WorldWideScience

Sample records for stress radiographic analysis

  1. Development of a micrometre-scale radiographic measuring method for residual stress analysis

    International Nuclear Information System (INIS)

    Moeller, D.

    1999-01-01

    The radiographic method described uses micrometre X-ray diffraction for high-resolution residual stress analysis in single crystals. The focus is on application of two x-ray optics (glass capillaries) for shaping a sufficiently fine and intensive primary beam. Due to application of a proper one-grain measuring and analysis method, the resolution results are applicable to the characteristic grain sizes of many materials. (orig.) [de

  2. Occupational stress among radiographers: the impact of sonagraphy ...

    African Journals Online (AJOL)

    Sonography responsibility on radiographers did not have any significant effect on psychosocial stress. A balance in the extended role could aid efficiency in service delivery while improving the social strength of the individual. Keywords: Occupational stress; radiographers; sonographers. Internet Journal of Medical Update ...

  3. Effects of occupational stress and coping mechanisms adopted by radiographers in Ghana

    International Nuclear Information System (INIS)

    Ashong, G.G.N.A.; Rogers, H.; Botwe, B.O.; Anim-Sampong, S.

    2016-01-01

    Background: Studies have shown that population of radiography staff within various hospitals in Ghana decreased by 30% in the last decade due to several reasons. One of such reasons understood to be related to stress and job satisfaction which affect work output. Purpose: To investigate the effects of occupational stress and the coping mechanisms adopted by radiographers in Ghana. Method: A descriptive survey using a five-point Likert-scale questionnaire with pre-coded responses was administered via email to respondents. Purposive sampling method was used to select 190 radiographers who work in hospitals in Ghana. Descriptive statistics was mainly used to analyse the data using SPSS Version 20. Results: Of a total 190 questionnaires sent, 122 were completed and returned giving a 64.3% response rate. Majority 78 (64%) of respondents were males and the predominant area of work was conventional radiography. Most radiographers revealed they were stressed with 63% indicating high/very high levels of stress. The consequent effects of stress on radiographers were sick absence, depression and job dissatisfaction. Most of the radiographers used primary interventions to cope with stress. Conclusion: This study has demonstrated that most radiographers in Ghana are stressed. However, they cope well with problem-solving mechanisms. This suggests that the decrease in number of radiographers within various facilities in Ghana by 30% may not necessarily be caused by stress but other factors which need to be investigated. Nevertheless, occupational stress has an effect on radiographers' quality of working life and may directly impact on their behaviour during service delivery. - Highlights: • There is high level of occupational stress among Ghanaian Radiographers. • Some sources and causes of occupational stress among Ghanaian Radiographers were workload, poor pay and shortage of staff. • Job dissatisfaction, depression and sick absence were effects of occupational

  4. Relationship between stress ankle radiographs and injured ligaments on MRI

    International Nuclear Information System (INIS)

    Lee, Kyoung Min; Chung, Chin Youb; Chung, Myung Ki; Won, Sung Hun; Lee, Seung Yeol; Park, Moon Seok; Kwon, Soon-Sun

    2013-01-01

    This study was performed to investigate the relationship between the injured lateral ankle ligaments on MRI and stress ankle radiographs. Two hundred and twenty-nine consecutive patients (mean age 35.5 years, SD 14.6 years; 136 males and 93 females) that underwent ankle stress radiographs and MRI for lateral ankle instability were included. Tibiotalar tilt angle and anterior translation of talus were measured on stress ankle radiographs. Degree of lateral ligaments (anterior talofibular, calcaneofibular, and posterior talofibular) and deltoid ligament injuries were evaluated and scored as intact (0), partial injury (1), and complete injury (2) on MR images. Effusion of ankle joint was also recorded. The effects of gender, age, injuries of ligaments, and ankle joint effusion on stress radiographs were statistically analyzed. Gender (p = 0.010), age (p = 0.020), and anterior talofibular ligament (ATFL) injury (p < 0.001) were the factors significantly affecting tibiotalar tilt angle. Posterior talofibular ligament (PTFL) injury (p = 0.014) was found to be the only significant factor affecting the anterior translation on the anterior drawer radiographs. ATFL injury and PTFL injury on MRI significantly affected tibiotalar tilt angle and anterior drawer on stress radiographs. Other factors, such as age and gender, need to be considered in evaluating radiographic lateral ankle instability. (orig.)

  5. Radiographic evaluation of coxofemoral joint laxity in dogs part I: New stress-radiographic positioning techniques

    International Nuclear Information System (INIS)

    Phiwipha Kamonrat; Duangdaun Kaenkangploo

    2002-01-01

    Two new stress-radiographic positioning techniques, namely 60 deg and 90 deg stress techniques, were introduced for quantifying hip joint laxity in dogs. The comparative characteristics and efficiency of these new techniques with angled hindlimbs were evaluated relative to the standard hip-extended radiographic technique. Forty, healthy, mongrel dogs with normal hip joint conformation were anesthetized and placed in dorsal recumbency before 3 radiograhps of the standard, 60 deg , and 90 deg stress techniques were taken. For the 60 deg stress technique, hindlimbs were extended in parallel to each other at 60 deg angled to the table top and stifles were slightly rotated inward, femoral heads were manually pushed in a craniodorsal direction during exposure. For the 90 deg stress technique, femurs were positioned perpendicular to the table top, stifles were 90 deg flexed and adducted and femoral heads were manually pushed in a craniodorsal direction during exposure. The subluxation index (SI) and dorsolateral subluxation score (DLS score) were calculated from 3 radiographic views for both hip joints to quantitate the relative degree of joint laxity. Results of the study indicated that the 60 deg (SI = 0.20+-0.045, DLS score = 62.5+-7.96 percent) and 90 deg (SI = 0.23+-0.044, DLS score = 61.2+-9.47 percent) stress-radiographs yielded significantly (p0.001) higher degree of hip joint laxity than the standard technique (SI)

  6. Occupational stress and its predictors in radiographers

    Energy Technology Data Exchange (ETDEWEB)

    Rutter, D.R. [Centre for Research in Health Behaviour, Department of Psychology, University of Kent, Keynes College, Canterbury CT2 7NP (United Kingdom)], E-mail: d.r.rutter@kent.ac.uk; Lovegrove, M.J. [Department of Allied Health Professions, London South Bank University, London SE1 0AA (United Kingdom)

    2008-05-15

    Purpose: The purpose of this study was to establish the level of occupational stress in UK NHS radiographers, and to examine its causes. A total of more than 1600 radiographers sampled nationally completed a postal questionnaire. Four groups were represented - mammography, diagnostics, radiotherapy, and ultrasound - and both junior staff and superintendents were examined. Method: The questionnaire measured role ambiguity, role conflict, work problems, social support from colleagues, and perceived stress. Results: Levels of perceived stress were high in all four groups. The mean was significantly lower in the mammography group than the others, however, and junior staff reported lower levels than superintendents. Role ambiguity, role conflict and work problems all contributed significantly to stress, but the effects were sometimes buffered by social support from colleagues. Conclusion: The implications of the findings are discussed for theory and for policy and practice: occupational stress was predicted by intrinsic features of the job; the levels were similar to those reported by other NHS professionals; and the pattern of findings suggests possible ways to intervene to reduce it.

  7. Occupational stress and its predictors in radiographers

    International Nuclear Information System (INIS)

    Rutter, D.R.; Lovegrove, M.J.

    2008-01-01

    Purpose: The purpose of this study was to establish the level of occupational stress in UK NHS radiographers, and to examine its causes. A total of more than 1600 radiographers sampled nationally completed a postal questionnaire. Four groups were represented - mammography, diagnostics, radiotherapy, and ultrasound - and both junior staff and superintendents were examined. Method: The questionnaire measured role ambiguity, role conflict, work problems, social support from colleagues, and perceived stress. Results: Levels of perceived stress were high in all four groups. The mean was significantly lower in the mammography group than the others, however, and junior staff reported lower levels than superintendents. Role ambiguity, role conflict and work problems all contributed significantly to stress, but the effects were sometimes buffered by social support from colleagues. Conclusion: The implications of the findings are discussed for theory and for policy and practice: occupational stress was predicted by intrinsic features of the job; the levels were similar to those reported by other NHS professionals; and the pattern of findings suggests possible ways to intervene to reduce it

  8. Radiographic evaluation of coxofemoral joint laxity in dogs part II: Comparison of stress-radiographic positioning techniques in dogs with hip dysplasia

    International Nuclear Information System (INIS)

    Duangdaun Kaenkangploo; Phiwipha Kamonrat; Marissak Kalpravidh

    2002-01-01

    Two stress-radiographic positioning techniques for evaluation of coxofemoral joint laxity in dogs with hip dysplasia were compared with the standard technique. Forty, healthy, large breed dogs were divided into two groups of 20 dogs. Group 1 had normal hips. Group 2 were dogs with mild to moderated grade of hip dysplasia according to the Orthopedic Foundation for Animals (OFA) standard. Dogs were anesthetized and placed in dorsal recumbency before 3 radiographic techniques, standard hip-extended, 60 deg and 90 deg stress techniques, were taken. For the 60 deg stress technique, hind legs were extended in parallel to each other at 60 deg to the table top and femoral heads were manually pushed craniodorsally during exposure. For the 90 deg stress technique, femurs were positioned perpendicular to the table top, stifles were 90 deg flexed and adducted and femoral heads were manually pushed in a craniodorsal direction during exposure. Subluxation index (SI) and dorsolateral subluxation score (DLS score) of coxofemoral joints were assessed from radiographs. The SI of normal dogs from standard, 60 deg and 90 deg stress techniques were 0.15, 0.20 and 0.23 and of dysplastic dogs were 0.34, 0.40 and 0.41 respectively. The degress of subluxation assessed from the two stress technique radiographs were significantly greater (p0.05) than those shown on the standard technique radiographs in both groups of dogs. DLS scores of normal dogs from standard, 60 deg and 90 deg stress techniques were 65.1, 64.3 and 61.0 percent and of dysplastic dogs were 55.4, 53.6 and 47.6 percent respectively. Mean of DLS scores assessed from the 90 deg radiographs was significantly lower (p0.05) than those assessed from radiographs of other two teachniques in both groups of dogs. The findings suggested that the 90 deg stress technique is more efficient than the standard and 60 deg stress techniques for radiographic evaluation of coxofemoral joint laxity in dogs with mild hip dysplasia and early

  9. Significance of radiographic abnormalities in patients with tibial stress injuries: correlation with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kijowski, Richard; Choi, James; Smet, Arthur de; Mukharjee, Rajat

    2007-01-01

    The objective was to correlate radiographic findings with magnetic resonance imaging (MRI) findings in patients with suspected tibial stress injuries in order to determine the significance of radiographic signs of stress injury in these individuals. The study group consisted of 80 patients with suspected tibial stress injuries who underwent a radiographic and MR examination of the tibia. Nineteen patients had bilateral involvement. Thus, a total of 99 tibias were evaluated. All radiographs and MR examinations were retrospectively reviewed, 1 month apart, in consensus by two musculoskeletal radiologists. The radiographs were reviewed without knowledge of the site of the clinical symptoms. Fisher's exact tests were used to determine the association between a positive radiograph and the presence of various MRI signs of a high-grade stress injury. There was a strong association between the presence of periosteal reaction on radiographs at the site of the clinical symptoms and a Fredericson grade 4 stress injury on MRI. The presence of periosteal reaction on radiographs at the site of clinical symptoms is predictive of a high-grade stress injury by MRI criteria. (orig.)

  10. Stress radiographs in the evaluation of degenerative femorotibial joint disease

    Energy Technology Data Exchange (ETDEWEB)

    Tallroth, K.; Lindholm, T.S.

    1987-11-01

    Thirty-eight osteoarthrotic knees were examined to assess the widths of the femorotibial joint spaces. Radiographs were exposed with the patient lying, in a standing position, and with an adduction and abduction force. Forced compression of the osteoarthrotic joint compartment caused, on average, 18% greater narrowing than when loading it in the standing position. Compared to the joint space at rest, the non-weight-bearing compartment widened by 16% in the standing position and narrowed by 20% when stress was applied. Furthermore, the results showed an increase in laxity proportional to the degree of arthrosis. Stress radiographs significantly display the real cartilage width of both joint compartments. Knowledge of the condition of the articular cartilage in the non-weight-bearing compartment is important when considering a transfer of loading stresses by means of osteotomy. (orig.)

  11. Stress radiographs in the evaluation of degenerative femorotibial joint disease

    International Nuclear Information System (INIS)

    Tallroth, K.; Lindholm, T.S.

    1987-01-01

    Thirty-eight osteoarthrotic knees were examined to assess the widths of the femorotibial joint spaces. Radiographs were exposed with the patient lying, in a standing position, and with an adduction and abduction force. Forced compression of the osteoarthrotic joint compartment caused, on average, 18% greater narrowing than when loading it in the standing position. Compared to the joint space at rest, the non-weight-bearing compartment widened by 16% in the standing position and narrowed by 20% when stress was applied. Furthermore, the results showed an increase in laxity proportional to the degree of arthrosis. Stress radiographs significantly display the real cartilage width of both joint compartments. Knowledge of the condition of the articular cartilage in the non-weight-bearing compartment is important when considering a transfer of loading stresses by means of osteotomy. (orig.)

  12. Digital image analysis of NDT radiographs

    International Nuclear Information System (INIS)

    Graeme, W.A. Jr.; Eizember, A.C.; Douglass, J.

    1989-01-01

    Prior to the introduction of Charge Coupled Device (CCD) detectors the majority of image analysis performed on NDT radiographic images was done visually in the analog domain. While some film digitization was being performed, the process was often unable to capture all the usable information on the radiograph or was too time consuming. CCD technology now provides a method to digitize radiographic film images without losing the useful information captured in the original radiograph in a timely process. Incorporating that technology into a complete digital radiographic workstation allows analog radiographic information to be processed, providing additional information to the radiographer. Once in the digital domain, that data can be stored, and fused with radioscopic and other forms of digital data. The result is more productive analysis and management of radiographic inspection data. The principal function of the NDT Scan IV digital radiography system is the digitization, enhancement and storage of radiographic images

  13. Weightbearing vs Gravity Stress Radiographs for Stability Evaluation of Supination-External Rotation Fractures of the Ankle.

    Science.gov (United States)

    Seidel, Angela; Krause, Fabian; Weber, Martin

    2017-07-01

    Isolated lateral malleolar fractures may result from a supination-external rotation (SER) injury of the ankle. Stable fractures maintain tibiotalar congruence due to competent medial restraints and can be treated nonoperatively with excellent functional results and long-term prognosis. Stability might be assessed with either stress radiographs or weightbearing radiographs. A consecutive series of patients with closed SER fractures (presumed AO 44-B1) were prospectively enrolled from 2008 to 2015. Patients with clearly unstable fractures (medial clear space more than 7 mm) on the initial nonweightbearing radiograph were excluded and operated on. All other patients were examined with a gravity stress and a weightbearing anteroposterior radiograph. Borderline instability of the fracture was assumed when the medial clear space was 4 to 7 mm. Those were treated nonoperatively. Of 104 patients with isolated lateral malleolar fractures of the SER type, 14 patients were treated operatively because of clear instability (displacement) on the initial radiographs. Of the nonoperative patients, 44 patients demonstrated borderline instability on the gravity stress but stability on the weightbearing radiograph ("gravity borderline"); the remaining 46 were stable in both tests ("gravity stable"). At an average follow-up of 23 months, no significant differences were seen in the American Orthopaedic Foot & Ankle Society hindfoot score (92 points gravity-borderline group vs 93 points gravity-unstable group), the Foot Functional Index score (11 vs 10 points), the Short Form 36 (SF-36) physical component (86 vs 85 points), and SF-36 mental component (84 vs 81 points). Radiographically, all fractures had healed with anatomic congruity of the ankle. Weightbearing radiographs provided a reliable basis to decide about stability and nonoperative treatment in isolated lateral malleolar fractures of the SER type with excellent clinical and radiographic outcome at short-term follow-up. Gravity

  14. Methodological model of chronic stress associated with ligature-induced periodontitis in rats: a radiographic study

    Directory of Open Access Journals (Sweden)

    Alex Semenoff Segundo

    2010-12-01

    Full Text Available This study evaluated the time efficiency of stress associated with ligature-induced periodontitis in rats. Sixty adult Wistar rats, housed in temperature-controlled rooms and receiving water and food ad libitum, were randomly separated into stress (n = 30 or control groups (n = 30. All animals were anesthetized, and nylon ligatures were placed at the gingival margin level of the maxillary right second molars. After the induction of periodontitis, rats in the stress group were subjected to physical restraint for 12 hours daily. The animals were euthanized after 7, 15 and 30 days by anesthetic overdose (10 animals per group per period. The right hemimaxillae were stored in formalin solution for 48 hours. Parallel radiographic images of the hemimaxillae were taken and processed following standard procedures. Radiographic examination was performed by a blinded and previously calibrated investigator. Bone height level was measured, and data were submitted to analysis of variance and post hoc Bonferroni tests (p 0.05. Restraint stress modulates the short-term progression of periodontal disease in rats. Therefore, the 12-hour daily physical restraint stress model in rats applied for up to 15 days is suitable for the investigation of the combined effect of ligation and restraint stress on periodontal degradation.

  15. The prevalence and antecedents of occupational stress among radiographers in Zimbabwe: Interplay of economics and culture

    Directory of Open Access Journals (Sweden)

    Chingarande George R, Ndlovu Bekezela

    2013-04-01

    Full Text Available The purpose and objectives of this study were to find out the incidence of Occupational Stress amongst radiographers and also to find out the main stressors that they are exposed to. A cross sectional survey using both qualitative and quantitative methodologies and a questionnaire as a research tool was conducted. The questionnaire was given to all radiographers working in the general radiology department of the six departments/centres that participated in the study. The results revealed that there is a high incidence of occupational stress among medical radiographers working in general radiology. The results also showed that the most frequently encountered stressors in the general radiology department are pressure to complete tasks/overwork, inadequate salaries and inadequate holiday/vacation time. There were no significant differences in the incidences of occupational stress between male and female radiographers. However, there were differences in the perceptions of the two genders on the causes of stress. This was attributed to the cultural gender role expectations.

  16. Radiographic enhancement and analysis system

    International Nuclear Information System (INIS)

    Schlosser, M.S.

    1981-01-01

    Radiographic image enhancement and analysis techniques are discussed as they apply to nondestructive inspection. A system is described which has been developed to enhance and quantitatively evaluate radiographic images using digital computer techniques. Some examples of typical applications are also presented as an introduction to this new inspection technique. (author)

  17. Stress fractures of the humerus, radius, and tibia in horses: clinical features and radiographic and/or scintigraphic appearance

    International Nuclear Information System (INIS)

    Mackey, V.S.; Trout, D.R.; Meagher, D.M.; Hornof, W.J.

    1987-01-01

    The medical records, radiographic and nuclear scintigraphic findings of 26 racing horses with 27 stress fracture episodes of the humerus, radius, or tibia were reviewed. The purposes of this study were to describe the radiographic and/or scintigraphic features of stress fractures of the humerus, radius, or tibia, and to evaluate the signalment and history of horses in which stress fracture occurred. Stress fractures of the three long bones examined were primarily seen in 2- and 3-year-old male Thoroughbred horses; commonly, the onset of lameness was immediately following training gallops or racing. There were 13 humeral stress fracture episodes in 12 horses. Ten were in the proximal caudolateral cortex, and three were in the distal craniomedial cortex. Radical stress fractures were seen in three horses, all in the midshaft radius. Tibial stress fractures were diagnosed in 11 horses. They were located in the proximal lateral tibia in six horses, the distal caudolateral tibia in three horses, and the midshaft tibia in three horses. Fifteen stress fractures were diagnosed with radiography alone, one was diagnosed with scintigraphy alone, nine were diagnosed with radiographs and scintigraphy, and, in two horses, radiographs were negative, but the scintigraphic findings were consistent with stress fracture

  18. Post traumatic stress disorder and the forensic radiographer

    International Nuclear Information System (INIS)

    Glaysher, E.; Vallis, J.; Reeves, P.

    2016-01-01

    The term post traumatic stress disorder (PTSD) is used to describe the psychological issues resulting from any traumatic event. An individual's ability to function is impaired by experiencing emotional responses to a traumatic event. Forensic radiographers need to be aware of the potential debilitating effects of this condition and those writing forensic protocols must take the condition into account and build in safeguards and welfare strategies. This narrative review looks at the origins of the term PTSD and highlights those who may be at increased risk of developing the condition including, in particular, forensic radiographers involved in mass fatality work. Signs, symptoms and possible treatments are also reviewed. - Highlights: • Presents a summary of PTSD for those working in forensic radiography. • Outlines signs & symptoms of PTSD. • Discusses treatment & prognosis of PTSD. • Suggests ways of managing factors which may predispose to PTSD.

  19. Transfer function analysis of radiographic imaging systems

    International Nuclear Information System (INIS)

    Metz, C.E.; Doi, K.

    1979-01-01

    The theoretical and experimental aspects of the techniques of transfer function analysis used in radiographic imaging systems are reviewed. The mathematical principles of transfer function analysis are developed for linear, shift-invariant imaging systems, for the relation between object and image and for the image due to a sinusoidal plane wave object. The other basic mathematical principle discussed is 'Fourier analysis' and its application to an input function. Other aspects of transfer function analysis included are alternative expressions for the 'optical transfer function' of imaging systems and expressions are derived for both serial and parallel transfer image sub-systems. The applications of transfer function analysis to radiographic imaging systems are discussed in relation to the linearisation of the radiographic imaging system, the object, the geometrical unsharpness, the screen-film system unsharpness, other unsharpness effects and finally noise analysis. It is concluded that extensive theoretical, computer simulation and experimental studies have demonstrated that the techniques of transfer function analysis provide an accurate and reliable means for predicting and understanding the effects of various radiographic imaging system components in most practical diagnostic medical imaging situations. (U.K.)

  20. A study of trabecular bone strength and morphometric analysis of bone microstructure from digital radiographic image

    International Nuclear Information System (INIS)

    Han, Seung Yun; Lee, Sun Bok; Oh, Sung Ook; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul; Park, Tae Won; Kim, Jong Dae

    2003-01-01

    To evaluate the relationship between morphometric analysis of microstructure from digital radiographic image and trabecular bone strength. One hundred eleven bone specimens with 5 mm thickness were obtained from the mandibles of 5 pigs. Digital images of specimens were taken using a direct digital intraoral radiographic system. After selection of ROI(100 x 100 pixel) within the trabecular bone, mean gray level and standard deviation were obtained. Fractal dimension and the variants of morphometric analysis (trabecular area, periphery, length of skeletonized trabeculae, number of terminal point, number of branch point) were obtained from ROI. Punch sheer strength analysis was performed using Instron (model 4465, Instron Corp., USA). The loading force (loading speed 1mm/min) was applied to ROI of bone specimen by a 2 mm diameter punch. Stress-deformation curve was obtained from the punch sheer strength analysis and maximum stress, yield stress, Young's modulus were measured. Maximum stress had a negative linear correlation with mean gray level and fractal dimension significantly (p<0.05). Yield stress had a negative linear correlation with mean gray level, periphery, fractal dimension and the length of skeletonized trabeculae significantly (p<0.05). Young's modulus had a negative linear correlation with mean gray level and fractal dimension significantly (p<0.05). The strength of cancellous bone exhibited a significantly linear relationship between mean gray level, fractal dimension and morphometric analysis. The methods described above can be easily used to evaluate bone quality clinically.

  1. An investigation into work related stressors on diagnostic radiographers in a local district hospital

    International Nuclear Information System (INIS)

    Verrier, William; Harvey, Jane

    2010-01-01

    Extensive research on the effects of work related stress amongst healthcare professions and the NHS has been undertaken. However, very little is known about the incidence of stress amongst UK radiographers although the few studies which have been conducted indicate that the prevalence and impact of stress on radiographers are considerable. The purpose of this study was to examine work related stressors which affect diagnostic radiographers in the imaging department of a local district hospital. The study utilised the HSE Indicator and Analysis Tools for Work Related Stress. These tools are based upon the HSE Management Standards for Work Related Stress which identifies six areas that represent potential stress hazards if managed inadequately. Two free response questions and a comments box were appended to the Indicator Tool to gain further insights into the radiographers' experiences of work related stress. The results of the study indicated that the hazards associated with work related stress risk were not being optimally managed in the department. Areas of Managers' Support, Relationships, Role and Change represented the greatest risks. In addition, the radiographers cited staff shortages, heavy workload and volume of patients as the greatest sources of pressure at work and their most common recommendations to reduce stress at work were increased staffing, improved communication and more effective feedback systems.

  2. Dynamic Stress Testing Is Unnecessary for Unimalleolar Supination-External Rotation Ankle Fractures with Minimal Fracture Displacement on Lateral Radiographs.

    Science.gov (United States)

    Nortunen, Simo; Leskelä, Hannu-Ville; Haapasalo, Heidi; Flinkkilä, Tapio; Ohtonen, Pasi; Pakarinen, Harri

    2017-03-15

    This study aimed to identify factors from standard radiographs that contributed to the stability of the ankle mortise in patients with isolated supination-external rotation fractures of the lateral malleolus (OTA/AO 44-B). Non-stress radiographs of the mortise and lateral views, without medial clear space widening or incongruity, were prospectively collected for 286 consecutive patients (mean age, 45 years [range, 16 to 85 years]), including 144 female patients (mean age, 50 years [range, 17 to 85 years]) and 142 male patients (mean age, 40 years [range, 16 to 84 years]) from 2 trauma centers. The radiographs were analyzed for fracture morphology by 2 orthopaedic surgeons, who were blinded to each other's measurements and to the results of external rotation stress radiographs (the reference for stability). Factors significantly associated with ankle mortise stability were tested in multiple logistic regression. Receiver operating characteristic analyses were performed for continuous variables to determine optimal thresholds. A sensitivity of >90% was used as the criterion for an optimal threshold. According to external rotation stress radiographs, 217 patients (75.9%) had a stable injury, defined as that with a medial clear space of ankle mortise were female sex (odds ratio [OR], 2.5 [95% confidence interval (CI), 1.4 to 4.6]), a posterior diastasis of fracture fragments (OR, 7.3 [95% CI, 2.1 to 26.3]). When the posterior diastasis was fracture fragments were present, the probability of a stable ankle mortise was 0.98 for 48 female patients (16.8%) and 0.94 for 37 male patients (12.9%). Patients with noncomminuted lateral malleolar fractures (85 patients [29.7%]) could be diagnosed with a stable ankle mortise without further stress testing, when the fracture line widths were <2 mm on lateral radiographs. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  3. Image quality preferences among radiographers and radiologists. A conjoint analysis

    International Nuclear Information System (INIS)

    Ween, Borgny; Kristoffersen, Doris Tove; Hamilton, Glenys A.; Olsen, Dag Rune

    2005-01-01

    Purpose: The aim of this study was to investigate the image quality preferences among radiographers and radiologists. The radiographers' preferences are mainly related to technical parameters, whereas radiologists assess image quality based on diagnostic value. Methods: A conjoint analysis was undertaken to survey image quality preferences; the study included 37 respondents: 19 radiographers and 18 radiologists. Digital urograms were post-processed into 8 images with different properties of image quality for 3 different patients. The respondents were asked to rank the images according to their personally perceived subjective image quality. Results: Nearly half of the radiographers and radiologists were consistent in their ranking of the image characterised as 'very best image quality'. The analysis showed, moreover, that chosen filtration level and image intensity were responsible for 72% and 28% of the preferences, respectively. The corresponding figures for each of the two professions were 76% and 24% for the radiographers, and 68% and 32% for the radiologists. In addition, there were larger variations in image preferences among the radiologists, as compared to the radiographers. Conclusions: Radiographers revealed a more consistent preference than the radiologists with respect to image quality. There is a potential for image quality improvement by developing sets of image property criteria

  4. Radiographic and Clinical Analysis of Lateral Epicondylitis.

    Science.gov (United States)

    Shillito, Matthew; Soong, Maximillian; Martin, Nicholas

    2017-06-01

    The literature suggests that radiographs may be unnecessary in the initial evaluation of lateral epicondylitis because treatment is rarely altered as a result of the radiographic findings. The most commonly reported radiographic finding is calcification at the lateral epicondyle. Our goal was to perform a quantitative and qualitative analysis of this finding to determine its importance and possible relationship with various clinical factors and patient-reported measures. All patients diagnosed with lateral epicondylitis by a single surgeon during a 5-year period were retrospectively reviewed. Age, sex, laterality, hand dominance, pain visual analog scale, duration of symptoms, Quick-Disability of the Arm, Shoulder, and Hand questionnaire score, and history of steroid injection were recorded. Calcifications on standard elbow radiographs, acquired digitally and viewed at 200% magnification on a 24-inch monitor, were characterized by size and relationship with the lateral epicondyle. We reviewed 245 patients diagnosed with lateral epicondylitis. A total of 115 elbows (47%) demonstrated lateral epicondyle calcifications. Patients with and without calcifications were similar with regard to clinical factors, as were patients with larger or smaller lesions. Eighty-five elbows (35%) had additional radiographic findings. Treatment was not altered by the radiographic findings in any case. Lateral epicondyle calcifications are much more common in lateral epicondylitis than previously reported, possibly owing to modern digital radiography and magnification, although they do not appear to be related to clinical factors including patient-reported measures. Thus, patients and surgeons should be careful to avoid overinterpretation of such findings. Although radiographs may be helpful in ruling out additional pathology, we did not find other clinically important contributions to the initial evaluation and management of this condition, and thus we do not recommend their routine use

  5. Radiographic findings of degeneration in cervical spines of middle-aged soccer players

    International Nuclear Information System (INIS)

    Kurosawa, Hideki; Yamakoshi, Ken-ichi

    1991-01-01

    Twelve amateur veteran soccer players (average age 40.1 ± 5.4 years), who began playing in their teens and who were admitted with symptoms most likely to be related to cervical spondylosis, were examined by cervical radiography. Abnormal radiographic findings included: calcification of anterior longitudinal ligament (25%), anterior (75%) and posterior vertebral spurs (75%), ossicle between spinous processes (75%), calcification of nuchal ligament (Barsony) (58%), ossicle on spinous process (25%), and bony spur of Luschka's joints (83%). It was shown in the stress distribution by finite element method analysis that the stress in heading the ball was applied mainly to the lower parts of the cervical spine. The results of this analysis also corresponded well with some of the radiographic findings. (orig.)

  6. Radiographic findings of degeneration in cervical spines of middle-aged soccer players

    Energy Technology Data Exchange (ETDEWEB)

    Kurosawa, Hideki; Yamakoshi, Ken-ichi (Hokkaido Univ., Sapporo (Japan). Research Inst. of Applied Electricity); Yamanoi, Takahiro (Hokkaigakuen Univ., Sapporo (Japan))

    1991-08-01

    Twelve amateur veteran soccer players (average age 40.1 {+-} 5.4 years), who began playing in their teens and who were admitted with symptoms most likely to be related to cervical spondylosis, were examined by cervical radiography. Abnormal radiographic findings included: calcification of anterior longitudinal ligament (25%), anterior (75%) and posterior vertebral spurs (75%), ossicle between spinous processes (75%), calcification of nuchal ligament (Barsony) (58%), ossicle on spinous process (25%), and bony spur of Luschka's joints (83%). It was shown in the stress distribution by finite element method analysis that the stress in heading the ball was applied mainly to the lower parts of the cervical spine. The results of this analysis also corresponded well with some of the radiographic findings. (orig.).

  7. Radiograph and passive data analysis using mixed variable optimization

    Science.gov (United States)

    Temple, Brian A.; Armstrong, Jerawan C.; Buescher, Kevin L.; Favorite, Jeffrey A.

    2015-06-02

    Disclosed herein are representative embodiments of methods, apparatus, and systems for performing radiography analysis. For example, certain embodiments perform radiographic analysis using mixed variable computation techniques. One exemplary system comprises a radiation source, a two-dimensional detector for detecting radiation transmitted through a object between the radiation source and detector, and a computer. In this embodiment, the computer is configured to input the radiographic image data from the two-dimensional detector and to determine one or more materials that form the object by using an iterative analysis technique that selects the one or more materials from hierarchically arranged solution spaces of discrete material possibilities and selects the layer interfaces from the optimization of the continuous interface data.

  8. Applications of uncertainty analysis to visual evaluation of density in radiographs

    International Nuclear Information System (INIS)

    Uchida, Suguru; Ohtsuka, Akiyoshi; Fujita, Hiroshi.

    1981-01-01

    Uncertainty analysis, developed as a method of absolute judgment in psychology, is applied to a method of radiographic image evaluation with perceptual fluctuations and to an examination of visual evaluation of density in radiographs. Subjects are composed of three groups of four neurosurgeons, four radiologic technologists and four nonprofessionals. By using a five-category rating scale, each observer is directed to classify 255 radiographs randomly presented without feedback. Characteristics of each observer and each group can be shown quantitatively by calculated information values. It is also described that bivariate uncertainty analysis or entropy method can be used to calculate the degree of agreement of evaluation. (author)

  9. Applications of uncertainty analysis to visual evaluation of density in radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, S [Gifu Univ. (Japan); Ohtsuka, A; Fujita, H

    1981-03-01

    Uncertainty analysis, developed as a method of absolute judgment in psychology, is applied to a method of radiographic image evaluation with perceptual fluctuations and to an examination of visual evaluation of density in radiographs. Subjects are composed of three groups of four neurosurgeons, four radiologic technologists and four nonprofessionals. By using a five-category rating scale, each observer is directed to classify 255 radiographs randomly presented without feedback. Characteristics of each observer and each group can be shown quantitatively by calculated information values. It is also described that bivariate uncertainty analysis or entropy method can be used to calculate the degree of agreement of evaluation.

  10. Job stress and job satisfaction of physicians, radiographers, nurses and physicists working in radiotherapy: a multicenter analysis by the DEGRO Quality of Life Work Group

    Directory of Open Access Journals (Sweden)

    Bölling Tobias

    2009-02-01

    Full Text Available Abstract Background Ongoing changes in cancer care cause an increase in the complexity of cases which is characterized by modern treatment techniques and a higher demand for patient information about the underlying disease and therapeutic options. At the same time, the restructuring of health services and reduced funding have led to the downsizing of hospital care services. These trends strongly influence the workplace environment and are a potential source of stress and burnout among professionals working in radiotherapy. Methods and patients A postal survey was sent to members of the workgroup "Quality of Life" which is part of DEGRO (German Society for Radiooncology. Thus far, 11 departments have answered the survey. 406 (76.1% out of 534 cancer care workers (23% physicians, 35% radiographers, 31% nurses, 11% physicists from 8 university hospitals and 3 general hospitals completed the FBAS form (Stress Questionnaire of Physicians and Nurses; 42 items, 7 scales, and a self-designed questionnaire regarding work situation and one question on global job satisfaction. Furthermore, the participants could make voluntary suggestions about how to improve their situation. Results Nurses and physicians showed the highest level of job stress (total score 2.2 and 2.1. The greatest source of job stress (physicians, nurses and radiographers stemmed from structural conditions (e.g. underpayment, ringing of the telephone a "stress by compassion" (e.g. "long suffering of patients", "patients will be kept alive using all available resources against the conviction of staff". In multivariate analyses professional group (p In multivariate analyses "professional group" (p = 0.006 and "vocational experience" (p = 0.036 were associated with job satisfaction (cancer care workers with Conclusion Current workplace environments have a negative impact on stress levels and the satisfaction of radiotherapy staff. Identification and removal of the above-mentioned critical

  11. Observations of radiographer communication: An exploratory study using Transactional Analysis

    International Nuclear Information System (INIS)

    Booth, Lisa A.; Manning, David J.

    2006-01-01

    Purpose: Communication in medical imaging is a neglected area of research, despite the necessity for good communication if optimum diagnostic images are to be achieved. Methods: The present study has investigated the styles of communication used in medical imaging, using an approach known as Transactional Analysis. This approach has been demonstrated previously as having reliability and validity, using observations and supporting interviews with medical imaging staff, along with inter-rater observations of radiographer-patient interactions. Results: The results indicate that Transactional Analysis can be used effectively for identifying and naming interaction events in diagnostic radiography, with diagnostic radiographers using five styles of communication. Conclusion: Radiographers tend to use Parental styles of communicating; these styles are commonly associated with a practitioner-centred approach to dealing with patients which often result in non-adherence

  12. Radiographic analysis of shoulder anatomical arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Merolla, Giovanni [Unit of Shoulder and Elbow Surgery, ' D. Cervesi' Hospital, L. Van Beethoven 46 Street, 47841 Cattolica (Italy)], E-mail: gmerolla@shouldertech.it; Di Pietto, Francesco; Romano, Stefania [Department of Diagnostic Imaging, ' A. Cardarelli' Hospital, Naples (Italy); Paladini, Paolo; Campi, Fabrizio; Porcellini, Giuseppe [Unit of Shoulder and Elbow Surgery, ' D. Cervesi' Hospital, L. Van Beethoven 46 Street, 47841 Cattolica (Italy)

    2008-10-15

    Arthroplasty is the standard treatment for advanced shoulder osteoarthritis. Modern prostheses designs have modular features whose size, shaft/head and body morphology can be adjusted. Total Shoulder Arthroplasty (TSA) provides better results. A complete X-ray follow-up is essential to assess the results and evaluate the survival rates of a shoulder prosthesis. Antero-posterior at 40 deg. in both internal and external rotation (true AP view) and axillary view are recommended to assess the following parameters: orientation and translation of the humeral component, offset, size and height of the humeral head, acromio-humeral distance, distribution and fixation of the cement, stress shielding and cortical resorption, radiolucent lines, subsidence and tilt, glenoid wear and 'bone stock', prostheses instability, glenoid component shift. Shoulder hemiarthroplasty can lead to glenoid wear; the true AP film at 40 deg. of internal rotation provides the best profile of gleno-humeral joint to depict glenoid erosion. Shift of the glenoid component in TSA is identified as tilting or medial migration on true AP and axillary views in the early postoperative period (1-2 months) and at minimum of 2 years. An exhaustive radiographic analysis remains essential to monitor the prosthetic implant and detect early and late complications or risk factors of prosthetic loosening.

  13. Quantitative radiographic analysis of fiber reinforced polymer composites.

    Science.gov (United States)

    Baidya, K P; Ramakrishna, S; Rahman, M; Ritchie, A

    2001-01-01

    X-ray radiographic examination of the bone fracture healing process is a widely used method in the treatment and management of patients. Medical devices made of metallic alloys reportedly produce considerable artifacts that make the interpretation of radiographs difficult. Fiber reinforced polymer composite materials have been proposed to replace metallic alloys in certain medical devices because of their radiolucency, light weight, and tailorable mechanical properties. The primary objective of this paper is to provide a comparable radiographic analysis of different fiber reinforced polymer composites that are considered suitable for biomedical applications. Composite materials investigated consist of glass, aramid (Kevlar-29), and carbon reinforcement fibers, and epoxy and polyether-ether-ketone (PEEK) matrices. The total mass attenuation coefficient of each material was measured using clinical X-rays (50 kev). The carbon fiber reinforced composites were found to be more radiolucent than the glass and kevlar fiber reinforced composites.

  14. Theoretical analysis of radiographic images by nonstationary Poisson processes

    International Nuclear Information System (INIS)

    Tanaka, Kazuo; Uchida, Suguru; Yamada, Isao.

    1980-01-01

    This paper deals with the noise analysis of radiographic images obtained in the usual fluorescent screen-film system. The theory of nonstationary Poisson processes is applied to the analysis of the radiographic images containing the object information. The ensemble averages, the autocorrelation functions, and the Wiener spectrum densities of the light-energy distribution at the fluorescent screen and of the film optical-density distribution are obtained. The detection characteristics of the system are evaluated theoretically. Numerical examples one-dimensional image are shown and the results are compared with those obtained under the assumption that the object image is related to the background noise by the additive process. (author)

  15. Digital radiographic techniques in the analysis of paintings

    International Nuclear Information System (INIS)

    James, A.E. Jr.; Gibbs, S.J.; James, A.E. III; Pickens, D.R.; Sloan, M.; Price, R.R.; Erickson, J.J.

    1985-01-01

    In this chapter the authors use the term digital radiography to mean any method of radiographic image production in which the silver halide-based film is replaced by an electronic sensor for production of an image. There are essentially three types of digital radiographic systems available at present, but others will be developed. These differ primarily in the method of image production and the rapidity with which images can be produced. The three methods discussed are digital fluoroscopy, scanned projection radiography, and the scanned point source radiography. Each has certain characteristics which, if properly utilized, will allow improved x-ray analysis of paintings

  16. The interest of radiographical investigations of bone diseases in the selection of stallions [orthopedic lesions, abnormal radiographic findings, multivariate analysis

    International Nuclear Information System (INIS)

    Valette, J.P.; Touzot, G.; Denoix, J.M.

    1997-01-01

    Breeding of sport horses requires products with qualities for performance traits. The objectives of this study were to investigate the relation between radiographical examination and descendant of sires. Foots, fetlocks of both thoracic and pelvic limbs, carpus, tarsus and stifles were examined radiographically in 225 3-year old horses descent from 25 stallions. Data were analysed by multivariate analysis. Results indicate that descendant of a stallion presents the same abnormal radiographic findings. It is concluded that bone diseases are of great importance in breeding sport horses and that these abnormalities could have a genetic component [fr

  17. Measure by image analysis of industrial radiographs

    International Nuclear Information System (INIS)

    Brillault, B.

    1988-01-01

    A digital radiographic picture processing system for non destructive testing intends to provide the expert with computer tool, to precisely quantify radiographic images. The author describes the main problems, from the image formation to its characterization. She also insists on the necessity to define a precise process in order to automatize the system. Some examples illustrate the efficiency of digital processing for radiographic images [fr

  18. Comparative radiographic analysis on the anatomical axis in knee osteoarthritis cases: inter and intraobserver evaluation.

    Science.gov (United States)

    Matos, Luiz Felipe; Giordano, Marcos; Cardoso, Gustavo Novaes; Farias, Rafael Baptista; E Albuquerque, Rodrigo Pires

    2015-01-01

    To make a comparative inter and intraobserver analysis on measurements of the anatomical axis between panoramic radiographs of the lower limbs in anteroposterior (AP) view with bipedal weight-bearing, on short film. An accuracy study comparing radiographic measurements on 47 knees of patients attending the knee surgery outpatient clinic due to osteoarthritis. The radiographic evaluation used was as standardized for the total knee arthroplasty program, including panoramic AP views of the lower limbs and short radiographs of the knees in AP and lateral views, all with bipedal weight-bearing. Following this, the anatomical axis of the lower limbs or the femorotibial angle was measured by five independent examiners on the panoramic and short AP radiographs; three of the examiners were considered to be more experienced and two, less experienced. All the measurements were made again by the same examiners after an interval of not less than 15 days. The statistical analysis was performed using the intraclass correlation coefficient, in order to evaluate the inter and intraobserver concordance of the anatomical axis measurements. From the statistical analysis, it was observed that there was strongly significant concordance between the anatomical axis measurements on the panoramic and short radiographs, for all the five examiners and for both measurements. Under the conditions studied, short radiographs were equivalent to panoramic radiographs for evaluating the anatomical axis of the lower limbs in patients with advanced osteoarthritis. The measurements used also showed high rates of inter and intraobserver concordance and reproducibility.

  19. Biometric Analysis - A Reliable Indicator for Diagnosing Taurodontism using Panoramic Radiographs.

    Science.gov (United States)

    Hegde, Veda; Anegundi, Rajesh Trayambhak; Pravinchandra, K R

    2013-08-01

    Taurodontism is a clinical entity with a morpho-anatomical change in the shape of the tooth, which was thought to be absent in modern man. Taurodontism is mostly observed as an isolated trait or a component of a syndrome. Various techniques have been devised to diagnose taurodontism. The aim of this study was to analyze whether a biometric analysis was useful in diagnosing taurodontism, in radiographs which appeared to be normal on cursory observations. This study was carried out in our institution by using radiographs which were taken for routine procedures. In this retrospective study, panoramic radiographs were obtained from dental records of children who were aged between 9-14 years, who did not have any abnormality on cursory observations. Biometric analyses were carried out on permanent mandibular first molar(s) by using a novel biometric method. The values were tabulated and analysed. Fischer exact probability test, Chi square test and Chi-square test with Yates correction were used for statistical analysis of the data. Cursory observation did not yield us any case of taurodontism. In contrast, the biometric analysis yielded us a statistically significant number of cases of taurodontism. However, there was no statistically significant difference in the number of cases with taurodontism, which was obtained between the genders and the age group which was considered. Thus, taurodontism was diagnosed on a biometric analysis, which was otherwise missed on a cursory observation. It is therefore necessary from the clinical point of view, to diagnose even the mildest form of taurodontism by using metric analysis rather than just relying on a visual radiographic assessment, as its occurrence has many clinical implications and a diagnostic importance.

  20. A radiographic analysis of implant component misfit.

    LENUS (Irish Health Repository)

    Sharkey, Seamus

    2011-07-01

    Radiographs are commonly used to assess the fit of implant components, but there is no clear agreement on the amount of misfit that can be detected by this method. This study investigated the effect of gap size and the relative angle at which a radiograph was taken on the detection of component misfit. Different types of implant connections (internal or external) and radiographic modalities (film or digital) were assessed.

  1. Comparative radiographic analysis on the anatomical axis in knee osteoarthritis cases: inter and intraobserver evaluation

    Directory of Open Access Journals (Sweden)

    Luiz Felipe Matos

    2015-06-01

    Full Text Available OBJECTIVE: To make a comparative inter and intraobserver analysis on measurements of the anatomical axis between panoramic radiographs of the lower limbs in anteroposterior (AP view with bipedal weight-bearing, on short film.METHODS: An accuracy study comparing radiographic measurements on 47 knees of patients attending the knee surgery outpatient clinic due to osteoarthritis. The radiographic evaluation used was as standardized for the total knee arthroplasty program, including panoramic AP views of the lower limbs and short radiographs of the knees in AP and lateral views, all with bipedal weight-bearing. Following this, the anatomical axis of the lower limbs or the femorotibial angle was measured by five independent examiners on the panoramic and short AP radiographs; three of the examiners were considered to be more experienced and two, less experienced. All the measurements were made again by the same examiners after an interval of not less than 15 days. The statistical analysis was performed using the intraclass correlation coefficient, in order to evaluate the inter and intraobserver concordance of the anatomical axis measurements.RESULTS: From the statistical analysis, it was observed that there was strongly significant concordance between the anatomical axis measurements on the panoramic and short radiographs, for all the five examiners and for both measurements.CONCLUSIONS: Under the conditions studied, short radiographs were equivalent to panoramic radiographs for evaluating the anatomical axis of the lower limbs in patients with advanced osteoarthritis. The measurements used also showed high rates of inter and intraobserver concordance and reproducibility.

  2. Job stress and job satisfaction of physicians, radiographers, nurses and physicists working in radiotherapy: a multicenter analysis by the DEGRO Quality of Life Work Group.

    Science.gov (United States)

    Sehlen, Susanne; Vordermark, Dirk; Schäfer, Christof; Herschbach, Peter; Bayerl, Anja; Pigorsch, Steffi; Rittweger, Jutta; Dormin, Claudia; Bölling, Tobias; Wypior, Hans Joachim; Zehentmayr, Franz; Schulze, Wolfgang; Geinitz, Hans

    2009-02-06

    Ongoing changes in cancer care cause an increase in the complexity of cases which is characterized by modern treatment techniques and a higher demand for patient information about the underlying disease and therapeutic options. At the same time, the restructuring of health services and reduced funding have led to the downsizing of hospital care services. These trends strongly influence the workplace environment and are a potential source of stress and burnout among professionals working in radiotherapy. A postal survey was sent to members of the workgroup "Quality of Life" which is part of DEGRO (German Society for Radiooncology). Thus far, 11 departments have answered the survey. 406 (76.1%) out of 534 cancer care workers (23% physicians, 35% radiographers, 31% nurses, 11% physicists) from 8 university hospitals and 3 general hospitals completed the FBAS form (Stress Questionnaire of Physicians and Nurses; 42 items, 7 scales), and a self-designed questionnaire regarding work situation and one question on global job satisfaction. Furthermore, the participants could make voluntary suggestions about how to improve their situation. Nurses and physicians showed the highest level of job stress (total score 2.2 and 2.1). The greatest source of job stress (physicians, nurses and radiographers) stemmed from structural conditions (e.g. underpayment, ringing of the telephone) a "stress by compassion" (e.g. "long suffering of patients", "patients will be kept alive using all available resources against the conviction of staff"). In multivariate analyses professional group (p working night shifts (p = 0.001), age group (p = 0.012) and free time compensation (p = 0.024) gained significance for total FBAS score. Global job satisfaction was 4.1 on a 9-point scale (from 1 - very satisfied to 9 - not satisfied). Comparing the total stress scores of the hospitals and job groups we found significant differences in nurses (p = 0.005) and physicists (p = 0.042) and a borderline

  3. Foreign object detection and removal to improve automated analysis of chest radiographs

    International Nuclear Information System (INIS)

    Hogeweg, Laurens; Sánchez, Clara I.; Melendez, Jaime; Maduskar, Pragnya; Ginneken, Bram van; Story, Alistair; Hayward, Andrew

    2013-01-01

    Purpose: Chest radiographs commonly contain projections of foreign objects, such as buttons, brassier clips, jewellery, or pacemakers and wires. The presence of these structures can substantially affect the output of computer analysis of these images. An automated method is presented to detect, segment, and remove foreign objects from chest radiographs.Methods: Detection is performed using supervised pixel classification with a kNN classifier, resulting in a probability estimate per pixel to belong to a projected foreign object. Segmentation is performed by grouping and post-processing pixels with a probability above a certain threshold. Next, the objects are replaced by texture inpainting.Results: The method is evaluated in experiments on 257 chest radiographs. The detection at pixel level is evaluated with receiver operating characteristic analysis on pixels within the unobscured lung fields and an A z value of 0.949 is achieved. Free response operator characteristic analysis is performed at the object level, and 95.6% of objects are detected with on average 0.25 false positive detections per image. To investigate the effect of removing the detected objects through inpainting, a texture analysis system for tuberculosis detection is applied to images with and without pathology and with and without foreign object removal. Unprocessed, the texture analysis abnormality score of normal images with foreign objects is comparable to those with pathology. After removing foreign objects, the texture score of normal images with and without foreign objects is similar, while abnormal images, whether they contain foreign objects or not, achieve on average higher scores.Conclusions: The authors conclude that removal of foreign objects from chest radiographs is feasible and beneficial for automated image analysis

  4. Semi-automated digital image analysis of patellofemoral joint space width from lateral knee radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Grochowski, S.J. [Mayo Clinic, Department of Orthopedic Surgery, Rochester (United States); Amrami, K.K. [Mayo Clinic, Department of Radiology, Rochester (United States); Kaufman, K. [Mayo Clinic, Department of Orthopedic Surgery, Rochester (United States); Mayo Clinic/Foundation, Biomechanics Laboratory, Department of Orthopedic Surgery, Charlton North L-110L, Rochester (United States)

    2005-10-01

    To design a semi-automated program to measure minimum patellofemoral joint space width (JSW) using standing lateral view radiographs. Lateral patellofemoral knee radiographs were obtained from 35 asymptomatic subjects. The radiographs were analyzed to report both the repeatability of the image analysis program and the reproducibility of JSW measurements within a 2 week period. The results were also compared with manual measurements done by an experienced musculoskeletal radiologist. The image analysis program was shown to have an excellent coefficient of repeatability of 0.18 and 0.23 mm for intra- and inter-observer measurements respectively. The manual method measured a greater minimum JSW than the automated method. Reproducibility between days was comparable to other published results, but was less satisfactory for both manual and semi-automated measurements. The image analysis program had an inter-day coefficient of repeatability of 1.24 mm, which was lower than 1.66 mm for the manual method. A repeatable semi-automated method for measurement of the patellofemoral JSW from radiographs has been developed. The method is more accurate than manual measurements. However, the between-day reproducibility is higher than the intra-day reproducibility. Further investigation of the protocol for obtaining sequential lateral knee radiographs is needed in order to reduce the between-day variability. (orig.)

  5. Operational parameters analysis of the radiographic technique through the modulation transfer function

    International Nuclear Information System (INIS)

    Motta, Mauricio Saldanha; Guimaraes, Ari Sauer

    1995-01-01

    The influence of the focal size and image magnification variations on the radiographic final image is studied. The analysis used the modulation transfer function for evaluating the ratio of the radiographic image amplitude and that of the inspected object. it was concluded that the increase of the focal size and of the magnifications are not good for the image quality. 3 refs., 4 figs., 1 tab

  6. Australian rural radiographers' perspectives on disclosure of their radiographic opinion to patients

    International Nuclear Information System (INIS)

    Squibb, Kathryn; Bull, Rosalind M.; Smith, Anthony; Dalton, Lisa

    2015-01-01

    The role of Australian rural radiographers in radiographic interpretation, communication and disclosure of their radiographic opinion with a specific focus on plain film radiography was examined in a two phase, exploratory interpretive study. Data were collected using questionnaires and interviews and analysed thematically. This reports one of the key themes identified in the thematic data analysis. ‘Disclosure of Radiographic Opinion to Patients’ comprises the three interrelated sub-themes Acting Ethically, Selective Disclosure and Filtered Truth. It is wholly concerned with the ways in which rural radiographers choose to disclose their radiographic opinion to patients. Without a clear picture of where they stand medico-legally, rural radiographers draw on experience and a strong ethical framework as the basis for these complex decisions. Rural radiographers frame their disclosures to patients in a manner that is governed by the diagnostic, therapeutic and emotional impact the information disclosed may have on the patient. Disclosure to patients was found to be selective, often diagnostically vague and ethically filtered

  7. Job stress and job satisfaction of physicians, radiographers, nurses and physicists working in radiotherapy: a multicenter analysis by the DEGRO Quality of Life Work Group

    International Nuclear Information System (INIS)

    Sehlen, Susanne; Wypior, Hans Joachim; Zehentmayr, Franz; Schulze, Wolfgang; Geinitz, Hans; Vordermark, Dirk; Schäfer, Christof; Herschbach, Peter; Bayerl, Anja; Pigorsch, Steffi; Rittweger, Jutta; Dormin, Claudia; Bölling, Tobias

    2009-01-01

    Ongoing changes in cancer care cause an increase in the complexity of cases which is characterized by modern treatment techniques and a higher demand for patient information about the underlying disease and therapeutic options. At the same time, the restructuring of health services and reduced funding have led to the downsizing of hospital care services. These trends strongly influence the workplace environment and are a potential source of stress and burnout among professionals working in radiotherapy. A postal survey was sent to members of the workgroup 'Quality of Life' which is part of DEGRO (German Society for Radiooncology). Thus far, 11 departments have answered the survey. 406 (76.1%) out of 534 cancer care workers (23% physicians, 35% radiographers, 31% nurses, 11% physicists) from 8 university hospitals and 3 general hospitals completed the FBAS form (Stress Questionnaire of Physicians and Nurses; 42 items, 7 scales), and a self-designed questionnaire regarding work situation and one question on global job satisfaction. Furthermore, the participants could make voluntary suggestions about how to improve their situation. Nurses and physicians showed the highest level of job stress (total score 2.2 and 2.1). The greatest source of job stress (physicians, nurses and radiographers) stemmed from structural conditions (e.g. underpayment, ringing of the telephone) a 'stress by compassion' (e.g. 'long suffering of patients', 'patients will be kept alive using all available resources against the conviction of staff'). In multivariate analyses professional group (p < 0.001), working night shifts (p = 0.001), age group (p = 0.012) and free time compensation (p = 0.024) gained significance for total FBAS score. Global job satisfaction was 4.1 on a 9-point scale (from 1 – very satisfied to 9 – not satisfied). Comparing the total stress scores of the hospitals and job groups we found significant differences in nurses (p = 0

  8. Biometric Analysis – A Reliable Indicator for Diagnosing Taurodontism using Panoramic Radiographs

    Science.gov (United States)

    Hegde, Veda; Anegundi, Rajesh Trayambhak; Pravinchandra, K.R.

    2013-01-01

    Background: Taurodontism is a clinical entity with a morpho–anatomical change in the shape of the tooth, which was thought to be absent in modern man. Taurodontism is mostly observed as an isolated trait or a component of a syndrome. Various techniques have been devised to diagnose taurodontism. Aim: The aim of this study was to analyze whether a biometric analysis was useful in diagnosing taurodontism, in radiographs which appeared to be normal on cursory observations. Setting and Design: This study was carried out in our institution by using radiographs which were taken for routine procedures. Material and Methods: In this retrospective study, panoramic radiographs were obtained from dental records of children who were aged between 9–14 years, who did not have any abnormality on cursory observations. Biometric analyses were carried out on permanent mandibular first molar(s) by using a novel biometric method. The values were tabulated and analysed. Statistics: Fischer exact probability test, Chi square test and Chi-square test with Yates correction were used for statistical analysis of the data. Results: Cursory observation did not yield us any case of taurodontism. In contrast, the biometric analysis yielded us a statistically significant number of cases of taurodontism. However, there was no statistically significant difference in the number of cases with taurodontism, which was obtained between the genders and the age group which was considered. Conclusion: Thus, taurodontism was diagnosed on a biometric analysis, which was otherwise missed on a cursory observation. It is therefore necessary from the clinical point of view, to diagnose even the mildest form of taurodontism by using metric analysis rather than just relying on a visual radiographic assessment, as its occurrence has many clinical implications and a diagnostic importance. PMID:24086912

  9. Comparative analysis of human and bovine teeth: radiographic density

    Directory of Open Access Journals (Sweden)

    Jefferson Luis Oshiro Tanaka

    2008-12-01

    Full Text Available Since bovine teeth have been used as substitutes for human teeth in in vitro dental studies, the aim of this study was to compare the radiographic density of bovine teeth with that of human teeth to evaluate their usability for radiographic studies. Thirty bovine and twenty human teeth were cut transversally in 1 millimeter-thick slices. The slices were X-rayed using a digital radiographic system and an intraoral X-ray machine at 65 kVp and 7 mA. The exposure time (0.08 s and the target-sensor distance (40 cm were standardized for all the radiographs. The radiographic densities of the enamel, coronal dentin and radicular dentin of each slice were obtained separately using the "histogram" tool of Adobe Photoshop 7.0 software. The mean radiographic densities of the enamel, coronal dentin and radicular dentin were calculated by the arithmetic mean of the slices of each tooth. One-way ANOVA demonstrated statistically significant differences for the densities of bovine and human enamel (p 0.05. Based on the results, the authors concluded that: a the radiographic density of bovine enamel is significantly higher than that of human enamel; b the radiodensity of bovine coronal dentin is statistically lower than the radiodensity of human coronal dentin; bovine radicular dentin is also less radiodense than human radicular dentin, although this difference was not statistically significant; c bovine teeth should be used with care in radiographic in vitro studies.

  10. Weight bearing cone beam CT scan versus gravity stress radiography for analysis of supination external rotation injuries of the ankle.

    Science.gov (United States)

    Marzo, John M; Kluczynski, Melissa A; Clyde, Corey; Anders, Mark J; Mutty, Christopher E; Ritter, Christopher A

    2017-12-01

    For AO 44-B2 ankle fractures of uncertain stability, the current diagnostic standard is to obtain a gravity stress radiograph, but some have advocated for the use of weight-bearing radiographs. The primary aim was to compare measures of medial clear space (MCS) on weight-bearing cone beam computed tomography (CBCT) scans versus gravity stress radiographs for determining the state of stability of ankle fractures classified as AO SER 44-B2 or Weber B. The secondary aim was to evaluate the details offered by CBCT scans with respect to other findings that may be relevant to patient care. Nine patients were enrolled in this cross-sectional study between April 2016 and February 2017 if they had an AO SER 44-B2 fracture of uncertain stability, had a gravity stress radiograph, and were able to undergo CT scan within seven days. The width of the MCS was measured at the level of the talar dome on all radiographs and at the mid coronal slice on CT. Wilcoxon signed-ranks tests were used to compare MCS between initial radiographs, gravity stress radiographs and weight-bearing CBCT scans. MCS on weight-bearing CBCT scan (1.41±0.41 mm) was significantly less than standard radiographs (3.28±1.63 mm, P=0.004) and gravity stress radiographs (5.82±1.93 mm, P=0.02). There was no statistically significant difference in MCS measured on standard radiographs versus gravity stress radiographs (P=0.11). Detailed review of the multiplanar CT images revealed less than perfect anatomical reduction of the fractures, with residual fibular shortening, posterior displacement, and fracture fragments in the incisura as typical findings. Similar to weight-bearing radiographs, weight-bearing CBCT scan can predict stability of AO 44-B2 ankle fractures by showing restoration of the MCS, and might be used to indicate patients for non-operative treatment. None of the fractures imaged in this study were perfectly reduced however, and further clinical research is necessary to determine if any of the

  11. Quantitative analysis of bowel gas by plain abdominal radiograph combined with computer image processing

    International Nuclear Information System (INIS)

    Gao Yan; Peng Kewen; Zhang Houde; Shen Bixian; Xiao Hanxin; Cai Juan

    2003-01-01

    Objective: To establish a method for quantitative analysis of bowel gas by plain abdominal radiograph and computer graphics. Methods: Plain abdominal radiographs in supine position from 25 patients with irritable bowel syndrome (IBS) and 20 health controls were studied. A gastroenterologist and a radiologist independently conducted the following procedure on each radiograph. After the outline of bowel gas was traced by axe pen, the radiograph was digitized by a digital camera and transmitted to the computer with Histogram software. The total gas area was determined as the pixel value on images. The ratio of the bowel gas quantity to the pixel value in the region surrounded by a horizontal line tangential to the superior pubic symphysis margin, a horizontal line tangential to the tenth dorsal vertebra inferior margin, and the lateral line tangential to the right and left anteriosuperior iliac crest, was defined as the gas volume score (GVS). To examine the sequential reproducibility, a second plain abdominal radiograph was performed in 5 normal controls 1 week later, and the GVS were compared. Results: Bowel gas was easily identified on the plain abdominal radiograph. Both large and small intestine located in the selected region. Both observers could finish one radiographic measurement in less than 10 mins. The correlation coefficient between the two observers was 0.986. There was no statistical difference on GVS between the two sequential radiographs in 5 health controls. Conclusion: Quantification of bowel gas based on plain abdominal radiograph and computer is simple, rapid, and reliable

  12. Radiographic analysis of partial or total vertebral body resection

    International Nuclear Information System (INIS)

    Whitten, C.G.; Hammer, G.H.; El-Khoury, G.Y.; Hugus, J.; Weinstein, J.N.

    1991-01-01

    Partial and total vertebrectomies are used in the treatment of primary and metastatic neoplasms of the spine. Serial radiographic studies are crucial in the follow-up of patients with vertebrectomies. This paper presents 33 cases and illustrates radiographic examples of both successful and complicated vertebrectomies, including radiographic signs of local tumor recurrence, loosening, migration or fracture of the hardware or methylmethacrylate, bone graft failure, and progressive spinal instability

  13. Radiographer commenting of trauma radiographs: a survey of the benefits, barriers and enablers to participation in an Australian healthcare setting

    International Nuclear Information System (INIS)

    Neep, Michael J.; Steffens, Tom; Owen, Rebecca; McPhail, Steven M.

    2014-01-01

    Radiographer abnormality detection systems that highlight abnormalities on trauma radiographs ('red dot' system) have been operating for more than 30 years. Recently, a number of pitfalls have been identified. These limitations initiated the evolution of a radiographer commenting system, whereby a radiographer provides a brief description of abnormalities identified in emergency healthcare settings. This study investigated radiographers' participation in abnormality detection systems, their perceptions of benefits, barriers and enablers to radiographer commenting, and perceptions of potential radiographer image interpretation services for emergency settings. A cross-sectional survey was implemented. Participants included radiographers from four metropolitan hospitals in Queensland, Australia. Conventional descriptive statistics, histograms and thematic analysis were undertaken. Seventy-three surveys were completed and included in the analysis (68% response rate); 30 (41%) of respondents reported participating in abnormality detection in 20% or less of examinations, and 26(36%) reported participating in 80% or more of examinations. Five overarching perceived benefits of radiographer commenting were identified: assisting multidisciplinary teams, patient care, radiographer ability, professional benefits and quality of imaging. Frequently reported perceived barriers included 'difficulty accessing image interpretation education', 'lack of time' and 'low confidence in interpreting radiographs'. Perceived enablers included 'access to image interpretation education' and 'support from radiologist colleagues'. A range of factors are likely to contribute to the successful implementation of radiographer commenting in addition to abnormality detection in emergency settings. Effective image interpretation education amenable to completion by radiographers would likely prove valuable in preparing radiographers for participation in abnormality detection and commenting systems in

  14. Radiographic analysis of pasteurized autologous bone graft

    International Nuclear Information System (INIS)

    Ahmed, Adel Refaat; Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi

    2003-01-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  15. Radiographic analysis of pasteurized autologous bone graft

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Adel Refaat [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan); Department of Orthopedic Surgery, Alexandria University, Alexandria (Egypt); Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan)

    2003-08-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  16. Retrospective panoramic radiographic analysis for idiopathic osteosclerosis in Indians

    Directory of Open Access Journals (Sweden)

    Srikanth H Srivathsa

    2016-01-01

    Full Text Available Introduction: Idiopathic osteosclerosis is an area of increased radiodensity observed on panoramic radiographs. The prevalence of this entity is not known, especially in Indians. Aims and Objectives: To determine the prevalence and epidemiological characteristics of idiopathic osteosclerosis. Materials and Methods: Six hundred and forty panoramic radiographs were retrospectively analyzed for the presence of idiopathic osteosclerosis by a single trained oral radiologist. Statistical Analysis: The data obtained were analyzed using Microsoft Excel (Version 2007 for Windows. Results: Idiopathic osteosclerosis was identified in 32 individuals with a prevalence of 5%. There were 21 female (65.7% and 11 male (34.3% participants. There were 31 single, unilateral (96.85% osteosclerotic lesions and 1 (3.15% bilateral lesion. Right side localization was noted in 19 participants (57.57% and left side localization in 14 participants (42.42%. Conclusion: This study illustrates the prevalence of idiopathic osteosclerosis in Indians. Further, it depicts the characteristics of idiopathic osteosclerotic lesions.

  17. Radiographic alterations of the frontal sinus morphology according to variations of the vertical angle in posteroanterior radiographs of the skull

    Directory of Open Access Journals (Sweden)

    Rhonan Ferreira Silva

    2014-03-01

    The frontal sinuses play a highly relevant role in comparative human identification processes. Since forensic radiology is a branch in the forensic sciences, adequate radiological analysis of the frontal sinuses is essential for comparative human identifications. The current study investigates radiographic morphological changes in the frontal sinuses according to vertical angle distortions in posteroanterior (PA radiographs. A standard PA radiograph of the skull of an adult was obtained. Eight addition PA radiographs were taken at different vertical angles. Frontal sinuses were analyzed qualitatively and quantitatively according to Ribeiro´s (2000 technique. Both qualitative and quantitative analyses revealed significant image distortions. Further, overlapping anatomical structures were reported when PA radiographs were analyzed in negative angulation distortions (from -10° to -40°. Positive and negative angular distortions up to 20º slightly affected the qualitative morphological analysis. However, 10° positive and negative distortions provided a significant interference in quantitative analysis and impaired the measuring process. Most forensic techniques for the analysis of frontal sinuses comprise measurements of morphological distances. Distortions of approximately 10° or over in vertical angulation of cranial PA radiographs should be avoided so that more accurate comparative human identifications could be achieved.

  18. A pilot study to determine the effect of radiographer training on radiostereometric analysis imaging technique

    DEFF Research Database (Denmark)

    Muharemovic, O; Troelsen, A; Thomsen, M G

    2018-01-01

    INTRODUCTION: Producing x-ray images for radiostereometric analysis (RSA) is a demanding technique. Suboptimal examinations result in a high percentage of exposure repetition. The aim of this pilot study was to use an experiential training approach to sharpen the skills of radiographers in acquir......INTRODUCTION: Producing x-ray images for radiostereometric analysis (RSA) is a demanding technique. Suboptimal examinations result in a high percentage of exposure repetition. The aim of this pilot study was to use an experiential training approach to sharpen the skills of radiographers...

  19. Computer-assisted analysis of cervical vertebral bone age using cephalometric radiographs in Brazilian subjects.

    Science.gov (United States)

    Caldas, Maria de Paula; Ambrosano, Gláucia Maria Bovi; Haiter Neto, Francisco

    2010-01-01

    The aims of this study were to develop a computerized program for objectively evaluating skeletal maturation on cephalometric radiographs, and to apply the new method to Brazilian subjects. The samples were taken from the patient files of Oral Radiological Clinics from the North, Northeast, Midwest and South regions of the country. A total of 717 subjects aged 7.0 to 15.9 years who had lateral cephalometric radiographs and hand-wrist radiographs were selected. A cervical vertebral computerized analysis was created in the Radiocef Studio 2 computer software for digital cephalometric analysis, and cervical vertebral bone age was calculated using the formulas developed by Caldas et al.17 (2007). Hand-wrist bone age was evaluated by the TW3 method. Analysis of variance (ANOVA) and the Tukey test were used to compare cervical vertebral bone age, hand-wrist bone age and chronological age (P cervical vertebral bone age and chronological age in all regions studied. When analyzing bone age, it was possible to observe a statistically significant difference between cervical vertebral bone age and hand-wrist bone age for female and male subjects in the North and Northeast regions, as well as for male subjects in the Midwest region. No significant difference was observed between bone age and chronological age in all regions except for male subjects in the North and female subjects in the Northeast. Using cervical vertebral bone age, it might be possible to evaluate skeletal maturation in an objective manner using cephalometric radiographs.

  20. Bone stress: a radionuclide imaging perspective

    International Nuclear Information System (INIS)

    Roub, L.W.; Gumerman, L.W.; Hanley, E.N. Jr.; Clark, M.W.; Goodman, M.; Herbert, D.L.

    1979-01-01

    Thirty-five college athletes with lower leg pain underwent radiography and radionuclide studies to rule out a stress fracture. Their asymptomatic extremities and 13 pain-free athletes served as controls. Four main patterns were observed: (a) sharply marginated scintigraphic abnormalities and positive radiographs; (b) sharply marginated scintigraphic abnormalities and negatives radiographs; (c) ill-defined scintigraphic abnormalities and negative radiographs; and (d) negative radionuclide images and negative radiographs. Since the patients with the first two patterns were otherwise identical medically, the authors feel that this scintigraphic appearance is characterisic of bone stress in the appropriate clinical setting, regardless of the radiographic findings. A schema is proposed to explain the occurrence of positive radionuclide images and negative radiographs in the same patient, using a broad conceptual approach to the problem of bone stress

  1. Can Australian radiographers assess screening mammograms accurately? Biennial follow-up from a four year prospective study and lesion analysis

    International Nuclear Information System (INIS)

    Moran, S.; Warren-Forward, H.

    2016-01-01

    Introduction: Globally, the role of the radiographer is changing; some countries have developed advanced roles with specific scopes of practice. Other countries, like Australia, are in the process of this change. This paper demonstrates the abilities of Australian radiographers in mammogram screen reading, highlighting some of their specific difficulties with different lesion types. Method: Six experienced radiographers participated in a prospective study, screen reading 2000 mammograms each between 2010 and 2011. This paper looks at the results of those same women at biennial re-screen. Analysis of the results included validation of normal results by negative follow-up screens and new cancers at biennial review; there is also analysis on the types of lesions detected and missed. Results: After biennial review, three cancers in 2013/2014 had been marked as abnormal by one radiographer two years prior, which increased her sensitivity from 64% to 85%. Sensitivity for the radiologists decreased from the assumed 100% to 95%. Radiographers appeared to be skilled in detection of calcifications and architectural distortions but had difficulty with non-specific densities. Conclusion: This study demonstrates the potential for Australian radiographers to enhance the accuracy of screen reading programs. - Highlights: • Radiographers have the potential to increase breast cancer detection rates. • Radiographers appear to be skilled at detecting calcifications. • Lesions commonly overlooked by radiographers could be targeted for training.

  2. Radiographic bone loss in a Scottish non-smoking Type 1 Diabetes mellitus population; a Bitewing Radiographic Study.

    Science.gov (United States)

    Plessas, Anastasios; Robertson, Douglas P; Hodge, Penny J

    2018-05-15

    The dental complications of uncontrolled diabetes include reduced salivary flow rate, candidiasis and periodontal manifestations. A recent meta-analysis concluded that diabetes patients have a significantly higher severity, but not extent, of destructive periodontal disease than non-diabetes people. The authors reported that most type-1 diabetes studies using dental radiographic data have not controlled for confounding factors such as smoking. The aim of this cross-sectional study was to compare radiographic alveolar bone loss between type 1 diabetes (T1DM) and non-diabetes (NDM) participants in a Scottish non-smoking population. Digital bitewing radiographs for 174 Scottish adult never or ex-smoker (> 5 years) participants (108 T1DM, 66 NDS), recruited from outpatient clinics throughout Greater Glasgow and Clyde, were included in the analysis. A single blinded, trained and calibrated examiner recorded the radiographic bone loss seen on bitewing radiographs using the digital screen caliper. The bone loss was measured as the distance between the cemento-enamel junction (CEJ) and the deepest radiographic alveolar bone margin interproximally of each tooth. T1DM participants had more radiographic alveolar bone loss throughout the all teeth measured (median:1.27 mm vs 1.06 mm, P diabetes subjects. Patients suffering from type 1 diabetes are at higher risk of periodontitis even when controlling for multiple possible confounding factors and this difference can be detected on routine dental radiographs at an early stage. These data confirm radiographically the previously reported association between T1DM and periodontal bone loss. This article is protected by copyright. All rights reserved. © 2018 American Academy of Periodontology.

  3. Computer-assisted analysis of cervical vertebral bone age using cephalometric radiographs in Brazilian subjects

    Directory of Open Access Journals (Sweden)

    Maria de Paula Caldas

    2010-03-01

    Full Text Available The aims of this study were to develop a computerized program for objectively evaluating skeletal maturation on cephalometric radiographs, and to apply the new method to Brazilian subjects. The samples were taken from the patient files of Oral Radiological Clinics from the North, Northeast, Midwest and South regions of the country. A total of 717 subjects aged 7.0 to 15.9 years who had lateral cephalometric radiographs and hand-wrist radiographs were selected. A cervical vertebral computerized analysis was created in the Radiocef Studio 2 computer software for digital cephalometric analysis, and cervical vertebral bone age was calculated using the formulas developed by Caldas et al.17 (2007. Hand-wrist bone age was evaluated by the TW3 method. Analysis of variance (ANOVA and the Tukey test were used to compare cervical vertebral bone age, hand-wrist bone age and chronological age (P < 0.05. No significant difference was found between cervical vertebral bone age and chronological age in all regions studied. When analyzing bone age, it was possible to observe a statistically significant difference between cervical vertebral bone age and hand-wrist bone age for female and male subjects in the North and Northeast regions, as well as for male subjects in the Midwest region. No significant difference was observed between bone age and chronological age in all regions except for male subjects in the North and female subjects in the Northeast. Using cervical vertebral bone age, it might be possible to evaluate skeletal maturation in an objective manner using cephalometric radiographs.

  4. Is the owner entitled to radiographs taken of his animal?

    International Nuclear Information System (INIS)

    Hartung, K.

    1990-01-01

    In the Federal Republic of Germany a veterinarian owns radiographs taken of animals in his practice. They have to be filed like any other results of diagnostic procedures. This is important, because evidence is required in the case of a law suit. On the other hand, it has to be stressed that taking radiographs is the subject of a free contract between owner and veterinarian. So it is possible to take the radiographs solely with the purpose of giving them to the owner, who may have them analysed by any other veterinarian of his choice. This is especially true in hip radiographs, which are evaluated and filed by an adjudicator of the breed association. In any case the radiologist has the obligation to lend the radiographs to another veterinarian on request for inspection. The second veterinarian has to give them back as soon as possible

  5. Quantitative analysis of real-time radiographic systems

    International Nuclear Information System (INIS)

    Barker, M.D.; Condon, P.E.; Barry, R.C.; Betz, R.A.; Klynn, L.M.

    1988-01-01

    A method was developed which yields quantitative information on the spatial resolution, contrast sensitivity, image noise, and focal spot size from real time radiographic images. The method uses simple image quality indicators and computer programs which make it possible to readily obtain quantitative performance measurements of single or multiple radiographic systems. It was used for x-ray and optical images to determine which component of the system was not operating up to standard. Focal spot size was monitored by imaging a bar pattern. This paper constitutes the second progress report on the development of the camera and radiation image quality indicators

  6. Radiographic evaluations

    International Nuclear Information System (INIS)

    Williams, J.L.

    1988-01-01

    The author describes how to: perform a systematic evaluation of a chest radiograph; state the classic radiographic description of hyaline membrane disease; list the conditions that cause hyperaeration and describe the radiologic feature of hyperaeration; describe the radiograph of a patient with a congenital diaphragmatic hernia; identify optimum placement of an endotracheal tube, gastric feeding tube, and umbilical artery catheter on a radiograph; differentiate between pulmonary interstitial air and hyaline membrane disease; select radiographic features that would indicate the presence of a tension pneumothorax; describe a lateral decubitus projection and state the type of problem it is most often used to identify; explain the procedure used in obtaining a lateral neck radiograph and list two problems that may require this view; and describe the radiograph of a patient with cystic fibrosis

  7. Occupational health and the radiographer

    International Nuclear Information System (INIS)

    Stronach, T.

    1990-01-01

    This paper identifies some of the occupational health hazards faced by radiographers in the hospital environment. There has been very little work done in this area in the past, and as the subject is so large this paper can do little other than raise some of the issues . The hazards addressed include: radiation, ergonomics, chemical, environmental, biological, occupational injury and accident, stress. 14 refs., 2 figs

  8. Radiographic interpretation of the appendicular skeleton: A comparison between casualty officers, nurse practitioners and radiographers

    International Nuclear Information System (INIS)

    Coleman, Liz; Piper, Keith

    2009-01-01

    Aim: To assess how accurately and confidently casualty officers, nurse practitioners and radiographers, practicing within the emergency department (ED), recognize and describe radiographic trauma within an image test bank of 20 appendicular radiographs. Method: The participants consisted of 7 casualty officers, 13 nurse practitioners and 18 radiographers. All 20 radiographic examinations selected for the image test bank had been acquired following trauma and included some subtle, yet clinically significant abnormalities. The test bank score (maximum 40 marks), sensitivity and specificity percentages were calculated against an agreed radiological diagnosis (reference standard). Alternative Free-response Receiver Operating Characteristic (AFROC) analysis was used to assess the overall performance of the diagnostic accuracy of these professional groups. The variation in performance between each group was measured using the analysis of variance (ANOVA) test, to identify any statistical significant differences in the performance in interpretation between these groups. The relationship between the participants' perceived image interpretation accuracy during clinical practice and the actual accuracy of their image test bank score was examined using Pearson's Correlation Coefficient (r). Results: The results revealed that the radiographers gained the highest mean test bank score (28.5/40; 71%). This score was statistically higher than the mean test bank scores attained by the participating nurse practitioners (21/40; 53%) and casualty officers (21.5/40; 54%), with p < 0.01 and p = 0.02, respectively. When compared with each other, the scores from these latter groups showed no significant difference (p = 0.91). The mean 'area under the curve' (AUC) value achieved by the radiographers was also significantly higher (p < 0.01) in comparison to the AUC values demonstrated by the nurse practitioners and casualty officers, whose results, when compared, showed no significant

  9. Design and evaluation of learning strategies for a group of radiographers in radiostereometric analysis (RSA).

    Science.gov (United States)

    Muharemovic, O; Troelsen, A; Thomsen, M G; Kallemose, T; Gosvig, K K

    2017-11-01

    The purpose of this study was to design and evaluate a radiostereometric analysis (RSA) program aimed at radiographers in order to increase their cognitive and practical skills, thereby increasing image quality and minimizing exposure repetition. Twenty radiographers were randomized into two identically sized study groups. Training consisted of a theoretical and practical workshop using a phantom. Tests were performed to compare the effect of training to nontraining, and the effect of time duration on the maintenance of RSA skills. The effect of training was measured by a written test and three defined parameters influencing image quality. Group A reduced significantly (p RSA X-ray training program where radiographers significantly improve their theoretical and practical skills in centering the CP closer to the CCF, NB and RP. A duration of up to two months after training does not influence the quality of participants' performance. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  10. Midterm Clinical and Radiographic Results of Mobile-Bearing Revision Total Knee Arthroplasty.

    Science.gov (United States)

    Kim, Raymond H; Martin, J Ryan; Dennis, Douglas A; Yang, Charlie C; Jennings, Jason M; Lee, Gwo-Chin

    2017-06-01

    Constrained implants are frequently required in revision total knee arthroplasty (TKA) and are associated with an increase in aseptic component loosening and damage or wear to the constraining mechanisms, compared with primary TKA. The purpose of the following study was to evaluate the midterm clinical and radiographic results including the incidence of bearing complications in a group of patients undergoing revision TKA using mobile-bearing revision TKA implants. We retrospectively reviewed 316 consecutive mobile-bearing revision TKAs performed at 2 centers between 2006 and 2010. There were 183 women and 133 men with a mean age of 66 years. The patients were evaluated clinically using the Knee Society scores. A radiographic analysis was performed. Bearing specific complications (ie, instability or dislocation) were recorded. Patients were followed-up for a minimum of 24 months and a median of 59.88 months (range 24-121.2). The average Knee Society knee score and function scores increased from 40.8 and 47.9 points preoperatively to 80 points and 70.3 points, respectively (P bearing complications were observed. Revision TKA using mobile-bearing revision components demonstrated favorable midterm clinical and radiographic results with no occurrence of bearing instability or dislocation. Longer follow-up is required to evaluate for potential advantages of mobile-bearings over fixed-bearing revision components in terms of polyethylene wear reduction, reduced stress transmission across fixation interfaces, and reduced stress on the polyethylene post. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. PACS influence the radiographer's work

    International Nuclear Information System (INIS)

    Fridell, Kent; Aspelin, Peter; Edgren, Lars; Lindskoeld, Lars; Lundberg, Nina

    2009-01-01

    a new PACS technology and digital workflow. Using PACS technology, together with an adjustment to the new system workflow, the experience among radiographers was that the production of images increased and as a result the stress in work increased as well. Using PACS technology, medical staff had little control over the organization of image production and its workflow, so that radiographers experienced PACS as a more technical deterministic system allowing small human control in the organization of work.

  12. Thin-plate spline (TPS) graphical analysis of the mandible on cephalometric radiographs.

    Science.gov (United States)

    Chang, H P; Liu, P H; Chang, H F; Chang, C H

    2002-03-01

    We describe two cases of Class III malocclusion with and without orthodontic treatment. A thin-plate spline (TPS) analysis of lateral cephalometric radiographs was used to visualize transformations of the mandible. The actual sites of mandibular skeletal change are not detectable with conventional cephalometric analysis. These case analyses indicate that specific patterns of mandibular transformation are associated with Class III malocclusion with or without orthopaedic therapy, and visualization of these deformations is feasible using TPS graphical analysis.

  13. Correlation between radiographic analysis of alveolar bone density around dental implant and resonance frequency of dental implant

    Science.gov (United States)

    Prawoko, S. S.; Nelwan, L. C.; Odang, R. W.; Kusdhany, L. S.

    2017-08-01

    The histomorphometric test is the gold standard for dental implant stability quantification; however, it is invasive, and therefore, it is inapplicable to clinical patients. Consequently, accurate and objective alternative methods are required. Resonance frequency analysis (RFA) and digital radiographic analysis are noninvasive methods with excellent objectivity and reproducibility. To analyze the correlation between the radiographic analysis of alveolar bone density around a dental implant and the resonance frequency of the dental implant. Digital radiographic images for 35 samples were obtained, and the resonance frequency of the dental implant was acquired using Osstell ISQ immediately after dental implant placement and on third-month follow-up. The alveolar bone density around the dental implant was subsequently analyzed using SIDEXIS-XG software. No significant correlation was reported between the alveolar bone density around the dental implant and the resonance frequency of the dental implant (r = -0.102 at baseline, r = 0.146 at follow-up, p > 0.05). However, the alveolar bone density and resonance frequency showed a significant difference throughout the healing period (p = 0.005 and p = 0.000, respectively). Conclusion: Digital dental radiographs and Osstell ISQ showed excellent objectivity and reproducibility in quantifying dental implant stability. Nonetheless, no significant correlation was observed between the results obtained using these two methods.

  14. Radiographic analysis of the course of Legionella pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Lo, C.D.; MacKeen, A.D.; Campbell, D.R.; Fraser, D.B.; Marrie, T.J. (Dalhousie Univ., Halifax, Nova Scotia (Canada))

    1983-06-01

    The radiographic findings in the acute phase of Legionella pneumonia are generally non-specific and have been previously documented. A retrospective assessment of 12 patients with this bacterial pneumonia revealed that resolution of the radiographic findings was prolonged in five. The predominant feature in such patients is the transient finding of interstitial consolidation following the air-space consolidation, not unlike that of Mycoplasma or viral pneumonia. Eventual return to normal was evident in three patients and residual parenchymal fibrosis was noted in two patients.

  15. Radiographic analysis of the course of Legionella pneumonia

    International Nuclear Information System (INIS)

    Lo, C.D.; MacKeen, A.D.; Campbell, D.R.; Fraser, D.B.; Marrie, T.J.

    1983-01-01

    The radiographic findings in the acute phase of Legionella pneumonia are generally non-specific and have been previously documented. A retrospective assessment of 12 patients with this bacterial pneumonia revealed that resolution of the radiographic findings was prolonged in five. The predominant feature in such patients is the transient finding of interstitial consolidation following the air-space consolidation, not unlike that of Mycoplasma or viral pneumonia. Eventual return to normal was evident in three patients and residual parenchymal fibrosis was noted in two patients

  16. Radiographers and trainee radiologists reporting accident radiographs

    DEFF Research Database (Denmark)

    Buskov, L; Abild, A; Christensen, A

    2013-01-01

    To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital....

  17. Design and evaluation of learning strategies for a group of radiographers in radiostereometric analysis (RSA)

    DEFF Research Database (Denmark)

    Muharemovic, O; Troelsen, A; Thomsen, M G

    2017-01-01

    INTRODUCTION: The purpose of this study was to design and evaluate a radiostereometric analysis (RSA) program aimed at radiographers in order to increase their cognitive and practical skills, thereby increasing image quality and minimizing exposure repetition. METHODS AND MATERIALS: Twenty...... radiographers were randomized into two identically sized study groups. Training consisted of a theoretical and practical workshop using a phantom. Tests were performed to compare the effect of training to nontraining, and the effect of time duration on the maintenance of RSA skills. The effect of training...... after training group B had experienced overall significant improvement on a par with group A. CONCLUSION: It is realistic to implement an RSA X-ray training program where radiographers significantly improve their theoretical and practical skills in centering the CP closer to the CCF, NB and RP...

  18. Reliability and accuracy analysis of a new semiautomatic radiographic measurement software in adult scoliosis.

    Science.gov (United States)

    Aubin, Carl-Eric; Bellefleur, Christian; Joncas, Julie; de Lanauze, Dominic; Kadoury, Samuel; Blanke, Kathy; Parent, Stefan; Labelle, Hubert

    2011-05-20

    Radiographic software measurement analysis in adult scoliosis. To assess the accuracy as well as the intra- and interobserver reliability of measuring different indices on preoperative adult scoliosis radiographs using a novel measurement software that includes a calibration procedure and semiautomatic features to facilitate the measurement process. Scoliosis requires a careful radiographic evaluation to assess the deformity. Manual and computer radiographic process measures have been studied extensively to determine the reliability and reproducibility in adolescent idiopathic scoliosis. Most studies rely on comparing given measurements, which are repeated by the same user or by an expert user. A given measure with a small intra- or interobserver error might be deemed as good repeatability, but all measurements might not be truly accurate because the ground-truth value is often unknown. Thorough accuracy assessment of radiographic measures is necessary to assess scoliotic deformities, compare these measures at different stages or to permit valid multicenter studies. Thirty-four sets of adult scoliosis digital radiographs were measured two times by three independent observers using a novel radiographic measurement software that includes semiautomatic features to facilitate the measurement process. Twenty different measures taken from the Spinal Deformity Study Group radiographic measurement manual were performed on the coronal and sagittal images. Intra- and intermeasurer reliability for each measure was assessed. The accuracy of the measurement software was also assessed using a physical spine model in six different scoliotic configurations as a true reference. The majority of the measures demonstrated good to excellent intra- and intermeasurer reliability, except for sacral obliquity. The standard variation of all the measures was very small: ≤ 4.2° for Cobb angles, ≤ 4.2° for the kyphosis, ≤ 5.7° for the lordosis, ≤ 3.9° for the pelvic angles, and

  19. AFROC analysis of reporting radiographer's performance in CT head interpretation

    International Nuclear Information System (INIS)

    Lockwood, P.; Piper, K.

    2015-01-01

    Aim: A preliminary small scale study to assess the diagnostic performance of a limited group of reporting radiographers and consultant radiologists in clinical practice undertaking computed tomography (CT) head interpretation. Method: A multiple reader multiple case (MRMC) alternative free response receiver operating characteristic (AFROC) methodology was applied. Utilising an image bank of 30 CT head examinations, with a 1:1 ratio of normal to abnormal cases. A reference standard was established by double reporting the original reports using two additional independent consultant radiologists with arbitration of discordance by the researcher. Twelve observers from six southern National Health Service (NHS) trusts were invited to participate. The results were compared for accuracy, agreement, sensitivity, specificity. Data analysis used AFROC and area under the curve (AUC) with standard error. Results: The reporting radiographers results demonstrated a mean sensitivity rate of 88.7% (95% CI 82.3–95.1%), specificity 95.6% (96% CI 90.1–100%) and accuracy of 92.2% (95% CI 89.3–95%). The consultant radiologists mean sensitivity rate was 83.35% (95% CI 80–86.7%), specificity 90% (95% CI 86.7–93.3%) and accuracy of 86.65% (95% CI 83.3–90%). Observer performance between the two groups was compared with AFROC, AUC, and standard error analysis (p = 0.94, SE 0.202). Conclusion: The findings of this research indicate that within a limited study, a small group of reporting radiographers demonstrated high levels of diagnostic accuracy in the interpretation of CT head examinations that was equivalent to a small selection of consultant radiologists. - Highlights: • We assessed reporting radiographers and consultant radiologists in a clinical setting. • This was a small scale retrospective multi-reader multi-case multi-site study. • AFROC used lesion-based decisions rather than case-based decisions. • Within a limited study the observed performance was high in

  20. Total elbow arthroplasty: a radiographic outcome study

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Xue Susan [University of Washington, Department of Radiology, Box 357115, Seattle, WA (United States); Petscavage-Thomas, Jonelle M. [Penn State Hershey Medical Center, Department of Radiology, Hershey, PA (United States); Ha, Alice S. [University of Washington, Department of Radiology, Box 354755, Seattle, WA (United States)

    2016-06-15

    Total elbow arthroplasty (TEA) is becoming a popular alternative to arthrodesis for patients with end-stage elbow arthrosis and comminuted distal humeral fractures. Prior outcome studies have primarily focused on surgical findings. Our purpose is to determine the radiographic outcome of TEA and to correlate with clinical symptoms such as pain. This is an IRB-approved retrospective review from 2005 to 2015 of all patients with semiconstrained TEA. All available elbow radiographs and clinical data were reviewed. Data analysis included descriptive statistics and Kaplan-Meier survival curves for radiographic and clinical survival. A total of 104 total elbow arthroplasties in 102 patients were reviewed; 75 % were in women and the mean patient age was 63.1 years. Mean radiographic follow-up was 826 days with average of four radiographs per patient. Seventy TEAs (67 %) developed radiographic complications, including heterotopic ossification (48 %), perihardware lucency (27 %), periprosthetic fracture (23 %), hardware subluxation/dislocation (7 %), polyethylene wear (3 %), and hardware fracture/dislodgement (3 %); 56 patients (55 %) developed symptoms of elbow pain or instability and 30 patients (30 %) underwent at least one reoperation. In patients with radiographic complications, 66 % developed elbow pain, compared to 19 % of patients with no radiologic complications (p = 0.001). Of the patients with radiographic complications, 39 % had at least one additional surgery compared to 0 % of patients without radiographic complications (p = 0.056). Radiographic complications are common in patients after total elbow arthroplasty. There is a strong positive association between post-operative radiographic findings and clinical outcome. Knowledge of common postoperative radiographic findings is important for the practicing radiologist. (orig.)

  1. Radiographic analysis in works of art - its utilization in the restoration, conservation and authentification

    International Nuclear Information System (INIS)

    Esteves, C.A.; Coelho, J.C.; Pereira, A.A.; Mendes, M.; Cunha, A.P.; Fernandes, L.E.A.P.V.; Menezes Freitas, A. de; Batista, A.C.N.

    1990-01-01

    The radiographic methods are important in the scientific inquiry of the art and archaelogic works throughout the world. In Brazil, this study has been realized at a few biological research groups and no more development can be recognized. By the radiographic analysis of six oils on canvas assigned to Ataide (Manuel da Costa Ataide), an impressionist painter of the 18th century, the authors try to determine his main technical pattern (distribution of heavy metal pigments, application of thick layers of pigment, etc.). The basic compositional elements were evaluated along with chemical tests and analysis by ultraviolet and infrared radiations, representing a historic document about Ataide's style. Each technique will be related to the purpose of the inquiry, affording the authors the opportunity to offer comments upon restoration, conservation and authentification of paintings. (author) [pt

  2. Radiographic analysis of temporomandibular joint arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    You, Dong Soo [Department of Oral Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1984-11-15

    The author analysed the bone changes, the positional relationships between condylar head and articular fossa, and the interrelationship between the bone changes and the abnormal position of condylar head, from 1,036 radiographs of 259 patients with temporomandibular joint arthrosis, which were obtained by the oblique-lateral transcranial projection and orthopantomograms. The results were as follows: 1. Among the radiographic bone changes of the temporomandibular joint arthrosis, deformity was 36..90% (217 cases), sclerosis 34.18% (201 cases), erosive change 25.58% (152 cases) and marginal proliferation 3.06% (18 cases) respectively. 2. In the positional changes between condylar head and articular fossa, the downward positioning of condylar head in centric occlusion was most frequent (36.90%), of which frequency was significantly higher than forward positioning (11.22%) and backward positioning (4.76%) in same condition. Also, radiographs showed that the enlargement of articular space showed higher frequency than its narrowing. In the opening position of mouth, the restrict ed movement of condylar head within articular fossa was most frequent (35.03%). The forward positioning and the downward positioning was 15.65% and 9.52% respectively. Also, radiographs revealed that the incomplete movement or no positional change of condylar head was most frequent. 3. In the interrelationship between bone changes and abnormal position of condylar head, deformity was 42.79% in the cases of downward positioning of condylar head in centric occlusion and 37.50% in those of normal positioning of condylar head in same condition. This revealed that deformity was most frequent bone change in above condylar positionings. However, erosive change was 34.62% in the cases of downward positioning of condylar head in centric occlusion and 33 .33% in those of forward positioning. In opening position of condylar head, and deformity in the cases of norma l positioning, forward positioning and

  3. Radiographic analysis of temporomandibular joint arthrosis

    International Nuclear Information System (INIS)

    You, Dong Soo

    1984-01-01

    The author analysed the bone changes, the positional relationships between condylar head and articular fossa, and the interrelationship between the bone changes and the abnormal position of condylar head, from 1,036 radiographs of 259 patients with temporomandibular joint arthrosis, which were obtained by the oblique-lateral transcranial projection and orthopantomograms. The results were as follows: 1. Among the radiographic bone changes of the temporomandibular joint arthrosis, deformity was 36..90% (217 cases), sclerosis 34.18% (201 cases), erosive change 25.58% (152 cases) and marginal proliferation 3.06% (18 cases) respectively. 2. In the positional changes between condylar head and articular fossa, the downward positioning of condylar head in centric occlusion was most frequent (36.90%), of which frequency was significantly higher than forward positioning (11.22%) and backward positioning (4.76%) in same condition. Also, radiographs showed that the enlargement of articular space showed higher frequency than its narrowing. In the opening position of mouth, the restrict ed movement of condylar head within articular fossa was most frequent (35.03%). The forward positioning and the downward positioning was 15.65% and 9.52% respectively. Also, radiographs revealed that the incomplete movement or no positional change of condylar head was most frequent. 3. In the interrelationship between bone changes and abnormal position of condylar head, deformity was 42.79% in the cases of downward positioning of condylar head in centric occlusion and 37.50% in those of normal positioning of condylar head in same condition. This revealed that deformity was most frequent bone change in above condylar positionings. However, erosive change was 34.62% in the cases of downward positioning of condylar head in centric occlusion and 33 .33% in those of forward positioning. In opening position of condylar head, and deformity in the cases of norma l positioning, forward positioning and

  4. Quantitative analysis of alveolar bone change following implant placement using intraoral radiographic subtraction

    International Nuclear Information System (INIS)

    Kimura, Hiroyuki; Kanda, Shigenobu; Tanaka, Takemasa

    2002-01-01

    The purpose of this study was to develop a procedure for quantitative analysis using intraoral radiographs of alveolar bone after placement of dental implants and to consider the validity of the method. We evaluated the ten patients (2 males and 8 females, average age: 48.4 years-old), who were treated with dental implant operation in the site of mandibular molar region, since October of 1999 until September of 2000 in Kimura Dental Clinic (Kumamoto, Japan). We evaluated the intraoral radiographs taken pre- and post- operatively and at follow-up examination. To detect alveolar bone change on radiograph, we adopted the digital subtraction method. Although the radiographs were taken under an ordinary technique with cone indicator, we did not apply the standardized technique with fixing material customized for each patient. Therefore, we used geometric correction and density compensation before subtraction. We assessed the basic statistical values (mean, variance, kurtosis and skewness) of the region of interest (ROI) of the subtracted images. Also, we noted PPD (probing pocket depth) and BOP (bleeding on probing) at each site as indicators of clinical findings and all implanted sites were classified according to the PPD or BOP, i.e. PPD increased group ''PPD (+)'' and PPD stable group ''PPD (-)'', likewise BOP positive group ''BOP (+)'' and negative group ''BOP (-)''. We considered the statistical values of ROI in each group and compared these findings. Mean and variance values of PPD (+) were higher than those of PPD (-) and there was a significant difference in mean value (p=0.031). Similarly, mean and variance values of BOP (+) were statistically higher than those of BOP (-) (p=0.041 and p=0.0087, respectively). Concerning kurtosis and skewness, there was no difference between PPD (+) and PPD (-), or between BOP (+) and BOP (-). Using our method, the radiographs taken for follow-up examination could be assessed quantitatively. It is suggested that geometric

  5. Value of radiographic examination of the knee joint for the orthopedic surgeon

    International Nuclear Information System (INIS)

    Pietsch, M.; Hofmann, S.

    2006-01-01

    Extended radiographic examinations offer excellent options for diagnosis and strategy for treatment of the knee joint. The whole-leg radiograph is indispensable in measuring alignment for osteotomy or total knee arthroplasty (TKA). Fluoroscopically assisted varus-valgus stress radiographs provide the possibility for verifying mechanical function of the implanted knee prosthesis. Ultrasound examinations have been widely replaced by magnetic resonance imaging (MRI). MRI is the golden standard to examine intra-articular structures of the knee (meniscus, ligaments, cartilage) and surrounding soft tissue. For evaluating femoral and tibial torsion and determining axial rotation of TKA, computed tomography (CT) is best qualified. Imaging of the patellofemoral joint (patella instability) is difficult; CT scans in combination with true lateral radiographs seem to be helpful. (orig.) [de

  6. Cauda equina syndrome in the dog: radiographic evaluation

    International Nuclear Information System (INIS)

    Morgan, J.P.; Bailey, C.S.

    1990-01-01

    Dogs with clinical signs typical of cauda equina syndrome require careful evaluation to determine the cause of the disease as this strongly influences choice of treatment. Possible aetiologies include congenital or developmental, inflammatory, traumatic, neoplastic, and degenerative lesions that may involve vertebrae, vertebral joints, intervertebral discs, spinal cord, spinal nerves, or meninges. It must be determined whether clinical signs are due to musculoskeletal or neurological disease before performing special radiographic procedures. Non-contrast radiography permits false-positive diagnosis of obvious degenerative changes involving the L-S disc that may be without clinical signs or permits a false-negative diagnosis due to the failure to appreciate soft tissue lesions not seen radiographically. Special radiographic techniques are recommended and include: (1) stress radiography, (2) discography, and (3) epidural myelography. Evaluation of the results of these studies assists in determining the cause of the cauda equina syndrome and the type of therapy required

  7. Quality of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    This chapter discussed on how to get a good radiograph. There are several factors that can make good radiograph such as density of radiograph, the contrast of radiograph, definition of radiograph, the present of artifact and backscattering. All of this factor will discuss detailed on each unit of chapter with some figure, picture to make the reader understand more when read this book. And at the end, the reader will introduce with penetrameter, one of device to determine the level of quality of the radiograph. There are two type of penetrameter like wire type or holes type. This standard must be followed by all the radiographer around the world to produce the good result that is standard and more reliable.

  8. Radiographic testing of wood

    International Nuclear Information System (INIS)

    Osterloh, K.; Zscherpel, U.; Raedel, C.; Weidemann, G.; Meinel, D.; Goebbels, J.; Ewert, U.; Hasenstab, A.; Buecherl, T.

    2007-01-01

    Wood is an old and established consumption and construction material. It is still the most common material for constructing furniture, roofs, playgrounds and mine supports. In contrast to steel and concrete, wood warns of extreme loads by creaking. Its mechanical stability is more influenced by decay than by peripheral cracks. While external cracks are visible, internal decay by fungus growth is undetectable from outside. This may be a safety problem in supporting structures. The best analysis of the internal structure is provided by computed tomography, but this is also the most complex method, much more so than simple radiographic testing. However, the latter is made inaccurate by scattered radiation resulting from internal moisture. With the image processing options of digital radiographic techniques, the structural information can be separated effectively from noise. In contrast to X-ray and gamma radiography, neutron radiography provides information on the spatial distribution of moisture. In healthy wood, water is conducted in the sapwood while the hardwood is dry. Moisture in hardwood is caused by infestations, e.g. fungus growth. The contribution presents a comparative analysis of the available radiographic methods. (orig.)

  9. Radiographic markers for measuring tibial rotation based on CT-reconstructed radiographs. An accuracy and feasibility study

    International Nuclear Information System (INIS)

    Hakimian, David; Khoury, Amal; Mosheiff, Rami; Liebergall, Meir; Weil, Yoram A.

    2018-01-01

    Malreduction in the axial plane (malrotation) following tibial fracture surgery is often undiagnosed. A few clinical and radiographic methods have been proposed for measuring tibial rotation intraoperatively, yet have failed to match the accuracy of computed tomography (CT). The aim of this study was to develop radiographic tools for future intraoperative assessment of the tibial shaft rotation profile. The setting was a laboratory computerized analysis. Twenty lower limb CT scans were used to construct a three-dimensional (3D) model using AMIRA copyright software. A virtual 3D cylinder was implanted in the posterior condylar line and in the transmalleolar axis. The 3D models were used to simulate four standard knee and ankle plain radiographs. On each radiograph, four landmarks were depicted by two observers and their relation with the cylinder was measured and analyzed for accuracy and reproducibility. A cadaveric lower leg was implanted with two Kirschner wires. A CT scan was performed in addition to 2D fluoroscopy. The simulated radiographs and the fluoroscopy were compared for accuracy. Measurement of the landmarks showed reliability in most of the knee anteroposterior and ankle mortise radiographs (coefficients of variation < 0.01 and = 0.01) respectively. Cadaveric measurement of the landmarks using real fluoroscopy and simulated radiographs were similar. To date, no reliable and common methods have been reported for the evaluation of tibial axial rotation. We propose a model in which simple radiographic landmarks can be used to calculate a 3D coordinate system that accurately assesses the axial rotation angle of the tibial shaft. (orig.)

  10. Radiographic markers for measuring tibial rotation based on CT-reconstructed radiographs. An accuracy and feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Hakimian, David; Khoury, Amal; Mosheiff, Rami; Liebergall, Meir; Weil, Yoram A. [Hadassah Hebrew University Hospital, Department of Orthopaedics, Jerusalem (Israel)

    2018-04-15

    Malreduction in the axial plane (malrotation) following tibial fracture surgery is often undiagnosed. A few clinical and radiographic methods have been proposed for measuring tibial rotation intraoperatively, yet have failed to match the accuracy of computed tomography (CT). The aim of this study was to develop radiographic tools for future intraoperative assessment of the tibial shaft rotation profile. The setting was a laboratory computerized analysis. Twenty lower limb CT scans were used to construct a three-dimensional (3D) model using AMIRA copyright software. A virtual 3D cylinder was implanted in the posterior condylar line and in the transmalleolar axis. The 3D models were used to simulate four standard knee and ankle plain radiographs. On each radiograph, four landmarks were depicted by two observers and their relation with the cylinder was measured and analyzed for accuracy and reproducibility. A cadaveric lower leg was implanted with two Kirschner wires. A CT scan was performed in addition to 2D fluoroscopy. The simulated radiographs and the fluoroscopy were compared for accuracy. Measurement of the landmarks showed reliability in most of the knee anteroposterior and ankle mortise radiographs (coefficients of variation < 0.01 and = 0.01) respectively. Cadaveric measurement of the landmarks using real fluoroscopy and simulated radiographs were similar. To date, no reliable and common methods have been reported for the evaluation of tibial axial rotation. We propose a model in which simple radiographic landmarks can be used to calculate a 3D coordinate system that accurately assesses the axial rotation angle of the tibial shaft. (orig.)

  11. Image analysis of bubble behavior in the pressurized fluidized bed using neutron radiograph

    International Nuclear Information System (INIS)

    Katoh, Yasuo; Miyamoto, Masahide; Miike, Hidetoshi; Kishimoto, Yasuyuki; Matsubayasi, Masahito; Mochiki, Kouichi.

    1996-01-01

    It is very important to know about the formation for bubble production growth and destruction. Because blowing gas nozzle decide the ability of the solid-gas fluidized bed system. For the pressurized 3-D fluidized bed, it was some interested in the bubble production and configuration which was taken place the interaction between bubble and particle under the pressurized condition. For the understanding of the three dimensional characteristics of production bubble under pressurized condition, the study of visualization of neutron radiograph seemed to be useful. In stead of typical X-ray visualization method, visualization of neutron radiograph method for observation of bubble behavior were carried out. Then an image analysis of it was done the same way as two dimension method P-system (PIAS-LA555WS Image Analysis). As the results, the characteristic of production bubble was more clear quantitatively, for example, the bubble production frequency, the bubble diameter and the bubble horizontal and vertical sizes so on. (author)

  12. Radiographic analysis of the development of the pelvic limb of captive-reared cranes (Grus spp.)

    International Nuclear Information System (INIS)

    Curro, T.G.; Langenberg, J.A.; Deakin, L.

    1996-01-01

    For captive-reared cranes, pelvic limb abnormalities in chicks have been identified as significant morbidity/mortality factors. An important component of the diagnosis of limb abnormalities is the understanding of the normal limb. This study was undertaken to describe the normal, radiographic development of the femur, tibiotarsus, tarsometatarsus, and fibula of the whooping crane (Grus americana), Florida sandhill crane (Grus canadensis pratensis), and Siberian crane (Grus leucogeranus). Crane chicks were anesthetized and their pelvic limb bone development evaluated radiographically on a weekly to bimonthly basis from one to fourteen weeks of age. Body weight, bone length, diaphyseal width, and physeal development and closure were evaluated. Based on the radiographic analysis, the gross development of the long bones of the pelvic limb of whooping, Florida sandhill, and Siberian cranes was found to be similar among the three species, and not dissimilar from other avian species which have been studied. Repeated handling, anesthesia, and radiographic exposure did not produce any behavioral, developmental, or physical abnormalities in the studied cranes when compared to cranes of the same species raised using the same methods. This is the first work to describe pelvic limb bone development in these species

  13. Radiographic and tomographic study of the elbow joint in dogs

    International Nuclear Information System (INIS)

    Sendyk-Grunkraut, Alessandra; Martin, Claudia M.; Souza, Alexandre N.A.; Patricio, Geni Cristina F.; Lorigados, Carla A.B.; Matera, Julia M.; Fonseca-Pinto, Ana C.B.C.

    2017-01-01

    Elbow dysplasia disease includes an united anconeal process, fragmented medial coronoid process, osteochondrosis of humeral trochlea, articular incongruity and degenerative joint disease. The aim of this study was to present detailed morphologic and morphometric aspects of the elbow joint in dog in clinical and correlate with radiographic and tomographic (CT) exam. Inter-observer variation for articular incongruity measurements by CT, comparative analysis in the radiographic exam, angle in ulnar notch and its comparative analysis between radiographic and tomographic agreement examination in 44 elbow of dogs with different ages were evaluated. The statistics analyses included the kappa coefficient and interclass correlation and Fischer's test and McNemar's test. It was evidenced that individual performance of each radiographic incidence had poor agreement with the tomographic exam, suggesting that the accomplishment of more than two radiograph views are needed. There was no agreement between the three evaluators in the ulnar notch angle at radiographic and tomographic exams. However, there was good/moderate agreement for articular incongruity measurement in the sagittal plane between evaluators. It was possible to conclude that none of the five radiographic incidences was better than the others for radiographic analysis because each incidence had a better identification of a particular elbow compartment; measurements at the tomographic exam to evaluate radioulnar incongruity had no reproductiveness in the frontal plane, but in sagittal plan had a good/moderate agreement between observers and the angle in ulnar notch presented no repeatability at radiographic exam and no reproductiveness at tomographic exam. (author)

  14. Radiographic analysis of ameloblastoma: A retrospective study

    Directory of Open Access Journals (Sweden)

    Chandramani More

    2012-01-01

    Conclusion: Radiographs are an important aid for the diagnosis of oral lesions of various types, especially those that involve bone. It is important for the practicing clinicians to know the salient features of ameloblastoma which are peculiar to the local population.

  15. Development and testing of texture discriminators for the analysis of trabecular bone in proximal femur radiographs

    International Nuclear Information System (INIS)

    Huber, M. B.; Carballido-Gamio, J.; Fritscher, K.; Schubert, R.; Haenni, M.; Hengg, C.; Majumdar, S.; Link, T. M.

    2009-01-01

    Purpose: Texture analysis of femur radiographs may serve as a potential low cost technique to predict osteoporotic fracture risk and has received considerable attention in the past years. A further application of this technique may be the measurement of the quality of specific bone compartments to provide useful information for treatment of bone fractures. Two challenges of texture analysis are the selection of the best suitable texture measure and reproducible placement of regions of interest (ROIs). The goal of this in vitro study was to automatically place ROIs in radiographs of proximal femur specimens and to calculate correlations between various different texture analysis methods and the femurs' anchorage strength. Methods: Radiographs were obtained from 14 femoral specimens and bone mineral density (BMD) was measured in the femoral neck. Biomechanical testing was performed to assess the anchorage strength in terms of failure load, breakaway torque, and number of cycles. Images were segmented using a framework that is based on the usage of level sets and statistical in-shape models. Five ROIs were automatically placed in the head, upper and lower neck, trochanteric, and shaft compartment in an atlas subject. All other subjects were registered rigidly, affinely, and nonlinearly, and the resulting transformation was used to map the five ROIs onto the individual femora. Results: In each ROI, texture features were extracted using gray level co-occurence matrices (GLCM), third-order GLCM, morphological gradients (MGs), Minkowski dimensions (MDs), Minkowski functionals (MFs), Gaussian Markov random fields, and scaling index method (SIM). Coefficients of determination for each texture feature with parameters of anchorage strength were computed. In a stepwise multiregression analysis, the most predictive parameters were identified in different models. Texture features were highly correlated with anchorage strength estimated by the failure load of up to R 2 =0.61 (MF

  16. Normal left ventricular emptying in coronary artery disease at rest: analysis by radiographic and equilibrium radionuclide ventriculography

    International Nuclear Information System (INIS)

    Denenberg, B.S.; Makler, P.T.; Bove, A.A.; Spann, J.F.

    1981-01-01

    The volume ejected early in systole has been proposed as an indicator of abnormal left ventricular function that is present at rest in patients with coronary artery disease with a normal ejection fraction and normal wall motion. The volume ejected in systole was examined by calculating the percent change in ventricular volume using both computer-assisted analysis of biplane radiographic ventriculograms at 60 frames/s and equilibrium gated radionuclide ventriculograms. Ventricular emptying was examined with radiographic ventriculography in 33 normal patients and 23 patients with coronary artery disease and normal ejection fraction. Eight normal subjects and six patients with coronary artery disease had both radiographic ventriculography and equilibrium gated radionuclide ventriculography. In all patients, there was excellent correlation between the radiographic and radionuclide ventricular emptying curves (r . 0.971). There were no difference in the ventricular emptying curves of normal subjects and patients with coronary artery disease whether volumes were measured by radiographic or equilibrium gated radionuclide ventriculography. It is concluded that the resting ventricular emptying curves are identical in normal subjects and patients with coronary artery disease who have a normal ejection fraction and normal wall motion

  17. An exploratory study of radiographer's perceptions of radiographer commenting on musculo-skeletal trauma images in rural community based hospitals

    International Nuclear Information System (INIS)

    Howard, Morag L.

    2013-01-01

    Aim: This study sought to explore the perceptions of community hospital based radiographers in North East Scotland regarding the practice of radiographer commenting on musculo-skeletal trauma images. Method: A purposive sample of radiographers (n = 8) were recruited from community hospitals throughout the North-east of Scotland. A qualitative, exploratory study was conducted employing semi-structured interviews consisting of one focus group and two individual interviews. The interviews were audio recorded and transcribed in full to allow thematic analysis of the data using a framework adapted from Pope and Mays (2006). Main findings: This study revealed that the practice of radiographer commenting in the community provides a valuable front line opinion on musculo-skeletal trauma image appearances to enhance diagnostic outcomes for patients and streamline their care pathway. The appreciation shown from inter-professional colleagues for this practice induced feelings of professional pride and job satisfaction in the sample group. All participants expressed a desire to undertake additional training to allow progression from radiographer commenting to radiographer reporting of musculo-skeletal trauma images. Perceived barriers to the practice of radiographer commenting were time constraints and a lack of support with regards to continuing professional development (CPD) opportunities and mentorship from radiology colleagues. Conclusion: The practice of radiographer commenting in the community setting should be supported by ongoing training, and radiologist involvement in mentoring could provide radiographers with a valuable support mechanism. The voice of all radiographers regarding this extended role must be heard by professional leaders to ensure that the skills and education required for radiographer commenting are provided and subsequent patient care is not compromised

  18. Congenital lumbar spinal stenosis: a prospective, control-matched, cohort radiographic analysis.

    Science.gov (United States)

    Singh, Kern; Samartzis, Dino; Vaccaro, Alexander R; Nassr, Ahmad; Andersson, Gunnar B; Yoon, S Tim; Phillips, Frank M; Goldberg, Edward J; An, Howard S

    2005-01-01

    Degenerative lumbar spinal stenosis manifests primarily after the sixth decade of life as a result of facet hypertrophy and degenerative disc disease. Congenital stenosis, on the other hand, presents earlier in age with similar clinical findings but with multilevel involvement and fewer degenerative changes. These patients may have subtle anatomic variations of the lumbar spine that may increase the likelihood of thecal sac compression. However, to the authors' knowledge, no quantitative studies have addressed various radiographic parameters of symptomatic, congenitally stenotic individuals to normal subjects. To radiographically quantify and compare the anatomy of the lumbar spine in symptomatic, congenitally stenotic individuals to age- and sex-matched, asymptomatic, nonstenotic controlled individuals. A prospective, control-matched, cohort radiographic analysis. Axial and sagittal magnetic resonance imaging (MRI) and lateral, lumbar, plain radiographs of 20 surgically treated patients who were given a clinical diagnosis of congenital lumbar stenosis by the senior author were randomized with images of 20, asymptomatic age- and sex-matched subjects. MRIs and lateral, lumbar, plain radiographs were independently quantitatively assessed by two individuals. Measurements obtained from the axial MRIs included: midline anterior-posterior (AP) vertebral body diameter, vertebral body width, midline AP canal diameter, canal width, spinal canal cross-sectional area, pedicle length, and pedicle width. From the sagittal MRIs, the following measurements were calculated: AP vertebral body diameter, vertebral body height, and AP canal diameter at the mid-vertebral level. On the lateral, lumbar, plain radiograph (L3 level), the AP diameters of the vertebral body spinal canal were measured. The images of these 40 individuals were then randomized and distributed in a blinded fashion to five separate spine surgeons who graded the presence and severity of congenital stenosis

  19. Radiographer interpretation of trauma radiographs: Issues for radiography education providers

    International Nuclear Information System (INIS)

    Hardy, Maryann; Snaith, Beverly

    2009-01-01

    Background: The role of radiographers with respect to image interpretation within clinical practice is well recognised. It is the expectation of the professional, regulatory and academic bodies that upon qualification, radiographers will possess image interpretation skills. Additionally, The College of Radiographers has asserted that its aspiration is for all radiographers to be able to provide an immediate written interpretation on skeletal trauma radiographs by 2010. This paper explores the readiness of radiography education programmes in the UK to deliver this expectation. Method: A postal questionnaire was distributed to 25 Higher Education Institutions in the UK (including Northern Ireland) that provided pre-registration radiography education as identified from the Society and College of Radiographers register. Information was sought relating to the type of image interpretation education delivered at pre- and post-registration levels; the anatomical range of image interpretation education; and education delivery styles. Results: A total of 19 responses (n = 19/25; 76.0%) were received. Image interpretation education was included as part of all radiographer pre-registration programmes and offered at post-registration level at 12 academic centres (n = 12/19; 63.2%). The anatomical areas and educational delivery methods varied across institutions. Conclusion: Radiography education providers have embraced the need for image interpretation education within both pre- and post-registration radiography programmes. As a result, UK education programmes are able to meet the 2010 College of Radiographers aspiration.

  20. New view on the initial development site and radiographic classification system of osteoarthritis of the knee based on radiographic analysis.

    Science.gov (United States)

    Moon, Ki-Ho

    2012-12-01

    Radiographic pathology of severe osteoarthritis of the knee (OAK) such as severe osteophyte at tibial spine (TS), compartment narrowing, marginal osteophyte, and subchondral sclerosis is well known. Kellgren-Lawrence grading system, which is widely used to diagnose OAK, describes narrowing-marginal osteophyte in 4-grades but uses osteophyte at TS only as evidence of OAK without detailed-grading. However, kinematically the knee employs medial TS as an axis while medial and lateral compartments carry the load, suggesting that early OAK would occur sooner at TS than at compartment. Then, Kellgren-Lawrence system may be inadequate to diagnose early-stage OAK manifested as a subtle osteophyte at TS without narrowing-marginal osteophyte. This undiagnosed-OAK will deteriorate becoming a contributing factor in an increasing incidence of OAK. This study developed a radiographic OAK-marker based on both osteophyte at TS and compartment narrowing-marginal osteophyte and graded as normal, mild, moderate, and severe. With this marker, both knee radiographs of 1,728 patients with knee pain were analyzed. Among 611 early-stage mild OAK, 562 or 92% started at TS and 49 or 8% at compartment. It suggests the initial development site of OAK, helping develop new site-specific radiographic classification system of OAK accurately to diagnose all severity of OAK at early, intermediate, or late-stage. It showed that Kellgren-Lawrence system missed 92.0% of early-stage mild OAK from diagnosis. A subtle osteophyte at TS is the earliest radiographic sign of OAK. A new radiographic classification system of OAK was suggested for accurate diagnosis of all OAK in severity and at stage.

  1. Computed tomography of stress fracture

    International Nuclear Information System (INIS)

    Murcia, M.; Brennan, R.E.; Edeiken, J.

    1982-01-01

    An athletic young female developed gradual onset of pain in the right leg. Plain radiographs demonstrated solid periosteal reaction in the tibia compatible with stress fracture. She stopped sport activites but her pain continued. Follow-up radiographs of the tibia revealed changes suspicious for osteoid osteoma. Computed tomography (CT) scan demonstrated periosteal reaction, but in addition, lucent fracture lines in the tibial cortex were evident. CT obviated the need for more invasive diagnostic procedures in this patient. In selected cases CT may be useful to confirm the diagnosis of stress fracture when plain radiographic or routine tomographic studies are not diagnostic. (orig.)

  2. Computed tomography of stress fracture

    International Nuclear Information System (INIS)

    Murcia, M.; Brennan, R.E.; Edeiken, J.

    1982-01-01

    An athletic young female developed gradual onset of pain in the right leg. Plain radiographs demonstrated solid periosteal reaction in the tibia compatible with stress fracture. She stopped sport activites but her pain continued. Follow-up radiographs of the tibia revealed changes suspicious for osteoid osteoma. Computed tomography (CT) scan demonstrated periosteal reaction, but in addition, lucent fracture lines in the tibial cortex were evident. CT obviated the need for more invasive diagnostic procedures in this patient. In selected cases CT may be useful to confirm the diagnosis of stress fracture when plain radiographic or routine tomographic studies are not diagnostic

  3. Agreement between radiographic and photographic trabecular patterns

    Energy Technology Data Exchange (ETDEWEB)

    Korstjens, C.M.; Geraets, W.G.M.; Stelt, P.F. van der [Dept. of Oral Radiology, Academic Centre for Dentistry, Amsterdam (Netherlands); Spruijt, R.J. [Div. of Psychosocial Research and Epidemiology, Netherlands Cancer Inst., Amsterdam (Netherlands); Mosekilde, L. [Dept. of Cell Biology, Univ. of Aarhus (Denmark)

    1998-11-01

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach`s {alpha}>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  4. Agreement between radiographic and photographic trabecular patterns

    International Nuclear Information System (INIS)

    Korstjens, C.M.; Geraets, W.G.M.; Stelt, P.F. van der; Spruijt, R.J.; Mosekilde, L.

    1998-01-01

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach's α>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  5. Radiographic caries diagnosis and restorative treatment decision making

    International Nuclear Information System (INIS)

    Mileman, P.A.

    1985-01-01

    This thesis is concerned with a single diagnostic technique: the bitewing radiograph, and the way it is used by dentists to decide on patient treatment need for interproximal caries. The variation in caries diagnosis and treatment decisions using bitewing radiographs is described and the radiographic criteria of choice for minimizing over and undertreatment according to a norm are investigated. Three possible diagnostic strategies in interproximal caries diagnosis using a decision analysis approach are described and evaluated, and the effect of the reported diagnostic behaviour and knowledge of practicing Dutch dentists in their use of bitewing radiographs for the diagnosis and treatment of interproximal caries is described and analyzed. (Auth.)

  6. Radiographical measurements for distal intra-articular fractures of the radius using plain radiographs and cone beam computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Suojaervi, Nora; Lindfors, N. [Helsinki University Central Hospital, Department of Hand Surgery, Helsinki (Finland); Sillat, T.; Koskinen, S.K. [HUS Helsinki Medical Imaging Center, Helsinki University Central Hospital, Department of Radiology, Helsinki (Finland)

    2015-12-15

    Operative treatment of an intra-articular distal radius fracture is one of the most common procedures in orthopedic and hand surgery. The intra- and interobserver agreement of common radiographical measurements of these fractures using cone beam computed tomography (CBCT) and plain radiographs were evaluated. Thirty-seven patients undergoing open reduction and volar fixation for a distal radius fracture were studied. Two radiologists analyzed the preoperative radiographs and CBCT images. Agreement of the measurements was subjected to intra-class correlation coefficient and the Bland-Altman analyses. Plain radiographs provided a slightly poorer level of agreement. For fracture diastasis, excellent intraobserver agreement was achieved for radiographs and good or excellent agreement for CBCT, compared to poor interobserver agreement (ICC 0.334) for radiographs and good interobserver agreement (ICC 0.621) for CBCT images. The Bland-Altman analyses indicated a small mean difference between the measurements but rather large variation using both imaging methods, especially in angular measurements. For most of the measurements, radiographs do well, and may be used in clinical practice. Two different measurements by the same reader or by two different readers can lead to different decisions, and therefore a standardization of the measurements is imperative. More detailed analysis of articular surface needs cross-sectional imaging modalities. (orig.)

  7. Radiographical measurements for distal intra-articular fractures of the radius using plain radiographs and cone beam computed tomography images.

    Science.gov (United States)

    Suojärvi, Nora; Sillat, T; Lindfors, N; Koskinen, S K

    2015-12-01

    Operative treatment of an intra-articular distal radius fracture is one of the most common procedures in orthopedic and hand surgery. The intra- and interobserver agreement of common radiographical measurements of these fractures using cone beam computed tomography (CBCT) and plain radiographs were evaluated. Thirty-seven patients undergoing open reduction and volar fixation for a distal radius fracture were studied. Two radiologists analyzed the preoperative radiographs and CBCT images. Agreement of the measurements was subjected to intra-class correlation coefficient and the Bland-Altman analyses. Plain radiographs provided a slightly poorer level of agreement. For fracture diastasis, excellent intraobserver agreement was achieved for radiographs and good or excellent agreement for CBCT, compared to poor interobserver agreement (ICC 0.334) for radiographs and good interobserver agreement (ICC 0.621) for CBCT images. The Bland-Altman analyses indicated a small mean difference between the measurements but rather large variation using both imaging methods, especially in angular measurements. For most of the measurements, radiographs do well, and may be used in clinical practice. Two different measurements by the same reader or by two different readers can lead to different decisions, and therefore a standardization of the measurements is imperative. More detailed analysis of articular surface needs cross-sectional imaging modalities.

  8. Image rejects/retakes-radiographic challenges

    International Nuclear Information System (INIS)

    Waaler, D.; Hofmann, B.

    2010-01-01

    A general held position among radiological personnel prior to digitalisation was that the problem of image rejects/retakes should more or less vanish. However, rejects/retakes still impose several challenges within radiographic imaging; they occupy unnecessary resources, expose patients to unnecessary ionizing radiation and may also indicate suboptimal quality management. The latter is the main objective of this paper, which is based on a survey of international papers published both for screen/film and digital technology. The digital revolution in imaging seems to have reduced the percentage of image rejects/retakes from 10-15 to 3-5%. The major contribution to the decrease appears to be the dramatic reduction of incorrect exposures. At the same time, rejects/retakes due to lack of operator competence (positioning, etc.) are almost unchanged, or perhaps slightly increased (due to lack of proper technical competence, incorrect organ coding, etc.). However, the causes of rejects/retakes are in many cases defined and reported with reference to radiographers' subjective evaluations. Thus, unless radiographers share common views on image quality and acceptance criteria, objective measurements and assessments of reject/retake rates are challenging tasks. Interestingly, none of the investigated papers employs image quality parameters such as 'too much noise' as categories for rejects/retakes. Surprisingly, no reject/retake analysis seems yet to have been conducted for direct digital radiography departments. An increased percentage of rejects/retakes is related to 'digital skills' of radiographers and therefore points to areas for extended education and training. Furthermore, there is a need to investigate the inter subjectivity of radiographers' perception of, and attitude towards, both technical and clinical image quality criteria. Finally, there may be a need to validate whether reject/retake rate analysis is such an effective quality indicator as has been asserted

  9. Image rejects/retakes--radiographic challenges.

    Science.gov (United States)

    Waaler, D; Hofmann, B

    2010-01-01

    A general held position among radiological personnel prior to digitalisation was that the problem of image rejects/retakes should more or less vanish. However, rejects/retakes still impose several challenges within radiographic imaging; they occupy unnecessary resources, expose patients to unnecessary ionizing radiation and may also indicate suboptimal quality management. The latter is the main objective of this paper, which is based on a survey of international papers published both for screen/film and digital technology. The digital revolution in imaging seems to have reduced the percentage of image rejects/retakes from 10-15 to 3-5 %. The major contribution to the decrease appears to be the dramatic reduction of incorrect exposures. At the same time, rejects/retakes due to lack of operator competence (positioning, etc.) are almost unchanged, or perhaps slightly increased (due to lack of proper technical competence, incorrect organ coding, etc.). However, the causes of rejects/retakes are in many cases defined and reported with reference to radiographers' subjective evaluations. Thus, unless radiographers share common views on image quality and acceptance criteria, objective measurements and assessments of reject/retake rates are challenging tasks. Interestingly, none of the investigated papers employs image quality parameters such as 'too much noise' as categories for rejects/retakes. Surprisingly, no reject/retake analysis seems yet to have been conducted for direct digital radiography departments. An increased percentage of rejects/retakes is related to 'digital skills' of radiographers and therefore points to areas for extended education and training. Furthermore, there is a need to investigate the inter-subjectivity of radiographers' perception of, and attitude towards, both technical and clinical image quality criteria. Finally, there may be a need to validate whether reject/retake rate analysis is such an effective quality indicator as has been asserted.

  10. Analysis of fuel-bundle radiographs using modeling

    International Nuclear Information System (INIS)

    Demuth, H.B.

    1975-07-01

    It was desired to estimate the thickness of gaps imaged on highly degraded radiographs. A powerful mathematical method for estimating gap widths was developed and applied. The problem, the techniques used to solve the problem, and results, conclusions, and suggestions for future work are presented. (U.S.)

  11. The radiographic acromiohumeral interval is affected by arm and radiographic beam position

    Energy Technology Data Exchange (ETDEWEB)

    Fehringer, Edward V.; Rosipal, Charles E.; Rhodes, David A.; Lauder, Anthony J.; Feschuk, Connie A.; Mormino, Matthew A.; Hartigan, David E. [University of Nebraska Medical Center, Department of Orthopaedic Surgery and Rehabilitation, Omaha, NE (United States); Puumala, Susan E. [Nebraska Medical Center, Department of Preventive and Societal Medicine, Omaha, NE (United States)

    2008-06-15

    The objective was to determine whether arm and radiographic beam positional changes affect the acromiohumeral interval (AHI) in radiographs of healthy shoulders. Controlling for participant's height and position as well as radiographic beam height and angle, from 30 right shoulders of right-handed males without shoulder problems four antero-posterior (AP) radiographic views each were obtained in defined positions. Three independent, blinded physicians measured the AHI to the nearest millimeter in 120 randomized radiographs. Mean differences between measurements were calculated, along with a 95% confidence interval. Controlling for observer effect, there was a significant difference between AHI measurements on different views (p<0.01). All pair-wise differences were statistically significant after adjusting for multiple comparisons (all p values <0.01). Even in healthy shoulders, small changes in arm position and radiographic beam orientation affect the AHI in radiographs. (orig.)

  12. The effect of perceived organizational support on organizational commitment of diagnostic imaging radiographers

    International Nuclear Information System (INIS)

    Makanjee, Chandra Rekha; Hartzer, Yolanda F.; Uys, Ilse L.

    2006-01-01

    This article arises from a research project investigating the effects of occupational stress and organizational commitment of diagnostic imaging radiographers on rendering quality service. One of the main aims of this project was to determine the extent to which perceived organizational support influenced commitment of radiographers to the organization, to reduce turnover intent and quality of service rendered. A descriptive correlation study design, based on questionnaires completed by 119 radiographers from 11 organizations, revealed that organizational commitment was moderate towards a tendency of poor. A positive relationship was found between various antecedents of perceived organizational support and organizational commitment (mainly affective and normative), indicating that perceived organizational support positively influenced radiographers' organizational commitment. There is a clear indication of turnover intent, which in turn has a negative impact on rendering quality service. In conclusion, to reduce turnover intent, and improve quality of service rendered, management needs to play an important role in creating a positive working environment for radiographers to perform their tasks

  13. Accuracy of chest radiographs in the emergency diagnosis of heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Studler, Ueli; Kretzschmar, Martin; Steinbrich, Wolfgang [University Hospital Basel, Department of Radiology, Basel (Switzerland); Christ, Michael; Breidthardt, Tobias; Noveanu, Markus; Perruchoud, Andre P.; Mueller, Christian [University Hospital Basel, Department of Internal Medicine, Basel (Switzerland); Schoetzau, Andreas [Institute of Biostatistics, Basel (Switzerland)

    2008-08-15

    The purpose of this study was to determine the diagnostic accuracy of chest radiographic findings of heart failure (HF) in current patients presenting with dyspnea in the emergency department. In a secondary analysis of the BASEL study, initial chest radiographs of 277 patients with acute dyspnea were evaluated by two radiologists blinded to the adjudicated diagnosis (56% had the final diagnosis of HF). Predefined radiographic criteria of HF were used. Statistical analysis included receiver-operating characteristic (ROC) analysis and calculation of a logistic regression model including B-type natriuretic peptide (BNP) levels. The reader's overall impression showed the highest area under the ROC curve for the diagnosis of HF in both supine and erect patient positions (0.855 and 0.857). Among individual radiographic findings, peribronchial cuffing in the supine position (0.829) showed the highest accuracies. The lowest accuracy was found for the vascular pedicle width in the supine position (0.461). Logistic regression analysis showed no significant differences between the reader's overall impression, the radiographic model, and BNP testing. In our study, the combination of radiographic features provided valuable information and was of comparable accuracy as BNP-testing for the diagnosis of HF. (orig.)

  14. Fast radiographic systems

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1984-08-01

    Industrial radiography can be performed with shorter exposure times, when instead of X-ray film with lead intensifying screens the radiographic paper with fluorescent screen is used. With paper radiography one can obtain lower material, equipment, and labor costs, shorter exposure and processing times, and easier radiation protection. The speed of the radiographic inspection can also be increased by the use of fluorometallic intensifying screens together with a special brand of X-ray film. Before accepting either of the two fast radiographic systems one must be sure that they can produce radiographs of adequate image quality. Therefore an investigation was performed on that subject using ISO wire IQI's and ASTM penetrameters. The radiographic image quality was tested for aluminium and steel up to 30 mm thick using various brands of radiographic paper and X-ray film with fluorometallic screens and comparing them with fast X-ray films with lead screens. Both systems give satisfactory results. (author)

  15. Radiographically Occult and Subtle Fractures: A Pictorial Review

    International Nuclear Information System (INIS)

    Jarraya, M.; Hayashi, D.; Roemer, F.W.; Crema, M.D.; Conlin, J.; Marra, M.D.; Guermazi, A.; Roemer, F.W.; Crema, M.D.; Diaz, L.; Conlin, J.; Jomaah, N.

    2013-01-01

    Radiographically occult and subtle fractures are a diagnostic challenge. They may be divided into (1) high energy trauma fracture, (2) fatigue fracture from cyclical and sustained mechanical stress, and (3) insufficiency fracture occurring in weakened bone (e.g., in osteoporosis and post radiotherapy). Independently of the cause, the initial radiographic examination can be negative either because the findings seem normal or are too subtle. Early detection of these fractures is crucial to explain the patients symptoms and prevent further complications. Advanced imaging tools such as computed tomography, magnetic resonance imaging, and scintigraphy are highly valuable in this context. Our aim is to raise the awareness of radiologists and clinicians in these cases by presenting illustrative cases and a discussion of the relevant literature.

  16. Mycoplasma pneumonia in children: radiographic pattern analysis and difference in resolution

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Myeong Ja; Jeong, Sung Eun; Kim, Joung Sook; Hur, Gham; Park, Jeung Uk [Inje Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-11-01

    By analysing frequency and disease progression, this study aimed to investigate and predict the prognosis of mycoplasma pneumonia according to radiographic pattern. We retrospectively reviewed plain chest radiographs of 230 patients in whom mycoplasm pneumonia had been serologically confirmed. Their age ranged from two months to 14 years and two months, and 203(88.3%) were younger than eight years. Radiographic patterns were classified as air space consolidation, bronchopneumonic, interstitial pneumonic or diffuse mixed infiltrating type. The radiologic resolution period for each type was analysed by the resolution of symptoms and normalization of radiologic findings. The bronchopneumonic type, which was the most common, was seen in 82 patients(35.6%), airspace consolidation in 58(25.2%), interstitial in 55(23.9%), and diffuse mixed in 22(9.57%). In thirteen patients(5.7%), chest radiographs were normal, though the clinical and radiologic resolution period for each type was variable. The mean resolution period of the air space consolidation type was 14.5 days, bronchopneumonic, 7.6 days ; interstitial, 10.5 days, and diffuse mixed, 15.6 days. The airspace consolidation type needed the longest recovery period, exceeded only by the diffuse mixed type. The bronchopneumonic type was the most common radiographic pattern of mycoplasma pneumonia. The prognosis of the airspace consolidation type seems to be poorest, since this required the longest recovery period.

  17. Radiographic imaging. 4 ed.

    International Nuclear Information System (INIS)

    Chesney, D.N.; Chesney, M.O.

    1981-01-01

    This is a revised edition of the textbook previously entitled 'Radiographic Photography' and accords with the current syllabus of training for the Diploma of the Royal College of Radiographers. The aim is a non-mathematical approach to provide a guide for the student to the knowledge and understanding of the theoretical concepts which affect the quality of radiographic image; materials and practices are also reviewed, particularly in relation to the characteristics of the radiographic image, and to processing equipment and processing areas. The subject is dealt with under the following headings: the photographic process, film materials in x-ray departments, sensitometry, storage of film materials and radiographs, intensifying screens and cassettes, film processing, developing, fixing, rinsing, washing, drying, the processing area and equipment, systems for daylight film handling, the radiographic image, management of the quality, presentation of the radiograph, light images and their recording, fluorography, some special imaging processes, e.g. xerography, copying radiographs. (U.K.)

  18. Educational and experiential effects on radiographers' radiation safety behavior

    International Nuclear Information System (INIS)

    Tilson, E.R.

    1982-01-01

    Forty-four radiographers from 11 hospitals in Northern California were observed for radiation safety behaviors in six categories. A multiple regression analysis was performed to determine if there was a significant relationship between the six radiation safety behaviors and the radiographer's age, sex, type of professional training, years since completion of professional training, years of professional practice, time of day, and exposure frequency. The multiple regression analysis showed that there was a significant relationship between use of gonadal shielding and years since completion of professional training, years of professional practice, type of training, and age. The multiple regression analysis also showed that the number of repeated films due to technical error was significantly related to the type of professional training a radiographer received

  19. Development and testing of texture discriminators for the analysis of trabecular bone in proximal femur radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Huber, M. B.; Carballido-Gamio, J.; Fritscher, K.; Schubert, R.; Haenni, M.; Hengg, C.; Majumdar, S.; Link, T. M. [Department of Radiology and Biomedical Imaging, University of California, 400 Parnassus Avenue, San Francisco, California 94143 (United States); University of Health Sciences, Medical Informatics and Technology, 6060 Hall (Austria); AO Development Institute, 7270 Davos Platz (Switzerland); Medical University Innsbruck, 6020 Innsbruck (Austria); Department of Radiology and Biomedical Imaging, University of California, 400 Parnassus Avenue, San Francisco, California 94143 (United States)

    2009-11-15

    Purpose: Texture analysis of femur radiographs may serve as a potential low cost technique to predict osteoporotic fracture risk and has received considerable attention in the past years. A further application of this technique may be the measurement of the quality of specific bone compartments to provide useful information for treatment of bone fractures. Two challenges of texture analysis are the selection of the best suitable texture measure and reproducible placement of regions of interest (ROIs). The goal of this in vitro study was to automatically place ROIs in radiographs of proximal femur specimens and to calculate correlations between various different texture analysis methods and the femurs' anchorage strength. Methods: Radiographs were obtained from 14 femoral specimens and bone mineral density (BMD) was measured in the femoral neck. Biomechanical testing was performed to assess the anchorage strength in terms of failure load, breakaway torque, and number of cycles. Images were segmented using a framework that is based on the usage of level sets and statistical in-shape models. Five ROIs were automatically placed in the head, upper and lower neck, trochanteric, and shaft compartment in an atlas subject. All other subjects were registered rigidly, affinely, and nonlinearly, and the resulting transformation was used to map the five ROIs onto the individual femora. Results: In each ROI, texture features were extracted using gray level co-occurence matrices (GLCM), third-order GLCM, morphological gradients (MGs), Minkowski dimensions (MDs), Minkowski functionals (MFs), Gaussian Markov random fields, and scaling index method (SIM). Coefficients of determination for each texture feature with parameters of anchorage strength were computed. In a stepwise multiregression analysis, the most predictive parameters were identified in different models. Texture features were highly correlated with anchorage strength estimated by the failure load of up to R{sup 2

  20. Knee Images Digital Analysis (KIDA): a novel method to quantify individual radiographic features of knee osteoarthritis in detail.

    Science.gov (United States)

    Marijnissen, A C A; Vincken, K L; Vos, P A J M; Saris, D B F; Viergever, M A; Bijlsma, J W J; Bartels, L W; Lafeber, F P J G

    2008-02-01

    Radiography is still the golden standard for imaging features of osteoarthritis (OA), such as joint space narrowing, subchondral sclerosis, and osteophyte formation. Objective assessment, however, remains difficult. The goal of the present study was to evaluate a novel digital method to analyse standard knee radiographs. Standardized radiographs of 20 healthy and 55 OA knees were taken in general practise according to the semi-flexed method by Buckland-Wright. Joint Space Width (JSW), osteophyte area, subchondral bone density, joint angle, and tibial eminence height were measured as continuous variables using newly developed Knee Images Digital Analysis (KIDA) software on a standard PC. Two observers evaluated the radiographs twice, each on two different occasions. The observers were blinded to the source of the radiographs and to their previous measurements. Statistical analysis to compare measurements within and between observers was performed according to Bland and Altman. Correlations between KIDA data and Kellgren & Lawrence (K&L) grade were calculated and data of healthy knees were compared to those of OA knees. Intra- and inter-observer variations for measurement of JSW, subchondral bone density, osteophytes, tibial eminence, and joint angle were small. Significant correlations were found between KIDA parameters and K&L grade. Furthermore, significant differences were found between healthy and OA knees. In addition to JSW measurement, objective evaluation of osteophyte formation and subchondral bone density is possible on standard radiographs. The measured differences between OA and healthy individuals suggest that KIDA allows detection of changes in time, although sensitivity to change has to be demonstrated in long-term follow-up studies.

  1. Radiographic indices for lumbar developmental spinal stenosis

    Directory of Open Access Journals (Sweden)

    Jason Pui Yin Cheung

    2017-02-01

    Full Text Available Abstract Background Patients with developmental spinal stenosis (DSS are susceptible to developing symptomatic stenosis due to pre-existing narrowed spinal canals. DSS has been previously defined by MRI via the axial anteroposterior (AP bony spinal canal diameter. However, MRI is hardly a cost-efficient tool for screening patients. X-rays are superior due to its availability and cost, but currently, there is no definition of DSS based on plain radiographs. Thus, the aim of this study is to develop radiographic indices for diagnosing DSS. Methods This was a prospective cohort of 148 subjects consisting of patients undergoing surgery for lumbar spinal stenosis (patient group and asymptomatic subjects recruited openly from the general population (control group. Ethics approval was obtained from the local institutional review board. All subjects underwent MRI for diagnosing DSS and radiographs for measuring parameters used for creating the indices. All measurements were performed by two independent investigators, blinded to patient details. Intra- and interobserver reliability analyses were conducted, and only parameters with near perfect intraclass correlation underwent receiver operating characteristic (ROC analysis to determine the cutoff values for diagnosing DSS using radiographs. Results Imaging parameters from a total of 66 subjects from the patient group and 82 asymptomatic subjects in the control group were used for analysis. ROC analysis suggested sagittal vertebral body width to pedicle width ratio (SBW:PW as having the strongest sensitivity and specificity for diagnosing DSS. Cutoff indices for SBW:PW were level-specific: L1 (2.0, L2 (2.0, L3 (2.2, L4 (2.2, L5 (2.5, and S1 (2.8. Conclusions This is the first study to define DSS on plain radiographs based on comparisons between a clinically relevant patient group and a control group. Individuals with DSS can be identified by a simple radiograph using a screening tool allowing for better

  2. Main factors of efficiency of automated radiographic complex

    International Nuclear Information System (INIS)

    Akopov, V.S.; Voronin, S.A.; Grachev, A.V.; Golenishchev, I.A.; Majorov, A.N.; Meshalkin, I.A.

    1978-01-01

    The amount of work providing an assessment of the efficiency of a complex for automatized radiographic control is considered. The technique involves four stages. An analysis was performed to ascertain the efficiency of control of flaw detectability with regard to each of the stages of radiographic control. The relationships used in determining control efficiency and cited in the paper serve as a foundation for optimizing the technical parameters of the devices of the automatized complex and for creating calculation methods for generalized assessments of the efficiency of radiographic control

  3. Basal cell naevus syndrome - radiographic findings in the skull

    Energy Technology Data Exchange (ETDEWEB)

    Stoll, P.; Dueker, J.; Weingart, D.

    1986-09-01

    Besides uni- and multiocular jaw cysts the Gorlin Goltz syndrome shows other characteristic radiographic findings which help to ensure diagnosis. These are particularly calcification of the falx cerebri and a so called ''bridging'' between processus clinoideus anterior and posterior of the sella turcica. The importance of early diagnosis is stressed.

  4. The radiographer-patient relationship: Enhancing understanding using a transactional analysis approach

    International Nuclear Information System (INIS)

    Booth, Lisa

    2008-01-01

    Purpose: Government initiatives such as the NHS Plan, the NHS Key Skills Framework and the NHS Career framework place communication at the centre of effective patient care, and role/career development. All advocate a patient-centred approach to dealing with patients, through open communication styles that encourage patients to become active participants in their care. Previous research, that has investigated communication in diagnostic radiography, demonstrated a preference for practitioner-centred, rather than patient-centred approaches to communication, however, there is little evidence to suggest why this should be the case or how a more patient-centred approach might be encouraged. The present study therefore sought to explore factors that influence communication in diagnostic radiography, with the view to understanding the barriers to patient-centred care. Method: Semi-structured group interviews took place with 12 radiographers, across two NHS trusts, with the aim of understanding their communication with patients and the factors that influence it. An open coding approach was used to analyse the data. Results: Four attitude categories were identified as influencing the communication used by diagnostic radiographers. 1. Characteristics of the radiographer. 2. Characteristics of the patient. 3. The need to produce a diagnostic image. 4. The need to keep the department running. Conclusion: Radiographer-patient communication is evidently influenced by these four attitude categories. If patient-centred styles of communication are to be encouraged, these factors need to be recognised and taken account of in the selection, education/training and workforce planning of diagnostic radiographers

  5. A radiographic study of mental foramen in intraoral radiographs

    International Nuclear Information System (INIS)

    Sohn, Jeong Ick; Choi, Karp Shik

    1995-01-01

    The purpose of this study was to evaluate the position and shape of mental foramen in periapical radiographs. For this study, periapical radiographs of premolar areas were obtained from the 200 adults. Accordingly, the positional and shape changes of mental foramen were evaluated. The authors obtained radiographs according to changes in radiation beam direction in periapical radiographs of premolar areas, and then evaluated the positional and shape changes of mental foramen. The following results were obtained: 1. Shapes of mental foramen were observed elliptical (34.3%), round or oval (28.0%), unidentified (25.5%) and diffuse (12.2%) type in descending order of frequency. 2, Horizontal positions of mental foramen were most frequently observed at the 2nd premolar area (55.3%), the area between the 1st premolar and 2nd premolar (39.6%), the area between the 2nd premolar and 1st molar (3.4%), the 1st premolar area (1.0%), the area between the canine and 1st premolar (0.7%) in descending order of frequency. 3. Vertical positions of mental foramen were most frequently observed at the inferior to apex (67.1%), and at apex (24.8%), overlap with apex (6.4%), superior to apex (1.7%) in descending order of frequency. 4. Shapes of mental foramen were more obviously observed at the upward 10 degree positioned periapical radiographs. And according to the changes of horizontal and vertical position, they were observed similar to normally positioned periapical radiographs.

  6. Relationships between rotator cuff tear types and radiographic abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soo Hyun; Chun, Kyung Ah; Lee Soo Jung; Kang, Min Ho; Yi, Kyung Sik; Zhang, Ying [Dept. of Diagnostic Radiology, College of Medicine, Chungbuk National University, Cheongju (Korea, Republic of)

    2014-11-15

    To determine relationships between different types of rotator cuff tears and radiographic abnormalities. The shoulder radiographs of 104 patients with an arthroscopically proven rotator cuff tear were compared with similar radiographs of 54 age-matched controls with intact cuffs. Two radiologists independently interpreted all radiographs for; cortical thickening with subcortical sclerosis, subcortical cysts, osteophytes in the humeral greater tuberosity, humeral migration, degenerations of the acromioclavicular and glenohumeral joints, and subacromial spurs. Statistical analysis was performed to determine relationships between each type of rotator cuff tears and radiographic abnormalities. Inter-observer agreements with respect to radiographic findings were analyzed. Humeral migration and degenerative change of the greater tuberosity, including sclerosis, subcortical cysts, and osteophytes, were more associated with full-thickness tears (p < 0.01). Subacromial spurs were more common for full-thickness and bursal-sided tears (p < 0.01). No association was found between degeneration of the acromioclavicular or glenohumeral joint and the presence of a cuff tear. Different types of rotator cuff tears are associated with different radiographic abnormalities.

  7. Relationships between rotator cuff tear types and radiographic abnormalities

    International Nuclear Information System (INIS)

    Lee, Soo Hyun; Chun, Kyung Ah; Lee Soo Jung; Kang, Min Ho; Yi, Kyung Sik; Zhang, Ying

    2014-01-01

    To determine relationships between different types of rotator cuff tears and radiographic abnormalities. The shoulder radiographs of 104 patients with an arthroscopically proven rotator cuff tear were compared with similar radiographs of 54 age-matched controls with intact cuffs. Two radiologists independently interpreted all radiographs for; cortical thickening with subcortical sclerosis, subcortical cysts, osteophytes in the humeral greater tuberosity, humeral migration, degenerations of the acromioclavicular and glenohumeral joints, and subacromial spurs. Statistical analysis was performed to determine relationships between each type of rotator cuff tears and radiographic abnormalities. Inter-observer agreements with respect to radiographic findings were analyzed. Humeral migration and degenerative change of the greater tuberosity, including sclerosis, subcortical cysts, and osteophytes, were more associated with full-thickness tears (p < 0.01). Subacromial spurs were more common for full-thickness and bursal-sided tears (p < 0.01). No association was found between degeneration of the acromioclavicular or glenohumeral joint and the presence of a cuff tear. Different types of rotator cuff tears are associated with different radiographic abnormalities.

  8. The ``gray cortex``: an early sign of stress fracture

    Energy Technology Data Exchange (ETDEWEB)

    Mulligan, M.E. [Dept. of Radiology, Univ. of Maryland Medical Center, Baltimore, MD (United States)

    1995-04-01

    The purpose of this report is to describe an early radiographic sign of stress fracture, the ``gray cortex.`` The imaging findings in three patients with tibial stress fractures were reviewed. The ``gray cortex`` sign was evident on the initial conventional radiographs in all three cases. It was prospectively reported as a sign of stress fracture in two patients and was evident on the initial radiographs (taken elsewhere) of the third patient, who was referred for additional workup of a possible neoplasm. Special imaging studies (technetium-99m bone scan, computed tomography, and magnetic resonance imaging) confirmed the diagnosis in all three cases. (orig.)

  9. The ''gray cortex'': an early sign of stress fracture

    International Nuclear Information System (INIS)

    Mulligan, M.E.

    1995-01-01

    The purpose of this report is to describe an early radiographic sign of stress fracture, the ''gray cortex.'' The imaging findings in three patients with tibial stress fractures were reviewed. The ''gray cortex'' sign was evident on the initial conventional radiographs in all three cases. It was prospectively reported as a sign of stress fracture in two patients and was evident on the initial radiographs (taken elsewhere) of the third patient, who was referred for additional workup of a possible neoplasm. Special imaging studies (technetium-99m bone scan, computed tomography, and magnetic resonance imaging) confirmed the diagnosis in all three cases. (orig.)

  10. Defects quantization in industrial radiographs by image processing

    International Nuclear Information System (INIS)

    Briand, F.Y.; Brillault, B.; Philipp, S.

    1988-01-01

    This paper refers to the industrial application of image processing using Non Destructive Testing by radiography. The various problems involved by the conception of a numerical tool are described. This tool intends to help radiograph experts to quantify defects and to follow up their evolution, using numerical techniques. The sequences of processings that achieve defect segmentation and quantization are detailed. They are based on the thorough knowledge of radiographs formation techniques. The process uses various methods of image analysis, including textural analysis and morphological mathematics. The interface between the final product and users will occur in an explicit language, using the terms of radiographic expertise without showing any processing details. The problem is thoroughly described: image formation, digitization, processings fitted to flaw morphology and finally product structure in progress. 12 refs [fr

  11. Endodontic radiography: who is reading the digital radiograph?

    Science.gov (United States)

    Tewary, Shalini; Luzzo, Joseph; Hartwell, Gary

    2011-07-01

    Digital radiographic imaging systems have undergone tremendous improvements since their introduction. Advantages of digital radiographs over conventional films include lower radiation doses compared with conventional films, instantaneous images, archiving and sharing images easily, and manipulation of several radiographic properties that might help in diagnosis. A total of 6 observers including 2 endodontic residents, 3 endodontists, and 1 oral radiologist evaluated 150 molar digital periapical radiographs to determine which of the following conditions existed: normal periapical tissue, widened periodontal ligament, or presence of periapical radiolucency. The evaluators had full control over the radiograph's parameters of the Planmeca Dimaxis software program. All images were viewed on the same computer monitor with ideal vie-wing conditions. The same 6 observers evaluated the same 150 digital images 3 months later. The data were analyzed to determine how well the evaluators agreed with each other (interobserver agreement) for 2 rounds of observations and with themselves (intraobserver agreement). Fleiss kappa statistical analysis was used to measure the level of agreement among multiple raters. The overall Fleiss kappa value for interobserver agreement for the first round of interpretation was 0.34 (P value for interobserver agreement for the second round of interpretation was 0.35 (P fair (0.2-0.4) agreement among the 6 raters at both observation periods. A weighted kappa analysis was used to determine intraobserver agreement, which showed on average a moderate agreement. The results indicate that the interpretation of a dental radiograph is subjective, irrespective of whether conventional or digital radiographs are used. The factors that appeared to have the most impact were the years of experience of the examiner and familiarity of the operator with a given digital system. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All

  12. Radiographers and radiologists reporting plain radiograph requests from accident and emergency and general practice

    International Nuclear Information System (INIS)

    Brealey, S.D.; King, D.G.; Hahn, S.; Crowe, M.; Williams, P.; Rutter, P.; Crane, S.

    2005-01-01

    AIM: To assess selectively trained radiographers and consultant radiologists reporting plain radiographs for the Accident and Emergency Department (A and E) and general practitioners (GPs) within a typical hospital setting. METHODS: Two radiographers, a group of eight consultant radiologists, and a reference standard radiologist independently reported under controlled conditions a retrospectively selected, random, stratified sample of 400 A and E and 400 GP plain radiographs. An independent consultant radiologist judged whether the radiographer and radiologist reports agreed with the reference standard report. Clinicians then assessed whether radiographer and radiologist incorrect reports affected confidence in their diagnosis and treatment plans, and patient outcome. RESULTS: For A and E and GP plain radiographs, respectively, there was a 1% (95% confidence interval (CI) -2 to 5) and 4% (95% CI -1 to 8) difference in reporting accuracy between the two professional groups. For both A and E and GP cases there was an 8% difference in the clinicians' confidence in their diagnosis based on radiographer or radiologist incorrect reports. For A and E and GP cases, respectively, there was a 2% and 8% difference in the clinicians' confidence in their management plans based on radiographer or radiologist incorrect reports. For A and E and GP cases, respectively, there was a 1% and 11% difference in effect on patient outcome of radiographer or radiologist incorrect reports. CONCLUSION: There is the potential to extend the reporting role of selectively trained radiographers to include plain radiographs for all A and E and GP patients. Further research conducted during clinical practice at a number of sites is recommended

  13. Radionuclide Imaging of Musculoskeletal Injuries in Athletes with Negative Radiographs.

    Science.gov (United States)

    Nagle, C E; Freitas, J E

    1987-06-01

    In brief: Radionuclide bone scans can be useful in the diagnostic evaluation of musculoskeletal injuries in athletes. Bone scans can detect shinsplints, stress fractures, and muscle injuries before they are detectable on radiographs. Prognosis can be accurately assessed, allowing appropriate treatment to proceed without delay. The authors discuss the use of bone scans and identify musculoskeletal injuries that are associated with specific sports, such as stress fracture of the femur (soccer), tibia (running), scapula (gymnastics), and pars interarticularis (football or lacrosse).

  14. Evaluation of the styloid process on digital panoramic radiographs

    International Nuclear Information System (INIS)

    More, Chandramani B; Asrani, Mukesh K

    2010-01-01

    The styloid process is an anatomical structure, whose clinical importance is not well understood. Proper clinical and radiographic evaluation can detect an elongated styloid process and calcification of the stylohyoid ligament. It has been reported that 2 – 28% of the general population show radiographic evidence of mineralization of a portion of the stylohyoid chain. The elongated styloid process may be symptomatic in many cases. Panoramic radiography is the best imaging modality to view the styloid process bilaterally. To assess the styloid process on digital panoramic radiographs. The study was conducted on 500 digital panoramic radiographs available in the archives of our department as soft copies. These radiographs were taken using a digital panoramic system. The radiographic length of the styloid process was measured on both sides using the measurement toolbars on the accompanying analysis software. For statistical analysis we used the unpaired t test, Chi-square test, and one-way ANOVA test, as necessary. The average length of the left styloid was 25.41 ± 6.32 mm and that of the right styloid was 25.53 ± 6.62 mm. The length of both styloids increased with age and males had longer styloids than females. Elongated styloids were present in 19.4% of the panoramic radiographs. Langlais type I elongated styloids and a partial calcification pattern were more common than others. Panoramic radiography is useful for detection of an elongated styloid process and / or ossification of the stylohyoid ligament in patients with or without symptoms, and helps avoid a misdiagnosis of tonsillar pain or pain of dental, pharyngeal, or muscular origin

  15. A comparative analysis of emotional intelligence in the UK and Australian radiographer workforce

    International Nuclear Information System (INIS)

    Mackay, S.J.; Baker, R.; Collier, D.; Lewis, S.

    2013-01-01

    Emotional intelligence (EI) in the UK radiographer workforce has been benchmarked using the trait emotional intelligence model and the profile of the profession in the UK has begun to emerge. There are cultural differences between countries that have been shown to have an effect on EI, therefore this paper aims to benchmark the Global and four factor scores of Trait EI in the Australian radiographer population; to explore any differences within the two main professional groupings, diagnostic and therapeutic radiographers, and to compare the Australian radiographer workforce scores with those of the UK previously published. The published and validated trait EI questionnaire of Petrides was used as the survey tool for the Global EI and the four factors of Well-being, Emotionality, Self-control and Sociability. There was only one difference found in the five factors studied between the UK and Australian radiographer workforce, that of Well-being (p ≤ 0.01). No differences emerged between the diagnostic and therapy disciplines nor was a relationship found between EI and the Australian leadership in contrast to the UK workforce findings. Differences were found in the demographic profiles of the two countries and the implications of the above findings are discussed. This paper has benchmarked the EI of the Australian workforce and found a difference in well-being between the UK and Australian radiographer workforce. The Australian diagnostic and therapy disciplines were no different in their EI profiles. No relationship was found between EI and leadership in the Australian radiographer workforce

  16. Radiographic evaluation of INBONE total ankle arthroplasty: a retrospective analysis of 30 cases

    International Nuclear Information System (INIS)

    Datir, Abhijit; Xing, Minzhi; Kakarala, Aparna; Terk, Michael R.; Labib, Sameh A.

    2013-01-01

    The objectives of this work were to retrospectively describe the radiographic assessment of INBONE total ankle arthroplasty in 30 patients using validated linear and angular measurements and to correlate these findings with the final surgical outcome over a 2-year follow-up period. Thirty consecutive patients (21 females, nine males; mean age, 64.8 years) underwent INBONE total ankle arthroplasty during 2007-2011. After IRB approval, a retrospective pre- and post-operative radiographic analysis was performed using validated linear and angular measurements. The pre- and post-operative assessment included the tibial angle, talar angle, tibial slope, and coronal deformity. Post-operative measurements also included the talocalcaneal angle, joint space height, talar height, lateral tibial component angle, lateral talar component angle, and anteroposterior tibial component angle. The post-operative bone loss, subluxation, positioning, and subsidence were also assessed. Statistical analysis was performed using two-sample t test and Fisher's exact test. Out of 30 patients, 23 had a successful clinical outcome with intact prosthesis at a 2-year follow-up. The only variables with significant correlation (p < 0.05) to the post-surgical outcome were the lateral talar component angle (p = 0.002) and the mean difference between pre- and post-operative tibial slope (p = 0.001). The coronal deformity had significant mean difference between pre- and post-operative values (p < 0.001); however, it lacked a significant correlation to the final surgical outcome. None of the categorical variables had a significant correlation with post-surgical outcome. In our retrospective study, only the lateral talar component angle and the mean difference between the pre- and post-operative tibial slope had significant correlation with post-surgical outcome in INBONE ankle arthroplasty. These measurements may be helpful in radiographic assessment of the INBONE ankle arthroplasty. (orig.)

  17. incidence of occupational stress among medical radiographers

    African Journals Online (AJOL)

    Job satisfaction rating was 61.3% and anxiety level was 45.3%. This study has provided a baseline stress level and prevalence among ... theoretical terms predisposes the individual to increased ... checked, burnout ensures. Burnout is an individual's reaction to chronic stress .... neurovegetative functioning of the mental but.

  18. A procedure for the evaluation of 2D radiographic texture analysis to assess 3D bone micro-architecture

    International Nuclear Information System (INIS)

    Apostol, L.; Peyrin, F.; Yot, S.; Basset, O.; Odet, Ch.; Apostal, L.; Peyrin, F.; Boller, E.; Tabary, J.; Dinten, J.M.; Boudousq, V.; Kotzki, P.O.

    2004-01-01

    Although the diagnosis of osteoporosis is mainly based on Dual X-ray Absorptiometry, it has been shown that trabecular bone micro-architecture is also an important factor in regards of fracture risk, which can be efficiently assessed in vitro using three-dimensional x-ray microtomography (μCT). In vivo, techniques based on high-resolution x-ray radiography associated to texture analysis have been proposed to investigate bone micro-architecture, but their relevance for giving pertinent 3D information is unclear. The purpose of this work was to develop a method for evaluating the relationships between 3D micro-architecture and 2D texture parameters, and optimizing the conditions for radiographic imaging. Bone sample images taken from cortical to cortical were acquired using 3D-synchrotron x-ray μCT at the ESRF. The 3D digital images were further used for two purposes: 1) quantification of three-dimensional bone micro-architecture, 2) simulation of realistic x-ray radiographs under different acquisition conditions. Texture analysis was then applied to these 2D radiographs using a large variety of methods (co-occurrence, spectrum, fractal...). First results of the statistical analysis between 2D and 3D parameters allowed identifying the most relevant 2D texture parameters. (authors)

  19. The basal cell naevus syndrome - radiographic findings in the skull

    International Nuclear Information System (INIS)

    Stoll, P.; Dueker, J.; Weingart, D.

    1986-01-01

    Besides uni- and multiocular jaw cysts the Gorlin Goltz syndrome shows other characteristic radiographic findings which help to ensure diagnosis. These are particularly calcification of the falx cerebri and a so called ''bridging'' between processus clinoideus anterior and posterior of the sella turcica. The importance of early diagnosis is stressed. (orig.) [de

  20. Aortic stentgraft movement detection using digital roentgen stereophotogrammetric analysis on plane film radiographs - initial results of a phantom study

    International Nuclear Information System (INIS)

    Georg, C.; Welker, V.; Eidam, H.; Alfke, H.

    2005-01-01

    Purpose: To evaluate the feasibility of aortic stentgraft micromovement detection using digital roentgen stereophotogrammetric analysis on plane film radiographs. Material and Methods: An aortic stentgraft used for demonstration purposes was marked with 10 tantalum markers of 0.8 mm in diameter. The stentgraft was placed on a Plexiglas phantom with 5 tantalum markers of 1 mm in diameter simulating a fixed segment needed for mathematical analysis. In a subsequent step, the stentgraft was placed onto an orthopaedic spine model to simulate in vivo conditions in a next step.Two radiographs taken simultaneously from different angles were used for simulating different stentgraft movement, e.g. translation, angulation, aortic pulsation and migration in the spine model. Movement of the stentgraft markers was analysed using a commercially available digital RSA setup (UmRSA registered 4.1, RSA Biomedical, Umea, Sweden). Results: Our study shows the feasibility of measuring aortic stentgraft movement and changes in stentgraft shape in the submillimeter range using digital roentgen stereophotogrammetric analysis. Translation along the 3 cardinal axes, change in stentgraft shape, simulation of aortic pulsation and simulation of in vivo conditions could be described precisely. Conclusion: Aortic stentgraft movement detection using digital roentgen stereophotogrammetric analysis on plane film radiographs is a very promising, precise method. (orig.)

  1. Analysis of radiographic bone parameters throughout the surgical lengthening and deformity correction of extremities.

    Science.gov (United States)

    Atanasov, Nenad; Poposka, Anastasika; Samardziski, Milan; Kamnar, Viktor

    2014-01-01

    Radiographic examination of extremities in surgical lengthening and/or correction of deformities is of crucial importance for the assessment of new bone formation. The purpose of this study is to confirm the diagnostic value of radiography in precise detection of bone parameters in various lengthening or correction stages in patients treated by limb-lengthening and deformity correction. 50 patients were treated by the Ilizarov method of limb lengthening or deformity correction at the University Orthopaedic Surgery Clinic in Skopje, and analysed over the period from 2006 to 2012. The patients were divided into two groups. The first group consisted of 27 patients with limb-lengthening because of congenital shortening. The second group consisted of 23 patients treated for acquired limb deformities. The results in both groups were received in three stages of new bone formation and were based on the appearance of 3 radiographic parameters at the distraction/compression site. The differences between the presence of all radiographic bone parameters in different stages of new bone formation were statistically signficant in both groups, especially the presence of the cortical margin in the first group (Cochran Q=34.43, df=2, p=0.00000). The comparative analysis between the two groups showed a statistically significant difference in the presence of initial bone elements and cystic formations only in the first stage. Almost no statistical significance in the differences between both groups of patients with regard to 3 radiographic parameters in 3 stages of new bone formation, indicates a minor influence of the etiopathogenetic background on the new bone formation in patients treated by gradual lengthening or correction of limb deformities.

  2. Medullar fat influences texture analysis of trabecular microarchitecture on X-ray radiographs

    International Nuclear Information System (INIS)

    Chappard, Daniel; Pascaretti-Grizon, Florence; Gallois, Yves; Mercier, Philippe; Basle, Michel F.; Audran, Maurice

    2006-01-01

    Alteration of trabecular architecture is a predictor of fracture risk in osteoporosis. Until now, microarchitecture analysis is difficult to evaluate in routine clinical practice for osteoporosis. Texture analysis on X-ray images has been advocated to be a suitable method to assess microarchitecture in bone diseases. The X-ray acquisition conditions have been often taken into consideration; however, the influence of anatomical conditions on texture parameters has received little interest. Because fat is a well-known problem with computed tomography and densitometry, we have designed a cadaver study to compare the influence of marrow lipids on numerous texture parameters. Twenty-one human distal radii were obtained, radiographed, and analyzed using a software that measures: heterogeneity, skeletonized parameters, run-lengths and fractal dimensions. Texture parameters were measured before, and after an extensive delipidation period lasting 3 weeks. Quality of the radiographs was improved after defatting. Delipidation had a very significant effect on measurements: afterwards defatting, the images were less blurred, and a better delineation of trabeculae and marrow cavities was obtained. This provoked an increase of parameters based on the grey level distribution but had no influence on parameters describing the reticulated honeycomb microarchitecture of the trabeculae (i.e., fractal dimension). Some parameters appeared anisotropy-sensitive, due to the different constitution and size of the trabeculae. The fat content of bone marrow induces noise that can modify some texture parameters. One should take into account the fat content of the marrow when using texture analysis to compare patients with osteoporosis due to various etiologies

  3. The radiographic image: A cultural artefact?

    International Nuclear Information System (INIS)

    Strudwick, Ruth M.

    2014-01-01

    This article looks at the role of the radiographic images produced by diagnostic radiographers. An ethnographic study of the workplace culture in one diagnostic imaging department was undertaken using participant observation for four months and semi-structured interviews with ten key informants. One of the key themes; that of the radiographic image as a cultural artefact, is explored in this article. The radiographic image is a cultural artefact which radiographers are protective of and take ownership of. Radiographers are conscious of the quality of their images and the images are an important aspect of their work. Radiographers take criticism of their images personally. The radiographic image is a record of the interaction that occurs between the radiographer and the patient. The way in which radiographic images are viewed, used and judged is an important aspect of the role of diagnostic radiographer

  4. Evaluation of the styloid process on digital panoramic radiographs

    Directory of Open Access Journals (Sweden)

    More Chandramani

    2010-01-01

    Full Text Available Background: The styloid process is an anatomical structure, whose clinical importance is not well understood. Proper clinical and radiographic evaluation can detect an elongated styloid process and calcification of the stylohyoid ligament. It has been reported that 2 - 28% of the general population show radiographic evidence of mineralization of a portion of the stylohyoid chain. The elongated styloid process may be symptomatic in many cases. Panoramic radiography is the best imaging modality to view the styloid process bilaterally. Aim: To assess the styloid process on digital panoramic radiographs. Materials and Methods: The study was conducted on 500 digital panoramic radiographs available in the archives of our department as soft copies. These radiographs were taken using a digital panoramic system. The radiographic length of the styloid process was measured on both sides using the measurement toolbars on the accompanying analysis software. For statistical analysis we used the unpaired t test, Chi-square test, and one-way ANOVA test, as necessary. Results: The average length of the left styloid was 25.41 ± 6.32 mm and that of the right styloid was 25.53 ± 6.62 mm. The length of both styloids increased with age and males had longer styloids than females. Elongated styloids were present in 19.4% of the panoramic radiographs. Langlais type I elongated styloids and a partial calcification pattern were more common than others. Conclusion: Panoramic radiography is useful for detection of an elongated styloid process and / or ossification of the stylohyoid ligament in patients with or without symptoms, and helps avoid a misdiagnosis of tonsillar pain or pain of dental, pharyngeal, or muscular origin.

  5. Basic stress analysis

    CERN Document Server

    Iremonger, M J

    1982-01-01

    BASIC Stress Analysis aims to help students to become proficient at BASIC programming by actually using it in an important engineering subject. It also enables the student to use computing as a means of learning stress analysis because writing a program is analogous to teaching-it is necessary to understand the subject matter. The book begins by introducing the BASIC approach and the concept of stress analysis at first- and second-year undergraduate level. Subsequent chapters contain a summary of relevant theory, worked examples containing computer programs, and a set of problems. Topics c

  6. THR Simulator – the software for generating radiographs of THR prosthesis

    Directory of Open Access Journals (Sweden)

    Hou Sheng-Mou

    2009-01-01

    Full Text Available Abstract Background Measuring the orientation of acetabular cup after total hip arthroplasty is important for prognosis. The verification of these measurement methods will be easier and more feasible if we can synthesize prosthesis radiographs in each simulated condition. One reported method used an expensive mechanical device with an indeterminable precision. We thus develop a program, THR Simulator, to directly synthesize digital radiographs of prostheses for further analysis. Under Windows platform and using Borland C++ Builder programming tool, we developed the THR Simulator. We first built a mathematical model of acetabulum and femoral head. The data of the real dimension of prosthesis was adopted to generate the radiograph of hip prosthesis. Then with the ray tracing algorithm, we calculated the thickness each X-ray beam passed, and then transformed to grey scale by mapping function which was derived by fitting the exponential function from the phantom image. Finally we could generate a simulated radiograph for further analysis. Results Using THR Simulator, the users can incorporate many parameters together for radiograph synthesis. These parameters include thickness, film size, tube distance, film distance, anteversion, abduction, upper wear, medial wear, and posterior wear. These parameters are adequate for any radiographic measurement research. This THR Simulator has been used in two studies, and the errors are within 2° for anteversion and 0.2 mm for wearing measurement. Conclusion We design a program, THR Simulator that can synthesize prosthesis radiographs. Such a program can be applied in future studies for further analysis and validation of measurement of various parameters of pelvis after total hip arthroplasty.

  7. Initial image interpretation of appendicular skeletal radiographs: A comparison between nurses and radiographers

    International Nuclear Information System (INIS)

    Piper, Keith J.; Paterson, Audrey

    2009-01-01

    Purpose: To examine the effect of a short training programme on nurses and radiographers, exploring differences between their performance before and after training. Method: Twenty-two nurses and 18 radiographers interpreted 20 trauma radiographs of the appendicular skeleton before and after training. Normal and abnormal cases of a discriminatory nature were included. Total score, sensitivity and specificity values were calculated for each participant by comparison with an agreed expected answer. The area under the curve (AUC) was analysed using alternate free-response receiver operating characteristic (AFROC) methodology. Results: Significant differences were demonstrated between the total scores achieved by the two groups (pre-training: p = 0.007, post-training: p = 0.04). After training, the mean score increased significantly for both groups (p < 0.001). No significant difference was found between the radiographers mean pre-training scores and the nurses mean post-training scores (p = 0.66). Sensitivity for both groups increased following training, significantly so for the nurses (nurses: p < 0.001, radiographers: p = 0.06). Specificity reduced significantly after training for the nurses (p < 0.001), and increased for the radiographers but not significantly (p = 0.085). After training, there was no significant difference between the two groups in terms of sensitivity (p = 0.09) but specificity was significantly higher for the radiographers (p < 0.001). The radiographers achieved higher pre-training AUC values than the nurses (p = 0.04), although a difference remained after training this did not achieve statistical significance (p = 0.15). The AUC values increased significantly after training for both groups (nurses: p = 0.012, radiographers: p = 0.004) and again there was no significant difference between the radiographers pre-training performance and the nurses post-training performance (p = 0.62). Conclusion: Improvement after training was seen in both groups

  8. Radiographers and trainee radiologists reporting accident radiographs: A comparative plain film-reading performance study

    International Nuclear Information System (INIS)

    Buskov, L.; Abild, A.; Christensen, A.; Holm, O.; Hansen, C.; Christensen, H.

    2013-01-01

    Aim: To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital. Materials and methods: Plain radiographs of the appendicular skeleton from 1000 consecutive emergency room patients were included in the study: 500 primarily reported by radiographers and 500 by trainee radiologists. The final reporting was subsequently undertaken by a consultant radiologist in consensus with an orthopaedic surgeon. Two observers classified reports as either true positive/negative or false positive/negative based on the final report, which was considered the reference standard. To evaluate the severity of incorrect primary reports, errors were graded into three categories concerning clinical impact and erroneous reports graded as the most severe category were subsequently analysed. Mann–Whitney and Chi-squared tests were used to compare differences and associations between radiographers versus trainee radiologists regarding film reporting. Results: The sensitivity for correct diagnosis was 99% for reporting radiographers and 94% for trainee radiologists. The specificity was found to be 97% for reporting radiographers and 99% for trainee radiologists. Radiographers missed significantly fewer fractures (n = 2) than trainee radiologists (n = 14; p = 0.006) but had a higher, but not significant, degree of overcalling. No significant difference was found between groups regarding clinical impact of incorrect reporting. Conclusion: Trained radiographers report accident radiographs of the extremities with high accuracy and constitute a qualified resource to help meet increasing workload and demands in quality standards.

  9. Radiographic constant exposure technique

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1985-01-01

    The constant exposure technique has been applied to assess various industrial radiographic systems. Different X-ray films and radiographic papers of two producers were compared. Special attention was given to fast film and paper used with fluorometallic screens. Radiographic image quality...... was tested by the use of ISO wire IQI's and ASTM penetrameters used on Al and Fe test plates. Relative speed and reduction of kilovoltage obtained with the constant exposure technique were calculated. The advantages of fast radiographic systems are pointed out...

  10. The reliability of tablet computers in depicting maxillofacial radiographic landmarks

    Energy Technology Data Exchange (ETDEWEB)

    Tadinada, Aditya; Mahdian, Mina; Sheth, Sonam; Chandhoke, Taranpreet K.; Gopalakrishna, Aadarsh; Potluri, Anitha; Yadav, Sumit [University of Connecticut School of Dental Medicine, Farmington (United States)

    2015-09-15

    This study was performed to evaluate the reliability of the identification of anatomical landmarks in panoramic and lateral cephalometric radiographs on a standard medical grade picture archiving communication system (PACS) monitor and a tablet computer (iPad 5). A total of 1000 radiographs, including 500 panoramic and 500 lateral cephalometric radiographs, were retrieved from the de-identified dataset of the archive of the Section of Oral and Maxillofacial Radiology of the University Of Connecticut School Of Dental Medicine. Major radiographic anatomical landmarks were independently reviewed by two examiners on both displays. The examiners initially reviewed ten panoramic and ten lateral cephalometric radiographs using each imaging system, in order to verify interoperator agreement in landmark identification. The images were scored on a four-point scale reflecting the diagnostic image quality and exposure level of the images. Statistical analysis showed no significant difference between the two displays regarding the visibility and clarity of the landmarks in either the panoramic or cephalometric radiographs. Tablet computers can reliably show anatomical landmarks in panoramic and lateral cephalometric radiographs.

  11. Fractal dimension analysis in digital periapical radiographs: A diagnostic indicator of osteoporosis in post-menopausal women

    Directory of Open Access Journals (Sweden)

    Mathivanan Kavitha

    2017-01-01

    Full Text Available Objectives: To assess the alveolar bone density by fractal dimension (FD analysis in radiovisiograph of postmenopausal women of mandibular posterior region and to correlate FD values with t-scores of quantitative ultrasound of the calcaneus bone. Materials and Methods: This study, approved by the institutional review board, included 40 participants, aged 45–60 years divided into two groups. Twenty postmenopausal women with osteoporosis comprised group 1, and 20 postmenopausal women without osteoporosis comprised group 2 based on bone mineral density assessment of ultrasound of the calcaneus bone. Digital dental radiograph of mandibular first molar were obtained and used for assessing alveolar bone density by FD analysis and were correlated with t-scores of ultrasound of calcaneus bone. Results: The mean FD values were evaluated using SPSS 14 version software, and were found to be 1.738 and 1.867 for group 1 and group 2, respectively, which was statistically significant (P 0.05. Conclusion: FD analysis using direct digital periapical radiographs is a novel method, which can be used for early diagnosis of osteoporosis in the alveolar bone.

  12. Visual simulation of radiographs

    International Nuclear Information System (INIS)

    Laguna, G.

    1985-01-01

    A method for computer simulation of radiographs has been added to the LLNL version of the solid modeler TIPS-1 (Technical Information Processing System-1). This new tool will enable an engineer to compare an actual radiograph of a solid to its computer-generated counterpart. The appearance of discrepancies between the two can be an indication of flaws in the solid object. Simulated radiographs can also be used to preview the placement of x-ray sources to focus on areas of concern before actual radiographs are made

  13. A radiographic investigation of third carpal bone injury in 42 racing thoroughbreds

    International Nuclear Information System (INIS)

    De Haan, C.E.; O'Brien, T.R.; Koblik, P.D.

    1987-01-01

    A retrospective study of carpal radiographs from 42 racing thoroughbreds with carpal lameness was performed. Radiographs from 50 carpal examinations were available for review. The radiographic findings pertaining to the third carpal bone were described. Fractures and/or sclerosis occurred almost exclusively within the radial fossa. The occurrence of sclerosis without fracture in 20 of the 50 carpal examinations was higher than anticipated, occurring in both the right and left third carpal bone with equal frequency. The right third carpal bone was more frequently fractured and more severely affected than the left. The sclerotic changes seen in the radial fossa of the third carpal bone may be stress-induced, possibly preceding more serious changes in the joint such as cartilage damage or gross fracture. Earlier recognition of sclerosis of the third carpal bone may help prevent more serious changes from occurring

  14. Radiographic examination of the equine foot

    International Nuclear Information System (INIS)

    Park, R.D.

    1989-01-01

    A complete radiographic examination of the equine foot consists of properly exposed, processed, and positioned radiographs. For radiographic interpretation, in addition to knowing radiographic signs of disease, a knowledge of normal radiographic anatomy and possible insignificant anatomic variations is necessary

  15. Benchmarking the performance of fixed-image receptor digital radiographic systems part 1: a novel method for image quality analysis.

    Science.gov (United States)

    Lee, Kam L; Ireland, Timothy A; Bernardo, Michael

    2016-06-01

    This is the first part of a two-part study in benchmarking the performance of fixed digital radiographic general X-ray systems. This paper concentrates on reporting findings related to quantitative analysis techniques used to establish comparative image quality metrics. A systematic technical comparison of the evaluated systems is presented in part two of this study. A novel quantitative image quality analysis method is presented with technical considerations addressed for peer review. The novel method was applied to seven general radiographic systems with four different makes of radiographic image receptor (12 image receptors in total). For the System Modulation Transfer Function (sMTF), the use of grid was found to reduce veiling glare and decrease roll-off. The major contributor in sMTF degradation was found to be focal spot blurring. For the System Normalised Noise Power Spectrum (sNNPS), it was found that all systems examined had similar sNNPS responses. A mathematical model is presented to explain how the use of stationary grid may cause a difference between horizontal and vertical sNNPS responses.

  16. A full-mouth radiographic survey of periodontal bone loss in dogs

    International Nuclear Information System (INIS)

    Pavlica, Z.; Erjavec, V.; Erzen, D.; Petelin, M.

    2003-01-01

    The objective of this study was to evaluate the relationship between clinically observed periodontal disease indicators and radiographic findings using fullmouth radiographs in poodles. The dogs were divided into three groups according to their age. Upper and lower incisors, canines and premolars/molars were used for clinical and radiographic analyses. The prevalence and severity of periodontal disease increased with age. In addition, the deepest pockets and most severe bone loss were found around the canine teeth. The values obtained from radiographic analysis correlated well with clinical measurements. Fullmouth radiographic surveys show clearly the alveolar bone level around the whole dentition of dogs. It should be performed prior to the institution of any treatment

  17. Radiographic testing

    International Nuclear Information System (INIS)

    Kuster, J.

    1978-01-01

    In view of great differencies in X-ray transmission it is more difficult to get optimum radiographs of plastics and especially of reinforced plastics than for example of metals. A procedure will be reported how to get with little effort optimum radiographs especially also in the range of long wave-length radiation corresponding 10 to 25 kV.P. (orig.) [de

  18. Assessment of the willingness of Australian radiographers in mammography to accept new responsibilities in role extension: Part two – qualitative analysis

    International Nuclear Information System (INIS)

    Moran, S.; Taylor, J.K.; Warren-Forward, H.

    2013-01-01

    Advanced practice in screening mammography has become widespread in the United Kingdom over the last 20 years, and Australian radiographers working in BreastScreen programs have shown interest in similar developments. Radiographers working in BreastScreen Australia were surveyed in order to capture their thoughts and perceptions on role extension. Questionnaires were circulated to radiographers working in BreastScreen Australia programs. Thematic analysis was used to analyze the open response questions to explore the advantages and disadvantages identified by the participants with respect to role expansion in screening mammography as well as any changes to their duties over the last decade. There were 253 responses to the survey and of those responses, 70% of radiographers shared their thoughts on role extension and 49% provided comments on changes in the workplace. The majority (61%) radiographers responding to the role extension question were concerned about potential problems associated with role extension; the biggest issues were that role extension should not be mandatory and that selection criteria for advanced practitioners should be stringent, with adequate time made available for training and study. The major change in the role of the radiographer has been the increased time dedicated to quality assurance tasks and administrative duties as well as more training required due to technological changes from film-screen to digital mammography. There is high interest in role extension by radiographers working in BreastScreen programs, provided that it is voluntary. The role of the radiographer within breast imaging in Australia is still evolving

  19. Analysis the findings of chest radiograph and CT scan in 217 acute thoracic trauma

    International Nuclear Information System (INIS)

    Huang Shaoying

    2005-01-01

    Objective: To evaluate chest radiograph and CT scan in assessing acute thoracic trauma. Methods: Retrospectively analyzed the findings of chest radiograph and CT scan in 217 cases of acute thoracic trauma and positive rate of each modality was compared. Results: The positive rate of rib and clavicle fracture was higher in chest radiograph than these in CT scan. But the positive rate of chest wall hematoma, mediastinum and subcutaneous emphysema, pneumothorax, hydropneumothorax, damage of lung parenchyma and traumatic pulmonary atelectasis was higher in CT scan than those in chest radiograph. Conclusion: The application of the combined imaging modalities improves assessing of acute thoracic trauma, because the imaging manifestation of the lesion is various. (authors)

  20. An evaluation of musculoskeletal discomfort experience by radiographers performing mammography

    Energy Technology Data Exchange (ETDEWEB)

    Gale, A.G.; May, J

    1997-10-01

    The aim of this study was to establish whether breast screening radiographers experience any problems of musculoskeletal discomfort, and if so the nature and extent of these problems. The study was then further extended to investigate and determine possible occupational, causal or contributory factors, and to suggest recommendations to help alleviate any discomfort. To investigate this problem five main approaches were undertaken. These consisted of; a national survey, an observational study, the comparison of the physical measurements of the mammography units with anthropometric data, a detailed task analysis, and a body mapping study. The national survey set out to determine if the nature and frequency of such problems were higher in mammography than in other areas of radiography or in the general population. Additionally, comparisons were made with non-radiographic staff working at the same breast screening centres. Video recordings of radiographers performing breast screening were also made and posture analysis performed on these data. A detailed task analysis was conducted to identify interaction points and possible problems between the radiographer and the equipment which she is required to use. Physical measurements of the mammography units were made and compared with anthropometric measurements and guidelines. The body mapping study measured the build up of discomfort throughout the working day on several different mammography units. The results from the survey questionnaire indicated that some breast screening radiographers do experience musculoskeletal problems, and that these are different in nature and prevalence from the musculoskeletal discomfort reported by the two control groups. The prevalence of back pain reported by radiographers undertaking mammography was higher than that present in the normal population. No comparison could be made with other body areas as data regarding other types of musculoskeletal discomfort in the general population are

  1. Assessment of Radiographic Image Quality by Visual Examination of Neutron Radiographs of the Calibration Fuel Pin

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Up till now no reliable radiographic image quality standards exist for neutron radiography of nuclear reactor fuel. Under the Euratoro Neutron Radiography Working Group (NRWG) Test Program neutron radiographs were produced at different neutron radiography facilities within the European Community...... of a calibration fuel pin. The radiographs were made by the direct, transfer and tracketch methods using different film recording materials. These neutron radiographs of the calibration fuel pin were used for the assessement of radiographic image quality. This was done by visual examination of the radiographs...

  2. Experimental analysis of motion artifacts in chest radiographs with the AMBER system

    International Nuclear Information System (INIS)

    Boetticher, H. von; Hofmann, K.; Luska, G.

    1999-01-01

    The prerequisites, mechanisms and principles of motion artifacts in AMBER radiographs were analysed. The experiments were performed using metronomes, a moving conventional mammography phantom, and arrangements of oscillating coil spring, spheroid and grid elements. A diagnostic dosimeter and TLDs, respectively, were used to measure exposure times and doses. The deree of distortion in AMBER radiographs depends on the direction of the object movement relative to the AMBER fan beam in a complex manner. The size of the motion artifacts depends on the local exposure time. The maximum value of this time is 75 ms and thus 1.5 times higher than specified by the manufacturer. To interpret AMBER radiographs possible system specific artifacts have to be considered to avoid misinterpretations of potentially significant details. (orig.) [de

  3. Modeling dental radiographic systems

    International Nuclear Information System (INIS)

    Webber, R.L.

    1980-01-01

    The Bureau of Radiological Health has been actively collaborating with the Clinical Investigations Branch, NIDR, in applied research involving diagnostic use of ionizing radiation in dentistry. This work has centered on the search for alternatives to conventional radiographic systems in an attempt to improve diagnostic performance while reducing the required exposure. The basic approach involves analysis of factors limiting performance of properly defined diagnostic tasks and the modeling alternative systems with an eye toward increasing objective measures of performance. Previous collaborative work involved using a nonlinear model to compare various x-ray spectra. The data were expressed as brightness-contrast versus exposure for simulated tasks of clinical interest. This report supplements these findings by extending the number of parameters under investigation and modifying the mode of data display so that an actual radiographic image can be simulated on a television screen

  4. Radiographic Test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H.J; Yang, S.H. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    This report contains theory, procedure technique and interpretation of radiographic examination and written for whom preparing radiographic test Level II. To determine this baseline of technical competence in the examination, the individual must demonstrate a knowledge of radiography physics, radiation safety, technique development, radiation detection and measurement, facility design, and the characteristics of radiation-producing devices and their principles of operation. (author) 98 figs., 23 tabs.

  5. High-resolution axial MR imaging of tibial stress injuries

    Directory of Open Access Journals (Sweden)

    Mammoto Takeo

    2012-05-01

    Full Text Available Abstract Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries.

  6. High-resolution axial MR imaging of tibial stress injuries

    Science.gov (United States)

    2012-01-01

    Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries. PMID:22574840

  7. Mammography in breast cancer screening. A radiographic analysis of the carcinomas found at Utrecht, Nijmegen and Kopparberg county

    International Nuclear Information System (INIS)

    Muller, J.W.T.

    1985-01-01

    Population-based screening for carcinoma of the breast by mammography has yielded an abundance of data, not all of which have been processed yet, the mammographic (radiographic) data in particular. The present study concerns an analysis of the mammographic signs in the histologically proven carcinomas (invasive and intraductal) detected by these three screening programs. The radiographic signs of the screened carcinomas were compared with those of the clinical carcinomas diagnosed in the Utrecht University Hospital (to be called AZU carcinomas). These AZU carcinomas were taken as reference material, and were therefore analysed in the same way as the screening material. (Auth.)

  8. Digital image processing of mandibular trabeculae on radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Ogino, Toshi

    1987-06-01

    The present study was aimed to reveal the texture patterns of the radiographs of the mandibular trabeculae by digital image processing. The 32 cases of normal subjects and the 13 cases of patients with mandibular diseases of ameloblastoma, primordial cysts, squamous cell carcinoma and odontoma were analyzed by their intra-oral radiographs in the right premolar regions. The radiograms were digitized by the use of a drum scanner densitometry method. The input radiographic images were processed by a histogram equalization method. The result are as follows : First, the histogram equalization method enhances the image contrast of the textures. Second, the output images of the textures for normal mandible-trabeculae radiograms are of network pattern in nature. Third, the output images for the patients are characterized by the non-network pattern and replaced by the patterns of the fabric texture, intertwined plants (karakusa-pattern), scattered small masses and amorphous texture. Thus, these results indicates that the present digital image system is expected to be useful for revealing the texture patterns of the radiographs and in the future for the texture analysis of the clinical radiographs to obtain quantitative diagnostic findings.

  9. Computed image analysis of neutron radiographs

    International Nuclear Information System (INIS)

    Dinca, M.; Anghel, E.; Preda, M.; Pavelescu, M.

    2008-01-01

    Similar with X-radiography, using neutron like penetrating particle, there is in practice a nondestructive technique named neutron radiology. When the registration of information is done on a film with the help of a conversion foil (with high cross section for neutrons) that emits secondary radiation (β,γ) that creates a latent image, the technique is named neutron radiography. A radiographic industrial film that contains the image of the internal structure of an object, obtained by neutron radiography, must be subsequently analyzed to obtain qualitative and quantitative information about the structural integrity of that object. There is possible to do a computed analysis of a film using a facility with next main components: an illuminator for film, a CCD video camera and a computer (PC) with suitable software. The qualitative analysis intends to put in evidence possibly anomalies of the structure due to manufacturing processes or induced by working processes (for example, the irradiation activity in the case of the nuclear fuel). The quantitative determination is based on measurements of some image parameters: dimensions, optical densities. The illuminator has been built specially to perform this application but can be used for simple visual observation. The illuminated area is 9x40 cm. The frame of the system is a comparer of Abbe Carl Zeiss Jena type, which has been adapted to achieve this application. The video camera assures the capture of image that is stored and processed by computer. A special program SIMAG-NG has been developed at INR Pitesti that beside of the program SMTV II of the special acquisition module SM 5010 can analyze the images of a film. The major application of the system was the quantitative analysis of a film that contains the images of some nuclear fuel pins beside a dimensional standard. The system was used to measure the length of the pellets of the TRIGA nuclear fuel. (authors)

  10. Attitudes of radiographers to radiographer-led discharge: A survey

    International Nuclear Information System (INIS)

    Lumsden, Laura; Cosson, Philip

    2015-01-01

    Background: The traditional role of the Diagnostic Radiographer in image acquisition has gradually been extended through skill-mix, particularly to include abnormality detection. Aims: This research focused on the attitudes of Radiographers to Radiographer-led Discharge (RLD), where Radiographers discharge patients with minor injuries and perform tasks previously undertaken by Accident and Emergency staff. The effects of job role, hospital type, experience and whether RLD was used in the participant's trust were examined. Method: A multiple-indicator online questionnaire assessed attitudes to RLD. Snowball sampling was used with advertisement via emails, posters and cards, containing Quick Response (QR) codes. Statement responses were coded, with reverse coding for negative statements and total scores were calculated. A higher score represented a more positive attitude. Results: 101 questionnaires were completed (an estimated 30% response rate) and the mean total score was 84/115. 95% of participants supported radiographer involvement in abnormality detection, with 46.5% selecting RLD as the preferred system for minor injuries patients vs 48.5% preferring commenting alone. Discussion: Participants were positive about extending their role through RLD and felt confident in their image interpretation abilities, though expressed concern for the legal consequences of the role and adequate pay. Generalization of the results is limited due to the possible low response rate. Conclusion: Overall, participants demonstrated positive attitudes towards RLD but they also indicate the need for appropriate payment for any additional responsibility. These findings are promising for successful implementation of RLD, though larger-scale research including radiologists, business managers, A and E staff and patients would be beneficial. - Highlights: • 101 questionnaires were completed (an estimated 30% response rate). • 95% of participants supported radiographer involvement

  11. Reflections on the role of consultant radiographers in the UK: What is a consultant radiographer?

    International Nuclear Information System (INIS)

    Booth, L.; Henwood, S.; Miller, P.

    2016-01-01

    Context: This paper is the second paper from a two year in depth case study, exploring the role of consultant radiographers in the UK. Methods: A longitudinal case study approach was used to determine the role of consultant radiographers. Interviews were used to explore experiences of being a consultant, which were analysed using thematic analysis. Eight consultant radiographers participated (Note, two of the consultants withdrew after the first interview due to workload). Therefore two consultants were interviewed only once. The remaining six consultants were interviewed twice over a 12 month period. Findings: The data presented in this paper explores the nature of the role, differences between roles, the four domains of practice, and how the role fits into local organisational structures. The study shows wide variation in the types of roles undertaken, reflecting that the creation of these roles were in response to local clinical need and often related to an individual practitioner's skills. The broad scope of the role was shown across all the consultants, with evidence of roles developing into new areas of service delivery. Conclusions: The paper offers insight into the role(s) of consultant radiographers in the UK. The range and scope of their practice is extensive, with much variation. It is evident that the clinical aspect of the role dominates, with research being the least supported domain of practice. There remains a lack of clarity around the role, with concerns about remuneration and other limitations that may restrict the role developing further. - Highlights: • This paper shows the variation in roles between consultant radiographers. • The commonality with medical roles is highlighted. • Problem solving is identified as a core skill in consultant radiography. • Consultants offered evidence of the roles developing service provision. • While all four domains of practice are covered, research is the least well supported.

  12. Children’s experience of going through an acute radiographic examination

    International Nuclear Information System (INIS)

    Björkman, B.; Almqvist, L.; Sigstedt, B.; Enskär, K.

    2012-01-01

    Children’s experience of radiographic examinations remains largely unexplored, although most radiographers examine children on a daily basis. In order to provide the high quality care that meets the needs of patients it was considered important to undertake research focused upon the patients’ experience of radiographic practice. The aim of the study was to investigate children’s experiences undergoing a radiographic examination for a suspected fracture. Inclusion criteria were Swedish-speaking children between 3 and 15 years of age who were submitted for a radiographic examination with an acute condition of the upper or lower extremity. Patients were informed of the study and together with the escorting parent or relative asked for consent to participate. During the examination the child was videotaped and immediately after, the child was interviewed in a nearby facility. The interview contained open-ended questions and was conducted while watching the videotape together with the child and their parent or relative and the researcher. Qualitative content analysis was used in analyzing the collected data. The analysis resulted in two categories – “feeling uncomfortable” and “feeling confident”. The subcategories contained in these categories were “pain in relation to injury and examination”, “the waiting time is strenuous”, “worries for the future and consequences of the injury”, “confidence in parental presence”, “confidence in radiographic staff and examination procedure”, and finally “recognition entails familiarity”. The results revealed that for the younger children, the experience of undergoing an acute radiographic examination was associated with pain and anxiety, but for the older children, the anxiety was more connected to whether the injury had caused a fracture and any anticipated future consequences or complications.

  13. An evaluation of musculoskeletal discomfort experience by radiographers performing mammography

    International Nuclear Information System (INIS)

    Gale, A.G.; May, J.

    1997-01-01

    The aim of this study was to establish whether breast screening radiographers experience any problems of musculoskeletal discomfort, and if so the nature and extent of these problems. The study was then further extended to investigate and determine possible occupational, causal or contributory factors, and to suggest recommendations to help alleviate any discomfort. To investigate this problem five main approaches were undertaken. These consisted of; a national survey, an observational study, the comparison of the physical measurements of the mammography units with anthropometric data, a detailed task analysis, and a body mapping study. The national survey set out to determine if the nature and frequency of such problems were higher in mammography than in other areas of radiography or in the general population. Additionally, comparisons were made with non-radiographic staff working at the same breast screening centres. Video recordings of radiographers performing breast screening were also made and posture analysis performed on these data. A detailed task analysis was conducted to identify interaction points and possible problems between the radiographer and the equipment which she is required to use. Physical measurements of the mammography units were made and compared with anthropometric measurements and guidelines. The body mapping study measured the build up of discomfort throughout the working day on several different mammography units. The results from the survey questionnaire indicated that some breast screening radiographers do experience musculoskeletal problems, and that these are different in nature and prevalence from the musculoskeletal discomfort reported by the two control groups. The prevalence of back pain reported by radiographers undertaking mammography was higher than that present in the normal population. No comparison could be made with other body areas as data regarding other types of musculoskeletal discomfort in the general population are

  14. Pocket atlas of radiographic anatomy

    International Nuclear Information System (INIS)

    Moeller, T.B.; Reif, E.; Stark, P.

    1993-01-01

    The 'Pocket Atlas of Radiographic Anatomy' presents 170 radiographs of the various body regions of adults, showing only the normal radiographic anatomy. Each radiograph is supplemented on the opposite page by a drawing of the particular body region. There is no commenting text, but the drawings are provided with captions in English. The atlas is a useful guide for interpreting radiographs. The pictures are arranged in chapters entitled as follows: Skeletal Imaging (skull, spine, upper extremity), lower extremity; Miscellaneous Plain Films (chest, mammogram, trachea, lung tomograms); Contrast Examinations (gastrointestinal tract, intravenous contrast examinations, arthrography, angiography); Special Examinations (myelograms, lymphangiograms, bronchograms, sialograms). (UWA). 348 figs [de

  15. Reject analysis: A comparison of radiographer and radiologist perceptions of image quality

    International Nuclear Information System (INIS)

    Mount, J.

    2016-01-01

    This study explores the potential differences in perceptions of image quality between radiographers and radiologists in a large UK hospital and the subsequent impact this has on image rejection. Image rejection, while sometimes necessary, often leads to an increased radiation dose to the patient due to the need to repeat. Moreover, this translates into increased waiting times, departmental costs, and lower patient satisfaction. Adopting a mixed methods approach, this paper first seeks to quantify the differences in radiographer and radiologist perceptions and second establish the underlying causes of such differences through a quantitative and qualitative investigation respectively. Using a standardized psychometric scale of a GP lateral knee, the study reveals significant differences in the perceptions of quality and rejection rates between radiographers and radiologists driven by a conflict in the evaluation criteria used. The study has significant implications for improving departmental performance and proposes a potential solution for reducing reject rates and image repeats. - Highlights: • Significant differences are found to exist in perceptions of image quality. • Differences in perceptions of image quality directly influence reject rates. • Radiographers judge images on technical criteria. • Radiologists judge images on diagnostic criteria. • Results suggest better communication could reduce reject rates.

  16. Radiographic evaluation of hallux valgus

    International Nuclear Information System (INIS)

    Richardson, M.L.; Hansen, S.T.; Kilcoyne, R.F.

    1987-01-01

    This paper presents the common preoperative and postoperative findings in hallux valgus, a common foot disorder of multiple etiologies, which can lead to significant foot pain and deformity. Little has been published in radiologic literature about the proper initial radiographic workup and the postoperative follow-up of this very common and very treatable cause of foot pain. Besides the primary findings of varus angulation of the first metatarsal and valgus angulation of the great toe, one may also see dorsal slaying of the first metatarsal head. As increased weight is borne by the central metatarsals, they may develop hyperostosis and stress fractures. Angular deformities of the hallux sesamoid joint and lesser toes may also be seen

  17. Radiographic examination of the equine head

    International Nuclear Information System (INIS)

    Park, R.D.

    1993-01-01

    Radiographic examinations of the equine head can be performed with portable x-ray machines. The views comprising the examination depend on the area of the head being examined. With a knowledge of radiographic anatomy and radiographic signs of disease, valuable diagnostic information can be obtained from the radiographic examination. In addition, the radiographic information can also be used to develop a prognosis and determine the most appropriate therapy

  18. Rapidly processable radiographic material

    International Nuclear Information System (INIS)

    Brabandere, L.A. de; Borginon, H.A.; Pattyn, H.A.; Pollet, R.J.

    1981-01-01

    A new rapidly processable radiographic silver halide material is described for use in mammography and non-destructive testing of industrial materials. The radiographic material is used for direct exposure to penetrating radiation without the use of fluorescent-intensifying screens. It consists of a transparent support with a layer of hydrophilic colloid silver halide emulsion on one or both sides. Examples of the preparation of three different silver halide emulsions are given including the use of different chemical sensitizers. These new radiographic materials have good resistance to the formation of pressure marks in rapid processing apparatus and they have improved sensitivity for direct exposure to penetrating radiation compared to conventional radiographic emulsions. (U.K.)

  19. Radiographic features of pleural effusions in pulmonary embolism

    International Nuclear Information System (INIS)

    Bynum, L.J.; Wilson, J.E.

    1978-01-01

    A prospective analysis of 155 patients with pulmonary embolism was undertaken to describe the radiographic characteristics of associated pleural effusions and related abnormalities. Approximately one half of these patients had pleural effusions. Patients with other potential causes of effusion, such as heart failure, pneumonia, or cancer, were eliminated from further analysis. In the remaining 62 patients, radiographic evidence of pulmonary infarction accompanied pleural effusions in one half of the cases. One third of patients with parenchymal consolidation had no evidence of effusion. Atelectasis and other nonspecific radiographic abnormalities occurred in less than one fifth of the cases. Typically, pleural effusions were small and unilateral, appeared soon after symptoms of thromboembolism began, and tended to reach their maximal size very early in the course of the disorder. Pulmonary infarction was associated with larger effusions that cleared more slowly and were more often bloody in appearance on thoracentesis. Chest pain occurred in all but one patient and was a valuable diagnostic clue. Pain and pleural effusions were always ipsilateral and almost always unilateral, but neither correlated well with the presence or time course of infarction. Effusions that were delayed in onset or that enlarged late in the course were associated with recurrent pulmonary embolism or superinfection. These radiographic features may be helpful in the diagnosis and management of pulmonary embolism

  20. Risk of losing remission, low disease activity or radiographic progression in case of bDMARD discontinuation or tapering in rheumatoid arthritis: systematic analysis of the literature and meta-analysis.

    Science.gov (United States)

    Henaux, Sophie; Ruyssen-Witrand, Adeline; Cantagrel, Alain; Barnetche, Thomas; Fautrel, Bruno; Filippi, Nathalie; Lukas, Cédric; Raffeiner, Bernd; Rossini, Maurizio; Degboé, Yannick; Constantin, Arnaud

    2018-04-01

    To assess the risk of losing remission, low disease activity (LDA) or radiographic progression in the case of (1) discontinuing or (2) tapering doses of biological disease-modifying antirheumatic drugs (bDMARDs) compared with continuation of the initial treatment regimen in rheumatoid arthritis (RA) patients with remission or LDA. A systematic literature analysis was carried out through May 2017 on the PubMed, Embase, Cochrane and international congress databases, selecting controlled trials comparing bDMARDs discontinuation/tapering versus continuation in RA patients with remission or LDA. The meta-analysis assessed the risk ratio (RR) and 95% CI of losing remission or LDA and the risk of radiographic progression after (1) discontinuing and (2) tapering doses of bDMARDs versus continuing the initial treatment. The meta-analysis comparing bDMARDs discontinuation versus continuation performed on nine trials showed an increased risk of losing remission (RR (95% CI)=1.97(1.43 to 2.73), P<0.0001) or LDA (RR (95% CI)=2.24(1.52 to 3.30), P<0.0001) and an increased risk of radiographic progression (RR (95% CI)=1.09(1.02 to 1.17), P=0.01) in case of bDMARD discontinuation. The meta-analysis comparing bDMARDs tapering versus continuation performed on 11 trials showed an increased risk of losing remission (RR (95% CI)=1.23(1.06 to 1.42), P=0.006) but no increased risk of losing LDA (RR (95% CI)=1.02 (0.85 to 1.23), P=0.81) nor any increased risk of radiographic progression (RR (95% CI)=1.09(0.94 to 1.26), P=0.26) in case of bDMARD tapering. Discontinuation of bDMARDs leads to an increased risk of losing remission or LDA and radiographic progression, while tapering doses of bDMARDs does not increase the risk of relapse (LDA) or radiographic progression, even though there is an increased risk of losing remission. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted

  1. Femoral neck buttressing: a radiographic and histologic analysis

    International Nuclear Information System (INIS)

    Dixon, T.; Benjamin, J.; Lund, P.; Graham, A.; Krupinski, E.

    2000-01-01

    Objective. To examine the incidence, radiographic and histologic findings of medial femoral neck buttressing in a consecutive group of patients undergoing total hip arthroplasty.Design. Biomechanical parameters were evaluated on standard anteroposterior pelvic radiographs of 113 patients prior to hip replacement surgery. Demographic information on all patients was reviewed and histologic evaluation was performed on specimens obtained at the time of surgery.Results. The incidence of medial femoral neck buttressing was found to be 50% in a consecutive series of patients undergoing total hip arthroplasty. The incidence was slightly higher in women (56% vs 41%). Patients with buttressing had increased neck-shaft angles and smaller femoral neck diameters than were seen in patients without buttressing. Histologic evaluation demonstrated that the buttress resulted from deposition bone by the periosteum on the femoral neck in the absence of any evidence of femoral neck fracture.Conclusion. It would appear that femoral neck buttressing occurs in response to increased joint reactive forces seen at the hip being transmitted through the femoral neck. The increased joint reactive force can be related to the increased neck shaft angle seen in patients with buttressing. (orig.)

  2. Three-dimensional hindfoot alignment measurements based on biplanar radiographs: comparison with standard radiographic measurements

    International Nuclear Information System (INIS)

    Sutter, Reto; Pfirrmann, Christian W.A.; Buck, Florian M.; Espinosa, Norman

    2013-01-01

    To establish a hindfoot alignment measurement technique based on low-dose biplanar radiographs and compare with hindfoot alignment measurements on long axial view radiographs, which is the current reference standard. Long axial view radiographs and low-dose biplanar radiographs of a phantom consisting of a human foot skeleton embedded in acrylic glass (phantom A) and a plastic model of a human foot in three different hindfoot positions (phantoms B1-B3) were imaged in different foot positions (20 internal to 20 external rotation). Two independent readers measured hindfoot alignment on long axial view radiographs and performed 3D hindfoot alignment measurements based on biplanar radiographs on two different occasions. Time for three-dimensional (3D) measurements was determined. Intraclass correlation coefficients (ICC) were calculated. Hindfoot alignment measurements on long axial view radiographs were characterized by a large positional variation, with a range of 14 /13 valgus to 22 /27 varus (reader 1/2 for phantom A), whereas the range of 3D hindfoot alignment measurements was 7.3 /6.0 to 9.0 /10.5 varus (reader 1/2 for phantom A), with a mean and standard deviation of 8.1 ± 0.6/8.7 ± 1.4 respectively. Interobserver agreement was high (ICC = 0.926 for phantom A, and ICC = 0.886 for phantoms B1-B3), and agreement between different readouts was high (ICC = 0.895-0.995 for reader 1, and ICC = 0.987-0.994 for reader 2) for 3D measurements. Mean duration of 3D measurements was 84 ± 15/113 ± 15 s for reader 1/2. Three-dimensional hindfoot alignment measurements based on biplanar radiographs were independent of foot positioning during image acquisition and reader independent. In this phantom study, the 3D measurements were substantially more precise than the standard radiographic measurements. (orig.)

  3. Nurses in OR are more assertive than radiographers.

    Science.gov (United States)

    Johnson, L

    1993-01-01

    This study investigated two hypotheses: that there is a positive correlation between assertiveness and self-esteem, and that nurses rate lower than non-nurses on the constructs. A self-report survey incorporating scales for general assertiveness, situationally-specific assertiveness, global self-esteem and differentiated self-esteem was utilised. For the sample of 83 operating room nurses and 81 radiographers, correlations significant at the p scales supported the first hypothesis. Analysis of variance yielded no significant differences between the two groups on either self-esteem measures or general assertiveness, with the nurses scoring significantly higher than radiographers on the situationally-specific assertiveness scale. Findings challenge the stereotype of the 'shrinking violet' nurse. Additional analysis revealed that the power component of differentiated self-esteem had a higher correlation with global self-esteem and with both assertiveness measures than any other component. Further, the operating room nurses were significantly more power-oriented than radiographers. The pre-eminence of power in the findings suggests that assertiveness and self-esteem are issues relating to the empowerment of nurses.

  4. Radiographic test phantom for computed tomographic lung nodule analysis

    International Nuclear Information System (INIS)

    Zerhouni, E.A.

    1987-01-01

    This patent describes a method for evaluating a computed tomograph scan of a nodule in a lung of a human or non-human animal. The method comprises generating a computer tomograph of a transverse section of the animal containing lung and nodule tissue, and generating a second computer tomograph of a test phantom comprising a device which simulates the transverse section of the animal. The tissue simulating portions of the device are constructed of materials having radiographic densities substantially identical to those of the corresponding tissue in the simulated transverse section of the animal and have voids therein which simulate, in size and shape, the lung cavities in the transverse section and which contain a test reference nodule constructed of a material of predetermined radiographic density which simulates in size, shape and position within a lung cavity void of the test phantom the nodule in the transverse section of the animal and comparing the respective tomographs

  5. Radiographic positioning

    International Nuclear Information System (INIS)

    Eisenberg, R.L.; Dennis, C.A.; May, C.

    1989-01-01

    This book concentrates on the routine radiographic examinations commonly performed. It details the wide variety of examinations possible and their place in initial learning and in the radiology department as references for those occasions when an unusual examination is requested. This book provides information ranging from basic terminology to skeletal positioning to special procedures. Positions are discussed and supplemented with a picture of a patient, the resulting radiograph, and a labeled diagram. Immobilization and proper shielding of the patient are also shown

  6. A radiographic study of the position and shape of mental foramen in panoramic radiographs

    International Nuclear Information System (INIS)

    Choi, Karp Shik; Kim, Dong Youn; Sohn, Jeong Ick; Bae, Yong Chul

    1997-01-01

    The purpose of this study was to evaluate the position and shape of mental foramen in panoramic radiographs. For this study, panoramic radiographs were obtained from the 200 adults and evaluated the position and shape of mental foramen. According to various positional changes in panoramic radiographs of the patients, the author also obtained panoramic radiographs from the 100 adults and then evaluated the positional and shape changes of mental foramen. The following results were obtained : 1. Shapes of mental foramen were observed elliptical (43.3%), round or oval (42.5%), unidentified (7.5%) and diffuse (6.7%) type in descending order of frequency. 2. Horizontal position of mental foramen were most frequently observed at the 2nd premolar area (54.2%), and area between the 1st premolar and 2nd premolar (43.1%), area between the 2nd premolar and 1st molar (2.7%), and at apex (9.7%), overlap with apex (1.9%), superior of apex (0.2%) in descending order of frequency. 4. According to various positional changes in panoramic radiographs of the patients, shape changes of mental foramen were more obviously observed at the forward 10 mm and chin down 10 degree positioned panoramic radiographs, And changes of horizontal and vertical position were observed in similar to compared with normal positioned panoramic radiographs.

  7. Acute chest syndrome of sickle cell disease: radiographic and clinical analysis of 70 cases

    International Nuclear Information System (INIS)

    Martin, L.; Buonomo, C.

    1997-01-01

    Background. Acute chest syndrome (ACS) is a pulmonary illness with fever, chest pain, leukocytosis and new pulmonary opacity in a patient with sickle cell disease. It is a common reason for hospitalization in sickle cell patients, and a significant cause of mortality. The etiology of ACS is unclear. Lung or bone infarction and infection, among other possible causes, have been proposed. Objective. We reviewed the chest radiographs and medical records of 41 patients with 70 episodes of ACS and correlated the clinical and radiographic courses in an attempt to better characterize and understand the syndrome. Results. In 87 % of episodes, no identifiable etiology of ACS was found. This group of patients had a median age of 14 years and showed dramatic clinical and radiographic improvement within 24 h of therapy. In the remainder of episodes (13 %), an identifiable etiology was found, usually bacterial pneumonia. These patients were younger than the group without an identifiable etiology (median age 2 years) and had a prolonged radiographic course of illness. Conclusion. The chest radiographs of children with ACS without an identifiable etiology have an extremely typical appearance and evolution. Only in cases which do not have this typical pattern should infection be suspected as the underlying cause. (orig.). With 3 figs

  8. Preliminary analysis of doses to evaluate the image quality in radiographic examinations in veterinary radiology

    International Nuclear Information System (INIS)

    Pinto, Ana Carolina B.C.F.; Dias, Mayara T.P.; Santos, Andrea C.; Melo, Camila S.; Furquim, Tania A.C.

    2009-01-01

    This work has as objective to promote the analysis of the radiological doses and quality of the image of the technical letter used for the accomplishment of thorax and coxal radiographic examination of animals of canine and feline species. The study was accomplished in the service of Diagnosis for Image in Veterinarian Hospital of Veterinary Medicine and Zootecnia College of University of Sao Paulo, in two conventional equipment. Initially, physical features of the animals and the technique used were collected for each one of the 188 radiographic examinations of thorax and 52 examinations of coxal. The animals were placed in different groups, according to their body weight. For each group, the averages for each feature were calculated: thickness of the radiographed region, tension, electric current, time of exhibition, current product electric-time, size of the used film, presence or absence of bucky and feature of focus (narrow or thick). On the basis of the averages of group M (of lesser weights that 5kg for cats and between 10,1kg and 20kg for dogs), was executed a physical analysis of the current technical letter, using the equipment: ionization chamber (to determinate the value of kerma in air), simulator objects (representative of the thickness of the animal) and three dispositive standards of test that evaluate space resolution, resolution in low contrast and contrast-detail. The obtained images were analyzed and compared for a physicist and a radiologist medical veterinary. The results had shown that the examinations supply dose considered high for techniques used mainly for coxal. The equipment A, although to supply higher doses, presents the better images for the majority of the projections. However, the study indicates that there are not exactly reference levels, but these examinations must pass for improvement of quality of image (author)

  9. Role of Intraoperative Radiographs in the Surgical Treatment of Adolescent Idiopathic Scoliosis.

    Science.gov (United States)

    Vidal, Christophe; Ilharreborde, Brice; Queinnec, Steffen; Mazda, Keyvan

    2016-03-01

    One of the main goals of scoliosis surgery is to obtain a balanced fused spine. Although preoperative planning remains essential, intraoperative posteroanterior radiographs are the only available tool during the procedure to verify shoulder and coronal spinal balance and, if necessary, adjust the construct. The aim of this study was to quantify the direct influence of intraoperative radiographs on the surgical procedure itself during correction of adolescent idiopathic scoliosis. Retrospective analysis of prospectively collected data on a monocentric cohort of adolescent idiopathic scoliosis patients undergoing corrective surgery. A total 148 consecutive patients operated in the same department following the same validated preoperative planning method were included in this prospective radiologic study. The mean follow-up averaged 33 months. Frontal Cobb angles, T1 tilt, shoulder tilt, iliolumbar angle, and frontal balance were measured and compared on intraoperative, early postoperative, and latest follow-up radiographs. Any intraoperative modification of the correction performed after analysis of the intraoperative radiograph were recorded. The analysis of all radiologic parameters was possible in 90.5% of the cases. In 9.5% of the cases, shoulders could not be properly distinguished. Significant modifications on the upper thoracic curve to correct T1 tilt or shoulder balance were performed in 29% of the patients, and changes at the distal levels were recorded in 19%, underlining planification imperfections. On postoperative standing radiographs, the average coronal parameters were neutral, without loss of correction at follow-up. Intraoperative radiographs remain necessary to ensure compensation of the shortcomings of the modern preoperative planification method.

  10. Immobilisation-induced changes in forearm bone quantity and quality: radiographic fourier image analysis vs bone densitometry

    International Nuclear Information System (INIS)

    Moore, G.; Price, R.I.; Buck, A.M.; University of Western Australia, Nedlands, WA; Price, R.L.; University of Western Australia, Nedlands, WA; Sweetman, I.M.; Ho, S.

    1996-01-01

    Full text: Determinants of bone fracture risk include indices of bone 'quantity' such as bone mineral content (BMC, mineral mass per unit scanned bone length), plus 'environmental' (eg impact force) and 'quality' factors (Melton L.J. III et al, Bone and Min 2: 321, 1987). Bone 'quality' refers largely to the micro-geometry of bone (∼ 10-200μ), but has been less well studied because of the need for bone slices from (invasive) bone biopsies. Such studies often compare the geometry of trabecular networks (eg trabecular bone volume, trabecular number) with clinical outcomes such as fracture rates. Another (invasive) approach is to examine the two-dimensional (2-D) Fourier transform (FT) of a high-resolution radiographic image of the bone slice, since structural information is in theory encoded in the 2-D spatial-frequency (ν) spectrum. Additionally, the FT method can be applied to bone images obtained in-vivo, though superposition of information from the third dimension is a major confounding factor in their interpretation. Quantitative radiography of the ultradistal (UD) forearm permits determination of BMC (Price R et al; ACPSEM 6: 128- 137, 1983 and ACPSEM 11: 36-43, 1988), and (as a bonus) reveals a pattern (suitable for FT analysis) of the radiographic shadows of the 3-D trabecular network projected onto the image plane. Hemiplegia is associated with excessive bone loss in the paralysed (hemi) forearm, and is a model for the study of immobilisation osteoporosis. Thus, by comparing hemiplegia-induced changes in BMC and trabecular structure, derived from the same in vivo radiographic image, it is possible to compare directly the effects of disease on both bone quantity and quality, using the image of the non-paralysed (non-hemi) arm as a control. Seventy-four patients with hemiplegia of duration 3.6±3.6 (Mean±SD) years were studied cross-sectionally for radiographic BMC of their normal and paralysed UD forearms in AP view, each arm in duplicate. Methods

  11. Stress injuries of the pars interarticularis: Radiologic classification and indications for radionuclide imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pennell, R.; Maurer, A.R.; Bonakdarpour, A.

    1984-01-01

    Lumbar spine radiographs and radionuclide images were compared and correlated with clinical histories of 20 athletes with low back pain. Radiographs were classified as: Normal (Type 0); showing a healing stress fracture (an irregular lucent line) with sclerosis (Type I); as an evolving or healed stress injury with either sclerosis, narrowing, or demineralization (Type II); and as a chronic fracture showing a large lucency with well-defined margins classically referred to as spondylolysis (Type III). Patients were grouped clinically on the basis of their pain: acute onset (Group A, n = 7), acute superimposed on chronic (Group B, n = 9), and chronic pain without an acute event (Group C, n = 4). Radiographic abnormalities were present in 95% (19/20) of the patients and radionuclide studies were positive in 60% (12/20). Scintigraphy was positive most often with Type I pars abnormalities (77%, 10/13) and negative most often with Type III abnormalities (91%, 11/12). Of all positive scintigraphy 12/14 (86%) were in pts in Groups A and B (acute symptoms). The authors' findings support theories that radiographic pars abnormalities exist which correspond to stages in the healing of stress induced fractures. With acute symptoms radionuclide imaging need not be obtained if a Type I radiographic abnormality is seen. Radionuclide imaging is indicated with either Type 0, II or III radiographs to confirm or rule out recent stress injury.

  12. Stress injuries of the pars interarticularis: Radiologic classification and indications for radionuclide imaging

    International Nuclear Information System (INIS)

    Pennell, R.; Maurer, A.R.; Bonakdarpour, A.

    1984-01-01

    Lumbar spine radiographs and radionuclide images were compared and correlated with clinical histories of 20 athletes with low back pain. Radiographs were classified as: Normal (Type 0); showing a healing stress fracture (an irregular lucent line) with sclerosis (Type I); as an evolving or healed stress injury with either sclerosis, narrowing, or demineralization (Type II); and as a chronic fracture showing a large lucency with well-defined margins classically referred to as spondylolysis (Type III). Patients were grouped clinically on the basis of their pain: acute onset (Group A, n = 7), acute superimposed on chronic (Group B, n = 9), and chronic pain without an acute event (Group C, n = 4). Radiographic abnormalities were present in 95% (19/20) of the patients and radionuclide studies were positive in 60% (12/20). Scintigraphy was positive most often with Type I pars abnormalities (77%, 10/13) and negative most often with Type III abnormalities (91%, 11/12). Of all positive scintigraphy 12/14 (86%) were in pts in Groups A and B (acute symptoms). The authors' findings support theories that radiographic pars abnormalities exist which correspond to stages in the healing of stress induced fractures. With acute symptoms radionuclide imaging need not be obtained if a Type I radiographic abnormality is seen. Radionuclide imaging is indicated with either Type 0, II or III radiographs to confirm or rule out recent stress injury

  13. Radiographic analysis of body composition by computerized axial tomography

    International Nuclear Information System (INIS)

    Heymsfield, S.B.

    1986-01-01

    Radiographic methods of evaluating body composition have been applied for over five decades. A marked improvement in this approach occurred in the mid-nineteen-seventies with the introduction of computerized axial tomography. High image contrast, cross-sectional imaging and rapid computerized data processing make this technique a sophisticated clinically applicable tool. (author)

  14. Stress fractures

    International Nuclear Information System (INIS)

    Berquist, T.H.; Cooper, K.L.; Pritchard, D.J.

    1985-01-01

    The diagnosis of a stress fracture should be considered in patients presented with pain after a change in activity, especially if the activity is strenuous and the pain is in the lower extremities. Since evidence of the stress fracture may not be apparent for weeks on routine radiographs, proper use of other imaging techniques will allow an earlier diagnosis. Prompt diagnosis is especially important in the femur, where displacement may occur

  15. Evaluation of Radiographic Instability of the Trapeziometacarpal Joint in Women With Carpal Tunnel Syndrome.

    Science.gov (United States)

    Kim, Jeong Hwan; Gong, Hyun Sik; Kim, Youn Ho; Rhee, Seung Hwan; Kim, Jihyoung; Baek, Goo Hyun

    2015-07-01

    To determine whether median nerve dysfunction measured by electrophysiologic studies in carpal tunnel syndrome (CTS) is associated with thumb trapeziometacarpal (TMC) joint instability. We evaluated 71 women with CTS and 31 asymptomatic control women. Patients with generalized laxity or TMC joint osteoarthritis were excluded. We classified the electrophysiologic severity of CTS based on nerve conduction time and amplitude and assessed radiographic instability of the TMC joint based on TMC joint stress radiographs. We compared subluxation ratio between patients with CTS and controls and performed correlation analysis of the relationship between the electrophysiologic grade and subluxation ratio. Thirty-one patients were categorized into the mild CTS subgroup and 41 into the severe CTS subgroup. There was no significant difference in subluxation ratio between the control group and CTS patients or between the control group and CTS subgroup patients. Furthermore, there was no significant correlation between electrophysiologic grade and subluxation ratio. This study demonstrated that patients with CTS did not have greater radiographic TMC joint instability compared with controls, and suggests that TMC joint stability is not affected by impaired median nerve function. Further studies could investigate how to better evaluate proprioceptive function of TMC joint and whether other nerves have effects on TMC joint motor/proprioceptive function, to elucidate the relationship between neuromuscular control of the TMC joint, its stability, and its progression to osteoarthritis. Diagnostic II. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  16. Radiographic localization of unerupted mandibular anterior teeth.

    Science.gov (United States)

    Jacobs, S G

    2000-10-01

    The parallax method and the use of 2 radiographs taken at right angles to each other are the 2 methods generally used to accurately localize teeth. For the parallax method, the combination of a rotational panoramic radiograph with an occlusal radiograph is recommended. This combination involves a vertical x-ray tube shift. Three case reports are presented that illustrate: (1) how this combination can accurately localize unerupted mandibular anterior teeth, (2) how a deceptive appearance of the labiolingual position of the unerupted tooth can be produced in an occlusal radiograph, (3) how increasing the vertical angle of the tube for the occlusal radiograph makes the tube shift easier to discern, (4) why occlusal radiographs are preferable to periapical radiographs for tube shifts, and (5) how localization can also be carried out with 2 radiographs at right angles to each other, one of which is an occlusal radiograph taken with the x-ray tube directed along the long axis of the reference tooth.

  17. Producing quality radiographic images

    International Nuclear Information System (INIS)

    Cullinan, A.M.

    1987-01-01

    This book gives an overview of physics, equipment, imaging, and quality assurance in the radiology department. The chapters are laid out with generous use of subheads to allow for quick reference, Points are illustrated with clear, uncluttered line diagrams and well-produced images. The accompanying explanations are miniature lessons by themselves. Inserted at various points throughout the text are important notes that highlight key concepts. The chapter ''Image Evaluation and Application of Radiographic Principles'' present a systematic approach to evaluating radiographs and contains several sample radiographs to illustrate the points made

  18. Radiographic progession of rheumatoid arthritis

    International Nuclear Information System (INIS)

    Siozos, C.D.

    1981-01-01

    The radiographic progression of rheumatoid arthritis can be graded on a 0-IV scala. For this purpose five objective criteria are used: a) destruction, b) osteoporosis, c) narrowing of joint space, d) luxation and e) ankylosis. The grading of the radiographic progression is defined by the extent and the number of the measured alterations. The radiographic progression can be registered yearly. (orig.) [de

  19. A correlative study of the clinical and radiographic signs of periodontal disease in dogs

    International Nuclear Information System (INIS)

    Smith, M.M.; Zontine, W.J.; Willits, N.H.

    1985-01-01

    Twenty-four dogs admitted for routine teeth cleaning were selected arbitrarily to undergo a periodontal examination and a dental radiographic examination before the dental procedure. Data pertaining to the physical and radiographic manifestations of periodontal disease of 783 teeth were collected. All dogs had lesions consistent with periodontal disease, ranging from mild gingivitis and minimal plaque accumulation to severely inflamed gingiva, exuberant calculus formation, and root exposure. Of the 783 teeth examined, 153 (20%) had a pocket depth greater than or equal to 4 mm and less than or equal to 9 mm. Data regarding these teeth were subjected to statistical analysis. The clinical signs of plaque, calculus, mobility, pocket depth, and furcation were positively associated with radiographic signs of periodonta disease. The association between grossly evident gingivitis and radiographic signs of periodontal disease was not significant. Conditional probability analysis was applied to determine confidence intervals for the probability of a radiographic sign of periodontal disease occurring given that a clinical sign of periodontal disease occurs. (author)

  20. Diagnostic yield of ink-jet prints from digital radiographs for the assessment of approximal carious lesions: ROC-analysis

    International Nuclear Information System (INIS)

    Schulze, Ralf K.W.; Grimm, Stefanie; Schulze, Dirk; Voss, Kai; Keller, Hans-Peter; Wedel, Matthias

    2011-01-01

    Aims: To investigate the diagnostic quality of different quality, individually calibrated ink-jet printers for the very challenging dental radiographic task of approximal carious lesion detection. Materials and methods: A test-pattern evaluating resolution, contrast and homogeneity of the ink-jet prints was developed. 50 standardized dental radiographs each showing two neighbouring teeth in natural contact were printed on glossy paper with calibrated, randomly selected ink-jet printers (Canon S520 and iP4500, Epson Stylus Photo R2400). Printing size equalled the viewing size on a 17'' cathode-ray-tube monitor daily quality-tested according to German regulations. The true caries status was determined from serial sectioning and microscopic evaluation. 16 experienced observers evaluated the radiographs on a five-point confidence scale on all prints plus the viewing monitor with respect to the visibility of a carious lesion. A non-parametric Receiver-Operating Characteristics (ROC-) analysis was performed explicitly designed for the evaluation of readings stemming from identical samples but different modality. Significant differences are expressed by a critical ratio z exceeding ±2. Diagnostic accuracy was determined by the area (Az) underneath the ROC-curves. Results: Average Az-values ranged between 0.62 (S520 and R2400) and 0.64 (monitor, iP4500), with no significant difference between modalities (P = 0.172). Neither significant (range mean z: -0.40 (S520) and -0.11 (iP4500)) nor clinically relevant differences were found between printers and viewing monitor. Conclusions: Our results for a challenging task in dental radiography indicate that calibrated, off-the-shelf ink-jet printers are able to reproduce (dental) radiographs at quality levels sufficient for radiographic diagnosis in a typical dental working environment.

  1. Diagnostic yield of ink-jet prints from digital radiographs for the assessment of approximal carious lesions: ROC-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, Ralf K.W., E-mail: rschulze@mail.uni-mainz.de [Poliklinik fuer Zahnaerztliche Chirurgie, University Medical Center of the Johannes Gutenberg-University, Augustusplatz 2, D-55131 Mainz (Germany); Grimm, Stefanie, E-mail: StefanieGrimm@gmx.de [Poliklinik fuer Zahnaerztliche Chirurgie, University Medical Center of the Johannes Gutenberg-University, Augustusplatz 2, D-55131 Mainz (Germany); Schulze, Dirk, E-mail: dirk.schulze@uniklinik-freiburg.de [Klinik fuer Mund,- Kiefer- und Gesichtschirurgie, Sektion Roentgen, Universitaetsklinikum Freiburg, Hugstetterstr. 55, D-79106 Freiburg (Germany); Voss, Kai, E-mail: zahnarzt@drvoss.eu [Zahnaerztekammer Schleswig-Holstein, Vorstand fuer Praxisfuehrung, Westring 496, D- 24106 Kiel (Germany); Keller, Hans-Peter, E-mail: hans-peter.keller@din.de [NA Dental (NADENT) im DIN, Alexander-Wellendorff-Str. 2, D-75172 Pforzheim (Germany); Wedel, Matthias, E-mail: matthias.wedel@siemens.com [Siemens AG, Medical Solutions, Postfach 32 60, D-91050 Erlangen (Germany)

    2011-08-15

    Aims: To investigate the diagnostic quality of different quality, individually calibrated ink-jet printers for the very challenging dental radiographic task of approximal carious lesion detection. Materials and methods: A test-pattern evaluating resolution, contrast and homogeneity of the ink-jet prints was developed. 50 standardized dental radiographs each showing two neighbouring teeth in natural contact were printed on glossy paper with calibrated, randomly selected ink-jet printers (Canon S520 and iP4500, Epson Stylus Photo R2400). Printing size equalled the viewing size on a 17'' cathode-ray-tube monitor daily quality-tested according to German regulations. The true caries status was determined from serial sectioning and microscopic evaluation. 16 experienced observers evaluated the radiographs on a five-point confidence scale on all prints plus the viewing monitor with respect to the visibility of a carious lesion. A non-parametric Receiver-Operating Characteristics (ROC-) analysis was performed explicitly designed for the evaluation of readings stemming from identical samples but different modality. Significant differences are expressed by a critical ratio z exceeding {+-}2. Diagnostic accuracy was determined by the area (Az) underneath the ROC-curves. Results: Average Az-values ranged between 0.62 (S520 and R2400) and 0.64 (monitor, iP4500), with no significant difference between modalities (P = 0.172). Neither significant (range mean z: -0.40 (S520) and -0.11 (iP4500)) nor clinically relevant differences were found between printers and viewing monitor. Conclusions: Our results for a challenging task in dental radiography indicate that calibrated, off-the-shelf ink-jet printers are able to reproduce (dental) radiographs at quality levels sufficient for radiographic diagnosis in a typical dental working environment.

  2. The radiographer's role in child protection: Comparison of radiographers perceptions by use of focus groups

    International Nuclear Information System (INIS)

    Davis, Michaela; Reeves, Pauline

    2006-01-01

    The research presented in this paper is taken from a larger study whose aims were to devise a holistic picture of how diagnostic radiographers approach child protection issues and to explore how radiographers and other professionals see the role of radiographers in the chain of evidence in relation to child protection as this applies to children who present at the Imaging Department with suspected non-accidental injuries (NAI). A focus group methodology was used with focus groups being conducted in the United Kingdom and Republic of Ireland. The results indicated that both United Kingdom and Republic of Ireland radiographers agreed that they had a role in child protection; however, they identified a wide interpretation as to the extent of that role. Although radiographers in the United Kingdom and Republic of Ireland work within different legal systems there were themes identified which were common to both countries. Although radiographers referred to a duty to the child as to all patients, no radiographer specifically mentioned the system and child care law under which it is assumed they operate. This research revealed an area which would benefit from more detailed research using a wider audience. However, the study revealed a need for training in relation to possible NAI indicators and the correct procedure for documenting their suspicions and initiating an NAI referral

  3. Chesneys' radiographic imaging. 5. ed.

    International Nuclear Information System (INIS)

    Ball, J.; Price, T.

    1989-01-01

    This new edition of Chesney and Chesney: Radiographic Imaging has been completely written by two new authors. The book reflects the change in emphasis in radiology from photographic processes towards electronic imaging methods. There is new material on image intensifiers and television imaging, digital imaging and digital subtractions. Analyses of the various characteristics of, and defects in, images on radiographs, xeroradiographs and the television screen are included. The methods, equipment and materials used to record the cathode ray tube image are described and there is new material on the principles of alternative diagnostic imaging techniques such as ultrasound, computed tomography and radionuclide imaging which provide cathode ray tube images. The book is primarily for student radiographers studying for the Diploma of the College of Radiographers, but radiographers studying for postdiplomate qualifications such as the Higher Diploma (HDCR) will also find the book helpful. (author)

  4. Injuries of the trochanteric region: can analysis of radiographic indices help in prediction of recurrent osteoporotic hip fractures?

    Science.gov (United States)

    Pellegrini, Andrea; Tacci, Fabrizio; Leigheb, Massimiliano; Costantino, Cosimo; Pedrazzini, Alessio; Pedrazzi, Giuseppe; Vaienti, Enrico; Ceccarelli, Francesco; Pogliacomi, Francesco

    2017-10-18

    In a context of bone fragility, primitive and subsequent fractures are a growing problem in the industrialized countries where the mean age of the population is constantly increasing. Among the various factors that favor a fragility fracture, the most important is osteoporosis, a pathology that can be prevented through diagnostic screenings and treated by pharmacological and rehabilitative therapies. The aim of this study is to identify the subjects who are likely to have a higher risk of subsequent fractures of the trochanteric region through a retrospective radiographic evaluation of patients affected by low-energy trochanteric fractures and operated by intramedullary fixation between June 2013 and June 2015, so they can be targeted for prevention interventions. Three hundred and sixty-one patients yet alive were analyzed 2 years after surgery. Fifty-one (group 1), characterized by another contralateral trochanteric femoral fracture, were included. All subjects were retrospectively examined with the analysis of contralateral femur X-ray performed at the time of initial trauma in order to detect a condition of bone fragility and a predisposition to fractures by evaluating three radiographic indices (Singh index, Dorr's classification and Cortical Thickness Index). Patients of group 1 were compared to the other 310 patients (group 2) affected by isolated trochanteric fracture. Group 1 had all radiographic indices worse than group 2. The results observed suggest that orthopedists can use radiographic indices, in particular Cortical Thickness Index, as a valuable, simple and inexpensive screening tool for prevention of recurrent osteoporotic fractures.

  5. Interpreting radiographs. 4. The carpus

    International Nuclear Information System (INIS)

    Burguez, P.N.

    1984-01-01

    The complexity of the carpus which has three major joints, seven or eight carpal bones and five adjacent bones, each of which articulates with one or more of the carpal elements, necessitates good quality radiographs for definitive radiographic interpretation may be extremely difficult because of the disparity between radiographic changes and obvious clinical signs and, therefore, must be discussed in the light of a thorough clinical assessment

  6. A study on assessment of the length of styloid process in digital panoramic radiographs

    Directory of Open Access Journals (Sweden)

    Nikita Gupta

    2015-01-01

    Full Text Available Introduction: The styloid process (SP is an anatomical structure whose clinical importance is not well understood. Aims and Objectives: This study aimed to study the type of SP as per Langlais′ classification and to assess the feasibility of digital panoramic radiographs in measuring the length of SP. Materials and Methods: Eighty digital panoramic radiographs of patients with dental problems were retrieved from archives of our department as soft copies. The radiographs were taken using a digital panoramic system. The radiographic length of SP was measured on both sides using measurement toolbars on accompanying analysis software. The type of elongation patterns of SP was classified as per Langlais′ classification. Finally, the data were subjected to statistical analysis. Results: The average length of the left and right side SPs was 29.1882 ± 6.86 and 28.16 ± 6.44, respectively. Majority of patients were found to be asymptomatic, and Langlais′ Type I elongated SP was more common than others. Conclusion: Digital panoramic radiographs are valuable tools in early detection of elongated SP. Digital radiographs help in avoiding a misdiagnosis of tonsillar pain or pain of dental, pharyngeal, or muscular region.

  7. Improving the Quality of Radiographs in Neonatal Intensive Care Unit Utilizing Educational Interventions.

    Science.gov (United States)

    Gupta, Ashish O; Rorke, Jeanne; Abubakar, Kabir

    2015-08-01

    We aimed to develop an educational tool to improve the radiograph quality, sustain this improvement overtime, and reduce the number of repeat radiographs. A three phase quality control study was conducted at a tertiary care NICU. A retrospective data collection (phase1) revealed suboptimal radiograph quality and led to an educational intervention and development of X-ray preparation checklist (primary intervention), followed by a prospective data collection for 4 months (phase 2). At the end of phase 2, interim analysis revealed a gradual decline in radiograph quality, which prompted a more comprehensive educational session with constructive feedback to the NICU staff (secondary intervention), followed by another data collection for 6 months (phase 3). There was a significant improvement in the quality of radiographs obtained after primary educational intervention (phase 2) compared with phase 1 (p quality declined but still remained significantly better than phase 1. Secondary intervention resulted in significant improvement in radiograph quality to > 95% in all domains of image quality. No radiographs were repeated in phase 3, compared with 5.8% (16/277) in phase 1. A structured, collaborated educational intervention successfully improves the radiograph quality and decreases the need for repeat radiographs and radiation exposure in the neonates. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  8. Stress views in the radiography of scapholunate instability

    International Nuclear Information System (INIS)

    Ozcelik, Abdurrahman; Guenal, Izge; Koese, Nusret

    2005-01-01

    Aim: On the suspected carpal instabilities stress views are recommended but not often used. The present study evaluates the reliability of the dorsal and volar stress radiographs on patients with posttraumatic wrist pain. Patients and methods: Stress radiographs of the wrists were examined in 22 patients with chronic wrist pain and the results were compared with scaphoid shift test and standard and positional views. The stress examination consists of applying to the wrist dorsal and volar stresses on the hand. Results: Static scapholunate instability was diagnosed in 4 patients in whom 3 of them had positive scaphoid shift test sign as well. There were, however, 18 patients with dynamic scapholunate instability in whom the standard films were normal but dorsal stress radiography showed gap greater than 3 mm between the scaphoid and lunate. Conclusion: Stress tests may provide considerable information in the evaluation of a patient who has a painful wrist in whom routine and special views do not demonstrate scapholunate dissociation

  9. Radiographic testing at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Bossi, R.H.

    1982-01-01

    Radiographic testing is a nondestructive inspection technique which uses penetrating radiation. The Nondestructive Evaluation (NDE) Section at Lawrence Livermore National Laboratory has a broad spectrum of equipment and techniques for radiographic testing. These resources include low-energy vacuum systems, low- and mid-energy cabinet and cell radiographic systems, high-energy linear accelerators, portable x-ray machines and radioisotopes for radiographic inspections. For diagnostic testing the NDE Section also has real-time and flash radiographic equipment

  10. Interpretation and digestion of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    Radiography digestion is final test for the radiography to make sure that radiograph produced will inspect their quality of the image before its interpreted. This level is critical level where if there is a mistake, all of the radiography work done before will be unaccepted. So as mention earlier, it can waste time, cost and more worst it can make the production must shut down. So, this step, level two radiographers or interpreter must evaluate the radiograph carefully. For this purpose, digestion room and densitometer must used. Of course all the procedure must follow the specification that mentioned in document. There are several needs must fill before we can say the radiograph is corrected or not like the location of penetrameter, number of penetrameter that showed, the degree of density of film, and usually there is no problem in this step and the radiograph can go to interpretation and evaluation step as will mentioned in next chapter.

  11. Histopathological, Microbiological, and Radiographic Analysis of Antimicrobial Photodynamic Therapy for the Treatment of Teeth with Apical Periodontitis: A Study in Rats' Molars.

    Science.gov (United States)

    Trindade, Alessandra Cesar; de Figueiredo, José Antônio Poli; de Oliveira, Sílvia Dias; Barth Junior, Valdir Cristóvão; Gallo, Stephanie Wagner; Follmann, Carina; Wolle, Carlos Frederico Brilhante; Steier, Liviu; Morgental, Renata Dornelles; Weber, João Batista Blessmann

    2017-07-01

    The aim of this study was to evaluate in vivo, by histological and radiographic analysis, the response of apical tissues of rats' teeth with experimentally induced apical periodontitis, after one- and two-session endodontic treatment with and without photodynamic therapy (PDT). A microbiological analysis was also performed to verify bacterial reduction after each treatment. Studies carried out in recent years highlighted the antibacterial potential of PDT when associated with conventional endodontic therapy in vitro. Although the antimicrobial effect of PDT is well-established, tissue response to PDT in teeth with apical periodontitis lacks studies. Thirty-two rats' root canals were assigned to four groups: one session/PDT-[chemomechanical preparation (CMP)+root canal filling (RCF)]; two sessions/PDT- [CMP+calcium hydroxide (CH) for 14 days+RCF]; one session/PDT+ [CMP+PDT+RCF], and two sessions/PDT+ [CMP+PDT+CH for 14 days+RCF]. For microbiological evaluation, samples were collected before and after proposed treatments. For radiographic and histological analysis, the animals were euthanized after 28 days and the mandibles surgically removed. PDT associated with conventional endodontic therapy was able to promote significant bacterial reduction in root canals with induced apical periodontitis, but this reduction was not significantly different to conventional endodontic therapy alone. Although radiographic evaluation showed no significant differences, histological analysis showed lower scores for neutrophils/eosinophils in PDT-treated groups and macrophages/giant cells in CH groups. The use of low-level laser as light source did not promote major improvement on radiographic and histological repair, but since the number of inflammatory cells slightly decreased, it may optimize repair by modulating inflammatory process. PDT may be indicated as an adjunct to conventional endodontic therapy for teeth with apical periodontitis, in association with an interappointment

  12. Reporting by radiographers: a policy and practice guide

    International Nuclear Information System (INIS)

    Paterson, Audrey M.; Price, Richard C.; Thomas, Adrian; Nuttall, Lorraine

    2004-01-01

    Reporting by radiographers and other non-medical staff has developed considerably in the past decade, and especially so since the College of Radiographers published its vision paper on reporting by radiographers, in 1997. It was felt necessary, therefore, to develop guidance to assist radiographers and others undertaking radiographic reporting. The guidance provided includes guidance on planning and implementing a reporting service using reporting radiographers; the education, continuing education and support required by reporting radiographers; quality and standards related to reporting; and the nature of a report. Broader issues that will need to be addressed as reporting by radiographers becomes the norm are also raised

  13. Stress urinary incontinence in the female

    International Nuclear Information System (INIS)

    Baldelli, S.; Giovagnoni, A.; Bichi Secchi, E.; Argaglia, G.; Caraceni, E.; Muzzonigro, G.

    1988-01-01

    This work is aimed at demonstrating the validity of conventional radiological procedures, correlated with urodynamics, in the study of female urinary stress incontinence. In a study population of 110 patients with a clinical-urodynamic diagnosis of stress incontinence, radiological evaluation was performed by means of retrograde cystography, bead chain cystourethrography, and voiding cystourethrography. Radiographic findings were correlated with urodynamic data, and in particular with urethral pressure profile (fuctional lenght of the urethra, maximum closing pressure, maximum urethral pressure). In all patients the posterior urethro-vesical angle values were higher than 100 grade centigrades; moreover, a correlation was proven to exist between an increase in the angle of front urethral inclination, the lowering and mobility of the urethro-vesical junction, and the severeness of urodynamic findings. Furtheremore, in the different stages of urodynamic severeness, urethral funnelling was most frequent, and the flattening of the posterior vesical floor in voiding cystourethrography. The high reliability of the radiographic findings, although obtained by means of conventional techniques, and the variability of the morphodynamic results confirm the importance of a combined radiographic and urodynamic study in the evaluation of stress incontinence

  14. Pulp polyp - A periapical lesion: Radiographic observational study

    Directory of Open Access Journals (Sweden)

    Kandagal V Suresh

    2015-01-01

    Full Text Available Introduction: Pulp polyp (PP is a chronic hyperplastic condition resulting in formation of granulation tissue and proliferative mass. The radiographic appearance of PP has innumerable presentations. Diagnosing and treatment planning of periapical lesions, heavily relies on the radiographic changes surrounding the root structures. Objective: To evaluate different radiographic periapical changes in clinically detected PP patients. Materials and Methods: Patients reporting to Department of Oral Medicine and Radiology and who were clinically diagnosed with PP by an oral diagnostician were subjected to radiographic examination. Digital intraoral periapical radiographs of 50 patients with PP were taken. Various periapical changes in the digital radiographs were recorded by a skilled oral radiologist. The data obtained was subjected to statistical analysis using SPSS ver 17.0 and P-value was set at <0.05 as significant. Result: Periapical changes like periodontal space widening (PDLW, loss of lamina dura, periapical abscess, periapical granuloma, hypercementosis, condensing osteitis and root resorption were noted. Periodontal space widening was seen in all patients (100%, loss of lamina dura was noted in 72%, periapical rarefying osteitis in 56%, condensing osteitis in 8%, hypercementosis, periapical granuloma, and root resorption were seen in 4% of PP patients. Majority of PP were asymptomatic (66%. Pulp polyp was commonly seen in mandibular first molar followed by mandibular second molar and maxillary first molar. Statistically significant difference was noticed between periapical changes in PP patients (P value <0.0001. All PP patients showed definite periapical changes suggesting it to be a periapical lesion. Conclusion: Pulp polyp is confined to the pulpal portion of the tooth which, may or may not cause changes in periapical region. The results of the present study showed that majority of the PP patients were associated with definite periapical

  15. An observational study based on the interaction between the paediatric patient and radiographer

    International Nuclear Information System (INIS)

    Harding, J.; Davis, M.

    2015-01-01

    Background: The practice of paediatric radiography requires a completely different skill set to that of adult radiography. Often, obtaining a paediatric patient's cooperation is the most difficult aspect of the role. Ensuring that a child cooperates for the examination can make positioning easier, thereby potentially providing a more diagnostic image. Aim: The aim of this study was to observe the interaction between the paediatric patient and the radiographer and to uncover techniques used by the radiographer to help alleviate any fear or stress that the child might have had. Method: A direct observational method was conducted, after both the radiographer and the child's guardians provided full written consent. The actions of the radiographer and resultant reactions from the child were recorded on an observational checklist designed for paediatric examinations. Results: Seventy-nine patients aged between three months to fifteen years and thirteen radiographers with no specific paediatric training other than experience were observed. Examinations observed included lower limb, upper limb, pelvis, abdomen and chest projections. The data gathered were the result of radiographer actions when interacting with both happy and sad children. Conclusions: Successful methods of alleviating a child's fear and anxiety whilst in the X-ray room included the use of child friendly equipment such as colourful lead protection and posters on the wall, a simple explanation of what the equipment is before moving it, offering rewards such as stickers and praise and showing the child their image after the examination. When time was short and the workload was high, it was observed that radiographers were less likely to spend time calming the child down and instead were more focused on completing the examination as quickly as possible. - Highlights: • Seventy-nine patients and thirteen radiographers were observed in this study. • The use of child-friendly equipment and

  16. 14 CFR 33.62 - Stress analysis.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Stress analysis. 33.62 Section 33.62... STANDARDS: AIRCRAFT ENGINES Design and Construction; Turbine Aircraft Engines § 33.62 Stress analysis. A stress analysis must be performed on each turbine engine showing the design safety margin of each turbine...

  17. Digital radiographic assessment of coronary flow reserve

    International Nuclear Information System (INIS)

    Vogel, R.A.

    1985-01-01

    A method for measuring relative changes in regional blood flow using digital radiographic enhancement of selective coronary arteriography. Coronary flow reserve is measured in individual arterial distributions using the washin ratio of contrast appearance time under baseline and hyperemic conditions. Information is quantitatively presented in functional (parametric) image format. These images, termed contrast medium appearance pictures (CMAP), depict the transit of contrast through the arterial, myocardial and early venous stages. This process can be divided into three general phases: data acquisition, CMAP formation and CMAP analysis. The technique has evolved over its development period from a cine film-based technology which required substantial processing time to a real-time digital radiographic technique

  18. Radiographic findings of primary lung cancer with delayed detection on chest radiographs

    International Nuclear Information System (INIS)

    Kim, Young Min; Kim, Jin Hwan; Jung, Bin Young; Jun, Kwang Jin; Jeong, Ki Ho; Kim, Ju Ok; Kim, Sun Young; Yang, Chang Kyu

    1999-01-01

    To analyze the causes of delayed detection of lung cancer on chest radiographs. We retrospectively reviewed 105 cases in which an initial diagnosis of lung cancer, based on an examination of plain radiographs, had been missed or misinterpreted. All occurred between October 1993 and April 1997. We reviewed the initial chest radiographs and compared the features noted with those seen on later chest radiographs and computed tomographic (CT) images. Undetected lung cancer was identified in 56 patients (56/105, 53.3%) It had been hidden by superimposed structures (41, 73.2%), overlapped by combined benign diseases (12, 21.4%), or the nodules were subtle (3, 5.4%). Of the 41 lung cancers hidden by a superimposed structure, the central type accounted for 29 (70.7%) and the peripheral type for 12 (29.3%). The 29 central type had been hidden by the left hilum (n=15), the right hilum (n=10), the heart (n=3), or a rib (n=1). The twelve peripheral type were hidden by a rib (n=7), the heart (n=2), the diaphragm (n=2), or the left hilum (n=1). Of the 12 lung cancers overlapped by combined benign diseases, pulmonary tuberculosis (n=6), pleural effusion (n=4), congestive heart failure (n=1), and diffuse interstitial lung disease (n=1) were present at the time of interpretation. The misinterpreted lung cancers were identified in 49 patients (49/105, 46.7%) and were seen to be combined with benign disease (16, 32.6%), or as obstructive pneumonia without a central mass (15, 30.6%), air-space consolidation (7, 14.3%), cavity (7, 14.3%), double lesion (2, 4.1%), or young age below 26 years (2,4.1%). Of the 16 lung cancers misinterpreted as combined disease, pulmonary tuberculosis (n=14) and pleural disease (n=2) had been initially diagnosed. Most commonly, lung cancer was missed or misinterpreted because it was hidden by a normal structure or combined with a benign disease. Perceptual errors can be reduced by appropriate techniques and the scrutiny of trouble spots such as the

  19. Sliding-screw plate fixation of proximal femoral fractures: Radiographic assessment

    Energy Technology Data Exchange (ETDEWEB)

    Sartoris, D.J.; Resnick, D.; Kerr, R.; Goergen, T.

    1985-07-01

    The sliding compression screw-sideplate combination is currently the most widely employed device for internal fixation of stable and unstable intertrochanteric fractures of the femur. The normal and abnormal radiographic appearances of this device in the immediate post-operative period are discussed. Potential long-term complications including mal- or non-union, intra-articular penetration, metal failure, rotation of the proximal fracture fragment, disengagement, trochanteric bursitis, leg length discrepancy, delayed cervical stress fracture, and ischemic necrosis are reviewed.

  20. Radiographic cup anteversion measurement corrected from pelvic tilt.

    Science.gov (United States)

    Wang, Liao; Thoreson, Andrew R; Trousdale, Robert T; Morrey, Bernard F; Dai, Kerong; An, Kai-Nan

    2017-11-01

    The purpose of this study was to develop a novel technique to improve the accuracy of radiographic cup anteversion measurement by correcting the influence of pelvic tilt. Ninety virtual total hip arthroplasties were simulated from computed tomography data of 6 patients with 15 predetermined cup orientations. For each simulated implantation, anteroposterior (AP) virtual pelvic radiographs were generated for 11 predetermined pelvic tilts. A linear regression model was created to capture the relationship between radiographic cup anteversion angle error measured on AP pelvic radiographs and pelvic tilt. Overall, nine hundred and ninety virtual AP pelvic radiographs were measured, and 90 linear regression models were created. Pearson's correlation analyses confirmed a strong correlation between the errors of conventional radiographic cup anteversion angle measured on AP pelvic radiographs and the magnitude of pelvic tilt (P cup anteversion angle from the influence of pelvic tilt. The current method proposes to measure the pelvic tilt on a lateral radiograph, and to use it as a correction for the radiographic cup anteversion measurement on an AP pelvic radiograph. Thus, both AP and lateral pelvic radiographs are required for the measurement of pelvic posture-integrated cup anteversion. Compared with conventional radiographic cup anteversion, the errors of pelvic posture-integrated radiographic cup anteversion were reduced from 10.03 (SD = 5.13) degrees to 2.53 (SD = 1.33) degrees. Pelvic posture-integrated cup anteversion measurement improves the accuracy of radiographic cup anteversion measurement, which shows the potential of further clarifying the etiology of postoperative instability based on planar radiographs. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  1. Radiographers' commitment to continuing professional development: A single-centre evaluation

    International Nuclear Information System (INIS)

    Stevens, Barry J.

    2016-01-01

    Purpose: This study aimed to examine radiographers' commitment to continuing professional development (CPD), and to ascertain what types of activities are preferred so a model for provision of departmental activities could be developed. Methods: An online survey was used to obtain information from all departmental radiographers regarding their commitment to CPD. Statistical analysis, using Spearman's Rho and Chi-Square test, was utilised to investigate any associations. Results: All radiographers (n = 57) were invited via email. A response rate of 67% (n = 38) prevailed. Radiographers feel CPD is important and a positive correlation existed with feelings regarding compulsory CPD (r value = .718, P value = .001). Thirty-four percent had logged the SOR-recommended twelve or more pieces of CPD in the last 2 years. One to three hours a month is the preferred amount of own time radiographers are willing to dedicate. Negative correlations exist between the amount of own time radiographers are willing to commit to CPD activities and their feelings regarding compulsory CPD (r value = −.419, P value = .009), and HCPC audit (r value = −.509, P value .001). Conclusion: Although radiographers recognise the importance of CPD many spend less than four hours of their own time a month on CPD. Departmental activities should be free, short lasting, lunchtime presentations with theory presentation that encourage interaction and discussion with inclusion of practical elements. Further research investigating the barriers that prevent radiographers from partaking in CPD and the causes for insufficient CPD records is recommended. - Highlights: • The large majority of radiographers feel CPD is important or very important to them. • The majority had positive opinions regarding compulsory CPD and HCPC audit. • 50% of radiographers commit less than 4 h of their own time to CPD. • As radiographers get older they log less CPD and commit less time to CPD.

  2. Radiographic examination for successful dental implant

    International Nuclear Information System (INIS)

    Lee, Sam Sun; Choi, Soon Chul

    2005-01-01

    Recently implant has become an important field in dental clinic. Radiographic examination of pre- and post-operation is essential for successful treatment. Clinicians should have knowledge about the purpose of the radiographic examination, suitable imaging modality for the cases, anatomic landmarks of tooth and jaw bone, advantage and limitation of panoramic radiographic examination for implant, principle and interpretation of cross-sectional imaging, bone mineral density, post-operative radiographic examination. This paper will be helpful to get above information for dentists who want to do dental implant successfully.

  3. Validity of radiographic assessment of ankylosis

    International Nuclear Information System (INIS)

    Stenvik, A.; Beyer-Olsen, E.; Aabyholm, F.; Haanaes, H.R.; Gerner, N.W.

    1990-01-01

    The accuracy and sensitivity of radiographic assessments of reactive processes in dental tissues were evaluated by comparison of radiographs and histologic sections. Experimental lesions inflicted on the roots of 10 monkey incisors had been observed by means of serially obtained radiographs over a period of 315 to 370 days. The material was used for evaluation of radiographic assessment of ankylosis. For comparative purposes, assessment of the experimental lesion penetrating to the pulp and periapical radiolucency was added. True and falsely positive or negative recordings formed the basis for calculation of the accuracy and sensitivity of the radiographic assessment. The sensitivity, or the obsevers ability to detect the actual changes, was high for pulp penetration, intermediate for inflammation, and low for ankylosis. 6 refs., 3 figs., 2 tabs

  4. Texture analysis of trabecular bone using conventional radiographs: medical imaging and osteoporosis

    International Nuclear Information System (INIS)

    Karunanithi, R.; Panicker, T.M.R.; Paul Korath, M.; Jagadeesan, K.; Ganesan, S.

    2008-01-01

    Osteoporosis is characterized by reduced bone mass, microstructural deterioration with advancing age, and an increase in fracture risk. The accurate clinical assessment of bone strength and fracture risk is important for management of bone loss diseases such as osteoporosis risk. From a clinical point of view, microarchitecture is an interesting aspect to study and define patterns of bone alterations with aging and pathology. Microarchitecture seems to be a determinant of bone fragility independent of bone density. Moreover, bone microarchitecture seems to be important to understand the mechanisms of bone fragility independent of bone density. Moreover bone microarchitecture seems to be important to understand the mechanisms of bone fragility as well as the action of the drugs used to prevent osteoporotic fractures. In the case of osteoporosis the bone texture of the trabecular network as it appears on the plain radiographs can be quantified by applying image processing tools. Among the factors conditioning bone strength and osteoporotic fractures, bone mineral density is the most important and the best studied. Though, other factors also play a role: macroarchitecture of bones, cortical thickness, quality of bone crystal and of collagen network and trabecular microarchitecture. The microarchitecture plays a major role, and is an aspect of the definition of osteoporosis. Therefore, it would be very helpful if these alterations could be measured in addition to bone mineral density with noninvasive techniques, such as radiographs, and to assess the status of the bone by texture analysis

  5. Reliability and relationship of radiographic measurements in hallux valgus.

    Science.gov (United States)

    Lee, Kyoung Min; Ahn, Soyeon; Chung, Chin Youb; Sung, Ki Hyuk; Park, Moon Seok

    2012-09-01

    Although various radiographic measurements have been developed and used for evaluating hallux valgus, not all are universally believed to be necessary and their relationships have not been clearly established. Determining which are related could provide some insight into which might be useful and which would not. We investigated the reliability of eight radiographic measurements used to evaluate hallux valgus, and determined which were correlated and which predicted the hallux valgus angle. We determined eight radiographic indices for 732 patients (mean age, 51 years; SD, 17 years; 107 males and 625 females) with hallux valgus: hallux valgus angle, intermetatarsal angle, hallux interphalangeal angle, distal metatarsal articular angle, proximal phalangeal articular angle, simplified metatarsus adductus angle, first metatarsal protrusion distance, and sesamoid rotation angle. Intraobserver and interobserver reliabilities of each radiographic measurement were analyzed on 36 feet from 36 randomly selected patients. Correlations among the radiographic measurements were analyzed. Radiographic measurements predicting hallux valgus angle were evaluated using multiple regression analysis. Hallux valgus angle had the highest reliability, whereas the distal metatarsal articular angle and simplified metatarsus adductus angle had the lowest. Distal metatarsal articular angle, intermetatarsal angle, and sesamoid rotation angle had the highest correlations with hallux valgus angle. Distal metatarsal articular angle correlated with sesamoid rotation angle. The intermetatarsal angle, interphalangeal angle, distal metatarsal articular angle, first metatarsal protrusion distance, sesamoid rotation angle, and metatarsus adductus angle predicted the hallux valgus angle. We suggest using hallux valgus angle, intermetatarsal angle, interphalangeal angle, sesamoid rotation angle, and first metatarsal protrusion distance considering their reliability and prediction of the deformity.

  6. Stress: a concept analysis.

    Science.gov (United States)

    Goodnite, Patricia M

    2014-01-01

    To analyze the concept of stress and provide an operational definition of stress. Literature review revealed that stress is a commonly used, but often ambiguous, term. Findings supported a definition of stress entailing an individual's perception of a stimulus as overwhelming, which in turn elicits a measurable response resulting in a transformed state. This analysis adopts a dynamic definition of stress that may serve to encourage communication, promote reflection, and enhance concept understanding. This definition may provide direction for future work, as well as enhance efforts to serve patients affected by stress. © 2013 Wiley Periodicals, Inc.

  7. Assessment of medial elbow laxity by gravity stress radiography: comparison of valgus stress radiography with gravity and a Telos stress device.

    Science.gov (United States)

    Harada, Mikio; Takahara, Masatoshi; Maruyama, Masahiro; Nemoto, Tadanobu; Koseki, Kazuhiko; Kato, Yoshihiro

    2014-04-01

    Valgus instability was reported to be higher with the elbow in 60° of flexion, rather than in 30° of flexion, although there are no studies using valgus stress radiography by gravity (gravity radiography) with the elbow in 60° of flexion. Fifty-seven patients with medial elbow pain participated. For both elbows, valgus stress radiography by use of a Telos device (Telos radiography) and gravity radiography, with the elbow in 60° of flexion, were performed for the assessment of medial elbow laxity. In both radiographs, the medial elbow joint space (MJS) on the affected side was compared with that on the opposite side, and the increase in the MJS on the affected side was assessed. For the Telos radiographs, the mean MJS was 4.7 mm on the affected side and 4.0 mm on the opposite side, with the mean increase in the MJS on the affected side being 0.7 mm. For the gravity radiographs, the mean MJS was 5.0 mm on the affected side and 4.2 mm on the opposite side, with the mean increase in the MJS on the affected side being 0.8 mm. There were significant correlations between the Telos and gravity radiographs in the MJS on the affected side, the MJS on the opposite side, and the increase in the MJS on the affected side (respectively, P gravity radiographs. Gravity radiography is useful for assessment of medial elbow laxity, similar to Telos radiography. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  8. Radiographic testing - optimum radiographs of plastics and composite materials with dosimeter control

    International Nuclear Information System (INIS)

    Kuster, J.

    1978-01-01

    In view of great differencies in X-ray transmission it is more difficult to get optimum radiographs of plastics and especially of reinforced plastics than for example of metals. A procedure will be reported how to get with little effort optimum radiographs especially also in the range of long wavelength radiation corresponding 10 to 25 kV.P. (orig.) [de

  9. 21 CFR 892.1840 - Radiographic film.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film. 892.1840 Section 892.1840 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1840 Radiographic film. (a) Identification. Radiographic film is a device that consists of a thin sheet of radiotransparent material coated on one or both...

  10. Variability amongst radiographers in the categorization of clinical acceptability for digital trauma radiography

    Science.gov (United States)

    Decoster, Robin; Toomey, Rachel; Smits, Dirk; Mol, Harrie; Verhelle, Filip; Butler, Marie-Louise

    2016-03-01

    Introduction: Radiographers evaluate anatomical structures to judge clinical acceptability of a radiograph. Whether a radiograph is deemed acceptable for diagnosis or not depends on the individual decision of the radiographer. Individual decisions cause variation in the accepted image quality. To minimise these variations definitions of acceptability, such as in RadLex, were developed. On which criteria radiographers attribute a RadLex categories to radiographs is unknown. Insight into these criteria helps to further optimise definitions and reduce variability in acceptance between radiographers. Therefore, this work aims the evaluation of the correlation between the RadLex classification and the evaluation of anatomical structures, using a Visual Grading Analysis (VGA) Methods: Four radiographers evaluated the visibility of five anatomical structures of 25 lateral cervical spine radiographs on a secondary class display with a VGA. They judged clinical acceptability of each radiograph using RadLex. Relations between VGAS and RadLex category were analysed with Kendall's Tau correlation and Nagelkerke pseudo-R². Results: The overall VGA score (VGAS) and the RadLex score correlate (rτ= 0.62, pscore. The reproduction of spinous processes (rτ=0.67, pscore. Conclusion: RadLex scores and VGAS correlate positively, strongly and significantly. The predictive value of bony structures may support the use of these in the judgement of clinical acceptability. Considerable inter-observer variations in the VGAS within a certain RadLex category, suggest that observers use of observer specific cut-off values.

  11. Diagnostic value of chest radiographs in bedridden patients suspected of having pneumonia.

    Science.gov (United States)

    Esayag, Yaacov; Nikitin, Irina; Bar-Ziv, Jacob; Cytter, Ruth; Hadas-Halpern, Irith; Zalut, Todd; Yinnon, Amos M

    2010-01-01

    To assess the diagnostic value of the chest radiograph for the diagnosis of pneumonia in bedridden patients, using non-contrast-enhanced high-resolution chest computed tomography (CT) as the gold standard. We prospectively evaluated bedridden patients hospitalized with moderate to high clinical probability of pneumonia. Chest radiographs were interpreted in a blinded fashion by 3 observers and classified as definite, normal, or uncertain for pneumonia. Chest CT was obtained within 12 hours of chest radiograph. We applied Bayesian analysis to assess the accuracy of chest radiograph in the diagnosis of pneumonia. In a 5-month period, 58 patients were evaluated, 31 (53%) were female. Their chest radiographs were interpreted as negative, uncertain, or positive for pneumonia in 31 (53%), 15 (26%), and 12 (21%) patients, respectively, while CT confirmed pneumonia in 11 (35%), 10 (67%), and in 10 (83%). The sensitivity of the chest radiograph to diagnose pneumonia was 65%, the specificity was 93%, the positive and negative predictive values were, respectively, 83% and 65%, while the overall accuracy was 69% (95% confidence interval, 50%-79%). In bedridden patients with suspected pneumonia, a normal chest radiograph does not rule out the diagnosis, hence, a chest CT scan might provide valuable diagnostic information. Copyright 2010 Elsevier Inc. All rights reserved.

  12. Independent radiographic prognostic factors in patients with hospital-treated community-acquired pneumonia

    International Nuclear Information System (INIS)

    Wilhelm, K.; Textor, J.; Schild, H.; Ewig, S.; Luederitz, B.; Krollmann, G.

    1999-01-01

    Purpose: To evaluate the independent prognostic impact of the chest radiograph for mortality from community-acquired pneumonia requiring hospitalization. Methods: Chest radiographs of 67 patients with hospital-treated community-acquired pneumonia were analyzed with regard to the prognostic implications of radiographic patterns, extent and density of infiltrates, and its evolution during treatment. Results: Non-survivors had a significantly higher extent of infiltrates (p=0.008), density of infiltrates (p=0.05), and radiographic spread during follow-up within 48-72 hours (p=0.0001). In multivariate analysis, persistent or progressive infiltrates were associated with a 47fold increase, and persistent or progressive density of infiltrates with an 18fold increase in risk of mortality. The presence of both parameters could correctly predict 96% of survivors and 90% of non-survivors. Conclusions: The chest radiograph is an independent predictor of the severity of pneumonia. Both persistent or progressive infiltrates and persistent or progressive density of infiltrates are independently associated with mortality from community-acquired pneumonia. (orig.) [de

  13. Reproductive health of male radiographers

    International Nuclear Information System (INIS)

    Shakhatreh, Farouk M.

    2001-01-01

    To compare certain reproductive health problems reported in 2 groups of males, one of which was exposed to x-ray radiation (radiographers) and the other group that was not exposed to x-ray radiation. The reproductive health problems were miscarriage, congenital anomalies, still births and infertility. Two groups of men were selected (90 in each group). The first group consisted of radiographers and the other groups consisted of men not exposed to x-ray radiation. The 2 groups were matched for age and source. Relative risk, attributable risk percentage and level of significance were calculated. Incidence rate of reproductive health problems was increasing with the increase in duration of exposure to x-ray radiation ranging between 17% (for those exposed for 1-5 years) to 91% (for those exposed for more than 15 years). There were significant associations between exposure to radiation and miscarriage (relative risk = 1.67, attributable risk percentage = 40%), congenital anomalies (relative risk = 10, attributable risk percentage 90%), still birth (relative risk = 7, attributable risk percentage = 86%), and infertility (relative risk = 4.5, attributable risk = 78%). The incidence rates of reproductive health problems reported by male radiographers were significantly higher than that reported by the non exposed group and higher than the incidence rates reported in community-based studies in Jordan. The incidence rates of fetal death (miscarriage and stillbirth together) and infertility reported by our radiographers were higher than had been reported by the British radiographers. An immediate plan of action is needed to protect our radiographers. Further studies are needed in this field taking into account all extraneous variables that may affect the reproductive health of radiographers. (author)

  14. Comparison of codes and standards for radiographic inspection

    International Nuclear Information System (INIS)

    Bingoeldag, M. M.; Aksu, M.; Akguen, A. F.

    1995-01-01

    This report compares the procedurel requirements and acceptance criteria for radiographic inspections specified in the relevant national and international codes and standards. In particular, detailed analysis of inspection conditions such as exposure arrangements, and contrast requirements are given

  15. Accuracy of radiographer reporting of paediatric brain CT

    International Nuclear Information System (INIS)

    Brandt, Andrew; Louw, Brand; Dekker, Gerrit; Andronikou, Savvas; Wieselthaler, Nicki; Kilborn, Tracy; Bertelsman, Jessica; Dreyer, Catherine

    2007-01-01

    Radiographer reporting has been studied for plain films and for ultrasonography, but not in paediatric brain CT in the emergency setting. To study the accuracy of radiographer reporting in paediatric brain CT. We prospectively collected 100 paediatric brain CT examinations. Films were read from hard copies using a prescribed tick sheet. Radiographers with 12 years' and 3 years' experience, respectively, were blinded to the history and were not trained in diagnostic film interpretation. The radiographers' results were compared with those of a consultant radiologist. Three categories were defined: abnormal scans, significant abnormalities and insignificant abnormalities. Both radiographers had an accuracy of 89.5% in reading a scan correctly as abnormal, and radiographer 1 had a sensitivity of 87.8% and radiographer 2 a sensitivity of 96%. Radiographer 1 had an accuracy in detecting a significant abnormality of 75% and radiographer 2 an accuracy of 48.6%, and the sensitivities for this category were 61.6% and 52.9%, respectively. Results for detecting the insignificant abnormalities were poorer. Selected radiographers could play an effective screening role, but lacking the sensitivity required for detecting significant abnormality, they could not be the final diagnostician. We recommend that the study be repeated after both radiographers have received formal training in interpretation of paediatric brain CT. (orig.)

  16. Detecting objects in radiographs for homeland security

    Science.gov (United States)

    Prasad, Lakshman; Snyder, Hans

    2005-05-01

    We present a general scheme for segmenting a radiographic image into polygons that correspond to visual features. This decomposition provides a vectorized representation that is a high-level description of the image. The polygons correspond to objects or object parts present in the image. This characterization of radiographs allows the direct application of several shape recognition algorithms to identify objects. In this paper we describe the use of constrained Delaunay triangulations as a uniform foundational tool to achieve multiple visual tasks, namely image segmentation, shape decomposition, and parts-based shape matching. Shape decomposition yields parts that serve as tokens representing local shape characteristics. Parts-based shape matching enables the recognition of objects in the presence of occlusions, which commonly occur in radiographs. The polygonal representation of image features affords the efficient design and application of sophisticated geometric filtering methods to detect large-scale structural properties of objects in images. Finally, the representation of radiographs via polygons results in significant reduction of image file sizes and permits the scalable graphical representation of images, along with annotations of detected objects, in the SVG (scalable vector graphics) format that is proposed by the world wide web consortium (W3C). This is a textual representation that can be compressed and encrypted for efficient and secure transmission of information over wireless channels and on the Internet. In particular, our methods described here provide an algorithmic framework for developing image analysis tools for screening cargo at ports of entry for homeland security.

  17. Improving Continuing Professional Development opportunities for radiographers: A single centre evaluation

    International Nuclear Information System (INIS)

    Stevens, Barry J.; Wade, Demetri

    2017-01-01

    Purpose: This study aimed to identify current barriers to CPD and generate ideas for strategies to overcome these issues. Further aims were to gather an overview of respondents' understanding and opinions of CPD. Methods: An online survey was used to acquire information from departmental band 5 and band 6 radiographers. Descriptive statistical analysis and thematic analysis were performed to understand demographics and individuals' behaviours and experiences. Findings: Radiographers (n = 33) were sent an invitation via email providing a response rate of 75.8% (n = 25), with 20 females (80%) and 5 males (20%). 52% (n = 13) dedicate less than three hours a month. Participants highlighted time restraint as their biggest barrier to CPD. They also indicated a reluctance to use their own time to undertake work-related learning, despite exhibiting positive attitudes towards CPD. Radiographers see CPD as a vital and necessary, career-long learning process and they recognise the impacts on service provision. The notion of dedicated study time was unanimously suggested as the best approach to increase commitment to CPD. Conclusion: Radiographers demonstrated positive opinions of CPD, yet it was evident that many are not undertaking activities during their own time and it was acknowledged that opportunities during work time are limited. The provision of study time in work was suggested as an approach to improve radiographer's opportunities to complete CPD. Training sessions underlining the necessity of CPD in maintaining registration, what constitutes CPD and reinforcement of the benefits of systematic recording of CPD should be provided. - Highlights: • 80% believe they do not do enough CPD, 52% dedicate less than 3 h a month. • Radiographers are aware of the positive impact of learning on development. • Training should be given as a strategy to address radiographers' CPD inactivity. • The overarching theme relating to barriers to CPD is

  18. Chest radiographic manifestations of scrub typhus.

    Science.gov (United States)

    Abhilash, Kpp; Mannam, P R; Rajendran, K; John, R A; Ramasami, P

    2016-01-01

    Respiratory system involvement in scrub typhus is seen in 20-72% of patients. In endemic areas, good understanding and familiarity with the various radiologic findings of scrub typhus are essential in identifying pulmonary complications. Patients admitted to a tertiary care center with scrub typhus between October 2012 and September 2013 and had a chest X ray done were included in the analysis. Details and radiographic findings were noted and factors associated with abnormal X-rays were analyzed. The study cohort contained 398 patients. Common presenting complaints included fever (100%), generalized myalgia (83%), headache (65%), dyspnea (54%), cough (24.3%), and altered sensorium (14%). Almost half of the patients (49.4%) had normal chest radiographs. Common radiological pulmonary abnormalities included pleural effusion (14.6%), acute respiratory distress syndrome (14%), airspace opacity (10.5%), reticulonodular opacities (10.3%), peribronchial thickening (5.8%), and pulmonary edema (2%). Cardiomegaly was noted in 3.5% of patients. Breathlessness, presence of an eschar, platelet counts of 2 mg/dL had the highest odds of having an abnormal chest radiograph. Patients with an abnormal chest X-ray had a higher requirement of noninvasive ventilation (odds ratio [OR]: 13.98; 95% confidence interval CI: 5.89-33.16), invasive ventilation (OR: 18.07; 95% CI: 6.42-50.88), inotropes (OR: 8.76; 95% CI: 4.35-17.62), higher involvement of other organ systems, longer duration of hospital stay (3.18 ± 3 vs. 7.27 ± 5.58 days; Pscrub typhus have abnormal chest radiographs. Chest radiography should be included as part of basic evaluation at presentation in patients with scrub typhus, especially in those with breathlessness, eschar, jaundice, and severe thrombocytopenia.

  19. Radiograph identifying means

    International Nuclear Information System (INIS)

    Sheldon, A.D.

    1983-01-01

    A flexible character-indentable plastics embossing tape is backed by and bonded to a lead strip, not more than 0.025 inches thick, to form a tape suitable for identifying radiographs. The lead strip is itself backed by a relatively thin and flimsy plastics or fabric strip which, when removed, allows the lead plastic tape to be pressure-bonded to the surface to be radiographed. A conventional tape-embossing gun is used to indent the desired characters in succession into the lead-backed tape, without necessarily severing the lead; and then the backing strip is peeled away to expose the layer of adhesive which pressure-bonds the indented tape to the object to be radiographed. X-rays incident on the embossed tape will cause the raised characters to show up dark on the subsequently-developed film, whilst the raised side areas will show up white. Each character will thus stand out on the developed film. (author)

  20. Meta-analysis of Clinical and Radiographic Outcomes After Arthroscopic Single-Row Versus Double-Row Rotator Cuff Repair.

    Science.gov (United States)

    Perser, Karen; Godfrey, David; Bisson, Leslie

    2011-05-01

    Double-row rotator cuff repair methods have improved biomechanical performance when compared with single-row repairs. To review clinical outcomes of single-row versus double-row rotator cuff repair with the hypothesis that double-row rotator cuff repair will result in better clinical and radiographic outcomes. Published literature from January 1980 to April 2010. Key terms included rotator cuff, prospective studies, outcomes, and suture techniques. The literature was systematically searched, and 5 level I and II studies were found comparing clinical outcomes of single-row and double-row rotator cuff repair. Coleman methodology scores were calculated for each article. Meta-analysis was performed, with treatment effect between single row and double row for clinical outcomes and with odds ratios for radiographic results. The sample size necessary to detect a given difference in clinical outcome between the 2 methods was calculated. Three level I studies had Coleman scores of 80, 74, and 81, and two level II studies had scores of 78 and 73. There were 156 patients with single-row repairs and 147 patients with double-row repairs, both with an average follow-up of 23 months (range, 12-40 months). Double-row repairs resulted in a greater treatment effect for each validated outcome measure in 4 studies, but the differences were not clinically or statistically significant (range, 0.4-2.2 points; 95% confidence interval, -0.19, 4.68 points). Double-row repairs had better radiographic results, but the differences were also not statistically significant (P = 0.13). Two studies had adequate power to detect a 10-point difference between repair methods using the Constant score, and 1 study had power to detect a 5-point difference using the UCLA (University of California, Los Angeles) score. Double-row rotator cuff repair does not show a statistically significant improvement in clinical outcome or radiographic healing with short-term follow-up.

  1. Radiographic Evaluation of Ankle Joint Stability After Calcaneofibular Ligament Elevation During Open Reduction and Internal Fixation of Calcaneus Fracture.

    Science.gov (United States)

    Wang, Chien-Shun; Tzeng, Yun-Hsuan; Lin, Chun-Cheng; Huang, Ching-Kuei; Chang, Ming-Chau; Chiang, Chao-Ching

    2016-09-01

    The aim of this prospective study was to evaluate the influence of sectioning the calcaneofibular ligament (CFL) during an extensile lateral approach during open reduction and internal fixation (ORIF) of calcaneal fractures on ankle joint stability. Forty-two patients with calcaneal fractures that received ORIF were included. Talar tilt stress and anterior drawer radiographs were performed on the operative and contralateral ankles 6 months postoperatively. The average degree of talar tilt on stress radiographs was 3.4 degrees (range, 0-12 degrees) on the operative side and 3.2 degrees (range, 0-14 degrees) on the contralateral side. The mean anterior drawer on stress radiographs of the CFL incised ankle was 6.1 mm (range, 2.4-11.8 mm) and on the contralateral ankle was 5.7 mm (range, 2.6-8.6 mm). There was no statistically significant difference of talar tilt and anterior drawer between the CFL incised side and the contralateral side (P = .658 and .302, respectively). The results suggest that sectioning of the CFL without any repair during ORIF of a calcaneal fracture does not have a negative effect on stability of the ankle. Repair of the CFL is, thus, probably not necessary following extended lateral approach for ORIF of calcaneal fractures. Level II, comparative study. © The Author(s) 2016.

  2. Student radiographers' attitudes toward the older patient – An intervention study

    International Nuclear Information System (INIS)

    Booth, L.; Kada, S.

    2015-01-01

    Purpose: To design, implement and evaluate the effect of an educational intervention on Norwegian student (diagnostic) radiographers' attitudes towards older people. Design: This study is part of a wider longitudinal study that will evaluate student radiographer attitudes towards the older patient as they progress through their training. In this phase an educational intervention, aimed at improving student radiographer attitudes towards the older person, was designed and implemented. What is reported here are the findings of a pre-test, post-test design that used the Kogan's attitudes towards older people scale to determine whether this intervention had any effect of student radiographer attitudes towards older people. Results: Overall students reported significantly more positive attitudes towards older people after intervention (p = 0.01). However, analysis of responses to individual questions reveals that this difference was not significant in all cases. Conclusion: The results of the present study suggest that an educational intervention can have a significant impact on student radiographer's attitudes towards older people. Whether this positive attitude remains throughout training, forms part of the wider basis for this study. - Highlights: • We designed an education intervention to improve Norwegian student radiographer attitudes towards older people. • Pre-intervention we found that these student radiographers generally had positive attitudes towards older people. • Post intervention the student radiographer's attitudes towards older people were significantly improved

  3. Relationship between Investigative Biomarkers and Radiographic Grading in Patients with Knee Osteoarthritis

    Science.gov (United States)

    Anitua, Eduardo; Sánchez, Mikel; de la Fuente, Maria; Azofra, Juan; Zalduendo, Mar; Aguirre, Jose J.; Andía, Isabel

    2009-01-01

    Objective. To examine new investigative biomarkers and their relevance for radiographic severity in knee osteoarthritis. Methods. The group comprised 63 patients with 73 knees examined. Patients were divided according to radiographic severity to allow for comparison of biomarker levels. Hyaluronic acid (HA), matrix metalloproteases (MMP-1, MMP-3 and MMP-13), tissue inhibitors of metalloproteases (TIMP-1 and TIMP-2), platelet-derived growth factor (PDGF-AB), transformed growth factor (TGF-β), vascular endothelial growth factor (VEGF), hepatocyte growth factor (HGF) and insulin-like growth factor (IGF-I) were measured on synovial fluid and in plasma releasate at a single time point. Principal component analysis (PCA) followed by analysis of covariance were applied to evaluate data. Results. Four different groups of biomarker were identified in plasma releasates. The first (platelet number, PDGF-AB and TGF-β) and second groups (HA and IGF-I) were related to radiographic severity, P = .005 and P = .022, respectively. The third (MMP-1 and TIMP-2) and fourth groups (MMP-3 and TIMP-1) represented the catabolic balance, but were not associated to radiographic grading. Three different clusters of biomarkers were found in synovial fluid but did not show any significant association to radiographic grading. Conclusions. New imaging approaches to assess structural deterioration and correlation with biomarker levels are warranted to advance in OA research. PMID:20130801

  4. Relationship between Investigative Biomarkers and Radiographic Grading in Patients with Knee Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Eduardo Anitua

    2009-01-01

    Full Text Available Objective. To examine new investigative biomarkers and their relevance for radiographic severity in knee osteoarthritis. Methods. The group comprised 63 patients with 73 knees examined. Patients were divided according to radiographic severity to allow for comparison of biomarker levels. Hyaluronic acid (HA, matrix metalloproteases (MMP-1, MMP-3 and MMP-13, tissue inhibitors of metalloproteases (TIMP-1 and TIMP-2, platelet-derived growth factor (PDGF-AB, transformed growth factor (TGF-β, vascular endothelial growth factor (VEGF, hepatocyte growth factor (HGF and insulin-like growth factor (IGF-I were measured on synovial fluid and in plasma releasate at a single time point. Principal component analysis (PCA followed by analysis of covariance were applied to evaluate data. Results. Four different groups of biomarker were identified in plasma releasates. The first (platelet number, PDGF-AB and TGF-β and second groups (HA and IGF-I were related to radiographic severity, P=.005 and P=.022, respectively. The third (MMP-1 and TIMP-2 and fourth groups (MMP-3 and TIMP-1 represented the catabolic balance, but were not associated to radiographic grading. Three different clusters of biomarkers were found in synovial fluid but did not show any significant association to radiographic grading. Conclusions. New imaging approaches to assess structural deterioration and correlation with biomarker levels are warranted to advance in OA research.

  5. Presence of bias in radiographer plain film reading performance studies

    International Nuclear Information System (INIS)

    Brealey, S.; Scally, A.J.; Thomas, N.B.

    2002-01-01

    Purpose To raise awareness of the frequency of bias that can affect the quality of radiographer plain film reading performance studies. Methods Studies that assessed radiographer(s) plain film reading performance were located by searching electronic databases and grey literature, hand-searching journals, personal communication and scanning reference lists. Thirty studies were judged eligible from all data sources. Results A one-way analysis of variance (ANOVA) demonstrates no statistically significant difference (P=0.25) in the mean proportion of biases present from diagnostic accuracy (0.37), performance (0.42) and outcome (0.44) study designs. Pearson's correlation coefficient showed no statistically significant linear association between the proportion of biases present for the three different study designs and the year that the study was performed. The frequency of biases in film and observer selection and application of the reference standard was quite low. In contrast, many biases were present concerning independence of film reporting and comparison of reports for concordance. Conclusions The findings indicate variation in the presence of bias in radiographer plain film reading performance studies. The careful consideration of bias is an essential component of study quality and hence the validity of the evidence-base used to underpin radiographic reporting policy

  6. Effectiveness Of Plain Shoulder Radiograph In Detecting Degenerate Rotator Cuff Tears.

    Science.gov (United States)

    Hussain, Adnan; Muzzammil, Muhammad; Butt, Faisal; Valsamis, Epaminondas Markos; Dwyer, Amitabh J

    2018-01-01

    Studies have demonstrated radiographic findings of sclerosis and cortical irregularity at the greater tuberosity can suggest a rotator cuff tear. Plain radiographs are the most easily attainable first-line investigations in evaluating shoulder injuries. This study determines the effectiveness in predicting degenerate rotator cuff tears by detecting radiographic changes on shoulder x-rays. Retrospective cross-sectional study with a consecutive series of patients conducted in Hinchingbrooke Hospital, Huntingdon, United Kingdom from January 2015 to June 2017. Anteroposterior shoulder radiographs of 150 symptomatic patients who underwent shoulder arthroscopy were independently analysed by surgeons who were blinded from the arthroscopic results. Patients aged fewer than 30 and over 70 years were excluded. Patients with advanced osteoarthritis and cuff tear arthropathy evident on x-rays were also excluded. Sixty-five patients included in the study had rotator cuff tears on arthroscopy. Radiographic changes were correlated with arthroscopic findings to determine this test's ability to predict degenerate rotator cuff tears. When both cortical irregularity and sclerosis were present on the plain radiograph, these signs had a sensitivity of 78.8% [95% CI 65.7, 87.8%] and specificity 77.4% [95% CI 67.2, 85.0%] with a positive predictive value of 68.3%, using contingency table analysis. The presence of cortical irregularity was found to be a better predictor of a tear as compared to sclerosis. This study concludes that plain radiograph are good modality for initial evaluation of rotator cuff tears and detecting when both cortical irregularity and sclerosis. Consideration of these radiographic findings serves as a useful adjunct in diagnostic workup and can guide subsequent investigations and treatment when evaluating rotator cuff tears of the shoulder.

  7. Correction of radiographic measurements of acetabular cup wear for variations in pelvis orientation.

    Science.gov (United States)

    Derbyshire, Brian

    2018-03-01

    Radiographic measurement of two-dimensional acetabular cup wear is usually carried out on a series of follow-up radiographs of the patient's pelvis. Since the orientation of the pelvis might not be consistent at every X-ray examination, the resulting change in view of the wear plane introduces error into the linear wear measurement. This effect is amplified on some designs of cup in which the centre of the socket is several millimetres below the centre of the cup or circular wire marker. This study describes the formulation of a mathematical method to correct radiographic wear measurements for changes in pelvis orientation. A mathematical simulation of changes in cup orientation and wear vectors caused by pelvic tilt was used to confirm that the formulae corrected the wear exactly if the radiographic plane of the reference radiograph was parallel to the true plane of wear. An error analysis showed that even when the true wear plane was not parallel to the reference radiographic plane, the formulae could still provide a useful correction. A published correction formula was found to be ineffective.

  8. Legalities of the radiograph

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    The radiograph itself plays a major role in medical malpractice cases. Also, many questions arise concerning the rights to and storage of x-ray films. These issues are addressed in this chapter. To keep the terminology simple, the word radiograph represents all imaging documentation on hard copy film (x-rays, nuclear medicine, computer-assisted studies, ultrasound, and magnetic resonance imaging)

  9. Practical stress analysis in engineering design

    CERN Document Server

    Huston, Ronald

    2008-01-01

    Presents the application of engineering design and analysis based on the approach of understanding the physical characteristics of a given problem and then modeling the important aspects of the physical system. This book covers such topics as contact stress analysis, singularity functions, gear stresses, fasteners, shafts, and shaft stresses.

  10. Consultant breast radiographers: Where are we now?

    International Nuclear Information System (INIS)

    Rees, Zebby

    2014-01-01

    Introduction: The aim of this study is to: • Evaluate the current role of the consultant breast radiographer. • Compare current practice with the four key components for consultant practice. • Gauge the support of radiologist colleagues. • Determine the other professional commitments involved with the role. This study could be the precursor for a macro study of all consultant radiographer practice in other specialities. Methodology: Methodology used was a comparative ethnographic study. Questionnaires to the 24 consultant breast radiographers currently in post, and consultant breast radiologists, who work with them, were conducted. Data collection was a qualitative thematic approach. Conclusion: Consultant breast radiographers provide high quality care to patients through excellent clinical practice, leadership and good communication. However, this study shows hospital Trusts emphasis for non medical consultants is for clinical practice first. Some radiologists are still a barrier to progression for consultant breast radiographers, and radiologists have a big influence in recruitment decisions. Consultant breast radiographer posts are well established, their numbers are increasing through recognition of the role and of their abilities and performance. Consultant breast radiographers state that becoming a consultant is the major achievement of their career, proving the Society of Radiographers' vision of the four-tier career structure has been well received by the radiography profession

  11. Importance of radiographic monitoring of endoscopic sphincterotomy

    International Nuclear Information System (INIS)

    Greenberg, H.M.; Goldberg, H.I.; Shapiro, H.A.

    1981-01-01

    The radiographic features of endoscopic sphincterotomies performed in 44 patients were evaluated. Radiographic landmarks aided in proper sphincterotome placement and also disclosed conditions and anatomic variations that made catheter placement difficult. Fluoroscopic and radiographic monitoring not only assisted the performance of endoscopic sphincterotomy, but also confirmed successful results and revealed reasons for failure. Radiographic changes in the biliary tract after sphincterotomy, as well as potential complications of sphincterotomy, are discussed and illustrated

  12. Correlation of bone quality in radiographic images with clinical bone quality classification

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Woo; Huh, Kyung Hoe; Kim, Jeong Hwa; Yi, Won Jin; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul [Seoul National University, Seoul (Korea, Republic of); Park, Kwan Soo [Inje University, Seoul (Korea, Republic of)

    2006-03-15

    To investigate the validity of digital image processing on panoramic radiographs in estimating bone quality before endosseous dental implant installation by correlating bone quality in radiographic images with clinical bone quality classification. An experienced surgeon assessed and classified bone quality for implant sites with tactile sensation at the time of implant placement. Including fractal dimension eighteen morphologic features of trabecular pattern were examined in each anatomical sites on panoramic radiographs. Finally bone quality of 67 implant sites were evaluated in 42 patients. Pearson correlation analysis showed that three morphologic parameters had weak linear negative correlation with clinical bone quality classification showing correlation coefficients of -0.276, -0.280, and -0.289, respectively (p<0.05). And other three morphologic parameters had obvious linear negative correlation with clinical bone quality classification showing correlation coefficients of -0.346, -0.488, and -0.343 respectively (p<0.05). Fractal dimension also had a linear correlating with clinical bone quality classification with correlation coefficients -0.506 significantly (P<0.05). This study suggests that fractal and morphometric analysis using digital panoramic radiographs can be used to evaluate bone quality for implant recipient sites.

  13. Radiation protection - radiographer's role and responsibilities

    International Nuclear Information System (INIS)

    Popli, P.K.

    2002-01-01

    Ever since discovery of x-rays, radiographers has been the prime user of radiation. With the passage of time, the harmful effects of radiation were detected. Some of radiographers, radiologists and public were affected by radiation, but today with enough knowledge of radiation, the prime responsibility of radiation protection lies with the radiographers only. The radiologist and physicist are also associated with radiation protection to some extent

  14. Intra-observer reproducibility and interobserver reliability of the radiographic parameters in the Spinal Deformity Study Group's AIS Radiographic Measurement Manual.

    Science.gov (United States)

    Dang, Natasha Radhika; Moreau, Marc J; Hill, Douglas L; Mahood, James K; Raso, James

    2005-05-01

    Retrospective cross-sectional assessment of the reproducibility and reliability of radiographic parameters. To measure the intra-examiner and interexaminer reproducibility and reliability of salient radiographic features. The management and treatment of adolescent idiopathic scoliosis (AIS) depends on accurate and reproducible radiographic measurements of the deformity. Ten sets of radiographs were randomly selected from a sample of patients with AIS, with initial curves between 20 degrees and 45 degrees. Fourteen measures of the deformity were measured from posteroanterior and lateral radiographs by 2 examiners, and were repeated 5 times at intervals of 3-5 days. Intra-examiner and interexaminer differences were examined. The parameters include measures of curve size, spinal imbalance, sagittal kyphosis and alignment, maximum apical vertebral rotation, T1 tilt, spondylolysis/spondylolisthesis, and skeletal age. Intra-examiner reproducibility was generally excellent for parameters measured from the posteroanterior radiographs but only fair to good for parameters from the lateral radiographs, in which some landmarks were not clearly visible. Of the 13 parameters observed, 7 had excellent interobserver reliability. The measurements from the lateral radiograph were less reproducible and reliable and, thus, may not add value to the assessment of AIS. Taking additional measures encourages a systematic and comprehensive assessment of spinal radiographs.

  15. Preoperative Radiographic and CT Findings Predicting Syndesmotic Injuries in Supination-External Rotation-Type Ankle Fractures.

    Science.gov (United States)

    Choi, Young; Kwon, Soon-Sun; Chung, Chin Youb; Park, Moon Seok; Lee, Seung Yeol; Lee, Kyoung Min

    2014-07-16

    The Lauge-Hansen classification system does not provide sufficient data related to syndesmotic injuries in supination-external rotation (SER)-type ankle fractures. The aim of the present study was to investigate factors helpful for the preoperative detection of syndesmotic injuries in SER-type ankle fractures using radiographs and computed tomography (CT). A cohort of 191 consecutive patients (104 male and eighty-seven female patients with a mean age [and standard deviation] of 50.7 ± 16.4 years) with SER-type ankle fractures who had undergone operative treatment were included. Preoperative ankle radiographs and CT imaging scans were made for all patients, and clinical data, including age, sex, and mechanism of injury (high or low-energy trauma), were collected. Patients were divided into two groups: the stable syndesmotic group and the unstable syndesmotic group, with a positive intraoperative lateral stress test leading to syndesmotic screw fixation. Fracture height, fracture length, medial joint space, extent of fracture, and bone attenuation were measured on radiographs and CT images and were compared between the groups. Binary logistic regression analysis was performed to identify the factors that significantly contributed to unstable syndesmotic injuries. Receiver operating characteristic curves were calculated, and cutoff values were suggested to predict unstable syndesmotic injuries on preoperative imaging measurements. Of the 191 patents with a SER-type ankle fracture, thirty-eight (19.9%) had a concurrent unstable syndesmotic injury. Age, sex, mechanism of injury, fracture height, medial joint space, and bone attenuation were significantly different between the two groups. In the binary logistic analysis, fracture height, medial joint space, and bone attenuation were found to be significant factors contributing to unstable syndesmotic injuries. The cutoff values for predicting unstable syndesmotic injuries were a fracture height of >3 mm and a medial

  16. Persistent axial neck pain after cervical disc arthroplasty: a radiographic analysis.

    Science.gov (United States)

    Wagner, Scott C; Formby, Peter M; Kang, Daniel G; Van Blarcum, Gregory S; Cody, John P; Tracey, Robert W; Lehman, Ronald A

    2016-07-01

    There is very little literature examining optimal radiographic parameters for placement of cervical disc arthroplasty (CDA), nor is there substantial evidence evaluating the relationship between persistent postoperative neck pain and radiographic outcomes. We set out to perform a single-center evaluation of the radiographic outcomes, including associated complications, of CDA. This is a retrospective review. Two hundred eighty-five consecutive patients undergoing CDA were included in the review. The outcome measures were radiological parameters (preoperative facet arthrosis, disc height, CDA placement in sagittal and coronal planes, heterotopic ossification [HO] formation, etc.) and patient outcomes (persistent pain, recurrent pain, new-onset pain, etc.). We performed a retrospective review of all patients from a single military tertiary medical center from August 2008 to August 2012 undergoing CDA. Preoperative, immediate postoperative, and final follow-up films were evaluated. The clinical outcomes and complications associated with the procedure were also examined. The average radiographic follow-up was 13.5 months and the rate of persistent axial neck pain was 17.2%. For patients with persistent neck pain, the rate of HO formation per level studied was 22.6%, whereas the rate was significantly lower for patients without neck pain (11.7%, p=.03). There was no significant association between the severity of HO and the presence of neck pain. Patients with a preoperative diagnosis of cervicalgia, compared to those without cervicalgia, were significantly more likely to experience continued neck pain postoperatively (28.6% vs. 13.1%, p=.01). There were no differences in preoperative facet arthrosis, pre- or postoperative disc height, segmental range of motion, or placement of the device relative to the posterior edge of the vertebral body.However, patients with implants more centered between the uncovertebral joints were more likely to experience posterior neck pain

  17. Radiographic estimation in seropositive and seronegative rheumatoid arthritis.

    Science.gov (United States)

    Sahatçiu-Meka, Vjollca; Rexhepi, Sylejman; Manxhuka-Kërliu, Suzana; Rexhepi, Mjellma

    2011-08-01

    Long since it have been suggested that a subpopulation of patients with rheumatoid arthritis, diagnosed with negative rheumatoid factor tests, represents a clinical entity quite distinct from that of seropositive rheumatoid arthritis (RA). Our aim was to establish a scientific comparative analysis between seronegative and seropositive rheumatoid arthritis, regarding some radiological and clinical parameters, applied for the first time on patients from Kosovo. Two hundred fifty patients with rheumatoid arthritis according to the American College of Rheumatology criteria were retrospectively studied by analysis the radiographic damage and clinical parameters of the disease, using a data base. All examinees were between 25-60 years of age (Xb=49.96, SD=10.37) with disease duration between 1-27 years (Xb = 6.41, SD=6.47). All patients underwent a standardised evaluation radiographs. Baseline standardised poster anterior radiographs of hands and feet and radiographs of other joints, depending on indications, were assessed. Erythrocyte sedimentation rate values correlated with the radiological damages and statistical difference was found for seronegative subset (r=0.24, p<0.01). Longer duration of the disease resulted in the increase of radiological changes in both subsets (r=0.66, p<0.01) seronegative, (r=0.49, p<0.01) seropositive. Anatomic changes of IInd and IIIrd level were nearly equally distributed in both subsets, 76 (60.8%) seronegative, 75 (60%) seropositive. Radiological damages are nearly equal in both subsets, elevate in relation to the duration of the disease and correlate with ESR values. Regarding the sero-status, differences within sex, with some exceptions, are not relevant. Although there are some definite quantitative and qualitative differences regarding sero-status, obviously there is a great deal of overlap between the two groups.

  18. Radiographic estimation in seropositive and seronegative rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Vjollca Sahatçiu-Meka

    2011-08-01

    Full Text Available Long since it have been suggested that a subpopulation of patients with rheumatoid arthritis, diagnosed with negative rheumatoid factor tests, represents a clinical entity quite distinct from that of seropositive rheumatoid arthritis (RA. Our aim was to establish a scientific comparative analysis between seronegative and seropositive rheumatoid arthritis, regarding some radiological and clinical parameters, applied for the first time on patients from Kosovo. Two hundred fifty patients with rheumatoid arthritis according to the American College of Rheumatology criteria were retrospectively studied by analysis the radiographic damage and clinical parameters of the disease, using a data base. All examinees were between 25-60 years of age (Xb=49.96, SD=10.37 with disease duration between 1-27 years (Xb = 6.41, SD=6.47. All patients underwent a standardised evaluation radiographs. Baseline standardised poster anterior radiographs of hands and feet and radiographs of other joints, depending on indications, were assessed. Erythrocyte sedimentation rate values correlated with the radiological damages and statistical difference was found for seronegative subset (r=0.24, p<0.01. Longer duration of the disease resulted in the increase of radiological changes in both subsets (r=0.66, p<0.01 seronegative, (r=0.49, p<0.01 seropositive. Anatomic changes of IInd and IIIrd level were nearly equally distributed in both subsets, 76 (60.8% seronegative, 75 (60% seropositive. Radiological damages are nearly equal in both subsets, elevate in relation to the duration of the disease and correlate with ESR values. Regarding the sero-status, differences within sex, with some exceptions, are not relevant. Although there are some definite quantitative and qualitative differences regarding sero-status, obviously there is a great deal of overlap between the two groups.

  19. The Radiographer's multidisciplinary team role in theatre scenarios

    International Nuclear Information System (INIS)

    Williams, H.; Widdowfield, M.; Cosson, P.

    2015-01-01

    Background: Radiographers work in multidisciplinary teams (MDTs) to image intra-operatively using ionising radiation. The radiographer is responsible according to IR(ME)ER (2000) and IRR(99) regulations for advocating patient and theatre personnel safety. A comprehensive literature search revealed limited studies analysing the radiographer's experiences of utilising power to influence MDTs. Therefore the aim of the study was to explore the power relationships within different MDT scenarios. Method: A qualitative approach was adopted consisting of interviews exploring radiographers' experiences as 1) established Cardiology team members and 2) transient members of Orthopaedic teams. French and Raven's power bases were used as an a priori framework. Ethical approval was obtained prior to commencement. Sampling was purposive, following gatekeeper permission, and subsequent participation was voluntary. Thematic content analysis was undertaken following data collection. Findings and discussion: Perpetration of Legitimate Power was more frequently attempted in transient teams. However, there were more successful descriptions in established teams. Expert Power was reciprocated successfully in established teams but was context dependent in transient teams. Referent power was well used by participants, although the transient nature of teams did affect this. Job satisfaction was expressed by both groups, although evidence presented was more comprehensive in established teams. Conclusion: The social bases of power at play within two MDTs have been examined. It is unclear to what extent the team specialism has a role in the differences identified. Radiographers working in established teams may have greater job satisfaction and perpetrate power bases more effectively than radiographers serving in transient teams. - Highlights: • This is a qualitative study using a phenomenological approach. • The social bases of power are adopted as an a priori theoretical

  20. Radiographic, high detail radiographic, microangiographic and histological findings of the distal portion of the tarsus in weanling young and adult horses

    International Nuclear Information System (INIS)

    Laverty, S.; Stover, S.M.; Bélanger, D.; O'Brien, T.R.; Pool, R.R.; Pascoe, J.R.; Taylor, K.; Harrington, T.

    1991-01-01

    Clinical radiographic (LM and D35L-P1MO reviews), high detail radiographic, microangiographic and histological findings of distal portion of the tarsus of 16 horses (five weanling, four young and six adult), without known clinical histories, were evaluated to determine the sensitivity of clinical radiographs for the detection of abnormalities in the distal tarsus and the prevalence of abnormalities in this population. Clinical radiographic and high detail radiographic abnormalities were observed in at least 30 per cent of the tarsi examined. Statistical agreement between observations from clinical radiographs and corresponding post mortem high detail radiographs was not good for subchondral bone plate irregularities and joint margin changes. Three patterns of sclerosis of the medullary spongiosa were visualized on high detail radiographs; thickening of the subchondral bone plate was seen commonly in the weaning group,, whereas arching and bridging patterns were more prevalent in the young and adult groups. Bone production on the dorsal cortex of the central and third tarsal bones did not increase with age. Abnormalities in vascular perfusion and articular cartilage histology were observed in association with subchondral bone plate irregularities and focal regions of osteopenia observed on high detail radiographs

  1. Long-term outcomes of dental implants placed in elderly patients: a retrospective clinical and radiographic analysis.

    Science.gov (United States)

    Park, Jung-Chul; Baek, Won-Sun; Choi, Seong-Ho; Cho, Kyoo-Sung; Jung, Ui-Won

    2017-02-01

    The aim of this retrospective study was to determine the clinical and the radiographic outcomes of dental implants placed in elderly people older than 65 years. In total, 902 implants in 346 patients (age: 65-89 years) were followed up for 2-17 years following the implant surgery. The survival rate of these implants was recorded and analyzed. Changes in marginal bone levels were also analyzed in serial radiographs, and Cox regression analysis for implant loss was performed. The survival rates were 95.39% and 99.98% in the implant- and patient-based analyses, respectively (involving a total of 29 implant failures), and the marginal bone loss at the implants was 0.17 ± 0.71 mm (mean ± SD). The number of failures was greatest in patients aged 65-69 years. The Cox regression with shared frailty analysis showed that implant loss was significantly greater in those aged 65-69 years than in those aged 70-74 years (P implant systems. Within the limitations of this retrospective study, it was concluded that implant therapy can be successfully provided to elderly patients and that age alone does not seem to affect the implant survival rate. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Computer stress study of bone with computed tomography

    International Nuclear Information System (INIS)

    Linden, M.J.; Marom, S.A.; Linden, C.N.

    1986-01-01

    A computer processing tool has been developed which, together with a finite element program, determines the stress-deformation pattern in a long bone, utilizing Computed Tomography (CT) data files for the geometry and radiographic density information. The geometry, together with mechanical properties and boundary conditions: loads and displacements, comprise the input of the Finite element (FE) computer program. The output of the program is the stresses and deformations in the bone. The processor is capable of developing an accurate three-dimensional finite element model from a scanned human long bone due to the CT high pixel resolution and the local mechanical properties determined from the radiographic densities of the scanned bone. The processor, together with the finite element program, serves first as an analysis tool towards improved understanding of bone function and remodelling. In this first stage, actual long bones may be scanned and analyzed under applied loads and displacements, determined from existing gait analyses. The stress-deformation patterns thus obtained may be used for studying the biomechanical behavior of particular long bones such as bones with implants and with osteoporosis. As a second stage, this processor may serve as a diagnostic tool for analyzing the biomechanical response of a specific patient's long long bone under applied loading by utilizing a CT data file of the specific bone as an input to the processor with the FE program

  3. Simulated radiographic bone and joint modeling from 3D ankle MRI: feasibility and comparison with radiographs and 2D MRI

    Energy Technology Data Exchange (ETDEWEB)

    Nordeck, Shaun M. [University of Texas Southwestern Medical College, Dallas, TX (United States); University of Texas Southwestern Medical Center, Musculoskeletal Radiology, Dallas, TX (United States); Koerper, Conrad E.; Adler, Aaron [University of Texas Southwestern Medical College, Dallas, TX (United States); Malhotra, Vidur; Xi, Yin [University of Texas Southwestern Medical Center, Musculoskeletal Radiology, Dallas, TX (United States); Liu, George T. [University of Texas Southwestern Medical Center, Orthopaedic Surgery, Dallas, TX (United States); Chhabra, Avneesh [University of Texas Southwestern Medical Center, Musculoskeletal Radiology, Dallas, TX (United States); University of Texas Southwestern Medical Center, Orthopaedic Surgery, Dallas, TX (United States)

    2017-05-15

    The purpose of this work is to simulate radiographs from isotropic 3D MRI data, compare relationship of angle and joint space measurements on simulated radiographs with corresponding 2D MRIs and real radiographs (XR), and compare measurement times among the three modalities. Twenty-four consecutive ankles were included, eight males and 16 females, with a mean age of 46 years. Segmented joint models simulating radiographs were created from 3D MRI data sets. Three readers independently performed blinded angle and joint space measurements on the models, corresponding 2D MRIs, and XRs at two time points. Linear mixed models and the intraclass correlation coefficient (ICC) was ascertained, with p values less than 0.05 considered significant. Simulated radiograph models were successfully created in all cases. Good agreement (ICC > 0.65) was noted among all readers across all modalities and among most measurements. Absolute measurement values differed between modalities. Measurement time was significantly greater (p < 0.05) on 2D versus simulated radiographs for most measurements and on XR versus simulated radiographs (p < 0.05) for nearly half the measurements. Simulated radiographs can be successfully generated from 3D MRI data; however, measurements differ. Good inter-reader and moderate-to-good intra-reader reliability was observed and measurements obtained on simulated radiograph models took significantly less time compared to measurements with 2D and generally less time than XR. (orig.)

  4. Radiation protection education and training of radiographers

    International Nuclear Information System (INIS)

    Elsakkers, P.

    1995-01-01

    The International Society of Radiographers and Radiological Technicians (ISRRT) is an international non-governmental organisation in official relationship with the World Health Organization. Over 50 countries are members of the ISRRT. The ISRRT encourages and facilitates communication between radiographers throughout the world. The ISRRT has produced several documents, e.g. ''The Role of the Radiographer in Europe''. The ISRRT has also done research and developed initiatives to analyse the quality of training of radiographers in the different member states of the EC. Research was done in the member states to analyse the efforts in the field of quality control. An extended study was performed on the current level of education in radiation protection in the European member states. The ICRP recommends in its publications the need of good training and continuing education for all radiographers. An important part of the basic training of radiographers should focus on the performance of radiation protection and quality control tests. Good daily practice can decrease patient dose in many ways. (Author)

  5. Concept Analysis: Alzheimer's Caregiver Stress.

    Science.gov (United States)

    Llanque, Sarah; Savage, Lynette; Rosenburg, Neal; Caserta, Michael

    2016-01-01

    The aim of this article was to analyze the concept of caregiver stress in the context of caring for a person with Alzheimer's disease and related dementias. Currently, there are more than 15 million unpaid caregivers for persons suffering from Alzheimer's disease and related dementias. This unpaid care can be stressful for caregivers due to the chronic nature of the disease process, as well as other factors. The paper incorporates the modified method of Wilson's concept analysis procedure to analyze the concept of caregiver stress. A review of the literature was undertaken using the Cumulative Index to Nursing and Allied Health Literature, Google Scholar, and PubMed. A theoretical definition of caregiver stress is provided, and the defining attributes, related concepts, antecedents, and consequences of caregiver stress are proposed, and case studies are presented. The analysis demonstrates that caregiver stress is the unequal exchange of assistance among people who stand in close relationship to one another, which results in emotional and physical stress on the caregiver. Implications for future nursing research and practice conclude the paper. © 2014 Wiley Periodicals, Inc.

  6. The radiographic investigation of two Egyptian mummies.

    Science.gov (United States)

    Fodor, J; Malott, J C; King, A Y

    1983-01-01

    Radiography is a well-recognized method of nondestructive analysis of art objects and ancient relics. The methods and techniques used in the examination of two ancient Egyptian mummies are presented here. Additionally, the use of radiographic findings to help substantiate alleged historical information and to establish sex, age, and pathology of each specimen is discussed.

  7. Joining U.S. NRC international round robin for weld residual stress analysis. Stress analysis and validation in PWSCC mitigation program

    International Nuclear Information System (INIS)

    Maekawa, Akira; Serizawa, Hisashi; Murakawa, Hidekazu

    2012-01-01

    It is necessary to establish properly reliable weld residual stress analysis methods for accurate crack initiation and growth assessment of primary water stress corrosion cracking (PWSCC), which may occur in nickel-based dissimilar metal welds in pressurized water reactors. The U.S. Nuclear Regulatory Commission conducted an international round robin for weld residual stress analysis to improve stress analysis methods and to examine the uncertainties involved in the calculated stress values. In this paper, the results from the authors' participation in the round robin were reported. In the round robin, the weld residual stress in a nickel-based dissimilar metal weld of a pressurizer surge nozzle mock-up was computed under various analysis conditions. Based on these residual stress analysis results, a welding simulation code currently being developed that uses the iterative substructure method was validated and affecting factors on the analysis results were identified. (author)

  8. Predicting lower third molar eruption on panoramic radiographs after cephalometric comparison of profile and panoramic radiographs

    DEFF Research Database (Denmark)

    Begtrup, Anders; Grønastøð, Halldis Á; Christensen, Ib Jarle

    2012-01-01

    and to find a simple and reliable method for predicting the eruption of the mandibular third molar by measurements on panoramic radiographs. The material consisted of profile and panoramic radiographs, taken before orthodontic treatment, of 30 males and 23 females (median age 22, range 18-48 years......Previous studies have suggested methods for predicting third molar tooth eruption radiographically. Still, this prediction is associated with uncertainty. The aim of the present study was to elucidate the association between cephalometric measurements on profile and panoramic radiographs...... the length from the ramus to the incisors (olr-id) showed a statistically significant correlation. By combining this length with the mesiodistal width of the lower second molar, the prediction of eruption of the lower third molar was strengthened. A new formula for calculating the probability of eruption...

  9. Ergonomic strategies to improve radiographers' posture during mammography activities.

    Science.gov (United States)

    Cernean, Nicolai; Serranheira, Florentino; Gonçalves, Pedro; Sá Dos Reis, Cláudia

    2017-08-01

    To identify alternatives for radiographers' postures while performing mammography that can contribute to reduce the risk of work-related musculoskeletal disorders (WRMSDs). Radiographers' postures to positioning craniocaudal (CC) and mediolateral oblique (MLO) views were simulated without any intervention for three scenarios: radiographer/patient with similar statures, radiographer smaller than patient and radiographer taller than patient. Actions were taken to modify the postures: seated radiographer; patient on a step; seated patient; radiographer on a step. All the postures were analysed using kinovea 0.8.15 software and the angles were measured twice and classified according to European standard EN1005-4: 2005. The non-acceptable angles were measured mainly during MLO positioning when radiographer was taller than the patient: 139° and 120° for arm-flexion and abduction, 72° for trunk and -24° for head/neck-flexion. The introduction of alternative postures (radiographer seated), allowed improvements in posture (60° and 99° for arm flexion and abduction, 14° for trunk and 0° for head/neck flexion), being classified as acceptable. The alternative postures simulated have the potential to reduce the risk of developing WRMSDs when radiographers and patients have different statures. • Radiographers' postures in mammography can contribute to work-related musculoskeletal disorders • Non-acceptable posture was identified for MLO breast positioning (radiographer taller than patient) • Adapting posture to patient biotype reduces the WRMSD risk for radiographers.

  10. Chest radiograph interpretation by medical students

    International Nuclear Information System (INIS)

    Jeffrey, D.R.; Goddard, P.R.; Callaway, M.P.; Greenwood, R.

    2003-01-01

    AIM: To assess the ability of final year medical students to interpret conventional chest radiographs. MATERIALS AND METHODS: Ten conventional chest radiographs were selected from a teaching hospital radiology department library that were good radiological examples of common conditions. All were conditions that a medical student should be expected to recognize by the end of their training. One normal radiograph was included. The radiographs were shown to 52 final year medical students who were asked to describe their findings. RESULTS: The median score achieved was 12.5 out of 20 (range 6-18). There was no difference between the median scores of male and female students (12.5 and 12.3, respectively, p=0.82) but male students were more likely to be certain of their answers than female students (median certainty scores 23.0 and 14.0, respectively). The overall degree of certainty was low. On no radiograph were more than 25% of students definite about their answer. Students had received little formal radiology teaching (2-42 h, median 21) and few expressed an interest in radiology as a career. Only two (3.8%) students thought they were good at interpreting chest radiographs, 17 (32.7%) thought they were bad or awful. CONCLUSION: Medical students reaching the end of their training do not perform well at interpreting simple chest radiographs. They lack confidence and have received little formal radiological tuition. Perhaps as a result, few are interested in radiology as a career, which is a matter for concern in view of the current shortage of radiologists in the UK

  11. Radiographic markers - A reservoir for bacteria?

    International Nuclear Information System (INIS)

    Tugwell, Jenna; Maddison, Adele

    2011-01-01

    Introduction: Amongst the most frequently handled objects in the radiology department are radiographic markers. They are personal accessories used with every patient, and are kept in the radiographers pockets when not utilised. Upon enquiry it was discovered that many radiographers disregarded the potential of these accessories to become a vector for cross-contamination thus never or rarely clean them. The aims of this study were therefore to identify if radiographic markers are a reservoir for bacteria and to establish an effective cleaning method for decontaminating them. Methodology: 25 radiographers/student radiographers were selected for this study. Swabbing of their markers prior and post cleaning took place. The microbiology laboratory subsequently analyzed the results by quantifying and identifying the bacteria present. The participants also completed a closed questionnaire regarding their markers (e.g. frequency of cleaning and type of marker) to help specify the results gained from the swabbing procedure. Results: From the sample swabbed, 92% were contaminated with various organisms including Staphylococcus and Bacillus species, the amount of bacteria present ranged from 0 to >50 CFU. There were no significant differences between disinfectant wipes and alcohol gel in decontaminating the markers. Both successfully reduced their bacterial load, with 80% of the markers post cleaning having 0 CFU. Conclusion: The results indicated that radiographic markers can become highly contaminated with various organisms thus serve as a reservoir for bacteria. In addition, the markers need to be cleaned on a regular basis, with either disinfectant wipes or alcohol gel to reduce their bacterial load.

  12. Radiographic evaluation of marginal bone levels adjacent to parallel-screw cylinder machined-neck implants and rough-surfaced microthreaded implants using digitized panoramic radiographs.

    Science.gov (United States)

    Nickenig, Hans-Joachim; Wichmann, Manfred; Schlegel, Karl Andreas; Nkenke, Emeka; Eitner, Stephan

    2009-06-01

    The purpose of this split-mouth study was to compare macro- and microstructure implant surfaces at the marginal bone level during a stress-free healing period and under functional loading. From January to February 2006, 133 implants (70 rough-surfaced microthreaded implants and 63 machined-neck implants) were inserted in the mandible of 34 patients with Kennedy Class I residual dentitions and followed until February 2008. The marginal bone level was radiographically determined, using digitized panoramic radiographs, at four time points: at implant placement (baseline level), after the healing period, after 6 months of functional loading, and at the end of follow-up. The median follow-up time was 1.9 (range: 1.9-2.1) years. The machined-neck group had a mean crestal bone loss of 0.5 mm (range: 0-2.3) after the healing period, 0.8 mm after 6 months (range: 0-2.4), and 1.1 mm (range: 0-3) at the end of follow-up. The rough-surfaced microthreaded implant group had a mean bone loss of 0.1 mm (range: -0.4-2) after the healing period, 0.4 mm (range: 0-2.1) after 6 months, and 0.5 mm (range: 0-2.1) at the end of follow-up. The two implant types showed significant differences in marginal bone levels (healing period: P=0.01; end of follow-up: Pimplants showed that implants with the microthreaded design caused minimal changes in crestal bone levels during healing (stress-free) and under functional loading.

  13. Voice stress analysis and evaluation

    Science.gov (United States)

    Haddad, Darren M.; Ratley, Roy J.

    2001-02-01

    Voice Stress Analysis (VSA) systems are marketed as computer-based systems capable of measuring stress in a person's voice as an indicator of deception. They are advertised as being less expensive, easier to use, less invasive in use, and less constrained in their operation then polygraph technology. The National Institute of Justice have asked the Air Force Research Laboratory for assistance in evaluating voice stress analysis technology. Law enforcement officials have also been asking questions about this technology. If VSA technology proves to be effective, its value for military and law enforcement application is tremendous.

  14. Assessment of the willingness of radiographers in mammography to accept new responsibilities in role extension: Part one - Quantitative analysis

    Energy Technology Data Exchange (ETDEWEB)

    Moran, S., E-mail: sheila.moran@uon.edu.au [BreastScreen New South Wales, Hunter New England Program (Australia); Warren-Forward, H. [Discipline of Medical Radiation Sciences, University of Newcastle, NSW (Australia)

    2011-11-15

    Purpose: The success of skill development amongst radiographers in the UK over the last 30 years has stimulated discussion about similar developments in Australia. The introduction of flexible roles and responsibilities may well improve the recruitment and retention issues facing radiographers in mammography by increasing the level of job satisfaction and professional confidence. The main purpose of this study was to investigate the attitudes of BreastScreen Australia radiographers toward mammography screen reading and to determine other areas of interest in role extension. Methods and materials: Questionnaires were sent to radiographers working within Australian BreastScreening programs. The emphasis for this study was on image interpretation, although different areas of role expansion were discussed. The radiographers were asked whether there were any barriers preventing them from becoming screen readers and the levels of supervision and training they thought appropriate for different tasks.They were asked to discuss possible benefits and disadvantages of additional responsibilities. The involvement of radiographers with routine screening was explored as well as the possibility of further training leading to more diversity in their careers. Results: The results highlight the interest that radiographers working in Australia have for role extension in mammography. The radiographers indicated they would feel reasonably confident to undertake image interpretation, but two areas gave them cause for concern - a lack of prior images, and the prospect of no radiologist reading with them. The majority (79%) of radiographers were prepared to undertake extra training and demonstrated that the importance of increased pay for these extra responsibilities (39%) lagged behind the importance of increased professional equity (47%) and increased enjoyment and interest in mammography (66%). The possibility of role expansion being a cause of division in the workforce (pressure to

  15. Assessment of the willingness of radiographers in mammography to accept new responsibilities in role extension: Part one - Quantitative analysis

    International Nuclear Information System (INIS)

    Moran, S.; Warren-Forward, H.

    2011-01-01

    Purpose: The success of skill development amongst radiographers in the UK over the last 30 years has stimulated discussion about similar developments in Australia. The introduction of flexible roles and responsibilities may well improve the recruitment and retention issues facing radiographers in mammography by increasing the level of job satisfaction and professional confidence. The main purpose of this study was to investigate the attitudes of BreastScreen Australia radiographers toward mammography screen reading and to determine other areas of interest in role extension. Methods and materials: Questionnaires were sent to radiographers working within Australian BreastScreening programs. The emphasis for this study was on image interpretation, although different areas of role expansion were discussed. The radiographers were asked whether there were any barriers preventing them from becoming screen readers and the levels of supervision and training they thought appropriate for different tasks.They were asked to discuss possible benefits and disadvantages of additional responsibilities. The involvement of radiographers with routine screening was explored as well as the possibility of further training leading to more diversity in their careers. Results: The results highlight the interest that radiographers working in Australia have for role extension in mammography. The radiographers indicated they would feel reasonably confident to undertake image interpretation, but two areas gave them cause for concern - a lack of prior images, and the prospect of no radiologist reading with them. The majority (79%) of radiographers were prepared to undertake extra training and demonstrated that the importance of increased pay for these extra responsibilities (39%) lagged behind the importance of increased professional equity (47%) and increased enjoyment and interest in mammography (66%). The possibility of role expansion being a cause of division in the workforce (pressure to

  16. Reference Neutron Radiographs of Nuclear Reactor Fuel

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Reference neutron radiographs of nuclear reactor fuel were produced by the Euraton Neutron Radiography Working Group and published in 1984 by the Reidel Publishing Company. In this collection a classification is given of the various neutron radiographic findings, that can occur in different parts...... of pelletized, annular and vibro-conpacted nuclear fuel pins. Those parts of the pins are shown where changes of appearance differ from those for the parts as fabricated. Also radiographs of those as fabricated parts are included. The collection contains 158 neutron radiographs, reproduced on photographic paper...

  17. Transfer of learning: Radiographers' perceptions of simulation-based educational intervention

    International Nuclear Information System (INIS)

    Aura, S.; Jordan, S.; Saano, S.; Tossavainen, K.; Turunen, H.

    2016-01-01

    Aim: The aims of this qualitative descriptive study were to 1) explore and define radiographers' competence in intravenous pharmacotherapy before and after a simulation-based education, 2) examine radiographer's perceptions of transfer of learning into clinical practice. Method: Sixteen diagnostic radiographers in one hospitals' Clinical Radiology Unit were individually interviewed before a multidisciplinary simulation-based pharmacotherapy education intervention in 2012 and fourteen were re-interviewed after the intervention 6–7 months later. Data were analyzed using qualitative content analysis. Results: Before education the participants reported uncertain competence in pain management during imaging procedures and acute situations. These weak competence areas identified were strengthened and self-confidence grew. The intervention improved the domains of pharmacotherapy-related patient safety; teamwork development and communication skills. In addition, the radiographers indicated that the iv. pharmacotherapy knowledge from simulation learning was transferred to routine work. Conclusion: The results of this study suggest simulation-based education is suitable for radiographers' pharmacotherapy learning. Adequate pain measurement and management are essential during invasive procedures and these skills can be realistically learned in simulations and transferred to clinical practice. - Highlights: • Simulation education is suitable for professionals' pharmacotherapy education. • Radiographers felt education empowered them to manage acute situations. • Skills in pain measurement, analgesia and patient monitoring enhanced. • Communication and teamwork skills were enhanced. • Simulation-based learning was transferred to clinical practice.

  18. Diagnostic value of the chest radiograph in asymptomatic neonates with a cardiac murmur

    International Nuclear Information System (INIS)

    Oeppen, R.S.; Fairhurst, J.J.; Argent, J.D.

    2002-01-01

    AIM: To establish the diagnostic accuracy and diagnostic usefulness of the chest radiograph in asymptomatic neonates with cardiac murmurs. PATIENTS AND METHODS: The chest radiographs of 68 asymptomatic neonates with cardiac murmurs were analysed retrospectively. The radiographs were anonymized and then evaluated for the presence or absence of cardiac disease by six radiologists, three who regularly interpret neonatal chest radiographs and three who do so infrequently. The eventual diagnosis for each neonate and the impact of the chest radiograph and original report on patient management were established by review of the clinical case notes. RESULTS: The results for each observer were expressed in 2 x 2 contingency tables and statistical analysis was performed using Fisher's exact test. The radiologists who were experienced in reporting neonatal chest radiographs achieved statistically significant results (P = 0.003, P = 0.002 andP = 0.007) compared with those who were less experienced (P = 0.13, P = 0.16 andP = 0.09). Review of the case notes established that the chest radiograph and original report did not influence clinical management in any of the 68 cases studied. CONCLUSIONS: Radiologists who frequently report neonatal chest radiographs achieve high accuracy in differentiating cardiac from non-cardiac disease. However, inaccuracies are unavoidable as radiological evidence of cardiac disease is often not present. A false-positive result could cause undue anxiety while a false-negative report could result in the omission of further investigations. Furthermore, a chest radiograph is unlikely to provide the definitive diagnosis. Chest radiographs did not appear to influence patient management in this study and cannot be recommended in the initial evaluation of the asymptomatic neonate with a heart murmur. Oeppen, R.S. et al. (2002)

  19. Radiographic features of tuberculous osteitis in greater trochanter and lschium

    International Nuclear Information System (INIS)

    Hahm, So Hee; Lee, Ye Ri; Kim, Dong Jin; Sung, Ki Jun; Lim, Jong Nam

    1996-01-01

    To evaluate, if possible, the radiographic features of tuberculous osteitis in the greater trochanter and ischium, and to determine the cause of the lesions. We reterospectively reviewed the plain radiographic findings of 14 ptients with histologically proven tuberculous osteitis involving the greater trochanter and ischium. In each case, the following were analyzed:morphology of bone destruction, including cortical erosion;periosteal reaction;presence or abscence of calcific shadows in adjacent soft tissue. On the basis of an analysis of radiographic features and correlation of the anatomy with adjacent structures we attempted to determine causes. Of the 14 cases evaluated, 12 showed varrious degrees of extrinsic erosion on the outer cortical bone of the greater trochanter and ischium ; in two cases, bone destruction was so severe that the radiographic features of advanced perforated osteomyelitis were simulated. In addition to findings of bone destruction, in these twelve cases, the presence of sequestrum or calcific shadows was seen in adjacent soft tissue. Tuberculous osteitis in the greater trochanter and ischium showed the characteristic findings of chronic extrinsic erosion. On the basis of these findings we can suggest that these lesions result from an extrinsic pathophysiologic cause such as adjacent bursitis

  20. Radiographic features of tuberculous osteitis in greater trochanter and lschium

    Energy Technology Data Exchange (ETDEWEB)

    Hahm, So Hee; Lee, Ye Ri [Hanil Hospital Affiliated to KEPCO, Seoul (Korea, Republic of); Kim, Dong Jin; Sung, Ki Jun [Yonsei Univ. Wonju College of Medicine, Wonju (Korea, Republic of); Lim, Jong Nam [Konkuk Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-11-01

    To evaluate, if possible, the radiographic features of tuberculous osteitis in the greater trochanter and ischium, and to determine the cause of the lesions. We reterospectively reviewed the plain radiographic findings of 14 ptients with histologically proven tuberculous osteitis involving the greater trochanter and ischium. In each case, the following were analyzed:morphology of bone destruction, including cortical erosion;periosteal reaction;presence or abscence of calcific shadows in adjacent soft tissue. On the basis of an analysis of radiographic features and correlation of the anatomy with adjacent structures we attempted to determine causes. Of the 14 cases evaluated, 12 showed varrious degrees of extrinsic erosion on the outer cortical bone of the greater trochanter and ischium ; in two cases, bone destruction was so severe that the radiographic features of advanced perforated osteomyelitis were simulated. In addition to findings of bone destruction, in these twelve cases, the presence of sequestrum or calcific shadows was seen in adjacent soft tissue. Tuberculous osteitis in the greater trochanter and ischium showed the characteristic findings of chronic extrinsic erosion. On the basis of these findings we can suggest that these lesions result from an extrinsic pathophysiologic cause such as adjacent bursitis.

  1. Flaw acceptance criteria taking into consideration the NDT: radiographic and ultrasonic testing. Analysis through the fracture mechanics methods

    International Nuclear Information System (INIS)

    Capurro, E.; Alicino, F.; Corvi, A.

    1993-01-01

    The present study compares and evaluates the flaw acceptance criteria of the non-destructive inspections meeting European Community standards, through the application of the fracture mechanics methods that were determined and verified by the previous activity. Some choices were made; these, however, do not change the general validity of the conclusions. Shaved full-penetration butt welds of Class 1 components making up the primary circuit were considered and the following parameters varied: standards: French, German, Italian (ASME III) and UK; material: AISI 316 and low alloy steel A 533; base material and weld metal; temperature: RT, 370 deg C for the austenitic and 260 deg C for the ferritic steel; ultrasonic and radiographic methods; defect position: surface and internal; stress condition: situations with different primary and secondary stresses. From a preliminary examination of this study it is evident that the large quantity of results available and the abundance of information contained therein make a simple and exhaustive synthesis difficult. In fact, different analyses are possible and we have, therefore, limited the research to activities to perform a comparison and a general evaluation of the acceptance criteria of the non-destructive testing. (authors). 57 refs., 25 figs., 11 tabs

  2. Computer assisted analysis of hand radiographs in infantile hypophosphatasia carriers

    International Nuclear Information System (INIS)

    Chodirker, B.N.; Greenberg, C.R.; Manitoba Univ., Winnipeg, MB; Roy, D.; Cheang, M.; Evans, J.A.; Manitoba Univ., Winnipeg, MB; Manitoba Univ., Winnipeg, MB; Reed, M.H.; Manitoba Univ., Winnipeg, MB

    1991-01-01

    Hand radiographs of 49 carriers of infantile hypophosphatasia and 67 non-carriers were evaluated using two Apple IIe Computer Programs and Apple Graphics Tablet. CAMPS was used to determine the bone lengths and calculate the metacarpophalangeal profiles. A newly developed program (ADAM) was used to determine bone density based on percent cortical area of the second metacarpal. Carriers of infantile hypophosphatasia had significantly less dense bones. (orig.)

  3. The Reliability of Assessing Radiographic Healing of Osteochondritis Dissecans of the Knee.

    Science.gov (United States)

    Wall, Eric J; Milewski, Matthew D; Carey, James L; Shea, Kevin G; Ganley, Theodore J; Polousky, John D; Grimm, Nathan L; Eismann, Emily A; Jacobs, Jake C; Murnaghan, Lucas; Nissen, Carl W; Myer, Gregory D; Weiss, Jennifer; Edmonds, Eric W; Anderson, Allen F; Lyon, Roger M; Heyworth, Benton E; Fabricant, Peter D; Zbojniewicz, Andy

    2017-05-01

    The reliability of assessing healing on plain radiographs has not been well-established for knee osteochondritis dissecans (OCD). To determine the inter- and intrarater reliability of specific radiographic criteria in judging healing of femoral condyle OCD. Cohort study (Diagnosis); Level of evidence, 3. Ten orthopedic sports surgeons rated the radiographic healing of 30 knee OCD lesions at 2 time points, a minimum of 1 month apart. First, raters compared pretreatment and 2-year follow-up radiographs on "overall healing" and on 5 subfeatures of healing, including OCD boundary, sclerosis, size, shape, and ossification using a continuous slider scale. "Overall healing" was also rated using a 7-tier ordinal scale. Raters then compared the same 30 pretreatment knee radiographs in a stepwise progression to the 2-, 4-, 7-, 12-, and 24-month follow-up radiographs on "overall healing" using a continuous slider scale. Interrater and intrarater reliability were assessed using intraclass correlations (ICC) derived from a 2-way mixed effects analysis of variance for absolute agreement. Overall healing of the OCD lesions from pretreatment to 2-year follow-up radiographs was rated with excellent interrater reliability (ICC = 0.94) and intrarater reliability (ICC = 0.84) when using a continuous scale. The reliability of the 5 subfeatures of healing was also excellent (interrater ICCs of 0.87-0.89; intrarater ICCs of 0.74-0.84). The 7-tier ordinal scale rating of overall healing had lower interrater (ICC = 0.61) and intrarater (ICC = 0.68) reliability. The overall healing of OCD lesions at the 5 time points up to 24 months had interrater ICCs of 0.81-0.88 and intrarater ICCs of 0.65-0.70. Interrater reliability was excellent when judging the overall healing of OCD femoral condyle lesions on radiographs as well as on 5 specific features of healing on 2-year follow-up radiographs. Continuous scale rating of OCD radiographic healing yielded higher reliability than the ordinal scale

  4. Digital interactive learning of oral radiographic anatomy.

    Science.gov (United States)

    Vuchkova, J; Maybury, T; Farah, C S

    2012-02-01

    Studies reporting high number of diagnostic errors made from radiographs suggest the need to improve the learning of radiographic interpretation in the dental curriculum. Given studies that show student preference for computer-assisted or digital technologies, the purpose of this study was to develop an interactive digital tool and to determine whether it was more successful than a conventional radiology textbook in assisting dental students with the learning of radiographic anatomy. Eighty-eight dental students underwent a learning phase of radiographic anatomy using an interactive digital tool alongside a conventional radiology textbook. The success of the digital tool, when compared to the textbook, was assessed by quantitative means using a radiographic interpretation test and by qualitative means using a structured Likert scale survey, asking students to evaluate their own learning outcomes from the digital tool. Student evaluations of the digital tool showed that almost all participants (95%) indicated that the tool positively enhanced their learning of radiographic anatomy and interpretation. The success of the digital tool in assisting the learning of radiographic interpretation is discussed in the broader context of learning and teaching curricula, and preference (by students) for the use of this digital form when compared to the conventional literate form of the textbook. Whilst traditional textbooks are still valued in the dental curriculum, it is evident that the preference for computer-assisted learning of oral radiographic anatomy enhances the learning experience by enabling students to interact and better engage with the course material. © 2011 John Wiley & Sons A/S.

  5. Mandibular ramus: A predictor for sex determination - A digital radiographic study

    Directory of Open Access Journals (Sweden)

    Kotya Naik Maloth

    2017-01-01

    Full Text Available Aim: To evaluate mandibular ramus linear measurements on digital panoramic radiographs and to assess the usefulness of mandibular ramus in sex determination. Material and Methods: A retrospective study was conducted on 100 patients (50 males and 50 females using digital panoramic radiographs of Khammam population with age ranging from 20 to 50 years. Standard digital panoramic radiographs were taken without any errors by Sirona, ORTHOPHOS XG 5 machine. The following five mandibular linear measurements were performed in cm such as upper ramus breadth, lower ramus breadth, condylar ramus height, projective ramus height, and coronoid ramus height. The obtained data were analyzed with the software SPSS 13.0 for statistical analysis using discriminate methods. Results: In the present study, all the linear measurements of mandibular ramus on digital panoramic radiographs showed a statistically significant difference between the genders. Conclusion: We conclude that the use of mandibular ramus is recommended as an aid for sex determination in forensic science due to their unique feature of sexual dimorphism.

  6. Radiographic manifestations of hypochondroplasia

    Energy Technology Data Exchange (ETDEWEB)

    Heselson, N G; Cremin, B J [Groote Schuur Hospital, Cape Town (South Africa); Beighton, P

    1979-01-01

    Hypochrondroplasia is an inherited skeletal dysplasia that resembles achondroplasia in mild degree. Radiographic manifestations encountered in 12 affected individuals in South Africa include slight shortening of all segments of the tubular bones, moderate caudal diminution of the lumbar interpedicular distances, increased lumbar lordosis with cacral tilt and distal prolongation of the fibular. Hypochondroplasia can be distinguished from other osteochondrodystrophies such as achondroplasia, pseudo-achondroplasia and metaphyseal chondroplasia by the recognition of it clinical and radiographic manifestations.

  7. Prototype system for enhancement of frontal chest radiographs using eigenimage processing

    International Nuclear Information System (INIS)

    Butler, A.; Bones, P.; Hurrell, M.

    2008-01-01

    A prototype system is described for enhancement of radiographic images in the eigen domain. The images chosen to enhance are frontal chest radiographs. This class of images has been chosen because it is both a clinically important examination and an example of the high-resolution images used within radiology. The enhancement method is based on principal components analysis, a multivariate statistical technique first used within image processing for face recognition. The method requires a training set of normal images to identify normal patterns of variance. The enhancement process then removes these normal patterns of variance, often increasing the relative intensity of pathologies. Enhanced images presented in this paper include a range of common pathologies found on chest radiographs. Details of implementation, computing expense and possible applications within radiology are discussed.

  8. Intra-articular hip injection: does pain relief correlate with radiographic severity of osteoarthritis?

    International Nuclear Information System (INIS)

    Deshmukh, Ajit J.; Rodriguez, Jose A.; Panagopoulos, Georgia; Alizadeh, Ahmadreza; Klein, Devon A.

    2011-01-01

    Intra-articular injection is being used widely for both diagnostic and therapeutic purposes in the hip. However, its efficacy is not always predictable in patients with hip osteoarthritis (OA). The purpose of this study was to determine whether the degree of radiographic severity of OA was predictive of the response to intra-articular injection of local anesthetic with corticosteroid and to determine the relationship between immediate pain relief resulting from the anesthetic and delayed pain relief resulting from corticosteroid administration. This retrospective study included 217 patients (220 injections) with diagnosis of hip OA who underwent a fluoroscopically guided therapeutic hip injection of local anesthetic and corticosteroid. Hip radiographs were scored using the Kellgren-Lawrence scale. Immediate and delayed pain relief was documented using a visual analog scale. Logistic regression analysis was performed to investigate whether age, gender or radiographic severity of OA were independent predictors of pain relief. Degree of agreement between immediate and delayed response was assessed with the kappa coefficient. Immediate pain relief was reported in 68.2% of hips and delayed relief in 71.4% of hips. A high level of agreement was observed between immediate and delayed pain relief (kappa = 0.80, p < 0.001). 94% of patients reporting immediate relief also reported relief 2 weeks later. Univariate and multivariate analysis revealed that neither gender nor age was related to immediate or delayed pain relief. Only severity of OA (based on radiographic analysis) was observed to be predictive of pain relief. Pain relief following intra-articular hip injection correlated with radiographic severity of OA. This intervention may be of therapeutic and prognostic value in patients awaiting hip arthroplasty. (orig.)

  9. Consultant radiographers: Profile of the first generation

    International Nuclear Information System (INIS)

    Forsyth, Lesley J.; Maehle, Valerie

    2010-01-01

    Aim: The aim of this research is to examine the profile of first generation consultant radiographers: their demographics, educational backgrounds, qualifications and training, career experience and progression, teaching, lecturing and research activities. Method: Participant recruitment was drawn from the Society and College of Radiographers consultant radiographer group. Data collection involved a self-administered paper based and web based questionnaire. Results: Participant response rate of 55% (n = 11). Conclusions: The profile of the first consultant radiographer cohort reflects a diverse and eclectic mix. While some aspects of their development such as educational background, clinical training and skills enhancement are comparable to nurse consultants, clinical experience and employment history show some differences. Commitment to development of expert clinical skills is evident within the profile of the first generation cohort of consultant radiographers however research and leadership training are not strong features.

  10. Consultant radiographers: Profile of the first generation

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, Lesley J., E-mail: l.forsyth@rgu.ac.u [School of Health Sciences, Robert Gordon University, Aberdeen, AB10 7QG (United Kingdom); Maehle, Valerie [Faculty of Health and Social Care, Robert Gordon University, Aberdeen, AB10 7QG (United Kingdom)

    2010-11-15

    Aim: The aim of this research is to examine the profile of first generation consultant radiographers: their demographics, educational backgrounds, qualifications and training, career experience and progression, teaching, lecturing and research activities. Method: Participant recruitment was drawn from the Society and College of Radiographers consultant radiographer group. Data collection involved a self-administered paper based and web based questionnaire. Results: Participant response rate of 55% (n = 11). Conclusions: The profile of the first consultant radiographer cohort reflects a diverse and eclectic mix. While some aspects of their development such as educational background, clinical training and skills enhancement are comparable to nurse consultants, clinical experience and employment history show some differences. Commitment to development of expert clinical skills is evident within the profile of the first generation cohort of consultant radiographers however research and leadership training are not strong features.

  11. Interpretation and evaluation of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    After digestion, the interpreter must interpreted and evaluate the image on film, usually many radiograph stuck in this step, if there is good density, so there are no problem. This is a final stage of radiography work and this work must be done by level two or three radiographer. This is a final stages before the radiographer give a result to their customer for further action. The good interpreter must know what kind of artifact, is this artifact are dangerous or not and others. In this chapter, the entire artifact that usually showed will be discussed briefly with the good illustration and picture to make the reader understand and know the type of artifact that exists.

  12. Cough urethrocystography: The best radiological evaluation of female stress urinary incontinence?

    International Nuclear Information System (INIS)

    Varpula, M.; Maekinen, J.; Kiilholma, P.

    1989-01-01

    Urethrocystography and simultaneous urethrocystometry were performed on 40 women with primary urinary incontinence. The posterior urethrovesical angle, inclination angle, urethropelvic angle, and an orifice descent angle, not earlier described, were measured on radiographs obtained at rest, during coughing and during straining. The orifice descent angle was used to describe the descent of the internal urethral orifice in the cough radiographs, and was the only measurement that provided a significant correlation with urethrocystometry. The other angles measured, and radiographs obtained at rest or during straining were not useful in the evaluation of female stress urinary incontinence. The authors conclude that the best imaging method for the evaluation of female stress urinary incontinence is urethrocystography employing a single lateral view taken during coughing, with measurement of the orifice descent angle. (orig.)

  13. Training radiographers to deliver an intervention to promote early presentation of breast cancer

    International Nuclear Information System (INIS)

    Burgess, Caroline; Teasdale, Emma; Omar, Lynne; Tucker, Lorraine; Ramirez, Amanda-Jane

    2012-01-01

    Aim: To evaluate the feasibility of training sufficient radiographers to deliver an intervention to promote early presentation of breast cancer to all older women attending for their final routine mammogram within the NHS Breast Screening Programme. If the Promoting Early Presentation (PEP) intervention is demonstrated to be cost-effective, it may be implemented across the NHS requiring at least four radiographers per screening service to deliver the intervention. Methods: A pilot study in a single breast screening service was conducted to assess the feasibility of training sufficient radiographers to meet this objective. Quantitative and qualitative methods were used to evaluate the impact of training on participating radiographers and the screening service. Competency to deliver the intervention was assessed at key points during training according to quality criteria based on delivery of the key messages and style of delivery. Confidence to deliver the intervention was assessed using a self-report measure before and after training. Radiographers' experiences of training were elicited in face-to-face qualitative interviews. Results: Seven of eight radiographers who were released to undertake the training achieved the required level of competency to deliver the intervention within four months. All improved over time in their confidence to deliver the key messages of the intervention. The qualitative analysis revealed the benefits and challenges of training from the perspective of the radiographers. Conclusion: It was feasible and acceptable to train sufficient radiographers to deliver the PEP Intervention. The training package will be streamlined to improve efficiency for large implementation trials and clinical practice across the NHS.

  14. Animal radiographs

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This chapter presents historical x rays of a wide variety of animals taken within 5 years of the discovery of x radiation. Such photos were used as tests or as illustrations for radiographic publications. Numerous historical photographs are included. 10 refs

  15. Observer performance in detecting multiple radiographic signals: prediction and analysis using a generalized ROC approach

    International Nuclear Information System (INIS)

    Metz, C.E.; Starr, S.J.; Lusted, L.B.

    1975-01-01

    The theories of decision processes and signal detection provide a framework for the evaluation of observer performance. Some radiologic procedures involve a search for multiple similar lesions, as in gallstone or pneumoconiosis examinations. A model is presented which attempts to predict, from the conventional receiver operating characteristic (ROC) curve describing the detectability of a single visual signal in a radiograph, observer performance in an experiment requiring detection of more than one such signal. An experiment is described which tests the validity of this model for the case of detecting the presence of zero, one, or two low-contrast radiographic images of a two-mm.-diameter lucite bead embedded in radiographic mottle. Results from six observers, including three radiologists, confirm the validity of the model and suggest that human observer performance for relatively complex detection tasks can be predicted from the results of simpler experiments

  16. Evaluation of trabecular bone patterns on dental radiographic images: influence of cortical bone

    Science.gov (United States)

    Amouriq, Yves; Evenou, Pierre; Arlicot, Aurore; Normand, Nicolas; Layrolle, Pierre; Weiss, Pierre; Guédon, Jean-Pierre

    2010-03-01

    For some authors trabecular bone is highly visible in intraoral radiographs. For other authors, the observed intrabony trabecular pattern is a representation of only the endosteal surface of cortical bone, not of intermedullary striae. The purpose of this preliminary study was to investigate the true anatomical structures that are visible in routine dental radiographs and classically denoted trabecular bone. This is a major point for bone texture analysis on radiographs. Computed radiography (CR) images of dog mandible section in molar region were compared with simulations calculated from high-resolution micro-CT volumes. Calculated simulations were obtained using the Mojette Transform. By digitally editing the CT volume, the simulations were separated into trabecular and cortical components into a region of interest. Different images were compared and correlated, some bone micro-architecture parameters calculated. A high correlation was found between computed radiographs and calculated simulations from micro-CT. The Mojette transform was successful to obtain high quality images. Cortical bone did not contribute to change in a major way simulated images. These first results imply that intrabony trabecular pattern observed on radiographs can not only be a representation of the cortical bone endosteal surface and that trabecular bone is highly visible in intraoral radiographs.

  17. Brazilian young dental practitioners' use and acceptance of digital radiographic examinations

    International Nuclear Information System (INIS)

    Rovaris, Karla; De Faria Vasconcelos, Karla; Do Nascimento, Eduarda Helena Leandro; Oliveira, Matheus Lima; Freitas, Deborah Queiroz; Haiter-Neto, Francisco

    2016-01-01

    The aim of this study was to investigate the use and acceptance of digital radiographic examinations by Brazilian dental practitioners in daily practice and to evaluate the advances that have occurred over the past 5 years. Dental practitioners enrolled in extension courses at the Piracicaba Dental School, University of Campinas, Brazil, responded to a self-administered questionnaire in the years 2011 and 2015. They were asked about sociodemographic factors and their knowledge and use of digital radiographic examinations. Descriptive analysis was performed, as well as the chi-square and Fisher exact tests, with a significance level of 5% (α=0.05). A total of 181 participants responded to the questionnaire in the years 2011 and 2015. Most of the respondents worked in private practice, had graduated within the last 5 years, and were between 20 and 30 years old. In 2011, 55.6% of respondents reported having ever used digital radiographic examinations, while in 2015 this number increased significantly to 85.4% (p<.0001), out of which 71.4% preferred it to conventional images. Moreover, 21.4% of respondents reported having used digital radiographic examinations for more than 3 years. A significant increase in use of intraoral digital radiography (p=0.0316) was observed in 2015. In both years, image quality and high cost were indicated, respectively, as the main advantage and disadvantage of digital radiographic examinations. This study showed that digital radiology has become more common in Brazil over the past 5 years. Most of the Brazilian dental practitioners evaluated in 2015 used digital radiographic examinations

  18. Brazilian young dental practitioners' use and acceptance of digital radiographic examinations.

    Science.gov (United States)

    Rovaris, Karla; de Faria Vasconcelos, Karla; do Nascimento, Eduarda Helena Leandro; Oliveira, Matheus Lima; Freitas, Deborah Queiroz; Haiter-Neto, Francisco

    2016-12-01

    The aim of this study was to investigate the use and acceptance of digital radiographic examinations by Brazilian dental practitioners in daily practice and to evaluate the advances that have occurred over the past 5 years. Dental practitioners enrolled in extension courses at the Piracicaba Dental School, University of Campinas, Brazil, responded to a self-administered questionnaire in the years 2011 and 2015. They were asked about sociodemographic factors and their knowledge and use of digital radiographic examinations. Descriptive analysis was performed, as well as the chi-square and Fisher exact tests, with a significance level of 5% (α=0.05). A total of 181 participants responded to the questionnaire in the years 2011 and 2015. Most of the respondents worked in private practice, had graduated within the last 5 years, and were between 20 and 30 years old. In 2011, 55.6% of respondents reported having ever used digital radiographic examinations, while in 2015 this number increased significantly to 85.4% (p<.0001), out of which 71.4% preferred it to conventional images. Moreover, 21.4% of respondents reported having used digital radiographic examinations for more than 3 years. A significant increase in use of intraoral digital radiography (p=0.0316) was observed in 2015. In both years, image quality and high cost were indicated, respectively, as the main advantage and disadvantage of digital radiographic examinations. This study showed that digital radiology has become more common in Brazil over the past 5 years. Most of the Brazilian dental practitioners evaluated in 2015 used digital radiographic examinations.

  19. Radiographic signs and diagnosis of dental disease

    International Nuclear Information System (INIS)

    Bellows, J.

    1993-01-01

    Dental radiographs are critical for the complete assessment and treatment of dental diseases. Dental radiography is commonly used to evaluate congenital dental defects, periodontal disease, orthodontic manipulations, oral tumors, endodontic treatments, oral trauma, and any situation where an abnormality is suspected. Although standard radiographic equipment and film can be used to produce dental radiographs, dental X-ray equipment and film provide superior quality images and greater convenience of animal patient positioning. An understanding of normal dental radiographic anatomy is important when interpreting dental radiographs. Stage III periodontitis is the earliest stage of periodontal disease at which radiographic abnormalities become apparent. Bone loss associated with periodontal disease can be classified as either horizontal or vertical. Periapical radiolucencies can represent granulomas, cysts, or abscesses, whereas periapical radiodensities may represent sclerotic bone or condensing osteitis. Lytic lesions of the bone of the jaw often represent oral neoplasms. Neoplasms also can displace or disrupt teeth in the dental arch. Resorptive lesions can be external or internal and appear as radiolucent areas involving the external surface of the root or the pulp cavity, respectively. Feline dental resorptive lesions, also known as odontoclastic resorptions, are a specific form of dental resorptive lesions unique to cats

  20. Radiographic heart-volume estimation in normal cats

    International Nuclear Information System (INIS)

    Ahlberg, N.E.; Hansson, K.; Svensson, L.; Iwarsson, K.

    1989-01-01

    Heart volume mensuration was evaluated on conventional radiographs from eight normal cats in different body positions using computed tomography (CT). Heart volumes were calculated from orthogonal thoracic radiographs in ventral and dorsal recumbency and from radiographs exposed with a vertical X-ray beam in dorsal and lateral recumbency using the formula for an ellipsoid body. Heart volumes were also estimated with CT in ventral, dorsal, right lateral and left lateral recumbency. No differences between heart volumes from CT in ventral recumbency and those from CT in right and left lateral recumbency were seen. In dorsal recumbency, however, significantly lower heart volumes were obtained. Heart volumes from CT in ventral recumbency were similar to those from radiographs in ventral and dorsal recumbency and dorsal/left lateral recumbency. Close correlation was also demonstrated between heart volumes from radiographs in dorsal/ left lateral recumbency and body weights of the eight cats

  1. Radiographic Severity of Rheumatoid Arthritis in African-Americans: Results from the CLEAR Registry

    Science.gov (United States)

    Bridges, S. Louis; Causey, Zenoria L.; Burgos, Paula I.; Huynh, B. Quynh N.; Hughes, Laura B.; Danila, Maria I.; van Everdingen, Amalia; Ledbetter, Stephanie; Conn, Doyt L.; Tamhane, Ashutosh; Westfall, Andrew O.; Jonas, Beth L.; Callahan, Leigh F.; Smith, Edwin A.; Brasington, Richard; Moreland, Larry W.; Alarcón, Graciela S.; van der Heijde, Désirée M.

    2010-01-01

    Objective To describe radiographic changes in African-Americans with rheumatoid arthritis (RA) from the CLEAR (Consortium for the Longitudinal Evaluation of African-Americans with Early Rheumatoid Arthritis) Registry, a multicenter observational study. Methods Self-declared African-American patients, were enrolled in CLEAR I, a longitudinal cohort of early RA (disease duration <2 years) from 2000 to 2005; or in CLEAR II, a cross-sectional cohort (any disease duration), from 2006 to the present. Demographic and clinical data were obtained, and sets of hand/wrist and foot radiographs were scored using the modified Sharp/van der Heijde scoring system. Results A total of 357 and 418 patients, respectively, have been enrolled into CLEAR I and CLEAR II. We report here an interim analysis of radiographic severity in these patients. For the CLEAR I cohort, 294 patients had a mean radiographic score of 2.89 at the baseline visit; 32.0% showed either erosions (25.9%) or joint space narrowing (JSN) (19.4%). At the 36-month visit the mean score was 5.65; 44.2% had erosions, 41.5% JSN and 55.4% had either. Among those patients without radiographic damage at baseline, 18.9% had progressed at the 36-month visit, compared to 57.1% of those with baseline damage (p<0.0001). For the CLEAR II cohort, 167 patients with RA of any duration, 65.3% exhibited joint erosions, 65.3% JSN and 74.8% exhibited either. The mean radiographic score was 33.42. Conclusion This is the largest radiographic study of African American RA patients. Damage occurs early in the disease and is associated with radiographic progression at 3 years of disease duration. The CLEAR Registry will provide a valuable resource for future analyses of genetic, clinical, and environmental factors associated with radiographic severity of RA in African-Americans. PMID:20461784

  2. The lambda sign: a new radiographic indicator of latent syndesmosis instability.

    Science.gov (United States)

    Ryan, Ltc Paul; Hills, Maj Chad; Chang, James; Wilson, Cpt David

    2014-09-01

    Latent syndesmotic instability is a common cause of chronic ankle pain. The diagnosis is not readily apparent on static imaging as the fibula remains reduced. The hypothesis of this study was that a previously undescribed novel finding on coronal MRI (lambda sign) is an independent indicator of latent syndesmosis instability. We also report on the utility of classic radiographic and physical exam findings. A total of 23 patients with latent syndesmotic instability diagnosed via arthroscopy (group I) were compared to a cohort of 40 patients who were found to have a stable syndesmosis during arthroscopy for unrelated conditions (group II). A retrospective chart review was performed evaluating their clinical history, preoperative physical examination, and radiologic findings. The lambda sign is a high intensity signal seen on coronal MR imaging that resembles the Greek letter lambda. All of the physical exam findings tested were statistically significant. Pain at the syndesmosis had the highest sensitivity (83%), while pain reproduced with the proximal squeeze test resulted in the highest specificity (89%). The external rotation stress test had the highest positive predictive value (75%). Of the radiographic examinations performed, only the lambda sign was found to have statistical significance with a sensitivity of 75% and a specificity of 63%. The presence of a lambda sign on the MRI of patients with physical exam findings suggestive of syndesmotic pain was highly sensitive (75%) and specific (85%). The lambda sign noted on the coronal MRI was both sensitive and specific for injuries involving greater than 2 mm of diastasis on arthroscopic stress examination of the syndesmosis. While neither the lambda sign nor any other finding on physical or radiographic examination represented an independent predictor of syndesmotic instability, the presence of a lambda sign in concert with positive physical exam findings might help health care providers determine which patients

  3. Radiographer involvement in mammography image interpretation: A survey of United Kingdom practice

    International Nuclear Information System (INIS)

    Culpan, A.M.

    2016-01-01

    Breast cancer is most often diagnosed using x-ray mammography. Traditionally mammography images have been interpreted and reported by medically qualified practitioners – radiologists. Due to radiologist workforce shortages in recent years some non-medical practitioners, radiographers, now interpret and report mammography images. The aims of this survey were to describe the characteristics and practices of radiographers who interpret and report mammography images in NHS hospitals in the UK, and in particular to establish the extent of their practice beyond low-risk asymptomatic screening cases. This service evaluation demonstrated that UK radiographers are interpreting and reporting images across the full spectrum of clinical indications for mammography including: low-risk population screening, symptomatic, annual surveillance, family history and biopsy/surgical cases. The survey revealed that radiographers are involved in a diverse range of single and double reading practices where responsibility for diagnostic decision making is shared or transferred between radiologists and/or other radiographers. Comparative analysis of sub-group data suggested that there might be differences in the characteristics and practices of radiographers who interpret only low-risk screening mammograms and those who interpret and report a wider range of cases. The findings of this survey provide a platform for further research to investigate how and why the roles and responsibilities of radiographers who interpret and report mammograms vary between organisations, between practitioners and across different examinations. Further research is also needed to explore the implications of variation in practice for patients, practitioners and service providers. - Highlights: • UK radiographers interpret mammograms across the full spectrum of clinical indications. • UK radiographers are involved in a wide range of single/double mammography reading practices. • Characteristics required for

  4. Advanced radiographic scanning, enhancement and electronic data storage

    International Nuclear Information System (INIS)

    Savoie, C.; Rivest, D.

    2003-01-01

    It is a well-known fact that radiographs deteriorate with time. Substantial cost is attributed to cataloguing and storage. To eliminate deterioration issues and save time retrieving radiographs, laser scanning techniques were developed in conjunction with viewing and enhancement software. This will allow radiographs to be successfully scanned and stored electronically for future reference. Todays radiographic laser scanners are capable Qf capturing images with an optical density of up to 4.1 at 256 grey levels and resolutions up to 4096 pixels per line. An industrial software interface was developed for the nondestructive testing industry so that, certain parameters such as scan resolution, number of scans, file format and location to be saved could be adjusted as needed. Once the radiographs have been scanned, the tiff images are stored, or retrieved into Radiance software (developed by Rivest Technologies Inc.), which will help to properly interpret the radiographs. Radiance was developed to allow the user to quickly view the radiographs correctness or enhance its defects for comparison and future evaluation. Radiance also allows the user to zoom, measure and annotate areas of interest. Physical cost associated with cataloguing, storing and retrieving radiographs can be eliminated. You can now successfully retrieve and view your radiographs from CD media or dedicated hard drive at will. For continuous searches and/or field access, dedicated hard drives controlled by a server would be the media of choice. All scanned radiographs will be archived to CD media (CD-R). Laser scanning with a proper acquisition interface and easy to use viewing software will permit a qualified user to identify areas of interest and share this information with his/her colleagues via e-mail or web data access. (author)

  5. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD).

    Science.gov (United States)

    Nitschke, Ashley; Lambert, Jeffery R; Glueck, Deborah H; Jesse, Mary Kristen; Mei-Dan, Omer; Strickland, Colin; Petersen, Brian

    2015-11-01

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p TAD (p TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain.

  6. Postoperative chest radiographic changes after on- and off-pump coronary surgery

    International Nuclear Information System (INIS)

    Narayan, P.; Caputo, M.; Jones, J.; Al-Tai, S.; Angelini, G.D.; Wilde, P.

    2005-01-01

    AIM: A variety of chest radiograph abnormalities are recognized after coronary artery bypass grafting (CABG). This study analyzes the appearance of preoperative and postoperative chest radiographs in two groups of patients undergoing myocardial revascularization with or without the use of cardiopulmonary bypass (CPB). METHODS: Chest radiographs (preoperative and at 1 day, 6 days and 6 to 8 weeks post operatively) were analyzed according to a detailed protocol in cases of conventional CABG on CPB (n=60) or off-pump coronary artery bypass (OPCAB) (n=60) surgery. On each film 17 different major potential postoperative abnormalities were analyzed. RESULTS: Clinical findings were similar in the two groups. Patients undergoing OPCAB surgery had decreased blood loss, decreased red cell and platelet transfusion, significantly lower intubation time and required less postoperative inotropic support compared with patients undergoing CPB. The CPB group had a significantly higher incidence of left band atelectasis than the OPCAB group (37.6% vs 17.5%, p=0.01) at 6 days postoperatively. There was no other statistically significant difference in any of the 16 remaining major chest radiograph findings between the two groups. CONCLUSION: Although OPCAB surgery is associated with improved clinical outcome compared with conventional CABG surgery, the analysis of postoperative chest radiographs demonstrated only a minor benefit as shown by a reduced degree of left band atelectasis in the OPCAB group

  7. Postoperative chest radiographic changes after on- and off-pump coronary surgery

    Energy Technology Data Exchange (ETDEWEB)

    Narayan, P. [Bristol Heart Institute, Bristol Royal Infirmary, Bristol (United Kingdom); Caputo, M. [Bristol Heart Institute, Bristol Royal Infirmary, Bristol (United Kingdom); Jones, J. [Department of Radiology, Bristol Royal Infirmary, Bristol (United Kingdom); Al-Tai, S. [Department of Radiology, Bristol Royal Infirmary, Bristol (United Kingdom); Angelini, G.D. [Bristol Heart Institute, Bristol Royal Infirmary, Bristol (United Kingdom); Wilde, P. [Department of Radiology, Bristol Royal Infirmary, Bristol (United Kingdom)]. E-mail: peter.wilde@ubht.swest.nhs.uk

    2005-06-01

    AIM: A variety of chest radiograph abnormalities are recognized after coronary artery bypass grafting (CABG). This study analyzes the appearance of preoperative and postoperative chest radiographs in two groups of patients undergoing myocardial revascularization with or without the use of cardiopulmonary bypass (CPB). METHODS: Chest radiographs (preoperative and at 1 day, 6 days and 6 to 8 weeks post operatively) were analyzed according to a detailed protocol in cases of conventional CABG on CPB (n=60) or off-pump coronary artery bypass (OPCAB) (n=60) surgery. On each film 17 different major potential postoperative abnormalities were analyzed. RESULTS: Clinical findings were similar in the two groups. Patients undergoing OPCAB surgery had decreased blood loss, decreased red cell and platelet transfusion, significantly lower intubation time and required less postoperative inotropic support compared with patients undergoing CPB. The CPB group had a significantly higher incidence of left band atelectasis than the OPCAB group (37.6% vs 17.5%, p=0.01) at 6 days postoperatively. There was no other statistically significant difference in any of the 16 remaining major chest radiograph findings between the two groups. CONCLUSION: Although OPCAB surgery is associated with improved clinical outcome compared with conventional CABG surgery, the analysis of postoperative chest radiographs demonstrated only a minor benefit as shown by a reduced degree of left band atelectasis in the OPCAB group.

  8. Radiographic aspects of xeroradiography

    International Nuclear Information System (INIS)

    Rao, G.U.V.; Fatouros, P.P.

    1980-01-01

    The quality of a conventional radiographic image can be characterized in terms of five basic parameters; density, contrast, latitude, resolution and noise. Since xeroradiographic images exhibit very limited broad area contrasts, and image formation is predominantly due to edge enhancement, a straightforward description of image quality using the same five parameters is not adequate. A detailed study was made of the radiographic aspects of xeroradiography with special reference to mammography, and a summary of major findings to date with appropriate references to published papers is presented

  9. Radiologist perceptions of radiographer role development in Scotland

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, Lesley J. [School of Health Sciences, Robert Gordon University, Faculty of Health and Social Care, Garthdee Road, Garthdee, Aberdeen AB10 7QG (United Kingdom)]. E-mail: l.forsyth@rgu.ac.uk; Robertson, Elizabeth M. [Department of Radiology, Aberdeen Royal Infirmary, Foresterhill, Aberdeen AB25 2ZN (United Kingdom)]. E-mail: e.m.robertson@arh.grampian.scot.nhs.uk

    2007-02-15

    Aim: To survey the perceptions of the Scottish radiology community in relation to radiographer role development. Methods: A postal questionnaire was sent to all consultant radiologists recorded on the NHS Scotland database of consultants. Results: Response rate was 63%. (i) Respondents considered increased professional standing of radiographers, best use of manpower resources, reduced pressure on the service and improved recruitment and retention, as positive advantages of radiographer development. (ii) The potential impact on radiology specialist registrar training, lack of clear medico-legal responsibilities and radiographers recognising the limitations of their abilities were identified as the main areas of radiologist anxiety. (iii) Fifty-seven percent did not consider current post-registration radiography education and training resources adequate to underpin the requirement of developed roles. (iv) Barriers to radiographer development were identified as lack of radiography and radiology staff, suitable education, financial constraints, traditional views and resistance to change. (v) Eighty-two percent reported support for radiographer role development and willingness to participate actively in developments. Conclusion: Despite reservations Scottish radiologists are supportive of the development of radiography colleagues, however, guidance is required on the medico-legal and accountability aspects of radiographers assuming new roles. Radiologist involvement in education and training for new roles may increase their confidence and trust in radiographers to work within the limitations of their competency and training.

  10. Radiologist perceptions of radiographer role development in Scotland

    International Nuclear Information System (INIS)

    Forsyth, Lesley J.; Robertson, Elizabeth M.

    2007-01-01

    Aim: To survey the perceptions of the Scottish radiology community in relation to radiographer role development. Methods: A postal questionnaire was sent to all consultant radiologists recorded on the NHS Scotland database of consultants. Results: Response rate was 63%. (i) Respondents considered increased professional standing of radiographers, best use of manpower resources, reduced pressure on the service and improved recruitment and retention, as positive advantages of radiographer development. (ii) The potential impact on radiology specialist registrar training, lack of clear medico-legal responsibilities and radiographers recognising the limitations of their abilities were identified as the main areas of radiologist anxiety. (iii) Fifty-seven percent did not consider current post-registration radiography education and training resources adequate to underpin the requirement of developed roles. (iv) Barriers to radiographer development were identified as lack of radiography and radiology staff, suitable education, financial constraints, traditional views and resistance to change. (v) Eighty-two percent reported support for radiographer role development and willingness to participate actively in developments. Conclusion: Despite reservations Scottish radiologists are supportive of the development of radiography colleagues, however, guidance is required on the medico-legal and accountability aspects of radiographers assuming new roles. Radiologist involvement in education and training for new roles may increase their confidence and trust in radiographers to work within the limitations of their competency and training

  11. Chest radiographic manifestations of scrub typhus

    Directory of Open Access Journals (Sweden)

    KPP Abhilash

    2016-01-01

    Full Text Available Background and Rationale: Respiratory system involvement in scrub typhus is seen in 20–72% of patients. In endemic areas, good understanding and familiarity with the various radiologic findings of scrub typhus are essential in identifying pulmonary complications. Materials and Methods: Patients admitted to a tertiary care center with scrub typhus between October 2012 and September 2013 and had a chest X ray done were included in the analysis. Details and radiographic findings were noted and factors associated with abnormal X-rays were analyzed. Results: The study cohort contained 398 patients. Common presenting complaints included fever (100%, generalized myalgia (83%, headache (65%, dyspnea (54%, cough (24.3%, and altered sensorium (14%. Almost half of the patients (49.4% had normal chest radiographs. Common radiological pulmonary abnormalities included pleural effusion (14.6%, acute respiratory distress syndrome (14%, airspace opacity (10.5%, reticulonodular opacities (10.3%, peribronchial thickening (5.8%, and pulmonary edema (2%. Cardiomegaly was noted in 3.5% of patients. Breathlessness, presence of an eschar, platelet counts of 2 mg/dL had the highest odds of having an abnormal chest radiograph. Patients with an abnormal chest X-ray had a higher requirement of noninvasive ventilation (odds ratio [OR]: 13.98; 95% confidence interval CI: 5.89–33.16, invasive ventilation (OR: 18.07; 95% CI: 6.42–50.88, inotropes (OR: 8.76; 95% CI: 4.35–17.62, higher involvement of other organ systems, longer duration of hospital stay (3.18 ± 3 vs. 7.27 ± 5.58 days; P< 0.001, and higher mortality (OR: 4.63; 95% CI: 1.54–13.85. Conclusion: Almost half of the patients with scrub typhus have abnormal chest radiographs. Chest radiography should be included as part of basic evaluation at presentation in patients with scrub typhus, especially in those with breathlessness, eschar, jaundice, and severe thrombocytopenia.

  12. Radiographical analysis concernig the etiology of degenerative spondylolisthesis of the lumbar spine

    International Nuclear Information System (INIS)

    Ihara, Koichiro

    1989-01-01

    The purpose of this article is to evaluate radiographically degenerative spondylolisthesis of the lumbar spine, with the main focus on the configuration of posterior elements. A comparative study between 49 cases of degenerative spondylolisthesis and 99 cases of other lumbar disorders was performed, using 13 radiographical parameters. The results clearly indicate the posterior elements of degenerative spondylolisthesis shifted horizontally and sagittally to allow slipping. This was due to the weak bony hook mechanism. Furthermore, almost all facet joints were morphologically classified as sagittal or intermediate type. Another meaningful difference was the alignment of the lumbar spine which showed an increase in both lordosis and lumbosacral angle. On the other hand, the level of Jacoby's line was almost the same in both groups. These characteristic configurations could be the cause of listhesis, although further study should be carried out to elucidate whether they are present at the non-listhetic stage. (author)

  13. Radiographical analysis concernig the etiology of degenerative spondylolisthesis of the lumbar spine

    Energy Technology Data Exchange (ETDEWEB)

    Ihara, Koichiro [Yamaguchi Univ., Ube (Japan). School of Medicine

    1989-12-01

    The purpose of this article is to evaluate radiographically degenerative spondylolisthesis of the lumbar spine, with the main focus on the configuration of posterior elements. A comparative study between 49 cases of degenerative spondylolisthesis and 99 cases of other lumbar disorders was performed, using 13 radiographical parameters. The results clearly indicate the posterior elements of degenerative spondylolisthesis shifted horizontally and sagittally to allow slipping. This was due to the weak bony hook mechanism. Furthermore, almost all facet joints were morphologically classified as sagittal or intermediate type. Another meaningful difference was the alignment of the lumbar spine which showed an increase in both lordosis and lumbosacral angle. On the other hand, the level of Jacoby's line was almost the same in both groups. These characteristic configurations could be the cause of listhesis, although further study should be carried out to elucidate whether they are present at the non-listhetic stage. (author).

  14. Chest radiographic findings in acute paraquat poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Na, Gyeong Gyun; Lee, Mi Sook; Kim, Hee Jun; Sun, In O [Presbyterian Medical Center, Jeonju (Korea, Republic of)

    2016-01-15

    To describe the chest radiographic findings of acute paraquat poisoning. 691 patients visited the emergency department of our hospital between January 2006 and October 2012 for paraquat poisoning. Of these 691, we identified 56 patients whose initial chest radiographs were normal but who developed radiographic abnormalities within one week. We evaluated their radiographic findings and the differences in imaging features based on mortality. The most common finding was diffuse consolidation (29/56, 52%), followed by consolidation with linear and nodular opacities (18/56, 32%), and combined consolidation and pneumomediastinum (7/56, 13%). Pleural effusion was noted in 17 patients (30%). The two survivors (4%) showed peripheral consolidations, while the 54 patients (96%) who died demonstrated bilateral (42/54, 78%) or unilateral (12/54, 22%) diffuse consolidations. Rapidly progressing diffuse pulmonary consolidation was observed within one week on follow-up radiographs after paraquat ingestion in the deceased, but the survivors demonstrated peripheral consolidation.

  15. Chest radiographic findings of scrub typhus: an analysis of 160 cases occurred in Ulsan area

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ok Hwa; Oh, Dong Heon; Kim, Ki Sung; Woo, Je Ho; Kwon, Jung Hyeok [Dong Kang General Hospital, Ulsan (Korea, Republic of)

    1993-03-15

    Scrub typhus (Tsutsugamushi disease) is an acute febrile systemic illness caused by Rickettsia Tsutsugamushi that is transmitted to humans by the bite of larval-stage trombiculid mites (chiggers). The authors analyzed chest radiographic findings of scrub typhus in 160 patients in Ulsan area. One hundred and eight (67.5%) of 160 patients showed abnormal findings which included lung lesions in 108 patients (67.5%), cardiomegaly in 37 patients (23.1%), lymphadenopathy in 25 patients (15.6%) and pleural effusion in 11 patients (6.9%). Among the lung lesions, interstitial patterns were seen in 107 patients (66.9%), mostly fine or medium reticulonodular, and air-space patterns in 14 patients (8.8%) and combined interstitial and air-space patterns in 13 patients (8.1%). Sixty-four patients (40%) had combined chest radiographic findings. The typical chest radiographic findings of scrub typhus would be helpful in evaluation of the causes of acute febrile illness that occur during late fall in the endemic area.

  16. Chest radiographic findings of scrub typhus: an analysis of 160 cases occurred in Ulsan area

    International Nuclear Information System (INIS)

    Kim, Ok Hwa; Oh, Dong Heon; Kim, Ki Sung; Woo, Je Ho; Kwon, Jung Hyeok

    1993-01-01

    Scrub typhus (Tsutsugamushi disease) is an acute febrile systemic illness caused by Rickettsia Tsutsugamushi that is transmitted to humans by the bite of larval-stage trombiculid mites (chiggers). The authors analyzed chest radiographic findings of scrub typhus in 160 patients in Ulsan area. One hundred and eight (67.5%) of 160 patients showed abnormal findings which included lung lesions in 108 patients (67.5%), cardiomegaly in 37 patients (23.1%), lymphadenopathy in 25 patients (15.6%) and pleural effusion in 11 patients (6.9%). Among the lung lesions, interstitial patterns were seen in 107 patients (66.9%), mostly fine or medium reticulonodular, and air-space patterns in 14 patients (8.8%) and combined interstitial and air-space patterns in 13 patients (8.1%). Sixty-four patients (40%) had combined chest radiographic findings. The typical chest radiographic findings of scrub typhus would be helpful in evaluation of the causes of acute febrile illness that occur during late fall in the endemic area

  17. Radiographic findings of femoroacetabular impingement in National Football League Combine athletes undergoing radiographs for previous hip or groin pain.

    Science.gov (United States)

    Nepple, Jeffrey J; Brophy, Robert H; Matava, Matthew J; Wright, Rick W; Clohisy, John C

    2012-10-01

    The purpose of this study was to investigate the prevalence of radiographic findings of femoroacetabular impingement (FAI) in elite football players with a history of hip pain or groin injury who underwent radiographs. We performed a retrospective review of athletes undergoing hip radiography at the National Football League Combine from 2007 to 2009. Radiographs were obtained in athletes with a history of hip pain or injury. Anteroposterior pelvis and frog-lateral radiographs were obtained in 123 hips (107 players) that met our inclusion criteria. Radiographic indicators of cam-type FAI (alpha angle, head-neck offset ratio) and pincer-type FAI (acetabular retroversion, center-edge angle, acetabular inclination) were recorded. Findings were correlated with clinical factors (previous groin/hip pain, position, race, and body mass index). The most common previous injuries included groin strain (n = 57) and sports hernia/abdominal strain (n = 21). Markers of cam- and/or pincer-type FAI were present in 94.3% of hips (116 of 123). Radiographic evidence of combined cam- and pincer-type FAI was the most common (61.8%, 76 hips), whereas isolated cam-type FAI (9.8%, 12 hips) and pincer-type FAI (22.8%, 28 hips) were less common. The most common deformities included acetabular retroversion (71.5%) and an abnormal alpha angle (61.8%). A body mass index greater than 35 was associated with the presence of global overcoverage (46.2% v 17.3%, P = .025). Radiographic indicators of FAI are very common among athletes evaluated at the National Football League Scouting Combine subjected to radiographic examination for the clinical suspicion of hip disease. Elite football athletes with significant or recurrent pain about the hip should be evaluated clinically and radiographically for FAI, because pain from FAI may be falsely attributed to or may be present in addition to other disorders. Level IV, therapeutic case series. Copyright © 2012 Arthroscopy Association of North America

  18. The use and abuse of radiographic grids

    International Nuclear Information System (INIS)

    Brough, P.D.

    1981-01-01

    It is generally accepted that scattered radiation degrades the quality of the radiographic image. When this problem occurs, a radiographic grid may be applied which necessitates an increase in exposure. Investigations are reported in the following areas: reasons for the introduction of a radiographic grid; the ratio between kilovoltage and grid ratio; techniques resulting in higher contrast and resolution at low patient dose and the abuse of grids

  19. 21 CFR 892.1970 - Radiographic ECG/respirator synchronizer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic ECG/respirator synchronizer. 892.1970... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1970 Radiographic ECG/respirator synchronizer. (a) Identification. A radiographic ECG/respirator synchronizer is a device intended to be used to...

  20. Complications from radiographer-performed double contrast barium enemas

    Energy Technology Data Exchange (ETDEWEB)

    Vora, P.; Chapman, A. E-mail: anthony.chapman@leedsth.nhs.uk

    2004-04-01

    AIM: To determine the types and rates of complications encountered by radiographers when performing double contrast barium enemas (DCBE). MATERIALS AND METHODS: Seven hundred and forty-one questionnaires were posted to radiographers who had in the last 5 years attended one of the biannual barium enema training courses. RESULTS: Of 741 questionnaires posted 407 (54.9%) were returned completed. Approximately 348,000 barium enema examinations had been performed. Fifty-nine radiographers reported 89 complications, including 13 intra-peritoneal and 11 extra-peritoneal perforations. There were five deaths (mortality 1 in 70,000). Deaths resulted from two of 24 (10%) perforations, two of 45 (5%) cardiac events and one cerebrovascular accident that occurred during an examination. CONCLUSIONS: Radiographers have been regularly performing DCBEs for almost a decade. The mortality for radiographer-performed DCBE is similar to that previously reported for radiologists, although a slightly higher rate of perforation is noted and so this is an area where radiographer training should be targeted.

  1. Complications from radiographer-performed double contrast barium enemas

    International Nuclear Information System (INIS)

    Vora, P.; Chapman, A.

    2004-01-01

    AIM: To determine the types and rates of complications encountered by radiographers when performing double contrast barium enemas (DCBE). MATERIALS AND METHODS: Seven hundred and forty-one questionnaires were posted to radiographers who had in the last 5 years attended one of the biannual barium enema training courses. RESULTS: Of 741 questionnaires posted 407 (54.9%) were returned completed. Approximately 348,000 barium enema examinations had been performed. Fifty-nine radiographers reported 89 complications, including 13 intra-peritoneal and 11 extra-peritoneal perforations. There were five deaths (mortality 1 in 70,000). Deaths resulted from two of 24 (10%) perforations, two of 45 (5%) cardiac events and one cerebrovascular accident that occurred during an examination. CONCLUSIONS: Radiographers have been regularly performing DCBEs for almost a decade. The mortality for radiographer-performed DCBE is similar to that previously reported for radiologists, although a slightly higher rate of perforation is noted and so this is an area where radiographer training should be targeted

  2. ‘On their side’: Focus group findings regarding the role of MRI radiographers and patient care

    International Nuclear Information System (INIS)

    Munn, Zachary; Jordan, Zoe; Pearson, Alan; Murphy, Frederick; Pilkington, Diana

    2014-01-01

    Introduction: Radiographers have been described as caring and concerned healthcare professionals, who are attentive to the needs of their patients. However, this may not always be the case, and patient care may be overlooked at times. Methods: A qualitative descriptive study using a focus group was conducted with radiographers to determine their views on patient care. The focus group included 7 MRI radiographers of varying levels of experience. The data was analysed following a process of thematic analysis. Results: 7 themes emerged from analysis of the data. These were; a trade-off, a wide range of patients with a wide range of issues, from one extreme to the other, it's not that bad, getting the patient scanned, room for improvement, and on their side. Conclusion: The radiographers considered themselves on the patient's side, with the main objective to get the patient scanned, in some way, to aid in their diagnosis and treatment

  3. Stress fractures in the lower extremity

    International Nuclear Information System (INIS)

    Berger, Ferco H.; Jonge, Milko C. de; Maas, Mario

    2007-01-01

    Stress fractures are fatigue injuries of bone usually caused by changes in training regimen in the population of military recruits and both professional and recreational athletes. Raised levels of sporting activity in today's population and refined imaging technologies have caused a rise in reported incidence of stress fractures in the past decades, now making up more than 10% of cases in a typical sports medicine practice. Background information (including etiology, epidemiology, clinical presentation and treatment and prevention) as well as state of the art imaging of stress fractures will be discussed to increase awareness amongst radiologists, providing the tools to play an important role in diagnosis and prognosis of stress fractures. Specific fracture sites in the lower extremity will be addressed, covering the far majority of stress fracture incidence. Proper communication between treating physician, physical therapist and radiologist is needed to obtain a high index of suspicion for this easily overlooked entity. Radiographs are not reliable for detection of stress fractures and radiologist should not falsely be comforted by them, which could result in delayed diagnosis and possibly permanent consequences for the patient. Although radiographs are mandatory to rule out differentials, they should be followed through when negative, preferably by magnetic resonance imaging (MRI), as this technique has proven to be superior to bone scintigraphy. CT can be beneficial in a limited number of patients, but should not be used routinely

  4. Who are they? Identities in the Norwegian radiographer profession as presented in the Norwegian printed press

    International Nuclear Information System (INIS)

    Stalsberg, R.; Thingnes, E.R.

    2016-01-01

    Purpose: To explore how Norwegian radiographers are portrayed in written press. Method: Textual discourse analysis, following a multiple step strategy, combining both a quantitative and a qualitative approach. 189 newspaper articles were included. The articles were registered and subject fields were inductively categorized. Each subject field was analysed regarding the field's role as an agent of influence on public perception of radiographers. Results: On average, less than one article a year concerning radiography profession is published in Norwegian newspapers. A majority are published in newspapers with small circulation figures, often reporting on resources in the local health services where radiographers are involved. Mostly radiographers are placed in the articles' background playing supporting roles, frequently mentioned in the cutline as an operator of a new medical technology. There is a heavy emphasis on the technology, leaving the specialized expertise and radiography knowledge out. This focus persist in the instances where radiographers play a main role in the texts. When patient stories are told, positive value-laden words are used to describe the radiographer and both the technical and the patient-care aspects of being a radiographer are noticeable. Conclusion: Norwegian radiographers typically appear, in glimpses, as anonymous allied health technicians in local reports on new diagnostic equipment or resource utilization. The professional qualities and decisive skills required to handle sophisticated diagnostic equipment and continuity of patient care are underestimated. A more-nuanced media coverage might give radiographers a strengthened identity as important health-care service contributors. - Highlights: • The radiography profession is an inconspicuous topic in Norwegian written press. • Written press involving radiographers highlight new equipment and medical technology. • Radiographers' professional qualities and decisive

  5. Clinical and radiographic evaluation of Portland cement added to radiopacifying agents in primary molar pulpotomies.

    Science.gov (United States)

    Lourenço Neto, N; Marques, N C T; Fernandes, A P; Hungaro Duarte, M A; Abdo, R C C; Machado, M A A M; Oliveira, T M

    2015-10-01

    This was to evaluate the clinical and radiographic outcomes of Portland cement (PC) added to radiopacifying agents in primary molar pulpotomies. Thirty primary mandibular molars of children aged between 5 and 9 years were randomly assigned to the following groups: PC; PC with iodoform (PC + CHI(3)); PC with zirconium oxide (PC + ZrO(2)) and treated by pulpotomy technique. Clinical and radiographic follow-up assessments were performed at 6, 12 and 24 months. Statistical analysis was performed by Fisher's exact test (P < 0.05). The clinical and radiographic evaluations showed 100 % success rates, and the results showed no statistically significant difference between groups. According to this study, PC added to radiopacifying agents exhibited satisfactory clinical and radiographic results in primary molar pulpotomies.

  6. Radiographic manifestations of arthritis in AIDS patients

    International Nuclear Information System (INIS)

    Rosenberg, Z.S.; Norman, A.; Solomon, G.

    1988-01-01

    The purpose of this study is to familiarize the radiologist with a newly discovered association between arthritis and acquired immunodeficiency syndrome (AIDS). The authors retrospectively reviewed the clinical and radiographic findings in 31 patients with human immunodeficiency virus (HIV) infection referred to their rheumatology clinic with musculoskeletal complaints. The patients carried a wide range of clinical diagnosis including Reiter syndrome, psoriatic arthritis, undifferentiated seronegative arthritis, isolated enthesopathies, rheumatoid arthritis and osteonecrosis. Radiographs were available in 24 of the 31 patients, and in 20 they showed radiographic features of arthritis, which included soft-tissue swelling periarticular osteoporosis, synovial effusions, sacroiliitis, periosteal reaction, joint space narrowing, marginal erosions, and osteonecrosis. Although the radiographic abnormalities were frequently mild, they were significant, given the short duration of disease in many of their patients (weeks to months) at the time radiographs were obtained. The range of radiographic findings in their series was varied and paralleled the wide range of clinical diagnoses. No findings were pathognomonic for HIV-associated arthritis. Nevertheless, HIV infection needs to be considered in any patient belonging to a recognized risk group who presents with musculoskeletal disease. This is particularly important since immunosupressive drugs used for the treatment of arthritis can be detrimental to patients with HIV infection

  7. Radiographers' preconditions for evidence-based radiography

    International Nuclear Information System (INIS)

    Ahonen, Sanna-Mari; Liikanen, Eeva

    2010-01-01

    Evidence-based practice (EBP) is essential in today's health care, but its establishment requires several preconditions from individuals and organizations (e.g. knowledge, understanding, attitudes, abilities, self-confidence, support, and resources). Previous studies suggest that radiographers do generate and use evidence in their work, but evidence-based radiography (EBR) is not yet used routinely as established practice, especially in terms of research utilization. This paper aims to describe radiographers' preconditions for EBR, and their participation in research activities. Main focus is on research utilization. Using an electronic questionnaire developed for this study, a survey was conducted: data collected from Finnish radiographers and radiotherapists (N = 438) were analysed both statistically and qualitatively. The final response rate was 39%. The results suggest radiographers' preconditions for EBR to consist of knowledge of research, significance of research activities, research-orientated way of working, and support. In addition, adequate resourcing is essential. Reading scientific journals, participation in research activities, a higher degree of education, and senior post seem to be significant promoters of EBR and research utilization. The results support the notion that EBR, and especially research utilization, are not yet well-established in Finland, and radiographers' viewpoints concerning the role and significance of research evidence and research activities still seem to vary.

  8. Radiographic evaluation of the diabetic foot

    International Nuclear Information System (INIS)

    Jacobs, A.M.

    1989-01-01

    Radiographic evaluation of the foot in the patient with diabetes mellitus is discussed in this paper. According to the author, it can only be of value when the soft tissue and bony and joint pathologic conditions, which occur more frequently in the diabetic patient are also considered and understood. Although not pathognomic for diabetes mellitus, neuroarthopathy, osteomyelitis, soft tissue infection, and some rheumatic disorders are present with greater frequency in diabetic populations than in non-diabetic populations. Frequently, edema, erythema, hyperthermia, and tenderness are present as nonspecific clinical findings, in which case radiographic evaluation is called upon to define the specific etiology of a particular patient's pathology. Unfortunately, many radiographic, computerized tomographic, and radionuclide studies demonstrate less than optimal positive and negative predictive values unless interpreted in view of clinical history and examination and integrated with the results of other laboratory data. Radiographic evaluation of the diabetic foot may be utilized to establish the presence of disease, the extent of pedal involvement, and the response to therapy. The establishment of the nature of disease processes from radiographic findings alone, however, may be problematic. The diagnosis of osteomyelitis, for example, rests on the recovery of the offending microorganisms from bone aspiration or culture

  9. Spartan Release Engagement Mechanism (REM) stress and fracture analysis

    Science.gov (United States)

    Marlowe, D. S.; West, E. J.

    1984-01-01

    The revised stress and fracture analysis of the Spartan REM hardware for current load conditions and mass properties is presented. The stress analysis was performed using a NASTRAN math model of the Spartan REM adapter, base, and payload. Appendix A contains the material properties, loads, and stress analysis of the hardware. The computer output and model description are in Appendix B. Factors of safety used in the stress analysis were 1.4 on tested items and 2.0 on all other items. Fracture analysis of the items considered fracture critical was accomplished using the MSFC Crack Growth Analysis code. Loads and stresses were obtaind from the stress analysis. The fracture analysis notes are located in Appendix A and the computer output in Appendix B. All items analyzed met design and fracture criteria.

  10. Radiographic features of periapical cysts and granulomas

    OpenAIRE

    Zain, R. B.; Roswati, N.; Ismail, K.

    1989-01-01

    Many studies have been reported on radiographic lesion sizes of periapical lesions. However no studies have been reported on prevalences of subjective radiographic features in these lesions except for the early assumption that a periapical cyst usually exhibit a radiopaque cortex. This study is conducted to evaluate the prevalences of several subjective radiographic features of periapical cysts and granulomas in the hope to identify features that maybe suggestive of either diagnosis. The resu...

  11. Comparison of film/screen and PCR digital lateral cervical spine radiographs

    International Nuclear Information System (INIS)

    Silver, D.I.; Kreipke, D.L.; Tarver, R.; Braunstein, E.M.

    1988-01-01

    The authors compared film/screen and Phillips computed radiography (PCR) radiographs of the cervical spine. In 109 patients. fiilm/screen and digital radiographs were compared for adequate visualization (readability) of bone, soft tissue, and trachea. The lowest cervical vertebra seen was noted in each case. The radiographs were interpreted by four radiologists, and both interobserver and intraobserver consistency were measured. Of the PCR radiographs, 97% were readable with a viewbox alone. Of the film/screen radiographs, 9% were readable with a viewbox. With a hotlight, 83% of the film/screen radiographs became readable. Bone, soft tissue, and trachea were better seen on PCR radiographs than on film/screen radiographs (P<.001). There was less interobserver variation on digital radiographs. Readability of cervical spine radiographs was significantly improved with PCR

  12. Radiographic identification of the equine ventral conchal bulla.

    Science.gov (United States)

    Finnegan, C M; Townsend, N B; Barnett, T P; Barakzai, S Z

    Involvement of the ventral conchal sinus (VCS) is an important diagnostic and prognostic feature in cases of the equine sinus disease. The authors aimed to ascertain if the caudo-dorsal extension of the VCS, the ventral conchal bulla (VCB) is identifiable on plain radiographs of cadaver skulls without sinus disease. Bilateral frontonasal sinus flaps were made in 10 equine cadaver skulls. Plain lateral, lateral oblique and dorso-ventral radiographs were then obtained followed by the same views taken with stainless steel wire outlining the caudal border of the VCB. Plain radiographs were randomised and blindly evaluated by two observers who marked where they believed the VCB to be positioned. This was then correlated with the true position of the VCB using radiographs with wires in place. The ease of identification of the VCB was classified as 'easy' or 'difficult'. The VCB was correctly identified in 70 per cent of lateral radiographs, but only 45 per cent of lateral oblique radiographs and 17 per cent of dorso-ventral radiographs. If a clinician was confident that he or she could identify the VCB, they were usually correct. Conversely if the clinician judged VCB identification as 'difficult', they usually identified it incorrectly. In the authors' clinical experience, the VCB of horses with sinusitis involving this compartment is more radiologically evident than in clinically normal horses. Knowledge of the normal radiographic anatomy of this structure should aid clinicians in identifying horses with sinusitis affecting the VCS.

  13. Development of a fully automated adaptive unsharp masking technique in digital chest radiograph

    International Nuclear Information System (INIS)

    Abe, Katsumi; Katsuragawa, Shigehiko; Sasaki, Yasuo

    1991-01-01

    We are developing a fully automated adaptive unsharp masking technique with various parameters depending on regional image features of a digital chest radiograph. A chest radiograph includes various regions such as lung fields, retrocardiac area and spine in which their texture patterns and optical densities are extremely different. Therefore, it is necessary to enhance image contrast of each region by each optimum parameter. First, we investigated optimum weighting factors and mask sizes of unsharp masking technique in a digital chest radiograph. Then, a chest radiograph is automatically divided into three segments, one for the lung field, one for the retrocardiac area, and one for the spine, by using histogram analysis of pixel values. Finally, high frequency components of the lung field and retrocardiac area are selectively enhanced with a small mask size and mild weighting factors which are previously determined as optimum parameters. In addition, low frequency components of the spine are enhanced with a large mask size and adequate weighting factors. This processed image shows excellent depiction of the lung field, retrocardiac area and spine simultaneously with optimum contrast. Our image processing technique may be useful for diagnosis of chest radiographs. (author)

  14. Contribution to identification of factors causing radiographic image unsharpness

    International Nuclear Information System (INIS)

    Branzan, C.; Popescu, A.; Radu, R.

    1995-01-01

    Radiographic image quality is crucial for the ability of the radiographic method to give us a maximum information about the macroscopic structure of materials and pieces, investigated by penetrating radiation. Radiographic image quality depends on several factors. A high quality image is able to show small and typical defects. One of the most important factor affecting radiographic image is unsharpness. The total effective unsharpness of the film must be some function of several factors and their contribution is taken into account by summing up different kinds of unsharpness: geometric unsharpness, internal unsharpness, screen unsharpness, and accidental unsharpness. This work analyses the weight of the radiographic image unsharpness and the possibilities for determining its influence on the quality of the radiographic image. (author)

  15. Correlation between static radiographic measurements and intersegmental angular measurements during gait using a multisegment foot model.

    Science.gov (United States)

    Lee, Dong Yeon; Seo, Sang Gyo; Kim, Eo Jin; Kim, Sung Ju; Lee, Kyoung Min; Farber, Daniel C; Chung, Chin Youb; Choi, In Ho

    2015-01-01

    Radiographic examination is a widely used evaluation method in the orthopedic clinic. However, conventional radiography alone does not reflect the dynamic changes between foot and ankle segments during gait. Multiple 3-dimensional multisegment foot models (3D MFMs) have been introduced to evaluate intersegmental motion of the foot. In this study, we evaluated the correlation between static radiographic indices and intersegmental foot motion indices. One hundred twenty-five females were tested. Static radiographs of full-leg and anteroposterior (AP) and lateral foot views were performed. For hindfoot evaluation, we measured the AP tibiotalar angle (TiTA), talar tilt (TT), calcaneal pitch, lateral tibiocalcaneal angle, and lateral talcocalcaneal angle. For the midfoot segment, naviculocuboid overlap and talonavicular coverage angle were calculated. AP and lateral talo-first metatarsal angles and metatarsal stacking angle (MSA) were measured to assess the forefoot. Hallux valgus angle (HVA) and hallux interphalangeal angle were measured. In gait analysis by 3D MFM, intersegmental angle (ISA) measurements of each segment (hallux, forefoot, hindfoot, arch) were recorded. ISAs at midstance phase were most highly correlated with radiography. Significant correlations were observed between ISA measurements using MFM and static radiographic measurements in the same segment. In the hindfoot, coronal plane ISA was correlated with AP TiTA (P foot motion indices at midstance phase during gait measured by 3D MFM gait analysis were correlated with the conventional radiographic indices. The observed correlation between MFM measurements at midstance phase during gait and static radiographic measurements supports the fundamental basis for the use of MFM in analysis of dynamic motion of foot segment during gait. © The Author(s) 2014.

  16. Nuclear class 1 piping stress analysis

    International Nuclear Information System (INIS)

    Lucas, J.C.R.; Maneschy, J.E.; Mariano, L.A.; Tamura, M.

    1981-01-01

    A nuclear class 1 piping stress analysis, according to the ASME code, is presented. The TRHEAT computer code has been used to determine the piping wall thermal gradient. The Nupipe computer code was employed for the piping stress analysis. Computer results were compared with the allowable criteria from the ASME code. (Author) [pt

  17. Presentation and analysis of radiographic data in clinical trials and observational studies

    NARCIS (Netherlands)

    Landewé, R.; van der Heijde, D.

    2005-01-01

    Despite the advent of sophisticated imaging systems, plain radiography continues to be a valuable outcome variable in clinical trials of inflammatory disorders for a number of reasons. This paper discusses the pros and cons of the different ways in which radiographic data in trials is presented; the

  18. Factors associated with recurrent fifth metatarsal stress fracture.

    Science.gov (United States)

    Lee, Kyung-tai; Park, Young-uk; Jegal, Hyuk; Kim, Ki-chun; Young, Ki-won; Kim, Jin-su

    2013-12-01

    Many surgeons agree that fifth metatarsal stress fractures have a tendency toward delayed union, nonunion, and possibly refracture. Difficulty healing seems to be correlated with fracture classification. However, refracture sometimes occurs after low-grade fracture, even long after apparent resolution. The records of 168 consecutive cases of fifth metatarsal stress fracture (163 patients) treated by modified tension band wiring from March 2002 to June 2011 were evaluated retrospectively. Mean length of follow-up was 23.6 months (range, 10-112 months). Forty-nine cases classified as Torg III were bone grafted initially also. All enrolled patients were elite athletes. Eleven patients experienced nonunion and 18 refracture. The 11 nonunion cases were bone grafted. The 157 patients (excluding nonunion cases) were allocated to either a refracture group or a union group. Clinical features, such as age, weight, fracture classification, time to union, and reinjury history, were compared. Radiological parameters representing cavus deformity and fifth metatarsal head protrusion were compared to evaluate the influence of structural abnormalities. Mean group weights were significantly different (P = .041), but mean ages (P = .879), fracture grades (P = .216, P = .962), and time from surgery to rehabilitation (P = .539) were similar. No significant intergroup differences were found for talocalcaneal (TC) angle (P = .470), calcaneal pitch (CP) angle (P = .847), or talo-first metatarsal (T-MT1) angle (P = .407) on lateral radiographs; for fifth metatarsal lateral deviation (MT5-LD) angle (P = .623) on anteroposterior (AP) radiographs; or for MT5-LD angle (P = .065) on the 30-degree medial oblique radiographs. However, the mean fourth-fifth intermetatarsal (IMA4-5) angle on AP radiographs was significantly greater in the refracture group, and for Torg II cases, mean weight (P = .042), IMA4-5 angle on AP radiographs (P = .014), and MT5-LD angle (P = .043) on 30-degree medial

  19. Radiographical analysis concernig the etiology of degenerative spondylolisthesis of the lumbar spine

    Energy Technology Data Exchange (ETDEWEB)

    Ihara, Koichiro (Yamaguchi Univ., Ube (Japan). School of Medicine)

    1989-12-01

    The purpose of this article is to evaluate radiographically degenerative spondylolisthesis of the lumbar spine, with the main focus on the configuration of posterior elements. A comparative study between 49 cases of degenerative spondylolisthesis and 99 cases of other lumbar disorders was performed, using 13 radiographical parameters. The results clearly indicate the posterior elements of degenerative spondylolisthesis shifted horizontally and sagittally to allow slipping. This was due to the weak bony hook mechanism. Furthermore, almost all facet joints were morphologically classified as sagittal or intermediate type. Another meaningful difference was the alignment of the lumbar spine which showed an increase in both lordosis and lumbosacral angle. On the other hand, the level of Jacoby's line was almost the same in both groups. These characteristic configurations could be the cause of listhesis, although further study should be carried out to elucidate whether they are present at the non-listhetic stage. (author).

  20. Image quality in digital radiographic systems

    Directory of Open Access Journals (Sweden)

    Almeida Solange Maria de

    2003-01-01

    Full Text Available The aim of the present study was to evaluate the image quality of four direct digital radiographic systems. Radiographs were made of the maxillary central incisor and mandibular left molar regions of a dry skull, and an aluminum step-wedge. The X-ray generator operated at 10 mA, 60 and 70 kVp, and images were acquired with 3, 5, 8, 12, 24 and 48 exposure pulses. Six well-trained observers classified the images by means of scores from 1 to 3. Collected data were submitted to nonparametric statistical analysis using Fisher's exact test. Statistical analysis showed significant differences (p<0.01 in image quality with the four systems. Based on the results, it was possible to conclude that: 1 all of the digital systems presented good performance in producing acceptable images for diagnosis, if the exposures of the step-wedge and the maxillary central incisor region were made at 5 pulses, as well as at 8 pulses for the mandibular left molar region, selecting 60 or 70kVp; 2 higher percentages of acceptable images were obtained with the administration of lower radiation doses in CCD-sensors (charge-coupled device; 3 the Storage Phosphor systems produced acceptable images at a large range of exposure settings, that included low, intermediate and high radiation doses.

  1. Diagnostic ability of the periapical radiographs and digital image in the detection of the artificial proximal caries

    International Nuclear Information System (INIS)

    Heo, Min Suk; You, Dong Soo

    1994-01-01

    Recently, the digital image was introduced into radiological image. The digital image has the power of contrast enhancement, histogram control, and other digitally enhancement. At the point of the resolution, periapical radiograph is superior to the digital image, but enhanced digital procedure improves the diagnostic ability of the digital image. The purpose of this study was to evaluate the diagnostic ability of artificial proximal caries in conventional radiographs, digital radiographs and enhanced digital radiographs (histogram specification). ROC (Receiver Operating Characteristic) analysis and paired t-test were used for the evaluation of detectability, and following results were acquired: 1. The mean ROC area of conventional radiographs was 0.9274. 2. The mean ROC area of unenhanced digital image was 0.9168. 3. The mean ROC area of enhanced digital image was 0.9339. 4. The diagnostic ability of three imaging methods was not significant difference (p>0.05). So, the digital images had similar diagnostic ability of artificial proximal caries to conventional radiographs. If properly enhanced digital image, it may be superior to conventional radiographs.

  2. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD)

    Energy Technology Data Exchange (ETDEWEB)

    Nitschke, Ashley [University of Colorado School of Medicine, University of Colorado Denver, Division of Musculoskeletal Radiology, Department of Radiology, Aurora, CO (United States); Lambert, Jeffery R. [University of Colorado, Department of Biostatistics and Informatics, Colorado School of Public Health, Aurora, CO (United States); Glueck, Deborah H. [University of Colorado, Department of Biostatistics and Informatics, Colorado School of Public Health, Aurora, CO (United States); University of Colorado School of Medicine, University of Colorado Denver, Department of Radiology, Aurora, CO (United States); Jesse, Mary Kristen; Strickland, Colin [University of Colorado School of Medicine, University of Colorado Denver, Division of Musculoskeletal Radiology, Department of Radiology and Orthopaedics, Aurora, CO (United States); Mei-Dan, Omer [University of Colorado School of Medicine, University of Colorado Denver, Division of Sports Medicine and Hip Preservation, Department of Orthopaedics, Aurora, CO (United States); Petersen, Brian [University of Colorado School of Medicine, University of Colorado Denver, Division of Musculoskeletal Radiology, Department of Radiology and Orthopaedics, Aurora, CO (United States); Inland Imaging, Division of Musculoskeletal Radiology, Spokane, WA (United States)

    2015-11-15

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p < 0.001) or TAD (p < 0.001). The diagnostic accuracies of p/a ratio and TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain. (orig.)

  3. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD)

    International Nuclear Information System (INIS)

    Nitschke, Ashley; Lambert, Jeffery R.; Glueck, Deborah H.; Jesse, Mary Kristen; Strickland, Colin; Mei-Dan, Omer; Petersen, Brian

    2015-01-01

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p < 0.001) or TAD (p < 0.001). The diagnostic accuracies of p/a ratio and TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain. (orig.)

  4. Unicystic Jaw Lesions: A Radiographic Guideline

    Directory of Open Access Journals (Sweden)

    Giju George

    2010-01-01

    Full Text Available The unilocular radiolucencies remain the topic of much interest for the clinicians and histhopathologists for decades. Adequate use of diagnostic aids and careful observation will clinically help the dentist to arrive at a proper diagnosis and renders quality treatment to patients. Despite of the development of various cross-sectional imaging modalities, the radiograph still remains as the first and most important investigation. Jaw bone lesions, especially unilocular ones, are difficult to diagnose radiologically because of their similar radiographic appearance. It is, thus, very important for the clinician to have a sound knowledge of various radiographic features of the tooth and its supporting structures.

  5. Influence of the intergonial distance on image distortion in panoramic radiographs.

    Science.gov (United States)

    Ladeira, D B S; Cruz, A D; Almeida, S M; Bóscolo, F N

    2012-07-01

    The aim of this study was to evaluate the influence of the intergonial distance during the formation of panoramic radiographic images by means of horizontal and vertical measurements. 30 macerated mandibles were categorized into 3 different groups (n = 10) according to their intergonial distances as follows: G1, mean distance 8.2 cm, G2, mean distance 9.0 cm and G3, mean distance 9.6 cm. Three metal spheres 0.198 cm in diameter and placed at an incline using an isosceles triangle were separately placed over the internal and external surfaces of the mandibles before radiographic exposure for the purpose of taking the horizontal and vertical measurements. The occlusal planes of the mandibles were horizontally placed on the chin rest of the panoramic machine Orthopantomograph® OP 100 (Instrumentarium Imaging, Tuusula, Finland) and were then radiographed. In the panoramic radiographs, an expert radiologist measured the distances between the metal spheres in the horizontal and vertical directions using a digital caliper. The data were tabled and statistically analysed by Student's t-test and analysis of variance with Tukey post-test (α = 0.05). In all three groups magnification of the distances between spheres was observed when compared with the real distance in both horizontal and vertical measurements (p 0.05). Differences between horizontal and vertical measurements were observed in different regions in all evaluated groups (p image formation in the panoramic radiograph.

  6. Can Australian radiographers assess screening mammograms accurately? First stage results from a four year prospective study

    International Nuclear Information System (INIS)

    Moran, S.; Warren-Forward, H.

    2016-01-01

    Introduction: Globally, the role of the radiographer is changing; some countries have developed advanced roles with specific scopes of practice. Other countries, like Australia, are in the process of this change. The aim of this research is to assess the diagnostic outcomes reported by the radiographers and compare them to those reported by current screen readers. Method: Six experienced radiographers were invited to participate in a prospective study conducted between 2010 and 2011. They were required to read 2000 mammograms each. Their results were compared with those of the radiologists. Statistical analysis of the results included overall cancer detection rates, recall rates, levels of agreement, kappa, sensitivity, specificity, accuracy, positive predictive value and negative predictive value. Results: A total of 9348 women were included in the study. The percentage of cancers detected by the radiographers ranged from 53% to 100% of the cancers detected by the radiologists. Radiologist recall rate ranged between 3.4% and 5.5% and the radiographers' range was 2.9%–9.8%. Level of agreement of the radiographers with the radiologists ranged from 90 to 96%. Conclusion: The potential for accuracy in screen reading by Australian radiographers is supported by the results of this study. Implementation of formal training is likely to result in an increase in the diagnostic accuracy of radiographers. - Highlights: • Radiographers prospectively read 2000 screening mammograms each. • These results support potential for accuracy in screen reading by radiographers. • Will advanced practice be introduced within BreastScreen Australia?.

  7. Adult Sail Sign: Radiographic and Computed Tomographic Features

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yu-Jin; Han, Daehee; Koh, Young Hwan; Zo, Joo Hee; Kim, Sang-Hyun; Kim, Deog Kyeom; Lee, Jeong Sang; Moon, Hyeon Jong; Kim, Jong Seung; Chun, Eun Ju; Youn, Byung Jae; Lee, Chang Hyun; Kim, Sam Soo (Dept. of Radiology, Cheil General Hospital, Kwandong Univ. College of Medicine, Seoul (KR))

    2008-02-15

    Background: The sail sign is a well-known radiographic feature of the pediatric chest. This sign can be observed in an adult population as well, but for a different reason. Purpose: To investigate the sail sign appearing in adult chest radiography. Material and Methods: Based on two anecdotal adult cases in which frontal chest radiographs showed the sail sign, we prospectively screened radiographs of 10,238 patients to determine the incidence of the sail sign found in adults in their 40s or older. The cause of the sail sign was assessed using computed tomography (CT). Results: The sail sign was revealed in 10 (seven males, three females; median age 60.6 years) of 10,238 patients. Of these 10 patients with a sail sign on frontal radiographs, eight underwent CT. The frontal radiographs of these 10 patients showed a concave superior margin toward the lung in nine patients, a concave inferior margin in five, and a double-lined inferior margin in three. Lateral radiographs disclosed a focal opacity over the minor fissure in five of six patients, which was either fuzzy (n = 4) or sharp (n = 1) in its upper margin, and was sometimes double lined in the inferior margin (n = 3). CT revealed the anterior mediastinal fat to be the cause of the radiographic sail sign, which stretched laterally from the mediastinum to insinuate into the minor fissure. Conclusion: The incidence of sail sign on adult chest radiographs is about 0.1%. The sign is specific enough to eliminate the need for more sophisticated imaging

  8. Adult Sail Sign: Radiographic and Computed Tomographic Features

    International Nuclear Information System (INIS)

    Lee, Yu-Jin; Han, Daehee; Koh, Young Hwan; Zo, Joo Hee; Kim, Sang-Hyun; Kim, Deog Kyeom; Lee, Jeong Sang; Moon, Hyeon Jong; Kim, Jong Seung; Chun, Eun Ju; Y oun, Byung Jae; Lee, Chang Hyun; Kim, Sam Soo

    2008-01-01

    Background: The sail sign is a well-known radiographic feature of the pediatric chest. This sign can be observed in an adult population as well, but for a different reason. Purpose: To investigate the sail sign appearing in adult chest radiography. Material and Methods: Based on two anecdotal adult cases in which frontal chest radiographs showed the sail sign, we prospectively screened radiographs of 10,238 patients to determine the incidence of the sail sign found in adults in their 40s or older. The cause of the sail sign was assessed using computed tomography (CT). Results: The sail sign was revealed in 10 (seven males, three females; median age 60.6 years) of 10,238 patients. Of these 10 patients with a sail sign on frontal radiographs, eight underwent CT. The frontal radiographs of these 10 patients showed a concave superior margin toward the lung in nine patients, a concave inferior margin in five, and a double-lined inferior margin in three. Lateral radiographs disclosed a focal opacity over the minor fissure in five of six patients, which was either fuzzy (n = 4) or sharp (n = 1) in its upper margin, and was sometimes double lined in the inferior margin (n = 3). CT revealed the anterior mediastinal fat to be the cause of the radiographic sail sign, which stretched laterally from the mediastinum to insinuate into the minor fissure. Conclusion: The incidence of sail sign on adult chest radiographs is about 0.1%. The sign is specific enough to eliminate the need for more sophisticated imaging

  9. Adult sail sign: radiographic and computed tomographic features.

    Science.gov (United States)

    Lee, Yu-Jin; Han, Daehee; Koh, Young Hwan; Zo, Joo Hee; Kim, Sang-Hyun; Kim, Deog Kyeom; Lee, Jeong Sang; Moon, Hyeon Jong; Kim, Jong Seung; Chun, Eun Ju; Youn, Byung Jae; Lee, Chang Hyun; Kim, Sam Soo

    2008-02-01

    The sail sign is a well-known radiographic feature of the pediatric chest. This sign can be observed in an adult population as well, but for a different reason. To investigate the sail sign appearing in adult chest radiography. Based on two anecdotal adult cases in which frontal chest radiographs showed the sail sign, we prospectively screened radiographs of 10,238 patients to determine the incidence of the sail sign found in adults in their 40s or older. The cause of the sail sign was assessed using computed tomography (CT). The sail sign was revealed in 10 (seven males, three females; median age 60.6 years) of 10,238 patients. Of these 10 patients with a sail sign on frontal radiographs, eight underwent CT. The frontal radiographs of these 10 patients showed a concave superior margin toward the lung in nine patients, a concave inferior margin in five, and a double-lined inferior margin in three. Lateral radiographs disclosed a focal opacity over the minor fissure in five of six patients, which was either fuzzy (n = 4) or sharp (n = 1) in its upper margin, and was sometimes double lined in the inferior margin (n = 3). CT revealed the anterior mediastinal fat to be the cause of the radiographic sail sign, which stretched laterally from the mediastinum to insinuate into the minor fissure. The incidence of sail sign on adult chest radiographs is about 0.1%. The sign is specific enough to eliminate the need for more sophisticated imaging.

  10. Brazilian young dental practitioners' use and acceptance of digital radiographic examinations

    Energy Technology Data Exchange (ETDEWEB)

    Rovaris, Karla; De Faria Vasconcelos, Karla; Do Nascimento, Eduarda Helena Leandro; Oliveira, Matheus Lima; Freitas, Deborah Queiroz; Haiter-Neto, Francisco [Div. of Oral Radiology, Dept. of Oral Diagnosis, Piracicaba Dental School, University of Campinas (UNICAMP), Sao Paulo (Brazil)

    2016-12-15

    The aim of this study was to investigate the use and acceptance of digital radiographic examinations by Brazilian dental practitioners in daily practice and to evaluate the advances that have occurred over the past 5 years. Dental practitioners enrolled in extension courses at the Piracicaba Dental School, University of Campinas, Brazil, responded to a self-administered questionnaire in the years 2011 and 2015. They were asked about sociodemographic factors and their knowledge and use of digital radiographic examinations. Descriptive analysis was performed, as well as the chi-square and Fisher exact tests, with a significance level of 5% (α=0.05). A total of 181 participants responded to the questionnaire in the years 2011 and 2015. Most of the respondents worked in private practice, had graduated within the last 5 years, and were between 20 and 30 years old. In 2011, 55.6% of respondents reported having ever used digital radiographic examinations, while in 2015 this number increased significantly to 85.4% (p<.0001), out of which 71.4% preferred it to conventional images. Moreover, 21.4% of respondents reported having used digital radiographic examinations for more than 3 years. A significant increase in use of intraoral digital radiography (p=0.0316) was observed in 2015. In both years, image quality and high cost were indicated, respectively, as the main advantage and disadvantage of digital radiographic examinations. This study showed that digital radiology has become more common in Brazil over the past 5 years. Most of the Brazilian dental practitioners evaluated in 2015 used digital radiographic examinations.

  11. European radiographers' challenges from mammography education and clinical practice - an integrative review.

    Science.gov (United States)

    Metsälä, Eija; Richli Meystre, Nicole; Pires Jorge, José; Henner, Anja; Kukkes, Tiina; Sá Dos Reis, Cláudia

    2017-06-01

    This study aims to identify European radiographers' challenges in clinical performance in mammography and the main areas of mammography that require more and better training. An extensive search was performed to identify relevant studies focused on clinical practice, education and training in mammography published between January 2010 and December 2015 in the English language. The data were analysed by using deductive thematic analysis. A total of 27 full text articles were read, evaluating their quality. Sixteen articles out of 27 were finally selected for this integrative review. The main challenges of radiographers' mammography education/training can be divided into three groups: training needs, challenges related to radiographers, and challenges related to the organization of education. The most common challenges of clinical performance in mammography among European radiographers involved technical performance, the quality of practices, and patient-centeredness. The introduction of harmonized mammography guidelines across Europe may serve as an evidence-based tool to be implemented in practice and education. However, the variability in human and material resources as well as the different cultural contexts should be considered during this process. • Radiographers' awareness of their professional identity and enhancing multiprofessional cooperation in mammography. • Radiographers' responsibilities regarding image quality (IQ) and optimal breast imaging performance. • Patient-centred mammography services focusing on the psychosocial needs of the patient. • Challenges: positioning, QC-testing, IQ-assessment, optimization of breast compression, communication, teamwork, and patient-centred care. • Introduction of evidence-based guidelines in Europe to harmonize mammography practice and education.

  12. Chest Radiographic Findings in Primary Pulmonary Tuberculosis: Observations from High School Outbreaks

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Won Jung; Kwon, O Jung; Lee, Kyung Soo [Sungkyunkwan University School of Medicine, Samsung Medical Center, Seoul (Korea, Republic of); Jeong, Yeon Joo [Pusan National University School of Medicine, Pusan National University Hospital, Busan (Korea, Republic of); Kim, Hee Jin; Lew, Woo Jin [Korean Institute of Tuberculosis, Seoul (Korea, Republic of); Cho, En Hi [4Korea Centers for Disease Control and Prevention, Seoul (Korea, Republic of)

    2010-12-15

    To describe the radiographic findings of primary pulmonary tuberculosis (TB) in previously healthy adolescent patients. The Institutional Review Board approved this retrospective study, with a waiver of informed consent from the patients. TB outbreaks occurred in 15 senior high schools and chest radiographs from 58 students with identical strains of TB were analyzed by restriction fragment length polymorphism analysis by two independent observers. Lesions of nodule(s), consolidation, or cavitation in the upper lung zones were classified as typical TB. Mediastinal lymph node enlargement; lesions of nodule(s), consolidation, or cavitation in lower lung zones; or pleural effusion were classified as atypical TB. Inter-observer agreement for the presence of each radiographic finding was examined by kappa statistics. Of 58 patients, three (5%) had normal chest radiographs. Cavitary lesions were present in 25 (45%) of 55 students. Lesions with upper lung zone predominance were observed in 27 (49%) patients, whereas lower lung zone predominance was noted in 18 (33%) patients. The remaining 10 (18%) patients had lesions in both upper and lower lung zones. Pleural effusion was not observed in any patient, nor was the mediastinal lymph node enlargement. Hilar lymph node enlargement was seen in only one (2%) patient. Overall, 37 (67%) students had the typical form of TB, whereas 18 (33%) had TB lesions of the atypical form. The most common radiographic findings in primary pulmonary TB by recent infection in previously healthy adolescents are upper lung lesions, which were thought to be radiographic findings of reactivation pulmonary TB by remote infection

  13. Common pitfalls in radiographic interpretation of the Thorax

    International Nuclear Information System (INIS)

    Godshalk, C.P.

    1994-01-01

    Errors in radiographic interpretation of the thorax are common. Many mistakes result from interpreting normal anatomic variants as abnormalstructures, such as misdiagnosing dorsal and rightward deviation of the cranial thoracic trachea on lateral radiographs of normal dogs. Some of the more common errors specifically relate to misinterpretation of radiographs made on obese patients. The age of the patient also plays a role in misdiagnosis. Aging cats seem to have a horizontally positioned heart on lateral radiographs, and older dogs, primarily collies,often have pulmonary osteomas that are misdiagnosed as metastatic neoplastic disease or healed pulmonary fungal infections

  14. Method for taking X radiographs

    International Nuclear Information System (INIS)

    Orth, G.

    1983-01-01

    The method is aimed at obtaining X radiographs of any human organ with the aid of an X-ray-shadowless radiation detector of a dose measuring device, which is arranged between patient and imaging system, and of a controlling microprocessor system, so that the image-forming parameters are automatically adjusted to the specific properties of the patient. This procedure minimices the efforts in preparing the radiograph and the radiation exposure of the patient

  15. Neonates do not need to be handled for radiographs

    International Nuclear Information System (INIS)

    Slade, Dawn; Alfaham, Mazin; Davis, Peter; Tuthill, David; Harrison, Sara; Morris, Susan; Guildea, Zoe

    2005-01-01

    The handling of sick neonates may have detrimental effects such as hypoxia or bradycardia. Such handling is inevitable due to the frequent need for practical procedures; however, minimising handling reduces these adverse events and may improve outcome. Radiography is one of the commonest procedures performed on neonates. Usually the infant is lifted and placed onto the radiographic cassette; however, modern incubators often incorporate a tray beneath the mattress in which the radiographic cassette can be placed without the need to disturb the infant. To compare the quality of chest radiographs taken using the standard direct contact method, with those taken using the under-tray technique. A series of chest radiographs taken over a 21-month period were analysed independently by two consultant paediatric radiologists unaware of the radiographic details. The position of the radiograph, i.e. direct contact or under-tray, was determined by the radiographer. Radiographic quality was scored on the following features: exposure, blurring, rotation, cut-off or coning, and side markers. A subjective score was also included. The results from each radiologist were analysed separately. Seventy chest radiographs were analysed - 25 standard method, 45 under-tray. A statistically significant advantage for the under-tray method was seen on two analyses - radiologist 1 for exposure, and radiologist 2 for cut-off. No other significant differences were noted. There were no differences in the infants' weights or radiation exposure. The under-tray method for taking radiographs may produce films of at least equivalent quality to the standard method. Since the standard method involves handling with potential desaturation and bradycardia, this technique should cease. (orig.)

  16. Radiographic evaluation of dentigerous cyst with cone beam CT

    International Nuclear Information System (INIS)

    Park, Yong Chan; Lee, Wan; Lee, Byung Do

    2010-01-01

    The purpose of this study was to accurately analyze the radiographic characteristics of dentigerous cyst (DC) with multiplanar images of cone beam computed tomography (CBCT). Thirty eight radiographically and histopathologically proven cases of DCs were analyzed with panoramic radiograph and CBCT, retrospectively. The radiographic CT pattern, symmetry of radiolucency around the unerupted tooth crown, ratio of long length to short length, degree of cortical bone alternation, effects on adjacent tooth, and cyst size were analyzed. Relative frequencies of these radiographic features were evaluated. In order to compare the CBCT features of DC with those of odontogenic keratocyst (OKC), 9 cases of OKCs were analyzed with the same method radiographically. DCs consisted of thirty unilocular cases (79.0%), seven lobulated cases (18.4%) and one multilocular case (2.6%). Eight were asymmetric (21.0%) and thirty were symmetric (79.0%). Maxillary DC showed rounder shape than mandibular DC (L/S ratio; maxilla 1.32, mandible 1.67). Alternations of lingual cortical bone (14 cases, 48.2%) were more frequent than those of buccal side (7 cases, 24.1%). CBCT images of DC showed definite root resorption and bucco-lingual tooth displacement. These findings were hardly observed on panoramic radiographs of DCs. Comparison of CBCT features of DC with those of OKC showed several different features. CBCT images of DC showed various characteristic radiographic features. Therefore, CBCT can be helpful for the diagnosis of DC radiographically.

  17. Radiographic evaluation of dentigerous cyst with cone beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yong Chan; Lee, Wan; Lee, Byung Do [School of Dentisity, Wonkwang University, Iksan (Korea, Republic of)

    2010-09-15

    The purpose of this study was to accurately analyze the radiographic characteristics of dentigerous cyst (DC) with multiplanar images of cone beam computed tomography (CBCT). Thirty eight radiographically and histopathologically proven cases of DCs were analyzed with panoramic radiograph and CBCT, retrospectively. The radiographic CT pattern, symmetry of radiolucency around the unerupted tooth crown, ratio of long length to short length, degree of cortical bone alternation, effects on adjacent tooth, and cyst size were analyzed. Relative frequencies of these radiographic features were evaluated. In order to compare the CBCT features of DC with those of odontogenic keratocyst (OKC), 9 cases of OKCs were analyzed with the same method radiographically. DCs consisted of thirty unilocular cases (79.0%), seven lobulated cases (18.4%) and one multilocular case (2.6%). Eight were asymmetric (21.0%) and thirty were symmetric (79.0%). Maxillary DC showed rounder shape than mandibular DC (L/S ratio; maxilla 1.32, mandible 1.67). Alternations of lingual cortical bone (14 cases, 48.2%) were more frequent than those of buccal side (7 cases, 24.1%). CBCT images of DC showed definite root resorption and bucco-lingual tooth displacement. These findings were hardly observed on panoramic radiographs of DCs. Comparison of CBCT features of DC with those of OKC showed several different features. CBCT images of DC showed various characteristic radiographic features. Therefore, CBCT can be helpful for the diagnosis of DC radiographically.

  18. New View on the Initial Development Site and Radiographic Classification System of Osteoarthritis of the Knee Based on Radiographic Analysis

    OpenAIRE

    Moon, Ki-Ho

    2012-01-01

    Introduction: Radiographic pathology of severe osteoarthritis of the knee (OAK) such as severe osteophyte at tibial spine (TS), compartment narrowing, marginal osteophyte, and subchondral sclerosis is well known. Kellgren-Lawrence grading system, which is widely used to diagnose OAK, describes narrowing-marginal osteophyte in 4-grades but uses osteophyte at TS only as evidence of OAK without detailed-grading. However, kinematically the knee employs medial TS as an axis while medial and latera...

  19. Radiographic screening of edentulous patients: sense or nonsense? A risk-benefit analysis

    International Nuclear Information System (INIS)

    Keur, J.J.

    1986-01-01

    The benefits of radiographic examination of symptomless edentulous patients are presented. Based on data from the literature, an estimate of the risk of fatal malignancy from such a procedure is provided. Because the benefits are considerable and the risks low, a recommendation for selective screening of edentulous patients is made

  20. Appearance of the mandibular incisive canal on panoramic radiographs

    NARCIS (Netherlands)

    Jacobs, R.; Mraiwa, N.; van Steenberghe, D.; Sanderink, G.C.H.; Quirynen, M.

    2004-01-01

    Panoramic radiographs are routinely used in the dental office for various diagnostic purposes. This study aimed to evaluate the visibility of neurovascular structures in the mandibular interforaminal region on such radiographs. Panoramic radiographs were obtained with a Cranex Tome (Soredex) from

  1. Concept Analysis: Alzheimer’s Caregiver Stress

    Science.gov (United States)

    Llanque, Sarah; Savage, Lynette; Rosenburg, Neal; Honor’s, BA; Caserta, Michael

    2015-01-01

    AIM The aim of this article was to analyze the concept of caregiver stress in the context of caring for a person with Alzheimer’s disease and related dementias. BACKGROUND Currently, there are more than 15 million unpaid care-givers for persons suffering from Alzheimer’s disease and related dementias. This unpaid care can be stressful for caregivers due to the chronic nature of the disease process, as well as other factors. METHOD The paper incorporates the modified method of Wilson’s concept analysis procedure to analyze the concept of caregiver stress. DATA SOURCES A review of the literature was undertaken using the Cumulative Index to Nursing and Allied Health Literature, Google Scholar, and PubMed. RESULTS A theoretical definition of caregiver stress is provided, and the defining attributes, related concepts, antecedents, and consequences of caregiver stress are proposed, and case studies are presented. CONCLUSIONS The analysis demonstrates that caregiver stress is the unequal exchange of assistance among people who stand in close relationship to one another, which results in emotional and physical stress on the caregiver. Implications for future nursing research and practice conclude the paper. PMID:24787468

  2. Stress analysis of PCV nozzle junction

    International Nuclear Information System (INIS)

    Uchiyama, Shoichi; Oikawa, Tsuneo; Hoshino, Seizo

    1976-01-01

    Most of various pressure vessels comprise each one cylindrical shell and one or more nozzles. In this study, in order to analyze the stress in the structures of this type as minutely and exactly as possible, the program for stress analysis by the finite element method was made, which is required for the strength analysis for three-dimensional structures. Especially, the problem of the stress distribution around nozzle junctions was solved theoretically with the program. The program for the analysis developed in this study is provided with various functions, such as the input generator for cylindrical, conical and spherical shells, and plotter, and is very covenient. The accuracy of analysis is very good. The method of analysis and the calculation of the rigidity matrices for the deformation in plane and bending are explained. The result of the stress analysis around the nozzle junctions of a containment vessel with this program was in good agreement with experimental data and the result with SAP-4 code, therefore the propriety of the calculated result with this program was proved. Also calculations were carried out on three cases, namely a flat plate fixed at one end with distributed load, a cylinder fixed at one end with internal pressure, and an I-beam fixed at one end with concentrated load. The calculated results agreed well with theoretical solutions in all cases. (Kako, I.)

  3. Analysis of biological tissues in infant chest for the development of an equivalent radiographic phantom

    International Nuclear Information System (INIS)

    Pina, D. R.; Souza, Rafael T. F.; Duarte, Sergio B.; Alvarez, Matheus; Miranda, Jose R. A.

    2012-01-01

    Purpose: The main purpose of the present study was to determine the amounts of different tissues in the chest of the newborn patient (age ≤1 year), with the aim of developing a homogeneous phantom chest equivalent. This type of phantom is indispensable in the development of optimization procedures for radiographic techniques, including dosimetric control, which is a crucial aspect of pediatric radiology. The authors present a systematic set of procedures, including a computational algorithm, to estimate the amounts of tissues and thicknesses of the corresponding simulator material plates used to construct the phantom. Methods: The Gaussian fit of computed tomographic (CT) analysis was applied to classify and quantify different biological tissues. The methodology is summarized with a computational algorithm, which was used to quantify tissues through automated CT analysis. The thicknesses of the equivalent homogeneous simulator material plates were determined to construct the phantom. Results: A total of 180 retrospective CT examinations with anterior-posterior diameter values ranging 8.5-13.0 cm were examined. The amounts of different tissues were evaluated. The results provided elements to construct a phantom to simulate the infant chest in the posterior-anterior or anterior-posterior (PA/AP) view. Conclusions: To our knowledge, this report represents the first demonstration of an infant chest phantom dedicated to the radiology of children younger than one year. This phantom is a key element in the development of clinical charts for optimizing radiographic technique in pediatric patients. Optimization procedures for nonstandard patients were reported previously [Pina et al., Phys. Med. Biol. 49, N215-N226 (2004) and Pina et al., Appl. Radiat. Isot. 67, 61-69 (2009)]. The constructed phantom represents a starting point to obtain radiologic protocols for the infant patient.

  4. MRI reporting by radiographers: Findings of an accredited postgraduate programme

    Energy Technology Data Exchange (ETDEWEB)

    Piper, Keith [Allied Heath Professions Department, Canterbury Christ Church University, North Holmes Road, Canterbury, Kent CT1 1QU (United Kingdom)], E-mail: keith.piper@canterbury.ac.uk; Buscall, Kaie [Allied Heath Professions Department, Canterbury Christ Church University, North Holmes Road, Canterbury, Kent CT1 1QU (United Kingdom); Thomas, Nigel [X-Ray Department, Trafford General Hospital, Manchester M41 5SL (United Kingdom)

    2010-05-15

    Aim: To analyse the objective structured examination (OSE) results of the first three cohorts of radiographers (n = 39) who completed an accredited postgraduate certificate (PgC) programme in reporting of general magnetic resonance imaging (MRI) investigations and to compare the agreement rates with those demonstrated for a small group of consultant radiologists. Method: Forty MRI investigations were used in the OSE which included the following anatomical areas and abnormal appearances: knee; meniscal/ligament injuries, bone bruises, effusions and osteochondral defects; lumbar spine: intervertebral disc morphology, vertebral collapse, tumours (bone and soft tissue), spinal stenosis and/or nerve root involvement; internal auditory meati (IAM): acoustic neuroma. Incidental findings included maxillary polyp, arachnoid cyst, renal cyst, hydroureter, pleural effusion and metastases (adrenal, lung, perirenal and/or thoracic spine). Sensitivity, specificity and total percentage agreement rates were calculated for all radiographers (n = 39) using all reports (n = 1560). A small representative subgroup of reports (n = 27) was compared to the three consultant radiologists' reports which were produced when constructing the OSE. Kappa values were estimated to measure agreement in four groups: consultant radiologists only; radiographers and each of the consultant radiologists independently. Results: The sensitivity, specificity and agreement rates for the three cohorts (combined) of radiographers were 99.0%, 99.0% and 89.2%, respectively. For the majority (5/9) of anatomical areas and/or pathological categories no significant differences (p < 0.05) were found between the mean Kappa scores (K = 0.47-0.76) for different groups of observers, whether radiographers were included in the group analysis or not. Where differences were apparent, this was in cases (4/9) where the variation was either not greater than found between radiologists and/or of no clinical significance

  5. The radiographic manifestations of hypochondroplasia

    International Nuclear Information System (INIS)

    Heselson, N.G.; Cremin, B.J.; Beighton, P.

    1979-01-01

    Hypochrondroplasia is an inherited skeletal dysplasia that resembles achondroplasia in mild degree. Radiographic manifestations encountered in 12 affected individuals in South Africa include slight shortening of all segments of the tubular bones, moderate caudal diminution of the lumbar interpedicular distances, increased lumbar lordosis with cacral tilt and distal prolongation of the fibular. Hypochondroplasia can be distinguished from other osteochondrodystrophies such as achondroplasia, pseudo-achondroplasia and metaphyseal chondroplasia by the recognition of it clinical and radiographic manifestations. (author)

  6. Industrial radiography on radiographic paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1977-11-01

    An investigation was performed to compare the quality of radiographic paper with that of X-ray film, after a review had been made of the rather scarce literature on the subject. The equipment used throughout the investigation is described, and characteristic curves for Agfa-Gevaert and Kodak papers exposed with different intensifying screens in the low and intermediate voltage range are reproduced. The relative speed, contrast and exposure latitude were computed from these curves. The quality of the radiographic image was checked on U/Al blocks and plates, Al and Fe blocks, and fiber-reinforced composites. Exposure charts for Al and Fe were made for various paper and screen combinations. Both the sharpness of the radiographic image as well as the influence of processing on speed and contrast were checked. Examples are given of the practical application of the paper for radiography of castings, weldings, solderings, assemblies, etc. (author)

  7. Caries detection in dental radiographs

    International Nuclear Information System (INIS)

    Dunn, S.M.

    1987-01-01

    Caries, or the decay of teeth are difficult to automatically detect in dental radiographs because of the small area of the image that is occupied by the decay. Images of dental radiographs has distinct regions of homogeneous gray levels, and therefore naturally lead to a segmentation based automatic caries detection algorithm. This paper describes a method for caries detection based on a multiclass, area independent thresholding and segmenting scheme. This multiclass thresholding algorithm is an extension of the uniform error threshold, an area independent, distribution free thresholding method used for images of only two classes of objects. The authors first consider the problem of caries detection and the image features that characterize the presence of caries. Next, the uniform error threshold is reviewed, and the general multiclass uniform error threshold algorithm is presented. This algorithm is used to automatically detect caries in dental radiographs

  8. Clinical and radiographic assessment of approximal carious lesions

    International Nuclear Information System (INIS)

    Espelid, I.; Tveit, A.B.

    1986-01-01

    The aim of the study was to compare the radiographic diagnosis of approximal carious lesions with visual observations of the approximal surfaces and within drilled Class II cavities (made into the pulp). Sound (n=28) and carious (n=123) approximal surfaces of extracted premolars and molars were radiographed. The radiographs were studied by seven observers to diagnose caries. Lesions without cavitation were most often classified as sound (61.3%). When lesions had cavities, the rate of detection increased to 89.1%. Sound surfaces were erroneously classified as carious in 15.7% of cases. Statistically, about 6 our of every 10 qualitative assessments of lesion depth on the basis of radiographs, correctly recorded lesions as being in enamel or extending into dentin. The interexaminer variation in radiographic caries diagnosis were mostly due to difference in diagnostic criteria, whereas differences in diagnostic capability were less important

  9. A computerized method for automated identification of erect posteroanterior and supine anteroposterior chest radiographs

    International Nuclear Information System (INIS)

    Kao, E-Fong; Chou, Ming-Chung; Lin, Wei-Chen; Hsu, Jui-Sheng; Jaw, Twei-Shiun; Liu, Gin-Chung

    2011-01-01

    A computerized scheme was developed for automated identification of erect posteroanterior (PA) and supine anteroposterior (AP) chest radiographs. The method was based on three features, the tilt angle of the scapula superior border, the tilt angle of the clavicle and the extent of radiolucence in lung fields, to identify the view of a chest radiograph. The three indices A scapula , A clavicle and C lung were determined from a chest image for the three features. Linear discriminant analysis was used to classify PA and AP chest images based on the three indices. The performance of the method was evaluated by receiver operating characteristic analysis. The proposed method was evaluated using a database of 600 PA and 600 AP chest radiographs. The discriminant performances Az of A scapula , A clavicle and C lung were 0.878 ± 0.010, 0.683 ± 0.015 and 0.962 ± 0.006, respectively. The combination of the three indices obtained an Az value of 0.979 ± 0.004. The results indicate that the combination of the three indices could yield high discriminant performance. The proposed method could provide radiologists with information about the view of chest radiographs for interpretation or could be used as a preprocessing step for analyzing chest images.

  10. Early characteristic radiographic changes in mucolipidosis II

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Lillian M. [Lucile Packard Children' s Hospital and Stanford University, Pediatric Radiology, Palo Alto, CA (United States); Lachman, Ralph S. [Lucile Packard Children' s Hospital and Stanford University, Pediatric Radiology, Palo Alto, CA (United States); University of California, International Skeletal Dysplasia Registry, Los Angeles, CA (United States)

    2016-11-15

    Although mucolipidosis type II has similar metabolic abnormalities to those found in all the mucopolysaccharidoses and mucolipidoses, there are distinctive diagnostic radiographic changes of mucolipidosis II in the perinatal/newborn/infant period. To describe the early characteristic radiographic changes of mucolipidosis II and to document when these changes manifest and resolve. We retrospectively reviewed radiographs and clinical records of 19 cases of mucolipidosis II from the International Skeletal Dysplasia Registry (1971-present; fetal age to 21/2 years). A radiologist with special expertise in skeletal dysplasias evaluated the radiographs. The most common abnormalities were increased vertebral body height (80%, nonspecific), talocalcaneal stippling (86%), periosteal cloaking (74%) and vertebral body rounding (50%). Unreported findings included sacrococcygeal sclerosis (54%) and vertebral body sclerosis (13%). Rickets and hyperparathyroidism-like (pseudohyperparathyroidism) changes (rarely reported) were found in 33% of cases. These changes invariably started in the newborn period and resolved by 1 year of age. The conversion from these early infantile radiographic features to dysostosis multiplex changes occurred in 41% of cases, and within the first year after birth. Several findings strongly suggest the diagnosis of mucolipidosis II, including cloaking in combination with one or more of the following radiographic criteria: talocalcaneal stippling, sacrococcygeal or generalized vertebral body sclerosis, vertebral body rounding, or rickets/hyperparathyroidism-like changes in the perinatal/newborn/infancy period. These findings are not found in the other two forms of mucolipidosis nor in any of the mucopolysaccharidoses. (orig.)

  11. Early characteristic radiographic changes in mucolipidosis II

    International Nuclear Information System (INIS)

    Lai, Lillian M.; Lachman, Ralph S.

    2016-01-01

    Although mucolipidosis type II has similar metabolic abnormalities to those found in all the mucopolysaccharidoses and mucolipidoses, there are distinctive diagnostic radiographic changes of mucolipidosis II in the perinatal/newborn/infant period. To describe the early characteristic radiographic changes of mucolipidosis II and to document when these changes manifest and resolve. We retrospectively reviewed radiographs and clinical records of 19 cases of mucolipidosis II from the International Skeletal Dysplasia Registry (1971-present; fetal age to 21/2 years). A radiologist with special expertise in skeletal dysplasias evaluated the radiographs. The most common abnormalities were increased vertebral body height (80%, nonspecific), talocalcaneal stippling (86%), periosteal cloaking (74%) and vertebral body rounding (50%). Unreported findings included sacrococcygeal sclerosis (54%) and vertebral body sclerosis (13%). Rickets and hyperparathyroidism-like (pseudohyperparathyroidism) changes (rarely reported) were found in 33% of cases. These changes invariably started in the newborn period and resolved by 1 year of age. The conversion from these early infantile radiographic features to dysostosis multiplex changes occurred in 41% of cases, and within the first year after birth. Several findings strongly suggest the diagnosis of mucolipidosis II, including cloaking in combination with one or more of the following radiographic criteria: talocalcaneal stippling, sacrococcygeal or generalized vertebral body sclerosis, vertebral body rounding, or rickets/hyperparathyroidism-like changes in the perinatal/newborn/infancy period. These findings are not found in the other two forms of mucolipidosis nor in any of the mucopolysaccharidoses. (orig.)

  12. A radiographic study of pediatric ulnar anatomy.

    Science.gov (United States)

    Cravino, Mattia; Oni, Julius K; Sala, Debra A; Chu, Alice

    2014-01-01

    The adult ulna has a unique bony architecture that has been described in the literature, but, to the best of our knowledge, the ulnar anatomy in children has not been described. We examined 75 anteroposterior (AP) and 64 lateral radiographs (29 were bilateral) of 50, 0.5- to 11-year-old, healthy children's forearms. On AP radiographs, the total ulnar length, the ulnar proximal angle, the ulnar distal angle, and the distance between each angle from the tip of the triceps insertion; and, on lateral radiographs, the ulnar length and bow deviation were measured. The correlation between age and radiographic measurements, differences based on sex, differences compared with adults' measurements, and interobserver/intraobserver reliability were assessed. Age had a very strong/strong positive correlation with length/distance measurements on both AP and lateral radiographs. Only AP ulnar distal angle was significantly different between sexes (females > males). Compared with the adult ulnar studies, the AP proximal angle in children is significantly smaller and the location of this angle is significantly more distal. Interobserver and intraobserver reliability were very good for length/distance measurements on AP and lateral radiographs. The knowledge of pediatric ulnar anatomy could be helpful in the treatment of forearm deformities due to multiple hereditary exostosis and osteogenesis imperfecta, and in the treatment of ulnar fractures, particularly in Monteggia variants, where restoration of the correct forearm anatomy is essential to obtain good clinical and functional results. Study of diagnostic test, Level II.

  13. Radiographer performed single contrast small bowel enteroclysis

    International Nuclear Information System (INIS)

    Law, Robert L.; Slack, Nicola; Harvey, Richard F.

    2005-01-01

    Aim: To analyse the technical success and reporting sensitivity of radiographer performed small bowel enteroclysis (SBE) undertaken by a specialist radiographer according to a standard technique [Nolan DJ, Cadman PJ. The small bowel enema made easy. Clinical Radiology 1987;38(3):295-301]. Methods: Patients (1413) had 1646 SBE in 10 years from May 1992 to April 2002. The original request card and the separate radiographer and consultant radiologist reports were reviewed. Where the radiology reports were discordant or inconclusive, the clinical notes were also reviewed. Results: Patients (1022) X-ray films were available. Nine hundred and forty-three (93.3%) SBEs had been successfully completed. Radiographer and consultant radiologist reporting had a 99.3% concordance. There was a 98.4% sensitivity for Crohn's disease (181 of 184 cases where Crohn's disease was the clinical final diagnosis). Overall reporting sensitivity was 93.7% although correct 'probably normal and abnormal' reporting bias suggests a sensitivity of 96.9%. Sixty of 943 (6.4%) reports were inconclusive. Of 1022 patients, 68 (6.6%) of small bowel intubations were not achieved, or else consent was withdrawn at the time of the procedure. Conclusion: Specialist radiographers can perform small bowel enteroclysis with a reporting sensitivity equal to that of a consultant radiologist. Radiographers accustomed to providing an SBE service become skilled at passing fine bore feeding tubes into the small bowel and can provide this service also

  14. Workplace violence-a survey of diagnostic radiographers working in public hospitals in Hong Kong.

    Science.gov (United States)

    Ng, Kris; Yeung, Joanne; Cheung, Ivy; Chung, Andrew; White, Peter

    2009-01-01

    This study aimed to estimate the prevalence of workplace violence involving radiographers in Hong Kong, to evaluate underlying factors contributing to incidents and their impact, and to suggest improvements in management and training. Frontline radiographers, from seven regional hospitals, who performed duties in general radiography, were provided with a workplace violence questionnaire. General radiography refers to plain film X-ray services in general rooms (including out patient clinics), A&E and portable services on wards. Materials relating to workplace violence, for example guidelines and training information, were provided by hospital managers. Out of 281 questionnaires, 150 were returned (response rate of 53%). Sixty-one percent of radiographers had experienced violence in the past 3 yr and 34% of victims had encountered incidents more than 5 times. From respondents who had experienced abuse, verbal abuse (97%) was most frequently reported, and the predominant source of violence was patients (pwork stress, job dissatisfaction, depression and increased sick leave, were highlighted as negative consequences of violence. 77% of respondents felt that support from departments was inadequate and only 11% had attended courses on prevention of occupational violence. Workplace violence is a critical problem in Hong Kong. Further research is recommended to investigate the problem.

  15. Radiographic findings in pulmonary hypertension from unresolved embolism

    Energy Technology Data Exchange (ETDEWEB)

    Woodruff, W.W. III; Hoeck, B.E.; Chitwood, W.R. Jr.; Lyerly, H.K.; Sabiston, D.C. Jr.; Chen, J.T.T.

    1985-04-01

    Pulmonary artery hypertension with chronic pulmonary embolism is an uncommon entity that is potentially treatable with pulmonary embolectomy. Although the classic radiographic features have been described, several recent investigators report a significant percentage of these patients with normal chest radiographs. In a series of 22 patients, no normal radiographs were seen. Findings included cardiomegaly (86.4%) with right-sided enlargement (68.4%), right descending pulmonary artery enlargement (54.5%), azygos vein enlargement (27.3%), mosaic oligemia (68.2%), chronic volume loss (27.3%), atelectasis and/or effusion (22.7%), and pleural thickening (13.6%). Good correlation with specific areas of diminished vascularity was seen on chest radiographs compared with pulmonary angiograms.

  16. Radiographic findings in pulmonary hypertension from unresolved embolism

    International Nuclear Information System (INIS)

    Woodruff, W.W. III; Hoeck, B.E.; Chitwood, W.R. Jr.; Lyerly, H.K.; Sabiston, D.C. Jr.; Chen, J.T.T.

    1985-01-01

    Pulmonary artery hypertension with chronic pulmonary embolism is an uncommon entity that is potentially treatable with pulmonary embolectomy. Although the classic radiographic features have been described, several recent investigators report a significant percentage of these patients with normal chest radiographs. In a series of 22 patients, no normal radiographs were seen. Findings included cardiomegaly (86.4%) with right-sided enlargement (68.4%), right descending pulmonary artery enlargement (54.5%), azygos vein enlargement (27.3%), mosaic oligemia (68.2%), chronic volume loss (27.3%), atelectasis and/or effusion (22.7%), and pleural thickening (13.6%). Good correlation with specific areas of diminished vascularity was seen on chest radiographs compared with pulmonary angiograms

  17. Influenza A H1N1 pneumonia: radiograph and CT features of children

    International Nuclear Information System (INIS)

    Cheng Hua; Duan Xiaomin; Peng Yun; Zeng Jinjin; Sun Guoqiang

    2010-01-01

    Objective: To explore the imaging features on chest radiograph and CT in children with Influenza A H1N1 pneumonia. Methods: The imaging data of chest radiograph and CT in six children with Influenza A H1N1 pneumonia confirmed by real-time RT-PCR assay was retrospectively analysis. All patients had chest radiograph at first examination and 4 of them re-examed. One children took CT. Results: All cases showed thick lung markings with varied degrees of pulmonary infiltration and interstitial changes on chest radiograph. Among them, 3 cases showed bilateral pulmonary infiltration and 3 cases showed infiltration in left lung; enlarged hilar was observed in 3 cases. The imaging findings of the pneumonia changed quickly during the follow-up accompanied with the improvement of clinical symptoms. The only one chest CT examination showed bilateral infiltration, multiple ground-glass opacities, small subpleural nodulars, right pleural effusion and lymphadenopathy of lung hila and mediastinum. Conclusions: Chest radiograph and CT revealed certain typical imaging features in the children with influenza A H1N1 pneumonia. However, the final diagnosis of influenza A H1N1 pneumonia still should be made based on epidemiology and laboratory examination. (authors)

  18. Reporting instructions significantly impact false positive rates when reading chest radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, John W.; Brennan, Patrick C.; Mello-Thoms, Claudia; Lewis, Sarah J. [The University of Sydney, Medical Image Optimisation and Perception Group, Discipline of Medical Radiation Sciences, Faculty of Health Sciences, Lidcombe, NSW (Australia)

    2016-10-15

    To determine the impact of specific reporting tasks on the performance of radiologists when reading chest radiographs. Ten experienced radiologists read a set of 40 postero-anterior (PA) chest radiographs: 21 nodule free and 19 with a proven solitary nodule. There were two reporting conditions: an unframed task (UFT) to report any abnormality and a framed task (FT) reporting only lung nodule/s. Jackknife free-response operating characteristic (JAFROC) figure of merit (FOM), specificity, location sensitivity and number of true positive (TP), false positive (FP), true negative (TN) and false negative (FN) decisions were used for analysis. JAFROC FOM for tasks showed a significant reduction in performance for framed tasks (P = 0.006) and an associated decrease in specificity (P = 0.011) but no alteration to the location sensitivity score. There was a significant increase in number of FP decisions made during framed versus unframed tasks for nodule-containing (P = 0.005) and nodule-free (P = 0.011) chest radiographs. No significant differences in TP were recorded. Radiologists report more FP decisions when given specific reporting instructions to search for nodules on chest radiographs. The relevance of clinical history supplied to radiologists is called into question and may induce a negative effect. (orig.)

  19. Reporting instructions significantly impact false positive rates when reading chest radiographs

    International Nuclear Information System (INIS)

    Robinson, John W.; Brennan, Patrick C.; Mello-Thoms, Claudia; Lewis, Sarah J.

    2016-01-01

    To determine the impact of specific reporting tasks on the performance of radiologists when reading chest radiographs. Ten experienced radiologists read a set of 40 postero-anterior (PA) chest radiographs: 21 nodule free and 19 with a proven solitary nodule. There were two reporting conditions: an unframed task (UFT) to report any abnormality and a framed task (FT) reporting only lung nodule/s. Jackknife free-response operating characteristic (JAFROC) figure of merit (FOM), specificity, location sensitivity and number of true positive (TP), false positive (FP), true negative (TN) and false negative (FN) decisions were used for analysis. JAFROC FOM for tasks showed a significant reduction in performance for framed tasks (P = 0.006) and an associated decrease in specificity (P = 0.011) but no alteration to the location sensitivity score. There was a significant increase in number of FP decisions made during framed versus unframed tasks for nodule-containing (P = 0.005) and nodule-free (P = 0.011) chest radiographs. No significant differences in TP were recorded. Radiologists report more FP decisions when given specific reporting instructions to search for nodules on chest radiographs. The relevance of clinical history supplied to radiologists is called into question and may induce a negative effect. (orig.)

  20. STRESS FRACTURE OF THE ULNA IN A BREAK-DANCER

    Directory of Open Access Journals (Sweden)

    Yu-Hsu Chen

    2008-12-01

    Full Text Available Break dancing is a popular activity in teenagers and is associated with severe trauma to bones and tissues. We report the first known case of a break dancer with an ulnar stress fracture. Such injuries occur in a variety of sports due to substantial stress on the ulna and repetitive excessive rotation of the forearm. In this study we describe a patient who experienced an ulnar stress fracture during break dancing training. The diagnosis was established by history and physical examination. Initial radiographic findings were negative. However, radiographs taken 3 months after initial presented revealed callus formation over the ulnar shaft. This suggested that readjustment is required in break dancing training protocols. It is important to increase awareness of this injury among physicians to expedite the diagnosis and to prevent the possibility of conversion to an overt fracture in the future

  1. Interphalangeal Osteoarthritis Radiographic Simplified (iOARS) score: a radiographic method to detect osteoarthritis of the interphalangeal finger joints based on its histopathological alterations.

    Science.gov (United States)

    Sunk, Ilse-Gerlinde; Amoyo-Minar, Love; Stamm, Tanja; Haider, Stefanie; Niederreiter, Birgit; Supp, Gabriela; Soleiman, Afschin; Kainberger, Franz; Smolen, Josef S; Bobacz, Klaus

    2014-11-01

    To develop a radiographic score for assessment of hand osteoarthritis (OA) that is based on histopathological alterations of the distal (DIP) and proximal (PIP) interphalangeal joints. DIP and PIP joints were obtained from corpses (n=40). Plain radiographies of these joints were taken. Joint samples were prepared for histological analysis; cartilage damage was graded according to the Mankin scoring system. A 2×2 Fisher's exact test was applied to define those radiographic features most likely to be associated with histological alterations. Receiver operating characteristic curves were analysed to determine radiographic thresholds. Intraclass correlation coefficients (ICC) estimated intra- and inter-reader variability. Spearman's correlation was applied to examine the relationship between our score and histopathological changes. Differences between groups were determined by a Student's t test. The Interphalangeal Osteoarthritis Radiographic Simplified (iOARS) score is presented. The score is based on histopathological changes of DIP and PIP joints and follows a simple dichotomy whether OA is present or not. The iOARS score relies on three equally ranked radiographic features (osteophytes, joint space narrowing and subchondral sclerosis). For both DIP and PIP joints, the presence of one x-ray features reflects interphalangeal OA. Sensitivity and specificity for DIP joints were 92.3% and 90.9%, respectively, and 75% and 100% for PIP joints. All readers were able to reproduce their own readings in DIP and PIP joints after 4 weeks. The overall agreement between the three readers was good; ICCs ranged from 0.945 to 0.586. Additionally, outcomes of the iOARS score in a hand OA cohort revealed a higher prevalence of interphalangeal joint OA compared with the Kellgren and Lawrence score. The iOARS score is uniquely based on histopathological alterations of the interphalangeal joints in order to reliably determine OA of the DIP and PIP joints radiographically. Its high

  2. Evaluation of underexposed conventional radiographs after digitization

    International Nuclear Information System (INIS)

    Wenz, W.

    1993-01-01

    Inadequate exposure of analogue radiographs is reported in the literature to occur in 5-25% of cases. Therefore, the present study was performed to test whether selective image processing after digitization could reveal diagnostic details on underexposed radiographs. In addition, the minimal exposure values required for diagnostic purposes after adequate image processing were studied. Phantom studies, organ preparations and measurements of physical parameters with decreasing exposure values were performed. The detection of anatomic and pathologic (nondisplaced fracture lines, microcalcification and renal stones) structures were evaluated by 12 readers. Radiographs with exposure values 20-40% lower than 'ideal' values can provide adequate diagnostic images after digital processing. The diagnostic information is significantly impaired with values under 50% of the correct exposure values. In conclusion, this method is adequate to save underexposed radiographs for diagnostic purposes and to avoid repeated examinations. (orig.) [de

  3. Do general radiographic examinations resemble a person-centred environment?

    International Nuclear Information System (INIS)

    Hayre, C.M.; Blackman, S.; Eyden, A.

    2016-01-01

    Aim and objective: It is argued whether general radiographic examinations adhere to a person-centred approach within the direct digital radiography (DDR) environment. General radiographic examinations continue to increase and constitute approximately 90% of all examinations undertaken in the clinical environment. This study explored the potential impact patients experience whilst undergoing general imaging examinations. Method: An ethnographic methodology provided insight of two general radiography environments in the United Kingdom (UK) using participant observation and semi-structured interviews. Findings: The findings highlighted an ‘in and out’ culture whereby patients are ‘hurried’ and ‘rushed’ out of X-ray rooms in response to increasing time pressures experienced by diagnostic radiographers. In addition, this study challenged that patients may begin to rank ‘speed’ and ‘waiting times’ above other elements of radiographic care thus presenting new challenges for radiographers within the clinical environment. Conclusion: It is asserted that radiographers should remain holistic healthcare professionals and not begin to resemble operators on the production line. Further, it challenges whether patients are beginning to rank aspects of radiographic care within contemporary practices. Advances in knowledge: Few studies have explored the radiographer–patient relationship within the DDR environment, yet this study provides insight of person-centred practices within contemporary practices. - Highlights: • Challenges whether the use of DDR conforms to a person-centred approach. • Challenges whether radiographers are ‘treating patients as persons’ using DDR. • Patients may begin to rank ‘speed’ and ‘waiting times’ above other aspects of radiographic care.

  4. A case of a found radiographic source

    International Nuclear Information System (INIS)

    Pucelj, B.; Korun, M.; Kavsek, D.; Kreft, Z.; Krizman, M.; Martincic, R.; Rosman, M.; Sutej, T.

    1996-01-01

    High dose-rate levels were detected outdoors in the vicinity of a bunker used for storage of radiographic sources in a plant which manufactures metallic products. The investigation revealed that radiation was due to a buried sealed radiographic source, containing 28 GBq of 137 Cs. A special republic radiological emergency team removed the source in a carefully planned operation. There was no evidence for overexposure of the population or of radiographic and other workers of the plant. The highest dose to the recovery team was 50 μSv

  5. Reader characteristics linked to detection of pulmonary nodules on radiographs: ROC vs. JAFROC analyses of performance

    Science.gov (United States)

    Kohli, Akshay; Robinson, John W.; Ryan, John; McEntee, Mark F.; Brennan, Patrick C.

    2011-03-01

    The purpose of this study is to explore whether reader characteristics are linked to heightened levels of diagnostic performance in chest radiology using receiver operating characteristic (ROC) and jackknife free response ROC (JAFROC) methodologies. A set of 40 postero-anterior chest radiographs was developed, of which 20 were abnormal containing one or more simulated nodules, of varying subtlety. Images were independently reviewed by 12 boardcertified radiologists including six chest specialists. The observer performance was measured in terms of ROC and JAFROC scores. For the ROC analysis, readers were asked to rate their degree of suspicion for the presence of nodules by using a confidence rating scale (1-6). JAFROC analysis required the readers to locate and rate as many suspicious areas as they wished using the same scale and resultant data were used to generate Az and FOM scores for ROC and JAFROC analyses respectively. Using Pearson methods, scores of performance were correlated with 7 reader characteristics recorded using a questionnaire. JAFROC analysis showed that improved reader performance was significantly (pchest specialty (pchest radiographs (pchest readings per year (pchest radiographs (pchest specialty, hours reading per week and number of radiographs read per year. Also, JAFROC is a more powerful predictor of performance as compared to ROC.

  6. Radiographic findings in immunodeficiency

    International Nuclear Information System (INIS)

    Obregon, R.; Lynch, D.A.; Cink, T.M.; Newell, J.D.; Kirkpatrick, C.

    1991-01-01

    This paper reviews the chest radiographs and high-resolution CT (HRCT) scans in patients with immunodeficiency disorders and define the role of HRCT. Thirty-three cases were retrospectively graded according to the consensus of two radiologists. Patients with HIV seropositivity and asthma were excluded. HRCT was performed in 12 cases with standard techniques. Diagnoses included common variable hypogammaglobulinemia (n = 19), X-linked agammaglobulinemia (n = 4), chronic mucocutaneous candidiasis (n = 4), and selective immunoglobulin g deficiencies (n = 2). Chest radiographs showed bronchiectasis in 11 of 33 cases with a predominant lower lobe distribution (82%). Nodules were present in six cases and mucus plugs in four cases. HRCT showed bronchiectasis in nine of 12 cases; in five of these nine cases, bronchiectasis was not apparent on chest radiographs. Other HRCT findings included segmental air trapping (four of 12), mucus plugs (three of 12), hazy consolidation (four of 12), nodules (five of 12), and bronchiolectasis (two of 12). Therapy was altered in seven of 12 cases in which HRCT was performed. Most pertinent to clinical management were the presence of a thymoma (n = 1) and severe focal of diffuse bronchiectasis

  7. Large Format Radiographic Imaging

    International Nuclear Information System (INIS)

    Rohrer, J. S.; Stewart, Lacey; Wilke, M. D.; King, N. S.; Baker A, S.; Lewis, Wilfred

    1999-01-01

    Radiographic imaging continues to be a key diagnostic in many areas at Los Alamos National Laboratory (LANL). Radiographic recording systems have taken on many form, from high repetition-rate, gated systems to film recording and storage phosphors. Some systems are designed for synchronization to an accelerator while others may be single shot or may record a frame sequence in a dynamic radiography experiment. While film recording remains a reliable standby in the radiographic community, there is growing interest in investigating electronic recording for many applications. The advantages of real time access to remote data acquisition are highly attractive. Cooled CCD camera systems are capable of providing greater sensitivity with improved signal-to-noise ratio. This paper begins with a review of performance characteristics of the Bechtel Nevada large format imaging system, a gated system capable of viewing scintillators up to 300 mm in diameter. We then examine configuration alternatives in lens coupled and fiber optically coupled electro-optical recording systems. Areas of investigation include tradeoffs between fiber optic and lens coupling, methods of image magnification, and spectral matching from scintillator to CCD camera. Key performance features discussed include field of view, resolution, sensitivity, dynamic range, and system noise characteristics

  8. Radiographic study on temporomandibular joint Arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Dong Soo [Dept. of Radiology, College of Dentistry, Seoul National University , Seoul (Korea, Republic of)

    1980-11-15

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  9. Radiographic study on temporomandibular joint Arthrosis

    International Nuclear Information System (INIS)

    Yoo, Dong Soo

    1980-01-01

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  10. The lived experience of newly qualified radiographers (1950-1985): An oral history of radiography

    International Nuclear Information System (INIS)

    Decker, Sola

    2009-01-01

    The preparedness for practice of newly qualified healthcare professionals (including radiographers) has been the focus of attention in recent years as the practice environment continues to place great demands on its workforce. This paper reports an aspect of the findings from an oral history project on the career history of radiographers conducted as an academic research investigating the changes that have occurred in radiography and the impact these have had on the profession and the practice of radiography. The main focus of this paper is the lived experience of the informants of the oral history project as newly qualified radiographers. The findings are discussed in the context of current practice environment and developments in radiography. Analysis of the textual materials generated from informants' oral historical accounts, suggest radiographers trained in this time frame perceived their training as 'fit for purpose. The findings further suggest there is a general norm of 'get-on-with-it' as a coping strategy which is still prevalent in the profession today. The paper concludes by drawing on lessons that can be learned from the lived experiences of radiographers' oral historical accounts.

  11. Topographical evaluation of the mandibular canal through panoramic radiograph

    Directory of Open Access Journals (Sweden)

    Ingrid Macedo Oliveira

    2016-10-01

    Full Text Available The mandibular canal is located inside the body of the mandible and may have anatomical variations. The topographic knowledge of the mandibular canal by the Dental surgeons is fundamental to achieving success in surgical planning, anesthetics and clinical interventions involving the jaw. To study the anatomy of the mandibular canal through panoramic radiographs. A retrospective descriptive study, developed after review and approval by the Ethics and Research Committee with the number of opinion 431095. Were analyzed 252 panoramic radiographs of patients of male and female attended in dental clinics UNINOVAFAPI University Center, Teresina-Pi, Brazil. The radiographs were analyzed with the aid of a light box and each antimere the jaw was observed separately. The classification of Nortjé and Langlais for description of the topography of the mandibular canal were used. Descriptive statistical analysis was performed with SPSS version 18.0. There was a prevalence of 38.89% in both antimeres, of mandibular channel the Type II. The type IV was present in 25.4% in the right hemi-arch and 26.6% on the left. Mandibular canal with unilateral bifurcation was observed in 0.77% of the sample and molar straight channel has not been identified. We observed anatomical variations as for the number and path, of the mandibular canal with the highest prevalence of Types II and IV, and the absence of bifurcations. Most was mandibular channels showed no bifurcation. The panoramic radiograph showed up an aid important to identify the mandibular canal and its variations.

  12. Black Lung Benefits Act: standards for chest radiographs. Final rule.

    Science.gov (United States)

    2014-04-17

    Physicians and adjudicators use chest radiographs (X-rays) as a tool in evaluating whether a coal miner suffers from pneumoconiosis (black lung disease). Accordingly, the Department's regulations implementing the Black Lung Benefits Act allow the submission of radiographs in connection with benefit claims and set out quality standards for administering and interpreting film-based chest radiographs. This final rule updates the Department's existing film-radiograph standards and provides parallel standards for digital radiographs. This rule also updates outdated terminology and removes certain obsolete provisions.

  13. Automatic Cobb Angle Determination From Radiographic Images

    NARCIS (Netherlands)

    Sardjono, Tri Arief; Wilkinson, Michael H. F.; Veldhuizen, Albert G.; van Ooijen, Peter M. A.; Purnama, Ketut E.; Verkerke, Gijsbertus J.

    2013-01-01

    Study Design. Automatic measurement of Cobb angle in patients with scoliosis. Objective. To test the accuracy of an automatic Cobb angle determination method from frontal radiographical images. Summary of Background Data. Thirty-six frontal radiographical images of patients with scoliosis. Methods.

  14. Radiographic analysis of 1000 cast posts in Sergipe state, Brazil

    Directory of Open Access Journals (Sweden)

    Caroline Garcez MENDONÇA

    2017-09-01

    Full Text Available Abstract Introduction Endodontically treated teeth with extensive coronary destruction require posts and cores to enable prosthetic restoration. Despite the increasing use of prefabricated posts, cast metal posts and cores are still widely used. The quality of the latter is important for the longevity of restorative treatment, and failure can occur if the fundamental principles are not followed. Objective To radiographically evaluate the prosthetic principles of 1000 cast metal post-and-core restorations performed in single-rooted teeth and their coherence with the principles used for their confection. Material and method Digital periapical radiographs of 1000 endodontically treated, single-rooted teeth with cast metal posts and cores were selected from the collection of a radiology clinic (Centro de Imagem, Aracaju/SE, Brazil. The images were analyzed using a measurement software (ImageJ, USA in accordance with the fundamental prosthetic principles: length and diameter of the post, ratio between post and bone crest, contiguity of post to the root canal, gap between post and the remaining root canal filling, amount of remaining root canal filling, and absence of periapical lesion. The data were qualitatively analyzed, classified into ideal and not ideal, and submitted to the chi-square test (α=0.05. Result Only 6.7% of the cast metal posts analyzed were satisfactorily fabricated. Conclusion Many prosthetic criteria are neglected during the manufacturing of cast metal post and cores, resulting in inadequate work that may compromise the longevity of restorative treatments.

  15. Comparison of tentative radiographic working length with and without grid versus electronic apex locator

    Directory of Open Access Journals (Sweden)

    Tanikonda Rambabu

    2018-01-01

    Full Text Available The apical termination of obturation is the most important factor influencing the success of root canal treatment (RCT. Working length (WL is the key element in achieving this. Aim: The aim of this study is to compare and evaluate the preoperative estimated WL with conventional radiograph and with grid radiograph, with reference to electronic apex locator (EAL in single-rooted teeth. Settings and Design: Thirty permanent anterior teeth with complete root formation indicated for RCT were included in this study. Materials and Methods: Conventional radiograph (Group 1 and conventional radiograph with external grid (Group 2 were made before access opening. WL with EAL (Group 3 was determined after access opening. Statistical Analysis: The statistical package for the social sciences (SPSS version 16.0 (SPSS Inc., Chicago, IL, USA was used to compare the WLs of three groups, and the statistical significance was considered to be P ≤ 0.05. ANOVA, post hoc test were made to measure the intergroup comparison, and Pearson correlation values were obtained. Results and Conclusion: The results of the study showed a higher correlation between grid WL and apex locator WL than conventional WL and apex locator WL. Preoperative metrics with radiographic grid along with the apex locator is a better measuring tool compared to the conventional radiographic WL in a single-rooted tooth.

  16. Stress analysis of pressure vessels

    International Nuclear Information System (INIS)

    Kim, B.K.; Song, D.H.; Son, K.H.; Kim, K.S.; Park, K.B.; Song, H.K.; So, J.Y.

    1979-01-01

    This interim report contains the results of the effort to establish the stress report preparation capability under the research project ''Stress analysis of pressure vessels.'' 1978 was the first year in this effort to lay the foundation through the acquisition of SAP V structural analysis code and a graphic terminal system for improved efficiency of using such code. Software programming work was developed in pre- and post processing, such as graphic presentation of input FEM mesh geometry and output deformation or mode shope patterns, which was proven to be useful when using the FEM computer code. Also, a scheme to apply fracture mechanics concept was developed in fatigue analysis of pressure vessels. (author)

  17. Combined radiographic and anthropological approaches to victim identification of partially decomposed or skeletal remains

    International Nuclear Information System (INIS)

    Leo, C.; O'Connor, J.E.; McNulty, J.P.

    2013-01-01

    Victim identification is the priority in any scenario involving the discovery of single or multiple human remains for both humanitarian and legal reasons. Such remains may be incomplete and in various stages of decomposition. In such scenarios radiography contributes to both primary and secondary methods of identification; the comparison of ante-mortem dental radiographs to post-mortem findings is a primary identification method whereas the analysis of post-mortem skeletal radiographs to help create a biological profile and identify other individuating features is a secondary method of identification. This review will introduce and explore aspects of victim identification with a focus on the anthropological and radiography-based virtual anthropology approaches to establishing a biological profile, identifying other individuating factors and ultimately restoring an individual's identity. It will highlight the potential contribution that radiography, and radiographers, can make to the identification process and contribute to increasing awareness amongst radiographers of the value of their professional role in such investigations

  18. The one-leg standing radiograph

    OpenAIRE

    Pinsornsak, P.; Naratrikun, K.; Kanitnate, S.; Sangkomkamhang, T.

    2016-01-01

    Objectives The purpose of this study was to compare the joint space width between one-leg and both-legs standing radiographs in order to diagnose a primary osteoarthritis of the knee. Methods Digital radiographs of 100 medial osteoarthritic knees in 50 patients were performed. The patients had undergone one-leg standing anteroposterior (AP) views by standing on the affected leg while a both-legs standing AP view was undertaken while standing on both legs. The severity of the osteoarthritis wa...

  19. Film holder for radiographing tubing

    International Nuclear Information System (INIS)

    Davis, E.V.; Foster, B.E.

    1976-01-01

    A film cassette is described which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro

  20. Film holder for radiographing tubing

    Science.gov (United States)

    Davis, Earl V.; Foster, Billy E.

    1976-01-01

    A film cassette is provided which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro.

  1. Analysis of pipe stress using CAESAR II code

    International Nuclear Information System (INIS)

    Sitandung, Y.B.; Bandriyana, B.

    2002-01-01

    Analysis of this piping stress with the purpose of knowing stress distribution piping system in order to determine pipe supports configuration. As an example of analysis, Gas Exchanger to Warm Separator Line was chosen with, input data was firstly prepared in a document, i.e. piping analysis specification that its content named as pipe characteristics, material properties, operation conditions, guide equipment's and so on. Analysis result such as stress, load, displacement and the use support type were verified based on requirements in the code, standard, and regularities were suitable with piping system condition analyzed. As the proof that piping system is in safety condition, it can be indicated from analysis results (actual loads) which still under allowable load. From the analysis steps that have been done CAESAR II code fulfill requirements to be used as a tool of piping stress analysis as well as nuclear and non nuclear installation piping system

  2. Orthodontic and dysfunctional abnormalities of stomatognatic apparatus: radiographic analysis of 204 subjects

    International Nuclear Information System (INIS)

    Scutellari, P.N.; Capurso, V.; Rotolo, R.; Calura, G.; Orzincolo, C.

    1990-01-01

    Two hundred and four subjects (86 males and 118 females), aged 8 to 35 years, with different types of malocclusion, underwent panoramic dental radiography and skull teleradiography. This study was aimed at investigating advantages and limitations of the two radiographic techniques, in view of their use as screening methods. On orthopan-tomography, inferior interincisive point, menthon (Me), and, bilaterally, gonion (Go) and condilion (Co), were localized so as to allow a model of the right and left jaws to be made. On teleradiography of the skull, in lateral view, Steiner's cephalometric analysis allowed skeletal classes to be evaluated according to ANB angle values. More-over, major postural parameters relative to the relationship between skull and cervical spine were analyzed: atlanto-occipital distance, cranio-vertebral angle, cervical lordosis, and hyoid triangle. Orthopan-tomography, though not a reproducible technique, can be considered as a valuable screening method for it allows right and left hemi-jaws to be comparatively measured. Cephalometric analysis of postural data confirmed the frequency of wrong postures in orthodontic patients. From the correlation of mandibular asymmetries and cranio-cervical parameters, the authors observed that asymmetrical patients have many postural problems, just like class II skeletal and dolico-facial types. This findings seems to confirm the mixed (functional and skeletal) etiopathogenesis of mandibular asymmetries

  3. Cost-effectiveness of barium enemas performed by radiographers

    International Nuclear Information System (INIS)

    Brown, Lorraine; Desai, Sharad

    2002-01-01

    AIM: To assess the cost-effectiveness of barium enemas performed by radiographers compared to those performed by consultant radiologists. METHOD: Prospective study of 200 barium enemas carried out by a senior radiographer and a consultant radiologist. The sample was a consecutive sample of adult out-patients over a 3-month period, with no exclusion. The length of time of the enema and the numbers and grades of staff involved in the procedure were recorded. This was translated into staffing costs using the appropriate pay scales. RESULTS: The barium enemas performed by the superintendent radiographer were more cost-effective than those performed by the consultant radiologist (1406 pounds for 100 radiographer-performed barium enemas compared to 1787 pounds for 100 carried out by the consultant radiologist). CONCLUSION: In terms of staffing costs, radiographers performing barium enemas not only liberates radiologist time, it is also a cost-effective method of providing an out-patient barium enema service. Brown, L. and Desai, S. (2002)

  4. Neutron radiographic findings in light water reactor fuel

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1979-06-01

    The assessment of neutron radiographs of nuclear fuel elements can be much easier, faster and simpler if reference can be made to typical defects, which can be revealed by neutron radiography. In other fields of industrial radiography collections of reference radiographs, showing typical defects in welding, or casting have been completed and published long ago. Since 1974 neutron radiography is routinely used at Risoe National Laboratory, Denmark, for the quality and performance control of nuclear fuel. About 2000 neutron radiographs were taken, mainly during the post irradiation examination of light water reactor fuel. During assessment of neutron radiographs some typical defects of the fuel were found and it was felt that a classification of such defects will help to speed up the assessment procedure. Therefore an attempt was made to establish such a classification, which is currently used at Risoe now. This classification is presented in this atlas, which contains 36 neutron radiographs reproduced on film (in original size) and on paper (twice enlarged). (author)

  5. Radiographers' performance in chest X-ray interpretation: the Nigerian experience

    Science.gov (United States)

    Egbe, N O; Akpan, B E

    2015-01-01

    Objective: To assess the performance of Nigerian radiographers in interpretation of plain chest radiographs and to assess whether age, years since qualification and sector of practice are associated with performance. Methods: A test set of 50 radiographs containing 23 cases with no pathology (normal) and 27 abnormal cases (cardiopulmonary conditions) independently confirmed by 3 radiologists were presented to 51 radiographers in a random order. Readers independently evaluated radiographs for absence or presence of disease and stated the location, radiographic features and diagnosis. Readers self-reported their age, years since qualification and sector of practice. Receiver operating characteristic was used to assess the performance. Mann–Whitney U test was used to assess whether age, years since qualification and sector of practice were associated with performance. Results: Mean location sensitivity was 88.9 [95% confidence interval (CI), 0.787–0.980]. Mean sensitivity and specificity were 76.9 (95% CI, 0.658–0.864) and 79.8 (95% CI, 0.658–0.864), respectively. Age was not associated with performance (p = 0.07). Number of years qualified as radiographer (p = 0.005) and private practice (p = 0.004) were positively associated with performance. Conclusion: Nigerian radiographers can correctly report chest radiographs to a reasonable standard, and performance is associated with number of years since qualification and the sector of practice. Advances in knowledge: There are less than 300 radiologists serving a Nigerian population of about 170 million; therefore, X-ray interpretation by radiographers deserves consideration. Nigerian radiographers have potential to interpret chest X-ray in the clinical setting, and this may significantly improve radiology service delivery in this region. PMID:25966290

  6. Stress Fractures of the Distal Femur Involving Small Nonossifying Fibromas in Young Athletes.

    Science.gov (United States)

    Robertson, Michael; Gilley, Jasen; Nicholas, Richard

    2016-11-01

    Small nonossifying fibromas (ie, fibrocortical defects) are incidental findings commonly seen on radiographs of young patients evaluated for extremity pain or sport-related trauma. Although pathological fractures have been reported in larger lesions, the subcentimeter, intracortical defects are not generally thought to predispose to pathological fractures. The authors report on 2 young athletes who presented with knee pain after initiating conditioning exercise programs (cross-training). Both were diagnosed with transverse metaphyseal stress fractures involving fibrous cortical defects of the distal femur. Initial radiographs were interpreted without evidence of fractures. However, subsequent magnetic resonance imaging was informative, suggesting that magnetic resonance imaging may have value in identifying potential stress reactions in young athletes. In addition, subsequent plain radiographs of both patients showed subperiosteal new bone formation in these nondisplaced fractures, suggesting that serial radiographs and close clinical follow-up are warranted for patients with persistent symptoms. The authors propose that, in the appropriate clinical setting, the presence of a small nonossifying fibroma may be a clinical indication that further evaluation is needed when plain radiographs show normal findings, as the defect could be an unrecognized area of fracture initiation. [Orthopedics. 2016; 39(6):e1197-e1200.]. Copyright 2016, SLACK Incorporated.

  7. Radiographic evaluation of the maxillary sinus prior to dental implant therapy: A comparison between two dimensional and three dimensional radiographic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tadinada, Aditya; Fung, Karen; Thacker, Sejal; Mahdian, Mina; Jadhaw, Aniket; Schincaglia, Gian Pietro [University of Connecticut School of Dental Medicine, Farmington (United States)

    2015-09-15

    This study was performed to evaluate the diagnostic efficacy of panoramic radiography and cone-beam computed tomography (CBCT) in detecting sinus pathology. This study was based on a retrospective evaluation of patients who had undergone both a panoramic radiograph and a CBCT exam. A total of 100 maxillary sinuses were evaluated. Four examiners with various levels of expertise evaluated the images using a five-point scoring system. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic efficacy of the two modalities. The image analysis was repeated twice, with at least two weeks between the evaluation sessions. Interobserver reliability was assessed using Cronbach's alpha, and intraobserver reliability was assessed using Cohen's kappa. Maxillary sinus pathology was detected in 72% of the patients. High interobserver and intraobserver reliability were observed for both imaging modalities and among the four examiners. Statistical analyses using ROC curves demonstrated that the CBCT images had a larger area under the curve (0.940) than the panoramic radiographs (0.579). Three-dimensional evaluation of the sinus with CBCT was significantly more reliable in detecting pathology than panoramic imaging.

  8. Radiographic arthrosis after elbow trauma: interobserver reliability.

    NARCIS (Netherlands)

    Lindenhovius, A.; Karanicolas, P.J.; Bhandari, M.; Ring, D.; Kampen, A. van; et al.,

    2012-01-01

    PURPOSE: This study measured observer variation in radiographic rating of elbow arthrosis. METHODS: Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint;

  9. Radiographic Arthrosis After Elbow Trauma: Interobserver Reliability

    NARCIS (Netherlands)

    Lindenhovius, Anneluuk; Karanicolas, Paul Jack; Bhandari, Mohit; Ring, David; Allan, Cristopher; Axelrod, Terry; Baratz, Mark; Beingessner, Daphne; Cassidy, Charles; Coles, Chad; Conflitti, Joe; Rocca, Gregory Della; van Dijk, C. Niek; Elmans, L. H. G. J.; Feibe, Roger; Frihagen, Frede; Gosens, Taco; Greenberg, Jeffrey; Grosso, Elena; Harness, Neil; van der Heide, Huub; Jeray, Kyle; Kalainov, David; van Kampen, Albert; Kawamura, Sumito; Kloen, Peter; McCormac, Bob; McKee, Michael; Page, Richard; Pesantez, Rodrigo; Peters, Anil; Petrisor, Brad; Poolman, Rudolf; Richardson, Martin; Seiler, John; Swiontkowski, Marc; Trumble, Thomas; Wright, Thomas; Zalavras, Charalampos; Zura, Robert

    2012-01-01

    Purpose This study measured observer variation in radiographic rating of elbow arthrosis. Methods Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint;

  10. Radiographic abnormalities in tricyclic acid overdose

    International Nuclear Information System (INIS)

    Varnell, R.M.; Richardson, M.L.; Vincent, J.M.; Godwin, J.D.

    1987-01-01

    Several case reports have described adult respiratory distress syndrome (ARDS) secondary to tricyclic acid (TCA) overdose. During a 1-year period 83 patients requiring intubation secondary to drug overdose were evaluated. Abnormalities on chest radiographs occurred in 26 (50%) of the 54 patients with TCA overdose, compared to six (21%) of the 29 patients overdosed with other drugs. In addition, five (9%) of the patients with TCA overdose subsequently had radiographic and clinical abnormalities meeting the criteria for ARDS. Only one (3%) of the patients with non-TCA overdose subsequently had change suggesting ARDS. TCAs should be added to the list of drugs associated with ARDS, and TCA overdose should be considered a major risk factor in the development of radiographically evident abnormalities

  11. Opportunistic esophagitis in AIDS: Radiographic diagnosis

    International Nuclear Information System (INIS)

    Levine, M.S.; Woldenberg, R.; Herlinger, H.; Laufer, I.

    1987-01-01

    Between 1983 and 1986, 35 of 90 patients with acquired immunodeficiency syndrome (AIDS) had double-contrast esophagograms to rule out opportunistic esophagitis. The radiographs were reviewed without knowledge of the clinical or endoscopic findings. Candida esophagitis was diagnosed radiographically in 17 patients who had varying degrees of plaque formation and viral esophagitis in three who had discrete ulcers without plaques. All three patients with viral esophagitis (herpes in 2 and cytomegalo virus in one) and 15 of 17 with Candida esophagitis had endoscopic and/or clinical corroboration of the radiographic diagnosis. Thus, the authors' experience suggests that fungal and viral esophagitis can often be differentiated on double-contrast esophagography, so that appropriate antifungal or antiviral therapy can be instituted without need for endoscopic intervention

  12. Pre-procedural scout radiographs are unnecessary for routine pediatric fluoroscopic examinations

    Energy Technology Data Exchange (ETDEWEB)

    Creeden, Sean G.; Rao, Anil G.; Eklund, Meryle J.; Hill, Jeanne G.; Thacker, Paul G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2017-03-15

    Although practice patterns vary, scout radiographs are often routinely performed with pediatric fluoroscopic studies. However few studies have evaluated their utility in routine pediatric fluoroscopy. To evaluate the value of scout abdomen radiographs in routine barium or water-soluble enema, upper gastrointestinal (GI) series, and voiding cystourethrogram pediatric fluoroscopic procedures. We retrospectively evaluated 723 barium or water-soluble enema, upper GI series, and voiding cystourethrogram fluoroscopic procedures performed at our institution. We assessed patient history and demographics, clinical indication for the examination, prior imaging findings and impressions, scout radiograph findings, additional findings provided by the scout radiograph that were previously unknown, and whether the scout radiograph contributed any findings that significantly changed management. We retrospectively evaluated 723 fluoroscopic studies (368 males and 355 females) in pediatric patients. Of these, 700 (96.8%) had a preliminary scout radiograph. Twenty-three (3.2%) had a same-day radiograph substituted as a scout radiograph. Preliminary scout abdomen radiographs/same-day radiographs showed no new significant findings in 719 (99.4%) studies. New but clinically insignificant findings were seen in 4 (0.6%) studies and included umbilical hernia, inguinal hernia and hip dysplasia. No findings were found on the scout radiographs that would either alter the examination performed or change management with regard to the exam. Pre-procedural scout abdomen radiographs are unnecessary in routine barium and water-soluble enema, upper GI series, and voiding cystourethrogram pediatric fluoroscopic procedures and can be substituted with a spot fluoroscopic last-image hold. (orig.)

  13. Radiographic features of appendiceal colic in children

    International Nuclear Information System (INIS)

    Schisgall, R.M.

    1986-01-01

    The concept of appendiceal colic was introduced in 1980 to explain the common problem of recurrent crampy abdominal pain (RAP) in children. Children with appendiceal colic often have inspissated casts of stool as foreign bodies of the appendix. The radiographic findings of 115 children operated upon for appendiceal colic have been reviewed. The radiographic features of this syndrom have included: filling defects of the appendix (83% incidence of inspissated casts of stool within the appendix); partial filling of the appendix (44% incidence of fecal casts); retained barium behind 72 h (92% incidence of fecal casts blocking egress of barium); non-visualization of the appendix (42% incidence of fecal casts); and distention of the appendix (100% incidence of fecal casts). The correlation of radiographic and operative findings will be presented. A rational approach to the radiographic workup of a child with RAP will be presented. (orig.)

  14. Digital radiographic evaluation of alveolar bone loss, density and lamina dura integrity on post splinting mandibular anterior with chronic periodontitis

    Science.gov (United States)

    Rafini, F.; Priaminiarti, M.; Sukardi, I.; Lessang, R.

    2017-08-01

    The healing of periodontal splinting can be detected both with clinical and radiographic examination. In this study, the alveolar bone was evaluated by radiographic digital periapical analysis. Periodontal tooth splinting is periodontal support therapy used to prevent periodontal injury during repair and regeneration of periodontal therapy. Radiographic digital periapical analysis of alveolar bone in the mandibular anterior region with chronic periodontitis and 2/3 cervical bone loss after three months of periodontal splinting. Eighty four proximal site (43 mesial and 41 distal) from 16 patients with chronic periodontitis and treated with spinting were examined by taking periapical digital radiographic at day 1 and 91. The bone loss, bone density and utility of lamina dura were evaluated. The statistical analysis after three months evaluation using T-test for bone loss, Wilcoxon sign rank test for bone density and utility lamina dura showed no significantly differences (pchronic periodontitis with 2/3 alveolar bone loss after three months splinting.

  15. Radiographic diagnoses and treatment decisions on approximal caries

    International Nuclear Information System (INIS)

    Espelid, I.

    1987-01-01

    Mineral loss which represents a threshold value for radiographic diagnosis, cannot be defined exactly. For clinical use 10% mineral loss in the direction of the X-ray beam may constitute a border line lesion for radiographic detection, and caries lesions without cavitation seemed to be beyond this diagnostic threshold. The degree of caries estimated by using radiographs is fairly closely related to the depth of the tissue changes recorded in the prepared cavity. Radiographic examinations more often lead to underestimation than overestimation of the degree of caries. Radiographic caries diagnoses made at different degrees of penetration toward the pulp showed insignificant variations with respect to quality, but the observers were more confident of caries being present (used more strict criterion) when they scored caries in inner dentin. Consensus on diagnostic criteria and improved diagnostic quality are considerably more important to the quality of therapeutic decisions on approximal caries than viewing conditions and film density. A semi-radiopaque material in Class II fillings seems to offer advantages compared to amalgam in respect of the diagnosis of secondary caries and marginal defects. There is a danger that dentists will restore approximal caries lesions too early and before these can be diagnosed in dentin radiographically

  16. Definitive radiotherapy for head-and-neck cancer with radiographically positive retropharyngeal nodes: Incomplete radiographic response does not necessarily indicate failure

    International Nuclear Information System (INIS)

    Liauw, Stanley L.; Mancuso, Anthony A.; Morris, Christopher G. M.S.; Amdur, Robert J.; Mendenhall, William M.

    2006-01-01

    Purpose: Our aim was to report the control rate of radiographically positive retropharyngeal (RP) nodes with radiation therapy (RT) and to correlate posttreatment imaging with clinical outcome. Methods and Materials: Sixteen patients treated with definitive RT for head-and-neck cancer had radiographically positive RP nodes (size >1 cm in largest axial dimension, or presence of focal enhancement, lucency, or calcification), and both pre-RT and post-RT image sets available for review. An additional 21 patients with unconfirmed radiographically positive RP nodes had post-RT imaging, which consisted of computed tomography (CT) at a median of 4 weeks after completing RT. Patients with positive post-RT RP nodes underwent observation with serial imaging. Results: Of 16 patients with pre-RT and post-RT images available for review, 9 (56%) had a radiographic complete response, and of 21 patients with unconfirmed positive RP nodes with post-RT images available for review, 14 (67%) had a radiographic complete response. In all, 14 patients with incomplete response on post-RT imaging experienced control of their disease with no further therapy, and no RP node or neck failures were noted during a median follow-up of 2.8 years. Six patients with positive post-RT RP nodes had serial imaging available for review, and none demonstrated radiographic progression of disease. Conclusions: Radiographic response at 4 weeks may not accurately reflect long-term locoregional control, as RP nodes may continue to resolve over time. The highest index of suspicion should be reserved for patients with progressive changes in size, focal lucency, or focal enhancement on serial imaging after RT

  17. Three-dimensional reconstruction of the human spine from bi-planar radiographs: using multiscale wavelet analysis and spline interpolators for semi-automation

    Science.gov (United States)

    Deschenes, Sylvain; Godbout, Benoit; Branchaud, Dominic; Mitton, David; Pomero, Vincent; Bleau, Andre; Skalli, Wafa; de Guise, Jacques A.

    2003-05-01

    We propose a new fast stereoradiographic 3D reconstruction method for the spine. User input is limited to few points passing through the spine on two radiographs and two line segments representing the end plates of the limiting vertebrae. A 3D spline that hints the positions of the vertebrae in space is then generated. We then use wavelet multi-scale analysis (WMSA) to automatically localize specific features in both lateral and frontal radiographs. The WMSA gives an elegant spectral investigation that leads to gradient generation and edge extraction. Analysis of the information contained at several scales leads to the detection of 1) two curves enclosing the vertebral bodies' walls and 2) inter-vertebral spaces along the spine. From this data, we extract four points per vertebra per view, corresponding to the corners of the vertebral bodies. These points delimit a hexahedron in space where we can match the vertebral body. This hexahedron is then passed through a 3D statistical database built using local and global information generated from a bank of normal and scoliotic spines. Finally, models of the vertebrae are positioned with respect to these landmarks, completing the 3D reconstruction.

  18. Digitization of radiographic inspection for pipeline girth welded joints

    International Nuclear Information System (INIS)

    Uemura, Shimpei

    2016-01-01

    In radiographic inspection for the girth welded joints of natural gas pipeline, film radiographic testing (FRT) is applied presently in Japan. However, as of July 2016, the work of establishing JIS standard for radiographic inspection with digital detector is in progress. In order to provide users with the merit of digitization as soon as possible, the authors have developed NSDART (Nittetsu-Sumikin digital detector array technology) as a field X-ray inspection system for the girth welded joints of pipeline. This paper reports the required performances discussed in face of development of NSDART, selection of digital detector, and outline of NSDART, and shows part of the radiographic images acquired with NSDART. As required performances, the following were established: (1) required image quality for radiographic image, (2) identifiable minimum wire diameter of transmission meter, (3) density range of radiographic image and value of gradation meter, (4) spatial resolution via Duplex Wire, (5) X-ray generator, (6) real time performance, and (7) display for observing radiographic image. As for the selection of digital detector, flat panel detector was judged to be the most suitable, and its incorporation to NSDART was determined. NSDART devices are composed of a magnet-wheeled self-propelled imaging device, personal computer, controller, and externally installed display for judgment. (A.O.)

  19. Fragile X syndrome: panoramic radiographic evaluation of dental anomalies, dental mineralization stage, and mandibular angle.

    Science.gov (United States)

    Sabbagh-Haddad, Aida; Haddad, Denise Sabbagh; Michel-Crosato, Edgard; Arita, Emiko Saito

    2016-01-01

    The purpose of this study was to evaluate the dental radiographic characteristics as described in 40 records of patients with panoramic radiography. The patients were in the range of 6-17 years old, and were divided into two groups (20 subjects who were compatible with the normality standard and 20 individuals diagnosed with the FXS), which were matched for gender and age. Analysis of the panoramic radiographic examination involved the evaluation of dental mineralization stage, mandibular angle size, and presence of dental anomalies in both deciduous and permanent dentitions. The results of radiographic evaluation demonstrated that the chronology of tooth eruption of all third and second lower molars is anticipated in individuals with FXS (pdental anomalies. In addition, an increase was observed in the mandibular angle size in the FXS group (pdental radiographic changes is of great importance for dental surgeons to plan the treatment of these individuals.

  20. Stress analysis of shear/compression test

    International Nuclear Information System (INIS)

    Nishijima, S.; Okada, T.; Ueno, S.

    1997-01-01

    Stress analysis has been made on the glass fiber reinforced plastics (GFRP) subjected to the combined shear and compression stresses by means of finite element method. The two types of experimental set up were analyzed, that is parallel and series method where the specimen were compressed by tilted jigs which enable to apply the combined stresses, to the specimen. Modified Tsai-Hill criterion was employed to judge the failure under the combined stresses that is the shear strength under the compressive stress. The different failure envelopes were obtained between the two set ups. In the parallel system the shear strength once increased with compressive stress then decreased. On the contrary in the series system the shear strength decreased monotonicly with compressive stress. The difference is caused by the different stress distribution due to the different constraint conditions. The basic parameters which control the failure under the combined stresses will be discussed

  1. Commitment of the radiographer - does it matter to the patient?

    International Nuclear Information System (INIS)

    Blagoeva, D.; Shuleva, L.; Goudeva, V.; Stoinova, V.

    2015-01-01

    Full text: Radiographers are responsible for providing safe and accurate imaging examinations in a wide range of clinical environments, using a variety of imaging modalities and techniques so that appropriate management and treatment of patients and clients can proceed. The purpose of this presentation is to discuss: the responsibilities of radiographer in the clinical radiology department; their professional judgment to decide how to achieve a diagnostic outcome; the relationship patient/radiographer; the impact of the radiographer on patient care. Patient care and advocacy has always been an integral part of the radiography profession. The radiographer should respect the patient at all the times, be genuine in nature and empathies with the patient‘s condition. Good listening and observational skills are also very important components. The radiographers are personally accountable for their work and professional conduct

  2. Chest Radiographic Findings in Newly Diagnosed Pulmonary ...

    African Journals Online (AJOL)

    Five hundred newly diagnosed cases of Pulmonary Tuberculosis were treated with directly observed short-course treatment and 100 of them had chest radiographic examination done. The various chest radiographic patterns in the 100 subjects were studied and included: Fluffy exudative changes 80(80%), fibrosis 70(70%) ...

  3. The utility of plain radiographs in the initial evaluation of knee pain amongst sports medicine patients.

    Science.gov (United States)

    Alaia, Michael J; Khatib, Omar; Shah, Mehul; A Bosco, Joseph; M Jazrawi, Laith; Strauss, Eric J

    2015-08-01

    To evaluate whether screening radiographs as part of the initial workup of knee pain impacts clinical decision-making in a sports medicine practice. A questionnaire was completed by the attending orthopaedic surgeon following the initial office visit for 499 consecutive patients presenting to the sports medicine centre with a chief complaint of knee pain. The questionnaire documented patient age, duration of symptoms, location of knee pain, associated mechanical symptoms, history of trauma within the past 2 weeks, positive findings on plain radiographs, whether magnetic resonance imaging was ordered, and whether plain radiographs impacted the management decisions for the patient. Patients were excluded if they had prior X-rays, history of malignancy, ongoing pregnancy, constitutional symptoms as well as those patients with prior knee surgery or intra-articular infections. Statistical analyses were then performed to determine which factors were more likely do correspond with diagnostic radiographs. Overall, initial screening radiographs did not change management in 72 % of the patients assessed in the office. The mean age of patients in whom radiographs did change management was 57.9 years compared to 37.1 years in those patients where plain radiograph did not change management (p < 0.0001). Plain radiographs had no impact on clinical management in 97.3 % of patients younger than 40. In patients whom radiographs did change management, radiographs were more likely to influence management if patients were over age forty, had pain for over 6 months, had medial or diffuse pain, or had mechanical symptoms. A basic cost analysis revealed that the cost of a clinically useful radiographic series in a patient under 40 years of age was $7,600, in contrast to $413 for a useful series in patients above the age of 40. Data from the current study support the hypothesis that for the younger patient population, routine radiographic imaging as a screening tool may be of

  4. Meaning contents of radiographers' professional identity as illustrated in a professional journal - A discourse analytical approach

    International Nuclear Information System (INIS)

    Niemi, Antti; Paasivaara, Leena

    2007-01-01

    Aim: The purpose of the present study is to describe and understand the meaning contents of radiographers' professional identity. Background: The conceptualisation of professional identity in terms of radiographers' perceptions of their role focuses on their preferred role-content and perception of the professional self. Professional identity defines values and beliefs that guide the radiographer's thinking, actions and interaction. Method: The present study employs the method of discourse analysis to gain a profound understanding of the cultural meaning contents related to the formation of the professional identity of radiographers. Material for the study was gathered from articles published in the professional journal of the Society of Radiographers in Finland between the years 1987 and 2003. Findings: Technical discourse emphasised the importance of responding to the changes in radiology in the 1990s. Safety discourse emerged as the second content of meaning describing the formation of professional identity. The third content of meaning in professional identity was professional discourse, a central aspect being to promote the esteem of one's profession and emphasise professional identity. Conclusions: The results suggest that the professional identity of a radiographer is dual in nature. On one hand, the professional identity of a radiographer is based on solid command of scientific-mechanic technology in a technical working environment; while on the other hand, it consists of mastering the humane, humanistic nursing work

  5. Radiographic features of bisphosphonate therapy in pediatric patients

    Energy Technology Data Exchange (ETDEWEB)

    Grissom, L.E.; Theodore Harcke, H. [Dept. of Medical Imaging, Alfred I. duPont Hospital for Children, Nemours Children' s Clinic, Wilmington, DE (United States)

    2003-04-01

    Background: Pediatric patients are being treated with bisphosphonates for low bone mineral density. Skeletal radiographic findings have been described with bisphosphonates given orally and intravenously. Objective: To determine and describe the radiographic findings of cyclic intravenous bisphosphonate therapy in the growing skeleton. Materials and methods: Retrospective review of radiographs of 32 patients with osteogenesis imperfecta or cerebral palsy treated with intravenous bisphosphonates on a quarterly schedule. Results: Principal observations were metaphyseal bands and increased bone mineral density. The bands varied in spacing according to the age of the patient, rate of growth, and the location of the metaphysis. Fractures continued to be seen in patients with osteogenesis imperfecta. Conclusion: Cyclic bisphosphonate therapy results in distinctive radiographic findings in the growing skeleton. (orig.)

  6. Radiographic features of bisphosphonate therapy in pediatric patients

    International Nuclear Information System (INIS)

    Grissom, L.E.; Theodore Harcke, H.

    2003-01-01

    Background: Pediatric patients are being treated with bisphosphonates for low bone mineral density. Skeletal radiographic findings have been described with bisphosphonates given orally and intravenously. Objective: To determine and describe the radiographic findings of cyclic intravenous bisphosphonate therapy in the growing skeleton. Materials and methods: Retrospective review of radiographs of 32 patients with osteogenesis imperfecta or cerebral palsy treated with intravenous bisphosphonates on a quarterly schedule. Results: Principal observations were metaphyseal bands and increased bone mineral density. The bands varied in spacing according to the age of the patient, rate of growth, and the location of the metaphysis. Fractures continued to be seen in patients with osteogenesis imperfecta. Conclusion: Cyclic bisphosphonate therapy results in distinctive radiographic findings in the growing skeleton. (orig.)

  7. Stress analysis of a rupture disk

    International Nuclear Information System (INIS)

    Werne, R.W.

    1975-04-01

    The results of an elastic stress analysis of the rupture disk for an internal pressure of 45.5 MPa (6600 psi) indicate that the maximum von Mises stresses occur in the membrane and are on the order of 483 to 690 MPa (70,000 psi). This far exceeds the yield of the membrane material of 207 MPa (30,000 psi). These high stresses are expected since the membrane is designed to burst at that design pressure. The von Mises stresses in the rest of the body are less than 138 MPa (20,000 psi). An elastic-plastic analysis of the membrane alone subjected to the 45.5 MPa (6600 psi) pressure indicates that it becomes plastically unstable, i.e., it continues to deform under constant load. A second load case with a constant 6.9 MPa (1000 psi) pressure throughout the entire body (i.e., after release of pressure by burst of the membrane) was analyzed. The results indicate that the elastic von Mises stresses are less than 26.7 MPa (3880 psi) throughout the body. (U.S.)

  8. Childhood optic chiasm gliomas: radiographic response following radiotherapy and long-term clinical outcome

    International Nuclear Information System (INIS)

    Tao, May L.; Barnes, Patrick D.; Billett, Amy L.; Leong, Traci; Shrieve, Dennis C.; Scott, R. Michael; Tarbell, Nancy J.

    1997-01-01

    Purpose: In children with chiasmal gliomas, radiation therapy can arrest progressive visual and neurologic impairment. We examined the radiographic response and clinical outcomes after irradiation. Methods and Materials: Forty-two children (median age at diagnosis, 6.6 years) with chiasmal gliomas were managed as follows: 11 asymptomatic patients with neurofibromatosis-1 (NF-1) were observed only; 2 patients, less than 3 years old, underwent surgery and chemotherapy to delay irradiation; and 29 patients with progressive disease received radiation with or without prior surgery or chemotherapy. Time to radiographic response, long-term tumor control and late sequelae were reviewed for the 29 irradiated patients. Results: The probability of at least 50% radiographic response at 24 months after irradiation was 18.1% and increased to 38.2% by 48 months and 45.9% by 60 months. By actuarial analysis, the median time for such radiographic response was 62 months. For the 29 irradiated patients, the 10-year freedom from progression and overall survival rates were 100% and 89%, respectively (median follow-up for surviving patients, 108 months). Stabilization or improvement in vision occurred in 81% of 26 evaluable irradiated patients. Conclusions: Notable radiographic response may be observed years after irradiation. Radiation therapy provides excellent long-term tumor control and vision preservation or improvement in the majority of patients with progressive chiasmal gliomas

  9. Methods of silver recovery from radiographs - comparative study

    Science.gov (United States)

    Canda, L. R.; Ardelean, E.; Hepuţ, T.

    2018-01-01

    Management and recovery of waste are activities with multiple impacts: technologically (by using waste on current production flows, thus replacing poor raw materials), economically (can substantially reduce manufacturing costs by recycling waste), social (by creating new jobs where it is necessary to process the waste in a form more suited to technological flows) and ecologically (by removing waste that is currently produced or already stored - but poses a threat to the health of the population and / or to the environment). This is also the case for medical waste, for example radiographs, which are currently produced in large quantities, for which replacement solutions are sought, but are currently stored by archiving in hospital units. The paper presents two methods used for this kind of waste management, the result being the recovery of silver, material with applications and with increasing price, but also the proper disposal of the polymeric support. This analysis aims at developing a more efficient recycling technology for medical radiographs.

  10. Equipment for fully automatic radiographic pipe inspection

    International Nuclear Information System (INIS)

    Basler, G.; Sperl, H.; Weinschenk, K.

    1977-01-01

    The patent describes a device for fully automatic radiographic testing of large pipes with longitudinal welds. Furthermore the invention enables automatic marking of films in radiographic inspection with regard to a ticketing of the test piece and of that part of it where testing took place. (RW) [de

  11. Reestablishment of radiographic kidney size in Miniature Schnauzer dogs.

    Science.gov (United States)

    Sohn, Jungmin; Yun, Sookyung; Lee, Jeosoon; Chang, Dongwoo; Choi, Mincheol; Yoon, Junghee

    2017-01-10

    Kidney size may be altered in renal diseases, and the detection of kidney size alteration has diagnostic and prognostic values. We hypothesized that radiographic kidney size, the kidney length to the second lumbar vertebra (L2) length ratio, in normal Miniature Schnauzer dogs may be overestimated due to their shorter vertebral length. This study was conducted to evaluate radiographic and ultrasonographic kidney size and L2 length in clinically normal Miniature Schnauzers and other dog breeds to evaluate the effect of vertebral length on radiographic kidney size and to reestablish radiographic kidney size in normal Miniature Schnauzers. Abdominal radiographs and ultrasonograms from 49 Miniature Schnauzers and 54 other breeds without clinical evidence of renal disease and lumbar vertebral abnormality were retrospectively evaluated. Radiographic kidney size, in the Miniature Schnauzer (3.31 ± 0.26) was significantly larger than that in other breeds (2.94 ± 0.27). Relative L2 length, the L2 length to width ratio, in the Miniature Schnauzer (1.11 ± 0.06) was significantly shorter than that in other breeds (1.21 ± 0.09). However, ultrasonographic kidney sizes, kidney length to aorta diameter ratios, were within or very close to normal range both in the Miniature Schnauzer (6.75 ± 0.67) and other breeds (7.16 ± 1.01). Thus, Miniature Schnauzer dogs have breed-specific short vertebrae and consequently a larger radiographic kidney size, which was greater than standard reference in normal adult dogs. Care should be taken when evaluating radiographic kidney size in Miniature Schnauzers to prevent falsely diagnosed renomegaly.

  12. CT colonography: accuracy of initial interpretation by radiographers in routine clinical practice

    International Nuclear Information System (INIS)

    Burling, D.; Wylie, P.; Gupta, A.; Illangovan, R.; Muckian, J.; Ahmad, R.; Marshall, M.; Taylor, S.A.

    2010-01-01

    Aim: To investigate performance of computed-assisted detection (CAD)-assisted radiographers interpreting computed tomography colonography (CTC) in routine practice. Materials and methods: Three hundred and three consecutive symptomatic patients underwent CTC. Examinations were double-read by trained radiographers using primary two-dimensional/three-dimensional (2D/3D) analysis supplemented by 'second reader' CAD. Radiographers recorded colonic neoplasia, interpretation times, and patient management strategy code (S0, inadequate; S1, normal; S2, 6-9 mm polyp; S3, ≥10 mm polyp; S4, cancer; S5, diverticular stricture) for each examination. Strategies were compared to the reference standard using kappa statistic, interpretation times using paired t-test, learning curves using logistic regression and Pearson's correlation coefficient. Results: Of 303 examinations, 69 (23%) were abnormal. CAD-assisted radiographers detected 17/17 (100%) cancers, 21/28 (72%) polyps ≥10 mm and 42/60 (70%) 6-9 mm polyps. The overall agreement between radiographers and the reference management strategy was good (kappa 0.72; CI: 0.65, 0.78) with agreement for S1 strategy in 189/211 (90%) exams; S2 in 19/27 (70%); S3 in 12/19 (63%); S4 in 17/17 (100%); S5 in 5/6 (83%). The mean interpretation time was 17 min (SD = 11) compared with 8 min (SD = 3.5) for radiologists. There was no learning curve for recording correct strategies (OR 0.88; p = 0.12) but a significant reduction in interpretation times, mean 14 and 31 min (last/first 50 exams; -0.46; p < 0.001). Conclusion: Routine CTC interpretation by radiographers is effective for initial triage of patients with cancer, but independent reporting is currently not recommended.

  13. Detection of proximal caries using digital radiographic systems with different resolutions.

    Science.gov (United States)

    Nikneshan, Sima; Abbas, Fatemeh Mashhadi; Sabbagh, Sedigheh

    2015-01-01

    Dental radiography is an important tool for detection of caries and digital radiography is the latest advancement in this regard. Spatial resolution is a characteristic of digital receptors used for describing the quality of images. This study was aimed to compare the diagnostic accuracy of two digital radiographic systems with three different resolutions for detection of noncavitated proximal caries. Diagnostic accuracy. Seventy premolar teeth were mounted in 14 gypsum blocks. Digora; Optime and RVG Access were used for obtaining digital radiographs. Six observers evaluated the proximal surfaces in radiographs for each resolution in order to determine the depth of caries based on a 4-point scale. The teeth were then histologically sectioned, and the results of histologic analysis were considered as the gold standard. Data were entered using SPSS version 18 software and the Kruskal-Wallis test was used for data analysis. P detection of proximal caries (P > 0.05). RVG access system had the highest specificity (87.7%) and Digora; Optime at high resolution had the lowest specificity (84.2%). Furthermore, Digora; Optime had higher sensitivity for detection of caries exceeding outer half of enamel. Judgment of oral radiologists for detection of the depth of caries had higher reliability than that of restorative dentistry specialists. The three resolutions of Digora; Optime and RVG access had similar accuracy in detection of noncavitated proximal caries.

  14. Matching hand radiographs

    NARCIS (Netherlands)

    Kauffman, J.A.; Slump, Cornelis H.; Bernelot Moens, H.J.

    2005-01-01

    Biometric verification and identification methods of medical images can be used to find possible inconsistencies in patient records. Such methods may also be useful for forensic research. In this work we present a method for identifying patients by their hand radiographs. We use active appearance

  15. Effects of Different Viewing Conditions on Radiographic Interpretation

    Directory of Open Access Journals (Sweden)

    Mahkameh Moshfeghi

    2016-08-01

    Full Text Available Objectives: Optimum viewing conditions facilitate identification of radiographic details and decrease the need for retakes, patients’ costs and radiation dose. This study sought to evaluate the effects of different viewing conditions on radiographic interpretation.Materials and Methods: This diagnostic study was performed by evaluating radiograph of a 7mm-thick aluminum block, in which 10 holes with 2mm diameters were randomly drilled with depths ranging from 0.05 mm to 0.50mm. The radiograph was viewed by four oral radiologists independently under four viewing conditions, including a white light viewing light box in a lit room, yellow light viewing light box in a lit room, white light viewing light box in a dark room and yellow light viewing light box in a dark room. Number of circular shadows observed on the film was recorded. The data were analyzed by two-way ANOVA.Results: The mean number of detected circular shadows was 6.75, 7.5, 7.25 and 7.75 in white light viewing light box in a lit room, white light viewing light box in a dark room, yellow light viewing light box in a lit room and yellow light viewing light box in a dark room, respectively. Although the surrounding illumination had statistically significant effect on the radiographic details (P≤0.03, the light color of the viewing light box had no significant effect on visibility of the radiographic details.Conclusion: White and yellow light of the viewing light box had no significant effect on visibility of the radiographic details but more information was obtained in a dark room.

  16. Dental Radiographs Ordered by Dental Professionals: an ...

    African Journals Online (AJOL)

    Conclusions: Even in resource limited settings dental caries is still the regular indication for taking dental radiographs, and periapical views are the most frequent type of radiograph ordered. Maxillary central incisors and mandibular molars were types of teeth commonly x-rayed mainly due to the aesthetic importance of the ...

  17. Pattern analysis of planning and management at the radiographic dept. in hospital

    International Nuclear Information System (INIS)

    Yanagisawa, Makoto; Taniguchi, Gen; Imai, Shoji.

    1980-01-01

    We made 'typical working models' from the survey of 3 hospitals. The models can express staffs' movements that are variable as management types. We adapted these models to some planning types those are made from typical layouts, and evaluated the planning types of the radiographic dept. in hospital. The result of evaluation are as follows. (1) A-1, B-1 type; the contacts between staffs and patients are done well, but that is difficult to keep sterilized materials clean. These types are useful to the specific treatment zones. (2) B-3 type; this planning type is designed for staffs' movements of each room to be independent from other. This aim is well reflected in the result. But we must point out that so to speak assistant staffs', porters' or messengers' works are very hard. (3) C-1, D-1 type; staffs' zone and patients' are clearly separated in these types. So the staffs hardly pass through radiographic rooms to contact with patients. (4) D-2 type; this type, improved from B-1 type, is not seen in hospitals as ever. But this type can adopt almost any management type and be evaluated well in the result. (author)

  18. Comparative analysis between radiographic views for knee osteoarthrosis (bipedal AP versus monopedal AP

    Directory of Open Access Journals (Sweden)

    Rodrigo Pires e Albuquerque

    2013-08-01

    Full Text Available OBJECTIVE: A comparative analysis by applying the criteria of the original classification Ahlbäck in the anteroposterior (AP bipedal knee in extension and anteroposterior (AP monopodal knee in symptomatic knee arthrosis. With this analysis we intend to observe the agreement, any advantage or difference between the incidence and degree of joint involvement between the orthopedic surgeons and radiologists with the referring physician. METHODS: From January 2012 to March 2012, was a prospective study of 60 symptomatic arthrosis knees (60 patients, clinically selected group of outpatient knee and radiographic proposals submitted to the search. Of the 60 patients, 39 were female and 21 male, mean age 64 years (ranging from 50 to 84 years. Of the 60 knees studied, 37 corresponded to the right side and 23 on the left side. Statistical analysis was performed by Kappa statistics, which evaluates the interobserver agreement for qualitative data. RESULTS: According to the scale of Ahlbäck, there was a significant agreement (p < 0.0001 intra-observer in the classification of knee osteoarthritis among the five evaluators. There was a significant agreement (p < 0.0001 with inter-observer referring physician in the incidence of AP monopodal and AP bipedal for the four raters. CONCLUSION: The study found no difference between the incidence in the AP monopodal versus AP bipedal in osteoarthritis of the knee.

  19. Chest radiographic findings of tuberculous pneumonia

    International Nuclear Information System (INIS)

    Jung, Seung Hye; Sung, Dong Wook; Yoon, Yup; Lim, Jae Hoon

    1991-01-01

    When tuberculous pneumonia appears as a segmental or loabr consolidation, its is difficult to differentiate tuberculous pneumonia from nontuberculous bacterial pneumonia radiologically. The object of this study was to define the typical radiographic findings of tuberculous pneumonia through comparative analysis of tuberculous and nontuberculous pneumonia. A review of chest radiolograph in 29 patients with tuberculous pneumonia and in 23 patients with nontuberculous bacterial pneumonia was made with regard to homogeneity, volume loss, air-fluid level within the cavities, air-bronchogram, pleural disease, and predilection sites. The characteristic findings of tuberculous pneumonia are a heterogeneous density of infiltration (66%), evidence of volume loss of infiltrative lesion (52%), and cavity formation (48%) without air - fluid level. An associated parameter of analysis is the relative absence of leukocytosis (76%)

  20. Three-dimensional orientation and location-dependent varying rules of radiographic angles of the acetabular cup.

    Science.gov (United States)

    Zhao, Jing-Xin; Su, Xiu-Yun; Zhao, Zhe; Xiao, Ruo-Xiu; Zhang, Li-Cheng; Tang, Pei-Fu

    2018-02-17

    The aim of this study is to demonstrate the varying rules of radiographic angles following varying three-dimensional (3D) orientations and locations of cup using an accurate mathematical model. A cone model is established to address the quantitative relationship between the opening circle of cup and its ellipse projection on radiograph. The varying rules of two-dimensional (2D) radiographic anteversion (RA) and inclination (RI) angles can be analyzed. When the centre of cup is located above X-ray source, with proper 3D RI/RA angles, 2D RA angle can be equal to its 3D counterpart, and 2D RI angle is usually greater than its 3D counterpart. Except for the original point on hip-centered anterior-posterior radiograph, there is no area on radiograph where both 2D RA and RI angles are equal to their 3D counterparts simultaneously. This study proposes an innovative model for accurately explaining how 2D RA/RI angles of cup are varying following different 3D RA/RI angles and location of cup. The analysis results provide clinicians an intuitive grasp of knowledge about 2D RA/RI angles greater or smaller than their 3D counterparts post-operatively. The established model may allow determining the effects of pelvic rotations on 2D radiographic angles of cup.

  1. Proximal tibial stress fracture associated with mild osteoarthritis of the knee: case report.

    Science.gov (United States)

    Curković, Marko; Kovac, Kristina; Curković, Bozidar; Babić-Naglić, Durda; Potocki, Kristina

    2011-03-01

    Stress fractures are considered as multifactorial overuse injuries occurring in 0.3%-0.8% of patients suffering from rheumatic diseases, with rheumatoid arthritis being the most common underlying condition. Stress fractures can be classified according to the condition of the bone affected as: 1) fatigue stress fractures occurring when normal bone is exposed to repeated abnormal stresses; and 2) insufficiency stress fractures that occur when normal stress is applied to bone weakened by an underlying condition. Stress fractures are rarely associated with severe forms of knee osteoarthritis, accompanied with malalignment and obesity. We present a patient with a proximal tibial stress fracture associated with mild knee osteoarthritis without associated malalignment or obesity. Stress fracture should be considered when a patient with osteoarthritis presents with sudden deterioration, severe localized tenderness to palpation and localized swelling or periosteal thickening at the pain site and elevated local temperature. The diagnosis of stress fractures in patients with rheumatic diseases may often be delayed because plain film radiographs may not reveal a stress fracture soon after the symptom onset; moreover, evidence of a fracture may never appear on plain radiographs. Triple phase nuclear bone scans and magnetic resonance imaging are more sensitive in the early clinical course than plain films for initial diagnosis.

  2. Development and assessment of an e-learning course on breast imaging for radiographers: a stratified randomized controlled trial.

    Science.gov (United States)

    Moreira, Inês C; Ventura, Sandra Rua; Ramos, Isabel; Rodrigues, Pedro Pereira

    2015-01-05

    Mammography is considered the best imaging technique for breast cancer screening, and the radiographer plays an important role in its performance. Therefore, continuing education is critical to improving the performance of these professionals and thus providing better health care services. Our goal was to develop an e-learning course on breast imaging for radiographers, assessing its efficacy, effectiveness, and user satisfaction. A stratified randomized controlled trial was performed with radiographers and radiology students who already had mammography training, using pre- and post-knowledge tests, and satisfaction questionnaires. The primary outcome was the improvement in test results (percentage of correct answers), using intention-to-treat and per-protocol analysis. A total of 54 participants were assigned to the intervention (20 students plus 34 radiographers) with 53 controls (19+34). The intervention was completed by 40 participants (11+29), with 4 (2+2) discontinued interventions, and 10 (7+3) lost to follow-up. Differences in the primary outcome were found between intervention and control: 21 versus 4 percentage points (pp), Peffect in radiographers (23 pp vs 4 pp; P=.004) but was unclear in students (18 pp vs 5 pp; P=.098). Nonetheless, differences in students' posttest results were found (88% vs 63%; P=.003), which were absent in pretest (63% vs 63%; P=.106). The per-protocol analysis showed a higher effect (26 pp vs 2 pp; Pe-learning course is effective, especially for radiographers, which highlights the need for continuing education.

  3. Use your good judgement - Radiographers' knowledge in image production work

    International Nuclear Information System (INIS)

    Larsson, W.; Lundberg, N.; Hillergard, K.

    2009-01-01

    It has been shown that the demand for radiography services has markedly increased and radiographers' work has become more complex as their role has changed. More specifically, it entails new activities, new ways of communicating and new responsibilities. This means that radiographers work in new ways and need new ways to learn. The knowledge needed in this learning process is still unexplored. The aim of this study is to identify and present how radiographers use knowledge in image production work using PACS. This is explored by studying how radiographers use their knowledge in practice. The study adopts a qualitative approach, using participant observation of and semi-structured interviews with radiographers at five Swedish hospitals. To identify properties of knowledge, Blackler's theory of knowledge components was applied. The results of this study show that radiographers use the knowledge components in different situations in their image production work. They use embrained knowledge in planning X-ray examinations and in viewing images. Encoded knowledge is required for the use of various kinds of documentation, such as manuals and protocols. Embodied knowledge is action-oriented and involves 'gut feelings'. The study also illustrates that radiographers use their knowledge at different levels as routine actors or as reflective actors, in a more static way or with a flexible attitude, more unreflectively or more as critical reflectors, and finally more as performing automatic action or problem-solving action. This study concludes that radiographers need more reflective actors in the image production process when working with PACS. The study also illustrates that radiographers need to be flexible in their work; there is little room for static work. In work they need to analyze images, it is not enough to 'check them off'; they cannot just read documents, you need to interpret them to optimize work performance. Overall, radiographers need to have a critical and

  4. Pneumothorax detection in chest radiographs using local and global texture signatures

    Science.gov (United States)

    Geva, Ofer; Zimmerman-Moreno, Gali; Lieberman, Sivan; Konen, Eli; Greenspan, Hayit

    2015-03-01

    A novel framework for automatic detection of pneumothorax abnormality in chest radiographs is presented. The suggested method is based on a texture analysis approach combined with supervised learning techniques. The proposed framework consists of two main steps: at first, a texture analysis process is performed for detection of local abnormalities. Labeled image patches are extracted in the texture analysis procedure following which local analysis values are incorporated into a novel global image representation. The global representation is used for training and detection of the abnormality at the image level. The presented global representation is designed based on the distinctive shape of the lung, taking into account the characteristics of typical pneumothorax abnormalities. A supervised learning process was performed on both the local and global data, leading to trained detection system. The system was tested on a dataset of 108 upright chest radiographs. Several state of the art texture feature sets were experimented with (Local Binary Patterns, Maximum Response filters). The optimal configuration yielded sensitivity of 81% with specificity of 87%. The results of the evaluation are promising, establishing the current framework as a basis for additional improvements and extensions.

  5. A survey of radiographers' confidence and self-perceived accuracy in frontline image interpretation and their continuing educational preferences

    Energy Technology Data Exchange (ETDEWEB)

    Neep, Michael J [Department of Medical Imaging, Princess Alexandra Hospital, Brisbane, Queensland (Australia); Centre for Functioning and Health Research, Metro South Health, Brisbane, Queensland (Australia); School of Public Health and Social Work and Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Queensland (Australia); Steffens, Tom [Department of Medical Imaging, Princess Alexandra Hospital, Brisbane, Queensland (Australia); Owen, Rebecca [Radiation Oncology Mater Centre, Princess Alexandra Hospital, Brisbane, Queensland (Australia); Faculty of Health, Queensland University of Technology, Brisbane, Queensland (Australia); McPhail, Steven M [Centre for Functioning and Health Research, Metro South Health, Brisbane, Queensland (Australia); School of Public Health and Social Work and Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Queensland (Australia); Department of Medical Imaging, Princess Alexandra Hospital, Brisbane, Queensland (Australia)

    2014-06-15

    The provision of a written comment on traumatic abnormalities of the musculoskeletal system detected by radiographers can assist referrers and may improve patient management, but the practice has not been widely adopted outside the United Kingdom. The purpose of this study was to investigate Australian radiographers' perceptions of their readiness for practice in a radiographer commenting system and their educational preferences in relation to two different delivery formats of image interpretation education, intensive and non-intensive. A cross-sectional web-based questionnaire was implemented between August and September 2012. Participants included radiographers with experience working in emergency settings at four Australian metropolitan hospitals. Conventional descriptive statistics, frequency histograms, and thematic analysis were undertaken. A Wilcoxon signed-rank test examined whether a difference in preference ratings between intensive and non-intensive education delivery was evident. The questionnaire was completed by 73 radiographers (68% response rate). Radiographers reported higher confidence and self-perceived accuracy to detect traumatic abnormalities than to describe traumatic abnormalities of the musculoskeletal system. Radiographers frequently reported high desirability ratings for both the intensive and the non-intensive education delivery, no difference in desirability ratings for these two formats was evident (z = 1.66, P = 0.11). Some Australian radiographers perceive they are not ready to practise in a frontline radiographer commenting system. Overall, radiographers indicated mixed preferences for image interpretation education delivered via intensive and non-intensive formats. Further research, preferably randomised trials, investigating the effectiveness of intensive and non-intensive education formats of image interpretation education for radiographers is warranted.

  6. A survey of radiographers' confidence and self-perceived accuracy in frontline image interpretation and their continuing educational preferences

    International Nuclear Information System (INIS)

    Neep, Michael J; Steffens, Tom; Owen, Rebecca; McPhail, Steven M

    2014-01-01

    The provision of a written comment on traumatic abnormalities of the musculoskeletal system detected by radiographers can assist referrers and may improve patient management, but the practice has not been widely adopted outside the United Kingdom. The purpose of this study was to investigate Australian radiographers' perceptions of their readiness for practice in a radiographer commenting system and their educational preferences in relation to two different delivery formats of image interpretation education, intensive and non-intensive. A cross-sectional web-based questionnaire was implemented between August and September 2012. Participants included radiographers with experience working in emergency settings at four Australian metropolitan hospitals. Conventional descriptive statistics, frequency histograms, and thematic analysis were undertaken. A Wilcoxon signed-rank test examined whether a difference in preference ratings between intensive and non-intensive education delivery was evident. The questionnaire was completed by 73 radiographers (68% response rate). Radiographers reported higher confidence and self-perceived accuracy to detect traumatic abnormalities than to describe traumatic abnormalities of the musculoskeletal system. Radiographers frequently reported high desirability ratings for both the intensive and the non-intensive education delivery, no difference in desirability ratings for these two formats was evident (z = 1.66, P = 0.11). Some Australian radiographers perceive they are not ready to practise in a frontline radiographer commenting system. Overall, radiographers indicated mixed preferences for image interpretation education delivered via intensive and non-intensive formats. Further research, preferably randomised trials, investigating the effectiveness of intensive and non-intensive education formats of image interpretation education for radiographers is warranted

  7. Chest radiographic findings of tsutsugamushi disease and murine typhus in Chunchon

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Heung Chul; Han, Tae Giun; Jang, Won Ho; Hwang, Woo Chul; Park, Man Soo; Lee, Myoung Gu; Kim, Yoon Won [School of Medicine, Hallym University, Chuncheon (Korea, Republic of); Park, Choong Ki [College of Medicine, Hanyang University, Guri (Korea, Republic of)

    1995-06-15

    To evaluate the chest radiographic findings of rickettsial disease including murine typhus and tsutsugamushi disease in Chunchon. Chest radiographic films of 81 cases diagnosed as rickettsial disease(55 cases of tsutsugamushi disease, 26 cases of murine typhus) by immunofluorescence test were retrospectively analyzed. Main serotypes of Rickettsia tsutsugamushi were Gilliam and Karp. Incidence rate of tsutsugamushi disease was 2.1 times greater than that of murine typhus. Chest radiographs were abnormal in 63.6% of tsutsugamushi disease, and in 30.8% of murine typhus. Radiographic findings were Kerly's B line, reticulonodular densities, hilar enlargement, pleural effusion, and splenomegaly in both entities, but pulmonary consolidation was only found in tsutsugamushi disease. The patients with the abnormal radiographic findings were statistically well correlated with cardiomegaly ({rho} < 0.01) and azygos engorgement ({rho} < 0.05), as compared to the patients with normal radiographic findings. Radiographic findings of both murine typhus and tsutsugamushi disease were interstitial pattern. But the chest radiographs in patients with tsutsugamushi disease showed more severe pattern with higher rate of abnormality.

  8. Chest radiographic findings of tsutsugamushi disease and murine typhus in Chunchon

    International Nuclear Information System (INIS)

    Kim, Heung Chul; Han, Tae Giun; Jang, Won Ho; Hwang, Woo Chul; Park, Man Soo; Lee, Myoung Gu; Kim, Yoon Won; Park, Choong Ki

    1995-01-01

    To evaluate the chest radiographic findings of rickettsial disease including murine typhus and tsutsugamushi disease in Chunchon. Chest radiographic films of 81 cases diagnosed as rickettsial disease(55 cases of tsutsugamushi disease, 26 cases of murine typhus) by immunofluorescence test were retrospectively analyzed. Main serotypes of Rickettsia tsutsugamushi were Gilliam and Karp. Incidence rate of tsutsugamushi disease was 2.1 times greater than that of murine typhus. Chest radiographs were abnormal in 63.6% of tsutsugamushi disease, and in 30.8% of murine typhus. Radiographic findings were Kerly's B line, reticulonodular densities, hilar enlargement, pleural effusion, and splenomegaly in both entities, but pulmonary consolidation was only found in tsutsugamushi disease. The patients with the abnormal radiographic findings were statistically well correlated with cardiomegaly (ρ < 0.01) and azygos engorgement (ρ < 0.05), as compared to the patients with normal radiographic findings. Radiographic findings of both murine typhus and tsutsugamushi disease were interstitial pattern. But the chest radiographs in patients with tsutsugamushi disease showed more severe pattern with higher rate of abnormality

  9. Chest radiographic findings of tsutsugamushi disease and murine typhus in Chunchon

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Heung Chul; Han, Tae Giun; Jang, Won Ho; Hwang, Woo Chul; Park, Man Soo; Lee, Myoung Gu; Kim, Yoon Won [School of Medicine, Hallym University, Chuncheon (Korea, Republic of); Park, Choong Ki [College of Medicine, Hanyang University, Guri (Korea, Republic of)

    1995-06-15

    To evaluate the chest radiographic findings of rickettsial disease including murine typhus and tsutsugamushi disease in Chunchon. Chest radiographic films of 81 cases diagnosed as rickettsial disease(55 cases of tsutsugamushi disease, 26 cases of murine typhus) by immunofluorescence test were retrospectively analyzed. Main serotypes of Rickettsia tsutsugamushi were Gilliam and Karp. Incidence rate of tsutsugamushi disease was 2.1 times greater than that of murine typhus. Chest radiographs were abnormal in 63.6% of tsutsugamushi disease, and in 30.8% of murine typhus. Radiographic findings were Kerly's B line, reticulonodular densities, hilar enlargement, pleural effusion, and splenomegaly in both entities, but pulmonary consolidation was only found in tsutsugamushi disease. The patients with the abnormal radiographic findings were statistically well correlated with cardiomegaly ({rho} < 0.01) and azygos engorgement ({rho} < 0.05), as compared to the patients with normal radiographic findings. Radiographic findings of both murine typhus and tsutsugamushi disease were interstitial pattern. But the chest radiographs in patients with tsutsugamushi disease showed more severe pattern with higher rate of abnormality.

  10. When disaster strikes; the role of the forensic radiographer

    International Nuclear Information System (INIS)

    Walsh, Mary; Reeves, Pauline; Scott, Susan

    2004-01-01

    Forensic radiography is a vital tool utilised in the many facets of Forensic Medicine. This paper investigates the role of the forensic radiographer in a mass disaster situation; it also explores the psychological impact of this type of work on radiographers. A literature review indicated that limited work had been documented on the role of the radiographer in mass disasters. This ultimately creates doubt about whether or not the radiographer is acknowledged for the vital role he/she plays and if proper provisions were in place to assess any emotional damage in the aftermath of an emotionally and physically straining situation. A qualitative method of research was used (semi-structured interviews) in order to elicit radiographers' feelings and perceptions. This method is best suited to this research topic because it is a delicate subject. Four interviews were carried out and the responses are presented in themes including emergency versus mass grave experiences (including issues of time and preparation). Other themes include the role of the radiographer and interaction with other members of the team, as well as a discussion of the aftermath of their experiences, including the feelings of pride experienced

  11. Methodology to evaluation of the density in radiographic image

    International Nuclear Information System (INIS)

    Louzada, M.J.Q.; Pela, C.A.; Belangero, W.D.; Santos-Pinto, R.

    1998-01-01

    This study was designed in order to optimize the optical densitometry technique in radiographic images by the setorization of the characteristic curves of the radiographic films. We used 24 radiographs of a stepped aluminium wedge that were taken without rigorous control development and manually revealed. The densitometric values of the steps images and its thickness, for each radiographic, was utilized to generate its particular mathematics expressions that represent its characteristic densitometric curves and then it were used for setorization. The densitometric values were obtained by a Macbeth TD528 densitometer. The study showed an optimization in the representation of the relationship between the optical density of the steps images of the wedge and its correspondent thickness, provided by the setorization, with mean square error around 10 -5 . This optimization will allow the use of this methodology in quantitative evaluations of bone mass, by radiographic images. (author)

  12. Radiographic anatomy of the medial coronoid process of dogs

    International Nuclear Information System (INIS)

    Miyabayashi, T.; Takiguchi, M.; Schrader, S.C.; Biller, D.S.

    1995-01-01

    Mediolateral, flexed mediolateral, mediocaudal-laterocranial 15 degrees oblique (extended and supinated mediolateral), and craniolateral-caudomedial 20 degrees to 30 degrees oblique radiographs of 16 elbow-joint specimens were produced to study the radiographic anatomy of the medial coronoid process. On the mediolateral view, the cranial point of the coronoid process was at the level of the distal one-third of the radial epiphysis. Degree of superimposition of the proximal radius and ulna determined how the medial coronoid process was projected on the radiographs. Mediocaudal-laterocranial oblique radiographs best showed the cranial outline of the medial coronoid process with moderate superimposition of the proximal radius and ulna

  13. Negative magnetic resonance imaging in three cases of anterior tibial cortex stress fractures

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Ralph; Moghal, M.; Newton, J.L.; Jones, N. [Oxford University Hospitals NHS Foundation Trust, Department of Sport and Exercise Medicine, Nuffield Orthopaedic Centre, Oxford (United Kingdom); Teh, J. [Oxford University Hospitals NHS Foundation Trust, Department of Radiology, Nuffield Orthopaedic Centre Oxford, Oxford (United Kingdom)

    2017-12-15

    Anterior mid-tibial cortex stress fractures (ATCSF) are uncommon and notoriously challenging to treat. They are termed high risk due to their predilection to prolonged recovery, nonunion and complete fracture. Early diagnosis is essential to avoid progression and reduce fracture complications. Imaging plays a key role in confirming the diagnosis. Magnetic resonance imaging (MRI) is accepted as the gold standard modality due to its high accuracy and nonionizing properties. This report describes three cases of ATCSFs in recreational athletes who had positive radiographic findings with no significant MRI changes. Two athletes had multiple striations within their tibias. Despite the radiographic findings, their severity of symptoms were low with mild or no tenderness on examination. Clinicians should be mindful that the ATCSFs may not present with typical acute stress fracture symptoms. We recommend that plain radiographs should be used as the first line investigation when suspecting ATCSFs. Clinicians should be aware that despite MRI being considered the gold standard imaging modality, we report three cases where the MRI was unremarkable, whilst radiographs and computed tomography confirmed the diagnosis. We urge clinicians to continue to use radiographs as the first line imaging modality for ATCSFs and not to directly rely on MRI. Those who opt directly for MRI may be falsely reassured causing a delay in diagnosis. (orig.)

  14. Negative magnetic resonance imaging in three cases of anterior tibial cortex stress fractures

    International Nuclear Information System (INIS)

    Smith, Ralph; Moghal, M.; Newton, J.L.; Jones, N.; Teh, J.

    2017-01-01

    Anterior mid-tibial cortex stress fractures (ATCSF) are uncommon and notoriously challenging to treat. They are termed high risk due to their predilection to prolonged recovery, nonunion and complete fracture. Early diagnosis is essential to avoid progression and reduce fracture complications. Imaging plays a key role in confirming the diagnosis. Magnetic resonance imaging (MRI) is accepted as the gold standard modality due to its high accuracy and nonionizing properties. This report describes three cases of ATCSFs in recreational athletes who had positive radiographic findings with no significant MRI changes. Two athletes had multiple striations within their tibias. Despite the radiographic findings, their severity of symptoms were low with mild or no tenderness on examination. Clinicians should be mindful that the ATCSFs may not present with typical acute stress fracture symptoms. We recommend that plain radiographs should be used as the first line investigation when suspecting ATCSFs. Clinicians should be aware that despite MRI being considered the gold standard imaging modality, we report three cases where the MRI was unremarkable, whilst radiographs and computed tomography confirmed the diagnosis. We urge clinicians to continue to use radiographs as the first line imaging modality for ATCSFs and not to directly rely on MRI. Those who opt directly for MRI may be falsely reassured causing a delay in diagnosis. (orig.)

  15. Optimizing radiation exposure for CT localizer radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Bohrer, Evelyn; Maeder, Ulf; Fiebich, Martin [Univ. of Applied Sciences, Giessen (Germany). Inst. of Medical Physics and Radiation Protection-IMPS; Schaefer, Stefan; Krombach, Gabriele A. [Univ. Hospital Giessen (Germany). Dept. of Radiology; Noel, Peter B. [Technische Univ. Muenchen (Germany). Dept. of Diagnostic and Interventional Radiology

    2017-08-01

    The trend towards submillisievert CT scans leads to a higher dose fraction of localizer radiographs in CT examinations. The already existing technical capabilities make dose optimization of localizer radiographs worthwhile. Modern CT scanners apply automatic exposure control (AEC) based on attenuation data in such a localizer. Therefore not only this aspect but also the detectability of anatomical landmarks in the localizer for the desired CT scan range adjustment needs to be considered. The effective dose of a head, chest, and abdomen-pelvis localizer radiograph with standard factory settings and user-optimized settings was determined using Monte Carlo simulations. CT examinations of an anthropomorphic phantom were performed using multiple sets of acquisition parameters for the localizer radiograph and the AEC for the subsequent helical CT scan. Anatomical landmarks were defined to assess the image quality of the localizer. CTDI{sub vol} and effective mAs per slice of the helical CT scan were recorded to examine the impact of localizer settings on a helical CT scan. The dose of the localizer radiograph could be decreased by more than 90% while the image quality remained sufficient when selecting the lowest available settings (80 kVp, 20 mA, pa tube position). The tube position during localizer acquisition had a greater impact on the AEC than the reduction of tube voltage and tube current. Except for the use of a pa tube position, all changes of acquisition parameters for the localizer resulted in a decreased total radiation exposure. A dose reduction of CT localizer radiograph is necessary and possible. In the examined CT system there was no negative impact on the modulated helical CT scan when the lowest tube voltage and tube current were used for the localizer.

  16. Radiographic assessment of venous catheter position in children: Value of the lateral view

    International Nuclear Information System (INIS)

    Stark, D.D.; Brasch, R.C.; Gooding, C.A.

    1984-01-01

    Frontal chest radiographs can be misleading in the evaluation of central venous catheter placement. Lateral chest radiographs were obtained, in addition to the standard frontal radiographs, in 25 young children. In five (20%) of the children, the catheters were found to be malpositioned, and the frontal radiograph showed evidence of the abnormality in all five. The lateral radiographs also showed evidence of the abnormality in all five children; however, in three of the five, the lateral radiographs provided additional, more specific, diagnostic information. The lateral chest radiographs also demonstrated satisfactory catheter positioning in three other children in whom the frontal radiographs suggested abnormal positioning. Accurate assessment of catheter position was possible in all patients using both frontal and lateral chest radiographs. Injection of contrast material was not necessary to locate malpositioned catheters. Lateral radiographs are recommended whenever an abnormal catheter position is suspected clinically or from findings on the routine frontal radiograph. (orig.)

  17. Factors for lifelong job retention among Swiss radiographers

    International Nuclear Information System (INIS)

    Lehmann, P.; Meystre, N. Richli; Mamboury, N.

    2015-01-01

    In Switzerland, a shortage of radiographers in the three radiology domains, radio-diagnostic, radiotherapy and nuclear medicine, is supposed to increase in the upcoming years. As job satisfaction has been shown to contribute to workplace retention, one purpose of the study was to explore the relationship between workplace retention and duration in the profession with job satisfaction. The study was based on two surveys. The institutional survey was addressed to all chiefs of radiology units in hospitals and ambulatory institutes (340, response rate 48%). All radiographers were asked to complete the individual survey (3000, response rate 25%). Two thirds of radiographers had been employed for five or more years in the same workplace, and nearly half intended to stay for 10 more years. The professional lifespan of radiographers is estimated to be approximately 27 years. 75% expressed their satisfaction with key aspects of professional activity, including the content of the work, autonomy, technology and their relationships with professionals and patients. These factors were not linked to a particular workplace, but to the profession itself. The radiographers build their own propitious work environment, even if salary and recognition by physicians are contributing to their dissatisfaction. The retention in the profession, consolidated by a high level of satisfaction, is an essential feature for a workforce policy. However, active measures for reinforcing retention are still necessary when considering that a lifelong career needs challenges and rewards. Additionally, the retention rate does not provide a guarantee adequacy for the future projected needs in the profession. - Highlights: • Retention in the profession, with a high level of satisfaction, is a major point for a workforce policy. • Job satisfaction of radiographers is not linked to a particular workplace, but to the profession itself. • The professional lifespan of radiographers in Switzerland is

  18. Occupational kneeling and radiographic tibiofemoral and patellofemoral osteoarthritis

    DEFF Research Database (Denmark)

    Rytter, Søren; Egund, Niels; Jensen, Lilli Kirkeskov

    2009-01-01

    ABSTRACT: BACKGROUND: The objective of our study was to evaluate the association between occupational kneeling and compartment specific radiographic tibiofemoral (TF) and patellofemoral (PF) osteoarthritis (OA). METHODS: Questionnaire data and bilateral knee radiographs were obtained in 134 male...

  19. Stress analysis program system for nuclear vessel: STANSAS

    International Nuclear Information System (INIS)

    Okamoto, Asao; Michikami, Shinsuke

    1979-01-01

    IHI has developed a computer system of stress analysis and evaluation for nuclear vessels: STANSAS (STress ANalysis System for Axi-symmetric Structure). The system consists of more than twenty independent programs divided into the following six parts. 1. Programs for opening design by code rule. 2. Calculation model generating programs. 3. Load defining programs. 4. Structural analysis programs. 5. Load data/calculation results plotting programs. 6. Stress evaluation programs. Each program is connected with its pre- or post-processor through three data-bases which enable automatic data transfer. The user can make his choice of structural analysis programs in accordance with the problem to be solved. The interface to STANSAS can be easily installed in generalized structural analysis programs such as NASTRAN and MARC. For almost all tables and figures in the stress report, STANSAS has the function to print or plot out. The complicated procedures of ''Design by Analysis'' for pressure vessels have been well standardized by STANSAS. The system will give a high degree of efficiency and confidence to the design work. (author)

  20. Understanding chest radiographic anatomy with MDCT reformations

    Energy Technology Data Exchange (ETDEWEB)

    Sussmann, A.R. [Department of Radiology, Thoracic Imaging, NYU Langone Medical Center, New York, NY (United States); Ko, J.P., E-mail: jane.ko@nyumc.or [Department of Radiology, Thoracic Imaging, NYU Langone Medical Center, New York, NY (United States)

    2010-02-15

    Chest radiograph interpretation requires an understanding of the mediastinal reflections and anatomical structures. Computed tomography (CT) improves the learning of three-dimensional (3D) anatomy, and more recently multidetector CT (MDCT) technology has enabled the creation of high-quality reformations in varying projections. Multiplanar reformations (MPRs) of varying thickness in the coronal and sagittal projections can be created for direct correlation with findings on frontal and lateral chest radiographs, respectively. MPRs enable simultaneous visualization of the craniocaudal extent of thoracic structures while providing the anatomic detail that has been previously illustrated using cadaveric specimens. Emphasis will be placed on improving knowledge of mediastinal anatomy and reflections including edges, lines, and stripes that are visible on chest radiographs.

  1. Radiographic anatomy of the proximal femur: femoral neck fracture vs. transtrochanteric fracture

    Directory of Open Access Journals (Sweden)

    Ana Lecia Carneiro Leão de Araújo Lima

    Full Text Available ABSTRACT OBJECTIVE: To evaluate the correlation between radiographic parameters of the proximal femur with femoral neck fractures or transtrochanteric fractures. METHODS: Cervicodiaphyseal angle (CDA, femoral neck width (FNW, hip axis length (HAL, and acetabular tear drop distance (ATD were analyzed in 30 pelvis anteroposterior view X-rays of patients with femoral neck fractures (n = 15 and transtrochanteric fractures (n = 15. The analysis was performed by comparing the results of the X-rays with femoral neck fractures and with transtrochanteric fractures. RESULTS: No statistically significant differences between samples were observed. CONCLUSION: There was no correlation between radiographic parameters evaluated and specific occurrence of femoral neck fractures or transtrochanteric fractures.

  2. Comparison of three contrast radiographic techniques in the dog large intestine

    International Nuclear Information System (INIS)

    Vargas, L.; Thibaut, J.; Olhaberry, E.; Born, R.; Deppe, R.

    1994-01-01

    In order to compare three radiographic techniques -pneumocolon, barium enema and double contrast- in the large intestine of the dog, three radiographic series in ventrodorsal and right lateral projections were taken. Six healthy adult dogs of both sexes with an approximate weight between 5 to 10 kg were used. Three enemas were administered 24, 12 and 2 hrs. before the series of radiographs were taken. Then dogs were anaesthetized with sodium tiopental (20 mg/kg iv) and the contrast media were introduced. Pneumocolon was carried out in the first series introducing air (20 cc/kg) in the large intestine through a Foley rectal catheter. Radiographs were taken in both projections, after 5 and 15min. respectively. Barium enema was performed in the second series introducing barium sulfate (18%) in the large intestine through a Foley rectal catheter (25 cc/kg); 5 and 15 min. later, the radiographs were taken. In the third series -double contrast- the barium sulfate, which was obtained from each dog using a catheter, was substituted by a volume of air equal to that obtained from the contrast medium. Later the radiographs were taken in both projections. The radiographic plates of each series were analized comparing the characteristics of: radiographic density, outline and volume. With the pneumocolon barium enema and double contrast, the radiographic density was, in most cases, low, high and inter-mediate respectively. The radiographic outline was, in most cases, regular for the three techniques. Thee radiographic volume was similar in all of the series. From the results obtained, it is concluded that double contrast best outlines the intestinal mucosa and more information can be obtained from it [es

  3. Chest radiographic abnormalities in HIV-infected African children: a longitudinal study.

    Science.gov (United States)

    Pitcher, Richard D; Lombard, Carl J; Cotton, Mark F; Beningfield, Stephen J; Workman, Lesley; Zar, Heather J

    2015-09-01

    There is limited knowledge of chest radiographic abnormalities over time in HIV-infected children in resource-limited settings. To investigate the natural history of chest radiographic abnormalities in HIV-infected African children, and the impact of antiretroviral therapy (ART). Prospective longitudinal study of the association of chest radiographic findings with clinical and immunological parameters. Chest radiographs were performed at enrolment, 6-monthly, when initiating ART and if indicated clinically. Radiographic abnormalities were classified as normal, mild or moderate severity and considered persistent if present for 6 consecutive months or longer. An ordinal multiple logistic regression model assessed the association of enrolment and time-dependent variables with temporal radiographic findings. 258 children (median (IQR) age: 28 (13-51) months; median CD4+%: 21 (15-24)) were followed for a median of 24 (18-42) months. 70 (27%) were on ART at enrolment; 130 (50%) (median age: 33 (18-56) months) commenced ART during the study. 154 (60%) had persistent severe radiographic abnormalities, with median duration 18 (6-24) months. Among children on ART, 69% of radiographic changes across all 6-month transition periods were improvements, compared with 45% in those not on ART. Radiographic severity was associated with previous radiographic severity (OR=120.80; 95% CI 68.71 to 212.38), lack of ART (OR=1.72; 95% CI 1.29 to 2.27), enrolment age ART was beneficial, reducing the risk of radiographic deterioration or increasing the likelihood of radiological improvement. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  4. PDX vacuum vessel stress analysis

    International Nuclear Information System (INIS)

    Nikodem, Z.D.

    1975-01-01

    A stress analysis of PDX vacuum vessel is described and the summary of results is presented. The vacuum vessel is treated as a toroidal shell of revolution subjected to an internal vacuum. The critical buckling pressure is calculated. The effects of the geometrical discontinuity at the juncture of toroidal shell head and cylindrical outside wall, and the concavity of the cylindrical wall are examined. An effect of the poloidal field coil supports and the vessel outside supports on the stress distribution in the vacuum vessel is determined. A method evaluating the influence of circular ports in the vessel wall on the stress level in the vessel is outlined

  5. Meaning contents of radiographers' professional identity as illustrated in a professional journal - A discourse analytical approach

    Energy Technology Data Exchange (ETDEWEB)

    Niemi, Antti [University of Oulu, Department of Nursing Science and Health Administration, P.O. Box 5000, 90014 Oulu (Finland)], E-mail: antti.niemi@oulu.fi; Paasivaara, Leena [University of Oulu, Department of Nursing Science and Health Administration, P.O. Box 5000, 90014 Oulu (Finland)], E-mail: leena.paasivaara@oulu.fi

    2007-11-15

    Aim: The purpose of the present study is to describe and understand the meaning contents of radiographers' professional identity. Background: The conceptualisation of professional identity in terms of radiographers' perceptions of their role focuses on their preferred role-content and perception of the professional self. Professional identity defines values and beliefs that guide the radiographer's thinking, actions and interaction. Method: The present study employs the method of discourse analysis to gain a profound understanding of the cultural meaning contents related to the formation of the professional identity of radiographers. Material for the study was gathered from articles published in the professional journal of the Society of Radiographers in Finland between the years 1987 and 2003. Findings: Technical discourse emphasised the importance of responding to the changes in radiology in the 1990s. Safety discourse emerged as the second content of meaning describing the formation of professional identity. The third content of meaning in professional identity was professional discourse, a central aspect being to promote the esteem of one's profession and emphasise professional identity. Conclusions: The results suggest that the professional identity of a radiographer is dual in nature. On one hand, the professional identity of a radiographer is based on solid command of scientific-mechanic technology in a technical working environment; while on the other hand, it consists of mastering the humane, humanistic nursing work.

  6. Retention of anatomy knowledge by student radiographers

    International Nuclear Information System (INIS)

    Hall, A. Susanne; Durward, Brian R.

    2009-01-01

    Introduction: Anatomy has long been regarded as an integral part of the core curriculum. However, anecdotal evidence suggests that long-term retention of anatomy knowledge may be deficient. This study aims to evidence whether student radiographers demonstrate the same level of knowledge of anatomy after a period of time has elapsed and to correlate to approaches to learning and studying. Methodology: A repeated measures design was utilised to measure retention of anatomy knowledge for both MCQs and short-response answers to a Practical Radiographic Anatomy Examination; alpha value p < 0.05. Fifty-one students from levels 2 and 3 were retested after a time lapse of 10 and 22 months respectively. The students were not aware that their knowledge was being retested. Approaches to learning and studying were measured using the ASSIST inventory. Results: Statistical analysis found no difference in performance on MCQ assessment, in either the combined sample or levels 2 and 3 separately, from baseline to retention occasions; average retention rate being 99%. However, a statistical difference in performance on PRAE assessment was found, with level 2 experiencing a larger reduction in scores; retention rate of 67% compared to level 3 at 77%. The students perceived themselves to be principally strategic in their approach to learning and studying but no strong relationships were found when correlated to test scores. Conclusion: The student radiographers in this study demonstrated varied anatomy retention rates dependent on assessment method employed and time interval that had elapsed. It is recommended that diverse teaching and assessment strategies are adopted to encourage a deeper approach to learning and studying.

  7. Dental radiographic units - radiation safety and patient doses

    International Nuclear Information System (INIS)

    Nagpal, J.S.; Varadharajan, Geetha

    2001-01-01

    Three models of dental radiographic machines have been examined for radiation safety. Using TL dosemeters, doses received by the patients at chest level and the gonads have been estimated. Care should be taken to shield gonads during dental radiographic examinations. (author)

  8. A survey of the radiographic cassettes disinfection of university hospitals in seoul

    International Nuclear Information System (INIS)

    Kweon, Dae Cheol; Park, Peom; Kim, Moon Sun; Kim, Dong Sung

    2001-01-01

    The purpose of this study is to prevent nosocomial infection in patients through contact of radiographic cassettes. Data were collected from radiographers working in 29 university hospitals in Seoul in February and March 2001. Radiographic cassettes were disinfected daily in 5 hospitals, weekly in 4 hospitals, monthly in 5 hospitals, bimonthly in 1 hospital and once every three months in another hospital. 12 other hospitals do not practice regular disinfections of radiographic cassettes. Gauze soaked in disinfectant solution is used in 7 hospitals while 11 hospitals used cotton and cloth soaked in disinfectant solution to clean the radiographic cassettes. 26 hospitals used 99% alcohol based disinfectant solutions while 3 hospitals used 75% alcohol based disinfectant, 26 hospitals use of intercourse cassettes outpatients and in patients. In 26 hospitals, all patients shared the same set of radiographic cassettes used in the hospitals, or in 26 hospitals, separate sets of radiographic cassettes are used for outpatients and inpatients. Separate sets of cassettes are used for ICU and inpatients in 6 others hospitals. 23 hospitals used the same sets of radiographic cassettes for all their patients. radiographic cassettes are cleaned in wash area in the study room of the radiographic department in 17 hospitals. 12 other hospitals do not have designated cleaning areas for the cassettes. All radiographers practiced hands washing with soap. All 29 hospitals surveyed have infection control committee. However, only 9 out of the 29 hospitals surveyed provided Infection · disinfections control education to radiographers. Only 3 hospitals have radiographers sitting in the infection control committee. Infection management education is conducted in 63 hospitals annually, twice a year in 1 hospital and once every 3 months in 2 hospitals

  9. Influence of Radiographic Positioning on Canine Sacroiliac and Lumbosacral Angle Measurements.

    Science.gov (United States)

    Jones, Susan; Savage, Mason; Naughton, Brian; Singh, Susheela; Robertson, Ian; Roe, Simon C; Marcellin-Little, Denis J; Mathews, Kyle G

    2018-01-01

     To evaluate the influence of radiographic malpositioning on canine sacroiliac and lumbosacral inclination angles.  Using canine cadavers, lateral pelvic radiographs were acquired with the radiographic beam in a neutral position and then rotated 5, 10 and 15° to mimic rotational malpositioning. The focal point of the beam was then focused over the abdomen and again over mid-diaphysis of the femur to mimic an abdominal or femoral radiographic study.  Five degrees of rotational malpositioning did not influence measurements of sacroiliac or lumbosacral inclination, but malpositioning by more than 5° led to a significant decrease in both sacroiliac and lumbosacral angles. Moving the focal point to the femur significantly decreased the measured lumbosacral angle. Abdominally centred radiographs had no effect on lumbosacral and sacroiliac angle measurements.  When evaluating canine lumbosacral and sacroiliac angles radiographically, pelvic rotation of more than 5° should be avoided as should the use of lateral radiographs centred over the femur. Schattauer GmbH Stuttgart.

  10. Comparison of ultrasonographic and radiographic findings in cows with traumatic reticuloperitonitis

    International Nuclear Information System (INIS)

    Braun, U.; Fluckiger, M.; Gotz, M.

    1994-01-01

    The radiographic and ultrasonographic findings in 26 cows with traumatic reticuloperitonitis were compared. The cows were divided into three groups based on the radiographic findings; the first group consisted of 12 cows in which the principal radiographic finding was a foreign body penetrating the reticulum; the second group contained four cows in which the principal radiographic finding was gas shadows or a gas-fluid interface, the third group consisted of 10 cows that had no reliable radiographic evidence of traumatic reticuloperitonitis, such as an abnormal contour, position or shape of the reticulum. In no case could the foreign bodies be visualised by ultrasonography. In all the cows except one with radiographic evidence of abnormal gas inclusions and gas-fluid interfaces, ultrasonography revealed echogenic, partitioned and capsulated structures with central hypoechogenic cavities. In addition, in some of the cows with no radiographic evidence of the condition, severe changes indicative of inflammatory processes were visible by ultrasonography

  11. Is the frontal radiograph alone sufficient to evaluate for pneumonia in children?

    International Nuclear Information System (INIS)

    Rigsby, Cynthia K.; Strife, Janet L.; Johnson, Neil D.; Atherton, Harry D.; Kotagal, Uma R.; Pommersheim, William

    2004-01-01

    In our cost- and radiation-conscious environment, the feasibility of performing only a frontal radiograph for the diagnosis of pneumonia in children needs to be reassessed. To determine the diagnostic efficacy of the frontal radiograph alone in comparison to the frontal and lateral combined radiographs for the radiographic diagnosis of pneumonia in children. Three radiologists retrospectively and independently reviewed the frontal radiographs alone and separately reviewed the frontal and lateral radiographs of 1,268 children referred from the emergency room for chest radiographs. A majority interpretation of at least two radiologists for the frontal views alone was compared with majority interpretation of the frontal and lateral combined views for the radiographic diagnosis of pneumonia. ''Pneumonia'' was defined as a focus of streaky or confluent lung opacity. For the radiographic diagnosis of pneumonia, the sensitivity and specificity of the frontal view alone were 85% and 98%, respectively. For the confluent lobar type of pneumonia, the sensitivity and specificity increased to 100%. When the frontal view alone yields a diagnosis of confluent lobar pneumonia, this is highly reliable. However, nonlobar types of infiltrates will be underdiagnosed in 15% of patients using the frontal view alone. The clinical impact of these radiographically underdiagnosed pneumonias needs to be assessed prior to implementing the practice of using only frontal radiographs for diagnosing pneumonia. (orig.)

  12. Is the frontal radiograph alone sufficient to evaluate for pneumonia in children?

    Energy Technology Data Exchange (ETDEWEB)

    Rigsby, Cynthia K. [Department of Radiology, Children' s Hospital Medical Center, 3333 Burnet Avenue, OH 45229, Cincinnati (United States); Department of Medical Imaging No. 9, Children' s Memorial Hospital, 2300 Children' s Plaza, IL 60614, Chicago (United States); Strife, Janet L.; Johnson, Neil D. [Department of Radiology, Children' s Hospital Medical Center, 3333 Burnet Avenue, OH 45229, Cincinnati (United States); Atherton, Harry D.; Kotagal, Uma R. [Department of Health Policy and Clinical Effectiveness, Children' s Hospital Medical Center, 3333 Burnet Avenue, OH 45229, Cincinnati (United States); Pommersheim, William [Department of Radiology, Children' s Hospital Medical Center, 3333 Burnet Avenue, OH 45229, Cincinnati (United States); Wake Forest University Baptist Medical Center, Department of Radiology, Meads Hall, 2nd Floor, NC 27157, Winston-Salem (United States)

    2004-05-01

    In our cost- and radiation-conscious environment, the feasibility of performing only a frontal radiograph for the diagnosis of pneumonia in children needs to be reassessed. To determine the diagnostic efficacy of the frontal radiograph alone in comparison to the frontal and lateral combined radiographs for the radiographic diagnosis of pneumonia in children. Three radiologists retrospectively and independently reviewed the frontal radiographs alone and separately reviewed the frontal and lateral radiographs of 1,268 children referred from the emergency room for chest radiographs. A majority interpretation of at least two radiologists for the frontal views alone was compared with majority interpretation of the frontal and lateral combined views for the radiographic diagnosis of pneumonia. ''Pneumonia'' was defined as a focus of streaky or confluent lung opacity. For the radiographic diagnosis of pneumonia, the sensitivity and specificity of the frontal view alone were 85% and 98%, respectively. For the confluent lobar type of pneumonia, the sensitivity and specificity increased to 100%. When the frontal view alone yields a diagnosis of confluent lobar pneumonia, this is highly reliable. However, nonlobar types of infiltrates will be underdiagnosed in 15% of patients using the frontal view alone. The clinical impact of these radiographically underdiagnosed pneumonias needs to be assessed prior to implementing the practice of using only frontal radiographs for diagnosing pneumonia. (orig.)

  13. Bone scanning in the evaluation of exercise-related stress injuries

    International Nuclear Information System (INIS)

    Wilcox, J.R. Jr.; Moniot, A.L.; Green, J.P.

    1977-01-01

    Bone scintigraphy was used to evaluate 34 patients with the physical findings and history of stress fracture of the lower extremity. Of the 34, 21 had abnormal studies, 11 involving the femoral neck, 9 the tibia, and 1 the femur. All of these had abnormal scintiscans prior to or at the time of the appearance of radiographic changes. Of the 9 with abnormal tibial studies, radiographic changes never evolved in 3. No false negatives were found among the 13 with normal scintiscans

  14. Comparison of the critical shoulder angle in radiographs and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bouaicha, Samy [University of British Columbia, Divison of Arthroscopic, Reconstructive Surgery and Joint Preservation, Department of Orthopaedics, Vancouver (Canada); Zurich University Hospital, Division of Trauma, Zurich (Switzerland); Ehrmann, Christine [University of British Columbia, Department of Radiology, Vancouver (Canada); Slankamenac, Ksenija [Zurich University Hospital, Division of Trauma, Zurich (Switzerland); Regan, William D. [University of British Columbia, Divison of Arthroscopic, Reconstructive Surgery and Joint Preservation, Department of Orthopaedics, Vancouver (Canada); Moor, Beat K. [Insel University Hospital, Department of Orthopaedics, Berne (Switzerland)

    2014-08-15

    The critical shoulder angle (CSA) is an indicator of degenerative shoulder pathologies. CSAs above 35 are associated with degenerative rotator cuff disease, whereas values below 30 are common in osteoarthritis of the glenohumeral joint. Measurements are usually performed on radiographs; however, no data have been reported regarding the reliability of CT scan measurements between different readers or the reproducibility of measurements from radiographs to CT scans. The purpose of our study was to clarify whether CSA measurements on radiographs and CT scans of the same patients show similar values. CSA measurements of 60 shoulders (59 patients) were performed on radiographs and multiplanar reconstructions of corresponding CT scans. Inter-reader reliability and inter-method correlation were calculated. The mean discrepancy between readers was only 0.2 (SD ±1.0 ) on radiographs. CT scan measurements showed a mean discrepancy of 0.3 (SD ±1.2 ). The inter-reader reliability was 0.993 for radiographs and 0.989 for CT scans. There was a very strong inter-method correlation between the CSA measured on radiographs and CT scans (Spearman's rho = 0.974). The mean differences between angles on radiographs and CT measurements were -0.05 (SD ±1.2 ) and 0.1 (SD ±1.2 ), respectively. Measurements of the CSA on anterior-posterior radiographs and CT scans are highly correlated, and inter-modality differences are negligible. (orig.)

  15. Can We Measure the Heel Bump? Radiographic Evaluation of Haglund's Deformity.

    Science.gov (United States)

    Bulstra, Gythe H; van Rheenen, Thijs A; Scholtes, Vanessa A B

    2015-01-01

    Haglund's deformity is a symptomatic posterosuperior deformity of the heel. The lateral radiograph of the ankle will show a prominent, large, posterosuperior part of the calcaneus, which can be measured using the Fowler and Philips angle (FPA, the angle between the posterior and plantar surface of the calcaneus) and the calcaneal pitch angle (CPA, the angle between the sole of the foot and the plantar part of the calcaneus). Although these angles are commonly used, these radiographic angle measurements have never shown a relationship with Haglund's deformity. In 78 patients (51% male) with symptomatic Haglund's deformity and a control group of 100 patients (41% male) with no heel complaints, we measured the FPA and CPA on weightbearing lateral radiographs of the foot. Using an unpaired t tests, no significant difference was found between the 2 groups in the FPA (p = .40). We measured a significant difference in the CPA between the Haglund group and the control group (p = .014). Subgroup analysis showed that this difference was mainly found in females (p verticalization of the calcaneus. This change in position results in extra traction on the Achilles tendon and can eventually cause tendinitis and bursitis. Radiographic measurement should be used as an auxiliary tool. If the calcaneus tends to change position, it would be interesting to understand this process, which could eventually lead to improvement in the treatment of Haglund's deformity. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  16. X-ray stress analysis of residual stress gradients in surface layers of steel

    International Nuclear Information System (INIS)

    Ganev, N.; Kraus, I.; Gosmanova, G.; Pfeiffer, L.; Tietz, H.-D.

    2001-01-01

    The aim of the contribution is to present the theoretical possibilities of X-ray non-destructive identification of stress gradients within the penetration depth of used radiation and its utilization for experimental stress analysis. Practical usefullness of outlined speculations is illustrated with results of stress measurements on cut and shot-penned steel samples. (author)

  17. Thermographic Analysis of Stress Distribution in Welded Joints

    Directory of Open Access Journals (Sweden)

    Domazet Ž.

    2010-06-01

    Full Text Available The fatigue life prediction of welded joints based on S-N curves in conjunction with nominal stresses generally is not reliable. Stress distribution in welded area affected by geometrical inhomogeneity, irregular welded surface and weld toe radius is quite complex, so the local (structural stress concept is accepted in recent papers. The aim of this paper is to determine the stress distribution in plate type aluminum welded joints, to analyze the reliability of TSA (Thermal Stress Analysis in this kind of investigations, and to obtain numerical values for stress concentration factors for practical use. Stress distribution in aluminum butt and fillet welded joints is determined by using the three different methods: strain gauges measurement, thermal stress analysis and FEM. Obtained results show good agreement - the TSA mutually confirmed the FEM model and stresses measured by strain gauges. According to obtained results, it may be stated that TSA, as a relatively new measurement technique may in the future become a standard tool for the experimental investigation of stress concentration and fatigue in welded joints that can help to develop more accurate numerical tools for fatigue life prediction.

  18. Thermographic Analysis of Stress Distribution in Welded Joints

    Science.gov (United States)

    Piršić, T.; Krstulović Opara, L.; Domazet, Ž.

    2010-06-01

    The fatigue life prediction of welded joints based on S-N curves in conjunction with nominal stresses generally is not reliable. Stress distribution in welded area affected by geometrical inhomogeneity, irregular welded surface and weld toe radius is quite complex, so the local (structural) stress concept is accepted in recent papers. The aim of this paper is to determine the stress distribution in plate type aluminum welded joints, to analyze the reliability of TSA (Thermal Stress Analysis) in this kind of investigations, and to obtain numerical values for stress concentration factors for practical use. Stress distribution in aluminum butt and fillet welded joints is determined by using the three different methods: strain gauges measurement, thermal stress analysis and FEM. Obtained results show good agreement - the TSA mutually confirmed the FEM model and stresses measured by strain gauges. According to obtained results, it may be stated that TSA, as a relatively new measurement technique may in the future become a standard tool for the experimental investigation of stress concentration and fatigue in welded joints that can help to develop more accurate numerical tools for fatigue life prediction.

  19. Conventional frontal radiographs compared with frontal radiographs obtained from cone beam computed tomography.

    Science.gov (United States)

    Nur, Metin; Kayipmaz, Saadettin; Bayram, Mehmet; Celikoglu, Mevlut; Kilkis, Dogan; Sezgin, Omer Said

    2012-07-01

    To test the hypothesis that there is no difference between measurements performed on conventional frontal radiographs (FRs) and those performed on FRs obtained from cone beam computed tomography (CBCT) scans. This study consisted of conventional FRs and CBCT-constructed FRs obtained from 30 young adult patients. Twenty-three landmarks were identified on both types of cephalometric radiographs. Twenty-one widely used cephalometric variables (14 linear distances, 4 angles, and 3 ratios) were calculated. Paired t-tests were performed to compare the means of corresponding measurements on two cephalometric radiographs of the same patient. Reproducibility of measurements ranged from 0.85 to 0.99 for CBCT-constructed FRs, and from 0.78 to 0.96 for conventional FRs. A statistically significant difference was observed between conventional FRs and CBCT-constructed FRs for all linear measurements (eurR-eurL, loR-loL, moR-moL, zygR-zygL, lapR-lapL, mxR-mxL, maR-maL, umR-umL, lmR-lmL, agR-agL, me-ans) (P .05). However, no statistically significant differences were noted between conventional FRs and CBCT-constructed FRs for ratios and angular measurements (P > .05). The hypothesis was rejected. A difference has been noted between measurements performed on conventional FRs and those performed on CBCT-constructed FRs, particularly in terms of linear measurements.

  20. Evaluating the role of the diagnostic research radiographer

    International Nuclear Information System (INIS)

    Reid, Karen; Edwards, Hazel

    2011-01-01

    The NHS has an increasingly strong focus on evidence-based medicine to underpin policy making and the development of a culture of evaluation and learning. Good quality research is the foundation for this ethos. Numbers of research projects and clinical trials involving imaging are increasing and therefore more radiographers are contributing to these studies but perhaps on some occasions they may be unaware. This paper describes the benefits of having a dedicated research radiographer within a radiology department to organise and monitor studies. We explain the procedures of the research process, the knowledge and skills that such a radiographer requires and the value of coordination and governance in developing a culture of research in a radiology department. We make suggestions to overcome perceived barriers to engaging with research and discuss the advantages and limitations of the role. Others who are considering appointing a dedicated research radiographer may find our experience helpful.

  1. Reading screening mammograms - Attitudes among radiologists and radiographers about skill mix

    DEFF Research Database (Denmark)

    Johansen, Lena Westphal; Brodersen, John

    2011-01-01

    INTRODUCTION: Because of shortage of personnel for the Danish mammography screening programme, the aim of this study was to investigate the attitudes of radiologists and radiographers towards a future implementation of radiographers reading screening mammograms. MATERIALS AND METHODS: Seven...... of managers, and improved working relations. Organization related obstacles: shortage of radiographers and negative attitudes of managers. Professional related possibilities: positive experience with skill mix. Professional related obstacles: worries about negative consequences for the training...... and financial consequences of skill mix. Despite of this all radiologists and radiographers experienced with skill mix were strong advocates for reading radiographers....

  2. Radiographer-led breast boost localisation – A service evaluation study

    International Nuclear Information System (INIS)

    Smith, S.; Comins, C.

    2015-01-01

    A radiation boost to the tumour bed as part of breast conserving therapy reduces the rate of local recurrence. Radiographer-led planning for tangential field radiotherapy has been the practice at our centre since 2007. The transition from conventional simulation to computed tomography (CT) and virtual simulation enhanced the radiographer's role in the breast planning process. Electron boost mark ups continued to be marked up freehand by doctors using available imaging to determine tumour bed. The paper reports on a service evaluation undertaken to establish a change in practice for electron breast boosts to be simulated using the virtual simulator by suitably trained radiographers. The retrospective simulation of ten patients confirmed the consistency of radiographer tumour bed localisation, followed by the prospective simulation of ten patients' boost fields. The introduction of a radiographer-led planning breast boost service has given greater autonomy and job satisfaction to individuals as well as resulting in a cost effective use of available resources. - Highlights: • A service evaluation study was undertaken to train a radiographer to perform breast boost planning. • Retrospective breast boost planning established proposed technique was workable. • Prospective planning by radiographer proved their competence. • Introduction of new technique provided job satisfaction and service improvement

  3. Pulmonary edema: radiographic differential diagnosis

    International Nuclear Information System (INIS)

    Yoo, Dong Soo; Choi, Young Hi; Kim, Seung Cheol; An, Ji Hyun; Lee, Jee Young; Park, Hee Hong

    1997-01-01

    To evaluate the feasibility of using chest radiography to differentiate between three different etiologies of pulmonary edema. Plain chest radiographs of 77 patients, who were clinically confirmed as having pulmonary edema, were retrospectively reviewed. The patients were classified into three groups : group 1 (cardiogenic edema : n = 35), group 2 (renal pulmonary edema : n = 16) and group 3 (permeability edema : n = 26). We analyzed the radiologic findings of air bronchogram, heart size, peribronchial cuffing, septal line, pleural effusion, vascular pedicle width, pulmonary blood flow distribution and distribution of pulmonary edema. In a search for radiologic findings which would help in the differentiation of these three etiologies, each finding was assessed. Cardiogenic and renal pulmonary edema showed overlapping radiologic findings, except for pulmonary blood flow distribution. In cardiogenic pulmonary edema (n=35), cardiomegaly (n=29), peribronchial cuffing (n=29), inverted pulmonary blood flow distribution (n=21) and basal distribution of edema (n=20) were common. In renal pulmonary edema (n=16), cardiomegaly (n=15), balanced blood flow distribution (n=12), and central (n=9) or basal distribution of edema (n=7) were common. Permeability edema (n=26) showed different findings. Air bronchogram (n=25), normal blood flow distribution (n=14) and peripheral distribution of edema (n=21) were frequent findings, while cardiomegaly (n=7), peribronchial cuffing (n=7) and septal line (n=5) were observed in only a few cases. On plain chest radiograph, permeability edema can be differentiated from cardiogenic or renal pulmonary edema. The radiographic findings which most reliably differentiated these two etiologies were air bronchogram, distribution of pulmonary edema, peribronchial cuffing and heart size. Only blood flow distribution was useful for radiographic differentiation of cardiogenic and renal edema

  4. Radiographic analysis of the temporomandibular joint by the standardized projection technique

    International Nuclear Information System (INIS)

    Choe, Han Up; Park, Tae Won

    1983-01-01

    The purpose of this study was to investigate the radiographic images of the condylar head in clinically normal subjects and the TMJ patients using standardized projection technique. 45 subjects who have not clinical evidence of TMJ problems and 96 patients who have the clinical evidence of TMJ problems were evaluated, but the patients who had fracture, trauma and tumor on TMJ area were discluded in this study. For the evaluation of radiographic images, the author has observed the condylar head positions in closed mouth and 2.54 cm open mouth position taken by the standardized transcranial oblique lateral projection technique. The results were as follow: 1. In closed mouth position, the crest of condylar head took relatively posterior position to the deepest point of the glenoid fossa in 8.9% of the normals and in 26.6% of TMJ patients. 2. In 2.54 cm open mouth position, condylar head took relatively posterior position to the articular eminence in 2 .2% of TMJ patients and 39.6% of the normals. 3. In open mouth position, the horizontal distance from the deepest point of the glenoid fossa to the condylar head was 13.96 mm in the normals and 10.68 mm in TMJ patients. 4. The distance of true movement of condylar head was 13.49 mm in the normals and 10.27 mm in TMJ patients. 5. The deviation of mandible in TMJ patients was slightly greater than of the normals.

  5. Limitations of radiographs in evaluating non-displaced osteochondral lesions of the talus

    International Nuclear Information System (INIS)

    Dheer, Sachin; Khan, Mustafa; Zoga, Adam C.; Morrison, William B.

    2012-01-01

    To evaluate what limitations, if any, radiographs have in detecting and characterizing the morphology of non-displaced OCLTs (size, cystic change, fragmentation, and avascular necrosis [AVN]). Thirty-three OCLTs in 32 patients were reviewed in consensus by a board-certified, fellowship-trained musculoskeletal radiologist and orthopedic surgeon, on radiographs and MRI examinations performed within 15 days of one another. Location, dimensions, and characteristics of the OCLT (fragmentation, bone marrow edema, cystic change, and necrosis) were documented on the radiographs and MRI examinations. There was an average of 7.5 days (range: 1-15 days) between the MRIs and radiographs. Eighteen (55%) medial and 15 (45%) lateral OCLTs were found; none was displaced. OCLTs were categorized into three groups: Group 1 - initially diagnosed with radiographs (4/33; 12%), Group 2 - diagnosed with radiographs only after MRI correlation (20/33; 61%), and Group 3 - not identifiable on radiographs despite MRI correlation (9/33; 27%). The dimensions of all of the lesions in Groups 1 and 2 were underestimated on radiographs. Only 1 of the 4 (25%) lesions in Group 1 and 1 of the 20 (5%) lesions in Group 2 could be measured in the anteroposterior (AP) dimension (using a lateral radiograph). The most common radiographic appearance of non-displaced OCLTs was an ''ill-defined'' lucency at the talar dome (20/33; 61%). Across all three groups, fragmentation, cystic change, and AVN were radiographically apparent in 3/10 (30%), 4/19 (21%), and 1/6 (17%) cases respectively. Compared with MRI, radiographs are limited in their evaluation of the size (particularly the AP dimension) and characteristics (fragmentation, cystic change, and AVN) of non-displaced OCLTs. The most common appearance of non-displaced OCLTs is an ''ill-defined'' lucency at the talar dome. When this appearance is also considered, the estimated retrospective sensitivity of radiographs improves considerably. (orig.)

  6. Residual stress analysis in thick uranium films

    International Nuclear Information System (INIS)

    Hodge, A.M.; Foreman, R.J.; Gallegos, G.F.

    2005-01-01

    Residual stress analysis was performed on thick, 1-25 μm, depleted uranium (DU) films deposited on an Al substrate by magnetron sputtering. Two distinct characterization techniques were used to measure substrate curvature before and after deposition. Stress evaluation was performed using the Benabdi/Roche equation, which is based on beam theory of a bi-layer material. The residual stress evolution was studied as a function of coating thickness and applied negative bias voltage (0, -200, -300 V). The stresses developed were always compressive; however, increasing the coating thickness and applying a bias voltage presented a trend towards more tensile stresses and thus an overall reduction of residual stresses

  7. Radiographic follow-up study of Little Leaguer's shoulder

    International Nuclear Information System (INIS)

    Kanematsu, Yoshiji; Iwase, Takenobu; Matsuura, Tetsuya; Suzue, Naoto; Sairyo, Koichi; Kashiwaguchi, Shinji; Iwame, Toshiyuki

    2015-01-01

    Little Leaguer's shoulder is a syndrome involving the proximal humeral epiphyseal plate. Conservative treatment usually resolves the symptoms. However, there are no reports of a radiographic follow-up study of this disease. The purpose of this study was to show the radiographic healing process of Little Leaguer's shoulder. A total of 19 male baseball players diagnosed as having Little Leaguer's shoulder were retrospectively evaluated. The mean age at first presentation was 12.7 years. External rotation anteroposterior radiographs of the shoulder were taken. All patients were treated with rest from throwing, and no throwing was recommended until remodeling was confirmed. Follow-up radiographs were taken at 1-month intervals to assess healing. All patients were observed until healing was confirmed radiographically, after which they returned to baseball. The mean follow-up period was 8.5 months. In addition to radiography, patients were asked whether they had any symptoms and whether they had been able to return to baseball. At the first examination, radiographs showed a wider epiphyseal plate of the throwing side compared with the asymptomatic contralateral shoulder. Healing was observed in all cases. Healing occurred first along the medial side and was then extended laterally. The mean time required for healing was 4.7 months. All patients were able to return to playing baseball at their pre-injury level of play and were asymptomatic when examined at the final follow-up. The healing process of Little Leaguer's shoulder advanced from medial to lateral, and healing was achieved about 5 months after initial examination. (orig.)

  8. Radiographic findings in tuberculosis of the calvarium

    Energy Technology Data Exchange (ETDEWEB)

    Patankar, T.; Varma, R.; Krishnan, A.; Prasad, S. [Dept. of Radiology, King Edward Memorial Hospital, Parel, Bombay (India); Desai, K. [Dept. of Neurosurgery, King Edward Memorial Hospital, Bombay (India); Castillo, M. [Dept. of Radiology, University of North Carolina School of Medicine, Chapel Hill, NC (United States)

    2000-07-01

    We reviewed the pattern of involvement of the calvarium by tuberculosis (TB) in five patients and the role of imaging in its management. Four patients presented with localised scalp swelling and one with generalized seizures. Radiographs revealed lucent lesions with minimal surrounding sclerosis in the frontal (2), parietal (2) and occipital (1) bones. CT showed lesions involving the entire thickness of the calvarium and accompanying contrast-enhancing soft tissue. The patient presenting with seizures had a ring-enhancing lesion in the parietal lobe in addition to the extra-axial lesions. Although radiographs in all cases demonstrated calvarial TB, CT showed the extent of the defect, involvement of adjacent soft tissues, and in one case an intra-axial lesion. Radiographs suffice for follow-up of these patients. (orig.)

  9. Does radiographic arthrosis correlate with cartilage pathology in Labrador Retrievers affected by medial coronoid process disease?

    Science.gov (United States)

    Farrell, Michael; Heller, Jane; Solano, Miguel; Fitzpatrick, Noel; Sparrow, Tim; Kowaleski, Mike

    2014-02-01

    To compare radiographic elbow arthrosis with arthroscopic cartilage pathology in Labrador retrievers with elbow osteoarthritis secondary to medial coronoid process (MCP) disease. Retrospective epidemiological study. Labrador retrievers (n = 317; 592 elbow joints). Data were collected retrospectively (June 2007-June 2011) to identify Labrador retrievers with thoracic limb lameness and elbow pain, a complete set of elbow radiographs, and a comprehensive arthroscopic surgery report. Each radiograph was scored for osteophytosis on the anconeal process and ulnar subtrochlear sclerosis using a modification of the International Elbow Working Group (IEWG) scoring system. Elbows affected by traumatic MCP fracture, humeral condylar osteochondrosis, or ununited anconeal process were excluded. The arthroscopic report was used to generate a composite cartilage score (CCS; 0 = normal, 1 = mild, 2 = moderate, 3 = severe) for each elbow joint. Ordinal regression analysis was performed to test the relationship between radiographic arthrosis score and CCS. There was a significant relationship between radiographic elbow arthrosis and CCS (P arthrosis can be used to predict the severity of arthroscopic cartilage pathology in Labrador retrievers affected by MCP disease. © Copyright 2014 by The American College of Veterinary Surgeons.

  10. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Tofe, A.J.

    1976-01-01

    A stable radiographic scanning agent on a sup(99m)Tc basis has been developed. The substance contains a pertechnetate reduction agent, tin(II)-chloride, chromium(II)-chloride, or iron(II)-sulphate, as well as an organospecific carrier and ascorbic acid or a pharmacologically admissible salt or ester of ascorbic acid. (VJ) [de

  11. Radiographic Assessment of Dental Maturation in Children With Dental Agenesis.

    Science.gov (United States)

    Medina, Aida Carolina; Pozo, Rodrigo Del; de Cedres, Lucila Blanco

    Dental agenesis is the most common developmental anomaly in humans, frequently associated with disorders in dental development and maturation. The purpose of this study is to determine radiographic variations in dental maturation in a group of Venezuelan children with dental agenesis. 1,188 panoramic radiographs, from healthy patients ages 5 to 12 years old were studied for agenesis of permanent teeth. Dental maturation was assessed by relative eruption and dental age according to Nolla, comparing children affected with dental agenesis to a stratified control group selected from the same population, excluding children with premature loss of primary teeth in the left quadrants and unclear radiographs. Descriptive analysis, and differences between means and medians (Student t test, Kruskall-Wallis p=0.05) were performed. Medians for Nolla stages were similar between groups, with delay in tooth formation in the agenesis group for second molars (p<0.05) and maxillary lateral incisors and second premolars. Dental age was significantly underestimated for both groups, -0.89 (±0.78) for the control group and -1.20 (±0.95) for the study group. Tooth eruption was similar between groups. Dental age was significantly delayed in Venezuelan children with dental agenesis, with variable significance for tooth formation of studied teeth.

  12. Standardization of thorax, skull and pelvis radiographic images

    International Nuclear Information System (INIS)

    Pina, D.R.; Ghilardi Netto, T.; Trad, C.S.; Brochi, M.A. Corte; Duarte, S.B.; Pina, S.R.

    2001-01-01

    The radiographic techniques for production of chest, skull and pelvis exam were determined for the standard patient. These techniques produced the quality image with smaller dose, for a standard patient, at any conventional X-ray equipment. The radiographic contrast produced for these techniques was measured utilizing the realistic-analytic phantom and classified as an ideal radiographic contrast. This work has the aim to keep the standard of the quality image, for any thickness of patients usually found in clinic routine of the radiodiagnosis service, satisfying the relation risk-benefit for the patient and cost- benefit for the institution. (author)

  13. Stress Analysis of Composites.

    Science.gov (United States)

    1981-01-01

    8217, Finite Elements in Nonlinear Mechanics, 1., 109-130, Tapir Publishers, Norway (1978). 9. A.J. Barnard and P.W. Sharman, ’Elastic-Plastic Analysis Using...Hybrid Stress Finite Elements,’ Finite Elements in Nonlinear Mechanics, 1, 131-148, Tapir Publishers Norway, (1978). ’.........Pian, ’Variational

  14. Automated computer analysis of x-ray radiographs greatly facilitates measurement of coating-thickness variations in laser-fusion targets

    International Nuclear Information System (INIS)

    Stupin, D.M.; Moore, K.R.; Thomas, G.D.; Whitman, R.L.

    1981-01-01

    An automated system was built to analyze x-ray radiographs of laser fusion targets which greatly facilitates the detection of coating thickness variations. Many laser fusion targets reqire opaque coatings 1 to 20 μm thick which have been deposited on small glass balloons 100 to 500 μm in diameter. These coatings must be uniformly thick to 1% for the targets to perform optimally. Our system is designed to detect variations as small as 100 A in 1-μm-thick coatings by converting the optical density variations of contact x-ray radiographs into coating thickness variations. Radiographic images are recorded in HRP emulsions and magnified by an optical microscope, imaged onto television camera, digitized and processed on a Data General S/230 computer with a code by Whitman. After an initial set-up by the operator, as many as 200 targets will be automatically characterized

  15. Bilateral Chylothorax Due to Blunt Trauma Without Radiographic Evidence of Traumatic Injury

    Directory of Open Access Journals (Sweden)

    Mohamed Mohamed

    2017-03-01

    Full Text Available Chylothorax represents an uncommon clinical entity with multiple etiologies. Chylothorax following blunt thoracic trauma is typically associated with posterior rib fractures or thoracic vertebral fractures or dislocations. The occurrence of a traumatic chylothorax in the absence of associated injuries is a rare event. We report a case of a 51-year-old patient who developed bilateral chylothorax after sustaining blunt trauma without radiographic evidence of traumatic injury. A 51-year-old male presented to the emergency department complaining of progressively worsening shortness of breath and associated chest pain for the prior one week following a fall down several concrete steps. On evaluation, the patient was found to have bilateral pleural effusions with no radiographic evidence of traumatic injury, including posterior rib or thoracic vertebral fractures. Subsequent thoracentesis and pleural fluid analysis were performed confirming the diagnosis of chylothorax. Management included repeated thoracentesis, diet modification and octreotide administration, which resulted in dramatic improvement and eventual resolution of symptoms. Non-iatrogenic traumatic bilateral chylothorax in the absence of other radiographically demonstrated bony or soft tissue injury is a rare event. Chylothorax should be considered in the differential diagnosis of patients presenting with chest pain or shortness of breath following blunt trauma and evidence of pleural effusion, even in the absence of obvious traumatic fracture or injury on radiographic imaging.

  16. Residual stress concerns in containment analysis

    International Nuclear Information System (INIS)

    Costantini, F.; Kulak, R. F.; Pfeiffer, P. A.

    1997-01-01

    The manufacturing of steel containment vessels starts with the forming of flat plates into curved plates. A steel containment structure is made by welding individual plates together to form the sections that make up the complex shaped vessels. The metal forming and welding process leaves residual stresses in the vessel walls. Generally, the effect of metal forming residual stresses can be reduced or virtually eliminated by thermally stress relieving the vesseL In large containment vessels this may not be practical and thus the residual stresses due to manufacturing may become important. The residual stresses could possibly tiect the response of the vessel to internal pressurization. When the level of residual stresses is significant it will affect the vessel's response, for instance the yielding pressure and possibly the failure pressure. The paper will address the effect of metal forming residual stresses on the response of a generic pressure vessel to internal pressurization. A scoping analysis investigated the effect of residual forming stresses on the response of an internally pressurized vessel. A simple model was developed to gain understanding of the mechanics of the problem. Residual stresses due to the welding process were not considered in this investigation

  17. Development of low-silver radiographic detectors

    International Nuclear Information System (INIS)

    Troitskij, V.A.; Novikov, I.A.; Nikitin, V.F.; Krasnyj-Admoni, L.V.; Valevich, M.I.; Belyj, N.G.; Grom, V.S.

    1988-01-01

    The results of investigations on radiographic testing of welded joints of St20, 08Kh18N10T steels, the AMG-6 alloy, copper, titanium using radiographic detectors with the low silver content are presented. The roentgenographic and photographic paper, as well as the samples of experimental films with heavy elements in the photolayer are tested using intensifying screens of different types. Experimental films containing silver 2 times as less as standard X-ray films are shown to provide the similar sensitivity of testing under equal conditions, but the exposure time is two times higher. Prints on the radiophotographic paper in quality and exposure time approach to prints obtained on the RT-1 film containing silver 10 times less than that in the roentgenographic film. The exposure time of the radiographic paper is several times less than that of the ''unibrom'' contrast paper. The testing sensitivity decreases to some extent in this case

  18. The screening pelvic radiograph in pediatric trauma

    International Nuclear Information System (INIS)

    Rees, M.J.; Aickin, R.; Kolbe, A.; Teele, R.L.

    2001-01-01

    Background. Pelvic radiographs are routinely obtained in adult trauma to optimise early management. In adults, pelvic fractures are associated with high early transfusion requirement, high injury severity scores and an increased incidence of other abdominal and thoracic injuries. It is unclear whether this holds true in children. Objective. To determine whether the screening pelvic radiograph is necessary in paediatric trauma. Materials and methods. The notes of all patients who presented after trauma to the Starship Children's Hospital and were triaged to the resuscitation room during 1997 were reviewed. Results of initial radiography were obtained and correlated with later imaging. Results. Our review of 444 injured children seen over a period of 1 year revealed that of 347 children who had screening pelvic radiographs, only 1 had a pelvic fracture. The fracture in this child was clinically apparent and required no specific treatment. Conclusions. The presence of a pelvic fracture is rare in injured children. By omitting screening pelvic radiographs there are potential benefits, including reduced radiation exposure to children and cost savings. Uninterpretable or abnormal clinical examination or haematuria requires further investigation, but routine screening for pelvic fracture is unnecessary. (orig.)

  19. Radiographic evaluation and unusual bone formations in different genetic patterns in synpolydactyly

    International Nuclear Information System (INIS)

    Yucel, Aylin; Acar, Murat; Kuru, Ilhami; Bozan, M. Eray; Solak, Mustafa

    2005-01-01

    To compare the radiological findings of heterozygous and homozygous subjects with synpolydactyly (SPD) and to discuss their unusual bone formations. Families with hand and foot SPD were examined. Genetic analysis was performed with blood samples and the pedigree was constructed. The affected individuals, especially those with distinctive phenotypic features, were invited to our orthopaedics clinic for further diagnostic studies. All participants underwent detailed clinical and X-ray examinations. Of the invited patients, 16 (five female and 11 male; age range 4-37 years, mean age 10.75 years) were included in our study, and hand and foot radiographs were obtained. All subjects had bilateral hand radiographs (32 hands), and 14 had bilateral foot radiographs (28 feet). Genetic analysis revealed 12 heterozygote (75%) and four (25%) homozygote phenotypes. Among patients enrolled into the study nine (three homozygotes, six heterozygotes) had SPD of both hands and feet bilaterally (tetrasynpolydactyly). Six unusual bone formations were observed in the hands and feet: delta phalanx, delta metacarpal/metatarsal, kissing delta phalanx, true double epiphysis, pseudoepiphysis and cone-shaped epiphysis. There were major differences in radiological and clinical manifestations of homozygote and heterozygote phenotypes. The homozygous SPD presented with very distinctive unusual bone formations. The existence and variety of unusual bones may indicate the severity of penetrance and expressivity of SPD. (orig.)

  20. The significance of conventional radiographic parameters in the diagnosis of scapholunate ligament lesions

    Energy Technology Data Exchange (ETDEWEB)

    Megerle, Kai; Poehlmann, S.; Kloeters, O. [Plastic and Hand Surgery, University of Heidelberg, Department of Hand-, Plastic and Reconstructive Surgery - Burn Center -, BG-Trauma Center Ludwigshafen, Ludwigshafen (Germany); Germann, G. [Clinic for Plastic, Reconstructive and Aesthetic Surgery and Preventive Medicine, Heidelberg University Hospital, Ethianum Heidelberg, Ludwigshafen (Germany); Sauerbier, M. [Academic Hospital, University of Frankfurt/Main, Department for Plastic, Hand and Reconstructive Surgery, Main-Taunus Private Clinic, Baden Soden (Germany)

    2011-01-15

    Although in widespread clinical use, evidence of the diagnostic accuracy of radiographic parameters for the diagnosis of scapholunate ligament injuries is scarce. The objective of this study was to evaluate the scapholunate (SL) angle, radiolunate (RL) angle and SL gap as diagnostic parameters for these lesions. Eight hundred forty nine patients, who underwent wrist arthroscopy at our institution because of wrist pain were included in a retrospective analysis. In all patients the SL angle, RL angle and SL gap were measured on preoperative radiographs. These parameters were correlated with the actual finding of the SL ligament during arthroscopy. Optimal test thresholds were calculated as well as sensitivity, specificity and the likelihood ratios of each parameter. All three parameters proved useful in statistical analysis. The optimal cut-off points for diagnosing lesions of the SL ligament were calculated as 62.5 for the SL angle, 12.5 for the RL angle and 2.5 mm for the SL gap. SL angles had the greatest specificity (0.93). We were able to validate plain radiographs as a reliable tool in the work-up of patients with suspected SL ligament injuries. However, wrist arthroscopy remains the gold standard in diagnosing and treating these lesions. (orig.)