WorldWideScience

Sample records for streak camera observations

  1. Ultra fast x-ray streak camera

    International Nuclear Information System (INIS)

    Coleman, L.W.; McConaghy, C.F.

    1975-01-01

    A unique ultrafast x-ray sensitive streak camera, with a time resolution of 50psec, has been built and operated. A 100A thick gold photocathode on a beryllium vacuum window is used in a modified commerical image converter tube. The X-ray streak camera has been used in experiments to observe time resolved emission from laser-produced plasmas. (author)

  2. X-ray streak camera for observation of tightly pinched relativistic electron beams

    International Nuclear Information System (INIS)

    Johnson, D.J.

    1977-01-01

    A pinhole camera is coupled with a Pilot-B scintillator and image-intensified TRW streak camera to study pinched electron beam profiles via observation of anode target bremsstrahlung. Streak intensification is achieved with an EMI image intensifier operated at a gain of up to 10 6 which allows optimizing the pinhole configuration so that resolution is simultaneously limited by photon-counting statistics and pinhole geometry. The pinhole used is one-dimensional and is fabricated by inserting uranium shims with hyperbolic curved edges between two 5-cm-thick lead blocks. The loss of spatial resolution due to the x-ray transmission through the perimeter of the pinhole is calculated and a streak photograph of a Gamble I pinched beam interacting with a brass anode is presented

  3. Soft x-ray streak cameras

    International Nuclear Information System (INIS)

    Stradling, G.L.

    1988-01-01

    This paper is a discussion of the development and of the current state of the art in picosecond soft x-ray streak camera technology. Accomplishments from a number of institutions are discussed. X-ray streak cameras vary from standard visible streak camera designs in the use of an x-ray transmitting window and an x-ray sensitive photocathode. The spectral sensitivity range of these instruments includes portions of the near UV and extends from the subkilovolt x- ray region to several tens of kilovolts. Attendant challenges encountered in the design and use of x-ray streak cameras include the accommodation of high-voltage and vacuum requirements, as well as manipulation of a photocathode structure which is often fragile. The x-ray transmitting window is generally too fragile to withstand atmospheric pressure, necessitating active vacuum pumping and a vacuum line of sight to the x-ray signal source. Because of the difficulty of manipulating x-ray beams with conventional optics, as is done with visible light, the size of the photocathode sensing area, access to the front of the tube, the ability to insert the streak tube into a vacuum chamber and the capability to trigger the sweep with very short internal delay times are issues uniquely relevant to x-ray streak camera use. The physics of electron imaging may place more stringent limitations on the temporal and spatial resolution obtainable with x-ray photocathodes than with the visible counterpart. Other issues which are common to the entire streak camera community also concern the x-ray streak camera users and manufacturers

  4. Streak camera recording of interferometer fringes

    International Nuclear Information System (INIS)

    Parker, N.L.; Chau, H.H.

    1977-01-01

    The use of an electronic high-speed camera in the streaking mode to record interference fringe motion from a velocity interferometer is discussed. Advantages of this method over the photomultiplier tube-oscilloscope approach are delineated. Performance testing and data for the electronic streak camera are discussed. The velocity profile of a mylar flyer accelerated by an electrically exploded bridge, and the jump-off velocity of metal targets struck by these mylar flyers are measured in the camera tests. Advantages of the streak camera include portability, low cost, ease of operation and maintenance, simplified interferometer optics, and rapid data analysis

  5. Notes on the IMACON 500 streak camera system

    International Nuclear Information System (INIS)

    Clendenin, J.E.

    1985-01-01

    The notes provided are intended to supplement the instruction manual for the IMACON 500 streak camera system. The notes cover the streak analyzer, instructions for timing the streak camera, and calibration

  6. Traveling wave deflector design for femtosecond streak camera

    International Nuclear Information System (INIS)

    Pei, Chengquan; Wu, Shengli; Luo, Duan; Wen, Wenlong; Xu, Junkai; Tian, Jinshou; Zhang, Minrui; Chen, Pin; Chen, Jianzhong; Liu, Rong

    2017-01-01

    In this paper, a traveling wave deflection deflector (TWD) with a slow-wave property induced by a microstrip transmission line is proposed for femtosecond streak cameras. The pass width and dispersion properties were simulated. In addition, the dynamic temporal resolution of the femtosecond camera was simulated by CST software. The results showed that with the proposed TWD a femtosecond streak camera can achieve a dynamic temporal resolution of less than 600 fs. Experiments were done to test the femtosecond streak camera, and an 800 fs dynamic temporal resolution was obtained. Guidance is provided for optimizing a femtosecond streak camera to obtain higher temporal resolution.

  7. Traveling wave deflector design for femtosecond streak camera

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Chengquan; Wu, Shengli [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); Luo, Duan [Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Wen, Wenlong [Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); Xu, Junkai [Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Tian, Jinshou, E-mail: tianjs@opt.ac.cn [Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, Shanxi 030006 (China); Zhang, Minrui; Chen, Pin [Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Chen, Jianzhong [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); Liu, Rong [Xi' an Technological University, Xi' an 710021 (China)

    2017-05-21

    In this paper, a traveling wave deflection deflector (TWD) with a slow-wave property induced by a microstrip transmission line is proposed for femtosecond streak cameras. The pass width and dispersion properties were simulated. In addition, the dynamic temporal resolution of the femtosecond camera was simulated by CST software. The results showed that with the proposed TWD a femtosecond streak camera can achieve a dynamic temporal resolution of less than 600 fs. Experiments were done to test the femtosecond streak camera, and an 800 fs dynamic temporal resolution was obtained. Guidance is provided for optimizing a femtosecond streak camera to obtain higher temporal resolution.

  8. Compact Optical Technique for Streak Camera Calibration

    International Nuclear Information System (INIS)

    Bell, P; Griffith, R; Hagans, K; Lerche, R; Allen, C; Davies, T; Janson, F; Justin, R; Marshall, B; Sweningsen, O

    2004-01-01

    The National Ignition Facility (NIF) is under construction at the Lawrence Livermore National Laboratory (LLNL) for the U.S. Department of Energy Stockpile Stewardship Program. Optical streak cameras are an integral part of the experimental diagnostics instrumentation. To accurately reduce data from the streak cameras a temporal calibration is required. This article describes a technique for generating trains of precisely timed short-duration optical pulses1 (optical comb generators) that are suitable for temporal calibrations. These optical comb generators (Figure 1) are used with the LLNL optical streak cameras. They are small, portable light sources that produce a series of temporally short, uniformly spaced, optical pulses. Comb generators have been produced with 0.1, 0.5, 1, 3, 6, and 10-GHz pulse trains of 780-nm wavelength light with individual pulse durations of ∼25-ps FWHM. Signal output is via a fiber-optic connector. Signal is transported from comb generator to streak camera through multi-mode, graded-index optical fibers. At the NIF, ultra-fast streak-cameras are used by the Laser Fusion Program experimentalists to record fast transient optical signals. Their temporal resolution is unmatched by any other transient recorder. Their ability to spatially discriminate an image along the input slit allows them to function as a one-dimensional image recorder, time-resolved spectrometer, or multichannel transient recorder. Depending on the choice of photocathode, they can be made sensitive to photon energies from 1.1 eV to 30 keV and beyond. Comb generators perform two important functions for LLNL streak-camera users. First, comb generators are used as a precision time-mark generator for calibrating streak camera sweep rates. Accuracy is achieved by averaging many streak camera images of comb generator signals. Time-base calibrations with portable comb generators are easily done in both the calibration laboratory and in situ. Second, comb signals are applied

  9. Flat-field response and geometric distortion measurements of optical streak cameras

    International Nuclear Information System (INIS)

    Montgomery, D.S.; Drake, R.P.; Jones, B.A.; Wiedwald, J.D.

    1987-08-01

    To accurately measure pulse amplitude, shape, and relative time histories of optical signals with an optical streak camera, it is necessary to correct each recorded image for spatially-dependent gain nonuniformity and geometric distortion. Gain nonuniformities arise from sensitivity variations in the streak-tube photocathode, phosphor screen, image-intensifier tube, and image recording system. These nonuniformities may be severe, and have been observed to be on the order of 100% for some LLNL optical streak cameras. Geometric distortion due to optical couplings, electron-optics, and sweep nonlinearity not only affects pulse position and timing measurements, but affects pulse amplitude and shape measurements as well. By using a 1.053-μm, long-pulse, high-power laser to generate a spatially and temporally uniform source as input to the streak camera, the combined effects of flat-field response and geometric distortion can be measured under the normal dynamic operation of cameras with S-1 photocathodes. Additionally, by using the same laser system to generate a train of short pulses that can be spatially modulated at the input of the streak camera, we can effectively create a two-dimensional grid of equally-spaced pulses. This allows a dynamic measurement of the geometric distortion of the streak camera. We will discuss the techniques involved in performing these calibrations, will present some of the measured results for LLNL optical streak cameras, and will discuss software methods to correct for these effects. 6 refs., 6 figs

  10. Characterization of X-ray streak cameras for use on Nova

    International Nuclear Information System (INIS)

    Kalantar, D.H.; Bell, P.M.; Costa, R.L.; Hammel, B.A.; Landen, O.L.; Orzechowski, T.J.; Hares, J.D.; Dymoke-Bradshaw, A.K.L.

    1996-09-01

    There are many different types of measurements that require a continuous time history of x-ray emission that can be provided with an x-ray streak camera. In order to properly analyze the images that are recorded with the x-ray streak cameras operated on Nova, it is important to account for the streak characterization of each camera. We have performed a number of calibrations of the streak cameras both on the bench as well as with Nova disk target shots where we use a time modulated laser intensity profile (self-beating of the laser) on the target to generate an x-ray comb. We have measured the streak camera sweep direction and spatial offset, curvature of the electron optics, sweep rate, and magnification and resolution of the electron optics

  11. Compact Optical Technique for Streak Camera Calibration

    International Nuclear Information System (INIS)

    Curt Allen; Terence Davies; Frans Janson; Ronald Justin; Bruce Marshall; Oliver Sweningsen; Perry Bell; Roger Griffith; Karla Hagans; Richard Lerche

    2004-01-01

    The National Ignition Facility is under construction at the Lawrence Livermore National Laboratory for the U.S. Department of Energy Stockpile Stewardship Program. Optical streak cameras are an integral part of the experimental diagnostics instrumentation. To accurately reduce data from the streak cameras a temporal calibration is required. This article describes a technique for generating trains of precisely timed short-duration optical pulses that are suitable for temporal calibrations

  12. Reliable and repeatable characterization of optical streak cameras

    International Nuclear Information System (INIS)

    Charest, Michael R. Jr.; Torres, Peter III; Silbernagel, Christopher T.; Kalantar, Daniel H.

    2008-01-01

    Optical streak cameras are used as primary diagnostics for a wide range of physics and laser experiments at facilities such as the National Ignition Facility. To meet the strict accuracy requirements needed for these experiments, the systematic nonlinearities of the streak cameras (attributed to nonlinearities in the optical and electrical components that make up the streak camera system) must be characterized. In some cases the characterization information is used as a guide to help determine how experiment data should be taken. In other cases, the characterization data are applied to the raw data images to correct for the nonlinearities. In order to characterize an optical streak camera, a specific set of data is collected, where the response to defined inputs are recorded. A set of analysis software routines has been developed to extract information such as spatial resolution, dynamic range, and temporal resolution from this data set. The routines are highly automated, requiring very little user input and thus provide very reliable and repeatable results that are not subject to interpretation. An emphasis on quality control has been placed on these routines due to the high importance of the camera characterization information.

  13. Reliable and Repeatable Characterization of Optical Streak Cameras

    International Nuclear Information System (INIS)

    Kalantar, D; Charest, M; Torres III, P; Charest, M

    2008-01-01

    Optical streak cameras are used as primary diagnostics for a wide range of physics and laser experiments at facilities such as the National Ignition Facility (NIF). To meet the strict accuracy requirements needed for these experiments, the systematic nonlinearities of the streak cameras (attributed to nonlinearities in the optical and electrical components that make up the streak camera system) must be characterized. In some cases the characterization information is used as a guide to help determine how experiment data should be taken. In other cases, the characterization data are applied to the raw data images to correct for the nonlinearities. In order to characterize an optical streak camera, a specific set of data is collected, where the response to defined inputs are recorded. A set of analysis software routines has been developed to extract information such as spatial resolution, dynamic range, and temporal resolution from this data set. The routines are highly automated, requiring very little user input and thus provide very reliable and repeatable results that are not subject to interpretation. An emphasis on quality control has been placed on these routines due to the high importance of the camera characterization information

  14. Reliable and Repeatable Characterization of Optical Streak Cameras

    Energy Technology Data Exchange (ETDEWEB)

    Michael Charest Jr., Peter Torres III, Christopher Silbernagel, and Daniel Kalantar

    2008-10-31

    Optical streak cameras are used as primary diagnostics for a wide range of physics and laser experiments at facilities such as the National Ignition Facility (NIF). To meet the strict accuracy requirements needed for these experiments, the systematic nonlinearities of the streak cameras (attributed to nonlinearities in the optical and electrical components that make up the streak camera system) must be characterized. In some cases the characterization information is used as a guide to help determine how experiment data should be taken. In other cases, the characterization data are applied to the raw data images to correct for the nonlinearities. In order to characterize an optical streak camera, a specific set of data is collected, where the response to defined inputs are recorded. A set of analysis software routines has been developed to extract information such as spatial resolution, dynamic range, and temporal resolution from this data set. The routines are highly automated, requiring very little user input and thus provide very reliable and repeatable results that are not subject to interpretation. An emphasis on quality control has been placed on these routines due to the high importance of the camera characterization information.

  15. Reliable and Repeatable Characterication of Optical Streak Cameras

    Energy Technology Data Exchange (ETDEWEB)

    Kalantar, D; Charest, M; Torres III, P; Charest, M

    2008-05-06

    Optical streak cameras are used as primary diagnostics for a wide range of physics and laser experiments at facilities such as the National Ignition Facility (NIF). To meet the strict accuracy requirements needed for these experiments, the systematic nonlinearities of the streak cameras (attributed to nonlinearities in the optical and electrical components that make up the streak camera system) must be characterized. In some cases the characterization information is used as a guide to help determine how experiment data should be taken. In other cases, the characterization data are applied to the raw data images to correct for the nonlinearities. In order to characterize an optical streak camera, a specific set of data is collected, where the response to defined inputs are recorded. A set of analysis software routines has been developed to extract information such as spatial resolution, dynamic range, and temporal resolution from this data set. The routines are highly automated, requiring very little user input and thus provide very reliable and repeatable results that are not subject to interpretation. An emphasis on quality control has been placed on these routines due to the high importance of the camera characterization information.

  16. Microprocessor-controlled wide-range streak camera

    Science.gov (United States)

    Lewis, Amy E.; Hollabaugh, Craig

    2006-08-01

    Bechtel Nevada/NSTec recently announced deployment of their fifth generation streak camera. This camera incorporates many advanced features beyond those currently available for streak cameras. The arc-resistant driver includes a trigger lockout mechanism, actively monitors input trigger levels, and incorporates a high-voltage fault interrupter for user safety and tube protection. The camera is completely modular and may deflect over a variable full-sweep time of 15 nanoseconds to 500 microseconds. The camera design is compatible with both large- and small-format commercial tubes from several vendors. The embedded microprocessor offers Ethernet connectivity, and XML [extensible markup language]-based configuration management with non-volatile parameter storage using flash-based storage media. The camera's user interface is platform-independent (Microsoft Windows, Unix, Linux, Macintosh OSX) and is accessible using an AJAX [asynchronous Javascript and XML]-equipped modem browser, such as Internet Explorer 6, Firefox, or Safari. User interface operation requires no installation of client software or browser plug-in technology. Automation software can also access the camera configuration and control using HTTP [hypertext transfer protocol]. The software architecture supports multiple-simultaneous clients, multiple cameras, and multiple module access with a standard browser. The entire user interface can be customized.

  17. Microprocessor-controlled, wide-range streak camera

    International Nuclear Information System (INIS)

    Amy E. Lewis; Craig Hollabaugh

    2006-01-01

    Bechtel Nevada/NSTec recently announced deployment of their fifth generation streak camera. This camera incorporates many advanced features beyond those currently available for streak cameras. The arc-resistant driver includes a trigger lockout mechanism, actively monitors input trigger levels, and incorporates a high-voltage fault interrupter for user safety and tube protection. The camera is completely modular and may deflect over a variable full-sweep time of 15 nanoseconds to 500 microseconds. The camera design is compatible with both large- and small-format commercial tubes from several vendors. The embedded microprocessor offers Ethernet connectivity, and XML [extensible markup language]-based configuration management with non-volatile parameter storage using flash-based storage media. The camera's user interface is platform-independent (Microsoft Windows, Unix, Linux, Macintosh OSX) and is accessible using an AJAX [asynchronous Javascript and XML]-equipped modem browser, such as Internet Explorer 6, Firefox, or Safari. User interface operation requires no installation of client software or browser plug-in technology. Automation software can also access the camera configuration and control using HTTP [hypertext transfer protocol]. The software architecture supports multiple-simultaneous clients, multiple cameras, and multiple module access with a standard browser. The entire user interface can be customized

  18. Triggered streak and framing rotating-mirror cameras

    International Nuclear Information System (INIS)

    Huston, A.E.; Tabrar, A.

    1975-01-01

    A pulse motor has been developed which enables a mirror to be rotated to speeds in excess of 20,000 rpm with 10 -4 s. High-speed cameras of both streak and framing type have been assembled which incorporate this mirror drive, giving streak writing speeds up to 2,000ms -1 , and framing speeds up to 500,000 frames s -1 , in each case with the capability of triggering the camera from the event under investigation. (author)

  19. Soft x-ray streak camera for laser fusion applications

    International Nuclear Information System (INIS)

    Stradling, G.L.

    1981-04-01

    This thesis reviews the development and significance of the soft x-ray streak camera (SXRSC) in the context of inertial confinement fusion energy development. A brief introduction of laser fusion and laser fusion diagnostics is presented. The need for a soft x-ray streak camera as a laser fusion diagnostic is shown. Basic x-ray streak camera characteristics, design, and operation are reviewed. The SXRSC design criteria, the requirement for a subkilovolt x-ray transmitting window, and the resulting camera design are explained. Theory and design of reflector-filter pair combinations for three subkilovolt channels centered at 220 eV, 460 eV, and 620 eV are also presented. Calibration experiments are explained and data showing a dynamic range of 1000 and a sweep speed of 134 psec/mm are presented. Sensitivity modifications to the soft x-ray streak camera for a high-power target shot are described. A preliminary investigation, using a stepped cathode, of the thickness dependence of the gold photocathode response is discussed. Data from a typical Argus laser gold-disk target experiment are shown

  20. Flat-field response and geometric distortion measurements of optical streak cameras

    International Nuclear Information System (INIS)

    Montgomery, D.S.; Drake, R.P.; Jones, B.A.; Wiedwald, J.D.

    1987-01-01

    To accurately measure pulse amplitude, shape, and relative time histories of optical signals with an optical streak camera, it is necessary to correct each recorded image for spatially-dependent gain nonuniformity and geometric distortion. Gain nonuniformities arise from sensitivity variations in the streak-tube photocathode, phosphor screen, image-intensifier tube, and image recording system. By using a 1.053-μm, long-pulse, high-power laser to generate a spatially and temporally uniform source as input to the streak camera, the combined effects of flat-field response and geometric distortion can be measured under the normal dynamic operation of cameras with S-1 photocathodes. Additionally, by using the same laser system to generate a train of short pulses that can be spatially modulated at the input of the streak camera, the authors can create a two-dimensional grid of equally-spaced pulses. This allows a dynamic measurement of the geometric distortion of the streak camera. The author discusses the techniques involved in performing these calibrations, present some of the measured results for LLNL optical streak cameras, and will discuss software methods to correct for these effects

  1. Fabry-Perot interferometry using an image-intensified rotating-mirror streak camera

    International Nuclear Information System (INIS)

    Seitz, W.L.; Stacy, H.L.

    1983-01-01

    A Fabry-Perot velocity interferometer system is described that uses a modified rotating mirror streak camera to recrod the dynamic fringe positions. A Los Alamos Model 72B rotating-mirror streak camera, equipped with a beryllium mirror, was modified to include a high aperture (f/2.5) relay lens and a 40-mm image-intensifier tube such that the image normally formed at the film plane of the streak camera is projected onto the intensifier tube. Fringe records for thin (0.13 mm) flyers driven by a small bridgewire detonator obtained with a Model C1155-01 Hamamatsu and Model 790 Imacon electronic streak cameras are compared with those obtained with the image-intensified rotating-mirror streak camera (I 2 RMC). Resolution comparisons indicate that the I 2 RMC gives better time resolution than either the Hamamatsu or the Imacon for total writing times of a few microseconds or longer

  2. Dynamic range studies of the RCA streak tube in the LLL streak camera

    International Nuclear Information System (INIS)

    Thomas, S.W.; Phillips, G.E.

    1979-01-01

    As indicated by tests on several cameras, the dynamic range of the Lawrence Livermore Laboratory streak-camera system appears to be about two orders of magnitude greater than those reported for other systems for 10- to 200-ps pulses. The lack of a fine mesh grid in the RCA streak tube used in these cameras probably contributes to a lower system dynamic noise and therefore raises the dynamic range. A developmental tube with a mesh grid was tested and supports this conjecture. Order-of-magnitude variations in input slit width do not affect the spot size on the phosphor or the dynamic range of the RCA tube. (author)

  3. Picosecond X-ray streak camera dynamic range measurement

    Energy Technology Data Exchange (ETDEWEB)

    Zuber, C., E-mail: celine.zuber@cea.fr; Bazzoli, S.; Brunel, P.; Gontier, D.; Raimbourg, J.; Rubbelynck, C.; Trosseille, C. [CEA, DAM, DIF, F-91297 Arpajon (France); Fronty, J.-P.; Goulmy, C. [Photonis SAS, Avenue Roger Roncier, BP 520, 19106 Brive Cedex (France)

    2016-09-15

    Streak cameras are widely used to record the spatio-temporal evolution of laser-induced plasma. A prototype of picosecond X-ray streak camera has been developed and tested by Commissariat à l’Énergie Atomique et aux Énergies Alternatives to answer the Laser MegaJoule specific needs. The dynamic range of this instrument is measured with picosecond X-ray pulses generated by the interaction of a laser beam and a copper target. The required value of 100 is reached only in the configurations combining the slowest sweeping speed and optimization of the streak tube electron throughput by an appropriate choice of high voltages applied to its electrodes.

  4. Microprocessor-controlled, wide-range streak camera

    Energy Technology Data Exchange (ETDEWEB)

    Amy E. Lewis, Craig Hollabaugh

    2006-09-01

    Bechtel Nevada/NSTec recently announced deployment of their fifth generation streak camera. This camera incorporates many advanced features beyond those currently available for streak cameras. The arc-resistant driver includes a trigger lockout mechanism, actively monitors input trigger levels, and incorporates a high-voltage fault interrupter for user safety and tube protection. The camera is completely modular and may deflect over a variable full-sweep time of 15 nanoseconds to 500 microseconds. The camera design is compatible with both large- and small-format commercial tubes from several vendors. The embedded microprocessor offers Ethernet connectivity, and XML [extensible markup language]-based configuration management with non-volatile parameter storage using flash-based storage media. The camera’s user interface is platform-independent (Microsoft Windows, Unix, Linux, Macintosh OSX) and is accessible using an AJAX [asynchronous Javascript and XML]-equipped modem browser, such as Internet Explorer 6, Firefox, or Safari. User interface operation requires no installation of client software or browser plug-in technology. Automation software can also access the camera configuration and control using HTTP [hypertext transfer protocol]. The software architecture supports multiple-simultaneous clients, multiple cameras, and multiple module access with a standard browser. The entire user interface can be customized.

  5. Reliable and Repeatable Characterization of Optical Streak Cameras

    International Nuclear Information System (INIS)

    Michael R. Charest, Peter Torres III, Christopher Silbernagel

    2008-01-01

    Optical streak cameras are used as primary diagnostics for a wide range of physics and laser performance verification experiments at the National Ignition Facility (NIF). To meet the strict accuracy requirements needed for these experiments, the systematic nonlinearities of the streak cameras (attributed to nonlinearities in the optical and electronic components that make up the streak camera system) must be characterized. In some cases the characterization information is used as a guide to help determine how experiment data should be taken. In other cases the characterization data is used to 'correct' data images, to remove some of the nonlinearities. In order to obtain these camera characterizations, a specific data set is collected where the response to specific known inputs is recorded. A set of analysis software routines has been developed to extract information such as spatial resolution, dynamic range, temporal resolution, etc., from this data set. The routines are highly automated, requiring very little user input and thus provide very reliable and repeatable results that are not subject to interpretation. An emphasis on quality control has been placed on these routines due to the high importance of the camera characterization information

  6. Sweep devices for picosecond image-converter streak cameras

    International Nuclear Information System (INIS)

    Cunin, B.; Miehe, J.A.; Sipp, B.; Schelev, M.Ya.; Serduchenko, J.N.; Thebault, J.

    1979-01-01

    Four different sweep devices based on microwave tubes, avalanche transistors, krytrons, and laser-triggered spark gaps are treated in detail. These control circuits are developed for picosecond image-converter cameras and generate sweep pulses providing streak speeds in the range of 10 7 to 5x10 10 cm/sec with maximum time resolution better than 10 -12 sec. Special low-jitter triggering schemes reduce the jitter to less than 5x10 -11 sec. Some problems arising in the construction and matching of the sweep devices and image-streak tube are discussed. Comparative parameters of nanosecond switching elements are presented. The results described can be used by other authors involved in streak camera development

  7. Design of neutron streak camera for fusion diagnostics

    International Nuclear Information System (INIS)

    Wang, C.L.; Kalibjian, R.; Singh, M.S.

    1982-06-01

    The D-T burn time for advanced laser-fusion targets is calculated to be very short, 2 . Each fission fragment leaving the cathode generates 400 secondary electrons that are all < 20 eV. These electrons are focussed to a point with an extractor and an anode, and are then purified with an electrostatic deflector. The electron beam is streaked and detected with the standard streak camera techniques. Careful shielding is needed for x-rays from the fusion target and general background. It appears that the neutron streak camera can be a viable and unique tool for studying temporal history of fusion burns in D-T plasmas of a few keV ion temperature

  8. Improvements in Off-Center Focusing in an X-ray Streak Camera

    International Nuclear Information System (INIS)

    McDonald, J W; Weber, F; Holder, J P; Bell, P M

    2003-01-01

    Due to the planar construction of present x-ray streak tubes significant off-center defocusing is observed in both static and dynamic images taken with one-dimensional resolution slits. Based on the streak tube geometry curved photocathodes with radii of curvature ranging from 3.5 to 18 inches have been fabricated. We report initial off-center focusing performance data on the evaluation of these ''improved'' photocathodes in an X-ray streak camera and an update on the theoretical simulations to predict the optimum cathode curvature

  9. Streak cameras and their applications

    International Nuclear Information System (INIS)

    Bernet, J.M.; Imhoff, C.

    1987-01-01

    Over the last several years, development of various measurement techniques in the nanosecond and pico-second range has led to increased reliance on streak cameras. This paper will present the main electronic and optoelectronic performances of the Thomson-CSF TSN 506 cameras and their associated devices used to build an automatic image acquisition and processing system (NORMA). A brief survey of the diversity and the spread of the use of high speed electronic cinematography will be illustrated by a few typical applications [fr

  10. Improved approach to characterizing and presenting streak camera performance

    International Nuclear Information System (INIS)

    Wiedwald, J.D.; Jones, B.A.

    1985-01-01

    The performance of a streak camera recording system is strongly linked to the technique used to amplify, detect and quantify the streaked image. At the Lawrence Livermore National Laboratory (LLNL) streak camera images have been recorded both on film and by fiber-optically coupling to charge-coupled devices (CCD's). During the development of a new process for recording these images (lens coupling the image onto a cooled CCD) the definitions of important performance characteristics such as resolution and dynamic range were re-examined. As a result of this development, these performance characteristics are now presented to the streak camera user in a more useful format than in the past. This paper describes how these techniques are used within the Laser Fusion Program at LLNL. The system resolution is presented as a modulation transfer function, including the seldom reported effects that flare and light scattering have at low spatial frequencies. Data are presented such that a user can adjust image intensifier gain and pixel averaging to optimize the useful dynamic range in any particular application

  11. Characterization results from several commercial soft X-ray streak cameras

    Science.gov (United States)

    Stradling, G. L.; Studebaker, J. K.; Cavailler, C.; Launspach, J.; Planes, J.

    The spatio-temporal performance of four soft X-ray streak cameras has been characterized. The objective in evaluating the performance capability of these instruments is to enable us to optimize experiment designs, to encourage quantitative analysis of streak data and to educate the ultra high speed photography and photonics community about the X-ray detector performance which is available. These measurements have been made collaboratively over the space of two years at the Forge pulsed X-ray source at Los Alamos and at the Ketjak laser facility an CEA Limeil-Valenton. The X-ray pulse lengths used for these measurements at these facilities were 150 psec and 50 psec respectively. The results are presented as dynamically-measured modulation transfer functions. Limiting temporal resolution values were also calculated. Emphasis is placed upon shot noise statistical limitations in the analysis of the data. Space charge repulsion in the streak tube limits the peak flux at ultra short experiments duration times. This limit results in a reduction of total signal and a decrease in signal to no ise ratio in the streak image. The four cameras perform well with 20 1p/mm resolution discernable in data from the French C650X, the Hadland X-Chron 540 and the Hamamatsu C1936X streak cameras. The Kentech X-ray streak camera has lower modulation and does not resolve below 10 1p/mm but has a longer photocathode.

  12. A time-resolved image sensor for tubeless streak cameras

    Science.gov (United States)

    Yasutomi, Keita; Han, SangMan; Seo, Min-Woong; Takasawa, Taishi; Kagawa, Keiichiro; Kawahito, Shoji

    2014-03-01

    This paper presents a time-resolved CMOS image sensor with draining-only modulation (DOM) pixels for tube-less streak cameras. Although the conventional streak camera has high time resolution, the device requires high voltage and bulky system due to the structure with a vacuum tube. The proposed time-resolved imager with a simple optics realize a streak camera without any vacuum tubes. The proposed image sensor has DOM pixels, a delay-based pulse generator, and a readout circuitry. The delay-based pulse generator in combination with an in-pixel logic allows us to create and to provide a short gating clock to the pixel array. A prototype time-resolved CMOS image sensor with the proposed pixel is designed and implemented using 0.11um CMOS image sensor technology. The image array has 30(Vertical) x 128(Memory length) pixels with the pixel pitch of 22.4um. .

  13. Structured photocathodes for improved high-energy x-ray efficiency in streak cameras

    Energy Technology Data Exchange (ETDEWEB)

    Opachich, Y. P., E-mail: opachiyp@nv.doe.gov; Huffman, E.; Koch, J. A. [National Security Technologies, LLC, Livermore, California 94551 (United States); Bell, P. M.; Bradley, D. K.; Hatch, B.; Landen, O. L.; MacPhee, A. G.; Nagel, S. R. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Chen, N.; Gopal, A.; Udin, S. [Nanoshift LLC, Emeryville, California 94608 (United States); Feng, J. [Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Hilsabeck, T. J. [General Atomics, San Diego, California 92121 (United States)

    2016-11-15

    We have designed and fabricated a structured streak camera photocathode to provide enhanced efficiency for high energy X-rays (1–12 keV). This gold coated photocathode was tested in a streak camera and compared side by side against a conventional flat thin film photocathode. Results show that the measured electron yield enhancement at energies ranging from 1 to 10 keV scales well with predictions, and that the total enhancement can be more than 3×. The spatial resolution of the streak camera does not show degradation in the structured region. We predict that the temporal resolution of the detector will also not be affected as it is currently dominated by the slit width. This demonstration with Au motivates exploration of comparable enhancements with CsI and may revolutionize X-ray streak camera photocathode design.

  14. Design of microcontroller based system for automation of streak camera

    International Nuclear Information System (INIS)

    Joshi, M. J.; Upadhyay, J.; Deshpande, P. P.; Sharma, M. L.; Navathe, C. P.

    2010-01-01

    A microcontroller based system has been developed for automation of the S-20 optical streak camera, which is used as a diagnostic tool to measure ultrafast light phenomenon. An 8 bit MCS family microcontroller is employed to generate all control signals for the streak camera. All biasing voltages required for various electrodes of the tubes are generated using dc-to-dc converters. A high voltage ramp signal is generated through a step generator unit followed by an integrator circuit and is applied to the camera's deflecting plates. The slope of the ramp can be changed by varying values of the capacitor and inductor. A programmable digital delay generator has been developed for synchronization of ramp signal with the optical signal. An independent hardwired interlock circuit has been developed for machine safety. A LABVIEW based graphical user interface has been developed which enables the user to program the settings of the camera and capture the image. The image is displayed with intensity profiles along horizontal and vertical axes. The streak camera was calibrated using nanosecond and femtosecond lasers.

  15. Design of microcontroller based system for automation of streak camera.

    Science.gov (United States)

    Joshi, M J; Upadhyay, J; Deshpande, P P; Sharma, M L; Navathe, C P

    2010-08-01

    A microcontroller based system has been developed for automation of the S-20 optical streak camera, which is used as a diagnostic tool to measure ultrafast light phenomenon. An 8 bit MCS family microcontroller is employed to generate all control signals for the streak camera. All biasing voltages required for various electrodes of the tubes are generated using dc-to-dc converters. A high voltage ramp signal is generated through a step generator unit followed by an integrator circuit and is applied to the camera's deflecting plates. The slope of the ramp can be changed by varying values of the capacitor and inductor. A programmable digital delay generator has been developed for synchronization of ramp signal with the optical signal. An independent hardwired interlock circuit has been developed for machine safety. A LABVIEW based graphical user interface has been developed which enables the user to program the settings of the camera and capture the image. The image is displayed with intensity profiles along horizontal and vertical axes. The streak camera was calibrated using nanosecond and femtosecond lasers.

  16. Design of microcontroller based system for automation of streak camera

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, M. J.; Upadhyay, J.; Deshpande, P. P.; Sharma, M. L.; Navathe, C. P. [Laser Electronics Support Division, RRCAT, Indore 452013 (India)

    2010-08-15

    A microcontroller based system has been developed for automation of the S-20 optical streak camera, which is used as a diagnostic tool to measure ultrafast light phenomenon. An 8 bit MCS family microcontroller is employed to generate all control signals for the streak camera. All biasing voltages required for various electrodes of the tubes are generated using dc-to-dc converters. A high voltage ramp signal is generated through a step generator unit followed by an integrator circuit and is applied to the camera's deflecting plates. The slope of the ramp can be changed by varying values of the capacitor and inductor. A programmable digital delay generator has been developed for synchronization of ramp signal with the optical signal. An independent hardwired interlock circuit has been developed for machine safety. A LABVIEW based graphical user interface has been developed which enables the user to program the settings of the camera and capture the image. The image is displayed with intensity profiles along horizontal and vertical axes. The streak camera was calibrated using nanosecond and femtosecond lasers.

  17. A novel simultaneous streak and framing camera without principle errors

    Science.gov (United States)

    Jingzhen, L.; Fengshan, S.; Ningwen, L.; Xiangdong, G.; Bin, H.; Qingyang, W.; Hongyi, C.; Yi, C.; Xiaowei, L.

    2018-02-01

    A novel simultaneous streak and framing camera with continuous access, the perfect information of which is far more important for the exact interpretation and precise evaluation of many detonation events and shockwave phenomena, has been developed. The camera with the maximum imaging frequency of 2 × 106 fps and the maximum scanning velocity of 16.3 mm/μs has fine imaging properties which are the eigen resolution of over 40 lp/mm in the temporal direction and over 60 lp/mm in the spatial direction and the framing frequency principle error of zero for framing record, and the maximum time resolving power of 8 ns and the scanning velocity nonuniformity of 0.136%~-0.277% for streak record. The test data have verified the performance of the camera quantitatively. This camera, simultaneously gained frames and streak with parallax-free and identical time base, is characterized by the plane optical system at oblique incidence different from space system, the innovative camera obscura without principle errors, and the high velocity motor driven beryllium-like rotating mirror, made of high strength aluminum alloy with cellular lateral structure. Experiments demonstrate that the camera is very useful and reliable to take high quality pictures of the detonation events.

  18. Laser-based terahertz-field-driven streak camera for the temporal characterization of ultrashort processes

    Energy Technology Data Exchange (ETDEWEB)

    Schuette, Bernd

    2011-09-15

    In this work, a novel laser-based terahertz-field-driven streak camera is presented. It allows for a pulse length characterization of femtosecond (fs) extreme ultraviolet (XUV) pulses by a cross-correlation with terahertz (THz) pulses generated with a Ti:sapphire laser. The XUV pulses are emitted by a source of high-order harmonic generation (HHG) in which an intense near-infrared (NIR) fs laser pulse is focused into a gaseous medium. The design and characterization of a high-intensity THz source needed for the streak camera is also part of this thesis. The source is based on optical rectification of the same NIR laser pulse in a lithium niobate crystal. For this purpose, the pulse front of the NIR beam is tilted via a diffraction grating to achieve velocity matching between NIR and THz beams within the crystal. For the temporal characterization of the XUV pulses, both HHG and THz beams are focused onto a gas target. The harmonic radiation creates photoelectron wavepackets which are then accelerated by the THz field depending on its phase at the time of ionization. This principle adopted from a conventional streak camera and now widely used in attosecond metrology. The streak camera presented here is an advancement of a terahertz-field-driven streak camera implemented at the Free Electron Laser in Hamburg (FLASH). The advantages of the laser-based streak camera lie in its compactness, cost efficiency and accessibility, while providing the same good quality of measurements as obtained at FLASH. In addition, its flexibility allows for a systematic investigation of streaked Auger spectra which is presented in this thesis. With its fs time resolution, the terahertz-field-driven streak camera thereby bridges the gap between attosecond and conventional cameras. (orig.)

  19. Laser-based terahertz-field-driven streak camera for the temporal characterization of ultrashort processes

    International Nuclear Information System (INIS)

    Schuette, Bernd

    2011-09-01

    In this work, a novel laser-based terahertz-field-driven streak camera is presented. It allows for a pulse length characterization of femtosecond (fs) extreme ultraviolet (XUV) pulses by a cross-correlation with terahertz (THz) pulses generated with a Ti:sapphire laser. The XUV pulses are emitted by a source of high-order harmonic generation (HHG) in which an intense near-infrared (NIR) fs laser pulse is focused into a gaseous medium. The design and characterization of a high-intensity THz source needed for the streak camera is also part of this thesis. The source is based on optical rectification of the same NIR laser pulse in a lithium niobate crystal. For this purpose, the pulse front of the NIR beam is tilted via a diffraction grating to achieve velocity matching between NIR and THz beams within the crystal. For the temporal characterization of the XUV pulses, both HHG and THz beams are focused onto a gas target. The harmonic radiation creates photoelectron wavepackets which are then accelerated by the THz field depending on its phase at the time of ionization. This principle adopted from a conventional streak camera and now widely used in attosecond metrology. The streak camera presented here is an advancement of a terahertz-field-driven streak camera implemented at the Free Electron Laser in Hamburg (FLASH). The advantages of the laser-based streak camera lie in its compactness, cost efficiency and accessibility, while providing the same good quality of measurements as obtained at FLASH. In addition, its flexibility allows for a systematic investigation of streaked Auger spectra which is presented in this thesis. With its fs time resolution, the terahertz-field-driven streak camera thereby bridges the gap between attosecond and conventional cameras. (orig.)

  20. Compact streak camera for the shock study of solids by using the high-pressure gas gun

    Science.gov (United States)

    Nagayama, Kunihito; Mori, Yasuhito

    1993-01-01

    For the precise observation of high-speed impact phenomena, a compact high-speed streak camera recording system has been developed. The system consists of a high-pressure gas gun, a streak camera, and a long-pulse dye laser. The gas gun installed in our laboratory has a muzzle of 40 mm in diameter, and a launch tube of 2 m long. Projectile velocity is measured by the laser beam cut method. The gun is capable of accelerating a 27 g projectile up to 500 m/s, if helium gas is used as a driver. The system has been designed on the principal idea that the precise optical measurement methods developed in other areas of research can be applied to the gun study. The streak camera is 300 mm in diameter, with a rectangular rotating mirror which is driven by an air turbine spindle. The attainable streak velocity is 3 mm/microsecond(s) . The size of the camera is rather small aiming at the portability and economy. Therefore, the streak velocity is relatively slower than the fast cameras, but it is possible to use low-sensitivity but high-resolution film as a recording medium. We have also constructed a pulsed dye laser of 25 - 30 microsecond(s) in duration. The laser can be used as a light source of observation. The advantage for the use of the laser will be multi-fold, i.e., good directivity, almost single frequency, and so on. The feasibility of the system has been demonstrated by performing several experiments.

  1. Streak camera imaging of single photons at telecom wavelength

    Science.gov (United States)

    Allgaier, Markus; Ansari, Vahid; Eigner, Christof; Quiring, Viktor; Ricken, Raimund; Donohue, John Matthew; Czerniuk, Thomas; Aßmann, Marc; Bayer, Manfred; Brecht, Benjamin; Silberhorn, Christine

    2018-01-01

    Streak cameras are powerful tools for temporal characterization of ultrafast light pulses, even at the single-photon level. However, the low signal-to-noise ratio in the infrared range prevents measurements on weak light sources in the telecom regime. We present an approach to circumvent this problem, utilizing an up-conversion process in periodically poled waveguides in Lithium Niobate. We convert single photons from a parametric down-conversion source in order to reach the point of maximum detection efficiency of commercially available streak cameras. We explore phase-matching configurations to apply the up-conversion scheme in real-world applications.

  2. Performance of Laser Megajoule’s x-ray streak camera

    Energy Technology Data Exchange (ETDEWEB)

    Zuber, C., E-mail: celine.zuber@cea.fr; Bazzoli, S.; Brunel, P.; Burillo, M.; Gontier, D.; Moreau, I.; Oudot, G.; Rubbelynck, C.; Soullié, G.; Stemmler, P.; Trosseille, C. [CEA, DAM, DIF, F-91297 Arpajon (France); Fronty, J. P.; Goulmy, C. [Photonis France SAS, Avenue Roger Roncier, BP 520, 19106 Brive Cedex (France)

    2016-11-15

    A prototype of a picosecond x-ray streak camera has been developed and tested by Commissariat à l’Énergie Atomique et aux Énergies Alternatives to provide plasma-diagnostic support for the Laser Megajoule. We report on the measured performance of this streak camera, which almost fulfills the requirements: 50-μm spatial resolution over a 15-mm field in the photocathode plane, 17-ps temporal resolution in a 2-ns timebase, a detection threshold lower than 625 nJ/cm{sup 2} in the 0.05–15 keV spectral range, and a dynamic range greater than 100.

  3. Characteristics of uranium oxide cathode for neutron streak camera

    International Nuclear Information System (INIS)

    Niki, H.; Itoga, K.; Yamanaka, M.; Yamanaka, T.; Yamanaka, C.

    1986-01-01

    In laser fusion research, time-resolved neutron measurements require 20ps resolution in order to obtain the time history of the D-T burn. Uranium oxide was expected to be a sensitive material as a cathode of a neutron streak camera because of its large fission cross section. The authors report their measurements of some characteristics of the uranium oxide cathode connected to a conventional streak tube. 14 MeV neutron signal were observed as the bright spots on a TV monitor using a focus mode opration. Detection efficiency was ∼ 1 x 10 -6 for 1 μm thick cathode. Each signal consisted of more than several tens of components, which were corresponding to the secondary electrons dragged out from the cathode by a fission fragment. Time resolution is thought to be limited mainly by the transit time spread of the secondary electrons. 14ps resolution was obtained by a streak mode operation for a single fission event

  4. The LLL compact 10-ps streak camera

    International Nuclear Information System (INIS)

    Thomas, S.W.; Houghton, J.W.; Tripp, G.R.; Coleman, L.W.

    1975-01-01

    The 10-ps streak camera has been redesigned to simplify its operation, reduce manufacturing costs, and improve its appearance. The electronics have been simplified, a film indexer added, and a contacted slit has been evaluated. Data support a 10-ps resolution. (author)

  5. rf streak camera based ultrafast relativistic electron diffraction.

    Science.gov (United States)

    Musumeci, P; Moody, J T; Scoby, C M; Gutierrez, M S; Tran, T

    2009-01-01

    We theoretically and experimentally investigate the possibility of using a rf streak camera to time resolve in a single shot structural changes at the sub-100 fs time scale via relativistic electron diffraction. We experimentally tested this novel concept at the UCLA Pegasus rf photoinjector. Time-resolved diffraction patterns from thin Al foil are recorded. Averaging over 50 shots is required in order to get statistics sufficient to uncover a variation in time of the diffraction patterns. In the absence of an external pump laser, this is explained as due to the energy chirp on the beam out of the electron gun. With further improvements to the electron source, rf streak camera based ultrafast electron diffraction has the potential to yield truly single shot measurements of ultrafast processes.

  6. C.C.D. readout of a picosecond streak camera with an intensified C.C.D

    International Nuclear Information System (INIS)

    Lemonier, M.; Richard, J.C.; Cavailler, C.; Mens, A.; Raze, G.

    1984-08-01

    This paper deals with a digital streak camera readout device. The device consists in a low light level television camera made of a solid state C.C.D. array coupled to an image intensifier associated to a video-digitizer coupled to a micro-computer system. The streak camera images are picked-up as a video signal, digitized and stored. This system allows the fast recording and the automatic processing of the data provided by the streak tube

  7. Optical Comb Generation for Streak Camera Calibration for Inertial Confinement Fusion Experiments

    International Nuclear Information System (INIS)

    Ronald Justin; Terence Davies; Frans Janson; Bruce Marshall; Perry Bell; Daniel Kalantar; Joseph Kimbrough; Stephen Vernon; Oliver Sweningsen

    2008-01-01

    The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) is coming on-line to support physics experimentation for the U.S. Department of Energy (DOE) programs in Inertial Confinement Fusion (ICF) and Stockpile Stewardship (SS). Optical streak cameras are an integral part of the experimental diagnostics instrumentation at NIF. To accurately reduce streak camera data a highly accurate temporal calibration is required. This article describes a technique for simultaneously generating a precise +/- 2 ps optical marker pulse (fiducial reference) and trains of precisely timed, short-duration optical pulses (so-called 'comb' pulse trains) that are suitable for the timing calibrations. These optical pulse generators are used with the LLNL optical streak cameras. They are small, portable light sources that, in the comb mode, produce a series of temporally short, uniformly spaced optical pulses, using a laser diode source. Comb generators have been produced with pulse-train repetition rates up to 10 GHz at 780 nm, and somewhat lower frequencies at 664 nm. Individual pulses can be as short as 25-ps FWHM. Signal output is via a fiber-optic connector on the front panel of the generator box. The optical signal is transported from comb generator to streak camera through multi-mode, graded-index optical fiber

  8. Picosecond x-ray streak cameras

    Science.gov (United States)

    Averin, V. I.; Bryukhnevich, Gennadii I.; Kolesov, G. V.; Lebedev, Vitaly B.; Miller, V. A.; Saulevich, S. V.; Shulika, A. N.

    1991-04-01

    The first multistage image converter with an X-ray photocathode (UMI-93 SR) was designed in VNIIOFI in 1974 [1]. The experiments carried out in IOFAN pointed out that X-ray electron-optical cameras using the tube provided temporal resolution up to 12 picoseconds [2]. The later work has developed into the creation of the separate streak and intensifying tubes. Thus, PV-003R tube has been built on base of UMI-93SR design, fibre optically connected to PMU-2V image intensifier carrying microchannel plate.

  9. Commissioning of the advanced light source dual-axis streak camera

    International Nuclear Information System (INIS)

    Hinkson, J.; Keller, R.; Byrd, J.

    1997-05-01

    A dual-axis camera, Hamamatsu model C5680, has been installed on the Advanced Light Source photon-diagnostics beam-line to investigate electron-beam parameters. During its commissioning process, the camera has been used to measure single-bunch length vs. current, relative bunch charge in adjacent RF buckets, and bunchphase stability. In this paper the authors describe the visible-light branch of the diagnostics beam-line, the streak-camera installation, and the timing electronics. They will show graphical results of beam measurements taken during a variety of accelerator conditions

  10. Lasers and laser applications. Imaging implosion dynamics: The x-ray pinhole/streak camera

    International Nuclear Information System (INIS)

    Attwood, D.T.

    1976-01-01

    A Livermore-developed x-ray-sensitive streak camera was combined with a unique x-ray pinhole camera to make dynamic photographs of laser-irradiated fusion target implosions. These photographs show x radiation emitted from the imploding shell during its 100-ps implosion; they are the first continuous observations of an imploding laser-driven fusion capsule. The diagnostic system has a time resolution of 15 ps and a spatial resolution of about 6 μm. Results agree very well with those predicted by our LASNEX calculations, confirming that the essential physics are correctly described in the code and providing further confidence in the soundness of this approach to inertial confinement fusion

  11. STREAK CAMERA MEASUREMENTS OF THE APS PC GUN DRIVE LASER

    Energy Technology Data Exchange (ETDEWEB)

    Dooling, J. C.; Lumpkin, A. H.

    2017-06-25

    We report recent pulse-duration measurements of the APS PC Gun drive laser at both second harmonic and fourth harmonic wavelengths. The drive laser is a Nd:Glass-based chirped pulsed amplifier (CPA) operating at an IR wavelength of 1053 nm, twice frequency-doubled to obtain UV output for the gun. A Hamamatsu C5680 streak camera and an M5675 synchroscan unit are used for these measurements; the synchroscan unit is tuned to 119 MHz, the 24th subharmonic of the linac s-band operating frequency. Calibration is accomplished both electronically and optically. Electronic calibration utilizes a programmable delay line in the 119 MHz rf path. The optical delay uses an etalon with known spacing between reflecting surfaces and is coated for the visible, SH wavelength. IR pulse duration is monitored with an autocorrelator. Fitting the streak camera image projected profiles with Gaussians, UV rms pulse durations are found to vary from 2.1 ps to 3.5 ps as the IR varies from 2.2 ps to 5.2 ps.

  12. Development of intelligent control system for X-ray streak camera in diagnostic instrument manipulator

    International Nuclear Information System (INIS)

    Pei, Chengquan; Wu, Shengli; Tian, Jinshou; Liu, Zhen; Fang, Yuman; Gao, Guilong; Liang, Lingliang; Wen, Wenlong

    2015-01-01

    An intelligent control system for an X ray streak camera in a diagnostic instrument manipulator (DIM) is proposed and implemented, which can control time delay, electric focusing, image gain adjustment, switch of sweep voltage, acquiring environment parameters etc. The system consists of 16 A/D converters and 16 D/A converters, a 32-channel general purpose input/output (GPIO) and two sensors. An isolated DC/DC converter with multi-outputs and a single mode fiber were adopted to reduce the interference generated by the common ground among the A/D, D/A and I/O. The software was designed using graphical programming language and can remotely access the corresponding instrument from a website. The entire intelligent control system can acquire the desirable data at a speed of 30 Mb/s and store it for later analysis. The intelligent system was implemented on a streak camera in a DIM and it shows a temporal resolution of 11.25 ps, spatial distortion of less than 10% and dynamic range of 279:1. The intelligent control system has been successfully used in a streak camera to verify the synchronization of multi-channel laser on the Inertial Confinement Fusion Facility

  13. Development of intelligent control system for X-ray streak camera in diagnostic instrument manipulator

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Chengquan [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi' an 710049 (China); Wu, Shengli, E-mail: slwu@mail.xjtu.edu.cn [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi' an 710049 (China); Tian, Jinshou [Xi' an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); Liu, Zhen [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi' an 710049 (China); Fang, Yuman [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi' an 710049 (China); University of the Chinese Academy of Sciences, Beijing 100039 (China); Gao, Guilong; Liang, Lingliang [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi' an 710049 (China); Xi' an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); University of the Chinese Academy of Sciences, Beijing 100039 (China); Wen, Wenlong [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi' an 710049 (China)

    2015-11-01

    An intelligent control system for an X ray streak camera in a diagnostic instrument manipulator (DIM) is proposed and implemented, which can control time delay, electric focusing, image gain adjustment, switch of sweep voltage, acquiring environment parameters etc. The system consists of 16 A/D converters and 16 D/A converters, a 32-channel general purpose input/output (GPIO) and two sensors. An isolated DC/DC converter with multi-outputs and a single mode fiber were adopted to reduce the interference generated by the common ground among the A/D, D/A and I/O. The software was designed using graphical programming language and can remotely access the corresponding instrument from a website. The entire intelligent control system can acquire the desirable data at a speed of 30 Mb/s and store it for later analysis. The intelligent system was implemented on a streak camera in a DIM and it shows a temporal resolution of 11.25 ps, spatial distortion of less than 10% and dynamic range of 279:1. The intelligent control system has been successfully used in a streak camera to verify the synchronization of multi-channel laser on the Inertial Confinement Fusion Facility.

  14. Improving the off-axis spatial resolution and dynamic range of the NIF X-ray streak cameras (invited)

    Energy Technology Data Exchange (ETDEWEB)

    MacPhee, A. G., E-mail: macphee2@llnl.gov; Hatch, B. W.; Bell, P. M.; Bradley, D. K.; Datte, P. S.; Landen, O. L.; Palmer, N. E.; Piston, K. W.; Rekow, V. V. [Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551-0808 (United States); Dymoke-Bradshaw, A. K. L.; Hares, J. D. [Kentech Instruments Ltd., Isis Building, Howbery Park, Wallingford, Oxfordshire OX10 8BD (United Kingdom); Hassett, J. [Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551-0808 (United States); Department of Electrical and Computer Engineering, University of Rochester, Rochester, New York 14627 (United States); Meadowcroft, A. L. [AWE Aldermaston, Reading, Berkshire RG7 4PR (United Kingdom); Hilsabeck, T. J.; Kilkenny, J. D. [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States)

    2016-11-15

    We report simulations and experiments that demonstrate an increase in spatial resolution of the NIF core diagnostic x-ray streak cameras by at least a factor of two, especially off axis. A design was achieved by using a corrector electron optic to flatten the field curvature at the detector plane and corroborated by measurement. In addition, particle in cell simulations were performed to identify the regions in the streak camera that contribute the most to space charge blurring. These simulations provide a tool for convolving synthetic pre-shot spectra with the instrument function so signal levels can be set to maximize dynamic range for the relevant part of the streak record.

  15. Improving the off-axis spatial resolution and dynamic range of the NIF X-ray streak cameras (invited).

    Science.gov (United States)

    MacPhee, A G; Dymoke-Bradshaw, A K L; Hares, J D; Hassett, J; Hatch, B W; Meadowcroft, A L; Bell, P M; Bradley, D K; Datte, P S; Landen, O L; Palmer, N E; Piston, K W; Rekow, V V; Hilsabeck, T J; Kilkenny, J D

    2016-11-01

    We report simulations and experiments that demonstrate an increase in spatial resolution of the NIF core diagnostic x-ray streak cameras by at least a factor of two, especially off axis. A design was achieved by using a corrector electron optic to flatten the field curvature at the detector plane and corroborated by measurement. In addition, particle in cell simulations were performed to identify the regions in the streak camera that contribute the most to space charge blurring. These simulations provide a tool for convolving synthetic pre-shot spectra with the instrument function so signal levels can be set to maximize dynamic range for the relevant part of the streak record.

  16. Cheap streak camera based on the LD-S-10 intensifier tube

    Science.gov (United States)

    Dashevsky, Boris E.; Krutik, Mikhail I.; Surovegin, Alexander L.

    1992-01-01

    Basic properties of a new streak camera and its test results are reported. To intensify images on its screen, we employed modular G1 tubes, the LD-A-1.0 and LD-A-0.33, enabling magnification of 1.0 and 0.33, respectively. If necessary, the LD-A-0.33 tube may be substituted by any other image intensifier of the LDA series, the choice to be determined by the size of the CCD matrix with fiber-optical windows. The reported camera employs a 12.5- mm-long CCD strip consisting of 1024 pixels, each 12 X 500 micrometers in size. Registered radiation was imaged on a 5 X 0.04 mm slit diaphragm tightly connected with the LD-S- 10 fiber-optical input window. Electrons escaping the cathode are accelerated in a 5 kV electric field and focused onto a phosphor screen covering a fiber-optical plate as they travel between deflection plates. Sensitivity of the latter was 18 V/mm, which implies that the total deflecting voltage was 720 V per 40 mm of the screen surface, since reversed-polarity scan pulses +360 V and -360 V were applied across the deflection plate. The streak camera provides full scan times over the screen of 15, 30, 50, 100, 250, and 500 ns. Timing of the electrically or optically driven camera was done using a 10 ns step-controlled-delay (0 - 500 ns) circuit.

  17. Precise measurement of a subpicosecond electron single bunch by the femtosecond streak camera

    International Nuclear Information System (INIS)

    Uesaka, M.; Ueda, T.; Kozawa, T.; Kobayashi, T.

    1998-01-01

    Precise measurement of a subpicosecond electron single bunch by the femtosecond streak camera is presented. The subpicosecond electron single bunch of energy 35 MeV was generated by the achromatic magnetic pulse compressor at the S-band linear accelerator of nuclear engineering research laboratory (NERL), University of Tokyo. The electric charge per bunch and beam size are 0.5 nC and the horizontal and vertical beam sizes are 3.3 and 5.5 mm (full width at half maximum; FWHM), respectively. Pulse shape of the electron single bunch is measured via Cherenkov radiation emitted in air by the femtosecond streak camera. Optical parameters of the optical measurement system were optimized based on much experiment and numerical analysis in order to achieve a subpicosecond time resolution. By using the optimized optical measurement system, the subpicosecond pulse shape, its variation for the differents rf phases in the accelerating tube, the jitter of the total system and the correlation between measured streak images and calculated longitudinal phase space distributions were precisely evaluated. This measurement system is going to be utilized in several subpicosecond analyses for radiation physics and chemistry. (orig.)

  18. Ultrafast streak and framing technique for the observation of laser driven shock waves in transparent solid targets

    International Nuclear Information System (INIS)

    Van Kessel, C.G.M.; Sachsenmaier, P.; Sigel, R.

    1975-01-01

    Shock waves driven by laser ablation in plane transparent plexiglass and solid hydrogen targets have been observed with streak and framing techniques using a high speed image converter camera, and a dye laser as a light source. The framing pictures have been made by mode locking the dye laser and using a wide streak slit. In both materials a growing hemispherical shock wave is observed with the maximum velocity at the onset of laser radiation. (author)

  19. Temporal resolution limit estimation of x-ray streak cameras using a CsI photocathode

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xiang; Gu, Li; Zong, Fangke; Zhang, Jingjin; Yang, Qinlao, E-mail: qlyang@szu.edu.cn [Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, Institute of Optoelectronics, Shenzhen University, Shenzhen 518060 (China)

    2015-08-28

    A Monte Carlo model is developed and implemented to calculate the characteristics of x-ray induced secondary electron (SE) emission from a CsI photocathode used in an x-ray streak camera. Time distributions of emitted SEs are investigated with an incident x-ray energy range from 1 to 30 keV and a CsI thickness range from 100 to 1000 nm. Simulation results indicate that SE time distribution curves have little dependence on the incident x-ray energy and CsI thickness. The calculated time dispersion within the CsI photocathode is about 70 fs, which should be the temporal resolution limit of x-ray streak cameras that use CsI as the photocathode material.

  20. Compact optical technique for streak camera calibration

    International Nuclear Information System (INIS)

    Bell, Perry; Griffith, Roger; Hagans, Karla; Lerche, Richard; Allen, Curt; Davies, Terence; Janson, Frans; Justin, Ronald; Marshall, Bruce; Sweningsen, Oliver

    2004-01-01

    To produce accurate data from optical streak cameras requires accurate temporal calibration sources. We have reproduced an older technology for generating optical timing marks that had been lost due to component availability. Many improvements have been made which allow the modern units to service a much larger need. Optical calibrators are now available that produce optical pulse trains of 780 nm wavelength light at frequencies ranging from 0.1 to 10 GHz, with individual pulse widths of approximately 25 ps full width half maximum. Future plans include the development of single units that produce multiple frequencies to cover a wide temporal range, and that are fully controllable via an RS232 interface

  1. Compact optical technique for streak camera calibration

    Science.gov (United States)

    Bell, Perry; Griffith, Roger; Hagans, Karla; Lerche, Richard; Allen, Curt; Davies, Terence; Janson, Frans; Justin, Ronald; Marshall, Bruce; Sweningsen, Oliver

    2004-10-01

    To produce accurate data from optical streak cameras requires accurate temporal calibration sources. We have reproduced an older technology for generating optical timing marks that had been lost due to component availability. Many improvements have been made which allow the modern units to service a much larger need. Optical calibrators are now available that produce optical pulse trains of 780 nm wavelength light at frequencies ranging from 0.1 to 10 GHz, with individual pulse widths of approximately 25 ps full width half maximum. Future plans include the development of single units that produce multiple frequencies to cover a wide temporal range, and that are fully controllable via an RS232 interface.

  2. Sweep time performance of optic streak camera

    International Nuclear Information System (INIS)

    Wang Zhebin; Yang Dong; Zhang Huige

    2012-01-01

    The sweep time performance of the optic streak camera (OSC) is of critical importance to its application. The systematic analysis of full-screen sweep velocity shows that the traditional method based on the averaged velocity and its nonlinearity would increase the uncertainty of sweep time and can not reflect the influence of the spatial distortion of OSC. A elaborate method for sweep time has been developed with the aid of full-screen sweep velocity and its uncertainty. It is proved by the theoretical analysis and experimental study that the method would decrease the uncertainty of sweep time within 1%, which would improve the accuracy of sweep time and the reliability of OSC application. (authors)

  3. A Robust In-Situ Warp-Correction Algorithm For VISAR Streak Camera Data at the National Ignition Facility

    International Nuclear Information System (INIS)

    Labaria, George R.; Warrick, Abbie L.; Celliers, Peter M.; Kalantar, Daniel H.

    2015-01-01

    The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory is a 192-beam pulsed laser system for high-energy-density physics experiments. Sophisticated diagnostics have been designed around key performance metrics to achieve ignition. The Velocity Interferometer System for Any Reflector (VISAR) is the primary diagnostic for measuring the timing of shocks induced into an ignition capsule. The VISAR system utilizes three streak cameras; these streak cameras are inherently nonlinear and require warp corrections to remove these nonlinear effects. A detailed calibration procedure has been developed with National Security Technologies (NSTec) and applied to the camera correction analysis in production. However, the camera nonlinearities drift over time, affecting the performance of this method. An in-situ fiber array is used to inject a comb of pulses to generate a calibration correction in order to meet the timing accuracy requirements of VISAR. We develop a robust algorithm for the analysis of the comb calibration images to generate the warp correction that is then applied to the data images. Our algorithm utilizes the method of thin-plate splines (TPS) to model the complex nonlinear distortions in the streak camera data. In this paper, we focus on the theory and implementation of the TPS warp-correction algorithm for the use in a production environment.

  4. A Robust In-Situ Warp-Correction Algorithm For VISAR Streak Camera Data at the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Labaria, George R. [Univ. of California, Santa Cruz, CA (United States); Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Warrick, Abbie L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Celliers, Peter M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kalantar, Daniel H. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-01-12

    The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory is a 192-beam pulsed laser system for high-energy-density physics experiments. Sophisticated diagnostics have been designed around key performance metrics to achieve ignition. The Velocity Interferometer System for Any Reflector (VISAR) is the primary diagnostic for measuring the timing of shocks induced into an ignition capsule. The VISAR system utilizes three streak cameras; these streak cameras are inherently nonlinear and require warp corrections to remove these nonlinear effects. A detailed calibration procedure has been developed with National Security Technologies (NSTec) and applied to the camera correction analysis in production. However, the camera nonlinearities drift over time, affecting the performance of this method. An in-situ fiber array is used to inject a comb of pulses to generate a calibration correction in order to meet the timing accuracy requirements of VISAR. We develop a robust algorithm for the analysis of the comb calibration images to generate the warp correction that is then applied to the data images. Our algorithm utilizes the method of thin-plate splines (TPS) to model the complex nonlinear distortions in the streak camera data. In this paper, we focus on the theory and implementation of the TPS warp-correction algorithm for the use in a production environment.

  5. Identification and Removal of High Frequency Temporal Noise in a Nd:YAG Macro-Pulse Laser Assisted with a Diagnostic Streak Camera

    International Nuclear Information System (INIS)

    Kent Marlett; Ke-Xun Sun

    2004-01-01

    This paper discusses the use of a reference streak camera (SC) to diagnose laser performance and guide modifications to remove high frequency noise from Bechtel Nevada's long-pulse laser. The upgraded laser exhibits less than 0.1% high frequency noise in cumulative spectra, exceeding National Ignition Facility (NIF) calibration specifications. Inertial Confinement Fusion (ICF) experiments require full characterization of streak cameras over a wide range of sweep speeds (10 ns to 480 ns). This paradigm of metrology poses stringent spectral requirements on the laser source for streak camera calibration. Recently, Bechtel Nevada worked with a laser vendor to develop a high performance, multi-wavelength Nd:YAG laser to meet NIF calibration requirements. For a typical NIF streak camera with a 4096 x 4096 pixel CCD, the flat field calibration at 30 ns requires a smooth laser spectrum over 33 MHz to 68 GHz. Streak cameras are the appropriate instrumentation for measuring laser amplitude noise at these very high frequencies since the upper end spectral content is beyond the frequency response of typical optoelectronic detectors for a single shot pulse. The SC was used to measure a similar laser at its second harmonic wavelength (532 nm), to establish baseline spectra for testing signal analysis algorithms. The SC was then used to measure the new custom calibration laser. In both spatial-temporal measurements and cumulative spectra, 6-8 GHz oscillations were identified. The oscillations were found to be caused by inter-surface reflections between amplifiers. Additional variations in the SC spectral data were found to result from temperature instabilities in the seeding laser. Based on these findings, laser upgrades were made to remove the high frequency noise from the laser output

  6. Towards jitter free synchronization of synchroscan streak cameras by noisy periodic laser pulses

    International Nuclear Information System (INIS)

    Cunin, B.; Heisel, F.; Miehe, J.A.

    1991-01-01

    In connection with the parameters characterizing the phase noise in cw mode-locked lasers and under the employ of streak cameras operated by sinewave deflection, the timing capabilities of the measuring system for two commonly used synchronization techniques are discussed by stochastic description. Especially, the power spectrum of the sweep signal versus the laser phase noise is examined in detail. The theoretical results are used to interpret experimental observations recorded by means of actively and passively mode-locked lasers. One of the interesting applications of synchroscan operations to metrology is the determination of short-term instabilities of the oscillator on a time scale near to the period. (author) 12 refs.; 3 figs

  7. Streak camera measurements of laser pulse temporal dispersion in short graded-index optical fibers

    International Nuclear Information System (INIS)

    Lerche, R.A.; Phillips, G.E.

    1981-01-01

    Streak camera measurements were used to determine temporal dispersion in short (5 to 30 meter) graded-index optical fibers. Results show that 50-ps, 1.06-μm and 0.53-μm laser pulses can be propagated without significant dispersion when care is taken to prevent propagation of energy in fiber cladding modes

  8. A sampling ultra-high-speed streak camera based on the use of a unique photomultiplier

    International Nuclear Information System (INIS)

    Marode, Emmanuel

    An apparatus reproducing the ''streak'' mode of a high-speed camera is proposed for the case of a slit AB whose variations in luminosity are repetitive. A photomultiplier, analysing the object AB point by point, and a still camera, photographing a slit fixed on the oscilloscope screen parallel to the sweep direction are placed on a mobile platform P. The movement of P assures a time-resolved analysis of AB. The resolution is of the order of 2.10 -9 s, and can be improved [fr

  9. Synchronization of streak and framing camera measurements of an intense relativistic electron beam propagating through gas

    International Nuclear Information System (INIS)

    Weidman, D.J.; Murphy, D.P.; Myers, M.C.; Meger, R.A.

    1994-01-01

    The expansion of the radius of a 5 MeV, 20 kA, 40 ns electron beam from SuperIBEX during propagation through gas is being measured. The beam is generated, conditions, equilibrated, and then passed through a thin foil that produces Cherenkov light, which is recorded by a streak camera. At a second location, the beam hits another Cherenkov emitter, which is viewed by a framing camera. Measurements at these two locations can provide a time-resolved measure of the beam expansion. The two measurements, however, must be synchronized with each other, because the beam radius is not constant throughout the pulse due to variations in beam current and energy. To correlate the timing of the two diagnostics, several shots have been taken with both diagnostics viewing Cherenkov light from the same foil. Experimental measurements of the Cherenkov light from one foil viewed by both diagnostics will be presented to demonstrate the feasibility of correlating the diagnostics with each other. Streak camera data showing the optical fiducial, as well as the final correlation of the two diagnostics, will also be presented. Preliminary beam radius measurements from Cherenkov light measured at two locations will be shown

  10. Light field driven streak-camera for single-shot measurements of the temporal profile of XUV-pulses from a free-electron laser; Lichtfeld getriebene Streak-Kamera zur Einzelschuss Zeitstrukturmessung der XUV-Pulse eines Freie-Elektronen Lasers

    Energy Technology Data Exchange (ETDEWEB)

    Fruehling, Ulrike

    2009-10-15

    The Free Electron Laser in Hamburg (FLASH) is a source for highly intense ultra short extreme ultraviolet (XUV) light pulses with pulse durations of a few femtoseconds. Due to the stochastic nature of the light generation scheme based on self amplified spontaneous emission (SASE), the duration and temporal profile of the XUV pulses fluctuate from shot to shot. In this thesis, a THz-field driven streak-camera capable of single pulse measurements of the XUV pulse-profile has been realized. In a first XUV-THz pump-probe experiment at FLASH, the XUV-pulses are overlapped in a gas target with synchronized THz-pulses generated by a new THz-undulator. The electromagnetic field of the THz light accelerates photoelectrons produced by the XUV-pulses with the resulting change of the photoelectron momenta depending on the phase of the THz field at the time of ionisation. This technique is intensively used in attosecond metrology where near infrared streaking fields are employed for the temporal characterisation of attosecond XUV-Pulses. Here, it is adapted for the analysis of pulse durations in the few femtosecond range by choosing a hundred times longer far infrared streaking wavelengths. Thus, the gap between conventional streak cameras with typical resolutions of hundreds of femtoseconds and techniques with attosecond resolution is filled. Using the THz-streak camera, the time dependent electric field of the THz-pulses was sampled in great detail while on the other hand the duration and even details of the time structure of the XUV-pulses were characterized. (orig.)

  11. Overall comparison of subpicosecond electron beam diagnostics by the polychromator, the interferometer and the femtosecond streak camera

    CERN Document Server

    Watanabe, T; Yoshimatsu, T; Sasaki, S; Sugiyama, Y; Ishi, K; Shibata, Y; Kondo, Y; Yoshii, K; Ueda, T; Uesaka, M

    2002-01-01

    Measurements of longitudinal bunch length of subpicosecond and picosecond electron beams have been performed by three methods with three radiation sources at the 35 MeV S-band twin liner accelerators at Nuclear Engineering Research Laboratory, University of Tokyo. The methods we adopt are the femtosecond streak camera with a nondispersive reflective optics, the coherent transition radiation (CTR) Michelson interferometer and the 10 ch polychromator that detects the spectrum of CTR and coherent diffraction radiation (CDR). The measurements by the two CTR methods were independently done with the streak camera and their results were consistent with one another. As a result, the reliability of the polychromator for the diagnostics of less than picosecond electron bunch and the usefulness of the diagnostics for the single shot measurement were verified. Furthermore, perfect nondestructive diagnostics for subpicosecond bunches was performed utilizing CDR interferometry. Then the good agreement between CDR interfero...

  12. Development and performance test of picosecond pulse x-ray excited streak camera system for scintillator characterization

    International Nuclear Information System (INIS)

    Yanagida, Takayuki; Fujimoto, Yutaka; Yoshikawa, Akira

    2010-01-01

    To observe time and wavelength-resolved scintillation events, picosecond pulse X-ray excited streak camera system is developed. The wavelength range spreads from vacuum ultraviolet (VUV) to near infrared region (110-900 nm) and the instrumental response function is around 80 ps. This work describes the principle of the newly developed instrument and the first performance test using BaF 2 single crystal scintillator. Core valence luminescence of BaF 2 peaking around 190 and 220 nm is clearly detected by our system, and the decay time turned out to be of 0.7 ns. These results are consistent with literature and confirm that our system properly works. (author)

  13. Picosecond streak camera diagnostics of CO2 laser-produced plasmas

    International Nuclear Information System (INIS)

    Jaanimagi, P.A.; Marjoribanks, R.S.; Sancton, R.W.; Enright, G.D.; Richardson, M.C.

    1979-01-01

    The interaction of intense laser radiation with solid targets is currently of considerable interest in laser fusion studies. Its understanding requires temporal knowledge of both laser and plasma parameters on a picosecond time scale. In this paper we describe the progress we have recently made in analysing, with picosecond time resolution, various features of intense nanosecond CO 2 laser pulse interaction experiments. An infrared upconversion scheme, having linear response and <20 ps temporal resolution, has been utilized to characterise the 10 μm laser pulse. Various features of the interaction have been studied with the aid of picosecond IR and x-ray streak cameras. These include the temporal and spatial characteristics of high harmonic emission from the plasma, and the temporal development of the x-ray continuum spectrum. (author)

  14. Aluminum-coated optical fibers as efficient infrared timing fiducial photocathodes for synchronizing x-ray streak cameras

    International Nuclear Information System (INIS)

    Koch, J.A.; MacGowan, B.J.

    1991-01-01

    The timing fiducial system at the Nova Two-Beam Facility allows time-resolved x-ray and optical streak camera data from laser-produced plasmas to be synchronized to within 30 ps. In this system, an Al-coated optical fiber is inserted into an aperture in the cathode plate of each streak camera. The coating acts as a photocathode for a low-energy pulse of 1ω (λ = 1.054 μm) light which is synchronized to the main Nova beam. The use of the fundamental (1ω) for this fiducial pulse has been found to offer significant advantages over the use of the 2ω second harmonic (λ = 0.53 μm). These advantages include brighter signals, greater reliability, and a higher relative damage threshold, allowing routine use without fiber replacement. The operation of the system is described, and experimental data and interpretations are discussed which suggest that the electron production in the Al film is due to thermionic emission. The results of detailed numerical simulations of the relevant thermal processes, undertaken to model the response of the coated fiber to 1ω laser pulses, are also presented, which give qualitative agreement with experimental data. Quantitative discrepancies between the modeling results and the experimental data are discussed, and suggestions for further research are given

  15. Streak electronic camera with slow-scanning storage tube used in the field of high-speed cineradiography

    International Nuclear Information System (INIS)

    Marilleau, J.; Bonnet, L.; Garcin, G.; Guix, R.; Loichot, R.

    The cineradiographic machine designed for measurements in the field of detonics consists of a linear accelerator associated with a braking target, a scintillator and a remote controlled electronic camera. The quantum factor of X-ray detection and the energetic efficiency of the scintillator are given. The electronic camera is built upon a deflection-converter tube (RCA C. 73 435 AJ) coupled by optical fibres to a photosensitive storage tube (TH-CSF Esicon) used in a slow-scanning process with electronic recording of the information. The different parts of the device are described. Some capabilities such as data processing numerical outputs, measurements and display are outlined. A streak cineradiogram of a typical implosion experiment is given [fr

  16. Streak-Camera Measurements with High Currents in PEP-II and Variable Optics in SPEAR3

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Weixeng; Fisher, Alan, a Corbett, Jeff; /SLAC

    2008-06-05

    A dual-axis, synchroscan streak camera was used to measure longitudinal bunch profiles in three storage rings at SLAC: the PEP-II low- and high-energy rings, and SPEAR3. At high currents, both PEP rings exhibit a transient synchronous-phase shift along the bunch train due to RF-cavity beam loading. Bunch length and profile asymmetry were measured along the train for a range of beam currents. To avoid the noise inherent in a dual-axis sweep, we accumulated single-axis synchroscan images while applying a 50-ns gate to the microchannel plate. To improve the extinction ratio, an upstream mirror pivoting at 1 kHz was synchronized with the 2kHz MCP gate to deflect light from other bunches off the photocathode. Bunch length was also measured on the HER as a function of beam energy. For SPEAR3 we measured bunch length as a function of single-bunch current for several lattices: achromatic, low-emittance and low momentum compaction. In the first two cases, resistive and reactive impedance components can be extracted from the longitudinal bunch profiles. In the low-alpha configurations, we observed natural bunch lengths approaching the camera resolution, requiring special care to remove instrumental effects, and saw evidence of periodic bursting.

  17. StreakDet data processing and analysis pipeline for space debris optical observations

    Science.gov (United States)

    Virtanen, Jenni; Flohrer, Tim; Muinonen, Karri; Granvik, Mikael; Torppa, Johanna; Poikonen, Jonne; Lehti, Jussi; Santti, Tero; Komulainen, Tuomo; Naranen, Jyri

    We describe a novel data processing and analysis pipeline for optical observations of space debris. The monitoring of space object populations requires reliable acquisition of observational data, to support the development and validation of space debris environment models, the build-up and maintenance of a catalogue of orbital elements. In addition, data is needed for the assessment of conjunction events and for the support of contingency situations or launches. The currently available, mature image processing algorithms for detection and astrometric reduction of optical data cover objects that cross the sensor field-of-view comparably slowly, and within a rather narrow, predefined range of angular velocities. By applying specific tracking techniques, the objects appear point-like or as short trails in the exposures. However, the general survey scenario is always a “track before detect” problem, resulting in streaks, i.e., object trails of arbitrary lengths, in the images. The scope of the ESA-funded StreakDet (Streak detection and astrometric reduction) project is to investigate solutions for detecting and reducing streaks from optical images, particularly in the low signal-to-noise ratio (SNR) domain, where algorithms are not readily available yet. For long streaks, the challenge is to extract precise position information and related registered epochs with sufficient precision. Although some considerations for low-SNR processing of streak-like features are available in the current image processing and computer vision literature, there is a need to discuss and compare these approaches for space debris analysis, in order to develop and evaluate prototype implementations. In the StreakDet project, we develop algorithms applicable to single images (as compared to consecutive frames of the same field) obtained with any observing scenario, including space-based surveys and both low- and high-altitude populations. The proposed processing pipeline starts from the

  18. Evaluation of dynamic range for LLNL streak cameras using high contrast pulsed and pulse podiatry on the Nova laser system

    International Nuclear Information System (INIS)

    Richards, J.B.; Weiland, T.L.; Prior, J.A.

    1990-01-01

    This paper reports on a standard LLNL streak camera that has been used to analyze high contrast pulses on the Nova laser facility. These pulses have a plateau at their leading edge (foot) with an amplitude which is approximately 1% of the maximum pulse height. Relying on other features of the pulses and on signal multiplexing, we were able to determine how accurately the foot amplitude was being represented by the camera. Results indicate that the useful single channel dynamic range of the instrument approaches 100:1

  19. Time- and wavelength-resolved luminescence evaluation of several types of scintillators using streak camera system equipped with pulsed X-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Furuya, Yuki, E-mail: f.yuki@mail.tagen.tohoku.ac.j [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); Yanagida, Takayuki; Fujimoto, Yutaka; Yokota, Yuui; Kamada, Kei [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); Kawaguchi, Noriaki [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); Research and Development Division, Tokuyama., Co. Ltd., ICR-Building, Minamiyoshinari, Aoba-ku, Sendai (Japan); Ishizu, Sumito [Research and Development Division, Tokuyama., Co. Ltd., ICR-Building, Minamiyoshinari, Aoba-ku, Sendai (Japan); Uchiyama, Koro; Mori, Kuniyoshi [Hamamatsu Photonics K.K., 325-6, Sunayama-cho, Naka-ku, Hamamatsu, Shizuoka 430-8587 (Japan); Kitano, Ken [Vacuum and Optical Instruments, 2-18-18 Shimomaruko, Ota, Tokyo 146-0092 (Japan); Nikl, Martin [Institute of Physics ASCR, Cukrovarnicka 10, Prague 6, 162-53 (Czech Republic); Yoshikawa, Akira [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); NICHe, Tohoku University, 6-6-10 Aoba, Aramaki, Aoba-ku, Sendai 980-8579 (Japan)

    2011-04-01

    To design new scintillating materials, it is very important to understand detailed information about the events, which occurred during the excitation and emission processes under the ionizing radiation excitation. We developed a streak camera system equipped with picosecond pulsed X-ray source to observe time- and wavelength-resolved scintillation events. In this report, we test the performance of this new system using several types of scintillators including bulk oxide/halide crystals, transparent ceramics, plastics and powders. For all samples, the results were consistent with those reported previously. The results demonstrated that the developed system is suitable for evaluation of the scintillation properties.

  20. Fiber scintillator/streak camera detector for burn history measurement in inertial confinement fusion experiment

    International Nuclear Information System (INIS)

    Miyanaga, N.; Ohba, N.; Fujimoto, K.

    1997-01-01

    To measure the burn history in an inertial confinement fusion experiment, we have developed a new neutron detector based on plastic scintillation fibers. Twenty-five fiber scintillators were arranged in a geometry compensation configuration by which the time-of-flight difference of the neutrons is compensated by the transit time difference of light passing through the fibers. Each fiber scintillator is spliced individually to an ultraviolet optical fiber that is coupled to a streak camera. We have demonstrated a significant improvement of sensitivity compared with the usual bulk scintillator coupled to a bundle of the same ultraviolet fibers. copyright 1997 American Institute of Physics

  1. Multislit streak photography for plasma dynamics studies

    International Nuclear Information System (INIS)

    Tou, T.Y.; Lee, S.

    1988-01-01

    A microscope slide with several transparent slits installed in a streak camera is used to record time-resolved two-dimensional information when a curved luminous plasma sheath traverses these slits. Applying this method to the plasma focus experiment, the axial run-down trajectory and the shapes of the plasma sheath at various moments can be obtained from a single streak photograph

  2. Streak tube development

    International Nuclear Information System (INIS)

    Hinrichs, C.K.; Estrella, R.M.

    1979-01-01

    A research program for the development of a high-speed, high-resolution streak image tube is described. This is one task in the development of a streak camera system with digital electronic readout, whose primary application is for diagnostics in underground nuclear testing. This program is concerned with the development of a high-resolution streak image tube compatible with x-ray input and electronic digital output. The tube must be capable of time resolution down to 100 psec and spatial resolution to provide greater than 1000 resolution elements across the cathode (much greater than presently available). Another objective is to develop the capability to make design changes in tube configurations to meet different experimental requirements. A demountable prototype streak tube was constructed, mounted on an optical bench, and placed in a vacuum system. Initial measurements of the tube resolution with an undeflected image show a resolution of 32 line pairs per millimeter over a cathode diameter of one inch, which is consistent with the predictions of the computer simulations. With the initial set of unoptmized deflection plates, the resolution pattern appeared to remain unchanged for static deflections of +- 1/2-inch, a total streak length of one inch, also consistent with the computer simulations. A passively mode-locked frequency-doubled dye laser is being developed as an ultraviolet pulsed light source to measure dynamic tube resolution during streaking. A sweep circuit to provide the deflection voltage in the prototype tube has been designed and constructed and provides a relatively linear ramp voltage with ramp durations adjustable between 10 and 1000 nsec

  3. Deflection system of a high-speed streak camera in the form of a delay line

    International Nuclear Information System (INIS)

    Korzhenevich, I.M.; Fel'dman, G.G.

    1993-01-01

    This paper presents an analysis of the operation of a meander deflection system, well-known in oscillography, when it is used to scan the image in a streak-camera tube. Effects that are specific to high-speed photography are considered. It is shown that such a deflection system imposes reduced requirements both on the steepness and on the duration of the linear leading edges of the pulses of the spark gaps that generate the sweep voltage. An example of the design of a meander deflection system whose sensitivity is a factor of two higher than for a conventional system is considered. 5 refs., 3 figs

  4. Evaluation of dynamic range for LLNL streak cameras using high contrast pulses and pulse podiatry'' on the Nova laser system

    Energy Technology Data Exchange (ETDEWEB)

    Richards, J.B.; Weiland, T.L.; Prior, J.A.

    1990-07-01

    A standard LLNL streak camera has been used to analyze high contrast pulses on the Nova laser facility. These pulses have a plateau at their leading edge (foot) with an amplitude which is approximately 1% of the maximum pulse height. Relying on other features of the pulses and on signal multiplexing, we were able to determine how accurately the foot amplitude was being represented by the camera. Results indicate that the useful single channel dynamic range of the instrument approaches 100:1. 1 ref., 4 figs., 1 tab.

  5. Realization of an optical multi and mono-channel analyzer, associated to a streak camera. Application to metrology of picosecond low intensity luminous pulses

    International Nuclear Information System (INIS)

    Roth, J.M.

    1985-02-01

    An electronic system including a low light level television tube (Nocticon) to digitize images from streak cameras is studied and realized. Performances (sensibility, signal-to-noise ratio) are studied and compared with a multi-channel analyzer using a linear network of photodiodes. It is applied to duration and amplitude measurement of short luminous pulses [fr

  6. Large-grazing-angle, multi-image Kirkpatrick-Baez microscope as the front end to a high-resolution streak camera for OMEGA

    International Nuclear Information System (INIS)

    Gotchev, O.V.; Hayes, L.J.; Jaanimagi, P.A.; Knauer, J.P.; Marshall, F.J.; Meyerhofer, D.D.

    2003-01-01

    A high-resolution x-ray microscope with a large grazing angle has been developed, characterized, and fielded at the Laboratory for Laser Energetics. It increases the sensitivity and spatial resolution in planar direct-drive hydrodynamic stability experiments, relevant to inertial confinement fusion research. It has been designed to work as the optical front end of the PJX - a high-current, high-dynamic-range x-ray streak camera. Optical design optimization, results from numerical ray tracing, mirror-coating choice, and characterization have been described previously [O. V. Gotchev, et al., Rev. Sci. Instrum. 74, 2178 (2003)]. This work highlights the optics' unique mechanical design and flexibility and considers certain applications that benefit from it. Characterization of the microscope's resolution in terms of its modulation transfer function over the field of view is shown. Recent results from hydrodynamic stability experiments, diagnosed with the optic and the PJX, are provided to confirm the microscope's advantages as a high-resolution, high-throughput x-ray optical front end for streaked imaging

  7. Observations of the Perseids 2013 using SPOSH cameras

    Science.gov (United States)

    Margonis, A.; Elgner, S.; Christou, A.; Oberst, J.; Flohrer, J.

    2013-09-01

    Earth is constantly bombard by debris, most of which disintegrates in the upper atmosphere. The collision of a dust particle, having a mass of approximately 1g or larger, with the Earth's atmosphere results into a visible streak of light in the night sky, called meteor. Comets produce new meteoroids each time they come close to the Sun due to sublimation processes. These fresh particles are moving around the Sun in orbits similar to their parent comet forming meteoroid streams. For this reason, the intersection of Earth's orbital path with different comets, gives rise to anumber of meteor showers throughout the year. The Perseids are one of the most prominent annual meteor showers occurring every summer, having its origin in Halley-type comet 109P/Swift-Tuttle. The dense core of this stream passes Earth's orbit on the 12th of August when more than 100 meteors per hour can been seen by a single observer under ideal conditions. The Technical University of Berlin (TUB) and the German Aerospace Center (DLR) together with the Armagh observatory organize meteor campaigns every summer observing the activity of the Perseids meteor shower. The observations are carried out using the Smart Panoramic Optical Sensor Head (SPOSH) camera system [2] which has been developed by DLR and Jena-Optronik GmbH under an ESA/ESTEC contract. The camera was designed to image faint, short-lived phenomena on dark planetary hemispheres. The camera is equipped with a highly sensitive back-illuminated CCD chip having a pixel resolution of 1024x1024. The custom-made fish-eye lens offers a 120°x120° field-of-view (168° over the diagonal) making the monitoring of nearly the whole night sky possible (Fig. 1). This year the observations will take place between 3rd and 10th of August to cover the meteor activity of the Perseids just before their maximum. The SPOSH cameras will be deployed at two remote sites located in high altitudes in the Greek Peloponnese peninsula. The baseline of ∼50km

  8. Absolute calibration method for fast-streaked, fiber optic light collection, spectroscopy systems

    International Nuclear Information System (INIS)

    Johnston, Mark D.; Frogget, Brent; Oliver, Bryan Velten; Maron, Yitzhak; Droemer, Darryl W.; Crain, Marlon D.

    2010-01-01

    This report outlines a convenient method to calibrate fast (<1ns resolution) streaked, fiber optic light collection, spectroscopy systems. Such a system is used to collect spectral data on plasmas generated in the A-K gap of electron beam diodes fielded on the RITS-6 accelerator (8-12MV, 140-200kA). On RITS, light is collected through a small diameter (200 micron) optical fiber and recorded on a fast streak camera at the output of 1 meter Czerny-Turner monochromator (F/7 optics). To calibrate such a system, it is necessary to efficiently couple light from a spectral lamp into a 200 micron diameter fiber, split it into its spectral components, with 10 Angstroms or less resolution, and record it on a streak camera with 1ns or less temporal resolution.

  9. Two-color spatial and temporal temperature measurements using a streaked soft x-ray imager

    Energy Technology Data Exchange (ETDEWEB)

    Moore, A. S., E-mail: alastair.moore@physics.org; Ahmed, M. F.; Soufli, R.; Pardini, T.; Hibbard, R. L.; Bailey, C. G.; Bell, P. M.; Hau-Riege, S. [Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551-0808 (United States); Benstead, J.; Morton, J.; Guymer, T. M.; Garbett, W. J.; Rubery, M. S.; Skidmore, J. W. [Directorate Science and Technology, AWE Aldermaston, Reading RG7 4PR (United Kingdom); Bedzyk, M.; Shoup, M. J.; Regan, S. P.; Agliata, T.; Jungquist, R. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States); Schmidt, D. W. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); and others

    2016-11-15

    A dual-channel streaked soft x-ray imager has been designed and used on high energy-density physics experiments at the National Ignition Facility. This streaked imager creates two images of the same x-ray source using two slit apertures and a single shallow angle reflection from a nickel mirror. Thin filters are used to create narrow band pass images at 510 eV and 360 eV. When measuring a Planckian spectrum, the brightness ratio of the two images can be translated into a color-temperature, provided that the spectral sensitivity of the two images is well known. To reduce uncertainty and remove spectral features in the streak camera photocathode from this photon energy range, a thin 100 nm CsI on 50 nm Al streak camera photocathode was implemented. Provided that the spectral shape is well-known, then uncertainties on the spectral sensitivity limits the accuracy of the temperature measurement to approximately 4.5% at 100 eV.

  10. Large-Grazing-Angle, Multi-Image Kirkpatrick-Baez Microscope as the Front End to a High-Resolution Streak Camera for OMEGA

    International Nuclear Information System (INIS)

    Gotchev, O.V.; Hayes, L.J.; Jaanimagi, P.A.; Knauer, J.P.; Marshall, F.J.; Meyerhofer, D. D.

    2003-01-01

    (B204)A new, high-resolution x-ray microscope with a large grazing angle has been developed, characterized, and fielded at the Laboratory for Laser Energetics. It increases the sensitivity and spatial resolution in planar direct-drive hydrodynamic stability experiments, relevant to inertial confinement fusion (ICF) research. It has been designed to work as the optical front end of the PJX-a high-current, high-dynamic-range x-ray streak camera. Optical design optimization, results from numerical ray tracing, mirror-coating choice, and characterization have been described previously [O. V. Gotchev, et al./Rev. Sci. Instrum. 74, 2178 (2003)]. This work highlights the optics' unique mechanical design and flexibility and considers certain applications that benefit from it. Characterization of the microscope's resolution in terms of its modulation transfer function (MTF) over the field of view is shown. Recent results from hydrodynamic stability experiments, diagnosed with the optic and the PJX, are provided to confirm the microscope's advantages as a high-resolution, high-throughput x-ray optical front end for streaked imaging

  11. Initial tests of the dual-sweep streak camera system planned for APS particle-beam diagnostics

    International Nuclear Information System (INIS)

    Lumpkin, A.; Yang, B.; Gai, W.; Cieslik, W.

    1995-01-01

    Initial tests of a dual-sweep streak system planned for use on the Advanced Photon Source (APS) have been performed using assets of the Argonne Wakefield Accelerator (AWA) facility. The short light pulses from the photoelectric injector drive laser in both the visible (λ=496 nm, Δt∼1.5 ps (FWHM)), and the ultraviolet (λ=248 nm, Δt∼5 ps (FWHM)) were used. Both a UV-visible S20 photocathode streak tube and a UV-to-x-ray Au photocathode streak tube were tested. Calibration data with an etalon were also obtained. A sample of dual-sweep streak data using optical synchrotron radiation on the APS injector synchrotron is also presented

  12. Imacon 600 ultrafast streak camera evaluation

    International Nuclear Information System (INIS)

    Owen, T.C.; Coleman, L.W.

    1975-01-01

    The Imacon 600 has a number of designed in disadvantages for use as an ultrafast diagnostic instrument. The unit is physically large (approximately 5' long) and uses an external power supply rack for the image intensifier. Water cooling is required for the intensifier; it is quiet but not conducive to portability. There is no interlock on the cooling water. The camera does have several switch selectable sweep speeds. This is desirable if one is working with both slow and fast events. The camera can be run in a framing mode. (MOW)

  13. Potential applications of a dual-sweep streak camera system for characterizing particle and photon beams of VUV, XUV, and x-ray FELS

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A. [Argonne National Lab., IL (United States)

    1995-12-31

    The success of time-resolved imaging techniques in the Characterization of particle beams and photon beams of the recent generation of L-band linac-driven or storage ring FELs in the infrared, visible, and ultraviolet wavelength regions can be extended to the VUV, XUV, and x-ray FELs. Tests and initial data have been obtained with the Hamamatsu C5680 dual-sweep streak camera system which includes a demountable photocathode (thin Au) assembly and a flange that allows windowless operation with the transport vacuum system. This system can be employed at wavelengths shorter than 100 nm and down to 1 {Angstrom}. First tests on such a system at 248-nm wavelengths have been performed oil the Argonne Wakefield Accelerator (AWA) drive laser source. A quartz window was used at the tube entrance aperture. A preliminary test using a Be window mounted on a different front flange of the streak tube to look at an x-ray bremsstrahlung source at the AWA was limited by photon statistics. This system`s limiting resolution of {sigma}{approximately}1.1 ps observed at 248 nm would increase with higher incoming photon energies to the photocathode. This effect is related to the fundamental spread in energies of the photoelectrons released from the photocathodes. Possible uses of the synchrotron radiation sources at the Advanced Photon Source and emerging short wavelength FELs to test the system will be presented.

  14. Triton's streaks as windblown dust

    Science.gov (United States)

    Sagan, Carl; Chyba, Christopher

    1990-01-01

    Explanations for the surface streaks observed by Voyager 2 on Triton's southern hemisphere are discussed. It is shown that, despite Triton's tenuous atmosphere, low-cohesion dust trains with diameters of about 5 micron or less may be carried into suspension by aeolian surface shear stress, given expected geostrophic wind speeds of about 10 m/s. For geyser-like erupting dust plumes, it is shown that dust-settling time scales and expected wind velocities can produce streaks with length scales in good agreement with those of the streaks. Thus, both geyserlike eruptions or direct lifting by surface winds appear to be viable mechanisms for the origin of the streaks.

  15. Streaking into middle school science: The Dell Streak pilot project

    Science.gov (United States)

    Austin, Susan Eudy

    A case study is conducted implementing the Dell Streak seven-inch android device into eighth grade science classes of one teacher in a rural middle school in the Piedmont region of North Carolina. The purpose of the study is to determine if the use of the Dell Streaks would increase student achievement on standardized subject testing, if the Streak could be used as an effective instructional tool, and if it could be considered an effective instructional resource for reviewing and preparing for the science assessments. A mixed method research design was used for the study to analyze both quantitative and qualitative results to determine if the Dell Streaks' utilization could achieve the following: 1. instructional strategies would change, 2. it would be an effective instructional tool, and 3. a comparison of the students' test scores and benchmark assessments' scores would provide statistically significant difference. Through the use of an ANOVA it was determined a statistically significant difference had occurred. A Post Hoc analysis was conducted to identify where the difference occurred. Finally a T-test determined was there was no statistically significance difference between the mean End-of-Grade tests and four quarterly benchmark scores of the control and the experimental groups. Qualitative research methods were used to gather results to determine if the Streaks were an effective instructional tool. Classroom observations identified that the teacher's teaching styles and new instructional strategies were implemented throughout the pilot project. Students had an opportunity to complete a questionnaire three times during the pilot project. Results revealed what the students liked about using the devices and the challenges they were facing. The teacher completed a reflective questionnaire throughout the pilot project and offered valuable reflections about the use of the devices in an educational setting. The reflection data supporting the case study was drawn

  16. X-ray streak-camera study of the dynamics of laser-imploded microballoons

    International Nuclear Information System (INIS)

    Key, M.H.; Lamb, M.J.; Lewis, C.L.S.; Moore, A.; Evans, R.G.

    1979-01-01

    The time and space development of the x-ray emission from the irradiated target surface and the implosion core in laser-compressed glass microballoons is recorded by x-ray streak photography. The experimental variation of implosion time with target mass and laser energy is considered and compared with computer modeling of the implosion

  17. Image-converter streak cameras with very high gain

    International Nuclear Information System (INIS)

    1975-01-01

    A new camera is described with slit scanning and very high photonic gain (G=5000). Development of the technology of tubes and microchannel plates has enabled integration of such an amplifying element in an image converter tube which does away with the couplings and the intermediary electron-photon-electron conversions of the classical converter systems having external amplification. It is thus possible to obtain equal or superior performance while retaining considerable gain for the camera, great compactness, great flexibility in use, and easy handling. (author)

  18. Initial Demonstration of 9-MHz Framing Camera Rates on the FAST UV Drive Laser Pulse Trains

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A. H. [Fermilab; Edstrom Jr., D. [Fermilab; Ruan, J. [Fermilab

    2016-10-09

    We report the configuration of a Hamamatsu C5680 streak camera as a framing camera to record transverse spatial information of green-component laser micropulses at 3- and 9-MHz rates for the first time. The latter is near the time scale of the ~7.5-MHz revolution frequency of the Integrable Optics Test Accelerator (IOTA) ring and its expected synchroton radiation source temporal structure. The 2-D images are recorded with a Gig-E readout CCD camera. We also report a first proof of principle with an OTR source using the linac streak camera in a semi-framing mode.

  19. Streaked, x-ray-transmission-grating spectrometer

    International Nuclear Information System (INIS)

    Ceglio, N.M.; Roth, M.; Hawryluk, A.M.

    1981-08-01

    A free standing x-ray transmission grating has been coupled with a soft x-ray streak camera to produce a time resolved x-ray spectrometer. The instrument has a temporal resolution of approx. 20 psec, is capable of covering a broad spectral range, 2 to 120 A, has high sensitivity, and is simple to use requiring no complex alignment procedure. In recent laser fusion experiments the spectrometer successfully recorded time resolved spectra over the range 10 to 120 A with a spectral resolving power, lambda/Δlambda of 4 to 50, limited primarily by source size and collimation effects

  20. Wind Streaks on Earth; Exploration and Interpretation

    Science.gov (United States)

    Cohen-Zada, Aviv Lee; Blumberg, Dan G.; Maman, Shimrit

    2015-04-01

    Wind streaks, one of the most common aeolian features on planetary surfaces, are observable on the surface of the planets Earth, Mars and Venus. Due to their reflectance properties, wind streaks are distinguishable from their surroundings, and they have thus been widely studied by remote sensing since the early 1970s, particularly on Mars. In imagery, these streaks are interpreted as the presence - or lack thereof - of small loose particles on the surface deposited or eroded by wind. The existence of wind streaks serves as evidence for past or present active aeolian processes. Therefore, wind streaks are thought to represent integrative climate processes. As opposed to the comprehensive and global studies of wind streaks on Mars and Venus, wind streaks on Earth are understudied and poorly investigated, both geomorphologically and by remote sensing. The aim of this study is, thus, to fill the knowledge gap about the wind streaks on Earth by: generating a global map of Earth wind streaks from modern high-resolution remotely sensed imagery; incorporating the streaks in a geographic information system (GIS); and overlaying the GIS layers with boundary layer wind data from general circulation models (GCMs) and data from the ECMWF Reanalysis Interim project. The study defines wind streaks (and thereby distinguishes them from other aeolian features) based not only on their appearance in imagery but more importantly on their surface appearance. This effort is complemented by a focused field investigation to study wind streaks on the ground and from a variety of remotely sensed images (both optical and radar). In this way, we provide a better definition of the physical and geomorphic characteristics of wind streaks and acquire a deeper knowledge of terrestrial wind streaks as a means to better understand global and planetary climate and climate change. In a preliminary study, we detected and mapped over 2,900 wind streaks in the desert regions of Earth distributed in

  1. Streak detection and analysis pipeline for space-debris optical images

    Science.gov (United States)

    Virtanen, Jenni; Poikonen, Jonne; Säntti, Tero; Komulainen, Tuomo; Torppa, Johanna; Granvik, Mikael; Muinonen, Karri; Pentikäinen, Hanna; Martikainen, Julia; Näränen, Jyri; Lehti, Jussi; Flohrer, Tim

    2016-04-01

    We describe a novel data-processing and analysis pipeline for optical observations of moving objects, either of natural (asteroids, meteors) or artificial origin (satellites, space debris). The monitoring of the space object populations requires reliable acquisition of observational data, to support the development and validation of population models and to build and maintain catalogues of orbital elements. The orbital catalogues are, in turn, needed for the assessment of close approaches (for asteroids, with the Earth; for satellites, with each other) and for the support of contingency situations or launches. For both types of populations, there is also increasing interest to detect fainter objects corresponding to the small end of the size distribution. The ESA-funded StreakDet (streak detection and astrometric reduction) activity has aimed at formulating and discussing suitable approaches for the detection and astrometric reduction of object trails, or streaks, in optical observations. Our two main focuses are objects in lower altitudes and space-based observations (i.e., high angular velocities), resulting in long (potentially curved) and faint streaks in the optical images. In particular, we concentrate on single-image (as compared to consecutive frames of the same field) and low-SNR detection of objects. Particular attention has been paid to the process of extraction of all necessary information from one image (segmentation), and subsequently, to efficient reduction of the extracted data (classification). We have developed an automated streak detection and processing pipeline and demonstrated its performance with an extensive database of semisynthetic images simulating streak observations both from ground-based and space-based observing platforms. The average processing time per image is about 13 s for a typical 2k-by-2k image. For long streaks (length >100 pixels), primary targets of the pipeline, the detection sensitivity (true positives) is about 90% for

  2. Streak detection and analysis pipeline for optical images

    Science.gov (United States)

    Virtanen, J.; Granvik, M.; Torppa, J.; Muinonen, K.; Poikonen, J.; Lehti, J.; Säntti, T.; Komulainen, T.; Flohrer, T.

    2014-07-01

    We describe a novel data processing and analysis pipeline for optical observations of moving objects, either of natural (asteroids, meteors) or artificial origin (satellites, space debris). The monitoring of the space object populations requires reliable acquisition of observational data to support the development and validation of population models, and to build and maintain catalogues of orbital elements. The orbital catalogues are, in turn, needed for the assessment of close approaches (for asteroids, with the Earth; for satellites, with each other) and for the support of contingency situations or launches. For both types of populations, there is also increasing interest to detect fainter objects corresponding to the small end of the size distribution. We focus on the low signal-to-noise (SNR) detection of objects with high angular velocities, resulting in long and faint object trails, or streaks, in the optical images. The currently available, mature image processing algorithms for detection and astrometric reduction of optical data cover objects that cross the sensor field-of-view comparably slowly, and, particularly for satellites, within a rather narrow, predefined range of angular velocities. By applying specific tracking techniques, the objects appear point-like or as short trails in the exposures. However, the general survey scenario is always a 'track-before-detect' problem, resulting in streaks of arbitrary lengths. Although some considerations for low-SNR processing of streak-like features are available in the current image processing and computer vision literature, algorithms are not readily available yet. In the ESA-funded StreakDet (Streak detection and astrometric reduction) project, we develop and evaluate an automated processing pipeline applicable to single images (as compared to consecutive frames of the same field) obtained with any observing scenario, including space-based surveys and both low- and high-altitude populations. The algorithmic

  3. X-ray streak and framing camera techniques

    International Nuclear Information System (INIS)

    Coleman, L.W.; Attwood, D.T.

    1975-01-01

    This paper reviews recent developments and applications of ultrafast diagnostic techniques for x-ray measurements. These techniques, based on applications of image converter devices, are already capable of significantly important resolution capabilities. Techniques capable of time resolution in the sub-nanosecond regime are being considered. Mechanical cameras are excluded from considerations as are devices using phosphors or fluors as x-ray converters

  4. A new streaked soft x-ray imager for the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Benstead, J., E-mail: james.benstead@awe.co.uk; Morton, J.; Guymer, T. M.; Garbett, W. J.; Rubery, M. S.; Skidmore, J. W. [AWE, Aldermaston, Reading, Berkshire RG7 4PR (United Kingdom); Moore, A. S.; Ahmed, M. F.; Soufli, R.; Pardini, T.; Hibbard, R. L.; Bailey, C. G.; Bell, P. M.; Hau-Riege, S. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Bedzyk, M.; Shoup, M. J.; Reagan, S.; Agliata, T.; Jungquist, R. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States); Schmidt, D. W. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); and others

    2016-05-15

    A new streaked soft x-ray imager has been designed for use on high energy-density (HED) physics experiments at the National Ignition Facility based at the Lawrence Livermore National Laboratory. This streaked imager uses a slit aperture, single shallow angle reflection from a nickel mirror, and soft x-ray filtering to, when coupled to one of the NIF’s x-ray streak cameras, record a 4× magnification, one-dimensional image of an x-ray source with a spatial resolution of less than 90 μm. The energy band pass produced depends upon the filter material used; for the first qualification shots, vanadium and silver-on-titanium filters were used to gate on photon energy ranges of approximately 300–510 eV and 200–400 eV, respectively. A two-channel version of the snout is available for x-ray sources up to 1 mm and a single-channel is available for larger sources up to 3 mm. Both the one and two-channel variants have been qualified on quartz wire and HED physics target shots.

  5. Slope streaks on Mars: A new “wet” mechanism

    Science.gov (United States)

    Kreslavsky, Mikhail A.; Head, James W.

    2009-06-01

    Slope steaks are one of the most intriguing modern phenomena observed on Mars. They have been mostly interpreted as some specific type of granular flow. We propose another mechanism for slope streak formation on Mars. It involves natural seasonal formation of a modest amount of highly concentrated chloride brines within a seasonal thermal skin, and runaway propagation of percolation fronts. Given the current state of knowledge of temperature regimes and the composition and structure of the surface layer in the slope streak regions, this mechanism is consistent with the observational constraints; it requires an assumption that a significant part of the observed chlorine to be in form of calcium and ferric chloride, and a small part of the observed hydrogen to be in form of water ice. This "wet" mechanism has a number of appealing advantages in comparison to the widely accepted "dry" granular flow mechanism. Potential tests for the "wet" mechanism include better modeling of the temperature regime and observations of the seasonality of streak formation.

  6. Automated computer analysis of plasma-streak traces from SCYLLAC

    International Nuclear Information System (INIS)

    Whitman, R.L.; Jahoda, F.C.; Kruger, R.P.

    1977-01-01

    An automated computer analysis technique that locates and references the approximate centroid of single- or dual-streak traces from the Los Alamos Scientific Laboratory SCYLLAC facility is described. The technique also determines the plasma-trace width over a limited self-adjusting region. The plasma traces are recorded with streak cameras on Polaroid film, then scanned and digitized for processing. The analysis technique uses scene segmentation to separate the plasma trace from a reference fiducial trace. The technique employs two methods of peak detection; one for the plasma trace and one for the fiducial trace. The width is obtained using an edge-detection, or slope, method. Timing data are derived from the intensity modulation of the fiducial trace. To smooth (despike) the output graphs showing the plasma-trace centroid and width, a technique of ''twicing'' developed by Tukey was employed. In addition, an interactive sorting algorithm allows retrieval of the centroid, width, and fiducial data from any test shot plasma for post analysis. As yet, only a limited set of sixteen plasma traces has been processed using this technique

  7. Automated computer analysis of plasma-streak traces from SCYLLAC

    International Nuclear Information System (INIS)

    Whiteman, R.L.; Jahoda, F.C.; Kruger, R.P.

    1977-11-01

    An automated computer analysis technique that locates and references the approximate centroid of single- or dual-streak traces from the Los Alamos Scientific Laboratory SCYLLAC facility is described. The technique also determines the plasma-trace width over a limited self-adjusting region. The plasma traces are recorded with streak cameras on Polaroid film, then scanned and digitized for processing. The analysis technique uses scene segmentation to separate the plasma trace from a reference fiducial trace. The technique employs two methods of peak detection; one for the plasma trace and one for the fiducial trace. The width is obtained using an edge-detection, or slope, method. Timing data are derived from the intensity modulation of the fiducial trace. To smooth (despike) the output graphs showing the plasma-trace centroid and width, a technique of ''twicing'' developed by Tukey was employed. In addition, an interactive sorting algorithm allows retrieval of the centroid, width, and fiducial data from any test shot plasma for post analysis. As yet, only a limited set of the plasma traces has been processed with this technique

  8. Betting Decision Under Break-Streak Pattern: Evidence from Casino Gaming.

    Science.gov (United States)

    Fong, Lawrence Hoc Nang; So, Amy Siu Ian; Law, Rob

    2016-03-01

    Cognitive bias is prevalent among gamblers, especially those with gambling problems. Grounded in the heuristics theories, this study contributes to the literature by examining a cognitive bias triggered by the break streak pattern in the casino setting. We postulate that gamblers tend to bet on the latest outcome when there is a break-streak pattern. Moreover, three determinants of the betting decision under break-streak pattern, including the streak length of the alternative outcome, the frequency of the latest outcome, and gender, were identified and examined in this study. A non-participatory observational study was conducted among the Cussec gamblers in a casino in Macao. An analysis of 1229 bets confirms our postulation, particularly when the streak of the alternative outcome is long, the latest outcome is frequent, and the gamblers are females. The findings provide meaningful implications for casino management and public policymakers regarding the minimization of gambling harm.

  9. A cooperative control algorithm for camera based observational systems.

    Energy Technology Data Exchange (ETDEWEB)

    Young, Joseph G.

    2012-01-01

    Over the last several years, there has been considerable growth in camera based observation systems for a variety of safety, scientific, and recreational applications. In order to improve the effectiveness of these systems, we frequently desire the ability to increase the number of observed objects, but solving this problem is not as simple as adding more cameras. Quite often, there are economic or physical restrictions that prevent us from adding additional cameras to the system. As a result, we require methods that coordinate the tracking of objects between multiple cameras in an optimal way. In order to accomplish this goal, we present a new cooperative control algorithm for a camera based observational system. Specifically, we present a receding horizon control where we model the underlying optimal control problem as a mixed integer linear program. The benefit of this design is that we can coordinate the actions between each camera while simultaneously respecting its kinematics. In addition, we further improve the quality of our solution by coupling our algorithm with a Kalman filter. Through this integration, we not only add a predictive component to our control, but we use the uncertainty estimates provided by the filter to encourage the system to periodically observe any outliers in the observed area. This combined approach allows us to intelligently observe the entire region of interest in an effective and thorough manner.

  10. Diving-related visual loss in the setting of angioid streaks: report of two cases.

    Science.gov (United States)

    Angulo Bocco, Maria I; Spielberg, Leigh; Coppens, Greet; Catherine, Janet; Verougstraete, Claire; Leys, Anita M

    2012-01-01

    The purpose of this study was to report diving-related visual loss in the setting of angioid streaks. Observational case reports of two patients with angioid streaks suffering sudden visual loss immediately after diving. Two young adult male patients presented with visual loss after diving headfirst. Funduscopy revealed angioid streaks, peau d'orange, subretinal hemorrhages, and ruptures of Bruch membrane. Choroidal neovascularization developed during follow-up. Both patients had an otherwise uneventful personal and familial medical history. In patients with angioid streaks, diving headfirst can lead to subretinal hemorrhages and traumatic ruptures in Bruch membrane and increase the risk of maculopathy. Ophthalmologists should caution patients with angioid streaks against diving headfirst.

  11. Simultaneous streak and frame interferometry for electron density measurements of laser produced plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Quevedo, H. J., E-mail: hjquevedo@utexas.edu; McCormick, M.; Wisher, M.; Bengtson, Roger D.; Ditmire, T. [Center for High Energy Density Science, Department of Physics, University of Texas at Austin, Austin, Texas 78712 (United States)

    2016-01-15

    A system of two collinear probe beams with different wavelengths and pulse durations was used to capture simultaneously snapshot interferograms and streaked interferograms of laser produced plasmas. The snapshots measured the two dimensional, path-integrated, electron density on a charge-coupled device while the radial temporal evolution of a one dimensional plasma slice was recorded by a streak camera. This dual-probe combination allowed us to select plasmas that were uniform and axisymmetric along the laser direction suitable for retrieving the continuous evolution of the radial electron density of homogeneous plasmas. Demonstration of this double probe system was done by measuring rapidly evolving plasmas on time scales less than 1 ns produced by the interaction of femtosecond, high intensity, laser pulses with argon gas clusters. Experiments aimed at studying homogeneous plasmas from high intensity laser-gas or laser-cluster interaction could benefit from the use of this probing scheme.

  12. Observations of the Perseids 2012 using SPOSH cameras

    Science.gov (United States)

    Margonis, A.; Flohrer, J.; Christou, A.; Elgner, S.; Oberst, J.

    2012-09-01

    The Perseids are one of the most prominent annual meteor showers occurring every summer when the stream of dust particles, originating from Halley-type comet 109P/Swift-Tuttle, intersects the orbital path of the Earth. The dense core of this stream passes Earth's orbit on the 12th of August producing the maximum number of meteors. The Technical University of Berlin (TUB) and the German Aerospace Center (DLR) organize observing campaigns every summer monitoring the Perseids activity. The observations are carried out using the Smart Panoramic Optical Sensor Head (SPOSH) camera system [0]. The SPOSH camera has been developed by DLR and Jena-Optronik GmbH under an ESA/ESTEC contract and it is designed to image faint, short-lived phenomena on dark planetary hemispheres. The camera features a highly sensitive backilluminated 1024x1024 CCD chip and a high dynamic range of 14 bits. The custom-made fish-eye lens offers a 120°x120° field-of-view (168° over the diagonal). Figure 1: A meteor captured by the SPOSH cameras simultaneously during the last 2011 observing campaign in Greece. The horizon including surrounding mountains can be seen in the image corners as a result of the large FOV of the camera. The observations will be made on the Greek Peloponnese peninsula monitoring the post-peak activity of the Perseids during a one-week period around the August New Moon (14th to 21st). Two SPOSH cameras will be deployed in two remote sites in high altitudes for the triangulation of meteor trajectories captured at both stations simultaneously. The observations during this time interval will give us the possibility to study the poorly-observed postmaximum branch of the Perseid stream and compare the results with datasets from previous campaigns which covered different periods of this long-lived meteor shower. The acquired data will be processed using dedicated software for meteor data reduction developed at TUB and DLR. Assuming a successful campaign, statistics, trajectories

  13. Nonlinear streak computation using boundary region equations

    Energy Technology Data Exchange (ETDEWEB)

    Martin, J A; Martel, C, E-mail: juanangel.martin@upm.es, E-mail: carlos.martel@upm.es [Depto. de Fundamentos Matematicos, E.T.S.I Aeronauticos, Universidad Politecnica de Madrid, Plaza Cardenal Cisneros 3, 28040 Madrid (Spain)

    2012-08-01

    The boundary region equations (BREs) are applied for the simulation of the nonlinear evolution of a spanwise periodic array of streaks in a flat plate boundary layer. The well-known BRE formulation is obtained from the complete Navier-Stokes equations in the high Reynolds number limit, and provides the correct asymptotic description of three-dimensional boundary layer streaks. In this paper, a fast and robust streamwise marching scheme is introduced to perform their numerical integration. Typical streak computations present in the literature correspond to linear streaks or to small-amplitude nonlinear streaks computed using direct numerical simulation (DNS) or the nonlinear parabolized stability equations (PSEs). We use the BREs to numerically compute high-amplitude streaks, a method which requires much lower computational effort than DNS and does not have the consistency and convergence problems of the PSE. It is found that the flow configuration changes substantially as the amplitude of the streaks grows and the nonlinear effects come into play. The transversal motion (in the wall normal-streamwise plane) becomes more important and strongly distorts the streamwise velocity profiles, which end up being quite different from those of the linear case. We analyze in detail the resulting flow patterns for the nonlinearly saturated streaks and compare them with available experimental results. (paper)

  14. 100ps UV/x-ray framing camera

    International Nuclear Information System (INIS)

    Eagles, R.T.; Freeman, N.J.; Allison, J.M.; Sibbett, W.; Sleat, W.E.; Walker, D.R.

    1988-01-01

    The requirement for a sensitive two-dimensional imaging diagnostic with picosecond time resolution, particularly in the study of laser-produced plasmas, has previously been discussed. A temporal sequence of framed images would provide useful supplementary information to that provided by time resolved streak images across a spectral region of interest from visible to x-ray. To fulfill this requirement the Picoframe camera system has been developed. Results pertaining to the operation of a camera having S20 photocathode sensitivity are reviewed and the characteristics of an UV/x-ray sensitive version of the Picoframe system are presented

  15. The origin and structure of streak-like instabilities in laminar boundary layer flames

    Science.gov (United States)

    Gollner, Michael; Miller, Colin; Tang, Wei; Finney, Mark

    2017-11-01

    Streamwise streaks are consistently observed in wildland fires, at the base of pool fires, and in other heated flows within a boundary layer. This study examines both the origin of these structures and their role in influencing some of the macroscopic properties of the flow. Streaks were reproduced and characterized via experiments on stationary heated strips and liquid and gas-fueled burners in laminar boundary layer flows, providing a framework to develop theory based on both observed and measured physical phenomena. The incoming boundary layer was established as the controlling mechanism in forming streaks, which are generated by pre-existing coherent structures, while the amplification of streaks was determined to be compatible with quadratic growth of Rayleigh-Taylor Instabilities, providing credence to the idea that the downstream growth of streaks is strongly tied to buoyancy. These local instabilities were also found to affect macroscopic properties of the flow, including heat transfer to the surface, indicating that a two-dimensional assumption may fail to adequately describe heat and mass transfer during flame spread and other reacting boundary layer flows. This work was supported by NSF (CBET-1554026) and the USDA-FS (13-CS-11221637-124).

  16. Ultra-fast framing camera tube

    Science.gov (United States)

    Kalibjian, Ralph

    1981-01-01

    An electronic framing camera tube features focal plane image dissection and synchronized restoration of the dissected electron line images to form two-dimensional framed images. Ultra-fast framing is performed by first streaking a two-dimensional electron image across a narrow slit, thereby dissecting the two-dimensional electron image into sequential electron line images. The dissected electron line images are then restored into a framed image by a restorer deflector operated synchronously with the dissector deflector. The number of framed images on the tube's viewing screen is equal to the number of dissecting slits in the tube. The distinguishing features of this ultra-fast framing camera tube are the focal plane dissecting slits, and the synchronously-operated restorer deflector which restores the dissected electron line images into a two-dimensional framed image. The framing camera tube can produce image frames having high spatial resolution of optical events in the sub-100 picosecond range.

  17. Medium-sized aperture camera for Earth observation

    Science.gov (United States)

    Kim, Eugene D.; Choi, Young-Wan; Kang, Myung-Seok; Kim, Ee-Eul; Yang, Ho-Soon; Rasheed, Ad. Aziz Ad.; Arshad, Ahmad Sabirin

    2017-11-01

    Satrec Initiative and ATSB have been developing a medium-sized aperture camera (MAC) for an earth observation payload on a small satellite. Developed as a push-broom type high-resolution camera, the camera has one panchromatic and four multispectral channels. The panchromatic channel has 2.5m, and multispectral channels have 5m of ground sampling distances at a nominal altitude of 685km. The 300mm-aperture Cassegrain telescope contains two aspheric mirrors and two spherical correction lenses. With a philosophy of building a simple and cost-effective camera, the mirrors incorporate no light-weighting, and the linear CCDs are mounted on a single PCB with no beam splitters. MAC is the main payload of RazakSAT to be launched in 2005. RazakSAT is a 180kg satellite including MAC, designed to provide high-resolution imagery of 20km swath width on a near equatorial orbit (NEqO). The mission objective is to demonstrate the capability of a high-resolution remote sensing satellite system on a near equatorial orbit. This paper describes the overview of the MAC and RarakSAT programmes, and presents the current development status of MAC focusing on key optical aspects of Qualification Model.

  18. Initial Observations of Micropulse Elongation of Electron Beams in a SCRF Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A. H. [Fermilab; Thurman-Keup, R. [Fermilab; Edstrom Jr., D. [Fermilab; Ruan, J. [Fermilab; Santucci, J. [Fermilab

    2016-10-09

    Commissioning at the SCRF accelerator at the Fermilab Accelerator Science and Technology (FAST) Facility has included the implementation of a versatile bunch-length monitor located after the 4-dipole chicane bunch compressor for electron beam energies of 20-50 MeV and integrated charges in excess of 10 nC. The team has initially used a Hamamatsu C5680 synchroscan streak camera to assess the effects of space charge on the electron beam bunch lengths. An Al-coated Si screen was used to generate optical transition radiation (OTR) resulting from the beam’s interaction with the screen. The chicane bypass beamline allowed the measurements of the bunch length without the compression stage at the downstream beamline location using OTR and the streak camera. We have observed electron beam bunch lengths from 5 to 16 ps (sigma) for micropulse charges of 60 pC to 800 pC, respectively. We also report a compressed sub-ps micropulse case.

  19. MULTIMODAL IMAGING OF ANGIOID STREAKS ASSOCIATED WITH TURNER SYNDROME.

    Science.gov (United States)

    Chiu, Bing Q; Tsui, Edmund; Hussnain, Syed Amal; Barbazetto, Irene A; Smith, R Theodore

    2018-02-13

    To report multimodal imaging in a novel case of angioid streaks in a patient with Turner syndrome with 10-year follow-up. Case report of a patient with Turner syndrome and angioid streaks followed at Bellevue Hospital Eye Clinic from 2007 to 2017. Fundus photography, fluorescein angiography, and optical coherence tomography angiography were obtained. Angioid streaks with choroidal neovascularization were noted in this patient with Turner syndrome without other systemic conditions previously correlated with angioid streaks. We report a case of angioid streaks with choroidal neovascularization in a patient with Turner syndrome. We demonstrate that angioid streaks, previously associated with pseudoxanthoma elasticum, Ehlers-Danlos syndrome, Paget disease of bone, and hemoglobinopathies, may also be associated with Turner syndrome, and may continue to develop choroidal neovascularization, suggesting the need for careful ophthalmic examination in these patients.

  20. A numerical algorithm to evaluate the transient response for a synchronous scanning streak camera using a time-domain Baum–Liu–Tesche equation

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Chengquan [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); Tian, Jinshou [Xi' an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); Wu, Shengli, E-mail: slwu@mail.xjtu.edu.cn [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); He, Jiai [School of Computer and Communication, Lanzhou University of Technology, Lanzhou, Gansu 730050 (China); Liu, Zhen [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China)

    2016-10-01

    The transient response is of great influence on the electromagnetic compatibility of synchronous scanning streak cameras (SSSCs). In this paper we propose a numerical method to evaluate the transient response of the scanning deflection plate (SDP). First, we created a simplified circuit model for the SDP used in an SSSC, and then derived the Baum–Liu–Tesche (BLT) equation in the frequency domain. From the frequency-domain BLT equation, its transient counterpart was derived. These parameters, together with the transient-BLT equation, were used to compute the transient load voltage and load current, and then a novel numerical method to fulfill the continuity equation was used. Several numerical simulations were conducted to verify this proposed method. The computed results were then compared with transient responses obtained by a frequency-domain/fast Fourier transform (FFT) method, and the accordance was excellent for highly conducting cables. The benefit of deriving the BLT equation in the time domain is that it may be used with slight modifications to calculate the transient response and the error can be controlled by a computer program. The result showed that the transient voltage was up to 1000 V and the transient current was approximately 10 A, so some protective measures should be taken to improve the electromagnetic compatibility.

  1. A numerical algorithm to evaluate the transient response for a synchronous scanning streak camera using a time-domain Baum–Liu–Tesche equation

    International Nuclear Information System (INIS)

    Pei, Chengquan; Tian, Jinshou; Wu, Shengli; He, Jiai; Liu, Zhen

    2016-01-01

    The transient response is of great influence on the electromagnetic compatibility of synchronous scanning streak cameras (SSSCs). In this paper we propose a numerical method to evaluate the transient response of the scanning deflection plate (SDP). First, we created a simplified circuit model for the SDP used in an SSSC, and then derived the Baum–Liu–Tesche (BLT) equation in the frequency domain. From the frequency-domain BLT equation, its transient counterpart was derived. These parameters, together with the transient-BLT equation, were used to compute the transient load voltage and load current, and then a novel numerical method to fulfill the continuity equation was used. Several numerical simulations were conducted to verify this proposed method. The computed results were then compared with transient responses obtained by a frequency-domain/fast Fourier transform (FFT) method, and the accordance was excellent for highly conducting cables. The benefit of deriving the BLT equation in the time domain is that it may be used with slight modifications to calculate the transient response and the error can be controlled by a computer program. The result showed that the transient voltage was up to 1000 V and the transient current was approximately 10 A, so some protective measures should be taken to improve the electromagnetic compatibility.

  2. Genetic Analysis of Streaked and Abnormal Floret Mutant st-fon

    Directory of Open Access Journals (Sweden)

    De-xi CHEN

    2013-07-01

    Full Text Available A double mutant with streaked leaf and abnormal floret was found and temporarily named streaked leaf and floral organ number mutant (st-fon. For this mutant, besides white streak appeared on culm, leaves and panicles, the number of floral organs increased and florets cracked. The extreme phenotype was that several small florets grew from one floret or branch rachis in small florets extended and developed into panicles. By using transmission electron microscope to observe the ultrastructure of white histocytes of leaves at the seedling stage, the white tissues which showed abnormal plastids, lamellas and thylakoids could not develop into normal chloroplast, and the development of chloroplast was blocked at the early growth stage of plastid. Scanning electron microscope and paraffin section were also used to observe the development of floral organs, and the results indicated that the development of floral meristem was out of order and unlimited, whereas in the twisty leaves, vascular bundle sheath cells grew excessively, or some bubbly cells increased. Genetic analyses carried out by means of cross and backcross with four normal-leaf-color materials revealed that the mutant is of cytoplasm inheritance.

  3. Observation of runaway electrons by infrared camera in J-TEXT

    Energy Technology Data Exchange (ETDEWEB)

    Tong, R. H.; Chen, Z. Y., E-mail: zychen@hust.edu.cn; Zhang, M.; Huang, D. W.; Yan, W.; Zhuang, G. [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2016-11-15

    When the energy of confined runaway electrons approaches several tens of MeV, the runaway electrons can emit synchrotron radiation in the range of infrared wavelength. An infrared camera working in the wavelength of 3-5 μm has been developed to study the runaway electrons in the Joint Texas Experimental Tokamak (J-TEXT). The camera is located in the equatorial plane looking tangentially into the direction of electron approach. The runaway electron beam inside the plasma has been observed at the flattop phase. With a fast acquisition of the camera, the behavior of runaway electron beam has been observed directly during the runaway current plateau following the massive gas injection triggered disruptions.

  4. Development of a visible framing camera diagnostic for the study of current initiation in z-pinch plasmas

    International Nuclear Information System (INIS)

    Muron, D.J.; Hurst, M.J.; Derzon, M.S.

    1996-01-01

    The authors assembled and tested a visible framing camera system to take 5 ns FWHM images of the early time emission from a z-pinch plasma. This diagnostic was used in conjunction with a visible streak camera allowing early time emissions measurements to diagnose current initiation. Individual frames from gated image intensifiers were proximity coupled to charge injection device (CID) cameras and read out at video rate and 8-bit resolution. A mirror was used to view the pinch from a 90-degree angle. The authors observed the destruction of the mirror surface, due to the high surface heating, and the subsequent reduction in signal reflected from the mirror. Images were obtained that showed early time ejecta and a nonuniform emission from the target. This initial test of the equipment highlighted problems with this measurement. They observed non-uniformities in early time emission. This is believed to be due to either spatially varying current density or heating of the foam. Images were obtained that showed early time ejecta from the target. The results and suggestions for improvement are discussed in the text

  5. Streaking tremor in Cascadia

    Science.gov (United States)

    Vidale, J. E.; Ghosh, A.; Sweet, J. R.; Creager, K. C.; Wech, A.; Houston, H.

    2009-12-01

    Details of tremor deep in subduction zones is damnably difficult to glimpse because of the lack of crisp initial arrivals, low waveform coherence, uncertain focal mechanisms, and the probability of simultaneous activity across extended regions. Yet such details hold out the best hope to illuminate the unknown mechanisms underlying episodic tremor and slip. Attacking this problem with brute force, we pointed a small, very dense seismic array down at the migration path of a good-sized episodic tremor and slip (ETS) event. In detail, it was an 84-element, 1300-m-aperture temporary seismic array in northern Washington, and the migration path of the May 2008 ETS event was 30-40 km directly underneath. Our beamforming technique tracked the time, incident angle, and azimuth of tremor radiation in unprecedented detail. We located the tremor by assuming it occurs on the subduction interface, estimated relative tremor moment released by each detected tremor window, and mapped it on the interface [Ghosh et al., GRL, 2009]. Fortunately for our ability to image it, the tremor generally appears to emanate from small regions, and we were surprised by how steadily the regions migrated with time. For the first time in Cascadia, we found convergence-parallel transient streaks of tremor migrating at velocities of several tens of km/hr, with movement in both up- and down-dip directions. Similar patterns have been seen in Japan [Shelly, G3, 2007]. This is in contrast to the long-term along-strike marching of tremor at 10 km/day. These streaks tend to propagate steadily and often repeat the same track on the interface multiple times. They light up persistent moment patches on the interface by a combination of increased amplitude and longer residence time within the patches. The up- and down-dip migration dominates the 2 days of tremor most clearly imaged by our array. The tendency of the streaks to fill in bands is the subject of the presentation of Ghosh et al. here. The physical

  6. A compact large-format streak tube for imaging lidar

    Science.gov (United States)

    Hui, Dandan; Luo, Duan; Tian, Liping; Lu, Yu; Chen, Ping; Wang, Junfeng; Sai, Xiaofeng; Wen, Wenlong; Wang, Xing; Xin, Liwei; Zhao, Wei; Tian, Jinshou

    2018-04-01

    The streak tubes with a large effective photocathode area, large effective phosphor screen area, and high photocathode radiant sensitivity are essential for improving the field of view, depth of field, and detectable range of the multiple-slit streak tube imaging lidar. In this paper, a high spatial resolution, large photocathode area, and compact meshless streak tube with a spherically curved cathode and screen is designed and tested. Its spatial resolution reaches 20 lp/mm over the entire Φ28 mm photocathode working area, and the simulated physical temporal resolution is better than 30 ps. The temporal distortion in our large-format streak tube, which is shown to be a non-negligible factor, has a minimum value as the radius of curvature of the photocathode varies. Furthermore, the photocathode radiant sensitivity and radiant power gain reach 41 mA/W and 18.4 at the wavelength of 550 nm, respectively. Most importantly, the external dimensions of our streak tube are no more than Φ60 mm × 110 mm.

  7. An evaluation of video cameras for collecting observational data on sanctuary-housed chimpanzees (Pan troglodytes).

    Science.gov (United States)

    Hansen, Bethany K; Fultz, Amy L; Hopper, Lydia M; Ross, Stephen R

    2018-05-01

    Video cameras are increasingly being used to monitor captive animals in zoo, laboratory, and agricultural settings. This technology may also be useful in sanctuaries with large and/or complex enclosures. However, the cost of camera equipment and a lack of formal evaluations regarding the use of cameras in sanctuary settings make it challenging for facilities to decide whether and how to implement this technology. To address this, we evaluated the feasibility of using a video camera system to monitor chimpanzees at Chimp Haven. We viewed a group of resident chimpanzees in a large forested enclosure and compared observations collected in person and with remote video cameras. We found that via camera, the observer viewed fewer chimpanzees in some outdoor locations (GLMM post hoc test: est. = 1.4503, SE = 0.1457, Z = 9.951, p sanctuaries to facilitate animal care and observational research. © 2018 Wiley Periodicals, Inc.

  8. Development of a Data Reduction Algorithm for Optical Wide Field Patrol (OWL) II: Improving Measurement of Lengths of Detected Streaks

    Science.gov (United States)

    Park, Sun-Youp; Choi, Jin; Roh, Dong-Goo; Park, Maru; Jo, Jung Hyun; Yim, Hong-Suh; Park, Young-Sik; Bae, Young-Ho; Park, Jang-Hyun; Moon, Hong-Kyu; Choi, Young-Jun; Cho, Sungki; Choi, Eun-Jung

    2016-09-01

    As described in the previous paper (Park et al. 2013), the detector subsystem of optical wide-field patrol (OWL) provides many observational data points of a single artificial satellite or space debris in the form of small streaks, using a chopper system and a time tagger. The position and the corresponding time data are matched assuming that the length of a streak on the CCD frame is proportional to the time duration of the exposure during which the chopper blades do not obscure the CCD window. In the previous study, however, the length was measured using the diagonal of the rectangle of the image area containing the streak; the results were quite ambiguous and inaccurate, allowing possible matching error of positions and time data. Furthermore, because only one (position, time) data point is created from one streak, the efficiency of the observation decreases. To define the length of a streak correctly, it is important to locate the endpoints of a streak. In this paper, a method using a differential convolution mask pattern is tested. This method can be used to obtain the positions where the pixel values are changed sharply. These endpoints can be regarded as directly detected positional data, and the number of data points is doubled by this result.

  9. Transition due to streamwise streaks in a supersonic flat plate boundary layer

    Science.gov (United States)

    Paredes, Pedro; Choudhari, Meelan M.; Li, Fei

    2016-12-01

    Transition induced by stationary streaks undergoing transient growth in a supersonic flat plate boundary layer flow is studied using numerical computations. While the possibility of strong transient growth of small-amplitude stationary perturbations in supersonic boundary layer flows has been demonstrated in previous works, its relation to laminar-turbulent transition cannot be established within the framework of linear disturbances. Therefore, this paper investigates the nonlinear evolution of initially linear optimal disturbances that evolve into finite amplitude streaks in the downstream region, and then studies the modal instability of those streaks as a likely cause for the onset of bypass transition. The nonmodal evolution of linearly optimal stationary perturbations in a supersonic, Mach 3 flat plate boundary layer is computed via the nonlinear plane-marching parabolized stability equations (PSE) for stationary perturbations, or equivalently, the perturbation form of parabolized Navier-Stokes equations. To assess the effect of the nonlinear finite-amplitude streaks on transition, the linear form of plane-marching PSE is used to investigate the instability of the boundary layer flow modified by the spanwise periodic streaks. The onset of transition is estimated using an N -factor criterion based on modal amplification of the secondary instabilities of the streaks. In the absence of transient growth disturbances, first mode instabilities in a Mach 3, zero pressure gradient boundary layer reach N =10 at Rex≈107 . However, secondary instability modes of the stationary streaks undergoing transient growth are able to achieve the same N -factor at Rex<2 ×106 when the initial streak amplitude is sufficiently large. In contrast to the streak instabilities in incompressible flows, subharmonic instability modes with twice the fundamental spanwise wavelength of the streaks are found to have higher amplification ratios than the streak instabilities at fundamental

  10. Weather and atmosphere observation with the ATOM all-sky camera

    Directory of Open Access Journals (Sweden)

    Jankowsky Felix

    2015-01-01

    Full Text Available The Automatic Telescope for Optical Monitoring (ATOM for H.E.S.S. is an 75 cm optical telescope which operates fully automated. As there is no observer present during observation, an auxiliary all-sky camera serves as weather monitoring system. This device takes an all-sky image of the whole sky every three minutes. The gathered data then undergoes live-analysis by performing astrometric comparison with a theoretical night sky model, interpreting the absence of stars as cloud coverage. The sky monitor also serves as tool for a meteorological analysis of the observation site of the the upcoming Cherenkov Telescope Array. This overview covers design and benefits of the all-sky camera and additionally gives an introduction into current efforts to integrate the device into the atmosphere analysis programme of H.E.S.S.

  11. Orientation tuning of contrast masking caused by motion streaks.

    Science.gov (United States)

    Apthorp, Deborah; Cass, John; Alais, David

    2010-08-01

    We investigated whether the oriented trails of blur left by fast-moving dots (i.e., "motion streaks") effectively mask grating targets. Using a classic overlay masking paradigm, we varied mask contrast and target orientation to reveal underlying tuning. Fast-moving Gaussian blob arrays elevated thresholds for detection of static gratings, both monoptically and dichoptically. Monoptic masking at high mask (i.e., streak) contrasts is tuned for orientation and exhibits a similar bandwidth to masking functions obtained with grating stimuli (∼30 degrees). Dichoptic masking fails to show reliable orientation-tuned masking, but dichoptic masks at very low contrast produce a narrowly tuned facilitation (∼17 degrees). For iso-oriented streak masks and grating targets, we also explored masking as a function of mask contrast. Interestingly, dichoptic masking shows a classic "dipper"-like TVC function, whereas monoptic masking shows no dip and a steeper "handle". There is a very strong unoriented component to the masking, which we attribute to transiently biased temporal frequency masking. Fourier analysis of "motion streak" images shows interesting differences between dichoptic and monoptic functions and the information in the stimulus. Our data add weight to the growing body of evidence that the oriented blur of motion streaks contributes to the processing of fast motion signals.

  12. Angioid streaks, clinical course, complications, and current therapeutic management

    Directory of Open Access Journals (Sweden)

    Ilias Georgalas

    2008-12-01

    Full Text Available Ilias Georgalas1, Dimitris Papaconstantinou2, Chrysanthi Koutsandrea2, George Kalantzis2, Dimitris Karagiannis2, Gerasimos Georgopoulos2, Ioannis Ladas21Department of Ophthalmology, “G. Gennimatas” Hospital of Athens, NHS, Athens, Greece; 2Department of Ophthalmology, “G. Gennimatas” Hospital of Athens, University of Athens, Athens, GreeceAbstract: Angioid streaks are visible irregular crack-like dehiscences in Bruch’s membrane that are associated with atrophic degeneration of the overlying retinal pigmented epithelium. Angioid streaks may be associated with pseudoxanthoma elasticum, Paget’s disease, sickle-cell anemia, acromegaly, Ehlers–Danlos syndrome, and diabetes mellitus, but also appear in patients without any systemic disease. Patients with angioid streaks are generally asymptomatic, unless the lesions extend towards the foveola or develop complications such as traumatic Bruch’s membrane rupture or macular choroidal neovascularization (CNV. The visual prognosis in patients with CNV secondary to angioid streaks if untreated, is poor and most treatment modalities, until recently, have failed to limit the devastating impact of CNV in central vision. However, it is likely that treatment with antivascular endothelial growth factor, especially in treatment-naive eyes to yield favorable results in the future and this has to be investigated in future studies.Keywords: angioid streaks, pseudoxanthoma elasticum, choroidal neovascularization

  13. Earth aeolian wind streaks: Comparison to wind data from model and stations

    Science.gov (United States)

    Cohen-Zada, A. L.; Maman, S.; Blumberg, D. G.

    2017-05-01

    Wind streak is a collective term for a variety of aeolian features that display distinctive albedo surface patterns. Wind streaks have been used to map near-surface winds and to estimate atmospheric circulation patterns on Mars and Venus. However, because wind streaks have been studied mostly on Mars and Venus, much of the knowledge regarding the mechanism and time frame of their formation and their relationship to the atmospheric circulation cannot be verified. This study aims to validate previous studies' results by a comparison of real and modeled wind data with wind streak orientations as measured from remote-sensing images. Orientations of Earth wind streaks were statistically correlated to resultant drift direction (RDD) values calculated from reanalysis and wind data from 621 weather stations. The results showed good agreement between wind streak orientations and reanalysis RDD (r = 0.78). A moderate correlation was found between the wind streak orientations and the weather station data (r = 0.47); a similar trend was revealed on a regional scale when the analysis was performed by continent, with r ranging from 0.641 in North America to 0.922 in Antarctica. At sites where wind streak orientations did not correspond to the RDDs (i.e., a difference of 45°), seasonal and diurnal variations in the wind flow were found to be responsible for deviation from the global pattern. The study thus confirms that Earth wind streaks were formed by the present wind regime and they are indeed indicative of the long-term prevailing wind direction on global and regional scales.

  14. Approaches to diagnosis and detection of cassava brown streak ...

    African Journals Online (AJOL)

    Cassava brown streak disease (CBSD) has been a problem in the East African coastal cassava growing areas for more than 70 years. The disease is caused by successful infection with Cassava Brown Streak Virus (CBSV) (Family, Potyviridae: Genus, Ipomovirus). Diagnosis of CBSD has for long been primarily leaf ...

  15. Postprocessing method to clean up streaks due to noisy detectors

    International Nuclear Information System (INIS)

    Tuy, H.K.; Mattson, R.A.

    1990-01-01

    This paper reports that occasionally, one of the thousands of detectors in a CT scanner will intermittently produce erroneous data, creating streaks in the reconstructed image. The authors propose a method to identify and clean up the streaks automatically. To find the rays along which the data values are bad, a binary image registering the edges of the original image is created. Forward projection is applied to the binary image to single out edges along rays. Data along views containing the identified bad rays are estimated by means of forward projecting the original image. Back projection of the negative of the estimated convolved data along these views onto the streaky image will remove streaks from the image. Image enhancement is achieved by means of back projecting the convolved data estimated from the image after the streak removal along views of bad rays

  16. Control of Vascular Streak Dieback Disease of Cocoa with Flutriafol Fungicides

    Directory of Open Access Journals (Sweden)

    Febrilia Nur'aini

    2014-12-01

    Full Text Available Vascular streak dieback caused by the fungus Oncobasidium theobromae is one of the important diseases in cocoa crop in Indonesia. One approach to control the disease is by using fungicides. The aim of this research was to determine the effect of class triazole fungicides to the intensity of the vascular streak dieback disease on cocoa seedling phase, immature and mature cocoa. Experiments were conducted in Kotta Blater, PTPN XII and Kaliwining, Indonesian  Coffee and Cocoa Research Institute. Flutriafol 250 g/l with a concentration 0,05%, 0,1% and 0,15% foliar sprayed on cocoa seedlings, immature and mature cocoa. Active compound combination of Azoxystrobin and Difenoconazole with 0,1% concentration used as a comparation fungicides. The result showed that Flutriafol with 0,05%, 0,1% and 0,15% concentration and Azoxystrobin & Difenoconazol with 0,1% concentration could suppress the vascular streak dieback disease on seedlings. On immature plants, the application of Flutriafol was not effectively suppress the vascular streak dieback disease whereas the fungicide comparison could suppress with the efficacy level of 46.22%. On mature plants,both of fungicides could not suppress the vascular streak dieback disease. Key words: Fungicide, cocoa, vascular streak dieback, triazole, flutriafol, azoxystrobin+difenoconazol

  17. Laparoscopic Removal of Streak Gonads in Turner Syndrome.

    Science.gov (United States)

    Mandelberger, Adrienne; Mathews, Shyama; Andikyan, Vaagn; Chuang, Linus

    To demonstrate the skills necessary for complete resection of bilateral streak gonads in Turner syndrome. Video case presentation with narration highlighting the key techniques used. The video was deemed exempt from formal review by our institutional review board. Turner syndrome is a form of gonadal dysgenesis that affects 1 in 2500 live births. Patients often have streak gonads and may present with primary amenorrhea or premature ovarian failure. Patients with a mosaic karyotype that includes a Y chromosome are at increased risk for gonadoblastoma and subsequent transformation into malignancy. Gonadectomy is recommended for these patients, typically at adolescence. Streak gonads can be difficult to identify, and tissue margins are often in close proximity to critical retroperitoneal structures. Resection can be technically challenging and requires a thorough understanding of retroperitoneal anatomy and precise dissection techniques to ensure complete removal. Laparoscopic approach to bilateral salpingo-oophorectomy of streak gonads. Retroperitoneal dissection and ureterolysis are performed, with the aid of the Ethicon Harmonic Ace, to ensure complete gonadectomy. Careful and complete resection of gonadal tissue in the hands of a skilled laparoscopic surgeon is key for effective cancer risk reduction surgery in Turner syndrome mosaics. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  18. Picosecond Streaked K-Shell Spectroscopy of Near Solid-Density Aluminum Plasmas

    Science.gov (United States)

    Stillman, C. R.; Nilson, P. M.; Ivancic, S. T.; Mileham, C.; Froula, D. H.; Golovkin, I. E.

    2016-10-01

    The thermal x-ray emission from rapidly heated solid targets containing a buried-aluminum layer was measured. The targets were driven by high-contrast 1 ω or 2 ω laser pulses at focused intensities up to 1 ×1019W/Wcm2 cm2 . A streaked x-ray spectrometer recorded the Al Heα and lithium-like satellite lines with 2-ps temporal resolution and moderate resolving power (E/E ΔE 700). Time-integrated measurements over the same spectral range were used to correct the streaked data for variations in photocathode sensitivity. Line widths and intensity ratios from the streaked data were interpreted using a collisional radiative atomic model to provide the average plasma conditions in the buried layer as a function of time. It was observed that the resonance line tends toward lower photon energies at high electron densities. The measured shifts will be compared to predicted shifts from Stark-operator calculations at the inferred plasma conditions. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944, the office of Fusion Energy Sciences Award Number DE-SC0012317, and the Stewardship Science Graduate Fellowship Grant Number DE-NA0002135.

  19. Stabilization of the hypersonic boundary layer by finite-amplitude streaks

    Science.gov (United States)

    Ren, Jie; Fu, Song; Hanifi, Ardeshir

    2016-02-01

    Stabilization of two-dimensional disturbances in hypersonic boundary layer flows by finite-amplitude streaks is investigated using nonlinear parabolized stability equations. The boundary-layer flows at Mach numbers 4.5 and 6.0 are studied in which both first and second modes are supported. The streaks considered here are driven either by the so-called optimal perturbations (Klebanoff-type) or the centrifugal instability (Görtler-type). When the streak amplitude is in an appropriate range, i.e., large enough to modulate the laminar boundary layer but low enough to not trigger secondary instability, both first and second modes can effectively be suppressed.

  20. Networked web-cameras monitor congruent seasonal development of birches with phenological field observations

    Science.gov (United States)

    Peltoniemi, Mikko; Aurela, Mika; Böttcher, Kristin; Kolari, Pasi; Loehr, John; Karhu, Jouni; Kubin, Eero; Linkosalmi, Maiju; Melih Tanis, Cemal; Nadir Arslan, Ali

    2017-04-01

    Ecosystems' potential to provide services, e.g. to sequester carbon is largely driven by the phenological cycle of vegetation. Timing of phenological events is required for understanding and predicting the influence of climate change on ecosystems and to support various analyses of ecosystem functioning. We established a network of cameras for automated monitoring of phenological activity of vegetation in boreal ecosystems of Finland. Cameras were mounted on 14 sites, each site having 1-3 cameras. In this study, we used cameras at 11 of these sites to investigate how well networked cameras detect phenological development of birches (Betula spp.) along the latitudinal gradient. Birches are interesting focal species for the analyses as they are common throughout Finland. In our cameras they often appear in smaller quantities within dominant species in the images. Here, we tested whether small scattered birch image elements allow reliable extraction of color indices and changes therein. We compared automatically derived phenological dates from these birch image elements to visually determined dates from the same image time series, and to independent observations recorded in the phenological monitoring network from the same region. Automatically extracted season start dates based on the change of green color fraction in the spring corresponded well with the visually interpreted start of season, and field observed budburst dates. During the declining season, red color fraction turned out to be superior over green color based indices in predicting leaf yellowing and fall. The latitudinal gradients derived using automated phenological date extraction corresponded well with gradients based on phenological field observations from the same region. We conclude that already small and scattered birch image elements allow reliable extraction of key phenological dates for birch species. Devising cameras for species specific analyses of phenological timing will be useful for

  1. Multi-spectral CCD camera system for ocean water color and seacoast observation

    Science.gov (United States)

    Zhu, Min; Chen, Shiping; Wu, Yanlin; Huang, Qiaolin; Jin, Weiqi

    2001-10-01

    One of the earth observing instruments on HY-1 Satellite which will be launched in 2001, the multi-spectral CCD camera system, is developed by Beijing Institute of Space Mechanics & Electricity (BISME), Chinese Academy of Space Technology (CAST). In 798 km orbit, the system can provide images with 250 m ground resolution and a swath of 500 km. It is mainly used for coast zone dynamic mapping and oceanic watercolor monitoring, which include the pollution of offshore and coast zone, plant cover, watercolor, ice, terrain underwater, suspended sediment, mudflat, soil and vapor gross. The multi- spectral camera system is composed of four monocolor CCD cameras, which are line array-based, 'push-broom' scanning cameras, and responding for four spectral bands. The camera system adapts view field registration; that is, each camera scans the same region at the same moment. Each of them contains optics, focal plane assembly, electrical circuit, installation structure, calibration system, thermal control and so on. The primary features on the camera system are: (1) Offset of the central wavelength is better than 5 nm; (2) Degree of polarization is less than 0.5%; (3) Signal-to-noise ratio is about 1000; (4) Dynamic range is better than 2000:1; (5) Registration precision is better than 0.3 pixel; (6) Quantization value is 12 bit.

  2. Cassava brown streak disease in Rwanda, the associated viruses and disease phenotypes.

    Science.gov (United States)

    Munganyinka, E; Ateka, E M; Kihurani, A W; Kanyange, M C; Tairo, F; Sseruwagi, P; Ndunguru, J

    2018-02-01

    Cassava brown streak disease (CBSD) was first observed on cassava ( Manihot esculenta ) in Rwanda in 2009. In 2014 eight major cassava-growing districts in the country were surveyed to determine the distribution and variability of symptom phenotypes associated with CBSD, and the genetic diversity of cassava brown streak viruses. Distribution of the CBSD symptom phenotypes and their combinations varied greatly between districts, cultivars and their associated viruses. The symptoms on leaf alone recorded the highest (32.2%) incidence, followed by roots (25.7%), leaf + stem (20.3%), leaf + root (10.4%), leaf + stem + root (5.2%), stem + root (3.7%), and stem (2.5%) symptoms. Analysis by RT-PCR showed that single infections of Ugandan cassava brown streak virus (UCBSV) were most common (74.2% of total infections) and associated with all the seven phenotypes studied. Single infections of Cassava brown streak virus (CBSV) were predominant (15.3% of total infections) in CBSD-affected plants showing symptoms on stems alone. Mixed infections (CBSV + UCBSV) comprised 10.5% of total infections and predominated in the combinations of leaf + stem + root phenotypes. Phylogenetic analysis and the estimates of evolutionary divergence, using partial sequences (210 nt) of the coat protein gene, revealed that in Rwanda there is one type of CBSV and an indication of diverse UCBSV. This study is the first to report the occurrence and distribution of both CBSV and UCBSV based on molecular techniques in Rwanda.

  3. Effects of Hot Streak Shape on Rotor Heating in a High-Subsonic Single-Stage Turbine

    Science.gov (United States)

    Dorney, Daniel J.; Gundy-Burlet, Karen L.; Norvig, Peter (Technical Monitor)

    1999-01-01

    Experimental data have shown that combustor temperature non-uniformities can lead to the excessive heating of first-stage rotor blades in turbines. This heating of the rotor blades can lead to thermal fatigue and degrade turbine performance. The results of recent studies have shown that variations in the circumferential location (clocking) of the hot streak relative to the first-stage vane airfoils can be used to minimize the adverse effects of the hot streak. The effects of the hot streak/airfoil count ratio on the heating patterns of turbine airfoils have also been evaluated. In the present investigation, three-dimensional unsteady Navier-Stokes simulations have been performed for a single-stage high-pressure turbine operating in high subsonic flow. In addition to a simulation of the baseline turbine, simulations have been performed for circular and elliptical hot streaks of varying sizes in an effort to represent different combustor designs. The predicted results for the baseline simulation show good agreement with the available experimental data. The results of the hot streak simulations indicate: that a) elliptical hot streaks mix more rapidly than circular hot streaks, b) for small hot streak surface area the average rotor temperature is not a strong function of hot streak temperature ratio or shape, and c) hot streaks with larger surface area interact with the secondary flows at the rotor hub endwall, generating an additional high temperature region.

  4. Development of miniaturized proximity focused streak tubes for visible light and x-ray applications. Final report and progress, April-September 1977

    International Nuclear Information System (INIS)

    Cuny, J.J.; Knight, A.J.

    1978-02-01

    Research performed to develop miniaturized proximity focused streak camera tubes (PFST) for application in the visible and the x-ray modes of operation is described. The objective of this research was to provide an engineering design and to fabricate a visible and an x-ray prototype tube to be provided to LASL for test and evaluation. Materials selection and fabrication procedures, particularly the joining of beryllium to a suitable support ring for use as the x-ray window, are described in detail. The visible and x-ray PFST's were successfully fabricated

  5. Pedicle streaking: A novel and simple aid in pedicle positioning in free tissue transfer

    Directory of Open Access Journals (Sweden)

    Aditya Aggarwal

    2015-01-01

    Full Text Available Introduction: The pedicle positioning in free tissue transfer is critical to its success. Long thin pedicles are especially prone to this complication where even a slight twist in the perforator can result in flap loss. Pedicles passing through the long tunnels are similarly at risk. Streaking the pedicle with methylene blue is a simple and safe method which increases the safety of free tissue transfer. Materials and Methods: Once the flap is islanded on the pedicle and the vascularity of the flap is confirmed, the pedicle is streaked with methylene blue dye at a distance of 6-7 mm. The streaking starts from the origin of the vessels and continued distally on to the under surface of flap to mark the complete course of the pedicle in alignment. The presence of streaking in some parts and not in rest indicates twist in the pedicle. Observation and Results: Four hundred and sixty five free flaps have been done at our centre in the last 5 years. The overall success rate of free flaps is 95.3% (22 free flap failures. There has not been a single case of pedicle twist leading to flap congestion and failure. Conclusion: This simple and novel method is very reliable for pedicle positioning avoiding any twist necessary for successful free tissue transfer.

  6. Observing bodies. Camera surveillance and the significance of the body.

    NARCIS (Netherlands)

    Dubbeld, L.

    2003-01-01

    At the most mundane level, CCTV observes bodies, and as such attaches great importance to the specific features of the human body. At the same time, however, bodies tend to disappear, as they are represented electronically by the camera monitors and, in the case of image recording, by the computer

  7. ANTIOXIDANT EFFECTS OF L-SERINE AGAINST FATTY STREAK FORMATION IN HYPERCHOLESTEROLEMIC ANIMALS

    Directory of Open Access Journals (Sweden)

    Ahmad Movahedian

    2010-12-01

    Full Text Available   Abstract INTRODUCTION: Peroxidation of blood lipoproteins is regarded as a key event in the development of atherosclerosis. Evidence suggests that oxidative modification of amino acids in low-density lipoprotein (LDL particles leads to its convert into an atherogenic form, which is taken up by macrophages. Therefore the reduction of oxidative modification of lipoproteins by increasing plasma antioxidant capacity may prevent cardiovascular disease. methods: In this study, the antioxidant and anti-fatty streak effects of L-serine were investigated in hypercholesterolemic rabbits. Rabbits were randomly divided into three groups which were fed high-cholesterol diet (hypercholesterolemic control group, high-cholesterol + L-serine diet (treatment group, and normal diet (control for twelve weeks and then blood samples were obtained to measure plasma cholesterol, triglyceride (TG, high-density lipoprotein (HDL, low-density lipoprotein (LDL, antioxidant capacity (AC, malondialdehyde (MDA, and conjugated dienes (CDS. Right and left coronary arteries were also obtained for histological evaluation. results: No significant difference was observed in plasma cholesterol, TG, HDL, LDL and CDS levels between treatment and hypercholesterolemic control groups (P>0.05. The levels of plasma MDA and AC were 0.29‌ µM and 56%, respectively in the treatment group which showed a significant change in comparison with hypercholesterolemic control groups (P<0.05. The mean size of produced fatty streak also showed significant reduction in the treatment group compared to the hypercholesterolemic group (P<0.05. CONCLUSIONS: The results showed that L-serine has antioxidant and anti-fatty streak effects without any influence on plasma lipid levels in hypercholesterolemic rabbits.     Keywords: Atherosclerosis, cholesterol, L-serine, antioxidant, lipids, fatty streak.

  8. Electron streaking in the autoionization region of H2

    International Nuclear Information System (INIS)

    Palacios, Alicia; González-Castrillo, Alberto; Martín, Fernando

    2015-01-01

    We use a UV-pump/IR-probe scheme, combining a single attosecond UV pulse and a 750 nm IR pulse, to explore laser-assisted photoionization of the hydrogen molecule in the autoionization region. The electron energy distributions exhibit unusual streaking patterns that are explored for different angles of the electron ejection with respect to the polarization vector and the molecular axis. Moreover, by controlling the time delay between the pulses, we observe that one can suppress the autoionization channel. (paper)

  9. 100-ps framing-camera tube

    International Nuclear Information System (INIS)

    Kalibjian, R.

    1978-01-01

    The optoelectronic framing-camera tube described is capable of recording two-dimensional image frames with high spatial resolution in the <100-ps range. Framing is performed by streaking a two-dimensional electron image across narrow slits. The resulting dissected electron line images from the slits are restored into framed images by a restorer deflector operating synchronously with the dissector deflector. The number of framed images on the tube's viewing screen equals the number of dissecting slits in the tube. Performance has been demonstrated in a prototype tube by recording 135-ps-duration framed images of 2.5-mm patterns at the cathode. The limitation in the framing speed is in the external drivers for the deflectors and not in the tube design characteristics. Faster frame speeds in the <100-ps range can be obtained by use of faster deflection drivers

  10. Streaked x-ray spectrometer having a discrete selection of Bragg geometries for Omega

    Energy Technology Data Exchange (ETDEWEB)

    Millecchia, M.; Regan, S. P.; Bahr, R. E.; Romanofsky, M.; Sorce, C. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623-1299 (United States)

    2012-10-15

    The streaked x-ray spectrometer (SXS) is used with streak cameras [D. H. Kalantar, P. M. Bell, R. L. Costa, B. A. Hammel, O. L. Landen, T. J. Orzechowski, J. D. Hares, and A. K. L. Dymoke-Bradshaw, in 22nd International Congress on High-Speed Photography and Photonics, edited by D. L. Paisley and A. M. Frank (SPIE, Bellingham, WA, 1997), Vol. 2869, p. 680] positioned with a ten-inch manipulator on OMEGA [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)] and OMEGA EP [L. J. Waxer et al., Presented at CLEO/QELS 2008, San Jose, CA, 4-9 May 2008 (Paper JThB1)] for time-resolved, x-ray spectroscopy of laser-produced plasmas in the 1.4- to 20-keV photon-energy range. These experiments require measuring a portion of this photon-energy range to monitor a particular emission or absorption feature of interest. The SXS relies on a pinned mechanical reference system to create a discrete set of Bragg reflection geometries for a variety of crystals. A wide selection of spectral windows is achieved accurately and efficiently using this technique. It replaces the previous spectrometer designs that had a continuous Bragg angle adjustment and required a tedious alignment calibration procedure. The number of spectral windows needed for the SXS was determined by studying the spectral ranges selected by OMEGA users over the last decade. These selections are easily configured in the SXS using one of the 25 discrete Bragg reflection geometries and one of the six types of Bragg crystals, including two curved crystals.

  11. X-ray imaging of JET. A design study for a streak camera application

    International Nuclear Information System (INIS)

    Bateman, J.E.; Hobby, M.G.

    1980-03-01

    A single dimensional imaging system is proposed which will image a strip of the JET plasma up to 320 times per shot with a time resolution of better than 50 μs using the bremsstrahlung X-rays. The images are obtained by means of a pinhole camera followed by an X-ray image intensifier system the output of which is in turn digitised by a photodiode array. The information is stored digitally in a fast memory and is immediately available for display or analysis. (author)

  12. Spatiotemporal mechanical variation reveals critical role for rho kinase during primitive streak morphogenesis.

    Science.gov (United States)

    Henkels, Julia; Oh, Jaeho; Xu, Wenwei; Owen, Drew; Sulchek, Todd; Zamir, Evan

    2013-02-01

    Large-scale morphogenetic movements during early embryo development are driven by complex changes in biochemical and biophysical factors. Current models for amniote primitive streak morphogenesis and gastrulation take into account numerous genetic pathways but largely ignore the role of mechanical forces. Here, we used atomic force microscopy (AFM) to obtain for the first time precise biomechanical properties of the early avian embryo. Our data reveal that the primitive streak is significantly stiffer than neighboring regions of the epiblast, and that it is stiffer than the pre-primitive streak epiblast. To test our hypothesis that these changes in mechanical properties are due to a localized increase of actomyosin contractility, we inhibited actomyosin contractility via the Rho kinase (ROCK) pathway using the small-molecule inhibitor Y-27632. Our results using several different assays show the following: (1) primitive streak formation was blocked; (2) the time-dependent increase in primitive streak stiffness was abolished; and (3) convergence of epiblast cells to the midline was inhibited. Taken together, our data suggest that actomyosin contractility is necessary for primitive streak morphogenesis, and specifically, ROCK plays a critical role. To better understand the underlying mechanisms of this fundamental process, future models should account for the findings presented in this study.

  13. On-Orbit Camera Misalignment Estimation Framework and Its Application to Earth Observation Satellite

    Directory of Open Access Journals (Sweden)

    Seungwoo Lee

    2015-03-01

    Full Text Available Despite the efforts for precise alignment of imaging sensors and attitude sensors before launch, the accuracy of pre-launch alignment is limited. The misalignment between attitude frame and camera frame is especially important as it is related to the localization error of the spacecraft, which is one of the essential factors of satellite image quality. In this paper, a framework for camera misalignment estimation is presented with its application to a high-resolution earth-observation satellite—Deimos-2. The framework intends to provide a solution for estimation and correction of the camera misalignment of a spacecraft, covering image acquisition planning to mathematical solution of camera misalignment. Considerations for effective image acquisition planning to obtain reliable results are discussed, followed by a detailed description on a practical method for extracting many GCPs automatically using reference ortho-photos. Patterns of localization errors that commonly occur due to the camera misalignment are also investigated. A mathematical model for camera misalignment estimation is described comprehensively. The results of simulation experiments showing the validity and accuracy of the misalignment estimation model are provided. The proposed framework was applied to Deimos-2. The real-world data and results from Deimos-2 are presented.

  14. Electro-optical design of a long slit streak tube

    Science.gov (United States)

    Tian, Liping; Tian, Jinshou; Wen, Wenlong; Chen, Ping; Wang, Xing; Hui, Dandan; Wang, Junfeng

    2017-11-01

    A small size and long slit streak tube with high spatial resolution was designed and optimized. Curved photocathode and screen were adopted to increase the photocathode working area and spatial resolution. High physical temporal resolution obtained by using a slit accelerating electrode. Deflection sensitivity of the streak tube was improved by adopting two-folded deflection plates. The simulations indicate that the photocathode effective working area can reach 30mm × 5mm. The static spatial resolution is higher than 40lp/mm and 12lp/mm along scanning and slit directions respectively while the physical temporal resolution is higher than 60ps. The magnification is 0.75 and 0.77 in scanning and slit directions. And also, the deflection sensitivity is as high as 37mm/kV. The external dimension of the streak tube are only ∅74mm×231mm. Thus, it can be applied to laser imaging radar system for large field of view and high range precision detection.

  15. Pea Streak Virus Recorded in Europe

    Czech Academy of Sciences Publication Activity Database

    Sarkisova, Tatiana; Bečková, M.; Fránová, Jana; Petrzik, Karel

    2016-01-01

    Roč. 52, č. 3 (2016), s. 164-166 ISSN 1212-2580 R&D Projects: GA MZe QH71145 Institutional support: RVO:60077344 Keywords : Pea streak virus * alfalfa * carlavirus * partial sequence Subject RIV: EE - Microbiology, Virology Impact factor: 0.742, year: 2016

  16. Detection, Occurrence, and Survey of Rice Stripe and Black-Streaked Dwarf Diseases in Zhejiang Province, China

    OpenAIRE

    Heng-mu ZHANG; Hua-di WANG; Jian YANG; Michael J ADAMS; Jian-ping CHEN

    2013-01-01

    The major viral diseases that occur on rice plants in Zhejiang Province, eastern China, are stripe and rice black-streaked dwarf diseases. Rice stripe disease is only caused by rice stripe tenuivirus (RSV), while rice black-streaked dwarf disease can be caused by rice black-streaked dwarf fijivirus (RBSDV) and/or southern rice black-streaked dwarf fijivirus (SRBSDV). Here we review the characterization of these viruses, methods for their detection, and extensive surveys showing their occurren...

  17. Novel technique for addressing streak artifact in gated dual-source MDCT angiography utilizing ECG-editing

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Laura T.; Boll, Daniel T. [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC (United States)

    2008-11-15

    Streak artifact is an important source of image degradation in computed tomographic imaging. In coronary MDCT angiography, streak artifact from pacemaker leads in the SVC can render segments of the right coronary artery uninterpretable. With current technology in clinical practice, there is no effective way to eliminate streak artifact in coronary MDCT angiography entirely. We propose a technique to minimize the impact of streak artifact in retrospectively gated coronary MDCT angiography by utilizing small shifts in the reconstruction window. In our experience, previously degraded portions of the coronary vasculature were able to be well evaluated using this technique. (orig.)

  18. The effect of wall temperature distribution on streaks in compressible turbulent boundary layer

    Science.gov (United States)

    Zhang, Zhao; Tao, Yang; Xiong, Neng; Qian, Fengxue

    2018-05-01

    The thermal boundary condition at wall is very important for the compressible flow due to the coupling of the energy equation, and a lot of research works about it were carried out in past decades. In most of these works, the wall was assumed as adiabatic or uniform isothermal surface; the flow over a thermal wall with some special temperature distribution was seldom studied. Lagha studied the effect of uniform isothermal wall on the streaks, and pointed out that higher the wall temperature is, the longer the streak (POF, 2011, 23, 015106). So, we designed streamwise stripes of wall temperature distribution on the compressible turbulent boundary layer at Mach 3.0 to learn the effect on the streaks by means of direct numerical simulation in this paper. The mean wall temperature is equal to the adiabatic case approximately, and the width of the temperature stripes is in the same order as the width of the streaks. The streak patterns in near-wall region with different temperature stripes are shown in the paper. Moreover, we find that there is a reduction of friction velocity with the wall temperature stripes when compared with the adiabatic case.

  19. Nondipole effects in attosecond photoelectron streaking

    DEFF Research Database (Denmark)

    Spiewanowski, Maciek; Madsen, Lars Bojer

    2012-01-01

    The influence of nondipole terms on the time delay in photoionization by an extreme-ultraviolet attosecond pulse in the presence of a near-infrared femtosecond laser pulse from 1s, 2s, and 2p states in hydrogen is investigated. In this attosecond photoelectron streaking process, the relative...

  20. Development of the Earth Observation Camera of MIRIS

    Directory of Open Access Journals (Sweden)

    Dae-Hee Lee

    2011-09-01

    Full Text Available We have designed and manufactured the Earth observation camera (EOC of multi-purpose infrared imaging system (MIRIS. MIRIS is a main payload of the STSAT-3, which will be launched in late 2012. The main objective of the EOC is to test the operation of Korean IR technology in space, so we have designed the optical and mechanical system of the EOC to fit the IR detector system. We have assembled the flight model (FM of EOC and performed environment tests successfully. The EOC is now ready to be integrated into the satellite system waiting for operation in space, as planned.

  1. Mechanism for propagation of the step leader of streak lightning

    International Nuclear Information System (INIS)

    Golubev, A.I.; Zolotovskil, V.I.; Ivanovskil, A.V.

    1992-01-01

    A hypothetical scheme for the development of the step leader of streak lightning is discussed. The mathematical problem of modeling the propagation of the leader in this scheme is stated. The main parameters of the leader are estimated: the length and propagation velocity of the step, the average propagation velocity, etc. This is compared with data from observations in nature. The propagation of the leader is simulated numerically. Results of the calculation are presented for two 'flashes' of the step leader. 25 refs., 6 figs

  2. An evaluation of the effectiveness of observation camera placement within the MeerKAT radio telescope project

    Directory of Open Access Journals (Sweden)

    Heyns, Andries

    2015-08-01

    Full Text Available A recent development within the MeerKAT sub-project of the Square Kilometre Array radio telescope network was the placement of a network of three observation cameras in pursuit of two specific visibility objectives. In this paper, we evaluate the effectiveness of the locations of the MeerKAT observation camera network according to a novel multi-objective geographic information systems-based facility location framework. We find that the configuration chosen and implemented by the MeerKAT decision-makers is of very high quality, although we are able to uncover slightly superior alternative placement configurations. A significant amount of time and effort could, however, have been saved in the process of choosing the appropriate camera sites, had our solutions been available to the decision-makers.

  3. Streak artifacts on Kidney CT: Ionic vs nonionic contrast media

    International Nuclear Information System (INIS)

    Cho, Eun Ok; Kim, Won Hong; Jung, Myung Suk; Kim, Yong Hoon; Hur, Gham

    1993-01-01

    The authors reviewed findings of enhanced abdominal computed tomography (CT) scans to know the difference between a higher dose of conventional ionic contrast media(iothalamate meglumine) and a lower dose of a new, nonionic contrast material(ioversol). One hundred adult patients were divided into two groups. Each group consisted of 50 patients. Iothalamate meglumine and ioversol were intravenously administered in each group. The radio of the male to female in the former was 28:22, and the latter 29:21. We examine the degree of renal streak artifact and measure the Hounsfield number of urine in renal collecting system. There were significant differences of the degree of the streak artifact depending upon the osmolality of contrast media used and that was related with urine CT number(P value<0.005). We authors conclude that nonionic low osmolar contrast media is prone to cause streak artifacts and distortions of renal image than conventional ionic high osmolar contrast media

  4. POD analysis of the instability mode of a low-speed streak in a laminar boundary layer

    Science.gov (United States)

    Deng, Si-Chao; Pan, Chong; Wang, Jin-Jun; Rinoshika, Akira

    2017-12-01

    The instability of one single low-speed streak in a zero-pressure-gradient laminar boundary layer is investigated experimentally via both hydrogen bubble visualization and planar particle image velocimetry (PIV) measurement. A single low-speed streak is generated and destabilized by the wake of an interference wire positioned normal to the wall and in the upstream. The downstream development of the streak includes secondary instability and self-reproduction process, which leads to the generation of two additional streaks appearing on either side of the primary one. A proper orthogonal decomposition (POD) analysis of PIV measured velocity field is used to identify the components of the streak instability in the POD mode space: for a sinuous/varicose type of POD mode, its basis functions present anti-symmetric/symmetric distributions about the streak centerline in the streamwise component, and the symmetry condition reverses in the spanwise component. It is further shown that sinuous mode dominates the turbulent kinematic energy (TKE) through the whole streak evolution process, the TKE content first increases along the streamwise direction to a saturation value and then decays slowly. In contrast, varicose mode exhibits a sustained growth of the TKE content, suggesting an increasing competition of varicose instability against sinuous instability.

  5. Streaked spectrometry using multilayer x-ray-interference mirrors to investigate energy transport in laser-plasma applications

    International Nuclear Information System (INIS)

    Stradling, G.L.; Barbee, T.W. Jr.; Henke, B.L.; Campbell, E.M.; Mead, W.C.

    1981-08-01

    Transport of energy in laser-produced plasmas is scrutinized by devising spectrally and temporally identifiable characteristics in the x-ray emission history which identify the heat-front position at various times in the heating process. Measurements of the relative turn-on times of these characteristics show the rate of energy transport between various points. These measurements can in turn constrain models of energy transport phenomena. We are time-resolving spectrally distinguishable subkilovolt x-ray emissions from different layers of a disk target to examine the transport rate of energy into the target. A similar technique is used to measure the lateral expansion rate of the plasma spot. A soft x-ray streak camera with 15-psec temporal resolution is used to make the temporal measurements. Spectral discrimination of the incident signal is provided by multilayer x-ray interference mirrors

  6. Multi‐angular observations of vegetation indices from UAV cameras

    DEFF Research Database (Denmark)

    Sobejano-Paz, Veronica; Wang, Sheng; Jakobsen, Jakob

    Unmanned aerial vehicles (UAVs) are found as an alternative to the classical manned aerial photogrammetry, which can be used to obtain environmental data or as a complementary solution to other methods (Nex and Remondino, 2014). Although UAVs have coverage limitations, they have better resolution...... (Berni et al., 2009), hyper spectral camera (Burkart et al., 2015) and photometric elevation mapping sensor (Shahbazi et al., 2015) among others. Therefore, UAVs can be used in many fields such as agriculture, forestry, archeology, architecture, environment and traffic monitoring (Nex and Remondino, 2014......). In this study, the UAV used is a hexacopter s900 equipped with a Global Positioning System (GPS) and two cameras; a digital RGB photo camera and a multispectral camera (MCA), with a resolution of 5472 x 3648 pixels and 1280 x 1024 pixels, respectively. In terms of applications, traditional methods using...

  7. First measurements of electron-beam transit times and micropulse elongation in a photoelectric injector at the High-Brightness Accelerator FEL (HIBAF)

    Energy Technology Data Exchange (ETDEWEB)

    Lumpkin, A.H.; Carlsten, B.E.; Feldman, R.B.

    1990-01-01

    Key aspects of the dynamics of a photoelectric injector (PEI) on the Los Alamos High-Brightness Accelerator FEL (HIBAF) facility have been investigated using a synchroscan streak camera. By phase-locking the streak camera sweep to the reference 108.3 MHz rf signal, the variations of micropulse temporal elongations (30 to 80% over the drive-laser pulse length) and of transit times (25 ps for a 16{degree}-phase change) were observed for the first time. These results were in good agreement with PARMELA simulations. 2 refs., 8 figs.

  8. Framing-camera tube developed for sub-100-ps range

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    A new framing-camera tube, developed by Electronics Engineering, is capable of recording two-dimensional image frames with high spatial resolution in the sub-100-ps range. Framing is performed by streaking a two-dimensional electron image across narrow slits; the resulting electron-line images from the slits are restored into a framed image by a restorer deflector operating synchronously with the dissector deflector. We have demonstrated its performance in a prototype tube by recording 125-ps-duration framed images of 2.5-mm patterns. The limitation in the framing speed is in the external electronic drivers for the deflectors and not in the tube design characteristics. Shorter frame durations (below 100 ps) can be obtained by use of faster deflection drivers

  9. X-ray streak crystal spectography

    International Nuclear Information System (INIS)

    Kauffman, R.L.; Brown, T.; Medecki, H.

    1983-01-01

    We have built an x-ray streaked crystal spectrograph for making time-resolved x-ray spectral measurements. This instrument can access Bragg angles from 11 0 to 38 0 and x-ray spectra from 200 eV to greater than 10 keV. We have demonstrated resolving powers, E/δE > 200 at 1 keV and time resolution less than 20 psec. A description of the instrument and an example of the data is given

  10. Proceedings of the 18th international congress on high speed photography and photonics

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    The subjects addressed at the conference presented in this book include image converter and intensifier cameras; opto-mechanical high speed cameras; X-ray generator and radiography; and Holography and interferometry. The papers include Flash x-ray cineradiography; New picosecond synchroscan streak image tube; and Streak camera CCD readout system

  11. New continuous recording procedure of holographic information on transient phenomena

    Science.gov (United States)

    Nagayama, Kunihito; Nishihara, H. Keith; Murakami, Terutoshi

    1992-09-01

    A new method for continuous recording of holographic information, 'streak holography,' is proposed. This kind of record can be useful for velocity and acceleration measurement as well as for observing a moving object whose trajectory cannot be predicted in advance. A very high speed camera system has been designed and constructed for streak holography. A ring-shaped 100-mm-diam film has been cut out from the high-resolution sheet film and mounted on a thin duralmin disk, which has been driven to rotate directly by an air-turbine spindle. Attainable streak velocity is 0.3 mm/microsecond(s) . A direct film drive mechanism makes it possible to use a relay lens system of extremely small f number. The feasibility of the camera system has been demonstrated by observing several transient events, such as the forced oscillation of a wire and the free fall of small glass particles, using an argon-ion laser as a light source.

  12. Analyses of Twelve New Whole Genome Sequences of Cassava Brown Streak Viruses and Ugandan Cassava Brown Streak Viruses from East Africa: Diversity, Supercomputing and Evidence for Further Speciation

    Science.gov (United States)

    Ndunguru, Joseph; Sseruwagi, Peter; Tairo, Fred; Stomeo, Francesca; Maina, Solomon; Djinkeng, Appolinaire; Kehoe, Monica; Boykin, Laura M.

    2015-01-01

    Cassava brown streak disease is caused by two devastating viruses, Cassava brown streak virus (CBSV) and Ugandan cassava brown streak virus (UCBSV) which are frequently found infecting cassava, one of sub-Saharan Africa’s most important staple food crops. Each year these viruses cause losses of up to $100 million USD and can leave entire families without their primary food source, for an entire year. Twelve new whole genomes, including seven of CBSV and five of UCBSV were uncovered in this research, doubling the genomic sequences available in the public domain for these viruses. These new sequences disprove the assumption that the viruses are limited by agro-ecological zones, show that current diagnostic primers are insufficient to provide confident diagnosis of these viruses and give rise to the possibility that there may be as many as four distinct species of virus. Utilizing NGS sequencing technologies and proper phylogenetic practices will rapidly increase the solution to sustainable cassava production. PMID:26439260

  13. Analyses of Twelve New Whole Genome Sequences of Cassava Brown Streak Viruses and Ugandan Cassava Brown Streak Viruses from East Africa: Diversity, Supercomputing and Evidence for Further Speciation.

    Directory of Open Access Journals (Sweden)

    Joseph Ndunguru

    Full Text Available Cassava brown streak disease is caused by two devastating viruses, Cassava brown streak virus (CBSV and Ugandan cassava brown streak virus (UCBSV which are frequently found infecting cassava, one of sub-Saharan Africa's most important staple food crops. Each year these viruses cause losses of up to $100 million USD and can leave entire families without their primary food source, for an entire year. Twelve new whole genomes, including seven of CBSV and five of UCBSV were uncovered in this research, doubling the genomic sequences available in the public domain for these viruses. These new sequences disprove the assumption that the viruses are limited by agro-ecological zones, show that current diagnostic primers are insufficient to provide confident diagnosis of these viruses and give rise to the possibility that there may be as many as four distinct species of virus. Utilizing NGS sequencing technologies and proper phylogenetic practices will rapidly increase the solution to sustainable cassava production.

  14. Avoiding acidic region streaking in two-dimensional gel ...

    Indian Academy of Sciences (India)

    Supplementary figure 6. 2DE gel images ... Number of acidic streaks. Fedyunin et al. 2012. 4.02. 6. Zuo et al. 2000. 2.54. 9. Valenete et ... CE, 3rd 2009 Proteasomal protein degradation in ... Nandakumar MP, Shen J, Raman B and Marten MR.

  15. Atomic and molecular phases through attosecond streaking

    DEFF Research Database (Denmark)

    Baggesen, Jan Conrad; Madsen, Lars Bojer

    2011-01-01

    phase of the atomic or molecular ionization matrix elements from the two states through the interference from the two channels. The interference may change the phase of the photoelectron streaking signal within the envelope of the infrared field, an effect to be accounted for when reconstructing short...... pulses from the photoelectron signal and in attosecond time-resolved measurements....

  16. Observations of temporal change of nighttime cloud cover from Himawari 8 and ground-based sky camera over Chiba, Japan

    Science.gov (United States)

    Lagrosas, N.; Gacal, G. F. B.; Kuze, H.

    2017-12-01

    Detection of nighttime cloud from Himawari 8 is implemented using the difference of digital numbers from bands 13 (10.4µm) and 7 (3.9µm). The digital number difference of -1.39x104 can be used as a threshold to separate clouds from clear sky conditions. To look at observations from the ground over Chiba, a digital camera (Canon Powershot A2300) is used to take images of the sky every 5 minutes at an exposure time of 5s at the Center for Environmental Remote Sensing, Chiba University. From these images, cloud cover values are obtained using threshold algorithm (Gacal, et al, 2016). Ten minute nighttime cloud cover values from these two datasets are compared and analyzed from 29 May to 05 June 2017 (20:00-03:00 JST). When compared with lidar data, the camera can detect thick high level clouds up to 10km. The results show that during clear sky conditions (02-03 June), both camera and satellite cloud cover values show 0% cloud cover. During cloudy conditions (05-06 June), the camera shows almost 100% cloud cover while satellite cloud cover values range from 60 to 100%. These low values can be attributed to the presence of low-level thin clouds ( 2km above the ground) as observed from National Institute for Environmental Studies lidar located inside Chiba University. This difference of cloud cover values shows that the camera can produce accurate cloud cover values of low level clouds that are sometimes not detected by satellites. The opposite occurs when high level clouds are present (01-02 June). Derived satellite cloud cover shows almost 100% during the whole night while ground-based camera shows cloud cover values that range from 10 to 100% during the same time interval. The fluctuating values can be attributed to the presence of thin clouds located at around 6km from the ground and the presence of low level clouds ( 1km). Since the camera relies on the reflected city lights, it is possible that the high level thin clouds are not observed by the camera but is

  17. Numerical Investigation on the Influence of Hot Streak Temperature Ratio in a High-Pressure Stage of Vaneless Counter-Rotating Turbine

    Directory of Open Access Journals (Sweden)

    Zhao Qingjun

    2007-01-01

    Full Text Available The results of recent studies have shown that combustor exit temperature distortion can cause excessive heat load of high-pressure turbine (HPT rotor blades. The heating of HPT rotor blades can lead to thermal fatigue and degrade turbine performance. In order to explore the influence of hot streak temperature ratio on the temperature distributions of HPT airfoil surface, three-dimensional multiblade row unsteady Navier-Stokes simulations have been performed in a vaneless counter-rotating turbine (VCRT. The hot streak temperature ratios from 1.0 (without hot streak to 2.4 were used in these numerical simulations, including 1.0, 1.2, 1.6, 2.0, and 2.4 temperature ratios. The hot streak is circular in shape with a diameter equal to 25% of the span. The center of the hot streak is located at 50% of span and 0% of pitch (the leading edge of the HPT stator vane. The predicted results show that the hot streak is relatively unaffected as it migrates through the HPT stator. The hot streak mixes with the vane wake and convects towards the pressure surface (PS of the HPT rotor when it moves over the vane surface of the HPT stator. The heat load of the HPT rotor increases with the increase of the hot streak temperature ratio. The existence of the inlet temperature distortion induces a thin layer of cooler air in the HPT rotor, which separates the PS of the HPT rotor from the hotter fluid. The numerical results also indicating the migration characteristics of the hot streak in the HPT rotor are predominated by the combined effects of secondary flow and buoyancy. The combined effects that induce the high-temperature fluid migrate towards the hub on the HPT rotor. The effect of the secondary flow on the hotter fluid increases as the hot streak temperature ratio is increased. The influence of buoyancy is directly proportional to the hot streak temperature ratio. The predicted results show that the increase of the hot streak temperature ratio trends to increase

  18. Neutron imaging system based on a video camera

    International Nuclear Information System (INIS)

    Dinca, M.

    2004-01-01

    possess versatile and unique readout capabilities that have established their utility in scientific and especially for radiation field applications. A detector for neutron radiography based on a cooled CID camera offers some capabilities, as follows: - Extended linear dynamic range up to 109 without blooming or streaking; - Arbitrary pixel selection and nondestructive readout makes it possible to introduce a high degree of exposure control to low-light viewing of static scenes; - Read multiple areas of interest of an image within a given frame at higher rates; - Wide spectral response (185 nm - 1100 nm); - CIDs tolerate high radiation environments up to 3 Mrad integrated dose; - The contiguous pixel structure of CID arrays contributes to accurate imaging because there are virtually no opaque areas between pixels. (author)

  19. Intensified CCD for ultrafast diagnostics

    International Nuclear Information System (INIS)

    Cheng, J.; Tripp, G.; Coleman, L.

    1978-01-01

    Many of the present laser fusion diagnostics are recorded on either ultrafast streak cameras or on oscilloscopes. For those experiments in which a large volume of data is accumulated, direct computer processing of the information becomes important. We describe an approach which uses a RCA 52501 back-thinned CCD sensor to obtain direct electron readouts for both the streak camera and the CRT. Performance of the 100 GHz streak camera and the 4 GHz CRT are presented. Design parameters and computer interfacing for both systems are described in detail

  20. Time-resolved soft-x-ray studies of energy transport in layered and planar laser-driven targets

    International Nuclear Information System (INIS)

    Stradling, G.L.

    1982-01-01

    New low-energy x-ray diagnostic techniques are used to explore energy-transport processes in laser heated plasmas. Streak cameras are used to provide 15-psec time-resolution measurements of subkeV x-ray emission. A very thin (50 μg/cm 2 ) carbon substrate provides a low-energy x-ray transparent window to the transmission photocathode of this soft x-ray streak camera. Active differential vacuum pumping of the instrument is required. The use of high-sensitivity, low secondary-electron energy-spread CsI photocathodes in x-ray streak cameras is also described. Significant increases in sensitivity with only a small and intermittant decrease in dynamic range were observed. These coherent, complementary advances in subkeV, time-resolved x-ray diagnostic capability are applied to energy-transport investigations of 1.06-μm laser plasmas. Both solid disk targets of a variety of Z's as well as Be-on-Al layered-disk targets were irradiated with 700-psec laser pulses of selected intensity between 3 x 10 14 W/cm 2 and 1 x 10 15 W/cm 2

  1. A Demographic Model to Evaluate Population Declines in the Endangered Streaked Horned Lark

    Directory of Open Access Journals (Sweden)

    Alaine F. Camfield

    2011-12-01

    Full Text Available The Streaked Horned Lark (Eremophila alpestris strigata is listed as endangered by the State of Washington, USA and by Canada under the Species at Risk Act and is also classified as a federal candidate for listing under the Endangered Species Act in the USA. A substantial portion of Streaked Horned Lark habitat has been lost or degraded, and range contraction has occurred in Oregon, Washington, and British Columbia. We estimate the vital rates (fecundity, adult and juvenile survival and population growth rate (λ for Streaked Horned Larks breeding in Washington, USA and conduct a Life-Stage Simulation Analysis (LSA to evaluate which vital rate has the greatest influence on λ. We simulated changes in the three vital rates to examine how much they would need to be adjusted either independently or in concert to achieve a stable Streaked Horned Lark population (λ = 1. We also evaluated which fecundity component (the number of fledglings per egg laid or renesting interval had the greatest impact on λ. The estimate of population growth suggests that Streaked Horned Larks in Washington are declining rapidly (λ = 0.62 ± 0.10 and that local breeding sites are not sustainable without immigration. The LSA results indicate that adult survival had the greatest influence on λ, followed by juvenile survival and fecundity. However, increases in vital rates led to λ = 1 only when adult survival was raised from 0.47 to 0.85, juvenile survival from 0.17 to 0.58, and fecundity from 0.91 to 3.09. Increases in breeding success and decreases in the renesting interval influenced λ similarly; however, λ did not reach 1 even when breeding success was raised to 100% or renesting intervals were reduced to 1 day. Only when all three vital rates were increased simultaneously did λ approach 1 without requiring highly unrealistic increases in each vital rate. We conclude that conservation activities need to target all or multiple vital rates to be successful. The

  2. Precise optical observation of 0.5-GPa shock waves in condensed materials

    Science.gov (United States)

    Nagayama, Kunihito; Mori, Yasuhito

    1999-06-01

    Precision optical observation method was developed to study impact-generated high-pressure shock waves in condensed materials. The present method makes it possible to sensitively detect the shock waves of the relatively low shock stress around 0.5 GPa. The principle of the present method is based on the use of total internal reflection by triangular prisms placed on the free surface of a target assembly. When a plane shock wave arrives at the free surface, the light reflected from the prisms extinguishes instantaneously. The reason is that the total internal reflection changes to the reflection depending on micron roughness of the free surface after the shock arrival. The shock arrival at the bottom face of the prisms can be detected here by two kinds of methods, i.e., a photographic method and a gauge method. The photographic method is an inclined prism method of using a high-speed streak camera. The shock velocity and the shock tilt angle can be estimated accurately from an obtained streak photograph. While in the gauge method, an in-material PVDF stress gauge is combined with an optical prism-pin. The PVDF gauge records electrically the stress profile behind the shockwave front, and the Hugoniot data can be precisely measured by combining the prism pin with the PVDF gauge.

  3. Relationships between early spring wheat streak mosaic severity levels and grain yield: Implications for management decisions

    Science.gov (United States)

    Wheat streak mosaic (WSM) caused by Wheat streak mosaic virus, which is transmitted by the wheat curl mite (Aceria tosichella), is a major yield-limiting disease in the Texas High Plains. In addition to its impact on grain production, the disease reduces water-use efficiency by affecting root develo...

  4. Molecular characterization of Banana streak virus isolate from Musa Acuminata in China.

    Science.gov (United States)

    Zhuang, Jun; Wang, Jian-Hua; Zhang, Xin; Liu, Zhi-Xin

    2011-12-01

    Banana streak virus (BSV), a member of genus Badnavirus, is a causal agent of banana streak disease throughout the world. The genetic diversity of BSVs from different regions of banana plantations has previously been investigated, but there are relatively few reports of the genetic characteristic of episomal (non-integrated) BSV genomes isolated from China. Here, the complete genome, a total of 7722bp (GenBank accession number DQ092436), of an isolate of Banana streak virus (BSV) on cultivar Cavendish (BSAcYNV) in Yunnan, China was determined. The genome organises in the typical manner of badnaviruses. The intergenic region of genomic DNA contains a large stem-loop, which may contribute to the ribosome shift into the following open reading frames (ORFs). The coding region of BSAcYNV consists of three overlapping ORFs, ORF1 with a non-AUG start codon and ORF2 encoding two small proteins are individually involved in viral movement and ORF3 encodes a polyprotein. Besides the complete genome, a defective genome lacking the whole RNA leader region and a majority of ORF1 and which encompasses 6525bp was also isolated and sequenced from this BSV DNA reservoir in infected banana plants. Sequence analyses showed that BSAcYNV has closest similarity in terms of genome organization and the coding assignments with an BSV isolate from Vietnam (BSAcVNV). The corresponding coding regions shared identities of 88% and -95% at nucleotide and amino acid levels, respectively. Phylogenetic analysis also indicated BSAcYNV shared the closest geographical evolutionary relationship to BSAcVNV among sequenced banana streak badnaviruses.

  5. A maize resistance gene functions against bacterial streak disease in rice.

    Science.gov (United States)

    Zhao, Bingyu; Lin, Xinghua; Poland, Jesse; Trick, Harold; Leach, Jan; Hulbert, Scot

    2005-10-25

    Although cereal crops all belong to the grass family (Poacea), most of their diseases are specific to a particular species. Thus, a given cereal species is typically resistant to diseases of other grasses, and this nonhost resistance is generally stable. To determine the feasibility of transferring nonhost resistance genes (R genes) between distantly related grasses to control specific diseases, we identified a maize R gene that recognizes a rice pathogen, Xanthomonas oryzae pv. oryzicola, which causes bacterial streak disease. Bacterial streak is an important disease of rice in Asia, and no simply inherited sources of resistance have been identified in rice. Although X. o. pv. oryzicola does not cause disease on maize, we identified a maize gene, Rxo1, that conditions a resistance reaction to a diverse collection of pathogen strains. Surprisingly, Rxo1 also controls resistance to the unrelated pathogen Burkholderia andropogonis, which causes bacterial stripe of sorghum and maize. The same gene thus controls resistance reactions to both pathogens and nonpathogens of maize. Rxo1 has a nucleotide-binding site-leucine-rich repeat structure, similar to many previously identified R genes. Most importantly, Rxo1 functions after transfer as a transgene to rice, demonstrating the feasibility of nonhost R gene transfer between cereals and providing a valuable tool for controlling bacterial streak disease.

  6. traits and resistance to maize streak virus disease in kenya

    African Journals Online (AJOL)

    African Crop Science Journal, Vol. 14. No. 4, pp. ... Kenya Agricultural Research Institute, Muguga-South, P.O. Box 30148, Nairobi, Kenya .... streak disease has been identified in various maize recycling and development of pure-lines at.

  7. Airborne hyperspectral observations of surface and cloud directional reflectivity using a commercial digital camera

    Directory of Open Access Journals (Sweden)

    A. Ehrlich

    2012-04-01

    Full Text Available Spectral radiance measurements by a digital single-lens reflex camera were used to derive the directional reflectivity of clouds and different surfaces in the Arctic. The camera has been calibrated radiometrically and spectrally to provide accurate radiance measurements with high angular resolution. A comparison with spectral radiance measurements with the Spectral Modular Airborne Radiation measurement sysTem (SMART-Albedometer showed an agreement within the uncertainties of both instruments (6% for both. The directional reflectivity in terms of the hemispherical directional reflectance factor (HDRF was obtained for sea ice, ice-free ocean and clouds. The sea ice, with an albedo of ρ = 0.96 (at 530 nm wavelength, showed an almost isotropic HDRF, while sun glint was observed for the ocean HDRF (ρ = 0.12. For the cloud observations with ρ = 0.62, the cloudbow – a backscatter feature typically for scattering by liquid water droplets – was covered by the camera. For measurements above heterogeneous stratocumulus clouds, the required number of images to obtain a mean HDRF that clearly exhibits the cloudbow has been estimated at about 50 images (10 min flight time. A representation of the HDRF as a function of the scattering angle only reduces the image number to about 10 (2 min flight time.

    The measured cloud and ocean HDRF have been compared to radiative transfer simulations. The ocean HDRF simulated with the observed surface wind speed of 9 m s−1 agreed best with the measurements. For the cloud HDRF, the best agreement was obtained by a broad and weak cloudbow simulated with a cloud droplet effective radius of Reff = 4 μm. This value agrees with the particle sizes derived from in situ measurements and retrieved from the spectral radiance of the SMART-Albedometer.

  8. Observation of the substructure in the electron bunch on the ACO storage ring

    International Nuclear Information System (INIS)

    Bergher, M.; Velghe, M.; Mialocq, J.P.

    1984-09-01

    In the future, one interesting point of the SRFEL at Orsay will be the microtemporal analysis of the laser beam correlated with that of the electron bunch. In a first time, we have only analysed the temporal structure of the electron bunch with an Electrophotonic streak camera. The first results seem to indicate that the bunch is not an homogeneous bunch but presents a substructure. We discuss with details this data

  9. High speed photography, videography, and photonics III; Proceedings of the Meeting, San Diego, CA, August 22, 23, 1985

    Science.gov (United States)

    Ponseggi, B. G. (Editor); Johnson, H. C. (Editor)

    1985-01-01

    Papers are presented on the picosecond electronic framing camera, photogrammetric techniques using high-speed cineradiography, picosecond semiconductor lasers for characterizing high-speed image shutters, the measurement of dynamic strain by high-speed moire photography, the fast framing camera with independent frame adjustments, design considerations for a data recording system, and nanosecond optical shutters. Consideration is given to boundary-layer transition detectors, holographic imaging, laser holographic interferometry in wind tunnels, heterodyne holographic interferometry, a multispectral video imaging and analysis system, a gated intensified camera, a charge-injection-device profile camera, a gated silicon-intensified-target streak tube and nanosecond-gated photoemissive shutter tubes. Topics discussed include high time-space resolved photography of lasers, time-resolved X-ray spectrographic instrumentation for laser studies, a time-resolving X-ray spectrometer, a femtosecond streak camera, streak tubes and cameras, and a short pulse X-ray diagnostic development facility.

  10. Cassava brown streak disease effects on leaf metabolites and ...

    African Journals Online (AJOL)

    Cassava brown streak disease effects on leaf metabolites and pigment accumulation. ... Total reducing sugar and starch content also dropped significantly (-30 and -60%, respectively), much as NASE 14 maintained a relatively higher amount of carbohydrates. Leaf protein levels were significantly reduced at a rate of 0.07 ...

  11. Reconstruction in PET cameras with irregular sampling and depth of interaction capability

    International Nuclear Information System (INIS)

    Virador, P.R.G.; Moses, W.W.; Huesman, R.H.

    1998-01-01

    The authors present 2D reconstruction algorithms for a rectangular PET camera capable of measuring depth of interaction (DOI). The camera geometry leads to irregular radial and angular sampling of the tomographic data. DOI information increases sampling density, allowing the use of evenly spaced quarter-crystal width radial bins with minimal interpolation of irregularly spaced data. In the regions where DOI does not increase sampling density (chords normal to crystal faces), fine radial sinogram binning leads to zero efficiency bins if uniform angular binning is used. These zero efficiency sinogram bins lead to streak artifacts if not corrected. To minimize these unnormalizable sinogram bins the authors use two angular binning schemes: Fixed Width and Natural Width. Fixed Width uses a fixed angular width except in the problem regions where appropriately chosen widths are applied. Natural Width uses angle widths which are derived from intrinsic detector sampling. Using a modified filtered-backprojection algorithm to accommodate these angular binning schemes, the authors reconstruct artifact free images with nearly isotropic and position independent spatial resolution. Results from Monte Carlo data indicate that they have nearly eliminated image degradation due to crystal penetration

  12. Observation of GEO Satellite Above Thailand’s Sky

    Science.gov (United States)

    Kasonsuwan, K.; Wannawichian, S.; Kirdkao, T.

    2017-09-01

    The direct observations of Geostationary Orbit (GEO) satellites above Thailand’s sky by 0.7-meters telescope were proceeded at Inthanon Mt., Chiang Mai, Thailand. The observation took place at night with Sidereal Stare Mode (SSM). With this observing mode, the moving object will appear as a streak. The star identification for image calibration is based on (1) a star catalogue, (2) the streak detection of the satellite using the software and (3) the extraction of the celestial coordinate of the satellite as a predicted position. Finally, the orbital elements for GEO satellites were calculated.

  13. Quantitative trait loci for resistance to maize streak virus disease in ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-07-18

    Jul 18, 2008 ... African Journal of Biotechnology Vol. ... development ... Biotechnology Center, Kenya Agricultural Research Institute, P.O. Box 58711-00200, Nairobi, ... Maize streak virus disease is an important disease of maize in Kenya.

  14. Persistence of Smectic-A Oily Streaks into the Nematic Phase by UV Irradiation of Reactive Mesogens

    Directory of Open Access Journals (Sweden)

    Ines Gharbi

    2017-12-01

    Full Text Available Thin smectic liquid crystal films with competing boundary conditions (planar and homeotropic at opposing surfaces form well-known striated structures known as “oily streaks”, which are a series of hemicylindrical caps that run perpendicular to the easy axis of the planar substrate. The streaks vanish on heating into the nematic phase, where the film becomes uniform and exhibits hybrid alignment. On adding sufficient reactive mesogen and polymerizing, the oily streak texture is maintained on heating through the entire nematic phase until reaching the bulk isotropic phase, above which the texture vanishes. Depending on the liquid crystal thickness, the oily streak structure may be retrieved after cooling, which demonstrates the strong impact of the polymer backbone on the liquid crystal texture. Polarizing optical, atomic force, and scanning electron microscopy data are presented.

  15. VUV testing of science cameras at MSFC: QE measurement of the CLASP flight cameras

    Science.gov (United States)

    Champey, P.; Kobayashi, K.; Winebarger, A.; Cirtain, J.; Hyde, D.; Robertson, B.; Beabout, B.; Beabout, D.; Stewart, M.

    2015-08-01

    The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint MSFC, National Astronomical Observatory of Japan (NAOJ), Instituto de Astrofisica de Canarias (IAC) and Institut D'Astrophysique Spatiale (IAS) sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512 × 512 detector, dual channel analog readout and an internally mounted cold block. At the flight CCD temperature of -20C, the CLASP cameras exceeded the low-noise performance requirements (UV, EUV and X-ray science cameras at MSFC.

  16. Picosecond x-ray streak camera studies

    International Nuclear Information System (INIS)

    Kasyanov, Yu.S.; Malyutin, A.A.; Richardson, M.C.; Chevokin, V.K.

    1975-01-01

    Some initial results of direct measurement of picosecond x-ray emission from laser-produced plasmas are presented. A PIM-UMI 93 image converter tube, incorporating an x-ray sensitive photocathode, linear deflection, and three stages of image amplification was used to analyse the x-ray radiation emanating from plasmas produced from solid Ti targets by single high-intensity picosecond laser pulses. From such plasmas, the x-ray emission typically persisted for times of 60psec. However, it is shown that this detection system should be capable of resolving x-ray phenomena of much shorter duration. (author)

  17. International Congress on High Speed Photography and Photonics, 17th, Pretoria, Republic of South Africa, Sept. 1-5, 1986, Proceedings. Volumes 1 & 2

    Science.gov (United States)

    McDowell, M. W.; Hollingworth, D.

    1986-01-01

    The present conference discusses topics in mining applications of high speed photography, ballistic, shock wave and detonation studies employing high speed photography, laser and X-ray diagnostics, biomechanical photography, millisec-microsec-nanosec-picosec-femtosec photographic methods, holographic, schlieren, and interferometric techniques, and videography. Attention is given to such issues as the pulse-shaping of ultrashort optical pulses, the performance of soft X-ray streak cameras, multiple-frame image tube operation, moire-enlargement motion-raster photography, two-dimensional imaging with tomographic techniques, photochron TV streak cameras, and streak techniques in detonics.

  18. Inactivation of the Huntington's disease gene (Hdh impairs anterior streak formation and early patterning of the mouse embryo

    Directory of Open Access Journals (Sweden)

    Conlon Ronald A

    2005-08-01

    Full Text Available Abstract Background Huntingtin, the HD gene encoded protein mutated by polyglutamine expansion in Huntington's disease, is required in extraembryonic tissues for proper gastrulation, implicating its activities in nutrition or patterning of the developing embryo. To test these possibilities, we have used whole mount in situ hybridization to examine embryonic patterning and morphogenesis in homozygous Hdhex4/5 huntingtin deficient embryos. Results In the absence of huntingtin, expression of nutritive genes appears normal but E7.0–7.5 embryos exhibit a unique combination of patterning defects. Notable are a shortened primitive streak, absence of a proper node and diminished production of anterior streak derivatives. Reduced Wnt3a, Tbx6 and Dll1 expression signify decreased paraxial mesoderm and reduced Otx2 expression and lack of headfolds denote a failure of head development. In addition, genes initially broadly expressed are not properly restricted to the posterior, as evidenced by the ectopic expression of Nodal, Fgf8 and Gsc in the epiblast and T (Brachyury and Evx1 in proximal mesoderm derivatives. Despite impaired posterior restriction and anterior streak deficits, overall anterior/posterior polarity is established. A single primitive streak forms and marker expression shows that the anterior epiblast and anterior visceral endoderm (AVE are specified. Conclusion Huntingtin is essential in the early patterning of the embryo for formation of the anterior region of the primitive streak, and for down-regulation of a subset of dynamic growth and transcription factor genes. These findings provide fundamental starting points for identifying the novel cellular and molecular activities of huntingtin in the extraembryonic tissues that govern normal anterior streak development. This knowledge may prove to be important for understanding the mechanism by which the dominant polyglutamine expansion in huntingtin determines the loss of neurons in

  19. Inactivation of the Huntington's disease gene (Hdh) impairs anterior streak formation and early patterning of the mouse embryo.

    Science.gov (United States)

    Woda, Juliana M; Calzonetti, Teresa; Hilditch-Maguire, Paige; Duyao, Mabel P; Conlon, Ronald A; MacDonald, Marcy E

    2005-08-18

    Huntingtin, the HD gene encoded protein mutated by polyglutamine expansion in Huntington's disease, is required in extraembryonic tissues for proper gastrulation, implicating its activities in nutrition or patterning of the developing embryo. To test these possibilities, we have used whole mount in situ hybridization to examine embryonic patterning and morphogenesis in homozygous Hdh(ex4/5) huntingtin deficient embryos. In the absence of huntingtin, expression of nutritive genes appears normal but E7.0-7.5 embryos exhibit a unique combination of patterning defects. Notable are a shortened primitive streak, absence of a proper node and diminished production of anterior streak derivatives. Reduced Wnt3a, Tbx6 and Dll1 expression signify decreased paraxial mesoderm and reduced Otx2 expression and lack of headfolds denote a failure of head development. In addition, genes initially broadly expressed are not properly restricted to the posterior, as evidenced by the ectopic expression of Nodal, Fgf8 and Gsc in the epiblast and T (Brachyury) and Evx1 in proximal mesoderm derivatives. Despite impaired posterior restriction and anterior streak deficits, overall anterior/posterior polarity is established. A single primitive streak forms and marker expression shows that the anterior epiblast and anterior visceral endoderm (AVE) are specified. Huntingtin is essential in the early patterning of the embryo for formation of the anterior region of the primitive streak, and for down-regulation of a subset of dynamic growth and transcription factor genes. These findings provide fundamental starting points for identifying the novel cellular and molecular activities of huntingtin in the extraembryonic tissues that govern normal anterior streak development. This knowledge may prove to be important for understanding the mechanism by which the dominant polyglutamine expansion in huntingtin determines the loss of neurons in Huntington's disease.

  20. Visceral endoderm and the primitive streak interact to build the fetal-placental interface of the mouse gastrula.

    Science.gov (United States)

    Rodriguez, Adriana M; Downs, Karen M

    2017-12-01

    Hypoblast/visceral endoderm assists in amniote nutrition, axial positioning and formation of the gut. Here, we provide evidence, currently limited to humans and non-human primates, that hypoblast is a purveyor of extraembryonic mesoderm in the mouse gastrula. Fate mapping a unique segment of axial extraembryonic visceral endoderm associated with the allantoic component of the primitive streak, and referred to as the "AX", revealed that visceral endoderm supplies the placentae with extraembryonic mesoderm. Exfoliation of the AX was dependent upon contact with the primitive streak, which modulated Hedgehog signaling. Resolution of the AX's epithelial-to-mesenchymal transition (EMT) by Hedgehog shaped the allantois into its characteristic projectile and individualized placental arterial vessels. A unique border cell separated the delaminating AX from the yolk sac blood islands which, situated beyond the limit of the streak, were not formed by an EMT. Over time, the AX became the hindgut lip, which contributed extensively to the posterior interface, including both embryonic and extraembryonic tissues. The AX, in turn, imparted antero-posterior (A-P) polarity on the primitive streak and promoted its elongation and differentiation into definitive endoderm. Results of heterotopic grafting supported mutually interactive functions of the AX and primitive streak, showing that together, they self-organized into a complete version of the fetal-placental interface, forming an elongated structure that exhibited A-P polarity and was composed of the allantois, an AX-derived rod-like axial extension reminiscent of the embryonic notochord, the placental arterial vasculature and visceral endoderm/hindgut. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  1. Nighttime Near Infrared Observations of Augustine Volcano Jan-Apr, 2006 Recorded With a Small Astronomical CCD Camera

    Science.gov (United States)

    Sentman, D.; McNutt, S.; Reyes, C.; Stenbaek-Nielsen, H.; Deroin, N.

    2006-12-01

    Nighttime observations of Augustine Volcano were made during Jan-Apr, 2006 using a small, unfiltered, astronomical CCD camera operating from Homer, Alaska. Time-lapse images of the volcano were made looking across the open water of the Cook Inlet over a slant range of ~105 km. A variety of volcano activities were observed that originated in near-infrared (NIR) 0.9-1.1 micron emissions, which were detectable at the upper limit of the camera passband but were otherwise invisible to the naked eye. These activities included various types of steam releases, pyroclastic flows, rockfalls and debris flows that were correlated very closely with seismic measurements made from instruments located within 4 km on the volcanic island. Specifically, flow events to the east (towards the camera) produced high amplitudes on the eastern seismic stations and events presumably to the west were stronger on western stations. The ability to detect nighttime volcanic emissions in the NIR over large horizontal distances using standard silicon CCD technology, even in the presence of weak intervening fog, came as a surprise, and is due to a confluence of several mutually reinforcing factors: (1) Hot enough (~1000K) thermal emissions from the volcano that the short wavelength portion of the Planck radiation curve overlaps the upper portions (0.9-1.1 micron) of the sensitivity of the silicon CCD detectors, and could thus be detected, (2) The existence of several atmospheric transmission windows within the NIR passband of the camera for the emissions to propagate with relatively small attenuation through more than 10 atmospheres, and (3) in the case of fog, forward Mie scattering.

  2. Significance and transmission of maize streak virus disease in Africa ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-12-29

    Dec 29, 2008 ... soil nutrients, altitude and temperature on the biology of maize streak virus (MSV) / vector populations is discussed. ... status of maize host plants and its effects on population dynamics of Cicadulina mbila Naudé. (Homoptera: ..... time necessary for the leafhopper to reach the mesophyll of the leaf and ingest ...

  3. Target 3-D reconstruction of streak tube imaging lidar based on Gaussian fitting

    Science.gov (United States)

    Yuan, Qingyu; Niu, Lihong; Hu, Cuichun; Wu, Lei; Yang, Hongru; Yu, Bing

    2018-02-01

    Streak images obtained by the streak tube imaging lidar (STIL) contain the distance-azimuth-intensity information of a scanned target, and a 3-D reconstruction of the target can be carried out through extracting the characteristic data of multiple streak images. Significant errors will be caused in the reconstruction result by the peak detection method due to noise and other factors. So as to get a more precise 3-D reconstruction, a peak detection method based on Gaussian fitting of trust region is proposed in this work. Gaussian modeling is performed on the returned wave of single time channel of each frame, then the modeling result which can effectively reduce the noise interference and possesses a unique peak could be taken as the new returned waveform, lastly extracting its feature data through peak detection. The experimental data of aerial target is for verifying this method. This work shows that the peak detection method based on Gaussian fitting reduces the extraction error of the feature data to less than 10%; utilizing this method to extract the feature data and reconstruct the target make it possible to realize the spatial resolution with a minimum 30 cm in the depth direction, and improve the 3-D imaging accuracy of the STIL concurrently.

  4. MR imaging of medullary streaks in osteosclerosis: a case report

    International Nuclear Information System (INIS)

    Lee, Hak Soo; Joo, Kyung Bin; Park, Tae Soo; Song, Ho Taek; Kim, Yong Soo; Park, Dong Woo; Park, Choong Ki

    2000-01-01

    We present a case of medullary sclerosis of the appendicular skeleton in a patient with chronic renal insufficiency for whom MR imaging findings were characteristic. T1- and T2-weighted MR images showed multiple vertical lines (medullary streaks) of low signal intensity in the metaphyses and diaphyses of the distal femur and proximal tibia

  5. A compact low cost “master–slave” double crystal monochromator for x-ray cameras calibration of the Laser MégaJoule Facility

    Energy Technology Data Exchange (ETDEWEB)

    Hubert, S., E-mail: sebastien.hubert@cea.fr; Prévot, V.

    2014-12-21

    The Alternative Energies and Atomic Energy Commission (CEA-CESTA, France) built a specific double crystal monochromator (DCM) to perform calibration of x-ray cameras (CCD, streak and gated cameras) by means of a multiple anode diode type x-ray source for the MégaJoule Laser Facility. This DCM, based on pantograph geometry, was specifically modeled to respond to relevant engineering constraints and requirements. The major benefits are mechanical drive of the second crystal on the first one, through a single drive motor, as well as compactness of the entire device. Designed for flat beryl or Ge crystals, this DCM covers the 0.9–10 keV range of our High Energy X-ray Source. In this paper we present the mechanical design of the DCM, its features quantitatively measured and its calibration to finally provide monochromatized spectra displaying spectral purities better than 98%.

  6. Time response characteristics of X-ray detector system on Silex-Ⅰ laser facility

    International Nuclear Information System (INIS)

    Yi Rongqing; He Xiao'an; Li Hang; Du Huabing; Zhang Haiying; Cao Zhurong

    2013-01-01

    On the Silex-Ⅰ laser facility, the time response characteristics of XRD detector were studied. A laser with a pulse of 32 fs and a wavelength of 800 nm was used to irradiate a plane Au target. X-ray calibrated method of time of exposure X-ray framing camera and time resolution of X-ray streak camera was explored. The time response characteristics of XRD detector and time process of X-ray emission were obtained from experiment. We obtained X-ray calibration method of time of exposure X-ray framing camera and time resolution of X-ray streak camera. (authors)

  7. A telescopic cinema sound camera for observing high altitude aerospace vehicles

    Science.gov (United States)

    Slater, Dan

    2014-09-01

    Rockets and other high altitude aerospace vehicles produce interesting visual and aural phenomena that can be remotely observed from long distances. This paper describes a compact, passive and covert remote sensing system that can produce high resolution sound movies at >100 km viewing distances. The telescopic high resolution camera is capable of resolving and quantifying space launch vehicle dynamics including plume formation, staging events and payload fairing jettison. Flight vehicles produce sounds and vibrations that modulate the local electromagnetic environment. These audio frequency modulations can be remotely sensed by passive optical and radio wave detectors. Acousto-optic sensing methods were primarily used but an experimental radioacoustic sensor using passive micro-Doppler radar techniques was also tested. The synchronized combination of high resolution flight vehicle imagery with the associated vehicle sounds produces a cinema like experience that that is useful in both an aerospace engineering and a Hollywood film production context. Examples of visual, aural and radar observations of the first SpaceX Falcon 9 v1.1 rocket launch are shown and discussed.

  8. SPECKLE CAMERA OBSERVATIONS FOR THE NASA KEPLER MISSION FOLLOW-UP PROGRAM

    International Nuclear Information System (INIS)

    Howell, Steve B.; Everett, Mark E.; Sherry, William; Horch, Elliott; Ciardi, David R.

    2011-01-01

    We present the first results from a speckle imaging survey of stars classified as candidate exoplanet host stars discovered by the Kepler mission. We use speckle imaging to search for faint companions or closely aligned background stars that could contribute flux to the Kepler light curves of their brighter neighbors. Background stars are expected to contribute significantly to the pool of false positive candidate transiting exoplanets discovered by the Kepler mission, especially in the case that the faint neighbors are eclipsing binary stars. Here, we describe our Kepler follow-up observing program, the speckle imaging camera used, our data reduction, and astrometric and photometric performance. Kepler stars range from R = 8 to 16 and our observations attempt to provide background non-detection limits 5-6 mag fainter and binary separations of ∼0.05-2.0 arcsec. We present data describing the relative brightness, separation, and position angles for secondary sources, as well as relative plate limits for non-detection of faint nearby stars around each of 156 target stars. Faint neighbors were found near 10 of the stars.

  9. A method of camera calibration in the measurement process with reference mark for approaching observation space target

    Science.gov (United States)

    Zhang, Hua; Zeng, Luan

    2017-11-01

    Binocular stereoscopic vision can be used for space-based space targets near observation. In order to solve the problem that the traditional binocular vision system cannot work normally after interference, an online calibration method of binocular stereo measuring camera with self-reference is proposed. The method uses an auxiliary optical imaging device to insert the image of the standard reference object into the edge of the main optical path and image with the target on the same focal plane, which is equivalent to a standard reference in the binocular imaging optical system; When the position of the system and the imaging device parameters are disturbed, the image of the standard reference will change accordingly in the imaging plane, and the position of the standard reference object does not change. The camera's external parameters can be re-calibrated by the visual relationship of the standard reference object. The experimental results show that the maximum mean square error of the same object can be reduced from the original 72.88mm to 1.65mm when the right camera is deflected by 0.4 degrees and the left camera is high and low with 0.2° rotation. This method can realize the online calibration of binocular stereoscopic vision measurement system, which can effectively improve the anti - jamming ability of the system.

  10. Fast imaging applications in the Nuclear Test Program

    International Nuclear Information System (INIS)

    Lear, R.

    1983-01-01

    Applications of fast imaging employ both streak cameras and fast framing techniques. Image intensifier tubes are gated to provide fast two-dimensional shutters of 2 to 3 ns duration with shatter ratios of greater than 10 6 and resolution greater than 10 4 pixels. Shutters of less than 1 ns have been achieved with experimental tubes. Characterization data demonstrate the importance of tube and pulser design. Streak cameras are used to simultaneously record temporal and intensity information from up to 200 spatial points. Streak cameras are combined with remote readout for downhole uses and are coupled to fiber optic cables for uphole uses. Optical wavelength multiplexing is being studied as a means of compressing additional image data onto optical fibers. Performance data demonstrate trade-offs between image resolution and system sensitivity

  11. About possibility of temperature trace observing on the human skin using commercially available IR camera

    Science.gov (United States)

    Trofimov, Vyacheslav A.; Trofimov, Vladislav V.; Shestakov, Ivan L.; Blednov, Roman G.

    2016-09-01

    One of urgent security problems is a detection of objects placed inside the human body. Obviously, for safety reasons one cannot use X-rays for such object detection widely and often. Three years ago, we have demonstrated principal possibility to see a temperature trace, induced by food eating or water drinking, on the human body skin by using a passive THz camera. However, this camera is very expensive. Therefore, for practice it will be very convenient if one can use the IR camera for this purpose. In contrast to passive THz camera using, the IR camera does not allow to see the object under clothing, if an image, produced by this camera, is used directly. Of course, this is a big disadvantage for a security problem solution based on the IR camera using. To overcome this disadvantage we develop novel approach for computer processing of IR camera images. It allows us to increase a temperature resolution of IR camera as well as increasing of human year effective susceptibility. As a consequence of this, a possibility for seeing of a human body temperature changing through clothing appears. We analyze IR images of a person, which drinks water and eats chocolate. We follow a temperature trace on human body skin, caused by changing of temperature inside the human body. Some experiments were made with measurements of a body temperature covered by T-shirt. Shown results are very important for the detection of forbidden objects, cancelled inside the human body, by using non-destructive control without using X-rays.

  12. An ebCMOS camera system for marine bioluminescence observation: The LuSEApher prototype

    Energy Technology Data Exchange (ETDEWEB)

    Dominjon, A., E-mail: a.dominjon@ipnl.in2p3.fr [CNRS/IN2P3, Institut de Physique Nucleaire de Lyon, Villeurbanne F-69622 (France); Ageron, M. [CNRS/IN2P3, Centre de Physique des Particules de Marseille, Marseille, F-13288 (France); Barbier, R. [CNRS/IN2P3, Institut de Physique Nucleaire de Lyon, Villeurbanne F-69622 (France); Universite de Lyon, Universite Lyon 1, Lyon F-69003 (France); Billault, M.; Brunner, J. [CNRS/IN2P3, Centre de Physique des Particules de Marseille, Marseille, F-13288 (France); Cajgfinger, T. [CNRS/IN2P3, Institut de Physique Nucleaire de Lyon, Villeurbanne F-69622 (France); Universite de Lyon, Universite Lyon 1, Lyon F-69003 (France); Calabria, P. [CNRS/IN2P3, Institut de Physique Nucleaire de Lyon, Villeurbanne F-69622 (France); Chabanat, E. [CNRS/IN2P3, Institut de Physique Nucleaire de Lyon, Villeurbanne F-69622 (France); Universite de Lyon, Universite Lyon 1, Lyon F-69003 (France); Chaize, D.; Doan, Q.T.; Guerin, C.; Houles, J.; Vagneron, L. [CNRS/IN2P3, Institut de Physique Nucleaire de Lyon, Villeurbanne F-69622 (France)

    2012-12-11

    The ebCMOS camera, called LuSEApher, is a marine bioluminescence recorder device adapted to extreme low light level. This prototype is based on the skeleton of the LUSIPHER camera system originally developed for fluorescence imaging. It has been installed at 2500 m depth off the Mediterranean shore on the site of the ANTARES neutrino telescope. The LuSEApher camera is mounted on the Instrumented Interface Module connected to the ANTARES network for environmental science purposes (European Seas Observatory Network). The LuSEApher is a self-triggered photo detection system with photon counting ability. The presentation of the device is given and its performances such as the single photon reconstruction, noise performances and trigger strategy are presented. The first recorded movies of bioluminescence are analyzed. To our knowledge, those types of events have never been obtained with such a sensitivity and such a frame rate. We believe that this camera concept could open a new window on bioluminescence studies in the deep sea.

  13. Time-resolved brightness measurements by streaking

    Science.gov (United States)

    Torrance, Joshua S.; Speirs, Rory W.; McCulloch, Andrew J.; Scholten, Robert E.

    2018-03-01

    Brightness is a key figure of merit for charged particle beams, and time-resolved brightness measurements can elucidate the processes involved in beam creation and manipulation. Here we report on a simple, robust, and widely applicable method for the measurement of beam brightness with temporal resolution by streaking one-dimensional pepperpots, and demonstrate the technique to characterize electron bunches produced from a cold-atom electron source. We demonstrate brightness measurements with 145 ps temporal resolution and a minimum resolvable emittance of 40 nm rad. This technique provides an efficient method of exploring source parameters and will prove useful for examining the efficacy of techniques to counter space-charge expansion, a critical hurdle to achieving single-shot imaging of atomic scale targets.

  14. Growth and Characterization of Nanostructured Glass Ceramic Scintillators for Miniature High-Energy Radiation Sensors

    Science.gov (United States)

    2013-10-01

    rise time was resolved using Kerr gating technique with 8 ps resolution. Spectro -temporal dynamics was resolved using streak camera and tunable pump...mol% CeF3 doped glass under UV light irradiation). Fig. 5. Radioluminescence (RL) spectra of all the CeF3 doped glasses...technique with 8 ps resolution. Spectro -temporal dynamics was resolved using streak camera and tunable pump at second/third harmonic (400/267nm) and XUV

  15. DuOCam: A Two-Channel Camera for Simultaneous Photometric Observations of Stellar Clusters

    Science.gov (United States)

    Maier, Erin R.; Witt, Emily; Depoy, Darren L.; Schmidt, Luke M.

    2017-01-01

    We have designed the Dual Observation Camera (DuOCam), which uses commercial, off-the-shelf optics to perform simultaneous photometric observations of astronomical objects at red and blue wavelengths. Collected light enters DuOCam’s optical assembly, where it is collimated by a negative doublet lens. It is then separated by a 45 degree blue dichroic filter (transmission bandpass: 530 - 800 nm, reflection bandpass: 400 - 475 nm). Finally, the separated light is focused by two identical positive doublet lenses onto two independent charge-coupled devices (CCDs), the SBIG ST-8300M and the SBIG STF-8300M. This optical assembly converts the observing telescope to an f/11 system, which balances maximum field of view with optimum focus. DuOCam was commissioned on the McDonald Observatory 0.9m, f/13.5 telescope from July 21st - 24th, 2016. Observations of three globular and three open stellar clusters were carried out. The resulting data were used to construct R vs. B-R color magnitude diagrams for a selection of the observed clusters. The diagrams display the characteristic evolutionary track for a stellar cluster, including the main sequence and main sequence turn-off.

  16. Initial inflight calibration for Hayabusa2 optical navigation camera (ONC) for science observations of asteroid Ryugu

    Science.gov (United States)

    Suzuki, H.; Yamada, M.; Kouyama, T.; Tatsumi, E.; Kameda, S.; Honda, R.; Sawada, H.; Ogawa, N.; Morota, T.; Honda, C.; Sakatani, N.; Hayakawa, M.; Yokota, Y.; Yamamoto, Y.; Sugita, S.

    2018-01-01

    Hayabusa2, the first sample return mission to a C-type asteroid was launched by the Japan Aerospace Exploration Agency (JAXA) on December 3, 2014 and will arrive at the asteroid in the middle of 2018 to collect samples from its surface, which may contain both hydrated minerals and organics. The optical navigation camera (ONC) system on board the Hayabusa2 consists of three individual framing CCD cameras, ONC-T for a telescopic nadir view, ONC-W1 for a wide-angle nadir view, and ONC-W2 for a wide-angle slant view will be used to observe the surface of Ryugu. The cameras will be used to measure the global asteroid shape, local morphologies, and visible spectroscopic properties. Thus, image data obtained by ONC will provide essential information to select landing (sampling) sites on the asteroid. This study reports the results of initial inflight calibration based on observations of Earth, Mars, Moon, and stars to verify and characterize the optical performance of the ONC, such as flat-field sensitivity, spectral sensitivity, point-spread function (PSF), distortion, and stray light of ONC-T, and distortion for ONC-W1 and W2. We found some potential problems that may influence our science observations. This includes changes in sensitivity of flat fields for all bands from those that were measured in the pre-flight calibration and existence of a stray light that arises under certain conditions of spacecraft attitude with respect to the sun. The countermeasures for these problems were evaluated by using data obtained during initial in-flight calibration. The results of our inflight calibration indicate that the error of spectroscopic measurements around 0.7 μm using 0.55, 0.70, and 0.86 μm bands of the ONC-T can be lower than 0.7% after these countermeasures and pixel binning. This result suggests that our ONC-T would be able to detect typical strength (∼3%) of the serpentine absorption band often found on CM chondrites and low albedo asteroids with ≥ 4

  17. A high spatio-temporal resolution optical pyrometer at the ORION laser facility.

    Science.gov (United States)

    Floyd, Emma; Gumbrell, Edward T; Fyrth, Jim; Luis, James D; Skidmore, Jonathan W; Patankar, Siddharth; Giltrap, Samuel; Smith, Roland

    2016-11-01

    A streaked pyrometer has been designed to measure the temperature of ≈100 μm diameter heated targets in the warm dense matter region. The diagnostic has picosecond time resolution. Spatial resolution is limited by the streak camera to 4 μm in one dimension; the imaging system has superior resolution of 1 μm. High light collection efficiency means that the diagnostic can transmit a measurable quantity of thermal emission at temperatures as low as 1 eV to the detector. This is achieved through the use of an f/1.4 objective, and a minimum number of reflecting and refracting surfaces to relay the image over 8 m with no vignetting over a 0.4 mm field of view with 12.5× magnification. All the system optics are highly corrected, to allow imaging with minimal aberrations over a broad spectral range. The detector is a highly sensitive Axis Photonique streak camera with a P820PSU streak tube. For the first time, two of these cameras have been absolutely calibrated at 1 ns and 2 ns sweep speeds under full operational conditions and over 8 spectral bands between 425 nm and 650 nm using a high-stability picosecond white light source. Over this range the cameras had a response which varied between 47 ± 8 and 14 ± 4 photons/count. The calibration of the optical imaging system makes absolute temperature measurements possible. Color temperature measurements are also possible due to the wide spectral range over which the system is calibrated; two different spectral bands can be imaged onto different parts of the photocathode of the same streak camera.

  18. Oct4 is required ~E7.5 for proliferation in the primitive streak.

    Directory of Open Access Journals (Sweden)

    Brian DeVeale

    2013-11-01

    Full Text Available Oct4 is a widely recognized pluripotency factor as it maintains Embryonic Stem (ES cells in a pluripotent state, and, in vivo, prevents the inner cell mass (ICM in murine embryos from differentiating into trophectoderm. However, its function in somatic tissue after this developmental stage is not well characterized. Using a tamoxifen-inducible Cre recombinase and floxed alleles of Oct4, we investigated the effect of depleting Oct4 in mouse embryos between the pre-streak and headfold stages, ~E6.0-E8.0, when Oct4 is found in dynamic patterns throughout the embryonic compartment of the mouse egg cylinder. We found that depletion of Oct4 ~E7.5 resulted in a severe phenotype, comprised of craniorachischisis, random heart tube orientation, failed turning, defective somitogenesis and posterior truncation. Unlike in ES cells, depletion of the pluripotency factors Sox2 and Oct4 after E7.0 does not phenocopy, suggesting that ~E7.5 Oct4 is required within a network that is altered relative to the pluripotency network. Oct4 is not required in extraembryonic tissue for these processes, but is required to maintain cell viability in the embryo and normal proliferation within the primitive streak. Impaired expansion of the primitive streak occurs coincident with Oct4 depletion ∼E7.5 and precedes deficient convergent extension which contributes to several aspects of the phenotype.

  19. VUV Testing of Science Cameras at MSFC: QE Measurement of the CLASP Flight Cameras

    Science.gov (United States)

    Champey, Patrick R.; Kobayashi, Ken; Winebarger, A.; Cirtain, J.; Hyde, D.; Robertson, B.; Beabout, B.; Beabout, D.; Stewart, M.

    2015-01-01

    The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512x512 detector, dual channel analog readout electronics and an internally mounted cold block. At the flight operating temperature of -20 C, the CLASP cameras achieved the low-noise performance requirements (less than or equal to 25 e- read noise and greater than or equal to 10 e-/sec/pix dark current), in addition to maintaining a stable gain of approximately equal to 2.0 e-/DN. The e2v CCD57-10 detectors were coated with Lumogen-E to improve quantum efficiency (QE) at the Lyman- wavelength. A vacuum ultra-violet (VUV) monochromator and a NIST calibrated photodiode were employed to measure the QE of each camera. Four flight-like cameras were tested in a high-vacuum chamber, which was configured to operate several tests intended to verify the QE, gain, read noise, dark current and residual non-linearity of the CCD. We present and discuss the QE measurements performed on the CLASP cameras. We also discuss the high-vacuum system outfitted for testing of UV and EUV science cameras at MSFC.

  20. Effects of Hot Streak and Phantom Cooling on Heat Transfer in a Cooled Turbine Stage Including Particulate Deposition

    Energy Technology Data Exchange (ETDEWEB)

    Bons, Jeffrey [The Ohio State Univ., Columbus, OH (United States); Ameri, Ali [The Ohio State Univ., Columbus, OH (United States)

    2016-01-08

    The objective of this research effort was to develop a validated computational modeling capability for the characterization of the effects of hot streaks and particulate deposition on the heat load of modern gas turbines. This was accomplished with a multi-faceted approach including analytical, experimental, and computational components. A 1-year no cost extension request was approved for this effort, so the total duration was 4 years. The research effort succeeded in its ultimate objective by leveraging extensive experimental deposition studies complemented by computational modeling. Experiments were conducted with hot streaks, vane cooling, and combinations of hot streaks with vane cooling. These studies contributed to a significant body of corporate knowledge of deposition, in combination with particle rebound and deposition studies funded by other agencies, to provide suitable conditions for the development of a new model. The model includes the following physical phenomena: elastic deformation, plastic deformation, adhesion, and shear removal. It also incorporates material property sensitivity to temperature and tangential-normal velocity rebound cross-dependencies observed in experiments. The model is well-suited for incorporation in CFD simulations of complex gas turbine flows due to its algebraic (explicit) formulation. This report contains model predictions compared to coefficient of restitution data available in the open literature as well as deposition results from two different high temperature turbine deposition facilities. While the model comparisons with experiments are in many cases promising, several key aspects of particle deposition remain elusive. The simple phenomenological nature of the model allows for parametric dependencies to be evaluated in a straightforward manner. This effort also included the first-ever full turbine stage deposition model published in the open literature. The simulations included hot streaks and simulated vane cooling

  1. Automatic inference of geometric camera parameters and inter-camera topology in uncalibrated disjoint surveillance cameras

    Science.gov (United States)

    den Hollander, Richard J. M.; Bouma, Henri; Baan, Jan; Eendebak, Pieter T.; van Rest, Jeroen H. C.

    2015-10-01

    Person tracking across non-overlapping cameras and other types of video analytics benefit from spatial calibration information that allows an estimation of the distance between cameras and a relation between pixel coordinates and world coordinates within a camera. In a large environment with many cameras, or for frequent ad-hoc deployments of cameras, the cost of this calibration is high. This creates a barrier for the use of video analytics. Automating the calibration allows for a short configuration time, and the use of video analytics in a wider range of scenarios, including ad-hoc crisis situations and large scale surveillance systems. We show an autocalibration method entirely based on pedestrian detections in surveillance video in multiple non-overlapping cameras. In this paper, we show the two main components of automatic calibration. The first shows the intra-camera geometry estimation that leads to an estimate of the tilt angle, focal length and camera height, which is important for the conversion from pixels to meters and vice versa. The second component shows the inter-camera topology inference that leads to an estimate of the distance between cameras, which is important for spatio-temporal analysis of multi-camera tracking. This paper describes each of these methods and provides results on realistic video data.

  2. Rho kinase activity controls directional cell movements during primitive streak formation in the rabbit embryo.

    Science.gov (United States)

    Stankova, Viktoria; Tsikolia, Nikoloz; Viebahn, Christoph

    2015-01-01

    During animal gastrulation, the specification of the embryonic axes is accompanied by epithelio-mesenchymal transition (EMT), the first major change in cell shape after fertilization. EMT takes place in disparate topographical arrangements, such as the circular blastopore of amphibians, the straight primitive streak of birds and mammals or in intermediate gastrulation forms of other amniotes such as reptiles. Planar cell movements are prime candidates to arrange specific modes of gastrulation but there is no consensus view on their role in different vertebrate classes. Here, we test the impact of interfering with Rho kinase-mediated cell movements on gastrulation topography in blastocysts of the rabbit, which has a flat embryonic disc typical for most mammals. Time-lapse video microscopy, electron microscopy, gene expression and morphometric analyses of the effect of inhibiting ROCK activity showed - besides normal specification of the organizer region - a dose-dependent disruption of primitive streak formation; this disruption resulted in circular, arc-shaped or intermediate forms, reminiscent of those found in amphibians, fishes and reptiles. Our results reveal a crucial role of ROCK-controlled directional cell movements during rabbit primitive streak formation and highlight the possibility that temporal and spatial modulation of cell movements were instrumental for the evolution of gastrulation forms. © 2015. Published by The Company of Biologists Ltd.

  3. Time-resolved suprathermal x-rays

    International Nuclear Information System (INIS)

    Lee, P.H.Y.; Rosen, M.D.

    1978-01-01

    Temporally resolved x-ray spectra in the range of 1 to 20 keV have been obtained from gold disk targets irradiated by 1.06 μm laser pulses from the Argus facility. The x-ray streak camera used for the measurement has been calibrated for streak speed and dynamic range by using an air-gap Fabry-Perot etalon, and the instrument response has been calibrated using a multi-range monoenergetic x-ray source. The experimental results indicate that we are able to observe the ''hot'' x-ray temperature evolve in time and that the experimentally observed values can be qualitatively predicted by LASNEX code computations when the inhibited transport model is used

  4. Optical Photometric Observations of GEO Debris

    Science.gov (United States)

    Seitzer, Patrick; Rodriquez-Cowardin, Heather M.; Barker, Edwin S.; Abercromby, Kira J.; Kelecy, Thomas M.; Horstman, Matt

    2010-01-01

    We report on a continuing program of optical photometric measurements of faint orbital debris at geosynchronous Earth orbit (GEO). These observations can be compared with laboratory studies of actual spacecraft materials in an effort to determine what the faint debris at GEO may be. We have optical observations from Cerro Tololo Inter-American Observatory (CTIO) in Chile of two samples of debris: 1. GEO objects discovered in a survey with the University of Michigan's 0.6-m aperture Curtis-Schmidt telescope MODEST (for Michigan Orbital DEbris Survey Telescope), and then followed up in real-time with the CTIO/SMARTS 0.9-m for orbits and photometry. Our goal is to determine 6 parameter orbits and measure colors for all objects fainter than R = 15 t11 magnitude that are discovered in the MODEST survey. 2. A smaller sample of high area to mass ratio (AMR) objects discovered independently, and acquired using predictions from orbits derived from independent tracking data collected days prior to the observations. Our optical observations in standard astronomical BVRI filters are done with either telescope, and with the telescope tracking the debris object at the object's angular rate. Observations in different filters are obtained sequentially. We have obtained 71 calibrated sequences of R-B-V-I-R magnitudes. A total of 66 of these sequences have 3 or more good measurements in all filters (not contaminated by star streaks or in Earth's shadow). Most of these sequences show brightness variations, but a small subset has observed brightness variations consistent with that expected from observational errors alone. The majority of these stable objects are redder than a solar color in both B-R and R-I. There is no dependence on color with brightness. For a smaller sample of objects we have observed with synchronized CCD cameras on the two telescopes. The CTIO 0.9-m observes in B, and MODEST in R. The CCD cameras are electronically linked together so that the start time and

  5. Angioid streaks in a case of Camurati–Engelmann disease

    Directory of Open Access Journals (Sweden)

    Betül Tugcu

    2017-01-01

    Full Text Available Camurati–Engelmann disease (CED is a rare autosomal dominant disease with various phenotypic expressions. The hallmark of the disease is bilateral symmetric diaphyseal hyperostosis of the long bones with progressive involvement of the metaphysis. Ocular manifestations occur rarely and mainly result from bony overgrowth of the orbit and optic canal stenosis. We report a case of CED showing angioid streaks (ASs in both fundi with no macular involvement and discuss the possible theories of the pathogenesis of AS in this disease.

  6. Camera Layout Design for the Upper Stage Thrust Cone

    Science.gov (United States)

    Wooten, Tevin; Fowler, Bart

    2010-01-01

    Engineers in the Integrated Design and Analysis Division (EV30) use a variety of different tools to aid in the design and analysis of the Ares I vehicle. One primary tool in use is Pro-Engineer. Pro-Engineer is a computer-aided design (CAD) software that allows designers to create computer generated structural models of vehicle structures. For the Upper State thrust cone, Pro-Engineer was used to assist in the design of a layout for two camera housings. These cameras observe the separation between the first and second stage of the Ares I vehicle. For the Ares I-X, one standard speed camera was used. The Ares I design calls for two separate housings, three cameras, and a lighting system. With previous design concepts and verification strategies in mind, a new layout for the two camera design concept was developed with members of the EV32 team. With the new design, Pro-Engineer was used to draw the layout to observe how the two camera housings fit with the thrust cone assembly. Future analysis of the camera housing design will verify the stability and clearance of the camera with other hardware present on the thrust cone.

  7. Global Calibration of Multiple Cameras Based on Sphere Targets

    Directory of Open Access Journals (Sweden)

    Junhua Sun

    2016-01-01

    Full Text Available Global calibration methods for multi-camera system are critical to the accuracy of vision measurement. Proposed in this paper is such a method based on several groups of sphere targets and a precision auxiliary camera. Each camera to be calibrated observes a group of spheres (at least three, while the auxiliary camera observes all the spheres. The global calibration can be achieved after each camera reconstructs the sphere centers in its field of view. In the process of reconstructing a sphere center, a parameter equation is used to describe the sphere projection model. Theoretical analysis and computer simulation are carried out to analyze the factors that affect the calibration accuracy. Simulation results show that the parameter equation can largely improve the reconstruction accuracy. In the experiments, a two-camera system calibrated by our method is used to measure a distance about 578 mm, and the root mean squared error is within 0.14 mm. Furthermore, the experiments indicate that the method has simple operation and good flexibility, especially for the onsite multiple cameras without common field of view.

  8. State of art in radiation tolerant camera

    Energy Technology Data Exchange (ETDEWEB)

    Choi; Young Soo; Kim, Seong Ho; Cho, Jae Wan; Kim, Chang Hoi; Seo, Young Chil

    2002-02-01

    Working in radiation environment such as nuclear power plant, RI facility, nuclear fuel fabrication facility, medical center has to be considered radiation exposure, and we can implement these job by remote observation and operation. However the camera used for general industry is weakened at radiation, so radiation-tolerant camera is needed for radiation environment. The application of radiation-tolerant camera system is nuclear industry, radio-active medical, aerospace, and so on. Specially nuclear industry, the demand is continuous in the inspection of nuclear boiler, exchange of pellet, inspection of nuclear waste. In the nuclear developed countries have been an effort to develop radiation-tolerant cameras. Now they have many kinds of radiation-tolerant cameras which can tolerate to 10{sup 6}-10{sup 8} rad total dose. In this report, we examine into the state-of-art about radiation-tolerant cameras, and analyze these technology. We want to grow up the concern of developing radiation-tolerant camera by this paper, and upgrade the level of domestic technology.

  9. Study and use of an infrared camera optimized for ground based observations in the 10 micron wavelength range

    International Nuclear Information System (INIS)

    Remy, Sophie

    1991-01-01

    Astronomical observations in the 10 micron atmospheric window provide very important information for many of astrophysical topics. But because of the very large terrestrial photon background at that wavelength, ground based observations have been impeded. On the other band, the ground based telescopes offer a greater angular resolution than the spatially based telescopes. The recent development of detector arrays for the mid infrared range made easier the development of infrared cameras with optimized detectors for astronomical observations from the ground. The CAMIRAS infrared camera, built by the 'Service d'Astrophysique' in Saclay is the instrument we have studied and we present its performances. Its sensitivity, given for an integration time of one minute on source and a signal to noise ratio of 3, is 0.15 Jy for punctual sources, and 20 mJy arcs"-"2 for extended sources. But we need to get rid of the enormous photon background so we have to find a better way of observation based on modulation techniques as 'chopping' or 'nodding'. Thus we show that a modulation about 1 Hz is satisfactory with our detectors arrays without perturbing the signal to noise ratio. As we have a good instrument and because we are able to get rid of the photon background, we can study astronomical objects. Results from a comet, dusty stellar disks, and an ultra-luminous galaxy are presented. (author) [fr

  10. Dual cameras acquisition and display system of retina-like sensor camera and rectangular sensor camera

    Science.gov (United States)

    Cao, Nan; Cao, Fengmei; Lin, Yabin; Bai, Tingzhu; Song, Shengyu

    2015-04-01

    For a new kind of retina-like senor camera and a traditional rectangular sensor camera, dual cameras acquisition and display system need to be built. We introduce the principle and the development of retina-like senor. Image coordinates transformation and interpolation based on sub-pixel interpolation need to be realized for our retina-like sensor's special pixels distribution. The hardware platform is composed of retina-like senor camera, rectangular sensor camera, image grabber and PC. Combined the MIL and OpenCV library, the software program is composed in VC++ on VS 2010. Experience results show that the system can realizes two cameras' acquisition and display.

  11. Electron streaking and dissociation in laser-assisted photoionization of molecular hydrogen

    International Nuclear Information System (INIS)

    Palacios, Alicia; González-Castrillo, Alberto; Martín, Fernando

    2014-01-01

    We report ab initio calculations on laser-assisted photoionization of the hydrogen molecule in the energy region where autoionization from doubly excited states is expected to occur. We use a UV-pump/IR-probe scheme in which an isolated attosecond UV pulse and a 750 nm IR pulse are combined. The IR pulse has a relatively low intensity (10 12 W cm −2 ), which allows us to perform a perturbative analysis of the calculated ionization probabilities differential in either electron or nuclear energy or both. We show that, for dissociative ionization, the electron energy distributions as a function of time delay exhibit unusual streaking patterns that are due to the presence of autoionizing states. These patterns significantly differ from the standard ones observed in direct single ionization of atoms and molecules. We also show that, by using such a pump–probe scheme, one can suppress autoionization from doubly excited states for time delays between 0 and 4 fs. (paper)

  12. Nuclear import of Maize fine streak virus proteins in Drosophila S2 cells

    Science.gov (United States)

    Maize fine streak virus (MFSV) is a member of the genus Nucleorhabdovirus, family Rhabdoviridae and is transmitted by the leafhopper Graminella nigrifons. The virus replicates in both its plant host and in its insect vector. Nucleorhabdoviruses replicate in the nucleus and assemble at the inner nu...

  13. Laser scanning camera inspects hazardous area

    International Nuclear Information System (INIS)

    Fryatt, A.; Miprode, C.

    1985-01-01

    Main operational characteristics of a new laser scanning camera are presented. The camera is intended primarily for low level high resolution viewing inside nuclear reactors. It uses a He-Ne laser beam raster; by detecting the reflected light by means of a phomultiplier, the subject under observation can be reconstructed in an electronic video store and reviewed on a conventional monitor screen

  14. Improving Photometric Calibration of Meteor Video Camera Systems

    Science.gov (United States)

    Ehlert, Steven; Kingery, Aaron; Suggs, Robert

    2017-01-01

    We present the results of new calibration tests performed by the NASA Meteoroid Environment Office (MEO) designed to help quantify and minimize systematic uncertainties in meteor photometry from video camera observations. These systematic uncertainties can be categorized by two main sources: an imperfect understanding of the linearity correction for the MEO's Watec 902H2 Ultimate video cameras and uncertainties in meteor magnitudes arising from transformations between the Watec camera's Sony EX-View HAD bandpass and the bandpasses used to determine reference star magnitudes. To address the first point, we have measured the linearity response of the MEO's standard meteor video cameras using two independent laboratory tests on eight cameras. Our empirically determined linearity correction is critical for performing accurate photometry at low camera intensity levels. With regards to the second point, we have calculated synthetic magnitudes in the EX bandpass for reference stars. These synthetic magnitudes enable direct calculations of the meteor's photometric flux within the camera bandpass without requiring any assumptions of its spectral energy distribution. Systematic uncertainties in the synthetic magnitudes of individual reference stars are estimated at approx. 0.20 mag, and are limited by the available spectral information in the reference catalogs. These two improvements allow for zero-points accurate to 0.05 - 0.10 mag in both filtered and unfiltered camera observations with no evidence for lingering systematics. These improvements are essential to accurately measuring photometric masses of individual meteors and source mass indexes.

  15. Avoiding acidic region streaking in two-dimensional gel electrophoresis: case study with two bacterial whole cell protein extracts.

    Science.gov (United States)

    Roy, Arnab; Varshney, Umesh; Pal, Debnath

    2014-09-01

    Acidic region streaking (ARS) is one of the lacunae in two-dimensional gel electrophoresis (2DE) of bacterial proteome. This streaking is primarily caused by nucleic acid (NuA) contamination and poses major problem in the downstream processes like image analysis and protein identification. Although cleanup and nuclease digestion are practiced as remedial options, these strategies may incur loss in protein recovery and perform incomplete removal of NuA. As a result, ARS has remained a common observation across publications, including the recent ones. In this work, we demonstrate how ultrasound wave can be used to shear NuA in plain ice-cooled water, facilitating the elimination of ARS in the 2DE gels without the need for any additional sample cleanup tasks. In combination with a suitable buffer recipe, IEF program and frequent paper-wick changing approach, we are able to reproducibly demonstrate the production of clean 2DE gels with improved protein recovery and negligible or no ARS. We illustrate our procedure using whole cell protein extracts from two diverse organisms, Escherichia coli and Mycobacterium smegmatis. Our designed protocols are straightforward and expected to provide good 2DE gels without ARS, with comparable times and significantly lower cost.

  16. The fly's eye camera system

    Science.gov (United States)

    Mészáros, L.; Pál, A.; Csépány, G.; Jaskó, A.; Vida, K.; Oláh, K.; Mezö, G.

    2014-12-01

    We introduce the Fly's Eye Camera System, an all-sky monitoring device intended to perform time domain astronomy. This camera system design will provide complementary data sets for other synoptic sky surveys such as LSST or Pan-STARRS. The effective field of view is obtained by 19 cameras arranged in a spherical mosaic form. These individual cameras of the device stand on a hexapod mount that is fully capable of achieving sidereal tracking for the subsequent exposures. This platform has many advantages. First of all it requires only one type of moving component and does not include unique parts. Hence this design not only eliminates problems implied by unique elements, but the redundancy of the hexapod allows smooth operations even if one or two of the legs are stuck. In addition, it can calibrate itself by observed stars independently from both the geographical location (including northen and southern hemisphere) and the polar alignment of the full mount. All mechanical elements and electronics are designed within the confines of our institute Konkoly Observatory. Currently, our instrument is in testing phase with an operating hexapod and reduced number of cameras.

  17. Video content analysis on body-worn cameras for retrospective investigation

    NARCIS (Netherlands)

    Bouma, H.; Baan, J.; Haar, F.B. ter; Eendebak, P.T.; Hollander, R.J.M. den; Burghouts, G.J.; Wijn, R.; Broek, S.P. van den; Rest, J.H.C. van

    2015-01-01

    In the security domain, cameras are important to assess critical situations. Apart from fixed surveillance cameras we observe an increasing number of sensors on mobile platforms, such as drones, vehicles and persons. Mobile cameras allow rapid and local deployment, enabling many novel applications

  18. System Configuration and Operation Plan of Hayabusa2 DCAM3-D Camera System for Scientific Observation During SCI Impact Experiment

    Science.gov (United States)

    Ogawa, Kazunori; Shirai, Kei; Sawada, Hirotaka; Arakawa, Masahiko; Honda, Rie; Wada, Koji; Ishibashi, Ko; Iijima, Yu-ichi; Sakatani, Naoya; Nakazawa, Satoru; Hayakawa, Hajime

    2017-07-01

    An artificial impact experiment is scheduled for 2018-2019 in which an impactor will collide with asteroid 162137 Ryugu (1999 JU3) during the asteroid rendezvous phase of the Hayabusa2 spacecraft. The small carry-on impactor (SCI) will shoot a 2-kg projectile at 2 km/s to create a crater 1-10 m in diameter with an expected subsequent ejecta curtain of a 100-m scale on an ideal sandy surface. A miniaturized deployable camera (DCAM3) unit will separate from the spacecraft at about 1 km from impact, and simultaneously conduct optical observations of the experiment. We designed and developed a camera system (DCAM3-D) in the DCAM3, specialized for scientific observations of impact phenomenon, in order to clarify the subsurface structure, construct theories of impact applicable in a microgravity environment, and identify the impact point on the asteroid. The DCAM3-D system consists of a miniaturized camera with a wide-angle and high-focusing performance, high-speed radio communication devices, and control units with large data storage on both the DCAM3 unit and the spacecraft. These components were successfully developed under severe constraints of size, mass and power, and the whole DCAM3-D system has passed all tests verifying functions, performance, and environmental tolerance. Results indicated sufficient potential to conduct the scientific observations during the SCI impact experiment. An operation plan was carefully considered along with the configuration and a time schedule of the impact experiment, and pre-programed into the control unit before the launch. In this paper, we describe details of the system design concept, specifications, and the operating plan of the DCAM3-D system, focusing on the feasibility of scientific observations.

  19. Streak-photographic investigation of shock wave emission after laser-induced plasma formation in water

    Science.gov (United States)

    Noack, Joachim; Vogel, Alfred

    1995-05-01

    The shock wave emission after dielectric breakdown in water was investigated to assess potential shock wave effects in plasma mediated tissue ablation and intraocular photodisruption. Of particular interest was the dependence of shock wave pressure as a function of distance from the plasma for different laser pulse energies. We have generated plasmas in water with a Nd:YAG laser system delivering pulses of 6 ns duration. The pulses, with energies between 0.4 and 36 mJ (approximately equals 180 times threshold), were focused into a cuvette containing distilled water. The shock wave was visualized with streak photography combined with a schlieren technique. An important advantage of this technique is that the shock position as a function of time can directly be obtained from a single streak and hence a single event. Other methods (e.g. flash photography or passage time measurements between fixed locations) in contrast rely on reproducible events. Using the shock wave speed obtained from the streak images, shock wave peak pressures were calculated providing detailed information on the propagation of the shock. The shock peak pressure as a function of distance r from the optical axis was found to decrease faster than 1/r2 in regions up to distances of 100-150 micrometers . For larger distances it was found to be roughly proportional to 1/r. The scaling law for maximum shock pressure p, at a given distance was found to be proportional to the square root of the laser pulse energy E for distances of 50-200 micrometers from the optical axis.

  20. Characterization of SWIR cameras by MRC measurements

    Science.gov (United States)

    Gerken, M.; Schlemmer, H.; Haan, Hubertus A.; Siemens, Christofer; Münzberg, M.

    2014-05-01

    Cameras for the SWIR wavelength range are becoming more and more important because of the better observation range for day-light operation under adverse weather conditions (haze, fog, rain). In order to choose the best suitable SWIR camera or to qualify a camera for a given application, characterization of the camera by means of the Minimum Resolvable Contrast MRC concept is favorable as the MRC comprises all relevant properties of the instrument. With the MRC known for a given camera device the achievable observation range can be calculated for every combination of target size, illumination level or weather conditions. MRC measurements in the SWIR wavelength band can be performed widely along the guidelines of the MRC measurements of a visual camera. Typically measurements are performed with a set of resolution targets (e.g. USAF 1951 target) manufactured with different contrast values from 50% down to less than 1%. For a given illumination level the achievable spatial resolution is then measured for each target. The resulting curve is showing the minimum contrast that is necessary to resolve the structure of a target as a function of spatial frequency. To perform MRC measurements for SWIR cameras at first the irradiation parameters have to be given in radiometric instead of photometric units which are limited in their use to the visible range. In order to do so, SWIR illumination levels for typical daylight and twilight conditions have to be defined. At second, a radiation source is necessary with appropriate emission in the SWIR range (e.g. incandescent lamp) and the irradiance has to be measured in W/m2 instead of Lux = Lumen/m2. At third, the contrast values of the targets have to be calibrated newly for the SWIR range because they typically differ from the values determined for the visual range. Measured MRC values of three cameras are compared to the specified performance data of the devices and the results of a multi-band in-house designed Vis-SWIR camera

  1. Prism-based single-camera system for stereo display

    Science.gov (United States)

    Zhao, Yue; Cui, Xiaoyu; Wang, Zhiguo; Chen, Hongsheng; Fan, Heyu; Wu, Teresa

    2016-06-01

    This paper combines the prism and single camera and puts forward a method of stereo imaging with low cost. First of all, according to the principle of geometrical optics, we can deduce the relationship between the prism single-camera system and dual-camera system, and according to the principle of binocular vision we can deduce the relationship between binoculars and dual camera. Thus we can establish the relationship between the prism single-camera system and binoculars and get the positional relation of prism, camera, and object with the best effect of stereo display. Finally, using the active shutter stereo glasses of NVIDIA Company, we can realize the three-dimensional (3-D) display of the object. The experimental results show that the proposed approach can make use of the prism single-camera system to simulate the various observation manners of eyes. The stereo imaging system, which is designed by the method proposed by this paper, can restore the 3-D shape of the object being photographed factually.

  2. Autonomous Multicamera Tracking on Embedded Smart Cameras

    Directory of Open Access Journals (Sweden)

    Bischof Horst

    2007-01-01

    Full Text Available There is currently a strong trend towards the deployment of advanced computer vision methods on embedded systems. This deployment is very challenging since embedded platforms often provide limited resources such as computing performance, memory, and power. In this paper we present a multicamera tracking method on distributed, embedded smart cameras. Smart cameras combine video sensing, processing, and communication on a single embedded device which is equipped with a multiprocessor computation and communication infrastructure. Our multicamera tracking approach focuses on a fully decentralized handover procedure between adjacent cameras. The basic idea is to initiate a single tracking instance in the multicamera system for each object of interest. The tracker follows the supervised object over the camera network, migrating to the camera which observes the object. Thus, no central coordination is required resulting in an autonomous and scalable tracking approach. We have fully implemented this novel multicamera tracking approach on our embedded smart cameras. Tracking is achieved by the well-known CamShift algorithm; the handover procedure is realized using a mobile agent system available on the smart camera network. Our approach has been successfully evaluated on tracking persons at our campus.

  3. Bilateral choroidal neovascularization response to unilateral intravitreal Ranibizumab injection in a patient with angioid streaks

    Directory of Open Access Journals (Sweden)

    Otacílio de Oliveira Maia Júnior

    2013-08-01

    Full Text Available Report of a 48 year-old male with bilateral decrease in vision due to choroidal neovascularization secondary to angioid streaks. Best corrected visual acuity was 20/80 in the right eye and counting fingers at 2 meters on the left eye. Patient underwent intravitreal injection of Ranibizumab (Lucentis in the eye with worse visual acuity. Fifteen days after treatment patient reported better visual acuity on the fellow eye, which was measured to be 20/25. Treatment result was evaluated with visual acuity and optical coherence tomography. The effect of ranibizumab was observed in the treated eye, but the fellow eye had complete resolution of the choroidal neovascularization complex. This result may be a response to systemic absorption of the medication.

  4. The status of MUSIC: the multiwavelength sub-millimeter inductance camera

    Science.gov (United States)

    Sayers, Jack; Bockstiegel, Clint; Brugger, Spencer; Czakon, Nicole G.; Day, Peter K.; Downes, Thomas P.; Duan, Ran P.; Gao, Jiansong; Gill, Amandeep K.; Glenn, Jason; Golwala, Sunil R.; Hollister, Matthew I.; Lam, Albert; LeDuc, Henry G.; Maloney, Philip R.; Mazin, Benjamin A.; McHugh, Sean G.; Miller, David A.; Mroczkowski, Anthony K.; Noroozian, Omid; Nguyen, Hien Trong; Schlaerth, James A.; Siegel, Seth R.; Vayonakis, Anastasios; Wilson, Philip R.; Zmuidzinas, Jonas

    2014-08-01

    The Multiwavelength Sub/millimeter Inductance Camera (MUSIC) is a four-band photometric imaging camera operating from the Caltech Submillimeter Observatory (CSO). MUSIC is designed to utilize 2304 microwave kinetic inductance detectors (MKIDs), with 576 MKIDs for each observing band centered on 150, 230, 290, and 350 GHz. MUSIC's field of view (FOV) is 14' square, and the point-spread functions (PSFs) in the four observing bands have 45'', 31'', 25'', and 22'' full-widths at half maximum (FWHM). The camera was installed in April 2012 with 25% of its nominal detector count in each band, and has subsequently completed three short sets of engineering observations and one longer duration set of early science observations. Recent results from on-sky characterization of the instrument during these observing runs are presented, including achieved map- based sensitivities from deep integrations, along with results from lab-based measurements made during the same period. In addition, recent upgrades to MUSIC, which are expected to significantly improve the sensitivity of the camera, are described.

  5. The Use of Camera Traps in Wildlife

    Directory of Open Access Journals (Sweden)

    Yasin Uçarlı

    2013-11-01

    Full Text Available Camera traps are increasingly used in the abundance and density estimates of wildlife species. Camera traps are very good alternative for direct observation in case, particularly, steep terrain, dense vegetation covered areas or nocturnal species. The main reason for the use of camera traps is eliminated that the economic, personnel and time loss in a continuous manner at the same time in different points. Camera traps, motion and heat sensitive, can take a photo or video according to the models. Crossover points and feeding or mating areas of the focal species are addressed as a priority camera trap set locations. The population size can be finding out by the images combined with Capture-Recapture methods. The population density came out the population size divided to effective sampling area size. Mating and breeding season, habitat choice, group structures and survival rates of the focal species can be achieved from the images. Camera traps are very useful to obtain the necessary data about the particularly mysterious species with economically in planning and conservation efforts.

  6. Continuous monitoring of Hawaiian volcanoes with thermal cameras

    Science.gov (United States)

    Patrick, Matthew R.; Orr, Tim R.; Antolik, Loren; Lee, Robert Lopaka; Kamibayashi, Kevan P.

    2014-01-01

    Continuously operating thermal cameras are becoming more common around the world for volcano monitoring, and offer distinct advantages over conventional visual webcams for observing volcanic activity. Thermal cameras can sometimes “see” through volcanic fume that obscures views to visual webcams and the naked eye, and often provide a much clearer view of the extent of high temperature areas and activity levels. We describe a thermal camera network recently installed by the Hawaiian Volcano Observatory to monitor Kīlauea’s summit and east rift zone eruptions (at Halema‘uma‘u and Pu‘u ‘Ō‘ō craters, respectively) and to keep watch on Mauna Loa’s summit caldera. The cameras are long-wave, temperature-calibrated models protected in custom enclosures, and often positioned on crater rims close to active vents. Images are transmitted back to the observatory in real-time, and numerous Matlab scripts manage the data and provide automated analyses and alarms. The cameras have greatly improved HVO’s observations of surface eruptive activity, which includes highly dynamic lava lake activity at Halema‘uma‘u, major disruptions to Pu‘u ‘Ō‘ō crater and several fissure eruptions.

  7. Improvements in picosecond chronography

    International Nuclear Information System (INIS)

    Arthurs, E.G.; Bradley, D.J.; Liddy, Brian; O'Neill, Fergus; Roddie, A.G.; Sibbett, Wilson; Sleat, W.E.

    The durations of laser pulses as short as 1 picosecond have been measured with an electro-optical streak camera. The time resolution limit of the camera system has been directly and unambiguously demonstrated employing a flashlamp pumped mode-locked dye laser to reliably generate tunable-frequency pulses of duration between 1 and 2 psec. An argon laser pumped C.W. mode-locked dye laser has been developed using the streak camera as a diagnostic tool, to produce continuous streams of picosecond pulses. With the high light gain of the camera system, pulses of peak powers < 1 watt can be studied with picosecond time resolution. The build-up of picosecond pulses from the initial photon noise of the mode-locked laser has also been directly recorded for the first time

  8. Intellectual streaking: The value of teachers exposing minds (and hearts).

    Science.gov (United States)

    Bearman, Margaret; Molloy, Elizabeth

    2017-12-01

    As teachers we often ask learners to be vulnerable and yet present ourselves as high status, knowledgeable experts, often with pre-prepared scripts. This paper investigates the metaphoric notion of "intellectual streaking" - the nimble exposure of a teacher's thought processes, dilemmas, or failures - as a way of modeling both reflection-in-action and resilience. While there is a tension between credibility and vulnerability, both of which are necessary for trust, we argue that taking a few risks and revealing deficits in knowledge or performance can be illuminating and valuable for all parties.

  9. Underwater television camera for monitoring inner side of pressure vessel

    International Nuclear Information System (INIS)

    Takayama, Kazuhiko.

    1997-01-01

    An underwater television support device equipped with a rotatable and vertically movable underwater television camera and an underwater television camera controlling device for monitoring images of the inside of the reactor core photographed by the underwater television camera to control the position of the underwater television camera and the underwater light are disposed on an upper lattice plate of a reactor pressure vessel. Both of them are electrically connected with each other by way of a cable to rapidly observe the inside of the reactor core by the underwater television camera. The reproducibility is extremely satisfactory by efficiently concentrating the position of the camera and image information upon inspection and observation. As a result, the steps for periodical inspection can be reduced to shorten the days for the periodical inspection. Since there is no requirement to withdraw fuel assemblies over a wide reactor core region, and the device can be used with the fuel assemblies being left as they are in the reactor, it is suitable for inspection of detectors for nuclear instrumentation. (N.H.)

  10. Development of underwater camera using high-definition camera

    International Nuclear Information System (INIS)

    Tsuji, Kenji; Watanabe, Masato; Takashima, Masanobu; Kawamura, Shingo; Tanaka, Hiroyuki

    2012-01-01

    In order to reduce the time for core verification or visual inspection of BWR fuels, the underwater camera using a High-Definition camera has been developed. As a result of this development, the underwater camera has 2 lights and 370 x 400 x 328mm dimensions and 20.5kg weight. Using the camera, 6 or so spent-fuel IDs are identified at 1 or 1.5m distance at a time, and 0.3mmφ pin-hole is recognized at 1.5m distance and 20 times zoom-up. Noises caused by radiation less than 15 Gy/h are not affected the images. (author)

  11. Nonlinear longitudinal dynamics studies at the ALS

    International Nuclear Information System (INIS)

    Byrd, J.M.; Cheng, W.-H.; De Santis, S.; Li, D.; Stupakov, G.; Zimmermann, F.

    1999-01-01

    We present a summary of results for a variety of studies of nonlinear longitudinal dynamics in the Advanced Light Source, an electron storage ring. These include observation of decoherence at injection, decay of an injected beam, forced synchrotron oscillations and diffusion from one bunch to the next. All of the measurements were made using a dual-scan streak camera which allowed the real-time observation of the longitudinal distribution of the electron beam

  12. Sub-Camera Calibration of a Penta-Camera

    Science.gov (United States)

    Jacobsen, K.; Gerke, M.

    2016-03-01

    Penta cameras consisting of a nadir and four inclined cameras are becoming more and more popular, having the advantage of imaging also facades in built up areas from four directions. Such system cameras require a boresight calibration of the geometric relation of the cameras to each other, but also a calibration of the sub-cameras. Based on data sets of the ISPRS/EuroSDR benchmark for multi platform photogrammetry the inner orientation of the used IGI Penta DigiCAM has been analyzed. The required image coordinates of the blocks Dortmund and Zeche Zollern have been determined by Pix4Dmapper and have been independently adjusted and analyzed by program system BLUH. With 4.1 million image points in 314 images respectively 3.9 million image points in 248 images a dense matching was provided by Pix4Dmapper. With up to 19 respectively 29 images per object point the images are well connected, nevertheless the high number of images per object point are concentrated to the block centres while the inclined images outside the block centre are satisfying but not very strongly connected. This leads to very high values for the Student test (T-test) of the finally used additional parameters or in other words, additional parameters are highly significant. The estimated radial symmetric distortion of the nadir sub-camera corresponds to the laboratory calibration of IGI, but there are still radial symmetric distortions also for the inclined cameras with a size exceeding 5μm even if mentioned as negligible based on the laboratory calibration. Radial and tangential effects of the image corners are limited but still available. Remarkable angular affine systematic image errors can be seen especially in the block Zeche Zollern. Such deformations are unusual for digital matrix cameras, but it can be caused by the correlation between inner and exterior orientation if only parallel flight lines are used. With exception of the angular affinity the systematic image errors for corresponding

  13. Relative camera localisation in non-overlapping camera networks using multiple trajectories

    NARCIS (Netherlands)

    John, V.; Englebienne, G.; Kröse, B.J.A.

    2012-01-01

    In this article we present an automatic camera calibration algorithm using multiple trajectories in a multiple camera network with non-overlapping field-of-views (FOV). Visible trajectories within a camera FOV are assumed to be measured with respect to the camera local co-ordinate system.

  14. Real-time vehicle matching for multi-camera tunnel surveillance

    Science.gov (United States)

    Jelača, Vedran; Niño Castañeda, Jorge Oswaldo; Frías-Velázquez, Andrés; Pižurica, Aleksandra; Philips, Wilfried

    2011-03-01

    Tracking multiple vehicles with multiple cameras is a challenging problem of great importance in tunnel surveillance. One of the main challenges is accurate vehicle matching across the cameras with non-overlapping fields of view. Since systems dedicated to this task can contain hundreds of cameras which observe dozens of vehicles each, for a real-time performance computational efficiency is essential. In this paper, we propose a low complexity, yet highly accurate method for vehicle matching using vehicle signatures composed of Radon transform like projection profiles of the vehicle image. The proposed signatures can be calculated by a simple scan-line algorithm, by the camera software itself and transmitted to the central server or to the other cameras in a smart camera environment. The amount of data is drastically reduced compared to the whole image, which relaxes the data link capacity requirements. Experiments on real vehicle images, extracted from video sequences recorded in a tunnel by two distant security cameras, validate our approach.

  15. Attosecond delay in the molecular photoionization of asymmetric molecules.

    Science.gov (United States)

    Chacón, Alexis; Ruiz, Camilo

    2018-02-19

    We report theoretical calculations of the delay in photoemission from CO with particular emphasis on the role of the ultrafast electronic bound dynamics. We study the delays in photoionization in the HOMO and HOMO-1 orbitals of the CO molecule by looking into the stereo Wigner time delay technique. That compares the delay in photoemission from electrons emitted to the left and right to extract structural and dynamical information of the ionization process. For this we apply two techniques: The attosecond streak camera and the time of flight technique. Although they should provide the same results we have found large discrepancies of up to 36 in the case of HOMO, while for the HOMO-1 we obtain the same results with the two techniques. We have found that the large time delays observed in the HOMO orbital with the streaking technique are a consequence of the resonant transition triggered by the streaking field. This resonant transition produces a bound electron wavepacket that modifies the measurements of delay in photoionization. As a result of this observation, our technique allows us to reconstruct the bound wavepacket dynamics induced by the streaking field. By measuring the expected value of the electron momentum along the polarization direction after the streaking field has finished, we can recover the relative phase between the complex amplitudes of the HOMO and LUMO orbitals. These theoretical calculations pave the way for the measurement of ultrafast bound-bound electron transitionsand its crucial role for the delay in photoemission observation.

  16. Visual Positioning Indoors: Human Eyes vs. Smartphone Cameras.

    Science.gov (United States)

    Wu, Dewen; Chen, Ruizhi; Chen, Liang

    2017-11-16

    Artificial Intelligence (AI) technologies and their related applications are now developing at a rapid pace. Indoor positioning will be one of the core technologies that enable AI applications because people spend 80% of their time indoors. Humans can locate themselves related to a visually well-defined object, e.g., a door, based on their visual observations. Can a smartphone camera do a similar job when it points to an object? In this paper, a visual positioning solution was developed based on a single image captured from a smartphone camera pointing to a well-defined object. The smartphone camera simulates the process of human eyes for the purpose of relatively locating themselves against a well-defined object. Extensive experiments were conducted with five types of smartphones on three different indoor settings, including a meeting room, a library, and a reading room. Experimental results shown that the average positioning accuracy of the solution based on five smartphone cameras is 30.6 cm, while that for the human-observed solution with 300 samples from 10 different people is 73.1 cm.

  17. Wheat streak mosaic virus coat protein is a host-specific long-distance transport determinant in oat

    Science.gov (United States)

    Viral determinants involved in systemic infection of hosts by monocot-infecting plant viruses are poorly understood. Wheat streak mosaic virus (WSMV, genus Tritimovirus, family Potyviridae) exclusively infects monocotyledonous crops such as wheat, oat, barley, maize, triticale, and rye. Previously, ...

  18. Development and setting of a time-lapse video camera system for the Antarctic lake observation

    Directory of Open Access Journals (Sweden)

    Sakae Kudoh

    2010-11-01

    Full Text Available A submersible video camera system, which aimed to record the growth image of aquatic vegetation in Antarctic lakes for one year, was manufactured. The system consisted of a video camera, a programmable controller unit, a lens-cleaning wiper with a submersible motor, LED lights, and a lithium ion battery unit. Changes of video camera (High Vision System and modification of the lens-cleaning wiper allowed higher sensitivity and clearer recording images compared to the previous submersible video without increasing the power consumption. This system was set on the lake floor in Lake Naga Ike (a tentative name in Skarvsnes in Soya Coast, during the summer activity of the 51th Japanese Antarctic Research Expedition. Interval record of underwater visual image for one year have been started by our diving operation.

  19. Epistatic determinism of durum wheat resistance to the wheat spindle streak mosaic virus.

    Science.gov (United States)

    Holtz, Yan; Bonnefoy, Michel; Viader, Véronique; Ardisson, Morgane; Rode, Nicolas O; Poux, Gérard; Roumet, Pierre; Marie-Jeanne, Véronique; Ranwez, Vincent; Santoni, Sylvain; Gouache, David; David, Jacques L

    2017-07-01

    The resistance of durum wheat to the Wheat spindle streak mosaic virus (WSSMV) is controlled by two main QTLs on chromosomes 7A and 7B, with a huge epistatic effect. Wheat spindle streak mosaic virus (WSSMV) is a major disease of durum wheat in Europe and North America. Breeding WSSMV-resistant cultivars is currently the only way to control the virus since no treatment is available. This paper reports studies of the inheritance of WSSMV resistance using two related durum wheat populations obtained by crossing two elite cultivars with a WSSMV-resistant emmer cultivar. In 2012 and 2015, 354 recombinant inbred lines (RIL) were phenotyped using visual notations, ELISA and qPCR and genotyped using locus targeted capture and sequencing. This allowed us to build a consensus genetic map of 8568 markers and identify three chromosomal regions involved in WSSMV resistance. Two major regions (located on chromosomes 7A and 7B) jointly explain, on the basis of epistatic interactions, up to 43% of the phenotypic variation. Flanking sequences of our genetic markers are provided to facilitate future marker-assisted selection of WSSMV-resistant cultivars.

  20. Evaluation of banana hybrids for tolerance to black leaf streak (Mycosphaerella fijiensis Morelet) in Puerto Rico

    Science.gov (United States)

    In Puerto Rico, bananas (including plantains) are important agricultural commodities; their combined production totaled 133,500 tons in 2008. Black leaf streak (BLS) and Sigatoka leaf spot diseases, caused by Mycosphaerella fijiensis and M. musicola, respectively, are responsible for significant los...

  1. Using a slit lamp-mounted digital high-speed camera for dynamic observation of phakic lenses during eye movements: a pilot study

    Directory of Open Access Journals (Sweden)

    Leitritz MA

    2014-07-01

    Full Text Available Martin Alexander Leitritz, Focke Ziemssen, Karl Ulrich Bartz-Schmidt, Bogomil Voykov Centre for Ophthalmology, University Eye Hospital, Eberhard Karls University of Tübingen, Tübingen, Germany Purpose: To evaluate a digital high-speed camera combined with digital morphometry software for dynamic measurements of phakic intraocular lens movements to observe kinetic influences, particularly in fast direction changes and at lateral end points. Materials and methods: A high-speed camera taking 300 frames per second observed movements of eight iris-claw intraocular lenses and two angle-supported intraocular lenses. Standardized saccades were performed by the patients to trigger mass inertia with lens position changes. Freeze images with maximum deviation were used for digital software-based morphometry analysis with ImageJ.Results: Two eyes from each of five patients (median age 32 years, range 28–45 years without findings other than refractive errors were included. The high-speed images showed sufficient usability for further morphometric processing. In the primary eye position, the median decentrations downward and in a lateral direction were -0.32 mm (range -0.69 to 0.024 and 0.175 mm (range -0.37 to 0.45, respectively. Despite the small sample size of asymptomatic patients, we found a considerable amount of lens dislocation. The median distance amplitude during eye movements was 0.158 mm (range 0.02–0.84. There was a slight positive corrlation (r=0.39, P<0.001 between the grade of deviation in the primary position and the distance increase triggered by movements.Conclusion: With the use of a slit lamp-mounted high-speed camera system and morphometry software, observation and objective measurements of iris-claw intraocular lenses and angle-supported intraocular lenses movements seem to be possible. Slight decentration in the primary position might be an indicator of increased lens mobility during kinetic stress during eye movements

  2. Thermal Analysis of MIRIS Space Observation Camera for Verification of Passive Cooling

    Directory of Open Access Journals (Sweden)

    Duk-Hang Lee

    2012-09-01

    Full Text Available We conducted thermal analyses and cooling tests of the space observation camera (SOC of the multi-purpose infrared imaging system (MIRIS to verify passive cooling. The thermal analyses were conducted with NX 7.0 TMG for two cases of attitude of the MIRIS: for the worst hot case and normal case. Through the thermal analyses of the flight model, it was found that even in the worst case the telescope could be cooled to less than 206°K. This is similar to the results of the passive cooling test (~200.2°K. For the normal attitude case of the analysis, on the other hand, the SOC telescope was cooled to about 160°K in 10 days. Based on the results of these analyses and the test, it was determined that the telescope of the MIRIS SOC could be successfully cooled to below 200°K with passive cooling. The SOC is, therefore, expected to have optimal performance under cooled conditions in orbit.

  3. Characterization of beam dynamics in the APS injector rings using time-resolved imaging techniques

    International Nuclear Information System (INIS)

    Yang, B.X.; Lumpkin, A.H.; Borland, M.

    1997-01-01

    Images taken with streak cameras and gated intensified cameras with both time (longitudinal) and spatial (transverse) resolution reveal a wealth of information about circular accelerators. The authors illustrate a novel technique by a sequence of dual-sweep streak camera images taken at a high dispersion location in the booster synchrotron, where the horizontal coordinate is strongly correlated with the particle energy and the open-quotes top-viewclose quotes of the beam gives a good approximation to the particle density distribution in the longitudinal phase space. A sequence of top-view images taken fight after injection clearly shows the beam dynamics in the phase space. We report another example from the positron accumulator ring for the characterization of its beam compression bunching with the 12th harmonic rf

  4. Invariant Observer-Based State Estimation for Micro-Aerial Vehicles in GPS-Denied Indoor Environments Using an RGB-D Camera and MEMS Inertial Sensors

    Directory of Open Access Journals (Sweden)

    Dachuan Li

    2015-04-01

    Full Text Available This paper presents a non-linear state observer-based integrated navigation scheme for estimating the attitude, position and velocity of micro aerial vehicles (MAV operating in GPS-denied indoor environments, using the measurements from low-cost MEMS (micro electro-mechanical systems inertial sensors and an RGB-D camera. A robust RGB-D visual odometry (VO approach was developed to estimate the MAV’s relative motion by extracting and matching features captured by the RGB-D camera from the environment. The state observer of the RGB-D visual-aided inertial navigation was then designed based on the invariant observer theory for systems possessing symmetries. The motion estimates from the RGB-D VO were fused with inertial and magnetic measurements from the onboard MEMS sensors via the state observer, providing the MAV with accurate estimates of its full six degree-of-freedom states. Implementations on a quadrotor MAV and indoor flight test results demonstrate that the resulting state observer is effective in estimating the MAV’s states without relying on external navigation aids such as GPS. The properties of computational efficiency and simplicity in gain tuning make the proposed invariant observer-based navigation scheme appealing for actual MAV applications in indoor environments.

  5. Laser fusion diagnostics

    International Nuclear Information System (INIS)

    Coleman, L.W.

    1978-01-01

    The current status of the capability of laser fusion diagnostics is reviewed. Optical and infrared streak cameras provide one time resolution measurement capability of less than 10 ps, while x-ray streak cameras provide 15 ps time resolution in the range of about 1--30 keV presently. Time integrated spatial resolutions of 1 μm are provided with a variety of optical techniques. Ultraviolet holographic interferometry has measured electron densities above 10 21 cm -3 with 1 μm spatial resolution and 15 ps temporal resolution. X-ray microscopes provide 3 μm time integrated resolution and the x-ray streak pinhole camera has 6 μm spatial resolution. Development of the framing camera has thus far provided 50 μm spatial resolution with 125 ps frame duration and the third order reconstruction of zone plate images has provided 3 μm resolutions for alpha particles. Time integrated measurements of x-rays span the range shown. Finally, the new Shiva neutron spectrometer increases the energy resolution capability of that technique to 25 keV for 14-MeV neutrons. These combined capabilities provide a unique set of diagnostics for the detailed measurement of the interaction of laser light with targets and a subsequent performance of those targets

  6. Bunch length measurements in the SLC damping ring

    International Nuclear Information System (INIS)

    Decker, F.J.; Limberg, T.; Minty, M.; Ross, M.

    1993-05-01

    The synchrotron light of the SLC damping ring was used to measure the bunch length with a streak camera at different times in the damping cycle. There are bunch length oscillations after injection, different equilibrium length during the cycle due to rf manipulations to avoid microwave instability oscillations, and just before extraction there is a longitudinal phase space rotation (bunch muncher) to shorten the bunch length. Measurements under these different conditions are presented and compared with BPM pulse height signals. Calibration and adjustment issues and the connection of the streak camera to the SLC control system are also discussed

  7. Observation of Possible Lava Tube Skylights by SELENE cameras

    Science.gov (United States)

    Haruyama, Junichi; Hiesinger, Harald; van der Bogert, Carolyn

    We have discovered three deep hole-structures on the Moon in the Terrain Camera and Multi-band Imager on the SELENE. These holes are large depth to diameter ratios: Marius Hills Hole (MHH) is 65 m in diameter and 88-90 m in depth, Mare Tranquillitatis Hole (MTH) is 120 x 110 m in diameter and 180 m in depth, and Mare Ingenii Hole (MIH) is 140 x 110 m in diameter and deeper than 90 m. No volcanic material from the holes nor dike-relating pit craters is seen around the holes. They are possible lava tube skylights. These holes and possibly connected tubes have a lot of scientific interests and high potentialities as lunar bases.

  8. Mobile phone camera benchmarking: combination of camera speed and image quality

    Science.gov (United States)

    Peltoketo, Veli-Tapani

    2014-01-01

    When a mobile phone camera is tested and benchmarked, the significance of quality metrics is widely acknowledged. There are also existing methods to evaluate the camera speed. For example, ISO 15781 defines several measurements to evaluate various camera system delays. However, the speed or rapidity metrics of the mobile phone's camera system have not been used with the quality metrics even if the camera speed has become more and more important camera performance feature. There are several tasks in this work. Firstly, the most important image quality metrics are collected from the standards and papers. Secondly, the speed related metrics of a mobile phone's camera system are collected from the standards and papers and also novel speed metrics are identified. Thirdly, combinations of the quality and speed metrics are validated using mobile phones in the market. The measurements are done towards application programming interface of different operating system. Finally, the results are evaluated and conclusions are made. The result of this work gives detailed benchmarking results of mobile phone camera systems in the market. The paper defines also a proposal of combined benchmarking metrics, which includes both quality and speed parameters.

  9. Construction of Double Right-Border Binary Vector Carrying Non-Host Gene Rxol Resistant to Bacterial Leaf Streak of Rice

    Institute of Scientific and Technical Information of China (English)

    Xu Mei-rong; XIA Zhi-hui; ZHAI Wen-xue; XU Jian-long; ZHOU Yong-li; LI Zhi-kang

    2008-01-01

    Rxol cloned from maize is a non-host gene resistant to bacterial leaf streak of rice. pCAMBIA1305-1 with Rxol was digested with Sca Ⅰ and NgoM Ⅳ and the double right-border binary vector pMNDRBBin6 was digested with Hpa Ⅰ and Xma Ⅰ.pMNDRBBin6 carrying the gene Rxol was acquired by ligation of blunt-end and cohesive end. The results of PCR, restriction enzyme analysis and sequencing indicated that the Rxol gene had been cloned into pMNDRBBin6. This double right-border binary vector,named as pMNDRBBin6-Rxol, will play a role in breeding marker-free plants resistant to bacterial leaf streak of rice by genetic transformation.

  10. Statistical iterative reconstruction for streak artefact reduction when using multidetector CT to image the dento-alveolar structures.

    Science.gov (United States)

    Dong, J; Hayakawa, Y; Kober, C

    2014-01-01

    When metallic prosthetic appliances and dental fillings exist in the oral cavity, the appearance of metal-induced streak artefacts is not avoidable in CT images. The aim of this study was to develop a method for artefact reduction using the statistical reconstruction on multidetector row CT images. Adjacent CT images often depict similar anatomical structures. Therefore, reconstructed images with weak artefacts were attempted using projection data of an artefact-free image in a neighbouring thin slice. Images with moderate and strong artefacts were continuously processed in sequence by successive iterative restoration where the projection data was generated from the adjacent reconstructed slice. First, the basic maximum likelihood-expectation maximization algorithm was applied. Next, the ordered subset-expectation maximization algorithm was examined. Alternatively, a small region of interest setting was designated. Finally, the general purpose graphic processing unit machine was applied in both situations. The algorithms reduced the metal-induced streak artefacts on multidetector row CT images when the sequential processing method was applied. The ordered subset-expectation maximization and small region of interest reduced the processing duration without apparent detriments. A general-purpose graphic processing unit realized the high performance. A statistical reconstruction method was applied for the streak artefact reduction. The alternative algorithms applied were effective. Both software and hardware tools, such as ordered subset-expectation maximization, small region of interest and general-purpose graphic processing unit achieved fast artefact correction.

  11. Beam diagnostics on ARGUS

    International Nuclear Information System (INIS)

    MacQuigg, D.R.; Speck, D.R.

    1976-01-01

    Performance of laser fusion targets depends critically on the characteristics of the incident beam. The spatial distribution and temporal behavior of the light incident on the target varies significantly with power, with choice of beam spatial profile and with location of spatial filters. On each ARGUS shot we photograph planes in the incident beams which are equivalent to the target plane. Array cameras record the time integrated energy distributions and streak cameras record the temporal behavior. Computer reduction of the photographic data provides detailed spatial energy distributions, and instantaneous power on target vs. time. Target performance correlates with the observed beam characteristics

  12. Engineering task plan for flammable gas atmosphere mobile color video camera systems

    International Nuclear Information System (INIS)

    Kohlman, E.H.

    1995-01-01

    This Engineering Task Plan (ETP) describes the design, fabrication, assembly, and testing of the mobile video camera systems. The color video camera systems will be used to observe and record the activities within the vapor space of a tank on a limited exposure basis. The units will be fully mobile and designed for operation in the single-shell flammable gas producing tanks. The objective of this tank is to provide two mobile camera systems for use in flammable gas producing single-shell tanks (SSTs) for the Flammable Gas Tank Safety Program. The camera systems will provide observation, video recording, and monitoring of the activities that occur in the vapor space of applied tanks. The camera systems will be designed to be totally mobile, capable of deployment up to 6.1 meters into a 4 inch (minimum) riser

  13. Comparative evaluation of consumer grade cameras and mobile phone cameras for close range photogrammetry

    Science.gov (United States)

    Chikatsu, Hirofumi; Takahashi, Yoji

    2009-08-01

    The authors have been concentrating on developing convenient 3D measurement methods using consumer grade digital cameras, and it was concluded that consumer grade digital cameras are expected to become a useful photogrammetric device for the various close range application fields. On the other hand, mobile phone cameras which have 10 mega pixels were appeared on the market in Japan. In these circumstances, we are faced with alternative epoch-making problem whether mobile phone cameras are able to take the place of consumer grade digital cameras in close range photogrammetric applications. In order to evaluate potentials of mobile phone cameras in close range photogrammetry, comparative evaluation between mobile phone cameras and consumer grade digital cameras are investigated in this paper with respect to lens distortion, reliability, stability and robustness. The calibration tests for 16 mobile phone cameras and 50 consumer grade digital cameras were conducted indoors using test target. Furthermore, practability of mobile phone camera for close range photogrammetry was evaluated outdoors. This paper presents that mobile phone cameras have ability to take the place of consumer grade digital cameras, and develop the market in digital photogrammetric fields.

  14. Dust-gas interaction deduced from Halley multicolour camera observations

    International Nuclear Information System (INIS)

    Huebner, W.F.; Delamere, W.A.; Keller, H.U.; Reitsema, H.J.; Schmidt, H.U.; Whipple, F.L.; Wilhelm, K.

    1986-01-01

    The dust and gas productions of Comet Halley were measured by the dust counter and the mass spectrometers on the Giotto spacecraft. These instruments give only little information about the spatial asymmetry of the activity. The asymmetry in the dust production is clearly evident from the dust jets seen in the Halley Multicolour Camera images. Since the dust is entrained by the gas, production must be similarly asymmetric. The intensity profiles along and across several dust jets are related to their source regions on the nucleus. Properties of the dust jets are investigated. A few compact, but highly active source regions on the nucleus produce most of the visible dust and can account for most of the gas produced by the comet. 2 refs

  15. Spectral analysis of amazon canopy phenology during the dry season using a tower hyperspectral camera and modis observations

    Science.gov (United States)

    de Moura, Yhasmin Mendes; Galvão, Lênio Soares; Hilker, Thomas; Wu, Jin; Saleska, Scott; do Amaral, Cibele Hummel; Nelson, Bruce Walker; Lopes, Aline Pontes; Wiedeman, Kenia K.; Prohaska, Neill; de Oliveira, Raimundo Cosme; Machado, Carolyne Bueno; Aragão, Luiz E. O. C.

    2017-09-01

    The association between spectral reflectance and canopy processes remains challenging for quantifying large-scale canopy phenological cycles in tropical forests. In this study, we used a tower-mounted hyperspectral camera in an eastern Amazon forest to assess how canopy spectral signals of three species are linked with phenological processes in the 2012 dry season. We explored different approaches to disentangle the spectral components of canopy phenology processes and analyze their variations over time using 17 images acquired by the camera. The methods included linear spectral mixture analysis (SMA); principal component analysis (PCA); continuum removal (CR); and first-order derivative analysis. In addition, three vegetation indices potentially sensitive to leaf flushing, leaf loss and leaf area index (LAI) were calculated: the Enhanced Vegetation Index (EVI), Normalized Difference Vegetation Index (NDVI) and the entitled Green-Red Normalized Difference (GRND) index. We inspected also the consistency of the camera observations using Moderate Resolution Imaging Spectroradiometer (MODIS) and available phenological data on new leaf production and LAI of young, mature and old leaves simulated by a leaf demography-ontogeny model. The results showed a diversity of phenological responses during the 2012 dry season with related changes in canopy structure and greenness values. Because of the differences in timing and intensity of leaf flushing and leaf shedding, Erisma uncinatum, Manilkara huberi and Chamaecrista xinguensis presented different green vegetation (GV) and non-photosynthetic vegetation (NPV) SMA fractions; distinct PCA scores; changes in depth, width and area of the 681-nm chlorophyll absorption band; and variations over time in the EVI, GRND and NDVI. At the end of dry season, GV increased for Erisma uncinatum, while NPV increased for Chamaecrista xinguensis. For Manilkara huberi, the NPV first increased in the beginning of August and then decreased toward

  16. Gamma camera

    International Nuclear Information System (INIS)

    Tschunt, E.; Platz, W.; Baer, U.; Heinz, L.

    1978-01-01

    A gamma camera has a plurality of exchangeable collimators, one of which is mounted in the ray inlet opening of the camera, while the others are placed on separate supports. The supports are swingably mounted upon a column one above the other through about 90 0 to a collimator exchange position. Each of the separate supports is swingable to a vertically aligned position, with limiting of the swinging movement and positioning of the support at the desired exchange position. The collimators are carried on the supports by means of a series of vertically disposed coil springs. Projections on the camera are movable from above into grooves of the collimator at the exchange position, whereupon the collimator is turned so that it is securely prevented from falling out of the camera head

  17. LAMOST CCD camera-control system based on RTS2

    Science.gov (United States)

    Tian, Yuan; Wang, Zheng; Li, Jian; Cao, Zi-Huang; Dai, Wei; Wei, Shou-Lin; Zhao, Yong-Heng

    2018-05-01

    The Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST) is the largest existing spectroscopic survey telescope, having 32 scientific charge-coupled-device (CCD) cameras for acquiring spectra. Stability and automation of the camera-control software are essential, but cannot be provided by the existing system. The Remote Telescope System 2nd Version (RTS2) is an open-source and automatic observatory-control system. However, all previous RTS2 applications were developed for small telescopes. This paper focuses on implementation of an RTS2-based camera-control system for the 32 CCDs of LAMOST. A virtual camera module inherited from the RTS2 camera module is built as a device component working on the RTS2 framework. To improve the controllability and robustness, a virtualized layer is designed using the master-slave software paradigm, and the virtual camera module is mapped to the 32 real cameras of LAMOST. The new system is deployed in the actual environment and experimentally tested. Finally, multiple observations are conducted using this new RTS2-framework-based control system. The new camera-control system is found to satisfy the requirements for automatic camera control in LAMOST. This is the first time that RTS2 has been applied to a large telescope, and provides a referential solution for full RTS2 introduction to the LAMOST observatory control system.

  18. Molecular confirmation of Maize rayado fino virus as the Brazilian corn streak virus

    OpenAIRE

    Hammond,Rosemarie Wahnbaeck; Bedendo,Ivan Paulo

    2005-01-01

    Maize rayado fino virus (MRFV), present in various countries in Latin America, has shown similarities to corn streak virus that occurs in Brazil, regarding pathogenic, serological and histological characteristics. In the current report both virus were molecularly compared to confirm the similarities between them. MRFV was identified by nucleic acid hybridization in samples of maize tissues exhibiting symptoms of "corn stunt" disease, collected from two Brazilian States - São Paulo and Minas G...

  19. TIFR Near Infrared Imaging Camera-II on the 3.6 m Devasthal Optical Telescope

    Science.gov (United States)

    Baug, T.; Ojha, D. K.; Ghosh, S. K.; Sharma, S.; Pandey, A. K.; Kumar, Brijesh; Ghosh, Arpan; Ninan, J. P.; Naik, M. B.; D’Costa, S. L. A.; Poojary, S. S.; Sandimani, P. R.; Shah, H.; Krishna Reddy, B.; Pandey, S. B.; Chand, H.

    Tata Institute of Fundamental Research (TIFR) Near Infrared Imaging Camera-II (TIRCAM2) is a closed-cycle Helium cryo-cooled imaging camera equipped with a Raytheon 512×512 pixels InSb Aladdin III Quadrant focal plane array (FPA) having sensitivity to photons in the 1-5μm wavelength band. In this paper, we present the performance of the camera on the newly installed 3.6m Devasthal Optical Telescope (DOT) based on the calibration observations carried out during 2017 May 11-14 and 2017 October 7-31. After the preliminary characterization, the camera has been released to the Indian and Belgian astronomical community for science observations since 2017 May. The camera offers a field-of-view (FoV) of ˜86.5‧‧×86.5‧‧ on the DOT with a pixel scale of 0.169‧‧. The seeing at the telescope site in the near-infrared (NIR) bands is typically sub-arcsecond with the best seeing of ˜0.45‧‧ realized in the NIR K-band on 2017 October 16. The camera is found to be capable of deep observations in the J, H and K bands comparable to other 4m class telescopes available world-wide. Another highlight of this camera is the observational capability for sources up to Wide-field Infrared Survey Explorer (WISE) W1-band (3.4μm) magnitudes of 9.2 in the narrow L-band (nbL; λcen˜ 3.59μm). Hence, the camera could be a good complementary instrument to observe the bright nbL-band sources that are saturated in the Spitzer-Infrared Array Camera (IRAC) ([3.6] ≲ 7.92 mag) and the WISE W1-band ([3.4] ≲ 8.1 mag). Sources with strong polycyclic aromatic hydrocarbon (PAH) emission at 3.3μm are also detected. Details of the observations and estimated parameters are presented in this paper.

  20. Time-resolved measurements with streaked diffraction patterns from electrons generated in laser plasma wakefield

    Science.gov (United States)

    He, Zhaohan; Nees, John; Hou, Bixue; Krushelnick, Karl; Thomas, Alec; Beaurepaire, Benoît; Malka, Victor; Faure, Jérôme

    2013-10-01

    Femtosecond bunches of electrons with relativistic to ultra-relativistic energies can be robustly produced in laser plasma wakefield accelerators (LWFA). Scaling the electron energy down to sub-relativistic and MeV level using a millijoule laser system will make such electron source a promising candidate for ultrafast electron diffraction (UED) applications due to the intrinsic short bunch duration and perfect synchronization with the optical pump. Recent results of electron diffraction from a single crystal gold foil, using LWFA electrons driven by 8-mJ, 35-fs laser pulses at 500 Hz, will be presented. The accelerated electrons were collimated with a solenoid magnetic lens. By applying a small-angle tilt to the magnetic lens, the diffraction pattern can be streaked such that the temporal evolution is separated spatially on the detector screen after propagation. The observable time window and achievable temporal resolution are studied in pump-probe measurements of photo-induced heating on the gold foil.

  1. FOREX-A Fiber Optics Diagnostic System For Study Of Materials At High Temperatures And Pressures

    Science.gov (United States)

    Smith, D. E.; Roeske, F.

    1983-03-01

    We have successfully fielded a Fiber Optics Radiation EXperiment system (FOREX) designed for measuring material properties at high temperatures and pressures on an underground nuclear test. The system collects light from radiating materials and transmits it through several hundred meters of optical fibers to a recording station consisting of a streak camera with film readout. The use of fiber optics provides a faster time response than can presently be obtained with equalized coaxial cables over comparable distances. Fibers also have significant cost and physical size advantages over coax cables. The streak camera achieves a much higher information density than an equivalent oscilloscope system, and it also serves as the light detector. The result is a wide bandwidth high capacity system that can be fielded at a relatively low cost in manpower, space, and materials. For this experiment, the streak camera had a 120 ns time window with a 1.2 ns time resolution. Dynamic range for the system was about 1000. Beam current statistical limitations were approximately 8% for a 0.3 ns wide data point at one decade above the threshold recording intensity.

  2. Gamma camera

    International Nuclear Information System (INIS)

    Tschunt, E.; Platz, W.; Baer, Ul; Heinz, L.

    1978-01-01

    A gamma camera has a plurality of exchangeable collimators, one of which is replaceably mounted in the ray inlet opening of the camera, while the others are placed on separate supports. Supports are swingably mounted upon a column one above the other

  3. Overexpression of rice black-streaked dwarf virus p7-1 in Arabidopsis results in male sterility due to non-dehiscent anthers.

    Directory of Open Access Journals (Sweden)

    Feng Sun

    Full Text Available Rice black-streaked dwarf virus (RBSDV, a member of the genus Fijivirus in the family Reoviridae, is propagatively transmitted by the small brown planthopper (Laodelphax striatellus Fallén. RBSDV causes rice black-streaked dwarf and maize rough dwarf diseases, which lead to severe yield losses in crops in China. Although several RBSDV proteins have been studied in detail, the functions of the nonstructural protein P7-1 are still largely unknown. To investigate the role of the P7-1 protein in virus pathogenicity, transgenic Arabidopsis thaliana plants were generated in which the P7-1 gene was expressed under the control of the 35S promoter. The RBSDV P7-1-transgenic Arabidopsis plants (named P7-1-OE were male sterility. Flowers and pollen from P7-1-transgenic plants were of normal size and shape, and anthers developed to the normal size but failed to dehisce. The non-dehiscent anthers observed in P7-1-OE were attributed to decreased lignin content in the anthers. Furthermore, the reactive oxygen species levels were quite low in the transgenic plants compared with the wild type. These results indicate that ectopic expression of the RBSDV P7-1 protein in A. thaliana causes male sterility, possibly through the disruption of the lignin biosynthesis and H2O2-dependent polymerization pathways.

  4. Overexpression of rice black-streaked dwarf virus p7-1 in Arabidopsis results in male sterility due to non-dehiscent anthers.

    Science.gov (United States)

    Sun, Feng; Yuan, Xia; Xu, Qiufang; Zhou, Tong; Fan, Yongjian; Zhou, Yijun

    2013-01-01

    Rice black-streaked dwarf virus (RBSDV), a member of the genus Fijivirus in the family Reoviridae, is propagatively transmitted by the small brown planthopper (Laodelphax striatellus Fallén). RBSDV causes rice black-streaked dwarf and maize rough dwarf diseases, which lead to severe yield losses in crops in China. Although several RBSDV proteins have been studied in detail, the functions of the nonstructural protein P7-1 are still largely unknown. To investigate the role of the P7-1 protein in virus pathogenicity, transgenic Arabidopsis thaliana plants were generated in which the P7-1 gene was expressed under the control of the 35S promoter. The RBSDV P7-1-transgenic Arabidopsis plants (named P7-1-OE) were male sterility. Flowers and pollen from P7-1-transgenic plants were of normal size and shape, and anthers developed to the normal size but failed to dehisce. The non-dehiscent anthers observed in P7-1-OE were attributed to decreased lignin content in the anthers. Furthermore, the reactive oxygen species levels were quite low in the transgenic plants compared with the wild type. These results indicate that ectopic expression of the RBSDV P7-1 protein in A. thaliana causes male sterility, possibly through the disruption of the lignin biosynthesis and H2O2-dependent polymerization pathways.

  5. Radiation-resistant camera tube

    International Nuclear Information System (INIS)

    Kuwahata, Takao; Manabe, Sohei; Makishima, Yasuhiro

    1982-01-01

    It was a long time ago that Toshiba launched on manufacturing black-and-white radiation-resistant camera tubes employing nonbrowning face-plate glass for ITV cameras used in nuclear power plants. Now in compliance with the increasing demand in nuclear power field, the Company is at grips with the development of radiation-resistant single color-camera tubes incorporating a color-stripe filter for color ITV cameras used under radiation environment. Herein represented are the results of experiments on characteristics of materials for single color-camera tubes and prospects for commercialization of the tubes. (author)

  6. Transverse blowup along bunch train caused by electron cloud in BEPC

    International Nuclear Information System (INIS)

    Liu Yudong; Guo Zhiyuan; Qin Qing; Wang Jiuqing; Zhao Zheng

    2006-01-01

    Electron cloud instability (ECI) may take place in a storage ring when the machine is operated with a multi-bunch positively charged beam. Transverse blowup due to electron cloud has been observed in some machines and is considered to be a major limit factor in the development of high current and high luminosity electron positron colliders. With a streak camera, the transverse blowup along the bunch train was first observed in an experiment at the Beijing Electron-Positron Collider (BEPC) and the simulation results were used to compared with the observation. (authors)

  7. Data-Acquisition Software for PSP/TSP Wind-Tunnel Cameras

    Science.gov (United States)

    Amer, Tahani R.; Goad, William K.

    2005-01-01

    Wing-Viewer is a computer program for acquisition and reduction of image data acquired by any of five different scientificgrade commercial electronic cameras used at Langley Research center to observe wind-tunnel models coated with pressure or temperature-sensitive paints (PSP/TSP). Wing-Viewer provides full automation of camera operation and acquisition of image data, and has limited data-preprocessing capability for quick viewing of the results of PSP/TSP test images. Wing- Viewer satisfies a requirement for a standard interface between all the cameras and a single personal computer: Written by use of Microsoft Visual C++ and the Microsoft Foundation Class Library as a framework, Wing-Viewer has the ability to communicate with the C/C++ software libraries that run on the controller circuit cards of all five cameras.

  8. Wheat streak mosaic virus coat protein is a determinant for vector transmission by the wheat curl mite

    Science.gov (United States)

    Wheat streak mosaic virus (WSMV; genus Tritimovirus; family Potyviridae), is transmitted by the wheat curl mite (Aceria tosichella Keifer). The requirement of coat protein (CP) for WSMV transmission by the wheat curl mite was examined using a series of viable deletion and point mutations. Mite trans...

  9. GRACE star camera noise

    Science.gov (United States)

    Harvey, Nate

    2016-08-01

    Extending results from previous work by Bandikova et al. (2012) and Inacio et al. (2015), this paper analyzes Gravity Recovery and Climate Experiment (GRACE) star camera attitude measurement noise by processing inter-camera quaternions from 2003 to 2015. We describe a correction to star camera data, which will eliminate a several-arcsec twice-per-rev error with daily modulation, currently visible in the auto-covariance function of the inter-camera quaternion, from future GRACE Level-1B product releases. We also present evidence supporting the argument that thermal conditions/settings affect long-term inter-camera attitude biases by at least tens-of-arcsecs, and that several-to-tens-of-arcsecs per-rev star camera errors depend largely on field-of-view.

  10. [Evaluation of Iris Morphology Viewed through Stromal Edematous Corneas by Infrared Camera].

    Science.gov (United States)

    Kobayashi, Masaaki; Morishige, Naoyuki; Morita, Yukiko; Yamada, Naoyuki; Kobayashi, Motomi; Sonoda, Koh-Hei

    2016-02-01

    We reported that the application of infrared camera enables us to observe iris morphology in Peters' anomaly through edematous corneas. To observe the iris morphology in bullous keratopathy or failure grafts with an infrared camera. Eleven bullous keratopathy or failure grafts subjects (6 men and 5 women, mean age ± SD; 72.7 ± 13.0 years old) were enrolled in this study. The iris morphology was observed by applying visible light mode and near infrared light mode of infrared camera (MeibomPen). The detectability of pupil shapes, iris patterns and presence of iridectomy was evaluated. Infrared mode observation enabled us to detect the pupil shapes in 11 out of 11 cases, iris patterns in 3 out of 11 cases, and presence of iridetomy in 9 out of 11 cases although visible light mode observation could not detect any iris morphological changes. Applying infrared optics was valuable for observation of the iris morphology through stromal edematous corneas.

  11. A new high-speed IR camera system

    Science.gov (United States)

    Travis, Jeffrey W.; Shu, Peter K.; Jhabvala, Murzy D.; Kasten, Michael S.; Moseley, Samuel H.; Casey, Sean C.; Mcgovern, Lawrence K.; Luers, Philip J.; Dabney, Philip W.; Kaipa, Ravi C.

    1994-01-01

    A multi-organizational team at the Goddard Space Flight Center is developing a new far infrared (FIR) camera system which furthers the state of the art for this type of instrument by the incorporating recent advances in several technological disciplines. All aspects of the camera system are optimized for operation at the high data rates required for astronomical observations in the far infrared. The instrument is built around a Blocked Impurity Band (BIB) detector array which exhibits responsivity over a broad wavelength band and which is capable of operating at 1000 frames/sec, and consists of a focal plane dewar, a compact camera head electronics package, and a Digital Signal Processor (DSP)-based data system residing in a standard 486 personal computer. In this paper we discuss the overall system architecture, the focal plane dewar, and advanced features and design considerations for the electronics. This system, or one derived from it, may prove useful for many commercial and/or industrial infrared imaging or spectroscopic applications, including thermal machine vision for robotic manufacturing, photographic observation of short-duration thermal events such as combustion or chemical reactions, and high-resolution surveillance imaging.

  12. Radioactive sampler observation device

    International Nuclear Information System (INIS)

    Tanaka, Norihiko; Saito, Norihisa.

    1996-01-01

    When an object of observation is a fuel rod and if a specimen in a fuel pool is small, it takes much labor for the observation and micro-observation images at a high ratio can not be displayed. A pipe for containing an observing camera in a water-sealed state, a jack capable of adjusting the focus of the observation camera by remote control and a horizontal bed capable of controlling the position of the observation camera for observing the specimen are disposed on a rail formed on lead block shielding walls. The magnification ratio for the observation can be increased by exchanging a die for securing the specimen and a lens, and a transparent acrylic resin plate, or a transparent lead-incorporated glass plate is joined to the bottom of the pipe. Since the sampled specimen can be observed as it is irrespective of the shape or the size of the specimen to be observed, danger of radiation exposure caused such as upon cutting, transportation or fabrication of the radioactive specimen can be reduced. Further, observation underwater can be conducted by the water sealing treatment of the pipe for the observing camera. (N.H.)

  13. High speed photography, videography, and photonics V; Proceedings of the Meeting, San Diego, CA, Aug. 17-19, 1987

    International Nuclear Information System (INIS)

    Johnson, H.C.

    1988-01-01

    Recent advances in high-speed optical and electrooptic devices are discussed in reviews and reports. Topics examined include data quantification and related technologies, high-speed photographic applications and instruments, flash and cine radiography, and novel ultrafast methods. Also considered are optical streak technology, high-speed videographic and photographic equipment, and X-ray streak cameras. Extensive diagrams, drawings, graphs, sample images, and tables of numerical data are provided

  14. High resolution time- and 2-dimensional space-resolved x-ray imaging of plasmas at NOVA

    International Nuclear Information System (INIS)

    Landen, O.L.

    1992-01-01

    A streaked multiple pinhole camera technique, first used by P. Choi et al. to record time- and 2-D space-resolved soft X-ray images of plasma pinches, has been implemented on laser plasmas at NOVA. The instrument is particularly useful for time-resolved imaging of small sources ( 2.5 key imaging, complementing the existing 1--3 key streaked X-ray microscope capabilities at NOVA

  15. High speed photography, videography, and photonics V; Proceedings of the Meeting, San Diego, CA, Aug. 17-19, 1987

    Science.gov (United States)

    Johnson, Howard C. (Editor)

    1988-01-01

    Recent advances in high-speed optical and electrooptic devices are discussed in reviews and reports. Topics examined include data quantification and related technologies, high-speed photographic applications and instruments, flash and cine radiography, and novel ultrafast methods. Also considered are optical streak technology, high-speed videographic and photographic equipment, and X-ray streak cameras. Extensive diagrams, drawings, graphs, sample images, and tables of numerical data are provided.

  16. Genomic and phylogenetic evidence that Maize rough dwarf and Rice black-streaked dwarf fijiviruses should be classified as different geographic strains of a single species.

    Science.gov (United States)

    Xie, L; Lv, M-F; Yang, J; Chen, J-P; Zhang, H-M

    Maize rough dwarf disease (MRDD) has long been known as one of the most devastating viral diseases of maize worldwide and is caused by single or complex infection by four fijiviruses: Maize rough dwarf virus (MRDV) in Europe and the Middle East, Mal de Rio Cuarto virus (MRCV) in South America, rice black-streaked dwarf virus (RBSDV), and Southern rice black-streaked dwarf virus (SRBSDV or Rice black-streaked dwarf virus 2, RBSDV-2) in East Asia. These are currently classified as four distinct species in the genus Fijivirus, family Reoviridae, but their taxonomic status has been questioned. To help resolve this, the nucleotide sequences of the ten genomic segments of an Italian isolate of MRDV have been determined, providing the first complete genomic sequence of this virus. Its genome has 29144 nucleotides and is similar in organization to those of RBSDV, SRBSDV, and MRCV. The 13 ORFs always share highest identities (81.3-97.2%) with the corresponding ORFs of RBSDV and phylogenetic analyses of the different genome segments and ORFs all confirm that MRDV clusters most closely with RBSDV and that MRCV and SRBSDV are slightly more distantly related. The results suggest that MRDV and RBSDV should be classified as different geographic strains of the same virus species and we suggest the name cereal black-streaked dwarf fijivirus (CBSDV) for consideration.

  17. NSTX Tangential Divertor Camera

    International Nuclear Information System (INIS)

    Roquemore, A.L.; Ted Biewer; Johnson, D.; Zweben, S.J.; Nobuhiro Nishino; Soukhanovskii, V.A.

    2004-01-01

    Strong magnetic field shear around the divertor x-point is numerically predicted to lead to strong spatial asymmetries in turbulence driven particle fluxes. To visualize the turbulence and associated impurity line emission near the lower x-point region, a new tangential observation port has been recently installed on NSTX. A reentrant sapphire window with a moveable in-vessel mirror images the divertor region from the center stack out to R 80 cm and views the x-point for most plasma configurations. A coherent fiber optic bundle transmits the image through a remotely selected filter to a fast camera, for example a 40500 frames/sec Photron CCD camera. A gas puffer located in the lower inboard divertor will localize the turbulence in the region near the x-point. Edge fluid and turbulent codes UEDGE and BOUT will be used to interpret impurity and deuterium emission fluctuation measurements in the divertor

  18. OCAMS: The OSIRIS-REx Camera Suite

    Science.gov (United States)

    Rizk, B.; Drouet d'Aubigny, C.; Golish, D.; Fellows, C.; Merrill, C.; Smith, P.; Walker, M. S.; Hendershot, J. E.; Hancock, J.; Bailey, S. H.; DellaGiustina, D. N.; Lauretta, D. S.; Tanner, R.; Williams, M.; Harshman, K.; Fitzgibbon, M.; Verts, W.; Chen, J.; Connors, T.; Hamara, D.; Dowd, A.; Lowman, A.; Dubin, M.; Burt, R.; Whiteley, M.; Watson, M.; McMahon, T.; Ward, M.; Booher, D.; Read, M.; Williams, B.; Hunten, M.; Little, E.; Saltzman, T.; Alfred, D.; O'Dougherty, S.; Walthall, M.; Kenagy, K.; Peterson, S.; Crowther, B.; Perry, M. L.; See, C.; Selznick, S.; Sauve, C.; Beiser, M.; Black, W.; Pfisterer, R. N.; Lancaster, A.; Oliver, S.; Oquest, C.; Crowley, D.; Morgan, C.; Castle, C.; Dominguez, R.; Sullivan, M.

    2018-02-01

    The OSIRIS-REx Camera Suite (OCAMS) will acquire images essential to collecting a sample from the surface of Bennu. During proximity operations, these images will document the presence of satellites and plumes, record spin state, enable an accurate model of the asteroid's shape, and identify any surface hazards. They will confirm the presence of sampleable regolith on the surface, observe the sampling event itself, and image the sample head in order to verify its readiness to be stowed. They will document Bennu's history as an example of early solar system material, as a microgravity body with a planetesimal size-scale, and as a carbonaceous object. OCAMS is fitted with three cameras. The MapCam will record color images of Bennu as a point source on approach to the asteroid in order to connect Bennu's ground-based point-source observational record to later higher-resolution surface spectral imaging. The SamCam will document the sample site before, during, and after it is disturbed by the sample mechanism. The PolyCam, using its focus mechanism, will observe the sample site at sub-centimeter resolutions, revealing surface texture and morphology. While their imaging requirements divide naturally between the three cameras, they preserve a strong degree of functional overlap. OCAMS and the other spacecraft instruments will allow the OSIRIS-REx mission to collect a sample from a microgravity body on the same visit during which it was first optically acquired from long range, a useful capability as humanity reaches out to explore near-Earth, Main-Belt and Jupiter Trojan asteroids.

  19. Design and Construction of an X-ray Lightning Camera

    Science.gov (United States)

    Schaal, M.; Dwyer, J. R.; Rassoul, H. K.; Uman, M. A.; Jordan, D. M.; Hill, J. D.

    2010-12-01

    A pinhole-type camera was designed and built for the purpose of producing high-speed images of the x-ray emissions from rocket-and-wire-triggered lightning. The camera consists of 30 7.62-cm diameter NaI(Tl) scintillation detectors, each sampling at 10 million frames per second. The steel structure of the camera is encased in 1.27-cm thick lead, which blocks x-rays that are less than 400 keV, except through a 7.62-cm diameter “pinhole” aperture located at the front of the camera. The lead and steel structure is covered in 0.16-cm thick aluminum to block RF noise, water and light. All together, the camera weighs about 550-kg and is approximately 1.2-m x 0.6-m x 0.6-m. The image plane, which is adjustable, was placed 32-cm behind the pinhole aperture, giving a field of view of about ±38° in both the vertical and horizontal directions. The elevation of the camera is adjustable between 0 and 50° from horizontal and the camera may be pointed in any azimuthal direction. In its current configuration, the camera’s angular resolution is about 14°. During the summer of 2010, the x-ray camera was located 44-m from the rocket-launch tower at the UF/Florida Tech International Center for Lightning Research and Testing (ICLRT) at Camp Blanding, FL and several rocket-triggered lightning flashes were observed. In this presentation, I will discuss the design, construction and operation of this x-ray camera.

  20. Gamma camera

    International Nuclear Information System (INIS)

    Schlosser, P.A.; Steidley, J.W.

    1980-01-01

    The design of a collimation system for a gamma camera for use in nuclear medicine is described. When used with a 2-dimensional position sensitive radiation detector, the novel system can produce superior images than conventional cameras. The optimal thickness and positions of the collimators are derived mathematically. (U.K.)

  1. Picosecond camera

    International Nuclear Information System (INIS)

    Decroisette, Michel

    A Kerr cell activated by infrared pulses of a model locked Nd glass laser, acts as an ultra-fast and periodic shutter, with a few p.s. opening time. Associated with a S.T.L. camera, it gives rise to a picosecond camera allowing us to study very fast effects [fr

  2. Determination of frequencies of oscillations of cloud cavitation on a 2-D hydrofoil from high-speed camera observations

    Czech Academy of Sciences Publication Activity Database

    Zima, Patrik; Fürst, T.; Sedlář, M.; Komárek, M.; Huzlík, R.

    2016-01-01

    Roč. 28, č. 3 (2016), s. 369-378 ISSN 1001-6058 R&D Projects: GA ČR GA13-23550S Institutional support: RVO:61388998 Keywords : unsteady cavitation * oscillation frequency * high-speed camera observation Subject RIV: BK - Fluid Dynamics Impact factor: 1.174, year: 2016 http://ac.els-cdn.com/S1001605816606406/1-s2.0-S1001605816606406-main.pdf?_tid=dee3b8f4-4a62-11e6-9d83-00000aacb361&acdnat=1468570098_ce8b727c766e0f96ee20d505e7058102

  3. Camera-cinematography of the heart

    International Nuclear Information System (INIS)

    Adam, W.E.; Meyer, G.; Bitter, F.; Kampmann, H.; Bargon, G.; Stauch, M.; Ulm Univ.

    1975-01-01

    By 'camera-cinematography' of the heart, we mean an isotope method which permits detailed observation of cardiac mechanics without the use of a catheter. All that is necessary is an intravenous injection of 10 to 15 mCisup(99m)Tc human serum albumin followed after ten minutes by a five to ten minute period of observation with a scintillation camera. At this time the isotope has become distributed in the blood. Variations in the precordial impulses correspond with intra-cardiac changes of blood volume during a cardiac cycle. Analysis of the R-wave provides adequate information of cyclical volume changes in limited portions of the heart. This is achieved by a monitor with a pseudo-3-dimensional display; contraction and relaxation of the myocardium can be shown for any chosen longitudinal or horizontal diameter of the heart. Our programme allows simultaneous presentation of the movement of any point on the myocardium as a time-activity curve. The method is recommended as an addition to chest radiography, heart screening or cardiac kymography before carrying out cardiac catheterisation. (orig.) [de

  4. Introgression of chromosome segments from multiple alien species in wheat breeding lines with wheat streak mosaic virus resistance

    Science.gov (United States)

    Pyramiding of alien-derived Wheat streak mosaic virus (WSMV) resistance and resistance enhancing genes in wheat is a costeffective and environmentally safe strategy for disease control. PCR-based markers and cytogenetic analysis with genomic in situ hybridisation were applied to identify alien chrom...

  5. Failure Waves in Cylindrical Glass Bars

    Science.gov (United States)

    Cazamias, James U.; Bless, Stephan J.; Marder, Michael P.

    1997-07-01

    Failure waves, a propagating front separating virgin and comminuted material, have been receiving a fair amount of attention the last couple of years. While most scientists have been looking at failure waves in plate impact geometries, we have conducted a series of experiments on Pyrex bars. In this paper, we present two types of photographic data from a series of tests. A streak camera was used to determine velocities of the failure front as a function of impact stress. A polaroid camera and a flash lamp provide detailed pictures of the actual event. Attempts were made to observe failure waves in amorphous quartz and acrylic.

  6. A fast framing camera system for observation of acceleration and ablation of cryogenic hydrogen pellet in ASDEX Upgrade plasmas

    International Nuclear Information System (INIS)

    Kocsis, G.; Kalvin, S.; Veres, G.; Cierpka, P.; Lang, P.T.; Neuhauser, J.; Wittman, C.; ASDEX Upgrade Team

    2004-01-01

    An observation system using fast digital cameras was developed to measure a cryogenic hydrogen pellet's cloud structure, trajectory, and velocity changes during its ablation in ASDEX Upgrade plasmas. In this article the system, the applied numerical methods, and the results are presented. The three-dimensional pellet trajectory and velocity components were reconstructed from images of observations from two different directions. Pellet acceleration both in the radial and toroidal directions was detected. The pellet cloud distribution was measured with high spatio-temporal resolution. The cloud surrounding the pellet was found to be elongated along the magnetic field lines. Its typical size is 5-7 cm along the field lines and 2 cm in the perpendicular directions. A cloud extension in the poloidal direction was also observed which may be related to the drift of the detached part of the cloud

  7. The turbulent life of juvenile icebergs: Observations from an array of high-rate time-lapse cameras in LeConte Bay, Alaska

    Science.gov (United States)

    Kienholz, C.; Amundson, J. M.; Jackson, R. H.; Motyka, R. J.; Nash, J. D.; Sutherland, D.

    2017-12-01

    Tidewater glacier behavior is driven by poorly understood processes occurring at the ice-ocean interface, including sedimentation and erosion, iceberg calving, and submarine melting. These processes are inherently difficult to observe, calling for innovative field techniques and numerical models. As part of a multi-year field effort to constrain ocean-glacier heat and mass exchange, we deployed an array of high-rate time-lapse cameras (sampling intervals between 15 seconds and 2 minutes) to monitor the terminus of LeConte Glacier and its proglacial fjord. The camera array has operated continuously for more than a year. Our high sampling rates enable tracking of iceberg motion with optical flow algorithms, which have been used widely in computer vision but less so in glaciology and oceanography. Such algorithms track individual features (e.g., corners of icebergs), which is ideal for iceberg-rich fjords, where motion can vary substantially over short temporal and spatial scales (e.g., due to complex surface currents or different iceberg sizes). We process our data to quantify subdaily to seasonal patterns in surface currents and relate them to forcing from tides, wind, and glacier runoff. Flow is most variable close to the glacier terminus due to frequent calving events and turbulent plume dynamics. Farther down fjord, more consistent patterns emerge, driven by tides, wind, and runoff and altered by fjord geometry. Our tracking results compare favorably to and complement our Acoustic Doppler Current Profiler measurements from boats and moorings. Given their high spatial and temporal resolution, our observations will place important surface constraints on forthcoming hydrodynamic modeling efforts. The deployment of the cameras in a harsh environment and the corresponding image processing provided an opportunity to test hardware and software thoroughly, which will prove useful for similar systems at other glaciers.

  8. Reducing the Variance of Intrinsic Camera Calibration Results in the ROS Camera_Calibration Package

    Science.gov (United States)

    Chiou, Geoffrey Nelson

    The intrinsic calibration of a camera is the process in which the internal optical and geometric characteristics of the camera are determined. If accurate intrinsic parameters of a camera are known, the ray in 3D space that every point in the image lies on can be determined. Pairing with another camera allows for the position of the points in the image to be calculated by intersection of the rays. Accurate intrinsics also allow for the position and orientation of a camera relative to some world coordinate system to be calculated. These two reasons for having accurate intrinsic calibration for a camera are especially important in the field of industrial robotics where 3D cameras are frequently mounted on the ends of manipulators. In the ROS (Robot Operating System) ecosystem, the camera_calibration package is the default standard for intrinsic camera calibration. Several researchers from the Industrial Robotics & Automation division at Southwest Research Institute have noted that this package results in large variances in the intrinsic parameters of the camera when calibrating across multiple attempts. There are also open issues on this matter in their public repository that have not been addressed by the developers. In this thesis, we confirm that the camera_calibration package does indeed return different results across multiple attempts, test out several possible hypothesizes as to why, identify the reason, and provide simple solution to fix the cause of the issue.

  9. Commercialization of radiation tolerant camera

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Bum; Choi, Young Soo; Kim, Sun Ku; Lee, Jong Min; Cha, Bung Hun; Lee, Nam Ho; Byun, Eiy Gyo; Yoo, Seun Wook; Choi, Bum Ki; Yoon, Sung Up; Kim, Hyun Gun; Sin, Jeong Hun; So, Suk Il

    1999-12-01

    In this project, radiation tolerant camera which tolerates 10{sup 6} - 10{sup 8} rad total dose is developed. In order to develop radiation tolerant camera, radiation effect of camera components was examined and evaluated, and camera configuration was studied. By the result of evaluation, the components were decided and design was performed. Vidicon tube was selected to use by image sensor and non-browning optics and camera driving circuit were applied. The controller needed for CCTV camera system, lens, light, pan/tilt controller, was designed by the concept of remote control. And two type of radiation tolerant camera were fabricated consider to use in underwater environment or normal environment. (author)

  10. Commercialization of radiation tolerant camera

    International Nuclear Information System (INIS)

    Lee, Yong Bum; Choi, Young Soo; Kim, Sun Ku; Lee, Jong Min; Cha, Bung Hun; Lee, Nam Ho; Byun, Eiy Gyo; Yoo, Seun Wook; Choi, Bum Ki; Yoon, Sung Up; Kim, Hyun Gun; Sin, Jeong Hun; So, Suk Il

    1999-12-01

    In this project, radiation tolerant camera which tolerates 10 6 - 10 8 rad total dose is developed. In order to develop radiation tolerant camera, radiation effect of camera components was examined and evaluated, and camera configuration was studied. By the result of evaluation, the components were decided and design was performed. Vidicon tube was selected to use by image sensor and non-browning optics and camera driving circuit were applied. The controller needed for CCTV camera system, lens, light, pan/tilt controller, was designed by the concept of remote control. And two type of radiation tolerant camera were fabricated consider to use in underwater environment or normal environment. (author)

  11. Cameras in mobile phones

    Science.gov (United States)

    Nummela, Ville; Viinikanoja, Jarkko; Alakarhu, Juha

    2006-04-01

    One of the fastest growing markets in consumer markets today are camera phones. During past few years total volume has been growing fast and today millions of mobile phones with camera will be sold. At the same time resolution and functionality of the cameras has been growing from CIF towards DSC level. From camera point of view the mobile world is an extremely challenging field. Cameras should have good image quality but in small size. They also need to be reliable and their construction should be suitable for mass manufacturing. All components of the imaging chain should be well optimized in this environment. Image quality and usability are the most important parameters to user. The current trend of adding more megapixels to cameras and at the same time using smaller pixels is affecting both. On the other hand reliability and miniaturization are key drivers for product development as well as the cost. In optimized solution all parameters are in balance but the process of finding the right trade-offs is not an easy task. In this paper trade-offs related to optics and their effects to image quality and usability of cameras are discussed. Key development areas from mobile phone camera point of view are also listed.

  12. Practical issues of retrieving isolated attosecond pulses

    International Nuclear Information System (INIS)

    Wang He; Chini, Michael; Khan, Sabih D; Chen, Shouyuan; Gilbertson, Steve; Feng Ximao; Mashiko, Hiroki; Chang Zenghu

    2009-01-01

    The attosecond streaking technique is used for the characterization of isolated extreme ultraviolet (XUV) attosecond pulses. This type of measurement suffers from low photoelectron counts in the streaked spectrogram, and is thus susceptible to shot noise. For the retrieval of few- or mono-cycle attosecond pulses, high-intensity streaking laser fields are required, which cause the energy spectrum of above-threshold ionized (ATI) electrons to overlap with that of the streaked photoelectrons. It is found by using the principal component generalized projections algorithm that the XUV attosecond pulse can accurately be retrieved for simulated and experimental spectrograms with a peak value of 50 or more photoelectron counts. Also, the minimum streaking intensity is found to be more than 50 times smaller than that required by the classical streaking camera for retrieval of pulses with a spectral bandwidth supporting 90 as transform-limited pulse durations. Furthermore, spatial variation of the streaking laser intensity, collection angle of streaked electrons and time delay jitter between the XUV pulse and streaking field can degrade the quality of the streaked spectrogram. We find that even when the XUV and streaking laser focal spots are comparable in size, the streaking electrons are collected from a 4π solid angle, or the delay fluctuates by more than the attosecond pulse duration, the attosecond pulses can still be accurately retrieved. In order to explain the insusceptibility of the streaked spectrogram to these factors, the linearity of the streaked spectrogram with respect to the streaking field is derived under the saddle point approximation.

  13. Major QTL Conferring Resistance to Rice Bacterial Leaf Streak

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Bacterial leaf streak (BLS) is one of the important limiting factors to rice production in southern China and other tropical and sub-tropical areas in Asia. Resistance to BLS was found to be a quantitative trait and no major resistant gene was located in rice until date. In the present study, a new major quantitative trait locus (QTL) conferring resistance to BLS was identified from a highly resistant variety Dular by the employment of Dular/Balilla (DB) and Dular/IR24 (DI) segregation populations and was designated qBLSR-11-1. This QTL was located between the simple sequence repeat (SSR) markers RM120 and RM441 on chromosome 11 and could account for 18.1-21.7% and 36.3% of the variance in DB and DI populations, respectively. The genetic pattern of rice resistance to BLS was discussed.

  14. Chirp of monolithic colliding pulse mode-locked diode lasers

    DEFF Research Database (Denmark)

    Hofmann, M.; Bischoff, S.; Franck, Thorkild

    1997-01-01

    Spectrally resolved streak camera measurements of picosecond pulses emitted by hybridly colliding pulse mode-locked (CPM) laser diodes are presented in this letter. Depending on the modulation frequency both blue-chirped (upchirped) and red-chirped (downchirped) pulses can be observed. The two...... different regimes and the transition between them are characterized experimentally and the behavior is explained on the basis of our model for the CPM laser dynamics. (C) 1997 American Institute of Physics....

  15. Advantages of computer cameras over video cameras/frame grabbers for high-speed vision applications

    Science.gov (United States)

    Olson, Gaylord G.; Walker, Jo N.

    1997-09-01

    Cameras designed to work specifically with computers can have certain advantages in comparison to the use of cameras loosely defined as 'video' cameras. In recent years the camera type distinctions have become somewhat blurred, with a great presence of 'digital cameras' aimed more at the home markets. This latter category is not considered here. The term 'computer camera' herein is intended to mean one which has low level computer (and software) control of the CCD clocking. These can often be used to satisfy some of the more demanding machine vision tasks, and in some cases with a higher rate of measurements than video cameras. Several of these specific applications are described here, including some which use recently designed CCDs which offer good combinations of parameters such as noise, speed, and resolution. Among the considerations for the choice of camera type in any given application would be such effects as 'pixel jitter,' and 'anti-aliasing.' Some of these effects may only be relevant if there is a mismatch between the number of pixels per line in the camera CCD and the number of analog to digital (A/D) sampling points along a video scan line. For the computer camera case these numbers are guaranteed to match, which alleviates some measurement inaccuracies and leads to higher effective resolution.

  16. Divergence-ratio axi-vision camera (Divcam): A distance mapping camera

    International Nuclear Information System (INIS)

    Iizuka, Keigo

    2006-01-01

    A novel distance mapping camera the divergence-ratio axi-vision camera (Divcam) is proposed. The decay rate of the illuminating light with distance due to the divergence of the light is used as means of mapping the distance. Resolutions of 10 mm over a range of meters and 0.5 mm over a range of decimeters were achieved. The special features of this camera are its high resolution real-time operation, simplicity, compactness, light weight, portability, and yet low fabrication cost. The feasibility of various potential applications is also included

  17. Thermal Cameras and Applications

    DEFF Research Database (Denmark)

    Gade, Rikke; Moeslund, Thomas B.

    2014-01-01

    Thermal cameras are passive sensors that capture the infrared radiation emitted by all objects with a temperature above absolute zero. This type of camera was originally developed as a surveillance and night vision tool for the military, but recently the price has dropped, significantly opening up...... a broader field of applications. Deploying this type of sensor in vision systems eliminates the illumination problems of normal greyscale and RGB cameras. This survey provides an overview of the current applications of thermal cameras. Applications include animals, agriculture, buildings, gas detection......, industrial, and military applications, as well as detection, tracking, and recognition of humans. Moreover, this survey describes the nature of thermal radiation and the technology of thermal cameras....

  18. Radiation camera exposure control

    International Nuclear Information System (INIS)

    Martone, R.J.; Yarsawich, M.; Wolczek, W.

    1976-01-01

    A system and method for governing the exposure of an image generated by a radiation camera to an image sensing camera is disclosed. The exposure is terminated in response to the accumulation of a predetermined quantity of radiation, defining a radiation density, occurring in a predetermined area. An index is produced which represents the value of that quantity of radiation whose accumulation causes the exposure termination. The value of the predetermined radiation quantity represented by the index is sensed so that the radiation camera image intensity can be calibrated to compensate for changes in exposure amounts due to desired variations in radiation density of the exposure, to maintain the detectability of the image by the image sensing camera notwithstanding such variations. Provision is also made for calibrating the image intensity in accordance with the sensitivity of the image sensing camera, and for locating the index for maintaining its detectability and causing the proper centering of the radiation camera image

  19. Adapting Virtual Camera Behaviour

    DEFF Research Database (Denmark)

    Burelli, Paolo

    2013-01-01

    In a three-dimensional virtual environment aspects such as narrative and interaction completely depend on the camera since the camera defines the player’s point of view. Most research works in automatic camera control aim to take the control of this aspect from the player to automatically gen- er...

  20. Automated Meteor Detection by All-Sky Digital Camera Systems

    Science.gov (United States)

    Suk, Tomáš; Šimberová, Stanislava

    2017-12-01

    We have developed a set of methods to detect meteor light traces captured by all-sky CCD cameras. Operating at small automatic observatories (stations), these cameras create a network spread over a large territory. Image data coming from these stations are merged in one central node. Since a vast amount of data is collected by the stations in a single night, robotic storage and analysis are essential to processing. The proposed methodology is adapted to data from a network of automatic stations equipped with digital fish-eye cameras and includes data capturing, preparation, pre-processing, analysis, and finally recognition of objects in time sequences. In our experiments we utilized real observed data from two stations.

  1. Characterestics of pico-second single bunch at the S-band linear accelerator

    International Nuclear Information System (INIS)

    Uesaka, Mitsuru; Kozawa, Takahiro; Kobayashi, Toshiaki; Ueda, Toru; Miya, Kenzo

    1994-01-01

    Measurement of the bunch structure of a pico-second single bunch was performed using a femto-second streak camera at the S-band linear accelerator of the University of Tokyo. The aim of this research is to investigate the feasibility of the generation of a femto-second single bunch at the S-band linac. The details of the bunch structure and energy spectrum of an original single bunch were precisely investigated in several operation modes where the RF phases in accelerating tubes and a prebuncher were varied. The femto-second streak camera was utilized to measure the bunch structure by one shot via Cherenkov radiation emitted by the electrons in the bunch. Next, an experiment for magnetic pulse compression of the original single bunch was carried out. Pulse shapes of the compressed bunchs for different energy modulation were also obtained by measuring Cherenkov radiation by one shot using the femto-second streak camera. Prior to the experiment, numerical tracking analysis to determine operating parameters for the magnetic pulse compression was also done. Measured pulse widths were compared with calculated ones. Finally, a 2 ps (full width at half maximum; FWHM) single bunch with an electric charge of 0.3 nC could be generated by the magnetic pulse compression. ((orig.))

  2. Hubble Space Telescope Wide Field Planetary Camera 2 Observations of Neptune

    Science.gov (United States)

    1995-01-01

    Two groups have recently used the Hubble Space Telescope (HST) Wide Field Planetary Camera 2 (WFPC 2) to acquire new high-resolution images of the planet Neptune. Members of the WFPC-2 Science Team, lead by John Trauger, acquired the first series of images on 27 through 29 June 1994. These were the highest resolution images of Neptune taken since the Voyager-2 flyby in August of 1989. A more comprehensive program is currently being conducted by Heidi Hammel and Wes Lockwood. These two sets of observations are providing a wealth of new information about the structure, composition, and meteorology of this distant planet's atmosphere.Neptune is currently the most distant planet from the sun, with an orbital radius of 4.5 billion kilometers (2.8 billion miles, or 30 Astronomical Units). Even though its diameter is about four times that of the Earth (49,420 vs. 12,742 km), ground-based telescopes reveal a tiny blue disk that subtends less than 1/1200 of a degree (2.3 arc-seconds). Neptune has therefore been a particularly challenging object to study from the ground because its disk is badly blurred by the Earth's atmosphere. In spite of this, ground-based astronomers had learned a great deal about this planet since its position was first predicted by John C. Adams and Urbain Leverrier in 1845. For example, they had determined that Neptune was composed primarily of hydrogen and helium gas, and that its blue color caused by the presence of trace amounts of the gas methane, which absorbs red light. They had also detected bright cloud features whose brightness changed with time, and tracked these clouds to infer a rotation period between 17 and 22 hours.When the Voyager-2 spacecraft flew past the Neptune in 1989, its instruments revealed a surprising array of meteorological phenomena, including strong winds, bright, high-altitude clouds, and two large dark spots attributed to long-lived giant storm systems. These bright clouds and dark spots were tracked as they moved

  3. Automatic fog detection for public safety by using camera images

    Science.gov (United States)

    Pagani, Giuliano Andrea; Roth, Martin; Wauben, Wiel

    2017-04-01

    Fog and reduced visibility have considerable impact on the performance of road, maritime, and aeronautical transportation networks. The impact ranges from minor delays to more serious congestions or unavailability of the infrastructure and can even lead to damage or loss of lives. Visibility is traditionally measured manually by meteorological observers using landmarks at known distances in the vicinity of the observation site. Nowadays, distributed cameras facilitate inspection of more locations from one remote monitoring center. The main idea is, however, still deriving the visibility or presence of fog by an operator judging the scenery and the presence of landmarks. Visibility sensors are also used, but they are rather costly and require regular maintenance. Moreover, observers, and in particular sensors, give only visibility information that is representative for a limited area. Hence the current density of visibility observations is insufficient to give detailed information on the presence of fog. Cameras are more and more deployed for surveillance and security reasons in cities and for monitoring traffic along main transportation ways. In addition to this primary use of cameras, we consider cameras as potential sensors to automatically identify low visibility conditions. The approach that we follow is to use machine learning techniques to determine the presence of fog and/or to make an estimation of the visibility. For that purpose a set of features are extracted from the camera images such as the number of edges, brightness, transmission of the image dark channel, fractal dimension. In addition to these image features, we also consider meteorological variables such as wind speed, temperature, relative humidity, and dew point as additional features to feed the machine learning model. The results obtained with a training and evaluation set consisting of 10-minute sampled images for two KNMI locations over a period of 1.5 years by using decision trees methods

  4. Making Ceramic Cameras

    Science.gov (United States)

    Squibb, Matt

    2009-01-01

    This article describes how to make a clay camera. This idea of creating functional cameras from clay allows students to experience ceramics, photography, and painting all in one unit. (Contains 1 resource and 3 online resources.)

  5. 78 FR 24199 - Streak Products, Inc. v. UTi, United States, Inc.; Notice of Filing of Complaint and Assignment

    Science.gov (United States)

    2013-04-24

    ... FEDERAL MARITIME COMMISSION [Docket No. 13--04] Streak Products, Inc. v. UTi, United States, Inc...,'' against UTi, United States, Inc. (``UTi''), hereinafter ``Respondent.'' Complainant states that it is a... therefore, has violated 46 U.S.C. 41104(2). Complainant also alleges that ``UTi engaged in an unfair or...

  6. Camera Movement in Narrative Cinema

    DEFF Research Database (Denmark)

    Nielsen, Jakob Isak

    2007-01-01

    section unearths what characterizes the literature on camera movement. The second section of the dissertation delineates the history of camera movement itself within narrative cinema. Several organizational principles subtending the on-screen effect of camera movement are revealed in section two...... but they are not organized into a coherent framework. This is the task that section three meets in proposing a functional taxonomy for camera movement in narrative cinema. Two presumptions subtend the taxonomy: That camera movement actively contributes to the way in which we understand the sound and images on the screen......, commentative or valuative manner. 4) Focalization: associating the movement of the camera with the viewpoints of characters or entities in the story world. 5) Reflexive: inviting spectators to engage with the artifice of camera movement. 6) Abstract: visualizing abstract ideas and concepts. In order...

  7. Meteor Film Recording with Digital Film Cameras with large CMOS Sensors

    Science.gov (United States)

    Slansky, P. C.

    2016-12-01

    In this article the author combines his professional know-how about cameras for film and television production with his amateur astronomy activities. Professional digital film cameras with high sensitivity are still quite rare in astronomy. One reason for this may be their costs of up to 20 000 and more (camera body only). In the interim, however,consumer photo cameras with film mode and very high sensitivity have come to the market for about 2 000 EUR. In addition, ultra-high sensitive professional film cameras, that are very interesting for meteor observation, have been introduced to the market. The particular benefits of digital film cameras with large CMOS sensors, including photo cameras with film recording function, for meteor recording are presented by three examples: a 2014 Camelopardalid, shot with a Canon EOS C 300, an exploding 2014 Aurigid, shot with a Sony alpha7S, and the 2016 Perseids, shot with a Canon ME20F-SH. All three cameras use large CMOS sensors; "large" meaning Super-35 mm, the classic 35 mm film format (24x13.5 mm, similar to APS-C size), or full format (36x24 mm), the classic 135 photo camera format. Comparisons are made to the widely used cameras with small CCD sensors, such as Mintron or Watec; "small" meaning 12" (6.4x4.8 mm) or less. Additionally, special photographic image processing of meteor film recordings is discussed.

  8. Neutron temporal diagnostic for high-yield deuterium–tritium cryogenic implosions on OMEGA

    Energy Technology Data Exchange (ETDEWEB)

    Stoeckl, C.; Boni, R.; Ehrne, F.; Forrest, C. J.; Glebov, V. Yu.; Katz, J.; Lonobile, D. J.; Magoon, J.; Regan, S. P.; Shoup, M. J.; Sorce, A.; Sorce, C.; Sangster, T. C.; Weiner, D. [Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, New York 14623-1299 (United States)

    2016-05-15

    A next-generation neutron temporal diagnostic (NTD) capable of recording high-quality data for the highest anticipated yield cryogenic deuterium–tritium (DT) implosion experiments was recently installed at the Omega Laser Facility. A high-quality measurement of the neutron production width is required to determine the hot-spot pressure achieved in inertial confinement fusion experiments—a key metric in assessing the quality of these implosions. The design of this NTD is based on a fast-rise-time plastic scintillator, which converts the neutron kinetic energy to 350- to 450-nm-wavelength light. The light from the scintillator inside the nose-cone assembly is relayed ∼16 m to a streak camera in a well-shielded location. An ∼200× reduction in neutron background was observed during the first high-yield DT cryogenic implosions compared to the current NTD installation on OMEGA. An impulse response of ∼40 ± 10 ps was measured in a dedicated experiment using hard x-rays from a planar target irradiated with a 10-ps short pulse from the OMEGA EP laser. The measured instrument response includes contributions from the scintillator rise time, optical relay, and streak camera.

  9. HEAVY ION FUSION SCIENCE VIRTUAL NATIONAL LABORATORY 2nd QUARTER 2010 MILESTONE REPORT. Develop the theory connecting pyrometer and streak camera spectrometer data to the material properties of beam heated targets and compare to the data

    International Nuclear Information System (INIS)

    More, R.M.; Barnard, J.J.; Bieniosek, F.M.; Henestroza, E.; Lidia, S.M.; Ni, P.A.

    2010-01-01

    This milestone has been accomplished. We have extended the theory that connects pyrometer and streak spectrometer data to material temperature on several fronts and have compared theory to NDCX-I experiments. For the case of NDCX-I, the data suggests that as the metallic foils are heated they break into droplets (cf. HIFS VNL Milestone Report FY 2009 Q4). Evaporation of the metallic surface will occur, but optical emission should be directly observable from the solid or liquid surface of the foil or from droplets. However, the emissivity of hot material may be changed from the cold material and interference effects will alter the spectrum emitted from small droplets. These effects have been incorporated into a theory of emission from droplets. We have measured emission using streaked spectrometry and together with theory of emission from heated droplets have inferred the temperature of a gold foil heated by the NDCX-I experiment. The intensity measured by the spectrometer is proportional to the emissivity times the blackbody intensity at the temperature of the foil or droplets. Traditionally, a functional form for the emissivity as a function of wavelength (such as a quadratic) is assumed and the three unknown emissivity parameters (for the case of a quadratic) and the temperature are obtained by minimizing the deviations from the fit. In the case of the NDCX-I experiment, two minima were obtained: at 7200 K and 2400 K. The best fit was at 7200 K. However, when the actual measured emissivity of gold was used and when the theoretical corrections for droplet interference effects were made for emission from droplets having radii in the range 0.2 to 2.0 microns, the corrected emissivity was consistent with the 2400 K value, whereas the fit emissivity at 7200 K shows no similarity to the corrected emissivity curves. Further, an estimate of the temperature obtained from beam heating is consistent with the lower value. This exercise proved to be a warning to be skeptical

  10. Developments of optical fast-gated imaging systems

    International Nuclear Information System (INIS)

    Koehler, H.A.; Kotecki, D.

    1984-08-01

    Several fast-gated imaging systems to measure ultra-fast single-transient data have been developed for time-resolved imaging of pulsed radiation sources. These systems were designed to achieve image recording times of 1 to 3 ms and dynamic ranges of >200:1 to produce large two-dimensional images (greater than or equal to 10 4 spatial points) of 1 to 2 ns exposure and small two-dimensional images (less than or equal to 200 spatial points) of less than or equal to 0.5 ns exposure. Both MCP intensified solid-state two-dimensional framing cameras and streak camera/solid-state camera systems were used; the framing camera system provides snap shots with high spatial resolution whereas the streak camera system provides for limited spatial points each with high temporal resolution. Applications of these systems include electron-beam, x-ray, gamma-ray, and neutron diagnostics. This report reviews the characteristics of the major components of fast-gated imaging systems developed at Lawrence Livermore National Laboratory. System performances are described in view of major experiments, and the diagnostic requirements of new experiments in atomic physics (x-ray lasers) and nuclear physics (fusion) are indicated

  11. Mixel camera--a new push-broom camera concept for high spatial resolution keystone-free hyperspectral imaging.

    Science.gov (United States)

    Høye, Gudrun; Fridman, Andrei

    2013-05-06

    Current high-resolution push-broom hyperspectral cameras introduce keystone errors to the captured data. Efforts to correct these errors in hardware severely limit the optical design, in particular with respect to light throughput and spatial resolution, while at the same time the residual keystone often remains large. The mixel camera solves this problem by combining a hardware component--an array of light mixing chambers--with a mathematical method that restores the hyperspectral data to its keystone-free form, based on the data that was recorded onto the sensor with large keystone. A Virtual Camera software, that was developed specifically for this purpose, was used to compare the performance of the mixel camera to traditional cameras that correct keystone in hardware. The mixel camera can collect at least four times more light than most current high-resolution hyperspectral cameras, and simulations have shown that the mixel camera will be photon-noise limited--even in bright light--with a significantly improved signal-to-noise ratio compared to traditional cameras. A prototype has been built and is being tested.

  12. Lessons Learned from Crime Caught on Camera

    DEFF Research Database (Denmark)

    Lindegaard, Marie Rosenkrantz; Bernasco, Wim

    2018-01-01

    Objectives: The widespread use of camera surveillance in public places offers criminologists the opportunity to systematically and unobtrusively observe crime, their main subject matter. The purpose of this essay is to inform the reader of current developments in research on crimes caught on came...

  13. Neutron cameras for ITER

    International Nuclear Information System (INIS)

    Johnson, L.C.; Barnes, C.W.; Batistoni, P.

    1998-01-01

    Neutron cameras with horizontal and vertical views have been designed for ITER, based on systems used on JET and TFTR. The cameras consist of fan-shaped arrays of collimated flight tubes, with suitably chosen detectors situated outside the biological shield. The sight lines view the ITER plasma through slots in the shield blanket and penetrate the vacuum vessel, cryostat, and biological shield through stainless steel windows. This paper analyzes the expected performance of several neutron camera arrangements for ITER. In addition to the reference designs, the authors examine proposed compact cameras, in which neutron fluxes are inferred from 16 N decay gammas in dedicated flowing water loops, and conventional cameras with fewer sight lines and more limited fields of view than in the reference designs. It is shown that the spatial sampling provided by the reference designs is sufficient to satisfy target measurement requirements and that some reduction in field of view may be permissible. The accuracy of measurements with 16 N-based compact cameras is not yet established, and they fail to satisfy requirements for parameter range and time resolution by large margins

  14. Automatic inference of geometric camera parameters and intercamera topology in uncalibrated disjoint surveillance cameras

    NARCIS (Netherlands)

    Hollander, R.J.M. den; Bouma, H.; Baan, J.; Eendebak, P.T.; Rest, J.H.C. van

    2015-01-01

    Person tracking across non-overlapping cameras and other types of video analytics benefit from spatial calibration information that allows an estimation of the distance between cameras and a relation between pixel coordinates and world coordinates within a camera. In a large environment with many

  15. Radiometric calibration of digital cameras using neural networks

    Science.gov (United States)

    Grunwald, Michael; Laube, Pascal; Schall, Martin; Umlauf, Georg; Franz, Matthias O.

    2017-08-01

    Digital cameras are used in a large variety of scientific and industrial applications. For most applications, the acquired data should represent the real light intensity per pixel as accurately as possible. However, digital cameras are subject to physical, electronic and optical effects that lead to errors and noise in the raw image. Temperature- dependent dark current, read noise, optical vignetting or different sensitivities of individual pixels are examples of such effects. The purpose of radiometric calibration is to improve the quality of the resulting images by reducing the influence of the various types of errors on the measured data and thus improving the quality of the overall application. In this context, we present a specialized neural network architecture for radiometric calibration of digital cameras. Neural networks are used to learn a temperature- and exposure-dependent mapping from observed gray-scale values to true light intensities for each pixel. In contrast to classical at-fielding, neural networks have the potential to model nonlinear mappings which allows for accurately capturing the temperature dependence of the dark current and for modeling cameras with nonlinear sensitivities. Both scenarios are highly relevant in industrial applications. The experimental comparison of our network approach to classical at-fielding shows a consistently higher reconstruction quality, also for linear cameras. In addition, the calibration is faster than previous machine learning approaches based on Gaussian processes.

  16. Time-resolved x-ray spectra from laser-generated high-density plasmas

    Science.gov (United States)

    Andiel, U.; Eidmann, Klaus; Witte, Klaus-Juergen

    2001-04-01

    We focused frequency doubled ultra short laser pulses on solid C, F, Na and Al targets, K-shell emission was systematically investigated by time resolved spectroscopy using a sub-ps streak camera. A large number of laser shots can be accumulated when triggering the camera with an Auston switch system at very high temporal precision. The system provides an outstanding time resolution of 1.7ps accumulating thousands of laser shots. The time duration of the He-(alpha) K-shell resonance lines was observed in the range of (2-4)ps and shows a decrease with the atomic number. The experimental results are well reproduced by hydro code simulations post processed with an atomic kinetics code.

  17. Nuclear test experimental science

    International Nuclear Information System (INIS)

    Struble, G.L.; Middleton, C.; Bucciarelli, G.; Carter, J.; Cherniak, J.; Donohue, M.L.; Kirvel, R.D.; MacGregor, P.; Reid, S.

    1989-01-01

    This report discusses research being conducted at Lawrence Livermore Laboratory under the following topics: prompt diagnostics; experimental modeling, design, and analysis; detector development; streak-camera data systems; weapons supporting research

  18. Nuclear test experimental science

    Energy Technology Data Exchange (ETDEWEB)

    Struble, G.L.; Middleton, C.; Bucciarelli, G.; Carter, J.; Cherniak, J.; Donohue, M.L.; Kirvel, R.D.; MacGregor, P.; Reid, S. (eds.)

    1989-01-01

    This report discusses research being conducted at Lawrence Livermore Laboratory under the following topics: prompt diagnostics; experimental modeling, design, and analysis; detector development; streak-camera data systems; weapons supporting research.

  19. Evaluation of mobile phone camera benchmarking using objective camera speed and image quality metrics

    Science.gov (United States)

    Peltoketo, Veli-Tapani

    2014-11-01

    When a mobile phone camera is tested and benchmarked, the significance of image quality metrics is widely acknowledged. There are also existing methods to evaluate the camera speed. However, the speed or rapidity metrics of the mobile phone's camera system has not been used with the quality metrics even if the camera speed has become a more and more important camera performance feature. There are several tasks in this work. First, the most important image quality and speed-related metrics of a mobile phone's camera system are collected from the standards and papers and, also, novel speed metrics are identified. Second, combinations of the quality and speed metrics are validated using mobile phones on the market. The measurements are done toward application programming interface of different operating systems. Finally, the results are evaluated and conclusions are made. The paper defines a solution to combine different image quality and speed metrics to a single benchmarking score. A proposal of the combined benchmarking metric is evaluated using measurements of 25 mobile phone cameras on the market. The paper is a continuation of a previous benchmarking work expanded with visual noise measurement and updates of the latest mobile phone versions.

  20. The ECM moves during primitive streak formation--computation of ECM versus cellular motion.

    Directory of Open Access Journals (Sweden)

    Evan A Zamir

    2008-10-01

    Full Text Available Galileo described the concept of motion relativity--motion with respect to a reference frame--in 1632. He noted that a person below deck would be unable to discern whether the boat was moving. Embryologists, while recognizing that embryonic tissues undergo large-scale deformations, have failed to account for relative motion when analyzing cell motility data. A century of scientific articles has advanced the concept that embryonic cells move ("migrate" in an autonomous fashion such that, as time progresses, the cells and their progeny assemble an embryo. In sharp contrast, the motion of the surrounding extracellular matrix scaffold has been largely ignored/overlooked. We developed computational/optical methods that measure the extent embryonic cells move relative to the extracellular matrix. Our time-lapse data show that epiblastic cells largely move in concert with a sub-epiblastic extracellular matrix during stages 2 and 3 in primitive streak quail embryos. In other words, there is little cellular motion relative to the extracellular matrix scaffold--both components move together as a tissue. The extracellular matrix displacements exhibit bilateral vortical motion, convergence to the midline, and extension along the presumptive vertebral axis--all patterns previously attributed solely to cellular "migration." Our time-resolved data pose new challenges for understanding how extracellular chemical (morphogen gradients, widely hypothesized to guide cellular trajectories at early gastrulation stages, are maintained in this dynamic extracellular environment. We conclude that models describing primitive streak cellular guidance mechanisms must be able to account for sub-epiblastic extracellular matrix displacements.

  1. β-Catenin Regulates Primitive Streak Induction through Collaborative Interactions with SMAD2/SMAD3 and OCT4

    DEFF Research Database (Denmark)

    Funa, Nina Sofi Ayumi; Schachter, Karen; Lerdrup, Mads

    2015-01-01

    Canonical Wnt and Nodal signaling are both required for induction of the primitive streak (PS), which guides organization of the early embryo. The Wnt effector b-catenin is thought to function in these early lineage specification decisions via transcriptional activation of Nodal signaling. Here, we...... specification. This study provides mechanistic insight into how Wnt signaling controls early cell lineage decisions....

  2. Improving Situational Awareness in camera surveillance by combining top-view maps with camera images

    NARCIS (Netherlands)

    Kooi, F.L.; Zeeders, R.

    2009-01-01

    The goal of the experiment described is to improve today's camera surveillance in public spaces. Three designs with the camera images combined on a top-view map were compared to each other and to the current situation in camera surveillance. The goal was to test which design makes spatial

  3. Realistic camera noise modeling with application to improved HDR synthesis

    Science.gov (United States)

    Goossens, Bart; Luong, Hiêp; Aelterman, Jan; Pižurica, Aleksandra; Philips, Wilfried

    2012-12-01

    Due to the ongoing miniaturization of digital camera sensors and the steady increase of the "number of megapixels", individual sensor elements of the camera become more sensitive to noise, even deteriorating the final image quality. To go around this problem, sophisticated processing algorithms in the devices, can help to maximally exploit the knowledge on the sensor characteristics (e.g., in terms of noise), and offer a better image reconstruction. Although a lot of research focuses on rather simplistic noise models, such as stationary additive white Gaussian noise, only limited attention has gone to more realistic digital camera noise models. In this article, we first present a digital camera noise model that takes several processing steps in the camera into account, such as sensor signal amplification, clipping, post-processing,.. We then apply this noise model to the reconstruction problem of high dynamic range (HDR) images from a small set of low dynamic range (LDR) exposures of a static scene. In literature, HDR reconstruction is mostly performed by computing a weighted average, in which the weights are directly related to the observer pixel intensities of the LDR image. In this work, we derive a Bayesian probabilistic formulation of a weighting function that is near-optimal in the MSE sense (or SNR sense) of the reconstructed HDR image, by assuming exponentially distributed irradiance values. We define the weighting function as the probability that the observed pixel intensity is approximately unbiased. The weighting function can be directly computed based on the noise model parameters, which gives rise to different symmetric and asymmetric shapes when electronic noise or photon noise is dominant. We also explain how to deal with the case that some of the noise model parameters are unknown and explain how the camera response function can be estimated using the presented noise model. Finally, experimental results are provided to support our findings.

  4. Camera Trajectory fromWide Baseline Images

    Science.gov (United States)

    Havlena, M.; Torii, A.; Pajdla, T.

    2008-09-01

    suggested in to draw 5-tuples from the list of tentative matches ordered ascendingly by the distance of their descriptors which may help to reduce the number of samples in RANSAC. From each 5-tuple, relative orientation is computed by solving the 5-point minimal relative orientation problem for calibrated cameras. Often, there are more models which are supported by a large number of matches. Thus the chance that the correct model, even if it has the largest support, will be found by running a single RANSAC is small. Work suggested to generate models by randomized sampling as in RANSAC but to use soft (kernel) voting for a parameter instead of looking for the maximal support. The best model is then selected as the one with the parameter closest to the maximum in the accumulator space. In our case, we vote in a two-dimensional accumulator for the estimated camera motion direction. However, unlike in, we do not cast votes directly by each sampled epipolar geometry but by the best epipolar geometries recovered by ordered sampling of RANSAC. With our technique, we could go up to the 98.5 % contamination of mismatches with comparable effort as simple RANSAC does for the contamination by 84 %. The relative camera orientation with the motion direction closest to the maximum in the voting space is finally selected. As already mentioned in the first paragraph, the use of camera trajectory estimates is quite wide. In we have introduced a technique for measuring the size of camera translation relatively to the observed scene which uses the dominant apical angle computed at the reconstructed scene points and is robust against mismatches. The experiments demonstrated that the measure can be used to improve the robustness of camera path computation and object recognition for methods which use a geometric, e.g. the ground plane, constraint such as does for the detection of pedestrians. Using the camera trajectories, perspective cutouts with stabilized horizon are constructed and an

  5. A fast, noniterative approach for accelerated high-temporal resolution cine-CMR using dynamically interleaved streak removal in the power-spectral encoded domain with low-pass filtering (DISPEL) and modulo-prime spokes (MoPS).

    Science.gov (United States)

    Kawaji, Keigo; Patel, Mita B; Cantrell, Charles G; Tanaka, Akiko; Marino, Marco; Tamura, Satoshi; Wang, Hui; Wang, Yi; Carroll, Timothy J; Ota, Takeyoshi; Patel, Amit R

    2017-07-01

    To introduce a pair of accelerated non-Cartesian acquisition principles that when combined, exploit the periodicity of k-space acquisition, and thereby enable acquisition of high-temporal cine Cardiac Magnetic Resonance (CMR). The mathematical formulation of a noniterative, undersampled non-Cartesian cine acquisition and reconstruction is presented. First, a low-pass filtering step that exploits streaking artifact redundancy is provided (i.e., Dynamically Interleaved Streak removal in the Power-spectrum Encoded domain with Low-pass filtering [DISPEL]). Next, an effective radial acquisition for the DISPEL approach that exploits the property of prime numbers is described (i.e., Modulo-Prime Spoke [MoPS]). Both DISPEL and MoPS are examined using numerical simulation of a digital heart phantom to show that high-temporal cine-CMR is feasible without removing physiologic motion vs aperiodic interleaving using Golden Angles. The combined high-temporal cine approach is next examined in 11 healthy subjects for a time-volume curve assessment of left ventricular systolic and diastolic performance vs conventional Cartesian cine-CMR reference. The DISPEL method was first shown using simulation under different streak cycles to allow separation of undersampled radial streaking artifacts from physiologic motion with a sufficiently frequent streak-cycle interval. Radial interleaving with MoPS is next shown to allow interleaves with pseudo-Golden-Angle variants, and be more compatible with DISPEL against irrational and nonperiodic rotation angles, including the Golden-Angle-derived rotations. In the in vivo data, the proposed method showed no statistical difference in the systolic performance, while diastolic parameters sensitive to the cine's temporal resolution were statistically significant (P cine). We demonstrate a high-temporal resolution cine-CMR using DISPEL and MoPS, whose streaking artifact was separated from physiologic motion. © 2017 American Association of Physicists

  6. Advanced CCD camera developments

    Energy Technology Data Exchange (ETDEWEB)

    Condor, A. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    Two charge coupled device (CCD) camera systems are introduced and discussed, describing briefly the hardware involved, and the data obtained in their various applications. The Advanced Development Group Defense Sciences Engineering Division has been actively designing, manufacturing, fielding state-of-the-art CCD camera systems for over a decade. These systems were originally developed for the nuclear test program to record data from underground nuclear tests. Today, new and interesting application for these systems have surfaced and development is continuing in the area of advanced CCD camera systems, with the new CCD camera that will allow experimenters to replace film for x-ray imaging at the JANUS, USP, and NOVA laser facilities.

  7. A solid state lightning propagation speed sensor

    Science.gov (United States)

    Mach, Douglas M.; Rust, W. David

    1989-01-01

    A device to measure the propagation speeds of cloud-to-ground lightning has been developed. The lightning propagation speed (LPS) device consists of eight solid state silicon photodetectors mounted behind precision horizontal slits in the focal plane of a 50-mm lens on a 35-mm camera. Although the LPS device produces results similar to those obtained from a streaking camera, the LPS device has the advantages of smaller size, lower cost, mobile use, and easier data collection and analysis. The maximum accuracy for the LPS is 0.2 microsec, compared with about 0.8 microsecs for the streaking camera. It is found that the return stroke propagation speed for triggered lightning is different than that for natural lightning if measurements are taken over channel segments less than 500 m. It is suggested that there are no significant differences between the propagation speeds of positive and negative flashes. Also, differences between natural and triggered dart leaders are discussed.

  8. The upgrade of the H.E.S.S. cameras

    Science.gov (United States)

    Giavitto, Gianluca; Ashton, Terry; Balzer, Arnim; Berge, David; Brun, Francois; Chaminade, Thomas; Delagnes, Eric; Fontaine, Gerard; Füßling, Matthias; Giebels, Berrie; Glicenstein, Jean-Francois; Gräber, Tobias; Hinton, Jim; Jahnke, Albert; Klepser, Stefan; Kossatz, Marko; Kretzschmann, Axel; Lefranc, Valentin; Leich, Holger; Lüdecke, Hartmut; Lypova, Iryna; Manigot, Pascal; Marandon, Vincent; Moulin, Emmanuel; Naurois, Mathieu de; Nayman, Patrick; Ohm, Stefan; Penno, Marek; Ross, Duncan; Salek, David; Schade, Markus; Schwab, Thomas; Simoni, Rachel; Stegmann, Christian; Steppa, Constantin; Thornhill, Julian; Toussnel, Francois

    2017-12-01

    The High Energy Stereoscopic System (HESS) is an array of imaging atmospheric Cherenkov telescopes (IACTs) located in the Khomas highland in Namibia. It was built to detect Very High Energy (VHE > 100 GeV) cosmic gamma rays. Since 2003, HESS has discovered the majority of the known astrophysical VHE gamma-ray sources, opening a new observational window on the extreme non-thermal processes at work in our universe. HESS consists of four 12-m diameter Cherenkov telescopes (CT1-4), which started data taking in 2002, and a larger 28-m telescope (CT5), built in 2012, which lowers the energy threshold of the array to 30 GeV . The cameras of CT1-4 are currently undergoing an extensive upgrade, with the goals of reducing their failure rate, reducing their readout dead time and improving the overall performance of the array. The entire camera electronics has been renewed from ground-up, as well as the power, ventilation and pneumatics systems, and the control and data acquisition software. Only the PMTs and their HV supplies have been kept from the original cameras. Novel technical solutions have been introduced, which will find their way into some of the Cherenkov cameras foreseen for the next-generation Cherenkov Telescope Array (CTA) observatory. In particular, the camera readout system is the first large-scale system based on the analog memory chip NECTAr, which was designed for CTA cameras. The camera control subsystems and the control software framework also pursue an innovative design, exploiting cutting-edge hardware and software solutions which excel in performance, robustness and flexibility. The CT1 camera has been upgraded in July 2015 and is currently taking data; CT2-4 have been upgraded in fall 2016. Together they will assure continuous operation of HESS at its full sensitivity until and possibly beyond the advent of CTA. This contribution describes the design, the testing and the in-lab and on-site performance of all components of the newly upgraded HESS

  9. Solid state video cameras

    CERN Document Server

    Cristol, Y

    2013-01-01

    Solid State Video Cameras reviews the state of the art in the field of solid-state television cameras as compiled from patent literature. Organized into 10 chapters, the book begins with the basic array types of solid-state imagers and appropriate read-out circuits and methods. Documents relating to improvement of picture quality, such as spurious signal suppression, uniformity correction, or resolution enhancement, are also cited. The last part considerssolid-state color cameras.

  10. Multiple Sensor Camera for Enhanced Video Capturing

    Science.gov (United States)

    Nagahara, Hajime; Kanki, Yoshinori; Iwai, Yoshio; Yachida, Masahiko

    A resolution of camera has been drastically improved under a current request for high-quality digital images. For example, digital still camera has several mega pixels. Although a video camera has the higher frame-rate, the resolution of a video camera is lower than that of still camera. Thus, the high-resolution is incompatible with the high frame rate of ordinary cameras in market. It is difficult to solve this problem by a single sensor, since it comes from physical limitation of the pixel transfer rate. In this paper, we propose a multi-sensor camera for capturing a resolution and frame-rate enhanced video. Common multi-CCDs camera, such as 3CCD color camera, has same CCD for capturing different spectral information. Our approach is to use different spatio-temporal resolution sensors in a single camera cabinet for capturing higher resolution and frame-rate information separately. We build a prototype camera which can capture high-resolution (2588×1958 pixels, 3.75 fps) and high frame-rate (500×500, 90 fps) videos. We also proposed the calibration method for the camera. As one of the application of the camera, we demonstrate an enhanced video (2128×1952 pixels, 90 fps) generated from the captured videos for showing the utility of the camera.

  11. Using DSLR cameras in digital holography

    Science.gov (United States)

    Hincapié-Zuluaga, Diego; Herrera-Ramírez, Jorge; García-Sucerquia, Jorge

    2017-08-01

    In Digital Holography (DH), the size of the bidimensional image sensor to record the digital hologram, plays a key role on the performance of this imaging technique; the larger the size of the camera sensor, the better the quality of the final reconstructed image. Scientific cameras with large formats are offered in the market, but their cost and availability limit their use as a first option when implementing DH. Nowadays, DSLR cameras provide an easy-access alternative that is worthwhile to be explored. The DSLR cameras are a wide, commercial, and available option that in comparison with traditional scientific cameras, offer a much lower cost per effective pixel over a large sensing area. However, in the DSLR cameras, with their RGB pixel distribution, the sampling of information is different to the sampling in monochrome cameras usually employed in DH. This fact has implications in their performance. In this work, we discuss why DSLR cameras are not extensively used for DH, taking into account the problem reported by different authors of object replication. Simulations of DH using monochromatic and DSLR cameras are presented and a theoretical deduction for the replication problem using the Fourier theory is also shown. Experimental results of DH implementation using a DSLR camera show the replication problem.

  12. World's fastest and most sensitive astronomical camera

    Science.gov (United States)

    2009-06-01

    The next generation of instruments for ground-based telescopes took a leap forward with the development of a new ultra-fast camera that can take 1500 finely exposed images per second even when observing extremely faint objects. The first 240x240 pixel images with the world's fastest high precision faint light camera were obtained through a collaborative effort between ESO and three French laboratories from the French Centre National de la Recherche Scientifique/Institut National des Sciences de l'Univers (CNRS/INSU). Cameras such as this are key components of the next generation of adaptive optics instruments of Europe's ground-based astronomy flagship facility, the ESO Very Large Telescope (VLT). ESO PR Photo 22a/09 The CCD220 detector ESO PR Photo 22b/09 The OCam camera ESO PR Video 22a/09 OCam images "The performance of this breakthrough camera is without an equivalent anywhere in the world. The camera will enable great leaps forward in many areas of the study of the Universe," says Norbert Hubin, head of the Adaptive Optics department at ESO. OCam will be part of the second-generation VLT instrument SPHERE. To be installed in 2011, SPHERE will take images of giant exoplanets orbiting nearby stars. A fast camera such as this is needed as an essential component for the modern adaptive optics instruments used on the largest ground-based telescopes. Telescopes on the ground suffer from the blurring effect induced by atmospheric turbulence. This turbulence causes the stars to twinkle in a way that delights poets, but frustrates astronomers, since it blurs the finest details of the images. Adaptive optics techniques overcome this major drawback, so that ground-based telescopes can produce images that are as sharp as if taken from space. Adaptive optics is based on real-time corrections computed from images obtained by a special camera working at very high speeds. Nowadays, this means many hundreds of times each second. The new generation instruments require these

  13. Selecting a digital camera for telemedicine.

    Science.gov (United States)

    Patricoski, Chris; Ferguson, A Stewart

    2009-06-01

    The digital camera is an essential component of store-and-forward telemedicine (electronic consultation). There are numerous makes and models of digital cameras on the market, and selecting a suitable consumer-grade camera can be complicated. Evaluation of digital cameras includes investigating the features and analyzing image quality. Important features include the camera settings, ease of use, macro capabilities, method of image transfer, and power recharging. Consideration needs to be given to image quality, especially as it relates to color (skin tones) and detail. It is important to know the level of the photographer and the intended application. The goal is to match the characteristics of the camera with the telemedicine program requirements. In the end, selecting a digital camera is a combination of qualitative (subjective) and quantitative (objective) analysis. For the telemedicine program in Alaska in 2008, the camera evaluation and decision process resulted in a specific selection based on the criteria developed for our environment.

  14. Time-resolved interaction investigations of carbocyanine dyes and chlorophyll a in solution

    International Nuclear Information System (INIS)

    Feller, K.H.; Fassler, D.

    1983-01-01

    Using a Nd:YAG laser/streak camera system of 30 ps time resolution the quenching of the fluorescence of the carbocyanine dye ICC by chlorophyll a in methanolic solution was investigated. The fluorescence lifetime of ICC decreased within the chlorophyll concentration range 0 - 9x10 - 5 mol/l from 170 ps to 135 ps. The observed very effective fluorescence quenching process suggests that the formation of heteroaggregates from ICC and chlorophyll is responsible for the rapid energy transfer. (author)

  15. Binding constants of Southern rice black-streaked dwarf virus Coat Protein with ferulic acid derivatives

    Directory of Open Access Journals (Sweden)

    Longlu Ran

    2018-04-01

    Full Text Available The data present binding constants between ferulic acid derivatives and the Coat Protein (P10 by fluorescence titration in this article, which is hosted in the research article entitled “Interaction Research on an Antiviral Molecule that Targets the Coat Protein of Southern rice black-streaked dwarf virus’’ (Ran et al., 2017 [1]. The data include fluorescence quenching spectrum, Stern–Volmer quenching constants, and binding parameters. In this article, a more comprehensive data interpretation and analysis is explained.

  16. Adaptation Computing Parameters of Pan-Tilt-Zoom Cameras for Traffic Monitoring

    Directory of Open Access Journals (Sweden)

    Ya Lin WU

    2014-01-01

    Full Text Available The Closed- CIRCUIT television (CCTV cameras have been widely used in recent years for traffic monitoring and surveillance applications. We can use CCTV cameras to extract automatically real-time traffic parameters according to the image processing and tracking technologies. Especially, the pan-tilt-zoom (PTZ cameras can provide flexible view selection as well as a wider observation range, and this makes the traffic parameters can be accurately calculated. Therefore, that the parameters of PTZ cameras are calibrated plays an important role in vision-based traffic applications. However, in the specific traffic environment, which is that the license plate number of the illegal parking is located, the parameters of PTZ cameras have to be updated according to the position and distance of illegal parking. In proposed traffic monitoring systems, we use the ordinary webcam and PTZ camera. We get vanishing-point of traffic lane lines in the pixel-based coordinate system by fixed webcam. The parameters of PTZ camera can be initialized by distance of the traffic monitoring and specific objectives and vanishing-point. And then we can use the coordinate position of the illegally parked car to update the parameters of PTZ camera and then get the real word coordinate position of the illegally parked car and use it to compute the distance. The result shows the error of the tested distance and real distance is only 0.2064 meter.

  17. The REM Observing Software

    Directory of Open Access Journals (Sweden)

    Mauro Stefanon

    2010-01-01

    Together they grant the system safety, automatically schedule and perform observations with two simultaneous cameras of user-defined targets, and drive fast reaction to satellite alerts. Subsequent data reduction is left to pipelines managed by each camera.

  18. A mathematical model for camera calibration based on straight lines

    Directory of Open Access Journals (Sweden)

    Antonio M. G. Tommaselli

    2005-12-01

    Full Text Available In other to facilitate the automation of camera calibration process, a mathematical model using straight lines was developed, which is based on the equivalent planes mathematical model. Parameter estimation of the developed model is achieved by the Least Squares Method with Conditions and Observations. The same method of adjustment was used to implement camera calibration with bundles, which is based on points. Experiments using simulated and real data have shown that the developed model based on straight lines gives results comparable to the conventional method with points. Details concerning the mathematical development of the model and experiments with simulated and real data will be presented and the results with both methods of camera calibration, with straight lines and with points, will be compared.

  19. Distributing functionality in the Drift Scan Camera System

    International Nuclear Information System (INIS)

    Nicinski, T.; Constanta-Fanourakis, P.; MacKinnon, B.; Petravick, D.; Pluquet, C.; Rechenmacher, R.; Sergey, G.

    1993-11-01

    The Drift Scan Camera (DSC) System acquires image data from a CCD camera. The DSC is divided physically into two subsystems which are tightly coupled to each other. Functionality is split between these two subsystems: the front-end performs data acquisition while the host subsystem performs near real-time data analysis and control. Yet, through the use of backplane-based Remote Procedure Calls, the feel of one coherent system is preserved. Observers can control data acquisition, archiving to tape, and other functions from the host, but, the front-end can accept these same commands and operate independently. The DSC meets the needs for such robustness and cost-effective computing

  20. Automatic locking radioisotope camera lock

    International Nuclear Information System (INIS)

    Rosauer, P.J.

    1978-01-01

    The lock of the present invention secures the isotope source in a stored shielded condition in the camera until a positive effort has been made to open the lock and take the source outside of the camera and prevents disconnection of the source pigtail unless the source is locked in a shielded condition in the camera. It also gives a visual indication of the locked or possible exposed condition of the isotope source and prevents the source pigtail from being completely pushed out of the camera, even when the lock is released. (author)

  1. Web Camera Based Eye Tracking to Assess Visual Memory on a Visual Paired Comparison Task

    Directory of Open Access Journals (Sweden)

    Nicholas T. Bott

    2017-06-01

    Full Text Available Background: Web cameras are increasingly part of the standard hardware of most smart devices. Eye movements can often provide a noninvasive “window on the brain,” and the recording of eye movements using web cameras is a burgeoning area of research.Objective: This study investigated a novel methodology for administering a visual paired comparison (VPC decisional task using a web camera.To further assess this method, we examined the correlation between a standard eye-tracking camera automated scoring procedure [obtaining images at 60 frames per second (FPS] and a manually scored procedure using a built-in laptop web camera (obtaining images at 3 FPS.Methods: This was an observational study of 54 clinically normal older adults.Subjects completed three in-clinic visits with simultaneous recording of eye movements on a VPC decision task by a standard eye tracker camera and a built-in laptop-based web camera. Inter-rater reliability was analyzed using Siegel and Castellan's kappa formula. Pearson correlations were used to investigate the correlation between VPC performance using a standard eye tracker camera and a built-in web camera.Results: Strong associations were observed on VPC mean novelty preference score between the 60 FPS eye tracker and 3 FPS built-in web camera at each of the three visits (r = 0.88–0.92. Inter-rater agreement of web camera scoring at each time point was high (κ = 0.81–0.88. There were strong relationships on VPC mean novelty preference score between 10, 5, and 3 FPS training sets (r = 0.88–0.94. Significantly fewer data quality issues were encountered using the built-in web camera.Conclusions: Human scoring of a VPC decisional task using a built-in laptop web camera correlated strongly with automated scoring of the same task using a standard high frame rate eye tracker camera.While this method is not suitable for eye tracking paradigms requiring the collection and analysis of fine-grained metrics, such as

  2. Acceptance/Operational Test Report for Tank 241-AN-104 camera and camera purge control system

    International Nuclear Information System (INIS)

    Castleberry, J.L.

    1995-11-01

    This Acceptance/Operational Test Procedure (ATP/OTP) will document the satisfactory operation of the camera purge panel, purge control panel, color camera system and associated control components destined for installation. The final acceptance of the complete system will be performed in the field. The purge panel and purge control panel will be tested for its safety interlock which shuts down the camera and pan-and-tilt inside the tank vapor space during loss of purge pressure and that the correct purge volume exchanges are performed as required by NFPA 496. This procedure is separated into seven sections. This Acceptance/Operational Test Report documents the successful acceptance and operability testing of the 241-AN-104 camera system and camera purge control system

  3. Payload topography camera of Chang'e-3

    International Nuclear Information System (INIS)

    Yu, Guo-Bin; Liu, En-Hai; Zhao, Ru-Jin; Zhong, Jie; Zhou, Xiang-Dong; Zhou, Wu-Lin; Wang, Jin; Chen, Yuan-Pei; Hao, Yong-Jie

    2015-01-01

    Chang'e-3 was China's first soft-landing lunar probe that achieved a successful roving exploration on the Moon. A topography camera functioning as the lander's “eye” was one of the main scientific payloads installed on the lander. It was composed of a camera probe, an electronic component that performed image compression, and a cable assembly. Its exploration mission was to obtain optical images of the lunar topography in the landing zone for investigation and research. It also observed rover movement on the lunar surface and finished taking pictures of the lander and rover. After starting up successfully, the topography camera obtained static images and video of rover movement from different directions, 360° panoramic pictures of the lunar surface around the lander from multiple angles, and numerous pictures of the Earth. All images of the rover, lunar surface, and the Earth were clear, and those of the Chinese national flag were recorded in true color. This paper describes the exploration mission, system design, working principle, quality assessment of image compression, and color correction of the topography camera. Finally, test results from the lunar surface are provided to serve as a reference for scientific data processing and application. (paper)

  4. Direct observation of mass oscillations due to ablative Richtmyer-Meshkov instability and feedout in planar plastic targets

    International Nuclear Information System (INIS)

    Aglitskiy, Y.; Velikovich, A.L.; Karasik, M.; Serlin, V.; Pawley, C.J.; Schmitt, A.J.; Obenschain, S.P.; Mostovych, A.N.; Gardner, J.H.; Metzler, N.

    2002-01-01

    Perturbations that seed Rayleigh-Taylor (RT) instability in laser-driven targets form during the early-time period. This time includes a shock wave transit from the front to the rear surface of the target, and a rarefaction wave transit in the opposite direction. During this time interval, areal mass perturbations caused by all sources of nonuniformity (laser imprint, surface ripple) are expected to oscillate. The first direct experimental observations of the areal mass oscillations due to ablative Richtmyer-Meshkov (RM) instability and feedout followed by the RT growth of areal mass modulation are discussed. The experiments were made with 40-99 μm thick planar plastic targets rippled either on the front or on the rear with a sine wave ripple with either 30 or 45 μm wavelength and with 0.5, 1, or 1.5 μm amplitude. Targets were irradiated with 4 ns long Nike KrF laser pulses at ∼50 TW/cm2. The oscillations were observed with our novel diagnostic technique, a monochromatic x-ray imager coupled to a streak camera. For the ablative RM instability (front side ripple), the mass modulation amplitude was typically observed to grow, reach a peak, and then decrease, after which the exponential RT growth started. In some cases, one phase reversal due to the ablative RM instability was observed. For the feedout geometry (rear side ripple), in all cases two phase reversals were observed: a distinct half-oscillation was followed by the onset of the RT growth, resulting in a second phase reversal

  5. Development of high-speed video cameras

    Science.gov (United States)

    Etoh, Takeharu G.; Takehara, Kohsei; Okinaka, Tomoo; Takano, Yasuhide; Ruckelshausen, Arno; Poggemann, Dirk

    2001-04-01

    Presented in this paper is an outline of the R and D activities on high-speed video cameras, which have been done in Kinki University since more than ten years ago, and are currently proceeded as an international cooperative project with University of Applied Sciences Osnabruck and other organizations. Extensive marketing researches have been done, (1) on user's requirements on high-speed multi-framing and video cameras by questionnaires and hearings, and (2) on current availability of the cameras of this sort by search of journals and websites. Both of them support necessity of development of a high-speed video camera of more than 1 million fps. A video camera of 4,500 fps with parallel readout was developed in 1991. A video camera with triple sensors was developed in 1996. The sensor is the same one as developed for the previous camera. The frame rate is 50 million fps for triple-framing and 4,500 fps for triple-light-wave framing, including color image capturing. Idea on a video camera of 1 million fps with an ISIS, In-situ Storage Image Sensor, was proposed in 1993 at first, and has been continuously improved. A test sensor was developed in early 2000, and successfully captured images at 62,500 fps. Currently, design of a prototype ISIS is going on, and, hopefully, will be fabricated in near future. Epoch-making cameras in history of development of high-speed video cameras by other persons are also briefly reviewed.

  6. Analysis of the three-dimensional trajectories of dusts observed with a stereoscopic fast framing camera in the Large Helical Device

    Energy Technology Data Exchange (ETDEWEB)

    Shoji, M., E-mail: shoji@LHD.nifs.ac.jp [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5292, Gifu (Japan); Masuzaki, S. [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5292, Gifu (Japan); Tanaka, Y. [Kanazawa University, Kakuma, Kanazawa 920-1192 (Japan); Pigarov, A.Yu.; Smirnov, R.D. [University of California at San Diego, La Jolla, CA 92093 (United States); Kawamura, G.; Uesugi, Y.; Yamada, H. [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5292, Gifu (Japan)

    2015-08-15

    The three-dimensional trajectories of dusts have been observed with two stereoscopic fast framing cameras installed in upper and outer viewports in the Large Helical Device (LHD). It shows that the dust trajectories locate in divertor legs and an ergodic layer around the main plasma confinement region. While it is found that most of the dusts approximately move along the magnetic field lines with acceleration, there are some dusts which have sharply curved trajectories crossing over the magnetic field lines. A dust transport simulation code was modified to investigate the dust trajectories in fully three dimensional geometries such as LHD plasmas. It can explain the general trend of most of observed dust trajectories by the effect of the plasma flow in the peripheral plasma. However, the behavior of the some dusts with sharply curved trajectories is not consistent with the simulations.

  7. Study on Laser Induced Plasma Produced in Liquid

    International Nuclear Information System (INIS)

    Tsuda, N.; Yamada, J.

    2003-01-01

    When an intense laser light is focused in liquid, a hot plasma is produced at the focal spot. The breakdown threshold and the transmittance of sodium choroids solution are observed using excimer laser or YAG laser. The breakdown threshold decreases with increasing NaCl concentration. Threshold intensity of plasma produced by YAG laser is lower than excimer laser. The behavior of plasma development is observed by a streak camera. The plasma produced by a YAG laser develops only backward. However, the plasma produced by excimer laser develops not only backward but also forward same as the plasma development in high-pressure gases

  8. An Optical and Terahertz Instrumentation System at the FAST LINAC at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Thurman-Keup, R. [Fermilab; Lumpkin, A. H. [Fermilab; Thangaraj, J. [Fermilab

    2017-08-01

    FAST is a facility at Fermilab that consists of a photoinjector, two superconducting capture cavities, one superconducting ILC-style cryomodule, and a small ring for studying non-linear, integrable beam optics called IOTA. This paper discusses the layout for the optical transport system that provides optical radiation to an externally located streak camera for bunch length measurements, and THz radiation to a Martin-Puplett interferometer, also for bunch length measurements. It accepts radiation from two synchrotron radiation ports in a chicane bunch compressor and a diffraction/transition radiation screen downstream of the compressor. It also has the potential to access signal from a transition radiation screen or YAG screen after the spectrometer magnet for measurements of energy-time correlations. Initial results from both the streak camera and Martin-Puplett will be presented.

  9. Relationship between the shoot characteristics and plant resistance to vascular-streak dieback on cocoa

    Directory of Open Access Journals (Sweden)

    Agung Wahyu Soesilo

    2014-12-01

    Full Text Available Vascular-streak dieback (Oncobasidium theobromae is a serious disease on cocoa damaging the vegetative tissue especially on the branches and leaves. This research was aimed to identify the relationship between characteristics of sprouting ability and VSD resistance to confirm the response of cocoa to pruning treatment on VSD control and developing criteria for selection. Trial was carried out at Kaliwining Experimental Station of ICCRI, a VSD-endemic area by using 668 plants of hybrid populayion which were derivated from intercrossing among seven clones performing different response to VSD. The resistance was evaluated by scoring the plant damage with the scale of 0-6 on drought season in the year of 2009 and 2011. The characteristics of sprouting ability was assessed by recording the pruned trees for the variables of the number of re-growth shoot, shoot height, number of new shoot per pruned branches, shoot diameter and number of leaves per shoot. It was analyzed that the variables of the number of shoot per pruned branches, shoot diameter, shoot height and number of leaves per shoot were not significantly correlated to the score of VSD damage. Grouping of the resistance also performed similar results whereas mean of the sprouting variables were not different among group but the percentage of sprouted branches tend to be higher with the higher of the resistance (lower score. This result confirmed any mechanism of tolerance on VSD resistance by accelerating shoot rejuvenation on resistant plant. Key words : vascular-streak diaback, cocoa, resistance, characteristics of sprouting

  10. Video camera use at nuclear power plants

    International Nuclear Information System (INIS)

    Estabrook, M.L.; Langan, M.O.; Owen, D.E.

    1990-08-01

    A survey of US nuclear power plants was conducted to evaluate video camera use in plant operations, and determine equipment used and the benefits realized. Basic closed circuit television camera (CCTV) systems are described and video camera operation principles are reviewed. Plant approaches for implementing video camera use are discussed, as are equipment selection issues such as setting task objectives, radiation effects on cameras, and the use of disposal cameras. Specific plant applications are presented and the video equipment used is described. The benefits of video camera use --- mainly reduced radiation exposure and increased productivity --- are discussed and quantified. 15 refs., 6 figs

  11. The cloud monitor by an infrared camera at the Telescope Array experiment

    International Nuclear Information System (INIS)

    Shibata, F.

    2011-01-01

    The mesurement of the extensive air shower using the fluorescence detectors (FDs) is affected by the condition of the atmosphere. In particular, FD aperture is limited by cloudiness. If cloud exists on the light path from extensive air shower to FDs, fluorescence photons will be absorbed drastically. Therefore cloudiness of FD's field of view (FOV) is one of important quality cut condition in FD analysis. In the Telescope Array (TA), an infrared (IR) camera with 320x236 pixels and a filed of view of 25.8 deg. x19.5 deg. has been installed at an observation site for cloud monitoring during FD observations. This IR camera measures temperature of the sky every 30 min during FD observation. IR camera is mounted on steering table, which can be changed in elevation and azimuthal direction. Clouds can be seen at a higher temperature than areas of cloudless sky from these temperature maps. In this paper, we discuss the quality of the cloud monitoring data, the analysis method, and current quality cut condition of cloudiness in FD analysis.

  12. The development of large-aperture test system of infrared camera and visible CCD camera

    Science.gov (United States)

    Li, Yingwen; Geng, Anbing; Wang, Bo; Wang, Haitao; Wu, Yanying

    2015-10-01

    Infrared camera and CCD camera dual-band imaging system is used in many equipment and application widely. If it is tested using the traditional infrared camera test system and visible CCD test system, 2 times of installation and alignment are needed in the test procedure. The large-aperture test system of infrared camera and visible CCD camera uses the common large-aperture reflection collimator, target wheel, frame-grabber, computer which reduces the cost and the time of installation and alignment. Multiple-frame averaging algorithm is used to reduce the influence of random noise. Athermal optical design is adopted to reduce the change of focal length location change of collimator when the environmental temperature is changing, and the image quality of the collimator of large field of view and test accuracy are also improved. Its performance is the same as that of the exotic congener and is much cheaper. It will have a good market.

  13. Use of camera drive in stereoscopic display of learning contents of introductory physics

    Science.gov (United States)

    Matsuura, Shu

    2011-03-01

    Simple 3D physics simulations with stereoscopic display were created for a part of introductory physics e-Learning. First, cameras to see the 3D world can be made controllable by the user. This enabled to observe the system and motions of objects from any position in the 3D world. Second, cameras were made attachable to one of the moving object in the simulation so as to observe the relative motion of other objects. By this option, it was found that users perceive the velocity and acceleration more sensibly on stereoscopic display than on non-stereoscopic 3D display. Simulations were made using Adobe Flash ActionScript, and Papervison 3D library was used to render the 3D models in the flash web pages. To display the stereogram, two viewports from virtual cameras were displayed in parallel in the same web page. For observation of stereogram, the images of two viewports were superimposed by using 3D stereogram projection box (T&TS CO., LTD.), and projected on an 80-inch screen. The virtual cameras were controlled by keyboard and also by Nintendo Wii remote controller buttons. In conclusion, stereoscopic display offers learners more opportunities to play with the simulated models, and to perceive the characteristics of motion better.

  14. Fog camera to visualize ionizing charged particles

    International Nuclear Information System (INIS)

    Trujillo A, L.; Rodriguez R, N. I.; Vega C, H. R.

    2014-10-01

    The human being can not perceive the different types of ionizing radiation, natural or artificial, present in the nature, for what appropriate detection systems have been developed according to the sensibility to certain radiation type and certain energy type. The objective of this work was to build a fog camera to visualize the traces, and to identify the trajectories, produced by charged particles with high energy, coming mainly of the cosmic rays. The origin of the cosmic rays comes from the solar radiation generated by solar eruptions where the protons compose most of this radiation. It also comes, of the galactic radiation which is composed mainly of charged particles and gamma rays that comes from outside of the solar system. These radiation types have energy time millions higher that those detected in the earth surface, being more important as the height on the sea level increases. These particles in their interaction produce secondary particles that are detectable by means of this cameras type. The camera operates by means of a saturated atmosphere of alcohol vapor. In the moment in that a charged particle crosses the cold area of the atmosphere, the medium is ionized and the particle acts like a condensation nucleus of the alcohol vapor, leaving a visible trace of its trajectory. The built camera was very stable, allowing the detection in continuous form and the observation of diverse events. (Author)

  15. [Camera-cinematography of the heart (author's transl)].

    Science.gov (United States)

    Adam, W E; Meyer, G; Bitter, F; Kampmann, H; Bargon, G; Stauch, M

    1975-07-01

    By "camera-cinematography" of the heart, we mean an isotope method which permits detailed observation of cardiac mechanics without the use of a catheter. All that is necessary is an intravenous injection of 10 to 15 mCi 99mTc human serum albumen followed after ten minutes by a five to ten minute period of observation with a scintilation camera. At this time the isotope has become distributed in the blood. Variations in the precordial impulses correspond with intra-cardiac changes of blood volume during a cardiac cycle. Analysis of the R-wave provides adequate information of cyclical volume changes in limited portions of the heart. This is achieved by a monitor with a pseudo-3-dimensional display; contraction and relaxation of the myocardium can be shown for any chosen longitudinal or horizontal diameter of the heart. Our programme allows simultaneous presentation of the movement of any point on the myocardium as a time-activity curve. The method is recommended as an addition to chest radiography, heart screening or cardiac kymography before carrying out cardiac catheterisation.

  16. Human tracking over camera networks: a review

    Science.gov (United States)

    Hou, Li; Wan, Wanggen; Hwang, Jenq-Neng; Muhammad, Rizwan; Yang, Mingyang; Han, Kang

    2017-12-01

    In recent years, automated human tracking over camera networks is getting essential for video surveillance. The tasks of tracking human over camera networks are not only inherently challenging due to changing human appearance, but also have enormous potentials for a wide range of practical applications, ranging from security surveillance to retail and health care. This review paper surveys the most widely used techniques and recent advances for human tracking over camera networks. Two important functional modules for the human tracking over camera networks are addressed, including human tracking within a camera and human tracking across non-overlapping cameras. The core techniques of human tracking within a camera are discussed based on two aspects, i.e., generative trackers and discriminative trackers. The core techniques of human tracking across non-overlapping cameras are then discussed based on the aspects of human re-identification, camera-link model-based tracking and graph model-based tracking. Our survey aims to address existing problems, challenges, and future research directions based on the analyses of the current progress made toward human tracking techniques over camera networks.

  17. Using Imagers for Scaling Ecological Observations

    OpenAIRE

    Graham, Eric; Hicks, John; Riordan, Erin; Wang, Eric; Yuen, Eric

    2009-01-01

    Stationary and mobile ground-based cameras can be used to scale ecological observations, relating pixel information in images to in situ measurements. Currently there are four CENS projects that involve using cameras for scaling ecological observations: 1. Scaling from one individual to the landscape. Pan-Tilt-Zoom cameras can be zoomed in on a tight focus on individual plants and parts of individuals and then zoomed out to get a landscape view, composed of the same and similar species. 2...

  18. Towards Adaptive Virtual Camera Control In Computer Games

    DEFF Research Database (Denmark)

    Burelli, Paolo; Yannakakis, Georgios N.

    2011-01-01

    Automatic camera control aims to define a framework to control virtual camera movements in dynamic and unpredictable virtual environments while ensuring a set of desired visual properties. We inves- tigate the relationship between camera placement and playing behaviour in games and build a user...... model of the camera behaviour that can be used to control camera movements based on player preferences. For this purpose, we collect eye gaze, camera and game-play data from subjects playing a 3D platform game, we cluster gaze and camera information to identify camera behaviour profiles and we employ...... camera control in games is discussed....

  19. Black leaf streak disease affects starch metabolism in banana fruit.

    Science.gov (United States)

    Saraiva, Lorenzo de Amorim; Castelan, Florence Polegato; Shitakubo, Renata; Hassimotto, Neuza Mariko Aymoto; Purgatto, Eduardo; Chillet, Marc; Cordenunsi, Beatriz Rosana

    2013-06-12

    Black leaf streak disease (BLSD), also known as black sigatoka, represents the main foliar disease in Brazilian banana plantations. In addition to photosynthetic leaf area losses and yield losses, this disease causes an alteration in the pre- and postharvest behavior of the fruit. The aim of this work was to investigate the starch metabolism of fruits during fruit ripening from plants infected with BLSD by evaluating carbohydrate content (i.e., starch, soluble sugars, oligosaccharides, amylose), phenolic compound content, phytohormones, enzymatic activities (i.e., starch phosphorylases, α- and β-amylase), and starch granules. The results indicated that the starch metabolism in banana fruit ripening is affected by BLSD infection. Fruit from infested plots contained unusual amounts of soluble sugars in the green stage and smaller starch granules and showed a different pattern of superficial degradation. Enzymatic activities linked to starch degradation were also altered by the disease. Moreover, the levels of indole-acetic acid and phenolic compounds indicated an advanced fruit physiological age for fruits from infested plots.

  20. Loop-mediated Isothermal Amplification Assay to Rapidly Detect Wheat Streak Mosaic Virus in Quarantined Plants

    Directory of Open Access Journals (Sweden)

    Siwon Lee

    2015-12-01

    Full Text Available We developed a loop-mediated isothermal amplification (LAMP method to rapidly diagnose Wheat streak mosaic virus (WSMV during quarantine inspections of imported wheat, corn, oats, and millet. The LAMP method was developed as a plant quarantine inspection method for the first time, and its simplicity, quickness, specificity and sensitivity were verified compared to current reverse transcription-polymerase chain reaction (RT-PCR and nested PCR quarantine methods. We were able to quickly screen for WSMV at quarantine sites with many test samples; thus, this method is expected to contribute to plant quarantine inspections.

  1. Dynamic gamma camera scintigraphy in primary hypoovarism

    International Nuclear Information System (INIS)

    Peshev, N.; Mladenov, B.; Topalov, I.; Tsanev, Ts.

    1988-01-01

    Twenty-seven patients with primary hypoovarism and 10 controls were examined. After intravenous injection of 111 to 175 MBq 99m Tc pertechnetate, dynamic gamma camera scintigraphy for 15 minutes was carried out. In the patients with primary amenorrhea no functioning ovarial tissue was visualized or the ovaries were diminished in size, strongly reduced and non-homogenous accumulation of the radionuclide with unclear and uneven delineation were observed. In the patients with primary infertility, the gamma camera investigation gave information not only about the presence of ovarial parenchyma, but about the extent of the inflammatory process, too. In the patients after surgical intervention, the dynamic radioisotope investigation gave information about the volume and the site of the surgical intervention, as well as about the conditions of the residual parenchyma

  2. Hardware Middleware for Person Tracking on Embedded Distributed Smart Cameras

    Directory of Open Access Journals (Sweden)

    Ali Akbar Zarezadeh

    2012-01-01

    Full Text Available Tracking individuals is a prominent application in such domains like surveillance or smart environments. This paper provides a development of a multiple camera setup with jointed view that observes moving persons in a site. It focuses on a geometry-based approach to establish correspondence among different views. The expensive computational parts of the tracker are hardware accelerated via a novel system-on-chip (SoC design. In conjunction with this vision application, a hardware object request broker (ORB middleware is presented as the underlying communication system. The hardware ORB provides a hardware/software architecture to achieve real-time intercommunication among multiple smart cameras. Via a probing mechanism, a performance analysis is performed to measure network latencies, that is, time traversing the TCP/IP stack, in both software and hardware ORB approaches on the same smart camera platform. The empirical results show that using the proposed hardware ORB as client and server in separate smart camera nodes will considerably reduce the network latency up to 100 times compared to the software ORB.

  3. An assessment of the effectiveness of high definition cameras as remote monitoring tools for dolphin ecology studies.

    Directory of Open Access Journals (Sweden)

    Estênio Guimarães Paiva

    Full Text Available Research involving marine mammals often requires costly field programs. This paper assessed whether the benefits of using cameras outweighs the implications of having personnel performing marine mammal detection in the field. The efficacy of video and still cameras to detect Indo-Pacific bottlenose dolphins (Tursiops aduncus in the Fremantle Harbour (Western Australia was evaluated, with consideration on how environmental conditions affect detectability. The cameras were set on a tower in the Fremantle Port channel and videos were perused at 1.75 times the normal speed. Images from the cameras were used to estimate position of dolphins at the water's surface. Dolphin detections ranged from 5.6 m to 463.3 m for the video camera, and from 10.8 m to 347.8 m for the still camera. Detection range showed to be satisfactory when compared to distances at which dolphins would be detected by field observers. The relative effect of environmental conditions on detectability was considered by fitting a Generalised Estimation Equations (GEEs model with Beaufort, level of glare and their interactions as predictors and a temporal auto-correlation structure. The best fit model indicated level of glare had an effect, with more intense periods of glare corresponding to lower occurrences of observed dolphins. However this effect was not large (-0.264 and the parameter estimate was associated with a large standard error (0.113. The limited field of view was the main restraint in that cameras can be only applied to detections of animals observed rather than counts of individuals. However, the use of cameras was effective for long term monitoring of occurrence of dolphins, outweighing the costs and reducing the health and safety risks to field personal. This study showed that cameras could be effectively implemented onshore for research such as studying changes in habitat use in response to development and construction activities.

  4. On-Line High Dose-Rate Gamma Ray Irradiation Test of the CCD/CMOS Cameras

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Wan; Jeong, Kyung Min [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    dose rate of about 150 Gy/h till these cameras failed. A high dose-rate gamma ray radiation induced speckles in the camera image were heavily observed. In this paper we describe the evolution of their basic characteristics with high dose rate gamma irradiation and shortly explain the observed phenomena

  5. Comparative analysis of virus-derived small RNAs within cassava (Manihot esculenta Crantz) infected with cassava brown streak viruses.

    Science.gov (United States)

    Ogwok, Emmanuel; Ilyas, Muhammad; Alicai, Titus; Rey, Marie E C; Taylor, Nigel J

    2016-04-02

    Infection of plant cells by viral pathogens triggers RNA silencing, an innate antiviral defense mechanism. In response to infection, small RNAs (sRNAs) are produced that associate with Argonaute (AGO)-containing silencing complexes which act to inactivate viral genomes by posttranscriptional gene silencing (PTGS). Deep sequencing was used to compare virus-derived small RNAs (vsRNAs) in cassava genotypes NASE 3, TME 204 and 60444 infected with the positive sense single-stranded RNA (+ssRNA) viruses cassava brown streak virus (CBSV) and Ugandan cassava brown streak virus (UCBSV), the causal agents of cassava brown streak disease (CBSD). An abundance of 21-24nt vsRNAs was detected and mapped, covering the entire CBSV and UCBSV genomes. The 21nt vsRNAs were most predominant, followed by the 22 nt class with a slight bias toward sense compared to antisense polarity, and a bias for adenine and uracil bases present at the 5'-terminus. Distribution and frequency of vsRNAs differed between cassava genotypes and viral genomes. In susceptible genotypes TME 204 and 60444, CBSV-derived sRNAs were seen in greater abundance than UCBSV-derived sRNAs. NASE 3, known to be resistant to UCBSV, accumulated negligible UCBSV-derived sRNAs but high populations of CBSV-derived sRNAs. Transcript levels of cassava homologues of AGO2, DCL2 and DCL4, which are central to the gene-silencing complex, were found to be differentially regulated in CBSV- and UCBSV-infected plants across genotypes, suggesting these proteins play a role in antiviral defense. Irrespective of genotype or viral pathogen, maximum populations of vsRNAs mapped to the cytoplasmic inclusion, P1 and P3 protein-encoding regions. Our results indicate disparity between CBSV and UCBSV host-virus interaction mechanisms, and provide insight into the role of virus-induced gene silencing as a mechanism of resistance to CBSD. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  6. Automatic camera tracking for remote manipulators

    International Nuclear Information System (INIS)

    Stoughton, R.S.; Martin, H.L.; Bentz, R.R.

    1984-07-01

    The problem of automatic camera tracking of mobile objects is addressed with specific reference to remote manipulators and using either fixed or mobile cameras. The technique uses a kinematic approach employing 4 x 4 coordinate transformation matrices to solve for the needed camera PAN and TILT angles. No vision feedback systems are used, as the required input data are obtained entirely from position sensors from the manipulator and the camera-positioning system. All hardware requirements are generally satisfied by currently available remote manipulator systems with a supervisory computer. The system discussed here implements linear plus on/off (bang-bang) closed-loop control with a +-2-deg deadband. The deadband area is desirable to avoid operator seasickness caused by continuous camera movement. Programming considerations for camera control, including operator interface options, are discussed. The example problem presented is based on an actual implementation using a PDP 11/34 computer, a TeleOperator Systems SM-229 manipulator, and an Oak Ridge National Laboratory (ORNL) camera-positioning system. 3 references, 6 figures, 2 tables

  7. Automatic camera tracking for remote manipulators

    International Nuclear Information System (INIS)

    Stoughton, R.S.; Martin, H.L.; Bentz, R.R.

    1984-04-01

    The problem of automatic camera tracking of mobile objects is addressed with specific reference to remote manipulators and using either fixed or mobile cameras. The technique uses a kinematic approach employing 4 x 4 coordinate transformation matrices to solve for the needed camera PAN and TILT angles. No vision feedback systems are used, as the required input data are obtained entirely from position sensors from the manipulator and the camera-positioning system. All hardware requirements are generally satisfied by currently available remote manipulator systems with a supervisory computer. The system discussed here implements linear plus on/off (bang-bang) closed-loop control with a +-2 0 deadband. The deadband area is desirable to avoid operator seasickness caused by continuous camera movement. Programming considerations for camera control, including operator interface options, are discussed. The example problem presented is based on an actual implementation using a PDP 11/34 computer, a TeleOperator Systems SM-229 manipulator, and an Oak Ridge National Laboratory (ORNL) camera-positioning system. 3 references, 6 figures, 2 tables

  8. Molecular insights into Cassava brown streak virus susceptibility and resistance by profiling of the early host response

    OpenAIRE

    Anjanappa, Ravi B; Mehta, Devang; Okoniewski, Michal J; Szabelska-Berȩsewicz, Alicja; Gruissem, Wilhelm; Vanderschuren, Hervé

    2018-01-01

    Cassava brown streak viruses (CBSVs) are responsible for significant cassava yield losses in eastern sub-Saharan Africa. To study the possible mechanisms of plant resistance to CBSVs we inoculated CBSV-susceptible and -resistant cassava varieties with a mixed infection of CBSVs using top-cleft grafting. Transcriptome profiling of the two cassava varieties was performed at the earliest time-point of full infection (28 days after grafting) in the susceptible scions. The expression of genes enco...

  9. Rapid objective measurement of gamma camera resolution using statistical moments.

    Science.gov (United States)

    Hander, T A; Lancaster, J L; Kopp, D T; Lasher, J C; Blumhardt, R; Fox, P T

    1997-02-01

    An easy and rapid method for the measurement of the intrinsic spatial resolution of a gamma camera was developed. The measurement is based on the first and second statistical moments of regions of interest (ROIs) applied to bar phantom images. This leads to an estimate of the modulation transfer function (MTF) and the full-width-at-half-maximum (FWHM) of a line spread function (LSF). Bar phantom images were acquired using four large field-of-view (LFOV) gamma cameras (Scintronix, Picker, Searle, Siemens). The following factors important for routine measurements of gamma camera resolution with this method were tested: ROI placement and shape, phantom orientation, spatial sampling, and procedural consistency. A 0.2% coefficient of variation (CV) between repeat measurements of MTF was observed for a circular ROI. The CVs of less than 2% were observed for measured MTF values for bar orientations ranging from -10 degrees to +10 degrees with respect to the x and y axes of the camera acquisition matrix. A 256 x 256 matrix (1.6 mm pixel spacing) was judged sufficient for routine measurements, giving an estimate of the FWHM to within 0.1 mm of manufacturer-specified values (3% difference). Under simulated clinical conditions, the variation in measurements attributable to procedural effects yielded a CV of less than 2% in newer generation cameras. The moments method for determining MTF correlated well with a peak-valley method, with an average difference of 0.03 across the range of spatial frequencies tested (0.11-0.17 line pairs/mm, corresponding to 4.5-3.0 mm bars). When compared with the NEMA method for measuring intrinsic spatial resolution, the moments method was found to be within 4% of the expected FWHM.

  10. Gamma camera system

    International Nuclear Information System (INIS)

    Miller, D.W.; Gerber, M.S.; Schlosser, P.A.; Steidley, J.W.

    1980-01-01

    A detailed description is given of a novel gamma camera which is designed to produce superior images than conventional cameras used in nuclear medicine. The detector consists of a solid state detector (e.g. germanium) which is formed to have a plurality of discrete components to enable 2-dimensional position identification. Details of the electronic processing circuits are given and the problems and limitations introduced by noise are discussed in full. (U.K.)

  11. Structure-From for Calibration of a Vehicle Camera System with Non-Overlapping Fields-Of in AN Urban Environment

    Science.gov (United States)

    Hanel, A.; Stilla, U.

    2017-05-01

    Vehicle environment cameras observing traffic participants in the area around a car and interior cameras observing the car driver are important data sources for driver intention recognition algorithms. To combine information from both camera groups, a camera system calibration can be performed. Typically, there is no overlapping field-of-view between environment and interior cameras. Often no marked reference points are available in environments, which are a large enough to cover a car for the system calibration. In this contribution, a calibration method for a vehicle camera system with non-overlapping camera groups in an urban environment is described. A-priori images of an urban calibration environment taken with an external camera are processed with the structure-frommotion method to obtain an environment point cloud. Images of the vehicle interior, taken also with an external camera, are processed to obtain an interior point cloud. Both point clouds are tied to each other with images of both image sets showing the same real-world objects. The point clouds are transformed into a self-defined vehicle coordinate system describing the vehicle movement. On demand, videos can be recorded with the vehicle cameras in a calibration drive. Poses of vehicle environment cameras and interior cameras are estimated separately using ground control points from the respective point cloud. All poses of a vehicle camera estimated for different video frames are optimized in a bundle adjustment. In an experiment, a point cloud is created from images of an underground car park, as well as a point cloud of the interior of a Volkswagen test car is created. Videos of two environment and one interior cameras are recorded. Results show, that the vehicle camera poses are estimated successfully especially when the car is not moving. Position standard deviations in the centimeter range can be achieved for all vehicle cameras. Relative distances between the vehicle cameras deviate between

  12. The eye of the camera: effects of security cameras on pro-social behavior

    NARCIS (Netherlands)

    van Rompay, T.J.L.; Vonk, D.J.; Fransen, M.L.

    2009-01-01

    This study addresses the effects of security cameras on prosocial behavior. Results from previous studies indicate that the presence of others can trigger helping behavior, arising from the need for approval of others. Extending these findings, the authors propose that security cameras can likewise

  13. Passive auto-focus for digital still cameras and camera phones: Filter-switching and low-light techniques

    Science.gov (United States)

    Gamadia, Mark Noel

    In order to gain valuable market share in the growing consumer digital still camera and camera phone market, camera manufacturers have to continually add and improve existing features to their latest product offerings. Auto-focus (AF) is one such feature, whose aim is to enable consumers to quickly take sharply focused pictures with little or no manual intervention in adjusting the camera's focus lens. While AF has been a standard feature in digital still and cell-phone cameras, consumers often complain about their cameras' slow AF performance, which may lead to missed photographic opportunities, rendering valuable moments and events with undesired out-of-focus pictures. This dissertation addresses this critical issue to advance the state-of-the-art in the digital band-pass filter, passive AF method. This method is widely used to realize AF in the camera industry, where a focus actuator is adjusted via a search algorithm to locate the in-focus position by maximizing a sharpness measure extracted from a particular frequency band of the incoming image of the scene. There are no known systematic methods for automatically deriving the parameters such as the digital pass-bands or the search step-size increments used in existing passive AF schemes. Conventional methods require time consuming experimentation and tuning in order to arrive at a set of parameters which balance AF performance in terms of speed and accuracy ultimately causing a delay in product time-to-market. This dissertation presents a new framework for determining an optimal set of passive AF parameters, named Filter- Switching AF, providing an automatic approach to achieve superior AF performance, both in good and low lighting conditions based on the following performance measures (metrics): speed (total number of iterations), accuracy (offset from truth), power consumption (total distance moved), and user experience (in-focus position overrun). Performance results using three different prototype cameras

  14. ROBUST PERSON TRACKING WITH MULTIPLE NON-OVERLAPPING CAMERAS IN AN OUTDOOR ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    S. Hellwig

    2012-07-01

    Full Text Available The aim of our work is to combine multiple cameras for a robust tracking of persons in an outdoor environment. Although surveillance is a well established field, many algorithms apply various constraints like overlapping fields of view or precise calibration of the cameras to improve results. An application of these developed systems in a realistic outdoor environment is often difficult. Our aim is to be widely independent from the camera setup and the observed scene, in order to use existing cameras. Thereby our algorithm needs to be capable to work with both overlapping and non-overlapping fields of views. We propose an algorithm that allows flexible combination of different static cameras with varying properties. Another requirement of a practical application is that the algorithm is able to work online. Our system is able to process the data during runtime and to provide results immediately. In addition to seeking flexibility in the camera setup, we present a specific approach that combines state of the art algorithms in order to be robust to environment influences. We present results that indicate a good performance of our introduced algorithm in different scenarios. We show its robustness to different types of image artifacts. In addition we demonstrate that our algorithm is able to match persons between cameras in a non-overlapping scenario.

  15. Image compensation for camera and lighting variability

    Science.gov (United States)

    Daley, Wayne D.; Britton, Douglas F.

    1996-12-01

    With the current trend of integrating machine vision systems in industrial manufacturing and inspection applications comes the issue of camera and illumination stabilization. Unless each application is built around a particular camera and highly controlled lighting environment, the interchangeability of cameras of fluctuations in lighting become a problem as each camera usually has a different response. An empirical approach is proposed where color tile data is acquired using the camera of interest, and a mapping is developed to some predetermined reference image using neural networks. A similar analytical approach based on a rough analysis of the imaging systems is also considered for deriving a mapping between cameras. Once a mapping has been determined, all data from one camera is mapped to correspond to the images of the other prior to performing any processing on the data. Instead of writing separate image processing algorithms for the particular image data being received, the image data is adjusted based on each particular camera and lighting situation. All that is required when swapping cameras is the new mapping for the camera being inserted. The image processing algorithms can remain the same as the input data has been adjusted appropriately. The results of utilizing this technique are presented for an inspection application.

  16. Optimising camera traps for monitoring small mammals.

    Directory of Open Access Journals (Sweden)

    Alistair S Glen

    Full Text Available Practical techniques are required to monitor invasive animals, which are often cryptic and occur at low density. Camera traps have potential for this purpose, but may have problems detecting and identifying small species. A further challenge is how to standardise the size of each camera's field of view so capture rates are comparable between different places and times. We investigated the optimal specifications for a low-cost camera trap for small mammals. The factors tested were 1 trigger speed, 2 passive infrared vs. microwave sensor, 3 white vs. infrared flash, and 4 still photographs vs. video. We also tested a new approach to standardise each camera's field of view. We compared the success rates of four camera trap designs in detecting and taking recognisable photographs of captive stoats (Mustelaerminea, feral cats (Felis catus and hedgehogs (Erinaceuseuropaeus. Trigger speeds of 0.2-2.1 s captured photographs of all three target species unless the animal was running at high speed. The camera with a microwave sensor was prone to false triggers, and often failed to trigger when an animal moved in front of it. A white flash produced photographs that were more readily identified to species than those obtained under infrared light. However, a white flash may be more likely to frighten target animals, potentially affecting detection probabilities. Video footage achieved similar success rates to still cameras but required more processing time and computer memory. Placing two camera traps side by side achieved a higher success rate than using a single camera. Camera traps show considerable promise for monitoring invasive mammal control operations. Further research should address how best to standardise the size of each camera's field of view, maximise the probability that an animal encountering a camera trap will be detected, and eliminate visible or audible cues emitted by camera traps.

  17. Science, conservation, and camera traps

    Science.gov (United States)

    Nichols, James D.; Karanth, K. Ullas; O'Connel, Allan F.; O'Connell, Allan F.; Nichols, James D.; Karanth, K. Ullas

    2011-01-01

    Biologists commonly perceive camera traps as a new tool that enables them to enter the hitherto secret world of wild animals. Camera traps are being used in a wide range of studies dealing with animal ecology, behavior, and conservation. Our intention in this volume is not to simply present the various uses of camera traps, but to focus on their use in the conduct of science and conservation. In this chapter, we provide an overview of these two broad classes of endeavor and sketch the manner in which camera traps are likely to be able to contribute to them. Our main point here is that neither photographs of individual animals, nor detection history data, nor parameter estimates generated from detection histories are the ultimate objective of a camera trap study directed at either science or management. Instead, the ultimate objectives are best viewed as either gaining an understanding of how ecological systems work (science) or trying to make wise decisions that move systems from less desirable to more desirable states (conservation, management). Therefore, we briefly describe here basic approaches to science and management, emphasizing the role of field data and associated analyses in these processes. We provide examples of ways in which camera trap data can inform science and management.

  18. Transcriptional changes of rice in response to rice black-streaked dwarf virus.

    Science.gov (United States)

    Ahmed, Mohamed M S; Ji, Wen; Wang, Muyue; Bian, Shiquan; Xu, Meng; Wang, Weiyun; Zhang, Jiangxiang; Xu, Zhihao; Yu, Meimei; Liu, Qiaoquan; Zhang, Changquan; Zhang, Honggen; Tang, Shuzhu; Gu, Minghong; Yu, Hengxiu

    2017-09-10

    Rice black-streaked dwarf virus (RBSDV), a member of the genus Fijivirus in the family Reoviridae, causes significant economic losses in rice production in China and many other Asian countries. Although a great deal of effort has been made to elucidate the interactions among the virus, insect vectors, host and environmental conditions, few RBSDV proteins involved in pathogenesis have been identified, and the biological basis of disease development in rice remains largely unknown. Transcriptomic information associated with the disease development in rice would be helpful to unravel the biological mechanism. To determine how the rice transcriptome changes in response to RBSDV infection, we carried out RNA-Seq to perform a genome-wide gene expression analysis of a susceptible rice cultivar KTWYJ3. The transcriptomes of RBSDV-infected samples were compared to those of RBSDV-free (healthy) at two time points (time points are represented by group I and II). The results derived from the differential expression analysis in RBSDV-infected libraries vs. healthy ones in group I revealed that 102 out of a total of 281 significant differentially expressed genes (DEGs) were up-regulated and 179 DEGs were down-regulated. Of the 2592 identified DEGs in group II, 1588 DEGs were up-regulated and 1004 DEGs were down-regulated. A total of 66 DEGs were commonly identified in both groups. Of these 66 DEGs, expression patterns for 36 DEGs were similar in both groups. Our analysis demonstrated that some genes related to disease defense and stress resistance were up-regulated while genes associated with chloroplast were down-regulated in response to RBSDV infection. In addition, some genes associated with plant-height were differentially expressed. This result indicates those genes might be involved in dwarf symptoms caused by RBSDV. Taken together, our results provide a genome-wide transcriptome analysis for rice plants in response to RBSDV infection which may contribute to the

  19. New camera systems for fuel services

    International Nuclear Information System (INIS)

    Hummel, W.; Beck, H.J.

    2010-01-01

    AREVA NP Fuel Services have many years of experience in visual examination and measurements on fuel assemblies and associated core components by using state of the art cameras and measuring technologies. The used techniques allow the surface and dimensional characterization of materials and shapes by visual examination. New enhanced and sophisticated technologies for fuel services f. e. are two shielded color camera systems for use under water and close inspection of a fuel assembly. Nowadays the market requirements for detecting and characterization of small defects (lower than the 10th of one mm) or cracks and analyzing surface appearances on an irradiated fuel rod cladding or fuel assembly structure parts have increased. Therefore it is common practice to use movie cameras with higher resolution. The radiation resistance of high resolution CCD cameras is in general very low and it is not possible to use them unshielded close to a fuel assembly. By extending the camera with a mirror system and shielding around the sensitive parts, the movie camera can be utilized for fuel assembly inspection. AREVA NP Fuel Services is now equipped with such kind of movie cameras. (orig.)

  20. Power estimation of martial arts movement using 3D motion capture camera

    Science.gov (United States)

    Azraai, Nur Zaidi; Awang Soh, Ahmad Afiq Sabqi; Mat Jafri, Mohd Zubir

    2017-06-01

    Motion capture camera (MOCAP) has been widely used in many areas such as biomechanics, physiology, animation, arts, etc. This project is done by approaching physics mechanics and the extended of MOCAP application through sports. Most researchers will use a force plate, but this will only can measure the force of impact, but for us, we are keen to observe the kinematics of the movement. Martial arts is one of the sports that uses more than one part of the human body. For this project, martial art `Silat' was chosen because of its wide practice in Malaysia. 2 performers have been selected, one of them has an experienced in `Silat' practice and another one have no experience at all so that we can compare the energy and force generated by the performers. Every performer will generate a punching with same posture which in this project, two types of punching move were selected. Before the measuring start, a calibration has been done so the software knows the area covered by the camera and reduce the error when analyze by using the T stick that have been pasted with a marker. A punching bag with mass 60 kg was hung on an iron bar as a target. The use of this punching bag is to determine the impact force of a performer when they punch. This punching bag also will be stuck with the optical marker so we can observe the movement after impact. 8 cameras have been used and placed with 2 cameras at every side of the wall with different angle in a rectangular room 270 ft2 and the camera covered approximately 50 ft2. We covered only a small area so less noise will be detected and make the measurement more accurate. A Marker has been pasted on the limb of the entire hand that we want to observe and measure. A passive marker used in this project has a characteristic to reflect the infrared that being generated by the camera. The infrared will reflected to the camera sensor so the marker position can be detected and show in software. The used of many cameras is to increase the

  1. Ultrafast laser pump/x-ray probe experiments

    International Nuclear Information System (INIS)

    Larsson, J.; Judd, E.; Schuck, P.J.

    1997-01-01

    In an ongoing project aimed at probing solids using x-rays obtained at the ALS synchrotron with a sub-picosecond time resolution following interactions with a 100 fs laser pulse, the authors have successfully performed pump-probe experiments limited by the temporal duration of ALS-pulse. They observe a drop in the diffraction efficiency following laser heating. They can attribute this to a disordering of the crystal. Studies with higher temporal resolution are required to determine the mechanism. The authors have also incorporated a low-jitter streakcamera as a diagnostic for observing time-dependant x-ray diffraction. The streakcamera triggered by a photoconductive switch was operated at kHz repetition rates. Using UV-pulses, the authors obtain a temporal response of 2 ps when averaging 5000 laser pulses. They demonstrate the ability to detect monochromatized x-ray radiation from a bend-magnet with the streak camera by measuring the pulse duration of a x-ray pulse to 70 ps. In conclusion, the authors show a rapid disordering of an InSb crystal. The resolution was determined by the duration of the ALS pulse. They also demonstrate that they can detect x-ray radiation from a synchrotron source with a temporal resolution of 2ps, by using an ultrafast x-ray streak camera. Their set-up will allow them to pursue laser pump/x-ray probe experiments to monitor structural changes in materials with ultrafast time resolution

  2. Photocathode development

    International Nuclear Information System (INIS)

    Hinrichs, C.K.; Estrella, R.M.

    1979-01-01

    A research program for the development of photocathodes for use in streak image tubes is described. This is one task in the development of a high-resolution, high-speed x-ray streak camera system whose primary application is for diagnostics in underground nuclear testing. There are three objectives in the photocathode development program: (1) the development of new x-ray photocathodes compatible with the requirements of streak tubes; (2) the development of the capability to process high-quality visible light photocathodes as well as x-ray photocathodes; and (3) the design and construction of a transfer photocathode system. Design and construction of all the major components of the transfer photocathode system were completed. Assembly should be completed in early FY 80

  3. Automatic multi-camera calibration for deployable positioning systems

    Science.gov (United States)

    Axelsson, Maria; Karlsson, Mikael; Rudner, Staffan

    2012-06-01

    Surveillance with automated positioning and tracking of subjects and vehicles in 3D is desired in many defence and security applications. Camera systems with stereo or multiple cameras are often used for 3D positioning. In such systems, accurate camera calibration is needed to obtain a reliable 3D position estimate. There is also a need for automated camera calibration to facilitate fast deployment of semi-mobile multi-camera 3D positioning systems. In this paper we investigate a method for automatic calibration of the extrinsic camera parameters (relative camera pose and orientation) of a multi-camera positioning system. It is based on estimation of the essential matrix between each camera pair using the 5-point method for intrinsically calibrated cameras. The method is compared to a manual calibration method using real HD video data from a field trial with a multicamera positioning system. The method is also evaluated on simulated data from a stereo camera model. The results show that the reprojection error of the automated camera calibration method is close to or smaller than the error for the manual calibration method and that the automated calibration method can replace the manual calibration.

  4. Towards next generation 3D cameras

    Science.gov (United States)

    Gupta, Mohit

    2017-03-01

    We are in the midst of a 3D revolution. Robots enabled by 3D cameras are beginning to autonomously drive cars, perform surgeries, and manage factories. However, when deployed in the real-world, these cameras face several challenges that prevent them from measuring 3D shape reliably. These challenges include large lighting variations (bright sunlight to dark night), presence of scattering media (fog, body tissue), and optically complex materials (metal, plastic). Due to these factors, 3D imaging is often the bottleneck in widespread adoption of several key robotics technologies. I will talk about our work on developing 3D cameras based on time-of-flight and active triangulation that addresses these long-standing problems. This includes designing `all-weather' cameras that can perform high-speed 3D scanning in harsh outdoor environments, as well as cameras that recover shape of objects with challenging material properties. These cameras are, for the first time, capable of measuring detailed (robotic inspection and assembly systems.

  5. Multi-Angle Snowflake Camera Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Stuefer, Martin [Univ. of Alaska, Fairbanks, AK (United States); Bailey, J. [Univ. of Alaska, Fairbanks, AK (United States)

    2016-07-01

    The Multi-Angle Snowflake Camera (MASC) takes 9- to 37-micron resolution stereographic photographs of free-falling hydrometers from three angles, while simultaneously measuring their fall speed. Information about hydrometeor size, shape orientation, and aspect ratio is derived from MASC photographs. The instrument consists of three commercial cameras separated by angles of 36º. Each camera field of view is aligned to have a common single focus point about 10 cm distant from the cameras. Two near-infrared emitter pairs are aligned with the camera’s field of view within a 10-angular ring and detect hydrometeor passage, with the lower emitters configured to trigger the MASC cameras. The sensitive IR motion sensors are designed to filter out slow variations in ambient light. Fall speed is derived from successive triggers along the fall path. The camera exposure times are extremely short, in the range of 1/25,000th of a second, enabling the MASC to capture snowflake sizes ranging from 30 micrometers to 3 cm.

  6. CALIBRATION PROCEDURES ON OBLIQUE CAMERA SETUPS

    Directory of Open Access Journals (Sweden)

    G. Kemper

    2016-06-01

    Full Text Available Beside the creation of virtual animated 3D City models, analysis for homeland security and city planning, the accurately determination of geometric features out of oblique imagery is an important task today. Due to the huge number of single images the reduction of control points force to make use of direct referencing devices. This causes a precise camera-calibration and additional adjustment procedures. This paper aims to show the workflow of the various calibration steps and will present examples of the calibration flight with the final 3D City model. In difference to most other software, the oblique cameras are used not as co-registered sensors in relation to the nadir one, all camera images enter the AT process as single pre-oriented data. This enables a better post calibration in order to detect variations in the single camera calibration and other mechanical effects. The shown sensor (Oblique Imager is based o 5 Phase One cameras were the nadir one has 80 MPIX equipped with a 50 mm lens while the oblique ones capture images with 50 MPix using 80 mm lenses. The cameras are mounted robust inside a housing to protect this against physical and thermal deformations. The sensor head hosts also an IMU which is connected to a POS AV GNSS Receiver. The sensor is stabilized by a gyro-mount which creates floating Antenna –IMU lever arms. They had to be registered together with the Raw GNSS-IMU Data. The camera calibration procedure was performed based on a special calibration flight with 351 shoots of all 5 cameras and registered the GPS/IMU data. This specific mission was designed in two different altitudes with additional cross lines on each flying heights. The five images from each exposure positions have no overlaps but in the block there are many overlaps resulting in up to 200 measurements per points. On each photo there were in average 110 well distributed measured points which is a satisfying number for the camera calibration. In a first

  7. Relative and Absolute Calibration of a Multihead Camera System with Oblique and Nadir Looking Cameras for a Uas

    Science.gov (United States)

    Niemeyer, F.; Schima, R.; Grenzdörffer, G.

    2013-08-01

    Numerous unmanned aerial systems (UAS) are currently flooding the market. For the most diverse applications UAVs are special designed and used. Micro and mini UAS (maximum take-off weight up to 5 kg) are of particular interest, because legal restrictions are still manageable but also the payload capacities are sufficient for many imaging sensors. Currently a camera system with four oblique and one nadir looking cameras is under development at the Chair for Geodesy and Geoinformatics. The so-called "Four Vision" camera system was successfully built and tested in the air. A MD4-1000 UAS from microdrones is used as a carrier system. Light weight industrial cameras are used and controlled by a central computer. For further photogrammetric image processing, each individual camera, as well as all the cameras together have to be calibrated. This paper focuses on the determination of the relative orientation between the cameras with the „Australis" software and will give an overview of the results and experiences of test flights.

  8. Heard Island and McDonald Islands Acoustic Plumes: Split-beam Echo sounder and Deep Tow Camera Observations of Gas Seeps on the Central Kerguelen Plateau

    Science.gov (United States)

    Watson, S. J.; Spain, E. A.; Coffin, M. F.; Whittaker, J. M.; Fox, J. M.; Bowie, A. R.

    2016-12-01

    Heard and McDonald islands (HIMI) are two active volcanic edifices on the Central Kerguelen Plateau. Scientists aboard the Heard Earth-Ocean-Biosphere Interactions voyage in early 2016 explored how this volcanic activity manifests itself near HIMI. Using Simrad EK60 split-beam echo sounder and deep tow camera data from RV Investigator, we recorded the distribution of seafloor emissions, providing the first direct evidence of seabed discharge around HIMI, mapping >244 acoustic plume signals. Northeast of Heard, three distinct plume clusters are associated with bubbles (towed camera) and the largest directly overlies a sub-seafloor opaque zone (sub-bottom profiler) with >140 zones observed within 6.5 km. Large temperature anomalies did not characterize any of the acoustic plumes where temperature data were recorded. We therefore suggest that these plumes are cold methane seeps. Acoustic properties - mean volume backscattering and target strength - and morphology - height, width, depth to surface - of plumes around McDonald resembled those northeast of Heard, also suggesting gas bubbles. We observed no bubbles on extremely limited towed camera data around McDonald; however, visibility was poor. The acoustic response of the plumes at different frequencies (120 kHz vs. 18 kHz), a technique used to classify water column scatterers, differed between HIMI, suggestiing dissimilar target size (bubble radii) distributions. Environmental context and temporal characteristics of the plumes differed between HIMI. Heard plumes were concentrated on flat, sediment rich plains, whereas around McDonald plumes emanated from sea knolls and mounds with hard volcanic seafloor. The Heard plumes were consistent temporally, while the McDonald plumes varied temporally possibly related to tides or subsurface processes. Our data and analyses suggest that HIMI acoustic plumes were likely caused by gas bubbles; however, the bubbles may originate from two or more distinct processes.

  9. Clonagem e purificação de fragmento da proteína capsidial de Banana streak OL virus Cloning and purification of Banana streak OL virus coat protein fragment

    Directory of Open Access Journals (Sweden)

    Ricardo Lombardi

    2010-08-01

    Full Text Available O objetivo deste trabalho foi clonar e induzir a expressão de fragmento da proteína capsidial de Banana streak OL virus (BSOLV-CP em Escherichia coli, bem como purificar a proteína recombinante obtida. Empregou-se um par de iniciadores específicos para amplificar, em PCR, um fragmento de aproximadamente 390 pb, da região codificadora da porção central da BSOLV-CP. O fragmento obtido foi clonado em vetor pGEM-T Easy, subclonado em vetor pQE-30 e transformado em células de E. coli M15 (pREP4 por choque térmico. A expressão da proteína foi induzida por tiogalactopiranosídeo de isopropila (IPTG, e a proteína recombinante BSOLV-rcCP de 14 kDa foi detectada em Western blot e Dot blot. A expressão da proteína BSOLV-rcCP abre novas possibilidades para a obtenção de antígenos para a produção de antissoros contra o BSOLV.The objective of this work was to clone and to induce the expression of a fragment of Banana streak OL virus coat protein (BSOLV-CP in Escherichia coli, as well as to purify the obtained recombinant protein. Two specific primers were used for the PCR-amplification of approximately 390-bp fragment of the codifying region of the BSOLV-CP central portion. The obtained fragment was cloned in pGEM-T Easy vector, subcloned in pQE-30 expression vector and transformed into competent E. coli M15 (pREP4 cells by heat shock. The protein expression was induced by isopropyl thiogalactopyranoside (IPTG and the 14-kDa BSOLV-rcCP recombinant protein was detected in Western and Dot blotting. The expression of the BSOLV-rcCP protein enables new approaches to the obtention of antigens for the antisera production against BSOLV.

  10. Transmission electron microscope CCD camera

    Science.gov (United States)

    Downing, Kenneth H.

    1999-01-01

    In order to improve the performance of a CCD camera on a high voltage electron microscope, an electron decelerator is inserted between the microscope column and the CCD. This arrangement optimizes the interaction of the electron beam with the scintillator of the CCD camera while retaining optimization of the microscope optics and of the interaction of the beam with the specimen. Changing the electron beam energy between the specimen and camera allows both to be optimized.

  11. Wavefront analysis for plenoptic camera imaging

    International Nuclear Information System (INIS)

    Luan Yin-Sen; Xu Bing; Yang Ping; Tang Guo-Mao

    2017-01-01

    The plenoptic camera is a single lens stereo camera which can retrieve the direction of light rays while detecting their intensity distribution. In this paper, to reveal more truths of plenoptic camera imaging, we present the wavefront analysis for the plenoptic camera imaging from the angle of physical optics but not from the ray tracing model of geometric optics. Specifically, the wavefront imaging model of a plenoptic camera is analyzed and simulated by scalar diffraction theory and the depth estimation is redescribed based on physical optics. We simulate a set of raw plenoptic images of an object scene, thereby validating the analysis and derivations and the difference between the imaging analysis methods based on geometric optics and physical optics are also shown in simulations. (paper)

  12. Homography-based multiple-camera person-tracking

    Science.gov (United States)

    Turk, Matthew R.

    2009-01-01

    Multiple video cameras are cheaply installed overlooking an area of interest. While computerized single-camera tracking is well-developed, multiple-camera tracking is a relatively new problem. The main multi-camera problem is to give the same tracking label to all projections of a real-world target. This is called the consistent labelling problem. Khan and Shah (2003) introduced a method to use field of view lines to perform multiple-camera tracking. The method creates inter-camera meta-target associations when objects enter at the scene edges. They also said that a plane-induced homography could be used for tracking, but this method was not well described. Their homography-based system would not work if targets use only one side of a camera to enter the scene. This paper overcomes this limitation and fully describes a practical homography-based tracker. A new method to find the feet feature is introduced. The method works especially well if the camera is tilted, when using the bottom centre of the target's bounding-box would produce inaccurate results. The new method is more accurate than the bounding-box method even when the camera is not tilted. Next, a method is presented that uses a series of corresponding point pairs "dropped" by oblivious, live human targets to find a plane-induced homography. The point pairs are created by tracking the feet locations of moving targets that were associated using the field of view line method. Finally, a homography-based multiple-camera tracking algorithm is introduced. Rules governing when to create the homography are specified. The algorithm ensures that homography-based tracking only starts after a non-degenerate homography is found. The method works when not all four field of view lines are discoverable; only one line needs to be found to use the algorithm. To initialize the system, the operator must specify pairs of overlapping cameras. Aside from that, the algorithm is fully automatic and uses the natural movement of

  13. Computing camera heading: A study

    Science.gov (United States)

    Zhang, John Jiaxiang

    2000-08-01

    An accurate estimate of the motion of a camera is a crucial first step for the 3D reconstruction of sites, objects, and buildings from video. Solutions to the camera heading problem can be readily applied to many areas, such as robotic navigation, surgical operation, video special effects, multimedia, and lately even in internet commerce. From image sequences of a real world scene, the problem is to calculate the directions of the camera translations. The presence of rotations makes this problem very hard. This is because rotations and translations can have similar effects on the images, and are thus hard to tell apart. However, the visual angles between the projection rays of point pairs are unaffected by rotations, and their changes over time contain sufficient information to determine the direction of camera translation. We developed a new formulation of the visual angle disparity approach, first introduced by Tomasi, to the camera heading problem. Our new derivation makes theoretical analysis possible. Most notably, a theorem is obtained that locates all possible singularities of the residual function for the underlying optimization problem. This allows identifying all computation trouble spots beforehand, and to design reliable and accurate computational optimization methods. A bootstrap-jackknife resampling method simultaneously reduces complexity and tolerates outliers well. Experiments with image sequences show accurate results when compared with the true camera motion as measured with mechanical devices.

  14. Dust visualisation in TJ-II with intensified visible fast cameras

    International Nuclear Information System (INIS)

    Cal, E. de la; Pablos, J. L. de; Carralero, D.; Hidalgo, C.

    2010-01-01

    A visible fast camera equipped with an image Intensifier and atomic line filters is used in TJ-II for spectroscopic dust observation. First results show characteristic features depending on filter and clearly differing from those without the filters as is usually done in existing experiments. Preliminary discussions of the observed results are presented. (Author) 5 refs.

  15. Dust visualisation in TJ-II with intensified visible Fast Cameras

    Energy Technology Data Exchange (ETDEWEB)

    Cal, E. de la; Pablos, J. L. de; Carralero, D.; Hidalgo, C.

    2010-10-21

    A visible fast camera equipped with an image Intensifier and atomic line filters is used in TJ-II for spectroscopic dust observation. First results show characteristic features depending on filter and clearly differing from those without the filters as is usually done in existing experiments. Preliminary discussions of the observed results are presented. (Author) 5 refs.

  16. Scintillation camera for high activity sources

    International Nuclear Information System (INIS)

    Arseneau, R.E.

    1978-01-01

    The invention described relates to a scintillation camera used for clinical medical diagnosis. Advanced recognition of many unacceptable pulses allows the scintillation camera to discard such pulses at an early stage in processing. This frees the camera to process a greater number of pulses of interest within a given period of time. Temporary buffer storage allows the camera to accommodate pulses received at a rate in excess of its maximum rated capability due to statistical fluctuations in the level of radioactivity of the radiation source measured. (U.K.)

  17. Decision about buying a gamma camera

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    A large part of the referral to a nuclear medicine department is usually for imaging studies. Sooner or later, the nuclear medicine specialist will be called upon to make a decision about when and what type of gamma camera to buy. There is no longer an option of choosing between a rectilinear scanner and a gamma camera as the former is virtually out of the market. The decision that one has to make is when to invest in a gamma camera, and then on what basis to select the gamma camera

  18. Decision about buying a gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Ganatra, R D

    1993-12-31

    A large part of the referral to a nuclear medicine department is usually for imaging studies. Sooner or later, the nuclear medicine specialist will be called upon to make a decision about when and what type of gamma camera to buy. There is no longer an option of choosing between a rectilinear scanner and a gamma camera as the former is virtually out of the market. The decision that one has to make is when to invest in a gamma camera, and then on what basis to select the gamma camera 1 tab., 1 fig

  19. Selective-imaging camera

    Science.gov (United States)

    Szu, Harold; Hsu, Charles; Landa, Joseph; Cha, Jae H.; Krapels, Keith A.

    2015-05-01

    How can we design cameras that image selectively in Full Electro-Magnetic (FEM) spectra? Without selective imaging, we cannot use, for example, ordinary tourist cameras to see through fire, smoke, or other obscurants contributing to creating a Visually Degraded Environment (VDE). This paper addresses a possible new design of selective-imaging cameras at firmware level. The design is consistent with physics of the irreversible thermodynamics of Boltzmann's molecular entropy. It enables imaging in appropriate FEM spectra for sensing through the VDE, and displaying in color spectra for Human Visual System (HVS). We sense within the spectra the largest entropy value of obscurants such as fire, smoke, etc. Then we apply a smart firmware implementation of Blind Sources Separation (BSS) to separate all entropy sources associated with specific Kelvin temperatures. Finally, we recompose the scene using specific RGB colors constrained by the HVS, by up/down shifting Planck spectra at each pixel and time.

  20. Video Chat with Multiple Cameras

    OpenAIRE

    MacCormick, John

    2012-01-01

    The dominant paradigm for video chat employs a single camera at each end of the conversation, but some conversations can be greatly enhanced by using multiple cameras at one or both ends. This paper provides the first rigorous investigation of multi-camera video chat, concentrating especially on the ability of users to switch between views at either end of the conversation. A user study of 23 individuals analyzes the advantages and disadvantages of permitting a user to switch between views at...

  1. Isolation and characterization of the mating type locus of Mycosphaerella fijiensis, the causal agent of black leaf streak disease of banana

    NARCIS (Netherlands)

    Conde, L.; Waalwijk, C.; Canto-Canché, B.B.; Kema, G.H.J.; Crous, P.W.; James, A.C.; Abeln, E.C.A.

    2007-01-01

    Idiomorphs mat1-1 and mat1-2 from Mycosphaerella fijiensis, the causal agent of black leaf streak disease of banana, were isolated. Degenerate oligos were used to amplify the HMG box of the mat1-2 idiomorph from M. fijiensis, showing homology with the HMG box of Mycosphaerella graminicola. Using a

  2. ERK inhibition promotes neuroectodermal precursor commitment by blocking self-renewal and primitive streak formation of the epiblast.

    Science.gov (United States)

    Yu, Yang; Wang, Xiaoxiao; Zhang, Xiaoxin; Zhai, Yanhua; Lu, Xukun; Ma, Haixia; Zhu, Kai; Zhao, Tongbiao; Jiao, Jianwei; Zhao, Zhen-Ao; Li, Lei

    2018-01-05

    Pluripotent stem cells hold great promise for regenerative medicine. However, before clinical application, reproducible protocols for pluripotent stem cell differentiation should be established. Extracellular signal-regulated protein kinase (ERK) signaling plays a central role for the self-renewal of epiblast stem cells (EpiSCs), but its role for subsequent germ layer differentiation is still ambiguous. We proposed that ERK could modulate differentiation of the epiblast. PD0325901 was used to inhibit ERK activation during the differentiation of embryonic stem cells and EpiSCs. Immunofluorescence, western blot analysis, real-time PCR and flow cytometry were used to detect germ layer markers and pathway activation. We demonstrate that the ERK phosphorylation level is lower in neuroectoderm of mouse E7.5 embryos than that in the primitive streak. ERK inhibition results in neural lineage commitment of epiblast. Mechanistically, PD0325901 abrogates the expression of primitive streak markers by β-catenin retention in the cytoplasm, and inhibits the expression of OCT4 and NANOG during EpiSC differentiation. Thus, EpiSCs differentiate into neuroectodermal lineage efficiently under PD0325901 treatment. These results suggest that neuroectoderm differentiation does not require extrinsic signals, supporting the default differentiation of neural lineage. We report that a single ERK inhibitor, PD0325901, can specify epiblasts and EpiSCs into neural-like cells, providing an efficient strategy for neural differentiation.

  3. Analyzer for gamma cameras diagnostic

    International Nuclear Information System (INIS)

    Oramas Polo, I.; Osorio Deliz, J. F.; Diaz Garcia, A.

    2013-01-01

    This research work was carried out to develop an analyzer for gamma cameras diagnostic. It is composed of an electronic system that includes hardware and software capabilities, and operates from the acquisition of the 4 head position signals of a gamma camera detector. The result is the spectrum of the energy delivered by nuclear radiation coming from the camera detector head. This system includes analog processing of position signals from the camera, digitization and the subsequent processing of the energy signal in a multichannel analyzer, sending data to a computer via a standard USB port and processing of data in a personal computer to obtain the final histogram. The circuits are composed of an analog processing board and a universal kit with micro controller and programmable gate array. (Author)

  4. Single Camera Calibration in 3D Vision

    Directory of Open Access Journals (Sweden)

    Caius SULIMAN

    2009-12-01

    Full Text Available Camera calibration is a necessary step in 3D vision in order to extract metric information from 2D images. A camera is considered to be calibrated when the parameters of the camera are known (i.e. principal distance, lens distorsion, focal length etc.. In this paper we deal with a single camera calibration method and with the help of this method we try to find the intrinsic and extrinsic camera parameters. The method was implemented with succes in the programming and simulation environment Matlab.

  5. Impact of New Camera Technologies on Discoveries in Cell Biology.

    Science.gov (United States)

    Stuurman, Nico; Vale, Ronald D

    2016-08-01

    New technologies can make previously invisible phenomena visible. Nowhere is this more obvious than in the field of light microscopy. Beginning with the observation of "animalcules" by Antonie van Leeuwenhoek, when he figured out how to achieve high magnification by shaping lenses, microscopy has advanced to this day by a continued march of discoveries driven by technical innovations. Recent advances in single-molecule-based technologies have achieved unprecedented resolution, and were the basis of the Nobel prize in Chemistry in 2014. In this article, we focus on developments in camera technologies and associated image processing that have been a major driver of technical innovations in light microscopy. We describe five types of developments in camera technology: video-based analog contrast enhancement, charge-coupled devices (CCDs), intensified sensors, electron multiplying gain, and scientific complementary metal-oxide-semiconductor cameras, which, together, have had major impacts in light microscopy. © 2016 Marine Biological Laboratory.

  6. RELATIVE AND ABSOLUTE CALIBRATION OF A MULTIHEAD CAMERA SYSTEM WITH OBLIQUE AND NADIR LOOKING CAMERAS FOR A UAS

    Directory of Open Access Journals (Sweden)

    F. Niemeyer

    2013-08-01

    Full Text Available Numerous unmanned aerial systems (UAS are currently flooding the market. For the most diverse applications UAVs are special designed and used. Micro and mini UAS (maximum take-off weight up to 5 kg are of particular interest, because legal restrictions are still manageable but also the payload capacities are sufficient for many imaging sensors. Currently a camera system with four oblique and one nadir looking cameras is under development at the Chair for Geodesy and Geoinformatics. The so-called "Four Vision" camera system was successfully built and tested in the air. A MD4-1000 UAS from microdrones is used as a carrier system. Light weight industrial cameras are used and controlled by a central computer. For further photogrammetric image processing, each individual camera, as well as all the cameras together have to be calibrated. This paper focuses on the determination of the relative orientation between the cameras with the „Australis“ software and will give an overview of the results and experiences of test flights.

  7. A camera specification for tendering purposes

    International Nuclear Information System (INIS)

    Lunt, M.J.; Davies, M.D.; Kenyon, N.G.

    1985-01-01

    A standardized document is described which is suitable for sending to companies which are being invited to tender for the supply of a gamma camera. The document refers to various features of the camera, the performance specification of the camera, maintenance details, price quotations for various options and delivery, installation and warranty details. (U.K.)

  8. Scientific Objectives of Small Carry-on Impactor (SCI) and Deployable Camera 3 Digital (DCAM3-D): Observation of an Ejecta Curtain and a Crater Formed on the Surface of Ryugu by an Artificial High-Velocity Impact

    Science.gov (United States)

    Arakawa, M.; Wada, K.; Saiki, T.; Kadono, T.; Takagi, Y.; Shirai, K.; Okamoto, C.; Yano, H.; Hayakawa, M.; Nakazawa, S.; Hirata, N.; Kobayashi, M.; Michel, P.; Jutzi, M.; Imamura, H.; Ogawa, K.; Sakatani, N.; Iijima, Y.; Honda, R.; Ishibashi, K.; Hayakawa, H.; Sawada, H.

    2017-07-01

    The Small Carry-on Impactor (SCI) equipped on Hayabusa2 was developed to produce an artificial impact crater on the primitive Near-Earth Asteroid (NEA) 162173 Ryugu (Ryugu) in order to explore the asteroid subsurface material unaffected by space weathering and thermal alteration by solar radiation. An exposed fresh surface by the impactor and/or the ejecta deposit excavated from the crater will be observed by remote sensing instruments, and a subsurface fresh sample of the asteroid will be collected there. The SCI impact experiment will be observed by a Deployable CAMera 3-D (DCAM3-D) at a distance of ˜1 km from the impact point, and the time evolution of the ejecta curtain will be observed by this camera to confirm the impact point on the asteroid surface. As a result of the observation of the ejecta curtain by DCAM3-D and the crater morphology by onboard cameras, the subsurface structure and the physical properties of the constituting materials will be derived from crater scaling laws. Moreover, the SCI experiment on Ryugu gives us a precious opportunity to clarify effects of microgravity on the cratering process and to validate numerical simulations and models of the cratering process.

  9. 16 CFR 501.1 - Camera film.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Camera film. 501.1 Section 501.1 Commercial... 500 § 501.1 Camera film. Camera film packaged and labeled for retail sale is exempt from the net... should be expressed, provided: (a) The net quantity of contents on packages of movie film and bulk still...

  10. SHOK—The First Russian Wide-Field Optical Camera in Space

    Science.gov (United States)

    Lipunov, V. M.; Gorbovskoy, E. S.; Kornilov, V. G.; Panasyuk, M. I.; Amelushkin, A. M.; Petrov, V. L.; Yashin, I. V.; Svertilov, S. I.; Vedenkin, N. N.

    2018-02-01

    Onboard the spacecraft Lomonosov is established two fast, fixed, very wide-field cameras SHOK. The main goal of this experiment is the observation of GRB optical emission before, synchronously, and after the gamma-ray emission. The field of view of each of the cameras is placed in the gamma-ray burst detection area of other devices located onboard the "Lomonosov" spacecraft. SHOK provides measurements of optical emissions with a magnitude limit of ˜ 9-10m on a single frame with an exposure of 0.2 seconds. The device is designed for continuous sky monitoring at optical wavelengths in the very wide field of view (1000 square degrees each camera), detection and localization of fast time-varying (transient) optical sources on the celestial sphere, including provisional and synchronous time recording of optical emissions from the gamma-ray burst error boxes, detected by the BDRG device and implemented by a control signal (alert trigger) from the BDRG. The Lomonosov spacecraft has two identical devices, SHOK1 and SHOK2. The core of each SHOK device is a fast-speed 11-Megapixel CCD. Each of the SHOK devices represents a monoblock, consisting of a node observations of optical emission, the electronics node, elements of the mechanical construction, and the body.

  11. Securing Embedded Smart Cameras with Trusted Computing

    Directory of Open Access Journals (Sweden)

    Winkler Thomas

    2011-01-01

    Full Text Available Camera systems are used in many applications including video surveillance for crime prevention and investigation, traffic monitoring on highways or building monitoring and automation. With the shift from analog towards digital systems, the capabilities of cameras are constantly increasing. Today's smart camera systems come with considerable computing power, large memory, and wired or wireless communication interfaces. With onboard image processing and analysis capabilities, cameras not only open new possibilities but also raise new challenges. Often overlooked are potential security issues of the camera system. The increasing amount of software running on the cameras turns them into attractive targets for attackers. Therefore, the protection of camera devices and delivered data is of critical importance. In this work we present an embedded camera prototype that uses Trusted Computing to provide security guarantees for streamed videos. With a hardware-based security solution, we ensure integrity, authenticity, and confidentiality of videos. Furthermore, we incorporate image timestamping, detection of platform reboots, and reporting of the system status. This work is not limited to theoretical considerations but also describes the implementation of a prototype system. Extensive evaluation results illustrate the practical feasibility of the approach.

  12. Principle of some gamma cameras (efficiencies, limitations, development)

    International Nuclear Information System (INIS)

    Allemand, R.; Bourdel, J.; Gariod, R.; Laval, M.; Levy, G.; Thomas, G.

    1975-01-01

    The quality of scintigraphic images is shown to depend on the efficiency of both the input collimator and the detector. Methods are described by which the quality of these images may be improved by adaptations to either the collimator (Fresnel zone camera, Compton effect camera) or the detector (Anger camera, image amplification camera). The Anger camera and image amplification camera are at present the two main instruments whereby acceptable space and energy resolutions may be obtained. A theoretical comparative study of their efficiencies is carried out, independently of their technological differences, after which the instruments designed or under study at the LETI are presented: these include the image amplification camera, the electron amplifier tube camera using a semi-conductor target CdTe and HgI 2 detector [fr

  13. Rochester scientist discovers new comet with Dark Energy Camera (DECam) at

    Science.gov (United States)

    Visiting Astronomers Guide Travel Information Questionnaire Vistor Support Questionaire Telescope Schedules time, seem to slowly jump from point to point. While searching our images one day, I was surprised to find a small streak of light with a tail, and like the Kuiper Belt objects it also jumped from point to

  14. Mesoscale circulation at the upper cloud level at middle latitudes from the imaging by Venus Monitoring Camera onboard Venus Express

    Science.gov (United States)

    Patsaeva, Marina; Ignatiev, Nikolay; Markiewicz, Wojciech; Khatuntsev, Igor; Titov, Dmitrij; Patsaev, Dmitry

    The Venus Monitoring Camera onboard ESA Venus Express spacecraft acquired a great number of UV images (365 nm) allowing us to track the motion of cloud features at the upper cloud layer of Venus. A digital method developed to analyze correlation functions between two UV images provided wind vector fields on the Venus day side (9-16 hours local time) from the equator to high latitudes. Sizes and regions for the correlation were chosen empirically, as a trade-off of sensitivity against noise immunity and vary from 10(°) x7.5(°) to 20(°) x10(°) depending on the grid step, making this method suitable to investigate the mesoscale circulation. Previously, the digital method was used for investigation of the circulation at low latitudes and provided good agreement with manual tracking of the motion of cloud patterns. Here we present first results obtained by this method for middle latitudes (25(°) S-75(°) S) on the basis of 270 orbits. Comparing obtained vector fields with images for certain orbits, we found a relationship between morphological patterns of the cloud cover at middle latitudes and parameters of the circulation. Elongated cloud features, so-called streaks, are typical for middle latitudes, and their orientation varies over wide range. The behavior of the vector field of velocities depends on the angle between the streak and latitude circles. In the middle latitudes the average angle of the flow deviation from the zonal direction is equal to -5.6(°) ± 1(°) (the sign “-“ means the poleward flow, the standard error is given). For certain orbits, this angle varies from -15.6(°) ± 1(°) to 1.4(°) ± 1(°) . In some regions at latitudes above 60(°) S the meridional wind is equatorward in the morning. The relationship between the cloud cover morphology and circulation peculiarity can be attributed to the motion of the Y-feature in the upper cloud layer due to the super-rotation of the atmosphere.

  15. Development of VNTR Markers to Assess Genetic Diversity of Mycosphaerella Fijiensis, the Causal Agent of Black Leaf Streak Disease in Bananas (Musa spp.)

    Science.gov (United States)

    Mycosphaerella fijiensis is the causal agent of black leaf streak (BLS) disease in bananas. This pathogen threatens global banana production as the main export cultivars are highly susceptible. As a consequence, commercial banana plantations must be protected chemically with fungicides; up to 40 app...

  16. Motorcycle detection and counting using stereo camera, IR camera, and microphone array

    Science.gov (United States)

    Ling, Bo; Gibson, David R. P.; Middleton, Dan

    2013-03-01

    Detection, classification, and characterization are the key to enhancing motorcycle safety, motorcycle operations and motorcycle travel estimation. Average motorcycle fatalities per Vehicle Mile Traveled (VMT) are currently estimated at 30 times those of auto fatalities. Although it has been an active research area for many years, motorcycle detection still remains a challenging task. Working with FHWA, we have developed a hybrid motorcycle detection and counting system using a suite of sensors including stereo camera, thermal IR camera and unidirectional microphone array. The IR thermal camera can capture the unique thermal signatures associated with the motorcycle's exhaust pipes that often show bright elongated blobs in IR images. The stereo camera in the system is used to detect the motorcyclist who can be easily windowed out in the stereo disparity map. If the motorcyclist is detected through his or her 3D body recognition, motorcycle is detected. Microphones are used to detect motorcycles that often produce low frequency acoustic signals. All three microphones in the microphone array are placed in strategic locations on the sensor platform to minimize the interferences of background noises from sources such as rain and wind. Field test results show that this hybrid motorcycle detection and counting system has an excellent performance.

  17. High speed photography of the plasma flow and the projectiles in the T.U.M. hypervelocity accelerator

    International Nuclear Information System (INIS)

    Igenbergs, E.; Kuczera, H.; Schroeder, B.

    1979-01-01

    The hypervelocity accelerator at the Technische Universitaet Muenchen, FRG, accelerates small projectiles (0.1 to 1.0 mm diameter) to velocities around 20 km/s. The photographic equipment consists of two Cordin single-frame image converter cameras and one TRW image converter camera with streak units and multiple-frame units. They are used for plasma flow diagnostics and the measurement of the position and the velocity of the projectiles. The single-frame cameras are triggered with a Laser light bar and the photographic measurement of the projectile velocity will be compared with Doppler-Radar. (author)

  18. Engineering task plan for Tanks 241-AN-103, 104, 105 color video camera systems

    International Nuclear Information System (INIS)

    Kohlman, E.H.

    1994-01-01

    This Engineering Task Plan (ETP) describes the design, fabrication, assembly, and installation of the video camera systems into the vapor space within tanks 241-AN-103, 104, and 105. The one camera remotely operated color video systems will be used to observe and record the activities within the vapor space. Activities may include but are not limited to core sampling, auger activities, crust layer examination, monitoring of equipment installation/removal, and any other activities. The objective of this task is to provide a single camera system in each of the tanks for the Flammable Gas Tank Safety Program

  19. Diagnostics for Z-pinch implosion experiments on PTS

    Energy Technology Data Exchange (ETDEWEB)

    Ren, X. D., E-mail: amosrxd@163.com; Huang, X. B., E-mail: amosrxd@163.com; Zhou, S. T., E-mail: amosrxd@163.com; Zhang, S. Q., E-mail: amosrxd@163.com; Dan, J. K., E-mail: amosrxd@163.com; Li, J., E-mail: amosrxd@163.com; Cai, H. C., E-mail: amosrxd@163.com; Wang, K. L., E-mail: amosrxd@163.com; Ouyang, K., E-mail: amosrxd@163.com; Xu, Q., E-mail: amosrxd@163.com; Duan, S. C., E-mail: amosrxd@163.com; Chen, G. H., E-mail: amosrxd@163.com; Wang, M., E-mail: amosrxd@163.com; Feng, S. P., E-mail: amosrxd@163.com; Yang, L. B., E-mail: amosrxd@163.com; Xie, W. P., E-mail: amosrxd@163.com; Deng, J. J., E-mail: amosrxd@163.com [Key Lab of Pulsed Power, Institute of Fluid Physics, CAEP, P.O. Box 919-108, Mianyang, Sichuan 621999 (China)

    2014-12-15

    The preliminary experiments of wire array implosion were performed on PTS, a 10 MA z-pinch driver with a 70 ns rise time. A set of diagnostics have been developed and fielded on PTS to study pinch physics and implosion dynamics of wire array. Radiated power measurement for soft x-rays was performed by multichannel filtered x-ray diode array, and flat spectral responses x-ray diode detector. Total x-ray yield was measured by a calibrated, unfiltered nickel bolometer which was also used to obtain pinch power. Multiple time-gated pinhole cameras were used to produce spatial-resolved images of x-ray self-emission from plasmas. Two time-integrated pinhole cameras were used respectively with 20-μm Be filter and with multilayer mirrors to record images produced by >1-keV and 277±5 eV self-emission. An optical streak camera was used to produce radial implosion trajectories, and an x-ray streak camera paired with a horizontal slit was used to record a continuous time-history of emission with one-dimensional spatial resolution. A frequency-doubled Nd:YAG laser (532 nm) was used to produce four frame laser shadowgraph images with 6 ns time interval. We will briefly describe each of these diagnostics and present some typical results from them.

  20. Effective data-domain noise and streak reduction for X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Zhi; Zamyatin, Alexander A. [Toshiba Medical Research Institute USA, Inc., Vernon Hills, IL (United States); Akino, Naruomi [Toshiba Medical System Corporation, Tokyo (Japan)

    2011-07-01

    Streaks and noise caused by photon starvation can seriously impair the diagnostic value of the CT imaging. Existing processing methods often have several parameters to tune. The parameters can be ad hoc to the data sets. Iterative methods can achieve better results, however, at the cost of more hardware resources or longer processing time. This paper reports a new scheme of adaptive Gaussian filtering, which is based on the diffusion-derived scale-space concept. In scale-space view, filtering by Gaussians of different sizes is similar to decompose the data into a sequence of scales. The scale measure, which is the variance of the filter, should be linearly related to the noise standard deviation instead of the variance of the noise. This is a fundamental deviation in the way of using filters. The new filter has only one parameter that remains stable once tuned. Singlepass processing can usually reach the desired results. (orig.)

  1. Performance Evaluation of Thermographic Cameras for Photogrammetric Measurements

    Science.gov (United States)

    Yastikli, N.; Guler, E.

    2013-05-01

    The aim of this research is the performance evaluation of the termographic cameras for possible use for photogrammetric documentation and deformation analyses caused by moisture and isolation problem of the historical and cultural heritage. To perform geometric calibration of the termographic camera, the 3D test object was designed with 77 control points which were distributed in different depths. For performance evaluation, Flir A320 termographic camera with 320 × 240 pixels and lens with 18 mm focal length was used. The Nikon D3X SLR digital camera with 6048 × 4032 pixels and lens with 20 mm focal length was used as reference for comparison. The size of pixel was 25 μm for the Flir A320 termographic camera and 6 μm for the Nikon D3X SLR digital camera. The digital images of the 3D test object were recorded with the Flir A320 termographic camera and Nikon D3X SLR digital camera and the image coordinate of the control points in the images were measured. The geometric calibration parameters, including the focal length, position of principal points, radial and tangential distortions were determined with introduced additional parameters in bundle block adjustments. The measurement of image coordinates and bundle block adjustments with additional parameters were performed using the PHIDIAS digital photogrammetric system. The bundle block adjustment was repeated with determined calibration parameter for both Flir A320 termographic camera and Nikon D3X SLR digital camera. The obtained standard deviation of measured image coordinates was 9.6 μm and 10.5 μm for Flir A320 termographic camera and 8.3 μm and 7.7 μm for Nikon D3X SLR digital camera. The obtained standard deviation of measured image points in Flir A320 termographic camera images almost same accuracy level with digital camera in comparison with 4 times bigger pixel size. The obtained results from this research, the interior geometry of the termographic cameras and lens distortion was modelled efficiently

  2. Location accuracy evaluation of lightning location systems using natural lightning flashes recorded by a network of high-speed cameras

    Science.gov (United States)

    Alves, J.; Saraiva, A. C. V.; Campos, L. Z. D. S.; Pinto, O., Jr.; Antunes, L.

    2014-12-01

    This work presents a method for the evaluation of location accuracy of all Lightning Location System (LLS) in operation in southeastern Brazil, using natural cloud-to-ground (CG) lightning flashes. This can be done through a multiple high-speed cameras network (RAMMER network) installed in the Paraiba Valley region - SP - Brazil. The RAMMER network (Automated Multi-camera Network for Monitoring and Study of Lightning) is composed by four high-speed cameras operating at 2,500 frames per second. Three stationary black-and-white (B&W) cameras were situated in the cities of São José dos Campos and Caçapava. A fourth color camera was mobile (installed in a car), but operated in a fixed location during the observation period, within the city of São José dos Campos. The average distance among cameras was 13 kilometers. Each RAMMER sensor position was determined so that the network can observe the same lightning flash from different angles and all recorded videos were GPS (Global Position System) time stamped, allowing comparisons of events between cameras and the LLS. The RAMMER sensor is basically composed by a computer, a Phantom high-speed camera version 9.1 and a GPS unit. The lightning cases analyzed in the present work were observed by at least two cameras, their position was visually triangulated and the results compared with BrasilDAT network, during the summer seasons of 2011/2012 and 2012/2013. The visual triangulation method is presented in details. The calibration procedure showed an accuracy of 9 meters between the accurate GPS position of the object triangulated and the result from the visual triangulation method. Lightning return stroke positions, estimated with the visual triangulation method, were compared with LLS locations. Differences between solutions were not greater than 1.8 km.

  3. Imaging capabilities of germanium gamma cameras

    International Nuclear Information System (INIS)

    Steidley, J.W.

    1977-01-01

    Quantitative methods of analysis based on the use of a computer simulation were developed and used to investigate the imaging capabilities of germanium gamma cameras. The main advantage of the computer simulation is that the inherent unknowns of clinical imaging procedures are removed from the investigation. The effects of patient scattered radiation were incorporated using a mathematical LSF model which was empirically developed and experimentally verified. Image modifying effects of patient motion, spatial distortions, and count rate capabilities were also included in the model. Spatial domain and frequency domain modeling techniques were developed and used in the simulation as required. The imaging capabilities of gamma cameras were assessed using low contrast lesion source distributions. The results showed that an improvement in energy resolution from 10% to 2% offers significant clinical advantages in terms of improved contrast, increased detectability, and reduced patient dose. The improvements are of greatest significance for small lesions at low contrast. The results of the computer simulation were also used to compare a design of a hypothetical germanium gamma camera with a state-of-the-art scintillation camera. The computer model performed a parametric analysis of the interrelated effects of inherent and technological limitations of gamma camera imaging. In particular, the trade-off between collimator resolution and collimator efficiency for detection of a given low contrast lesion was directly addressed. This trade-off is an inherent limitation of both gamma cameras. The image degrading effects of patient motion, camera spatial distortions, and low count rate were shown to modify the improvements due to better energy resolution. Thus, based on this research, the continued development of germanium cameras to the point of clinical demonstration is recommended

  4. Stereo Pinhole Camera: Assembly and experimental activities

    Directory of Open Access Journals (Sweden)

    Gilmário Barbosa Santos

    2015-05-01

    Full Text Available This work describes the assembling of a stereo pinhole camera for capturing stereo-pairs of images and proposes experimental activities with it. A pinhole camera can be as sophisticated as you want, or so simple that it could be handcrafted with practically recyclable materials. This paper describes the practical use of the pinhole camera throughout history and currently. Aspects of optics and geometry involved in the building of the stereo pinhole camera are presented with illustrations. Furthermore, experiments are proposed by using the images obtained by the camera for 3D visualization through a pair of anaglyph glasses, and the estimation of relative depth by triangulation is discussed.

  5. Space Debris and Observational Astronomy

    Science.gov (United States)

    Seitzer, Patrick

    2018-01-01

    Since the launch of Sputnik 1 in 1957, astronomers have faced an increasing number of artificial objects contaminating their images of the night sky. Currently almost 17000 objects larger than 10 cm are tracked and have current orbits in the public catalog. Active missions are only a small fraction of these objects. Most are inactive satellites, rocket bodies, and fragments of larger objects: all space debris. Several mega-constellations are planned which will increase this number by 20% or more in low Earth orbit (LEO). In terms of observational astronomy, this population of Earth orbiting objects has three implications: 1) the number of streaks and glints from spacecraft will only increase. There are some practical steps that can be taken to minimize the number of such streaks and glints in astronomical imaging data. 2) The risk to damage to orbiting astronomical telescopes will only increase, particularly those in LEO. 3) If you are working on a plan for an orbiting telescope project, then there are specific steps that must be taken to minimize space debris generation during the mission lifetime, and actions to safely dispose of the spacecraft at end of mission to prevent it from becoming space debris and a risk to other missions. These steps may involve sacrifices to mission performance and lifetime, but are essential in today's orbital environment.

  6. UV laser-driven shock-wave experiments at ultrahigh-pressures up to 5 TPa

    Energy Technology Data Exchange (ETDEWEB)

    Cottet, F.; Hallouin, M.; Romain, J.P. (GRECO ILM, Laboratoire d' Enegetique et Detonique, ENSMA, 86 - Poitiers (France)); Fabbro, R.; Faral, B. (GRECO ILM, Laboratoire de Physique des Milieux Ionises, Ecole Polytechnique, 91 - Palaiseau (France))

    1984-11-01

    Laser-driven shock pressures up to 5 TPa at 0.26 ..mu..m wavelenth have been evaluated from measurements of shock velocity through thin metallic foils (Al, Au, Cu) by streak camera records of shock luminosity at the near face of the foil.

  7. UV laser-driven shock-wave experiments at ultrahigh-pressures up to 5 TPa

    International Nuclear Information System (INIS)

    Cottet, F.; Hallouin, M.; Romain, J.P.; Fabbro, R.; Faral, B.

    1984-01-01

    Laser-driven shock pressures up to 5 TPa at 0.26 μm wavelenth have been evaluated from measurements of shock velocity through thin metallic foils (Al, Au, Cu) by streak camera records of shock luminosity at the near face of the foil

  8. First results from the TOPSAT camera

    Science.gov (United States)

    Greenway, Paul; Tosh, Ian; Morris, Nigel; Burton, Gary; Cawley, Steve

    2017-11-01

    The TopSat camera is a low cost remote sensing imager capable of producing 2.5 metre resolution panchromatic imagery, funded by the British National Space Centre's Mosaic programme. The instrument was designed and assembled at the Space Science & Technology Department of the CCLRC's Rutherford Appleton Laboratory (RAL) in the UK, and was launched on the 27th October 2005 from Plesetsk Cosmodrome in Northern Russia on a Kosmos-3M. The camera utilises an off-axis three mirror system, which has the advantages of excellent image quality over a wide field of view, combined with a compactness that makes its overall dimensions smaller than its focal length. Keeping the costs to a minimum has been a major design driver in the development of this camera. The camera is part of the TopSat mission, which is a collaboration between four UK organisations; QinetiQ, Surrey Satellite Technology Ltd (SSTL), RAL and Infoterra. Its objective is to demonstrate provision of rapid response high resolution imagery to fixed and mobile ground stations using a low cost minisatellite. The paper "Development of the TopSat Camera" presented by RAL at the 5th ICSO in 2004 described the opto-mechanical design, assembly, alignment and environmental test methods implemented. Now that the spacecraft is in orbit and successfully acquiring images, this paper presents the first results from the camera and makes an initial assessment of the camera's in-orbit performance.

  9. The Advanced Gamma-ray Imaging System (AGIS) - Camera Electronics Development

    Science.gov (United States)

    Tajima, Hiroyasu; Bechtol, K.; Buehler, R.; Buckley, J.; Byrum, K.; Drake, G.; Falcone, A.; Funk, S.; Hanna, D.; Horan, D.; Humensky, B.; Karlsson, N.; Kieda, D.; Konopelko, A.; Krawczynski, H.; Krennrich, F.; Mukherjee, R.; Ong, R.; Otte, N.; Quinn, J.; Schroedter, M.; Swordy, S.; Wagner, R.; Wakely, S.; Weinstein, A.; Williams, D.; Camera Working Group; AGIS Collaboration

    2010-03-01

    AGIS, a next-generation imaging atmospheric Cherenkov telescope (IACT) array, aims to achieve a sensitivity level of about one milliCrab for gamma-ray observations in the energy band of 50 GeV to 100 TeV. Achieving this level of performance will require on the order of 50 telescopes with perhaps as many as 1M total electronics channels. The larger scale of AGIS requires a very different approach from the currently operating IACTs, with lower-cost and lower-power electronics incorporated into camera modules designed for high reliability and easy maintenance. Here we present the concept and development status of the AGIS camera electronics.

  10. The Eye of the Camera

    NARCIS (Netherlands)

    van Rompay, Thomas Johannes Lucas; Vonk, Dorette J.; Fransen, M.L.

    2009-01-01

    This study addresses the effects of security cameras on prosocial behavior. Results from previous studies indicate that the presence of others can trigger helping behavior, arising from the need for approval of others. Extending these findings, the authors propose that security cameras can likewise

  11. In-air versus underwater comparison of 3D reconstruction accuracy using action sport cameras.

    Science.gov (United States)

    Bernardina, Gustavo R D; Cerveri, Pietro; Barros, Ricardo M L; Marins, João C B; Silvatti, Amanda P

    2017-01-25

    Action sport cameras (ASC) have achieved a large consensus for recreational purposes due to ongoing cost decrease, image resolution and frame rate increase, along with plug-and-play usability. Consequently, they have been recently considered for sport gesture studies and quantitative athletic performance evaluation. In this paper, we evaluated the potential of two ASCs (GoPro Hero3+) for in-air (laboratory) and underwater (swimming pool) three-dimensional (3D) motion analysis as a function of different camera setups involving the acquisition frequency, image resolution and field of view. This is motivated by the fact that in swimming, movement cycles are characterized by underwater and in-air phases what imposes the technical challenge of having a split volume configuration: an underwater measurement volume observed by underwater cameras and an in-air measurement volume observed by in-air cameras. The reconstruction of whole swimming cycles requires thus merging of simultaneous measurements acquired in both volumes. Characterizing and optimizing the instrumental errors of such a configuration makes mandatory the assessment of the instrumental errors of both volumes. In order to calibrate the camera stereo pair, black spherical markers placed on two calibration tools, used both in-air and underwater, and a two-step nonlinear optimization were exploited. The 3D reconstruction accuracy of testing markers and the repeatability of the estimated camera parameters accounted for system performance. For both environments, statistical tests were focused on the comparison of the different camera configurations. Then, each camera configuration was compared across the two environments. In all assessed resolutions, and in both environments, the reconstruction error (true distance between the two testing markers) was less than 3mm and the error related to the working volume diagonal was in the range of 1:2000 (3×1.3×1.5m 3 ) to 1:7000 (4.5×2.2×1.5m 3 ) in agreement with the

  12. LLE Review Quarterly Report (April-June 2001). Volume 87

    Energy Technology Data Exchange (ETDEWEB)

    Hinterman, Thomas H. [Univ. of Rochester, NY (United States). Lab. for Laser Energetics

    2001-06-01

    This volume of the LLE Review, covering April–June 2001, features ''A Self-Calibrating, Multichannel Streak Camera for Inertial Confinement Fusion Applications'' by Dr. W. R. Donaldson, R. Boni, R. L. Keck, and P. A. Jaanimagi. This article (p. 109) describes the 60-beam streak camera system used on OMEGA and focuses on the hardware and software calibration techniques that maximize its utility. The system can diagnose each of the beams on every target shot and can measure beam energies with 8% accuracy and timing at 7 ps rms. Beam-to-beam power variations of less than 5% can be detected. Other articles in this volume are: Evolution of Shell Nonuniformities Near Peak Compression of a Spherical Implosion; Multibeam Stimulated Brillouin Scattering from Hot Solid-Target Plasmas; Hot-Electron Effect in Superconductors and Is Applications for Radiation Sensors; and, Scaling Law for Marginal Ignition.

  13. Poster: A Software-Defined Multi-Camera Network

    OpenAIRE

    Chen, Po-Yen; Chen, Chien; Selvaraj, Parthiban; Claesen, Luc

    2016-01-01

    The widespread popularity of OpenFlow leads to a significant increase in the number of applications developed in SoftwareDefined Networking (SDN). In this work, we propose the architecture of a Software-Defined Multi-Camera Network consisting of small, flexible, economic, and programmable cameras which combine the functions of the processor, switch, and camera. A Software-Defined Multi-Camera Network can effectively reduce the overall network bandwidth and reduce a large amount of the Capex a...

  14. Gamma camera performance: technical assessment protocol

    Energy Technology Data Exchange (ETDEWEB)

    Bolster, A.A. [West Glasgow Hospitals NHS Trust, London (United Kingdom). Dept. of Clinical Physics; Waddington, W.A. [University College London Hospitals NHS Trust, London (United Kingdom). Inst. of Nuclear Medicine

    1996-12-31

    This protocol addresses the performance assessment of single and dual headed gamma cameras. No attempt is made to assess the performance of any associated computing systems. Evaluations are usually performed on a gamma camera commercially available within the United Kingdom and recently installed at a clinical site. In consultation with the manufacturer, GCAT selects the site and liaises with local staff to arrange a mutually convenient time for assessment. The manufacturer is encouraged to have a representative present during the evaluation. Three to four days are typically required for the evaluation team to perform the necessary measurements. When access time is limited, the team will modify the protocol to test the camera as thoroughly as possible. Data are acquired on the camera`s computer system and are subsequently transferred to the independent GCAT computer system for analysis. This transfer from site computer to the independent system is effected via a hardware interface and Interfile data transfer. (author).

  15. The Light Field Attachment: Turning a DSLR into a Light Field Camera Using a Low Budget Camera Ring

    KAUST Repository

    Wang, Yuwang

    2016-11-16

    We propose a concept for a lens attachment that turns a standard DSLR camera and lens into a light field camera. The attachment consists of 8 low-resolution, low-quality side cameras arranged around the central high-quality SLR lens. Unlike most existing light field camera architectures, this design provides a high-quality 2D image mode, while simultaneously enabling a new high-quality light field mode with a large camera baseline but little added weight, cost, or bulk compared with the base DSLR camera. From an algorithmic point of view, the high-quality light field mode is made possible by a new light field super-resolution method that first improves the spatial resolution and image quality of the side cameras and then interpolates additional views as needed. At the heart of this process is a super-resolution method that we call iterative Patch- And Depth-based Synthesis (iPADS), which combines patch-based and depth-based synthesis in a novel fashion. Experimental results obtained for both real captured data and synthetic data confirm that our method achieves substantial improvements in super-resolution for side-view images as well as the high-quality and view-coherent rendering of dense and high-resolution light fields.

  16. Object tracking using multiple camera video streams

    Science.gov (United States)

    Mehrubeoglu, Mehrube; Rojas, Diego; McLauchlan, Lifford

    2010-05-01

    Two synchronized cameras are utilized to obtain independent video streams to detect moving objects from two different viewing angles. The video frames are directly correlated in time. Moving objects in image frames from the two cameras are identified and tagged for tracking. One advantage of such a system involves overcoming effects of occlusions that could result in an object in partial or full view in one camera, when the same object is fully visible in another camera. Object registration is achieved by determining the location of common features in the moving object across simultaneous frames. Perspective differences are adjusted. Combining information from images from multiple cameras increases robustness of the tracking process. Motion tracking is achieved by determining anomalies caused by the objects' movement across frames in time in each and the combined video information. The path of each object is determined heuristically. Accuracy of detection is dependent on the speed of the object as well as variations in direction of motion. Fast cameras increase accuracy but limit the speed and complexity of the algorithm. Such an imaging system has applications in traffic analysis, surveillance and security, as well as object modeling from multi-view images. The system can easily be expanded by increasing the number of cameras such that there is an overlap between the scenes from at least two cameras in proximity. An object can then be tracked long distances or across multiple cameras continuously, applicable, for example, in wireless sensor networks for surveillance or navigation.

  17. PERFORMANCE EVALUATION OF THERMOGRAPHIC CAMERAS FOR PHOTOGRAMMETRIC MEASUREMENTS

    Directory of Open Access Journals (Sweden)

    N. Yastikli

    2013-05-01

    Full Text Available The aim of this research is the performance evaluation of the termographic cameras for possible use for photogrammetric documentation and deformation analyses caused by moisture and isolation problem of the historical and cultural heritage. To perform geometric calibration of the termographic camera, the 3D test object was designed with 77 control points which were distributed in different depths. For performance evaluation, Flir A320 termographic camera with 320 × 240 pixels and lens with 18 mm focal length was used. The Nikon D3X SLR digital camera with 6048 × 4032 pixels and lens with 20 mm focal length was used as reference for comparison. The size of pixel was 25 μm for the Flir A320 termographic camera and 6 μm for the Nikon D3X SLR digital camera. The digital images of the 3D test object were recorded with the Flir A320 termographic camera and Nikon D3X SLR digital camera and the image coordinate of the control points in the images were measured. The geometric calibration parameters, including the focal length, position of principal points, radial and tangential distortions were determined with introduced additional parameters in bundle block adjustments. The measurement of image coordinates and bundle block adjustments with additional parameters were performed using the PHIDIAS digital photogrammetric system. The bundle block adjustment was repeated with determined calibration parameter for both Flir A320 termographic camera and Nikon D3X SLR digital camera. The obtained standard deviation of measured image coordinates was 9.6 μm and 10.5 μm for Flir A320 termographic camera and 8.3 μm and 7.7 μm for Nikon D3X SLR digital camera. The obtained standard deviation of measured image points in Flir A320 termographic camera images almost same accuracy level with digital camera in comparison with 4 times bigger pixel size. The obtained results from this research, the interior geometry of the termographic cameras and lens distortion was

  18. Comparison of myocardial perfusion imaging between the new high-speed gamma camera and the standard anger camera

    International Nuclear Information System (INIS)

    Tanaka, Hirokazu; Chikamori, Taishiro; Hida, Satoshi

    2013-01-01

    Cadmium-zinc-telluride (CZT) solid-state detectors have been recently introduced into the field of myocardial perfusion imaging. The aim of this study was to prospectively compare the diagnostic performance of the CZT high-speed gamma camera (Discovery NM 530c) with that of the standard 3-head gamma camera in the same group of patients. The study group consisted of 150 consecutive patients who underwent a 1-day stress-rest 99m Tc-sestamibi or tetrofosmin imaging protocol. Image acquisition was performed first on a standard gamma camera with a 15-min scan time each for stress and for rest. All scans were immediately repeated on a CZT camera with a 5-min scan time for stress and a 3-min scan time for rest, using list mode. The correlations between the CZT camera and the standard camera for perfusion and function analyses were strong within narrow Bland-Altman limits of agreement. Using list mode analysis, image quality for stress was rated as good or excellent in 97% of the 3-min scans, and in 100% of the ≥4-min scans. For CZT scans at rest, similarly, image quality was rated as good or excellent in 94% of the 1-min scans, and in 100% of the ≥2-min scans. The novel CZT camera provides excellent image quality, which is equivalent to standard myocardial single-photon emission computed tomography, despite a short scan time of less than half of the standard time. (author)

  19. High resolution RGB color line scan camera

    Science.gov (United States)

    Lynch, Theodore E.; Huettig, Fred

    1998-04-01

    A color line scan camera family which is available with either 6000, 8000 or 10000 pixels/color channel, utilizes off-the-shelf lenses, interfaces with currently available frame grabbers, includes on-board pixel by pixel offset correction, and is configurable and controllable via RS232 serial port for computer controlled or stand alone operation is described in this paper. This line scan camera is based on an available 8000 element monochrome line scan camera designed by AOA for OEM use. The new color version includes improvements such as better packaging and additional user features which make the camera easier to use. The heart of the camera is a tri-linear CCD sensor with on-chip color balancing for maximum accuracy and pinned photodiodes for low lag response. Each color channel is digitized to 12 bits and all three channels are multiplexed together so that the resulting camera output video is either a 12 or 8 bit data stream at a rate of up to 24Megpixels/sec. Conversion from 12 to 8 bit, or user-defined gamma, is accomplished by on board user-defined video look up tables. The camera has two user-selectable operating modes; lows speed, high sensitivity mode or high speed, reduced sensitivity mode. The intended uses of the camera include industrial inspection, digital archiving, document scanning, and graphic arts applications.

  20. An Open Standard for Camera Trap Data

    Directory of Open Access Journals (Sweden)

    Tavis Forrester

    2016-12-01

    Full Text Available Camera traps that capture photos of animals are a valuable tool for monitoring biodiversity. The use of camera traps is rapidly increasing and there is an urgent need for standardization to facilitate data management, reporting and data sharing. Here we offer the Camera Trap Metadata Standard as an open data standard for storing and sharing camera trap data, developed by experts from a variety of organizations. The standard captures information necessary to share data between projects and offers a foundation for collecting the more detailed data needed for advanced analysis. The data standard captures information about study design, the type of camera used, and the location and species names for all detections in a standardized way. This information is critical for accurately assessing results from individual camera trapping projects and for combining data from multiple studies for meta-analysis. This data standard is an important step in aligning camera trapping surveys with best practices in data-intensive science. Ecology is moving rapidly into the realm of big data, and central data repositories are becoming a critical tool and are emerging for camera trap data. This data standard will help researchers standardize data terms, align past data to new repositories, and provide a framework for utilizing data across repositories and research projects to advance animal ecology and conservation.

  1. Camera network video summarization

    Science.gov (United States)

    Panda, Rameswar; Roy-Chowdhury, Amit K.

    2017-05-01

    Networks of vision sensors are deployed in many settings, ranging from security needs to disaster response to environmental monitoring. Many of these setups have hundreds of cameras and tens of thousands of hours of video. The difficulty of analyzing such a massive volume of video data is apparent whenever there is an incident that requires foraging through vast video archives to identify events of interest. As a result, video summarization, that automatically extract a brief yet informative summary of these videos, has attracted intense attention in the recent years. Much progress has been made in developing a variety of ways to summarize a single video in form of a key sequence or video skim. However, generating a summary from a set of videos captured in a multi-camera network still remains as a novel and largely under-addressed problem. In this paper, with the aim of summarizing videos in a camera network, we introduce a novel representative selection approach via joint embedding and capped l21-norm minimization. The objective function is two-fold. The first is to capture the structural relationships of data points in a camera network via an embedding, which helps in characterizing the outliers and also in extracting a diverse set of representatives. The second is to use a capped l21-norm to model the sparsity and to suppress the influence of data outliers in representative selection. We propose to jointly optimize both of the objectives, such that embedding can not only characterize the structure, but also indicate the requirements of sparse representative selection. Extensive experiments on standard multi-camera datasets well demonstrate the efficacy of our method over state-of-the-art methods.

  2. The use of a portable gamma camera for preoperative lymphatic mapping: a comparison with a conventional gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Vidal-Sicart, Sergi; Paredes, Pilar [Hospital Clinic Barcelona, Nuclear Medicine Department (CDIC), Barcelona (Spain); Institut d' Investigacio Biomedica Agusti Pi Sunyer (IDIBAPS), Barcelona (Spain); Vermeeren, Lenka; Valdes-Olmos, Renato A. [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital (NKI-AVL), Nuclear Medicine Department, Amsterdam (Netherlands); Sola, Oriol [Hospital Clinic Barcelona, Nuclear Medicine Department (CDIC), Barcelona (Spain)

    2011-04-15

    Planar lymphoscintigraphy is routinely used for preoperative sentinel node visualization, but large gamma cameras are not always available. We evaluated the reproducibility of lymphatic mapping with a smaller and portable gamma camera. In two centres, 52 patients with breast cancer received preoperative lymphoscintigraphy with a conventional gamma camera with a field of view of 40 x 40 cm. Static anterior and lateral images were performed at 15 min, 2 h and 4 h after injection of the radiotracer ({sup 99m}Tc-nanocolloid). At 2 h after injection, anterior and oblique images were also performed with a portable gamma camera (Sentinella, Oncovision) positioned to obtain a field of view of 20 x 20 cm. Visualization of lymphatic drainage on conventional images and images with the portable device were compared for number of nodes depicted, their intensity and localization of sentinel nodes. The images performed with the conventional gamma camera depicted sentinel nodes in 94%, while the portable gamma camera showed drainage in 73%. There was however no significant difference in visualization between the two devices when a lead shield was used to mask the injection area in 43 patients (95 vs 88%, p = 0.25). Second-echelon nodes were visualized in 62% of the patients with the conventional gamma camera and in 29% of the cases with the portable gamma camera. Preoperative imaging with a portable gamma camera fitted with a pinhole collimator to obtain a field of view of 20 x 20 cm is able to depict sentinel nodes in 88% of the cases, if a lead shield is used to mask the injection site. This device may be useful in centres without the possibility to perform a preoperative image. (orig.)

  3. The use of a portable gamma camera for preoperative lymphatic mapping: a comparison with a conventional gamma camera

    International Nuclear Information System (INIS)

    Vidal-Sicart, Sergi; Paredes, Pilar; Vermeeren, Lenka; Valdes-Olmos, Renato A.; Sola, Oriol

    2011-01-01

    Planar lymphoscintigraphy is routinely used for preoperative sentinel node visualization, but large gamma cameras are not always available. We evaluated the reproducibility of lymphatic mapping with a smaller and portable gamma camera. In two centres, 52 patients with breast cancer received preoperative lymphoscintigraphy with a conventional gamma camera with a field of view of 40 x 40 cm. Static anterior and lateral images were performed at 15 min, 2 h and 4 h after injection of the radiotracer ( 99m Tc-nanocolloid). At 2 h after injection, anterior and oblique images were also performed with a portable gamma camera (Sentinella, Oncovision) positioned to obtain a field of view of 20 x 20 cm. Visualization of lymphatic drainage on conventional images and images with the portable device were compared for number of nodes depicted, their intensity and localization of sentinel nodes. The images performed with the conventional gamma camera depicted sentinel nodes in 94%, while the portable gamma camera showed drainage in 73%. There was however no significant difference in visualization between the two devices when a lead shield was used to mask the injection area in 43 patients (95 vs 88%, p = 0.25). Second-echelon nodes were visualized in 62% of the patients with the conventional gamma camera and in 29% of the cases with the portable gamma camera. Preoperative imaging with a portable gamma camera fitted with a pinhole collimator to obtain a field of view of 20 x 20 cm is able to depict sentinel nodes in 88% of the cases, if a lead shield is used to mask the injection site. This device may be useful in centres without the possibility to perform a preoperative image. (orig.)

  4. People identification for domestic non-overlapping RGB-D camera networks

    NARCIS (Netherlands)

    Takac, B.; Rauterberg, G.W.M.; Català, A.; Chen, W.

    2015-01-01

    The ability to identify the specific person in a home camera network is very relevant for healthcare applications where humans need to be observed daily in their living environment. The appearance based people identification in a domestic environment has many similarities with the problem of

  5. Video Sharing System Based on Wi-Fi Camera

    OpenAIRE

    Qidi Lin; Hewei Yu; Jinbin Huang; Weile Liang

    2015-01-01

    This paper introduces a video sharing platform based on WiFi, which consists of camera, mobile phone and PC server. This platform can receive wireless signal from the camera and show the live video on the mobile phone captured by camera. In addition, it is able to send commands to camera and control the camera's holder to rotate. The platform can be applied to interactive teaching and dangerous area's monitoring and so on. Testing results show that the platform can share ...

  6. EDICAM (Event Detection Intelligent Camera)

    Energy Technology Data Exchange (ETDEWEB)

    Zoletnik, S. [Wigner RCP RMI, EURATOM Association, Budapest (Hungary); Szabolics, T., E-mail: szabolics.tamas@wigner.mta.hu [Wigner RCP RMI, EURATOM Association, Budapest (Hungary); Kocsis, G.; Szepesi, T.; Dunai, D. [Wigner RCP RMI, EURATOM Association, Budapest (Hungary)

    2013-10-15

    Highlights: ► We present EDICAM's hardware modules. ► We present EDICAM's main design concepts. ► This paper will describe EDICAM firmware architecture. ► Operation principles description. ► Further developments. -- Abstract: A new type of fast framing camera has been developed for fusion applications by the Wigner Research Centre for Physics during the last few years. A new concept was designed for intelligent event driven imaging which is capable of focusing image readout to Regions of Interests (ROIs) where and when predefined events occur. At present these events mean intensity changes and external triggers but in the future more sophisticated methods might also be defined. The camera provides 444 Hz frame rate at full resolution of 1280 × 1024 pixels, but monitoring of smaller ROIs can be done in the 1–116 kHz range even during exposure of the full image. Keeping space limitations and the harsh environment in mind the camera is divided into a small Sensor Module and a processing card interconnected by a fast 10 Gbit optical link. This camera hardware has been used for passive monitoring of the plasma in different devices for example at ASDEX Upgrade and COMPASS with the first version of its firmware. The new firmware and software package is now available and ready for testing the new event processing features. This paper will present the operation principle and features of the Event Detection Intelligent Camera (EDICAM). The device is intended to be the central element in the 10-camera monitoring system of the Wendelstein 7-X stellarator.

  7. Development and evaluation of a portable CZT coded aperture gamma-camera

    Energy Technology Data Exchange (ETDEWEB)

    Montemont, G.; Monnet, O.; Stanchina, S.; Maingault, L.; Verger, L. [CEA, LETI, Minatec Campus, Univ. Grenoble Alpes, 38054 Grenoble, (France); Carrel, F.; Lemaire, H.; Schoepff, V. [CEA, LIST, 91191 Gif-sur-Yvette, (France); Ferrand, G.; Lalleman, A.-S. [CEA, DAM, DIF, 91297 Arpajon, (France)

    2015-07-01

    We present the design and the evaluation of a CdZnTe (CZT) based gamma camera using a coded aperture mask. This camera, based on a 8 cm{sup 3} detection module, is small enough to be portable and battery-powered (4 kg weight and 4 W power dissipation). As the detector has spectral capabilities, the gamma camera allows isotope identification and colored imaging, by affecting one color channel to each identified isotope. As all data processing is done at real time, the user can directly observe the outcome of an acquisition and can immediately react to what he sees. We first present the architecture of the system, how the detector works, and its performances. After, we focus on the imaging technique used and its strengths and limitations. Finally, results concerning sensitivity, spatial resolution, field of view and multi-isotope imaging are shown and discussed. (authors)

  8. Development and evaluation of a portable CZT coded aperture gamma-camera

    International Nuclear Information System (INIS)

    Montemont, G.; Monnet, O.; Stanchina, S.; Maingault, L.; Verger, L.; Carrel, F.; Lemaire, H.; Schoepff, V.; Ferrand, G.; Lalleman, A.-S.

    2015-01-01

    We present the design and the evaluation of a CdZnTe (CZT) based gamma camera using a coded aperture mask. This camera, based on a 8 cm 3 detection module, is small enough to be portable and battery-powered (4 kg weight and 4 W power dissipation). As the detector has spectral capabilities, the gamma camera allows isotope identification and colored imaging, by affecting one color channel to each identified isotope. As all data processing is done at real time, the user can directly observe the outcome of an acquisition and can immediately react to what he sees. We first present the architecture of the system, how the detector works, and its performances. After, we focus on the imaging technique used and its strengths and limitations. Finally, results concerning sensitivity, spatial resolution, field of view and multi-isotope imaging are shown and discussed. (authors)

  9. Performance characterization of UV science cameras developed for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP)

    Science.gov (United States)

    Champey, P.; Kobayashi, K.; Winebarger, A.; Cirtain, J.; Hyde, D.; Robertson, B.; Beabout, D.; Beabout, B.; Stewart, M.

    2014-07-01

    The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-α and to detect the Hanle effect in the line core. Due to the nature of Lyman-α polarizationin the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1% in the line core. CLASP is a dual-beam spectro-polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1% polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. The CLASP cameras were designed to operate with ≤ 10 e-/pixel/second dark current, ≤ 25 e- read noise, a gain of 2.0 +- 0.5 and ≤ 1.0% residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; dark current, read noise, camera gain and residual non-linearity.

  10. An Open Standard for Camera Trap Data

    NARCIS (Netherlands)

    Forrester, Tavis; O'Brien, Tim; Fegraus, Eric; Jansen, P.A.; Palmer, Jonathan; Kays, Roland; Ahumada, Jorge; Stern, Beth; McShea, William

    2016-01-01

    Camera traps that capture photos of animals are a valuable tool for monitoring biodiversity. The use of camera traps is rapidly increasing and there is an urgent need for standardization to facilitate data management, reporting and data sharing. Here we offer the Camera Trap Metadata Standard as an

  11. IR-camera methods for automotive brake system studies

    Science.gov (United States)

    Dinwiddie, Ralph B.; Lee, Kwangjin

    1998-03-01

    Automotive brake systems are energy conversion devices that convert kinetic energy into heat energy. Several mechanisms, mostly related to noise and vibration problems, can occur during brake operation and are often related to non-uniform temperature distribution on the brake disk. These problems are of significant cost to the industry and are a quality concern to automotive companies and brake system vendors. One such problem is thermo-elastic instabilities in brake system. During the occurrence of these instabilities several localized hot spots will form around the circumferential direction of the brake disk. The temperature distribution and the time dependence of these hot spots, a critical factor in analyzing this problem and in developing a fundamental understanding of this phenomenon, were recorded. Other modes of non-uniform temperature distributions which include hot banding and extreme localized heating were also observed. All of these modes of non-uniform temperature distributions were observed on automotive brake systems using a high speed IR camera operating in snap-shot mode. The camera was synchronized with the rotation of the brake disk so that the time evolution of hot regions could be studied. This paper discusses the experimental approach in detail.

  12. Polarizing aperture stereoscopic cinema camera

    Science.gov (United States)

    Lipton, Lenny

    2012-07-01

    The art of stereoscopic cinematography has been held back because of the lack of a convenient way to reduce the stereo camera lenses' interaxial to less than the distance between the eyes. This article describes a unified stereoscopic camera and lens design that allows for varying the interaxial separation to small values using a unique electro-optical polarizing aperture design for imaging left and right perspective views onto a large single digital sensor, the size of the standard 35 mm frame, with the means to select left and right image information. Even with the added stereoscopic capability, the appearance of existing camera bodies will be unaltered.

  13. Control system for gamma camera

    International Nuclear Information System (INIS)

    Miller, D.W.

    1977-01-01

    An improved gamma camera arrangement is described which utilizing a solid state detector, formed of high purity germanium. the central arrangement of the camera operates to effect the carrying out of a trapezoidal filtering operation over antisymmetrically summed spatial signals through gated integration procedures utilizing idealized integrating intervals. By simultaneously carrying out peak energy evaluation of the input signals, a desirable control over pulse pile-up phenomena is achieved. Additionally, through the use of the time derivative of incoming pulse or signal energy information to initially enable the control system, a low level information evaluation is provided serving to enhance the signal processing efficiency of the camera

  14. New design for the UCO/Lick Observatory CCD guide camera

    Science.gov (United States)

    Wei, Mingzhi; Stover, Richard J.

    1996-03-01

    A new CCD based field acquisition and telescope guiding camera is being designed and built at UCO/Lick Observatory. Our goal is a camera which is fully computer controllable, compact in size, versatile enough to provide a wide variety of image acquisition modes, and able to operate with a wide variety of CCD detectors. The camera will improve our remote-observing capabilities since it will be easy to control the camera and obtain images over the Observatory computer network. To achieve the desired level of operating flexibility, the design incorporates state-of-the-art technologies such as high density, high speed programmable logic devices and non-volatile static memory. Various types of CCDs can be used in this system without major modification of the hardware or software. Though fully computer controllable, the camera can be operated as a stand-alone unit with most operating parameters set locally. A stand-alone display subsystem is also available. A thermoelectric device is used to cool the CCD to about -45c. Integration times can be varied over a range of 0.1 to 1000 seconds. High speed pixel skipping in both horizontal and vertical directions allows us to quickly access a selected subarea of the detector. Three different read out speeds allow the astronomer to select between high-speed/high-noise and low-speed/low-noise operation. On- chip pixel binning and MPP operation are also selectable options. This system can provide automatic sky level measurement and subtraction to accommodate dynamically changing background levels.

  15. Scintillating camera

    International Nuclear Information System (INIS)

    Vlasbloem, H.

    1976-01-01

    The invention relates to a scintillating camera and in particular to an apparatus for determining the position coordinates of a light pulse emitting point on the anode of an image intensifier tube which forms part of a scintillating camera, comprising at least three photomultipliers which are positioned to receive light emitted by the anode screen on their photocathodes, circuit means for processing the output voltages of the photomultipliers to derive voltages that are representative of the position coordinates; a pulse-height discriminator circuit adapted to be fed with the sum voltage of the output voltages of the photomultipliers for gating the output of the processing circuit when the amplitude of the sum voltage of the output voltages of the photomultipliers lies in a predetermined amplitude range, and means for compensating the distortion introduced in the image on the anode screen

  16. Design of an experimental four-camera setup for enhanced 3D surface reconstruction in microsurgery

    Directory of Open Access Journals (Sweden)

    Marzi Christian

    2017-09-01

    Full Text Available Future fully digital surgical visualization systems enable a wide range of new options. Caused by optomechanical limitations a main disadvantage of today’s surgical microscopes is their incapability of providing arbitrary perspectives to more than two observers. In a fully digital microscopic system, multiple arbitrary views can be generated from a 3D reconstruction. Modern surgical microscopes allow replacing the eyepieces by cameras in order to record stereoscopic videos. A reconstruction from these videos can only contain the amount of detail the recording camera system gathers from the scene. Therefore, covered surfaces can result in a faulty reconstruction for deviating stereoscopic perspectives. By adding cameras recording the object from different angles, additional information of the scene is acquired, allowing to improve the reconstruction. Our approach is to use a fixed four-camera setup as a front-end system to capture enhanced 3D topography of a pseudo-surgical scene. This experimental setup would provide images for the reconstruction algorithms and generation of multiple observing stereo perspectives. The concept of the designed setup is based on the common main objective (CMO principle of current surgical microscopes. These systems are well established and optically mature. Furthermore, the CMO principle allows a more compact design and a lowered effort in calibration than cameras with separate optics. Behind the CMO four pupils separate the four channels which are recorded by one camera each. The designed system captures an area of approximately 28mm × 28mm with four cameras. Thus, allowing to process images of 6 different stereo perspectives. In order to verify the setup, it is modelled in silico. It can be used in further studies to test algorithms for 3D reconstruction from up to four perspectives and provide information about the impact of additionally recorded perspectives on the enhancement of a reconstruction.

  17. The "All Sky Camera Network"

    Science.gov (United States)

    Caldwell, Andy

    2005-01-01

    In 2001, the "All Sky Camera Network" came to life as an outreach program to connect the Denver Museum of Nature and Science (DMNS) exhibit "Space Odyssey" with Colorado schools. The network is comprised of cameras placed strategically at schools throughout Colorado to capture fireballs--rare events that produce meteorites.…

  18. Initial laboratory evaluation of color video cameras: Phase 2

    Energy Technology Data Exchange (ETDEWEB)

    Terry, P.L.

    1993-07-01

    Sandia National Laboratories has considerable experience with monochrome video cameras used in alarm assessment video systems. Most of these systems, used for perimeter protection, were designed to classify rather than to identify intruders. The monochrome cameras were selected over color cameras because they have greater sensitivity and resolution. There is a growing interest in the identification function of security video systems for both access control and insider protection. Because color camera technology is rapidly changing and because color information is useful for identification purposes, Sandia National Laboratories has established an on-going program to evaluate the newest color solid-state cameras. Phase One of the Sandia program resulted in the SAND91-2579/1 report titled: Initial Laboratory Evaluation of Color Video Cameras. The report briefly discusses imager chips, color cameras, and monitors, describes the camera selection, details traditional test parameters and procedures, and gives the results reached by evaluating 12 cameras. Here, in Phase Two of the report, we tested 6 additional cameras using traditional methods. In addition, all 18 cameras were tested by newly developed methods. This Phase 2 report details those newly developed test parameters and procedures, and evaluates the results.

  19. High resolution soft X-Ray spectrometer with 5-picosecond time-resolution for laser-produced plasma diagnostics

    International Nuclear Information System (INIS)

    Mexmain, J.M.; Bourgade, J.L.; Louis-Jacquet, M.; Mascureau, J. de; Sauneuf, R.; Schwob, J.L.

    1987-01-01

    A new XUV spectrometer designed to have a time-resolution of 3 ps and a spectral resolution of 0.1 A is described. It is basically a modified version of a Schwob-Fraenkel spectrometer, which is coupled to a new ultrafast electronic streak camera

  20. Development of compact Compton camera for 3D image reconstruction of radioactive contamination

    Science.gov (United States)

    Sato, Y.; Terasaka, Y.; Ozawa, S.; Nakamura Miyamura, H.; Kaburagi, M.; Tanifuji, Y.; Kawabata, K.; Torii, T.

    2017-11-01

    The Fukushima Daiichi Nuclear Power Station (FDNPS), operated by Tokyo Electric Power Company Holdings, Inc., went into meltdown after the large tsunami caused by the Great East Japan Earthquake of March 11, 2011. Very large amounts of radionuclides were released from the damaged plant. Radiation distribution measurements inside FDNPS buildings are indispensable to execute decommissioning tasks in the reactor buildings. We have developed a compact Compton camera to measure the distribution of radioactive contamination inside the FDNPS buildings three-dimensionally (3D). The total weight of the Compton camera is lower than 1.0 kg. The gamma-ray sensor of the Compton camera employs Ce-doped GAGG (Gd3Al2Ga3O12) scintillators coupled with a multi-pixel photon counter. Angular correction of the detection efficiency of the Compton camera was conducted. Moreover, we developed a 3D back-projection method using the multi-angle data measured with the Compton camera. We successfully observed 3D radiation images resulting from the two 137Cs radioactive sources, and the image of the 9.2 MBq source appeared stronger than that of the 2.7 MBq source.

  1. Movement-based Interaction in Camera Spaces

    DEFF Research Database (Denmark)

    Eriksson, Eva; Riisgaard Hansen, Thomas; Lykke-Olesen, Andreas

    2006-01-01

    In this paper we present three concepts that address movement-based interaction using camera tracking. Based on our work with several movement-based projects we present four selected applications, and use these applications to leverage our discussion, and to describe our three main concepts space......, relations, and feedback. We see these as central for describing and analysing movement-based systems using camera tracking and we show how these three concepts can be used to analyse other camera tracking applications....

  2. Photogrammetric Applications of Immersive Video Cameras

    OpenAIRE

    Kwiatek, K.; Tokarczyk, R.

    2014-01-01

    The paper investigates immersive videography and its application in close-range photogrammetry. Immersive video involves the capture of a live-action scene that presents a 360° field of view. It is recorded simultaneously by multiple cameras or microlenses, where the principal point of each camera is offset from the rotating axis of the device. This issue causes problems when stitching together individual frames of video separated from particular cameras, however there are ways to ov...

  3. 21 CFR 886.1120 - Opthalmic camera.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1120 Opthalmic camera. (a) Identification. An ophthalmic camera is an AC-powered device intended to take photographs of the eye and the surrounding area...

  4. On the accuracy potential of focused plenoptic camera range determination in long distance operation

    Science.gov (United States)

    Sardemann, Hannes; Maas, Hans-Gerd

    2016-04-01

    Plenoptic cameras have found increasing interest in optical 3D measurement techniques in recent years. While their basic principle is 100 years old, the development in digital photography, micro-lens fabrication technology and computer hardware has boosted the development and lead to several commercially available ready-to-use cameras. Beyond their popular option of a posteriori image focusing or total focus image generation, their basic ability of generating 3D information from single camera imagery depicts a very beneficial option for certain applications. The paper will first present some fundamentals on the design and history of plenoptic cameras and will describe depth determination from plenoptic camera image data. It will then present an analysis of the depth determination accuracy potential of plenoptic cameras. While most research on plenoptic camera accuracy so far has focused on close range applications, we will focus on mid and long ranges of up to 100 m. This range is especially relevant, if plenoptic cameras are discussed as potential mono-sensorial range imaging devices in (semi-)autonomous cars or in mobile robotics. The results show the expected deterioration of depth measurement accuracy with depth. At depths of 30-100 m, which may be considered typical in autonomous driving, depth errors in the order of 3% (with peaks up to 10-13 m) were obtained from processing small point clusters on an imaged target. Outliers much higher than these values were observed in single point analysis, stressing the necessity of spatial or spatio-temporal filtering of the plenoptic camera depth measurements. Despite these obviously large errors, a plenoptic camera may nevertheless be considered a valid option for the application fields of real-time robotics like autonomous driving or unmanned aerial and underwater vehicles, where the accuracy requirements decrease with distance.

  5. Approximate Learning and Inference for Tracking with Non-overlapping Cameras

    NARCIS (Netherlands)

    Zajdel, W.; Kröse, B.; Hamza, M.H.

    2003-01-01

    Tracking with multiple cameras requires partitioning of ob servations from various sensors into trajectories. In this paper we assume that the observations are generated by a hidden, stochastic 'partition' process and propose a hidden Markov model (HMM) as a generative model for the data. The state

  6. Variable number of tandem repeat markers in the genome sequence of Mycosphaerella fijiensis, the causal agent of black leaf streak disease of banana (Musa spp)

    NARCIS (Netherlands)

    Garcia, S.A.L.; Lee, van der T.A.J.; Ferreira, C.F.; Lintel Hekkert, te B.; Zapater, M.F.; Goodwin, S.B.; Guzmán, M.; Kema, G.H.J.; Souza, M.T.

    2010-01-01

    ABSTRACT. We searched the genome of Mycosphaerella fijiensis for molecular markers that would allow population genetics analysis of this plant pathogen. M. fijiensis, the causal agent of banana leaf streak disease, also known as black Sigatoka, is the most devastating pathogen attacking bananas

  7. System Architecture of the Dark Energy Survey Camera Readout Electronics

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, Theresa; /FERMILAB; Ballester, Otger; Cardiel-Sas, Laia; Castilla, Javier; /Barcelona, IFAE; Chappa, Steve; /Fermilab; de Vicente, Juan; /Madrid, CIEMAT; Holm, Scott; Huffman, Dave; Kozlovsky, Mark; /Fermilab; Martinez, Gustavo; /Madrid, CIEMAT; Moore, Todd; /Madrid, CIEMAT /Fermilab /Illinois U., Urbana /Fermilab

    2010-05-27

    The Dark Energy Survey makes use of a new camera, the Dark Energy Camera (DECam). DECam will be installed in the Blanco 4M telescope at Cerro Tololo Inter-American Observatory (CTIO). DECam is presently under construction and is expected to be ready for observations in the fall of 2011. The focal plane will make use of 62 2Kx4K and 12 2kx2k fully depleted Charge-Coupled Devices (CCDs) for guiding, alignment and focus. This paper will describe design considerations of the system; including, the entire signal path used to read out the CCDs, the development of a custom crate and backplane, the overall grounding scheme and early results of system tests.

  8. Space and time resolved observations of plasma dynamics in a compressional gas embedded Z-pinch

    International Nuclear Information System (INIS)

    Soto, L.; Chuaqui, H.; Favre, M.; Saavedra, R.; Wyndham, E.; Aliaga-Rossel, R.; Mitchell, I.

    1996-01-01

    Recent experiments in a gas embedded compressional Z-pinch are presented. The experiments have been carried out in H 2 at 1/3 atm, using a pulse power generator capable of delivering a dl/dt > 10 12 A/s. The pinch is initiated by a focused laser pulse, which is coaxial with a cylindrical DC microdischarge. This configuration results in double column pinch at early times, which at current rise evolves into a gas embedded compressional Z-pinch. Diagnostics used are Rogowski coil, single frame holographic interferometry, and holographic shadowgraphy, visible streak camera images from which current, density, line density, pinch radius and plasma motion are obtained. The pinch is characterized by a maximum on axis density which is much higher than the expected value from the filling pressure, with a Bennett temperature of 40 eV at 130 kA. The results shown confirm the high degree of compression achievable with the composite preionization scheme. (author). 4 figs., 5 refs

  9. Observation of the dynamic movement of fragmentations by high-speed camera and high-speed video

    Science.gov (United States)

    Suk, Chul-Gi; Ogata, Yuji; Wada, Yuji; Katsuyama, Kunihisa

    1995-05-01

    The experiments of blastings using mortal concrete blocks and model concrete columns were carried out in order to obtain technical information on fragmentation caused by the blasting demolition. The dimensions of mortal concrete blocks were 1,000 X 1,000 X 1,000 mm. Six kinds of experimental blastings were carried out using mortal concrete blocks. In these experiments precision detonators and No. 6 electric detonators with 10 cm detonating fuse were used and discussed the control of fragmentation. As the results of experiment it was clear that the flying distance of fragmentation can be controlled using a precise blasting system. The reinforced concrete model columns for typical apartment houses in Japan were applied to the experiments. The dimension of concrete test column was 800 X 800 X 2400 mm and buried 400 mm in the ground. The specified design strength of the concrete was 210 kgf/cm2. These columns were exploded by the blasting with internal loading of dynamite. The fragmentation were observed by two kinds of high speed camera with 500 and 2000 FPS and a high speed video with 400 FPS. As one of the results in the experiments, the velocity of fragmentation, blasted 330 g of explosive with the minimum resisting length of 0.32 m, was measured as much as about 40 m/s.

  10. Architectural Design Document for Camera Models

    DEFF Research Database (Denmark)

    Thuesen, Gøsta

    1998-01-01

    Architecture of camera simulator models and data interface for the Maneuvering of Inspection/Servicing Vehicle (MIV) study.......Architecture of camera simulator models and data interface for the Maneuvering of Inspection/Servicing Vehicle (MIV) study....

  11. Hidden cameras everything you need to know about covert recording, undercover cameras and secret filming

    CERN Document Server

    Plomin, Joe

    2016-01-01

    Providing authoritative information on the practicalities of using hidden cameras to expose abuse or wrongdoing, this book is vital reading for anyone who may use or encounter secret filming. It gives specific advice on using phones or covert cameras and unravels the complex legal and ethical issues that need to be considered.

  12. Performance Characterization of UV Science Cameras Developed for the Chromospheric Lyman-Alpha Spectro-Polarimeter

    Science.gov (United States)

    Champey, P.; Kobayashi, K.; Winebarger, A.; Cirtain, J.; Hyde, D.; Robertson, B.; Beabout, D.; Beabout, B.; Stewart, M.

    2014-01-01

    The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-alpha and to detect the Hanle effect in the line core. Due to the nature of Lyman-alpha polarization in the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1 percent in the line core. CLASP is a dual-beam spectro-polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1 percent polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. Coating the e2v CCD57-10 512x512 detectors with Lumogen-E coating allows for a relatively high (30 percent) quantum efficiency at the Lyman-alpha line. The CLASP cameras were designed to operate with 10 e-/pixel/second dark current, 25 e- read noise, a gain of 2.0 +/- 0.5 and 1.0 percent residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; dark current, read noise, camera gain and residual non-linearity.

  13. A preliminary study to estimate contact rates between free-roaming domestic dogs using novel miniature cameras.

    Directory of Open Access Journals (Sweden)

    Courtenay B Bombara

    Full Text Available Information on contacts between individuals within a population is crucial to inform disease control strategies, via parameterisation of disease spread models. In this study we investigated the use of dog-borne video cameras-in conjunction with global positioning systems (GPS loggers-to both characterise dog-to-dog contacts and to estimate contact rates. We customized miniaturised video cameras, enclosed within 3D-printed plastic cases, and attached these to nylon dog collars. Using two 3400 mAh NCR lithium Li-ion batteries, cameras could record a maximum of 22 hr of continuous video footage. Together with a GPS logger, collars were attached to six free roaming domestic dogs (FRDDs in two remote Indigenous communities in northern Australia. We recorded a total of 97 hr of video footage, ranging from 4.5 to 22 hr (mean 19.1 per dog, and observed a wide range of social behaviours. The majority (69% of all observed interactions between community dogs involved direct physical contact. Direct contact behaviours included sniffing, licking, mouthing and play fighting. No contacts appeared to be aggressive, however multiple teeth baring incidents were observed during play fights. We identified a total of 153 contacts-equating to 8 to 147 contacts per dog per 24 hr-from the videos of the five dogs with camera data that could be analysed. These contacts were attributed to 42 unique dogs (range 1 to 19 per video which could be identified (based on colour patterns and markings. Most dog activity was observed in urban (houses and roads environments, but contacts were more common in bushland and beach environments. A variety of foraging behaviours were observed, included scavenging through rubbish and rolling on dead animal carcasses. Identified food consumed included chicken, raw bones, animal carcasses, rubbish, grass and cheese. For characterising contacts between FRDD, several benefits of analysing videos compared to GPS fixes alone were identified in

  14. Long wavelength infrared camera (LWIRC): a 10 micron camera for the Keck Telescope

    Energy Technology Data Exchange (ETDEWEB)

    Wishnow, E.H.; Danchi, W.C.; Tuthill, P.; Wurtz, R.; Jernigan, J.G.; Arens, J.F.

    1998-05-01

    The Long Wavelength Infrared Camera (LWIRC) is a facility instrument for the Keck Observatory designed to operate at the f/25 forward Cassegrain focus of the Keck I telescope. The camera operates over the wavelength band 7-13 {micro}m using ZnSe transmissive optics. A set of filters, a circular variable filter (CVF), and a mid-infrared polarizer are available, as are three plate scales: 0.05``, 0.10``, 0.21`` per pixel. The camera focal plane array and optics are cooled using liquid helium. The system has been refurbished with a 128 x 128 pixel Si:As detector array. The electronics readout system used to clock the array is compatible with both the hardware and software of the other Keck infrared instruments NIRC and LWS. A new pre-amplifier/A-D converter has been designed and constructed which decreases greatly the system susceptibility to noise.

  15. Using a laser scanning camera for reactor inspection

    International Nuclear Information System (INIS)

    Armour, I.A.; Adrain, R.S.; Klewe, R.C.

    1984-01-01

    Inspection of nuclear reactors is normally carried out using TV or film cameras. There are, however, several areas where these cameras show considerable shortcomings. To overcome these difficulties, laser scanning cameras have been developed. This type of camera can be used for general visual inspection as well as the provision of high resolution video images with high ratio on and off-axis zoom capability. In this paper, we outline the construction and operation of a laser scanning camera and give examples of how it has been used in various power stations, and indicate future potential developments. (author)

  16. An alternative scanning protocol to eliminate perivenous streak artifacts in thoracic spiral computed tomography. The usefulness of ankle vein contrast injection

    International Nuclear Information System (INIS)

    Hara, Masaki; Ogino, Hiroyuki; Itoh, Masato; Ohba, Satoru; Andoh, Keiichi; Kitase, Masanori; Goodman, P.C.

    2001-01-01

    The purpose of this study was to eliminate perivenous streak artifact from contrast-enhanced thoracic spiral CT using superficial ankle vein injection (ankle vein method). Forty-four consecutive inpatients had thoracic spiral CT following ankle vein method and were compared to 30 patients who had conventional antecubital vein injection. Non-ionic 300 mg/mL contrast material were injected at 1-1.5 mL/sec with a power injector. Twenty mL of normal saline was injected immediately thereafter as a flushing bolus. Qualitative scores of perivenous artifact (1 to 5=extensive) and vascular enhancement (1 to 5=excellent) were recorded. Complications were investigated clinically. The mean score of perivenous artifact was 1 with the ankle vein method and 4.4 with the conventional method (P<.0001). Scores of pulmonary artery opacification were almost equal (4.2 and 4.5 respectively, P=.11). No complications were observed. The ankle vein method is an effective method to prevent perivenous artifact during thoracic spiral CT. (author)

  17. Search for atmospheric holes with the Viking cameras

    International Nuclear Information System (INIS)

    Frank, L.A.; Sigwarth, J.B.; Craven, J.D.

    1989-01-01

    Images taken with the two ultraviolet cameras on board the Viking spacecraft were examined for evidence of transient decreases of Earth's ultraviolet dayglow. Comparison of near-limb observations of dayglow intensities with those at smaller angles to the nadir with the camera sensitive to OI 130.4 nm emissions supports the existence of transient decreases in the near-nadir dayglow. However, the amount of near-nadir imaging is severely limited and only several significant events are found. More decisive confirmation of the existence of such transient decreases must await a larger survey from another spacecraft. The diameters of these regions as detected with Viking are ∼50 to 100 km. Occurrence frequencies, intensity decreases, and dimensions for these clusters of darkened pixels are similar to those previously reported for such events, or atmospheric holes, as seen in images of the ultraviolet dayglow with Dynamics Explorer 1

  18. Septa design for a prostate specific PET camera

    International Nuclear Information System (INIS)

    Qi, Jinyi; Huber, Jennifer S.; Huesman, Ronald H.; Moses, William W.; Derenzo, Stephen E.; Budinger, Thomas F.

    2003-01-01

    The recent development of new prostate tracers has motivated us to build a low cost PET camera optimized to image the prostate. Coincidence imaging of positron emitters is achieved using a pair of external curved detector banks. The bottom bank is fixed below the patient bed, and the top bank moves upward for patient access and downward for maximum sensitivity. In this paper, we study the design of septa for the prostate camera using Monte Carlo simulations. The system performance is measured by the detectability of a prostate lesion. We have studied 17 septa configurations. The results show that the design of septa has a large impact on the lesion detection at a given activity concentration. Significant differences are also observed between the lesion detectability and the conventional noise equivalent count (NEC) performance, indicating that the NEC is not appropriate for the detection task

  19. Qualification Tests of Micro-camera Modules for Space Applications

    Science.gov (United States)

    Kimura, Shinichi; Miyasaka, Akira

    Visual capability is very important for space-based activities, for which small, low-cost space cameras are desired. Although cameras for terrestrial applications are continually being improved, little progress has been made on cameras used in space, which must be extremely robust to withstand harsh environments. This study focuses on commercial off-the-shelf (COTS) CMOS digital cameras because they are very small and are based on an established mass-market technology. Radiation and ultrahigh-vacuum tests were conducted on a small COTS camera that weighs less than 100 mg (including optics). This paper presents the results of the qualification tests for COTS cameras and for a small, low-cost COTS-based space camera.

  20. Effectiveness of several dosage formula of oil and nano emulsion of citronella against vascular streak dieback (VSD) disease on cocoa

    Science.gov (United States)

    Noveriza, R.; Trisno, J.; Rahma, H.; Yuliani, S.; Reflin; Martinius

    2018-02-01

    The disease of Vascular streak dieback (VSD) is a deadly disease of cocoa plants, because it attacks the vascular tissue of cocoa at growing point of the plant. In West Sumatra the disease was first reported in 2015 with an incidence of disease range 58.82% - 100% and an intensity of disease range 24.29% - 44.7%. The purpose of this study was to examine the effectiveness of dosage application of oil formula and nano emulsion of citronella formula against Vascular streak dieback (VSD) disease on cocoa plants in West Sumatra (in Padang Pariaman District and Limapuluh Kota District). The results showed that the percentage of VSD disease attacks in both testing sites was 100%. The oil and nano emulsion of citronella formulas can reduce the intensity of VSD disease on cocoa plants in West Sumatra, particularly in Padang Pariaman District and Limapuluh Kota District. The reduction of VSD intensity in Padang Pariaman district ranged from 8.32 to 21.13%; while in Limapuluh Kota district ranged from 4.33 to 11.80%. The nano emulsion of citronella formulation is effective to suppress the intensity of VSD disease on cocoa plants at doses 0.1% (≥ 30% of effectiveness level).