WorldWideScience

Sample records for straight tubular bandaging

  1. Inkjet printed wireless smart bandage

    KAUST Repository

    Farooqui, Muhammad Fahad; Shamim, Atif

    2016-01-01

    Chronic wounds affect millions of patients around the world and requires a major portion of health care budget for treatment. In this article, we present an unprecedented low cost continuous wireless monitoring system, realized through inkjet printing on a standard bandage strip, which can send early warnings as well as record long term wound progression data. The smart bandage can communicate upto a distance of 60 m when worn on the body.

  2. Inkjet printed wireless smart bandage

    KAUST Repository

    Farooqui, Muhammad Fahad

    2016-12-19

    Chronic wounds affect millions of patients around the world and requires a major portion of health care budget for treatment. In this article, we present an unprecedented low cost continuous wireless monitoring system, realized through inkjet printing on a standard bandage strip, which can send early warnings as well as record long term wound progression data. The smart bandage can communicate upto a distance of 60 m when worn on the body.

  3. A compression bandage improves local infiltration analgesia in total knee arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Lasse; Husted, Henrik; Otte, Niels Kristian Stahl Kri

    2008-01-01

    .2% ropivacaine infiltration analgesia were randomized to receive a compression or a non-compression bandage, and pain was assessed at rest and with mobilization at regular intervals for 24 h postoperatively. RESULTS: Pain at rest, during flexion, or on straight leg lift was lower for the first 8 h in patients...

  4. Impact of multilayered compression bandages on sub-bandage interface pressure: a model.

    Science.gov (United States)

    Al Khaburi, J; Nelson, E A; Hutchinson, J; Dehghani-Sanij, A A

    2011-03-01

    Multi-component medical compression bandages are widely used to treat venous leg ulcers. The sub-bandage interface pressures induced by individual components of the multi-component compression bandage systems are not always simply additive. Current models to explain compression bandage performance do not take account of the increase in leg circumference when each bandage is applied, and this may account for the difference between predicted and actual pressures. To calculate the interface pressure when a multi-component compression bandage system is applied to a leg. Use thick wall cylinder theory to estimate the sub-bandage pressure over the leg when a multi-component compression bandage is applied to a leg. A mathematical model was developed based on thick cylinder theory to include bandage thickness in the calculation of the interface pressure in multi-component compression systems. In multi-component compression systems, the interface pressure corresponds to the sum of the pressures applied by individual bandage layers. However, the change in the limb diameter caused by additional bandage layers should be considered in the calculation. Adding the interface pressure produced by single components without considering the bandage thickness will result in an overestimate of the overall interface pressure produced by the multi-component compression systems. At the ankle (circumference 25 cm) this error can be 19.2% or even more in the case of four components bandaging systems. Bandage thickness should be considered when calculating the pressure applied using multi-component compression systems.

  5. Use of customised pressure-guided elastic bandages to improve efficacy of compression bandaging for venous ulcers.

    Science.gov (United States)

    Sermsathanasawadi, Nuttawut; Chatjaturapat, Choedpong; Pianchareonsin, Rattana; Puangpunngam, Nattawut; Wongwanit, Chumpol; Chinsakchai, Khamin; Ruangsetakit, Chanean; Mutirangura, Pramook

    2017-08-01

    Compression bandaging is a major treatment of chronic venous ulcers. Its efficacy depends on the applied pressure, which is dependent on the skill of the individual applying the bandage. To improve the quality of bandaging by reducing the variability in compression bandage interface pressures, we changed elastic bandages into a customised version by marking them with circular ink stamps, applied when the stretch achieves an interface pressure between 35 and 45 mmHg. Repeated applications by 20 residents of the customised bandage and non-marked bandage to one smaller and one larger leg were evaluated by measuring the sub-bandage pressure. The results demonstrated that the target pressure range is more often attained with the customised bandage compared with the non-marked bandage. The customised bandage improved the efficacy of compression bandaging for venous ulcers, with optimal sub-bandage pressure. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  6. Customizing elastic pressure bandages for reuse to a predetermined, sub-bandage pressure: A randomized controlled trial.

    Science.gov (United States)

    Sermsathanasawadi, Nuttawut; Tarapongpun, Tanakorn; Pianchareonsin, Rattana; Puangpunngam, Nattawut; Wongwanit, Chumpol; Chinsakchai, Khamin; Mutirangura, Pramook; Ruangsetakit, Chanean

    2017-01-01

    Objective A randomized clinical trial was performed to compare the effectiveness of unmarked bandages and customized bandages with visual markers in reproducing the desired sub-bandage pressure during self-bandaging by patients. Method Ninety patients were randomly allocated to two groups ("customized bandages" and "unmarked bandages") and asked to perform self-bandaging three times. The achievement of a pressure between 35 and 45 mmHg in at least two of the three attempts was defined as adequate quality. Results Adequate quality was achieved by 33.0% when applying the unmarked bandages, and 60.0% when applying the customized bandages ( p = 0.02). Use of the customized bandage and previous experience of bandaging were independent predictors for the achievement of the predetermined sub-bandage pressure ( p = 0.005 and p = 0.021, respectively). Conclusion Customized bandages may achieve predetermined sub-bandage pressures more closely than standard, unmarked, compression bandages. Clinical trials registration ClinicalTrials.gov (NCT02729688). Effectiveness of a Pressure Indicator Guided and a Conventional Bandaging in Treatment of Venous Leg Ulcer. https://clinicaltrials.gov/ct2/show/NCT02729688.

  7. Tubular combustion

    CERN Document Server

    Ishizuka, Satoru

    2014-01-01

    Tubular combustors are cylindrical tubes where flame ignition and propagation occur in a spatially confined, highly controlled environment, in a nearly flat, elongated geometry. This allows for some unique advantages where extremely even heat dispersion is required over a large surface while still maintaining fuel efficiency. Tubular combustors also allow for easy flexibility in type of fuel source, allowing for quick changeover to meet various needs and changing fuel pricing. This new addition to the MP sustainable energy series will provide the most up-to-date research on tubular combustion--some of it only now coming out of private proprietary protection. Plentiful examples of current applications along with a good explanation of background theory will offer readers an invaluable guide on this promising energy technology. Highlights include: * An introduction to the theory of tubular flames * The "how to" of maintaining stability of tubular flames through continuous combustion * Examples of both small-scal...

  8. Design and development of novel bandages for compression therapy.

    Science.gov (United States)

    Rajendran, Subbiyan; Anand, Subhash

    2003-03-01

    During the past few years there have been increasing concerns relating to the performance of bandages, especially their pressure distribution properties for the treatment of venous leg ulcers. This is because compression therapy is a complex system and requires two or multi-layer bandages, and the performance properties of each layer differs from other layers. The widely accepted sustained graduated compression mainly depends on the uniform pressure distribution of different layers of bandages, in which textile fibres and bandage structures play a major role. This article examines how the fibres, fibre blends and structures influence the absorption and pressure distribution properties of bandages. It is hoped that the research findings will help medical professionals, especially nurses, to gain an insight into the development of bandages. A total of 12 padding bandages have been produced using various fibres and fibre blends. A new technique that would facilitate good resilience and cushioning properties, higher and more uniform pressure distribution and enhanced water absorption and retention was adopted during the production. It has been found that the properties of developed padding bandages, which include uniform pressure distribution around the leg, are superior to existing commercial bandages and possess a number of additional properties required to meet the criteria stipulated for an ideal padding bandage. Results have indicated that none of the mostly used commercial padding bandages provide the required uniform pressure distribution around the limb.

  9. Interface pressure is affected by slippage of bandages at thigh.

    Science.gov (United States)

    Miyazaki, K; Hirai, M; Koyama, A; Iwata, H; Ohashi, M; Ota, A

    2012-12-01

    Very little is known about how compression bandages lose interface pressure. We hypothesized that the loss of interface pressure is correlated with the slippage of the bandages, and studied the interface pressure and slippage of three bandages over 8 hours. Twenty-Seven legs from 27 healthy volunteers were bandaged with short stretch bandages (SS), cohesive short stretch bandages (CS), and long stretch bandages (LS). Pressure sensors were placed above the ankle (B1), below the knee (D), and mid thigh (F). Interface pressures in a sitting position were recorded at the beginning, and 4 and 8 hours later. In 17 legs, the pressure sensor sites were marked, and their heights were measured on standing upright. SS and CS lost interface pressure quickly, but LS maintained pressure better than SS and CS at all sites. There was no pressure difference between SS and CS at the lower leg. However, CS maintained pressure better than SS at the mid thigh (44.6% vs. 54.4% pressure loss at 8 hours, respectively. P=0.037). There was a tendency toward less slippage with CS than SS at the mid thigh. In CS and LS, there was a linear correlation between the slippage of bandages and the interface pressure at the mid thigh (P pressure may be affected by the slippage of bandages at the thigh, but not at the lower leg. Cohesive short stretch bandages may exert their beneficial impact at the thigh.

  10. Expansive cements for the manufacture of the concrete protective bandages

    Science.gov (United States)

    Yakymechko, Yaroslav; Voloshynets, Vladyslav

    2017-12-01

    One of the promising directions of the use of expansive cements is making the protective bandages for the maintenance of pipelines. Bandages expansive application of the compositions of the pipeline reinforce the damaged area and reduce stress due to compressive stress in the cylindrical area. Such requirements are best suited for expansive compositions obtained from portland cement and modified quicklime. The article presents the results of expansive cements based on quick lime in order to implement protective bandages pipelines.

  11. CONVENTIONAL MASTOID BANDAGE FOLLOWING OTOLOGICAL SURGERIES - IS IT NECESSARY?

    Directory of Open Access Journals (Sweden)

    Sumit

    2016-03-01

    Full Text Available BACKGROUND Mastoid pressure bandage post otological surgeries are usually applied to prevent post-operative wound haematoma and proper wound cover. Many other materials (e.g. Micropore, Dynaplast are used instead of conventional bandage. AIMS The purpose of this study was to assess whether compressive head bandages are necessary after ear surgery to prevent complications such as haematoma or wound infection. METHODS A hospital based study of 50 patients (30 males & 20 females who underwent tympano-mastoidectomies, were selectively applied different types of mastoid bandages, following which their advantages & disadvantages post-operatively (early & late were studied. RESULTS Out of 50 cases, in which 15 cases were applied conventional mastoid bandage resulted in 4 complications (26.66%. Whereas out of 20 cases of Dynaplast bandage, only 2 showed minor complications (10% with only pain during removal of this bandage. Out of 15 cases where Micropore was used as bandage, only 2 showed up with minor complications (13.33% with only pain during removal of Micropore.

  12. A bandage contact lens prevents extrusion of ocular contents.

    Science.gov (United States)

    Ramjiani, Vipul; Fearnley, Thomas; Tan, Jennifer

    2016-02-01

    A 76 year old male presents with a corneal perforation in a phthisical eye. Definitive treatment in the form of an evisceration was delayed by 38 days. During this period a bandage contact lens prevented extrusion of ocular contents through an enlarging corneal perforation. This case demonstrates that a bandage contact lens can be effective in the immediate management of large corneal perforations whilst awaiting urgent definitive treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Distal renal tubular acidosis

    Science.gov (United States)

    ... this disorder. Alternative Names Renal tubular acidosis - distal; Renal tubular acidosis type I; Type I RTA; RTA - distal; Classical RTA Images Kidney anatomy Kidney - blood and urine flow References Bose A, Monk RD, Bushinsky DA. Kidney ...

  14. The influence of different sub-bandage pressure values on venous leg ulcers healing when treated with compression therapy.

    Science.gov (United States)

    Milic, Dragan J; Zivic, Sasa S; Bogdanovic, Dragan C; Jovanovic, Milan M; Jankovic, Radmilo J; Milosevic, Zoran D; Stamenkovic, Dragan M; Trenkic, Marija S

    2010-03-01

    Venous leg ulcers (VLU) have a huge social and economic impact. An estimated 1.5% of European adults will suffer a venous ulcer at some point in their lives. Despite the widespread use of bandaging with high pressure in the treatment of this condition, recurrence rates range between 25% to 70%. Numerous studies have suggested that the compression system should provide sub-bandage pressure values in the range from 35 mm Hg to 45 mm Hg in order to achieve the best possible healing results. An open, randomized, prospective, single-center study was performed in order to determine the healing rates of VLU when treated with different compression systems and different sub-bandage pressure values. One hundred thirty-one patients (72 women, 59 men; mean age, 59-years-old) with VLU (ulcer surface >3 cm(2); duration >3 months) were randomized into three groups: group A - 42 patients who were treated using an open-toed, elastic, class III compression device knitted in tubular form (Tubulcus, Laboratoires Innothera, Arcueil, France); group B - 46 patients treated with the multi-component bandaging system comprised of Tubulcus and one elastic bandage (15 cm wide and 5 cm long with 200% stretch, Niva, Novi Sad, Serbia); and group C - forty-three patients treated with the multi-component bandaging system comprised of Tubulcus and two elastic bandages. Pressure measurements were taken with the Kikuhime device (TT MediTrade, Soro, Denmark) at the B1 measuring point in the supine, sitting, and standing positions under the three different compression systems. The median resting values in the supine and standing positions in examined study groups were as follows: group A - 36.2 mm Hg and 43.9 mm Hg; group B - 53.9 mm Hg and 68.2 mm Hg; group C - 74.0 mm Hg and 87.4 mm Hg. The healing rate during the 26-week treatment period was 25% (13/42) in group A, 67.4% (31/46) in group B, and 74.4% (32/43) in group C. The success of compression treatment in group A was strongly associated with the

  15. Neuromuscular Bandage: Neurophysiological Effects and the Role of Fascias

    Directory of Open Access Journals (Sweden)

    Ximena María Villota Chicaíza

    2014-05-01

    Full Text Available During the last years, neuromuscular bandage, a therapeutic application created in 1979 by doctor Kenzo Kase has been introduced in the management of many disorders of the musculo-skeletal system and even more so in the treatment of neurological disorders; This therapeutic tool which consists of a self adhesive elastic bandage allows recovery of the injured party without diminishing its bodily function. According to the existing literature on the physiological effects of this therapeutic application in the body, you could say that there is consensus. However in this article the author wants to highlight the significant although little highlighted role played by the fas¬cias on the therapeutic effects of neuromuscular bandage, analyzing from a reflective perspective the analgesic, neuromechanical and circulatory effects, as fundamental effects of neuromuscular bandage and fascias in the same function, trying to bring a global understanding on the way they relate to all connective tissues, aspects that are of great importance for the proper evaluation of alterations and prescription of neuromuscular bandage

  16. Wearable Wireless Tyrosinase Bandage and Microneedle Sensors: Toward Melanoma Screening.

    Science.gov (United States)

    Ciui, Bianca; Martin, Aida; Mishra, Rupesh K; Brunetti, Barbara; Nakagawa, Tatsuo; Dawkins, Thomas J; Lyu, Mengjia; Cristea, Cecilia; Sandulescu, Robert; Wang, Joseph

    2018-04-01

    Wearable bendable bandage-based sensor and a minimally invasive microneedle biosensor are described toward rapid screening of skin melanoma. These wearable electrochemical sensors are capable of detecting the presence of the tyrosinase (TYR) enzyme cancer biomarker in the presence of its catechol substrate, immobilized on the transducer surface. In the presence of the surface TYR biomarker, the immobilized catechol is rapidly converted to benzoquinone that is detected amperometrically, with a current signal proportional to the TYR level. The flexible epidermal bandage sensor relies on printing stress-enduring inks which display good resiliency against mechanical deformations, whereas the hollow microneedle device is filled with catechol-coated carbon paste for assessing tissue TYR levels. The bandage sensor can thus be used directly on the skin whereas microneedle device can reach melanoma tissues under the skin. Both wearable sensors are interfaced to an ultralight flexible electronic board, which transmits data wirelessly to a mobile device. The analytical performance of the resulting bandage and microneedle sensing systems are evaluated using TYR-containing agarose phantom gel and porcine skin. The new integrated conformal portable sensing platforms hold considerable promise for decentralized melanoma screening, and can be extended to the screening of other key biomarkers in skin moles. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Reliability of Tubular Joints

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Thoft-Christensen, Palle

    In this paper the preliminary results obtained by tests on tubular joints are presented. The joints are T-joints and the loading is static. It is the intention in continuation of these tests to perform tests on other types of joints (e.g. Y-joints) and also with dynamic loading. The purpose...... of the test is partly to obtain empirical data for the ultimate load-carrying capacity of tubular T-joints and partly to obtain some experience in performing tests with tubular joints. It is well known that tubular joints are usually designed in offshore engineering on the basis of empirical formulas obtained...... by experimental test results. Therefore, there is a need for performing experimental tests in this area....

  18. An advanced straight tube heat exchanger in which a fluid flows at variable and elevated temperatures

    International Nuclear Information System (INIS)

    Mauget, C.; Benoit, G.; Stalport, G.

    1993-01-01

    Straight tube heat exchangers are used as steam generators in nuclear reactors such as in fast neutron nuclear power plants; elevated and highly variable temperatures induce very high thermal expansion constraints in these long straight tubes. In order to avoid the expansion problems, an expansion bellow is disposed between the heat exchanger and the collector tubular plate in such a way that the bundle differential expansions may be absorbed

  19. Exploration of alginate hydrogel/nano zinc oxide composite bandages for infected wounds

    Directory of Open Access Journals (Sweden)

    Mohandas A

    2015-10-01

    Full Text Available Annapoorna Mohandas,* Sudheesh Kumar PT,* Biswas Raja, Vinoth-Kumar Lakshmanan, Rangasamy Jayakumar Amrita Centre for Nanosciences and Molecular Medicine, Amrita Institute of Medical Sciences and Research Centre, Amrita Vishwa Vidyapeetham University, Kochi, India *These authors contributed equally to this work Abstract: Alginate hydrogel/zinc oxide nanoparticles (nZnO composite bandage was developed by freeze-dry method from the mixture of nZnO and alginate hydrogel. The developed composite bandage was porous with porosity at a range of 60%–70%. The swelling ratios of the bandages decreased with increasing concentrations of nZnO. The composite bandages with nZnO incorporation showed controlled degradation profile and faster blood clotting ability when compared to the KALTOSTAT® and control bandages without nZnO. The prepared composite bandages exhibited excellent antimicrobial activity against Escherichia coli, Staphylococcus aureus, Candida albicans, and methicillin resistant S. aureus (MRSA. Cytocompatibility evaluation of the prepared composite bandages done on human dermal fibroblast cells by Alamar assay and infiltration studies proved that the bandages have a non-toxic nature at lower concentrations of nZnO whereas slight reduction in viability was seen with increasing nZnO concentrations. The qualitative analysis of ex-vivo re-epithelialization on porcine skin revealed keratinocyte infiltration toward wound area for nZnO alginate bandages. Keywords: alginate, hydrogel, ZnO nanoparticle, hemostatic, antimicrobial activity, wound healing

  20. Relative stiffness of 3 bandage/splint constructs for stabilization of equine midmetacarpal fractures.

    Science.gov (United States)

    Lutter, John D; Cary, Julie A; Stephens, Robert R; Potts, Logan B

    2015-01-01

    Determine the relative stiffness of 3 bandage/splint constructs intended for emergency fracture stabilization. Experimental model. A single plane free end deflection model was developed to simulate the forces placed on a bandage/splint construct during stabilization of a complete mid-metacarpal bone fracture. The total deflection of the model in one plane was measured following application of 3 different bandage/splint combinations including a classic, 3 layered Robert Jones Bandage (RJB) with a splint placed on the outside of the bandage (RJB-3), an RJB with splint placed after the first of 3 bandage layers (RJB-1), and a single layer full limb bandage with external splint (SS). Comparisons were made between the deflections of the model with each bandage/splint combinations in an effort to determine the most effective method for field fracture stabilization. Laboratory. No animals were utilized in data collection for this study. Two live horses were utilized during the pilot study. Application of bandage and splint to a model intended to simulate the bending force on a lower forelimb fracture in a horse Deflection was determined by the difference between the height of the model's supported free end before application of a 4.5 kg weight and at the conclusion of the deflection test. There was no significant difference in the amount of deflection between bandage/splint combinations (78 ± 32 mm (RJB-1), 94 ± 44 mm (RJB-3), and 93 ± 33 mm (SS)) CONCLUSIONS: The one-layer bandage with splint was equivalent to either RJB configuration in the mean amount of deflection in the simple model of a fracture. © Veterinary Emergency and Critical Care Society 2015.

  1. A comparison of inferface pressures of three compression bandage systems.

    Science.gov (United States)

    Hanna, Richard; Bohbot, Serge; Connolly, Nicki

    To measure and compare the interface pressures achieved with two compression bandage systems - a four-layer system (4LB) and a two-layer short-stretch system (SSB) - with a new two-layer system (2LB), which uses an etalonnage (performance indicator) to help achieve the correct therapeutic pressure for healing venous leg ulcers - recommended as 40 mmHg. 32 nurses with experience of using compression bandages applied each of the three systems to a healthy female volunteer in a sitting position. The interface pressures and time taken to apply the systems were measured. A questionnaire regarding the concept of the new system and its application in comparison to the existing two systems was then completed by the nurses. The interface pressures achieved show that many nurses applied very high pressures with the 4LB (25% achieving pressures > 50 mmHg) whereas the majority of the nurses (75%) achieved a pressure of pressure of 30-50 mmHg was achieved with the new 2LB. The SSB took the least time to be applied (mean: 1 minute 50 seconds) with the 4LB the slowest (mean: 3 minutes 46 seconds). A mean time of 2 minutes 35 seconds was taken to apply the 2LB. Over 63% of the nurses felt the 2LB was very easy to apply. These results suggest that the 2LB achieves the required therapeutic pressure necessary for the management of venous leg ulcers, is easy to apply and may provide a suitable alternative to other multi-layer bandage systems.

  2. Studies of a new multi-layer compression bandage for the treatment of venous ulceration.

    Science.gov (United States)

    Scriven, J M; Bello, M; Taylor, L E; Wood, A J; London, N J

    2000-03-01

    This study aimed to develop an alternative graduated compression bandage for the treatment of venous leg ulcers. Alternative bandage components were identified and assessed for optimal performance as a graduated multi-layer compression bandage. Subsequently the physical characteristics and clinical efficacy of the optimal bandage combination was prospectively examined. Ten healthy limbs were used to develop the optimal combination and 20 limbs with venous ulceration to compare the physical properties of the two bandage types. Subsequently 42 consecutive ulcerated limbs were prospectively treated to examine the efficacy of the new bandage combination. The new combination produced graduated median (range) sub-bandage pressures (mmHg) as follows: ankle 59 (42-100), calf 36 (27-67) and knee 35 (16-67). Over a seven-day period this combination maintained a comparable level of compression with the Charing Cross system, and achieved an overall healing rate at one year of 88%. The described combination should be brought to the attention of healthcare professionals treating venous ulcers as a possible alternative to other forms of multi-layer graduated compression bandages pending prospective, randomised clinical trials.

  3. Pressure mapping and performance of the compression bandage/garment for venous leg ulcer treatment.

    Science.gov (United States)

    Ghosh, S; Mukhopadhyay, A; Sikka, M; Nagla, K S

    2008-08-01

    A study has been conducted on the commercially available compression bandages as regards their performance with time. Pressure mapping of these bandages has been done using a fabricated pressure-measuring device on a mannequin leg to see the effect on pressure due to creep, fabric friction and angle of bandaging. The results show that the creep behavior, frictional behavior and the angle of bandaging have a significant effect on the pressure profile generated by the bandages during application. The regression analysis shows that the surface friction restricts the slippage in a multilayer system. Also the diameters of the limb and the amount of stretch given to the bandage during application have definite impact on the bandage pressure. In case of compression garments, washing improves the pressure generated but not to the extent of the pressure of a virgin garment. Comparing the two compression materials i.e. bandage and garment, it is found that the presence of higher percentage of elastomeric material and a highly close construction in case of garment provides better holding power and a more homogeneous pressure distribution.

  4. Straight scaling FFAG beam line

    International Nuclear Information System (INIS)

    Lagrange, J.-B.; Planche, T.; Yamakawa, E.; Uesugi, T.; Ishi, Y.; Kuriyama, Y.; Qin, B.; Okabe, K.; Mori, Y.

    2012-01-01

    Fixed field alternating gradient (FFAG) accelerators are recently subject to a strong revival. They are usually designed in a circular shape; however, it would be an asset to guide particles with no overall bend in this type of accelerator. An analytical development of a straight FFAG cell which keeps zero-chromaticity is presented here. A magnetic field law is thus obtained, called “straight scaling law”, and an experiment has been conducted to confirm this zero-chromatic law. A straight scaling FFAG prototype has been designed and manufactured, and horizontal phase advances of two different energies are measured. Results are analyzed to clarify the straight scaling law.

  5. Straight scaling FFAG beam line

    Science.gov (United States)

    Lagrange, J.-B.; Planche, T.; Yamakawa, E.; Uesugi, T.; Ishi, Y.; Kuriyama, Y.; Qin, B.; Okabe, K.; Mori, Y.

    2012-11-01

    Fixed field alternating gradient (FFAG) accelerators are recently subject to a strong revival. They are usually designed in a circular shape; however, it would be an asset to guide particles with no overall bend in this type of accelerator. An analytical development of a straight FFAG cell which keeps zero-chromaticity is presented here. A magnetic field law is thus obtained, called "straight scaling law", and an experiment has been conducted to confirm this zero-chromatic law. A straight scaling FFAG prototype has been designed and manufactured, and horizontal phase advances of two different energies are measured. Results are analyzed to clarify the straight scaling law.

  6. Measuring sub-bandage pressure: comparing the use of pressure monitors and pulse oximeters.

    Science.gov (United States)

    Satpathy, A; Hayes, S; Dodds, S R

    2006-03-01

    To test the use of low-cost sub-bandage pressure monitors and pulse oximeters as part of a quality-control measure for graduated compression bandaging in leg ulcer clinics. Twenty-five healthy volunteers (mean age 40 years) providing 50 limbs were bandaged with a four-layer compression bandaging system. The ankle systolic pressure (ASP) was measured using a pulse oximeter (Nellcor NBP-40) before applying the graduated compression bandages. Interface pressure was measured by placing pressure sensors on the skin at three points (2cm above the medial malleolus; the widest part of the calf; and a point midway between them) in the supine and standing positions. The ASP was measured again with the pulse oximeter after the bandage had been applied, and the effect of the bandage on the ASP was recorded. The actual pressure created by the bandage was compared with the required pressure profile. Interface pressures varied with change of position and movement. With the operator blinded to the pressure monitors while applying the bandages, the target pressure of 35-40mmHg at the ankle was achieved in only 36% of limbs ([mean +/- 95% confidence interval]; 32.3 +/- 1.6mmHg [supine]; 38.4 +/- 2.4mmHg [standing position]). With the help of the pressure monitors, the target pressure was achieved in 78% of the limbs. There was no correlation between the pressure monitors and pulse oximeter pressures, demonstrating that the pulse oximeter is not a useful tool for measuring sub-bandage pressures. The results suggest a tool (interface pressure monitors) that is easy to operate should be available as part of quality assurance for treatment, training of care providers and education.

  7. Tubular closure device

    International Nuclear Information System (INIS)

    Klahn, F.C.; Nolan, J.H.; Wills, C.

    1982-01-01

    This invention relates to a closure mechanism for closing openings such as the bore of a conduit and for releasably securing members within the bore. More particularly, this invention relates to a closure mechanism for tubular irradiation surveillance specimen assembly holders used in nuclear reactors

  8. Standing "Straight" up to Homophobia: Straight Allies' Involvement in GSAs

    Science.gov (United States)

    Lapointe, Alicia Anne

    2015-01-01

    This qualitative study captures the experiences of four straight allies' and one gay youth involvement in gay--straight alliances (GSAs) at their Ontario, Canada, high schools. Participants' motivations for becoming GSA members and their roles as allies are examined. Queer theoretical perspectives, as espoused by Britzman (1995, 1998) and Linville…

  9. Preparation of silver-chitosan nanocomposites and coating on bandage for antibacterial wound dressing application

    Energy Technology Data Exchange (ETDEWEB)

    Susilowati, Endang, E-mail: endwati@yahoo.co.id; Ashadi [Chemistry Education Department, Faculty of Teacher Training and Education, Universitas Sebelas Maret Surakarta (Indonesia); Maryani [Medical Doctor Program, Faculty of Medicine, Universitas Sebelas Maret Surakarta, Indonesia Jl. Ir Sutami 36 A Surakarta Indonesia 53126 (Indonesia)

    2016-02-08

    Bandage is a medical device that is essential for wound dressing. To improve the performance of the bandage, it has been coated by silver-chitosan nanocomposites (Ag/Chit) with pad-dry-cure method. The nanocomposites were performed by chemical reduction method at room temperature using glucose as reducing agent, sodium hydroxide (NaOH) as accelerator reagent, silver nitrate (AgNO{sub 3}) as metal precursor and chitosan as stabilizing agent. Localized surface plasmon resonance (LSPR) absorption band of silver nanoparticles was investigated using UV-Vis spectrophotometer. The bandage coated Ag/Chit nanocomposites (B-Ag/Chit) were characterized by fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD) and scanning electron microscope (SEM). In addition, antibacterial activity of the bandage toward Gram positive (Staphylococcus aureus) and Gram negative (Escherichia coli) were also studied. The formation of silver nanoparticles was confirmed by the appearance of LSPR absorption peak at 412.2 – 423.2 nm. Coating of nanocomposite cause increasing rigidity of bandage and decreasing on crystallinity. The bandages of B-Ag/Chit demonstrated good activity against both Gram positive (S. aureus) and Gram negative (E.Coli). Thus the bandages have a potential to be used for antibacterial wound dressing application.

  10. Does comprilan bandage have any influence on peripheral perfusion in patients with oedema?

    DEFF Research Database (Denmark)

    Midttun, M; Ahmadzay, N F; Henriksen, J H

    2010-01-01

    Comprilan bandage may be an attractive treatment of leg oedema, but theoretically bandage could compromise peripheral circulation. The present study was undertaken to investigate circulation in the first toe before, during, and after treatment with comprilan bandage. METHODS AND STUDY POPULATION......: Blood flow rate was measured by the heat-washout method in the pulp of the first toe of 10 patients (eight women, two men, aged 75-94) with leg oedemas, and systolic toe blood pressure was determined by the strain gauge method. Oedema was scored according to a visual scale, and the patients were treated...

  11. Straight Ahead in Microgravity

    Science.gov (United States)

    Wood, S. J.; Vanya, R. D.; Clement, G.

    2014-01-01

    This joint ESA-NASA study will address adaptive changes in spatial orientation related to the subjective straight ahead, and the use of a vibrotactile sensory aid to reduce perceptual errors. The study will be conducted before and after long-duration expeditions to the International Space Station (ISS) to examine how spatial processing of target location is altered following exposure to microgravity. This project specifically addresses the sensorimotor research gap "What are the changes in sensorimotor function over the course of a mission?" Six ISS crewmembers will be requested to participate in three preflight sessions (between 120 and 60 days prior to launch) and then three postflight sessions on R+0/1 day, R+4 +/-2 days, and R+8 +/-2 days. The three specific aims include: (a) fixation of actual and imagined target locations at different distances; (b) directed eye and arm movements along different spatial reference frames; and (c) the vestibulo-ocular reflex during translation motion with fixation targets at different distances. These measures will be compared between upright and tilted conditions. Measures will then be compared with and without a vibrotactile sensory aid that indicates how far one has tilted relative to the straight-ahead direction. The flight study was been approved by the medical review boards and will be implemented in the upcoming Informed Crew Briefings to solicit flight subject participation. Preliminary data has been recorded on 6 subjects during parabolic flight to examine the spatial coding of eye movements during roll tilt relative to perceived orientations while free-floating during the microgravity phase of parabolic flight or during head tilt in normal gravity. Binocular videographic recordings obtained in darkness allowed us to quantify the mean deviations in gaze trajectories along both horizontal and vertical coordinates relative to the aircraft and head orientations. During some parabolas, a vibrotactile sensory aid provided

  12. Diffraction at a Straight Edge

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 20; Issue 5. Diffraction at a Straight Edge: A Gem from Sommerfeld's Work in Classical Physics. Rajaram Nityananda. General Article Volume 20 Issue 5 May 2015 pp 389-400 ...

  13. The use of strapping to increase local pressure: reporting of a sub-bandage pressure study

    OpenAIRE

    Alison Hopkins; Fran Worboys; Hugo Partsch

    2013-01-01

    High compression is the gold standard for venous ulcer management. This brief report presents the results of a sub-bandage pressure study that investigated the pressures received from compression therapy in the region of the retromalleolal fossa. The study tested the hypothesis that therapeutic compression is not achieved behind the malleolus. The results confirm this, showing that less that 5-mmHg sub-bandage pressure is achieved despite high compression at the B1 level. This report demonstr...

  14. Tubular closure mechanism

    International Nuclear Information System (INIS)

    Kalen, D.D.; Mitchem, J.W.

    1982-01-01

    This invention relates to a closure mechanism for tubular irradiation surveillance specimen assembly holder used in nuclear reactors. The closure mechanism is composed of a latching member which includes a generally circular chamber with a plurality of elongated latches depending therefrom. The latching member circumscribes part of an actuator member which is disposed within the latching member so as to be axially movable. The axial movement of the actuator actuates positioning of the latches between positions in which the latches are locked and secured within the actuator member. Means, capable of being remotely manipulated, are provided to move the actuator in order to position the latches and load the articles within the tube

  15. Waterproof Electronic-Bandage with Tunable Sensitivity for Wearable Strain Sensors.

    Science.gov (United States)

    Jeon, Jun-Young; Ha, Tae-Jun

    2016-02-03

    We demonstrate high-performance wearable electronic-bandage (E-bandage) based on carbon nanotube (CNT)/silver nanoparticle (AgNP) composites covered with flexible media of fluoropolymer-coated polydimethylsiloxane (PDMS) films. The E-bandage can be used for motion-related sensors by directly attaching them to human skin, which achieves a fast and accurate electric response with high sensitivity according to the bending and stretching movements that induce changes in the conductivity. This advance in the E-bandage is realized as a result of the sensitivity that can be achieved by controlling the concentration of AgNPs in CNT pastes and by modifying the device architecture. The fluoropolymer encapsulation with hydrophobic surface characteristics allows for the E-bandage to operate in water and protects it from physical and chemical contact with the daily life conditions of the human skin. The reliability and scalability of the E-bandage as well as the compatibility with conventional microfabrication allow new possibilities to integrate flexible human-interactive nanoelectronics into mobile health-care monitoring systems combined with Internet of things (IoTs).

  16. Expandable tubulars for use in geologic structures

    Science.gov (United States)

    Spray, Jeffery A.; Svedeman, Steven; Walter, David; Mckeighan, Peter; Siebanaler, Shane; Dewhurst, Peter; Hobson, Steven; Foss, Doug; Wirz, Holger; Sharpe, Aaron; Apostal, Michael

    2014-08-12

    An expandable tubular includes a plurality of leaves formed from sheet material that have curved surfaces. The leaves extend around a portion or fully around the diameter of the tubular structure. Some of the adjacent leaves of the tubular are coupled together. The tubular is compressed to a smaller diameter so that it can be inserted through previously deployed tubular assemblies. Once the tubular is properly positioned, it is deployed and coupled or not coupled to a previously deployed tubular assembly. The tubular is useful for all types of wells and boreholes.

  17. Tubular closure mechanism

    International Nuclear Information System (INIS)

    Kalen, D.D.; Mitchem, J.W.

    1981-01-01

    An apparatus is provided for closing the bore of a tube and releasably securing articles within the tube under longitudinal load. A latching member has a cylindrical section and several circumferentially-spaced elongated latches hanging down from one end of the cylinder. An elongated actuator has integral cam and spline and is partly located within the latch with the cam radially contacting the latches and the spline projecting into the circumferential spaces between the latches. The actuator is axially movable between a position in which the latches are locked to the tube walls and a position in which the latches are secured from contact with the tube walls. Means are provided for axially moving the actuator such that the cam positions the latches; and means are also provided for engaging the articles within the tube. The closure is particularly applicable to tubular irradiation surveillance specimen assembly holders used in reactors

  18. Elastic Bandaging for Orthopedic- and Sports-Injury Prevention and Rehabilitation: A Systematic Review.

    Science.gov (United States)

    Fousekis, Konstantinos; Billis, Evdokia; Matzaroglou, Charalampos; Mylonas, Konstantinos; Koutsojannis, Constantinos; Tsepis, Elias

    2017-05-01

    Elastic bandages are commonly used in sports to treat and prevent sport injuries. To conduct a systematic review assessing the effectiveness of elastic bandaging in orthopedic- and sports-injury prevention and rehabilitation. The researchers searched the electronic databases MEDLINE, CINAHL, SPORTDiscus, EMBASE, and Physiotherapy Evidence Database (PEDro) with keywords elastic bandaging in combination, respectively, with first aid, sports injuries, orthopedic injuries, and sports injuries prevention and rehabilitation. Research studies were selected based on the use of the term elastic bandaging in the abstract. Final selection was made by applying inclusion and exclusion criteria to the full text. Studies were included if they were peer-reviewed clinical trials written in English on the effects of elastic bandaging for orthopedic-injury prevention and rehabilitation. Twelve studies met the criteria and were included in the final analysis. Data collected included number of participants, condition being treated, treatment used, control group, outcome measures, and results. Studies were critically analyzed using the PEDro scale. The studies in this review fell into 2 categories: studies in athletes (n = 2) and nonathletes (n = 10). All included trials had moderate to high quality, scoring ≥5 on the PEDro scale. The PEDro scores for the studies in athletes and nonathletes ranged from 5 to 6 out of 10 and from 5 to 8 out of 10, respectively. The quality of studies was mixed, ranging from higher- to moderate-quality methodological clinical trials. Overall, elastic bandaging can assist proprioceptive function of knee and ankle joint. Because of the moderate methodological quality and insufficient number of clinical trials, further effects of elastic bandaging could not be confirmed.

  19. Bi-layered nanocomposite bandages for controlling microbial infections and overproduction of matrix metalloproteinase activity.

    Science.gov (United States)

    Anjana, J; Mohandas, Annapoorna; Seethalakshmy, S; Suresh, Maneesha K; Menon, Riju; Biswas, Raja; Jayakumar, R

    2018-04-15

    Chronic diabetic wounds is characterised by increased microbial contamination and overproduction of matrix metalloproteases that would degrade the extracellular matrix. A bi-layer bandage was developed, that promotes the inhibition of microbial infections and matrix metalloprotease (MMPs) activity. Bi-layer bandage containing benzalkonium chloride loaded gelatin nanoparticles (BZK GNPs) in chitosan-Hyaluronic acid (HA) as a bottom layer and sodium alendronate containing chitosan as top layer was developed. We hypothesized that the chitosan-gelatin top layer with sodium alendronate could inhibit the MMPs activity, whereas the chitosan-HA bottom layer with BZK GNPs (240±66nm) would enable the elimination of microbes. The porosity, swelling and degradation nature of the prepared Bi-layered bandage was studied. The bottom layer could degrade within 4days whereas the top layer remained upto 7days. The antimicrobial activity of the BZK NPs loaded bandage was determined using normal and clinical strains. Gelatin zymography shows that the proteolytic activity of MMP was inhibited by the bandage. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Tubular nanostructured materials for bioapplications

    Science.gov (United States)

    Xie, Jining; Chen, Linfeng; Srivatsan, Malathi; Varadan, Vijay K.

    2009-03-01

    Tubular nanomaterials possess hollow structures as well as high aspect ratios. In addition to their unique physical and chemical properties induced by their nanoscale dimensions, their inner voids and outer surfaces make them ideal candidates for a number of biomedical applications. In this work, three types of tubular nanomaterials including carbon nanotubes, hematite nanotubes, and maghemite nanotubes, were synthesized by different chemical techniques. Their structural and crystalline properties were characterized. For potential bioapplications of tubular nanomaterials, experimental investigations were carried out to demonstrate the feasibility of using carbon nanotubes, hematite nanotubes, and maghemite nanotubes in glucose sensing, neuronal growth, and drug delivery, respectively. Preliminary results show the promise of tubular nanomaterials in future biomedical applications.

  1. Low Cost Inkjet Printed Smart Bandage for Wireless Monitoring of Chronic Wounds

    KAUST Repository

    Farooqui, Muhammad Fahad

    2016-06-29

    Chronic wounds affect millions of patients around the world and their treatment is challenging as the early signs indicating their development are subtle. In addition, a type of chronic wound, known as pressure ulcer, develops in patients with limited mobility. Infection and frequent bleeding are indicators of chronic wound development. In this article, we present an unprecedented low cost continuous wireless monitoring system, realized through inkjet printing on a standard bandage, which can send early warnings for the parameters like irregular bleeding, variations in pH levels and external pressure at wound site. In addition to the early warnings, this smart bandage concept can provide long term wound progression data to the health care providers. The smart bandage comprises a disposable part which has the inkjet printed sensors and a reusable part constituting the wireless electronics. This work is an important step towards futuristic wearable sensors for remote health care applications.

  2. Low Cost Inkjet Printed Smart Bandage for Wireless Monitoring of Chronic Wounds

    Science.gov (United States)

    Farooqui, Muhammad Fahad; Shamim, Atif

    2016-06-01

    Chronic wounds affect millions of patients around the world and their treatment is challenging as the early signs indicating their development are subtle. In addition, a type of chronic wound, known as pressure ulcer, develops in patients with limited mobility. Infection and frequent bleeding are indicators of chronic wound development. In this article, we present an unprecedented low cost continuous wireless monitoring system, realized through inkjet printing on a standard bandage, which can send early warnings for the parameters like irregular bleeding, variations in pH levels and external pressure at wound site. In addition to the early warnings, this smart bandage concept can provide long term wound progression data to the health care providers. The smart bandage comprises a disposable part which has the inkjet printed sensors and a reusable part constituting the wireless electronics. This work is an important step towards futuristic wearable sensors for remote health care applications.

  3. Low Cost Inkjet Printed Smart Bandage for Wireless Monitoring of Chronic Wounds.

    Science.gov (United States)

    Farooqui, Muhammad Fahad; Shamim, Atif

    2016-06-29

    Chronic wounds affect millions of patients around the world and their treatment is challenging as the early signs indicating their development are subtle. In addition, a type of chronic wound, known as pressure ulcer, develops in patients with limited mobility. Infection and frequent bleeding are indicators of chronic wound development. In this article, we present an unprecedented low cost continuous wireless monitoring system, realized through inkjet printing on a standard bandage, which can send early warnings for the parameters like irregular bleeding, variations in pH levels and external pressure at wound site. In addition to the early warnings, this smart bandage concept can provide long term wound progression data to the health care providers. The smart bandage comprises a disposable part which has the inkjet printed sensors and a reusable part constituting the wireless electronics. This work is an important step towards futuristic wearable sensors for remote health care applications.

  4. Preparation of the egg membrane bandage contained the antibacterial Ag nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jin; Duan, Guangwen [Department of Materials and Chemical Engineering, Hainan University, 570228 Haikou (China); Fu, Yunzhi, E-mail: yzhfu@hainu.edu.cn [Department of Materials and Chemical Engineering, Hainan University, 570228 Haikou (China); Zhao, Jinsheng [Shandong Key Laboratory of Chemical Energy-Storage and Novel Cell Technology, Liaocheng University, 252059 Liaocheng (China)

    2015-02-15

    Silver nanoparticles were synthesized using a rapid, single step, and completely green biosynthetic method employing aqueous aloe leaf extracts as both the reducing and capping agent. Transmission electron microscopy analysis revealed the average size of silver nanoparticles approximately 18.05 nm. Fourier transform infrared spectroscopy observation showed the estimation of two kinds of binding sites between aqueous aloe leaf and aqueous aloe leaf with silver nanoparticles. In addition, the critical roles of the concentration of silver nitrate, temperature, and reaction time in the formation of silver nanoparticles had been illustrated. Furthermore, silver nanoparticles were deposited on egg membrane bandage, forming a new egg membrane bandage that contained silver nanoparticles that exhibiting excellent antibacterial effects against Gram-negative Escherichia coli and Gram-positive Staphylococcus aureus, which was 2.5 times stronger than the commercially available bandage. - Graphical Abstract: Display Omitted.

  5. Low Cost Inkjet Printed Smart Bandage for Wireless Monitoring of Chronic Wounds

    KAUST Repository

    Farooqui, Muhammad Fahad; Shamim, Atif

    2016-01-01

    Chronic wounds affect millions of patients around the world and their treatment is challenging as the early signs indicating their development are subtle. In addition, a type of chronic wound, known as pressure ulcer, develops in patients with limited mobility. Infection and frequent bleeding are indicators of chronic wound development. In this article, we present an unprecedented low cost continuous wireless monitoring system, realized through inkjet printing on a standard bandage, which can send early warnings for the parameters like irregular bleeding, variations in pH levels and external pressure at wound site. In addition to the early warnings, this smart bandage concept can provide long term wound progression data to the health care providers. The smart bandage comprises a disposable part which has the inkjet printed sensors and a reusable part constituting the wireless electronics. This work is an important step towards futuristic wearable sensors for remote health care applications.

  6. A medical bandage in an Italian Renaissance mummy (Naples, XVI century).

    Science.gov (United States)

    Giuffra, Valentina; Marinozzi, Silvia; Vultaggio, Claudia; Fornaciari, Gino

    2008-01-01

    A dressing was observed on the left arm of the mummy of Mary of Aragon (1503-1568), under her precious Renaissance clothes. It consisted of a true medical bandage, covering a large syphilitic cutaneous ulcer, with a sulphur-embedded wad still in situ. The bandage has a very peculiar shape, rather different from the usual dressings described in the contemporary medical texts: a central rectangular pad, used as compressing appliance, is provided with a sort of pocket containing ivy leaves. The function of the dressing was not only to cover and protect the ulcer, but also to apply a plant drug. This is the first case of ancient medical bandage studied directly on a mummified body.

  7. Loss of interface pressure in various compression bandage systems over seven days.

    Science.gov (United States)

    Protz, Kerstin; Heyer, Kristina; Verheyen-Cronau, Ida; Augustin, Matthias

    2014-01-01

    Manufacturers' instructions of multi-component compression bandage systems inform that these products can remain up to 7 days during the therapy of venous leg ulcer. This implies that the pressure needed will be sustained during this time. The present research investigated the persistence of pressure of compression systems over 7 days. All 6 compression systems available in Germany at the time of the trial were tested on 35 volunteering persons without signs of venous leg disease. Bandaging with short-stretch bandages was included for comparison. Pressure was measured by using PicoPress®. Initially, all products showed sufficient resting pressure of 40 mm Hg checked with a pressure monitor, except for one system in which the pressure fell by at least 23.8%, the maximum being 47.5% over a period of 7 days. The currently available compression systems are not fit to keep the required pressure. Optimized products need to be developed.

  8. The impact of decongestive physical therapy and elastic bandaging on the control of pain in patients with venous ulcers

    Directory of Open Access Journals (Sweden)

    GERALDO MAGELA SALOMÉ

    2018-03-01

    Full Text Available ABSTRACT Objective: to evaluate pain in individuals with venous ulcers treated with elastic bandage and decongestant physical therapy. Methods: we studied 90 patients, divided into three groups with 30 patients each: a group treated with elastic bandage and decongestant physical therapy; a group treated with elastic bandage; and a group treated only with primary dressing according to tissue type and presence of exudate. We used the Pain Numerical Scale to quantify pain intensity and the McGill Pain Questionnaire for pain qualitative assessment. Results: in the first evaluation, all patients who participated in the study reported intense pain. In the fifth evaluation, the majority of patients treated with elastic bandaging and decongestant physical therapy did not report pain; the majority of patients in the elastic bandage group reported mild pain; and most patients treated only with primary dressing reported mild to moderate pain. During all five assessments using the McGill questionnaire, most patients in the elastic bandaging and primary dressing groups used descriptors of the sensory, affective, evaluative and miscellaneous groups to describe their pain. However, in the fourth and fifth evaluations, most patients who received decongestant physical therapy combined with elastic bandaging treatment did not use any of the descriptors. Conclusion: patients treated with decongestant physical therapy and elastic bandage presented pain improvement from the third evaluation performed on.

  9. The production and measurement of sub-bandage pressure: Laplace's Law revisited.

    Science.gov (United States)

    Thomas, S

    2014-05-01

    The present study was undertaken to demonstrate that the pressures produced by multiple layers of compression bandages applied to artificial limbs of known circumference with predetermined levels of tension can be predicted accurately using the modified Laplace equation. Up to four layers of different bandage types were applied in a carefully controlled fashion to cylinders of known circumference, with tensions ranging from around 200-2000 grams/10cm width. The pressures generated were measured using pneumatic pressure sensors previously shown to possess the required degree of accuracy for this type of experimental system. Good correlation was observed between the mean and standard deviation of each pair of experimental and calculated pressure values for all combinations of bandage type, application tension and cylinder circumference. Over the clinically relevant range of pressures, the difference between data sets was generally less than 1.0mmHg. The results of this experimental study unequivocally prove that provided accurate values for all the relevant variables are known, it is possible to predict the pressure that will be developed by a compression bandage on a limb of known size. However, it is important to recognise that other factors such as the elastomeric properties of the fabric will have a major effect upon the ability of a bandage system to sustain initial compression values. Furthermore, the variation in radius of curvature around a limb will mean that point pressures readings recorded at individual locations around the circumference may vary dramatically from the average value predicted by the modified Laplace equation, calling into question the value of sub-bandage pressure measuring devices for this application.

  10. Randomized trial of four-layer and two-layer bandage systems in the management of chronic venous ulceration.

    Science.gov (United States)

    Moffatt, Christine J; McCullagh, Lynn; O'Connor, Theresa; Doherty, Debra C; Hourican, Catherine; Stevens, Julie; Mole, Trevor; Franks, Peter J

    2003-01-01

    To compare a four-layer bandage system with a two-layer system in the management of chronic venous leg ulceration, a prospective randomized open parallel groups trial was undertaken. In total, 112 patients newly presenting to leg ulcer services with chronic leg ulceration, screened to exclude the presence of arterial disease (ankle brachial pressure index ulceration other than venous disease, were entered into the trial. Patients were randomized to receive either four-layer (Profore) or two-layer (Surepress) high-compression elastic bandage systems. In all, 109 out of 112 patients had at least one follow-up. After 24 weeks, 50 out of 57 (88%) patients randomized to the four-layer bandage system with follow-up had ulcer closure (full epithelialization) compared with 40 out of 52 (77%) on the two-layer bandage, hazard ratio = 1.18 (95% confidence interval 0.69-2.02), p = 0.55. After 12 weeks, 40 out of 57 (70%) patients randomized to the four-layer bandage system with follow-up had ulcer closure compared with 30 out of 52 (58%) on the two-layer bandage, odds ratio = 4.23 (95% confidence interval 1.29-13.86), p = 0.02. Withdrawal rates were significantly greater on the two-layer bandage (30 out of 54; 56%) compared with the four-layer bandage system (8 out of 58; 14%), p bandaging system (15 out of 54; 28%) compared with four-layer bandaging (5 out of 54; 9%), p = 0.01. The higher mean cost of treatment in the two-layer bandaging system arm over 24 weeks ($1374 [ pound 916] vs. $1314 [ pound 876]) was explained by the increased mean number of bandage changes (1.5 vs. 1.1 per week) with the two-layer system. In conclusion, the four-layer bandage offers advantages over the two-layer bandage in terms of reduced withdrawal from treatment, fewer adverse incidents, and lower treatment cost.

  11. Comparison of low-strength compression stockings with bandages for the treatment of recalcitrant venous ulcers.

    Science.gov (United States)

    Brizzio, Eugenio; Amsler, Felix; Lun, Bertrand; Blättler, Werner

    2010-02-01

    To compare the proportion and rate of healing, pain, and quality of life of low-strength medical compression stockings (MCS) with traditional bandages applied for the treatment of recalcitrant venous leg ulcers. A single-center, randomized, open-label study was performed with consecutive patients. Sigvaris prototype MCS providing 15 mm Hg-25 mm Hg at the ankle were compared with multi-layer short-stretch bandages. In both groups, pads were placed above incompetent perforating veins in the ulcer area. The initial static pressure between the dressing-covered ulcer and the pad was 29 mm Hg and 49 mm Hg with MCS and bandages, respectively. Dynamic pressure measurements showed no difference. Compression was maintained day and night and changed every week. The primary endpoint was healing within 90 days. Secondary endpoints were healing within 180 days, time to healing, pain (weekly Likert scales), and monthly quality of life (ChronIc Venous Insufficiency Quality of Life [CIVIQ] questionnaire). Of 74 patients screened, 60 fulfilled the selection criteria and 55 completed the study; 28 in the MCS and 27 in the bandage group. Ulcers were recurrent (48%), long lasting (mean, 27 months), and large (mean, 13 cm2). All but one patient had deep venous reflux and/or incompetent perforating veins in addition to trunk varices. Characteristics of patients and ulcers were evenly distributed (exception: more edema in the MCS group; P = .019). Healing within 90 days was observed in 36% with MCS and in 48% with bandages (P = .350). Healing within 180 days was documented in 50% with MCS and in 67% with bandages (P = .210). Time to healing was identical. Pain scored 44 and 46 initially (on a scale in which 100 referred to maximum and 0 to no pain) and decreased within the first week to 20 and 28 in the MCS and bandage groups, respectively (P ulcers only. Our study illustrates the difficulty of bringing large and long-standing venous ulcers to heal. The effect of compression with MCS was

  12. Feasibility study of polyurethane shape-memory polymer actuators for pressure bandage application

    International Nuclear Information System (INIS)

    Ahmad, Manzoor; Luo Jikui; Miraftab, Mohsen

    2012-01-01

    The feasibility of laboratory-synthesized polyurethane-based shape-memory polymer (SMPU) actuators has been investigated for possible application in medical pressure bandages where gradient pressure is required between the ankle and the knee for treatment of leg ulcers. In this study, using heat as the stimulant, SMPU strip actuators have been subjected to gradual and cyclic stresses; their recovery force, reproducibility and reusability have been monitored with respect to changes in temperature and circumference of a model leg, and the stress relaxation at various temperatures has been investigated. The findings suggest that SMPU actuators can be used for the development of the next generation of pressure bandages.

  13. Feasibility study of polyurethane shape-memory polymer actuators for pressure bandage application.

    Science.gov (United States)

    Ahmad, Manzoor; Luo, Jikui; Miraftab, Mohsen

    2012-02-01

    The feasibility of laboratory-synthesized polyurethane-based shape-memory polymer (SMPU) actuators has been investigated for possible application in medical pressure bandages where gradient pressure is required between the ankle and the knee for treatment of leg ulcers. In this study, using heat as the stimulant, SMPU strip actuators have been subjected to gradual and cyclic stresses; their recovery force, reproducibility and reusability have been monitored with respect to changes in temperature and circumference of a model leg, and the stress relaxation at various temperatures has been investigated. The findings suggest that SMPU actuators can be used for the development of the next generation of pressure bandages.

  14. The use of strapping to increase local pressure: reporting of a sub-bandage pressure study

    Directory of Open Access Journals (Sweden)

    Alison Hopkins

    2013-04-01

    Full Text Available High compression is the gold standard for venous ulcer management. This brief report presents the results of a sub-bandage pressure study that investigated the pressures received from compression therapy in the region of the retromalleolal fossa. The study tested the hypothesis that therapeutic compression is not achieved behind the malleolus. The results confirm this, showing that less that 5-mmHg sub-bandage pressure is achieved despite high compression at the B1 level. This report demonstrates that the application of novel strapping below the malleolus substantially increases the compression at rest, standing and dorsiflexion. The clinical implications of this are discussed.

  15. Straight nearness spaces | Bentley | Quaestiones Mathematicae

    African Journals Online (AJOL)

    Straight spaces are spaces for which a continuous map defined on the space which is uniformly continuous on each set of a finite closed cover is then uniformly continuous on the whole space. Previously, straight spaces have been studied in the setting of metric spaces. In this paper, we present a study of straight spaces in ...

  16. Straightness measurement of large machine guideways

    Directory of Open Access Journals (Sweden)

    W. Ptaszyñski

    2011-10-01

    Full Text Available This paper shows the guideway types of large machines and describes problems with their straightness measurement. A short description of straightness measurement methods and the results of investigation in straightness of 10 meter long guideways of a CNC machine by means of the XL-10 Renishaw interferometer are also presented.

  17. Experimental Investigation of Chatter Dynamics in Thin-walled Tubular Parts Turning

    OpenAIRE

    GERASIMENKO, Artem; GUSKOV, Mikhail; LORONG, Philippe; DUCHEMIN, Jérôme; GOUSKOV, Alexander

    2016-01-01

    Chatter prediction is nowadays frequently carried out for machining operations involving deformable parts or tools. These analyses are commonly based on the uncoupled elements of the system: frequency response of the deformable parts under non-rotating conditions and cutting law. The present investigation puts forward the dynamics of a thin-walled tubular part during straight axial turning undergoing chatter instability. Studied system’s peculiarities include quasi-static nominal cutting cond...

  18. Study of the effect of composition and construction of material on sub-bandage pressure during dynamic loading of a limb in vitro.

    Science.gov (United States)

    Kumar, Bipin; Das, Apurba; Alagirusamy, R

    2013-01-01

    Internal stress in a compression bandage wrapped over a limb in vitro is expected to reduce over time because of fatigue which may occur due to repetitive and prolonged variations in the extension of the bandage during posture change and exercise. This phenomenon may cause significant variation in the sub-bandage pressure over time. To examine the effect of composition and construction of material on the sub-bandage pressure variation over time in the dynamic state of a limb in the laboratory. Yarns comprising fibers of polyester, viscose, cotton and elastomeric yarn were used to prepare different knitted bandage samples having varying thread densities in the structure. A leg-segment prototype was used for the measurement of the interface pressure over a mannequin limb to analyse different bandages under similar dynamic conditions. The pressure drop in the dynamic state of the mannequin limb was greater than that in the static state. The mean pressure drop in 2 h in the dynamic state was greater by >30% for bandages made of pure cotton or viscose yarns than for bandages having elastomeric yarns in their structure. At the same applied tension, increasing the number of yarns per unit length in the bandage structure resulted in a smaller drop in pressure in the dynamic mode. Elastomeric yarn improves the elasticity and fatigue resistance of the bandage. Therefore, these yarns should be used in bandages to obtain sustained compression effects under dynamic conditions.

  19. Sub-bandage sensing system for remote monitoring of chronic wounds in healthcare

    Science.gov (United States)

    Hariz, Alex; Mehmood, Nasir; Voelcker, Nico

    2015-12-01

    Chronic wounds, such as venous leg ulcers, can be monitored non-invasively by using modern sensing devices and wireless technologies. The development of such wireless diagnostic tools may improve chronic wound management by providing evidence on efficacy of treatments being provided. In this paper we present a low-power portable telemetric system for wound condition sensing and monitoring. The system aims at measuring and transmitting real-time information of wound-site temperature, sub-bandage pressure and moisture level from within the wound dressing. The system comprises commercially available non-invasive temperature, moisture, and pressure sensors, which are interfaced with a telemetry device on a flexible 0.15 mm thick printed circuit material, making up a lightweight biocompatible sensing device. The real-time data obtained is transmitted wirelessly to a portable receiver which displays the measured values. The performance of the whole telemetric sensing system is validated on a mannequin leg using commercial compression bandages and dressings. A number of trials on a healthy human volunteer are performed where treatment conditions were emulated using various compression bandage configurations. A reliable and repeatable performance of the system is achieved under compression bandage and with minimal discomfort to the volunteer. The system is capable of reporting instantaneous changes in bandage pressure, moisture level and local temperature at wound site with average measurement resolutions of 0.5 mmHg, 3.0 %RH, and 0.2 °C respectively. Effective range of data transmission is 4-5 m in an open environment.

  20. Modifications in straight wire treatment.

    Science.gov (United States)

    Cardona, Alvin

    2010-01-01

    Orthodontic treatments have been modified with each new generation of clinicians. Today the emphasis is on facial esthetics and healthy temporomandibular joints. With orthopedic treatment, we can develop dental arches to get the necessary space to align the teeth and we can reach adequate function and esthetics, all within relatively good stability. By combining two-phase treatment with low friction fixed orthodontics and super elastic wires we produce light but continuous forces and we can provide better treatment than before. These types of forces cause physiological and functional orthopedic orthodontic reactions. The purpose of this article is to demonstrate our fixed orthopedic and orthodontic approach called "Modified Straight Wire" or "Physiologic Arch Technique." This technique is very successful with our patients because it can exert slow and continuous forces with minimal patient cooperation.

  1. Effect of Multi-layer Compression Bandage Systems on Leg Ulcers Associated with Chronic Venous Insufficiency

    Directory of Open Access Journals (Sweden)

    Hüseyin Kuplay

    2013-03-01

    Full Text Available Introduction: Venous leg ulcer is a major health problem in terms of high prevalence and high cost for treatment. Multi-layer compression bandage systems for venous leg ulcers are supposed to be the gold standard for the treatment of venous ulcers. The aim of the current study is to investigate the effectiveness of multi-layer compression bandage systems for the treatment of venous leg ulcers.Patients and Methods: Nineteen consecutive patients diagnosed to have leg ulcers were evaluated and four patients were excluded from the study due to the peripheral arterial disease. Fifteen patients, enrolled in the study, were classified according to CEAP classification and belonged to the same class. Betaven® multi-layer compression bandage was applied to patients. Patients were followed-up in terms of wound healing and reduction in wound diameter.Results: Twelve male and three female patients underwent multi-layer bandage system. Mean age of patients was 38.2 ± 4.2 years. Ulcer size was measured planimetrically and baseline ulcer size was 4-10 cm². The location of ulcer was on medial malloelus in seven patients, lateral malleolus in three patients, anterior surface of the leg in four patients and lateral side of the leg in one patient. Patients had chronic venous insuuficiency for a mean of 5.1 ± 2.1 years. CEAP classifications were C6, Ep, As2,3-p18, Pr2,3, 18. Each bandage was changed five days after application along with wound care. Mean duration of treatment was 6 ± 2 weeks. Complete healing of the venous ulcers occurred in all patients except for one. This patient was referred to plastic surgery clinic for reconstruction.Conclusion: Multi-layer compression bandage system is an effective method of treatment for venous leg ulcers associated with chronic venous insufficiency by reducing venous return and increasing intertitial tissue pressure. This effect occurred in the shortrun as well as with a low cost and prevented loss of labor.

  2. Maggots as a wound debridement agent for chronic venous leg ulcers under graduated compression bandages: A randomised controlled trial.

    Science.gov (United States)

    Davies, C E; Woolfrey, G; Hogg, N; Dyer, J; Cooper, A; Waldron, J; Bulbulia, R; Whyman, M R; Poskitt, K R

    2015-12-01

    Slough in chronic venous leg ulcers may be associated with delayed healing. The purpose of this study was to assess larval debridement in chronic venous leg ulcers and to assess subsequent effect on healing. All patients with chronic leg ulcers presenting to the leg ulcer service were evaluated for the study. Exclusion criteria were: ankle brachial pressure indices 1.25, no venous reflux on duplex and ulcer surface covered with slough. Participants were randomly allocated to either 4-layer compression bandaging alone or 4-layer compression bandaging + larvae. Surface areas of ulcer and slough were assessed on day 4; 4-layer compression bandaging was then continued and ulcer size was measured every 2 weeks for up to 12 weeks. A total of 601 patients with chronic leg ulcers were screened between November 2008 and July 2012. Of these, 20 were randomised to 4-layer compression bandaging and 20 to 4-layer compression bandaging + larvae. Median (range) ulcer size was 10.8 (3-21.3) cm(2) and 8.1 (4.3-13.5) cm(2) in the 4-layer compression bandaging and 4-layer compression bandaging + larvae groups, respectively (Mann-Whitney U test, P = 0.184). On day 4, median reduction in slough area was 3.7 cm(2) in the 4-layer compression bandaging group (P bandaging + larvae group. Median percentage area reduction of slough was 50% in the 4-layer compression bandaging group and 84% in the 4-layer compression bandaging + larvae group (Mann-Whitney U test, P bandaging and 4-layer compression bandaging + larvae groups, respectively (Kaplan-Meier analysis, P = 0.664). Larval debridement therapy improves wound debridement in chronic venous leg ulcers treated with multilayer compression bandages. However, no subsequent improvement in ulcer healing was demonstrated. © The Author(s) 2014.

  3. Comparison Between Bandage Contact Lenses and Pressure Patching on the Erosion Area and Pain Scale in Patients With Corneal Erosion.

    Science.gov (United States)

    Triharpini, Ni Nyoman; Gede Jayanegara, I Wayan; Handayani, Ariesanti Tri; Widiana, I Gde Raka

    2015-01-01

    Corneal erosion is common in eye emergency cases. Extensive corneal erosions result in severe pain and prolonged healing time. This study aimed to compare bandage contact lenses with pressure patching in terms of reducing the size of the erosion area, pain scale in patients with corneal erosion and its complications. A randomized open-label clinical trial was conducted. Subjects with mechanical corneal erosion were selected to use either bandage contact lenses or pressure patching. All subjects received antibiotic eye drops and 0.5% tropicamide eye drops. Evaluations were done 24 and 72 hours after treatment. The size of the corneal erosion area, pain scale, and complications were assessed. A total of 32 eyes (16 eyes in each group) were studied. The change in the size of the corneal erosion area was greater in the bandage contact lens group than in the pressure patching group, although there was no significant difference. In the bandage contact lens group, 56.25% of the eyes were healed at 24 hours and 43.75% were healed at 72 hours. In the pressure patching group, 62.50% were healed at 24 hours and 12.50% were healed at 72 hours. The change in pain scale was significantly greater in the bandage contact lens group than in the pressure patching group. No complications were found in both groups. Bandage contact lenses are an effective alternative to treating mechanical corneal erosion because of their effect in reducing pain without causing any complications.

  4. Jelly-like bandage helps heal wounds: Egypt develops hydrogels using irradiated polymers

    International Nuclear Information System (INIS)

    Dixit, Aabha

    2015-01-01

    Patients suffering from burn injuries, skin ulcers and bed sores can find relief using unique jelly-like materials — hydrogels — that are playing an increasingly vital role in the healing process of such wounds. Nuclear technology has been crucial in developing hydrogels that form an important part of treating wounds in many low and middle income countries including Egypt. The exceptional gel bandage is fast becoming ubiquitous to ‘cool’ wounds and reduce the painful effects of burns and other injuries. The wounds of diabetic patients have healed much faster and better than with traditional bandages, said El-Sayed A. Hegazy, Professor Emeritus and former Chairman of the National Centre for Radiation Research and Technology (NCRRT) of Egypt, the only facility in the country to develop hydrogels.

  5. Assembling the LHC short straight sections

    CERN Document Server

    Maximilien Brice

    2005-01-01

    The building where the short straight sections are being assembled, was often called ‘Lego Land’ by the workers because of the wide variety of sets of magnets and cryostats. Short straight sections contain magnets for manipulating the beam inside cryostats with liquid helium to keep the magnets at a cool 1.9 K (-271.3°C).

  6. Low Cost Inkjet Printed Smart Bandage for Wireless Monitoring of Chronic Wounds

    OpenAIRE

    Farooqui, Muhammad Fahad; Shamim, Atif

    2016-01-01

    Chronic wounds affect millions of patients around the world and their treatment is challenging as the early signs indicating their development are subtle. In addition, a type of chronic wound, known as pressure ulcer, develops in patients with limited mobility. Infection and frequent bleeding are indicators of chronic wound development. In this article, we present an unprecedented low cost continuous wireless monitoring system, realized through inkjet printing on a standard bandage, which can...

  7. Application of fibrin glue with bandage contact lens in pterygium surgery

    Directory of Open Access Journals (Sweden)

    Wei Liu

    2014-05-01

    Full Text Available AIM: To explore the efficacy of fibrin glue with bandage contact lens for pain relief after pterygium surgery performed with limbal autograft transplantation.METHODS: A prospective clinical trial was carried out in 52 patients(72 eyesoperated for primary nasal pterygium. All patients were randomly divided into the fibrin glue with bandage contact lens group(experimental group, 28 cases, 38 eyesand suture group(control group, 24 cases, 34 eyes. Autologous limbal graft taken from the superotemporal limbus was used to cover the sclera after pterygium excision under local anesthesia with 20g/L lidocaine. In experimental group, the transplant was attached to the sclera with fibrin tissue adhesive and in control group with 10-0 Virgin silk sutures. Experimental group weared bandage contact lens after surgery while the control group did not. The degree of pain after surgery was evaluated at 1, 2, 3, 5 and 7d after surgery. Follow-up was 6mo, matching degree of graft and complication such as infection, relapse, implant healing badness and subconjunctival cyst were mainly observed and recorded.RESULTS: The pain index scores of the experimental group were significantly less than those of control group(all P=0.000. In observation period, all conjunctival autografts in both groups were successfully attached and were intact without falling off, dissolution or recurrence and there were no complications such as infection, relapse, implant healing badness and subconjunctival cyst.CONCLUSION: Fibrin glue with bandage contact lens could significantly release pain response afterpterygium excision surgery.

  8. Weighted straight skeletons in the plane.

    Science.gov (United States)

    Biedl, Therese; Held, Martin; Huber, Stefan; Kaaser, Dominik; Palfrader, Peter

    2015-02-01

    We investigate weighted straight skeletons from a geometric, graph-theoretical, and combinatorial point of view. We start with a thorough definition and shed light on some ambiguity issues in the procedural definition. We investigate the geometry, combinatorics, and topology of faces and the roof model, and we discuss in which cases a weighted straight skeleton is connected. Finally, we show that the weighted straight skeleton of even a simple polygon may be non-planar and may contain cycles, and we discuss under which restrictions on the weights and/or the input polygon the weighted straight skeleton still behaves similar to its unweighted counterpart. In particular, we obtain a non-procedural description and a linear-time construction algorithm for the straight skeleton of strictly convex polygons with arbitrary weights.

  9. Straight sinus thrombosis during neurosurgical operation.

    Science.gov (United States)

    Kawano, Hiroto; Nitta, Naoki; Nozaki, Kazuhiko

    2016-01-01

    Perioperative straight sinus thrombosis is extremely rare. A 59-year-old female was admitted to our department because of incidentally found small anterior cerebral artery (A1) aneurysm with microbleeding. After clipping the cerebral aneurysm, she had delayed emergence from anesthesia, total aphasia, and right hemiparesis. Fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI) of the head showed hyperintensity in the bilateral caudate nuclei, putamina, and thalami, and computed tomography of the head showed a hyperdense straight sinus, suggesting straight sinus thrombosis. Her neurologic symptoms improved gradually, and she achieved a full clinical recovery, with radiological evidence of recanalization of the straight sinus at follow-up. The possibility of straight sinus thrombosis should be considered in postoperative patients with unexplained postoperative deficits when MRI demonstrates hyperintensity in the bilateral basal ganglia and thalami on FLAIR signal images.

  10. Comparison Between a New, Two-component Compression System With Zinc Paste Bandages for Leg Ulcer Healing: A Prospective, Multicenter, Randomized, Controlled Trial Monitoring Sub-bandage Pressures.

    Science.gov (United States)

    Mosti, Giovanni; Crespi, Aldo; Mattaliano, Vincenzo

    2011-05-01

    Compression therapy is standard treatment for venous leg ulcers. The authors prefer multi-layer, multi-component, stiff, high-pressure bandages to treat venous leg ulcers. The Unna boot (UB) is an example of this type of bandage. The aim of this study was to compare the effectiveness and tolerability of UB to a new, two-component bandage. One hundred (100) patients with venous ulcers were randomized into two groups: group A (n = 50) received UB and group B (n = 50) 3M™ Coban™ 2 Layer Compression System (C2L). All patients were followed weekly for 3 months and then monthly until complete healing was achieved. The primary outcomes were: ulcer healing or surface reduction; pain; and exudate control. The secondary outcomes were: ease of application and removal of the bandage, pressure exerted in the supine and standing position after application and before removal, and bandage comfort. C2L was associated with 100% ulcer healing; 47 out of 50 cases healed within the first 3 months after application of the bandage. Compared with the UB, there was no statistically significant difference. In both groups the effect of compression on pain and overall well being was excellent; pain decreased by 50% within 1-2 weeks and remained low throughout the duration of treatment and overall well being improved significantly. There was no significant difference between the two systems concerning level of comfort. C2L proved to be effective in treating venous ulcers due to its stiffness and pressure. Its effectiveness was similar to UB, which is often considered the gold-standard compression device for venous ulcers. This fact, in combination with high tolerability and ease of application and removal, make this new bandage particularly suitable for the treatment of venous leg ulcers. .

  11. A Faster Algorithm for Computing Straight Skeletons

    KAUST Repository

    Cheng, Siu-Wing

    2014-09-01

    We present a new algorithm for computing the straight skeleton of a polygon. For a polygon with n vertices, among which r are reflex vertices, we give a deterministic algorithm that reduces the straight skeleton computation to a motorcycle graph computation in O(n (logn)logr) time. It improves on the previously best known algorithm for this reduction, which is randomized, and runs in expected O(n√h+1log2n) time for a polygon with h holes. Using known motorcycle graph algorithms, our result yields improved time bounds for computing straight skeletons. In particular, we can compute the straight skeleton of a non-degenerate polygon in O(n (logn) logr + r 4/3 + ε ) time for any ε > 0. On degenerate input, our time bound increases to O(n (logn) logr + r 17/11 + ε ).

  12. A Faster Algorithm for Computing Straight Skeletons

    KAUST Repository

    Mencel, Liam A.

    2014-05-06

    We present a new algorithm for computing the straight skeleton of a polygon. For a polygon with n vertices, among which r are reflex vertices, we give a deterministic algorithm that reduces the straight skeleton computation to a motorcycle graph computation in O(n (log n) log r) time. It improves on the previously best known algorithm for this reduction, which is randomised, and runs in expected O(n √(h+1) log² n) time for a polygon with h holes. Using known motorcycle graph algorithms, our result yields improved time bounds for computing straight skeletons. In particular, we can compute the straight skeleton of a non-degenerate polygon in O(n (log n) log r + r^(4/3 + ε)) time for any ε > 0. On degenerate input, our time bound increases to O(n (log n) log r + r^(17/11 + ε))

  13. SPS, preassembly of short straight sections

    CERN Multimedia

    1975-01-01

    Short straight sections were preassembled with their vacuum chambers, ready for installation in the SPS. Here we see two, containing sextupoles for chromaticity adjustment. See also 7501017, 7501018, and Annual Report 1976, p.174.

  14. SPS, short straight section with sextupole

    CERN Multimedia

    CERN PhotoLab

    1975-01-01

    Short straight sections were preassembled with their vacuum chambers, ready for installation in the SPS. This one contains a sextupole for chromaticity adjustment. See also 7501017, 7501009X, and Annual Report 1974, p.174.

  15. A Faster Algorithm for Computing Straight Skeletons

    KAUST Repository

    Cheng, Siu-Wing; Mencel, Liam A.; Vigneron, Antoine E.

    2014-01-01

    We present a new algorithm for computing the straight skeleton of a polygon. For a polygon with n vertices, among which r are reflex vertices, we give a deterministic algorithm that reduces the straight skeleton computation to a motorcycle graph computation in O(n (logn)logr) time. It improves on the previously best known algorithm for this reduction, which is randomized, and runs in expected O(n√h+1log2n) time for a polygon with h holes. Using known motorcycle graph algorithms, our result yields improved time bounds for computing straight skeletons. In particular, we can compute the straight skeleton of a non-degenerate polygon in O(n (logn) logr + r 4/3 + ε ) time for any ε > 0. On degenerate input, our time bound increases to O(n (logn) logr + r 17/11 + ε ).

  16. The Influence of Video Game Training with and without Subpatelar Bandage in Mobility and Gait Speed on Elderly Female Fallers

    Directory of Open Access Journals (Sweden)

    Isabela Feitosa de Carvalho

    2018-01-01

    Full Text Available Objectives. The aim of the study was to investigate the effect of balance training with Nintendo Wii technology, with and without the use of additional sensory information (subpatellar bandage, in the functional mobility and gait speed of elderly female fallers. Methods. Twenty elderly women were divided into two groups: group I: trained with the use of the Nintendo Wii; group II: trained using the Nintendo Wii and the addition of sensory information (subpatellar bandage. The functional mobility was assessed with the Timed up and Go test (TUG and gait speed with the 10 m test. The tests were carried out with and without the use of the subpatellar bandage. The training was carried out within sessions of 30 minutes, twice a week, using three different games (Penguin Slide, Table Tilt, and Tightrope. Results. There was an increase in the gait speed and a decrease in the TUG time in both groups, independently of the sensory condition used (p<0.05. In the short term, the subpatellar bandage improved the TUG time (p<0.05 and the gait speed (p<0.01. Conclusion. The training for postural balance with virtual reality was effective for improving functional mobility and gait speed of elderly female fallers. The subpatellar bandage did not maximize the effect of training.

  17. The Influence of Video Game Training with and without Subpatelar Bandage in Mobility and Gait Speed on Elderly Female Fallers.

    Science.gov (United States)

    de Carvalho, Isabela Feitosa; Leme, Gianluca Loyolla Montanari; Scheicher, Marcos Eduardo

    2018-01-01

    The aim of the study was to investigate the effect of balance training with Nintendo Wii technology, with and without the use of additional sensory information (subpatellar bandage), in the functional mobility and gait speed of elderly female fallers. Twenty elderly women were divided into two groups: group I: trained with the use of the Nintendo Wii; group II: trained using the Nintendo Wii and the addition of sensory information (subpatellar bandage). The functional mobility was assessed with the Timed up and Go test (TUG) and gait speed with the 10 m test. The tests were carried out with and without the use of the subpatellar bandage. The training was carried out within sessions of 30 minutes, twice a week, using three different games ( Penguin Slide , Table Tilt , and Tightrope ). There was an increase in the gait speed and a decrease in the TUG time in both groups, independently of the sensory condition used ( p < 0.05). In the short term, the subpatellar bandage improved the TUG time ( p < 0.05) and the gait speed ( p < 0.01). The training for postural balance with virtual reality was effective for improving functional mobility and gait speed of elderly female fallers. The subpatellar bandage did not maximize the effect of training.

  18. An investigation of the ability to produce a defined 'target pressure' using the PressCise compression bandage.

    Science.gov (United States)

    Wiklander, Kerstin; Andersson, Annette Erichsen; Källman, Ulrika

    2016-12-01

    Compression therapy is the cornerstone in the prevention and treatment of leg ulcers related to chronic venous insufficiency. The application of optimal high pressure is essential for a successful outcome, but the literature has reported difficulty applying the intended pressure, even among highly skilled nurses. The PressCise bandage has a novel design, with both longitudinal and horizontal reference points for correct application. In the current experimental study, the results for the general linear model, where the data set is treated optimally, showed that all 95% confidence intervals of the expected values for pressure were, at most, 5 mmHg from the target value of 50 mmHg, independent of the position on the leg and the state of activity. Moreover, even nurses with limited experience were consistently able to reach the targeted pressure goal. Future studies are needed to determine how well the bandage works on legs of different shapes, the optimal way of using the bandage (day only or both day and night) and whether the bandage should be combined with an outer bandage layer. In addition, special attention should be paid to subjective patient experiences in relation to the treatment as pain, discomfort and bulk are factors that can compromise patients' willingness to adhere to the treatment protocol and thereby prolong the healing process. © 2015 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  19. Modified tubularized incised plate urethroplasty

    Directory of Open Access Journals (Sweden)

    Shivaji Mane

    2013-01-01

    Full Text Available Aim: To share our experience of doing tubularized incised plate urethroplasty with modifications. Materials and Methods: This is a single surgeon personal series from 2004 to 2009. One hundred patients of distal hypospadias were subjected for Snodgrass urethroplasty with preputioplasty. The age range was 1 to 5 year with mean age of 2.7 years. Selection criteria were good urethral plate, without chordee and torsion needing complete degloving. Main technical modification from original Snodgrass procedure was spongioplasty, preputioplasty, and dorsal slit when inability to retract prepuce during surgery. Results: Average follow-up period is 23 months. Seven (7% patients developed fistula and one patient had complete preputial dehiscence. Phimosis developed in three (3% patients and required circumcision. Dorsal slit was required in seven patients. One patient developed meatal stenosis in postoperative period. All other patients are passing single urinary stream and have cosmesis that is acceptable. Conclusions: Modified tubularized incised plate urethroplasty with preputioplasty effectively gives cosmetically normal looking penis with low complications.

  20. Tubular lining material for pipelines having bends

    Energy Technology Data Exchange (ETDEWEB)

    Moringa, A.; Sakaguchi, Y.; Hyodo, M.; Yagi, I.

    1987-03-24

    A tubular lining material for pipelines having bends or curved portions comprises a tubular textile jacket made of warps and wefts woven in a tubular form overlaid with a coating of a flexible synthetic resin. It is applicable onto the inner surface of a pipeline having bends or curved portions in such manner that the tubular lining material with a binder onto the inner surface thereof is inserted into the pipeline and allowed to advance within the pipeline, with or without the aid of a leading rope-like elongated element, while turning the tubular lining material inside out under fluid pressure. In this manner the tubular lining material is applied onto the inner surface of the pipeline with the binder being interposed between the pipeline and the tubular lining material. The lining material is characterized in that a part of all of the warps are comprised of an elastic yarn around which, over the full length thereof, a synthetic fiber yarn or yarns have been left-and/or right-handedly coiled. This tubular lining material is particularly suitable for lining a pipeline having an inner diameter of 25-200 mm and a plurality of bends, such as gas service pipelines or house pipelines, without occurrence of wrinkles in the lining material in a bend.

  1. Optimization Study of Shaft Tubular Turbine in a Bidirectional Tidal Power Station

    Directory of Open Access Journals (Sweden)

    Xinfeng Ge

    2013-01-01

    Full Text Available The shaft tubular turbine is a form of tidal power station which can provide bidirectional power. Efficiency is an important turbine performance indicator. To study the influence of runner design parameters on efficiency, a complete 3D flow-channel model of a shaft tubular turbine was developed, which contains the turbine runner, guide vanes, and flow passage and was integrated with hybrid grids calculated by steady-state calculation methods. Three aspects of the core component (turbine runner were optimized by numerical simulation. All the results were then verified by experiments. It was shown that curved-edge blades are much better than straight-edge blades; the optimal blade twist angle is 7°, and the optimal distance between the runner and the blades is 0.75–1.25 times the diameter of the runner. Moreover, the numerical simulation results matched the experimental data very well, which also verified the correctness of the optimal results.

  2. Tubular inverse opal scaffolds for biomimetic vessels

    Science.gov (United States)

    Zhao, Ze; Wang, Jie; Lu, Jie; Yu, Yunru; Fu, Fanfan; Wang, Huan; Liu, Yuxiao; Zhao, Yuanjin; Gu, Zhongze

    2016-07-01

    There is a clinical need for tissue-engineered blood vessels that can be used to replace or bypass damaged arteries. The success of such grafts depends strongly on their ability to mimic native arteries; however, currently available artificial vessels are restricted by their complex processing, controversial integrity, or uncontrollable cell location and orientation. Here, we present new tubular scaffolds with specific surface microstructures for structural vessel mimicry. The tubular scaffolds are fabricated by rotationally expanding three-dimensional tubular inverse opals that are replicated from colloidal crystal templates in capillaries. Because of the ordered porous structure of the inverse opals, the expanded tubular scaffolds are imparted with circumferentially oriented elliptical pattern microstructures on their surfaces. It is demonstrated that these tailored tubular scaffolds can effectively make endothelial cells to form an integrated hollow tubular structure on their inner surface and induce smooth muscle cells to form a circumferential orientation on their outer surface. These features of our tubular scaffolds make them highly promising for the construction of biomimetic blood vessels.There is a clinical need for tissue-engineered blood vessels that can be used to replace or bypass damaged arteries. The success of such grafts depends strongly on their ability to mimic native arteries; however, currently available artificial vessels are restricted by their complex processing, controversial integrity, or uncontrollable cell location and orientation. Here, we present new tubular scaffolds with specific surface microstructures for structural vessel mimicry. The tubular scaffolds are fabricated by rotationally expanding three-dimensional tubular inverse opals that are replicated from colloidal crystal templates in capillaries. Because of the ordered porous structure of the inverse opals, the expanded tubular scaffolds are imparted with circumferentially

  3. 78 FR 14361 - U.S. Steel Tubular Products, Inc., Mckeesport Tubular Operations Division, Subsidiary of United...

    Science.gov (United States)

    2013-03-05

    ... Products, Inc., Mckeesport Tubular Operations Division, Subsidiary of United States Steel Corporation, Mckeesport, PA; Notice of Initiation of Investigation To Terminate Certification of Eligibility Pursuant to... Tubular Products, McKeesport Tubular Operations Division, Subsidiary of United States Steel Corporation...

  4. 26 CFR 1.167(b)-1 - Straight line method.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Straight line method. 1.167(b)-1 Section 1.167(b... Straight line method. (a) In general. Under the straight line method the cost or other basis of the... may be reduced to a percentage or fraction. The straight line method may be used in determining a...

  5. The effects of two different types of bandage contact lenses on the healthy canine eye.

    Science.gov (United States)

    Braus, Barbara Katharina; Riedler, Daniela; Tichy, Alexander; Spergser, Joachim; Schwendenwein, Ilse

    2018-02-06

    To compare two types of bandage contact lenses on the healthy canine eye. Six healthy Beagles. Two different types of bandage contact lenses (single sized human silicone contact lens 'PureVision 2' (Bausch & Lomb Incorporated, Rochester, NY, USA) and specially designed veterinary hydrogel contact lens 'AcriVet Pat D' (Bausch & Lomb Incorporated) were placed in 12 eyes of healthy Beagle dogs. Retention times and the effects of the lenses regarding irritation of the eye, changes in tear production, impact of contact lenses on tonometric readings, and cytologic and microbiological alterations of the canine eye were investigated. Mean retention times for veterinary hydrogel lenses with special dimensions were significantly shorter (2 days) than for one size human silicon lenses (8.8 days). Irritation scores were overall low for both types of lenses apart from one human lens causing severe irritation and keratoconjunctivitis as a sequel to folding and displacement. Tear production remained stable in human contact lenses. Intraocular pressure readings with a contact lens in place were only slightly altered; the most accurate readings were obtained through a human lens with an applanation tonometer. Cytology revealed a slight, nonsignificant increase in neutrophilic granulocytes with both types of lenses; the microflora did not change significantly. Human silicone lenses have significantly longer retention times and are less expensive than veterinary hydrogel lenses. In regard to irritation, bacterial growth and inflammation, both types of lenses can be recommended for use in canine eyes. © 2018 American College of Veterinary Ophthalmologists.

  6. Straight line closure of congenital macrostomia

    Directory of Open Access Journals (Sweden)

    Schwarz Richard

    2004-01-01

    Full Text Available The results of patients operated on by Nepal Cleft Lip and Palate Association (NECLAPA surgeons for congenital macrostomia were prospectively studied between January 2000 and December 2002. There were four males and three females with a median age of 10 years. Three had an associated branchial arch syndrome. In all patients an overlapping repair of orbicularis oris was done. Six patients had a straight line closure with excellent cosmetic results and one a Z-plasty with a more obvious scar. All had a normal appearing commissure. Overlapping orbicularis repair with straight line skin closure for this rare congenital anomaly is recommended.

  7. Tubular bioreactor and its application; Tubular bioreactor to sono tekiyo

    Energy Technology Data Exchange (ETDEWEB)

    Endo, I.; Nagamune, T. [The University of Tokyo, Tokyo (Japan). Faculty of Engineering; Yuki, K. [Nikka Whisky Distilling Co. Ltd. Tokyo (Japan); Inaba, H. [Sumitomo Heavy Industries, Ltd., Tokyo (Japan)

    1994-09-05

    The loop type tubular bioreactor (TBR) was developed where biocatalysts are trapped in the reactor by membrane module. A UF membrane or MF membrane and crossflow filtration were adopted for the membrane module, and the reactor loop was composed of four membrane modules. The reactor was operated at 2-4 m/s in membrane surface velocity and 300-400 kPa in filtration pressure. As the result of the high-density culture of lactic acid bacteria and yeast, a biomass concentration was more than 10 times that in batch culture, suggesting the remarkable enhancement of a production efficiency. As the result of the continuous fermentation of cider, the fast fermentation more than 60 times that in conventional ones was obtained together with the same quality as conventional ones. Such a fast fermentation was probably achieved by yeast suspended in the fermenter of TBR, by yeast hardly affected physico-chemically as compared with immobilized reactors, and by small effect of mass transfer on reaction systems. 4 refs., 6 figs.

  8. Proximal tubular hypertrophy and enlarged glomerular and proximal tubular urinary space in obese subjects with proteinuria.

    Directory of Open Access Journals (Sweden)

    Ana Tobar

    Full Text Available BACKGROUND: Obesity is associated with glomerular hyperfiltration, increased proximal tubular sodium reabsorption, glomerular enlargement and renal hypertrophy. A single experimental study reported an increased glomerular urinary space in obese dogs. Whether proximal tubular volume is increased in obese subjects and whether their glomerular and tubular urinary spaces are enlarged is unknown. OBJECTIVE: To determine whether proximal tubules and glomerular and tubular urinary space are enlarged in obese subjects with proteinuria and glomerular hyperfiltration. METHODS: Kidney biopsies from 11 non-diabetic obese with proteinuria and 14 non-diabetic lean patients with a creatinine clearance above 50 ml/min and with mild or no interstitial fibrosis were retrospectively analyzed using morphometric methods. The cross-sectional area of the proximal tubular epithelium and lumen, the volume of the glomerular tuft and of Bowman's space and the nuclei number per tubular profile were estimated. RESULTS: Creatinine clearance was higher in the obese than in the lean group (P=0.03. Proteinuria was similarly increased in both groups. Compared to the lean group, the obese group displayed a 104% higher glomerular tuft volume (P=0.001, a 94% higher Bowman's space volume (P=0.003, a 33% higher cross-sectional area of the proximal tubular epithelium (P=0.02 and a 54% higher cross-sectional area of the proximal tubular lumen (P=0.01. The nuclei number per proximal tubular profile was similar in both groups, suggesting that the increase in tubular volume is due to hypertrophy and not to hyperplasia. CONCLUSIONS: Obesity-related glomerular hyperfiltration is associated with proximal tubular epithelial hypertrophy and increased glomerular and tubular urinary space volume in subjects with proteinuria. The expanded glomerular and urinary space is probably a direct consequence of glomerular hyperfiltration. These effects may be involved in the pathogenesis of obesity

  9. [Heel pressure ulcers. Comparative study between heel protective bandage and hydrocellular dressing with special form for the heel].

    Science.gov (United States)

    Torra i Bou, Joan-Enric; Rueda López, Justo; Camañes, Gemma; Herrero Narváez, Elias; Blanco Blanco, Joan; Martínez-Esparza, Elvira Hernández; Aneas Alcántara, Jesús; Verdú Soriano, José

    2002-05-01

    The heels, together with the sacra area, are one of the most frequent spots where pressure sores appear here in Spain. Any preventive measure against pressure sores on heels needs be oriented towards two main objectives: effective relief of pressure and its compatibility with localized care and skin inspection in order to detect lesions early on at least once a day. The authors planned a comparative, multi-centered, open, labeled and controlled study in which patients were assigned to two groups receiving these treatments: one received traditional preventive pressure sore treatment and a protective bandage on their heels while the other used a special Allevyn Heel hydrocellular dressing to protect their heels. The patients took part in this study over an eight week period. The response variable used to determine the effectiveness of the preventive measure in this study was the appearance of pressure sores. At the beginning, 130 patients were included in this study, 65 in each one of the treatment groups. In the bandage group, 50 patients finished this study while 61 in the dressing group finished this study. The appearance of pressure sores in the protective bandage group occurred in 44% of the patients, 22 out of 50, while in the dressing group, the occurrence rate was 3.3%, 2 out of 61 patients with a value of "ji" squared p pressure sore brought us a value of relative risk of 13.42 (IC 95%: 3.31-54.3) in the group wearing the protective bandage compared to the group wearing the dressing. The results of this study allow us to accept as valid the alternate hypothesis that there exist significant statistical differences between both treatment methods in favor of the Allevyn Heel dressing instead of the protective heel bandage. The use of this dressing, even though it is more expensive a priori than the protective bandage, in terms of unit cost for the product, has proven to be more effective in preventing pressure sores, and cheaper than the protective bandage if

  10. An intersection graph of straight lines

    DEFF Research Database (Denmark)

    Thomassen, Carsten

    2002-01-01

    G. Ehrlich, S. Even, and R.E. Tarjan conjectured that the graph obtained from a complete 3 partite graph K4,4,4 by deleting the edges of four disjoint triangles is not the intersection graph of straight line segments in the plane. We show that it is....

  11. Beam line from straight-section 16

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    The start of a long trail. The beam line from straight-section 16, where protons are fast ejected, is seen at the point where it crosses the Linac shielding wall as it leaves the PS en route to the ISR.

  12. Iatrogenic Digital Compromise with Tubular Dressings

    Directory of Open Access Journals (Sweden)

    Corre, Kenneth A

    2009-08-01

    Full Text Available Objective: This case report describes a digit amputation resulting from an improperly applied tubular dressing. The safe application of digital tubular dressings, and the rationale behind it, is detailed to raise emergency physician (EP awareness.Methods: We present a case report of a recent iatrogenic-induced digit ischemia caused by improperly applied tube gauze. We review the literature on the subject and the likely sources of poor outcomes presented. The proper application of tubular gauze dressings is then outlined.Conclusion: EPs and emergency department personnel must be educated on the safe application of tubular gauze dressings to avoid dire outcomes associated with improper applications.[WestJEM. 2009;10:190-192.

  13. Renal Tubular Function in Systemic Lupus Erythematosus*

    African Journals Online (AJOL)

    immune' diseases such as. Sjogren's syndrome,'" systemic lupus erythematosus. (SLE),3 alveolitis' and chronic active hepatitis.' The reported abnormalities of renal tubular function include impairment of acid excretion and urinary concentration.

  14. A neglected case of Renal Tubular Acidosis

    International Nuclear Information System (INIS)

    Derakhshan, A.; Basiratnia, M.; Fallahzadeh, M.H.; Al-Hashemi, G.H.

    2007-01-01

    In this report, we present a case of a child with distal renal tubular acidosis, severe failure to thrive and profound rickets, who was only 7.8 Kg when presented at 6 years of age. His response to treatment and his follow up for four years is discussed. Although failure to thrive is a common finding in renal tubular acidosis but the physical and x-ray findings in our case were unique. (author)

  15. Evaluation of the safety and efficacy of therapeutic bandage contact lenses on post-cataract surgery patients.

    Science.gov (United States)

    Shi, Dan-Na; Song, Hang; Ding, Tong; Qiu, Wei-Qiang; Wang, Wei

    2018-01-01

    To evaluate the safety of therapeutic bandage contact lens for post-cataract surgery patients and to illustrate its efficacy on post-operative comfort and tear-film stability. A total of 40 participants were recruited and randomly divided into two groups. Group one was instructed to wear bandage contact lenses for a week and use antibiotic eye drops for a month since the first day after surgery. Group two received sub-conjunctival injection of tobramycin and was asked to wear eye pads on the first day after surgery and then were instructed to use antibiotic eye drops as the first group did. Ocular surface disease index (OSDI) questionnaire, slit-lamp microscope examination of tear break-up time (TBUT), corneal fluorescein score (CFS), tear meniscus height (TMH) together with anterior segment optical coherence tomography (AS-OCT) and corneal topography were evaluated preoperatively and postoperatively. The subjective feeling ( P =0.004), TBUT ( P <0.001) and TMH ( P =0.02) post-surgery had improved in patients who used bandage contact lenses compared with those who did not at 1wk post-surgery. Until three month postoperatively, the comfort degree ( P =0.004) and TMH ( P =0.01) of group two were still worse than group one. Moreover, TBUT ( P <0.001) and CFS ( P =0.004) of the group with eye pads got worse than the results before, whereas the group with bandage contact lenses recovered to normal. None of these patients had infections or other complications. Wearing therapeutic bandage contact lens after cataract surgery, compared with traditional eye-pads, is a safe method to improve tear-film stability and reduce post-operative discomfort without hindering corneal incision recovery.

  16. Non-invasive transdermal two-dimensional mapping of cutaneous oxygenation with a rapid-drying liquid bandage.

    Science.gov (United States)

    Li, Zongxi; Roussakis, Emmanuel; Koolen, Pieter G L; Ibrahim, Ahmed M S; Kim, Kuylhee; Rose, Lloyd F; Wu, Jesse; Nichols, Alexander J; Baek, Yunjung; Birngruber, Reginald; Apiou-Sbirlea, Gabriela; Matyal, Robina; Huang, Thomas; Chan, Rodney; Lin, Samuel J; Evans, Conor L

    2014-11-01

    Oxygen plays an important role in wound healing, as it is essential to biological functions such as cell proliferation, immune responses and collagen synthesis. Poor oxygenation is directly associated with the development of chronic ischemic wounds, which affect more than 6 million people each year in the United States alone at an estimated cost of $25 billion. Knowledge of oxygenation status is also important in the management of burns and skin grafts, as well as in a wide range of skin conditions. Despite the importance of the clinical determination of tissue oxygenation, there is a lack of rapid, user-friendly and quantitative diagnostic tools that allow for non-disruptive, continuous monitoring of oxygen content across large areas of skin and wounds to guide care and therapeutic decisions. In this work, we describe a sensitive, colorimetric, oxygen-sensing paint-on bandage for two-dimensional mapping of tissue oxygenation in skin, burns, and skin grafts. By embedding both an oxygen-sensing porphyrin-dendrimer phosphor and a reference dye in a liquid bandage matrix, we have created a liquid bandage that can be painted onto the skin surface and dries into a thin film that adheres tightly to the skin or wound topology. When captured by a camera-based imaging device, the oxygen-dependent phosphorescence emission of the bandage can be used to quantify and map both the pO2 and oxygen consumption of the underlying tissue. In this proof-of-principle study, we first demonstrate our system on a rat ischemic limb model to show its capabilities in sensing tissue ischemia. It is then tested on both ex vivo and in vivo porcine burn models to monitor the progression of burn injuries. Lastly, the bandage is applied to an in vivo porcine graft model for monitoring the integration of full- and partial-thickness skin grafts.

  17. Influence of Elastic Bandage and Neoprene Sleeve on Knee Position Sense and Pain in Subjects with Knee Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Basir Majdoleslami

    2003-12-01

    Full Text Available Objective: to investigate whether a neoprene sleeve and elastic bandage around the knee joint of subjects with knee osteoarthritis (OA would , in short term (a reduce pain (b improve knee joint position sense and comparison of their effect with each other if they have. Materials & Methods: In a semi-experimental study, 30 subjects (11 men, 19 women, age between 33-75 with unilateral knee OA. Subjects had to have at least 2cm from 10cm visual analogue scale (VAS of knee pain for study entry.All patients were randomly assigned to either an elastic bandage or a neoprene sleeve. One week later they were assigned to the opposite selection. Joint position sense was assessed in the sitting position using an electrogoniometer and pain by VAS where 0cm equals no pain and 10 cm equals worst pain. Knee pain and JPS were assessed for each selection one week apart. During each visit assessment were performed at baseline and after 20 min of bandage/neoprene sleeve application. Results: the mean of scores for knee variables JPS and VAS was taken and paired-t test and Wilcoxon signed rank test was employed to calculate the different between two trails. Neoprene sleeve had significant effect on knee JPS (P=0.037. But elastic bandage had no effect (P=0.631. Both of them had significantly reduced knee pain. (P=0.000 Conclusion: In subjects with both neoprene sleeve and elastic bandage reduced knee pain with more effect of neoprene sleeve. Only the neoprene sleeve had effect on knee JPS.

  18. Evaluation of the safety and efficacy of therapeutic bandage contact lenses on post-cataract surgery patients

    Directory of Open Access Journals (Sweden)

    Dan-Na Shi

    2018-02-01

    Full Text Available AIM: To evaluate the safety of therapeutic bandage contact lens for post-cataract surgery patients and to illustrate its efficacy on post-operative comfort and tear-film stability. METHODS: A total of 40 participants were recruited and randomly divided into two groups. Group one was instructed to wear bandage contact lenses for a week and use antibiotic eye drops for a month since the first day after surgery. Group two received sub-conjunctival injection of tobramycin and was asked to wear eye pads on the first day after surgery and then were instructed to use antibiotic eye drops as the first group did. Ocular surface disease index (OSDI questionnaire, slit-lamp microscope examination of tear break-up time (TBUT, corneal fluorescein score (CFS, tear meniscus height (TMH together with anterior segment optical coherence tomography (AS-OCT and corneal topography were evaluated preoperatively and postoperatively. RESULTS: The subjective feeling (P=0.004, TBUT (P<0.001 and TMH (P=0.02 post-surgery had improved in patients who used bandage contact lenses compared with those who did not at 1wk post-surgery. Until three month postoperatively, the comfort degree (P=0.004 and TMH (P=0.01 of group two were still worse than group one. Moreover, TBUT (P<0.001 and CFS (P=0.004 of the group with eye pads got worse than the results before, whereas the group with bandage contact lenses recovered to normal. None of these patients had infections or other complications. CONCLUSION: Wearing therapeutic bandage contact lens after cataract surgery, compared with traditional eye-pads, is a safe method to improve tear-film stability and reduce post-operative discomfort without hindering corneal incision recovery.

  19. Urinary loss of glucose, phosphate, and protein by diffusion into proximal straight tubules injured by D-serine and maleic acid

    International Nuclear Information System (INIS)

    Carone, F.A.; Nakamura, S.; Goldman, B.

    1985-01-01

    In several models of acute renal failure leakage of glomerular filtrate out of the tubule is an important pathogenetic mechanism; however, bidirectional diffusion of solute to account for certain pathophysiologic features of acute renal failure has received meager attention. Using micropuncture and clearance methods, the authors assessed sequentially leakage of solutes and inulin across proximal straight tubules (PST) injured by two nephrotoxins. In d-serine-treated rats with extensive necrosis of PST, the basis for glucosuria and tubular leakage of inulin was studied. Glucose absorption by the proximal convoluted tubule and glucose delivery to the PST were normal, but glucose delivery to the distal tubule was increased nearly 8-fold, indicating diffusion of glucose from interstitial to tubular luminal fluid across the necrotic PST. Total kidney inulin clearance was greatly reduced, but single nephron glomerular filtration rate, based on proximal convoluted tubule samples, was normal, indicating tubular loss of inulin. Urinary recovery of [ 14 C]inulin infused into tubular lumina revealed that proximal convoluted tubule and distal tubule were impermeable to inulin and that inulin diffused out of the necrotic PST. The progressive return over 6 days of tubular impermeability for inulin correlated with relining of PST with new cells. In maleic acid-treated rats the site and extent of tubular necrosis and the nature of urinary loss of solutes were studied. Microdissection revealed that maleic acid caused limited necrosis of PST which averaged 7.4% of total proximal tubular length. Increased urinary excretion of protein, phosphate, and glucose and increased tubular permeability to microinfused [ 14 C]inulin occurred with the onset of PST necrosis, and return of these abnormalities to normal correlated with the degree of cellular repair of the PST

  20. Rocket-inspired tubular catalytic microjets with grating-structured walls as guiding empennages.

    Science.gov (United States)

    Huang, Gaoshan; Wang, Jiyuan; Liu, Zhaoqian; Zhou, Dekai; Tian, Ziao; Xu, Borui; Li, Longqiu; Mei, Yongfeng

    2017-12-07

    Controllable locomotion in the micro-/nanoscale is challenging and attracts increasing research interest. Tubular microjets self-propelled by microbubbles are intensively investigated due to their high energy conversion efficiency, but the imperfection of the tubular geometry makes it harder to realize linear motion. Inspired by the macro rocket, we designed a tubular microjet with a grating-structured wall which mimics the guiding empennage of the macro rocket, and we found that the fluid can be effectively guided by the grooves. Both theoretical simulation and experimental work have been carried out, and the obtained results demonstrate that the stability margin of the grating-structured microjet can be enhanced. Compared with microjets with smooth walls, the structured microjets show an enhanced ability of moving linearly. In 10% H 2 O 2 , only 20% of the smooth microjets demonstrate linear trajectories, while 80% of the grating-structured microjets keep moving straight. The grating-structured microjet can maintain linear motion under external disturbance. We further propose to increase the stability by introducing a helical grating structure.

  1. FIXTURING DEVICE FOR DRILLING A STRAIGHT SHAFT

    Directory of Open Access Journals (Sweden)

    SUSAC, Florin

    2017-05-01

    Full Text Available The paper presents a fixturing device used for machining by drilling a straight shaft. The shaft was manufactured on EMCO CONCEPT TURN 55 CNC. The blank used was a bar with circular cross-section. The orientation and fixing scheme of the part and the orientation elements for fixturing device are presented as they were drawn in Autodesk Inventor and AutoCAD software.

  2. Straight-line string with curvature

    International Nuclear Information System (INIS)

    Solov'ev, L.D.

    1995-01-01

    Classical and quantum solutions for the relativistic straight-line string with arbitrary dependence on the world surface curvature are obtained. They differ from the case of the usual Nambu-Goto interaction by the behaviour of the Regge trajectory which in general can be non-linear. A regularization of the action is considered and a comparison with relativistic point with curvature is made. 5 refs

  3. Straight, white teeth as a social prerogative.

    Science.gov (United States)

    Khalid, Abeer; Quiñonez, Carlos

    2015-06-01

    A distinguishing feature of North American society is preoccupation with self-image, as seen in the ritualistic nature of bodily practices aimed at constantly improving the body. Nowhere is this more apparent than in the prevailing fixation with straight, white teeth. While there is an ever-expanding literature on the sociology of body, very little has been written on teeth in this context. Using literature from anthropology, biology, dentistry, sociology and social psychology, this study attempts to answer: (1) Why have straight, white teeth become a beauty ideal in North American society? (2) What is the basis for this ideal? (3) How is this ideal propagated? It demonstrates that dental aesthetic tendencies are biologically, culturally and socially patterned. Concepts from the works of Pierre Bourdieu and Michel Foucault are used to illustrate how straight, white teeth contribute towards reinforcing class differences and how society exercises a disciplinary power on individuals through this ideal. It is concluded that modified teeth are linked to self and identity that are rooted in social structure. Moreover, teeth demonstrate the ways in which class differences are embodied and projected as symbols of social advantage or disadvantage. Implications on professional, public health, sociological and political levels are considered. © 2015 Foundation for the Sociology of Health & Illness.

  4. Straight until proven gay: A systematic bias toward straight categorizations in sexual orientation judgments.

    Science.gov (United States)

    Lick, David J; Johnson, Kerri L

    2016-06-01

    Perceivers achieve above chance accuracy judging others' sexual orientations, but they also exhibit a notable response bias by categorizing most targets as straight rather than gay. Although a straight categorization bias is evident in many published reports, it has never been the focus of systematic inquiry. The current studies therefore document this bias and test the mechanisms that produce it. Studies 1-3 revealed the straight categorization bias cannot be explained entirely by perceivers' attempts to match categorizations to the number of gay targets in a stimulus set. Although perceivers were somewhat sensitive to base rate information, their tendency to categorize targets as straight persisted when they believed each target had a 50% chance of being gay (Study 1), received explicit information about the base rate of gay targets in a stimulus set (Study 2), and encountered stimulus sets with varying base rates of gay targets (Study 3). The remaining studies tested an alternate mechanism for the bias based upon perceivers' use of gender heuristics when judging sexual orientation. Specifically, Study 4 revealed the range of gendered cues compelling gay judgments is smaller than the range of gendered cues compelling straight judgments despite participants' acknowledgment of equal base rates for gay and straight targets. Study 5 highlighted perceptual experience as a cause of this imbalance: Exposing perceivers to hyper-gendered faces (e.g., masculine men) expanded the range of gendered cues compelling gay categorizations. Study 6 linked this observation to our initial studies by demonstrating that visual exposure to hyper-gendered faces reduced the magnitude of the straight categorization bias. Collectively, these studies provide systematic evidence of a response bias in sexual orientation categorization and offer new insights into the mechanisms that produce it. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  5. Thermal CFD Analysis of Tubular Light Guides

    Directory of Open Access Journals (Sweden)

    Ondřej Šikula

    2013-12-01

    Full Text Available Tubular light guides are applicable for daylighting of windowless areas in buildings. Despite their many positive indoor climate aspects they can also present some problems with heat losses and condensation. A computer CFD model focused on the evaluation of temperature distribution and air flow inside tubular light guides of different dimensions was studied. The physical model of the tested light guides of lengths more than 0.60 m proves shows that Rayleigh numbers are adequate for a turbulent air flow. The turbulent model was applied despite the small heat flux differences between the turbulent and laminar model. The CFD simulations resulted into conclusions that the growing ratio of length/diameter increases the heat transmission loss/linear transmittance as much as by 50 percent. Tubular light guides of smaller diameters have lower heat transmission losses compared to the wider ones of the same lengths with the same outdoor temperature being taken into account. The simulation results confirmed the thermal bridge effect of the tubular light guide tube inside the insulated flat roof details. The thermal transmittance of the studied light guides in the whole roof area was substituted with the point thermal bridges. This substitution gives possibility for simple thermal evaluation of the tubular light pipes in roof constructions.

  6. 21 CFR 82.5 - General specifications for straight colors.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false General specifications for straight colors. 82.5... LISTING OF CERTIFIED PROVISIONALLY LISTED COLORS AND SPECIFICATIONS General Provisions § 82.5 General specifications for straight colors. No batch of a straight color listed in subpart B, C, or D shall be certified...

  7. 14 CFR 417.215 - Straight-up time analysis.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Straight-up time analysis. 417.215 Section..., DEPARTMENT OF TRANSPORTATION LICENSING LAUNCH SAFETY Flight Safety Analysis § 417.215 Straight-up time analysis. A flight safety analysis must establish the straight-up time for a launch for use as a flight...

  8. Straight and White: Talking with My Mouth Full

    Science.gov (United States)

    Myers, W. Benjamin

    2008-01-01

    By using straight and white teeth as a metaphor for a straight and White identity, the author reflects on how this identity is performed, maintained, and often problematic. Using literature about identity performance, three different voices speak to and from straight and White identity. Using irony by blending arrogance and ignorance in the voice…

  9. 7 CFR 29.6128 - Straight Stripped (X Group).

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Straight Stripped (X Group). 29.6128 Section 29.6128... REGULATIONS TOBACCO INSPECTION Standards Grades § 29.6128 Straight Stripped (X Group). This group consists of..., and tolerances X1 Fine Quality Straight Stripped. Heavy, ripe, firm, semielastic, normal strength and...

  10. [Quality of self-applied compression bandages in patients with chronic venous ulcers : Results of a prospective clinical study].

    Science.gov (United States)

    Stoffels-Weindorf, M; Stoffels, I; Jockenhöfer, F; Dissemond, J

    2018-04-01

    For effective compression therapy in patients with venous leg ulcers, sufficient pressure is essential. In everyday life, it is often the patients themselves who apply the compression bandages. Many of these patients have restriction in their movement and had been rarely trained adequately. Hence, there was the question of how efficient are the autonomously applied compression bandages of those patients. In all, 100 consecutive patients with venous leg ulcer were asked to apply compression bandages on their own leg. We documented both the achieved compression and formal criteria of correct performance. A total of 59 women and 41 men with an average age of 70.3 years were included in the study. Overall 43 patients were not able to apply a compression bandage because of physical limitations. The measured pressure values in the remaining 57 patients ranged between 6 and 93 mm Hg (mean 28.3 mm Hg). Eleven patients reached the prescribed effective compression pressure. Of these, formal errors were found in 6 patients, so that only 5 patients had correctly applied the compression bandages. Our data show that most patients with venous leg ulcers are not able to apply effective compression therapy with short-stretch bandages to themselves. Multilayer systems, adaptive compression bandages, and ulcer stocking systems today are possibly easier and more effective therapy options. Alternatively short-stretch bandages could be applied by trained persons but only under the control with pressure measuring probes.

  11. In search of optimal compression therapy for venous leg ulcers: a meta-analysis of studies comparing diverse [corrected] bandages with specifically designed stockings.

    Science.gov (United States)

    Amsler, Felix; Willenberg, Torsten; Blättler, Werner

    2009-09-01

    In search of an optimal compression therapy for venous leg ulcers, a systematic review and meta-analysis was performed of randomized controlled trials (RCT) comparing compression systems based on stockings (MCS) with divers bandages. RCT were retrieved from six sources and reviewed independently. The primary endpoint, completion of healing within a defined time frame, and the secondary endpoints, time to healing, and pain were entered into a meta-analysis using the tools of the Cochrane Collaboration. Additional subjective endpoints were summarized. Eight RCT (published 1985-2008) fulfilled the predefined criteria. Data presentation was adequate and showed moderate heterogeneity. The studies included 692 patients (21-178/study, mean age 61 years, 56% women). Analyzed were 688 ulcerated legs, present for 1 week to 9 years, sizing 1 to 210 cm(2). The observation period ranged from 12 to 78 weeks. Patient and ulcer characteristics were evenly distributed in three studies, favored the stocking groups in four, and the bandage group in one. Data on the pressure exerted by stockings and bandages were reported in seven and two studies, amounting to 31-56 and 27-49 mm Hg, respectively. The proportion of ulcers healed was greater with stockings than with bandages (62.7% vs 46.6%; P bandages better than MCS. Pain was assessed in three studies (219 patients) revealing an important advantage of stockings (P bandages, has a positive impact on pain, and is easier to use.

  12. Transition piece for joining together tubular pieces

    International Nuclear Information System (INIS)

    Holko, K.H.

    1981-01-01

    A transition piece for joining together tubular pieces formed respectively from a low alloy or carbon steel and a high temperature alloy containing at least 16% chromium includes a plurality of tubular parts welded together and formed from materials of selected composition with a maximum chromium content difference of 5% between adjacent parts when the chromium content of each part is below 10% and a maximum chromium difference of 7% between adjacent parts when the chromium content of either part is above 10%. The transition parts are also graded as to such characteristics as thermal expansion coefficient. The transition parts at opposite ends of the transition joint have chromium percentages similar to the tubular pieces to which they are to be joined. The parts may be joined by fusion and/or friction welding and parts may be formed by fusion weld deposition. (author)

  13. Fatal pulmonary embolism subsequent to the use of Esmarch bandage and tourniquet: A case report and review of literature

    Directory of Open Access Journals (Sweden)

    Sameer Desai

    2013-01-01

    Full Text Available We report a case of fatal pulmonary embolism (PE following exsanguinations of lower limb in orthopedic surgery. A 30-year-old man was posted for fixation of a tibial plateau fracture on the seventh day after injury. Subarchnoid block was performed. Esmarch bandage was used for exsanguination of the limb and tourniquet was inflated. Within three minutes after tourniquet inflation, the patient became unconscious hypotensive, and collapsed. Resuscitation was instituted and spontaneous circulation restored. Right ventricular strain pattern on transthoracic echocardiography, increased levels of D-dimer, and Doppler examination of the lowerlimb confirmed deep venous thrombosis of right femoral vessels and PE. In spite of thrombolytic therapy with streptokinase and heparin, the patient died on the ninth day after the event. Cases of PE secondary to the use of Esmarch bandage and tourniquet are reviewed here to identify the risk groups and management of PE.

  14. Tubular membrane bioreactors for biotechnological processes.

    Science.gov (United States)

    Wolff, Christoph; Beutel, Sascha; Scheper, Thomas

    2013-02-01

    This article is an overview of bioreactors using tubular membranes such as hollow fibers or ceramic capillaries for cultivation processes. This diverse group of bioreactor is described here in regard to the membrane materials used, operational modes, and configurations. The typical advantages of this kind of system such as environments with low shear stress together with high cell densities and also disadvantages like poor oxygen supply are summed up. As the usage of tubular membrane bioreactors is not restricted to a certain organism, a brief overview of various applications covering nearly all types of cells from prokaryotic to eukaryotic cells is also given here.

  15. Tubular manipulators: a new concept for intracochlear positioning of an auditory prosthesis

    Directory of Open Access Journals (Sweden)

    Rau Thomas S.

    2015-09-01

    Full Text Available The aim of this study was to investigate the applicability of tubular manipulators as an actuator mechanism for intracochlear positioning of the electrode array (EA of a cochlear implant (CI. This is motivated by the vision of an atraumatic insertion of the EA into the inner ear (cochlea without any damage to the intracochlear structures in combination with a well-defined final position. To realize this, an actuator mechanism is required which allows consideration of the patient-specific anatomy. We propose a tubular manipulator for this task. It consists of three concentric tubes: A straight outer tube serves as a guiding sleeve to enter the inner ear (cochlea and two additional telescoping, superelastic, helically precurved tubes. By selecting helical tube parameters of both tubes prior insertion, a patient-specific curling behaviour of the tubular manipulator can be achieved. For preliminary investigation, segmentation and skeletonization of 5 human scala tympani were performed to determine their centrelines. These centrelines were considered as individual ideal insertion paths. An optimization algorithm was developed to identify suitable tube set parameters (curvature, diameter, length, torsion, stiffness as well as configuration parameters (translation and rotation of the 2 inner tubes. Different error values describing the deviation of the shape of the tubes with respect to the insertion path were used to quantify the optimization results. In all cases tube set parameters for a final position within the cochlea were found, while keeping the maximum error below 1mm. These preliminary results are promising in terms of the potential applicability of tubular manipulators for positioning auditory prosthesis inside the scala tympani of the inner ear.

  16. Antimicrobial Properties of Diamond-Like Carbon/Silver Nanocomposite Thin Films Deposited on Textiles: Towards Smart Bandages

    Directory of Open Access Journals (Sweden)

    Tadas Juknius

    2016-05-01

    Full Text Available In the current work, a new antibacterial bandage was proposed where diamond-like carbon with silver nanoparticle (DLC:Ag-coated synthetic silk tissue was used as a building block. The DLC:Ag structure, the dimensions of nanoparticles, the silver concentration and the silver ion release were studied systematically employing scanning electron microscopy, energy dispersive X-ray spectroscopy and atomic absorption spectroscopy, respectively. Antimicrobial properties were investigated using microbiological tests (disk diffusion method and spread-plate technique. The DLC:Ag layer was stabilized on the surface of the bandage using a thin layer of medical grade gelatin and cellulose. Four different strains of Staphylococcus aureus extracted from humans’ and animals’ infected wounds were used. It is demonstrated that the efficiency of the Ag+ ion release to the aqueous media can be increased by further RF oxygen plasma etching of the nanocomposite. It was obtained that the best antibacterial properties were demonstrated by the plasma-processed DLC:Ag layer having a 3.12 at % Ag surface concentration with the dominating linear dimensions of nanoparticles being 23.7 nm. An extra protective layer made from cellulose and gelatin with agar contributed to the accumulation and efficient release of silver ions to the aqueous media, increasing bandage antimicrobial efficiency up to 50% as compared to the single DLC:Ag layer on textile.

  17. Clinical observation on bandage type corneal contact lens applied after pterygium excision combined with fresh amniotic membrane transplantation

    Directory of Open Access Journals (Sweden)

    Bin Zhang

    2018-04-01

    Full Text Available AIM: To evaluate the clinical effect of fresh amniotic membrane transplantation in combination with bandage type corneal contact lens in the treatment of pterygium. METHODS: This study was a prospective analysis of 600 pterygium excision patients(600 cases, 600 eyesin the He Eye Hospital from January 2016 to June 2016. The patients were randomly and evenly divided into two groups: observation group and control group, 300 cases in each group(300 eyes. Observation group wore the bandage type corneal contact lens after surgery and took it down at fifth day. The control group did not. The degree of pain after surgery were evaluated at 2h, 1, 3 and 5d after surgery. The clinical outcomes in these two groups were compared in a 12mo postoperative follow-up observation. RESULTS: There were no significant differences between the observation and control group in the percentage of age and gender and size of the pterygium(P>0.05. After surgery, the degree of pain of treatment group significantly decreased compared to control group, the difference was statistically significant(PP>0.05. CONCLUSION: Bandage contact lenses could significantly release pain response after pterygium excision. But it can not reduce the recurrence rate.

  18. Antimicrobial Properties of Diamond-Like Carbon/Silver Nanocomposite Thin Films Deposited on Textiles: Towards Smart Bandages

    Science.gov (United States)

    Juknius, Tadas; Ružauskas, Modestas; Tamulevičius, Tomas; Šiugždinienė, Rita; Juknienė, Indrė; Vasiliauskas, Andrius; Jurkevičiūtė, Aušrinė; Tamulevičius, Sigitas

    2016-01-01

    In the current work, a new antibacterial bandage was proposed where diamond-like carbon with silver nanoparticle (DLC:Ag)-coated synthetic silk tissue was used as a building block. The DLC:Ag structure, the dimensions of nanoparticles, the silver concentration and the silver ion release were studied systematically employing scanning electron microscopy, energy dispersive X-ray spectroscopy and atomic absorption spectroscopy, respectively. Antimicrobial properties were investigated using microbiological tests (disk diffusion method and spread-plate technique). The DLC:Ag layer was stabilized on the surface of the bandage using a thin layer of medical grade gelatin and cellulose. Four different strains of Staphylococcus aureus extracted from humans’ and animals’ infected wounds were used. It is demonstrated that the efficiency of the Ag+ ion release to the aqueous media can be increased by further RF oxygen plasma etching of the nanocomposite. It was obtained that the best antibacterial properties were demonstrated by the plasma-processed DLC:Ag layer having a 3.12 at % Ag surface concentration with the dominating linear dimensions of nanoparticles being 23.7 nm. An extra protective layer made from cellulose and gelatin with agar contributed to the accumulation and efficient release of silver ions to the aqueous media, increasing bandage antimicrobial efficiency up to 50% as compared to the single DLC:Ag layer on textile. PMID:28773494

  19. New airfoil sections for straight bladed turbine

    Science.gov (United States)

    Boumaza, B.

    1987-07-01

    A theoretical investigation of aerodynamic performance for vertical axis Darrieus wind turbine with new airfoils sections is carried out. The blade section aerodynamics characteristics are determined from turbomachines cascade model. The model is also adapted to the vertical Darrieus turbine for the performance prediction of the machine. In order to choose appropriate value of zero-lift-drag coefficient in calculation, an analytical expression is introduced as function of chord-radius ratio and Reynolds numbers. New airfoils sections are proposed and analyzed for straight-bladed turbine.

  20. New airfoil sections for straight bladed turbine

    International Nuclear Information System (INIS)

    Boumaza, B.

    1987-07-01

    A theoretical investigation of aerodynamic performance for vertical axis Darrieus wind turbine with new airfoils sections is carried out. The blade section aerodynamics characteristics are determined from turbomachines cascade model. The model is also adapted to the vertical Darrieus turbine for the performance prediction of the machine. In order to choose appropriate value of zero-lift-drag coefficient in calculation, an analytical expression is introduced as function of chord-radius ratio and Reynolds numbers. New airfoils sections are proposed and analyzed for straight-bladed turbine

  1. Subjective Straight Ahead Orientation in Microgravity

    Science.gov (United States)

    Clement, G.; Reschke, M. F.; Wood, S. J.

    2015-01-01

    This joint ESA NASA study will address adaptive changes in spatial orientation related to the subjective straight ahead and the use of a vibrotactile sensory aid to reduce perceptual errors. The study will be conducted before and after long-duration expeditions to the International Space Station (ISS) to examine how spatial processing of target location is altered following exposure to microgravity. This study addresses the sensorimotor research gap to "determine the changes in sensorimotor function over the course of a mission and during recovery after landing."

  2. Straight Vegetable Oil as a Diesel Fuel?

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-01-01

    Biodiesel, a renewable fuel produced from animal fats or vegetable oils, is popular among many vehicle owners and fleet managers seeking to reduce emissions and support U.S. energy security. Questions sometimes arise about the viability of fueling vehicles with straight vegetable oil (SVO), or waste oils from cooking and other processes, without intermediate processing. But SVO and waste oils differ from biodiesel (and conventional diesel) in some important ways and are generally not considered acceptable vehicle fuels for large-scale or long-term use.

  3. The short straight sections for the LHC

    International Nuclear Information System (INIS)

    Bergot, J.B.; Coussy, E.; Dambre, P.; Ollivier, Y.; Reynet, D.; Vincent, D.; Rohmig, P.

    1999-01-01

    In 1995 a close collaboration between CERN, CEA and CNRS has been established for the design, proto-typing and follow-up of industrial series production of a sub-assembly of the Large Hadron Collider (LHC). In this frame, the design office of IPN's Accelerator R and D group has in charge one of these contracts concerning the 386 Short Straight Sections (SSS) and particularly: - the cryostat design; - the study of procedures and tool assembly; - the construction of two prototypes during the year 1999; - the industrialization and the production follow-up for the series SSS. This collaboration will last until the year 2004. (authors)

  4. Ranitidine has no influence on tubular creatinine secretion

    NARCIS (Netherlands)

    van den Berg, J. G.; Koopman, M. G.; Arisz, L.

    1996-01-01

    Oral cimetidine competitively inhibits tubular secretion of creatinine. We investigated the potential of oral ranitidine, a comparable H2-receptor antagonist, to block tubular creatinine secretion. In 10 healthy subjects, clearances of inulin and endogenous creatinine were simultaneously measured

  5. Drill pipes and casings utilizing multi-conduit tubulars

    Energy Technology Data Exchange (ETDEWEB)

    Curlett, H.B.

    1989-01-24

    A seal adapted for use with a multi-conduit well tubular, or the like, is described which consists of: a plate with fluid passages, each passage corresponding to an opening of a conduit of the multiconduit tubular, and a groove on the plate around each passage; and elastomer means partially embeddable into each groove for sealing each conduit of a tubular to a corresponding conduit of another similar tubular.

  6. Development of Partial Tubular Flat Knitting Fabric Composite Preform

    Directory of Open Access Journals (Sweden)

    Jiang Wei Qing

    2016-01-01

    Full Text Available After building some structures of partial tubular flat knitting fabric composite preform, the influencing factor on tubular section was analyzed and the fabric was knitted selectively. The partial tubular flat knitting fabric composite preform were Knitted by changing different yarn, row number and two-sided partial tubular flat knitting fabric. Multilayer sheet would be got after hot pressing and it has big market prospects and good application value.

  7. Tubular permanent magnet actuators: cogging forces characterization

    NARCIS (Netherlands)

    Paulides, J.J.H.; Janssen, J.L.G.; Encica, L.; Lomonova, E.A.

    2009-01-01

    Tubular permanent magnet actuators are evermore used in demanding industrial and automotive applications. However, these actuators can suffer from large cogging forces, which have a destabilizing effect on the servo control system and compromise position and speed control accuracy. This paper

  8. Work tool in a tubular element

    International Nuclear Information System (INIS)

    Griffaton, J.

    1991-01-01

    The stand, which is positioned in relation with the tubular element, has clutch disengagement means for a working rod in rotation, with at least two positioning regions on the rod. Application for laser welding a sleeve into PWR steam generator tubes [fr

  9. Boron--epoxy tubular structure members

    Science.gov (United States)

    Shakespeare, W. B. J.; Nelson, P. T.; Lindkvist, E. C.

    1973-01-01

    Composite materials fabricate thin-walled tubular members which have same load-carrying capabilities as aluminum, titanium, or other metals, but are lighter. Interface between stepped end fitting and tube lends itself to attachments by primary as well as secondary bonding. Interlaminar shear and hoop stress buildup in attachment at end fitting is avoided.

  10. Pointlike Inclusion Interactions in Tubular Membranes

    NARCIS (Netherlands)

    Vahid Belarghou, A.; Idema, T.

    2016-01-01

    Membrane tubes and tubular networks are ubiquitous in living cells. Inclusions like proteins are vital for both the stability and the dynamics of such networks. These inclusions interact via the curvature deformations they impose on the membrane. We analytically study the resulting membrane

  11. Reliability Analysis of Tubular Joints in Offshore Structures

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle; Sørensen, John Dalsgaard

    1987-01-01

    Reliability analysis of single tubular joints and offshore platforms with tubular joints is" presented. The failure modes considered are yielding, punching, buckling and fatigue failure. Element reliability as well as systems reliability approaches are used and illustrated by several examples....... Finally, optimal design of tubular.joints with reliability constraints is discussed and illustrated by an example....

  12. Diffraction patterns from 7-Angstroms tubular halloysite

    International Nuclear Information System (INIS)

    Eggleton, T.

    1998-01-01

    Full text: The diffraction patterns from 7-Angstroms tubular halloysite are superficially like those from kaolinite. Diffraction from a tubular aggregate of atoms, however, differs from that from a crystal because there is no linear repetition in two of the three conventional crystallographic directions. In tubular halloysite, the tube axis is [010] or [110] and in this direction the unit cell repeats in the normal linear fashion. The x-axis, by contrast, changes direction tangentially around the tube circumference, and there can be no true z-axis, because unit cells in the radial direction do not superimpose, since each successive tubular layer has a larger radius than its predecessor and therefore must contain more unit cells than its predecessor. Because tubular 'crystals' do not have a lattice repeat, use of Bragg 'hkl' indices is not appropriate. In the xy plane, a small area of the structure approximates a flat layer silicate, and hk indices may been used to label diffraction maxima. Similarly, successive 1:1 layers tangential to the tube walls yield a series of apparent 001 diffraction maxima. Measurement of these shows that the d-spacings do not form an exact integral series. The reason for this lies in the curvature of the structure. Calculated electron and powder X-ray diffraction patterns, based on a model of concentric 1:1 layers with no regular relation between them other than the 7.2 Angstroms spacing, closely simulate the observed data. Evidence for the 2-layer structure that is generally accepted may need to be reassessed in the light of these results

  13. VenUS I: a randomised controlled trial of two types of bandage for treating venous leg ulcers.

    Science.gov (United States)

    Iglesias, C; Nelson, E A; Cullum, N A; Torgerson, D J

    2004-07-01

    To compare the clinical and cost-effectiveness of two different compression bandages for the healing of venous leg ulcers. A pragmatic, randomised controlled trial with an economic evaluation. Community, district nurse-led services; community leg ulcer clinics; hospital leg ulcer clinics with community outreach. A range of urban and rural settings in England and Scotland. Patients with a venous leg ulcer of at least 1-week's duration, at least 1 cm in length or width and an ankle:brachial pressure index of at least 0.8. The four-layer bandage (4LB) (which is multilayer elastic compression) compared with the short-stretch bandage (SSB) (multilayer, inelastic compression). The primary end-point was complete healing of all the ulcers on the trial leg. Secondary outcomes were the proportion of patients healed at 12 and 24 weeks, rate of recurrence, costs of leg ulcer treatment and quality of life. Between April 1999 and December 2000 the trial recruited 387 people aged from 23 to 97 years at trial entry. The majority of patients in this trial (82%; 316/387) had a reference ulcer of area bandage groups, the distribution of the cumulative times to healing of individuals in the two trial groups was compared using the log-rank test. The difference in the distribution of cumulative healing times between the individuals in the two groups was not statistically significant at the 5% level. Adjusting for the effects of variables which may influence healing (centre, baseline ulcer area, duration, episodes, ankle mobility, weight) in a Cox proportional hazards model, a statistically significant treatment effect in favour of the 4LB was identified. At any point in time, the probability of healing for individuals in the SSB treatment arm is significantly lower than that for people treated with the 4LB. Our base case economic analysis showed that the 4LB is the dominant strategy, that is, it is associated with a greater health benefit and lower costs than the SSB, although the

  14. What is the existing evidence supporting the efficacy of compression bandage systems containing both elastic and inelastic components (mixed-component systems)? A systematic review.

    Science.gov (United States)

    Welsh, Lynn

    2017-05-01

    To analyse current evidence on the efficacy of bandage systems containing both elastic and inelastic components (mixed-component systems). International consensus on the efficacy of types of compression systems is difficult to achieve; however, mixed-component systems are being promoted as combining the best properties of both elastic and inelastic bandage systems and increasingly being used to treat venous leg ulcers in practice. A systematic literature review. Search terms such as venous leg ulcer, varicose ulcer, leg ulcer, compression, bandage, elastic, inelastic, short stretch, healing rate, interface pressure, mixed component, two-layer, four-layer and multi-layer were used in database and hand searches in several combinations. Limits were set for years 2005-March 2015 and English-language publications. A total of 475 studies were identified at initial search, and following elimination from abstract and title, this was reduced to 7. A further study was identified on Google Scholar, bringing the final number of studies fitting inclusion criteria to 8. The following subgroups relating to outcomes of efficacy were identified: ulcer healing, maintenance of interface pressure, slippage, ease of application and patient quality of life. Mixed-component systems were found to have comparable ulcer healing rates to alternative compression systems and be easy to apply; have similar abilities to maintain pressure as four-layer bandages and better abilities than short-stretch bandages; have less slippage than alternative systems; and to be significantly associated with several favourable quality of life outcomes. Clinician skill in bandage application was an uncontrolled variable in all eight papers included in the review, which may limit reliability of findings. This review synthesises existing evidence on the efficacy of mixed-component systems and encourages clinicians to regard them as an effective alternative to purely elastic or inelastic compression systems

  15. 78 FR 37584 - U.S. Steel Tubular Products, Inc., Mckeesport Tubular Operations Division, Subsidiary of United...

    Science.gov (United States)

    2013-06-21

    ... make the following certification: All workers of U.S. Steel Tubular Products, McKeesport Tubular... Products, Inc., Mckeesport Tubular Operations Division, Subsidiary of United States Steel Corporation, Mckeesport, Pennsylvania; Notice of Amended Certification Pursuant to Section 221 of the Trade Act of 1974...

  16. Attitudes toward straight, gay male, and transsexual parenting.

    Science.gov (United States)

    Weiner, Brittany A; Zinner, Leah

    2015-01-01

    This study examined American attitudes toward transsexual and gay male parenting, compared to straight parenting. After reporting levels of transphobia, participants read a vignette regarding a couple seeking child adoption. Individuals high in transphobia perceived nontraditional couples as more emotionally unstable than straight couples and were less willing to grant custody of a child to the nontraditional couples vs. the straight couples. In addition, the transsexual couple faced more prejudice and discrimination than the gay male couple. Implications of these findings are discussed.

  17. Free-boundary stability of straight stellarators

    International Nuclear Information System (INIS)

    Barnes, D.C.; Cary, J.R.

    1984-02-01

    The sharp-boundary model is used to investigate the stability of straight stellarators to free-boundary, long-wavelength modes. To correctly analyze the heliac configuration, previous theory is generalized to the case of arbitrary helical aspect ratio (ratio of plasma radius to periodicity lengths). A simple low-β criterion involving the vacuum field and the normalized axial current is derived and used to investigate a large variety of configurations. The predictions of this low-β theory are verified by numerical minimization of deltaW at arbitrary β. The heliac configuration is found to be remarkably stable, with a critical β of over 15% determined by the lack of equilibrium rather than the onset of instability. In addition, other previously studied systems are found to be stabilized by net axial plasma current

  18. A straightness error measurement method matched new generation GPS

    International Nuclear Information System (INIS)

    Zhang, X B; Lu, H; Jiang, X Q; Li, Z

    2005-01-01

    The axis of the non-diffracting beam produced by an axicon is very stable and can be adopted as the datum line to measure the spatial straightness error in continuous working distance, which may be short, medium or long. Though combining the non-diffracting beam datum-line with LVDT displace detector, a new straightness error measurement method is developed. Because the non-diffracting beam datum-line amends the straightness error gauged by LVDT, the straightness error is reliable and this method is matchs new generation GPS

  19. SOFC mini-tubulares basadas en YSZ

    Directory of Open Access Journals (Sweden)

    Campana, R.

    2008-08-01

    Full Text Available Tubular SOFC have the advantage over planar SOFC of the low temperature sealing and more resistance to thermal shock. On the other hand the volumetric power density of tubular Fuel Cells goes with the inverse of the tube diameter which added to the faster warm-up kinetics makes low diameter tubular SOFC favorable for low power applications. Anode supported tubular SOFC of 3mm diameter and 150 mm length with YSZ electrolyte were fabricated and tested by V-I measurements using H2-Ar (5, 10, 100 vol% as fuel and air for the cathode. The NiO-YSZ tubes of about 400 μm thickness were produced by hydrostatic pressure and then coated with an YSZ film of 15-20 μm. The electrolyte was deposited using a manual aerograph. After sintering either Pt paste or LSF (with YSZ or SDC coatings of about 20-50 μm thickness were deposited for the cathode. The OCV of the cells were excellent, very close to the expected Nernst law prediction indicating that there were not gas leaks. The maximun electrical power of the cell was near to 500mW/cm2 at 850ºC operation temperature. Complex impedance measurements of the cells were performed in order to determine the resistance of the different cell components.

    La principal ventaja de las SOFC tubulares frente a las planares es el sellado de la cámara anódica y catódica a bajas temperaturas. Además la densidad de energía volumétrica de las pilas tubulares es inversamente proporcional al diámetro del tubo, que añadido a los tiempos cortos de encendido y apagado hacen que las mini-tubulares sean interesantes para usos de baja potencia. Se han fabricado y caracterizado SOFC tubulares soportadas en ánodo de 3mm de diámetro y de 150 mm de longitud, 400μm de espesor, con electrolito de YSZ depositado por spray de 15-20 μm. Los tubos de NiO-YSZ son producidos por prensado isostático. La caracterización eléctrica se ha realizado empleando H2-Ar como combustible an

  20. Comparison of 4-Layer Bandages and an Adaptive Compression Therapy Device on Intended Pressure Delivery.

    Science.gov (United States)

    Mayrovitz, Harvey N; Partsch, Hugo; Vanscheidt, Wolfgang

    2015-01-01

    To characterize and compare interface pressure profiles of an adaptive compression therapy (ACT) device and a traditional 4-layer bandage (4LB) system. A prospective, randomized, open-label, 1-arm, active controlled study. The sample comprised 12 healthy volunteers. Subjects wore both devices for 8 hours on 3 consecutive days. Treatments were randomized to left and right legs. One clinician performed all applications and was experienced in the clinical use of both devices. Pressures were measured in seated and standing positions at the lower, mid, and upper calf immediately post application and after 1, 4, and 8 hours. Pressures achieved with the ACT were closer to targeted 40/30/20 mmHg graduated pressure values and were significantly less than the 4LB for corresponding sites/postures (P pressures (mean ± SD) for the ACT were 36.9 ± 4.9, 30.5 ± 4.5, and 21.0 ± 3.6 mmHg. Corresponding interface pressures for the 4LB were 52.5 ± 8.4, 57.5 ± 10.3, and 53.5 ± 12.9 mmHg. In the standing position, initial interface pressures for the ACT were 40.7 ± 4.8, 35.6 ± 4.5, and 21.1 ± 4.6 compared to 54.6 ± 12.5, 64.4 ± 10.9, and 53.7 ± 14.3 for the 4LB. At 1, 4, and 8 hours after application, the 4LB showed a significant progressive decline in interface pressure in both seated and standing positions (P pressures than the 4LB and the pressures achieved were consistent with contemporary venous ulcer therapy standards.

  1. Comparative evaluation of Comfilcon A and Senofilcon A bandage contact lenses after transepithelial photorefractive keratectomy.

    Science.gov (United States)

    Mukherjee, Achyut; Ioannides, Antonis; Aslanides, Ioannis

    2015-01-01

    To evaluate and compare Comfilcon A and Senofilcon A silicone hydrogel contact lenses used as a therapeutic bandage following transepithelial excimer laser photorefractive keratectomy (PRK). Patients undergoing transepithelial PRK for myopia were prospectively recruited. Included patients had a Comfilcon A silicone hydrogel lens inserted in one eye, with a Senofilcon A lens in the contralateral eye. Postoperative assessment of subjective pain, epithelial healing and visual recovery was at day 1, 3 and 7. Contact lens factors including centration, movement and deposits were assessed. 48 eyes of 24 patients were included in the study. Mean age was 31 years (SD 11) and mean refractive error -4.5 D (SD 1.8). Mean pain score at day 1 was significantly higher in the Comfilcon group at 4.6 (SD 2.7) vs. 1.5 (SD2.5) in the Senofilcon group (P<0.005). Mean time to healing was 3.17 days (SD 0.37) in the Comfilcon group, and 3.21 days (SD 0.4) in the Senofilcon group, with no difference in defect size. There was a pronounced central raphe in 1 eye in the Comfilcon group vs. 5 eyes in the Senofilcon group (P=0.19). Significantly more eyes demonstrated no lens movement in the Senofilcon group (18 vs. 4, P=0.0001). The variation in material characteristics and lens geometry of different silicone hydrogel lenses affects their clinical characteristics in therapeutic roles. Other factors than oxygen permeability may affect pain and epithelial healing, with superior pain relief from the less permeable Senofilcon lens in this study. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  2. In vitro results of flexible light-emitting antimicrobial bandage designed for prevention of surgical site infections

    Science.gov (United States)

    Greenberg, Mitchell; Sharan, Riti; Galbadage, Thushara; Sule, Preeti; Smith, Robert; Lovelady, April; Cirillo, Jeffrey D.; Glowczwski, Alan; Maitland, Kristen C.

    2018-02-01

    Surgical site infections (SSIs) are a leading cause of morbidity and mortality and a significant expense to the healthcare system and hospitals. The majority of these infections are preventable; however, increasing bacterial resistance, biofilm persistence, and human error contribute to the occurrence of these healthcare-associated infections. We present a flexible antimicrobial blue-light emitting bandage designed for use on postoperative incisions and wounds. The photonic device is designed to inactivate bacteria present on the skin and prevent bacterial colonization of the site, thus reducing the occurrence of SSIs. This antimicrobial light emitting bandage uses blue light's proven abilities to inactivate a wide range of clinical pathogens regardless of their resistance to antibiotics, inactivate bacteria without harming mammalian cells, improve wound healing, and inactivate bacteria in biofilms. The antimicrobial bandage consists of a thin 2"x2" silicone sheet with an array of 77 LEDs embedded in multiple layers of the material for thermal management. The 405 nm center wavelength LED array is designed to be a wearable device that integrates with standard hospital infection prevention protocols. The device was characterized for irradiance of 44.5 mW/cm2. Methicillin-resistant Staphylococcus aureus seeded in a petri dish was used to evaluate bacterial inactivation in vitro. Starting with a concentration of 2.16 x 107 colony forming units (CFU)/mL, 45% of the bacteria was inactivated within 15 minutes, 65% had been inactivated by 30 minutes, 99% was inactivated by 60 minutes, and a 7 log reduction and complete sterilization was achieved within 120 minutes.

  3. The Canadian Bandaging Trial: Evidence-informed leg ulcer care and the effectiveness of two compression technologies

    OpenAIRE

    Harrison, Margaret B; VanDenKerkhof, Elizabeth G; Hopman, Wilma M; Graham, Ian D; Carley, Meg E; Nelson, E Andrea

    2011-01-01

    Abstract Background Objective: To determine the relative effectiveness of evidence-informed practice using two high compression systems: four-layer (4LB) and short-stretch bandaging (SSB) in community care of venous leg ulcers. Design and Setting: Pragmatic, multi-centre, parallel-group, open-label, randomized controlled trial conducted in 10 centres. Cognitively intact adults (≥18 years) referred for community care (home or clinic) with a venous ulceration measuring ≥0.7cm and present for ≥1...

  4. Effect of a stent bandage on the likelihood of incisional infection following exploratory coeliotomy for colic in horses

    DEFF Research Database (Denmark)

    Tnibar, Aziz; Grubbe Lin, Kathrine; Nielsen, Katrine Thurøe

    2013-01-01

    criteria were animals that had one ventral midline coeliotomy and had survived at least 10 days after surgery. Horses were categorised into 2 groups:no-stent group and stent group. The following data were collected for each case: age, sex, weight, heart rate, packed cell volume, primary lesion, performance...... of an enterotomy or intestinal resection, surgical classification, use of local antimicrobials, duration of surgery, intra-abdominal administration of sodium carboxymethylcellulose, intravenous administration of lidocaine, surgeon, use of a stent bandage, duration of stent use, and use of a belly band. Factors...

  5. Chirality of Single-Handed Twisted Titania Tubular Nanoribbons Prepared Through Sol-gel Transcription.

    Science.gov (United States)

    Wang, Sibing; Zhang, Chuanyong; Li, Yi; Li, Baozong; Yang, Yonggang

    2015-08-01

    Single-handed twisted titania tubular nanoribbons were prepared through sol-gel transcription using a pair of enantiomers. Handedness was controlled by that of the template. The obtained samples were characterized using field-emission electron microscopy, transmission electron microscopy, diffuse reflectance circular dichroism (DRCD), and X-ray diffraction. The DRCD spectra indicated that the titania nanotubes exhibit optical activity. Although the tubular structure was destroyed after being calcined at 700 °C for 2.0 h, DRCD signals were still identified. However, the DRCD signals disappeared after being calcined at 1000 °C for 2.0 h. The optical activity of titania was proposed to be due to chiral defects. Previous results showed that straight titania tubes could be used as asymmetric autocatalysts, indicating that titania exhibit chirality at the angstrom level. Herein, it was found that they also exhibit DRCD signals, indicating that there are no obvious relationships between morphology at the nano level and chirality at the angstrom level. The nanotube chirality should originate from the chiral defects on the nanotube inner surface. The Fourier transform infrared spectra indicated that the chirality of the titania was transferred from the gelators through the hydrogen bonding between N-H and Ti-OH. © 2015 Wiley Periodicals, Inc.

  6. A simple method for estimating the length density of convoluted tubular systems.

    Science.gov (United States)

    Ferraz de Carvalho, Cláudio A; de Campos Boldrini, Silvia; Nishimaru, Flávio; Liberti, Edson A

    2008-10-01

    We present a new method for estimating the length density (Lv) of convoluted tubular structures exhibiting an isotropic distribution. Although the traditional equation Lv=2Q/A is used, the parameter Q is obtained by considering the collective perimeters of tubular sections. This measurement is converted to a standard model of the structure, assuming that all cross-sections are approximately circular and have an average perimeter similar to that of actual circular cross-sections observed in the same material. The accuracy of this method was tested in eight experiments using hollow macaroni bent into helical shapes. After measuring the length of the macaroni segments, they were boiled and randomly packed into cylindrical volumes along with an aqueous suspension of gelatin and India ink. The solidified blocks were cut into slices 1.0 cm thick and 33.2 cm2 in area (A). The total perimeter of the macaroni cross-sections so revealed was stereologically estimated using a test system of straight parallel lines. Given Lv and the reference volume, the total length of macaroni in each section could be estimated. Additional corrections were made for the changes induced by boiling, and the off-axis position of the thread used to measure length. No statistical difference was observed between the corrected estimated values and the actual lengths. This technique is useful for estimating the length of capillaries, renal tubules, and seminiferous tubules.

  7. Stigma and Stigma by Association in Perceptions of Straight Allies

    Science.gov (United States)

    Goldstein, Susan B.

    2017-01-01

    As evidence builds for straight allies' contributions to battling sexual prejudice, barriers to assuming this role must be identified and dismantled. This study investigated stigma and stigma by association in perceptions of straight allies in a college population. Adjective rating items were completed by 505 participants who identified as…

  8. Setting the Record Straight. The Truth About Fad Diets.

    Science.gov (United States)

    Wheat Foods Council, Parker, CO.

    The Setting the Record Straight information packet presents facts to set the record straight about nutrition and debunk fad diets. The kit features materials designed to communicate the importance of balanced eating. Materials include: a time line of fad diets; four reproducible fad diet book review handouts that show the misleading claims rampant…

  9. Spider diffraction: a comparison of curved and straight legs

    International Nuclear Information System (INIS)

    Richter, J.L.

    1984-01-01

    It has been known for some time that, if curved legs rather than the usual straight ones are used in the spider that supports the secondary optics in certain telescopes, the visible diffraction effect is reduced. Fraunhofer theory is used to calculate the diffraction effects due to the curved leg spider. Calculated and photographic diffraction patterns are compared for straight and curved leg spiders

  10. Scintillation investigation of the straight back syndrome

    International Nuclear Information System (INIS)

    Ebaid, M.; Serro Azul, L.G.; Kedor, H-H.; Papaleo Netto, M.; Mignone, C.A.; Carvalho, N. de

    1976-01-01

    Scintigraphic study of the lungs was undertaken in 17 patients with the straight back syndrome divided in three groups: I. mild form; II. moderate form and III. severe form. The results showed that: a) there is a decreased flow through the pulmonary arteries; b) bilateral morphological alterations are most common (64.6%); c) the compression of the chest cause an increased cardiac silhouette in groups II (22.2%) and III (50%) besides widening of the mediastinum in all groups (25%, 44.4% and 75%, respectively); d. functional restriction is moderate in 61.5% and severe in 38.4% of the patients in the first two groups; in group III, moderate restriction is observed in 75% of the patients and severe restriction in 25%. Results indicate that the alterations observed in the scintigraphic study of the strainght back syndrome are caused by the effects of the deformed chest on the arterial perfusion of the lung. However, the severity of the anomaly and the decrease in the pulmonary circulation could not be correlated statistically [pt

  11. Distal renal tubular acidosis and hepatic lipidosis in a cat.

    Science.gov (United States)

    Brown, S A; Spyridakis, L K; Crowell, W A

    1986-11-15

    Clinical and laboratory evidence of hepatic failure was found in a chronically anorectic cat. Simultaneous blood and urine pH determinations established a diagnosis of distal renal tubular acidosis. The cat did not respond to treatment. Necropsy revealed distal tubular nephrosis and hepatic lipidosis. The finding of distal renal tubular acidosis in a cat with hepatic lipidosis emphasizes the importance of complete evaluation of acid-base disorders in patients.

  12. Clinical study of two kinds of bandage contact lenses after laser-assisted subepithelial keratectomy

    Directory of Open Access Journals (Sweden)

    Wan-Ting Zhang

    2016-07-01

    Full Text Available AIM: To investigate the clinical safety and effectiveness of the two kind of bandage contact lenses: Senofilcon A(Johnson & Johnson Acuvue Oasysand Balafilcon A(Bausch& Lomb pure visionafter laser-assisted subepithelial keratectomy(LASEK. METHODS: Thirty-eight patients(76 eyeswho had undergone the LASEK were divided into two groups. One group of patients wore Balafilcon A, the other group of patients fitted with Senofilcon A. The lenses were worn continuously for 7d. This was a seven-day experience and the patients scored for the symptom of the eyes(sore eyes, foreign body sensation and tearingon the third day and the seventh day. Both of the two groups of patients taken off the soft contact lens on the seventh day and let their vision and corneal staining checked.RESULTS: The symptoms of eye sore and tearing of the two groups patients were different. The patients who wore the Senofilcon A were better. The pain of eyes were also different at 3 and 7d after surgeries(Z=-4.146, P=0.000; Z=-2.814, P=0.005. The difference on tearing between the two groups at 3 and 7d after surgeries were significant(Z=-2.309, P=0.021; Z=-3.276, P=0.001. There was no difference on sensation of dryness between the two groups at 3 and 7d after surgeries(Z=-0.447, P=0.655; Z=-0.966, P=0.334. After the lenses were taken off, the visual acuity of patients wearing Senofilcon A was better(t=3.800, P=0.001; corneal staining showed limited spots in 1-2 quadrants with significant difference(Z=-2.384,P=0.017. CONCLUSION: The Senofilcon A(Johnson & Johnson Acuvue Oasysand Balafilcon A(Bausch& Lomb pure visionbandage contact lenses are safe and effective after LASEK, and the former is better than the latter in epithelial regeneration.

  13. Cardiac implantable electronic device hematomas: Risk factors and effect of prophylactic pressure bandaging.

    Science.gov (United States)

    Koh, Youlin; Bingham, Nicholas E; Law, Natalie; Le, Dustin; Mariani, Justin A

    2017-07-01

    Cardiac implantable electronic device (CIED) hematomas are associated with many adverse outcomes. We examined the incidence and risk factors associated with hematoma formation post-CIED implantation, and explored the preventative effect of prophylactic pressure bandaging (PPB) in a large tertiary center. 1,091 devices were implanted during October 2011-December 2014. Clinically significant hematomas (CSH) were those that necessitated prolonged admission, including those due to reoperation, and clinically suspicious hematomas were swellings noted by medical/nursing staff. We screened for variables affecting hematoma incidence prior to conducting multivariate logistic regression analyses, one for all hematomas and one for CSH. 61 hematomas were identified (5.6% of patients), with 12 of those clinically significant (1.1% of patients). Factors significantly increasing the odds of developing any hematoma were stage 2 (odds ratio [OR] = 2.93, 95% confidence interval [CI] [1.08-7.94], P = 0.034) and 3 chronic kidney disease (CKD) (OR = 3.39 [1.20-9.56], P = 0.021), unfractionated heparin/therapeutic enoxaparin (OR = 3.15 [1.22-8.14], P = 0.018), and dual antiplatelets-aspirin + clopidogrel (OR = 2.95 [1.14-7.65], P = 0.026) + other combinations. Body Mass index (BMI) 25.0-29.9 (OR 0.52 [0.28-0.98], P = 0.044) and >30 were associated with decreased hematoma risk (OR 0.43 [0.20-0.91], P = 0.028). Factors significant for CSH formation were unfractionated heparin/therapeutic enoxaparin (OR = 9.55 [1.83-49.84], P = 0.007) and aspirin + clopidogrel (OR = 7.19 [1.01-50.91], P = 0.048). PPB nonsignificantly increased the odds of total hematoma development (OR = 1.53 [0.87-2.69], P = 0.135), and reduced CSH (OR = 0.67 [0.18-2.47], P = 0.547). Heparin and dual antiplatelet use remain strong predictors of overall hematoma formation. CKD is a comparatively moderate predictor. BMI > 25 may decrease the risk of hematoma formation. PPB had nonsignificant effects on hematoma development

  14. TUBULAR DISORDERS WITH RICKETS-LIKE SYNDROME

    Directory of Open Access Journals (Sweden)

    N.N. Kartamysheva

    2011-01-01

    Full Text Available Often under the guise of «ordinary» Rickets are more severe kidney diseases, developing as a result of inherited or acquired, primary or secondary defects in the renal tubules. Incorrect diagnosis leads to an inadequate therapy, rapid progression of disease and renal failure. The article describes the main approaches to the diagnosis and treatment of disorders of tubular rachitis similar syndrome, presents a number of clinical cases in author's practice.Key words: tubulopathy, acidosis, electrolyte disorders, rickets, rickets-like syndrome, diagnostics, treatment, children.

  15. Fractal solutions of recirculation tubular chemical reactors

    International Nuclear Information System (INIS)

    Berezowski, Marek

    2003-01-01

    Three kinds of fractal solutions of model of recirculation non-adiabatic tubular chemical reactors are presented. The first kind concerns the structure of Feigenbaum's diagram on the limit of chaos. The second kind and the third one concern the effect of initial conditions on the dynamic solutions of models. In the course of computations two types of recirculation were considered, viz. the recirculation of mass (return of a part of products' stream) and recirculation of heat (heat exchange in the external heat exchanger)

  16. Tubular solid oxide fuel cell development program

    Energy Technology Data Exchange (ETDEWEB)

    Ray, E.R.; Cracraft, C.

    1995-12-31

    This paper presents an overview of the Westinghouse Solid Oxide Fuel Cell (SOFC) development activities and current program status. The Westinghouse goal is to develop a cost effective cell that can operate for 50,000 to 100,000 hours. Progress toward this goal will be discussed and test results presented for multiple single cell tests which have now successfully exceeded 56,000 hours of continuous power operation at temperature. Results of development efforts to reduce cost and increase power output of tubular SOFCs are described.

  17. Paired Straight Hearth Furnace - Transformational Ironmaking Process

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Wei-Kao [McMaster Univ., Hamilton, ON (Canada); Debski, Paul [Andritz Metals Inc.,Canonsburg, PA (United States)

    2014-11-19

    The U. S. steel industry has reduced its energy intensity per ton of steel shipped by 33% since 1990. However, further significant gains in energy efficiency will require the development of new, transformational iron and steelmaking processes. The Paired Straight Hearth Furnace (PSH) process is an emerging alternative high productivity, direct reduced iron (DRI) technology that may achieve very low fuel rates and has the potential to replace blast furnace ironmaking. The PSH furnace can operate independently or may be coupled with other melting technologies to produce liquid hot metal that is both similar to blast furnace iron and suitable as a feedstock for basic oxygen steelmaking furnaces. The PSH process uses non-metallurgical coal as a reductant to convert iron oxides such as iron ore and steelmaking by-product oxides to DRI pellets. In this process, a multi-layer, nominally 120mm tall bed of composite “green balls” made from oxide, coal and binder is built up and contained within a moving refractory hearth. The pellet bed absorbs radiant heat energy during exposure to the high temperature interior refractory surfaces of the PSH while generating a strongly reducing gas atmosphere in the bed that yields a highly metalized DRI product. The PSH concept has been well tested in static hearth experiments. A moving bed design is being developed. The process developers believe that if successful, the PSH process has the potential to replace blast furnaces and coke ovens at a fraction of the operating and capital cost while using about 30% less energy relative to current blast furnace technology. DRI output could also feed electric arc furnaces (EAFs) by displacing a portion of the scrap charge.

  18. Conceptual Design of ILC Damping Ring Wiggler Straight Vacuum System

    International Nuclear Information System (INIS)

    Marks, S.; Kennedy, K.; Plate, D.; Schlueter, R.D.; Zisman, M.

    2007-01-01

    The positron and electron damping rings for the International Linear Collider will contain long straight sections consisting of twenty wiggler/quadrupole pairs. The wigglers will be based upon the CESR superconducting design. There are a number of challenges associated with the design of the wiggler straight vacuum system, in particular, the absorption of photon power generated by the wigglers. This paper will present the overall conceptual design of the wiggler straight vacuum system developed for the ILC Reference Design Report. Particular emphasis will be placed on photon power load calculations and the absorber design

  19. Tubular fluoropolymer arrays with high piezoelectric response

    Science.gov (United States)

    Zhukov, Sergey; Eder-Goy, Dagmar; Biethan, Corinna; Fedosov, Sergey; Xu, Bai-Xiang; von Seggern, Heinz

    2018-01-01

    Polymers with electrically charged internal air cavities called ferroelectrets exhibit a pronounced piezoelectric effect and are regarded as soft functional materials suitable for sensor and actuator applications. In this work, a simple method for fabricating piezoelectret arrays with open-tubular channels is introduced. A set of individual fluoroethylenepropylene (FEP) tubes is compressed between two heated metal plates. The squeezed FEP tubes are melted together at +270 °C. The resulting structure is a uniform, multi-tubular, flat array that reveals a strong piezoelectric response after a poling step. The fabricated arrays have a high ratio between piezoelectrically active and non-active areas. The optimal charging voltage and stability of the piezoelectric coefficients with pressures and frequency were experimentally investigated for two specific array structures with wall thickness of 50 and 120 μm. The array fabricated from 50 μm thick FEP tubes reveals a stable and high piezoelectric coefficient of {d}33 = 120-160 pC N-1 with a flat frequency response between 0.1 Hz and 10 kHz for pressures between 1 and 100 kPa. An increase of wall thickness to 120 μm is accompanied by a more than twofold decrease in the piezoelectric coefficient as a result of a simultaneously higher effective array stiffness and lower remanent polarization. The obtained experimental results can be used to optimize the array design with regard to the electromechanical performance.

  20. Straight Talk for Good Health | NIH MedlinePlus the Magazine

    Science.gov (United States)

    ... of this page please turn Javascript on. Feature: Straight Talk for Good Health Straight Talk for Good Health Past Issues / Spring 2013 ... with your Doctor nihseniorhealth.gov/talkingwithyourdoctor/toc.html Straight talk with your healthcare provider is important. You ...

  1. Equilibrium depth of scour at straight guide banks

    Science.gov (United States)

    Gjunsburgs, B.; Bulankina, V.

    2017-10-01

    The equilibrium stage of scour at the head of straight guide banks with a uniform and stratified bed conditions have been studied. The contraction of the river by bridge crossing with straight guide banks considerably alters the flow pattern. The streamlines become curve and the concentration of streamlines, longitudinal and transverse slopes of the water surface, a local increase in velocity, vortex and eddy structures, and the origin of a flow separation zone between the extreme streamlines and the guide bank are observed and local scour is developing at the head of the straight guide banks. New formulae for calculation of equilibrium depth of scour at straight guide banks at uniform and stratified river bed is elaborated and confirmed by tests and computer modelling results.

  2. Highly sensitive straightness measurement system using a ball-lens

    International Nuclear Information System (INIS)

    Lee, Minho; Yang, Hyun-Ik; Cho, Nahm-Gyoo

    2016-01-01

    In this paper, a new and simple optical technique to accurately measure the straightness errors of a linear stage is proposed. To improve the performance, including the measurement sensitivity and resolution of the measurement system, and to simultaneously measure two-dimensional straightness errors (2D straightness errors), an optical system was designed using a laser, a retro-reflector, a ball-lens, and a two-dimensional position sensitive detector (2D PSD). The characteristics of the measurement system were analytically and experimentally investigated. A prototype measurement system was manufactured based on the investigated results, and the performances of this system have been tested. The measuring performance of the system was easily improved by about 12 times using the proposed technique and it can be further improved. It is shown that the proposed technique can easily and effectively improve the performance of a conventional straightness measurement system based on the geometric optical method using a PSD. (paper)

  3. Straight studs from southern pine veneer cores and cordwood

    Science.gov (United States)

    Peter Koch

    1968-01-01

    An economically feasible system has been developed for converting southern pine veneer cores into straight 8-foot studs (2). Prototype studs - two per core - were 100 percent SPIB stud grade and better.

  4. Uncertainty of spatial straightness in 3D measurement

    International Nuclear Information System (INIS)

    Wang Jinxing; Jiang Xiangqian; Ma Limin; Xu Zhengao; Li Zhu

    2005-01-01

    The least-square method is commonly employed to verify the spatial straightness in actual three-dimensional measurement process, but the uncertainty of the verification result is usually not given by the coordinate measuring machines. According to the basic principle of spatial straightness least-square verification and the uncertainty propagation formula given by ISO/TS 14253-2, a calculation method for the uncertainty of spatial straightness least-square verification is proposed in this paper. By this method, the coefficients of the line equation are regarded as a statistical vector, so that the line equation, the result of the spatial straightness verification and the uncertainty of the result can be obtained after the expected value and covariance matrix of the vector are determined. The method not only assures the integrity of the verification result, but also accords with the requirement of the new generation of GPS standards, which can improve the veracity of verification

  5. Rectosigmoid tubular duplication presenting as perineal sepsis in a neonate.

    Science.gov (United States)

    Zhang, Zhibo; Huang, Ying; Wang, Dajia; Su, Pengjun

    2010-03-01

    Tubular rectal duplication is a very rare congenital anomaly. We report a case of tubular rectal duplication in a newborn baby who presented with perianal sepsis. The diagnosis was confirmed by barium enema, magnetic resonance imaging, and at operation. We performed total mucosectomy through a posterior sagittal incision combined with laparotomy. The patient was doing quite well at 17-month follow-up examination.

  6. Cyclosporine A induces senescence in renal tubular epithelial cells

    NARCIS (Netherlands)

    Jennings, Paul; Koppelstaetter, Christian; Aydin, Sonia; Abberger, Thomas; Wolf, Anna Maria; Mayer, Gert; Pfaller, Walter

    The nephrotoxic potential of the widely used immunosuppressive agent cyclosporine A (CsA) is well recognized. However, the mechanism of renal tubular toxicity is not yet fully elucidated. Chronic CsA nephropathy and renal organ aging share some clinical features, such as renal fibrosis and tubular

  7. Intrarenal purinergic signaling in the control of renal tubular transport

    DEFF Research Database (Denmark)

    Prætorius, Helle; Leipziger, Jens Georg

    2010-01-01

    -reaching advances indicate that ATP is often used as a local transmitter for classical sensory transduction. This transmission apparently also applies to sensory functions in the kidney. Locally released ATP is involved in sensing of renal tubular flow or in detecting the distal tubular load of NaCl at the macula...

  8. Qingping Straight Sword: The Last Remaining Chinese Sword System?

    Directory of Open Access Journals (Sweden)

    Stephan Berwick

    2012-07-01

    Full Text Available The following examination of classical Chinese straight sword (jian details the very rare Qingping straight sword system. The study meshes Chinese- and English-sourced research with a revealing interview (conducted by America’s senior Qingping disciples, Reza Momenan and Hon Lee with Lu Junhai—the grandmaster of this unique sword system. The author presents Qingping system as perhaps the only known, complete Chinese sword system surviving from China’s pre-Rebulican era (1911-1949.

  9. Exact equivalent straight waveguide model for bent and twisted waveguides

    DEFF Research Database (Denmark)

    Shyroki, Dzmitry

    2008-01-01

    Exact equivalent straight waveguide representation is given for a waveguide of arbitrary curvature and torsion. No assumptions regarding refractive index contrast, isotropy of materials, or particular morphology in the waveguide cross section are made. This enables rigorous full-vector modeling...... of in-plane curved or helically wound waveguides with use of available simulators for straight waveguides without the restrictions of the known approximate equivalent-index formulas....

  10. Influence of Elastic Bandage and Neoprene Ankle Support on Ankle Position Sense and Pain in Subjects with Ankle Sprain (Grade I & II

    Directory of Open Access Journals (Sweden)

    Basir Majdoleslami

    2004-06-01

    Full Text Available Objective: to investigate whether a neoprene ankle support and elastic bandage around the ankle joint of subjects with ankle sprain (grade I&II would , in short term (a reduce pain (b improve ankle joint position sense and comparison of their effect with each other if they have. Materials & Methods: In a semi-experimental study, 30 subjects (16men, 14 women, age between 16-52 with ankle sprain grade I&II. Subjects had to have at least 2cm from 10cm visual analogue scale (VAS of ankle pain for study entry. All patients were randomly assigned to either an elastic bandage or a neoprene ankle support. One week later they were assigned to the opposite selection. Joint position sense was assessed in the sitting position using an electrogoniometer and pain by VAS where 0cm equals no pain and 10 cm equals worst pain. ankle pain and JPS were assessed for each selection one week apart. During each visit assessment were performed at baseline and after 20 min of bandage/neoprene ankle support application. Results: the mean of scores for ankle variables JPS and VAS was taken and paired-t test and Wilcoxon signed rank test was employed to calculate the different between two trails. Neoprene ankle support had significant effect on ankle JPS (P=0.034. But elastic bandage had no effect (P=0.539. Both of them had significantly reduced ankle pain. (P=0.000  Conclusion: In subjects with both neoprene ankle support and elastic bandage reduced ankle pain with more effect of neoprene ankle support. Only the neoprene ankle support had effect on knee JPS.

  11. Straight leg elevation to rule out pelvic injury.

    Science.gov (United States)

    Bolt, Caroline; O'Keeffe, Francis; Finnegan, Pete; Dickson, Kristofer; Smit, De Villiers; Fitzgerald, Mark C; Mitra, Biswadev

    2018-02-01

    Pelvic x-ray is frequently used as a screening tool during initial assessment of injured patients. However routine use in the awake and alert blunt trauma patient may be questioned due to low yield. We propose a clinical tool that may avoid unnecessary imaging by examining whether the ability to straight leg raise, without pain, can rule out pelvic injury. We conducted a prospective cohort study with the exposure variables of ability to straight leg raise and presence of pain on doing so, and presence of pelvic fracture on x-ray as the primary outcome variable. Of the 328 participants, 35 had pelvic fractures, and of these 32 were either unable to straight leg raise, or had pain on doing so, with a sensitivity of 91.43% (95% CI: 76.94-98.2%) and a negative predictive value of 98.57% (95% CI: 95.88-99.70%). The 3 participants with a pelvic fracture who could straight leg raise with no pain, all had a GCS of less than 15, and therefore, among the sub-group of patients with GCS15, a 100% sensitivity and 100% negative predictive value for straight leg raise with no pain to rule out pelvic fracture was demonstrated. Among awake, alert patients, painless straight leg raise can exclude pelvic fractures and be incorporated into initial examination during reception and resuscitation of injured patients. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  12. Forming of Polymeric Tubular Micro-components

    DEFF Research Database (Denmark)

    Qin, Yi; Zhao, Jie; Anyasodor, Gerald

    2015-01-01

    platform for the production of functional polymeric tubular micro-components. The chapter gives background on the current market and process development trends, followed by description of materials, process configuration, tool design and machine development for each processing technology as well......This chapter is intended to provide an overview of three nontraditional shaping technologies for the forming of polymeric micro-tubes, which are hot embossing, blow molding, and cross rolling, as well as realization of a process chain and the integration of a modular machine-based manufacturing...... as strategy for integration of the technologies and equipment into a common platform. Finally, potential applications of the technologies and facilities developed are highlighted....

  13. Sunscope natural light systems : tubular skylights

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    This brochure described a tubular skylight designed by Sunscope Natural Light Systems. The Sunscope is a super-reflective light system in which daylight is reflected down a cylinder to a translucent ceiling fixture that diffuses natural light throughout the room in which it is placed. The Sunscope requires no structure changes, is installed in less than 3 hours, and requires no drywall repairs or repainting. The system eliminates the need for daytime electric lighting, and causes no winter heat losses or summer heat gains. Available in 3 sizes, the Sunscope has no moving parts and is fully maintenance-free. The system was designed for use in commercial and residential applications. 7 figs.

  14. Inherited renal tubular defects with hypokalemia

    Directory of Open Access Journals (Sweden)

    Muthukrishnan J

    2009-01-01

    Full Text Available Bartter′s and Gitelman′s syndrome are two ends of a spectrum of inherited renal tubular disorders that present with hypokalemic metabolic alkalosis of varying severity. Clinical features and associated calcium and magnesium ion abnormalities are used to diagnose these cases after excluding other commoner causes. We report on two cases, the first being a young boy, born of pregnancy complicated by polyhydramnios, who had classical dysmorphic features, polyuria, hypokalemia and hypercalciuria and was diagnosed as having Bartter′s syndrome. The second patient is a lady who had recurrent tetany as the only manifestation of Gitelman′s syndrome, which is an unusual presentation. Potassium replacement with supplementation of other deficient ions led to satisfactory clinical and biochemical response.

  15. An ultrasonic inspection tool for production tubulars

    Energy Technology Data Exchange (ETDEWEB)

    Newton, K; Martin, R; Ravenscroft, F [AEA Technology, Harwell (United Kingdom)

    1994-06-01

    Advances in ultrasonic technology, high temperature techniques and remote processing power are enabling a new generation of inspection tools to be developed. This paper describes a particular new ultrasonic caliper system, developed by AEA Technology, with the aim of providing improved information about the condition of production tubulars of oil and gas wells. The system is designed to provide enhanced surface area coverage compared to the current devices, which are typically mechanical 'finger' calipers. It also provides a non-contacting measure of corrosion and wear together with direct on-line output and automated data analysis. The new tool is designed to operate in oil and gas, vertical or deviated wells and has the potential for modification to inspect small diameter pipes in topside or other plant. (author)

  16. The Canadian Bandaging Trial: Evidence-informed leg ulcer care and the effectiveness of two compression technologies

    Directory of Open Access Journals (Sweden)

    Hopman Wilma M

    2011-10-01

    Full Text Available Abstract Background Objective: To determine the relative effectiveness of evidence-informed practice using two high compression systems: four-layer (4LB and short-stretch bandaging (SSB in community care of venous leg ulcers. Design and Setting: Pragmatic, multi-centre, parallel-group, open-label, randomized controlled trial conducted in 10 centres. Cognitively intact adults (≥18 years referred for community care (home or clinic with a venous ulceration measuring ≥0.7cm and present for ≥1 week, with an ankle brachial pressure index (ABPI ≥0.8, without medication-controlled Diabetes Mellitus or a previous failure to improve with either system, were eligible to participate. Methods Consenting individuals were randomly allocated (computer-generated blocked randomization schedule to receive either 4LB or SSB following an evidence-informed protocol. Primary endpoint: time-to- healing of the reference ulcer. Secondary outcomes: recurrence rates, health-related quality of life (HRQL, pain, and expenditures. Results 424 individuals were randomized (4LB n = 215; SSB n = 209 and followed until their reference ulcer was healed (or maximum 30 months. An intent-to-treat analysis was conducted on all participants. Median time to ulcer healing in the 4LB group was 62 days [95% confidence interval (CI 51 to 73], compared with 77 days (95% CI 63 to 91 in the SSB group. The unadjusted Kaplan-Meier curves revealed the difference in the distribution of cumulative healing times was not significantly different between group (log rank χ2 = 0.001, P = 0.98 nor ulcers recurrence (4LB, 10.1%; SSB, 13.3%; p = 0.345. Multivariable Cox Proportional Hazard Modeling also showed no significant between-bandage differences in healing time after controlling for significant covariates (p = 0.77. At 3-months post-baseline there were no differences in pain (no pain: 4LB, 22.7%; SSB, 26.7%; p = 0.335, or HRQL (SF-12 Mental Component Score: 4LB, 55.1; SSB, 55.8; p = 0.615; SF

  17. The Canadian Bandaging Trial: Evidence-informed leg ulcer care and the effectiveness of two compression technologies

    Science.gov (United States)

    2011-01-01

    Background Objective: To determine the relative effectiveness of evidence-informed practice using two high compression systems: four-layer (4LB) and short-stretch bandaging (SSB) in community care of venous leg ulcers. Design and Setting: Pragmatic, multi-centre, parallel-group, open-label, randomized controlled trial conducted in 10 centres. Cognitively intact adults (≥18 years) referred for community care (home or clinic) with a venous ulceration measuring ≥0.7cm and present for ≥1 week, with an ankle brachial pressure index (ABPI) ≥0.8, without medication-controlled Diabetes Mellitus or a previous failure to improve with either system, were eligible to participate. Methods Consenting individuals were randomly allocated (computer-generated blocked randomization schedule) to receive either 4LB or SSB following an evidence-informed protocol. Primary endpoint: time-to- healing of the reference ulcer. Secondary outcomes: recurrence rates, health-related quality of life (HRQL), pain, and expenditures. Results 424 individuals were randomized (4LB n = 215; SSB n = 209) and followed until their reference ulcer was healed (or maximum 30 months). An intent-to-treat analysis was conducted on all participants. Median time to ulcer healing in the 4LB group was 62 days [95% confidence interval (CI) 51 to 73], compared with 77 days (95% CI 63 to 91) in the SSB group. The unadjusted Kaplan-Meier curves revealed the difference in the distribution of cumulative healing times was not significantly different between group (log rank χ2 = 0.001, P = 0.98) nor ulcers recurrence (4LB, 10.1%; SSB, 13.3%; p = 0.345). Multivariable Cox Proportional Hazard Modeling also showed no significant between-bandage differences in healing time after controlling for significant covariates (p = 0.77). At 3-months post-baseline there were no differences in pain (no pain: 4LB, 22.7%; SSB, 26.7%; p = 0.335), or HRQL (SF-12 Mental Component Score: 4LB, 55.1; SSB, 55.8; p = 0.615; SF-12 Physical

  18. Cytocompatibility of a silk fibroin tubular scaffold

    International Nuclear Information System (INIS)

    Wang, Jiannan; Wei, Yali; Yi, Honggen; Liu, Zhiwu; Sun, Dan; Zhao, Huanrong

    2014-01-01

    Regenerated silk fibroin (SF) materials are increasingly used for tissue engineering applications. In order to explore the feasibility of a novel biomimetic silk fibroin tubular scaffold (SFTS) crosslinked by poly(ethylene glycol) diglycidyl ether (PEG-DE), biocompatibility with cells was evaluated. The novel biomimetic design of the SFTS consisted of three distinct layers: a regenerated SF intima, a silk braided media and a regenerated SF adventitia. The SFTS exhibited even silk fibroin penetration throughout the braid, forming a porous layered tube with superior mechanical, permeable and cell adhesion properties that are beneficial to vascular regeneration. Cytotoxicity and cell compatibility were tested on L929 cells and human umbilical vein endothelial cells (EA.hy926). DNA content analysis, scanning electron and confocal microscopies and MTT assay showed no inhibitory effects on DNA replication. Cell morphology, viability and proliferation were good for L929 cells, and satisfactory for EA.hy926 cells. Furthermore, the suture retention strength of the SFTS was about 23 N and the Young's modulus was 0.2–0.3 MPa. Collectively, these data demonstrate that PEG-DE crosslinked SFTS possesses the appropriate cytocompatibility and mechanical properties for use as vascular scaffolds as an alternative to vascular autografts. - Highlights: • A PEG-DE cross-linked small caliber porous silk fibroin tubular scaffold (SFTS) • PEG-DE cross-linked SF film had no inhibitory effect on DNA replication of cells. • Cells cultured on the SFTS showed good morphology, cell viability and proliferative activity. • SFTS would be beneficial to endothelialization. • SFTS had good suture retention strength and flexibility

  19. Straight-Line: A nuclear material storage information management system

    International Nuclear Information System (INIS)

    Nilsen, C.; Mangan, D.

    1995-01-01

    Sandia National Laboratories is developing Straight-Line -- a pilot system to demonstrate comprehensive monitoring of nuclear material in storage. Straight-Line is an integrated system of sensors providing information that will enhance the safety, security, and international accountability of stored nuclear material. The goals of this effort are to: (1) Provide the right sensor information to the right user immediately. (2) Reduce the expenses, risks, and frequency of human inspection of the material. (3) Provide trustworthy data to international inspectors to minimize their need to make on site inspections. In pursuit of these goals, Straight-Line unites technology from Sandia's Authenticated Item Monitoring System (AIMS) and other programs to communicate the authenticated status of the monitored item back to central magazine receivers. Straight-Line, however, incorporates several important features not found in previous systems: (1) Information Security -- the ability to collect and safely disseminate both classified and unclassified sensor data to users on a need-to-know basis. (2) Integrate into a single system the monitoring needs of safety, security, and international accountability. (3) Incorporate the use of sensors providing analog or digital output. This paper will present the overall architecture and status of the Straight-Line project

  20. Preferences of AP position of the straight Caucasian facial profile.

    Science.gov (United States)

    Mees, Steven; Jiménez Bellinga, Raúl; Mommaerts, Maurice Y; De Pauw, Guy A M

    2013-12-01

    Several investigators have compared the perception of profile attractiveness between professional and non-professional people, different groups of clinicians, and different ethnic groups. Our aim was to study preferences for facial protrusion in the lateral view for a straight Class I profile and to study the influence of gender, age, sex preference, and profession. Portrait images of one male and one female model with a Class I occlusal relationship were warped into nine different antero-posterior positions. An internet site was established to reach as many people as possible, and a request was sent by email to participate in a scientific experiment. Finally, 1707 Caucasion assessors could be grouped. The preferred male profile is the straight full ante profile. For a feminine facial profile, the straight average and the straight 2/3 ante profiles were perceived as the most attractive. Surgeons tended to give significantly higher scores to attractive (ante) profiles, which correlated strongly with scores of the orthodontists. Whenever possible with combined orthodontic/surgery treatment, straight ante profiles should be aimed for. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Visual straight-ahead preference in saccadic eye movements.

    Science.gov (United States)

    Camors, Damien; Trotter, Yves; Pouget, Pierre; Gilardeau, Sophie; Durand, Jean-Baptiste

    2016-03-15

    Ocular saccades bringing the gaze toward the straight-ahead direction (centripetal) exhibit higher dynamics than those steering the gaze away (centrifugal). This is generally explained by oculomotor determinants: centripetal saccades are more efficient because they pull the eyes back toward their primary orbital position. However, visual determinants might also be invoked: elements located straight-ahead trigger saccades more efficiently because they receive a privileged visual processing. Here, we addressed this issue by using both pro- and anti-saccade tasks in order to dissociate the centripetal/centrifugal directions of the saccades, from the straight-ahead/eccentric locations of the visual elements triggering those saccades. Twenty participants underwent alternating blocks of pro- and anti-saccades during which eye movements were recorded binocularly at 1 kHz. The results confirm that centripetal saccades are always executed faster than centrifugal ones, irrespective of whether the visual elements have straight-ahead or eccentric locations. However, by contrast, saccades triggered by elements located straight-ahead are consistently initiated more rapidly than those evoked by eccentric elements, irrespective of their centripetal or centrifugal direction. Importantly, this double dissociation reveals that the higher dynamics of centripetal pro-saccades stem from both oculomotor and visual determinants, which act respectively on the execution and initiation of ocular saccades.

  2. Straight-Line -- A nuclear material storage information management system

    Energy Technology Data Exchange (ETDEWEB)

    Nilsen, C. [Sandia National Labs., Livermore, CA (United States); Mangan, D. [Sandia National Labs., Albuquerque, NM (United States)

    1995-12-31

    Sandia National Laboratories is developing Straight-Line -- a pilot system to demonstrate comprehensive monitoring of nuclear material in storage. Straight-Line is an integrated system of sensors providing information that will enhance the safety, security, and international accountability of stored nuclear material. The goals of this effort are to (1) Provide the right sensor information to the right user in a timely manner. (2) Reduce the expenses, risks, and frequency of human inspection of the material. (3) Provide trustworthy data to international inspectors to minimize their need to make on site inspections. In pursuit of these goals, Straight-Line unites technology from Sandia`s Authenticated Item Monitoring System (AIMS) and other programs to communicate the authenticated status of the monitored item back to central magazine receivers. Straight-Line, however, incorporates several important features not found in previous systems: (1) Information Security -- the ability to collect and safely disseminate both classified and unclassified sensor data to users on a need-to-know basis. (2) Integrate into a single system the monitoring needs of safety, security, and international accountability. (3) Incorporate the use of sensors providing analog or digital output. This paper will present the overall architecture and status of the Straight-Line project.

  3. Straight-Line: A nuclear material storage information management system

    Energy Technology Data Exchange (ETDEWEB)

    Nilsen, C.; Mangan, D.

    1995-07-01

    Sandia National Laboratories is developing Straight-Line -- a pilot system to demonstrate comprehensive monitoring of nuclear material in storage. Straight-Line is an integrated system of sensors providing information that will enhance the safety, security, and international accountability of stored nuclear material. The goals of this effort are to: (1) Provide the right sensor information to the right user immediately. (2) Reduce the expenses, risks, and frequency of human inspection of the material. (3) Provide trustworthy data to international inspectors to minimize their need to make on site inspections. In pursuit of these goals, Straight-Line unites technology from Sandia`s Authenticated Item Monitoring System (AIMS) and other programs to communicate the authenticated status of the monitored item back to central magazine receivers. Straight-Line, however, incorporates several important features not found in previous systems: (1) Information Security -- the ability to collect and safely disseminate both classified and unclassified sensor data to users on a need-to-know basis. (2) Integrate into a single system the monitoring needs of safety, security, and international accountability. (3) Incorporate the use of sensors providing analog or digital output. This paper will present the overall architecture and status of the Straight-Line project.

  4. Straight eye for the gay guy: composing queerness.

    Science.gov (United States)

    Alexander, Jonathan

    2010-01-01

    Drawing on the work of Didier Eribon and his theorization of the construction of gay male subjectivity, this article examines different "texts," broadly defined, that grapple specifically with straight men attempting to represent male homosexuality: Norman Mailer's essay, "The Homosexual Villain"; the Bravo reality television series Boy Meets Boy, and Michael Griffith's short story, "Hooper Gets a Perm." These texts represent attempts by straight authors to grapple with queer experience in ways that move the imagination of queers beyond simple stereotypes or uncritical explorations of the sexual "other." In the process of examining these texts, the following questions are addressed: What happens when a straight man attempts to represent a gay man? Does he "get it right," and is such a question even useful? More specifically, what is the value in having straights imagine queerness? Is such an imagining possible? Is such desirable? And, if so, what are the contours of such an imagining-as well as its possibilities and limitations, pedagogically, personally, and politically? Ultimately, I contend that the straight imagining of queerness offers rich potential for mutual understanding; furthermore, attempting to understand what goes into the making of those representations tells us much about how queerness circulates in our culture as a subject, a figure of discussion, contention, and representation.

  5. Straight-Line -- A nuclear material storage information management system

    International Nuclear Information System (INIS)

    Nilsen, C.; Mangan, D.

    1995-01-01

    Sandia National Laboratories is developing Straight-Line -- a pilot system to demonstrate comprehensive monitoring of nuclear material in storage. Straight-Line is an integrated system of sensors providing information that will enhance the safety, security, and international accountability of stored nuclear material. The goals of this effort are to (1) Provide the right sensor information to the right user in a timely manner. (2) Reduce the expenses, risks, and frequency of human inspection of the material. (3) Provide trustworthy data to international inspectors to minimize their need to make on site inspections. In pursuit of these goals, Straight-Line unites technology from Sandia's Authenticated Item Monitoring System (AIMS) and other programs to communicate the authenticated status of the monitored item back to central magazine receivers. Straight-Line, however, incorporates several important features not found in previous systems: (1) Information Security -- the ability to collect and safely disseminate both classified and unclassified sensor data to users on a need-to-know basis. (2) Integrate into a single system the monitoring needs of safety, security, and international accountability. (3) Incorporate the use of sensors providing analog or digital output. This paper will present the overall architecture and status of the Straight-Line project

  6. Intrarenal purinergic signaling in the control of renal tubular transport

    DEFF Research Database (Denmark)

    Prætorius, Helle; Leipziger, Jens Georg

    2010-01-01

    Renal tubular epithelial cells receive hormonal input that regulates volume and electrolyte homeostasis. In addition, numerous intrarenal, local signaling agonists have appeared on the stage of renal physiology. One such system is that of intrarenal purinergic signaling. This system involves all......-reaching advances indicate that ATP is often used as a local transmitter for classical sensory transduction. This transmission apparently also applies to sensory functions in the kidney. Locally released ATP is involved in sensing of renal tubular flow or in detecting the distal tubular load of NaCl at the macula...

  7. Perfis tubulares : aspectos arquitetônicos e estruturais.

    OpenAIRE

    Gerken, Fernanda de Sousa

    2003-01-01

    Programa de Pós Graduação em Engenharia Civil. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto. O presente trabalho tem como objetivo apresentar uma visão geral da utilização das estruturas tubulares no contexto da evolução das estruturas metálicas em geral, com destaque para o estudo de obras que mostram o estado da arte da construção tubular no Brasil. A utilização dos perfis tubulares estruturais é abordada tanto do ponto de vista da ...

  8. Endovascular Tubular Stent-Graft Placement for Isolated Iliac Artery Aneurysms

    International Nuclear Information System (INIS)

    Okada, Takuya; Yamaguchi, Masato; Kitagawa, Atsushi; Kawasaki, Ryota; Nomura, Yoshikatsu; Okita, Yutaka; Sugimura, Kazuro; Sugimoto, Koji

    2012-01-01

    Purpose: To evaluate the safety, efficacy, and mid-term outcomes of endovascular tubular stent-graft placement for repair of isolated iliac artery aneurysms (IAAs). Materials and Methods: Between January 2002 and March 2010, 20 patients (7 women and 13 men; mean age 74 years) underwent endovascular repair of 22 isolated IAAs. Two patients underwent endovascular repair for bilateral aneurysms. Ten para-anastomotic aneurysms (45%) developed after open abdominal aortic aneurysm (AAA) repair with an aorto-iliac graft, and 12 were true aneurysms (55%). Eleven straight and 11 tapered stent-grafts were placed. Contrast-enhanced computed tomography (CT) was performed to detect complications and evaluate aneurysmal shrinkage at week 1, 3, 6, and 12 months and once every year thereafter. Non–contrast-enhanced CT was performed in seven patients with chronic kidney disease. Results: All procedures were successful, without serious complications, during the mean (range) follow-up period of 746 days (47–2651). Type II endoleak not requiring treatment was noted in one patient. The mean (SD) diameters of the true and para-anastomotic aneurysms significantly (p < 0.05) decreased from 42.0 (9.3) to 36.9 (13.6) mm and from 40.1 (13.0) to 33.6 (15.8) mm, respectively; the mean (SD) shrinkage rates were 15.1% (20.2%) and 18.9% (22.4%), respectively. The primary patency rate was 100%, and no secondary interventions were required. Four patients (21%) developed transient buttock claudication, and one patient (5%) developed colorectal ischaemia, which was treated conservatively. Conclusion: Endovascular tubular stent-graft placement for the repair of isolated IAAs is safe and efficacious. Tapered stent-grafts of various sizes are required for accurate placement.

  9. A mathematical model for camera calibration based on straight lines

    Directory of Open Access Journals (Sweden)

    Antonio M. G. Tommaselli

    2005-12-01

    Full Text Available In other to facilitate the automation of camera calibration process, a mathematical model using straight lines was developed, which is based on the equivalent planes mathematical model. Parameter estimation of the developed model is achieved by the Least Squares Method with Conditions and Observations. The same method of adjustment was used to implement camera calibration with bundles, which is based on points. Experiments using simulated and real data have shown that the developed model based on straight lines gives results comparable to the conventional method with points. Details concerning the mathematical development of the model and experiments with simulated and real data will be presented and the results with both methods of camera calibration, with straight lines and with points, will be compared.

  10. Bent versus straight tips in micropulsed longitudinal phacoemulsification.

    Science.gov (United States)

    Stagg, Brian C; Gupta, Isha; Cahoon, Judd; Ronquillo, Cecinio; Shi, Dallas; Zaugg, Brian; Gardiner, Gareth; Barlow, William R; Pettey, Jeff H; Aabid Farukhi, M; Jensen, Jason; Olson, Randall J

    2015-10-01

    The aim of this study was to evaluate bent and straight phacoemulsification tips to determine which tip is more efficient in removal of lens fragments, using micropulsed longitudinal ultrasound in phacoemulsification. In vitro laboratory study. The John A. Moran Eye Center Laboratories, University of Utah, Salt Lake City, Utah, was the study setting. Pig lenses hardened in a manner comparable with dense human cataracts were cut into 2-mm cubes and removed with micropulsed longitudinal ultrasound using settings previously shown to be optimally efficient (6 milliseconds on and 6 milliseconds off for a bent tip). To verify this time as most efficient for a straight tip, we also tested times of 5, 6, and 7 milliseconds time on and off. The tips were either straight or with a 20-degree bend. Twenty cubes were used for each comparative run. For the straight tip, 6 milliseconds on (1.56 ± 0.815 seconds) was significantly more efficient than 7 milliseconds on (2.45 ± 1.56 seconds, p = 0.001) and not significantly more efficient than 5 milliseconds on (1.69 ± 0.86 seconds, p = 0.43). Five milliseconds off time (1.45 ± 0.76s) was more efficient than 6 milliseconds (2.06 ± 1.37 seconds, p = 0.004) and 7 milliseconds off (2.18 ± 1.24s, p = 0.001). The straight tip was more efficient than the bent tip (1.38 ± 0.83 versus 2.93 ± 2.14 seconds, p = 0.006). Results are contrary to accepted common belief. Micropulsed longitudinal phacoemulsification is more efficient with a straight rather than a bent tip. Copyright © 2015 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  11. Radical heterosexuality: Straight teacher activism in schools : Does ally-led activism work?

    Directory of Open Access Journals (Sweden)

    Leigh Potvin

    2016-06-01

    Here, I explore the efficacy of straight teacher allies, the importance of understanding straight privilege, and the significance of radical heterosexuality for straight people doing LGBTQ activism. Relying on queer theory and decolonizing/Indigenous queer theory, I argue that it is necessary for straight teachers to acknowledge their straight privilege in order to challenge homophobia's companions: heterosexism and heteronormativity. In addressing the latter two covert forms of oppression in schools, teachers and students could shift into deeper, more effective resistance measures.

  12. Scenario analysis of large scale algae production in tubular photobioreactors

    NARCIS (Netherlands)

    Slegers, P.M.; Beveren, van P.J.M.; Wijffels, R.H.; Straten, van G.; Boxtel, van A.J.B.

    2013-01-01

    Microalgae productivity in tubular photobioreactors depends on algae species, location, tube diameter, biomass concentration, distance between tubes and for vertically stacked systems, the number of horizontal tubes per stack. A simulation model for horizontal and vertically stacked horizontal

  13. Hot Firing of a Full Scale Copper Tubular Combustion Chamber

    National Research Council Canada - National Science Library

    Cooley, C

    2002-01-01

    This paper describes the chamber design and hot firing test results for a full-scale copper tubular combustion chamber that has future application in a high-thrust, upper-stage expander cycle engine...

  14. Genetics Home Reference: renal tubular acidosis with deafness

    Science.gov (United States)

    ... adults with renal tubular acidosis with deafness have short stature, and many develop kidney stones. The metabolic acidosis ... enlarged vestibular aqueduct, can be seen with medical imaging. The vestibular aqueduct is a bony canal that ...

  15. Solar Heating Systems with Evacuated Tubular Solar Collector

    DEFF Research Database (Denmark)

    Qin, Lin; Furbo, Simon

    1998-01-01

    Recently different designed evacuated tubular solar collectors were introduced on the market by different Chinese companies. In the present study, investigations on the performance of four different Chinese evacuated tubular collectors and of solar heating systems using these collectors were...... carried out, employing both laboratory test and theoretical calculations. The collectors were tested in a small solar domestic hot water (SDHW) system in a laboratory test facility under realistic conditions. The yearly thermal performance of solar heating systems with these evacuated tubular collectors......, as well as with normal flat-plate collectors was calculated under Danish weather conditions. It is found that, for small SDHW systems with a combi tank design, an increase of 25% -55% net utilized solar energy can be achieved by using these evacuated tubular collectors instead of normal flat...

  16. Tubular forms of papova viruses in human laryngeal papilloma.

    Science.gov (United States)

    Arnold, W

    1979-01-01

    In two cases of recurrent laryngeal papillomatosis tubular forms of papova viruses could be observed. The same material revealed the close relation between nuclear chromatine and the release of particles, as well as a capsomere like substructure of the virions.

  17. Production of short straight sections hits 100 units

    CERN Multimedia

    2005-01-01

    The 100th short straight section for the Large Hadron Collider was assembled at CERN at the beginning of April. These units combine superconducting quadrupoles and other multipole corrector magnets, housed in their cryostats, which are used to guide, focus and fine-tune the beam in the LHC. Building 904, where the 474 short straight sections are being assembled, is often called "Lego Land" by the workers, with a touch of humor and pride because of the wide variety of these sets of magnets and cryostats .

  18. Commissioning of the cryogenics of the LHC long straight sections

    International Nuclear Information System (INIS)

    Perin, A.; Casas-Cubillos, J.; Claudet, S.; Darve, C.; Ferlin, G.; Millet, F.; Parente, C.; Rabehl, R.; Soubiran, M.; van Weelderen, R.; Wagner, U.

    2010-01-01

    The LHC is made of eight circular arcs interspaced with eight Long Straight Sections (LSS). Most powering interfaces to the LHC are located in these sections where the particle beams are focused and shaped for collision, cleaning and acceleration. The LSSs are constituted of several unique cryogenic devices and systems like electrical feed-boxes, standalone superconducting magnets, superconducting links, RF cavities and final focusing superconducting magnets. This paper presents the cryogenic commissioning and the main results obtained during the first operation of the LHC Long Straight Sections.

  19. A generalized, periodic nonlinearity-reduced interferometer for straightness measurements

    International Nuclear Information System (INIS)

    Wu Chienming

    2008-01-01

    Periodic nonlinearity is a systematic error limiting the accuracy of displacement measurements at the nanometer level. However, an interferometer with a displacement measurement accuracy of less than 1 nm is required in nanometrology and in fundamental scientific research. To meet this requirement, a generalized, periodic nonlinearity-reduced interferometer, based on three construction principles has been developed for straightness measurements. These three construction principles have resulted in an interferometer with a highly stable design with reduced periodic nonlinearity. Verifications by a straightness interferometer have demonstrated that the periodic nonlinearity was less than 40 pm. The results also demonstrate that the interferometer design is capable of subnanometer accuracy and is useful in nanometrology

  20. Commissioning of the Cryogenics of the LHC Long Straight Sections

    CERN Document Server

    Perin, A; Claudet, S; Darve, C; Ferlin, G; Millet, F; Parente, C; Rabehl, R; Soubiran, M; van Weelderen, R; Wagner, U

    2010-01-01

    The LHC is made of eight circular arcs interspaced with eight Long Straight Sections (LSS). Most powering interfaces to the LHC are located in these sections where the particle beams are focused and shaped for collision, cleaning and acceleration. The LSSs are constituted of several unique cryogenic devices and systems like electrical feed-boxes, standalone superconducting magnets, superconducting links, RF cavities and final focusing superconducting magnets. This paper presents the cryogenic commissioning and the main results obtained during the first operation of the LHC Long Straight Sections.

  1. The Fourier transform of tubular densities

    KAUST Repository

    Prior, C B

    2012-05-18

    We consider the Fourier transform of tubular volume densities, with arbitrary axial geometry and (possibly) twisted internal structure. This density can be used to represent, among others, magnetic flux or the electron density of biopolymer molecules. We consider tubes of both finite radii and unrestricted radius. When there is overlap of the tube structure the net density is calculated using the super-position principle. The Fourier transform of this density is composed of two expressions, one for which the radius of the tube is less than the curvature of the axis and one for which the radius is greater (which must have density overlap). This expression can accommodate an asymmetric density distribution and a tube structure which has non-uniform twisting. In addition we give several simpler expressions for isotropic densities, densities of finite radius, densities which decay at a rate sufficient to minimize local overlap and finally individual surfaces of the tube manifold. These simplified cases can often be expressed as arclength integrals and can be evaluated using a system of first-order ODEs. © 2012 IOP Publishing Ltd.

  2. A tubular electrode for radiofrequency ablation therapy

    KAUST Repository

    Antunes, Carlos Lemos Lemos Lemos

    2012-07-06

    Purpose – Due to its good mechanical and biocompatibility characteristics, nitinol SEMS is a popular endoprothesis used for relieving stricture problems in hollow organs due to carcinomas. Besides its mechanical application, SEMS can be regarded as well as potential electrode for performing RF ablation therapy on the tumor. The purpose of this work is to perform numerical and experimental analyses in order to characterize the lesion volume induced in biological tissue using this kind of tubular electrode. Design/methodology/approach – Data concerning electrical conductivity and dimension of the damaged tissue after RF ablation procedure were obtained from ex vivo samples. Next, numerical models using 3D finite element method were obtained reassembling the conditions considered at experimentation setup and results were compared. Findings – Numerical and experimental results show that a regular volume of damaged tissue can be obtained considering this type of electrode. Also, results obtained from numerical simulation are close to those obtained by experimentation. Originality/value – SEMSs, commonly used as devices to minimize obstruction problems due to the growth of tumors, may still be considered as an active electrode for RF ablation procedures. A method considering this observation is presented in this paper. Also, numerical simulation can be regarded in this case as a tool for determining the lesion volume.

  3. The Fourier transform of tubular densities

    International Nuclear Information System (INIS)

    Prior, C B; Goriely, A

    2012-01-01

    We consider the Fourier transform of tubular volume densities, with arbitrary axial geometry and (possibly) twisted internal structure. This density can be used to represent, among others, magnetic flux or the electron density of biopolymer molecules. We consider tubes of both finite radii and unrestricted radius. When there is overlap of the tube structure the net density is calculated using the super-position principle. The Fourier transform of this density is composed of two expressions, one for which the radius of the tube is less than the curvature of the axis and one for which the radius is greater (which must have density overlap). This expression can accommodate an asymmetric density distribution and a tube structure which has non-uniform twisting. In addition we give several simpler expressions for isotropic densities, densities of finite radius, densities which decay at a rate sufficient to minimize local overlap and finally individual surfaces of the tube manifold. These simplified cases can often be expressed as arclength integrals and can be evaluated using a system of first-order ODEs. (paper)

  4. Inflatable Tubular Structures Rigidized with Foams

    Science.gov (United States)

    Tinker, Michael L.; Schnell, Andrew R.

    2010-01-01

    Inflatable tubular structures that have annular cross sections rigidized with foams, and the means of erecting such structures in the field, are undergoing development. Although the development effort has focused on lightweight structural booms to be transported in compact form and deployed in outer space, the principles of design and fabrication are also potentially applicable to terrestrial structures, including components of ultralightweight aircraft, lightweight storage buildings and shelters, lightweight insulation, and sales displays. The use of foams to deploy and harden inflatable structures was first proposed as early as the 1960s, and has been investigated in recent years by NASA, the U.S. Air Force Research Laboratory, industry, and academia. In cases of deployable booms, most of the investigation in recent years has focused on solid cross sections, because they can be constructed relatively easily. However, solid-section foam-filled booms can be much too heavy for some applications. In contrast, booms with annular cross sections according to the present innovation can be tailored to obtain desired combinations of stiffness and weight through choice of diameters, wall thicknesses, and foam densities. By far the most compelling advantage afforded by this innovation is the possibility of drastically reducing weights while retaining or increasing the stiffnesses, relative to comparable booms that have solid foamfilled cross sections. A typical boom according to this innovation includes inner and outer polyimide film sleeves to contain foam that is injected between them during deployment.

  5. Tubular Initial Conditions and Ridge Formation

    Directory of Open Access Journals (Sweden)

    M. S. Borysova

    2013-01-01

    Full Text Available The 2D azimuth and rapidity structure of the two-particle correlations in relativistic A+A collisions is altered significantly by the presence of sharp inhomogeneities in superdense matter formed in such processes. The causality constraints enforce one to associate the long-range longitudinal correlations observed in a narrow angular interval, the so-called (soft ridge, with peculiarities of the initial conditions of collision process. This study's objective is to analyze whether multiform initial tubular structures, undergoing the subsequent hydrodynamic evolution and gradual decoupling, can form the soft ridges. Motivated by the flux-tube scenarios, the initial energy density distribution contains the different numbers of high density tube-like boost-invariant inclusions that form a bumpy structure in the transverse plane. The influence of various structures of such initial conditions in the most central A+A events on the collective evolution of matter, resulting spectra, angular particle correlations and vn-coefficients is studied in the framework of the hydrokinetic model (HKM.

  6. Hereditary Hypokalemic salt-losing tubular disorders

    International Nuclear Information System (INIS)

    Peters, M.; Konard, M.; Seyberth, H.W.

    2003-01-01

    The inherited hypokalemic tubular disorders are frequently summarized under the heading Bartter Syndrome since they share several clinical and biochemical findings such as renal salt wasting, hypokalemic metabolic alkalosis, normal blood pressure despite hypereninemic hyperaldosteronism and hyperplasia of the juxtaglomerular apparatus. However, careful characterization of the clinical phenotype and correlation with the clinical phenotype and the correlation with the underlying molecular basis justifies the differentiation into at least four distinct disease entities: (i) the hyperprostaglandin E syndrome or antenatal variant of Bartter syndrome (HPS/aBS), which is caused by mutations in either the Na-K-2Cl cotransporter or the potassium channel of the medullary thick ascending limb of Henle's loop; (ii) the HPS/aBS with sensorineural deafness which results from inactivating mutation in the Barttin beta-subunit of the renal chloride channels; (iii) the classic Bartter syndrome caused by mutations in the chloride channel of the distal nephron; and (iv)Gitelman's variant of Bartter syndrome which is caused by mutations of the Na-Cl cotransporter of the distal convoluted tubule. This review will summarize the clinical characteristics of these diseases and progress recently made in the identification of the underlying molecular defects that will hopefully add to the current knowledge of the pathogenesis of these diseases. (author)

  7. Modeling constrained sintering of bi-layered tubular structures

    DEFF Research Database (Denmark)

    Tadesse Molla, Tesfaye; Kothanda Ramachandran, Dhavanesan; Ni, De Wei

    2015-01-01

    Constrained sintering of tubular bi-layered structures is being used in the development of various technologies. Densification mismatch between the layers making the tubular bi-layer can generate stresses, which may create processing defects. An analytical model is presented to describe the densi...... and thermo-mechanical analysis. Results from the analytical model are found to agree well with finite element simulations as well as measurements from sintering experiment....

  8. Electrolyte composition of renal tubular cells in gentamicin nephrotoxicity

    International Nuclear Information System (INIS)

    Matsuda, O.; Beck, F.X.; Doerge, A.T.; Thurau, K.

    1988-01-01

    The effect of long-term gentamicin administration on sodium, potassium, chloride and phosphorus concentrations was studied in individual rat renal tubular cells using electron microprobe analysis. Histological damage was apparent only in proximal tubular cells. The extent of damage was only mild after 7 days of gentamicin administration (60 mg/kg body wt/day) but much more pronounced after 10 days. GFR showed a progressive decline during gentamicin treatment. In non-necrotic proximal tubular cells, sodium was increased from 14.6 +/- 0.3 (mean +/- SEM) in controls to 20.6 +/- 0.4 after 7 and 22.0 +/- 0.8 mmol/kg wet wt after 10 days of gentamicin administration. Chloride concentration was higher only after 10 days (20.6 +/- 0.6 vs. 17.3 +/- 0.2 mmol/kg wet wt). Both cell potassium and phosphorus concentrations were diminished by 6 and 15, and by 8 and 25 mmol/kg wet wt after 7 and 10 days of treatment, respectively. In contrast, no major alterations in distal tubular cell electrolyte concentrations could be observed after either 7 or 10 days of gentamicin administration. As in proximal tubular cells, distal tubular cell phosphorus concentrations were, however, lowered by gentamicin treatment. These results clearly indicate that gentamicin exerts its main effect on proximal tubular cells. Decreased potassium and increased sodium and chloride concentrations were observed in proximal tubular cells exhibiting only mild histological damage prior to the onset of advanced tissue injury. Necrotic cells, on the other hand, showed widely variable intracellular electrolyte concentration patterns

  9. The ghost of Nora Batty: A qualitative exploration of the impact of footwear, bandaging and hosiery interventions in chronic wound care.

    Science.gov (United States)

    Madden, Mary

    2015-09-01

    To explore the impact of footwear, bandaging and hosiery interventions in the everyday lives of women and men undergoing treatment for chronic, complex wounds in a city in England, UK. This study draws on data generated in semi-structured interviews with patients exploring outcomes and impacts of undergoing treatment for leg and foot ulcers undertaken as part of a UK National Institute for Health Research funded study. Footwear, bandaging and hosiery are explored here as aspects of material culture, not only in functional terms as a treatment supporting or hindering healing but also as part of the means by which people receiving treatment for two of the most common complex, chronic wounds, leg ulcers and foot ulcers, negotiate and understand their embodied selves in everyday life. Physical and social discomfort associated with interventions can lead to ambivalence about effectiveness. Not being able to dress appropriately impacts on the ability of people to feel comfortable and take part in special occasions and everyday events. In this context, the removal of bandaging or refusal to wear support hosiery which may be viewed as 'non-compliance' by a health professional may feel like a strategy of self-care or self-preservation from a patient perspective. The study of material culture explores how inanimate objects work and how they are worked with in carrying out social functions, regulating social relations and giving symbolic meaning to human activity. The interviews show some of the ways in which footwear, hosiery and bandaging play a role in controlling the boundaries between the private (wounded and potentially socially unacceptable smelly, leaky, embodied), self and the public presentation of self. © The Author(s) 2015.

  10. Luminal nucleotides are tonic inhibitors of renal tubular transport

    DEFF Research Database (Denmark)

    Leipziger, Jens Georg

    2011-01-01

    PURPOSE OF REVIEW: Extracellular ATP is an essential local signaling molecule in all organ systems. In the kidney, purinergic signaling is involved in an array of functions and this review highlights those of relevance for renal tubular transport. RECENT FINDINGS: Purinergic receptors are express...... discovered as an important signaling compartment in which local purinergic signaling determines an inhibitory tone for renal tubular transport. Blocking components of this system leads to tubular hyper-absorption, volume retention and elevated blood pressure.......PURPOSE OF REVIEW: Extracellular ATP is an essential local signaling molecule in all organ systems. In the kidney, purinergic signaling is involved in an array of functions and this review highlights those of relevance for renal tubular transport. RECENT FINDINGS: Purinergic receptors are expressed...... in all renal tubular segments and their stimulation generally leads to transport inhibition. Recent evidence has identified the tubular lumen as a restricted space for purinergic signaling. The concentrations of ATP in the luminal fluids are sufficiently high to inflict a tonic inhibition of renal...

  11. [Comparison of efficacy of heel ulcer prevention between classic padded bandage and polyurethane heel in a medium-stay hospital: randomized controlled trial].

    Science.gov (United States)

    Ferrer Solà, Marta; Espaulella Panicot, Joan; Altimires Roset, Jacint; Ylla-Català Borè, Elisenda; Moreno Susi, María

    2013-01-01

    The aim of the study is to determine the incidence of heel pressure ulcers (UPPT) and to compare the two systems for UPPT prevention: classic padded bandage and polyurethane heel. Prospective intervention study in a medium-long hospital stay of all people admitted that had no UPPT but had a risk of UPPT according to the Braden Scale or clinical judgment. The patients were randomized to prevention with classic padded bandage or polyurethane heel. The outcome variable was the incidence of UPPT for each study group, which was recorded every 15 days or when there were clinical changes. Of the 940 patients evaluated, 409 with a mean age of 80.5 years and 59.1% women,were included in the study. Of these, 78% had Barthel score ≤30; 28.6% dementia; delirium 37.6%; 27.6% diabetes; and 19.6% other UPP. The overall incidence was 2.9% UPPT; 2.49% in the classic padded bandage and 3.37% in the polyurethane heel group (p=0.82). No statistically significant differences were observed between the group with the classical dressing and the group with the polyurethane heel dressing. The use of multiple measures to prevent UPPT achieved a low incidence of these. Copyright © 2011 SEGG. Published by Elsevier Espana. All rights reserved.

  12. Comparison of the effectiveness of complex decongestive therapy and compression bandaging as a method of treatment of lymphedema in the elderly

    Directory of Open Access Journals (Sweden)

    Zasadzka E

    2018-05-01

    Full Text Available Ewa Zasadzka,1 Tomasz Trzmiel,1 Maria Kleczewska,2 Mariola Pawlaczyk1 1Department of Geriatric Medicine and Gerontology, Karol Marcinkowski University of Medical Sciences, Poznan, Poland; 2Day Rehabilitation Center, Hospicjum Palium, Poznań, Poland Background: Lymphedema is a chronic condition which significantly lowers the quality of patient life, particularly among elderly populations, whose mobility and physical function are often reduced. Objectives: The aim of the study was to compare the effectiveness of multi-layer compression bandaging (MCB and complex decongestive therapy (CDT, and to show that MCB is a cheaper, more accessible and less labor intensive method of treating lymphedema in elderly patients. Patients and methods: The study included 103 patients (85 women and 18 men aged ≥60 years, with unilateral lower limb lymphedema. The subjects were divided into two groups: 50 treated with CDT and 53 with MCB. Pre- and post-treatment BMI, and average and maximum circumference of the edematous extremities were analyzed. Results: Reduction in swelling in both groups was achieved after 15 interventions. Both therapies demonstrated similar efficacy in reducing limb volume and circumference, but MCB showed greater efficacy in reducing the maximum circumference. Conclusion: Compression bandaging is a vital component of CDT. Maximum lymphedema reduction during therapy and maintaining its effect cannot be achieved without it. It also demonstrates its effectiveness as an independent method, which can reduce therapy cost and accessibility. Keywords: lymphedema, elderly, therapy, compression bandaging

  13. Linear Motion Systems. A Modular Approach for Improved Straightness Performance

    NARCIS (Netherlands)

    Nijsse, G.J.P.

    2001-01-01

    This thesis deals with straight motion systems. A modular approach has been applied in order to find ways to improve the performance. The main performance parameters that are considered are position accuracy, repeatability and, to a lesser extent, cost. Because of the increasing requirements to

  14. Modeling plasma flow in straight and curved solenoids

    International Nuclear Information System (INIS)

    Boercker, D.B.; Sanders, D.M.; Storer, J.; Falabella, S.

    1991-01-01

    The ''flux-tube'' model originated by Morozov is a very simple and numerically efficient method for simulating ion motion in plasma filters. In order to test its utility as a design tool, we compare the predictions of the model to recent experimental measurements of plasma flow in both straight and curved solenoids

  15. Steam cracking of hydrocarbons 3. Straight-run naphtha

    NARCIS (Netherlands)

    Bajus, M.; Vesely, V.; Leclercq, P.A.; Rijks, J.A.

    1980-01-01

    Steam cracking of straight-run naphtha from Romashkino crude oil was investigated in quartz and stainless steel reactors with a relatively large ratio of Inner surface to volume. The experiments were performed at atmospheric pressure at 780-800 OC for starting ratios of steam to naphtha between 0.5

  16. Setting the Record Straight on "High-Yield" Strategies

    Science.gov (United States)

    Marzano, Robert J.

    2009-01-01

    Widely credited with proposing nine "high-yield" instructional strategies, author Robert J. Marzano sets the record straight about the broader number of strategies identified by the research. He provides a list of 41 strategies and suggests more nuanced ways of using, observing, and evaluating them. (Contains 1 figure.)

  17. The Dugdale solution for two unequal straight cracks weakening

    Indian Academy of Sciences (India)

    A crack arrest model is proposed for an infinite elastic perfectly-plastic plate weakened by two unequal, quasi-static, collinear straight cracks. The Dugdale model solution is obtained for the above problem when the developed plastic zones are subjected to normal cohesive quadratically varying yield point stress. Employing ...

  18. Body image in gay and straight men: a qualitative study.

    Science.gov (United States)

    Morgan, John F; Arcelus, Jon

    2009-11-01

    Recent research has emphasized vulnerability to eating disorders in gay men, with calls for research on causality, cultural factors and focus on a younger age cohort. This study aimed to examine body image and related eating behaviours in younger gay and straight men. Qualitative study using a sample of gay and straight male university students, applying audiotaped and transcribed depth interview subjected to interpretative phenomenological analysis. Fifteen young men (18-24) with a spectrum of sexual orientation (gay, straight and bisexual) agreed to participate. Five dominant categories emerged: body image ideal, external influences, perception of body image, dieting, mechanisms for modification (diet, exercise, cosmetics) and sexual orientation. Health and aesthetic ideals appear less divorced for young men than women, offering some degree of protection from eating disorders. Nonetheless there is widespread body dissatisfaction. Media and social influences are powerful, particularly for single gay men, but the study suggests fewer differences than similarities between gay and straight men. Copyright (c) 2009 John Wiley & Sons, Ltd and Eating Disorders Association.

  19. Stereotactic biopsy of cerebellar lesions: straight versus oblique frame positioning.

    Science.gov (United States)

    Quick-Weller, Johanna; Brawanski, Nina; Dinc, Nazife; Behmanesh, Bedjahn; Kammerer, Sara; Dubinski, Daniel; Seifert, Volker; Marquardt, Gerhard; Weise, Lutz

    2017-10-26

    Biospies of brain lesions with unknown entity are an everyday procedure among many neurosurgical departments. Biopsies can be performed frame-guided or frameless. However, cerebellar lesions are a special entity with a more complex approach. All biopsies in this study were performed stereotactically frame guided. Therefore, only biopsies of cerebellar lesions were included in this study. We compared whether the frame was attached straight versus oblique and we focused on diagnostic yield and complication rate. We evaluated 20 patients who underwent the procedure between 2009 and 2017. Median age was 56.5 years. 12 (60%) Patients showed a left sided lesion, 6 (30%) showed a lesion in the right cerebellum and 2 (10%) patients showed a midline lesion. The stereotactic frame was mounted oblique in 12 (60%) patients and straight in 8 (40%) patients. Postoperative CT scan showed small, clinically silent blood collection in two (10%) of the patients, one (5%) patient showed haemorrhage, which caused a hydrocephalus. He received an external ventricular drain. In both patients with small haemorrhage the frame was positioned straight, while in the patient who showed a larger haemorrhage the frame was mounted oblique. In all patients a final histopathological diagnosis was established. Cerebellar lesions of unknown entity can be accessed transcerebellar either with the stereotactic frame mounted straight or oblique. Also for cerebellar lesions the procedure shows a high diagnostic yield with a low rate of severe complications, which need further treatment.

  20. A Straight-Talk Survival Guide for Colleges

    Science.gov (United States)

    Facione, Peter A.

    2009-01-01

    Times are very tough. The great majority of colleges are looking at 2009 and 2010 and beyond, in anticipation of the deepest budget cuts in more than a generation. But as bad as the financial situation may be, colleges can survive if they take swift and strong emergency action. It is time for some straight talk, starting with the realization that…

  1. A new straight accelerator tube with U diaphragm

    International Nuclear Information System (INIS)

    Liu Jinhong; Lai Weiquan; Deng Yushen; Zhang Jidong

    1994-01-01

    After calculating the potential distribution and the particle trajectories in electrostatic accelerator tubes, a new straight tube with U diaphragm to suppress secondary particles is proposed. It's properties are demonstrated by the high voltage tests and the γ-rays measurements in the accelerator

  2. Cardiorespiratory and metabolic responses during straight and bent knee cycling.

    Science.gov (United States)

    Mandroukas, K; Angelopoulou, N; Christoulas, K; Vrabas, I S

    2000-06-01

    This study examined the influence of knee angle on the cardiorespiratory system loading during submaximal and maximal stationary cycle ergometry. Experimental design and participants: eighteen untrained women (age: 21+/-1.88 years, weight: 57+/-5.75 kg, height: 165+/-5.03 cm, values are mean+/-SD) volunteered as subjects and underwent two-cycle ergometer incremental (Jaeger ER900) tests: 1) straight knee (180 degrees), 2) bent knee (140 degrees). oxygen uptake (VO2), ventilation (VE) and respiratory exchange ratio (RER) were measured continuously during each test using an open circuit spirometry and blood lactate concentration was determined by means of an enzymatic method. Comparing cycling with "straight knee" to cycling with "bent knee" at 50 W, heart rate (HR), V(E) and VO2 were significantly higher (10.6%, 12.5%, 17.8%). At 100 W, blood lactate was significantly lower (10.8%) while VO2 and RER was higher (5.5%, 7.1%). During maximal exercise, the total exercise time was significantly longer (11.2%) and VE, VO2 and HR were significantly higher during cycling with "straight knee" compared to cycling with "bent knee". No significant difference in peak lactate was evident between the two sitting positions. The results of this study indicate that cycling with bent knee requires lower oxygen uptake while pedaling with straight knee is the only way to reach VO2max during cycle testing, since the cardiorespiratory system is fully taxed.

  3. Clinical and cost-effectiveness of compression hosiery versus compression bandages in treatment of venous leg ulcers (Venous leg Ulcer Study IV, VenUS IV): a randomised controlled trial.

    Science.gov (United States)

    Ashby, Rebecca L; Gabe, Rhian; Ali, Shehzad; Adderley, Una; Bland, J Martin; Cullum, Nicky A; Dumville, Jo C; Iglesias, Cynthia P; Kang'ombe, Arthur R; Soares, Marta O; Stubbs, Nikki C; Torgerson, David J

    2014-03-08

    Drawbacks exist with the standard treatment (four-layer compression bandages) for venous leg ulcers. We have therefore compared the clinical effectiveness and cost-effectiveness of two-layer compression hosiery with the four-layer bandage for the treatment of such ulcers. We undertook this pragmatic, open, randomised controlled trial with two parallel groups in 34 centres in England and Northern Ireland. The centres were community nurse teams or services, family doctor practices, leg ulcer clinics, tissue viability clinics or services, and wound clinics. Participants were aged 18 years or older with a venous leg ulcer and an ankle brachial pressure index of at least 0·8, and were tolerant of high compression. We randomly allocated participants (1:1) to receive two-layer compression hosiery or a four-layer bandage, using a remote randomisation service and prevalidated computer randomisation program. Participants were stratified by ulcer duration and ulcer area with permuted blocks (block sizes four and six). The primary endpoint was time to ulcer healing, with a maximum follow-up of 12 months. Although participants and health-care providers were not masked to treatment allocation, the primary endpoint was measured by masked assessment of photographs. Primary analysis was intention to treat with Cox regression, with adjustment for ulcer area, ulcer duration, physical mobility, and centre. This trial is registered with the ISRCTN register, number ISRCTN49373072. We randomly allocated 457 participants to the two treatment groups: 230 to two-layer hosiery and 227 to the four-layer bandage, of whom 453 (230 hosiery and 223 bandage) contributed data for analysis. Median time to ulcer healing was 99 days (95% CI 84-126) in the hosiery group and 98 days (85-112) in the bandage group, and the proportion of ulcers healing was much the same in the two groups (70·9% hosiery and 70·4% bandage). More hosiery participants changed their allocated treatment (38·3% hosiery vs 27

  4. Intra-pelvic pressure changes after pelvic fracture: A cadaveric study quantifying the effect of a pelvic binder and limb bandaging over a bolster.

    Science.gov (United States)

    Morris, Rhys; Loftus, Andrew; Friedmann, Yasmin; Parker, Paul; Pallister, Ian

    2017-04-01

    Unstable pelvic fractures can be life-threatening due to catastrophic haemorrhage. Non-invasive methods of reducing and stabilising these injuries include pelvic binder application and also lower limb bandaging over a knee-flexion bolster. Both of these methods help close the pelvic ring and should tamponade bleeding. This study aimed to quantify the intra-pelvic pressure changes that occurred with 3 different manoeuvres: lower limb bandaging over a bolster; a Trauma Pelvic Orthotic Device (T-POD) pelvic binder, and a combination of both. Following a pilot study with 2 soft embalmed cadavers, a formal study with 6 unembalmed cadavers was performed. For each specimen an unstable pelvic injury was created (OA/OTA 61-C1) by dividing the pelvic ring anteriorly and posteriorly. A 3-4cm manometric water-filled balloon was placed in the retropubic space and connected to a 50ml syringe and water manometer via a 3-way tap. A baseline pressure of 8cmH 2 O (equating to the average central venous pressure) was used for each cadaver. Steady intra-pelvic pressures (more reliably reflecting the pressures achieved following an intervention) were used in the subsequent statistical analysis, using R statistical language and Rstudio. Paired t-test or Wilcoxon's rank sum test were used (depending on the normality of the dataset) to determine the impact of each intervention on the intra-pelvic pressure. The mean steady intra-pelvic pressures were significantly greater than the baseline pressure for each intervention. The binder and limb bandaging over a bolster alone increased the mean steady pelvic pressures significantly to 24 (SE=5) (plower limb bandaging over a bolster and pelvic binder application significantly increased intra-pelvic pressure above the baseline pressure. This was further increased through combining these interventions, which could be useful clinically to augment haemorrhage control in these fractures. Lower-limb bandaging over a bolster, and pelvic binder

  5. Improving the Lives of Students, Gay and Straight Alike: Gay-Straight Alliances and the Role of School Psychologists

    Science.gov (United States)

    Murphy, Heather Elise

    2012-01-01

    Lesbian, gay, bisexual, and transgender (LGBT) students face many risk factors every day when they enter their school's door. These students often fear for their safety at school, are victimized, have academic difficulties, suffer from issues with their identity development, and are at risk for suicide. School-based Gay-Straight Alliances (GSAs)…

  6. In vitro and in vivo evaluation of microporous chitosan hydrogel/nanofibrin composite bandage for skin tissue regeneration.

    Science.gov (United States)

    Sudheesh Kumar, P T; Raj, N Mincy; Praveen, G; Chennazhi, Krishna Prasad; Nair, Shantikumar V; Jayakumar, R

    2013-02-01

    In this work, we have developed chitosan hydrogel/nanofibrin composite bandages (CFBs) and characterized using Fourier transform-infrared spectroscopy and scanning electron microscopy. The homogeneous distribution of nanofibrin in the prepared chitosan hydrogel matrix was confirmed by phosphotungstic acid-hematoxylin staining. The mechanical strength, swelling, biodegradation, porosity, whole-blood clotting, and platelet activation studies were carried out. In addition, the cell viability, cell attachment, and infiltration of the prepared CFBs were evaluated using human umbilical vein endothelial cells (HUVECs) and human dermal fibroblast (HDF) cells. It was found that the CFBs were microporous, flexible, biodegradable, and showed enhanced blood clotting and platelet activity compared to the one without nanofibrin. The prepared CFBs were capable of absorbing fluid and this was confirmed when immersed in phosphate buffered saline. Cell viability studies on HUVECs and HDF cells proved the nontoxic nature of the CFBs. Cell attachment and infiltration studies showed that the cells were found attached and proliferated on the CFBs. In vivo experiments were carried out in Sprague-Dawley rats and found that the wound healing occurred within 2 weeks when treated with CFBs than compared to the bare wound and wound treated with Kaltostat. The deposition of collagen was found to be more on CFB-treated wounds compared to the control. The above results proved the use of these CFBs as an ideal candidate for skin tissue regeneration and wound healing.

  7. Fatigue Life of High-Strength Steel Offshore Tubular Joints

    DEFF Research Database (Denmark)

    Petersen, Rasmus Ingomar; Agerskov, Henning; Lopez Martinez, Luis

    1996-01-01

    In the present investigation, the fatigue life of tubular joints in offshore steel structures is studied. Two test series on full-scale tubular joints have been carried through. One series was on joints in conventional offshore structural steel, and the other series was on joints in high-strength......In the present investigation, the fatigue life of tubular joints in offshore steel structures is studied. Two test series on full-scale tubular joints have been carried through. One series was on joints in conventional offshore structural steel, and the other series was on joints in high......-strength steel with a yield stress of 820-830 MPa and with high weldability and toughness properties. The test specimens of both series had the same geometry. The present report concentrates on the results obtained in the investigation on the high-strength steel tubular joints.The test specimens were fabricated...... from Ø 324-610 mm tubes, and the joints were loaded in in-plane bending. Both fatigue tests under constant amplitude loading and tests with a stochastic loading that is realistic in relation to offshore structures, are included in the investigation.A comparison between constant amplitude and variable...

  8. Mathematical rationalization for the renal tubular transport: revised concepts.

    Science.gov (United States)

    Mioni, Roberto; Marega, Alessandra; Romano, Giulio; Montanaro, Domenico

    2017-09-01

    The current emphasis on kinetics and in situ control of molecular exchanges, across the tubular membrane, has not been paralleled by corresponding improvements in our understanding of tubular behaviour at the macroscopic level of classical physiology. In this paper, we propose a mathematical rationalization of macroscopic tubular transport by means of a principal transport equation, originating from the law of mass action between substrate and carrier. The other equations, derived from the main one, demonstrate the possibility of distinguishing between transporters with low affinity and high capacity and transporters with high affinity and low capacity. Moreover, our model formalizes both tubular reabsorption and tubular secretion. Regarding the renal calcium handling, our model confirms the two-compartment system proposed by Mioni in 1971, with some important variants, which are in agreement with the fractional reabsorptions of this cation along the tubule, as verified by micro-puncture technique. To obtain the frequency distribution of saturated tubules, we have utilized the infinitesimal analysis method, starting from the equations proposed by Smith in 1943, concluding that all titration curves result from the combined effect of enzymatic approach and anatomical heterogeneity of the nephrons. The theoretical equations included in our manuscript reflect substantial and palpable physiological mechanisms able to suggest diagnosis and therapy of some electrolyte and hormonal disorders. At the end of this paper, we highlight advantages and disadvantages detectable by comparing our mathematical approach with Marshall's and Bijvoet's methods, proposed, respectively, in 1976 and 1984.

  9. Proximal tubular dysfunction as an indicator of chronic graft dysfunction

    Directory of Open Access Journals (Sweden)

    N.O.S. Câmara

    2009-03-01

    Full Text Available New strategies are being devised to limit the impact of renal sclerosis on graft function. Individualization of immunosuppression, specifically the interruption of calcineurin-inhibitors has been tried in order to promote better graft survival once chronic graft dysfunction has been established. However, the long-term impact of these approaches is still not totally clear. Nevertheless, patients at higher risk for tubular atrophy and interstitial fibrosis (TA/IF development should be carefully monitored for tubular function as well as glomerular performance. Since tubular-interstitial impairment is an early event in TA/IF pathogenesis and associated with graft function, it seems reasonable that strategies directed at assessing tubular structural integrity and function would yield important functional and prognostic data. The measurement of small proteins in urine such as α-1-microglobulin, N-acetyl-beta-D-glucosaminidase, alpha/pi S-glutathione transferases, β-2 microglobulin, and retinol binding protein is associated with proximal tubular cell dysfunction. Therefore, its straightforward assessment could provide a powerful tool in patient monitoring and ongoing clinical assessment of graft function, ultimately helping to facilitate longer patient and graft survival associated with good graft function.

  10. Kinking and Torsion Can Significantly Improve the Efficiency of Valveless Pumping in Periodically Compressed Tubular Conduits. Implications for Understanding of the Form-Function Relationship of Embryonic Heart Tubes

    Directory of Open Access Journals (Sweden)

    Florian Hiermeier

    2017-11-01

    Full Text Available Valveless pumping phenomena (peristalsis, Liebau-effect can generate unidirectional fluid flow in periodically compressed tubular conduits. Early embryonic hearts are tubular conduits acting as valveless pumps. It is unclear whether such hearts work as peristaltic or Liebau-effect pumps. During the initial phase of its pumping activity, the originally straight embryonic heart is subjected to deforming forces that produce bending, twisting, kinking, and coiling. This deformation process is called cardiac looping. Its function is traditionally seen as generating a configuration needed for establishment of correct alignments of pulmonary and systemic flow pathways in the mature heart of lung-breathing vertebrates. This idea conflicts with the fact that cardiac looping occurs in all vertebrates, including gill-breathing fishes. We speculate that looping morphogenesis may improve the efficiency of valveless pumping. To test the physical plausibility of this hypothesis, we analyzed the pumping performance of a Liebau-effect pump in straight and looped (kinked configurations. Compared to the straight configuration, the looped configuration significantly improved the pumping performance of our pump. This shows that looping can improve the efficiency of valveless pumping driven by the Liebau-effect. Further studies are needed to clarify whether this finding may have implications for understanding of the form-function relationship of embryonic hearts.

  11. Straight-Line Target Tracking for Unmanned Surface Vehicles

    Directory of Open Access Journals (Sweden)

    Morten Breivik

    2008-10-01

    Full Text Available This paper considers the subject of straight-line target tracking for unmanned surface vehicles (USVs. Target-tracking represents motion control scenarios where no information about the target behavior is known in advance, i.e., the path that the target traverses is not defined apriori. Specifically, this work presents the design of a motion control system which enables an underactuated USV to track a target that moves in a straight line at high speed. The motion control system employs a guidance principle originally developed for interceptor missiles, as well as a novel velocity controller inspired by maneuverability and agility concepts found in fighter aircraft literature. The performance of the suggested design is illustrated through full-scale USV experiments in the Trondheimsfjord.

  12. Three-Axis Ground Reaction Force Distribution during Straight Walking.

    Science.gov (United States)

    Hori, Masataka; Nakai, Akihito; Shimoyama, Isao

    2017-10-24

    We measured the three-axis ground reaction force (GRF) distribution during straight walking. Small three-axis force sensors composed of rubber and sensor chips were fabricated and calibrated. After sensor calibration, 16 force sensors were attached to the left shoe. The three-axis force distribution during straight walking was measured, and the local features of the three-axis force under the sole of the shoe were analyzed. The heel area played a role in receiving the braking force, the base area of the fourth and fifth toes applied little vertical or shear force, the base area of the second and third toes generated a portion of the propulsive force and received a large vertical force, and the base area of the big toe helped move the body's center of mass to the other foot. The results demonstrate that measuring the three-axis GRF distribution is useful for a detailed analysis of bipedal locomotion.

  13. Emergent patterns of collective cell migration under tubular confinement.

    Science.gov (United States)

    Xi, Wang; Sonam, Surabhi; Beng Saw, Thuan; Ladoux, Benoit; Teck Lim, Chwee

    2017-11-15

    Collective epithelial behaviors are essential for the development of lumens in organs. However, conventional assays of planar systems fail to replicate cell cohorts of tubular structures that advance in concerted ways on out-of-plane curved and confined surfaces, such as ductal elongation in vivo. Here, we mimic such coordinated tissue migration by forming lumens of epithelial cell sheets inside microtubes of 1-10 cell lengths in diameter. We show that these cell tubes reproduce the physiological apical-basal polarity, and have actin alignment, cell orientation, tissue organization, and migration modes that depend on the extent of tubular confinement and/or curvature. In contrast to flat constraint, the cell sheets in a highly constricted smaller microtube demonstrate slow motion with periodic relaxation, but fast overall movement in large microtubes. Altogether, our findings provide insights into the emerging migratory modes for epithelial migration and growth under tubular confinement, which are reminiscent of the in vivo scenario.

  14. Power generation characteristics of tubular type SOFC by wet process

    Energy Technology Data Exchange (ETDEWEB)

    Tajiri, H.; Nakayama, T. [Kyushu Electric Power Company, Inc., Fukuoka (Japan); Kuroishi, M. [TOTO Ltd., Kanagawa (Japan)] [and others

    1996-12-31

    The development of a practical solid oxide fuel cell requires improvement of a cell performance and a cell manufacturing technology suitable for the mass production. In particular tubular type SOFC is thought to be superior in its reliability because its configuration can avoid the high temperature sealing and reduce the thermal stress resulting from the contact between cells. The authors have fabricated a tubular cell with an air electrode support by a wet processing technique, which is suitable for mass production in improving a power density. To enhance the power output of the module, the Integrated Tubular-Type (ITT) cell has been developed. This paper reports the performance of the single cells with various active anode areas and the bundle with series-connected 9-ITT cells with an active anode area of 840 cm{sup 2}.

  15. Effect of corrosion on the buckling capacity of tubular members

    Science.gov (United States)

    Øyasæter, F. H.; Aeran, A.; Siriwardane, S. C.; Mikkelsen, O.

    2017-12-01

    Offshore installations are subjected to harsh marine environment and often have damages from corrosion. Several experimental and numerical studies were performed in the past to estimate buckling capacity of corroded tubular members. However, these studies were either based on limited experimental tests or numerical analyses of few cases resulting in semi-empirical relations. Also, there are no guidelines and recommendations in the currently available design standards. To fulfil this research gap, a new formula is proposed to estimate the residual strength of tubular members considering corrosion and initial geometrical imperfections. The proposed formula is verified with results from finite element analyses performed on several members and for varying corrosion patch parameters. The members are selected to represent the most relevant Eurocode buckling curve for tubular members. It is concluded that corrosion reduces the buckling capacity significantly and the proposed formula can be easily applied by practicing engineers without performing detailed numerical analyses.

  16. HER-2 amplification in tubular carcinoma of the breast.

    Science.gov (United States)

    Oakley, Gerard J; Tubbs, Raymond R; Crowe, Joseph; Sebek, Bruce; Budd, G Thomas; Patrick, Rebecca J; Procop, Gary W

    2006-07-01

    The prognostic and therapeutic implications of HER-2 gene amplification and estrogen and progesterone receptor status in breast cancer are well described. To address the relative paucity of information concerning HER-2 amplification for tubular carcinomas, we assessed the frequency of gene amplification in 55 tubular carcinomas of the breast from 54 patients, 5 of which had axillary node metastases. The HER-2 gene copy number was assessed by fluorescence in situ hybridization for the majority of tumors analyzed, whereas estrogen and progesterone receptor status was achieved by immunohistochemical analysis. HER-2 gene amplification was not observed in any of the tumors examined, and most were estrogen receptor-positive. This HER-2 gene amplification frequency was significantly lower than the frequency of gene amplification previously reported for all invasive ductal carcinoma of no special type (P < .01). HER-2 gene amplification likely occurs infrequently, or not at all, in tubular carcinomas of the breast, whereas most express estrogen receptors.

  17. MODELING OF TUBULAR ELECTROCHEMICAL REACTOR FOR DYE REMOVAL

    Directory of Open Access Journals (Sweden)

    V. VIJAYAKUMAR

    2017-06-01

    Full Text Available The aim of the present investigation is to model a tubular electrochemical reactor for the treatment of synthetic dye wastewater. The tubular reactor was modeled and solved by finite difference method. For the model solution, the column was divided into 11 nodes in the axial direction and the variation in the radial direction has been neglected. An initial dye concentration of 200 mg L-1was taken in the reservoir. The reactor was operated in a batch with recirculation operation. Based on preliminary experiments all parameters have been optimized. The model simulation is compared with the experimental value and it is observed that the model fairly matches well with the experiment. The modeling of tubular electrochemical reactors for dye waste water treatment could be useful in the design and scale up of electrochemical process.

  18. Penerapan Metode Straight Selection pada Sistem Parkir Universitas Bina Nusantara

    OpenAIRE

    Maharani, Mega; Merlina, Nita

    2014-01-01

    The parking information System is designed to develop the current system that has been employed at BINA NUSANTARA University. Currently, the parking system is limited only recording the police number and they are still manually looking for the available parking area. The system implements straight selection sorting data method, also known as the smallest number search method to determine the available parking location. Parking area will be automatically printed at parking ticket, thus the dri...

  19. Youth Empowerment and High School Gay-Straight Alliances

    OpenAIRE

    Russell, Stephen T.; Muraco, Anna; Subramaniam, Aarti; Laub, Carolyn

    2009-01-01

    In the field of positive youth development programs, “empowerment” is used interchangeably with youth activism, leadership, civic participation and self-efficacy. However, few studies have captured what empowerment means to young people in diverse contexts. This article explores how youth define and experience empowerment in youth-led organizations characterized by social justice goals: high school Gay-Straight Alliances (GSAs). Through focus group interviews, fifteen youth leaders of GSAs fr...

  20. Propagation of ovalization along straight pipes and elbows

    International Nuclear Information System (INIS)

    Millard, A.; Roche, R.L.

    1981-01-01

    The aim of this paper is to present analytical solutions for the propagation of evalization and the variation of the flexibility factor along pipe bends terminated by straight pipes or flanges, under in-plane bending, assuming an elastic material behaviour. The influence of the various strains in analysed in the simple case of a straight pipe, subjected to an elliptical cross-section shape deformation at one end. The results enlighten the very important part played by the distorsion in the propagation. They have been compared with finite elements solutions and with simple experiments. The solution is developed for an elbow terminated by a straight pipe or a flange, following the Von Karman's approach: local displacements are expanded in Fourier series, the coefficients of which vary along the curvilinear abscissa, like the rotation of the cross-section as a whole; the differential equations as well as the boundary conditions are found by minimization of the total potential energy of the assembly. The solutions are compared to existing and experimental results. (orig./HP)

  1. 49 CFR Appendix A to Part 1035 - Uniform Straight Bill of Lading

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 8 2010-10-01 2010-10-01 false Uniform Straight Bill of Lading A Appendix A to Part 1035 Transportation Other Regulations Relating to Transportation (Continued) SURFACE... Appendix A to Part 1035—Uniform Straight Bill of Lading Uniform Straight Bill of Lading Original—Not...

  2. 26 CFR 1.9001 - Statutory provisions; Retirement-Straight Line Adjustment Act of 1958.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 13 2010-04-01 2010-04-01 false Statutory provisions; Retirement-Straight Line... provisions; Retirement-Straight Line Adjustment Act of 1958. Section 94 of the Technical Amendments Act of 1958 (72 Stat. 1669) provides as follows: Sec. 94. Change from retirement to straight line method of...

  3. 21 CFR 70.20 - Packaging requirements for straight colors (other than hair dyes).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Packaging requirements for straight colors (other than hair dyes). 70.20 Section 70.20 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH... straight colors (other than hair dyes). Straight colors shall be packaged in containers which prevent...

  4. 26 CFR 7.57(d)-1 - Election with respect to straight line recovery of intangibles.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 14 2010-04-01 2010-04-01 false Election with respect to straight line recovery... ACT OF 1976 § 7.57(d)-1 Election with respect to straight line recovery of intangibles. (a) Purpose... Tax Reform Act of 1976. Under this election taxpayers may use cost depletion to compute straight line...

  5. Comparison of bandage contact lens removal on the fourth versus seventh postoperative day after photorefractive keratectomy: A randomized clinical trial.

    Science.gov (United States)

    Mohammadpour, Mehrdad; Shakoor, Delaram; Hashemi, Hassan; Aghaie Meybodi, Mohamad; Rajabi, Fateme; Hosseini, Pegah

    2017-06-01

    To compare the outcomes of bandage contact lens (BCL) removal on the fourth versus seventh post-operative day following photorefractive keratectomy (PRK). This study recruited eyes of patients who underwent PRK surgery. The patients were randomly assigned to 2 groups. In Group 1 BCL was removed on the 4th postoperative day, while in Group 2, BCL was removed on the 7th postoperative day. After BCL removal, patients were asked to express their pain score and eye discomfort. At one and three months follow-up examinations, visual acuity scale was assessed. Slit-lamp examination was performed in all visits to evaluate complications. 260 eyes of 130 patients underwent PRK. The age and sex ratio were not significantly different between the two groups. One month after the surgery, the logMAR uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were significantly lower in Group 2 (P value = 0.016, 0.001 respectively), however, the UDVA and CDVA were not significantly different after 3 months (P > 0.05). In Group 1, filamentary keratitis (FK) was observed in 10 (7.6%) eyes, 6 (4.61%) eyes were diagnosed with recurrent corneal erosion (RCE) and corneal haze was detected in 3 (2.3%) eyes. However, in Group 2, RCE was observed in 4 (2.3%) and FK was noted in 4 (3.07%) eyes. No haze was seen in Group 2. The difference in rate of complications was statistically significant (14.6% and 6.1% in Groups 1 and 2, respectively, P = 0.02). Pain and eye discomfort scores were not significantly different (P > 0.05). There was no major complications including infectious keratitis in either groups. Following PRK surgery, BCL removal on the seventh postoperative day yields faster visual rehabilitation and lower rate of postoperative complications with no increase in eye pain, discomfort or infection.

  6. Evaluation of Two Miniplate Systems and Figure-of-eight Bandages for Stabilization of Experimentally Induced Ulnar and Radial Fractures in Pigeons ( Columba livia ).

    Science.gov (United States)

    Bennert, Beatrice M; Kircher, Patrick R; Gutbrod, Andreas; Riechert, Juliane; Hatt, Jean-Michel

    2016-06-01

    Although plate fixation has advantages over other fixation methods for certain indications, it is rarely used in avian surgery, especially in birds that weigh less than 1000 g. Exceptionally small plating systems for these birds are required, which are relatively expensive and difficult to insert. To study avian fracture healing after repair using miniplates, we evaluated 2 steel miniplate systems in 27 pigeons ( Columba livia ) divided into 4 groups. In each pigeon, the left ulna and radius were transected and the ulna was repaired with a bone plate. In groups A and B, a 1.3-mm adaption plate was applied without and with a figure-of-eight bandage; in groups C and D, a 1.0-mm compression plate was applied without and with a bandage, respectively. Healing was evaluated with radiographs after 3, 14, and 28 days; flight tests were conducted after 14, 21, and 28 days; and the wing was macroscopically examined after euthanasia of birds on day 28. Fractures healed without bending or distortion of the plate in all 27 birds, and no significant differences in healing were found between treatment groups. At the end of the study, 23 pigeons (85.2%) showed good or very good flight ability. Results show the 1.3-mm adaption plate and the 1.0-mm compression plate meet the requirements for avian osteosynthesis and can be recommended for fracture repair of the ulna or other long bones in birds weighing less than 500 g. The application of a figure-of-eight bandage might be beneficial in fracture healing.

  7. The Use of the D-STAT Dry Bandage for the Control of Vascular Access Site Bleeding: A Multicenter Experience in 376 Patients

    International Nuclear Information System (INIS)

    Hallak, Omar K.; Cubeddu, Roberto J.; Griffith, Rose A.; Reyes, Bernardo J.

    2007-01-01

    Multiple topical hemostats have been approved for control of surface bleeding from vascular access sites. The majority of these devices, however, have few clinical data supporting their use. This study was conducted to assess the efficacy and safety of the new commercially available D-Stat Dry hemostatic bandage compared to standard care manual compression. A prospective, randomized, multicenter trial was conducted in patients undergoing diagnostic cardiac catheterization or peripheral angiography utilizing femoral artery access. Subjects were randomized to either the D-Stat Dry bandage as an adjunct to manual compression or manual compression alone. Primary end points were time-to-hemostasis (TTH) and major complications. Secondary end points included minor complications, patient satisfaction, time-to-ambulation (TTA), and time-to-discharge (TTD). Three hundred seventy-six subjects (189 control, 187 investigational) with similar baseline characteristics participated in the study. The mean age was 61.5 years, with a male predominance of 58%. TTH was significantly lower in the investigational group (7.8 vs. 13.0 min; p = 0.001). No difference in major complication rates was observed between the groups. The mean TTA (investigational, 392 min, vs. control, 415 min; p = 0.023) and patient satisfaction significantly favored the investigational group (p = 0.025). No difference in TTD or the rate of minor complications was observed. This study demonstrates that in the aforementioned population, the D-Stat Dry bandage is safe and effective in reducing both TTH and TTA and results in improved patient satisfaction

  8. Cultivation of micro-algae in closed tubular reactor

    Energy Technology Data Exchange (ETDEWEB)

    Gudin, C.; Bernard, A.; Chaumont, D.

    1983-11-01

    A description is presented of the three culture pilot utilities in activity under natural light, including glass tubular solar collector (30 mm diameter) in which the microalgae culture circulates. The utility is controled automatically (thermal regulation, gaseous transfers, continuous culture organization). The tests were conducted for the production of polysaccharides (Porphyridium cruentum, chlamydomonas mexicana) or hydrocarbons (Botriococcus braunii).

  9. Modeling of heat transfer in wall-cooled tubular reactors

    NARCIS (Netherlands)

    Koning, G.W.; Westerterp, K.R.

    1999-01-01

    In a pilot scale wall-cooled tubular reactor, temperature profiles have been measured with and without reaction. As a model reaction oxidation of carbon monoxide in air over a copper chromite catalyst has been used. The kinetics of this reaction have been determined separately in two kinetic

  10. The H^{-1}-norm of tubular neighbourhoods of curves

    NARCIS (Netherlands)

    Gennip, van Y.; Peletier, M.A.

    2011-01-01

    We study the H^{-1}-norm of the function 1 on tubular neighbourhoods of curves in R^2. We take the limit of small thickness epsilon, and we prove two different asymptotic results. The first is an asymptotic development for a fixed curve in the limit epsilon to 0, containing contributions from the

  11. Hemodynamic and tubular changes induced by contrast media.

    Science.gov (United States)

    Caiazza, Antonella; Russo, Luigi; Sabbatini, Massimo; Russo, Domenico

    2014-01-01

    The incidence of acute kidney injury induced by contrast media (CI-AKI) is the third cause of AKI in hospitalized patients. Contrast media cause relevant alterations both in renal hemodynamics and in renal tubular cell function that lead to CI-AKI. The vasoconstriction of intrarenal vasculature is the main hemodynamic change induced by contrast media; the vasoconstriction is accompanied by a cascade of events leading to ischemia and reduction of glomerular filtration rate. Cytotoxicity of contrast media causes apoptosis of tubular cells with consequent formation of casts and worsening of ischemia. There is an interplay between the negative effects of contrast media on renal hemodynamics and on tubular cell function that leads to activation of renin-angiotensin system and increased production of reactive oxygen species (ROS) within the kidney. Production of ROS intensifies cellular hypoxia through endothelial dysfunction and alteration of mechanisms regulating tubular cells transport. The physiochemical characteristics of contrast media play a critical role in the incidence of CI-AKI. Guidelines suggest the use of either isoosmolar or low-osmolar contrast media rather than high-osmolar contrast media particularly in patients at increased risk of CI-AKI. Older age, presence of atherosclerosis, congestive heart failure, chronic renal disease, nephrotoxic drugs, and diuretics may multiply the risk of CI-AKI.

  12. Elevated oxidized glutathione in cystinotic proximal tubular epithelial cells.

    Science.gov (United States)

    Wilmer, Martijn J G; de Graaf-Hess, Adriana; Blom, Henk J; Dijkman, Henry B P M; Monnens, Leo A; van den Heuvel, Lambertus P; Levtchenko, Elena N

    2005-11-18

    Cystinosis, the most frequent cause of inborn Fanconi syndrome, is characterized by the lysosomal cystine accumulation, caused by mutations in the CTNS gene. To elucidate the pathogenesis of cystinosis, we cultured proximal tubular cells from urine of cystinotic patients (n = 9) and healthy controls (n = 9), followed by immortalization with human papilloma virus (HPV E6/E7). Obtained cell lines displayed basolateral polarization, alkaline phosphatase activity, and presence of aminopeptidase N (CD-13) and megalin, confirming their proximal tubular origin. Cystinotic cell lines exhibited elevated cystine levels (0.86 +/- 0.95 nmol/mg versus 0.09 +/- 0.01 nmol/mg protein in controls, p = 0.03). Oxidized glutathione was elevated in cystinotic cells (1.16 +/- 0.83 nmol/mg versus 0.29 +/- 0.18 nmol/mg protein, p = 0.04), while total glutathione, free cysteine, and ATP contents were normal in these cells. In conclusion, elevated oxidized glutathione in cystinotic proximal tubular epithelial cell lines suggests increased oxidative stress, which may contribute to tubular dysfunction in cystinosis.

  13. Tubularized incised plate technique for recurrent hypospadias: a ...

    African Journals Online (AJOL)

    management of recurrent hypospadias. Summary background ... The potential advantages of tubularized incised plate .... after a mean duration of 4.9 ± 3.1 years from the previous repair (Table 2). .... erection and the risk of infection, especially in patients older than 15 .... However, previous surgery often limits the availability ...

  14. Modeling of Unidirectional-Overloaded Transition in Catalytic Tubular Microjets

    NARCIS (Netherlands)

    Klingner, Anke; Khalil, Islam S. M.; Magdanz, Veronika; Fomin, Vladimir M.; Schmidt, Oliver G.; Misra, Sarthak

    2017-01-01

    A numerical time-resolved model is presented for predicting the transition between unidirectional and overloaded motion of catalytic tubular microjets (Ti/Fe/Pt rolled-up microtubes) in an aqueous solution of hydrogen peroxide. Unidirectional movement is achieved by periodic ejection of gas bubbles

  15. Characterization of Foam Catalysts as Packing for Tubular Reactors.

    Czech Academy of Sciences Publication Activity Database

    Lali, Farzad

    2016-01-01

    Roč. 105, JUL 2016 (2016), s. 1-9 ISSN 0255-2701 Institutional support: RVO:67985858 Keywords : overall mass transfer * foam catalyst * tubular reactor Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 2.234, year: 2016

  16. Importance of early audiologic assessment in distal renal tubular acidosis

    Directory of Open Access Journals (Sweden)

    Elizabeth Norgett

    2010-12-01

    Full Text Available Anand P Swayamprakasam1, Elizabeth Stover1, Elizabeth Norgett1, Katherine G Blake-Palmer1, Michael J Cunningham2, Fiona E Karet11Department of Medical Genetics, Cambridge Institute for Medical Research, Cambridge, UK; 2Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, Boston, MA, USAAbstract: Autosomal recessive distal renal tubular acidosis is usually a severe disease of childhood, often presenting as failure to thrive in infancy. It is often, but not always, accompanied by sensorineural hearing loss, the clinical severity and age of onset of which may be different from the other clinical features. Mutations in either ATP6V1B1 or ATP6V0A4 are the chief causes of primary distal renal tubular acidosis with or without hearing loss, although the loss is often milder in the latter. We describe a kindred with compound heterozygous alterations in ATP6V0A4, where hearing loss was formally diagnosed late in both siblings such that they missed early opportunities for hearing support. This kindred highlights the importance of routine audiologic assessments of all children with distal renal tubular acidosis, irrespective either of age at diagnosis or of which gene is mutated. In addition, when diagnostic genetic testing is undertaken, both genes should be screened irrespective of current hearing status. A strategy for this is outlined.Keywords: sensorineural hearing loss, renal tubular acidosis, recessive, genetics, mutation

  17. Finite element analysis of tubular joints in offshore structures ...

    African Journals Online (AJOL)

    ... representing a 2-D model of the joint between the brace and the chord walls. This was subsequently followed but finite element analysis of six tubular joints. A global analysis was initially undertaken, then the submodel analysis carried in the areas of stress concentration. Journal of Civil Engineering, JKUAT (2001) Vol 6, ...

  18. New methods for the geometrical analysis of tubular organs.

    Science.gov (United States)

    Grélard, Florent; Baldacci, Fabien; Vialard, Anne; Domenger, Jean-Philippe

    2017-12-01

    This paper presents new methods to study the shape of tubular organs. Determining precise cross-sections is of major importance to perform geometrical measurements, such as diameter, wall-thickness estimation or area measurement. Our first contribution is a robust method to estimate orthogonal planes based on the Voronoi Covariance Measure. Our method is not relying on a curve-skeleton computation beforehand. This means our orthogonal plane estimator can be used either on the skeleton or on the volume. Another important step towards tubular organ characterization is achieved through curve-skeletonization, as skeletons allow to compare two tubular organs, and to perform virtual endoscopy. Our second contribution is dedicated to correcting common defects of the skeleton by new pruning and recentering methods. Finally, we propose a new method for curve-skeleton extraction. Various results are shown on different types of segmented tubular organs, such as neurons, airway-tree and blood vessels. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Expansion of Tubular with Elastomers in Multilateral Wells

    Directory of Open Access Journals (Sweden)

    Md Velden

    2013-06-01

    Full Text Available The use of solid expandable tubular technology during the last decade has focused on solving many challenges in well drilling and delivery including zonal isolation, deep drilling, conservation of hole sizes, etc. not only as pioneered solution but also providing cost effective and long lasting solutions. Concurrently, the technology was extended for construction of multilateral in typical wells. The process of horizontal tubular expansion is similar to the vertical expansion of expandable tubular in down-hole environment with the addition of uniformly distributed force due to its weight. The expansion is targeted to increase its diameter such that post expansion characteristics remain within allowable limits. In this study a typical expandable tubular of 57.15 mm outer diameter and 6.35 mm wall thickness was used with two different elastomer seals of 5 and 7 mm thickness placed at equal spacing of 200 mm. The developed stress contours during expansion process clearly showed the high stress areas in the vicinity of expansion region which lies around the mandrel. These high stresses may result in excessive wear of the mandrel. It was also found out that the drawing force increases as the mandrel angle, expansion ratio, and friction coefficient increases. A mandrel angle of 20o  requires minimum expansion force and can be considered as an optimum geometrical parameter to lower the power required for expansion.

  20. Transient acute tubular dysfunction in the newborn: CT findings

    International Nuclear Information System (INIS)

    McLaughlin, M.G.; Schwartz, J.R.; Swayne, L.C.; Columbia Univ., New York; Rubenstein, J.B.; University of Medicine and Dentistry of New Jersey, Newark, NJ; Block, D.C.

    1990-01-01

    We report the CT and sonographic findings of transient acute tubular disease in a newborn infant, who was dehydrated at birth. The initial CT scan demonstrated focal areas of increased attenuation within the central portions of both kidneys, and sonography showed echogenic medullary pyramids. After adequate hydration, a follow-up examination demonstrated complete spontaneous resolution. (orig.)

  1. Renal pathophysiologic role of cortical tubular inclusion bodies.

    Science.gov (United States)

    Radi, Zaher A; Stewart, Zachary S; Grzemski, Felicity A; Bobrowski, Walter F

    2013-01-01

    Renal tubular inclusion bodies are rarely associated with drug administration. The authors describe the finding of renal cortical tubular intranuclear and intracytoplasmic inclusion bodies associated with the oral administration of a norepinephrine/serotonin reuptake inhibitor (NSRI) test article in Sprague-Dawley (SD) rats. Rats were given an NSRI daily for 4 weeks, and kidney histopathologic, ultrastructural pathology, and immunohistochemical examinations were performed. Round eosinophilic intranuclear inclusion bodies were observed histologically in the tubular epithelial cells of the renal cortex in male and female SD rats given the NSRI compound. No evidence of degeneration or necrosis was noted in the inclusion-containing renal cells. By ultrastructural pathology, inclusion bodies consisted of finely granular, amorphous, and uniformly stained nonmembrane-bound material. By immunohistochemistry, inclusion bodies stained positive for d-amino acid oxidase (DAO) protein. In addition, similar inclusion bodies were noted in the cytoplasmic tubular epithelial compartment by ultrastructural and immunohistochemical examination.  This is the first description of these renal inclusion bodies after an NSRI test article administration in SD rats. Such drug-induced renal inclusion bodies are rat-specific, do not represent an expression of nephrotoxicity, represent altered metabolism of d-amino acids, and are not relevant to human safety risk assessment.

  2. Urinary Markers of Tubular Injury in Early Diabetic Nephropathy

    Directory of Open Access Journals (Sweden)

    Temesgen Fiseha

    2016-01-01

    Full Text Available Diabetic nephropathy (DN is a common and serious complication of diabetes associated with adverse outcomes of renal failure, cardiovascular disease, and premature mortality. Early and accurate identification of DN is therefore of critical importance to improve patient outcomes. Albuminuria, a marker of glomerular involvement in early renal damage, cannot always detect early DN. Thus, more sensitive and specific markers in addition to albuminuria are needed to predict the early onset and progression of DN. Tubular injury, as shown by the detection of tubular injury markers in the urine, is a critical component of the early course of DN. These urinary tubular markers may increase in diabetic patients, even before diagnosis of microalbuminuria representing early markers of normoalbuminuric DN. In this review we summarized some new and important urinary markers of tubular injury, such as neutrophil gelatinase associated lipocalin (NGAL, kidney injury molecule-1 (KIM-1, liver-type fatty acid binding protein (L-FABP, N-acetyl-beta-glucosaminidase (NAG, alpha-1 microglobulin (A1M, beta 2-microglobulin (B2-M, and retinol binding protein (RBP associated with early DN.

  3. Some asymptotic properties of functions holomorphic in tubular domains

    International Nuclear Information System (INIS)

    Zavialov, B.I.

    1988-10-01

    For the function holomorphic in curved tubular domain the connection between asymptotic behaviour of real part of its boundary value at a given point of base manifold and asymptotic behaviour of the whole function from the inside of this domain is studied. (author). 3 refs

  4. Torsional stresses in the transverse fillet weld tubular joints

    NARCIS (Netherlands)

    Gunay, D.; Aydemir, A.; Özer, H.

    1996-01-01

    Torsional stresses, 'tre and tel , in tbe transverse fillet tubular weld joint subjected to torsional load have been analyzed by the finite element method using triangular and quadrilateral izoparametric axisymmetric fourier type torus finite elements. There is an axisymmetry with respect to

  5. Experiments in MARIUS on HTR tubular fuel with loose particles

    Energy Technology Data Exchange (ETDEWEB)

    Bosser, R; Langlet, G

    1972-06-15

    The work described on HTR tubular fuel with loose particles is the first part of a program in three points. The cell is the same in the three experiments, only particles in the fuel container are changed. The aim of the experiment is to achieve the buckling in a critical facility. A description of the techniques of measurements, calculations, and results are presented.

  6. Nerve regeneration using tubular scaffolds from biodegradable polyurethane.

    Science.gov (United States)

    Hausner, T; Schmidhammer, R; Zandieh, S; Hopf, R; Schultz, A; Gogolewski, S; Hertz, H; Redl, H

    2007-01-01

    In severe nerve lesion, nerve defects and in brachial plexus reconstruction, autologous nerve grafting is the golden standard. Although, nerve grafting technique is the best available approach a major disadvantages exists: there is a limited source of autologous nerve grafts. This study presents data on the use of tubular scaffolds with uniaxial pore orientation from experimental biodegradable polyurethanes coated with fibrin sealant to regenerate a 8 mm resected segment of rat sciatic nerve. Tubular scaffolds: prepared by extrusion of the polymer solution in DMF into water coagulation bath. The polymer used for the preparation of tubular scaffolds was a biodegradable polyurethane based on hexamethylene diisocyanate, poly(epsilon-caprolactone) and dianhydro-D-sorbitol. EXPERIMENTAL MODEL: Eighteen Sprague Dawley rats underwent mid-thigh sciatic nerve transection and were randomly assigned to two experimental groups with immediate repair: (1) tubular scaffold, (2) 180 degrees rotated sciatic nerve segment (control). Serial functional measurements (toe spread test, placing tests) were performed weekly from 3rd to 12th week after nerve repair. On week 12, electrophysiological assessment was performed. Sciatic nerve and scaffold/nerve grafts were harvested for histomorphometric analysis. Collagenic connective tissue, Schwann cells and axons were evaluated in the proximal nerve stump, the scaffold/nerve graft and the distal nerve stump. The implants have uniaxially-oriented pore structure with a pore size in the range of 2 micorm (the pore wall) and 75 x 700 microm (elongated pores in the implant lumen). The skin of the tubular implants was nonporous. Animals which underwent repair with tubular scaffolds of biodegradable polyurethanes coated with diluted fibrin sealant had no significant functional differences compared with the nerve graft group. Control group resulted in a trend-wise better electrophysiological recovery but did not show statistically significant

  7. Factor H and Properdin Recognize Different Epitopes on Renal Tubular Epithelial Heparan Sulfate

    NARCIS (Netherlands)

    Zaferani, Azadeh; Vives, Romain R.; van der Pol, Pieter; Navis, Gerjan J.; Daha, Mohamed R.; van Kooten, Cees; Lortat-Jacob, Hugues; Seelen, Marc A.; van den Born, Jacob

    2012-01-01

    During proteinuria, renal tubular epithelial cells become exposed to ultrafiltrate-derived serum proteins, including complement factors. Recently, we showed that properdin binds to tubular heparan sulfates (HS). We now document that factor H also binds to tubular HS, although to a different epitope

  8. The Theory and Assessment of Spatial Straightness Error Matched New Generation GPS

    International Nuclear Information System (INIS)

    Zhang, X B; Sheng, X L; Jiang, X Q; Li, Z

    2006-01-01

    In order to assess spatial straightness error matched new generation Dimensional Geometrical Product Specification and Verification (GPS), the theory of spatial straightness error assessing is proposed and its advantages are analyzed based on metrology and statistics in this paper. Then, the assessing parameter system is proposed and it is testified in real application comparing to assessment result of the geometric tolerance theory. Statistical parameters of this assessing system post the different characteristics of spatial straightness error, and can reveal the impact of spatial straightness error on the accessory function more roundly to complement the single assessing parameter of geometrical tolerance for straightness error. The statistical spatial straightness tolerance and statistical spatial straightness error proposed in this paper is possible to be applied in evaluation of other error of form, orientation, location and run-out

  9. 99mTc renal tubular function agents: Current status

    International Nuclear Information System (INIS)

    Eshima, D.; Fritzberg, A.R.; Taylor, A. Jr.

    1990-01-01

    Orthoiodohippuric (OIH) acid labeled with 131I is a widely used renal radiopharmaceutical agent and has been the standard radiopharmaceutical agent for the measurement of effective renal plasma flow (EPRF). Limitations to the routine clinical use of 131I OIH are related to the suboptimal imaging properties of the 131I radionuclide and its relatively high radiation dose. 123I has been substituted for 131I; however, its high cost and short shelf-life have limited its widespread use. Recent work has centered on the development of a new 99mTc renal tubular function agent, which would use the optimal radionuclidic properties and availability of 99mTc and combine the clinical information provided by OIH. The search for a suitable 99mTc renal tubular function agent has focused on the diamide dithiolate (N2S2), the paraaminohippuric iminodiacetic acid (PAHIDA), and the triamide mercaptide (N3S) donor ligand systems. To date, the most promising 99mTc tubular function agent is the N3S complex: 99mTc mercaptoacetyltriglycine (99mTc MAG3). Studies in animal models in diuresis, dehydration, acid or base imbalance, ischemia, and renal artery stenosis demonstrate that 99mTc MAG3 behaves similarly to 131I OIH. A simple kit formulation is available that yields the 99mTc MAG3 complex in high radiochemical purity. Studies in normal subjects and patients indicate that 99mTc MAG3 is an excellent 99mTc renal tubular agent, but its plasma clearance is only 50% to 60% that of OIH. In an effort to develop an improved 99mTc renal tubular function agent, changes have been made in the core N3S donor ligand system, but to date no agent has been synthesized that is clinically superior to 99mTc MAG3. 61 references

  10. Straight spinning cosmic strings in Brans-Dicke gravity

    Science.gov (United States)

    Dos Santos, S. Mittmann; da Silva, J. M. Hoff; Cindra, J. L.

    2018-03-01

    An exact solution of straight spinning cosmic strings in Brans-Dicke theory of gravitation is presented. The possibility of the existence of closed time-like curves around these cosmic strings is analyzed. Furthermore, the stability about the formation of the topological defect discussed here is checked. It is shown that the existence of a suitable choice for the integration constants in which closed time-like curves are not allowed. We also study the (im)possibility of using the obtained spacetime in the rotational curves problem.

  11. The DFBX cryogenic distribution boxes for the LHC straight sections

    International Nuclear Information System (INIS)

    Zbasnik, Jon P.; Corradi, Carol A.; Green, Michael A.; Kajiyama, Y.; Knolls, Michael J.; LaMantia, Roberto F.; Rasson, Joseph E.; Reavill, Dulie; Turner, William C.

    2002-01-01

    The DFBX distribution boxes are designed to connect the LHC cryogenic distribution system to the interaction region quadrupoles [1] and dipoles for the Large Hadron Collider (LHC). The DFBX distribution boxes also have the current leads for the superconducting interaction region magnets and the LHC interaction region correction coils. The DFBX boxes also connect the magnet and cryogenic instrumentation to the CERN data collection system. The DFBX boxes serve as the cryogenic circulation center and the nerve center for four of the LHC straight sections. This report describes primarily the cryogenic function of the DFBXs

  12. Gamma-ray streaming in straight pipes and bent ducts

    International Nuclear Information System (INIS)

    Eid, M.; Diop, C.M.; Nimal, J.C.

    1985-04-01

    An important shielding problem is the gamma-ray streaming through voids. These problems are encountered in the reactors and reprocessing plants. A Monte Carlo method has been choosed as one of the most powerful technics to solve this kind of problems. Here in that frame, a biasing system which is adapted for two types of geometries is proposed: straight pipes and bent ducts. A code has been written applying this technique. The numerical results obained show the efficiency and the very good economy of the method proposed. It is hoped to extend the method to deal with more complex geometries and polykinetic situation as well

  13. Evaluating the Subjective Straight Ahead Before and After Spaceflight

    Science.gov (United States)

    Campbell, D. J.; Wood, S. J.; Reschke, M. F.; Clement, G.

    2017-01-01

    This joint European Space Agency (ESA) - NASA study will address adaptive changes in spatial orientation related to the subjective straight ahead and the use of a vibrotactile sensory aid to reduce perceptual errors. The study will be conducted before and after long duration expeditions to the International Space Station (ISS) to examine how spatial processing of target location is altered following exposure to microgravity. This study addresses the sensorimotor research gap to "determine the changes in sensorimotor function over the course of a mission and during recovery after landing."

  14. Secondary Flow Phenomena in Rotating Radial Straight Pipes

    OpenAIRE

    Cheng, K. C.; Wang, Liqiu

    1995-01-01

    Flow visualization results for secondary flow phenomena near the exit of a rotating radial-axis straight pipe (length ࡁ = 82 cm, inside diameter d = 3.81 cm, ࡁ/d 21.52) are presented to study the stabilizing (relaminarization) and destabilizing (early transition from laminar to turbulent flow) effects of Coriolis forces for Reynolds numbers Re = 500 ∼ 4,500 and rotating speeds n = 0 ∼ 200 rpm. The flow visualization was realised by smoke injection method. The main features of the trans...

  15. Safeguards and security benefits of project straight-line

    International Nuclear Information System (INIS)

    Jaeger, C.D.; Waddoups, I.G.

    1995-01-01

    As a result of a number of events the inventory of fissile materials no longer in nuclear weapons in the United States is increasing. This has led to a growing concern regarding the potential for theft and/or diversion and accountability of this material. Straight-Line is a project whose purpose is to demonstrate a site-independent system to monitor stored nuclear material (e.g. plutonium) and integrate the collection, processing and dissemination of information regarding this material. Safeguards and security (S ampersand S) goals of this project include data transfer of information on nuclear material to appropriate users to enhance S ampersand S, continuous on-line accountability, reduction of hands-on access to nuclear materials, incorporation of information security technologies, and early detection of tampering or unauthorized material movement. This paper addresses threat considerations, S ampersand S requirements, S ampersand S objectives, and issues for the Straight-Line project. S ampersand S features and benefits of this project are discussed with respect to existing item monitoring systems and/or other material tracking systems being developed

  16. Excessive deformation and failure of straight parts and elbows

    International Nuclear Information System (INIS)

    Touboul, F.; Acker, D.

    1991-01-01

    The design rules for LMFBRs must cover the ranges of loading types and geometries wider than PWR Design Codes. Steam pipework does not differ between two reactor systems, but as far as sodium piping is concerned, usual PWR criteria may not be adequate. The LMFBR sodium piping is operated at high temperature and low pressure level. Moreover, these peculiar loadings require the geometrical characteristics completely different in the fact that the piping must be flexible but need not to be thick. For such piping components, the ultimate behavior depends much on the geometry. 170 experimental results on straight parts and 95 results on elbows were investigated. As for elbows, half of the tests were performed under in-plane closing moment. On the analysis of straight pipes and elbows, the experiments and the proposed expressions for the evaluation of collapse and instability moments are described, respectively. The application of the present study to the design rules and the criteria for various loading conditions are reported. It is difficult to experimentally distinguish between plastic instability and buckling. (K.I.)

  17. An in-situ measuring method for planar straightness error

    Science.gov (United States)

    Chen, Xi; Fu, Luhua; Yang, Tongyu; Sun, Changku; Wang, Zhong; Zhao, Yan; Liu, Changjie

    2018-01-01

    According to some current problems in the course of measuring the plane shape error of workpiece, an in-situ measuring method based on laser triangulation is presented in this paper. The method avoids the inefficiency of traditional methods like knife straightedge as well as the time and cost requirements of coordinate measuring machine(CMM). A laser-based measuring head is designed and installed on the spindle of a numerical control(NC) machine. The measuring head moves in the path planning to measure measuring points. The spatial coordinates of the measuring points are obtained by the combination of the laser triangulation displacement sensor and the coordinate system of the NC machine, which could make the indicators of measurement come true. The method to evaluate planar straightness error adopts particle swarm optimization(PSO). To verify the feasibility and accuracy of the measuring method, simulation experiments were implemented with a CMM. Comparing the measurement results of measuring head with the corresponding measured values obtained by composite measuring machine, it is verified that the method can realize high-precise and automatic measurement of the planar straightness error of the workpiece.

  18. Performance improvement in a tubular heat exchanger by punched delta-winglet vortex generators

    Science.gov (United States)

    Khanoknaiyakarn, C.; Promvonge, P.; Thianpong, C.; Skullong, S.

    2018-01-01

    A novel tubular heat exchanger incorporated with punched delta-winglet vortex generators (called perforated delta-winglet vortex generator, P-DWVG) is proposed for improving its thermal performance and energy saving. The P-DWVG elements are punched out from a straight tape having its width nearly equal to the tube diameter before insertion. The main aim at employing the P-DWVG insert is to produce counter-rotating vortices along the tube to promote turbulence intensity inside as well as to transport the cold fluid at the central core to the near-wall regions. The experiment was performed to study thermal behaviors in a uniform heat-fluxed tube inserted with P-DWVGs. The P-DWVGs with the attack angle of 45° were mounted periodically with three different blockage ratios (BR = 0.1, 0.2 and 0.3) and two pitch ratios (PR = 2 and 3). Air as the test fluid was varied to obtain turbulent airflow for Reynolds number (Re) in a range of 4,150-25,500. The experimental results show that the P-DWVG provides a considerable increase in the rate of heat transfer around 3.1-4.01 times whereas friction factor increases around 11.44- 34.23 times higher than the plain tube. To assess the real benefits of P-DWVGs, thermal performance factor (TEF) is examined and in the range of 1.39-1.48 where its maximum is at BR = 0.1 and PR = 2.

  19. Evacuated, displacement compression mold. [of tubular bodies from thermosetting plastics

    Science.gov (United States)

    Heier, W. C. (Inventor)

    1974-01-01

    A process of molding long thin-wall tubular bodies from thermosetting plastic molding compounds is described wherein the tubular body lengths may be several times the diameters. The process is accomplished by loading a predetermined quantity of molding compound into a female mold cavity closed at one end by a force mandrel. After closing the other end of the female mold with a balance mandrel, the loaded cavity is evacuated by applying a vacuum of from one-to-five mm pressure for a period of fifteen-to-thirty minutes. The mold temperature is raised to the minimum temperature at which the resin constituent of the compound will soften or plasticize and a pressure of 2500 psi is applied.

  20. Luminous effectiveness of tubular light-guides in tropics

    Energy Technology Data Exchange (ETDEWEB)

    Darula, Stanislav; Kittler, Richard; Kocifaj, Miroslav [ICA, Slovak Academy of Sciences, 9, Dubravska Road, 845 03 Bratislava (Slovakia)

    2010-11-15

    Novel tubular light-guides with a transparent hemispherical cupola placed on an unobstructed flat roof collect all sunlight and skylight available at ground level year round. This advantage is heightened in the dry and sunny tropical regions where the sun rises to very high altitudes and often the hours of sunshine last throughout the whole day. Hollow light-guides with very high inner specular reflectances can transport sunbeams downward into the windowless building core very effectively. Due to the tube's diameter and length and multiple reflections, complex illuminance patterns are produced on the underside of the tube, i.e. on top of the glazed ceiling aperture that illuminates the interior space or its working plane. This paper discusses several daylight conditions in tropical interiors illuminated by tubular light-guides. The recently published HOLIGILM calculation program and the user-friendly tool HOLIGILM 4.2 have facilitated the production of this paper. (author)

  1. Acute tubular necrosis in a patient with paroxysmal nocturnal hemoglobinuria

    Directory of Open Access Journals (Sweden)

    Eranga S Wijewickrama

    2013-01-01

    Full Text Available Acute renal failure (ARF is a well-recognized complication of paroxysmal nocturnal hemoglobinuria (PNH. The predominant mechanism is intravascular hemolysis resulting in massive hemoglobinuria ARF. We report a case of acute tubular necrosis (ATN developed in the absence of overwhelming evidence of intravascular hemolysis in a 21-year-old man with anemia, who was eventually diagnosed to have PNH. The patient presented with rapidly deteriorating renal functions in the background of iron deficiency anemia, which was attributed to reflux esophagitis. There was no clinical or laboratory evidence of intravascular hemolysis. Renal biopsy revealed ATN with deposition of hemosiderin in the proximal tubular epithelial cells. Diagnosis of PNH was confirmed with a positive Ham′s test and flow cytometry. Our case emphasizes the need to consider ATN as a possible cause for ARF in patients suspected to have PNH even in the absence of overwhelming evidence of intravascular hemolysis.

  2. Registration of airborne LiDAR data and aerial images based on straight lines and POS data

    Science.gov (United States)

    Du, Quanye; Xu, Biao; Cao, Hui

    2009-10-01

    This paper presents a registration method which based on straight lines primitive. Firstly, 2D straight lines are extracted from aerial images using Canny operator and straight line fitting. In the similar way, 3D straight lines are extracted from LiDAR range images which derive from laser scanning point cloud. Secondly, 3D straight lines are projected to aerial images using collinearity equations and Position and Orientation System (POS) data. Then the corresponding lines are determined by straight line error. At last, each image's new exterior orientation elements are calculated by generalized point (straight line) photogrammetry.

  3. Renal tubular acidosis complicated with hyponatremia due to cortisol insufficiency

    OpenAIRE

    Izumi, Yuichiro; Nakayama, Yushi; Onoue, Tomoaki; Inoue, Hideki; Mukoyama, Masashi

    2015-01-01

    Adrenocortical insufficiency such as occurs in Addison's disease causes hyponatremia and renal tubular acidosis (RTA). Hyponatremia results from both aldosterone and cortisol insufficiency. RTA is due to aldosterone insufficiency. The involvement of cortisol in RTA is unclear. Here, we report a woman in her 70s who was admitted to our hospital with severe hyponatremia (106 mEq/l) and RTA. The patient exhibited low plasma cortisol levels with little response to rapid adrenocorticotropic hormon...

  4. Oscillations of manometric tubular springs with rigid end

    Science.gov (United States)

    Cherentsov, D. A.; Pirogov, S. P.; Dorofeev, S. M.; Ryabova, Y. S.

    2018-05-01

    The paper presents a mathematical model of attenuating oscillations of manometric tubular springs (MTS) taking into account the rigid tip. The dynamic MTS model is presented in the form of a thin-walled curved rod oscillating in the plane of curvature of the central axis. Equations for MTS oscillations are obtained in accordance with the d’Alembert principle in projections onto the normal and tangential. The Bubnov-Galerkin method is used to solve the equations obtained.

  5. CT diagnosis of intramedulear lesions of the tubular bone

    International Nuclear Information System (INIS)

    Wagner-Manslau, C.; Feuerbach, S.; Biehl, T.

    1985-01-01

    Three cases are used to demonstrate that intramedullary masses of the tubular bones can be discovered using computered tomography even when changes in the plain film are lacking or discrete. However, it was not possible to differentiate between osteomyelitis, chondrosarcoma and enchondroma owing to the identical morphology of these three diseases. Consequently, CT does not allow any statement on type and dignity and histological clarification is indispensable. (orig./WU) [de

  6. A tubular flux-switching permanent magnet machine

    Science.gov (United States)

    Wang, J.; Wang, W.; Clark, R.; Atallah, K.; Howe, D.

    2008-04-01

    The paper describes a novel tubular, three-phase permanent magnet brushless machine, which combines salient features from both switched reluctance and permanent magnet machine technologies. It has no end windings and zero net radial force and offers a high power density and peak force capability, as well as the potential for low manufacturing cost. It is, therefore, eminently suitable for a variety of applications, ranging from free-piston energy converters to active vehicle suspensions.

  7. CHARACTERISTICS OF CORN STALK HEMICELLULOSE PYROLYSIS IN A TUBULAR REACTOR

    OpenAIRE

    Gao-Jin Lv; Shu-Bin Wu; Rui Lou

    2010-01-01

    Pyrolysis characteristics of corn stalk hemicellulose were investigated in a tubular reactor at different temperatures, with focus mainly on the releasing profiles and forming behaviors of pyrolysis products (gas, char, and tar). The products obtained were further identified using various approaches (including GC, SEM, and GC-MS) to understand the influence of temperature on product properties and compositions. It was found that the devolatilization of hemicellulose mainly occurred at low tem...

  8. Distal renal tubular acidosis in recurrent renal stone formers

    DEFF Research Database (Denmark)

    Osther, P J; Hansen, A B; Røhl, H F

    1989-01-01

    Renal acidification ability was examined in 90 recurrent renal stone formers, using fasting morning urinary pH levels followed by a short ammonium chloride loading test in subjects with pH levels above 6.0. Fifteen patients (16.6%) revealed a distal renal tubular acidification defect: one patient......, this has important therapeutic implications. The pathological sequence in renal stone formers with dRTA is discussed....

  9. Effect of iron catalyst thickness on vertically aligned carbon nanotube forest straightness for CNT-MEMS

    International Nuclear Information System (INIS)

    Moulton, Kellen; Jensen, Brian D; Morrill, Nicholas B; Konneker, Adam M; Vanfleet, Richard R; Allred, David D; Davis, Robert C

    2012-01-01

    This paper examines the effect of iron catalyst thickness on the straightness of growth of carbon nanotubes (CNTs) for microelectromechanical systems fabricated using the CNT-templated-microfabrication (CNT-M) process. SEM images of samples grown using various iron catalyst thicknesses show that both straight sidewalls and good edge definition are achieved using an iron thickness between 7 and 8 nm. Below this thickness, individual CNTs are well aligned, but the sidewalls of CNT forests formed into posts and long walls are not always straight. Above this thickness, the CNT forest sidewalls are relatively straight, but edge definition is poor, with significantly increased sidewall roughness. The proximity of a device or feature to other regions of iron catalyst also affects CNT growth. By using an iron catalyst thickness appropriate for straight growth, and by adding borders of iron around features or devices, a designer can greatly improve straightness of growth for CNT-MEMS. (paper)

  10. Tubular transport and metabolism of cimetidine in chicken kidneys

    International Nuclear Information System (INIS)

    Rennick, B.; Ziemniak, J.; Smith, I.; Taylor, M.; Acara, M.

    1984-01-01

    Renal tubular transport and renal metabolism of [ 14 C]cimetidine (CIM) were investigated by unilateral infusion into the renal portal circulation in chickens (Sperber technique). [ 14 C]CIM was actively transported at a rate 88% that of simultaneously infused p-aminohippuric acid, and its transport was saturable. The following organic cations competitively inhibited the tubular transport of [ 14 C]CIM with decreasing potency: CIM, ranitidine, thiamine, procainamide, guanidine and choline. CIM inhibited the transport of [ 14 C]thiamine, [ 14 C]amiloride and [ 14 C]tetraethylammonium. During CIM infusion, two renal metabolites, CIM sulfoxide and hydroxymethylcimetidine, were found in urine. When CIM sulfoxide was infused, its transport efficiency was 32% and not saturable. CIM sulfoxide did ot inhibit the simultaneous renal tubular transport of p-aminohippuric acid or tetraethylammonium. CIM is transported by the organic cation transport system and the kidney metabolizes CIM. Transport of CIM and other cationic drugs could produce a drug interaction to alter drug excretion

  11. Mechanical testing of adherence of stacked layers in tubular geometry

    Energy Technology Data Exchange (ETDEWEB)

    Correia, L.A.; Schuring, E.W.; Van Delft, Y.C. [ECN Energy Efficiency in the Industry, Petten (Netherlands)

    2007-09-15

    For the development of new molecular separation technologies strong robust tubular membrane systems are required. The fragile membranes, however, need a strong defect free support such as a porous asymmetric ceramic tube. Mechanical failure of these ceramic membrane systems during manufacturing and operation is mainly caused by delamination of the stacked layers. Therefore development is focused on improving the adherence. As no standard mechanical test for tubular samples is available yet, a new tensile test was developed to facilitate the current research. The most important components in the new equipment is a test tool with a curvature matching that of the test sample and a sample casing that align and guide the test tool during the tensile test. With this tensile test the manufacturing procedure for the ECN standard tubular {alpha}-alumina support was optimized. Firing the asymmetric support at 1300C resulted in the highest mechanical strength for the support system with cohesive fracture in the support tube. With the test developed the process condition could be identified where the material of the support tube is the weakest link in the support system.

  12. Flow analysis of tubular fuel assembly using CFD code

    International Nuclear Information System (INIS)

    Park, J. H.; Park, C.; Chae, H. T.

    2004-01-01

    Based on the experiences of HANARO, a new research reactor is under conceptual design preparing for future needs of research reactor. Considering various aspects such as nuclear physics, thermal-hydraulics, mechanical structure and the applicability of HANARO technology, a tubular type fuel has been considered as that of a new research reactor. Tubular type fuel has several circular fuel layers, and each layer consists of 3 curved fuel plates arranged with constant small gap to build up cooling channels. In the thermal-hydraulic point, it is very important to maintain each channel flow velocity be equal as much as possible, because the small gaps between curved thin fuel plates independently forms separate coolant channels, which may cause a thermal-hydraulic problem in certain conditions. In this study, commercial CFD(Computational Fluid Dynamics) code, Fluent, has been used to investigate flow characteristics of tubular type fuel assembly. According to the computation results for the preliminary conceptual design, there is a serious lack of uniformity of average velocity on the each coolant channel. Some changes for initial conceptual design were done to improve the balance of velocity distribution, and analysis was done again, too. The results for the revised design showed that the uniformity of each channel velocity was improved significantly. The influence of outermost channel gap width on the velocity distribution was also examined

  13. A Tubular Biomaterial Construct Exhibiting a Negative Poisson's Ratio.

    Directory of Open Access Journals (Sweden)

    Jin Woo Lee

    Full Text Available Developing functional small-diameter vascular grafts is an important objective in tissue engineering research. In this study, we address the problem of compliance mismatch by designing and developing a 3D tubular construct that has a negative Poisson's ratio νxy (NPR. NPR constructs have the unique ability to expand transversely when pulled axially, thereby resulting in a highly-compliant tubular construct. In this work, we used projection stereolithography to 3D-print a planar NPR sheet composed of photosensitive poly(ethylene glycol diacrylate biomaterial. We used a step-lithography exposure and a stitch process to scale up the projection printing process, and used the cut-missing rib unit design to develop a centimeter-scale NPR sheet, which was rolled up to form a tubular construct. The constructs had Poisson's ratios of -0.6 ≤ νxy ≤ -0.1. The NPR construct also supports higher cellular adhesion than does the construct that has positive νxy. Our NPR design offers a significant advance in the development of highly-compliant vascular grafts.

  14. Plastic deformation of tubular crystals by dislocation glide.

    Science.gov (United States)

    Beller, Daniel A; Nelson, David R

    2016-09-01

    Tubular crystals, two-dimensional lattices wrapped into cylindrical topologies, arise in many contexts, including botany and biofilaments, and in physical systems such as carbon nanotubes. The geometrical principles of botanical phyllotaxis, describing the spiral packings on cylinders commonly found in nature, have found application in all these systems. Several recent studies have examined defects in tubular crystals associated with crystalline packings that must accommodate a fixed tube radius. Here we study the mechanics of tubular crystals with variable tube radius, with dislocations interposed between regions of different phyllotactic packings. Unbinding and separation of dislocation pairs with equal and opposite Burgers vectors allow the growth of one phyllotactic domain at the expense of another. In particular, glide separation of dislocations offers a low-energy mode for plastic deformations of solid tubes in response to external stresses, reconfiguring the lattice step by step. Through theory and simulation, we examine how the tube's radius and helicity affects, and is in turn altered by, the mechanics of dislocation glide. We also discuss how a sufficiently strong bending rigidity can alter or arrest the deformations of tubes with small radii.

  15. Filament winding technique, experiment and simulation analysis on tubular structure

    Science.gov (United States)

    Quanjin, Ma; Rejab, M. R. M.; Kaige, Jiang; Idris, M. S.; Harith, M. N.

    2018-04-01

    Filament winding process has emerged as one of the potential composite fabrication processes with lower costs. Filament wound products involve classic axisymmetric parts (pipes, rings, driveshafts, high-pressure vessels and storage tanks), non-axisymmetric parts (prismatic nonround sections and pipe fittings). Based on the 3-axis filament winding machine has been designed with the inexpensive control system, it is completely necessary to make a relative comparison between experiment and simulation on tubular structure. In this technical paper, the aim of this paper is to perform a dry winding experiment using the 3-axis filament winding machine and simulate winding process on the tubular structure using CADWIND software with 30°, 45°, 60° winding angle. The main result indicates that the 3-axis filament winding machine can produce tubular structure with high winding pattern performance with different winding angle. This developed 3-axis winding machine still has weakness compared to CAWIND software simulation results with high axes winding machine about winding pattern, turnaround impact, process error, thickness, friction impact etc. In conclusion, the 3-axis filament winding machine improvements and recommendations come up with its comparison results, which can intuitively understand its limitations and characteristics.

  16. A Role for Tubular Necroptosis in Cisplatin-Induced AKI

    Science.gov (United States)

    Xu, Yanfang; Ma, Huabin; Shao, Jing; Wu, Jianfeng; Zhou, Linying; Zhang, Zhirong; Wang, Yuze; Huang, Zhe; Ren, Junming; Liu, Suhuan; Chen, Xiangmei

    2015-01-01

    Cell death and inflammation in the proximal tubules are the hallmarks of cisplatin-induced AKI, but the mechanisms underlying these effects have not been fully elucidated. Here, we investigated whether necroptosis, a type of programmed necrosis, has a role in cisplatin-induced AKI. We found that inhibition of any of the core components of the necroptotic pathway—receptor-interacting protein 1 (RIP1), RIP3, or mixed lineage kinase domain-like protein (MLKL)—by gene knockout or a chemical inhibitor diminished cisplatin-induced proximal tubule damage in mice. Similar results were obtained in cultured proximal tubular cells. Furthermore, necroptosis of cultured cells could be induced by cisplatin or by a combination of cytokines (TNF-α, TNF-related weak inducer of apoptosis, and IFN-γ) that were upregulated in proximal tubules of cisplatin-treated mice. However, cisplatin induced an increase in RIP1 and RIP3 expression in cultured tubular cells in the absence of cytokine release. Correspondingly, overexpression of RIP1 or RIP3 enhanced cisplatin-induced necroptosis in vitro. Notably, inflammatory cytokine upregulation in cisplatin-treated mice was partially diminished in RIP3- or MLKL-deficient mice, suggesting a positive feedback loop involving these genes and inflammatory cytokines that promotes necroptosis progression. Thus, our data demonstrate that necroptosis is a major mechanism of proximal tubular cell death in cisplatin-induced nephrotoxic AKI. PMID:25788533

  17. Thermodynamic model and parametric analysis of a tubular SOFC module

    Science.gov (United States)

    Campanari, Stefano

    Solid oxide fuel cells (SOFCs) have been considered in the last years as one of the most promising technologies for very high-efficiency electric energy generation from natural gas, both with simple fuel cell plants and with integrated gas turbine-fuel cell systems. Among the SOFC technologies, tubular SOFC stacks with internal reforming have emerged as one of the most mature technology, with a serious potential for a future commercialization. In this paper, a thermodynamic model of a tubular SOFC stack, with natural gas feeding, internal reforming of hydrocarbons and internal air preheating is proposed. In the first section of the paper, the model is discussed in detail, analyzing its calculating equations and tracing its logical steps; the model is then calibrated on the available data for a recently demonstrated tubular SOFC prototype plant. In the second section of the paper, it is carried out a detailed parametric analysis of the stack working conditions, as a function of the main operating parameters. The discussion of the results of the thermodynamic and parametric analysis yields interesting considerations about partial load SOFC operation and load regulation, and about system design and integration with gas turbine cycles.

  18. Lacerations - liquid bandage

    Science.gov (United States)

    ... 2011:chap 28. Simon BC, Hern HG. Wound management principles. In: Marx JA, Hockberger RS, Walls RM, et al, eds. Rosen's Emergency Medicine: Concepts and Clinical Practice . 8th ed. Philadelphia, PA: Elsevier Saunders; 2014:chap ...

  19. Straight-bladed Darrieus wind turbines - A protagonist's view

    Science.gov (United States)

    Migliore, P. G.

    The technology development and market penetration of Darrieus and propeller-type wind turbines is addressed. Important characteristics of competing configurations are compared, and it is claimed that aerodynamic efficiency is not a distinguishing feature. Advantages of the Darrieus machine include omni-directionality and self-limitation, but propeller types require less rotor length per unit swept area. It is argued that the straight-bladed Darrieus is much simpler than the curved-bladed and should be capable of comparable aerodynamic efficiency. Some of the problems of structural design, as well as blade induced drag losses and support-arm counter torque, diminish rapidly as machine size is increased. Taper ratio has similar beneficial effects.

  20. UHV testing of spare straight section chambers of Indus-2

    International Nuclear Information System (INIS)

    Tiwari, S.K.; Ratnakala, K.C.; Sridhar, R.; Bhange, N.J.; Netram; Shukla, S.K.

    2015-01-01

    The vacuum system of Synchrotron Radiation Source, Indus-2, in RRCAT has been functioning up to the mark, continuously for last 10 years. To continue the same trouble-free functioning, it was planned to procure spares for all critical vacuum components, test for UHV performance and keep ready for installation, in case of requirement. As a part of this planning, fifteen chambers made of Aluminium alloy (6063 T6), procured as spare straight section chambers for Indus-2, and were tested for UHV performance. They were tested in batches of 2 or 3 chambers, depending upon their length, and the similar testing-procedure was followed. This paper narrates the tests carried out, and the results obtained. Ultimate vacuum in the range (2 to 9) x 10 -10 mbar was achieved. (author)

  1. Structural damping results from vibration tests of straight piping sections

    International Nuclear Information System (INIS)

    Ware, A.G.; Thinnes, G.L.

    1984-01-01

    EG and G Idaho is assisting the USNRC and the Pressure Vessel Research Committee in supporting a final position on revised damping values for structural analyses of nuclear piping systems. As part of this program, a series of vibrational tests on 76-mm and 203-mm (3-in. amd 8-in.) Schedule 40 carbon steel piping was conducted to determine the changes in structural damping due to various parametric effects. The 10-m (33-ft) straight sections of piping were rigidly supported at the ends. Spring, rod, and constant force hangers, as well as a sway brace and snubbers were included as intermediate supports. Excitation was provided by low-force level hammer inpacts, a hydraulic shaker, and a 445-kN (50-ton) overhead crane. Data was recorded using acceleration, strain, and displacement time histories. This paper presents results from the testing showing the effect of stress level and type of supports on structural damping in piping

  2. Plastic anisotropy of straight and cross rolled molybdenum sheets

    International Nuclear Information System (INIS)

    Oertel, C.-G.; Huensche, I.; Skrotzki, W.; Knabl, W.; Lorich, A.; Resch, J.

    2008-01-01

    The microstructure, texture and mechanical properties of molybdenum sheets produced by different rolling processes were investigated by orientation imaging in the scanning electron microscope, X-ray diffraction and tensile tests, respectively. For comparable recrystallization degree of the sheets investigated, straight rolling with low reduction ratio produces α-fiber textures with a maximum at {100} . At higher rolling degrees the maximum shifts to {112} . Cross rolling increases the rotated cube component {100} . The strong differences in the texture measured are reflected in the plastic anisotropy characterized by differences in the yield stress and Lankford parameter which were measured along directions in the rolling plane at angles of 0 deg., 45 deg. and 90 deg. with the rolling direction. The Taylor-Bishop-Hill theory is used successfully to qualitatively explain the plastic anisotropy

  3. Lateral convection and diffusion of sediment in straight rivers

    DEFF Research Database (Denmark)

    Christensen, Henrik Bo; Fredsøe, Jørgen

    1998-01-01

    and a higher level of turbulence at the channel centre, than in the near bank zones, which means that the ability to support suspended sediment will decrease from the channel centre. The two turbulence models give different estimates for the lateral transport, which mainly are caused by turbulence generated......The lateral transport of suspended sediment in a straight river cross section with a parabolic shaped bed is studied be use of a k-e and a full Reynolds stress turbulence model. Due to depth variations a lateral transport of suspended sediment is generated. This is mainly caused by the slopping bed...... secondary flow cells in the Reynolds stress model. The flow cells make zones with alternately high and low sediment concentration, and thereby much higher local gradients in the lateral direction. Both models found a net inward lateral transport. The transport by convection was found more dominant than...

  4. Thermal Performance of the LHC Short Straight Section Cryostat

    CERN Document Server

    Bergot, J B; Nielsen, L; Parma, Vittorio; Rohmig, P; Roy, E

    2002-01-01

    The LHC Short Straight Section (SSS) cryostat houses and thermally protects in vacuum the cold mass which contains a twin-aperture superconducting quadrupole magnet and superconducting corrector magnets operating at 1.9 K in superfluid helium. In addition to mechanical requirements, the cryostat is designed to minimize the heat in-leak from the ambient temperature to the cold mass. Mechanical components linking the cold mass to the vacuum vessel such as support posts and an insulation vacuum barrier are designed to have minimum heat conductivity with efficient thermalisations for heat interception. Heat in-leak by radiation is reduced by employing multilayer insulation wrapped around the cold mass and an actively cooled aluminium thermal shield. The recent commissioning and operation of two SSS prototypes in the LHC Test String 2 have given a first experimental validation of the thermal performance of the SSS cryostat in nominal operating conditions. Temperature sensors mounted in critical locations provide a...

  5. Mathematical modeling of methyl ester concentration distribution in a continuous membrane tubular reactor and comparison with conventional tubular reactor

    Science.gov (United States)

    Talaghat, M. R.; Jokar, S. M.; Modarres, E.

    2017-10-01

    The reduction of fossil fuel resources and environmental issues made researchers find alternative fuels include biodiesels. One of the most widely used methods for production of biodiesel on a commercial scale is transesterification method. In this work, the biodiesel production by a transesterification method was modeled. Sodium hydroxide was considered as a catalyst to produce biodiesel from canola oil and methanol in a continuous tubular ceramic membranes reactor. As the Biodiesel production reaction from triglycerides is an equilibrium reaction, the reaction rate constants depend on temperature and related linearly to catalyst concentration. By using the mass balance for a membrane tubular reactor and considering the variation of raw materials and products concentration with time, the set of governing equations were solved by numerical methods. The results clearly show the superiority of membrane reactor than conventional tubular reactors. Afterward, the influences of molar ratio of alcohol to oil, weight percentage of the catalyst, and residence time on the performance of biodiesel production reactor were investigated.

  6. Bioinspired coupled helical coils for soft tissue engineering of tubular structures - Improved mechanical behavior of tubular collagen type I templates.

    Science.gov (United States)

    Janke, H P; Bohlin, J; Lomme, R M L M; Mihaila, S M; Hilborn, J; Feitz, W F J; Oosterwijk, E

    2017-09-01

    The design of constructs for tubular tissue engineering is challenging. Most biomaterials need to be reinforced with supporting structures such as knittings, meshes or electrospun material to comply with the mechanical demands of native tissues. In this study, coupled helical coils (CHCs) were manufactured to mimic collagen fiber orientation as found in nature. Monofilaments of different commercially available biodegradable polymers were wound and subsequently fused, resulting in right-handed and left-handed polymer helices fused together in joints where the filaments cross. CHCs of different polymer composition were tested to determine the tensile strength, strain recovery, hysteresis, compressive strength and degradation of CHCs of different composition. Subsequently, seamless and stable hybrid constructs consisting of PDSII® USP 2-0 CHCs embedded in porous collagen type I were produced. Compared to collagen alone, this hybrid showed superior strain recovery (93.5±0.9% vs 71.1±12.6% in longitudinal direction; 87.1±6.6% vs 57.2±4.6% in circumferential direction) and hysteresis (18.9±2.7% vs 51.1±12.0% in longitudinal direction; 11.5±4.6% vs 46.3±6.3% in circumferential direction). Furthermore, this hybrid construct showed an improved Young's modulus in both longitudinal (0.5±0.1MPavs 0.2±0.1MPa; 2.5-fold) and circumferential (1.65±0.07MPavs (2.9±0.3)×10 -2 MPa; 57-fold) direction, respectively, compared to templates created from collagen alone. Moreover, hybrid template characteristics could be modified by changing the CHC composition and CHCs were produced showing a mechanical behavior similar to the native ureter. CHC-enforced templates, which are easily tunable to meet different demands may be promising for tubular tissue engineering. Most tubular constructs lack sufficient strength and tunability to comply with the mechanical demands of native tissues. Therefore, we embedded coupled helical coils (CHCs) produced from biodegradable polymers - to

  7. A young woman with recurrent kidney stones: questions on hypokalaemic tubular acidosis

    Directory of Open Access Journals (Sweden)

    Jill Vanmassenhove

    2017-04-01

    Full Text Available This paper discusses the diagnostic and therapeutic approach to the problem of a young woman presenting with recurrent kidney stones. In the clinical work-up, a hypokalaemic normal anion gap metabolic acidosis was found. The diagnostic tests to solve this common clinical problem and some therapeutic recommendations are discussed. Question on hypokalaemic tubular acidosis: 1. What is the significance of the plasma anion gap (PAG? 2. How does one appreciate the respiratory component of the acid base status? 3. How does one perform tests for tubular acidification disturbances? 4. What is the pathogenesis of distal tubular acidification ­disturbances? 5. What is the explanation of the hypokalaemia in distal ­tubular acidosis? 6. What is the pathogenesis of nephrolithiasis in distal tubular acidosis? 7. How does one treat a patient with distal tubular acidosis and recurrent nephrolithiasis?

  8. Drill pipes and casings utilizing multi-conduit tubular; Flerkanals roerstreng

    Energy Technology Data Exchange (ETDEWEB)

    Curlett, H.B.

    1997-04-23

    The invention relates to a multi-conduit tubular having fluid conduits and electrical conduits, with associated surface fluid and electrical commutators, and downhole sensors for providing surface monitors with instantaneous formation data. Each tubular includes a plurality of uniform linear conduits there through, with a gasket seal plate interposed between joined tubular for assuring a high pressure seal between joined conduits. the seal plate includes an intermediate electrical connector for connecting electrical conduit connectors of one tubular to another. A coupling collar with uniform diameter internal coarse and fine threads joins the tubular ends having similar threads by differential thread action without respective tubular rotation. Each tubular end includes an inter-engaging index recess and index lug, and drive recesses and lugs for maintaining angular registry of the tubular string and for driving one drill tubular with another. A fluid commutator includes a rotating shaft with passages connected to the tubular conduits, and rotating in a manifold having annular grooves in communication with the shaft passages and external fluid sources. An adaptor couples each commutator shaft passage to one or more tubular conduits. Slip rings on a quill shaft and stationary brush means provide electrical continuity from the electrical conduit wires to surface equipment. A cross-over sub includes formation parameter sensors and telemetry equipment in a blocked off portion of a fluid conduit. An annular accumulator connected with the well bore annulus applies a pressure thereto in response to downhole sensors to change the effective density of the drill mud. The multi-conduit tubular is further adapted for use as a well casing to provide downhole access of a plurality of fluids and electrical parameter sensors. 28 figs.

  9. Generation of Urinary Albumin Fragments Does Not Require Proximal Tubular Uptake

    OpenAIRE

    Weyer, K.; Nielsen, R.; Christensen, E. I.; Birn, H.

    2012-01-01

    Urinary albumin excretion is an important diagnostic and prognostic marker of renal function. Both animal and human urine contain large amounts of albumin fragments, but whether these fragments originate from renal tubular degradation of filtered albumin is unknown. Here, we used mice with kidneys lacking megalin and cubilin, the coreceptors that mediate proximal tubular endocytosis of albumin, to determine whether proximal tubular degradation of albumin forms the detectable urinary albumin f...

  10. Gay-Straight Alliance (GSA) Members' Engagement with Sex Education in Canadian High Schools

    Science.gov (United States)

    Lapointe, Alicia

    2014-01-01

    This paper offers an examination of gay-straight alliance (GSA) members' engagement with sex education, sexual health, and prejudice and discrimination in Canadian public high schools. It explores how five students' (four straight and one gay-identifying) participation in GSAs served as a springboard for learning about and challenging stereotypes;…

  11. Standing down Straight: Jump Rhythm Technique's Rhythm-Driven, Community-Directed Approach to Dance Education

    Science.gov (United States)

    Siegenfeld, Billy

    2009-01-01

    "Standing down straight" means to stand on two feet with both stability and relaxation. Using standing down straight as the foundation of class work, Jump Rhythm Technique offers a fresh alternative to conventional systems of dance study. It bases its pedagogy on three behaviors: grounding the body so that it can move with power and efficiency,…

  12. Spherical Projection Based Straight Line Segment Extraction for Single Station Terrestrial Laser Point Cloud

    Directory of Open Access Journals (Sweden)

    ZHANG Fan

    2015-06-01

    Full Text Available Due to the discrete distribution computing errors and lack of adaptability are ubiquitous in the current straight line extraction for TLS data methods. A 3D straight line segment extraction method is proposed based on spherical projection for single station terrestrial laser point clouds. Firstly, horizontal and vertical angles of each laser point are calculated by means of spherical coordinates, intensity panoramic image according to the two angles is generated. Secondly, edges which include straight line features are detected from intensity panoramic image by using of edge detection algorithm. Thirdly, great circles are detected from edges of panoramic image using spherical Hough transform. According to the axiom that a straight line segment in 3D space is a spherical great circle after spherical projection, detecting great circles from spherical projected data sets is essentially detecting straight line segments from 3D data sets without spherical projection. Finally, a robust 3D straight line fitting method is employed to fitting the straight lines and calculating parameters of the straight line segments. Experiments using different data sets and comparison with other methods show the accuracy and applicability of the proposed method.

  13. A simple algorithm for computing positively weighted straight skeletons of monotone polygons☆

    Science.gov (United States)

    Biedl, Therese; Held, Martin; Huber, Stefan; Kaaser, Dominik; Palfrader, Peter

    2015-01-01

    We study the characteristics of straight skeletons of monotone polygonal chains and use them to devise an algorithm for computing positively weighted straight skeletons of monotone polygons. Our algorithm runs in O(nlog⁡n) time and O(n) space, where n denotes the number of vertices of the polygon. PMID:25648376

  14. A simple algorithm for computing positively weighted straight skeletons of monotone polygons.

    Science.gov (United States)

    Biedl, Therese; Held, Martin; Huber, Stefan; Kaaser, Dominik; Palfrader, Peter

    2015-02-01

    We study the characteristics of straight skeletons of monotone polygonal chains and use them to devise an algorithm for computing positively weighted straight skeletons of monotone polygons. Our algorithm runs in [Formula: see text] time and [Formula: see text] space, where n denotes the number of vertices of the polygon.

  15. The role of duplex stainless steels for downhole tubulars

    International Nuclear Information System (INIS)

    Francis, R.

    1993-01-01

    In sour conditions there is an increasing trend to turn to corrosion resistant alloys for downhole tubulars. The most commonly used CRA tubular is 13Cr, and there are thousands of feet in service. However, there are limits to the use of 13Cr, ie., the risk of sulphide stress corrosion cracking at high H 2 S levels, and the possibility of pitting or high corrosion rates in waters with high chloride contents. Where the service conditions are felt to be too severe for 13Cr alloys it has been traditional to switch to nickel base alloys such as alloys 825 and C-276 (UNS N08825 and N10276). The alloys are much more expensive than 13Cr, and in recent years the duplex stainless steels have been selected as alloys with superior corrosion and SSCC resistance compared with 13Cr, and having lower cost than nickel alloys. Originally the 22Cr duplex alloy (UNS 31803) was used, but more recently the 25Cr super duplex alloys (UNS S32760 and S32750) have become more available. The present paper reviews the data available for 13Cr and the limits of applicability. Data is also presented for laboratory tests for both the 22Cr and 25Cr super duplex alloys. There is extensive service experience with both 22Cr and 25Cr super duplex in the North Sea, covering both downhole tubulars, manifold and post wellhead equipment. Data is presented showing some of the sour condition being experienced in the North Sea by super duplex alloys. These results show that there is a substantial gap between the limits of use for 13Cr and the 25Cr super duplex stainless steel alloys. This means that in many sour environments super duplex stainless steel provides a cost effective alternative to nickel-base alloys

  16. Tubular overexpression of gremlin induces renal damage susceptibility in mice.

    Directory of Open Access Journals (Sweden)

    Alejandra Droguett

    Full Text Available A growing number of patients are recognized worldwide to have chronic kidney disease. Glomerular and interstitial fibrosis are hallmarks of renal progression. However, fibrosis of the kidney remains an unresolved challenge, and its molecular mechanisms are still not fully understood. Gremlin is an embryogenic gene that has been shown to play a key role in nephrogenesis, and its expression is generally low in the normal adult kidney. However, gremlin expression is elevated in many human renal diseases, including diabetic nephropathy, pauci-immune glomerulonephritis and chronic allograft nephropathy. Several studies have proposed that gremlin may be involved in renal damage by acting as a downstream mediator of TGF-β. To examine the in vivo role of gremlin in kidney pathophysiology, we generated seven viable transgenic mouse lines expressing human gremlin (GREM1 specifically in renal proximal tubular epithelial cells under the control of an androgen-regulated promoter. These lines demonstrated 1.2- to 200-fold increased GREM1 expression. GREM1 transgenic mice presented a normal phenotype and were without proteinuria and renal function involvement. In response to the acute renal damage cause by folic acid nephrotoxicity, tubule-specific GREM1 transgenic mice developed increased proteinuria after 7 and 14 days compared with wild-type treated mice. At 14 days tubular lesions, such as dilatation, epithelium flattening and hyaline casts, with interstitial cell infiltration and mild fibrosis were significantly more prominent in transgenic mice than wild-type mice. Tubular GREM1 overexpression was correlated with the renal upregulation of profibrotic factors, such as TGF-β and αSMA, and with increased numbers of monocytes/macrophages and lymphocytes compared to wild-type mice. Taken together, our results suggest that GREM1-overexpressing mice have an increased susceptibility to renal damage, supporting the involvement of gremlin in renal damage

  17. The rebirth of interest in renal tubular function.

    Science.gov (United States)

    Lowenstein, Jerome; Grantham, Jared J

    2016-06-01

    The measurement of glomerular filtration rate by the clearance of inulin or creatinine has evolved over the past 50 years into an estimated value based solely on plasma creatinine concentration. We have examined some of the misconceptions and misunderstandings of the classification of renal disease and its course, which have followed this evolution. Furthermore, renal plasma flow and tubular function, which in the past were estimated by the clearance of the exogenous aryl amine, para-aminohippurate, are no longer measured. Over the past decade, studies in experimental animals with reduced nephron mass and in patients with reduced renal function have identified small gut-derived, protein-bound uremic retention solutes ("uremic toxins") that are poorly filtered but are secreted into the lumen by organic anion transporters (OATs) in the proximal renal tubule. These are not effectively removed by conventional hemodialysis or peritoneal dialysis. Residual renal function, urine produced in patients with advanced renal failure or undergoing dialysis treatment, may represent, at least in part, secretion of fluid and uremic toxins, such as indoxyl sulfate, mediated by proximal tubule OATs and might serve as a useful survival function. In light of this new evidence of the physiological role of proximal tubule OATs, we suggest that measurement of renal tubular function and renal plasma flow may be of considerable value in understanding and managing chronic kidney disease. Data obtained in normal subjects indicate that renal plasma flow and renal tubular function might be measured by the clearance of the endogenous aryl amine, hippurate. Copyright © 2016 the American Physiological Society.

  18. Stem cell factor expression after renal ischemia promotes tubular epithelial survival.

    Directory of Open Access Journals (Sweden)

    Geurt Stokman

    Full Text Available BACKGROUND: Renal ischemia leads to apoptosis of tubular epithelial cells and results in decreased renal function. Tissue repair involves re-epithelialization of the tubular basement membrane. Survival of the tubular epithelium following ischemia is therefore important in the successful regeneration of renal tissue. The cytokine stem cell factor (SCF has been shown to protect the tubular epithelium against apoptosis. METHODOLOGY/PRINCIPAL FINDINGS: In a mouse model for renal ischemia/reperfusion injury, we studied how expression of c-KIT on tubular epithelium and its ligand SCF protect cells against apoptosis. Administration of SCF specific antisense oligonucleotides significantly decreased specific staining of SCF following ischemia. Reduced SCF expression resulted in impaired renal function, increased tubular damage and increased tubular epithelial apoptosis, independent of inflammation. In an in vitro hypoxia model, stimulation of tubular epithelial cells with SCF activated survival signaling and decreased apoptosis. CONCLUSIONS/SIGNIFICANCE: Our data indicate an important role for c-KIT and SCF in mediating tubular epithelial cell survival via an autocrine pathway.

  19. Vibration analysis and sound field characteristics of a tubular ultrasonic radiator.

    Science.gov (United States)

    Liang, Zhaofeng; Zhou, Guangping; Zhang, Yihui; Li, Zhengzhong; Lin, Shuyu

    2006-12-01

    A sort of tubular ultrasonic radiator used in ultrasonic liquid processing is studied. The frequency equation of the tubular radiator is derived, and its radiated sound field in cylindrical reactor is calculated using finite element method and recorded by means of aluminum foil erosion. The results indicate that sound field of tubular ultrasonic radiator in cylindrical reactor appears standing waves along both its radial direction and axial direction, and amplitudes of standing waves decrease gradually along its radial direction, and the numbers of standing waves along its axial direction are equal to the axial wave numbers of tubular radiator. The experimental results are in good agreement with calculated results.

  20. A laser interferometer for measuring straightness and its position based on heterodyne interferometry

    International Nuclear Information System (INIS)

    Chen Benyong; Zhang Enzheng; Yan Liping; Li Chaorong; Tang Wuhua; Feng Qibo

    2009-01-01

    Not only the magnitude but also the position of straightness errors are of concern to users. However, current laser interferometers used for measuring straightness seldom give the relative position of the straightness error. To solve this problem, a laser interferometer for measuring straightness and its position based on heterodyne interferometry is proposed. The optical configuration of the interferometer is designed and the measurement principle is analyzed theoretically. Two experiments were carried out. The first experiment verifies the validity and repeatability of the interferometer by measuring a linear stage. Also, the second one for measuring a flexure-hinge stage demonstrates that the interferometer is capable of nanometer measurement accuracy. These results show that this interferometer has advantages of simultaneously measuring straightness error and the relative position with high precision, and a compact structure.

  1. Theoretical flow investigations of an all glass evacuated tubular collector

    DEFF Research Database (Denmark)

    Shah, Louise Jivan; Furbo, Simon

    2007-01-01

    Heat transfer and flow structures inside all glass evacuated tubular collectors for different operating conditions are investigated by means of computational fluid dynamics. The investigations are based on a collector design with horizontal tubes connected to a vertical 14 manifold channel. Three...... the highest efficiency, the optimal inlet flow rate was around 0.4-1 kg/min, the flow structures in the glass tubes were relatively uninfluenced by the inlet flow rate, Generally, the results showed only small variations in the efficiencies. This indicates that the collector design is well working for most...

  2. Use of graphite layer open tubular (GLOT) in environmental analysis

    International Nuclear Information System (INIS)

    Bruner, F.; Lattanzi, L.; Borghesi, P.

    1996-01-01

    Recently it has been developed a series of new capillary columns characterised by the use of graphitized carbon black modified from different amount of liquid phase. The characteristics of these columns, called graphite layer open tubular (GLOT), are described together with their application to the environmental analysis. A specific application of GLOT columns is for the direct analysis of aqueous solutions avoiding solvent extraction procedure. A comparison between a GLOT column and a traditional capillary column, estimating their behaviour after repeated direct injections of aqueous solution sample is written. Some applications regarding the analysis of the atmosphere pollutants, as aliphatic and aromatic hydrocarbons, and their compounds are written too

  3. Distal renal tubular acidosis and amelogenesis imperfecta: A rare association

    Directory of Open Access Journals (Sweden)

    P Ravi

    2013-01-01

    Full Text Available Renal tubular acidosis (RTA is characterized by a normal anion gap with hyperchloremic metabolic acidosis. Primary distal RTA (type I is the most common RTA in children. Childhood presentation of distal RTA includes vomiting, failure to thrive, metabolic acidosis, and hypokalemia. Amelogenesis imperfecta (AI represents a condition where the dental enamel and oral tissues are affected in an equal manner resulting in the hypoplastic or hypopigmented teeth. We report a 10-year-old girl, previously asymptomatic presented with the hypokalemic paralysis and on work-up found out to have type I RTA. The discoloration of teeth and enamel was diagnosed as AI.

  4. Screening renal stone formers for distal renal tubular acidosis

    DEFF Research Database (Denmark)

    Osther, P J; Hansen, A B; Røhl, H F

    1989-01-01

    A group of 110 consecutive renal stone formers were screened for distal renal tubular acidosis (RTA) using morning fasting urinary pH (mfUpH) levels followed by a short ammonium chloride loading test in patients with levels above 6.0. In 14 patients (12.7%) a renal acidification defect was noted...... RTA in renal stone formers. Regardless of whether the acidification defect is primary or secondary to stone formation, however, all renal stone formers with distal RTA can expect to benefit from prophylactic alkaline therapy and it is recommended that the screening procedure, which is easy to use...

  5. Defect Depth Measurement of Straight Pipe Specimen Using Shearography

    International Nuclear Information System (INIS)

    Chang, Ho Seob; Kim, Kyung Suk

    2012-01-01

    In the nuclear industry, wall thinning defect of straight pipe occur the enormous loss in life evaluation and safety evaluation. To use non-destructive technique, we measure deformation, vibration, defect evaluation. But, this techniques are a weak that is the measurement of the wide area is difficult and the time is caught long. In the secondary side of nuclear power plants mostly used steel pipe, artificiality wall thinning defect make in the side and different thickness make to the each other, wall thinning defect part of deformation measure by using shearography. In addition, optical measurement through deformation, vibration, defect evaluation evaluate pipe and thickness defects of pressure vessel is to evaluate quantitatively. By shearography interferometry to measure the pipe's internal wall thinning defect and the variation of pressure use the proposed technique, the quantitative defect is to evaluate the thickness of the surplus. The amount of deformation use thickness of surplus prediction of the actual thickness defect and approximately 7 percent error by ensure reliability. According to pressure the amount of deformation and the thickness of the surplus through DB construction, nuclear power plant pipe use wall thinning part soundness evaluation. In this study, pressure vessel of thickness defect measure proposed nuclear pipe of wall thinning defect prediction and integrity assessment technology development. As a basic research defected theory and experiment, pressure vessel of advanced stability and soundness and maintainability is expected to contribute foundation establishment

  6. Youth Empowerment and High School Gay-Straight Alliances

    Science.gov (United States)

    Muraco, Anna; Subramaniam, Aarti; Laub, Carolyn

    2010-01-01

    In the field of positive youth development programs, “empowerment” is used interchangeably with youth activism, leadership, civic participation and self-efficacy. However, few studies have captured what empowerment means to young people in diverse contexts. This article explores how youth define and experience empowerment in youth-led organizations characterized by social justice goals: high school Gay-Straight Alliances (GSAs). Through focus group interviews, fifteen youth leaders of GSAs from different regions of California explain what they think empowerment means and how they became empowered through their involvement with the GSA. Youth describe three inter-related dimensions of empowerment: personal empowerment, relational empowerment, and strategic empowerment through having and using knowledge. When these three dimensions are experienced in combination, GSA leaders have the potential for individual and collective empowerment as agents of social change at school. By understanding these youth's perspectives on the meanings of empowerment, this article clarifies the conceptual arena for future studies of socially marginalized youth and of positive youth development. PMID:19636734

  7. A composite vacuum barrier for the LHC short straight section

    International Nuclear Information System (INIS)

    Jenny, B.; Rohmig, P.; Uriarte, J.M.

    1996-01-01

    The lattice of the CERN Large Hadron Collider (LHC) will contain 384 Short Straight Section (SSS) units, one in every 53 m half-cell. The SSS is composed of a twin aperture high-field superconducting quadrupole and of two combined-function corrector magnets operating in pressurized helium at 1.9 K. The SSS cryostat contains also a barrier for sectorisation of the insulation vacuum. The vacuum barrier is mounted between the helium vessel and the vacuum enclosure. Its functions are to limit the extent of eventual helium leaks and to facilitate the leak detection and the pumping-down from atmospheric pressure. During installation of the LHC, the vacuum barrier permits independent testing of the half-cells, thus enabling higher installation rates. In parallel to a conventional barrier made out of austenitic stainless steel, a barrier of composite material was developed, taking advantage of the lower thermal conductivity of glass fibre reinforced epoxy resin, and with the aim of reducing costs for LHC. The thermo-mechanical design together with the conception and the moulding techniques used for the manufacture of the prototype are described. Bonding techniques for the leak tight stainless steel composite interfaces are presented and test results shown. Results on the mechanical performance and on the helium tests carried out on the prototype are given

  8. Straight cylindrical seal for high-performance turbomachines

    Science.gov (United States)

    Hendricks, Robert C.

    1987-01-01

    A straight cylindrical seal configuration representing the seal for a high-performance turbopump (e.g., the space shuttle main engine fuel pump) was tested under static (nonrotating) conditions. The test data included critical mass flux and pressure profiles over a wide range of inlet temperatures and pressures for fluid nitrogen and fluid hydrogen with the seal in concentric and fully eccentric positions. The critical mass fluxes (or leakage rates) for the concentric and fully eccentric configurations were nearly the same when based on stagnation conditions upstream of the seal. The fully eccentric configuration pressure profiles of the gas and liquid were different. Further, the pressure differences between the maximum and the minimum clearance positions were highly dependent on the geometric conditions, the temperature, and the absolute pressure at both the inlet and the exit. The pressure differences were greatest in the inlet region. The results, although complex, tend to follow the corresponding-states principles for critical flows. Gaseous injection near the seal exit plane significantly altered the pressure profiles and could be used to control turbomachine instabilities.

  9. Receptivity of Hypersonic Boundary Layers over Straight and Flared Cones

    Science.gov (United States)

    Balakumar, Ponnampalam; Kegerise, Michael A.

    2010-01-01

    The effects of adverse pressure gradients on the receptivity and stability of hypersonic boundary layers were numerically investigated. Simulations were performed for boundary layer flows over a straight cone and two flared cones. The steady and the unsteady flow fields were obtained by solving the two-dimensional Navier-Stokes equations in axi-symmetric coordinates using the 5th order accurate weighted essentially non-oscillatory (WENO) scheme for space discretization and using third-order total-variation-diminishing (TVD) Runge-Kutta scheme for time integration. The mean boundary layer profiles were analyzed using local stability and non-local parabolized stability equations (PSE) methods. After the most amplified disturbances were identified, two-dimensional plane acoustic waves were introduced at the outer boundary of the computational domain and time accurate simulations were performed. The adverse pressure gradient was found to affect the boundary layer stability in two important ways. Firstly, the frequency of the most amplified second-mode disturbance was increased relative to the zero pressure gradient case. Secondly, the amplification of first- and second-mode disturbances was increased. Although an adverse pressure gradient enhances instability wave growth rates, small nose-tip bluntness was found to delay transition due to the low receptivity coefficient and the resulting weak initial amplitude of the instability waves. The computed and measured amplitude-frequency spectrums in all three cases agree very well in terms of frequency and the shape except for the amplitude.

  10. Youth empowerment and high school Gay-Straight Alliances.

    Science.gov (United States)

    Russell, Stephen T; Muraco, Anna; Subramaniam, Aarti; Laub, Carolyn

    2009-08-01

    In the field of positive youth development programs, "empowerment" is used interchangeably with youth activism, leadership, civic participation and self-efficacy. However, few studies have captured what empowerment means to young people in diverse contexts. This article explores how youth define and experience empowerment in youth-led organizations characterized by social justice goals: high school Gay-Straight Alliances (GSAs). Through focus group interviews, fifteen youth leaders of GSAs from different regions of California explain what they think empowerment means and how they became empowered through their involvement with the GSA. Youth describe three inter-related dimensions of empowerment: personal empowerment, relational empowerment, and strategic empowerment through having and using knowledge. When these three dimensions are experienced in combination, GSA leaders have the potential for individual and collective empowerment as agents of social change at school. By understanding these youth's perspectives on the meanings of empowerment, this article clarifies the conceptual arena for future studies of socially marginalized youth and of positive youth development.

  11. Electrical and Magnetic Performance of the LHC Short Straight Sections

    CERN Document Server

    Sanfilippo, S; Bottura, L; Buzio, M; Coccoli, M; García-Pérez, J; Pugnat, P; Sammut, N; Siemko, A; Smirnov, N; Stafiniak, A; Wildner, E

    2006-01-01

    The Short Straight Section (SSS) for the Large Hadron Collider arcs, containing in a common cryostat the lattice quadrupoles and correction magnets, have now entered series production. The foremost features of the lattice quadrupole magnets are a two-in-one structure containing two 56 mm aperture, two-layers coils wound from 15.1 mm wide NbTi cables, enclosed by the stainless steel collars and ferromagnetic yoke, and inserted into the inertia tube. Systematic cryogenic tests are performed at CERN in order to qualify these magnets with respect to their cryogenic and electrical integrity, the quench performance and the field quality in all operating conditions. This paper reports the main results obtained during tests and measurements in superfluid helium. The electrical characteristics, the insulation measurements and the quench performance are compared to the specifications and expected performances for these magnets. The field in the main quadrupole is measured using three independent systems: 10-m lon...

  12. Nano-tubular cellulose for bioprocess technology development.

    Science.gov (United States)

    Koutinas, Athanasios A; Sypsas, Vasilios; Kandylis, Panagiotis; Michelis, Andreas; Bekatorou, Argyro; Kourkoutas, Yiannis; Kordulis, Christos; Lycourghiotis, Alexis; Banat, Ibrahim M; Nigam, Poonam; Marchant, Roger; Giannouli, Myrsini; Yianoulis, Panagiotis

    2012-01-01

    Delignified cellulosic material has shown a significant promotional effect on the alcoholic fermentation as yeast immobilization support. However, its potential for further biotechnological development is unexploited. This study reports the characterization of this tubular/porous cellulosic material, which was done by SEM, porosimetry and X-ray powder diffractometry. The results showed that the structure of nano-tubular cellulose (NC) justifies its suitability for use in "cold pasteurization" processes and its promoting activity in bioprocessing (fermentation). The last was explained by a glucose pump theory. Also, it was demonstrated that crystallization of viscous invert sugar solutions during freeze drying could not be otherwise achieved unless NC was present. This effect as well as the feasibility of extremely low temperature fermentation are due to reduction of the activation energy, and have facilitated the development of technologies such as wine fermentations at home scale (in a domestic refrigerator). Moreover, NC may lead to new perspectives in research such as the development of new composites, templates for cylindrical nano-particles, etc.

  13. Rhabdomyolysis with acute tubular necrosis following occupational inhalation of thinners.

    Science.gov (United States)

    Ngajilo, D; Ehrlich, R

    2017-07-01

    Thinners are mixtures of organic solvents commonly containing toluene, xylene, acetone, hexane, benzene and methyl isobutyl ketone. This report describes a case of rhabdomyolysis with acute tubular necrosis and renal failure, most likely attributable to toluene, following occupational exposure to thinners while cleaning a steel water tank. These adverse health effects have previously been reported following acute poisoning or intentional inhalation by drug abusers, but rarely in the occupational setting. Poor working conditions, lack of health and safety training and delayed treatment contributed to the onset and severity of the patient's complications. This case emphasizes the need for strict control measures, including adequate ventilation, training on working in confined spaces, appropriate personal protective equipment and emergency rescue procedures in such settings. In addition, rhabdomyolysis, acute tubular necrosis and renal failure should be added to safety data material as possible complications of excessive inhalation of thinners. © The Author 2017. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Advances in tubular solid oxide fuel cell technology

    Energy Technology Data Exchange (ETDEWEB)

    Singhal, S.C. [Westinghouse Electric Corp., Pittsburgh, PA (United States)

    1996-12-31

    The design, materials and fabrication processes for the earlier technology Westinghouse tubular geometry cell have been described in detail previously. In that design, the active cell components were deposited in the form of thin layers on a ceramic porous support tube (PST). The tubular design of these cells and the materials used therein have been validated by successful electrical testing for over 65,000 h (>7 years). In these early technology PST cells, the support tube, although sufficiently porous, presented an inherent impedance to air flow toward air electrode. In order to reduce such impedance to air flow, the wall thickness of the PST was first decreased from the original 2 mm (the thick-wall PST) to 1.2 mm (the thin-wall PST). The calcia-stabilized zirconia support tube has now been completely eliminated and replaced by a doped lanthanum manganite tube in state-of-the-art SOFCs. This doped lanthanum manganite tube is extruded and sintered to about 30 to 35 percent porosity, and serves as the air electrode onto which the other cell components are fabricated in thin layer form. These latest technology cells are designated as air electrode supported (AES) cells.

  15. Carbohydrates in Ankistrodesmus braunii biomass cultivated in tubular photobioreactors

    Directory of Open Access Journals (Sweden)

    Ana Lucía Morocho-Jácome

    2017-12-01

    Full Text Available The great need for microalgae biomass production in tubular photobioreactors has increased for use in biofuels, pharmaceuticals and even cosmetic applications. In order to better understand the potential applications of this material, it is imperative to know in detail its composition. Ankistrodesmus braunii was cultivated in 3.5 L tubular air-lift photobioreactors using 10 mM sodium nitrate as nitrogen source in batch mode at 60 µmol photons m-2 s-1. The maximum biomass concentration (Xm and the biomass productivity (PX reached at 6th day of cultivation was 1249 ± 72 mg L-1 and 165 ± 13 mg L-1 d-1, respectively. Carbohydrates productivity expressed in terms of glucose, galactose and glucose+galactose (1:1 were 2.57 ± 0.04, 4.12 ± 0.06 and 3.22 ± 0.05 mg L-1 d-1, respectively. Results show a statistical difference that was found between carbohydrate productivity values expressed as glucose, galactose and glucose+galactose (1:1.

  16. Understanding shape and morphology of unusual tubular starch nanocrystals.

    Science.gov (United States)

    Gong, Bei; Liu, Wenxia; Tan, Hua; Yu, Dehai; Song, Zhaoping; Lucia, Lucian A

    2016-10-20

    Starch nanocrystals (SNC) are aptly described as the insoluble degradation byproducts of starch granules that purportedly display morphologies that are platelet-like, round, square, and oval-like. In this work, we reported the preparation of SNC with unprecedented tubular structures through sulfuric acid hydrolysis of normal maize starch, subsequent exposure to ammonia and relaxation at 4°C. High-resolution transmission electron microscopy observation clearly proved that the SNCs possess tubular nanostructures with polygonal cross-section. After further reviewing the transformations of SNC by acid hydrolysis, ammonia treatment, and curing time at 4°C, a mechanism for T-SNC formation is suggested. It is conjectured that T-SNC gradually self-assembles by combination of smaller platelet-like/square nanocrystals likely loosely aggregated by starch molecular chains from residual amorphous regions. This work paves the way for the pursuit of new approaches for the preparation of starch-based nanomaterials possessing unique morphologies. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Dynamic modeling of temperature change in outdoor operated tubular photobioreactors.

    Science.gov (United States)

    Androga, Dominic Deo; Uyar, Basar; Koku, Harun; Eroglu, Inci

    2017-07-01

    In this study, a one-dimensional transient model was developed to analyze the temperature variation of tubular photobioreactors operated outdoors and the validity of the model was tested by comparing the predictions of the model with the experimental data. The model included the effects of convection and radiative heat exchange on the reactor temperature throughout the day. The temperatures in the reactors increased with increasing solar radiation and air temperatures, and the predicted reactor temperatures corresponded well to the measured experimental values. The heat transferred to the reactor was mainly through radiation: the radiative heat absorbed by the reactor medium, ground radiation, air radiation, and solar (direct and diffuse) radiation, while heat loss was mainly through the heat transfer to the cooling water and forced convection. The amount of heat transferred by reflected radiation and metabolic activities of the bacteria and pump work was negligible. Counter-current cooling was more effective in controlling reactor temperature than co-current cooling. The model developed identifies major heat transfer mechanisms in outdoor operated tubular photobioreactors, and accurately predicts temperature changes in these systems. This is useful in determining cooling duty under transient conditions and scaling up photobioreactors. The photobioreactor design and the thermal modeling were carried out and experimental results obtained for the case study of photofermentative hydrogen production by Rhodobacter capsulatus, but the approach is applicable to photobiological systems that are to be operated under outdoor conditions with significant cooling demands.

  18. Additive manufacturing of patient-specific tubular continuum manipulators

    Science.gov (United States)

    Amanov, Ernar; Nguyen, Thien-Dang; Burgner-Kahrs, Jessica

    2015-03-01

    Tubular continuum robots, which are composed of multiple concentric, precurved, elastic tubes, provide more dexterity than traditional surgical instruments at the same diameter. The tubes can be precurved such that the resulting manipulator fulfills surgical task requirements. Up to now the only material used for the component tubes of those manipulators is NiTi, a super-elastic shape-memory alloy of nickel and titan. NiTi is a cost-intensive material and fabrication processes are complex, requiring (proprietary) technology, e.g. for shape setting. In this paper, we evaluate component tubes made of 3 different thermoplastic materials (PLA, PCL and nylon) using fused filament fabrication technology (3D printing). This enables quick and cost-effective production of custom, patient-specific continuum manipulators, produced on site on demand. Stress-strain and deformation characteristics are evaluated experimentally for 16 fabricated tubes of each thermoplastic with diameters and shapes equivalent to those of NiTi tubes. Tubes made of PCL and nylon exhibit properties comparable to those made of NiTi. We further demonstrate a tubular continuum manipulator composed of 3 nylon tubes in a transnasal, transsphenoidal skull base surgery scenario in vitro.

  19. Radiologic findings of tubular adenoma of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Mi Gyoung; Oh, Ki Keun [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-10-01

    Tubular adenoma (TA) is known as a rare lesion of the breast which is difficult to diagnosis preoperatively because of its rarity and similarity to fibroadenoma. Hence, our purpose is to suggest the characteristic sonographic features for its correct diagnosis. We retrospectively analyzed the clinical data and mammographic and sonographic findings. of seven patients(mean age, 23) who during the previous five years had presented at our hospital with pathologically-proven tubular adenoma. TA was misdiagnosed as fibroadenoma, since on physical examination of these young females, the lesions presented a palpable, non-tender mass. Mammographically, they showed a well defined mass similar to fibroadenoma. However, sonographic findings were characteristic of TA and compared to fibroadenoma, showed a well demarcated and smooth bordered mass with transverse long axis, posterior enhancement and homogeneous lower internal echogenecity. No case showed lateral wall refractive shadowing. In young females, the clinical and mammographic findings of TA are similar to those of fibroadenoma. However, sonographic findings of TA can, be helpful in the differential diagnosis of this entity and fibroadenoma.

  20. Nano-tubular cellulose for bioprocess technology development.

    Directory of Open Access Journals (Sweden)

    Athanasios A Koutinas

    Full Text Available Delignified cellulosic material has shown a significant promotional effect on the alcoholic fermentation as yeast immobilization support. However, its potential for further biotechnological development is unexploited. This study reports the characterization of this tubular/porous cellulosic material, which was done by SEM, porosimetry and X-ray powder diffractometry. The results showed that the structure of nano-tubular cellulose (NC justifies its suitability for use in "cold pasteurization" processes and its promoting activity in bioprocessing (fermentation. The last was explained by a glucose pump theory. Also, it was demonstrated that crystallization of viscous invert sugar solutions during freeze drying could not be otherwise achieved unless NC was present. This effect as well as the feasibility of extremely low temperature fermentation are due to reduction of the activation energy, and have facilitated the development of technologies such as wine fermentations at home scale (in a domestic refrigerator. Moreover, NC may lead to new perspectives in research such as the development of new composites, templates for cylindrical nano-particles, etc.

  1. Radiologic findings of tubular adenoma of the breast

    International Nuclear Information System (INIS)

    Jeong, Mi Gyoung; Oh, Ki Keun

    1996-01-01

    Tubular adenoma (TA) is known as a rare lesion of the breast which is difficult to diagnosis preoperatively because of its rarity and similarity to fibroadenoma. Hence, our purpose is to suggest the characteristic sonographic features for its correct diagnosis. We retrospectively analyzed the clinical data and mammographic and sonographic findings. of seven patients(mean age, 23) who during the previous five years had presented at our hospital with pathologically-proven tubular adenoma. TA was misdiagnosed as fibroadenoma, since on physical examination of these young females, the lesions presented a palpable, non-tender mass. Mammographically, they showed a well defined mass similar to fibroadenoma. However, sonographic findings were characteristic of TA and compared to fibroadenoma, showed a well demarcated and smooth bordered mass with transverse long axis, posterior enhancement and homogeneous lower internal echogenecity. No case showed lateral wall refractive shadowing. In young females, the clinical and mammographic findings of TA are similar to those of fibroadenoma. However, sonographic findings of TA can, be helpful in the differential diagnosis of this entity and fibroadenoma

  2. DEVELOPMENT OF TECHNICAL DECISIONS FOR HEAT SUPPLY WITH TUBULAR GAS HEATERS

    Directory of Open Access Journals (Sweden)

    IRODOV V. F.

    2017-05-01

    Full Text Available Annotation. Problems formulation. The problem that is solved is the development of autonomous heat supply systems that reduce the capital costs of construction and increase the efficiency of the use of energy resources. One of the ways to solve this problem is the use of tubular gas heaters. For this, it is necessary to develop new technical solutions for heat supply with tubular gas heaters, as well as scientific and methodological support for the development, construction and operation of heat supply systems with tubular gas heaters. Analysis of recent research. Preliminary studies of infrared tubular gas heaters are considered, which were used to heat industrial enterprises with sufficiently high premises. The task was to extend the principles of heat supply by means of tubular heaters for heating air, water and heating medium in relatively low rooms. Goal and tasks. To lay out the development of technical solutions for heat supply with tubular gas heaters, which increase the efficiency and reliability of heat supply systems and extend the use of tubular gas heaters in heat supply. Results. Technical solutions for heat supply with tubular gas heaters have made it possible to extend their applications for heating air, water and heating medium in relatively low rooms. Scientific novelty. New technical solutions for heat supply with tubular gas heaters increase the efficiency of using fuel and energy resources at low capital costs. Practical significance. Technical solutions for heat supply using tubular heaters have the potential for wide application in the heat supply of industrial, public and residential facilities. Conclusions. For two decades, new technical solutions for heat supply with tubular gas heaters have been developed, which increase the efficiency and reliability of heat supply systems and can be widely used for autonomous heating.

  3. Dynamic mechanical properties of straight titanium alloy arch wires.

    Science.gov (United States)

    Kusy, R P; Wilson, T W

    1990-10-01

    Eight straight-wire materials were studied: an orthodontic titanium-molybdenum (Ti-Mo) product, TMA; three orthodontic nickel-titanium (Ni-Ti) products, Nitinol, Titanal, and Orthonol; three prototype alloys, a martensitic, an austenitic, and a biphasic alloy; and a hybrid shape-memory-effect product, Biometal. Each wire was prepared with a length-to-cross-sectional area of at least 3600 cm-1. With an Autovibron Model DDV-II-C used in the tensile mode, each sample was scanned from -120 to +200 degrees C at 2 degrees C/min. From the data base, plots of the log storage modulus, log tan delta, and percent change in length vs. temperature were generated. Results showed that the dynamic mechanical properties of the alloys within this TI system are quite different. The Ti-Mo alloy, TMA, was invariant with temperature, having a modulus of 7.30 x 10(11) dyne/cm2 (10.6 x 10(6) psi). The three cold-worked alloys--Nitinol, Titanal, and Orthonol--appeared to be similar, having a modulus of 5.74 x 10(11) dyne/cm2 (8.32 x 10(6) psi). The biphasic shape-memory alloy displayed a phase transformation near ambient temperature; whereas the hybrid shape-memory product, Biometal, underwent a 3-5% change in length during its transformation between 95 and 125 degrees C. Among the Ni-Ti wires tested, several different types of alloys were represented by this intermetallic material.

  4. Straight velocity boundaries in the lattice Boltzmann method

    Science.gov (United States)

    Latt, Jonas; Chopard, Bastien; Malaspinas, Orestis; Deville, Michel; Michler, Andreas

    2008-05-01

    Various ways of implementing boundary conditions for the numerical solution of the Navier-Stokes equations by a lattice Boltzmann method are discussed. Five commonly adopted approaches are reviewed, analyzed, and compared, including local and nonlocal methods. The discussion is restricted to velocity Dirichlet boundary conditions, and to straight on-lattice boundaries which are aligned with the horizontal and vertical lattice directions. The boundary conditions are first inspected analytically by applying systematically the results of a multiscale analysis to boundary nodes. This procedure makes it possible to compare boundary conditions on an equal footing, although they were originally derived from very different principles. It is concluded that all five boundary conditions exhibit second-order accuracy, consistent with the accuracy of the lattice Boltzmann method. The five methods are then compared numerically for accuracy and stability through benchmarks of two-dimensional and three-dimensional flows. None of the methods is found to be throughout superior to the others. Instead, the choice of a best boundary condition depends on the flow geometry, and on the desired trade-off between accuracy and stability. From the findings of the benchmarks, the boundary conditions can be classified into two major groups. The first group comprehends boundary conditions that preserve the information streaming from the bulk into boundary nodes and complete the missing information through closure relations. Boundary conditions in this group are found to be exceptionally accurate at low Reynolds number. Boundary conditions of the second group replace all variables on boundary nodes by new values. They exhibit generally much better numerical stability and are therefore dedicated for use in high Reynolds number flows.

  5. Low Horizontal Beta Function In Long Straights Of The NSLS-II Lattice

    International Nuclear Information System (INIS)

    Fanglei, L.; Bengtsson, J.; Guo, W.; Krinsky, S.; Li, Y.; Yang, L.

    2011-01-01

    The NSLS-II storage ring lattice is comprised of 30 DBA cells arranged in 15 superperiods. There are 15 long straight sections (9.3m) for injection, RF and insertion devices and 15 short straights (6.6m) for insertion devices. In the baseline lattice, the short straights have small horizontal and vertical beta functions but the long straights have large horizontal beta function optimized for injection. In this paper, we explore the possibility of maintaining three long straights with large horizontal beta function while providing the other 12 long straights with smaller horizontal beta function to optimize the brightness of insertion devices. Our study considers the possible linear lattice solutions as well as characterizing the nonlinear dynamics. Results are reported on optimization of dynamic aperture required for good injection efficiency and adequate Touschek lifetime. This paper discusses dynamic aperture optimization for the NSLS-II lattice with alternate high and low horizontal beta function in the long straights, which is proposed for the optimization of the brightness of insertion devices. The linear optics is optimized to meet the requirements of lattice function and source properties. Nonlinear optimization for a lattice with working point at (37.18, 16.2) is performed. Considering the realistic magnets errors and physical apertures, we calculate the frequency maps and plot the tune footprint. The results show that the lattice with high-low beta function has adequate dynamic aperture for good injection efficiency and sufficient Touschek lifetime.

  6. Ratcheting failure of pressurised straight pipes and elbows under reversed bending

    International Nuclear Information System (INIS)

    Vishnuvardhan, S.; Raghava, G.; Gandhi, P.; Saravanan, M.; Goyal, Sumit; Arora, Punit; Gupta, Suneel K.; Bhasin, Vivek

    2013-01-01

    Ratcheting studies were carried out on Type 304LN stainless steel straight pipes and elbows subjected to steady internal pressure and cyclic bending load. The internal pressure for all the straight pipes was 35 MPa and in the case of elbows the internal pressure was varied for different elbows, ranging from 27.6 MPa to 39.2 MPa. Cyclic bending load was applied on the specimens by subjecting them to different levels of load-line displacement. The specimens have undergone significant ratchet swelling (ballooning), ovalization and consequent thinning of the cross-section during ratcheting. The straight pipes failed either by occurrence of through-wall crack accompanied by simultaneous ballooning, or bursting with simultaneous ballooning. All the elbows failed by occurrence of through-wall crack accompanied by simultaneous ballooning. Ratcheting behaviour of straight pipes and elbows were compared and it was generally inferred that ratcheting was more pronounced in straight pipes than in elbows. -- Graphical abstract: Strain history for the specimen QCE-RAT-6-L1. Highlights: • Studies were carried out under combined internal pressure and cyclic bending. • Ratcheting strains were measured at critical locations of the specimens. • Quantified the percentage of ballooning, ovalization and reduction in thickness. • Modes of ratcheting failure of straight pipes and elbows are studied. • Inferred that ratcheting is more pronounced in straight pipes than in elbows

  7. Intubation of prehospital patients with curved laryngoscope blade is more successful than with straight blade.

    Science.gov (United States)

    Alter, Scott M; Haim, Eithan D; Sullivan, Alex H; Clayton, Lisa M

    2018-02-17

    Direct laryngoscopy can be performed using curved or straight blades, and providers usually choose the blade they are most comfortable with. However, curved blades are anecdotally thought of as easier to use than straight blades. We seek to compare intubation success rates of paramedics using curved versus straight blades. Design: retrospective chart review. hospital-based suburban ALS service with 20,000 annual calls. prehospital patients with any direct laryngoscopy intubation attempt over almost 9years. First attempt and overall success rates were calculated for attempts with curved and straight blades. Differences between the groups were calculated. 2299 patients were intubated by direct laryngoscopy. 1865 had attempts with a curved blade, 367 had attempts with a straight blade, and 67 had attempts with both. Baseline characteristics were similar between groups. First attempt success was 86% with a curved blade and 73% with a straight blade: a difference of 13% (95% CI: 9-17). Overall success was 96% with a curved blade and 81% with a straight blade: a difference of 15% (95% CI: 12-18). There was an average of 1.11 intubation attempts per patient with a curved blade and 1.13 attempts per patient with a straight blade (2% difference, 95% CI: -3-7). Our study found a significant difference in intubation success rates between laryngoscope blade types. Curved blades had higher first attempt and overall success rates when compared to straight blades. Paramedics should consider selecting a curved blade as their tool of choice to potentially improve intubation success. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Effect of section shape on frequencies of natural oscillations of tubular springs

    Science.gov (United States)

    Pirogov, S. P.; Chuba, A. Yu; Cherentsov, D. A.

    2018-05-01

    The necessity of determining the frequencies of natural oscillations of manometric tubular springs is substantiated. Based on the mathematical model and computer program, numerical experiments were performed that allowed us to reveal the effect of geometric parameters on the frequencies of free oscillations of manometric tubular springs.

  9. On Energy Balance and Production Costs in Tubular and Flat Panel Photobioreactors

    NARCIS (Netherlands)

    Norsker, N.H.; Barbosa, M.J.; Vermue, M.H.; Wijffels, R.H.

    2012-01-01

    Reducing mixing in both flat panel and tubular photobioreactors can result in a positive net energy balance with state-of-the-art technology and Dutch weather conditions. In the tubular photobioreactor, the net energy balance becomes positive at velocities <0.3 ms-1, at which point the biomass

  10. 78 FR 77421 - Certain Oil Country Tubular Goods From India: Preliminary Affirmative Countervailing Duty...

    Science.gov (United States)

    2013-12-23

    ..., Saudi Arabia, Taiwan, Thailand, the Republic of Turkey, Ukraine, and the Socialist Republic of Vietnam... DEPARTMENT OF COMMERCE International Trade Administration [C-533-858] Certain Oil Country Tubular... producers and exporters of certain oil tubular goods (OCTG) from India. The period of investigation is...

  11. 78 FR 77420 - Certain Oil Country Tubular Goods From the Republic of Turkey: Preliminary Negative...

    Science.gov (United States)

    2013-12-23

    ..., the Republic of the Philippines, Saudi Arabia, Taiwan, Thailand, the Republic of Turkey, Ukraine, and... DEPARTMENT OF COMMERCE International Trade Administration [C-489-817] Certain Oil Country Tubular... provided to producers and exporters of certain oil tubular goods (OCTG) from the Republic of Turkey (Turkey...

  12. Gamma flux responsive self-powered detector with a tubular emitter

    International Nuclear Information System (INIS)

    Goldstein, N.P.; Todt, W.H.

    1982-01-01

    A gamma-sensitive flux detector comprises tubular emitter, an insulating core within the emitter and an insulating layer about the emitter, and a tubular conductive collector electrode about the insulating layer. The emitter material may be platinum, lead, bismuth, tantalum, tungsten; platinum preferred

  13. Tubular Carcinoma of the Breast: Advantages and Limitations of Breast Tomosynthesis

    Directory of Open Access Journals (Sweden)

    Filipa Vilaverde

    2016-01-01

    Full Text Available Tubular carcinoma of the breast is a rare variant of invasive ductal carcinoma. We report a case of 42-year-old asymptomatic female with a histopathological proven multifocal tubular carcinoma, studied by mammography, Tomosynthesis, Ultrasound, and Magnetic Resonance. Herein, we discuss the advantages and limitations of Tomosynthesis, an emerging imaging technique, in this particular case.

  14. Tubular lysosome morphology and distribution within macrophages depend on the integrity of cytoplasmic microtubules

    International Nuclear Information System (INIS)

    Swanson, J.; Bushnell, A.; Silverstein, S.C.

    1987-01-01

    Pinocytosis of the fluorescent dye lucifer yellow labels elongated, membrane-bound tubular organelles in several cell types, including cultured human monocytes, thioglycolate-elicited mouse peritoneal macrophages, and the macrophage-like cell line J774.2. These tubular structures can be identified as lysosomes by acid phosphatase histochemistry and immunofluorescence localization of cathepsin L. The abundance of tubular lysosomes is markedly increased by treatment with phorbol 12-myristate 13-acetate. When labeled by pinocytosis of microperoxidase and examined by electron microscopic histochemistry, the tubular lysosomes have an outside diameter of ≅ 75 nm and a length of several micrometers; they radiate from the cell's centrosphere in alignment with cytoplasmic microtubules and intermediate filaments. Incubation of phorbol myristate acetate-treated macrophages at 4 0 C or in medium containing 5 μM colchicine or nocodazole at 37 0 C leads to disassembly of microtubules and fragmentation of the tubular lysosomes. Return of the cultures to 37 0 C or removal of nocodazole from the medium leads to reassembly of microtubules and the reappearance of tubular lysosomes within 10-20 min. The authors conclude that microtubules are essential for the maintenance of tubular lysosome morphology and that, in macrophages, a significant proportion of the lysosomal compartment is contained within these tubular structures

  15. 76 FR 39071 - Certain Oil Country Tubular Goods From the People's Republic of China: Rescission of...

    Science.gov (United States)

    2011-07-05

    ... DEPARTMENT OF COMMERCE International Trade Administration [C-570-944] Certain Oil Country Tubular... administrative review of the countervailing duty order on certain oil country tubular goods (``OCTG'') from the... subject to administrative protective order (``APO'') of their responsibility concerning the disposition of...

  16. Tubular Carcinoma of the Breast: Advantages and Limitations of Breast Tomosynthesis

    Science.gov (United States)

    Rocha, Ana; Reis, Alcinda

    2016-01-01

    Tubular carcinoma of the breast is a rare variant of invasive ductal carcinoma. We report a case of 42-year-old asymptomatic female with a histopathological proven multifocal tubular carcinoma, studied by mammography, Tomosynthesis, Ultrasound, and Magnetic Resonance. Herein, we discuss the advantages and limitations of Tomosynthesis, an emerging imaging technique, in this particular case. PMID:28116205

  17. Compressibility effects in packed and open tubular gas and supercritical fluid chromatography

    NARCIS (Netherlands)

    Janssen, J.G.M.; Snijders, H.M.J.; Cramers, C.A.; Schoenmakers, P.J.

    1992-01-01

    The influence of the pressure drop on the efficiency and speed of anal. in packed and open tubular supercrit. fluid chromatog. (SFC) is described: methods previously developed to describe the effects of mobile phase compressibility on the performance of open tubular columns in SFC have been extended

  18. PENGURANGAN KADAR CO2 MENGGUNAKAN SPIRULINA PLATENSIS DALAM TUBULAR BIOREACTOR

    Directory of Open Access Journals (Sweden)

    Zainal Syam Arifin

    2015-06-01

    Full Text Available Increasing the population impact on increasing energy demand. On the other hand, the energy generation industry has been blamed as one of the contributors of carbon dioxide about 25% of total CO2 emissions worldwide. Meanwhile, the production of biogas, which aims to address the increasing need of energy, produces carbon dioxide in the range of 25–50% by volume. To overcome this, a cheap method, optimum and efficient as well as environmentally friendly in reducing CO2 levels by using Spirulina platensis is needed. This research aims to created a mathematical models and found the optimum flow rate to reduced levels of CO2 by using Spirulina platensis. This study used a glass tubular bioreactor (D = 2.6 cm at a temperature of 30°C and irradiated with a fluorescent lamp Philips TL 36 Watt, color temperature: 6,200K cool daylight, light output: 2,600 lm, 72 lm/W. Tubular reactor was placed in a box lined with silver foil walls on three sides. With mathematical models of tubular reactor, the reaction rate constants could be predicted. Based on calculations of data and graphs, optimum volumetric velocity could also be predicted. Variation of flowrate to observed the reduction rate of CO2 was 0.25 mL/sec, 0.35 mL/sec, 0.5 mL/sec, 0.75 mL/sec, 1 mL/sec. Carbon source was 99.99% CO2.Observations of Spirulina growth was made on the flow rate of 0.25 mL/sec at the initial levels of dry weight 2.1208 g/L. The results of this study indicated that the low flowratewas a more effective way to reduced carbon dioxide levels using Spirulina platensis (= 2.82×10-4 sec-1. The highest conversion was obtained at a volumetric flow rate of 0.25 mL/sec and optimum speeds in the range of 0.3 to 0.4 mL/sec. The rate of incoming CO2 flux should be less than 0.047 mL/cm2.detik. Specific Growth Rate (µ of Spirulina platensis in this study was 2.56×10-2 minute-1.   Keywords: Spirulina platensis, a vertical tubular bioreactor, CO2 reduction     ABSTRAK

  19. Transmission of fast highly charged ions through straight and tapered glass capillaries

    International Nuclear Information System (INIS)

    Ayyad, Asma M; Keerthisinghe, D; Kayani, A; Tanis, J A; Dassanayake, B S; Ikeda, T

    2013-01-01

    The transmission of 1 and 3 MeV protons through a borosilicate straight glass capillary and a tapered glass capillary was investigated. The straight capillary had a diameter of ∼0.18 mm and a length of ∼14.4 mm, while the tapered capillary had an inlet diameter of ∼0.71 mm, an outlet diameter of ∼0.10 mm and a length of ∼28 mm. The results show that the 1 and 3 MeV protons traverse through both samples without energy loss, while the tapered capillary showed better transmission than the straight capillary. (paper)

  20. Simulation and analysis of the transmission properties of curved-straight neutron guide systems

    International Nuclear Information System (INIS)

    Copley, J.R.D.; Mildner, D.F.R.

    1992-01-01

    This paper reports that the spatial intensity distribution of neutrons emerging from a curved guide is far from uniform, particularly at short wavelengths, and curved guides are sometimes followed by a straight section of guide to make the intensity distribution more uniform. The behavior of neutrons within curved-straight neutron guide systems is examined using both ray-tracing and analytical approaches to the problem. The intensity distribution within the straight guide tends to wash from one side of the guide to the other. The amplitude of this transverse wave decreases with increasing guide length, and the characteristic length of the wave decreases with increasing neutron wavelength

  1. [The peculiar morphological features of the imprints of straight and wavy head hair dirtied with blood].

    Science.gov (United States)

    Leonova, E N; Nagornov, M N; Prokhorenko, A S

    2018-01-01

    The objective of the present study was to elucidate the specific morphological features of the imprints of blood-soaked straight and wavy head hair. The contact imprints of straight and wavy head hair dirtied with blood were obtained experimentally. The imprints of straight hair were shown to exhibit the elements in the form of the rectilinear and bow-shaped slightly bent stripes. The imprints of wavy hair were shaped as the arches, waves, circles, and a large number of various small elements, such as dashes and commas.

  2. School Climate, Individual Support, or Both? Gay-Straight Alliances and the Mental Health of Sexual Minority Youth

    Science.gov (United States)

    Walls, N. Eugene; Wisneski, Hope; Kane, Sarah

    2013-01-01

    Using a sample of 284 sexual minority youth and young adults, this paper examines the relationships between mental health variables, the absence or presence of a gay-straight alliance, and membership status in a gay-straight alliance. The results suggest that the presence of a gay-straight alliance in a school or college, rather than actual…

  3. Process for the fixing of a metallic end piece on a tubular component

    International Nuclear Information System (INIS)

    Charpin, Jean.

    1975-01-01

    Under this invention the process makes it possible to joint a tubular component and in particular a tubular filter and an end piece, with a connection of great mechanical strength, perfectly leak proof and with excellent corrosion resistance, particularly with respect to fluorinated by-products. This process is therefore of great worth in fixing to a bearer a thin ceramic compound tubular filter element, since such a filter can be used in particular for the separation of uranium isotopes by gaseous diffusion and for the separation of hydrocarbons in petrochemicals. To this end, the process under consideration is characterised in that it consists in depositing a layer of ceramic material, by hot projection, at the end of the tubular element and in sealing the end piece to the end of the tubular element by the hot projection of a ceramic or metallic substance [fr

  4. Fabrication of cathode supported tubular solid oxide electrolysis cell for high temperature steam electrolysis

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Le; Wang, Shaorong; Qian, Jiqin; Xue, Yanjie; Liu, Renzhu

    2011-01-15

    In recent years, hydrogen has been identified as a potential alternative fuel and energy carrier for the future energy supply. Water electrolysis is one of the important hydrogen production technologies which do not emit carbon dioxide. High temperature steam electrolysis (HTSE) consumes even less electrical energy than low temperature water electrolysis. Theoretically, HTSE using solid oxide electrolysis cells (SOEC) can efficiently utilize renewable energy to produce hydrogen, and it is also possible to operate the SOEC in reverse mode as the solid oxide fuel cell (SOFC) to produce electricity. Tubular SOFC have been widely investigated. In this study, tubular solid oxide cells were fabricated by dip-coating and cosintering techniques. In SOEC mode, results suggested that steam ratio had a strong impact on the performance of the tubular cell; the tubular SOEC preferred to be operated at high steam ratio in order to avoid concentration polarization. The microstructure of the tubular SOEC should therefore be optimized for high temperature steam electrolysis.

  5. Research on typical topologies of a tubular horizontal-gap passive magnetic levitation vibration isolator

    Directory of Open Access Journals (Sweden)

    Zhou Yiheng

    2017-01-01

    Full Text Available Magnetic levitation vibration isolators have attracted more and more attention in the field of high-precision measuring and machining equipment. In this paper, we describe a tubular horizontal-gap passive magnetic levitation vibration isolator. Four typical topologies of the tubular horizontal-gap passive magnetic levitation vibration isolator are proposed. The analytical expression of magnetic force is derived. The relationship between levitation force, force density, force ripple and major structural parameters are analysed by finite element method, which is conductive to the design and optimization of the tubular horizontal-gap passive magnetic levitation vibration isolator. The force characteristics of different topologies of the tubular horizontal-gap passive magnetic levitation vibration isolator are compared and evaluated from the aspect of force density, force ripple and manufacturability. In comparison with conventional passive magnetic levitation vibration isolators, the proposed tubular horizontal-gap passive magnetic levitation vibration isolator shows advantage in higher force density.

  6. Straight sinus: ultrastructural analysis aimed at surgical tumor resection.

    Science.gov (United States)

    Amato, Marcelo Campos Moraes; Tirapelli, Luis Fernando; Carlotti, Carlos Gilberto; Colli, Benedicto Oscar

    2016-08-01

    OBJECTIVE Accurate knowledge of the anatomy of the straight sinus (SS) is relevant for surgical purposes. During one surgical procedure involving the removal of part of the SS wall, the authors observed that the venous blood flow was maintained in the SS, possibly through a vein-like structure within the dural sinus or dural multiple layers. This observation and its divergence from descriptions of the histological features of the SS walls motivated the present study. The authors aimed to investigate whether it is possible to dissect the SS walls while keeping the lumen intact, and to describe the histological and ultrastructural composition of the SS wall. METHODS A total of 22 cadaveric specimens were used. The SS was divided into three portions: anterior, middle, and posterior. The characteristics of the SS walls were analyzed, and the feasibility of dissecting them while keeping the SS lumen intact was assessed. The thickness and the number of collagen fibers and other tissues in the SS walls were compared with the same variables in other venous sinuses. Masson's trichrome and Verhoeff's stains were used to assess collagen and elastic fibers, respectively. The data were analyzed using Zeiss image analysis software (KS400). RESULTS A vein-like structure independent of the SS walls was found in at least one of the portions of the SS in 8 of 22 samples (36.36%). The inferior wall could be delaminated in at least one portion in 21 of 22 samples (95.45%), whereas the lateral walls could seldom be delaminated. The inferior wall of the SS was thicker (p < 0.05) and exhibited less collagen and greater amounts of other tissues-including elastic fibers, connective tissue, blood vessels, and nerve fibers (p < 0.05)-compared with the lateral walls. Transmission electron microscopy revealed the presence of muscle fibers at a level deeper than that of the subendothelial connective tissue in the inferior wall of the SS, extending from its junction with the great cerebral vein

  7. Longitudinal relaxation of initially straight flexible and stiff polymers

    Science.gov (United States)

    Dimitrakopoulos, Panagiotis; Dissanayake, Inuka

    2004-11-01

    The present talk considers the relaxation of a single flexible or stiff polymer chain from an initial straight configuration in a viscous solvent. This problem commonly arises when strong flows are turned off in both industrial and biological applications. The problem is also motivated by recent experiments with single biopolymer molecules relaxing after being fully extended by applied forces as well as by the recent development of micro-devices involving stretched tethered biopolymers. Our results are applicable to a wide array of synthetic polymers such as polyacrylamides, Kevlar and polyesters as well as biopolymers such as DNA, actin filaments, microtubules and MTV. In this talk we discuss the mechanism of the polymer relaxation as was revealed through Brownian Dynamics simulations covering a broad range of time scales and chain stiffness. After the short-time free diffusion, the chain's longitudinal reduction at early intermediate times is shown to constitute a universal behavior for any chain stiffness caused by a quasi-steady relaxation of tensions associated with the deforming action of the Brownian forces. Stiff chains are shown to exhibit a late intermediate-time longitudinal reduction associated with a relaxation of tensions affected by the deforming Brownian and the restoring bending forces. The longitudinal and transverse relaxations are shown to obey different laws, i.e. the chain relaxation is anisotropic at all times. In the talk, we show how from the knowledge of the relaxation mechanism, we can predict and explain the polymer properties including the polymer stress and the solution birefringence. In addition, a generalized stress-optic law is derived valid for any time and chain stiffness. All polymer properties which depend on the polymer length are shown to exhibit two intermediate-time behaviors with the early one to constitute a universal behavior for any chain stiffness. This work was supported in part by the Minta Martin Research Fund. The

  8. Renal transplantant blood flow in patients with acute tubular necrosis

    Energy Technology Data Exchange (ETDEWEB)

    Huic, D; Crnkovic, S; Bubic-Filipi, L J; Grosev, D; Dodig, P; Porapat, M; Puretic, Z [Univ. Hospital Rebro, Zagreb (Croatia)

    1997-09-01

    The aim of this study was to investigate the quantity of renal transport blood flow in patients affected by acute tubular necrosis (ATN). During the four years period two hundred and thirty-three studies were performed using {sup 99m}Tc pertechnetate and {sup 131}I - OIH. Renal blood flow was calculated from the first-pass time activity curves generated over the kidney and aorta and expressed as a percentage of cardiac output (RBF/CO). Renal transplant blood flow is clearly diminished in ATN, similar as in acute rejection, and significantly related to the graft function, what means that RBF/CO value could potentially serve as a prognostic factor in the graft function recovery from ATN.

  9. A Phase of Liposomes with Entangled Tubular Vesicles

    Science.gov (United States)

    Chiruvolu, Shivkumar; Warriner, Heidi E.; Naranjo, Edward; Idziak, Stefan H. J.; Radler, Joachim O.; Plano, Robert J.; Zasadzinski, Joseph A.; Safinya, Cyrus R.

    1994-11-01

    An equilibrium phase belonging to the family of bilayer liposomes in ternary mixtures of dimyristoylphosphatidylcholine (DMPC), water, and geraniol (a biological alcohol derived from oil-soluble vitamins that acts as a cosurfactant) has been identified. Electron and optical microscopy reveal the phase, labeled Ltv, to be composed of highly entangled tubular vesicles. In situ x-ray diffraction confirms that the tubule walls are multilamellar with the lipids in the chain-melted state. Macroscopic observations show that the Ltv phase coexists with the well-known L_4 phase of spherical vesicles and a bulk L_α phase. However, the defining characteristic of the Ltv phase is the Weissenberg rod climbing effect under shear, which results from its polymer-like entangled microstructure.

  10. Scavenging energy from human motion with tubular dielectric polymer

    Science.gov (United States)

    Jean-Mistral, Claire; Basrour, Skandar

    2010-04-01

    Scavenging energy from human motion is a challenge to supply low consumption systems for sport or medical applications. A promising solution is to use electroactive polymers and especially dielectric polymers to scavenge mechanical energy during walk. In this paper, we present a tubular dielectric generator which is the first step toward an integration of these structures into textiles. For a 10cm length and under a strain of 100%, the structure is able to scavenge 1.5μJ for a poling voltage of 200V and up to 40μJ for a poling voltage of 1000V. A 30cm length structure is finally compared to our previous planar structure, and the power management module for those structures is discussed.

  11. Thermal characteristics of tubular receivers of solar radiation line concentrators

    International Nuclear Information System (INIS)

    Klychev, Sh.I.; Zakhidov, R.A.; Khuzhanov, R. et al.

    2013-01-01

    A stationary thermal model of an LCS-HR system is considered, taking into account the basic parameters of the problem: availability of a transparent screen, selectivity of the receiver, characteristics of the heat carrier and average concentration on the surface of the tubular receiver C"". Based on this model, an algorithm and program of numerical research of the thermal characteristics of the HR-temperature of heating and local and average coefficients of efficiency are developed. For possible concentrations, the selectivity of the receiver and the transparency of the screen in linear concentrators, the potential stationary heating temperatures, and the coefficients of efficiency for main three types of heat carriers - air, water, and liquid metal coolant are studied. The time of achieving stationary values by the temperatures of the heat carrier is estimated. (author)

  12. Amelogenesis Imperfecta with Distal Renal Tubular Acidosis: A Novel Syndrome?

    Science.gov (United States)

    Misgar, R A; Hassan, Z; Wani, A I; Bashir, M I

    2017-01-01

    Amelogenesis imperfecta (AI) is a heterogeneous group of inherited dental enamel defects. It has rarely been reported in association with multiorgan syndromes and metabolic disorders. The metabolic disorders that have been reported in association with AI include hypocalciuria, impaired urinary concentrating ability, and Bartter-like syndrome. In literature, only three cases of AI and distal renal tubular acidosis (dRTA) have been described: two cases in adults and a solitary case in the pediatric age group. Here, we report a child with AI presenting with dRTA; to the best of our knowledge, our reported case is the only second such case in pediatric age group. Our case highlights the importance of recognizing the possibility of renal abnormalities in patients with AI as it will affect the long-term prognosis.

  13. Amelogenesis imperfecta with distal renal tubular acidosis: A novel syndrome?

    Directory of Open Access Journals (Sweden)

    R A Misgar

    2017-01-01

    Full Text Available Amelogenesis imperfecta (AI is a heterogeneous group of inherited dental enamel defects. It has rarely been reported in association with multiorgan syndromes and metabolic disorders. The metabolic disorders that have been reported in association with AI include hypocalciuria, impaired urinary concentrating ability, and Bartter-like syndrome. In literature, only three cases of AI and distal renal tubular acidosis (dRTA have been described: two cases in adults and a solitary case in the pediatric age group. Here, we report a child with AI presenting with dRTA; to the best of our knowledge, our reported case is the only second such case in pediatric age group. Our case highlights the importance of recognizing the possibility of renal abnormalities in patients with AI as it will affect the long-term prognosis.

  14. Tubular Scaffold with Shape Recovery Effect for Cell Guide Applications

    Directory of Open Access Journals (Sweden)

    Kazi M. Zakir Hossain

    2015-07-01

    Full Text Available Tubular scaffolds with aligned polylactic acid (PLA fibres were fabricated for cell guide applications by immersing rolled PLA fibre mats into a polyvinyl acetate (PVAc solution to bind the mats. The PVAc solution was also mixed with up to 30 wt % β-tricalcium phosphate (β-TCP content. Cross-sectional images of the scaffold materials obtained via scanning electron microscopy (SEM revealed the aligned fibre morphology along with a significant number of voids in between the bundles of fibres. The addition of β-TCP into the scaffolds played an important role in increasing the void content from 17.1% to 25.3% for the 30 wt % β-TCP loading, which was measured via micro-CT (µCT analysis. Furthermore, µCT analyses revealed the distribution of aggregated β-TCP particles in between the various PLA fibre layers of the scaffold. The compressive modulus properties of the scaffolds increased from 66 MPa to 83 MPa and the compressive strength properties decreased from 67 MPa to 41 MPa for the 30 wt % β-TCP content scaffold. The scaffolds produced were observed to change into a soft and flexible form which demonstrated shape recovery properties after immersion in phosphate buffered saline (PBS media at 37 °C for 24 h. The cytocompatibility studies (using MG-63 human osteosarcoma cell line revealed preferential cell proliferation along the longitudinal direction of the fibres as compared to the control tissue culture plastic. The manufacturing process highlighted above reveals a simple process for inducing controlled cell alignment and varying porosity features within tubular scaffolds for potential tissue engineering applications.

  15. Numerical Simulation of Tubular Pumping Systems with Different Regulation Methods

    Science.gov (United States)

    Zhu, Honggeng; Zhang, Rentian; Deng, Dongsheng; Feng, Xusong; Yao, Linbi

    2010-06-01

    Since the flow in tubular pumping systems is basically along axial direction and passes symmetrically through the impeller, most satisfying the basic hypotheses in the design of impeller and having higher pumping system efficiency in comparison with vertical pumping system, they are being widely applied to low-head pumping engineering. In a pumping station, the fluctuation of water levels in the sump and discharge pool is most common and at most time the pumping system runs under off-design conditions. Hence, the operation of pump has to be flexibly regulated to meet the needs of flow rates, and the selection of regulation method is as important as that of pump to reduce operation cost and achieve economic operation. In this paper, the three dimensional time-averaged Navier-Stokes equations are closed by RNG κ-ɛ turbulent model, and two tubular pumping systems with different regulation methods, equipped with the same pump model but with different designed system structures, are numerically simulated respectively to predict the pumping system performances and analyze the influence of regulation device and help designers make final decision in the selection of design schemes. The computed results indicate that the pumping system with blade-adjusting device needs longer suction box, and the increased hydraulic loss will lower the pumping system efficiency in the order of 1.5%. The pumping system with permanent magnet motor, by means of variable speed regulation, obtains higher system efficiency partly for shorter suction box and partly for different structure design. Nowadays, the varied speed regulation is realized by varied frequency device, the energy consumption of which is about 3˜4% of output power of the motor. Hence, when the efficiency of variable frequency device is considered, the total pumping system efficiency will probably be lower.

  16. 49 CFR 238.119 - Rim-stamped straight-plate wheels.

    Science.gov (United States)

    2010-10-01

    ... input to the wheel during braking. (b) A rim-stamped straight-plate wheel shall not be used as a... that is periodically tread-braked for a short duration by automatic circuitry for the sole purpose of...

  17. Ring energy selection and extra long straight sections for the Advanced Photon Source

    International Nuclear Information System (INIS)

    1987-04-01

    Recommended criteria are given for the performance of Advanced Photon Source (APS), taking into consideration undulator tunability criteria and their relationship to the storage ring energy and undulator gap, length of straight sections

  18. Manufacture of the straight section chambers for the SPring-8 storage ring

    International Nuclear Information System (INIS)

    Watanabe, K.; Saeki, H.; Sakaue, H.; Ohkuma, H.; Be, S.H.; Oishi, M.; Tuchiya, M.; Nishidono, T.

    1995-01-01

    To carry out the performance test of the vacuum system, we manufactured three different straight section chambers prior to the manufacture of the 48 cell full scale vacuum systems. One of three straight section chambers contains only downstream end absorber, while the other two contain a downstream end absorber, upstream end bellows and a photon beam extraction duct. In this paper, the manufacture of these chambers and their assemblies are described in detail. (author). 1 ref., 3 figs., 3 tabs

  19. Friends with benefits, but without the sex: straight women and gay men exchange trustworthy mating advice.

    Science.gov (United States)

    Russell, Eric M; DelPriore, Danielle J; Butterfield, Max E; Hill, Sarah E

    2013-02-09

    Although research has made progress in elucidating the benefits exchanged within same- and opposite-sex friendships formed between heterosexual men and women, it is less clear why straight women and gay men form close relationships with one another. The current experiments begin to address this question by exploring a potential benefit hypothesized to be uniquely available to straight women and gay men in the context of these friendships: trustworthy mating advice. Experiment 1 revealed that straight women perceive mating-relevant advice from a gay man to be more trustworthy than similar advice offered by a straight man or woman. Experiment 2 demonstrated that gay men perceive mating advice offered by a straight woman to be more trustworthy than advice offered by a lesbian woman or another gay man. Overall, the results provide initial experimental evidence that relationships between gay men and straight women may be characterized by a mutual exchange of mating-relevant benefits in the absence of sexual interest or competition.

  20. Efficient odd straight medium chain free fatty acid production by metabolically engineered Escherichia coli.

    Science.gov (United States)

    Wu, Hui; San, Ka-Yiu

    2014-11-01

    Free fatty acids (FFAs) can be used as precursors for the production of biofuels or chemicals. Different composition of FFAs will be useful for further modification of the biofuel/biochemical quality. Microbial biosynthesis of even chain FFAs can be achieved by introducing an acyl-acyl carrier protein thioesterase gene into E. coli. In this study, odd straight medium chain FFAs production was investigated by using metabolic engineered E. coli carrying acyl-ACP thioesterase (TE, Ricinus communis), propionyl-CoA synthase (Salmonella enterica), and β-ketoacyl-acyl carrier protein synthase III (four different sources) with supplement of extracellular propionate. By using these metabolically engineered E. coli, significant quantity of C13 and C15 odd straight-chain FFAs could be produced from glucose and propionate. The highest concentration of total odd straight chain FFAs attained was 1205 mg/L by the strain HWK201 (pXZ18, pBHE2), and 85% of the odd straight chain FFAs was C15. However, the highest percentage of odd straight chain FFAs was achieved by the strain HWK201 (pXZ18, pBHE3) of 83.2% at 48 h. This strategy was also applied successfully in strains carrying different TE, such as the medium length acyl-ACP thioesterase gene from Umbellularia californica. C11 and C13 became the major odd straight-chain FFAs. © 2014 Wiley Periodicals, Inc.

  1. Friends with Benefits, but without the Sex: Straight Women and Gay Men Exchange Trustworthy Mating Advice

    Directory of Open Access Journals (Sweden)

    Eric M. Russell

    2013-01-01

    Full Text Available Although research has made progress in elucidating the benefits exchanged within same- and opposite-sex friendships formed between heterosexual men and women, it is less clear why straight women and gay men form close relationships with one another. The current experiments begin to address this question by exploring a potential benefit hypothesized to be uniquely available to straight women and gay men in the context of these friendships: trustworthy mating advice. Experiment 1 revealed that straight women perceive mating-relevant advice from a gay man to be more trustworthy than similar advice offered by a straight man or woman. Experiment 2 demonstrated that gay men perceive mating advice offered by a straight woman to be more trustworthy than advice offered by a lesbian woman or another gay man. Overall, the results provide initial experimental evidence that relationships between gay men and straight women may be characterized by a mutual exchange of mating-relevant benefits in the absence of sexual interest or competition.

  2. Comparison of 21G curved and straight phacotips designs in transversal microcoaxial phacoemulsification

    Directory of Open Access Journals (Sweden)

    Süleyman Demircan

    2015-12-01

    Full Text Available AIM:To compare the intraoperative performance and postoperative outcomes after microcoaxial torsional phacoemulsification using the straight and the curved phacotip configurations.METHODS:Cataracts were treated using 2.2mm microcoaxial transversal phacoemulsification with either a 30°straight or 30° curved phaco tip. Intraoperative measurements analyzed included the average ultrasound(U/Spower, the total phacoemulsification time, and the effective phacoemulsification time(EPT. The central endothelial cell density(ECDand the central corneal thickness(CCTwere evaluated preoperatively and postoperatively at 1, 7 and 30d after surgery using noncontact specular microscopy. RESULTS:The study enrolled a total of 190 eyes(190 patients, 95 eyes in the curved tip group and 95 eyes in straight tip group. Intraoperative measurements showed significantly reduced total phacoemulsification time, and EPT in the curved-tip group, compared to the straight-tip group(Pst-3rd quartilesand 18.0(9.0-30.0s in curved-tip group, and 38.8(16.5-73.5s and 26.0(11.0-49.0s in the straight-tip group, respectively. CONCLUSION:Transversal phacoemulsification performed with a curved tip provided more effective lens removal with a less total UST and EPT in all grades, except for grades IV, compared to a straight tip.

  3. VALIDATION OF SIMULATION MODELS FOR DIFFERENTLY DESIGNED HEAT-PIPE EVACUATED TUBULAR COLLECTORS

    DEFF Research Database (Denmark)

    Fan, Jianhua; Dragsted, Janne; Furbo, Simon

    2007-01-01

    Differently designed heat-pipe evacuated tubular collectors have been investigated theoretically and experimentally. The theoretical work has included development of two TRNSYS [1] simulation models for heat-pipe evacuated tubular collectors utilizing solar radiation from all directions. One model...... coating on both sides. The input to the models is thus not a simple collector efficiency expression but the actual collector geometry. In this study, the TRNSYS models are validated with measurements for four differently designed heat-pipe evacuated tubular collectors. The collectors are produced...

  4. Undulating tubular liposomes through incorporation of a synthetic skin ceramide into phospholipid bilayers.

    Science.gov (United States)

    Xu, Peng; Tan, Grace; Zhou, Jia; He, Jibao; Lawson, Louise B; McPherson, Gary L; John, Vijay T

    2009-09-15

    Nonspherical liposomes were prepared by doping L-alpha-phosphatidylcholine (PC) with ceramide VI (a skin lipid). Cryo-transmission electron microscopy shows the liposome shape changing from spherical to an undulating tubular morphology, when the amount of ceramide VI is increased. The formation of tubular liposomes is energetically favorable and is attributed to the association of ceramide VI with PC creating regions of lower curvature. Since ceramides are the major component of skin lipids in the stratum corneum, tubular liposomes containing ceramide may potentially serve as self-enhanced nanocarriers for transdermal delivery.

  5. Additional Quadrupoles At Center Of Long Straights In The NSLS-II Lattice

    International Nuclear Information System (INIS)

    Lin, F.; Bengtsson, J.; Guo, W.; Krinsky, S.; Li, Y.; Yang, L.

    2011-01-01

    The NSLS-II storage ring lattice is comprised of 30 DBA cells arranged in 15 superperiods. There are 15 long straight sections (9.3m) for injection, RF and insertion devices and 15 shorter straights (6.6m) for insertion devices. In the baseline lattice, the short straights have small horizontal and vertical beta functions but the long straights have large horizontal beta function optimized for injection. In this paper, we explore the possibility of installing additional quadrupoles at the center of selected long straight sections in order to provide two low-beta source locations for undulators in the same straight. The required modification to the linear lattice is discussed as well as the preservation of adequate dynamic aperture required for good injection efficiency and adequate Touschek lifetime. This paper discusses the possibility of producing two low-beta source locations for optimum brightness of undulators in the long straights of NSLS-II lattice by installing additional quadrupoles at the center. The linear optics is optimized to satisfy the requirements of lattice function and properties. Nonlinear optimization for a lattice with working point at (37.16, 17.22) is performed. Considering the magnets misalignment errors and physical apertures, we calculate the frequency maps and plot the tune footprint. The results show that the modified high-low beta function lattice can achieve a modest dynamic aperture in this preliminary study. Further work will continue to expand the dynamic aperture to meet the requirement of good injection efficiency and sufficient Touschek lifetime.

  6. Biofiksasi CO2 Oleh Mikroalga Chlamydomonas sp dalam Photobioreaktor Tubular

    Directory of Open Access Journals (Sweden)

    Hadiyanto Hadiyanto

    2014-05-01

    Full Text Available Mikroalga memiliki potensi dalam membiofiksasi CO2 dan dapat dimanfaatkan untuk mengurangi kadar CO2 dalam gas pencemar. Pertumbuhan mikroalga sangat dipengaruhi oleh konsentrasi gas CO2 di dalam gas pencemar. Tujuan penelitian ini adalah untuk mengeetahui kemampuan mikroalga Chlamydomonas sp yang dikultivasi dalam photobioreaktor tubular dalam penyerapan gas CO2 serta untuk mengetahui konsentrasi maksimum gas CO2 dalam umpan untuk memproduksi biomasa mikroalga yang optimal. Percobaan dilakukan dnegan memvariasi laju alir dari 0.03 -0.071 L/menit dan konsentrasi CO2 dalam umpan 10-30%. Hasil penelitian menunjukkan bahwa biomasa mikroalga dapat diproduksi dengan maksimal dengan konsentrasi gas CO2 20% dengan laju alir 0.07 L/min. Semakin tinggi laju alir maka produksi biomasa alga semakin besar. Kecepatan pertumbuhan alga maksimum terjadi pada 0.31 /hari. Pada konsentrasi gas CO2 30%, terjadi substrate inhibition yang disebabkan carbon dalam bentuk ion bicarbonate tidak dapat dikonsumsi lagi di dalam kultur alga. Kata kunci : Mikroalga, chlamydomonas sp, biofiksasi CO2, biogas Abstract Microalgae have a potential for CO2 biofixation and therefore can be used to reduce the CO2 concentration in the gas pollutants. Moreover, microalgae growth is strongly affected by the concentration of CO2 in the exhaust gas pollutants. The objective of this research was to investigate the ability of microalgae Chlamydomonas sp which was cultivated in a tubular photobioreactor for CO2 absorption as well as to determine the maximum concentration of CO2 in the feed gas to obtain optimum microalgae biomass. The experiments were performed by varying the gas flow rate of 0.03 -0.071 L / min and the concentration of CO2 in the feed of 10-30%. The results showed that the maximum biomass of microalgae can be produced with CO2 concentration of 20% vol with a flow rate of 0.07 L / min. The result also showed that increasing the gas flow rate, the greater of the production of

  7. Testing of tubular goods - a critical review of past and actual testing procedures

    Energy Technology Data Exchange (ETDEWEB)

    Teodoriu, C. [Texas A and M Univ., Houston, TX (United States); Holzmann, J.; Klaws, M. [TU Clausthal (Germany). Inst. fuer Erdoel- und Erdgastechnik

    2007-09-13

    Testing of oil country tubular goods (OCTG) is based on standards and offers the user a comparison platform between products of different manufacturers. But, do the standard based testing procedures assume the real loads on OCTG? More likely, the existing standards or recommendations on tubular testing have been evolving together with the new demands on OCTG loading. Since nowadays the oil and gas industry is looking to develop extreme reservoir types (deep water, HP/HT), there is a need of a better understanding and continuous improvement of testing procedures. The following poster proposes an analysis of existing procedures to test tubular goods and then will focus on the future demands on OCTG testing. New loads, as casing fatigue, will be discussed and analyzed based on the authors experience gained during more than 8 years of testing tubular goods at the Clausthal University of Technology, Institute of Petroleum Engineering. (orig.)

  8. The Association of Albuminuria With Tubular Reabsorption of Uric Acid : Results From a General Population Cohort

    NARCIS (Netherlands)

    Scheven, Lieneke; Joosten, Michel M.; de Jong, Paul E.; Bakker, Stephan J. L.; Gansevoort, Ron T.

    Background-Elevated albuminuria as well as an increased serum uric acid concentration is associated with poor cardiovascular outcome. We questioned whether these 2 variables (albuminuria and serum uric concentration) may be interrelated via tubular uric acid reabsorption. Methods and

  9. Design, Fabrication and Test of a Full Scale Copper Tubular Combustion Chamber

    National Research Council Canada - National Science Library

    Cooley, Christine

    2002-01-01

    This paper presents the design fabrication and test of a full scale copper tubular combustion chamber as an enabling technology for future application in a high thrust upper-stage expander-cycle engine...

  10. A tubular dielectric elastomer actuator: Fabrication, characterization and active vibration isolation

    DEFF Research Database (Denmark)

    Sarban, R.; Jones, R. W.; Mace, B. R.

    2011-01-01

    This contribution reviews the fabrication, characterization and active vibration isolation performance of a core-free rolled tubular dielectric elastomer (DE) actuator, which has been designed and developed by Danfoss PolyPower A/S. PolyPower DE material, PolyPower (TM), is produced in thin sheets...... of 80 mu m thickness with corrugated metallic electrodes on both sides. Tubular actuators are manufactured by rolling the DE sheets in a cylindrical shape. The electromechanical characteristics of such actuators are modeled based on equilibrium pressure equation. The model is validated with experimental...... the dominant dynamic characteristics of the core-free tubular actuator. It has been observed that all actuators have similar dynamic characteristics in a frequency range up to 1 kHz. A tubular actuator is then used to provide active vibration isolation (AVI) of a 250 g mass subject to shaker generated 'ground...

  11. Large tubular colonic duplication in an adult treated with a small midline incision

    Science.gov (United States)

    Yong, Yuen Geng; Jung, Kyung Uk; Cho, Yong Beom; Yun, Seong Hyeon; Kim, Hee Cheol; Lee, Woo Yong

    2012-01-01

    Tubular colonic duplication presenting in adults is rare and difficult to diagnose preoperatively. Only a few cases have been reported in the literature. We report a case of a 29-year-old lady presenting with a long history of chronic constipation, abdominal mass and repeated episodes of abdominal pain. The abdominal-pelvic computed tomography scan showed segmental bowel wall thickening thought to be small bowel, and dilatation with stasis of intraluminal content. The provisional diagnosis was small bowel duplication. She was scheduled for single port laparoscopic resection. However, a T-shaped tubular colonic duplication at sigmoid colon was found intraoperatively. Resection of the large T-shaped tubular colonic duplication containing multiple impacted large fecaloma and primary anastomosis was performed. There was no perioperative complication. We report, herein, the case of a T-shaped tubular colonic duplication at sigmoid colon in an adult who was successfully treated through mini-laparotomy assisted by single port laparoscopic surgery. PMID:22403754

  12. Muscle imaging in patients with tubular aggregate myopathy caused by mutations in STIM1

    DEFF Research Database (Denmark)

    Tasca, Giorgio; D'Amico, Adele; Monforte, Mauro

    2015-01-01

    Tubular aggregate myopathy is a genetically heterogeneous disease characterized by tubular aggregates as the hallmark on muscle biopsy. Mutations in STIM1 have recently been identified as one genetic cause in a number of tubular aggregate myopathy cases. To characterize the pattern of muscle...... involvement in this disease, upper and lower girdles and lower limbs were imaged in five patients with mutations in STIM1, and the scans were compared with two patients with tubular aggregate myopathy not caused by mutations in STIM1. A common pattern of involvement was found in STIM1-mutated patients...... of thigh and posterior leg with sparing of gracilis, tibialis anterior and, to a lesser extent, short head of biceps femoris. Mutations in STIM1 are associated with a homogeneous involvement on imaging despite variable clinical features. Muscle imaging can be useful in identifying STIM1-mutated patients...

  13. Tubular adenoma of the breast in a pregnant girl: report on a case.

    Science.gov (United States)

    Palnaes Hansen, C; Fahrenkrug, L; Hastrup, N

    1991-12-01

    A rare case of a tubular breast adenoma in a 13-year-old pregnant girl is presented. The tumor which developed during pregnancy measured 10 x 8 x 4 cm, was well demarcated and could be totally removed.

  14. Design, analysis, and test of an active tubular interface

    Science.gov (United States)

    Elspass, Wilfried J.; Eerme, M.; Paradies, R.; Resch, Martin

    1997-06-01

    Space missions require higher and higher performance such as high pointing accuracy and stability, and high shape precision. Passive damping means often cannot fulfill the requirements. Besides space applications at the same time numerous applications in machine design require higher accuracy. For a lot of applications the passive measures come up against limits. Active technologies have to be considered more often. Active mechanical components are more and more used as a necessary step towards adaptive structures. Active mechanical interfaces are simpler systems having very useful applications and can be used as kind of test benches in order to master the most exacting technologies. The main advantages of such an active interface are the following: (1) state-of- the-art sensors and actuators can be used, (2) the mechanical design of the interface is conventional, (3) the passive behavior of the system is not deteriorated, (4) the design is compact and rather easy to integrate, (5) easy repair (replacement) of the active mechanical part, (6) standardization of the interfaces results in cost reductions. An important property in such intermediate step is that no major redesign of the conventionally designed mechanical structure should be needed. The design, numerical analysis, manufacturing and test of a fully integrated active tubular interface (ATI) is presented. The design of the ATI includes the optimal laminate stacking sequence with respect to maximum deformation efficiency. The results of an active damping application, an antenna support beam, including the controller layout are discussed.

  15. The tubular separate first wall for ITER EDA

    International Nuclear Information System (INIS)

    Pizzuto, A.; Riccardi, B.; Salpietro, E.

    1994-01-01

    The first wall is one of the most loaded plasma-facing components, the heat flux is such that the thermal stresses are the most important design concern. In addition, the First Wall shall resist the eddy current induced plasma disruption, the high pressure of the coolant without leaking ( -6 Torr-lit/sec.) and it should maintain its properties under fast neutron flux (dose up to 3 MW/m 2 ). The tubular solution is the most suitable one to cope with the thermal stresses, the use of double wall reduces the risk of leaks inside the vacuum vessel by avoiding the growth of a crack through both walls: the soft brazing in between walls stops the growth of a crack from one tube to the other. The eddy currents induced in the tubes are low and the Halo current flowing poloidally in the tubes exert a radial pressure which is supported by the blanket box via ad hoc supporting points provided in between first wall and blanket. Conclusions from the thermo-hydraulic analysis and the electromagnetic analysis will be presented including dynamic analysis. Also results of preliminary technological tests on coatings will be discussed

  16. Soft tubular microfluidics for 2D and 3D applications

    Science.gov (United States)

    Xi, Wang; Kong, Fang; Yeo, Joo Chuan; Yu, Longteng; Sonam, Surabhi; Dao, Ming; Gong, Xiaobo; Teck Lim, Chwee

    2017-10-01

    Microfluidics has been the key component for many applications, including biomedical devices, chemical processors, microactuators, and even wearable devices. This technology relies on soft lithography fabrication which requires cleanroom facilities. Although popular, this method is expensive and labor-intensive. Furthermore, current conventional microfluidic chips precludes reconfiguration, making reiterations in design very time-consuming and costly. To address these intrinsic drawbacks of microfabrication, we present an alternative solution for the rapid prototyping of microfluidic elements such as microtubes, valves, and pumps. In addition, we demonstrate how microtubes with channels of various lengths and cross-sections can be attached modularly into 2D and 3D microfluidic systems for functional applications. We introduce a facile method of fabricating elastomeric microtubes as the basic building blocks for microfluidic devices. These microtubes are transparent, biocompatible, highly deformable, and customizable to various sizes and cross-sectional geometries. By configuring the microtubes into deterministic geometry, we enable rapid, low-cost formation of microfluidic assemblies without compromising their precision and functionality. We demonstrate configurable 2D and 3D microfluidic systems for applications in different domains. These include microparticle sorting, microdroplet generation, biocatalytic micromotor, triboelectric sensor, and even wearable sensing. Our approach, termed soft tubular microfluidics, provides a simple, cheaper, and faster solution for users lacking proficiency and access to cleanroom facilities to design and rapidly construct microfluidic devices for their various applications and needs.

  17. Design and analysis of tubular permanent magnet linear wave generator.

    Science.gov (United States)

    Si, Jikai; Feng, Haichao; Su, Peng; Zhang, Lufeng

    2014-01-01

    Due to the lack of mature design program for the tubular permanent magnet linear wave generator (TPMLWG) and poor sinusoidal characteristics of the air gap flux density for the traditional surface-mounted TPMLWG, a design method and a new secondary structure of TPMLWG are proposed. An equivalent mathematical model of TPMLWG is established to adopt the transformation relationship between the linear velocity of permanent magnet rotary generator and the operating speed of TPMLWG, to determine the structure parameters of the TPMLWG. The new secondary structure of the TPMLWG contains surface-mounted permanent magnets and the interior permanent magnets, which form a series-parallel hybrid magnetic circuit, and their reasonable structure parameters are designed to get the optimum pole-arc coefficient. The electromagnetic field and temperature field of TPMLWG are analyzed using finite element method. It can be included that the sinusoidal characteristics of air gap flux density of the new secondary structure TPMLWG are improved, the cogging force as well as mechanical vibration is reduced in the process of operation, and the stable temperature rise of generator meets the design requirements when adopting the new secondary structure of the TPMLWG.

  18. Design and Analysis of Tubular Permanent Magnet Linear Wave Generator

    Directory of Open Access Journals (Sweden)

    Jikai Si

    2014-01-01

    Full Text Available Due to the lack of mature design program for the tubular permanent magnet linear wave generator (TPMLWG and poor sinusoidal characteristics of the air gap flux density for the traditional surface-mounted TPMLWG, a design method and a new secondary structure of TPMLWG are proposed. An equivalent mathematical model of TPMLWG is established to adopt the transformation relationship between the linear velocity of permanent magnet rotary generator and the operating speed of TPMLWG, to determine the structure parameters of the TPMLWG. The new secondary structure of the TPMLWG contains surface-mounted permanent magnets and the interior permanent magnets, which form a series-parallel hybrid magnetic circuit, and their reasonable structure parameters are designed to get the optimum pole-arc coefficient. The electromagnetic field and temperature field of TPMLWG are analyzed using finite element method. It can be included that the sinusoidal characteristics of air gap flux density of the new secondary structure TPMLWG are improved, the cogging force as well as mechanical vibration is reduced in the process of operation, and the stable temperature rise of generator meets the design requirements when adopting the new secondary structure of the TPMLWG.

  19. Standing wave brass-PZT square tubular ultrasonic motor.

    Science.gov (United States)

    Park, Soonho; He, Siyuan

    2012-09-01

    This paper reports a standing wave brass-PZT tubular ultrasonic motor. The motor is composed of a brass square tube with two teeth on each tube end. Four PZT plates are attached to the outside walls of the brass tube. The motor requires only one driving signal to excite vibration in a single bending mode to generate reciprocating diagonal trajectories of teeth on the brass tube ends, which drive the motor to rotate. Bi-directional rotation is achieved by exciting different pairs of PZT plates to switch the bending vibration direction. Through using the brass-PZT tube structure, the motor can take high magnitude vibration to achieve a high output power in comparison to PZT tube based ultrasonic motors. Prototypes are fabricated and tested. The dimension of the brass-PZT tube is 3.975mm×3.975mm×16mm. Measured performance is a no-load speed of >1000RPM, a stall torque of 370μNm and a maximum output power of 16 mW when a sinusoidal driving voltage of 50V is applied. The working frequencies of the motor are 46,050Hz (clockwise) and 46,200Hz (counter-clockwise). Copyright © 2012. Published by Elsevier B.V.

  20. Distal renal tubular acidosis in two children with acquired hypothyroidism.

    Science.gov (United States)

    Guerra-Hernández, Norma E; Ordaz-López, Karen V; Vargas-Poussou, Rosa; Escobar-Pérez, Laura; García-Nieto, Víctor M

    2018-04-28

    Two cases of children diagnosed with renal tubular acidosis (RTA) associated with autoimmune hypothyroidism are presented. Case 1 developed an intestinal ileus at the age of five in the context of a respiratory problem. The tests performed confirmed metabolic acidosis, hyperchloraemia, hypokalaemia and nephrocalcinosis. Case 2 was diagnosed with hypothyroidism at the age of 11, and with RTA two years later. In both patients, the diagnosis of RTA was verified when decreased maximum urinary pCO 2 was found. In case 2, a proximal bicarbonate leak (type 3 RTA) was also confirmed. This was the first case to be published on the topic. The causes of RTA in patients with hypothyroidism are reviewed. The deleterious effect on the kidneys may be due to the absence of thyroid hormone and/or autoantibodies in the cases of autoimmune hypothyroidism. Copyright © 2018 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  1. Oily bilge water treatment with a tubular ultrafiltration system

    Energy Technology Data Exchange (ETDEWEB)

    Harris, L.R.; Jackson, D.F.; Schatzberg, P.

    1976-11-01

    The Navy has been developing various oil pollution abatement systems. One potential process for the separation of oil in bilge water is ultrafiltration, a pressure-driven membrane process which can separate, concentrate, and fractionate macromolecular solutes and suspended species from water. A tubular ultrafiltration system using cellulosic and noncellulosic membranes was tested with bilge oil obtained from a patrol craft. Tests were also conducted with tap water, river water, a turbine lubricating oil, and a fuel oil, alone and in combination with a nonionic detergent. The addition of the detergent was observed to result in a steeper flux decline than when any of the fluids were evaluated alone. Both membrane types produced a permeate with an oil content generally less than 15 mg/l. Although the noncellulosic membranes exhibited higher flux rates than the cellulosic membranes, only the former could be restored by a cleaning operation to its initial water flux after experiencing a decline in flux. A cumulative irreversible flux decline was exhibited by the cellulosic membrane. Cleaning operations, some of which were time-consuming, consisted of flushing the membrane with ultrafiltrate, distilled water, tap water, or the manufacturer's enzyme-detergent formulation. Only the last of these, when employed at elevated temperature (125/sup 0/F), restored the initial water flux of the noncellulosic membrane.

  2. Design and Analysis of Tubular Permanent Magnet Linear Wave Generator

    Science.gov (United States)

    Si, Jikai; Feng, Haichao; Su, Peng; Zhang, Lufeng

    2014-01-01

    Due to the lack of mature design program for the tubular permanent magnet linear wave generator (TPMLWG) and poor sinusoidal characteristics of the air gap flux density for the traditional surface-mounted TPMLWG, a design method and a new secondary structure of TPMLWG are proposed. An equivalent mathematical model of TPMLWG is established to adopt the transformation relationship between the linear velocity of permanent magnet rotary generator and the operating speed of TPMLWG, to determine the structure parameters of the TPMLWG. The new secondary structure of the TPMLWG contains surface-mounted permanent magnets and the interior permanent magnets, which form a series-parallel hybrid magnetic circuit, and their reasonable structure parameters are designed to get the optimum pole-arc coefficient. The electromagnetic field and temperature field of TPMLWG are analyzed using finite element method. It can be included that the sinusoidal characteristics of air gap flux density of the new secondary structure TPMLWG are improved, the cogging force as well as mechanical vibration is reduced in the process of operation, and the stable temperature rise of generator meets the design requirements when adopting the new secondary structure of the TPMLWG. PMID:25050388

  3. Quantitation of renal function with glomerular and tubular agents

    International Nuclear Information System (INIS)

    Dubovsky, E.V.; Russell, C.D.

    1982-01-01

    Quantitative methods to measure the glomerular and tubular function of the kidneys with radionuclides have been available for many years. They have not been widely used because the techniques and the calculations exceeded the scope of routine nuclear medicine practice. Validation of simplified methods and the introduction of computer technology have made measurement of the effective renal plasma flow (ERPF) and the glomerular filtration rate (GFR) simple enough so that they can be performed reproducibly in most nuclear medicine departments. The estimation of ERPF with radioiodinated OIH and GFR with /sup 99m/TcDTPA can be achieved in many ways, all of which yield clinically useful results. How to get the best results using the simplest methods is still unclear. The required accuracy depends on the intended clinical use. Our preference at the present time is to use a single or double plasma sample to calculate global ERPF or GFR, and to use the 1-2 min OIH or 1-3 min Tc-DTPA uptake to calculate relative function of the two kidneys (split function ERPF or GFR). The choice of method will be influenced by local factors, such as the nature of the patient population, the case volume, and the resources available. A desirable goal for future studies is to document carefully the capabilities and limitations of each alternative method, so that the choice can be rational

  4. STUDY THE CREEP OF TUBULAR SHAPED FIBER REINFORCED COMPOSITES

    Directory of Open Access Journals (Sweden)

    Najat J. Saleh

    2013-05-01

    Full Text Available Inpresent work tubular –shaped fiber reinforced composites were manufactured byusing two types of resins ( Epoxy and unsaturated polyester and separatelyreinforced with glass, carbon and kevlar-49 fibers (filament and woven roving,hybrid reinforcement composites of these fibers were also prepared. The fiberswere wet wound on a mandrel using a purposely designed winding machine,developed by modifying an ordinary lathe, in winding angle of 55° for filament. A creep test was made of either the fulltube or specimens taken from it. Creep was found to increase upon reinforcementin accordance to the rule of mixture and mainly decided by the type of singleor hybridized fibers. The creep behavior, showed that the observed strain tendsto appear much faster at higher temperature as compared with that exhibited atroom temperate. The creep rate also found to be depending on fiber type, matrixtype, and the fiber /matrix bonding. The creep energy calculated fromexperimental observations was found to exhibit highest value for hybridizedreinforcement.

  5. HIGH-TEMPERATURE TUBULAR SOLID OXIDE FUEL CELL GENERATOR DEVELOPMENT

    Energy Technology Data Exchange (ETDEWEB)

    S.E. Veyo

    1998-09-01

    During the Westinghouse/USDOE Cooperative Agreement period of November 1, 1990 through November 30, 1997, the Westinghouse solid oxide fuel cell has evolved from a 16 mm diameter, 50 cm length cell with a peak power of 1.27 watts/cm to the 22 mm diameter, 150 cm length dimensions of today's commercial prototype cell with a peak power of 1.40 watts/cm. Accompanying the increase in size and power density was the elimination of an expensive EVD step in the manufacturing process. Demonstrated performance of Westinghouse's tubular SOFC includes a lifetime cell test which ran for a period in excess of 69,000 hours, and a fully integrated 25 kWe-class system field test which operated for over 13,000 hours at 90% availability with less than 2% performance degradation over the entire period. Concluding the agreement period, a 100 kW SOFC system successfully passed its factory acceptance test in October 1997 and was delivered in November to its demonstration site in Westervoort, The Netherlands.

  6. Roundness and straightness measurement of ceramic beam ducts for the 3 GeV-synchrotron

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, Daiji; Kinsho, Michikazu; Kanazawa, Kenichiro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Kubo, Tomio; Sato, Yoshihiro; Saito, Yoshio [High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan)

    2001-12-01

    Large aperture ({phi}200 - {phi}250) cylindrical beam ducts consisting of alumina ceramics will be used in the 3 GeV-synchrotron of High Intensity Proton Accelerator Facility. In particular, bending magnet sections require the large length ({approx}3500 mm) ceramic beam duct connecting several unit ducts whose length is around 500-1000 mm by metallizing and glazing. Therefore it is very important to evaluate roundness and straightness of ceramic ducts because we have to compensate contact area large and have to minimize misalignment of ducts connected. We developed an apparatus for measuring roundness and straightness, and we completed data analysis method using general application software Excel as well as measuring method. Then we have taken data, and have evaluated value of roundness and straightness for the first time about 7 pieces (3 kinds) of ceramic beam duct. At last we have found out that unit ceramic ducts can be made after sintering without polishing with roundness several hundred micron ({mu}m) and straightness around 0.2-1 mm, and that straightness has a tendency to become large as duct length increases as well as roundness increases directly proportional to the maximum oblateness. (author)

  7. Straight configuration saphenous vein transposition to popliteal artery for vascular access.

    Science.gov (United States)

    Caco, Gentian; Golemi, Dhurata; Likaj, Eriola

    2017-03-21

    The saphenous vein is commonly used as a vascular graft in peripheral artery surgery but rarely used for vascular access. The literature on straight configuration saphenous vein transposition to the popliteal artery is scarce. Here we present two cases of straight configuration saphenous vein transposition to the popliteal artery for vascular access, the surgical technique and respective follow-up. Two young men, aged 29 and 36 years, were chosen for lower-limb vascular access for hemodialysis. The first patient was paraplegic since birth. He used his arms to move so upper extremity vascular access was avoided. The second patient presented with an infected upper extremity arteriovenous graft (AVG) and after multiple closed AVFs he had no more available arm veins. Both patients received autologous lower extremity straight configuration saphenous vein transpositions to the popliteal artery under spinal anesthesia in May and October 2012, respectively. Cannulation of the fistula was allowed after one month. There were no early complications. Slight swelling on the leg appeared in one of the patients. Both fistulas were still functional after 36 and 32 months, respectively. The straight configuration saphenous vein transposition to popliteal artery is simple to perform, offers a long and straight segment for cannulation and may be a suitable autologous vascular access in selected patients.

  8. Investigation into the limitations of straightness interferometers using a multisensor-based error separation method

    Science.gov (United States)

    Weichert, Christoph; Köchert, Paul; Schötka, Eugen; Flügge, Jens; Manske, Eberhard

    2018-06-01

    The uncertainty of a straightness interferometer is independent of the component used to introduce the divergence angle between the two probing beams, and is limited by three main error sources, which are linked to each other: their resolution, the influence of refractive index gradients and the topography of the straightness reflector. To identify the configuration with minimal uncertainties under laboratory conditions, a fully fibre-coupled heterodyne interferometer was successively equipped with three different wedge prisms, resulting in three different divergence angles (4°, 8° and 20°). To separate the error sources an independent reference with a smaller reproducibility is needed. Therefore, the straightness measurement capability of the Nanometer Comparator, based on a multisensor error separation method, was improved to provide measurements with a reproducibility of 0.2 nm. The comparison results revealed that the influence of the refractive index gradients of air did not increase with interspaces between the probing beams of more than 11.3 mm. Therefore, over a movement range of 220 mm, the lowest uncertainty was achieved with the largest divergence angle. The dominant uncertainty contribution arose from the mirror topography, which was additionally determined with a Fizeau interferometer. The measured topography agreed within  ±1.3 nm with the systematic deviations revealed in the straightness comparison, resulting in an uncertainty contribution of 2.6 nm for the straightness interferometer.

  9. Commissioning of the PF Ring after the Reconstruction for the Straight-sections Upgrade

    International Nuclear Information System (INIS)

    Honda, T.; Asaoka, S.; Cheng, W. X.; Haga, K.; Harada, K.; Hori, Y.; Izawa, M.; Kasuga, T.; Kobayashi, Y.; Maezawa, H.; Mishina, A.; Mitsuhashi, T.; Miyajima, T.; Miyauchi, H.; Nagahashi, S.; Nogami, T.; Obina, T.; Pak, C. O.; Sakanaka, S.; Sasaki, H.

    2007-01-01

    At the 2.5-GeV ring of the Photon Factory, a large reconstruction of the lattice around the straight sections has been accomplished in 2005. Thus reconstruction is the main part of the straight-sections upgrade project to rebuild existing undulators and to increase the number of undulator beamlines. As a result of the reconstruction, four short straight sections have been newly created and the lengths of the existing straight sections have been much extended. To exploit the new straight sections, short-period narrow-gap undulators which have a sufficiently high brilliance in hard x-ray range have been developed. The reconstruction work of the ring was completed in a seven-month shutdown from March to September, 2005. In the area over two thirds of the storage ring, all the quadrupole magnets and all the beam ducts have been renewed and rearranged to construct the new lattice. Recommissioning of the storage ring was finished at the end of October, 2005. Though we made no in-situ baking for the beam ducts, recovery of the beam lifetime has favorably progressed due to the vacuum scrubbing by the synchrotron radiation

  10. Design and performance of tubular flat-plate solid oxide fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, T.; Ikeda, D.; Kanagawa, H. [NTT Integrated Information & Energy Systems Labs., Tokyo (Japan)] [and others

    1996-12-31

    With the growing interest in conserving the environmental conditions, much attention is being paid to Solid Oxide Fuel Cell (SOFC), which has high energy-conversion efficiency. Many organizations have conducted studies on tubular and flat type SOFCs. Nippon Telegraph and Telephone Corporation (NTT) has studied a combined tubular flat-plate SOFC, and already presented the I-V characteristics of a single cell. Here, we report the construction of a stack of this SOFC cell and successful generation tests results.

  11. Effect of cisplatin on renal haemodynamics and tubular function in the dog kidney

    DEFF Research Database (Denmark)

    Daugaard, G; Abildgaard, U; Holstein-Rathlou, N H

    1987-01-01

    Administration of cisplatin (5 mg/kg) to dogs results in polyuric renal failure due initially to a proximal tubular functional impairment. 48-72 h after the cisplatin administration the depressed renal function can be attributed to impairment of proximal as well as distal tubular reabsorptive cap...... capacities associated with increased renal vascular resistance. The polyuria seems to be due to the impaired reabsorption rate in the distal nephron segments....

  12. Facile Fabrication of Uniform Polyaniline Nanotubes with Tubular Aluminosilicates as Templates

    OpenAIRE

    Zhang, Long; Liu, Peng

    2008-01-01

    AbstractThe uniform polyaniline (PANI) nanotubes, with inner diameter, outer diameter, and tubular thickness of 40, 60, and 10 nm, respectively, were prepared successfully by using natural tubular aluminosilicates as templates. The halloysite nanotubes were coated with PANI via the in situ chemical oxidation polymerization. Then the templates were etched with HCl/HF solution. The PANI nanotubes were characterized using FTIR, X-ray diffraction, and transmission electron microscopy. The conduct...

  13. Renal tubular dysfunction presenting as recurrent hypokalemic periodic quadriparesis in systemic lupus erythematosus

    Directory of Open Access Journals (Sweden)

    D Prasad

    2014-01-01

    Full Text Available We report recurrent hypokalemic periodic quadriparesis in a 30-year-old woman. Patient had also symptoms of multiple large and small joint pain, recurrent oral ulceration, photosensitivity and hair loss that were persisting since last 6 months and investigations revealed systemic lupus erythematosus (SLE with distal tubular acidosis. Our patient was successfully treated with oral potassium chloride, sodium bicarbonate, hydroxychloroquine and a short course of steroids. Thus, tubular dysfunction should be carefully assessed in patients with SLE.

  14. Hypokalaemia and Renal Tubular Acidosis due to Abuse of Nurofen Plus

    Directory of Open Access Journals (Sweden)

    M. J. Blackstock

    2012-01-01

    Full Text Available Nurofen Plus is a common analgesic containing ibuprofen and codeine. We present a case of a 38-year-old lady who developed renal tubular acidosis with severe hypokalaemia, after chronic abuse of Nurofen Plus tablets. She presented with confusion and profound biochemical abnormalities requiring critical care admission for electrolyte replacement. Ibuprofen causes renal tubular acidosis due to its effects on carbonic anhydrase activity.

  15. Ground Vibration Isolation of Multiple Scattering by Using Rows of Tubular Piles as Barriers

    Directory of Open Access Journals (Sweden)

    Miao-miao Sun

    2014-01-01

    Full Text Available A new formal solution for the multiple scattering of plane harmonic waves by a group of arbitrary configuration tubular piles in an elastic total space is derived. Each order of scattering satisfies prescribed boundary conditions at the interface of tubular piles, which is delivered as the sum of incident and scattering waves. The first order performs the scattering wave by each scattered pile and the subsequent orders resulted from the excitation of each pile of first order of scattering from the remaining tubular piles. Advanced scattering orders can be regarded as the same manners. Several series of scattering coefficients are figured out with the aids of addition theorem so that the exact steady-state solution for the scattered displacement and stress is obtained. Particularly, when internal diameter of tubular piles tends to be infinitely small, it degenerates to a solid pile problem. By imposing the normalized displacement amplitudes and transmissibility indices, the influences of specific parameters such as scattering orders, internal and external diameter ratio of piles, pile material rigidity, position and distances between tubular pile and pile rows, and pile numbers are discussed. Certain recommended conclusions have been drawn as the guidelines of practical engineering design for discontinuous barrier of tubular piles.

  16. The effect of acyclovir on the tubular secretion of creatinine in vitro

    Directory of Open Access Journals (Sweden)

    Aleksa Katarina

    2010-12-01

    Full Text Available Abstract Background While generally well tolerated, severe nephrotoxicity has been observed in some children receiving acyclovir. A pronounced elevation in plasma creatinine in the absence of other clinical manifestations of overt nephrotoxicity has been frequently documented. Several drugs have been shown to increase plasma creatinine by inhibiting its renal tubular secretion rather than by decreasing glomerular filtration rate (GFR. Creatinine and acyclovir may be transported by similar tubular transport mechanisms, thus, it is plausible that in some cases, the observed increase in plasma creatinine may be partially due to inhibition of tubular secretion of creatinine, and not solely due to decreased GFR. Our objective was to determine whether acyclovir inhibits the tubular secretion of creatinine. Methods Porcine (LLC-PK1 and human (HK-2 renal proximal tubular cell monolayers cultured on microporous membrane filters were exposed to [2-14C] creatinine (5 μM in the absence or presence of quinidine (1E+03 μM, cimetidine (1E+03 μM or acyclovir (22 - 89 μM in incubation medium. Results Results illustrated that in evident contrast to quinidine, acyclovir did not inhibit creatinine transport in LLC-PK1 and HK-2 cell monolayers. Conclusions The results suggest that acyclovir does not affect the renal tubular handling of creatinine, and hence, the pronounced, transient increase in plasma creatinine is due to decreased GFR, and not to a spurious increase in plasma creatinine.

  17. Inner Surface Chirality of Single-Handed Twisted Carbonaceous Tubular Nanoribbons.

    Science.gov (United States)

    Liu, Dan; Li, Baozong; Guo, Yongmin; Li, Yi; Yang, Yonggang

    2015-11-01

    Single-handed twisted 4,4'-biphenylene-bridged polybissilsesquioxane tubular nanoribbons and single-layered nanoribbons were prepared by tuning the water/ethanol volume ratio in the reaction mixture at pH = 11.6 through a supramolecular templating approach. The single-layered nanoribbons were formed by shrinking tubular nanoribbons after the removal of the templates. In addition, solvent-induced handedness inversion was achieved. The handedness of the polybissilsesquioxanes could be controlled by changing the ethanol/water volume ratio in the reaction mixture. After carbonization at 900 °C for 4.0 h and removal of silica, single-handed twisted carbonaceous tubular nanoribbons and single-layered nanoribbons with micropores in the walls were obtained. X-ray diffraction and Raman spectroscopy analyses indicated that the carbon is predominantly amorphous. The circular dichroism spectra show that the twisted tubular nanoribbons exhibit optical activity, while the twisted single-layered nanoribbons do not. The results shown here indicate that chirality is transferred from the organic self-assemblies to the inner surfaces of the 4,4'-biphenylene-bridged polybissilsesquioxane tubular nanoribbons and subsequently to those of the carbonaceous tubular nanoribbons. © 2015 Wiley Periodicals, Inc.

  18. Prevalence of renal tubular dysfunction in beta thalassemia minor in shiraz

    Directory of Open Access Journals (Sweden)

    Ali Moradi Nakhodcheri

    2012-02-01

    Full Text Available  Background & objective: β-Thalassemia minor is an asymptomatic hereditary disease. The first study on the relation of renal tubular dysfunction and β-thalassemia minor was performed in 2002 but those studies seem inadequate.The main goal of this study is through evaluation of renal tubular function in 100 patients with thalassemia minor. Materials & Methods: 100 patients with β- thalassemia which confirmed by hemoglobin electrophoresis and CBC as well as RBC indices were studied.14 out of 100 cases exit because of Urinary Tract Infection, diabetes mellitus or hypertension.Complete chemistry profile was performed on serum and urine of all reminder 86 patients (46 female and 40 male. Patients classified into two groups: β-thalassemia minor with anemia and without anemia. Another control group include 50 healthy individuals also considered.Then data analyzed by proper statistical methods. Results: 20 out of 86 reminder cases e.g. 24% showed at least one index of renal tubular dysfunction.58% of patients was been anemic and 42% non anemic. The most prominent tubular dysfunction was seen in a 29 years old lady with glucosuria and without anemia. conclusion: β-Thalassemia minor is common in Iran specially in Fars province. This study revealed significant renal tubular dysfunction in patient with β-thalassemia minor. So it is necessary to check out thalassemic patients for renal function tests periodically. Key words: β-thalassemia, minor,renal tubular dysfunction

  19. pH measurement of tubular vacuoles of an arbuscular mycorrhizal fungus, Gigaspora margarita.

    Science.gov (United States)

    Funamoto, Rintaro; Saito, Katsuharu; Oyaizu, Hiroshi; Aono, Toshihiro; Saito, Masanori

    2015-01-01

    Arbuscular mycorrhizal fungi play an important role in phosphate supply to the host plants. The fungal hyphae contain tubular vacuoles where phosphate compounds such as polyphosphate are accumulated. Despite their importance for the phosphate storage, little is known about the physiological properties of the tubular vacuoles in arbuscular mycorrhizal fungi. As an indicator of the physiological state in vacuoles, we measured pH of tubular vacuoles in living hyphae of arbuscular mycorrhizal fungus Gigaspora margarita using ratio image analysis with pH-dependent fluorescent probe, 6-carboxyfluorescein. Fluorescent images of the fine tubular vacuoles were obtained using a laser scanning confocal microscope, which enabled calculation of vacuolar pH with high spatial resolution. The tubular vacuoles showed mean pH of 5.6 and a pH range of 5.1-6.3. These results suggest that the tubular vacuoles of arbuscular mycorrhizal fungi have a mildly acidic pH just like vacuoles of other fungal species including yeast and ectomycorrhizal fungi.

  20. Review: peripheral nerve regeneration using non-tubular alginate gel crosslinked with covalent bonds.

    Science.gov (United States)

    Hashimoto, Tadashi; Suzuki, Yoshihisa; Suzuki, Kyoko; Nakashima, Toshihide; Tanihara, Masao; Ide, Chizuka

    2005-06-01

    We have developed a nerve regeneration material consisting of alginate gel crosslinked with covalent bonds. in the first part of this study, we attempted to analyze nerve regeneration through alginate gel in the early stages within 2 weeks. in the second part, we tried to regenerate cat peripheral nerve by using alginate tubular or non-tubular nerve regeneration devices, and compared their efficacies. Four days after surgery, regenerating axons grew without Schwann cell investment through the partially degraded alginate gel, being in direct contact with the alginate without a basal lamina covering. One to 2 weeks after surgery, regenerating axons were surrounded by common Schwann cells, forming small bundles, with some axons at the periphery being partly in direct contact with alginate. At the distal stump, numerous Schwann cells had migrated into the alginate 8-14 days after surgery. Remarkable restorations of the 50-mm gap in cat sciatic nerve were obtained after a long term by using tubular or non-tubular nerve regeneration material consisting mainly of alginate gel. However, there was no significant difference between both groups at electrophysiological and morphological evaluation. Although, nowadays, nerve regeneration materials being marketed mostly have a tubular structure, our results suggest that the tubular structure is not indispensable for peripheral nerve regeneration.

  1. Hyperammonemia associated with distal renal tubular acidosis or urinary tract infection: a systematic review.

    Science.gov (United States)

    Clericetti, Caterina M; Milani, Gregorio P; Lava, Sebastiano A G; Bianchetti, Mario G; Simonetti, Giacomo D; Giannini, Olivier

    2018-03-01

    Hyperammonemia usually results from an inborn error of metabolism or from an advanced liver disease. Individual case reports suggest that both distal renal tubular acidosis and urinary tract infection may also result in hyperammonemia. A systematic review of the literature on hyperammonemia secondary to distal renal tubular acidosis and urinary tract infection was conducted. We identified 39 reports on distal renal tubular acidosis or urinary tract infections in association with hyperammonemia published between 1980 and 2017. Hyperammonemia was detected in 13 children with distal renal tubular acidosis and in one adult patient with distal renal tubular acidosis secondary to primary hyperparathyroidism. In these patients a negative relationship was observed between circulating ammonia and bicarbonate levels (P urinary tract infection was complicated by acute hyperammonemia and symptoms and signs of acute neuronal dysfunction, such as an altered level of consciousness, convulsions and asterixis, often associated with signs of brain edema, such as anorexia and vomiting. Urea-splitting bacteria were isolated in 28 of the 31 cases. The urinary tract was anatomically or functionally abnormal in 30 of these patients. This study reveals that both altered distal renal tubular acidification and urinary tract infection may be associated with relevant hyperammonemia in both children and adults.

  2. Neck Muscle Moment Arms Obtained In-Vivo from MRI: Effect of Curved and Straight Modeled Paths.

    Science.gov (United States)

    Suderman, Bethany L; Vasavada, Anita N

    2017-08-01

    Musculoskeletal models of the cervical spine commonly represent neck muscles with straight paths. However, straight lines do not best represent the natural curvature of muscle paths in the neck, because the paths are constrained by bone and soft tissue. The purpose of this study was to estimate moment arms of curved and straight neck muscle paths using different moment arm calculation methods: tendon excursion, geometric, and effective torque. Curved and straight muscle paths were defined for two subject-specific cervical spine models derived from in vivo magnetic resonance images (MRI). Modeling neck muscle paths with curvature provides significantly different moment arm estimates than straight paths for 10 of 15 neck muscles (p straight lines to model muscle paths can lead to overestimating neck extension moment. However, moment arm methods for curved paths should be investigated further, as different methods of calculating moment arm can provide different estimates.

  3. First straw straightness measurements on a 4-plane end-cap ATLAS TRT wheel

    CERN Document Server

    Lucotte, A; Mitsou, V A; Mouraviev, S V; Nadtochy, A

    2001-01-01

    This document reports the first results and their interpretation of the straw straightness measurements that have been performed on the first 4-plane end-cap prototype of the ATLAS TRT. Section 2 presents the experimental setup used for the measurements, as well as a review of the data sample used to perform this study. It also provides a description of the method used to assess straw straightness, which is based on the measurements of the maximal gas gain deviation (``straw eccentricity'') seen along the straw. Section 3 reports the results of straw straightness for the 4-plane module, including corrections due to the gas flow. The effect of energy resolution degradation is also explained and results in terms of wire offset are reported. In Section 4, the straw bending due to an applied lateral deformation is measured, and finally Section 5 reviews the conclusions.

  4. Status of PF-ring commissioning after the reconstruction for the straight-sections upgrade

    International Nuclear Information System (INIS)

    Tanimoto, Yasunori; Miyauchi, Hiroshi; Honda, Tohru; Kobayashi, Yukinori

    2006-01-01

    The upgrade project of the straight sections at the PF-ring enables the reinforcement of insertion devices and their beamlines. As a main part of this project, a large-scale reconstruction of the storage ring was carried out from March to September in 2005. The lattice configuration was modified to create short straight sections of 1.4 m and to extend the existing straight sections. Optical functions of the short sections were optimized for short-gap mini-pole undulators as X-ray sources. The first mini-pole undulator SGU no.17 has been operated for a protein crystallography. A recommissioning of the ring was conducted for about one month, and user experiments were restarted on 18th October 2005 according to schedule. The recovery of the beam lifetime due to the process of the vacuum scrubbing has been favorably progressed. (author)

  5. Calculation of gas Bremsstrahlung power from straight sections of storage ring at SSRF

    International Nuclear Information System (INIS)

    Hua Zhengdong; Xu Xunjiang; Fang Keming; Xu Jiaqiang

    2008-01-01

    The Shanghai Synchrotron Radiation Facility (SSRF) is a third-generation synchrotron radiation light source with 3.5 GeV in energy, which is composed of the linear accelerator, the booster and the storage ring. The storage ring provides 16 standard straight sections of 6.5 m and 4 long straight sections of 12 meters. Gas Bremsstrahlung (GB) produced by the interaction of the stored beam with the residual gas molecules in straight section, which is so intense and has a very small angular that the GB spectra, the GB power and the GB power distribution should be known. The characters of GB are studied by means of Fluka Monte Carlo code. Our result shows agreement with those obtained by the experiential formulae. (authors)

  6. Synthesis method based on solution regions for planar four bar straight line linkages

    International Nuclear Information System (INIS)

    Lai Rong, Yin; Cong, Mao; Jian you, Han; Tong, Yang; Juan, Huang

    2012-01-01

    An analytical method for synthesizing and selecting desired four-bar straight line mechanisms based on solution regions is presented. Given two fixed pivots, the point position and direction of the target straight line, an infinite number of mechanism solutions can be produced by employing this method, both in the general case and all three special cases. Unifying the straight line direction and the displacement from the given point to the instant center into the same form with different angles as parameters, infinite mechanism solutions can be expressed with different solution region charts. The mechanism property graphs have been computed to enable the designers to find out the involved mechanism information more intuitively and avoid aimlessness in selecting optimal mechanisms

  7. Novel Straight and Circular Road Driving Control of Electric Power Assisted Wheelchair Based on Fuzzy Algorithm

    Science.gov (United States)

    Seki, Hirokazu; Tadakuma, Susumu

    This paper describes a novel straight and circular road driving control scheme for electric power assisted wheelchairs. “Electric power assisted wheelchair” which assists the driving force by electric motors is expected to be widely used as a mobility support system for elderly people and disabled people, however, the performance of the straight and circular road driving must be further improved because the two wheels drive independently. This paper proposes a novel driving control scheme based on fuzzy algorithm to realize the stable and reliable driving on straight and circular roads. The suitable assisted torque of the right and left wheels is determined by fuzzy algorithm based on the posture angular velocity of the wheelchair and the human input torque proportion of the right and left wheels. Some experiments on the practical roads show the effectiveness of the proposed control system.

  8. Controllable synthesis of helical, straight, hollow and nitrogen-doped carbon nanofibers and their magnetic properties

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xun [State Key Laboratory of Coordination Chemistry, Nanjing National Laboratory of Microstructure, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093 (China); State Key Laboratory of Soil and Sustainable Agriculture, Institute of Soil Science, Chinese Academy of Sciences, Nanjing 210008 (China); Xu, Zheng, E-mail: zhengxu@nju.edu.cn [State Key Laboratory of Coordination Chemistry, Nanjing National Laboratory of Microstructure, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093 (China)

    2012-12-15

    Graphical abstract: The helical, straight and hollow carbon nanofibers can be selectively synthesized by adjusting either the reaction temperature or feed gas composition. Display Omitted Highlights: ► CNFs were synthesized via pyrolysis of acetylene on copper NPs. ► The helical, straight, hollow and N-doped CNFs can be selectively synthesized. ► The growth mechanism of different types of CNFs was proposed. -- Abstract: Carbon nanofibers (CNFs) with various morphologies were synthesized by catalytic pyrolysis of acetylene on copper nanoparticles which were generated from the in situ decomposition of copper acetylacetonate. The morphology of the pristine and acid-washed CNFs was investigated by field emission scanning electron microscope and high-resolution transmission electron microscope. Helical, straight and hollow CNFs can be selectively synthesized by adjusting either the reaction temperature or feed gas composition. The growth mechanism for these three types of CNFs was proposed.

  9. "Appearance potent"? A content analysis of UK gay and straight men's magazines.

    Science.gov (United States)

    Jankowski, Glen S; Fawkner, Helen; Slater, Amy; Tiggemann, Marika

    2014-09-01

    With little actual appraisal, a more 'appearance potent' (i.e., a reverence for appearance ideals) subculture has been used to explain gay men's greater body dissatisfaction in comparison to straight men's. This study sought to assess the respective appearance potency of each subculture by a content analysis of 32 issues of the most read gay (Attitude, Gay Times) and straight men's magazines (Men's Health, FHM) in the UK. Images of men and women were coded for their physical characteristics, objectification and nudity, as were the number of appearance adverts and articles. The gay men's magazines featured more images of men that were appearance ideal, nude and sexualized than the straight men's magazines. The converse was true for the images of women and appearance adverts. Although more research is needed to understand the effect of this content on the viewer, the findings are consistent with a more appearance potent gay male subculture. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  10. Implanting straight into cochlea risks the facial nerve: a Cartesian coordinate study.

    Science.gov (United States)

    Deshpande, Anita S; Wendell Todd, N

    2016-12-01

    To describe the straight-into-cochlea line that affords the best access for an electrode array to enter via the round window, and how this line relates to the facial nerve, the incus, and mastoid size. The straight-into-cochlea line is important to minimize the cochlear trauma and maximize the likelihood of placement into the scala tympani. High-resolution CT scans were obtained for ten craniums with the extremes of large (N = 5) and small (N = 5) mastoid pneumatization; the specimens were from a series of 41 ear normal craniums. Using FIJI, a publicly available software program, the straight-into-cochlea insertion line was determined by defining the x-y-z coordinates of the middle of the round window and a point 6.0 mm into the cochlea on its centrifugal wall. Then, from the extended straight-into-cochlea insertion line, we determined the shortest perpendicular distance to the middle of the fallopian canal, and from that "fallopian point" to the apex of the posterior process of the incus. We found good repeatability of measurements. We found the extended straight-into-cochlea insertion lines routinely close to or in the midst of the fallopian canal (50 % ≤ 1.0 mm). We found the lines 4.7-7.8 mm from the apex of the posterior process of the incus. Line positions relative to "fallopian point" and incus showed no relation to mastoid pneumatization. For the distance "fallopian point" to incus, bilateral symmetry was suggested. Using landmarks registered in an x-y-z coordinate system, straight-into-cochlea insertion via the round window puts the facial nerve at risk.

  11. Radiologic findings of deep seated cerebral arteriovenous malformation with nonvisualization of straight sinus: focused on angiogram

    International Nuclear Information System (INIS)

    Won, Jong Boo; Park, Sung Ho; Hong, Jong Won; Kim, Yoo Kyoung; Shin, Mi Jeong; Baik, Seung Kuk; Choi, Han Yong; Kim, Bong Gi

    1999-01-01

    To analyze the radiologic-especially angiographic-findings of deep seated cerebral arteriovenous malformation(AVM) involving nonvisualized straight sinus. In six patients aged between 15 and 53 years with deep seated cerebral AVM, CT and MR images were retrospectively analyzed with regard to the following features : the presence of straight sinus, the location of AVM, and the occurrence of hemorrhage. Angiograms were analyzed for venous drainage routes of AVM, the appearance of veins, the presence of falcine sinus and venous drainage from normal deep brain parenchyme. In four patients who had undergone intravascular embolization therapy, pre- and post- embolization angiograms were compared. CT and MR images showed neither straight sinus nor thrombosis. AVMs were deeply seated in the brain, and in all cases there was cerebral hemorrhage. Angiograms disclosed that venous drainage of all AVMs occurred via the veins of Galen. In one case, venous flow via the falcine sinus to the superior sagittal sinus was noted, but in others, retrograde flow in the deep venous system was observed. Marked collateral routes followed in response to the obstruction of straight sinus included the basal vein of Rosenthal, the internal occipital, internal cerebral, and cerebellar hemispheric veins (which are Galenic afferents), and the inferior sagittal sinus. In all patients, contralateral routes were partially involved. Venous drainage from normal deep parenchyme through the transcerebral veins to the superficial venous system was noted, and in one case, straight sinus which had been observed on an angiogram five years earlier was no longer present. Angiography offers effective evaluation of the dynamic aspect of venous flow in cases involving deep-seated AVM, and of normal deep parenchyme in cases in which AVM involves nonvisualized straight sinus. Before intravascular treatment of AVM, venous flow must be carefully analyzed

  12. Straight and chopped DC performance data for a reliance EV-250AT motor with a General Electric EV-1 controller

    Science.gov (United States)

    Edie, P. C.

    1981-01-01

    Straight and chopped DC motor performances for a Reliance EV-250AT motor with an EV-1 controller were examined. Effects of motor temperature and operating voltage are shown. It is found that the maximum motor efficiency is approximately 85% at low operating temperatures in the straight DC mode. Chopper efficiency is 95% under all operating conditions. For equal speeds, the motor operated in the chopped mode develops slightly more torque and draws more current than it does in the straight DC mode.

  13. Cubic systems with invariant affine straight lines of total parallel multiplicity seven

    Directory of Open Access Journals (Sweden)

    Alexandru Suba

    2013-12-01

    Full Text Available In this article, we study the planar cubic differential systems with invariant affine straight lines of total parallel multiplicity seven. We classify these system according to their geometric properties encoded in the configurations of invariant straight lines. We show that there are only 17 different topological phase portraits in the Poincar\\'e disc associated to this family of cubic systems up to a reversal of the sense of their orbits, and we provide representatives of every class modulo an affine change of variables and rescaling of the time variable.

  14. A potential flow 2-D vortex panel model: Applications to vertical axis straight blade tidal turbine

    International Nuclear Information System (INIS)

    Wang, L.B.; Zhang, L.; Zeng, N.D.

    2007-01-01

    A potential flow 2-D vortex panel model (VPM2D) for unsteady hydrodynamics calculation of the vertical axis straight blade variable pitch turbine was given for tidal streams energy conversion. Numerical results of predicted instantaneous blade forces and wake flow of the rotor showed good agreement with the test data. The model was also compared with the previous classic free vortex model (V-DART) and vortex method combined with finite element analysis (FEVDTM). It showed that the present model was much better than the former, less complex than the latter and suitable for designing and optimization of the vertical axis straight blade turbine

  15. Synthesis and characterization of straight and stacked-sheet AlN nanowires with high purity

    International Nuclear Information System (INIS)

    Lei, M.; Yang, H.; Li, P.G.; Tang, W.H.

    2008-01-01

    Large-scale AlN nanowires with hexagonal crystal structure were synthesized by the direct nitridation method at high temperatures. The experimental results indicate that these single-crystalline AlN nanowires have high purity and consist of straight and stacked-sheet nanowires. It is found that straight AlN nanowire grows along [1, 1, -2, 0] direction, whereas the stacked-sheet nanowire with hexagonal cross section is along [0 0 0 1] direction. It is thought that vapor-solid (VS) mechanism should be responsible for the growth of AlN nanowires

  16. The appearance potency of gay and straight men’s websites

    OpenAIRE

    Jankowski, G.; Slater, A.; Tiggemann, M.; Fawkner, H.

    2016-01-01

    Gay men's greater body dissatisfaction compared to straight men has been explained as a result of gay men’s more 'appearance potent' subculture. This study aimed to critically appraise this explanation by assessing images of men and women for their physical characteristics and objectification across 8 popular gay and straight men's dating and porn websites. 1,415 images of men and 715 images of women across the website’s main pages were coded. Results showed that the gay men's websites featur...

  17. The Planning of Straight Line Trajectory in Robotics Using Interactive Graphics

    Directory of Open Access Journals (Sweden)

    Kesheng Wang

    1987-07-01

    Full Text Available The planning of straight line trajectory using the interactive computer graphics simulation of robot manipulator movement is discussed. This new approach to straight line motion planning improves the 'bound deviation joint paths' developed by R. M. Taylor (1979. The new approach has three characteristics: (1 linear interpolation in joint space; (2 unequal intervals for interpolating knot points; (3 using interactive computer graphics to assure that the maximum deviation in the whole segment is less than the pre-specified values. The structure and mathematical basis of a computer program developed for this purpose are presented.

  18. Gender, Health Behavior, and Intimate Relationships: Lesbian, Gay, and Straight Contexts

    OpenAIRE

    Reczek, Corinne; Umberson, Debra

    2011-01-01

    Many studies focus on health behavior within the context of intimate ties. However, this literature is limited by reliance on gender socialization theory and a focus on straight (i.e., heterosexual) marriage. We extend this work with an analysis of relationship dynamics around health behavior in 20 long-term straight marriages as well as 15 gay and 15 lesbian long-term cohabiting partnerships in the United States (N=100 individual in-depth interviews). We develop the concept of “health behavi...

  19. Shielded transient self-interaction of a bunch entering a circle from a straight path

    International Nuclear Information System (INIS)

    Li, R.; Bohn, C.L.; Bisognano, J.J.

    1997-01-01

    When a short (mm-length) bunch with high (nC-regime) charge is transported through a magnetic bending system, self-interaction via coherent synchrotron radiation (CSR) and space charge may alter the bunch dynamics significantly. The authors consider a Gaussian rigid-line-charge bunch following a straight-path trajectory into a circle, with the trajectory centered between two infinite, parallel, perfectly conducting plates. Transients associated with CSR and space charge generated from source particles both on the straight path and the circle are calculated, and their net effect on the radiated power is contrasted with that of shielded steady-state CSR

  20. Design, construction and evaluation of solarized airlift tubular photobioreactor

    International Nuclear Information System (INIS)

    Bahadur, A; Zubair, M; Khan, M B

    2013-01-01

    An innovative photobioreactor is developed for growing algae in simulated conditions. The proposed design comprises of a continuous tubular irradiance loop and air induced liquid circulation with gas separation through air lift device. The unique features of air lift system are to ensure the shear free circulation of sensitive algal culture and induce light/dark cycles to the photosynthetic micro-organisms. The design strategy employs to model and construct a 20-liter laboratory scale unit using Boro-silicate glass tubing. The material is selected to ensure maximum photon transmission. All components of the device are designed to have flexibility to be replaced with an alternative design, providing fair chance of modification for future investigators. The principles of fluid mechanics are applied to describe geometrical attributes of the air lift system. Combination of LEDs and Florescent tube lights (Warm white) were used to illuminate the photosynthesis reaction area providing a possibility to control both illumination duration and light intensity. 200 Watt Solar PV system is designed to power up the device which included air pump (100 Watt) and illumination system (100 Watt). Algal strain Chlorella sp was inoculated in photobioreactor which was sparged with air and carbon dioxide. The growth was sustained in the batch mode with daily monitoring of temperature, pH and biomass concentration. The novel photobioreactor recorded a maximum experimental average yield of 0.65 g/l.day (11.3 g/m 2 .day) as compared to theoretical modeled yield of 0.82 g/l.day (14.26 g/m 2 .day), suggesting the device can be efficiently and cost-effectively employed in the production of algal biomass for biofuels, concomitantly mitigating CO 2 .

  1. Effect of air flow on tubular solar still efficiency.

    Science.gov (United States)

    Thirugnanasambantham, Arunkumar; Rajan, Jayaprakash; Ahsan, Amimul; Kandasamy, Vinothkumar

    2013-01-01

    An experimental work was reported to estimate the increase in distillate yield for a compound parabolic concentrator-concentric tubular solar still (CPC-CTSS). The CPC dramatically increases the heating of the saline water. A novel idea was proposed to study the characteristic features of CPC for desalination to produce a large quantity of distillate yield. A rectangular basin of dimension 2 m × 0.025 m × 0.02 m was fabricated of copper and was placed at the focus of the CPC. This basin is covered by two cylindrical glass tubes of length 2 m with two different diameters of 0.02 m and 0.03 m. The experimental study was operated with two modes: without and with air flow between inner and outer tubes. The rate of air flow was fixed throughout the experiment at 4.5 m/s. On the basis of performance results, the water collection rate was 1445 ml/day without air flow and 2020 ml/day with air flow and the efficiencies were 16.2% and 18.9%, respectively. THE EXPERIMENTAL STUDY WAS OPERATED WITH TWO MODES: without and with air flow between inner and outer tubes. The rate of air flow was fixed throughout the experiment at 4.5 m/s. On the basis of performance results, the water collection rate was 1445 ml/day without air flow and 2020 ml/day with air flow and the efficiencies were 16.2% and 18.9%, respectively.

  2. Relating porosity and mechanical properties in spray formed tubulars

    International Nuclear Information System (INIS)

    Payne, R.D.; Naval Surface Warfare Center, Annapolis, MD; Moran, A.L.; United States Naval Academy, Annapolis, MD; Cammarata, R.C.

    1993-01-01

    Because the spray forming process holds the potential to reduce the cost of alloy production, there is significant interest in developing methods to industrialized and automate this process through advanced sensing techniques. These advanced sensing techniques will observe the process real-time and give inputs to a process controller. By determining relationships between part quality, process parameters and sensor inputs, the process controller will be able to determine the quality of a part while it is being made and make adjustments if necessary. A Tinius-Olsen Tensile Tester was used to test five tensile specimens. The five tensile specimens were taken from five alloy 625 (60% Ni, 20% Cr, 8%Mo, 5% Fe) tubulars with varying properties. Among the advanced sensing techniques currently used to monitor the spray forming process is a surface roughness sensor. It consists of an argon laser, a charge coupled device (CCD) camera and roughness determination software. The laser emission is expanded into a long, thin line and projected onto the substrate as the molten metal consolidates on the surface. The roughness determination software will grab a frame with the laser stripe, digitize it and calculate the root mean square (RMS) value of the roughness in that particular frame. Each frame has a time stamp and can be related back to other time stamped process parameters. Recent sensor work has tried to find correlations between RMS values and porosities determined after processing. This venture has met with limited success. The object of this paper is to link porosity with mechanical properties and therefore define quality. Eventually the input from all sensors and process parameters will be entered into a process controller. If there is a link between sensor data and quality, this controller will be able to determine the quality of a forming material from sensor inputs and make changes in the process parameters if the quality is poor

  3. Analysis of a 3-phase tubular permanent magnet linear generator

    Energy Technology Data Exchange (ETDEWEB)

    Nor, K.M.; Arof, H.; Wijono [Malaya Univ., Kuala Lumpur (Malaysia). Faculty of Engineering

    2005-07-01

    A 3-phase tubular permanent linear generator design was described. The generator was designed to be driven by a single or a double 2-stroke combustion linear engine. Combustion took place alternately between 2 opposed chambers. In the single combustion engine, one of the combustion chambers was replaced by a kickback mechanism. The force on the translator generated by the explosion in the combustion chamber was used to compress the air in the kickback chamber. The pressed air was then used to release the stored energy to push back the translator in the opposite direction. The generator was modelled as a 2D object. A parametric simulation was performed to give a series of discrete data required to calculate machine electrical parameters; flux distribution; coil flux linkage; and, cogging force. Fringing flux was evaluated through the application of a magnetic boundary condition. The infinity boundary was used to include the zero electromagnetic potential in the surface boundary. A complete simulation was run for each step of the translator's motion, which was considered as sinusoidal. The simplification was further corrected using the real engine speed curve. The EMF was derived from the flux linkage difference in the coils at every consecutive translator position. Force was calculated in the translator and stator using a virtual work method. Optimization was performed using a subproblem strategy. It was concluded that the generator can be used to supply electric power as a stand-alone system, emergency power supply, or as part of an integrated system. 11 refs., 2 tabs., 10 figs.

  4. Urinary excretion of beta 2-glycoprotein-1 (apolipoprotein H) and other markers of tubular malfunction in "non-tubular" renal disease.

    Science.gov (United States)

    Flynn, F V; Lapsley, M; Sansom, P A; Cohen, S L

    1992-07-01

    To determine whether urinary beta 2-glycoprotein-1 assays can provide improved discrimination between chronic renal diseases which are primarily of tubular or glomerular origin. Urinary beta 2-glycoprotein-1, retinol-binding protein, alpha 1-microglobulin, beta 2-microglobulin, N-acetyl-beta-D-glucosa-minidase and albumin were measured in 51 patients with primary glomerular disease, 23 with obstructive nephropathy, and 15 with polycystic kidney disease, and expressed per mmol of creatinine. Plasma beta 2-glycoprotein-1 was assayed in 52 patients and plasma creatinine in all 89. The findings were compared between the diagnostic groups and with previously published data relating to primary tubular disorders. All 31 patients with plasma creatinine greater than 200 mumol/l excreted increased amounts of beta 2-glycoprotein-1, retinol-binding protein, and alpha 1-microglobulin, and 29 had increased N-acetyl-beta-D-glucosaminidase; the quantities were generally similar to those found in comparable patients with primary tubular pathology. Among 58 with plasma creatinine concentrations under 200 mumol/l, increases in beta 2-glycoprotein-1, retinol-binding protein, and alpha 1-microglobulin excretion were less common and much smaller, especially in those with obstructive nephropathy and polycystic disease. The ratios of the excretion of albumin to the other proteins provided the clearest discrimination between the patients with glomerular or tubular malfunction, but an area of overlap was present which embraced those with obstructive nephropathy and polycystic disease. Increased excretion of beta 2-glycoprotein-1 due to a raised plasma concentration or diminution of tubular reabsorption, or both, is common in all the forms of renal disease investigated, and both plasma creatinine and urinary albumin must be taken into account when interpreting results. Ratios of urinary albumin: beta 2-glycoprotein-1 greater than 1000 are highly suggestive of primary glomerular disease and

  5. Microstructure and mechanical properties of AZ91 tubes fabricated by Multi-pass Parallel Tubular Channel Angular Pressing

    OpenAIRE

    Hooman Abdolvand; Ghader Faraji; Javad Shahbazi Karami

    2017-01-01

    Parallel Tubular Channel Angular Pressing (PTCAP) process is a novel recently developed severe plastic deformation (SPD) method for producing ultrafine grained (UFG) and nanograined (NG) tubular specimens with excellent mechanical and physical properties. This process has several advantageous compared to its TCAP counterparts. In this paper, a fine grained AZ91 tube was fabricated via multi pass parallel tubular channel angular pressing (PTCAP) process. Tubes were processed up to three passes...

  6. Support and tool displacement device for the attachment of a tube bundle on a tubular plate of a steam generator

    International Nuclear Information System (INIS)

    Morisot, M.; Werle, R.; Michaud, J.P.

    1983-01-01

    The steam generator is being assembled, disposed with its axis horizontal and its tubular plate vertical; the device described in this patent, allows to automatize the preparation stages of the tubular plate and the attachment of the bundle, to shorten the construction of the steam generator and to remove drudgeries done by hand on the tubular plate or the tubes of the bundle. The invention can be applied to the construction of PWR steam generators [fr

  7. Darboux integrability and rational reversibility in cubic systems with two invariant straight lines

    Directory of Open Access Journals (Sweden)

    Dumitru Cozma

    2013-01-01

    Full Text Available We find conditions for a singular point O(0,0 of a center or a focus type to be a center, in a cubic differential system with two distinct invariant straight lines. The presence of a center at O(0,0 is proved by using the method of Darboux integrability and the rational reversibility.

  8. Understanding the Active Straight Leg Raise (ASLR): An electromyographic study in healthy subjects

    NARCIS (Netherlands)

    Hu, H.; Meijer, O.G.; Bruijn, S.M.; Strijers, R.L.M.; Nanayakkara, P.W.B.; van Royen, B.J.; Wu, W; Xia, C.; van Dieen, J.H.

    2012-01-01

    The Active Straight Leg Raise (ASLR) is an important test in diagnosing pelvic girdle pain (PGP). It is difficult to understand what happens normally during the ASLR, let alone why it would be impaired in PGP. In the present study, healthy subjects performed the ASLR under normal conditions, with

  9. MORPION: a fast hardware processor for straight line finding in MWPC

    International Nuclear Information System (INIS)

    Mur, M.

    1980-02-01

    A fast hardware processor for straight line finding in MWPC has been built in Saclay and successfully operated in the NA3 experiment at CERN. We give the motivations to build this processor, and describe the hardware implementation of the line finding algorithm. Finally its use and performance in NA3 are described

  10. Straight-line assimilation in home-leaving? A comparison of Turks, Somalis and Danes

    DEFF Research Database (Denmark)

    Nielsen, Rikke Skovgaard

    2016-01-01

    The purpose of this paper is to test the evidence for spatial assimilation and straight-line assimilation in the transition of leaving home in Denmark. Based on data from the extensive Danish registers, the paper analyses the home-leaving patterns of Danes, Turkish immigrants, Turkish descendants...

  11. Straight-leg rasing in 'short hamstrings'. An experimental study of muscle elasticy and defense reactions.

    NARCIS (Netherlands)

    Göeken, Ludwig Nanno Hiltjo

    1988-01-01

    The central guestion asked in this thesis is whether an Experimental Straight-Leg Raising test (E.S.L.R.) can contribute to the solution of a diagnostical problem frequently encountered in rehabilitation medicine. It concerns the determination of the cause of the movement restriction in patients who

  12. Effect of Hartmann layer resolution for MHD flow in a straight ...

    Indian Academy of Sciences (India)

    851–861. c Indian Academy of Sciences. Effect of Hartmann layer resolution for MHD flow in a straight, conducting duct at high Hartmann numbers. SHARANYA SUBRAMANIAN1,∗, P K SWAIN2,. A V DESHPANDE1 and P SATYAMURTHY2. 1Mechanical Engineering Department, Veermata Jijabai Technological Institute,.

  13. Pre-School Students' Informal Acquisitions Regarding the Concepts of Point and Straight Line

    Science.gov (United States)

    Orbay, Keziban; Develi, Mehmet Hikmet

    2015-01-01

    This study aimed to investigate the informal cognitive structures regarding "point" and "straight line"--two basic and undefined terms of geometry--in children registered in preschool--the previous step before in-class formal education process. The study was conducted with the participation of 50 children enrolled in nursery,…

  14. Straight A's: Public Education Policy and Progress. Volume 12, Number 2

    Science.gov (United States)

    Amos, Jason, Ed.

    2012-01-01

    "Straight A's: Public Education Policy and Progress" is a biweekly newsletter that focuses on education news and events both in Washington, DC and around the country. The following articles are included in this issue: (1) Waiving Away High School Graduation Rate Accountability?: State NCLB Waiver Proposals Threaten to Weaken…

  15. Straight A's: Public Education Policy and Progress. Volume 12, Number 7

    Science.gov (United States)

    Amos, Jason, Ed.

    2012-01-01

    "Straight A's: Public Education Policy and Progress" is a biweekly newsletter that focuses on education news and events both in Washington, DC and around the country. The following articles are included in this issue: (1) Problems Down the Road: House Passes Congressional Budget Resolutions, Sets Overall Spending Cap at $19 Billion Below Senate;…

  16. A Program Review of a Middle School Gay-Straight Alliance Club

    Science.gov (United States)

    Quasha, Scott; McCabe, Paul C.; Ortiz, Samuel O.

    2014-01-01

    This program review examined a middle school Gay-Straight Alliance (GSA) club within a northeastern suburban school situated in a large metropolitan area. The GSA was the first in the region to start exclusively in a standalone middle school. The review was accomplished through a staff survey comparing school climates for lesbian, gay, bisexual,…

  17. Destabilizing Anti-Gay Environments through Gay-Straight Alliances: Possibilities and Limitations through Shifting Discourses

    Science.gov (United States)

    Currie, Sean; Mayberry, Maralee; Chenneville, Tiffany

    2012-01-01

    Drawing upon research with Gay-Straight Alliance (GSA) advisors, high-school principals, and two district-level administrators, we examine the potential and limits of the safe-space discourse that encompasses the aims of GSAs. We argue that this discourse conceals heteronormative school environments, which supplies the groundwork for hostility…

  18. Perceptions of a Gay-Straight Alliance Club Ban: School Counselors and Advocacy for LGBTQQ Students

    Science.gov (United States)

    Lassiter, Pamela S.; Sifford, Amy McCarthy

    2015-01-01

    This phenomenological inquiry explored the experiences and reactions of five school counselors who worked in a school that banned a Gay-Straight Alliance club. Specifically, the authors examined how counselors' perceptions of the ban influenced their advocacy for LGBTQQ students. The results of semi-structured interviews revealed one overarching…

  19. Accounting for straight parts effects on elbow's flexibilities in a beam type finite element program

    International Nuclear Information System (INIS)

    Millard, A.

    1983-01-01

    An extension of Von Karman's theory is applied to the calculations of the flexibility factor of a pipe bend terminated by a straight part or a flange. This analysis is restricted to the linear elastic deformation behaviour under in plane bending. Analytical solutions are given for the propagation of ovalization in the elbow and in the straight part. Considering the response of the piping structures, we note that the ovalization of the piping systems are reduced significantly when the straight parts or flanges effects are included. This results are presented in terms of global as well local flexibility factors. They have been compared to numerical results obtained by shell type finite elements method. A complete piping system is analyzed, for economical reasons, with a beam type approach. Also, we show how it is possible to take into account an elbow's flexibilities the straight parts effects by means of flexibilities factors introduced in a beam type elements. We have implemented this method in the computer program TEDEL. In some specific geometrical features, we compare solutions using shell type elements and our formulation. (orig.)

  20. Effects of cavity on leakage loss in straight-through labyrinth seals

    International Nuclear Information System (INIS)

    Zhao, W; Nielsen, T K; Billdal, J T

    2010-01-01

    Labyrinth seals are widely used in rotating fluid machinery, due to its low-cost, simplicity and reliability. A straight-through labyrinth seal consists of a clearance between the stator and rotor, and sometimes cavities which are included on the stator or the rotator side. In this type of seals, making cavities are an effective way to convert turbulence kinetic energy into thermal energy by forming turbulence vortices, thereby reducing pressure difference and leakage flow. In this paper, the effect of cavities on leakage loss in straight-through labyrinth seals are studied by changing cavity dimensions such as depth and length, cavity number and cavity location. The influences of unilateral cavities and bilateral cavities on the leakage loss in straight-through labyrinth seals are also compared. The fluid flow characteristics through straight-through labyrinth seals were obtained by using viscous flow analysis along with a standard k-ωturbulence model. The cavity dimensions and cavity numbers have significant effects on the leakage as well as on the flow pattern in the seal. The bilateral cavity has better leakage performance than the unilateral cavity when cavity dimensions are identical. However, the cavity location shows no significant influences on the leakage flow.

  1. Making Schools Safe and Inclusive: Gay-Straight Alliances and School Climate in Ontario

    Science.gov (United States)

    Kitchen, Julian; Bellini, Christine

    2013-01-01

    Gay-straight alliances (GSAs) have become widespread in Ontario schools and, starting in 2012, all schools are required to permit students to form GSAs. While American research suggests that GSAs have a positive impact on school safety and inclusion, there is little research on the impact of GSAs in Canadian schools. This study, based on a survey…

  2. Duration of load behaviour of different sized straight timber beams subjected to bending in variable climate

    DEFF Research Database (Denmark)

    Hanhijärvi, A.; Galimard, P.; Hoffmeyer, Preben

    1998-01-01

    The paper is the second in a series which sums up the results of an extensive project to quantify the duration-of-load (DOL) effect on different sized timber beams in different climates. The paper deals with straight (unnotched) beams. The results of various DOL-tests of stepwise and constant...

  3. Cherry Picking: Virginity Loss Definitions Among Gay and Straight Cisgender Men.

    Science.gov (United States)

    Huang, Howard

    2017-08-03

    Virginity loss is a vital milestone in the development of one's sexual identity. Unfortunately, there is very little literature available studying virginity loss definitions among the wider straight population, and even less examining virginity loss among LGBTQ+ populations. The present study recruited 251 (45.4%) cisgender straight men and 114 (54.6%) cisgender gay men. An online, anonymous survey was administered to explore whether they considered various male-on-male (M-M) and male-on-female (M-F) sexual behaviors as constitutive of virginity loss. Results indicate that more gay men than straight considered M-M receptive anal intercourse (i.e., bottoming) and M-F penetrative anal intercourse to be constitutive of virginity loss. Results also indicate that both gay and straight men almost unanimously endorsed M-F penovaginal sex to be constitutive of virginity loss. This study is a first-step toward gaining a better understanding of LGBTQ+ virginity loss conceptualizations. Future research is strongly encouraged.

  4. Accounting for straight parts effects on elbow's flexibilities in a beam type finite element program

    International Nuclear Information System (INIS)

    Millard, A.; Vaghi, H.; Ricard, A.

    1983-08-01

    An extension of Von Karman's theory is applied to the calculations of the flexibility factor of a pipe bend terminated by a straight part or a flange. This analysis is restricted to the linear elastic deformation behaviour under in plane bending. Analytical solutions are given for the propagation of ovalization in the elbow and in the straight part. Considering the response of the piping structures, we note that the ovalization of the piping systems are reduced significantly when the straight parts or flanges effects are included. The results are presented in terms of global as well local flexibility factors. They have been compared to numerical results obtained by shell type finite element method. A complete piping system is analyzed, for economical reasons, with a beam type approach. Also, we show how it is possible to take into account on elbow's flexibilities the straight parts effects by means of flexibilities factors introduced in a beam type element. We have implemented this method in the computer program TEDEL. In some specific geometrical features, we compare solutions using shell type elements and our formulation

  5. Bed shear stress distribution in straight channels with arbitrary cross section

    DEFF Research Database (Denmark)

    Christensen, Henrik Bo; Fredsøe, Jørgen

    1998-01-01

    The bed shear stress distribution in straight open channels is affected by mechanisms as bed curvature of the cross section profile, shear diffusion, and secondary currents. This paper compares some analytical and numerical methods to estimate the bed shear stress distribution. The methods...

  6. Straight A's: Public Education Policy and Progress. Volume 12, Number 9

    Science.gov (United States)

    Amos, Jason, Ed.

    2012-01-01

    "Straight A's: Public Education Policy and Progress" is a biweekly newsletter that focuses on education news and events both in Washington, DC and around the country. The following articles are included in this issue: (1) You Take the High Road and I'll Take the Low Road: As Appropriations Process Begins, Different Spending Approaches Likely to…

  7. Gay-Straight Alliances in the Battle for Rights: A Tipping Point for Progress over Prohibition

    Science.gov (United States)

    Sinclair, James; Reece, Brian J.

    2016-01-01

    This is a brief essay on the oppressive natures of school and the rights of students to arm themselves with the creation of Gay-Straight Alliances (GSAs). Students who identify as LGBTQ are at higher risk for victimization, among other negative outcomes. For those who identify as LGBTQ, GSAs are often a safe-haven from the heteronormative…

  8. Comparison of coupled mode theory and FDTD simulations of coupling between bent and straight optical waveguides

    NARCIS (Netherlands)

    Bertolotti, M.; Symes, W.W.; Stoffer, Remco; Hiremath, K.R.; Driessen, A.; Michelotti, F; Hammer, Manfred

    Analysis of integrated optical cylindrical microresonators involves the coupling between a straight waveguide and a bent waveguide. Our (2D) variant of coupled mode theory is based on analytically represented mode profiles. With the bend modes expressed in Cartesian coordinates, coupled mode

  9. Design and Validation of a Straight-Copy Typewriting Prognostic Test Using Kinesthetic Sensitivity.

    Science.gov (United States)

    Olson, Norma Jean

    1979-01-01

    Describes the development and application of a kinesthetic sensitivity test to determine whether it is a valid and reliable measure of straight-copy typing speed and accuracy. The author states that this kinesthetic sensitivity instrument may be used as a prognostic aptitude test and recommends administration methods. (MF)

  10. Trends in Canadian Newspaper Coverage of Gay-Straight Alliances, 2000-2009

    Science.gov (United States)

    Herriot, Lindsay

    2011-01-01

    Gay-straight alliances (GSAs) in Canadian public schools have gained considerable attention from print media since reports first surfaced in the year 2000. This study tracked and analyzed Canadian newspaper reporting about GSA creation. It summarized the shift in public opinion toward lesbian, gay, bisexual, transgender, and queer (LGBTQ) youth…

  11. Gender, health behavior, and intimate relationships: lesbian, gay, and straight contexts.

    Science.gov (United States)

    Reczek, Corinne; Umberson, Debra

    2012-06-01

    Many studies focus on health behavior within the context of intimate ties. However, this literature is limited by reliance on gender socialization theory and a focus on straight (i.e., heterosexual) marriage. We extend this work with an analysis of relationship dynamics around health behavior in 20 long-term straight marriages as well as 15 gay and 15 lesbian long-term cohabiting partnerships in the United States (N = 100 individual in-depth interviews). We develop the concept of "health behavior work" to align activities done to promote health behavior with theories on unpaid work in the home. Respondents in all couple types describe specialized health behavior work, wherein one partner works to shape the other partner's health behavior. In straight couples, women perform the bulk of specialized health behavior work. Most gay and lesbian respondents-but few straight respondents--also describe cooperative health behavior work, wherein partners mutually influence one another's health behaviors. Findings suggest that the gendered relational context of an intimate partnership shapes the dynamics of and explanations for health behavior work. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Greater Engagement among Members of Gay-Straight Alliances: Individual and Structural Contributors

    Science.gov (United States)

    Poteat, V. Paul; Heck, Nicholas C.; Yoshikawa, Hirokazu; Calzo, Jerel P.

    2016-01-01

    Using youth program models to frame the study of Gay-Straight Alliances (GSAs), we identified individual and structural predictors of greater engagement in these settings with a cross-sectional sample of 295 youth in 33 GSAs from the 2014 Massachusetts GSA Network Survey (69% LGBQ, 68% cisgender female, 68% White, M[subscript age] =16.07).…

  13. Optimizing the injection straight of PEP II asymmetric B Factory at SLAC

    International Nuclear Information System (INIS)

    Bulos, F.; Bloom, E.; Davies-White, W.; Donald, M.; Fairfield, K.; Fieguth, T.; Godfrey, G.; Holtzapple, R.; Hutton, A.; Loew, G.; Miller, R.; Sukiennicki, B.; Wen, H.; Ronan, M.

    1992-04-01

    The asymmetric energy PEP II B Factory proposed as an upgrade of PEP at the Stanford Linear Accelerator Center requires both a powerful low emittance source of e - e + and a very reliable and efficient injection system. The SLC linac fulfills the source requirement very well. We describe here the optimization of the optics of the injection straight to insure reliable and efficient injection

  14. Straight vegetable oils usage in a compression ignition engine - A review

    Energy Technology Data Exchange (ETDEWEB)

    Misra, R.D.; Murthy, M.S. [Mechanical Engineering Department, National Institute of Technology, Silchar 788010, Assam (India)

    2010-12-15

    The ever increasing fossil fuel usage and cost, environmental concern has forced the world to look for alternatives. Straight vegetable oils in compression ignition engine are a ready solution available, however, with certain limitations and with some advantages as reported by many researchers. A comprehensive and critical review is presented specifically pertaining to straight vegetable oils usage in diesel engine. A detailed record of historical events described. Research carried out specifically under Indian conditions and international research work on the usage of straight vegetable oils in the diesel engine is separately reviewed. Many researchers have reported that straight vegetable oils in small percentage blends with diesel when used lower capacity diesel engines have shown great promise with regards to the thermal performance as well exhaust emissions. This has been explained in detail. Finally based on the review of international as well as Indian research a SWOT analysis is carried out. The review concludes that there is still scope for research in this area. (author)

  15. Straight chiropractic philosophy as a barrier to Medicare compliance: a discussion of 5 incongruent issues.

    Science.gov (United States)

    Seaman, David R; Soltys, Jonathan R

    2013-12-01

    The purpose of this commentary is to discuss potential 5 factors within straight chiropractic philosophy and practice that may prevent Medicare compliance. The national Medicare Benefit Policy Manual and the Florida Local Coverage Determination were reviewed to identify documentation and conceptual issues regarding chiropractic practice. Five Medicare positions were contrasted with tenets of straight chiropractic philosophy. Based on Medicare's documentation requirements, Medicare defines subluxation and chiropractic practice from the perspective of treating spinal pain and related functional disability. In contrast, traditional straight chiropractic philosophy is not based on the treatment of spinal pain and disability or other symptomatic presentations. In this context, 5 potential areas of conflict are discussed. The Medicare version of chiropractic practice is not consistent with traditional straight chiropractic philosophy, which may play a role in preventing Medicare compliance. The chiropractic profession may need to consider the fashion in which "philosophy" as it relates to technique and practice is presented to students and doctors to facilitate compliance with the documentation requirements of Medicare.

  16. Straight A's: Public Education Policy and Progress. Volume 6, Number 2

    Science.gov (United States)

    Amos, Jason, Ed.

    2006-01-01

    "Straight A's: Public Education Policy and Progress" is a biweekly newsletter that focuses on education news and events both in Washington, DC and around the country. The following articles are included in this issue: (1) State of American Business: U.S. Chamber of Commerce Says U.S. Could Face a "Severe Worker Shortage" Unless…

  17. Optimizing the injection straight of PEP II asymmetric B factory at SLAC

    International Nuclear Information System (INIS)

    Bulos, F.; Bloom, E.; Davies-White, W.; Donald, M.; Fairfield, K.; Fieguth, T.; Godfrey, G.; Holtzapple, R.; Hutton, A.; Loew, G.; Miller, R.; Sukiennicki, B.; Wen, H.

    1992-01-01

    The asymmetric energy PEP II B Factory proposed as an upgrade of PEP at the Stanford Linear Accelerator Center requires both a powerful low emittance source of e - e + and a very reliable and efficient injection system. The SLC linac fulfills the source requirement very well. We describe here the optimization of the optics of the injection straight to insure reliable and efficient injection

  18. Offsetting Risks: High School Gay-Straight Alliances and Lesbian, Gay, Bisexual, and Transgender (LGBT) Youth

    Science.gov (United States)

    Heck, Nicholas C.; Flentje, Annesa; Cochran, Bryan N.

    2011-01-01

    Lesbian, gay, bisexual, and transgender (LGBT) youth are at risk for engaging in negative health behaviors and for experiencing at-school victimization. Specific benefits of attending a high school with a gay-straight alliance (GSA), including lower levels of suicidality, have been published; however, it is unclear whether GSAs are related to…

  19. Demographic Trends and Advocacy Experiences of Gay-Straight Alliance Advisors

    Science.gov (United States)

    Graybill, Emily C.; Varjas, Kris; Meyers, Joel; Dever, Bridget V.; Greenberg, Daphne; Roach, Andrew T.; Morillas, Catalina

    2015-01-01

    Using an ecological model, the individual-, school-, and sociocultural-level characteristics that affect gay-straight alliance (GSA) advisors were examined in the current study. The formation of GSAs has been one way that schools have sought to improve the school climate for lesbian, gay, bisexual, and transgender (LGBT) youth. Limited information…

  20. Curved-straight neutron guide system with uniform spatial intensity distribution

    International Nuclear Information System (INIS)

    Mildner, D.F.R.; Cook, J.C.

    2008-01-01

    The spatial intensity distribution of neutrons emerging from a curved guide is asymmetric, and straight guide sections are sometimes appended to curved guides to make the intensity distribution more nearly uniform. For idealized uniform illumination and in the perfect reflectivity approximation, the spatial-angular acceptance at the exit of the combination can be made exactly uniform for a range of long wavelengths by using a sufficiently long straight section, together with a curved guide whose outer wall coating has a critical angle slightly greater than those of the other guide walls. We refer to this as a 'phase space tailoring guide' where the coatings on the inner wall and straight section are used to define the required divergence at the end of the guide. Increasing the critical angle of the outer wall of the curved section reduces the characteristic wavelength of the curved guide as well as the wavelength at which ideal uniformity can be obtained. The outer wall coating need only be of sufficiently high critical angle to fill the transmittable phase space area of the straight guide uniformly to adequately short wavelength

  1. Use of Straight –Run Gasoline (Srg) as A Leaching Solvent for Oil ...

    African Journals Online (AJOL)

    A study was conducted on the use of straight-run gasoline (SRG) as an extraction solvent for the leaching of palm kernel to produce palm kernel oil (PKO). SRG is an intermediate product fraction in the second fraction of crude petroleum oil fractionation that has not undergone any purification process. It is intended as a ...

  2. Charged Particle Dynamics in the Magnetic Field of a Long Straight Current-Carrying Wire

    Science.gov (United States)

    Prentice, A.; Fatuzzo, M.; Toepker, T.

    2015-01-01

    By describing the motion of a charged particle in the well-known nonuniform field of a current-carrying long straight wire, a variety of teaching/learning opportunities are described: 1) Brief review of a standard problem; 2) Vector analysis; 3) Dimensionless variables; 4) Coupled differential equations; 5) Numerical solutions.

  3. Morbidity Following Coloanal Anastomosis: A Comparison of Colonic J-Pouch vs Straight Anastomosis.

    Science.gov (United States)

    Brown, Shaun; Margolin, David A; Altom, Laura K; Green, Heather; Beck, David E; Kann, Brian R; Whitlow, Charles B; Vargas, Herschel David

    2018-02-01

    Low rectal tumors are often treated with sphincter-preserving resection followed by coloanal anastomosis. The purpose of this study was to compare the short-term complications following straight coloanal anastomosis vs colonic J-pouch anal anastomosis. Patients were identified who underwent proctectomy for rectal neoplasia followed by coloanal anastomosis in the 2008 to 2013 American College of Surgeons National Surgical Quality Improvement Program database. Demographic characteristics and 30-day postoperative complications were compared between groups. A national sample was extracted from the American College of Surgeons National Surgical Quality Improvement Project database. Inpatients following proctectomy and coloanal anastomosis for rectal cancer were selected. Demographic characteristics and 30-day postoperative complications were compared between the 2 groups. One thousand three hundred seventy patients were included, 624 in the straight anastomosis group and 746 in the colonic J-pouch group. Preoperative characteristics were similar between groups, with the exception of preoperative radiation therapy (straight anastomosis 35% vs colonic J-pouch 48%, p = 0.0004). Univariate analysis demonstrated that deep surgical site infection (3.7% vs 1.4%, p = 0.01), septic shock (2.25% vs 0.8%, p = 0.04), and return to the operating room (8.8% vs 5.0%, p = 0.0006) were more frequent in the straight anastomosis group vs the colonic J-pouch group. Major complications were also higher (23% vs 14%, p = 0.0001) and length of stay was longer in the straight anastomosis group vs the colonic J-pouch group (8.9 days vs 8.1 days, p = 0.02). After adjusting for covariates, major complications were less following colonic J-pouch vs straight anastomosis (OR, 0.57; CI, 0.38-0.84; p = 0.005). Subgroup analysis of patients who received preoperative radiation therapy demonstrated no difference in major complications between groups. This study had those limitations inherent to a

  4. Osteomalacia complicating renal tubular acidosis in association with Sjogren's syndrome.

    Science.gov (United States)

    El Ati, Zohra; Fatma, Lilia Ben; Boulahya, Ghada; Rais, Lamia; Krid, Madiha; Smaoui, Wided; Maiz, Hedi Ben; Beji, Soumaya; Zouaghi, Karim; Moussa, Fatma Ben

    2014-09-01

    Renal involvement in Sjogren's syndrome (SS) is not uncommon and may precede other complaints. Tubulointerstitial nephritis is the most common renal disease in SS and may lead to renal tubular acidosis (RTA), which in turn may cause osteomalacia. Nevertheless, osteomalacia rarely occurs as the first manifestation of a renal tubule disorder due to SS. We herewith describe a 43-year-old woman who was admitted to our hospital for weakness, lumbago and inability to walk. X-ray of the long bones showed extensive demineralization of the bones. Laboratory investigations revealed chronic kidney disease with serum creatinine of 2.3 mg/dL and creatinine clearance of 40 mL/min, hypokalemia (3.2 mmol/L), hypophosphatemia (0.4 mmol/L), hypocalcemia (2.14 mmol/L) and hyperchloremic metabolic acidosis (chlorine: 114 mmol/L; alkaline reserve: 14 mmol/L). The serum alkaline phosphatase levels were elevated. The serum levels of 25-hydroxyvitamin D and 1,25-dihydroxy vitamin D were low and borderline low, respectively, and the parathyroid hormone level was 70 pg/L. Urinalysis showed inappropriate alkaline urine (urinary PH: 7), glycosuria with normal blood glucose, phosphaturia and uricosuria. These values indicated the presence of both distal and proximal RTA. Our patient reported dryness of the mouth and eyes and Schirmer's test showed xerophthalmia. An accessory salivary gland biopsy showed changes corresponding to stage IV of Chisholm and Masson score. Kidney biopsy showed diffuse and severe tubulo-interstitial nephritis with dense lymphoplasmocyte infiltrates. Sicca syndrome and renal interstitial infiltrates indicated SS as the underlying cause of the RTA and osteomalacia. The patient received alkalinization, vitamin D (Sterogyl ®), calcium supplements and steroids in an initial dose of 1 mg/kg/day, tapered to 10 mg daily. The prognosis was favorable and the serum creatinine level was 1.7 mg/dL, calcium was 2.2 mmol/L and serum phosphate was 0.9 mmol/L.

  5. Tumor-promoting phorbol esters effect alkalinization of canine renal proximal tubular cells

    International Nuclear Information System (INIS)

    Mellas, J.; Hammerman, M.R.

    1986-01-01

    We have demonstrated the presence of specific receptors for tumor-promoting phorbol esters in the plasma membrane of the canine renal proximal tubular cell. These compounds affect proximal tubular metabolism in vitro. For example, we have shown that they inhibit gluconeogenesis in canine renal proximal tubular segments. Tumor-promoting phorbol esters have been shown to effect alkalinization of non-renal cells, by enhancing Na + -H + exchange across the plasma membrane. To determine whether the actions of tumor-promoting phorbol esters in proximal tubular segments might be mediated by a similar process, we incubated suspensions of segments from dog kidney with these compounds and measured changes in intracellular pH using [ 14 C]-5,5-dimethoxazoladine-2-4-dione (DMO) and flow dialysis. Incubation of segments with phorbol 12,13 dibutyrate, but not inactive phorbol ester, 4 γ phorbol, effected alkalinization of cells within the segments in a concentration-dependent manner. Alkalinization was dependent upon the presence of extracellular [Na + ] > intracellular [Na + ], was prevented by amiloride and was demonstrable in the presence of SITS. Our findings suggest that tumor-promoting esters stimulate the Na + -H + exchanger known to be present in the brush border membrane of the renal proximal tubular cell. It is possible that the stimulation reflects a mechanism by which phorbol esters affect metabolic processes in these cells

  6. Polydopamine-coated open tubular column for the separation of proteins by capillary electrochromatography.

    Science.gov (United States)

    Xiao, Xing; Wang, Wentao; Chen, Jia; Jia, Li

    2015-08-01

    The separation and determination of proteins in food is an important aspect in food industry. Inspired by the self-polymerization of dopamine under alkaline conditions and the natural adhesive properties of polydopamine, in this paper, a simple and economical method was developed for the preparation of polydopamine-coated open tubular column, in which ammonium persulfate was used as the source of oxygen to induce and facilitate the polymerization of dopamine to form polydopamine. In comparison with a naked fused-silica capillary, the direction and magnitude of the electro-osmotic flow of the as-prepared polydopamine-coated open tubular column could be manipulated by varying the pH values of background solutions due to the existence of amine and phenolic hydroxyl groups on polydopamine coating. The surface morphology of the polydopamine-coated open tubular column was studied by scanning electron microscopy, and the thickness of polydopamine coating was 106 nm. The performance of the polydopamine-coated open tubular column was validated by analysis of proteins. The relative standard deviations of migration times of proteins representing run-to-run, day-to-day, and column-to-column were less than 3.5%. In addition, the feasibility of the polydopamine-coated open tubular column for real samples was verified by the separation of proteins in chicken egg white and pure milk. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. The Tubular Penetration Depth and Adaption of Four Sealers: A Scanning Electron Microscopic Study

    Directory of Open Access Journals (Sweden)

    Huan Chen

    2017-01-01

    Full Text Available Background. The tubular penetration and adaptation of the sealer are important factors for successful root canal filling. The aim of this study was to evaluate the tubular penetration depth of four different sealers in the coronal, middle, and apical third of root canals as well as the adaptation of these sealers to root canal walls. Materials and Methods. 50 single-rooted teeth were prepared in this study. Forty-eight of them were filled with different sealers (Cortisomol, iRoot SP, AH-Plus, and RealSeal SE and respective core filling materials. Then the specimens were sectioned and scanning electron microscopy was employed to assess the tubular penetration and adaptation of the sealers. Results. Our results demonstrated that the maximum penetration was exhibited by RealSeal SE, followed by AH-Plus, iRoot SP, and Cortisomol. As regards the adaptation property to root canal walls, AH-Plus has best adaptation capacity followed by iRoot SP, RealSeal SE, and Cortisomol. Conclusion. The tubular penetration and adaptation vary with the different sealers investigated. RealSeal SE showed the most optimal tubular penetration, whereas AH-Plus presented the best adaptation to the root canal walls.

  8. In vivo antibody-mediated modulation of aminopeptidase A in mouse proximal tubular epithelial cells.

    Science.gov (United States)

    Mentzel, S; Dijkman, H B; van Son, J P; Wetzels, J F; Assmann, K J

    1999-07-01

    Aminopeptidase A (APA) is one of the many renal hydrolases. In mouse kidney, APA is predominantly expressed on the brush borders and sparsely on the basolateral membranes of proximal tubular epithelial cells. However, when large amounts of monoclonal antibodies (MAbs) against APA were injected into mice, we observed strong binding of the MAbs to the basolateral membranes, whereas the MAbs bound only transiently to the brush borders of the proximal tubular epithelial cells. In parallel, APA itself disappeared from the brush borders by both endocytosis and shedding, whereas it was increasingly expressed on the basolateral sides. Using ultrastructural immunohistology, we found no evidence for transcellular transport of endocytosed APA to the basolateral side of the proximal tubular epithelial cells. The absence of transcellular transport was confirmed by experiments in which we used a low dose of the MAbs. Such a low dose did not result in binding of the MAbs to the brush borders and had no effect on the presence of APA in the brush borders of the proximal tubular epithelial cells. In these experiments we still could observe binding of the MAbs to the basolateral membranes in parallel with the local appearance of APA. In addition, treatment of mice with chlorpromazine, a calmodulin antagonist that interferes with cytoskeletal function, largely inhibited the MAb-induced modulation of APA. Our studies suggest that injection of MAbs to APA specifically interrupts the normal intracellular traffic of this enzyme in proximal tubular epithelial cells. This intracellular transport is dependent on the action of cytoskeletal proteins.

  9. Head and pelvic movement asymmetry during lungeing in horses with symmetrical movement on the straight.

    Science.gov (United States)

    Rhodin, M; Roepstorff, L; French, A; Keegan, K G; Pfau, T; Egenvall, A

    2016-05-01

    Lungeing is commonly used as part of standard lameness examinations in horses. Knowledge of how lungeing influences motion symmetry in sound horses is needed. The aim of this study was to objectively evaluate the symmetry of vertical head and pelvic motion during lungeing in a large number of horses with symmetric motion during straight line evaluation. Cross-sectional prospective study. A pool of 201 riding horses, all functioning well and considered sound by their owners, were evaluated in trot on a straight line and during lungeing to the left and right. From this pool, horses with symmetric vertical head and pelvic movement during the straight line trot (n = 94) were retained for analysis. Vertical head and pelvic movements were measured with body mounted uniaxial accelerometers. Differences between vertical maximum and minimum head (HDmax, HDmin) and pelvic (PDmax, PDmin) heights between left and right forelimb and hindlimb stances were compared between straight line trot and lungeing in either direction. Vertical head and pelvic movements during lungeing were more asymmetric than during trot on a straight line. Common asymmetric patterns seen in the head were more upward movement during push-off of the outside forelimb and less downward movement during impact of the inside limb. Common asymmetric patterns seen in the pelvis were less upward movement during push-off of the outside hindlimb and less downward movement of the pelvis during impact of the inside hindlimb. Asymmetric patterns in one lunge direction were frequently not the same as in the opposite direction. Lungeing induces systematic asymmetries in vertical head and pelvic motion patterns in horses that may not be the same in both directions. These asymmetries may mask or mimic fore- or hindlimb lameness. © 2015 The Authors. Equine Veterinary Journal published by John Wiley & Sons Ltd on behalf of EVJ Ltd.

  10. Straight proximal humeral nails are surrounded by more bone stock in comparison to bent nails in an experimental cadaveric study.

    Science.gov (United States)

    Günther, Christian Max; Müller, Peter Ernst; Mutschler, Wolf; Sprecher, Christoph Martin; Milz, Stefan; Braunstein, Volker

    2014-01-01

    In the management of proximal humeral fractures intramedullary implants with bent and straight shape of the proximal part of nail are available. Based on data from previous studies on bone distribution in the humeral head, we hypothesized, that higher densities might exist in the bone stock surrounding straight nails in comparison to their angulated counterparts. With a known positive correlation between bone density and mechanical stability, this could indicate potentially higher rigidity of osteosyntheses done with straight implants. We performed high resolution peripheral quantitative computed tomographies of the potential straight and bent implant bearing regions of 27 cadaveric proximal humeri. The acquired data were analyzed for differences between straight and bent Volumes of Interest as well as intra- and interindividual bone stock distribution. For both straight and bent volumes of interest a considerably declining bone mineral density was found in craniocaudal direction. Mean densities of bent volumes were significantly lower in comparison to their corresponding straight counterparts (p straight shaped implants can be assumed. Since we found a rapid decrease of bone density in cranio-caudal direction, intramedullary implants should be anchored as proximally in the subcortical area as possible to minimize the risk of displacement or cutout. The high correlation between the Volumes of Interest of the corresponding right and left sides could aid in preoperative planning when considering an intra- or extramedullary approach.

  11. Status report on the development of a tubular electron beam ion source

    International Nuclear Information System (INIS)

    Donets, E.D.; Donets, E.E.; Becker, R.; Liljeby, L.; Rensfelt, K.-G.; Beebe, E.N.; Pikin, A.I.

    2004-01-01

    The theoretical estimations and numerical simulations of tubular electron beams in both beam and reflex mode of source operation as well as the off-axis ion extraction from a tubular electron beam ion source (TEBIS) are presented. Numerical simulations have been done with the use of the IGUN and OPERA-3D codes. Numerical simulations with IGUN code show that the effective electron current can reach more than 100 A with a beam current density of about 300-400 A/cm 2 and the electron energy in the region of several KeV with a corresponding increase of the ion output. Off-axis ion extraction from the TEBIS, being the nonaxially symmetric problem, was simulated with OPERA-3D (SCALA) code. The conceptual design and main parameters of new tubular sources which are under consideration at JINR, MSL, and BNL are based on these simulations

  12. Micro-Drilling of Polymer Tubular Ultramicroelectrode Arrays for Electrochemical Sensors

    Directory of Open Access Journals (Sweden)

    Niels B. Larsen

    2013-05-01

    Full Text Available We present a reproducible fast prototyping procedure based on micro-drilling to produce homogeneous tubular ultramicroelectrode arrays made from poly(3,4-ethylenedioxythiophene (PEDOT, a conductive polymer. Arrays of Ø 100 µm tubular electrodes each having a height of 0.37 ± 0.06 µm were reproducibly fabricated. The electrode dimensions were analyzed by SEM after deposition of silver dendrites to visualize the electroactive electrode area. The electrochemical applicability of the electrodes was demonstrated by voltammetric and amperometric detection of ferri-/ferrocyanide. Recorded signals were in agreement with results from finite element modelling of the system. The tubular PEDOT ultramicroelectrode arrays were modified by prussian blue to enable the detection of hydrogen peroxide. A linear sensor response was demonstrated for hydrogen peroxide concentrations from 0.1 mM to 1 mM.

  13. Autoimmune Hepatitis with Distal Renal Tubular Acidosis and Small Bowel Partial Malrotation.

    Science.gov (United States)

    Kanaiyalal Modi, Tejas; Parikh, Hardik; Sadalge, Abhishek; Gupte, Amit; Bhatt, Pratin; Shukla, Akash

    2015-01-01

    Renal tubular acidosis (RTA) is not uncommon in patient with chronic autoimmune hepatitis (AIH), but usually remains latent. Here, we report a case of renal tubular acidosis RTA who presented with AIH. She was also diagnosed to have partial bowel malrotation. A 9-year-old girl, a case of distal RTA, presented with jaundice, abdominal distension and altered sensorium. She was diagnosed to be AIH, which was successfully treated with steroids and azathioprine. Coexistent midgut partial malrotation with volvulus was diagnosed during the treatment. She was treated successfully with anti-tuberculous treatment for cervical lymphadenitis. Autoimmune hepatitis should not be ruled out in each case of RTA presenting with jaundice. Modi TK, Parikh H, Sadalge A, Gupte A, Bhatt P, Shukla A. Autoimmune Hepatitis with Distal Renal Tubular Acidosis and Small Bowel Partial Malrotation. Euroasian J Hepato-Gastroenterol 2015;5(2):107-109.

  14. Use and benefit summary of General Electric Company thermocase insulated tubulars for steam enhanced oil recovery

    Energy Technology Data Exchange (ETDEWEB)

    Traynor, B.V. Jr.; Hawley, J.R.; Marziani, V.J.; Prevost, W.M.

    1982-01-01

    General Electric Co.'s (GE) first well-bore insulation in 1969 resulted from the industry's need to produce hot oil on Alaska's North Slope without damaging the permafrost. In the past 3 yr, over 500,000 linear ft of GE's Thermocase has been sold. Thermocase tubulars are in use in California, Wyoming, Texas, Canada, Venezuela, and the USSR. Thermocase insulated tubulars are being used in a wide range of reservoirs under a variety of completion designs. This study discusses field experience, thermal completion benefits afforded by Thermocase tubulars, a quantified economic evaluation in a 1000-ft application, as well as GE's product verification, test and rigid quality control program.

  15. Species diversity regarding the presence of proximal tubular progenitor cells of the kidney

    Directory of Open Access Journals (Sweden)

    J. Hansson

    2016-02-01

    Full Text Available The cellular source for tubular regeneration following kidney injury is a matter of dispute, with reports suggesting a stem or progenitor cells as the regeneration source while linage tracing studies in mice seemingly favor the classical theory, where regeneration is performed by randomly surviving cells. We, and others have previously described a scattered cell population localized to the tubules of human kidney, which increases in number following injury. Here we have characterized the species distribution of these proximal tubular progenitor cells (PTPCs in kidney tissue from chimpanzee, pig, rat and mouse using a set of human PTPC markers. We detected PTPCs in chimpanzee and pig kidneys, but not in mouse tissue. Also, subjecting mice to the unilateral urethral obstruction model, caused clear signs of tubular injury, but failed to induce the PTPC phenotype in renal tubules.

  16. Interferon-γ Reduces the Proliferation of Primed Human Renal Tubular Cells

    Directory of Open Access Journals (Sweden)

    Omar García-Sánchez

    2014-01-01

    Full Text Available Background/Aims: Chronic kidney disease (CKD is a progressive deterioration of the kidney function, which may eventually lead to renal failure and the need for dialysis or kidney transplant. Whether initiated in the glomeruli or the tubuli, CKD is characterized by progressive nephron loss, for which the process of tubular deletion is of key importance. Tubular deletion results from tubular epithelial cell death and defective repair, leading to scarring of the renal parenchyma. Several cytokines and signaling pathways, including transforming growth factor-β (TGF-β and the Fas pathway, have been shown to participate in vivo in tubular cell death. However, there is some controversy about their mode of action, since a direct effect on normal tubular cells has not been demonstrated. We hypothesized that epithelial cells would require specific priming to become sensitive to TGF-β or Fas stimulation and that this priming would be brought about by specific mediators found in the pathological scenario. Methods: Herein we studied whether the combined effect of several stimuli known to take part in CKD progression, namely TGF-β, tumor necrosis factor-α, interferon-γ (IFN-γ, and Fas stimulation, on primed resistant human tubular cells caused cell death or reduced proliferation. Results: We demonstrate that these cytokines have no synergistic effect on the proliferation or viability of human kidney (HK2 cells. We also demonstrate that IFN-γ, but not the other stimuli, reduces the proliferation of cycloheximide-primed HK2 cells without affecting their viability. Conclusion: Our results point at a potentially important role of IFN-γ in defective repair, leading to nephron loss during CKD.

  17. Three-Dimensional Tubular MoS2/PANI Hybrid Electrode for High Rate Performance Supercapacitor.

    Science.gov (United States)

    Ren, Lijun; Zhang, Gaini; Yan, Zhe; Kang, Liping; Xu, Hua; Shi, Feng; Lei, Zhibin; Liu, Zong-Huai

    2015-12-30

    By using three-dimensional (3D) tubular molybdenum disulfide (MoS2) as both an active material in electrochemical reaction and a framework to provide more paths for insertion and extraction of ions, PANI nanowire arrays with a diameter of 10-20 nm can be controllably grown on both the external and internal surface of 3D tubular MoS2 by in situ oxidative polymerization of aniline monomers and 3D tubular MoS2/PANI hybrid materials with different amounts of PANI are prepared. A controllable growth of PANI nanowire arrays on the tubular MoS2 surface provides an opportunity to optimize the capacitive performance of the obtained electrodes. When the loading amount of PANI is 60%, the obtained MoS2/PANI-60 hybrid electrode not only shows a high specific capacitance of 552 F/g at a current density of 0.5 A/g, but also gives excellent rate capability of 82% from 0.5 to 30 A/g. The remarkable rate performance can be mainly attributed to the architecture with synergistic effect between 3D tubular MoS2 and PANI nanowire arrays. Moreover, the MoS2/PANI-60 based symmetric supercapacitor also exhibits the excellent rate performance and good cycling stability. The specific capacitance based on the total mass of the two electrodes is 124 F/g at a current density of 1 A/g and 79% of its initial capacitance is remained after 6000 cycles. The 3D tubular structure provides a good and favorable method for improving the capacitance retention of PANI electrode.

  18. The Test for Flow Characteristics of Tubular Fuel Assembly(II) - Experimental results and CFD analysis

    International Nuclear Information System (INIS)

    Park, Jong Hark; Chae, H. T.; Park, C.; Kim, H.

    2006-12-01

    A test facility had been established for the experiment of velocity distribution and pressure drop in a tubular fuel. A basic test had been conducted to examine the performance of the test loop and to verify the accuracy of measurement by pitot-tube. In this report, test results and CFD analysis for the hydraulic characteristics of a tubular fuel, following the previous tests, are described. Coolant velocities in all channels were measured using pitot-tube and the effect of flow rate change on the velocity distribution was also examined. The pressure drop through the tubular fuel was measured for various flow rates in range of 1 kg/s to 21 kg/s to obtain a correlation of pressure drop with variation of flow rate. In addition, a CFD(Computational Fluid Dynamics) analysis was also done to find out the hydraulic characteristics of tubular fuel such as velocity distribution and pressure drop. As the results of CFD analysis can give us a detail insight on coolant flow in the tubular fuel, the CFD method is a very useful tool to understand the flow structure and phenomena induced by fluid flow. The CFX-10, a commercial CFD code, was used in this study. The two results by the experiment and the CFD analysis were investigated and compared with each other. Overall trend of velocity distribution by CFD analysis was somewhat different from that of experiment, but it would be reasonable considering measurement uncertainties. The CFD prediction for pressure drop of a tubular fuel shows a tolerably good agreement with experiment within 8% difference

  19. Comparison of conventional straight and swan-neck straight catheters inserted by percutaneous method for continuous ambulatory peritoneal dialysis: a single-center study.

    Science.gov (United States)

    Singh, Shivendra; Prakash, Jai; Singh, R G; Dole, P K; Pant, Pragya

    2015-10-01

    To evaluate the incidence of mechanical and infectious complications of conventional straight catheter (SC) versus swan-neck straight catheter (SNSC) implanted by percutaneous method. We retrospectively analyzed 45 catheter insertions being done by percutaneous method from January 1, 2011, to May 31, 2014. SC was inserted in 24 patients, and SNSC was inserted in 21 patients. Baseline characteristics for the two groups were similar with respect to age, sex and diabetic nephropathy as the cause for end-stage renal disease. Incidence of mechanical and infectious complications in SNSC group was found to be low as compared to the SC group and was statistically significant (1 in 11.6 patient months vs. 1 in 14.4 patient months, p = 0.02). Catheter migration was found to be the most common mechanical complication (20 %), and peritonitis was found to be the most common infectious complication in conventional SC group (27 episodes in 420 patient months vs. 11 episodes in 333 patient months, p = 0.03). The incidence of exit site and tunnel infection rates revealed no difference between the groups. SNSC insertion by percutaneous method is associated with low mechanical and infectious complications.

  20. Comparison of Axillary Loop and Straight Grafts Patency and Their Complications for Hemodialylis Access

    Directory of Open Access Journals (Sweden)

    J KHoshnevis

    2011-08-01

    Full Text Available Introduction & Objective: Dialysis vascular access complications are important causes of morbidity in chronic hemodialysis patients. The aim of the present study was a comparison of auxillary loop and atraight grafts patency and its complications for hemodialysis access. Materials & Methods: In this cohort study conducted at Shahid Beheshti Medical University, 58 patients who underwent placement of loop or straight access grafts were included in the study. Demographics, primary and secondary patency rates and complications like thrombosis, infection, bleeding, steal syndrome and other complications were compared in these two groups. The collected data was analyzed by the SPSS statistical software using the chi-square test, t-test, and logistic regression. Results: Thrombosis rates were 51.1% and 53.8% in straight and loop groups respectively (P=0.862, steal syndrome rates were 2.2% and 7.7% in straight and loop groups respectively (P=0.341, psudoanevrism were 11.1% and 23.1% in straight and loop groups respectively (P=0.270, bleeding rates were 4.4% and 0% in straight and loop groups respectively (P=0.439, infection rate were 8.9% and 7.7% in straight and loop groups respectively (P=0.892, and primary patency rate after 1 month were 88.9% and 92.3% respectively (P=0.721, and primary patency rate after 24 month were 31% and 55.5% respectively (P=0.058. Secondary patency rate after 3 month were 75.6% and 92.3% respectively (P=0.189, and secondary patency rate after 24 month were 37.9% and 66.7% respectively (P=0.044. Conclusion: PTFE vascular graft seems to be an appropriate vascular access and is a promising alternative when upper extremity arteriovenous fistulas cannot be constructed. Additionally, there was no significant different between two groups for complications and early patency, but late patency was better in loop group. More study is necessary for final judgment.