiographs with the AMBER system

    International Nuclear Information System (INIS)

    Boetticher, H. von; Hofmann, K.; Luska, G.

    1999-01-01

    The prerequisites, mechanisms and principles of motion artifacts in AMBER radiographs were analysed. The experiments were performed using metronomes, a moving conventional mammography phantom, and arrangements of oscillating coil spring, spheroid and grid elements. A diagnostic dosimeter and TLDs, respectively, were used to measure exposure times and doses. The deree of distortion in AMBER radiographs depends on the direction of the object movement relative to the AMBER fan beam in a complex manner. The size of the motion artifacts depends on the local exposure time. The maximum value of this time is 75 ms and thus 1.5 times higher than specified by the manufacturer. To interpret AMBER radiographs possible system specific artifacts have to be considered to avoid misinterpretations of potentially significant details. (orig.) [de

  19. A procedure for the evaluation of 2D radiographic texture analysis to assess 3D bone micro-architecture

    International Nuclear Information System (INIS)

    Apostol, L.; Peyrin, F.; Yot, S.; Basset, O.; Odet, Ch.; Apostal, L.; Peyrin, F.; Boller, E.; Tabary, J.; Dinten, J.M.; Boudousq, V.; Kotzki, P.O.

    2004-01-01

    Although the diagnosis of osteoporosis is mainly based on Dual X-ray Absorptiometry, it has been shown that trabecular bone micro-architecture is also an important factor in regards of fracture risk, which can be efficiently assessed in vitro using three-dimensional x-ray microtomography (μCT). In vivo, techniques based on high-resolution x-ray radiography associated to texture analysis have been proposed to investigate bone micro-architecture, but their relevance for giving pertinent 3D information is unclear. The purpose of this work was to develop a method for evaluating the relationships between 3D micro-architecture and 2D texture parameters, and optimizing the conditions for radiographic imaging. Bone sample images taken from cortical to cortical were acquired using 3D-synchrotron x-ray μCT at the ESRF. The 3D digital images were further used for two purposes: 1) quantification of three-dimensional bone micro-architecture, 2) simulation of realistic x-ray radiographs under different acquisition conditions. Texture analysis was then applied to these 2D radiographs using a large variety of methods (co-occurrence, spectrum, fractal...). First results of the statistical analysis between 2D and 3D parameters allowed identifying the most relevant 2D texture parameters. (authors)

  20. Fatigue stress fractures of the pubic ramus in the army: imaging features with radiographic, scintigraphic and MR imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Woo; Lee, Chang Hyun [The Armed Forces Capital Hospital, Seongnam (Korea, Republic of)

    2005-03-15

    Although fatigue fractures are not unusual in athletes and military personnel those of the pubic ramus are rare. We report three cases of fatigue fractures of the inferior pubic rami in two male recruits and one female military cadet. On the initial radiograph, most of the lesions were subtle and easy to overlook. However, bone scintigraphy provided more distinct images that allowed easy and early detection of lesion, and MR imaging presented more diagnostic information, which allowed a precise diagnosis.

  1. 14 CFR 33.62 - Stress analysis.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Stress analysis. 33.62 Section 33.62... STANDARDS: AIRCRAFT ENGINES Design and Construction; Turbine Aircraft Engines § 33.62 Stress analysis. A stress analysis must be performed on each turbine engine showing the design safety margin of each turbine...

  2. Assessment of the willingness of Australian radiographers in mammography to accept new responsibilities in role extension: Part two – qualitative analysis

    International Nuclear Information System (INIS)

    Moran, S.; Taylor, J.K.; Warren-Forward, H.

    2013-01-01

    Advanced practice in screening mammography has become widespread in the United Kingdom over the last 20 years, and Australian radiographers working in BreastScreen programs have shown interest in similar developments. Radiographers working in BreastScreen Australia were surveyed in order to capture their thoughts and perceptions on role extension. Questionnaires were circulated to radiographers working in BreastScreen Australia programs. Thematic analysis was used to analyze the open response questions to explore the advantages and disadvantages identified by the participants with respect to role expansion in screening mammography as well as any changes to their duties over the last decade. There were 253 responses to the survey and of those responses, 70% of radiographers shared their thoughts on role extension and 49% provided comments on changes in the workplace. The majority (61%) radiographers responding to the role extension question were concerned about potential problems associated with role extension; the biggest issues were that role extension should not be mandatory and that selection criteria for advanced practitioners should be stringent, with adequate time made available for training and study. The major change in the role of the radiographer has been the increased time dedicated to quality assurance tasks and administrative duties as well as more training required due to technological changes from film-screen to digital mammography. There is high interest in role extension by radiographers working in BreastScreen programs, provided that it is voluntary. The role of the radiographer within breast imaging in Australia is still evolving

  3. Reject analysis: A comparison of radiographer and radiologist perceptions of image quality

    International Nuclear Information System (INIS)

    Mount, J.

    2016-01-01

    This study explores the potential differences in perceptions of image quality between radiographers and radiologists in a large UK hospital and the subsequent impact this has on image rejection. Image rejection, while sometimes necessary, often leads to an increased radiation dose to the patient due to the need to repeat. Moreover, this translates into increased waiting times, departmental costs, and lower patient satisfaction. Adopting a mixed methods approach, this paper first seeks to quantify the differences in radiographer and radiologist perceptions and second establish the underlying causes of such differences through a quantitative and qualitative investigation respectively. Using a standardized psychometric scale of a GP lateral knee, the study reveals significant differences in the perceptions of quality and rejection rates between radiographers and radiologists driven by a conflict in the evaluation criteria used. The study has significant implications for improving departmental performance and proposes a potential solution for reducing reject rates and image repeats. - Highlights: • Significant differences are found to exist in perceptions of image quality. • Differences in perceptions of image quality directly influence reject rates. • Radiographers judge images on technical criteria. • Radiologists judge images on diagnostic criteria. • Results suggest better communication could reduce reject rates.

  4. Radiographic screening of edentulous patients: sense or nonsense? A risk-benefit analysis

    International Nuclear Information System (INIS)

    Keur, J.J.

    1986-01-01

    The benefits of radiographic examination of symptomless edentulous patients are presented. Based on data from the literature, an estimate of the risk of fatal malignancy from such a procedure is provided. Because the benefits are considerable and the risks low, a recommendation for selective screening of edentulous patients is made

  5. Presentation and analysis of radiographic data in clinical trials and observational studies

    NARCIS (Netherlands)

    Landewé, R.; van der Heijde, D.

    2005-01-01

    Despite the advent of sophisticated imaging systems, plain radiography continues to be a valuable outcome variable in clinical trials of inflammatory disorders for a number of reasons. This paper discusses the pros and cons of the different ways in which radiographic data in trials is presented; the

  6. Benchmarking the performance of fixed-image receptor digital radiographic systems part 1: a novel method for image quality analysis.

    Science.gov (United States)

    Lee, Kam L; Ireland, Timothy A; Bernardo, Michael

    2016-06-01

    This is the first part of a two-part study in benchmarking the performance of fixed digital radiographic general X-ray systems. This paper concentrates on reporting findings related to quantitative analysis techniques used to establish comparative image quality metrics. A systematic technical comparison of the evaluated systems is presented in part two of this study. A novel quantitative image quality analysis method is presented with technical considerations addressed for peer review. The novel method was applied to seven general radiographic systems with four different makes of radiographic image receptor (12 image receptors in total). For the System Modulation Transfer Function (sMTF), the use of grid was found to reduce veiling glare and decrease roll-off. The major contributor in sMTF degradation was found to be focal spot blurring. For the System Normalised Noise Power Spectrum (sNNPS), it was found that all systems examined had similar sNNPS responses. A mathematical model is presented to explain how the use of stationary grid may cause a difference between horizontal and vertical sNNPS responses.

  7. The radiographer-patient relationship: Enhancing understanding using a transactional analysis approach

    International Nuclear Information System (INIS)

    Booth, Lisa

    2008-01-01

    Purpose: Government initiatives such as the NHS Plan, the NHS Key Skills Framework and the NHS Career framework place communication at the centre of effective patient care, and role/career development. All advocate a patient-centred approach to dealing with patients, through open communication styles that encourage patients to become active participants in their care. Previous research, that has investigated communication in diagnostic radiography, demonstrated a preference for practitioner-centred, rather than patient-centred approaches to communication, however, there is little evidence to suggest why this should be the case or how a more patient-centred approach might be encouraged. The present study therefore sought to explore factors that influence communication in diagnostic radiography, with the view to understanding the barriers to patient-centred care. Method: Semi-structured group interviews took place with 12 radiographers, across two NHS trusts, with the aim of understanding their communication with patients and the factors that influence it. An open coding approach was used to analyse the data. Results: Four attitude categories were identified as influencing the communication used by diagnostic radiographers. 1. Characteristics of the radiographer. 2. Characteristics of the patient. 3. The need to produce a diagnostic image. 4. The need to keep the department running. Conclusion: Radiographer-patient communication is evidently influenced by these four attitude categories. If patient-centred styles of communication are to be encouraged, these factors need to be recognised and taken account of in the selection, education/training and workforce planning of diagnostic radiographers

  8. Animal radiographs

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This chapter presents historical x rays of a wide variety of animals taken within 5 years of the discovery of x radiation. Such photos were used as tests or as illustrations for radiographic publications. Numerous historical photographs are included. 10 refs

  9. Advanced Techniques of Stress Analysis

    Directory of Open Access Journals (Sweden)

    Simion TATARU

    2013-12-01

    Full Text Available This article aims to check the stress analysis technique based on 3D models also making a comparison with the traditional technique which utilizes a model built directly into the stress analysis program. This comparison of the two methods will be made with reference to the rear fuselage of IAR-99 aircraft, structure with a high degree of complexity which allows a meaningful evaluation of both approaches. Three updated databases are envisaged: the database having the idealized model obtained using ANSYS and working directly on documentation, without automatic generation of nodes and elements (with few exceptions, the rear fuselage database (performed at this stage obtained with Pro/ ENGINEER and the one obtained by using ANSYS with the second database. Then, each of the three databases will be used according to arising necessities.The main objective is to develop the parameterized model of the rear fuselage using the computer aided design software Pro/ ENGINEER. A review of research regarding the use of virtual reality with the interactive analysis performed by the finite element method is made to show the state- of- the-art achieved in this field.

  10. Meta-analysis of Clinical and Radiographic Outcomes After Arthroscopic Single-Row Versus Double-Row Rotator Cuff Repair.

    Science.gov (United States)

    Perser, Karen; Godfrey, David; Bisson, Leslie

    2011-05-01

    Double-row rotator cuff repair methods have improved biomechanical performance when compared with single-row repairs. To review clinical outcomes of single-row versus double-row rotator cuff repair with the hypothesis that double-row rotator cuff repair will result in better clinical and radiographic outcomes. Published literature from January 1980 to April 2010. Key terms included rotator cuff, prospective studies, outcomes, and suture techniques. The literature was systematically searched, and 5 level I and II studies were found comparing clinical outcomes of single-row and double-row rotator cuff repair. Coleman methodology scores were calculated for each article. Meta-analysis was performed, with treatment effect between single row and double row for clinical outcomes and with odds ratios for radiographic results. The sample size necessary to detect a given difference in clinical outcome between the 2 methods was calculated. Three level I studies had Coleman scores of 80, 74, and 81, and two level II studies had scores of 78 and 73. There were 156 patients with single-row repairs and 147 patients with double-row repairs, both with an average follow-up of 23 months (range, 12-40 months). Double-row repairs resulted in a greater treatment effect for each validated outcome measure in 4 studies, but the differences were not clinically or statistically significant (range, 0.4-2.2 points; 95% confidence interval, -0.19, 4.68 points). Double-row repairs had better radiographic results, but the differences were also not statistically significant (P = 0.13). Two studies had adequate power to detect a 10-point difference between repair methods using the Constant score, and 1 study had power to detect a 5-point difference using the UCLA (University of California, Los Angeles) score. Double-row rotator cuff repair does not show a statistically significant improvement in clinical outcome or radiographic healing with short-term follow-up.

  11. Practical stress analysis in engineering design

    CERN Document Server

    Huston, Ronald

    2008-01-01

    Presents the application of engineering design and analysis based on the approach of understanding the physical characteristics of a given problem and then modeling the important aspects of the physical system. This book covers such topics as contact stress analysis, singularity functions, gear stresses, fasteners, shafts, and shaft stresses.

  12. Rotors stress analysis and design

    CERN Document Server

    Vullo, Vincenzo

    2013-01-01

    Stress and strain analysis of rotors subjected to surface and body loads, as well as to thermal loads deriving from temperature variation along the radius, constitutes a classic subject of machine design. Nevertheless attention is limited to rotor profiles for which governing equations are solvable in closed form. Furthermore very few actual engineering issues may relate to structures for which stress and strain analysis in the linear elastic field and, even more, under non-linear conditions (i.e. plastic or viscoelastic conditions) produces equations to be solved in closed form. Moreover, when a product is still in its design stage, an analytical formulation with closed-form solution is of course simpler and more versatile than numerical methods, and it allows to quickly define a general configuration, which may then be fine-tuned using such numerical methods. In this view, all subjects are based on analytical-methodological approach, and some new solutions in closed form are presented. The analytical formul...

  13. Radiographical analysis concernig the etiology of degenerative spondylolisthesis of the lumbar spine

    International Nuclear Information System (INIS)

    Ihara, Koichiro

    1989-01-01

    The purpose of this article is to evaluate radiographically degenerative spondylolisthesis of the lumbar spine, with the main focus on the configuration of posterior elements. A comparative study between 49 cases of degenerative spondylolisthesis and 99 cases of other lumbar disorders was performed, using 13 radiographical parameters. The results clearly indicate the posterior elements of degenerative spondylolisthesis shifted horizontally and sagittally to allow slipping. This was due to the weak bony hook mechanism. Furthermore, almost all facet joints were morphologically classified as sagittal or intermediate type. Another meaningful difference was the alignment of the lumbar spine which showed an increase in both lordosis and lumbosacral angle. On the other hand, the level of Jacoby's line was almost the same in both groups. These characteristic configurations could be the cause of listhesis, although further study should be carried out to elucidate whether they are present at the non-listhetic stage. (author)

  14. Radiographical analysis concernig the etiology of degenerative spondylolisthesis of the lumbar spine

    Energy Technology Data Exchange (ETDEWEB)

    Ihara, Koichiro [Yamaguchi Univ., Ube (Japan). School of Medicine

    1989-12-01

    The purpose of this article is to evaluate radiographically degenerative spondylolisthesis of the lumbar spine, with the main focus on the configuration of posterior elements. A comparative study between 49 cases of degenerative spondylolisthesis and 99 cases of other lumbar disorders was performed, using 13 radiographical parameters. The results clearly indicate the posterior elements of degenerative spondylolisthesis shifted horizontally and sagittally to allow slipping. This was due to the weak bony hook mechanism. Furthermore, almost all facet joints were morphologically classified as sagittal or intermediate type. Another meaningful difference was the alignment of the lumbar spine which showed an increase in both lordosis and lumbosacral angle. On the other hand, the level of Jacoby's line was almost the same in both groups. These characteristic configurations could be the cause of listhesis, although further study should be carried out to elucidate whether they are present at the non-listhetic stage. (author).

  15. Radiographical analysis concernig the etiology of degenerative spondylolisthesis of the lumbar spine

    Energy Technology Data Exchange (ETDEWEB)

    Ihara, Koichiro (Yamaguchi Univ., Ube (Japan). School of Medicine)

    1989-12-01

    The purpose of this article is to evaluate radiographically degenerative spondylolisthesis of the lumbar spine, with the main focus on the configuration of posterior elements. A comparative study between 49 cases of degenerative spondylolisthesis and 99 cases of other lumbar disorders was performed, using 13 radiographical parameters. The results clearly indicate the posterior elements of degenerative spondylolisthesis shifted horizontally and sagittally to allow slipping. This was due to the weak bony hook mechanism. Furthermore, almost all facet joints were morphologically classified as sagittal or intermediate type. Another meaningful difference was the alignment of the lumbar spine which showed an increase in both lordosis and lumbosacral angle. On the other hand, the level of Jacoby's line was almost the same in both groups. These characteristic configurations could be the cause of listhesis, although further study should be carried out to elucidate whether they are present at the non-listhetic stage. (author).

  16. Analysis of several ways to minimize the scatter contribution in radiographic digital images of offshore pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Edmilson M.; Silva, Ademir X.; Lopes, Ricardo T., E-mail: emonteiro@nuclear.ufrj.b, E-mail: ademir@nuclear.ufrj.b, E-mail: Ricardo@lin.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Correa, Samanda C.A., E-mail: scorrea@cnen.gov.b [Comissao Nacional de Energia Nuclear (DIAPI/CGMI/CNEN), Rio de Janeiro, RJ (Brazil). Coordenacao Geral de Instalacoes Medicas e Industriais. Div. de Aplicacoes Industriais

    2011-07-01

    The aim of this work is to evaluate, through MCNPX simulations, several ways to minimize the scatter contribution in radiographic digital images of offshore pipelines. The influence of liquid inside the pipes and water surrounded the pipelines in the scatter contribution will be analyzed. The use of lead screen behind the detector to reduce the backscattered radiation and filter between the radiation source and the pipes will be discussed. (author)

  17. Analysis of several ways to minimize the scatter contribution in radiographic digital images of offshore pipelines

    International Nuclear Information System (INIS)

    Souza, Edmilson M.; Silva, Ademir X.; Lopes, Ricardo T.; Correa, Samanda C.A.

    2011-01-01

    The aim of this work is to evaluate, through MCNPX simulations, several ways to minimize the scatter contribution in radiographic digital images of offshore pipelines. The influence of liquid inside the pipes and water surrounded the pipelines in the scatter contribution will be analyzed. The use of lead screen behind the detector to reduce the backscattered radiation and filter between the radiation source and the pipes will be discussed. (author)

  18. Chest radiographic findings of scrub typhus: an analysis of 160 cases occurred in Ulsan area

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ok Hwa; Oh, Dong Heon; Kim, Ki Sung; Woo, Je Ho; Kwon, Jung Hyeok [Dong Kang General Hospital, Ulsan (Korea, Republic of)

    1993-03-15

    Scrub typhus (Tsutsugamushi disease) is an acute febrile systemic illness caused by Rickettsia Tsutsugamushi that is transmitted to humans by the bite of larval-stage trombiculid mites (chiggers). The authors analyzed chest radiographic findings of scrub typhus in 160 patients in Ulsan area. One hundred and eight (67.5%) of 160 patients showed abnormal findings which included lung lesions in 108 patients (67.5%), cardiomegaly in 37 patients (23.1%), lymphadenopathy in 25 patients (15.6%) and pleural effusion in 11 patients (6.9%). Among the lung lesions, interstitial patterns were seen in 107 patients (66.9%), mostly fine or medium reticulonodular, and air-space patterns in 14 patients (8.8%) and combined interstitial and air-space patterns in 13 patients (8.1%). Sixty-four patients (40%) had combined chest radiographic findings. The typical chest radiographic findings of scrub typhus would be helpful in evaluation of the causes of acute febrile illness that occur during late fall in the endemic area.

  19. Chest radiographic findings of scrub typhus: an analysis of 160 cases occurred in Ulsan area

    International Nuclear Information System (INIS)

    Kim, Ok Hwa; Oh, Dong Heon; Kim, Ki Sung; Woo, Je Ho; Kwon, Jung Hyeok

    1993-01-01

    Scrub typhus (Tsutsugamushi disease) is an acute febrile systemic illness caused by Rickettsia Tsutsugamushi that is transmitted to humans by the bite of larval-stage trombiculid mites (chiggers). The authors analyzed chest radiographic findings of scrub typhus in 160 patients in Ulsan area. One hundred and eight (67.5%) of 160 patients showed abnormal findings which included lung lesions in 108 patients (67.5%), cardiomegaly in 37 patients (23.1%), lymphadenopathy in 25 patients (15.6%) and pleural effusion in 11 patients (6.9%). Among the lung lesions, interstitial patterns were seen in 107 patients (66.9%), mostly fine or medium reticulonodular, and air-space patterns in 14 patients (8.8%) and combined interstitial and air-space patterns in 13 patients (8.1%). Sixty-four patients (40%) had combined chest radiographic findings. The typical chest radiographic findings of scrub typhus would be helpful in evaluation of the causes of acute febrile illness that occur during late fall in the endemic area

  20. An investigation into work related stressors on diagnostic radiographers in a local district hospital

    International Nuclear Information System (INIS)

    Verrier, William; Harvey, Jane

    2010-01-01

    Extensive research on the effects of work related stress amongst healthcare professions and the NHS has been undertaken. However, very little is known about the incidence of stress amongst UK radiographers although the few studies which have been conducted indicate that the prevalence and impact of stress on radiographers are considerable. The purpose of this study was to examine work related stressors which affect diagnostic radiographers in the imaging department of a local district hospital. The study utilised the HSE Indicator and Analysis Tools for Work Related Stress. These tools are based upon the HSE Management Standards for Work Related Stress which identifies six areas that represent potential stress hazards if managed inadequately. Two free response questions and a comments box were appended to the Indicator Tool to gain further insights into the radiographers' experiences of work related stress. The results of the study indicated that the hazards associated with work related stress risk were not being optimally managed in the department. Areas of Managers' Support, Relationships, Role and Change represented the greatest risks. In addition, the radiographers cited staff shortages, heavy workload and volume of patients as the greatest sources of pressure at work and their most common recommendations to reduce stress at work were increased staffing, improved communication and more effective feedback systems.

  1. Radiographic evaluation and statistical analysis of canine skull form: Dolichocephaly, mesocephaly and brachycephaly

    International Nuclear Information System (INIS)

    Regodon, S.; Robina, A.; Franco, A.; Vivo, J.M.; Lignereux, Y.

    1991-01-01

    Cranio-encephalic morphology of three breeds of dogs (Greyhound, Pointer and Pekinese at the rate of 10 subjects, 5 males and 5 females, in each one) has been radiologically observed. Radiographic negatives in dorso-ventral and latero-lateral positions were taken and analyzed before and after the visualisation of the encephalic cavity using baryum sulfat. 18 cranio-encephalic measurements were chosen and interpreted statistically. The results showed that certain variables were more closely correlated with morphologic types of the cranium than others. We discuss the validity of the data applied for clinical diagnostic or osteo-archeology determinations

  2. Persistent axial neck pain after cervical disc arthroplasty: a radiographic analysis.

    Science.gov (United States)

    Wagner, Scott C; Formby, Peter M; Kang, Daniel G; Van Blarcum, Gregory S; Cody, John P; Tracey, Robert W; Lehman, Ronald A

    2016-07-01

    There is very little literature examining optimal radiographic parameters for placement of cervical disc arthroplasty (CDA), nor is there substantial evidence evaluating the relationship between persistent postoperative neck pain and radiographic outcomes. We set out to perform a single-center evaluation of the radiographic outcomes, including associated complications, of CDA. This is a retrospective review. Two hundred eighty-five consecutive patients undergoing CDA were included in the review. The outcome measures were radiological parameters (preoperative facet arthrosis, disc height, CDA placement in sagittal and coronal planes, heterotopic ossification [HO] formation, etc.) and patient outcomes (persistent pain, recurrent pain, new-onset pain, etc.). We performed a retrospective review of all patients from a single military tertiary medical center from August 2008 to August 2012 undergoing CDA. Preoperative, immediate postoperative, and final follow-up films were evaluated. The clinical outcomes and complications associated with the procedure were also examined. The average radiographic follow-up was 13.5 months and the rate of persistent axial neck pain was 17.2%. For patients with persistent neck pain, the rate of HO formation per level studied was 22.6%, whereas the rate was significantly lower for patients without neck pain (11.7%, p=.03). There was no significant association between the severity of HO and the presence of neck pain. Patients with a preoperative diagnosis of cervicalgia, compared to those without cervicalgia, were significantly more likely to experience continued neck pain postoperatively (28.6% vs. 13.1%, p=.01). There were no differences in preoperative facet arthrosis, pre- or postoperative disc height, segmental range of motion, or placement of the device relative to the posterior edge of the vertebral body.However, patients with implants more centered between the uncovertebral joints were more likely to experience posterior neck pain

  3. Residual stress analysis in thick uranium films

    International Nuclear Information System (INIS)

    Hodge, A.M.; Foreman, R.J.; Gallegos, G.F.

    2005-01-01

    Residual stress analysis was performed on thick, 1-25 μm, depleted uranium (DU) films deposited on an Al substrate by magnetron sputtering. Two distinct characterization techniques were used to measure substrate curvature before and after deposition. Stress evaluation was performed using the Benabdi/Roche equation, which is based on beam theory of a bi-layer material. The residual stress evolution was studied as a function of coating thickness and applied negative bias voltage (0, -200, -300 V). The stresses developed were always compressive; however, increasing the coating thickness and applying a bias voltage presented a trend towards more tensile stresses and thus an overall reduction of residual stresses

  4. Fractal dimension analysis in digital periapical radiographs: A diagnostic indicator of osteoporosis in post-menopausal women

    Directory of Open Access Journals (Sweden)

    Mathivanan Kavitha

    2017-01-01

    Full Text Available Objectives: To assess the alveolar bone density by fractal dimension (FD analysis in radiovisiograph of postmenopausal women of mandibular posterior region and to correlate FD values with t-scores of quantitative ultrasound of the calcaneus bone. Materials and Methods: This study, approved by the institutional review board, included 40 participants, aged 45–60 years divided into two groups. Twenty postmenopausal women with osteoporosis comprised group 1, and 20 postmenopausal women without osteoporosis comprised group 2 based on bone mineral density assessment of ultrasound of the calcaneus bone. Digital dental radiograph of mandibular first molar were obtained and used for assessing alveolar bone density by FD analysis and were correlated with t-scores of ultrasound of calcaneus bone. Results: The mean FD values were evaluated using SPSS 14 version software, and were found to be 1.738 and 1.867 for group 1 and group 2, respectively, which was statistically significant (P 0.05. Conclusion: FD analysis using direct digital periapical radiographs is a novel method, which can be used for early diagnosis of osteoporosis in the alveolar bone.

  5. Stress analysis of shear/compression test

    International Nuclear Information System (INIS)

    Nishijima, S.; Okada, T.; Ueno, S.

    1997-01-01

    Stress analysis has been made on the glass fiber reinforced plastics (GFRP) subjected to the combined shear and compression stresses by means of finite element method. The two types of experimental set up were analyzed, that is parallel and series method where the specimen were compressed by tilted jigs which enable to apply the combined stresses, to the specimen. Modified Tsai-Hill criterion was employed to judge the failure under the combined stresses that is the shear strength under the compressive stress. The different failure envelopes were obtained between the two set ups. In the parallel system the shear strength once increased with compressive stress then decreased. On the contrary in the series system the shear strength decreased monotonicly with compressive stress. The difference is caused by the different stress distribution due to the different constraint conditions. The basic parameters which control the failure under the combined stresses will be discussed

  6. Radiographic element

    International Nuclear Information System (INIS)

    Abbott, T.I.; Jones, C.G.

    1984-01-01

    Radiographic elements are disclosed comprised of first and second silver halide emulsion layers separated by an interposed support capable of transmitting radiation to which the second image portion is responsive. At least the first imaging portion contains a silver halide emulsion in which thin tubular silver halide grains of intermediate aspect ratios (from 5:1 to 8:1) are present. Spectral sensitizing dye is adsorbed to the surface of the tubular grains. Increased photographic speeds can be realized at comparable levels of crossover. (author)

  7. Comparative analysis of intraoral radiographs with variation of tube angulation to detect insufficient crown margins.

    Science.gov (United States)

    Sailer, Benjamin F; Geibel, Margrit-Ann

    2013-01-01

    Variations in angulation of the x-ray tube affect the appearance of insufficient approximal crown margins on intraoral radiographs. This study examines the impact of such angular variation on the assessment of digital radiographs using three different X-ray tubes--Heliodent DS (Sirona), Gendex Expert DC (KaVo Dental) and Focus (KaVo Dental)--as well as the Gendex Visualix eHD CCD sensor (KaVo Dental). The test specimens, crowned teeth 46 from two mandibles provided by the Institute of Anatomy and Cell Biology, were examined with each tube. The results indicate great differences in the angles indicative of insufficient crown margins on X-ray images. Because of beam divergence and the crown marginal gap, the length and width of which frequently varies, it is difficult to infer any optimum angle from the data. This leads to the conclusion that at present, it is not possible to establish ideal angles for visualization of insufficient approximal crown margins.

  8. Pattern analysis of planning and management at the radiographic dept. in hospital

    International Nuclear Information System (INIS)

    Yanagisawa, Makoto; Taniguchi, Gen; Imai, Shoji.

    1980-01-01

    We made 'typical working models' from the survey of 3 hospitals. The models can express staffs' movements that are variable as management types. We adapted these models to some planning types those are made from typical layouts, and evaluated the planning types of the radiographic dept. in hospital. The result of evaluation are as follows. (1) A-1, B-1 type; the contacts between staffs and patients are done well, but that is difficult to keep sterilized materials clean. These types are useful to the specific treatment zones. (2) B-3 type; this planning type is designed for staffs' movements of each room to be independent from other. This aim is well reflected in the result. But we must point out that so to speak assistant staffs', porters' or messengers' works are very hard. (3) C-1, D-1 type; staffs' zone and patients' are clearly separated in these types. So the staffs hardly pass through radiographic rooms to contact with patients. (4) D-2 type; this type, improved from B-1 type, is not seen in hospitals as ever. But this type can adopt almost any management type and be evaluated well in the result. (author)

  9. Radiographic analysis of the temporomandibular joint by the standardized projection technique

    International Nuclear Information System (INIS)

    Choe, Han Up; Park, Tae Won

    1983-01-01

    The purpose of this study was to investigate the radiographic images of the condylar head in clinically normal subjects and the TMJ patients using standardized projection technique. 45 subjects who have not clinical evidence of TMJ problems and 96 patients who have the clinical evidence of TMJ problems were evaluated, but the patients who had fracture, trauma and tumor on TMJ area were discluded in this study. For the evaluation of radiographic images, the author has observed the condylar head positions in closed mouth and 2.54 cm open mouth position taken by the standardized transcranial oblique lateral projection technique. The results were as follow: 1. In closed mouth position, the crest of condylar head took relatively posterior position to the deepest point of the glenoid fossa in 8.9% of the normals and in 26.6% of TMJ patients. 2. In 2.54 cm open mouth position, condylar head took relatively posterior position to the articular eminence in 2 .2% of TMJ patients and 39.6% of the normals. 3. In open mouth position, the horizontal distance from the deepest point of the glenoid fossa to the condylar head was 13.96 mm in the normals and 10.68 mm in TMJ patients. 4. The distance of true movement of condylar head was 13.49 mm in the normals and 10.27 mm in TMJ patients. 5. The deviation of mandible in TMJ patients was slightly greater than of the normals.

  10. Long-term outcomes of dental implants placed in elderly patients: a retrospective clinical and radiographic analysis.

    Science.gov (United States)

    Park, Jung-Chul; Baek, Won-Sun; Choi, Seong-Ho; Cho, Kyoo-Sung; Jung, Ui-Won

    2017-02-01

    The aim of this retrospective study was to determine the clinical and the radiographic outcomes of dental implants placed in elderly people older than 65 years. In total, 902 implants in 346 patients (age: 65-89 years) were followed up for 2-17 years following the implant surgery. The survival rate of these implants was recorded and analyzed. Changes in marginal bone levels were also analyzed in serial radiographs, and Cox regression analysis for implant loss was performed. The survival rates were 95.39% and 99.98% in the implant- and patient-based analyses, respectively (involving a total of 29 implant failures), and the marginal bone loss at the implants was 0.17 ± 0.71 mm (mean ± SD). The number of failures was greatest in patients aged 65-69 years. The Cox regression with shared frailty analysis showed that implant loss was significantly greater in those aged 65-69 years than in those aged 70-74 years (P implant systems. Within the limitations of this retrospective study, it was concluded that implant therapy can be successfully provided to elderly patients and that age alone does not seem to affect the implant survival rate. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Stress analysis in FRP composites

    Directory of Open Access Journals (Sweden)

    Nitin Jauhari

    2016-09-01

    Full Text Available A composite material, in mechanics sense, is a structure with the ingredients as element transferring forces to adjacent members. The issue of defects and their effect on the mechanical properties of composites is of great concern among high end users. Experimental investigation of failure modes of composite materials requires correlating the fundamentals of composite materials, their mechanical properties as well as their failure characteristics in the presence of defects. In this paper, three formats of defects of hole (single, double and quadruple as a discontinuity were incorporated along with tensile testing. Unique failure modes of these specimens provided overview regarding mechanical behaviour of composite materials containing defects. Certain correlations were observed between defects and resulting properties. Results are in agreement with general behaviour of FRP composite laminates and it can be concluded that for low deformation in composite laminates, number of layers must be increased, which at the same time results in increase of von-Mises stress. Fibres are the main constituents which are responsible for strength of a composite laminate and they along with fibre orientation, play an important role on its load bearing capacity. It can be inferred based on the analysis that cross-ply configuration [0°/90°] has good load bearing capacity as well as least deflection emphasizing more strength.

  12. Nuclear class 1 piping stress analysis

    International Nuclear Information System (INIS)

    Lucas, J.C.R.; Maneschy, J.E.; Mariano, L.A.; Tamura, M.

    1981-01-01

    A nuclear class 1 piping stress analysis, according to the ASME code, is presented. The TRHEAT computer code has been used to determine the piping wall thermal gradient. The Nupipe computer code was employed for the piping stress analysis. Computer results were compared with the allowable criteria from the ASME code. (Author) [pt

  13. Pattern analysis of planning and management at the radiographic dept. in hospital

    International Nuclear Information System (INIS)

    Yanagisawa, Makoto; Taniguchi, Gen; Imai, Shoji.

    1979-01-01

    This papers attempt to make the planning method, and the relationships between planning and management by the circulation studies. We investigated the circulation of radiographic departments in 3 hospitals, the managements of 20 hospitals, and the planning layouts of 63 hospitals. Now we made 9 typical diagrammatic layouts to classify many plans and some patterns to classify many management types. In this process we used some items to classify as follows. (1) Staffs' works; there are diagnosis, photographing, nursing, developing, assistant or management works, and so on. (2) Management manners; there are three types, such as only photographing facility type, photographing and nursing facility type, and diagnosis facility type. (3) Classify how to developing and how to do assistant or management works. (4) Planning types; table-6 1) Patients' spaces are separate or not. 2) Photographing staffs' corners are independent or not. 3) Developing spaces are centralized or not. 4) Are there or not, the connections between patients' zones and staffs'. (author)

  14. Flaw acceptance criteria taking into consideration the NDT: radiographic and ultrasonic testing. Analysis through the fracture mechanics methods

    International Nuclear Information System (INIS)

    Capurro, E.; Alicino, F.; Corvi, A.

    1993-01-01

    The present study compares and evaluates the flaw acceptance criteria of the non-destructive inspections meeting European Community standards, through the application of the fracture mechanics methods that were determined and verified by the previous activity. Some choices were made; these, however, do not change the general validity of the conclusions. Shaved full-penetration butt welds of Class 1 components making up the primary circuit were considered and the following parameters varied: standards: French, German, Italian (ASME III) and UK; material: AISI 316 and low alloy steel A 533; base material and weld metal; temperature: RT, 370 deg C for the austenitic and 260 deg C for the ferritic steel; ultrasonic and radiographic methods; defect position: surface and internal; stress condition: situations with different primary and secondary stresses. From a preliminary examination of this study it is evident that the large quantity of results available and the abundance of information contained therein make a simple and exhaustive synthesis difficult. In fact, different analyses are possible and we have, therefore, limited the research to activities to perform a comparison and a general evaluation of the acceptance criteria of the non-destructive testing. (authors). 57 refs., 25 figs., 11 tabs

  15. Digital subtraction radiographic analysis of the combination of bioabsorbable membrane and bovine morphogenetic protein pool in human periodontal infrabony defects

    Directory of Open Access Journals (Sweden)

    Maria do Carmo Machado Guimarães

    2010-08-01

    Full Text Available OBJECTIVES: This study assessed the bone density gain and its relationship with the periodontal clinical parameters in a case series of a regenerative therapy procedure. MATERIAL AND METHODS: Using a split-mouth study design, 10 pairs of infrabony defects from 15 patients were treated with a pool of bovine bone morphogenetic proteins associated with collagen membrane (test sites or collagen membrane only (control sites. The periodontal healing was clinically and radiographically monitored for six months. Standardized pre-surgical and 6-month postoperative radiographs were digitized for digital subtraction analysis, which showed relative bone density gain in both groups of 0.034 ± 0.423 and 0.105 ± 0.423 in the test and control group, respectively (p>0.05. RESULTS: As regards the area size of bone density change, the influence of the therapy was detected in 2.5 mm² in the test group and 2 mm² in the control group (p>0.05. Additionally, no correlation was observed between the favorable clinical results and the bone density gain measured by digital subtraction radiography (p>0.05. CONCLUSIONS: The findings of this study suggest that the clinical benefit of the regenerative therapy observed did not come with significant bone density gains. Long-term evaluation may lead to a different conclusions.

  16. Radiographic apparatus

    International Nuclear Information System (INIS)

    Lapidus, S.N.

    1979-01-01

    Raytheon Company, U.S.A. have patented an on-line electronic system of normalising the responses from the photomultiplier tubes used in conjunction with a scintillator in an X-ray radiographic camera. A problem with present cameras is that the individual photomultipliers have different intensity responses which also change in time with respect to each other. The individual responses of each photomultiplier tube are measured with a uniform sheet of radioactive material in front of the camera. The associated electronic equipment then calculates scaling factors which give all photomultiplier tubes an identical response and then places these factors in an addressable store. The store is then addressed in an on-line mode to produce a visual display of the transmitted X-rays. (U.K.)

  17. Radiographic apparatus

    International Nuclear Information System (INIS)

    Dalton, B.L.

    1984-01-01

    This patent application describes a radiographic apparatus including an array of radiation sensors, a source of radiation for projecting a beam through a body and means for moving one of said source and array relative to the body and for producing an electrical signal representative of the movement of the other of said source and array needed to bring the array into register with the beam. Drive means are arranged to move the other of said source and array in response to the electrical signal. In one embodiment, the source is rotated by an amount measured by a grating and associated electronics. The required movement of the array to maintain registration is calculated and transmitted to a driver. Alternatively, a laser may be mounted with the same and the array driven so that the laser beam continuously impinges on a photocell mounted with the array. (author)

  18. Analysis of variation in calibration curves for Kodak XV radiographic film using model-based parameters.

    Science.gov (United States)

    Hsu, Shu-Hui; Kulasekere, Ravi; Roberson, Peter L

    2010-08-05

    Film calibration is time-consuming work when dose accuracy is essential while working in a range of photon scatter environments. This study uses the single-target single-hit model of film response to fit the calibration curves as a function of calibration method, processor condition, field size and depth. Kodak XV film was irradiated perpendicular to the beam axis in a solid water phantom. Standard calibration films (one dose point per film) were irradiated at 90 cm source-to-surface distance (SSD) for various doses (16-128 cGy), depths (0.2, 0.5, 1.5, 5, 10 cm) and field sizes (5 × 5, 10 × 10 and 20 × 20 cm²). The 8-field calibration method (eight dose points per film) was used as a reference for each experiment, taken at 95 cm SSD and 5 cm depth. The delivered doses were measured using an Attix parallel plate chamber for improved accuracy of dose estimation in the buildup region. Three fitting methods with one to three dose points per calibration curve were investigated for the field sizes of 5 × 5, 10 × 10 and 20 × 20 cm². The inter-day variation of model parameters (background, saturation and slope) were 1.8%, 5.7%, and 7.7% (1 σ) using the 8-field method. The saturation parameter ratio of standard to 8-field curves was 1.083 ± 0.005. The slope parameter ratio of standard to 8-field curves ranged from 0.99 to 1.05, depending on field size and depth. The slope parameter ratio decreases with increasing depth below 0.5 cm for the three field sizes. It increases with increasing depths above 0.5 cm. A calibration curve with one to three dose points fitted with the model is possible with 2% accuracy in film dosimetry for various irradiation conditions. The proposed fitting methods may reduce workload while providing energy dependence correction in radiographic film dosimetry. This study is limited to radiographic XV film with a Lumisys scanner.

  19. Radiographers and trainee radiologists reporting accident radiographs

    DEFF Research Database (Denmark)

    Buskov, L; Abild, A; Christensen, A

    2013-01-01

    To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital....

  20. Radiographic analysis of odontogenic cysts showing displacement of the mandibular canal

    International Nuclear Information System (INIS)

    Cho, Bong Hae

    2003-01-01

    To assess the radiographic findings of odontogenic cysts showing displacement of the mandibular canal using computed tomographic (CT) and panoramic images. CT and panoramic images of 63 odontogenic cysts (27 dentigerous, 16 odontogenic keratocysts, and 20 radicular cysts) were analyzed to evaluate the following parameters: the dimension and shape of the cysts, and the effect of the cysts on the mandibular canal and cortical plates. Of the 63 cysts examined in the study, 35 (55.6%) showed inferior displacement of the mandibular canal and 46 (73.0%) showed perforation of the canal. There were statistically significant differenced between CT and panoramic images in depicting displacement and perforation of the mandibular canal. Cortical expansion was seen in 46 cases (73.0%) and cortical perforation in 23 cases (36.5%). The radicular cysts showed cortical expansion and perforation less frequently than the other cyst groups. Large cysts of mandible should be evaluated by multiplanar CT images in order to detect the mandibular canal and cortical bone involvement.

  1. Immobilisation-induced changes in forearm bone quantity and quality: radiographic fourier image analysis vs bone densitometry

    International Nuclear Information System (INIS)

    Moore, G.; Price, R.I.; Buck, A.M.; University of Western Australia, Nedlands, WA; Price, R.L.; University of Western Australia, Nedlands, WA; Sweetman, I.M.; Ho, S.

    1996-01-01

    Full text: Determinants of bone fracture risk include indices of bone 'quantity' such as bone mineral content (BMC, mineral mass per unit scanned bone length), plus 'environmental' (eg impact force) and 'quality' factors (Melton L.J. III et al, Bone and Min 2: 321, 1987). Bone 'quality' refers largely to the micro-geometry of bone (∼ 10-200μ), but has been less well studied because of the need for bone slices from (invasive) bone biopsies. Such studies often compare the geometry of trabecular networks (eg trabecular bone volume, trabecular number) with clinical outcomes such as fracture rates. Another (invasive) approach is to examine the two-dimensional (2-D) Fourier transform (FT) of a high-resolution radiographic image of the bone slice, since structural information is in theory encoded in the 2-D spatial-frequency (ν) spectrum. Additionally, the FT method can be applied to bone images obtained in-vivo, though superposition of information from the third dimension is a major confounding factor in their interpretation. Quantitative radiography of the ultradistal (UD) forearm permits determination of BMC (Price R et al; ACPSEM 6: 128- 137, 1983 and ACPSEM 11: 36-43, 1988), and (as a bonus) reveals a pattern (suitable for FT analysis) of the radiographic shadows of the 3-D trabecular network projected onto the image plane. Hemiplegia is associated with excessive bone loss in the paralysed (hemi) forearm, and is a model for the study of immobilisation osteoporosis. Thus, by comparing hemiplegia-induced changes in BMC and trabecular structure, derived from the same in vivo radiographic image, it is possible to compare directly the effects of disease on both bone quantity and quality, using the image of the non-paralysed (non-hemi) arm as a control. Seventy-four patients with hemiplegia of duration 3.6±3.6 (Mean±SD) years were studied cross-sectionally for radiographic BMC of their normal and paralysed UD forearms in AP view, each arm in duplicate. Methods

  2. Radiographic tales

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder

    Purpose Until now a large number of scientific studies have focused on technological aspects of radiography. This study is a step in another direction which examines the relationship between man and technology within radiography instead of considering man and technology as separate entities. Meth...... of their narrative alertness. Errors and failure to keep the time schedule can, however, lead the radiographers to a change of perspective that makes them displace man from the scene of radiography by playing on the premises of technology.......Purpose Until now a large number of scientific studies have focused on technological aspects of radiography. This study is a step in another direction which examines the relationship between man and technology within radiography instead of considering man and technology as separate entities...... a practice in which the relationship between man and technology is marked by a struggle of domination of one over the other. The struggle expresses itself through two competing plots: A diagnostic plot with a prevailing, but not merely chronological structure mostly composed of events tied to pathology...

  3. The additional value of the lateral chest radiograph for the detection of small pulmonary nodules-a ROC analysis.

    Science.gov (United States)

    Kluthke, Robin Alexander; Kickuth, Ralph; Bansmann, Paul Martin; Tüshaus, Carolin; Adams, Stephan; Liermann, Dieter; Kirchner, Johannes

    2016-11-01

    For the past 30 years, many authors have described different advantages of the use of the additional lateral chest radiograph. However, some radiologic departments gave up performing the lateral view recently. A potential reason for this might be a lack of evidence for any diagnostic benefit of the additional lateral view of the thorax in recent studies. The objective of this study was to evaluate the diagnostic benefit of the additional lateral view for the detection of small pulmonary nodules compared with CT examinations as a gold standard. The patient population consisted of 45 patients with SPN and 45 patients without SPN. Four radiologists with varying experience in the assessment of thoracic imaging first examined the sole posteroanterior (PA) projection. After a few days, they were instructed to examine the PA and the additional lateral view. A receiver-operating characteristic analysis was accomplished to compare the documented results. The mean Az value of the sole PA view was 0.75 and 0.77 by the combination of PA and additional lateral view. So, there was no significant difference between the detectable Az values (Δ = 0.02; p = 0.384). With a cut-off value of >3, the additional view even reduced the sensitivity by averaging to 5.6%. The decrease of sensitivity by using the additional view was most detectable within the group of more experienced radiologists. The additional lateral view of the chest provides no diagnostic benefit in the detection of small pulmonary nodules in comparison with the sole PA projection. Nevertheless, the results of the present study must not be understood as a general evaluation of the benefits of the lateral radiograph per se, because we did not examine other relevant issues (i.e. cardiac failure, lung parenchyma diseases or abnormalities in hilar anatomy). Advances in knowledge: Our study demonstrates a lack of evidence for any diagnostic benefit of the additional lateral view of the thorax in detecting SPN.

  4. Assessment of the willingness of radiographers in mammography to accept new responsibilities in role extension: Part one - Quantitative analysis

    Energy Technology Data Exchange (ETDEWEB)

    Moran, S., E-mail: sheila.moran@uon.edu.au [BreastScreen New South Wales, Hunter New England Program (Australia); Warren-Forward, H. [Discipline of Medical Radiation Sciences, University of Newcastle, NSW (Australia)

    2011-11-15

    Purpose: The success of skill development amongst radiographers in the UK over the last 30 years has stimulated discussion about similar developments in Australia. The introduction of flexible roles and responsibilities may well improve the recruitment and retention issues facing radiographers in mammography by increasing the level of job satisfaction and professional confidence. The main purpose of this study was to investigate the attitudes of BreastScreen Australia radiographers toward mammography screen reading and to determine other areas of interest in role extension. Methods and materials: Questionnaires were sent to radiographers working within Australian BreastScreening programs. The emphasis for this study was on image interpretation, although different areas of role expansion were discussed. The radiographers were asked whether there were any barriers preventing them from becoming screen readers and the levels of supervision and training they thought appropriate for different tasks.They were asked to discuss possible benefits and disadvantages of additional responsibilities. The involvement of radiographers with routine screening was explored as well as the possibility of further training leading to more diversity in their careers. Results: The results highlight the interest that radiographers working in Australia have for role extension in mammography. The radiographers indicated they would feel reasonably confident to undertake image interpretation, but two areas gave them cause for concern - a lack of prior images, and the prospect of no radiologist reading with them. The majority (79%) of radiographers were prepared to undertake extra training and demonstrated that the importance of increased pay for these extra responsibilities (39%) lagged behind the importance of increased professional equity (47%) and increased enjoyment and interest in mammography (66%). The possibility of role expansion being a cause of division in the workforce (pressure to

  5. Assessment of the willingness of radiographers in mammography to accept new responsibilities in role extension: Part one - Quantitative analysis

    International Nuclear Information System (INIS)

    Moran, S.; Warren-Forward, H.

    2011-01-01

    Purpose: The success of skill development amongst radiographers in the UK over the last 30 years has stimulated discussion about similar developments in Australia. The introduction of flexible roles and responsibilities may well improve the recruitment and retention issues facing radiographers in mammography by increasing the level of job satisfaction and professional confidence. The main purpose of this study was to investigate the attitudes of BreastScreen Australia radiographers toward mammography screen reading and to determine other areas of interest in role extension. Methods and materials: Questionnaires were sent to radiographers working within Australian BreastScreening programs. The emphasis for this study was on image interpretation, although different areas of role expansion were discussed. The radiographers were asked whether there were any barriers preventing them from becoming screen readers and the levels of supervision and training they thought appropriate for different tasks.They were asked to discuss possible benefits and disadvantages of additional responsibilities. The involvement of radiographers with routine screening was explored as well as the possibility of further training leading to more diversity in their careers. Results: The results highlight the interest that radiographers working in Australia have for role extension in mammography. The radiographers indicated they would feel reasonably confident to undertake image interpretation, but two areas gave them cause for concern - a lack of prior images, and the prospect of no radiologist reading with them. The majority (79%) of radiographers were prepared to undertake extra training and demonstrated that the importance of increased pay for these extra responsibilities (39%) lagged behind the importance of increased professional equity (47%) and increased enjoyment and interest in mammography (66%). The possibility of role expansion being a cause of division in the workforce (pressure to

  6. Radiographic cephalometry analysis of head posture and craniofacial morphology in oral breathing children

    Directory of Open Access Journals (Sweden)

    Vukićević Vladanka

    2017-01-01

    Full Text Available Background/Aim. Nasal breathing plays an important role in overall physical growth and mental development, as well as in the growth of the craniofacial complex. Oral breathing over a long period of time, can cause changes in position of the head relative to the cervical spine and jaw relationship. It can cause an open bite and the narrowness of the maxillary arch due to increased pressure of strained face. The aim of this study was to analyze the position of the head and craniofacial morphology in oral breathing children, and compare the values obtained compared with those of the same parameters in nasal brething children. Methods. We analyzed the profile cephalometric radiographs of 60 patients who had various orthodontic problems. In the first group there were 30 patients aged 8–14 years, in which oral breathing is confirmed by clinical examination. In the second group there were 30 patients of the same age who had orthodontic problems, but did not show clinical signs of oral breathing. The analyses covered the following: craniocervical angle (NS/OPT, the length of the anterior cranial base (NS, anterior facial height (N-Me, posterior facial height (S-Go, the angle of maxillary prognathism (SNA, angle of mandibular prognathism (SNB, difference between angles SNA and SNB (ANB angle, the angle of the basal planes of the jaws (SpP/MP, cranial base angle (NSB, and the angle of facial convexity (NA/Apg. Results. The average value of the craniocervical angle (NS/OPT was significantly higher in OB children (p = 0.004. There were significantly different values of SNA (p < 0.001, ANB (p < 0.001, NA/APg (p < 0.001 and length of the anterior cranial base (NS (p = 0.024 between groups. Conclusion. Oral breathing children have pronounced retroflexion of the head in relation to the cervical spine compared to nasal breathing children, and the most prominent characteristics of the craniofacial morphology of skeletal jaw relationship of class II and

  7. Modeling dental radiographic systems

    International Nuclear Information System (INIS)

    Webber, R.L.

    1980-01-01

    The Bureau of Radiological Health has been actively collaborating with the Clinical Investigations Branch, NIDR, in applied research involving diagnostic use of ionizing radiation in dentistry. This work has centered on the search for alternatives to conventional radiographic systems in an attempt to improve diagnostic performance while reducing the required exposure. The basic approach involves analysis of factors limiting performance of properly defined diagnostic tasks and the modeling alternative systems with an eye toward increasing objective measures of performance. Previous collaborative work involved using a nonlinear model to compare various x-ray spectra. The data were expressed as brightness-contrast versus exposure for simulated tasks of clinical interest. This report supplements these findings by extending the number of parameters under investigation and modifying the mode of data display so that an actual radiographic image can be simulated on a television screen

  8. Radiographic testing of wood

    International Nuclear Information System (INIS)

    Osterloh, K.; Zscherpel, U.; Raedel, C.; Weidemann, G.; Meinel, D.; Goebbels, J.; Ewert, U.; Hasenstab, A.; Buecherl, T.

    2007-01-01

    Wood is an old and established consumption and construction material. It is still the most common material for constructing furniture, roofs, playgrounds and mine supports. In contrast to steel and concrete, wood warns of extreme loads by creaking. Its mechanical stability is more influenced by decay than by peripheral cracks. While external cracks are visible, internal decay by fungus growth is undetectable from outside. This may be a safety problem in supporting structures. The best analysis of the internal structure is provided by computed tomography, but this is also the most complex method, much more so than simple radiographic testing. However, the latter is made inaccurate by scattered radiation resulting from internal moisture. With the image processing options of digital radiographic techniques, the structural information can be separated effectively from noise. In contrast to X-ray and gamma radiography, neutron radiography provides information on the spatial distribution of moisture. In healthy wood, water is conducted in the sapwood while the hardwood is dry. Moisture in hardwood is caused by infestations, e.g. fungus growth. The contribution presents a comparative analysis of the available radiographic methods. (orig.)

  9. Residual stress concerns in containment analysis

    International Nuclear Information System (INIS)

    Costantini, F.; Kulak, R. F.; Pfeiffer, P. A.

    1997-01-01

    The manufacturing of steel containment vessels starts with the forming of flat plates into curved plates. A steel containment structure is made by welding individual plates together to form the sections that make up the complex shaped vessels. The metal forming and welding process leaves residual stresses in the vessel walls. Generally, the effect of metal forming residual stresses can be reduced or virtually eliminated by thermally stress relieving the vesseL In large containment vessels this may not be practical and thus the residual stresses due to manufacturing may become important. The residual stresses could possibly tiect the response of the vessel to internal pressurization. When the level of residual stresses is significant it will affect the vessel's response, for instance the yielding pressure and possibly the failure pressure. The paper will address the effect of metal forming residual stresses on the response of a generic pressure vessel to internal pressurization. A scoping analysis investigated the effect of residual forming stresses on the response of an internally pressurized vessel. A simple model was developed to gain understanding of the mechanics of the problem. Residual stresses due to the welding process were not considered in this investigation

  10. Concept Analysis: Alzheimer’s Caregiver Stress

    Science.gov (United States)

    Llanque, Sarah; Savage, Lynette; Rosenburg, Neal; Honor’s, BA; Caserta, Michael

    2015-01-01

    AIM The aim of this article was to analyze the concept of caregiver stress in the context of caring for a person with Alzheimer’s disease and related dementias. BACKGROUND Currently, there are more than 15 million unpaid care-givers for persons suffering from Alzheimer’s disease and related dementias. This unpaid care can be stressful for caregivers due to the chronic nature of the disease process, as well as other factors. METHOD The paper incorporates the modified method of Wilson’s concept analysis procedure to analyze the concept of caregiver stress. DATA SOURCES A review of the literature was undertaken using the Cumulative Index to Nursing and Allied Health Literature, Google Scholar, and PubMed. RESULTS A theoretical definition of caregiver stress is provided, and the defining attributes, related concepts, antecedents, and consequences of caregiver stress are proposed, and case studies are presented. CONCLUSIONS The analysis demonstrates that caregiver stress is the unequal exchange of assistance among people who stand in close relationship to one another, which results in emotional and physical stress on the caregiver. Implications for future nursing research and practice conclude the paper. PMID:24787468

  11. Stress analysis for robot arm version 2

    International Nuclear Information System (INIS)

    Anwar Abdul Rahman; Fikri, A.; Salleh, M. S.; Mohd Arif Hamzah; Azraf Azman; Rosli Darmawan; Mohd Rizal Mamat

    2010-01-01

    The design of a robot needs to be analyzed to ensure the specification and requirement by the user is full filled. Therefore, stress analysis has been performed on the robot arm version 2 after its complete fabrication. This paper discusses the result of the analysis and proposed measures to improve the future design of robot arm. (author)

  12. Implications of stress range for inelastic analysis

    International Nuclear Information System (INIS)

    Karabin, M.E.; Dhalla, A.K.

    1981-01-01

    The elastic stress range over a complete load cycle is routinely used to formulate simplified rules regarding the inelastic behavior of structures operating at elevated temperature. For example, a 300 series stainless steel structure operating at elevated temperature, in all probability, would satisfy the ASME Boiler and Pressure Vessel Code criteria if the linearized elastic stress range is less than three times the material yield strength. However, at higher elastic stress ranges it is difficult to judge, a priori, that a structural component would comply with inelastic Code criteria after a detailed inelastic analysis. The purpose of this paper is to illustrate that it is not the elastic stress range but the stress intensities at specific times during a thermal transient which provide a better insight into the inelastic response of the structure. The specific example of the CRBRP flued head design demonstrates that the temperature differential between various parts of the structure can be changed by modifying the insulation pattern and heat flow path in the structure, without significantly altering the elastic stress range over a complete load cycle. However, the modified design did reduce the stress intensity during steady state elevated temperature operation. This modified design satisfied the inelastic Code criteria whereas the initial design failed to comply with the strain accumulation criterion

  13. Stress analysis of PCV nozzle junction

    International Nuclear Information System (INIS)

    Uchiyama, Shoichi; Oikawa, Tsuneo; Hoshino, Seizo

    1976-01-01

    Most of various pressure vessels comprise each one cylindrical shell and one or more nozzles. In this study, in order to analyze the stress in the structures of this type as minutely and exactly as possible, the program for stress analysis by the finite element method was made, which is required for the strength analysis for three-dimensional structures. Especially, the problem of the stress distribution around nozzle junctions was solved theoretically with the program. The program for the analysis developed in this study is provided with various functions, such as the input generator for cylindrical, conical and spherical shells, and plotter, and is very covenient. The accuracy of analysis is very good. The method of analysis and the calculation of the rigidity matrices for the deformation in plane and bending are explained. The result of the stress analysis around the nozzle junctions of a containment vessel with this program was in good agreement with experimental data and the result with SAP-4 code, therefore the propriety of the calculated result with this program was proved. Also calculations were carried out on three cases, namely a flat plate fixed at one end with distributed load, a cylinder fixed at one end with internal pressure, and an I-beam fixed at one end with concentrated load. The calculated results agreed well with theoretical solutions in all cases. (Kako, I.)

  14. Morphometric analysis of three normal facial types in mixed dentition using posteroanterior cephalometric radiographs: preliminary results

    Directory of Open Access Journals (Sweden)

    Renato Bigliazzi

    2017-08-01

    Full Text Available The aim of the present investigation was to evaluate the craniofacial features of subjects with normal occlusion with different vertical patterns in the mixed dentition using morphometric analysis (Thin-Plate Spline analysis - TPS applied to posteroanterior (PA films. The sample comprised 39 individuals (18 females and 21 males, all in mixed dentition, aged from 8.4 to 10 years with satisfactory occlusion and balanced profile and with no history of orthodontic or facial orthopedic treatment. The sample was divided into three groups (mesofacial, brachyfacial and dolichofacial according to the facial types proposed by Ricketts (1989. The average craniofacial configurations of each study group were obtained by orthogonal superimposition of Procrustes, thereby eliminating size differences and allowing only shape differences between groups to be analyzed by viewing the TPS deformation grid. Significant differences were found among the three facial types but were more remarkable between mesofacials and dolichofacials than between mesofacials and brachyfacials. TPS morphometric analysis proved efficient for accurate visualization of transverse and vertical differences among facial types even before pubertal growth spurt. These differences cannot be easily detected by traditional posteroanterior cephalometry.

  15. Plant stress analysis technology deployment

    Energy Technology Data Exchange (ETDEWEB)

    Ebadian, M.A.

    1998-01-01

    Monitoring vegetation is an active area of laser-induced fluorescence imaging (LIFI) research. The Hemispheric Center for Environmental Technology (HCET) at Florida International University (FIU) is assisting in the transfer of the LIFI technology to the agricultural private sector through a market survey. The market survey will help identify the key eco-agricultural issues of the nations that could benefit from the use of sensor technologies developed by the Office of Science and Technology (OST). The principal region of interest is the Western Hemisphere, particularly, the rapidly growing countries of Latin America and the Caribbean. The analysis of needs will assure that the focus of present and future research will center on economically important issues facing both hemispheres. The application of the technology will be useful to the agriculture industry for airborne crop analysis as well as in the detection and characterization of contaminated sites by monitoring vegetation. LIFI airborne and close-proximity systems will be evaluated as stand-alone technologies and additions to existing sensor technologies that have been used to monitor crops in the field and in storage.

  16. Fetal MR Imaging Analysis of Sirenomelia with Clinico Radiographic Correlation: A Case Report.

    Science.gov (United States)

    Nori, Madhavi; Prasad, Raghavendra G; Reddy, Arvind K; Cheguri, Sandeep Reddy

    2016-06-01

    Sirenomelia is a social curiosity, a medical and diagnostic challenge prenatally compounded by varied diagnostic difficulties. Prenatal diagnosis of sirenomelia was and continues to be a challenge although von klippel et al., described a case at 10 weeks of gestational age. However, they needed a second imaging at 12(th) week for confirmation. First trimester or early second trimester anatomic survey on ultrasound and MRI is accurate for the diagnosis thereby avoiding unnecessary complex pregnancy. We report a case of second trimester diagnosed sirenomelia, with detailed analysis of image findings on ultrasound and fetal MRI.

  17. Electromagnetic field and mechanical stress analysis code

    International Nuclear Information System (INIS)

    1978-01-01

    Analysis TEXMAGST is a two stage linear finite element code for the analysis of static magnetic fields in three dimensional structures and associated mechanical stresses produced by the anti J x anti B forces within these structures. The electromagnetic problem is solved in terms of magnetic vector potential A for a given current density anti J as curl 1/μ curl anti A = anti J considering the magnetic permeability as constant. The Coulombian gauge (div anti A = o) was chosen and was implemented through the use of Lagrange multipliers. The second stage of the problem - the calculation of mechanical stresses in the same three dimensional structure is solved by using the same code with few modifications - through a restart card. Body forces anti J x anti B within each element are calculated from the solution of the first stage run and represent the input to the second stage run which will give the solution for the stress problem

  18. Radiographic imaging. 4 ed.

    International Nuclear Information System (INIS)

    Chesney, D.N.; Chesney, M.O.

    1981-01-01

    This is a revised edition of the textbook previously entitled 'Radiographic Photography' and accords with the current syllabus of training for the Diploma of the Royal College of Radiographers. The aim is a non-mathematical approach to provide a guide for the student to the knowledge and understanding of the theoretical concepts which affect the quality of radiographic image; materials and practices are also reviewed, particularly in relation to the characteristics of the radiographic image, and to processing equipment and processing areas. The subject is dealt with under the following headings: the photographic process, film materials in x-ray departments, sensitometry, storage of film materials and radiographs, intensifying screens and cassettes, film processing, developing, fixing, rinsing, washing, drying, the processing area and equipment, systems for daylight film handling, the radiographic image, management of the quality, presentation of the radiograph, light images and their recording, fluorography, some special imaging processes, e.g. xerography, copying radiographs. (U.K.)

  19. A meta-analysis of clinical and radiographic outcomes of posterior horn medial meniscus root repairs.

    Science.gov (United States)

    Chung, Kyu Sung; Ha, Jeong Ku; Ra, Ho Jong; Kim, Jin Goo

    2016-05-01

    Although interest in medial meniscus posterior root tear (MMPRT) repair has increased, few case series have been reported. This meta-analysis aimed to examine the clinical and radiological effects of MMPRT repair by pooling pre- and post-operative data from case-series reports. A literature search was performed using MEDLINE/PubMed, the Cochrane Central Register of Controlled Trials, and EMBASE databases. Pre- and post-operative data were pooled to investigate the effects of MMPRT repair, including the Lysholm score improvement, meniscal extrusion (mm) reduction, progression of the Kellgren-Lawrence (K-L) grade, and cartilage status according to the Outerbridge classification. Treatment effects included paired standardized mean differences (difference in the pre- and post-operative mean outcomes divided by the standard deviation) for the Lysholm score and meniscal extrusion, as well as the pooled event rates of progression of K-L grade and cartilage status. As treatment effects, the Lysholm score increased by as much as 3.675 (P meniscus extrusion was not reduced (n.s.). The overall pooled event rates of progression of K-L grade and cartilage status were 10.6 and 17.3 % (P meniscus extrusion was not reduced. Considering the occurrence of progression of K-L grade and cartilage status, it did not prevent the progression of arthrosis completely. Based on these results, repair results in favourable outcomes for MMPRT. Meta-analysis, Level IV.

  20. Analysis of painted arts by energy sensitive radiographic techniques with the Pixel Detector Timepix

    International Nuclear Information System (INIS)

    Zemlicka, J; Jakubek, J; Kroupa, M; Hradil, D; Hradilova, J; Mislerova, H

    2011-01-01

    Non-invasive techniques utilizing X-ray radiation offer a significant advantage in scientific investigations of painted arts and other cultural artefacts such as painted artworks or statues. In addition, there is also great demand for a mobile analytical and real-time imaging device given the fact that many fine arts cannot be transported. The highly sensitive hybrid semiconductor pixel detector, Timepix, is capable of detecting and resolving subtle and low-contrast differences in the inner composition of a wide variety of objects. Moreover, it is able to map the surface distribution of the contained elements. Several transmission and emission techniques are presented which have been proposed and tested for the analysis of painted artworks. This study focuses on the novel techniques of X-ray transmission radiography (conventional and energy sensitive) and X-ray induced fluorescence imaging (XRF) which can be realised at the table-top scale with the state-of-the-art pixel detector Timepix. Transmission radiography analyses the changes in the X-ray beam intensity caused by specific attenuation of different components in the sample. The conventional approach uses all energies from the source spectrum for the creation of the image while the energy sensitive alternative creates images in given energy intervals which enable identification and separation of materials. The XRF setup is based on the detection of characteristic radiation induced by X-ray photons through a pinhole geometry collimator. The XRF method is extremely sensitive to the material composition but it creates only surface maps of the elemental distribution. For the purpose of the analysis several sets of painted layers have been prepared in a restoration laboratory. The composition of these layers corresponds to those of real historical paintings from the 19 th century. An overview of the current status of our methods will be given with respect to the instrumentation and the application in the field of

  1. Analysis of painted arts by energy sensitive radiographic techniques with the Pixel Detector Timepix

    Energy Technology Data Exchange (ETDEWEB)

    Zemlicka, J; Jakubek, J; Kroupa, M [Institute of Experimental and Applied Physics, Czech Technical University Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Hradil, D [Institute of Inorganic Chemistry, AS CR, v.v.i., ALMA, 50 68 Husinec-Oeez (Czech Republic); Hradilova, J; Mislerova, H, E-mail: jan.zemlicka@utef.cvut.cz [Academy of Fine Arts in Prague, ALMA, U Akademie 4, 170 2, Prague 7 (Czech Republic)

    2011-01-15

    Non-invasive techniques utilizing X-ray radiation offer a significant advantage in scientific investigations of painted arts and other cultural artefacts such as painted artworks or statues. In addition, there is also great demand for a mobile analytical and real-time imaging device given the fact that many fine arts cannot be transported. The highly sensitive hybrid semiconductor pixel detector, Timepix, is capable of detecting and resolving subtle and low-contrast differences in the inner composition of a wide variety of objects. Moreover, it is able to map the surface distribution of the contained elements. Several transmission and emission techniques are presented which have been proposed and tested for the analysis of painted artworks. This study focuses on the novel techniques of X-ray transmission radiography (conventional and energy sensitive) and X-ray induced fluorescence imaging (XRF) which can be realised at the table-top scale with the state-of-the-art pixel detector Timepix. Transmission radiography analyses the changes in the X-ray beam intensity caused by specific attenuation of different components in the sample. The conventional approach uses all energies from the source spectrum for the creation of the image while the energy sensitive alternative creates images in given energy intervals which enable identification and separation of materials. The XRF setup is based on the detection of characteristic radiation induced by X-ray photons through a pinhole geometry collimator. The XRF method is extremely sensitive to the material composition but it creates only surface maps of the elemental distribution. For the purpose of the analysis several sets of painted layers have been prepared in a restoration laboratory. The composition of these layers corresponds to those of real historical paintings from the 19{sup th} century. An overview of the current status of our methods will be given with respect to the instrumentation and the application in the field

  2. Analysis of Biaxially Stressed Bridge Deck Plates

    DEFF Research Database (Denmark)

    Jönsson, Jeppe; Bondum, Tommi Højer

    2012-01-01

    The ultimate state analysis of bridge deck plates at the intersection zone between main girders and transverse beams is complicated by biaxial membrane stresses, which may be in compression or tension in either direction depending on the bridge configuration and the specific location. This paper...

  3. Stress analysis of a rupture disk

    International Nuclear Information System (INIS)

    Werne, R.W.

    1975-04-01

    The results of an elastic stress analysis of the rupture disk for an internal pressure of 45.5 MPa (6600 psi) indicate that the maximum von Mises stresses occur in the membrane and are on the order of 483 to 690 MPa (70,000 psi). This far exceeds the yield of the membrane material of 207 MPa (30,000 psi). These high stresses are expected since the membrane is designed to burst at that design pressure. The von Mises stresses in the rest of the body are less than 138 MPa (20,000 psi). An elastic-plastic analysis of the membrane alone subjected to the 45.5 MPa (6600 psi) pressure indicates that it becomes plastically unstable, i.e., it continues to deform under constant load. A second load case with a constant 6.9 MPa (1000 psi) pressure throughout the entire body (i.e., after release of pressure by burst of the membrane) was analyzed. The results indicate that the elastic von Mises stresses are less than 26.7 MPa (3880 psi) throughout the body. (U.S.)

  4. Resolution requirements for monitor viewing of digital flat-panel detector radiographs: a contrast detail analysis

    International Nuclear Information System (INIS)

    Peer, Siegfried; Giacomuzzi, Salvatore M.; Peer, Regina; Gassner, Eva; Steingruber, Iris; Jaschke, Werner

    2003-01-01

    With the introduction of digital flat-panel detector systems into clinical practice, the still unresolved question of resolution requirements for picture archiving communication system (PACS) workstation monitors has gained new momentum. This contrast detail analysis was thus performed to define the differences in observer performance in the detection of small low-contrast objects on clinical 1K and 2K monitor workstations. Images of the CDRAD 2.0 phantom were acquired at varying exposures on an indirect-type digital flat-panel detector. Three observers evaluated a total of 15 images each with respect to the threshold contrast for each detail size. The numbers of correctly identified objects were determined for all image subsets. No significant difference in the correct detection ratio was detected among the observers; however, the difference between the two types of workstations (1K vs 2K monitors) despite less than 3% was significant at a 95% confidence level. Slight but statistically significant differences exist in the detection of low-contrast nodular details visualized on 1K- and 2K-monitor workstations. Further work is needed to see if this result holds true also for comparison of clinical flat-panel detector images and may, for example, exert an influence on the diagnostic accuracy of chest X-ray readings. (orig.)

  5. Occupational health and the radiographer

    International Nuclear Information System (INIS)

    Stronach, T.

    1990-01-01

    This paper identifies some of the occupational health hazards faced by radiographers in the hospital environment. There has been very little work done in this area in the past, and as the subject is so large this paper can do little other than raise some of the issues . The hazards addressed include: radiation, ergonomics, chemical, environmental, biological, occupational injury and accident, stress. 14 refs., 2 figs

  6. Histopathological, Microbiological, and Radiographic Analysis of Antimicrobial Photodynamic Therapy for the Treatment of Teeth with Apical Periodontitis: A Study in Rats' Molars.

    Science.gov (United States)

    Trindade, Alessandra Cesar; de Figueiredo, José Antônio Poli; de Oliveira, Sílvia Dias; Barth Junior, Valdir Cristóvão; Gallo, Stephanie Wagner; Follmann, Carina; Wolle, Carlos Frederico Brilhante; Steier, Liviu; Morgental, Renata Dornelles; Weber, João Batista Blessmann

    2017-07-01

    The aim of this study was to evaluate in vivo, by histological and radiographic analysis, the response of apical tissues of rats' teeth with experimentally induced apical periodontitis, after one- and two-session endodontic treatment with and without photodynamic therapy (PDT). A microbiological analysis was also performed to verify bacterial reduction after each treatment. Studies carried out in recent years highlighted the antibacterial potential of PDT when associated with conventional endodontic therapy in vitro. Although the antimicrobial effect of PDT is well-established, tissue response to PDT in teeth with apical periodontitis lacks studies. Thirty-two rats' root canals were assigned to four groups: one session/PDT-[chemomechanical preparation (CMP)+root canal filling (RCF)]; two sessions/PDT- [CMP+calcium hydroxide (CH) for 14 days+RCF]; one session/PDT+ [CMP+PDT+RCF], and two sessions/PDT+ [CMP+PDT+CH for 14 days+RCF]. For microbiological evaluation, samples were collected before and after proposed treatments. For radiographic and histological analysis, the animals were euthanized after 28 days and the mandibles surgically removed. PDT associated with conventional endodontic therapy was able to promote significant bacterial reduction in root canals with induced apical periodontitis, but this reduction was not significantly different to conventional endodontic therapy alone. Although radiographic evaluation showed no significant differences, histological analysis showed lower scores for neutrophils/eosinophils in PDT-treated groups and macrophages/giant cells in CH groups. The use of low-level laser as light source did not promote major improvement on radiographic and histological repair, but since the number of inflammatory cells slightly decreased, it may optimize repair by modulating inflammatory process. PDT may be indicated as an adjunct to conventional endodontic therapy for teeth with apical periodontitis, in association with an interappointment

  7. The Stress and Stiffness Analysis of Diaphragm

    Directory of Open Access Journals (Sweden)

    Qu Dongyue

    2017-01-01

    Full Text Available Diaphragm coupling with its simple structure, small size, high reliability, which can compensate for its input and output displacement deviation by its elastic deformation, is widely used in aerospace, marine, and chemical etc. This paper uses the ANSYS software and its APDL language to analysis the stress distribution when the diaphragm under the load of torque, axial deviation, centrifugal force, angular deviation and multiple loads. We find that the value of maximum stress usually appears in the outer or inner transition region and the axial deviation has a greater influence to the distribution of the stress. Based on above, we got three kinds of stiffness for axial, angular and torque, which the stiffness of diaphragm is nearly invariable. The results can be regard as an important reference for design and optimization of diaphragm coupling.

  8. PDX toroidal field coils stress analysis

    International Nuclear Information System (INIS)

    Nikodem, Z.D.; Smith, R.A.

    1975-01-01

    A method used in the stress analysis of the PDX toroidal field coil is developed. A multilayer coil design of arbitrary dimensions in the shape of either a circle or an oval is considered. The analytical model of the coil and the supporting coil case with connections to the main support structure is analyzed using the finite element technique. The three dimensional magnetic fields and the non-uniform body forces which are a loading condition on a coil due to toroidal and poloidal fields are calculated. The method of analysis permits rapid and economic evaluations of design changes in coil geometry as well as in coil support structures. Some results pertinent to the design evolution and their comparison are discussed. The results of the detailed stress analysis of the final coil design due to toroidal field, poloidal field and temperature loads are presented

  9. Photoelastic stress analysis in mitred bend under internal pressure

    International Nuclear Information System (INIS)

    Sawa, Yoshiaki

    1987-01-01

    The stress analysis and stress relaxation in mitred bend subjected to internal pressure have been studied by means of the photoelastic stress freezing method. The experimental results show that stress concentration occurs in the wedge tip of the intersectional plane and it is considerably influenced by the bent angle. Then, the stress relaxation was obtained by planing the wedge tip. (author)

  10. Complete stress tensor determination by microearthquake analysis

    Science.gov (United States)

    Slunga, R.

    2010-12-01

    the depth based on the assumptions of a fractured crust, widely vary ing stress field, and a general closeness to instability as found by stress measurements (Jamison and Cook 1976). Wheather this approach is working or not is best answered by applying it to real data. This was provided by the IMO network in Iceland. Along Southern Iceland Seismic Zone (SISZ) more than 200,000 microearthquakes and a few M 5 EQs and 2 M=6.6 EQs have been recorded. The results will be presented it is obvious that the use of the stresses determined from the microearthquake recordings may significa ntly improve earthquake warnings and will make it possible to use the absolute C FS method for more deterministic predictions. Note that the microearthquake meth od only shows the part of the stress field that has caused slip. Volumes with st able stress will not show up. However stress measurements (Brown and Hoek 1978, Slunga 1988) have shown that the crustal stresses in general are close to instabi lity and microearthquake source analysis has shown that a large number of differ ent fractures become unstable within longer time windows. This may explain the e xcellent results given by the Icelandic tests of the absolute stress tensor fiel d as given by the microearthquakes. However I prefer to call this stress apparen t.

  11. Quality of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    This chapter discussed on how to get a good radiograph. There are several factors that can make good radiograph such as density of radiograph, the contrast of radiograph, definition of radiograph, the present of artifact and backscattering. All of this factor will discuss detailed on each unit of chapter with some figure, picture to make the reader understand more when read this book. And at the end, the reader will introduce with penetrameter, one of device to determine the level of quality of the radiograph. There are two type of penetrameter like wire type or holes type. This standard must be followed by all the radiographer around the world to produce the good result that is standard and more reliable.

  12. PACS influence the radiographer's work

    International Nuclear Information System (INIS)

    Fridell, Kent; Aspelin, Peter; Edgren, Lars; Lindskoeld, Lars; Lundberg, Nina

    2009-01-01

    a new PACS technology and digital workflow. Using PACS technology, together with an adjustment to the new system workflow, the experience among radiographers was that the production of images increased and as a result the stress in work increased as well. Using PACS technology, medical staff had little control over the organization of image production and its workflow, so that radiographers experienced PACS as a more technical deterministic system allowing small human control in the organization of work.

  13. Total elbow arthroplasty: a radiographic outcome study

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Xue Susan [University of Washington, Department of Radiology, Box 357115, Seattle, WA (United States); Petscavage-Thomas, Jonelle M. [Penn State Hershey Medical Center, Department of Radiology, Hershey, PA (United States); Ha, Alice S. [University of Washington, Department of Radiology, Box 354755, Seattle, WA (United States)

    2016-06-15

    Total elbow arthroplasty (TEA) is becoming a popular alternative to arthrodesis for patients with end-stage elbow arthrosis and comminuted distal humeral fractures. Prior outcome studies have primarily focused on surgical findings. Our purpose is to determine the radiographic outcome of TEA and to correlate with clinical symptoms such as pain. This is an IRB-approved retrospective review from 2005 to 2015 of all patients with semiconstrained TEA. All available elbow radiographs and clinical data were reviewed. Data analysis included descriptive statistics and Kaplan-Meier survival curves for radiographic and clinical survival. A total of 104 total elbow arthroplasties in 102 patients were reviewed; 75 % were in women and the mean patient age was 63.1 years. Mean radiographic follow-up was 826 days with average of four radiographs per patient. Seventy TEAs (67 %) developed radiographic complications, including heterotopic ossification (48 %), perihardware lucency (27 %), periprosthetic fracture (23 %), hardware subluxation/dislocation (7 %), polyethylene wear (3 %), and hardware fracture/dislodgement (3 %); 56 patients (55 %) developed symptoms of elbow pain or instability and 30 patients (30 %) underwent at least one reoperation. In patients with radiographic complications, 66 % developed elbow pain, compared to 19 % of patients with no radiologic complications (p = 0.001). Of the patients with radiographic complications, 39 % had at least one additional surgery compared to 0 % of patients without radiographic complications (p = 0.056). Radiographic complications are common in patients after total elbow arthroplasty. There is a strong positive association between post-operative radiographic findings and clinical outcome. Knowledge of common postoperative radiographic findings is important for the practicing radiologist. (orig.)

  14. Cephalometric-radiographic study, in lateral norm, considering the established standards of white Brazilian teenagers who presented normal occlusions and mal-occlusions of Class I and Class II, 1st Division and the ones from Ricketts' analysis

    International Nuclear Information System (INIS)

    Bismarck, V.E.

    1986-01-01

    In the present work, our purpose was make a cephalometric-radiographic study, comparing white Brazilian teenagers who presented normal occlusion and the ones who presented malocclusions of Class I and Class II, according to RICKETT'S analysis (1960). (author) [pt

  15. Radiographer commenting of trauma radiographs: a survey of the benefits, barriers and enablers to participation in an Australian healthcare setting

    International Nuclear Information System (INIS)

    Neep, Michael J.; Steffens, Tom; Owen, Rebecca; McPhail, Steven M.

    2014-01-01

    Radiographer abnormality detection systems that highlight abnormalities on trauma radiographs ('red dot' system) have been operating for more than 30 years. Recently, a number of pitfalls have been identified. These limitations initiated the evolution of a radiographer commenting system, whereby a radiographer provides a brief description of abnormalities identified in emergency healthcare settings. This study investigated radiographers' participation in abnormality detection systems, their perceptions of benefits, barriers and enablers to radiographer commenting, and perceptions of potential radiographer image interpretation services for emergency settings. A cross-sectional survey was implemented. Participants included radiographers from four metropolitan hospitals in Queensland, Australia. Conventional descriptive statistics, histograms and thematic analysis were undertaken. Seventy-three surveys were completed and included in the analysis (68% response rate); 30 (41%) of respondents reported participating in abnormality detection in 20% or less of examinations, and 26(36%) reported participating in 80% or more of examinations. Five overarching perceived benefits of radiographer commenting were identified: assisting multidisciplinary teams, patient care, radiographer ability, professional benefits and quality of imaging. Frequently reported perceived barriers included 'difficulty accessing image interpretation education', 'lack of time' and 'low confidence in interpreting radiographs'. Perceived enablers included 'access to image interpretation education' and 'support from radiologist colleagues'. A range of factors are likely to contribute to the successful implementation of radiographer commenting in addition to abnormality detection in emergency settings. Effective image interpretation education amenable to completion by radiographers would likely prove valuable in preparing radiographers for participation in abnormality detection and commenting systems in

  16. Piping stress analysis with personal computers

    International Nuclear Information System (INIS)

    Revesz, Z.

    1987-01-01

    The growing market of the personal computers is providing an increasing number of professionals with unprecedented and surprisingly inexpensive computing capacity, which if using with powerful software, can enhance immensely the engineers capabilities. This paper focuses on the possibilities which opened in piping stress analysis by the widespread distribution of personal computers, on the necessary changes in the software and on the limitations of using personal computers for engineering design and analysis. Reliability and quality assurance aspects of using personal computers for nuclear applications are also mentioned. The paper resumes with personal views of the author and experiences gained during interactive graphic piping software development for personal computers. (orig./GL)

  17. Radiographic analysis of the correlation between ossification of the nuchal ligament and sagittal alignment and segmental stability of the cervical spine in patients with cervical spondylotic myelopathy.

    Science.gov (United States)

    Ying, Jinwei; Teng, Honglin; Qian, Yunfan; Hu, Yingying; Wen, Tianyong; Ruan, Dike; Zhu, Minyu

    2018-01-01

    Background Ossification of the nuchal ligament (ONL) caused by chronic injury to the nuchal ligament (NL) is very common in instability-related cervical disorders. Purpose To determine possible correlations between ONL, sagittal alignment, and segmental stability of the cervical spine. Material and Methods Seventy-three patients with cervical spondylotic myelopathy (CSM) and ONL (ONL group) and 118 patients with CSM only (control group) were recruited. Radiographic data included the characteristics of ONL, sagittal alignment and segmental stability, and ossification of the posterior longitudinal ligament (OPLL). We performed comparisons in terms of radiographic parameters between the ONL and control groups. The correlations between ONL size, cervical sagittal alignment, and segmental stability were analyzed. Multivariate logistic regression was used to identify the independent risk factors of the development of ONL. Results C2-C7 sagittal vertical axis (SVA), T1 slope (T1S), T1S minus cervical lordosis (T1S-CL) on the lateral plain, angular displacement (AD), and horizontal displacement (HD) on the dynamic radiograph increased significantly in the ONL group compared with the control group. The size of ONL significantly correlated with C2-C7 SVA, T1S, AD, and HD. The incidence of ONL was higher in patients with OPLL and segmental instability. Cervical instability, sagittal malalignment, and OPLL were independent predictors of the development of ONL through multivariate analysis. Conclusion Patients with ONL are more likely to have abnormal sagittal alignment and instability of the cervical spine. Thus, increased awareness and appreciation of this often-overlooked radiographic finding is warranted during diagnosis and treatment of instability-related cervical pathologies and injuries.

  18. Systematic review and meta-analysis of the value of clinical features to exclude radiographic pneumonia in febrile neutropenic episodes in children and young people.

    Science.gov (United States)

    Phillips, Bob; Wade, Ros; Westwood, Marie; Riley, Richard; Sutton, Alex J

    2012-08-01

      Children and young people who present with febrile neutropenia (FNP) secondary to malignancies or their treatment frequently do not undergo routine chest radiography. With shorter courses of antibiotic therapy, failure to recognise pneumonia and consequent under-treatment could produce significant problems.   The review was conducted determine the value of the absence of clinical features of lower respiratory tract infection in excluding radiographic pneumonia at presentation of FNP using Centre for Reviews and Dissemination methods. It was registered with the HTA Registry of systematic reviews, CRD32009100453. Ten bibliographic databases, conference proceedings, reference lists and citations were searched. Cohort studies which compared clinical examination to radiographic findings were included. Results were summarised by random-effects meta-analysis.   Four studies were included. Synthesis of the three higher-quality studies gave imprecise estimates of the average sensitivity (75%; 95% CI 52% to 89%) and average specificity (69%; 95% CI 57% to 78%) for clinical examination in the detection of radiographic pneumonia. If the prevalence of pneumonia is 5%, these estimates produce a negative predictive value of 98% (95% CI 96% to 99%). Alternatively, there remains a 1.9% probability of pneumonia (95% CI 0.7% to 4.2%).   Signs and symptoms of lower respiratory infection have only moderate sensitivity and specificity for pneumonia; the low prevalence of the condition justifies the routine withholding of chest radiographs. However, for those with a predisposition to pneumonia, or re-presenting after a short course of antibiotic therapy, a chest X-ray should be performed despite an absence of signs. © 2011 The Authors. Journal of Paediatrics and Child Health © 2011 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  19. Fast radiographic systems

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1984-08-01

    Industrial radiography can be performed with shorter exposure times, when instead of X-ray film with lead intensifying screens the radiographic paper with fluorescent screen is used. With paper radiography one can obtain lower material, equipment, and labor costs, shorter exposure and processing times, and easier radiation protection. The speed of the radiographic inspection can also be increased by the use of fluorometallic intensifying screens together with a special brand of X-ray film. Before accepting either of the two fast radiographic systems one must be sure that they can produce radiographs of adequate image quality. Therefore an investigation was performed on that subject using ISO wire IQI's and ASTM penetrameters. The radiographic image quality was tested for aluminium and steel up to 30 mm thick using various brands of radiographic paper and X-ray film with fluorometallic screens and comparing them with fast X-ray films with lead screens. Both systems give satisfactory results. (author)

  20. Stress analysis of cylinder to cylinder intersections

    International Nuclear Information System (INIS)

    Revesz, Z.

    1983-01-01

    Cylinder to cylinder intersections have numerous applications in the power industry from different piping junctions to pressure vessel nozzles. A specific purpose computer program has been installed at the author's establishment for finite element analysis of such geometries. Some of the experiences are presented giving a short overview of the analysis of unreinforced man-holes, demonstrating how a more economical design has been verified by analysis. The program installed has linear-elastic and elasto-plastic capabilities. Further, it is prepared for heat transfer analysis with subsequent thermal stress computation. An efficient pre- and post-processor has also been installed and enhanced by the author. The software used is at its present stage capable for problem definition with input data such as outside/ inside diameters, length and number of subdivisions. Similarly simple is the load definition and the graphic representation of the full output. (author)

  1. Meta-analysis of Clinical and Radiographic Outcomes After Arthroscopic Single-Row Versus Double-Row Rotator Cuff Repair

    OpenAIRE

    Perser, Karen; Godfrey, David; Bisson, Leslie

    2011-01-01

    Context: Double-row rotator cuff repair methods have improved biomechanical performance when compared with single-row repairs. Objective: To review clinical outcomes of single-row versus double-row rotator cuff repair with the hypothesis that double-row rotator cuff repair will result in better clinical and radiographic outcomes. Data Sources: Published literature from January 1980 to April 2010. Key terms included rotator cuff, prospective studies, outcomes, and suture techniques. Study Sele...

  2. Radiographic constant exposure technique

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1985-01-01

    The constant exposure technique has been applied to assess various industrial radiographic systems. Different X-ray films and radiographic papers of two producers were compared. Special attention was given to fast film and paper used with fluorometallic screens. Radiographic image quality...... was tested by the use of ISO wire IQI's and ASTM penetrameters used on Al and Fe test plates. Relative speed and reduction of kilovoltage obtained with the constant exposure technique were calculated. The advantages of fast radiographic systems are pointed out...

  3. Visual simulation of radiographs

    International Nuclear Information System (INIS)

    Laguna, G.

    1985-01-01

    A method for computer simulation of radiographs has been added to the LLNL version of the solid modeler TIPS-1 (Technical Information Processing System-1). This new tool will enable an engineer to compare an actual radiograph of a solid to its computer-generated counterpart. The appearance of discrepancies between the two can be an indication of flaws in the solid object. Simulated radiographs can also be used to preview the placement of x-ray sources to focus on areas of concern before actual radiographs are made

  4. The description of condyle position in disc displacement with reduction using Cone Beam Computed Tomography 3D radiographic analysis

    Directory of Open Access Journals (Sweden)

    Liana Rahmayani

    2009-07-01

    Full Text Available One of the temporomandibular joint disorders that mostly occurs is disc displacement with reduction. Disc displacement that causes the displacement of condyle position can be evaluated by using radiograph. The Cone Beam Computed Tomography (CBCT-3D is a radiograph equipment which is able to capture the condyle position from many directions. This research was aimed to see the condyle position in patients with disc displacement with reduction symptoms. This research was conducted to 11 patients with symptoms of disc displacement with reduction and 3 patients without symptoms of disc displacement with reduction as the counterpart. What was conducted to the sample was the radiographic imaging using CBCT-3D radiography, followed by measuring the joint space distance in the sagittal and coronal directions. The result of the research was analyzed using the T-test. Statistically, the result of the test showed a significant difference ( = 0.05 between patients with disc displacement with reduction symptoms and the patients without symptoms, in sagittal and coronal views. The conclusion led to the difference in condyle positions in patients with the disc displacement with reduction and patients without the symptoms which meant there was a condyle position displacement that caused the distance alteration in joint space in sagittal and coronal directions.

  5. Radiographically detectable intracortical porosity

    International Nuclear Information System (INIS)

    Meema, H.E.

    1986-01-01

    Since the measurement of intracortical resorptive spaces by histologic methods is difficult and very few data are available in normal humans, we have measured their lengths and widths and calculated the intracortical porosity in metacarpals and phalanges of 79 normal women and 69 normal men, using fine-detail radiographs of the hands and a computerized semi-automatic image analysis system (Zeiss MOP-3), this being the first study of this kind. Several methodological problems were solved satisfactorily, and the results of this study could serve as a data bank for further investigations concerned with intracortical resorption. Significant differences were found between age and sex versus several intracortical resorptive parameters; also significant correlations were found with age in some cases. Normal intracortical porosity was found to be about three times greater in the proximal phalanges than in the metacarpals. It is concluded that this methodology could be used for further studies of intracortical resorption in osteoporosis and other metabolic bone diseases. (orig.)

  6. Legalities of the radiograph

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    The radiograph itself plays a major role in medical malpractice cases. Also, many questions arise concerning the rights to and storage of x-ray films. These issues are addressed in this chapter. To keep the terminology simple, the word radiograph represents all imaging documentation on hard copy film (x-rays, nuclear medicine, computer-assisted studies, ultrasound, and magnetic resonance imaging)

  7. Radiographic progression with nonrising PSA in metastatic castration-resistant prostate cancer: post hoc analysis of PREVAIL.

    Science.gov (United States)

    Bryce, A H; Alumkal, J J; Armstrong, A; Higano, C S; Iversen, P; Sternberg, C N; Rathkopf, D; Loriot, Y; de Bono, J; Tombal, B; Abhyankar, S; Lin, P; Krivoshik, A; Phung, D; Beer, T M

    2017-06-01

    Advanced prostate cancer is a phenotypically diverse disease that evolves through multiple clinical courses. PSA level is the most widely used parameter for disease monitoring, but it has well-recognized limitations. Unlike in clinical trials, in practice, clinicians may rely on PSA monitoring alone to determine disease status on therapy. This approach has not been adequately tested. Chemotherapy-naive asymptomatic or mildly symptomatic men (n=872) with metastatic castration-resistant prostate cancer (mCRPC) who were treated with the androgen receptor inhibitor enzalutamide in the PREVAIL study were analyzed post hoc for rising versus nonrising PSA (empirically defined as >1.05 vs ⩽1.05 times the PSA level from 3 months earlier) at the time of radiographic progression. Clinical characteristics and disease outcomes were compared between the rising and nonrising PSA groups. Of 265 PREVAIL patients with radiographic progression and evaluable PSA levels on the enzalutamide arm, nearly one-quarter had a nonrising PSA. Median progression-free survival in this cohort was 8.3 months versus 11.1 months in the rising PSA cohort (hazard ratio 1.68; 95% confidence interval 1.26-2.23); overall survival was similar between the two groups, although less than half of patients in either group were still at risk at 24 months. Baseline clinical characteristics of the two groups were similar. Non-rising PSA at radiographic progression is a common phenomenon in mCRPC patients treated with enzalutamide. As restaging in advanced prostate cancer patients is often guided by increases in PSA levels, our results demonstrate that disease progression on enzalutamide can occur without rising PSA levels. Therefore, a disease monitoring strategy that includes imaging not entirely reliant on serial serum PSA measurement may more accurately identify disease progression.

  8. Synovial tissue and serum biomarkers of disease activity, therapeutic response and radiographic progression: analysis of a proof-of-concept randomised clinical trial of cytokine blockade.

    LENUS (Irish Health Repository)

    Rooney, Terence

    2012-02-01

    OBJECTIVES: To evaluate synovial tissue and serum biomarkers of disease activity, therapeutic response and radiographic progression during biological therapy for rheumatoid arthritis (RA). METHODS: Patients with active RA entered a randomised study of anakinra 100 mg\\/day, administered as monotherapy or in combination with pegsunercept 800 microg\\/kg twice a week. Arthroscopic synovial tissue biopsies were obtained at baseline and two further time points. Following immunohistochemical staining, selected mediators of RA pathophysiology were quantified using digital image analysis. Selected mediators were also measured in the serum. RESULTS: Twenty-two patients were randomly assigned: 11 received monotherapy and 11 combination therapy. American College of Rheumatology 20, 50 and 70 response rates were 64%, 64% and 46% with combination therapy and 36%, 9% and 0% with monotherapy, respectively. In synovial tissue, T-cell infiltration, vascularity and transforming growth factor beta (TGFbeta) expression demonstrated significant utility as biomarkers of disease activity and therapeutic response. In serum, interleukin 6 (IL-6), matrix metalloproteinase (MMP) 1, MMP-3 and tissue inhibitor of metalloproteinase 1 (TIMP-1) were most useful in this regard. An early decrease in serum levels of TIMP-1 was predictive of the later therapeutic outcome. Pretreatment tissue levels of T-cell infiltration and the growth factors vascular endothelial growth factor\\/TGFbeta, and serum levels of IL-6, IL-8, MMP-1, TIMP-1, soluble tumour necrosis factor receptor types I and II and IL-18 correlated with radiographic progression. CONCLUSIONS: Synovial tissue analysis identified biomarkers of disease activity, therapeutic response and radiographic progression. Biomarker expression in tissue was independent of the levels measured in the serum.

  9. Stress Analysis for Mobile Hot Cell Design

    International Nuclear Information System (INIS)

    Muhammad Hannan Bahrin; Anwar Abdul Rahman; Mohd Arif Hamzah

    2015-01-01

    Prototype and Plant Development Centre (PDC) is developing a Mobile Hot Cell (MHC) to handle and manage Spent High Activity Radioactive Sources (SHARS), such as teletherapy heads and dry irradiators. At present, there are two units of MHC in the world, one in South Africa and the other one in China. Malaysian Mobile MHC is developed by Malaysian Nuclear Agency with the assistance of IAEA expert, based on the design of South Africa and China, but with improved features. Stress analysis has been performed on the design to fulfill the safety requirement in MHC operation. This paper discusses the loading effect analysis from the radiation shielding materials to the MHC wall structure, roof supporting column and window structure. (author)

  10. Spartan Release Engagement Mechanism (REM) stress and fracture analysis

    Science.gov (United States)

    Marlowe, D. S.; West, E. J.

    1984-01-01

    The revised stress and fracture analysis of the Spartan REM hardware for current load conditions and mass properties is presented. The stress analysis was performed using a NASTRAN math model of the Spartan REM adapter, base, and payload. Appendix A contains the material properties, loads, and stress analysis of the hardware. The computer output and model description are in Appendix B. Factors of safety used in the stress analysis were 1.4 on tested items and 2.0 on all other items. Fracture analysis of the items considered fracture critical was accomplished using the MSFC Crack Growth Analysis code. Loads and stresses were obtaind from the stress analysis. The fracture analysis notes are located in Appendix A and the computer output in Appendix B. All items analyzed met design and fracture criteria.

  11. A review of residual stress analysis using thermoelastic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, A F; Dulieu-Barton, J M; Quinn, S [University of Southampton, School of Engineering Sciences, Highfield, Southampton, SO17 1BJ (United Kingdom); Burguete, R L [Airbus UK Ltd., New Filton House, Filton, Bristol, BS99 7AR (United Kingdom)

    2009-08-01

    Thermoelastic Stress Analysis (TSA) is a full-field technique for experimental stress analysis that is based on infra-red thermography. The technique has proved to be extremely effective for studying elastic stress fields and is now well established. It is based on the measurement of the temperature change that occurs as a result of a stress change. As residual stress is essentially a mean stress it is accepted that the linear form of the TSA relationship cannot be used to evaluate residual stresses. However, there are situations where this linear relationship is not valid or departures in material properties due to manufacturing procedures have enabled evaluations of residual stresses. The purpose of this paper is to review the current status of using a TSA based approach for the evaluation of residual stresses and to provide some examples of where promising results have been obtained.

  12. A review of residual stress analysis using thermoelastic techniques

    International Nuclear Information System (INIS)

    Robinson, A F; Dulieu-Barton, J M; Quinn, S; Burguete, R L

    2009-01-01

    Thermoelastic Stress Analysis (TSA) is a full-field technique for experimental stress analysis that is based on infra-red thermography. The technique has proved to be extremely effective for studying elastic stress fields and is now well established. It is based on the measurement of the temperature change that occurs as a result of a stress change. As residual stress is essentially a mean stress it is accepted that the linear form of the TSA relationship cannot be used to evaluate residual stresses. However, there are situations where this linear relationship is not valid or departures in material properties due to manufacturing procedures have enabled evaluations of residual stresses. The purpose of this paper is to review the current status of using a TSA based approach for the evaluation of residual stresses and to provide some examples of where promising results have been obtained.

  13. X-ray stress analysis of residual stress gradients in surface layers of steel

    International Nuclear Information System (INIS)

    Ganev, N.; Kraus, I.; Gosmanova, G.; Pfeiffer, L.; Tietz, H.-D.

    2001-01-01

    The aim of the contribution is to present the theoretical possibilities of X-ray non-destructive identification of stress gradients within the penetration depth of used radiation and its utilization for experimental stress analysis. Practical usefullness of outlined speculations is illustrated with results of stress measurements on cut and shot-penned steel samples. (author)

  14. Small animals bone density and morphometry analysis with a dual energy X-rays absorptiometry bone densitometer using a 2D digital radiographic detector

    International Nuclear Information System (INIS)

    Boudousq, V.; Bordy, T.; Gonon, G.; Dinten, J.M.

    2004-01-01

    LEXXOS (DMS, Montpellier, France) is the first axial and total body cone beam bone densitometer using a 2D digital radiographic detector. In previous papers, technical principles and patients' Bone Mineral Density (BMD) measurement performances were presented. Bone densitometers are also used on small animals for drug development. In this presentation, we show how LEXXOS can be adapted for small animals' examinations and evaluate its performances. At first, in order to take advantage of the whole area of the 20 x 20 cm 2 digital radiographic detector, it has been made profit of X-Rays magnification by adapting the geometrical configuration. Secondly, as small animals present low BMD, a specific dual energy calibration has been defined. This adapted system has then been evaluated on two sets of mice: six reference mice and six ovariectomized mice. Each month, these two populations have been examined and the averaged total body BMD has been measured. This evaluation shows that the right order of BMD magnitude is obtained and, as expected, BMD increases on two sets until a period around puberty and the ovariectomized set presents a significant decrease after. Moreover, the bone image obtained by dual energy processing on LEXXOS presents a radiographic image quality providing useful complementary information on bone morphometry and architecture. This study shows that LEXXOS cone beam bone densitometer provides simultaneously useful quantitative and qualitative information for analysis of bone evolution on small animals. In the future, same system architecture and processing methodology can be used with higher resolution detectors in order to refine information on bone architecture. (authors)

  15. Three-dimensional reconstruction of the human spine from bi-planar radiographs: using multiscale wavelet analysis and spline interpolators for semi-automation

    Science.gov (United States)

    Deschenes, Sylvain; Godbout, Benoit; Branchaud, Dominic; Mitton, David; Pomero, Vincent; Bleau, Andre; Skalli, Wafa; de Guise, Jacques A.

    2003-05-01

    We propose a new fast stereoradiographic 3D reconstruction method for the spine. User input is limited to few points passing through the spine on two radiographs and two line segments representing the end plates of the limiting vertebrae. A 3D spline that hints the positions of the vertebrae in space is then generated. We then use wavelet multi-scale analysis (WMSA) to automatically localize specific features in both lateral and frontal radiographs. The WMSA gives an elegant spectral investigation that leads to gradient generation and edge extraction. Analysis of the information contained at several scales leads to the detection of 1) two curves enclosing the vertebral bodies' walls and 2) inter-vertebral spaces along the spine. From this data, we extract four points per vertebra per view, corresponding to the corners of the vertebral bodies. These points delimit a hexahedron in space where we can match the vertebral body. This hexahedron is then passed through a 3D statistical database built using local and global information generated from a bank of normal and scoliotic spines. Finally, models of the vertebrae are positioned with respect to these landmarks, completing the 3D reconstruction.

  16. FEA stress analysis for SAFKEG 2863B

    International Nuclear Information System (INIS)

    Puckett, A.

    1997-01-01

    This report covers the evaluation of the structural design of the two stainless steel containment vessels in CROFT SAFKEG Model Number 2863B, for conformance to the design criteria of the NRC Regulatory Guide 7.6, NRC Regulatory Guide 7.8, and the applicable requirements of the ASME Boiler and Pressure Vessel Code, Section 3, and Section 8. The two containment vessels are designated Cans 2870 and 2871. Each of these containment vessels was analyzed for the loadings specified in chapter 2, Section 2.1.2 of the SARP. Structural assessment of Cans 2870 and 2871 due to loading considerations beyond the evaluation of pressure and temperature are presented. This report is organized as follows: (1) overview of the design of each containment vessel and pressure boundary; (2) brief description of both containment vessels; (3) discussion of normal and accident conditions; (4) analysis assumptions; (5) detailed structural evaluation of each component of each containment vessel; (6) demonstration of compliance to Regulatory Guide 7.6 stress evaluations; (7) demonstration of compliance to Regulatory Guide 7.8 loading combinations; and (8) summary of the calculated stresses, comparison with design allowables, estimates of margins of safety and a summary of results and conclusions

  17. Producing quality radiographic images

    International Nuclear Information System (INIS)

    Cullinan, A.M.

    1987-01-01

    This book gives an overview of physics, equipment, imaging, and quality assurance in the radiology department. The chapters are laid out with generous use of subheads to allow for quick reference, Points are illustrated with clear, uncluttered line diagrams and well-produced images. The accompanying explanations are miniature lessons by themselves. Inserted at various points throughout the text are important notes that highlight key concepts. The chapter ''Image Evaluation and Application of Radiographic Principles'' present a systematic approach to evaluating radiographs and contains several sample radiographs to illustrate the points made

  18. Plantar calcaneal enthesophytes: new observations regarding sites of origin based on radiographic, MR imaging, anatomic, and paleopathologic analysis

    International Nuclear Information System (INIS)

    Abreu, M.R.; Chung, C.B.; Mendes, L.; Mohana-Borges, A.; Trudell, D.; Resnick, D.

    2003-01-01

    To determine the relationship between sites of calcaneal plantar enthesophytes and surrounding fascial and soft tissue structures using routine radiography, MR imaging, and data derived from cadaveric and paleopathologic specimens.Design and patients. Two observers analyzed the MR imaging studies of 40 ankles in 38 patients (35 males, 3 females; mean age 48.3 years) with plantar calcaneal enthesophytes that were selected from all the ankle MR examinations performed during the past year. Data derived from these MR examinations were the following: the size of the enthesophyte; its location in relation to the plantar fascia (PF) and flexor muscles; and the thickness and signal of the PF. The corresponding radiographs of the ankles were evaluated at a different time by the same observers for the presence or absence of plantar enthesophytes and, when present, their measurements. A third observer reviewed all the discordant observations of MR imaging and radiographic examinations. Two observers analyzed 22 calcaneal specimens with plantar enthesophytes at an anthropology museum to determine the orientation of each plantar enthesophyte. MR imaging of a cadaveric foot with a plantar enthesophyte with subsequent sagittal sectioning was performed to provide further anatomic understanding.Results. With regard to MR imaging, the mean size of the plantar enthesophytes was 4.41 mm (SD 2.4). Twenty (50%) enthesophytes were located above the PF, 16 (40%) between the fascia and abductor digiti minimi, flexor digitorum brevis and abductor hallucis muscles, and only one (3%) was located within the PF. In three (8%) cases the location was not determined. The size of enthesophytes seen with MR imaging and radiographs was highly correlated (P 0.8, kappa >0.9). Eleven of the 22 bone specimens had plantar enthesophytes oriented in the direction of the abductor digiti minimi and 11 oriented in the direction of the flexor digitorum brevis and PF. The cadaveric sections revealed different

  19. Plantar calcaneal enthesophytes: new observations regarding sites of origin based on radiographic, MR imaging, anatomic, and paleopathologic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, M.R.; Chung, C.B.; Mendes, L.; Mohana-Borges, A.; Trudell, D.; Resnick, D. [Department of Radiology, Musculoskeletal Section, VA San Diego Healthcare System, 3350 La Jolla Village Drive, San Diego, CA 92161 (United States)

    2003-01-01

    To determine the relationship between sites of calcaneal plantar enthesophytes and surrounding fascial and soft tissue structures using routine radiography, MR imaging, and data derived from cadaveric and paleopathologic specimens.Design and patients. Two observers analyzed the MR imaging studies of 40 ankles in 38 patients (35 males, 3 females; mean age 48.3 years) with plantar calcaneal enthesophytes that were selected from all the ankle MR examinations performed during the past year. Data derived from these MR examinations were the following: the size of the enthesophyte; its location in relation to the plantar fascia (PF) and flexor muscles; and the thickness and signal of the PF. The corresponding radiographs of the ankles were evaluated at a different time by the same observers for the presence or absence of plantar enthesophytes and, when present, their measurements. A third observer reviewed all the discordant observations of MR imaging and radiographic examinations. Two observers analyzed 22 calcaneal specimens with plantar enthesophytes at an anthropology museum to determine the orientation of each plantar enthesophyte. MR imaging of a cadaveric foot with a plantar enthesophyte with subsequent sagittal sectioning was performed to provide further anatomic understanding.Results. With regard to MR imaging, the mean size of the plantar enthesophytes was 4.41 mm (SD 2.4). Twenty (50%) enthesophytes were located above the PF, 16 (40%) between the fascia and abductor digiti minimi, flexor digitorum brevis and abductor hallucis muscles, and only one (3%) was located within the PF. In three (8%) cases the location was not determined. The size of enthesophytes seen with MR imaging and radiographs was highly correlated (P<0.01). The interobserver agreement for all measurements was good (Pearson >0.8, kappa >0.9). Eleven of the 22 bone specimens had plantar enthesophytes oriented in the direction of the abductor digiti minimi and 11 oriented in the direction of the

  20. Effect of Glucocorticoids on the Clinical and Radiographic Efficacy of Tofacitinib in Patients with Rheumatoid Arthritis: A Posthoc Analysis of Data from 6 Phase III Studies.

    Science.gov (United States)

    Charles-Schoeman, Christina; van der Heijde, Désirée; Burmester, Gerd R; Nash, Peter; Zerbini, Cristiano A F; Connell, Carol A; Fan, Haiyun; Kwok, Kenneth; Bananis, Eustratios; Fleischmann, Roy

    2018-02-01

    Tofacitinib has been investigated for the treatment of rheumatoid arthritis (RA) in phase III studies in which concomitant glucocorticoids (GC) were allowed. We analyzed the effect of GC use on efficacy outcomes in patients with RA receiving tofacitinib and/or methotrexate (MTX) or conventional synthetic disease-modifying antirheumatic drugs (csDMARD) in these studies. Our posthoc analysis included data from 6 phase III studies (NCT01039688; NCT00814307; NCT00847613; NCT00853385; NCT00856544; NCT00960440). MTX-naive patients or patients with inadequate response to csDMARD or biological DMARD received tofacitinib 5 or 10 mg twice daily alone or with csDMARD, with or without concomitant GC. Patients receiving GC (≤ 10 mg/day prednisone or equivalent) before enrollment maintained a stable dose throughout. Endpoints included the American College of Rheumatology (ACR) 20/50/70 response rates, rates of Clinical Disease Activity Index (CDAI)-defined low disease activity (LDA; CDAI ≤ 10) and remission (CDAI ≤ 2.8), and changes from baseline in CDAI, 28-joint count Disease Activity Score (DAS28-4)-erythrocyte sedimentation rate (ESR), Health Assessment Questionnaire-Disability Index (HAQ-DI), pain visual analog scale (VAS), and modified total Sharp score. Of 3200 tofacitinib-treated patients, 1258 (39.3%) received tofacitinib monotherapy and 1942 (60.7%) received tofacitinib plus csDMARD; 1767 (55.2%) received concomitant GC. ACR20/50/70 response rates, rates of CDAI LDA and remission, and improvements in CDAI, DAS28-4-ESR, HAQ-DI, and pain VAS with tofacitinib were generally similar with or without GC in monotherapy and combination therapy studies. GC use did not appear to affect radiographic progression in tofacitinib-treated MTX-naive patients. MTX plus GC appeared to inhibit radiographic progression to a numerically greater degree than MTX alone. Concomitant use of GC with tofacitinib did not appear to affect clinical or radiographic efficacy. MTX plus GC showed a

  1. Rapidly processable radiographic material

    International Nuclear Information System (INIS)

    Brabandere, L.A. de; Borginon, H.A.; Pattyn, H.A.; Pollet, R.J.

    1981-01-01

    A new rapidly processable radiographic silver halide material is described for use in mammography and non-destructive testing of industrial materials. The radiographic material is used for direct exposure to penetrating radiation without the use of fluorescent-intensifying screens. It consists of a transparent support with a layer of hydrophilic colloid silver halide emulsion on one or both sides. Examples of the preparation of three different silver halide emulsions are given including the use of different chemical sensitizers. These new radiographic materials have good resistance to the formation of pressure marks in rapid processing apparatus and they have improved sensitivity for direct exposure to penetrating radiation compared to conventional radiographic emulsions. (U.K.)

  2. Privacy and Psychosomatic Stress: An Empirical Analysis.

    Science.gov (United States)

    Webb, Stephen D.

    1978-01-01

    Examines the supposition that insufficient privacy is stressful to the individual. Data were obtained from urban centers in New Zealand. Findings support the hypothesis that a percieved lack of privacy is associated with psychosomatic stress. The relationship is specified by measures of stress and sex of respondents. (Author)

  3. Yield stress fluids slowly yield to analysis

    NARCIS (Netherlands)

    Bonn, D.; Denn, M.M.

    2009-01-01

    We are surrounded in everyday life by yield stress fluids: materials that behave as solids under small stresses but flow like liquids beyond a critical stress. For example, paint must flow under the brush, but remain fixed in a vertical film despite the force of gravity. Food products (such as

  4. A radiographic analysis of alignment of the lower extremities--initiation and progression of varus-type knee osteoarthritis.

    Science.gov (United States)

    Matsumoto, T; Hashimura, M; Takayama, K; Ishida, K; Kawakami, Y; Matsuzaki, T; Nakano, N; Matsushita, T; Kuroda, R; Kurosaka, M

    2015-02-01

    This study aimed to investigate alignment based on age in normal knees and alignment based on deformity in osteoarthritis (OA) knees using detailed radiographic parameters. Various parameters were measured from weight-bearing long leg radiographs of 1251 legs (797 normal and 454 OA knees) as a cross-sectional study. Normal knees were classified by age (young, middle aged, aged, and elderly) and symptomatic OA knees on the basis of the alignment (femorotibial angle (FTA): mild, moderate, severe and profound). The mean measurements in each group were calculated and compared within each group. The femoral shaft showed medially bowed curvature (femoral bowing) of approximately 2° in the young normal group, which shifted to lateral bowing with age. However, OA knees showed larger lateral bowing with OA grade, which might reduce the condylar-shaft angle and subsequently shifted the mechanical axis medially. Progression of mild to moderate OA might be associated with a decreasing condylar-shaft angle (femoral condylar orientation) and widening condylar-plateau angle (joint space narrowing) rather than decreasing tibial plateau flattering. Steeping of the tibial plateau inclination due to increasing tibial plateau shift (tibial plateau compression) rather than medial tibial bowing might be the main contributor to worsening of varus deformity in knees with severe and profound OA. This cross-sectional study might provide the possibility of OA initiation and progression. The lateral curvature of the femoral shaft associated with aging may contribute to the initiation of varus-type OA of the knee. These changes in the femur may be followed by secondary signs of OA progression including varus femoral condylar orientation, medial joint space narrowing, and tibial plateau compression. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  5. Reliability analysis for radiographic measures of lumbar lordosis in adult scoliosis: a case–control study comparing 6 methods

    Science.gov (United States)

    Hong, Jae Young; Modi, Hitesh N.; Hur, Chang Yong; Song, Hae Ryong; Park, Jong Hoon

    2010-01-01

    Several methods are used to measure lumbar lordosis. In adult scoliosis patients, the measurement is difficult due to degenerative changes in the vertebral endplate as well as the coronal and sagittal deformity. We did the observational study with three examiners to determine the reliability of six methods for measuring the global lumbar lordosis in adult scoliosis patients. Ninety lateral lumbar radiographs were collected for the study. The radiographs were divided into normal (Cobb lordosis measurement decreased with increasing severity of scoliosis. In Cobb L1–S1, centroid and posterior tangent L1–S1 methods, the ICCs were relatively lower in the high-grade scoliosis group (≥0.60). And, the mean absolute difference (MAD) in these methods was high in the high-grade scoliosis group (≤7.17°). However, in the Cobb L1–L5 and posterior tangent L1–L5 method, the ICCs were ≥0.86 in all groups. And, in the TRALL method, the ICCs were ≥0.76 in all groups. In addition, in the Cobb L1–L5 and posterior tangent L1–L5 method, the MAD was ≤3.63°. And, in the TRALL method, the MAD was ≤3.84° in all groups. We concluded that the Cobb L1–L5 and the posterior tangent L1–L5 methods are reliable methods for measuring the global lumbar lordosis in adult scoliosis. And the TRALL method is more reliable method than other methods which include the L5–S1 joint in lordosis measurement. PMID:20437183

  6. A radiographic analysis of the contribution of hallux valgus interphalangeus to the total valgus deformity of the hallux.

    Science.gov (United States)

    Strydom, Andrew; Saragas, Nikiforos Pandelis; Ferrao, Paulo Norberto Faria

    2017-03-01

    The hallux valgus interphalangeus (HVI) deformity is described as rare, but improved outcomes in hallux valgus (HV) surgery is associated with its surgical correction via an Akin osteotomy. The hypothesis of this study is that HVI is common and makes a significant contribution to the total valgus deformity of the hallux (TVDH). 285 pre-operative foot radiographs (193 with HV, 92 non-HV), utilising standardised radiographic and measurement techniques, were analysed retrospectively. The hallux valgus angle (HVA), intermetatarsal angle (IMA), interphalangeal angle (IPA) and distal metatarsal articular angle (DMAA) were measured. The TVDH was calculated as the sum of the HVA and IPA. 163 (57.2%) of the study population were Caucasian, 119 (41.8%) African and 3 Indian (1.0%). 236 (82.8%) of the population was female. There was a statistically significant difference in the proportion of abnormal IPA in the Caucasian population 112 (68.7%) compared to the proportion of abnormal IPA in the African population 64 (53.8%), p=0.01. The average contribution of the IPA to the TVDH across the whole study population was a mean (SD) of 37.9% (21.2). The average contribution of IPA to TVDH was greater in feet without HV (58.0%) when compared to feet with HV (28.3%). HVI is common, particularly in Caucasians (p=0.01) and makes a significant contribution to the TVDH (p<0.01). The contribution to the TVDH is more significant in mild HV. There is an inverse relationship between the IPA and other angular measurements in the foot. HVI is a common entity. The significant contribution of the IPA to the TVDH dictates that HVI must be incorporated in management algorithms. The TVDH should replace the isolated concepts of HV and HVI. Level III, retrospective cohort. Copyright © 2016 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  7. Agreement between radiographic and photographic trabecular patterns

    International Nuclear Information System (INIS)

    Korstjens, C.M.; Geraets, W.G.M.; Stelt, P.F. van der; Spruijt, R.J.; Mosekilde, L.

    1998-01-01

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach's α>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  8. Agreement between radiographic and photographic trabecular patterns

    Energy Technology Data Exchange (ETDEWEB)

    Korstjens, C.M.; Geraets, W.G.M.; Stelt, P.F. van der [Dept. of Oral Radiology, Academic Centre for Dentistry, Amsterdam (Netherlands); Spruijt, R.J. [Div. of Psychosocial Research and Epidemiology, Netherlands Cancer Inst., Amsterdam (Netherlands); Mosekilde, L. [Dept. of Cell Biology, Univ. of Aarhus (Denmark)

    1998-11-01

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach`s {alpha}>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  9. Radiographic manifestations of hypochondroplasia

    Energy Technology Data Exchange (ETDEWEB)

    Heselson, N G; Cremin, B J [Groote Schuur Hospital, Cape Town (South Africa); Beighton, P

    1979-01-01

    Hypochrondroplasia is an inherited skeletal dysplasia that resembles achondroplasia in mild degree. Radiographic manifestations encountered in 12 affected individuals in South Africa include slight shortening of all segments of the tubular bones, moderate caudal diminution of the lumbar interpedicular distances, increased lumbar lordosis with cacral tilt and distal prolongation of the fibular. Hypochondroplasia can be distinguished from other osteochondrodystrophies such as achondroplasia, pseudo-achondroplasia and metaphyseal chondroplasia by the recognition of it clinical and radiographic manifestations.

  10. Proteomic analysis of cold stress responses in tobacco seedlings ...

    African Journals Online (AJOL)

    Cold stress is one of the major abiotic stresses limiting the productivity and the geographical distribution of many important crops. To gain a better understanding of cold stress responses in tobacco (Nicotiana tabacum), we carried out a comparative proteomic analysis. Five-week-old tobacco seedlings were treated at 4°C ...

  11. Finite element stress analysis of brick-mortar masonry under ...

    African Journals Online (AJOL)

    Stress analysis of a brick-mortar couplet as a substitute for brick wall structure has been performed by finite element method, and algorithm for determining the element stiffness matrix for a plane stress problem using the displacement approach was developed. The nodal displacements were derived for the stress in each ...

  12. Hip2Norm: an object-oriented cross-platform program for 3D analysis of hip joint morphology using 2D pelvic radiographs.

    Science.gov (United States)

    Zheng, G; Tannast, M; Anderegg, C; Siebenrock, K A; Langlotz, F

    2007-07-01

    We developed an object-oriented cross-platform program to perform three-dimensional (3D) analysis of hip joint morphology using two-dimensional (2D) anteroposterior (AP) pelvic radiographs. Landmarks extracted from 2D AP pelvic radiographs and optionally an additional lateral pelvic X-ray were combined with a cone beam projection model to reconstruct 3D hip joints. Since individual pelvic orientation can vary considerably, a method for standardizing pelvic orientation was implemented to determine the absolute tilt/rotation. The evaluation of anatomically morphologic differences was achieved by reconstructing the projected acetabular rim and the measured hip parameters as if obtained in a standardized neutral orientation. The program had been successfully used to interactively objectify acetabular version in hips with femoro-acetabular impingement or developmental dysplasia. Hip(2)Norm is written in object-oriented programming language C++ using cross-platform software Qt (TrollTech, Oslo, Norway) for graphical user interface (GUI) and is transportable to any platform.

  13. Radiographic examination of the equine foot

    International Nuclear Information System (INIS)

    Park, R.D.

    1989-01-01

    A complete radiographic examination of the equine foot consists of properly exposed, processed, and positioned radiographs. For radiographic interpretation, in addition to knowing radiographic signs of disease, a knowledge of normal radiographic anatomy and possible insignificant anatomic variations is necessary

  14. Factor analysis for exercise stress radionuclide ventriculography

    International Nuclear Information System (INIS)

    Hirota, Kazuyoshi; Yasuda, Mitsutaka; Oku, Hisao; Ikuno, Yoshiyasu; Takeuchi, Kazuhide; Takeda, Tadanao; Ochi, Hironobu

    1987-01-01

    Using factor analysis, a new image processing in exercise stress radionuclide ventriculography, changes in factors associated with exercise were evaluated in 14 patients with angina pectoris or old myocardial infarction. The patients were imaged in the left anterior oblique projection, and three factor images were presented on a color coded scale. Abnormal factors (AF) were observed in 6 patients before exercise, 13 during exercise, and 4 after exercise. In 7 patients, the occurrence of AF was associated with exercise. Five of them became free from AF after exercise. Three patients showing AF before exercise had aggravation of AF during exercise. Overall, the occurrence or aggravation of AF was associated with exercise in ten (71 %) of the patients. The other three patients, however, had disappearance of AF during exercise. In the last patient, none of the AF was observed throughout the study. In view of a high incidence of AF associated with exercise, the factor analysis may have the potential in evaluating cardiac reverse from the viewpoint of left ventricular wall motion abnormality. (Namekawa, K.)

  15. Risk of losing remission, low disease activity or radiographic progression in case of bDMARD discontinuation or tapering in rheumatoid arthritis: systematic analysis of the literature and meta-analysis.

    Science.gov (United States)

    Henaux, Sophie; Ruyssen-Witrand, Adeline; Cantagrel, Alain; Barnetche, Thomas; Fautrel, Bruno; Filippi, Nathalie; Lukas, Cédric; Raffeiner, Bernd; Rossini, Maurizio; Degboé, Yannick; Constantin, Arnaud

    2018-04-01

    To assess the risk of losing remission, low disease activity (LDA) or radiographic progression in the case of (1) discontinuing or (2) tapering doses of biological disease-modifying antirheumatic drugs (bDMARDs) compared with continuation of the initial treatment regimen in rheumatoid arthritis (RA) patients with remission or LDA. A systematic literature analysis was carried out through May 2017 on the PubMed, Embase, Cochrane and international congress databases, selecting controlled trials comparing bDMARDs discontinuation/tapering versus continuation in RA patients with remission or LDA. The meta-analysis assessed the risk ratio (RR) and 95% CI of losing remission or LDA and the risk of radiographic progression after (1) discontinuing and (2) tapering doses of bDMARDs versus continuing the initial treatment. The meta-analysis comparing bDMARDs discontinuation versus continuation performed on nine trials showed an increased risk of losing remission (RR (95% CI)=1.97(1.43 to 2.73), P<0.0001) or LDA (RR (95% CI)=2.24(1.52 to 3.30), P<0.0001) and an increased risk of radiographic progression (RR (95% CI)=1.09(1.02 to 1.17), P=0.01) in case of bDMARD discontinuation. The meta-analysis comparing bDMARDs tapering versus continuation performed on 11 trials showed an increased risk of losing remission (RR (95% CI)=1.23(1.06 to 1.42), P=0.006) but no increased risk of losing LDA (RR (95% CI)=1.02 (0.85 to 1.23), P=0.81) nor any increased risk of radiographic progression (RR (95% CI)=1.09(0.94 to 1.26), P=0.26) in case of bDMARD tapering. Discontinuation of bDMARDs leads to an increased risk of losing remission or LDA and radiographic progression, while tapering doses of bDMARDs does not increase the risk of relapse (LDA) or radiographic progression, even though there is an increased risk of losing remission. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted

  16. Magnetic resonance analysis of loaded meniscus deformation: a novel technique comparing participants with and without radiographic knee osteoarthritis

    Energy Technology Data Exchange (ETDEWEB)

    MacLeod, Toran D. [California State University, Department of Physical Therapy, Sacramento, CA (United States); Subburaj, Karupppasamy; Wu, Samuel; Kumar, Deepak; Wyatt, Cory; Souza, Richard B. [University of California, Department of Radiology and Biomedical Imaging, Musculoskeletal and Quantitative Imaging Research Group, San Francisco, CA (United States)

    2015-01-15

    To establish a novel method of quantifying meniscal deformation using loaded MRI. More specifically, the goals were to evaluate the (1) accuracy, (2) inter-rater reliability, (3) intra-rater reliability, and (4) scan-rescan reliability. The secondary purpose of this experiment was to evaluate group differences in meniscal deformation in participants with and without radiographic knee OA. Weight-bearing 3-T MRIs of the knee in full extension and 30 of flexion were processed to create 3D models of meniscal deformation. Accuracy was assessed using a custom-designed phantom. Twenty-one participants either with or without signs of OA were evaluated, and another six participants (14 knees, one subject was scanned twice) underwent repeated imaging to assess scan-rescan reproducibility. Intraclass correlation coefficient (ICC), root-mean squared error (RMSE), and root-mean-square percent coefficient-of-variation (RMS%CV) analyses were performed. Exploratory comparisons were made between those with and without OA to evaluate potential group differences. All variables were found to be accurate with RMSE ranging from 0.08 to 0.35 mm and 5.99 to 14.63 mm{sup 2}. Reproducibility of peak anterior-posterior meniscal deformation was excellent (ICC > 0.821; p < 0.013) with RMS%CV for intra-rater ranging from 0.06 to 1.53 % and 0.17 to 1.97 %, inter-rater ranging from 0.10 to 7.20 % and 3.95 to 18.53 %, and scan-rescan reliability ranging from 1.531 to 7.890 % and 4.894 to 9.142 %, for distance and area metric, respectively. Participants with OA were found to have significantly greater anterior horn movement of both the medial (p = 0.039) and lateral meniscus (p = 0.015), and smaller flexed medial meniscus outer area (p = 0.048) when compared to controls. MRI-based variables of meniscus deformation were found to be valid in participants with and without OA. Significant differences were found between those with and without radiographic OA; further study is warranted. (orig.)

  17. Australian rural radiographers' perspectives on disclosure of their radiographic opinion to patients

    International Nuclear Information System (INIS)

    Squibb, Kathryn; Bull, Rosalind M.; Smith, Anthony; Dalton, Lisa

    2015-01-01

    The role of Australian rural radiographers in radiographic interpretation, communication and disclosure of their radiographic opinion with a specific focus on plain film radiography was examined in a two phase, exploratory interpretive study. Data were collected using questionnaires and interviews and analysed thematically. This reports one of the key themes identified in the thematic data analysis. ‘Disclosure of Radiographic Opinion to Patients’ comprises the three interrelated sub-themes Acting Ethically, Selective Disclosure and Filtered Truth. It is wholly concerned with the ways in which rural radiographers choose to disclose their radiographic opinion to patients. Without a clear picture of where they stand medico-legally, rural radiographers draw on experience and a strong ethical framework as the basis for these complex decisions. Rural radiographers frame their disclosures to patients in a manner that is governed by the diagnostic, therapeutic and emotional impact the information disclosed may have on the patient. Disclosure to patients was found to be selective, often diagnostically vague and ethically filtered

  18. Stress analysis on a PWR pressure vessel support structure

    International Nuclear Information System (INIS)

    Cruz, J.R.B.; Mattar Neto, M.; Jesus Miranda, C.A. de.

    1992-01-01

    The paper presents the stress analysis of a research PWR vessel support structure. Different geometries and thermal boundary conditions are evaluated. The finite element analysis is performed using ANSYS program. The ASME Section III criteria are applied for the stress verification and the following points are discussed: stress classification and linearization; jurisdictional boundary between ASME Subsection NB (Class 1 Components) and Subsection NF (Component Supports). (author)

  19. An in vitro radiographic analysis of the density of dental luting cements as measured by CCD-based digital radiography.

    Science.gov (United States)

    Antonijevic, Djordje; Jevremovic, Danimir; Jovanovic, Svetlana; Obradovic-Djuricic, Kosovka

    2012-05-01

    According to the ISO, the radiopacity of luting cements should be equal to or greater than that of aluminum. The aim of this in vitro study was to determine the radiopacity of 13 commercially available dental luting cements and compare them with human enamel and dentin. Five classes of luting cements were evaluated: zinc phosphate (Cegal N and Harvard Zinc Phosphate), zinc polycarboxylate (Harvard Polycarboxylate and Hoffmann's Carboxylate), glass ionomers (Ketac Cem Easymix, Ketac Cem Radiopaque, and Fuji I), resin-modified glass ionomer (Rely X Luting), and resin cements (Multilink Automix, Variolink II, Speed CEM, Rely X Unicem Automix, and three shades of Variolink Veneer). Tooth slices served as controls. Five specimens of each material measuring 8 mm in diameter and 1 mm thick were prepared and radiographed alongside tooth slices and an aluminum stepwedge using a Trophy RVG sensor. The radiopacity values were expressed in mm Al and analyzed by the ANOVA and Tukey tests (P cements examined except Variolink Veneer had significantly higher radiopacities than that of dentin. Rely X Unicem Automix, glass ionomer, and resin-modified glass-ionomer cements demonstrated radiopacities that were not significantly different with respect to enamel. Zinc phosphate, zinc polycarboxylate, and three of the resin cements presented radiopacity values that were significantly greater than that of enamel. Almost all the investigated materials presented an acceptable radiopacity. Radiopacity of dental cements seems to depend more on the presence of elements with high atomic numbers than on the type of the material.

  20. Stress analysis of HLW containers. Compas project

    International Nuclear Information System (INIS)

    1989-01-01

    This document reports the work carried out for the Compas project which looked at the performance of various computer codes in a selected benchmark exercise. This exercise consisted of several analyses on simplified models which have features typical of HLW containers. These analyses comprise two groups; one related to thick walled, stressed shell overpacks, the other related to thin walled, supported shell overpacks with a lead filler. The first set of analyses looked at an elastic-plastic behaviour and large deformation of a cylinder representative of the main body of thick walled containers). The second set looked at creep behaviour of the lead filler, and the shape the base of thin walled containers will take up, after hundreds of years in the repository. On the thick walled analyses with the cylinder subject to an external pressure all the codes gave consistent results in the elastic region and there is good agreement in the yield pressures. Once in the plastic region there is more divergence in the results although a consistent trend is predicted. One of the analyses predicted a non-axisymmetric mode of deformation as would be expected in reality. Fewer results were received for the creep analysis, however the transient creep results showed consistency, and were bounded by the final-state results

  1. Radiographic findings of degeneration in cervical spines of middle-aged soccer players

    International Nuclear Information System (INIS)

    Kurosawa, Hideki; Yamakoshi, Ken-ichi

    1991-01-01

    Twelve amateur veteran soccer players (average age 40.1 ± 5.4 years), who began playing in their teens and who were admitted with symptoms most likely to be related to cervical spondylosis, were examined by cervical radiography. Abnormal radiographic findings included: calcification of anterior longitudinal ligament (25%), anterior (75%) and posterior vertebral spurs (75%), ossicle between spinous processes (75%), calcification of nuchal ligament (Barsony) (58%), ossicle on spinous process (25%), and bony spur of Luschka's joints (83%). It was shown in the stress distribution by finite element method analysis that the stress in heading the ball was applied mainly to the lower parts of the cervical spine. The results of this analysis also corresponded well with some of the radiographic findings. (orig.)

  2. Radiographic findings of degeneration in cervical spines of middle-aged soccer players

    Energy Technology Data Exchange (ETDEWEB)

    Kurosawa, Hideki; Yamakoshi, Ken-ichi (Hokkaido Univ., Sapporo (Japan). Research Inst. of Applied Electricity); Yamanoi, Takahiro (Hokkaigakuen Univ., Sapporo (Japan))

    1991-08-01

    Twelve amateur veteran soccer players (average age 40.1 {+-} 5.4 years), who began playing in their teens and who were admitted with symptoms most likely to be related to cervical spondylosis, were examined by cervical radiography. Abnormal radiographic findings included: calcification of anterior longitudinal ligament (25%), anterior (75%) and posterior vertebral spurs (75%), ossicle between spinous processes (75%), calcification of nuchal ligament (Barsony) (58%), ossicle on spinous process (25%), and bony spur of Luschka's joints (83%). It was shown in the stress distribution by finite element method analysis that the stress in heading the ball was applied mainly to the lower parts of the cervical spine. The results of this analysis also corresponded well with some of the radiographic findings. (orig.).

  3. Local stress analysis in devices by FIB

    NARCIS (Netherlands)

    Kregting, R.; Gielen, A.W.J.; Driel, W. van; Alkemade, P.; Miro, H.; Kamminga, J.-D.

    2010-01-01

    Intrinsic stresses in bondpads may lead to early failure of IC's. In order to determine the intrinsic stresses in semiconductor structures, a new procedure is set up. This procedure is a combined experimental/numerical approach which consists of the following steps: First, a conductive gold layer

  4. Analysis of stress-strain relationships in silicon ribbon

    Science.gov (United States)

    Dillon, O. W., Jr.

    1984-01-01

    An analysis of stress-strain relationships in silicon ribbon is presented. A model to present entire process, dynamical Transit Analysis is developed. It is found that knowledge of past-strain history is significant in modeling activities.

  5. Stress Analysis in Polymeric Coating Layer Deposited on Rigid Substrate

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Soon Lee [Korea University of Technology and Education, School of Mechatronics Engineering, Chonan (Korea, Republic of)

    2015-08-15

    This paper presents an analysis of thermal stress induced along the interface between a polymeric coating layer and a steel substrate as a result of uniform temperature change. The epoxy layer is assumed to be a linear viscoelastic material and to be theromorheologically simple. The viscoelastic boundary element method is employed to investigate the behavior of interface stresses. The numerical results exhibit relaxation of interface stresses and large stress gradients, which are observed in the vicinity of the free surface. Since the exceedingly large stresses cannot be borne by the polymeric coating layer, local cracking or delamination can occur at the interface corner.

  6. Trends in hip dysplasia control: analysis of radiographs submitted to the orthopedic foundation for animals, 1974 to 1984

    International Nuclear Information System (INIS)

    Corley, E.A.; Hogan, P.M.

    1985-01-01

    From 1974 through 1984, the Orthopedic Foundation for Animals evaluated 143,218 radiographic submissions representing 151 breeds of dogs. All breeds from which there were 35 or more evaluations had some frequency of dysplasia. Seventy breeds, each with over 100 submissions, were tabulated and ranked according to frequency of hip dysplasia. Frequency of dysplasia varied from 0.6% in the Borzoi to 46.9% in the Saint Bernard. These data were compared with data obtained earlier (1966 to 1973) on evaluations in 38 breeds for changes in frequency. There was significant (P less than 0.05) reduction in frequency of dysplasia in 27 breeds, a significant (P less than 0.05) increase in frequency in only 1 breed (German Shorthaired Pointer), and no significant change in frequency in 10 breeds. The median significant decrease was 22.4%, and the range was from 3.1% in the Chesapeake Bay Retriever to 48.7% in the Keeshond. The reduction in frequency of hip dysplasia demonstrated the value of a control program. There were 5 breeds with a significant (P less than 0.05) decrease in frequency of dysplasia that had over 5,000 evaluations from 1974 to 1984. The decreases in frequency were independent of changes in American Kennel Club registrations for these breeds (a dramatic decline in registrations for the German Shepherd Dog and Old English Sheepdog, and a dramatic increase for the Rottweiler, Golden Retriever, and Labrador Retriever). Frequency regressed linearly in the German Shepherd Dog and Old English Sheepdog, but regressed nonlinearly in the other 3 breeds. The percentage reduction in frequency from the base frequency (1966 to 1973) for these breeds was 17.5% for the German Shepherd Dog, 23.1% for the Old English Sheepdog, 9.1% for the Rottweiler, 10.1% for the Golden Retriever, and 6.8% for the Labrador Retriever

  7. Radiographic aspects of xeroradiography

    International Nuclear Information System (INIS)

    Rao, G.U.V.; Fatouros, P.P.

    1980-01-01

    The quality of a conventional radiographic image can be characterized in terms of five basic parameters; density, contrast, latitude, resolution and noise. Since xeroradiographic images exhibit very limited broad area contrasts, and image formation is predominantly due to edge enhancement, a straightforward description of image quality using the same five parameters is not adequate. A detailed study was made of the radiographic aspects of xeroradiography with special reference to mammography, and a summary of major findings to date with appropriate references to published papers is presented

  8. Analysis of pipe stress using CAESAR II code

    International Nuclear Information System (INIS)

    Sitandung, Y.B.; Bandriyana, B.

    2002-01-01

    Analysis of this piping stress with the purpose of knowing stress distribution piping system in order to determine pipe supports configuration. As an example of analysis, Gas Exchanger to Warm Separator Line was chosen with, input data was firstly prepared in a document, i.e. piping analysis specification that its content named as pipe characteristics, material properties, operation conditions, guide equipment's and so on. Analysis result such as stress, load, displacement and the use support type were verified based on requirements in the code, standard, and regularities were suitable with piping system condition analyzed. As the proof that piping system is in safety condition, it can be indicated from analysis results (actual loads) which still under allowable load. From the analysis steps that have been done CAESAR II code fulfill requirements to be used as a tool of piping stress analysis as well as nuclear and non nuclear installation piping system

  9. Problems of stress analysis of fuelling machine head components

    International Nuclear Information System (INIS)

    Mathur, D.D.

    1975-01-01

    The problem of stress analysis of fuelling machine head components are discussed. To fulfil the functional requirements, the components are required to have certain shapes where stress problems cannot be matched to a catalogue of pre-determined solutions. The areas where complex systems of loading due to hydrostatic pressure, weight, moments and temperature gradients coupled with the intricate shapes of the components make it difficult to arrive at satisfactory solutions. Particularly, the analysis requirements of the magazine housing, end cover, gravloc clamps and centre support are highlighted. An experimental stress analysis programme together with a theoretical finite element analysis is perhaps the answer. (author)

  10. Stress analysis for nuclear power plant components

    International Nuclear Information System (INIS)

    Mueller, R.A.

    1981-09-01

    The general procedure for a meaningful stress evaluation will be outlined. The extremely aggravated conditions prevailing at elevated temperatures, at which creep effects can no longer be neglected, will also be touched upon briefly. (E.G.) [pt

  11. The stress and strain analysis research of class 1 eqnipments

    International Nuclear Information System (INIS)

    Ye Yuanwu; Tang Long; Wang Yueying; Qi Min; Yu Huajin

    2008-01-01

    The class 1 equipment is very important in the nuclear device, in the design and testing process required to carry out their stress and strain analysis, so as to ensure their safety. There are two ways to get stress and strain analysis of the class 1 equipment, the theoretical and experimental methods. Through theoretical method can get the stress and strain of the class 1 equipment, so as to provide a basis for the design of the equipment; through the experimental method to verify the accuracy of the theoretical methods and provide a basis for the safety assessment of the equipment. The main ressel of CEFR (China Experimental Fast Reactor) is the class 1 equipment. In this paper, according to the stress and strain analysis research of CEFR main vessel, the theories and expperimental methods of nuclear class 1 equipments stress and strain analysis has been described. (authors)

  12. DEVELOPMENT OF COILED TUBING STRESS ANALYSIS

    Directory of Open Access Journals (Sweden)

    Davorin Matanović

    1998-12-01

    Full Text Available The use of coiled tubing is increasing rapidly with drilling of horizontal wells. To satisfy all requirements (larger mechanical stresses, larger fluid capacities the production of larger sizes and better material qualities was developed. Stresses due to axial forces and pressures that coiled tubing is subjected are close to its performance limits. So it is really important to know and understand the behaviour of coiled tubing to avoid its break, burst or collapse in the well.

  13. Initial stress and nonlinear material behavior in patient-specific AAA wall stress analysis

    NARCIS (Netherlands)

    Speelman, L.; Bosboom, E.M.H.; Schurink, G.W.H.; Buth, J.; Breeuwer, M.; Jacobs, M.J.; Vosse, van de F.N.

    2009-01-01

    Rupture risk estimation of abdominal aortic aneurysms (AAA) is currently based on the maximum diameter of the AAA. A more critical approach is based on AAA wall stress analysis. For that, in most cases, the AAA geometry is obtained from CT-data and treated as a stress free geometry. However, during

  14. Weight bearing cone beam CT scan versus gravity stress radiography for analysis of supination external rotation injuries of the ankle.

    Science.gov (United States)

    Marzo, John M; Kluczynski, Melissa A; Clyde, Corey; Anders, Mark J; Mutty, Christopher E; Ritter, Christopher A

    2017-12-01

    For AO 44-B2 ankle fractures of uncertain stability, the current diagnostic standard is to obtain a gravity stress radiograph, but some have advocated for the use of weight-bearing radiographs. The primary aim was to compare measures of medial clear space (MCS) on weight-bearing cone beam computed tomography (CBCT) scans versus gravity stress radiographs for determining the state of stability of ankle fractures classified as AO SER 44-B2 or Weber B. The secondary aim was to evaluate the details offered by CBCT scans with respect to other findings that may be relevant to patient care. Nine patients were enrolled in this cross-sectional study between April 2016 and February 2017 if they had an AO SER 44-B2 fracture of uncertain stability, had a gravity stress radiograph, and were able to undergo CT scan within seven days. The width of the MCS was measured at the level of the talar dome on all radiographs and at the mid coronal slice on CT. Wilcoxon signed-ranks tests were used to compare MCS between initial radiographs, gravity stress radiographs and weight-bearing CBCT scans. MCS on weight-bearing CBCT scan (1.41±0.41 mm) was significantly less than standard radiographs (3.28±1.63 mm, P=0.004) and gravity stress radiographs (5.82±1.93 mm, P=0.02). There was no statistically significant difference in MCS measured on standard radiographs versus gravity stress radiographs (P=0.11). Detailed review of the multiplanar CT images revealed less than perfect anatomical reduction of the fractures, with residual fibular shortening, posterior displacement, and fracture fragments in the incisura as typical findings. Similar to weight-bearing radiographs, weight-bearing CBCT scan can predict stability of AO 44-B2 ankle fractures by showing restoration of the MCS, and might be used to indicate patients for non-operative treatment. None of the fractures imaged in this study were perfectly reduced however, and further clinical research is necessary to determine if any of the

  15. Finite Element Residual Stress Analysis of Planetary Gear Tooth

    Directory of Open Access Journals (Sweden)

    Jungang Wang

    2013-01-01

    Full Text Available A method to simulate residual stress field of planetary gear is proposed. In this method, the finite element model of planetary gear is established and divided to tooth zone and profile zone, whose different temperature field is set. The gear's residual stress simulation is realized by the thermal compression stress generated by the temperature difference. Based on the simulation, the finite element model of planetary gear train is established, the dynamic meshing process is simulated, and influence of residual stress on equivalent stress of addendum, pitch circle, and dedendum of internal and external meshing planetary gear tooth profile is analyzed, according to non-linear contact theory, thermodynamic theory, and finite element theory. The results show that the equivalent stresses of planetary gear at both meshing and nonmeshing surface are significantly and differently reduced by residual stress. The study benefits fatigue cracking analysis and dynamic optimization design of planetary gear train.

  16. PIPE STRESS and VERPIP codes for stress analysis and verifications of PEC reactor piping

    International Nuclear Information System (INIS)

    Cesari, F.; Ferranti, P.; Gasparrini, M.; Labanti, L.

    1975-01-01

    To design LMFBR piping systems following ASME Sct. III requirements unusual flexibility computer codes are to be adopted to consider piping and its guard-tube. For this purpose PIPE STRESS code previously prepared by Southern-Service, has been modified. Some subroutine for detailed stress analysis and principal stress calculations on all the sections of piping have been written and fitted in the code. Plotter can also be used. VERPIP code for automatic verifications of piping as class 1 Sct. III prescriptions has been also prepared. The results of PIPE STRESS and VERPIP codes application to PEC piping are in section III of this report

  17. Probabilistic analysis of structures involving random stress-strain behavior

    Science.gov (United States)

    Millwater, H. R.; Thacker, B. H.; Harren, S. V.

    1991-01-01

    The present methodology for analysis of structures with random stress strain behavior characterizes the uniaxial stress-strain curve in terms of (1) elastic modulus, (2) engineering stress at initial yield, (3) initial plastic-hardening slope, (4) engineering stress at point of ultimate load, and (5) engineering strain at point of ultimate load. The methodology is incorporated into the Numerical Evaluation of Stochastic Structures Under Stress code for probabilistic structural analysis. The illustrative problem of a thick cylinder under internal pressure, where both the internal pressure and the stress-strain curve are random, is addressed by means of the code. The response value is the cumulative distribution function of the equivalent plastic strain at the inner radius.

  18. Nondestructive examination - radiographic techniques

    International Nuclear Information System (INIS)

    Maier, H.J.

    1980-01-01

    First the basic principles of radiography are to be treated, especially the different radiation sources (X-ray, gamma-ray, neutrons, heat). In the second part those radiographic methods are shown, which are in common use for technical purposes, especially under the aspect of flaw recognition. (orig./RW)

  19. Matching hand radiographs

    NARCIS (Netherlands)

    Kauffman, J.A.; Slump, Cornelis H.; Bernelot Moens, H.J.

    2005-01-01

    Biometric verification and identification methods of medical images can be used to find possible inconsistencies in patient records. Such methods may also be useful for forensic research. In this work we present a method for identifying patients by their hand radiographs. We use active appearance

  20. Stabilized radiographic scanning agent

    International Nuclear Information System (INIS)

    Fawzi, M.B.

    1979-01-01

    A stable composition useful in preparation of technetium-99m-based radiographic scanning agents has been developed. The composition contains a stabilizing amount of gentisate stabilizer selected from gentisic acid and its soluble pharmaceutically-acceptable salts and esthers. (E.G.)

  1. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Tofe, A.J.

    1976-01-01

    A stable radiographic scanning agent on a sup(99m)Tc basis has been developed. The substance contains a pertechnetate reduction agent, tin(II)-chloride, chromium(II)-chloride, or iron(II)-sulphate, as well as an organospecific carrier and ascorbic acid or a pharmacologically admissible salt or ester of ascorbic acid. (VJ) [de

  2. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  3. Radiographic evaluation of hallux valgus

    International Nuclear Information System (INIS)

    Richardson, M.L.; Hansen, S.T.; Kilcoyne, R.F.

    1987-01-01

    This paper presents the common preoperative and postoperative findings in hallux valgus, a common foot disorder of multiple etiologies, which can lead to significant foot pain and deformity. Little has been published in radiologic literature about the proper initial radiographic workup and the postoperative follow-up of this very common and very treatable cause of foot pain. Besides the primary findings of varus angulation of the first metatarsal and valgus angulation of the great toe, one may also see dorsal slaying of the first metatarsal head. As increased weight is borne by the central metatarsals, they may develop hyperostosis and stress fractures. Angular deformities of the hallux sesamoid joint and lesser toes may also be seen

  4. Thermographic Analysis of Stress Distribution in Welded Joints

    Directory of Open Access Journals (Sweden)

    Domazet Ž.

    2010-06-01

    Full Text Available The fatigue life prediction of welded joints based on S-N curves in conjunction with nominal stresses generally is not reliable. Stress distribution in welded area affected by geometrical inhomogeneity, irregular welded surface and weld toe radius is quite complex, so the local (structural stress concept is accepted in recent papers. The aim of this paper is to determine the stress distribution in plate type aluminum welded joints, to analyze the reliability of TSA (Thermal Stress Analysis in this kind of investigations, and to obtain numerical values for stress concentration factors for practical use. Stress distribution in aluminum butt and fillet welded joints is determined by using the three different methods: strain gauges measurement, thermal stress analysis and FEM. Obtained results show good agreement - the TSA mutually confirmed the FEM model and stresses measured by strain gauges. According to obtained results, it may be stated that TSA, as a relatively new measurement technique may in the future become a standard tool for the experimental investigation of stress concentration and fatigue in welded joints that can help to develop more accurate numerical tools for fatigue life prediction.

  5. Thermographic Analysis of Stress Distribution in Welded Joints

    Science.gov (United States)

    Piršić, T.; Krstulović Opara, L.; Domazet, Ž.

    2010-06-01

    The fatigue life prediction of welded joints based on S-N curves in conjunction with nominal stresses generally is not reliable. Stress distribution in welded area affected by geometrical inhomogeneity, irregular welded surface and weld toe radius is quite complex, so the local (structural) stress concept is accepted in recent papers. The aim of this paper is to determine the stress distribution in plate type aluminum welded joints, to analyze the reliability of TSA (Thermal Stress Analysis) in this kind of investigations, and to obtain numerical values for stress concentration factors for practical use. Stress distribution in aluminum butt and fillet welded joints is determined by using the three different methods: strain gauges measurement, thermal stress analysis and FEM. Obtained results show good agreement - the TSA mutually confirmed the FEM model and stresses measured by strain gauges. According to obtained results, it may be stated that TSA, as a relatively new measurement technique may in the future become a standard tool for the experimental investigation of stress concentration and fatigue in welded joints that can help to develop more accurate numerical tools for fatigue life prediction.

  6. Ceramic ball grid array package stress analysis

    Science.gov (United States)

    Badri, S. H. B. S.; Aziz, M. H. A.; Ong, N. R.; Sauli, Z.; Alcain, J. B.; Retnasamy, V.

    2017-09-01

    The ball grid array (BGA), a form of chip scale package (CSP), was developed as one of the most advanced surface mount devices, which may be assembled by an ordinary surface ball bumps are used instead of plated nickel and gold (Ni/Au) bumps. Assembly and reliability of the BGA's printed circuit board (PCB), which is soldered by conventional surface mount technology is considered in this study. The Ceramic Ball Grid Array (CBGA) is a rectangular ceramic package or square-shaped that will use the solder ball for external electrical connections instead of leads or wire for connections. The solder balls will be arranged in an array or grid at the bottom of the ceramic package body. In this study, ANSYS software is used to investigate the stress on the package for 2 balls and 4 balls of the CBGA package with the various force range of 1-3 Newton applied to the top of the die, top of the substrate and side of the substrate. The highest maximum stress was analyzed and the maximum equivalent stress was observed on the solder ball and the die. From the simulation result, the CBGA package with less solder balls experience higher stress compared to the package with many solder balls. Therefore, less number of solder ball on the CBGA package results higher stress and critically affect the reliability of the solder balls itself, substrate and die which can lead to the solder crack and also die crack.

  7. SLAC divertor channel entrance thermal stress analysis

    International Nuclear Information System (INIS)

    Johnson, G.L.; Stein, W.; Lu, S.C.; Riddle, R.A.

    1985-01-01

    X-ray beams emerging from the new SLAC electron-positron storage ring (PEP) impinge on the entrance to tangential divertor channels causing highly localized heating in the channel structure. Analyses were completed to determine the temperatures and thermally-induced stresses due to this heating. These parts are cooled with water flowing axially over them at 30 0 C. The current design and operating conditions should result in the entrance to the new divertor channel operating at a peak temperature of 123 0 C with a peak thermal stress at 91% of yield. Any micro-cracks that form due to thermally-induced stresses should not propagate to the coolant wall nor form a path for the coolant to leak into the storage ring vacuum. 34 figs., 4 tabs

  8. Analysis of primary teacher stress' sources

    Directory of Open Access Journals (Sweden)

    Katja Depolli Steiner

    2011-12-01

    Full Text Available Teachers are subject to many different work stressors. This study focused on differences in intensity and frequency of potential stressors facing primary schoolteachers and set the goal to identify the most important sources of teacher stress in primary school. The study included 242 primary schoolteachers from different parts of Slovenia. We used Stress Inventory that is designed for identification of intensity and frequency of 49 situations that can play the role of teachers' work stressors. Findings showed that the major sources of stress facing teachers are factors related to work overload, factors stemming from pupils' behaviour and motivation and factors related to school system. Results also showed some small differences in perception of stressors in different groups of teachers (by gender and by teaching level.

  9. Stress determination and geomechanical stability analysis of an oil ...

    Indian Academy of Sciences (India)

    Practical data including geomechanical parameters along with drilling data from one of Iranian oilfields, Mansouri-54 well have been utilized in this analysis. in situ stress was determined using stress polygon method and conducting hydraulic fracturing data in the field. Analytical solution using the Mogi–Coulomb and the ...

  10. Thermal stresses in the space shuttle orbiter: Analysis versus test

    International Nuclear Information System (INIS)

    Grooms, H.R.; Gibson, W.F. Jr.; Benson, P.L.

    1984-01-01

    Significant temperature differences occur between the internal structure and the outer skin of the Space Shuttle Orbiter as it returns from space. These temperature differences cause important thermal stresses. A finite element model containing thousands of degrees of freedom is used to predict these stresses. A ground test was performed to verify the prediction method. The analysis and test results compare favorably. (orig.)

  11. Preliminary thermal and stress analysis of the SINQ window

    International Nuclear Information System (INIS)

    Heidenreich, G.

    1991-01-01

    Preliminary results of a finite element analysis for the SINQ proton beam window are presented. Temperatures and stresses are calculated in an axisymmetric model. As a result of these calculations, the H 2 O-cooled window (safety window) could be redesigned in such a way that plastic deformation resulting from excessive stress in some areas is avoided. (author)

  12. Is the owner entitled to radiographs taken of his animal?

    International Nuclear Information System (INIS)

    Hartung, K.

    1990-01-01

    In the Federal Republic of Germany a veterinarian owns radiographs taken of animals in his practice. They have to be filed like any other results of diagnostic procedures. This is important, because evidence is required in the case of a law suit. On the other hand, it has to be stressed that taking radiographs is the subject of a free contract between owner and veterinarian. So it is possible to take the radiographs solely with the purpose of giving them to the owner, who may have them analysed by any other veterinarian of his choice. This is especially true in hip radiographs, which are evaluated and filed by an adjudicator of the breed association. In any case the radiologist has the obligation to lend the radiographs to another veterinarian on request for inspection. The second veterinarian has to give them back as soon as possible

  13. Radiographic progession of rheumatoid arthritis

    International Nuclear Information System (INIS)

    Siozos, C.D.

    1981-01-01

    The radiographic progression of rheumatoid arthritis can be graded on a 0-IV scala. For this purpose five objective criteria are used: a) destruction, b) osteoporosis, c) narrowing of joint space, d) luxation and e) ankylosis. The grading of the radiographic progression is defined by the extent and the number of the measured alterations. The radiographic progression can be registered yearly. (orig.) [de

  14. Radiographic and tomographic study of the elbow joint in dogs

    International Nuclear Information System (INIS)

    Sendyk-Grunkraut, Alessandra; Martin, Claudia M.; Souza, Alexandre N.A.; Patricio, Geni Cristina F.; Lorigados, Carla A.B.; Matera, Julia M.; Fonseca-Pinto, Ana C.B.C.

    2017-01-01

    Elbow dysplasia disease includes an united anconeal process, fragmented medial coronoid process, osteochondrosis of humeral trochlea, articular incongruity and degenerative joint disease. The aim of this study was to present detailed morphologic and morphometric aspects of the elbow joint in dog in clinical and correlate with radiographic and tomographic (CT) exam. Inter-observer variation for articular incongruity measurements by CT, comparative analysis in the radiographic exam, angle in ulnar notch and its comparative analysis between radiographic and tomographic agreement examination in 44 elbow of dogs with different ages were evaluated. The statistics analyses included the kappa coefficient and interclass correlation and Fischer's test and McNemar's test. It was evidenced that individual performance of each radiographic incidence had poor agreement with the tomographic exam, suggesting that the accomplishment of more than two radiograph views are needed. There was no agreement between the three evaluators in the ulnar notch angle at radiographic and tomographic exams. However, there was good/moderate agreement for articular incongruity measurement in the sagittal plane between evaluators. It was possible to conclude that none of the five radiographic incidences was better than the others for radiographic analysis because each incidence had a better identification of a particular elbow compartment; measurements at the tomographic exam to evaluate radioulnar incongruity had no reproductiveness in the frontal plane, but in sagittal plan had a good/moderate agreement between observers and the angle in ulnar notch presented no repeatability at radiographic exam and no reproductiveness at tomographic exam. (author)

  15. Internal stress analysis by acoustic polarimetry

    International Nuclear Information System (INIS)

    Rouge, Jean; Robert, Andre

    The associated improvements of acoustics and electronics allow the field of applications relative to the ultrasonic methods to be extended to the non destructive control of materials and structures. Thus, the acoustical polarimetry is a new method allowing the measurement in orientation and intensity of residual or induced internal stresses in metals or other materials [fr

  16. Analysis of residual stresses in welded joints

    International Nuclear Information System (INIS)

    Lemos, F.L. de.

    1984-01-01

    The study of two stress measurements techniques is presented showing experimental results that allows to evaluate its reliability. These two methods are 'The Center Hole Drilling Method' and 'The Overcoring' and they are considered semi-destructive methods. (E.G.) [pt

  17. Radiographic interpretation of the appendicular skeleton: A comparison between casualty officers, nurse practitioners and radiographers

    International Nuclear Information System (INIS)

    Coleman, Liz; Piper, Keith

    2009-01-01

    Aim: To assess how accurately and confidently casualty officers, nurse practitioners and radiographers, practicing within the emergency department (ED), recognize and describe radiographic trauma within an image test bank of 20 appendicular radiographs. Method: The participants consisted of 7 casualty officers, 13 nurse practitioners and 18 radiographers. All 20 radiographic examinations selected for the image test bank had been acquired following trauma and included some subtle, yet clinically significant abnormalities. The test bank score (maximum 40 marks), sensitivity and specificity percentages were calculated against an agreed radiological diagnosis (reference standard). Alternative Free-response Receiver Operating Characteristic (AFROC) analysis was used to assess the overall performance of the diagnostic accuracy of these professional groups. The variation in performance between each group was measured using the analysis of variance (ANOVA) test, to identify any statistical significant differences in the performance in interpretation between these groups. The relationship between the participants' perceived image interpretation accuracy during clinical practice and the actual accuracy of their image test bank score was examined using Pearson's Correlation Coefficient (r). Results: The results revealed that the radiographers gained the highest mean test bank score (28.5/40; 71%). This score was statistically higher than the mean test bank scores attained by the participating nurse practitioners (21/40; 53%) and casualty officers (21.5/40; 54%), with p < 0.01 and p = 0.02, respectively. When compared with each other, the scores from these latter groups showed no significant difference (p = 0.91). The mean 'area under the curve' (AUC) value achieved by the radiographers was also significantly higher (p < 0.01) in comparison to the AUC values demonstrated by the nurse practitioners and casualty officers, whose results, when compared, showed no significant

  18. Residual Stress Analysis Based on Acoustic and Optical Methods

    Directory of Open Access Journals (Sweden)

    Sanichiro Yoshida

    2016-02-01

    Full Text Available Co-application of acoustoelasticity and optical interferometry to residual stress analysis is discussed. The underlying idea is to combine the advantages of both methods. Acoustoelasticity is capable of evaluating a residual stress absolutely but it is a single point measurement. Optical interferometry is able to measure deformation yielding two-dimensional, full-field data, but it is not suitable for absolute evaluation of residual stresses. By theoretically relating the deformation data to residual stresses, and calibrating it with absolute residual stress evaluated at a reference point, it is possible to measure residual stresses quantitatively, nondestructively and two-dimensionally. The feasibility of the idea has been tested with a butt-jointed dissimilar plate specimen. A steel plate 18.5 mm wide, 50 mm long and 3.37 mm thick is braze-jointed to a cemented carbide plate of the same dimension along the 18.5 mm-side. Acoustoelasticity evaluates the elastic modulus at reference points via acoustic velocity measurement. A tensile load is applied to the specimen at a constant pulling rate in a stress range substantially lower than the yield stress. Optical interferometry measures the resulting acceleration field. Based on the theory of harmonic oscillation, the acceleration field is correlated to compressive and tensile residual stresses qualitatively. The acoustic and optical results show reasonable agreement in the compressive and tensile residual stresses, indicating the feasibility of the idea.

  19. Materials properties, loads, and stress analysis, Spartan REM: Appendix A

    Science.gov (United States)

    Marlowe, D. S.; West, E. J.

    1984-01-01

    The mechanical properties, load tests, and stress analysis of the Spartan Release Engagement Mechanism (REM) is presented. The fracture properties of the components of the unit are also discussed. Detailed engineering drawings are included.

  20. Finite element analysis of thermal stress distribution in different ...

    African Journals Online (AJOL)

    Nigerian Journal of Clinical Practice • Jan-Feb 2016 • Vol 19 • Issue 1. Abstract ... Key words: Amalgam, finite element method, glass ionomer cement, resin composite, thermal stress ... applications for force analysis and assessment of different.

  1. Role stress amongst nurses at the workplace: concept analysis.

    Science.gov (United States)

    Riahi, Sanaz

    2011-09-01

    The present study explicates the concept of role stress amongst nurses through an analysis adopted from Walker and Avant; Strategies for Theory Construction in Nursing, 4th edn, Prentice Hall, New Jersey, NY. Role stress has become a significant problem amongst nurses and has created much distress leading to burnout among many in the nursing profession. It is significant to analyse the concept of role stress and its relative attributes and consequences, in order to recognize the necessary antecedents needed to create better conditions for nurses at the workplace. A modified method developed by Walker and Avant was used for this concept analysis. A model representing the concept of role stress was developed through careful consideration of the attributes, consequences, antecedents and empirical referents of role stress. The concept analysis of role stress among nurses at the workplace recognized the vulnerability of the nursing discipline towards burnout and distress in general. It is critical to be aware of the current state of health care and note the increased workload created for nurses. Nurses are at a greater vulnerability for role stress, making it imperative for health care organizations to critically evaluate and establish preventative measures for the concept of role stress. 2011 Blackwell Publishing Ltd.

  2. Comparison of two non-radiographic techniques of mixed dentition space analysis and evaluation of their reliability for Bengali population.

    Science.gov (United States)

    Dasgupta, Barun; Zahir, Shabnam

    2012-09-01

    Mixed dentition arch analysis system is an important criterion in determining the type of orthodontic treatment plan. Different mixed dentition arch analysis system are available and among them both Moyer's and Tanaka-Jhonson method of space analysis was developed for North American children. Anthropological study reveals that tooth size varies among different ethnicities The present study was performed to determine the reliability of Moyer's and Tanaka-Jhonson's method of mixed dentition arch analysis system among Bengali population. To perform the comparative evaluation of the two mixed dentition space analysis system among Bengali population. Dental casts of maxillary and mandibular arches of 70 Bengali children with permanent dentitions were fabricated. The mesiodistal crown dimensions of all erupted permanent incisors, canines, and premolars were measured with digital callipers. For particular sum of mandibular incisors, Moyer's and Tanaka-Jhonson's mixed dentition arch analysis were calculated and further statistical analysis was carried on. Descriptive statistics including the mean, standard deviation, and minimum and maximum values, unpaired't' tests, correlation coefficient "r" were calculated and tabulated. Tanaka and Johnston regression equations under-estimated the mesiodistal widths of permanent canines and premolars. On the other hand, there were no statistically significant differences between actual mesiodistal widths of canines and premolars and the predicted widths from Moyers charts at the 50% level for the lower and upper arches, among Bengali population. The study suggested that both Moyer's and Tanaka-Jhonson's mixed dentition arch analysis are applicable in Bengali population but with little modification in their regression equation.

  3. Radiographic caries diagnosis and restorative treatment decision making

    International Nuclear Information System (INIS)

    Mileman, P.A.

    1985-01-01

    This thesis is concerned with a single diagnostic technique: the bitewing radiograph, and the way it is used by dentists to decide on patient treatment need for interproximal caries. The variation in caries diagnosis and treatment decisions using bitewing radiographs is described and the radiographic criteria of choice for minimizing over and undertreatment according to a norm are investigated. Three possible diagnostic strategies in interproximal caries diagnosis using a decision analysis approach are described and evaluated, and the effect of the reported diagnostic behaviour and knowledge of practicing Dutch dentists in their use of bitewing radiographs for the diagnosis and treatment of interproximal caries is described and analyzed. (Auth.)

  4. Pocket atlas of radiographic anatomy

    International Nuclear Information System (INIS)

    Moeller, T.B.; Reif, E.; Stark, P.

    1993-01-01

    The 'Pocket Atlas of Radiographic Anatomy' presents 170 radiographs of the various body regions of adults, showing only the normal radiographic anatomy. Each radiograph is supplemented on the opposite page by a drawing of the particular body region. There is no commenting text, but the drawings are provided with captions in English. The atlas is a useful guide for interpreting radiographs. The pictures are arranged in chapters entitled as follows: Skeletal Imaging (skull, spine, upper extremity), lower extremity; Miscellaneous Plain Films (chest, mammogram, trachea, lung tomograms); Contrast Examinations (gastrointestinal tract, intravenous contrast examinations, arthrography, angiography); Special Examinations (myelograms, lymphangiograms, bronchograms, sialograms). (UWA). 348 figs [de

  5. Responses to Fiscal Stress: A Comparative Analysis

    Science.gov (United States)

    2013-12-01

    of “a significant decline in market share by the middle of the 20th century as travelers and shippers turned increasingly to airlines, trucks, and...1995). Intercity passenger rail: Financial and operating conditions threaten Amtrak’s long-term viability (GAO-95-71). Washington, DC: U.S...I. (1980). Retrenchment and flexibility in public organizations. Fiscal Stress and Public Policy, 159–178. Scheinberg, P. F. (1998). Intercity

  6. Comparison of two non-radiographic techniques of mixed dentition space analysis and evaluation of their reliability for Bengali population

    Directory of Open Access Journals (Sweden)

    Barun Dasgupta

    2012-01-01

    Full Text Available Context: Mixed dentition arch analysis system is an important criterion in determining the type of orthodontic treatment plan. Different mixed dentition arch analysis system are available and among them both Moyer′s and Tanaka-Jhonson method of space analysis was developed for North American children. Anthropological study reveals that tooth size varies among different ethnicities The present study was performed to determine the reliability of Moyer′s and Tanaka-Jhonson′s method of mixed dentition arch analysis system among Bengali population. Aims: To perform the comparative evaluation of the two mixed dentition space analysis system among Bengali population. Materials and Methods: Dental casts of maxillary and mandibular arches of 70 Bengali children with permanent dentitions were fabricated. The mesiodistal crown dimensions of all erupted permanent incisors, canines, and premolars were measured with digital callipers. For particular sum of mandibular incisors, Moyer′s and Tanaka-Jhonson′s mixed dentition arch analysis were calculated and further statistical analysis was carried on. Statistical analysis used: Descriptive statistics including the mean, standard deviation, and minimum and maximum values, unpaired′t′ tests, correlation coefficient "r" were calculated and tabulated. Results: Tanaka and Johnston regression equations under-estimated the mesiodistal widths of permanent canines and premolars. On the other hand, there were no statistically significant differences between actual mesiodistal widths of canines and premolars and the predicted widths from Moyers charts at the 50% level for the lower and upper arches, among Bengali population. Conclusions: The study suggested that both Moyer′s and Tanaka-Jhonson′s mixed dentition arch analysis are applicable in Bengali population but with little modification in their regression equation.

  7. Municipal solid waste effective stress analysis

    International Nuclear Information System (INIS)

    Shariatmadari, Nader; Machado, Sandro Lemos; Noorzad, Ali; Karimpour-Fard, Mehran

    2009-01-01

    The mechanical behavior of municipal solid waste (MSW) has attracted the attention of many researchers in the field of geo-environmental engineering in recent years and several aspects of waste mechanical response under loading have been elucidated. However, the mechanical response of MSW materials under undrained conditions has not been described in detail to date. The knowledge of this aspect of the MSW mechanical response is very important in cases involving MSW with high water contents, seismic ground motion and in regions where landfills are built with poor operation conditions. This paper presents the results obtained from 26 large triaxial tests performed both in drained and undrained conditions. The results were analyzed taking into account the waste particles compressibility and the deformation anisotropy of the waste samples. The waste particles compressibility was used to modify the Terzaghi effective stress equation, using the Skempton (1961) proposition. It is shown that the use of the modified effective stress equation led to much more compatible shear strength values when comparing Consolidated-Drained (CD) and Consolidated-Undrained (CU), results, explaining the high shear strength values obtained in CU triaxial tests, even when the pore pressure is almost equal to the confining stress.

  8. Lateral cephalometric analysis for treatment planning in orthodontics based on MRI compared with radiographs: A feasibility study in children and adolescents.

    Science.gov (United States)

    Heil, Alexander; Lazo Gonzalez, Eduardo; Hilgenfeld, Tim; Kickingereder, Philipp; Bendszus, Martin; Heiland, Sabine; Ozga, Ann-Kathrin; Sommer, Andreas; Lux, Christopher J; Zingler, Sebastian

    2017-01-01

    The objective of this prospective study was to evaluate whether magnetic resonance imaging (MRI) is equivalent to lateral cephalometric radiographs (LCR, "gold standard") in cephalometric analysis. The applied MRI technique was optimized for short scanning time, high resolution, high contrast and geometric accuracy. Prior to orthodontic treatment, 20 patients (mean age ± SD, 13.95 years ± 5.34) received MRI and LCR. MRI datasets were postprocessed into lateral cephalograms. Cephalometric analysis was performed twice by two independent observers for both modalities with an interval of 4 weeks. Eight bilateral and 10 midsagittal landmarks were identified, and 24 widely used measurements (14 angles, 10 distances) were calculated. Statistical analysis was performed by using intraclass correlation coefficient (ICC), Bland-Altman analysis and two one-sided tests (TOST) within the predefined equivalence margin of ± 2°/mm. Geometric accuracy of the MRI technique was confirmed by phantom measurements. Mean intraobserver ICC were 0.977/0.975 for MRI and 0.975/0.961 for LCR. Average interobserver ICC were 0.980 for MRI and 0.929 for LCR. Bland-Altman analysis showed high levels of agreement between the two modalities, bias range (mean ± SD) was -0.66 to 0.61 mm (0.06 ± 0.44) for distances and -1.33 to 1.14° (0.06 ± 0.71) for angles. Except for the interincisal angle (p = 0.17) all measurements were statistically equivalent (p feasibility of orthodontic treatment planning without radiation exposure based on MRI. High-resolution isotropic MRI datasets can be transformed into lateral cephalograms allowing reliable measurements as applied in orthodontic routine with high concordance to the corresponding measurements on LCR.

  9. Radiographic findings in immunodeficiency

    International Nuclear Information System (INIS)

    Obregon, R.; Lynch, D.A.; Cink, T.M.; Newell, J.D.; Kirkpatrick, C.

    1991-01-01

    This paper reviews the chest radiographs and high-resolution CT (HRCT) scans in patients with immunodeficiency disorders and define the role of HRCT. Thirty-three cases were retrospectively graded according to the consensus of two radiologists. Patients with HIV seropositivity and asthma were excluded. HRCT was performed in 12 cases with standard techniques. Diagnoses included common variable hypogammaglobulinemia (n = 19), X-linked agammaglobulinemia (n = 4), chronic mucocutaneous candidiasis (n = 4), and selective immunoglobulin g deficiencies (n = 2). Chest radiographs showed bronchiectasis in 11 of 33 cases with a predominant lower lobe distribution (82%). Nodules were present in six cases and mucus plugs in four cases. HRCT showed bronchiectasis in nine of 12 cases; in five of these nine cases, bronchiectasis was not apparent on chest radiographs. Other HRCT findings included segmental air trapping (four of 12), mucus plugs (three of 12), hazy consolidation (four of 12), nodules (five of 12), and bronchiolectasis (two of 12). Therapy was altered in seven of 12 cases in which HRCT was performed. Most pertinent to clinical management were the presence of a thymoma (n = 1) and severe focal of diffuse bronchiectasis

  10. Large Format Radiographic Imaging

    International Nuclear Information System (INIS)

    Rohrer, J. S.; Stewart, Lacey; Wilke, M. D.; King, N. S.; Baker A, S.; Lewis, Wilfred

    1999-01-01

    Radiographic imaging continues to be a key diagnostic in many areas at Los Alamos National Laboratory (LANL). Radiographic recording systems have taken on many form, from high repetition-rate, gated systems to film recording and storage phosphors. Some systems are designed for synchronization to an accelerator while others may be single shot or may record a frame sequence in a dynamic radiography experiment. While film recording remains a reliable standby in the radiographic community, there is growing interest in investigating electronic recording for many applications. The advantages of real time access to remote data acquisition are highly attractive. Cooled CCD camera systems are capable of providing greater sensitivity with improved signal-to-noise ratio. This paper begins with a review of performance characteristics of the Bechtel Nevada large format imaging system, a gated system capable of viewing scintillators up to 300 mm in diameter. We then examine configuration alternatives in lens coupled and fiber optically coupled electro-optical recording systems. Areas of investigation include tradeoffs between fiber optic and lens coupling, methods of image magnification, and spectral matching from scintillator to CCD camera. Key performance features discussed include field of view, resolution, sensitivity, dynamic range, and system noise characteristics

  11. Radiograph identifying means

    International Nuclear Information System (INIS)

    Sheldon, A.D.

    1983-01-01

    A flexible character-indentable plastics embossing tape is backed by and bonded to a lead strip, not more than 0.025 inches thick, to form a tape suitable for identifying radiographs. The lead strip is itself backed by a relatively thin and flimsy plastics or fabric strip which, when removed, allows the lead plastic tape to be pressure-bonded to the surface to be radiographed. A conventional tape-embossing gun is used to indent the desired characters in succession into the lead-backed tape, without necessarily severing the lead; and then the backing strip is peeled away to expose the layer of adhesive which pressure-bonds the indented tape to the object to be radiographed. X-rays incident on the embossed tape will cause the raised characters to show up dark on the subsequently-developed film, whilst the raised side areas will show up white. Each character will thus stand out on the developed film. (author)

  12. X-ray stress analysis in textured polycrystalline materials

    International Nuclear Information System (INIS)

    Yokoyama, Ryouichi; Harada, Jimpei

    2010-01-01

    The relationship between stress and strain in polycrystalline materials with fibre texture is examined on the basis of the strain analysis in the constituent crystallites within the Reuss approximation. By introducing the symmetry of reciprocal lattices for the constituent crystallites, the physical meaning of taking an average of the strains observed by X-ray diffraction (XRD) is made clear. By using formulae obtained by the present treatment for the stress-strain relation in cubic specimens with fibre texture in the Laue classes m3-bar m hkl Bragg reflections with h≠k≠l split into doublets owing to the existence of crystallites with two different orientations under the stress field. This technique was confirmed by the profile analysis in XRD data observed for reflections of 222 and 420 in a cubic TiN thin film sputtered on a polyimide film. The technique of the stress analysis and its confirmation are introduced. (author)

  13. Radiographic indices for lumbar developmental spinal stenosis

    Directory of Open Access Journals (Sweden)

    Jason Pui Yin Cheung

    2017-02-01

    Full Text Available Abstract Background Patients with developmental spinal stenosis (DSS are susceptible to developing symptomatic stenosis due to pre-existing narrowed spinal canals. DSS has been previously defined by MRI via the axial anteroposterior (AP bony spinal canal diameter. However, MRI is hardly a cost-efficient tool for screening patients. X-rays are superior due to its availability and cost, but currently, there is no definition of DSS based on plain radiographs. Thus, the aim of this study is to develop radiographic indices for diagnosing DSS. Methods This was a prospective cohort of 148 subjects consisting of patients undergoing surgery for lumbar spinal stenosis (patient group and asymptomatic subjects recruited openly from the general population (control group. Ethics approval was obtained from the local institutional review board. All subjects underwent MRI for diagnosing DSS and radiographs for measuring parameters used for creating the indices. All measurements were performed by two independent investigators, blinded to patient details. Intra- and interobserver reliability analyses were conducted, and only parameters with near perfect intraclass correlation underwent receiver operating characteristic (ROC analysis to determine the cutoff values for diagnosing DSS using radiographs. Results Imaging parameters from a total of 66 subjects from the patient group and 82 asymptomatic subjects in the control group were used for analysis. ROC analysis suggested sagittal vertebral body width to pedicle width ratio (SBW:PW as having the strongest sensitivity and specificity for diagnosing DSS. Cutoff indices for SBW:PW were level-specific: L1 (2.0, L2 (2.0, L3 (2.2, L4 (2.2, L5 (2.5, and S1 (2.8. Conclusions This is the first study to define DSS on plain radiographs based on comparisons between a clinically relevant patient group and a control group. Individuals with DSS can be identified by a simple radiograph using a screening tool allowing for better

  14. Reliability analysis of offshore structures using OMA based fatigue stresses

    DEFF Research Database (Denmark)

    Silva Nabuco, Bruna; Aissani, Amina; Glindtvad Tarpø, Marius

    2017-01-01

    focus is on the uncertainty observed on the different stresses used to predict the damage. This uncertainty can be reduced by Modal Based Fatigue Monitoring which is a technique based on continuously measuring of the accelerations in few points of the structure with the use of accelerometers known...... points of the structure, the stress history can be calculated in any arbitrary point of the structure. The accuracy of the estimated actual stress is analyzed by experimental tests on a scale model where the obtained stresses are compared to strain gauges measurements. After evaluating the fatigue...... stresses directly from the operational response of the structure, a reliability analysis is performed in order to estimate the reliability of using Modal Based Fatigue Monitoring for long term fatigue studies....

  15. Interlaminar stress analysis for carbon/epoxy composite space rotors

    Directory of Open Access Journals (Sweden)

    C Lian

    2016-09-01

    Full Text Available This paper extends the previous works that appears in the International Journal of Multiphysics, Varatharajoo, Salit and Goh (2010. An approach incorporating cohesive zone modelling technique is incorporated into an optimized flywheel to properly simulate the stresses at the layer interfaces. Investigation on several fiber stacking sequences are also conducted to demonstrate the effect of fiber orientations on the overall rotor stress as well as the interface stress behaviour. The results demonstrated that the rotor interlaminar stresses are within the rotor materials' ultimate strength and that the fiber direction with a combination of 45°/-45°/0° offers the best triple layer rotor among the few combinations selected for this analysis. It was shown that the present approach can facilitate also further investigation on the interface stress behaviour of rotating rotors.

  16. Analysis of a radiological incident and lessons to be learned: a case of industrial radiographic incident in great Britain

    International Nuclear Information System (INIS)

    Croft, J.; Lefaure, Ch.

    2000-01-01

    This note describes a case study to provide feedback analysis and lessons to be learned from a radiological incident. This one occurred in the UK. It has been published in the European ALARA Newsletter no. 2 (January 1997) and has been selected from the IRID database (Ionising Radiation Incident Database) managed by the Health and Safety Executive, National Radiological Protection Board and Environmental Agency. (authors)

  17. The radiographic investigation of two Egyptian mummies.

    Science.gov (United States)

    Fodor, J; Malott, J C; King, A Y

    1983-01-01

    Radiography is a well-recognized method of nondestructive analysis of art objects and ancient relics. The methods and techniques used in the examination of two ancient Egyptian mummies are presented here. Additionally, the use of radiographic findings to help substantiate alleged historical information and to establish sex, age, and pathology of each specimen is discussed.

  18. Analysis of rock stress and rock stress measurements with application to Aespoe HRL

    International Nuclear Information System (INIS)

    Lundholm, Beatrice

    2000-11-01

    the opening where no influence from the openings can be expected. Since the magnitudes of the rock stresses differ between overcoring and hydraulic fracturing, some efforts have been made to find possible causes for this. The rock stresses when conducting overcoring gave higher values overall, which could be explained by high Poisson's ratios and a minor influence from the opening as the stress measurements might have been done in the disturbed zone. The high Poisson's ratio may depend on the stress-induced microcracks, which might be initiated during the overcoring of the cell, during the drilling of the pilot borehole, in which the cell is installed, and during biaxial testing. Statistical analysis showed that there is significant differences between the mean values of Poisson's ratio obtained from biaxial tests of cores containing the CSIRO HI-cell and the SSPB-cell. Poisson's ratio is about 0.34 for CSIRO HI-cell while the SSPB-cell gave a Poisson's ratio of 0.23. The analysis also showed that Young's modulus does not differ between the techniques. The modelling in FLAC was made to simulate the overcoring and biaxial testing. The result show that it is possible to obtain extensional strain in the core during overcoring if the major principal stress is perpendicular to the borehole axis. This may lead to microcracking occurring in the core causing high Poisson's ratio, which results in higher stresses. It can also be seen from the simulation of the biaxial testing that extensional strain is achieved even if the hollow core is not damaged during overcoring. The analyses using UDEC was made to study the effect of different properties of a discontinuity, such as the dip angle, Young's modulus, Poisson's ratio, density and the normal and shear stiffness. The analyses showed that an inclined discontinuity affects the stresses especially if sliding occurs. So, the dip angle does not solely, determine the amount of disturbance of the state of stress around a discontinuity

  19. Analysis of residual stresses in a long hollow cylinder

    International Nuclear Information System (INIS)

    Tokovyy, Yuriy V.; Ma, Chien-Ching

    2011-01-01

    This paper presents an analytical method for solving the axisymmetric stress problem for a long hollow cylinder subjected to locally-distributed residual (incompatible) strains. This method is based on direct integration of the equilibrium and compatibility equations, which thereby have been reduced to the set of two governing equations for two key functions with corresponding boundary and integral conditions. The governing equations were solved by making use of the Fourier integral transformation. Application of the method is illustrated with an analysis of the welding residual stresses in a butt-welded thick-walled pipe. - Highlights: → A solution to the axisymmetric stress problem for a hollow cylinder is constructed. → The cylinder is subjected to a field of locally-distributed residual strains. → The method is based on direct integration of the equilibrium equations. → An application of our solution to analysis of welding residual stresses is considered.

  20. Stress analysis and life prediction of gas turbine blade

    Science.gov (United States)

    Hsiung, H. C.; Dunn, A. J.; Woodling, D. R.; Loh, D. L.

    1988-01-01

    A stress analysis procedure is presented for a redesign of the Space Shuttle Main Engine high pressure fuel turbopump turbine blades. The analysis consists of the one-dimensional scoping analysis to support the design layout and the follow-on three-dimensional finite element analysis to confirm the blade design at operating loading conditions. Blade life is evaluated based on high-cycle fatigue and low-cycle fatigue.

  1. CANDIDATE GENE ANALYSIS IN ISRAELI SOLDIERS WITH STRESS FRACTURES

    Directory of Open Access Journals (Sweden)

    Ran Yanovich

    2012-03-01

    Full Text Available To investigate the association of polymorphisms within candidate genes which we hypothesized may contribute to stress fracture predisposition, a case-control, cross- sectional study design was employed. Genotyping 268 Single Nucleotide Polymorphisms- SNPs within 17 genes in 385 Israeli young male and female recruits (182 with and 203 without stress fractures. Twenty-five polymorphisms within 9 genes (NR3C1, ANKH, VDR, ROR2, CALCR, IL6, COL1A2, CBG, and LRP4 showed statistically significant differences (p < 0.05 in the distribution between stress fracture cases and non stress fracture controls. Seventeen genetic variants were associated with an increased stress fracture risk, and eight variants with a decreased stress fracture risk. None of the SNP associations remained significant after correcting for multiple comparisons (false discovery rate- FDR. Our findings suggest that genes may be involved in stress fracture pathogenesis. Specifically, the CALCR and the VDR genes are intriguing candidates. The putative involvement of these genes in stress fracture predisposition requires analysis of more cases and controls and sequencing the relevant genomic regions, in order to define the specific gene mutations

  2. Stresses, fatigue and fracture analysis in the tube sheets

    International Nuclear Information System (INIS)

    Billon, F.

    1986-05-01

    The purpose of the present work is to study the behaviour of the nuclear PWR steam generator tube sheet. But the methods developed in this field can easily be generalized in order to study tube sheets from any other type of heat exchangers. The aim of the stress analysis of these sheets is to verify their correct design, to quantify the risk of fatigue damage in the areas submitted to a high stress concentration and through the fracture mechanic, to make sure there is no risk of fast fracture resulting from initiated or pre-existing defects. This analysis necessarily relates to the calculation of stresses in all parts of the multidrilled area, mainly around the holes where they are concentrated. However the tube sheets are so complexe structures that their direct modelization cannot be envisaged within the context of the finite element method. We then must refer to the concept of equivalent medium in order to calculate the nominal stresses. Then using the stresses multiple fonctions appropriate to the net geometry, we can calculate the actual stresses concentrated around the holes. The method depends on the behaviour of the elementary volume which represents the behaviour of the multidrilled medium. This approach must allow to correctly take account of the ''thermal skin effect'', which is a phenomenon particular to the tube sheets with thermal loads. It must as well be generalized in order to analyse the irregular ligaments which affect the periodical stresses distribution and locally overconcentrate them [fr

  3. Oil prices and financial stress: A volatility spillover analysis

    International Nuclear Information System (INIS)

    Nazlioglu, Saban; Soytas, Ugur; Gupta, Rangan

    2015-01-01

    This paper examines whether there is a volatility transmission between oil prices and financial stress by means of the volatility spillover test. We employ WTI crude oil prices and Cleveland financial stress index for the period 1991–2014 and divide the sample into pre-crisis, in-crisis, and post-crisis periods due to the downward trend in oil price in 2008. The volatility model estimations indicate that oil prices and financial stress index are dominated by long-run volatility. The volatility spillover causality test supports evidence on risk transfer from oil prices to financial stress before the crisis and from financial stress to oil prices after the crisis. The impulse response analysis shows that the volatility transmission pattern has similar dynamics before and after the crisis and is characterized by higher and long-lived effects during the crisis. Our results have implications for both policy makers and investors, and for future work. -- Highlights: •Volatility spillover between oil prices and financial stress index is examined. •Analysis is conducted for sub-periods: pre-crisis, in-crisis, and post-crisis •Oil prices spill on financial stress before the crisis, but spillover reversed after the crisis. •Volatility transmission pattern has similar dynamics before and after the crisis. •Implications for investors and policy makers are discussed

  4. An Integrated Analysis of Changes in Water Stress in Europe

    DEFF Research Database (Denmark)

    Henrichs, T.; Lehner, B.; Alcamo, J.

    2002-01-01

    Future changes in water availability with climate change and changes in water use due to socio-economic development are to occur in parallel. In an integrated analysis we bring together these aspects of global change in a consistent manner, and analyse the water stress situation in Europe. We find...... that today high water stress exists in one-fifth of European river basin area. Under a scenario projection, increases in water use throughout Eastern Europe are accompanied by decreases in water availability in most of Southern Europe--combining these trends leads to a marked increase in water stress...

  5. Numerical analysis of interacting cracks in biaxial stress field

    International Nuclear Information System (INIS)

    Kovac, M.; Cizelj, L.

    1999-01-01

    The stress corrosion cracks as seen for example in PWR steam generator tubing made of Inconel 600 usually produce highly irregular kinked and branched crack patterns. Crack initialization and propagation depends on stress state underlying the crack pattern. Numerical analysis (such as finite element method) of interacting kinked and branched cracks can provide accurate solutions. This paper discusses the use of general-purpose finite element code ABAQUS for evaluating stress fields at crack tips of interacting complex cracks. The results obtained showed reasonable agreement with the reference solutions and confirmed use of finite elements in such class of problems.(author)

  6. Stress analysis of the tokamak engineering test breeder blanket

    International Nuclear Information System (INIS)

    Huang Zhongqi

    1992-01-01

    The design features of the hybrid reactor blanket and main parameters are presented. The stress analysis is performed by using computer codes SAP5p and SAP6 with the three kinds of blanket module loadings, i.e, the pressure of coolant, the blanket weight and the thermal loading. Numerical calculation results indicate that the stresses of the blanket are smaller than the allowable ones of the material, the blanket design is therefore reasonable

  7. Temperature and thermal stress analysis of a switching tube anode

    International Nuclear Information System (INIS)

    Sutton, S.B.

    1979-01-01

    In the design of high power density switching tubes which are subjected to cyclic thermal loads, the temperature induced stresses must be minimized in order to maximize the life expectancy of the tube. Following are details of an analysis performed for the Magnetic Fusion Program at the Lawrence Livermore Laboratory on a proposed tube. The tube configuration is given. The problem was simplified to one-dimensional approximations for both the thermal and stress analyses. The underlying assumptions and their implications are discussed

  8. Radiographic evaluation of osteosynthesis

    International Nuclear Information System (INIS)

    Mueller-Miny, H.; Erlemann, R.; Roos, N.; Peters, P.E.; Baranowski, D.

    1991-01-01

    Surgeons, orthopedic surgeons, and neurosurgeons employ a wide variety of different osteosynthetic devices in the treatment of fractures and in spinal surgery. In order to assess these instruments correctly, the radiologist should be aware of their purpose and normal apperance. The complications should be identified, such as delayed union, pseudarthrosis, dislocation, device loosening, fracture of the device, osteomyelitis, and refracture. To evaluate the fixation device adequately two plain radiographs are mandatory. An normal fracture healing and the most commonly used fixation devices, the abnormalities of fracture healing and their complications are discussed. (orig.) [de

  9. Digitization of conventional radiographs

    International Nuclear Information System (INIS)

    Wenz, W.; Buitrago-Tellez, C.; Blum, U.; Hauenstein, K.H.; Gufler, H.; Meyer, E.; Ruediger, K.

    1992-01-01

    The diagnostic value of a digitization system for analogue films based on a charge-coupled-device (CCD) scanner with adjustable resolution of 2.5 or 5 lp/mm was assessed. Some 110 skeletal radiographs, 50 contrast studies, including 25 of patients with Crohn's disease, and 70 abdominal plain films before and after successful lithotripsy for renal stones were digitized. Receiver operating characteristic (ROC) studies showed improved detection of cortical and trabecular defects with contrast-optimized digitized films. Edge enhancement algorithms yielded no additional information. Inflammatory lesions of Crohn's disease were detected equally well by conventional films and digitized images. A statistically significant improvement (p [de

  10. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Bevan, J.A.

    1983-01-01

    This invention relates to radiodiagnostic agents and more particularly to a composition and method for preparing a highly effective technetium-99m-based bone scanning agent. One deficiency of x-ray examination is the inability of that technique to detect skeletal metastases in their incipient stages. It has been discovered that the methanehydroxydiphosphonate bone mineral-seeking agent is unique in that it provides the dual benefits of sharp radiographic imaging and excellent lesion detection when used with technetium-99m. This agent can also be used with technetium-99m for detecting soft tissue calcification in the manner of the inorganic phosphate radiodiagnostic agents

  11. Radiographic film digitizing devices

    International Nuclear Information System (INIS)

    McFee, W.H.

    1988-01-01

    Until recently, all film digitizing devices for use with teleradiology or picture archiving and communication systems used a video camera to capture an image of the radiograph for subsequent digitization. The development of film digitizers that use a laser beam to scan the film represents a significant advancement in digital technology, resulting in improved image quality compared with video scanners. This paper discusses differences in resolution, efficiency, reliability, and the cost between these two types of devices. The results of a modified receiver operating characteristic comparison study of a video scanner and a laser scanner manufactured by the same company are also discussed

  12. Texture analysis of clinical radiographs using radon transform on a local scale for differentiation between post-menopausal women with and without hip fracture

    Science.gov (United States)

    Boehm, Holger F.; Körner, Markus; Baumert, Bernhard; Linsenmaier, Ulrich; Reiser, Maximilian

    2011-03-01

    Osteoporosis is a chronic condition characterized by demineralization and destruction of bone tissue. Fractures associated with the disease are becoming an increasingly relevant issue for public health institutions. Prediction of fracture risk is a major focus research and, over the years, has been approched by various methods. Still, bone mineral density (BMD) obtained by dual-energy X-ray absorptiometry (DXA) remains the clinical gold-standard for diagnosis and follow-up of osteoporosis. However, DXA is restricted to specialized diagnostic centers and there exists considerable overlap in BMD results between populations of individuals with and without fractures. Clinically far more available than DXA is conventional x-ray imaging depicting trabecular bone structure in great detail. In this paper, we demonstrate that bone structure depicted by clinical radiographs can be analysed quantitatively by parameters obtained from the Radon Transform (RT). RT is a global analysis-tool for detection of predefined, parameterized patterns, e.g. straight lines or struts, representing suitable approximations of trabecular bone texture. The proposed algorithm differentiates between patients with and without fractures of the hip by application of various texture-metrics based on the Radon-Transform to standard x-ray images of the proximal femur. We consider three different regions-of-interest in the proximal femur (femoral head, neck, and inter-trochanteric area), and conduct an analysis with respect to correct classification of the fracture status. Performance of the novel approach is compared to DXA. We draw the conclusion that performance of RT is comparable to DXA and may become a useful supplement to densitometry for the prediction of fracture risk.

  13. Interpreting radiographs. 4. The carpus

    International Nuclear Information System (INIS)

    Burguez, P.N.

    1984-01-01

    The complexity of the carpus which has three major joints, seven or eight carpal bones and five adjacent bones, each of which articulates with one or more of the carpal elements, necessitates good quality radiographs for definitive radiographic interpretation may be extremely difficult because of the disparity between radiographic changes and obvious clinical signs and, therefore, must be discussed in the light of a thorough clinical assessment

  14. Automated computer analysis of x-ray radiographs greatly facilitates measurement of coating-thickness variations in laser-fusion targets

    International Nuclear Information System (INIS)

    Stupin, D.M.; Moore, K.R.; Thomas, G.D.; Whitman, R.L.

    1981-01-01

    An automated system was built to analyze x-ray radiographs of laser fusion targets which greatly facilitates the detection of coating thickness variations. Many laser fusion targets reqire opaque coatings 1 to 20 μm thick which have been deposited on small glass balloons 100 to 500 μm in diameter. These coatings must be uniformly thick to 1% for the targets to perform optimally. Our system is designed to detect variations as small as 100 A in 1-μm-thick coatings by converting the optical density variations of contact x-ray radiographs into coating thickness variations. Radiographic images are recorded in HRP emulsions and magnified by an optical microscope, imaged onto television camera, digitized and processed on a Data General S/230 computer with a code by Whitman. After an initial set-up by the operator, as many as 200 targets will be automatically characterized

  15. Analysis of changes in radiographic lung image and lung ventilation disorders in workers occupationally exposed to chrysotile in the past

    Directory of Open Access Journals (Sweden)

    Elżbieta Cwynar

    2017-04-01

    Full Text Available Background: The adverse health effects of occupational exposure to asbestos dust may occur several years after first exposure. The objective of the study was to assess the relationship between lesions in the respiratory system and the factors contributing to occupational exposure to asbestos described in the first medical examination as well as to analyze the factors responsible for the progression of these changes in further medical tests. Material and Methods: The study group comprised 591 former workers of asbestos processing plant “Gambit” in Lubawka. The results of medical examinations carried out in 2001–2012 were assessed. Statistical inference was performed based on bilateral significance tests at the 0.05 level of significance. Results: A higher risk of interstitial lung changes along with an increase in the cumulative concentration of asbestos was indicated; for the employees with the highest exposure, the adjusted odds ratio (OR was 1.63 (95% confidence interval (CI: 0.99–2.71, while for changes with the severity degree qualifying for asbestosis diagnosis, the risk was significantly increased, over fivefold higher, compared to subjects employed in the lowest exposure. The analysis of the relationship between the progression of interstitial changes and the exposure to asbestos dust showed a fourfold higher risk of the progression in workers employed in the highest exposure. Mean values of FEV1 (forced expiratory volume in 1 s, FVC (forced vital capacity, FEV1/FVC (forced expiratory volume in 1 s to forced vital capacity were significantly lower in the subjects working in a higher asbestos exposure. The effect of tobacco smoking on the occurrence of interstitial lung changes and their progression was also confirmed. Conclusions: The results of prophylactic medical examinations of the health status of workers formerly employed in the plants using chrysotile indicate the importance andthe need for a long-term clinical follow

  16. Transcriptome Analysis of Sunflower Genotypes with Contrasting Oxidative Stress Tolerance Reveals Individual- and Combined- Biotic and Abiotic Stress Tolerance Mechanisms.

    Directory of Open Access Journals (Sweden)

    Vemanna S Ramu

    Full Text Available In nature plants are often simultaneously challenged by different biotic and abiotic stresses. Although the mechanisms underlying plant responses against single stress have been studied considerably, plant tolerance mechanisms under combined stress is not understood. Also, the mechanism used to combat independently and sequentially occurring many number of biotic and abiotic stresses has also not systematically studied. From this context, in this study, we attempted to explore the shared response of sunflower plants to many independent stresses by using meta-analysis of publically available transcriptome data and transcript profiling by quantitative PCR. Further, we have also analyzed the possible role of the genes so identified in contributing to combined stress tolerance. Meta-analysis of transcriptomic data from many abiotic and biotic stresses indicated the common representation of oxidative stress responsive genes. Further, menadione-mediated oxidative stress in sunflower seedlings showed similar pattern of changes in the oxidative stress related genes. Based on this a large scale screening of 55 sunflower genotypes was performed under menadione stress and those contrasting in oxidative stress tolerance were identified. Further to confirm the role of genes identified in individual and combined stress tolerance the contrasting genotypes were individually and simultaneously challenged with few abiotic and biotic stresses. The tolerant hybrid showed reduced levels of stress damage both under combined stress and few independent stresses. Transcript profiling of the genes identified from meta-analysis in the tolerant hybrid also indicated that the selected genes were up-regulated under individual and combined stresses. Our results indicate that menadione-based screening can identify genotypes not only tolerant to multiple number of individual biotic and abiotic stresses, but also the combined stresses.

  17. Stress analysis of longwall top coal caving

    Energy Technology Data Exchange (ETDEWEB)

    Alehossein, H.; Poulsen, B.A. [CSIRO Exploration & Mining, Brisbane, Qld. (Australia)

    2010-01-15

    Longwall top coal caving (LTCC) is a relatively new method of mining thick coal seams that is currently achieving high productivity and efficiency. The technique is similar to traditional longwall mining in that a cutting head slices coal from the lower section of the coal seam onto a conveyor belt installed in front of the hydraulic support near the cutting face. In modern LTCC an additional rear conveyor belt is located behind the support, to which the flow of the caved coal from the upper part of the seam can be controlled by a moveable flipper attached to the canopy of the support. The mining method relies on the fracturing of the top coal by the front abutment pressure to achieve satisfactory caving into the rear conveyor. This paper develops a yield and caveability criterion based on in situ conditions in the top coal in advance of the mining face (yield) and behind the supports (caveability). Yielding and caving effects are combined into one single number called caving number (CN), which is the multiplication result of caving factor (CF) and yield factor (YF). Analytical derivations are based on in situ stress conditions, Mohr-Coulomb and/or Hoek-Brown rock failure criteria and an on-associated elastoplastic strain softening material behaviour. The yield and caveability criteria are in agreement with results from both numerical studies and mine data. The caving number is normalised to mining conditions of a reference Chinese mine (LMX mine) and is used to assess LTCC performance at fourteen other Chinese working longwalls that have had varying success with the LTCC technology. As a predictive model, results of this analytical/numerical study are useful to assess the potential success of caving in new LTCC operations and in different mining conditions.

  18. Stress analysis program system for nuclear vessel: STANSAS

    International Nuclear Information System (INIS)

    Okamoto, Asao; Michikami, Shinsuke

    1979-01-01

    IHI has developed a computer system of stress analysis and evaluation for nuclear vessels: STANSAS (STress ANalysis System for Axi-symmetric Structure). The system consists of more than twenty independent programs divided into the following six parts. 1. Programs for opening design by code rule. 2. Calculation model generating programs. 3. Load defining programs. 4. Structural analysis programs. 5. Load data/calculation results plotting programs. 6. Stress evaluation programs. Each program is connected with its pre- or post-processor through three data-bases which enable automatic data transfer. The user can make his choice of structural analysis programs in accordance with the problem to be solved. The interface to STANSAS can be easily installed in generalized structural analysis programs such as NASTRAN and MARC. For almost all tables and figures in the stress report, STANSAS has the function to print or plot out. The complicated procedures of ''Design by Analysis'' for pressure vessels have been well standardized by STANSAS. The system will give a high degree of efficiency and confidence to the design work. (author)

  19. Radiographer interpretation of trauma radiographs: Issues for radiography education providers

    International Nuclear Information System (INIS)

    Hardy, Maryann; Snaith, Beverly

    2009-01-01

    Background: The role of radiographers with respect to image interpretation within clinical practice is well recognised. It is the expectation of the professional, regulatory and academic bodies that upon qualification, radiographers will possess image interpretation skills. Additionally, The College of Radiographers has asserted that its aspiration is for all radiographers to be able to provide an immediate written interpretation on skeletal trauma radiographs by 2010. This paper explores the readiness of radiography education programmes in the UK to deliver this expectation. Method: A postal questionnaire was distributed to 25 Higher Education Institutions in the UK (including Northern Ireland) that provided pre-registration radiography education as identified from the Society and College of Radiographers register. Information was sought relating to the type of image interpretation education delivered at pre- and post-registration levels; the anatomical range of image interpretation education; and education delivery styles. Results: A total of 19 responses (n = 19/25; 76.0%) were received. Image interpretation education was included as part of all radiographer pre-registration programmes and offered at post-registration level at 12 academic centres (n = 12/19; 63.2%). The anatomical areas and educational delivery methods varied across institutions. Conclusion: Radiography education providers have embraced the need for image interpretation education within both pre- and post-registration radiography programmes. As a result, UK education programmes are able to meet the 2010 College of Radiographers aspiration.

  20. Stress Analysis for the Critical Metal Structure of Bridge Crane

    Science.gov (United States)

    Ling, Zhangwei; Wang, Min; Xia, Junfang; Wang, Songhua; Guo, Xiaolian

    2018-01-01

    Based on the type of connection between the main girder and end beam of electrical single beam crane, the finite element analysis model of a full portal crane was established. The stress distribution of the critical structure under different loading conditions was analyzed. The results shown that the maximum Mises stress and deflection of the main girder were within the allowable range. And the connecting location between end beam web and main girder had higher stress than other region, especially at the lower edge and upper edge of the end beam web and the area near the bolt hole of upper wing panel. Therefore it is important to inspect the connection status, the stress condition and the crack situation nearing connection location during the regular inspection process to ensure the safety of the connection between the main girder and end beam.

  1. Non-linear elastic thermal stress analysis with phase changes

    International Nuclear Information System (INIS)

    Amada, S.; Yang, W.H.

    1978-01-01

    The non-linear elastic, thermal stress analysis with temperature induced phase changes in the materials is presented. An infinite plate (or body) with a circular hole (or tunnel) is subjected to a thermal loading on its inner surface. The peak temperature around the hole reaches beyond the melting point of the material. The non-linear diffusion equation is solved numerically using the finite difference method. The material properties change rapidly at temperatures where the change of crystal structures and solid-liquid transition occur. The elastic stresses induced by the transient non-homogeneous temperature distribution are calculated. The stresses change remarkably when the phase changes occur and there are residual stresses remaining in the plate after one cycle of thermal loading. (Auth.)

  2. Thermal stratification and fatigue stress analysis for pressurizer surge line

    International Nuclear Information System (INIS)

    Yu Xiaofei; Zhang Yixiong

    2011-01-01

    Thermal stratification of pressurizer surge line induced by the inside fluid results in the global bending moments, local thermal stresses, unexpected displacements and support loadings of the pipe system. In order to avoid a costly three-dimensional computation, a combined 1D/2D technique has been developed and implemented to analyze the thermal stratification and fatigue stress of pressurize surge line of QINSHAN Phase II Extension Nuclear Power Project in this paper, using the computer codes SYSTUS and ROCOCO. According to the mechanical analysis results of stratification, the maximum stress and cumulative usage factor are obtained. The results indicate that the stress and fatigue intensity considering thermal stratification satisfies RCC-M criterion. (authors)

  3. Blade dynamic stress analysis of rotating bladed disks

    Directory of Open Access Journals (Sweden)

    Kellner J.

    2007-10-01

    Full Text Available The paper deals with mathematical modelling of steady forced bladed disk vibrations and with dynamic stress calculation of the blades. The blades are considered as 1D kontinuum elastic coupled with three-dimensional elastic disk centrally clamped into rotor rotating with constant angular speed. The steady forced vibrations are generated by the aerodynamic forces acting along the blade length. By using modal synthesis method the mathematical model of the rotating bladed disk is condensed to calculate steady vibrations. Dynamic stress analysis of the blades is based on calculation of the time dependent reduced stress in blade cross-sections by using Hubert-Misses-Hencky stress hypothesis. The presented method is applied to real turbomachinery rotor with blades connected on the top with shroud.

  4. Stress analysis of aspherical coated particle with inner pressure

    Energy Technology Data Exchange (ETDEWEB)

    Liu Bing, E-mail: bingliu@tsinghua.edu.cn [Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing, 100084 (China); Yang Lin; Liang Tongxiang; Tang Chunhe [Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing, 100084 (China)

    2012-10-15

    Coated particles used in HTR fuel element sustain the inner pressure during irradiation as a pressure vessel. In actually the coated particle is not real spherical but with some asphericity, the stress distribution in the vessel is not uniform, coated layer in aspherical particle sustain more additional stress due to the asphericity. In this paper, the geometric shape distribution is summarized based on actual coated particle statistic. A mechanical analysis model is proposed for SiC layer by geometric combinations, and stress distribution of coated particle with a flat is calculated. The results show that the local maximum stress of aspherical particle increased two times than that of ideal spherical coated particle, which increase the failure probability under irradiation and high temperature.

  5. US Food and Drug Administration Pooled Analysis to Assess the Impact of Bone-Only Metastatic Breast Cancer on Clinical Trial Outcomes and Radiographic Assessments.

    Science.gov (United States)

    Wedam, Suparna B; Beaver, Julia A; Amiri-Kordestani, Laleh; Bloomquist, Erik; Tang, Shenghui; Goldberg, Kirsten B; Sridhara, Rajeshwari; Ibrahim, Amna; Kim, Geoffrey; Kluetz, Paul; McKee, Amy; Pazdur, Richard

    2018-04-20

    Purpose The outcome and proportion of patients with bone-only (BO) metastatic breast cancer (MBC) has not been well described. We sought to describe the differential outcomes of patients with BO MBC in clinical trials and explore whether there was a discrepancy in radiographic reads between investigator and blinded independent central review. Methods We pooled and analyzed data on 10,521 patients from 13 prospective trials submitted for MBC treatment in initial or supplemental New Drug or Biologics License Applications from 2005. Three subsets were evaluated: BO, bone with other metastases (BWO), and no bone metastases (NBM). Early discordance rate and late discordance rate were calculated from 3,733 and 2,813 patients subject to a blinded independent central review, respectively. Results Bone metastases were identified in 49% (range: 42% to 73%) of patients across trials. BO disease was present in 12.5% (range: 4% to 26%), dependent on subtype. Investigator-assessed progression-free survival (PFS) and overall survival (OS) for the pooled trials demonstrated improved outcomes for the BO subgroup compared with other subgroups (BO v BWO PFS hazard ratio [HR], 0.64; 95% CI, 0.591 to 0.696; BO v NBM PFS HR, 0.70; 95% CI, 0.65 to 0.76; BO v BWO OS HR, 0.56; 95% CI, 0.50 to 0.61; BO v NBM OS HR, 0.68; 95% CI, 0.61 to 0.76). The BO subgroup has a higher early discordance rate and lower late discordance rate than the BWO and NBM subgroups. Conclusion To our knowledge, this review is the largest analysis to date of the BO subgroup of MBC and suggests this subgroup may have a distinct natural history. There also seems to be a difference in how the local investigators assessed progression events in the BO subgroup when compared with the other two groups.

  6. Image decomposition as a tool for validating stress analysis models

    Directory of Open Access Journals (Sweden)

    Mottershead J.

    2010-06-01

    Full Text Available It is good practice to validate analytical and numerical models used in stress analysis for engineering design by comparison with measurements obtained from real components either in-service or in the laboratory. In reality, this critical step is often neglected or reduced to placing a single strain gage at the predicted hot-spot of stress. Modern techniques of optical analysis allow full-field maps of displacement, strain and, or stress to be obtained from real components with relative ease and at modest cost. However, validations continued to be performed only at predicted and, or observed hot-spots and most of the wealth of data is ignored. It is proposed that image decomposition methods, commonly employed in techniques such as fingerprinting and iris recognition, can be employed to validate stress analysis models by comparing all of the key features in the data from the experiment and the model. Image decomposition techniques such as Zernike moments and Fourier transforms have been used to decompose full-field distributions for strain generated from optical techniques such as digital image correlation and thermoelastic stress analysis as well as from analytical and numerical models by treating the strain distributions as images. The result of the decomposition is 101 to 102 image descriptors instead of the 105 or 106 pixels in the original data. As a consequence, it is relatively easy to make a statistical comparison of the image descriptors from the experiment and from the analytical/numerical model and to provide a quantitative assessment of the stress analysis.

  7. An exploratory study of radiographer's perceptions of radiographer commenting on musculo-skeletal trauma images in rural community based hospitals

    International Nuclear Information System (INIS)

    Howard, Morag L.

    2013-01-01

    Aim: This study sought to explore the perceptions of community hospital based radiographers in North East Scotland regarding the practice of radiographer commenting on musculo-skeletal trauma images. Method: A purposive sample of radiographers (n = 8) were recruited from community hospitals throughout the North-east of Scotland. A qualitative, exploratory study was conducted employing semi-structured interviews consisting of one focus group and two individual interviews. The interviews were audio recorded and transcribed in full to allow thematic analysis of the data using a framework adapted from Pope and Mays (2006). Main findings: This study revealed that the practice of radiographer commenting in the community provides a valuable front line opinion on musculo-skeletal trauma image appearances to enhance diagnostic outcomes for patients and streamline their care pathway. The appreciation shown from inter-professional colleagues for this practice induced feelings of professional pride and job satisfaction in the sample group. All participants expressed a desire to undertake additional training to allow progression from radiographer commenting to radiographer reporting of musculo-skeletal trauma images. Perceived barriers to the practice of radiographer commenting were time constraints and a lack of support with regards to continuing professional development (CPD) opportunities and mentorship from radiology colleagues. Conclusion: The practice of radiographer commenting in the community setting should be supported by ongoing training, and radiologist involvement in mentoring could provide radiographers with a valuable support mechanism. The voice of all radiographers regarding this extended role must be heard by professional leaders to ensure that the skills and education required for radiographer commenting are provided and subsequent patient care is not compromised

  8. Experimental stress analysis for determination of residual stresses and integrity monitoring of components and systems

    International Nuclear Information System (INIS)

    1993-01-01

    For an analysis of the safety-related significance of residual stresses, mechanical, magnetic as well as ultrasonic and diffraction methods can be applied as testing methods. The results of an interlaboratory test concerning the experimental determination of residual stresses in a railway track are included. Further, questions are analyzed concerning the in-service inspections of components and systems with regard to their operational safety and life. Measurement methods are explained by examples from power plant engineering, nuclear power plant engineering, construction and traffic engineering as well as aeronautics. (DG) [de

  9. Diffraction stress analysis of thin films; investigating elastic grain interaction

    International Nuclear Information System (INIS)

    Kumar, A.

    2005-12-01

    This work is dedicated to the investigation of specimens exhibiting anisotropic microstructures (and thus macroscopic elastic anisotropy) and/or inhomogeneous microstructures, as met near surfaces and in textured materials. The following aspects are covered: (i) Analysis of specimens with direction-dependent (anisotropic) elastic grain-interaction. Elastic grain-interaction determines the distribution of stresses and strains over the (crystallographically) differently oriented grains of a mechanically stressed polycrystal and the mechanical and diffraction (X-ray) elastic constants (relating (diffraction) lattice strains to mechanical stresses). Grain interaction models that allow for anisotropic, direction-dependent grain interaction have been developed very recently. The notion 'direction-dependent' grain-interaction signifies that different grain-interaction constraints prevail along different directions in a specimen. Practical examples of direction-dependent grain interaction are the occurrence of surface anisotropy in thin films and the surface regions of bulk polycrystals and the occurrence of grain-shape (morphological) texture. In this work, for the first time, stress analyses of thin films have been performed on the basis of these newly developed grain-interaction models. It has also been demonstrated that the identification of the (dominant) source of direction-dependent grain interaction is possible. The results for the grain interaction have been discussed in the light of microstructural investigations of the specimens by microscopic techniques. (ii) Analysis of specimens with depth gradients: Diffraction stress analysis can be hindered if gradients of the stress state, the composition or the microstructure occur in the specimen under investigation, as the so-called information depth varies in the course of a traditional stress measurement: Ambiguous results are thus generally obtained. In this work, a strategy for stress measurements at fixed

  10. Odontogenic keratocyst radiographic features

    International Nuclear Information System (INIS)

    Nartey, N. O.; Saini, T.

    1990-01-01

    The clinical features often patients with odontogenic keratocysts were studied. One patient had Gorlin-GoJtz syndrome. A total of fourteen radiolucent lesions were observed on radiographic examination. All the fourteen lesions were diagnosed as odontogenic keratocyst after histopathclogical examination of biopsied tissue from the patients. The age at diagnosis ranged from 25-72 years with a mean age of 37.6 years. The male : female ratio was 2.3:1. Thirteen of these lesions occurred in the mandible, nine involved the mandibular third molar region. Involvement of the ramus of the mandible produced a sausage-shaped radiolucency. Cystic lesions which have been present for long periods of time showed scalloped margins, due to the regional resorption of the surrounding bone. The bony ledges present on the cortical bones simulated multilocular appearance in such cases. It was also observed that the lesions in older individuals perforated the cortical plates rather than eliciting a periostally induced bony expansion. (author)

  11. A radiographic examination system

    International Nuclear Information System (INIS)

    Cable, A.P.; Cable, W.S.

    1983-01-01

    A system for performing radiographic examination, particularly of large items such as international container units is disclosed. The system is formed as an installation comprising housings for respective linear accelerators transmitting a beam of radiation across the path of a conveyor along which the units can be displaced continuously or incrementally. On either end of the installation are container handling areas including roller conveyors with drag chains and transverse manipulators, and the whole installation is secured within automatically operated doors which seal the high energy region when a container on the conveyor is being subjected to examination. The radiation transmitted through a container is detected in a detector system incorporating a fluoroscopic screen light output from which is detected in a camera system such as a television camera, and transmitted as coded pulsed signals by a coding transfer unit to display screens where an image of the transmitted information can be displayed and/or recorded for further use. (author)

  12. Radiographic contrast media

    International Nuclear Information System (INIS)

    Golman, K.; Holtz, E.; Almen, T.

    1987-01-01

    Contrast media are used in diagnostic radiology to enhance the X-ray attenuation between a body structure of interest and the surrounding tissue. A detail becomes perceptible on a roentgenogram only when its contrast exceeds a minimum value in relation to the background. Small areas of interest must have higher contrast than the background. The contrast effect depends on concentration of the contrast media with the body. A high contrast media concentration difference thus gives rise to more morphological details in the radiographs. Contrast media can be divided into negative contrast media such as air and gas which attenuate X-rays less than the body tissues, and positive contrast materials which attenuate X-rays more than the body tissues. The positive contrast media all contain either iodine (atomic number 53) or barium (atomic number 56) and can be divided into water-insoluble and water-soluble contrast media

  13. Stress analysis and evaluation of a rectangular pressure vessel

    International Nuclear Information System (INIS)

    Rezvani, M.A.; Ziada, H.H.; Shurrab, M.S.

    1992-10-01

    This study addresses structural analysis and evaluation of an abnormal rectangular pressure vessel, designed to house equipment for drilling and collecting samples from Hanford radioactive waste storage tanks. It had to be qualified according to ASME boiler and pressure vessel code, Section VIII; however, it had the cover plate bolted along the long face, a configuration not addressed by the code. Finite element method was used to calculate stresses resulting from internal pressure; these stresses were then used to evaluate and qualify the vessel. Fatigue is not a concern; thus, it can be built according to Section VIII, Division I instead of Division 2. Stress analysis was checked against the code. A stayed plate was added to stiffen the long side of the vessel

  14. Stress analysis of HTR-10 steam generator heat exchanging tubes

    International Nuclear Information System (INIS)

    Dong Jianling; Zhang Xiaohang; Yin Dejian; Fu Jiyang

    2001-01-01

    Steam Generator (SG) heat exchanging tubes of 10 MW High Temperature Gas Cooled Reactor (HTR-10) are protective screens between the primary loop of helium with radioactivity and the secondary loop of feeding water and steam without radioactivity. Water and steam will enter into the primary loop when rupture of the heat exchanging tubes occurs, which lead to increase of the primary loop pressure and discharge of radioactive materials. Therefore it is important to guarantee the integrity of the tubes. The tube structure is spiral tube with small bending radius, which make it impossible to test with volumetric in-service detection. For such kind of spiral tube, using LBB concept to guarantee the integrity of the tubes is an important option. The author conducts stress analysis and calculation of HTR-10 SG heat exchanging tubes using the FEM code of piping stress analysis, PIPESTRESS. The maximum stress and the dangerous positions are obtained

  15. incidence of occupational stress among medical radiographers

    African Journals Online (AJOL)

    which future studies in view of the on going health sector reform in Nigeria could be compared. Key Words: ... disturbing individual's well being physically and mentally (Akpa and .... not only mental health but also the ... Stressors and employee.

  16. Stress

    Science.gov (United States)

    ... can be life-saving. But chronic stress can cause both physical and mental harm. There are at least three different types of stress: Routine stress related to the pressures of work, family, and other daily responsibilities Stress brought about ...

  17. Midterm Clinical and Radiographic Results of Mobile-Bearing Revision Total Knee Arthroplasty.

    Science.gov (United States)

    Kim, Raymond H; Martin, J Ryan; Dennis, Douglas A; Yang, Charlie C; Jennings, Jason M; Lee, Gwo-Chin

    2017-06-01

    Constrained implants are frequently required in revision total knee arthroplasty (TKA) and are associated with an increase in aseptic component loosening and damage or wear to the constraining mechanisms, compared with primary TKA. The purpose of the following study was to evaluate the midterm clinical and radiographic results including the incidence of bearing complications in a group of patients undergoing revision TKA using mobile-bearing revision TKA implants. We retrospectively reviewed 316 consecutive mobile-bearing revision TKAs performed at 2 centers between 2006 and 2010. There were 183 women and 133 men with a mean age of 66 years. The patients were evaluated clinically using the Knee Society scores. A radiographic analysis was performed. Bearing specific complications (ie, instability or dislocation) were recorded. Patients were followed-up for a minimum of 24 months and a median of 59.88 months (range 24-121.2). The average Knee Society knee score and function scores increased from 40.8 and 47.9 points preoperatively to 80 points and 70.3 points, respectively (P bearing complications were observed. Revision TKA using mobile-bearing revision components demonstrated favorable midterm clinical and radiographic results with no occurrence of bearing instability or dislocation. Longer follow-up is required to evaluate for potential advantages of mobile-bearings over fixed-bearing revision components in terms of polyethylene wear reduction, reduced stress transmission across fixation interfaces, and reduced stress on the polyethylene post. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Residual stress analysis of drive shafts after induction hardening

    Energy Technology Data Exchange (ETDEWEB)

    Lemos, Guilherme Vieira Braga; Rocha, Alexandre da Silva; Nunes, Rafael Menezes, E-mail: lemos_gl@yahoo.com.br [Universidade Federal do Rio Grande do Sul (UFRS), Porto Algre, RS (Brazil); Hirsch, Thomas Karl [Stiftung Institut für Werkstofftechnik (IWT), Bremen (Germany)

    2014-08-15

    Typically, for automotive shafts, shape distortion manifests itself in most cases after the induction hardening by an effect known as bending. The distortion results in a boost of costs, especially due to machining parts in the hardened state to fabricate its final tolerances. In the present study, residual stress measurements were carried out on automotive drive shafts made of DIN 38B3 steel. The samples were selected in consequence of their different distortion properties by an industrial manufacturing line. One tested shaft was straightened, because of the considerable dimensional variation and the other one not. Firstly, the residual stress measurements were carried out by using a portable diffractometer, in order to avoid cutting the shafts and evaluate the original state of the stresses, and afterwards a more detailed analysis was realized by a conventional stationary diffractometer. The obtained results presented an overview of the surface residual stress profiles after induction hardening and displayed the influence of the straightening process on the redistribution of residual stresses. They also indicated that the effects of the straightening in the residual stresses cannot be neglected. (author)

  19. Interpretation and digestion of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    Radiography digestion is final test for the radiography to make sure that radiograph produced will inspect their quality of the image before its interpreted. This level is critical level where if there is a mistake, all of the radiography work done before will be unaccepted. So as mention earlier, it can waste time, cost and more worst it can make the production must shut down. So, this step, level two radiographers or interpreter must evaluate the radiograph carefully. For this purpose, digestion room and densitometer must used. Of course all the procedure must follow the specification that mentioned in document. There are several needs must fill before we can say the radiograph is corrected or not like the location of penetrameter, number of penetrameter that showed, the degree of density of film, and usually there is no problem in this step and the radiograph can go to interpretation and evaluation step as will mentioned in next chapter.

  20. Chesneys' radiographic imaging. 5. ed.

    International Nuclear Information System (INIS)

    Ball, J.; Price, T.

    1989-01-01

    This new edition of Chesney and Chesney: Radiographic Imaging has been completely written by two new authors. The book reflects the change in emphasis in radiology from photographic processes towards electronic imaging methods. There is new material on image intensifiers and television imaging, digital imaging and digital subtractions. Analyses of the various characteristics of, and defects in, images on radiographs, xeroradiographs and the television screen are included. The methods, equipment and materials used to record the cathode ray tube image are described and there is new material on the principles of alternative diagnostic imaging techniques such as ultrasound, computed tomography and radionuclide imaging which provide cathode ray tube images. The book is primarily for student radiographers studying for the Diploma of the College of Radiographers, but radiographers studying for postdiplomate qualifications such as the Higher Diploma (HDCR) will also find the book helpful. (author)

  1. Heat transfer and thermal stress analysis in grooved tubes

    Indian Academy of Sciences (India)

    Heat transfer and thermal stresses, induced by temperature differencesin the internally grooved tubes of heat transfer equipment, have been analysed numerically. The analysis has been conducted for four different kinds of internally grooved tubes and three different mean inlet water velocities. Constant temperature was ...

  2. Analysis of stress and deformation in non-stationary creep

    International Nuclear Information System (INIS)

    Feijoo, R.A.; Taroco, E.; Guerreiro, J.N.C.

    1980-12-01

    A variational method and its algorithm are presented; they permit the analysis of stress and deformation in non-stationary creep. This algorithm is applied to an infinite cylinder submitted to an internal pressure. The solution obtained is compared with the solution of non-stationary creep problems [pt

  3. ITER vacuum vessel dynamic stress analysis of a disruption

    International Nuclear Information System (INIS)

    Riemer, B.W.; Conner, D.L.; Strickler, D.J.; Williamson, D.E.

    1994-01-01

    Dynamic stress analysis of the International Thermonuclear Experimental Reactor vacuum vessel loaded by disruption forces was performed. The deformation and stress results showed strong inertial effects when compared to static analyses. Maximum stress predicted dynamically was 300 MPa, but stress shown by static analysis from loads at the same point in time reached only 80 MPa. The analysis also provided a reaction load history in the vessel's supports which is essential in evaluating support design. The disruption forces were estimated by assuming a 25-MA plasma current decaying at 1 MA/ms while moving vertically. In addition to forces developed within the vessel, vertical loadings from the first wall/strong back assemblies and the divertor were applied to the vessel at their attachment points. The first 50 natural modes were also determined. The first mode's frequency was 6.0 Hz, and its shape is characterized by vertical displacement of the vessel inner leg. The predicted deformation of the vessel appeared similar to its first mode shape combined with radial contraction. Kinetic energy history from the analysis also correlated with the first mode frequency

  4. Contact stress analysis of involute spur gear by Finite Element ...

    African Journals Online (AJOL)

    In this paper the contact stress in rolling-sliding contact of involute spur gear and the effect of coefficient of friction was analyzed. To achieve this, first, three dimensional involute spur gear pairs were developed in Solid works 2012 Premium and the 3D model was exported to ANSYS workbench 14.5. Next, the analysis was ...

  5. The Psychophysiology of Posttraumatic Stress Disorder: A Meta-Analysis

    Science.gov (United States)

    Pole, Nnamdi

    2007-01-01

    This meta-analysis of 58 resting baseline studies, 25 startle studies, 17 standardized trauma cue studies, and 22 idiographic trauma cue studies compared adults with and without posttraumatic stress disorder (PTSD) on psychophysiological variables: facial electromyography (EMG), heart rate (HR), skin conductance (SC), and blood pressure.…

  6. Image rejects/retakes--radiographic challenges.

    Science.gov (United States)

    Waaler, D; Hofmann, B

    2010-01-01

    A general held position among radiological personnel prior to digitalisation was that the problem of image rejects/retakes should more or less vanish. However, rejects/retakes still impose several challenges within radiographic imaging; they occupy unnecessary resources, expose patients to unnecessary ionizing radiation and may also indicate suboptimal quality management. The latter is the main objective of this paper, which is based on a survey of international papers published both for screen/film and digital technology. The digital revolution in imaging seems to have reduced the percentage of image rejects/retakes from 10-15 to 3-5 %. The major contribution to the decrease appears to be the dramatic reduction of incorrect exposures. At the same time, rejects/retakes due to lack of operator competence (positioning, etc.) are almost unchanged, or perhaps slightly increased (due to lack of proper technical competence, incorrect organ coding, etc.). However, the causes of rejects/retakes are in many cases defined and reported with reference to radiographers' subjective evaluations. Thus, unless radiographers share common views on image quality and acceptance criteria, objective measurements and assessments of reject/retake rates are challenging tasks. Interestingly, none of the investigated papers employs image quality parameters such as 'too much noise' as categories for rejects/retakes. Surprisingly, no reject/retake analysis seems yet to have been conducted for direct digital radiography departments. An increased percentage of rejects/retakes is related to 'digital skills' of radiographers and therefore points to areas for extended education and training. Furthermore, there is a need to investigate the inter-subjectivity of radiographers' perception of, and attitude towards, both technical and clinical image quality criteria. Finally, there may be a need to validate whether reject/retake rate analysis is such an effective quality indicator as has been asserted.

  7. Image rejects/retakes-radiographic challenges

    International Nuclear Information System (INIS)

    Waaler, D.; Hofmann, B.

    2010-01-01

    A general held position among radiological personnel prior to digitalisation was that the problem of image rejects/retakes should more or less vanish. However, rejects/retakes still impose several challenges within radiographic imaging; they occupy unnecessary resources, expose patients to unnecessary ionizing radiation and may also indicate suboptimal quality management. The latter is the main objective of this paper, which is based on a survey of international papers published both for screen/film and digital technology. The digital revolution in imaging seems to have reduced the percentage of image rejects/retakes from 10-15 to 3-5%. The major contribution to the decrease appears to be the dramatic reduction of incorrect exposures. At the same time, rejects/retakes due to lack of operator competence (positioning, etc.) are almost unchanged, or perhaps slightly increased (due to lack of proper technical competence, incorrect organ coding, etc.). However, the causes of rejects/retakes are in many cases defined and reported with reference to radiographers' subjective evaluations. Thus, unless radiographers share common views on image quality and acceptance criteria, objective measurements and assessments of reject/retake rates are challenging tasks. Interestingly, none of the investigated papers employs image quality parameters such as 'too much noise' as categories for rejects/retakes. Surprisingly, no reject/retake analysis seems yet to have been conducted for direct digital radiography departments. An increased percentage of rejects/retakes is related to 'digital skills' of radiographers and therefore points to areas for extended education and training. Furthermore, there is a need to investigate the inter subjectivity of radiographers' perception of, and attitude towards, both technical and clinical image quality criteria. Finally, there may be a need to validate whether reject/retake rate analysis is such an effective quality indicator as has been asserted

  8. Detecting objects in radiographs for homeland security

    Science.gov (United States)

    Prasad, Lakshman; Snyder, Hans

    2005-05-01

    We present a general scheme for segmenting a radiographic image into polygons that correspond to visual features. This decomposition provides a vectorized representation that is a high-level description of the image. The polygons correspond to objects or object parts present in the image. This characterization of radiographs allows the direct application of several shape recognition algorithms to identify objects. In this paper we describe the use of constrained Delaunay triangulations as a uniform foundational tool to achieve multiple visual tasks, namely image segmentation, shape decomposition, and parts-based shape matching. Shape decomposition yields parts that serve as tokens representing local shape characteristics. Parts-based shape matching enables the recognition of objects in the presence of occlusions, which commonly occur in radiographs. The polygonal representation of image features affords the efficient design and application of sophisticated geometric filtering methods to detect large-scale structural properties of objects in images. Finally, the representation of radiographs via polygons results in significant reduction of image file sizes and permits the scalable graphical representation of images, along with annotations of detected objects, in the SVG (scalable vector graphics) format that is proposed by the world wide web consortium (W3C). This is a textual representation that can be compressed and encrypted for efficient and secure transmission of information over wireless channels and on the Internet. In particular, our methods described here provide an algorithmic framework for developing image analysis tools for screening cargo at ports of entry for homeland security.

  9. Stress analysis in oral obturator prostheses, part II: photoelastic imaging

    Science.gov (United States)

    Pesqueira, Aldiéris Alves; Goiato, Marcelo Coelho; da Silva, Emily Vivianne Freitas; Haddad, Marcela Filié; Moreno, Amália; Zahoui, Abbas; dos Santos, Daniela Micheline

    2014-06-01

    In part I of the study, two attachment systems [O-ring; bar-clip (BC)] were used, and the system with three individualized O-rings provided the lowest stress on the implants and the support tissues. Therefore, the aim of this study was to assess the stress distribution, through the photoelastic method, on implant-retained palatal obturator prostheses associated with different attachment systems: BOC-splinted implants with a bar connected to two centrally placed O-rings, and BOD-splinted implants with a BC connected to two distally placed O-rings (cantilever). One photoelastic model of the maxilla with oral-sinus-nasal communication with three parallel implants was fabricated. Afterward, two implant-retained palatal obturator prostheses with the two attachment systems described above were constructed. Each assembly was positioned in a circular polariscope and a 100-N axial load was applied in three different regions with implants by using a universal testing machine. The results were obtained through photograph record analysis of stress. The BOD system exhibited the highest stress concentration, followed by the BOC system. The O-ring, centrally placed on the bar, allows higher mobility of the prostheses and homogeneously distributes the stress to the region of the alveolar ridge and implants. It can be concluded that the use of implants with O-rings, isolated or connected with a bar, to rehabilitate maxillectomized patients allows higher prosthesis mobility and homogeneously distributes the stress to the alveolar ridge region, which may result in greater chewing stress distribution to implants and bone tissue. The clinical implication of the augmented bone support loss after maxillectomy is the increase of stress in the attachment systems and, consequently, a higher tendency for displacement of the prosthesis.

  10. Transcriptomic analysis of salt stress responsive genes in Rhazya stricta.

    Directory of Open Access Journals (Sweden)

    Nahid H Hajrah

    Full Text Available Rhazya stricta is an evergreen shrub that is widely distributed across Western and South Asia, and like many other members of the Apocynaceae produces monoterpene indole alkaloids that have anti-cancer properties. This species is adapted to very harsh desert conditions making it an excellent system for studying tolerance to high temperatures and salinity. RNA-Seq analysis was performed on R. stricta exposed to severe salt stress (500 mM NaCl across four time intervals (0, 2, 12 and 24 h to examine mechanisms of salt tolerance. A large number of transcripts including genes encoding tetrapyrroles and pentatricopeptide repeat (PPR proteins were regulated only after 12 h of stress of seedlings grown in controlled greenhouse conditions. Mechanisms of salt tolerance in R. stricta may involve the upregulation of genes encoding chaperone protein Dnaj6, UDP-glucosyl transferase 85a2, protein transparent testa 12 and respiratory burst oxidase homolog protein b. Many of the highly-expressed genes act on protecting protein folding during salt stress and the production of flavonoids, key secondary metabolites in stress tolerance. Other regulated genes encode enzymes in the porphyrin and chlorophyll metabolic pathway with important roles during plant growth, photosynthesis, hormone signaling and abiotic responses. Heme biosynthesis in R. stricta leaves might add to the level of salt stress tolerance by maintaining appropriate levels of photosynthesis and normal plant growth as well as by the participation in reactive oxygen species (ROS production under stress. We speculate that the high expression levels of PPR genes may be dependent on expression levels of their targeted editing genes. Although the results of PPR gene family indicated regulation of a large number of transcripts under salt stress, PPR actions were independent of the salt stress because their RNA editing patterns were unchanged.

  11. Thermal stress analysis of a planar SOFC stack

    Science.gov (United States)

    Lin, Chih-Kuang; Chen, Tsung-Ting; Chyou, Yau-Pin; Chiang, Lieh-Kwang

    The aim of this study is, by using finite element analysis (FEA), to characterize the thermal stress distribution in a planar solid oxide fuel cell (SOFC) stack during various stages. The temperature profiles generated by an integrated thermo-electrochemical model were applied to calculate the thermal stress distributions in a multiple-cell SOFC stack by using a three-dimensional (3D) FEA model. The constructed 3D FEA model consists of the complete components used in a practical SOFC stack, including positive electrode-electrolyte-negative electrode (PEN) assembly, interconnect, nickel mesh, and gas-tight glass-ceramic seals. Incorporation of the glass-ceramic sealant, which was never considered in previous studies, into the 3D FEA model would produce more realistic results in thermal stress analysis and enhance the reliability of predicting potential failure locations in an SOFC stack. The effects of stack support condition, viscous behavior of the glass-ceramic sealant, temperature gradient, and thermal expansion mismatch between components were characterized. Modeling results indicated that a change in the support condition at the bottom frame of the SOFC stack would not cause significant changes in thermal stress distribution. Thermal stress distribution did not differ significantly in each unit cell of the multiple-cell stack due to a comparable in-plane temperature profile. By considering the viscous characteristics of the glass-ceramic sealant at temperatures above the glass-transition temperature, relaxation of thermal stresses in the PEN was predicted. The thermal expansion behavior of the metallic interconnect/frame had a greater influence on the thermal stress distribution in the PEN than did that of the glass-ceramic sealant due to the domination of interconnect/frame in the volume of a planar SOFC assembly.

  12. Stress analysis of closure bolts for shipping casks

    International Nuclear Information System (INIS)

    Mok, G.C.; Fischer, L.E.; Hsu, S.T.

    1993-01-01

    This report specifies the requirements and criteria for stress analysis of closure bolts for shipping casks containing nuclear spent fuels or high level radioactive materials. The specification is based on existing information conceming the structural behavior, analysis, and design of bolted joints. The approach taken was to extend the ASME Boiler and Pressure Vessel Code requirements and criteria for bolting analysis of nuclear piping and pressure vessels to include the appropriate design and load characteristics of the shipping cask. The characteristics considered are large, flat, closure lids with metal-to-metal contact within the bolted joint; significant temperature and impact loads; and possible prying and bending effects. Specific formulas and procedures developed apply to the bolt stress analysis of a circular, flat, bolted closure. The report also includes critical load cases and desirable design practices for the bolted closure, an in-depth review of the structural behavior of bolted joints, and a comprehensive bibliography of current information on bolted joints

  13. Comparative proteomic analysis in Miscanthus sinensis exposed to antimony stress

    International Nuclear Information System (INIS)

    Xue, Liang; Ren, Huadong; Li, Sheng; Gao, Ming; Shi, Shengqing; Chang, Ermei; Wei, Yuan; Yao, Xiaohua; Jiang, Zeping; Liu, Jianfeng

    2015-01-01

    To explore the molecular basis of Sb tolerance mechanism in plant, a comparative proteomic analysis of both roots and leaves in Miscanthus sinensis has been conducted in combination with physiological and biochemical analyses. M. sinensis seedlings were exposed to different doses of Sb, and both roots and leaves were collected after 3 days of treatment. Two-dimensional gel electrophoresis (2-DE) and image analyses found that 29 protein spots showed 1.5-fold change in abundance in leaves and 19 spots in roots, of which 31 were identified by MALDI-TOF-MS and MALDI-TOF-TOF-MS. Proteins involved in antioxidant defense and stress response generally increased their expression all over the Sb treatments. In addition, proteins relative to transcription, signal transduction, energy metabolism and cell division and cell structure showed a variable expression pattern over Sb concentrations. Overall these findings provide new insights into the probable survival mechanisms by which M. sinensis could be adapting to Sb phytotoxicity. - Highlights: • Proteomics in Miscanthus sinensis leaves and roots exposed to Sb stress were studied. • There were 31 spots that were identified by mass spectrometry. • Most of these proteins were involved in antioxidant defense and stress response. • Our findings provide new insights into the tolerant mechanisms to Sb stress. - Miscanthus sinensis proteomic analysis under Sb stress reveals probable molecular mechanisms on Sb detoxification

  14. Comparison of codes and standards for radiographic inspection

    International Nuclear Information System (INIS)

    Bingoeldag, M. M.; Aksu, M.; Akguen, A. F.

    1995-01-01

    This report compares the procedurel requirements and acceptance criteria for radiographic inspections specified in the relevant national and international codes and standards. In particular, detailed analysis of inspection conditions such as exposure arrangements, and contrast requirements are given

  15. Dynamical System Analysis of Reynolds Stress Closure Equations

    Science.gov (United States)

    Girimaji, Sharath S.

    1997-01-01

    In this paper, we establish the causality between the model coefficients in the standard pressure-strain correlation model and the predicted equilibrium states for homogeneous turbulence. We accomplish this by performing a comprehensive fixed point analysis of the modeled Reynolds stress and dissipation rate equations. The results from this analysis will be very useful for developing improved pressure-strain correlation models to yield observed equilibrium behavior.

  16. Stress analysis of heated concrete using finite elements

    International Nuclear Information System (INIS)

    Majumdar, P.; Gupta, A.; Marchertas, A.

    1994-01-01

    Described is a finite element analysis of concrete, which is subjected to rapid heating. Using thermal mass transport calculation, the moisture content, temperature and pore pressure distribution over space and time is obtained first. From these effects, stress at various points of the concrete are computed using the finite element method. Contribution to the stress formulation comes from three components, namely the thermal expansion, pore pressure, and the shrinkage of concrete due to moisture loss (from dehydration). The material properties of concrete are assumed to be homogeneous, elastic, and cracking is not taken into consideration. (orig.)

  17. A multimodal stress monitoring system with canonical correlation analysis.

    Science.gov (United States)

    Unsoo Ha; Changhyeon Kim; Yongsu Lee; Hyunki Kim; Taehwan Roh; Hoi-Jun Yoo

    2015-08-01

    The multimodal stress monitoring headband is proposed for mobile stress management system. It is composed of headband and earplugs. Electroencephalography (EEG), hemoencephalography (HEG) and heart-rate variability (HRV) can be achieved simultaneously in the proposed system for user status estimation. With canonical correlation analysis (CCA) and temporal-kernel CCA (tkCCA) algorithm, those different signals can be combined for maximum correlation. Thanks to the proposed combination algorithm, the accuracy of the proposed system increased up to 19 percentage points than unimodal monitoring system in n-back task.

  18. Regular and platform switching: bone stress analysis varying implant type.

    Science.gov (United States)

    Gurgel-Juarez, Nália Cecília; de Almeida, Erika Oliveira; Rocha, Eduardo Passos; Freitas, Amílcar Chagas; Anchieta, Rodolfo Bruniera; de Vargas, Luis Carlos Merçon; Kina, Sidney; França, Fabiana Mantovani Gomes

    2012-04-01

    This study aimed to evaluate stress distribution on peri-implant bone simulating the influence of platform switching in external and internal hexagon implants using three-dimensional finite element analysis. Four mathematical models of a central incisor supported by an implant were created: External Regular model (ER) with 5.0 mm × 11.5 mm external hexagon implant and 5.0 mm abutment (0% abutment shifting), Internal Regular model (IR) with 4.5 mm × 11.5 mm internal hexagon implant and 4.5 mm abutment (0% abutment shifting), External Switching model (ES) with 5.0 mm × 11.5 mm external hexagon implant and 4.1 mm abutment (18% abutment shifting), and Internal Switching model (IS) with 4.5 mm × 11.5 mm internal hexagon implant and 3.8 mm abutment (15% abutment shifting). The models were created by SolidWorks software. The numerical analysis was performed using ANSYS Workbench. Oblique forces (100 N) were applied to the palatal surface of the central incisor. The maximum (σ(max)) and minimum (σ(min)) principal stress, equivalent von Mises stress (σ(vM)), and maximum principal elastic strain (ε(max)) values were evaluated for the cortical and trabecular bone. For cortical bone, the highest stress values (σ(max) and σ(vm) ) (MPa) were observed in IR (87.4 and 82.3), followed by IS (83.3 and 72.4), ER (82 and 65.1), and ES (56.7 and 51.6). For ε(max), IR showed the highest stress (5.46e-003), followed by IS (5.23e-003), ER (5.22e-003), and ES (3.67e-003). For the trabecular bone, the highest stress values (σ(max)) (MPa) were observed in ER (12.5), followed by IS (12), ES (11.9), and IR (4.95). For σ(vM), the highest stress values (MPa) were observed in IS (9.65), followed by ER (9.3), ES (8.61), and IR (5.62). For ε(max) , ER showed the highest stress (5.5e-003), followed by ES (5.43e-003), IS (3.75e-003), and IR (3.15e-003). The influence of platform switching was more evident for cortical bone than for trabecular bone, mainly for the external hexagon

  19. Composite Analysis of Concrete - Creep, Relaxation and Eigenstrain/stress

    DEFF Research Database (Denmark)

    Nielsen, Lauge Fuglsang

    1996-01-01

    approach.The model is successfully justified comparing predicted results with recent experimental data obtained in tests made at the Danish Technological Institute and at the Technical University of Denmark on creep, relaxation, and shrinkage of very young concretes (hours) - and also with experimental...... results on creep, shrinkage, and internal stresses caused by drying shrinkage reported in the literature on the mechanical behavior of mature concretes.Shrinkage (autogeneous or drying) of mortar and concrete and associated internal stress states are examples of analysis made in this report......A composite-rheological model of concrete is presented by which consistent predictions of creep, relaxation, and internal stresses can be made from known concrete composition, age at loading, and climatic conditions. No other existing "creep prediction method" offers these possibilities in one...

  20. Micromechanical combined stress analysis: MICSTRAN, a user manual

    Science.gov (United States)

    Naik, R. A.

    1992-01-01

    Composite materials are currently being used in aerospace and other applications. The ability to tailor the composite properties by the appropriate selection of its constituents, the fiber and matrix, is a major advantage of composite materials. The Micromechanical Combined Stress Analysis (MICSTRAN) code provides the materials engineer with a user-friendly personal computer (PC) based tool to calculate overall composite properties given the constituent fiber and matrix properties. To assess the ability of the composite to carry structural loads, the materials engineer also needs to calculate the internal stresses in the composite material. MICSTRAN is a simple tool to calculate such internal stresses with a composite ply under combined thermomechanical loading. It assumes that the fibers have a circular cross-section and are arranged either in a repeating square or diamond array pattern within a ply. It uses a classical elasticity solution technique that has been demonstrated to calculate accurate stress results. Input to the program consists of transversely isotropic fiber properties and isotropic matrix properties such as moduli, Poisson's ratios, coefficients of thermal expansion, and volume fraction. Output consists of overall thermoelastic constants and stresses. Stresses can be computed under the combined action of thermal, transverse, longitudinal, transverse shear, and longitudinal shear loadings. Stress output can be requested along the fiber-matrix interface, the model boundaries, circular arcs, or at user-specified points located anywhere in the model. The MICSTRAN program is Windows compatible and takes advantage of the Microsoft Windows graphical user interface which facilitates multitasking and extends memory access far beyond the limits imposed by the DOS operating system.

  1. Stress analysis in a non axisymmetric loaded reactor pressure vessel

    International Nuclear Information System (INIS)

    Albuquerque, Levi Barcelos; Assis, Gracia Menezes V. de; Miranda, Carlos Alexandre J.; Cruz, Julio Ricardo B.; Mattar Neto, Miguel

    1995-01-01

    In this work we intend to present the stress analysis of a PWR vessel under postulated concentrated loads. The vessel was modeled with Axisymmetric solid 4 nodes harmonic finite elements with the use of the ANSYS program, version 5.0. The bolts connecting the vessel flanges were modeled with beam elements. Some considerations were made to model the contact between the flanges. The perforated part of the vessel tori spherical head was modeled (with reduced properties due to its holes) to introduce its stiffness and loads but was not within the scope of this work. The loading consists of some usual ones, as pressure, dead weight, bolts preload, seismic load and some postulated ones as concentrated loads, over the vessel, modeled by Fourier Series. The results in the axisymmetric model are taken in terms of linearized stresses, obtained in some circumferential positions and for each position, in some sections along the vessel. Using the ASME Code (Section III, Division 1, Sub-section NB) the stresses are within the allowable limits. In order to draw some conclusions about stress linearization, the membrane plus bending stresses (Pl + Pb) are obtained and compared in some sections, using three different methods. (author)

  2. The impact of patient global assessment in the definition of remission as a predictor of long-term radiographic damage in patients with rheumatoid arthritis: protocol for an individual patient data meta-analysis

    Directory of Open Access Journals (Sweden)

    Ricardo J.O. Ferreira

    2018-01-01

    Full Text Available Background: Remission is the target for management of rheumatoid arthritis (RA and intensification of immunosuppressive therapy is recommended for those that do not achieve this status. Patient global assessment (PGA is the single patient reported outcome considered in the American College of Rheumatology/European League Against Rheumatism remission criteria, but its use as target has been questioned. The primary aim of this study is to assess whether excluding PGA from the definition of disease remission changes the association of disease remission with long-term radiographic damage and physical function in patients with RA. Methods: Individual Patient Data Meta-analysis using data from randomized controlled trials of biological and targeted synthetic agents, identified through ClinicalTrials.gov and PubMed. Different remission states will be defined: (i 4v-remission [tender (TJC28 and swollen 28-joint counts (SJC28 both≤1, C-reactive protein (CRP≤1 (mg/dl, and PGA≤1 (0-10 scale], (ii 4v-near-remission (TJC28≤1, SJC28≤1, CRP≤1, and PGA>1, (iii non-remission (TJC28>1 or SJC28>1 or CRP>1, all mutually exclusive, and (iv 3v-remission (TJC28≤1, SJC28≤1, CRP≤1. Likelihood ratios will be used to descriptively compare whether meeting the 3v and 4v-remission criteria in a single visit (at 6 or 12 months predicts good outcome in the second year (1-2y. Differences in the predictive value of PGA in the definition of remission will be assessed by comparing the three mutually exclusive disease states using logistic regression analysis. Good outcome is defined primarily by radiographic damage (no deterioration in radiographic scores, whatever the instrument used in each trial, and secondarily by functional disability (Health Assessment Questionnaire consistently ≤0.5 and no deterioration, and their combination (“overall good outcome”. Additional analyses will consider longer periods over which to (concurrently define remission status

  3. Radiographic scanner apparatus

    International Nuclear Information System (INIS)

    Wake, R.H.

    1980-01-01

    The preferred embodiment of this invention includes a hardware system, or processing means, which operates faster than software. Moreover the computer needed is less expensive and smaller. Radiographic scanner apparatus is described for measuring the intensity of radiation after passage through a planar region and for reconstructing a representation of the attenuation of radiation by the medium. There is a source which can be rotated, and detectors, the output from which forms a data line. The detectors are disposed opposite the planar region from the source to produce a succession of data lines corresponding to the succession of angular orientations of the source. There is a convolver means for convolving each of these data lines, with a filter function, and a means of processing the convolved data lines to create the representation of the radiation attenuation in the planar region. There is also apparatus to generate a succession of data lines indicating radiation attenuation along a determinable path with convolver means. (U.K.)

  4. Joining U.S. NRC international round robin for weld residual stress analysis. Stress analysis and validation in PWSCC mitigation program

    International Nuclear Information System (INIS)

    Maekawa, Akira; Serizawa, Hisashi; Murakawa, Hidekazu

    2012-01-01

    It is necessary to establish properly reliable weld residual stress analysis methods for accurate crack initiation and growth assessment of primary water stress corrosion cracking (PWSCC), which may occur in nickel-based dissimilar metal welds in pressurized water reactors. The U.S. Nuclear Regulatory Commission conducted an international round robin for weld residual stress analysis to improve stress analysis methods and to examine the uncertainties involved in the calculated stress values. In this paper, the results from the authors' participation in the round robin were reported. In the round robin, the weld residual stress in a nickel-based dissimilar metal weld of a pressurizer surge nozzle mock-up was computed under various analysis conditions. Based on these residual stress analysis results, a welding simulation code currently being developed that uses the iterative substructure method was validated and affecting factors on the analysis results were identified. (author)

  5. Perception of health risks of electromagnetic fields by MRI radiographers and airport security officers compared to the general Dutch working population: a cross sectional analysis.

    Science.gov (United States)

    van Dongen, Diana; Smid, Tjabe; Timmermans, Daniëlle R M

    2011-11-09

    The amount of exposure to electromagnetic fields (EMF) at work is mainly determined by an individual's occupation and may differ from exposure at home. It is, however, unknown how different occupational groups perceive possible adverse health effects of EMF. Three occupational groups, the general Dutch working population (n = 567), airport security officers who work with metal detectors (n = 106), and MRI radiographers who work with MRI (n = 193), were compared on perceived risk of and positive and negative feelings towards EMF in general and of different EMF sources, and health concerns by using analyses of variances. Data were collected via an internet survey. Overall, MRI radiographers had a lower perceived risk, felt less negative, and more positive towards EMF and different sources of EMF than the general working population and the security officers. For security officers, feeling more positive about EMF was not significantly related to perceived risk of EMF in general or EMF of domestic sources. Feeling positive about a source did not generalize to a lower perceived risk, while negative feelings were stronger related to perceived risk. MRI radiographers had fewer health concerns regarding EMF than the other two groups, although they considered it more likely that EMF could cause physical complaints. These data show that although differences in occupation appear to be reflected in different perceptions of EMF, the level of occupational exposure to EMF as such does not predict the perceived health risk of EMF. © 2011 van Dongen et al; licensee BioMed Central Ltd.

  6. Perception of health risks of electromagnetic fields by MRI radiographers and airport security officers compared to the general Dutch working population: a cross sectional analysis

    Directory of Open Access Journals (Sweden)

    van Dongen Diana

    2011-11-01

    Full Text Available Abstract Background The amount of exposure to electromagnetic fields (EMF at work is mainly determined by an individual's occupation and may differ from exposure at home. It is, however, unknown how different occupational groups perceive possible adverse health effects of EMF. Methods Three occupational groups, the general Dutch working population (n = 567, airport security officers who work with metal detectors (n = 106, and MRI radiographers who work with MRI (n = 193, were compared on perceived risk of and positive and negative feelings towards EMF in general and of different EMF sources, and health concerns by using analyses of variances. Data were collected via an internet survey. Results Overall, MRI radiographers had a lower perceived risk, felt less negative, and more positive towards EMF and different sources of EMF than the general working population and the security officers. For security officers, feeling more positive about EMF was not significantly related to perceived risk of EMF in general or EMF of domestic sources. Feeling positive about a source did not generalize to a lower perceived risk, while negative feelings were stronger related to perceived risk. MRI radiographers had fewer health concerns regarding EMF than the other two groups, although they considered it more likely that EMF could cause physical complaints. Conclusions These data show that although differences in occupation appear to be reflected in different perceptions of EMF, the level of occupational exposure to EMF as such does not predict the perceived health risk of EMF.

  7. Main factors of efficiency of automated radiographic complex

    International Nuclear Information System (INIS)

    Akopov, V.S.; Voronin, S.A.; Grachev, A.V.; Golenishchev, I.A.; Majorov, A.N.; Meshalkin, I.A.

    1978-01-01

    The amount of work providing an assessment of the efficiency of a complex for automatized radiographic control is considered. The technique involves four stages. An analysis was performed to ascertain the efficiency of control of flaw detectability with regard to each of the stages of radiographic control. The relationships used in determining control efficiency and cited in the paper serve as a foundation for optimizing the technical parameters of the devices of the automatized complex and for creating calculation methods for generalized assessments of the efficiency of radiographic control

  8. [Occupational stress situation analysis of different types of train drivers].

    Science.gov (United States)

    Zhou, Wenhui; Gu, Guizhen; Wu, Hui; Yu, Shanfa

    2014-11-01

    To analyze the status of occupational stress in different types of train drivers. By using cluster sampling method, a cross-sectional study was conducted in 1 339 train drivers (including 289 passenger train drivers, 637 freight trains drivers, 339 passenger shunting train drivers, and 74 high speed rail drivers) from a Railway Bureau depot. The survey included individual factors, occupational stress factors, stress response factors and stress mitigating factors. The occupational stress factors, stress response factors and mitigating factors were measured by the revised effort-reward imbalance (ERI) model questionnaires and occupational stress measurement scale. By using the method of covariance analysized the difference of occupational stress factors of all types train drivers, the method of Stepwise regression was used to analyze the effection (R(2)) of occupational stress factors and stress mitigating factors on stress response factors. Covariance analysis as covariates in age, education level, length of service and marital status showed that the scores of ERI (1.58 ± 0.05), extrinsic effort (19.88 ± 0.44), rewards (23.43 ± 0.43), intrinsic effort (17.86 ± 0.36), physical environment (5.70 ± 0.22), social support (30.51 ± 0.88) and daily tension (10.27 ± 0.38 ) of high speed rail drivers were higher than other drivers (F values were 6.06, 11.32, 7.05, 13.25, 5.20, 9.48 and 6.14 respectively, P occupational stress factors and mitigating factors to depressive symptoms of train drivers was high speed rail drivers (R(2) = 0.64), passenger train drivers (R(2) = 0.44), passenger shunting train drivers (R(2) = 0.39), freight trains drivers (R(2) = 0.38); job satisfaction of train drivers was high speed rail drivers (R(2) = 0.68), passenger train drivers (R(2) = 0.62), freight trains drivers (R(2) = 0.43), passenger shunting train drivers(R(2) = 0.38); to daily tension of train drivers was high speed rail drivers (R(2) = 0.54), passenger train drivers (R(2) = 0

  9. The radiographic image: A cultural artefact?

    International Nuclear Information System (INIS)

    Strudwick, Ruth M.

    2014-01-01

    This article looks at the role of the radiographic images produced by diagnostic radiographers. An ethnographic study of the workplace culture in one diagnostic imaging department was undertaken using participant observation for four months and semi-structured interviews with ten key informants. One of the key themes; that of the radiographic image as a cultural artefact, is explored in this article. The radiographic image is a cultural artefact which radiographers are protective of and take ownership of. Radiographers are conscious of the quality of their images and the images are an important aspect of their work. Radiographers take criticism of their images personally. The radiographic image is a record of the interaction that occurs between the radiographer and the patient. The way in which radiographic images are viewed, used and judged is an important aspect of the role of diagnostic radiographer

  10. Basal cell naevus syndrome - radiographic findings in the skull

    Energy Technology Data Exchange (ETDEWEB)

    Stoll, P.; Dueker, J.; Weingart, D.

    1986-09-01

    Besides uni- and multiocular jaw cysts the Gorlin Goltz syndrome shows other characteristic radiographic findings which help to ensure diagnosis. These are particularly calcification of the falx cerebri and a so called ''bridging'' between processus clinoideus anterior and posterior of the sella turcica. The importance of early diagnosis is stressed.

  11. The basal cell naevus syndrome - radiographic findings in the skull

    International Nuclear Information System (INIS)

    Stoll, P.; Dueker, J.; Weingart, D.

    1986-01-01

    Besides uni- and multiocular jaw cysts the Gorlin Goltz syndrome shows other characteristic radiographic findings which help to ensure diagnosis. These are particularly calcification of the falx cerebri and a so called ''bridging'' between processus clinoideus anterior and posterior of the sella turcica. The importance of early diagnosis is stressed. (orig.) [de

  12. Radiographic film cassette unloading apparatus

    International Nuclear Information System (INIS)

    Stievenart, E.F.; Plessers, H.S.; Neujens, G.J.

    1980-01-01

    Apparatus for unloading cassettes, containing exposed radiographic films, has means for unfastening the cassettes, an inclined pathway for gravity feeding and rotating feed members (rollers or belts) to propel the films into the processor. (UK)

  13. Stress analysis of fuelling machine magazine housing of PHWR

    International Nuclear Information System (INIS)

    Singh, R.K.; Mehra, V.K.; Charan, J.J.; Kakodkar, A.

    1983-01-01

    PWR has fuelling machines for on-line refuelling of the core. Magazine housing of this fuelling machine is a thick pressure vessel. It has a cylindrical vessel with flat head on one side and reservable flange closure on the other side. The vessel has many small and big openings. This paper describes the two sets of experiments conducted for its stress analysis. First set of experiment was conducted on a 1:5 photoelastic model which was stress frozen under load of internal pressure. The second set of experiment involved strain gauge measurements at some important locations of the magazine housing. The paper summarises results of the experiments. In conclusion comparison is made between the experimental results and the results of finite element analysis. (orig.)

  14. The reliability of tablet computers in depicting maxillofacial radiographic landmarks

    Energy Technology Data Exchange (ETDEWEB)

    Tadinada, Aditya; Mahdian, Mina; Sheth, Sonam; Chandhoke, Taranpreet K.; Gopalakrishna, Aadarsh; Potluri, Anitha; Yadav, Sumit [University of Connecticut School of Dental Medicine, Farmington (United States)

    2015-09-15

    This study was performed to evaluate the reliability of the identification of anatomical landmarks in panoramic and lateral cephalometric radiographs on a standard medical grade picture archiving communication system (PACS) monitor and a tablet computer (iPad 5). A total of 1000 radiographs, including 500 panoramic and 500 lateral cephalometric radiographs, were retrieved from the de-identified dataset of the archive of the Section of Oral and Maxillofacial Radiology of the University Of Connecticut School Of Dental Medicine. Major radiographic anatomical landmarks were independently reviewed by two examiners on both displays. The examiners initially reviewed ten panoramic and ten lateral cephalometric radiographs using each imaging system, in order to verify interoperator agreement in landmark identification. The images were scored on a four-point scale reflecting the diagnostic image quality and exposure level of the images. Statistical analysis showed no significant difference between the two displays regarding the visibility and clarity of the landmarks in either the panoramic or cephalometric radiographs. Tablet computers can reliably show anatomical landmarks in panoramic and lateral cephalometric radiographs.

  15. Relationships between rotator cuff tear types and radiographic abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soo Hyun; Chun, Kyung Ah; Lee Soo Jung; Kang, Min Ho; Yi, Kyung Sik; Zhang, Ying [Dept. of Diagnostic Radiology, College of Medicine, Chungbuk National University, Cheongju (Korea, Republic of)

    2014-11-15

    To determine relationships between different types of rotator cuff tears and radiographic abnormalities. The shoulder radiographs of 104 patients with an arthroscopically proven rotator cuff tear were compared with similar radiographs of 54 age-matched controls with intact cuffs. Two radiologists independently interpreted all radiographs for; cortical thickening with subcortical sclerosis, subcortical cysts, osteophytes in the humeral greater tuberosity, humeral migration, degenerations of the acromioclavicular and glenohumeral joints, and subacromial spurs. Statistical analysis was performed to determine relationships between each type of rotator cuff tears and radiographic abnormalities. Inter-observer agreements with respect to radiographic findings were analyzed. Humeral migration and degenerative change of the greater tuberosity, including sclerosis, subcortical cysts, and osteophytes, were more associated with full-thickness tears (p < 0.01). Subacromial spurs were more common for full-thickness and bursal-sided tears (p < 0.01). No association was found between degeneration of the acromioclavicular or glenohumeral joint and the presence of a cuff tear. Different types of rotator cuff tears are associated with different radiographic abnormalities.

  16. Relationships between rotator cuff tear types and radiographic abnormalities

    International Nuclear Information System (INIS)

    Lee, Soo Hyun; Chun, Kyung Ah; Lee Soo Jung; Kang, Min Ho; Yi, Kyung Sik; Zhang, Ying

    2014-01-01

    To determine relationships between different types of rotator cuff tears and radiographic abnormalities. The shoulder radiographs of 104 patients with an arthroscopically proven rotator cuff tear were compared with similar radiographs of 54 age-matched controls with intact cuffs. Two radiologists independently interpreted all radiographs for; cortical thickening with subcortical sclerosis, subcortical cysts, osteophytes in the humeral greater tuberosity, humeral migration, degenerations of the acromioclavicular and glenohumeral joints, and subacromial spurs. Statistical analysis was performed to determine relationships between each type of rotator cuff tears and radiographic abnormalities. Inter-observer agreements with respect to radiographic findings were analyzed. Humeral migration and degenerative change of the greater tuberosity, including sclerosis, subcortical cysts, and osteophytes, were more associated with full-thickness tears (p < 0.01). Subacromial spurs were more common for full-thickness and bursal-sided tears (p < 0.01). No association was found between degeneration of the acromioclavicular or glenohumeral joint and the presence of a cuff tear. Different types of rotator cuff tears are associated with different radiographic abnormalities.

  17. Thermoelastic stress analysis system developed for industrial applications

    DEFF Research Database (Denmark)

    Haldorsen, Lars Magne

    The thesis is divided into three parts. The first part describes an extensive evaluation of the existing thermoelastic theory. The second part describes the development and results af a reliable numerical simulation code of the thermoelastic effect and the associated heat transfer effects. Finall......, theories, methods and additional equipment are developed in order to adopt a commercial IR-imaging system to preform Termoelastic Stress Analysis (TSA)....

  18. Method for taking X radiographs

    International Nuclear Information System (INIS)

    Orth, G.

    1983-01-01

    The method is aimed at obtaining X radiographs of any human organ with the aid of an X-ray-shadowless radiation detector of a dose measuring device, which is arranged between patient and imaging system, and of a controlling microprocessor system, so that the image-forming parameters are automatically adjusted to the specific properties of the patient. This procedure minimices the efforts in preparing the radiograph and the radiation exposure of the patient

  19. Film holder for radiographing tubing

    International Nuclear Information System (INIS)

    Davis, E.V.; Foster, B.E.

    1976-01-01

    A film cassette is described which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro

  20. The radiographic manifestations of hypochondroplasia

    International Nuclear Information System (INIS)

    Heselson, N.G.; Cremin, B.J.; Beighton, P.

    1979-01-01

    Hypochrondroplasia is an inherited skeletal dysplasia that resembles achondroplasia in mild degree. Radiographic manifestations encountered in 12 affected individuals in South Africa include slight shortening of all segments of the tubular bones, moderate caudal diminution of the lumbar interpedicular distances, increased lumbar lordosis with cacral tilt and distal prolongation of the fibular. Hypochondroplasia can be distinguished from other osteochondrodystrophies such as achondroplasia, pseudo-achondroplasia and metaphyseal chondroplasia by the recognition of it clinical and radiographic manifestations. (author)

  1. Film holder for radiographing tubing

    Science.gov (United States)

    Davis, Earl V.; Foster, Billy E.

    1976-01-01

    A film cassette is provided which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro.

  2. Radionuclide Imaging of Musculoskeletal Injuries in Athletes with Negative Radiographs.

    Science.gov (United States)

    Nagle, C E; Freitas, J E

    1987-06-01

    In brief: Radionuclide bone scans can be useful in the diagnostic evaluation of musculoskeletal injuries in athletes. Bone scans can detect shinsplints, stress fractures, and muscle injuries before they are detectable on radiographs. Prognosis can be accurately assessed, allowing appropriate treatment to proceed without delay. The authors discuss the use of bone scans and identify musculoskeletal injuries that are associated with specific sports, such as stress fracture of the femur (soccer), tibia (running), scapula (gymnastics), and pars interarticularis (football or lacrosse).

  3. Analysis of the Citrullus colocynthis transcriptome during water deficit stress.

    Directory of Open Access Journals (Sweden)

    Zhuoyu Wang

    Full Text Available Citrullus colocynthis is a very drought tolerant species, closely related to watermelon (C. lanatus var. lanatus, an economically important cucurbit crop. Drought is a threat to plant growth and development, and the discovery of drought inducible genes with various functions is of great importance. We used high throughput mRNA Illumina sequencing technology and bioinformatic strategies to analyze the C. colocynthis leaf transcriptome under drought treatment. Leaf samples at four different time points (0, 24, 36, or 48 hours of withholding water were used for RNA extraction and Illumina sequencing. qRT-PCR of several drought responsive genes was performed to confirm the accuracy of RNA sequencing. Leaf transcriptome analysis provided the first glimpse of the drought responsive transcriptome of this unique cucurbit species. A total of 5038 full-length cDNAs were detected, with 2545 genes showing significant changes during drought stress. Principle component analysis indicated that drought was the major contributing factor regulating transcriptome changes. Up regulation of many transcription factors, stress signaling factors, detoxification genes, and genes involved in phytohormone signaling and citrulline metabolism occurred under the water deficit conditions. The C. colocynthis transcriptome data highlight the activation of a large set of drought related genes in this species, thus providing a valuable resource for future functional analysis of candidate genes in defense of drought stress.

  4. Structural and stress analysis of nuclear piping systems

    International Nuclear Information System (INIS)

    Hata, Hiromichi

    1982-01-01

    The design of the strength of piping system is important in plant design, and its outline on the example of PWRs is reported. The standards and guides concerning the design of the strength of piping system are shown. The design condition for the strength of piping system is determined by considering the requirements in the normal operation of plants and for the safety design of plants, and the loads in normal operation, testing, credible accident and natural environment are explained. The methods of analysis for piping system are related to the transient phenomena of fluid, piping structure and local heat conduction, and linear static analysis, linear time response analysis, nonlinear time response analysis, thermal stress analysis and fluid transient phenomenon analysis are carried out. In the aseismatic design of piping system, it is desirable to avoid the vibration together with a building supporting it, and as a rule, to make it into rigid structure. The piping system is classified into high temperature and low temperature pipings. The formulas for calculating stress and the allowable condition, the points to which attention must be paid in the design of piping strength and the matters to be investigated hereafter are described. (Kako, I.)

  5. Radiographic bone loss in a Scottish non-smoking Type 1 Diabetes mellitus population; a Bitewing Radiographic Study.

    Science.gov (United States)

    Plessas, Anastasios; Robertson, Douglas P; Hodge, Penny J

    2018-05-15

    The dental complications of uncontrolled diabetes include reduced salivary flow rate, candidiasis and periodontal manifestations. A recent meta-analysis concluded that diabetes patients have a significantly higher severity, but not extent, of destructive periodontal disease than non-diabetes people. The authors reported that most type-1 diabetes studies using dental radiographic data have not controlled for confounding factors such as smoking. The aim of this cross-sectional study was to compare radiographic alveolar bone loss between type 1 diabetes (T1DM) and non-diabetes (NDM) participants in a Scottish non-smoking population. Digital bitewing radiographs for 174 Scottish adult never or ex-smoker (> 5 years) participants (108 T1DM, 66 NDS), recruited from outpatient clinics throughout Greater Glasgow and Clyde, were included in the analysis. A single blinded, trained and calibrated examiner recorded the radiographic bone loss seen on bitewing radiographs using the digital screen caliper. The bone loss was measured as the distance between the cemento-enamel junction (CEJ) and the deepest radiographic alveolar bone margin interproximally of each tooth. T1DM participants had more radiographic alveolar bone loss throughout the all teeth measured (median:1.27 mm vs 1.06 mm, P diabetes subjects. Patients suffering from type 1 diabetes are at higher risk of periodontitis even when controlling for multiple possible confounding factors and this difference can be detected on routine dental radiographs at an early stage. These data confirm radiographically the previously reported association between T1DM and periodontal bone loss. This article is protected by copyright. All rights reserved. © 2018 American Academy of Periodontology.

  6. Digital radiographic assessment of coronary flow reserve

    International Nuclear Information System (INIS)

    Vogel, R.A.

    1985-01-01

    A method for measuring relative changes in regional blood flow using digital radiographic enhancement of selective coronary arteriography. Coronary flow reserve is measured in individual arterial distributions using the washin ratio of contrast appearance time under baseline and hyperemic conditions. Information is quantitatively presented in functional (parametric) image format. These images, termed contrast medium appearance pictures (CMAP), depict the transit of contrast through the arterial, myocardial and early venous stages. This process can be divided into three general phases: data acquisition, CMAP formation and CMAP analysis. The technique has evolved over its development period from a cine film-based technology which required substantial processing time to a real-time digital radiographic technique

  7. Radiographical measurements for distal intra-articular fractures of the radius using plain radiographs and cone beam computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Suojaervi, Nora; Lindfors, N. [Helsinki University Central Hospital, Department of Hand Surgery, Helsinki (Finland); Sillat, T.; Koskinen, S.K. [HUS Helsinki Medical Imaging Center, Helsinki University Central Hospital, Department of Radiology, Helsinki (Finland)

    2015-12-15

    Operative treatment of an intra-articular distal radius fracture is one of the most common procedures in orthopedic and hand surgery. The intra- and interobserver agreement of common radiographical measurements of these fractures using cone beam computed tomography (CBCT) and plain radiographs were evaluated. Thirty-seven patients undergoing open reduction and volar fixation for a distal radius fracture were studied. Two radiologists analyzed the preoperative radiographs and CBCT images. Agreement of the measurements was subjected to intra-class correlation coefficient and the Bland-Altman analyses. Plain radiographs provided a slightly poorer level of agreement. For fracture diastasis, excellent intraobserver agreement was achieved for radiographs and good or excellent agreement for CBCT, compared to poor interobserver agreement (ICC 0.334) for radiographs and good interobserver agreement (ICC 0.621) for CBCT images. The Bland-Altman analyses indicated a small mean difference between the measurements but rather large variation using both imaging methods, especially in angular measurements. For most of the measurements, radiographs do well, and may be used in clinical practice. Two different measurements by the same reader or by two different readers can lead to different decisions, and therefore a standardization of the measurements is imperative. More detailed analysis of articular surface needs cross-sectional imaging modalities. (orig.)

  8. Radiographical measurements for distal intra-articular fractures of the radius using plain radiographs and cone beam computed tomography images.

    Science.gov (United States)

    Suojärvi, Nora; Sillat, T; Lindfors, N; Koskinen, S K

    2015-12-01

    Operative treatment of an intra-articular distal radius fracture is one of the most common procedures in orthopedic and hand surgery. The intra- and interobserver agreement of common radiographical measurements of these fractures using cone beam computed tomography (CBCT) and plain radiographs were evaluated. Thirty-seven patients undergoing open reduction and volar fixation for a distal radius fracture were studied. Two radiologists analyzed the preoperative radiographs and CBCT images. Agreement of the measurements was subjected to intra-class correlation coefficient and the Bland-Altman analyses. Plain radiographs provided a slightly poorer level of agreement. For fracture diastasis, excellent intraobserver agreement was achieved for radiographs and good or excellent agreement for CBCT, compared to poor interobserver agreement (ICC 0.334) for radiographs and good interobserver agreement (ICC 0.621) for CBCT images. The Bland-Altman analyses indicated a small mean difference between the measurements but rather large variation using both imaging methods, especially in angular measurements. For most of the measurements, radiographs do well, and may be used in clinical practice. Two different measurements by the same reader or by two different readers can lead to different decisions, and therefore a standardization of the measurements is imperative. More detailed analysis of articular surface needs cross-sectional imaging modalities.

  9. Structural Stress Analysis of an Engine Cylinder Head

    Directory of Open Access Journals (Sweden)

    R. Tichánek

    2005-01-01

    Full Text Available This paper deals with a structural stress analysis of the cylinder head assembly of the C/28 series engine. A detailed FE model was created for this purpose. The FE model consists of the main parts of the cylinder head assembly, and it includes a description of the thermal and mechanical loads and the contact interaction between their parts. The model considers the temperature dependency of the heat transfer coefficient on wall temperature in cooling passages. The paper presents a comparison of computed and measured temperature. The analysis was carried out using the FE program ABAQUS. 

  10. Residual stress analysis on materials with steep stress gradient by using X-ray incidence at higher angles

    International Nuclear Information System (INIS)

    Ohya, Shin-ichi; Yoshioka, Yasuo; Maeno, Shigeki

    1996-01-01

    X-ray stress measurements for isotropic polycrystalline are materials are usually carried out by the sin 2 ψ method under the assumption of no stress gradient in X-ray penetration depth. When a steep stress gradient exists in the vicinity of surface layer, however, non-linear sin 2 ψ relation is observed and the sin 2 ψ method cannot be applied on such cases. Although several X-ray stress analyzers have been developed for materials with steep stress gradient in the surface layer, it is desirable to use diffraction data at higher incident angles of ψ 0 as possible as close on 90 degrees in order to determine the both values of surface stress and stress gradient with high accuracy. In the present study, an X-ray stress analyzer based on Ω geometry was fabricated to enable X-ray incidence at higher angle of ψ 0 . The X-ray detector was positioned on -η side against X-ray incident beam. Both of the residual surface stress and stress gradient were determined by use of the COSψ method on shot-peened steel and silicon nitride specimens. This prototype stress analyzer was found effective to perform a biaxial or triaxial stress analysis. (author)

  11. Radiographic alterations of the frontal sinus morphology according to variations of the vertical angle in posteroanterior radiographs of the skull

    Directory of Open Access Journals (Sweden)

    Rhonan Ferreira Silva

    2014-03-01

    The frontal sinuses play a highly relevant role in comparative human identification processes. Since forensic radiology is a branch in the forensic sciences, adequate radiological analysis of the frontal sinuses is essential for comparative human identifications. The current study investigates radiographic morphological changes in the frontal sinuses according to vertical angle distortions in posteroanterior (PA radiographs. A standard PA radiograph of the skull of an adult was obtained. Eight addition PA radiographs were taken at different vertical angles. Frontal sinuses were analyzed qualitatively and quantitatively according to Ribeiro´s (2000 technique. Both qualitative and quantitative analyses revealed significant image distortions. Further, overlapping anatomical structures were reported when PA radiographs were analyzed in negative angulation distortions (from -10° to -40°. Positive and negative angular distortions up to 20º slightly affected the qualitative morphological analysis. However, 10° positive and negative distortions provided a significant interference in quantitative analysis and impaired the measuring process. Most forensic techniques for the analysis of frontal sinuses comprise measurements of morphological distances. Distortions of approximately 10° or over in vertical angulation of cranial PA radiographs should be avoided so that more accurate comparative human identifications could be achieved.

  12. Factors Associated with the Use of Hyaluronic Acid and Corticosteroid Injections among Patients with Radiographically Confirmed Knee Osteoarthritis: A Retrospective Data Analysis.

    Science.gov (United States)

    Lapane, Kate L; Liu, Shao-Hsien; Dubé, Catherine E; Driban, Jeffrey B; McAlindon, Timothy E; Eaton, Charles B

    2017-02-01

    Despite the rapid proliferation of hyaluronate (HA) and corticosteroid (CO) injections and clinical guidelines regarding their use in osteoarthritis (OA), information on the characteristics of people receiving these injections is scarce. We describe the use of injections among adults with radiographically confirmed knee OA and identify factors associated with injection use. We used publicly available data from the Osteoarthritis Initiative (OAI), an international collaboration sponsored by the National Institutes of Health, and included participants with ≥1 radiographically confirmed knee OA (Kellgren-Lawrence grade ≥2 [definite osteophytes and possible joint space narrowing (JSN) on anteroposterior weight-bearing radiograph]) at baseline. We matched 415 participants who received at least 1 HA and/or CO injection during the 6-month interval before 1 of the first 7 annual follow-up assessments to 1841 injection nonusers by randomly selecting a study visit to match the distribution observed in the injection users. Multinomial logistic regression models were used for identifying factors associated with injection use, including sociodemographic and clinical/functional factors. Eighteen percent of the 2256 patients identified as having knee OA had received at least 1 injection (years 1-7, 16.9%, 13.7%, 16.6%, 13.5%, 15.9%, 13.5%, and 9.9%, respectively), most commonly with CO (68.4%). HA and CO were more commonly injected in those with a higher annual household income (adjusted odds ratio [aOR] [95% CI] with HA, US ≥$50,000 vs injection may be associated with higher socioeconomic positioning and indicators of greater disease severity in patients with knee OA. Copyright © 2017. Published by Elsevier Inc.

  13. Radiographic detection of IGSCC

    International Nuclear Information System (INIS)

    Schonberg, R.G.

    1985-01-01

    One of the most troubling problems which the nuclear industry faces is intergranular stress corrosion cracking on BWR reactors. The development of the MINAC, a highly portable high energy X-ray source, makes field radiography possible on thick section of primary piping. Radiography through total steel thicknesses of up to 300 mm has been done with a 45 minute exposure with a F.F.D. of 1.6 meters

  14. Radiographic cephalometric study using Ricketts analysis for dentoskeletal patterns evaluation of patients having class II, division I malocclusion treated during mixed dentition period

    International Nuclear Information System (INIS)

    Motta e Albuquerque, Carmen da.

    1988-01-01

    In the specialized literature about the use of extra oral forces in the treatment of the Class II malocclusion one can observe that it has been used more and more, with the objective of achieving teeth improvement and bone as well. It is proposed to evaluate the extent of the orthodontic/orthopedic modifications and their influence in the facial pattern of patients with those malocclusions, treated during the mixed dentition period. A sample of 32 patients of both sexes, leucoderms, with Class II, division I malocclusion, between 7 and 14 years old, were studied employing a cephalometric radiographic method for evaluation. (author). 94 refs., 11 figs., 15 tabs

  15. Preliminary analysis of doses to evaluate the image quality in radiographic examinations in veterinary radiology;Analise preliminar das doses para avaliacao da qualidade da imagem em exames radiograficos na radiologia veterinaria

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Ana Carolina B.C.F.; Dias, Mayara T.P.; Santos, Andrea C. [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia; Melo, Camila S.; Furquim, Tania A.C. [Universidade de Sao Paulo (IEE/USP), SP (Brazil). Inst. de Eletrotecnica e Energia

    2009-07-01

    This work has as objective to promote the analysis of the radiological doses and quality of the image of the technical letter used for the accomplishment of thorax and coxal radiographic examination of animals of canine and feline species. The study was accomplished in the service of Diagnosis for Image in Veterinarian Hospital of Veterinary Medicine and Zootecnia College of University of Sao Paulo, in two conventional equipment. Initially, physical features of the animals and the technique used were collected for each one of the 188 radiographic examinations of thorax and 52 examinations of coxal. The animals were placed in different groups, according to their body weight. For each group, the averages for each feature were calculated: thickness of the radiographed region, tension, electric current, time of exhibition, current product electric-time, size of the used film, presence or absence of bucky and feature of focus (narrow or thick). On the basis of the averages of group M (of lesser weights that 5kg for cats and between 10,1kg and 20kg for dogs), was executed a physical analysis of the current technical letter, using the equipment: ionization chamber (to determinate the value of kerma in air), simulator objects (representative of the thickness of the animal) and three dispositive standards of test that evaluate space resolution, resolution in low contrast and contrast-detail. The obtained images were analyzed and compared for a physicist and a radiologist medical veterinary. The results had shown that the examinations supply dose considered high for techniques used mainly for coxal. The equipment A, although to supply higher doses, presents the better images for the majority of the projections. However, the study indicates that there are not exactly reference levels, but these examinations must pass for improvement of quality of image (author)

  16. Three dimensional, thermal stress analysis of a welded plate

    International Nuclear Information System (INIS)

    Koening, H.A.; Lai, C.K.-F.; Morral, J.E.

    1985-01-01

    A general finite element thermal stress analysis has been developed. The analysis can be uncoupled to solve either the heat transfer problem or the stress problem independently and it can accommodate non-linear material behavior, initial states of stress and strain, and moving boundary conditions. A unique feature of the model it that it properly accounts for the latent heat effect during phase changes. Applying the moving heat flux boundary condition to simulate arc welding, the model has been used to predict the transient thermal mechanical response of a welded plate. It is the absorption and liberation of latent heat in the fusion zone of a weld which complicates numerical methods of treating welding. For pure materials and eutectic alloys the latent heat effect is less of a problem because phase changes take place at a specific temperature. But for most alloys, phase changes take place over a range of temperatures bounded by the solidus, T S , and liquidus, T L , and the latent heat effect occurs continuously over the temperature range. (author)

  17. The stress analysis and stress evaluates of γ-spectrometer-probe station

    International Nuclear Information System (INIS)

    Li Hailong

    2005-01-01

    γ-Spectrometer -Probe Station is used for monitoring the reactor core fuel assemblies. The structural framework of this equipment possessed the massive lead bricks and linear supports. The article uses the finite element method and the conversion density method for processing lead bricks. Using shell element makes the analysis of liberating shape. The rigid supports are proposed and the stacking of the lead-bricks is improved. Meanwhile, the optimized design has been conducted for the equipment component. Using the computed results, the stress evaluate of the equipment is strictly made according to the ASME codes and standards. (author)

  18. Radiographic examination of the equine head

    International Nuclear Information System (INIS)

    Park, R.D.

    1993-01-01

    Radiographic examinations of the equine head can be performed with portable x-ray machines. The views comprising the examination depend on the area of the head being examined. With a knowledge of radiographic anatomy and radiographic signs of disease, valuable diagnostic information can be obtained from the radiographic examination. In addition, the radiographic information can also be used to develop a prognosis and determine the most appropriate therapy

  19. Radiographic testing at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Bossi, R.H.

    1982-01-01

    Radiographic testing is a nondestructive inspection technique which uses penetrating radiation. The Nondestructive Evaluation (NDE) Section at Lawrence Livermore National Laboratory has a broad spectrum of equipment and techniques for radiographic testing. These resources include low-energy vacuum systems, low- and mid-energy cabinet and cell radiographic systems, high-energy linear accelerators, portable x-ray machines and radioisotopes for radiographic inspections. For diagnostic testing the NDE Section also has real-time and flash radiographic equipment

  20. contact stress analysis of involute spur gear by finite element method

    African Journals Online (AJOL)

    USER

    section using C- programming. Bending stress analysis has been performed using finite element analysis with ANSYS software. Comparison of bending stress analysis has been performed for symmetric and asymmetric spur gear tooth at critical section. Mushin J. Jweeg, et.al. [7] used 2D contact stress FEA model to ...

  1. Reproductive health of male radiographers

    International Nuclear Information System (INIS)

    Shakhatreh, Farouk M.

    2001-01-01

    To compare certain reproductive health problems reported in 2 groups of males, one of which was exposed to x-ray radiation (radiographers) and the other group that was not exposed to x-ray radiation. The reproductive health problems were miscarriage, congenital anomalies, still births and infertility. Two groups of men were selected (90 in each group). The first group consisted of radiographers and the other groups consisted of men not exposed to x-ray radiation. The 2 groups were matched for age and source. Relative risk, attributable risk percentage and level of significance were calculated. Incidence rate of reproductive health problems was increasing with the increase in duration of exposure to x-ray radiation ranging between 17% (for those exposed for 1-5 years) to 91% (for those exposed for more than 15 years). There were significant associations between exposure to radiation and miscarriage (relative risk = 1.67, attributable risk percentage = 40%), congenital anomalies (relative risk = 10, attributable risk percentage 90%), still birth (relative risk = 7, attributable risk percentage = 86%), and infertility (relative risk = 4.5, attributable risk = 78%). The incidence rates of reproductive health problems reported by male radiographers were significantly higher than that reported by the non exposed group and higher than the incidence rates reported in community-based studies in Jordan. The incidence rates of fetal death (miscarriage and stillbirth together) and infertility reported by our radiographers were higher than had been reported by the British radiographers. An immediate plan of action is needed to protect our radiographers. Further studies are needed in this field taking into account all extraneous variables that may affect the reproductive health of radiographers. (author)

  2. X-ray multiaxial stress analysis by means of polynomial approximation and an application to plane stress problem

    International Nuclear Information System (INIS)

    Yoshioka, Yasuo; Sasaki, Toshihiko; Kuramoto, Makoto.

    1984-01-01

    A new polynomial approximation method was proposed for the X-ray multiaxial stress analysis, in which the effect of stress gradient along the penetration depth of X-rays was taken into account. Three basic assumptions were made; (1) the stress gradient is linear in respect to the depth from the specimen surface, (2) the ponetration depth of X-rays is a function of Sin 2 phi and (3) the strain measured by X-rays corresponds to the weighted average strain on the intensity of the diffracted X-rays. Consequently, the stress state within the thin layer near the surface was expressed by making use of three surface stresses and six stress gradients in the present method. The average strains by X-rays were approximated by the third order polynomial equations of sin 2 phi using a least square method at several phi angles on the coordinate system of specimen. Since the coefficients of these polynomials include these nine stress components mentioned above, it is possible to solve them as simultaneous equations. The calculating process of this method is simpler than that of the integral method. An X-ray plane stress problem was analyzed as an application of the present method, and the residual stress distribution on a shot-peened steel plate was actually measured by use of Cr-Kα X-rays to verify the analysis. The result showed that the compressive residual stress near the surface determined by the present method was smaller than the weighted average stress by the Sin 2 phi method because of the steep stress gradient. The present method is useful to obtain a reasonable value of stress for such a specimen with steep stress gradients near the surface. (author)

  3. Numerical analysis of stress fields generated by quenching process

    Directory of Open Access Journals (Sweden)

    A. Bokota

    2011-04-01

    Full Text Available In work the presented numerical models of tool steel hardening processes take into account mechanical phenomena generated by thermalphenomena and phase transformations. In the model of mechanical phenomena, apart from thermal, plastic and structural strain, alsotransformations plasticity was taken into account. The stress and strain fields are obtained using the solution of the Finite Elements Method of the equilibrium equation in rate form. The thermophysical constants occurring in constitutive relation depend on temperature and phase composite. For determination of plastic strain the Huber-Misses condition with isotropic strengthening was applied whereas fordetermination of transformation plasticity a modified Leblond model was used. In order to evaluate the quality and usefulness of thepresented models a numerical analysis of stresses and strains associated hardening process of a fang lathe of cone shaped made of tool steel was carried out.

  4. Stochastic thermal stress analysis of clad cylindrical fuel elements

    International Nuclear Information System (INIS)

    Barrett, P.R.

    1975-01-01

    After a review of deterministic elastic thermal stress analysis by means of the displacement method for a cylindrical system in which the temperature distribution is not only radially variable but azimuthally and axially variable also, a method is shown for the determination of the statistical moments of the stress components when (a) the outer boundary of the cladding is a stochastic quantity, and (b) the uncertainties in the elastic and thermal constants of the materials and in the magnitude of the heat generation term are taken into account. A typical model is proposed for describing the statistics of the outer radius of the cladding which is a stochastic variable owing to uncertainties produced by the extrusion process. The theory is illustrated by means of a simple example by examining a meaningful reliability index and the relative importance of each of the uncertainties. (Auth.)

  5. Stress analysis studies in optimised 'D' shaped TOKAMAK magnet designs

    International Nuclear Information System (INIS)

    Diserens, N.J.

    1975-07-01

    A suite of computer programs TOK was developed which enabled simple data input to be used for computation of magnetic fields and forces in a toroidal system of coils with either D-shaped or circular cross section. An additional requirement was that input data to the Swansea stress analysis program FINESSE could be output from the TOK fields and forces program, and that graphical output from either program should be available. A further program was required to optimise the coil shape. This used the field calculating routines from the TOK program. The starting point for these studies was the proposed 40 coil Princeton design. The stresses resulting from three different shapes of D-coil were compared. (author)

  6. Macro design effects on stress distribution around implants: A photoelastic stress analysis

    Directory of Open Access Journals (Sweden)

    Serhat Emre Ozkir

    2012-01-01

    Conclusion: As there were observable differences between the implant types, straight placed cylindrical implants showed better stress distribution characteristics, while inclined tapering implants had better stress distribution characteristics.

  7. Evaluation of Radiographic Instability of the Trapeziometacarpal Joint in Women With Carpal Tunnel Syndrome.

    Science.gov (United States)

    Kim, Jeong Hwan; Gong, Hyun Sik; Kim, Youn Ho; Rhee, Seung Hwan; Kim, Jihyoung; Baek, Goo Hyun

    2015-07-01

    To determine whether median nerve dysfunction measured by electrophysiologic studies in carpal tunnel syndrome (CTS) is associated with thumb trapeziometacarpal (TMC) joint instability. We evaluated 71 women with CTS and 31 asymptomatic control women. Patients with generalized laxity or TMC joint osteoarthritis were excluded. We classified the electrophysiologic severity of CTS based on nerve conduction time and amplitude and assessed radiographic instability of the TMC joint based on TMC joint stress radiographs. We compared subluxation ratio between patients with CTS and controls and performed correlation analysis of the relationship between the electrophysiologic grade and subluxation ratio. Thirty-one patients were categorized into the mild CTS subgroup and 41 into the severe CTS subgroup. There was no significant difference in subluxation ratio between the control group and CTS patients or between the control group and CTS subgroup patients. Furthermore, there was no significant correlation between electrophysiologic grade and subluxation ratio. This study demonstrated that patients with CTS did not have greater radiographic TMC joint instability compared with controls, and suggests that TMC joint stability is not affected by impaired median nerve function. Further studies could investigate how to better evaluate proprioceptive function of TMC joint and whether other nerves have effects on TMC joint motor/proprioceptive function, to elucidate the relationship between neuromuscular control of the TMC joint, its stability, and its progression to osteoarthritis. Diagnostic II. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  8. A radiographic study of mental foramen in intraoral radiographs

    International Nuclear Information System (INIS)

    Sohn, Jeong Ick; Choi, Karp Shik

    1995-01-01

    The purpose of this study was to evaluate the position and shape of mental foramen in periapical radiographs. For this study, periapical radiographs of premolar areas were obtained from the 200 adults. Accordingly, the positional and shape changes of mental foramen were evaluated. The authors obtained radiographs according to changes in radiation beam direction in periapical radiographs of premolar areas, and then evaluated the positional and shape changes of mental foramen. The following results were obtained: 1. Shapes of mental foramen were observed elliptical (34.3%), round or oval (28.0%), unidentified (25.5%) and diffuse (12.2%) type in descending order of frequency. 2, Horizontal positions of mental foramen were most frequently observed at the 2nd premolar area (55.3%), the area between the 1st premolar and 2nd premolar (39.6%), the area between the 2nd premolar and 1st molar (3.4%), the 1st premolar area (1.0%), the area between the canine and 1st premolar (0.7%) in descending order of frequency. 3. Vertical positions of mental foramen were most frequently observed at the inferior to apex (67.1%), and at apex (24.8%), overlap with apex (6.4%), superior to apex (1.7%) in descending order of frequency. 4. Shapes of mental foramen were more obviously observed at the upward 10 degree positioned periapical radiographs. And according to the changes of horizontal and vertical position, they were observed similar to normally positioned periapical radiographs.

  9. Attitudes of radiographers to radiographer-led discharge: A survey

    International Nuclear Information System (INIS)

    Lumsden, Laura; Cosson, Philip

    2015-01-01

    Background: The traditional role of the Diagnostic Radiographer in image acquisition has gradually been extended through skill-mix, particularly to include abnormality detection. Aims: This research focused on the attitudes of Radiographers to Radiographer-led Discharge (RLD), where Radiographers discharge patients with minor injuries and perform tasks previously undertaken by Accident and Emergency staff. The effects of job role, hospital type, experience and whether RLD was used in the participant's trust were examined. Method: A multiple-indicator online questionnaire assessed attitudes to RLD. Snowball sampling was used with advertisement via emails, posters and cards, containing Quick Response (QR) codes. Statement responses were coded, with reverse coding for negative statements and total scores were calculated. A higher score represented a more positive attitude. Results: 101 questionnaires were completed (an estimated 30% response rate) and the mean total score was 84/115. 95% of participants supported radiographer involvement in abnormality detection, with 46.5% selecting RLD as the preferred system for minor injuries patients vs 48.5% preferring commenting alone. Discussion: Participants were positive about extending their role through RLD and felt confident in their image interpretation abilities, though expressed concern for the legal consequences of the role and adequate pay. Generalization of the results is limited due to the possible low response rate. Conclusion: Overall, participants demonstrated positive attitudes towards RLD but they also indicate the need for appropriate payment for any additional responsibility. These findings are promising for successful implementation of RLD, though larger-scale research including radiologists, business managers, A and E staff and patients would be beneficial. - Highlights: • 101 questionnaires were completed (an estimated 30% response rate). • 95% of participants supported radiographer involvement

  10. Chest radiographic manifestations of scrub typhus.

    Science.gov (United States)

    Abhilash, Kpp; Mannam, P R; Rajendran, K; John, R A; Ramasami, P

    2016-01-01

    Respiratory system involvement in scrub typhus is seen in 20-72% of patients. In endemic areas, good understanding and familiarity with the various radiologic findings of scrub typhus are essential in identifying pulmonary complications. Patients admitted to a tertiary care center with scrub typhus between October 2012 and September 2013 and had a chest X ray done were included in the analysis. Details and radiographic findings were noted and factors associated with abnormal X-rays were analyzed. The study cohort contained 398 patients. Common presenting complaints included fever (100%), generalized myalgia (83%), headache (65%), dyspnea (54%), cough (24.3%), and altered sensorium (14%). Almost half of the patients (49.4%) had normal chest radiographs. Common radiological pulmonary abnormalities included pleural effusion (14.6%), acute respiratory distress syndrome (14%), airspace opacity (10.5%), reticulonodular opacities (10.3%), peribronchial thickening (5.8%), and pulmonary edema (2%). Cardiomegaly was noted in 3.5% of patients. Breathlessness, presence of an eschar, platelet counts of 2 mg/dL had the highest odds of having an abnormal chest radiograph. Patients with an abnormal chest X-ray had a higher requirement of noninvasive ventilation (odds ratio [OR]: 13.98; 95% confidence interval CI: 5.89-33.16), invasive ventilation (OR: 18.07; 95% CI: 6.42-50.88), inotropes (OR: 8.76; 95% CI: 4.35-17.62), higher involvement of other organ systems, longer duration of hospital stay (3.18 ± 3 vs. 7.27 ± 5.58 days; Pscrub typhus have abnormal chest radiographs. Chest radiography should be included as part of basic evaluation at presentation in patients with scrub typhus, especially in those with breathlessness, eschar, jaundice, and severe thrombocytopenia.

  11. Cauda equina syndrome in the dog: radiographic evaluation

    International Nuclear Information System (INIS)

    Morgan, J.P.; Bailey, C.S.

    1990-01-01

    Dogs with clinical signs typical of cauda equina syndrome require careful evaluation to determine the cause of the disease as this strongly influences choice of treatment. Possible aetiologies include congenital or developmental, inflammatory, traumatic, neoplastic, and degenerative lesions that may involve vertebrae, vertebral joints, intervertebral discs, spinal cord, spinal nerves, or meninges. It must be determined whether clinical signs are due to musculoskeletal or neurological disease before performing special radiographic procedures. Non-contrast radiography permits false-positive diagnosis of obvious degenerative changes involving the L-S disc that may be without clinical signs or permits a false-negative diagnosis due to the failure to appreciate soft tissue lesions not seen radiographically. Special radiographic techniques are recommended and include: (1) stress radiography, (2) discography, and (3) epidural myelography. Evaluation of the results of these studies assists in determining the cause of the cauda equina syndrome and the type of therapy required

  12. Does measurement of the anatomic axis consistently predict hip-knee-ankle angle (HKA) for knee alignment studies in osteoarthritis? Analysis of long limb radiographs from the multicenter osteoarthritis (MOST) study.

    Science.gov (United States)

    Sheehy, L; Felson, D; Zhang, Y; Niu, J; Lam, Y-M; Segal, N; Lynch, J; Cooke, T D V

    2011-01-01

    Researchers commonly use the femoral shaft-tibial shaft angle (FS-TS) from knee radiographs to estimate the hip-knee-ankle angle (HKA) in studies examining risk factors for knee osteoarthritis (OA) incidence and progression. The objective of this study was to determine the relationship between HKA and FS-TS, depending on the method of calculating FS-TS and the direction and degree of knee deformity. 120 full-length digital radiographs were assigned, with 30 in each of four alignment groups (0.0°-4.9°, and ≥5.0° of varus and valgus), from a large cohort of persons with and at risk of knee OA. HKA and five measures of FS-TS (using progressively shorter shaft lengths) were obtained using Horizons Analysis Software, Orthopaedic Alignment & Imaging Systems Inc. (OAISYS). The offsets between HKA and the different versions of FS-TS were calculated, with 95% confidence intervals (CIs). Pearson correlations were calculated. In varus limbs use of a shorter shaft length increased the offset between HKA and FS-TS from 5.1° to 7.0°. The opposite occurred with valgus limbs (from 5.0° to 3.7°). Correlations between HKA and FS-TS for the whole sample of 120 individuals were excellent (r range 1.00-0.88). However, correlations for individual alignment groups were low to moderate, especially for the shortest-shaft FS-TS (r range 0.41-0.66). The offsets obtained using the shorter FS-TS measurements vary depending on direction and degree of knee deformity, and therefore may not provide reliable predictions for HKA We recommend that full-length radiographs be used whenever an accurate estimation of HKA is required, although broad categories of alignment can be estimated with FS-TS. Copyright © 2010 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  13. Stress Analysis of Fuel Rod under Axial Coolant Flow

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Hai Lan; Lee, Young Shin; Lee, Hyun Seung [Chungnam National University, Daejeon (Korea, Republic of); Park, Num Kyu; Jeon, Kyung Rok [Kerea Nuclear Fuel., Daejeon (Korea, Republic of)

    2010-05-15

    A pressurized water reactor(PWR) fuel assembly, is a typical bundle structure, which uses light water as a coolant in most commercial nuclear power plants. Fuel rods that have a very slender and long clad are supported by fuel assembly which consists of several spacer grids. A coolant is a fluid which flows through device to prevent its overheating, transferring the heat produced by the device to other devices that use or dissipate it. But at the same time, the coolant flow will bring out the fluid induced vibration(FIV) of fuel rods and even damaged the fuel rod. This study has been conducted to investigate the flow characteristics and nuclear reactor fuel rod stress under effect of coolant. Fluid structure interaction(FSI) analysis on nuclear reactor fuel rod was performed. Fluid analysis of the coolant which flow along the axial direction and structural analysis under effect of flow velocity were carried out under different output flow velocity conditions

  14. Estructuras de elevadores de carga. // Dumbwaiter structure stress analysis.

    Directory of Open Access Journals (Sweden)

    G. Escobar Travieso

    2006-09-01

    Full Text Available Este trabajo tiene como objetivo analizar las tensiones y deformaciones que ocurren en las estructuras del marco de carro,plataforma y cabina de elevadores de carga mediante la aplicación del Método de los Elementos Finitos, específicamentedel montaplatos de 300 Kg. de capacidad, con vista a realizar el análisis de resistencia, racionalización del peso y material ylas posibles vías de solución.Palabras claves: Elevador de carga, estructuras, análisis de tensiones, elementos finitos.________________________________________________________________________________AbstractThis paper deals with the tension and deformation analysis in structures of lifter mark, platform and cabin offreight lifters by means of the Finite Elements Method, specifically the 300 kgs capacity dumbwaiter, in orderto carry out the resistance analysis, weight and material rationalization.Key words: Dumbwaiter, structures, stress analysis, finite elements.

  15. Stress Analysis of Fuel Rod under Axial Coolant Flow

    International Nuclear Information System (INIS)

    Jin, Hai Lan; Lee, Young Shin; Lee, Hyun Seung; Park, Num Kyu; Jeon, Kyung Rok

    2010-01-01

    A pressurized water reactor(PWR) fuel assembly, is a typical bundle structure, which uses light water as a coolant in most commercial nuclear power plants. Fuel rods that have a very slender and long clad are supported by fuel assembly which consists of several spacer grids. A coolant is a fluid which flows through device to prevent its overheating, transferring the heat produced by the device to other devices that use or dissipate it. But at the same time, the coolant flow will bring out the fluid induced vibration(FIV) of fuel rods and even damaged the fuel rod. This study has been conducted to investigate the flow characteristics and nuclear reactor fuel rod stress under effect of coolant. Fluid structure interaction(FSI) analysis on nuclear reactor fuel rod was performed. Fluid analysis of the coolant which flow along the axial direction and structural analysis under effect of flow velocity were carried out under different output flow velocity conditions

  16. Estructuras de elevadores de carga. // Dumbwaiter structure stress analysis.

    Directory of Open Access Journals (Sweden)

    G. Escobar Travieso

    2004-05-01

    Full Text Available Este trabajo tiene como objetivo analizar las tensiones y deformaciones que ocurren en las estructuras del marco de carro,plataforma y cabina de elevadores de carga mediante la aplicación del Método de los Elementos Finitos, específicamentedel montaplatos de 300 Kg. de capacidad, con vista a realizar el análisis de resistencia, racionalización del peso y material ylas posibles vías de solución.Palabras claves: Elevador de carga, estructuras, análisis de tensiones, elementos finitos._______________________________________________________________________________AbstractThis paper deals with the tension and deformation analysis in structures of lifter mark, platform and cabin offreight lifters by means of the Finite Elements Method, specifically the 300 kgs capacity dumbwaiter, in orderto carry out the resistance analysis, weight and material rationalization.Key words: Dumbwaiter, structures, stress analysis, finite elements.

  17. Stress

    Science.gov (United States)

    ... taking care of an aging parent. With mental stress, the body pumps out hormones to no avail. Neither fighting ... with type 1 diabetes. This difference makes sense. Stress blocks the body from releasing insulin in people with type 2 ...

  18. Parametric analysis of stress in the ICF HYLIFE converter structure

    International Nuclear Information System (INIS)

    Hovingh, J.; Blink, J.A.

    1980-10-01

    The concept of a liquid-metal first wall in an ICF energy converter has a particularly attractive feature: the liquid metal absorbs the short-ranged fusion energy and moderates and attenuates the neutron energy so that the converter structure may have a lifetime similar to that of a conventional power plant. However, the sudden deposition of fusion energy in the liquid-metal first wall will result in disassembly of the liquid, which then impacts on the structure. The impact pressure on the structure is a strong function of the location and thickness of the liquid-metal first wall. The impact stress is determined by the impact pressure and duration and by the thickness and location of the structure. The maximum allowable stress is determined by the design stress criteria chosen by the structural designer. Scaling laws for the impact pressure as a function of the liquid-metal first wall location and mass are presented for a 2700 MW(f) (fusion power) plant with either one or four fusion reactor vessels. A methodology for determining the optimum combination of liquid-metal first wall geometry and first-structural-wall thickness is shown. Based on the methodology developed, a parametric analysis is presented of the liquid-metal flow rate and first-structural-wall requirements

  19. Stress analysis of plate-fin structures in recuperator

    International Nuclear Information System (INIS)

    Matsui, Shingo; Muto, Yasushi; Shiina, Yasuaki

    2001-01-01

    A high performance compact recuperator with 95% effectiveness is required to achieve a high thermal efficiency power generation of up to 50% in High Temperature Gas Cooled Reactor (HTGR) coupled with closed cycle helium gas turbine. Though a plate-fin type heat exchanger is proposed for this recuperator, much research and development works are needed to establish this high performance goal since there exists no state-of-the-art technology in such a high pressure and high temperature one. One of the important works is to establish the structural analysis and evaluation method in this plate-fin type heat exchanger. This paper describes the results of stress analysis of the plate-fin structure under the internal pressure as the first step of this work. First, the modeling of a unit plate-fin structure for the analysis was examined and a three layers model was confirmed to be most adequate. The stress distribution within the structure was clarified by using this model. Second, the three layers model was simplified to one layer model with sufficient accuracy. By using this model, both the effects of an inclined angle of fin and a thickness of separate on the strength were examined parametrically. Under the relevant design conditions, it was revealed that the optimum inclined angle of fin locates in the neighborhood of 76 degree rather than most difficult fabrication angle 90 degree and there is possibility to adopt thinner thickness than 0.5 mm in the current design. (author)

  20. How Do You #relax When You're #stressed? A Content Analysis and Infodemiology Study of Stress-Related Tweets.

    Science.gov (United States)

    Doan, Son; Ritchart, Amanda; Perry, Nicholas; Chaparro, Juan D; Conway, Mike

    2017-06-13

    Stress is a contributing factor to many major health problems in the United States, such as heart disease, depression, and autoimmune diseases. Relaxation is often recommended in mental health treatment as a frontline strategy to reduce stress, thereby improving health conditions. Twitter is a microblog platform that allows users to post their own personal messages (tweets), including their expressions about feelings and actions related to stress and stress management (eg, relaxing). While Twitter is increasingly used as a source of data for understanding mental health from a population perspective, the specific issue of stress-as manifested on Twitter-has not yet been the focus of any systematic study. The objective of our study was to understand how people express their feelings of stress and relaxation through Twitter messages. In addition, we aimed at investigating automated natural language processing methods to (1) classify stress versus nonstress and relaxation versus nonrelaxation tweets, and (2) identify first-hand experience-that is, who is the experiencer-in stress and relaxation tweets. We first performed a qualitative content analysis of 1326 and 781 tweets containing the keywords "stress" and "relax," respectively. We then investigated the use of machine learning algorithms-in particular naive Bayes and support vector machines-to automatically classify tweets as stress versus nonstress and relaxation versus nonrelaxation. Finally, we applied these classifiers to sample datasets drawn from 4 cities in the United States (Los Angeles, New York, San Diego, and San Francisco) obtained from Twitter's streaming application programming interface, with the goal of evaluating the extent of any correlation between our automatic classification of tweets and results from public stress surveys. Content analysis showed that the most frequent topic of stress tweets was education, followed by work and social relationships. The most frequent topic of relaxation tweets

  1. Profiled Roller Stress/Fatigue Life Analysis Methodology and Establishment of an Appropriate Stress/Life Exponent

    Science.gov (United States)

    1997-01-01

    The objective of this work was to determine the three dimensional volumetric stress field, surface pressure distribution and actual contact area between a 0.50" square roller with different crown profiles and a flat raceway surface using Finite Element Analysis. The 3-dimensional stress field data was used in conjunction with several bearing fatigue life theories to extract appropriate values for stress-life exponents. Also, results of the FEA runs were used to evaluate the laminated roller model presently used for stress and life prediction.

  2. Caries detection in dental radiographs

    International Nuclear Information System (INIS)

    Dunn, S.M.

    1987-01-01

    Caries, or the decay of teeth are difficult to automatically detect in dental radiographs because of the small area of the image that is occupied by the decay. Images of dental radiographs has distinct regions of homogeneous gray levels, and therefore naturally lead to a segmentation based automatic caries detection algorithm. This paper describes a method for caries detection based on a multiclass, area independent thresholding and segmenting scheme. This multiclass thresholding algorithm is an extension of the uniform error threshold, an area independent, distribution free thresholding method used for images of only two classes of objects. The authors first consider the problem of caries detection and the image features that characterize the presence of caries. Next, the uniform error threshold is reviewed, and the general multiclass uniform error threshold algorithm is presented. This algorithm is used to automatically detect caries in dental radiographs

  3. Interpretation and evaluation of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    After digestion, the interpreter must interpreted and evaluate the image on film, usually many radiograph stuck in this step, if there is good density, so there are no problem. This is a final stage of radiography work and this work must be done by level two or three radiographer. This is a final stages before the radiographer give a result to their customer for further action. The good interpreter must know what kind of artifact, is this artifact are dangerous or not and others. In this chapter, the entire artifact that usually showed will be discussed briefly with the good illustration and picture to make the reader understand and know the type of artifact that exists.

  4. Industrial radiography on radiographic paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1977-11-01

    An investigation was performed to compare the quality of radiographic paper with that of X-ray film, after a review had been made of the rather scarce literature on the subject. The equipment used throughout the investigation is described, and characteristic curves for Agfa-Gevaert and Kodak papers exposed with different intensifying screens in the low and intermediate voltage range are reproduced. The relative speed, contrast and exposure latitude were computed from these curves. The quality of the radiographic image was checked on U/Al blocks and plates, Al and Fe blocks, and fiber-reinforced composites. Exposure charts for Al and Fe were made for various paper and screen combinations. Both the sharpness of the radiographic image as well as the influence of processing on speed and contrast were checked. Examples are given of the practical application of the paper for radiography of castings, weldings, solderings, assemblies, etc. (author)

  5. On stress analysis of a crack-layer

    Science.gov (United States)

    Chudnovsky, A.; Dolgopolsky, A.; Kachanov, M.

    1984-01-01

    This work considers the problem of elastic interaction of a macrocrack with an array of microcracks in the vicinity of the macrocrack tip. Using the double layer potential techniques, the solution to the problem within the framework of the plane problem of elastostatics has been obtained. Three particular problems of interest to fracture mechanics have been analyzed. It follows from analysis that microcrack array can either amplify or reduce the resulting stress field of the macrocrack-microcrack array system depending on the array's configuration. Using the obtained elastic solution the energy release rate associated with the translational motion of the macrocrack-microcrack array system has been evaluated.

  6. SIGMARZ, Stress Analysis of Axisymmetric or Plane Structures

    International Nuclear Information System (INIS)

    1978-01-01

    1 - Nature of the physical problem solved: Classic stress analysis program for axisymmetric or plane geometric structures. 2 - Method of solution: The finite element method is used. Input are the finite element nodes, the imposed displacements, the applied forces at the nodes and the volumetric distributed forces. The linear equation system is solved by the Cholesky method. 3 - Restrictions on the complexity of the problem: Maximum number of nodes: 800; Maximum number of elements: 1300; Maximum number of displacements: 300; Maximum band width: 72

  7. Stress analysis of CVD diamond window for ECH system

    International Nuclear Information System (INIS)

    Takahashi, Koji

    2001-03-01

    The stress analysis of a chemical vapor deposition (CVD) diamond window for Electron Cyclotron Heating and Current Drive (ECH/ECCD) system of fusion reactors is described. It was found that the real size diamond window (φ aper =70mm, t=2.25mm) withstood 14.5 atm. (1.45 MPa). The calculation results of the diamond window by ABAQUS code agree well with the results of the pressure test. The design parameters of the torus diamond window for a vacuum and a safety barrier were also obtained. (author)

  8. Analysis of Stress Updates in the Material-point Method

    DEFF Research Database (Denmark)

    Andersen, Søren; Andersen, Lars

    2009-01-01

    The material-point method (MPM) is a new numerical method for analysis of large strain engineering problems. The MPM applies a dual formulation, where the state of the problem (mass, stress, strain, velocity etc.) is tracked using a finite set of material points while the governing equations...... are solved on a background computational grid. Several references state, that one of the main advantages of the material-point method is the easy application of complicated material behaviour as the constitutive response is updated individually for each material point. However, as discussed here, the MPM way...

  9. A different approach to X-ray stress analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ogilvie, Robert E. [Massachusetts Institute of Technology, Room 13-5065, 77 Massachusetts Ave., Cambridge, MA (United States)], E-mail: bobogil@mit.edu

    2007-07-15

    A different approach to X-ray stress analysis has been developed. At the outset, it must be noted that the material to be analyzed is assumed homogeneous and isotropic. If a sphere with radius r within a specimen is subjected to a state of stress, the sphere is deformed into an ellipsoid. The semi-axes of the ellipsoid have the values of (r + {epsilon}{sub x}), (r + {epsilon}{sub y}), and (r + {epsilon}{sub z}), which are replaced by d{sub x}, d{sub y}, and d{sub z}, or for the cubic case, a{sub x}, a{sub y}, and a{sub z}. In this technique, at a particular {phi} angle (see ), the two-theta position of a high angle (hkl) peak is determined at {psi} angles of 0, 15, 30, and 45{sup o}. These measurements are repeated for 3 to 6 {phi} angles in steps of 30{sup o}. The d{sub {phi}}{sub {psi}} or a{sub {phi}}{sub {psi}} values are then determined from the peak positions. The data is then fitted to the general quadratic equation for an ellipsoid by the method of least squares. From the coefficients of the quadratic equation, the angle between the laboratory and the specimen coordinates (direction of the principle stress) can be determined. Applying the general rotation of axes equations to the quadratic, the equation of the ellipse in the x-y plane is determined. The a{sub x}, a{sub y}, and a{sub z} values for the principal axes of the lattice parameter ellipsoid are then evaluated. It is then possible to determine the unstressed a{sub 0} value from Hooke's Law using a{sub x}, a{sub y}, and a{sub z}. The magnitude of the principal strains/stresses is then determined.

  10. Reflections on the role of consultant radiographers in the UK: What is a consultant radiographer?

    International Nuclear Information System (INIS)

    Booth, L.; Henwood, S.; Miller, P.

    2016-01-01

    Context: This paper is the second paper from a two year in depth case study, exploring the role of consultant radiographers in the UK. Methods: A longitudinal case study approach was used to determine the role of consultant radiographers. Interviews were used to explore experiences of being a consultant, which were analysed using thematic analysis. Eight consultant radiographers participated (Note, two of the consultants withdrew after the first interview due to workload). Therefore two consultants were interviewed only once. The remaining six consultants were interviewed twice over a 12 month period. Findings: The data presented in this paper explores the nature of the role, differences between roles, the four domains of practice, and how the role fits into local organisational structures. The study shows wide variation in the types of roles undertaken, reflecting that the creation of these roles were in response to local clinical need and often related to an individual practitioner's skills. The broad scope of the role was shown across all the consultants, with evidence of roles developing into new areas of service delivery. Conclusions: The paper offers insight into the role(s) of consultant radiographers in the UK. The range and scope of their practice is extensive, with much variation. It is evident that the clinical aspect of the role dominates, with research being the least supported domain of practice. There remains a lack of clarity around the role, with concerns about remuneration and other limitations that may restrict the role developing further. - Highlights: • This paper shows the variation in roles between consultant radiographers. • The commonality with medical roles is highlighted. • Problem solving is identified as a core skill in consultant radiography. • Consultants offered evidence of the roles developing service provision. • While all four domains of practice are covered, research is the least well supported.

  11. Analysis of Stress-Responsive Gene Expression in Cultivated and Weedy Rice Differing in Cold Stress Tolerance.

    Directory of Open Access Journals (Sweden)

    Caroline Borges Bevilacqua

    Full Text Available Rice (Oryza sativa L. cultivars show impairment of growth in response to environmental stresses such as cold at the early seedling stage. Locally adapted weedy rice is able to survive under adverse environmental conditions, and can emerge in fields from greater soil depth. Cold-tolerant weedy rice can be a good genetic source for developing cold-tolerant, weed-competitive rice cultivars. An in-depth analysis is presented here of diverse indica and japonica rice genotypes, mostly weedy rice, for cold stress response to provide an understanding of different stress adaptive mechanisms towards improvement of the rice crop performance in the field. We have tested a collection of weedy rice genotypes to: 1 classify the subspecies (ssp. grouping (japonica or indica of 21 accessions; 2 evaluate their sensitivity to cold stress; and 3 analyze the expression of stress-responsive genes under cold stress and a combination of cold and depth stress. Seeds were germinated at 25°C at 1.5- and 10-cm sowing depth for 10d. Seedlings were then exposed to cold stress at 10°C for 6, 24 and 96h, and the expression of cold-, anoxia-, and submergence-inducible genes was analyzed. Control plants were seeded at 1.5cm depth and kept at 25°C. The analysis revealed that cold stress signaling in indica genotypes is more complex than that of japonica as it operates via both the CBF-dependent and CBF-independent pathways, implicated through induction of transcription factors including OsNAC2, OsMYB46 and OsF-BOX28. When plants were exposed to cold + sowing depth stress, a complex signaling network was induced that involved cross talk between stresses mediated by CBF-dependent and CBF-independent pathways to circumvent the detrimental effects of stresses. The experiments revealed the importance of the CBF regulon for tolerance to both stresses in japonica and indica ssp. The mechanisms for cold tolerance differed among weedy indica genotypes and also between weedy indica and

  12. Influence of Stress Shape Function on Analysis of Contact Problem Using Hybrid Photoelasticity

    International Nuclear Information System (INIS)

    Shin, Dongchul; Hawong, Jaisug

    2013-01-01

    In this research, a study on stress shape functions was conducted to analyze the contact stress problem by using a hybrid photoelasticity. Because the contact stress problem is generally solved as a half-plane problem, the relationship between two analytical stress functions, which are compositions of the Airy stress function, was similar to one of the crack problem. However, this relationship in itself could not be used to solve the contact stress problem (especially one with singular points). Therefore, to analyze the contact stress problem more correctly, stress shape functions based on the condition of two contact end points had to be considered in the form of these two analytical stress functions. The four types of stress shape functions were related to the stress singularities at the two contact end points. Among them, the primary two types used for the analysis of an O-ring were selected, and their validities were verified in this work

  13. Stress Analysis of Single Spacer Grid Support considering Fuel Rod

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Y. G.; Jung, D. H.; Kim, J. H. [Chungnam National University, Daejeon (Korea, Republic of); Park, J. K.; Jeon, K. L. [Korea Nuclear Fuel, Daejeon (Korea, Republic of)

    2010-10-15

    Pressurized water reactor (PWR) nuclear fuel assembly is mainly composed of a top-end piece, a bottom-end piece, lots of fuel rods, and several spacer grids. Among them, the main function of spacer grid is protecting fuel rods from Fluid Induced Vibration (FIV). The cross section of spacer grid assembled by laser welding in upper and lower point. When the fuel rod inserted in spacer gird, spring and dimple and around of welded area got a stresses. The main hypothesis of this analysis is the boundary area of HAZ and base metal can get a lot of damage than other area by FIV. So, design factors of spacer grid mainly considered to preventing the fatigue failure in HAZ and spring and dimple of spacer grid. From previous researching, the environment in reactor verified. Pressure and temperature of light water observed 15MPa and 320 .deg. C, and vibration of the fuel rod observed within 0 {approx} 50Hz. In this study, mechanical properties of zirconium alloy that extracted from the test and the spacer grid model which used in the PWR were applied in stress analyzing. General-purpose finite element analysis program was used ANSYS Workbench 12.0.1 version. 3-D CAD program CATIA was used to create spacer grid model

  14. Paint coating characterization for thermoelastic stress analysis of metallic materials

    International Nuclear Information System (INIS)

    Robinson, A F; Dulieu-Barton, J M; Quinn, S; Burguete, R L

    2010-01-01

    In thermoelastic stress analysis (TSA) it is normal practice to coat metallic specimens with black paint to enhance and standardize the surface emissivity. It is assumed that the paint coating has no effect on the thermal emission from the specimen, but it is well known that the response is sensitive to paint coating thickness, particularly at higher frequencies. In this paper the effects of loading frequency and paint coating thickness on the thermoelastic response are investigated. The thermoelastic response is compared to theory, and optimum test conditions and coating characteristics are suggested. The motivation for the work is to develop a TSA-based means of residual stress assessment, where the measurement of much smaller temperature changes than those that are resolved in standard TSA is required; therefore the analysis is much more sensitive to the effects of the paint coating. However, the work presented in this paper is relevant to a wide range of TSA investigations and presents data that will be of interest to all practitioners of TSA

  15. Thermal stress analysis of the fuel storage facility

    International Nuclear Information System (INIS)

    Chen, W.W.

    1991-12-01

    This paper presents the results of a nonlinear finite-element analysis to determine the structural integrity of the walls of the nuclear fuel storage room in the Radio Isotope Power System Facility of the Fuels and Materials Examination Facility (FMEF) Project. The analysis was performed to assess the effects of thermal loading on the walls that would result from a loss-of-cooling accident. The results obtained from using the same three-dimensional finite-element model with different types of elements, the eight-node brick element and the nonlinear concrete element, and the calculated results using the analytical solutions, are compared. The concrete responses in terms of octahedral normal and shearing stresses are described. The crack and crush states of the concrete were determined on the basis of multiaxial failure criteria

  16. The stress analysis method for three-dimensional composite materials

    Science.gov (United States)

    Nagai, Kanehiro; Yokoyama, Atsushi; Maekawa, Zen'ichiro; Hamada, Hiroyuki

    1994-05-01

    This study proposes a stress analysis method for three-dimensionally fiber reinforced composite materials. In this method, the rule-of mixture for composites is successfully applied to 3-D space in which material properties would change 3-dimensionally. The fundamental formulas for Young's modulus, shear modulus, and Poisson's ratio are derived. Also, we discuss a strength estimation and an optimum material design technique for 3-D composite materials. The analysis is executed for a triaxial orthogonally woven fabric, and their results are compared to the experimental data in order to verify the accuracy of this method. The present methodology can be easily understood with basic material mechanics and elementary mathematics, so it enables us to write a computer program of this theory without difficulty. Furthermore, this method can be applied to various types of 3-D composites because of its general-purpose characteristics.

  17. Generation of spectra and stress histories for fatigue and damage tolerance analysis of fuselage repairs

    Science.gov (United States)

    1991-10-01

    This report describes a simplified procedure for the development of stress histories : for use in the analysis of aircraft repairs.- Although repairs of all components of : the airframe are of interest, this report concentrates on stress histories fo...

  18. Radiographic markers for measuring tibial rotation based on CT-reconstructed radiographs. An accuracy and feasibility study

    International Nuclear Information System (INIS)

    Hakimian, David; Khoury, Amal; Mosheiff, Rami; Liebergall, Meir; Weil, Yoram A.

    2018-01-01

    Malreduction in the axial plane (malrotation) following tibial fracture surgery is often undiagnosed. A few clinical and radiographic methods have been proposed for measuring tibial rotation intraoperatively, yet have failed to match the accuracy of computed tomography (CT). The aim of this study was to develop radiographic tools for future intraoperative assessment of the tibial shaft rotation profile. The setting was a laboratory computerized analysis. Twenty lower limb CT scans were used to construct a three-dimensional (3D) model using AMIRA copyright software. A virtual 3D cylinder was implanted in the posterior condylar line and in the transmalleolar axis. The 3D models were used to simulate four standard knee and ankle plain radiographs. On each radiograph, four landmarks were depicted by two observers and their relation with the cylinder was measured and analyzed for accuracy and reproducibility. A cadaveric lower leg was implanted with two Kirschner wires. A CT scan was performed in addition to 2D fluoroscopy. The simulated radiographs and the fluoroscopy were compared for accuracy. Measurement of the landmarks showed reliability in most of the knee anteroposterior and ankle mortise radiographs (coefficients of variation < 0.01 and = 0.01) respectively. Cadaveric measurement of the landmarks using real fluoroscopy and simulated radiographs were similar. To date, no reliable and common methods have been reported for the evaluation of tibial axial rotation. We propose a model in which simple radiographic landmarks can be used to calculate a 3D coordinate system that accurately assesses the axial rotation angle of the tibial shaft. (orig.)

  19. Radiographic markers for measuring tibial rotation based on CT-reconstructed radiographs. An accuracy and feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Hakimian, David; Khoury, Amal; Mosheiff, Rami; Liebergall, Meir; Weil, Yoram A. [Hadassah Hebrew University Hospital, Department of Orthopaedics, Jerusalem (Israel)

    2018-04-15

    Malreduction in the axial plane (malrotation) following tibial fracture surgery is often undiagnosed. A few clinical and radiographic methods have been proposed for measuring tibial rotation intraoperatively, yet have failed to match the accuracy of computed tomography (CT). The aim of this study was to develop radiographic tools for future intraoperative assessment of the tibial shaft rotation profile. The setting was a laboratory computerized analysis. Twenty lower limb CT scans were used to construct a three-dimensional (3D) model using AMIRA copyright software. A virtual 3D cylinder was implanted in the posterior condylar line and in the transmalleolar axis. The 3D models were used to simulate four standard knee and ankle plain radiographs. On each radiograph, four landmarks were depicted by two observers and their relation with the cylinder was measured and analyzed for accuracy and reproducibility. A cadaveric lower leg was implanted with two Kirschner wires. A CT scan was performed in addition to 2D fluoroscopy. The simulated radiographs and the fluoroscopy were compared for accuracy. Measurement of the landmarks showed reliability in most of the knee anteroposterior and ankle mortise radiographs (coefficients of variation < 0.01 and = 0.01) respectively. Cadaveric measurement of the landmarks using real fluoroscopy and simulated radiographs were similar. To date, no reliable and common methods have been reported for the evaluation of tibial axial rotation. We propose a model in which simple radiographic landmarks can be used to calculate a 3D coordinate system that accurately assesses the axial rotation angle of the tibial shaft. (orig.)

  20. Radiographic testing in concrete structures

    International Nuclear Information System (INIS)

    Oliveira, D. de

    1987-01-01

    The radiographic testing done in concrete structures is used to analyse the homogeneity, position and corrosion of armatures and to detect discontinuity in the concrete such as: gaps, cracks and segregations. This work develops a Image quality Indicator (IQI) with an adequated sensibility to detect discontinuites based on BS4408 norm. (E.G.) [pt

  1. Thermomechanical analysis of Natural Rubber behaviour stressed at room temperature.

    Directory of Open Access Journals (Sweden)

    Chrysochoos A.

    2010-06-01

    Full Text Available Owing to their high molecular mobility, stressed rubber chains can easily change their conformations and get orientated. This phenomena leads to so high reversible draw ratio that this behaviour is called rubber elasticity [1-3]. The analogy with ideal gases leads to an internal energy independent of elongation, the stress being attributed to a so-called configuration entropy. However, this analysis cannot take thermal expansion into account and moreover prohibits predicting standard thermo-elastic effect noticed at small elongations and the thermoelastic inversion effects [4]. This paper aims at : observing and quantifying dissipative and coupling effects associated with deformation energy, generated when Natural Rubber is stretched. re-examine the thermomechanical behaviour model of rubberlike materials, under the generalised standard material concept. From an experimental viewpoint, energy balance is created using infrared and quantitative imaging techniques. Digital Image Correlation (DIC provides in-the-plane displacement fields and, after derivation, strain and strain-rate fields. We have used those techniques to evidence the thermoelastic inversion effect as shown on Figure 1 where different weights have been fixed to warmed specimen and we monitored the sample deformation while it recovers room temperature. But we have also used those techniques to perform energy balance : analysis of the mechanical equilibrium allows estimates of the stress pattern and computation of deformation energy rates under a plane stress hypothesis [5]. Infrared Thermography (IRT gives the surface temperature of the sample. To estimate the distribution of heat sources, image processing with a local heat equation and a minimal set of approximation functions (image filtering was used. The time courses of deformation energy and heat associated with cyclic process are plotted in Figure 2. The time derivatives of both forms of energy are approximately similar. This

  2. Stress relaxation analysis and irradiation creep and swelling in pressure tubes

    International Nuclear Information System (INIS)

    Beeston, J.M.; Burr, T.K.

    1979-01-01

    An analysis is presented of slit width test information on two pressure tubes that had been irradiated in test reactors. The analysis showed that differential swelling stresses and thermal stresses undergo relaxation. The mechanism responsible for the stress relaxation at temperatures less than 700 K was irradiation creep. Irradiation creep in thermal test reactor pressure tubes is evidently greater than it would be at equivalent conditions in fast reactors. The residual stresses observed in the slit width tests varied between 30 and 257 MPa and would act to reduce the operating stresses, thus allowing for increased service life of the tubes as compared with no stress relaxation

  3. Stress analysis in curved composites due to thermal loading

    Science.gov (United States)

    Polk, Jared Cornelius

    Many structures in aircraft, cars, trucks, ships, machines, tools, bridges, and buildings, consist of curved sections. These sections vary from straight line segments that have curvature at either one or both ends, segments with compound curvatures, segments with two mutually perpendicular curvatures or Gaussian curvatures, and segments with a simple curvature. With the advancements made in multi-purpose composites over the past 60 years, composites slowly but steadily have been appearing in these various vehicles, compound structures, and buildings. These composite sections provide added benefits over isotropic, polymeric, and ceramic materials by generally having a higher specific strength, higher specific stiffnesses, longer fatigue life, lower density, possibilities in reduction of life cycle and/or acquisition cost, and greater adaptability to intended function of structure via material composition and geometry. To be able to design and manufacture a safe composite laminate or structure, it is imperative that the stress distributions, their causes, and effects are thoroughly understood in order to successfully accomplish mission objectives and manufacture a safe and reliable composite. The objective of the thesis work is to expand upon the knowledge of simply curved composite structures by exploring and ascertaining all pertinent parameters, phenomenon, and trends in stress variations in curved laminates due to thermal loading. The simply curved composites consist of composites with one radius of curvature throughout the span of the specimen about only one axis. Analytical beam theory, classical lamination theory, and finite element analysis were used to ascertain stress variations in a flat, isotropic beam. An analytical method was developed to ascertain the stress variations in an isotropic, simply curved beam under thermal loading that is under both free-free and fixed-fixed constraint conditions. This is the first such solution to Author's best knowledge

  4. Radiographic detection of IGSCC

    International Nuclear Information System (INIS)

    Schonberg, R.G.

    1985-01-01

    One of the most troubling problems which the Nuclear Industry faces is Intergranular Stress Corrosion Cracking on BWR reactors. The detection and repair of pipe welds exhibiting possible flaws can easily exceed $100,000,000.00 (one hundred million dollars) per reactor, if a complete pipe replacement is necessary. Most of the detection work has involved use of ultrasonics to locate and in some cases approximate flaw depth. In Service inspection (ISI) of primary nuclear piping by means of radiography has not been possible in most cases because of the presence of relatively high background dose rates. Neither Iridium 192 or Cobalt 60 can be used for small wall pipe thicker than approximately 5 cm where background radiation exceeds 1 R/hr and the distance is about 1 meter F.F.D. through double wall water filled pipe. The other problem is meeting code requirements for penetrameter sensitivity with the large source size of a Cobalt source such as a 100 curies unit. Development of the MINAC, a highly portable high energy X-ray source, makes field radiography possible on thick section piping. Radiography through total steel thicknesses of up to 300 mm has been done with a 45 minute exposure with an F.F.D. of 1.6 meters. The delivered dose to the film was 2.0 Rads and produced a film density of 2.5 on Kodak AA film. Feasibility of use of the 4 MeV MINAC for high quality film radiography has been established. The focal spot size is 1.7 mm which assures good resolution even where short F.F.D.s are employed

  5. Normal radiographic findings. 4. act. ed.

    International Nuclear Information System (INIS)

    Moeller, T.B.

    2003-01-01

    This book can serve the reader in three ways: First, it presents normal findings for all radiographic techniques including KM. Important data which are criteria of normal findings are indicated directly in the pictures and are also explained in full text and in summary form. Secondly, it teaches the systematics of interpreting a picture - how to look at it, what structures to regard in what order, and for what to look in particular. Checklists are presented in each case. Thirdly, findings are formulated in accordance with the image analysis procedure. All criteria of normal findings are defined in these formulations, which make them an important didactic element. (orig.)

  6. Normal radiographic findings. 4. act. ed.; Roentgennormalbefunde

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, T.B. [Gemeinschaftspraxis fuer Radiologie und Nuklearmedizin, Dillingen (Germany)

    2003-07-01

    This book can serve the reader in three ways: First, it presents normal findings for all radiographic techniques including KM. Important data which are criteria of normal findings are indicated directly in the pictures and are also explained in full text and in summary form. Secondly, it teaches the systematics of interpreting a picture - how to look at it, what structures to regard in what order, and for what to look in particular. Checklists are presented in each case. Thirdly, findings are formulated in accordance with the image analysis procedure. All criteria of normal findings are defined in these formulations, which make them an important didactic element. (orig.)

  7. Educational and experiential effects on radiographers' radiation safety behavior

    International Nuclear Information System (INIS)

    Tilson, E.R.

    1982-01-01

    Forty-four radiographers from 11 hospitals in Northern California were observed for radiation safety behaviors in six categories. A multiple regression analysis was performed to determine if there was a significant relationship between the six radiation safety behaviors and the radiographer's age, sex, type of professional training, years since completion of professional training, years of professional practice, time of day, and exposure frequency. The multiple regression analysis showed that there was a significant relationship between use of gonadal shielding and years since completion of professional training, years of professional practice, type of training, and age. The multiple regression analysis also showed that the number of repeated films due to technical error was significantly related to the type of professional training a radiographer received

  8. Stress analysis and deformation prediction of sheet metal workpieces based on finite element simulation

    Directory of Open Access Journals (Sweden)

    Ren Penghao

    2017-01-01

    Full Text Available After aluminum alloy sheet metal parts machining, the residual stress release will cause a large deformation. To solve this problem, this paper takes a aluminum alloy sheet aerospace workpiece as an example, establishes the theoretical model of elastic deformation and the finite element model, and places quantitative initial stress in each element of machining area, analyses stress release simulation and deformation. Through different initial stress release simulative analysis of deformation of the workpiece, a linear relationship between initial stress and deformation is found; Through simulative analysis of coupling direction-stress release, the superposing relationship between the deformation caused by coupling direction-stress and the deformation caused by single direction stress is found. The research results provide important theoretical support for the stress threshold setting and deformation controlling of the workpieces in the production practice.

  9. Numerical analysis of residual stresses reconstruction for axisymmetric glass components

    Science.gov (United States)

    Tao, Bo; Xu, Shuang; Yao, Honghui

    2018-01-01

    A non-destructive measurement method for 3D stress state in a glass cylinder using photoelasticity has been analyzed by simulation in this research. Based on simulated stresses in a glass cylinder, intensity of the cylinder in a circular polariscope can be calculated by Jones calculus. Therefore, the isoclinic angle and optical retardation can be obtained by six steps phase shifting technique. Through the isoclinic angle and optical retardation, the magnitude and distribution of residual stresses inside the glass cylinder in cylindrical coordinate system can be reconstructed. Comparing the reconstructed stresses with numerical simulated stresses, the results verify this non-destructive method can be used to reconstruct the 3D stresses. However, there are some mismatches in axial stress, radial stress and circumferential stress.

  10. HammerCloud: A Stress Testing System for Distributed Analysis

    International Nuclear Information System (INIS)

    Ster, Daniel C van der; García, Mario Úbeda; Paladin, Massimo; Elmsheuser, Johannes

    2011-01-01

    Distributed analysis of LHC data is an I/O-intensive activity which places large demands on the internal network, storage, and local disks at remote computing facilities. Commissioning and maintaining a site to provide an efficient distributed analysis service is therefore a challenge which can be aided by tools to help evaluate a variety of infrastructure designs and configurations. HammerCloud is one such tool; it is a stress testing service which is used by central operations teams, regional coordinators, and local site admins to (a) submit arbitrary number of analysis jobs to a number of sites, (b) maintain at a steady-state a predefined number of jobs running at the sites under test, (c) produce web-based reports summarizing the efficiency and performance of the sites under test, and (d) present a web-interface for historical test results to both evaluate progress and compare sites. HammerCloud was built around the distributed analysis framework Ganga, exploiting its API for grid job management. HammerCloud has been employed by the ATLAS experiment for continuous testing of many sites worldwide, and also during large scale computing challenges such as STEP'09 and UAT'09, where the scale of the tests exceeded 10,000 concurrently running and 1,000,000 total jobs over multi-day periods. In addition, HammerCloud is being adopted by the CMS experiment; the plugin structure of HammerCloud allows the execution of CMS jobs using their official tool (CRAB).

  11. HammerCloud: A Stress Testing System for Distributed Analysis

    CERN Document Server

    van der Ster, Daniel C; Ubeda Garcia, Mario; Paladin, Massimo

    2011-01-01

    Distributed analysis of LHC data is an I/O-intensive activity which places large demands on the internal network, storage, and local disks at remote computing facilities. Commissioning and maintaining a site to provide an efficient distributed analysis service is therefore a challenge which can be aided by tools to help evaluate a variety of infrastructure designs and configurations. HammerCloud (HC) is one such tool; it is a stress testing service which is used by central operations teams, regional coordinators, and local site admins to (a) submit arbitrary number of analysis jobs to a number of sites, (b) maintain at a steady-state a predefined number of jobs running at the sites under test, (c) produce web-based reports summarizing the efficiency and performance of the sites under test, and (d) present a web-interface for historical test results to both evaluate progress and compare sites. HC was built around the distributed analysis framework Ganga, exploiting its API for grid job management. HC has been ...

  12. Can Australian radiographers assess screening mammograms accurately? First stage results from a four year prospective study

    International Nuclear Information System (INIS)

    Moran, S.; Warren-Forward, H.

    2016-01-01

    Introduction: Globally, the role of the radiographer is changing; some countries have developed advanced roles with specific scopes of practice. Other countries, like Australia, are in the process of this change. The aim of this research is to assess the diagnostic outcomes reported by the radiographers and compare them to those reported by current screen readers. Method: Six experienced radiographers were invited to participate in a prospective study conducted between 2010 and 2011. They were required to read 2000 mammograms each. Their results were compared with those of the radiologists. Statistical analysis of the results included overall cancer detection rates, recall rates, levels of agreement, kappa, sensitivity, specificity, accuracy, positive predictive value and negative predictive value. Results: A total of 9348 women were included in the study. The percentage of cancers detected by the radiographers ranged from 53% to 100% of the cancers detected by the radiologists. Radiologist recall rate ranged between 3.4% and 5.5% and the radiographers' range was 2.9%–9.8%. Level of agreement of the radiographers with the radiologists ranged from 90 to 96%. Conclusion: The potential for accuracy in screen reading by Australian radiographers is supported by the results of this study. Implementation of formal training is likely to result in an increase in the diagnostic accuracy of radiographers. - Highlights: • Radiographers prospectively read 2000 screening mammograms each. • These results support potential for accuracy in screen reading by radiographers. • Will advanced practice be introduced within BreastScreen Australia?.

  13. Variability amongst radiographers in the categorization of clinical acceptability for digital trauma radiography

    Science.gov (United States)

    Decoster, Robin; Toomey, Rachel; Smits, Dirk; Mol, Harrie; Verhelle, Filip; Butler, Marie-Louise

    2016-03-01

    Introduction: Radiographers evaluate anatomical structures to judge clinical acceptability of a radiograph. Whether a radiograph is deemed acceptable for diagnosis or not depends on the individual decision of the radiographer. Individual decisions cause variation in the accepted image quality. To minimise these variations definitions of acceptability, such as in RadLex, were developed. On which criteria radiographers attribute a RadLex categories to radiographs is unknown. Insight into these criteria helps to further optimise definitions and reduce variability in acceptance between radiographers. Therefore, this work aims the evaluation of the correlation between the RadLex classification and the evaluation of anatomical structures, using a Visual Grading Analysis (VGA) Methods: Four radiographers evaluated the visibility of five anatomical structures of 25 lateral cervical spine radiographs on a secondary class display with a VGA. They judged clinical acceptability of each radiograph using RadLex. Relations between VGAS and RadLex category were analysed with Kendall's Tau correlation and Nagelkerke pseudo-R². Results: The overall VGA score (VGAS) and the RadLex score correlate (rτ= 0.62, pscore. The reproduction of spinous processes (rτ=0.67, pscore. Conclusion: RadLex scores and VGAS correlate positively, strongly and significantly. The predictive value of bony structures may support the use of these in the judgement of clinical acceptability. Considerable inter-observer variations in the VGAS within a certain RadLex category, suggest that observers use of observer specific cut-off values.

  14. Endodontic radiography: who is reading the digital radiograph?

    Science.gov (United States)

    Tewary, Shalini; Luzzo, Joseph; Hartwell, Gary

    2011-07-01

    Digital radiographic imaging systems have undergone tremendous improvements since their introduction. Advantages of digital radiographs over conventional films include lower radiation doses compared with conventional films, instantaneous images, archiving and sharing images easily, and manipulation of several radiographic properties that might help in diagnosis. A total of 6 observers including 2 endodontic residents, 3 endodontists, and 1 oral radiologist evaluated 150 molar digital periapical radiographs to determine which of the following conditions existed: normal periapical tissue, widened periodontal ligament, or presence of periapical radiolucency. The evaluators had full control over the radiograph's parameters of the Planmeca Dimaxis software program. All images were viewed on the same computer monitor with ideal vie-wing conditions. The same 6 observers evaluated the same 150 digital images 3 months later. The data were analyzed to determine how well the evaluators agreed with each other (interobserver agreement) for 2 rounds of observations and with themselves (intraobserver agreement). Fleiss kappa statistical analysis was used to measure the level of agreement among multiple raters. The overall Fleiss kappa value for interobserver agreement for the first round of interpretation was 0.34 (P value for interobserver agreement for the second round of interpretation was 0.35 (P fair (0.2-0.4) agreement among the 6 raters at both observation periods. A weighted kappa analysis was used to determine intraobserver agreement, which showed on average a moderate agreement. The results indicate that the interpretation of a dental radiograph is subjective, irrespective of whether conventional or digital radiographs are used. The factors that appeared to have the most impact were the years of experience of the examiner and familiarity of the operator with a given digital system. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All

  15. Evaluation of the styloid process on digital panoramic radiographs

    International Nuclear Information System (INIS)

    More, Chandramani B; Asrani, Mukesh K

    2010-01-01

    The styloid process is an anatomical structure, whose clinical importance is not well understood. Proper clinical and radiographic evaluation can detect an elongated styloid process and calcification of the stylohyoid ligament. It has been reported that 2 – 28% of the general population show radiographic evidence of mineralization of a portion of the stylohyoid chain. The elongated styloid process may be symptomatic in many cases. Panoramic radiography is the best imaging modality to view the styloid process bilaterally. To assess the styloid process on digital panoramic radiographs. The study was conducted on 500 digital panoramic radiographs available in the archives of our department as soft copies. These radiographs were taken using a digital panoramic system. The radiographic length of the styloid process was measured on both sides using the measurement toolbars on the accompanying analysis software. For statistical analysis we used the unpaired t test, Chi-square test, and one-way ANOVA test, as necessary. The average length of the left styloid was 25.41 ± 6.32 mm and that of the right styloid was 25.53 ± 6.62 mm. The length of both styloids increased with age and males had longer styloids than females. Elongated styloids were present in 19.4% of the panoramic radiographs. Langlais type I elongated styloids and a partial calcification pattern were more common than others. Panoramic radiography is useful for detection of an elongated styloid process and / or ossification of the stylohyoid ligament in patients with or without symptoms, and helps avoid a misdiagnosis of tonsillar pain or pain of dental, pharyngeal, or muscular origin

  16. Evaluation of the styloid process on digital panoramic radiographs

    Directory of Open Access Journals (Sweden)

    More Chandramani

    2010-01-01

    Full Text Available Background: The styloid process is an anatomical structure, whose clinical importance is not well understood. Proper clinical and radiographic evaluation can detect an elongated styloid process and calcification of the stylohyoid ligament. It has been reported that 2 - 28% of the general population show radiographic evidence of mineralization of a portion of the stylohyoid chain. The elongated styloid process may be symptomatic in many cases. Panoramic radiography is the best imaging modality to view the styloid process bilaterally. Aim: To assess the styloid process on digital panoramic radiographs. Materials and Methods: The study was conducted on 500 digital panoramic radiographs available in the archives of our department as soft copies. These radiographs were taken using a digital panoramic system. The radiographic length of the styloid process was measured on both sides using the measurement toolbars on the accompanying analysis software. For statistical analysis we used the unpaired t test, Chi-square test, and one-way ANOVA test, as necessary. Results: The average length of the left styloid was 25.41 ± 6.32 mm and that of the right styloid was 25.53 ± 6.62 mm. The length of both styloids increased with age and males had longer styloids than females. Elongated styloids were present in 19.4% of the panoramic radiographs. Langlais type I elongated styloids and a partial calcification pattern were more common than others. Conclusion: Panoramic radiography is useful for detection of an elongated styloid process and / or ossification of the stylohyoid ligament in patients with or without symptoms, and helps avoid a misdiagnosis of tonsillar pain or pain of dental, pharyngeal, or muscular origin.

  17. Importance of radiographic monitoring of endoscopic sphincterotomy

    International Nuclear Information System (INIS)

    Greenberg, H.M.; Goldberg, H.I.; Shapiro, H.A.

    1981-01-01

    The radiographic features of endoscopic sphincterotomies performed in 44 patients were evaluated. Radiographic landmarks aided in proper sphincterotome placement and also disclosed conditions and anatomic variations that made catheter placement difficult. Fluoroscopic and radiographic monitoring not only assisted the performance of endoscopic sphincterotomy, but also confirmed successful results and revealed reasons for failure. Radiographic changes in the biliary tract after sphincterotomy, as well as potential complications of sphincterotomy, are discussed and illustrated

  18. Analysis of Mechanical Stresses/Strains in Superconducting Wire

    Science.gov (United States)

    Barry, Matthew; Chen, Jingping; Zhai, Yuhu

    2016-10-01

    The optimization of superconducting magnet performance and development of high-field superconducting magnets will greatly impact the next generation of fusion devices. A successful magnet development, however, relies deeply on the understanding of superconducting materials. Among the numerous factors that impact a superconductor's performance, mechanical stress is the most important because of the extreme operation temperature and large electromagnetic forces. In this study, mechanical theory is used to calculate the stresses/strains in typical superconducting strands, which consist of a stabilizer, a barrier, a matrix and superconducting filaments. Both thermal loads and mechanical loads are included in the analysis to simulate operation conditions. Because this model simulates the typical architecture of major superconducting materials, such as Nb3Sn, MgB2, Bi-2212 etc., it provides a good overall picture for us to understand the behavior of these superconductors in terms of thermal and mechanical loads. This work was supported in part by the U.S. Department of Energy, Office of Science, Office of Workforce Development for Teachers and Scientists (WDTS) under the Science Undergraduate Laboratory Internship (SULI) program.

  19. Stress analysis in oral obturator prostheses: imaging photoelastic

    Science.gov (United States)

    Pesqueira, Aldiéris Alves; Goiato, Marcelo Coelho; dos Santos, Daniela Micheline; Haddad, Marcela Filié; Andreotti, Agda Marobo; Moreno, Amália

    2013-06-01

    Maxillary defects resulting from cancer, trauma, and congenital malformation affect the chewing efficiency and retention of dentures in these patients. The use of implant-retained palatal obturator dentures has improved the self-esteem and quality of life of several subjects. We evaluate the stress distribution of implant-retained palatal obturator dentures with different attachment systems by using the photoelastic analysis images. Two photoelastic models of the maxilla with oral-sinus-nasal communication were fabricated. One model received three implants on the left side of the alveolar ridge (incisive, canine, and first molar regions) and the other did not receive implants. Afterwards, a conventional palatal obturator denture (control) and two implant-retained palatal obturator dentures with different attachment systems (O-ring; bar-clip) were constructed. Models were placed in a circular polariscope and a 100-N axial load was applied in three different regions (incisive, canine, and first molar regions) by using a universal testing machine. The results were photographed and analyzed qualitatively using a software (Adobe Photoshop). The bar-clip system exhibited the highest stress concentration followed by the O-ring system and conventional denture (control). Images generated by the photoelastic method help in the oral rehabilitator planning.

  20. Residual stress analysis in BWR pressure vessel attachments

    International Nuclear Information System (INIS)

    Dexter, R.J.; Leung, C.P.; Pont, D.

    1992-06-01

    Residual stresses from welding processes can be the primary driving force for stress corrosion cracking (SCC) in BWR components. Thus, a better understanding of the causes and nature of these residual stresses can help assess and remedy SCC. Numerical welding simulation software, such as SYSWELD, and material property data have been used to quantify residual stresses for application to SCC assessments in BWR components. Furthermore, parametric studies using SYSWELD have revealed which variables significantly affect predicted residual stress. Overall, numerical modeling techniques can be used to evaluate residual stress for SCC assessments of BWR components and to identify and plan future SCC research

  1. The effect of perceived organizational support on organizational commitment of diagnostic imaging radiographers

    International Nuclear Information System (INIS)

    Makanjee, Chandra Rekha; Hartzer, Yolanda F.; Uys, Ilse L.

    2006-01-01

    This article arises from a research project investigating the effects of occupational stress and organizational commitment of diagnostic imaging radiographers on rendering quality service. One of the main aims of this project was to determine the extent to which perceived organizational support influenced commitment of radiographers to the organization, to reduce turnover intent and quality of service rendered. A descriptive correlation study design, based on questionnaires completed by 119 radiographers from 11 organizations, revealed that organizational commitment was moderate towards a tendency of poor. A positive relationship was found between various antecedents of perceived organizational support and organizational commitment (mainly affective and normative), indicating that perceived organizational support positively influenced radiographers' organizational commitment. There is a clear indication of turnover intent, which in turn has a negative impact on rendering quality service. In conclusion, to reduce turnover intent, and improve quality of service rendered, management needs to play an important role in creating a positive working environment for radiographers to perform their tasks

  2. Stress fractures

    International Nuclear Information System (INIS)

    Berquist, T.H.; Cooper, K.L.; Pritchard, D.J.

    1985-01-01

    The diagnosis of a stress fracture should be considered in patients presented with pain after a change in activity, especially if the activity is strenuous and the pain is in the lower extremities. Since evidence of the stress fracture may not be apparent for weeks on routine radiographs, proper use of other imaging techniques will allow an earlier diagnosis. Prompt diagnosis is especially important in the femur, where displacement may occur

  3. 21 CFR 892.1840 - Radiographic film.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film. 892.1840 Section 892.1840 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1840 Radiographic film. (a) Identification. Radiographic film is a device that consists of a thin sheet of radiotransparent material coated on one or both...

  4. Who are they? Identities in the Norwegian radiographer profession as presented in the Norwegian printed press

    International Nuclear Information System (INIS)

    Stalsberg, R.; Thingnes, E.R.

    2016-01-01

    Purpose: To explore how Norwegian radiographers are portrayed in written press. Method: Textual discourse analysis, following a multiple step strategy, combining both a quantitative and a qualitative approach. 189 newspaper articles were included. The articles were registered and subject fields were inductively categorized. Each subject field was analysed regarding the field's role as an agent of influence on public perception of radiographers. Results: On average, less than one article a year concerning radiography profession is published in Norwegian newspapers. A majority are published in newspapers with small circulation figures, often reporting on resources in the local health services where radiographers are involved. Mostly radiographers are placed in the articles' background playing supporting roles, frequently mentioned in the cutline as an operator of a new medical technology. There is a heavy emphasis on the technology, leaving the specialized expertise and radiography knowledge out. This focus persist in the instances where radiographers play a main role in the texts. When patient stories are told, positive value-laden words are used to describe the radiographer and both the technical and the patient-care aspects of being a radiographer are noticeable. Conclusion: Norwegian radiographers typically appear, in glimpses, as anonymous allied health technicians in local reports on new diagnostic equipment or resource utilization. The professional qualities and decisive skills required to handle sophisticated diagnostic equipment and continuity of patient care are underestimated. A more-nuanced media coverage might give radiographers a strengthened identity as important health-care service contributors. - Highlights: • The radiography profession is an inconspicuous topic in Norwegian written press. • Written press involving radiographers highlight new equipment and medical technology. • Radiographers' professional qualities and decisive

  5. Primitive Path Analysis and Stress Distribution in Highly Strained Macromolecules.

    Science.gov (United States)

    Hsu, Hsiao-Ping; Kremer, Kurt

    2018-01-16

    Polymer material properties are strongly affected by entanglement effects. For long polymer chains and composite materials, they are expected to be at the origin of many technically important phenomena, such as shear thinning or the Mullins effect, which microscopically can be related to topological constraints between chains. Starting from fully equilibrated highly entangled polymer melts, we investigate the effect of isochoric elongation on the entanglement structure and force distribution of such systems. Theoretically, the related viscoelastic response usually is discussed in terms of the tube model. We relate stress relaxation in the linear and nonlinear viscoelastic regimes to a primitive path analysis (PPA) and show that tension forces both along the original paths and along primitive paths, that is, the backbone of the tube, in the stretching direction correspond to each other. Unlike homogeneous relaxation along the chain contour, the PPA reveals a so far not observed long-lived clustering of topological constraints along the chains in the deformed state.

  6. Proteome analysis of soybean roots under waterlogging stress at an ...

    Indian Academy of Sciences (India)

    Prakash

    To gain better insight into how soybean roots respond to waterlogging stress, ... death- and signal transduction-related proteins suggest that they have a role to play during stress. ...... work cooperatively to establish a new homeostasis under.

  7. Finite element analysis of thermal stress distribution in different ...

    African Journals Online (AJOL)

    Nigerian Journal of Clinical Practice. Journal Home ... Von Mises and thermal stress distributions were evaluated. Results: In all ... distribution. Key words: Amalgam, finite element method, glass ionomer cement, resin composite, thermal stress ...

  8. Preliminary analysis of knee stress in Full Extension Landing

    Directory of Open Access Journals (Sweden)

    Majid Davoodi Makinejad

    2013-09-01

    Full Text Available OBJECTIVE: This study provides an experimental and finite element analysis of knee-joint structure during extended-knee landing based on the extracted impact force, and it numerically identifies the contact pressure, stress distribution and possibility of bone-to-bone contact when a subject lands from a safe height. METHODS: The impact time and loads were measured via inverse dynamic analysis of free landing without knee flexion from three different heights (25, 50 and 75 cm, using five subjects with an average body mass index of 18.8. Three-dimensional data were developed from computed tomography scans and were reprocessed with modeling software before being imported and analyzed by finite element analysis software. The whole leg was considered to be a fixed middle-hinged structure, while impact loads were applied to the femur in an upward direction. RESULTS: Straight landing exerted an enormous amount of pressure on the knee joint as a result of the body's inability to utilize the lower extremity muscles, thereby maximizing the threat of injury when the load exceeds the height-safety threshold. CONCLUSIONS: The researchers conclude that extended-knee landing results in serious deformation of the meniscus and cartilage and increases the risk of bone-to-bone contact and serious knee injury when the load exceeds the threshold safety height. This risk is considerably greater than the risk of injury associated with walking downhill or flexion landing activities.

  9. Defects quantization in industrial radiographs by image processing

    International Nuclear Information System (INIS)

    Briand, F.Y.; Brillault, B.; Philipp, S.

    1988-01-01

    This paper refers to the industrial application of image processing using Non Destructive Testing by radiography. The various problems involved by the conception of a numerical tool are described. This tool intends to help radiograph experts to quantify defects and to follow up their evolution, using numerical techniques. The sequences of processings that achieve defect segmentation and quantization are detailed. They are based on the thorough knowledge of radiographs formation techniques. The process uses various methods of image analysis, including textural analysis and morphological mathematics. The interface between the final product and users will occur in an explicit language, using the terms of radiographic expertise without showing any processing details. The problem is thoroughly described: image formation, digitization, processings fitted to flaw morphology and finally product structure in progress. 12 refs [fr

  10. Anti-citrullinated peptide antibodies are the strongest predictor of clinically relevant radiographic progression in rheumatoid arthritis patients achieving remission or low disease activity: A post hoc analysis of a nationwide cohort in Japan.

    Directory of Open Access Journals (Sweden)

    Tomohiro Koga

    Full Text Available To determine prognostic factors of clinically relevant radiographic progression (CRRP in patients with rheumatoid arthritis (RA achieving remission or low disease activity (LDA in clinical practice.Using data from a nationwide, multicenter, prospective study in Japan, we evaluated 198 biological disease-modifying antirheumatic drug (bDMARD-naïve RA patients who were in remission or had LDA at study entry after being treated with conventional synthetic DMARDs (csDMARDs. CRRP was defined as the yearly progression of modified total Sharp score (mTSS >3.0 U. We performed a multiple logistic regression analysis to explore the factors to predict CRRP at 1 year. We used receiver operating characteristic (ROC curve to estimate the performance of relevant variables for predicting CRRP.The mean Disease Activity Score in 28 joints-erythrocyte sedimentation rate (DAS28-ESR was 2.32 ± 0.58 at study entry. During the 1-year observation, remission or LDA persisted in 72% of the patients. CRRP was observed in 7.6% of the patients. The multiple logistic regression analysis revealed that the independent variables to predict the development of CRRP were: anti-citrullinated peptide antibodies (ACPA positivity at baseline (OR = 15.2, 95%CI 2.64-299, time-integrated DAS28-ESR during the 1 year post-baseline (7.85-unit increase, OR = 1.83, 95%CI 1.03-3.45, and the mTSS at baseline (13-unit increase, OR = 1.22, 95%CI 1.06-1.42.ACPA positivity was the strongest independent predictor of CRRP in patients with RA in remission or LDA. Physicians should recognize ACPA as a poor-prognosis factor regarding the radiographic outcome of RA, even among patients showing a clinically favorable response to DMARDs.

  11. Stress analysis of advanced attack helicopter composite main rotor blade root end lug

    Science.gov (United States)

    Baker, D. J.

    1982-01-01

    Stress analysis of the Advanced Attack Helicopter (AAH) composite main rotor blade root end lug is described. The stress concentration factor determined from a finite element analysis is compared to an empirical value used in the lug design. The analysis and test data indicate that the stress concentration is primarily a function of configuration and independent of the range of material properties typical of Kevlar-49/epoxy and glass epoxy.

  12. Pulp polyp - A periapical lesion: Radiographic observational study

    Directory of Open Access Journals (Sweden)

    Kandagal V Suresh

    2015-01-01

    Full Text Available Introduction: Pulp polyp (PP is a chronic hyperplastic condition resulting in formation of granulation tissue and proliferative mass. The radiographic appearance of PP has innumerable presentations. Diagnosing and treatment planning of periapical lesions, heavily relies on the radiographic changes surrounding the root structures. Objective: To evaluate different radiographic periapical changes in clinically detected PP patients. Materials and Methods: Patients reporting to Department of Oral Medicine and Radiology and who were clinically diagnosed with PP by an oral diagnostician were subjected to radiographic examination. Digital intraoral periapical radiographs of 50 patients with PP were taken. Various periapical changes in the digital radiographs were recorded by a skilled oral radiologist. The data obtained was subjected to statistical analysis using SPSS ver 17.0 and P-value was set at <0.05 as significant. Result: Periapical changes like periodontal space widening (PDLW, loss of lamina dura, periapical abscess, periapical granuloma, hypercementosis, condensing osteitis and root resorption were noted. Periodontal space widening was seen in all patients (100%, loss of lamina dura was noted in 72%, periapical rarefying osteitis in 56%, condensing osteitis in 8%, hypercementosis, periapical granuloma, and root resorption were seen in 4% of PP patients. Majority of PP were asymptomatic (66%. Pulp polyp was commonly seen in mandibular first molar followed by mandibular second molar and maxillary first molar. Statistically significant difference was noticed between periapical changes in PP patients (P value <0.0001. All PP patients showed definite periapical changes suggesting it to be a periapical lesion. Conclusion: Pulp polyp is confined to the pulpal portion of the tooth which, may or may not cause changes in periapical region. The results of the present study showed that majority of the PP patients were associated with definite periapical

  13. The analysis of stress reactions ana coping patterns of cancer patients who perceived stress by radiotherapy

    International Nuclear Information System (INIS)

    Bang, Dong Han; Kim, Jin Su; Park, Gil Yong; Son, Mi Suk

    2001-01-01

    This study is performed to encourage cancer patients to identify, relieve and effectively overcome the stress caused by radiotherapy, by analyzing stress reactions and coping patterns of cancer patients who perceived stress due to radiotherapy. The study group was composed of 85 cancer patients of the age 20 or higher who were undergoing radiotherapy in four hospitals located in Seoul and Kyonggi-do. The survey questionnaire was used, which had 161 questions inquiring respondents of general status, perceived stress, stress reactions and coping patterns. The surveyed data were analyzed by a SAS program, which employed descriptive statistics. Pearson Correlation Coefficient, t-test, ANOVA and Stepwised Multiple Regression. The stress perception and reaction rates were low in cancer patients comparing to patients of the other study. In the coping patterns. the problem-focused coping patterns were significantly higher than emotion-focused coping patterns. The statistically meaningful differences were observed in the stress perception and reactions depending on the time of diagnosis and perceived health level. As for the problem-focused coping patterns, significant differences were found depending on age, marital status, education, income and the number of family members as well as perceived health level of patients. The level of perceived stress and that of stress reactions was found to have positively significant correlation(r=.764, p<.001) while the perceived stress and the problem-focused coping patterns was correlated negatively (r=-.288, p<.01). The stress reactions and the problem-focused coping patterns was found to have negatively significant correlation(r=-.289, p<.01). The problem-focused coping behavior, which cooperated with doctors, technologists, nurses and families of cancer patients, is advisable for the cancer patients to overcome uncertainty and uneasiness by effectively release the stress.

  14. The analysis of stress reactions ana coping patterns of cancer patients who perceived stress by radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Dong Han; Kim, Jin Su; Park, Gil Yong; Son, Mi Suk [Dept. of Radiation Oncology, Bundang CHA General Hospital, College of Medicine, Pochon CHA University, Sungnam (Korea, Republic of)

    2001-12-15

    This study is performed to encourage cancer patients to identify, relieve and effectively overcome the stress caused by radiotherapy, by analyzing stress reactions and coping patterns of cancer patients who perceived stress due to radiotherapy. The study group was composed of 85 cancer patients of the age 20 or higher who were undergoing radiotherapy in four hospitals located in Seoul and Kyonggi-do. The survey questionnaire was used, which had 161 questions inquiring respondents of general status, perceived stress, stress reactions and coping patterns. The surveyed data were analyzed by a SAS program, which employed descriptive statistics. Pearson Correlation Coefficient, t-test, ANOVA and Stepwised Multiple Regression. The stress perception and reaction rates were low in cancer patients comparing to patients of the other study. In the coping patterns. the problem-focused coping patterns were significantly higher than emotion-focused coping patterns. The statistically meaningful differences were observed in the stress perception and reactions depending on the time of diagnosis and perceived health level. As for the problem-focused coping patterns, significant differences were found depending on age, marital status, education, income and the number of family members as well as perceived health level of patients. The level of perceived stress and that of stress reactions was found to have positively significant correlation(r=.764, p<.001) while the perceived stress and the problem-focused coping patterns was correlated negatively (r=-.288, p<.01). The stress reactions and the problem-focused coping patterns was found to have negatively significant correlation(r=-.289, p<.01). The problem-focused coping behavior, which cooperated with doctors, technologists, nurses and families of cancer patients, is advisable for the cancer patients to overcome uncertainty and uneasiness by effectively release the stress.

  15. Radiographic evaluation of maxillofacial fractures

    International Nuclear Information System (INIS)

    Litwan, M.; Fliegel, C.

    1986-01-01

    The course and configuration of typical maxillofacial fractures (type Le Fort I-III) and lateral maxillary fractures including the zygomatic arch were reconstructed in detail by application of barium paste on a bony skull and radiogrpahs in standard projections were performed and evaluated. It was obvious from the resulting radiographs that for most maxillofacial fractures a half axial or Water's view was most helpful. Lateral views only give additional information when there is a considerable degree of dislocation of fragments. Comparison with a prediatric skull of 8 years of age demonstrated that fractures of the zygomatic arch in this age group cannot be demonstrated by the typical submento-vertical view, but are shown on a Towne projection. The radiographic appearance of important maxillofacial fractures is demonstrated. The necessity of further studies in cases where reconstructive surgery appears necessary is discussed and CT rather then conventional tomography is advocated. (orig.) [de

  16. Retention of anatomy knowledge by student radiographers

    International Nuclear Information System (INIS)

    Hall, A. Susanne; Durward, Brian R.

    2009-01-01

    Introduction: Anatomy has long been regarded as an integral part of the core curriculum. However, anecdotal evidence suggests that long-term retention of anatomy knowledge may be deficient. This study aims to evidence whether student radiographers demonstrate the same level of knowledge of anatomy after a period of time has elapsed and to correlate to approaches to learning and studying. Methodology: A repeated measures design was utilised to measure retention of anatomy knowledge for both MCQs and short-response answers to a Practical Radiographic Anatomy Examination; alpha value p < 0.05. Fifty-one students from levels 2 and 3 were retested after a time lapse of 10 and 22 months respectively. The students were not aware that their knowledge was being retested. Approaches to learning and studying were measured using the ASSIST inventory. Results: Statistical analysis found no difference in performance on MCQ assessment, in either the combined sample or levels 2 and 3 separately, from baseline to retention occasions; average retention rate being 99%. However, a statistical difference in performance on PRAE assessment was found, with level 2 experiencing a larger reduction in scores; retention rate of 67% compared to level 3 at 77%. The students perceived themselves to be principally strategic in their approach to learning and studying but no strong relationships were found when correlated to test scores. Conclusion: The student radiographers in this study demonstrated varied anatomy retention rates dependent on assessment method employed and time interval that had elapsed. It is recommended that diverse teaching and assessment strategies are adopted to encourage a deeper approach to learning and studying.

  17. Image quality in digital radiographic systems

    Directory of Open Access Journals (Sweden)

    Almeida Solange Maria de

    2003-01-01

    Full Text Available The aim of the present study was to evaluate the image quality of four direct digital radiographic systems. Radiographs were made of the maxillary central incisor and mandibular left molar regions of a dry skull, and an aluminum step-wedge. The X-ray generator operated at 10 mA, 60 and 70 kVp, and images were acquired with 3, 5, 8, 12, 24 and 48 exposure pulses. Six well-trained observers classified the images by means of scores from 1 to 3. Collected data were submitted to nonparametric statistical analysis using Fisher's exact test. Statistical analysis showed significant differences (p<0.01 in image quality with the four systems. Based on the results, it was possible to conclude that: 1 all of the digital systems presented good performance in producing acceptable images for diagnosis, if the exposures of the step-wedge and the maxillary central incisor region were made at 5 pulses, as well as at 8 pulses for the mandibular left molar region, selecting 60 or 70kVp; 2 higher percentages of acceptable images were obtained with the administration of lower radiation doses in CCD-sensors (charge-coupled device; 3 the Storage Phosphor systems produced acceptable images at a large range of exposure settings, that included low, intermediate and high radiation doses.

  18. Pulmonary edema: radiographic differential diagnosis

    International Nuclear Information System (INIS)

    Yoo, Dong Soo; Choi, Young Hi; Kim, Seung Cheol; An, Ji Hyun; Lee, Jee Young; Park, Hee Hong

    1997-01-01

    To evaluate the feasibility of using chest radiography to differentiate between three different etiologies of pulmonary edema. Plain chest radiographs of 77 patients, who were clinically confirmed as having pulmonary edema, were retrospectively reviewed. The patients were classified into three groups : group 1 (cardiogenic edema : n = 35), group 2 (renal pulmonary edema : n = 16) and group 3 (permeability edema : n = 26). We analyzed the radiologic findings of air bronchogram, heart size, peribronchial cuffing, septal line, pleural effusion, vascular pedicle width, pulmonary blood flow distribution and distribution of pulmonary edema. In a search for radiologic findings which would help in the differentiation of these three etiologies, each finding was assessed. Cardiogenic and renal pulmonary edema showed overlapping radiologic findings, except for pulmonary blood flow distribution. In cardiogenic pulmonary edema (n=35), cardiomegaly (n=29), peribronchial cuffing (n=29), inverted pulmonary blood flow distribution (n=21) and basal distribution of edema (n=20) were common. In renal pulmonary edema (n=16), cardiomegaly (n=15), balanced blood flow distribution (n=12), and central (n=9) or basal distribution of edema (n=7) were common. Permeability edema (n=26) showed different findings. Air bronchogram (n=25), normal blood flow distribution (n=14) and peripheral distribution of edema (n=21) were frequent findings, while cardiomegaly (n=7), peribronchial cuffing (n=7) and septal line (n=5) were observed in only a few cases. On plain chest radiograph, permeability edema can be differentiated from cardiogenic or renal pulmonary edema. The radiographic findings which most reliably differentiated these two etiologies were air bronchogram, distribution of pulmonary edema, peribronchial cuffing and heart size. Only blood flow distribution was useful for radiographic differentiation of cardiogenic and renal edema

  19. The stress analysis evaluation and pipe support layout for pressurizer discharge system

    International Nuclear Information System (INIS)

    Mao Qing; Wang Wei; Zhang Yixiong

    2000-01-01

    The author presents the stress analysis and evaluation of pipe layout and support adjustment process for Qinshan phase II pressurizer discharge system. Using PDL-SYSPIPE INTERFACE software, the characteristic parameters of the system are gained from 3-D CAD engineering design software PDL and outputted as the input date file format of special pipe stress analysis program SYSPIPE. Based on that, SYSPIPE program fast stress analysis function is applied in adjusting pipe layout , support layout and support types. According to RCC-M standard, the pipe stress analysis and evaluation under deadweight, internal pressure, thermal expansion, seismic, pipe rupture and discharge loads are fulfilled

  20. Stress analysis of steam generator row-1 tubes

    International Nuclear Information System (INIS)

    Kim, Woo Gon; Ryu, Woo Seog; Lee, Ho Jin; Kim, Sung Chung

    2000-01-01

    Residual stresses induced in U-bending and tube-to-tubesheet joining processes of PWR's steam generator row-1 tube were measured by X-ray method and Hole-Drilling Method(HDM). The stresses resulting from the internal pressure and the temperature gradient in the steam generator were also estimated theoretically. In U-bent regions, the residual stresses at extrados were induced with compressive stress(-), and its maximum value reached -319 Mpa in axial direction at ψ=0 .deg. in position. Maximum tensile residual stress of 170 MPa was found to be at the flank side at position of ψ=90 deg., i.e., at apex region. In tube-to-tubesheet joining methods, the residual stresses induced by the explosive joint method were found to be lower than that by the mechanical roll method. The gradient of residual stress along the expanded tube was highest at the transition region, and the residual stress in circumferential direction was found to be higher than the residual stress in axial direction. Hoop stress due to an internal pressure between primary and secondary side was analyzed to be 76 MPa and thermal stress was 45 MPa

  1. Observer POD for radiographic testing

    Energy Technology Data Exchange (ETDEWEB)

    Kanzler, Daniel; Mueller, Christina; Bertovic, Marija [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany); Pitkaenen, Jorma [Posiva Oy, Eurajoki (Finland)

    2013-07-01

    The radiographic testing is an important non-destructive testing method, especially in industrial areas where people could be injured in case of failing of a component. There it is a mighty method to find volumetric defects. As bigger the penetrated length of the defect in the component is, as bigger is the radiographic contrast. The detectability of volumetric defects in its turn is not only depending on the contrast but also on the noise, the defect area and its shape. The currently applied POD approach uses mostly only the contrast and the noise as detection threshold. This does not reflect accurately the results of evaluations by human observers. A new approach is introduced, using the widely applied POD evaluation and additionally a detection threshold depending on the area of the defect. The presentation shows the process of calculating the POD curves with simulated data by the modeling software aRTist and with artificial reference data. This approach was developed within a joint project with the company POSIVA, which is constructing a final depository for high active nuclear fuels in Finland. Radiographic testing is one of the NDT-methods they use to test the electron beam welds of the copper canisters. The copper canisters will be used in the depository as a corrosion barrier within the waste management concept. (Published as a poster session.)

  2. Automating the radiographic NDT process

    International Nuclear Information System (INIS)

    Aman, J.K.

    1986-01-01

    Automation, the removal of the human element in inspection, has not been generally applied to film radiographic NDT. The justication for automating is not only productivity but also reliability of results. Film remains in the automated system of the future because of its extremely high image content, approximately 8 x 10 9 bits per 14 x 17. The equivalent to 2200 computer floppy discs. Parts handling systems and robotics applied for manufacturing and some NDT modalities, should now be applied to film radiographic NDT systems. Automatic film handling can be achieved with the daylight NDT film handling system. Automatic film processing is becoming the standard in industry and can be coupled to the daylight system. Robots offer the opportunity to automate fully the exposure step. Finally, computer aided interpretation appears on the horizon. A unit which laser scans a 14 x 17 (inch) film in 6 - 8 seconds can digitize film information for further manipulation and possible automatic interrogations (computer aided interpretation). The system called FDRS (for Film Digital Radiography System) is moving toward 50 micron (*approx* 16 lines/mm) resolution. This is believed to meet the need of the majority of image content needs. We expect the automated system to appear first in parts (modules) as certain operations are automated. The future will see it all come together in an automated film radiographic NDT system (author) [pt

  3. A Radiographic Study of Odontoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Ho; Choi, Karp Shik [Dept. of Dental Radiology, College of Dentistry, Kyungpook National University, Daegu (Korea, Republic of)

    1998-02-15

    The purpose of this study was to obtain information on the clinical and radiographic features of the odontomas in the jaws. For this study, the authors examined and analyzed the clinical records and radiographs of 119 patients who had lesion of odontoma diagnosed by clinical and radiographic examinations. The obtained results were as follows: 1. Odontoma occurred the most frequently in the 2nd decade (45.4%) and occurred more frequently in males (60.5%) than in females (39.5%). 2. The most common clinical symptom was the delayed eruption of the teeth (34.2%). 3. The type of lesions was mainly observed as compound odontoma (80.8%), and internal pattern of the complex odontoma was unevenly radiopaque (73.9%). 4. The compound odontoma frequently occurred in anterior portion of the maxilla (57.7%) and mandible (30.9%), and complex odontoma frequently occurred in anterior portion of maxilla (34.8%) and posterior portion of mandible (30.5%). 5. The effects on adjacent teeth were impaction of teeth (71.7%) and prolonged retention of deciduous teeth (31.7%). 6. The impaction of the teeth occurred in anterior portion of maxilla (44.2%) amd mandible (19.2%), but root resorption of the adjacent teeth were not seen. 7. The boundary to adjacent structure was well-defined , the lesions appear as radiopaque mass with radiolucent rim.

  4. Cervical spine motion: radiographic study

    International Nuclear Information System (INIS)

    Morgan, J.P.; Miyabayashi, T.; Choy, S.

    1986-01-01

    Knowledge of the acceptable range of motion of the cervical spine of the dog is used in the radiographic diagnosis of both developmental and degenerative diseases. A series of radiographs of mature Beagle dogs was used to identify motion within sagittal and transverse planes. Positioning of the dog's head and neck was standardized, using a restraining board, and mimicked those thought to be of value in diagnostic radiology. The range of motion was greatest between C2 and C5. Reports of severe disk degeneration in the cervical spine of the Beagle describe the most severely involved disks to be C4 through C7. Thus, a high range of motion between vertebral segments does not seem to be the cause for the severe degenerative disk disease. Dorsoventral slippage between vertebral segments was seen, but was not accurately measured. Wedging of disks was clearly identified. At the atlantoaxio-occipital region, there was a high degree of motion within the sagittal plane at the atlantoaxial and atlanto-occipital joints; the measurement can be a guideline in the radiographic diagnosis of instability due to developmental anomalies in this region. Lateral motion within the transverse plane was detected at the 2 joints; however, motion was minimal, and the measurements seemed to be less accurate because of rotation of the cervical spine. Height of the vertebral canal was consistently noted to be greater at the caudal orifice, giving some warning to the possibility of overdiagnosis in suspected instances of cervical spondylopathy

  5. Stress

    DEFF Research Database (Denmark)

    Keller, Hanne Dauer

    2015-01-01

    Kapitlet handler om stress som følelse, og det trækker primært på de få kvalitative undersøgelser, der er lavet af stressforløb.......Kapitlet handler om stress som følelse, og det trækker primært på de få kvalitative undersøgelser, der er lavet af stressforløb....

  6. Stress !!!

    OpenAIRE

    Fledderus, M.

    2012-01-01

    Twee op de vijf UT-studenten hebben last van ernstige studiestress, zo erg zelfs dat het ze in hun privéleven belemmert. Die cijfers komen overeen met het landelijk beeld van stress onder studenten. Samen met 14 andere universiteits- en hogeschoolbladen enquêteerde UT Nieuws bijna 5500 studenten. Opvallend is dat mannelijke studenten uit Twente zich veel minder druk lijken te maken over hun studie. Onder vrouwen ligt de stress juist erg hoog ten opzichte van het landelijk gemiddelde.

  7. Stress analysis and deformation prediction of sheet metal workpieces based on finite element simulation

    OpenAIRE

    Ren Penghao; Wang Aimin; Wang Xiaolong; Zhang Yanlin

    2017-01-01

    After aluminum alloy sheet metal parts machining, the residual stress release will cause a large deformation. To solve this problem, this paper takes a aluminum alloy sheet aerospace workpiece as an example, establishes the theoretical model of elastic deformation and the finite element model, and places quantitative initial stress in each element of machining area, analyses stress release simulation and deformation. Through different initial stress release simulative analysis of deformation ...

  8. Meditation for posttraumatic stress: Systematic review and meta-analysis.

    Science.gov (United States)

    Hilton, Lara; Maher, Alicia Ruelaz; Colaiaco, Benjamin; Apaydin, Eric; Sorbero, Melony E; Booth, Marika; Shanman, Roberta M; Hempel, Susanne

    2017-07-01

    We conducted a systematic review and meta-analysis that synthesized evidence from randomized controlled trials of meditation interventions to provide estimates of their efficacy and safety in treating adults diagnosed with posttraumatic stress disorder (PTSD). This review was based on an established protocol (PROSPERO: CRD42015025782) and is reported according to PRISMA guidelines. Outcomes of interest included PTSD symptoms, depression, anxiety, health-related quality of life, functional status, and adverse events. Meta-analyses were conducted using the Hartung-Knapp-Sidik-Jonkman method for random-effects models. Quality of evidence was assessed using the Grade of Recommendations Assessment, Development, and Evaluation (GRADE) approach. In total, 10 trials on meditation interventions for PTSD with 643 participants met inclusion criteria. Across interventions, adjunctive meditation interventions of mindfulness-based stress reduction, yoga, and the mantram repetition program improve PTSD and depression symptoms compared with control groups, but the findings are based on low and moderate quality of evidence. Effects were positive but not statistically significant for quality of life and anxiety, and no studies addressed functional status. The variety of meditation intervention types, the short follow-up times, and the quality of studies limited analyses. No adverse events were reported in the included studies; only half of the studies reported on safety. Meditation appears to be effective for PTSD and depression symptoms, but in order to increase confidence in findings, more high-quality studies are needed on meditation as adjunctive treatment with PTSD-diagnosed participant samples large enough to detect statistical differences in outcomes. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  9. Stress analysis of piping systems and piping supports. Documentation

    International Nuclear Information System (INIS)

    Rusitschka, Erwin

    1999-01-01

    The presentation is focused on the Computer Aided Tools and Methods used by Siemens/KWU in the engineering activities for Nuclear Power Plant Design and Service. In the multi-disciplinary environment, KWU has developed specific tools to support As-Built Documentation as well as Service Activities. A special application based on Close Range Photogrammetry (PHOCAS) has been developed to support revamp planning even in a high level radiation environment. It comprises three completely inter-compatible expansion modules - Photo Catalog, Photo Database and 3D-Model - to generate objects which offer progressively more utilization and analysis options. To support the outage planning of NPP/CAD-based tools have been developed. The presentation gives also an overview of the broad range of skills and references in: Plant Layout and Design using 3D-CAD-Tools; evaluation of Earthquake Safety (Seismic Screening); Revamps in Existing Plants; Inter-disciplinary coordination of project engineering and execution fields; Consulting and Assistance; Conceptual Studies; Stress Analysis of Piping Systems and Piping Supports; Documentation; Training and Supports in CAD-Design, etc. All activities are performed to the greatest extent possible using proven data-processing tools. (author)

  10. Chest radiographic manifestations of scrub typhus

    Directory of Open Access Journals (Sweden)

    KPP Abhilash

    2016-01-01

    Full Text Available Background and Rationale: Respiratory system involvement in scrub typhus is seen in 20–72% of patients. In endemic areas, good understanding and familiarity with the various radiologic findings of scrub typhus are essential in identifying pulmonary complications. Materials and Methods: Patients admitted to a tertiary care center with scrub typhus between October 2012 and September 2013 and had a chest X ray done were included in the analysis. Details and radiographic findings were noted and factors associated with abnormal X-rays were analyzed. Results: The study cohort contained 398 patients. Common presenting complaints included fever (100%, generalized myalgia (83%, headache (65%, dyspnea (54%, cough (24.3%, and altered sensorium (14%. Almost half of the patients (49.4% had normal chest radiographs. Common radiological pulmonary abnormalities included pleural effusion (14.6%, acute respiratory distress syndrome (14%, airspace opacity (10.5%, reticulonodular opacities (10.3%, peribronchial thickening (5.8%, and pulmonary edema (2%. Cardiomegaly was noted in 3.5% of patients. Breathlessness, presence of an eschar, platelet counts of 2 mg/dL had the highest odds of having an abnormal chest radiograph. Patients with an abnormal chest X-ray had a higher requirement of noninvasive ventilation (odds ratio [OR]: 13.98; 95% confidence interval CI: 5.89–33.16, invasive ventilation (OR: 18.07; 95% CI: 6.42–50.88, inotropes (OR: 8.76; 95% CI: 4.35–17.62, higher involvement of other organ systems, longer duration of hospital stay (3.18 ± 3 vs. 7.27 ± 5.58 days; P< 0.001, and higher mortality (OR: 4.63; 95% CI: 1.54–13.85. Conclusion: Almost half of the patients with scrub typhus have abnormal chest radiographs. Chest radiography should be included as part of basic evaluation at presentation in patients with scrub typhus, especially in those with breathlessness, eschar, jaundice, and severe thrombocytopenia.

  11. Patient-specific AAA wall stress analysis: 99-percentile versus peak stress

    NARCIS (Netherlands)

    Speelman, L.; Bosboom, E.M.H.; Schurink, G.W.H.; Hellenthal, F.A.M.V.I.; Buth, J.; Breeuwer, M.; Jacobs, M.J.; Vosse, van de F.N.

    2008-01-01

    Objective Biomechanically, rupture of an Abdominal Aortic Aneurysm (AAA) occurs when the stress acting on the wall due to the blood pressure, exceeds the strength of the wall. Peak wall stress estimations, based on CT reconstruction, may be prone to observer variation. This study focuses on the

  12. Linear Structural Stress Analysis of a Hull Girder Penetration and a Short Longitudinal Bulkhead Using Finite Element Modeling

    National Research Council Canada - National Science Library

    Baumann, Gregg

    1997-01-01

    ... (Integrated Design Engineering Analysis Software) software. The term 'shadow zone' refers to areas of low stress concentrations that are caused by lines of stress bending around structural discontinuities...

  13. Digital image processing of mandibular trabeculae on radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Ogino, Toshi

    1987-06-01

    The present study was aimed to reveal the texture patterns of the radiographs of the mandibular trabeculae by digital image processing. The 32 cases of normal subjects and the 13 cases of patients with mandibular diseases of ameloblastoma, primordial cysts, squamous cell carcinoma and odontoma were analyzed by their intra-oral radiographs in the right premolar regions. The radiograms were digitized by the use of a drum scanner densitometry method. The input radiographic images were processed by a histogram equalization method. The result are as follows : First, the histogram equalization method enhances the image contrast of the textures. Second, the output images of the textures for normal mandible-trabeculae radiograms are of network pattern in nature. Third, the output images for the patients are characterized by the non-network pattern and replaced by the patterns of the fabric texture, intertwined plants (karakusa-pattern), scattered small masses and amorphous texture. Thus, these results indicates that the present digital image system is expected to be useful for revealing the texture patterns of the radiographs and in the future for the texture analysis of the clinical radiographs to obtain quantitative diagnostic findings.

  14. Presence of bias in radiographer plain film reading performance studies

    International Nuclear Information System (INIS)

    Brealey, S.; Scally, A.J.; Thomas, N.B.

    2002-01-01

    Purpose To raise awareness of the frequency of bias that can affect the quality of radiographer plain film reading performance studies. Methods Studies that assessed radiographer(s) plain film reading performance were located by searching electronic databases and grey literature, hand-searching journals, personal communication and scanning reference lists. Thirty studies were judged eligible from all data sources. Results A one-way analysis of variance (ANOVA) demonstrates no statistically significant difference (P=0.25) in the mean proportion of biases present from diagnostic accuracy (0.37), performance (0.42) and outcome (0.44) study designs. Pearson's correlation coefficient showed no statistically significant linear association between the proportion of biases present for the three different study designs and the year that the study was performed. The frequency of biases in film and observer selection and application of the reference standard was quite low. In contrast, many biases were present concerning independence of film reporting and comparison of reports for concordance. Conclusions The findings indicate variation in the presence of bias in radiographer plain film reading performance studies. The careful consideration of bias is an essential component of study quality and hence the validity of the evidence-base used to underpin radiographic reporting policy

  15. Acute and Chronic Posttraumatic Stress Symptoms in the Emergence of Posttraumatic Stress Disorder: A Network Analysis.

    Science.gov (United States)

    Bryant, Richard A; Creamer, Mark; O'Donnell, Meaghan; Forbes, David; McFarlane, Alexander C; Silove, Derrick; Hadzi-Pavlovic, Dusan

    2017-02-01

    Little is understood about how the symptoms of posttraumatic stress develop over time into the syndrome of posttraumatic stress disorder (PTSD). To use a network analysis approach to identify the nature of the association between PTSD symptoms in the acute phase after trauma and the chronic phase. A prospective cohort study enrolled 1138 patients recently admitted with traumatic injury to 1 of 4 major trauma hospitals across Australia from March 13, 2004, to February 26, 2006. Participants underwent assessment during hospital admission (n = 1388) and at 12 months after injury (n = 852). Networks of symptom associations were analyzed in the acute and chronic phases using partial correlations, relative importance estimates, and centrality measures of each symptom in terms of its association strengths, closeness to other symptoms, and importance in connecting other symptoms to each other. Data were analyzed from March 3 to September 5, 2016. Severity of PTSD was assessed at each assessment with the Clinician-Administered PTSD Scale. Of the 1138 patients undergoing assessment at admission (837 men [73.6%] and 301 women [26.4%]; mean [SD] age, 37.90 [13.62] years), strong connections were found in the acute phase. Reexperiencing symptoms were central to other symptoms in the acute phase, with intrusions and physiological reactivity among the most central symptoms in the networks in terms of the extent to which they occur between other symptoms (mean [SD], 1.2 [0.7] and 1.0 [0.9], respectively), closeness to other symptoms (mean [SD], 0.9 [0.3] and 1.1 [0.9], respectively), and strength of the associations (mean [SD], 1.6 [0.3] and 1.5 [0.3] respectively) among flashbacks, intrusions, and avoidance of thoughts, with moderately strong connections between intrusions and nightmares, being upset by reminders, and physiological reactivity. Intrusions and physiological reactivity were central in the acute phase. Among the 852 patients (73.6%) who completed the 12-month

  16. Latinos, acculturation, and acculturative stress: a dimensional concept analysis.

    Science.gov (United States)

    Caplan, Susan

    2007-05-01

    Acculturation can be conceived of as a process of adaptation to stressful changes. In the field of public health, research indicates that recently arrived Latino immigrants, presumably most affected by acculturative stress, have better health outcomes than those who have spent greater time in the United States. This "immigrant paradox" is not well understood but supports the distinction between the process of acculturation and acculturative stress. To understand the nature of acculturative stress for Latinos in the context of political, historical, and societal forces. Acculturative stress significantly affects the physical and mental health of many Latino immigrants. Types of stressors vary by ethnicity. Separation from family and lack of a community was the most often-cited stressor for new immigrants. Most Latino immigrants were adversely affected by discrimination. By developing an understanding of acculturative stress, nurses can better attend to the needs of our increasingly diverse population.

  17. Proteomic analysis of soybean hypocotyl during recovery after flooding stress.

    Science.gov (United States)

    Khan, Mudassar Nawaz; Sakata, Katsumi; Komatsu, Setsuko

    2015-05-21

    Soybean is a nutritionally important crop, but exhibits reduced growth and yields under flooding stress. To investigate soybean responses during post-flooding recovery, a gel-free proteomic technique was used to examine the protein profile in the hypocotyl. Two-day-old soybeans were flooded for 2 days and hypocotyl was collected under flooding and during the post-flooding recovery period. A total of 498 and 70 proteins were significantly changed in control and post-flooding recovering soybeans, respectively. Based on proteomic and clustering analyses, three proteins were selected for mRNA expression and enzyme activity assays. Pyruvate kinase was increased under flooding, but gradually decreased during post-flooding recovery period at protein abundance, mRNA, and enzyme activity levels. Nucleotidylyl transferase was decreased under flooding and increased during post-flooding recovery at both mRNA expression and enzyme activity levels. Beta-ketoacyl reductase 1 was increased under flooding and decreased during recovery at protein abundance and mRNA expression levels, but its enzyme activity gradually increased during the post-flooding recovery period. These results suggest that pyruvate kinase, nucleotidylyl transferase, and beta-ketoacyl reductase play key roles in post-flooding recovery in soybean hypocotyl by promoting glycolysis for the generation of ATP and regulation of secondary metabolic pathways. This study analyzed post-flooding recovery response mechanisms in soybean hypocotyl, which is a model organ for studying secondary growth, using a gel-free proteomic technique. Mass spectrometry analysis of proteins extracted from soybean hypocotyls identified 20 common proteins between control and flooding-stressed soybeans that changed significantly in abundance over time. The hypocotyl proteins that changed during post-flooding recovery were assigned to protein, development, secondary metabolism, and glycolysis categories. The analysis revealed that three

  18. Temperature and Thermal Stress Analysis of Refractory Products

    Directory of Open Access Journals (Sweden)

    Shaoyang Shi

    2013-05-01

    Full Text Available Firstly current status of temperature and thermal stress research of refractory product at home and aboard are analyzed. Finite element model of two classical refractory products is building by using APDL language. Distribution law of temperature and thermal stress of two typical refractory products-ladles and tundish are analyzed and their structures are optimized. Stress of optimal structure is dropped obviously, and operation life is increased effectively.

  19. Radiographic appearances in Crohn's disease. I. Accuracy of radiographic methods

    Energy Technology Data Exchange (ETDEWEB)

    Hildell, J; Lindstroem, C; Wenckert, A [Departments of Diagnostic Radiology, Pathology and Surgery, Malmoe Allmaenna Sjukhus, Malmoe, Sweden

    1979-01-01

    Preoperative films of 176 patients operated upon for Crohn's disease were reviewed and compared with microscopic findings in the resected specimens in order to assess the accuracy of the radiographic techniques used. It was found that a diagnosis of the presence and the extent of the disease was often dependent on the demonstration of minor mucosal ulcers and less marked submucosal edema. These lesions were not adequately demonstrated by any of the techniques used for small bowel examination, but were consistently revealed by the double-contrast technique used for examination of the colon.

  20. Texture, residual stress and structural analysis of thin films using a combined X-ray analysis

    International Nuclear Information System (INIS)

    Lutterotti, L.; Chateigner, D.; Ferrari, S.; Ricote, J.

    2004-01-01

    Advanced thin films for today's industrial and research needs require highly specialized methodologies for a successful quantitative characterization. In particular, in the case of multilayer and/or unknown phases a global approach is necessary to obtain some or all the required information. A full approach has been developed integrating novel texture and residual stress methodologies with the Rietveld method (Acta Cryst. 22 (1967) 151) (for crystal structure analysis) and it has been coupled with the reflectivity analysis. The complete analysis can be done at once and offers several benefits: the thicknesses obtained from reflectivity can be used to correct the diffraction spectra, the phase analysis help to identify the layers and to determine the electron density profile for reflectivity; quantitative texture is needed for quantitative phase and residual stress analyses; crystal structure determination benefits of the previous. To achieve this result, it was necessary to develop some new methods, especially for texture and residual stresses. So it was possible to integrate them in the Rietveld, full profile fitting of the patterns. The measurement of these spectra required a special reflectometer/diffractometer that combines a thin parallel beam (for reflectivity) and a texture/stress goniometer with a curved large position sensitive detector. This new diffraction/reflectivity X-ray machine has been used to test the combined approach. Several spectra and the reflectivity patterns have been collected at different tilting angles and processed at once by the special software incorporating the aforementioned methodologies. Some analysis examples will be given to show the possibilities offered by the method