WorldWideScience

Sample records for stress perfusion mri

  1. Diagnostic performance of dual-energy CT stress myocardial perfusion imaging: direct comparison with cardiovascular MRI.

    Science.gov (United States)

    Ko, Sung Min; Song, Meong Gun; Chee, Hyun Kun; Hwang, Hweung Kon; Feuchtner, Gudrun Maria; Min, James K

    2014-12-01

    The purpose of this study was to assess the diagnostic performance of stress perfusion dual-energy CT (DECT) and its incremental value when used with coronary CT angiography (CTA) for identifying hemodynamically significant coronary artery disease. One hundred patients with suspected or known coronary artery disease without chronic myocardial infarction detected with coronary CTA underwent stress perfusion DECT, stress cardiovascular perfusion MRI, and invasive coronary angiography (ICA). Stress perfusion DECT and cardiovascular stress perfusion MR images were used for detecting perfusion defects. Coronary CTA and ICA were evaluated in the detection of ≥50% coronary stenosis. The diagnostic performance of coronary CTA for detecting hemo-dynamically significant stenosis was assessed before and after stress perfusion DECT on a per-vessel basis with ICA and cardiovascular stress perfusion MRI as the reference standard. The performance of stress perfusion DECT compared with cardiovascular stress perfusion MRI on a per-vessel basis in the detection of perfusion defects was sensitivity, 89%; specificity, 74%; positive predictive value, 73%; negative predictive value, 90%. Per segment, these values were sensitivity, 76%; specificity, 80%; positive predictive value, 63%; and negative predictive value, 88%. Compared with ICA and cardiovascular stress perfusion MRI per vessel territory the sensitivity, specificity, positive predictive value, and negative predictive value of coronary CTA were 95%, 61%, 61%, and 95%. The values for stress perfusion DECT were 92%, 72%, 68%, and 94%. The values for coronary CTA and stress perfusion DECT were 88%, 79%, 73%, and 91%. The ROC AUC increased from 0.78 to 0.84 (p=0.02) with the use of coronary CTA and stress perfusion DECT compared with coronary CTA alone. Stress perfusion DECT plays a complementary role in enhancing the accuracy of coronary CTA for identifying hemodynamically significant coronary stenosis.

  2. Study of Nicorandil stress perfusion MRI in diagnosing ischemic heart disease

    International Nuclear Information System (INIS)

    Tateishi, Toshiki; Iwai, Mitsuhiro; Takeda, Soji; Hayashi, Ryuji

    2006-01-01

    The excellent spatial resolution of myocardial stress perfusion magnetic resonance imaging is effective for the diagnosis of ischemic heart disease. When dipyridamole or adenosine triphosphate is used as a pharmacological stress in cardiac MRI, non-magnetic instruments are required for infusion of these drugs in a MRI room. We attempted to use nicorandil as a pharmacological stressor. Nicorandil exhibited KATP channel opening and nitrate effects, and could be infused without any special instruments. Based on the coronary artery stenosis assessed by coronary angiography, according to the criteria of the American Heart Association (AHA), the sensitivity, specificity and diagnostic accuracy of nicorandil perfusion MRI for the detection of coronary artery stenosis was 85%, 57% and 74.3%, respectively. No major side effects were observed, except for mild hypotension (mean 10 mmHg) after infusion of the drug. It was concluded that myocardial perfusion MRI examination using nicorandil could be performed non-invasively and safely for the evaluation of coronary vessel disease in patients. (author)

  3. Myocardial perfusion quantification using simultaneously acquired 13 NH3 -ammonia PET and dynamic contrast-enhanced MRI in patients at rest and stress.

    Science.gov (United States)

    Kunze, Karl P; Nekolla, Stephan G; Rischpler, Christoph; Zhang, Shelley HuaLei; Hayes, Carmel; Langwieser, Nicolas; Ibrahim, Tareq; Laugwitz, Karl-Ludwig; Schwaiger, Markus

    2018-04-19

    Systematic differences with respect to myocardial perfusion quantification exist between DCE-MRI and PET. Using the potential of integrated PET/MRI, this study was conceived to compare perfusion quantification on the basis of simultaneously acquired 13 NH 3 -ammonia PET and DCE-MRI data in patients at rest and stress. Twenty-nine patients were examined on a 3T PET/MRI scanner. DCE-MRI was implemented in dual-sequence design and additional T 1 mapping for signal normalization. Four different deconvolution methods including a modified version of the Fermi technique were compared against 13 NH 3 -ammonia results. Cohort-average flow comparison yielded higher resting flows for DCE-MRI than for PET and, therefore, significantly lower DCE-MRI perfusion ratios under the common assumption of equal arterial and tissue hematocrit. Absolute flow values were strongly correlated in both slice-average (R 2  = 0.82) and regional (R 2  = 0.7) evaluations. Different DCE-MRI deconvolution methods yielded similar flow result with exception of an unconstrained Fermi method exhibiting outliers at high flows when compared with PET. Thresholds for Ischemia classification may not be directly tradable between PET and MRI flow values. Differences in perfusion ratios between PET and DCE-MRI may be lifted by using stress/rest-specific hematocrit conversion. Proper physiological constraints are advised in model-constrained deconvolution. © 2018 International Society for Magnetic Resonance in Medicine.

  4. Altered resting-state functional connectivity in post-traumatic stress disorder: a perfusion MRI study

    Science.gov (United States)

    Li, Baojuan; Liu, Jian; Liu, Yang; Lu, Hong-Bing; Yin, Hong

    2013-03-01

    The majority of studies on posttraumatic stress disorder (PTSD) so far have focused on delineating patterns of activations during cognitive processes. Recently, more and more researches have started to investigate functional connectivity in PTSD subjects using BOLD-fMRI. Functional connectivity analysis has been demonstrated as a powerful approach to identify biomarkers of different brain diseases. This study aimed to detect resting-state functional connectivity abnormities in patients with PTSD using arterial spin labeling (ASL) fMRI. As a completely non-invasive technique, ASL allows quantitative estimates of cerebral blood flow (CBF). Compared with BOLD-fMRI, ASL fMRI has many advantages, including less low-frequency signal drifts, superior functional localization, etc. In the current study, ASL images were collected from 10 survivors in mining disaster with recent onset PTSD and 10 survivors without PTSD. Decreased regional CBF in the right middle temporal gyrus, lingual gyrus, and postcentral gyrus was detected in the PTSD patients. Seed-based resting-state functional connectivity analysis was performed using an area in the right middle temporal gyrus as region of interest. Compared with the non-PTSD group, the PTSD subjects demonstrated increased functional connectivity between the right middle temporal gyrus and the right superior temporal gyrus, the left middle temporal gyrus. Meanwhile, decreased functional connectivity between the right middle temporal gyrus and the right postcentral gyrus, the right superior parietal lobule was also found in the PTSD patients. This is the first study which investigated resting-state functional connectivity in PTSD using ASL images. The results may provide new insight into the neural substrates of PTSD.

  5. Diagnostic performance of coronary CT angiography, stress dual-energy CT perfusion, and stress perfusion single-photon emission computed tomography for coronary artery disease: Comparison with combined invasive coronary angiography and stress perfusion cardiac MRI

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hyun Woo; Ko, Sung Min; Hwang, Hweung Kon; So, Young; Yi, Jeong Geun [Konkuk University Medical Center, Research Institute of Biomedical Science, Konkuk University School of Medicine, Seoul (Korea, Republic of); Lee, Eun Jeong [Dept. of Nuclear Medicine, Seoul Medical Center, Seoul (Korea, Republic of)

    2017-06-15

    To investigate the diagnostic performance of coronary computed tomography angiography (CCTA), stress dual-energy computed tomography perfusion (DE-CTP), stress perfusion single-photon emission computed tomography (SPECT), and the combinations of CCTA with myocardial perfusion imaging (CCTA + DE-CTP and CCTA + SPECT) for identifying coronary artery stenosis that causes myocardial hypoperfusion. Combined invasive coronary angiography (ICA) and stress perfusion cardiac magnetic resonance (SP-CMR) imaging are used as the reference standard. We retrospectively reviewed the records of 25 patients with suspected coronary artery disease, who underwent CCTA, DE-CTP, SPECT, SP-CMR, and ICA. The reference standard was defined as ≥ 50% stenosis by ICA, with a corresponding myocardial hypoperfusion on SP-CMR. For per-vascular territory analysis, the sensitivities of CCTA, DE-CTP, SPECT, CCTA + DE-CTP, and CCTA + SPECT were 96, 96, 68, 93, and 68%, respectively, and specificities were 72, 75, 89, 85, and 94%, respectively. The areas under the receiver operating characteristic curve (AUCs) were 0.84 ± 0.05, 0.85 ± 0.05, 0.79 ± 0.06, 0.89 ± 0.04, and 0.81 ± 0.06, respectively. For per-patient analysis, the sensitivities of CCTA, DE-CTP, SPECT, CCTA + DE-CTP, and CCTA + SPECT were 100, 100, 89, 100, and 83%, respectively; the specificities were 14, 43, 57, 43, and 57%, respectively; and the AUCs were 0.57 ± 0.13, 0.71 ± 0.11, 0.73 ± 0.11, 0.71 ± 0.11, and 0.70 ± 0.11, respectively. The combination of CCTA and DE-CTP enhances specificity without a loss of sensitivity for detecting hemodynamically significant coronary artery stenosis, as defined by combined ICA and SP-CMR.

  6. High-resolution MRI for the quantitative evaluation of subendocardial and subepicardial perfusion under pharmalogical stress and at rest

    International Nuclear Information System (INIS)

    Ritter, C.O.; Savio, K. del; Brackertz, A.; Beer, M.; Hahn, D.; Koestler, H.

    2007-01-01

    Purpose: MR stress perfusion imaging of the heart allows the quantification of myocardial perfusion and the evaluation of myocardial perfusion reserve (MPR) and the ratio of subendocardial to subepicardial perfusion at rest and under adenosine stress. The aim of this study was to evaluate a high-resolution GRAPPA sequence for quantitative MR first pass perfusion imaging in healthy volunteers. Materials and Methods: First pass stress and rest perfusion studies were performed on 10 healthy volunteers using a 1.5 T MR scanner with a multislice SR-TrueFISP first pass perfusion sequence with a GRAPPA algorithm (acceleration factor 3) in prebolus technique and an image resolution of 1.8 x 1.8 mm. For the comparison group, we examined 12 different healthy volunteers with a standard first pass perfusion SR-TrueFISP sequence using a resolution of 2.7 x 3.3 mm. Myocardial contours were manually delineated followed by an automatic division of the myocardium into two rings with an equal thickness for the subendo- and subepicardial layer. Eight sectors per slice were evaluated using contamination and baseline correction. Results: Using the GRAPPA sequence, the ratio of subendo- to subepimyocardial perfusion was 1.18 ± 0.32 for the examination at rest. Under pharmacologically induced stress, the ratio was 1.08 ± 0.27. For the standard sequence the ratio was 1.15 ± 0.28 at rest and 1.11 ± 0.33 under stress. For the high resolution sequence higher mean values for the subendo- to subepimyocardial ratio were obtained with comparable standard deviations. The difference between the sequences was not significant. Conclusion: The evaluation of subendomyocardial and subepimyocardial perfusion is feasible with a high-resolution first pass perfusion sequence. The use of a higher resolution to avoid systematic error leads to increased image noise. However, no relevant reduction in the quantitative perfusion values under stress and at rest was able to be depicted. (orig.)

  7. Automatic assessment of cardiac perfusion MRI

    DEFF Research Database (Denmark)

    Ólafsdóttir, Hildur; Stegmann, Mikkel Bille; Larsson, Henrik B.W.

    2004-01-01

    In this paper, a method based on Active Appearance Models (AAM) is applied for automatic registration of myocardial perfusion MRI. A semi-quantitative perfusion assessment of the registered image sequences is presented. This includes the formation of perfusion maps for three parameters; maximum up...

  8. Quantitative lung perfusion evaluation using Fourier decomposition perfusion MRI.

    Science.gov (United States)

    Kjørstad, Åsmund; Corteville, Dominique M R; Fischer, Andre; Henzler, Thomas; Schmid-Bindert, Gerald; Zöllner, Frank G; Schad, Lothar R

    2014-08-01

    To quantitatively evaluate lung perfusion using Fourier decomposition perfusion MRI. The Fourier decomposition (FD) method is a noninvasive method for assessing ventilation- and perfusion-related information in the lungs, where the perfusion maps in particular have shown promise for clinical use. However, the perfusion maps are nonquantitative and dimensionless, making follow-ups and direct comparisons between patients difficult. We present an approach to obtain physically meaningful and quantifiable perfusion maps using the FD method. The standard FD perfusion images are quantified by comparing the partially blood-filled pixels in the lung parenchyma with the fully blood-filled pixels in the aorta. The percentage of blood in a pixel is then combined with the temporal information, yielding quantitative blood flow values. The values of 10 healthy volunteers are compared with SEEPAGE measurements which have shown high consistency with dynamic contrast enhanced-MRI. All pulmonary blood flow (PBF) values are within the expected range. The two methods are in good agreement (mean difference = 0.2 mL/min/100 mL, mean absolute difference = 11 mL/min/100 mL, mean PBF-FD = 150 mL/min/100 mL, mean PBF-SEEPAGE = 151 mL/min/100 mL). The Bland-Altman plot shows a good spread of values, indicating no systematic bias between the methods. Quantitative lung perfusion can be obtained using the Fourier Decomposition method combined with a small amount of postprocessing. Copyright © 2013 Wiley Periodicals, Inc.

  9. Perfusion MRI in CNS disease: current concepts

    International Nuclear Information System (INIS)

    Essig, M.; Giesel, F.; Le-Huu, M.; Stieltjes, B.; Tengg, H. von; Weber, M.-A.

    2004-01-01

    Today there are several indications for cerebral perfusion MRI. The major indications routinely used in increasing numbers of imaging centers include cerebrovascular disease, tumor imaging and recently psychiatric disorders. Perfusion MRI is based on the injection of a gadolinium chelate and the rapid acquisition of images as the bolus of contrast agent passes through the blood vessels in the brain. The contrast agent causes a signal change; this signal change over time can be analysed to measure cerebral hemodynamics. The quality of brain perfusion studies is very dependent on the contrast agent used: a robust and strong signal decrease with a compact bolus is needed. MultiHance (gadobenate dimeglumine, Gd-BOPTA) is the first of a new class of paramagnetic MR contrast agents with a weak affinity for serum proteins. Due to the interaction of Gd-BOPTA with serum albumin, MultiHance presents with significantly higher T1- and T2-relaxivities enabling a sharper bolus profile. This article reviews the indications of perfusion MRI and the performance of MultiHance in MR perfusion of different diseases. Previous studies using perfusion MRI for a variety of purposes required the use of double dose of contrast agent to achieve a sufficiently large signal drop to enable the acquisition of a clear input function and the calculation of perfusion rCBV and rCBF maps of adequate quality. Recent studies with Multi-Hance suggest that only a single dose of this agent is needed to cause a signal drop of about 30% which is sufficient to allow the calculation of high quality rCBV and rCBF maps. (orig.)

  10. MRI of pulmonary perfusion; MRT der Lungenperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Fink, C. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen (Germany). Institut fuer Klinische Radiologie; Deutsches Krebsforschungszentrum (DKFZ), Abteilung Radiologie, Heidelberg (Germany); Risse, F.; Semmler, W. [Deutsches Krebsforschungszentrum (DKFZ), Abteilung Medizinische Physik in der Radiologie, Heidelberg (Germany); Schoenberg, S.O.; Reiser, M.F. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen (Germany). Institut fuer Klinische Radiologie; Kauczor, H.-U. [Deutsches Krebsforschungszentrum (DKFZ), Abteilung Radiologie, Heidelberg (Germany)

    2006-04-15

    Lung perfusion is a crucial prerequisite for effective gas exchange. Quantification of pulmonary perfusion is important for diagnostic considerations and treatment planning in various diseases of the lungs. Besides disorders of pulmonary vessels such as acute pulmonary embolism and pulmonary hypertension, these also include diseases of the respiratory tract and lung tissue as well as pulmonary tumors. This contribution presents the possibilities and technical requirements of MRI for diagnostic work-up of pulmonary perfusion. (orig.) [German] Die Perfusion der Lunge ist eine entscheidende Voraussetzung fuer einen effektiven Gasaustausch. Die Bestimmung der Lungenperfusion ist bei verschiedenen Erkrankungen der Lunge fuer Diagnostik und Therapieplanung bedeutsam. Hierzu zaehlen neben Erkrankungen der Lungengefaesse wie akute Lungenembolie und pulmonale Hypertension ebenso Erkrankungen der Atemwege, des Lungengeruests und Lungentumoren. In diesem Beitrag werden die Moeglichkeiten und technischen Voraussetzungen der MRT zur Diagnostik der Lungenperfusion dargestellt. (orig.)

  11. Myocardial perfusion modeling using MRI

    DEFF Research Database (Denmark)

    Larsson, H B; Fritz-Hansen, T; Rostrup, Egill

    1996-01-01

    In the present study, it is shown that it is possible to quantify myocardial perfusion using magnetic resonance imaging in combination with gadolinium diethylenetriaminopentaacetic acid (Gd-DTPA). Previously, a simple model and method for measuring myocardial perfusion using an inversion recovery...... turbo-FLASH (fast low-angle shot) sequence and Gd-DTPA has been presented. Here, an extension of the model is presented taking into account fast and slow water exchange between the compartments, enabling the calculation of the unidirectional influx constant (Ki) for Gd-DTPA, the distribution volume...... of Gd-DTPA (lambda), the vascular blood volume (Vb), and the time delay through the coronary arteries (delta T). The model was evaluated by computer simulation and used on experimental results from seven healthy subjects. The results in the healthy volunteers for a region of interest placed...

  12. Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Feger, S.; Rief, M.; Zimmermann, E.; Richter, F.; Roehle, R. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Dewey, M. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Institut fuer Radiologie, Berlin (Germany); Schoenenberger, E. [Medizinische Hochschule Hannover, Department of Medicine, Hannover (Germany)

    2015-07-15

    To evaluate patient acceptance of noninvasive imaging tests for detection of coronary artery disease (CAD), including single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI), stress perfusion magnetic resonance imaging (MRI), coronary CT angiography (CTA) in combination with CT myocardial stress perfusion (CTP), and conventional coronary angiography (CCA). Intraindividual comparison of perception of 48 patients from the CORE320 multicentre multinational study who underwent rest and stress SPECT-MPI with a technetium-based tracer, combined CTA and CTP (both with contrast agent, CTP with adenosine), MRI, and CCA. The analysis was performed by using a validated questionnaire. Patients had significantly more concern prior to CCA than before CTA/CTP (p < 0.001). CTA/CTP was also rated as more comfortable than SPECT-MPI (p = 0.001). Overall satisfaction with CT was superior to that of MRI (p = 0.007). More patients preferred CT (46 %; p < 0.001) as a future diagnostic test. Regarding combined CTA/CTP, CTP was characterised by higher pain levels and an increased frequency of angina pectoris during the examination (p < 0.001). Subgroup analysis showed a higher degree of pain during SPECT-MPI with adenosine stress compared to physical exercise (p = 0.016). All noninvasive cardiac imaging tests are well accepted by patients, with CT being the preferred examination. (orig.)

  13. Comparison with myocardial perfusion MRI and myocardial perfusion SPECT in the diagnostic performance of coronary artery disease. A meta-analysis

    International Nuclear Information System (INIS)

    Iwata, Kunihiro; Kubota, Makoto; Ogasawara, Katsuhiko

    2008-01-01

    We compared the diagnostic abilities of stress myocardial perfusion MRI (myocardial perfusion MRI) and myocardial perfusion single photon emission computed tomography (SPECT), using a meta-analysis method. We investigated the diagnostic abilities of MRI and SPECT in similar subject groups in reports written in English or Japanese. The reports to be used for analysis were selected according to a ''screening standard,'' which was established in advance. After consolidating the data from the selected reports, we compared the integrated odds ratio, the point estimation values of sensibility/specificity, and the summary receiver operating characteristic (ROC) curve. For the analysis, six reports were selected (subjects: 153, coronary-artery target sites: 447). Meta-analysis revealed that the diagnostic ability of myocardial perfusion MRI was superior to that of myocardial perfusion SPECT regarding each of the parameters. This is considered to be supportive evidence of the usefulness of myocardial perfusion MRI. (author)

  14. The additional value of first pass myocardial perfusion imaging during peak dose of dobutamine stress cardiac MRI for the detection of myocardial ischemia

    NARCIS (Netherlands)

    Lubbers, Daniel D.; Janssen, Caroline H. C.; Kuijpers, Dirkjan; Van Dijkman, Paul R. M.; Overbosch, Jelle; Willems, Tineke P.; Oudkerk, Matthijs

    Purpose of this study was to assess the additional value of first pass myocardial perfusion imaging during peak dose of dobutamine stress Cardiac-MR (CMR). Dobutamine Stress CMR was performed in 115 patients with an inconclusive diagnosis of myocardial ischemia on a 1.5 T system (Magnetom Avanto,

  15. Improved visualization of delayed perfusion in lung MRI

    International Nuclear Information System (INIS)

    Risse, Frank; Eichinger, Monika; Kauczor, Hans-Ulrich; Semmler, Wolfhard; Puderbach, Michael

    2011-01-01

    Introduction: The investigation of pulmonary perfusion by three-dimensional (3D) dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) was proposed recently. Subtraction images are generated for clinical evaluation, but temporal information is lost and perfusion defects might therefore be masked in this process. The aim of this study is to demonstrate a simple analysis strategy and classification for 3D-DCE-MRI perfusion datasets in the lung without omitting the temporal information. Materials and methods: Pulmonary perfusion measurements were performed in patients with different lung diseases using a 1.5 T MR-scanner with a time-resolved 3D-GRE pulse sequence. 25 3D-volumes were acquired after iv-injection of 0.1 mmol/kg KG Gadolinium-DTPA. Three parameters were determined for each pixel: (1) peak enhancement S n,max normalized to the arterial input function to detect regions of reduced perfusion; (2) time between arterial peak enhancement in the large pulmonary artery and tissue peak enhancement τ to visualize regions with delayed bolus onset; and (3) ratio R = S n,max /τ was calculated to visualize impaired perfusion, irrespectively of whether related to reduced or delayed perfusion. Results: A manual selection of peak perfusion images is not required. Five different types of perfusion can be found: (1) normal perfusion; (2) delayed non-reduced perfusion; (3) reduced non-delayed perfusion; (4) reduced and delayed perfusion; and (5) no perfusion. Types II and IV could not be seen in subtraction images since the temporal information is necessary for this purpose. Conclusions: The analysis strategy in this study allows for a simple and observer-independent visualization and classification of impaired perfusion in dynamic contrast-enhanced pulmonary perfusion MRI by using the temporal information of the datasets.

  16. Non-contrast MRI perfusion angiosome in diabetic feet

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Jie [Cardiovascular Imaging Lab, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Hastings, Mary K.; Mueller, Michael J. [Washington University School of Medicine, The Program in Physical Therapy, St. Louis, MO (United States); Muccigross, David; Hildebolt, Charles F. [Washington University School of Medicine, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Fan, Zhaoyang [Cedars-Sinai Medical Center, Biomedical Imaging Research Institute, Los Angeles, CA (United States); Gao, Fabao [West China Hospital, Sichuan University, Department of Radiology, Chengdu (China); Curci, John [Washington University School of Medicine, The Department of Surgery, St. Louis, MO (United States)

    2015-01-15

    The purpose of this study is to develop a non-contrast magnetic resonance imaging (MRI) approach to evaluate skeletal muscle perfusion in the diabetic foot based on the concept of angiosomes of the foot. Five healthy volunteers and five participants with diabetes (HbA1c = 7.2 ± 1.8 %) without a history of peripheral artery disease were examined. The non-contrast perfusion measurements were performed during a toe flexion challenge. Absolute perfusion maps were created and two regions (medial and lateral) on the maps were segmented based on angiosomes. Regional difference in the perfusion of foot muscle was readily visualized in the MRI perfusion angiosomes during the challenge. In the participants with diabetes, the perfusion during toe flexion challenge was significantly lower than in healthy volunteers (P < 0.01). The average perfusion for the medial plantar region of the right foot was lower in subjects with diabetes (38 ± 9 ml/min/100 g) than in healthy subjects (93 ± 33 ml/min/100 g). Non-contrast MRI perfusion angiosome maps demonstrate the feasibility of determining regional perfusion in foot muscles during toe challenge and may facilitate evaluation of muscle perfusion in diabetic feet. (orig.)

  17. Non-contrast MRI perfusion angiosome in diabetic feet

    International Nuclear Information System (INIS)

    Zheng, Jie; Hastings, Mary K.; Mueller, Michael J.; Muccigross, David; Hildebolt, Charles F.; Fan, Zhaoyang; Gao, Fabao; Curci, John

    2015-01-01

    The purpose of this study is to develop a non-contrast magnetic resonance imaging (MRI) approach to evaluate skeletal muscle perfusion in the diabetic foot based on the concept of angiosomes of the foot. Five healthy volunteers and five participants with diabetes (HbA1c = 7.2 ± 1.8 %) without a history of peripheral artery disease were examined. The non-contrast perfusion measurements were performed during a toe flexion challenge. Absolute perfusion maps were created and two regions (medial and lateral) on the maps were segmented based on angiosomes. Regional difference in the perfusion of foot muscle was readily visualized in the MRI perfusion angiosomes during the challenge. In the participants with diabetes, the perfusion during toe flexion challenge was significantly lower than in healthy volunteers (P < 0.01). The average perfusion for the medial plantar region of the right foot was lower in subjects with diabetes (38 ± 9 ml/min/100 g) than in healthy subjects (93 ± 33 ml/min/100 g). Non-contrast MRI perfusion angiosome maps demonstrate the feasibility of determining regional perfusion in foot muscles during toe challenge and may facilitate evaluation of muscle perfusion in diabetic feet. (orig.)

  18. Retrospective respiratory triggering renal perfusion MRI

    Energy Technology Data Exchange (ETDEWEB)

    Attenberger, Ulrike I.; Michaely, Henrik J.; Schoenberg, Stefan O. (Dept. of Clinical Radiology and Nuclear Medicine, Univ. Hospital Mannheim, Univ. of Heidelberg, Mannheim (Germany)), e-mail: ulrike.attenberger@medma.uni-heidelberg.de; Sourbron, Steven P. (Div. of Medical Physics, Univ. of Leeds, Leeds (United Kingdom)); Reiser, Maximilian F. (Dept. of Clinical Radiology, Univ. Hospitals Munich, Grosshadern, Ludwig-Maximilians-Univ., Munich (Germany))

    2010-12-15

    Background: Artifacts of respiratory motion are one of the well-known limitations of dynamic contrast-enhanced MRI (DCE-MRI) of the kidney. Purpose: To propose and evaluate a retrospective triggering approach to minimize the effect of respiratory motion in DCE-MRI of the kidney. Material and Methods: Nine consecutive patients underwent renal perfusion measurements. Data were acquired with a 2D saturation-recovery TurboFLASH sequence. In order to test the dependence of the results on size and location of the manually drawn triggering regions of interest (ROIs), three widely differing triggering regions were defined by one observer. Mean value, standard deviation, and variability of the renal function parameters plasma flow (FP), plasma volume (VP), plasma transit time (TP), tubular flow (FT), tubular volume (VT), and tubular transit time (TT) were calculated on a per-patient basis. Results: The results show that triggered data have adequate temporal resolution to measure blood flow. The overall average values of the function parameters were: 152.77 (FP), 15.18 (VP), 6,73 (TP), 18.50 (FT), 35.36 (VT), and 117.67 (TT). The variability (calculated in % SD from the mean value) for three different respiratory triggering regions defined on a per-patient basis was between 0.81% and 9.87% for FP, 1.45% and 8.19% for VP, 0% and 9.63% for TP, 2.15% and 12.23% for TF, 0.8% and 17.28% for VT, and 1.97% and 12.87% for TT. Conclusion: Triggering reduces the oscillations in the signal curves and produces sharper parametric maps. In contrast to numerically challenging approaches like registration and segmentation it can be applied in clinical routine, but a (semi)-automatic approach to select the triggering ROI is desirable to reduce user dependence.

  19. [MRI methods for pulmonary ventilation and perfusion imaging].

    Science.gov (United States)

    Sommer, G; Bauman, G

    2016-02-01

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O2-enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies.

  20. MRI methods for pulmonary ventilation and perfusion imaging

    International Nuclear Information System (INIS)

    Sommer, G.; Bauman, G.

    2016-01-01

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O 2 -enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies. (orig.) [de

  1. Dynamic contrast enhanced MRI for perfusion quantification

    DEFF Research Database (Denmark)

    Andersen, Irene Klærke

    2002-01-01

    Magnetic resonance imaging, during bolus passage of a paramagnetic contrast agent, is used world-wide to obtain parameters that reflect the pathological state of tissue. Abnormal perfusion occurs in diseases such as stoke and tumour. Consequently, perfusion quantication could have signi cant...... clinical value both in diagnosis and treatment of such pathologies. One approach for perfusion quanti cation involves using the contrast mechanism that a ects the transverse relaxation rates of the magnetization, R2 or R 2 , since this provides the most pronounced effect. However, the linearity between...

  2. Adenosine-stress dynamic real-time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results

    Energy Technology Data Exchange (ETDEWEB)

    Weininger, Markus [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Department of Medicine, Division of Cardiology, Medical University of South Carolina, Charleston, SC (United States); Ramachandra, Ashok [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Fink, Christian [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany); Rowe, Garrett W.; Costello, Philip [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Henzler, Thomas [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany)

    2012-12-15

    Purpose: Recent innovations in CT enable the evolution from mere morphologic imaging to dynamic and functional testing. We describe our initial experience performing myocardial stress perfusion CT in a clinical population with acute chest pain. Methods and materials: Myocardial stress perfusion CT was performed on twenty consecutive patients (15 men, 5 women; mean age 65 ± 8 years) who presented with acute chest pain and were clinically referred for stress/rest SPECT and cardiac MRI. Prior to CT each patient was randomly assigned either to Group A or to Group B in a consecutive order (10 patients per group). Group A underwent adenosine-stress dynamic real-time myocardial perfusion CT using a novel “shuttle” mode on a 2nd generation dual-source CT. Group B underwent adenosine-stress first-pass dual-energy myocardial perfusion CT using the same CT scanner in dual-energy mode. Two experienced observers visually analyzed all CT perfusion studies. CT findings were compared with MRI and SPECT. Results: In Group A 149/170 myocardial segments (88%) could be evaluated. Real-time perfusion CT (versus SPECT) had 86% (84%) sensitivity, 98% (92%) specificity, 94% (88%) positive predictive value, and 96% (92%) negative predictive value in comparison with perfusion MRI for the detection of myocardial perfusion defects. In Group B all myocardial segments were available for analysis. Compared with MRI, dual-energy myocardial perfusion CT (versus SPECT) had 93% (94%) sensitivity, 99% (98%) specificity, 92% (88%) positive predictive value, and 96% (94%) negative predictive value for detecting hypoperfused myocardial segments. Conclusion: Our results suggest the clinical feasibility of myocardial perfusion CT imaging in patients with acute chest pain. Compared to MRI and SPECT both, dynamic real-time perfusion CT and first-pass dual-energy perfusion CT showed good agreement for the detection of myocardial perfusion defects.

  3. Adenosine-stress dynamic real-time myocardial perfusion CT and adenosine-stress first-pass dual-energy myocardial perfusion CT for the assessment of acute chest pain: Initial results

    International Nuclear Information System (INIS)

    Weininger, Markus; Schoepf, U. Joseph; Ramachandra, Ashok; Fink, Christian; Rowe, Garrett W.; Costello, Philip; Henzler, Thomas

    2012-01-01

    Purpose: Recent innovations in CT enable the evolution from mere morphologic imaging to dynamic and functional testing. We describe our initial experience performing myocardial stress perfusion CT in a clinical population with acute chest pain. Methods and materials: Myocardial stress perfusion CT was performed on twenty consecutive patients (15 men, 5 women; mean age 65 ± 8 years) who presented with acute chest pain and were clinically referred for stress/rest SPECT and cardiac MRI. Prior to CT each patient was randomly assigned either to Group A or to Group B in a consecutive order (10 patients per group). Group A underwent adenosine-stress dynamic real-time myocardial perfusion CT using a novel “shuttle” mode on a 2nd generation dual-source CT. Group B underwent adenosine-stress first-pass dual-energy myocardial perfusion CT using the same CT scanner in dual-energy mode. Two experienced observers visually analyzed all CT perfusion studies. CT findings were compared with MRI and SPECT. Results: In Group A 149/170 myocardial segments (88%) could be evaluated. Real-time perfusion CT (versus SPECT) had 86% (84%) sensitivity, 98% (92%) specificity, 94% (88%) positive predictive value, and 96% (92%) negative predictive value in comparison with perfusion MRI for the detection of myocardial perfusion defects. In Group B all myocardial segments were available for analysis. Compared with MRI, dual-energy myocardial perfusion CT (versus SPECT) had 93% (94%) sensitivity, 99% (98%) specificity, 92% (88%) positive predictive value, and 96% (94%) negative predictive value for detecting hypoperfused myocardial segments. Conclusion: Our results suggest the clinical feasibility of myocardial perfusion CT imaging in patients with acute chest pain. Compared to MRI and SPECT both, dynamic real-time perfusion CT and first-pass dual-energy perfusion CT showed good agreement for the detection of myocardial perfusion defects.

  4. Quantification of MRI measured myocardial perfusion reserve in healthy humans: A comparison with positron emission tomography

    DEFF Research Database (Denmark)

    Fritz-Hansen, T.; Hove, J.D.; Kofoed, K.F.

    2008-01-01

    Purpose: To validate a noninvasive quantitative MRI technique, the K-i perfusion method, for myocardial perfusion in humans using N-13-ammonia PET as a reference method. Materials and Methods: Ten healthy males (64 +/- 8 years) were examined with combined PET and MRI perfusion imaging at rest and...

  5. A capillary-based perfusion phantom for simulation of brain perfusion for MRI

    International Nuclear Information System (INIS)

    Maciak, A.; Kronfeld, A.; Mueller-Forell, W.; Wille, C.; Kempski, O.; Stoeter, P.

    2010-01-01

    Purpose: The measurement of the CBF is a non-standardized procedure and there are no reliable gold standards. This abstract shows a capillary-based perfusion-phantom for CE-DSC-MRI. It has equivalent flow properties to those within the tissue capillary system of the human brain and allows the validation of the Siemens Perfusion (MR) software. Materials and Methods: The perfusion phantom consists of a dialyzer for the simulation of the capillary system, a feeding tube for simulation of the AIF and a pulsatile pump for simulation of the heart. Using this perfusion phantom, the exact determination of the gold standard CBF due to the well-known geometry of the phantom is easy. It was validated based on different perfusion measurements. These measurements were investigated with standard software (Siemens Perfusion MR). The software determined the CBF within the capillary system. Based on this CBF, a comparison to the gold standard was made with several different flow speeds. After AIF selection, a total of 726 CBF data points were automatically extracted by the software. Results: This results in a comparison of the gold standard CBF to these 726 CBF values. Therefore, a reproducible and reliable deviation estimation between gold standard CBF and measured CBF using the software was computed. It can be shown that the deviation between gold standard and software-based evaluation ranges between 1 and 31 %. Conclusion: There is no significance for any correlation between flow speed and amount of deviation. The mean measured CBF is 11.4 % higher than the gold standard CBF (p-value < 0.001). Using this kind of perfusion-phantom, the validation of different software systems allows reliable conclusions about their quality. (orig.)

  6. Meta-Analysis of Stress Myocardial Perfusion Imaging

    Science.gov (United States)

    2017-06-06

    Coronary Disease; Echocardiography; Fractional Flow Reserve, Myocardial; Hemodynamics; Humans; Magnetic Resonance Imaging; Myocardial Perfusion Imaging; Perfusion; Predictive Value of Tests; Single Photon Emission Computed Tomography; Positron Emission Tomography; Multidetector Computed Tomography; Echocardiography, Stress; Coronary Angiography

  7. Cardiac function and myocardial perfusion immediately following maximal treadmill exercise inside the MRI room

    Directory of Open Access Journals (Sweden)

    Ballinger Michelle R

    2008-01-01

    Full Text Available Abstract Treadmill exercise stress testing is an essential tool in the prevention, detection, and treatment of a broad spectrum of cardiovascular disease. After maximal exercise, cardiac images at peak stress are typically acquired using nuclear scintigraphy or echocardiography, both of which have inherent limitations. Although CMR offers superior image quality, the lack of MRI-compatible exercise and monitoring equipment has prevented the realization of treadmill exercise CMR. It is critical to commence imaging as quickly as possible after exercise to capture exercise-induced cardiac wall motion abnormalities. We modified a commercial treadmill such that it could be safely positioned inside the MRI room to minimize the distance between the treadmill and the scan table. We optimized the treadmill exercise CMR protocol in 20 healthy volunteers and successfully imaged cardiac function and myocardial perfusion at peak stress, followed by viability imaging at rest. Imaging commenced an average of 30 seconds after maximal exercise. Real-time cine of seven slices with no breath-hold and no ECG-gating was completed within 45 seconds of exercise, immediately followed by stress perfusion imaging of three short-axis slices which showed an average time to peak enhancement within 57 seconds of exercise. We observed a 3.1-fold increase in cardiac output and a myocardial perfusion reserve index of 1.9, which agree with reported values for healthy subjects at peak stress. This study successfully demonstrates in-room treadmill exercise CMR in healthy volunteers, but confirmation of feasibility in patients with heart disease is still needed.

  8. A Unifying model of perfusion and motion applied to reconstruction of sparsely sampled free-breathing myocardial perfusion MRI

    DEFF Research Database (Denmark)

    Pedersen, Henrik; Ólafsdóttir, Hildur; Larsen, Rasmus

    2010-01-01

    The clinical potential of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is currently limited by respiratory induced motion of the heart. This paper presents a unifying model of perfusion and motion in which respiratory motion becomes an integral part of myocardial perfusion...... quantification. Hence, the need for tedious manual motion correction prior to perfusion quantification is avoided. In addition, we demonstrate that the proposed framework facilitates the process of reconstructing DCEMRI from sparsely sampled data in the presence of respiratory motion. The paper focuses primarily...... on the underlying theory of the proposed framework, but shows in vivo results of respiratory motion correction and simulation results of reconstructing sparsely sampled data....

  9. Assessment of pulmonary parenchyma perfusion with FAIR in comparison with DCE-MRI-Initial results

    Energy Technology Data Exchange (ETDEWEB)

    Fan Li [Department of Radiology, ChangZheng Hospital Affiliated to Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003 (China)], E-mail: fanli0930@163.com; Liu Shiyuan [Department of Radiology, ChangZheng Hospital Affiliated to Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003 (China); Sun Fei [GE Healthcare China (China)], E-mail: Fei.sun@med.ge.com; Xiao Xiangsheng [Department of Radiology, ChangZheng Hospital Affiliated to Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003 (China)], E-mail: lizhaobin79@163.com

    2009-04-15

    Objective: The aim of this study was to assess pulmonary parenchyma perfusion with flow-sensitive alternating inversion recovery (FAIR) in comparison with 3D dynamic contrast-enhanced (DCE) imaging in healthy volunteers and in patients with pulmonary embolism or lung cancer. Materials and methods: Sixteen healthy volunteers and 16 patients with pulmonary embolism (5 cases) or lung cancer (11 cases) were included in this study. Firstly, the optimized inversion time of FAIR (TI) was determined in 12 healthy volunteers. Then, FAIR imaging with the optimized TI was performed followed by DCE-MRI on the other 4 healthy volunteers and 16 patients. Tagging efficiency of lung and SNR of perfusion images were calculated with different TI values. In the comparison of FAIR with DCE-MRI, the homogeneity of FAIR and DCE-MRI perfusion was assessed. In the cases of perfusion abnormality, the contrast between normal lung and perfusion defects was quantified by calculating a normalized signal intensity ratio. Results: One thousand milliseconds was the optimal TI, which generated the highest lung tagging efficiency and second highest PBF SNR. In the volunteers, the signal intensity of perfusion images acquired with both FAIR and DCE-MRI was homogeneous. Wedged-shaped or triangle perfusion defects were visualized in five pulmonary embolisms and three lung cancer cases. There was no significant statistical difference in signal intensity ratio between FAIR and DCE-MRI (P > 0.05). In the rest of eight lung cancers, all the lesions showed low perfusion against the higher perfused pulmonary parenchyma in both FAIR and DCE-MRI. Conclusion: Pulmonary parenchyma perfusion imaging with FAIR was feasible, consistent and could obtain similar functional information to that from DCE-MRI.

  10. Assessment of pulmonary parenchyma perfusion with FAIR in comparison with DCE-MRI-Initial results

    International Nuclear Information System (INIS)

    Fan Li; Liu Shiyuan; Sun Fei; Xiao Xiangsheng

    2009-01-01

    Objective: The aim of this study was to assess pulmonary parenchyma perfusion with flow-sensitive alternating inversion recovery (FAIR) in comparison with 3D dynamic contrast-enhanced (DCE) imaging in healthy volunteers and in patients with pulmonary embolism or lung cancer. Materials and methods: Sixteen healthy volunteers and 16 patients with pulmonary embolism (5 cases) or lung cancer (11 cases) were included in this study. Firstly, the optimized inversion time of FAIR (TI) was determined in 12 healthy volunteers. Then, FAIR imaging with the optimized TI was performed followed by DCE-MRI on the other 4 healthy volunteers and 16 patients. Tagging efficiency of lung and SNR of perfusion images were calculated with different TI values. In the comparison of FAIR with DCE-MRI, the homogeneity of FAIR and DCE-MRI perfusion was assessed. In the cases of perfusion abnormality, the contrast between normal lung and perfusion defects was quantified by calculating a normalized signal intensity ratio. Results: One thousand milliseconds was the optimal TI, which generated the highest lung tagging efficiency and second highest PBF SNR. In the volunteers, the signal intensity of perfusion images acquired with both FAIR and DCE-MRI was homogeneous. Wedged-shaped or triangle perfusion defects were visualized in five pulmonary embolisms and three lung cancer cases. There was no significant statistical difference in signal intensity ratio between FAIR and DCE-MRI (P > 0.05). In the rest of eight lung cancers, all the lesions showed low perfusion against the higher perfused pulmonary parenchyma in both FAIR and DCE-MRI. Conclusion: Pulmonary parenchyma perfusion imaging with FAIR was feasible, consistent and could obtain similar functional information to that from DCE-MRI.

  11. Differences in perfusion parameters between upper and lower lumbar vertebral segments with dynamic contrast-enhanced MRI (DCE MRI)

    International Nuclear Information System (INIS)

    Savvopoulou, Vasiliki; Vlahos, Lampros; Moulopoulos, Lia Angela; Maris, Thomas G.

    2008-01-01

    To investigate the influence of age, sex and spinal level on perfusion parameters of normal lumbar bone marrow with dynamic contrast-enhanced MRI (DCE MRI). Sixty-seven subjects referred for evaluation of low back pain or sciatica underwent DCE MRI of the lumbar spine. After subtraction of dynamic images, a region of interest (ROI) was placed on each lumbar vertebral body of all subjects, and time intensity curves were generated. Consequently, perfusion parameters were calculated. Statistical analysis was performed to search for perfusion differences among lumbar vertebrae and in relation to age and sex. Upper (L1, L2) and lower (L3, L4, L5) vertebrae showed significant differences in perfusion parameters (p<0.05). Vertebrae of subjects younger than 50 years showed significantly higher perfusion compared to vertebrae of older ones (p<0.05). Vertebrae of females demonstrated significantly increased perfusion compared to those of males of corresponding age (p<0.05). All perfusion parameters, except for washout (WOUT), showed a mild linear correlation with age. Time to maximum slope (TMSP) and time to peak (TTPK) showed the same correlation with sex (0.22< r<0.32, p<0.05). Our results indicate increased perfusion of the upper compared to the lower lumbar spine, of younger compared to older subjects and of females compared to males. (orig.)

  12. Differences in perfusion parameters between upper and lower lumbar vertebral segments with dynamic contrast-enhanced MRI (DCE MRI)

    Energy Technology Data Exchange (ETDEWEB)

    Savvopoulou, Vasiliki; Vlahos, Lampros; Moulopoulos, Lia Angela [University of Athens, Areteion Hospital, Department of Radiology, Medical School, Athens (Greece); Maris, Thomas G. [University of Crete, Deparment of Medical Physics, Faculty of Medicine, Heraklion (Greece)

    2008-09-15

    To investigate the influence of age, sex and spinal level on perfusion parameters of normal lumbar bone marrow with dynamic contrast-enhanced MRI (DCE MRI). Sixty-seven subjects referred for evaluation of low back pain or sciatica underwent DCE MRI of the lumbar spine. After subtraction of dynamic images, a region of interest (ROI) was placed on each lumbar vertebral body of all subjects, and time intensity curves were generated. Consequently, perfusion parameters were calculated. Statistical analysis was performed to search for perfusion differences among lumbar vertebrae and in relation to age and sex. Upper (L1, L2) and lower (L3, L4, L5) vertebrae showed significant differences in perfusion parameters (p<0.05). Vertebrae of subjects younger than 50 years showed significantly higher perfusion compared to vertebrae of older ones (p<0.05). Vertebrae of females demonstrated significantly increased perfusion compared to those of males of corresponding age (p<0.05). All perfusion parameters, except for washout (WOUT), showed a mild linear correlation with age. Time to maximum slope (TMSP) and time to peak (TTPK) showed the same correlation with sex (0.22perfusion of the upper compared to the lower lumbar spine, of younger compared to older subjects and of females compared to males. (orig.)

  13. Contrast-enhanced 3D MRI of lung perfusion in children with cystic fibrosis - initial results

    International Nuclear Information System (INIS)

    Eichinger, Monika; Puderbach, Michael; Zuna, Ivan; Kauczor, Hans-Ulrich; Fink, Christian; Gahr, Julie; Mueller, Frank-Michael; Ley, Sebastian; Plathow, Christian; Tuengerthal, Siegfried

    2006-01-01

    This paper is a feasibility study of magnetic resonance imaging (MRI) of lung perfusion in children with cystic fibrosis (CF) using contrast-enhanced 3D MRI. Correlation assessment of perfusion changes with structural abnormalities. Eleven CF patients (9 f, 2 m; median age 16 years) were examined at 1.5 T. Morphology: HASTE coronal, transversal (TR/TE/α/ST: 600 ms/28 ms/180 /6 mm), breath-hold 18 s. Perfusion: Time-resolved 3D GRE pulse sequence (FLASH, TE/TR/α: 0.8/1.9 ms/40 ), parallel imaging (GRAPPA, PAT 2). Twenty-five data sets were acquired after intravenous injection of 0.1 mmol/kg body weight of gadodiamide, 3-5 ml/s. A total of 198 lung segments were analyzed by two radiologists in consensus and scored for morphological and perfusion changes. Statistical analysis was performed by Mantel-Haenszel chi-square test. Results showed that perfusion defects were observed in all patients and present in 80% of upper, and 39% of lower lobes. Normal lung parenchyma showed homogeneous perfusion (86%, P<0.0001). Severe morphological changes led to perfusion defects (97%, P<0.0001). Segments with moderate morphological changes showed normal (53%) or impaired perfusion (47%). In conclusion, pulmonary perfusion is easy to judge in segments with normal parenchyma or severe changes. In moderately damaged segments, MRI of lung perfusion may help to better assess actual functional impairment. Contrast-enhanced 3D MRI of lung perfusion has the potential for early vascular functional assessment and therapy control in CF patients. (orig.)

  14. Arterial spin-labelling perfusion MRI and outcome in neonates with hypoxic-ischemic encephalopathy

    Energy Technology Data Exchange (ETDEWEB)

    Vis, Jill B. de; Hendrikse, Jeroen [University Medical Center Utrecht, Department of Radiology, HP E 01.132, P.O. Box 85500, Utrecht (Netherlands); Petersen, Esben T. [University Medical Center Utrecht, Department of Radiology, HP E 01.132, P.O. Box 85500, Utrecht (Netherlands); University Medical Center Utrecht, Department of Radiotherapy, Utrecht (Netherlands); Vries, Linda S. de; Bel, Frank van; Alderliesten, Thomas; Negro, Simona; Groenendaal, Floris; Benders, Manon J.N.L. [Wilhelmina Children' s Hospital/University Medical Center Utrecht, Department of Neonatology, Utrecht (Netherlands)

    2015-01-15

    Hyperperfusion may be related to outcome in neonates with hypoxic-ischemic encephalopathy (HIE). The purpose of this study was to evaluate whether arterial spin labelling (ASL) perfusion is associated with outcome in neonates with HIE and to compare the predictive value of ASL MRI to known MRI predictive markers. Twenty-eight neonates diagnosed with HIE and assessed with MR imaging (conventional MRI, diffusion-weighted MRI, MR spectroscopy [MRS], and ASL MRI) were included. Perfusion in the basal ganglia and thalami was measured. Outcome at 9 or 18 months of age was scored as either adverse (death or cerebral palsy) or favourable. The median (range) perfusion in the basal ganglia and thalami (BGT) was 63 (28-108) ml/100 g/min in the neonates with adverse outcome and 28 (12-51) ml/100 g/min in the infants with favourable outcome (p < 0.01). The area-under-the-curve was 0.92 for ASL MRI, 0.97 for MRI score, 0.96 for Lac/NAA and 0.92 for ADC in the BGT. The combination of Lac/NAA and ASL MRI results was the best predictor of outcome (r {sup 2} = 0.86, p < 0.001). Higher ASL perfusion values in neonates with HIE are associated with a worse neurodevelopmental outcome. A combination of the MRS and ASL MRI information is the best predictor of outcome. (orig.)

  15. Grading of cerebral gilomas: correlation with perfusion MRI, spectroscopic MRI and histopathology

    International Nuclear Information System (INIS)

    Law, M.; Cha, S.; Knopp, E.A.; Johnson, G.; Litt, A.W.

    2002-01-01

    Full text: The aim of this study was to determine the correlation between perfusion MRI (pMRI), spectroscopic MRI (sMRI) and histopathologic grading of primary glial neoplasms. Echo-planar pMRI has already been shown to be a robust physiological tool in preoperatively predicting tumor grade and guiding stereotactic biopsy (1). Thirty-four patients with a primary glial neoplasm underwent conventional MR imaging, T2*-weighted echo planar pMRI and sMRI. Four rCBV measurements were obtained from the colour maps of each lesion to determine the maximum rCBV. Spectroscopic MRI utilizing 2D chemical shift imaging at a TE of 135 provided multi-voxel spectroscopic data in sixteen of these patients. The maximum Cho/NAA, Cho/Cr, and minimum NAA/Cr ratios were obtained as well as documenting the presence of lactate and lipids. This was compared with the histopathological grading (including staining with H and E, GFAP, vimentin and MIB1, proliferative index) obtained from volumetric resection or stereotactic biopsy. The maximum rCBV in high grade tumors (n=26) ranged from 1.34 to 5.15, with a mean of 3.00 ± 1.21 (SD), and in the low grade tumors (n=8) ranged from 1.47 to 2.49, with a mean of 1.81 ± 1.21 (SD).This difference was statistically significant (p<0.001; Student t test). Maximum values for Cho/NAA, Cho/Cr and minimum NAA/Cr values were 3.24 ± 3.26, 2.49 ± 1.17 and 1.02 ± 0.34, respectively in the high grade (n = 11), and 1.3 ± 0.39, 1.58 ± 0.45 and 0.89 ± 0.37 respectively in the low-grade tumors (n = 5). A statistically significant difference was found for the Cho/Cr ratio (p<0.05) between the high grade and low grade groups. Relative CBV measurements and spectroscopic metabolic ratios are complementary and correlate with histopathology (2,3). These tools provide powerful physiological and metabolic information for preoperative prediction of tumor grade and will guide pre and post operative planning and management. Copyright (2002) Blackwell Science Pty Ltd

  16. Arterial spin-labelling perfusion MRI and outcome in neonates with hypoxic-ischemic encephalopathy

    International Nuclear Information System (INIS)

    Vis, Jill B. de; Hendrikse, Jeroen; Petersen, Esben T.; Vries, Linda S. de; Bel, Frank van; Alderliesten, Thomas; Negro, Simona; Groenendaal, Floris; Benders, Manon J.N.L.

    2015-01-01

    Hyperperfusion may be related to outcome in neonates with hypoxic-ischemic encephalopathy (HIE). The purpose of this study was to evaluate whether arterial spin labelling (ASL) perfusion is associated with outcome in neonates with HIE and to compare the predictive value of ASL MRI to known MRI predictive markers. Twenty-eight neonates diagnosed with HIE and assessed with MR imaging (conventional MRI, diffusion-weighted MRI, MR spectroscopy [MRS], and ASL MRI) were included. Perfusion in the basal ganglia and thalami was measured. Outcome at 9 or 18 months of age was scored as either adverse (death or cerebral palsy) or favourable. The median (range) perfusion in the basal ganglia and thalami (BGT) was 63 (28-108) ml/100 g/min in the neonates with adverse outcome and 28 (12-51) ml/100 g/min in the infants with favourable outcome (p 2 = 0.86, p < 0.001). Higher ASL perfusion values in neonates with HIE are associated with a worse neurodevelopmental outcome. A combination of the MRS and ASL MRI information is the best predictor of outcome. (orig.)

  17. Myocardial perfusion scintigraphy with exercise and pharmacological stress

    International Nuclear Information System (INIS)

    Sundram, F.X.

    1995-01-01

    Cardiac studies including myocardial perfusion scintigraphy was begun in the Singapore General Hospital, nuclear medicine department in 1983. From a few patients per year using planar imaging, we have in 1994 studied 1500 patients for myocardial perfusion, using mainly SPECT (single-photon emission computerised tomography) and radionuclides such as Thallium-201, Technetium-99m sestamibi and Tc-99m tetrofosmin. Patients have been stressed using treadmill exercise or pharmacological agents; we have used dipyridamole, and dobutamine for pharmacological stress but have no experience with intravenous adenosine

  18. Myocardial perfusion scintigraphy with exercise and pharmacological stress

    Energy Technology Data Exchange (ETDEWEB)

    Sundram, F X [General Hospital of Singapore, Dept. of Nuclear Medicine (Senegal)

    1996-12-31

    Cardiac studies including myocardial perfusion scintigraphy was begun in the Singapore General Hospital, nuclear medicine department in 1983. From a few patients per year using planar imaging, we have in 1994 studied 1500 patients for myocardial perfusion, using mainly SPECT (single-photon emission computerised tomography) and radionuclides such as Thallium-201, Technetium-99m sestamibi and Tc-99m tetrofosmin. Patients have been stressed using treadmill exercise or pharmacological agents; we have used dipyridamole, and dobutamine for pharmacological stress but have no experience with intravenous adenosine.

  19. Perfusion MRI as a neurosurgical tool for improved targeting in stereotactic tumor biopsies.

    Science.gov (United States)

    Lefranc, M; Monet, P; Desenclos, C; Peltier, J; Fichten, A; Toussaint, P; Sevestre, H; Deramond, H; Le Gars, D

    2012-01-01

    Stereotactic biopsies are subject to sampling errors (essentially due to target selection). The presence of contrast enhancement is not a reliable marker of malignancy. The goal of the present study was to determine whether perfusion-weighted imaging can improve target selection in stereotactic biopsies. We studied 21 consecutive stereotactic biopsies between June 2009 and March 2010. Perfusion-weighted magnetic resonance imaging (MRI) was integrated into our neuronavigator. Perfusion-weighted imaging was used as an adjunct to conventional MRI data for target determination. Conventional MRI alone was used to determine the trajectory. We found a linear correlation between regional cerebral blood volume (rCBV) and vessel density (number of vessels per mm(2); R = 0.64; p < 0.001). Perfusion-weighted imaging facilitated target determination in 11 cases (52.4%), all of which were histopathologically diagnosed as glial tumors. For glial tumors, which presented with contrast enhancement, perfusion-weighted imaging identified a more precisely delimited target in 9 cases, a different target in 1 case, and exactly the same target in 1 other case. In all cases, perfusion-selected sampling provided information on cellular features and tumor grading. rCBV was significantly associated with grading (p < 0.01), endothelial proliferation (p < 0.01), and vessel density (p < 0.01). For lesions with rCBV values ≤1, perfusion-weighted MRI did not help to determine the target but was useful for surgical management. For stereotactic biopsies, targeting based on perfusion-weighted imaging is a feasible method for reducing the sampling error and improving target selection in the histopathological diagnosis of tumors with high rCBVs. Copyright © 2012 S. Karger AG, Basel.

  20. Quantitative analysis of pulmonary perfusion using time-resolved parallel 3D MRI - initial results

    International Nuclear Information System (INIS)

    Fink, C.; Buhmann, R.; Plathow, C.; Puderbach, M.; Kauczor, H.U.; Risse, F.; Ley, S.; Meyer, F.J.

    2004-01-01

    Purpose: to assess the use of time-resolved parallel 3D MRI for a quantitative analysis of pulmonary perfusion in patients with cardiopulmonary disease. Materials and methods: eight patients with pulmonary embolism or pulmonary hypertension were examined with a time-resolved 3D gradient echo pulse sequence with parallel imaging techniques (FLASH 3D, TE/TR: 0.8/1.9 ms; flip angle: 40 ; GRAPPA). A quantitative perfusion analysis based on indicator dilution theory was performed using a dedicated software. Results: patients with pulmonary embolism or chronic thromboembolic pulmonary hypertension revealed characteristic wedge-shaped perfusion defects at perfusion MRI. They were characterized by a decreased pulmonary blood flow (PBF) and pulmonary blood volume (PBV) and increased mean transit time (MTT). Patients with primary pulmonary hypertension or eisenmenger syndrome showed a more homogeneous perfusion pattern. The mean MTT of all patients was 3.3 - 4.7 s. The mean PBF and PBV showed a broader interindividual variation (PBF: 104-322 ml/100 ml/min; PBV: 8 - 21 ml/100 ml). Conclusion: time-resolved parallel 3D MRI allows at least a semi-quantitative assessment of lung perfusion. Future studies will have to assess the clinical value of this quantitative information for the diagnosis and management of cardiopulmonary disease. (orig.) [de

  1. Arterial spin labelling perfusion MRI of breast cancer using FAIR TrueFISP: Initial results

    International Nuclear Information System (INIS)

    Buchbender, S.; Obenauer, S.; Mohrmann, S.; Martirosian, P.; Buchbender, C.; Miese, F.R.; Wittsack, H.J.; Miekley, M.; Antoch, G.; Lanzman, R.S.

    2013-01-01

    Aim: To assess the feasibility of an unenhanced, flow-sensitive, alternating inversion recovery-balanced steady-state free precession (FAIR TrueFISP) arterial spin labelling (ASL) magnetic resonance imaging (MRI) technique for quantification of breast cancer perfusion. Materials and methods: Eighteen untreated breast tumour patients (mean age 53 ± 17 years, range 30–68 years) and four healthy controls (mean age 51 ± 14 years, range 33–68 years) were enrolled in this study and were imaged using a clinical 1.5 T MRI machine. Perfusion measurements were performed using a coronal single-section ASL FAIR TrueFISP technique in addition to a routine breast MRI examination. T1 relaxation time of normal breast parenchyma was determined in four healthy volunteers using the variable flip angle approach. The definitive diagnosis was obtained at histology after biopsy or surgery and was available for all patients. Results: ASL perfusion was successfully acquired in 13 of 18 tumour patients and in all healthy controls. The mean ASL perfusion of invasive ductal carcinoma tissue was significantly higher (88.2 ± 39.5 ml/100 g/min) compared to ASL perfusion of normal breast parenchyma (24.9 ± 12.7 ml/100 g/min; p < 0.05) and invasive lobular carcinoma (30.5 ± 4.3 ml/100 g/min; p < 0.05). No significant difference was found between the mean ASL perfusion of normal breast parenchyma and invasive lobular carcinoma tissue (p = 0.97). Conclusion: ASL MRI enables quantification of breast cancer perfusion without the use of contrast material. However, its impact on diagnosis and therapy management of breast tumours has to be evaluated in larger patient studies

  2. Clinical evaluation of non-invasive perfusion-weighted MRI

    International Nuclear Information System (INIS)

    Takasu, Miyuki

    2000-01-01

    A spin labeling method to measure cerebral blood flow without a contrast medium was developed and applied clinically to obtain a non-invasive perfusion-weighted image. The purpose of this study is to compare the non-invasive perfusion-weighted image using FAIR with the well-established PWI using a bolus injection of Gd-DTPA. Of 41 lesions which revealed decreased perfusion, 13 were shown to be low signal intensity areas on FAIR. Therefore, detection rate of FAIR for hypoperfusion was 32%. Of 8 lesions which revealed increased perfusion, 7 demonstrated high intensity on FAIR. Therefore, detection rate of FAIR for hyperperfusion was 88%. Seven lesions were found to have a mean pixel value of zero on PWI. Of these lesions, 5 lesions could be detected as high signal intensity area on FAIR. The rCBV- and rCBF index ratios of hypoperfused lesions detected on FAIR were significantly lower than those of lesions which were not detected on FAIR (p=0.007, p=0.01). As concerns the lesions detected of FAIR, there were positive correlation between rCBV- or rCBF index ratio and FAIR signal ratio (rCBV ratio: ρ=0.873, p=0.0002, rCBF index ratio: ρ=0.858, p=0.0003). FAIR is valuable clinical tool to detect perfusion abnormality semi-quantitatively without contrast medium, although it showed relatively low detection rate for hypoperfused lesions. (author)

  3. Safety of adenosine in stress cerebral perfusion imaging

    International Nuclear Information System (INIS)

    Hu Pengcheng; Gu Yushen; Liu Wenguan; Xiu Yan; Zhu Weimin; Chen Shuguang; Shi Hongcheng

    2009-01-01

    Objective: To evaluate the safety of adenosine as pharmacological stress agents in stress cerebral perfusion imaging. Methods: Eighty patients under investigation for suspected cerebral vessel disease were recruited. Each had a resting scan and a stress scan on different days. The adenosine stress protocol was as same as the protocol used in adenosine stress myocardial perfusion imaging. Subjective and objective side-effects were investigated during pharmacological stress procedure. Results: All patients completed the 6 min infusion protocol without premature termination on safety criteria or due to intolerable symptoms. 46 patients had mild side effects. 20 patients (25%) had dizziness, 12 patients (15%) had palpitation, 1 patient (1%) was hypotensive, 7 patients (9%) had dyspnoea, 4 patients (5%) felt hot, 3 patients (4%) had sweat, 4 patients (5%) had nausea, 6 patients (8%) had flushing, 19 patients (24%) had chest pain, 6 patients (8%) had abdomen pain, 3 patients (4%) had abnormal taste and 1 patient (1%) were thirsty. Transient ST change occurred in only 1 patient. Conclusion: Adenosine stress cerebral perfusion imaging is a safe diagnostic method with mild side effects. (authors)

  4. Neuroradiological findings in primary progressive aphasia: CT, MRI and cerebral perfusion SPECT

    International Nuclear Information System (INIS)

    Sinnatamby, R.; Antoun, N.A.; Freer, C.E.L.; Miles, K.A.; Hodges, J.R.

    1996-01-01

    Primary progressive aphasia (PPA) is defined as progressive decline in language for 2 or more years with preservation of activities of daily living and general cognitive functions. Whereas the clinical features of this syndrome have been well documented, the neuroradiological findings have not been studied systematically. We studied 13 patients with PPA retrospectively: 10 underwent CT, 12 MRI and 12 cerebral perfusion studies using 99m Tc-HMPAO SPECT. CT and MR images were scored for focal atrophy by two independent assessors. Initial qualitative assessment of SPECT images was confirmed by quantitative analysis. CY was normal in 5 patients. Focal atrophy, affecting predominantly the left temporal lobe, was seen in 4 of 10 patients on CT, and 10 of 12 on MRI. Atrophy was localised primarily to the superior and middle temporal gyri on MRI. All 12 patients who underwent SPECT had unilateral temporal lobe perfusion defects, in 2 patients of whom MRI was normal. CT is relatively insensitive to focal abnormalities in PPA; MRI and SPECT are the imaging modalities of choice. MRI allows accurate, specific localisation of atrophy with the temporal neocortex. SPECT may reveal a functional decrease in cerebral perfusion prior to establishment of structural change. (orig.)

  5. Neuroradiological findings in primary progressive aphasia: CT, MRI and cerebral perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Sinnatamby, R. [Dept. of Radiology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Antoun, N.A. [Dept. of Radiology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Freer, C.E.L. [Dept. of Radiology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Miles, K.A. [Dept. of Nuclear Medicine, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Hodges, J.R. [Dept. of Neurology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom)

    1996-04-01

    Primary progressive aphasia (PPA) is defined as progressive decline in language for 2 or more years with preservation of activities of daily living and general cognitive functions. Whereas the clinical features of this syndrome have been well documented, the neuroradiological findings have not been studied systematically. We studied 13 patients with PPA retrospectively: 10 underwent CT, 12 MRI and 12 cerebral perfusion studies using {sup 99m}Tc-HMPAO SPECT. CT and MR images were scored for focal atrophy by two independent assessors. Initial qualitative assessment of SPECT images was confirmed by quantitative analysis. CY was normal in 5 patients. Focal atrophy, affecting predominantly the left temporal lobe, was seen in 4 of 10 patients on CT, and 10 of 12 on MRI. Atrophy was localised primarily to the superior and middle temporal gyri on MRI. All 12 patients who underwent SPECT had unilateral temporal lobe perfusion defects, in 2 patients of whom MRI was normal. CT is relatively insensitive to focal abnormalities in PPA; MRI and SPECT are the imaging modalities of choice. MRI allows accurate, specific localisation of atrophy with the temporal neocortex. SPECT may reveal a functional decrease in cerebral perfusion prior to establishment of structural change. (orig.)

  6. Stress Perfusion Coronary Flow Reserve Versus Cardiac Magnetic Resonance for Known or Suspected CAD.

    Science.gov (United States)

    Kato, Shingo; Saito, Naka; Nakachi, Tatsuya; Fukui, Kazuki; Iwasawa, Tae; Taguri, Masataka; Kosuge, Masami; Kimura, Kazuo

    2017-08-15

    Phase-contrast (PC) cine magnetic resonance imaging (MRI) of the coronary sinus is a noninvasive method to quantify coronary flow reserve (CFR). This study sought to compare the prognostic value of CFR by cardiac magnetic resonance (CMR) and stress perfusion CMR to predict major adverse cardiac events (MACE). Participants included 276 patients with known coronary artery disease (CAD) and 400 with suspected CAD. CFR was calculated as myocardial blood flow during adenosine triphosphate infusion divided by myocardial blood flow at rest using PC cine MRI of the coronary sinus. During a median follow-up of 2.3 years, 47 patients (7%) experienced MACE. Impaired CFR (10% ischemia on stress perfusion CMR were significantly associated with MACE in patients with known CAD (hazard ratio [HR]: 5.17 and HR: 5.10, respectively) and suspected CAD (HR: 14.16 and HR: 6.50, respectively). The area under the curve for predicting MACE was 0.773 for CFR and 0.731 for stress perfusion CMR (p = 0.58) for patients with known CAD, and 0.885 for CFR and 0.776 for stress perfusion CMR (p = 0.059) in the group with suspected CAD. In patients with known CAD, sensitivity, specificity, and positive and negative predictive values to predict MACE were 64%, 91%, 38%, and 97%, respectively, for CFR, and 82%, 59%, 15%, and 97%, respectively, for stress perfusion CMR. In the suspected CAD group, these values were 65%, 99%, 80%, and 97%, respectively, for CFR, and 72%, 83%, 22%, and 98%, respectively, for stress perfusion CMR. The predictive values of CFR and stress perfusion CMR for MACE were comparable in patients with known CAD. In patients with suspected CAD, CFR showed higher HRs and areas under the curve than stress perfusion CMR, suggesting that CFR assessment by PC cine MRI might provide better risk stratification for patients with suspected CAD. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Cerebral perfusion alterations in epileptic patients during peri-ictal and post-ictal phase: PASL vs DSC-MRI.

    Science.gov (United States)

    Pizzini, Francesca B; Farace, Paolo; Manganotti, Paolo; Zoccatelli, Giada; Bongiovanni, Luigi G; Golay, Xavier; Beltramello, Alberto; Osculati, Antonio; Bertini, Giuseppe; Fabene, Paolo F

    2013-07-01

    Non-invasive pulsed arterial spin labeling (PASL) MRI is a method to study brain perfusion that does not require the administration of a contrast agent, which makes it a valuable diagnostic tool as it reduces cost and side effects. The purpose of the present study was to establish the viability of PASL as an alternative to dynamic susceptibility contrast (DSC-MRI) and other perfusion imaging methods in characterizing changes in perfusion patterns caused by seizures in epileptic patients. We evaluated 19 patients with PASL. Of these, the 9 affected by high-frequency seizures were observed during the peri-ictal period (within 5hours since the last seizure), while the 10 patients affected by low-frequency seizures were observed in the post-ictal period. For comparison, 17/19 patients were also evaluated with DSC-MRI and CBF/CBV. PASL imaging showed focal vascular changes, which allowed the classification of patients in three categories: 8 patients characterized by increased perfusion, 4 patients with normal perfusion and 7 patients with decreased perfusion. PASL perfusion imaging findings were comparable to those obtained by DSC-MRI. Since PASL is a) sensitive to vascular alterations induced by epileptic seizures, b) comparable to DSC-MRI for detecting perfusion asymmetries, c) potentially capable of detecting time-related perfusion changes, it can be recommended for repeated evaluations, to identify the epileptic focus, and in follow-up and/or therapy-response assessment. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. A brain stress test: Cerebral perfusion during memory encoding in mild cognitive impairment.

    Science.gov (United States)

    Xie, Long; Dolui, Sudipto; Das, Sandhitsu R; Stockbower, Grace E; Daffner, Molly; Rao, Hengyi; Yushkevich, Paul A; Detre, John A; Wolk, David A

    2016-01-01

    Arterial spin labeled perfusion magnetic resonance imaging (ASL MRI) provides non-invasive quantification of cerebral blood flow, which can be used as a biomarker of brain function due to the tight coupling between cerebral blood flow (CBF) and brain metabolism. A growing body of literature suggests that regional CBF is altered in neurodegenerative diseases. Here we examined ASL MRI CBF in subjects with amnestic mild cognitive impairment (n = 65) and cognitively normal healthy controls (n = 62), both at rest and during performance of a memory-encoding task. As compared to rest, task-enhanced ASL MRI improved group discrimination, which supports the notion that physiologic measures during a cognitive challenge, or "stress test", may increase the ability to detect subtle functional changes in early disease stages. Further, logistic regression analysis demonstrated that ASL MRI and concomitantly acquired structural MRI provide complementary information of disease status. The current findings support the potential utility of task-enhanced ASL MRI as a biomarker in early Alzheimer's disease.

  9. Arterial spin labelling MRI for assessment of cerebral perfusion in children with moyamoya disease: comparison with dynamic susceptibility contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Goetti, Robert [University Children' s Hospital Zurich, Department of Diagnostic Imaging, Zurich (Switzerland); University Hospital Zurich, Department of Diagnostic and Interventional Radiology, Zurich (Switzerland); O' Gorman, Ruth [University Children' s Hospital Zurich, Center for MR Research, Zurich (Switzerland); Khan, Nadia [University Children' s Hospital Zurich, Moyamoya Center, Division of Neurosurgery, Department of Surgery, Zurich (Switzerland); Kellenberger, Christian J.; Scheer, Ianina [University Children' s Hospital Zurich, Department of Diagnostic Imaging, Zurich (Switzerland)

    2013-05-15

    This study seeks to evaluate the diagnostic accuracy of cerebral perfusion imaging with arterial spin labelling (ASL) MR imaging in children with moyamoya disease compared to dynamic susceptibility contrast (DSC) imaging. Ten children (7 females; age, 9.2 {+-} 5.4 years) with moyamoya disease underwent cerebral perfusion imaging with ASL and DSC on a 3-T MRI scanner in the same session. Cerebral perfusion images were acquired with ASL (pulsed continuous 3D ASL sequence, 32 axial slices, TR = 5.5 s, TE = 25 ms, FOV = 24 cm, matrix = 128 x 128) and DSC (gradient echo EPI sequence, 35 volumes of 28 axial slices, TR = 2,000 ms, TE = 36 ms, FOV = 24 cm, matrix = 96 x 96, 0.2 ml/kg Gd-DOTA). Cerebral blood flow maps were generated. ASL and DSC images were qualitatively assessed regarding perfusion of left and right ACA, MCA, and PCA territories by two independent readers using a 3-point-Likert scale and quantitative relative cerebral blood flow (rCBF) was calculated. Correlation between ASL and DSC for qualitative and quantitative assessment and the accuracy of ASL for the detection of reduced perfusion per territory with DSC serving as the standard of reference were calculated. With a good interreader agreement ({kappa} = 0.62) qualitative perfusion assessment with ASL and DSC showed a strong and significant correlation ({rho} = 0.77; p < 0.001), as did quantitative rCBF (r = 0.79; p < 0.001). ASL showed a sensitivity, specificity and accuracy of 94 %, 93 %, and 93 % for the detection of reduced perfusion per territory. In children with moyamoya disease, unenhanced ASL enables the detection of reduced perfusion per vascular territory with a good accuracy compared to contrast-enhanced DSC. (orig.)

  10. Diffusion and perfusion MRI for the localisation of epileptogenic foci in drug-resistant epilepsy

    International Nuclear Information System (INIS)

    Heiniger, P.; El-Koussy, M.; Kiefer, C.; Oswald, H.; Schroth, G.; Schindler, K.; Donati, F.; Loevblad, K.O.; Wissmeyer, M.; Mariani, L.; Weder, B.

    2002-01-01

    Drug-resistant epilepsy is an important clinical challenge, both diagnostically and therapeutically. More and more surgical options are being considered, but precise presurgical assessment is necessary. We prospectively studied eight patients with drug-resistant epilepsy, who underwent clinical examination, single photon emission computed tomography (SPECT) and interictal MRI, including diffusion- and perfusion-weighted echoplanar sequences. Lesions suspected on SPECT of being epileptogenic showed mild hypoperfusion, while the diffusion-weighted MRI (DWI) revealed increased apparent diffusion coefficients relative to the other side. However, these abnormalities were not visible on the corresponding maps. We showed that DWI and perfusion-weighted MRI could be used confirm the characteristics and site of an epileptogenic area in patients with drug-resistant epilepsy. (orig.)

  11. Investigation of contrast agent dosage for perfusion-weighted MRI

    International Nuclear Information System (INIS)

    Erb, G.; Benner, T.; Heiland, S.; Reith, W.; Sartor, K.; Forsting, M.

    1997-01-01

    Purpose: In this study we investigated, whether increasing the dosage of a paramagnetic contrast agent results in a stronger signal decrease in T 2 *-weighted perfusion sequences and therefore more meaningful parameter maps. Material and methods: In a prospective study bolus injection of gadolinium-DTPA was performed at dosages of 0.1, 0.2, and 0.3 mmol/kg body weight (BW) in 10 patients each. Before, during and after bolus injection 40 T 2 *-weighted images of a reference brain slice were acquired within 65.6 seconds on a 1.0 T clinical scanner and perfusion parameters were calculated. Results: Due to the limited signal decrease during bolus passage and the resulting low signal-difference-to-noise ratio (ΔS/N) no reliable differentiation of gray and white matter was possible at a contrast agent dosage of 0.1 mmol/kg BW. Only at higher dosages, both, signal decrease and ΔS/N were strong enough to allow differentiation of gray and white matter and to yield reliable parameter maps. Conclusion: For meaningful MR perfusion imaging at 1.0 T and with the given sequence a contrast agent dosage of at least 0.2 mmol/kg BW is necessary, if a 0.5-molar contrast agent is used. (orig.) [de

  12. Assessment of brain perfusion with MRI: methodology and application to acute stroke

    International Nuclear Information System (INIS)

    Grandin, C.B.

    2003-01-01

    We review the methodology of brain perfusion measurements with MRI and their application to acute stroke, with particular emphasis on the work awarded by the 6th Lucien Appel Prize for Neuroradiology. The application of the indicator dilution theory to the dynamic susceptibility-weighted bolus-tracking method is explained, as is the approach to obtaining quantitative measurements of cerebral blood flow (CBF) and volume (CBV). Our contribution to methodological developments, such as CBV measurement with the frequency-shifted burst sequence, development of the PRESTO sequence, comparison of different deconvolution methods and of spin- and gradient-echo sequences, and the validation of MRI measurements against positron emission tomography is summarised. The pathophysiology of brain ischaemia and the role of neuroimaging in the setting of acute stroke are reviewed, with an introduction to the concepts of ischaemic penumbra and diffusion/perfusion mismatch. Our work on the determination of absolute CBF and CBV thresholds for predicting the area of infarct growth, identification of the best perfusion parameters (relative or absolute) for predicting the area of infarct growth and the role of MR angiography is also summarised. We conclude that MRI is a very powerful way to assess brain perfusion and that its use might help in selecting patients who will benefit most from treatment such as thrombolysis. (orig.)

  13. Myocardial perfusion MRI with sliding-window conjugate-gradient HYPR.

    Science.gov (United States)

    Ge, Lan; Kino, Aya; Griswold, Mark; Mistretta, Charles; Carr, James C; Li, Debiao

    2009-10-01

    First-pass perfusion MRI is a promising technique for detecting ischemic heart disease. However, the diagnostic value of the method is limited by the low spatial coverage, resolution, signal-to-noise ratio (SNR), and cardiac motion-related image artifacts. In this study we investigated the feasibility of using a method that combines sliding window and CG-HYPR methods (SW-CG-HYPR) to reduce the acquisition window for each slice while maintaining the temporal resolution of one frame per heartbeat in myocardial perfusion MRI. This method allows an increased number of slices, reduced motion artifacts, and preserves the relatively high SNR and spatial resolution of the "composite images." Results from eight volunteers demonstrate the feasibility of SW-CG-HYPR for accelerated myocardial perfusion imaging with accurate signal intensity changes of left ventricle blood pool and myocardium. Using this method the acquisition time per cardiac cycle was reduced by a factor of 4 and the number of slices was increased from 3 to 8 as compared to the conventional technique. The SNR of the myocardium at peak enhancement with SW-CG-HYPR (13.83 +/- 2.60) was significantly higher (P < 0.05) than the conventional turbo-FLASH protocol (8.40 +/- 1.62). Also, the spatial resolution of the myocardial perfection images was significantly improved. SW-CG-HYPR is a promising technique for myocardial perfusion MRI. (c) 2009 Wiley-Liss, Inc.

  14. Impaired glymphatic perfusion after strokes revealed by contrast-enhanced MRI: a new target for fibrinolysis?

    Science.gov (United States)

    Gaberel, Thomas; Gakuba, Clement; Goulay, Romain; Martinez De Lizarrondo, Sara; Hanouz, Jean-Luc; Emery, Evelyne; Touze, Emmanuel; Vivien, Denis; Gauberti, Maxime

    2014-10-01

    The aim of the present study was to investigate the impact of different stroke subtypes on the glymphatic system using MRI. We first improved and characterized an in vivo protocol to measure the perfusion of the glymphatic system using MRI after minimally invasive injection of a gadolinium chelate within the cisterna magna. Then, the integrity of the glymphatic system was evaluated in 4 stroke models in mice including subarachnoid hemorrhage (SAH), intracerebral hemorrhage, carotid ligature, and embolic ischemic stroke. We were able to reliably evaluate the glymphatic system function using MRI. Moreover, we provided evidence that the glymphatic system was severely impaired after SAH and in the acute phase of ischemic stroke, but was not altered after carotid ligature or in case of intracerebral hemorrhage. Notably, this alteration in glymphatic perfusion reduced brain clearance rate of low-molecular-weight compounds. Interestingly, glymphatic perfusion after SAH can be improved by intracerebroventricular injection of tissue-type plasminogen activator. Moreover, spontaneous arterial recanalization was associated with restoration of the glymphatic function after embolic ischemic stroke. SAH and acute ischemic stroke significantly impair the glymphatic system perfusion. In these contexts, injection of tissue-type plasminogen activator either intracerebroventricularly to clear perivascular spaces (for SAH) or intravenously to restore arterial patency (for ischemic stroke) may improve glymphatic function. © 2014 American Heart Association, Inc.

  15. Value of dynamic susceptibility contrast perfusion MRI in the acute phase of transient global amnesia.

    Directory of Open Access Journals (Sweden)

    Alex Förster

    Full Text Available Transient global amnesia (TGA is a transitory, short-lasting neurological disorder characterized by a sudden onset of antero- and retrograde amnesia. Perfusion abnormalities in TGA have been evaluated mainly by use of positron emission tomography (PET or single-photon emission computed tomography (SPECT. In the present study we explore the value of dynamic susceptibility contrast perfusion-weighted MRI (PWI in TGA in the acute phase.From a MRI report database we identified TGA patients who underwent MRI including PWI in the acute phase and compared these to control subjects. Quantitative perfusion maps (cerebral blood flow (CBF and volume (CBV were generated and analyzed by use of Signal Processing In NMR-Software (SPIN. CBF and CBV values in subcortical brain regions were assessed by use of VOI created in FIRST, a model-based segmentation tool in the Oxford Centre for Functional Magnetic Resonance Imaging of the Brain (FMRIB Software Library (FSL.Five TGA patients were included (2 men, 3 women. On PWI, no relevant perfusion alterations were found by visual inspection in TGA patients. Group comparisons for possible differences between TGA patients and control subjects showed significant lower rCBF values bilaterally in the hippocampus, in the left thalamus and globus pallidus as well as bilaterally in the putamen and the left caudate nucleus. Correspondingly, significant lower rCBV values were observed bilaterally in the hippocampus and the putamen as well as in the left caudate nucleus. Group comparisons for possible side differences in rCBF and rCBV values in TGA patients revealed a significant lower rCBV value in the left caudate nucleus.Mere visual inspection of PWI is not sufficient for the assessment of perfusion changes in TGA in the acute phase. Group comparisons with healthy control subjects might be useful to detect subtle perfusion changes on PWI in TGA patients. However, this should be confirmed in larger data sets and serial PWI

  16. Prognostic Value of Quantitative Stress Perfusion Cardiac Magnetic Resonance.

    Science.gov (United States)

    Sammut, Eva C; Villa, Adriana D M; Di Giovine, Gabriella; Dancy, Luke; Bosio, Filippo; Gibbs, Thomas; Jeyabraba, Swarna; Schwenke, Susanne; Williams, Steven E; Marber, Michael; Alfakih, Khaled; Ismail, Tevfik F; Razavi, Reza; Chiribiri, Amedeo

    2018-05-01

    This study sought to evaluate the prognostic usefulness of visual and quantitative perfusion cardiac magnetic resonance (CMR) ischemic burden in an unselected group of patients and to assess the validity of consensus-based ischemic burden thresholds extrapolated from nuclear studies. There are limited data on the prognostic value of assessing myocardial ischemic burden by CMR, and there are none using quantitative perfusion analysis. Patients with suspected coronary artery disease referred for adenosine-stress perfusion CMR were included (n = 395; 70% male; age 58 ± 13 years). The primary endpoint was a composite of cardiovascular death, nonfatal myocardial infarction, aborted sudden death, and revascularization after 90 days. Perfusion scans were assessed visually and with quantitative analysis. Cross-validated Cox regression analysis and net reclassification improvement were used to assess the incremental prognostic value of visual or quantitative perfusion analysis over a baseline clinical model, initially as continuous covariates, then using accepted thresholds of ≥2 segments or ≥10% myocardium. After a median 460 days (interquartile range: 190 to 869 days) follow-up, 52 patients reached the primary endpoint. At 2 years, the addition of ischemic burden was found to increase prognostic value over a baseline model of age, sex, and late gadolinium enhancement (baseline model area under the curve [AUC]: 0.75; visual AUC: 0.84; quantitative AUC: 0.85). Dichotomized quantitative ischemic burden performed better than visual assessment (net reclassification improvement 0.043 vs. 0.003 against baseline model). This study was the first to address the prognostic benefit of quantitative analysis of perfusion CMR and to support the use of consensus-based ischemic burden thresholds by perfusion CMR for prognostic evaluation of patients with suspected coronary artery disease. Quantitative analysis provided incremental prognostic value to visual assessment and

  17. Perfusion MRI for the prediction of treatment response after preoperative chemoradiotherapy in locally advanced rectal cancer

    International Nuclear Information System (INIS)

    Lim, Joon Seok; Baek, Song-Ee; Kim, Myeong-Jin; Suh, Jinsuk; Kim, Ki Whang; Kim, Daehong; Myoung, Sungmin; Choi, Junjeong; Shin, Sang Joon; Kim, Nam Kyu; Keum, Ki Chang

    2012-01-01

    To evaluate the utility of perfusion MRI as a potential biomarker for predicting response to chemoradiotherapy (CRT) in locally advanced rectal cancer. Thirty-nine patients with primary rectal carcinoma who were scheduled for preoperative CRT were prospectively recruited. Perfusion MRI was performed with a 3.0-T MRI system in all patients before therapy, at the end of the 2nd week of therapy, and before surgery. The K trans (volume transfer constant) and V e (extracellular extravascular space fraction) were calculated. Before CRT, the mean tumour K trans in the downstaged group was significantly higher than that in the non-downstaged group (P = 0.0178), but there was no significant difference between tumour regression grade (TRG) responders and TRG non-responders (P = 0.1392). Repeated-measures analysis of variance (ANOVA) showed significant differences for evolution of K trans values both between downstaged and non-downstaged groups (P = 0.0215) and between TRG responders and TRG non-responders (P = 0.0001). Regarding V e , no significant differences were observed both between downstaged and non-downstaged groups (P = 0.689) or between TRG responders and TRG non-responders (P = 0.887). Perfusion MRI of rectal cancer can be useful for assessing tumoural K trans changes by CRT. Tumours with high pre-CRT K trans values tended to respond favourably to CRT, particularly in terms of downstaging criteria. (orig.)

  18. Stress-only myocardial perfusion scintigraphy

    DEFF Research Database (Denmark)

    Ejlersen, June A; May, Ole; Mortensen, Jesper

    2017-01-01

    and novice): familiar and unfamiliar with AC. The two experts also made a consensus reading of the integrated stress-rest datasets. The consensus reading and quantitative data from the invasive coronary angiography were applied as reference methods. RESULTS: The sensitivity/specificity were 0.......92-1.00/0.73-0.90 (reference: expert consensus reading), 0.93-0.96/0.63-0.82 (reference: ≥1 stenosis>70%), and 0.75-0.88/0.70-0.88 (reference: ≥1 stenosis>50%). The four readers showed a high and fairly equal sensitivity independent of their familiarity with AC. The expert familiar with AC had the highest specificity...

  19. Renal Cell Carcinoma Perfusion before and after Radiofrequency Ablation Measured with Dynamic Contrast Enhanced MRI: A Pilot Study.

    Science.gov (United States)

    Wah, Tze Min; Sourbron, Steven; Wilson, Daniel Jonathan; Magee, Derek; Gregory, Walter Martin; Selby, Peter John; Buckley, David L

    2018-01-08

    To investigate if the early treatment effects of radiofrequency ablation (RFA) on renal cell carcinoma (RCC) can be detected with dynamic contrast enhanced (DCE)-MRI and to correlate RCC perfusion with RFA treatment time. 20 patients undergoing RFA of their 21 RCCs were evaluated with DCE-MRI before and at one month after RFA treatment. Perfusion was estimated using the maximum slope technique at two independent sittings. Total RCC blood flow was correlated with total RFA treatment time, tumour location, size and histology. DCE-MRI examinations were successfully evaluated for 21 RCCs (size from 1.3 to 4 cm). Perfusion of the RCCs decreased significantly ( p measuring RCC perfusion before and after RFA. Perfusion significantly decreases in the zone of ablation, suggesting that it may be useful for the assessment of treatment efficacy. Pre-RFA RCC blood flow may be used to predict RFA treatment time.

  20. MRI and MRA of kidney transplants - evaluation of vessels and perfusion

    International Nuclear Information System (INIS)

    Wiesner, W.; Pfammatter, T.; Krestin, G.P.; Debatin, J.F.

    1998-01-01

    Purpose: To document the value of fast contrast enhanced-sequences in the assessment of the vascular supply and parenchymal perfusion in renal transplants. Patients: 18 recipients of a renal transplant were examined with a 1.5-Tesla-MR-system. The protocol included fast contrast enhanced 3D MR angiography and coronal 2D GRE sequences. The transplant artery and vein were assessed as well as regional parenchymal perfusion. Results: 3D MRA detected three transplant artery stenoses and one occlusion. In addition, two renal vein thromboses and one compression were identified. Perfusion deficits were documented in 8 renal transplants: Renal infarction (n=4), cortical necrosis (n=2), acute tubular necrosis (n=1) and venous ischemia (n=1). Fluid collections were documented as well as dilatation of the collecting system and abnormalities of the surrounding tissues. Conclusion: Contrast enhanced MRI and MRA permit a comprehensive assessment of renal transplants without inducing nephrotoxicity. (orig.) [de

  1. Simultaneous maximal exercise radionuclide angiography and thallium stress perfusion imaging

    International Nuclear Information System (INIS)

    Narahara, K.A.; Mena, I.; Maublant, J.C.; Brizendine, M.; Criley, J.M.

    1984-01-01

    Gold-195m is a new ultra-short-lived radionuclide that can be used for cardiac studies. Accurate, reproducible ejection fraction and ventricular wall motion studies can be obtained from first-transit angiography using commercially available imaging and image-processing equipment. The short half-life of gold-195m (30.5 seconds) makes simultaneous dual isotope imaging possible and substantially reduces the radiation exposure from the isotope angiography. The feasibility and possible benefits of performing dual radionuclide studies were evaluated during a single exercise stress test in 24 subjects with known coronary artery disease (CAD) and in 20 normal volunteers. High-quality first-transit angiograms were obtained in all subjects. An 83% sensitivity and 95% specificity for detecting CAD with thallium-201 imaging was noted in this investigation, suggesting that its diagnostic accuracy was not altered by simultaneous dual isotone imaging. When segmental left ventricular (LV) wall motion was compared with thallium-201 perfusion imaging, divergent results were noted in 15 of 44 subjects. An analysis of the ejection fraction (EF) results at rest and stress provided additional information that could be useful in assessing the clinical significance of such differences in segmental wall motion and perfusion. Simultaneous dual isotope imaging appears to be appropriate for situations in which both LV perfusion and function require evaluation. The use of gold-195m allows such information to be obtained from a single exercise test and can thereby reduce the cost and time required for noninvasive evaluations of patients for CAD

  2. Diffusion- and perfusion-weighted MRI in a patient with a prolonged reversible ischaemic neurological deficit

    International Nuclear Information System (INIS)

    Neumann-Haefelin, T.; Wittsack, H.J.; Wenserski, F.; Li, T.Q.; Moseley, M.E.; Siebler, M.; Freund, H.J.

    2000-01-01

    We report acute and follow-up diffusion- and perfusion-weighted MRI (DWI, PWI) findings in a patient with a prolonged reversible ischaemic neurological deficit. PWI 12 h after the patient was last seen to be without symptoms revealed a large perfusion deficit in the left posterior MCA territory with a relatively inconspicuous and much smaller abnormality on DWI. Follow-up showed resolution of abnormalities on both DWI and PWI, and conventional MRI was normal, apart from a very slight abnormality, visible only on FLAIR images, at the centre of the initially DWI-positive region. These findings demonstrate the utility of PWI when be used in combination with DWI to investigate the pathophysiology of transient ischemic syndromes. (orig.)

  3. Resting quantitative cerebral blood flow in schizophrenia measured by pulsed arterial spin labeling perfusion MRI

    OpenAIRE

    Pinkham, Amy; Loughead, James; Ruparel, Kosha; Wu, Wen-Chau; Overton, Eve; Gur, Raquel; Gur, Ruben

    2011-01-01

    Arterial spin labeling imaging (ASL) perfusion MRI is a relatively novel technique that can allow for quantitative measurement of cerebral blood flow (CBF) by using magnetically labeled arterial blood water as an endogenous tracer. Available data on resting CBF in schizophrenia primarily comes from invasive and expensive nuclear medicine techniques that are often limited to small samples and yield mixed results. The noninvasive nature of ASL offers promise for larger-scale studies. The utilit...

  4. Resting cardiointegram: correlation with stress thallium perfusion studies

    International Nuclear Information System (INIS)

    Gould, L.A.; Betzu, R.; Judge, D.; Lee, J.; Taddeo, M.; Yang, D.

    1988-01-01

    The cardiointegram is a noninvasive technique for the analysis of the electrical signals of the heart obtained by a transformation of the voltage versus time format by a series of integrations. The stress thallium perfusion study is a widely used test for the detection of coronary artery disease. In order to evaluate the correlation between the resting cardiointegram and the stress thallium 201 perfusion study, 20 patients with normal resting electrocardiograms underwent stress thallium tests and resting cardiointegrams. The cardiointegram was determined on two resting complexes of leads I, II, V4, V5, and V6 and called abnormal if five of ten complexes deviated outside a normalized template. There was concordance of the cardiointegram and the thallium study in 16 of 20 patients (80%). The sensitivity for the detection of coronary artery disease was 71%, and the specificity was 80%. The overall accuracy was 74%. Thus in patients with normal electrocardiograms, the cardiointegram is a useful noninvasive test for the detection of coronary artery disease

  5. Correlation of oxygenation and perfusion sensitive MRI with invasive micro probe measurements in healthy mice brain.

    Science.gov (United States)

    Sedlacik, Jan; Reitz, Matthias; Bolar, Divya S; Adalsteinsson, Elfar; Schmidt, Nils O; Fiehler, Jens

    2015-03-01

    The non-invasive assessment of (patho-)physiological parameters such as, perfusion and oxygenation, is of great importance for the characterization of pathologies e.g., tumors, which may be helpful to better predict treatment response and potential outcome. To better understand the influence of physiological parameters on the investigated oxygenation and perfusion sensitive MRI methods, MRI measurements were correlated with subsequent invasive micro probe measurements during free breathing conditions of air, air+10% CO2 and 100% O2 in healthy mice brain. MRI parameters were the irreversible (R2), reversible (R2') and effective (R2*) transverse relaxation rates, venous blood oxygenation level assessed by quantitative blood oxygenation level dependent (qBOLD) method and cerebral blood flow (CBF) assessed by arterial spin labeling (ASL) using a 7 T small animal MRI scanner. One to two days after MRI, tissue perfusion and pO2 were measured by Laser-Doppler flowmetry and fluorescence quenching micro probes, respectively. The tissue pO2 values were converted to blood oxygen saturation by using the Hill equation. The animals were anesthetized by intra peritoneal injection of ketamine-xylazine-acepromazine (10-2-0.3 mg/ml · kg). Results for normal/hypercapnia/hyperoxia conditions were: R2[s(∧)-1] = 20.7/20.4/20.1, R2*[s(∧)-1] = 31.6/29.6/25.9, R2'[s-(∧)1] = 10.9/9.2/5.7, qBOLD venous blood oxygenation level = 0.43/0.51/0.56, CBF[ml · min(∧)-1 · 100 g(∧)-1] = 70.6/105.5/81.8, Laser-Doppler flowmetry[a.u.] = 89.2/120.2/90.6 and pO2[mmHg] = 6.3/32.3/46.7. All parameters were statistically significantly different with P effects of anesthesia and trauma due to micro probe insertion are strong confounding factors and need close attention for study planning and conduction of experiments. Investigation of the correlation of perfusion and oxygenation sensitive MRI methods with micro probe measurements in pathologic tissue such as tumors is now of compelling interest

  6. A novel method to assess pial collateralization from stroke perfusion MRI: subdividing Tmax into anatomical compartments

    International Nuclear Information System (INIS)

    Potreck, Arne; Seker, Fatih; Hoffmann, Angelika; Pfaff, Johannes; Bendszus, Martin; Heiland, Sabine; Pham, Mirko; Nagel, Simon

    2017-01-01

    To develop and validate a quantitative and observer-independent method to evaluate pial collateral circulation by DSC-perfusion MRI and test whether this novel method delivers diagnostic information which is redundant to or independent from conventional penumbra imaging by the mismatch approach. We retrospectively identified 47 patients with M1 occlusion who underwent MR diffusion/perfusion imaging and mechanical thrombectomy at our facility. By automated registration and segmentation, T max delays were attributed specifically to the pial, cortical and parenchymal compartments. The resulting pial volumes at delay were defined as the pial T max map-assessed collateral score (TMACS) and correlated with gold standard digital subtraction angiography (DSA). Mismatch ratio was assessed by conventional penumbra defining MRI criteria. Strong correlation was found between TMACS and angiographically assessed collateral score (Pearson ρ = -0.74, p < 0.001). In multiple logistic regression, both good collaterals according to TMACS [OR 4.3 (1.1-19, p = 0.04)] and mismatch ratio ≥ 3.5 [OR 12.3 (1.88-249, p = 0.03)] were independent predictors of favourable clinical outcome. Perfusion delay in the pial compartment, as evaluated by TMACS, closely reflects the extent of pial collaterals in gold-standard DSA. TMACS and mismatch ratio were found to be complementary predictors of a favourable clinical outcome, each adding independent predictive information. (orig.)

  7. Meningiomas with conventional MRI findings resembling intraaxial tumors: can perfusion-weighted MRI be helpful in differentiation?

    International Nuclear Information System (INIS)

    Hakyemez, Bahattin; Yildirim, Nalan; Erdogan, Cueneyt; Parlak, Mufit; Kocaeli, Hasan; Korfali, Ender

    2006-01-01

    To investigate the contribution of perfusion-weighted MRI to the differentiation of meningiomas with atypical conventional MRI findings from intraaxial tumors. We retrospectively analyzed 54 meningiomas, 12 glioblastomas and 13 solitary metastases. We detected 6 meningiomas with atypical features on conventional MRI resembling intraaxial tumors. The regional cerebral blood flow (rCBV) ratios of all tumors were calculated via perfusion-weighted MRI. The signal intensity-time curves were plotted and three different curve patterns were observed. The type 1 curve resembled normal brain parenchyma or the postenhancement part was minimally below the baseline, the type 2 curve was similar to the type 1 curve but with the postenhancement part above the baseline, and the type 3 curve had the postenhancement part below the baseline accompanied by widening of the curve. Student's t-test was used for statistical analysis. On CBV images meningiomas were hypervascular and the mean rCBV ratio was 10.58±2.00. For glioblastomas and metastatic lesions, the rCBV ratios were 5.02±1.40 and 4.68±1.54, respectively. There was a statistically significant difference in rCBV ratios between meningiomas and glioblastomas and metastases (P<0.001). Only one of the meningiomas displayed a type 2 curve while five showed a type 3 curve. Glioblastomas and metastases displayed either a type 1 or a type 2 curve. None of the meningiomas showed a type 1 curve and none of the glioblastomas or metastases showed a type 3 curve. (orig.)

  8. Meningiomas with conventional MRI findings resembling intraaxial tumors: can perfusion-weighted MRI be helpful in differentiation?

    Energy Technology Data Exchange (ETDEWEB)

    Hakyemez, Bahattin [Uludag University Medical School, Department of Radiology, Bursa (Turkey); Bursa State Hospital, Department of Radiology, Bursa (Turkey); Yildirim, Nalan; Erdogan, Cueneyt; Parlak, Mufit [Uludag University Medical School, Department of Radiology, Bursa (Turkey); Kocaeli, Hasan; Korfali, Ender [Uludag University Medical School, Department of Neurosurgery, Bursa (Turkey)

    2006-10-15

    To investigate the contribution of perfusion-weighted MRI to the differentiation of meningiomas with atypical conventional MRI findings from intraaxial tumors. We retrospectively analyzed 54 meningiomas, 12 glioblastomas and 13 solitary metastases. We detected 6 meningiomas with atypical features on conventional MRI resembling intraaxial tumors. The regional cerebral blood flow (rCBV) ratios of all tumors were calculated via perfusion-weighted MRI. The signal intensity-time curves were plotted and three different curve patterns were observed. The type 1 curve resembled normal brain parenchyma or the postenhancement part was minimally below the baseline, the type 2 curve was similar to the type 1 curve but with the postenhancement part above the baseline, and the type 3 curve had the postenhancement part below the baseline accompanied by widening of the curve. Student's t-test was used for statistical analysis. On CBV images meningiomas were hypervascular and the mean rCBV ratio was 10.58{+-}2.00. For glioblastomas and metastatic lesions, the rCBV ratios were 5.02{+-}1.40 and 4.68{+-}1.54, respectively. There was a statistically significant difference in rCBV ratios between meningiomas and glioblastomas and metastases (P<0.001). Only one of the meningiomas displayed a type 2 curve while five showed a type 3 curve. Glioblastomas and metastases displayed either a type 1 or a type 2 curve. None of the meningiomas showed a type 1 curve and none of the glioblastomas or metastases showed a type 3 curve. (orig.)

  9. Quantification of myocardial blood flow with dynamic perfusion 3.0 Tesla MRI: Validation with (15) O-water PET.

    Science.gov (United States)

    Tomiyama, Yuuki; Manabe, Osamu; Oyama-Manabe, Noriko; Naya, Masanao; Sugimori, Hiroyuki; Hirata, Kenji; Mori, Yuki; Tsutsui, Hiroyuki; Kudo, Kohsuke; Tamaki, Nagara; Katoh, Chietsugu

    2015-09-01

    To develop and validate a method for quantifying myocardial blood flow (MBF) using dynamic perfusion magnetic resonance imaging (MBFMRI ) at 3.0 Tesla (T) and compare the findings with those of (15) O-water positron emission tomography (MBFPET ). Twenty healthy male volunteers underwent magnetic resonance imaging (MRI) and (15) O-water positron emission tomography (PET) at rest and during adenosine triphosphate infusion. The single-tissue compartment model was used to estimate the inflow rate constant (K1). We estimated the extraction fraction of Gd-DTPA using K1 and MBF values obtained from (15) O-water PET for the first 10 subjects. For validation, we calculated MBFMRI values for the remaining 10 subjects and compared them with the MBFPET values. In addition, we compared MBFMRI values of 10 patients with coronary artery disease with those of healthy subjects. The mean resting and stress MBFMRI values were 0.76 ± 0.10 and 3.04 ± 0.82 mL/min/g, respectively, and showed excellent correlation with the mean MBFPET values (r = 0.96, P < 0.01). The mean stress MBFMRI value was significantly lower for the patients (1.92 ± 0.37) than for the healthy subjects (P < 0.001). The use of dynamic perfusion MRI at 3T is useful for estimating MBF and can be applied for patients with coronary artery disease. © 2014 Wiley Periodicals, Inc.

  10. Cardiovascular outcomes after pharmacologic stress myocardial perfusion imaging.

    Science.gov (United States)

    Lee, Douglas S; Husain, Mansoor; Wang, Xuesong; Austin, Peter C; Iwanochko, Robert M

    2016-04-01

    While pharmacologic stress single photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) is used for noninvasive evaluation of patients who are unable to perform treadmill exercise, its impact on net reclassification improvement (NRI) of prognosis is unknown. We evaluated the prognostic value of pharmacologic stress MPI for prediction of cardiovascular death or non-fatal myocardial infarction (MI) within 1 year at a single-center, university-based laboratory. We examined continuous and categorical NRI of pharmacologic SPECT-MPI for prediction of outcomes beyond clinical factors alone. Six thousand two hundred forty patients (median age 66 years [IQR 56-74], 3466 men) were studied and followed for 5963 person-years. SPECT-MPI variables associated with increased risk of cardiovascular death or non-fatal MI included summed stress score, stress ST-shift, and post-stress resting left ventricular ejection fraction ≤50%. Compared to a clinical model which included age, sex, cardiovascular disease, risk factors, and medications, model χ(2) (210.5 vs. 281.9, P statistic (0.74 vs. 0.78, P stress score, stress ST-shift and stress resting left ventricular ejection fraction). SPECT-MPI predictors increased continuous NRI by 49.4% (P 3% annualized risk of cardiovascular death or non-fatal MI, yielded a 15.0% improvement in NRI (95% CI 7.6%-27.6%, P stress MPI substantially improved net reclassification of cardiovascular death or MI risk beyond that afforded by clinical factors. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Global low perfusion and latent ischemic lesions desclosed by PET and MRI in polycythermia hypertonica

    International Nuclear Information System (INIS)

    Harada, Kiyoshi; Kameyama, Masakuni; Akiguchi, Ichiro; Fukuyama, Hidenao; Nabatame, Hidehiko

    1987-01-01

    Polycythemia hypertonica was first reported by Geisboeck in 1905 (Geisboeck's syndrome), which has been well known to accompany a high risk for cerebrovascular disorders, and relatively poor prognosis. We performed PET and MRI study on two patients with Geisboeck's syndrome. In both cases, PET study revealed that there were no focal abnormalities in cerebral blood flow (CBF) and cerebral metabolic rate for oxygen (CMRO2), but global CBF and CMRO2 decreased to low levels. On MRI study, we also found multiple small ischemic lesions in the deep structures in the cerebral hemisphere as well as brain stem, which were considered to be coincided with the perfusion territories of perforating arteries. Many of the lesions revealed by MRI were not apparent on X-ray CT scan, and were asymptomatic clinically. We consider that global low perfusion and many small latent ischemic lesions are characteristic for Geisboeck's syndrome. Therefore, it is necessary to control high hematocrit values and hypertension from an early stage of the patients with Geisboeck's syndrome. (author)

  12. Global low perfusion and latent ischemic lesions desclosed by PET and MRI in polycythemia hypertonica

    Energy Technology Data Exchange (ETDEWEB)

    Harada, K.; Kameyama, M.; Akiguchi, I.; Fukuyama, H.; Nabatame, H.

    1987-04-01

    Polycythemia hypertonica, first reported by Geisboeck in 1905 (Geisboeck's syndrome), has been known for an accompanying high risk of cerebrovascular disorders and relatively poor prognosis. We performed PET and MRI study on two patients with Geisboeck's syndrome. In both cases, PET study revealed that there were no focal abnormalities in cerebral blood flow (CBF) and cerebral metabolic rate for oxygen (CMRO/sub 2/), but global CBF and CMRO/sub 2/ decreased to low levels. On MRI study, we also found multiple small ischemic lesions in the deep structures in the cerebral hemisphere as well as brain stem, which were considered to be coincided with the perfusion territories of perforating arteries. Many of the lesions revealed by MRI were not apparent on X-ray CT scan, and were asymptomatic clinically. We consider that global low perfusion and many small latent ischemic lesions are characteristic of Geisboeck's syndrome. Therefore, it is necessary to control high hematocrit values and hypertension from an early stage of the patients with Geisboeck's syndrome.

  13. Unsupervised motion-compensation of multi-slice cardiac perfusion MRI

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Ólafsdóttir, Hildur; Larsson, Henrik B. W.

    2005-01-01

    This paper presents a novel method for registration of single and multi-slice cardiac perfusion MRI. Utilising computer intensive analyses of variance and clustering in an annotated training set off-line, the presented method is capable of providing registration without any manual interaction...... in less than a second per frame. Changes in image intensity during the bolus passage are modelled by a slice-coupled active appearance model, which is augmented with a cluster analysis of the training set. Landmark correspondences are optimised using the MDL framework due to Davies et al. Image search...

  14. Focal status epilepticus: follow-up by perfusion- and diffusion MRI

    International Nuclear Information System (INIS)

    El-Koussy, M.; Loevblad, K.O.; Kiefer, C.; Schroth, G.; Mathis, J.; Stepper, F.

    2002-01-01

    Diffusion-weighted MRI demonstrated bright right temporoparietal cortex, right hippocampus, and left cerebellum in a 63-year-old female suffering a focal convulsive status epilepticus. Hyperperfusion was noted in the right temporoparietal region. Two days later, a tendency to normalization of most of the diffusion and perfusion changes was noted, apart from the right hippocampus which became brighter on diffusion- and T2-weighted images. On the tenth day the apparent diffusion coefficient was slightly elevated, getting brighter on T2-weighted images with suspected mild post-contrast enhancement. We postulate that the discharging right hippocampus suffered cytotoxic edema, which later progressed to cell damage. (orig.)

  15. Focal status epilepticus: follow-up by perfusion- and diffusion MRI

    Energy Technology Data Exchange (ETDEWEB)

    El-Koussy, M; Loevblad, K O; Kiefer, C; Schroth, G [Department of Neuroradiology, University of Bern, Inselspital (Switzerland); Mathis, J; Stepper, F [Department of Neurology, University of Bern, Inselspital (Switzerland)

    2002-03-01

    Diffusion-weighted MRI demonstrated bright right temporoparietal cortex, right hippocampus, and left cerebellum in a 63-year-old female suffering a focal convulsive status epilepticus. Hyperperfusion was noted in the right temporoparietal region. Two days later, a tendency to normalization of most of the diffusion and perfusion changes was noted, apart from the right hippocampus which became brighter on diffusion- and T2-weighted images. On the tenth day the apparent diffusion coefficient was slightly elevated, getting brighter on T2-weighted images with suspected mild post-contrast enhancement. We postulate that the discharging right hippocampus suffered cytotoxic edema, which later progressed to cell damage. (orig.)

  16. Post-operative monitoring of tissue transfers: advantages using contrast enhanced ultrasound (CEUS) and contrast enhanced MRI (ceMRI) with dynamic perfusion analysis?

    Science.gov (United States)

    Lamby, P; Prantl, L; Fellner, C; Geis, S; Jung, E M

    2011-01-01

    The immediate evaluation of microvascular tissue flaps with respect to microcirculation after transplantation is crucial for optimal monitoring and outcome. The purpose of our investigation was to evaluate the clinical value of contrast-enhanced ultrasound (CEUS) and contrast-enhanced MRI (ceMRI) for monitoring the integrity of tissue flaps in plastic surgery. To this end, we investigated 10 patients (47 ± 16 a) between postoperative day 7 and 14 who underwent flap surgery in order to cover tissue defects in various body regions. For CEUS we utilized the GE LOGIQ E9 equipped with a linear transducer (6-9 MHz). After application of 2.4 ml SonoVue, the tissue perfusion was detected in Low MI-Technique (MI present, both technologies provide an optimal assessment of perfusion in cutaneous, subcutaneous and muscle tissue layers, whereby the detection of fatty tissue perfusion is currently more easily detected using CEUS compared to ceMRI.

  17. Quantification of the effect of water exchange in dynamic contrast MRI perfusion measurements in the brain and heart

    DEFF Research Database (Denmark)

    Larsson, H B; Rosenbaum, S; Fritz-Hansen, T

    2001-01-01

    Measurement of myocardial and brain perfusion when using exogenous contrast agents (CAs) such as gadolinium-DTPA (Gd-DTPA) and MRI is affected by the diffusion of water between compartments. This water exchange may have an impact on signal enhancement, or, equivalently, on the longitudinal...... exchange can have a significant effect on perfusion estimation (F) in the brain when using Gd-DTPA, where it acts as an intravascular contrast agent....

  18. Visual cortex reactivity in sedated children examined with perfusion MRI (FAIR)

    DEFF Research Database (Denmark)

    Born, A.P.; Rostrup, Egill; Miranda Gimenez-Ricco, Maria Jo

    2002-01-01

    Sleeping and sedated children can respond to visual stimulation with a decrease in blood oxygenation level dependent (BOLD) functional MRI signal response. The contribution of metabolic and hemodynamic parameters to this inverse signal response is incompletely understood. It has been hypothesized...... that it is caused by a relatively greater increase of oxygen consumption compared to rCBF (regional cerebral blood flow) increase. We studied the rCBF changes during visual stimulation in four sedated children, aged 4-71 months, and four alert adults, with an arterial water spin labeling technique (FAIR) and BOLD f.......99-2.93), respectively. Thus, in the children, an rCBF increase could not be detected by perfusion MRI, but indications of a FAIR signal decrease were found. An rCBF decrease in the primary visual cortex during stimulation has not been reported previously, but it is a possible explanation for the negative BOLD response...

  19. Correlation of oxygenation and perfusion sensitive MRI with invasive micro probe measurements in healthy mice brain

    International Nuclear Information System (INIS)

    Sedlacik, Jan; Fiehler, Jens; Reitz, Matthias; Schmidt, Nils O.; Bolar, Divya S.; Adalsteinsson, Elfar

    2015-01-01

    The non-invasive assessment of (patho-)physiological parameters such as, perfusion and oxygenation, is of great importance for the characterization of pathologies e.g., tumors, which may be helpful to better predict treatment response and potential outcome. To better understand the influence of physiological parameters on the investigated oxygenation and perfusion sensitive MRI methods, MRI measurements were correlated with subsequent invasive micro probe measurements during free breathing conditions of air, air+10% CO2 and 100% O2 in healthy mice brain. MRI parameters were the irreversible (R2), reversible (R2') and effective (R2*) transverse relaxation rates, venous blood oxygenation level assessed by quantitative blood oxygenation level dependent (qBOLD) method and cerebral blood flow (CBF) assessed by arterial spin labeling (ASL) using a 7T small animal MRI scanner. One to two days after MRI, tissue perfusion and pO2 were measured by Laser-Doppler flowmetry and fluorescence quenching micro probes, respectively. The tissue pO2 values were converted to blood oxygen saturation by using the Hill equation. The animals were anesthetized by intra peritoneal injection of ketamine-xylazine-acepromazine (10-2-0.3 mg/ml.kg). Results for normal/hypercapnia/hyperoxia conditions were: R2[s and -1] = 20.7/20.4/20.1, R2*[s and -1] = 31.6/29.6/25.9, R2'[s and 1] = 10.9/9.2/5.7, qBOLD venous blood oxygenation level = 0.43/0.51/0.56, CBF[ml.min and -1.100g and -1] = 70.6/105.5/81.8, Laser-Doppler flowmetry[a.u.] = 89.2/120.2/90.6 and pO2[mmHg] = 6.3/32.3/46.7. All parameters were statistically significantly different with P < 0.001 between all breathing conditions. All MRI and the corresponding micro probe measurements were also statistically significantly (P ≤ 0.03) correlated with each other. However, converting the tissue pO2 to blood oxygen saturation = 0.02/0.34/0.63, showed only very limited agreement with the qBOLD venous blood oxygenation level. We found good

  20. Correlation of oxygenation and perfusion sensitive MRI with invasive micro probe measurements in healthy mice brain

    Energy Technology Data Exchange (ETDEWEB)

    Sedlacik, Jan; Fiehler, Jens [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Neuroradiology; Reitz, Matthias; Schmidt, Nils O. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Neurosurgery; Bolar, Divya S. [Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA (United States). Radiology; Adalsteinsson, Elfar [Massachusetts Institute of Technology, Cambridge, MA (United States). Electrical Engineering and Computer Science

    2015-05-01

    The non-invasive assessment of (patho-)physiological parameters such as, perfusion and oxygenation, is of great importance for the characterization of pathologies e.g., tumors, which may be helpful to better predict treatment response and potential outcome. To better understand the influence of physiological parameters on the investigated oxygenation and perfusion sensitive MRI methods, MRI measurements were correlated with subsequent invasive micro probe measurements during free breathing conditions of air, air+10% CO2 and 100% O2 in healthy mice brain. MRI parameters were the irreversible (R2), reversible (R2') and effective (R2*) transverse relaxation rates, venous blood oxygenation level assessed by quantitative blood oxygenation level dependent (qBOLD) method and cerebral blood flow (CBF) assessed by arterial spin labeling (ASL) using a 7T small animal MRI scanner. One to two days after MRI, tissue perfusion and pO2 were measured by Laser-Doppler flowmetry and fluorescence quenching micro probes, respectively. The tissue pO2 values were converted to blood oxygen saturation by using the Hill equation. The animals were anesthetized by intra peritoneal injection of ketamine-xylazine-acepromazine (10-2-0.3 mg/ml.kg). Results for normal/hypercapnia/hyperoxia conditions were: R2[s {sup and} -1] = 20.7/20.4/20.1, R2*[s {sup and} -1] = 31.6/29.6/25.9, R2'[s {sup and} 1] = 10.9/9.2/5.7, qBOLD venous blood oxygenation level = 0.43/0.51/0.56, CBF[ml.min {sup and} -1.100g {sup and} -1] = 70.6/105.5/81.8, Laser-Doppler flowmetry[a.u.] = 89.2/120.2/90.6 and pO2[mmHg] = 6.3/32.3/46.7. All parameters were statistically significantly different with P < 0.001 between all breathing conditions. All MRI and the corresponding micro probe measurements were also statistically significantly (P ≤ 0.03) correlated with each other. However, converting the tissue pO2 to blood oxygen saturation = 0.02/0.34/0.63, showed only very limited agreement with the qBOLD venous blood

  1. Investigating tumor perfusion by hyperpolarized (13) C MRI with comparison to conventional gadolinium contrast-enhanced MRI and pathology in orthotopic human GBM xenografts

    DEFF Research Database (Denmark)

    Park, Ilwoo; von Morze, Cornelius; Lupo, Janine M

    2016-01-01

    glioblastoma (GBM) model for the characterization of tumor perfusion and compared with standard Gd-based dynamic susceptibility contrast (DSC) MRI data and immunohistochemical analysis from resected brains. Distinct HMCP perfusion characteristics were observed within the GBM tumors compared with contralateral...... for tumor that exhibited high levels of hyperpolarized HMCP signal. The results from this study have demonstrated that hyperpolarized HMCP data can be used as an indicator of tumor perfusion in an orthotopic xenograft model for GBM. Magn Reson Med, 2016. © 2016 Wiley Periodicals, Inc....

  2. Simultaneous detection of landmarks and key-frame in cardiac perfusion MRI using a joint spatial-temporal context model

    Science.gov (United States)

    Lu, Xiaoguang; Xue, Hui; Jolly, Marie-Pierre; Guetter, Christoph; Kellman, Peter; Hsu, Li-Yueh; Arai, Andrew; Zuehlsdorff, Sven; Littmann, Arne; Georgescu, Bogdan; Guehring, Jens

    2011-03-01

    Cardiac perfusion magnetic resonance imaging (MRI) has proven clinical significance in diagnosis of heart diseases. However, analysis of perfusion data is time-consuming, where automatic detection of anatomic landmarks and key-frames from perfusion MR sequences is helpful for anchoring structures and functional analysis of the heart, leading toward fully automated perfusion analysis. Learning-based object detection methods have demonstrated their capabilities to handle large variations of the object by exploring a local region, i.e., context. Conventional 2D approaches take into account spatial context only. Temporal signals in perfusion data present a strong cue for anchoring. We propose a joint context model to encode both spatial and temporal evidence. In addition, our spatial context is constructed not only based on the landmark of interest, but also the landmarks that are correlated in the neighboring anatomies. A discriminative model is learned through a probabilistic boosting tree. A marginal space learning strategy is applied to efficiently learn and search in a high dimensional parameter space. A fully automatic system is developed to simultaneously detect anatomic landmarks and key frames in both RV and LV from perfusion sequences. The proposed approach was evaluated on a database of 373 cardiac perfusion MRI sequences from 77 patients. Experimental results of a 4-fold cross validation show superior landmark detection accuracies of the proposed joint spatial-temporal approach to the 2D approach that is based on spatial context only. The key-frame identification results are promising.

  3. Renal Cell Carcinoma Perfusion before and after Radiofrequency Ablation Measured with Dynamic Contrast Enhanced MRI: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Tze Min Wah

    2018-01-01

    Full Text Available Aim: To investigate if the early treatment effects of radiofrequency ablation (RFA on renal cell carcinoma (RCC can be detected with dynamic contrast enhanced (DCE-MRI and to correlate RCC perfusion with RFA treatment time. Materials and methods: 20 patients undergoing RFA of their 21 RCCs were evaluated with DCE-MRI before and at one month after RFA treatment. Perfusion was estimated using the maximum slope technique at two independent sittings. Total RCC blood flow was correlated with total RFA treatment time, tumour location, size and histology. Results: DCE-MRI examinations were successfully evaluated for 21 RCCs (size from 1.3 to 4 cm. Perfusion of the RCCs decreased significantly (p < 0.0001 from a mean of 203 (±80 mL/min/100 mL before RFA to 8.1 (±3.1 mL/min/100 mL after RFA with low intra-observer variability (r ≥ 0.99, p < 0.0001. There was an excellent correlation (r = 0.95 between time to complete ablation and pre-treatment total RCC blood flow. Tumours with an exophytic location exhibit the lowest mean RFA treatment time. Conclusion: DCE-MRI can detect early treatment effects by measuring RCC perfusion before and after RFA. Perfusion significantly decreases in the zone of ablation, suggesting that it may be useful for the assessment of treatment efficacy. Pre-RFA RCC blood flow may be used to predict RFA treatment time.

  4. Parametric Response Maps of Perfusion MRI May Identify Recurrent Glioblastomas Responsive to Bevacizumab and Irinotecan

    Science.gov (United States)

    Aquino, Domenico; Cuppini, Lucia; Anghileri, Elena; Finocchiaro, Gaetano; Bruzzone, Maria Grazia; Eoli, Marica

    2014-01-01

    Background Perfusion weighted imaging (PWI) can be used to measure key aspects of tumor vascularity in vivo and recent studies suggest that perfusion imaging may be useful in the early assessment of response to angiogenesis inhibitors. Aim of this work is to compare Parametric Response Maps (PRMs) with the Region Of Interest (ROI) approach in the analysis of tumor changes induced by bevacizumab and irinotecan in recurrent glioblastomas (rGBM), and to evaluate if changes in tumor blood volume measured by perfusion MRI may predict clinical outcome. Methods 42 rGBM patients with KPS ≥50 were treated until progression, as defined by MRI with RANO criteria. Relative cerebral blood volume (rCBV) variation after 8 weeks of treatment was calculated through semi-automatic ROI placement in the same anatomic region as in baseline. Alternatively, rCBV variations with respect to baseline were calculated into the evolving tumor region using a voxel-by-voxel difference. PRMs were created showing where rCBV significantly increased, decreased or remained unchanged. Results An increased blood volume in PRM (PRMCBV+) higher than 18% (first quartile) after 8 weeks of treatment was associated with increased progression free survival (PFS; 24 versus 13 weeks, p = 0.045) and overall survival (OS; 38 versus 25 weeks, p = 0.016). After 8 weeks of treatment ROI analysis showed that mean rCBV remained elevated in non responsive patients (4.8±0.9 versus 5.1±1.2, p = 0.38), whereas decreased in responsive patients (4.2±1.3 versus 3.8±1.6 p = 0.04), and re-increased progressively when patients approached tumor progression. Conclusions Our data suggest that PRMs can provide an early marker of response to antiangiogenic treatment and warrant further confirmation in a larger cohort of GBM patients. PMID:24675671

  5. Quantitative Myocardial Perfusion with Dynamic Contrast-Enhanced Imaging in MRI and CT: Theoretical Models and Current Implementation

    Directory of Open Access Journals (Sweden)

    G. J. Pelgrim

    2016-01-01

    Full Text Available Technological advances in magnetic resonance imaging (MRI and computed tomography (CT, including higher spatial and temporal resolution, have made the prospect of performing absolute myocardial perfusion quantification possible, previously only achievable with positron emission tomography (PET. This could facilitate integration of myocardial perfusion biomarkers into the current workup for coronary artery disease (CAD, as MRI and CT systems are more widely available than PET scanners. Cardiac PET scanning remains expensive and is restricted by the requirement of a nearby cyclotron. Clinical evidence is needed to demonstrate that MRI and CT have similar accuracy for myocardial perfusion quantification as PET. However, lack of standardization of acquisition protocols and tracer kinetic model selection complicates comparison between different studies and modalities. The aim of this overview is to provide insight into the different tracer kinetic models for quantitative myocardial perfusion analysis and to address typical implementation issues in MRI and CT. We compare different models based on their theoretical derivations and present the respective consequences for MRI and CT acquisition parameters, highlighting the interplay between tracer kinetic modeling and acquisition settings.

  6. The precision of DCE-MRI using the tissue homogeneity model with continuous formulation of the perfusion parameters

    Czech Academy of Sciences Publication Activity Database

    Bartoš, Michal; Jiřík, Radovan; Kratochvíla, Jiří; Standara, M.; Starčuk jr., Zenon; Torfinn, T.

    2014-01-01

    Roč. 32, č. 5 (2014), s. 505-513 ISSN 0730-725X R&D Projects: GA ČR GAP102/12/2380; GA MŠk ED0017/01/01; GA MŠk(CZ) LO1212 Institutional support: RVO:67985556 ; RVO:68081731 Keywords : dynamic contrast-enhanced MRI (DCE-MRI) * perfusion * parameter estimation * bolus arrival time Subject RIV: FS - Medical Facilities ; Equipment Impact factor: 2.090, year: 2014

  7. A capillary-based perfusion phantom for simulation of brain perfusion for MRI; Ein kapillarbasiertes Phantom zur Simulation der Gehirnperfusion mit der Magnet-Resonanz-Tomografie

    Energy Technology Data Exchange (ETDEWEB)

    Maciak, A.; Kronfeld, A.; Mueller-Forell, W. [Universitaetsklinikum Mainz (Germany). Inst. fuer Neuroradiologie; Wille, C. [Fachhochschule Bingen (Germany). Inst. fuer Informatik; Kempski, O. [Universitaetsklinikum Mainz (Germany). Inst. fuer Neurochirurgische Pathophysiologie; Stoeter, P. [CEDIMAT, Santo Domingo (Dominican Republic). Inst. of Neuroradiology

    2010-10-15

    Purpose: The measurement of the CBF is a non-standardized procedure and there are no reliable gold standards. This abstract shows a capillary-based perfusion-phantom for CE-DSC-MRI. It has equivalent flow properties to those within the tissue capillary system of the human brain and allows the validation of the Siemens Perfusion (MR) software. Materials and Methods: The perfusion phantom consists of a dialyzer for the simulation of the capillary system, a feeding tube for simulation of the AIF and a pulsatile pump for simulation of the heart. Using this perfusion phantom, the exact determination of the gold standard CBF due to the well-known geometry of the phantom is easy. It was validated based on different perfusion measurements. These measurements were investigated with standard software (Siemens Perfusion MR). The software determined the CBF within the capillary system. Based on this CBF, a comparison to the gold standard was made with several different flow speeds. After AIF selection, a total of 726 CBF data points were automatically extracted by the software. Results: This results in a comparison of the gold standard CBF to these 726 CBF values. Therefore, a reproducible and reliable deviation estimation between gold standard CBF and measured CBF using the software was computed. It can be shown that the deviation between gold standard and software-based evaluation ranges between 1 and 31 %. Conclusion: There is no significance for any correlation between flow speed and amount of deviation. The mean measured CBF is 11.4 % higher than the gold standard CBF (p-value < 0.001). Using this kind of perfusion-phantom, the validation of different software systems allows reliable conclusions about their quality. (orig.)

  8. Perfusion characteristics of late radiation injury of parotid glands: quantitative evaluation with dynamic contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Juan, Chun-Jung; Chen, Cheng-Yu.; Hsueh, Chun-Jen; Huang, Guo-Shu; Jen, Yee-Min; Liu, Hua-Shan; Wang, Chao-Ying; Chung, Hsiao-Wen; Liu, Yi-Jui; Chou, Yu-Ching; Chai, Yao-Te

    2009-01-01

    We aimed to quantitatively investigate the alteration of parotid perfusion after irradiation using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) based on a two-compartment tracer kinetic model. This study enrolled 19 patients (53.2±14.9 years) treated by head and neck radiotherapy and 19 age-relevant and sex-matched subjects as a control group. Perfusion parameters (K el , k 21 and A) of parotid glands were analyzed based on the Brix model from T1-weighted DCE-MRI. Suitability of the Brix model was evaluated via Monte Carlo simulation for the goodness-of-fit. Analysis of nonlinear goodness-of-fit showed that the Brix model is appropriate in evaluating the parotid perfusion (R 2 = 0.938±0.050). The irradiated parotid glands showed significantly lower K el (P 21 (P < 0.05) and consequently significantly higher value of peak enhancement (P<0.0005) and time-to-peak (P<0.0005) compared with non-irradiated ones, suggestive of gradual and prolonged accumulation and delayed wash-out of contrast agent due to increased extracellular extravascular space and decreased vascular permeability in the irradiated glands. Linear regression analysis showed dose-dependent perfusion changes of the irradiated parotid glands. We conclude that quantitative DCE-MRI is a potential tool in investigating parotid gland perfusion changes after radiotherapy. (orig.)

  9. Temporal evolution of ischemic lesions in nonhuman primates: a diffusion and perfusion MRI study.

    Directory of Open Access Journals (Sweden)

    Xiaodong Zhang

    Full Text Available Diffusion-weighted imaging (DWI and perfusion MRI were used to examine the spatiotemporal evolution of stroke lesions in adult macaques with ischemic occlusion.Permanent MCA occlusion was induced with silk sutures through an interventional approach via the femoral artery in adult rhesus monkeys (n = 8, 10-21 years old. The stroke lesions were examined with high-resolution DWI and perfusion MRI, and T2-weighted imaging (T2W on a clinical 3T scanner at 1-6, 48, and 96 hours post occlusion and validated with H&E staining.The stroke infarct evolved via a natural logarithmic pattern with the mean infarct growth rate = 1.38 ± 1.32 ml per logarithmic time scale (hours (n = 7 in the hyperacute phase (1-6 hours. The mean infarct volume after 6 hours post occlusion was 3.6±2.8 ml (n = 7, by DWI and increased to 3.9±2.9 ml (n = 5, by T2W after 48 hours, and to 4.7±2.2ml (n = 3, by T2W after 96 hours post occlusion. The infarct volumes predicted by the natural logarithmic function were correlated significantly with the T2W-derived lesion volumes (n = 5, r = 0.92, p = 0.01 at 48 hours post occlusion. The final infarct volumes derived from T2W were correlated significantly with those from H&E staining (r = 0.999, p < 0.0001, n = 4. In addition, the diffusion-perfusion mismatch was visible generally at 6 hours but nearly diminished at 48 hours post occlusion.The infarct evolution follows a natural logarithmic pattern in the hyperacute phase of stroke. The logarithmic pattern of evolution could last up to 48 hours after stroke onset and may be used to predict the infarct volume growth during the acute phase of ischemic stroke. The nonhuman primate model, MRI protocols, and post data processing strategy may provide an excellent platform for characterizing the evolution of acute stroke lesion in mechanistic studies and therapeutic interventions of stroke disease.

  10. MDMA ‘ecstasy’ increases cerebral cortical perfusion determined by bolus-tracking arterial spin labelling (btASL) MRI

    Science.gov (United States)

    Rouine, J; Gobbo, O L; Campbell, M; Gigliucci, V; Ogden, I; McHugh Smith, K; Duffy, P; Behan, B; Byrne, D; Kelly, M E; Blau, C W; Kerskens, C M; Harkin, A

    2013-01-01

    Background and Purpose The purpose of this study was to assess cerebral perfusion changes following systemic administration of the recreational drug 3,4-methylendioxymethamphetamine (MDMA ‘ecstasy’) to rats. Experimental Approach Cerebral perfusion was quantified using bolus-tracking arterial spin labelling (btASL) MRI. Rats received MDMA (20 mg·kg−1; i.p.) and were assessed 1, 3 or 24 h later. Rats received MDMA (5 or 20 mg·kg−1; i.p.) and were assessed 3 h later. In addition, rats received MDMA (5 or 10 mg·kg−1; i.p.) or saline four times daily over 2 consecutive days and were assessed 8 weeks later. Perfusion-weighted images were generated in a 7 tesla (7T) MRI scanner and experimental data was fitted to a quantitative model of cerebral perfusion to generate mean transit time (MTT), capillary transit time (CTT) and signal amplitude. Key Results MDMA reduces MTT and CTT and increases amplitude in somatosensory and motor cortex 1 and 3 h following administration, indicative of an increase in perfusion. Prior exposure to MDMA provoked a long-term reduction in cortical 5-HT concentration, but did not produce a sustained effect on cerebral cortical perfusion. The response to acute MDMA challenge (20 mg·kg−1; i.p.) was attenuated in these animals indicating adaptation in response to prior MDMA exposure. Conclusions and Implications MDMA provokes changes in cortical perfusion, which are quantifiable by btASL MRI, a neuroimaging tool with translational potential. Future studies are directed towards elucidation of the mechanisms involved and correlating changes in cerebrovascular function with potential behavioural deficits associated with drug use. PMID:23517012

  11. Clinical evaluation of pulmonary perfusion MRI using FAIR (flow-sensitive alternating inversion recovery)-HASTE (Half-Fourier Single-Shot TurboSE) method

    International Nuclear Information System (INIS)

    Togami, Izumi; Sasai, Nobuya; Tsunoda, Masatoshi; Sei, Tetsurou; Sato, Shuhei; Yabuki, Takayuki; Hiraki, Yoshio

    2002-01-01

    The FAIR-HASTE method is a kind of noninvasive perfusion MR imaging obtained without the use of contrast media. By subtracting a flow-insensitive image from a flow-sensitive image, contrast enhancement of inflowing blood achieved. In the present study, we applied pulmonary perfusion FAIR-HASTE sequence for 23 patients with various pulmonary diseases, and compared the findings with those by pulmonary perfusion scintigraphy and Gadolinium perfusion MRI. Pulmonary perfusion imaging with the FAIR-HASTE method was possible in all clinical cases, and the findings corresponded well to those obtained by perfusion MRI using contrast media or pulmonary scintigraphy. The FAIR-HASTE method is a promising method for the evaluation of pulmonary perfusion. (author)

  12. Visual Assessment of Brain Perfusion MRI Scans in Dementia: A Pilot Study.

    Science.gov (United States)

    Fällmar, David; Lilja, Johan; Velickaite, Vilma; Danfors, Torsten; Lubberink, Mark; Ahlgren, André; van Osch, Matthias J P; Kilander, Lena; Larsson, Elna-Marie

    2016-05-01

    Functional imaging is becoming increasingly important for the detection of neurodegenerative disorders. Perfusion MRI with arterial spin labeling (ASL) has been reported to provide promising diagnostic possibilities but is not yet widely used in routine clinical work. The aim of this study was to compare, in a clinical setting, the visual assessment of subtracted ASL CBF maps with and without additional smoothing, to FDG-PET data. Ten patients with a clinical diagnosis of dementia and 11 age-matched cognitively healthy controls were examined with pseudo-continuous ASL (pCASL) and 18F-Fluorodeoxyglucose positron emission tomography (FDG-PET). Three diagnostic physicians visually assessed the pCASL maps after subtraction only, and after postprocessing using Gaussian smoothing and GLM-based beta estimate functions. The assessment scores were compared to FDG PET values. Furthermore, the ability to discriminate patients from healthy elderly controls was assessed. Smoothing improved the correlation between visually assessed regional ASL perfusion scores and the FDG PET SUV-r values from the corresponding regions. However, subtracted pCASL maps discriminated patients from healthy controls better than smoothed maps. Smoothing increased the number of false-positive patient identifications. Application of beta estimate functions had only a marginal effect. Spatial smoothing of ASL images increased false positive results in the discrimination of hypoperfusion conditions from healthy elderly. It also decreased interreader agreement. However, regional characterization and subjective perception of image quality was improved. Copyright © 2015 by the American Society of Neuroimaging.

  13. Comparative utility of MRI perfusion with MSIDR and DWIBS for the characterization of breast tumors

    International Nuclear Information System (INIS)

    Zhang, Bing; Zhu, Bin; Li, Ming

    2012-01-01

    Background. In recent years, breast magnetic resonance imaging (MRI) has been used to evaluate the morphology and functional markers of breast lesions, which might influence local staging and surgical planning. Purpose. To evaluate the feasibility of a one stop MRI protocol combined with diffusion-weighted imaging with background body signal suppression (DWIBS), T2*-weighted perfusion imaging (T2*-PWI) and delayed contrast-enhanced T1-weighted MRI (T1W-C+). Material and Methods. All experiments were conducted with a 3-T clinical MRI scanner. The apparent diffusion coefficient (ADC) and detectability of lesions in DWIBS, the maximal signal intensity drop rate (MSIDR) in T2*-PWI and the intensity increasing rate (IIR) on T1W-C+ were compared between breast malignancies (n = 29) and benign lesions (n = 31). The time-signal curves in the T2*-PWI sequences were classified into two subtypes (a and b) according to the end of the curve. The ADC, MSIDR, the first maximal signal intensity decrease time (MSIDT), and IIR between the malignant and benign lesions were statistically analyzed by unpaired t-tests. Results. Overall, 90% of the lesions were detected by DWIBS. There were significant differences in ADC, MSIDR, and IIR between the carcinomas and benign lesions. The Ib subtype in T2*-PWI demonstrated a specificity of 66.7% in differentiating between carcinomas and benign lesions. At a fixed specificity of 93.5%, the MSIDR, IIR, and ADC differentiated breast carcinomas from benign lesions with sensitivities of 82.8%, 44.8%, and 86.2%, respectively. Conclusion. DWIBS might be a compensation sequence for detecting breast lesions in pre-contrast sequences. MSIDR from T2*-PWI had the best specificity index, and the two subtypes in the T2*-PWI curve were helpful in the differential diagnosis of carcinomas from benign lesions

  14. Diagnostic performance of stress myocardial perfusion imaging for coronary artery disease: a systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Jong, Marcus C. de; Genders, Tessa S.S.; Geuns, Robert-Jan van; Moelker, Adriaan; Hunink, M.G.M.

    2012-01-01

    To determine and compare the diagnostic performance of stress myocardial perfusion imaging (MPI) for the diagnosis of obstructive coronary artery disease (CAD), using conventional coronary angiography (CCA) as the reference standard. We searched Medline and Embase for literature that evaluated stress MPI for the diagnosis of obstructive CAD using magnetic resonance imaging (MRI), contrast-enhanced echocardiography (ECHO), single-photon emission computed tomography (SPECT) and positron emission tomography (PET). All pooled analyses were based on random effects models. Articles on MRI yielded a total of 2,970 patients from 28 studies, articles on ECHO yielded a sample size of 795 from 10 studies, articles on SPECT yielded 1,323 from 13 studies. For CAD defined as either at least 50 %, at least 70 % or at least 75 % lumen diameter reduction on CCA, the natural logarithms of the diagnostic odds ratio (lnDOR) for MRI (3.63; 95 % CI 3.26-4.00) was significantly higher compared to that of SPECT (2.76; 95 % CI 2.28-3.25; P = 0.006) and that of ECHO (2.83; 95 % CI 2.29-3.37; P = 0.02). There was no significant difference between the lnDOR of SPECT and ECHO (P = 0.52). Our results suggest that MRI is superior for the diagnosis of obstructive CAD compared with ECHO and SPECT. ECHO and SPECT demonstrated similar diagnostic performance. (orig.)

  15. What’s the clinical significance of adding diffusion and perfusion MRI in the differentiation of glioblastoma multiforme and solitary brain metastasis?

    Directory of Open Access Journals (Sweden)

    Amr F. Mourad

    2017-09-01

    Full Text Available Objective: To evaluate the additional diagnostic value of diffusion and perfusion MRI in the differentiation of glioblastoma multiforme (GBM and solitary brain metastasis. Patients and methods: This retrospective study included 24 patients with histologically proven brain tumors who underwent conventional MRI with analysis of diffusion (DWI and perfusion (PWI MRI findings of each tumor. The Apparent Diffusion Coefficient (ADC values were calculated in the minimum (ADC-MIN, mean (ADC-MEAN, and maximum (ADC-MAX in all the tumors and the peritumoral regions. The PWI data was expressed as maximum regional cerebral blood volume (rCBV of the tumors and peritumoral regions. Results: After adding diffusion and perfusion to conventional MRI findings, we found that the accuracy of differentiation between glioblastoma multiforme (GBM and solitary metastasis increased from 70% to 90%.There is a significant difference in DWI signal intensity between GBM and metastatic tumors (P < 0.05. The ADC values of GBM were lower than that of metastatic tumors. On perfusion MRI, the maximum rCBV of the peritumoral region (rCBVP of GBM was higher than that of brain metastases (P < 0.001. Conclusion: The addition of diffusion and perfusion to the MRI protocol increases the accuracy of differentiation between GBM and solitary brain metastasis and should be considered routinely. Keywords: Diffusion MRI, Perfusion MRI, GBM, Solitary brain metastases

  16. Effects of perfusion detect on the measurement of left ventricular mass, ventricular volume and post-stress left ventricular ejection fraction in gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Ahn, Byeong Cheol; Bae, Sun Keun; Lee, Sang Woo; Jeong, Sin Young; Lee, Jae Tae; Lee, Kyu Bo

    2002-01-01

    The presence of perfusion defect may influence the left ventricular mass (LVM) measurement by quantitative gated myocardial perfusion SPECT (QGS), and ischemic myocardium, usually showing perfusion defect may produce post-stress LV dysfunction. This study was aimed to evaluated the effects of extent and reversibility of perfusion defect on the automatic measurement of LVM by QGS and to investigate the effect of reversibility of perfusion defect on post-stress LV dysfunction. Forty-six patients (male/female=34:12, mean age=64 years) with perfusion defect on myocardial perfusion SPECT underwent rest and post-stress QGS. Forty patients (87%) showed reversible defect. End-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (EF), and LV myocardial volume were obtained from QGS by autoquant program, and LVM was calculated by multiplying the LV myocardial volume by the specific gravity of myocardium. LVMs measured at rest and post-stress QGS showed good correlation, and higher correlation was founded in the subjects with fixed perfusion defect and with small defect (smaller than 20%). There were no significant differences in EDVs, ESVs and EFs between obtained by rest and post-stress QGS in patients with fixed myocardial defect. Whereas, EF obtained by post-stress QGS was lower than that by rest QGS in patients with reversible defect and 10 (25%) of them showed decreases in EF more than 5% in post-stress QGS, as compared to that of rest QGS. Excellent correlations of EDVs, ESVs, EFs between rest and post-stress QGS were noted. Patients with fixed defect had higher correlation between defect can affect LVM measurement by QGS and patients with reversible defect shows post-stress LV dysfunction more frequently than patients with fixed perfusion defect

  17. Role of FDG-PET/MRI, FDG-PET/CT, and Dynamic Susceptibility Contrast Perfusion MRI in Differentiating Radiation Necrosis from Tumor Recurrence in Glioblastomas.

    Science.gov (United States)

    Hojjati, Mojgan; Badve, Chaitra; Garg, Vasant; Tatsuoka, Curtis; Rogers, Lisa; Sloan, Andrew; Faulhaber, Peter; Ros, Pablo R; Wolansky, Leo J

    2018-01-01

    To compare the utility of quantitative PET/MRI, dynamic susceptibility contrast (DSC) perfusion MRI (pMRI), and PET/CT in differentiating radiation necrosis (RN) from tumor recurrence (TR) in patients with treated glioblastoma multiforme (GBM). The study included 24 patients with GBM treated with surgery, radiotherapy, and temozolomide who presented with progression on imaging follow-up. All patients underwent PET/MRI and pMRI during a single examination. Additionally, 19 of 24 patients underwent PET/CT on the same day. Diagnosis was established by pathology in 17 of 24 and by clinical/radiologic consensus in 7 of 24. For the quantitative PET/MRI and PET/CT analysis, a region of interest (ROI) was drawn around each lesion and within the contralateral white matter. Lesion to contralateral white matter ratios for relative maximum, mean, and median were calculated. For pMRI, lesion ROI was drawn on the cerebral blood volume (CBV) maps and histogram metrics were calculated. Diagnostic performance for each metric was assessed using receiver operating characteristic curve analysis and area under curve (AUC) was calculated. In 24 patients, 28 lesions were identified. For PET/MRI, relative mean ≥ 1.31 resulted in AUC of .94 with both sensitivity and negative predictive values (NPVs) of 100%. For pMRI, CBV max ≥3.32 yielded an AUC of .94 with both sensitivity and NPV measuring 100%. The joint model utilizing r-mean (PET/MRI) and CBV mode (pMRI) resulted in AUC of 1.0. Our study demonstrates that quantitative PET/MRI parameters in combination with DSC pMRI provide the best diagnostic utility in distinguishing RN from TR in treated GBMs. © 2017 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.

  18. Myocordial perfusion SPECT with dipyridamole stress test in cardiac syndrome X

    International Nuclear Information System (INIS)

    Czepczynski, R.; Smolarek, I.; Sowinski, J.; Rogacka, D.; Kazmierczak, M.; Wysocki, H.

    2006-01-01

    Cardiac syndrome X defines patients with typical anginal chest pain, a positive exercise ECG stress test and angiographically normal coronary arteries. Aim of this study was to evaluate the role of myocardial perfusion SPECT with dipyridamole stress in the diagnosis of cardiac syndrome X. Patients, methods: 68 patients with syndrome X aged 32 to 60 years were subjected to myocardial imaging using 99m Tc-MIBI according to the two-days protocol: at rest and after dipyridamole infusion. Semiquantitative evaluation of the images was based on the assessment of 99m Tc-MIBI uptake in 17 myocardial segments using a 5-points scale (0 point - normal uptake, 4 points - no uptake). Scores obtained in each segment were summed up, constituting the summed rest score (SRS) and summed stress score (SSS). Results: mean SRS was 7.9 ± 4.8 and mean SSS was 7.2 ± 4.4 (non-significant difference). Individual comparison of SRS and SSS values revealed three patterns of scintigraphic images: (1) in 25 patients (36.8%), a paradoxical improvement of perfusion at stress images was found, (2) in 23 patients (33.8%), the myocardial perfusion deteriorated after dipyridamole, (3) in 20 patients (29.4%), no significant change of the myocordial perfusion between rest and stress images occurred. Conclusions: in cardiac syndrome X, myocardial SPECT with dipyridamole stress shows different patterns of myocardial perfusion that reflects heterogeneity of this pathology. (orig.)

  19. Bevacizumab treatment in malignant meningioma with additional radiation necrosis. An MRI diffusion and perfusion case study

    Energy Technology Data Exchange (ETDEWEB)

    Bostroem, J.P. [University of Bonn Medical Center, Department of Neurosurgery, Bonn (Germany); MediClin Robert Janker Clinic and MVZ MediClin, Department of Radiosurgery and Stereotactic Radiotherapy, Bonn (Germany); Seifert, M.; Greschus, S. [University of Bonn Medical Center, Department of Radiology, Bonn (Germany); Schaefer, N.; Herrlinger, U. [University of Bonn Medical Center, Division of Clinical Neurooncology, Department of Neurology, Bonn (Germany); Glas, M. [University of Bonn Medical Center, Division of Clinical Neurooncology, Department of Neurology, Bonn (Germany); University of Bonn Medical Center, Stem Cell Pathologies, Institute of Reconstructive Neurobiology, Bonn (Germany); MediClin Robert Janker Clinic, Clinical Cooperation Unit Neurooncology, Bonn (Germany); Lammering, G. [MediClin Robert Janker Clinic and MVZ MediClin, Department of Radiosurgery and Stereotactic Radiotherapy, Bonn (Germany); MediClin Robert Janker Clinic, Clinical Cooperation Unit Neurooncology, Bonn (Germany); Heinrich-Heine-University of Duesseldorf, Department of Radiotherapy and Radiation Oncology, Duesseldorf (Germany)

    2014-04-15

    Recently two retrospective cohort studies report efficacy of bevacizumab in patients with recurrent atypical and anaplastic meningioma. Another successful therapeutic option of bevacizumab seems to be treatment of cerebral radiation necrosis. However, the antiangiogenic effects in MRI diffusion and perfusion in meningiomas have not been previously described in detail. The objective of this research was to evaluate the clinical and MR imaging effects of bevacizumab in a malignant meningioma patient harboring additional cerebral radiation necrosis. We report the case of an 80-year-old woman who underwent bevacizumab therapy (5 mg/kg every 2 weeks for 2 months) for treatment of a symptomatic radiation necrosis in malignant meningiomatosis of World Health Organization (WHO) grade III. The patient was closely monitored with MRI including diffusion and perfusion studies. Upon bevacizumab therapy, the clinical situation was well stabilized over a period of 4 months until the patient unfortunately died due to pneumonia/septicemia probably unrelated to bevacizumab therapy. Consecutive MRI demonstrated 4 important aspects: (1) considerable decrease of the contrast medium (CM)-enhanced radiation necrosis, (2) mixed response with respect to the meningiomatosis with stable and predominantly growing tumor lesions, (3) a new diffusion-weighted imaging (DWI) lesion in a CM-enhanced tumor as described in gliomas, which we did not interpret as a response to bevacizumab therapy, and (4) new thrombembolic infarcts, which are a known side-effect of bevacizumab treatment. Bevacizumab is effective in the treatment of radiation necrosis. We could not confirm the potential antitumor effect of bevacizumab in this patient. However, we could describe several new radiographic effects of bevacizumab therapy in malignant meningioma. (orig.) [German] In zwei aktuellen retrospektiven Kohortenstudien konnte eine Wirksamkeit von Bevacizumab bei Patienten mit rezidivierenden atypischen und

  20. Dynamic contrast-enhanced quantitative perfusion measurement of the brain using T-1-weighted MRI at 3T

    DEFF Research Database (Denmark)

    Larsson, H.B.W.; Hansen, A.E.; Berg, H.K.

    2008-01-01

    Purpose: To develop a method for the measurement of brain perfusion based on dynamic contrast-enhanced T-1-weighted MR imaging. Materials and Methods: Dynamic imaging of the first pass of a bolus of a paramagnetic contrast agent was performed using a 3T whole-body magnet and a T-1-weighted fast...... field echo sequence. The input function was obtained from the internal carotid artery. An initial T-1 measurement was performed in order to convert the MR signal to concentration of the contrast agent. Pixelwise and region of interest (ROI)based calculation of cerebral perfusion (CBF) was performed...... inside the infarct core was, 9 mL/100g/min in one of the stroke patients. The other stroke patient had postischemic hyperperfusion and CBF was 140 mL/100g/min. Conclusion: Absolute values of brain perfusion can be obtained using dynamic contrast-enhanced MRI. These values correspond,to expected values...

  1. MRI-based assessment of liver perfusion and hepatocyte injury in the murine model of acute hepatitis.

    Science.gov (United States)

    Byk, Katarzyna; Jasinski, Krzysztof; Bartel, Zaneta; Jasztal, Agnieszka; Sitek, Barbara; Tomanek, Boguslaw; Chlopicki, Stefan; Skorka, Tomasz

    2016-12-01

    To assess alterations in perfusion and liver function in the concanavalin A (ConA)-induced mouse model of acute liver failure (ALF) using two magnetic resonance imaging (MRI)-based methods: dynamic contrast-enhanced MRI (DCE-MRI) with Gd-EOB-DTPA contrast agent and arterial spin labelling (ASL). BALB/c mice were studied using a 9.4 T MRI system. The IntraGateFLASH TM and FAIR-EPI pulse sequences were used for optimum mouse abdomen imaging. The average perfusion values for the liver of the control and ConA group were equal to 245 ± 20 and 200 ± 32 ml/min/100 g (p = 0.008, respectively). DCE-MRI showed that the time to the peak of the image enhancement was 6.14 ± 1.07 min and 9.72 ± 1.69 min in the control and ConA group (p < 0.001, respectively), while the rate of the contrast wash-out in the control and ConA group was 0.037 ± 0.008 and 0.021 ± 0.008 min -1 (p = 0.004, respectively). These results were consistent with hepatocyte injury in the ConA-treated mice as confirmed by histopathological staining. Both the ASL and DCE-MRI techniques represent a reliable methodology to assess alterations in liver perfusion and hepatocyte integrity in murine hepatitis.

  2. The association between neurological deficit in acute ischemic stroke and mean transit time. Comparison of four different perfusion MRI algorithms

    International Nuclear Information System (INIS)

    Schellinger, Peter D.; Latour, Lawrence L.; Chalela, Julio A.; Warach, Steven; Wu, Chen-Sen

    2006-01-01

    The purpose of our study was to identify the perfusion MRI (pMRI) algorithm which yields a volume of hypoperfused tissue that best correlates with the acute clinical deficit as quantified by the NIH Stroke Scale (NIHSS) and therefore reflects critically hypoperfused tissue. A group of 20 patients with a first acute stroke and stroke MRI within 24 h of symptom onset were retrospectively analyzed. Perfusion maps were derived using four different algorithms to estimate relative mean transit time (rMTT): (1) cerebral blood flow (CBF) arterial input function (AIF)/singular voxel decomposition (SVD); (2) area peak; (3) time to peak (TTP); and (4) first moment method. Lesion volumes based on five different MTT thresholds relative to contralateral brain were compared with each other and correlated with NIHSS score. The first moment method had the highest correlation with NIHSS (r=0.79, P<0.001) followed by the AIF/SVD method, both of which did not differ significantly from each other with regard to lesion volumes. TTP and area peak derived both volumes, which correlated poorly or only moderately with NIHSS scores. Data from our pilot study suggest that the first moment and the AIF/SVD method have advantages over the other algorithms in identifying the pMRI lesion volume that best reflects clinical severity. At present there seems to be no need for extensive postprocessing and arbitrarily defined delay thresholds in pMRI as the simple qualitative approach with a first moment algorithm is equally accurate. Larger sample sizes which allow comparison between imaging and clinical outcomes are needed to refine the choice of best perfusion parameter in pMRI. (orig.)

  3. Comparison of stress-rest and rest-stress one day myocardial perfusion scintigraphies in detecting coronary artery diseases

    International Nuclear Information System (INIS)

    Bom, Hee Seung; Min, Jung Jun; Song, Ho Cheon; Kim, Ji Yeul

    1997-01-01

    It has been shown that both rest and stress myocardial perfusion imaging with technetium agents can be performed on the same day using two different doses injected within few hours. The purpose of this study was to compare the two protocols (stress-rest and rest-stress) in detecting coronary artery diseases. One hundred and sixty patients (101 males, 59 females, mean age 57±9 years) and 120 patients (79 males, 41 females, mean age 59±10 years) underwent stress-rest myocardial perfusion SPECT and rest-stress myocardial perfusion SPECT, respectively. All of them underwent both myocardial perfusion SPECT and coronary angiography within 1 month. A coronary stenosis was considered significant when it compromised the luminal diameter by ≥50%. The chi square test was used to compare differences in sensitivity, specificity and accuracy between the two groups. The overall sensitivity, specificity and accuracy of stress-rest protocol were 99%, 35% and 68%, respectively. Those of rest-stress protocol were 96%, 47% and 78%, respectively. There was no difference between the two protocols in identifying individual diseased coronary artery branches. Therefore, one day stress-rest and rest-stress myocardial SPECT using 99m Tc agents were comparable and were very sensitive tests in detecting coronary artery diseases

  4. Evaluation of femoral perfusion in a rabbit model of steroid-induced osteonecrosis by dynamic contrast-enhanced MRI with a high magnetic field MRI system.

    Science.gov (United States)

    Hayashi, Shigeki; Fujioka, Mikihiro; Ikoma, Kazuya; Saito, Masazumi; Ueshima, Keiichiro; Ishida, Masashi; Kuribayashi, Masaaki; Ikegami, Akira; Mazda, Osam; Kubo, Toshikazu

    2015-04-01

    To evaluate perfusion during the early phase after steroid administration in vivo using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) with a high magnetic field MRI system. The main pathogenesis of steroid-induced osteonecrosis is considered to be ischemia. A single dose of methylprednisolone (MPSL) was injected into nine rabbits. DCE-MRI was performed for these rabbits before MPSL administration and 1, 5, 10, and 14 days after administration. Time-signal intensity curves were created for each femur based on the signal intensity to evaluate perfusion. Enhancement ratio (ER), initial slope (IS), and area under the curve (AUC) were calculated and the value before MPSL administration and the minimal value after administration were compared statistically. ER, IS, and AUC values after MPSL administration significantly decreased (P < 0.05, P < 0.01, and P < 0.01, respectively). All of them decreased by the 5th day in 56% of the femora and by the 14th day in 83%, and some femora even showed a decrease from the 1st day. In this study, decreased perfusion in the femora after steroid administration was proven. Additionally, we could show that it occurred from the early days after steroid administration. © 2014 Wiley Periodicals, Inc.

  5. Diffusion- and Perfusion-weighted MRI Studies Just Before and After Removal of Hypertensive Putaminal Hematoma: Case Report

    OpenAIRE

    木下, 良正; 安河内, 秀興; 原田, 篤邦; 津留, 英智; 奥寺, 利男; 横田, 晃; Yoshimasa, KINOSHITA; Hideoki, YASUKOUCHI; Atsukuni, HARADA; Eichi, TSURU; Toshio, OKUDERA; Akira, YOKOTA; 宗像水光会総合病院 脳神経外科; 宗像水光会総合病院 脳神経外科; 宗像水光会総合病院 脳神経外科

    2007-01-01

    It has been suspected that a zone of perihematomal ischemia analogous to an ischemic penumbra exists in patients with subacute putaminal hemorrhage who showed transient neurological improvement with hyperbaric oxygenation therapy (HBO). A 54-year-old woman, who suffered from left putaminal hemorrhage, was examined for regional hemodynamics in the perihematomal region just before and just after the removal of putaminal hematoma in the subacute period by diffusion and perfusion MRI. The pyramid...

  6. Comparison of brain perfusion SPECT and MRI findings in children with neuronal ceroid-lipofuscinosis and in their families

    International Nuclear Information System (INIS)

    Sayit, E.; Yorulmaz, I; Gumuser, F.G.; Dirik, E.; Bekis, R.; Kaya, G.; Durak, H.

    2002-01-01

    Neuronal ceroid-lipofuscinoses (NCL) are among the progressive encephalopathies of childhood that are inherited in an autosomal recessive manner. In this study we specifically aimed to investigate any white-matter changes in the carriers (parents) and the healthy siblings of individuals with neuronal ceroid lipofuscinosis disease and whether we may be able to predict the occurrence of any neurological symptoms in healthy children in the future thus enabling early management. Since the NCLs are genetically determined diseases, we investigated fifteen individuals in three families that had diseased children of the juvenile type, with brain perfusion SPECT and MRI. Brain perfusion SPECT was performed after administering 222-555 MBq (6-15 mCi) Tc-99m hexamethyl-propylene amine oxime (HMPAO) intravenously in a dimmed and quiet room. Imaging was performed at least one hour after injection, with a three headed gamma camera equipped with high resolution collimators. A Metz filter (FWHM: 11 mm) was used for processing. Cranial MRI was performed with an imager operating at 1.5 Tesla. Spin-echo T1- and T2-weighted and FLAIR slices were obtained for each individual. In all of the five diseased children we observed pathologic findings both on MRI and Tc-99m HMPAO SPECT. The findings on MRI were mainly features of cerebral and cerebellar atrophy and the observations on Tc-99m HMPAO SPECT were regional perfusion abnormalities. We observed some structural abnormalities on MRI in four of the parents and two of the four healthy siblings. We also noted perfusion abnormalities on Tc-99m HMPAO SPECT in two of the parents and two of the healthy siblings. Because the disease is inherited in an autosomal recessive manner, the parents and the healthy siblings were not supposed to exhibit any demonstrable brain lesions, but the brain perfusion SPECT and MRI examinations clearly revealed multiple lesions in some of the parents and healthy siblings. Detailed neurological examinations of these

  7. Quantifying fluctuations of resting state networks using arterial spin labeling perfusion MRI.

    Science.gov (United States)

    Dai, Weiying; Varma, Gopal; Scheidegger, Rachel; Alsop, David C

    2016-03-01

    Blood oxygen level dependent (BOLD) functional magnetic resonance imaging (fMRI) has been widely used to investigate spontaneous low-frequency signal fluctuations across brain resting state networks. However, BOLD only provides relative measures of signal fluctuations. Arterial Spin Labeling (ASL) MRI holds great potential for quantitative measurements of resting state network fluctuations. This study systematically quantified signal fluctuations of the large-scale resting state networks using ASL data from 20 healthy volunteers by separating them from global signal fluctuations and fluctuations caused by residual noise. Global ASL signal fluctuation was 7.59% ± 1.47% relative to the ASL baseline perfusion. Fluctuations of seven detected resting state networks vary from 2.96% ± 0.93% to 6.71% ± 2.35%. Fluctuations of networks and residual noise were 6.05% ± 1.18% and 6.78% ± 1.16% using 4-mm resolution ASL data applied with Gaussian smoothing kernel of 6mm. However, network fluctuations were reduced by 7.77% ± 1.56% while residual noise fluctuation was markedly reduced by 39.75% ± 2.90% when smoothing kernel of 12 mm was applied to the ASL data. Therefore, global and network fluctuations are the dominant structured noise sources in ASL data. Quantitative measurements of resting state networks may enable improved noise reduction and provide insights into the function of healthy and diseased brain. © The Author(s) 2015.

  8. Dynamic Contrast-Enhanced Perfusion MRI of High Grade Brain Gliomas Obtained with Arterial or Venous Waveform Input Function.

    Science.gov (United States)

    Filice, Silvano; Crisi, Girolamo

    2016-01-01

    The aim of this study was to evaluate the differences in dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) perfusion estimates of high-grade brain gliomas (HGG) due to the use of an input function (IF) obtained respectively from arterial (AIF) and venous (VIF) approaches by two different commercially available software applications. This prospective study includes 20 patients with pathologically confirmed diagnosis of high-grade gliomas. The data source was processed by using two DCE dedicated commercial packages, both based on the extended Toft model, but the first customized to obtain input function from arterial measurement and the second from sagittal sinus sampling. The quantitative parametric perfusion maps estimated from the two software packages were compared by means of a region of interest (ROI) analysis. The resulting input functions from venous and arterial data were also compared. No significant difference has been found between the perfusion parameters obtained with the two different software packages (P-value < .05). The comparison of the VIFs and AIFs obtained by the two packages showed no statistical differences. Direct comparison of DCE-MRI measurements with IF generated by means of arterial or venous waveform led to no statistical difference in quantitative metrics for evaluating HGG. However, additional research involving DCE-MRI acquisition protocols and post-processing would be beneficial to further substantiate the effectiveness of venous approach as the IF method compared with arterial-based IF measurement. Copyright © 2015 by the American Society of Neuroimaging.

  9. Stress perfusion magnetic resonance imaging to detect coronary artery lesions in children.

    Science.gov (United States)

    Vijarnsorn, Chodchanok; Noga, Michelle; Schantz, Daryl; Pepelassis, Dion; Tham, Edythe B

    2017-05-01

    Stress perfusion cardiovascular magnetic resonance (CMR) is used widely in adult ischemic heart disease, but data in children is limited. We sought to evaluate feasibility, accuracy and prognostic value of stress CMR in children with suspected coronary artery disease (CAD). Stress CMR was reviewed from two pediatric centers over 5 years using a standard pharmacologic protocol. Wall motion abnormalities, perfusion deficits and late enhancement were correlated with coronary angiogram (CAG) when available, and clinical status at 1 year follow-up for major adverse cardiovascular events (MACE; coronary revascularization, non-fatal myocardial infarction and death due to CAD) was recorded. Sixty-four stress perfusion CMR studies in 48 children (10.9 ± 4.8 years) using adenosine; 59 (92%) and dipyridamole; 5 (8%), were reviewed. Indications were Kawasaki disease (39%), post arterial switch operation (12.5%), post heart transplantation (12.5%), post anomalous coronary artery repair (11%), chest pain (11%), suspected myocarditis or CAD (3%), post coronary revascularization (3%), and others (8%). Twenty-six studies were performed under sedation. Of all studies performed, 66% showed no evidence of ischemia or infarction, 28% had perfusion deficits and 6% had late gadolinium enhancement (LGE) without perfusion deficit. Compared to CAG, the positive predictive value (PPV) of stress CMR was 80% with negative predictive value (NPV) of 88%. At 1 year clinical follow-up, the PPV and NPV of stress CMR to predict MACE were 78 and 98%. Stress-perfusion CMR, in combination with LGE and wall motion-analysis is a feasible and an accurate method of diagnosing CAD in children. In difficult cases, it also helps guide clinical intervention by complementing conventional CAG with functional information.

  10. MRI findings in multifetal pregnancies complicated by twin reversed arterial perfusion sequence (TRAP)

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Carolina V.A.; Kline-Fath, Beth M.; Linam, Leann E.; Calvo Garcia, Maria A.; Rubio, Eva I. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Lim, Foong-Yen [Cincinnati Children' s Hospital Medical Center, Division of Pediatric Surgery, Cincinnati, OH (United States)

    2011-06-15

    Twin reversed arterial perfusion sequence (TRAP) is a rare complication in multifetal monochorionic pregnancies in which a normal ''pump'' twin provides circulation to an abnormal acardiac co-twin, resulting in high-output cardiac dysfunction in the pump twin. To define fetal MRI findings of TRAP sequence. Fetal MR images were retrospectively reviewed in 35 pregnancies complicated by TRAP sequence. Abnormalities of the pump twin, acardiac twin, umbilical cord, placenta and amniotic fluid were reviewed. Acardiac twins were classified as: acephalus (51%), anceps (40%), amorphus (9%), acormus (0%). Common findings in acardiac twins include subcutaneous edema (77%), absent cardiac structures (86%), absent or abnormal thoracic cavity (100%), abnormal abdominal organs (100%), superior limbs absent (46%) or abnormal (51%), and inferior limbs present but abnormal (83%). There were pump twin findings of cardiac dysfunction in 43% and intracranial ischemic changes in 3%. Umbilical cord anomalies were present in 97%. Acardiac twins present with a predictable pattern of malformation with poorly developed superior structures, more normally formed inferior structures and absent or rudimentary heart. Although usually absent, abnormal heart structures can be seen and do not exclude TRAP sequence. Pump twins are commonly normal with exception of findings of cardiac dysfunction and possible brain ischemia. (orig.)

  11. Regional MRI Perfusion Measures Predict Motor/Executive Function in Patients with Clinically Isolated Syndrome

    Directory of Open Access Journals (Sweden)

    Efrosini Z. Papadaki

    2014-01-01

    Full Text Available Background. Patients with clinically isolated syndrome (CIS demonstrate brain hemodynamic changes and also suffer from difficulties in processing speed, memory, and executive functions. Objective. To explore whether brain hemodynamic disturbances in CIS patients correlate with executive functions. Methods. Thirty CIS patients and forty-three healthy subjects, matched for age, gender, education level, and FSIQ, were administered tests of visuomotor learning and set shifting ability. Cerebral blood volume (CBV, cerebral blood flow (CBF, and mean transit time (MTT values were estimated in normal-appearing white matter (NAWM and normal-appearing deep gray Matter (NADGM structures, using a perfusion MRI technique. Results. CIS patients showed significantly elevated reaction time (RT on both tasks, while their CBV and MTT values were globally increased, probably due to inflammatory vasodilation. Significantly, positive correlation coefficients were found between error rates on the inhibition condition of the visuomotor learning task and CBV values in occipital, periventricular NAWM and both thalami. On the set shifting condition of the respective task significant, positive associations were found between error rates and CBV values in the semioval center and periventricular NAWM bilaterally. Conclusion. Impaired executive function in CIS patients correlated positively with elevated regional CBV values thought to reflect inflammatory processes.

  12. Perfusion kinetics in human brain tumor with DCE-MRI derived model and CFD analysis.

    Science.gov (United States)

    Bhandari, A; Bansal, A; Singh, A; Sinha, N

    2017-07-05

    Cancer is one of the leading causes of death all over the world. Among the strategies that are used for cancer treatment, the effectiveness of chemotherapy is often hindered by factors such as irregular and non-uniform uptake of drugs inside tumor. Thus, accurate prediction of drug transport and deposition inside tumor is crucial for increasing the effectiveness of chemotherapeutic treatment. In this study, a computational model of human brain tumor is developed that incorporates dynamic contrast enhanced-magnetic resonance imaging (DCE-MRI) data into a voxelized porous media model. The model takes into account realistic transport and perfusion kinetics parameters together with realistic heterogeneous tumor vasculature and accurate arterial input function (AIF), which makes it patient specific. The computational results for interstitial fluid pressure (IFP), interstitial fluid velocity (IFV) and tracer concentration show good agreement with the experimental results. The computational model can be extended further for predicting the deposition of chemotherapeutic drugs in tumor environment as well as selection of the best chemotherapeutic drug for a specific patient. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. The role of pharmacological stress Tc-99m sestamibi myocardial perfusion imaging in an Australian population

    International Nuclear Information System (INIS)

    Howarth, D.M.; Booker, J.A.; Tan, T.S.K.; Bellamy, G.R.; Hardy, D.B.; Howarth, G.C.

    2003-01-01

    This observational study was performed in order to assess the exercise-related incremental diagnostic accuracy of Tc-99m sestamibi myocardial perfusion imaging (MPI) in a hospital-based Australian population, and to assess the relative roles of exercise and pharmacological stress in myocardial perfusion imaging (MPI). Two hundred and eight adult patients who had both Tc-99m sestamibi myocardial perfusion imaging and coronary angiography within a median time of 16 weeks were studied. The diagnostic end-point was coronary artery lesions of ≥50% and >70% stenosis detected on angiography. Using receiver operating characteristic curve analysis, the overall diagnostic accuracy was calculated, as well as the comparative accuracies in patients who undertook various levels of exercise stress testing (n=130) and those who received pharmacological (dipyridamole) stress testing (n=78). The overall respective diagnostic accuracy of Tc-99m sestamibi MPI for the diagnosis of coronary artery disease (>70% stenosis) was 81% and 76% when using the diagnostic criterion of ≥50% stenosis. On direct comparison of perfusion defects with angiographic stenoses, the respective sensitivity and specificity for the detection of >70% stenosis in each coronary artery territory was 73% and 79%. Pharmacological MPI showed a significantly greater sensitivity for the detection of localised stenoses compared to the overall group who had exercise MPI performed. Consequently, exercise stress MPI showed significantly more false negative lesions compared to dipyridamole stress imaging (p<0.003). However, a large proportion of patients were unable to perform to adequate exercise levels in this patient sample. We conclude that Tc-99m sestamibi myocardial perfusion imaging is an accurate non-invasive test for the diagnosis of coronary artery disease. Where any doubt exists as to the patient's ability to achieve exercise levels at or above 85% of the predicted value for age and gender, pharmacological

  14. Effect of steroid on brain tumors and surround edemas : observation with regional cerebral blood volume (rCBV) maps of perfusion MRI

    International Nuclear Information System (INIS)

    Choi, Ju Youl; Sun, Joo Sung; Kim, Sun Yong; Kim, Ji Hyung; Suh, Jung Ho; Cho, Kyung Gi; Kim, Jang Sung

    2000-01-01

    To observe the hemodynamic change in brain tumors and peritumoral edemas after steroid treatment, and then investigate the clinical usefulness of perfusion MRI. We acquired conventional and perfusion MR images in 15 patients with various intracranial tumors (4 glioblastoma multiformes, 4 meningiomas, 3 metastatic tumors, 1 anaplastic ependymoma, 1 anaplastic astrocytoma, 1 hemangioblastoma, and 1 pilocytic astrocytoma). For perfusion MR imaging, a 1.5T unit employing the gradient-echo EPI technique was used, and further perfusion MR images were obtained 2-10 days after intravenous steroid therapy. After processing of the raw data, regional cerebral blood volume (rCBV) maps were reconstructed. The maps were visually evaluated by comparing relative perfusion in brain tumors and peritumoral edemas with that in contralateral white matter. Objective evaluations were performed by comparing the perfusion ratios of brain tumors and peritumoral edemas. Visual evaluations of rCBV maps, showed that in most brain tumors (67%, 10/15), perfusion was high before steroid treatment and showed in (80%, 12/15) decreased afterwards. Objective evaluation, showed that in all brain tumors, perfusion decreased. Visual evaluation of perfusion change in peritumoral edemas revealed change in only one case, but objective evaluation indicated that perfusion decreased significantly in all seven cases. rCBV maps acquired by perfusion MR imaging can provide hemodynamic information about brain tumors and peritumoral edemas. Such maps could prove helpful in the preoperative planning of brain tumor surgery and the monitoring of steroid effects during conservative treatment. (author)

  15. Myocardial stress perfusion magnetic resonance: initial experience in a pediatric and young adult population using regadenoson

    International Nuclear Information System (INIS)

    Noel, Cory V.; Krishnamurthy, Ramkumar; Krishnamurthy, Rajesh; Moffett, Brady

    2017-01-01

    Dipyridamole and adenosine are traditional pharmacological stressors for myocardial perfusion. Regadenoson, a selective adenosine A2A agonist, has a lower side effect profile with lower incidence of bronchospasm and bradycardia. There is a growing need for myocardial perfusion assessment within pediatrics. There is no report on the utility of regadenoson as a stress agent in children. To observe the safety and feasibility of regadenoson as a pharmacologic stressor for perfusion cardiac MR in a pilot cohort of pediatric patients weighing more than 40 kg who have congenital heart disease and pediatric acquired heart disease. We reviewed our initial experience with regadenoson stress cardiac MR in 31 pediatric patients 15.8 ± 1.7 years (range 12-22 years) with congenital heart disease and acquired heart disease. Mean patient weight was 60 ± 15 kg (range of 40-93 kg). All patients underwent cardiac MR because of concern for ischemia. The cohort included a heterogeneous group of patients at a pediatric institution with potential risk for ischemia. Subjects' heart rate and blood pressure were monitored and pharmacologic stress was induced by injection of 400 mcg of regadenoson. We evaluated their hemodynamic response and adverse effects using changes in vital signs and onset of symptoms. A pediatric cardiologist and radiologist qualitatively assessed myocardial perfusion and viability images. One child was unable to complete the stress perfusion portion of the examination, but did complete the remaining portion of the CMR. Resting heart rate was 72 ± 14 beats per minute (bpm) and rose to peak of 124 ± 17 bpm (95 ± 50% increase, P < 0.005) with regadenoson. Image quality was considered good or diagnostic in all cases. Three patients had irreversible perfusion defects. Four patients had reversible perfusion defects. Nine of the patients underwent cardiac catheterization with angiography and the findings showed excellent agreement. Regadenoson might be a safe and

  16. Myocardial stress perfusion magnetic resonance: initial experience in a pediatric and young adult population using regadenoson

    Energy Technology Data Exchange (ETDEWEB)

    Noel, Cory V. [Baylor College of Medicine, Department of Pediatric Cardiology, Houston, TX (United States); Texas Children' s Hospital, Department of Pediatric Cardiology, Houston, TX (United States); Krishnamurthy, Ramkumar; Krishnamurthy, Rajesh [Texas Children' s Hospital, Department of Radiology, Houston, TX (United States); Moffett, Brady [Texas Children' s Hospital, Department of Pharmacology, Houston, TX (United States)

    2017-03-15

    Dipyridamole and adenosine are traditional pharmacological stressors for myocardial perfusion. Regadenoson, a selective adenosine A2A agonist, has a lower side effect profile with lower incidence of bronchospasm and bradycardia. There is a growing need for myocardial perfusion assessment within pediatrics. There is no report on the utility of regadenoson as a stress agent in children. To observe the safety and feasibility of regadenoson as a pharmacologic stressor for perfusion cardiac MR in a pilot cohort of pediatric patients weighing more than 40 kg who have congenital heart disease and pediatric acquired heart disease. We reviewed our initial experience with regadenoson stress cardiac MR in 31 pediatric patients 15.8 ± 1.7 years (range 12-22 years) with congenital heart disease and acquired heart disease. Mean patient weight was 60 ± 15 kg (range of 40-93 kg). All patients underwent cardiac MR because of concern for ischemia. The cohort included a heterogeneous group of patients at a pediatric institution with potential risk for ischemia. Subjects' heart rate and blood pressure were monitored and pharmacologic stress was induced by injection of 400 mcg of regadenoson. We evaluated their hemodynamic response and adverse effects using changes in vital signs and onset of symptoms. A pediatric cardiologist and radiologist qualitatively assessed myocardial perfusion and viability images. One child was unable to complete the stress perfusion portion of the examination, but did complete the remaining portion of the CMR. Resting heart rate was 72 ± 14 beats per minute (bpm) and rose to peak of 124 ± 17 bpm (95 ± 50% increase, P < 0.005) with regadenoson. Image quality was considered good or diagnostic in all cases. Three patients had irreversible perfusion defects. Four patients had reversible perfusion defects. Nine of the patients underwent cardiac catheterization with angiography and the findings showed excellent agreement. Regadenoson might be a safe and

  17. Value of conventional, and diffusion- and perfusion weighted MRI in the management of patients with unclear cerebral pathology, admitted to the intensive care unit

    International Nuclear Information System (INIS)

    Sundgren, P.C.; Reinstrup, P.; Romner, B.; Holtaas, S.; Maly, P.

    2002-01-01

    The aim of our retrospective study was to determine the extent to which diffusion- and perfusion- weighted MRI combined with conventional MRI could be helpful in the evaluation of intensive care unit (ICU) patients who have unknown or unclear cerebral pathology underlying a serious clinical condition. Twenty-one ICU patients with disparity between the findings on brain CT scan and their clinical status were studied. All patients underwent conventional MR and diffusion-weighted imaging and 14 also had MR perfusion studies. Abnormalities were present on diffusion-weighted imaging of 17 of the 21 patients and on perfusion-weighted studies of 7 of 14 patients. The MRI results changed the preliminary/working diagnosis in six patients. In eight other patients, MRI revealed additional pathology that had not been suspected clinically, and/or characterized more closely findings that had already been detected by CT or suspected clinically. MRI showed abnormalities in four of the five patients who had normal CT. MRI findings suggested a negative clinical outcome in all nine patients who subsequently died. MRI findings also suggested positive long-term outcome in five of nine patients who improved significantly as based on Glasgow and extended Glasgow outcome scales. In the three unconscious patients who had normal diffusion- and perfusion-weighted imaging the clinical outcome was good. This study suggests that MRI in seriously ill ICU patients with unclear cerebral pathology can provide information that changes, characterizes, or supports diagnoses and/or prognoses and therefore facilitates further management. (orig.)

  18. Prognostic value of high-dose dobutamine stress magnetic resonance imaging in 1,493 consecutive patients: assessment of myocardial wall motion and perfusion.

    Science.gov (United States)

    Korosoglou, Grigorios; Elhmidi, Yacine; Steen, Henning; Schellberg, Dieter; Riedle, Nina; Ahrens, Johannes; Lehrke, Stephanie; Merten, Constanze; Lossnitzer, Dirk; Radeleff, Jannis; Zugck, Christian; Giannitsis, Evangelos; Katus, Hugo A

    2010-10-05

    This study sought to determine the prognostic value of wall motion and perfusion assessment during high-dose dobutamine stress (DS) cardiac magnetic resonance imaging (MRI) in a large patient cohort. DS-MRI offers the possibility to integrate myocardial perfusion and wall motion analysis in a single examination for the detection of coronary artery disease (CAD). A total of 1,493 consecutive patients with suspected or known CAD underwent DS-MRI, using a standard protocol in a 1.5-T magnetic resonance scanner. Wall motion and perfusion were assessed at baseline and during stress, and outcome data including cardiac death, nonfatal myocardial infarction ("hard events"), and "late" revascularization performed >90 days after the MR scans were collected during a 2 ± 1 year follow-up period. Fifty-three hard events, including 14 cardiac deaths and 39 nonfatal infarctions, occurred during the follow-up period, whereas 85 patients underwent "late" revascularization. Using multivariable regression analysis, an abnormal result for wall motion or perfusion during stress yielded the strongest independent prognostic value for both hard events and late revascularization, clearly surpassing that of clinical and baseline magnetic resonance parameters (for wall motion: adjusted hazard ratio [HR] of 5.9 [95% confidence interval (CI): 2.5 to 13.6] for hard events and of 3.1 [95% CI: 1.7 to 5.6] for late revascularization, and for perfusion: adjusted HR of 5.4 [95% CI: 2.3 to 12.9] for hard events and of 6.2 [95% CI: 3.3 to 11.3] for late revascularization, p < 0.001 for all). DS-MRI can accurately identify patients who are at increased risk for cardiac death and myocardial infarction, separating them from those with normal findings, who have very low risk for future cardiac events. (Prognostic Value of High Dose Dobutamine Stress Magnetic Resonance Imaging; NCT00837005). Copyright © 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Specific perfusion pattern in stress 201Tl myocardial scintigraphy of left main coronary artery disease

    International Nuclear Information System (INIS)

    Wakasugi, Shigetoshi; Shibata, Nobuhiko; Kobayashi, Tohru; Fudemoto, Yoshiyuki; Hasegawa, Yoshihisa; Nakano, Shunichi

    1986-01-01

    The usefulness of stress 201 Tl myocardial scintigraphy for identifying left main coronary artery disease was evaluated with data from 23 patients with 50% or more narrowing of the left main coronary artery and 56 patients with 75% or more narrowing of the major coronary arteries but without left main coronary artery involvement (no left main coronary artery disease). Quantitative evaluation of stress perfusion scintigrams in all five patients with narrowing of the left main coronary artery of 90% or more showed a characteristic perfusion pattern (left main pattern) of extensive homogeneous defect over the whole anterolateral segment and simultaneous defects in all radii of the high anteroseptal and high posterolateral segments. On the other hand, such a perfusion pattern was noted in only 1 of 18 patients with less than 90% stenosis of the left main coronary artery and in only 1 of 56 patients with no left coronary artery disease. (orig.)

  20. A novel method to assess pial collateralization from stroke perfusion MRI: subdividing T{sub max} into anatomical compartments

    Energy Technology Data Exchange (ETDEWEB)

    Potreck, Arne; Seker, Fatih; Hoffmann, Angelika; Pfaff, Johannes; Bendszus, Martin; Heiland, Sabine; Pham, Mirko [Heidelberg University Hospital, Department of Neuroradiology, Heidelberg (Germany); Nagel, Simon [Heidelberg University Hospital, Department of Neurology, Heidelberg (Germany)

    2017-02-15

    To develop and validate a quantitative and observer-independent method to evaluate pial collateral circulation by DSC-perfusion MRI and test whether this novel method delivers diagnostic information which is redundant to or independent from conventional penumbra imaging by the mismatch approach. We retrospectively identified 47 patients with M1 occlusion who underwent MR diffusion/perfusion imaging and mechanical thrombectomy at our facility. By automated registration and segmentation, T{sub max} delays were attributed specifically to the pial, cortical and parenchymal compartments. The resulting pial volumes at delay were defined as the pial T{sub max} map-assessed collateral score (TMACS) and correlated with gold standard digital subtraction angiography (DSA). Mismatch ratio was assessed by conventional penumbra defining MRI criteria. Strong correlation was found between TMACS and angiographically assessed collateral score (Pearson ρ = -0.74, p < 0.001). In multiple logistic regression, both good collaterals according to TMACS [OR 4.3 (1.1-19, p = 0.04)] and mismatch ratio ≥ 3.5 [OR 12.3 (1.88-249, p = 0.03)] were independent predictors of favourable clinical outcome. Perfusion delay in the pial compartment, as evaluated by TMACS, closely reflects the extent of pial collaterals in gold-standard DSA. TMACS and mismatch ratio were found to be complementary predictors of a favourable clinical outcome, each adding independent predictive information. (orig.)

  1. Focal time-to-peak changes on perfusion MRI in children with Moyamoya disease: correlation with conventional angiography

    International Nuclear Information System (INIS)

    Choi, Hyun Seok; Kim, Dong-Seok; Shim, Kyu-Won; Kim, Jinna; Kim, Eun Soo; Lee, Seung-Koo

    2011-01-01

    Background: Moyamoya disease is a chronic progressive steno-occlusion of the distal internal carotid arteries with unknown etiology. As the classical presentation of childhood Moyamoya disease is ischemic stroke, cerebral hemodynamic evaluation is important for patient selection for surgery to prevent recurrent ischemic attacks. Perfusion MR imaging has been applied to evaluate cerebral hemodynamics. Purpose: To correlate the 'basal time-to-peak preservation sign', 'auto-synangiosis sign', and 'posterior involvement sign' on time-to-peak map of perfusion MRI with catheter angiography. Material and Methods: Thirty-four children (6.91 ± 3.08 years) with Moyamoya disease who underwent both perfusion-weighted MRI and catheter angiography were enrolled in this study. Given catheter angiography as a reference standard, basal time-to-peak preservation sign, auto-synangiosis sign, and posterior involvement sign were evaluated on time-to-peak maps. Results: The basal time-to-peak preservation sign was accurate for the diagnosis of childhood Moyamoya disease; both sensitivity and specificity were 100%. The auto-synangiosis sign showed lower sensitivity (65%), however, with an acceptable specificity (98%). The posterior involvement sign showed lower sensitivity (61%) but had an acceptable specificity (96%). Conclusion: The basal time-to-peak preservation sign may be a universal finding in childhood Moyamoya disease. The auto-synangiosis and posterior involvement sign may be useful in determining transdural collateral status and posterior circulation involvement in childhood Moyamoya disease

  2. Free-breathing cardiac MR stress perfusion with real-time slice tracking.

    Science.gov (United States)

    Basha, Tamer A; Roujol, Sébastien; Kissinger, Kraig V; Goddu, Beth; Berg, Sophie; Manning, Warren J; Nezafat, Reza

    2014-09-01

    To develop a free-breathing cardiac MR perfusion sequence with slice tracking for use after physical exercise. We propose to use a leading navigator, placed immediately before each 2D slice acquisition, for tracking the respiratory motion and updating the slice location in real-time. The proposed sequence was used to acquire CMR perfusion datasets in 12 healthy adult subjects and 8 patients. Images were compared with the conventional perfusion (i.e., without slice tracking) results from the same subjects. The location and geometry of the myocardium were quantitatively analyzed, and the perfusion signal curves were calculated from both sequences to show the efficacy of the proposed sequence. The proposed sequence was significantly better compared with the conventional perfusion sequence in terms of qualitative image scores. Changes in the myocardial location and geometry decreased by 50% in the slice tracking sequence. Furthermore, the proposed sequence had signal curves that are smoother and less noisy. The proposed sequence significantly reduces the effect of the respiratory motion on the image acquisition in both rest and stress perfusion scans. Copyright © 2013 Wiley Periodicals, Inc.

  3. Identification of a candidate biomarker from perfusion MRI to anticipate glioblastoma progression after chemoradiation

    Energy Technology Data Exchange (ETDEWEB)

    Khalifa, J. [INSERM UMR 1214, TONIC (TOulouse NeuroImaging Centre), Toulouse (France); Institut Claudius Regaud/Institut Universitaire du Cancer de Toulouse - Oncopole, Department of Radiation Oncology, Toulouse (France); Tensaouti, F. [INSERM UMR 1214, TONIC (TOulouse NeuroImaging Centre), Toulouse (France); Chaltiel, L. [Institut Claudius Regaud/Institut Universitaire du Cancer de Toulouse - Oncopole, Department of Biostatistics, Toulouse (France); Lotterie, J.A. [INSERM UMR 1214, TONIC (TOulouse NeuroImaging Centre), Toulouse (France); CHU Rangueil, Department of Nuclear Medicine, Toulouse (France); Catalaa, I. [INSERM UMR 1214, TONIC (TOulouse NeuroImaging Centre), Toulouse (France); CHU Rangueil, Department of Radiology, Toulouse (France); Sunyach, M.P. [Centre Leon Berard, Department of Radiation Oncology, Lyon (France); Ibarrola, D. [CERMEP - Imagerie du Vivant, Lyon (France); Noel, G. [EA 3430, University of Strasbourg, Department of Radiation Oncology, Centre Paul Strauss, Strasbourg (France); Truc, G. [Centre Georges-Francois Leclerc, Department of Radiation Oncology, Dijon (France); Walker, P. [University of Burgundy, Laboratory of Electronics, Computer Science and Imaging (Le2I), UMR 6306 CNRS, Dijon (France); Magne, N. [Institut de cancerologie Lucien-Neuwirth, Department of Radiation Oncology, Saint-Priest-en-Jarez (France); Charissoux, M. [Department of Radiation Oncology, Institut du Cancer de Montpellier, Montpellier (France); Ken, S. [INSERM UMR 1214, TONIC (TOulouse NeuroImaging Centre), Toulouse (France); Institut Claudius Regaud/Institut Universitaire du Cancer de Toulouse - Oncopole, Department of Medical Physics, Toulouse (France); Peran, P. [INSERM UMR 1214, TONIC (TOulouse NeuroImaging Centre), Toulouse (France); Universite Toulouse III Paul Sabatier, UMR 1214, Toulouse (France); Berry, I. [INSERM UMR 1214, TONIC (TOulouse NeuroImaging Centre), Toulouse (France); CHU Rangueil, Department of Nuclear Medicine, Toulouse (France); Universite Toulouse III Paul Sabatier, UMR 1214, Toulouse (France); Moyal, E.C. [Institut Claudius Regaud/Institut Universitaire du Cancer de Toulouse - Oncopole, Department of Radiation Oncology, Toulouse (France); Universite Toulouse III Paul Sabatier, Toulouse (France); INSERM U1037, Centre de Recherches contre le Cancer de Toulouse, Toulouse (FR); Laprie, A. [INSERM UMR 1214, TONIC (TOulouse NeuroImaging Centre), Toulouse (FR); Institut Claudius Regaud/Institut Universitaire du Cancer de Toulouse - Oncopole, Department of Radiation Oncology, Toulouse (FR); Universite Toulouse III Paul Sabatier, Toulouse (FR)

    2016-11-15

    To identify relevant relative cerebral blood volume biomarkers from T2* dynamic-susceptibility contrast magnetic resonance imaging to anticipate glioblastoma progression after chemoradiation. Twenty-five patients from a prospective study with glioblastoma, primarily treated by chemoradiation, were included. According to the last follow-up MRI confirmed status, patients were divided into: relapse group (n = 13) and control group (n = 12). The time of last MR acquisition was t{sub end}; MR acquisitions performed at t{sub end-2M}, t{sub end-4M} and t{sub end-6M} (respectively 2, 4 and 6 months before t{sub end}) were analyzed to extract relevant variations among eleven perfusion biomarkers (B). These variations were assessed through R(B), as the absolute value of the ratio between ∇B from t{sub end-4M} to t{sub end-2M} and ∇B from t{sub end-6M} to t{sub end-4M}. The optimal cut-off for R(B) was determined using receiver-operating-characteristic curve analysis. The fraction of hypoperfused tumor volume (F{sub h}P{sub g}) was a relevant biomarker. A ratio R(F{sub h}P{sub g}) ≥ 0.61 would have been able to anticipate relapse at the next follow-up with a sensitivity/specificity/accuracy of 92.3 %/63.6 %/79.2 %. High R(F{sub h}Pg) (≥0.61) was associated with more relapse at t{sub end} compared to low R(F{sub h}Pg) (75 % vs 12.5 %, p = 0.008). Iterative analysis of F{sub h}P{sub g} from consecutive examinations could provide surrogate markers to predict progression at the next follow-up. (orig.)

  4. Prognostic value of combined CT angiography and myocardial perfusion imaging versus invasive coronary angiography and nuclear stress perfusion imaging in the prediction of major adverse cardiovascular events

    DEFF Research Database (Denmark)

    Chen, Marcus Y.; Rochitte, Carlos E.; Arbab-Zadeh, Armin

    2017-01-01

    Purpose: To compare the prognostic importance (time to major adverse cardiovascular event [MACE]) of combined computed tomography (CT) angiography and CT myocardial stress perfusion imaging with that of combined invasive coronary angiography (ICA) and stress single photon emission CT myocardial p...

  5. Clinical evaluation of lung rest/stress perfusion scintigraphy in patients with severe emphysema

    International Nuclear Information System (INIS)

    Hadjikostova, Hr.

    1998-01-01

    Volume lung reduction surgery (LVRS) improves lung function and physical tolerance for selected patients with severe pulmonary emphysema by making conditions for developing of the vital parenchyma so far compressed by the emphysema blisters. The aim of this study was to establish the comparative functional information obtained from REST/STRESS lung perfusion tomoscintigraphies for identification of non functional lung tissue. Eleven patients (8 males and 3 females at age 41-60) were examined by two lung perfusions SPECT scintigraphies after intravenous application of 222 MBq 99m Tc-MAA: 1. after 30 min. lying rest and 2. 48 hours later after 6 min. walk test. Comparing the two scintigraphies the following changes in perfusion performance have been established at STRESS examination: increased at six patients (significant at three and slight also at three) and decreased at two. There was no difference between REST and STRESS examinations at 3 patients. Comparative REST/STRESS lung perfusion scintigraphy is important method for screening severe pulmonary patients for LVRS. (author)

  6. Reversible changes in echo planar perfusion- and diffusion-weighted MRI in status epilepticus

    International Nuclear Information System (INIS)

    Flacke, S.; Keller, E.; Urbach, H.; Wuellner, U.; Hamzei, F.

    2000-01-01

    Perfusion imaging (PI) demonstrated increased perfusion and diffusion-weighted imaging (DWI) showed high signal limited to the left temporoparietal cortex in a 68-year-old man with nonconvulsive status epilepticus. The EEG showed a slow delta-wave focus. The patient recovered and PI, DWI and EEG changes completely resolved. (orig.)

  7. Reversible changes in echo planar perfusion- and diffusion-weighted MRI in status epilepticus

    Energy Technology Data Exchange (ETDEWEB)

    Flacke, S; Keller, E; Urbach, H [Dept. of Radiology, Univ. of Bonn (Germany); Wuellner, U; Hamzei, F [Dept. of Neurology, Univ. of Bonn (Germany)

    2000-02-01

    Perfusion imaging (PI) demonstrated increased perfusion and diffusion-weighted imaging (DWI) showed high signal limited to the left temporoparietal cortex in a 68-year-old man with nonconvulsive status epilepticus. The EEG showed a slow delta-wave focus. The patient recovered and PI, DWI and EEG changes completely resolved. (orig.)

  8. Prognostic value of preoperative dynamic contrast-enhanced MRI perfusion parameters for high-grade glioma patients

    Energy Technology Data Exchange (ETDEWEB)

    Ulyte, Agne [Vilnius University, Faculty of Medicine, Vilnius (Lithuania); Katsaros, Vasileios K. [General Anticancer and Oncological Hospital ' ' St. Savvas' ' , Department of Advanced Imaging Modalities - CT and MRI, Athens (Greece); University of Athens, Department of Neurosurgery, Evangelismos Hospital, Athens (Greece); Liouta, Evangelia; Stranjalis, Georgios [University of Athens, Department of Neurosurgery, Evangelismos Hospital, Athens (Greece); Boskos, Christos [University of Athens, Department of Neurosurgery, Evangelismos Hospital, Athens (Greece); General Anticancer and Oncological Hospital ' ' St. Savvas' ' , Department of Radiation Oncology, Athens (Greece); Papanikolaou, Nickolas [Champalimaud Foundation, Department of Radiology, Centre for the Unknown, Lisbon (Portugal); Usinskiene, Jurgita [National Cancer Institute, Vilnius (Lithuania); Affidea Lietuva, Vilnius (Lithuania); Bisdas, Sotirios [University College London Hospitals, Department of Neuroradiology, The National Hospital for Neurology and Neurosurgery, London (United Kingdom)

    2016-12-15

    The prognostic value of the dynamic contrast-enhanced (DCE) MRI perfusion and its histogram analysis-derived metrics is not well established for high-grade glioma (HGG) patients. The aim of this prospective study was to investigate DCE perfusion transfer coefficient (K{sup trans}), vascular plasma volume fraction (v{sub p}), extracellular volume fraction (v{sub e}), reverse transfer constant (k{sub ep}), and initial area under gadolinium concentration time curve (IAUGC) as predictors of progression-free (PFS) and overall survival (OS) in HGG patients. Sixty-nine patients with suspected anaplastic astrocytoma or glioblastoma underwent preoperative DCE-MRI scans. DCE perfusion whole tumor region histogram parameters, clinical details, and PFS and OS data were obtained. Univariate, multivariate, and Kaplan-Meier survival analyses were conducted. Receiver operating characteristic (ROC) curve analysis was employed to identify perfusion parameters with the best differentiation performance. On univariate analysis, v{sub e} and skewness of v{sub p} had significant negative impacts, while k{sub ep} had significant positive impact on OS (P < 0.05). v{sub e} was also a negative predictor of PFS (P < 0.05). Patients with lower v{sub e} and IAUGC had longer median PFS and OS on Kaplan-Meier analysis (P < 0.05). K{sup trans} and v{sub e} could also differentiate grade III from IV gliomas (area under the curve 0.819 and 0.791, respectively). High v{sub e} is a consistent predictor of worse PFS and OS in HGG glioma patients. v{sub p} skewness and k{sub ep} are also predictive for OS. K{sup trans} and v{sub e} demonstrated the best diagnostic performance for differentiating grade III from IV gliomas. (orig.)

  9. Perfusion MRI of brain tumours: a comparative study of pseudo-continuous arterial spin labelling and dynamic susceptibility contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jaernum, Hanna; Steffensen, Elena G.; Simonsen, Carsten Wiberg; Jensen, Finn Taagehoej [Aalborg Hospital/Aarhus University Hospital, Department of Radiology, Aalborg (Denmark); Knutsson, Linda [Lund University, Department of Medical Radiation Physics, Lund (Sweden); Fruend, Ernst-Torben [Aalborg Hospital/Aarhus University Hospital, Department of Radiology, Aalborg (Denmark); GE Healthcare - Applied Science Lab Europe, Aalborg (Denmark); Lundbye-Christensen, Soeren [Aalborg Hospital/Aarhus University Hospital, Department of Cardiology, Center for Cardiovascular Research, Aalborg (Denmark); Shankaranarayanan, Ajit [Global Applied Science Lab, GE Healthcare, Menlo Park, CA (United States); Alsop, David C. [Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA (United States); Larsson, Elna-Marie [Aalborg Hospital/Aarhus University Hospital, Department of Radiology, Aalborg (Denmark); Uppsala University Hospital, Department of Radiology, Uppsala (Sweden)

    2010-04-15

    The purpose of this study was to compare the non-invasive 3D pseudo-continuous arterial spin labelling (PC ASL) technique with the clinically established dynamic susceptibility contrast perfusion magnetic resonance imaging (DSC-MRI) for evaluation of brain tumours. A prospective study of 28 patients with contrast-enhancing brain tumours was performed at 3 T using DSC-MRI and PC ASL with whole-brain coverage. The visual qualitative evaluation of signal enhancement in tumour was scored from 0 to 3 (0 = no signal enhancement compared with white matter, 3 = pronounced signal enhancement with equal or higher signal intensity than in grey matter/basal ganglia). The extent of susceptibility artefacts in the tumour was scored from 0 to 2 (0 = no susceptibility artefacts and 2 = extensive susceptibility artefacts (maximum diameter > 2 cm)). A quantitative analysis was performed with normalised tumour blood flow values (ASL nTBF, DSC nTBF): mean value for region of interest (ROI) in an area with maximum signal enhancement/the mean value for ROIs in cerebellum. There was no difference in total visual score for signal enhancement between PC ASL and DSC relative cerebral blood flow (p = 0.12). ASL had a lower susceptibility-artefact score than DSC-MRI (p = 0.03). There was good correlation between DSC nTBF and ASL nTBF values with a correlation coefficient of 0.82. PC ASL is an alternative to DSC-MRI for the evaluation of perfusion in brain tumours. The method has fewer susceptibility artefacts than DSC-MRI and can be used in patients with renal failure because no contrast injection is needed. (orig.)

  10. Correlation of Perfusion MRI and 18F-FDG PET Imaging Biomarkers for Monitoring Regorafenib Therapy in Experimental Colon Carcinomas with Immunohistochemical Validation

    Science.gov (United States)

    Eschbach, Ralf S.; Fendler, Wolfgang P.; Kazmierczak, Philipp M.; Hacker, Marcus; Rominger, Axel; Carlsen, Janette; Hirner-Eppeneder, Heidrun; Schuster, Jessica; Moser, Matthias; Havla, Lukas; Schneider, Moritz J.; Ingrisch, Michael; Spaeth, Lukas; Reiser, Maximilian F.; Nikolaou, Konstantin; Cyran, Clemens C.

    2015-01-01

    Objectives To investigate a multimodal, multiparametric perfusion MRI / 18F-fluoro-deoxyglucose-(18F-FDG)-PET imaging protocol for monitoring regorafenib therapy effects on experimental colorectal adenocarcinomas in rats with immunohistochemical validation. Materials and Methods Human colorectal adenocarcinoma xenografts (HT-29) were implanted subcutaneously in n = 17 (n = 10 therapy group; n = 7 control group) female athymic nude rats (Hsd:RH-Foxn1rnu). Animals were imaged at baseline and after a one-week daily treatment protocol with regorafenib (10 mg/kg bodyweight) using a multimodal, multiparametric perfusion MRI/18F-FDG-PET imaging protocol. In perfusion MRI, quantitative parameters of plasma flow (PF, mL/100 mL/min), plasma volume (PV, %) and endothelial permeability-surface area product (PS, mL/100 mL/min) were calculated. In 18F-FDG-PET, tumor-to-background-ratio (TTB) was calculated. Perfusion MRI parameters were correlated with TTB and immunohistochemical assessments of tumor microvascular density (CD-31) and cell proliferation (Ki-67). Results Regorafenib significantly (pregorafenib therapy effects on experimental colorectal adenocarcinomas in vivo with significant correlations between perfusion MRI parameters and 18F-FDG-PET validated by immunohistochemistry. PMID:25668193

  11. MRI methods for pulmonary ventilation and perfusion imaging; Methoden der MRT zur Ventilations- und Perfusionsbildgebung der Lunge

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, G. [Universitaetsspital Basel, Klinik fuer Radiologie und Nuklearmedizin, Basel (Switzerland); Bauman, G. [Universitaetsspital Basel, Klinik fuer Radiologie und Nuklearmedizin - Radiologische Physik, Basel (Switzerland)

    2016-02-15

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O{sub 2}-enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies. (orig.) [German] Die separate Beurteilung von Atemmechanik, Gasaustauschprozessen und Lungenzirkulation ist wesentlich fuer die Diagnose und Therapie von Lungenerkrankungen. Klinische Lungenfunktionstests sind aufgrund ihrer zumeist nur globalen Aussage oft nicht hinreichend spezifisch in der Differenzialdiagnostik oder eingeschraenkt sensitiv bei der

  12. Stress cine MRI for detection of coronary artery disease

    International Nuclear Information System (INIS)

    Sommer, T.; Hofer, U.; Schild, H.

    2002-01-01

    Stress testing is the cornerstone in the diagnosis of patients with suspected coronary artery disease (CAD). Stress echocardiography has become a well-established modality for the detection of ischemia-induced wall motion abnormalities. However, display and reliable interpretation of stress echocardiography studies are user-dependent, the test reproducibility is low, and 10 to 15% of patients yield suboptimal or non-diagnostic images. Due to its high spatial and contrast resolution, MRI is known to permit an accurate determination of left ventricular function and wall thickness at rest. Early stress MRI studies provided promising results with respect to the detection of CAD. However, the clinical impact was limited due to long imaging time and problematic patient monitoring in the MRI environment. Recent technical improvements - namely ultrafast MR image acquisition - led to a significant reduction of imaging time and improved patient safety. Stress can be induced by physical exercise or pharmacologically by administration of a beta 1 -agonist (dobutamine) or vasodilatator (dipyridamole and adenosine). The best developed and most promising stress MRI technique is a high-dose dobutamine/atropine stress protocol (10, 20, 30, 40 μg/kg/min; optionally 0.25-mg fractions of atropine up to maximal dose 1 mg). Severe complications (myocardial infarction, ventricular fibrillation and sustained tachycardia, cardiogenic shock) may be expected in 0.25% of patients. Currently, data of three high-dose dobutamine stress MRI studies are available, revealing a good sensitivity (83 - 87%) and specificity (83 - 86%) in the assessment of CAD. The direct comparison between echocardiography and MRI for the detection of stress-induced wall motion abnormalities yielded better results for dobutamine-MRI in terms of sensitivity (86.2% vs. 74.3%; p [de

  13. Evaluation of dynamic contrast-enhanced T1-weighted perfusion MRI in the differentiation of tumor recurrence from radiation necrosis

    DEFF Research Database (Denmark)

    Larsen, Anne Vibeke Andrée; Simonsen, Helle J; Law, Ian

    2013-01-01

    INTRODUCTION: To investigate if perfusion measured with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) can be used to differentiate radiation necrosis from tumor recurrence in patients with high-grade glioma. METHODS: The study was approved by the institutional review board...... to measure cerebral blood volume (CBV), blood-brain barrier (BBB) permeability and cerebral blood flow (CBF). Subjects also underwent FDG-PET and lesions were classified as either metabolically active or inactive. Follow-up clinical MRI and lesion histology in case of additional tissue resection was used...... to determine whether lesions were regressing or progressing. RESULTS: Fourteen enhancing lesions could be classified as progressing (11) or regressing (three). An empirical threshold of 2.0 ml/100 g for CBV allowed detection of regressing lesions with a sensitivity of 100 % and specificity of 100 %. FDG-PET...

  14. 3D pulmonary perfusion MRI and MR angiography of pulmonary embolism in pigs after a single injection of a blood pool MR contrast agent

    International Nuclear Information System (INIS)

    Fink, Christian; Ley, Sebastian; Puderbach, Michael; Plathow, Christian; Kauczor, Hans-Ulrich; Bock, Michael

    2004-01-01

    The purpose of this study was to assess the feasibility of contrast-enhanced 3D perfusion MRI and MR angiography (MRA) of pulmonary embolism (PE) in pigs using a single injection of the blood pool contrast Gadomer. PE was induced in five domestic pigs by injection of autologous blood thrombi. Contrast-enhanced first-pass 3D perfusion MRI (TE/TR/FA: 1.0 ms/2.2 ms/40 ; voxel size: 1.3 x 2.5 x 4.0 mm 3 ; TA: 1.8 s per data set) and high-resolution 3D MRA (TE/TR/FA: 1.4 ms/3.4 ms/40 ; voxel size: 0.8 x 1.0 x 1.6 mm 3 ) was performed during and after a single injection of 0.1 mmol/kg body weight of Gadomer. Image data were compared to pre-embolism Gd-DTPA-enhanced MRI and post-embolism thin-section multislice CT (n=2). SNR measurements were performed in the pulmonary arteries and lung. One animal died after induction of PE. In all other animals, perfusion MRI and MRA could be acquired after a single injection of Gadomer. At perfusion MRI, PE could be detected by typical wedge-shaped perfusion defects. While the visualization of central PE at MRA correlated well with the CT, peripheral PE were only visualized by CT. Gadomer achieved a higher peak SNR of the lungs compared to Gd-DTPA (21±8 vs. 13±3). Contrast-enhanced 3D perfusion MRI and MRA of PE can be combined using a single injection of the blood pool contrast agent Gadomer. (orig.)

  15. Non-contrast-enhanced perfusion and ventilation assessment of the human lung by means of fourier decomposition in proton MRI.

    Science.gov (United States)

    Bauman, Grzegorz; Puderbach, Michael; Deimling, Michael; Jellus, Vladimir; Chefd'hotel, Christophe; Dinkel, Julien; Hintze, Christian; Kauczor, Hans-Ulrich; Schad, Lothar R

    2009-09-01

    Assessment of regional lung perfusion and ventilation has significant clinical value for the diagnosis and follow-up of pulmonary diseases. In this work a new method of non-contrast-enhanced functional lung MRI (not dependent on intravenous or inhalative contrast agents) is proposed. A two-dimensional (2D) true fast imaging with steady precession (TrueFISP) pulse sequence (TR/TE = 1.9 ms/0.8 ms, acquisition time [TA] = 112 ms/image) was implemented on a 1.5T whole-body MR scanner. The imaging protocol comprised sets of 198 lung images acquired with an imaging rate of 3.33 images/s in coronal and sagittal view. No electrocardiogram (ECG) or respiratory triggering was used. A nonrigid image registration algorithm was applied to compensate for respiratory motion. Rapid data acquisition allowed observing intensity changes in corresponding lung areas with respect to the cardiac and respiratory frequencies. After a Fourier analysis along the time domain, two spectral lines corresponding to both frequencies were used to calculate the perfusion- and ventilation-weighted images. The described method was applied in preliminary studies on volunteers and patients showing clinical relevance to obtain non-contrast-enhanced perfusion and ventilation data.

  16. Investigation of the mechanisms mediating MDMA "Ecstasy"-induced increases in cerebro-cortical perfusion determined by btASL MRI.

    Science.gov (United States)

    Rouine, J; Kelly, M E; Jennings-Murphy, C; Duffy, P; Gorman, I; Gormley, S; Kerskens, C M; Harkin, Andrew

    2015-05-01

    Acute administration of the recreational drug of abuse 3,4-methylenedioxymethamphetamine (MDMA; Ecstasy) has previously been shown to increase cerebro-cortical perfusion as determined by bolus-tracking arterial spin labelling (btASL) MRI. The purpose of the current study was to assess the mechanisms mediating these changes following systemic administration of MDMA to rats. Pharmacological manipulation of serotonergic, dopaminergic and nitrergic transmission was carried out to determine the mechanism of action of MDMA-induced increases in cortical perfusion using btASL MRI. Fenfluramine (10 mg/kg), like MDMA (20 mg/kg), increased cortical perfusion. Increased cortical perfusion was not obtained with the 5-HT2 receptor agonist 2,5-dimethoxy-4-iodophenyl-aminopropane hydrochloride (DOI) (1 mg/kg). Depletion of central 5-HT following systemic administration of the tryptophan hydroxylase inhibitor para-chlorophenylalanine (pCPA) produced effects similar to those observed with MDMA. Pre-treatment with the 5-HT receptor antagonist metergoline (4 mg/kg) or with the 5-HT reuptake inhibitor citalopram (30 mg/kg), however, failed to produce any effect alone or influence the response to MDMA. Pre-treatment with the dopamine D1 receptor antagonist SCH 23390 (1 mg/kg) failed to influence the changes in cortical perfusion obtained with MDMA. Treatment with the neuronal nitric oxide (NO) synthase inhibitor 7-nitroindazole (7-NI) (25 mg/kg) provoked no change in cerebral perfusion alone yet attenuated the MDMA-related increase in cortical perfusion. Cortical 5-HT depletion is associated with increases in perfusion although this mechanism alone does not account for MDMA-related changes. A role for NO, a key regulator of cerebrovascular perfusion, is implicated in MDMA-induced increases in cortical perfusion.

  17. Pretest clinical diagnosis of coronary artery disease and stress myocardial perfusion scintigram

    International Nuclear Information System (INIS)

    Kasalicky, J.; Kovac, I.; Lanska, V.

    2001-01-01

    To assess the probability of perfusion defects at exercise stress myocardial perfusion SPECT scintigraphy from pretest clinical diagnosis (medical personal history, previous ergometric investigation). To determine the value of clinical factors for probability of scintigraphic defects with respect to avoiding unnecessary investigation in subjects with low probability of abnormal scintigrams. 2143 subjects (1235 men, 908 women) were investigated by SPECT perfusion scintigraphy at stepwise increasing exercise stress. They were divided into three groups with regard to their medical history and exercise test at scintigraphy: subjects without any signs of coronary artery disease (CAD), patients with high likelihood of CAD (i.e., typical anginal pain, in particular at stress, positive stress ECG changes, angiographically documented important CAD) and patients after myocardial infarction (MI). Important risk factors (hypertension, diabetes, age and sex), as well as the role of revascularisation procedures, were taken into account for multiple logistic regression in order to express their importance for the odds of scintigraphic defect visualisation. Perfusion scintigraphic defects (PSD) were found in 5.2% of subjects without signs of CAD, in contrast to patients with manifest CAD (68.8% with PSD) and in those after MI (90.2% with PSD). There were other important factors corroborating the likelihood of PSD (in decreasing order of importance): diabetes, male, ECG changes at stress, increasing age. Successful revascularisation improved scintigraphic images. The examination of CAD symptom-free subjects, in particular with atypical chest discomfort, is useless. SMPS in patients after documented MI is to be carried out for other intended purposes, not for CAD diagnosis only. SMPS is highly recommended in patients with CAD symptoms and high CAD probability in order to decide further treatment and prognosis. (author)

  18. Quantification of renal allograft perfusion using arterial spin labeling MRI: initial results.

    Science.gov (United States)

    Lanzman, Rotem S; Wittsack, Hans-Jörg; Martirosian, Petros; Zgoura, Panagiota; Bilk, Philip; Kröpil, Patric; Schick, Fritz; Voiculescu, Adina; Blondin, Dirk

    2010-06-01

    To quantify renal allograft perfusion in recipients with stable allograft function and acute decrease in allograft function using nonenhanced flow-sensitive alternating inversion recovery (FAIR)-TrueFISP arterial spin labeling (ASL) MR imaging. Following approval of the local ethics committee, 20 renal allograft recipients were included in this study. ASL perfusion measurement and an anatomical T2-weighted single-shot fast spin-echo (HASTE) sequence were performed on a 1.5-T scanner (Magnetom Avanto, Siemens, Erlangen, Germany). T2-weighted MR urography was performed in patients with suspected ureteral obstruction. Patients were assigned to three groups: group a, 6 patients with stable allograft function over the previous 4 months; group b, 7 patients with good allograft function who underwent transplantation during the previous 3 weeks; group c, 7 allograft recipients with an acute deterioration of renal function. Mean cortical perfusion values were 304.8 +/- 34.4, 296.5 +/- 44.1, and 181.9 +/- 53.4 mg/100 ml/min for groups a, b and c, respectively. Reduction in cortical perfusion in group c was statistically significant. Our results indicate that ASL is a promising technique for nonenhanced quantification of cortical perfusion of renal allografts. Further studies are required to determine the clinical value of ASL for monitoring renal allograft recipients.

  19. Quantification of renal allograft perfusion using arterial spin labeling MRI: initial results

    International Nuclear Information System (INIS)

    Lanzman, Rotem S.; Wittsack, Hans-Joerg; Bilk, Philip; Kroepil, Patric; Blondin, Dirk; Martirosian, Petros; Schick, Fritz; Zgoura, Panagiota; Voiculescu, Adina

    2010-01-01

    To quantify renal allograft perfusion in recipients with stable allograft function and acute decrease in allograft function using nonenhanced flow-sensitive alternating inversion recovery (FAIR)-TrueFISP arterial spin labeling (ASL) MR imaging. Following approval of the local ethics committee, 20 renal allograft recipients were included in this study. ASL perfusion measurement and an anatomical T2-weighted single-shot fast spin-echo (HASTE) sequence were performed on a 1.5-T scanner (Magnetom Avanto, Siemens, Erlangen, Germany). T2-weighted MR urography was performed in patients with suspected ureteral obstruction. Patients were assigned to three groups: group a, 6 patients with stable allograft function over the previous 4 months; group b, 7 patients with good allograft function who underwent transplantation during the previous 3 weeks; group c, 7 allograft recipients with an acute deterioration of renal function. Mean cortical perfusion values were 304.8 ± 34.4, 296.5 ± 44.1, and 181.9 ± 53.4 mg/100 ml/min for groups a, b and c, respectively. Reduction in cortical perfusion in group c was statistically significant. Our results indicate that ASL is a promising technique for nonenhanced quantification of cortical perfusion of renal allografts. Further studies are required to determine the clinical value of ASL for monitoring renal allograft recipients. (orig.)

  20. Dipyridamole stress myocardial perfusion by computed tomography in patients with left bundle branch block

    OpenAIRE

    Cabeda, Est?van Vieira; Falc?o, Andr?a Maria Gomes; Soares Jr., Jos?; Rochitte, Carlos Eduardo; Nomura, C?sar Higa; ?vila, Luiz Francisco Rodrigues; Parga, Jos? Rodrigues

    2015-01-01

    Abstract Background: Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). Objective: To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and comp...

  1. Thallium-201 peripheral perfusion scans: feasibility of single-dose, single-day, rest and stress study

    International Nuclear Information System (INIS)

    Siegel, M.E.; Stewart, C.A.

    1981-01-01

    The distribution and redistribution kinetics of thallium-201 in the lower extremities were investigated to determine the relationships among the rest, stress, and delayed-stress perfusion studies. The distribution of perfusion when the tracer was administered at rest was compared with that when administered during stress, and the distribution 5 to 6 h after the stress injection. In nine of 10 subjects without peripheral vascular disease, the 5 to 6 h poststress redistribution pattern was unchanged from the stress pattern and was different from the rest pattern. However, in all patients with peripheral vascular disease, the delayed poststress perfusion distribution had greater similarity to the rest pattern and was substantially different from that noted immediately after stress. Using the time frame of this study, the stress and delayed-stress 201 Tl perfusion study of the lower extremities cannot be used to represent true rest perfusion. However, because of the similarity of the delayed-stress to the true rest distribution in abnormals, it may be clinically useful in defining rest and stress alterations

  2. Thallium-201 peripheral perfusion scans: feasibility of single-dose, single-day, rest and stress study

    International Nuclear Information System (INIS)

    Siegel, M.E.; Stewart, C.A.

    1981-01-01

    The distribution and redistribution kinetics of thallium-201 in the lower extremities were investigated to determine the relationships among the rest, stress, and delayed-stress perfusion studies. The distribution of perfusion when the tracer was administered at rest was compared with that when administered during stress, and the distribution 5--6 hr after the stress injection. The distribution was evaluated qualitatively by scanning and quantitatively by point counting. In nine of 10 subjects without peripheral vascular disease, the 5--6 poststress redistribution pattern was unchanged from the stress pattern and was different from the rest pattern. However, in all patients with peripheral vascular disease, the delayed poststress perfusion distribution had greater similarity to the rest pattern and was substantially different from that noted immediately after stress. Using the time frame of this study, the stress and delayed-stress 201 Tl perfusion study of the lower extremities cannot be used to represent true rest perfusion. However, because of the similarity of the delayed-stress to the true rest distribution in abnormals, it may be clinically useful in defining rest and stress alterations

  3. Prevalence and predictors of an abnormal stress myocardial perfusion study in asymptomatic patients with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Scholte, Arthur J.H.A.; Schuijf, Joanne D.; Wall, Ernst E. van der; Bax, Jeroen J.; Kharagjitsingh, Antje V.; Dibbets-Schneider, Petra; Stokkel, Marcel P.

    2009-01-01

    The purpose of this study was to evaluate the prevalence of an abnormal stress myocardial perfusion study in a cohort of truly asymptomatic patients with type 2 diabetes mellitus using myocardial perfusion imaging by means of single photon emission computed tomography (SPECT). Secondly, we determined which clinical characteristics may predict an abnormal stress myocardial perfusion study in this population. A total of 120 asymptomatic patients (mean age 53±10 years) with type 2 diabetes mellitus and one or more risk factors for coronary artery disease were prospectively recruited from an outpatient diabetes clinic. All patients underwent myocardial perfusion imaging by means of adenosine 99m Tc sestamibi SPECT. Images were evaluated for the presence of perfusion abnormalities as well as other nonperfusion abnormalities that may indicate extensive ischaemia, including left ventricular dysfunction (defined as a left ventricular ejection fraction <45%), transient ischaemic dilatation and adenosine-induced ST segment depression. Multivariable analysis was performed using a backward selection strategy to identify potential predictors for an abnormal stress myocardial perfusion study. Finally, all patients were followed up for 12 months to determine the occurrence of cardiovascular events: (1) cardiac death, (2) nonfatal myocardial infarction, (3) unstable angina requiring hospitalization, (4) revascularization, or (5) stroke. Of the 120 patients, 40 (33%) had an abnormal stress study, including myocardial perfusion abnormalities in 30 patients (25%). In 10 patients (8%), indicators of extensive (possibly balanced ischaemia) were observed in the absence of abnormal perfusion. The multivariable analysis identified current smoking, duration of diabetes and the cholesterol/high-density lipoprotein (HDL) ratio as independent predictors of an abnormal stress study. During a follow-up period of 12 months six patients (5%) had a cardiovascular event. The current study revealed

  4. ¹⁸F-FDG PET metabolic parameters and MRI perfusion and diffusion parameters in hepatocellular carcinoma: a preliminary study.

    Directory of Open Access Journals (Sweden)

    Sung Jun Ahn

    Full Text Available OBJECTIVES: Glucose metabolism, perfusion, and water diffusion may have a relationship or affect each other in the same tumor. The understanding of their relationship could expand the knowledge of tumor characteristics and contribute to the field of oncologic imaging. The purpose of this study was to evaluate the relationships between metabolism, vasculature and cellularity of advanced hepatocellular carcinoma (HCC, using multimodality imaging such as ¹⁸F-FDG positron emission tomography (PET, dynamic contrast enhanced (DCE-MRI, and diffusion weighted imaging(DWI. MATERIALS AND METHODS: Twenty-one patients with advanced HCC underwent ¹⁸F-FDG PET, DCE-MRI, and DWI before treatment. Maximum standard uptake values (SUV(max from ¹⁸F-FDG-PET, variables of the volume transfer constant (K(trans from DCE-MRI and apparent diffusion coefficient (ADC from DWI were obtained for the tumor and their relationships were examined by Spearman's correlation analysis. The influence of portal vein thrombosis on SUV(max and variables of K(trans and ADC was evaluated by Mann-Whitney test. RESULTS: SUV(max showed significant negative correlation with K(trans(max (ρ = -0.622, p = 0.002. However, variables of ADC showed no relationship with variables of K(trans or SUV(max (p>0.05. Whether portal vein thrombosis was present or not did not influence the SUV max and variables of ADC and K(trans (p>0.05. CONCLUSION: In this study, SUV was shown to be correlated with K(trans in advanced HCCs; the higher the glucose metabolism a tumor had, the lower the perfusion it had, which might help in guiding target therapy.

  5. Diagnostic performance of semi-quantitative and quantitative stress CMR perfusion analysis: a meta-analysis.

    Science.gov (United States)

    van Dijk, R; van Assen, M; Vliegenthart, R; de Bock, G H; van der Harst, P; Oudkerk, M

    2017-11-27

    Stress cardiovascular magnetic resonance (CMR) perfusion imaging is a promising modality for the evaluation of coronary artery disease (CAD) due to high spatial resolution and absence of radiation. Semi-quantitative and quantitative analysis of CMR perfusion are based on signal-intensity curves produced during the first-pass of gadolinium contrast. Multiple semi-quantitative and quantitative parameters have been introduced. Diagnostic performance of these parameters varies extensively among studies and standardized protocols are lacking. This study aims to determine the diagnostic accuracy of semi- quantitative and quantitative CMR perfusion parameters, compared to multiple reference standards. Pubmed, WebOfScience, and Embase were systematically searched using predefined criteria (3272 articles). A check for duplicates was performed (1967 articles). Eligibility and relevance of the articles was determined by two reviewers using pre-defined criteria. The primary data extraction was performed independently by two researchers with the use of a predefined template. Differences in extracted data were resolved by discussion between the two researchers. The quality of the included studies was assessed using the 'Quality Assessment of Diagnostic Accuracy Studies Tool' (QUADAS-2). True positives, false positives, true negatives, and false negatives were subtracted/calculated from the articles. The principal summary measures used to assess diagnostic accuracy were sensitivity, specificity, andarea under the receiver operating curve (AUC). Data was pooled according to analysis territory, reference standard and perfusion parameter. Twenty-two articles were eligible based on the predefined study eligibility criteria. The pooled diagnostic accuracy for segment-, territory- and patient-based analyses showed good diagnostic performance with sensitivity of 0.88, 0.82, and 0.83, specificity of 0.72, 0.83, and 0.76 and AUC of 0.90, 0.84, and 0.87, respectively. In per territory

  6. Limbic system perfusion in Alzheimer's disease measured by MRI-coregistered HMPAO SPET

    International Nuclear Information System (INIS)

    Callen, David J.A.; Black, Sandra E.; Caldwell, Curtis B.

    2002-01-01

    The goal of this study was to perform a systematic, semi-quantitative analysis of limbic perfusion in patients with Alzheimer's disease (AD) using coregistered single-photon emission tomography (SPET) images aligned to magnetic resonance (MR) images. Limbic perfusion in 40 patients with mild to moderate AD was compared with that of 17 age-, sex-, and education-matched normal controls (NC). HMPAO SPET scans and 3D T1-weighted MR images were acquired for each subject. Structures of the limbic system (i.e. hippocampus, amygdala, anterior thalamus, hypothalamus, mamillary bodies, basal forebrain, septal area and cingulate, orbitofrontal and parahippocampal cortices) were traced on the MR images and transferred to the coregistered SPET scans. Perfusion ratios for all limbic regions were calculated relative to cerebellar perfusion. General linear model multivariate analysis revealed that, overall, limbic structures showed significant hypoperfusion (F=7.802, P 2 =0.695) in AD patients compared with NC. Greatest differences (d≥0.8) were found in the hippocampus, as well as all areas of the cingulate cortex. Significant relative hypoperfusion was also apparent in the parahippocampal cortex, amygdala/entorhinal cortex, septal area and anterior thalamus, all of which showed medium to large effect sizes (d=0.6-0.8). No significant relative perfusion differences were detected in the basal forebrain, hypothalamus, mamillary bodies or orbitofrontal cortex. Logistic regression indicated that posterior cingulate cortex perfusion was able to discriminate AD patients from NC with 93% accuracy (95% sensitivity, 88% specificity). The current results suggest that most, but not all, limbic structures show significant relative hypoperfusion in AD. These findings validate previous post-mortem studies and could be useful in improving diagnostic accuracy, monitoring disease progression and evaluating potential treatment strategies in AD. (orig.)

  7. Limbic system perfusion in Alzheimer's disease measured by MRI-coregistered HMPAO SPET

    Energy Technology Data Exchange (ETDEWEB)

    Callen, David J.A. [Institute of Medical Science, Research Program in Aging, Imaging, Sunnybrook and Women' s University of Toronto, ON (Canada); Black, Sandra E. [Cognitive Neurology Unit and Research Program in Aging, Sunnybrook and Women' s College Health Sciences Centre, Toronto, ON (Canada); Institute of Medical Science, Research Program in Aging, Imaging, Sunnybrook and Women' s University of Toronto, ON (Canada); Department of Medicine (Neurology), University of Toronto, ON (Canada); Caldwell, Curtis B. [Department of Medical Imaging, Sunnybrook and Women' s College Health Sciences Centre and University of Toronto, CN (Canada)

    2002-07-01

    The goal of this study was to perform a systematic, semi-quantitative analysis of limbic perfusion in patients with Alzheimer's disease (AD) using coregistered single-photon emission tomography (SPET) images aligned to magnetic resonance (MR) images. Limbic perfusion in 40 patients with mild to moderate AD was compared with that of 17 age-, sex-, and education-matched normal controls (NC). HMPAO SPET scans and 3D T1-weighted MR images were acquired for each subject. Structures of the limbic system (i.e. hippocampus, amygdala, anterior thalamus, hypothalamus, mamillary bodies, basal forebrain, septal area and cingulate, orbitofrontal and parahippocampal cortices) were traced on the MR images and transferred to the coregistered SPET scans. Perfusion ratios for all limbic regions were calculated relative to cerebellar perfusion. General linear model multivariate analysis revealed that, overall, limbic structures showed significant hypoperfusion (F=7.802, P<0.00001, {eta}{sup 2}=0.695) in AD patients compared with NC. Greatest differences (d{>=}0.8) were found in the hippocampus, as well as all areas of the cingulate cortex. Significant relative hypoperfusion was also apparent in the parahippocampal cortex, amygdala/entorhinal cortex, septal area and anterior thalamus, all of which showed medium to large effect sizes (d=0.6-0.8). No significant relative perfusion differences were detected in the basal forebrain, hypothalamus, mamillary bodies or orbitofrontal cortex. Logistic regression indicated that posterior cingulate cortex perfusion was able to discriminate AD patients from NC with 93% accuracy (95% sensitivity, 88% specificity). The current results suggest that most, but not all, limbic structures show significant relative hypoperfusion in AD. These findings validate previous post-mortem studies and could be useful in improving diagnostic accuracy, monitoring disease progression and evaluating potential treatment strategies in AD. (orig.)

  8. MRI for the assessment of organ perfusion in patients with chronic kidney disease.

    Science.gov (United States)

    Odudu, Aghogho; Francis, Susan T; McIntyre, Christopher W

    2012-11-01

    Recent data have highlighted the importance of quantitative measures of organ perfusion and functional reserve. Magnetic resonance imaging allows the assessment of markers of perfusion without the use of contrast media. Techniques such as arterial spin labelling (ASL) and blood oxygen level-dependent (BOLD) imaging have been available for some time, but advances in the technology and concerns over the safety of contrast media in renal disease have spurred renewed interest and development. ASL measures perfusion, whereas BOLD imaging provides a marker of blood oxygenation, arising from the compound effect of a number of measures including perfusion, blood volume and oxygen consumption; thus, the techniques are complementary rather than analogous. They were initially confined to brain imaging as inherently low signal, susceptibility effects and motion limited their use in thoracic and abdominal organs. Advances in technology have led to robust sequences that can quantify clinically relevant changes and correlate well with reference standards. Novel approaches are likely to accelerate translation into clinical practice. The noninvasive and repeatable nature of ASL and BOLD imaging makes it likely that they will be increasingly used in clinical research. Using a developmental framework, we suggest that the application of these techniques to thoracic and abdominal organs requires validation before they are suitable for generalized clinical use. The demand for these techniques is likely to be driven by the incentive to avoid the use of contrast media.

  9. Quantification of myocardial perfusion using free-breathing MRI and prospective slice tracking

    DEFF Research Database (Denmark)

    Pedersen, Henrik; Kelle, Sebastian; Ringgaard, Steffen

    2009-01-01

    . This study demonstrates the feasibility of patient-adapted 3D PST on a 3.0 Tesla MR system. Eight patients underwent free-breathing studies of myocardial perfusion, simultaneously collecting data with and without PST. On average, PST reduced residual in-plane motion by a factor of 2, compared...

  10. MRI-CEST assessment of tumour perfusion using X-ray iodinated agents: comparison with a conventional Gd-based agent

    Energy Technology Data Exchange (ETDEWEB)

    Anemone, Annasofia; Consolino, Lorena [Universita degli Studi di Torino, Dipartimento di Biotecnologie Molecolari e Scienze per la Salute, Torino (Italy); Longo, Dario Livio [Universita degli Studi di Torino, Istituto di Biostrutture e Bioimmagini (CNR) c/o Centro di Biotecnologie Molecolari, Torino (Italy)

    2017-05-15

    X-ray iodinated contrast media have been shown to generate contrast in MR images when used with the chemical exchange saturation transfer (CEST) approach. The aim of this study is to compare contrast enhancement (CE) capabilities and perfusion estimates between radiographic molecules and a Gd-based contrast agent in two tumour murine models with different vascularization patterns. MRI-CEST and MRI-CE T{sub 1w} images were acquired in murine TS/A and 4 T1 breast tumours upon sequential i.v. injection of iodinated contrast media (iodixanol, iohexol, and iopamidol) and of gadoteridol. The signal enhancements observed in the two acquisition modalities were evaluated using Pearson's correlation, and the correspondence in the spatial distribution was assessed by a voxelwise comparison. A significant, positive correlation was observed between iodinated contrast media and gadoteridol for tumour contrast enhancement and perfusion values for both tumour models (r = 0.51-0.62). High spatial correlations were observed in perfusion maps between iodinated molecules and gadoteridol (r = 0.68-0.86). Tumour parametric maps derived by iodinated contrast media and gadoteridol showed high spatial similarities. A good to strong spatial correlation between tumour perfusion parameters derived from MRI-CEST and MRI-CE modalities indicates that the two procedures provide similar information. (orig.)

  11. Comparison of first-pass and second-bolus dynamic susceptibility perfusion MRI in brain tumors

    International Nuclear Information System (INIS)

    Spampinato, M.V.; Besenski, Nada; Rumboldt, Zoran; Wooten, Caroline; Dorlon, Margaret

    2006-01-01

    Our goal was to evaluate whether the T1 shortening effect caused by contrast leakage into brain tumors, a well-known confounding effect in the quantification of relative cerebral blood volume (rCBV) measurements, may be corrected by the administration of a predose of gadolinium-DTPA. As part of their presurgical imaging protocol, 25 patients with primary brain tumors underwent two consecutive dynamic susceptibility-weighted contrast-enhanced (DSC) perfusion MR studies. Intratumoral rCBV measurements and normalized rCBV values obtained during the first-pass and second-bolus studies were compared (Wilcoxon signed-ranks test). The frequency of relatively increased rCBV ratios on the second-bolus study was compared between enhancing and non-enhancing neoplasms (Fisher's exact test). Postprocessing perfusion studies were evaluated for image quality on a scale of 0-3 (Wilcoxon signed-ranks test). Four studies were excluded due to unacceptable image quality. Mean normalized rCBVs were 9.04 (SD 4.64) for the first-pass and 7.99 (SD 3.84) for the second-bolus study. There was no statistically significant difference between the two perfusion studies in either intratumoral rCBV (P=0.237) or rCBV ratio (P=0.181). Five enhancing and four non-enhancing tumors showed a relative increase in rCBV ratio on the second-bolus study, without a significant difference between the groups. Image quality was not significantly different between perfusion studies. Our results did not demonstrate a significant difference between first-pass and second-bolus rCBV measurements in DSC perfusion MR imaging. The administration of a predose of gadolinium-DTPA does not appear to be an efficient way of compensating for the underestimation of intratumoral rCBV values due to the T1 shortening effect. (orig.)

  12. Comparison of adenosine stress and exercise stress 201Tl myocardial perfusion imaging for diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    Chen Guibing; Wu Hua; Jiang Ningyi; Liu Sheng; Lu Xianping; Liang Jiugen; Zhang Hong

    2007-01-01

    Objective: The aim of this study was to compare the diagnostic values of adenosine and exercise stress 201 Tl myocardial perfusion imaging for detecting coronary heart disease (CHD). Methods: 41 patients with suspected CHD were randomly divided into two groups. In one group adenosine stress was submitted, the exercise stress myocardial SPECT was performed in another. Coronary angiography (CAG) was performed in each patient within 2 weeks before or after SPECT. The result of CAG was taken as 'gold standard of CHD. They compared the diagnostic value of two methods. Results: In adenosine group, the sensitivity, specificity, positive predictive value, negative predictive value, accuracy are 92.86%, 57.14%, 81.25%, 80.00%, 80.95% respectively. In exercise stress group, are 100%, 60.0%, 71.43%, 100%, 80.00% respectively. Detection rates of coronary artery lesions were 66.67% and 72.22% in two groups respectively. Conclusion Adenosine stress testing and exercise stress testing 201 Tl myocardial perfusion imaging may provide similar value for detection of CHD. (authors)

  13. A methodology for generating normal and pathological brain perfusion SPECT images for evaluation of MRI/SPECT fusion methods: application in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Grova, C [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Jannin, P [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Biraben, A [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Buvat, I [INSERM U494, CHU Pitie Salpetriere, Paris (France); Benali, H [INSERM U494, CHU Pitie Salpetriere, Paris (France); Bernard, A M [Service de Medecine Nucleaire, Centre Eugene Marquis, Rennes (France); Scarabin, J M [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Gibaud, B [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France)

    2003-12-21

    Quantitative evaluation of brain MRI/SPECT fusion methods for normal and in particular pathological datasets is difficult, due to the frequent lack of relevant ground truth. We propose a methodology to generate MRI and SPECT datasets dedicated to the evaluation of MRI/SPECT fusion methods and illustrate the method when dealing with ictal SPECT. The method consists in generating normal or pathological SPECT data perfectly aligned with a high-resolution 3D T1-weighted MRI using realistic Monte Carlo simulations that closely reproduce the response of a SPECT imaging system. Anatomical input data for the SPECT simulations are obtained from this 3D T1-weighted MRI, while functional input data result from an inter-individual analysis of anatomically standardized SPECT data. The method makes it possible to control the 'brain perfusion' function by proposing a theoretical model of brain perfusion from measurements performed on real SPECT images. Our method provides an absolute gold standard for assessing MRI/SPECT registration method accuracy since, by construction, the SPECT data are perfectly registered with the MRI data. The proposed methodology has been applied to create a theoretical model of normal brain perfusion and ictal brain perfusion characteristic of mesial temporal lobe epilepsy. To approach realistic and unbiased perfusion models, real SPECT data were corrected for uniform attenuation, scatter and partial volume effect. An anatomic standardization was used to account for anatomic variability between subjects. Realistic simulations of normal and ictal SPECT deduced from these perfusion models are presented. The comparison of real and simulated SPECT images showed relative differences in regional activity concentration of less than 20% in most anatomical structures, for both normal and ictal data, suggesting realistic models of perfusion distributions for evaluation purposes. Inter-hemispheric asymmetry coefficients measured on simulated data were

  14. Correlation of perfusion MRI and 18F-FDG PET imaging biomarkers for monitoring regorafenib therapy in experimental colon carcinomas with immunohistochemical validation.

    Directory of Open Access Journals (Sweden)

    Ralf S Eschbach

    Full Text Available To investigate a multimodal, multiparametric perfusion MRI / 18F-fluoro-deoxyglucose-(18F-FDG-PET imaging protocol for monitoring regorafenib therapy effects on experimental colorectal adenocarcinomas in rats with immunohistochemical validation.Human colorectal adenocarcinoma xenografts (HT-29 were implanted subcutaneously in n = 17 (n = 10 therapy group; n = 7 control group female athymic nude rats (Hsd:RH-Foxn1rnu. Animals were imaged at baseline and after a one-week daily treatment protocol with regorafenib (10 mg/kg bodyweight using a multimodal, multiparametric perfusion MRI/18F-FDG-PET imaging protocol. In perfusion MRI, quantitative parameters of plasma flow (PF, mL/100 mL/min, plasma volume (PV, % and endothelial permeability-surface area product (PS, mL/100 mL/min were calculated. In 18F-FDG-PET, tumor-to-background-ratio (TTB was calculated. Perfusion MRI parameters were correlated with TTB and immunohistochemical assessments of tumor microvascular density (CD-31 and cell proliferation (Ki-67.Regorafenib significantly (p<0.01 suppressed PF (81.1±7.5 to 50.6±16.0 mL/100mL/min, PV (12.1±3.6 to 7.5±1.6% and PS (13.6±3.2 to 7.9±2.3 mL/100mL/min as well as TTB (3.4±0.6 to 1.9±1.1 between baseline and day 7. Immunohistochemistry revealed significantly (p<0.03 lower tumor microvascular density (CD-31, 7.0±2.4 vs. 16.1±5.9 and tumor cell proliferation (Ki-67, 434.0 ± 62.9 vs. 663.0 ± 98.3 in the therapy group. Perfusion MRI parameters ΔPF, ΔPV and ΔPS showed strong and significant (r = 0.67-0.78; p<0.01 correlations to the PET parameter ΔTTB and significant correlations (r = 0.57-0.67; p<0.03 to immunohistochemical Ki-67 as well as to CD-31-stainings (r = 0.49-0.55; p<0.05.A multimodal, multiparametric perfusion MRI/PET imaging protocol allowed for non-invasive monitoring of regorafenib therapy effects on experimental colorectal adenocarcinomas in vivo with significant correlations between perfusion MRI parameters and 18F

  15. Quantification of reversible perfusion abnormality using exercise-stress thallium SPECT before and after coronary revascularization

    International Nuclear Information System (INIS)

    Nagao, Kazuhiko; Nakata, Tomoaki; Tsuchihashi, Kazufumi

    1994-01-01

    Reversible myocardial perfusion abnormality was quantified by bull's eye and unfolded surface mapping methods in exercise thallium SPECT before and after coronary revascularization in 47 patients with angina pectoris, including 34 patients with previous myocardial infarction (PMI) and 13 with effort angina (AP). There was no difference in the incidence or extent of myocardial ischemia between the 2 groups before revascularization. However, the ischemic scores were significantly smaller in PMI group preoperatively than the reductions of the ischemic scores after revascularization. The ischemic scores, preoperatively estimated reversible perfusion abnormality was 32%, 69% and 48% of the improvement of the ischemic score (extent score, severity score, and ischemic area, respectively). Using the 3 ischemic scores, the improvement of perfusion abnormality was well predicted in 70-89% of AP patients but 35-57% of PMI patients. Thus, quantitative analysis in stress thallium SPECT is useful for detecting myocardial ischemia and evaluating the effect of coronary revascularization. However, about a half of myocardial viability was underestimated in one third of PMI patients by the conventional exercise-stress thallium SPECT study. (author)

  16. Stress test with adenosine in cerebral perfusion imaging for the diagnosis of ischemic cerebrovascular disease

    International Nuclear Information System (INIS)

    Yuan Gengbiao; Kuang Anren; Chen Xuehong; Li Xihuan; Feng Jianzhong

    2004-01-01

    Objective: This study purpose is to evaluate cerebrovascular response and reserve capacity (CVR, CVRC) by stress test with adenosine in cerebral perfusion imaging for the diagnosis of ischemic cerebrovascular diseases. Methods There were 25 patients suffered from transient ischemia attack and 16 patients suffered from occlusive cerebral artery in this study. The rest cerebral perfusion imaging was obtained 30 minutes post-injection of 99mTC-ethylene cysteinate dimmer. After 2-5 days, adenosine stress tests were performed. Adenosine (0.14 mg/kg min) was administered intravenously 3 minutes pre-injection of 99mTC-ECD.Under same condition, the rest and stress tests of cerebral perfusion imaging were performed. By visual and semiquantitative analysis, the results of the rest/stress imaging were divided into the following four patterns: A: The stress imaging showed an expand areas of hypoperfusion, asymmetry index (AI) was decreased; B: Rest imaging was normal but new hypoperfused areas appeared with AI index declining in stress test; C: The hypoperfused areas were decreased or disappeared in size with AI index increasing in stress test; D: No changes showed in cerebral perfusion imaging patterns and Al index between rest and stress tests. AI index was ratio of radio account of interest regions than average radio account of cerebella. Results It was found that A, B, C and D type were 24%,12%,56% and 8% respectively in the group of transient ischemia attack patients, and 31%,44%, 19% and 6% respectively in the group of occlusive cerebrovascular patients. In rest test, of 41 patients of cerebrovascular disease, there were 28 cases decreased of radio uptake, moreover in stress test, there were 38 case decreased of radio uptake, positive rate were 68.29% and 92.68% respectively. Compared to X±SD of AI index of rest/stress test, it is found to increasing and being significant statistics (p<0.01, Spass 8.0 statistics software). Conclusion: Adenosinal-induced vasodilatation

  17. Monitoring Cell Death in Regorafenib-Treated Experimental Colon Carcinomas Using Annexin-Based Optical Fluorescence Imaging Validated by Perfusion MRI.

    Directory of Open Access Journals (Sweden)

    Philipp M Kazmierczak

    Full Text Available To investigate annexin-based optical fluorescence imaging (OI for monitoring regorafenib-induced early cell death in experimental colon carcinomas in rats, validated by perfusion MRI and multiparametric immunohistochemistry.Subcutaneous human colon carcinomas (HT-29 in athymic rats (n = 16 were imaged before and after a one-week therapy with regorafenib (n = 8 or placebo (n = 8 using annexin-based OI and perfusion MRI at 3 Tesla. Optical signal-to-noise ratio (SNR and MRI tumor perfusion parameters (plasma flow PF, mL/100mL/min; plasma volume PV, % were assessed. On day 7, tumors underwent immunohistochemical analysis for tumor cell apoptosis (TUNEL, proliferation (Ki-67, and microvascular density (CD31.Apoptosis-targeted OI demonstrated a tumor-specific probe accumulation with a significant increase of tumor SNR under therapy (mean Δ +7.78±2.95, control: -0.80±2.48, p = 0.021. MRI detected a significant reduction of tumor perfusion in the therapy group (mean ΔPF -8.17±2.32 mL/100 mL/min, control -0.11±3.36 mL/100 mL/min, p = 0.036. Immunohistochemistry showed significantly more apoptosis (TUNEL; 11392±1486 vs. 2921±334, p = 0.001, significantly less proliferation (Ki-67; 1754±184 vs. 2883±323, p = 0.012, and significantly lower microvascular density (CD31; 107±10 vs. 182±22, p = 0.006 in the therapy group.Annexin-based OI allowed for the non-invasive monitoring of regorafenib-induced early cell death in experimental colon carcinomas, validated by perfusion MRI and multiparametric immunohistochemistry.

  18. Normal stress databases in myocardial perfusion scintigraphy – how many subjects do you need?

    DEFF Research Database (Denmark)

    Trägårdh, Elin; Sjöstrand, Karl; Edenbrandt, Lars

    2012-01-01

    ) for male, NC for female, attenuation‐corrected images (AC) for male and AC for female subjects. 126 male and 205 female subjects were included. The normal database was created by alternatingly computing the mean of all normal subjects and normalizing the subjects with respect to this mean, until...... convergence. Coefficients of variation (CV) were created for increasing number of included patients in the four different normal stress databases. Normal stress databases with ...Commercial normal stress databases in myocardial perfusion scintigraphy (MPS) commonly consist of 30–40 individuals. The aim of the study was to determine how many subjects are needed. Four normal stress databases were developed using patients who underwent 99mTc MPS: non‐corrected images (NC...

  19. Safety of adenosine stress myocardial perfusion imaging by a one-route infusion protocol

    International Nuclear Information System (INIS)

    Kawai, Yuko; Kishino, Koh

    2006-01-01

    When adenosine stress testing is performed, a vein is generally accessed in each arm. To determine whether the one-route infusion protocol, that is, infusion via one upper arm vein, is safe, myocardial perfusion imaging was performed during adenosine stress testing in patients with angina pectoris. Sixty-six consecutive patients (43 men, 68±11 years of age) with suspected coronary artery disease were enrolled in this study. For the stress test, adenosine was injected at 120 μg/kg/min for 6 minutes. Systolic blood pressure, diastolic blood pressure, and heart rate did not show any significant changes after injection of the adenosine and radioisotope (RI) tracer. Adverse events during infusion of the adenosine were seen in 42 (64%) patients and included chest discomfort/oppression in 17 (26%) and dyspnea/throat discomfort in 15 (23%). On the other hand, adverse events just after infusion of the RI tracer occurred in 5 (8%) patients and included chest oppression in 2 (3%) and dyspnea in 1 (2%). Almost all adverse events disappeared quickly without treatment. Therefore, we concluded that adenosine stress myocardial perfusion imaging using a one-route infusion protocol is safe and useful to do for patients unable to secure veins in both arms. (author)

  20. The clinical value of adenosine triphosphate stress myocardial perfusion tomography for detecting coronary artery disease

    International Nuclear Information System (INIS)

    Yao Zhiming; He Qing; Qu Wanying; Yu Xue; Han Lijun; Yu Zhiguo; Li Wei; Zeng Xuezhai; Zhu Ming; Zhao Hongshan

    2002-01-01

    Objective: To study the clinical value of adenosine triphosphate stress myocardial perfusion tomography imaging (ATP-MPI) in detection of coronary artery disease (CAD). Methods: There were 278 patients underwent ATP-MPI, 51 patients of them also underwent coronary angiography (CAG). Seventy-three patients underwent stress-rest myocardial perfusion tomography imaging with multi-stage submaximal exercise test (ST-MPI) and CAG serving as control group. Results: 1) Side effects: there were 11 different symptoms and atrioventricular conduction block (10 patients), sinoatrial conduction block (2 patients) occurred during ATP stress. Allopathy or interruption of ATP stress did not happen. 2) The sensitivity and specificity of ATP-MPI in detection of CAD were 97.1% and 82.4%, respectively, and those in detection of ≥50% narrowing coronary artery were 91.0% and 94.7%, respectively. 3) In patients without myocardial infarction, the sensitivity and specificity of ATP-MPI in detection of myocardial ischemia were comparable to those of ST-MPI. Conclusion: ATP-MPI is an accurate, safe modality and is comparable to ST-MPI in the detection of CAD

  1. Prevalence of symptomatic and silent stress-induced perfusion defects in diabetic patients with suspected coronary artery disease referred for myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Prior, John O.; Calcagni, Maria-Lucia; Bischof Delaloye, Angelika; Monbaron, David; Ruiz, Juan; Koehli, Melanie

    2005-01-01

    Silent myocardial ischaemia - as evaluated by stress-induced perfusion defects on myocardial perfusion scintigraphy (MPS) in patients without a history of chest pain - is frequent in diabetes and is associated with increased rates of cardiovascular events. Its prevalence has been determined in asymptomatic diabetic patients, but remains largely unknown in diabetic patients with suspected coronary artery disease (CAD) in the clinical setting. In this study we therefore sought (a) to determine the prevalence of symptomatic and silent perfusion defects in diabetic patients with suspected CAD and (b) to characterise the eventual predictors of abnormal perfusion. The patient population comprised 133 consecutive diabetic patients with suspected CAD who had been referred for MPS. Studies were performed with exercise (41%) or pharmacological stress testing (1-day protocol, 99m Tc-sestamibi, 201 Tl or both). We used semi-quantitative analysis (20-segment polar maps) to derive the summed stress score (SSS) and the summed difference score (SDS). Abnormal MPS (SSS≥4) was observed in 49 (37%) patients (SSS=4.9±8.4, SDS=2.4±4.7), reversible perfusion defects (SDS≥2) in 40 (30%) patients [SSS=13.3±10.9; SDS=8.0±5.6; 20% moderate to severe (SDS>4), 7% multivessel] and fixed defects in 21 (16%) patients. Results were comparable between patients with and patients without a history of chest pain. Of 75 patients without a history of chest pain, 23 (31%, 95% CI=21-42%) presented reversible defects (SSS=13.9±11.3; SDS=7.4±1.2), indicative of silent ischaemia. Reversible defects were associated with inducible ST segment depression during MPS stress (odds ratio (OR)=3.2, p<0.01). Fixed defects were associated with erectile dysfunction in males (OR=3.7, p=0.02) and lower aspirin use (OR=0.25, p=0.02). Silent stress-induced perfusion defects occurred in 31% of the patients, a rate similar to that in patients with a history of chest pain. MPS could identify these patients with a

  2. Prevalence of symptomatic and silent stress-induced perfusion defects in diabetic patients with suspected coronary artery disease referred for myocardial perfusion scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Prior, John O.; Calcagni, Maria-Lucia; Bischof Delaloye, Angelika [Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Nuclear Medicine, Lausanne (Switzerland); Monbaron, David; Ruiz, Juan [Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Endocrinology, Diabetology and Metabolism, Lausanne (Switzerland); Koehli, Melanie [Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Nuclear Medicine, Lausanne (Switzerland); Centre Hospitalier Universitaire Vaudois (CHUV University Hospital), Division of Endocrinology, Diabetology and Metabolism, Lausanne (Switzerland)

    2005-01-01

    Silent myocardial ischaemia - as evaluated by stress-induced perfusion defects on myocardial perfusion scintigraphy (MPS) in patients without a history of chest pain - is frequent in diabetes and is associated with increased rates of cardiovascular events. Its prevalence has been determined in asymptomatic diabetic patients, but remains largely unknown in diabetic patients with suspected coronary artery disease (CAD) in the clinical setting. In this study we therefore sought (a) to determine the prevalence of symptomatic and silent perfusion defects in diabetic patients with suspected CAD and (b) to characterise the eventual predictors of abnormal perfusion. The patient population comprised 133 consecutive diabetic patients with suspected CAD who had been referred for MPS. Studies were performed with exercise (41%) or pharmacological stress testing (1-day protocol, {sup 99m}Tc-sestamibi, {sup 201}Tl or both). We used semi-quantitative analysis (20-segment polar maps) to derive the summed stress score (SSS) and the summed difference score (SDS). Abnormal MPS (SSS{>=}4) was observed in 49 (37%) patients (SSS=4.9{+-}8.4, SDS=2.4{+-}4.7), reversible perfusion defects (SDS{>=}2) in 40 (30%) patients [SSS=13.3{+-}10.9; SDS=8.0{+-}5.6; 20% moderate to severe (SDS>4), 7% multivessel] and fixed defects in 21 (16%) patients. Results were comparable between patients with and patients without a history of chest pain. Of 75 patients without a history of chest pain, 23 (31%, 95% CI=21-42%) presented reversible defects (SSS=13.9{+-}11.3; SDS=7.4{+-}1.2), indicative of silent ischaemia. Reversible defects were associated with inducible ST segment depression during MPS stress (odds ratio (OR)=3.2, p<0.01). Fixed defects were associated with erectile dysfunction in males (OR=3.7, p=0.02) and lower aspirin use (OR=0.25, p=0.02). Silent stress-induced perfusion defects occurred in 31% of the patients, a rate similar to that in patients with a history of chest pain. MPS could identify

  3. Reproducibility of rest and exercise stress contrast-enhanced calf perfusion magnetic resonance imaging in peripheral arterial disease

    Directory of Open Access Journals (Sweden)

    Jiji Ronny S

    2013-01-01

    Full Text Available Abstract Background The purpose was to determine the reproducibility and utility of rest, exercise, and perfusion reserve (PR measures by contrast-enhanced (CE calf perfusion magnetic resonance imaging (MRI of the calf in normal subjects (NL and patients with peripheral arterial disease (PAD. Methods Eleven PAD patients with claudication (ankle-brachial index 0.67 ±0.14 and 16 age-matched NL underwent symptom-limited CE-MRI using a pedal ergometer. Tissue perfusion and arterial input were measured at rest and peak exercise after injection of 0.1 mM/kg of gadolinium-diethylnetriamine pentaacetic acid (Gd-DTPA. Tissue function (TF and arterial input function (AIF measurements were made from the slope of time-intensity curves in muscle and artery, respectively, and normalized to proton density signal to correct for coil inhomogeneity. Perfusion index (PI = TF/AIF. Perfusion reserve (PR = exercise TF/ rest TF. Intraclass correlation coefficient (ICC was calculated from 11 NL and 10 PAD with repeated MRI on a different day. Results Resting TF was low in NL and PAD (mean ± SD 0.25 ± 0.18 vs 0.35 ± 0.71, p = 0.59 but reproducible (ICC 0.76. Exercise TF was higher in NL than PAD (5.5 ± 3.2 vs. 3.4 ± 1.6, p = 0.04. Perfusion reserve was similar between groups and highly variable (28.6 ± 19.8 vs. 42.6 ± 41.0, p = 0.26. Exercise TF and PI were reproducible measures (ICC 0.63 and 0.60, respectively. Conclusion Although rest measures are reproducible, they are quite low, do not distinguish NL from PAD, and lead to variability in perfusion reserve measures. Exercise TF and PI are the most reproducible MRI perfusion measures in PAD for use in clinical trials.

  4. Perfusion deficits and functional connectivity alterations in patients with post-traumatic stress disorder

    Science.gov (United States)

    Liu, Yang; Li, Baojuan; Zhang, Xi; Zhang, Linchuan; Li, Liang; Lu, Hongbing

    2016-03-01

    To explore the alteration in cerebral blood flow (CBF) and functional connectivity between survivors with recent onset post-traumatic stress disorder (PTSD) and without PTSD, survived from the same coal mine flood disaster. In this study, a processing pipeline using arterial spin labeling (ASL) sequence was proposed. Considering low spatial resolution of ASL sequence, a linear regression method was firstly used to correct the partial volume (PV) effect for better CBF estimation. Then the alterations of CBF between two groups were analyzed using both uncorrected and PV-corrected CBF maps. Based on altered CBF regions detected from the CBF analysis as seed regions, the functional connectivity abnormities in PTSD patients was investigated. The CBF analysis using PV-corrected maps indicates CBF deficits in the bilateral frontal lobe, right superior frontal gyrus and right corpus callosum of PTSD patients, while only right corpus callosum was identified in uncorrected CBF analysis. Furthermore, the regional CBF of the right superior frontal gyrus exhibits significantly negative correlation with the symptom severity in PTSD patients. The resting-state functional connectivity indicates increased connectivity between left frontal lobe and right parietal lobe. These results indicate that PV-corrected CBF exhibits more subtle perfusion changes and may benefit further perfusion and connectivity analysis. The symptom-specific perfusion deficits and aberrant connectivity in above memory-related regions may be putative biomarkers for recent onset PTSD induced by a single prolonged trauma exposure and help predict the severity of PTSD.

  5. Measurement of extracellular volume and transit time heterogeneity using contrast-enhanced myocardial perfusion MRI in patients after acute myocardial infarction.

    Science.gov (United States)

    Kunze, Karl P; Rischpler, Christoph; Hayes, Carmel; Ibrahim, Tareq; Laugwitz, Karl-Ludwig; Haase, Axel; Schwaiger, Markus; Nekolla, Stephan G

    2017-06-01

    To assess the ability of dynamic contrast-enhanced myocardial perfusion MRI to measure extracellular volume (ECV) and to investigate the possibility of estimating capillary transit time heterogeneity (CTH) in patients after myocardial infarction and successful revascularization. Twenty-four perfusion data sets were acquired on a 3 Tesla positron emission tomography (PET)/MRI scanner. Three perfusion models of different complexity were implemented in a hierarchical fashion with an Akaike information criterion being used to determine the number of fit parameters supported by the data. Results were compared sector-wise to ECV from an equilibrium T 1 mapping method (modified look-locker inversion recovery (MOLLI)). ECV derived from the perfusion analysis correlated well with equilibrium measurements (R² = 0.76). Estimation of CTH was supported in 16% of sectors (mostly remote). Inclusion of a nonzero CTH parameter usually led to lower estimates of first-pass extraction and slightly higher estimates of blood volume and flow. Estimation of the capillary permeability-surface area product was feasible in 81% of sectors. Transit time heterogeneity has a measurable effect on the kinetic analysis of myocardial perfusion MRI data, and Gd-DTPA extravasation in the myocardium is usually not flow-limited in infarct-related pathology. Measurement of myocardial ECV using perfusion imaging could provide a scan-time efficient alternative to methods based on T 1 mapping. Magn Reson Med 77:2320-2330, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  6. Relationship between stress ankle radiographs and injured ligaments on MRI

    International Nuclear Information System (INIS)

    Lee, Kyoung Min; Chung, Chin Youb; Chung, Myung Ki; Won, Sung Hun; Lee, Seung Yeol; Park, Moon Seok; Kwon, Soon-Sun

    2013-01-01

    This study was performed to investigate the relationship between the injured lateral ankle ligaments on MRI and stress ankle radiographs. Two hundred and twenty-nine consecutive patients (mean age 35.5 years, SD 14.6 years; 136 males and 93 females) that underwent ankle stress radiographs and MRI for lateral ankle instability were included. Tibiotalar tilt angle and anterior translation of talus were measured on stress ankle radiographs. Degree of lateral ligaments (anterior talofibular, calcaneofibular, and posterior talofibular) and deltoid ligament injuries were evaluated and scored as intact (0), partial injury (1), and complete injury (2) on MR images. Effusion of ankle joint was also recorded. The effects of gender, age, injuries of ligaments, and ankle joint effusion on stress radiographs were statistically analyzed. Gender (p = 0.010), age (p = 0.020), and anterior talofibular ligament (ATFL) injury (p < 0.001) were the factors significantly affecting tibiotalar tilt angle. Posterior talofibular ligament (PTFL) injury (p = 0.014) was found to be the only significant factor affecting the anterior translation on the anterior drawer radiographs. ATFL injury and PTFL injury on MRI significantly affected tibiotalar tilt angle and anterior drawer on stress radiographs. Other factors, such as age and gender, need to be considered in evaluating radiographic lateral ankle instability. (orig.)

  7. Can Stress Echocardiography Compete with Perfusion Scintigraphy in the Detection of Coronary Artery Disease and Cardiac Risk Assessment?

    NARCIS (Netherlands)

    M.L. Geleijnse (Marcel); A. Elhendy (Abdou)

    2000-01-01

    textabstractAims: The aim of this review was to define the place of stress echocardiography in the context of perfusion scintigraphy for the detection of coronary artery disease (CAD) and the assessment of cardiac risk. Stress echocardiography has the benefits of widespread availability, relatively

  8. Simultaneous assessment of myocardial perfusion and function during mental stress in patients with chronic coronary artery disease.

    Science.gov (United States)

    Arrighi, James A; Burg, Matthew; Cohen, Ira S; Soufer, Robert

    2003-01-01

    Mental stress (MS) is an important provocateur of myocardial ischemia in many patients with chronic coronary artery disease. The majority of laboratory assessments of ischemia in response to MS have included measurements of either myocardial perfusion or function alone. We performed this study to determine the relationship between alterations in perfusion and ventricular function during MS. Methods and results Twenty-eight patients with reversible perfusion defects on exercise or pharmacologic stress myocardial perfusion imaging (MPI) underwent simultaneous technetium 99m sestamibi single photon emission computed tomography (SPECT) MPI and transthoracic echocardiography at rest and during MS according to a mental arithmetic protocol. In all cases the MS study was performed within 4 weeks of the initial exercise or pharmacologic MPI that demonstrated ischemia. SPECT studies were analyzed visually with the use of a 13-segment model and quantitatively by semiautomated circumferential profile analysis. Echocardiograms were graded on a segmental model for regional wall motion on a 4-point scale. Of 28 patients, 18 (64%) had perfusion defects and/or left ventricular dysfunction develop during MS: 9 (32%) had myocardial perfusion defects develop, 6 (21%) had regional or global left ventricular dysfunction develop, and 3 (11%) had both perfusion defects and left ventricular dysfunction develop. The overall concordance between perfusion and function criteria for ischemia during MS was only 46%. Among 9 patients with MS-induced left ventricular dysfunction, 5 had new regional wall motion abnormalities and 4 had a global decrement in function. In patients with MS-induced ischemia by SPECT, the number of reversible perfusion defects was similar during both MS and exercise/pharmacologic stress (2.8 +/- 2.0 vs 3.5 +/- 1.8, P =.41). Hemodynamic changes during MS were similar whether patients were divided on the basis of perfusion defects or left ventricular dysfunction during MS

  9. Impact of chronic kidney disease and stress myocardial perfusion imaging as a predictor of cardiovascular events

    International Nuclear Information System (INIS)

    Furuhashi, Tatsuhiko; Joki, Nobuhiko; Hase, Hiroki; Masai, Hirofumi; Kunimasa, Taeko; Nakazato, Ryo; Fukuda, Hiroshi; Sugi, Kaoru; Moroi, Masao

    2011-01-01

    Stress myocardial perfusion imaging (MPI) is an established means of predicting cardiovascular events and is suitable in chronic kidney disease (CKD) patients. We aimed to evaluate the prognostic value of CKD parameters and an abnormal stress MPI for cardiovascular events. A total of 495 patients with suspected coronary artery disease (CAD) or history of CAD including 130 CKD patients not undergoing hemodialysis, underwent stress MPI (313 males, mean age 70 years) and were followed up for 14 months (mean period). CKD was defined as an estimated GFR of 2 and/or persistent proteinuria. Cardiovascular events were defined as sudden cardiac death, acute coronary syndrome and congestive heart failure requiring hospitalization. Cardiovascular events occurred in 41 (8.3%) patients. Multivariate Cox regression analysis indicated that CKD [hazard ratio (HR) =3.76, p<0.001] and a stress MPI summed difference score (SDS) of ≥2 (HR=3.78, p<0.001) were independent predictors of cardiovascular events; CKD plus abnormal stress MPI was also a strong predictor of cardiovascular events (non-CKD and SDS <2 vs. CKD and SDS ≥2, HR=15.9, p<0.001). Both CKD and myocardial ischemia detected by stress MPI are independent predictors for cardiovascular events. Coexistence of CKD and myocardial ischemia detected by stress MPI is more useful for short-term risk stratification of cardiovascular events. (author)

  10. MRI in acute cerebral ischaemia: perfusion imaging with superparamagnetic iron oxide in a rat model

    International Nuclear Information System (INIS)

    Forsting, M.; Reith, W.; Doerfler, A.; Kummer, R. von; Hacke, W.; Sartor, K.

    1994-01-01

    An imaging technique capable of detecting ischaemic cerebral injury at an early stage could improve diagnosis in acute or transient cerebral ischaemia. We compared the ability of superparamagnetically contrast-enhanced MRI and conventional T2-weighted MRI to detect ischaemic injury early after unilateral occlusion of the middle cerebral artery in 12 male Wistar rats. Permanent vessel occlusion was achieved by a transvascular approach, which has the advantage of not requiring a craniectom. At 45-60 min after the procedure, the animals had conventional T2-weighted MRI before and after administration of a superparamagnetic contrast agent (iron oxide particles). Unenhanced images were normal in all animals. After administration of iron oxide particles, the presumed ischaemic area was clearly visible, as relatively increased signal, in all animals; this high signal area corresponded to the area of ischaemic brain infarction seen on histological studies. Our results suggest that superparamagnetic iron particles may significantly reduce the interval between an ischaemic insult and the appearance of parenchymal changes on MRI. (orig./UWA)

  11. Diagnostic value of rest and stress gated 82Rb PET myocardial perfusion imaging using quantitative software

    International Nuclear Information System (INIS)

    Shi Hongcheng; Gu Yusen; Liu Wenguan; Zhu Weimin; Halkar, R.K.; Santana, C.A.; Feng Yusheng

    2008-01-01

    Objective: Gated myocardial perfusion imaging (MPI) is regularly performed using SPECT. More recently, gated 82 Rb MPI has been used to assess left ventricular myocardial perfusion and function with new generation PET scanners. The objective of this study was to evaluate the value of rest and stress gated 82 Rb PET myocardial perfusion imaging and to determine whether the quantitative technique in- creased the confidence level of the interpreters. Methods: Thirty-two patients underwent rest and adenosine stress gated 82 Pb PET MPI. Emory Cardiac Toolbox quantitative software was used for processing and inter-predation. Left ventricular ejection fraction (LVEF), end-diastolic, end-systolic and transient ischemia dilation ratio were automatically generated. Three interpreters (nuclear medicine doctors) independently reviewed the studies. Visual scoring (1-5 scales: excellent, good, unsure, poor, uninterpretable) was used to assess the overall quality of the gated images and the added confidence level of interpretation. Visual assessment of the LVEF was compared to the automatically generated LVEF. Comparison between the visual assessment and software generated was graded on a 1- 5 scales (helpful, probably helpful, unsure, probably not helpful, definitely not helpful). The analysed items were divided into two groups (favorable group and negative group). The percentage and 95% confidence intervals of each group were calculated. Results: A total of 192 gated studies were evaluated (64 gated x 3 interpreters ). The overall quality of the gated images was good [excellent 40.1% (77/192), good 43.2% (83/192), unsure 3.1% (6/192), poor 13.6% (26/192), uninterpretable 0]. The 95% confidence intervals of good and excellent quality range from 78.1% to 88.6%. The interpreter's agreed with the automated LVEF on 85.4% of the gated images [agree 76.6% (147/192), probably agree 8.8% (17/192), unsure 3.1% (6/192), probably disagree 8.8% (17/192), disagree 2.6% (5/192)]. And its 95

  12. Toward fully automated processing of dynamic susceptibility contrast perfusion MRI for acute ischemic cerebral stroke.

    Science.gov (United States)

    Kim, Jinsuh; Leira, Enrique C; Callison, Richard C; Ludwig, Bryan; Moritani, Toshio; Magnotta, Vincent A; Madsen, Mark T

    2010-05-01

    We developed fully automated software for dynamic susceptibility contrast (DSC) MR perfusion-weighted imaging (PWI) to efficiently and reliably derive critical hemodynamic information for acute stroke treatment decisions. Brain MR PWI was performed in 80 consecutive patients with acute nonlacunar ischemic stroke within 24h after onset of symptom from January 2008 to August 2009. These studies were automatically processed to generate hemodynamic parameters that included cerebral blood flow and cerebral blood volume, and the mean transit time (MTT). To develop reliable software for PWI analysis, we used computationally robust algorithms including the piecewise continuous regression method to determine bolus arrival time (BAT), log-linear curve fitting, arrival time independent deconvolution method and sophisticated motion correction methods. An optimal arterial input function (AIF) search algorithm using a new artery-likelihood metric was also developed. Anatomical locations of the automatically determined AIF were reviewed and validated. The automatically computed BAT values were statistically compared with estimated BAT by a single observer. In addition, gamma-variate curve-fitting errors of AIF and inter-subject variability of AIFs were analyzed. Lastly, two observes independently assessed the quality and area of hypoperfusion mismatched with restricted diffusion area from motion corrected MTT maps and compared that with time-to-peak (TTP) maps using the standard approach. The AIF was identified within an arterial branch and enhanced areas of perfusion deficit were visualized in all evaluated cases. Total processing time was 10.9+/-2.5s (mean+/-s.d.) without motion correction and 267+/-80s (mean+/-s.d.) with motion correction on a standard personal computer. The MTT map produced with our software adequately estimated brain areas with perfusion deficit and was significantly less affected by random noise of the PWI when compared with the TTP map. Results of image

  13. MRI evaluation of cerebral perfusion changes in patients with MELAS syndrome

    International Nuclear Information System (INIS)

    Xie Sheng; Qi Zhaoyue; Xiao Jiangxi; Jiang Xuexiang; Yang Yanling

    2008-01-01

    Objective: To detect the changes of cerebral perfusion in patients with MELAS syndrome by using MR perfusion technique. Methods: Thirteen patients with MELAS syndrome and 13 controls with normal neurological conditions were scanned with the sequence of flow-sensitive alternating inversion recovery exempting separate T 1 measurement (FAIREST). Their rCBF values were obtained in regions of bilateral basilar nuclei and thalami, as well as bilateral temporal lobes and occipital lobes. Regression analysis was carried out to determine the effect of location and side on the measurement of rCBF in controls. One-way ANOVA was conducted to compare rCBF values among the control group, the lesion ROIs and normal ROIs of the MELAS syndrome group. Results: The values of rCBF were 0.83 ± 0.23, 1.17± 0.30, 0.93 ± 0.28, and 1.11 ± 0.25 for the left basilar ganglia, thalamus, temporal lobe, and occipital lobe respectively, while they were 0.77 ± 0.15, 1.03 ± 0.34, 1.06 ± 0.23, and 1.09 ± 0.23 for the right basilar ganglia, thalamus, temporal lobe, and occipital lobe respectively. Regression analysis revealed no effect of location and side on the rCBF (P>0.05). The rCBF value for control group was 1.00 + 0. 28, while it was 1.01 ± 0.31 for the normal ROIs and 1.95 ± 0.43 for the lesion ROIs in the MELAS syndrome group (F=54.99, P<0.01). The rCBF of the lesion ROIs in the MELAS syndrome group was significantly higher than the normal ROIs and the control group. Conclusion: CBF maps can reveal changes of cerebral blood flow in patients with ictal MELAS, which suggests increased perfusion in the stroke-like lesions. (authors)

  14. Prognostic value of stress 99Tcm-MIBI myocardial perfusion SPECT after acute myocardial infarction

    International Nuclear Information System (INIS)

    Sui Xutao; Chen Zhi; Gao Shenghai; Shen Li; Li Shang'ai

    2003-01-01

    Objective: To investigate relativity of acute myocardial infarction (AMI) with clinical, stress test and perfusion imaging parameters and to assess predictive value on hard events of cardiac death or recurrent nonfatal AMI. Methods: One hundred and one patients of AMI underwent stress 99 Tc m -MIBI SPECT before discharge. Hard and soft events were followed-up, relative factors with cardiac events were analyzed by statistical methods and predictive value on hard events were assessed. Results: Independent predictors by multivariate analysis for cardiac hard events or all cardiac events consisted of a history of prior AMI (RR=5.30, CI 2.17-12.98), a low exercise capacity (RR=6.28, CI 1.92-21.46) and left ventricular ejection fraction 99 Tc m -MIBI SPECT is a single test that can provide exercise parameter, cardiac perfusion imaging information and left ventricular function assessment to identify high-risk and estimate hard prognosis at discharge of AMI patients. These high-risk patients can be referred for early invasive evaluation and intervention

  15. Diagnostic and clinical benefit of combined coronary calcium and perfusion assessment in patients undergoing PET/CT myocardial perfusion stress imaging.

    Science.gov (United States)

    Bybee, Kevin A; Lee, John; Markiewicz, Richard; Longmore, Ryan; McGhie, A Iain; O'Keefe, James H; Hsu, Bai-Ling; Kennedy, Kevin; Thompson, Randall C; Bateman, Timothy M

    2010-04-01

    A limitation of stress myocardial perfusion imaging (MPI) is the inability to detect non-obstructive coronary artery disease (CAD). One advantage of MPI with a hybrid CT device is the ability to obtain same-setting measurement of the coronary artery calcium score (CACS). Utilizing our single-center nuclear database, we identified 760 consecutive patients with: (1) no CAD history; (2) a normal clinically indicated Rb-82 PET/CT stress perfusion study; and (3) a same-setting CAC scan. 487 of 760 patients (64.1%) had subclinical CAD based on an abnormal CACS. Of those with CAC, the CACS was > or =100, > or =400, and > or =1000 in 47.0%, 22.4%, and 8.4% of patients, respectively. Less than half of the patients with CAC were receiving aspirin or statin medications prior to PET/CT imaging. Patients with CAC were more likely to be initiated or optimized on proven medical therapy for CAD immediately following PET/CT MPI compared to those without CAC. Subclinical CAD is common in patients without known CAD and normal myocardial perfusion assessed by hybrid PET/CT imaging. Identification of CAC influences subsequent physician prescribing patterns such that those with CAC are more likely to be treated with proven medical therapy for the treatment of CAD.

  16. Characterization of glial tumors in PET/CT 18F-dopa and in perfusion MRI

    International Nuclear Information System (INIS)

    Nioche, Christophe

    2011-01-01

    MRI provides morphological information about a tumour, as well as information regarding its micro-vascularisation of the tumour. In PET/CT, accumulation of 18 F-Dopa in tumour cells results from the metabolic activity greater than that of healthy tissues.We studied 28 gliomas for which we analysed data from MRI and PET/CT. A registration method has been developed to combine information from both PET and MRI and to extract volumes of interest consistent with the information included in the two modalities. In these volumes, the tumour compartment and normal tissue compartment were identified using a Gaussian mixture model. Parameters from PET or MRI data were then calculated in these compartments. ROC analyses combined with linear discriminant analyses were used to assess whether joint observation of standardized uptake value (SUVmax) and relative Cerebral Blood Volume (rCBV) or of relative rk1 and rCBV could distinguish between low grade and high grade tumours. We found that using this joint analysis, 82% of high-grade tumors and 70% of low grade tumors were correctly classified (AUC of 0.88 for [SUVmax, rCBV] and of 0.92 for [rk1, rCBV]). Considering the combined information from [SUVmax, rCBV], the sensitivity for detecting high-grade tumors was 95% with a specificity of 60%. The negative predictive value was 52% for a positive predictive value of 95%. Similarly, considering the combined information from [rk1, rCBV], we also obtain a specificity of 60% associated with a 95% sensitivity for detecting high-grade tumors, with a negative predictive value of 60% and positive predictive value of 95%. Our work shows that joint analysis of information from microvascular and metabolic is possible by combining PET and MR imaging data. However, we found that, in our patient population, the microvascular information obtained through MR did not achieve better discrimination than the metabolic information derived from PET only. (author)

  17. Longitudinal MRI study of cortical thickness, perfusion, and metabolite levels in major depressive disorder

    DEFF Research Database (Denmark)

    Järnum, Hanna; Eskildsen, Simon Fristed; Steffensen, Elena G

    2011-01-01

    OBJECTIVE: To determine whether patients with major depressive disorder (MDD) display morphologic, functional, and metabolic brain abnormalities in limbic-cortical regions at a baseline magnetic resonance (MR) scan and whether these changes are normalized in MDD patients in remission at a follow......-acetylaspartate, myo-inositol, and glutamate levels in MDD patients compared with healthy controls at baseline. CONCLUSION: Using novel MRI techniques, we have found abnormalities in cerebral regions related to cortical-limbic pathways in MDD patients....

  18. Prevalence and predictors of an abnormal stress myocardial perfusion study in asymptomatic patients with type 2 diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Scholte, Arthur J.H.A.; Schuijf, Joanne D.; Wall, Ernst E. van der; Bax, Jeroen J. [Leiden University Medical Center, Department of Cardiology, Albinusdreef 2, PO Box 9600, Leiden (Netherlands); Kharagjitsingh, Antje V. [Medisch Centrum Haaglanden, Department of Internal Medicine, The Hague (Netherlands); Dibbets-Schneider, Petra; Stokkel, Marcel P. [Leiden University Medical Center, Department of Nuclear Medicine, Leiden (Netherlands)

    2009-04-15

    The purpose of this study was to evaluate the prevalence of an abnormal stress myocardial perfusion study in a cohort of truly asymptomatic patients with type 2 diabetes mellitus using myocardial perfusion imaging by means of single photon emission computed tomography (SPECT). Secondly, we determined which clinical characteristics may predict an abnormal stress myocardial perfusion study in this population. A total of 120 asymptomatic patients (mean age 53{+-}10 years) with type 2 diabetes mellitus and one or more risk factors for coronary artery disease were prospectively recruited from an outpatient diabetes clinic. All patients underwent myocardial perfusion imaging by means of adenosine {sup 99m}Tc sestamibi SPECT. Images were evaluated for the presence of perfusion abnormalities as well as other nonperfusion abnormalities that may indicate extensive ischaemia, including left ventricular dysfunction (defined as a left ventricular ejection fraction <45%), transient ischaemic dilatation and adenosine-induced ST segment depression. Multivariable analysis was performed using a backward selection strategy to identify potential predictors for an abnormal stress myocardial perfusion study. Finally, all patients were followed up for 12 months to determine the occurrence of cardiovascular events: (1) cardiac death, (2) nonfatal myocardial infarction, (3) unstable angina requiring hospitalization, (4) revascularization, or (5) stroke. Of the 120 patients, 40 (33%) had an abnormal stress study, including myocardial perfusion abnormalities in 30 patients (25%). In 10 patients (8%), indicators of extensive (possibly balanced ischaemia) were observed in the absence of abnormal perfusion. The multivariable analysis identified current smoking, duration of diabetes and the cholesterol/high-density lipoprotein (HDL) ratio as independent predictors of an abnormal stress study. During a follow-up period of 12 months six patients (5%) had a cardiovascular event. The current study

  19. Perfusion MRI abnormalities in the absence of diffusion changes in a case of moyamoya-like syndrome in neurofibromatosis type 1

    International Nuclear Information System (INIS)

    El-Koussy, Marwan; Kiefer, Claus; Schroth, Gerhard; Loevblad, Karl-Olof; Steinlin, Maja

    2002-01-01

    We report on a 12-year-old boy with neurofibromatosis type 1 who suffered a transient ischemic attack. Angiography revealed occlusion of intracranial arteries, moyamoya vessels and leptomeningeal collaterals. The conventional T2-weighted and the diffusion-weighted MRI images demonstrated no pathology. Dynamic first-pass postgadolinium T2* perfusion-weighted MRI depicted altered hemodynamics in the vascular territory of the left middle cerebral artery, which defined this region as ischemic tissue at risk. The patient suffered a repeat transient ischemic attack5 days later. (orig.)

  20. Low-dose dobutamine stress gated SPET for identification of viable myocardium: comparison with stress-rest perfusion SPET and PET

    International Nuclear Information System (INIS)

    Yoshinaga, Keiichiro; Tamaki, Nagara; Katoh, Chietsugu; Kuge, Yuji; Noriyasu, Kazuyuki; Yamada, Satoshi; Ito, Yoshinori; Kohya, Tetsuro; Kitabatake, Akira; Kawai, Yuko

    2002-01-01

    The detection of viable myocardium is important for the prediction of functional recovery after revascularisation. However, a fixed perfusion defect often includes viable myocardium, and perfusion imaging then underestimates myocardial viability. We previously reported that low-dose dobutamine stress gated single-photon emission tomography (SPET) provides similar findings to dobutamine stress echocardiography in the assessment of myocardial viability. The present study investigated whether low-dose dobutamine stress gated SPET is of additional value as compared with stress-rest technetium-99m tetrofosmin SPET for the detection of myocardial viability. Standard stress-rest perfusion SPET, low-dose dobutamine stress gated SPET and fluorine-18 fluorodeoxyglucose positron emission tomography (FDG PET) were studied in 23 patients (mean age 67±7.6 years) with previous myocardial infarction. Twenty-one of them were successfully studied with each technique. FDG PET viability (FDG uptake ≥50%) was employed as the gold standard. One-day stress-rest 99m Tc-tetrofosmin myocardial SPET was performed. After the resting study, gated SPET was acquired following infusion of 7.5 μg kg -1 min -1 of dobutamine. Left ventricular wall motion in 16 segments was assessed by cine mode display using a four-point scale. Myocardial viability was considered present when there was improvement by one point. Of a total of 336 segments analysed, 53 had persistent defects on stress-rest perfusion SPET. FDG viability was seen in 16 of 17 dobutamine-responsive segments, but in only 11 of 36 dobutamine non-responsive segments (P<0.01). Thus, in the segments with persistent defects, viability findings on low-dose dobutamine stress gated SPET were concordant with those on FDG PET in 77% of segments (kappa value =0.55). For the detection of FDG-viable myocardium, the combination of stress-rest perfusion SPET and low-dose dobutamine stress gated SPET achieved a better sensitivity than stress

  1. Scintigraphic assessment of normal values of lower limb perfusion under stress and rest, with possible clinical applications

    International Nuclear Information System (INIS)

    Malkowski, B.; Zajac, A.; Maziarz, Z.; Zaborowski, G.; Ryglewska-Brzozowska, M.; Malara, A.; Tryniszewski, W.

    2005-01-01

    The lack of a range of normal values of perfusion in the lower limbs during stress and at rest narrows the use of this type of diagnostic tool to the estimation of the current state of relative perfusion without indications of the presence or level of perfusion disturbances. Numerous reports on early changes in endothelium reactivity (depending on disease and degree of vessel pathology) encouraged us to assess lower limb perfusion in healthy people. Our goal was to 1) work out a program and method which would enable lower limb perfusion assessment under stress and at rest in patients without signs of lower limb circulation deprivation and 2) establish the normal range of indexes of lower limb perfusion under stress and at rest which would enable their use in the diagnostics of lower limb muscle circulation. 33 male patients aged between 25 to 45 years (mean: 35.30 ± 6.04) without signs of circulatory problems were entered into the study. To exclude circulatory disturbances, Doppler USG, blood pressure, and laboratory tests were performed on every patient at rest 5 min. after the injection of 11.1 MBq/kg 99 mTc MIBI. Whole body as well as thigh and calf scintigrams were made with an ELSCINT SP6HR gamma-camera. The symmetry of the thigh and calf perfusion (WSU, WSP) and the indexes of the thigh (WPLU, WPPU) and calf (WPLP, WSPP) perfusion of both lower limbs were estimated. At rest: WSP: 96.47% ±1.02, WSP: 96.47% ± 1.02, WPLP: 9.77 ± 0.32, WPPP: 9.78 ± 0.31, WPLU: 8.45 ± 0.22, WPPU: 8.48 ± 0.22. Under stress: WSP: 96.69% ± 1.32, WSU: 96.41% ± 1.20, WPLP: 8.78 ± 0.26, WPPP: 8.81 ± 0.25, WPLU: 7.77 ± 0.25, WPPU: 7.82 ± 0.26. Anamnesis, additional studies, and laboratory tests in the group examined did not show any circulatory disturbances. The estimated values in patients without circulatory disturbances are similar and within a narrow range, which allows us to calculate the norms of lower limb perfusion at rest and under stress. The determined normal

  2. Response Assessment in Neuro-Oncology criteria, contrast enhancement and perfusion MRI for assessing progression in glioblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Tensaouti, Fatima [Universite de Toulouse, Inserm, UPS, ToNIC, Toulouse NeuroImaging Center, Toulouse (France); Khalifa, Jonathan [Claudius Regaud Institute / Toulouse University Cancer Institute - Oncopole, Department of Radiation Oncology, Toulouse (France); Lusque, Amelie [Claudius Regaud Institute / Toulouse University Cancer Institute - Oncopole, Department of Biostatistics, Toulouse (France); Plas, Benjamin [CHU Toulouse, Department of Neurosurgery, Toulouse (France); Lotterie, Jean Albert; Berry, Isabelle [Universite de Toulouse, Inserm, UPS, ToNIC, Toulouse NeuroImaging Center, Toulouse (France); CHU Toulouse, Department of Nuclear Medicine, Toulouse (France); Laprie, Anne [Universite de Toulouse, Inserm, UPS, ToNIC, Toulouse NeuroImaging Center, Toulouse (France); Claudius Regaud Institute / Toulouse University Cancer Institute - Oncopole, Department of Radiation Oncology, Toulouse (France); Cohen-Jonathan Moyal, Elizabeth [Claudius Regaud Institute / Toulouse University Cancer Institute - Oncopole, Department of Radiation Oncology, Toulouse (France); Toulouse Center for Cancer Research (U1037), Inserm, Toulouse (France); Lubrano, Vincent [Universite de Toulouse, Inserm, UPS, ToNIC, Toulouse NeuroImaging Center, Toulouse (France); CHU Toulouse, Department of Neurosurgery, Toulouse (France)

    2017-10-15

    The purpose of the study was to evaluate Response Assessment in Neuro-Oncology (RANO) criteria in glioblastoma multiforme (GBM), with respect to the Macdonald criteria and changes in contrast-enhancement (CE) volume. Related variations in relative cerebral blood volume (rCBV) were investigated. Forty-three patients diagnosed between 2006 and 2010 were included. All underwent surgical resection, followed by temozolomide-based chemoradiation. MR images were retrospectively reviewed. Times to progression (TTPs) according to RANO criteria, Macdonald criteria and increased CE volume (CE-3D) were compared, and the percentage change in the 75th percentile of rCBV (rCBV75) was evaluated. After a median follow-up of 22.7 months, a total of 39 patients had progressed according to RANO criteria, 32 according to CE-3D, and 42 according to Macdonald. Median TTPs were 6.4, 9.3, and 6.6 months, respectively. Overall agreement was 79.07% between RANO and CE-3D and 93.02% between RANO and Macdonald. The mean percentage change in rCBV75 at RANO progression onset was over 73% in 87.5% of patients. In conclusion, our findings suggest that CE-3D criterion is not yet suitable to assess progression in routine clinical practice. Indeed, the accurate threshold is still not well defined. To date, in our opinion, early detection of disease progression by RANO combined with advanced MRI imaging techniques like MRI perfusion and diffusion remains the best way to assess disease progression. Further investigations that would examine the impact of treatment modifications after progression determined by different criteria on overall survival would be of great value. (orig.)

  3. Response Assessment in Neuro-Oncology criteria, contrast enhancement and perfusion MRI for assessing progression in glioblastoma

    International Nuclear Information System (INIS)

    Tensaouti, Fatima; Khalifa, Jonathan; Lusque, Amelie; Plas, Benjamin; Lotterie, Jean Albert; Berry, Isabelle; Laprie, Anne; Cohen-Jonathan Moyal, Elizabeth; Lubrano, Vincent

    2017-01-01

    The purpose of the study was to evaluate Response Assessment in Neuro-Oncology (RANO) criteria in glioblastoma multiforme (GBM), with respect to the Macdonald criteria and changes in contrast-enhancement (CE) volume. Related variations in relative cerebral blood volume (rCBV) were investigated. Forty-three patients diagnosed between 2006 and 2010 were included. All underwent surgical resection, followed by temozolomide-based chemoradiation. MR images were retrospectively reviewed. Times to progression (TTPs) according to RANO criteria, Macdonald criteria and increased CE volume (CE-3D) were compared, and the percentage change in the 75th percentile of rCBV (rCBV75) was evaluated. After a median follow-up of 22.7 months, a total of 39 patients had progressed according to RANO criteria, 32 according to CE-3D, and 42 according to Macdonald. Median TTPs were 6.4, 9.3, and 6.6 months, respectively. Overall agreement was 79.07% between RANO and CE-3D and 93.02% between RANO and Macdonald. The mean percentage change in rCBV75 at RANO progression onset was over 73% in 87.5% of patients. In conclusion, our findings suggest that CE-3D criterion is not yet suitable to assess progression in routine clinical practice. Indeed, the accurate threshold is still not well defined. To date, in our opinion, early detection of disease progression by RANO combined with advanced MRI imaging techniques like MRI perfusion and diffusion remains the best way to assess disease progression. Further investigations that would examine the impact of treatment modifications after progression determined by different criteria on overall survival would be of great value. (orig.)

  4. Functional improvement after carotid endarterectomy: demonstrated by gait analysis and acetazolamide stress brain perfusion SPECT

    International Nuclear Information System (INIS)

    Kim, J. S.; Kim, G. E.; Yoo, J. Y.; Kim, D. G.; Moon, D. H.

    2005-01-01

    Scientific documentation of neurologic improvement following carotid endarterectomy (CEA) has not been established. The purpose of this prospective study is to investigate whether CEA performed for the internal carotid artery flow lesion improves gait and cerebrovascular hemodynamic status in patients with gait disturbance. We prospectively performed pre- and postCEA gait analysis and acetazolamide stress brain perfusion SPECT (Acz-SPECT) with Tc-99m ECD in 91 patients (M/F: 81/10, mean age: 64.1 y) who had gait disturbance before receiving CEA. Gait performance was assessed using a Vicon 370 motion analyzer. The gait improvement after CEA was correlated to cerebrovascular hemodynamic change as well as symptom duration. 12 hemiparetic stroke patients (M/F=9/3, mean age: 51 y) who did not receive CEA as a control underwent gait analysis twice in a week interval to evaluate whether repeat testing of gait performance shows learning effect. Of 91 patients, 73 (80%) patients showed gait improvement (change of gait speed > 10%) and 42 (46%) showed marked improvement (change of gait speed > 20%), but no improvement was observed in control group at repeat test. Post-operative cerebrovascular hemodynamic improvement was noted in 49 (54%) of 91 patients. There was marked gait improvement in patients group with cerebrovascular hemodynamic improvement compared to no change group (p<0.05). Marked gait improvement and cerebrovascular hemodynamic improvement were noted in 53% and 61% of the patient who had less than 3 month history of symptom compared to 31% and 24% of the patients who had longer than 3 months, respectively (p<0.05). Marked gait improvement was obtained in patients who had improvement of cerebrovascular hemodynamic status on Acz-SPECT after CEA. These results suggest functional improvement such as gait can result from the improved perfusion of misery perfusion area, which is viable for a longer period compared to literatures previously reported

  5. Morphological and functional MRI, MRS, perfusion and diffusion changes after radiosurgery of brain metastasis

    International Nuclear Information System (INIS)

    Kang, Tae Wook; Kim, Sung Tae; Byun, Hong Sik; Jeon, Pyoung; Kim, Keonha; Kim, Hyungjin; Lee, Jung II

    2009-01-01

    Radiosurgery is a noninvasive procedure where spatially accurate and highly conformal doses of radiation are targeted at brain lesions with an ablative intent. Recently, radiosurgery has been established as an effective technique for local treatment of brain metastasis. After radiosurgery, magnetic resonance (MR) imaging plays an important role in the assessment of the therapeutic response and of any complications. The therapeutic approach depends on the imaging findings obtained after radiosurgery, which have a role in the decision making to perform additional invasive modalities (repeat resection, biopsy) to obtain a definite diagnosis and to improve the survival of patients. Conventional MR imaging findings are mainly based on morphological alterations of tumors. However, there are variable imaging findings of radiation-induced changes including radiation necrosis in the brain. Radiologists are sometimes confused by radiation-induced injuries, including radiation necrosis, that are seen on conventional MR imaging. The pattern of abnormal enhancement on follow-up conventional MR imaging closely mimics that of a recurrent brain metastasis. So, classifying newly developed abnormal enhancing lesions in follow-up of treated brain metastasis with correct diagnosis is one of the key goals in neuro-oncologic imaging. To overcome limitations of the use of morphology-based conventional MR imaging, several physiological-based functional MR imaging methods have been used, namely diffusion-weighted imaging, perfusion MR imaging, and proton MR spectroscopy, for the detection of hemodynamic, metabolic, and cellular alterations. These imaging modalities provide additional information to allow clinicians to make proper decisions regarding patient treatment.

  6. Functional MRI procedures in the diagnosis of brain tumors. Perfusion- and diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Hartmann, M.; Heiland, S.; Sartor, K.

    2002-01-01

    Despite the increased diagnostic accuracy of contrast material enhanced MR imaging, specification and grading of brain tumors are still only approximate at best: neither morphology, nor relaxation times or contrast material enhancement reliably predict tumor histology or tumor grade. As histology and tumor grade strongly influence which therapy concept is chosen, a more precise diagnosis is mandatory. With diffusion- and perfusion-weighted MR imaging (DWI, PWI) it is now possible to obtain important information regarding the cellular matrix and the relative regional cerebral blood volume (rrCBV) of brain tumors, which cannot be obtained with standard MR techniques. These dynamic-functional imaging techniques are very useful in the preoperative diagnosis of gliomas, lymphomas, and metastases, as well as in the differentiation of these neoplastic lesions from abscesses, atypical ischemic infarctions, and tumor-like manifestations of demyelinating disease. Additionally, they appear suitable for determining glioma grade and regions of active tumor growth which should be the target of stereotactic biopsy and therapy. After therapy these techniques are helpful to better assess the tumor response to therapy, possible therapy failure and therapy complications such as radiation necrosis. (orig.) [de

  7. DCE-MRI of hepatocellular carcinoma: perfusion quantification with Tofts model versus shutter-speed model--initial experience.

    Science.gov (United States)

    Jajamovich, Guido H; Huang, Wei; Besa, Cecilia; Li, Xin; Afzal, Aneela; Dyvorne, Hadrien A; Taouli, Bachir

    2016-02-01

    To quantify hepatocellular carcinoma (HCC) perfusion and flow with the fast exchange regime-allowed Shutter-Speed model (SSM) compared to the Tofts model (TM). In this prospective study, 25 patients with HCC underwent DCE-MRI. ROIs were placed in liver parenchyma, portal vein, aorta and HCC lesions. Signal intensities were analyzed employing dual-input TM and SSM models. ART (arterial fraction), K (trans) (contrast agent transfer rate constant from plasma to extravascular extracellular space), ve (extravascular extracellular volume fraction), kep (contrast agent intravasation rate constant), and τi (mean intracellular water molecule lifetime) were compared between liver parenchyma and HCC, and ART, K (trans), v e and k ep were compared between models using Wilcoxon tests and limits of agreement. Test-retest reproducibility was assessed in 10 patients. ART and v e obtained with TM; ART, ve, ke and τi obtained with SSM were significantly different between liver parenchyma and HCC (p < 0.04). Parameters showed variable reproducibility (CV range 14.7-66.5% for both models). Liver K (trans) and ve; HCC ve and kep were significantly different when estimated with the two models (p < 0.03). Our results show differences when computed between the TM and the SSM. However, these differences are smaller than parameter reproducibilities and may be of limited clinical significance.

  8. Prospective evaluation of stress myocardial perfusion imaging for pre-operative cardiac risk assessment

    International Nuclear Information System (INIS)

    Byrne, A.J.; Rowe, C.C.; Flannery, G.

    2002-01-01

    Full text: A prospective evaluation of patients who underwent stress myocardial perfusion imaging (MPI) to assess preoperative cardiac risk was undertaken. At the time of the scan patients were classified into 4 Clinical Risk groups (CR) based on known clinical data. On completion of the scan, the patient was then categorised into 4 Scan based Risk groups (SR), incorporating size of perfusion deficit, single versus multi-vessel disease and ejection fraction. Surgery at Austin and Repatriation Medical Centre within 6 months of scan and complications were identified using the hospital medical database. Major early cardiac events coded were death (cardiac related), myocardial infarction, unstable angina, acute pulmonary oedema, cardiac arrest, and urgent revascularisation. 208 patients have reached 6 months post-MPI scan. Of these 119 (57%) were identified as having surgery. Of the Scan Risk groups, 63% of normal, 57% of increased, and 47% of high and very high groups have had surgery. An abnormal scan is associated with a three-fold risk of cardiac complication (3.5% vs 11.3%). This is lower than most previous reports and may be due to higher representation of low risk surgical procedures (14% in this series), improved peri-operative care and/or the test result influence on management (suggested by decreasing surgical rate as SR estimate rose). Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  9. Comparison of semi-quantitative and quantitative dynamic contrast-enhanced MRI evaluations of vertebral marrow perfusion in a rat osteoporosis model.

    Science.gov (United States)

    Zhu, Jingqi; Xiong, Zuogang; Zhang, Jiulong; Qiu, Yuyou; Hua, Ting; Tang, Guangyu

    2017-11-14

    This study aims to investigate the technical feasibility of semi-quantitative and quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in the assessment of longitudinal changes of marrow perfusion in a rat osteoporosis model, using bone mineral density (BMD) measured by micro-computed tomography (micro-CT) and histopathology as the gold standards. Fifty rats were randomly assigned to the control group (n=25) and ovariectomy (OVX) group whose bilateral ovaries were excised (n=25). Semi-quantitative and quantitative DCE-MRI, micro-CT, and histopathological examinations were performed on lumbar vertebrae at baseline and 3, 6, 9, and 12 weeks after operation. The differences between the two groups in terms of semi-quantitative DCE-MRI parameter (maximum enhancement, E max ), quantitative DCE-MRI parameters (volume transfer constant, K trans ; interstitial volume, V e ; and efflux rate constant, K ep ), micro-CT parameter (BMD), and histopathological parameter (microvessel density, MVD) were compared at each of the time points using an independent-sample t test. The differences in these parameters between baseline and other time points in each group were assessed via Bonferroni's multiple comparison test. A Pearson correlation analysis was applied to assess the relationships between DCE-MRI, micro-CT, and histopathological parameters. In the OVX group, the E max values decreased significantly compared with those of the control group at weeks 6 and 9 (p=0.003 and 0.004, respectively). The K trans values decreased significantly compared with those of the control group from week 3 (pquantitative DCE-MRI, the quantitative DCE-MRI parameter K trans is a more sensitive and accurate index for detecting early reduced perfusion in osteoporotic bone.

  10. Theoretical considerations in measurement of time discrepancies between input and myocardial time-signal intensity curves in estimates of regional myocardial perfusion with first-pass contrast-enhanced MRI.

    Science.gov (United States)

    Natsume, Takahiro; Ishida, Masaki; Kitagawa, Kakuya; Nagata, Motonori; Sakuma, Hajime; Ichihara, Takashi

    2015-11-01

    The purpose of this study was to develop a method to determine time discrepancies between input and myocardial time-signal intensity (TSI) curves for accurate estimation of myocardial perfusion with first-pass contrast-enhanced MRI. Estimation of myocardial perfusion with contrast-enhanced MRI using kinetic models requires faithful recording of contrast content in the blood and myocardium. Typically, the arterial input function (AIF) is obtained by setting a region of interest in the left ventricular cavity. However, there is a small delay between the AIF and the myocardial curves, and such time discrepancies can lead to errors in flow estimation using Patlak plot analysis. In this study, the time discrepancies between the arterial TSI curve and the myocardial tissue TSI curve were estimated based on the compartment model. In the early phase after the arrival of the contrast agent in the myocardium, the relationship between rate constant K1 and the concentrations of Gd-DTPA contrast agent in the myocardium and arterial blood (LV blood) can be described by the equation K1={dCmyo(tpeak)/dt}/Ca(tpeak), where Cmyo(t) and Ca(t) are the relative concentrations of Gd-DTPA contrast agent in the myocardium and in the LV blood, respectively, and tpeak is the time corresponding to the peak of Ca(t). In the ideal case, the time corresponding to the maximum upslope of Cmyo(t), tmax, is equal to tpeak. In practice, however, there is a small difference in the arrival times of the contrast agent into the LV and into the myocardium. This difference was estimated to correspond to the difference between tpeak and tmax. The magnitudes of such time discrepancies and the effectiveness of the correction for these time discrepancies were measured in 18 subjects who underwent myocardial perfusion MRI under rest and stress conditions. The effects of the time discrepancies could be corrected effectively in the myocardial perfusion estimates. Copyright © 2015 Elsevier Inc. All rights

  11. Important parameters in the detection of left main trunk disease using stress myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Shiba, Chie; Chikamori, Taishiro; Hida, Satoshi

    2009-01-01

    We sought noninvasively to diagnose left main trunk (LMT) disease using myocardial perfusion imaging (MPI). Five hundred and eight patients with suspected coronary artery disease (CAD) underwent both stress MPI and coronary angiography. The extent and severity of perfusion abnormalities were assessed using a 20-segment model. In addition, perfusion defects in both left anterior descending and left circumflex arterial territories were defined as a left main (LM) pattern defect, and those in 3-coronary arterial territories as a 3-vessel pattern defect. In 42 patients with LMT disease, a summed stress score (19.4±10.0 vs. 13.5±10.0; p<0.0001) and a summed rest score (12.1±9.7 vs. 7.0±7.8; p=0.002) were greater than in 466 patients without LMT disease, while a summed difference score was similar (7.3±7.7 vs. 6.5±6.1; p=NS). The prevalence of an LM-pattern defect was low in both groups (12% vs. 8%; p=NS). However, a 3-vessel pattern defect (33% vs. 7%; p<0.0001), lung uptake of radiotracers (38% vs. 11%; p<0.0001), and transient ischemic dilation (31% vs. 13%; p=0.003) were more frequently observed in patients with LMT disease than in those without. Logistic regression analysis showed that a 3-vessel pattern defect (odds ratio (OR)=3.5, 95% confidence interval (CI)=1.4-8.8; p=0.007), lung uptake of radiotracers (OR=2.5, 95% CI=1.1-5.7; p=0.03), and previous myocardial infarction (MI) (OR=2.4, 95% CI=1.0-5.7; p=0.05) were the most important parameters to detect LMT disease. After excluding 163 patients with previous MI, a repeat analysis revealed that lung uptake of radiotracers (OR=8.2, 95% CI=2.3-29.2; p=0.001) and an LM-pattern defect (OR=6.3, 95% CI=1.4-27.2; p<0.02) were independent predictors for LMT disease. In the identification of LMT disease, lung uptake of radiotracers was a single best parameter, which was independent of the presence or absence of previous MI. (author)

  12. Comparing kidney perfusion using noncontrast arterial spin labeling MRI and microsphere methods in an interventional swine model.

    Science.gov (United States)

    Artz, Nathan S; Wentland, Andrew L; Sadowski, Elizabeth A; Djamali, Arjang; Grist, Thomas M; Seo, Songwon; Fain, Sean B

    2011-02-01

    The purpose of this study was to assess the ability of a flow-sensitive alternating inversion recovery-arterial spin labeling (FAIR-ASL) technique to track renal perfusion changes during pharmacologic and physiologic alterations in renal blood flow using microspheres as a gold standard. Fluorescent microsphere and FAIR-ASL perfusion were compared in the cortex of the kidney for 11 swine across 4 interventional time points: (1) under baseline conditions, (2) during an acetylcholine and fluid bolus challenge to increase perfusion, (3) initially after switching to isoflurane anesthesia, and (4) after 2 hours of isoflurane anesthesia. In 10 of the 11 swine, a bag of ice was placed on the hilum of 1 kidney at the beginning of isoflurane administration to further reduce perfusion in 1 kidney. Both ASL and microspheres tracked the expected cortical perfusion changes (P values were systematically lower compared with microsphere perfusion. Very good correlation (r = 0.81, P values in the expected physiologic range (microsphere perfusion values saturated for perfusion >550 mL/min/100 g. Cortical perfusion measured with ASL correlated with microspheres and reliably detected changes in renal perfusion in response to physiologic challenge.

  13. WE-AB-202-12: Voxel-Wise Analysis of Apparent Diffusion Coefficient and Perfusion Maps in Multi-Parametric MRI of Prostate Cancer

    International Nuclear Information System (INIS)

    Engstroem, K; Casares-Magaz, O; Muren, L; Roervik, J; Andersen, E

    2016-01-01

    Purpose: Multi-parametric MRI (mp-MRI) is being introduced in radiotherapy (RT) of prostate cancer, including for tumour delineation in focal boosting strategies. We recently developed an image-based tumour control probability model, based on cell density distributions derived from apparent diffusion coefficient (ADC) maps. Beyond tumour volume and cell densities, tumour hypoxia is also an important determinant of RT response. Since tissue perfusion from mp-MRI has been related to hypoxia we have explored the patterns of ADC and perfusion maps, and the relations between them, inside and outside prostate index lesions. Methods: ADC and perfusion maps from 20 prostate cancer patients were used, with the prostate and index lesion delineated by a dedicated uro-radiologist. To reduce noise, the maps were averaged over a 3×3×3 voxel cube. Associations between different ADC and perfusion histogram parameters within the prostate, inside and outside the index lesion, were evaluated with the Pearson’s correlation coefficient. In the voxel-wise analysis, scatter plots of ADC vs perfusion were analysed for voxels in the prostate, inside and outside of the index lesion, again with the associations quantified with the Pearson’s correlation coefficient. Results: Overall ADC was lower inside the index lesion than in the normal prostate as opposed to ktrans that was higher inside the index lesion than outside. In the histogram analysis, the minimum ktrans was significantly correlated with the maximum ADC (Pearson=0.47; p=0.03). At the voxel level, 15 of the 20 cases had a statistically significant inverse correlation between ADC and perfusion inside the index lesion; ten of the cases had a Pearson < −0.4. Conclusion: The minimum value of ktrans across the tumour was correlated to the maximum ADC. However, on the voxel level, the ‘local’ ktrans in the index lesion is inversely (i.e. negatively) correlated to the ‘local’ ADC in most patients. Research agreement with

  14. Perfusion MRI (dynamic susceptibility contrast imaging) with different measurement approaches for the evaluation of blood flow and blood volume in human gliomas

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, H. (Den Sundhedsfaglige Kandidatuddannelse, Aarhus Universitet Bygning 1264, Aarhus (Denmark); University College Nordjylland, Aalborg (Denmark)), Email: hnt@ucn.dk; Steffensen, E. (Aalborg Hospital/Aarhus University Hospital, Department of Radiology, Aalborg (Denmark)); Larsson, E. M. (Aalborg Hospital/Aarhus University Hospital, Department of Radiology, Aalborg (Denmark); Uppsala University Hospital, Department of Radiology, Uppsala (Sweden))

    2012-02-15

    Background. Perfusion magnetic resonance imaging (MRI) is increasingly used in the evaluation of brain tumors. Relative cerebral blood volume (rCBV) is usually obtained by dynamic susceptibility contrast (DSC) MRI using normal appearing white matter as reference region. The emerging perfusion technique arterial spin labelling (ASL) presently provides measurement only of cerebral blood flow (CBF), which has not been widely used in human brain tumor studies. Purpose. To assess if measurement of blood flow is comparable with measurement of blood volume in human biopsy-proven gliomas obtained by DSC-MRI using two different regions for normalization and two different measurement approaches. Material and Methods. Retrospective study of 61 patients with different types of gliomas examined with DSC perfusion MRI. Regions of interest (ROIs) were placed in tumor portions with maximum perfusion on rCBF and rCBV maps, with contralateral normal appearing white matter and cerebellum as reference regions. Larger ROIs were drawn for histogram analyses. The type and grade of the gliomas were obtained by histopathology. Statistical comparison was made between diffuse astrocytomas, anaplastic astrocytomas, and glioblastomas. Results. rCBF and rCBV measurements obtained with the maximum perfusion method were correlated when normalized to white matter (r = 0.60) and to the cerebellum (r = 0.49). Histogram analyses of rCBF and rCBV showed that mean and median values as well as skewness and peak position were correlated (0.61 < r < 0.93), whereas for kurtosis and peak height, the correlation coefficient was about 0.3 when comparing rCBF and rCBV values for the same reference region. Neither rCBF nor rCBV quantification provided a statistically significant difference between the three types of gliomas. However, both rCBF and rCBV tended to increase with tumor grade and to be lower in patients who had undergone resection/treatment. Conclusion. rCBF measurements normalized to white matter

  15. Assessment of myocardial perfusion with MRI using a modified dual bolus method

    International Nuclear Information System (INIS)

    Husso, M; Sipola, P; Manninen, H; Vainio, P; Kuittinen, T; Hartikainen, J; Saarakkala, S; Töyräs, J; Kuikka, J

    2014-01-01

    Quantification of regional myocardial blood flow (rMBF) with first-pass magnetic resonance imaging (FP-MRI) requires two contrast agent injections (dual bolus technique), inducing error in the determined rMBF if the injections differ. We hypothesize that using input and residue curves of the same injection would be more reliable. We aim to introduce and evaluate a novel method to correct the high concentration arterial input function (AIF) for determination of rMBF. Sixteen patients with non-Hodgkin's lymphoma were examined before and after chemotherapy. The input function was solved by correcting initial high concentration AIF using the ratio of low and high contrast AIF areas, normalized by corresponding heart rates (modified dual bolus method). For comparison, the scaled low contrast AIF was used as an input function (dual bolus method). Unidirectional transfer coefficient K trans  was calculated using both methods. K trans -values determined with the dual bolus (0.81 ± 0.32 ml g −1  min −1 ) and modified dual bolus (0.77 ± 0.42 ml g −1  min −1 ) methods were in agreement (p = 0.21). Mean K trans -values increased from 0.76 ± 0.43 to 0.89 ± 0.55 ml g −1  min −1  after chemotherapy (p = 0.17). The modified dual bolus technique agrees with the dual bolus technique (R2 = 0.899) when the low and high contrast injections are similar. However, when this is not the case, the modified dual bolus technique may be more reliable. (paper)

  16. The New Frontier of Cardiac Computed Tomography Angiography: Fractional Flow Reserve and Stress Myocardial Perfusion.

    Science.gov (United States)

    Pontone, Gianluca; Muscogiuri, Giuseppe; Andreini, Daniele; Guaricci, Andrea I; Guglielmo, Marco; Mushtaq, Saima; Baggiano, Andrea; Conte, Edoardo; Beltrama, Virginia; Annoni, Andrea; Formenti, Alberto; Mancini, Elisabetta; Rabbat, Mark G; Pepi, Mauro

    2016-12-01

    The increased number of patients with coronary artery disease (CAD) in developed countries is of great clinical relevance and involves a large burden of the healthcare system. The management of these patients is focused on relieving symptoms and improving clinical outcomes. Therefore the ideal test would provide the correct diagnosis and actionable information. To this aim, several non-invasive functional imaging modalities are usually used as gatekeeper to invasive coronary angiography (ICA), but their diagnostic yield remains low with limited accuracy when compared to obstructive CAD at the time of ICA or invasive fractional flow reserve (FFR). Invasive FFR is considered the gold standard for the evaluation of functionally relevant CAD. Therefore, an urgent need for non-invasive techniques that evaluate both the functional and morphological severity of CAD is growing. Coronary computed tomography angiography (CCTA) has emerged as a unique non-invasive technique providing coronary artery anatomic imaging. More recently, the evaluation of FFR with CCTA (FFR CT ) has demonstrated high diagnostic performance compared to invasive FFR. Additionally, stress myocardial computed tomography perfusion (CTP) represents a novel tool for the diagnosis of ischemia with high diagnostic accuracy. Compared to nuclear imaging and cardiac magnetic resonance imaging, both FFR CT and stress-CTP, allow us to integrate the anatomical evaluation of coronary arteries with the functional relevance of coronary artery lesions having the potential to revolutionize the diagnostic paradigm of suspected CAD. FFR CT and stress-CTP could be assimilated in diagnostic pathways of patients with stable CAD and will likely result in a decrease of invasive diagnostic procedures and costs. The current review evaluates the technical aspects and clinical experience of FFR CT and stress-CTP in the evaluation of functionally relevant CAD discussing the strengths and weaknesses of each approach.

  17. Usefulness of combination post-stress dysfunction and perfusion imaging in technetium-99m-tetrofosmin myocardial scintigraphy

    International Nuclear Information System (INIS)

    Yamazaki, Yoko; Imai, Kamon; Konaka, Ryohei; Nakajima, Takatomo; Goto, Sayaka; Horie, Toshinobu; Saito, Satoshi; Ozawa, Yukio; Kanmatsuse, Katsuo

    2001-01-01

    Myocardial perfusion imaging has lower sensitivity for the diagnosis of coronary artery disease in patients with three-vessel disease. The presence of post-stress dysfunction of the left ventricle, evaluated by electrocardiography (ECG) gated single photon emission computed tomography (SPECT) with a quantitative gated SPECT program, was investigated in patients with coronary artery disease, and also whether combining post-stress dysfunction and myocardial perfusion imaging improved the diagnosis of coronary artery disease. ECG gated technetium-99m-tetrofosmin SPECT was performed using a one day, stress and rest, protocol in 139 patients. SPECT and coronary angiography were performed within 1 month. The coronary artery disease group consisted of 89 patients: 43 with one-vessel disease (1VD), 28 with two-vessel disease (2VD), and 18 with three-vessel disease (3VD). The group with zero-vessel disease (0VD) consisted of 50 patients. According to post-stress and rest ejection fraction (EF) and end-systolic volume (ESV), post-stress dysfunction is defined as follows: rest EF - post-stress EF≥5% and post-stress ESV - rest ESV≥5ml. In the coronary artery disease group, post-stress ESV was larger than rest ESV (37.8±26.4, 34.0±24.2 ml, p<0.001), and post-stress EF was lower than rest EF (61.5±11.1%, 64.2±10.8%, p<0.001). In the 0VD group, ESV and EF were the same for post-stress and rest (25.7±20.8, 26.2±21.6 ml, NS; 70.4±9.5%, 70.0±9.6%, NS). Post-stress dysfunction was 6.0% in the 0VD group and 30.3% in the coronary artery disease group (p<0.001). Furthermore, post-stress dysfunction in the 2VD (35.7%) and 3VD (38.9%) groups was higher than that in the 0VD group (p<0.01, p<0.01). Sensitivity of coronary artery disease diagnosis by myocardial perfusion imaging was 75%. The combination of post-stress dysfunction and myocardial perfusion imaging improved sensitivity from 75% to 82% (p<0.05), but reduced the specificity from 92% to 86% (p=0.08). Post-stress

  18. Predictive value of myocardial perfusion scintigraphy after stress in patients without previous myocardial infarction

    International Nuclear Information System (INIS)

    Tuner, D.A.; Battle, W.E.; Deshmukh, H.; Colandrea, M.A.; Snyder, G.J.; Fordham, E.W.; Messer, J.V.

    1978-01-01

    Seventy-five patients who had chest pain but no history or ECG evidence of myocardial infarction (MI) underwent myocardial-stress perfusion scintigraphy (MSPS) with thallium-201, treadmill-stress testing (TST), and coronary cineangiography (CA). The sensitivities of MSPS and TST for coronary stenosis greater than or equal to 75 percent were 68 percent and 71 percent, respectively; their specificities were 97 percent and 79 percent, respectively (0.1 greater than p greater than 0.05). When the character of a patient's chest pain is considered, Bayesian analysis leads to the following conclusions: MSPS can be useful in pre-CA screening of patients with chest pain but no MI if their pain is thought to be of uncertain or nonischemic origin; the sensitivity of Tl-201 MSPS is not sufficient for pre-CA screening of patients without MI who have typical or atypical angina pectoris; the sensitivity of MSPS would have to be approximately 95 percent in order for the test to be useful in pre-CA screening of patients who have atypical angina pectoris; MSPS may be superior to TST in these applications; and it is not clear that there is any advantage in combining MSPS and TST into a single screening test rather than using MSPS alone

  19. Inter-observer variability of visual analysis of "stress"-only adenosine first-pass myocardial perfusion imaging in relation to clinical experience and reading criteria

    NARCIS (Netherlands)

    Lubbers, D. D.; Kuijpers, D.; Bodewes, R.; Kappert, P.; Kerkhof, M.; van Ooijen, P. M. A.; Oudkerk, M.

    To assess the inter-observer agreement of adenosine "stress"-only visual analysis of perfusion MR images in relation to experience and reading criteria. 106 adenosine perfusion MR examinations out of 350, 46 consecutive positive examinations and 60 randomly selected negative examinations were

  20. Prognostic implications of post-stress ejection fraction decrease detected by gated SPECT in the absence of stress-induced perfusion abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Dona, Manjola; Massi, Lucia; Settimo, Leonardo; Bartolini, Matteo; Gianni, Gianluca; Pupi, Alberto; Sciagra, Roberto [University of Florence, Nuclear Medicine Unit, Department of Clinical Physiopathology, Florence (Italy)

    2011-03-15

    The prognostic meaning of a post-stress ejection fraction (EF) decrease detected by perfusion gated SPECT is still unclear. We therefore followed up patients with post-stress EF decrease in the absence of stress-induced perfusion abnormalities. We prospectively enrolled 57 consecutive patients with post-stress EF drop {>=} 5 EF units and summed difference score (SDS) {<=} 1. They were followed up for more than 1 year and their outcome was compared with a group of sex- and age-matched controls with the same SDS but without EF decrease. During follow-up there were 13 events (1 cardiac death, 1 non-fatal myocardial infarction, 1 congestive heart failure and 10 late revascularizations). In the control group we registered six events. There was a significant difference (p < 0.0001) between the event-free survival curves of the two groups. The event rate of patients with post-stress EF decrease {>=} 5 EF units is relatively high and is significantly worse than that of a control group of patients with similarly normal SDS but without EF changes. Therefore, a post-stress EF decrease without stress-induced perfusion abnormalities should be cautiously interpreted. (orig.)

  1. Early perfusion changes within 1 week of systemic treatment measured by dynamic contrast-enhanced MRI may predict survival in patients with advanced hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Bang-Bin; Yu, Chih-Wei; Liang, Po-Chin [National Taiwan University College of Medicine and Hospital, Department of Medical Imaging and Radiology, Taipei City (China); Hsu, Chao-Yu [National Taiwan University College of Medicine and Hospital, Department of Medical Imaging and Radiology, Taipei City (China); Taipei Hospital, Ministry of Health and Welfare, Department of Radiology, New Taipei City (China); Hsu, Chiun; Hsu, Chih-Hung; Cheng, Ann-Lii [National Taiwan University College of Medicine and Hospital, Department of Oncology, Taipei City (China); Shih, Tiffany Ting-Fang [National Taiwan University College of Medicine and Hospital, Department of Medical Imaging and Radiology, Taipei City (China); Taipei City Hospital, Department of Medical Imaging, Taipei City (China); National Taiwan University Hospital, Department of Medical Imaging, Taipei (China)

    2017-07-15

    To correlate early changes in the parameters of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) within 1 week of systemic therapy with overall survival (OS) in patients with advanced hepatocellular carcinoma (HCC). Eighty-nine patients with advanced HCC underwent DCE-MRI before and within 1 week following systemic therapy. The relative changes of six DCE-MRI parameters (Peak, Slope, AUC, Ktrans, Kep and Ve) of the tumours were correlated with OS using the Kaplan-Meier model and the double-sided log-rank test. All patients died and the median survival was 174 days. Among the six DCE-MRI parameters, reductions in Peak, AUC, and Ktrans, were significantly correlated with one another. In addition, patients with a high Peak reduction following treatment had longer OS (P = 0.023) compared with those with a low Peak reduction. In multivariate analysis, a high Peak reduction was an independent favourable prognostic factor in all patients [hazard ratio (HR), 0.622; P = 0.038] after controlling for age, sex, treatment methods, tumour size and stage, and Eastern Cooperative Oncology Group performance status. Early perfusion changes within 1 week following systemic therapy measured by DCE-MRI may aid in the prediction of the clinical outcome in patients with advanced HCC. (orig.)

  2. Rest/stress myocardial perfusion imaging: A means to prevent missed acute ischemic coronary syndrome diagnoses

    International Nuclear Information System (INIS)

    Fink-Bennett, D.; Pattekar, A.M.

    2002-01-01

    Aim: The sensitivity and specificity of rest/stress (R/S) myocardial perfusion imaging (MPI) in detecting an acute ischemic coronary syndrome (AICS) was determined in 100 consecutive patients (pts) admitted to the Chest Pain Clinic-Observation Unit (CPC-OU) with chest pain (CP) of suspected cardiac etiology and a negative (neg) or non diagnostic (dx) EKG. There were 57 females and 43 males, 30-83 years of age. 50 studies were performed from 1/15/98 to 4/2/98; 50 from 11/19/99 to 1/10/00. Material and Methods: An AICS was deemed present if a reversible perfusion defect was demonstrated scintigraphically; a ?50% luminal narrow angiographically. No AICS if the pt had a normal R/S MPI, a fixed defect with normal wall motion and thickening, a neg cardiac catheterization, or was free of cardiac symptoms and had no history of a vascular event for 2-3 years post CPC-OU admission. 13 pts with a positive MPI had a cardiac catheterization, none with a neg MPI. SPECT rest MPI's were performed 30-90 minutes (mins) post 10.0 mCi of technetium 99m Sestamibi. SPECT stress MPI's were performed following a 6-8 hour acute myocardial infarction enzyme (CP-MB/Troponin 1) rule out and 30-90 mins post 30.0 mCi of technetium 99m Sestamibi. Results: 29 pts were lost to follow-up. There were 12 true positive, 5 false positive, 54 true negative and 0 false negative studies. The sensitivity, specificity, positive and negative predictive value of a R/S MPI in detecting an AICS is 100%, 91%, 70% and 100%, respectively. An AICS was detected in 12% of pts admitted to the CPC-OU; a finding that correlates with its reported incidence of 2-12%. 6 were managed medically, 3 required emergent bypass surgery, 3 were stented. Conclusion: R/S MPI should be included in the CPC-OU dx work-up of pts with CP of suspected cardiac etiology to prevent missed AICS diagnoses. Patient care will be optimized and health care and medical malpractice awards for failure to diagnosis an acute myocardial infarction

  3. Time-resolved 3D pulmonary perfusion MRI: comparison of different k-space acquisition strategies at 1.5 and 3 T.

    Science.gov (United States)

    Attenberger, Ulrike I; Ingrisch, Michael; Dietrich, Olaf; Herrmann, Karin; Nikolaou, Konstantin; Reiser, Maximilian F; Schönberg, Stefan O; Fink, Christian

    2009-09-01

    Time-resolved pulmonary perfusion MRI requires both high temporal and spatial resolution, which can be achieved by using several nonconventional k-space acquisition techniques. The aim of this study is to compare the image quality of time-resolved 3D pulmonary perfusion MRI with different k-space acquisition techniques in healthy volunteers at 1.5 and 3 T. Ten healthy volunteers underwent contrast-enhanced time-resolved 3D pulmonary MRI on 1.5 and 3 T using the following k-space acquisition techniques: (a) generalized autocalibrating partial parallel acquisition (GRAPPA) with an internal acquisition of reference lines (IRS), (b) GRAPPA with a single "external" acquisition of reference lines (ERS) before the measurement, and (c) a combination of GRAPPA with an internal acquisition of reference lines and view sharing (VS). The spatial resolution was kept constant at both field strengths to exclusively evaluate the influences of the temporal resolution achieved with the different k-space sampling techniques on image quality. The temporal resolutions were 2.11 seconds IRS, 1.31 seconds ERS, and 1.07 VS at 1.5 T and 2.04 seconds IRS, 1.30 seconds ERS, and 1.19 seconds VS at 3 T.Image quality was rated by 2 independent radiologists with regard to signal intensity, perfusion homogeneity, artifacts (eg, wrap around, noise), and visualization of pulmonary vessels using a 3 point scale (1 = nondiagnostic, 2 = moderate, 3 = good). Furthermore, the signal-to-noise ratio in the lungs was assessed. At 1.5 T the lowest image quality (sum score: 154) was observed for the ERS technique and the highest quality for the VS technique (sum score: 201). In contrast, at 3 T images acquired with VS were hampered by strong artifacts and image quality was rated significantly inferior (sum score: 137) compared with IRS (sum score: 180) and ERS (sum score: 174). Comparing 1.5 and 3 T, in particular the overall rating of the IRS technique (sum score: 180) was very similar at both field

  4. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K. [Southern Health and Monash University, Monash Cardiovascular Research Centre, Monash Heart, Department of Medicine Monash Medical Centre (MMC), Melbourne (Australia); Nandurkar, Dee; Troupis, John M. [MMC, Southern Health, Department of Diagnostic Imaging, Melbourne (Australia)

    2013-07-15

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 {+-} 7.4 mSv compared with 13.2 {+-} 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  5. Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study

    International Nuclear Information System (INIS)

    Nasis, Arthur; Ko, Brian S.; Leung, Michael C.; Antonis, Paul R.; Wong, Dennis T.; Kyi, Leo; Cameron, James D.; Meredith, Ian T.; Seneviratne, Sujith K.; Nandurkar, Dee; Troupis, John M.

    2013-01-01

    To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 ± 7.4 mSv compared with 13.2 ± 2.2 mSv for SPECT-MPI (P < 0.001). Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. (orig.)

  6. Confluence of depression and acute psychological stress among patients with stable coronary heart disease: effects on myocardial perfusion.

    Science.gov (United States)

    Burg, Matthew M; Meadows, Judith; Shimbo, Daichi; Davidson, Karina W; Schwartz, Joseph E; Soufer, Robert

    2014-10-30

    Depression is prevalent in coronary heart disease (CHD) patients and increases risk for acute coronary syndrome (ACS) recurrence and mortality despite optimal medical care. The pathways underlying this risk remain elusive. Psychological stress (PS) can provoke impairment in myocardial perfusion and trigger ACS. A confluence of acute PS with depression might reveal coronary vascular mechanisms of risk. We tested whether depression increased risk for impaired myocardial perfusion during acute PS among patients with stable CHD. Patients (N=146) completed the Beck Depression Inventory-I (BDI-I), a measure of depression linked to recurrent ACS and post-ACS mortality, and underwent single-photon emission computed tomography myocardial perfusion imaging at rest and during acute PS. The likelihood of new/worsening impairment in myocardial perfusion from baseline to PS as a function of depression severity was tested. On the BDI-I, 41 patients scored in the normal range, 48 in the high normal range, and 57 in the depressed range previously linked to CHD prognosis. A BDI-I score in the depressed range was associated with a significantly greater likelihood of new/worsening impairment in myocardial perfusion from baseline to PS (odds ratio =2.89, 95% CI: 1.26 to 6.63, P=0.012). This remained significant in models controlling ACS recurrence/mortality risk factors and medications. There was no effect for selective serotonin reuptake inhibitor medications. Depressed patients with CHD are particularly susceptible to impairment in myocardial perfusion during PS. The confluence of PS with depression may contribute to a better understanding of the depression-associated risk for ACS recurrence and mortality. © 2014 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  7. Diagnostic value of stress-rest myocardial perfusion imaging in detection of coronary disease in elderly patients

    International Nuclear Information System (INIS)

    Han Pingping; Tian Yueqin; Fang Wei; Shen Rui; Yang Minfu; Wei Hongxing; Guo Xinhua; He Zuoxiang

    2009-01-01

    Objective: Coronary artery disease is one of the most common causes of death in elderly people. Yet, definite diagnosis is a dilemma due to the variety of symptoms and signs. The aim of this study was to evaluate the diagnostic value of nuclear stress-rest myocardial perfusion imaging(MPI) in detection of coronary disease in the elderly. Methods: Two hundred and five elderly subjects (≥60 years old, average of 67 ± 5) who were suspected to have coronary disease, underwent both stress-rest myocardial perfusion imaging (185 with exercise stress and 20 with adenosine stress) and coronary angiography (CAG). All had no pereutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG). Coronary angiography was used as a 'golden standard' to evaluate the sensitivity, specificity and accuracy of the stress-rest myocardial perfusion imaging. χ 2 -test was used in data analysis with SPSS 15.0. Results: Among 205 patients. there were 57 patients with an abnormal CAG result and 148 patients with a normal result. Of the 57 patients, there were 30 one-, 19 two-, and 8 three-vessel stenosis. Fifteen were mild-, 17 were moderate-, 17 were severe stenosis, and 8 were totally occluded.About 63% (36/57) had positive stress-rest MPI. Of the 148 subjects who had a normal CAG, 135 had negative MPL. The sensitivity.specificity and accuracy of stress MPI were 63% (36/57), 91% (135/148) and 83% (171/205) in patient level.respectively. The di-agnostic sensitivities of stress-rest MPI for detection of one-, two-, and three-vessel stenosis were 57%(17/30), 58% (11/19) and 8/8, respectively. All 185 patients who underwent exemise stress MPI were divided into 2 groups according to whether the patients reached the target heart rate or not at the peak of the test. And 53 patients (29%) were group 1 (reached the target heart rate)and 132 patients (71%) were group 2 (did not reach the target heart rate). The sensitivity of group 1 wag higher than that of group 2, but with no

  8. Cardiac MRI in ischemic heart disease

    International Nuclear Information System (INIS)

    Ishida, Masaki; Kato, Shingo; Sakuma, Hajime

    2009-01-01

    Considerable progress has been made in cardiac magnetic resonance imaging (MRI). Cine MRI is recognized as the most accurate method for evaluating ventricular function. Late gadolinium-enhanced MRI can clearly delineate subendocardial infarction, and the assessment of transmural extent of infarction on MRI is widely useful for predicting myocardial viability. Stress myocardial perfusion MRI allows for detection of subendocardial myocardial ischemia, and the diagnostic accuracy of stress perfusion MRI is superior to stress perfusion single-photon emission computed tomography in patients with multivessel coronary artery disease (CAD). In recent years, image quality, volume coverage, acquisition speed and arterial contrast of 3-dimensional coronary magnetic resonance angiography (MRA) have been substantially improved with use of steady-state free precession sequences and parallel imaging techniques, permitting the acquisition of high-quality, whole-heart coronary MRA within a reasonably short imaging time. It is now widely recognized that cardiac MRI has tremendous potential for the evaluation of ischemic heart disease. However, cardiac MRI is technically complicated and its use in clinical practice is relatively limited. With further improvements in education and training, as well as standardization of appropriate study protocols, cardiac MRI will play a central role in managing patients with CAD. (author)

  9. Adenosine stress and exercise 99Tcm-MIBI myocardial perfusion imaging in the diagnosis and risk stratification of patients with unstable angina

    International Nuclear Information System (INIS)

    Jia Peng; Guo Wanhua; Xu Shoulin; Feng Xuefeng

    2008-01-01

    Objective: The aim of this study was to evaluate the clinical value of adenosine stress or exercise 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging in the diagnosis and risk stratification of patients with unstable angina. Methods: Eighty-seven hospitalized patients with unstable angina [54 men and 33 women, aged of (56.5±12.5) years] underwent adenosine stress or exercise myocardial perfusion imaging and coronary angiography. Patients were followed up. Results: Fifty-seven patients had abnormal myocardial perfusion imaging and significant coronary artery stenosis. Ten patients had abnormal myocardial perfusion imaging but normal coronary angiography. Eight patients had normal myocardial perfusion imaging but significant coronary artery stenosis. Twelve patients had normal myocardial perfusion imaging and normal coronary angiography. Patients with abnormal myocardial perfusion imaging had worse prognosis. There was relationship between cardiac events and the extent and severity of myocardial ischemia. Conclusion: Adenosine stress and exercise myocardial perfusion imaging is of important clinical value in the diagnosis and risk stratification of patients with unstable angina. (authors)

  10. Effects of resting state condition on reliability, trait specificity, and network connectivity of brain function measured with arterial spin labeled perfusion MRI.

    Science.gov (United States)

    Li, Zhengjun; Vidorreta, Marta; Katchmar, Natalie; Alsop, David C; Wolf, Daniel H; Detre, John A

    2018-06-01

    Resting state fMRI (rs-fMRI) provides imaging biomarkers of task-independent brain function that can be associated with clinical variables or modulated by interventions such as behavioral training or pharmacological manipulations. These biomarkers include time-averaged regional brain function as manifested by regional cerebral blood flow (CBF) measured using arterial spin labeled (ASL) perfusion MRI and correlated temporal fluctuations of function across brain networks with either ASL or blood oxygenation level dependent (BOLD) fMRI. Resting-state studies are typically carried out using just one of several prescribed state conditions such as eyes closed (EC), eyes open (EO), or visual fixation on a cross-hair (FIX), which may affect the reliability and specificity of rs-fMRI. In this study, we collected test-retest ASL MRI data during 4 resting-state task conditions: EC, EO, FIX and PVT (low-frequency psychomotor vigilance task), and examined the effects of these task conditions on reliability and reproducibility as well as trait specificity of regional brain function. We also acquired resting-state BOLD fMRI under FIX and compared the network connectivity reliabilities between the four ASL conditions and the BOLD FIX condition. For resting-state ASL data, EC provided the highest CBF reliability, reproducibility, trait specificity, and network connectivity reliability, followed by EO, while FIX was lowest on all of these measures. PVT demonstrated lower CBF reliability, reproducibility and trait specificity than EO and EC. Overall network connectivity reliability was comparable between ASL and BOLD. Our findings confirm ASL CBF as a reliable, stable, and consistent measure of resting-state regional brain function and support the use of EC or EO over FIX and PVT as the resting-state condition. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  11. Detection of Local Tumor Recurrence After Definitive Treatment of Head and Neck Squamous Cell Carcinoma: Histogram Analysis of Dynamic Contrast-Enhanced T1-Weighted Perfusion MRI.

    Science.gov (United States)

    Choi, Sang Hyun; Lee, Jeong Hyun; Choi, Young Jun; Park, Ji Eun; Sung, Yu Sub; Kim, Namkug; Baek, Jung Hwan

    2017-01-01

    This study aimed to explore the added value of histogram analysis of the ratio of initial to final 90-second time-signal intensity AUC (AUCR) for differentiating local tumor recurrence from contrast-enhancing scar on follow-up dynamic contrast-enhanced T1-weighted perfusion MRI of patients treated for head and neck squamous cell carcinoma (HNSCC). AUCR histogram parameters were assessed among tumor recurrence (n = 19) and contrast-enhancing scar (n = 27) at primary sites and compared using the t test. ROC analysis was used to determine the best differentiating parameters. The added value of AUCR histogram parameters was assessed when they were added to inconclusive conventional MRI results. Histogram analysis showed statistically significant differences in the 50th, 75th, and 90th percentiles of the AUCR values between the two groups (p Histogram analysis of AUCR can improve the diagnostic yield for local tumor recurrence during surveillance after treatment for HNSCC.

  12. Altered myocardial perfusion during dobutamine stress testing in silent versus symptomatic myocardial ischaemia assessed by quantitative MIBI SPET imaging

    International Nuclear Information System (INIS)

    Elhendy, A.; Geleijnse, M.L.; Roelandt, J.R.T.C.; Cornel, J.H.; Domburg, R.T van; Reijs, A.E.M.; Nierop, P.R.; Fioretti, P.M.

    1996-01-01

    The aim of the study was to compare the extent and severity of reversible underperfusion in silent versus painful myocardial ischaemia during the dobutamine stress test. A consecutive series of 85 patients with significant coronary artery disease and reversible perfusion defects on technetium-99m methoxyisobutylisonitrile single-photon emission tomography performed at rest and during high-dose dobutamine stress (up to 40 μg kg -1 min -1 ) were studied. The left ventricle was divided into six segments. An ischaemic perfusion score was derived quantitatively by subtracting the rest from the stress defect score. Patients with multivessel disease had a higher ischaemic score (610±762 vs 310±411, P<0.05) and a higher number of reversible perfusion defects (2.1±1.2 vs 1.1±0.8, P<0.01) than patients with single-vessel disease. Typical angina occurred in 37 patients (44%) during the test. There was no significant difference between patients with and patients without angina with respecft to age, gender, peak rate-pressure product, prevalence of previous myocardial infarction, diabetes mellitus, multivessel disease or number of stenotic coronary arteries. Stress, rest and ischaemic scores as well as the number and distribution of reversible defects were not different in patients with and patients without angina. Patients with angina more frequently had a history of typical angina before the test (43% vs 17%, P<0.01) and ST-segment depression during the test (54% vs 25%, P<0.01). It is concluded that in patients with coronary artery disease and ischaemia detected by dobutamine scintigraphy, the extent and severity of coronary artery disease and myocardial perfusion abnormalities are similar with or without angina during stess testing. (orig.)

  13. Safety and efficacy of Regadenoson in myocardial perfusion imaging (MPI) stress tests: A review

    Science.gov (United States)

    Ahmed, Ambereen

    2018-02-01

    Myocardial perfusion imaging (MPI) tests are often used to help diagnose coronary heart disease (CAD). The tests usually involve applying stress, such as hard physical exercise together with administration of vasodilators, to the patients. To date, many of these tests use non-selective A2A adenosine receptor agonists which, however, can be associated with highly undesirable and life-threatening side effects such as chest pain, dyspnea, severe bronchoconstriction and atrioventricular conduction anomalies. Regadenoson is a relatively new, highly selective A2A adenosine receptor agonist, suitable for use in MPI tests which exhibits far fewer adverse side effects and, unlike others testing agents, can be used without the necessity of excessive concomitant exercise. Also, the dose of regadenoson required is not dependent upon patient weight or renal impairment, and it can be rapidly administered by i.v. Injection. Regadenoson use in MPI testing thus has the potential as a simplified, relatively safe, time-saving and cost-effective method for helping diagnose CAD. The present study was designed to review several articles on the safety, efficacy, and suitability of regadenoson in MPI testing for CAD. Overall, the combined studies demonstrated that use of regadenoson in conjunction with low-level exercise in MPI is a highly efficient and relatively safe test for CAD, especially for more severe health-compromised patients.

  14. Evaluating the effect of PTCA by exercise stress myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Lin Jinghui

    1992-01-01

    In this study, 44 patients after successful percutaneous transluminal coronary angioplasty (PTCA) were followed up by exercise stress myocardial perfusion imaging. In 28 patients with myocardial ischemia after PTCA, myocardial imaging of 75.0% patients reverted to normal or approximately normal. In 16 patients of myocardial infarction with ischemia after PTCA, myocardial imaging of only 37.5% patients reverted to normal or approximately normal, significantly less than myocardial ischemia. But the general efficacious incidence was similar in both groups. Most of 77 myocardial segments with complete or obvious redistribution returned to normal imaging after PTCA. During the follow-up coronary artery restenosis occurred in 6 cases, 5 of which were confirmed by coronary arteriography. Restenosis may be discovered as soon as possible, if a patient was reexamined by myocardial imaging 2-6 months after PTCA. The results of this study indicated that myocardial imaging is a noninvasive and reliable method for the assessment of PTCA therapeutic effect and follow up studies

  15. TH-CD-206-01: Expectation-Maximization Algorithm-Based Tissue Mixture Quantification for Perfusion MRI

    Energy Technology Data Exchange (ETDEWEB)

    Han, H; Xing, L [Stanford University, Palo Alto, CA (United States); Liang, Z [Stony Brook University, Stony Brook, NY (United States); Li, L [City University of New York College of Staten Island, Staten Island, NY (United States)

    2016-06-15

    Purpose: To investigate the feasibility of estimating the tissue mixture perfusions and quantifying cerebral blood flow change in arterial spin labeled (ASL) perfusion MR images. Methods: The proposed perfusion MR image analysis framework consists of 5 steps: (1) Inhomogeneity correction was performed on the T1- and T2-weighted images, which are available for each studied perfusion MR dataset. (2) We used the publicly available FSL toolbox to strip off the non-brain structures from the T1- and T2-weighted MR images. (3) We applied a multi-spectral tissue-mixture segmentation algorithm on both T1- and T2-structural MR images to roughly estimate the fraction of each tissue type - white matter, grey matter and cerebral spinal fluid inside each image voxel. (4) The distributions of the three tissue types or tissue mixture across the structural image array are down-sampled and mapped onto the ASL voxel array via a co-registration operation. (5) The presented 4-dimensional expectation-maximization (4D-EM) algorithm takes the down-sampled three tissue type distributions on perfusion image data to generate the perfusion mean, variance and percentage images for each tissue type of interest. Results: Experimental results on three volunteer datasets demonstrated that the multi-spectral tissue-mixture segmentation algorithm was effective to initialize tissue mixtures from T1- and T2-weighted MR images. Compared with the conventional ASL image processing toolbox, the proposed 4D-EM algorithm not only generated comparable perfusion mean images, but also produced perfusion variance and percentage images, which the ASL toolbox cannot obtain. It is observed that the perfusion contribution percentages may not be the same as the corresponding tissue mixture volume fractions estimated in the structural images. Conclusion: A specific application to brain ASL images showed that the presented perfusion image analysis method is promising for detecting subtle changes in tissue perfusions

  16. TH-CD-206-01: Expectation-Maximization Algorithm-Based Tissue Mixture Quantification for Perfusion MRI

    International Nuclear Information System (INIS)

    Han, H; Xing, L; Liang, Z; Li, L

    2016-01-01

    Purpose: To investigate the feasibility of estimating the tissue mixture perfusions and quantifying cerebral blood flow change in arterial spin labeled (ASL) perfusion MR images. Methods: The proposed perfusion MR image analysis framework consists of 5 steps: (1) Inhomogeneity correction was performed on the T1- and T2-weighted images, which are available for each studied perfusion MR dataset. (2) We used the publicly available FSL toolbox to strip off the non-brain structures from the T1- and T2-weighted MR images. (3) We applied a multi-spectral tissue-mixture segmentation algorithm on both T1- and T2-structural MR images to roughly estimate the fraction of each tissue type - white matter, grey matter and cerebral spinal fluid inside each image voxel. (4) The distributions of the three tissue types or tissue mixture across the structural image array are down-sampled and mapped onto the ASL voxel array via a co-registration operation. (5) The presented 4-dimensional expectation-maximization (4D-EM) algorithm takes the down-sampled three tissue type distributions on perfusion image data to generate the perfusion mean, variance and percentage images for each tissue type of interest. Results: Experimental results on three volunteer datasets demonstrated that the multi-spectral tissue-mixture segmentation algorithm was effective to initialize tissue mixtures from T1- and T2-weighted MR images. Compared with the conventional ASL image processing toolbox, the proposed 4D-EM algorithm not only generated comparable perfusion mean images, but also produced perfusion variance and percentage images, which the ASL toolbox cannot obtain. It is observed that the perfusion contribution percentages may not be the same as the corresponding tissue mixture volume fractions estimated in the structural images. Conclusion: A specific application to brain ASL images showed that the presented perfusion image analysis method is promising for detecting subtle changes in tissue perfusions

  17. Prognostic value of stress myocardial perfusion positron emission tomography: results from a multicenter observational registry.

    Science.gov (United States)

    Dorbala, Sharmila; Di Carli, Marcelo F; Beanlands, Rob S; Merhige, Michael E; Williams, Brent A; Veledar, Emir; Chow, Benjamin J W; Min, James K; Pencina, Michael J; Berman, Daniel S; Shaw, Leslee J

    2013-01-15

    The primary objective of this multicenter registry was to study the prognostic value of positron emission tomography (PET) myocardial perfusion imaging (MPI) and the improved classification of risk in a large cohort of patients with suspected or known coronary artery disease (CAD). Limited prognostic data are available for MPI with PET. A total of 7,061 patients from 4 centers underwent a clinically indicated rest/stress rubidium-82 PET MPI, with a median follow-up of 2.2 years. The primary outcome of this study was cardiac death (n = 169), and the secondary outcome was all-cause death (n = 570). Net reclassification improvement (NRI) and integrated discrimination analyses were performed. Risk-adjusted hazard of cardiac death increased with each 10% myocardium abnormal with mildly, moderately, or severely abnormal stress PET (hazard ratio [HR]: 2.3 [95% CI: 1.4 to 3.8; p = 0.001], HR: 4.2 [95% CI: 2.3 to 7.5; p statistic 0.805 [95% CI: 0.772 to 0.838] to 0.839 [95% CI: 0.809 to 0.869]) and risk reclassification for cardiac death (NRI 0.116 [95% CI: 0.021 to 0.210]), with smaller improvements in risk assessment for all-cause death. In patients with known or suspected CAD, the extent and severity of ischemia and scar on PET MPI provided powerful and incremental risk estimates of cardiac death and all-cause death compared with traditional coronary risk factors. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Perfusion MRI before and after acetazolamide administration for assessment of cerebrovascular reserve capacity in patients with symptomatic internal carotid artery (ICA) occlusion: comparison with {sup 99m}Tc-ECD SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Ma, J.; Holtmannspoetter, M.; Brueckmann, H. [University of Munich, Department of Neuroradiology, Klinikum Grosshadern, Munich (Germany); Mehrkens, J.H.; Schmid-Elsaesser, R. [University of Munich, Department of Neurosurgery, Klinikum Grosshadern, Munich (Germany); Linke, R. [University of Munich, Department of Nuclear Medicine, Klinikum Grosshadern, Munich (Germany); Steiger, H.J. [Heinrich-Heine University, Department of Neurosurgery, Duesseldorf (Germany); Bruening, R. [University of Munich, Department of Neuroradiology, Klinikum Grosshadern, Munich (Germany); Asklepios Klinik Barmbek, Department of Radiology, Hamburg (Germany)

    2007-04-15

    Impaired cerebral vascular reserve (CVR) in patients with symptomatic internal carotid artery (ICA) occlusion is regarded as a possible indication for performing extra-/intracranial (EC/IC) bypass surgery. As perfusion MR imaging (MRI) can demonstrate cerebral haemodynamics at capillary level, our hypothesis was that perfusion MRI could be used in these patients for the evaluation of CVR following acetazolamide challenge in a similar way to single photon emission CT (SPECT) and might provide additional information. Enrolled in the study were 12 patients (mean age 61.3 years; 11 male, 1 female) with symptomatic unilateral ICA occlusion proven by angiography. Both perfusion MRI and 99m-technetium-ethyl-cysteinate dimer ({sup 99m}Tc-ECD) SPECT were performed before and after injection of acetazolamide (Diamox,1000 mg i.v.). CVR parameters including regional cerebral blood flow (rCBF) and volume (rCBV), and mean transit times (MTT) were measured by perfusion MRI. The patients with impaired CVR proven by SPECT (n = 9) had a negative mean rCBF increment (-46.52%), negative rCBV increment (-13.5%) and delayed MTT (mean +2.98 s), respectively, on the occluded side (Student's t-test all P < 0.05). The patients with sufficient CVR (n = 3) had a mean rCBF increment of 1.2%, a decrement of rCBV of 10.46%, and a mean MTT shortening of 0.27 s following the acetazolamide injection. Perfusion MRI before and after acetazolamide administration compares favourably with {sup 99m}Tc-ECD SPECT for the detection of impaired CVR. The impact that perfusion MRI studies (before and after acetazolamide administration) might have on the treatment decision in patients with ICA occlusion has yet to be determined by a prospective study. (orig.)

  19. Myocardial perfusion imaging with dual energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); De Cecco, Carlo N. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncology and Pathology, University of Rome “Sapienza”, Rome (Italy); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Spandorfer, Adam; Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States)

    2016-10-15

    Highlights: • Stress dual-energy sCTMPI offers the possibility to directly detect the presence of myocardial perfusion defects. • Stress dual-energy sCTMPI allows differentiating between reversible and fixed myocardial perfusion defects. • The combination of coronary CT angiography and dual-energy sCTMPI can improve the ability of CT to detect hemodynamically relevant coronary artery disease. - Abstract: Dual-energy CT (DECT) enables simultaneous use of two different tube voltages, thus different x-ray absorption characteristics are acquired in the same anatomic location with two different X-ray spectra. The various DECT techniques allow material decomposition and mapping of the iodine distribution within the myocardium. Static dual-energy myocardial perfusion imaging (sCTMPI) using pharmacological stress agents demonstrate myocardial ischemia by single snapshot images of myocardial iodine distribution. sCTMPI gives incremental values to coronary artery stenosis detected on coronary CT angiography (CCTA) by showing consequent reversible or fixed myocardial perfusion defects. The comprehensive acquisition of CCTA and sCTMPI offers extensive morphological and functional evaluation of coronary artery disease. Recent studies have revealed that dual-energy sCTMPI shows promising diagnostic accuracy for the detection of hemodynamically significant coronary artery disease compared to single-photon emission computed tomography, invasive coronary angiography, and cardiac MRI. The aim of this review is to present currently available DECT techniques for static myocardial perfusion imaging and recent clinical applications and ongoing investigations.

  20. Large cerebral perfusion defects observed in brain perfusion SPECT may herald psychiatric or neurodegenerative diseases of transient global amnesia patients

    International Nuclear Information System (INIS)

    So, Young; Kim, Hahn Young; Roh, Hong Gee; Han, Seol Heui

    2007-01-01

    Transient global amnesia (TGA) is a memory disorder characterized by an episode of antegrade amnesia and bewilderment which persists for several hours. We analyzed brain perfusion SPECT findings and clinical outcome of patients who suffered from TGA. From September 2005 to August 2007, 12 patients underwent Tc-99m ECD brain perfusion SPECT for neuroimaging of TGA. All patients also underwent MRI and MRA including DWI (MRI). Among them, 10 patients who could be chased more than 6 months were included in this study. Their average age was 60.74.0 yrs (M: F = 2: 8) and the average duration of amnesia was 4.42.2 hrs (1 hr ∼ 7 hrs). Duration from episode of amnesia to SPECT was 4.32.4 days (1∼9 days). Precipitating factors could be identified in 6 patients: emotional stress 3, hair dyeing 1, taking a nap 1 and angioplasty 1. SPECT and MRI was visually assessed, No cerebral perfusion defect was observed on SPECT in 3 patients and their clinical outcome was all good. Among 7 patients who had cerebral perfusion defects on SPECT, 3 patients had good clinical outcome, while others did not: one had hypercholesterolemia, another had depression, and 2 patients with cerebral perfusion defects at both temporoparetal cortex was later diagnosed as early Alzheimer's disease (AD) and mild cognitive impairment (MCI). MRI was negative in 6 patients and 3 of them had excellent clinical outcome while other 3 were diagnosed as hypercholesterolemia, early AD and MCI. Among 4 patients with positive MRI, 3 showed good clinical outcome and their MRI showed lesions at medial temporal cortex and/or vertebral artery. One patient with microcalcification at left putamen was diagnosed to have depression. Large cerebral perfusion defects on SPECT may herald psychiatric or neurodegenerative diseases of transient global amnesia patients which usually shows negative MRI

  1. Large cerebral perfusion defects observed in brain perfusion SPECT may herald psychiatric or neurodegenerative diseases of transient global amnesia patients

    Energy Technology Data Exchange (ETDEWEB)

    So, Young; Kim, Hahn Young; Roh, Hong Gee; Han, Seol Heui [Konkuk University School of Medicine, Seoul (Korea, Republic of)

    2007-07-01

    Transient global amnesia (TGA) is a memory disorder characterized by an episode of antegrade amnesia and bewilderment which persists for several hours. We analyzed brain perfusion SPECT findings and clinical outcome of patients who suffered from TGA. From September 2005 to August 2007, 12 patients underwent Tc-99m ECD brain perfusion SPECT for neuroimaging of TGA. All patients also underwent MRI and MRA including DWI (MRI). Among them, 10 patients who could be chased more than 6 months were included in this study. Their average age was 60.74.0 yrs (M: F = 2: 8) and the average duration of amnesia was 4.42.2 hrs (1 hr {approx} 7 hrs). Duration from episode of amnesia to SPECT was 4.32.4 days (1{approx}9 days). Precipitating factors could be identified in 6 patients: emotional stress 3, hair dyeing 1, taking a nap 1 and angioplasty 1. SPECT and MRI was visually assessed, No cerebral perfusion defect was observed on SPECT in 3 patients and their clinical outcome was all good. Among 7 patients who had cerebral perfusion defects on SPECT, 3 patients had good clinical outcome, while others did not: one had hypercholesterolemia, another had depression, and 2 patients with cerebral perfusion defects at both temporoparetal cortex was later diagnosed as early Alzheimer's disease (AD) and mild cognitive impairment (MCI). MRI was negative in 6 patients and 3 of them had excellent clinical outcome while other 3 were diagnosed as hypercholesterolemia, early AD and MCI. Among 4 patients with positive MRI, 3 showed good clinical outcome and their MRI showed lesions at medial temporal cortex and/or vertebral artery. One patient with microcalcification at left putamen was diagnosed to have depression. Large cerebral perfusion defects on SPECT may herald psychiatric or neurodegenerative diseases of transient global amnesia patients which usually shows negative MRI.

  2. Perfusion maps of the whole liver based on high temporal and spatial resolution contrast-enhanced MRI (4D THRIVE): Feasibility and initial results in focal liver lesions

    International Nuclear Information System (INIS)

    Coenegrachts, Kenneth; Ghekiere, Johan; Denolin, Vincent; Gabriele, Beck; Herigault, Gwen; Haspeslagh, Marc; Daled, Peter; Bipat, Shandra; Stoker, Jaap; Rigauts, Hans

    2010-01-01

    Purpose: To prospectively evaluate a new imaging sequence (4D THRIVE) for whole liver perfusion in high temporal and spatial resolution. Feasibility of parametric mapping and its potential for characterizing focal liver lesions (FLLs) are investigated. Materials and methods: Fifteen patients suspected for colorectal liver metastases (LMs) were included. Parametric maps were evaluated qualitatively (ring-enhancement and lesion heterogeneity) and compared to three-phased contrast-enhanced MRI. Quantitative analysis was based on average perfusion values of entire FLLs. Reference standard comprised surgery with histopathology or follow-up imaging. Fisher's exact test was used for qualitative and Kruskal-Wallis test for quantitative analysis. Results: In total 29 LMs, 17 hemangiomas and 4 focal nodular hyperplasias were evaluated. FLLs could be differentiated by qualitative assessment of parametric maps respectively three-phased contrast-enhanced MRI (Fisher's p < 0.001 for comparisons between LMs and hemangiomas and LMs and FNHs for both ring-enhancement and lesion heterogeneity) rather than by quantitative analysis of parametric maps (Chi-square for Kep = 0.33 (p = 0.847) and Chi-square for Kel = 1.35 (p = 0.509)). Conclusion: This preliminary study shows potential of 4D THRIVE for whole liver imaging enabling calculation of parametric maps. Qualitative rather than quantitative analysis was accurate for differentiating malignant and benign FLLs.

  3. Alterations of the Blood-Brain Barrier and Regional Perfusion in Tumor Development: MRI Insights from a Rat C6 Glioma Model.

    Science.gov (United States)

    Huhndorf, Monika; Moussavi, Amir; Kramann, Nadine; Will, Olga; Hattermann, Kirsten; Stadelmann, Christine; Jansen, Olav; Boretius, Susann

    2016-01-01

    Angiogenesis and anti-angiogenetic medications play an important role in progression and therapy of glioblastoma. In this context, in vivo characterization of the blood-brain-barrier and tumor vascularization may be important for individual prognosis and therapy optimization. We analyzed perfusion and capillary permeability of C6-gliomas in rats at different stages of tumor-growth by contrast enhanced MRI and dynamic susceptibility contrast (DSC) MRI at 7 Tesla. The analyses included maps of relative cerebral blood volume (CBV) and signal recovery derived from DSC data over a time period of up to 35 days after tumor cell injections. In all rats tumor progression was accompanied by temporal and spatial changes in CBV and capillary permeability. A leakage of the blood-brain barrier (slow contrast enhancement) was observed as soon as the tumor became detectable on T2-weighted images. Interestingly, areas of strong capillary permeability (fast signal enhancement) were predominantly localized in the center of the tumor. In contrast, the tumor rim was dominated by an increased CBV and showed the highest vessel density compared to the tumor center and the contralateral hemisphere as confirmed by histology. Substantial regional differences in the tumor highlight the importance of parameter maps in contrast or in addition to region-of-interest analyses. The data vividly illustrate how MRI including contrast-enhanced and DSC-MRI may contribute to a better understanding of tumor development.

  4. Detection of coronary artery disease - comparison of exercise stress radionuclide angiocardiography and thallium stress perfusion scanning

    International Nuclear Information System (INIS)

    Jengo, J.A.; Freeman, R.; Brizendine, M.; Mena, I.; St. Mary Medical Center, Long Beach, Calif.)

    1980-01-01

    Exercise thallium scanning and stress radionuclide angiography were compared in 16 normal subjects and 42 patients with more than 75% coronary arterial obstruction in studies using upright exercise on a bicycle ergometer. Studies at rest were subsequently obtained. Exercise thallium scans in the control group were normal in 15 and showed a defect in 1. Ejection fraction increased in all 16. During exercise, regional wall motion increased uniformly. In the group with coronary artery disease, thallium scanning revealed a new defect in the distribution of the involved arteries in 24 patients. In 15 who had a defect at rest, no new defect developed, but in 9 of the 15 new segmental wall motion defects were evident on radionuclide angiography. With exercise, ejection fraction decreased slightly. Regional wall motion abnormalities developed in the areas corresponding to thallium defects in all. Thallium scanning had a 93% and radionuclide angiography a 98% sensitivity value in detecting coronary artery disease. The respective specificity values were 94 and 100%. In patients with prior myocardial infarction who manifested new exercise abnormalities, 50% showed new thallium defects and 81% new wall motion defects

  5. Assessment of the zonal variation of perfusion parameters in the femoral head. A 3-T dynamic contrast-enhanced MRI pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Budzik, Jean-Francois [Lille Catholic University, Imaging Department, Lille Catholic Hospitals, Lille (France); Littoral Cote d' Opale University, Lille University, Lille (France); Lefebvre, Guillaume [University of Lille Nord de France, Musculoskeletal Imaging Department, Centre de Consultation et d' Imagerie de l' Appareil Locomoteur, CHU Lille, Lille (France); Behal, Helene [University of Lille Nord de France, Biostatistics Department, Lille Regional University Hospital, Lille (France); Verclytte, Sebastien [Lille Catholic University, Imaging Department, Lille Catholic Hospitals, Lille (France); Hardouin, Pierre [Lille University, Littoral Cote d' Opale University, Lille (France); Teixeira, Pedro [Centre Hospitalier Universitaire de Nancy, Service d' Imagerie Guilloz, Hopital Central, Nancy (France); Cotten, Anne [Littoral Cote d' Opale University, Lille University, Lille (France); University of Lille Nord de France, Musculoskeletal Imaging Department, Centre de Consultation et d' Imagerie de l' Appareil Locomoteur, CHU Lille, Lille (France)

    2018-02-15

    The objective was to describe MR perfusion characteristics of the femoral head, with a focus on the subchondral bone. This prospective monocentric study was approved by our local Ethics Committee. Written informed consent was obtained from all subjects. Dynamic contrast-enhanced MRI of the right hip was performed in 59 adults with suspected spondyloarthritis (32 women, 28 men). Mean age was 37.5 (±12.5) years. Regions of interest were drawn in the femoral head epiphysis, in the subchondral areas the most exposed to mechanical load (superolateral, anterosuperior, and posterior zones) and in areas less exposed to mechanical load (inferior subchondral zone and center of the femoral head). Semi-quantitative and pharmacokinetic parameters were calculated using the Tofts model. Statistical analysis was performed with a linear mixed model to compare the perfusion parameters in the different femoral head zones. Extravascular extracellular volume and area under the curve were lower in the superolateral zone than in the inferior zone (p = 0.0135 and p < 0.0001 respectively) and the central zone (p = 0.007 and p = 0.0134 respectively). Extravascular extracellular volume and rate constant were lower in the anterosuperior zone than in the inferior zones (p = 0.011 and p = 0.029). In the anterosuperior zone, extravascular extracellular volume was lower, and time to peak was higher than in the central zones (p = 0.0056 and p = 0.0013 respectively). No significant differences were found for any values between other paired zones. The perfusion of femoral head subchondral bone assessed with dynamic contrast-enhanced magnetic resonance imaging is not homogeneous: the areas exposed to more mechanical loading are less perfused. (orig.)

  6. Assessment of the zonal variation of perfusion parameters in the femoral head. A 3-T dynamic contrast-enhanced MRI pilot study

    International Nuclear Information System (INIS)

    Budzik, Jean-Francois; Lefebvre, Guillaume; Behal, Helene; Verclytte, Sebastien; Hardouin, Pierre; Teixeira, Pedro; Cotten, Anne

    2018-01-01

    The objective was to describe MR perfusion characteristics of the femoral head, with a focus on the subchondral bone. This prospective monocentric study was approved by our local Ethics Committee. Written informed consent was obtained from all subjects. Dynamic contrast-enhanced MRI of the right hip was performed in 59 adults with suspected spondyloarthritis (32 women, 28 men). Mean age was 37.5 (±12.5) years. Regions of interest were drawn in the femoral head epiphysis, in the subchondral areas the most exposed to mechanical load (superolateral, anterosuperior, and posterior zones) and in areas less exposed to mechanical load (inferior subchondral zone and center of the femoral head). Semi-quantitative and pharmacokinetic parameters were calculated using the Tofts model. Statistical analysis was performed with a linear mixed model to compare the perfusion parameters in the different femoral head zones. Extravascular extracellular volume and area under the curve were lower in the superolateral zone than in the inferior zone (p = 0.0135 and p < 0.0001 respectively) and the central zone (p = 0.007 and p = 0.0134 respectively). Extravascular extracellular volume and rate constant were lower in the anterosuperior zone than in the inferior zones (p = 0.011 and p = 0.029). In the anterosuperior zone, extravascular extracellular volume was lower, and time to peak was higher than in the central zones (p = 0.0056 and p = 0.0013 respectively). No significant differences were found for any values between other paired zones. The perfusion of femoral head subchondral bone assessed with dynamic contrast-enhanced magnetic resonance imaging is not homogeneous: the areas exposed to more mechanical loading are less perfused. (orig.)

  7. Small average differences in attenuation corrected images between men and women in myocardial perfusion scintigraphy: a novel normal stress database

    International Nuclear Information System (INIS)

    Trägårdh, Elin; Sjöstrand, Karl; Jakobsson, David; Edenbrandt, Lars

    2011-01-01

    The American Society of Nuclear Cardiology and the Society of Nuclear Medicine state that incorporation of attenuation-corrected (AC) images in myocardial perfusion scintigraphy (MPS) will improve image quality, interpretive certainty, and diagnostic accuracy. However, commonly used software packages for MPS usually include normal stress databases for non-attenuation corrected (NC) images but not for attenuation-corrected (AC) images. The aim of the study was to develop and compare different normal stress databases for MPS in relation to NC vs. AC images, male vs. female gender, and presence vs. absence of obesity. The principal hypothesis was that differences in mean count values between men and women would be smaller with AC than NC images, thereby allowing for construction and use of gender-independent AC stress database. Normal stress perfusion databases were developed with data from 126 male and 205 female patients with normal MPS. The following comparisons were performed for all patients and separately for normal weight vs. obese patients: men vs. women for AC; men vs. women for NC; AC vs. NC for men; and AC vs. NC for women. When comparing AC for men vs. women, only minor differences in mean count values were observed, and there were no differences for normal weight vs. obese patients. For all other analyses major differences were found, particularly for the inferior wall. The results support the hypothesis that it is possible to use not only gender independent but also weight independent AC stress databases

  8. A decision support system for stress only myocardial perfusion scintigraphy may save unnecessary rest studies

    DEFF Research Database (Denmark)

    Tägil, K; Jakobsson, D; Lomsky, M

    2013-01-01

    The aim of this study was to investigate the influence of a computer-based decision support system (DSS) on performance and inter-observer variability of interpretations regarding ischaemia and infarction in myocardial perfusion scintigraphy (MPS).......The aim of this study was to investigate the influence of a computer-based decision support system (DSS) on performance and inter-observer variability of interpretations regarding ischaemia and infarction in myocardial perfusion scintigraphy (MPS)....

  9. Comparison of adenosine and exercise stress 201Tl myocardial perfusion imaging for diagnosing coronary heart disease in women

    International Nuclear Information System (INIS)

    Li Jiangjin; Ma Shuren; Meng Tao; Bao Zhi; Cui Jianhe

    2011-01-01

    Objective: To compare the diagnostic value of adenosine and exercise stress myocardial perfusion imaging (MPI) for detecting coronary heart disease (CHD) in women. Methods: One hundred and thirty-eight patients with CHD were randomly divided into two groups: adenosine stress group (n=69)and exercise stress group (n=69). All patients underwent myocardial SPECT evaluation. Coronary angiography (CAG), referred as 'gold standard' , was performed in each patient within 1 week before or after MPI. The diagnostic value of the two stress MPI was compared with χ 2 test or Fisher's exact test. Results: In adenosine stress group, the sensitivity, negative predictive value and accuracy were 88.2% (45/51), 72.7% (16/22), 88.4% (61/69), respectively, which were not significantly different from those of the exercise stress group (91.7% (44/48), 66.7% (8/12), 81.2% (52/64); χ 2 =0.571, 0.714, 0.249, P>0.05). However, the false positive rate of adenosine stress (11.1%, 2/18) was significantly lower than that of exercise stress (50.0%, 8/16), P=0.023. Conclusions: Adenosine and exercise stress MPI have similar value for CHD diagnosis in women, however, adenosine stress MPI may have an advantage of low false positive rate. (authors)

  10. Combined T1-based perfusion MRI and MR angiography in kidney: First experience in normals and pathology

    Energy Technology Data Exchange (ETDEWEB)

    Dujardin, Martine [Department of Radiology/BEFY, UZ Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium)], E-mail: martine.dujardin@gmail.com; Luypaert, Rob [Department of Radiology/BEFY, UZ Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium)], E-mail: rluypaer@vub.ac.be; Vandenbroucke, F. [Department of Radiology/BEFY, UZ Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium)], E-mail: frederik.vandenbroucke@uzbrussel.be; Van der Niepen, Patricia [Department of Nephrology, UZ Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium)], E-mail: hemovnnp@az.vub.ac.be; Sourbron, Steven [Institute of Clinical Radiology, Ludwig-Maximilian-University Munich, Marchioninistrasse 15, 81377 Munchen (Germany)], E-mail: Steven.Sourbron@med.uni-muenchen.de; Verbeelen, Dierik [Department of Nephrology, UZ Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium)], E-mail: dierik.verbeelen@uzbrussel.be; Stadnik, T. [Department of Radiology/BEFY, UZ Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium)], E-mail: tadeusz.stadnik@uzbrussel.be; Mey, Johan de [Department of Radiology/BEFY, UZ Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium)], E-mail: johan.demey@uzbrussel.be

    2009-03-15

    Objectives: To investigate the feasibility of implementing quantitative T1-perfusion in the routine MRA-protocol and to obtain a first experience in normals and pathology. Materials and methods: For perfusion imaging, IR-prepared FLASH (one 4 mm slice at mid-renal level, TR 4.4 ms, TE 2.2 ms, TI 180 ms, FA 50 deg., matrix 128 x 256, bandwidth per pixel 300, 400 dynamics, temporal resolution 0.3 s, total measurement time 2 min) was applied during the injection of 10 ml of standard 0.5 mmol/ml Gadolinium-DTPA solution at 2 ml/s, followed by 3DCE-MRA with bolus tracking (TR 5.4, TE 1.4, FA 40 deg., matrix 192 x 512, NSA 1, slice thickness 1.5 mm), using a second dose of 0.1 mmol Gadolinium-DTPA per kg body weight with a maximum of 20 ml. The T1-weighted signals (perfusion data) were converted to tissue tracer concentrations and deconvolved with an inflow corrected AIF; blood flow, distribution volume, mean transit time and blood flow heterogeneity were derived. Results: MRA quality was uncompromised by the first bolus administered for perfusion purposes. In the normals, average cortical RBF, RVD and MTT were 1.2 ml/min/ml (S.D. 0.3 ml/min/ml), 0.4 ml/ml (S.D. 0.1 ml/ml) and 21 s (S.D. 4 s). These RBF values are lower than those found in the literature, probably due to residual AIF inflow effects. The sensitivity of the technique was sufficient to demonstrate altered perfusion in the examples of pathology. Conclusion: Combined quantitative T1-perfusion and MRA have a potential for noninvasive renovascular screening and may provide an anatomical and physiological evaluation of renal status.

  11. Comparision the value of detecting myocardial viability between low dose dobutamine stress MRI and echocardiography

    International Nuclear Information System (INIS)

    He Yi; Zhang Zhaoqi; Yu Wei; Miao Cuilian; Zhao Yike; Yan Zixu

    2006-01-01

    Objective: To Compare the diagnostic value between low dose dobutamine stress transthrotic echocardiography and low dose dobutamine stress MRI in detecting myocardial viability of chronic myocardial infarction. Methods: Rest and low dose dobutamine (5, 10 μg·kg -1 ·min -1 ) stress transthrotic echocardiography and cine-MRI were performed in 30 patients with chronic myocardial infarction. 24 patients underwent successful revascularization and 10 of them underwent another rest cine-MRI study to assess segmental myocardial functional recovery. Left ventricular were divided into 16 segments, the criteria of viability in different techniques is: MRI: dobutamine induced systolic wall thickening was ≥2 mm in akinetic or diskinetic segments at rest; Echocardiography: wall motion score reduced at least 1 after dobutamine stress in akinetic or' diskinetic segments at rest. Results: One hundren and eight segments showed wall motion abnormalities of 30 patients, 65 and 56 segments shows positive reaction, 43 and 52 segments shows negativereaction in MRI and echocardiography after dobutamine stress respectively. Kappa value of the two techniques is 0.75, concordance in both techniques is 88%. Twenty-four segments showed functional recovery, 14 segments remained dysfunction 3-6 months after revascularization, the sensitivity, specificity and accuracy of detecting myocardial viability in chronic myocardial infarction in MRI and echocardiography is 95.8% vs 79.2% (P>0.05), 85.7% vs 85.7% (P>0.05), 92.1% vs 81.6% (P>0.05) respectively. The sensitivity and accuracy of MRI is a little higher. Conclusion: The ability of detecting myocardial viability by both low dose dobutamine stress transthrotic echocardiography and low dose dobutamine stress MRI is similer, the sensitivity and accuracy of MRI is a little higher. (authors)

  12. Effect of nutritional status on oxidative stress in an ex vivo perfused rat liver.

    Science.gov (United States)

    Stadler, Michaela; Nuyens, Vincent; Seidel, Laurence; Albert, Adelin; Boogaerts, Jean G

    2005-11-01

    Normothermic ischemia-reperfusion is a determinant in liver injury occurring during surgical procedures, ischemic state, and multiple organ failure. The preexisting nutritional status of the liver might contribute to the extent of tissue injury and primary nonfunction. The aim of this study was to determine the role of starvation on hepatic ischemia-reperfusion injury in normal rat livers. Rats were randomly divided into two groups: one had free access to food, the other was fasted for 16 h. The portal vein was cannulated, and the liver was removed and perfused in a closed ex vivo system. Two modes of perfusion were applied in each series of rats, fed and fasting. In the ischemia-reperfusion mode, the experiment consisted of perfusion for 15 min, warm ischemia for 60 min, and reperfusion during 60 min. In the nonischemia mode, perfusion was maintained during the 135-min study period. Five rats were included in each experimental condition, yielding a total of 20 rats. Liver enzymes, potassium, glucose, lactate, free radicals, i.e., dienes and trienes, and cytochrome c were analyzed in perfusate samples. The proportion of glycogen in hepatocytes was determined in tissue biopsies. Transaminases, lactate dehydrogenase, potassium, and free radical concentrations were systematically higher in fasting rats in both conditions, with and without ischemia. Cytochrome c was higher after reperfusion in the fasting rats. Glucose and lactate concentrations were greater in the fed group. The glycogen content decreased in both groups during the experiment but was markedly lower in the fasting rats. In fed rats, liver injury was moderate, whereas hepatocytes integrity was notably impaired both after continuous perfusion and warm ischemia in fasting animals. Reduced glycogen store in hepatocytes may explain reduced tolerance.

  13. Single-photon emission computed tomography myocardial perfusion imaging-assessed stress perfusion defect severity is associated with mortality independent of ethnicity in an Asian population.

    Science.gov (United States)

    Chin, Chee Tang; Gao, Fei; Keng, Felix Y J; Shah, Bimal R; Koh, Angela S; Tan, Ru San; Chua, Terrance S J

    2014-12-01

    Ischemic heart disease is growing by epidemic proportions in Asia. Among patients in Western populations with similar myocardial perfusion imaging (MPI) ischemia severity, ethnicity is independently associated with mortality. We aimed to determine the differential prognostic value of MPI abnormality severity among three major Asian ethnic groups. From 16,921 consecutive patients, we used summed stress score to define increasing abnormal scan severity groups (minimal, mild, moderate, and severe) among Chinese, Indian, and Malay patients. We determined mortality from the national death registry. Using multivariable Cox regression models, we examined the association between ethnicity and mortality. Chinese patients were older than Indians or Malays. Annual all-cause death rates increased with increasing abnormal scan severity in all three ethnicities. After adjustment, ethnicity was not associated with mortality. With Chinese as the reference group, adjusted hazard ratio and 95% CI for Malays and Indians were 1.29 (0.95-1.77) and 1.06 (0.74-1.50) in the minimally abnormal scan group, and 1.20 (0.75-1.91) and 0.82 (0.47-1.45) in the severely abnormal scan group, respectively. Mortality risk is related to the severity of scan abnormality and is independent of ethnicity in Asians. Our findings emphasize the continued utility of MPI in guiding risk stratification in Asia.

  14. Correlation of chronic kidney disease, diabetes and peripheral artery disease with cardiovascular events in patients using stress myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Furuhashi, Tatsuhiko; Masai, Hirofumi; Kunimasa, Taeko; Nakazato, Ryo; Fukuda, Hiroshi; Sugi, Kaoru; Moroi, Masao

    2011-01-01

    Normal stress myocardial perfusion imaging (MPI) studies generally suggest an excellent prognosis for cardiovascular events. Chronic kidney disease (CKD), diabetes and peripheral artery disease (PAD) have been established as the risk factors for cardiovascular events. However, whether these risk factors significantly predict cardiovascular events in patients with normal stress MPI is unclear. The purpose of this study was to evaluate the prognostic value of these risk factors in patients with normal stress MPI. Patients with normal stress MPI (n=372, male=215 and female=157, age=69 years, CKD without hemodialysis=95, diabetes=99, PAD=19, previous coronary artery disease=116) were followed up for 14 months. Normal stress MPI was defined as a summed stress score of 2 and/or persistent proteinuria. Cardiovascular events included cardiac death, non-fatal myocardial infarction and congestive heart failure requiring hospitalization. Cardiovascular events occurred in 20 of 372 patients (5.4%). In univariate Cox regression analysis, PAD, diabetes, diabetic retinopathy, insulin use, anemia, hypoalbuminemia, CKD, left ventricular ejection fraction and pharmacological stress tests were significant predictors of cardiovascular events. In multivariate Cox regression analysis, PAD, diabetes and CKD were independent and significant predictors for cardiovascular events, and their number was the strongest predictor for cardiovascular events (hazard ratio=21.7, P<0.001). PAD, diabetes and CKD are coexisting, independent and significant risk factors for cardiovascular events, CKD being the strongest predictor. The number of coexisting risk factors is important in predicting cardiovascular events in patients with normal stress MPI. (author)

  15. Role of stress myocardial perfusion SPECT scan in detection and management of coronary artery disease: Nairobi experience

    International Nuclear Information System (INIS)

    Makhdomi, K.B.; Warshow, M.M.; Patel, P.K.J.; Shah, D.; Githegi, D.R.M.

    2002-01-01

    Aim: Stress myocardial perfusion scans have acquired a significant role in the detection and management of Coronary Artery Disease. However, this mode of investigation has only recently been available in Nairobi, and this is the first such study from East Africa. We undertook a comparison of our results with that in the literature, to see whether they conformed to it. Materials and Methods: We performed a review of our initial 82 evaluable studies. The scans were performed with 99mTc-Tetrofosmin, using the single day stress-rest protocol with SPECT acquisitions. We carried out a correlation of our scan findings with angiographic data (where available), and clinical follow-up. The clinical end points where furnished by the referring physicians. We focused on myocardial infarction, need for re-vascularisation, and death. The mean clinical follow-up was 21.8 months (range of 12 months to 39 months). Results: Eighty (98%) of the studies revealed concordance with angiographic findings and/or were predictive of clinical outcome. Two studies were discordant, and will be discussed. The results are comparable with those in the literature. Conclusion: It is concluded that stress myocardial perfusion studies, done at our Centre, had a good predictive value, with regards to the presence and severity of disease, and correlated with the clinical outcome data

  16. A hybrid breath hold and continued respiration-triggered technique for time-resolved 3D MRI perfusion studies in lung cancer

    International Nuclear Information System (INIS)

    Hintze, C.; Stemmer, A.; Bock, M.

    2010-01-01

    Assessment of lung cancer perfusion is impaired by respiratory motion. Imaging times for contrast agent wash-out studies often exceed breath hold capabilities, and respiration triggering reduces temporal resolution. Temporally resolved volume acquisition of entire tumors is required to assess heterogeneity. Therefore, we developed and evaluated an MR measurement technique that exceeds a single breath hold, and provides a variable temporal resolution during acquisition while suspending breath-dependent motion. 20 patients with suspected lung cancer were subjected to perfusion studies using a spoiled 3D gradient echo sequence after bolus injection of 0.07 mmol/kg body weight of Gd-DTPA. 10 acquisitions in expiratory breath hold were followed by 50 navigator-triggered acquisitions under free breathing. Post-processing allowed for co-registration of the 3D data sets. An ROI-based visualization of the signal-time curves was performed. In all cases motion-suspended, time-resolved volume data sets (40 x 33 x 10 cm 3 , voxel size: 2.1 x 2.1 x 5.0 mm 3 ) were generated with a variable, initially high temporal resolution (2.25 sec) that was synchronized with the breath pattern and covered up to 8(1)/(2) min. In 7 / 20 cases a remaining offset could be reduced by rigid co-registration. The tumors showed fast wash-in, followed by rapid signal decay (8 / 20) or a plateau. The feasibility of a perfusion study with hybrid breath hold and navigator-triggered time-resolved 3D MRI which combines high initial temporal resolution during breath hold with a long wash-out period under free breathing was demonstrated. (orig.)

  17. Perfusion MRI derived indices of microvascular shunting and flow control correlate with tumor grade and outcome in patients with cerebral glioma

    DEFF Research Database (Denmark)

    Tietze, Anna; Mouridsen, Kim; Lassen-Ramshad, Yasmin

    2015-01-01

    Objectives: Deficient microvascular blood flow control is thought to cause tumor hypoxia and increase resistance to therapy. In glioma patients, we tested whether perfusion-weighted MRI (PWI) based indices of microvascular flow control provide more information on tumor grade and patient outcome...... than does the established PWI angiogenesis marker, cerebral blood volume (CBV). Material and Methods: Seventy-two glioma patients (sixty high-grade, twelve low-grade gliomas) were included. Capillary transit time heterogeneity (CTH) and COV, its ratio to blood mean transit time, provide indices...... of microvascular flow control and the extent to which oxygen can be extracted by tumor tissue. The ability of these parameters and CBV to differentiate tumor grade were assessed by receiver operating characteristic curves and logistic regression. Their ability to predict time to progression and overall survival...

  18. Prognostic value of normal stress-only myocardial perfusion imaging: a comparison between conventional and CZT-based SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yokota, Shu; Ottervanger, Jan Paul; Timmer, Jorik R. [Isala Hospital, Department of Cardiology, Zwolle (Netherlands); Mouden, Mohamed; Engbers, Elsemiek [Isala Hospital, Department of Cardiology, Zwolle (Netherlands); Isala Hospital, Department of Nuclear Medicine, Zwolle (Netherlands); Knollema, Siert; Jager, Pieter L. [Isala Hospital, Department of Nuclear Medicine, Zwolle (Netherlands)

    2016-02-15

    Single photon emission computed tomography (SPECT) myocardial perfusion imaging has proven to have prognostic importance in patients with suspected stable coronary artery disease (CAD). The recently introduced ultrafast cadmium zinc telluride (CZT)-based gamma cameras have been associated with less equivocal findings and more normal interpretations, allowing stress-only imaging to be performed more often. However, it is yet unclear whether normal stress-only CZT SPECT has comparable prognostic value as normally interpreted stress-only conventional SPECT. The study population consisted of 1,650 consecutive patients without known CAD with normal stress-only myocardial perfusion results with either conventional (n = 362) or CZT SPECT (n = 1,288). The incidence of major adverse cardiac events (MACE, all-cause death, non-fatal myocardial infarction and/or coronary revascularization) was compared between the conventional SPECT and CZT SPECT groups. Multivariable analyses using the Cox model were used to adjust for differences in baseline variables. Patients scanned with CZT were less often male (33 vs 39 %), had less often hypercholesterolaemia (41 vs 50 %) and had more often a family history of CAD (57 vs 49 %). At a median follow-up time of 37 months (interquartile range 28-45 months) MACE occurred in 68 patients. The incidence of MACE was 1.5 %/year in the CZT group, compared to 2.0 %/year in the conventional group (p = 0.08). After multivariate analyses, there was a trend to a lower incidence of MACE in the CZT SPECT group (hazard ratio 0.61, 95 % confidence interval 0.35-1.04, p = 0.07). The prognostic value of normal stress-only CZT SPECT is at least comparable and may be even better than that of normal conventional stress SPECT. (orig.)

  19. Validation of Fourier decomposition MRI with dynamic contrast-enhanced MRI using visual and automated scoring of pulmonary perfusion in young cystic fibrosis patients

    International Nuclear Information System (INIS)

    Bauman, Grzegorz; Puderbach, Michael; Heimann, Tobias; Kopp-Schneider, Annette; Fritzsching, Eva; Mall, Marcus A.; Eichinger, Monika

    2013-01-01

    Purpose: To validate Fourier decomposition (FD) magnetic resonance (MR) imaging in cystic fibrosis (CF) patients with dynamic contrast-enhanced (DCE) MR imaging. Materials and methods: Thirty-four CF patients (median age 4.08 years; range 0.16–30) were examined on a 1.5-T MR imager. For FD MR imaging, sets of lung images were acquired using an untriggered two-dimensional balanced steady-state free precession sequence. Perfusion-weighted images were obtained after correction of the breathing displacement and Fourier analysis of the cardiac frequency from the time-resolved data sets. DCE data sets were acquired with a three-dimensional gradient echo sequence. The FD and DCE images were visually assessed for perfusion defects by two readers independently (R1, R2) using a field based scoring system (0–12). Software was used for perfusion impairment evaluation (R3) of segmented lung images using an automated threshold. Both imaging and evaluation methods were compared for agreement and tested for concordance between FD and DCE imaging. Results: Good or acceptable intra-reader agreement was found between FD and DCE for visual and automated scoring: R1 upper and lower limits of agreement (ULA, LLA): 2.72, −2.5; R2: ULA, LLA: ±2.5; R3: ULA: 1.5, LLA: −2. A high concordance was found between visual and automated scoring (FD: 70–80%, DCE: 73–84%). Conclusions: FD MR imaging provides equivalent diagnostic information to DCE MR imaging in CF patients. Automated assessment of regional perfusion defects using FD and DCE MR imaging is comparable to visual scoring but allows for percentage-based analysis

  20. Validation of Fourier decomposition MRI with dynamic contrast-enhanced MRI using visual and automated scoring of pulmonary perfusion in young cystic fibrosis patients

    Energy Technology Data Exchange (ETDEWEB)

    Bauman, Grzegorz, E-mail: g.bauman@dkfz.de [German Cancer Research Center, Division of Medical Physics in Radiology, Im Neuenheimer Feld 223, 69120 Heidelberg (Germany); Puderbach, Michael, E-mail: m.puderbach@dkfz.de [Chest Clinics at the University of Heidelberg, Clinics for Interventional and Diagnostic Radiology, Amalienstr. 5, 69126 Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (Germany); Heimann, Tobias, E-mail: t.heimann@dkfz.de [German Cancer Research Center, Division of Medical and Biological Informatics, Im Neuenheimer Feld 223, 69120 Heidelberg (Germany); Kopp-Schneider, Annette, E-mail: kopp@dkfz.de [German Cancer Research Center, Division of Biostatistics, Im Neuenheimer Feld 223, 69120 Heidelberg (Germany); Fritzsching, Eva, E-mail: eva.fritzsching@med.uni-heidelberg.de [University Hospital Heidelberg, Department of Translational Pulmonology and Division of Pediatric Pulmonology and Allergy and Cystic Fibrosis Center, Im Neuenheimer Feld 430, Heidelberg (Germany); Mall, Marcus A., E-mail: marcus.mall@med.uni-heidelberg.de [Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (Germany); University Hospital Heidelberg, Department of Translational Pulmonology and Division of Pediatric Pulmonology and Allergy and Cystic Fibrosis Center, Im Neuenheimer Feld 430, Heidelberg (Germany); Eichinger, Monika, E-mail: m.eichinger@dkfz.de [Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (Germany); German Cancer Research Center, Division of Radiology, Im Neuenheimer Feld 223, 69120 Heidelberg (Germany)

    2013-12-01

    Purpose: To validate Fourier decomposition (FD) magnetic resonance (MR) imaging in cystic fibrosis (CF) patients with dynamic contrast-enhanced (DCE) MR imaging. Materials and methods: Thirty-four CF patients (median age 4.08 years; range 0.16–30) were examined on a 1.5-T MR imager. For FD MR imaging, sets of lung images were acquired using an untriggered two-dimensional balanced steady-state free precession sequence. Perfusion-weighted images were obtained after correction of the breathing displacement and Fourier analysis of the cardiac frequency from the time-resolved data sets. DCE data sets were acquired with a three-dimensional gradient echo sequence. The FD and DCE images were visually assessed for perfusion defects by two readers independently (R1, R2) using a field based scoring system (0–12). Software was used for perfusion impairment evaluation (R3) of segmented lung images using an automated threshold. Both imaging and evaluation methods were compared for agreement and tested for concordance between FD and DCE imaging. Results: Good or acceptable intra-reader agreement was found between FD and DCE for visual and automated scoring: R1 upper and lower limits of agreement (ULA, LLA): 2.72, −2.5; R2: ULA, LLA: ±2.5; R3: ULA: 1.5, LLA: −2. A high concordance was found between visual and automated scoring (FD: 70–80%, DCE: 73–84%). Conclusions: FD MR imaging provides equivalent diagnostic information to DCE MR imaging in CF patients. Automated assessment of regional perfusion defects using FD and DCE MR imaging is comparable to visual scoring but allows for percentage-based analysis.

  1. Acute caffeine administration impact on working memory-related brain activation and functional connectivity in the elderly: a BOLD and perfusion MRI study.

    Science.gov (United States)

    Haller, S; Rodriguez, C; Moser, D; Toma, S; Hofmeister, J; Sinanaj, I; Van De Ville, D; Giannakopoulos, P; Lovblad, K-O

    2013-10-10

    In young individuals, caffeine-mediated blockade of adenosine receptors and vasoconstriction has direct repercussions on task-related activations, changes in functional connectivity, as well as global vascular effects. To date, no study has explored the effect of caffeine on brain activation patterns during highly demanding cognitive tasks in the elderly. This prospective, placebo-controlled crossover design comprises 24 healthy elderly individuals (mean age 68.8 ± 4.0 years, 17 females) performing a 2-back working memory (WM) task in functional magnetic resonance imaging (fMRI). Analyses include complimentary assessment of task-related activations (general linear model, GLM), functional connectivity (tensorial independent component analysis, TICA), and baseline perfusion (arterial spin labeling). Despite a reduction in whole-brain global perfusion (-22.7%), caffeine-enhanced task-related GLM activation in a local and distributed network is most pronounced in the bilateral striatum and to a lesser degree in the right middle and inferior frontal gyrus, bilateral insula, left superior and inferior parietal lobule as well as in the cerebellum bilaterally. TICA was significantly enhanced (+8.2%) in caffeine versus placebo in a distributed and task-relevant network including the pre-frontal cortex, the supplementary motor area, the ventral premotor cortex and the parietal cortex as well as the occipital cortex (visual stimuli) and basal ganglia. The inverse comparison of placebo versus caffeine had no significant difference. Activation strength of the task-relevant-network component correlated with response accuracy for caffeine yet not for placebo, indicating a selective cognitive effect of caffeine. The present findings suggest that acute caffeine intake enhances WM-related brain activation as well as functional connectivity of blood oxygen level-dependent fMRI in elderly individuals. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.

  2. IDH mutant and 1p/19q co-deleted oligodendrogliomas: tumor grade stratification using diffusion-, susceptibility-, and perfusion-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Yu; Xing, Zhen; She, Dejun; Yang, Xiefeng; Zheng, Yingyan; Xiao, Zebin; Cao, Dairong [First Affiliated Hospital of Fujian Medical University, Department of Radiology, Fuzhou, Fujian (China); Wang, Xingfu [First Affiliated Hospital of Fujian Medical University, Department of Pathology, Fuzhou (China)

    2017-06-15

    Currently, isocitrate dehydrogenase (IDH) mutation and 1p/19q co-deletion are proven diagnostic biomarkers for both grade II and III oligodendrogliomas (ODs). Non-invasive diffusion-weighted imaging (DWI), susceptibility-weighted imaging (SWI), and dynamic susceptibility contrast perfusion-weighted imaging (DSC-PWI) are widely used to provide physiological information (cellularity, hemorrhage, calcifications, and angiogenesis) of neoplastic histology and tumor grade. However, it is unclear whether DWI, SWI, and DSC-PWI are able to stratify grades of IDH-mutant and 1p/19q co-deleted ODs. We retrospectively reviewed the conventional MRI (cMRI), DWI, SWI, and DSC-PWI obtained on 33 patients with IDH-mutated and 1p/19q co-deleted ODs. Features of cMRI, normalized ADC (nADC), intratumoral susceptibility signals (ITSSs), normalized maxim CBV (nCBV), and normalized maximum CBF (nCBF) were compared between low-grade ODs (LGOs) and high-grade ODs (HGOs). Receiver operating characteristic curve and logistic regression were applied to determine diagnostic performances. HGOs tended to present with prominent edema and enhancement. nADC, ITSSs, nCBV, and nCBF were significantly different between groups (all P < 0.05). The combination of SWI and DSC-PWI for grading resulted in sensitivity and specificity of 100.00 and 93.33%, respectively. IDH-mutant and 1p/19q co-deleted ODs can be stratified by grades using cMRI and advanced magnetic resonance imaging techniques including DWI, SWI, and DSC-PWI. Combined ITSSs with nCBV appear to be a promising option for grading molecularly defined ODs in clinical practice. (orig.)

  3. Facing Contrast-Enhancing Gliomas: Perfusion MRI in Grade III and Grade IV Gliomas according to Tumor Area

    Directory of Open Access Journals (Sweden)

    Anna Luisa Di Stefano

    2014-01-01

    Full Text Available Tumoral neoangiogenesis characterizes high grade gliomas. Relative Cerebral Blood Volume (rCBV, calculated with Dynamic Susceptibility Contrast (DSC Perfusion-Weighted Imaging (PWI, allows for the estimation of vascular density over the tumor bed. The aim of the study was to characterize putative tumoral neoangiogenesis via the study of maximal rCBV with a Region of Interest (ROI approach in three tumor areas—the contrast-enhancing area, the nonenhancing tumor, and the high perfusion area on CBV map—in patients affected by contrast-enhancing glioma (grades III and IV. Twenty-one patients were included: 15 were affected by grade IV and 6 by grade III glioma. Maximal rCBV values for each patient were averaged according to glioma grade. Although rCBV from contrast-enhancement and from nonenhancing tumor areas was higher in grade IV glioma than in grade III (5.58 and 2.68; 3.01 and 2.2, resp., the differences were not significant. Instead, rCBV recorded in the high perfusion area on CBV map, independently of tumor compartment, was significantly higher in grade IV glioma than in grade III (7.51 versus 3.78, P=0.036. In conclusion, neoangiogenesis encompasses different tumor compartments and CBV maps appear capable of best characterizing the degree of neovascularization. Facing contrast-enhancing brain tumors, areas of high perfusion on CBV maps should be considered as the reference areas to be targeted for glioma grading.

  4. Prediction of cardiac events in patients with transient left ventricle dilation on stress myocardial perfusion SPECT images

    International Nuclear Information System (INIS)

    Fukuda, Hiroshi; Moroi, Masao

    2005-01-01

    The purpose of this study was to investigate cardiac events in patients with transient left ventricle (LV) dilation on stress myocardial perfusion single-photon emission computed tomography images (MPI). Consecutive patients (n=53, 31 males, mean age 71 years) with transient LV dilation on thallium-201 stress MPI (treadmill: 21, pharmacologic: 32) were followed for 17 months. Follow-up time was censored at the occurrence of cardiac death, congestive heart failure, acute coronary syndrome, or revascularization. Images were scored and then the summed stress score (SSS), summed rest score, and summed difference score were calculated. Cardiac death occurred in 3 patients, hospitalization occurred in 8 patients, and revascularization occurred in 20 patients. The combined cardiac event rate was 59% (76% for exercise stress vs 47% for pharmacologic stress, p=0.034.). Cox regression analysis demonstrated that a combination of higher SSS and slow washout rate was the best predictor of cardiac events (hazard ratio=3.3, p=0.029). A high cardiac event rate is associated with transient LV dilation on thallium-201 stress MPI. The event rate is particularly high for exercise stress MPI. Furthermore, a combination of the SSS and thallium-201 slow washout is the best predictor of cardiac events in patients with transient LV dilation. (author)

  5. Assessment of non-typical worsening of myocardial perfusion in rest in comparison to stress in 99mTc-MIBI SPECT studies. Preliminary report

    International Nuclear Information System (INIS)

    Dabrowski, A.; Szumilak, B.; Wnuk, J.; Konieczna, S.; Teresinska, A.

    2002-01-01

    Worsening of regional rest perfusion in comparison to stress perfusion, observed in a few percentage of myocardial perfusion 99m Tc-MIBI SPECT studies, does not have an easy clinical interpretation. Also, no reports evaluating the relationship between worsening and technical SPECT study conditions are available. The goal of our study is: 1) to assess the reproducibility of this non-typical effect - by repeating the rest study on separate day after new MIBI injection; 2) to assess reproducibility of this effect in rest perfusion images performed at different time points after one MIBI injection; 3) to propose the most probable clinical explanation for this effect. Up to now, 20 patients (100 predicted altogether) with rest perfusion worsening in routine stress-rest 99m Tc-MIBI SPECT perfusion imaging were studied. The group was clinically in homogeneous (7 patients with suspected coronary artery disease (CAD), 4 patients with CAD and no myocardial infarction (MI), 8 patients after MI, and 1 patient with developmental anomaly). Within 14 days, rest study was repeated, with data acquisition performed at 1 h and 3 hrs after MIBI injection. Regional myocardial perfusion was evaluated qualitatively, in 17 segments of the LV and compared among stress and all the three rest (BAD-I, BAD-II, BAD-III) studies. In 175 segments there was perfusion worsening in at least one of the three rest studies. In the highest percentage of these segments (n=53, 30%, ), worsening was present in all rest studies. Among stress defects with perfusion worsening in BAD-I, the highest percentage (55%, ) presented worsening also in BAD-II (performed after separate injection of MIBI, but like in BAD-I also 1 h after injection), significantly lower percentage - persistent defect in BAD-II (25%, ), and some smaller percentage - transient defect in BAD-II (20%, ). In segments with perfusion worsening present in one of the rest studies, our preliminary results show: 1) the highest probability of

  6. Ex-vivo diffusion MRI reveals microstructural alterations in stress-sensitive brain regions: A chronic mild stress recovery study

    DEFF Research Database (Denmark)

    Khan, Ahmad Raza; Hansen, Brian; Wiborg, Ove

    Depression is a leading cause of disability worldwide and causes significant microstructural alterations in stress-sensitive brain regions. However, the potential recovery of these microstructural alterations has not previously been investigated, which we, therefore, set out to do using diffusion...... MRI (d-MRI) in the chronic mild stress (CMS) rat model of depression. This study reveals significant microstructural alterations after 8 weeks of recovery, in the opposite direction to change induced by stress in the acute phase of the experiment. Such findings may be useful in the prognosis...... of depression or for monitoring treatment response....

  7. Accuracy of F-DOPA PET and perfusion-MRI for differentiating radionecrotic from progressive brain metastases after radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Cicone, Francesco; Papa, Annalisa; Scopinaro, Francesco [Sant' Andrea Hospital, Rome (Italy). Unit of Nuclear Medicine; ' ' Sapienza' ' Univ., Rome (Italy). Dept. of Surgical and Medicine Sciences and Translational Medicine; Minniti, Giuseppe; Scaringi, Claudia; Maurizi Enrici, Riccardo [' ' Sapienza' ' Univ., Rome (Italy). Dept. of Surgical and Medicine Sciences and Translational Medicine; Sant' Andrea Hospital, Rome (Italy). Unit of Radiotherapy; Romano, Andrea; Tavanti, Francesca; Bozzao, Alessandro [Sant' Andrea Hospital, Rome (Italy). Unit of Neuroradiology; Rome Univ. (Italy). Dept. of Neurosciences, Mental Health and Sensory Organs (Ne.S.M.O.S.)

    2015-01-15

    We assessed the performance of 6-[{sup 18}F]-fluoro-l-3,4-dihydroxyphenylalanine (F-DOPA) PET for differentiating radionecrosis (RN) from tumour progression (PD) in a population of patients with brain metastases, treated with stereotactic radiosurgery. The accuracy of F-DOPA PET was compared with that of perfusion-weighted magnetic resonance (perfusion-MR). In 42 patients with a total of 50 brain metastases from various primaries F-DOPA PET/CT was performed because of suspected radiological progression at the site of previously irradiated brain metastasis. Several semiquantitative PET parameters were recorded, and their diagnostic accuracy was compared by receiver operating characteristic curve analyses. The diagnosis was established by either surgery or follow-up. A comparison was made between F-DOPA PET and perfusion-MR sequences acquired no more than 3 weeks apart. Definitive outcome was available in 46 of the 50 lesions (20 PD, 26 RN). Of the 46 lesions, 11 were surgically excised while in the remaining 35 lesions the diagnosis was established by radiological and clinical criteria. The best diagnostic performance was obtained using the semiquantitative PET parameter maximum lesion to maximum background uptake ratio (SUVL{sub max}/Bkgr{sub max}). With a cut-off value of 1.59, a sensitivity of 90 % and a specificity of 92.3 % were achieved in differentiating RN from PD lesions (accuracy 91.3 %). Relative cerebral blood volume (rCBV) derived from perfusion-MR was available for comparison in 37 of the 46 metastases. Overall accuracy of rCBV was lower than that of all semiquantitative PET parameters under study. The best differentiating rCBV cut-off value was 2.14; this yielded a sensitivity of 86.7 % and a specificity of 68.2 % (accuracy 75.6 %). F-DOPA PET is a highly accurate tool for differentiating RN from PD brain metastases after stereotactic radiosurgery. In this specific setting, F-DOPA PET seems to perform better than perfusion-MR. (orig.)

  8. Perfusion dyssynchrony analysis

    NARCIS (Netherlands)

    Chiribiri, A.; Villa, A.D.M.; Sammut, E.; Breeuwer, M.; Nagel, E.

    2015-01-01

    AIMS: We sought to describe perfusion dyssynchrony analysis specifically to exploit the high temporal resolution of stress perfusion CMR. This novel approach detects differences in the temporal distribution of the wash-in of contrast agent across the left ventricular wall. METHODS AND RESULTS:

  9. Heat stress presenting with encephalopathy and MRI findings of diffuse cerebral injury and hemorrhage.

    Science.gov (United States)

    Guerrero, Waldo R; Varghese, Shaun; Savitz, Sean; Wu, Tzu Ching

    2013-06-17

    Heat stress results in multiorgan failure and CNS injury. There a few case reports in the literature on the neurological consequences of heat stress. We describe a patient with heat stress presenting with encephalopathy and bilateral cerebral, cerebellar, and thalamic lesions and intraventricular hemorrhage on MRI. Heat stress should be in the differential diagnosis of patients presenting with encephalopathy and elevated serum inflammatory markers especially if the history suggests a preceding episode of hyperthermia.

  10. Dynamic susceptibility contrast (DSC) perfusion MRI in differential diagnosis between radionecrosis and neoangiogenesis in cerebral metastases using rCBV, rCBF and K2.

    Science.gov (United States)

    Muto, Mario; Frauenfelder, Giulia; Senese, Rossana; Zeccolini, Fabio; Schena, Emiliano; Giurazza, Francesco; Jäger, Hans Rolf

    2018-07-01

    Distinction between treatment-related changes and tumour recurrence in patients who have received radiation treatment for brain metastases can be difficult on conventional MRI. In this study, we investigated the ability of dynamic susceptibility contrast (DSC) perfusion in differentiating necrotic changes from pathological angiogenesis and compared measurements of relative cerebral blood volume (rCBV), relative cerebral blood flow (rCBF) and K2, using a dedicated software. Twenty-nine patients with secondary brain tumors were included in this retrospective study and underwent DSC perfusion MRI with a 3-month follow-up imaging after chemo- or radiation-therapy. Region-of-interests were drawn around the contrast enhancing lesions and measurements of rCBV, rCBF and K2 were performed in all patients. Based on subsequent histological examination or clinico-radiological follow-up, the cohort was divided in two groups: recurrent disease and stable disease. Differences between the two groups were analyzed using the Student's t test. Sensitivity, specificity and diagnostic accuracy of rCBV measurements were analyzed considering three different cut-off values. Between patients with and without disease, only rCBV and rCBF values were significant (p < 0.05). The only cut-off value giving the best diagnostic accuracy of 100% was rCBV = 2.1 (sensitivity = 100%; specificity = 100%). Patients with tumor recurrence showed a higher mean value of rCBV (mean = 4.28, standard deviation = 2.09) than patients with necrotic-related changes (mean = 0.77, standard deviation = 0.44). DSC-MRI appears a clinically useful method to differentiate between tumor recurrence, tumor necrosis and pseudoprogression in patients treated for cerebral metastases. Relative CBV using a cut-off value of 2.1 proved to be the most accurate and reliable parameter.

  11. Acetabular stress fractures in military endurance athletes and recruits: incidence and MRI and scintigraphic findings

    International Nuclear Information System (INIS)

    Williams, T.R.; Puckett, M.L.; Shin, A.Y.; Gorman, J.D.; Denison, G.

    2002-01-01

    Objective: To evaluate the incidence and the MRI and scintigraphic appearance of acetabular stress (fatigue) fractures in military endurance athletes and recruits. Design and patients: One hundred and seventy-eight active duty military endurance trainees with a history of activity-related hip pain were evaluated by both MRI and bone scan over a 2-year period. Patients in the study ranged in age from 17 to 45 years. They had hip pain related to activity and had plain radiographs of the hip and pelvis that were interpreted as normal or equivocal. The study was originally designed to evaluate the MRI and scintigraphic appearance of femoral neck stress fractures. Patients had scintigraphy and a limited MRI examination (coronal imaging only) within 48 h of the bone scan. Twelve patients demonstrated imaging findings compatible with acetabular stress fractures. Results: Stress fractures are common in endurance athletes and in military populations; however, stress fracture of the acetabulum is uncommon. Twelve of 178 patients (6.7%) in our study had imaging findings consistent with acetabular stress fractures. Two patterns were identified. Seven of the 12 (58%) patients had acetabular roof stress fractures. In this group, two cases of bilateral acetabular roof stress fractures were identified, one with a synchronous tensile sided femoral neck stress fracture. The remaining five of 12 (42%) patients had anterior column stress fractures, rarely occurring in isolation, and almost always occurring with inferior pubic ramus stress fracture (4 of 5, or 80%). One case of bilateral anterior column stress fractures was identified without additional sites of injury. Conclusions: Stress fractures are commonplace in military populations, especially endurance trainees. Acetabular stress fractures are rare and therefore unrecognized, but do occur and may be a cause for activity-related hip pain in a small percentage of military endurance athletes and recruits. (orig.)

  12. Perfusion imaging of brain gliomas using arterial spin labeling: correlation with histopathological vascular density in MRI-guided biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Di, Ningning; Pang, Haopeng; Ren, Yan; Yao, Zhenwei; Feng, Xiaoyuan [Huashan Hospital Fudan University, Department of Radiology, Shanghai (China); Dang, Xuefei [Shang Hai Gamma Knife Hospital, Shanghai (China); Cheng, Wenna [Binzhou Medical University Affiliated Hospital, Department of Pharmacy, Binzhou (China); Wu, Jingsong; Yao, Chengjun [Huashan Hospital Fudan University, Department of Neurosurgery, Shanghai (China)

    2017-01-15

    This study was designed to determine if cerebral blood flow (CBF) derived from arterial spin labeling (ASL) perfusion imaging could be used to quantitatively evaluate the microvascular density (MVD) of brain gliomas on a ''point-to-point'' basis by matching CBF areas and surgical biopsy sites as accurate as possible. The study enrolled 47 patients with treatment-naive brain gliomas who underwent preoperative ASL, 3D T1-weighted imaging with gadolinium contrast enhancement (3D T1C+), and T2 fluid acquisition of inversion recovery (T2FLAIR) sequences before stereotactic surgery. We histologically quantified MVD from CD34-stained sections of stereotactic biopsies and co-registered biopsy locations with localized CBF measurements. The correlation between CBF and MVD was determined using Spearman's correlation coefficient. P ≤.05 was considered statistically significant. Of the 47 patients enrolled in the study, 6 were excluded from the analysis because of brain shift or poor co-registration and localization of the biopsy site during surgery. Finally, 84 biopsies from 41 subjects were included in the analysis. CBF showed a statistically significant positive correlation with MVD (ρ = 0.567; P =.029). ASL can be a useful noninvasive perfusion MR method for quantitative evaluation of the MVD of brain gliomas. (orig.)

  13. Tumor metabolism and perfusion ratio assessed by 18F-FDG PET/CT and DCE-MRI in breast cancer patients: Correlation with tumor subtype and histologic prognostic factors

    Energy Technology Data Exchange (ETDEWEB)

    An, Young-Sil [Department of Nuclear Medicine and Molecular Imaging, Ajou University School of Medicine (Korea, Republic of); Kang, Doo Kyoung [Department of Radiology, Ajou University School of Medicine (Korea, Republic of); Jung, Yong Sik; Han, Sehwan [Department of Surgery, Ajou University School of Medicine (Korea, Republic of); Kim, Tae Hee, E-mail: medhand@ajou.ac.kr [Department of Radiology, Ajou University School of Medicine (Korea, Republic of)

    2015-07-15

    Highlights: • In non-triple negative breast cancer, metabolic parameter (SUVmax) was significantly correlated with perfusion parameters (Kep and Ve). • In triple negative cancers, any perfusion parameters did not correlated with metabolic parameters. • Higher SUVmax, higher SUVmax/Ktrans, higher MTV50/Ktrans, higher TLG50/Ktrans, higher TLG50/Ve ratios were significantly correlated with TNBC. • In triple negative breast cancer, perfusion and metabolic parameters are not significantly correlated. • Triple negative breast cancer showed higher metabolic–perfusion ratios compared to non-triple negative breast cancer. - Abstract: Objective: Our purpose was to evaluate whether breast cancer with high metabolic–perfusion ratio would be associated with poor histopathologic prognostic factors and whether triple negative breast cancer (TNBC) would show high metabolic–perfusion ratio compared to non-triple negative breast cancer (non-TNBC). Methods: From March 2011 to November 2011, 67 females with invasive ductal carcinoma of breast who underwent both MRI and 18F-FDG PET/CT were included. Perfusion parameters including Ktrans, Kep and Ve were acquired from Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Metabolic parameters including the standardized uptake value (SUV) and volumetric metabolic parameters including metabolic tumor volume (MTV) and total lesion glycolysis (TLG) were obtained from F-18 fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT). Results: In non-TNBC, SUVmax was significantly correlated with Kep (ρ = 0.298, p = 0.036) and Ve (ρ = −0.286, p = 0.044). In TNBC, there was no significant correlation between all perfusion and metabolic parameters. Compared to non-TNBC, higher SUVmax (10.2 vs 5.3, p < 0.001), higher SUVmax/Ktrans (56.02 vs 20.3, p < 0.001), higher MTV50/Ktrans (7.8 vs 16.54, p < 0.001), higher TLG50/Ktrans (36.49 vs 12.3, p < 0.001), higher TLG50/Ve (91.34 vs 27.1 p = 0.022) were

  14. Diffusion-weighted MRI and quantitative biophysical modeling of hippocampal neurite loss in chronic stress.

    Directory of Open Access Journals (Sweden)

    Peter Vestergaard-Poulsen

    Full Text Available Chronic stress has detrimental effects on physiology, learning and memory and is involved in the development of anxiety and depressive disorders. Besides changes in synaptic formation and neurogenesis, chronic stress also induces dendritic remodeling in the hippocampus, amygdala and the prefrontal cortex. Investigations of dendritic remodeling during development and treatment of stress are currently limited by the invasive nature of histological and stereological methods. Here we show that high field diffusion-weighted MRI combined with quantitative biophysical modeling of the hippocampal dendritic loss in 21 day restraint stressed rats highly correlates with former histological findings. Our study strongly indicates that diffusion-weighted MRI is sensitive to regional dendritic loss and thus a promising candidate for non-invasive studies of dendritic plasticity in chronic stress and stress-related disorders.

  15. Myocardial Creatine Levels Do Not Influence Response to Acute Oxidative Stress in Isolated Perfused Heart

    Science.gov (United States)

    Aksentijević, Dunja; Zervou, Sevasti; Faller, Kiterie M. E.; McAndrew, Debra J.; Schneider, Jurgen E.; Neubauer, Stefan; Lygate, Craig A.

    2014-01-01

    Background Multiple studies suggest creatine mediates anti-oxidant activity in addition to its established role in cellular energy metabolism. The functional significance for the heart has yet to be established, but antioxidant activity could contribute to the cardioprotective effect of creatine in ischaemia/reperfusion injury. Objectives To determine whether intracellular creatine levels influence responses to acute reactive oxygen species (ROS) exposure in the intact beating heart. We hypothesised that mice with elevated creatine due to over-expression of the creatine transporter (CrT-OE) would be relatively protected, while mice with creatine-deficiency (GAMT KO) would fare worse. Methods and Results CrT-OE mice were pre-selected for creatine levels 20–100% above wild-type using in vivo 1H–MRS. Hearts were perfused in isovolumic Langendorff mode and cardiac function monitored throughout. After 20 min equilibration, hearts were perfused with either H2O2 0.5 µM (30 min), or the anti-neoplastic drug doxorubicin 15 µM (100 min). Protein carbonylation, creatine kinase isoenzyme activities and phospho-PKCδ expression were quantified in perfused hearts as markers of oxidative damage and apoptotic signalling. Wild-type hearts responded to ROS challenge with a profound decline in contractile function that was ameliorated by co-administration of catalase or dexrazoxane as positive controls. In contrast, the functional deterioration in CrT-OE and GAMT KO hearts was indistinguishable from wild-type controls, as was the extent of oxidative damage and apoptosis. Exogenous creatine supplementation also failed to protect hearts from doxorubicin-induced dysfunction. Conclusions Intracellular creatine levels do not influence the response to acute ROS challenge in the intact beating heart, arguing against creatine exerting (patho-)physiologically relevant anti-oxidant activity. PMID:25272153

  16. Oxidative stress measured in vivo without an exogenous contrast agent using QUEST MRI

    Science.gov (United States)

    Berkowitz, Bruce A.

    2018-06-01

    Decades of experimental studies have implicated excessive generation of reactive oxygen species (ROS) in the decline of tissue function during normal aging, and as a pathogenic factor in a vast array of fatal or debilitating morbidities. This massive body of work has important clinical implications since many antioxidants are FDA approved, readily cross blood-tissue barriers, and are effective at improving disease outcomes. Yet, the potential benefits of antioxidants have remained largely unrealized in patients because conventional methods cannot determine the dose, timing, and drug combinations to be used in clinical trials to localize and decrease oxidative stress. To address this major problem and improve translational success, new methods are urgently needed that non-invasively measure the same ROS biomarker both in animal models and patients with high spatial resolution. Here, we summarize a transformative solution based on a novel method: QUEnch-assiSTed MRI (QUEST MRI). The QUEST MRI index is a significant antioxidant-induced improvement in pathophysiology, or a reduction in 1/T1 (i.e., R1). The latter form of QUEST MRI provides a unique measure of uncontrolled production of endogenous, paramagnetic reactive oxygen species (ROS). QUEST MRI results to-date have been validated by gold standard oxidative stress assays. QUEST MRI has high translational potential because it does not use an exogenous contrast agent and requires only standard MRI equipment. Summarizing, QUEST MRI is a powerful non-invasive approach with unprecedented potential for (i) bridging antioxidant treatment in animal models and patients, (ii) identifying tissue subregions exhibiting oxidative stress, and (iii) coupling oxidative stress localization with behavioral dysfunction, disease pathology, and genetic vulnerabilities to serve as a marker of susceptibility.

  17. A clinical study of gated simultaneous rest 201Tl/stress 99Tcm-sestamibi dual isotope myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Tang Anwu; Qiao Shuixian; Luo Yaowu; Liang Xiaolin

    2002-01-01

    Objective: To investigate a modified gated radionuclide myocardial tomography in methodology for raising the sensitivity and efficiency of detecting myocardial ischemia. Methods: One hundred and three patients were involved and divided into two groups: coronary artery disease (CAD) patient 37, non-CAD patient 66. 201 Tl 111 MBq was injected intravenously 5 min before stress, the patient exercised with ergometer following the modified Bruce protocol, and was injected 99 Tc m -sestamibi at the peak of stress. 45 min later, the simultaneous dual energy peak gated acquisition was then performed. Stress ( 99 Tc m -sestamibi) and rest ( 201 Tl) images were reconstructed. Results: Positive findings were seen in 35/37 (94.6%) in CAD group and 7/66 (10.6%) in non-CAD, respectively; LVEF, EDV and ESV of two groups were (52.33+-16.26)%, (70.45+-28.12) mL, (33.35 +- 18.86) mL and (61.76 +- 9.38)%, (60.45 +- 18.18) mL, (23.30 +- 11.09) mL, respectively. Conclusion: The simultaneous stress ( 99 Tc m -sestamibi) and rest ( 201 Tl) gated myocardial imaging is an efficient and practical protocol for the study of myocardial perfusion and the diagnosis of ischemia

  18. Prospective evaluation of a new protocol for the provisional use of perfusion imaging with exercise stress testing

    Energy Technology Data Exchange (ETDEWEB)

    Duvall, W.L. [Hartford Hospital, Division of Cardiology (Henry Low Heart Center), Hartford, CT (United States); Mount Sinai Medical Center, Division of Cardiology (Mount Sinai Heart), New York, NY (United States); Savino, John A.; Levine, Elliot J.; Croft, Lori B.; Henzlova, Milena J. [Mount Sinai Medical Center, Division of Cardiology (Mount Sinai Heart), New York, NY (United States); Hermann, Luke K. [Mount Sinai Medical Center, Department of Emergency Medicine, New York, NY (United States)

    2014-11-04

    Previous literature suggests that myocardial perfusion imaging (MPI) adds little to the prognosis of patients who exercise >10 metabolic equivalents (METs) during stress testing. With this in mind, we prospectively tested a provisional injection protocol in emergency department (ED) patients presenting for the evaluation of chest pain in which a patient would not receive an injection of radioisotope if adequate exercise was achieved without symptoms and a negative ECG response. All patients who presented to the ED over a 5-year period who were referred for stress testing as part of their ED evaluation were included. Patients considered for a provisional protocol were: exercise stress, age <65 years, no known coronary artery disease, and an interpretable rest ECG. Criteria for not injecting included a maximal predicted heart rate ≥85 %, ≥10 METs of exercise, no anginal symptoms during stress, and no ECG changes. Groups were compared based on stress test results, all-cause and cardiac mortality, follow-up cardiac testing, subsequent revascularization, and cost. A total of 965 patients were eligible with 192 undergoing exercise-only and 773 having perfusion imaging. After 41.6 ± 19.6 months of follow-up, all-cause mortality was similar in the exercise-only versus the exercise plus imaging group (2.6 % vs. 2.1 %, p = 0.59). There were no cardiac deaths in the exercise-only group. At 1 year there was no difference in the number of repeat functional stress tests (1.6 % vs. 2.1 %, p = 0.43), fewer angiograms (0 % vs. 4.0 %, p = 0.002), and a significantly lower cost (65 ± 332 vs 506 ± 1,991, p = 0.002; values are in US dollars) in the exercise-only group. The radiation exposure in the exercise plus imaging group was 8.4 ± 2.1 mSv. A provisional injection protocol has a very low mortality, few follow-up diagnostic tests, and lower cost compared to standard imaging protocols. If adopted it would decrease radiation exposure, save time and decrease health-care costs

  19. Prospective evaluation of a new protocol for the provisional use of perfusion imaging with exercise stress testing.

    Science.gov (United States)

    Duvall, W Lane; Savino, John A; Levine, Elliot J; Hermann, Luke K; Croft, Lori B; Henzlova, Milena J

    2015-02-01

    Previous literature suggests that myocardial perfusion imaging (MPI) adds little to the prognosis of patients who exercise >10 metabolic equivalents (METs) during stress testing. With this in mind, we prospectively tested a provisional injection protocol in emergency department (ED) patients presenting for the evaluation of chest pain in which a patient would not receive an injection of radioisotope if adequate exercise was achieved without symptoms and a negative ECG response. All patients who presented to the ED over a 5-year period who were referred for stress testing as part of their ED evaluation were included. Patients considered for a provisional protocol were: exercise stress, age heart rate ≥85%, ≥10 METs of exercise, no anginal symptoms during stress, and no ECG changes. Groups were compared based on stress test results, all-cause and cardiac mortality, follow-up cardiac testing, subsequent revascularization, and cost. A total of 965 patients were eligible with 192 undergoing exercise-only and 773 having perfusion imaging. After 41.6 ± 19.6 months of follow-up, all-cause mortality was similar in the exercise-only versus the exercise plus imaging group (2.6% vs. 2.1%, p = 0.59). There were no cardiac deaths in the exercise-only group. At 1 year there was no difference in the number of repeat functional stress tests (1.6% vs. 2.1%, p = 0.43), fewer angiograms (0% vs. 4.0%, p = 0.002), and a significantly lower cost ($65 ± $332 vs $506 ± $1,991, p = 0.002; values are in US dollars) in the exercise-only group. The radiation exposure in the exercise plus imaging group was 8.4 ± 2.1 mSv. A provisional injection protocol has a very low mortality, few follow-up diagnostic tests, and lower cost compared to standard imaging protocols. If adopted it would decrease radiation exposure, save time and decrease health-care costs without jeopardizing prognosis.

  20. Prospective evaluation of a new protocol for the provisional use of perfusion imaging with exercise stress testing

    International Nuclear Information System (INIS)

    Duvall, W.L.; Savino, John A.; Levine, Elliot J.; Croft, Lori B.; Henzlova, Milena J.; Hermann, Luke K.

    2015-01-01

    Previous literature suggests that myocardial perfusion imaging (MPI) adds little to the prognosis of patients who exercise >10 metabolic equivalents (METs) during stress testing. With this in mind, we prospectively tested a provisional injection protocol in emergency department (ED) patients presenting for the evaluation of chest pain in which a patient would not receive an injection of radioisotope if adequate exercise was achieved without symptoms and a negative ECG response. All patients who presented to the ED over a 5-year period who were referred for stress testing as part of their ED evaluation were included. Patients considered for a provisional protocol were: exercise stress, age <65 years, no known coronary artery disease, and an interpretable rest ECG. Criteria for not injecting included a maximal predicted heart rate ≥85 %, ≥10 METs of exercise, no anginal symptoms during stress, and no ECG changes. Groups were compared based on stress test results, all-cause and cardiac mortality, follow-up cardiac testing, subsequent revascularization, and cost. A total of 965 patients were eligible with 192 undergoing exercise-only and 773 having perfusion imaging. After 41.6 ± 19.6 months of follow-up, all-cause mortality was similar in the exercise-only versus the exercise plus imaging group (2.6 % vs. 2.1 %, p = 0.59). There were no cardiac deaths in the exercise-only group. At 1 year there was no difference in the number of repeat functional stress tests (1.6 % vs. 2.1 %, p = 0.43), fewer angiograms (0 % vs. 4.0 %, p = 0.002), and a significantly lower cost (65 ± 332 vs 506 ± 1,991, p = 0.002; values are in US dollars) in the exercise-only group. The radiation exposure in the exercise plus imaging group was 8.4 ± 2.1 mSv. A provisional injection protocol has a very low mortality, few follow-up diagnostic tests, and lower cost compared to standard imaging protocols. If adopted it would decrease radiation exposure, save time and decrease health-care costs

  1. Hepatic necro-inflammation and elevated liver enzymes: Evaluation with MRI perfusion imaging with gadoxetic acid in chronic hepatitis patients

    International Nuclear Information System (INIS)

    Chen, B.-B.; Hsu, C.-Y.; Yu, C.-W.; Kao, J.-H.; Lee, H.-S.; Liang, P.-C.; Wei, S.-Y.; Hwang, R.-M.; Shih, T.T.-F.

    2014-01-01

    Aim: To evaluate liver necro-inflammation and function by using gadoxetic acid-enhanced dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), with histological analysis as the reference standard. Materials and methods: Seventy-nine subjects (21 healthy subjects; 58 chronic hepatitis patients) who received gadoxetic acid-enhanced DCE-MRI were divided into three subgroups: no (A0, n = 31), mild (A1, n = 27), and moderate–severe (A2–A3, n = 21) activities. Two DCE-MRI models were measured: (1) a dual-input single-compartment model to obtain absolute arterial, portal venous, and total blood flow, arterial fraction (ART), distribution volume, and mean transit time; (2) a curve analysis method to obtain peak, slope, and AUC (area under curve). The serum alanine aminotransferase (ALT) and aspartate aminotransferase (AST) levels also obtained. Statistical testing included Kruskal–Wallis tests for continuous data, Pearson's correlation tests, and multiple linear regression analyses. Results: Hepatic necro-inflammatory activity grades were significantly correlated with fibrotic stages, serum ALT level, ART and AUC. ART was helpful to predict the mild activity (≤A1 versus >A1; Az = 0.728), whereas AUC could differentiate no activity from any activity (A0 versus >A0; Az = 0.703). Peak, slope and AUC were all associated with AST and ALT (p < 0.05). Conclusion: Gadoxetic acid-enhanced DCE-MRI parameters may be used to evaluate the severity of hepatic necro-inflammation and function

  2. Rest-Stress Limb Perfusion Imaging in Humans with Contrast Ultrasound Using Intermediate-Power Imaging and Microbubbles Resistant to Inertial Cavitation.

    Science.gov (United States)

    Davidson, Brian P; Hodovan, James; Belcik, J Todd; Moccetti, Federico; Xie, Aris; Ammi, Azzdine Y; Lindner, Jonathan R

    2017-05-01

    Contrast-enhanced ultrasound (CEU) limb perfusion imaging is a promising approach for evaluating peripheral artery disease (PAD). However, low signal enhancement in skeletal muscle has necessitated high-power intermittent imaging algorithms, which are not clinically feasible. We hypothesized that CEU using a combination of intermediate power and a contrast agent resistant to inertial cavitation would allow real-time limb stress perfusion imaging. In normal volunteers, CEU of the calf skeletal muscle was performed on separate days with Sonazoid, Optison, or Definity. Progressive reduction in the ultrasound pulsing interval was used to assess the balance between signal enhancement and agent destruction at escalating mechanical indices (MI, 0.1-0.4). Real-time perfusion imaging at MI 0.1-0.4 using postdestructive replenishment kinetics was performed at rest and during 25 W plantar flexion contractile exercise. For Optison, limb perfusion imaging was unreliable at rest due to very low signal enhancement generated at all MIs and was possible during exercise-induced hyperemia only at MI 0.1 due to agent destruction at higher MIs. For Definity, signal intensity progressively increased with MI but was offset by microbubble destruction, which resulted in modest signal enhancement during CEU perfusion imaging and distortion of replenishment curves at MI ≥ 0.2. For Sonazoid, there strong signal enhancement at MI ≥ 0.2, with little destruction detected only at MI 0.4. Accordingly, high signal intensity and nondistorted perfusion imaging was possible at MI 0.2-0.3 and detected an 8.0- ± 5.7-fold flow reserve. Rest-stress limb perfusion imaging in humans with real-time CEU, which requires only seconds to perform, is possible using microbubbles with viscoelastic properties that produce strong nonlinear signal generation without destruction at intermediate acoustic pressures. Copyright © 2016 American Society of Echocardiography. All rights reserved.

  3. Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols

    International Nuclear Information System (INIS)

    Verger, Antoine; Karcher, Gilles; Djaballah, Wassila; Fourquet, Nicolas; Rouzet, Francois; Le Guludec, Dominique; Koehl, Gregoire; Roch, Veronique; Imbert, Laetitia; Poussier, Sylvain; Fay, Renaud; Marie, Pierre-Yves

    2013-01-01

    The results of stress myocardial perfusion SPECT could be enhanced by new cadmium-zinc-telluride (CZT) cameras, although differences compared to the results with conventional Anger cameras remain poorly known for most study protocols. This study was aimed at comparing the results of CZT and Anger SPECT according to various study protocols while taking into account the influence of obesity. The study population, which was from three different institutions equipped with identical CZT cameras, comprised 276 patients referred for study using protocols involving 201 Tl (n = 120) or 99m Tc-sestamibi injected at low dose at stress ( 99m Tc-Low; stress/rest 1-day protocol; n = 110) or at high dose at stress ( 99m Tc-High; rest/stress 1-day or 2-day protocol; n = 46). Each Anger SPECT scan was followed by a high-speed CZT SPECT scan (2 to 4 min). Agreement rates between CZT and Anger SPECT were good irrespective of the study protocol (for abnormal SPECT, 201 Tl 92 %, 99m Tc-Low 86 %, 99m Tc-High 98 %), although quality scores were much higher for CZT SPECT with all study protocols. Overall correlations were high for the extent of myocardial infarction (r = 0.80) and a little lower for ischaemic areas (r = 0.72), the latter being larger on Anger SPECT (p 201 Tl or 99m Tc-Low group and in whom stress myocardial counts were particularly low with Anger SPECT (228 ± 101 kcounts) and dramatically enhanced with CZT SPECT (+279 ± 251 %). Concordance between the results of CZT and Anger SPECT is good regardless of study protocol and especially when excluding obese patients who have low-count Anger SPECT and for whom myocardial counts are dramatically enhanced on CZT SPECT. (orig.)

  4. Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols

    Energy Technology Data Exchange (ETDEWEB)

    Verger, Antoine; Karcher, Gilles [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); INSERM U947, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Djaballah, Wassila [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); INSERM U947, Nancy (France); Fourquet, Nicolas [Clinique Pasteur, Toulouse (France); Rouzet, Francois; Le Guludec, Dominique [AP-HP, Hopital Bichat, Department of Nuclear Medicine, Paris (France); INSERM U 773 Inserm and Denis Diderot University, Paris (France); Koehl, Gregoire; Roch, Veronique [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Imbert, Laetitia [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Centre Alexis Vautrin, Department of Radiotherapy, Vandoeuvre (France); Poussier, Sylvain [INSERM U947, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Fay, Renaud [INSERM, Centre d' Investigation Clinique CIC-P 9501, Nancy (France); Marie, Pierre-Yves [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); INSERM U961, Nancy (France); Hopital de Brabois, CHU-Nancy, Medecine Nucleaire, Vandoeuvre-les-Nancy (France)

    2013-03-15

    The results of stress myocardial perfusion SPECT could be enhanced by new cadmium-zinc-telluride (CZT) cameras, although differences compared to the results with conventional Anger cameras remain poorly known for most study protocols. This study was aimed at comparing the results of CZT and Anger SPECT according to various study protocols while taking into account the influence of obesity. The study population, which was from three different institutions equipped with identical CZT cameras, comprised 276 patients referred for study using protocols involving {sup 201}Tl (n = 120) or {sup 99m}Tc-sestamibi injected at low dose at stress ({sup 99m}Tc-Low; stress/rest 1-day protocol; n = 110) or at high dose at stress ({sup 99m}Tc-High; rest/stress 1-day or 2-day protocol; n = 46). Each Anger SPECT scan was followed by a high-speed CZT SPECT scan (2 to 4 min). Agreement rates between CZT and Anger SPECT were good irrespective of the study protocol (for abnormal SPECT, {sup 201}Tl 92 %, {sup 99m}Tc-Low 86 %, {sup 99m}Tc-High 98 %), although quality scores were much higher for CZT SPECT with all study protocols. Overall correlations were high for the extent of myocardial infarction (r = 0.80) and a little lower for ischaemic areas (r = 0.72), the latter being larger on Anger SPECT (p < 0.001). This larger extent was mainly observed in 50 obese patients who were in the {sup 201}Tl or {sup 99m}Tc-Low group and in whom stress myocardial counts were particularly low with Anger SPECT (228 {+-} 101 kcounts) and dramatically enhanced with CZT SPECT (+279 {+-} 251 %). Concordance between the results of CZT and Anger SPECT is good regardless of study protocol and especially when excluding obese patients who have low-count Anger SPECT and for whom myocardial counts are dramatically enhanced on CZT SPECT. (orig.)

  5. Evaluation of femoral perfusion using dynamic contrast-enhanced MRI after simultaneous initiation of electrical stimulation and steroid treatment in an osteonecrosis model.

    Science.gov (United States)

    Yamamoto, Hiroki; Ueshima, Keiichiro; Saito, Masazumi; Ikoma, Kazuya; Ishida, Masashi; Goto, Tsuyoshi; Hayashi, Shigeki; Ikegami, Akira; Fujioka, Mikihiro; Mazda, Osam; Kubo, Toshikazu

    2018-04-30

    This study aimed to evaluate femoral perfusion using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) for two weeks after the simultaneous initiation of electrical stimulation (ES) and steroid treatment in a steroid-induced osteonecrosis (ON) model. A single dose of methylprednisolone was injected into 14 rabbits. Seven rabbits underwent ES (ES group), and seven rabbits did not (control group). DCE-MRI was performed before steroid administration and 1, 5, 10, and 14 days after steroid administration. Regions of interest were set in the bilateral proximal femora. The enhancement ratio, initial slope, and area under the curve were analyzed. These parameters were evaluated after steroid administration in each group and between the two groups, and the ratios of ON in both groups were compared. In the control group, the minimum values of all parameters decreased significantly after steroid administration (P < 0.05), but in the ES group, the parameters did not decrease. In the ES group, all parameter values were significantly increased on the 10th and 14th days (P < 0.05). All parameter values in the ES group were significantly higher than those in the control group on the 14th day (P < 0.05). In the control group, ON was detected in three of five rabbits (in three of ten femora). In the ES group, ON was not detected. These results suggest that increased femoral blood flow elicited by ES may be related to ON prevention after steroid administration.

  6. Measurement of the arterial concentration of Gd-DTPA using MRI: a step toward quantitative perfusion imaging

    DEFF Research Database (Denmark)

    Fritz-Hansen, T; Rostrup, Egill; Larsson, H B

    1996-01-01

    A noninvasive method using an inversion recovery turbo-FLASH for dynamic measurement of the arterial input function represented by the bolus passage of Gd-DTPA in the descending aorta is presented, and the results are compared with the input function obtained by arterial blood samples. A good...... accordance between the two input functions was found, indicating that it is possible to measure the input function to the myocardium using MRI. A variation between the two concentration curves of 5% at upslope, 2.7% at peak point, and ... inversion time peak concentration....

  7. Comparison of exercise and pharmacologic stress in myocardium perfusion imaging for CHD

    International Nuclear Information System (INIS)

    Li Zebo; Zheng Kangni; Cheng Xiaorui; Liu Hui; Cheng Yihai

    1995-01-01

    In order to provide a proper stress test, exercise, dipyridamole and ATP stress were compared. Three modalities were compared with respect to the detecting rate, methodology, hemodynamic and side effects. There are no significant differences in their ability of detecting coronary heart disease (CHD) (P>0.05). Exercise stress causes an increase in heart rate, blood pressure and myocardium oxygen consumption. Pharmacologic stress cause a slight increase in heart rate, but a decrease in blood pressure (P<0.01). Exercise stress is a basic method with good image quality, but it needs a special equipment. Pharmacologic stress is an easier, cheaper and safer method, particularly useful for patients unable to perform exercise test

  8. Grading and outcome prediction of pediatric diffuse astrocytic tumors with diffusion and arterial spin labeling perfusion MRI in comparison with 18F-DOPA PET

    Energy Technology Data Exchange (ETDEWEB)

    Morana, Giovanni; Tortora, Domenico; Severino, Mariasavina; Rossi, Andrea [Istituto Giannina Gaslini, Neuroradiology Unit, Genoa (Italy); Piccardo, Arnoldo; Cabria, Manlio [Ente Ospedaliero Ospedali Galliera, Nuclear Medicine Unit, Genoa (Italy); Puntoni, Matteo [Ente Ospedaliero Ospedali Galliera, Clinical Trial Unit, Scientific Directorate, Genoa (Italy); Nozza, Paolo [Istituto Giannina Gaslini, Pathology Unit, Genoa (Italy); Ravegnani, Marcello; Consales, Alessandro; Mascelli, Samantha; Raso, Alessandro [Istituto Giannina Gaslini, Neurosurgery Unit, Genoa (Italy); Verrico, Antonio; Milanaccio, Claudia [Istituto Giannina Gaslini, Neuro-oncology Unit, Genoa (Italy)

    2017-11-15

    The aim of this study was to investigate MRI-derived diffusion weighted imaging (DWI) and arterial spin labeling (ASL) perfusion imaging in comparison with {sup 18}F-dihydroxyphenylalanine (DOPA) PET with respect to diagnostic performance in tumor grading and outcome prediction in pediatric patients with diffuse astrocytic tumors (DAT). We retrospectively analyzed 26 children with histologically proven treatment naive low and high grade DAT who underwent ASL and DWI performed within 2 weeks of {sup 18}F-DOPA PET. Relative ASL-derived cerebral blood flow max (rCBF max) and DWI-derived minimum apparent diffusion coefficient (rADC min) were compared with {sup 18}F-DOPA uptake tumor/normal tissue (T/N) and tumor/striatum (T/S) ratios, and correlated with World Health Organization (WHO) tumor grade and progression-free survival (PFS). Statistics included Pearson's chi-square and Mann-Whitney U tests, Spearman's rank correlation, receiver operating characteristic (ROC) analysis, discriminant function analysis (DFA), Kaplan-Meier survival curve, and Cox analysis. A significant correlation was demonstrated between rCBF max, rADC min, and {sup 18}F-DOPA PET data (p < 0.001). Significant differences in terms of rCBF max, rADC min, and {sup 18}F-DOPA uptake were found between low- and high-grade DAT (p ≤ 0.001). ROC analysis and DFA demonstrated that T/S and T/N values were the best parameters for predicting tumor progression (AUC 0.93, p < 0.001). On univariate analysis, all diagnostic tools correlated with PFS (p ≤ 0.001); however, on multivariate analysis, only {sup 18}F-DOPA uptake remained significantly associated with outcome (p ≤ 0.03), while a trend emerged for rCBF max (p = 0.09) and rADC min (p = 0.08). The combination of MRI and PET data increased the predictive power for prognosticating tumor progression (AUC 0.97, p < 0.001). DWI, ASL and {sup 18}F-DOPA PET provide useful complementary information for pediatric DAT grading. {sup 18}F-DOPA uptake

  9. MRI

    DEFF Research Database (Denmark)

    Schroeter, Aileen; Rudin, Markus; Gianolio, Eliana

    2017-01-01

    This chapter discusses principles of nuclear magnetic resonance (NMR) and MRI followed by a survey on the major classes of MRI contrast agents (CA), their modes of action, and some of the most significative applications. The two more established classes of MRI-CA are represented by paramagnetic...... been attained that markedly increase the number and typology of systems with CEST properties. Currently much attention is also devoted to hyperpolarized molecules that display a sensitivity enhancement sufficient for their direct exploitation for the formation of the MR image. A real breakthrough...

  10. MRI

    Science.gov (United States)

    ... the room. Pins, hairpins, metal zippers, and similar metallic items can distort the images. Removable dental work ... an MRI can cause heart pacemakers and other implants not to work as well. The magnets can ...

  11. Comparison of exercise electrocardiography and stress perfusion CMR for the detection of coronary artery disease in women

    Directory of Open Access Journals (Sweden)

    Greulich Simon

    2012-06-01

    Full Text Available Abstract Background Exercise electrocardiography (ECG is frequently used in the work-up of patients with suspected coronary artery disease (CAD, however the accuracy is reduced in women. Cardiovascular magnetic resonance (CMR stress testing can accurately diagnose CAD in women. To date, a direct comparison of CMR to ECG has not been performed. Methods and results We prospectively enrolled 88 consecutive women with chest pain or other symptoms suggestive of CAD. Patients underwent a comprehensive clinical evaluation, exercise ECG, a CMR stress test including perfusion and infarct imaging, and x-ray coronary angiography (CA within 24 hours. CAD was defined as stenosis ≥70% on quantitative analysis of CA. Exercise ECG, CMR and CA was completed in 68 females (age 66.4 ± 8.8 years, number of CAD risk factors 3.5 ± 1.4. The prevalence of CAD on CA was 29%. The Duke treadmill score (DTS in the entire group was −3.0 ± 5.4 and was similar in those with and without CAD (−4.5 ± 5.8 and −2.4 ± 5.1; P = 0.12. Sensitivity, specificity and accuracy for CAD diagnosis was higher for CMR compared with exercise ECG (sensitivities 85% and 50%, P = 0.02, specificities 94% and 73%, P = 0.01, and accuracies 91% and 66%, P = 0.0007, respectively. Even after applying the DTS the accuracy of CMR was higher compared to exercise ECG (area under ROC curve 0.94 ± 0.03 vs 0.56 ± 0.07; P = 0.0001. Conclusions In women with intermediate-to-high risk for CAD who are able to exercise and have interpretable resting ECG, CMR stress perfusion imaging has higher accuracy for the detection of relevant obstruction of the epicardial coronaries when directly compared to exercise ECG.

  12. Volumetric Arterial Wall Shear Stress Calculation Based on Cine Phase Contrast MRI

    NARCIS (Netherlands)

    Potters, Wouter V.; van Ooij, Pim; Marquering, Henk; VanBavel, Ed; Nederveen, Aart J.

    2015-01-01

    PurposeTo assess the accuracy and precision of a volumetric wall shear stress (WSS) calculation method applied to cine phase contrast magnetic resonance imaging (PC-MRI) data. Materials and MethodsVolumetric WSS vectors were calculated in software phantoms. WSS algorithm parameters were optimized

  13. Detection of myocardial stunning with gated SPECT and its relationship with location, extension and severity of perfusion defects induced by exercise or pharmacologic stress

    International Nuclear Information System (INIS)

    Mut, F.; Beretta, M.; Vidal, I.; Rener, A.; Alonso, O.

    2002-01-01

    Aim: To investigate the relationship between transient ventricular dysfunction detected by gated SPECT with the location, extension and severity of ischemic areas in patients with reversible perfusion defects. Material and Methods: We retrospectively studied 83 patients (61±11 yrs., 61 men, 27 with previous MI) submitted for coronary artery disease (CAD) evaluation with 99mTc-MIBI gated SPECT using a 2-day protocol whose perfusion imaging pattern had been reported positive for myocardial ischemia. Stress test was exercise in 54 cases, dipyridamole in 28 and dobutamine in 1. Previous work from our group demonstrated up to 12% change in LVEF from rest to post-stress in a population with low likelihood of CAD and a normal perfusion pattern. Thus, according to % variation of left ventricular ejection fraction (LVEF) from rest to post-stress we further divided the population into 2 subgroups, (A) with less than 12% change in LVEF (n=56) and (B) with more than 12% negative variation (n=27). For evaluation of perfusion, a simplified 7-segment division of the myocardium was used and a combined ischemic score was obtained by multiplying the number of segments with reversible defects by the 1-4 assigned severity score. Results: There was no significant difference between the two groups regarding age, gender, stress result (clinical or ECG), number of fixed perfusion defects or rest LVEF. Dipyridamole test was more frequent among patients of group B. Post-stress LVEF was 49±14% for group A and 41±15% for group B, p=0.0125. Combined ischemic score was 6.82±6.5 vs. 11.96±12 respectively, p=0.014. In patients of group A, defects corresponding to the right coronary territory were more frequent, while the left descending artery territory was more commonly affected in group B patients, however this was not statistically significant. Left circumflex territory was equally affected in both groups. Conclusion: Transient ventricular dysfunction after a stress test can be

  14. Environmental heat stress enhances mental fatigue during sustained attention task performing: evidence from an ASL perfusion study.

    Science.gov (United States)

    Qian, Shaowen; Li, Min; Li, Guoying; Liu, Kai; Li, Bo; Jiang, Qingjun; Li, Li; Yang, Zhen; Sun, Gang

    2015-03-01

    This study was to investigate the potential enhancing effect of heat stress on mental fatigue progression during sustained attention task using arterial spin labeling (ASL) imaging. Twenty participants underwent two thermal exposures in an environmental chamber: normothermic (NT) condition (25°C, 1h) and hyperthermic (HT) condition (50°C, 1h). After thermal exposure, they performed a twenty-minute psychomotor vigilance test (PVT) in the scanner. Behavioral analysis revealed progressively increasing subjective fatigue ratings and reaction time as PVT progressed. Moreover, heat stress caused worse performance. Perfusion imaging analyses showed significant resting-state cerebral blood flow (CBF) alterations after heat exposure. Specifically, increased CBF mainly gathered in thalamic-brainstem area while decreased CBF predominantly located in fronto-parietal areas, anterior cingulate cortex, posterior cingulate cortex, and medial frontal cortex. More importantly, diverse CBF distributions and trend of changes between both conditions were observed as the fatigue level progressed during subsequent PVT task. Specifically, higher CBF and enhanced rising trend were presented in superior parietal lobe, precuneus, posterior cingulate cortex and anterior cingulate cortex, while lower CBF or inhibited rising trend was found in dorsolateral frontal cortex, medial frontal cortex, inferior parietal lobe and thalamic-brainstem areas. Furthermore, the decrease of post-heat resting-state CBF in fronto-parietal cortex was correlated with subsequent slower reaction time, suggesting prior disturbed resting-state CBF might be indicator of performance potential and fatigue level in following task. These findings may provide proof for such a view: heat stress has a potential fatigue-enhancing effect when individual is performing highly cognition-demanding attention task. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Manubrial stress fractures diagnosed on MRI: report of two cases and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Jonathan C.; Demertzis, Jennifer L. [Washington University School of Medicine, Mallinckrodt Institute of Radiology, Musculoskeletal Section, St Louis, MO (United States)

    2016-06-15

    In contrast to widely-reported sternal insufficiency fractures, stress fractures of the sternum from overuse are extremely rare. Of the 5 cases of sternal stress fracture published in the English-language medical literature, 3 were in the sternal body and only 2 were in the manubrium. We describe two cases of manubrial stress fracture related to golf and weightlifting, and present the first report of the MR findings of this injury. In each of these cases, the onset of pain was atraumatic, insidious, and associated with increased frequency of athletic activity. Imaging was obtained because of clinical diagnostic uncertainty. On MRI, each patient had a sagittally oriented stress fracture of the lateral manubrium adjacent to the first rib synchondrosis. Both patients had resolution of pain after a period of rest, with subsequent successful return to their respective activities. One patient had a follow-up MRI, which showed resolution of the manubrial marrow edema and fracture line. Based on the sternal anatomy and MR findings, we hypothesize that this rare injury might be caused by repetitive torque of the muscle forces on the first costal cartilage and manubrium, and propose that MRI might be an effective means of diagnosing manubrial stress fracture. (orig.)

  16. Manubrial stress fractures diagnosed on MRI: report of two cases and review of the literature

    International Nuclear Information System (INIS)

    Baker, Jonathan C.; Demertzis, Jennifer L.

    2016-01-01

    In contrast to widely-reported sternal insufficiency fractures, stress fractures of the sternum from overuse are extremely rare. Of the 5 cases of sternal stress fracture published in the English-language medical literature, 3 were in the sternal body and only 2 were in the manubrium. We describe two cases of manubrial stress fracture related to golf and weightlifting, and present the first report of the MR findings of this injury. In each of these cases, the onset of pain was atraumatic, insidious, and associated with increased frequency of athletic activity. Imaging was obtained because of clinical diagnostic uncertainty. On MRI, each patient had a sagittally oriented stress fracture of the lateral manubrium adjacent to the first rib synchondrosis. Both patients had resolution of pain after a period of rest, with subsequent successful return to their respective activities. One patient had a follow-up MRI, which showed resolution of the manubrial marrow edema and fracture line. Based on the sternal anatomy and MR findings, we hypothesize that this rare injury might be caused by repetitive torque of the muscle forces on the first costal cartilage and manubrium, and propose that MRI might be an effective means of diagnosing manubrial stress fracture. (orig.)

  17. Manubrial stress fractures diagnosed on MRI: report of two cases and review of the literature.

    Science.gov (United States)

    Baker, Jonathan C; Demertzis, Jennifer L

    2016-06-01

    In contrast to widely-reported sternal insufficiency fractures, stress fractures of the sternum from overuse are extremely rare. Of the 5 cases of sternal stress fracture published in the English-language medical literature, 3 were in the sternal body and only 2 were in the manubrium. We describe two cases of manubrial stress fracture related to golf and weightlifting, and present the first report of the MR findings of this injury. In each of these cases, the onset of pain was atraumatic, insidious, and associated with increased frequency of athletic activity. Imaging was obtained because of clinical diagnostic uncertainty. On MRI, each patient had a sagittally oriented stress fracture of the lateral manubrium adjacent to the first rib synchondrosis. Both patients had resolution of pain after a period of rest, with subsequent successful return to their respective activities. One patient had a follow-up MRI, which showed resolution of the manubrial marrow edema and fracture line. Based on the sternal anatomy and MR findings, we hypothesize that this rare injury might be caused by repetitive torque of the muscle forces on the first costal cartilage and manubrium, and propose that MRI might be an effective means of diagnosing manubrial stress fracture.

  18. [Diffusion weighted imaging and perfusion weighted imaging in the differential diagnosis of benign and malignant renal masses on 3.0 T MRI].

    Science.gov (United States)

    Xu, Xiaowen; Wang, Peijun; Ma, Liang; Shao, Zhihong; Zhang, Min

    2015-01-20

    To explore the value of diffusion weighted imaging (DWI) and perfusion weighted imaging (PWI) in identifying benign and malignant renal masses and differentiating the histological types of renal masses. Fifteen healthy volunteers and 46 patients with renal masses proven by pathology, including clear cell carcinomas (n = 18), papillary carcinomas (n = 8), chromophobe carcinomas (n = 7) and angiomyolipomas (n = 13), were examined with DWI and PWI scan at 3.0 T MRI. ANOVA was employed to compare the values of transfer constant (K(trans)), rate constant of backflux (Kep) and extra-vascular extra-cellular space fractional volume (Ve) proceeded by PWI and the value of ADC resulted from DWI between normal kidney and different histological types of renal masses. Receiver operating characteristics (ROC) curve was used to analyze and compare the diagnostic value of the methods of PWI and DWI in differentiating benign and malignant renal masses. The ADC value of normal renal parenchyma was (2.10 ± 0.24) × 10⁻³ mm²/s, which was statistically higher than benign and malignant renal masses (P 0.05).Values of K(trans), Kep and Ve between normal renal parenchyma and different histological types of renal masses had statistical differences.Values of K(trans) and Ve in three histological types of malignant renal masses were statistically higher than those of benign renal masses.Kep value of clear cell carcinoma was significantly higher than that of benign renal masses (P benign and malignant renal masses. The K(trans) of benign and malignant renal masses had the largest AUC (AUC = 0.937) at a threshold of 0.38/min. And there were a sensitivity of 87.9% and a specificity of 85.7%. The AUC of ADC was 0.823, sensitivity 72.7% and specificity 92.9%. The ADC threshold for differentiating benign from malignant masses was 1.40 × 10⁻³ mm²/s; AUC of Ve 0.803, sensitivity 78.8% and specificity 71.4%, a threshold of 0.29/min; Kep showed lower diagnostic value. 3.0 T MRI DWI and PWI

  19. Design and rationale of the MR-INFORM study: stress perfusion cardiovascular magnetic resonance imaging to guide the management of patients with stable coronary artery disease

    Directory of Open Access Journals (Sweden)

    Hussain Shazia T

    2012-09-01

    Full Text Available Abstract Background In patients with stable coronary artery disease (CAD, decisions regarding revascularisation are primarily driven by the severity and extent of coronary luminal stenoses as determined by invasive coronary angiography. More recently, revascularisation decisions based on invasive fractional flow reserve (FFR have shown improved event free survival. Cardiovascular magnetic resonance (CMR perfusion imaging has been shown to be non-inferior to nuclear perfusion imaging in a multi-centre setting and superior in a single centre trial. In addition, it is similar to invasively determined FFR and therefore has the potential to become the non-invasive test of choice to determine need for revascularisation. Trial design The MR-INFORM study is a prospective, multi-centre, randomised controlled non-inferiority, outcome trial. The objective is to compare the efficacy of two investigative strategies for the management of patients with suspected CAD. Patients presenting with stable angina are randomised into two groups: 1 The FFR-INFORMED group has subsequent management decisions guided by coronary angiography and fractional flow reserve measurements. 2 The MR-INFORMED group has decisions guided by stress perfusion CMR. The primary end-point will be the occurrence of major adverse cardiac events (death, myocardial infarction and repeat revascularisation at one year. Clinical trials.gov identifier NCT01236807. Conclusion MR INFORM will assess whether an initial strategy of CMR perfusion is non-inferior to invasive angiography supplemented by FFR measurements to guide the management of patients with stable coronary artery disease. Non-inferiority of CMR perfusion imaging to the current invasive reference standard (FFR would establish CMR perfusion imaging as an attractive non-invasive alternative to current diagnostic pathways.

  20. Volumetric assessment of recurrent or progressive gliomas: comparison between F-DOPA PET and perfusion-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Cicone, Francesco [Sant' Andrea Hospital, Rome (Italy). Unit of Nuclear Medicine; Rome Sapienza Univ. (Italy). Dept. of Surgical and Medical Sciences and tranlational Medicine; Research Centre Juelich (Germany). Inst. of Neureoscience and Medicine; Filss, Christian P.; Langen, Karl-Josef [Research Centre Juelich (Germany). Inst. of Neureoscience and Medicine; RWTH Aachen Univ. Hospital (Germany). Dept. of Nuclear Medicine; Minniti, Giuseppe; Scaringi, Claudia [Rome Sapienza Univ. (Italy). Dept. of Surgical and Medical Sciences and tranlational Medicine; Sant' Andrea Hospital, Rome (Italy). Unit of Radiotherapy; Rossi-Espagnet, Camilla; Bozzao, Alessandro [Sant' Andrea Hospital, Rome (Italy). Unit of Neuroradiology; Rome Sapienza Univ. (Italy). Dept. of Neurosciences, Mental Health and Sensory Organs (Ne.S.M.O.S.); Papa, Annalisa; Scopinaro, Francesco [Sant' Andrea Hospital, Rome (Italy). Unit of Nuclear Medicine; Rome Sapienza Univ. (Italy). Dept. of Surgical and Medical Sciences and tranlational Medicine; Galldiks, Norbert [Research Centre Juelich (Germany). Inst. of Neureoscience and Medicine; Cologne Univ. (Germany). Dept. of Neurology; Shah, N. Jon [Research Centre Juelich (Germany). Inst. of Neureoscience and Medicine

    2015-05-01

    To compare the diagnostic information obtained with 6-[{sup 18}F]-fluoro-l-3,4-dihydroxyphenylalanine (F-DOPA) PET and relative cerebral blood volume (rCBV) maps in recurrent or progressive glioma. All patients with recurrent or progressive glioma referred for F-DOPA imaging at our institution between May 2010 and May 2014 were retrospectively included, provided that macroscopic disease was visible on conventional MRI images and that rCBV maps were available for comparison. The final analysis included 50 paired studies (44 patients). After image registration, automatic tumour segmentation of both sets of images was performed using the average signal in a large reference VOI including grey and white matter multiplied by 1.6. Tumour volumes identified by both modalities were compared and their spatial congruence calculated. The distances between F-DOPA uptake and rCBV hot spots, tumour-to-brain ratios (TBRs) and normalized histograms were also computed. On visual inspection, 49 of the 50 F-DOPA and 45 of the 50 rCBV studies were classified as positive. The tumour volume delineated using F-DOPA (F-DOPA{sub vol} {sub 1.6}) greatly exceeded that of rCBV maps (rCBV{sub vol} {sub 1.6}). The median F-DOPA{sub vol} {sub 1.6} and rCBV{sub vol} {sub 1.6} were 11.44 ml (range 0 - 220.95 ml) and 1.04 ml (range 0 - 26.30 ml), respectively (p < 0.00001). Overall, the median overlapping volume was 0.27 ml, resulting in a spatial congruence of 1.38 % (range 0 - 39.22 %). The mean hot spot distance was 27.17 mm (±16.92 mm). F-DOPA uptake TBR was significantly higher than rCBV TBR (1.76 ± 0.60 vs. 1.15 ± 0.52, respectively; p < 0.0001). The histogram analysis showed that F-DOPA provided better separation of tumour from background. In 6 of the 50 studies (12 %), however, physiological uptake in the striatum interfered with tumour delineation. The information provided by F-DOPA PET and rCBV maps are substantially different. Image interpretation is easier and a larger tumour extent

  1. Determinants of the response of left ventricular ejection fraction to vasodilator stress in electrocardiographically gated {sup 82}rubidium myocardial perfusion PET

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Tracy L.Y.; Merrill, Jennifer; Bengel, Frank M. [Johns Hopkins University, Department of Radiology and Radiological Sciences, Division of Nuclear Medicine, Baltimore, MD (United States); Volokh, Lana [GE Healthcare, Haifa (Israel)

    2008-02-15

    Myocardial perfusion imaging with {sup 82}Rb PET allows for ECG-gated studies to be obtained early after radiotracer injection, capturing ventricular function close to peak pharmacologic action of dipyridamole. This is different from gated SPECT and may potentially provide additional diagnostic information. We sought to identify potential correlates of the PET-derived ejection fraction response to vasodilator stress. One hundred ten consecutive patients undergoing {sup 82}Rb PET myocardial perfusion imaging during evaluation for coronary artery disease were included. Using a GE Discovery STRx PET-CT scanner, ECG-gated images (eight bins) were obtained at rest and 4 min after dipyridamole infusion, 90 s after infusion of 1,480-2,220 MBq of {sup 82}Rb. Summed rest, stress, and difference scores (SRS, SSS, and SDS) were determined using a five-point scoring system and 20-segment model. Ejection fraction was calculated using automated QGS software. Significant reversibility (SDS {>=} 4) was found in 23 patients (21%). Mean LVEF in all patients was 47 {+-} 13% at rest and 53 {+-} 13% during dipyridamole. LVEF increased in 89 patients, and decreased in 17 patients during vasodilation. The change in LVEF was inversely correlated with SDS (r = -0.26; p = 0.007). Additionally, it was inversely correlated with resting LVEF (r = -0.20; p = 0.03) and SSS (r = -0.25; p = 0.009). No significant correlations were observed with SRS, heart rate, blood pressure, age, hypertension, hypercholesterolemia, or pretest likelihood of disease. At multivariate regression analysis, SDS was an independent predictor of the change in LVEF. Gated {sup 82}Rb PET during pharmacologic stress allows for assessment of the functional response to vasodilation. The magnitude of LVEF increase is determined by stress perfusion/reversible perfusion defects. Functional response to hyperemia may thus be incorporated in future evaluations of diagnostic and prognostic algorithms based on {sup 82}Rb PET. (orig.)

  2. Incremental value of contrast myocardial perfusion to detect intermediate versus severe coronary artery stenosis during stress-echocardiography

    Directory of Open Access Journals (Sweden)

    Ugo Fabrizio

    2010-05-01

    Full Text Available Abstract Background We aimed to compare the incremental value of contrast myocardial perfusion imaging (MPI for the detection of intermediate versus severe coronary artery stenosis during dipyridamole-atropine echocardiography (DASE. Wall motion (WM assessment during stress-echocardiography demonstrates suboptimal sensitivity to detect coronary artery disease (CAD, particularly in patients with isolated intermediate (50%-70% coronary stenosis. Methods We performed DASE with MPI in 150 patients with a suspected chest pain syndrome who were given clinical indication to coronary angiography. Results and discussion When CAD was defined as the presence of a ≥50% stenosis, the addition of MPI increased sensitivity (+30% and decreased specificity (-14%, with a final increase in total diagnostic accuracy (+16%, p Conclusions The addition of MPI on top of WM analysis during DASE increases the diagnostic sensitivity to detect obstructive CAD, whatever its definition (≥50% or > 70% stenosis, but it is mainly driven by the sensitivity increase in the intermediate group (50%-70% stenosis. The total diagnostic accuracy increased only when defining CAD as ≥50% stenosis, since in patients with severe stenosis (> 70% the decrease in specificity is not counterbalanced by the minor sensitivity increase.

  3. Evaluation of initial uptake and redistribution on stress thallium-201 myocardial perfusion images in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Watanabe, Yoshihiko; Tonooka, Ichiroh; Kanaya, Tohru; Tsuiki, Kai; Yasui, Shouji.

    1984-01-01

    Stress thallium-201 myocardial perfusion imaging was performed on 29 patients with previous myocardial infarction and 29 patients with angina pectoris at exercise to evaluate thallium-201 kinetics in ischemic heart disease. Four views of thallium-201 images (right anterior oblique, antero-posterior, left anterior oblique and left lateral views) were obtained at 5 min after treadmill exercise with administration of 2 mCi of thallium-201 chloride (initial image) and at 3 hours later (delayed image). Myocardial images were divided into 6 segments (anterior, lateral, inferior, posterior, apical and septal segments) and initial uptake (IU) and redistribution index (RDI, the ratio of the maximal washout rate to a washout rate in each segment) were calculated in order to assess the relations of thallium-201 kinetics to wall motion abnormality and coronary artery stenosis. In myocardial infarction, IU and RDI were decreased in proportion to the severity of wall motion abnormality and coronary artery stenosis. Contrarily, in angina pectoris, IU was decreased but RDI was increased proportionally to the severity of coronary arterial stenosis. In conclusion, IU and redistribution of thallium-201 were affected essentially by both the grade of coronary arterial stenosis and the amount of residual viable heart muscle in patients with ischemic myocardial disease. (author)

  4. Relation between wall shear stress and carotid artery wall thickening MRI versus CFD

    DEFF Research Database (Denmark)

    Cibis, Merih; Potters, Wouter V.; Selwaness, Mariana

    2016-01-01

    Wall shear stress (WSS), a parameter associated with endothelial function, is calculated by computational fluid dynamics (CFD) or phase-contrast (PC) MRI measurements. Although CFD is common in WSS (WSSCFD) calculations, PC-MRI-based WSS (WSSMRI) is more favorable in population studies; since...... it is straightforward and less time consuming. However, it is not clear if WSSMRI and WSSCFD show similar associations with vascular pathology. Our aim was to test the associations between wall thickness (WT) of the carotid arteries and WSSMRI and WSSCFD. The subjects (n=14) with an asymptomatic carotid plaque who...... underwent MRI scans two times within 4 years of time were selected from the Rotterdam Study. We compared WSSCFD and WSSMRI at baseline and follow-up. Baseline WSSMRI and WSSCFD values were divided into 3 categories representing low, medium and high WSS tertiles. WT of each tertile was compared by a one...

  5. Induction of Inducible Nitric Oxide Synthase by Lipopolysaccharide and the Influences of Cell Volume Changes, Stress Hormones and Oxidative Stress on Nitric Oxide Efflux from the Perfused Liver of Air-Breathing Catfish, Heteropneustes fossilis.

    Directory of Open Access Journals (Sweden)

    Mahua G Choudhury

    Full Text Available The air-breathing singhi catfish (Heteropneustes fossilis is frequently being challenged by bacterial contaminants, and different environmental insults like osmotic, hyper-ammonia, dehydration and oxidative stresses in its natural habitats throughout the year. The main objectives of the present investigation were to determine (a the possible induction of inducible nitric oxide synthase (iNOS gene with enhanced production of nitric oxide (NO by intra-peritoneal injection of lipopolysaccharide (LPS (a bacterial endotoxin, and (b to determine the effects of hepatic cell volume changes due to anisotonicity or by infusion of certain metabolites, stress hormones and by induction of oxidative stress on production of NO from the iNOS-induced perfused liver of singhi catfish. Intra-peritoneal injection of LPS led to induction of iNOS gene and localized tissue specific expression of iNOS enzyme with more production and accumulation of NO in different tissues of singhi catfish. Further, changes of hydration status/cell volume, caused either by anisotonicity or by infusion of certain metabolites such as glutamine plus glycine and adenosine, affected the NO production from the perfused liver of iNOS-induced singhi catfish. In general, increase of hydration status/cell swelling due to hypotonicity caused decrease, and decrease of hydration status/cell shrinkage due to hypertonicity caused increase of NO efflux from the perfused liver, thus suggesting that changes in hydration status/cell volume of hepatic cells serve as a potent modulator for regulating the NO production. Significant increase of NO efflux from the perfused liver was also observed while infusing the liver with stress hormones like epinephrine and norepinephrine, accompanied with decrease of hydration status/cell volume of hepatic cells. Further, oxidative stress, caused due to infusion of t-butyl hydroperoxide and hydrogen peroxide separately, in the perfused liver of singhi catfish, resulted

  6. Myocardial kinetics of thallium-201 after stress in normal and perfusion-reduced canine myocardium

    International Nuclear Information System (INIS)

    Okada, R.D.

    1985-01-01

    Despite the emerging use of quantitative computer programs for assessing myocardial thallium uptake and clearance after exercise, little is known about the kinetics of thallium after exercise stress. Accordingly, 11 mongrel dogs with experimental left anterior descending coronary stenoses were given thallium during norepinephrine infusion to simulate exercise. The infusion was discontinued and thallium activity was monitored regionally using miniature radiation detectors for 3 hours. Heart rate, arterial pressure and double product all increased significantly during norepinephrine infusion. The mean fractional myocardial thallium clearance was lower (0.47 +/- 0.03 [+/- standard error of the mean]) for the stenosis zone than for the no-stenosis zone (0.57 +/- 0.03) (p less than 0.0001). The stress blood flow ratio (stenosis/no-stenosis zone = 0.27 +/- 0.06) was significantly lower than the final thallium activity ratio (0.68 +/- 0.07) (p less than 0.001), consistent with thallium redistribution occurring over the 3-hour period. Myocardial thallium activity in the stenosis zone peaked in a mean of 2.2 minutes, then washed out biexponentially with a final decay constant of 0.0035 +/- 0.0005 min-1. Myocardial thallium activity in the no-stenosis zone peaked within 1 minute in all dogs, then washed out biexponentially, with a final decay constant of 0.0043 +/- 0.0003 (p less than 0.001 compared with stenosis zone). In conclusion, fractional clearance of thallium can differentiate myocardium distal to a coronary artery stenosis from that supplied by a normal coronary vessel

  7. Contralateral thalamic hypoperfusion on brain perfusion SPECT

    International Nuclear Information System (INIS)

    Lee, Seok Mo; Bae, Sang Kyun; Yoo, Kyung Moo; Yum, Ha Yong

    2000-01-01

    Brain perfusion single photon emission computed tomography (SPECT) is useful for the localization of cerebrovascular lesion and sometimes reveals more definite lesion than radiologic imaging modality such as CT or MRI does. The purpose of this study was to evaluate the diagnostic usefulness of brain perfusion SPECT in patients with hemisensory impairment. Thirteen consecutive patients (M:F= 8:5, mean age = 48) who has hemisensory impairment were included. Brain perfusion SPECT was performed after intravenous injection of 1110 MBq of Tc-99m ECD. The images were obtained using a dual-head gamma camera with ultra-high resolution collimator. Semiquantitative analysis was performed after placing multiple ROIs on cerebral cortex, basal ganglia, thalamus and cerebellum. There were 10 patients with left hemisensory impairment and 3 patients with right-sided symptom. Only 2 patients revealed abnormal signal change in the thalamus on MRI. But brain perfusion SPECT showed decreased perfusion in the thalamus in 9 patients. Six patients among 10 patients with left hemisensory impairment revealed decreased perfusion in the contralateral thalamus on brain SPECT. The other 4 patients revealed no abnormality. Two patients among 3 patients with right hemisensory impairment also showed decreased perfusion in the contralateral thalamus on brain SPECT. One patients with right hemisensory impairment showed ipsilateral perfusion decrease. Two patients who had follow-up brain perfusion SEPCT after treatment revealed normalization of perfusion in the thalamus. Brain perfusion SPECT might be a useful tool in diagnosing patients with hemisensory impairment

  8. The influence of menstrual cycle and androstadienone on female stress reactions: an fMRI study.

    Directory of Open Access Journals (Sweden)

    Ka Chun eChung

    2016-02-01

    Full Text Available Communicating threats and stress via biological signaling is common in animals. In humans, androstadienone (ANDR, a synthetic male steroid, is a socially relevant chemosignal exhibited to increase positive mood and cortisol levels specifically in (periovulatory females in positively arousing contexts. In a negative context, we expected that such effects of ANDR could amplify social evaluative threat depending on the stress sensitivity, which differs between menstrual cycle phases. Therefore, this fMRI study aimed to examine psychosocial stress reactions on behavioral, hormonal and neural levels in 31 naturally cycling females, between 15 early follicular (EF and 16 mid-luteal (ML females tested with ANDR and placebo treatment in a repeated-measures design.Regardless of odor stimulation, psychosocial stress (i.e. mental arithmetic task with social evaluative threat led to elevated negative mood and anxiety in all females. A negative association of social threat related amygdala activation and competence ratings appeared in ML-females, indicating enhanced threat processing by ANDR, particularly in ML-females who felt less competent early in the stress experience. Further, ML-females showed reduced performance and stronger stress-related hippocampus activation compared to EF-females under ANDR. Hippocampal activation in ML-females also correlated positively with post-stress subjective stress. Contrarily, such patterns were not observed in EF-females or under placebo in either group. Strikingly, unlike passive emotional processing, ANDR in a stressful context decreased cortisol concentration in all females. This points to a more complex interaction of ovarian/gonadal hormones in social threat processing and stress reactivity.Our findings suggest that ANDR enhanced initial evaluation of self-related social threat in ML-females. Female stress reactions are related to stress sensitivity through enhanced awareness and processing of social cues in a

  9. Detection of myocardial ischemia by automated, motion-corrected, color-encoded perfusion maps compared with visual analysis of adenosine stress cardiovascular magnetic resonance imaging at 3 T: a pilot study.

    Science.gov (United States)

    Doesch, Christina; Papavassiliu, Theano; Michaely, Henrik J; Attenberger, Ulrike I; Glielmi, Christopher; Süselbeck, Tim; Fink, Christian; Borggrefe, Martin; Schoenberg, Stefan O

    2013-09-01

    The purpose of this study was to compare automated, motion-corrected, color-encoded (AMC) perfusion maps with qualitative visual analysis of adenosine stress cardiovascular magnetic resonance imaging for detection of flow-limiting stenoses. Myocardial perfusion measurements applying the standard adenosine stress imaging protocol and a saturation-recovery temporal generalized autocalibrating partially parallel acquisition (t-GRAPPA) turbo fast low angle shot (Turbo FLASH) magnetic resonance imaging sequence were performed in 25 patients using a 3.0-T MAGNETOM Skyra (Siemens Healthcare Sector, Erlangen, Germany). Perfusion studies were analyzed using AMC perfusion maps and qualitative visual analysis. Angiographically detected coronary artery (CA) stenoses greater than 75% or 50% or more with a myocardial perfusion reserve index less than 1.5 were considered as hemodynamically relevant. Diagnostic performance and time requirement for both methods were compared. Interobserver and intraobserver reliability were also assessed. A total of 29 CA stenoses were included in the analysis. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for detection of ischemia on a per-patient basis were comparable using the AMC perfusion maps compared to visual analysis. On a per-CA territory basis, the attribution of an ischemia to the respective vessel was facilitated using the AMC perfusion maps. Interobserver and intraobserver reliability were better for the AMC perfusion maps (concordance correlation coefficient, 0.94 and 0.93, respectively) compared to visual analysis (concordance correlation coefficient, 0.73 and 0.79, respectively). In addition, in comparison to visual analysis, the AMC perfusion maps were able to significantly reduce analysis time from 7.7 (3.1) to 3.2 (1.9) minutes (P < 0.0001). The AMC perfusion maps yielded a diagnostic performance on a per-patient and on a per-CA territory basis comparable with the visual analysis

  10. Measurement of myocardial perfusion using magnetic resonance

    DEFF Research Database (Denmark)

    Fritz-Hansen, T.; Jensen, L.T.; Larsson, H.B.

    2008-01-01

    Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper reviews...... myocardial perfusion imaging with MR contrast agents: methods, validation and experiences from clinical studies. Unresolved issues still restrict the use of these techniques to research although clinical applications are within reach Udgivelsesdato: 2008/12/8...

  11. The Effect of Heart Rate on Exposure Window and Best Phase for Stress Perfusion Computed Tomography: Lessons From the CORE320 Study.

    Science.gov (United States)

    Steveson, Chloe; Schuijf, Joanne D; Vavere, Andrea L; Mather, Richard T; Caton, Teresa; Mehra, Vishal; Betoko, Aisha; Cox, Christopher; Lima, Joao Ac; George, Richard T

    The aim of this study is to evaluate the effect of heart rate on exposure window, best phase, and image quality for stress computed tomography perfusion (CTP) in the CORE320 study. The CTP data sets were analyzed to determine the best phase for perfusion analysis. A predefined exposure window covering 75% to 95% of the R-R cycle was used. Of the 368 patients included in the analysis, 93% received oral β blockade before the rest scan. The median heart rate during the stress acquisition was 69 bpm (interquartile range [IQR], 60-77). The median best phase was 81% (IQR, 76-90), and length of exposure window was 22% (IQR, 19-24). The best phase was significantly later in the cardiac cycle with higher heart rates (P stress scan was 5.3 mSv (IQR, 3.8-6.1). Stress myocardial CTP imaging can be performed using prospective electrocardiography triggering, an exposure window of 75% to 95%, and β-blockade resulting in good or excellent image quality in the majority (80%) of patients while maintaining a low effective radiation dose.

  12. Quantitative perfusion imaging in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zoellner, F.G.; Gaa, T.; Zimmer, F.; Ong, M.M.; Riffel, P.; Hausmann, D.; Schoenberg, S.O.; Weis, M.

    2016-01-01

    Magnetic resonance imaging (MRI) is recognized for its superior tissue contrast while being non-invasive and free of ionizing radiation. Due to the development of new scanner hardware and fast imaging techniques during the last decades, access to tissue and organ functions became possible. One of these functional imaging techniques is perfusion imaging with which tissue perfusion and capillary permeability can be determined from dynamic imaging data. Perfusion imaging by MRI can be performed by two approaches, arterial spin labeling (ASL) and dynamic contrast-enhanced (DCE) MRI. While the first method uses magnetically labelled water protons in arterial blood as an endogenous tracer, the latter involves the injection of a contrast agent, usually gadolinium (Gd), as a tracer for calculating hemodynamic parameters. Studies have demonstrated the potential of perfusion MRI for diagnostics and also for therapy monitoring. The utilization and application of perfusion MRI are still restricted to specialized centers, such as university hospitals. A broad application of the technique has not yet been implemented. The MRI perfusion technique is a valuable tool that might come broadly available after implementation of standards on European and international levels. Such efforts are being promoted by the respective professional bodies. (orig.) [de

  13. Assessment of Reynolds stress components and turbulent pressure loss using 4D flow MRI with extended motion encoding.

    Science.gov (United States)

    Haraldsson, Henrik; Kefayati, Sarah; Ahn, Sinyeob; Dyverfeldt, Petter; Lantz, Jonas; Karlsson, Matts; Laub, Gerhard; Ebbers, Tino; Saloner, David

    2018-04-01

    To measure the Reynolds stress tensor using 4D flow MRI, and to evaluate its contribution to computed pressure maps. A method to assess both velocity and Reynolds stress using 4D flow MRI is presented and evaluated. The Reynolds stress is compared by cross-sectional integrals of the Reynolds stress invariants. Pressure maps are computed using the pressure Poisson equation-both including and neglecting the Reynolds stress. Good agreement is seen for Reynolds stress between computational fluid dynamics, simulated MRI, and MRI experiment. The Reynolds stress can significantly influence the computed pressure loss for simulated (eg, -0.52% vs -15.34% error; P Reynolds stress (P Reynolds stress tensor. The additional information provided by this method improves the assessment of pressure gradients across a stenosis in the presence of turbulence. Unlike conventional methods, which are only valid if the flow is laminar, the proposed method is valid for both laminar and disturbed flow, a common presentation in diseased vessels. Magn Reson Med 79:1962-1971, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  14. Stress-only myocardial perfusion scintigraphy: a prospective study on the accuracy and observer agreement with quantitative coronary angiography as the gold standard.

    Science.gov (United States)

    Ejlersen, June A; May, Ole; Mortensen, Jesper; Nielsen, Gitte L; Lauridsen, Jeppe F; Allan, Johansen

    2017-11-01

    Patients with normal stress perfusion have an excellent prognosis. Prospective studies on the diagnostic accuracy of stress-only scans with contemporary, independent examinations as gold standards are lacking. A total of 109 patients with typical angina and no previous coronary artery disease underwent a 2-day stress (exercise)/rest, gated, and attenuation-corrected (AC), 99m-technetium-sestamibi perfusion study, followed by invasive coronary angiography. The stress datasets were evaluated twice by four physicians with two different training levels (expert and novice): familiar and unfamiliar with AC. The two experts also made a consensus reading of the integrated stress-rest datasets. The consensus reading and quantitative data from the invasive coronary angiography were applied as reference methods. The sensitivity/specificity were 0.92-1.00/0.73-0.90 (reference: expert consensus reading), 0.93-0.96/0.63-0.82 (reference: ≥1 stenosis>70%), and 0.75-0.88/0.70-0.88 (reference: ≥1 stenosis>50%). The four readers showed a high and fairly equal sensitivity independent of their familiarity with AC. The expert familiar with AC had the highest specificity independent of the reference method. The intraobserver and interobserver agreements on the stress-only readings were good (readers without AC experience) to excellent (readers with AC experience). AC stress-only images yielded a high sensitivity independent of the training level and experience with AC of the nuclear physician, whereas the specificity correlated positively with both. Interobserver and intraobserver agreements tended to be the best for physicians with AC experience.

  15. MRI assessment of mid-urethral ligament changes in female stress urinary incontinence

    International Nuclear Information System (INIS)

    Bai Mei; Liu Hongyi; Han Yue; Xu Guoping; Fang Ping; Zhao Yang; Li Jingjin

    2012-01-01

    Objective: To evaluate the MRI value in changes of mid-urethral ligament injury of female stress urinary incontinence (SUI). Methods: Comparison of MRI changes of mid-urethral ligament on 30 healthy female volunteers and 20 female SUI patients. Chi-square test was used to compare the form of SUI patient's mid-urethral support ligaments. Results: The female mid-urethral support ligaments were composed of 4 groups of ligaments, including the periurethral ligament and pubourethral ligaments (1 pair), and at both sides of the urethra's paraurethral ligaments (1 pair) and suburethral ligament lying dorsal urethra, connecting the urethra and pelvic arcus tendinous fasciae. In normal MRI, ligament was a thin strip and showed low signal on both T 1 WI and T 2 WI, T 2 WI sagittal and cross-section scan was the best combination to show the middle urethral support ligaments changes, with tension; 6 patients (20%) in the 30 patients normal control group could be seen tortuously and slack like around the urethra ligaments. Twenty SUI patients mid-urethral support ligaments were performance laxity or rupture,rates were 39% (47/120) and 42% (50/120) (χ 2 =43.191, P<0.05). On T 2 WI, the ligamentous laxity was floating,and loss tension, also could performance one side extension and thinner than the other side. The ligament rupture was performance of the signal interruption, ligament contracture and one end of ligament attachment points separation. Conclusion: MRI can objective effective evaluate the mid-urethral support ligaments' pathological changes in stress urinary incontinence patients. (authors)

  16. Tumor Vessel Compression Hinders Perfusion of Ultrasonographic Contrast Agents

    Directory of Open Access Journals (Sweden)

    Mirco Galiè

    2005-05-01

    Full Text Available Contrast-enhanced ultrasound (CEUS is an advanced approach to in vivo assessment of tumor vascularity and is being increasingly adopted in clinical oncology. It is based on 1- to 10 μm-sized gas microbubbles, which can cross the capillary beds of the lungs and are effective echo enhancers. It is known that high cell density, high transendothelial fluid exchange, and poorly functioning lymphatic circulation all provoke solid stress, which compresses vessels and drastically reduces tumor blood flow. Given their size, we supposed that the perfusion of microbubbles is affected by anatomic features of tumor vessels more than are contrast agents traditionally used in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI. Here, we compared dynamic information obtained from CEUS and DCE-MRI on two experimental tumor models exhibiting notable differences in vessel anatomy. We found that tumors with small, flattened vessels show a much higher resistance to microbubble perfusion than to MRI contrast agents, and appear scarcely vascularized at CEUS examination, despite vessel volume adequate for normal function. Thus, whereas CEUS alone could induce incorrect diagnosis when tumors have small or collapsed vessels, integrated analysis using CEUS and DCE-MRI allows in vivo identification of tumors with a vascular profile frequently associated with malignant phenotypes.

  17. Tumor Vessel Compression Hinders Perfusion of Ultrasonographic Contrast Agents1

    Science.gov (United States)

    Galiè, Mirco; D'Onofrio, Mirko; Montani, Maura; Amici, Augusto; Calderan, Laura; Marzola, Pasquina; Benati, Donatella; Merigo, Flavia; Marchini, Cristina; Sbarbati, Andrea

    2005-01-01

    Abstract Contrast-enhanced ultrasound (CEUS) is an advanced approach to in vivo assessment of tumor vascularity and is being increasingly adopted in clinical oncology. It is based on 1- to 10 µm-sized gas microbubbles, which can cross the capillary beds of the lungs and are effective echo enhancers. It is known that high cell density, high transendothelial fluid exchange, and poorly functioning lymphatic circulation all provoke solid stress, which compresses vessels and drastically reduces tumor blood flow. Given their size, we supposed that the perfusion of microbubbles is affected by anatomic features of tumor vessels more than are contrast agents traditionally used in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Here, we compared dynamic information obtained from CEUS and DCE-MRI on two experimental tumor models exhibiting notable differences in vessel anatomy. We found that tumors with small, flattened vessels show a much higher resistance to microbubble perfusion than to MRI contrast agents, and appear scarcely vascularized at CEUS examination, despite vessel volume adequate for normal function. Thus, whereas CEUS alone could induce incorrect diagnosis when tumors have small or collapsed vessels, integrated analysis using CEUS and DCE-MRI allows in vivo identification of tumors with a vascular profile frequently associated with malignant phenotypes. PMID:15967105

  18. High coronary artery calcium score affects clinical outcome despite normal stress myocardial perfusion imaging and normal left ventricular ejection fraction

    DEFF Research Database (Denmark)

    Madsen, Claus Juul; Andersen, Kim F; Zerahn, Bo

    2013-01-01

    Normal myocardial perfusion imaging (MPI) indicates a low risk for cardiac death and new ischaemic events. However, the impact of normal MPI combined with a high coronary artery calcium score (CACS) is not clear. The aims of this study were to evaluate the risk of severely elevated CACS and to id......Normal myocardial perfusion imaging (MPI) indicates a low risk for cardiac death and new ischaemic events. However, the impact of normal MPI combined with a high coronary artery calcium score (CACS) is not clear. The aims of this study were to evaluate the risk of severely elevated CACS...

  19. Simultaneous Multiagent Hyperpolarized 13C Perfusion Imaging

    DEFF Research Database (Denmark)

    von Morze, Cornelius; Bok, Robert A.; Reed, Galen D.

    2014-01-01

    in simulations. "Tripolarized" perfusion MRI methods were applied to initial preclinical studies with differential conditions of vascular permeability, in normal mouse tissues and advanced transgenic mouse prostate tumors. Results: Dynamic imaging revealed clear differences among the individual tracer...... distributions. Computed permeability maps demonstrated differential permeability of brain tissue among the tracers, and tumor perfusion and permeability were both elevated over values expected for normal tissues. Conclusion: Tripolarized perfusion MRI provides new molecular imaging measures for specifically...

  20. Strain-encoded cardiac MRI as an adjunct for dobutamine stress testing: incremental value to conventional wall motion analysis.

    Science.gov (United States)

    Korosoglou, Grigorios; Lossnitzer, Dirk; Schellberg, Dieter; Lewien, Antje; Wochele, Angela; Schaeufele, Tim; Neizel, Mirja; Steen, Henning; Giannitsis, Evangelos; Katus, Hugo A; Osman, Nael F

    2009-03-01

    High-dose dobutamine stress MRI is safe and feasible for the diagnosis of coronary artery disease (CAD) in humans. However, the assessment of cine scans relies on the visual interpretation of regional wall motion, which is subjective. Recently, strain-encoded MRI (SENC) has been proposed for the direct color-coded visualization of myocardial strain. The purpose of our study was to compare the diagnostic value of SENC with that provided by conventional wall motion analysis for the detection of inducible ischemia during dobutamine stress MRI. Stress-induced ischemia was assessed by wall motion analysis and by SENC in 101 patients with suspected or known CAD and in 17 healthy volunteers who underwent dobutamine stress MRI in a clinical 1.5-T scanner. Quantitative coronary angiography deemed as the standard reference for the presence or absence of significant CAD (> or =50% diameter stenosis). On a coronary vessel level, SENC detected inducible ischemia in 86 of 101 versus 71 of 101 diseased coronary vessels (P or =50% stenosis (area under the curve, 0.96; SE, 0.01; 95% CI, 0.94 to 0.98; P<0.001). The direct color-coded visualization of strain on MR images is a useful adjunct for dobutamine stress MRI, which provides incremental value for the detection of CAD compared with conventional wall motion readings on cine images.

  1. The prognostic value of 99MTc-MIBI stress-rest myocardial perfusion imaging in patients suspected with coronary artery disease

    International Nuclear Information System (INIS)

    Wu Zhifang; Li Sijin; Liu Jianzhong; Zhang Wanchun

    2004-01-01

    Objective: To evaluate the prognostic value of 99mTc-MIBI stress-rest myocardial perfusion imaging (MPI) for patients suspected with coronary artery disease (CAD). Methods: 206 consecutive patients suspected with CAD (165 males, 41 females; age range 16-90 years, mean age 55.94±12.46 years) underwent 99mTc-MIBI stress-rest myocardial perfusion imaging (two days protocol), 57 pts with hypertension, 68 pts with hyperlipemia, 39 pts with diabetes and 62 pts with the family history of CAD. According to the imaging results, the 206 patients were divided into 3 groups. G1, normal, 135 pts; G2, reversible defects, 20 pts; G3, fixed defects, 51 pts. The mean time of follow-up was 33.25±14.95 (1-56) months. Results: The rate of cardiac events (CE) occurrence of the three groups was 1.5% (2/135), 65% ( 13/20) and 7.8% (4/51) respectively and there was significant difference between them. Kaplan-Meier survival curves analyzing the no-CE rates in the three groups, ischemic patients demonstrated a more significantly lower than normal and infarction ones in the no-CE rates(Log-rank statistic, chi-square 124.89, P <0.0001). The better predictor of future cardiac events is the reversible defect. Over all, 23.9% of the patients with abnormal stress MPI occurred cardiac events, but only 7.5% of the patients with abnormal rest ones did(chi-square 5.80, P =0.016). The prognoses of patients with normal stress MPI result were better than those with normal rest ones (1.5% versus 9.7%, chi-square 8.94, P =0.0028). Compared with rest MPI, the stress one is a better predictable method to analyze the patient' s condition and evaluate the prognosis. Conclusions: 99mTc-MIBI stress-rest myocardial perfusion imaging is a better Methods to evaluate the prognosis of patients suspected with CAD, and the rate of CE occurrence was 65% in reversible defects patients in this study. (authors)

  2. Renal perfusion scintiscan

    Science.gov (United States)

    ... Radionuclide renal perfusion scan; Perfusion scintiscan - renal; Scintiscan - renal perfusion Images Kidney anatomy Kidney - blood and urine flow Intravenous pyelogram References Rottenberg G, Andi AC. Renal ...

  3. 3T MRI induced post-traumatic stress disorder: a case report

    Directory of Open Access Journals (Sweden)

    Lakhan Shaheen E

    2012-10-01

    Full Text Available Abstract Introduction MRI is considered a safe and well tolerated imaging technique with risks largely limited to heating and/or displacement of implanted ferromagnetic metal in the patient’s body, worsening anxiety, triggering claustrophobia, and gadolinium induced nephrogenic systemic fibrosis. Case presentation We present a case of a 26 year old Asian American man with no significant past medical or psychiatric history and two months of left T4 radicular pain. During 3T-MRI of the whole spine, the patient experienced acute agitation, fear, anxiety, tachypnea, tachycardia with palpitations, and dizziness. He felt intense surface heat over segments of his body and very loud noises. He perceived impending serious bodily harm by the scanner. The scan was aborted at the lumbar spine, and cervical and thoracic spine was unremarkable. The patient’s pain resolved in the weeks following with over the counter analgesics, however, he developed increased arousal, re-experiencing the event, persistent avoidance, and significant psychosocial impairment consistent with DSM-IV-TR criteria for post-traumatic stress disorder (PTSD. Conclusion This is the first reported case of MRI induced PTSD. Theoretically, the high-magnetic field of the 3T scanner may have contributed to the development of symptoms.

  4. Clinical value of atropine-four minutes adenosine stressed 99Tcm-MIBI myocardial perfusion imaging in the diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Peng Xulan; Zhang Baoniu; Jiang Sufang; Liang Hongwei; Liu Jun; Gao Guizhu; Ding Minghui; Hou Junfu

    2008-01-01

    Objective: The aim of this study was to compare the diagnostic efficacy of atropine-4 min adenosine stressed 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging in the diagnosis of coronary artery disease (CAD). Methods: A total of 56 patients were divided into atropine-4 min adenosine stress (research group) and 6 min adenosine infusion (control group). The sex, age, the severity of CAD (judged by coronary, angiography) and associated symptoms were matched between the 2 groups. In research group, 0.5 mg atropine was injected intravenously 10 min before adenosine infusion. Adenosine was infused at a rate of 0.14 mg·kg -1 ·min -1 intravenously for 4 min and 6 min in research and control groups. At 3 min after adenosine infusion, 740 MBq 99 Tc m -MIBI was injected. SPECT myocardial imaging was obtained 1.5 h later. A rest myocardial perfusion imaging was performed on the following day. Results: (1) In research group and control group, the sensitivity, specificity, diagnostic accuracy was 85%, 6/8, 82% and 86%, 5/7, 82%, respectively (χ 2 0.05). (2)The sensitivity of the adenosine test for detection of single vessel, two vessels, three vessels disease were 6/7, 8/9, 3/4 and 7/8, 7/8, 4/5 in research group and control group, respectively(χ 2 0.05). (3) Side affects occurred in 82% of the patients in the research group and in 89% of the patients in the control group. The incidence of side effects in the two groups was not significantly different besides chest depression (43% and 68%, χ 2 =4.000, <0.05). Conclusions: Atropine-4 min adenosine infusion, in combination with perfusion tomography, has similar diagnostic efficacy for CAD to the 6 min protocol, and has lower incidence of chest depression than the standard 6 min infusion. (authors)

  5. Interleaved MRI/MRS study of muscle perfusion, oxygenation and high energy phosphate metabolism in normal subjects and Becker's myopathic patients

    International Nuclear Information System (INIS)

    Toussaint, J.F.; Brillault-Salvat, C.; Giacomini, E.; Bloch, G.; Duboc, D.; Jehenson, P.

    1998-01-01

    We present the first results of a study comparing patients suffering from Becker's myopathy and normal volunteers. We simultaneously assessed perfusion, oxygenation and high-energy phosphate metabolism using an interleaved NMR/NMRS approach. Muscle metabolism does not seem to differ in Becker's patients, except for myoglobin reoxygenation rates. (authors)

  6. Measurement of brain perfusion, blood volume, and blood-brain barrier permeability, using dynamic contrast-enhanced T(1)-weighted MRI at 3 tesla

    DEFF Research Database (Denmark)

    Larsson, Henrik B W; Courivaud, Frédéric; Rostrup, Egill

    2009-01-01

    Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... on a pixel-by-pixel basis of cerebral perfusion, cerebral blood volume, and blood-brain barrier permeability.......Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... imaging of a bolus of a paramagnetic contrast agent passing through the brain. The methods are applied in patients with brain tumors and in healthy subjects. Perfusion was estimated by model-free deconvolution using Tikhonov's method (gray matter/white matter/tumor: 72 +/- 16/30 +/- 8/56 +/- 45 mL/100 g...

  7. Diagnostic accuracy of unenhanced, contrast-enhanced perfusion and angiographic MRI sequences for pulmonary embolism diagnosis: results of independent sequence readings

    Energy Technology Data Exchange (ETDEWEB)

    Revel, Marie Pierre [Hopital Europeen Georges Pompidou, APHP, Departments of Radiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); Hotel-Dieu, Service de Radiologie, Paris (France); Sanchez, Olivier; Meyer, Guy [Hopital Europeen Georges Pompidou, APHP, Respiratory and intensive care and, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); INSERM Unite 765, Paris (France); Lefort, Catherine; Couchon, Sophie; Hernigou, Anne; Frija, Guy [Hopital Europeen Georges Pompidou, APHP, Departments of Radiology, Paris (France); Niarra, Ralph [Hopital Europeen Georges Pompidou, APHP, Clinical Epidemiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); Chatellier, Gilles [Hopital Europeen Georges Pompidou, APHP, Clinical Epidemiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); INSERM CIC-EC E4, Paris (France)

    2013-09-15

    To independently evaluate unenhanced, contrast-enhanced perfusion and angiographic MR sequences for pulmonary embolism (PE) diagnosis. Prospective investigation, including 274 patients who underwent perfusion, unenhanced 2D steady-state-free-precession (SSFP) and contrast-enhanced 3D angiographic MR sequences on a 1.5-T unit, in addition to CTA (CT angiography). Two independent readers evaluated each sequence independently in random order. Sensitivity, specificity, predictive values and inter-reader agreement were calculated for each sequence, excluding sequences judged inconclusive. Sensitivity was also calculated according to PE location. Contrast-enhanced angiographic sequences showed the highest sensitivity (82.9 and 89.7 %, reader 1 and reader 2, respectively), specificity (98.5 and 100 %) and agreement (kappa value 0.77). Unenhanced angiographic sequences, although less sensitive overall (68.7 and 76.4 %), were sensitive for the detection of proximal PE (92.7 and 100 %) and showed high specificity (96.1 and 99.1 %) and good agreement (kappa value 0.62). Perfusion sequences showed lower sensitivity (75.0 and 79.3 %), specificity (84.8 and 89.7 %) and agreement (kappa value 0.51), and a negative predictive value of 84.8 % at best. Compared with contrast-enhanced angiographic sequences, unenhanced sequences demonstrate lower sensitivity, except for proximal PE, but high specificity and agreement. The negative predictive value of perfusion sequences was insufficient to safely rule out PE. (orig.)

  8. Brain capillary transit time heterogeneity in healthy volunteers measured by dynamic contrast-enhanced T1-weighted perfusion MRI

    DEFF Research Database (Denmark)

    Larsson, Henrik B.W.; Vestergaard, Mark B.; Lindberg, Ulrich

    2017-01-01

    Purpose: Capillary transit time heterogeneity, measured as CTH, may set the upper limit for extraction of substances in brain tissue, e.g., oxygen. The purpose of this study was to investigate the feasibility of dynamic contrast-enhanced T1 weighted MRI (DCE-MRI) at 3 Tesla (T), in estimating CTH...

  9. Perfusion Quantification Using Gaussian Process Deconvolution

    DEFF Research Database (Denmark)

    Andersen, Irene Klærke; Have, Anna Szynkowiak; Rasmussen, Carl Edward

    2002-01-01

    The quantification of perfusion using dynamic susceptibility contrast MRI (DSC-MRI) requires deconvolution to obtain the residual impulse response function (IRF). In this work, a method using the Gaussian process for deconvolution (GPD) is proposed. The fact that the IRF is smooth is incorporated...

  10. Posterior midline activation during symptom provocation in acute stress disorder: An fMRI study

    Directory of Open Access Journals (Sweden)

    Jan Christopher Cwik

    2014-05-01

    Full Text Available Functional imaging studies of patients with Posttraumatic Stress Disorder showed wide-spread activation of mid-line cortical areas during symptom provocation i.e., exposure to trauma-related cues. The present study aimed at investigating neural activation during exposure to trauma-related pictures in patients with Acute Stress Disorder (ASD shortly after the traumatic event. Nineteen ASD patients and 19 healthy control participants were presented with individualized pictures of the traumatic event and emotionally neutral control pictures during the acquisition of whole-brain data with a 3-T fMRI scanner. Compared to the control group and to control pictures, ASD patients showed significant activation in mid-line cortical areas in response to trauma-related pictures including precuneus, cuneus, postcentral gyrus and pre-supplementary motor area. The results suggest that the trauma-related pictures evoke emotionally salient self-referential processing in ASD patients.

  11. Resting electrocardiogram and stress myocardial perfusion imaging in the determination of left ventricular systolic function: an assessment enhancing the performance of gated SPET.

    Science.gov (United States)

    Moralidis, Efstratios; Spyridonidis, Tryfon; Arsos, Georgios; Skeberis, Vassilios; Anagnostopoulos, Constantinos; Gavrielidis, Stavros

    2010-01-01

    This study aimed to determine systolic dysfunction and estimate resting left ventricular ejection fraction (LVEF) from information collected during routine evaluation of patients with suspected or known coronary heart disease. This approach was then compared to gated single photon emission tomography (SPET). Patients having undergone stress (201)Tl myocardial perfusion imaging followed by equilibrium radionuclide angiography (ERNA) were separated into derivation (n=954) and validation (n=309) groups. Logistic regression analysis was used to develop scoring systems, containing clinical, electrocardiographic (ECG) and scintigraphic data, for the discrimination of an ERNA-LVEFstatistic (mean+/-2SD) provided values of 0.001+/-0.176, 0.071+/-0.196 and 0.040+/-0.152, respectively. The average LVEF was a better discriminator of systolic dysfunction than gated SPET-LVEF in receiver operating characteristic (ROC) analysis and identified more patients (89%) with a stress myocardial perfusion imaging variables. This model provides reliable LVEF estimations, comparable to those from (201)Tl gated SPET, and can enhance the clinical performance of the latter.

  12. Bone stress injury of the ankle in professional ballet dancers seen on MRI

    Directory of Open Access Journals (Sweden)

    Besser Marcus P

    2008-03-01

    Full Text Available Abstract Background Ballet Dancers have been shown to have a relatively high incidence of stress fractures of the foot and ankle. It was our objective to examine MR imaging patterns of bone marrow edema (BME in the ankles of high performance professional ballet dancers, to evaluate clinical relevance. Methods MR Imaging was performed on 12 ankles of 11 active professional ballet dancers (6 female, 5 male; mean age 24 years, range 19 to 32. Individuals were imaged on a 0.2 T or 1.5 T MRI units. Images were evaluated by two musculoskeletal radiologists and one orthopaedic surgeon in consensus for location and pattern of bone marrow edema. In order to control for recognized sources of bone marrow edema, images were also reviewed for presence of osseous, ligamentous, tendinous and cartilage injuries. Statistical analysis was performed to assess the strength of the correlation between bone marrow edema and ankle pain. Results Bone marrow edema was seen only in the talus, and was a common finding, observed in nine of the twelve ankles imaged (75% and was associated with pain in all cases. On fluid-sensitive sequences, bone marrow edema was ill-defined and centered in the talar neck or body, although in three cases it extended to the talar dome. No apparent gender predilection was noted. No occult stress fracture could be diagnosed. A moderately strong correlation (phi = 0.77, p= 0.0054 was found between edema and pain in the study population. Conclusion Bone marrow edema seems to be a specific MRI finding in the talus of professional ballet dancers, likely related to biomechanical stress reactions, due to their frequently performed unique maneuvers. Clinically, this condition may indicate a sign of a bone stress injury of the ankle.

  13. Bone stress injury of the ankle in professional ballet dancers seen on MRI

    Science.gov (United States)

    Elias, Ilan; Zoga, Adam C; Raikin, Steven M; Peterson, Judith R; Besser, Marcus P; Morrison, William B; Schweitzer, Mark E

    2008-01-01

    Background Ballet Dancers have been shown to have a relatively high incidence of stress fractures of the foot and ankle. It was our objective to examine MR imaging patterns of bone marrow edema (BME) in the ankles of high performance professional ballet dancers, to evaluate clinical relevance. Methods MR Imaging was performed on 12 ankles of 11 active professional ballet dancers (6 female, 5 male; mean age 24 years, range 19 to 32). Individuals were imaged on a 0.2 T or 1.5 T MRI units. Images were evaluated by two musculoskeletal radiologists and one orthopaedic surgeon in consensus for location and pattern of bone marrow edema. In order to control for recognized sources of bone marrow edema, images were also reviewed for presence of osseous, ligamentous, tendinous and cartilage injuries. Statistical analysis was performed to assess the strength of the correlation between bone marrow edema and ankle pain. Results Bone marrow edema was seen only in the talus, and was a common finding, observed in nine of the twelve ankles imaged (75%) and was associated with pain in all cases. On fluid-sensitive sequences, bone marrow edema was ill-defined and centered in the talar neck or body, although in three cases it extended to the talar dome. No apparent gender predilection was noted. No occult stress fracture could be diagnosed. A moderately strong correlation (phi = 0.77, p= 0.0054) was found between edema and pain in the study population. Conclusion Bone marrow edema seems to be a specific MRI finding in the talus of professional ballet dancers, likely related to biomechanical stress reactions, due to their frequently performed unique maneuvers. Clinically, this condition may indicate a sign of a bone stress injury of the ankle. PMID:18371230

  14. Effect of caffeine on SPECT myocardial perfusion imaging during regadenoson pharmacologic stress: rationale and design of a prospective, randomized, multicenter study.

    Science.gov (United States)

    Tejani, Furqan H; Thompson, Randall C; Iskandrian, Ami E; McNutt, Bruce E; Franks, Billy

    2011-02-01

    Caffeine attenuates the coronary hyperemic response to adenosine by competitive A₂(A) receptor blockade. This study aims to determine whether oral caffeine administration compromises diagnostic accuracy in patients undergoing vasodilator stress myocardial perfusion imaging (MPI) with regadenoson, a selective adenosine A(2A) agonist. This multicenter, randomized, double-blind, placebo-controlled, parallel-group study includes patients with suspected coronary artery disease who regularly consume caffeine. Each participant undergoes three SPECT MPI studies: a rest study on day 1 (MPI-1); a regadenoson stress study on day 3 (MPI-2), and a regadenoson stress study on day 5 with double-blind administration of oral caffeine 200 or 400 mg or placebo capsules (MPI-3; n = 90 per arm). Only participants with ≥ 1 reversible defect on the second MPI study undergo the subsequent stress MPI test. The primary endpoint is the difference in the number of reversible defects on the two stress tests using a 17-segment model. Pharmacokinetic/pharmacodynamic analyses will evaluate the effect of caffeine on the regadenoson exposure-response relationship. Safety will also be assessed. The results of this study will show whether the consumption of caffeine equivalent to 2-4 cups of coffee prior to an MPI study with regadenoson affects the diagnostic validity of stress testing (ClinicalTrials.gov number, NCT00826280).

  15. Perfusion CT in acute stroke

    International Nuclear Information System (INIS)

    Eckert, Bernd; Roether, Joachim; Fiehler, Jens; Thomalla, Goetz

    2015-01-01

    Modern multislice CT scanners enable multimodal protocols including non-enhanced CT, CT angiography, and CT perfusion. A 64-slice CT scanner provides 4-cm coverage. To cover the whole brain, a 128 - 256-slice scanner is needed. The use of perfusion CT requires an optimized scan protocol in order to reduce exposure to radiation. As compared to non-enhanced CT and CT angiography, the use of CT perfusion increases detection rates of cerebral ischemia, especially small cortical ischemic lesions, while the detection of lacunar and infratentorial stroke lesions remains limited. Perfusion CT enables estimation of collateral flow in acute occlusion of large intra- or extracranial arteries. Currently, no established reliable thresholds are available for determining infarct core and penumbral tissue by CT perfusion. Moreover, perfusion parameters depend on the processing algorithms and the software used for calculation. However, a number of studies point towards a reduction of cerebral blood volume (CBV) below 2 ml/100 g as a critical threshold that identifies infarct core. Large CBV lesions are associated with poor outcome even in the context of recanalization. The extent of early ischemic signs on non-enhanced CT remains the main parameter from CT imaging to guide acute reperfusion treatment. Nevertheless, perfusion CT increases diagnostic and therapeutic certainty in the acute setting. Similar to stroke MRI, perfusion CT enables the identification of tissue at risk of infarction by the mismatch between infarct core and the larger area of critical hypoperfusion. Further insights into the validity of perfusion parameters are expected from ongoing trials of mechanical thrombectomy in stroke.

  16. Measurement of perfusion using the first-pass dynamic susceptibility-weighted contrast-enhanced (DSC) MRI in neurooncology. Physical basics and clinical applications; Perfusionsmessung mit der T2*-Kontrastmitteldynamik in der Neuroonkologie. Physikalische Grundlagen und klinische Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Weber, M.-A.; Giesel, F.L.; Kauczor, H.-U.; Essig, M. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg (Germany). Abteilung Radiologie; Risse, F.; Schad, L.R. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg (Germany). Abteilung Medizinische Physik in der Radiologie

    2005-07-01

    Perfusion imaging in the central nervous system (CNS) is mostly performed using the first-pass dynamic susceptibility-weighted contrast-enhanced (DSC) MRI. The first-pass of a contrast bolus in brain tissue is monitored by a series of T2*-weighted MR images. The susceptibility effect of the paramagnetic contrast agent leads to a signal loss that can be converted, using the principles of the indicator dilution theory, into an increase of the contrast agent concentration. From these data, parameter maps of cerebral blood volume (CBV) and flow (CBF) can be derived. Regional CBF and CBV values can be obtained by region-of-interest analysis. This review article describes physical basics of DSC MRI and summarizes the literature of DSC MRI in neurooncological issues. Studies, all with relatively limited patient numbers, report that DSC MRI is useful in the preoperative diagnosis of gliomas, CNS-lymphomas, and solitary metastases, as well as in the differentiation of these neoplastic lesions from infections and tumor-like manifestations of demyelinating disease. Additionally, DSC MRI is suitable for determining glioma grade and regions of active tumor growth which should be the target of stereotactic biopsy. After therapy, DSC MRI helps better assessing the tumor response to therapy, residual tumor after therapy, and possible treatment failure and therapy-related complications, such as radiation necrosis. The preliminary results show that DSC MRI is a diagnostic tool depicting regional variations in microvasculature of normal and diseased brains. (orig.) [German] Die MRT-Perfusionsmessungen im Zentralnervensystem (ZNS) werden derzeit hauptsaechlich mit der kontrastmittelverstaerkten T2*-Dynamik durchgefuehrt, die die Passage eines schnellen Kontrastmittelbolus mit einer Serie von T2*-gewichteten MRT-Aufnahmen verfolgt und charakterisiert. Dabei wird der Signalabfall, bedingt durch den Suszeptibilitaetseffekt des paramagnetischen Kontrastmittels, mittels geeigneter

  17. A stress MRI of the shoulder for evaluation of ligamentous stabilizers in acute and chronic acromioclavicular joint instabilities.

    Science.gov (United States)

    Izadpanah, Kaywan; Winterer, Jan; Vicari, Marco; Jaeger, Martin; Maier, Dirk; Eisebraun, Leonie; Ute Will, Jutta; Kotter, Elmar; Langer, Mathias; Südkamp, Norbert P; Hennig, Jürgen; Weigel, Mathias

    2013-06-01

    To show the feasibility of a stress magnetic resonance imaging (MRI) as a new method for simultaneous evaluation of the morphology and the functional integrity of the acromioclavicular joint (ACJ) ligamentous stabilizers. MRI of four volunteers, 10 patients with acute, and six with chronic ACJ injuries was performed using a 0.25 T open MRI scanner. A 2D-proton-density and a 3D-gradient-echo sequence at rest and under 6.5 kg shoulder traction were performed. Comparative measurements of the coracoclavicular and the acromioclavicular distance were performed. Additionally, the conoid and trapezoid ligament lengths were measured with multiplanar reconstructions. MRI at rest correctly identified tears of the coracoclavicular and the acromioclavicular ligaments in eight patients suffering acute ACJ injuries. Stress application helped to distinguish between partial and complete coracoclavicular ligament tears in two cases. Insufficiency of the ACJ ligaments was present in all acute and chronic ACJ injuries. Stress application in chronic ACJ ligaments revealed isolated insufficiency of the conoid ligament in three cases and of the trapezoid ligament in one case. Combined insufficiency was present in two cases. Stress MRI facilitates simultaneous acquisition of morphologic and functional information of the ACJ stabilizers. In acute ACJ injuries it helps to distinguish between partial and complete ligament tears. In chronic ACJ injuries it provides functional information of the ligament regrinds. Copyright © 2012 Wiley Periodicals, Inc.

  18. The impact of adenosine pharmacologic stress combined with low-level exercise in patients undergoing myocardial perfusion imaging (BIWAKO adenosine-Ex trial)

    International Nuclear Information System (INIS)

    Monzen, Hajime; Hara, Masatake; Hirata, Makoto

    2011-01-01

    The combination of adenosine infusion with low-level exercise has become a common approach for inducing stress during stress myocardial perfusion imaging (MPI). We investigated stress MPI performed by combined low-level exercise and adenosine infusion. This combined protocol can decrease adverse reactions and reduce the effect of scattered rays from the liver. Subjects were clinically referred for a 53-min rest-stress Tc-99m Sestamibi MPI procedure using BIWAKO PROTOCOL. Ninety-eight patients (44.5%) underwent adenosine infusion with ergometer exercise testing and 122 patients (55.5%) underwent adenosine infusion without exercise testing. We evaluated the liver/heart (L/H) uptake ratio, background activity in the upper mediastinum, and adverse reactions. The L/H ratio and background activity were lower in the adenosine-exercise group than in the adenosine-non-exercise group (1.8±0.54 vs. 2.1±0.62, P<0.0056; 43.1±12.2 vs. 61.5±15.4, P<0.0001). The adenosine-exercise group had fewer adverse reactions than the adenosine-non-exercise group (11.2 vs. 19.7%). All of the adverse reactions were minor, with the exception of severe back pain in one case. The incidence of adverse reactions in our study was lower than that in previous studies for unknown reason. Adenosine infusion in combination with low-level exercise seems to result in higher-quality images and fewer adverse reactions than adenosine infusion without exercise. The combined protocol decreases adverse reactions and improves the quality of myocardial perfusion images by decreasing background activity. (author)

  19. Prognostic significance of stress myocardial ECG-gated perfusion imaging in asymptomatic patients with diabetic chronic kidney disease on initiation of haemodialysis

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Mitsuru; Kondo, Chisato; Kobayashi, Hideki; Kusakabe, Kiyoko [Tokyo Women' s Medical University, School of Medicine, Department of Radiology, Shinjuku-ku, Tokyo (Japan); Babazono, Tetsuya [Tokyo Women' s Medical University, School of Medicine, Diabetes Centre, Shinjuku-ku, Tokyo (Japan); Nakajima, Takatomo [Tokyo Women' s Medical University, School of Medicine, Department of Cardiology, Shinjuku-ku, Tokyo (Japan)

    2009-08-15

    Diabetic patients with chronic kidney disease (CKD) frequently develop cardiac events within several years of the initiation of haemodialysis. The present study assesses the prognostic significance of stress myocardial ECG-gated perfusion imaging (MPI) in patients with diabetic CKD requiring haemodialysis. Fifty-five asymptomatic patients with diabetic stage V CKD and no history of heart disease scheduled to start haemodialysis were enrolled in this study (56{+-}11 years old; 49 with type 2 diabetes mellitus). All patients underwent {sup 201}Tl stress ECG-gated MPI 1 month before or after the initiation of haemodialysis to assess myocardial involvement. We evaluated SPECT images using 17-segment defect scores graded on a 5-point scale, summed stress score (SSS) and summed difference scores (SDS). The patients were followed up for at least 2 years (42{+-}15 months) to determine coronary intervention (CI) and heart failure (HF) as soft events and acute myocardial infarction (AMI) and all causes of deaths as hard events. The frequencies of myocardial ischaemia, resting perfusion defects, low ejection fraction and left ventricular (LV) dilatation were 24,20,29 and 49%, respectively. Ten events (18%) developed during the follow-up period including four CI, one HF, one AMI and four sudden deaths. Multivariate Cox analysis selected SDS (p=0.0011) and haemoglobin A{sub 1c} (HbA{sub 1c}) (p=0.0076) as independent prognostic indicators for all events. Myocardial ischaemia, in addition to glycaemic control, is a strong prognostic marker for asymptomatic patients with diabetic CKD who are scheduled to start haemodialysis. Stress MPI is highly recommended for the management and therapeutic stratification of such patients. (orig.)

  20. Functional MRI procedures in the diagnosis of brain tumors. Perfusion- and diffusion-weighted imaging; Funktionelle MR-Verfahren in der Diagnostik intraaxialer Hirntumoren. Perfusions- und Diffusions-Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, M. [Universitaetsklinikum Heidelberg (Germany). Neurologische Klinik, Abteilung Neuroradiologie; Heiland, S.; Sartor, K.

    2002-08-01

    Despite the increased diagnostic accuracy of contrast material enhanced MR imaging, specification and grading of brain tumors are still only approximate at best: neither morphology, nor relaxation times or contrast material enhancement reliably predict tumor histology or tumor grade. As histology and tumor grade strongly influence which therapy concept is chosen, a more precise diagnosis is mandatory. With diffusion- and perfusion-weighted MR imaging (DWI, PWI) it is now possible to obtain important information regarding the cellular matrix and the relative regional cerebral blood volume (rrCBV) of brain tumors, which cannot be obtained with standard MR techniques. These dynamic-functional imaging techniques are very useful in the preoperative diagnosis of gliomas, lymphomas, and metastases, as well as in the differentiation of these neoplastic lesions from abscesses, atypical ischemic infarctions, and tumor-like manifestations of demyelinating disease. Additionally, they appear suitable for determining glioma grade and regions of active tumor growth which should be the target of stereotactic biopsy and therapy. After therapy these techniques are helpful to better assess the tumor response to therapy, possible therapy failure and therapy complications such as radiation necrosis. (orig.) [German] Die radiologische Diagnostik intraaxialer Hirntumoren ist durch die Magnetresonanztomographie (MRT) erheblich verbessert worden, besonders nach Einfuehrung der paramagnetischen Kontrastmittel. Mit konventionellen MR-Verfahren ist aber noch keine verlaessliche Unterscheidung zwischen Gliomen, Metastasen, primaeren Lymphomen und tumorsimulierenden entzuendlichen Erkrankungen moeglich. In dieser Hinsicht vielversprechend sind neue, funktionell-dynamische MR-Verfahren, mit denen sich nicht-invasiv die zerebrale Wasserdiffusion und Mikrozirkulation erfassen lassen und die eine bessere Gewebecharakterisierung erlauben als die herkoemmlichen MR-Methoden. Die Perfusions-MRT erfasst

  1. Is there any correlation between model-based perfusion parameters and model-free parameters of time-signal intensity curve on dynamic contrast enhanced MRI in breast cancer patients?

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Boram; Kang, Doo Kyoung; Kim, Tae Hee [Ajou University School of Medicine, Department of Radiology, Suwon, Gyeonggi-do (Korea, Republic of); Yoon, Dukyong [Ajou University School of Medicine, Department of Biomedical Informatics, Suwon (Korea, Republic of); Jung, Yong Sik; Kim, Ku Sang [Ajou University School of Medicine, Department of Surgery, Suwon (Korea, Republic of); Yim, Hyunee [Ajou University School of Medicine, Department of Pathology, Suwon (Korea, Republic of)

    2014-05-15

    To find out any correlation between dynamic contrast-enhanced (DCE) model-based parameters and model-free parameters, and evaluate correlations between perfusion parameters with histologic prognostic factors. Model-based parameters (Ktrans, Kep and Ve) of 102 invasive ductal carcinomas were obtained using DCE-MRI and post-processing software. Correlations between model-based and model-free parameters and between perfusion parameters and histologic prognostic factors were analysed. Mean Kep was significantly higher in cancers showing initial rapid enhancement (P = 0.002) and a delayed washout pattern (P = 0.001). Ve was significantly lower in cancers showing a delayed washout pattern (P = 0.015). Kep significantly correlated with time to peak enhancement (TTP) (ρ = -0.33, P < 0.001) and washout slope (ρ = 0.39, P = 0.002). Ve was significantly correlated with TTP (ρ = 0.33, P = 0.002). Mean Kep was higher in tumours with high nuclear grade (P = 0.017). Mean Ve was lower in tumours with high histologic grade (P = 0.005) and in tumours with negative oestrogen receptor status (P = 0.047). TTP was shorter in tumours with negative oestrogen receptor status (P = 0.037). We could acquire general information about the tumour vascular physiology, interstitial space volume and pathologic prognostic factors by analyzing time-signal intensity curve without a complicated acquisition process for the model-based parameters. (orig.)

  2. Sex differences, hormones, and fMRI stress response circuitry deficits in psychoses.

    Science.gov (United States)

    Goldstein, Jill M; Lancaster, Katie; Longenecker, Julia M; Abbs, Brandon; Holsen, Laura M; Cherkerzian, Sara; Whitfield-Gabrieli, Susan; Makris, Nicolas; Tsuang, Ming T; Buka, Stephen L; Seidman, Larry J; Klibanski, Anne

    2015-06-30

    Response to stress is dysregulated in psychosis (PSY). fMRI studies showed hyperactivity in hypothalamus (HYPO), hippocampus (HIPP), amygdala (AMYG), anterior cingulate (ACC), orbital and medial prefrontal (OFC; mPFC) cortices, with some studies reporting sex differences. We predicted abnormal steroid hormone levels in PSY would be associated with sex differences in hyperactivity in HYPO, AMYG, and HIPP, and hypoactivity in PFC and ACC, with more severe deficits in men. We studied 32 PSY cases (50.0% women) and 39 controls (43.6% women) using a novel visual stress challenge while collecting blood. PSY males showed BOLD hyperactivity across all hypothesized regions, including HYPO and ACC by FWE-correction. Females showed hyperactivity in HIPP and AMYG and hypoactivity in OFC and mPFC, the latter FWE-corrected. Interaction of group by sex was significant in mPFC (F = 7.00, p = 0.01), with PSY females exhibiting the lowest activity. Male hyperactivity in HYPO and ACC was significantly associated with hypercortisolemia post-stress challenge, and mPFC with low androgens. Steroid hormones and neural activity were dissociated in PSY women. Findings suggest disruptions in neural circuitry-hormone associations in response to stress are sex-dependent in psychosis, particularly in prefrontal cortex. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Combination of MRI hippocampal volumetry and arterial spin labeling MR perfusion at 3-Tesla improves the efficacy in discriminating Alzheimer's disease from cognitively normal elderly adults.

    Science.gov (United States)

    Mak, Henry Ka-Fung; Qian, Wenshu; Ng, Kwok Sing; Chan, Queenie; Song, You-Qiang; Chu, Leung Wing; Yau, Kelvin Kai-Wing

    2014-01-01

    Structural magnetic resonance imaging has been employed for evaluation of medial temporal atrophy in patients with Alzheimer's disease (AD). Arterial spin labeling (ASL) technique could detect cerebral perfusion abnormalities in AD. We hypothesized that combination of hippocampal volumetry and cerebral blood flow yield higher accuracy than either method alone in discriminating AD patients from cognitively normal elderly adults. 13 AD patients and 15 healthy controls were studied using a 3-tesla scanner. Standardized T1W 3D volumetric Fast Field Echo and QUASAR ASL sequences were employed for cerebral volumetry and perfusion respectively. Manual Right and left hippocampal volumetry was performed manually by ANALYZE software, with total intracranial volume normalization. ASL data were analyzed by institutional specially-design software to calculate cerebral blood flow of region-of-interests placed at the middle and posterior cingulate gyri. Right and left hippocampal volumes and middle and posterior cingulate gyri cerebral blood flows were significantly lower in the patients than in the controls (independent-samples t-tests, p volumetry and cerebral perfusion has improved efficacy in discriminating AD patients from cognitively normal elderly adults.

  4. Interpretative intra- and interobserver reproducibility of Stress/Rest 99m Tc-steamboat's myocardial perfusion SPECT using semi quantitative 20-segment model

    International Nuclear Information System (INIS)

    Fazeli, M.; Firoozi, F.

    2002-01-01

    It well established that myocardial perfusion SPECT with 201 T L or 99 mTc-se sta mi bi play an important role diagnosis and risk assessment in patients with known or suspected coronary artery disease. Both quantitative and qualitative methods are available for interpretation of images. The use of a semi quantitative scoring system in which each of 20 segments is scored according to a five-point scheme provides an approach to interpretation that is more systematic and reproducible than simple qualitative evaluation. Only a limited number of studies have dealt with the interpretive observer reproducibility of 99 mTc-steamboat's myocardial perfusion imaging. The aim of this study was to assess the intra-and inter observer variability of semi quantitative SPECT performed with this technique. Among 789 patients that underwent myocardial perfusion SPECT during last year 80 patients finally need to coronary angiography as gold standard. In this group of patients a semi quantitative visual interpretation was carried out using short axis and vertical long-axis myocardial tomograms and a 20-segments model. These segments we reassigned on six evenly spaced regions in the apical, mid-ventricular, and basal short-axis view and two apical segments on the mid-ventricular long-axis slice. Uptake in each segment was graded on a 5-point scale (0=normal, 1=equivocal, 2=moderate, 3=severe, 4=absence of uptake). The steamboat's images was interpreted separately w ice by two observers without knowledge of each other's findings or results of angiography. A SPECT study was judged abnormal if there were two or more segments with a stress score equal or more than 2. We con eluded that semi-quantitative visual analysis is a simple and reproducible method of interpretation

  5. Normal LVEF measurements are significantly higher in females asassessed by post-stress resting Tc-99m sestamibi gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Kim, Jong Ho; Shin, Eak Kyun

    1999-01-01

    Volume-LVEF relationship is one of the most important factors of automatic EF quantification algorithm from gated myocardial perfusion SPECT(gMPS) (Germano et al. JNM, 1995). Gender difference whereby normal LVEF measurements are higher in females assessed by gMPS (Yao et al. JNM 1997). To validate true physiologic value of LVEF vs sampling or measured error, various parameters were evaluated statistically in both gender and age matched 200 subjects (mean age= 58.41±15.01) with normal LVEF more than 50%, and a low likelihood of coronary artery disease. Correlation between LVEDVi(ml/m2) and LVEF was highly significant (r=-0.62, p<0.0001) with similar correlations noted in both male (r=-0.45, p<0.0001) and female (r=-0.67, p<0.0001) subgroups. By multivariate analysis, LV volume and stroke volume was the most significant factor influencing LVEF in male and female, respectively. In conclusion, there is a significant negative correlation between LV volume and LVEF as measured by Tc-99m gated SPECT. Higher normal LVEF value should be applied to females as assessed by post-stress resting Tc-99m Sestamibi gated myocardial perfusion SPECT

  6. Validation of an in vitro 3D bone culture model with perfused and mechanically stressed ceramic scaffold

    Directory of Open Access Journals (Sweden)

    G Bouet

    2015-05-01

    Full Text Available An engineered three dimensional (3D in vitro cell culture system was designed with the goal of inducing and controlling in vitro osteogenesis in a reproducible manner under conditions more similar to the in vivo bone microenvironment than traditional two-dimensional (2D models. This bioreactor allows efficient mechanical loading and perfusion of an original cubic calcium phosphate bioceramic of highly controlled composition and structure. This bioceramic comprises an internal portion containing homogeneously interconnected macropores surrounded by a dense layer, which minimises fluid flow bypass around the scaffold. This dense and flat layer permits the application of a homogeneous loading on the bioceramic while also enhancing its mechanical strength. Numerical modelling of constraints shows that the system provides direct mechanical stimulation of cells within the scaffold. Experimental results establish that under perfusion at a steady flow of 2 µL/min, corresponding to 3 ≤ Medium velocity ≤ 23 µm/s, mouse calvarial cells grow and differentiate as osteoblasts in a reproducible manner, and lay down a mineralised matrix. Moreover, cells respond to mechanical loading by increasing C-fos expression, which demonstrates the effective mechanical stimulation of the culture within the scaffold. In summary, we provide a “proof-of-concept” for osteoblastic cell culture in a controlled 3D culture system under perfusion and mechanical loading. This model will be a tool to analyse bone cell functions in vivo, and will provide a bench testing system for the clinical assessment of bioactive bone-targeting molecules under load.

  7. Cerebral perfusion abnormalities in therapy-resistant epilepsy in childhood: comparison between EEG, MRI and 99Tcm-ECD brain SPET.

    Science.gov (United States)

    Vattimo, A; Burroni, L; Bertelli, P; Volterrani, D; Vella, A

    1996-01-01

    We performed 99Tcm-ethyl cysteinate dimer (ECD) interictal single photon emission tomography (SPET) in 26 children with severe therapy-resistant epilepsy. All the children underwent a detailed clinical examination, an electroencephalogram (EEG) investigation and brain magnetic resonance imaging (MRI). In 21 of the 26 children, SPET demonstrated brain blood flow abnormalities, in 13 cases in the same territories that showed EEG alterations. MRI showed structural lesions in 6 of the 26 children, while SPET imaging confirmed these abnormalities in only 5 children. The lesion not detected on SPET was shown to be 3 mm thick on MRI. Five symptomatic patients had normal SPET. In one of these patients, the EEG findings were normal and MRI revealed a small calcific nodule (4 mm thick); in the others, the EEG showed non-focal but diffuse abnormalities. These data confirm that brain SPET is sensitive in detecting and localizing hypoperfused areas that could be associated with epileptic foci in this group of patients, even when the MRI image is normal.

  8. Incidental Retrieval of Emotional Contexts in Post-Traumatic Stress Disorder and Depression: An fMRI Study

    Science.gov (United States)

    Whalley, Matthew G.; Rugg, Michael D.; Smith, Adam P. R.; Dolan, Raymond J.; Brewin, Chris R.

    2009-01-01

    In the present study, we used fMRI to assess patients suffering from post-traumatic stress disorder (PTSD) or depression, and trauma-exposed controls, during an episodic memory retrieval task that included non-trauma-related emotional information. In the study phase of the task neutral pictures were presented in emotional or neutral contexts.…

  9. Head-to-Head Visual Comparison between Brain Perfusion SPECT and Arterial Spin-Labeling MRI with Different Postlabeling Delays in Alzheimer Disease.

    Science.gov (United States)

    Kaneta, T; Katsuse, O; Hirano, T; Ogawa, M; Yoshida, K; Odawara, T; Hirayasu, Y; Inoue, T

    2017-08-01

    Arterial spin-labeling MR imaging has been recently developed as a noninvasive technique with magnetically labeled arterial blood water as an endogenous contrast medium for the evaluation of CBF. Our aim was to compare arterial spin-labeling MR imaging and SPECT in the visual assessment of CBF in patients with Alzheimer disease. In 33 patients with Alzheimer disease or mild cognitive impairment due to Alzheimer disease, CBF images were obtained by using both arterial spin-labeling-MR imaging with a postlabeling delay of 1.5 seconds and 2.5 seconds (PLD 1.5 and PLD 2.5 , respectively) and brain perfusion SPECT. Twenty-two brain regions were visually assessed, and the diagnostic confidence of Alzheimer disease was recorded. Among all arterial spin-labeling images, 84.9% of PLD 1.5 and 9% of PLD 2.5 images showed the typical pattern of advanced Alzheimer disease (ie, decreased CBF in the bilateral parietal, temporal, and frontal lobes). PLD 1.5 , PLD 2.5 , and SPECT imaging resulted in obviously different visual assessments. PLD 1.5 showed a broad decrease in CBF, which could have been due to an early perfusion. In contrast, PLD 2.5 did not appear to be influenced by an early perfusion but showed fewer pathologic findings than SPECT. The distinctions observed by us should be carefully considered in the visual assessments of Alzheimer disease. Further studies are required to define the patterns of change in arterial spin-labeling-MR imaging associated with Alzheimer disease. © 2017 by American Journal of Neuroradiology.

  10. Prevalence of silent myocardial ischaemia during exercise stress testing. Its relation to effort tolerance and myocardial perfusion abnormalities.

    Science.gov (United States)

    Fragasso, G; Sciammarella, M G; Rossetti, E E; Xuereb, R G; Xuereb, M; Bonetti, F; Carandente, O M; Margonato, A; Chierchia, S L

    1992-07-01

    The number of underperfused myocardial segments, the extent of coronary artery disease and the severity of impairment of coronary flow reserve were compared in 147 consecutive patients exhibiting painful or painless ischaemic ST segment depression on exercise testing. Of 147 patients, only 61 (41%) experienced angina (group 1) whilst 86 (59%) did not (group 2). In the two groups coronary disease was comparable for both extent and distribution, and neither the location of transient perfusion defects nor their relation to areas of old myocardial necrosis appeared to influence the presence or absence of chest pain. However, exercise duration, exercise time and rate-pressure product at the beginning of ischaemia were lower in group 1. Furthermore, a greater proportion of asymptomatic patients had only one ischaemic segment on 99mTc-MIBI perfusion scintigraphy. We conclude that: (1) in patients with effort angina and coronary disease, the incidence of electrocardiographic silent ischaemic events induced by exercise is similar to that observed in studies based on continuous ECG monitoring. (2) Exertional angina is more frequently associated with greater ischaemic areas and with more severe degrees of impairment of residual coronary flow reserve. (3) The presence of an old myocardial infarction does not appear to influence the incidence of ischaemic cardiac pain.

  11. Diagnostic value of exercise stress testing, dipyridamole stress-echocardiography and perfusion stress-scintigraphy for identification of coronary artery disease in women

    International Nuclear Information System (INIS)

    Debnath, S.; Tyrnovska-Kydreva, R.; Khalacheva, S.; Radoslavova, R.; Stoyanova, N.; Draganov, T.; Elenkova, A.; Garcheva, M.; Shejretova, E.

    1995-01-01

    To compare the value of exercise stress testing (EST), dipyridamole stress echocardiography and 99m Tc-methoxy-isobutyl-isonitrile (MIBI)-planer scintigraphy, 75 female patients with angina pectoris who underwent coronary angiography were studied. Significant (≥50% stenosis) coronary artery disease (CAD) was present in 38 of the patients. EST was performed in all of the patients but dipyridamole echocardiography and MIBI-planer scintigraphy - in 36 of them (22 with and 14 without CAD). Compared with dipyridamole echocardiography, EST and MIBI-planer scintigraphy had a significantly higher sensitivity (74% vs 45%, p<0.01 and 82% vs 45%, p<0.01, respectively). There was no significant difference in sensitivity between EST and MIBI-planer scintigraphy. Dipyridamole echocardiography and MIBI-planer scintigraphy showed a higher specificity than EST (93% vs 54%, p<0.01 and 93% vs 54%, p<0.01, respectively). Diagnostic accuracy of MIBI-planer scintigraphy was higher than that of dipyridamole echocardiography and EST (86% vs 64%, p<0.05 and 86 vs 64%, p<0.01, respectively). Thus, MIBI-planer scintigraphy appears to be superior to EST and dipyridamole echocardiography for the evaluation of CAD in symptomatic women. 20 refs., 2 tabs. (author)

  12. Stress-induced myocardial ischemia is associated with early post-stress left ventricular mechanical dyssynchrony as assessed by phase analysis of {sup 201}Tl gated SPECT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chien-Cheng; Shen, Thau-Yun [Show Chwan Memorial Hospital, Department of Cardiology, Changhua (China); Chang, Ming-Che [Changhua Christian Hospital, Department of Nuclear Medicine, Changhua (China); Hung, Guang-Uei [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Changhua (China); China Medical University, Department of Biomedical Imaging and Radiological Science, Taichung (China); Chen, Wan-Chen [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Changhua (China); Kao, Chia-Hung [China Medical University, Department of Biomedical Imaging and Radiological Science, Taichung (China); Chen, Ji [Emory University School of Medicine, Department of Radiology and Imaging Sciences, Atlanta, GA (United States)

    2012-12-15

    In {sup 201}Tl SPECT myocardial perfusion imaging (MPI) data are acquired shortly after the stress injection to assess early post-stress left ventricle (LV) function. The purpose of this study was to use {sup 201}Tl SPECT MPI to investigate whether stress-induced myocardial ischemia is associated with LV mechanical dyssynchrony. Enrolled in the study were 75 patients who were referred for dipyridamole stress and rest {sup 201}Tl gated SPECT MPI. The early post-stress scan was started 5 min after injection, and followed by the rest scan 4 h later. The patients were divided into three groups: ischemia group (N = 25, summed stress score, SSS, {>=}5, summed rest score, SRS, <5), infarct group (N = 16, SSS {>=}5, SRS {>=}5) and normal group (N = 34, SSS <5, SRS <5). LV dyssynchrony parameters were calculated by phase analysis, and compared between the stress and rest images. In the ischemia group, LV dyssynchrony was significantly larger during stress than during rest. On the contrary, LV dyssynchrony during stress was significantly smaller than during rest in the normal and infarct groups. LV dyssynchrony during rest was significantly larger in the infarct group than in the normal and ischemia groups. There were no significant differences in LV dyssynchrony during rest between the normal and ischemia groups. Stress-induced myocardial ischemia caused dyssynchronous contraction in the ischemic region, leading to a deterioration in LV synchrony. Normal myocardium had more synchronous contraction during stress. The different dyssynchrony pattern between ischemic and normal myocardium early post-stress may aid the diagnosis of coronary artery disease using {sup 201}Tl gated SPECT MPI. (orig.)

  13. Left ventricular function in response to dipyridamole stress: head-to-head comparison between {sup 82}Rubidium PET and {sup 99m}Tc-sestamibi SPECT ECG-gated myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Giorgi, Maria Clementina; Meneghetti, Jose Claudio; Soares, Jose; Izaki, Marisa; Falcao, Andrea; Imada, Rodrigo; Chalela, William; Oliveira, Marco Antonio de; Nomura, Cesar [Department of Radiology and Nuclear Medicine and Molecular Imaging Service - Heart Institute of the University of Sao Paulo Medical School, Sao Paulo (Brazil); Verberne, Hein J. [University of Amsterdam, Department of Nuclear Medicine, Academic Medical Center, P.O. Box 22700, Amsterdam (Netherlands)

    2017-05-15

    Myocardial perfusion imaging (MPI) with {sup 99m}Tc-sestamibi (sestamibi) SPECT and rubidium-82 ({sup 82}Rb) PET both allow for combined assessment of perfusion and left ventricular (LV) function. We sought to compare parameters of LV function obtained with both methods using a single dipyridamole stress dose. A group of 221 consecutive patients (65.2 ± 10.4 years, 52.9% male) underwent consecutive sestamibi and {sup 82}Rb MPI after a single dipyridamole stress dose. Sestamibi and {sup 82}Rb summed rest (SRS), stress (SSS) and difference (SDS) scores, and LV end-diastolic (EDV) and end-systolic (ESV) volumes and left ventricular ejection fraction (LVEF) were compared. Bland-Altman analysis showed that with increasing ESV and EDV the difference between the two perfusion tracers increased both at rest and post-stress. The mean difference in EDV and ESV between the two perfusion tracers at rest could both be independently explained by the {sup 82}Rb SDS and the sestamibi SRS. The combined models explained approximately 30% of the variation in these volumes between the two perfusion tracers (R{sup 2} = 0.261, p = 0.005; R{sup 2} = 0.296, p < 0.001, for EDV and ESV respectively). However, the mean difference in LVEF between sestamibi and {sup 82}Rb showed no significant trend post-stress (R{sup 2} = 0.001, p = 0.70) and only a modest linear increase with increasing LVEF values at rest (R{sup 2} = 0.032, p = 0.009). Differences in left ventricular volumes between sestamibi and {sup 82}Rb MPI increase with increasing volumes. However, these differences did only marginally affect LVEF between sestamibi and {sup 82}Rb. In clinical practice these results should be taken into account when comparing functional derived parameters between sestamibi and {sup 82}Rb MPI. (orig.)

  14. Comparison of rest and adenosine stress quantitative and semi-quantitative myocardial perfusion using magnetic resonance in patients with ischemic heart disease

    DEFF Research Database (Denmark)

    Qayyum, Abbas A; Qayyum, Faiza; Larsson, Henrik B W

    2017-01-01

    software. Linear regression analysis demonstrated that absolute quantitative data correlated stronger to maxSI (rest: r=0.296, p=.193; stress: r=0.583, p=0.011; myocardial perfusion reserve (MPR): r=0.789, pr=0.683, p=0.004) than to upslope (rest: r=0.420, p=0.......058; stress: r=0.096, p=0.704; MPR: r=0.682, p=0.004; and Δ MBF: r=0.055, p=0.804). Absolute quantified MP was able to distinguish between ischemic and non-ischemic territories at rest (left anterior descending artery (LAD): 103.1±11.3mL/100g/min vs. 206.3±98.5mL/100g/min; p=0.001, right coronary artery (RCA......: 206.6±105.1mL/100g/min vs. 273.8±78.0mL/100g/min; p=0.186). The correlation between global maxSI and positron emission tomography data was non-significant at rest and borderline significant at stress (r=0.265, p=0.382 and r=0.601, p=0.050, respectively). Quantified MP may be useful in patients...

  15. Stress-sensitive arterial hypertension, haemodynamic changes and brain metabolites in hypertensive ISIAH rats: MRI investigation.

    Science.gov (United States)

    Seryapina, A A; Shevelev, O B; Moshkin, M P; Markel, A L; Akulov, A E

    2017-05-01

    What is the central question of this study? Stress-sensitive arterial hypertension is considered to be controlled by changes in central and peripheral sympathetic regulating mechanisms, which eventually result in haemodynamic alterations and blood pressure elevation. Therefore, study of the early stages of development of hypertension is of particular interest, because it helps in understanding the aetiology of the disease. What is the main finding and its importance? Non-invasive in vivo investigation in ISIAH rats demonstrated that establishment of sustainable stress-sensitive hypertension is accompanied by a decrease in prefrontal cortex activity and mobilization of hypothalamic processes, with considerable correlations between haemodynamic parameters and individual metabolite ratios. The study of early development of arterial hypertension in association with emotional stress is of great importance for better understanding of the aetiology and pathogenesis of the hypertensive disease. Magnetic resonance imaging (MRI) was applied to evaluate the changes in haemodynamics and brain metabolites in 1- and 3-month-old inherited stress-induced arterial hypertension (ISIAH) rats (10 male rats) with stress-sensitive arterial hypertension and in control normotensive Wistar Albino Glaxo (WAG) rats (eight male rats). In the 3-month-old ISIAH rats, the age-dependent increase in blood pressure was associated with increased blood flow through the renal arteries and decreased blood flow in the lower part of the abdominal aorta. The renal vascular resistance in the ISIAH rats decreased during ageing, although at both ages it remained higher than the renal vascular resistance in WAG rats. An integral metabolome portrait demonstrated that development of hypertension in the ISIAH rats was associated with an attenuation of the excitatory and energetic activity in the prefrontal cortex, whereas in the WAG rats the opposite age-dependent changes were observed. In contrast, in the

  16. Stress-induced ST-segment deviation in relation to the presence and severity of coronary artery disease in patients with normal myocardial perfusion imaging.

    Science.gov (United States)

    Weinsaft, Jonathan W; Manoushagian, Shant J; Patel, Taral; Shakoor, Aqsa; Kim, Robert J; Mirchandani, Sunil; Lin, Fay; Wong, Franklin J; Szulc, Massimiliano; Okin, Peter M; Kligfield, Paul D; Min, James K

    2009-01-01

    To assess the utility of stress electrocardiography (ECG) for identifying the presence and severity of obstructive coronary artery disease (CAD) defined by coronary computed tomographic angiography (CCTA) among patients with normal nuclear myocardial perfusion imaging (MPI). The study population comprised 119 consecutive patients with normal MPI who also underwent CCTA (interval 3.5+/-3.8 months). Stress ECG was performed at the time of MPI. CCTA and MPI were interpreted using established scoring systems, and CCTA was used to define the presence and extent of CAD, which was quantified by a coronary artery jeopardy score. Within this population, 28 patients (24%) had obstructive CAD identified by CCTA. The most common CAD pattern was single-vessel CAD (61%), although proximal vessel involvement was present in 46% of patients. Patients with CAD were nearly three times more likely to have positive standard test responses (1 mm ST-segment deviation) than patients with patent coronary arteries (36 vs. 13%, P=0.007). In multivariate analysis, a positive ST-segment test response was an independent marker for CAD (odds ratio: 2.02, confidence interval: 1.09-3.78, P=0.03) even after adjustment for a composite of clinical cardiac risk factors (odds ratio: 1.85, confidence interval: 1.05-3.23, P=0.03). Despite uniformly normal MPI, mean coronary jeopardy score was three-fold higher among patients with positive compared to those with negative ST-segment response to exercise or dobutamine stress (1.9+/-2.7 vs. 0.5+/-1.4, P=0.03). Stress-induced ST-segment deviation is an independent marker for obstructive CAD among patients with normal MPI. A positive stress ECG identifies patients with a greater anatomic extent of CAD as quantified by coronary jeopardy score.

  17. Multimodal MRI in the characterization of glial neoplasms: the combined role of single-voxel MR spectroscopy, diffusion imaging and echo-planar perfusion imaging

    International Nuclear Information System (INIS)

    Zonari, Paolo; Baraldi, Patrizia; Crisi, Girolamo

    2007-01-01

    Diffusion-weighted imaging (DWI), perfusion-weighted imaging (PWI) and MR spectroscopy (MRS) provide useful data for tumor evaluation. To assess the contribution of these multimodal techniques in grading glial neoplasms, we compared the value of DWI, PWI and MRS in the evaluation of histologically proven high- and low-grade gliomas in a population of 105 patients. Independently for each modality, the following variables were used to compare the tumors: minimum apparent diffusion coefficient (ADC) and maximum relative cerebral blood volume (rCBV) normalized values between tumor and healthy tissue, maximum Cho/Cr ratio and minimum NAA/Cr ratio in tumor, and scored lactate and lipid values in tumor. The Mann-Whitney and Wilcoxon tests were employed to compare DWI, PWI and MRS between tumor types. Logistic regression analysis was used to determine which parameters best increased the diagnostic accuracy in terms of sensitivity, specificity, and positive and negative predictive values. ROC curves were determined for parameters with high sensitivity and specificity to identify threshold values to separate high- from low-grade lesions. Statistically significant differences were found for rCBV tumor/normal tissue ratio, and NAA/Cr ratio in tumor and Cho/Cr ratio in tumor between low- and high-grade tumors. The best performing single parameter for group classification was the normalized rCBV value; including all parameters, statistical significance was reached by rCBV tumor/normal tissue ratio, NAA/Cr tumor ratio and lactate. From the ROC curves, a high probability for a neoplasm to be a high-grade lesion was associated with a rCBV tumor/normal tissue ratio of >1.16 and NAA/Cr tumor ratio of <0.44. Combining PWI and MRS with conventional MR imaging increases the accuracy of the attribution of malignancy to glial neoplasms. The best performing parameter was found to be the perfusion level. (orig.)

  18. Quantitative contrast-enhanced first-pass cardiac perfusion MRI at 3 tesla with accurate arterial input function and myocardial wall enhancement.

    Science.gov (United States)

    Breton, Elodie; Kim, Daniel; Chung, Sohae; Axel, Leon

    2011-09-01

    To develop, and validate in vivo, a robust quantitative first-pass perfusion cardiovascular MR (CMR) method with accurate arterial input function (AIF) and myocardial wall enhancement. A saturation-recovery (SR) pulse sequence was modified to sequentially acquire multiple slices after a single nonselective saturation pulse at 3 Tesla. In each heartbeat, an AIF image is acquired in the aortic root with a short time delay (TD) (50 ms), followed by the acquisition of myocardial images with longer TD values (∼150-400 ms). Longitudinal relaxation rates (R(1) = 1/T(1)) were calculated using an ideal saturation recovery equation based on the Bloch equation, and corresponding gadolinium contrast concentrations were calculated assuming fast water exchange condition. The proposed method was validated against a reference multi-point SR method by comparing their respective R(1) measurements in the blood and left ventricular myocardium, before and at multiple time-points following contrast injections, in 7 volunteers. R(1) measurements with the proposed method and reference multi-point method were strongly correlated (r > 0.88, P < 10(-5)) and in good agreement (mean difference ±1.96 standard deviation 0.131 ± 0.317/0.018 ± 0.140 s(-1) for blood/myocardium, respectively). The proposed quantitative first-pass perfusion CMR method measured accurate R(1) values for quantification of AIF and myocardial wall contrast agent concentrations in 3 cardiac short-axis slices, in a total acquisition time of 523 ms per heartbeat. Copyright © 2011 Wiley-Liss, Inc.

  19. MRI Shows that Exhaustion Syndrome Due to Chronic Occupational Stress is Associated with Partially Reversible Cerebral Changes.

    Science.gov (United States)

    Savic, I; Perski, A; Osika, W

    2018-03-01

    The present study investigates the cerebral effects of chronic occupational stress and its possible reversibility. Forty-eight patients with occupational exhaustion syndrome (29 women) and 80 controls (47 women) underwent structural magnetic resonance imaging (MRI) and neuropsychological testing. Forty-four participants (25 patients, 19 controls) also completed a second MRI scan after 1-2 years. Only patients received cognitive therapy. The stressed group at intake had reduced thickness in the right prefrontal cortex (PFC) and left superior temporal gyrus (STG), enlarged amygdala volumes, and reduced caudate volumes. Except for the caudate volume, these abnormalities were more pronounced in females. They were all related to perceived stress, which was similar for both genders. Thickness of the PFC also correlated with an impaired ability to down-modulate negative emotions. Thinning of PFC and reduction of caudate volume normalized in the follow-up. The amygdala enlargement and the left STG thinning remained. Longitudinal changes were not detected among controls. Chronic occupational stress was associated with partially reversible structural abnormalities in key regions for stress processing. These changes were dynamically correlated with the degree of perceived stress, highlighting a possible causal link. They seem more pronounced in women, and could be a substrate for an increased cerebral vulnerability to stress-related psychiatric disorders. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  20. Magnetic Resonance Imaging of Ventilation and Perfusion in the Lung

    Science.gov (United States)

    Prisk, Gordon Kim (Inventor); Hopkins, Susan Roberta (Inventor); Buxton, Richard Bruce (Inventor); Pereira De Sa, Rui Carlos (Inventor); Theilmann, Rebecca Jean (Inventor); Cronin, Matthew Vincent (Inventor)

    2017-01-01

    Methods, devices, and systems are disclosed for implementing a fully quantitative non-injectable contrast proton MRI technique to measure spatial ventilation-perfusion (VA/Q) matching and spatial distribution of ventilation and perfusion. In one aspect, a method using MRI to characterize ventilation and perfusion in a lung includes acquiring an MR image of the lung having MR data in a voxel and obtaining a breathing frequency parameter, determining a water density value, a specific ventilation value, and a perfusion value in at least one voxel of the MR image based on the MR data and using the water density value to determine an air content value, and determining a ventilation-perfusion ratio value that is the product of the specific ventilation value, the air content value, the inverse of the perfusion value, and the breathing frequency.

  1. Stress-first protocol for myocardial perfusion SPECT imaging with semiconductor cameras: high diagnostic performances with significant reduction in patient radiation doses

    International Nuclear Information System (INIS)

    Perrin, Mathieu; Claudin, Marine; Veran, Nicolas; Morel, Olivier; Besseau, Cyril; Boutley, Henri; Djaballah, Wassila; Poussier, Sylvain; Verger, Antoine; Moulin, Frederic; Imbert, Laetitia; Karcher, Gilles; Marie, Pierre-Yves

    2015-01-01

    Effective doses of 14 mSv or higher are currently being attained in patients having stress and rest myocardial perfusion imaging (MPI) single photon emission computed tomography (SPECT) performed on the same day with conventional protocols. This study aimed to assess the actual reduction in effective doses as well as diagnostic performances for MPI routinely planned with: (1) high-sensitivity cadmium zinc telluride (CZT) cameras, (2) very low injected activities and (3) a stress-first protocol where the normality of stress images may lead to avoiding rest imaging. During a 1-year period, 2,845 patients had MPI on a CZT camera, a single-day stress-first protocol and low injected activities (120 MBq of 99m Tc-sestamibi at stress for 75 kg body weight and threefold higher at rest). The ability to detect > 50 % coronary stenosis was assessed in a subgroup of 149 patients who also had coronary angiography, while the normalcy rate was assessed in a subgroup of 128 patients with a low pretest likelihood of coronary artery disease (<10 %). Overall, 33 % of patients had abnormal MPI of which 34 % were women and 34 % were obese. The mean effective doses and the percentage of exams involving only stress images were: (1) 3.53 ± 2.10 mSv and 37 % in the overall population, (2) 4.83 ± 1.56 mSv and 5 % in the subgroup with angiography and (3) 1.96 ± 1.52 mSv and 71 % in the low-probability subgroup. Sensitivity and global accuracy for identifying the 106 patients with coronary stenosis were 88 and 80 %, respectively, while the normalcy rate was 97 %. When planned with a low-dose stress-first protocol on a CZT camera, MPI provides high diagnostic performances and a dramatic reduction in patient radiation doses. This reduction is even greater in low-risk subgroups with high rates of normal stress images, thus allowing the mean radiation dose to be balanced against cardiac risk in targeted populations. (orig.)

  2. Cost-effectiveness of substituting dual-energy CT for SPECT in the assessment of myocardial perfusion for the workup of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Mathias [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim–Heidelberg University, Mannheim (Germany); Nance, John W. [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Medicine, Division of Cardiology, Medical University of South Carolina, Charleston, SC (United States); Moscariello, Antonio [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Bioimaging and Radiological Sciences, Catholic University of Sacred Heart, “A. Gemelli” Hospital, Rome (Italy); Weininger, Markus; Rowe, Garrett W.; Ruzsics, Balazs [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Kang, Doo Kyoung [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of); Chiaramida, Salvatore A. [Department of Medicine, Division of Cardiology, Medical University of South Carolina, Charleston, SC (United States); Schoenberg, Stefan O.; Fink, Christian [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim–Heidelberg University, Mannheim (Germany); and others

    2012-12-15

    Purpose: We compared cost-effectiveness and potential lifetime benefits of using dual-energy computed tomography (DECT) for myocardial perfusion assessment instead of single photon emission computed tomography (SPECT) for the workup of coronary artery disease (CAD). Materials and methods: A decision and simulation model was developed to estimate cost and health effects of using DECT myocardial perfusion imaging instead of SPECT for identifying patients in need of invasive imaging and possible revascularization. The model was based on the performance indices of stress/rest DECT compared with stress/rest SPECT for detecting myocardial perfusion deficits in 50 patients (mean age 61 ± 10 years) with CAD. Stress/rest perfusion and delayed enhancement cardiac MRI served as reference standard. For DECT a reimbursement of US$1700 was assumed but costs of cardiac MRI were not included in the model. All other actual healthcare costs in these patients were derived from MUSC's hospital billing system. Results: Compared with cardiac MRI, DECT (versus SPECT) had 90% (85%) sensitivity and 71% (58%) specificity for identifying patients with obstructive CAD. Compared with the no imaging and no treatment strategy, routine SPECT gained 13.49 quality-adjusted life-years (QALYs) with an incremental cost-effectiveness ratio (ICER) of US$3557 (in 2010) per QALY. In comparison, DECT ICER was lower (US$3.191 per QALY, p = 0.0002) and an additional 0.64 QALYs was obtained (total of 14.13 QALYs) if compared with the SPECT strategy as well as the no imaging and no treatment strategy. Conclusion: Using DECT as the first-line imaging test for myocardial perfusion for the workup of patients with CAD has the potential to provide gains in QALYs, while lowering costs if compared to routine myocardial perfusion SPECT.

  3. Cost-effectiveness of substituting dual-energy CT for SPECT in the assessment of myocardial perfusion for the workup of coronary artery disease

    International Nuclear Information System (INIS)

    Meyer, Mathias; Nance, John W.; Schoepf, U. Joseph; Moscariello, Antonio; Weininger, Markus; Rowe, Garrett W.; Ruzsics, Balazs; Kang, Doo Kyoung; Chiaramida, Salvatore A.; Schoenberg, Stefan O.; Fink, Christian

    2012-01-01

    Purpose: We compared cost-effectiveness and potential lifetime benefits of using dual-energy computed tomography (DECT) for myocardial perfusion assessment instead of single photon emission computed tomography (SPECT) for the workup of coronary artery disease (CAD). Materials and methods: A decision and simulation model was developed to estimate cost and health effects of using DECT myocardial perfusion imaging instead of SPECT for identifying patients in need of invasive imaging and possible revascularization. The model was based on the performance indices of stress/rest DECT compared with stress/rest SPECT for detecting myocardial perfusion deficits in 50 patients (mean age 61 ± 10 years) with CAD. Stress/rest perfusion and delayed enhancement cardiac MRI served as reference standard. For DECT a reimbursement of US$1700 was assumed but costs of cardiac MRI were not included in the model. All other actual healthcare costs in these patients were derived from MUSC's hospital billing system. Results: Compared with cardiac MRI, DECT (versus SPECT) had 90% (85%) sensitivity and 71% (58%) specificity for identifying patients with obstructive CAD. Compared with the no imaging and no treatment strategy, routine SPECT gained 13.49 quality-adjusted life-years (QALYs) with an incremental cost-effectiveness ratio (ICER) of US$3557 (in 2010) per QALY. In comparison, DECT ICER was lower (US$3.191 per QALY, p = 0.0002) and an additional 0.64 QALYs was obtained (total of 14.13 QALYs) if compared with the SPECT strategy as well as the no imaging and no treatment strategy. Conclusion: Using DECT as the first-line imaging test for myocardial perfusion for the workup of patients with CAD has the potential to provide gains in QALYs, while lowering costs if compared to routine myocardial perfusion SPECT.

  4. Evaluation of myocardial perfusion reserve in patients with CAD using Contrast-Enhanced MRI: A comparison between semiquantitative and quantitative methods

    International Nuclear Information System (INIS)

    Schmitt, M.; Mohrs, O.K.; Petersen, S.E.; Kreitner, K.F.

    2002-01-01

    Objective: Comparison between two semiquantitative methods and a quantitative evaluation of myocardial blood flow (MBF) for assessment of myocardial perfusion reserve (MPR) in patients with CAD. Material and Methods: 9 patients with coronary stenoses>50% were examined with an ECG-gated Saturation Recovery Turbo FLASH sequence by using Gd-DTPA as contrast agent (CA). The entive measurements were performed both during rest and hyperemia induced by adenosine. The up-slopes of the signal-time S(t) curves in the myocardium and left ventricular (LV) cavity were evaluated by a linear fit. MPR was calculated from the original up-slopes of the myocardial S(t) curves and from the up-slopes, which were normalized to the up-slopes of the LV S(t) curves, respectively. For quantification of MBF values, the mathematical model MMID 4 was used and MPR was evaluated from the MBF values. Results: With all tested methods, MPR was reduced in myocardial regions subtended by arteries with stenoses≥70% compared with remote regions. With MMID 4 and the normalized up-slope method, differences between severe ischemic and remote regions were statistically significant. Conclusion: The up-slope method with normalization and quantification with MMID 4 are more sensitive methods to differentiate between remote and ischemic myocardium than the up-slope method without normalization. (orig.) [de

  5. Evaluation by statistical brain perfusion SPECT analysis on MRI findings, kana pick-out test and Mini-Mental State Examination results in patients with forgetfulness

    International Nuclear Information System (INIS)

    Nakatsuka, Hiroki; Matsubara, Ichirou; Ohtani, Haruhiko

    2003-01-01

    The aim of this single photon emission computed tomography (SPECT) study was to determine the abnormality of the regional cerebral blood flow (rCBF) using a three-dimensional stereotactic surface projection (3D-SSP) in 18 patients who were referred to the hospital because of forgetfulness. Two intergroup comparison by 3D-SSP analysis was conducted based on MRI, kana pick-out test and Mini-Mental State Examination (MMSE) results. Of the MRI findings, in the brain atrophy group, rCBF was decreased in the posterior cingulate gyrus, medial temporal structure and parieto-temporal association cortex; these rCBF-decreased areas are similar to the Alzheimer disease pattern. In the group where the MMSE was normal but the kana pick-out test was abnormal, rCBF was decreased in the posterior cingulate gyrus and cinguloparietal transitional area. In the group where both the MMSE and kana pick-out test were abnormal, rCBF was decreased in the parieto-temporal association cortex, temporal cortex and medial temporal structure. These results suggest that 3D-SSP analysis of the SPECT with MMSE and the kana pick-out test provides the possibility of early diagnosis of initial stage of Alzheimer's disease. (author)

  6. Thinner regions of intracranial aneurysm wall correlate with regions of higher wall shear stress: a 7.0 tesla MRI

    Science.gov (United States)

    Blankena, Roos; Kleinloog, Rachel; Verweij, Bon H.; van Ooij, Pim; ten Haken, Bennie; Luijten, Peter R.; Rinkel, Gabriel J.E.; Zwanenburg, Jaco J.M.

    2016-01-01

    Purpose To develop a method for semi-quantitative wall thickness assessment on in vivo 7.0 tesla (7T) MRI images of intracranial aneurysms for studying the relation between apparent aneurysm wall thickness and wall shear stress. Materials and Methods Wall thickness was analyzed in 11 unruptured aneurysms in 9 patients, who underwent 7T MRI with a TSE based vessel wall sequence (0.8 mm isotropic resolution). A custom analysis program determined the in vivo aneurysm wall intensities, which were normalized to signal of nearby brain tissue and were used as measure for apparent wall thickness (AWT). Spatial wall thickness variation was determined as the interquartile range in AWT (the middle 50% of the AWT range). Wall shear stress was determined using phase contrast MRI (0.5 mm isotropic resolution). We performed visual and statistical comparisons (Pearson’s correlation) to study the relation between wall thickness and wall shear stress. Results 3D colored AWT maps of the aneurysms showed spatial AWT variation, which ranged from 0.07 to 0.53, with a mean variation of 0.22 (a variation of 1.0 roughly means a wall thickness variation of one voxel (0.8mm)). In all aneurysms, AWT was inversely related to WSS (mean correlation coefficient −0.35, P<0.05). Conclusions A method was developed to measure the wall thickness semi-quantitatively, using 7T MRI. An inverse correlation between wall shear stress and AWT was determined. In future studies, this non-invasive method can be used to assess spatial wall thickness variation in relation to pathophysiologic processes such as aneurysm growth and –rupture. PMID:26892986

  7. Assessment of Cerebral Hemodynamic Changes in Pediatric Patients with Moyamoya Disease Using Probabilistic Maps on Analysis of Basal/Acetazolamide Stress Brain Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ho Young; Lee, Jae Sung; Kim, Seung Ki; Wang, Kyu Chang; Cho, Byung Kyu; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2008-06-15

    To evaluate the hemodynamic changes and the predictive factors of the clinical outcome in pediatric patients with moyamoya disease, we analyzed pre/post basal/acetazolamide stress brain perfusion SPECT with automated volume of interest (VOIs) method. Total fifty six (M:F=33:24, age 6.7{+-}3.2 years) pediatric patients with moyamoya disease, who underwent basal/acetazolamide stress brain perfusion SPECT within 6 before and after revascularization surgery (encephalo-duro-arterio-synangiosis (EDAS) with frontal encephalo-galeo-synangiosis (EGS) and EDAS only followed on contralateral hemisphere), and followed-up more than 6 months after post-operative SPECT, were included. A mean follow-up period after post-operative SPECT was 33{+-}21 months. Each patient's SPECT image was spatially normalized to Korean template with the SPM2. For the regional count normalization, the count of pons was used as a reference region. The basal/acetazolamide-stressed cerebral blood flow (CBF), the cerebral vascular reserve index (CVRI), and the extent of area with significantly decreased basal/acetazolamide- stressed rCBF than age-matched normal control were evaluated on both medial frontal, frontal, parietal, occipital lobes, and whole brain in each patient's images. The post-operative clinical outcome was assigned as good, poor according to the presence of transient ischemic attacks and/or fixed neurological deficits by pediatric neurosurgeon. In a paired t-test, basal/acetazolamide-stressed rCBF and the CVRI were significantly improved after revascularization (p<0.05). The significant difference in the pre-operative basal/acetazolamide-stressed rCBF and the CVRI between the hemispheres where EDAS with frontal EGS was performed and their contralateral counterparts where EDAS only was done disappeared after operation (p<0.05). In an independent student t-test, the pre-operative basal rCBF in the medial frontal gyrus, the post-operative CVRI in the frontal lobe and the parietal

  8. Chronotropic response to vasodilator-stress in patients submitted to myocardial perfusion imaging: impact on the accuracy in detecting coronary stenosis

    International Nuclear Information System (INIS)

    Gimelli, Alessia; Coceani, Michele; Quaranta, Angela; Emdin, Michele; Liga, Riccardo; Marzullo, Paolo

    2015-01-01

    A lower heart rate response (HRR) during vasodilator MPI has been shown to have a relevant adverse prognostic impact. We sought to evaluate the interaction among individual HRR to vasodilator stress and myocardial perfusion imaging (MPI) accuracy in patients with suspected ischemic heart disease (IHD). One hundred and sixty-five consecutive patients were submitted to vasodilator-stress MPI on a cardiac camera equipped with cadmium-zinc-thelluride detectors and coronary angiography. A coronary stenosis >70 % was considered significant. In every patient, the summed difference score (SDS) was computed from MPI images. Patients were categorized according to the tertiles of the distribution of individual HRR during dipyridamole: ''Group 1'' (HRR < 8 bpm; lowest tertile); ''Group 2'' (8 ≤ HRR ≤ 12 bpm; middle tertile); ''Group 3'' (HRR >12 bpm; highest tertile). Significant coronary artery disease (CAD) was present in 102 (62 %) patients. In the overall population, MPI showed a significant accuracy (AUC: 0.81, 95 % CI 0.74-0.86; p < 0.001) in unmasking the presence of significant coronary stenosis. Interestingly, in patients with a blunted HRR during dipyridamole (''Group 1'') MPI showed a significantly lower sensitivity (68 %) in detecting CAD than in those with a higher HRR (''Group 3'') (91 %, p = 0.007), despite a preserved specificity (76 % vs 77 %, P=NS). Similarly, the correlation among CAD extent and post-stress LV functional stunning was limited to ''Group 3'' patients, while it disappeared in those with blunted HRR. In patients with suspected IHD, MPI sensitivity is strongly influenced by the magnitude of patient heart rate increase to the pharmacologic stressor, suggesting an interaction among blunted HRR and lower accuracy in unmasking CAD. (orig.)

  9. Chronotropic response to vasodilator-stress in patients submitted to myocardial perfusion imaging: impact on the accuracy in detecting coronary stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Gimelli, Alessia; Coceani, Michele; Quaranta, Angela; Emdin, Michele [Fondazione Toscana Gabriele Monasterio, Pisa (Italy); Liga, Riccardo [University Hospital of Pisa, Cardio-Thoracic and Vascular Department, Pisa (Italy); Marzullo, Paolo [Fondazione Toscana Gabriele Monasterio, Pisa (Italy); CNR, Institute of Clinical Physiology, Pisa (Italy)

    2015-11-15

    A lower heart rate response (HRR) during vasodilator MPI has been shown to have a relevant adverse prognostic impact. We sought to evaluate the interaction among individual HRR to vasodilator stress and myocardial perfusion imaging (MPI) accuracy in patients with suspected ischemic heart disease (IHD). One hundred and sixty-five consecutive patients were submitted to vasodilator-stress MPI on a cardiac camera equipped with cadmium-zinc-thelluride detectors and coronary angiography. A coronary stenosis >70 % was considered significant. In every patient, the summed difference score (SDS) was computed from MPI images. Patients were categorized according to the tertiles of the distribution of individual HRR during dipyridamole: ''Group 1'' (HRR < 8 bpm; lowest tertile); ''Group 2'' (8 ≤ HRR ≤ 12 bpm; middle tertile); ''Group 3'' (HRR >12 bpm; highest tertile). Significant coronary artery disease (CAD) was present in 102 (62 %) patients. In the overall population, MPI showed a significant accuracy (AUC: 0.81, 95 % CI 0.74-0.86; p < 0.001) in unmasking the presence of significant coronary stenosis. Interestingly, in patients with a blunted HRR during dipyridamole (''Group 1'') MPI showed a significantly lower sensitivity (68 %) in detecting CAD than in those with a higher HRR (''Group 3'') (91 %, p = 0.007), despite a preserved specificity (76 % vs 77 %, P=NS). Similarly, the correlation among CAD extent and post-stress LV functional stunning was limited to ''Group 3'' patients, while it disappeared in those with blunted HRR. In patients with suspected IHD, MPI sensitivity is strongly influenced by the magnitude of patient heart rate increase to the pharmacologic stressor, suggesting an interaction among blunted HRR and lower accuracy in unmasking CAD. (orig.)

  10. Clinical application of stress/rest myocardial perfusion imaging in the patients with 50%-75% coronary stenosis

    International Nuclear Information System (INIS)

    Han Pingping; Tian Yueqin; Fang Wei; Yang Minfu; Shen Rui; Wei Hongxing; Guo Xinhua; He Zuoxiang

    2011-01-01

    Objective: To evaluate the clinical application of stress/rest Mpi in the patients with 50%-75% coronary artery stenosis. Methods: The criteria for patient selection were that the patients should have at least one main coronary artery with stenosis more than 50%, and the maximal stenosis should be less than 75% according to Cage. The stress/rest Mpi was performed in 2 weeks before or after CAG. A total of 244 patients (178 males, 66 females) with mean age (57 ± 10) years were included in this study. Symptom restriction stress test was used and stress MPI was performed 1-1.5 h after 99 Tc m -MIBI (925 MBq) injection at the exercise peak. Rest MPI was performed within 48-72 h after stress MPI.Myocardial ischemia was diagnosed when there was a reduced uptake or even a defect in 2 different tomographic sections or in the same part of a myocardium in the continuous 2 slices. When there was an irreversible reduced uptake or defect, myocardial infarction was given as the final diagnosis. No reduced uptake or defect in all slices was shown as normal. The impact of MPI images on the selection for optimal clinical therapy plans was also discussed. χ 2 test was used for statistical analysis. Results: A total of 340 coronary arteries with stenosis 50%-75% were found by CAG. According to stress/rest MPI results, 207 patients (84.8%)presented normal, 33 had myocardial ischemia, 3 had myocardial infarction, and 1 had both myocardial infarction and ischemia. In abnormal MPI images, there were 61 ischemic segments and 9 infarct segments,which were associated with 43 stenotic arteries (23 LAD, 10 LCX, and 10 RCA). Patients were divided into 2 groups according to the results of MPI: Group 1 with normal MPI (207/244, 84.8%) and Group 2 with abnormal MPI (37/244, 15.2%). In Group 1, 9 patients underwent coronary artery revascularization (PTCA or CABG), and the others had medical treatment. Eight patients had PTCA and 29 patients had medical treatment in Group 2. There was a

  11. Stress-induced grey matter loss determined by MRI is primarily due to loss of dendrites and their synapses.

    Science.gov (United States)

    Kassem, Mustafa S; Lagopoulos, Jim; Stait-Gardner, Tim; Price, William S; Chohan, Tariq W; Arnold, Jonathon C; Hatton, Sean N; Bennett, Maxwell R

    2013-04-01

    Stress, unaccompanied by signs of post-traumatic stress disorder, is known to decrease grey matter volume (GMV) in the anterior cingulate cortex (ACC) and hippocampus but not the amygdala in humans. We sought to determine if this was the case in stressed mice using high-resolution magnetic resonance imaging (MRI) and to identify the cellular constituents of the grey matter that quantitatively give rise to such changes. Stressed mice showed grey matter losses of 10 and 15 % in the ACC and hippocampus, respectively but not in the amygdala or the retrosplenial granular area (RSG). Concurrently, no changes in the number or volumes of the somas of neurons, astrocytes or oligodendrocytes were detected. A loss of synaptic spine density of up to 60 % occurred on different-order dendrites in the ACC and hippocampus (CA1) but not in the amygdala or RSG. The loss of spines was accompanied by decreases in cumulative dendritic length of neurons of over 40 % in the ACC and hippocampus (CA1) giving rise to decreases in volume of dendrites of 2.6 mm(3) for the former and 0.6 mm(3) for the latter, with no change in the amygdala or RSG. These values are similar to the MRI-determined loss of GMV following stress of 3.0 and 0.8 mm(3) in ACC and hippocampus, respectively, with no changes in the amygdala or RSG. This quantitative study is the first to relate GMV changes in the cortex measured with MRI to volume changes in cellular constituents of the grey matter.

  12. Diffusion and perfusion imaging of bone marrow

    International Nuclear Information System (INIS)

    Biffar, Andreas; Dietrich, Olaf; Sourbron, Steven; Duerr, Hans-Roland; Reiser, Maximilian F.; Baur-Melnyk, Andrea

    2010-01-01

    In diffusion-weighted magnetic resonance imaging (DWI), the observed MRI signal intensity is attenuated by the self-diffusion of water molecules. DWI provides information about the microscopic structure and organization of a biological tissue, since the extent and orientation of molecular motion is influenced by these tissue properties. The most common method to measure perfusion in the body using MRI is T1-weighted dynamic contrast enhancement (DCE-MRI). The analysis of DCE-MRI data allows determining the perfusion and permeability of a biological tissue. DWI as well as DCE-MRI are established techniques in MRI of the brain, while significantly fewer studies have been published in body imaging. In recent years, both techniques have been applied successfully in healthy bone marrow as well as for the characterization of bone marrow alterations or lesions; e.g., DWI has been used in particular for the differentiation of benign and malignant vertebral compression fractures. In this review article, firstly a short introduction to diffusion-weighted and dynamic contrast-enhanced MRI is given. Non-quantitative and quantitative approaches for the analysis of DWI and semiquantitative and quantitative approaches for the analysis of DCE-MRI are introduced. Afterwards a detailed overview of the results of both techniques in healthy bone marrow and their applications for the diagnosis of various bone-marrow pathologies, like osteoporosis, bone tumors, and vertebral compression fractures are described.

  13. Functional assessment of sequential coronary artery fistula and coronary artery stenosis with fractional flow reserve and stress adenosine myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Kuan Leong Yew

    2015-10-01

    Full Text Available Coronary artery fistula is an abnormal connection between one coronary artery to another coronary artery or cardiac chambers. The coronary artery fistula may cause significant shunting of blood and cause “pseudo-stenosis” or “steal phenomenon”. This will also accentuate pre-existing mild-moderate de novo coronary lesions with resultant greater pressure gradient difference across the lesions. Thus, fractional flow reserve can be a useful tool to guide intervention decision on the coronary artery fistula. There are very few published reports regarding the use of FFR to assess coronary artery fistula. In fact, there is no outcome data regarding the deferment of coronary artery fistula intervention when the FFR is not physiologically significant. This case highlighted the use of FFR to evaluate the functional significance of coronary fistula in the setting of ischemia evaluation and it was proven to be safe to defer intervention with good 3 year clinical outcome. Stress adenosine myocardial perfusion imaging correlated with the FFR result.

  14. Comparison of 18F-FET PET and perfusion-weighted MRI for glioma grading. A hybrid PET/MR study

    International Nuclear Information System (INIS)

    Verger, Antoine; Filss, Christian P.; Lohmann, Philipp; Stoffels, Gabriele; Rota Kops, Elena; Sabel, Michael; Wittsack, Hans J.; Galldiks, Norbert; Fink, Gereon R.; Shah, Nadim J.; Langen, Karl-Josef

    2017-01-01

    Both perfusion-weighted MR imaging (PWI) and O-(2- 18 F-fluoroethyl)-L-tyrosine PET ( 18 F-FET) provide grading information in cerebral gliomas. The aim of this study was to compare the diagnostic value of 18 F-FET PET and PWI for tumor grading in a series of patients with newly diagnosed, untreated gliomas using an integrated PET/MR scanner. Seventy-two patients with untreated gliomas [22 low-grade gliomas (LGG), and 50 high-grade gliomas (HGG)] were investigated with 18 F-FET PET and PWI using a hybrid PET/MR scanner. After visual inspection of PET and PWI maps (rCBV, rCBF, MTT), volumes of interest (VOIs) with a diameter of 16 mm were centered upon the maximum of abnormality in the tumor area in each modality and the contralateral unaffected hemisphere. Mean and maximum tumor-to-brain ratios (TBR mean , TBR max ) were calculated. In addition, Time-to-Peak (TTP) and slopes of time-activity curves were calculated for 18 F-FET PET. Diagnostic accuracies of 18 F-FET PET and PWI for differentiating low-grade glioma (LGG) from high-grade glioma (HGG) were evaluated by receiver operating characteristic analyses (area under the curve; AUC). The diagnostic accuracy of 18 F-FET PET and PWI to discriminate LGG from HGG was similar with highest AUC values for TBR mean and TBR max of 18 F-FET PET uptake (0.80, 0.83) and for TBR mean and TBR max of rCBV (0.80, 0.81). In case of increased signal in the tumor area with both methods (n = 32), local hot-spots were incongruent in 25 patients (78%) with a mean distance of 10.6 ± 9.5 mm. Dynamic FET PET and combination of different parameters did not further improve diagnostic accuracy. Both 18 F-FET PET and PWI discriminate LGG from HGG with similar diagnostic performance. Regional abnormalities in the tumor area are usually not congruent indicating that tumor grading by 18 F-FET PET and PWI is based on different pathophysiological phenomena. (orig.)

  15. Comparison of {sup 18}F-FET PET and perfusion-weighted MRI for glioma grading. A hybrid PET/MR study

    Energy Technology Data Exchange (ETDEWEB)

    Verger, Antoine [Forschungszentrum Juelich, Institute of Neuroscience and Medicine (INM-3, -4), Juelich (Germany); Lorraine University, Department of Nuclear Medicine and Nancyclotep Imaging Platform, CHRU Nancy, Nancy (France); Lorraine University, IADI, INSERM, UMR 947, Nancy (France); Filss, Christian P. [Forschungszentrum Juelich, Institute of Neuroscience and Medicine (INM-3, -4), Juelich (Germany); RWTH Aachen University Hospital, Department of Nuclear Medicine, Aachen (Germany); Lohmann, Philipp; Stoffels, Gabriele; Rota Kops, Elena [Forschungszentrum Juelich, Institute of Neuroscience and Medicine (INM-3, -4), Juelich (Germany); Sabel, Michael [University of Duesseldorf, Department of Neurosurgery, Duesseldorf (Germany); Wittsack, Hans J. [University Duesseldorf, Department of Diagnostic and Interventional Radiology, Medical Faculty, Duesseldorf (Germany); Galldiks, Norbert; Fink, Gereon R. [Forschungszentrum Juelich, Institute of Neuroscience and Medicine (INM-3, -4), Juelich (Germany); University of Cologne, Department of Neurology, Cologne (Germany); University of Cologne and Bonn, Center of Integrated Oncology (CIO), Bonn (Germany); Shah, Nadim J. [Forschungszentrum Juelich, Institute of Neuroscience and Medicine (INM-3, -4), Juelich (Germany); RWTH Aachen University Hospital, Department of Neurology, Aachen (Germany); Juelich-Aachen Research Alliance (JARA), Section JARA-Brain, Juelich (Germany); Langen, Karl-Josef [Forschungszentrum Juelich, Institute of Neuroscience and Medicine (INM-3, -4), Juelich (Germany); RWTH Aachen University Hospital, Department of Nuclear Medicine, Aachen (Germany); Juelich-Aachen Research Alliance (JARA), Section JARA-Brain, Juelich (Germany)

    2017-12-15

    Both perfusion-weighted MR imaging (PWI) and O-(2-{sup 18}F-fluoroethyl)-L-tyrosine PET ({sup 18}F-FET) provide grading information in cerebral gliomas. The aim of this study was to compare the diagnostic value of {sup 18}F-FET PET and PWI for tumor grading in a series of patients with newly diagnosed, untreated gliomas using an integrated PET/MR scanner. Seventy-two patients with untreated gliomas [22 low-grade gliomas (LGG), and 50 high-grade gliomas (HGG)] were investigated with {sup 18}F-FET PET and PWI using a hybrid PET/MR scanner. After visual inspection of PET and PWI maps (rCBV, rCBF, MTT), volumes of interest (VOIs) with a diameter of 16 mm were centered upon the maximum of abnormality in the tumor area in each modality and the contralateral unaffected hemisphere. Mean and maximum tumor-to-brain ratios (TBR{sub mean}, TBR{sub max}) were calculated. In addition, Time-to-Peak (TTP) and slopes of time-activity curves were calculated for {sup 18}F-FET PET. Diagnostic accuracies of {sup 18}F-FET PET and PWI for differentiating low-grade glioma (LGG) from high-grade glioma (HGG) were evaluated by receiver operating characteristic analyses (area under the curve; AUC). The diagnostic accuracy of {sup 18}F-FET PET and PWI to discriminate LGG from HGG was similar with highest AUC values for TBR{sub mean} and TBR{sub max} of {sup 18}F-FET PET uptake (0.80, 0.83) and for TBR{sub mean} and TBR{sub max} of rCBV (0.80, 0.81). In case of increased signal in the tumor area with both methods (n = 32), local hot-spots were incongruent in 25 patients (78%) with a mean distance of 10.6 ± 9.5 mm. Dynamic FET PET and combination of different parameters did not further improve diagnostic accuracy. Both {sup 18}F-FET PET and PWI discriminate LGG from HGG with similar diagnostic performance. Regional abnormalities in the tumor area are usually not congruent indicating that tumor grading by {sup 18}F-FET PET and PWI is based on different pathophysiological phenomena. (orig.)

  16. The potential of infant fMRI research and the study of early life stress as a promising exemplar

    Directory of Open Access Journals (Sweden)

    Alice M. Graham

    2015-04-01

    Full Text Available Functional magnetic resonance imaging (fMRI research with infants and toddlers has increased rapidly over the past decade, and provided a unique window into early brain development. In the current report, we review the state of the literature, which has established the feasibility and utility of task-based fMRI and resting state functional connectivity MRI (rs-fcMRI during early periods of brain maturation. These methodologies have been successfully applied beginning in the neonatal period to increase understanding of how the brain both responds to environmental stimuli, and becomes organized into large-scale functional systems that support complex behaviors. We discuss the methodological challenges posed by this promising area of research. We also highlight that despite these challenges, early work indicates a strong potential for these methods to influence multiple research domains. As an example, we focus on the study of early life stress and its influence on brain development and mental health outcomes. We illustrate the promise of these methodologies for building on, and making important contributions to, the existing literature in this field.

  17. A longitudinal fMRI investigation in acute post-traumatic stress disorder (PTSD).

    Science.gov (United States)

    Ke, Jun; Zhang, Li; Qi, Rongfeng; Li, Weihui; Hou, Cailan; Zhong, Yuan; He, Zhong; Li, Lingjiang; Lu, Guangming

    2016-11-01

    Background Neuroimaging studies have implicated limbic, paralimbic, and prefrontal cortex in the pathophysiology of chronic post-traumatic stress disorder (PTSD). However, little is known about the neural substrates of acute PTSD and how they change with symptom improvement. Purpose To examine the neural circuitry underlying acute PTSD and brain function changes during clinical recovery from this disorder. Material and Methods Nineteen acute PTSD patients and nine non-PTSD subjects who all experienced a devastating mining accident underwent clinical assessment as well as functional magnetic resonance imaging (fMRI) scanning while viewing trauma-related and neutral pictures. Two years after the accident, a subgroup of 17 patients completed a second clinical evaluation, of which 13 were given an identical follow-up scan. Results Acute PTSD patients demonstrated greater activation in the vermis and right posterior cingulate, and greater deactivation in the bilateral medial prefrontal cortex and inferior parietal lobules than controls in the traumatic versus neutral condition. At follow-up, PTSD patients showed symptom reduction and decreased activation in the right middle frontal gyrus, bilateral posterior cingulate/precuneus, and cerebellum. Correlation results confirmed these findings and indicated that brain activation in the posterior cingulate/precuneus and vermis was predictive of PTSD symptom improvement. Conclusion The findings support the involvement of the medial prefrontal cortex, inferior parietal lobule, posterior cingulate, and vermis in the pathogenesis of acute PTSD. Brain activation in the vermis and posterior cingulate/precuneus appears to be a biological marker of recovery potential from PTSD. Furthermore, decreased activation of the middle frontal gyrus, posterior cingulate/precuneus, and cerebellum may reflect symptom improvement.

  18. Serial cerebral hemodynamic change after extracranial-intracranial (EC-IC) bypass surgery: evaluated by acetazolamide stress brain perfusion SPECT(acz-SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Il Ki; Kim, Jae Seung; Ahn, Jae Sung; Im, Ki Chun; Kim, Euy Nyong; Mun, Dae Hyeog [Asan Medical Center, Seoul (Korea, Republic of)

    2005-07-01

    We evaluated serial cerebral hemodynamic changes after EC-IC bypass surgery in symptomatic pts with atherosclerotic occlusion of internal carotid (lCA) or mid-cerebral artery (MCA) using Acz-SPECT. 25 symptomatic pts (M/F 19/6, 53{+-}10 y) with ICA and MCA occlusion (16 uni - and 9 bilateral) prospectively underwent Acz-SPECT using Tc-99m ECD before and 1 week after EC-IC bypass surgery. Of these, 16 underwent additional f/u Acz-SPECT 5 mo later. Cerebral perfusion and perfusion reserve of MCA territory were evaluated visually and SPECT findings were classified into 4 groups: N/N; R/N; N/R; and R/R (perfusion/perfusion reserve: N = normal, R = reduced). For semiquantitative analysis, all SPECT images were normalized to MNI template and mean counts of MCA territory and cerebellum were obtained by AAL. Cerebral perfusion index (PI =C{sub region}/C{sub cere}) and perfusion reserve index (RI = (PI{sub Acz} - PI{sub basal}) /Pl{sub basal}) were calculated. Preop SPECT findings of ipsilateral MCA in 25 pts were R/N (4%), N/R (12%), and R/R (84% ). Early postop SPECT showed improvement of perfusion (26%) and/or reserve (68%) in ipsilateral MCA. Of 16 pts with 5mo f/u SPECT, 6 (38%) showed further improvement of perfusion or reserve. However, 4 (25%) showed aggravation of perfusion and one of these underwent revision surgery. Preop PI (1.1{+-}0.1) and RI (0.11{+-}0.07) of ipsilateral MCA were significantly lower than those of contralateral hemispheres (p<0.05). After surgery, PIs of bilateral MCA did not change at early postop period but improved in ipsilateral MCA at 5mo. Rls of ipsilateral MCA increased significantly (68%) at early postop period (P<0.001) and then did not changed. Cerebral perfusion and perfusion reserve changed with different manner during 5 mo after bypass surgery and perfusion reserve changed more dramatically than perfusion. Acz-SPECT is a feasible method for evaluating cerebral hemodynamic change after EC-IC bypass surgery.

  19. Biodistribution and radiation dosimetry of {sup 82}Rb at rest and during peak pharmacological stress in patients referred for myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, Chad R.R.N.; DeKemp, Robert A. [Carleton University, Ottawa, ON (Canada); University of Ottawa Heart Institute, Ottawa, ON (Canada); Hill, Jeremy [Consultant to Jubilant DraxImage, Kirkland, QC (Canada); Ziadi, M.C.; Beanlands, Rob S.B. [University of Ottawa Heart Institute, Ottawa, ON (Canada)

    2015-03-28

    {sup 82}Rb is an ultra-short-lived positron emitter used for myocardial blood flow quantification with PET imaging. The aim of this study was to quantify the biodistribution and radiation dosimetry in patients with coronary disease and in healthy normal volunteers. A total of 30 subjects, 26 patients with known or suspected coronary artery disease (CAD) and four healthy volunteers were injected with {sup 82}Rb chloride at 10 MBq/kg followed by a 10-min dynamic PET scan. Chest scans at rest were acquired in all subjects, as well as one additional biodistribution scan of the head, neck, abdomen, pelvis or thighs. Chest scans under stress were acquired in 25 of the CAD patients. {sup 82}Rb time-integrated activity coefficients were determined in 22 source organs using volume of interest analysis, including corrections for partial-volume losses. The mean time-integrated activity coefficients were used to calculate the whole-body effective dose using tissue weighting factors from the International Commission on Radiological Protection (ICRP) Publications 60 and 103. A total of 283 organ time-integrated activity coefficients were calculated, with a minimum of four values per source organ. The rest and stress mean effective dose was 0.8 mSv/GBq, according to the most recent ICRP definition. Using 10 MBq/kg for 3D PET imaging, the effective dose to a gender-averaged reference person (60 kg female and 73 kg male) is 1.1 mSv for a complete rest and stress perfusion study. For 2D PET using a typical injected activity of 1.1 to 2.2 GBq each for rest and stress, the effective dose for a complete study is 1.8 to 3.5 mSv. The current effective dose estimate in CAD patients is four times lower than the values reported previously by the ICRP, and about 35 % lower than previous in vivo studies in young healthy subjects. (orig.)

  20. Safety and tolerability of adenosine stress myocardial perfusion scintigraphy in the evaluation of coronary artery disease in the elderly patients - A case control study

    International Nuclear Information System (INIS)

    Gnanasegaran, G.; Malcolm, M.; Rossiter, A.; McCool, D.; Hilson, A.J.W.; Buscombe, J.R.

    2006-01-01

    Elderly patients referred for evaluation of chest pain are often unable to undertake adequate exercise for exercise stress testing. The aim of this retrospective study was to analyze haemodynamic effects and assess the safety of adenosine stress myocardial perfusion scintigraphy (MPS) in the elderly. Records of 380 Patients (Age range=30-93 years) were reviewed. These were divided into two groups, Group-A with 190 patients who were above 65 years of age and Group-B with 190 patients who were equal or below the age of 65 years, and who had undergone adenosine stress MPS. The two groups were matched for major risk factors and clinical presentations. Symptoms (flushing, headache, chest pain, dyspnoea, neck pain) were recorded throughout the adenosine infusion. Baseline blood pressure, heart rate and ECG were recorded and monitored throughout the study. A total of 167 out of 380 patients (44%) had side effects, 86 of them belonged to Group-A and 81 of them belonged to Group-B. Flushing occurred in 33% of patients in Group-A and 43% of patients in Group-B. Seventeen percent of patients in Group-A had chest pain, while this was encountered in 27% of patients in Group-B. Dyspnoea was recorded in 32% of patients from Group-A, while it was encountered in 21% of patients belonging to Group-B. Neck pain was experienced by 8.4% in Group-A and 15% in Group-B. All of these findings were statistically significant (p<0.05). Several other side effects were also encountered which included headache (Group-A: 14% and Group-B: 21%), abdominal discomfort (Group-A: 19% and Group-B: 23%), Nausea and/or vomiting (Group-A: 4.7% and Group-B: 7.3%). ECG changes were noted in both groups (Group-A: 14% and Group-B: 12%). None of these were found to be statistically significant. Based on this retrospective study, the authors concluded that Adenosine stress MPS is a safe method for the evaluation of coronary artery disease (CAD) in elderly patients and is well tolerated. Most side effects were

  1. Myocardial perfusion as an indicator of graft patency after coronary artery bypass surgery

    International Nuclear Information System (INIS)

    Kolibash, A.J.; Call, T.D.; Bush, C.A.; Tetalman, M.R.; Lewis, R.P.

    1980-01-01

    Stress and resting myocardial perfusion were assessed in 38 patients who received 96 grafts. Stress perfusion was evaluated with thallium-201 and resting myocardial blood flow distribution with radiolabeled particles. When both stress and rest perfusion were normal, graft patency was 82% (51 of 62 grafts). Graft patency was also high (81%, 13 of 16) in areas where stress perfusion abnormalities resolved or become less apparent at rest. However, when stress perfusion defects remained unchanged at rest, the graf was likely to be occuluded (73%, 11 of 15). Maintenance of normal rest perfusion or improvement of rest perfusion postoperatively was also associated with a high graft patency rate (80%, 35 of 44), whereas the development of new rest perfusion defects postoperatively implied graft occlusion

  2. Body Mass Index, Metabolic Factors, and Striatal Activation During Stressful and Neutral-Relaxing States: An fMRI Study

    OpenAIRE

    Jastreboff, Ania M; Potenza, Marc N; Lacadie, Cheryl; Hong, Kwangik A; Sherwin, Robert S; Sinha, Rajita

    2010-01-01

    Stress is associated with alterations in neural motivational-reward pathways in the ventral striatum (VS), hormonal/metabolic changes, and weight increases. The relationship between these different factors is not well understood. We hypothesized that body mass index (BMI) status and hormonal/metabolic factors would be associated with VS activation. We used functional magnetic resonance imaging (fMRI) to compare brain responses of overweight and obese (OW/OB: BMI ⩾25 kg/m2: N=27) individuals w...

  3. A comparative study between TL-201 SPECT myocardial perfusion scintigraphy and dobutamine stress echocardiography in the detection of coronary artery disease at the Philippine Heart Center

    International Nuclear Information System (INIS)

    Ogbac, R.V.; Martinez, A.O.; Obaldo, J.M.; Monzon, O.P.; Torres, J.F.; Rondilla, L.W.S.; Yap, J.S.; Flores, V.B.; Santos, R.J.; Jara, R.D.

    1996-01-01

    Although thallium-201 SPECT myocardial perfusion scintigraphy (MPS) has shown considerable accuracy for the detection of coronary artery disease (CAD), dobutamine stress echocardiography (DSE), a relatively new method for the detection of CAD had been recently utilized at the Philippine Heart Center. To assess its diagnostic worth versus that of thallium-201 spect myocardial scintigraphy (MPS), we studied 18 patients who underwent both procedures. Coronary angiography (CA) was used as the gold standard. MPS was performed with maximal treadmill exercise or with dipyridamole (0.568 mg/kg over 4 minutes) and Tl-201 was injected at peak stress. DSE was performed by infusing dobutamine at an increment of 5 μg/kg/min up to a maximum of 40. Atropine (0.01%) was added when 85% of maximum predicted heart rate is not achieved. Significant stenosis (>70%) was found in 16 out of 18 patients by CA. The sensitivity for the presence of CAD was 88% (14/16) and 69% (11/16) for MPS and DSE respectively. Specificity was 100% (2/2) for both. PPV was 100% for both while NPV was 50% and 29% for MPS and DSE respectively. Diagnostic accuracies were 89% and 72% for MPS and DSE respectively (P>0.05). Sensitivity for detecting left anterior descending artery (LAD) lesion was 71% 64% for MPS and DSE respectively; specificity was 75% and 100% respectively. For the left circumplex artery (LCX) lesion, both MPS and DSE had a sensitivity of 62% and specificity of 60%. Likewise for the right coronary artery (RCA) lesion, both had a sensitivity of 66% and specificity of 50%. Diagnostic accuracies were equal for both tests at 72% for LAD; 61% for LCX; and 61% for RCA. Kappa tests for association shows ρ values of >0.05 for overall and individual CAD detection suggesting no significant difference between MPS and DSE. Although there is a trend showing better detection of CAD with MPS, this particular study shows that both tests are comparable with regards to detection of the presence of CAD and of

  4. Low-dose single acquisition rest {sup 99m}Tc/stress {sup 201}Tl myocardial perfusion SPECT protocol: phantom studies and clinical validation

    Energy Technology Data Exchange (ETDEWEB)

    Dey, Thomas [RWTH Aachen University, Institute of Imaging and Computer Vision, Aachen (Germany); Backus, Barbra E.; Romijn, R.Leo [St. Antonius Hospital, Department of Nuclear Medicine, Nieuwegein (Netherlands); Wieczorek, Herfried [Philips Research, Eindhoven (Netherlands); Verzijlbergen, J.F. [St. Antonius Hospital, Department of Nuclear Medicine, Nieuwegein (Netherlands); Erasmus Medical Center, Department of Nuclear Medicine, Rotterdam (Netherlands)

    2014-03-15

    We developed and tested a single acquisition rest {sup 99m}Tc-sestamibi/stress {sup 201}Tl dual isotope protocol (SDI) with the intention of improving the clinical workflow and patient comfort of myocardial perfusion single photon emission computed tomography (SPECT). The technical feasibility of SDI was evaluated by a series of anthropomorphic phantom studies on a standard SPECT camera. The attenuation map was created by a moving transmission line source. Iterative reconstruction including attenuation correction, resolution recovery and Monte Carlo simulation of scatter was used for simultaneous reconstruction of dual tracer distribution. For clinical evaluation, patient studies were compared to stress {sup 99m}Tc and rest {sup 99m}Tc reference images acquired in a 2-day protocol. Clinical follow-up examinations like coronary angiography (CAG) and fractional flow reserve (FFR) were included in the assessment if available. Phantom studies demonstrated the technical feasibility of SDI. Artificial lesions inserted in the phantom mimicking ischaemia could be clearly identified. In 51/53 patients, the image quality was adequate for clinical evaluation. For the remaining two obese patients with body mass index > 32 the injected {sup 201}Tl dose of 74 MBq was insufficient for clinical assessment. In answer to this the {sup 201}Tl dose was adapted for obese patients in the rest of the study. In 31 patients, SDI and {sup 99m}Tc reference images resulted in equivalent clinical assessment. Significant differences were found in 20 patients. In 18 of these 20 patients additional examinations were available. In 15 patients the diagnosis based on the SDI images was confirmed by the results of CAG or FFR. In these patients the SDI images were more accurate than the {sup 99m}Tc reference study. In three patients minor ischaemic lesions were detected by SDI but were not confirmed by CAG. In one of these cases this was probably caused by pronounced apical thinning. For two patients

  5. Low-dose single acquisition rest 99mTc/stress 201Tl myocardial perfusion SPECT protocol: phantom studies and clinical validation

    International Nuclear Information System (INIS)

    Dey, Thomas; Backus, Barbra E.; Romijn, R.Leo; Wieczorek, Herfried; Verzijlbergen, J.F.

    2014-01-01

    We developed and tested a single acquisition rest 99m Tc-sestamibi/stress 201 Tl dual isotope protocol (SDI) with the intention of improving the clinical workflow and patient comfort of myocardial perfusion single photon emission computed tomography (SPECT). The technical feasibility of SDI was evaluated by a series of anthropomorphic phantom studies on a standard SPECT camera. The attenuation map was created by a moving transmission line source. Iterative reconstruction including attenuation correction, resolution recovery and Monte Carlo simulation of scatter was used for simultaneous reconstruction of dual tracer distribution. For clinical evaluation, patient studies were compared to stress 99m Tc and rest 99m Tc reference images acquired in a 2-day protocol. Clinical follow-up examinations like coronary angiography (CAG) and fractional flow reserve (FFR) were included in the assessment if available. Phantom studies demonstrated the technical feasibility of SDI. Artificial lesions inserted in the phantom mimicking ischaemia could be clearly identified. In 51/53 patients, the image quality was adequate for clinical evaluation. For the remaining two obese patients with body mass index > 32 the injected 201 Tl dose of 74 MBq was insufficient for clinical assessment. In answer to this the 201 Tl dose was adapted for obese patients in the rest of the study. In 31 patients, SDI and 99m Tc reference images resulted in equivalent clinical assessment. Significant differences were found in 20 patients. In 18 of these 20 patients additional examinations were available. In 15 patients the diagnosis based on the SDI images was confirmed by the results of CAG or FFR. In these patients the SDI images were more accurate than the 99m Tc reference study. In three patients minor ischaemic lesions were detected by SDI but were not confirmed by CAG. In one of these cases this was probably caused by pronounced apical thinning. For two patients no relevant clinical follow

  6. Improved exercise myocardial perfusion during lidoflazine therapy

    International Nuclear Information System (INIS)

    Shapiro, W.; Narahara, K.A.; Park, J.

    1983-01-01

    Lidoflazine is a synthetic drug with calcium-channel blocking effects. In a study of 6 patients with severe classic angina pectoris, single-blind administration of lidoflazine was associated with improved myocardial perfusion during exercise as determined by thallium-201 stress scintigraphy. These studies demonstrate that lidoflazine therapy is associated with relief of angina, an increased physical work capacity, and improved regional myocardial perfusion during exercise

  7. Implications of oxidative stress in the brain plasticity originated by fasting: a BOLD-fMRI study.

    Science.gov (United States)

    Belaïch, Rachida; Boujraf, Saïd; Benzagmout, Mohammed; Magoul, Rabia; Maaroufi, Mustapha; Tizniti, Siham

    2017-11-01

    The goal of this study was assessing the intermittent fasting effect on brain plasticity and oxidative stress (OS) using blood-oxygenation-level dependent (BOLD)-functional magnetic resonance image (fMRI) approach. Evidences of physiological and molecular phenomena involved in this process are discussed and compared to reported literature. Six fully healthy male non-smokers volunteered in this study. All volunteers were right handed, and have an equilibrated, consistent and healthy daily nutritional habit, and a healthy lifestyle. Participants were allowed consuming food during evening and night time while fasting with self-prohibiting food and liquids during 14 hours/day from sunrise to sunset. All participants underwent identical brain BOLD-fMRI protocol. The images were acquired in the Department of Radiology and Clinical Imaging of the University Hospital of Fez, Fez, Morocco. The anatomical brain and BOLD-fMRIs were acquired using a 1.5-Tesla scanner (Signa, General Electric, Milwaukee, United States). BOLD-fMRI image acquisition was done using single-shot gradient echo echo-planer imaging sequence. BOLD-fMRI paradigm consisted of the motor task where volunteers were asked to perform finger taping of the right hand. Two BOLD-fMRI scan sessions were performed, the first one between the 5th and 10th days preceding the start of fasting and the second between days 25th and 28th of the fasting month. All sessions were performed between 3:30 PM and 5:30 PM. Although individual maps were originated from different individual participants, they cover the same anatomic area in each case. Image processing and statistical analysis were conducted with Statistical Parameter Mapping version 8 (2008, Welcome Department of Cognitive Neurology, London UK). The maximal BOLD signal changes were calculated for each subject in the motor area M1; Activation maps were calculated and overlaid on the anatomical images. Group analysis of the data was performed, and the average volume

  8. Assessment of brain activities during an emotional stress state using fMRI

    International Nuclear Information System (INIS)

    Hayashi, Takuto; Mizuno-Matsumoto, Yuko; Kawasaki, Aika; Kato, Makoto; Murata, Tsutomu

    2011-01-01

    We investigated cerebrum activation using functional magnetic resonance imaging during a mental stress state. Thirty-four healthy adults participated. Before the experiment, we assessed their stress states using the Stress Self-rating Scale and divided the participants into Stress and Non-stress groups. The experiment consisted of 6 trials. Each trial consisted of a 20-s block of emotional audio-visual stimuli (4-s stimulation x 5 slides) and a fixation point. These processes were performed 3 times continuously (Relaxed, Pleasant, Unpleasant stimuli) in a random order. These results showed that the Non-stress group indicated activation of the amygdala and hippocampus in the Pleasant and Unpleasant stimuli while the Stress group indicated activation of the hippocampus in Pleasant stimuli, and the amygdala and hippocampus in Unpleasant stimuli. These findings suggested that the mental stress state engages the reduction of emotional processing. Also, the responsiveness of the memory system remained during and after the emotional stress state. (author)

  9. Cost effectiveness of coronary angiography and calcium scoring using CT and stress MRI for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Dewey, Marc; Hamm, Bernd

    2007-01-01

    We compared the cost effectiveness of recent approaches [coronary angiography and calcium scoring using computed tomography (CT) and stress magnetic resonance imaging (MRI)] to the diagnosis of coronary artery disease (CAD) with those of the traditional diagnostic modalities [conventional angiography (CATH), exercise ECG, and stress echocardiography] using a decision tree model. For patients with a 10% to 50% pretest likelihood of coronary artery disease, non-invasive coronary angiography using CT was the most cost effective approach, with costs per correctly identified CAD patient of EUR4,435 (10% likelihood) to EUR1,469 (50% likelihood). Only for a pretest likelihood of 30% to 40% was calcium scoring using CT more cost effective than any of the traditional diagnostic modalities, while MRI was not cost effective for any pretest likelihood. At a pretest likelihood of 60%, CT coronary angiography and CATH were equally effective, while CATH was most cost effective for a pretest likelihood of at least 70%. In conclusion, up to a pretest likelihood for coronary artery disease of 50%, CT coronary angiography is the most cost-effective procedure, being superior to the other new modalities and the most commonly used traditional diagnostic modalities. With a very high likelihood for disease (above 60%), CATH is the most effective procedure from the perspective of society. (orig.)

  10. Functional MRI of the kidneys

    OpenAIRE

    Zhang, Jeff L.; Rusinek, Henry; Chandarana, Hersh; Lee, Vivian S.

    2013-01-01

    Renal function is characterized by different physiologic aspects, including perfusion, glomerular filtration, interstitial diffusion and tissue oxygenation. MRI shows great promise in assessing these renal tissue characteristics noninvasively. The last decade has witnessed a dramatic progress in MRI techniques for renal function assessment. This article briefly describes relevant renal anatomy and physiology, reviews the applications of functional MRI techniques for the diagnosis of renal dis...

  11. Efficacy and safety of a novel pharmacological stress test agent-higenamine in radionuclide myocardial perfusion imaging: phase Ⅱ clinical trial

    International Nuclear Information System (INIS)

    Du Yanrong; Li Fang; Wang Qian; Li Dianfu; Long Mingqing; Liu Yimin; Li Bilu

    2014-01-01

    of diastolic blood pressure. Either HG or Ad induced significantly increased HR during administration and 5 min after administration. The clinical laboratory profile (hematology,serum chemistry, and urinalysis) was either normal or with no significant change. A total of 176 side effects (e.g, dyspnea, short breath, palpitation, dizziness,headache) were found related to HG (69.2%, 83/120) and Ad (77.5%, 93/120) administration (χ 2 =2.1307, P>0.05), which were mostly mild and transient. Conclusion: HG is a safe and effective pharmacological stress test agent as compared to adenosine for the detection of CAD with SPECT perfusion imaging. (authors)

  12. The advantage of high relaxivity contrast agents in brain perfusion

    International Nuclear Information System (INIS)

    Cotton, F.; Hermier, M.

    2006-01-01

    Accurate MRI characterization of brain lesions is critical for planning therapeutic strategy, assessing prognosis and monitoring response to therapy. Conventional MRI with gadolinium-based contrast agents is useful for the evaluation of brain lesions, but this approach primarily depicts areas of disruption of the blood-brain barrier (BBB) rather than tissue perfusion. Advanced MR imaging techniques such as dynamic contrast agent-enhanced perfusion MRI provide physiological information that complements the anatomic data available from conventional MRI. We evaluated brain perfusion imaging with gadobenate dimeglumine (Gd-BOPTA, MultiHance; Bracco Imaging, Milan, Italy). The contrast-enhanced perfusion technique was performed on a Philips Intera 1.5-T MR system. The technique used to obtain perfusion images was dynamic susceptibility contrast-enhanced MRI, which is highly sensitive to T2* changes. Combined with PRESTO perfusion imaging, SENSE is applied to double the temporal resolution, thereby improving the signal intensity curve fit and, accordingly, the accuracy of the derived parametric images. MultiHance is the first gadolinium MR contrast agent with significantly higher T1 and T2 relaxivities than conventional MR contrast agents. The higher T1 relaxivity, and therefore better contrast-enhanced T1-weighted imaging, leads to significantly improved detection of BBB breakdown and hence improved brain tumor conspicuity and delineation. The higher T2 relaxivity allows high-quality T2*-weighted perfusion MRI and the derivation of good quality relative cerebral blood volume (rCBV) maps. We determined the value of MultiHance for enhanced T2*-weighted perfusion imaging of histologically proven (by surgery or stereotaxic biopsy) intraaxial brain tumors (n=80), multiple sclerosis lesions (n=10), abscesses (n=4), neurolupus (n=15) and stroke (n=16). All the procedures carried out were safe and no adverse events occurred. The acquired perfusion images were of good quality in

  13. [Myocardial microcirculation in humans--new approaches using MRI].

    Science.gov (United States)

    Wacker, Christian M; Bauer, Wolfgang R

    2003-03-01

    oxygen breathing. In patients with CAD, myocardial regions with decreased perfusion reserve could be identified. perfusion reserve could be identified. Performing the described spin-labeling technique with an intravascular CA facilitates the determination of the intra-extracapillary water proton exchange frequency and the RBV. In a patient study, the effect of the intravascular CA Feruglose (Amersham) on relaxation rate in myocardium (R1(myo)) in the steady state was investigated (Figure 1). The dependence of R1(myo) on R1(blood) was characterized and compared with a theoretical model which allowed determination of the intra-extracapillary water proton exchange frequency (f = 0.48 s(-1)) and the intracapillary blood volume (RBV = 12.9%). A linear response range of Delta R1(myo) on Delta R1(blood) was estimated which, in future studies, will allow the determination of RBV with intravascular CA (Figure 2). T2* We anticipated that poststenotic vasodilatation implies a capillary recruitment. Almost all (i.e., > 90%) of intramyocardial blood residues in that type of vessel. Due to their large arteriovenous oxygenation difference, myocardial capillaries contain considerable amounts of deoxyhemoglobin (Figure 3). Hence, in regions with autoregulatory capillary recruitment the tissue concentration of deoxyhemoglobin should be elevated when compared to myocardium supplied by a normal vessel (Figure 5b). Due to its paramagnetic property and its intravascular confinement, the natural CA deoxyhemoglobin may be assessed by susceptibility sensitive, or also called blood oxygenation level-dependent (BOLD) MRI. For T2* measurements, a segmented gradient echo pulse sequence was used, which acquired ten successive gradient echoes per rf excitation in a single breathhold. In volunteers, there was an increase in T2* of about 10% under dipyridamole-induced stress (Figure 4). This means a decrease of the intracapillary deoxyhemoglobin concentration, whereas the oxygen consumption under

  14. Perfusion CT in childhood stroke—Initial observations and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Zebedin, D., E-mail: doris.zebedin@medunigraz.at [Division of Pediatric Radiology, Department of Radiology, University Hospital LKH Graz (Austria); Sorantin, E.; Riccabona, M. [Division of Pediatric Radiology, Department of Radiology, University Hospital LKH Graz (Austria)

    2013-07-15

    Introduction: To report the preliminary results of contrast-enhanced perfusion multi-detector CT for diagnoses of perfusion disturbances in children with clinical suspicion of stroke. Patients and methods: Within the last two years emergency perfusion CT was performed in ten children (age: 8–17 years, male:female = 3:7) for assessment of suspected childhood stroke. These intracranial perfusion CT, intracranial CT-digital subtraction angiography (CT-DSA) and extracranial CT-angiography (CTA) studies were retrospectively reviewed and compared with MRI, follow-up CT, catheter angiography and final clinical diagnosis. The total dose length product (DLP) for the entire examination was recorded. The image quality of perfusion CT-maps, CT-DSA and CTA were evaluated with a subjective three-point scale ranging from very good to non-diagnostic image quality rating perfusion disturbance, intracranial peripheral vessel depiction, and motion- or streak artifacts. Results: In nine of ten children perfusion CT showed no false positive or false negative results. In one of ten children suffering from migraine focal hypo-perfusion was read as perfusion impairment potentially indicating early stroke, but MRI and MRA follow-up were negative. Overall, perfusion-CT with CT-DSA was rated very good in 80% of cases for the detection of perfusion disturbances and vessel anatomy. Conclusions: In comparison to standard CT, contrast-enhanced perfusion CT improves CTs’ diagnostic capability in the emergency examination of children with a strong suspicion of ischemic cerebral infarction.

  15. Accuracy and feasibility of dynamic contrast-enhanced 3D MR imaging in the assessment of lung perfusion: comparison with Tc-99 MAA perfusion scintigraphy

    International Nuclear Information System (INIS)

    Yilmaz, E.; Akkoclu, A.; Degirmenci, B.; Cooper, R.A.; Sengun, B.; Gulcu, A.; Osma, E.; Ucan, E.S.

    2005-01-01

    AIM: The aim of this study was to correlate findings of perfusion magnetic resonance imaging (MRI) and perfusion scintigraphy in cases where there was a suspicion of abnormal pulmonary vasculature, and to evaluate the usefulness of MRI in the detection of perfusion deficits of the lung. METHODS: In all, 17 patients with suspected abnormality of the pulmonary vasculature underwent dynamic contrast-enhanced MRI. T1-weighted 3D fast-field echo pulse sequences were obtained (TR/TE 3.3/1.58 ms; flip angle 30 deg ; slice thickness 12 to 15 mm). The dynamic study was acquired in the coronal plane following administration of 0.1 mmol/kg gadopentetate dimeglumine. A total of 8 to 10 sections repeated 20 to 25 times at intervals of 1 s were performed. Perfusion lung scintigraphy was carried out a maximum of 48 h before the MR examination in all cases. Two radiologists, who were blinded to the clinical data and results of other imaging methods, reviewed all coronal sections. MR perfusion images were independently assessed in terms of segmental or lobar perfusion defects in the 85 lobes of the 17 individuals, and the findings were compared with the results of scintigraphy. RESULTS: Of the 17 patients, 8 were found to have pulmonary emboli, 2 chronic obstructive pulmonary disease with emphysema, 2 bullous emphysema, 2 Takayasu arteritis and 1 had a hypoplastic pulmonary artery. Pulmonary perfusion was completely normal in 2 cases. In 35 lobes, perfusion defects were detected using both methods, in 4 with MR alone and in 9 only with scintigraphy. There was good agreement between MRI and scintigraphy findings (kappa=0.695). CONCLUSION: Pulmonary perfusion MRI is a new alternative to scintigraphy in the evaluation of pulmonary perfusion for various lung disorders. In addition, this technique allows measurement and quantification of pulmonary perfusion abnormalities

  16. Effect of mobilization of bone marrow stem cells by granulocyte colony stimulating factor on clinical symptoms, left ventricular perfusion and function in patients with severe chronic ischemic heart disease

    DEFF Research Database (Denmark)

    Wang, Yongzhong; Tägil, Kristina; Ripa, Rasmus S.

    2005-01-01

    . Myocardial perfusion was unchanged at adenosine stress single photon emission computerized tomography (SPECT) or magnetic resonance images (MRI). Left ventricular ejection fraction decreased from 57% to 52% (p... with echocardiography. CONCLUSIONS: Treatment by G-CSF improved symptoms but not signs of myocardial ischemia in patients with severe IHD. The effects seemed related to mobilization of stem cells. An adverse effect on ejection fraction could not be excluded...

  17. Myocardial perfusion magnetic resonance imaging using sliding-window conjugate-gradient HYPR methods in canine with stenotic coronary arteries.

    Science.gov (United States)

    Ge, Lan; Kino, Aya; Lee, Daniel; Dharmakumar, Rohan; Carr, James C; Li, Debiao

    2010-01-01

    First-pass perfusion magnetic resonance imaging (MRI) is a promising technique for detecting ischemic heart disease. However, the diagnostic value of the method is limited by the low spatial coverage, resolution, signal-to-noise ratio (SNR), and cardiac motion-related image artifacts. A combination of sliding window and conjugate-gradient HighlY constrained back-PRojection reconstruction (SW-CG-HYPR) method has been proposed in healthy volunteer studies to reduce the acquisition window for each slice while maintaining the temporal resolution of 1 frame per heartbeat in myocardial perfusion MRI. This method allows for improved spatial coverage, resolution, and SNR. In this study, we use a controlled animal model to test whether the myocardial territory supplied by a stenotic coronary artery can be detected accurately by SW-CG-HYPR perfusion method under pharmacological stress. Results from 6 mongrel dogs (15-25 kg) studies demonstrate the feasibility of SW-CG-HYPR to detect regional perfusion defects. Using this method, the acquisition time per cardiac cycle was reduced by a factor of 4, and the spatial coverage was increased from 2 to 3 slices to 6 slices as compared with the conventional techniques including both turbo-Fast Low Angle Short (FLASH) and echoplanar imaging (EPI). The SNR of the healthy myocardium at peak enhancement with SW-CG-HYPR (12.68 ± 2.46) is significantly higher (P < 0.01) than the turbo-FLASH (8.65 ± 1.93) and EPI (5.48 ± 1.24). The spatial resolution of SW-CG-HYPR images is 1.2 × 1.2 × 8.0 mm, which is better than the turbo-FLASH (1.8 × 1.8 × 8.0 mm) and EPI (2.0 × 1.8 × 8.0 mm). Sliding-window CG-HYPR is a promising technique for myocardial perfusion MRI. This technique provides higher image quality with respect to significantly improved SNR and spatial resolution of the myocardial perfusion images, which might improve myocardial perfusion imaging in a clinical setting.

  18. Pulmonary MR angiography and perfusion imaging—A review of methods and applications

    Energy Technology Data Exchange (ETDEWEB)

    Johns, Christopher S.; Swift, Andrew J.; Hughes, Paul J.C. [University of Sheffield (United Kingdom); Ohno, Yoshiharu [Division of Functional and Diagnostic Imaging Research, Department of Radiology, KobeUniversity Graduate School of Medicine, Kobe, Hyogo (Japan); Schiebler, Mark [UW-Madison School of Medicine and Public Health, Madison, WI (United States); Wild, Jim M., E-mail: j.m.wild@sheffield.ac.uk [University of Sheffield (United Kingdom)

    2017-01-15

    Highlights: • This article represents an overview of the methodology and clinical applications of pulmonary MRA and perfusion imaging. • Both contrast enhanced and non-contrast enhanced metholodology for MRA and perfusion are covered. • The current clinical uses and future directions of MRA and MR perfusion are discussed. - Abstract: The pulmonary vasculature and its role in perfusion and gas exchange is an important consideration in many conditions of the lung and heart. Currently the mainstay of imaging of the vasculature and perfusion of the lungs lies with CT and nuclear medicine perfusion scans, both of which require ionizing radiation exposure. Improvements in MRI techniques have increased the use of MRI in pulmonary vascular imaging. Here we review MRI methods for imaging the pulmonary vasculature and pulmonary perfusion, both using contrast enhanced and non-contrast enhanced methodology. In many centres pulmonary MR angiography and dynamic contrast enhanced perfusion MRI are now well established in the routine workflow of patients particularly with pulmonary hypertension and thromboembolic disease. However, these imaging modalities offer exciting new directions for future research and clinical use in other respiratory diseases where consideration of pulmonary perfusion and gas exchange can provide insight in to pathophysiology.

  19. Pulmonary MR angiography and perfusion imaging—A review of methods and applications

    International Nuclear Information System (INIS)

    Johns, Christopher S.; Swift, Andrew J.; Hughes, Paul J.C.; Ohno, Yoshiharu; Schiebler, Mark; Wild, Jim M.

    2017-01-01

    Highlights: • This article represents an overview of the methodology and clinical applications of pulmonary MRA and perfusion imaging. • Both contrast enhanced and non-contrast enhanced metholodology for MRA and perfusion are covered. • The current clinical uses and future directions of MRA and MR perfusion are discussed. - Abstract: The pulmonary vasculature and its role in perfusion and gas exchange is an important consideration in many conditions of the lung and heart. Currently the mainstay of imaging of the vasculature and perfusion of the lungs lies with CT and nuclear medicine perfusion scans, both of which require ionizing radiation exposure. Improvements in MRI techniques have increased the use of MRI in pulmonary vascular imaging. Here we review MRI methods for imaging the pulmonary vasculature and pulmonary perfusion, both using contrast enhanced and non-contrast enhanced methodology. In many centres pulmonary MR angiography and dynamic contrast enhanced perfusion MRI are now well established in the routine workflow of patients particularly with pulmonary hypertension and thromboembolic disease. However, these imaging modalities offer exciting new directions for future research and clinical use in other respiratory diseases where consideration of pulmonary perfusion and gas exchange can provide insight in to pathophysiology.

  20. Stress and reward processing in bipolar disorder: an fMRI study

    Science.gov (United States)

    Berghorst, Lisa H; Kumar, Poornima; Greve, Doug N; Deckersbach, Thilo; Ongur, Dost; Dutra, Sunny; Pizzagalli, Diego A

    2016-01-01

    Objectives A link between negative life stress and the onset of mood episodes in bipolar disorder (BD) has been established, but processes underlying such a link remain unclear. Growing evidence suggests that stress can negatively affect reward processing and related neurobiological substrates, indicating that a dysregulated reward system may provide a partial explanation. The aim of this study was to test the impact of stress on reward-related neural functioning in BD. Methods Thirteen euthymic or mildly depressed individuals with BD and 15 controls performed a Monetary Incentive Delay task while undergoing functional magnetic resonance imaging during no-stress and stress (negative psychosocial stressor involving poor performance feedback and threat of monetary deductions) conditions. Results In hypothesis-driven region-of- interest-based analyses, a significant group by condition interaction emerged in the amygdala during reward anticipation. Relative to controls, while anticipating a potential reward, subjects with BD were characterized by amygdalar hyperactivation in the no-stress condition but hypoactivation during stress. Moreover, relative to controls, subjects with BD had significantly larger amygdala volumes. After controlling for structural differences, the effects of stress on amygdalar function remained, whereas groups no longer differed during the no-stress condition. During reward consumption, a group by condition interaction emerged in the putamen due to increased putamen activation to rewards in participants with BD during stress, but an opposite pattern in controls. Conclusions Overall, findings highlight possible impairments in using reward-predicting cues to adaptively engage in goal-directed actions in BD, combined with stress-induced hypersensitivity to reward consumption. Potential clinical implications are discussed. PMID:27870507

  1. Assessment of femoral head perfusion by dynamic MR imaging

    International Nuclear Information System (INIS)

    Ochi, Ryuya; Nakano, Tetsuo; Miyazono, Kazuki; Tsurugami, Hiroshi; Fukuda, Tomohiro; Inaba, Daisuke; Takada, Koji

    2004-01-01

    We studied femoral head perfusion in 21 femoral neck fractures using dynamic MR imaging (MRI) between November 2001 and July 2002. MRI patterns divided into four groups when the results between the fractured side and unaffected side were compared. Femoral head perfusion at the fractured side was normal in Type A, about half in Type B, and absent in Type C. When perfusion at both the fractured side and unaffected side was absent, Exceptional Type was suspected. The Garden I group consisted of one Type B. The Garden II group consisted of one Type A, six Type B, one Type C, and two Exceptional Type. The Garden III group consisted of two Type B and one Type C, and the Garden IV group consisted of six Type C and one Exceptional Type. Post operations of by internal fixation confirmed the incidence of aseptic necrosis using MRI. (author)

  2. Hyperventilation, cerebral perfusion, and syncope

    DEFF Research Database (Denmark)

    Immink, R V; Pott, F C; Secher, N H

    2014-01-01

    dioxide (PaCO2) and oxygen (PaO2) partial pressures so that hypercapnia/hypoxia increases and hypocapnia/hyperoxia reduces global cerebral blood flow. Cerebral hypoperfusion and TLOC have been associated with hypocapnia related to HV. Notwithstanding pronounced cerebrovascular effects of PaCO2...... the contribution of a low PaCO2 to the early postural reduction in middle cerebral artery blood velocity is transient. HV together with postural stress does not reduce cerebral perfusion to such an extent that TLOC develops. However when HV is combined with cardiovascular stressors like cold immersion or reduced...... cardiac output brain perfusion becomes jeopardized. Whether, in patients with cardiovascular disease and/or defect, cerebral blood flow cerebral control HV-induced hypocapnia elicits cerebral hypoperfusion, leading to TLOC, remains to be established....

  3. Perfusion-weighted MR imaging in persistent hemiplegic migraine

    International Nuclear Information System (INIS)

    Mourand, Isabelle; Menjot de Champfleur, Nicolas; Carra-Dalliere, Clarisse; Le Bars, Emmanuelle; Bonafe, Alain; Thouvenot, Eric; Roubertie, Agathe

    2012-01-01

    Hemiplegic migraine is a rare type of migraine that has an aura characterized by the presence of motor weakness, which may occasionally last up to several days, and then resolve without sequela. Pathogenesis of migraine remains unclear and, recently, perfusion-weighted imaging (PWI) has provided a non-invasive method to study hemodynamic changes during acute attacks. Two female patients were admitted in our hospital suffering from prolonged hemiparesis. In both cases, they underwent MRI examination using a 1.5 T magnet including axial diffusion-weighted and perfusion sequences. From each perfusion MRI acquisition two regions of interest were delineated on each hemisphere and, the index of flow, cerebral blood volume, mean transit time, and time to peak were recorded and asymmetry indices from each perfusion parameter were calculated. Perfusion alterations were detected during the attacks. In one case, we observed, after 3 h of left hemiparesia, hypoperfusion of the right hemisphere. In the other case, who presented a familial hemiplegic migraine attack, on the third day of a persistent aura consisting of right hemiplegia and aphasia, PWI revealed hyperperfusion of the left hemisphere. Asymmetry indices for temporal parameters (mean transit time and time to peak) were the most sensitive. These findings resolved spontaneously after the attacks without any permanent sequel or signs of cerebral ischemia on follow-up MRI. PWI should be indicated for patients with migraine attacks accompanied by auras to assess the sequential changes in cerebral perfusion and to better understand its pathogenesis. (orig.)

  4. Perfusion-weighted MR imaging in persistent hemiplegic migraine

    Energy Technology Data Exchange (ETDEWEB)

    Mourand, Isabelle; Menjot de Champfleur, Nicolas; Carra-Dalliere, Clarisse; Le Bars, Emmanuelle; Bonafe, Alain; Thouvenot, Eric [Hopital Gui de Chauliac, Service de Neuroradiologie, Montpellier (France); Roubertie, Agathe [Hopital Gui de Chauliac, Service de Neuropediatrie, Montpellier (France)

    2012-03-15

    Hemiplegic migraine is a rare type of migraine that has an aura characterized by the presence of motor weakness, which may occasionally last up to several days, and then resolve without sequela. Pathogenesis of migraine remains unclear and, recently, perfusion-weighted imaging (PWI) has provided a non-invasive method to study hemodynamic changes during acute attacks. Two female patients were admitted in our hospital suffering from prolonged hemiparesis. In both cases, they underwent MRI examination using a 1.5 T magnet including axial diffusion-weighted and perfusion sequences. From each perfusion MRI acquisition two regions of interest were delineated on each hemisphere and, the index of flow, cerebral blood volume, mean transit time, and time to peak were recorded and asymmetry indices from each perfusion parameter were calculated. Perfusion alterations were detected during the attacks. In one case, we observed, after 3 h of left hemiparesia, hypoperfusion of the right hemisphere. In the other case, who presented a familial hemiplegic migraine attack, on the third day of a persistent aura consisting of right hemiplegia and aphasia, PWI revealed hyperperfusion of the left hemisphere. Asymmetry indices for temporal parameters (mean transit time and time to peak) were the most sensitive. These findings resolved spontaneously after the attacks without any permanent sequel or signs of cerebral ischemia on follow-up MRI. PWI should be indicated for patients with migraine attacks accompanied by auras to assess the sequential changes in cerebral perfusion and to better understand its pathogenesis. (orig.)

  5. Gray matter perfusion correlates with disease severity in ALS.

    Science.gov (United States)

    Rule, Randall R; Schuff, Norbert; Miller, Robert G; Weiner, Michael W

    2010-03-09

    The goal of this study is to determine if regional brain perfusion, as measured by arterial spin labeling (ASL) MRI, is correlated with clinical measures of amyotrophic lateral sclerosis (ALS) disease severity. The presence of such a relationship would indicate a possible role for ASL perfusion as a marker of disease severity and upper motor neuron involvement in ALS. Disease severity was assessed in 16 subjects with ALS (age 54 +/- 11) using the Amyotrophic Lateral Sclerosis Functional Rating Scale (ALSFRS) and the pulmonary function measure, forced vital capacity (FVC). Upper motor neuron involvement was assessed by testing rapid tapping of the fingers and feet. Magnetic resonance perfusion images were coregistered with structural T1-weighted MRI, corrected for partial volume effects using the structural images and normalized to a study-specific atlas. Correlations between perfusion and ALS disease severity were analyzed, using statistical parametric mapping, and including age as a factor. Analyses were adjusted for multiple clusters. ALS severity, as measured by the ALSFRS and FVC, was correlated with gray matter perfusion. This correlation was predominantly observed in the hemisphere contralateral to the more affected limbs. ALSFRS scores correlated with perfusion in the contralateral frontal and parietal lobe (p frontal lobe (p frontal lobe (p Upper motor neuron involvement, as measured by rapid finger tapping, correlated bilaterally with perfusion in the middle cingulate gyrus (p < 0.001). Amyotrophic lateral sclerosis (ALS) severity is correlated with brain perfusion as measured by arterial spin labeling (ASL) perfusion. This correlation appears to be independent of brain atrophy. ASL perfusion may be a useful tool for monitoring disease progression and assessing treatment effects in ALS.

  6. Associations between muscle perfusion and symptoms in knee osteoarthritis

    DEFF Research Database (Denmark)

    Bandak, E; Boesen, M; Bliddal, H

    2015-01-01

    -MRI and clinical data were analyzed in 94 patients. The typical participant was a woman with a mean age of 65 years, and a body mass index (BMI) of 32 kg/m(2). Reduced multiple regression models analyzing the association between KOOS and DCE-MRI perfusion variables of Total Muscle Volume showed a statistically...... significant association between Nvoxel% and KOOS pain (0.41 (SE 0.14); P = 0.0048). Nvoxel% was defined as the proportion of highly perfused voxels; i.e., the voxels that show an early and rapid increase on the signal intensity vs time curves, reach a plateau state (plateau pattern) and then showing...

  7. Adductor insertion avulsion syndrome with stress fracture of femoral shaft: MRI findings

    International Nuclear Information System (INIS)

    Lawande, M.A.; Sankhe, S.; Pungavkar, S.A.; Patkar, D.P.

    2007-01-01

    Full text: Chronic vague hip pain may be caused by stress-related injury in the proximal or mid-femoral diaphysis. This has been described as an entity called adductor insertion avulsion syndrome, or thigh splints. In the appropriate clinical setting, the radiologist interpreting the magnetic resonance imaging must be aware of this condition as its imaging findings are subtle. The diagnosis will help the clinician plan the appropriate management. Magnetic resonance imaging can also depict the complications such as stress fracture

  8. Heart MRI

    Science.gov (United States)

    Magnetic resonance imaging - cardiac; Magnetic resonance imaging - heart; Nuclear magnetic resonance - cardiac; NMR - cardiac; MRI of the heart; Cardiomyopathy - MRI; Heart failure - MRI; Congenital heart disease - MRI

  9. Dynamic MRI confirms support of the mid-urethra by TVT and TVT-O surgery for stress incontinence.

    Science.gov (United States)

    Rinne, Kirsi; Kainulainen, Sakari; Aukee, Sinikka; Heinonen, Seppo; Nilsson, Carl G

    2011-06-01

    To study changes in mid-urethral function with dynamic MRI in stress urinary incontinent women undergoing either tension-free vaginal tape (TVT) or TVT-obturator sling operations. Prospective clinical study. University hospital. Forty-two parous women with stress urinary incontinence recruited to dynamic magnetic resonance imaging before and after mid-urethral sling surgery. Control group of 16 healthy women. Dynamic magnetic resonance imaging at rest, during pelvic floor muscle contraction, coughing and voiding with a bladder volume of 200-300 ml. X- and Y- coordinates were used to determine the location of the mid-urethra during these activities. Changes in mid-urethral position after TVT and TVT-obturator operations during the different activities. Postoperatively the women could elevate their mid-urethra by pelvic floor muscle contraction significantly higher than before the operation (pTVT and the TVT-O mid-urethral slings, we could not see any differences in the movement patterns. Mid-urethral slings support the mid-urethra and restrict downward movement during different activities. Movement patterns are similar after TVT and TVT-O operations. © 2011 The Authors Acta Obstetricia et Gynecologica Scandinavica© 2011 Nordic Federation of Societies of Obstetrics and Gynecology.

  10. Posterior and prefrontal contributions to the development posttraumatic stress disorder symptom severity: an fMRI study of symptom provocation in acute stress disorder.

    Science.gov (United States)

    Cwik, Jan C; Sartory, Gudrun; Nuyken, Malte; Schürholt, Benjamin; Seitz, Rüdiger J

    2017-09-01

    Acute stress disorder (ASD) is predictive of the development of posttraumatic stress disorder (PTSD). In response to symptom provocation, the exposure to trauma-related pictures, ASD patients showed increased activation of the medial posterior areas of precuneus and posterior cingulate cortex as well as of superior prefrontal cortex in a previous study. The current study aimed at investigating which activated areas are predictive of the development of PTSD. Nineteen ASD patients took part in an fMRI study in which they were shown personalized trauma-related and neutral pictures within 4 weeks of the traumatic event. They were assessed for severity of PTSD 4 weeks later. Activation contrasts between trauma-related and neutral pictures were correlated with subsequent PTSD symptom severity. Greater activation in, among others, right medial precuneus, left retrosplenial cortex, precentral and right superior temporal gyrus as well as less activation in lateral, superior prefrontal and left fusiform gyrus was related to subsequently increased PTSD severity. The results are broadly in line with neural areas related to etiological models of PTSD, namely multisensory associative learning recruiting posterior regions on the one hand and failure to reappraise maladaptive cognitions, thought to involve prefrontal areas, on the other.

  11. Evaluation of ocular acupuncture on cerebral infarction with cerebral blood flow perfusion imaging

    International Nuclear Information System (INIS)

    Li Yuge; Gao Qinyi; Wang Shuang; Zhao Yong

    2008-01-01

    To evaluate the immediate effect of ocular acupuncture on patients, an method of SPECT image of cerebral blood flow daily stress test was established. 10 patients diagnosed as cerebral infarction by CT or MRI were tested. They all received 99 Tc m -ECD SPECT imaging at twice before and after ocular acupuncture. By means of image subtraction technique and semi-quantitative method of regional interesting area, the change of regional cerebral blood flow was observed between the two images. Under restful state perfusion of cerebral blood flow in 18 foci was low at the frontal lobe, the cerebellum, the basal ganglia and temporal lobe. After ocular acupuncture, the perfusions were obviously increased in 16 foci among them and the reactivity of the frontal lobe and the cerebellum to ocular acupuncture was higher, the average improvement rate of which was 55.15% and 53.06% respectively, lower in the basal ganglia and temporal lobe, the average improvement rate was 31.79% and 36.67% respectively. 99 Tc m -ECD SPECT cerebral perfusion image has some significant clinic value for evaluating the effect of ocular acupuncture to treating cerebral infarction. (authors)

  12. Dynamic subcortical blood flow during male sexual activity with ecological validity : A perfusion NRI study

    NARCIS (Netherlands)

    Georgiadis, Janniko R.; Farrell, Michael J.; Boessen, Ruud; Denton, Derek A.; Gavrilescu, Maria; Kortekaas, Rudie; Renken, Remco J.; Hoogduin, Johannes M.; Egan, Gary F.

    This study used arterial spin labeling (ASL) fMRI to measure brain perfusion in a group of healthy men under conditions that closely resembled customary sexual behavior. Serial perfusion measures for 30 min during two self-limited periods of partnered penis stimulation, and during post-stimulatory

  13. Measurement of coronary flow response to cold pressor stress in asymptomatic women with cardiovascular risk factors using spiral velocity-encoded cine MRI at 3 Tesla

    International Nuclear Information System (INIS)

    Maroules, Christopher D.; Peshock, Ronald M.; Chang, Alice Y.; Kontak, Andrew; Dimitrov, Ivan; Kotys, Melanie

    2010-01-01

    Background: Coronary sinus (CS) flow in response to a provocative stress has been used as a surrogate measure of coronary flow reserve, and velocity-encoded cine (VEC) magnetic resonance imaging (MRI) is an established technique for measuring CS flow. In this study, the cold pressor test (CPT) was used to measure CS flow response because it elicits an endothelium-dependent coronary vasodilation that may afford greater sensitivity for detecting early changes in coronary endothelial function. Purpose: To investigate the feasibility and reproducibility of CS flow reactivity (CSFR) to CPT using spiral VEC MRI at 3 Tesla in a sample of asymptomatic women with cardiovascular risk factors. Material and Methods: Fourteen asymptomatic women (age 38 years ± 10) with cardiovascular risk factors were studied using 3D spiral VEC MRI of the CS at 3 T. The CPT was utilized as a provocative stress to measure changes in CS flow. CSFR to CPT was calculated from the ratio of CS flow during peak stress to baseline CS flow. Results: CPT induced a significant hemodynamic response as measured by a 45% increase in rate-pressure product (P<0.01). A significant increase in CS volume flow was also observed (baseline, 116 ± 26 ml/min; peak stress, 152 ± 34 ml/min, P=0.01). CSFR to CPT was 1.31 ± 0.20. Test-retest variability of CS volume flow was 5% at baseline and 6% during peak stress. Conclusion: Spiral CS VEC MRI at 3 T is a feasible and reproducible technique for measuring CS flow in asymptomatic women at risk for cardiovascular disease. Significant changes in CSFR to CPT are detectable, without demanding pharmacologic stress

  14. Hypertension impairs myocardial blood perfusion reserve in subjects without regional myocardial ischemia

    International Nuclear Information System (INIS)

    Nakajima, Hiroshi; Onishi, Katsuya; Kurita, Tairo

    2010-01-01

    Quantitative analysis of myocardial perfusion MRI can provide noninvasive assessments of myocardial perfusion reserve (MPR), which is associated with endothelial function. Endothelial function is influenced by various factors, including hypertension, diabetes, dyslipidemia, renal dysfunction and anemia. The purpose of this study was to evaluate which risk factor is the strongest effector of MPR in subjects without regional myocardial ischemia. We studied 110 patients (66 years ±10, male 68%, hypertension 76%, diabetes mellitus (DM) 40% and dyslipidemia 65%) without regional myocardial ischemia. Adenosine triphosphate (ATP) stress and rest first-pass perfusion magnetic resonance (MR) images were acquired with a 1.5-T MR system, and MPR was calculated as the ratio of stress to rest myocardial blood flow (MBF). Average rest MBF in 110 patients was 1.07±0.62 ml min -1 g -1 , whereas stress MBF was 3.15±1.93 ml min -1 g -1 and the MPR was 3.33±1.82. Rest MBF correlated significantly with hematocrit, whereas stress MBF showed a strong correlation with estimated glomerular filtration rate (e-GFR). MPR was associated with hypertension, age, e-GFR, hematocrit and left ventricular mass index (LVMI). In multiple regression analysis, hypertension (P=0.003, β=-0.274) showed the strongest correlation with MPR among other risk factors, such as diabetes (P=ns), dyslipidemia (P=ns), e-GFR (P=ns), LVMI (P=0.007, β=-0.248) and hematocrit (P=ns) after adjusting age and gender. Hypertension is the most important effector of MPR in subjects without myocardial ischemia. (author)

  15. Hypertension impairs myocardial blood perfusion reserve in subjects without regional myocardial ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Hiroshi; Onishi, Katsuya; Kurita, Tairo [Mie Univ., Graduate School of Medicine, Tsu, Mie (Japan)

    2010-11-15

    Quantitative analysis of myocardial perfusion MRI can provide noninvasive assessments of myocardial perfusion reserve (MPR), which is associated with endothelial function. Endothelial function is influenced by various factors, including hypertension, diabetes, dyslipidemia, renal dysfunction and anemia. The purpose of this study was to evaluate which risk factor is the strongest effector of MPR in subjects without regional myocardial ischemia. We studied 110 patients (66 years {+-}10, male 68%, hypertension 76%, diabetes mellitus (DM) 40% and dyslipidemia 65%) without regional myocardial ischemia. Adenosine triphosphate (ATP) stress and rest first-pass perfusion magnetic resonance (MR) images were acquired with a 1.5-T MR system, and MPR was calculated as the ratio of stress to rest myocardial blood flow (MBF). Average rest MBF in 110 patients was 1.07{+-}0.62 ml min{sup -1} g{sup -1}, whereas stress MBF was 3.15{+-}1.93 ml min{sup -1} g{sup -1} and the MPR was 3.33{+-}1.82. Rest MBF correlated significantly with hematocrit, whereas stress MBF showed a strong correlation with estimated glomerular filtration rate (e-GFR). MPR was associated with hypertension, age, e-GFR, hematocrit and left ventricular mass index (LVMI). In multiple regression analysis, hypertension (P=0.003, {beta}=-0.274) showed the strongest correlation with MPR among other risk factors, such as diabetes (P=ns), dyslipidemia (P=ns), e-GFR (P=ns), LVMI (P=0.007, {beta}=-0.248) and hematocrit (P=ns) after adjusting age and gender. Hypertension is the most important effector of MPR in subjects without myocardial ischemia. (author)

  16. Importance of initial stress for abdominal aortic aneurysm wall motion: Dynamic MRI validated finite element analysis

    NARCIS (Netherlands)

    Merkx, M.A.G.; Veer, van 't M.; Speelman, L.; Breeuwer, M.; Buth, J.; Vosse, van de F.N.

    2009-01-01

    Currently the transverse diameter is the primary decision criterion to assess rupture risk in patients with an abdominal aortic aneurysm (AAA). To obtain a measure for more patient-specific risk assessment, aneurysm wall stress, calculated using finite element analysis (FEA), has been evaluated in

  17. Prediction of Liver Function by Using Magnetic Resonance-based Portal Venous Perfusion Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cao Yue, E-mail: yuecao@umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Wang Hesheng [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Johnson, Timothy D. [Department of Biostatistics, University of Michigan, Ann Arbor, Michigan (United States); Pan, Charlie [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Hussain, Hero [Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Balter, James M.; Normolle, Daniel; Ben-Josef, Edgar; Ten Haken, Randall K.; Lawrence, Theodore S.; Feng, Mary [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2013-01-01

    Purpose: To evaluate whether liver function can be assessed globally and spatially by using volumetric dynamic contrast-enhanced magnetic resonance imaging MRI (DCE-MRI) to potentially aid in adaptive treatment planning. Methods and Materials: Seventeen patients with intrahepatic cancer undergoing focal radiation therapy (RT) were enrolled in institution review board-approved prospective studies to obtain DCE-MRI (to measure regional perfusion) and indocyanine green (ICG) clearance rates (to measure overall liver function) prior to, during, and at 1 and 2 months after treatment. The volumetric distribution of portal venous perfusion in the whole liver was estimated for each scan. We assessed the correlation between mean portal venous perfusion in the nontumor volume of the liver and overall liver function measured by ICG before, during, and after RT. The dose response for regional portal venous perfusion to RT was determined using a linear mixed effects model. Results: There was a significant correlation between the ICG clearance rate and mean portal venous perfusion in the functioning liver parenchyma, suggesting that portal venous perfusion could be used as a surrogate for function. Reduction in regional venous perfusion 1 month after RT was predicted by the locally accumulated biologically corrected dose at the end of RT (P<.0007). Regional portal venous perfusion measured during RT was a significant predictor for regional venous perfusion assessed 1 month after RT (P<.00001). Global hypovenous perfusion pre-RT was observed in 4 patients (3 patients with hepatocellular carcinoma and cirrhosis), 3 of whom had recovered from hypoperfusion, except in the highest dose regions, post-RT. In addition, 3 patients who had normal perfusion pre-RT had marked hypervenous perfusion or reperfusion in low-dose regions post-RT. Conclusions: This study suggests that MR-based volumetric hepatic perfusion imaging may be a biomarker for spatial distribution of liver function, which

  18. Laser doppler perfusion imaging

    International Nuclear Information System (INIS)

    Waardell, K.

    1992-01-01

    Recording of tissue perfusion is important in assessing the influence of peripheral vascular diseases on the microcirculation. This thesis reports on a laser doppler perfusion imager based on dynamic light scattering in tissue. When a low power He-Ne laser beam sequentally scans the tissue, moving blood cells generate doppler components in the back-scattered light. A fraction of this light is detected by a photodetector and converted into an electrical signal. In the processor, a signal proportional to the tissue perfusion at each measurement site is calculated and stored. When the scanning procedure is completed, a color-coded perfusion image is presented on a monitor. To convert important aspects of the perfusion image into more quantitative parameters, data analysis functions are implemented in the software. A theory describing the dependence of the distance between individual measurement points and detector on the system amplification factor is proposed and correction algorithms are presented. The performance of the laser doppler perfusion imager was evaluated using a flow simulator. A linear relationship between processor output signal and flow through the simulator was demonstrated for blood cell concentrations below 0.2%. The median sampling depth of the laser beam was simulated by a Monte Carlo technique and estimated to 235 μm. The perfusion imager has been used in the clinic to study perfusion changes in port wine stains treated with argon laser and to investigate the intensity and extension of the cutaneous axon reflex response after electrical nerve stimulation. The fact that perfusion can be visualized without touching the tissue implies elimination of sterilization problems, thus simplifying clinical investigations of perfusion in association with diagnosis and treatment of peripheral vascular diseases. 22 refs

  19. A computer-simulation study on the effects of MRI voxel dimensions on carotid plaque lipid-core and fibrous cap segmentation and stress modeling.

    Directory of Open Access Journals (Sweden)

    Harm A Nieuwstadt

    Full Text Available The benefits of a decreased slice thickness and/or in-plane voxel size in carotid MRI for atherosclerotic plaque component quantification accuracy and biomechanical peak cap stress analysis have not yet been investigated in detail because of practical limitations.In order to provide a methodology that allows such an investigation in detail, numerical simulations of a T1-weighted, contrast-enhanced, 2D MRI sequence were employed. Both the slice thickness (2 mm, 1 mm, and 0.5 mm and the in plane acquired voxel size (0.62x0.62 mm2 and 0.31x0.31 mm2 were varied. This virtual MRI approach was applied to 8 histology-based 3D patient carotid atherosclerotic plaque models.A decreased slice thickness did not result in major improvements in lumen, vessel wall, and lipid-rich necrotic core size measurements. At 0.62x0.62 mm2 in-plane, only a 0.5 mm slice thickness resulted in improved minimum fibrous cap thickness measurements (a 2-3 fold reduction in measurement error and only marginally improved peak cap stress computations. Acquiring voxels of 0.31x0.31 mm2 in-plane, however, led to either similar or significantly larger improvements in plaque component quantification and computed peak cap stress.This study provides evidence that for currently-used 2D carotid MRI protocols, a decreased slice thickness might not be more beneficial for plaque measurement accuracy than a decreased in-plane voxel size. The MRI simulations performed indicate that not a reduced slice thickness (i.e. more isotropic imaging, but the acquisition of anisotropic voxels with a relatively smaller in-plane voxel size could improve carotid plaque quantification and computed peak cap stress accuracy.

  20. MR Spectroscopy and Perfusion MR Imaging Findings of Intracranial Foreign Body Granuloma: a Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Seung Won; Kim, Sang Joon; Kim, Sun Mi; Lee, Jeong Hyun; Choi, Choong Gon; Lee, Deok Hee; Lee, Jung Kyo [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Kim, Eun Ju [Philips Healthcare, Seoul (Korea, Republic of)

    2010-06-15

    We report a case of intracranial foreign body granuloma that showed features of a high grade tumor on magnetic resonance (MR) imaging. However, the relative cerebral blood volume was not increased in the enhancing mass on perfusion MRI and the choline/creatine ratio only slightly increased on MR spectroscopy. The results suggest that the lesion is benign in nature. Perfusion MRI and MR spectroscopy may be helpful to differentiate a foreign body granuloma from a neoplastic condition

  1. Dipyridamole stress myocardial perfusion by computed tomography in patients with left bundle branch block; Perfusao miocardica de estresse com dipiridamol por tomografia computadorizada em pacientes com bloqueio de ramo esquerdo

    Energy Technology Data Exchange (ETDEWEB)

    Cabeda, Estevan Vieira; Rochitte, Carlos Eduardo; Nomura, Cesar Higa; Parga, Jose Rodrigues; Avila, Luiz Francisco Rodrigues; Falcao, Andrea Maria Gomes; Soares Junior, Jose [Instituto do Coracao (InCor), Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil)

    2015-12-15

    Background: Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). Objective: To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and compare the results with those of single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy. Methods: Thirty patients with LBBB who had undergone SPECT for the investigation of coronary artery disease were referred for stress tomography. Independent examiners performed per-patient and per-coronary territory assessments. All patients gave written informed consent to participate in the study that was approved by the institution's ethics committee. Results: The patients' mean age was 62 ± 10 years. The mean dose of radiation for the tomography protocol was 9.3 ± 4.6 mSv. With regard to CTP, the per-patient values for sensitivity, specificity, positive and negative predictive values, and accuracy were 86%, 81%, 80%, 87%, and 83%, respectively (p = 0.001). The per-territory values were 63%, 86%, 65%, 84%, and 79%, respectively (p < 0.001). In both analyses, the addition of CTP to CTA achieved higher diagnostic accuracy for detecting myocardial ischemia than SPECT (p < 0.001). Conclusion: The use of the stress tomography protocol is feasible and has good diagnostic accuracy for assessing myocardial ischemia in patients with LBBB. (author)

  2. Differences in pelvic floor morphology between continent, stress urinary incontinent, and mixed urinary incontinent elderly women: An MRI study.

    Science.gov (United States)

    Pontbriand-Drolet, Stéphanie; Tang, An; Madill, Stephanie J; Tannenbaum, Cara; Lemieux, Marie-Claude; Corcos, Jacques; Dumoulin, Chantale

    2016-04-01

    To compare magnetic resonance imaging (MRI) of the pelvic floor musculature (PFM), bladder neck and urethral sphincter morphology under three conditions (rest, PFM maximal voluntary contraction (MVC), and straining) in older women with symptoms of stress (SUI) or mixed urinary incontinence (MUI) or without incontinence. This 2008-2012 exploratory observational cohort study was conducted with community-dwelling women aged 60 and over. Sixty six women (22 per group), mean age of 67.7 ± 5.2 years, participated in the study. A 3 T MRI examination was conducted under three conditions: rest, PFM MVC, and straining. ANOVA or Kruskal-Wallis tests (data not normally distributed) were conducted, with Bonferroni correction, to compare anatomical measurements between groups. Women with MUI symptoms had a lower PFM resting position (M-Line P = 0.010 and PC/H-line angle P = 0.026) and lower pelvic organ support (urethrovesical junction height P = 0.013) than both continent and SUI women. Women with SUI symptoms were more likely to exhibit bladder neck funneling and a larger posterior urethrovesical angle at rest than both continent and MUI women (P = 0.026 and P = 0.008, respectively). There were no significant differences between groups on PFM MVC or straining. Women with SUI and MUI symptoms present different morphological defects at rest. These observations emphasize the need to tailor UI interventions to specific pelvic floor defects and UI type in older women. Older women with UI demonstrate different problems with their pelvic organ support structures depending on the type of UI. These new findings should be taken into consideration for future research into developing new treatment strategies for UI in older women. Neurourol. Urodynam. 35:515-521, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  3. Role of myocardial perfusion single photon emission computed tomography in pediatric cardiology practice

    Directory of Open Access Journals (Sweden)

    Sundaram P

    2009-01-01

    Full Text Available Diagnostic and prognostic power of myocardial perfusion imaging in patients with coronary artery disease has been demonstrated with planar imaging which was further improvised with addition of gated SPECT and newer Technetium labeled myocardial perfusion tracers like SestaMIBI, Tetrofosmin. Myocardial perfusion abnormalities at rest and after stress are considered to be the best predictors of cardiac event-free survival in adults with ischemic heart disease. This article highlights various myocardial perfusion imaging (MPIradiopharmaceuticals, exercise procedures, pharmacological stress protocols, indications for MPI and myocardial perfusion patterns in children with some of the common congenital and acquired heart diseases.