WorldWideScience

Sample records for straight sections lss

  1. Excavation of LSS1

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    Excavation of the long straight-section LSS1 by an Alpine boring machine. View of the connection chamber, in the background, the roofs of the enlarged sections (8.5 m and 6 m). On the right, the access tunnel to PP1.

  2. Commissioning of the Cryogenics of the LHC Long Straight Sections

    CERN Document Server

    Perin, A; Claudet, S; Darve, C; Ferlin, G; Millet, F; Parente, C; Rabehl, R; Soubiran, M; van Weelderen, R; Wagner, U

    2010-01-01

    The LHC is made of eight circular arcs interspaced with eight Long Straight Sections (LSS). Most powering interfaces to the LHC are located in these sections where the particle beams are focused and shaped for collision, cleaning and acceleration. The LSSs are constituted of several unique cryogenic devices and systems like electrical feed-boxes, standalone superconducting magnets, superconducting links, RF cavities and final focusing superconducting magnets. This paper presents the cryogenic commissioning and the main results obtained during the first operation of the LHC Long Straight Sections.

  3. Commissioning of the cryogenics of the LHC long straight sections

    International Nuclear Information System (INIS)

    Perin, A.; Casas-Cubillos, J.; Claudet, S.; Darve, C.; Ferlin, G.; Millet, F.; Parente, C.; Rabehl, R.; Soubiran, M.; van Weelderen, R.; Wagner, U.

    2010-01-01

    The LHC is made of eight circular arcs interspaced with eight Long Straight Sections (LSS). Most powering interfaces to the LHC are located in these sections where the particle beams are focused and shaped for collision, cleaning and acceleration. The LSSs are constituted of several unique cryogenic devices and systems like electrical feed-boxes, standalone superconducting magnets, superconducting links, RF cavities and final focusing superconducting magnets. This paper presents the cryogenic commissioning and the main results obtained during the first operation of the LHC Long Straight Sections.

  4. Modifications to the SPS LSS6 Septa for LHC and the SPS Septa Diluters

    CERN Document Server

    Borburgh, Y; Goddard, B; Kadi, Y

    2006-01-01

    The Large Hadron Collider required the modification of the existing extraction channel in the long straight section (LSS) 6 of the CERN Super Proton Synchrotron (SPS), including the suppression of the electrostatic wire septa. The newly set up fast extraction will be used to transfer protons at 450 GeV/c as well as ions via the 2.9 km long transfer line TI 2 to Ring 1 of the LHC. The girder of the existing SPS DC septa was modified to accommodate a new septum protection element. Changes were also applied to the septum diluter in the fast extraction channel in LSS4, leading to the other LHC ring and the CNGS facility. The requirements and the layout of the new LSS6 extraction channel will be described including a discussion of the design and performance of the installed septum diluters.

  5. Installation and Quality Assurance of the Interconnections between Cryo-assemblies of the LHC Long Straight Sections

    CERN Document Server

    Garion, C; Tock, J P

    2006-01-01

    The interconnections between the cryomagnets and cryogenic utilities in the LHC long Straight Sections constitute the last machine installation activity. They are ensuring continuity of the beam and insulation vacuum systems, cryogenic fluid and electrical circuits and thermal insulation. The assembly is carried out in a constraining tunnel environment with restricted space. Therefore, the assembly sequence has to be well defined and specific tests have to be performed during the interconnection work to secure the reliability of the system and thus to ensure the global accelerator availability. The LHC has 8 long straight insertion zones composed of special cryomagnets involving specific interconnection procedures and QA plans. The aim of this paper is to present the installation and quality assurance procedures implemented for the LHC LSS interconnections. Technologies such as manual and automatic welding and resistive soldering will be described as well as the different quality controls, such as visual and ...

  6. Assembling the LHC short straight sections

    CERN Document Server

    Maximilien Brice

    2005-01-01

    The building where the short straight sections are being assembled, was often called ‘Lego Land’ by the workers because of the wide variety of sets of magnets and cryostats. Short straight sections contain magnets for manipulating the beam inside cryostats with liquid helium to keep the magnets at a cool 1.9 K (-271.3°C).

  7. Achievement and Evaluation of the Beam Vacuum Performance of the LHC Long Straight Sections

    CERN Document Server

    Bregliozzi, G; Blanchard, S; Hansen, J; Jiménez, J M; Weiss, K

    2008-01-01

    The bake-out and activation of the TiZrV NEG coatings of the 6 km Long Straight Sections (LSS) of the Large Hadron Collider (LHC) is in its final step. After the bakeout and the NEG activation, the average ultimate pressure, over more than one hundred vacuum sectors, is below 10^-10 Pa. Therefore, the nominal requirement for the four experimental insertions is fulfilled. The nominal performances are also ensured for all the insertions housing the collimator systems, the RF cavities and the beam dumping systems. The main difficulties encountered during the bake-out and the activation of the NEG coated chambers is presented and discussed. In particular, the acceptance test and the limiting factors of the reached ultimate pressures are addressed. Furthermore, the influence on the ultimate pressures of the beam components (collimators, beam instrumentation, etc.) is discussed. Finally, preliminary results obtained from a NEG vacuum pilot sector installed in the laboratory and dedicated to the evaluation of the NE...

  8. SPS, preassembly of short straight sections

    CERN Multimedia

    1975-01-01

    Short straight sections were preassembled with their vacuum chambers, ready for installation in the SPS. Here we see two, containing sextupoles for chromaticity adjustment. See also 7501017, 7501018, and Annual Report 1976, p.174.

  9. SPS, short straight section with sextupole

    CERN Multimedia

    CERN PhotoLab

    1975-01-01

    Short straight sections were preassembled with their vacuum chambers, ready for installation in the SPS. This one contains a sextupole for chromaticity adjustment. See also 7501017, 7501009X, and Annual Report 1974, p.174.

  10. Production of short straight sections hits 100 units

    CERN Multimedia

    2005-01-01

    The 100th short straight section for the Large Hadron Collider was assembled at CERN at the beginning of April. These units combine superconducting quadrupoles and other multipole corrector magnets, housed in their cryostats, which are used to guide, focus and fine-tune the beam in the LHC. Building 904, where the 474 short straight sections are being assembled, is often called "Lego Land" by the workers, with a touch of humor and pride because of the wide variety of these sets of magnets and cryostats .

  11. Beam line from straight-section 16

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    The start of a long trail. The beam line from straight-section 16, where protons are fast ejected, is seen at the point where it crosses the Linac shielding wall as it leaves the PS en route to the ISR.

  12. New airfoil sections for straight bladed turbine

    Science.gov (United States)

    Boumaza, B.

    1987-07-01

    A theoretical investigation of aerodynamic performance for vertical axis Darrieus wind turbine with new airfoils sections is carried out. The blade section aerodynamics characteristics are determined from turbomachines cascade model. The model is also adapted to the vertical Darrieus turbine for the performance prediction of the machine. In order to choose appropriate value of zero-lift-drag coefficient in calculation, an analytical expression is introduced as function of chord-radius ratio and Reynolds numbers. New airfoils sections are proposed and analyzed for straight-bladed turbine.

  13. New airfoil sections for straight bladed turbine

    International Nuclear Information System (INIS)

    Boumaza, B.

    1987-07-01

    A theoretical investigation of aerodynamic performance for vertical axis Darrieus wind turbine with new airfoils sections is carried out. The blade section aerodynamics characteristics are determined from turbomachines cascade model. The model is also adapted to the vertical Darrieus turbine for the performance prediction of the machine. In order to choose appropriate value of zero-lift-drag coefficient in calculation, an analytical expression is introduced as function of chord-radius ratio and Reynolds numbers. New airfoils sections are proposed and analyzed for straight-bladed turbine

  14. Commissioning of the PF Ring after the Reconstruction for the Straight-sections Upgrade

    International Nuclear Information System (INIS)

    Honda, T.; Asaoka, S.; Cheng, W. X.; Haga, K.; Harada, K.; Hori, Y.; Izawa, M.; Kasuga, T.; Kobayashi, Y.; Maezawa, H.; Mishina, A.; Mitsuhashi, T.; Miyajima, T.; Miyauchi, H.; Nagahashi, S.; Nogami, T.; Obina, T.; Pak, C. O.; Sakanaka, S.; Sasaki, H.

    2007-01-01

    At the 2.5-GeV ring of the Photon Factory, a large reconstruction of the lattice around the straight sections has been accomplished in 2005. Thus reconstruction is the main part of the straight-sections upgrade project to rebuild existing undulators and to increase the number of undulator beamlines. As a result of the reconstruction, four short straight sections have been newly created and the lengths of the existing straight sections have been much extended. To exploit the new straight sections, short-period narrow-gap undulators which have a sufficiently high brilliance in hard x-ray range have been developed. The reconstruction work of the ring was completed in a seven-month shutdown from March to September, 2005. In the area over two thirds of the storage ring, all the quadrupole magnets and all the beam ducts have been renewed and rearranged to construct the new lattice. Recommissioning of the storage ring was finished at the end of October, 2005. Though we made no in-situ baking for the beam ducts, recovery of the beam lifetime has favorably progressed due to the vacuum scrubbing by the synchrotron radiation

  15. Calculation of gas Bremsstrahlung power from straight sections of storage ring at SSRF

    International Nuclear Information System (INIS)

    Hua Zhengdong; Xu Xunjiang; Fang Keming; Xu Jiaqiang

    2008-01-01

    The Shanghai Synchrotron Radiation Facility (SSRF) is a third-generation synchrotron radiation light source with 3.5 GeV in energy, which is composed of the linear accelerator, the booster and the storage ring. The storage ring provides 16 standard straight sections of 6.5 m and 4 long straight sections of 12 meters. Gas Bremsstrahlung (GB) produced by the interaction of the stored beam with the residual gas molecules in straight section, which is so intense and has a very small angular that the GB spectra, the GB power and the GB power distribution should be known. The characters of GB are studied by means of Fluka Monte Carlo code. Our result shows agreement with those obtained by the experiential formulae. (authors)

  16. Status of PF-ring commissioning after the reconstruction for the straight-sections upgrade

    International Nuclear Information System (INIS)

    Tanimoto, Yasunori; Miyauchi, Hiroshi; Honda, Tohru; Kobayashi, Yukinori

    2006-01-01

    The upgrade project of the straight sections at the PF-ring enables the reinforcement of insertion devices and their beamlines. As a main part of this project, a large-scale reconstruction of the storage ring was carried out from March to September in 2005. The lattice configuration was modified to create short straight sections of 1.4 m and to extend the existing straight sections. Optical functions of the short sections were optimized for short-gap mini-pole undulators as X-ray sources. The first mini-pole undulator SGU no.17 has been operated for a protein crystallography. A recommissioning of the ring was conducted for about one month, and user experiments were restarted on 18th October 2005 according to schedule. The recovery of the beam lifetime due to the process of the vacuum scrubbing has been favorably progressed. (author)

  17. Manufacture of the straight section chambers for the SPring-8 storage ring

    International Nuclear Information System (INIS)

    Watanabe, K.; Saeki, H.; Sakaue, H.; Ohkuma, H.; Be, S.H.; Oishi, M.; Tuchiya, M.; Nishidono, T.

    1995-01-01

    To carry out the performance test of the vacuum system, we manufactured three different straight section chambers prior to the manufacture of the 48 cell full scale vacuum systems. One of three straight section chambers contains only downstream end absorber, while the other two contain a downstream end absorber, upstream end bellows and a photon beam extraction duct. In this paper, the manufacture of these chambers and their assemblies are described in detail. (author). 1 ref., 3 figs., 3 tabs

  18. SPS slow extraction septa

    CERN Multimedia

    CERN PhotoLab

    1979-01-01

    SPS long straight section (LSS) with a series of 5 septum tanks for slow extraction (view in the direction of the proton beam). There are 2 of these: in LSS2, towards the N-Area; in LSS6 towards the W-Area. See also Annual Report 1975, p.175.

  19. A preliminary report on OCR problems in LSS document conversion

    International Nuclear Information System (INIS)

    Nartker, T.A.; Kanal, J.; Rice, S.V.

    1992-01-01

    In this paper, the authors present the results of a study to identify the predominant problems which contemporary OCR devices have in converting LSS document images into computer readable text. The results indicate that the majority of residual OCR errors are caused by either broken or touching characters. The relationship between the cost of constructing the LSS system and the number of OCR errors made during LSS data capture is analyzed. if 100% of the conversion problems caused by broken characters alone could be eliminated, the potential LSS cost savings is approximately $31,000,000

  20. NEG coating of the non-standard LSS vacuum chambers

    CERN Document Server

    Costa-Pinto, P

    2005-01-01

    The vacuum chambers of nearly all the warm magnets of the LHC (MBXW, MQW, MSI, MSD, etc…) will be coated with a Ti-Zr-V thin film by magnetron sputtering. The NEG coating is necessary to provide uniform pumping speed along the chambers and to suppress electron cloud instabilities and dynamic outgassing. The about 300 chambers will be coated using the existing facility, developed for the production of the standard LSS chambers, after minor modifications mainly due to the different cross sections. In order to cope with the present installation schedule, the production planning will allow processing of different families of chambers in parallel by using two or three coating systems simultaneously. After a brief introduction to the Ti-Zr-V characteristics and performances, the coating facility and strategy will be illustrated as well as the possible conflicts due to uncertainties in the planning of the experimental beam pipes and the standard LSS chambers.

  1. Alignment and girder position of MSE septa in the new LSS4 extraction channel of the SPS

    CERN Document Server

    Balhan, B; Rizzo, A; Weterings, W; CERN. Geneva. SPS and LHC Division

    2002-01-01

    For the extraction of the beam from the Super Proton Synchrotron (SPS) to ring 2 of the Large Hadron Collider (LHC) and the CERN Neutrino to Gran Sasso (CNGS)facility, a new fast-extraction system is being constructed in the long straight section LSS4 of the SPS. Besides extraction bumpers, enlarged aperture quadrupoles and extraction kicker magnets (MKE), six conventional DC septum magnets (MSE) are used. These magnets are mounted on a single rigid support girder, pre-aligned so as to follow the trajectory of the extracted beam and optimise the available aperture. The girder has been motorised in order to optimise the local SPS aperture during setting up, so as to avoid the risk of circulating beam impact on the septum coils. In this note, we briefly present the trajectory and apertures of the beam, we describe the calculations and methods that have been used to determine the magnet position on the girder, and finally we report on the details of the girder movement and alignment.

  2. The short straight sections for the LHC

    International Nuclear Information System (INIS)

    Bergot, J.B.; Coussy, E.; Dambre, P.; Ollivier, Y.; Reynet, D.; Vincent, D.; Rohmig, P.

    1999-01-01

    In 1995 a close collaboration between CERN, CEA and CNRS has been established for the design, proto-typing and follow-up of industrial series production of a sub-assembly of the Large Hadron Collider (LHC). In this frame, the design office of IPN's Accelerator R and D group has in charge one of these contracts concerning the 386 Short Straight Sections (SSS) and particularly: - the cryostat design; - the study of procedures and tool assembly; - the construction of two prototypes during the year 1999; - the industrialization and the production follow-up for the series SSS. This collaboration will last until the year 2004. (authors)

  3. Bed shear stress distribution in straight channels with arbitrary cross section

    DEFF Research Database (Denmark)

    Christensen, Henrik Bo; Fredsøe, Jørgen

    1998-01-01

    The bed shear stress distribution in straight open channels is affected by mechanisms as bed curvature of the cross section profile, shear diffusion, and secondary currents. This paper compares some analytical and numerical methods to estimate the bed shear stress distribution. The methods...

  4. Design and installation of the MSE septum system in the new LSS4 extraction channel of the SPS

    CERN Document Server

    Balhan, B; Guinand, R; Luiz, F; Rizzo, A; Weterings, W; CERN. Geneva. AB Department

    2003-01-01

    For the extraction of the beam from the Super Proton Synchrotron (SPS) to ring 2 of the Large Hadron Collider (LHC) and the CERN Neutrino to Gran Sasso (CNGS) facility, a new fast-extraction system has been installed in the long straight section LSS4 of the SPS. Besides extraction bumpers, enlarged aperture quadrupoles and extraction kicker magnets (MKE), six conventional DC septum magnets (MSE) are used. These magnets are mounted on a single mobile retractable support girder, which is motorised in order to optimise the local SPS aperture during setting up. The MSE septa are connected by a so-called plug-in system to a rigid water-cooled bus bar, which itself is powered by water-cooled cables. In order to avoid destruction of the septum magnet coils by direct impact of the extracted beam, a dilution element (TPSG) has been placed immediately upstream of the first septum coil. The whole system is kept at the required vacuum pressure by ion pumps attached to separate modules (MP). In this note we present the de...

  5. Ring energy selection and extra long straight sections for the Advanced Photon Source

    International Nuclear Information System (INIS)

    1987-04-01

    Recommended criteria are given for the performance of Advanced Photon Source (APS), taking into consideration undulator tunability criteria and their relationship to the storage ring energy and undulator gap, length of straight sections

  6. The DFBX cryogenic distribution boxes for the LHC straight sections

    International Nuclear Information System (INIS)

    Zbasnik, Jon P.; Corradi, Carol A.; Green, Michael A.; Kajiyama, Y.; Knolls, Michael J.; LaMantia, Roberto F.; Rasson, Joseph E.; Reavill, Dulie; Turner, William C.

    2002-01-01

    The DFBX distribution boxes are designed to connect the LHC cryogenic distribution system to the interaction region quadrupoles [1] and dipoles for the Large Hadron Collider (LHC). The DFBX distribution boxes also have the current leads for the superconducting interaction region magnets and the LHC interaction region correction coils. The DFBX boxes also connect the magnet and cryogenic instrumentation to the CERN data collection system. The DFBX boxes serve as the cryogenic circulation center and the nerve center for four of the LHC straight sections. This report describes primarily the cryogenic function of the DFBXs

  7. Needlet estimation of cross-correlation between CMB lensing maps and LSS

    Energy Technology Data Exchange (ETDEWEB)

    Bianchini, Federico [Astrophysics Sector, SISSA, Via Bonomea 265, I-34136 Trieste (Italy); Renzi, Alessandro; Marinucci, Domenico, E-mail: fbianchini@sissa.it, E-mail: renzi@mat.uniroma2.it, E-mail: marinucc@mat.uniroma2.it [Dipartimento di Matematica, Università di Roma Tor Vergata, Via della Ricerca Scientifica 1, 00133 Roma (Italy)

    2016-11-01

    In this paper we develop a novel needlet-based estimator to investigate the cross-correlation between cosmic microwave background (CMB) lensing maps and large-scale structure (LSS) data. We compare this estimator with its harmonic counterpart and, in particular, we analyze the bias effects of different forms of masking. In order to address this bias, we also implement a MASTER-like technique in the needlet case. The resulting estimator turns out to have an extremely good signal-to-noise performance. Our analysis aims at expanding and optimizing the operating domains in CMB-LSS cross-correlation studies, similarly to CMB needlet data analysis. It is motivated especially by next generation experiments (such as Euclid) which will allow us to derive much tighter constraints on cosmological and astrophysical parameters through cross-correlation measurements between CMB and LSS.

  8. The Teams from Building 904 celebrated the assembly of the 100th short straight section on 11 April

    CERN Multimedia

    Patrice Loiez

    2005-01-01

    The 100th short straight section for the Large Hadron Collider was assembled at CERN at the beginning of April. These units combine superconducting quadrupoles and other multipole corrector magnets, housed in their cryostats, which are used to guide, focus and fine-tune the beam in the LHC. Building 904, where the 474 short straight sections are being assembled, is often called "Lego Land" by the workers, with a touch of humor and pride because of the wide variety of these sets of magnets and cryostats

  9. Efficient exploration of cosmology dependence in the EFT of LSS

    Energy Technology Data Exchange (ETDEWEB)

    Cataneo, Matteo [Dark Cosmology Centre, Niels Bohr Institute, University of Copenhagen, Juliane Maries Vej 30, 2100 Copenhagen (Denmark); Foreman, Simon; Senatore, Leonardo, E-mail: matteoc@dark-cosmology.dk, E-mail: sfore@stanford.edu, E-mail: senatore@stanford.edu [Stanford Institute for Theoretical Physics and Department of Physics, Stanford University, 382 Via Pueblo Mall, Stanford, CA 94306 (United States)

    2017-04-01

    The most effective use of data from current and upcoming large scale structure (LSS) and CMB observations requires the ability to predict the clustering of LSS with very high precision. The Effective Field Theory of Large Scale Structure (EFTofLSS) provides an instrument for performing analytical computations of LSS observables with the required precision in the mildly nonlinear regime. In this paper, we develop efficient implementations of these computations that allow for an exploration of their dependence on cosmological parameters. They are based on two ideas. First, once an observable has been computed with high precision for a reference cosmology, for a new cosmology the same can be easily obtained with comparable precision just by adding the difference in that observable, evaluated with much less precision. Second, most cosmologies of interest are sufficiently close to the Planck best-fit cosmology that observables can be obtained from a Taylor expansion around the reference cosmology. These ideas are implemented for the matter power spectrum at two loops and are released as public codes. When applied to cosmologies that are within 3σ of the Planck best-fit model, the first method evaluates the power spectrum in a few minutes on a laptop, with results that have 1% or better precision, while with the Taylor expansion the same quantity is instantly generated with similar precision. The ideas and codes we present may easily be extended for other applications or higher-precision results.

  10. gamboostLSS: An R Package for Model Building and Variable Selection in the GAMLSS Framework

    Directory of Open Access Journals (Sweden)

    Benjamin Hofner

    2016-10-01

    Full Text Available Generalized additive models for location, scale and shape are a flexible class of regression models that allow to model multiple parameters of a distribution function, such as the mean and the standard deviation, simultaneously. With the R package gamboostLSS, we provide a boosting method to fit these models. Variable selection and model choice are naturally available within this regularized regression framework. To introduce and illustrate the R package gamboostLSS and its infrastructure, we use a data set on stunted growth in India. In addition to the specification and application of the model itself, we present a variety of convenience functions, including methods for tuning parameter selection, prediction and visualization of results. The package gamboostLSS is available from the Comprehensive R Archive Network (CRAN at https://CRAN.R-project.org/package=gamboostLSS.

  11. Modelling of flexibles for structural analysis of short straight section of Large Hadron Collider

    International Nuclear Information System (INIS)

    Abhay Kumar; Dutta, Subhajit; Dwivedi, Jishnu; Soni, H.C.

    2003-01-01

    Short Straight Section (SSS) of Large hadron Collider (LRCM) is a 8-meter long structure with a diameter of 1 meter and it houses a twin quadrupole. The cryogens are fed to the Sass through a jumper connection between Cryogenic Distribution Line (QRL) and SSS. The bus bars travel through interconnection bellows to adjoining magnets. CAT is studying the structural behavior of cold mass and the cryostat when subjected to various forces imposed on the SSS under various operating conditions of LHC machine including realignment required to compensate local sinking of the floor of the tunnel during the LHC machine's lifetime. CAT did calculation of reaction forces and moments on the Short Straight Section due to presence of jumper connection last year after the experimental verification of finite element model at CERN. Subsequently, a unified Fe model consisting of cold mass, cold feet, vacuum vessel, main vacuum vessel bellows (large sleeves), magnet interconnects, jumper connection, service module and precision motion jacks is being developed for studying the structural behaviour. (author)

  12. Novel Concept for LSS Based on Advanced Microalgal Biotechnologies

    Science.gov (United States)

    Brown, I.; Jones, J. A.; Bayless, D.; Karakis, S.; Karpov, L.; McKay, D. S.

    2006-01-01

    One of the key issues for successful human space exploration is biomedical life support in hostile space and planetary environments that otherwise cannot sustain life. Bioregenerative life support systems (LSS) are one of the options for atmospheric regeneration. To date, no bioregenerative LSS has shown capability for 100% air regeneration. Nor have these LSS been robust enough to simultaneously provide a regenerable complete food source. In contrast to microalgae, traditional plant approaches, e.g. wheat and lettuce, are lacking essential amino acids, vitamins, and micronutrients. Moreover, the rate of photosynthesis by microalgae significantly exceeds that of high plants. Nevertheless, the employment of microalgae in LSS technology was restricted, until recently, due to high water demands. Also the per person requirement of a 40L volume of microalgae in a photobioreactor, to provide daily O2 production, made an algae-based approach less attractive. By employing a vertically stacked membrane bioreactor, coupled with a solar tracker and photon-delivery system, a lightweight air revitalization system for space based applications, with minimal water requirements, can be developed. Our preliminary estimations suggest that a membrane bioreactor, 8m3 in volume, comprised of 80m2 (twenty 2m x 2m membranes, each spaced 10 cm apart), and a total of 70L of water could produce 2.7 kg of dried microalgal biomass that would supply the energy and essential amino acid requirements, as well as producing sufficient O2 for the daily needs of a 15 member crew. Research on the biochemical content of edible blue-green alga Spirulina (Arthrospira) platensis shows a wide spectrum of stable Spirulina mutants with an enhanced content of amino acids, -carotene, and phycobilliprotein c-phycocyanin. Feeding animals suffering from radiation-induced lesions, c-phycocyanin, extracted from strain 27G, led to a correction in the decrement of dehydrogenase activity and energy-rich phosphate

  13. Broadband Silicon-On-Insulator directional couplers using a combination of straight and curved waveguide sections.

    Science.gov (United States)

    Chen, George F R; Ong, Jun Rong; Ang, Thomas Y L; Lim, Soon Thor; Png, Ching Eng; Tan, Dawn T H

    2017-08-03

    Broadband Silicon-On-Insulator (SOI) directional couplers are designed based on a combination of curved and straight coupled waveguide sections. A design methodology based on the transfer matrix method (TMM) is used to determine the required coupler section lengths, radii, and waveguide cross-sections. A 50/50 power splitter with a measured bandwidth of 88 nm is designed and fabricated, with a device footprint of 20 μm × 3 μm. In addition, a balanced Mach-Zehnder interferometer is fabricated showing an extinction ratio of >16 dB over 100 nm of bandwidth.

  14. UHV testing of spare straight section chambers of Indus-2

    International Nuclear Information System (INIS)

    Tiwari, S.K.; Ratnakala, K.C.; Sridhar, R.; Bhange, N.J.; Netram; Shukla, S.K.

    2015-01-01

    The vacuum system of Synchrotron Radiation Source, Indus-2, in RRCAT has been functioning up to the mark, continuously for last 10 years. To continue the same trouble-free functioning, it was planned to procure spares for all critical vacuum components, test for UHV performance and keep ready for installation, in case of requirement. As a part of this planning, fifteen chambers made of Aluminium alloy (6063 T6), procured as spare straight section chambers for Indus-2, and were tested for UHV performance. They were tested in batches of 2 or 3 chambers, depending upon their length, and the similar testing-procedure was followed. This paper narrates the tests carried out, and the results obtained. Ultimate vacuum in the range (2 to 9) x 10 -10 mbar was achieved. (author)

  15. 7 CFR 29.6128 - Straight Stripped (X Group).

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Straight Stripped (X Group). 29.6128 Section 29.6128... REGULATIONS TOBACCO INSPECTION Standards Grades § 29.6128 Straight Stripped (X Group). This group consists of..., and tolerances X1 Fine Quality Straight Stripped. Heavy, ripe, firm, semielastic, normal strength and...

  16. The vacuum system for the PEP II high energy ring straight sections

    International Nuclear Information System (INIS)

    Wienands, U.; Daly, E.; Heifets, S.A.; Kulikov, A.; Kurita, N.; Nordby, M.; Perkins, C.; Reuter, E.; Seeman, J.T.; Belser, F.C.; Berg, J.; Holdener, F.R.; Kerns, J.A.; McDaniel, M.R.; Stoeffl, W.

    1995-01-01

    The six straight sections of the PEP II High Energy Ring (HER) serve various functions: lattice tuning, beam injection and abort, providing space for rf cavities, longitudinal and transverse feedback, beam diagnostics and the interaction point. A stainless steel vacuum system has been designed; prototypes are currently being built. Cooling is required due to radiation coming from the last arc dipole and resistive losses in the vacuum chamber. Although the nominal beam current of the HER is 1 A the vacuum system is designed for 3 A to provide margin and an upgrade path. 5 refs., 7 figs

  17. Thermal Performance of the LHC Short Straight Section Cryostat

    CERN Document Server

    Bergot, J B; Nielsen, L; Parma, Vittorio; Rohmig, P; Roy, E

    2002-01-01

    The LHC Short Straight Section (SSS) cryostat houses and thermally protects in vacuum the cold mass which contains a twin-aperture superconducting quadrupole magnet and superconducting corrector magnets operating at 1.9 K in superfluid helium. In addition to mechanical requirements, the cryostat is designed to minimize the heat in-leak from the ambient temperature to the cold mass. Mechanical components linking the cold mass to the vacuum vessel such as support posts and an insulation vacuum barrier are designed to have minimum heat conductivity with efficient thermalisations for heat interception. Heat in-leak by radiation is reduced by employing multilayer insulation wrapped around the cold mass and an actively cooled aluminium thermal shield. The recent commissioning and operation of two SSS prototypes in the LHC Test String 2 have given a first experimental validation of the thermal performance of the SSS cryostat in nominal operating conditions. Temperature sensors mounted in critical locations provide a...

  18. 26 CFR 1.167(b)-1 - Straight line method.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Straight line method. 1.167(b)-1 Section 1.167(b... Straight line method. (a) In general. Under the straight line method the cost or other basis of the... may be reduced to a percentage or fraction. The straight line method may be used in determining a...

  19. 14 CFR 417.215 - Straight-up time analysis.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Straight-up time analysis. 417.215 Section..., DEPARTMENT OF TRANSPORTATION LICENSING LAUNCH SAFETY Flight Safety Analysis § 417.215 Straight-up time analysis. A flight safety analysis must establish the straight-up time for a launch for use as a flight...

  20. Very fine pumps

    CERN Multimedia

    2004-01-01

    In Building 181, half the total number of vacuum chambers required for the LHC Long Straight Sections (LSS) have now been coated with getter material by sputtering. This innovative technique, invented at CERN, will be used on all the LHC 's "warm" vacuum chambers.

  1. Electronic stopping power of polymers for heavy ions in the ion energy domain of LSS theory

    International Nuclear Information System (INIS)

    Neetu; Pratibha; Sharma, V.; Diwan, P.K.; Kumar, Shyam

    2009-01-01

    LSS based computed electronic stopping power values have been compared with the corresponding measured values in polymers for heavy ions with Z = 5-29, in the reduced ion velocity region, v red ≤ 1. Except for limited v red ∼ 0.6-0.85, the formulation generally shows significantly large deviations with the measured values. The ζ factor, which was approximated to be ∼Z 1 1/6 , involved in LSS theory has been suitably modified in the light of the available experimental stopping power data. The calculated stopping power values after incorporating modified ζ in LSS formula have been found to be in close agreement with measured values in various polymers in the reduced ion velocity range 0.35 ≤ v red ≤ 1.0.

  2. gamboostLSS: An R Package for Model Building and Variable Selection in the GAMLSS Framework

    OpenAIRE

    Hofner, Benjamin; Mayr, Andreas; Schmid, Matthias

    2014-01-01

    Generalized additive models for location, scale and shape are a flexible class of regression models that allow to model multiple parameters of a distribution function, such as the mean and the standard deviation, simultaneously. With the R package gamboostLSS, we provide a boosting method to fit these models. Variable selection and model choice are naturally available within this regularized regression framework. To introduce and illustrate the R package gamboostLSS and its infrastructure, we...

  3. Electronic stopping power of polymers for heavy ions in the ion energy domain of LSS theory

    Energy Technology Data Exchange (ETDEWEB)

    Neetu [Department of Physics, Kurukshetra University, Kurukshetra 136 119, Haryana (India)], E-mail: neetuphy@gmail.com; Pratibha [Department of Physics, Kurukshetra University, Kurukshetra 136 119, Haryana (India); Sharma, V. [Department of Physics, Lovely Professional University, Phagwara 144 402 (India); Diwan, P.K. [Department of Physics, U.I.E.T., Kurukshetra University, Kurukshetra 136119, Haryana (India); Kumar, Shyam [Department of Physics, Kurukshetra University, Kurukshetra 136 119, Haryana (India)

    2009-04-15

    LSS based computed electronic stopping power values have been compared with the corresponding measured values in polymers for heavy ions with Z = 5-29, in the reduced ion velocity region, v{sub red} {<=} 1. Except for limited v{sub red} {approx} 0.6-0.85, the formulation generally shows significantly large deviations with the measured values. The {zeta} factor, which was approximated to be {approx}Z{sub 1}{sup 1/6}, involved in LSS theory has been suitably modified in the light of the available experimental stopping power data. The calculated stopping power values after incorporating modified {zeta} in LSS formula have been found to be in close agreement with measured values in various polymers in the reduced ion velocity range 0.35 {<=} v{sub red} {<=} 1.0.

  4. Proposal to Negotiate an Amendment to an Existing Contract and Several Contracts for the Supply and Assembly of the LHC Short Straight Section Cryostats

    CERN Document Server

    2002-01-01

    Following the insolvency of a major contractor, CERN proposes to negotiate an amendment to an existing contract and to place several contracts for the supply of 360 LHC arc short straight section cryostats and their assembly, eight spare cryostat units and components for 64 LHC dispersion suppressor short straight section cryostats. The Finance Committee is therefore invited to approve an amendment to an existing contract with the consortium: &8721; INTERTEC (DK) - CEGELEC (FR) - SPIE TRINDEL (FR) to include assembly of the LHC arc short straight sections, for an additional amount of 4 088 470 euros (6 205 480 Swiss francs), subject to revision for inflation after 31 December 2002; the consortium has indicated the following distribution by country of the contract value covered by this adjudication proposal : DK - 52%, FR - 48%; and to the negotiation of contracts for the supply of related major components with the firms: &8721; SES (SK) for the supply of vacuum vessels for an amount of 5 538 533 euros...

  5. Structural damping results from vibration tests of straight piping sections

    International Nuclear Information System (INIS)

    Ware, A.G.; Thinnes, G.L.

    1984-01-01

    EG and G Idaho is assisting the USNRC and the Pressure Vessel Research Committee in supporting a final position on revised damping values for structural analyses of nuclear piping systems. As part of this program, a series of vibrational tests on 76-mm and 203-mm (3-in. amd 8-in.) Schedule 40 carbon steel piping was conducted to determine the changes in structural damping due to various parametric effects. The 10-m (33-ft) straight sections of piping were rigidly supported at the ends. Spring, rod, and constant force hangers, as well as a sway brace and snubbers were included as intermediate supports. Excitation was provided by low-force level hammer inpacts, a hydraulic shaker, and a 445-kN (50-ton) overhead crane. Data was recorded using acceleration, strain, and displacement time histories. This paper presents results from the testing showing the effect of stress level and type of supports on structural damping in piping

  6. Electrical and Magnetic Performance of the LHC Short Straight Sections

    CERN Document Server

    Sanfilippo, S; Bottura, L; Buzio, M; Coccoli, M; García-Pérez, J; Pugnat, P; Sammut, N; Siemko, A; Smirnov, N; Stafiniak, A; Wildner, E

    2006-01-01

    The Short Straight Section (SSS) for the Large Hadron Collider arcs, containing in a common cryostat the lattice quadrupoles and correction magnets, have now entered series production. The foremost features of the lattice quadrupole magnets are a two-in-one structure containing two 56 mm aperture, two-layers coils wound from 15.1 mm wide NbTi cables, enclosed by the stainless steel collars and ferromagnetic yoke, and inserted into the inertia tube. Systematic cryogenic tests are performed at CERN in order to qualify these magnets with respect to their cryogenic and electrical integrity, the quench performance and the field quality in all operating conditions. This paper reports the main results obtained during tests and measurements in superfluid helium. The electrical characteristics, the insulation measurements and the quench performance are compared to the specifications and expected performances for these magnets. The field in the main quadrupole is measured using three independent systems: 10-m lon...

  7. La binaria LSS 3074 y su entorno: ?`una nueva asociación OB?

    Science.gov (United States)

    Niemela, V.; Morrell, N.; Corti, M.

    En este trabajo presentamos un nuevo análisis orbital de LSS~3074, junto con tipos espectrales y velocidades radiales de estrellas que podrían constituir con ella una nueva asociación OB. La estrella O4f LSS3074 fue descubierta como binaria espectroscópica de corto período y líneas dobles por Morrell & Niemela (1990, ASP Conf. Ser. 7, 57). Posteriormente, Haefner et~al.(1994, IBVS 3969) encontraron variaciones fotométricas, estimando una inclinación orbital entre 50o y 55o. Teniendo en cuenta la importancia de obtener valores empíricos para las masas de estrellas O tempranas, y considerando la gran dispersión existente entre los valores observados y su discrepancia con los predichos por los modelos teóricos, hemos obtenido nuevas observaciones espectroscópicas de este sistema, con el propósito de mejorar los elementos orbitales derivados en la solución preliminar. Además, como las estrellas O tempranas suelen formar parte de cúmulos y asociaciones OB, hemos llevado a cabo una investigación espectroscópica de varias estrellas tempranas que podrían estar físicamente relacionadas con LSS~3074.

  8. On the determination of neutrino masses and dark energy evolution from the cross-correlation of CMB and LSS

    International Nuclear Information System (INIS)

    Ichikawa, Kazuhide; Takahashi, Tomo

    2008-01-01

    We discuss the possibilities of the simultaneous determination of the neutrino masses and the evolution of dark energy from future cosmological observations such as cosmic microwave background (CMB), large scale structure (LSS) and the cross-correlation between them. Recently it has been discussed that there is a degeneracy between the neutrino masses and the equation of state for dark energy. It is also known that there are some degeneracies among the parameters describing the dark energy evolution. We discuss the implications of these for the cross-correlation of CMB with LSS in some detail. Then we consider to what extent we can determine the neutrino masses and the dark energy evolution using the expected data from CMB, LSS and their cross-correlation

  9. Curved-straight neutron guide system with uniform spatial intensity distribution

    International Nuclear Information System (INIS)

    Mildner, D.F.R.; Cook, J.C.

    2008-01-01

    The spatial intensity distribution of neutrons emerging from a curved guide is asymmetric, and straight guide sections are sometimes appended to curved guides to make the intensity distribution more nearly uniform. For idealized uniform illumination and in the perfect reflectivity approximation, the spatial-angular acceptance at the exit of the combination can be made exactly uniform for a range of long wavelengths by using a sufficiently long straight section, together with a curved guide whose outer wall coating has a critical angle slightly greater than those of the other guide walls. We refer to this as a 'phase space tailoring guide' where the coatings on the inner wall and straight section are used to define the required divergence at the end of the guide. Increasing the critical angle of the outer wall of the curved section reduces the characteristic wavelength of the curved guide as well as the wavelength at which ideal uniformity can be obtained. The outer wall coating need only be of sufficiently high critical angle to fill the transmittable phase space area of the straight guide uniformly to adequately short wavelength

  10. Non-local Fast Extraction from the CERN SPS at 100 and 440 GeV

    CERN Document Server

    Velotti, F M; Bartmann, W; Carlier, E; Cornelis, K; Efthymiopoulos, I; Goddard, B; Jensen, L K; Kain, V; Kowalska, M; Mertens, V; Steerenberg, R

    2013-01-01

    The Long Straight Section 2 (LSS2) of the CERN SPS is connected with the North Area (NA), to which the beam to date has always been extracted using a resonant extraction technique. For new proposed short- and long-baseline neutrino experiments, a fast single turn extraction to this experimental area is required. As there are no kickers in LSS2, and the integration of any new kickers with the existing electrostatic septum would be problematic, a solution has been developed to fast extract the beam using non-local extraction with other SPS kickers. Two different kicker systems have been used, the injection kicker in LSS1 and the stronger extraction kicker in LSS6 to extract 100 and 440 GeV beam, respectively. For both solutions a large emittance beam was extracted after 5 or 9 full betatron periods. The concept and simulation details are presented with the analysis of the aperture and beam loss considerations and experimental results collected during a series of beam tests.

  11. Proposal to negotiate an amendment to an existing contract for the supply of additional vacuum vessels for the short-straight sections of the LHC

    CERN Document Server

    2005-01-01

    This document concerns the proposal to negotiate an amendment to an existing contract for the supply of additional vacuum vessels for the short-straight sections of the LHC. For the reasons explained in this document, the Finance Committee is invited to approve an amendment to an existing contract with SLOVENSKE ENERGETICKE STROJARNE (SK) for the supply of 25 additional vacuum vessels for the short-straight sections for the LHC for an amount of 140 000 euros (216 999 Swiss francs), subject to revision for inflation, bringing the total to a maximum amount of 6 176 855 euros (9 574 097 Swiss francs), subject to revision for inflation. The rate of exchange used is that stipulated in the tender.

  12. Biosphere of the earth as a life-support system (LSS) for mankind

    Science.gov (United States)

    Pechurkin, Nickolay

    As a component of biosphere the mankind became the most powerful and active link recently. Exponential growth of human population number and of some technological indicators of its development becomes menacing for steady (stationary or close-to-stationary) functioning of biosphere as single whole. Anyway, we should be able to estimate quantitatively limits of pos-sible anthropogenic impact on functional parameters of biosphere. Considering biosphere as a natural LSS, we can receive the helpful information for working out and creation of artificial LSS of various types. Big biotic cycle induced with flows of a solar energy, is a basis of func-tioning of biosphere and its basic cells -ecosystems. In comparison with the majority natural ecosystems, the biosphere has very high factor of closure of substance circulation, especially limiting biogenic elements: nitrogen and phosphorus. Voluntarily or not, the mankind interferes in big biotic cycle and modifies it. For example, extracting mineral fertilizers for cultivation of agricultural crops, we return in circulation lost before substances, type nitric, potassic, phos-phoric salts. Burning fossils of organic carbon (oil, gas, coal), we raise concentration of carbon dioxide in atmosphere. The melting of a permafrost connected with activity of mankind, is capable to lead to excretion of other greenhouse gases, in particular, methane. It's possible to summarize briefly the main functional properties of the biosphere: Integrity, Closure, Substance cycling, Steady state, Energy dependence. These properties of the biosphere, as a LSS, ensure potentially everlasting life under the conditions of a limited quantity of substrate suitable for the life on the planet. But the selfish mankind is able to destroy harmonic adjustment of this unique natural mechanism

  13. Fast-Solving Quasi-Optimal LS-S3VM Based on an Extended Candidate Set.

    Science.gov (United States)

    Ma, Yuefeng; Liang, Xun; Kwok, James T; Li, Jianping; Zhou, Xiaoping; Zhang, Haiyan

    2018-04-01

    The semisupervised least squares support vector machine (LS-S 3 VM) is an important enhancement of least squares support vector machines in semisupervised learning. Given that most data collected from the real world are without labels, semisupervised approaches are more applicable than standard supervised approaches. Although a few training methods for LS-S 3 VM exist, the problem of deriving the optimal decision hyperplane efficiently and effectually has not been solved. In this paper, a fully weighted model of LS-S 3 VM is proposed, and a simple integer programming (IP) model is introduced through an equivalent transformation to solve the model. Based on the distances between the unlabeled data and the decision hyperplane, a new indicator is designed to represent the possibility that the label of an unlabeled datum should be reversed in each iteration during training. Using the indicator, we construct an extended candidate set consisting of the indices of unlabeled data with high possibilities, which integrates more information from unlabeled data. Our algorithm is degenerated into a special scenario of the previous algorithm when the extended candidate set is reduced into a set with only one element. Two strategies are utilized to determine the descent directions based on the extended candidate set. Furthermore, we developed a novel method for locating a good starting point based on the properties of the equivalent IP model. Combined with the extended candidate set and the carefully computed starting point, a fast algorithm to solve LS-S 3 VM quasi-optimally is proposed. The choice of quasi-optimal solutions results in low computational cost and avoidance of overfitting. Experiments show that our algorithm equipped with the two designed strategies is more effective than other algorithms in at least one of the following three aspects: 1) computational complexity; 2) generalization ability; and 3) flexibility. However, our algorithm and other algorithms have

  14. Summary of Recent Studies of Cryosorbers for LHC Long Straight Sections

    CERN Document Server

    Dostovalov, Rodion; Krasnov, Alexandre

    2005-01-01

    The vacuum chamber inside some cryogenic elements in the LHC long straight sections will have cold bore (CB) at 4.5K and a beam screen (BS) at temperature between 5 and 20K. The gas molecules desorbed due to photons and electrons will pass through the slots on the BS to the shadowed part between the CB and BS. All desorbed gases except H2 could be adsorbed on the CB and BS but a cryosorber is required to pump H2. The new types of anodized aluminum, porous copper and charcoal-based materials were developed and studied to cryopump H2 at temperatures between 10 and 20K. The advantages and disadvantages of cryosorbers and technological problems of development of new similar cryosorbers were defined. The vacuum parameters of LHC vacuum chamber prototypes with charcoal and two types of carbon fiber cryosorbers were measured. The dynamic pressure behavior at BS temperature oscillations was studied for BS with woven carbon fiber to predict the dynamic pressure at nonstandard or transient regimes of the LHC operation....

  15. 26 CFR 1.9001 - Statutory provisions; Retirement-Straight Line Adjustment Act of 1958.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 13 2010-04-01 2010-04-01 false Statutory provisions; Retirement-Straight Line... provisions; Retirement-Straight Line Adjustment Act of 1958. Section 94 of the Technical Amendments Act of 1958 (72 Stat. 1669) provides as follows: Sec. 94. Change from retirement to straight line method of...

  16. 21 CFR 70.20 - Packaging requirements for straight colors (other than hair dyes).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Packaging requirements for straight colors (other than hair dyes). 70.20 Section 70.20 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH... straight colors (other than hair dyes). Straight colors shall be packaged in containers which prevent...

  17. LSS-GAC - A LAMOST Spectroscopic Survey of the Galactic Anti-center

    Science.gov (United States)

    Liu, X.-W.; Yuan, H.-B.; Huo, Z.-Y.; Deng, L.-C.; Hou, J.-L.; Zhao, Y.-H.; Zhao, G.; Shi, J.-R.; Luo, A.-L.; Xiang, M.-S.; Zhang, H.-H.; Huang, Y.; Zhang, H.-W.

    2014-01-01

    As a major component of the LAMOST Galactic surveys, the LAMOST Spectroscopic Survey of the Galactic Anti-center (LSS-GAC) will survey a significant volume of the Galactic thin/thick disks and halo in a contiguous sky area of ~3,400 sq.deg., centered on the Galactic anti-center (|b| ~ 3 M stars of all colors, uniformly and randomly selected from (r, g - r) and (r, r - i) Hess diagrams obtained from a CCD imaging photometric survey of ~5,400 sq.deg. with the Xuyi 1.04/1.20 m Schmidt Telescope, ranging from r = 14.0 to a limiting magnitude of r = 17.8 (18.5 for limited fields). The survey will deliver spectral classification, radial velocity (V r) and stellar parameters (effective temperature (T eff), surface gravity (log g) and metallicity [Fe/H]) for millions of Galactic stars. Together with Gaia which will provide accurate distances and tangential velocities for a billion stars, the LSS-GAC will yield a unique data set to study the stellar populations, chemical composition, kinematics and structure of the disks and their interface with the halo, identify streams of debris of tidally disrupted dwarf galaxies and clusters, probe the gravitational potential and dark matter distribution, map the 3D distribution of interstellar dust extinction, search for rare objects (e.g. extremely metal-poor or hyper-velocity stars), and ultimately advance our understanding of the assemblage of the Milky Way and other galaxies and the origin of regularity and diversity of their properties. The survey was initiated in the fall of 2012 and expected to complete in the spring of 2017. Hitherto, about 0.4 M spectra of S/N(λ7450) >= 10 per pixel have been accumulated. In addition, bright nights have been used to target stars brighter than 14 mag and have so far generated over 0.4 M spectra, yielding an excellent sample of local stars to probe the solar neighborhood. LSP3, a set of pipelines tailored to the need of LSS-GAC, for spectral flux-calibration, and radial velocity and stellar

  18. The New Superfluid Helium Cryostats for the Short Straight Sections of the CERN Large Hadron Collider (LHC)

    CERN Document Server

    Cameron, W; Kurtyka, T; Parma, Vittorio; Renaglia, T; Rifflet, J M; Rohmig, P; Skoczen, Blazej; Tortschanoff, Theodor; Trilhe, P; Védrine, P; Vincent, D

    1998-01-01

    The lattice of the CERN Large Hadron Collider (LHC) contains 364 Short Straight Section (SSS) units, one in every 53 m long half-cell. An SSS consists of three major assemblies: the standard cryostat section, the cryogenic service module, and the jumper connection. The standard cryostat section of an SSS contains the twin aperture high-gradient superconducting quadrupole and two pairs of superconducting corrector magnets, operating in pressurized helium II at 1.9 K. Components for isolating cryostat insulation vacuum, and the cryogenic supply lines, have to be foreseen. Special emphasis is given to the design changes of the SSS following adoption of an external cryogenic supply line (QRL). A jumper connection connects the SSS to the QRL, linking all the cryogenic tubes necessary for the local full-cell cooling loop [at every second SSS]. The jumper is connected to one end of the standard cryostat section via the cryogenic service module, which also houses beam diagnostics, current feedthroughs, and instrument...

  19. Conceptual Design of ILC Damping Ring Wiggler Straight Vacuum System

    International Nuclear Information System (INIS)

    Marks, S.; Kennedy, K.; Plate, D.; Schlueter, R.D.; Zisman, M.

    2007-01-01

    The positron and electron damping rings for the International Linear Collider will contain long straight sections consisting of twenty wiggler/quadrupole pairs. The wigglers will be based upon the CESR superconducting design. There are a number of challenges associated with the design of the wiggler straight vacuum system, in particular, the absorption of photon power generated by the wigglers. This paper will present the overall conceptual design of the wiggler straight vacuum system developed for the ILC Reference Design Report. Particular emphasis will be placed on photon power load calculations and the absorber design

  20. Propagation of ovalization along straight pipes and elbows

    International Nuclear Information System (INIS)

    Millard, A.; Roche, R.L.

    1981-01-01

    The aim of this paper is to present analytical solutions for the propagation of evalization and the variation of the flexibility factor along pipe bends terminated by straight pipes or flanges, under in-plane bending, assuming an elastic material behaviour. The influence of the various strains in analysed in the simple case of a straight pipe, subjected to an elliptical cross-section shape deformation at one end. The results enlighten the very important part played by the distorsion in the propagation. They have been compared with finite elements solutions and with simple experiments. The solution is developed for an elbow terminated by a straight pipe or a flange, following the Von Karman's approach: local displacements are expanded in Fourier series, the coefficients of which vary along the curvilinear abscissa, like the rotation of the cross-section as a whole; the differential equations as well as the boundary conditions are found by minimization of the total potential energy of the assembly. The solutions are compared to existing and experimental results. (orig./HP)

  1. MODELLING SLOW EXTRACTION INDUCED RADIOACTIVITY IN SPS LSS2

    CERN Document Server

    Araujo Martinez, Aurora Cecilia; CERN. Geneva. TE Department

    2017-01-01

    The Accelerator and Beam Transfer (ABT) group is investigating the impact of recent proposals to extract higher proton intensities to Fixed Target experiments at the SPS. The 400 GeV high-energy proton beam is typically extracted over a few seconds using a resonant slow-extraction technique that induces small but unavoidable beam losses on the extraction equipment in SPS LSS2. In this report, the induced radioactivity for 2016-2017 is used to predict future activation levels and cool-down times, using a past intervention as a reference to predict dose to the personnel carrying-out maintenance of the accelerator.

  2. A composite vacuum barrier for the LHC short straight section

    International Nuclear Information System (INIS)

    Jenny, B.; Rohmig, P.; Uriarte, J.M.

    1996-01-01

    The lattice of the CERN Large Hadron Collider (LHC) will contain 384 Short Straight Section (SSS) units, one in every 53 m half-cell. The SSS is composed of a twin aperture high-field superconducting quadrupole and of two combined-function corrector magnets operating in pressurized helium at 1.9 K. The SSS cryostat contains also a barrier for sectorisation of the insulation vacuum. The vacuum barrier is mounted between the helium vessel and the vacuum enclosure. Its functions are to limit the extent of eventual helium leaks and to facilitate the leak detection and the pumping-down from atmospheric pressure. During installation of the LHC, the vacuum barrier permits independent testing of the half-cells, thus enabling higher installation rates. In parallel to a conventional barrier made out of austenitic stainless steel, a barrier of composite material was developed, taking advantage of the lower thermal conductivity of glass fibre reinforced epoxy resin, and with the aim of reducing costs for LHC. The thermo-mechanical design together with the conception and the moulding techniques used for the manufacture of the prototype are described. Bonding techniques for the leak tight stainless steel composite interfaces are presented and test results shown. Results on the mechanical performance and on the helium tests carried out on the prototype are given

  3. Exact equivalent straight waveguide model for bent and twisted waveguides

    DEFF Research Database (Denmark)

    Shyroki, Dzmitry

    2008-01-01

    Exact equivalent straight waveguide representation is given for a waveguide of arbitrary curvature and torsion. No assumptions regarding refractive index contrast, isotropy of materials, or particular morphology in the waveguide cross section are made. This enables rigorous full-vector modeling...... of in-plane curved or helically wound waveguides with use of available simulators for straight waveguides without the restrictions of the known approximate equivalent-index formulas....

  4. First straw straightness measurements on a 4-plane end-cap ATLAS TRT wheel

    CERN Document Server

    Lucotte, A; Mitsou, V A; Mouraviev, S V; Nadtochy, A

    2001-01-01

    This document reports the first results and their interpretation of the straw straightness measurements that have been performed on the first 4-plane end-cap prototype of the ATLAS TRT. Section 2 presents the experimental setup used for the measurements, as well as a review of the data sample used to perform this study. It also provides a description of the method used to assess straw straightness, which is based on the measurements of the maximal gas gain deviation (``straw eccentricity'') seen along the straw. Section 3 reports the results of straw straightness for the 4-plane module, including corrections due to the gas flow. The effect of energy resolution degradation is also explained and results in terms of wire offset are reported. In Section 4, the straw bending due to an applied lateral deformation is measured, and finally Section 5 reviews the conclusions.

  5. Short Straight Sections in the LHC Matching Sections (MS SSS) An Extension of the Arc Cryostats to Fulfil Specific Machine Functionalities

    CERN Document Server

    Parma, V; Lutton, F

    2005-01-01

    The LHC insertions require 50 specific superconducting quadrupoles in the matching sections, operating either in 1.9 K superfluid helium or in boiling helium at 4.5 K. These magnets are assembled together with corrector magnets in cold masses, and are inserted in individual cryostats to form the MS Short Straight Sections (MS SSS). The variety of quadrupoles and corrector magnets leads to 10 families of cold masses, with lengths ranging from 5 to 12 m and weights ranging from 60 to 140 kN. The MS SSS need to fulfil specific requirements related to the collider topology, its cryogenic layout and the powering scheme. Most MS SSS are standalone cryogenic and super-conducting units, i.e. they are not in the continuous arc cryostat, and therefore need dedicated cryogenic and electrical feeding. Specially designed cryostat end-caps are required to close the vacuum vessels at each end, which include low heat in-leak Cold-to-Warm transitions (CWT) for the beam tubes and 6 kA local electrical feedthrough for powering...

  6. Additional Quadrupoles At Center Of Long Straights In The NSLS-II Lattice

    International Nuclear Information System (INIS)

    Lin, F.; Bengtsson, J.; Guo, W.; Krinsky, S.; Li, Y.; Yang, L.

    2011-01-01

    The NSLS-II storage ring lattice is comprised of 30 DBA cells arranged in 15 superperiods. There are 15 long straight sections (9.3m) for injection, RF and insertion devices and 15 shorter straights (6.6m) for insertion devices. In the baseline lattice, the short straights have small horizontal and vertical beta functions but the long straights have large horizontal beta function optimized for injection. In this paper, we explore the possibility of installing additional quadrupoles at the center of selected long straight sections in order to provide two low-beta source locations for undulators in the same straight. The required modification to the linear lattice is discussed as well as the preservation of adequate dynamic aperture required for good injection efficiency and adequate Touschek lifetime. This paper discusses the possibility of producing two low-beta source locations for optimum brightness of undulators in the long straights of NSLS-II lattice by installing additional quadrupoles at the center. The linear optics is optimized to satisfy the requirements of lattice function and properties. Nonlinear optimization for a lattice with working point at (37.16, 17.22) is performed. Considering the magnets misalignment errors and physical apertures, we calculate the frequency maps and plot the tune footprint. The results show that the modified high-low beta function lattice can achieve a modest dynamic aperture in this preliminary study. Further work will continue to expand the dynamic aperture to meet the requirement of good injection efficiency and sufficient Touschek lifetime.

  7. At UA6

    CERN Multimedia

    1983-01-01

    UA6 was setup by the CERN-Lausanne-Michigan-Rockfeller Collaboration to sudy inclusive electromagnetic final states and Lambda production in ppbar and pp interactions at 22.5 GeV c.m. The apparatus consisting of a gas-jet target, spectrometer magnet, and associated detectors was installed at the SPS in the missing magnet straight section upstream of LSS5. Louis Dick stands on the left. in the miss

  8. Damping test results for straight sections of 3-inch and 8-inch unpressurized pipes

    International Nuclear Information System (INIS)

    Ware, A.G.; Thinnes, G.L.

    1984-04-01

    EG and G Idaho is assisting the Nuclear Regulatory Commission and the Pressure Vessel Research Committee in supporting a final position on revised damping values for structural analyses of nuclear piping systems. As part of this program, a series of vibrational tests on unpressurized 3-in. and 8-in. Schedule 40 carbon steel piping was conducted to determine the changes in structural damping due to various parametric effects. The 33-ft straight sections of piping were supported at the ends. Additionally, intermediate supports comprising spring, rod, and constant-force hangers, as well as a sway brace and snubbers, were used. Excitation was provided by low-force-level hammer impacts, a hydraulic shaker, and a 50-ton overhead crane for snapback testing. Data was recorded using acceleration, strain, and displacement time histories. This report presents test results showing the effect of stress level and type of supports on structural damping in piping

  9. Evaluation of RO modules for the SSP ETC/LSS.

    Science.gov (United States)

    Jasionowski, W. J.; Bambenek, R. A.

    1973-01-01

    During the past eight years the NASA Manned Spacecraft Center has supported the development of an Integrated Water and Waste Management System for use in the Space Station Prototype (SSP) Environmental Thermal Control/Life-Support System (ETC/LSS). This system includes the reverse osmosis (RO) process for recycling wash water and the compression distillation process for recovering useable water from urine, urinal flush water, humidity condensate, commode flush water and the wash water concentrated by RO. This paper summarizes the experimental work performed during the past four years to select the best commercially available RO module for this system and to also define which surfactants and germicides are most compatible with the selected module.

  10. Standing "Straight" up to Homophobia: Straight Allies' Involvement in GSAs

    Science.gov (United States)

    Lapointe, Alicia Anne

    2015-01-01

    This qualitative study captures the experiences of four straight allies' and one gay youth involvement in gay--straight alliances (GSAs) at their Ontario, Canada, high schools. Participants' motivations for becoming GSA members and their roles as allies are examined. Queer theoretical perspectives, as espoused by Britzman (1995, 1998) and Linville…

  11. Applying Lean Six Sigma methodology to reduce cesarean section rate.

    Science.gov (United States)

    Chai, Ze-Ying; Hu, Hua-Min; Ren, Xiu-Ling; Zeng, Bao-Jin; Zheng, Ling-Zhi; Qi, Feng

    2017-06-01

    This study aims to reduce cesarean section rate and increase rate of vaginal delivery. By using Lean Six Sigma (LSS) methodology, the cesarean section rate was investigated and analyzed through a 5-phase roadmap consisting of Define, Measure, Analyze, Improve, and Control. The principal causes of cesarean section were identified, improvement measures were implemented, and the rate of cesarean section before and after intervention was compared. After patients with a valid medical reason for cesarean were excluded, the main causes of cesarean section were maternal request, labor pain, parturient women assessment, and labor observation. A series of measures was implemented, including an improved parturient women assessment system, strengthened pregnancy nutrition guidance, implementation of painless labor techniques, enhanced midwifery team building, and promotion of childbirth-assist skills. Ten months after introduction of the improvement measures, the cesarean section rate decreased from 41.83% to 32.00%, and the Six Sigma score (ie, Z value) increased from 1.706 to 1.967 (P < .001). LSS is an effective way to reduce the rate of cesarean section. © 2016 John Wiley & Sons, Ltd.

  12. Axis Measurements, Field Quality and Quench Performance of the First LHC Short Straight Sections

    CERN Document Server

    Sanfilippo, S; Calvi, M; Chohan, V; Durante, M; Hagen, P; Pugnat, P; Smirnov, N; Schnizer, P; Sammut, N; Siemko, A; Simon, F; Stafiniak, A; Todesco, Ezio; Tortschanoff, Theodor; Walckiers, L

    2005-01-01

    The series testing at 1.9 K of the 360 Short Straight Sections (SSS) for the Large Hadron Collider have started at CERN in September 2003. The SSS contain the lattice quadrupoles and correction magnets in a common cryostat. The lattice quadrupoles feature two collared coils with 56 mm bore assembled in a common yoke. The coils are wound in two-layers from 15.1 mm wide NbTi cable, insulated with polyimide tape. The paper reviews the main test results performed in superfluid helium. The magnetic field and magnetic center position of the quadrupoles and associated correctors were measured with two independent systems, namely an automated scanner and a single stretched wire technique. The quench training, the field quality and the magnetic alignment measurements are presented and discussed in terms of the specifications and expected performances of these magnets in the LHC. We discuss in detail the field quality in terms of multipole errors measured at injection and nominal field and decomposed into geometric an...

  13. Ratcheting failure of pressurised straight pipes and elbows under reversed bending

    International Nuclear Information System (INIS)

    Vishnuvardhan, S.; Raghava, G.; Gandhi, P.; Saravanan, M.; Goyal, Sumit; Arora, Punit; Gupta, Suneel K.; Bhasin, Vivek

    2013-01-01

    Ratcheting studies were carried out on Type 304LN stainless steel straight pipes and elbows subjected to steady internal pressure and cyclic bending load. The internal pressure for all the straight pipes was 35 MPa and in the case of elbows the internal pressure was varied for different elbows, ranging from 27.6 MPa to 39.2 MPa. Cyclic bending load was applied on the specimens by subjecting them to different levels of load-line displacement. The specimens have undergone significant ratchet swelling (ballooning), ovalization and consequent thinning of the cross-section during ratcheting. The straight pipes failed either by occurrence of through-wall crack accompanied by simultaneous ballooning, or bursting with simultaneous ballooning. All the elbows failed by occurrence of through-wall crack accompanied by simultaneous ballooning. Ratcheting behaviour of straight pipes and elbows were compared and it was generally inferred that ratcheting was more pronounced in straight pipes than in elbows. -- Graphical abstract: Strain history for the specimen QCE-RAT-6-L1. Highlights: • Studies were carried out under combined internal pressure and cyclic bending. • Ratcheting strains were measured at critical locations of the specimens. • Quantified the percentage of ballooning, ovalization and reduction in thickness. • Modes of ratcheting failure of straight pipes and elbows are studied. • Inferred that ratcheting is more pronounced in straight pipes than in elbows

  14. Effect of a uniform magnetic induction field upon the flow of an electrically conducting fluid placed in a straight rectangular cross section, one of the walls of which, characterized by an infinite conductivity, presents uniform translation movement

    International Nuclear Information System (INIS)

    Herve, Patrick

    1975-01-01

    This is a theoretical study of an electrically viscous fluid flowing in a straight rectangular cross section channel, a wall of which, infinitely conducting, is placed perpendicularly to the direction of a uniform magnetic induction field. The three other walls of the channel being electrically insulating, remain motionless. Formulas giving velocity distribution law in the straight section of the flow in relation to the Hartmann's number, curves illustrating the accelerating effect produced across the whole section, by the application of the magnetic induction field, and example for the distribution of the electric current lines in case of a square section are given [fr

  15. Assessment of New Components to be integrated in the LHC Room Temperature Vacuum System

    CERN Document Server

    Bregliozzi, G; Chiggiato, P

    2014-01-01

    Integration of new equipment in the long straight sections (LSS) of the LHC must be compatible with the TiZrV non-evaporable getter thin film that coats most of the 6-km-long room-temperature beam pipes. This paper focus on two innovative accelerator devices to be installed in the LSS during the long shutdown 1 (LS1): the beam gas vertex (BGV) and a beam bending experiment using a crystal collimator (LUA9). The BGV necessitates a dedicated pressure bump, generated by local gas injection, in order to create the required rate of inelastic beam-gas interactions. The LAU9 experiments aims at improving beam cleaning efficiency with the use of a crystal collimator. New materials like fibre optics, piezoelectric components, and glues are proposed in the original design of the two devices. The integration feasibility of these set-ups in the LSS is presented. In particular outgassing tests of special components, X-rays photoelectron spectroscopy analysis of NEG coating behaviour in presence of glues during bake-out, a...

  16. DFBX boxes -- electrical and cryogenic distribution boxes for the superconducting magnets in the LHC straight sections

    International Nuclear Information System (INIS)

    Zbasnik, Jon P.; Corradi, Carol A.; Gourlay, S.A.; Green, MichaelA.; Hafalia, Aurelio Q.; Kajiyama, Yoichi Jr.; Knolls, Michael J.; LaMantia, Roberto F.; Rasson, Joseph E.; Reavill, Dulie; Turner, William C.

    2002-01-01

    DFBX distribution boxes provide cryogenic and electrical services to superconducting quadrupoles and to a superconducting dipole at either end of four of the long straight sections in the LHC. The DFBX boxes also provide instrumentation and quench protection to the magnets. Current for the quadrupole and the dipole magnet is delivered through leads that combine HTS and gas cooled leads. Current for the 600 A and 120 A correction magnets is provided by pure gas-cooled leads. The bus bars from the leads to the magnets pass through low leak-rate lambda plugs between 1.8 K and 4.4 K. The heat leak into the 1.9 K region from the liquid helium tank is determined by the design of the lambda plugs. This paper describes the DFBX boxes and their function of delivering current and instrumentation signals to the magnets

  17. Cancer and non-cancer mortality risks in atomic bomb survivors, 1950-1997: lSS report 13

    International Nuclear Information System (INIS)

    Shimizu, Y.; Preston, D.L.; Pierce, D.A.; Suyama, A.; Kodama, K.; Mabuchi, K.

    2003-01-01

    The present report continues the series of general reports on mortality in the Life Span Study (LSS) cohort followed by the Radiation Effects Research Foundation (RERF). The present report deals with solid cancer and non-cancer disease mortality during the period from 1950 through 1997, updating with seven additional years of follow-up LSS Report 12. The LSS cohort includes 86,572 people with individual dose estimates. There have been 9,335 deaths from solid cancer and 31,881 deaths from non-cancer disease during the 47 years follow-up. 19% of the solid cancer and 15% of the non-cancer disease deaths occurred during the newly added follow-up period. While excess rates for radiation-associated solid cancers are seen to increase throughout the study period regardless of age at exposure, relative risks are highest for those exposed as children but appear to decline with increasing age. For those exposed at age 30 the solid cancer risk is elevated by 47% at age 70. There are interesting variations by site of age and age at exposure pattern, though the patterns of the risk do not differ statistically from those for solid cancer as a group. However, the interpretation of age at exposure effects on the ERR or the EAR is complicated by changes in background rates with birth cohort or time trend. The evidence for radiation effects on non-cancer mortality remains strong with risks increased by about 14% per Sv during the last thirty years of follow-up. Statistically significant increases are seen for heart disease, stroke, digestive diseases, and respiratory diseases. Although the non-cancer data are consistent with some non-linearity in the dose response, the evidence against linearity is weaker than past. However, there is no direct statistical evidence of radiation effects for doses less than 0.5 Sv

  18. Straight scaling FFAG beam line

    International Nuclear Information System (INIS)

    Lagrange, J.-B.; Planche, T.; Yamakawa, E.; Uesugi, T.; Ishi, Y.; Kuriyama, Y.; Qin, B.; Okabe, K.; Mori, Y.

    2012-01-01

    Fixed field alternating gradient (FFAG) accelerators are recently subject to a strong revival. They are usually designed in a circular shape; however, it would be an asset to guide particles with no overall bend in this type of accelerator. An analytical development of a straight FFAG cell which keeps zero-chromaticity is presented here. A magnetic field law is thus obtained, called “straight scaling law”, and an experiment has been conducted to confirm this zero-chromatic law. A straight scaling FFAG prototype has been designed and manufactured, and horizontal phase advances of two different energies are measured. Results are analyzed to clarify the straight scaling law.

  19. Straight scaling FFAG beam line

    Science.gov (United States)

    Lagrange, J.-B.; Planche, T.; Yamakawa, E.; Uesugi, T.; Ishi, Y.; Kuriyama, Y.; Qin, B.; Okabe, K.; Mori, Y.

    2012-11-01

    Fixed field alternating gradient (FFAG) accelerators are recently subject to a strong revival. They are usually designed in a circular shape; however, it would be an asset to guide particles with no overall bend in this type of accelerator. An analytical development of a straight FFAG cell which keeps zero-chromaticity is presented here. A magnetic field law is thus obtained, called "straight scaling law", and an experiment has been conducted to confirm this zero-chromatic law. A straight scaling FFAG prototype has been designed and manufactured, and horizontal phase advances of two different energies are measured. Results are analyzed to clarify the straight scaling law.

  20. FIXTURING DEVICE FOR DRILLING A STRAIGHT SHAFT

    Directory of Open Access Journals (Sweden)

    SUSAC, Florin

    2017-05-01

    Full Text Available The paper presents a fixturing device used for machining by drilling a straight shaft. The shaft was manufactured on EMCO CONCEPT TURN 55 CNC. The blank used was a bar with circular cross-section. The orientation and fixing scheme of the part and the orientation elements for fixturing device are presented as they were drawn in Autodesk Inventor and AutoCAD software.

  1. Simulation and analysis of the transmission properties of curved-straight neutron guide systems

    International Nuclear Information System (INIS)

    Copley, J.R.D.; Mildner, D.F.R.

    1992-01-01

    This paper reports that the spatial intensity distribution of neutrons emerging from a curved guide is far from uniform, particularly at short wavelengths, and curved guides are sometimes followed by a straight section of guide to make the intensity distribution more uniform. The behavior of neutrons within curved-straight neutron guide systems is examined using both ray-tracing and analytical approaches to the problem. The intensity distribution within the straight guide tends to wash from one side of the guide to the other. The amplitude of this transverse wave decreases with increasing guide length, and the characteristic length of the wave decreases with increasing neutron wavelength

  2. Damping test results for straight sections of 3-inch and 8-inch unpressurized pipes. [PWR; BWR

    Energy Technology Data Exchange (ETDEWEB)

    Ware, A.G.; Thinnes, G.L.

    1984-04-01

    EG and G Idaho is assisting the Nuclear Regulatory Commission and the Pressure Vessel Research Committee in supporting a final position on revised damping values for structural analyses of nuclear piping systems. As part of this program, a series of vibrational tests on unpressurized 3-in. and 8-in. Schedule 40 carbon steel piping was conducted to determine the changes in structural damping due to various parametric effects. The 33-ft straight sections of piping were supported at the ends. Additionally, intermediate supports comprising spring, rod, and constant-force hangers, as well as a sway brace and snubbers, were used. Excitation was provided by low-force-level hammer impacts, a hydraulic shaker, and a 50-ton overhead crane for snapback testing. Data was recorded using acceleration, strain, and displacement time histories. This report presents test results showing the effect of stress level and type of supports on structural damping in piping.

  3. Estimates of power generated from synchrotron radiation in the HL-LHC experimental insertion regions

    CERN Document Server

    Rossi, Adriana; CERN. Geneva. ATS Department

    2017-01-01

    The power generated in single magnets of the HL-LHC experimental regions is estimated for collision optics HLLHCV1.2 β*=15 cm Round and HLLHCV1.2 Flat. Note that the layout used for the computations presented here is that before the recent change of baseline. These values should serve as input to Monte-Carlo codes (i.e., PHOTON [ ], Synrad [ ] or others), able to calculate the heat load distribution along the machine and in particular the Long Straight Sections (LSS).

  4. Low Horizontal Beta Function In Long Straights Of The NSLS-II Lattice

    International Nuclear Information System (INIS)

    Fanglei, L.; Bengtsson, J.; Guo, W.; Krinsky, S.; Li, Y.; Yang, L.

    2011-01-01

    The NSLS-II storage ring lattice is comprised of 30 DBA cells arranged in 15 superperiods. There are 15 long straight sections (9.3m) for injection, RF and insertion devices and 15 short straights (6.6m) for insertion devices. In the baseline lattice, the short straights have small horizontal and vertical beta functions but the long straights have large horizontal beta function optimized for injection. In this paper, we explore the possibility of maintaining three long straights with large horizontal beta function while providing the other 12 long straights with smaller horizontal beta function to optimize the brightness of insertion devices. Our study considers the possible linear lattice solutions as well as characterizing the nonlinear dynamics. Results are reported on optimization of dynamic aperture required for good injection efficiency and adequate Touschek lifetime. This paper discusses dynamic aperture optimization for the NSLS-II lattice with alternate high and low horizontal beta function in the long straights, which is proposed for the optimization of the brightness of insertion devices. The linear optics is optimized to meet the requirements of lattice function and source properties. Nonlinear optimization for a lattice with working point at (37.18, 16.2) is performed. Considering the realistic magnets errors and physical apertures, we calculate the frequency maps and plot the tune footprint. The results show that the lattice with high-low beta function has adequate dynamic aperture for good injection efficiency and sufficient Touschek lifetime.

  5. The XMM-SERVS survey: new XMM-Newton point-source catalog for the XMM-LSS field

    Science.gov (United States)

    Chen, C.-T. J.; Brandt, W. N.; Luo, B.; Ranalli, P.; Yang, G.; Alexander, D. M.; Bauer, F. E.; Kelson, D. D.; Lacy, M.; Nyland, K.; Tozzi, P.; Vito, F.; Cirasuolo, M.; Gilli, R.; Jarvis, M. J.; Lehmer, B. D.; Paolillo, M.; Schneider, D. P.; Shemmer, O.; Smail, I.; Sun, M.; Tanaka, M.; Vaccari, M.; Vignali, C.; Xue, Y. Q.; Banerji, M.; Chow, K. E.; Häußler, B.; Norris, R. P.; Silverman, J. D.; Trump, J. R.

    2018-04-01

    We present an X-ray point-source catalog from the XMM-Large Scale Structure survey region (XMM-LSS), one of the XMM-Spitzer Extragalactic Representative Volume Survey (XMM-SERVS) fields. We target the XMM-LSS region with 1.3 Ms of new XMM-Newton AO-15 observations, transforming the archival X-ray coverage in this region into a 5.3 deg2 contiguous field with uniform X-ray coverage totaling 2.7 Ms of flare-filtered exposure, with a 46 ks median PN exposure time. We provide an X-ray catalog of 5242 sources detected in the soft (0.5-2 keV), hard (2-10 keV), and/or full (0.5-10 keV) bands with a 1% expected spurious fraction determined from simulations. A total of 2381 new X-ray sources are detected compared to previous source catalogs in the same area. Our survey has flux limits of 1.7 × 10-15, 1.3 × 10-14, and 6.5 × 10-15 erg cm-2 s-1 over 90% of its area in the soft, hard, and full bands, respectively, which is comparable to those of the XMM-COSMOS survey. We identify multiwavelength counterpart candidates for 99.9% of the X-ray sources, of which 93% are considered as reliable based on their matching likelihood ratios. The reliabilities of these high-likelihood-ratio counterparts are further confirmed to be ≈97% reliable based on deep Chandra coverage over ≈5% of the XMM-LSS region. Results of multiwavelength identifications are also included in the source catalog, along with basic optical-to-infrared photometry and spectroscopic redshifts from publicly available surveys. We compute photometric redshifts for X-ray sources in 4.5 deg2 of our field where forced-aperture multi-band photometry is available; >70% of the X-ray sources in this subfield have either spectroscopic or high-quality photometric redshifts.

  6. Straight until proven gay: A systematic bias toward straight categorizations in sexual orientation judgments.

    Science.gov (United States)

    Lick, David J; Johnson, Kerri L

    2016-06-01

    Perceivers achieve above chance accuracy judging others' sexual orientations, but they also exhibit a notable response bias by categorizing most targets as straight rather than gay. Although a straight categorization bias is evident in many published reports, it has never been the focus of systematic inquiry. The current studies therefore document this bias and test the mechanisms that produce it. Studies 1-3 revealed the straight categorization bias cannot be explained entirely by perceivers' attempts to match categorizations to the number of gay targets in a stimulus set. Although perceivers were somewhat sensitive to base rate information, their tendency to categorize targets as straight persisted when they believed each target had a 50% chance of being gay (Study 1), received explicit information about the base rate of gay targets in a stimulus set (Study 2), and encountered stimulus sets with varying base rates of gay targets (Study 3). The remaining studies tested an alternate mechanism for the bias based upon perceivers' use of gender heuristics when judging sexual orientation. Specifically, Study 4 revealed the range of gendered cues compelling gay judgments is smaller than the range of gendered cues compelling straight judgments despite participants' acknowledgment of equal base rates for gay and straight targets. Study 5 highlighted perceptual experience as a cause of this imbalance: Exposing perceivers to hyper-gendered faces (e.g., masculine men) expanded the range of gendered cues compelling gay categorizations. Study 6 linked this observation to our initial studies by demonstrating that visual exposure to hyper-gendered faces reduced the magnitude of the straight categorization bias. Collectively, these studies provide systematic evidence of a response bias in sexual orientation categorization and offer new insights into the mechanisms that produce it. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  7. 3-D thermoelastic analysis of the straight section of a PWR hot leg containing a hot spot using BEM

    International Nuclear Information System (INIS)

    Bains, R.S.; Sugimoto, J.

    1995-01-01

    A 3-D steady state thermoelastic analysis using the boundary element method has been successfully employed to investigate the structural response of the straight section of a pressurised water reactor hot leg containing a localised hot spot. With the present severe accident thermal boundary conditions, the analysis produces a nonuniform expansion across the hot leg thickness. This expansion was most predominant on the inner surface, especially at the hot spot location where surface swelling was obtained. Furthermore, the hot spot generates large tangential and axial tensile stresses on the outer surface. These could be detrimental to the integrity of the hot leg by acting as potential sites of crack initiation and subsequent propagation. (orig.)

  8. Secondary Electron Yield Measurements and Groove Chambers Tests in the PEP-II Beam Line Straights Sections

    International Nuclear Information System (INIS)

    Pivi, M

    2008-01-01

    Beam instability caused by the electron cloud has been observed in positron and proton storage rings and it is expected to be a limiting factor in the performance of the positron Damping Ring (DR) of future Linear Colliders such as ILC and CLIC [1, 2]. In the Positron Low Energy Ring (LER) of the PEP-II accelerator, we have installed vacuum chambers with rectangular grooves in a straight magnetic-free section to test this promising possible electron cloud mitigation technique. We have also installed a special chamber to monitor the secondary electron yield of TiN and TiZrV (NEG) coating, Copper, Stainless Steel and Aluminum under the effect of electron and photon conditioning in situ in the beam line. In this paper, we describe the ongoing R and D effort to mitigate the electron cloud effect for the ILC damping ring, the latest results on in situ secondary electron yield conditioning and recent update on the groove tests in PEP-II

  9. Straightness measurement of large machine guideways

    Directory of Open Access Journals (Sweden)

    W. Ptaszyñski

    2011-10-01

    Full Text Available This paper shows the guideway types of large machines and describes problems with their straightness measurement. A short description of straightness measurement methods and the results of investigation in straightness of 10 meter long guideways of a CNC machine by means of the XL-10 Renishaw interferometer are also presented.

  10. Weighted straight skeletons in the plane.

    Science.gov (United States)

    Biedl, Therese; Held, Martin; Huber, Stefan; Kaaser, Dominik; Palfrader, Peter

    2015-02-01

    We investigate weighted straight skeletons from a geometric, graph-theoretical, and combinatorial point of view. We start with a thorough definition and shed light on some ambiguity issues in the procedural definition. We investigate the geometry, combinatorics, and topology of faces and the roof model, and we discuss in which cases a weighted straight skeleton is connected. Finally, we show that the weighted straight skeleton of even a simple polygon may be non-planar and may contain cycles, and we discuss under which restrictions on the weights and/or the input polygon the weighted straight skeleton still behaves similar to its unweighted counterpart. In particular, we obtain a non-procedural description and a linear-time construction algorithm for the straight skeleton of strictly convex polygons with arbitrary weights.

  11. Straight nearness spaces | Bentley | Quaestiones Mathematicae

    African Journals Online (AJOL)

    Straight spaces are spaces for which a continuous map defined on the space which is uniformly continuous on each set of a finite closed cover is then uniformly continuous on the whole space. Previously, straight spaces have been studied in the setting of metric spaces. In this paper, we present a study of straight spaces in ...

  12. Straight sinus thrombosis during neurosurgical operation.

    Science.gov (United States)

    Kawano, Hiroto; Nitta, Naoki; Nozaki, Kazuhiko

    2016-01-01

    Perioperative straight sinus thrombosis is extremely rare. A 59-year-old female was admitted to our department because of incidentally found small anterior cerebral artery (A1) aneurysm with microbleeding. After clipping the cerebral aneurysm, she had delayed emergence from anesthesia, total aphasia, and right hemiparesis. Fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI) of the head showed hyperintensity in the bilateral caudate nuclei, putamina, and thalami, and computed tomography of the head showed a hyperdense straight sinus, suggesting straight sinus thrombosis. Her neurologic symptoms improved gradually, and she achieved a full clinical recovery, with radiological evidence of recanalization of the straight sinus at follow-up. The possibility of straight sinus thrombosis should be considered in postoperative patients with unexplained postoperative deficits when MRI demonstrates hyperintensity in the bilateral basal ganglia and thalami on FLAIR signal images.

  13. IR-safe and UV-safe integrands in the EFTofLSS with exact time dependence

    Energy Technology Data Exchange (ETDEWEB)

    Lewandowski, Matthew [Institut de Physique Théorique, Université Paris Saclay, CEA, CNRS, 91191 Gif-sur-Yvette (France); Senatore, Leonardo, E-mail: matthew.lewandowski@ipht.fr, E-mail: senatore@stanford.edu [Stanford Institute for Theoretical Physics, Stanford University, Stanford, 94306 CA (United States)

    2017-08-01

    Because large-scale structure surveys may very well be the next leading sources of cosmological information, it is important to have a precise understanding of the cosmological observables; for this reason, the Effective Field Theory of Large-Scale Structure (EFTofLSS) was developed. So far, most results in the EFTofLSS have used the so-called Einstein-de Sitter approximation, an approximation of the time dependence which is known to be accurate to better than one percent. However, in order to reach even higher accuracy, the full time dependence must be used. The computation with exact time dependence is sensitive to both infrared (IR) and ultraviolet (UV) effects in the loop integrands, and while these effects must cancel because of diffeomorphism invariance, they make numerical computation much less efficient. We provide a formulation of the one-loop, equal-time exact-time-dependence power spectrum of density perturbations which is manifestly free of these spurious IR and UV divergences at the level of the integrand. We extend our results to the total matter mode with clustering quintessence, show that IR and UV divergences cancel, and provide the associated IR- and UV-safe integrand. This also establishes that the consistency conditions are satisfied in this system. We then use our one-loop result to do an improved precision comparison of the two-loop dark-matter power spectrum with the Dark Sky N -body simulation.

  14. The Assembly of the LHC Short Straight Sections at CERN Work Organization, Quality Assurance and Lessons Learned

    CERN Document Server

    Bourcey, N; López, R; Poncet, A; Parma, V

    2007-01-01

    After 4 years of activity, the assembly of approximately 500 Short Straight Sections (SSS) for the LHC has come to an end at the beginning of 2007. This activity, which was initially foreseen in European industry, was in-sourced at CERN because of the insolvency of the prime contractor. While the quadrupole cold masses were produced in industry, the assembly within their cryostats was transferred to CERN and executed by an external company under a result-oriented contract. CERN procured cryostat components, set up a dedicated 2000 m2 assembly hall with all the specific assembly equipment and tooling and defined the assembly and testing procedures. The contractor took up responsibility for the delivery, on time, of assemblies according to the required quality. A dedicated CERN production and quality assurance team was constituted. A specific quality assurance plan was set up involving 2 additional contractors responsible for weld inspections on a total of about 20'000 assembly welds and the execution of about ...

  15. Energy Deposition in a Septum Wire

    CERN Document Server

    Ferioli, G; Knaus, P; Koopman, J; CERN. Geneva. SPS and LHC Division

    2001-01-01

    The present note describes a machine development (MD) aimed to confirm experimentally the need for protection of the extraction wire septum ZS in SPS long straight section LSS6 during LHC operation. Single wires identical to the ones mounted on the extraction septum were fixed on a fast wire scanner and put into the beam path. The beam heated the wire until it broke after a measured number of turns. The maximum single shot intensity the septum wires could withstand was thus calculated and compared with simulation results.

  16. Roundness and straightness measurement of ceramic beam ducts for the 3 GeV-synchrotron

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, Daiji; Kinsho, Michikazu; Kanazawa, Kenichiro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Kubo, Tomio; Sato, Yoshihiro; Saito, Yoshio [High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan)

    2001-12-01

    Large aperture ({phi}200 - {phi}250) cylindrical beam ducts consisting of alumina ceramics will be used in the 3 GeV-synchrotron of High Intensity Proton Accelerator Facility. In particular, bending magnet sections require the large length ({approx}3500 mm) ceramic beam duct connecting several unit ducts whose length is around 500-1000 mm by metallizing and glazing. Therefore it is very important to evaluate roundness and straightness of ceramic ducts because we have to compensate contact area large and have to minimize misalignment of ducts connected. We developed an apparatus for measuring roundness and straightness, and we completed data analysis method using general application software Excel as well as measuring method. Then we have taken data, and have evaluated value of roundness and straightness for the first time about 7 pieces (3 kinds) of ceramic beam duct. At last we have found out that unit ceramic ducts can be made after sintering without polishing with roundness several hundred micron ({mu}m) and straightness around 0.2-1 mm, and that straightness has a tendency to become large as duct length increases as well as roundness increases directly proportional to the maximum oblateness. (author)

  17. Proposal to negotiate an amendment to an existing contract for the supply of the cold masses of the LHC short straight sections

    CERN Document Server

    2006-01-01

    This document concerns the proposal to negotiate an amendment to an existing contract for the supply of the main superconducting quadrupoles and assembly of the cold masses of the LHC short straight sections. For the reasons explained in this document, the Finance Committee is invited to approve an amendment to an existing contract with the firm ACCEL INSTRUMENTS (DE) for an amount of 1 513 618 euros (2 411 496 Swiss francs), bringing the total to a maximum amount of 40 815 743 euros (65 027 641 Swiss francs), subject to revision for inflation. The amount in Swiss francs has been calculated using the present rate of exchange.

  18. 26 CFR 1.9001-1 - Change from retirement to straight-line method of computing depreciation.

    Science.gov (United States)

    2010-04-01

    ... of computing depreciation. 1.9001-1 Section 1.9001-1 Internal Revenue INTERNAL REVENUE SERVICE....9001-1 Change from retirement to straight-line method of computing depreciation. (a) In general. The... of deductions for the depreciation of those roadway assets which are defined in this section as...

  19. Synthesis and characterization of straight and stacked-sheet AlN nanowires with high purity

    International Nuclear Information System (INIS)

    Lei, M.; Yang, H.; Li, P.G.; Tang, W.H.

    2008-01-01

    Large-scale AlN nanowires with hexagonal crystal structure were synthesized by the direct nitridation method at high temperatures. The experimental results indicate that these single-crystalline AlN nanowires have high purity and consist of straight and stacked-sheet nanowires. It is found that straight AlN nanowire grows along [1, 1, -2, 0] direction, whereas the stacked-sheet nanowire with hexagonal cross section is along [0 0 0 1] direction. It is thought that vapor-solid (VS) mechanism should be responsible for the growth of AlN nanowires

  20. The licensing support system (LSS): Who should operate it and will it work?

    International Nuclear Information System (INIS)

    Macnabb, M.L.; Pflum, C.

    1991-01-01

    The development of the mammoth Licensing Support System (LSS), a management information system intended to handle documentation relevant to the licensing application of the DOE for the High Level Nuclear Waste Repository is not conforming to statute, regulation or intent. At the present stage of its development, it is a quagmire of legal, regulatory and technical difficulties which has the DOE and the NRC arguing over its implementation and budget. This paper examines some of the failures of the system and concludes that many of the DOE functions should now be transferred to a disinterested and independent third party under the auspices of the NRC in order to meet the intent of its creators

  1. Straight and White: Talking with My Mouth Full

    Science.gov (United States)

    Myers, W. Benjamin

    2008-01-01

    By using straight and white teeth as a metaphor for a straight and White identity, the author reflects on how this identity is performed, maintained, and often problematic. Using literature about identity performance, three different voices speak to and from straight and White identity. Using irony by blending arrogance and ignorance in the voice…

  2. A Faster Algorithm for Computing Straight Skeletons

    KAUST Repository

    Cheng, Siu-Wing

    2014-09-01

    We present a new algorithm for computing the straight skeleton of a polygon. For a polygon with n vertices, among which r are reflex vertices, we give a deterministic algorithm that reduces the straight skeleton computation to a motorcycle graph computation in O(n (logn)logr) time. It improves on the previously best known algorithm for this reduction, which is randomized, and runs in expected O(n√h+1log2n) time for a polygon with h holes. Using known motorcycle graph algorithms, our result yields improved time bounds for computing straight skeletons. In particular, we can compute the straight skeleton of a non-degenerate polygon in O(n (logn) logr + r 4/3 + ε ) time for any ε > 0. On degenerate input, our time bound increases to O(n (logn) logr + r 17/11 + ε ).

  3. A Faster Algorithm for Computing Straight Skeletons

    KAUST Repository

    Mencel, Liam A.

    2014-05-06

    We present a new algorithm for computing the straight skeleton of a polygon. For a polygon with n vertices, among which r are reflex vertices, we give a deterministic algorithm that reduces the straight skeleton computation to a motorcycle graph computation in O(n (log n) log r) time. It improves on the previously best known algorithm for this reduction, which is randomised, and runs in expected O(n √(h+1) log² n) time for a polygon with h holes. Using known motorcycle graph algorithms, our result yields improved time bounds for computing straight skeletons. In particular, we can compute the straight skeleton of a non-degenerate polygon in O(n (log n) log r + r^(4/3 + ε)) time for any ε > 0. On degenerate input, our time bound increases to O(n (log n) log r + r^(17/11 + ε))

  4. A Faster Algorithm for Computing Straight Skeletons

    KAUST Repository

    Cheng, Siu-Wing; Mencel, Liam A.; Vigneron, Antoine E.

    2014-01-01

    We present a new algorithm for computing the straight skeleton of a polygon. For a polygon with n vertices, among which r are reflex vertices, we give a deterministic algorithm that reduces the straight skeleton computation to a motorcycle graph computation in O(n (logn)logr) time. It improves on the previously best known algorithm for this reduction, which is randomized, and runs in expected O(n√h+1log2n) time for a polygon with h holes. Using known motorcycle graph algorithms, our result yields improved time bounds for computing straight skeletons. In particular, we can compute the straight skeleton of a non-degenerate polygon in O(n (logn) logr + r 4/3 + ε ) time for any ε > 0. On degenerate input, our time bound increases to O(n (logn) logr + r 17/11 + ε ).

  5. A straightness error measurement method matched new generation GPS

    International Nuclear Information System (INIS)

    Zhang, X B; Lu, H; Jiang, X Q; Li, Z

    2005-01-01

    The axis of the non-diffracting beam produced by an axicon is very stable and can be adopted as the datum line to measure the spatial straightness error in continuous working distance, which may be short, medium or long. Though combining the non-diffracting beam datum-line with LVDT displace detector, a new straightness error measurement method is developed. Because the non-diffracting beam datum-line amends the straightness error gauged by LVDT, the straightness error is reliable and this method is matchs new generation GPS

  6. Greater Engagement among Members of Gay-Straight Alliances: Individual and Structural Contributors

    Science.gov (United States)

    Poteat, V. Paul; Heck, Nicholas C.; Yoshikawa, Hirokazu; Calzo, Jerel P.

    2016-01-01

    Using youth program models to frame the study of Gay-Straight Alliances (GSAs), we identified individual and structural predictors of greater engagement in these settings with a cross-sectional sample of 295 youth in 33 GSAs from the 2014 Massachusetts GSA Network Survey (69% LGBQ, 68% cisgender female, 68% White, M[subscript age] =16.07).…

  7. 21 CFR 82.5 - General specifications for straight colors.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false General specifications for straight colors. 82.5... LISTING OF CERTIFIED PROVISIONALLY LISTED COLORS AND SPECIFICATIONS General Provisions § 82.5 General specifications for straight colors. No batch of a straight color listed in subpart B, C, or D shall be certified...

  8. Equilibrium depth of scour at straight guide banks

    Science.gov (United States)

    Gjunsburgs, B.; Bulankina, V.

    2017-10-01

    The equilibrium stage of scour at the head of straight guide banks with a uniform and stratified bed conditions have been studied. The contraction of the river by bridge crossing with straight guide banks considerably alters the flow pattern. The streamlines become curve and the concentration of streamlines, longitudinal and transverse slopes of the water surface, a local increase in velocity, vortex and eddy structures, and the origin of a flow separation zone between the extreme streamlines and the guide bank are observed and local scour is developing at the head of the straight guide banks. New formulae for calculation of equilibrium depth of scour at straight guide banks at uniform and stratified river bed is elaborated and confirmed by tests and computer modelling results.

  9. Attitudes toward straight, gay male, and transsexual parenting.

    Science.gov (United States)

    Weiner, Brittany A; Zinner, Leah

    2015-01-01

    This study examined American attitudes toward transsexual and gay male parenting, compared to straight parenting. After reporting levels of transphobia, participants read a vignette regarding a couple seeking child adoption. Individuals high in transphobia perceived nontraditional couples as more emotionally unstable than straight couples and were less willing to grant custody of a child to the nontraditional couples vs. the straight couples. In addition, the transsexual couple faced more prejudice and discrimination than the gay male couple. Implications of these findings are discussed.

  10. Straight Talk for Good Health | NIH MedlinePlus the Magazine

    Science.gov (United States)

    ... of this page please turn Javascript on. Feature: Straight Talk for Good Health Straight Talk for Good Health Past Issues / Spring 2013 ... with your Doctor nihseniorhealth.gov/talkingwithyourdoctor/toc.html Straight talk with your healthcare provider is important. You ...

  11. Straight leg elevation to rule out pelvic injury.

    Science.gov (United States)

    Bolt, Caroline; O'Keeffe, Francis; Finnegan, Pete; Dickson, Kristofer; Smit, De Villiers; Fitzgerald, Mark C; Mitra, Biswadev

    2018-02-01

    Pelvic x-ray is frequently used as a screening tool during initial assessment of injured patients. However routine use in the awake and alert blunt trauma patient may be questioned due to low yield. We propose a clinical tool that may avoid unnecessary imaging by examining whether the ability to straight leg raise, without pain, can rule out pelvic injury. We conducted a prospective cohort study with the exposure variables of ability to straight leg raise and presence of pain on doing so, and presence of pelvic fracture on x-ray as the primary outcome variable. Of the 328 participants, 35 had pelvic fractures, and of these 32 were either unable to straight leg raise, or had pain on doing so, with a sensitivity of 91.43% (95% CI: 76.94-98.2%) and a negative predictive value of 98.57% (95% CI: 95.88-99.70%). The 3 participants with a pelvic fracture who could straight leg raise with no pain, all had a GCS of less than 15, and therefore, among the sub-group of patients with GCS15, a 100% sensitivity and 100% negative predictive value for straight leg raise with no pain to rule out pelvic fracture was demonstrated. Among awake, alert patients, painless straight leg raise can exclude pelvic fractures and be incorporated into initial examination during reception and resuscitation of injured patients. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  12. Modeling analyses of two-phase flow instabilities for straight and helical tubes in nuclear power plants

    International Nuclear Information System (INIS)

    Dong, Ruiting; Niu, Fenglei; Zhou, Yuan; Yu, Yu; Guo, Zhangpeng

    2016-01-01

    Highlights: • Two-phase flow instabilities in straight and helical tubes were studied. • The effects of system pressure, mass flux, inlet subcooling on DWO were studied. • The simulation results are consistent with the experimental results. • The RELAP5 results are consistent with frequency domain method results. - Abstract: The effects of system pressure, mass flux and inlet subcooling on two-phase flow instability for the test section consisted of two heated straight channels or two helical channels are studied by means of RELAP5/MOD3.3 and multi-variable frequency domain control theory. The experimental data in two straight channels are used to verify the RELAP5 and multi-variable frequency domain control theory results. The thermal hydraulic behaviors and parametric effects are simulated and compared with the experimental data. The RELAP5 results show that the flow stability increases with the system pressure, mass velocity, and inlet subcooling at high subcoolings. The frequency domain theory presents the same results as those given by the time domain theory (RELAP5). The effects of system pressure, mass velocity and inlet subcooling are simulated to find the difference between the straight and the helical tube flows. The RELAP5 and the multi-variable frequency domain control theory are used in modeling and simulating density wave oscillation to study their advantages and disadvantages in straight and helical tubes.

  13. Modeling analyses of two-phase flow instabilities for straight and helical tubes in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Ruiting [Beijing Key Laboratory of Passive Nuclear Power Safety and Technology, North China Electric Power University, Beijing 102206 (China); Niu, Fenglei, E-mail: niufenglei@ncepu.edu.cn [Beijing Key Laboratory of Passive Nuclear Power Safety and Technology, North China Electric Power University, Beijing 102206 (China); Zhou, Yuan [School of Nuclear Science and Engineering, Shanghai Jiaotong University, Shanghai 200240 (China); Yu, Yu; Guo, Zhangpeng [Beijing Key Laboratory of Passive Nuclear Power Safety and Technology, North China Electric Power University, Beijing 102206 (China)

    2016-10-15

    Highlights: • Two-phase flow instabilities in straight and helical tubes were studied. • The effects of system pressure, mass flux, inlet subcooling on DWO were studied. • The simulation results are consistent with the experimental results. • The RELAP5 results are consistent with frequency domain method results. - Abstract: The effects of system pressure, mass flux and inlet subcooling on two-phase flow instability for the test section consisted of two heated straight channels or two helical channels are studied by means of RELAP5/MOD3.3 and multi-variable frequency domain control theory. The experimental data in two straight channels are used to verify the RELAP5 and multi-variable frequency domain control theory results. The thermal hydraulic behaviors and parametric effects are simulated and compared with the experimental data. The RELAP5 results show that the flow stability increases with the system pressure, mass velocity, and inlet subcooling at high subcoolings. The frequency domain theory presents the same results as those given by the time domain theory (RELAP5). The effects of system pressure, mass velocity and inlet subcooling are simulated to find the difference between the straight and the helical tube flows. The RELAP5 and the multi-variable frequency domain control theory are used in modeling and simulating density wave oscillation to study their advantages and disadvantages in straight and helical tubes.

  14. LSS, a problem solving skill for graduates and SMEs: Case Study of investigation in a UK Business School curriculum

    OpenAIRE

    Shokri, Alireza; Nabhani, Farhad

    2015-01-01

    Purpose - This research aims to investigate the feasibility of a systematic Lean Six Sigma (LSS) education through the curriculum of business schools to respond to the existing gap between the graduate’s expectation of employability and skill requirements by the Small and Medium Sized Enterprises (SMEs).\\ud \\ud Design/approach/methodology - One UK business school has been used as a case study to conduct an extensive module and programme review followed by a semi-structured interview with the ...

  15. Wind tunnel study of helical and straight-bladed vertical-axis wind turbine wakes

    Science.gov (United States)

    Bagheri, Maryam; Araya, Daniel

    2017-11-01

    It is hypothesized that blade curvature can serve as a passive means to control fluid entrainment and wake recovery in vertical-axis wind turbine (VAWT) arrays. We test this experimentally in a wind tunnel using two different VAWT configurations, one with straight blades and another with helical blades, keeping all other experimental parameters fixed. A small-scale, commercially available VAWT (15W max power) is used as the baseline wind tunnel model in each case. The commercial VAWT blades are replaced with either straight or helical blades that are 3D-printed extrusions of the same airfoil cross-section. Results from smoke flow visualization, three-component wake velocity measurements, and turbine power data are presented. These results give insight into the potential use of VAWTs with curved blades in utility-scale wind farms.

  16. Visual straight-ahead preference in saccadic eye movements.

    Science.gov (United States)

    Camors, Damien; Trotter, Yves; Pouget, Pierre; Gilardeau, Sophie; Durand, Jean-Baptiste

    2016-03-15

    Ocular saccades bringing the gaze toward the straight-ahead direction (centripetal) exhibit higher dynamics than those steering the gaze away (centrifugal). This is generally explained by oculomotor determinants: centripetal saccades are more efficient because they pull the eyes back toward their primary orbital position. However, visual determinants might also be invoked: elements located straight-ahead trigger saccades more efficiently because they receive a privileged visual processing. Here, we addressed this issue by using both pro- and anti-saccade tasks in order to dissociate the centripetal/centrifugal directions of the saccades, from the straight-ahead/eccentric locations of the visual elements triggering those saccades. Twenty participants underwent alternating blocks of pro- and anti-saccades during which eye movements were recorded binocularly at 1 kHz. The results confirm that centripetal saccades are always executed faster than centrifugal ones, irrespective of whether the visual elements have straight-ahead or eccentric locations. However, by contrast, saccades triggered by elements located straight-ahead are consistently initiated more rapidly than those evoked by eccentric elements, irrespective of their centripetal or centrifugal direction. Importantly, this double dissociation reveals that the higher dynamics of centripetal pro-saccades stem from both oculomotor and visual determinants, which act respectively on the execution and initiation of ocular saccades.

  17. Straight eye for the gay guy: composing queerness.

    Science.gov (United States)

    Alexander, Jonathan

    2010-01-01

    Drawing on the work of Didier Eribon and his theorization of the construction of gay male subjectivity, this article examines different "texts," broadly defined, that grapple specifically with straight men attempting to represent male homosexuality: Norman Mailer's essay, "The Homosexual Villain"; the Bravo reality television series Boy Meets Boy, and Michael Griffith's short story, "Hooper Gets a Perm." These texts represent attempts by straight authors to grapple with queer experience in ways that move the imagination of queers beyond simple stereotypes or uncritical explorations of the sexual "other." In the process of examining these texts, the following questions are addressed: What happens when a straight man attempts to represent a gay man? Does he "get it right," and is such a question even useful? More specifically, what is the value in having straights imagine queerness? Is such an imagining possible? Is such desirable? And, if so, what are the contours of such an imagining-as well as its possibilities and limitations, pedagogically, personally, and politically? Ultimately, I contend that the straight imagining of queerness offers rich potential for mutual understanding; furthermore, attempting to understand what goes into the making of those representations tells us much about how queerness circulates in our culture as a subject, a figure of discussion, contention, and representation.

  18. Uncertainty of spatial straightness in 3D measurement

    International Nuclear Information System (INIS)

    Wang Jinxing; Jiang Xiangqian; Ma Limin; Xu Zhengao; Li Zhu

    2005-01-01

    The least-square method is commonly employed to verify the spatial straightness in actual three-dimensional measurement process, but the uncertainty of the verification result is usually not given by the coordinate measuring machines. According to the basic principle of spatial straightness least-square verification and the uncertainty propagation formula given by ISO/TS 14253-2, a calculation method for the uncertainty of spatial straightness least-square verification is proposed in this paper. By this method, the coefficients of the line equation are regarded as a statistical vector, so that the line equation, the result of the spatial straightness verification and the uncertainty of the result can be obtained after the expected value and covariance matrix of the vector are determined. The method not only assures the integrity of the verification result, but also accords with the requirement of the new generation of GPS standards, which can improve the veracity of verification

  19. The Theory and Assessment of Spatial Straightness Error Matched New Generation GPS

    International Nuclear Information System (INIS)

    Zhang, X B; Sheng, X L; Jiang, X Q; Li, Z

    2006-01-01

    In order to assess spatial straightness error matched new generation Dimensional Geometrical Product Specification and Verification (GPS), the theory of spatial straightness error assessing is proposed and its advantages are analyzed based on metrology and statistics in this paper. Then, the assessing parameter system is proposed and it is testified in real application comparing to assessment result of the geometric tolerance theory. Statistical parameters of this assessing system post the different characteristics of spatial straightness error, and can reveal the impact of spatial straightness error on the accessory function more roundly to complement the single assessing parameter of geometrical tolerance for straightness error. The statistical spatial straightness tolerance and statistical spatial straightness error proposed in this paper is possible to be applied in evaluation of other error of form, orientation, location and run-out

  20. AXAOTHER XL -- A spreadsheet for determining doses for incidents caused by tornadoes or high-velocity straight winds

    International Nuclear Information System (INIS)

    Simpkins, A.A.

    1996-09-01

    AXAOTHER XL is an Excel Spreadsheet used to determine dose to the maximally exposed offsite individual during high-velocity straight winds or tornado conditions. Both individual and population doses may be considered. Potential exposure pathways are inhalation and plume shine. For high-velocity straight winds the spreadsheet has the capability to determine the downwind relative air concentration, however for the tornado conditions, the user must enter the relative air concentration. Theoretical models are discussed and hand calculations are performed to ensure proper application of methodologies. A section has also been included that contains user instructions for the spreadsheet

  1. Radical heterosexuality: Straight teacher activism in schools : Does ally-led activism work?

    Directory of Open Access Journals (Sweden)

    Leigh Potvin

    2016-06-01

    Here, I explore the efficacy of straight teacher allies, the importance of understanding straight privilege, and the significance of radical heterosexuality for straight people doing LGBTQ activism. Relying on queer theory and decolonizing/Indigenous queer theory, I argue that it is necessary for straight teachers to acknowledge their straight privilege in order to challenge homophobia's companions: heterosexism and heteronormativity. In addressing the latter two covert forms of oppression in schools, teachers and students could shift into deeper, more effective resistance measures.

  2. Bent versus straight tips in micropulsed longitudinal phacoemulsification.

    Science.gov (United States)

    Stagg, Brian C; Gupta, Isha; Cahoon, Judd; Ronquillo, Cecinio; Shi, Dallas; Zaugg, Brian; Gardiner, Gareth; Barlow, William R; Pettey, Jeff H; Aabid Farukhi, M; Jensen, Jason; Olson, Randall J

    2015-10-01

    The aim of this study was to evaluate bent and straight phacoemulsification tips to determine which tip is more efficient in removal of lens fragments, using micropulsed longitudinal ultrasound in phacoemulsification. In vitro laboratory study. The John A. Moran Eye Center Laboratories, University of Utah, Salt Lake City, Utah, was the study setting. Pig lenses hardened in a manner comparable with dense human cataracts were cut into 2-mm cubes and removed with micropulsed longitudinal ultrasound using settings previously shown to be optimally efficient (6 milliseconds on and 6 milliseconds off for a bent tip). To verify this time as most efficient for a straight tip, we also tested times of 5, 6, and 7 milliseconds time on and off. The tips were either straight or with a 20-degree bend. Twenty cubes were used for each comparative run. For the straight tip, 6 milliseconds on (1.56 ± 0.815 seconds) was significantly more efficient than 7 milliseconds on (2.45 ± 1.56 seconds, p = 0.001) and not significantly more efficient than 5 milliseconds on (1.69 ± 0.86 seconds, p = 0.43). Five milliseconds off time (1.45 ± 0.76s) was more efficient than 6 milliseconds (2.06 ± 1.37 seconds, p = 0.004) and 7 milliseconds off (2.18 ± 1.24s, p = 0.001). The straight tip was more efficient than the bent tip (1.38 ± 0.83 versus 2.93 ± 2.14 seconds, p = 0.006). Results are contrary to accepted common belief. Micropulsed longitudinal phacoemulsification is more efficient with a straight rather than a bent tip. Copyright © 2015 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  3. Straight-Line: A nuclear material storage information management system

    International Nuclear Information System (INIS)

    Nilsen, C.; Mangan, D.

    1995-01-01

    Sandia National Laboratories is developing Straight-Line -- a pilot system to demonstrate comprehensive monitoring of nuclear material in storage. Straight-Line is an integrated system of sensors providing information that will enhance the safety, security, and international accountability of stored nuclear material. The goals of this effort are to: (1) Provide the right sensor information to the right user immediately. (2) Reduce the expenses, risks, and frequency of human inspection of the material. (3) Provide trustworthy data to international inspectors to minimize their need to make on site inspections. In pursuit of these goals, Straight-Line unites technology from Sandia's Authenticated Item Monitoring System (AIMS) and other programs to communicate the authenticated status of the monitored item back to central magazine receivers. Straight-Line, however, incorporates several important features not found in previous systems: (1) Information Security -- the ability to collect and safely disseminate both classified and unclassified sensor data to users on a need-to-know basis. (2) Integrate into a single system the monitoring needs of safety, security, and international accountability. (3) Incorporate the use of sensors providing analog or digital output. This paper will present the overall architecture and status of the Straight-Line project

  4. Straight-Line: A nuclear material storage information management system

    Energy Technology Data Exchange (ETDEWEB)

    Nilsen, C.; Mangan, D.

    1995-07-01

    Sandia National Laboratories is developing Straight-Line -- a pilot system to demonstrate comprehensive monitoring of nuclear material in storage. Straight-Line is an integrated system of sensors providing information that will enhance the safety, security, and international accountability of stored nuclear material. The goals of this effort are to: (1) Provide the right sensor information to the right user immediately. (2) Reduce the expenses, risks, and frequency of human inspection of the material. (3) Provide trustworthy data to international inspectors to minimize their need to make on site inspections. In pursuit of these goals, Straight-Line unites technology from Sandia`s Authenticated Item Monitoring System (AIMS) and other programs to communicate the authenticated status of the monitored item back to central magazine receivers. Straight-Line, however, incorporates several important features not found in previous systems: (1) Information Security -- the ability to collect and safely disseminate both classified and unclassified sensor data to users on a need-to-know basis. (2) Integrate into a single system the monitoring needs of safety, security, and international accountability. (3) Incorporate the use of sensors providing analog or digital output. This paper will present the overall architecture and status of the Straight-Line project.

  5. Faller Classification in Older Adults Using Wearable Sensors Based on Turn and Straight-Walking Accelerometer-Based Features.

    Science.gov (United States)

    Drover, Dylan; Howcroft, Jennifer; Kofman, Jonathan; Lemaire, Edward D

    2017-06-07

    Faller classification in elderly populations can facilitate preventative care before a fall occurs. A novel wearable-sensor based faller classification method for the elderly was developed using accelerometer-based features from straight walking and turns. Seventy-six older individuals (74.15 ± 7.0 years), categorized as prospective fallers and non-fallers, completed a six-minute walk test with accelerometers attached to their lower legs and pelvis. After segmenting straight and turn sections, cross validation tests were conducted on straight and turn walking features to assess classification performance. The best "classifier model-feature selector" combination used turn data, random forest classifier, and select-5-best feature selector (73.4% accuracy, 60.5% sensitivity, 82.0% specificity, and 0.44 Matthew's Correlation Coefficient (MCC)). Using only the most frequently occurring features, a feature subset (minimum of anterior-posterior ratio of even/odd harmonics for right shank, standard deviation (SD) of anterior left shank acceleration SD, SD of mean anterior left shank acceleration, maximum of medial-lateral first quartile of Fourier transform (FQFFT) for lower back, maximum of anterior-posterior FQFFT for lower back) achieved better classification results, with 77.3% accuracy, 66.1% sensitivity, 84.7% specificity, and 0.52 MCC score. All classification performance metrics improved when turn data was used for faller classification, compared to straight walking data. Combining turn and straight walking features decreased performance metrics compared to turn features for similar classifier model-feature selector combinations.

  6. Scalar localization by cone-beam computed tomography of cochlear implant carriers: a comparative study between straight and periomodiolar precurved electrode arrays.

    Science.gov (United States)

    Boyer, Eric; Karkas, Alexandre; Attye, Arnaud; Lefournier, Virginie; Escude, Bernard; Schmerber, Sebastien

    2015-03-01

    To compare the incidence of dislocation of precurved versus straight flexible cochlear implant electrode arrays using cone-beam computed tomography (CBCT) image analyses. Consecutive nonrandomized case-comparison study. Tertiary referral center. Analyses of patients' CBCT images after cochlear implant surgery. Precurved and straight flexible electrode arrays from two different manufacturers were implanted. A round window insertion was performed in most cases. Two cases necessitated a cochleostomy. The patients' CBCT images were reconstructed in the coronal oblique, sagittal oblique, and axial oblique section. The insertion depth angle and the incidence of dislocation from the scala tympani to the scala vestibuli were determined. The CBCT images and the incidence of dislocation were analyzed in 54 patients (61 electrode arrays). Thirty-one patients were implanted with a precurved perimodiolar electrode array and 30 patients with a straight flexible electrode array. A total of nine (15%) scalar dislocations were observed in both groups. Eight (26%) scalar dislocations were observed in the precurved array group and one (3%) in the straight array group. Dislocation occurred at an insertion depth angle between 170 and 190 degrees in the precurved array group and at approximately 370 degrees in the straight array group. With precurved arrays, dislocation usually occurs in the ascending part of the basal turn of the cochlea. With straight flexible electrode arrays, the incidence of dislocation was lower, and it seems that straight flexible arrays have a higher chance of a confined position within the scala tympani than perimodiolar precurved arrays.

  7. Straight-Line -- A nuclear material storage information management system

    International Nuclear Information System (INIS)

    Nilsen, C.; Mangan, D.

    1995-01-01

    Sandia National Laboratories is developing Straight-Line -- a pilot system to demonstrate comprehensive monitoring of nuclear material in storage. Straight-Line is an integrated system of sensors providing information that will enhance the safety, security, and international accountability of stored nuclear material. The goals of this effort are to (1) Provide the right sensor information to the right user in a timely manner. (2) Reduce the expenses, risks, and frequency of human inspection of the material. (3) Provide trustworthy data to international inspectors to minimize their need to make on site inspections. In pursuit of these goals, Straight-Line unites technology from Sandia's Authenticated Item Monitoring System (AIMS) and other programs to communicate the authenticated status of the monitored item back to central magazine receivers. Straight-Line, however, incorporates several important features not found in previous systems: (1) Information Security -- the ability to collect and safely disseminate both classified and unclassified sensor data to users on a need-to-know basis. (2) Integrate into a single system the monitoring needs of safety, security, and international accountability. (3) Incorporate the use of sensors providing analog or digital output. This paper will present the overall architecture and status of the Straight-Line project

  8. Straight-Line -- A nuclear material storage information management system

    Energy Technology Data Exchange (ETDEWEB)

    Nilsen, C. [Sandia National Labs., Livermore, CA (United States); Mangan, D. [Sandia National Labs., Albuquerque, NM (United States)

    1995-12-31

    Sandia National Laboratories is developing Straight-Line -- a pilot system to demonstrate comprehensive monitoring of nuclear material in storage. Straight-Line is an integrated system of sensors providing information that will enhance the safety, security, and international accountability of stored nuclear material. The goals of this effort are to (1) Provide the right sensor information to the right user in a timely manner. (2) Reduce the expenses, risks, and frequency of human inspection of the material. (3) Provide trustworthy data to international inspectors to minimize their need to make on site inspections. In pursuit of these goals, Straight-Line unites technology from Sandia`s Authenticated Item Monitoring System (AIMS) and other programs to communicate the authenticated status of the monitored item back to central magazine receivers. Straight-Line, however, incorporates several important features not found in previous systems: (1) Information Security -- the ability to collect and safely disseminate both classified and unclassified sensor data to users on a need-to-know basis. (2) Integrate into a single system the monitoring needs of safety, security, and international accountability. (3) Incorporate the use of sensors providing analog or digital output. This paper will present the overall architecture and status of the Straight-Line project.

  9. Straight line closure of congenital macrostomia

    Directory of Open Access Journals (Sweden)

    Schwarz Richard

    2004-01-01

    Full Text Available The results of patients operated on by Nepal Cleft Lip and Palate Association (NECLAPA surgeons for congenital macrostomia were prospectively studied between January 2000 and December 2002. There were four males and three females with a median age of 10 years. Three had an associated branchial arch syndrome. In all patients an overlapping repair of orbicularis oris was done. Six patients had a straight line closure with excellent cosmetic results and one a Z-plasty with a more obvious scar. All had a normal appearing commissure. Overlapping orbicularis repair with straight line skin closure for this rare congenital anomaly is recommended.

  10. Structural Analysis of an Integrated Model of Short Straight Section, Service Module, Jumper Connection and Magnet Interconnects for the Large Hadron Collider

    CERN Document Server

    Dutta, S; Kumar, A; Skoczen, B; Soni, H C

    2004-01-01

    The Short Straight Section (SSS) of the Large Hadron Collider (LHC) may undergo relative displacements between cold-mass and cryostat for the following three reasons: - Fabrication tolerance of interconnection bellows - Global smoothing after pre-alignment - Ground motion in a sector of the LHC tunnel The forces responsible for such displacements stem from finite stiffness of interconnect bellows & metal hoses of the internal piping of the jumper connection and from relatively flexible 'glass fibre reinforced epoxy' (GFRE) composite supports of the cold mass. In addition, the vacuum jacket of the jumper connection and the large sleeves attached to both ends of SSS produce elastic deformations of the cryostat vessel. A unified finite element model consisting of cryostat, large sleeves, vacuum jacket of jumper, interconnection bellows, internal piping of jumper, composite cold supports and alignment jacks has been prepared. The knowledge of the position of the cold mass with respect to its cryostat under va...

  11. Highly sensitive straightness measurement system using a ball-lens

    International Nuclear Information System (INIS)

    Lee, Minho; Yang, Hyun-Ik; Cho, Nahm-Gyoo

    2016-01-01

    In this paper, a new and simple optical technique to accurately measure the straightness errors of a linear stage is proposed. To improve the performance, including the measurement sensitivity and resolution of the measurement system, and to simultaneously measure two-dimensional straightness errors (2D straightness errors), an optical system was designed using a laser, a retro-reflector, a ball-lens, and a two-dimensional position sensitive detector (2D PSD). The characteristics of the measurement system were analytically and experimentally investigated. A prototype measurement system was manufactured based on the investigated results, and the performances of this system have been tested. The measuring performance of the system was easily improved by about 12 times using the proposed technique and it can be further improved. It is shown that the proposed technique can easily and effectively improve the performance of a conventional straightness measurement system based on the geometric optical method using a PSD. (paper)

  12. Fatigue test results of straight pipe with flaws in inner surface

    International Nuclear Information System (INIS)

    Shibata, Katsuyuki; Oba, Toshihiro; Kawamura, Takaichi; Yokoyama, Norio; Miyazono, Shohachiro

    1981-01-01

    Fatigue and fracture tests of piping models with flaws in the inner surface were carried out to investigate the fatigue crack growth, coalescence of multiple cracks and fracture behavior. Two straight test pipes with and without weldment in the test section of SUS304L stainless steel were tested under almost the same test conditions. Three artificial defects were machined in the inner surface of the test section of the test pipes. The fatigue test were performed untill the cracks coalesced and grew through the thickness. Subsequently, a static load was imposed on test pipe which contained a large crack in the test section. The test results show that the fatigue crack growth is slower than that predicted by the method specified in the Section XI of ASME Boiler and Pressure Vessel Code, and that the test pipes can endure more than the static load of 3Sm without an unstable fracture. (author)

  13. Visualisation of flow patterns in straight and C-shape thermosyphons

    Science.gov (United States)

    Ong, K. S.; Tshai, K. H.; Firwana, A.

    2017-04-01

    A heat pipe is a passive heat transfer device capable of transferring a large quantity of heat effectively and efficiently over a long distance and with a small temperature difference between the heat source and heat sink. A heat pipe consists of a metal pipe initially vacuumed and then filled with a small quantity of fluid inside. The pipe is separated into a heating (evaporator) section and a cooling (condenser) section by an adiabatic section. In a run-around-coil heating, ventilation and air conditioning system, a wrap-around heat pipe heat exchanger could be employed to increase dehumidification and to reduce cooling costs. The thermal performance of a thermosyphon is dependent upon type of fill liquid, fill ratio, power input, pipe inclination and pipe dimensions. The boiling and condensation processes that occur inside a thermosyphon are quite complex. During operation, dry-out, burn-out or boiling limit, entrainment or flooding limit and geysering occur. These phenomena would lead to non-uniform axial wall temperature distribution in the pipe, or worse still, ineffective operation. In order to have a better understanding of the internal heat transfer phenomena, a visual study using transparent glass tubes and high speed camera recording of the internal flow patterns would be most helpful. This paper reports on an experimental investigation conducted to visualise the flow patterns in straight and C-shape thermosyphons. The pictures recorded enabled the internal flow boiling and condensation pattern occurring inside a straight and a C-shape thermosyphon to be observed. The thermosyphons were fabricated from 10 mm O/D × 8 mm I/D × 300 mm long glass tubes and filled with water with fill ratios from 0.5 - 1.5. The evaporator sections of the thermosyphons were immersed into a hot water tank that was electrically heated from cold at ambient temperature till boiling. Cooling of the condenser section was achieved using a fan. Preliminary results showed that dry

  14. Vacuum performance of a carbon fibre cryosorber for the LHC LSS beam screen

    CERN Document Server

    Anashin, V V; Dostovalov, R V; Korotaeva, Z A; Krasnov, A A; Malyshev, O B; Poluboyarov, V A

    2004-01-01

    A new carbon fibre material was developed at the Institute of Solid State Chemistry and Mechanochemistry at the Siberian Branch of the Russian Academy of Science (SB RAS) to meet the large hadron collider (LHC) vacuum chamber. The material must have a large sorbing capacity, a certain pumping speed, a working temperature range between 5 and 20K, a low activation temperature (below room temperature), a certain size in order to fit into the limited space available and it should be easy to mount. The vacuum parameters of the LHC vacuum chamber prototype with a carbon fibre cryosorber mounted onto the beam screen were studied in the beam screen temperature range from 14 to 25K at the Budker Institute of Nuclear Physics SB RAS. This carbon fibre material has shown sufficient sorption capacity for hydrogen at operational temperatures of the beam screen in the LHC long straight sections. It is also very important that this material does not crumble and makes a convenient fixation onto the beam screen in comparison t...

  15. Diffraction at a Straight Edge

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 20; Issue 5. Diffraction at a Straight Edge: A Gem from Sommerfeld's Work in Classical Physics. Rajaram Nityananda. General Article Volume 20 Issue 5 May 2015 pp 389-400 ...

  16. Head and pelvic movement asymmetry during lungeing in horses with symmetrical movement on the straight.

    Science.gov (United States)

    Rhodin, M; Roepstorff, L; French, A; Keegan, K G; Pfau, T; Egenvall, A

    2016-05-01

    Lungeing is commonly used as part of standard lameness examinations in horses. Knowledge of how lungeing influences motion symmetry in sound horses is needed. The aim of this study was to objectively evaluate the symmetry of vertical head and pelvic motion during lungeing in a large number of horses with symmetric motion during straight line evaluation. Cross-sectional prospective study. A pool of 201 riding horses, all functioning well and considered sound by their owners, were evaluated in trot on a straight line and during lungeing to the left and right. From this pool, horses with symmetric vertical head and pelvic movement during the straight line trot (n = 94) were retained for analysis. Vertical head and pelvic movements were measured with body mounted uniaxial accelerometers. Differences between vertical maximum and minimum head (HDmax, HDmin) and pelvic (PDmax, PDmin) heights between left and right forelimb and hindlimb stances were compared between straight line trot and lungeing in either direction. Vertical head and pelvic movements during lungeing were more asymmetric than during trot on a straight line. Common asymmetric patterns seen in the head were more upward movement during push-off of the outside forelimb and less downward movement during impact of the inside limb. Common asymmetric patterns seen in the pelvis were less upward movement during push-off of the outside hindlimb and less downward movement of the pelvis during impact of the inside hindlimb. Asymmetric patterns in one lunge direction were frequently not the same as in the opposite direction. Lungeing induces systematic asymmetries in vertical head and pelvic motion patterns in horses that may not be the same in both directions. These asymmetries may mask or mimic fore- or hindlimb lameness. © 2015 The Authors. Equine Veterinary Journal published by John Wiley & Sons Ltd on behalf of EVJ Ltd.

  17. A Modular Design for the 56 Variants of the Short Straight Section in the Arcs of the Large Hadron Collider (LHC)

    CERN Document Server

    Bergot, J B; Nielsen, L; Parma, Vittorio; Peyrot, M; Renaglia, T; Rifflet, J M; Rohmig, P; Roy, E; Simon, F; Tortschanoff, Theodor; Vincent, D

    2000-01-01

    The 360 Short Straight Sections (SSS) necessary for the eight arcs of the LHC machine have to fulfil different requirements. Their main function is to house the lattice two-in-one superconducting quadrupole and various correction magnets, all operating at 1.9 K in a superfluid helium bath. The magnetic and powering schemes of the arcs and the fact that the two proton beams alternate between the inner and outer magnet channels impose 24 different combinations of magnet assemblies, all housed in an identical helium enclosure. The cryogenic architecture of the LHC machine is based on cryogenic loops spanning over one half-cell (53 m) for the 4.6-20 K circuit, over a full cell (107 m) for the 1.9 K circuits, up to the full arc (about 2.3 km) for the shield cooling line. This cryogenic layout, when superimposed to the magnetic scheme, further complicated by the cryostat insulation vacuum sectorisation every 2 cells, creates additional assembly variants, up to a total number of 56. The required flexibility in the m...

  18. 49 CFR Appendix A to Part 1035 - Uniform Straight Bill of Lading

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 8 2010-10-01 2010-10-01 false Uniform Straight Bill of Lading A Appendix A to Part 1035 Transportation Other Regulations Relating to Transportation (Continued) SURFACE... Appendix A to Part 1035—Uniform Straight Bill of Lading Uniform Straight Bill of Lading Original—Not...

  19. Setting the Record Straight. The Truth About Fad Diets.

    Science.gov (United States)

    Wheat Foods Council, Parker, CO.

    The Setting the Record Straight information packet presents facts to set the record straight about nutrition and debunk fad diets. The kit features materials designed to communicate the importance of balanced eating. Materials include: a time line of fad diets; four reproducible fad diet book review handouts that show the misleading claims rampant…

  20. A modified straight leg raise test to differentiate between sural nerve pathology and Achilles tendinopathy. A cross-sectional cadaver study

    NARCIS (Netherlands)

    Coppieters, M.W.J.; Crooke, J.L.; Lawrenson, P.R.; Khoo, S.J.; Skulstad, T.; Bet-Or, Y.

    2015-01-01

    Background: A modified straight leg raise test for the sural nerve (SLRSURAL) has been proposed to assist in the differential diagnosis of sural nerve pathology in people with posterior calf or ankle pain, or lateral foot pain. The biomechanical rationale is that strain in the

  1. NuFact muon storage ring: study of a triangle design based on solenoid focusing decay straights

    Energy Technology Data Exchange (ETDEWEB)

    Meot, F. [Service Accelerateurs, Laboratoire de Physique Subatomique et de Cosmologie, Universite Joseph Fourier / CNRS-IN2P3, 53 Avenue des Martyrs, F-38026 Grenoble (France)]|[Commissariat a l' Energie Atomique, CEA, 31-33, rue de la Federation (Paris 15e), BP 510, 75752 Paris Cedex 15 (France); Reesy, G. [Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, Didcot OX11 0QX (United Kingdom)

    2006-06-15

    Properties of acceptance and beam transmission in a triangle design of the neutrino factory muon decay ring, with decay straights based on solenoidal focusing, are reported.The muon storage ring in the neutrino factory, NuFact, is located at the high energy end of the muon acceleration chain. It delivers the {mu}{sup +}/{mu}{sup -} decay neutrinos to physics detectors. The design of concern here, is a triangle geometry 20 GeV storage ring, upgradable to 50 GeV, (the parameters are given), which features two decay straight sections, each one aiming at a distant detector. The third straight section of the ring is devoted to tuning, collimation and RF. A particularity of the proposed design, is in its being based on solenoid focusing decay straights, which has the virtue of minimizing the betatron amplitudes, compared to equivalent quadrupole focusing. The solenoidal focusing ensures the requested ratio, for the r.m.s. divergences of the 20 GeV muon and the neutrino beam, of 0.1 for an assumed muon normalized r.m.s. emittance of 4800 {pi} mm mr (3 {pi} cm, total). The goal of the present work is to show the viability of this design, in particular as concerns the impact of the solenoid focusing on machine behavior. It addresses the questions of residual coupling, machine acceptance, and concludes with a computation of beam transmission over 1000 turns. The paper has the following structure: 1. Introduction; 2. Working hypothesis; 3. Building-up ray-tracing data; 3.1. Arcs; 3.2. Solenoid straight; 3.3. Tuning/Collimation/RF straight; 3.4. Full ring; 3.4.1. Beam envelopes; 3.4.2. Closed orbits; 3.4.3. Momentum dispersion; 3.5 Large amplitude tracking, preliminary tests; 4. Tracking, linear machine; 4.1. Large amplitude tracking; 4.1.1. 2-D horizontal initial conditions; 4.1.2. 2-D vertical initial conditions; 4.1.3. 4-D + {delta}p/p initial conditions; 4.2. Transmission, 4-D + {delta}p/p, no sextupoles; 4.2.1. {epsilon}{sub x} {epsilon}{sub z} = 3 {pi} cm (norm.), {delta

  2. NuFact muon storage ring: study of a triangle design based on solenoid focusing decay straights

    International Nuclear Information System (INIS)

    Meot, F.; Reesy, G.

    2006-06-01

    Properties of acceptance and beam transmission in a triangle design of the neutrino factory muon decay ring, with decay straights based on solenoidal focusing, are reported.The muon storage ring in the neutrino factory, NuFact, is located at the high energy end of the muon acceleration chain. It delivers the μ + /μ - decay neutrinos to physics detectors. The design of concern here, is a triangle geometry 20 GeV storage ring, upgradable to 50 GeV, (the parameters are given), which features two decay straight sections, each one aiming at a distant detector. The third straight section of the ring is devoted to tuning, collimation and RF. A particularity of the proposed design, is in its being based on solenoid focusing decay straights, which has the virtue of minimizing the betatron amplitudes, compared to equivalent quadrupole focusing. The solenoidal focusing ensures the requested ratio, for the r.m.s. divergences of the 20 GeV muon and the neutrino beam, of 0.1 for an assumed muon normalized r.m.s. emittance of 4800 π mm mr (3 π cm, total). The goal of the present work is to show the viability of this design, in particular as concerns the impact of the solenoid focusing on machine behavior. It addresses the questions of residual coupling, machine acceptance, and concludes with a computation of beam transmission over 1000 turns. The paper has the following structure: 1. Introduction; 2. Working hypothesis; 3. Building-up ray-tracing data; 3.1. Arcs; 3.2. Solenoid straight; 3.3. Tuning/Collimation/RF straight; 3.4. Full ring; 3.4.1. Beam envelopes; 3.4.2. Closed orbits; 3.4.3. Momentum dispersion; 3.5 Large amplitude tracking, preliminary tests; 4. Tracking, linear machine; 4.1. Large amplitude tracking; 4.1.1. 2-D horizontal initial conditions; 4.1.2. 2-D vertical initial conditions; 4.1.3. 4-D + δp/p initial conditions; 4.2. Transmission, 4-D + δp/p, no sextupoles; 4.2.1. ε x ε z = 3 π cm (norm.), δp/p = ±1%; 4.2.2. ε x ε z = 6 π cm (norm.), δp/p ±4

  3. Preferences of AP position of the straight Caucasian facial profile.

    Science.gov (United States)

    Mees, Steven; Jiménez Bellinga, Raúl; Mommaerts, Maurice Y; De Pauw, Guy A M

    2013-12-01

    Several investigators have compared the perception of profile attractiveness between professional and non-professional people, different groups of clinicians, and different ethnic groups. Our aim was to study preferences for facial protrusion in the lateral view for a straight Class I profile and to study the influence of gender, age, sex preference, and profession. Portrait images of one male and one female model with a Class I occlusal relationship were warped into nine different antero-posterior positions. An internet site was established to reach as many people as possible, and a request was sent by email to participate in a scientific experiment. Finally, 1707 Caucasion assessors could be grouped. The preferred male profile is the straight full ante profile. For a feminine facial profile, the straight average and the straight 2/3 ante profiles were perceived as the most attractive. Surgeons tended to give significantly higher scores to attractive (ante) profiles, which correlated strongly with scores of the orthodontists. Whenever possible with combined orthodontic/surgery treatment, straight ante profiles should be aimed for. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  4. submitter Influence of 3D Effects on Field Quality in the Straight Part of Accelerator Magnets for the High Luminosity Large Hadron Collider

    CERN Document Server

    Nilsson, Emelie; Todesco, Ezio; Enomoto, Shun; Farinon, Stefania; Fabbricatore, Pasquale; Nakamoto, Tatsushi; Sugano, Michinaka; Savary, Frederic

    2017-01-01

    A dedicated D1 beam separation dipole is currently being developed at KEK for the Large Hadron Collider Luminosity upgrade (HL-LHC). Four 150 mm aperture, 5.6 T magnetic field and 6.7 m long Nb-Ti magnets will replace resistive D1 dipoles. The development includes fabrication and testing of 2.2 m model magnets. The dipole has a single layer coil and thin spacers between coil and iron, giving a non-negligible impact of saturation on field quality at nominal field. The magnetic design of the straight section coil cross section is based on 2D optimization and a separate optimization concerns the coil ends. However, magnetic measurements of the short model showed a large difference (tens of units) between the sextupole harmonic in the straight part and the 2D calculation. This difference is correctly modelled only by a 3D analysis: 3D calculations show that the magnetic field quality in the straight part is influenced by the coil ends, even for the 6.7 m long magnets. The effect is even more remarkable in the sho...

  5. submitter Influence of 3D Effects on Field Quality in the Straight Part of Accelerator Magnets for the High Luminosity Large Hadron Collider

    CERN Document Server

    Nilsson, Emelie; Todesco, Ezio; Enomoto, Shun; Farinon, Stefania; Fabbricatore, Pasquale; Nakamoto, Tatsushi; Sugano, Michinaka; Savary, Frederic

    2018-01-01

    A dedicated D1 beam separation dipole is currently being developed at KEK for the Large Hadron Collider Luminosity upgrade (HL-LHC). Four 150 mm aperture, 5.6 T magnetic field and 6.7 m long Nb-Ti magnets will replace resistive D1 dipoles. The development includes fabrication and testing of 2.2 m model magnets. The dipole has a single layer coil and thin spacers between coil and iron, giving a non-negligible impact of saturation on field quality at nominal field. The magnetic design of the straight section coil cross section is based on 2D optimization and a separate optimization concerns the coil ends. However, magnetic measurements of the short model showed a large difference (tens of units) between the sextupole harmonic in the straight part and the 2D calculation. This difference is correctly modelled only by a 3D analysis: 3D calculations show that the magnetic field quality in the straight part is influenced by the coil ends, even for the 6.7 m long magnets. The effect is even more remarkable in the sho...

  6. Biomechanical differences in the stem straightening process among Pinus pinaster provenances. A new approach for early selection of stem straightness.

    Science.gov (United States)

    Sierra-de-Grado, Rosario; Pando, Valentín; Martínez-Zurimendi, Pablo; Peñalvo, Alejandro; Báscones, Esther; Moulia, Bruno

    2008-06-01

    Stem straightness is an important selection trait in Pinus pinaster Ait. breeding programs. Despite the stability of stem straightness rankings in provenance trials, the efficiency of breeding programs based on a quantitative index of stem straightness remains low. An alternative approach is to analyze biomechanical processes that underlie stem form. The rationale for this selection method is that genetic differences in the biomechanical processes that maintain stem straightness in young plants will continue to control stem form throughout the life of the tree. We analyzed the components contributing most to genetic differences among provenances in stem straightening processes by kinetic analysis and with a biomechanical model defining the interactions between the variables involved (Fournier's model). This framework was tested on three P. pinaster provenances differing in adult stem straightness and growth. One-year-old plants were tilted at 45 degrees, and individual stem positions and sizes were recorded weekly for 5 months. We measured the radial extension of reaction wood and the anatomical features of wood cells in serial stem cross sections. The integral effect of reaction wood on stem leaning was computed with Fournier's model. Responses driven by both primary and secondary growth were involved in the stem straightening process, but secondary-growth-driven responses accounted for most differences among provenances. Plants from the straight-stemmed provenance showed a greater capacity for stem straightening than plants from the sinuous provenances mainly because of (1) more efficient reaction wood (higher maturation strains) and (2) more pronounced secondary-growth-driven autotropic decurving. These two process-based traits are thus good candidates for early selection of stem straightness, but additional tests on a greater number of genotypes over a longer period are required.

  7. A new scheme for critical current measurements on straight superconducting cables in a large solenoid

    International Nuclear Information System (INIS)

    Rossi, L.; Volpini, G.

    1991-01-01

    The precision of I c measurement of straight superconducting cables in solenoids can be limited by the magnetic field inhomogeneity. A solution in order to improve the field homogeneity based on iron shims is presented here. A conceptual design for the experimental lay-out of a test station to be used in connection with the SOLEMI-I solenoid at the Milan INFN Section (LASA Laboratory) is given

  8. Stigma and Stigma by Association in Perceptions of Straight Allies

    Science.gov (United States)

    Goldstein, Susan B.

    2017-01-01

    As evidence builds for straight allies' contributions to battling sexual prejudice, barriers to assuming this role must be identified and dismantled. This study investigated stigma and stigma by association in perceptions of straight allies in a college population. Adjective rating items were completed by 505 participants who identified as…

  9. Spider diffraction: a comparison of curved and straight legs

    International Nuclear Information System (INIS)

    Richter, J.L.

    1984-01-01

    It has been known for some time that, if curved legs rather than the usual straight ones are used in the spider that supports the secondary optics in certain telescopes, the visible diffraction effect is reduced. Fraunhofer theory is used to calculate the diffraction effects due to the curved leg spider. Calculated and photographic diffraction patterns are compared for straight and curved leg spiders

  10. Classical and quantum chaos in a circular billiard with a straight cut

    International Nuclear Information System (INIS)

    Ree, S.; Reichl, L.E.

    1999-01-01

    We study classical and quantum dynamics of a particle in a circular billiard with a straight cut. Classically, this system can be integrable, nonintegrable with soft chaos, or nonintegrable with hard chaos as we vary the size of the cut. We plot Poincaracute e surfaces of section to study chaos. Quantum mechanically, we look at Husimi plots, and also use the quantum web, the technique primarily used in spin systems so far, to try to see differences in quantum manifestations of soft and hard chaos. copyright 1999 The American Physical Society

  11. Spherical Projection Based Straight Line Segment Extraction for Single Station Terrestrial Laser Point Cloud

    Directory of Open Access Journals (Sweden)

    ZHANG Fan

    2015-06-01

    Full Text Available Due to the discrete distribution computing errors and lack of adaptability are ubiquitous in the current straight line extraction for TLS data methods. A 3D straight line segment extraction method is proposed based on spherical projection for single station terrestrial laser point clouds. Firstly, horizontal and vertical angles of each laser point are calculated by means of spherical coordinates, intensity panoramic image according to the two angles is generated. Secondly, edges which include straight line features are detected from intensity panoramic image by using of edge detection algorithm. Thirdly, great circles are detected from edges of panoramic image using spherical Hough transform. According to the axiom that a straight line segment in 3D space is a spherical great circle after spherical projection, detecting great circles from spherical projected data sets is essentially detecting straight line segments from 3D data sets without spherical projection. Finally, a robust 3D straight line fitting method is employed to fitting the straight lines and calculating parameters of the straight line segments. Experiments using different data sets and comparison with other methods show the accuracy and applicability of the proposed method.

  12. Registration of airborne LiDAR data and aerial images based on straight lines and POS data

    Science.gov (United States)

    Du, Quanye; Xu, Biao; Cao, Hui

    2009-10-01

    This paper presents a registration method which based on straight lines primitive. Firstly, 2D straight lines are extracted from aerial images using Canny operator and straight line fitting. In the similar way, 3D straight lines are extracted from LiDAR range images which derive from laser scanning point cloud. Secondly, 3D straight lines are projected to aerial images using collinearity equations and Position and Orientation System (POS) data. Then the corresponding lines are determined by straight line error. At last, each image's new exterior orientation elements are calculated by generalized point (straight line) photogrammetry.

  13. Flow characteristics of developing laminar steady flows in a straight duct connected to a square curved duct

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Hyun Chull [Chosun Univ., Gwangju (Korea, Republic of)

    2005-05-01

    In the present study, the characteristics of developing steady laminar flows of a straight duct connected to a 180 .deg. curved duct were examined in the entrance region through experimental measurement. Flow characteristics such as shear stress distributions, pressure distributions and friction coefficient experimentally in a square cross-sectional straight duct by using the PIV system. For the PIV measurement by particles produced from mosquito coils particles. The experimental data were obtained at 9 points dividing the test sections by 400 mm. Experimental results can be summarized as follows. Critical Reynolds number, Re{sub cr} which indicates transition from laminar steady flow to transition steady flow was 2,150. Shear stress per unit length on the wall was stronger than that in the fully developed flow region. This was attributed to the fact that shear stress and pressure loss in the curvature of a duct were increased. Pressure distributions were gradually decreased irrespective of Reynolds number in the whole test section. This trends were in a good agreement with the reference results. Pipe friction coefficient in the steady state flow region was calculate from method of least squares. The co-relationship between fiction coefficient and Reynolds number was established as follow; {lambda}=56/Re.

  14. Body image in gay and straight men: a qualitative study.

    Science.gov (United States)

    Morgan, John F; Arcelus, Jon

    2009-11-01

    Recent research has emphasized vulnerability to eating disorders in gay men, with calls for research on causality, cultural factors and focus on a younger age cohort. This study aimed to examine body image and related eating behaviours in younger gay and straight men. Qualitative study using a sample of gay and straight male university students, applying audiotaped and transcribed depth interview subjected to interpretative phenomenological analysis. Fifteen young men (18-24) with a spectrum of sexual orientation (gay, straight and bisexual) agreed to participate. Five dominant categories emerged: body image ideal, external influences, perception of body image, dieting, mechanisms for modification (diet, exercise, cosmetics) and sexual orientation. Health and aesthetic ideals appear less divorced for young men than women, offering some degree of protection from eating disorders. Nonetheless there is widespread body dissatisfaction. Media and social influences are powerful, particularly for single gay men, but the study suggests fewer differences than similarities between gay and straight men. Copyright (c) 2009 John Wiley & Sons, Ltd and Eating Disorders Association.

  15. A laser interferometer for measuring straightness and its position based on heterodyne interferometry

    International Nuclear Information System (INIS)

    Chen Benyong; Zhang Enzheng; Yan Liping; Li Chaorong; Tang Wuhua; Feng Qibo

    2009-01-01

    Not only the magnitude but also the position of straightness errors are of concern to users. However, current laser interferometers used for measuring straightness seldom give the relative position of the straightness error. To solve this problem, a laser interferometer for measuring straightness and its position based on heterodyne interferometry is proposed. The optical configuration of the interferometer is designed and the measurement principle is analyzed theoretically. Two experiments were carried out. The first experiment verifies the validity and repeatability of the interferometer by measuring a linear stage. Also, the second one for measuring a flexure-hinge stage demonstrates that the interferometer is capable of nanometer measurement accuracy. These results show that this interferometer has advantages of simultaneously measuring straightness error and the relative position with high precision, and a compact structure.

  16. Straight and Curved Path Walking Among Older Adults in Primary Care: Associations With Fall-Related Outcomes.

    Science.gov (United States)

    Welch, Sarah A; Ward, Rachel E; Kurlinski, Laura A; Kiely, Dan K; Goldstein, Richard; VanSwearingen, Jessie; Brach, Jennifer S; Bean, Jonathan F

    2016-08-01

    Most falls among community-dwelling older adults occur while walking. Simple walking tests that require little resources and can be interpreted quickly are advocated as useful screening tools for fall prone patients. To investigate 2 clinically feasible walking tests consisting of straight- and curved-path walking and examine their associations with history of previous falls and fall-related outcomes among community-living older adults. A cross-sectional analysis was performed on baseline data from a longitudinal cohort study. Participants were recruited through primary care practices. Participants included 428 primary care patients ≥65 years of age at risk for mobility decline. Participants had a median age of 76.5 years, 67.8% were women, and 82.5% were white. Straight-path walking performance was measured as the time needed to walk a 4-meter straight path at usual pace from standstill using a stopwatch (timed to 0.1 second). Curved-path walking performance was timed while participants walked from standstill in a figure-of-8 pattern around two cones placed 5 feet apart. Multivariable negative binomial regression analyses were performed to assess the relationship between straight-path walking or curved-path walking and self-reported history of number of falls. For fall-related injuries, and fall-related hospitalizations, logistic regression models were used. In the fully adjusted model, an increase of 1 second in straight path walking time was associated with 26% greater rate of falls (rate ratio 1.26, 95% confidence interval 1.10-1.45). An increase in curved-path walking time was associated with 8% greater rate of falls (rate ratio 1.08, 95% confidence interval = 1.03-1.14). Neither walk test was associated with history of fall-related injuries or hospitalizations. Poor performance on straight- and curved-path walking performance was associated with a history of greater fall rates in the previous year but not with a history of fall-related injuries or

  17. Straight, white teeth as a social prerogative.

    Science.gov (United States)

    Khalid, Abeer; Quiñonez, Carlos

    2015-06-01

    A distinguishing feature of North American society is preoccupation with self-image, as seen in the ritualistic nature of bodily practices aimed at constantly improving the body. Nowhere is this more apparent than in the prevailing fixation with straight, white teeth. While there is an ever-expanding literature on the sociology of body, very little has been written on teeth in this context. Using literature from anthropology, biology, dentistry, sociology and social psychology, this study attempts to answer: (1) Why have straight, white teeth become a beauty ideal in North American society? (2) What is the basis for this ideal? (3) How is this ideal propagated? It demonstrates that dental aesthetic tendencies are biologically, culturally and socially patterned. Concepts from the works of Pierre Bourdieu and Michel Foucault are used to illustrate how straight, white teeth contribute towards reinforcing class differences and how society exercises a disciplinary power on individuals through this ideal. It is concluded that modified teeth are linked to self and identity that are rooted in social structure. Moreover, teeth demonstrate the ways in which class differences are embodied and projected as symbols of social advantage or disadvantage. Implications on professional, public health, sociological and political levels are considered. © 2015 Foundation for the Sociology of Health & Illness.

  18. Net-section limit moments and approximate J estimates for circumferential cracks at the interface between elbows and pipes

    International Nuclear Information System (INIS)

    Song, Tae-Kwang; Kim, Yun-Jae; Oh, Chang-Kyun; Jin, Tae-Eun; Kim, Jong-Sung

    2009-01-01

    This paper firstly presents net-section limit moments for circumferential through-wall and part-through surface cracks at the interface between elbows and attached straight pipes under in-plane bending. Closed-form solutions are proposed based on fitting results from small strain FE limit analyses using elastic-perfectly plastic materials. Net-section limit moments for circumferential cracks at the interface between elbows and attached straight pipes are found to be close to those for cracks in the centre of elbows, implying that the location of the circumferential crack within an elbow has a minimal effect on the net-section limit moment. Accordingly it is also found that the assumption that the crack locates in a straight pipe could significantly overestimate the net-section limit load (and thus maximum load-carrying capacity) of the cracked component. Based on the proposed net-section limit moment, a method to estimate elastic-plastic J based on the reference stress approach is proposed for circumferential cracks at the interface between elbows and attached straight pipes under in-plane bending.

  19. Straight configuration saphenous vein transposition to popliteal artery for vascular access.

    Science.gov (United States)

    Caco, Gentian; Golemi, Dhurata; Likaj, Eriola

    2017-03-21

    The saphenous vein is commonly used as a vascular graft in peripheral artery surgery but rarely used for vascular access. The literature on straight configuration saphenous vein transposition to the popliteal artery is scarce. Here we present two cases of straight configuration saphenous vein transposition to the popliteal artery for vascular access, the surgical technique and respective follow-up. Two young men, aged 29 and 36 years, were chosen for lower-limb vascular access for hemodialysis. The first patient was paraplegic since birth. He used his arms to move so upper extremity vascular access was avoided. The second patient presented with an infected upper extremity arteriovenous graft (AVG) and after multiple closed AVFs he had no more available arm veins. Both patients received autologous lower extremity straight configuration saphenous vein transpositions to the popliteal artery under spinal anesthesia in May and October 2012, respectively. Cannulation of the fistula was allowed after one month. There were no early complications. Slight swelling on the leg appeared in one of the patients. Both fistulas were still functional after 36 and 32 months, respectively. The straight configuration saphenous vein transposition to popliteal artery is simple to perform, offers a long and straight segment for cannulation and may be a suitable autologous vascular access in selected patients.

  20. Qingping Straight Sword: The Last Remaining Chinese Sword System?

    Directory of Open Access Journals (Sweden)

    Stephan Berwick

    2012-07-01

    Full Text Available The following examination of classical Chinese straight sword (jian details the very rare Qingping straight sword system. The study meshes Chinese- and English-sourced research with a revealing interview (conducted by America’s senior Qingping disciples, Reza Momenan and Hon Lee with Lu Junhai—the grandmaster of this unique sword system. The author presents Qingping system as perhaps the only known, complete Chinese sword system surviving from China’s pre-Rebulican era (1911-1949.

  1. A mathematical model for camera calibration based on straight lines

    Directory of Open Access Journals (Sweden)

    Antonio M. G. Tommaselli

    2005-12-01

    Full Text Available In other to facilitate the automation of camera calibration process, a mathematical model using straight lines was developed, which is based on the equivalent planes mathematical model. Parameter estimation of the developed model is achieved by the Least Squares Method with Conditions and Observations. The same method of adjustment was used to implement camera calibration with bundles, which is based on points. Experiments using simulated and real data have shown that the developed model based on straight lines gives results comparable to the conventional method with points. Details concerning the mathematical development of the model and experiments with simulated and real data will be presented and the results with both methods of camera calibration, with straight lines and with points, will be compared.

  2. Cherry Picking: Virginity Loss Definitions Among Gay and Straight Cisgender Men.

    Science.gov (United States)

    Huang, Howard

    2017-08-03

    Virginity loss is a vital milestone in the development of one's sexual identity. Unfortunately, there is very little literature available studying virginity loss definitions among the wider straight population, and even less examining virginity loss among LGBTQ+ populations. The present study recruited 251 (45.4%) cisgender straight men and 114 (54.6%) cisgender gay men. An online, anonymous survey was administered to explore whether they considered various male-on-male (M-M) and male-on-female (M-F) sexual behaviors as constitutive of virginity loss. Results indicate that more gay men than straight considered M-M receptive anal intercourse (i.e., bottoming) and M-F penetrative anal intercourse to be constitutive of virginity loss. Results also indicate that both gay and straight men almost unanimously endorsed M-F penovaginal sex to be constitutive of virginity loss. This study is a first-step toward gaining a better understanding of LGBTQ+ virginity loss conceptualizations. Future research is strongly encouraged.

  3. Straight vegetable oils usage in a compression ignition engine - A review

    Energy Technology Data Exchange (ETDEWEB)

    Misra, R.D.; Murthy, M.S. [Mechanical Engineering Department, National Institute of Technology, Silchar 788010, Assam (India)

    2010-12-15

    The ever increasing fossil fuel usage and cost, environmental concern has forced the world to look for alternatives. Straight vegetable oils in compression ignition engine are a ready solution available, however, with certain limitations and with some advantages as reported by many researchers. A comprehensive and critical review is presented specifically pertaining to straight vegetable oils usage in diesel engine. A detailed record of historical events described. Research carried out specifically under Indian conditions and international research work on the usage of straight vegetable oils in the diesel engine is separately reviewed. Many researchers have reported that straight vegetable oils in small percentage blends with diesel when used lower capacity diesel engines have shown great promise with regards to the thermal performance as well exhaust emissions. This has been explained in detail. Finally based on the review of international as well as Indian research a SWOT analysis is carried out. The review concludes that there is still scope for research in this area. (author)

  4. Design rules for piping: Plastic stability of straight parts under level D loadings

    International Nuclear Information System (INIS)

    Touboul, F.; Ben Djidia, M.; Acker, D.

    1989-01-01

    Design rules for piping, elaborated for Fast Breeder Reactors, are based on analysis performed for Pressure Water Reactors. Interpretation of largely diversified straight parts tests, enable us to validate and improve existing rules and to propose a more suitable formula. Design rules for piping appear to be non conservative for austenitic thin tubes in bending or torsion. By introducing a B 2 coefficient, geometrically dependent, the gap between thin and thick tubes may be withheld. Conservatism of rules can be ensured by considering the allowable stress defined by ASME, Section III, Appendix F

  5. Lumbar Spinal Stenosis Has a Negative Impact on Quality of Life Compared with Other Comorbidities: An Epidemiological Cross-Sectional Study of 1862 Community-Dwelling Individuals

    Directory of Open Access Journals (Sweden)

    Koji Otani

    2013-01-01

    Full Text Available Lumbar spinal stenosis (LSS is common in the elderly. However, there have been few reports on its impact on quality of life (QoL in community-dwelling individuals. The purpose of this study was to clarify how symptomatic LSS affects QoL at the community level. A total of 1862 people (697 males and 1165 females, most subjects were between 40 and 85 y.o. agreed to participate and were interviewed. The presence of symptomatic LSS was assessed by a specially designed questionnaire. The Medical Outcomes Study 36-Item Short Form Health Survey (SF-36 was also administered. In addition, the presence of comorbid conditions that affect QoL, such as osteoarthritis of the knee and hip, cardiovascular disease, cerebrovascular disease, or respiratory disease, was also analyzed. The prevalence of symptomatic LSS gradually increased with age. Furthermore, the presence of symptomatic LSS had a strong negative effect on all 8 physical and mental domains and the physical component summary (PCS (OR: 1.547–2.544 but not the mental component summary (MCS. In comparison with comorbid conditions, LSS had a much stronger negative impact on health-related QoL (HR-QoL. The current study confirmed that the presence of symptomatic LSS might have a strong negative influence on HR-QoL in the community setting.

  6. Comparison of 21G curved and straight phacotips designs in transversal microcoaxial phacoemulsification

    Directory of Open Access Journals (Sweden)

    Süleyman Demircan

    2015-12-01

    Full Text Available AIM:To compare the intraoperative performance and postoperative outcomes after microcoaxial torsional phacoemulsification using the straight and the curved phacotip configurations.METHODS:Cataracts were treated using 2.2mm microcoaxial transversal phacoemulsification with either a 30°straight or 30° curved phaco tip. Intraoperative measurements analyzed included the average ultrasound(U/Spower, the total phacoemulsification time, and the effective phacoemulsification time(EPT. The central endothelial cell density(ECDand the central corneal thickness(CCTwere evaluated preoperatively and postoperatively at 1, 7 and 30d after surgery using noncontact specular microscopy. RESULTS:The study enrolled a total of 190 eyes(190 patients, 95 eyes in the curved tip group and 95 eyes in straight tip group. Intraoperative measurements showed significantly reduced total phacoemulsification time, and EPT in the curved-tip group, compared to the straight-tip group(Pst-3rd quartilesand 18.0(9.0-30.0s in curved-tip group, and 38.8(16.5-73.5s and 26.0(11.0-49.0s in the straight-tip group, respectively. CONCLUSION:Transversal phacoemulsification performed with a curved tip provided more effective lens removal with a less total UST and EPT in all grades, except for grades IV, compared to a straight tip.

  7. An intersection graph of straight lines

    DEFF Research Database (Denmark)

    Thomassen, Carsten

    2002-01-01

    G. Ehrlich, S. Even, and R.E. Tarjan conjectured that the graph obtained from a complete 3 partite graph K4,4,4 by deleting the edges of four disjoint triangles is not the intersection graph of straight line segments in the plane. We show that it is....

  8. Straight-line string with curvature

    International Nuclear Information System (INIS)

    Solov'ev, L.D.

    1995-01-01

    Classical and quantum solutions for the relativistic straight-line string with arbitrary dependence on the world surface curvature are obtained. They differ from the case of the usual Nambu-Goto interaction by the behaviour of the Regge trajectory which in general can be non-linear. A regularization of the action is considered and a comparison with relativistic point with curvature is made. 5 refs

  9. Gender, health behavior, and intimate relationships: lesbian, gay, and straight contexts.

    Science.gov (United States)

    Reczek, Corinne; Umberson, Debra

    2012-06-01

    Many studies focus on health behavior within the context of intimate ties. However, this literature is limited by reliance on gender socialization theory and a focus on straight (i.e., heterosexual) marriage. We extend this work with an analysis of relationship dynamics around health behavior in 20 long-term straight marriages as well as 15 gay and 15 lesbian long-term cohabiting partnerships in the United States (N = 100 individual in-depth interviews). We develop the concept of "health behavior work" to align activities done to promote health behavior with theories on unpaid work in the home. Respondents in all couple types describe specialized health behavior work, wherein one partner works to shape the other partner's health behavior. In straight couples, women perform the bulk of specialized health behavior work. Most gay and lesbian respondents-but few straight respondents--also describe cooperative health behavior work, wherein partners mutually influence one another's health behaviors. Findings suggest that the gendered relational context of an intimate partnership shapes the dynamics of and explanations for health behavior work. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Intubation of prehospital patients with curved laryngoscope blade is more successful than with straight blade.

    Science.gov (United States)

    Alter, Scott M; Haim, Eithan D; Sullivan, Alex H; Clayton, Lisa M

    2018-02-17

    Direct laryngoscopy can be performed using curved or straight blades, and providers usually choose the blade they are most comfortable with. However, curved blades are anecdotally thought of as easier to use than straight blades. We seek to compare intubation success rates of paramedics using curved versus straight blades. Design: retrospective chart review. hospital-based suburban ALS service with 20,000 annual calls. prehospital patients with any direct laryngoscopy intubation attempt over almost 9years. First attempt and overall success rates were calculated for attempts with curved and straight blades. Differences between the groups were calculated. 2299 patients were intubated by direct laryngoscopy. 1865 had attempts with a curved blade, 367 had attempts with a straight blade, and 67 had attempts with both. Baseline characteristics were similar between groups. First attempt success was 86% with a curved blade and 73% with a straight blade: a difference of 13% (95% CI: 9-17). Overall success was 96% with a curved blade and 81% with a straight blade: a difference of 15% (95% CI: 12-18). There was an average of 1.11 intubation attempts per patient with a curved blade and 1.13 attempts per patient with a straight blade (2% difference, 95% CI: -3-7). Our study found a significant difference in intubation success rates between laryngoscope blade types. Curved blades had higher first attempt and overall success rates when compared to straight blades. Paramedics should consider selecting a curved blade as their tool of choice to potentially improve intubation success. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Transmission of fast highly charged ions through straight and tapered glass capillaries

    International Nuclear Information System (INIS)

    Ayyad, Asma M; Keerthisinghe, D; Kayani, A; Tanis, J A; Dassanayake, B S; Ikeda, T

    2013-01-01

    The transmission of 1 and 3 MeV protons through a borosilicate straight glass capillary and a tapered glass capillary was investigated. The straight capillary had a diameter of ∼0.18 mm and a length of ∼14.4 mm, while the tapered capillary had an inlet diameter of ∼0.71 mm, an outlet diameter of ∼0.10 mm and a length of ∼28 mm. The results show that the 1 and 3 MeV protons traverse through both samples without energy loss, while the tapered capillary showed better transmission than the straight capillary. (paper)

  12. Effect of iron catalyst thickness on vertically aligned carbon nanotube forest straightness for CNT-MEMS

    International Nuclear Information System (INIS)

    Moulton, Kellen; Jensen, Brian D; Morrill, Nicholas B; Konneker, Adam M; Vanfleet, Richard R; Allred, David D; Davis, Robert C

    2012-01-01

    This paper examines the effect of iron catalyst thickness on the straightness of growth of carbon nanotubes (CNTs) for microelectromechanical systems fabricated using the CNT-templated-microfabrication (CNT-M) process. SEM images of samples grown using various iron catalyst thicknesses show that both straight sidewalls and good edge definition are achieved using an iron thickness between 7 and 8 nm. Below this thickness, individual CNTs are well aligned, but the sidewalls of CNT forests formed into posts and long walls are not always straight. Above this thickness, the CNT forest sidewalls are relatively straight, but edge definition is poor, with significantly increased sidewall roughness. The proximity of a device or feature to other regions of iron catalyst also affects CNT growth. By using an iron catalyst thickness appropriate for straight growth, and by adding borders of iron around features or devices, a designer can greatly improve straightness of growth for CNT-MEMS. (paper)

  13. Computational Stud of Flow in Curved Pipes with Circular-Section

    OpenAIRE

    Shirayama, Susumu; Kawamura, Tetsuya; Kuwahara, Kunio; 白山, 晋; 河村, 哲也; 桑原, 邦郎

    1985-01-01

    By solving the incompressible Navier-Stokes equations the flow field is calculated in a circular-sectioned pipe with a straight inlet or gradually enlarged inlet in the higher Dean number. With the straight inlet, a secondary flow of cross-stream planes was obtained and with the higher Dean number some different flow patterns were obtained. With the gradually enlarged inlet, the difference of flow patterns corresponding to Reynolds number could be simulated.

  14. Effects of cavity on leakage loss in straight-through labyrinth seals

    International Nuclear Information System (INIS)

    Zhao, W; Nielsen, T K; Billdal, J T

    2010-01-01

    Labyrinth seals are widely used in rotating fluid machinery, due to its low-cost, simplicity and reliability. A straight-through labyrinth seal consists of a clearance between the stator and rotor, and sometimes cavities which are included on the stator or the rotator side. In this type of seals, making cavities are an effective way to convert turbulence kinetic energy into thermal energy by forming turbulence vortices, thereby reducing pressure difference and leakage flow. In this paper, the effect of cavities on leakage loss in straight-through labyrinth seals are studied by changing cavity dimensions such as depth and length, cavity number and cavity location. The influences of unilateral cavities and bilateral cavities on the leakage loss in straight-through labyrinth seals are also compared. The fluid flow characteristics through straight-through labyrinth seals were obtained by using viscous flow analysis along with a standard k-ωturbulence model. The cavity dimensions and cavity numbers have significant effects on the leakage as well as on the flow pattern in the seal. The bilateral cavity has better leakage performance than the unilateral cavity when cavity dimensions are identical. However, the cavity location shows no significant influences on the leakage flow.

  15. Implanting straight into cochlea risks the facial nerve: a Cartesian coordinate study.

    Science.gov (United States)

    Deshpande, Anita S; Wendell Todd, N

    2016-12-01

    To describe the straight-into-cochlea line that affords the best access for an electrode array to enter via the round window, and how this line relates to the facial nerve, the incus, and mastoid size. The straight-into-cochlea line is important to minimize the cochlear trauma and maximize the likelihood of placement into the scala tympani. High-resolution CT scans were obtained for ten craniums with the extremes of large (N = 5) and small (N = 5) mastoid pneumatization; the specimens were from a series of 41 ear normal craniums. Using FIJI, a publicly available software program, the straight-into-cochlea insertion line was determined by defining the x-y-z coordinates of the middle of the round window and a point 6.0 mm into the cochlea on its centrifugal wall. Then, from the extended straight-into-cochlea insertion line, we determined the shortest perpendicular distance to the middle of the fallopian canal, and from that "fallopian point" to the apex of the posterior process of the incus. We found good repeatability of measurements. We found the extended straight-into-cochlea insertion lines routinely close to or in the midst of the fallopian canal (50 % ≤ 1.0 mm). We found the lines 4.7-7.8 mm from the apex of the posterior process of the incus. Line positions relative to "fallopian point" and incus showed no relation to mastoid pneumatization. For the distance "fallopian point" to incus, bilateral symmetry was suggested. Using landmarks registered in an x-y-z coordinate system, straight-into-cochlea insertion via the round window puts the facial nerve at risk.

  16. Observational signatures of past mass-exchange episodes in massive binaries: the case of LSS 3074

    Science.gov (United States)

    Raucq, F.; Gosset, E.; Rauw, G.; Manfroid, J.; Mahy, L.; Mennekens, N.; Vanbeveren, D.

    2017-05-01

    Context. The role of mass and momentum exchanges in close massive binaries is very important in the subsequent evolution of the components. Such exchanges produce several observational signatures such as asynchronous rotation and altered chemical compositions, that remain after the stars detach again. Aims: We investigated these effects for the close O-star binary LSS 3074 (O4 f + O6-7:(f):), which is a good candidate for a past Roche lobe overflow (RLOF) episode because of its very short orbital period, P = 2.185 days, and the luminosity classes of both components. Methods: We determined a new orbital solution for the system. We studied the photometric light curves to determine the inclination of the orbit and Roche lobe filling factors of both stars. Using phase-resolved spectroscopy, we performed the disentangling of the optical spectra of the two stars. We then analysed the reconstructed primary and secondary spectra with the CMFGEN model atmosphere code to determine stellar parameters, such as the effective temperatures and surface gravities, and to constrain the chemical composition of the components. Results: We confirm the apparent low stellar masses and radii reported in previous studies. We also find a strong overabundance in nitrogen and a strong carbon and oxygen depletion in both primary and secondary atmospheres, together with a strong enrichment in helium of the primary star. Conclusions: We propose several possible evolutionary pathways through a RLOF process to explain the current parameters of the system. We confirm that the system is apparently in overcontact configuration and has lost a significant portion of its mass to its surroundings. We suggest that some of the discrepancies between the spectroscopic and photometric properties of LSS 3074 could stem from the impact of a strong radiation pressure of the primary. Based on observations collected at the European Southern Observatory (La Silla, Chile) and the Cerro Tololo Inter

  17. The appearance potency of gay and straight men’s websites

    OpenAIRE

    Jankowski, G.; Slater, A.; Tiggemann, M.; Fawkner, H.

    2016-01-01

    Gay men's greater body dissatisfaction compared to straight men has been explained as a result of gay men’s more 'appearance potent' subculture. This study aimed to critically appraise this explanation by assessing images of men and women for their physical characteristics and objectification across 8 popular gay and straight men's dating and porn websites. 1,415 images of men and 715 images of women across the website’s main pages were coded. Results showed that the gay men's websites featur...

  18. A simple algorithm for computing positively weighted straight skeletons of monotone polygons☆

    Science.gov (United States)

    Biedl, Therese; Held, Martin; Huber, Stefan; Kaaser, Dominik; Palfrader, Peter

    2015-01-01

    We study the characteristics of straight skeletons of monotone polygonal chains and use them to devise an algorithm for computing positively weighted straight skeletons of monotone polygons. Our algorithm runs in O(nlog⁡n) time and O(n) space, where n denotes the number of vertices of the polygon. PMID:25648376

  19. A simple algorithm for computing positively weighted straight skeletons of monotone polygons.

    Science.gov (United States)

    Biedl, Therese; Held, Martin; Huber, Stefan; Kaaser, Dominik; Palfrader, Peter

    2015-02-01

    We study the characteristics of straight skeletons of monotone polygonal chains and use them to devise an algorithm for computing positively weighted straight skeletons of monotone polygons. Our algorithm runs in [Formula: see text] time and [Formula: see text] space, where n denotes the number of vertices of the polygon.

  20. 26 CFR 7.57(d)-1 - Election with respect to straight line recovery of intangibles.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 14 2010-04-01 2010-04-01 false Election with respect to straight line recovery... ACT OF 1976 § 7.57(d)-1 Election with respect to straight line recovery of intangibles. (a) Purpose... Tax Reform Act of 1976. Under this election taxpayers may use cost depletion to compute straight line...

  1. Straight-Line Target Tracking for Unmanned Surface Vehicles

    Directory of Open Access Journals (Sweden)

    Morten Breivik

    2008-10-01

    Full Text Available This paper considers the subject of straight-line target tracking for unmanned surface vehicles (USVs. Target-tracking represents motion control scenarios where no information about the target behavior is known in advance, i.e., the path that the target traverses is not defined apriori. Specifically, this work presents the design of a motion control system which enables an underactuated USV to track a target that moves in a straight line at high speed. The motion control system employs a guidance principle originally developed for interceptor missiles, as well as a novel velocity controller inspired by maneuverability and agility concepts found in fighter aircraft literature. The performance of the suggested design is illustrated through full-scale USV experiments in the Trondheimsfjord.

  2. Lateral convection and diffusion of sediment in straight rivers

    DEFF Research Database (Denmark)

    Christensen, Henrik Bo; Fredsøe, Jørgen

    1998-01-01

    and a higher level of turbulence at the channel centre, than in the near bank zones, which means that the ability to support suspended sediment will decrease from the channel centre. The two turbulence models give different estimates for the lateral transport, which mainly are caused by turbulence generated......The lateral transport of suspended sediment in a straight river cross section with a parabolic shaped bed is studied be use of a k-e and a full Reynolds stress turbulence model. Due to depth variations a lateral transport of suspended sediment is generated. This is mainly caused by the slopping bed...... secondary flow cells in the Reynolds stress model. The flow cells make zones with alternately high and low sediment concentration, and thereby much higher local gradients in the lateral direction. Both models found a net inward lateral transport. The transport by convection was found more dominant than...

  3. SDSS-IV MaNGA: environmental dependence of stellar age and metallicity gradients in nearby galaxies

    Science.gov (United States)

    Zheng, Zheng; Wang, Huiyuan; Ge, Junqiang; Mao, Shude; Li, Cheng; Li, Ran; Mo, Houjun; Goddard, Daniel; Bundy, Kevin; Li, Hongyu; Nair, Preethi; Lin, Lihwai; Long, R. J.; Riffel, Rogério; Thomas, Daniel; Masters, Karen; Bizyaev, Dmitry; Brownstein, Joel R.; Zhang, Kai; Law, David R.; Drory, Niv; Roman Lopes, Alexandre; Malanushenko, Olena

    2017-03-01

    We present a study on the stellar age and metallicity distributions for 1105 galaxies using the STARLIGHT software on MaNGA (Mapping Nearby Galaxies at APO) integral field spectra. We derive age and metallicity gradients by fitting straight lines to the radial profiles, and explore their correlations with total stellar mass M*, NUV - r colour and environments, as identified by both the large-scale structure (LSS) type and the local density. We find that the mean age and metallicity gradients are close to zero but slightly negative, which is consistent with the inside-out formation scenario. Within our sample, we find that both the age and metallicity gradients show weak or no correlation with either the LSS type or local density environment. In addition, we also study the environmental dependence of age and metallicity values at the effective radii. The age and metallicity values are highly correlated with M* and NUV - r and are also dependent on LSS type as well as local density. Low-mass galaxies tend to be younger and have lower metallicity in low-density environments while high-mass galaxies are less affected by environment.

  4. Neck Muscle Moment Arms Obtained In-Vivo from MRI: Effect of Curved and Straight Modeled Paths.

    Science.gov (United States)

    Suderman, Bethany L; Vasavada, Anita N

    2017-08-01

    Musculoskeletal models of the cervical spine commonly represent neck muscles with straight paths. However, straight lines do not best represent the natural curvature of muscle paths in the neck, because the paths are constrained by bone and soft tissue. The purpose of this study was to estimate moment arms of curved and straight neck muscle paths using different moment arm calculation methods: tendon excursion, geometric, and effective torque. Curved and straight muscle paths were defined for two subject-specific cervical spine models derived from in vivo magnetic resonance images (MRI). Modeling neck muscle paths with curvature provides significantly different moment arm estimates than straight paths for 10 of 15 neck muscles (p straight lines to model muscle paths can lead to overestimating neck extension moment. However, moment arm methods for curved paths should be investigated further, as different methods of calculating moment arm can provide different estimates.

  5. Distorted eikonal cross sections: A time-dependent view

    International Nuclear Information System (INIS)

    Turner, R.E.

    1982-01-01

    For Hamiltonians with two potentials, differential cross sections are written as time-correlation functions of reference and distorted transition operators. Distorted eikonal differential cross sections are defined in terms of straight-line and reference classical trajectories. Both elastic and inelastic results are obtained. Expressions for the inelastic cross sections are presented in terms of time-ordered cosine and sine memory functions through the use of the Zwanzig-Feshbach projection-operator method

  6. A generalized, periodic nonlinearity-reduced interferometer for straightness measurements

    International Nuclear Information System (INIS)

    Wu Chienming

    2008-01-01

    Periodic nonlinearity is a systematic error limiting the accuracy of displacement measurements at the nanometer level. However, an interferometer with a displacement measurement accuracy of less than 1 nm is required in nanometrology and in fundamental scientific research. To meet this requirement, a generalized, periodic nonlinearity-reduced interferometer, based on three construction principles has been developed for straightness measurements. These three construction principles have resulted in an interferometer with a highly stable design with reduced periodic nonlinearity. Verifications by a straightness interferometer have demonstrated that the periodic nonlinearity was less than 40 pm. The results also demonstrate that the interferometer design is capable of subnanometer accuracy and is useful in nanometrology

  7. Friends with benefits, but without the sex: straight women and gay men exchange trustworthy mating advice.

    Science.gov (United States)

    Russell, Eric M; DelPriore, Danielle J; Butterfield, Max E; Hill, Sarah E

    2013-02-09

    Although research has made progress in elucidating the benefits exchanged within same- and opposite-sex friendships formed between heterosexual men and women, it is less clear why straight women and gay men form close relationships with one another. The current experiments begin to address this question by exploring a potential benefit hypothesized to be uniquely available to straight women and gay men in the context of these friendships: trustworthy mating advice. Experiment 1 revealed that straight women perceive mating-relevant advice from a gay man to be more trustworthy than similar advice offered by a straight man or woman. Experiment 2 demonstrated that gay men perceive mating advice offered by a straight woman to be more trustworthy than advice offered by a lesbian woman or another gay man. Overall, the results provide initial experimental evidence that relationships between gay men and straight women may be characterized by a mutual exchange of mating-relevant benefits in the absence of sexual interest or competition.

  8. Friends with Benefits, but without the Sex: Straight Women and Gay Men Exchange Trustworthy Mating Advice

    Directory of Open Access Journals (Sweden)

    Eric M. Russell

    2013-01-01

    Full Text Available Although research has made progress in elucidating the benefits exchanged within same- and opposite-sex friendships formed between heterosexual men and women, it is less clear why straight women and gay men form close relationships with one another. The current experiments begin to address this question by exploring a potential benefit hypothesized to be uniquely available to straight women and gay men in the context of these friendships: trustworthy mating advice. Experiment 1 revealed that straight women perceive mating-relevant advice from a gay man to be more trustworthy than similar advice offered by a straight man or woman. Experiment 2 demonstrated that gay men perceive mating advice offered by a straight woman to be more trustworthy than advice offered by a lesbian woman or another gay man. Overall, the results provide initial experimental evidence that relationships between gay men and straight women may be characterized by a mutual exchange of mating-relevant benefits in the absence of sexual interest or competition.

  9. Stereotactic biopsy of cerebellar lesions: straight versus oblique frame positioning.

    Science.gov (United States)

    Quick-Weller, Johanna; Brawanski, Nina; Dinc, Nazife; Behmanesh, Bedjahn; Kammerer, Sara; Dubinski, Daniel; Seifert, Volker; Marquardt, Gerhard; Weise, Lutz

    2017-10-26

    Biospies of brain lesions with unknown entity are an everyday procedure among many neurosurgical departments. Biopsies can be performed frame-guided or frameless. However, cerebellar lesions are a special entity with a more complex approach. All biopsies in this study were performed stereotactically frame guided. Therefore, only biopsies of cerebellar lesions were included in this study. We compared whether the frame was attached straight versus oblique and we focused on diagnostic yield and complication rate. We evaluated 20 patients who underwent the procedure between 2009 and 2017. Median age was 56.5 years. 12 (60%) Patients showed a left sided lesion, 6 (30%) showed a lesion in the right cerebellum and 2 (10%) patients showed a midline lesion. The stereotactic frame was mounted oblique in 12 (60%) patients and straight in 8 (40%) patients. Postoperative CT scan showed small, clinically silent blood collection in two (10%) of the patients, one (5%) patient showed haemorrhage, which caused a hydrocephalus. He received an external ventricular drain. In both patients with small haemorrhage the frame was positioned straight, while in the patient who showed a larger haemorrhage the frame was mounted oblique. In all patients a final histopathological diagnosis was established. Cerebellar lesions of unknown entity can be accessed transcerebellar either with the stereotactic frame mounted straight or oblique. Also for cerebellar lesions the procedure shows a high diagnostic yield with a low rate of severe complications, which need further treatment.

  10. Cardiorespiratory and metabolic responses during straight and bent knee cycling.

    Science.gov (United States)

    Mandroukas, K; Angelopoulou, N; Christoulas, K; Vrabas, I S

    2000-06-01

    This study examined the influence of knee angle on the cardiorespiratory system loading during submaximal and maximal stationary cycle ergometry. Experimental design and participants: eighteen untrained women (age: 21+/-1.88 years, weight: 57+/-5.75 kg, height: 165+/-5.03 cm, values are mean+/-SD) volunteered as subjects and underwent two-cycle ergometer incremental (Jaeger ER900) tests: 1) straight knee (180 degrees), 2) bent knee (140 degrees). oxygen uptake (VO2), ventilation (VE) and respiratory exchange ratio (RER) were measured continuously during each test using an open circuit spirometry and blood lactate concentration was determined by means of an enzymatic method. Comparing cycling with "straight knee" to cycling with "bent knee" at 50 W, heart rate (HR), V(E) and VO2 were significantly higher (10.6%, 12.5%, 17.8%). At 100 W, blood lactate was significantly lower (10.8%) while VO2 and RER was higher (5.5%, 7.1%). During maximal exercise, the total exercise time was significantly longer (11.2%) and VE, VO2 and HR were significantly higher during cycling with "straight knee" compared to cycling with "bent knee". No significant difference in peak lactate was evident between the two sitting positions. The results of this study indicate that cycling with bent knee requires lower oxygen uptake while pedaling with straight knee is the only way to reach VO2max during cycle testing, since the cardiorespiratory system is fully taxed.

  11. Improving the Lives of Students, Gay and Straight Alike: Gay-Straight Alliances and the Role of School Psychologists

    Science.gov (United States)

    Murphy, Heather Elise

    2012-01-01

    Lesbian, gay, bisexual, and transgender (LGBT) students face many risk factors every day when they enter their school's door. These students often fear for their safety at school, are victimized, have academic difficulties, suffer from issues with their identity development, and are at risk for suicide. School-based Gay-Straight Alliances (GSAs)…

  12. Efficient odd straight medium chain free fatty acid production by metabolically engineered Escherichia coli.

    Science.gov (United States)

    Wu, Hui; San, Ka-Yiu

    2014-11-01

    Free fatty acids (FFAs) can be used as precursors for the production of biofuels or chemicals. Different composition of FFAs will be useful for further modification of the biofuel/biochemical quality. Microbial biosynthesis of even chain FFAs can be achieved by introducing an acyl-acyl carrier protein thioesterase gene into E. coli. In this study, odd straight medium chain FFAs production was investigated by using metabolic engineered E. coli carrying acyl-ACP thioesterase (TE, Ricinus communis), propionyl-CoA synthase (Salmonella enterica), and β-ketoacyl-acyl carrier protein synthase III (four different sources) with supplement of extracellular propionate. By using these metabolically engineered E. coli, significant quantity of C13 and C15 odd straight-chain FFAs could be produced from glucose and propionate. The highest concentration of total odd straight chain FFAs attained was 1205 mg/L by the strain HWK201 (pXZ18, pBHE2), and 85% of the odd straight chain FFAs was C15. However, the highest percentage of odd straight chain FFAs was achieved by the strain HWK201 (pXZ18, pBHE3) of 83.2% at 48 h. This strategy was also applied successfully in strains carrying different TE, such as the medium length acyl-ACP thioesterase gene from Umbellularia californica. C11 and C13 became the major odd straight-chain FFAs. © 2014 Wiley Periodicals, Inc.

  13. The New SPS Extraction Channel for LHC and CNGS

    CERN Document Server

    Goddard, B; Schröder, G; Weterings, W; Uythoven, J

    2000-01-01

    The Large Hadron Collider (LHC) and CERN Neutrino to Gran Sasso (CNGS) projects require the construction of a new fast-extraction system in the long straight section LSS4 of the Super Proton Synchrotron (SPS) at CERN. A conventional DC septum magnet will be used, in conjunction with the installation of horizontal and vertical extraction bumpers, main quadrupoles with enlarged apertures, extraction kicker magnets and additional hardware protection, instrumentation, controls and electronics. The extraction channel must be able to accept the bright LHC proton beam at 450 GeV/c, and also the high intensity, large emittance fixed target CNGS proton beam at the nominal 400 GeV/c extraction momentum. This paper describes the extraction channel to be installed in 2003, and shows how the requirements for both the LHC and CNGS project can be met.

  14. Two-dimensional straightness measurement based on optical knife-edge sensing

    Science.gov (United States)

    Wang, Chen; Zhong, Fenghe; Ellis, Jonathan D.

    2017-09-01

    Straightness error is a parasitic translation along a perpendicular direction to the primary displacement axis of a linear stage. The parasitic translations could be coupled into other primary displacement directions of a multi-axis platform. Hence, its measurement and compensation are critical in precision multi-axis metrology, calibration, and manufacturing. This paper presents a two-dimensional (2D) straightness measurement configuration based on 2D optical knife-edge sensing, which is simple, light-weight, compact, and easy to align. It applies a 2D optical knife-edge to manipulate the diffraction pattern sensed by a quadrant photodetector, whose output voltages could derive 2D straightness errors after a calibration process. This paper analyzes the physical model of the configuration and performs simulations and experiments to study the system sensitivity, measurement nonlinearity, and error sources. The results demonstrate that the proposed configuration has higher sensitivity and insensitive to beam's vibration, compared with the conventional configurations without using the knife-edge, and could achieve ±0.25 μ m within a ±40 μ m measurement range along a 40 mm primary axial motion.

  15. Multitrajectory eikonal cross sections

    International Nuclear Information System (INIS)

    Turner, R.E.

    1983-01-01

    With the use of reference and distorted transition operators, a time-correlation-function representation of the inelastic differential cross section has recently been used to obtain distorted eikonal cross sections. These cross sections involve straight-line and reference classical translational trajectories that are unaffected by any internal-state changes which have occurred during the collision. This distorted eikonal theory is now extended to include effects of internal-state changes on the translational motion. In particular, a different classical trajectory is associated with each pair of internal states. Expressions for these inelastic cross sections are obtained in terms of time-ordered cosine and sine memory functions using the Zwanzig-Feshbach projection-operator method. Explicit formulas are obtained in the time-disordered perturbation approximation

  16. Tearing instability in a tokamak with a noncircular cross section

    Energy Technology Data Exchange (ETDEWEB)

    Arsenin, V. V., E-mail: arsenin-vv@nrcki.ru; Skovoroda, A. A., E-mail: skovoroda-aa@nrcki.ru [National Research Center Kurchatov Institute (Russian Federation)

    2016-12-15

    Using a straight-column model to describe tokamak plasma with a noncircular cross section, it is shown how to (i) find the boundary of tearing instability from the condition of existence of a magnetohydrodynamic plasma equilibrium different from that of a straight cylinder by solving a two-dimensional linear boundary-value problem with a second-order equation with respect to the flux coordinate and (ii) find the spatial structure of the tearing mode and the corresponding effective Δ' when there is only one resonance magnetic surface in the plasma for a given axial wavenumber by solving some kind of a boundary-value problem for the perturbation. The proposed approach is illustrated by numerical calculations for the case of an elliptical cross section as an example.

  17. Gay-Straight Alliance (GSA) Members' Engagement with Sex Education in Canadian High Schools

    Science.gov (United States)

    Lapointe, Alicia

    2014-01-01

    This paper offers an examination of gay-straight alliance (GSA) members' engagement with sex education, sexual health, and prejudice and discrimination in Canadian public high schools. It explores how five students' (four straight and one gay-identifying) participation in GSAs served as a springboard for learning about and challenging stereotypes;…

  18. The Effect of Scala Tympani Morphology on Basilar Membrane Contact With a Straight Electrode Array: A Human Temporal Bone Study.

    Science.gov (United States)

    Verberne, Juul; Risi, Frank; Campbell, Luke; Chambers, Scott; O'Leary, Stephen

    2017-01-01

    Scala tympani morphology influences the insertion dynamics and intra-scalar position of straight electrode arrays. Hearing preservation is the goal of cochlear implantation with current thin straight electrode arrays. These hug the lateral wall, facilitating full, atraumatic insertions. However, most studies still report some postoperative hearing loss. This study explores the influence of scala tympani morphology on array position relative to the basilar membrane and its possible contribution to postoperative hearing loss. Twenty-six fresh-frozen human temporal bones implanted with a straight electrode array were three-dimensionally reconstructed from micro-photographic histological sections. Insertion depth and the proximity between the array and basilar membrane were recorded. Lateral wall shape was quantified as a curvature ratio. Insertion depths ranged from 233 to 470 degrees. The mean first point of contact between the array and basilar membrane was 185 degrees; arrays tended to remain in contact with the membrane after first contacting it. Eighty-nine and 93% of arrays that reached the upper basal (>240-360 degrees) and second (>360-720 degrees) turns respectively contacted the basilar membrane in these regions. Scalar wall curvature ratio decreased significantly (the wall became steeper) from the basal to second turns. This shift correlated with a reduced distance between the array and basilar membrane. Scala tympani morphology influences the insertion dynamics and intra-scalar position of a straight electrode array. In addition to gross trauma of cochlear structures, contact between the array and basilar membrane and how this impacts membrane function should be considered in hearing preservation cases.

  19. Gender, Health Behavior, and Intimate Relationships: Lesbian, Gay, and Straight Contexts

    OpenAIRE

    Reczek, Corinne; Umberson, Debra

    2011-01-01

    Many studies focus on health behavior within the context of intimate ties. However, this literature is limited by reliance on gender socialization theory and a focus on straight (i.e., heterosexual) marriage. We extend this work with an analysis of relationship dynamics around health behavior in 20 long-term straight marriages as well as 15 gay and 15 lesbian long-term cohabiting partnerships in the United States (N=100 individual in-depth interviews). We develop the concept of “health behavi...

  20. Thoracolumbar movement in sound horses trotting in straight lines in hand and on the lunge and the relationship with hind limb symmetry or asymmetry.

    Science.gov (United States)

    Greve, L; Pfau, T; Dyson, S

    2017-02-01

    Equine movement symmetry is changed when turning, which may induce alterations in thoracolumbosacral kinematics; however, this has not previously been investigated. Our objectives were to document thoracolumbar movement in subjectively sound horses comparing straight lines with circles on both reins and to relate these observations to the objectively determined symmetry/asymmetry of hindlimb gait. Fourteen non-lame horses were assessed prospectively in a non-random, cross-sectional survey. The horses were trotted in straight lines and lunged on both reins and inertial sensor data collected at landmarks: withers, T13 and T18, L3, tubera sacrale, and left and right tubera coxae. Data were processed using published methods; angular motion range of motion (ROM; flexion-extension, axial rotation, lateral bending) and translational ROM (dorsoventral and lateral) and symmetry within each stride were assessed. The dorsoventral movement of the back exhibited a sinusoidal pattern with two oscillations per stride. Circles induced greater asymmetry in dorsoventral movement within each stride (mean ± standard deviation, up to 9 ± 6%) compared with straight lines (up to 6 ± 6%). The greatest amplitude of dorsoventral movement (119 ± 14 mm in straight lines vs. 126 ± 20 mm in circles) occurred at T13. Circles induced greater flexion-extension ROM (>1.3°; P = 0.002), lateral bending (>16°; P 16 mm; P = 0.002) compared with straight lines. Circles induced a movement pattern similar to an inside hindlimb lameness, which was significantly associated with the circle-induced greater asymmetry of dorsoventral movement of the thoracolumbar region (P = 0.03). Moving in a circle induces measurable changes in thoracolumbar movement compared with moving in straight lines, associated with alterations in the hindlimb gait. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Synthesis method based on solution regions for planar four bar straight line linkages

    International Nuclear Information System (INIS)

    Lai Rong, Yin; Cong, Mao; Jian you, Han; Tong, Yang; Juan, Huang

    2012-01-01

    An analytical method for synthesizing and selecting desired four-bar straight line mechanisms based on solution regions is presented. Given two fixed pivots, the point position and direction of the target straight line, an infinite number of mechanism solutions can be produced by employing this method, both in the general case and all three special cases. Unifying the straight line direction and the displacement from the given point to the instant center into the same form with different angles as parameters, infinite mechanism solutions can be expressed with different solution region charts. The mechanism property graphs have been computed to enable the designers to find out the involved mechanism information more intuitively and avoid aimlessness in selecting optimal mechanisms

  2. A new straight accelerator tube with U diaphragm

    International Nuclear Information System (INIS)

    Liu Jinhong; Lai Weiquan; Deng Yushen; Zhang Jidong

    1994-01-01

    After calculating the potential distribution and the particle trajectories in electrostatic accelerator tubes, a new straight tube with U diaphragm to suppress secondary particles is proposed. It's properties are demonstrated by the high voltage tests and the γ-rays measurements in the accelerator

  3. Morbidity Following Coloanal Anastomosis: A Comparison of Colonic J-Pouch vs Straight Anastomosis.

    Science.gov (United States)

    Brown, Shaun; Margolin, David A; Altom, Laura K; Green, Heather; Beck, David E; Kann, Brian R; Whitlow, Charles B; Vargas, Herschel David

    2018-02-01

    Low rectal tumors are often treated with sphincter-preserving resection followed by coloanal anastomosis. The purpose of this study was to compare the short-term complications following straight coloanal anastomosis vs colonic J-pouch anal anastomosis. Patients were identified who underwent proctectomy for rectal neoplasia followed by coloanal anastomosis in the 2008 to 2013 American College of Surgeons National Surgical Quality Improvement Program database. Demographic characteristics and 30-day postoperative complications were compared between groups. A national sample was extracted from the American College of Surgeons National Surgical Quality Improvement Project database. Inpatients following proctectomy and coloanal anastomosis for rectal cancer were selected. Demographic characteristics and 30-day postoperative complications were compared between the 2 groups. One thousand three hundred seventy patients were included, 624 in the straight anastomosis group and 746 in the colonic J-pouch group. Preoperative characteristics were similar between groups, with the exception of preoperative radiation therapy (straight anastomosis 35% vs colonic J-pouch 48%, p = 0.0004). Univariate analysis demonstrated that deep surgical site infection (3.7% vs 1.4%, p = 0.01), septic shock (2.25% vs 0.8%, p = 0.04), and return to the operating room (8.8% vs 5.0%, p = 0.0006) were more frequent in the straight anastomosis group vs the colonic J-pouch group. Major complications were also higher (23% vs 14%, p = 0.0001) and length of stay was longer in the straight anastomosis group vs the colonic J-pouch group (8.9 days vs 8.1 days, p = 0.02). After adjusting for covariates, major complications were less following colonic J-pouch vs straight anastomosis (OR, 0.57; CI, 0.38-0.84; p = 0.005). Subgroup analysis of patients who received preoperative radiation therapy demonstrated no difference in major complications between groups. This study had those limitations inherent to a

  4. Straight studs from southern pine veneer cores and cordwood

    Science.gov (United States)

    Peter Koch

    1968-01-01

    An economically feasible system has been developed for converting southern pine veneer cores into straight 8-foot studs (2). Prototype studs - two per core - were 100 percent SPIB stud grade and better.

  5. Axial velocity profiles and secondary flows of developing laminar flows in a straight connected exit region of a 180 .deg. square curved duct

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Hyun Chull; Lee, Heang Nam; Park, Gil Moon [Chosun Univ., Gwangju (Korea, Republic of)

    2005-10-01

    In the present study, characteristics of steady state laminar flows of a straight duct connected to a 180 .deg. curved duct were examined in the entrance region through experimental and numerical analyses. For the analysis, the governing equations of laminar flows in the Cartesian coordinate system were applied. Flow characteristics such as velocity profiles and secondary flows were investigated numerically and experimentally in a square cross-sectional straight duct by the PIV system and a CFD code (STARCD). For the PIV measurement, smoke particles produced from mosquito coils. The experimental data were obtained at 9 points dividing the test sections by 400 mm. Experimental and numerical results can be summarized as follows. 1) Reynolds number, Re was increased, dimensionless velocity profiles at the outer wall were increased due to the effect of the centrifugal force and secondary flows. 2) The intensity of a secondary flow became stronger at the inner wall rather than the outer wall regardless of Reynolds number. Especially, fluid dynamic phenomenon called conner impact were observed at dimensionless axial position, x/D{sub h}=50.

  6. School Climate, Individual Support, or Both? Gay-Straight Alliances and the Mental Health of Sexual Minority Youth

    Science.gov (United States)

    Walls, N. Eugene; Wisneski, Hope; Kane, Sarah

    2013-01-01

    Using a sample of 284 sexual minority youth and young adults, this paper examines the relationships between mental health variables, the absence or presence of a gay-straight alliance, and membership status in a gay-straight alliance. The results suggest that the presence of a gay-straight alliance in a school or college, rather than actual…

  7. A Straight-Talk Survival Guide for Colleges

    Science.gov (United States)

    Facione, Peter A.

    2009-01-01

    Times are very tough. The great majority of colleges are looking at 2009 and 2010 and beyond, in anticipation of the deepest budget cuts in more than a generation. But as bad as the financial situation may be, colleges can survive if they take swift and strong emergency action. It is time for some straight talk, starting with the realization that…

  8. A finite volume study for pressure waves propagation in a straight section of pipeline with caviation

    Directory of Open Access Journals (Sweden)

    C Silva

    2016-09-01

    Full Text Available The main objective of this research was to study the pressure waves propagation generated by a sudden closure of a valve in a straight pipe. The physical model consisted of a head tank that can be pressurized with air, and a copper pipe with a fast-closing ball valve on the downstream end of the line. The cavitation and fluid-structure interaction phenomena were integrated analytically into the one-dimensional continuity and momentum equations, by assuming that the fluid density and the flow area vary with pressure. These equations were solved through a high resolution finite volume method, in combination with others numerical methods such as Taylor series expansion, Newton method, Simpson's Rule and quadratic interpolation. Due to the complexity of the solution procedure, a computational code in FORTRAN 95 language was developed in order to obtain numerical solutions. Several discretizations of the computational grid were achieved to assess their impact on the solution. The model was validated with experimental data and analytic results obtained by other researchers. Several pressure values, in different points of pipe, were compared, and an excellent agreement was found for both cases.

  9. Investigation into the limitations of straightness interferometers using a multisensor-based error separation method

    Science.gov (United States)

    Weichert, Christoph; Köchert, Paul; Schötka, Eugen; Flügge, Jens; Manske, Eberhard

    2018-06-01

    The uncertainty of a straightness interferometer is independent of the component used to introduce the divergence angle between the two probing beams, and is limited by three main error sources, which are linked to each other: their resolution, the influence of refractive index gradients and the topography of the straightness reflector. To identify the configuration with minimal uncertainties under laboratory conditions, a fully fibre-coupled heterodyne interferometer was successively equipped with three different wedge prisms, resulting in three different divergence angles (4°, 8° and 20°). To separate the error sources an independent reference with a smaller reproducibility is needed. Therefore, the straightness measurement capability of the Nanometer Comparator, based on a multisensor error separation method, was improved to provide measurements with a reproducibility of 0.2 nm. The comparison results revealed that the influence of the refractive index gradients of air did not increase with interspaces between the probing beams of more than 11.3 mm. Therefore, over a movement range of 220 mm, the lowest uncertainty was achieved with the largest divergence angle. The dominant uncertainty contribution arose from the mirror topography, which was additionally determined with a Fizeau interferometer. The measured topography agreed within  ±1.3 nm with the systematic deviations revealed in the straightness comparison, resulting in an uncertainty contribution of 2.6 nm for the straightness interferometer.

  10. 49 CFR 238.119 - Rim-stamped straight-plate wheels.

    Science.gov (United States)

    2010-10-01

    ... input to the wheel during braking. (b) A rim-stamped straight-plate wheel shall not be used as a... that is periodically tread-braked for a short duration by automatic circuitry for the sole purpose of...

  11. Straight versus tortuous retinal arteries in relation to blood pressure and genetics

    DEFF Research Database (Denmark)

    Taarnhøj, N C B B; Munch, I C; Sander, B

    2008-01-01

    dizygotic same-sex healthy twin pairs, aged 20 to 46 years, who were characterised by determination of retinal vessel diameters, arterial blood pressure, blood glucose, body mass index, smoking habits and retinal arterial tortuosity, using a three-level grading scale (straight, wavy, tortuous). Heritability......BACKGROUND/AIMS: To assess the relative influence of genetic and environmental factors on retinal arterial tortuosity and the association between tortuosity and various health indices in healthy young to middle-aged persons. METHODS: This cross-sectional study included 57 monozygotic and 52...... accounting for the remaining 18% (CI(95 )8, 36%). Increasing values of mean arterial blood pressure and body mass index were both associated with decreasing levels of retinal arterial tortuosity. CONCLUSION: There was a large variation in tortuosity of retinal arteries in these healthy subjects...

  12. Setting the Record Straight on "High-Yield" Strategies

    Science.gov (United States)

    Marzano, Robert J.

    2009-01-01

    Widely credited with proposing nine "high-yield" instructional strategies, author Robert J. Marzano sets the record straight about the broader number of strategies identified by the research. He provides a list of 41 strategies and suggests more nuanced ways of using, observing, and evaluating them. (Contains 1 figure.)

  13. Steam cracking of hydrocarbons 3. Straight-run naphtha

    NARCIS (Netherlands)

    Bajus, M.; Vesely, V.; Leclercq, P.A.; Rijks, J.A.

    1980-01-01

    Steam cracking of straight-run naphtha from Romashkino crude oil was investigated in quartz and stainless steel reactors with a relatively large ratio of Inner surface to volume. The experiments were performed at atmospheric pressure at 780-800 OC for starting ratios of steam to naphtha between 0.5

  14. The Planning of Straight Line Trajectory in Robotics Using Interactive Graphics

    Directory of Open Access Journals (Sweden)

    Kesheng Wang

    1987-07-01

    Full Text Available The planning of straight line trajectory using the interactive computer graphics simulation of robot manipulator movement is discussed. This new approach to straight line motion planning improves the 'bound deviation joint paths' developed by R. M. Taylor (1979. The new approach has three characteristics: (1 linear interpolation in joint space; (2 unequal intervals for interpolating knot points; (3 using interactive computer graphics to assure that the maximum deviation in the whole segment is less than the pre-specified values. The structure and mathematical basis of a computer program developed for this purpose are presented.

  15. "Appearance potent"? A content analysis of UK gay and straight men's magazines.

    Science.gov (United States)

    Jankowski, Glen S; Fawkner, Helen; Slater, Amy; Tiggemann, Marika

    2014-09-01

    With little actual appraisal, a more 'appearance potent' (i.e., a reverence for appearance ideals) subculture has been used to explain gay men's greater body dissatisfaction in comparison to straight men's. This study sought to assess the respective appearance potency of each subculture by a content analysis of 32 issues of the most read gay (Attitude, Gay Times) and straight men's magazines (Men's Health, FHM) in the UK. Images of men and women were coded for their physical characteristics, objectification and nudity, as were the number of appearance adverts and articles. The gay men's magazines featured more images of men that were appearance ideal, nude and sexualized than the straight men's magazines. The converse was true for the images of women and appearance adverts. Although more research is needed to understand the effect of this content on the viewer, the findings are consistent with a more appearance potent gay male subculture. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  16. Insertion device development in the X13 straight of the NSLS X-Ray Ring

    International Nuclear Information System (INIS)

    Stefan, P.M.; Krinsky, S.; Kao, C.C.; Rakowsky, G.; Singh, O.; Solomon, L.

    1997-01-01

    On the NSLS X-Ray Storage Ring, the X13 straight section and beamline have been used for insertion-device-related R and D since 1990. The authors will describe three important projects: The Prototype Small-Gap Undulator (PSGU), the In-Vacuum Undulator (IVUN), and the Time Varying Elliptically Polarized Wiggler (EPW). The PSGU has successfully operated with a vertical aperture of only 3 mm, with minimal reduction in electron beam lifetime. The EPW has successfully run during regular user operations while switching at either 2 Hz or 100 Hz, with no adverse effects on other experiments. The IVUN project is a collaboration between NSLS and Spring-8, and installation is scheduled for May 1997

  17. Standing down Straight: Jump Rhythm Technique's Rhythm-Driven, Community-Directed Approach to Dance Education

    Science.gov (United States)

    Siegenfeld, Billy

    2009-01-01

    "Standing down straight" means to stand on two feet with both stability and relaxation. Using standing down straight as the foundation of class work, Jump Rhythm Technique offers a fresh alternative to conventional systems of dance study. It bases its pedagogy on three behaviors: grounding the body so that it can move with power and efficiency,…

  18. Modeling plasma flow in straight and curved solenoids

    International Nuclear Information System (INIS)

    Boercker, D.B.; Sanders, D.M.; Storer, J.; Falabella, S.

    1991-01-01

    The ''flux-tube'' model originated by Morozov is a very simple and numerically efficient method for simulating ion motion in plasma filters. In order to test its utility as a design tool, we compare the predictions of the model to recent experimental measurements of plasma flow in both straight and curved solenoids

  19. The need for the vegetarian crew for long-term LSS

    Science.gov (United States)

    Gorgolewski, S.

    The long-term space missions pose very stringent demands on the high degree of closure levels. One obvious requirements is to assure the human crew a steady state self-supporting and self-regenerating LSS environment. The strictly vegetarian crew is the primary requirement to minimize the cost and weight of the spacecraft. This ensures the minimal matter circulation problems, because we can also use for food as many as possible fuly edible plants with nex to none, non digestable plant tissues. One important task is to select a range of plants which should satisfy the nutritional needs of the crew for a long-term, in the range of several years. Preliminary fitotron experiments with lettuce, demonstrated that one can achieve this goal, with a plant which is wholy edible even with the roots. This has been achieved with the use of several teens times stronger electrical field, than the 130 V/m fair weather global atmospheric electrical field. More experiments are in progress for the extension of the list of such vegetarian food. The selection of suitable plants which meet these highly demanding selection criteria, has to be done and can be done in ground based experiments. Plants ensure one important requirements of a closed loop CO2 and O2 circulation with the vegetarian crew in the loop. Extensive research programs are needed for this purpose using large ground based instalations like the Biosphere 2. The success of the use of electrical fields as replacement of gravitational field in the fitotron which proved the dominating role over gravity, of several kV/m electical field intensities. It also proves the feasibility of improving the crop productivity in ground based greenhouses, provided that we do restore inside the missing in "normal" designs our global electrical field. The fair weather electrical field (not to mention the enhanced field) is the missing vital environmental factor which has been systematically "overlooked" in practically all greenhouses. It is

  20. Straight chiropractic philosophy as a barrier to Medicare compliance: a discussion of 5 incongruent issues.

    Science.gov (United States)

    Seaman, David R; Soltys, Jonathan R

    2013-12-01

    The purpose of this commentary is to discuss potential 5 factors within straight chiropractic philosophy and practice that may prevent Medicare compliance. The national Medicare Benefit Policy Manual and the Florida Local Coverage Determination were reviewed to identify documentation and conceptual issues regarding chiropractic practice. Five Medicare positions were contrasted with tenets of straight chiropractic philosophy. Based on Medicare's documentation requirements, Medicare defines subluxation and chiropractic practice from the perspective of treating spinal pain and related functional disability. In contrast, traditional straight chiropractic philosophy is not based on the treatment of spinal pain and disability or other symptomatic presentations. In this context, 5 potential areas of conflict are discussed. The Medicare version of chiropractic practice is not consistent with traditional straight chiropractic philosophy, which may play a role in preventing Medicare compliance. The chiropractic profession may need to consider the fashion in which "philosophy" as it relates to technique and practice is presented to students and doctors to facilitate compliance with the documentation requirements of Medicare.

  1. [The peculiar morphological features of the imprints of straight and wavy head hair dirtied with blood].

    Science.gov (United States)

    Leonova, E N; Nagornov, M N; Prokhorenko, A S

    2018-01-01

    The objective of the present study was to elucidate the specific morphological features of the imprints of blood-soaked straight and wavy head hair. The contact imprints of straight and wavy head hair dirtied with blood were obtained experimentally. The imprints of straight hair were shown to exhibit the elements in the form of the rectilinear and bow-shaped slightly bent stripes. The imprints of wavy hair were shaped as the arches, waves, circles, and a large number of various small elements, such as dashes and commas.

  2. Subjective Straight Ahead Orientation in Microgravity

    Science.gov (United States)

    Clement, G.; Reschke, M. F.; Wood, S. J.

    2015-01-01

    This joint ESA NASA study will address adaptive changes in spatial orientation related to the subjective straight ahead and the use of a vibrotactile sensory aid to reduce perceptual errors. The study will be conducted before and after long-duration expeditions to the International Space Station (ISS) to examine how spatial processing of target location is altered following exposure to microgravity. This study addresses the sensorimotor research gap to "determine the changes in sensorimotor function over the course of a mission and during recovery after landing."

  3. Study on an Undershot Cross-Flow Water Turbine with Straight Blades

    Directory of Open Access Journals (Sweden)

    Yasuyuki Nishi

    2015-01-01

    Full Text Available Small-scale hydroelectric power generation has recently attracted considerable attention. The authors previously proposed an undershot cross-flow water turbine with a very low head suitable for application to open channels. The water turbine was of a cross-flow type and could be used in open channels with the undershot method, remarkably simplifying its design by eliminating guide vanes and the casing. The water turbine was fitted with curved blades (such as the runners of a typical cross-flow water turbine installed in tube channels. However, there was ambiguity as to how the blades’ shape influenced the turbine’s performance and flow field. To resolve this issue, the present study applies straight blades to an undershot cross-flow water turbine and examines the performance and flow field via experiments and numerical analyses. Results reveal that the output power and the turbine efficiency of the Straight Blades runner were greater than those of the Curved Blades runner regardless of the rotational speed. Compared with the Curved Blades runner, the output power and the turbine efficiency of the Straight Blades runner were improved by about 31.7% and about 67.1%, respectively.

  4. Radiographic comparison of apical root resorption after orthodontic treatment between bidimensional and Roth straight-wire techniques.

    Science.gov (United States)

    Zawawi, Khalid H; Malki, Ghadah A

    2014-10-01

    The aim of this study was to compare the amount of root resorption after orthodontic treatment between the bidimensional and the Roth straight-wire techniques. Another objective was to compare the amount of root resorption in the whole sample studied and record the prevalence of root resorption. The sample consisted of 40 patients (age ranged between 11 and 18 years) with Angle Class II division 1 malocclusions, treated nonextraction. Twenty patients were treated with bidimensional technique and 20 with a 0.018-inch Roth straight-wire technique. Root lengths of the maxillary incisors were measured on pre- and post-treatment periapical radiographs. The results demonstrated that the bidimensional and Roth straight-wire groups showed significant root resorption after treatment, 1.11 (0.17) and 0.86 (0.05), respectively, P root shortening between the bidimensional and Roth straight-wire groups, there was no significant difference between the mean change from pre- to post-treatment between bidimensional group (mean = 1.00 ± 1.34) and Roth straight-wire group (mean = 0.88 ± 0.86), P = 0.63. Considering the whole sample, there was no root resoprtion in 32.5% of the analysed teeth. There was only mild resorption in 56.2%, moderate in 8.8% and severe in only 2.5% of the teeth. Treatment with the bidimensional technique did not produce an increase in the amount of root resorption. The prevalence and amount of root resorption was similar between bidimensional and Roth straight-wire techniques.

  5. Safeguards and security benefits of project straight-line

    International Nuclear Information System (INIS)

    Jaeger, C.D.; Waddoups, I.G.

    1995-01-01

    As a result of a number of events the inventory of fissile materials no longer in nuclear weapons in the United States is increasing. This has led to a growing concern regarding the potential for theft and/or diversion and accountability of this material. Straight-Line is a project whose purpose is to demonstrate a site-independent system to monitor stored nuclear material (e.g. plutonium) and integrate the collection, processing and dissemination of information regarding this material. Safeguards and security (S ampersand S) goals of this project include data transfer of information on nuclear material to appropriate users to enhance S ampersand S, continuous on-line accountability, reduction of hands-on access to nuclear materials, incorporation of information security technologies, and early detection of tampering or unauthorized material movement. This paper addresses threat considerations, S ampersand S requirements, S ampersand S objectives, and issues for the Straight-Line project. S ampersand S features and benefits of this project are discussed with respect to existing item monitoring systems and/or other material tracking systems being developed

  6. Cubic systems with invariant affine straight lines of total parallel multiplicity seven

    Directory of Open Access Journals (Sweden)

    Alexandru Suba

    2013-12-01

    Full Text Available In this article, we study the planar cubic differential systems with invariant affine straight lines of total parallel multiplicity seven. We classify these system according to their geometric properties encoded in the configurations of invariant straight lines. We show that there are only 17 different topological phase portraits in the Poincar\\'e disc associated to this family of cubic systems up to a reversal of the sense of their orbits, and we provide representatives of every class modulo an affine change of variables and rescaling of the time variable.

  7. Swan-neck versus straight peritoneal dialysis catheter: Long-term effect on patient and method survival.

    Science.gov (United States)

    Filiopoulos, V; Biblaki, D; Takouli, L; Dounavis, A; Hadjiyannakos, D; Vlassopoulos, D

    2016-09-01

    Peritoneal dialysis (PD) is limited mainly by a higher technique failure rate as compared to hemodialysis (HD), catheter malfunction being an important reason. Intra- and extra-peritoneal catheter configuration may be associated with mechanical and infectious complications affecting method survival. We report our experience with two extra-peritoneal catheter configurations: the straight and the swan-neck (SN) catheters. A total of 85 consecutive patients, 58 males and 27 females were included in the study. Among them, 26 were diabetics; 52 were treated with automated PD (APD) and 33 with continuous ambulatory PD (CAPD). Straight catheters were used in 38 patients (straight group) and SN catheters in 47 patients (SN group). Straight catheters were mostly used in the first 6-year period while SN catheters in the last 6-year period. The baseline demographics were similar between the two groups. A significantly higher frequency of APD use was observed in SN group. Technique survival was better with SN versus straight (log-rank test, P = 0.01) while patient and catheter survival were similar. A better technique survival is noted in our group of patients with SN catheters. An additional factor could be the significantly higher frequency of APD use in this group. Changes in PD solutions' composition could also contribute to improvement in technique survival. The outcome for patients and catheter types used was similar.

  8. Tetrahedron equations and the relativistic S-matrix of straight-strings in 2+1-dimensions

    International Nuclear Information System (INIS)

    Zamolodchikov, A.B.

    1981-01-01

    The quantum S-matrix theory of straight-strings (infinite one-dimensioanl objects like straight domain walls) in 2 + 1-dimensions is considered. The S-matrix is supposed to be purely elastic and factorized. The tetrahedron equations (which are the factorization conditions) are investigated for the special two-colour model. The relativistic three-string S-matrix, which apparently satisfies this tetrahedron equation, is proposed. (orig.)

  9. Polygonal Area of Prosthesis Support with Straight and Tilted Dental Implants in Edentulous Maxillae.

    Science.gov (United States)

    Wentaschek, Stefan; Lehmann, Karl Martin; Scheller, Herbert; Weibrich, Gernot; Behneke, Nikolaus

    2016-01-01

    The aim of this in vitro study was to assess the increase in the polygonal area of implant-retained prosthesis supports in edentulous maxillae with the use of tilted distal implants compared with the use of straight distal implants, using a variety of implant lengths. A total of 25 DICOM datasets of atrophic edentulous maxillae were provided. Bone augmentations in the molar region had to be avoided. Two straight reference implants were virtually inserted in the anterior region. Two additional implants were placed far distally on both sides (4 groups: [1] straight, 12-mm length; [2] straight, 10 mm; [3] straight, 8 mm; [4] tilted, 12-16 mm). The resulting implant-supported polygon was measured for each of the 4 groups using three-dimensional planning software. The mean sagittal depth of the supported polygon in Group 1 was 9.9 mm (standard deviation [SD] 4.4) on the right and 10.2 mm (SD 4.4) on the left, and it was 33.7 mm (SD 5.8) in width. For Group 2, the mean sagittal depth was 11.5 mm (SD 5.0) on the right and 11.9 mm (SD 4.7) on the left, and the width was 35.2 mm (SD 5.6). The measurements for Group 3 were 13.8 mm (SD 4.9) deep on the right, 13.8 mm (SD 5.1) deep on the left, and 37.0 mm (SD 5.4) in width. For Group 4, the depth was 15.8 mm (SD 4.9) on the right and 16.4 mm (SD 5.8) on the left, and the width was 39.0 mm (SD 5.1). The area of implant-retained prosthesis support can be enlarged by the use of tilted implants (12 to 16 mm in length, 42 to 45 degrees) compared to the use of straight 8-mm implants (resulting increase: about 15%).

  10. Comparison of Axillary Loop and Straight Grafts Patency and Their Complications for Hemodialylis Access

    Directory of Open Access Journals (Sweden)

    J KHoshnevis

    2011-08-01

    Full Text Available Introduction & Objective: Dialysis vascular access complications are important causes of morbidity in chronic hemodialysis patients. The aim of the present study was a comparison of auxillary loop and atraight grafts patency and its complications for hemodialysis access. Materials & Methods: In this cohort study conducted at Shahid Beheshti Medical University, 58 patients who underwent placement of loop or straight access grafts were included in the study. Demographics, primary and secondary patency rates and complications like thrombosis, infection, bleeding, steal syndrome and other complications were compared in these two groups. The collected data was analyzed by the SPSS statistical software using the chi-square test, t-test, and logistic regression. Results: Thrombosis rates were 51.1% and 53.8% in straight and loop groups respectively (P=0.862, steal syndrome rates were 2.2% and 7.7% in straight and loop groups respectively (P=0.341, psudoanevrism were 11.1% and 23.1% in straight and loop groups respectively (P=0.270, bleeding rates were 4.4% and 0% in straight and loop groups respectively (P=0.439, infection rate were 8.9% and 7.7% in straight and loop groups respectively (P=0.892, and primary patency rate after 1 month were 88.9% and 92.3% respectively (P=0.721, and primary patency rate after 24 month were 31% and 55.5% respectively (P=0.058. Secondary patency rate after 3 month were 75.6% and 92.3% respectively (P=0.189, and secondary patency rate after 24 month were 37.9% and 66.7% respectively (P=0.044. Conclusion: PTFE vascular graft seems to be an appropriate vascular access and is a promising alternative when upper extremity arteriovenous fistulas cannot be constructed. Additionally, there was no significant different between two groups for complications and early patency, but late patency was better in loop group. More study is necessary for final judgment.

  11. Accounting for straight parts effects on elbow's flexibilities in a beam type finite element program

    International Nuclear Information System (INIS)

    Millard, A.

    1983-01-01

    An extension of Von Karman's theory is applied to the calculations of the flexibility factor of a pipe bend terminated by a straight part or a flange. This analysis is restricted to the linear elastic deformation behaviour under in plane bending. Analytical solutions are given for the propagation of ovalization in the elbow and in the straight part. Considering the response of the piping structures, we note that the ovalization of the piping systems are reduced significantly when the straight parts or flanges effects are included. This results are presented in terms of global as well local flexibility factors. They have been compared to numerical results obtained by shell type finite elements method. A complete piping system is analyzed, for economical reasons, with a beam type approach. Also, we show how it is possible to take into account an elbow's flexibilities the straight parts effects by means of flexibilities factors introduced in a beam type elements. We have implemented this method in the computer program TEDEL. In some specific geometrical features, we compare solutions using shell type elements and our formulation. (orig.)

  12. Accounting for straight parts effects on elbow's flexibilities in a beam type finite element program

    International Nuclear Information System (INIS)

    Millard, A.; Vaghi, H.; Ricard, A.

    1983-08-01

    An extension of Von Karman's theory is applied to the calculations of the flexibility factor of a pipe bend terminated by a straight part or a flange. This analysis is restricted to the linear elastic deformation behaviour under in plane bending. Analytical solutions are given for the propagation of ovalization in the elbow and in the straight part. Considering the response of the piping structures, we note that the ovalization of the piping systems are reduced significantly when the straight parts or flanges effects are included. The results are presented in terms of global as well local flexibility factors. They have been compared to numerical results obtained by shell type finite element method. A complete piping system is analyzed, for economical reasons, with a beam type approach. Also, we show how it is possible to take into account on elbow's flexibilities the straight parts effects by means of flexibilities factors introduced in a beam type element. We have implemented this method in the computer program TEDEL. In some specific geometrical features, we compare solutions using shell type elements and our formulation

  13. Three-Axis Ground Reaction Force Distribution during Straight Walking.

    Science.gov (United States)

    Hori, Masataka; Nakai, Akihito; Shimoyama, Isao

    2017-10-24

    We measured the three-axis ground reaction force (GRF) distribution during straight walking. Small three-axis force sensors composed of rubber and sensor chips were fabricated and calibrated. After sensor calibration, 16 force sensors were attached to the left shoe. The three-axis force distribution during straight walking was measured, and the local features of the three-axis force under the sole of the shoe were analyzed. The heel area played a role in receiving the braking force, the base area of the fourth and fifth toes applied little vertical or shear force, the base area of the second and third toes generated a portion of the propulsive force and received a large vertical force, and the base area of the big toe helped move the body's center of mass to the other foot. The results demonstrate that measuring the three-axis GRF distribution is useful for a detailed analysis of bipedal locomotion.

  14. Straight proximal humeral nails are surrounded by more bone stock in comparison to bent nails in an experimental cadaveric study.

    Science.gov (United States)

    Günther, Christian Max; Müller, Peter Ernst; Mutschler, Wolf; Sprecher, Christoph Martin; Milz, Stefan; Braunstein, Volker

    2014-01-01

    In the management of proximal humeral fractures intramedullary implants with bent and straight shape of the proximal part of nail are available. Based on data from previous studies on bone distribution in the humeral head, we hypothesized, that higher densities might exist in the bone stock surrounding straight nails in comparison to their angulated counterparts. With a known positive correlation between bone density and mechanical stability, this could indicate potentially higher rigidity of osteosyntheses done with straight implants. We performed high resolution peripheral quantitative computed tomographies of the potential straight and bent implant bearing regions of 27 cadaveric proximal humeri. The acquired data were analyzed for differences between straight and bent Volumes of Interest as well as intra- and interindividual bone stock distribution. For both straight and bent volumes of interest a considerably declining bone mineral density was found in craniocaudal direction. Mean densities of bent volumes were significantly lower in comparison to their corresponding straight counterparts (p straight shaped implants can be assumed. Since we found a rapid decrease of bone density in cranio-caudal direction, intramedullary implants should be anchored as proximally in the subcortical area as possible to minimize the risk of displacement or cutout. The high correlation between the Volumes of Interest of the corresponding right and left sides could aid in preoperative planning when considering an intra- or extramedullary approach.

  15. A machine learning approach to galaxy-LSS classification - I. Imprints on halo merger trees

    Science.gov (United States)

    Hui, Jianan; Aragon, Miguel; Cui, Xinping; Flegal, James M.

    2018-04-01

    The cosmic web plays a major role in the formation and evolution of galaxies and defines, to a large extent, their properties. However, the relation between galaxies and environment is still not well understood. Here, we present a machine learning approach to study imprints of environmental effects on the mass assembly of haloes. We present a galaxy-LSS machine learning classifier based on galaxy properties sensitive to the environment. We then use the classifier to assess the relevance of each property. Correlations between galaxy properties and their cosmic environment can be used to predict galaxy membership to void/wall or filament/cluster with an accuracy of 93 per cent. Our study unveils environmental information encoded in properties of haloes not normally considered directly dependent on the cosmic environment such as merger history and complexity. Understanding the physical mechanism by which the cosmic web is imprinted in a halo can lead to significant improvements in galaxy formation models. This is accomplished by extracting features from galaxy properties and merger trees, computing feature scores for each feature and then applying support vector machine (SVM) to different feature sets. To this end, we have discovered that the shape and depth of the merger tree, formation time, and density of the galaxy are strongly associated with the cosmic environment. We describe a significant improvement in the original classification algorithm by performing LU decomposition of the distance matrix computed by the feature vectors and then using the output of the decomposition as input vectors for SVM.

  16. The Dugdale solution for two unequal straight cracks weakening

    Indian Academy of Sciences (India)

    A crack arrest model is proposed for an infinite elastic perfectly-plastic plate weakened by two unequal, quasi-static, collinear straight cracks. The Dugdale model solution is obtained for the above problem when the developed plastic zones are subjected to normal cohesive quadratically varying yield point stress. Employing ...

  17. LS1 Report: Successful tests

    CERN Multimedia

    CERN Bulletin

    2013-01-01

    At the PS Booster, the new beam dump and the associated shielding blocks surrounding it have been successfully installed and the installation of the beam transfer lines are now under way. The BI.SMH septum magnet has been successfully repaired following a confirmed vacuum leak.   At the PS, the consolidation of the seven main PS magnets has started, and the replacement of the old cooling and ventilation system continues to progress well. At the SPS, the replacement of the irradiated cables in Long Straight Section 1 (LSS1) of the SPS is now well under way and proceeding well. At the LHC, the Superconducting Magnets and Circuits Consolidation (SMACC) project remains ongoing. The closure of internal sleeves has begun in sector 7-8, and the shunt installations, a major consolidation activity, are progressing well in sector 8-1. The equivalent of more than one sector's outer sleeves (W) have been closed, and leak tests are in progress in several sub-sector...

  18. COMPARISON OF POSTOP SIA IN MSICS WITH STRAIGHT INCISION VERSUS FROWN INCISION

    Directory of Open Access Journals (Sweden)

    Shayana Bhumbla

    2017-05-01

    Full Text Available BACKGROUND Surgically-Induced Astigmatism (SIA is one of the commonest causes of poor postoperative vision even after uneventful cataract surgery. Recent advances have led to a newer concept of “refractive cataract surgery.” The aim of the study is to study the comparison of postop SIA in Manual Small Incision Cataract Surgery (MSICS with straight versus frown incision. MATERIALS AND METHODS 50 patients of cataract were divided into 2 groups (25 each - group A underwent MSICS with 6 mm straight incision, group B underwent MSICS with 6 mm frown incision. BCVA, keratometry readings were recorded with auto kerato-refractometer preop, at 1 week, 1 month, 3 months and SIA was calculated with SIA calculator version 2.1, a free software program. RESULTS Mean SIA in group A and B were - 1.14D versus 0.92D at 1 week; 1.26D versus 0.97D at 1 month; 1.29D versus 0.95D at 3 months. The difference was statistically significant at each follow up visit (p<0.05. CONCLUSION Frown incision gives lesser SIA than straight incision in MSICS.

  19. Radiologic findings of deep seated cerebral arteriovenous malformation with nonvisualization of straight sinus: focused on angiogram

    International Nuclear Information System (INIS)

    Won, Jong Boo; Park, Sung Ho; Hong, Jong Won; Kim, Yoo Kyoung; Shin, Mi Jeong; Baik, Seung Kuk; Choi, Han Yong; Kim, Bong Gi

    1999-01-01

    To analyze the radiologic-especially angiographic-findings of deep seated cerebral arteriovenous malformation(AVM) involving nonvisualized straight sinus. In six patients aged between 15 and 53 years with deep seated cerebral AVM, CT and MR images were retrospectively analyzed with regard to the following features : the presence of straight sinus, the location of AVM, and the occurrence of hemorrhage. Angiograms were analyzed for venous drainage routes of AVM, the appearance of veins, the presence of falcine sinus and venous drainage from normal deep brain parenchyme. In four patients who had undergone intravascular embolization therapy, pre- and post- embolization angiograms were compared. CT and MR images showed neither straight sinus nor thrombosis. AVMs were deeply seated in the brain, and in all cases there was cerebral hemorrhage. Angiograms disclosed that venous drainage of all AVMs occurred via the veins of Galen. In one case, venous flow via the falcine sinus to the superior sagittal sinus was noted, but in others, retrograde flow in the deep venous system was observed. Marked collateral routes followed in response to the obstruction of straight sinus included the basal vein of Rosenthal, the internal occipital, internal cerebral, and cerebellar hemispheric veins (which are Galenic afferents), and the inferior sagittal sinus. In all patients, contralateral routes were partially involved. Venous drainage from normal deep parenchyme through the transcerebral veins to the superficial venous system was noted, and in one case, straight sinus which had been observed on an angiogram five years earlier was no longer present. Angiography offers effective evaluation of the dynamic aspect of venous flow in cases involving deep-seated AVM, and of normal deep parenchyme in cases in which AVM involves nonvisualized straight sinus. Before intravascular treatment of AVM, venous flow must be carefully analyzed

  20. Excessive deformation and failure of straight parts and elbows

    International Nuclear Information System (INIS)

    Touboul, F.; Acker, D.

    1991-01-01

    The design rules for LMFBRs must cover the ranges of loading types and geometries wider than PWR Design Codes. Steam pipework does not differ between two reactor systems, but as far as sodium piping is concerned, usual PWR criteria may not be adequate. The LMFBR sodium piping is operated at high temperature and low pressure level. Moreover, these peculiar loadings require the geometrical characteristics completely different in the fact that the piping must be flexible but need not to be thick. For such piping components, the ultimate behavior depends much on the geometry. 170 experimental results on straight parts and 95 results on elbows were investigated. As for elbows, half of the tests were performed under in-plane closing moment. On the analysis of straight pipes and elbows, the experiments and the proposed expressions for the evaluation of collapse and instability moments are described, respectively. The application of the present study to the design rules and the criteria for various loading conditions are reported. It is difficult to experimentally distinguish between plastic instability and buckling. (K.I.)

  1. Strategies for Selecting Routes through Real-World Environments: Relative Topography, Initial Route Straightness, and Cardinal Direction.

    Directory of Open Access Journals (Sweden)

    Tad T Brunyé

    Full Text Available Previous research has demonstrated that route planners use several reliable strategies for selecting between alternate routes. Strategies include selecting straight rather than winding routes leaving an origin, selecting generally south- rather than north-going routes, and selecting routes that avoid traversal of complex topography. The contribution of this paper is characterizing the relative influence and potential interactions of these strategies. We also examine whether individual differences would predict any strategy reliance. Results showed evidence for independent and additive influences of all three strategies, with a strong influence of topography and initial segment straightness, and relatively weak influence of cardinal direction. Additively, routes were also disproportionately selected when they traversed relatively flat regions, had relatively straight initial segments, and went generally south rather than north. Two individual differences, extraversion and sense of direction, predicted the extent of some effects. Under real-world conditions navigators indeed consider a route's initial straightness, cardinal direction, and topography, but these cues differ in relative influence and vary in their application across individuals.

  2. Youth Empowerment and High School Gay-Straight Alliances

    OpenAIRE

    Russell, Stephen T.; Muraco, Anna; Subramaniam, Aarti; Laub, Carolyn

    2009-01-01

    In the field of positive youth development programs, “empowerment” is used interchangeably with youth activism, leadership, civic participation and self-efficacy. However, few studies have captured what empowerment means to young people in diverse contexts. This article explores how youth define and experience empowerment in youth-led organizations characterized by social justice goals: high school Gay-Straight Alliances (GSAs). Through focus group interviews, fifteen youth leaders of GSAs fr...

  3. Straight Vegetable Oil as a Diesel Fuel?

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-01-01

    Biodiesel, a renewable fuel produced from animal fats or vegetable oils, is popular among many vehicle owners and fleet managers seeking to reduce emissions and support U.S. energy security. Questions sometimes arise about the viability of fueling vehicles with straight vegetable oil (SVO), or waste oils from cooking and other processes, without intermediate processing. But SVO and waste oils differ from biodiesel (and conventional diesel) in some important ways and are generally not considered acceptable vehicle fuels for large-scale or long-term use.

  4. 27-GAUGE VITRECTOMY WOUND INTEGRITY: A Randomized Pilot Study Comparing Angled Versus Straight Entry in Fluid-Filled Vitrectomized Eyes.

    Science.gov (United States)

    Khan, M Ali; Durrani, Alia K; Hsu, Jason; Regillo, Carl D

    2018-04-01

    To compare clinical outcomes using angled versus straight trocar insertion during 27-gauge pars plana vitrectomy for epiretinal membrane. Pilot randomized controlled trial. Thirty eyes of 30 patients undergoing 27-gauge pars plana vitrectomy with membrane peeling for epiretinal membrane were randomized 1:1 to receive angled or straight trocar insertion. Intraocular pressure (IOP) and postoperative wound-related complications were compared. Fifteen eyes were randomized to each the angled and straight incision groups. No significant difference in phakic status (P = 0.71) or preoperative IOP (15.1 ± 3.4 vs. 14.6 ± 3.0 mmHg, P = 0.67) existed between groups. On postoperative Day 1, eyes in the straight group had lower IOP compared with the angled group (11.8 ± 3.9 vs. 15.3 ± 5.2 mmHg, P = 0.04) and a relative decrease in IOP compared with preoperative values (11.8 ± 3.9 vs. 15.1 ± 3.4 mmHg, P straight group) and serous choroidal detachment (1 eye, angled group). Eyes with straight incisions had transiently lower IOP on postoperative Day 1, possibly suggestive of subclinical wound leak in the very early postoperative period. Overall, rates of hypotony and sclerotomy-related complications were similarly low between wound construction strategies.

  5. Linear Motion Systems. A Modular Approach for Improved Straightness Performance

    NARCIS (Netherlands)

    Nijsse, G.J.P.

    2001-01-01

    This thesis deals with straight motion systems. A modular approach has been applied in order to find ways to improve the performance. The main performance parameters that are considered are position accuracy, repeatability and, to a lesser extent, cost. Because of the increasing requirements to

  6. Insurance-markets Equilibrium with Sequential Non-convex Straight-time and Over-time Labor Supply

    OpenAIRE

    Vasilev, Aleksandar

    2016-01-01

    This note describes the lottery- and insurance-market equilibrium in an economy with non-convex straight-time and overtime employment. In contrast to Hansen and Sargent (1988), the overtime-decision is a sequential one. This requires two separate insurance market to operate, one for straight-time work, and one for overtime. In addi- tion, given that the labor choice for regular and overtime hours is made in succession, the insurance market for overtime needs to open once the insurance market ...

  7. Bent solenoids for spectrometers and emittance exchange sections

    International Nuclear Information System (INIS)

    Norem, J.

    1999-01-01

    Bent solenoids can be used to transport low energy beams as they provide both confinement and dispersion of particle orbits. Solenoids are being considered both as emittance exchange sections and spectrometers in the muon cooling system as part of the study of the muon collider. They present the results of a study of bent solenoids which considers the design of coupling sections between bent solenoids to straight solenoids, drift compensation fields, aberrations, and factors relating to the construction, such as field ripple, stored energy, coil forces and field errors

  8. Modifications in straight wire treatment.

    Science.gov (United States)

    Cardona, Alvin

    2010-01-01

    Orthodontic treatments have been modified with each new generation of clinicians. Today the emphasis is on facial esthetics and healthy temporomandibular joints. With orthopedic treatment, we can develop dental arches to get the necessary space to align the teeth and we can reach adequate function and esthetics, all within relatively good stability. By combining two-phase treatment with low friction fixed orthodontics and super elastic wires we produce light but continuous forces and we can provide better treatment than before. These types of forces cause physiological and functional orthopedic orthodontic reactions. The purpose of this article is to demonstrate our fixed orthopedic and orthodontic approach called "Modified Straight Wire" or "Physiologic Arch Technique." This technique is very successful with our patients because it can exert slow and continuous forces with minimal patient cooperation.

  9. Comparison of conventional straight and swan-neck straight catheters inserted by percutaneous method for continuous ambulatory peritoneal dialysis: a single-center study.

    Science.gov (United States)

    Singh, Shivendra; Prakash, Jai; Singh, R G; Dole, P K; Pant, Pragya

    2015-10-01

    To evaluate the incidence of mechanical and infectious complications of conventional straight catheter (SC) versus swan-neck straight catheter (SNSC) implanted by percutaneous method. We retrospectively analyzed 45 catheter insertions being done by percutaneous method from January 1, 2011, to May 31, 2014. SC was inserted in 24 patients, and SNSC was inserted in 21 patients. Baseline characteristics for the two groups were similar with respect to age, sex and diabetic nephropathy as the cause for end-stage renal disease. Incidence of mechanical and infectious complications in SNSC group was found to be low as compared to the SC group and was statistically significant (1 in 11.6 patient months vs. 1 in 14.4 patient months, p = 0.02). Catheter migration was found to be the most common mechanical complication (20 %), and peritonitis was found to be the most common infectious complication in conventional SC group (27 episodes in 420 patient months vs. 11 episodes in 333 patient months, p = 0.03). The incidence of exit site and tunnel infection rates revealed no difference between the groups. SNSC insertion by percutaneous method is associated with low mechanical and infectious complications.

  10. Licensing support system preliminary needs analysis: Volume 1

    International Nuclear Information System (INIS)

    1989-01-01

    This Preliminary Needs Analysis, together with the Preliminary Data Scope Analysis (next in this series of reports), is a first effort under the LSS Design and Implementation Contract toward developing a sound requirements foundation for subsequent design work. Further refinements must be made before requirements can be specified in sufficient detail to provide a basis for suitably specific system specifications. This preliminary analysis of the LSS requirements has been divided into a ''needs'' and a ''data scope'' portion only for project management and scheduling reasons. The Preliminary Data Scope Analysis will address all issues concerning the content and size of the LSS data base; providing the requirements basis for data acquisition, cataloging and storage sizing specifications. This report addresses all other requirements for the LSS. The LSS consists of both computer subsystems and non-computer archives. This study addresses only the computer subsystems, focusing on the Access Subsystems. After providing background on previous LSS-related work, this report summarizes the findings from previous examinations of needs and describes a number of other requirements that have an impact on the LSS. The results of interviews conducted for this report are then described and analyzed. The final section of the report brings all of the key findings together and describes how these needs analyses will continue to be refined and utilized in on-going design activities. 14 refs., 2 figs., 1 tab

  11. Efficacy of Reciproc(®) and Profile(®) Instruments in the Removal of Gutta-Percha from Straight and Curved Root Canals ex Vivo.

    Science.gov (United States)

    Marfisi, Karem; Mercadé, Montserrat; Plotino, Gianluca; Clavel, Tatiana; Duran-Sindreu, Fernando; Roig, Miguel

    2015-01-01

    To compare the efficacy of Reciproc(®) (VDW GmbH) and ProFile(®) (Dentsply Maillefer) instruments at removing gutta-percha from straight and curved root canals ex vivo filled using the cold lateral condensation and GuttaMaster(®) (VDW GmbH) techniques. Forty mesial roots of mandibular molars with two curved canals and 80 single-rooted teeth with straight root canals, a total of 160 root canals, were randomly assigned to eight groups (canals per group = 20) according to filling technique, retreatment instrument and root canal curvature as follows: Group I, cold lateral condensation/ProFile(®)/straight; Group II, cold lateral condensation/ProFile(®)/curved; Group III, cold lateral condensation/Reciproc(®)/straight; Group IV, cold lateral condensation/Reciproc(®)/curved; Group V, GuttaMaster(®)/ProFile(®)/straight; Group VI, GuttaMaster(®)/ProFile(®)/curved; Group VII, GuttaMaster(®)/Reciproc(®)/straight; and Group VIII, GuttaMaster(®)/Reciproc(®)/curved. The following data were recorded: procedural errors, retreatment duration and canal wall cleanliness. Means and standard deviations were calculated and analysed using the Kruskal-Wallis test, one-way analysis of variance and Tukey's test (P straight (P = 0.0001) and curved (P = 0.0003) root canals. Reciproc(®) were statistically more effective than ProFile(®) instruments in removing GuttaMaster(®) from straight root canals (P = 0.021). Regardless of filling technique or retreatment instrument, gutta-percha was removed more rapidly from curved than from straight root canals (P = 0.0001). Neither system completely removed filling material from the root canals. Compared with ProFile(®) instruments, Reciproc(®) instruments removed GuttaMaster(®) filling material from straight and curved root canals more rapidly.

  12. Aeroelastic modeling of composite rotor blades with straight and swept tips

    Science.gov (United States)

    Yuan, Kuo-An; Friedmann, Peretz P.; Venkatesan, Comandur

    1992-01-01

    This paper presents an analytical study of the aeroelastic behavior of composite rotor blades with straight and swept tips. The blade is modeled by beam type finite elements. A single finite element is used to model the swept tip. The nonlinear equations of motion for the FEM are derived using Hamilton's principle and based on a moderate deflection theory and accounts for: arbitrary cross-sectional shape, pretwist, generally anisotropic material behavior, transverse shears and out-of-plane warping. Numerical results illustrating the effects of tip sweep, anhedral and composite ply orientation on blade aeroelastic behavior are presented. It is shown that composite ply orientation has a substantial effect on blade stability. At low thrust conditions, certain ply orientations can cause instability in the lag mode. The flap-torsion coupling associated with tip sweep can also induce aeroelastic instability in the blade. This instability can be removed by appropriate ply orientation in the composite construction. These results illustrate the inherent potential for aeroelastic tailoring present in composite rotor blades with swept tips, which still remains to be exploited in the design process.

  13. A new aeroelastic model for composite rotor blades with straight and swept tips

    Science.gov (United States)

    Yuan, Kuo-An; Friedmann, Peretz P.; Venkatesan, Comandur

    1992-01-01

    An analytical model for predicting the aeroelastic behavior of composite rotor blades with straight and swept tips is presented. The blade is modeled by beam type finite elements along the elastic axis. A single finite element is used to model the swept tip. The nonlinear equations of motion for the finite element model are derived using Hamilton's principle and based on a moderate deflection theory and accounts for: arbitrary cross-sectional shape, pretwist, generally anisotropic material behavior, transverse shears and out-of-plane warping. Numerical results illustrating the effects of tip sweep, anhedral and composite ply orientation on blade aeroelastic behavior are presented. Tip sweep can induce aeroelastic instability by flap-twist coupling. Tip anhedral causes lag-torsion and flap-axial couplings, however, its effects on blade stability is less pronounced than the effect due to sweep. Composite ply orientation has a substantial effect on blade stability.

  14. Demographic Trends and Advocacy Experiences of Gay-Straight Alliance Advisors

    Science.gov (United States)

    Graybill, Emily C.; Varjas, Kris; Meyers, Joel; Dever, Bridget V.; Greenberg, Daphne; Roach, Andrew T.; Morillas, Catalina

    2015-01-01

    Using an ecological model, the individual-, school-, and sociocultural-level characteristics that affect gay-straight alliance (GSA) advisors were examined in the current study. The formation of GSAs has been one way that schools have sought to improve the school climate for lesbian, gay, bisexual, and transgender (LGBT) youth. Limited information…

  15. Controllable synthesis of helical, straight, hollow and nitrogen-doped carbon nanofibers and their magnetic properties

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xun [State Key Laboratory of Coordination Chemistry, Nanjing National Laboratory of Microstructure, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093 (China); State Key Laboratory of Soil and Sustainable Agriculture, Institute of Soil Science, Chinese Academy of Sciences, Nanjing 210008 (China); Xu, Zheng, E-mail: zhengxu@nju.edu.cn [State Key Laboratory of Coordination Chemistry, Nanjing National Laboratory of Microstructure, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093 (China)

    2012-12-15

    Graphical abstract: The helical, straight and hollow carbon nanofibers can be selectively synthesized by adjusting either the reaction temperature or feed gas composition. Display Omitted Highlights: ► CNFs were synthesized via pyrolysis of acetylene on copper NPs. ► The helical, straight, hollow and N-doped CNFs can be selectively synthesized. ► The growth mechanism of different types of CNFs was proposed. -- Abstract: Carbon nanofibers (CNFs) with various morphologies were synthesized by catalytic pyrolysis of acetylene on copper nanoparticles which were generated from the in situ decomposition of copper acetylacetonate. The morphology of the pristine and acid-washed CNFs was investigated by field emission scanning electron microscope and high-resolution transmission electron microscope. Helical, straight and hollow CNFs can be selectively synthesized by adjusting either the reaction temperature or feed gas composition. The growth mechanism for these three types of CNFs was proposed.

  16. An in-situ measuring method for planar straightness error

    Science.gov (United States)

    Chen, Xi; Fu, Luhua; Yang, Tongyu; Sun, Changku; Wang, Zhong; Zhao, Yan; Liu, Changjie

    2018-01-01

    According to some current problems in the course of measuring the plane shape error of workpiece, an in-situ measuring method based on laser triangulation is presented in this paper. The method avoids the inefficiency of traditional methods like knife straightedge as well as the time and cost requirements of coordinate measuring machine(CMM). A laser-based measuring head is designed and installed on the spindle of a numerical control(NC) machine. The measuring head moves in the path planning to measure measuring points. The spatial coordinates of the measuring points are obtained by the combination of the laser triangulation displacement sensor and the coordinate system of the NC machine, which could make the indicators of measurement come true. The method to evaluate planar straightness error adopts particle swarm optimization(PSO). To verify the feasibility and accuracy of the measuring method, simulation experiments were implemented with a CMM. Comparing the measurement results of measuring head with the corresponding measured values obtained by composite measuring machine, it is verified that the method can realize high-precise and automatic measurement of the planar straightness error of the workpiece.

  17. Assessment of comparative skills between hand-assisted and straight laparoscopic colorectal training on an augmented reality simulator.

    Science.gov (United States)

    Leblanc, F; Delaney, C P; Neary, P C; Rose, J; Augestad, K M; Senagore, A J; Ellis, C N; Champagne, B J

    2010-09-01

    The aim of this study was to compare skills sets during a hand-assisted and straight laparoscopic colectomy on an augmented reality simulator. Twenty-nine surgeons, assigned randomly in 2 groups, performed laparoscopic sigmoid colectomies on a simulator: group A (n = 15) performed hand-assisted then straight procedures; group B (n = 14) performed straight then hand-assisted procedures. Groups were compared according to prior laparoscopic colorectal experience, performance (time, instrument path length, and instrument velocity changes), technical skills, and operative error. Prior laparoscopic colorectal experience was similar in both groups. Both groups had better performances with the hand-assisted approach, although technical skill scores were similar between approaches. The error rate was higher with the hand-assisted approach in group A, but similar between both approaches in group B. These data define the metrics of performance for hand-assisted and straight laparoscopic colectomy on an augmented reality simulator. The improved scores with the hand-assisted approach suggest that with this simulator a hand-assisted model may be technically easier to perform, although it is associated with increased intraoperative errors.

  18. Transition duct system with straight ceramic liner for delivering hot-temperature gases in a combustion turbine engine

    Science.gov (United States)

    Wiebe, David J.

    2017-05-16

    A transition duct system (10) for delivering hot-temperature gases from a plurality of combustors in a combustion turbine engine is provided. The system includes an exit piece (16) for each combustor. The exit piece may include a straight path segment (26) for receiving a gas flow from a respective combustor. A straight ceramic liner (40) may be inwardly disposed onto a metal outer shell (38) along the straight path segment of the exit piece. Structural arrangements are provided to securely attach the ceramic liner in the presence of substantial flow path pressurization. Cost-effective serviceability of the transition duct systems is realizable since the liner can be readily removed and replaced as needed.

  19. On the metallicity gradients of the Galactic disk as revealed by LSS-GAC red clump stars

    Science.gov (United States)

    Huang, Yang; Liu, Xiao-Wei; Zhang, Hua-Wei; Yuan, Hai-Bo; Xiang, Mao-Sheng; Chen, Bing-Qiu; Ren, Juan-Juan; Sun, Ning-Chen; Wang, Chun; Zhang, Yong; Hou, Yong-Hui; Wang, Yue-Fei; Yang, Ming

    2015-08-01

    Using a sample of over 70 000 red clump (RC) stars with 5%-10% distance accuracy selected from the LAMOST Spectroscopic Survey of the Galactic Anti-center (LSS-GAC), we study the radial and vertical gradients of the Galactic disk(s) mainly in the anti-center direction, covering a significant volume of the disk in the range of projected Galactocentric radius 7 ≤ RGC ≤ 14 kpc and height from the Galactic midplane 0 ≤ |Z| ≤ 3 kpc. Our analysis shows that both the radial and vertical metallicity gradients are negative across much of the volume of the disk that is probed, and they exhibit significant spatial variations. Near the solar circle (7 ≤ RGC ≤ 115 kpc), the radial gradient has a moderately steep, negative slope of -0.08 dex kpc-1 near the midplane (|Z| plane, suggesting that the outer disk may have experienced an evolutionary path different from that of the inner disk. The vertical gradients are found to flatten largely with increasing RGC. However, the vertical gradient of the lower disk (0 ≤ |Z| ≤ 1 kpc) is found to flatten with RGC quicker than that of the upper disk (1 < |Z| ≤ 3 kpc). Our results should provide strong constraints on the theory of disk formation and evolution, as well as the underlying physical processes that shape the disk (e.g. gas flows, radial migration, and internal and external perturbations).

  20. Preliminary estimates of dose and residual activation of selected components in ring collimation straight of the SNS

    International Nuclear Information System (INIS)

    Ludewig, H.; Catalan-Lasheras, N.; Simos, N.; Walker, J.; Mallen, A.; Wei, J.; Todosow, M.

    2000-01-01

    The highest doses to components in the SNS ring are expected to be to those located in the collimation straight section. In this paper the authors present estimated doses to magnets and cable located between collimators. In addition the buildup of relatively long half-life radioactive isotopes is estimated, following machine operation and shutdown. Finally, the potential dose to operators approaching the machine following operation and shutdown for four hours is made. The results indicate that selected components might require replacement after several years of full power operation. In addition, the reflection of gamma-rays from the tunnel walls contribute a non-negligible amount to the dose of an operator in the tunnel following machine shutdown

  1. An advanced straight tube heat exchanger in which a fluid flows at variable and elevated temperatures

    International Nuclear Information System (INIS)

    Mauget, C.; Benoit, G.; Stalport, G.

    1993-01-01

    Straight tube heat exchangers are used as steam generators in nuclear reactors such as in fast neutron nuclear power plants; elevated and highly variable temperatures induce very high thermal expansion constraints in these long straight tubes. In order to avoid the expansion problems, an expansion bellow is disposed between the heat exchanger and the collector tubular plate in such a way that the bundle differential expansions may be absorbed

  2. Comparison of anatomic vs. straight femoral stem design in total hip replacement - femoral canal fill in vivo.

    Science.gov (United States)

    de Boer, Friso A; Sariali, Elhadi

    2017-05-12

    The femoral canal fill between an anatomic and a straight prosthesis design in cementless total hip arthroplasty (THA) was compared. We hypothesised that the anatomic SPS stem has higher proximal fill and lesser distal fill than the straight stem. The femoral canal fill was measured on 3 months routine postoperative x-rays at 5 levels of the stem in 50 consecutive patients, aged 35-83 years, who underwent 56 THA procedures by a single surgeon in this hospital. 22 patients received a straight design Ceramconcept Global stem, 34 patients received an anatomic design Symbios SPS stem. Both anteroposterior (AP) and lateral x-rays were combined to suggest a 3-D measurement. On the AP x-rays, the canal fill was significantly higher using the anatomic design stem at the proximal measurement levels, and was significantly higher at the distal levels using the straight stem. With the AP and lateral x-rays combined, the canal fill at the proximal levels was also significantly higher in the anatomic groups, nonsignificantly lower at the central level and significantly lower at the distal levels. In THA surgery, achieving high fill at the metaphysis of the femur and less fill at the diaphysis has been suggested to result in satisfactory outcome and high stability of the prosthesis. This study demonstrated that, compared to straight stem design, an anatomically designed stem has a significantly higher metaphyseal femoral canal fill.

  3. Secondary Flow Phenomena in Rotating Radial Straight Pipes

    OpenAIRE

    Cheng, K. C.; Wang, Liqiu

    1995-01-01

    Flow visualization results for secondary flow phenomena near the exit of a rotating radial-axis straight pipe (length ࡁ = 82 cm, inside diameter d = 3.81 cm, ࡁ/d 21.52) are presented to study the stabilizing (relaminarization) and destabilizing (early transition from laminar to turbulent flow) effects of Coriolis forces for Reynolds numbers Re = 500 ∼ 4,500 and rotating speeds n = 0 ∼ 200 rpm. The flow visualization was realised by smoke injection method. The main features of the trans...

  4. Equilibrium charge distribution on a finite straight one-dimensional wire

    Science.gov (United States)

    Batle, Josep; Ciftja, Orion; Abdalla, Soliman; Elhoseny, Mohamed; Alkhambashi, Majid; Farouk, Ahmed

    2017-09-01

    The electrostatic properties of uniformly charged regular bodies are prominently discussed on college-level electromagnetism courses. However, one of the most basic problems of electrostatics that deals with how a continuous charge distribution reaches equilibrium is rarely mentioned at this level. In this work we revisit the problem of equilibrium charge distribution on a straight one-dimensional (1D) wire with finite length. The majority of existing treatments in the literature deal with the 1D wire as a limiting case of a higher-dimensional structure that can be treated analytically for a Coulomb interaction potential between point charges. Surprisingly, different models (for instance, an ellipsoid or a cylinder model) may lead to different results, thus there is even some ambiguity on whether the problem is well-posed. In this work we adopt a different approach where we do not start with any higher-dimensional body that reduces to a 1D wire in the appropriate limit. Instead, our starting point is the obvious one, a finite straight 1D wire that contains charge. However, the new tweak in the model is the assumption that point charges interact with each other via a non-Coulomb power-law interaction potential. This potential is well-behaved, allows exact analytical results and approaches the standard Coulomb interaction potential as a limit. The results originating from this approach suggest that the equilibrium charge distribution for a finite straight 1D wire is a uniform charge density when the power-law interaction potential approaches the Coulomb interaction potential as a suitable limit. We contrast such a finding to results obtained using a different regularised logarithmic interaction potential which allows exact treatment in 1D. The present self-contained material may be of interest to instructors teaching electromagnetism as well as students who will discover that simple-looking problems may sometimes pose important scientific challenges.

  5. Equilibrium charge distribution on a finite straight one-dimensional wire

    International Nuclear Information System (INIS)

    Batle, Josep; Ciftja, Orion; Abdalla, Soliman; Elhoseny, Mohamed; Farouk, Ahmed; Alkhambashi, Majid

    2017-01-01

    The electrostatic properties of uniformly charged regular bodies are prominently discussed on college-level electromagnetism courses. However, one of the most basic problems of electrostatics that deals with how a continuous charge distribution reaches equilibrium is rarely mentioned at this level. In this work we revisit the problem of equilibrium charge distribution on a straight one-dimensional (1D) wire with finite length. The majority of existing treatments in the literature deal with the 1D wire as a limiting case of a higher-dimensional structure that can be treated analytically for a Coulomb interaction potential between point charges. Surprisingly, different models (for instance, an ellipsoid or a cylinder model) may lead to different results, thus there is even some ambiguity on whether the problem is well-posed. In this work we adopt a different approach where we do not start with any higher-dimensional body that reduces to a 1D wire in the appropriate limit. Instead, our starting point is the obvious one, a finite straight 1D wire that contains charge. However, the new tweak in the model is the assumption that point charges interact with each other via a non-Coulomb power-law interaction potential. This potential is well-behaved, allows exact analytical results and approaches the standard Coulomb interaction potential as a limit. The results originating from this approach suggest that the equilibrium charge distribution for a finite straight 1D wire is a uniform charge density when the power-law interaction potential approaches the Coulomb interaction potential as a suitable limit. We contrast such a finding to results obtained using a different regularised logarithmic interaction potential which allows exact treatment in 1D. The present self-contained material may be of interest to instructors teaching electromagnetism as well as students who will discover that simple-looking problems may sometimes pose important scientific challenges. (paper)

  6. Shielded transient self-interaction of a bunch entering a circle from a straight path

    International Nuclear Information System (INIS)

    Li, R.; Bohn, C.L.; Bisognano, J.J.

    1997-01-01

    When a short (mm-length) bunch with high (nC-regime) charge is transported through a magnetic bending system, self-interaction via coherent synchrotron radiation (CSR) and space charge may alter the bunch dynamics significantly. The authors consider a Gaussian rigid-line-charge bunch following a straight-path trajectory into a circle, with the trajectory centered between two infinite, parallel, perfectly conducting plates. Transients associated with CSR and space charge generated from source particles both on the straight path and the circle are calculated, and their net effect on the radiated power is contrasted with that of shielded steady-state CSR

  7. Novel Straight and Circular Road Driving Control of Electric Power Assisted Wheelchair Based on Fuzzy Algorithm

    Science.gov (United States)

    Seki, Hirokazu; Tadakuma, Susumu

    This paper describes a novel straight and circular road driving control scheme for electric power assisted wheelchairs. “Electric power assisted wheelchair” which assists the driving force by electric motors is expected to be widely used as a mobility support system for elderly people and disabled people, however, the performance of the straight and circular road driving must be further improved because the two wheels drive independently. This paper proposes a novel driving control scheme based on fuzzy algorithm to realize the stable and reliable driving on straight and circular roads. The suitable assisted torque of the right and left wheels is determined by fuzzy algorithm based on the posture angular velocity of the wheelchair and the human input torque proportion of the right and left wheels. Some experiments on the practical roads show the effectiveness of the proposed control system.

  8. Review of the analysis methods of surface crack for straight pipe and elbow

    International Nuclear Information System (INIS)

    Kim, H. S.; Jang, Y. S.; Jin, T. E.

    1999-01-01

    The objective of this paper is to find out optimum EPFM analysis methods of straight pipe and elbow by comparison of load-carrying capacities. To do this, analytical and finite element analyses were performed and then these results compared with the ones in the literatures and experimental data to verify the validity of the analysis results. Comparison results showed that NSC method for straight pipe and SC.ELB2 method for elbow were appropriate ones among analytical methods except FEM to predict load-carrying capacities. However, the trend of prediction results scattered according to the analysis conditions such as geometry and material as well as analytical methods, it is necessary for cautious application of the analytical methods

  9. The free energy profile of tubulin straight-bent conformational changes, with implications for microtubule assembly and drug discovery.

    Directory of Open Access Journals (Sweden)

    Lili X Peng

    2014-02-01

    Full Text Available αβ-tubulin dimers need to convert between a 'bent' conformation observed for free dimers in solution and a 'straight' conformation required for incorporation into the microtubule lattice. Here, we investigate the free energy landscape of αβ-tubulin using molecular dynamics simulations, emphasizing implications for models of assembly, and modulation of the conformational landscape by colchicine, a tubulin-binding drug that inhibits microtubule polymerization. Specifically, we performed molecular dynamics, potential-of-mean force simulations to obtain the free energy profile for unpolymerized GDP-bound tubulin as a function of the ∼12° intradimer rotation differentiating the straight and bent conformers. Our results predict that the unassembled GDP-tubulin heterodimer exists in a continuum of conformations ranging between straight and bent, but, in agreement with existing structural data, suggests that an intermediate bent state has a lower free energy (by ∼1 kcal/mol and thus dominates in solution. In agreement with predictions of the lattice model of microtubule assembly, lateral binding of two αβ-tubulins strongly shifts the conformational equilibrium towards the straight state, which is then ∼1 kcal/mol lower in free energy than the bent state. Finally, calculations of colchicine binding to a single αβ-tubulin dimer strongly shifts the equilibrium toward the bent states, and disfavors the straight state to the extent that it is no longer thermodynamically populated.

  10. Straight and chopped DC performance data for a reliance EV-250AT motor with a General Electric EV-1 controller

    Science.gov (United States)

    Edie, P. C.

    1981-01-01

    Straight and chopped DC motor performances for a Reliance EV-250AT motor with an EV-1 controller were examined. Effects of motor temperature and operating voltage are shown. It is found that the maximum motor efficiency is approximately 85% at low operating temperatures in the straight DC mode. Chopper efficiency is 95% under all operating conditions. For equal speeds, the motor operated in the chopped mode develops slightly more torque and draws more current than it does in the straight DC mode.

  11. A model based approach to reference-free straightness measurement at the Nanometer Comparator

    Science.gov (United States)

    Weichert, C.; Stavridis, M.; Walzel, M.; Elster, C.; Wiegmann, A.; Schulz, M.; Köning, R.; Flügge, J.; Tutsch, R.

    2009-06-01

    The Nanometer Comparator is the PTB reference length measuring machine for high precision calibrations of line scales and encoder systems. Up to now the Nanometer Comparator allows to measure the position of line structures in one dimension only. For high precision characterisations of masks, scales and incremental encoders, the measurement of the straightness of graduations is a requirement from emerging lithography techniques. Therefore the Nanometer Comparator will be equipped with an additional short range measurement system in the Y-direction, realized as a single path plane mirror interferometer and supposed to achieve sub-nm uncertainties. To compensate the topography of the Y-mirror, the Traceable Multi Sensor (TMS) method will be implemented to achieve a reference-free straightness measurement. Virtual experiments are used to estimate the lower accuracy limit and to determine the sensitive parameters. The virtual experiments contain the influence of the positioning devices, interferometer errors as well as non-perfect adjustment and fabrication of the machine geometry. The whole dynamic measurement process of the Nanometer Comparator including its influence on the TMS analysis, e.g. non-equally spaced measurement points, is simulated. We will present the results of these virtual experiments as well as the most relevant error sources for straightness measurement, incorporating the low uncertainties of the existing and planned measurement systems.

  12. Straight spinning cosmic strings in Brans-Dicke gravity

    Science.gov (United States)

    Dos Santos, S. Mittmann; da Silva, J. M. Hoff; Cindra, J. L.

    2018-03-01

    An exact solution of straight spinning cosmic strings in Brans-Dicke theory of gravitation is presented. The possibility of the existence of closed time-like curves around these cosmic strings is analyzed. Furthermore, the stability about the formation of the topological defect discussed here is checked. It is shown that the existence of a suitable choice for the integration constants in which closed time-like curves are not allowed. We also study the (im)possibility of using the obtained spacetime in the rotational curves problem.

  13. Transitions in pedestrian fundamental diagrams of straight corridors and T-junctions

    International Nuclear Information System (INIS)

    Zhang, J; Klingsch, W; Schadschneider, A; Seyfried, A

    2011-01-01

    Many observations of pedestrian dynamics, including various self-organization phenomena, have been reproduced successfully by different models. But the empirical databases for quantitative calibration are still insufficient, e.g. the fundamental diagram as one of the most important relationships displays non-negligible differences among various studies. To improve this situation, experiments in straight corridors and T-junctions are performed. Four different measurement methods are defined to study their effects on the fundamental diagram. It is shown that they have minor influences for ρ −2 but only the Voronoi method is able to resolve the fine structure of the fundamental diagram. This enhanced measurement method permits us to observe the occurrence of a boundary-induced phase transition. For corridors of different widths we found that the specific flow concept works well for ρ −2 . Moreover, we illustrate the discrepancies between the fundamental diagrams of a T-junction and a straight corridor

  14. Radiation-induced desulfurization of Arabian crude oil and straight-run diesel

    International Nuclear Information System (INIS)

    Basfar, A.A.; Mohamed, K.A.

    2011-01-01

    Radiation-induced desulfurization of four types of Arabian crude oils (heavy, medium, light and extra light) and straight-run diesel (SRD) was investigated over the range of 10-200 kGy. Results show that gamma radiation processing at absorbed doses up to 200 kGy without further treatment is not sufficient for desulfurization. However, the combination of gamma-irradiation with other physical/chemical processes (i.e. L/L extraction, adsorption and oxidation) may be capable of removing considerable levels of sulfur compounds in the investigated products. Currently, this approach of combined radiation/physical/chemical processes is under investigation. The findings of these attempts will be reported in the future. - Highlights: → Irradiation effect on desulfurization in Arabian crude oils and straight-run diesel was investigated. → No noticeable changes in sulfur content after irradiation up to 200 kGy were observed. → Stricter regulations on sulfur levels in fuels motivate search for improved desulfurization processes. → Limited investigations on radiation-induced desulfurization of oil products are conducted.

  15. Restoration of lumbopelvic sagittal alignment and its maintenance following transforaminal lumbar interbody fusion (TLIF): comparison between straight type versus curvilinear type cage.

    Science.gov (United States)

    Kim, Jong-Tae; Shin, Myung-Hoon; Lee, Ho-Jin; Choi, Du-Yong

    2015-11-01

    To evaluate a radiological and clinical difference between the curvilinear type cages compared to the straight type cages for the restoration of lumbopelvic sagittal alignment and its maintenance after transforaminal lumbar interbody fusion (TLIF) procedure. 68 patients who underwent single-level TLIF using either the straight type or curvilinear type cage were retrospectively reviewed. Assessment of the lumbopelvic parameters and the height of disc space was performed before surgery as well as 2 days, 6 and 12 months after surgery. Clinical outcome was assessed using VAS and ODI. The curvilinear type cages were positioned more anteriorly than the straight type. Restoration of the segmental lordosis (SL) in the curvilinear group was significantly greater than the straight group and at 12 months of follow-up, the straight group showed greater decrease in the disc height than the curvilinear group. The straight group failed to show improvement of lumbar lordosis (LL), while the curvilinear group showed significant restoration of LL and could maintain it to the 6 months of follow-up. In both groups, pelvic tilt was significantly decreased and it lasted to 6 months in the straight group; whereas in the curvilinear group, it was maintained to the last follow-up of 12 months. There were no significant differences between the two groups in mean VAS and ODI score over the follow-up period. This study demonstrates that the curvilinear type cage is superior to the straight type cage in improving the SL and maintaining both the restored lumbopelvic parameters and elevated disc height. These results could be attributable to the anterior position of the curvilinear cage which permits easy restoration of segmental lordosis and less sinking of cages.

  16. Available friction of ladder shoes and slip potential for climbing on a straight ladder.

    Science.gov (United States)

    Chang, Wen-Ruey; Chang, Chien-Chi; Matz, Simon

    2005-07-15

    Straight ladder accidents are a major safety problem. As a leading cause of injuries involving straight ladders, slips at the ladder base occur when the required friction exceeds the available friction at the ladder shoe and floor interface. The objectives of this experiment were to measure the available friction at the base of a portable straight ladder in contact with a floor and to estimate the slip potential of the ladder. The results of friction measurements indicated that the measured friction coefficient on the oily surfaces differed among the six commercially available ladder shoes evaluated. A statistical model was used to compare the available friction results from the current study with the friction requirements under different climbing conditions from a previous study based on their stochastic distributions to estimate the slip potential at the base of the ladder. The results showed that different climbing conditions used in the previous study could be supported by available friction on dry surfaces. However, when the ladder was put onto oily surfaces, resulting in a significant reduction in the available friction due to contamination, slip potential was significantly increased.

  17. Effect of Hartmann layer resolution for MHD flow in a straight ...

    Indian Academy of Sciences (India)

    851–861. c Indian Academy of Sciences. Effect of Hartmann layer resolution for MHD flow in a straight, conducting duct at high Hartmann numbers. SHARANYA SUBRAMANIAN1,∗, P K SWAIN2,. A V DESHPANDE1 and P SATYAMURTHY2. 1Mechanical Engineering Department, Veermata Jijabai Technological Institute,.

  18. Straight A's: Public Education Policy and Progress. Volume 12, Number 2

    Science.gov (United States)

    Amos, Jason, Ed.

    2012-01-01

    "Straight A's: Public Education Policy and Progress" is a biweekly newsletter that focuses on education news and events both in Washington, DC and around the country. The following articles are included in this issue: (1) Waiving Away High School Graduation Rate Accountability?: State NCLB Waiver Proposals Threaten to Weaken…

  19. Straight-run vs. sex separate rearing for 2 broiler genetic lines Part 1: Live production parameters, carcass yield, and feeding behavior.

    Science.gov (United States)

    Da Costa, M J; Zaragoza-Santacruz, S; Frost, T J; Halley, J; Pesti, G M

    2017-08-01

    The objective of this experiment was to evaluate the effects of raising broilers under sex separate and straight-run conditions for 2 broiler strains. Day-old Ross 308 and Ross 708 chicks (n = 1,344) were separated by sex and placed in 48 pens according to the rearing type: sex separate (28 males or 28 females) or straight-run (14 males + 14 females). There were 3 dietary phases: starter (zero to 17 d), grower (17 to 32 d), and finisher (32 to 48 d). Birds' individual BW and feed intakes were measured at 12, 17, 25, 32, 42, and 48 d to evaluate performance. At 33, 43, and 49 d, 4 birds per pen were sampled for carcass yield evaluation. Additionally, from 06:00 to 06:30, 13:00 to 13:30, and 22:00 to 22:30, video records were taken to assess behavior at 45 days. Data were analyzed as CRD with a 2 × 3 factorial arrangement of treatments over time. Throughout the experiment Ross 308 were heavier than the 708, and after 17 d, male pens had the heavier birds, followed by straight-run and then females. Straight-run pens had higher BW CV in comparison with sex separate pens. Sex separate male BW was negatively impacted from 17 to 32 days. On the other hand, females raised sex separate were heavier than females raised straight-run with lower CV from 25 to 41 days. Post 25 d, FCR was the lowest in male pens whereas feed intake was the highest for these pens after 17 days. Overall, males had total carcass cut-up weights higher than straight-run and females at the 3 processing times. The Ross 708 had higher white meat yields, whereas 308 had higher yields for dark meat. Feeding behavior results were not consistent over time. However, from 13:00 to 13:30, birds in female pens spent more time eating, followed by straight-run and then males. In conclusion, raising females in a straight-run system negatively impacted performance and CV, whereas males benefited from straight-run rearing, with the differences being possibly related to feeder space competition. © 2017

  20. Free-boundary stability of straight stellarators

    International Nuclear Information System (INIS)

    Barnes, D.C.; Cary, J.R.

    1984-02-01

    The sharp-boundary model is used to investigate the stability of straight stellarators to free-boundary, long-wavelength modes. To correctly analyze the heliac configuration, previous theory is generalized to the case of arbitrary helical aspect ratio (ratio of plasma radius to periodicity lengths). A simple low-β criterion involving the vacuum field and the normalized axial current is derived and used to investigate a large variety of configurations. The predictions of this low-β theory are verified by numerical minimization of deltaW at arbitrary β. The heliac configuration is found to be remarkably stable, with a critical β of over 15% determined by the lack of equilibrium rather than the onset of instability. In addition, other previously studied systems are found to be stabilized by net axial plasma current

  1. Trends in Canadian Newspaper Coverage of Gay-Straight Alliances, 2000-2009

    Science.gov (United States)

    Herriot, Lindsay

    2011-01-01

    Gay-straight alliances (GSAs) in Canadian public schools have gained considerable attention from print media since reports first surfaced in the year 2000. This study tracked and analyzed Canadian newspaper reporting about GSA creation. It summarized the shift in public opinion toward lesbian, gay, bisexual, transgender, and queer (LGBTQ) youth…

  2. Does spinal stenosis correlate with MRI findings and pain, psychologic factor and quality of life?

    Science.gov (United States)

    Lee, Mi Young; Jung, Sung Won; Lee, Su Yong

    2015-01-01

    Background To investigate and analyze MRI findings in relation to visual analogue scale (VAS), Oswestry Disability Index (ODI), psychological-factor, sleep-quality, and Short-Form Health Survey (SF-36) scores among patients with central lumbar spinal stenosis (LSS) for the purpose of elucidating a correlation. Methods From July 2013 to May 2014, 117 consecutive patients with central LSS were included in this study. All of the MRIs were evaluated by one of the authors, and the evaluated items were the dural sac cross-sectional area (DSCSA), the number of stenotic levels, and the presence and levels of spondylolisthesis. The ODI, VAS, 36-item SF-36, Beck Depression Inventory (BDI), Beck Anxiety Inventory (BAI), and Pittsburgh Sleep Quality Index (PSQI) questionnaires were used to evaluate the participants. Results There are no correlations between the ODI, VAS, BDI, BAI, PSQI, and SF-36 scores and the minimum DSCSA; however, a significant correlation was found between the ODI scores and multilevel LSS. The BDI, BAI, and PSQI scores are higher for multilevel LSS compared with single-level LSS, but the difference of this mean value is not statistically significant. Conclusions A significant correlation was shown between those patients with multilevel LSS and the ODI scores; however, significant correlations were not found between the MRI findings and the psychological factors pertaining to sleep and life qualities. PMID:26495059

  3. Hand-assisted versus straight laparoscopic sigmoid colectomy on a training simulator: what is the difference? A stepwise comparison of hand-assisted versus straight laparoscopic sigmoid colectomy performance on an augmented reality simulator.

    LENUS (Irish Health Repository)

    Leblanc, Fabien

    2010-12-01

    We hypothesized that simulator-generated metrics and intraoperative errors may be able to differentiate the technical differences between hand-assisted laparoscopic (HAL) and straight laparoscopic (SL) approaches.

  4. Long-range forces affecting equilibrium inertial focusing behavior in straight high aspect ratio microfluidic channels

    Energy Technology Data Exchange (ETDEWEB)

    Reece, Amy E.; Oakey, John, E-mail: joakey@uwyo.edu [Department of Chemical Engineering, University of Wyoming, Laramie, Wyoming 82071 (United States)

    2016-04-15

    The controlled and directed focusing of particles within flowing fluids is a problem of fundamental and technological significance. Microfluidic inertial focusing provides passive and precise lateral and longitudinal alignment of small particles without the need for external actuation or sheath fluid. The benefits of inertial focusing have quickly enabled the development of miniaturized flow cytometers, size-selective sorting devices, and other high-throughput particle screening tools. Straight channel inertial focusing device design requires knowledge of fluid properties and particle-channel size ratio. Equilibrium behavior of inertially focused particles has been extensively characterized and the constitutive phenomena described by scaling relationships for straight channels of square and rectangular cross section. In concentrated particle suspensions, however, long-range hydrodynamic repulsions give rise to complex particle ordering that, while interesting and potentially useful, can also dramatically diminish the technique’s effectiveness for high-throughput particle handling applications. We have empirically investigated particle focusing behavior within channels of increasing aspect ratio and have identified three scaling regimes that produce varying degrees of geometrical ordering between focused particles. To explore the limits of inertial particle focusing and identify the origins of these long-range interparticle forces, we have explored equilibrium focusing behavior as a function of channel geometry and particle concentration. Experimental results for highly concentrated particle solutions identify equilibrium thresholds for focusing that scale weakly with concentration and strongly with channel geometry. Balancing geometry mediated inertial forces with estimates for interparticle repulsive forces now provide a complete picture of pattern formation among concentrated inertially focused particles and enhance our understanding of the fundamental limits

  5. MORPION: a fast hardware processor for straight line finding in MWPC

    International Nuclear Information System (INIS)

    Mur, M.

    1980-02-01

    A fast hardware processor for straight line finding in MWPC has been built in Saclay and successfully operated in the NA3 experiment at CERN. We give the motivations to build this processor, and describe the hardware implementation of the line finding algorithm. Finally its use and performance in NA3 are described

  6. From MSM to heteroflexibilities: Non-exclusive straight male identities and their implications for HIV prevention and health promotion.

    Science.gov (United States)

    Carrillo, Héctor; Hoffman, Amanda

    2016-01-01

    This article examines the logics of self-identification among men who have same-sex desires and behaviours and consider themselves to be straight. We draw from interviews conducted in the USA with 100 straight-identified men who have same-sex desires and 40 partners of such men. Our data allow us to reject two misconceptions. One is the idea that these men are actually gay or bisexual but refuse to accept those identities. We argue instead that these men see themselves as straight and therefore it is important to understand what specifically they mean by that. The second misconception links straight-identified men who have same-sex desires and behaviours to the racialised discourse of the so-called down low (or 'DL') in the USA. While the DL typically is depicted as involving African American and Latino men, most of our participants are White. Moving beyond these misconceptions, we propose that health educators must acknowledge flexibilities in the definition of heterosexuality and use an expanded definition as a starting point to envision, together with these men, how to more effectively engage them in HIV prevention and health promotion.

  7. SPS RF System Amplifier plant

    CERN Multimedia

    1977-01-01

    The picture shows a 2 MW, 200 MHz amplifier plant with feeder lines. The main RF-system of the SPS comprises four cavities: two of 20 m length and two of 16.5 m length. They are all installed in one long straight section (LSS 3). These cavities are of the travelling-wave type operating at a centre frequency of 200.2 MHz. They are wideband, filling time about 700 ns and untuned. The power amplifiers, using tetrodes are installed in a surface building 200 m from the cavities. Initially only two cavities were installed, a third cavity was installed in 1978 and a forth one in 1979. The number of power amplifiers was also increased: to the first 2 MW plant a second 2 MW plant was added and by end 1979 there were 8 500 kW units combined in pairs to feed each of the 4 cavities with up to about 1 MW RF power, resulting in a total accelerating voltage of about 8 MV. See also 7412016X, 7412017X, 7411048X.

  8. SPS RF Accelerating Cavity

    CERN Multimedia

    1979-01-01

    This picture shows one of the 2 new cavities installed in 1978-1979. The main RF-system of the SPS comprises four cavities: two of 20 m length and two of 16.5 m length. They are all installed in one long straight section (LSS 3). These cavities are of the travelling-wave type operating at a centre frequency of 200.2 MHz. They are wideband, filling time about 700 ns and untuned. The power amplifiers, using tetrodes are installed in a surface building 200 m from the cavities. Initially only two cavities were installed, a third cavity was installed in 1978 and a forth one in 1979. The number of power amplifiers was also increased: to the first 2 MW plant a second 2 MW plant was added and by end 1979 there were 8 500 kW units combined in pairs to feed each of the 4 cavities with up to about 1 MW RF power, resulting in a total accelerating voltage of about 8 MV. See also 7412016X, 7412017X, 7411048X

  9. LS1 Report: the SMACC consolidation train is almost at its destination

    CERN Multimedia

    Simon Baird

    2013-01-01

    At the LHC, the remaining replacement magnets are now installed in their correct positions and awaiting reconnection. The SMACC project continues to advance and three quarters of the interconnect W bellows are now open. In sector 5-6 almost all the SMACC consolidation activities have been completed and the bellows are being closed again ready for testing.   The area around the PSB beam dump. The main part of the SMACC consolidation train is now completing the work on the interconnects in sector 6-7 and starting work in sector 7-8. In the LSS (Long Straight Sections), new equipment is being installed, such as the TCDQs at point 6 and collimators at point 1, and the first kicker at point 8 will be installed in September. The R2E activities at the LHC are also progressing well. At point 5 the new cable ducts have been successfully drilled and the installation of the new safe rooms is in progress. An important milestone was reached in mid-August when the clearance of the magnet transport vehicl...

  10. The Septum Magnet System of the New Fast Extraction Channel of the SPS at CERN

    CERN Document Server

    Balhan, B; Rizzo, A; Weterings, W

    2004-01-01

    In the Long Straight Section LSS4 of the Super Proton Synchrotron (SPS) at CERN, a new fast extraction system has been installed in order to extract the beam to ring 2 of the Large Hadron Collider (LHC) and the CERN Neutrino to Gran Sasso facility (CNGS). The system consists of horizontal closed orbit bumper magnets, extraction kicker magnets, enlarged aperture quadrupoles and six conventional DC electromagnetic septum magnets (MSE). A protection element (TPSG) has been placed immediately upstream of the first septum coil. The septum magnets and TPSG are mounted on a single mobile retractable support girder. The MSE septa are connected by a so-called plug-in system to a rigid water-cooled bus-bar, powered by water-cooled cables. The whole system is kept at the required vacuum pressure by ion pumps attached to separate pumping modules. In this note we present the design features and parameters of the MSE septum magnets, describe the function of the related main equipment elements, briefly report on the control...

  11. LS1 Report: Replacing an antique

    CERN Multimedia

    CERN Bulletin

    2013-01-01

    At the PS Booster, the old beam dump and the shielding blocks surrounding it have been removed (see here). Installation of the new beam dump is now under way (see video).   The new PSB beam dump during its installation. At the PS, replacement of the old cooling and ventilation system, which dated back to 1957, is progressing well. The dismantling phase has just been completed and the tunnel is being prepared to receive a brand new ventilation system offering more efficient aeration of radioactive areas. At the same time, testing of the newly installed access system is under way. At the SPS, all the equipment of the Long Straight Section 1 (LSS1) has been removed to make way for the campaign to replace the irradiated cables, which started this week. In the LHC, the Radiation to Electronics (R2E) campaign is still progressing at a good clip, especially at Point 1, where the teams are two and a half months ahead of schedule. The Superconducting Magnets and Circuits Consolidation (SMACC) proje...

  12. Transient Thermo-Mechanical Analysis of the TPSG4 Beam Diluter

    CERN Document Server

    Goddard, B; Herrera-Martínez, A; Kadi, Y; Marque, S

    2002-01-01

    A new extraction channel is being built in the Super Proton Synchrotron (SPS) Long Straight Section 4 (LSS4) to transfer proton beams to the Large Hadron Collider (LHC) and also to the CERN Neutrino to Gran Sasso (CNGS) target. The beam is extracted in a fast mode during a single turn. For this purpose a protection of the MSE copper septum coil, in the form of a beam diluting element placed upstream, will be required to cope with the new failure modes associated with the fast extraction operation. The present analysis focuses on the thermo-mechanical behavior of the proposed TPSG4 diluter element irradiated by a fast extracted beam (up to 4.9 x 10^13 protons per 7.2 mus pulse) from the SPS. The deposited energy densities, estimated from primary and secondary particle simulations using the high-energy particle transport code FLUKA, were converted to internal heat generation rates taken as a thermal load input for the finite-element engineering analyses code ANSYS. According to the time dependence of the extrac...

  13. Aerodynamic shape optimization of non-straight small wind turbine blades

    International Nuclear Information System (INIS)

    Shen, Xin; Yang, Hong; Chen, Jinge; Zhu, Xiaocheng; Du, Zhaohui

    2016-01-01

    Graphical abstract: Small wind turbine blades with 3D stacking lines (sweep and bend) have been considered and analyzed with an optimization code based on the lifting surface method. The results indicated that the power capture and the rotor thrust can be improved with these more complex geometries. The starting behavior of the small wind turbines can be improved by the optimization of the blade chord and twist angle distribution. - Highlights: • The small wind turbine blade was optimized with non-straight shape. • Lifting surface method with free wake was used for aerodyanmic performace evaluation. • The non-straight shape can be used to increase energy production and decrease the thrust. • The energy production should be sacrificed in order to increase the starting behavior. - Abstract: Small wind turbines usually operate in sub-optimal wind conditions in order to satisfy the demand where it is needed. The aerodynamic performance of small horizontal axis wind turbines highly depends on the geometry. In the present study, the geometry of wind turbine blades are optimized not only in terms of the distribution of the chord and twist angle but also with 3-dimensional stacking line. As the blade with 3-dimensional stacking line is given sweep in the plan of rotation and dihedral in the plan containing the blade and rotor axis, the common used blade element momentum method can no longer provide accurate aerodynamic performance solution. A lifting surface method with free wake model is used as the aerodynamic model in the present work. The annual energy production and the starting performance are selected as optimization objective. The starting performance is evaluated based on blade element method. The optimization of the geometry of the non-straight wind turbine blades is carried out by using a micro-genetic algorithm. Results show that the wind turbine blades with properly designed 3-dimensional stacking line can increase the annual energy production and have

  14. Unzip instabilities: Straight to oscillatory transitions in the cutting of thin polymer sheets

    Science.gov (United States)

    Reis, P. M.; Kumar, A.; Shattuck, M. D.; Roman, B.

    2008-06-01

    We report an experimental investigation of the cutting of a thin brittle polymer sheet with a blunt tool. It was recently shown that the fracture path becomes oscillatory when the tool is much wider than the sheet thickness. Here we uncover two novel transitions from straight to oscillatory fracture by varying either the tilt angle of the tool or the speed of cutting, respectively. We denote these by angle and speed unzip instabilities and analyze them by quantifying both the dynamics of the crack tip and the final shapes of the fracture paths. Moreover, for the speed unzip instability, the straight crack lip obtained at low speeds exhibits out-of-plane buckling undulations (as opposed to being flat above the instability threshold) suggesting a transition from ductile to brittle fracture.

  15. Analysis of a Steerable Needle for Fine Needle Aspiration and Biopsy: Efficiency and Radiation Dose Compared With a Conventional Straight Needle.

    Science.gov (United States)

    Rutigliano, Sandra; Abraham, John A; Kenneally, Barry E; Zoga, Adam C; Nevalainen, Mika; Roedl, Johannes B

    Percutaneous computed tomography (CT)-guided needle biopsy has proven to be an efficacious method for sampling of many soft tissue lesions, especially deep-seated masses in the abdomen and pelvis. This study sought to test the potential for a novel steerable needle to improve localization and to reduce procedure duration and radiation dose compared with a conventional straight needle. A fresh, raw meat sample (lean bovine flank) was imbedded with cylindrical radiopaque and radiolucent obstacles designed to simulate vessels (radiolucent objects) and bones (radiopaque objects) on CT. A pit-containing olive (partially radiopaque) was imbedded beyond the obstacles to represent the target. Two sites on the surface of the meat were selected and marked to determine initial needle placement. Two radiologists with different levels of experience proceeded to position a straight needle and the steerable needle from each skin site to the target using CT guidance as efficiently as possible, avoiding the obstacles. The total positioning time, the number of CT scans required for positioning, and the number of repositioning events (partial withdrawal followed by advancement) were tracked for the straight and steerable needles. For the straight needle, total time to reach the target was 499 to 667 seconds (mean, 592 seconds); for the steerable needle, total time to reach the target was 281 to 343 seconds (mean, 309 seconds), on average, 48% lower. The number of CT scans needed for needle positioning averaged 6.25 for the straight needle and 3.5 for the steerable needle, which is 44% lower. Repositioning events (withdrawing and readvancing the needle) ranged from 3 to 10 for the straight needle (mean, 6.5) and 0 for the steerable needle. Using an in vitro model embedded with obstacles, the steerable needle performed better than a straight needle with regard to procedure time, needle repositioning events, and CT scans required for placement.

  16. Straight A's: Public Education Policy and Progress. Volume 12, Number 7

    Science.gov (United States)

    Amos, Jason, Ed.

    2012-01-01

    "Straight A's: Public Education Policy and Progress" is a biweekly newsletter that focuses on education news and events both in Washington, DC and around the country. The following articles are included in this issue: (1) Problems Down the Road: House Passes Congressional Budget Resolutions, Sets Overall Spending Cap at $19 Billion Below Senate;…

  17. A Program Review of a Middle School Gay-Straight Alliance Club

    Science.gov (United States)

    Quasha, Scott; McCabe, Paul C.; Ortiz, Samuel O.

    2014-01-01

    This program review examined a middle school Gay-Straight Alliance (GSA) club within a northeastern suburban school situated in a large metropolitan area. The GSA was the first in the region to start exclusively in a standalone middle school. The review was accomplished through a staff survey comparing school climates for lesbian, gay, bisexual,…

  18. Straight A's: Public Education Policy and Progress. Volume 6, Number 2

    Science.gov (United States)

    Amos, Jason, Ed.

    2006-01-01

    "Straight A's: Public Education Policy and Progress" is a biweekly newsletter that focuses on education news and events both in Washington, DC and around the country. The following articles are included in this issue: (1) State of American Business: U.S. Chamber of Commerce Says U.S. Could Face a "Severe Worker Shortage" Unless…

  19. Parallel Hough Transform-Based Straight Line Detection and Its FPGA Implementation in Embedded Vision

    Directory of Open Access Journals (Sweden)

    Nam Ling

    2013-07-01

    Full Text Available Hough Transform has been widely used for straight line detection in low-definition and still images, but it suffers from execution time and resource requirements. Field Programmable Gate Arrays (FPGA provide a competitive alternative for hardware acceleration to reap tremendous computing performance. In this paper, we propose a novel parallel Hough Transform (PHT and FPGA architecture-associated framework for real-time straight line detection in high-definition videos. A resource-optimized Canny edge detection method with enhanced non-maximum suppression conditions is presented to suppress most possible false edges and obtain more accurate candidate edge pixels for subsequent accelerated computation. Then, a novel PHT algorithm exploiting spatial angle-level parallelism is proposed to upgrade computational accuracy by improving the minimum computational step. Moreover, the FPGA based multi-level pipelined PHT architecture optimized by spatial parallelism ensures real-time computation for 1,024 × 768 resolution videos without any off-chip memory consumption. This framework is evaluated on ALTERA DE2-115 FPGA evaluation platform at a maximum frequency of 200 MHz, and it can calculate straight line parameters in 15.59 ms on the average for one frame. Qualitative and quantitative evaluation results have validated the system performance regarding data throughput, memory bandwidth, resource, speed and robustness.

  20. Parallel Hough Transform-based straight line detection and its FPGA implementation in embedded vision.

    Science.gov (United States)

    Lu, Xiaofeng; Song, Li; Shen, Sumin; He, Kang; Yu, Songyu; Ling, Nam

    2013-07-17

    Hough Transform has been widely used for straight line detection in low-definition and still images, but it suffers from execution time and resource requirements. Field Programmable Gate Arrays (FPGA) provide a competitive alternative for hardware acceleration to reap tremendous computing performance. In this paper, we propose a novel parallel Hough Transform (PHT) and FPGA architecture-associated framework for real-time straight line detection in high-definition videos. A resource-optimized Canny edge detection method with enhanced non-maximum suppression conditions is presented to suppress most possible false edges and obtain more accurate candidate edge pixels for subsequent accelerated computation. Then, a novel PHT algorithm exploiting spatial angle-level parallelism is proposed to upgrade computational accuracy by improving the minimum computational step. Moreover, the FPGA based multi-level pipelined PHT architecture optimized by spatial parallelism ensures real-time computation for 1,024 × 768 resolution videos without any off-chip memory consumption. This framework is evaluated on ALTERA DE2-115 FPGA evaluation platform at a maximum frequency of 200 MHz, and it can calculate straight line parameters in 15.59 ms on the average for one frame. Qualitative and quantitative evaluation results have validated the system performance regarding data throughput, memory bandwidth, resource, speed and robustness.

  1. Optimization of Straight Cylindrical Turning Using Artificial Bee Colony (ABC) Algorithm

    Science.gov (United States)

    Prasanth, Rajanampalli Seshasai Srinivasa; Hans Raj, Kandikonda

    2017-04-01

    Artificial bee colony (ABC) algorithm, that mimics the intelligent foraging behavior of honey bees, is increasingly gaining acceptance in the field of process optimization, as it is capable of handling nonlinearity, complexity and uncertainty. Straight cylindrical turning is a complex and nonlinear machining process which involves the selection of appropriate cutting parameters that affect the quality of the workpiece. This paper presents the estimation of optimal cutting parameters of the straight cylindrical turning process using the ABC algorithm. The ABC algorithm is first tested on four benchmark problems of numerical optimization and its performance is compared with genetic algorithm (GA) and ant colony optimization (ACO) algorithm. Results indicate that, the rate of convergence of ABC algorithm is better than GA and ACO. Then, the ABC algorithm is used to predict optimal cutting parameters such as cutting speed, feed rate, depth of cut and tool nose radius to achieve good surface finish. Results indicate that, the ABC algorithm estimated a comparable surface finish when compared with real coded genetic algorithm and differential evolution algorithm.

  2. Straight A's: Public Education Policy and Progress. Volume 12, Number 9

    Science.gov (United States)

    Amos, Jason, Ed.

    2012-01-01

    "Straight A's: Public Education Policy and Progress" is a biweekly newsletter that focuses on education news and events both in Washington, DC and around the country. The following articles are included in this issue: (1) You Take the High Road and I'll Take the Low Road: As Appropriations Process Begins, Different Spending Approaches Likely to…

  3. Dynamic mechanical properties of straight titanium alloy arch wires.

    Science.gov (United States)

    Kusy, R P; Wilson, T W

    1990-10-01

    Eight straight-wire materials were studied: an orthodontic titanium-molybdenum (Ti-Mo) product, TMA; three orthodontic nickel-titanium (Ni-Ti) products, Nitinol, Titanal, and Orthonol; three prototype alloys, a martensitic, an austenitic, and a biphasic alloy; and a hybrid shape-memory-effect product, Biometal. Each wire was prepared with a length-to-cross-sectional area of at least 3600 cm-1. With an Autovibron Model DDV-II-C used in the tensile mode, each sample was scanned from -120 to +200 degrees C at 2 degrees C/min. From the data base, plots of the log storage modulus, log tan delta, and percent change in length vs. temperature were generated. Results showed that the dynamic mechanical properties of the alloys within this TI system are quite different. The Ti-Mo alloy, TMA, was invariant with temperature, having a modulus of 7.30 x 10(11) dyne/cm2 (10.6 x 10(6) psi). The three cold-worked alloys--Nitinol, Titanal, and Orthonol--appeared to be similar, having a modulus of 5.74 x 10(11) dyne/cm2 (8.32 x 10(6) psi). The biphasic shape-memory alloy displayed a phase transformation near ambient temperature; whereas the hybrid shape-memory product, Biometal, underwent a 3-5% change in length during its transformation between 95 and 125 degrees C. Among the Ni-Ti wires tested, several different types of alloys were represented by this intermetallic material.

  4. The female geriatric proximal humeral fracture: protagonist for straight antegrade nailing?

    Science.gov (United States)

    Lindtner, Richard A; Kralinger, Franz S; Kapferer, Sebastian; Hengg, Clemens; Wambacher, Markus; Euler, Simon A

    2017-10-01

    Straight antegrade humeral nailing (SAHN) has become a standard technique for the surgical fixation of proximal humeral fractures, which predominantly affect elderly females. The nail's proximal anchoring point has been demonstrated to be critical to ensure reliable fixation in osteoporotic bone and to prevent iatrogenic damage to the superior rotator cuff bony insertion. Anatomical variations of the proximal humerus, however, may preclude satisfactory anchoring of the nail's proximal end and may bare the risk of rotator cuff violation, even though the nail is inserted as recommended. The aim of this study was to evaluate the anatomical suitability of proximal humeri of geriatric females aged 75 years and older for SAHN. Specifically, we sought to assess the proportion of humeri not anatomically amenable to SAHN for proximal humeral fracture. A total of 303 proximal humeri of 241 females aged 75 years and older (mean age 84.5 ± 5.0 years; range 75-102 years) were analyzed for this study. Multiplanar two-dimensional reformations (true ap, true lateral, and axial) were reconstructed from shoulder computed tomography (CT) data sets. The straight antegrade nail's ideal entry point, "critical point" (CP), and critical distance (CD; distance between ideal entry point and CP) were determined. The rate of proximal humeri not anatomically suitable for SAHN (critical type) was assessed regarding proximal reaming diameters of currently available straight antegrade humeral nails. Overall, 35.6% (108/303) of all proximal humeri were found to be "critical types" (CD straight antegrade nails currently in use. Moreover, 43.2% (131/303) of the humeri were considered "critical types" with regard to the alternatively used larger proximal reaming diameter of 11.5 mm. Mean CD was 9.0 ± 1.7 mm (range 3.5-13.5 mm) and did not correlate with age (r = -0.04, P = 0.54). No significant differences in CD and rate of "critical types" were found between left and right humeri

  5. Numerical investigation on the flow and power of small-sized multi-bladed straight Darrieus wind turbine

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Straight Darrieus wind turbine has attractive characteristics such as the ability to accept wind from random direction and easy installation and maintenance. But its aerodynamic performance is very complicated, especially for the existence of dynamic stall. How to get better aerodynamic performance arouses lots of interests in the design procedure of a straight Darrieus wind turbine. In this paper, mainly the effects of number of blades and tip speed ratio are discussed. Based on the numerical investigation, an assumed asymmetric straight Darrieus wind turbine is proposed to improve the averaged power coefficient. As to the numerical method, the flow around the turbine is simulated by solving the 2D unsteady Navier-Stokes equation combined with continuous equation. The time marching method on a body-fitted coordinate system based on MAC (Marker-and-Cell) method is used. O-type grid is generated for the whole calculation domain. The characteristics of tangential and normal force are discussed related with dynamic stall of the blade. Averaged power coefficient per period of rotating is calculated to evaluate the eligibility of the turbine.

  6. Movement of the sacroiliac joint during the Active Straight Leg Raise test in patients with long-lasting severe sacroiliac joint pain.

    Science.gov (United States)

    Kibsgård, Thomas J; Röhrl, Stephan M; Røise, Olav; Sturesson, Bengt; Stuge, Britt

    2017-08-01

    The Active Straight Leg Raise is a functional test used in the assessment of pelvic girdle pain, and has shown to have good validity, reliability and responsiveness. The Active Straight Leg Raise is considered to examine the patients' ability to transfer load through the pelvis. It has been hypothesized that patients with pelvic girdle pain lack the ability to stabilize the pelvic girdle, probably due to instability or increased movement of the sacroiliac joint. This study examines the movement of the sacroiliac joints during the Active Straight Leg Raise in patients with pelvic girdle pain. Tantalum markers were inserted in the dorsal sacrum and ilium of 12 patients with long-lasting pelvic girdle pain scheduled for sacroiliac joint fusion surgery. Two to three weeks later movement of the sacroiliac joints during the Active Straight Leg Raise was measured with radiostereometric analysis. Small movements were detected. There was larger movement of the sacroiliac joint of the rested leg's sacroiliac joint compared to the lifted leg's side. A mean backward rotation of 0.8° and inward tilt of 0.3° were seen in the rested leg's sacroiliac joint. The movements of the sacroiliac joints during the Active Straight Leg Raise are small. There was a small backward rotation of the innominate bone relative to sacrum on the rested leg's side. Our findings contradict an earlier understanding that a forward rotation of the lifted leg's innominate occur while performing the Active Straight Leg Raise. Copyright © 2017. Published by Elsevier Ltd.

  7. High School Gay-Straight Alliances (GSAs) and Young Adult Well-Being: An Examination of GSA Presence, Participation, and Perceived Effectiveness

    Science.gov (United States)

    Toomey, Russell B.; Ryan, Caitlin; Diaz, Rafael M.; Russell, Stephen T.

    2011-01-01

    Gay-Straight Alliances (GSAs) are student-led, school-based clubs that aim to provide a safe environment in the school context for lesbian, gay, bisexual, and transgender (LGBT) students, as well as their straight allies. The present study examines the potential for GSAs to support positive youth development and to reduce associations among…

  8. Straight Ahead in Microgravity

    Science.gov (United States)

    Wood, S. J.; Vanya, R. D.; Clement, G.

    2014-01-01

    This joint ESA-NASA study will address adaptive changes in spatial orientation related to the subjective straight ahead, and the use of a vibrotactile sensory aid to reduce perceptual errors. The study will be conducted before and after long-duration expeditions to the International Space Station (ISS) to examine how spatial processing of target location is altered following exposure to microgravity. This project specifically addresses the sensorimotor research gap "What are the changes in sensorimotor function over the course of a mission?" Six ISS crewmembers will be requested to participate in three preflight sessions (between 120 and 60 days prior to launch) and then three postflight sessions on R+0/1 day, R+4 +/-2 days, and R+8 +/-2 days. The three specific aims include: (a) fixation of actual and imagined target locations at different distances; (b) directed eye and arm movements along different spatial reference frames; and (c) the vestibulo-ocular reflex during translation motion with fixation targets at different distances. These measures will be compared between upright and tilted conditions. Measures will then be compared with and without a vibrotactile sensory aid that indicates how far one has tilted relative to the straight-ahead direction. The flight study was been approved by the medical review boards and will be implemented in the upcoming Informed Crew Briefings to solicit flight subject participation. Preliminary data has been recorded on 6 subjects during parabolic flight to examine the spatial coding of eye movements during roll tilt relative to perceived orientations while free-floating during the microgravity phase of parabolic flight or during head tilt in normal gravity. Binocular videographic recordings obtained in darkness allowed us to quantify the mean deviations in gaze trajectories along both horizontal and vertical coordinates relative to the aircraft and head orientations. During some parabolas, a vibrotactile sensory aid provided

  9. Penerapan Metode Straight Selection pada Sistem Parkir Universitas Bina Nusantara

    OpenAIRE

    Maharani, Mega; Merlina, Nita

    2014-01-01

    The parking information System is designed to develop the current system that has been employed at BINA NUSANTARA University. Currently, the parking system is limited only recording the police number and they are still manually looking for the available parking area. The system implements straight selection sorting data method, also known as the smallest number search method to determine the available parking location. Parking area will be automatically printed at parking ticket, thus the dri...

  10. Advantages of Direct Insertion of a Straight Probe Without a Guide Tube During Anterior Odontoid Screw Fixation of Odontoid Fractures.

    Science.gov (United States)

    Park, Jin Hoon; Kang, Dong-Ho; Lee, Moon Kyu; Yoo, Byoungwoo; Jung, Sang Ku; Hwang, Soo-Hyun; Kim, Jeoung Hee; Oh, Sunkyu; Lee, Eun Jung; Jeon, Sang Ryong; Roh, Sung Woo; Rhim, Seung Chul

    2016-05-01

    A retrospective cohort study. The aim of this study was to compare the anterior odontoid screw fixation (AOSF) with a guide tube or with a straight probe. AOSF associates with several complications, including malpositioning, fixation loss, and screw breakage. Screw pull-out from the C2 body is the most common complication. All consecutive patients with type II or rostral shallow type III odontoid fractures who underwent AOSFs during the study period were enrolled retrospectively. The guide-tube AOSF method followed the standard published method except C3 body and C2-3 disc annulus rimming was omitted to prevent disc injury; instead, the guide tube was anchored at the anterior inferior C2 vertebra corner. After 2 screw pull-outs, the guide-tube cohort was analyzed to identify the cause of instrument failure. Thereafter, the straight-probe method was developed. A guide tube was not used. A small pilot hole was made on the most anterior side of the inferior endplate, followed by insertion of a 2.5 mm straight probe through the C2 body. Non-union and instrument failure rates and screw-direction angles of the guide-tube and straight-probe groups were recorded. The guide-tube group (n = 13) had 2 screw pull-outs and 1 non-union. The straight-probe group (n = 8) had no complications and significantly larger screw-direction angles than the guide-tube group (60.5 ± 4.63 vs. 54.8 ± 3.82 degrees; P = 0.047). Straight-probe AOSF yielded larger direction angles without injuring bone and disc. Complications were absent. The procedure was easier than guide-tube AOSF and assured sufficient engagement, even in horizontal fracture orientation cases. 3.

  11. Straight vegetable oil use in Micro-Gas Turbines: System adaptation and testing

    International Nuclear Information System (INIS)

    Prussi, M.; Chiaramonti, D.; Riccio, G.; Martelli, F.; Pari, L.

    2012-01-01

    Highlights: → The possibility to feed a Micro Gas Turbine with Straight Vegetable Oil (SVO) has been investigated. → Correlative analysis and CFD were used to model the effect of SVO characteristics on atomization and evaporation. → Minor modifications to a the commercial MGT were adopted. → Measured power output and specific fuel consumption were close to standard fuel, taking into account the LHV of SVO. → Emissions were higher than for standard fossil fuel but strongly affected by SVO temperature. -- Abstract: The aim of this research work is to investigate the use of straight vegetable sunflower oil (SFO), a liquid biofuel, in a Micro-Gas Turbine (MGT). Compared to conventional diesel engines, micro-gas turbines represent a very reliable, clean and performing small scale cogeneration technology. Commercial gas turbines have already been tested with unconventional fuels, such as biomass derived fuels; however, research work on using Straight Vegetable Oil (SVO) as fuel in MGTs are really scarce. The chemical and physical characteristics of SVO are different from fossil diesel oil and rather far from the common technical specifications for gas turbine liquid fuels, not only in terms of kinematic viscosity and Lower Heating Value, but also as regards other issues as contaminant levels and composition, fuel cold properties, ignition properties, etc. Therefore, particular attention has to be given to the atomization and evaporation phases, as these are the most critical steps to achieve stable and efficient long term operation. An analysis based on numerical correlations available from literature was initially adopted for the analysis of the atomization process, supported by CFD modeling to qualitatively investigate the flow pattern. Control parameters were revised and set so to produce a sunflower oil spray having evaporation time comparable to diesel, and minor adaptations to the fuel line were designed and installed on the MGT. Tests with blends and

  12. "Not Going Away": Approaches Used by Students, Faculty, and Staff Members to Create Gay-Straight Alliances at Three Religiously Affiliated Universities

    Science.gov (United States)

    McEntarfer, Heather Killelea

    2011-01-01

    This qualitative study examines the processes of forming gay-straight alliances at three religiously affiliated institutions of higher education. Using the lens of Social Movement Theory (SMT), this paper presents the methods and approaches used when advocates of gay-straight alliances at these institutions encountered resistance from…

  13. Straight-bladed Darrieus wind turbines - A protagonist's view

    Science.gov (United States)

    Migliore, P. G.

    The technology development and market penetration of Darrieus and propeller-type wind turbines is addressed. Important characteristics of competing configurations are compared, and it is claimed that aerodynamic efficiency is not a distinguishing feature. Advantages of the Darrieus machine include omni-directionality and self-limitation, but propeller types require less rotor length per unit swept area. It is argued that the straight-bladed Darrieus is much simpler than the curved-bladed and should be capable of comparable aerodynamic efficiency. Some of the problems of structural design, as well as blade induced drag losses and support-arm counter torque, diminish rapidly as machine size is increased. Taper ratio has similar beneficial effects.

  14. Evaluating the Subjective Straight Ahead Before and After Spaceflight

    Science.gov (United States)

    Campbell, D. J.; Wood, S. J.; Reschke, M. F.; Clement, G.

    2017-01-01

    This joint European Space Agency (ESA) - NASA study will address adaptive changes in spatial orientation related to the subjective straight ahead and the use of a vibrotactile sensory aid to reduce perceptual errors. The study will be conducted before and after long duration expeditions to the International Space Station (ISS) to examine how spatial processing of target location is altered following exposure to microgravity. This study addresses the sensorimotor research gap to "determine the changes in sensorimotor function over the course of a mission and during recovery after landing."

  15. Evaluation of the predictive capacity of DNA variants associated with straight hair in Europeans.

    Science.gov (United States)

    Pośpiech, Ewelina; Karłowska-Pik, Joanna; Marcińska, Magdalena; Abidi, Sarah; Andersen, Jeppe Dyrberg; Berge, Margreet van den; Carracedo, Ángel; Eduardoff, Mayra; Freire-Aradas, Ana; Morling, Niels; Sijen, Titia; Skowron, Małgorzata; Söchtig, Jens; Syndercombe-Court, Denise; Weiler, Natalie; Schneider, Peter M; Ballard, David; Børsting, Claus; Parson, Walther; Phillips, Chris; Branicki, Wojciech

    2015-11-01

    DNA-based prediction of hair morphology, defined as straight, curly or wavy hair, could contribute to an improved description of an unknown offender and allow more accurate forensic reconstructions of physical appearance in the field of forensic DNA phenotyping. Differences in scalp hair morphology are significant at the worldwide scale and within Europe. The only genome-wide association study made to date revealed the Trichohyalin gene (TCHH) to be significantly associated with hair morphology in Europeans and reported weaker associations for WNT10A and FRAS1 genes. We conducted a study that centered on six SNPs located in these three genes with a sample of 528 individuals from Poland. The predictive capacity of the candidate DNA variants was evaluated using logistic regression; classification and regression trees; and neural networks, by applying a 10-fold cross validation procedure. Additionally, an independent test set of 142 males from six European populations was used to verify performance of the developed prediction models. Our study confirmed association of rs11803731 (TCHH), rs7349332 (WNT10A) and rs1268789 (FRAS1) SNPs with hair morphology. The combined genotype risk score for straight hair had an odds ratio of 2.7 and these predictors explained ∼ 8.2% of the total variance. The selected three SNPs were found to predict straight hair with a high sensitivity but low specificity when a 10-fold cross validation procedure was applied and the best results were obtained using the neural networks approach (AUC=0.688, sensitivity=91.2%, specificity=23.0%). Application of the neural networks model with 65% probability threshold on an additional test set gave high sensitivity (81.4%) and improved specificity (50.0%) with a total of 78.7% correct calls, but a high non-classification rate (66.9%). The combined TTGGGG SNP genotype for rs11803731, rs7349332, rs1268789 (European frequency=4.5%) of all six straight hair-associated alleles was identified as the best

  16. Conversion of straight-run gas-condensate benzenes into high- octane gasolines based on modified ZSM-5 zeolites

    International Nuclear Information System (INIS)

    Erofeev, V; Reschetilowski, V; Khomajakov, I; Egorova, L; Volgina, T; Tatarkina, A

    2014-01-01

    This paper describes the conversion of straight-run benzene of gas condensate into high-octane gasoline based on zeolite catalyst ZSM-5, modified in binary system oxide- based Sn (III) and Bi (III). It was defined that the introduction of the binary system oxide-based Sn(III) and Bi (III) into the basic zeolite results in the 2-fold increase of its catalytic activity.High-octane gasoline converted from straight-run benzene is characterized by a low benzol content in comparison to the high-octane benzenes produced during the catalytic reforming

  17. A novel low-temperature chemical solution route for straight and dendrite-like ZnO nanostructures

    International Nuclear Information System (INIS)

    Zhang Hui; Du Ning; Wu Jianbo; Ma, Xiangyang; Yang Deren; Zhang Xiaobin; Yang Zhiqing

    2007-01-01

    The straight and dendrite-like growths of ZnO have been completely and simply controlled by the status of ZnO seed instead of surfactant, template, oriented attachment, and ZnO buffer layer on the substrate in the chemical reaction synthesis of ZnO nanostructures. The monodisperse ZnO seeds, which are prepared by in situ quickly injecting the cool mixed zinc acetate and potassium hydrate ethanol solution into the hot matrix aqueous solution of zinc nitrate hydrate and diethylenetriamine at 95 deg. C, improve the straight growth and lots of uniform, straight, and single-crystalline ZnO nanorods with about 20-30 nm in diameter and 300 nm in length are achieved. While, the aggregated ZnO seeds, which are prepared by dropwise adding potassium hydrate ethanol solution into zinc acetate ethanol solution at 60 deg. C for 3 h, result in the dendrite-like growth and the bur-like ZnO nanostructures consisting of hundreds of nanorods with about 30-50 nm in diameter and several micrometers in length are formed. Furthermore, the approach presented here provides a simple, low-cost, environmental-friendly and high efficiency route to synthesize the high quality ZnO nanorods and bur-like ZnO nanostructures

  18. Features of vertical axis wind turbine and development of airfoils sections; Chokusen yokugata suichoku jiku fusha no tokucho to yokugata ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Seki, K; Shimizu, Y; Yasui, T [Tokai University, Tokyo (Japan); Nakayama, H [Oriental Kiden Company, Osaka (Japan)

    1996-10-27

    Features of a straight wing type vertical axis wind turbine (VAW) and its airfoil sections were studied. The wind turbine in which various aerodynamic work components are mounted on the rotation axis normal to the ground surface is named VAW. Like the airfoil section of aircraft, in lift type VAW, wind turbines were driven by lift 70-90 times as large as drag in some cases. Features of the VAW airfoil section which is a straight wing in plan and a fixed pitch wing (with a fixed angle to a blade support arm) in cross section, and those of wind turbines were studied. Some factors affecting the features, work principle and performance of VAW were clarified. On airfoil sections, products of each weight function and each corresponding aerodynamic factor (lift, drag and pitching moment factors) were plotted on an attack angle ({alpha}) axis. From the conditions for increasing the total sum of areas drawn by the products on the {alpha} axis, various characteristics required for airfoil sections were clarified. Such characteristics nearly agreed between an airfoil section for favorable starting characteristics and that for high efficiency. 3 refs., 7 figs.

  19. Real-Time Straight-Line Detection for XGA-Size Videos by Hough Transform with Parallelized Voting Procedures.

    Science.gov (United States)

    Guan, Jungang; An, Fengwei; Zhang, Xiangyu; Chen, Lei; Mattausch, Hans Jürgen

    2017-01-30

    The Hough Transform (HT) is a method for extracting straight lines from an edge image. The main limitations of the HT for usage in actual applications are computation time and storage requirements. This paper reports a hardware architecture for HT implementation on a Field Programmable Gate Array (FPGA) with parallelized voting procedure. The 2-dimensional accumulator array, namely the Hough space in parametric form (ρ, θ), for computing the strength of each line by a voting mechanism is mapped on a 1-dimensional array with regular increments of θ. Then, this Hough space is divided into a number of parallel parts. The computation of (ρ, θ) for the edge pixels and the voting procedure for straight-line determination are therefore executable in parallel. In addition, a synchronized initialization for the Hough space further increases the speed of straight-line detection, so that XGA video processing becomes possible. The designed prototype system has been synthesized on a DE4 platform with a Stratix-IV FPGA device. In the application of road-lane detection, the average processing speed of this HT implementation is 5.4ms per XGA-frame at 200 MHz working frequency.

  20. The impact of subsidence on straight and curved modular cementless revision stems in hip revision surgery.

    Science.gov (United States)

    Fraile Suari, A; Gil González, S; Pérez Prieto, D; León García, A; Mestre Cortadellas, C; Tey Pons, M; Marqués López, F

    Subsidence is one of the potential complications in femoral stem revision total hip arthroplasty surgery, and can affect stability and osseointegration. A retrospective study was conducted on the outcomes at one year and 5 years (specifically subsidence and clinical relevance) of 40 consecutive femoral total hip arthroplasty revisions, comparing two modular cementless revision stems, Straight vs. Curved, with 20 patients in each group. No mechanical failure was observed, and there was an improvement in functional outcomes. Mean radiological subsidence was 9.9±4.9mm (straight=10.75mm vs. curved=9.03mm), with no statistically significant difference between groups (p=0,076). Fourteen patients (35%) had ≥10mm of subsidence, up to a maximum of 22mm. The subsidence found in this study is similar to published series, with no short-term clinical manifestations, or an increased number of complications or stem loosening in either the Straight or Curved group. No differences in subsidence were observed at one year and 5 years after surgery between the 2 types of stems. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. The GSA Difference: LGBTQ and Ally Experiences in High Schools with and without Gay-Straight Alliances

    Directory of Open Access Journals (Sweden)

    Tina Fetner

    2015-08-01

    Full Text Available We examine the lived experiences of high-school students who participated in lesbian, gay, bisexual, transgender, and queer (LGBTQ-centered activism of some kind, highlighting the promise of gay-straight alliance groups by comparing the experiences of students at schools with gay-straight alliances (GSA schools with the experiences of students at schools that did not have an LGBTQ-specific group (no-GSA schools. We compare students at GSA and no-GSA schools based on their experiences of harassment, experiences of support from authority figures, and patterns of friendships. We find that students at both types of schools experienced harassment and heard negative comments about lesbian and gay people. However, students at GSA schools reported more support from teachers and administrators than students at no-GSA schools, who have stories of teachers and administrators actively opposing equality for LGBTQ people. Students at GSA schools reported a wide variety of friendships across sexual identities, while students at no-GSA schools felt more isolated and withdrawn. This much-needed qualitative comparative analysis of students’ experiences brings a human face to the improved quality of life that schools with gay-straight alliances can bring to young people.

  2. The distribution characteristics of pollutants released at different cross-sectional positions of a river

    International Nuclear Information System (INIS)

    Huang Heqing; Chen Guang; Zhang Qianfeng

    2010-01-01

    The distribution characteristics of heavier or lighter pollutants released at different cross-sectional positions of a wide river is investigated with a well-tested three-dimensional numerical model of gravity flows based on Reynolds-Averaged Navier-Stokes equations and turbulence k-ε model. By focusing on investigating the influences of flow and buoyancy on pollutants, it is found that while carrying by the river flow downstream: i) a heavier pollutant released from the cross-sectional side position, forms transverse oscillation between two banks with decreased amplitude, i.e. forms kind of helical flow pattern along the straight part of channel bed; ii) a heavier pollutant released from the cross-sectional middle position, forms collapse oscillation in the middle of the straight channel part with reduced amplitude; iii) in the downstream sinuous channel, heavier pollutant is of higher concentration on the outer side of channel bends; iv) a light pollutant released from the cross-sectional side position, slips partly to the other side of the river, resulting in higher concentrations on two sides of the channel top; v) a light pollutant released from the cross-sectional middle position, splits into two parts symmetrically along two sides of the channel top; vi) in the downstream sinuous channel, light pollutant presents higher concentration on the inner side of channel bends. These findings may assist in cost-effective scientific countermeasures to be taken for accidental or planned pollutant releases into a river. - The distribution characteristics of heavier or lighter pollutants released at different cross-sectional positions of a river.

  3. A potential flow 2-D vortex panel model: Applications to vertical axis straight blade tidal turbine

    International Nuclear Information System (INIS)

    Wang, L.B.; Zhang, L.; Zeng, N.D.

    2007-01-01

    A potential flow 2-D vortex panel model (VPM2D) for unsteady hydrodynamics calculation of the vertical axis straight blade variable pitch turbine was given for tidal streams energy conversion. Numerical results of predicted instantaneous blade forces and wake flow of the rotor showed good agreement with the test data. The model was also compared with the previous classic free vortex model (V-DART) and vortex method combined with finite element analysis (FEVDTM). It showed that the present model was much better than the former, less complex than the latter and suitable for designing and optimization of the vertical axis straight blade turbine

  4. A comparison of a 'J' wire and a straight wire in successful antegrade cannulation of the superficial femoral artery

    International Nuclear Information System (INIS)

    Gay, D.A.T.; Edwards, A.J.; Puckett, M.A.; Roobottom, C.A.

    2005-01-01

    AIMS: To evaluate the success of two different types of wire in common use in their ability to successfully cannulate the superficial femoral artery (SFA) using antegrade puncture. METHODS: 50 consecutive patients in whom antegrade infra-inguinal intervention was planned, underwent common femoral arterial puncture and then cannulation with either a standard 3 mm 'J' wire or a floppy tipped straight wire (William Cook--Europe). The frequency with which each type of wire entered the SFA or profunda femoris artery without image guidance was recorded. Further analysis was also made of the success of manipulation of the wire into the SFA following profunda cannulation and the use of alternative guide wires. RESULTS: In 19 out of 25 (76%) patients the 'J' wire correctly entered the SFA without image guidance. Only 5 out of 25 (25%) of straight wires entered the SFA with the initial pass (p<0.0001). Following further manipulation with the same wire all except 1 'J' wire was successfully negotiated into the SFA. The same was true for only 9 of the remaining straight wires with 11 patients requiring an alternative guide wire. CONCLUSIONS: When performing antegrade cannulation of the SFA a 'J' wire is more likely to be successful than a straight guide wire

  5. Determining shapes and dimensions of dental arches for the use of straight-wire arches in lingual technique.

    Science.gov (United States)

    Kairalla, Silvana Allegrini; Scuzzo, Giuseppe; Triviño, Tarcila; Velasco, Leandro; Lombardo, Luca; Paranhos, Luiz Renato

    2014-01-01

    This study aims to determine the shape and dimension of dental arches from a lingual perspective, and determine shape and size of a straight archwire used for lingual Orthodontics. The study sample comprised 70 Caucasian Brazilian individuals with normal occlusion and at least four of Andrew's six keys. Maxillary and mandibular dental casts were digitized (3D) and the images were analyzed by Delcam Power SHAPET 2010 software. Landmarks on the lingual surface of teeth were selected and 14 measurements were calculated to determine the shape and size of dental arches. Shapiro-Wilk test determined small arch shape by means of 25th percentile (P25%)--an average percentile for the medium arch; and a large one determined by means of 75th percentile (P75%). T-test revealed differences between males and females in the size of 12 dental arches. The straight-wire arch shape used in the lingual straight wire technique is a parabolic-shaped arch, slightly flattened on its anterior portion. Due to similarity among dental arch sizes shown by males and females, a more simplified diagram chart was designed.

  6. Straight-line assimilation in home-leaving? A comparison of Turks, Somalis and Danes

    DEFF Research Database (Denmark)

    Nielsen, Rikke Skovgaard

    2016-01-01

    The purpose of this paper is to test the evidence for spatial assimilation and straight-line assimilation in the transition of leaving home in Denmark. Based on data from the extensive Danish registers, the paper analyses the home-leaving patterns of Danes, Turkish immigrants, Turkish descendants...

  7. Effect of Ankle Positioning During Hamstring Stretches for Improving Straight Leg Hip Flexion Motion.

    Science.gov (United States)

    Laudner, Kevin G; Benjamin, Peter J; Selkow, Noelle M

    2016-03-01

    To compare the effects of stretching the hamstrings with the ankle in either a plantar-flexed (PF) or dorsiflexed (DF) position for improving straight leg hip flexion range of motion (ROM) over a 4-week period. Randomized, single-blinded, pretest, posttest design. Athletic training facility. Each limb of 34 asymptomatic individuals (15 males, 19 females) was randomly assigned to one of the 3 groups. Twenty-four limbs received hamstring stretches with the ankle in DF, 24 limbs received hamstring stretches with the ankle in PF, and 20 limbs received no stretch (control). Ankle position (PF, DF) during hamstring stretching. We measured pretest and posttest passive straight leg hip flexion ROM with the test ankle in a neutral position. For the intervention groups, the test limb was passively stretched with the ankle held in end range DF or PF for their respective group. Each stretch was held for 30 seconds for a total of 3 applications. Two treatment sessions were completed per week for a total of 4 weeks. The control limbs received no stretching during the 4-week period. We conducted 1-way analyses of covariance to determine significant changes in ROM between groups (P hamstrings in either PF or DF improve straight leg hip ROM compared with a control group. The results of this study should be considered by clinicians when determining the optimal stretching techniques aimed at increasing hamstring length.

  8. Technical exercises for the execution of straight punches in boxers of the child category

    Directory of Open Access Journals (Sweden)

    Giraldo Machuat Santana

    2017-12-01

    Full Text Available The present research aims to put into the hands of the coaches a material whose value in the methodological didactic can serve as a tool in the search for alternative solutions to the problems that today affect the technical and tactical preparation of our boxers from the point of view an offensive view, specifically on the effectiveness of straight blows to the face and trunk. For the accomplishment of this work a sample of 12 athletes was chosen, all belonging to the category 11-12 years of the municipality San Juan y Martínez to which as an experimental form ,the introduction of a methodology supported in a set of exercises was applied, as part of the teaching-learning process of athletes, regarding the execution of straight blows to the face and trunk, as an essential tactical offensive technical aspect in this age category to achieve victory in combat. A total of 16 observations were made to trainings and competitions to appreciate how the technique behaved in the execution of these blows by the athletes research subject. As a result there is a proposal of exercises that through a correct execution and implementation can contribute to the improvement of the effectiveness in the execution of the straight blows to the face and trunk of the boxers of the category 11 and 12 years of the combined sport nº 1 of the municipality San Juan y Martínez.

  9. Double-differential heavy-ion production cross sections

    International Nuclear Information System (INIS)

    Miller, T. M.; Townsend, L. W.

    2004-01-01

    Current computational tools used for space or accelerator shielding studies transport energetic heavy ions either using a one-dimensional straight-ahead approximation or by dissociating the nuclei into protons and neutrons and then performing neutron and proton transport using Monte Carlo techniques. Although the heavy secondary particles generally travel close to the beam direction, a proper treatment of the light ions produced in these reactions requires that double-differential cross sections should be utilised. Unfortunately, no fundamental nuclear model capable of serving as an event generator to provide these cross sections for all ions and energies of interest exists currently. Herein, we present a model for producing double-differential heavy-ion production cross sections that uses heavy-ion fragmentation yields produced by the NUCFRG2 fragmentation code coupled with a model of energy degradation in nucleus-nucleus collisions and systematics of momentum distributions to provide energy and angular dependences of the heavy-ion production. (authors)

  10. Pre-School Students' Informal Acquisitions Regarding the Concepts of Point and Straight Line

    Science.gov (United States)

    Orbay, Keziban; Develi, Mehmet Hikmet

    2015-01-01

    This study aimed to investigate the informal cognitive structures regarding "point" and "straight line"--two basic and undefined terms of geometry--in children registered in preschool--the previous step before in-class formal education process. The study was conducted with the participation of 50 children enrolled in nursery,…

  11. Understanding the Active Straight Leg Raise (ASLR): An electromyographic study in healthy subjects

    NARCIS (Netherlands)

    Hu, H.; Meijer, O.G.; Bruijn, S.M.; Strijers, R.L.M.; Nanayakkara, P.W.B.; van Royen, B.J.; Wu, W; Xia, C.; van Dieen, J.H.

    2012-01-01

    The Active Straight Leg Raise (ASLR) is an important test in diagnosing pelvic girdle pain (PGP). It is difficult to understand what happens normally during the ASLR, let alone why it would be impaired in PGP. In the present study, healthy subjects performed the ASLR under normal conditions, with

  12. Design and Validation of a Straight-Copy Typewriting Prognostic Test Using Kinesthetic Sensitivity.

    Science.gov (United States)

    Olson, Norma Jean

    1979-01-01

    Describes the development and application of a kinesthetic sensitivity test to determine whether it is a valid and reliable measure of straight-copy typing speed and accuracy. The author states that this kinesthetic sensitivity instrument may be used as a prognostic aptitude test and recommends administration methods. (MF)

  13. An Examination of Muscle Activation and Power Characteristics While Performing the Deadlift Exercise With Straight and Hexagonal Barbells.

    Science.gov (United States)

    Camara, Kevin D; Coburn, Jared W; Dunnick, Dustin D; Brown, Lee E; Galpin, Andrew J; Costa, Pablo B

    2016-05-01

    The deadlift exercise is commonly performed to develop strength and power, and to train the lower-body and erector spinae muscle groups. However, little is known about the acute training effects of a hexagonal barbell vs. a straight barbell when performing deadlifts. Therefore, the purpose of this study was to examine the hexagonal barbell in comparison with the straight barbell by analyzing electromyography (EMG) from the vastus lateralis, biceps femoris, and erector spinae, as well as peak force, peak power, and peak velocity using a force plate. Twenty men with deadlifting experience volunteered to participate in the study. All participants completed a 1 repetition maximum (1RM) test with each barbell on 2 separate occasions. Three repetitions at 65 and 85% 1RM were performed with each barbell on a third visit. The results revealed that there was no significant difference for 1RM values between the straight and hexagonal barbells (mean ± SD in kg = 181.4 ± 27.3 vs. 181.1 ± 27.6, respectively) (p > 0.05). Significantly greater normalized EMG values were found from the vastus lateralis for both the concentric (1.199 ± 0.22) and eccentric (0.879 ± 0.31) phases of the hexagonal-barbell deadlift than those of the straight-barbell deadlift (0.968 ± 0.22 and 0.559 ± 1.26), whereas the straight-barbell deadlift led to significantly greater EMG values from the bicep femoris during the concentric phase (0.835 ± 0.19) and the erector spinae (0.753 ± 0.28) during the eccentric phase than the corresponding values for the hexagonal-barbell deadlift (0.723 ± 0.20 and 0.614 ± 0.21) (p ≤ 0.05). In addition, the hexagonal-barbell deadlift demonstrated significantly greater peak force (2,553.20 ± 371.52 N), peak power (1,871.15 ± 451.61 W), and peak velocity (0.805 ± 0.165) values than those of the straight-barbell deadlift (2,509.90 ± 364.95 N, 1,639.70 ± 361.94 W, and 0.725 ± 0.138 m·s, respectively) (p ≤ 0.05). These results suggest that the barbells led

  14. Straight-run vs. sex separate rearing for two broiler genetic lines Part 2: Economic analysis and processing advantages.

    Science.gov (United States)

    Da Costa, M J; Colson, G; Frost, T J; Halley, J; Pesti, G M

    2017-07-01

    The objective of this analysis was to evaluate the effects of raising broilers under sex separate and straight-run conditions for 2 broiler genetic lines. One-day-old Ross 308 and Ross 708 chicks (n = 1,344) were sex separated and placed in 48 pens according to rearing type: sex separate (28 males or 28 females) or straight-run (14 males + 14 females). There were 3 dietary phases: starter (zero to 17 d), grower (17 to 32 d), and finisher (32 to 48 d). Bird individual BW and group feed intakes were measured at 12, 17, 25, 32, 42, and 48 d to evaluate performance. At 33, 43, and 49 d 4 birds per pen (straight-run pens 2 males + 2 females) were sampled for carcass yield evaluation. Data were analyzed using linear and non-linear regression in order to estimate feed intake and cut-up weights at 3 separate market weights (1,700, 2,700, and 3,700 g). Returns over feed cost were estimated for a 1.8 million broiler complex for each rearing system and under 9 feed/meat price scenarios. Overall, rearing birds that were sex separated resulted in extra income that ranged from ${\\$}$48,824 to ${\\$}$330,300 per week, depending on the market targeted and feed and meat price scenarios. Sex separation was shown to be especially important in disadvantageous scenarios in which feed prices were high. Gains from sex separation were markedly higher for the Ross 708 than for the Ross 308 broilers. Bird variability also was evaluated at the 3 separate market ages under narrow ranges of BW that were targeted. Straight-run birds decreased the number of birds present in the desired range. Depending on market weight, straight-run rearing resulted in 9.1 to 16.6% fewer birds than sex separate rearing to meet marketing goals. It was concluded that sex separation can result in increased company profitability and have possible beneficial effects at the processing plant due to increased bird uniformity. © 2017 Poultry Science Association Inc.

  15. Insertion forces and intracochlear trauma in temporal bone specimens implanted with a straight atraumatic electrode array.

    Science.gov (United States)

    Mirsalehi, Marjan; Rau, Thomas S; Harbach, Lenka; Hügl, Silke; Mohebbi, Saleh; Lenarz, Thomas; Majdani, Omid

    2017-05-01

    The aim of the study was to evaluate insertion forces during manual insertion of a straight atraumatic electrode in human temporal bones, and post-implantation histologic evaluation of the samples to determine whether violation of intracochlear structures is related to insertion forces. In order to minimize intracochlear trauma and preserve residual hearing during cochlear implantation, knowledge of the insertion forces is necessary. Ten fresh frozen human temporal bones were prepared with canal wall down mastoidectomy. All samples were mounted on a one-axis force sensor. Insertion of a 16-mm straight atraumatic electrode was performed from different angles to induce "traumatic" insertion. Histologic evaluation was performed in order to evaluate intracochlear trauma. In 4 of 10 samples, dislocation of the electrode into scala vestibuli was observed. The mean insertion force for all 10 procedures was 0.003 ± 0.005 N. Insertion forces measured around the site of dislocation to scala vestibuli in 3 of 4 samples were significantly higher than insertion forces at the same location of the cochleae measured in samples without trauma (p straight atraumatic electrode is lower than reported by other studies using longer electrodes. Based on our study, insertion forces leading to basilar membrane trauma may be lower than the previously reported direct rupture forces.

  16. A Comparison of pical Root Resorption in Incisors after Fixed Orthodontic Treatment with Standard Edgewise and Straight Wire (MBT) Method.

    Science.gov (United States)

    Zahed Zahedani, Sm; Oshagh, M; Momeni Danaei, Sh; Roeinpeikar, Smm

    2013-09-01

    One of the major outcomes of orthodontic treatment is the apical root resorption of teeth moved during the treatment. Identifying the possible risk factors, are necessary for every orthodontist. The aim of this study was to compare the rate of apical root resorption after fixed orthodontic treatment with standard edgewise and straight wire (MBT) method, and also to evaluate other factors effecting the rate of root resorption in orthodontic treatments. In this study, parallel periapical radiographs of 127 patients imaging a total of 737 individual teeth, were collected. A total of 76 patients were treated by standard edgewise and 51 patients by straight wire method. The periapical radiographs were scanned and then the percentage of root resorption was calculated by Photoshop software. The data were analyzed by Paired-Samples t-test and the Generalized Linear Model adopting the SPSS 15.0. In patients treated with straight wire method (MBT), mean root resorption was 18.26% compared to 14.82% in patients treated with standard edgewise technique (proot resorption,statistically significant (proot resorption in this study. Having more root resorption in the straight wire method and less in the standard edgewise technique can be attributed to more root movement in pre-adjusted MBT technique due to the brackets employed in this method.

  17. Assessment of corneal astigmatism following frown and straight incision forms in sutureless manual small incision cataract surgery

    Directory of Open Access Journals (Sweden)

    Amedo AO

    2016-04-01

    Full Text Available Angela Ofeibea Amedo, Kwadwo Amoah, Nana Yaa Koomson, David Ben Kumah, Eugene Appenteng Osae Department of Optometry and Visual Science, Kwame Nkrumah University of Science and Technology, Kumasi, Ghana Abstract: To investigate which of two tunnel incision forms (frown versus straight in sutureless manual small incision cataract surgery creates more corneal astigmatism. Sixty eyes of 60 patients who had consented to undergo cataract surgery and to partake in this study were followed from baseline through >12-week postoperative period. Values of preoperative and postoperative corneal astigmatism for the 60 eyes, measured with a Bausch and Lomb keratometer, were extracted from the patients’ cataract surgery records. Residual astigmatism was computed as the difference between preoperative and postoperative keratometry readings. Visual acuity was assessed during the preoperative period and at each postoperative visit with a Snellen chart at 6 m. Fifty eyes of 50 patients were successfully followed-up on. Overall, the mean residual astigmatism was 0.75±0.12 diopters. The differences in mean residual astigmatism between the two different incision groups were statistically significant (t [48]=6.33, P<0.05; frown incision group recorded 1.00±0.12 diopters, whereas the straight incision group recorded 0.50±0.12 diopters. No significant difference was observed between male and female groups (t [48]=0.24, P>0.05. Residual corneal astigmatism in the frown incision group was significantly higher than in the straight incision group. Fisher’s exact test did not reveal a significant association between incision forms and visual acuity during the entire postoperative period (P>0.05. Keywords: cataract, residual corneal astigmatism, frown incision, straight incision

  18. Determining shapes and dimensions of dental arches for the use of straight-wire arches in lingual technique

    Directory of Open Access Journals (Sweden)

    Silvana Allegrini Kairalla

    2014-10-01

    Full Text Available INTRODUCTION: This study aims to determine the shape and dimension of dental arches from a lingual perspective, and determine shape and size of a straight archwire used for lingual Orthodontics. METHODS: The study sample comprised 70 Caucasian Brazilian individuals with normal occlusion and at least four of Andrew's six keys. Maxillary and mandibular dental casts were digitized (3D and the images were analyzed by Delcam Power SHAPET 2010 software. Landmarks on the lingual surface of teeth were selected and 14 measurements were calculated to determine the shape and size of dental arches. RESULTS: Shapiro-Wilk test determined small arch shape by means of 25th percentile (P25% - an average percentile for the medium arch; and a large one determined by means of 75th percentile (P75%. T-test revealed differences between males and females in the size of 12 dental arches. CONCLUSION: The straight-wire arch shape used in the lingual straight wire technique is a parabolic-shaped arch, slightly flattened on its anterior portion. Due to similarity among dental arch sizes shown by males and females, a more simplified diagram chart was designed.

  19. The promotion of unhealthy habits in gay, lesbian, and straight intimate partnerships.

    Science.gov (United States)

    Reczek, Corinne

    2012-09-01

    Health habits are linked to nearly half of U.S. and British deaths annually. While a legacy of research suggests that marriage has important positive consequences for health habits, recent work emphasizes that intimate ties can also deter from healthy habits and promote unhealthy habits. However, few studies examine the mechanisms through which unhealthy habits are promoted in marriage. Moreover, little research explores how unhealthy habits are promoted in intimate ties other than marriage-such as in gay and lesbian cohabiting relationships. The present study analyzes the mechanisms through which gay, lesbian, and straight long-term partners (N = 120) contribute to one another's unhealthy habits. Three distinct mechanisms emerge. First, respondents identify a process of unilateral health habit diffusion wherein one partner's health habits directly influence the other partners' habits. Second, respondents describe bilateral unhealthy habit diffusion, wherein both partner's unhealthy habits are reinforced via mutual pleasure seeking or mutual failed motivation. Third, respondents describe a discourse of personal responsibility, wherein both partners purposefully fail to deter one another's unhealthy habits. Analysis further illustrates how these mechanisms operate differently for men and women in gay, lesbian, and straight relationships. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Application of failure assessment diagram methods to cracked straight pipes and elbows

    International Nuclear Information System (INIS)

    Ainsworth, R.A.; Gintalas, M.; Sahu, M.K.; Chattopadhyay, J.; Dutta, B.K.

    2016-01-01

    This paper reports fracture assessments of large-scale straight pipes and elbows of various pipe diameters and crack sizes. The assessments estimate the load for ductile fracture initiation using the failure assessment diagram method. Recent solutions in the literature for stress intensity factor and limit load provide the analysis inputs. An assessment of constraint effects is also performed using recent solutions for elastic T-stress. It is found that predictions of initiation load are close to the experimental values for straight pipes under pure bending. For elbows, there is generally increased conservatism in the sense that the experimental loads are greater than those predicted. The effects of constraint are found not to be a major contributor to the initiation fracture assessments but may have some influence on the ductile crack extension. - Highlights: • This paper presents assessments of the loads for ductile fracture initiation in 21 large-scale piping tests. • Modern stress intensity factor and limit load solutions were used for standard failure assessment diagram methods. • This leads to generally accurate assessments of the loads for ductile crack initiation. • The effects of constraint are found not to be a major contributor to the initiation fracture assessments.

  1. Limited effect of dopaminergic medication on straight walking and turning in early to moderate Parkinson’s disease during single and dual tasking

    Directory of Open Access Journals (Sweden)

    Morad eElshehabi

    2016-01-01

    Full Text Available Background: In Parkinson’s disease (PD, the effects of dopaminergic medication on straight walking and turning were mainly investigated under single tasking (ST conditions. However, multitasking situations are considered more daily relevant.Methods: Thirty-nine early to moderate PD patients performed the following standarized ST and dual tasks (DT as fast as possible for one minute during On- and Off-medication while wearing inertial sensors: straight walking and turning, checking boxes, and subtracting serial 7s. Quantitative gait parameters, as well as velocity of the secondary tasks were analyzed.Results: The following parameters improved significantly in On-medication during ST: gait velocity during straight walking (p=0.03; step duration (p=0.048 and peak velocity (p=0.04 during turning; velocity of checking boxes during ST (p=0.04 and DT (p=0.04. Velocity of checking boxes was the only parameter that also improved during DT.Conclusion: These results suggest that dopaminergic medication does not relevantly influence straight walking and turning in early to moderate PD during DT.

  2. Skin reduction technique for correction of lateral deviation of the erect straight penis.

    Science.gov (United States)

    Shaeer, Osama

    2014-07-01

    Lateral deviation of the erect straight penis (LDESP) refers to a penis that despite being straight in the erect state, points laterally, yet can be directed forward manually without the use of force. While LDESP should not impose a negative impact on sexual function, it may have a negative cosmetic impact. This work describes skin reduction technique (SRT) for correction of LDESP. Counseling was offered to males with LDESP after excluding other abnormalities. Surgery was performed in case of failed counseling. In the erect state, the degree and direction of LDESP were noted. Skin on the base of the penis on the contralateral side of LDESP was excised from the base of the penis and the edges approximated to correct LDESP. Further excision was repeated if needed. The incision was closed in two layers. Long-term efficacy of SRT was the main outcome measure. Out of 183 males with LDESP, 66.7% were not sexually active. Counseling relieved 91.8% of cases. Fifteen patients insisted on surgery, mostly from among the sexually active where the complaint was mutual from the patient and partner. SRT resulted in full correction of the angle of erection in 12 cases out of 15. Two had minimal recurrence, and one had major recurrence indicating re-SRT. LDESP is more common a complaint among those who have not experienced coital relationship, and is mostly relieved by counseling. However, sexually active males with this complaint are more difficult to relieve by counseling. A minority of patients may opt for surgical correction. SRT achieves a forward erection in such patients, is minimally invasive, and relatively safe, provided the angle of erection can be corrected manually without force. Shaeer O. Skin reduction technique for correction of lateral deviation of the erect straight penis. © 2014 International Society for Sexual Medicine.

  3. Absorption of short-pulse electromagnetic energy by a resistively loaded straight wire

    International Nuclear Information System (INIS)

    Miller, E.K.; Deadrick, F.J.; Landt, J.A.

    1975-01-01

    Absorption of short-pulse electromagnetic energy by a resistively loaded straight wire is examined. Energy collected by the wire, load energy, peak load currents, and peak load voltages are found for a wide range of parameters, with particular emphasis on nuclear electromagnetic pulse (EMP) phenomena. A series of time-sequenced plots is used to illustrate pulse propagation on wires when loads and wire ends are encountered

  4. Optimizing the injection straight of PEP II asymmetric B Factory at SLAC

    International Nuclear Information System (INIS)

    Bulos, F.; Bloom, E.; Davies-White, W.; Donald, M.; Fairfield, K.; Fieguth, T.; Godfrey, G.; Holtzapple, R.; Hutton, A.; Loew, G.; Miller, R.; Sukiennicki, B.; Wen, H.; Ronan, M.

    1992-04-01

    The asymmetric energy PEP II B Factory proposed as an upgrade of PEP at the Stanford Linear Accelerator Center requires both a powerful low emittance source of e - e + and a very reliable and efficient injection system. The SLC linac fulfills the source requirement very well. We describe here the optimization of the optics of the injection straight to insure reliable and efficient injection

  5. Optimizing the injection straight of PEP II asymmetric B factory at SLAC

    International Nuclear Information System (INIS)

    Bulos, F.; Bloom, E.; Davies-White, W.; Donald, M.; Fairfield, K.; Fieguth, T.; Godfrey, G.; Holtzapple, R.; Hutton, A.; Loew, G.; Miller, R.; Sukiennicki, B.; Wen, H.

    1992-01-01

    The asymmetric energy PEP II B Factory proposed as an upgrade of PEP at the Stanford Linear Accelerator Center requires both a powerful low emittance source of e - e + and a very reliable and efficient injection system. The SLC linac fulfills the source requirement very well. We describe here the optimization of the optics of the injection straight to insure reliable and efficient injection

  6. Gamma-ray streaming in straight pipes and bent ducts

    International Nuclear Information System (INIS)

    Eid, M.; Diop, C.M.; Nimal, J.C.

    1985-04-01

    An important shielding problem is the gamma-ray streaming through voids. These problems are encountered in the reactors and reprocessing plants. A Monte Carlo method has been choosed as one of the most powerful technics to solve this kind of problems. Here in that frame, a biasing system which is adapted for two types of geometries is proposed: straight pipes and bent ducts. A code has been written applying this technique. The numerical results obained show the efficiency and the very good economy of the method proposed. It is hoped to extend the method to deal with more complex geometries and polykinetic situation as well

  7. Effect of cisplatin on proximal convoluted and straight segments of the rat kidney

    DEFF Research Database (Denmark)

    Daugaard, G; Holstein-Rathlou, N H; Leyssac, P P

    1988-01-01

    lithium clearance (CLi/Cin) and e-TT/OT was observed (from 270 +/- 32 to 387 +/- 60 microliters/min/g kidney weight, 0.202 +/- 0.03 to 0.340 +/- 0.06 and 0.415 +/- 0.02 to 0.497 +/- 0.02, respectively). These increases indicate an increased fluid delivery from both the proximal straight segment...

  8. Hydrodynamic shrinkage of liquid CO2 Taylor drops in a straight microchannel

    Science.gov (United States)

    Qin, Ning; Wen, John Z.; Ren, Carolyn L.

    2018-03-01

    Hydrodynamic shrinkage of liquid CO2 drops in water under a Taylor flow regime is studied using a straight microchannel (length/width ~100). A general form of a mathematical model of the solvent-side mass transfer coefficient (k s) is developed first. Based on formulations of the surface area (A) and the volume (V) of a general Taylor drop in a rectangular microchannel, a specific form of k s is derived. Drop length and speed are experimentally measured at three specified positions of the straight channel, namely, immediately after drop generation (position 1), the midpoint of the channel (position 2) and the end of the channel (position 3). The reductions of drop length (L x , x  =  1, 2, 3) from position 1 to 2 and down to 3 are used to quantify the drop shrinkage. Using the specific model, k s is calculated mainly based on L x and drop flowing time (t). Results show that smaller CO2 drops produced by lower flow rate ratios ({{Q}LC{{O2}}}/{{Q}{{H2}O}} ) are generally characterized by higher (nearly three times) k s and Sherwood numbers than those produced by higher {{Q}LC{{O2}}}/{{Q}{{H2}O}} , which is essentially attributed to the larger effective portion of the smaller drop contributing in the mass transfer under same levels of the flowing time and the surface-to-volume ratio (~104 m-1) of all drops. Based on calculated pressure drops of the segmented flow in microchannel, the Peng-Robinson equation of state and initial pressures of drops at the T-junction in experiments, overall pressure drop (ΔP t) in the straight channel as well as the resulted drop volume change are quantified. ΔP t from position 1-3 is by average 3.175 kPa with a ~1.6% standard error, which only leads to relative drop volume changes of 0.3‰ to 0.52‰.

  9. Hydrodynamic shrinkage of liquid CO2 Taylor drops in a straight microchannel.

    Science.gov (United States)

    Qin, Ning; Wen, John; Ren, Carolyn L

    2018-01-16

    Hydrodynamic shrinkage of liquid CO2 drops in water under a Taylor flow regime is studied using a straight microchannel (length/width ~ 100). A general form of a mathematical model of the solvent-side mass transfer coefficient (ks) is developed first. Based on formulations of the surface area (A) and the volume (V) of a general Taylor drop in a rectangular microchannel, a specific form of ks is derived. Drop length and speed are experimentally measured at three specified positions of the straight channel, namely, immediately after drop generation (position 1), the midpoint of the channel (position 2) and the end of the channel (position 3). The reductions of drop length (Lx, x = 1, 2, 3) from position 1 to 2 and down to 3 are used to quantify the drop shrinkage. Using the specific model, ks is calculated mainly based on Lx and drop flowing time (t). Results show that smaller CO2 drops produced by lower flow rate ratios (QLCO2/QH2O) are generally characterized by higher (nearly three times) ks and Sherwood numbers than those produced by higher QLCO2/QH2O, which is essentially attributed to the larger effective portion of the smaller drop contributing in the mass transfer under same levels of the flowing time and the surface-to-volume ratio (~ 104 m-1) of all drops. Based on calculated pressure drops of the segmented flow in microchannel, the Peng-Robinson equation of state (EOS) and initial pressures of drops at the T-junction in experiments, overall pressure drop (ΔPt) in the straight channel as well as the resulted drop volume change are quantified. ΔPt from position 1 to 3 is by average 3.175 kPa with a ~1.6% standard error, which only leads to relative drop volume changes of 0.3‰ to 0.52‰. © 2018 IOP Publishing Ltd.

  10. Prediction of the Flash Point of Binary and Ternary Straight-Chain Alkane Mixtures

    Directory of Open Access Journals (Sweden)

    X. Li

    2014-01-01

    Full Text Available The flash point is an important physical property used to estimate the fire hazard of a flammable liquid. To avoid the occurrence of fire or explosion, many models are used to predict the flash point; however, these models are complex, and the calculation process is cumbersome. For pure flammable substances, the research for predicting the flash point is systematic and comprehensive. For multicomponent mixtures, especially a hydrocarbon mixture, the current research is insufficient to predict the flash point. In this study, a model was developed to predict the flash point of straight-chain alkane mixtures using a simple calculation process. The pressure, activity coefficient, and other associated physicochemical parameters are not required for the calculation in the proposed model. A series of flash points of binary and ternary mixtures of straight-chain alkanes were determined. The results of the model present consistent experimental results with an average absolute deviation for the binary mixtures of 0.7% or lower and an average absolute deviation for the ternary mixtures of 1.03% or lower.

  11. A mathematical model for the motion analysis of embedded straight microcantilevers under a pressure-driven flow

    International Nuclear Information System (INIS)

    Ezkerra, A; Mayora, K; Ruano-López, J M; Wilson, P A

    2008-01-01

    A mathematical model that estimates the deflection of straight microcantilevers embedded in a microchannel under a pressure-driven flow at low Reynolds numbers is presented. The model makes use of the Schwarz–Christoffel mapping in order to couple the geometry of the structure and the flow passing around it. Therefore, it allows the determination of the most influential parameters and suitable modifications in order to achieve the desired performance. The model does not require specific knowledge of the flow conditions in the vicinity of the structure, which improves its practical use during the early stages of design. Estimations have been made for two straight cantilevers under a range of pressures. The results obtained show good agreement with measurements from experiments

  12. Finding the Quickest Straight-Line Trajectory for a Three-Wheeled Omnidirectional Robot under Input Voltage Constraints

    Directory of Open Access Journals (Sweden)

    Ki Bum Kim

    2015-01-01

    Full Text Available We provide an analytical solution to the problem of generating the quickest straight-line trajectory for a three-wheeled omnidirectional mobile robot, under the practical constraint of limited voltage. Applying the maximum principle to the geometric properties of the input constraints, we find that an optimal input vector of motor voltages has at least one extreme value when the orientation of the robot is fixed and two extreme values when rotation is allowed. We can find an explicit representation of the optimal vector for a motion under fixed orientation. We derive several properties of quickest straight-line trajectories and verify them through simulation. We show that the quickest trajectory when rotation is allowed is always faster than the quickest with fixed orientation.

  13. Shielded transient self-interaction of a bunch entering a circle from a straight path

    International Nuclear Information System (INIS)

    Li, R.; Bohn, C.L.; Bisognano, J.J.

    1997-01-01

    Recent developments in electron-gun and injector technologies enable production of short (mm-length), high-charge (nC-regime) bunches. In this parameter regime, the curvature effect on the bunch self-interaction, by way of coherent synchrotron radiation (CSR) and space-charge forces as the beam traverses magnet bends, may cause serious emittance degradation. In this paper, the authors study an electron bunch orbiting between two infinite, parallel conducting plates. The bunch moves on a trajectory from a straight path to a circular orbit and begins radiating. Transient effects, arising from CSR and space-charge forces generated from source particles both on the bend and on the straight path prior to the bend, are analyzed using Lienard-Wiechert fields, and their overall net effect is obtained. The influence of the plates on the transients is contrasted to their shielding of the steady-state radiated power. Results for emittance degradation induced by this self-interaction are also presented

  14. Making Schools Safe and Inclusive: Gay-Straight Alliances and School Climate in Ontario

    Science.gov (United States)

    Kitchen, Julian; Bellini, Christine

    2013-01-01

    Gay-straight alliances (GSAs) have become widespread in Ontario schools and, starting in 2012, all schools are required to permit students to form GSAs. While American research suggests that GSAs have a positive impact on school safety and inclusion, there is little research on the impact of GSAs in Canadian schools. This study, based on a survey…

  15. Darboux integrability and rational reversibility in cubic systems with two invariant straight lines

    Directory of Open Access Journals (Sweden)

    Dumitru Cozma

    2013-01-01

    Full Text Available We find conditions for a singular point O(0,0 of a center or a focus type to be a center, in a cubic differential system with two distinct invariant straight lines. The presence of a center at O(0,0 is proved by using the method of Darboux integrability and the rational reversibility.

  16. Use of Straight –Run Gasoline (Srg) as A Leaching Solvent for Oil ...

    African Journals Online (AJOL)

    A study was conducted on the use of straight-run gasoline (SRG) as an extraction solvent for the leaching of palm kernel to produce palm kernel oil (PKO). SRG is an intermediate product fraction in the second fraction of crude petroleum oil fractionation that has not undergone any purification process. It is intended as a ...

  17. Destabilizing Anti-Gay Environments through Gay-Straight Alliances: Possibilities and Limitations through Shifting Discourses

    Science.gov (United States)

    Currie, Sean; Mayberry, Maralee; Chenneville, Tiffany

    2012-01-01

    Drawing upon research with Gay-Straight Alliance (GSA) advisors, high-school principals, and two district-level administrators, we examine the potential and limits of the safe-space discourse that encompasses the aims of GSAs. We argue that this discourse conceals heteronormative school environments, which supplies the groundwork for hostility…

  18. Charged Particle Dynamics in the Magnetic Field of a Long Straight Current-Carrying Wire

    Science.gov (United States)

    Prentice, A.; Fatuzzo, M.; Toepker, T.

    2015-01-01

    By describing the motion of a charged particle in the well-known nonuniform field of a current-carrying long straight wire, a variety of teaching/learning opportunities are described: 1) Brief review of a standard problem; 2) Vector analysis; 3) Dimensionless variables; 4) Coupled differential equations; 5) Numerical solutions.

  19. Straight and chopped DC performance data for a General Electric 5BY436A1 DC shunt motor with a General Electric EV-1 controller

    Science.gov (United States)

    Edie, P. C.

    1981-01-01

    Both straight and chopped dc motor performance data for a General Electric 5BY436A1 motor with a General Electric EV-1 controller is presented in tabular and graphical formats. Effects of motor temperature and operating voltage are also shown. The maximum motor efficiency is approximately 85% at low operating temperatures in the straight dc mode. Chopper efficiency can be assumed to be 95% under all operating conditions. For equal speeds, the motor operated in the chopped mode develops slightly more torque and draws more current than it does in the straight mode.

  20. A unifying model for planform straightness of ripples and dunes in air and water

    Science.gov (United States)

    Rubin, David M.

    2012-01-01

    Geologists, physicists, and mathematicians have studied ripples and dunes for more than a century, but despite considerable effort, no general model has been proposed to explain perhaps the most fundamental property of their morphology: why are some bedforms straight, continuous, parallel, and uniform in planform geometry (i.e. two-dimensional) whereas others are irregular (three-dimensional)? Here we argue that physical coupling along the crest of a bedform is required to produce straight crests and that along-crest flow and sand transport provide effective physical mechanisms for that coupling. Ripples and dunes with the straightest and most continuous crests include longitudinal and oblique dunes in unidirectional flows, wave ripples, dunes in reversing flows, wind ripples, and ripples migrating along a slope. At first glance, these bedforms appear quite different (ripples and dunes; air and water; transverse, oblique, and longitudinal orientations relative to the net sand-transport direction), but they all have one property in common: a process that increases the amount of along-crest sand transport (that lengthens and straightens their crests) relative to the across-crest transport (that makes them migrate and take the more typical and more three-dimensional planform geometry). In unidirectional flows that produce straight bedforms, along-crest transport of sand is caused by along-crest flow (non-transverse bedform orientation), gravitational transport along an inclined crest, or ballistic splash in air. Bedforms in reversing flows tend to be straighter than their unidirectional counterparts, because reverse transport across the bedform crest reduces the net across-crest transport (that causes the more typical irregular geometry) relative to the along-crest transport (that smoothes and straightens planform geometry).

  1. Experimental and Modeling Damage Limits Study for Straight Ti-3A1-2.5V Tubes

    National Research Council Canada - National Science Library

    Gupta, Mool C; Lin, Yaomin; Ni, Kan; Wong, Teh-Hwa; Woodland, Kevin; Grose, Tim; Spidel, Tom; Stone, Bill; Yu, Michael; Taylor, Bob; Lei, Charles; Williams, Reanne

    2007-01-01

    To insure the safety of the V-22 aircraft over long period of operation, damage limits should be established for Ti alloy hydraulic tubes In a previous report, the damage limit results for straight...

  2. Large Eddy Simulation of turbulence induced secondary flows in stationary and rotating straight square ducts

    Science.gov (United States)

    Sudjai, W.; Juntasaro, V.; Juttijudata, V.

    2018-01-01

    The accuracy of predicting turbulence induced secondary flows is crucially important in many industrial applications such as turbine blade internal cooling passages in a gas turbine and fuel rod bundles in a nuclear reactor. A straight square duct is popularly used to reveal the characteristic of turbulence induced secondary flows which consists of two counter rotating vortices distributed in each corner of the duct. For a rotating duct, the flow can be divided into the pressure side and the suction side. The turbulence induced secondary flows are converted to the Coriolis force driven two large circulations with a pair of additional vortices on the pressure wall due to the rotational effect. In this paper, the Large Eddy Simulation (LES) of turbulence induced secondary flows in a straight square duct is performed using the ANSYS FLUENT CFD software. A dynamic kinetic energy subgrid-scale model is used to describe the three-dimensional incompressible turbulent flows in the stationary and the rotating straight square ducts. The Reynolds number based on the friction velocity and the hydraulic diameter is 300 with the various rotation numbers for the rotating cases. The flow is assumed fully developed by imposing the constant pressure gradient in the streamwise direction. For the rotating cases, the rotational axis is placed perpendicular to the streamwise direction. The simulation results on the secondary flows and the turbulent statistics are found to be in good agreement with the available Direct Numerical Simulation (DNS) data. Finally, the details of the Coriolis effects are discussed.

  3. Comparison of waveguide properties of curved versus straight planar elastic layers

    DEFF Research Database (Denmark)

    Zadeh, Maziyar Nesari; Sorokin, Sergey

    2013-01-01

    Dispersion equations are solved for the in-plane and anti-plane wave propagation in planar elastic layer with constant curvature. The classical Lamé formulation of displacements via elastic potentials is applied and appropriate simplifications are employed. The dispersion diagrams in each case...... are compared with their counterparts for a straight layer, e.g., the classical Rayleigh–Lamb solution. The curvature-induced symmetry-breaking effects are investigated for layers with symmetric boundary conditions. The role of curvature is also investigated in the cases, when the boundary conditions...

  4. Straight line foraging in yellow-eyed penguins: new insights into cascading fisheries effects and orientation capabilities of marine predators.

    Science.gov (United States)

    Mattern, Thomas; Ellenberg, Ursula; Houston, David M; Lamare, Miles; Davis, Lloyd S; van Heezik, Yolanda; Seddon, Philip J

    2013-01-01

    Free-ranging marine predators rarely search for prey along straight lines because dynamic ocean processes usually require complex search strategies. If linear movement patterns occur they are usually associated with travelling events or migratory behaviour. However, recent fine scale tracking of flying seabirds has revealed straight-line movements while birds followed fishing vessels. Unlike flying seabirds, penguins are not known to target and follow fishing vessels. Yet yellow-eyed penguins from New Zealand often exhibit directed movement patterns while searching for prey at the seafloor, a behaviour that seems to contradict common movement ecology theories. While deploying GPS dive loggers on yellow-eyed penguins from the Otago Peninsula we found that the birds frequently followed straight lines for several kilometres with little horizontal deviation. In several cases individuals swam up and down the same line, while some of the lines were followed by more than one individual. Using a remote operated vehicle (ROV) we found a highly visible furrow on the seafloor most likely caused by an otter board of a demersal fish trawl, which ran in a straight line exactly matching the trajectory of a recent line identified from penguin tracks. We noted high abundances of benthic scavengers associated with fisheries-related bottom disturbance. While our data demonstrate the acute way-finding capabilities of benthic foraging yellow-eyed penguins, they also highlight how hidden cascading effects of coastal fisheries may alter behaviour and potentially even population dynamics of marine predators, an often overlooked fact in the examination of fisheries' impacts.

  5. Straight line foraging in yellow-eyed penguins: new insights into cascading fisheries effects and orientation capabilities of marine predators.

    Directory of Open Access Journals (Sweden)

    Thomas Mattern

    Full Text Available Free-ranging marine predators rarely search for prey along straight lines because dynamic ocean processes usually require complex search strategies. If linear movement patterns occur they are usually associated with travelling events or migratory behaviour. However, recent fine scale tracking of flying seabirds has revealed straight-line movements while birds followed fishing vessels. Unlike flying seabirds, penguins are not known to target and follow fishing vessels. Yet yellow-eyed penguins from New Zealand often exhibit directed movement patterns while searching for prey at the seafloor, a behaviour that seems to contradict common movement ecology theories. While deploying GPS dive loggers on yellow-eyed penguins from the Otago Peninsula we found that the birds frequently followed straight lines for several kilometres with little horizontal deviation. In several cases individuals swam up and down the same line, while some of the lines were followed by more than one individual. Using a remote operated vehicle (ROV we found a highly visible furrow on the seafloor most likely caused by an otter board of a demersal fish trawl, which ran in a straight line exactly matching the trajectory of a recent line identified from penguin tracks. We noted high abundances of benthic scavengers associated with fisheries-related bottom disturbance. While our data demonstrate the acute way-finding capabilities of benthic foraging yellow-eyed penguins, they also highlight how hidden cascading effects of coastal fisheries may alter behaviour and potentially even population dynamics of marine predators, an often overlooked fact in the examination of fisheries' impacts.

  6. Small Woods Where I Met Myself : Jerry Uelsmann's departure from straight photography

    OpenAIRE

    Petersén, Moa

    2018-01-01

    In the article I investigate the differences between Ansel Adams' and Jerry Uelsmann's use of nature in their respective photography. Through their attitudes, approaches to, and involvement with nature their different relations to the photographic medium and the creative process unfold. Uelsmann's departure from the straight photographic tradition - that Ansel Adams came to symbolize - is in the article explained through an analysis of Uelsmann's and Adams' use of nature in their respective a...

  7. The effect of gamma radiation on seeds and plants of different genotypes of Pisum arvense (L.s.s.) in the M1 generation

    International Nuclear Information System (INIS)

    Jaranowski, J.K.

    1976-01-01

    This paper presents results concerning radiosensitivity of seeds of field pea (Pisum arvense L.s.s.) and the analysis of the M 1 generation plants. For the present studies seeds of seven established (homozygous) lines, derived from crosses between forms and varieties of different agriculturo-geographical regions of Europe, were chosen. These lines differed by a number of morphological and physiological characters. The seeds were exposed to gamma radiation at the doses of: 1 kR/5 hrs, 6 kR/25 hrs, 12 kR/100 hrs, 25 kR/100 hrs and 50 kR/100 hrs. While analysing after the irradiation such phenomena as germinating and emergence capacity, survival of plants after emergence, morphological changes of plants, fertility and chromosome aberrations, it has been found that the radiosensitivity of various lines is convincingly different. Attempts to find certain correlations between the presence of definite genes in the lines, the size and structure of chromosomes, the structure of seeds (size, shape, coloration) gave negative results. Results obtained by the author and those of the literature indicate that radiosensitivity of pea seeds and characters of the M 1 generation plants are very complicated phenomena and it is difficult to establish definite regularities. (author)

  8. Straight-leg rasing in 'short hamstrings'. An experimental study of muscle elasticy and defense reactions.

    NARCIS (Netherlands)

    Göeken, Ludwig Nanno Hiltjo

    1988-01-01

    The central guestion asked in this thesis is whether an Experimental Straight-Leg Raising test (E.S.L.R.) can contribute to the solution of a diagnostical problem frequently encountered in rehabilitation medicine. It concerns the determination of the cause of the movement restriction in patients who

  9. AUTOMATIC GLOBAL REGISTRATION BETWEEN AIRBORNE LIDAR DATA AND REMOTE SENSING IMAGE BASED ON STRAIGHT LINE FEATURES

    Directory of Open Access Journals (Sweden)

    Z. Q. Liu

    2018-04-01

    Full Text Available An automatic global registration approach for point clouds and remote sensing image based on straight line features is proposed which is insensitive to rotational and scale transformation. First, the building ridge lines and contour lines in point clouds are automatically detected as registration primitives by integrating region growth and topology identification. Second, the collinear condition equation is selected as registration transformation function which is based on rotation matrix described by unit quaternion. The similarity measure is established according to the distance between the corresponding straight line features from point clouds and the image in the same reference coordinate system. Finally, an iterative Hough transform is adopted to simultaneously estimate the parameters and obtain correspondence between registration primitives. Experimental results prove the proposed method is valid and the spectral information is useful for the following classification processing.

  10. Lumbar spondylosis, lumbar spinal stenosis, knee pain, back muscle strength are associated with the locomotive syndrome: Rural population study in Japan.

    Science.gov (United States)

    Chiba, Daisuke; Tsuda, Eiichi; Wada, Kanichiro; Kumagai, Gentaro; Sasaki, Eiji; Nawata, Atsushi; Nakagomi, Sho; Takahashi, Ippei; Nakaji, Shigeyuki; Ishibashi, Yasuyuki

    2016-05-01

    To comprehensively investigate the clinical and physical factors associating with locomotive syndrome (Loc-S); the locomotorium-disability for daily life. 647 volunteers participated (247 males, 400 females, Age: 58.4 ± 11.0, BMI: 22.5 ± 3.3). Three self-assessment questionnaires were administered: 1) "25-question Geriatric Locomotive Function Scale" (GFLS-25) for evaluating Loc-S (GLFS-25 ≥ 16 defined as Loc-S); 2) "diagnostic support tool for LSS" (LSS-DST) for evaluating the prevalence of lumbar spinal stenosis (LSS); 3) Knee injury and Osteoarthritis Outcome Score (KOOS). Plain radiographs of the bilateral knees and lumbar spine were evaluated, and the severity of lumbar spondylosis (LS) and knee osteoarthritis (KOA) defined by Kellgren-Lawrence grade. Bone status was evaluated by using the osteo-sono assessment index (OSI) at the calcaneus. Isometric muscle strength of trunk and leg (Nm/kg, both extension and flexion) were evaluated. Linear regression analysis was performed to elucidate the factors concerned with GFLS-25 including age, sex, and BMI. Thirty-nine subjects (6.0%, 13 males, 26 females) were defined as having Loc-S. Single regression model showed that age, height, BMI, skeletal muscle mass, OSI, LSS, KOOS, the severity of LS and KOA, and trunk- and leg-muscle strength were correlated with the degree of GLFS-25. Stepwise multiple regression model showed that sex, height, LSS, KOOS, the severity of LS, and back muscle strength were significantly correlated with that of GLFS-25. In this cross-sectional study, pain status associated with LSS and knee joint, structural severity for LS, and back muscle strength primarily affected the degree of GFLS-25. For managing Loc-S, we must pay more intensive attention to these factors. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  11. The measurements of water flow rates in the straight microchannel based on the scanning micro-PIV technique

    Science.gov (United States)

    Wang, H. L.; Han, W.; Xu, M.

    2011-12-01

    Measurement of the water flow rate in microchannel has been one of the hottest points in the applications of microfluidics, medical, biological, chemical analyses and so on. In this study, the scanning microscale particle image velocimetry (scanning micro-PIV) technique is used for the measurements of water flow rates in a straight microchannel of 200μm width and 60μm depth under the standard flow rates ranging from 2.481μL/min to 8.269μL/min. The main effort of this measurement technique is to obtain three-dimensional velocity distribution on the cross sections of microchannel by measuring velocities of the different fluid layers along the out-of-plane direction in the microchannel, so the water flow rates can be evaluated from the discrete surface integral of velocities on the cross section. At the same time, the three-dimensional velocity fields in the measured microchannel are simulated numerically using the FLUENT software in order to verify the velocity accuracy of measurement results. The results show that the experimental values of flow rates are well consistent to the standard flow rates input by the syringe pump and the compared results between numerical simulation and experiment are consistent fundamentally. This study indicates that the micro-flow rate evaluated from three-dimensional velocity by the scanning micro-PIV technique is a promising method for the micro-flow rate research.

  12. Perceptions of a Gay-Straight Alliance Club Ban: School Counselors and Advocacy for LGBTQQ Students

    Science.gov (United States)

    Lassiter, Pamela S.; Sifford, Amy McCarthy

    2015-01-01

    This phenomenological inquiry explored the experiences and reactions of five school counselors who worked in a school that banned a Gay-Straight Alliance club. Specifically, the authors examined how counselors' perceptions of the ban influenced their advocacy for LGBTQQ students. The results of semi-structured interviews revealed one overarching…

  13. Membranes with highly ordered straight nanopores by selective swelling of fast perpendicularly aligned block copolymers.

    Science.gov (United States)

    Yin, Jun; Yao, Xueping; Liou, Jiun-You; Sun, Wei; Sun, Ya-Sen; Wang, Yong

    2013-11-26

    Membranes with uniform, straight nanopores have important applications in diverse fields, but their application is limited by the lack of efficient producing methods with high controllability. In this work, we reported on an extremely simple and efficient strategy to produce such well-defined membranes. We demonstrated that neutral solvents were capable of annealing amphiphilic block copolymer (BCP) films of polystyrene-block-poly(2-vinylpyridine) (PS-b-P2VP) with thicknesses up to 600 nm to the perpendicular orientation within 1 min. Annealing in neutral solvents was also effective to the perpendicular alignment of block copolymers with very high molecular weights, e.g., 362 000 Da. Remarkably, simply by immersing the annealed BCP films in hot ethanol followed by drying in air, the originally dense BCP films were nondestructively converted into porous membranes containing highly ordered, straight nanopores traversing the entire thickness of the membrane (up to 1.1 μm). Grazing incident small-angle X-ray spectroscopy confirmed the hexagonal ordering of the nanopores over large areas. We found that the overflow of P2VP chains from their reservoir P2VP cylinders and the deformation of the PS matrix in the swelling process contributed to the transformation of the solid P2VP cylinders to empty straight pores. The pore diameters can be tuned by either changing the swelling temperatures or depositing thin layers of metal oxides on the preformed membranes via atomic layer deposition with a subnanometer accuracy. To demonstrate the application of the obtained porous membranes, we used them as templates and produced centimeter-scale arrays of aligned nanotubes of metal oxides with finely tunable wall thicknesses.

  14. Characteristics and determinants of clinical symptoms in radiographic lumbar spinal stenosis in a tertiary health care centre in sub-Saharan Africa.

    Science.gov (United States)

    Doualla-Bija, Marie; Takang, Mbeng Ashu; Mankaa, Emmanuella; Moutchia, Jude; Ongolo-Zogo, Pierre; Luma-Namme, Henry

    2017-11-28

    Lumbar spinal stenosis (LSS) refers to narrowing of the lumbar central spinal canal, lateral recess, and/or neuro-foramina. Radiographic LSS plays an important role in clinical LSS but is not solely accountable for the presence of symptoms. We sought to characterise clinical LSS and to determine factors associated with presence of symptoms of LSS in patients with radiographic LSS in a sub Saharan Africa setting. After prior ethical clearance, a case control study was done in a tertiary hospital in Douala-Cameroon, including 105 patients with radiographic LSS: 57 with symptoms of LSS (cases) and 58 with no symptoms (controls). Spinal stenosis was assessed using computed tomography (CT) scans. Data were analysed using SPSS version 23. The mean age of our study participants was 53.4 ± 13.1 years. The mean age of onset of symptoms of LSS was 50.3 ± 11.6 years and the most common symptoms were Low back pain (100.0%), radicular symptoms (98.2%) and neurogenic claudication (98.2%). Obesity (p history of low back pain (p = 0.004), vertebra lesion at L2 (p = 0.034), L3 (p = 0.002), L4 (p = 0.025) and multiple (p = 0.008) levels, degenerative disc protrusion (p = 0.044), disc lesion at L3-L4 (p = 0.001), L4-L5 (p = 0.011) and multiple (p = 0.046) levels were significantly associated with presence of symptoms of LSS in persons with radiographic LSS. Characteristics of clinical LSS have been described in this sub-Saharan Africa population. Obesity, a high waist circumference and a positive family history of low back pain are significantly associated with presence of symptoms of LSS in persons with radiographic LSS.

  15. How Many Muons Do We Need to Store in a Ring For Neutrino Cross-Section Measurements?

    International Nuclear Information System (INIS)

    Geer, Steve

    2011-01-01

    Analytical estimate of the number of muons that must decay in the straight section of a storage ring to produce a neutrino and anti-neutrino beam of sufficient intensity to facilitate cross-section measurements with a statistical precision of 1%. As we move into the era of precision long-baseline ν μ → ν e and (bar ν) μ → (bar ν) e measurements there is a growing need to precisely determine the ν e and (bar ν) e cross-sections in the relevant energy range, from a fraction of 1 GeV to a few GeV. This will require ν e and (bar ν) e beams with precisely known fluxes and spectra. One way to produce these beams is to use a storage ring with long straight sections in which muon decays (μ - → e - ν μ (bar ν) e if negative muons are stored, and ν + → e + ν e (bar ν) μ if positive muons are stored) produce the desired beam. The challenge is to capture enough muons in the ring to obtain useful neutrino and anti-neutrino fluxes. Early proposals to use a muon storage ring for neutrino oscillation experiments were based upon injecting 'high energy' charged pions into the ring which then decayed to create stored muons. These proposals were hampered by lack of sufficient intensity to pursue the physics. The Neutrino Factory proposal in 1997 was designed to fix this problem by using a Muon Collider class 'low energy' muon source to capture many more pions at low energy, allow them to decay in an external decay channel, manipulate their phase space to capture as many muons as possible within the acceptance of an accelerator, and then accelerate to the energy of choice before injecting into a specially designed ring with long straight sections. All this technology would do a wonderful job in fixing the intensity problem, but at a price that excludes this solution from being realized in the short term. The question that we are now faced with is whether the older, lower intensity 'parasitic' muon storage ring based on 'high energy' pion decays can, with

  16. FEM simulation of a friction testing method based on combined forward conical can-backward straight can extrusion

    DEFF Research Database (Denmark)

    Nakamura, T; Bay, Niels

    1998-01-01

    A new friction testing method based on combined forward conical can-backward straight can extrusion is proposed in order to evaluate friction characteristics in severe metal forming operations. By this method the friction coefficient along the conical punch surface is determined knowing...... the friction coefficient along the die wall. The latter is determined by a combined forward and backward can extrusion of straight cans. Calibration curves determining the relationship between punch travel, can heights, and friction coefficient for the two rests are calculated based on a rigid-plastic FEM...... analysis. Experimental friction tests are carried out in a mechanical press with aluminium alloy A6061 as the workpiece material and different kinds of lubricants. They confirm that the theoretical analysis results irt reasonable values for the friction coefficient....

  17. Heterodyne grating interferometer based on a quasi-common-optical-path configuration for a two-degrees-of-freedom straightness measurement

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ju-Yi; Hsieh, Hung-Lin; Lerondel, Gilles; Deturche, Regis; Lu, Mini-Pei; Chen, Jyh-Chen

    2011-03-20

    We present a heterodyne grating interferometer based on a quasi-common-optical-path (QCOP) design for a two-degrees-of-freedom (DOF) straightness measurement. Two half-wave plates are utilized to rotate the polarizations of two orthogonally polarized beams. The grating movement can be calculated by measuring the phase difference variation in each axis. The experimental results demonstrate that our method has the ability to measure two-DOF straightness and still maintain high system stability. The proposed and demonstrated method, which relies on heterodyne interferometric phase measurement combined with the QCOP configuration, has the advantages of high measurement resolution, relatively straightforward operation, and high system stability.

  18. The construction phase’s influence to the moving ability of cross-sections of woven structure

    Science.gov (United States)

    Inogamdjanov, D.; Daminov, A.; Kasimov, O.

    2017-10-01

    The purpose of this study is to work out bases to predict properties for single layer flat woven fabrics depending on changes of construction phases. A structural model of cross-section of single layered fabric is described based on the Pierce’s model. Form transformation of the yarn like straight, semi-arch and arch yarn is considered according to the alteration of yarn tension under the theory of Novikov. The value contributions to movement index of warp and weft yarn and their total moving ability in cross-sections at all structure phases of fabric are summarized.

  19. Comparison of coupled mode theory and FDTD simulations of coupling between bent and straight optical waveguides

    NARCIS (Netherlands)

    Bertolotti, M.; Symes, W.W.; Stoffer, Remco; Hiremath, K.R.; Driessen, A.; Michelotti, F; Hammer, Manfred

    Analysis of integrated optical cylindrical microresonators involves the coupling between a straight waveguide and a bent waveguide. Our (2D) variant of coupled mode theory is based on analytically represented mode profiles. With the bend modes expressed in Cartesian coordinates, coupled mode

  20. A “Swingable” straight-chain affinity molecule immobilized on a semi-conductor electrode for photo-excited current-based molecular sensing

    International Nuclear Information System (INIS)

    Takatsuji, Yoshiyuki; Wakabayashi, Ryo; Sakakura, Tatsuya; Haruyama, Tetsuya

    2015-01-01

    The molecular affinities of biomolecules have found applications in the areas of clinical diagnostics, drug discovery, as well as allied fields of study. An affinity sensor is a unique in situ assay tool, which is valuable and convenient in practical situations. In this study, we designed a photo-excitable molecular interface with an affinity domain and fabricated with a “swingable” straight-chain affinity molecule immobilized on a semi-conductor electrode (SCE). The straight-chain affinity molecule possessed a photo-excitable dye at one end and was bound to the SCE surface at the other by the EC tag method, which was developed previously. A straight-chain molecule is too long to transfer electrons from the photo-excited dye to the conduction band of the SCE. However, the straight-chain molecule was designed with a “swing” structure, which made the transfer of electrons possible. The central region of the chain molecule has an affinity to the activated estrogen receptor (ER). When the activated ER bound to the affinity region, the molecular lost its swingable function, the electron transfer from the photo-excited dye to the SCE was consequently suppressed. Based on the unique swingable molecular interface, the affinity sensor can be used to determine the in situ concentration of endocrine disrupter ESTROGEN (17β-estradiol) at concentrations ranging from 2 to 10 nM with very good reproducibility. The superior assay reproducibility is responsible for the success of the EC tag method, which is a quantitative method for immobilizing molecules on SCE.

  1. Straight cylindrical seal for high-performance turbomachines

    Science.gov (United States)

    Hendricks, Robert C.

    1987-01-01

    A straight cylindrical seal configuration representing the seal for a high-performance turbopump (e.g., the space shuttle main engine fuel pump) was tested under static (nonrotating) conditions. The test data included critical mass flux and pressure profiles over a wide range of inlet temperatures and pressures for fluid nitrogen and fluid hydrogen with the seal in concentric and fully eccentric positions. The critical mass fluxes (or leakage rates) for the concentric and fully eccentric configurations were nearly the same when based on stagnation conditions upstream of the seal. The fully eccentric configuration pressure profiles of the gas and liquid were different. Further, the pressure differences between the maximum and the minimum clearance positions were highly dependent on the geometric conditions, the temperature, and the absolute pressure at both the inlet and the exit. The pressure differences were greatest in the inlet region. The results, although complex, tend to follow the corresponding-states principles for critical flows. Gaseous injection near the seal exit plane significantly altered the pressure profiles and could be used to control turbomachine instabilities.

  2. Scintillation investigation of the straight back syndrome

    International Nuclear Information System (INIS)

    Ebaid, M.; Serro Azul, L.G.; Kedor, H-H.; Papaleo Netto, M.; Mignone, C.A.; Carvalho, N. de

    1976-01-01

    Scintigraphic study of the lungs was undertaken in 17 patients with the straight back syndrome divided in three groups: I. mild form; II. moderate form and III. severe form. The results showed that: a) there is a decreased flow through the pulmonary arteries; b) bilateral morphological alterations are most common (64.6%); c) the compression of the chest cause an increased cardiac silhouette in groups II (22.2%) and III (50%) besides widening of the mediastinum in all groups (25%, 44.4% and 75%, respectively); d. functional restriction is moderate in 61.5% and severe in 38.4% of the patients in the first two groups; in group III, moderate restriction is observed in 75% of the patients and severe restriction in 25%. Results indicate that the alterations observed in the scintigraphic study of the strainght back syndrome are caused by the effects of the deformed chest on the arterial perfusion of the lung. However, the severity of the anomaly and the decrease in the pulmonary circulation could not be correlated statistically [pt

  3. The active straight leg raising test and mobility of the pelvic joints

    OpenAIRE

    Mens, J. M. A.; Vleeming, Andry; Snijders, Chris J.; Stam, Henk J.; Ginai, Abida Z.

    1999-01-01

    Objective signs to assess impairment in patients who are disabled by peripartum pelvic girdle pain hardly exist. The purpose of this study was to develop a clinical test to quantify and qualify disability in these patients. The study examined the relationship between impaired active straight leg raising (ASLR) and mobility of pelvic joints in patients with peripartum pelvic girdle pain, focusing on (1) the reduction of impairment of ASLR when the patient was wearing a pelvic belt, and (2) mot...

  4. Advantages and disadvantages of straight-lined and nonstraight-lined organizations at the airway facilities training division of the Federal Aviation Administration Academy

    Science.gov (United States)

    McMullen, Jessie L.

    Scope and method of study. This study describes the advantages and the disadvantages of straight-lined and nonstraight-lined organizations at the MMAC FAA Academy. The primary focus will be on the AF division within the FAA Academy. This study will assist in making sound decisions about which structure is better at the present time. Others who read this research will gain an awareness of advantages and disadvantages of each structure. The reason for focusing primarily on individuals from the FAA is because of their experience in straight-line and nonstraight-line organizations. Data were collected during the study and analyzed to determine what the majority of the candidates thought about the structure. Findings and conclusions. Many of the respondents believe the FAA Academy AF Division should be straight-lined to the AFZ organization in Headquarters. Most of the respondents still see the FAA organization as a closed-type structure with a top-down management style. Another important outcome of the findings was many of the respondents believed, regardless of the structure, employees should be empowered more and allowed to participate in the decision-making process. Based on the findings some of the advantages of straight-lined organizations were: it brings the parent organization in and gives them a first hand view of its operations, there is no middle person involved, and there is a direct line to parent organization. The disadvantages of straight-lined organizations based on the findings were: there is no middle management to speak to headquarters as an intermediator on training issues/concerns, it requires more resources and funding that may not be forthcoming, and it compels a parent organization to acquire more resources to handle its own business.

  5. The evolution of stellar metallicity gradients of the Milky Way disk from LSS-GAC main sequence turn-off stars: a two-phase disk formation history?

    International Nuclear Information System (INIS)

    Xiang, Mao-Sheng; Liu, Xiao-Wei; Huang, Yang; Wang, Chun; Ren, Juan-Juan; Chen, Bing-Qiu; Sun, Ning-Chen; Zhang, Hua-Wei; Yuan, Hai-Bo; Rebassa-Mansergas, Alberto; Huo, Zhi-Ying

    2015-01-01

    Accurate measurements of stellar metallicity gradients in the radial and vertical directions of the disk and their temporal variations provide important constraints on the formation and evolution of the Milky Way disk. We use 297 042 main sequence turn-off stars selected from the LAMOST Spectroscopic Survey of the Galactic Anti-center (LSS-GAC) to determine the radial and vertical gradients of stellar metallicity, Δ[Fe/H]/ΔR and Δ[Fe/H]/Δ|Z| of the Milky Way disk in the direction of the anticenter. We determine ages of those turn-off stars by isochrone fitting and measure the temporal variations of metallicity gradients. We have carried out a detailed analysis of the selection effects resulting from the selection, observation and data reduction of LSS-GAC targets and the potential biases of a magnitude limited sample on the determinations of metallicity gradients. Our results show that the gradients, both in the radial and vertical directions, exhibit significant spatial and temporal variations. The radial gradients yielded by stars with the oldest ages (≳ 11 Gyr) are essentially zero at all heights from the disk midplane, while those given by younger stars are always negative. The vertical gradients deduced from stars with the oldest ages (≳ 11 Gyr) are negative and only show very weak variations with Galactocentric distance in the disk plane, R, while those yielded by younger stars show strong variations with R. After being essentially flat at the earliest epochs of disk formation, the radial gradients steepen as age decreases, reaching a maximum (steepest) at age 7–8 Gyr, and then they flatten again. Similar temporal trends are also found for the vertical gradients. We infer that the assembly of the Milky Way disk may have experienced at least two distinct phases. The earlier phase is probably related to a slow, pressure-supported collapse of gas, when the gas settles down to the disk mainly in the vertical direction. In the later phase, there are

  6. Even the Best Have Difficulties: A Study of Finnish Straight-A Graduates' Resource-Oriented Solutions

    Science.gov (United States)

    Salmela, Mari; Määttä, Kaarina

    2015-01-01

    To achieve top scores, students need not only talents and study skills but also they have to conquer various adversities successfully. This research focused on the study paths, the concept adopted from Hickman, Bartholomew, Mathwig, and Heinrich (2008), of Finnish straight-A graduates in general upper secondary education. In this article, we refer…

  7. Offsetting Risks: High School Gay-Straight Alliances and Lesbian, Gay, Bisexual, and Transgender (LGBT) Youth

    Science.gov (United States)

    Heck, Nicholas C.; Flentje, Annesa; Cochran, Bryan N.

    2011-01-01

    Lesbian, gay, bisexual, and transgender (LGBT) youth are at risk for engaging in negative health behaviors and for experiencing at-school victimization. Specific benefits of attending a high school with a gay-straight alliance (GSA), including lower levels of suicidality, have been published; however, it is unclear whether GSAs are related to…

  8. Plastic anisotropy of straight and cross rolled molybdenum sheets

    International Nuclear Information System (INIS)

    Oertel, C.-G.; Huensche, I.; Skrotzki, W.; Knabl, W.; Lorich, A.; Resch, J.

    2008-01-01

    The microstructure, texture and mechanical properties of molybdenum sheets produced by different rolling processes were investigated by orientation imaging in the scanning electron microscope, X-ray diffraction and tensile tests, respectively. For comparable recrystallization degree of the sheets investigated, straight rolling with low reduction ratio produces α-fiber textures with a maximum at {100} . At higher rolling degrees the maximum shifts to {112} . Cross rolling increases the rotated cube component {100} . The strong differences in the texture measured are reflected in the plastic anisotropy characterized by differences in the yield stress and Lankford parameter which were measured along directions in the rolling plane at angles of 0 deg., 45 deg. and 90 deg. with the rolling direction. The Taylor-Bishop-Hill theory is used successfully to qualitatively explain the plastic anisotropy

  9. Application of a drift-flux model to flashing in straight pipes

    International Nuclear Information System (INIS)

    Hirt, C.W.; Romero, N.C.

    1975-06-01

    A new computer program, SOLA-OF, has been written to solve the unsteady, two-dimensional equations of motion for a two-phase mixture. The equations solved are based on the drift-flux approximation and include a phase transition model and a general drift velocity calculation. The SOLA-DF code is used for a study of the blowdown of straight pipes initially filled with water at high temperature and pressure. Computed results are presented that show the relative importance of phase transition rates, pipe friction, drift velocity magnitude, and other model variations. The computed results are also compared with experimental data. 7 references. (auth)

  10. Context based Coding of Binary Shapes by Object Boundary Straightness Analysis

    DEFF Research Database (Denmark)

    Aghito, Shankar Manuel; Forchhammer, Søren

    2004-01-01

    A new lossless compression scheme for bilevel images targeted at binary shapes of image and video objects is presented. The scheme is based on a local analysis of the digital straightness of the causal part of the object boundary, which is used in the context definition for arithmetic encoding....... Tested on individual images of binary shapes and binary layers of digital maps the algorithm outperforms PWC, JBIG and MPEG-4 CAE. On the binary shapes the code lengths are reduced by 21%, 25%, and 42%, respectively. On the maps the reductions are 34%, 32%, and 59%, respectively. The algorithm is also...

  11. Simplified methods for estimating gamma exposure fields transmitted through straight rectangular ducts

    International Nuclear Information System (INIS)

    Shultis, J.K.; Thompson, K.R.; Faw, R.E.

    1986-01-01

    Approximate computational models are developed to describe the spatial variation in the radiation field transmitted through a straight reactangular duct obliquely illuminated by monoenergetic gamma photons. These models account for single and multiple scattering from the duct walls and lips as well as for direct penetration by the photons. Results of calculations are compared to results from a recent benchmark duct streaming experiment, and empirical correction factors are obtained which enable the models to predict the transmitted exposure rates to within 20% of the experimental values

  12. Implementing Lean Six Sigma in organizations

    NARCIS (Netherlands)

    Lameijer, B.A.

    2017-01-01

    This thesis focuses on operational excellence following the Lean Six Sigma (LSS) method. As the popularity of implementing LSS grows, questions about implementing LSS in organizations arise, and this is where we aim to contribute. We study key questions about implementing LSS in organizations at two

  13. Numerical investigation of heat transfer and entropy generation of laminar flow in helical tubes with various cross sections

    International Nuclear Information System (INIS)

    Kurnia, Jundika C.; Sasmito, Agus P.; Shamim, Tariq; Mujumdar, Arun S.

    2016-01-01

    Highlights: • Heat transfers of helical coiled tube with several cross section profiles are evaluated. • Helical tubes offer higher heat transfer and lower entropy generation. • Square cross-section generates the highest entropy, followed by ellipse and circular. • Study could serve as a guideline in designing an efficient helical tube heat exchanger. - Abstract: This study evaluates heat transfer performance and entropy generation of laminar flow in coiled tubes with various cross-sections geometries i.e. circular, ellipse and square, relatives to the straight tubes of similar cross-sections. A computational fluid dynamics model is developed and validated against empirical correlations. Good agreement is obtained within range of Reynolds and Dean numbers considered. Effect of geometry, wall temperature, Reynolds number and heating/cooling mode were examined. To evaluate the heat transfer performance of the coiled tube configurations, a parameter referred as Figure of Merit (FoM) is defined as the ratio heat transfer rate to the required pumping power. In addition, exergy analysis is carried out to examine the inefficiency of the coiled tube configurations. The results indicate that coiled tubes provide higher heat transfer rate. In addition, it was found to be more efficient as reflected by lower entropy generation as compared to straight tubes. Among the studied cross-section, square cross-section generates the highest entropy, followed by ellipse and circular counterpart. Entropy production from heat transfer contribution is two order-of-magnitude higher than that of entropy contribution from viscous dissipation. Cooling case produces slightly higher entropy than heating counterpart. Finally, this study can provide practical guideline to design more efficient coiled heat exchanger.

  14. Extension of Ko Straight-Beam Displacement Theory to Deformed Shape Predictions of Slender Curved Structures

    Science.gov (United States)

    Ko, William L.; Fleischer, Van Tran

    2011-01-01

    The Ko displacement theory originally developed for shape predictions of straight beams is extended to shape predictions of curved beams. The surface strains needed for shape predictions were analytically generated from finite-element nodal stress outputs. With the aid of finite-element displacement outputs, mathematical functional forms for curvature-effect correction terms are established and incorporated into straight-beam deflection equations for shape predictions of both cantilever and two-point supported curved beams. The newly established deflection equations for cantilever curved beams could provide quite accurate shape predictions for different cantilever curved beams, including the quarter-circle cantilever beam. Furthermore, the newly formulated deflection equations for two-point supported curved beams could provide accurate shape predictions for a range of two-point supported curved beams, including the full-circular ring. Accuracy of the newly developed curved-beam deflection equations is validated through shape prediction analysis of curved beams embedded in the windward shallow spherical shell of a generic crew exploration vehicle. A single-point collocation method for optimization of shape predictions is discussed in detail

  15. PHYSICAL AND CHEMICAL PROPERTIES AND STRUCTURAL-GROUP COMPOSITION OF STRAIGHT-RUN FRACTIONS OF IRAQI OILFIELDS

    Directory of Open Access Journals (Sweden)

    С.В. Бойченко

    2012-10-01

    Full Text Available  Iraq is one of the richest countries of the Near East in terms of oil reserves. Only Saudi Arabia has greater hydrocarbon reserves. Despite the fact that commercial oil production is implemented since 1927, the harsh social and political and economic situation added with long-time military conflict had totally destroyed           oil processing infrastructure. Considering this factor, one of the key tasks for this country is building of  a new, contemporary oil processing infrastructure. Thus, complex study of oils as well as their  straight-run fractions is a requirement for preparation of the projects of oil processing plants that are consistent with current hard requirements. This material contents results of physical and chemical studies  of straight-run oil fractions as gasoline, Diesel oil, and heavy oils. Properties of fractions shown below, their potential related to export oil products are essential data for preparation of process flow diagram of the oil processing plant.

  16. A Closed-Form Error Model of Straight Lines for Improved Data Association and Sensor Fusing

    Directory of Open Access Journals (Sweden)

    Volker Sommer

    2018-04-01

    Full Text Available Linear regression is a basic tool in mobile robotics, since it enables accurate estimation of straight lines from range-bearing scans or in digital images, which is a prerequisite for reliable data association and sensor fusing in the context of feature-based SLAM. This paper discusses, extends and compares existing algorithms for line fitting applicable also in the case of strong covariances between the coordinates at each single data point, which must not be neglected if range-bearing sensors are used. Besides, in particular, the determination of the covariance matrix is considered, which is required for stochastic modeling. The main contribution is a new error model of straight lines in closed form for calculating quickly and reliably the covariance matrix dependent on just a few comprehensible and easily-obtainable parameters. The model can be applied widely in any case when a line is fitted from a number of distinct points also without a priori knowledge of the specific measurement noise. By means of extensive simulations, the performance and robustness of the new model in comparison to existing approaches is shown.

  17. Implicit Preferences for Straight People over Lesbian Women and Gay Men Weakened from 2006 to 2013

    Directory of Open Access Journals (Sweden)

    Erin C Westgate

    2015-07-01

    Full Text Available Legal rights and cultural attitudes towards lesbian women and gay men have shifted rapidly in the early 21st century. Using 683,976 visitors to Project Implicit from February 2006 to August 2013, we investigated whether shifts were also observable in implicit evaluations that occur outside of conscious awareness or control. Similar to public opinion polling, the estimated explicit preference for straight people over lesbian women and gay men was 26% weaker on the last day compared to the first. The estimated implicit preference for straight people declined by 13.4% over the same period. The largest shifts in implicit evaluations occurred among Hispanic, White, female, liberal, and young adult participants; the smallest shifts occurred among Black, Asian, male, conservative, and older adult participants. Societal change in evaluation of lesbian and gay people is not limited to what people are willing and able to report. However, change in implicit evaluation appears to be slower.

  18. Youth empowerment and high school Gay-Straight Alliances.

    Science.gov (United States)

    Russell, Stephen T; Muraco, Anna; Subramaniam, Aarti; Laub, Carolyn

    2009-08-01

    In the field of positive youth development programs, "empowerment" is used interchangeably with youth activism, leadership, civic participation and self-efficacy. However, few studies have captured what empowerment means to young people in diverse contexts. This article explores how youth define and experience empowerment in youth-led organizations characterized by social justice goals: high school Gay-Straight Alliances (GSAs). Through focus group interviews, fifteen youth leaders of GSAs from different regions of California explain what they think empowerment means and how they became empowered through their involvement with the GSA. Youth describe three inter-related dimensions of empowerment: personal empowerment, relational empowerment, and strategic empowerment through having and using knowledge. When these three dimensions are experienced in combination, GSA leaders have the potential for individual and collective empowerment as agents of social change at school. By understanding these youth's perspectives on the meanings of empowerment, this article clarifies the conceptual arena for future studies of socially marginalized youth and of positive youth development.

  19. Youth Empowerment and High School Gay-Straight Alliances

    Science.gov (United States)

    Muraco, Anna; Subramaniam, Aarti; Laub, Carolyn

    2010-01-01

    In the field of positive youth development programs, “empowerment” is used interchangeably with youth activism, leadership, civic participation and self-efficacy. However, few studies have captured what empowerment means to young people in diverse contexts. This article explores how youth define and experience empowerment in youth-led organizations characterized by social justice goals: high school Gay-Straight Alliances (GSAs). Through focus group interviews, fifteen youth leaders of GSAs from different regions of California explain what they think empowerment means and how they became empowered through their involvement with the GSA. Youth describe three inter-related dimensions of empowerment: personal empowerment, relational empowerment, and strategic empowerment through having and using knowledge. When these three dimensions are experienced in combination, GSA leaders have the potential for individual and collective empowerment as agents of social change at school. By understanding these youth's perspectives on the meanings of empowerment, this article clarifies the conceptual arena for future studies of socially marginalized youth and of positive youth development. PMID:19636734

  20. Effect of Lathyrus sativus and vitamin C on the status of aromatic L-amino acid decarboxylase and dipeptidyl-aminopeptidase-IV in the central and peripheral tissues and serum of guinea pigs

    International Nuclear Information System (INIS)

    Rahman, M.K.; Sarker, M.A.H.

    1992-05-01

    Studies on the effect of Lathyrus Sativus seeds (LLS) on aromatic L-amino acid decarboxylase (AADC) and on dipeptidyl-aminopeptidase-IV (DAP-IV) were carried out in the central and peripheral tissues and serum of LSS-treated and LSS plus vitamin C-treated guinea pigs. The feeding of LSS for 35 days decreased the AADC activity significantly in the brain and peripheral tissues, but the activity was recovered to normal level in the most tissues when vitamin C was added with the LSS. DAP-IV activity decreased in the peripheral tissues when treated with LSS, but the vitamin C administration with LSS did not recover the enzyme activity. The DAP-IV activity did not decrease significantly in any of the brain tissues of the LSS-treated group. (author). 18 refs, 2 tabs

  1. 50 CFR Figures 14a and 14b to Part... - Maximum Angle of Deflector Bars With Straight Bars Attached to the Bottom of the Frame and...

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Maximum Angle of Deflector Bars With Straight Bars Attached to the Bottom of the Frame and Maximum Angle of Deflector Bars With Bent Bars... 223—Maximum Angle of Deflector Bars With Straight Bars Attached to the Bottom of the Frame and Maximum...

  2. Possibility of whole-surface analysis of a silicon wafer with ordinary straight TXRF

    International Nuclear Information System (INIS)

    Mori, Y.; Uemura, K.; Iizuka, Y.

    2000-01-01

    For the analysis of average metal concentration on a semiconductor surface, we customarily use the wet techniques (AAS, typically), that require skilled operators or expensive automated machines for sample pretreatment. The straight TXRF require no pretreatment, on the other hand. However, its detection area is too small (1-2 cm 2 ) to conduct a whole-surface analysis. In fact, it takes more than one day per one wafer (500 s/point x 100-300 points) for a complete mapping. Therefore it has been believed that the whole-surface analysis with straight TXRF is impracticable. It should be noted that the absolute lower limit of detection (LLD) of the straight TXRF is superior to AAS. As an example, the absolute LLD of TXRF for Fe is 0.2 pg (500 s integration), while that of AAS is l0 pg. The required integration time for TXRF to obtain the same LLD of AAS is calculated to be only 0.2 s. This means, in principle, that the whole-surface contamination can be measured in some ten seconds by accumulating 0.2 s mapping. But actually, the adjustment of glancing angle requires several ten seconds per one point, so the above mapping still takes several hours. That is why such a measurement has not been applied to daily analysis so far. However, the influence of glancing angle errors is expected to be reduced through the multi-point measurement. Figure 1 shows an accumulated spectrum of 20 s x 25 points mapping for an IAP wafer doped with Ni. In this measurement, glancing angles were not precisely controlled (the error of glancing angle is ±15 %). A spectrum of 500 s x 1 point measurement for the same wafer is shown in Figure 2. Figures 1 and 2 are almost identical. This suggests that the reduction of glancing angle errors actually works well through multi-points measurement. This method is expected to give better results by increasing the number of measuring points. The overall variation for the final measurement value obtained by multi-point measurement can be assessed by the

  3. Gay-Straight Alliances in the Battle for Rights: A Tipping Point for Progress over Prohibition

    Science.gov (United States)

    Sinclair, James; Reece, Brian J.

    2016-01-01

    This is a brief essay on the oppressive natures of school and the rights of students to arm themselves with the creation of Gay-Straight Alliances (GSAs). Students who identify as LGBTQ are at higher risk for victimization, among other negative outcomes. For those who identify as LGBTQ, GSAs are often a safe-haven from the heteronormative…

  4. Contextualizing Gay-straight Alliances: Student, Advisor, and Structural Factors Related to Positive Youth Development among Members

    Science.gov (United States)

    Poteat, V. Paul; Yoshikawa, Hirokazu; Calzo, Jerel P.; Gray, Mary L.; DiGiovanni, Craig D.; Lipkin, Arthur; Mundy-Shephard, Adrienne; Perrotti, Jeff; Scheer, Jillian R.; Shaw, Matthew P.

    2015-01-01

    Gay-straight alliances (GSAs) may promote resilience. Yet, what GSA components predict well-being? Among 146 youth and advisors in 13 GSAs (58% lesbian, gay, bisexual, or questioning; 64% White; 38% received free/reduced-cost lunch), student (demographics, victimization, attendance frequency, leadership, support, control), advisor (years served,…

  5. Flow in curved ducts of varying cross-section

    Science.gov (United States)

    Sotiropoulos, F.; Patel, V. C.

    1992-07-01

    Two numerical methods for solving the incompressible Navier-Stokes equations are compared with each other by applying them to calculate laminar and turbulent flows through curved ducts of regular cross-section. Detailed comparisons, between the computed solutions and experimental data, are carried out in order to validate the two methods and to identify their relative merits and disadvantages. Based on the conclusions of this comparative study a numerical method is developed for simulating viscous flows through curved ducts of varying cross-sections. The proposed method is capable of simulating the near-wall turbulence using fine computational meshes across the sublayer in conjunction with a two-layer k-epsilon model. Numerical solutions are obtained for: (1) a straight transition duct geometry, and (2) a hydroturbine draft-tube configuration at model scale Reynolds number for various inlet swirl intensities. The report also provides a detailed literature survey that summarizes all the experimental and computational work in the area of duct flows.

  6. Experimental evaluation of J in cracked straight and curved pipes under bending

    International Nuclear Information System (INIS)

    Moulin, D.; Touboul, F.; Foucher, N.; Lebey, J.; Acker, D.

    1989-01-01

    An experimental program is being carried out at the CEA Saclay in collaboration with FRAMATOME and IPSN with a view to validate analysis methods applicable for evaluation of leak before break behavior in P.W.R. piping. A large experimental work was already performed in USA, Germany and Japan and cracked pipes made of stainless steel material under bending. The methods of analysis got same validations for straight pipes. However applicability to elbows and comparison with toughness values obtained on small specimens like CT specimens was not completely dealt with

  7. Process for the selective cracking of straight-chained and slightly branched hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Gorring, R L; Shipman, G F

    1975-01-23

    The invention describes a method for the selective (hydro) cracking of petroleum materials, containing normal straight-chained and/or slightly branched-chained hydrocarbons. The mixture is brought into contact with a selective, crystalline alumino silicate zeolite cracking catalyst housing a silicon oxide/aluminum oxide ratio of at least about 12 and a constraint index of about 1 to 12 under cracking conditions. A zeolite catalyst with a crystal size of up to 0.05 ..mu.. is used. Solidification point and viscosity in particular of oils are to be lowered through the catalytic dewaxing.

  8. [Difference of anti-fracture mechanical characteristics between lateral-root branches and adjacent upper straight roots of four plant species in vigorous growth period].

    Science.gov (United States)

    Liu, Peng-fei; Liu, Jing; Zhu, Hong-hui; Zhang, Xin; Zhang, Ge; Li, You-fang; Su, Yu; Wang, Chen-jia

    2016-01-01

    Taking four plant species, Caragana korshinskii, Salix psammophila, Hippophae rhamnides and Artemisia sphaerocephala, which were 3-4 years old and in vigorous growth period, as test materials, the anti-fracture forces of lateral-root branches and adjacent upper straight roots were measured with the self-made fixture and the instrument of TY 8000. The lateral-root branches were vital and the diameters were 1-4 mm. The results showed that the anti-fracture force and anti-fracture strength of lateral-root branches were lesser than those of the adjacent upper straight roots even though the average diameter of lateral-root branches was greater. The ratios of anti-fracture strength of lateral-root branches to the adjacent upper straight roots were 71.5% for C. korshinskii, 62.9% for S. psammophila, 45.4% for H. rhamnides and 35.4% for A. sphaerocephala. For the four plants, the anti-fracture force positively correlated with the diameter in a power function, while the anti-fracture strength negatively correlated with diameter in a power function. The anti-fracture strengths of lateral-root branches and adjacent upper straight roots for the four species followed the sequence of C. korshinskii (33.66 and 47.06 MPa) > S. psammophila (17.31 and 27.54 MPa) > H. rhamnides (3.97 and 8.75 MPa) > A. sphaerphala (2.18 and 6.15 MPa).

  9. Power spectrum weighted edge analysis for straight edge detection in images

    Science.gov (United States)

    Karvir, Hrishikesh V.; Skipper, Julie A.

    2007-04-01

    Most man-made objects provide characteristic straight line edges and, therefore, edge extraction is a commonly used target detection tool. However, noisy images often yield broken edges that lead to missed detections, and extraneous edges that may contribute to false target detections. We present a sliding-block approach for target detection using weighted power spectral analysis. In general, straight line edges appearing at a given frequency are represented as a peak in the Fourier domain at a radius corresponding to that frequency, and a direction corresponding to the orientation of the edges in the spatial domain. Knowing the edge width and spacing between the edges, a band-pass filter is designed to extract the Fourier peaks corresponding to the target edges and suppress image noise. These peaks are then detected by amplitude thresholding. The frequency band width and the subsequent spatial filter mask size are variable parameters to facilitate detection of target objects of different sizes under known imaging geometries. Many military objects, such as trucks, tanks and missile launchers, produce definite signatures with parallel lines and the algorithm proves to be ideal for detecting such objects. Moreover, shadow-casting objects generally provide sharp edges and are readily detected. The block operation procedure offers advantages of significant reduction in noise influence, improved edge detection, faster processing speed and versatility to detect diverse objects of different sizes in the image. With Scud missile launcher replicas as target objects, the method has been successfully tested on terrain board test images under different backgrounds, illumination and imaging geometries with cameras of differing spatial resolution and bit-depth.

  10. Duration of load behaviour of different sized straight timber beams subjected to bending in variable climate

    DEFF Research Database (Denmark)

    Hanhijärvi, A.; Galimard, P.; Hoffmeyer, Preben

    1998-01-01

    The paper is the second in a series which sums up the results of an extensive project to quantify the duration-of-load (DOL) effect on different sized timber beams in different climates. The paper deals with straight (unnotched) beams. The results of various DOL-tests of stepwise and constant...

  11. Challenging the Sounds of Silence: A Qualitative Study of Gay-Straight Alliances and School Reform Efforts

    Science.gov (United States)

    Mayberry, Maralee; Chenneville, Tiffany; Currie, Sean

    2013-01-01

    We explore the efficacy of one increasingly familiar strategic intervention designed to disrupt antigay school environments--Gay-Straight Alliances (GSAs). Despite the increasing popularity of GSAs, there has been little research on the ways in which they do--and do not--impact school climate. The ubiquity of antigay and homophobic attitudes…

  12. Failure of the straight-line DCS boundary when extrapolated to the hypobaric realm.

    Science.gov (United States)

    Conkin, J; Van Liew, H D

    1992-11-01

    The lowest pressure (P2) to which a diver can ascend without developing decompression sickness (DCS) after becoming equilibrated at some higher pressure (P1) is described by a straight line with a negative y-intercept. We tested whether extrapolation of such a line also predicts safe decompression to altitude. We substituted tissue nitrogen pressure (P1N2) calculated for a compartment with a 360-min half-time for P1 values; this allows data from hypobaric exposures to be plotted on a P2 vs. P1N2 graph, even if the subject breathes oxygen before ascent. In literature sources, we found 40 reports of human exposures in hypobaric chambers that fell in the region of a P2 vs. P1N2 plot where the extrapolation from hyperbaric data predicted that the decompression should be free of DCS. Of 4,576 exposures, 785 persons suffered decompression sickness (17%), indicating that extrapolation of the diver line to altitude is not valid. Over the pressure range spanned by human hypobaric exposures and hyperbaric air exposures, the best separation between no DCS and DCS on a P2 vs. P1N2 plot seems to be a curve which approximates a straight line in the hyperbaric region but bends toward the origin in the hypobaric region.

  13. Comparison of Colonic J-pouch and Straight Coloanal anastomosis after Low Anterior Resection.

    Science.gov (United States)

    Mehrvarz, Shaban; Towliat, Seyed Mohsen; Mohebbi, Hassan Ali; Derakhshani, Saieed; Abavisani, Mahdi

    2013-01-01

    The tendency towards sphincter preserving for low rectal cancers with low anterior resection, has led to the technique of straight coloanal anastomosis (SCAA) or colonic J-pouch anal anastomosis (CPAA). The aim of our study was to compare functional outcomes, complication rates and quality of life (QoL) after LAR with either a straight or colonic J pouch anastomosis. In 88 patients with rectal tumors located in lower third, who were candidate for LAR with coloanal anastomosis. They were divided for reconstruction using either SCAA (n= 47) or CPAA (n= 41) from January 2007 to May 2009. Functional results were assessed after closure of temporary loop ileostomy, 6 months postoperatively. Quality of life (QoL) was measured using European Organization for Research and Treatment of Cancer (EORTC) QLQ-C30. The two groups were matched for gender, age, and preoperative chemotherapy and radiotherapy. There were no significant differences between the SCAA and CPAA groups relative to anastomotic leakage. Among patients with CPAA, the mean of 24 hours bowel movements, daytime bowel movements, incontinence scores, and incidence of urgency were significantly lower than those in the SCAA group. Also, patients with a CPAA had a significantly better quality of life. CPAA provided not only better functional results than SCAA, but also improved quality of life, thus may be the better choice.

  14. A Method to Establishing Tube Plugging Criterion for Heat Exchangers with Straight Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyungnam [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    The difference of thermal expansion coefficients between the shell and tube materials causes the stress in axial direction of tube. Because of the axial stress due to thermal load, the straight tubes are used for heat exchangers operated in low temperature such as CCW (Component Cooling Water) heat exchangers and condensers. It is inevitable for the materials of the components to be degraded as the power plants become older. The degradation accompanies increasing maintenance cost as well as creating safety issues. The materials and wall thickness of heat exchanger tubes in nuclear power plants are selected to withstand system temperature, pressure, and corrosion. There are many codes and standards to be referred for calculating the minimum thickness of the heat exchanger tube in the designing stage. However, the codes and standards related to show the tube plugging criteria may not exist currently. In this paper, a method to establish the tube plugging criteria of BOP heat exchangers, which is based on the USNRC Regulatory Guide 1.121, is introduced and the tube plugging criteria for the TPCCW heat exchanger of Yonggwang NPP No. 1 and 2. A method to establish the tube plugging criteria of heat exchangers with straight tubes are introduced based on the USNRC Regulatory Guide 1.121. As an example, the tube plugging criterion for the CCW heat exchanger of a nuclear power plant is provided.

  15. Numerical-Model Investigation of the Hydrothermal Regime of a Straight-Through Shallow Cooling Pond

    Energy Technology Data Exchange (ETDEWEB)

    Sokolov, A. S. [JSC ' VNIIG im. B. E. Vedeneeva' (Russian Federation)

    2013-11-15

    A mathematic model based on solution of hydrodynamics and heat-transfer equations by the finite-element method is constructed to predict the hydrothermal regime of a straight-through shallow cooling pond, which provides cooling circulating water to a repository of spent nuclear fuel. Numerical experiments made it possible to evaluate the influence exerted by wind conditions and flow rate of water in the river on the temperature of the circulating water.

  16. Radiation-induced desulfurization of Arabian crude oil and straight-run diesel

    Science.gov (United States)

    Basfar, A. A.; Mohamed, K. A.

    2011-11-01

    Radiation-induced desulfurization of four types of Arabian crude oils (heavy, medium, light and extra light) and straight-run diesel (SRD) was investigated over the range of 10-200 kGy. Results show that gamma radiation processing at absorbed doses up to 200 kGy without further treatment is not sufficient for desulfurization. However, the combination of gamma-irradiation with other physical/chemical processes (i.e. L/L extraction, adsorption and oxidation) may be capable of removing considerable levels of sulfur compounds in the investigated products. Currently, this approach of combined radiation/physical/chemical processes is under investigation. The findings of these attempts will be reported in the future.

  17. Inertio-elastic mixing in a straight microchannel with side wells

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sun Ok [Department of Energy Systems Research, Ajou University, Suwon 443-749 (Korea, Republic of); Cooper-White, Justin J. [Tissue Engineering and Microfluidics Laboratory, The Australian Institute for Bioengineering and Nanotechnology, University of Queensland, St Lucia, 4072 QLD (Australia); School of Chemical Engineering, University of Queensland, St Lucia, 4072 QLD (Australia); CSIRO, Manufacturing Flagship, Clayton, 3169 Victoria (Australia); Kim, Ju Min, E-mail: jumin@ajou.ac.kr [Department of Energy Systems Research, Ajou University, Suwon 443-749 (Korea, Republic of); Department of Chemical Engineering, Ajou University, Suwon 443-749 (Korea, Republic of)

    2016-01-04

    Mixing remains a challenging task in microfluidic channels because of their inherently small length scale. In this work, we propose an efficient microfluidic mixer based on the chaotic vortex dynamics of a viscoelastic flow in a straight channel with side wells. When the inertia and elasticity of a dilute polymer solution are balanced (i.e., the Reynolds number Re and Weissenberg number Wi are both on the order of 10{sup 1}), chaotic vortices appear in the side wells (inertio-elastic flow instability), enhancing the mixing of adjacent fluid streams. However, there is no chaotic vortex motion in Newtonian flows for any flow rate. Efficient mixing by such an inertio-elastic instability is found to be relevant for a wide range of Re values.

  18. Growth, straightness and survival at age 32 in a Pinus strobus x P. wallichiana F1 hybrid population (Experiment 1

    Directory of Open Access Journals (Sweden)

    Ioan Blada

    2013-11-01

    Full Text Available An interspecific factorial hybridization was made, where seven P. strobus female parent trees were mated to four P. wallichiana male trees, in order to transfer genes for resistance to blister-rust from the blue pine to the F1 hybrids. The hybrid seedlings and the open pollinated families of the two parents were three times consecutivelyinoculated with blister-rust. The six years old seedlings were transplanted in the field in the so called Văliug Experiment 1. The experimental design consisted in 28 hybrid full-sib families and two open pollinated families of the parent species. Plantation took place in a complete randomized block design with three blocks, with 6 to 12 seedlings per linear plot and 3 x 3 m spacing. This paper is based on the measurements made at age 32, just after the first thinning. Diameter at breast height, tree height, tree volume, stem straightness and tree survival were the five measured traits. According to ANOVA, significant (p < 0.05 and highly significant (p< 0.001 differences for diameter at breast height, tree height, volume growth rate, stem straightness and tree survival were detected between hybrid families. Highly significant (p < 0.01, p < 0.001 differences were found between eastern white pine female parents for survival, stem straightness and all growth traits, suggestingthat nuclear additive genes are controlling the respective characters. Consequently, high survival or genetic resistance to blister-rust can be found within the P. strobus species even though it is highly susceptible to this pathogen. The P. wallichiana parents exhibited significant additive effects on straightness and breast height diameter, but no significance in height, volume, and tree survival. The contribution of the additive variance to the phenotypic one was 65.7% for diameter, 58.6% for height, 50.5% for volume, 70.4% for stem straightness and 73.4% for tree survival. Hence, additive variance should be employed in a breeding program

  19. LGBTQ Youth's Views on Gay-Straight Alliances: Building Community, Providing Gateways, and Representing Safety and Support

    Science.gov (United States)

    Porta, Carolyn M.; Singer, Erin; Mehus, Christopher J.; Gower, Amy L.; Saewyc, Elizabeth; Fredkove, Windy; Eisenberg, Marla E.

    2017-01-01

    Background: Gay-Straight Alliances (GSAs) are school-based clubs that can contribute to a healthy school climate for lesbian, gay, bisexual, transgender, and questioning (LGBTQ) youth. While positive associations between health behaviors and GSAs have been documented, less is known about how youth perceive GSAs. Methods: A total of 58 LGBTQ youth…

  20. Prevention of Dental Damage and Improvement of Difficult Intubation Using a Paraglossal Technique With a Straight Miller Blade

    Directory of Open Access Journals (Sweden)

    Yu-Feng Huang

    2010-10-01

    Full Text Available Patients with diseased teeth, or those who are difficult to intubate, have a higher risk of dental injury during laryngoscopy. We report 3 cases of smooth endotracheal intubation using a paraglossal technique with a straight Miller blade in patients with poor dentition. Three patients with poor dentition were scheduled to undergo surgery under general anesthesia. All patients presented with extremely loose upper central incisors and had lost the other right upper teeth, while micrognathia and prominent, loose upper incisors were noted in 1 case. We elected to use a straight Miller blade using a paraglossal approach. A nasopharyngeal airway was inserted after induction of general anesthesia to facilitate mask ventilation and prevent air leakage from the mask. The Miller blade was then inserted from the right corner of the mouth, avoiding contact with the vulnerable incisors, and advanced along the groove between the tongue and tonsil. The endotracheal tube was subsequently smoothly inserted after obtaining a grade 1 Cormack and Lehane view without dental trauma in all 3 cases. Direct laryngoscopy using the paraglossal straight blade technique avoids dental damage in patients with mobile upper incisors and no right maxillary molars. It is a practical alternative method that differs from the traditional Macintosh laryngoscope in patients with a high risk of dental injury during the procedure. This technique, which provides an improved view of the larynx, might also be helpful with patients in whom intubation is difficult.

  1. Diffraction of a Gaussian laser beam by a straight edge leading to the formation of optical vortices and elliptical diffraction fringes

    Science.gov (United States)

    Zeylikovich, Iosif; Nikitin, Aleksandr

    2018-04-01

    The diffraction of a Gaussian laser beam by a straight edge has been studied theoretically and experimentally for many years. In this paper, we have experimentally observed for the first time the formation of the cusped caustic (for the Fresnel number F ≈ 100) in the shadow region of the straight edge, with the cusp placed near the center of the circular laser beam(λ = 0 . 65 μm) overlapped with the elliptical diffraction fringes. These fringes are originated at the region near the cusp of the caustic where light intensity is zero and the wave phase is singular (the optical vortex). We interpret observed diffraction fringes as a result of interference between the helical wave created by the optical vortex and cylindrical wave diffracted at the straight edge. We have theoretically revealed that the number of high contrast diffraction fringes observable in a shadow region is determined by the square of the diffracted angles in the range of spatial frequencies of the scattered light field in excellent agreement with experiments. The extra phase singularities with opposite charges are also observed along the shadow boundary as the fork-like diffraction fringes.

  2. Flow instability research on steam generator with straight double-walled heat transfer tube for FBR. Pressure drop under high pressure condition

    International Nuclear Information System (INIS)

    Liu, Wei; Tamai, Hidesada; Yoshida, Hiroyuki; Takase, Kazuyuki; Hayafune, Hiroki; Futagami, Satoshi; Kisohara, Naoyuki

    2008-01-01

    For the Steam Generator (SG) with straight double-walled heat transfer tube that used in sodium cooled Faster Breeder Reactor, flow instability is one of the most important items need researching. As the first step of the research, thermal hydraulics experiments were performed under high pressure condition in JAEA with using a straight tube. Pressure drop, heat transfer coefficients and void fraction data were derived. This paper evaluates the pressure drop data with TRAC-BF1 code. The Pffan's correlation for single phase flow and the Martinelli-Nelson's two-phase flow multiplier are found can be well predicted the present pressure drop data under high pressure condition. (author)

  3. Application of a cellular automaton for recognition of straight tracks in the spectrometer DISTO

    International Nuclear Information System (INIS)

    Bussa, M.P.; Fava, L.; Ferrero, L.; Grasso, A.; Ivanov, V.V.; Kisel', I.V.; Konotopskaya, E.V.; Pontecorvo, G.B.

    1995-01-01

    A model of the cellular automaton for recognition of straight tracks has been developed. The program realization of this algorithm has shown high efficiency and speed for the simulated data for the experiment DISTO. Its working speed provides for the processing of approximately 1000 events/sec using the 50 MIPS RISC-processor. This makes suitable its application for track recognition in the second level trigger of the DISTO spectrometer. 10 refs., 7 figs., 1 tab

  4. The Effects of a Remote Atoll and Lagoon on the Marine Boundary Layer

    Science.gov (United States)

    2012-12-01

    12:34 1 FVS (53),1 FFM (71), 2 LSS (229) at 10000’, 1 LSS (106) at 25000’, OH (117) 49 46/4 20111116 Large-scale Moisture variability and...D), Dropsondes near SPol 04:06 - 13:02 1 FFM (56), 1 RCE (43), 3 MP (14), 1 LSS (97) at 10000’, 3 LSS at 25000’ (114), 1 FD (16), 1 Gan...FVS (65), 1 FFM (68), 2 LSS at 10000’ (248), 2 FD (35), 1 RB (32), 1 SI (40), OH (106) 33 37/21 22 20111128 Wind and thermodynamics

  5. Desirable airfoil features for smaller-capacity straight-bladed VAWT

    Energy Technology Data Exchange (ETDEWEB)

    Islam, Mazharul; Ting, D.S.-K.; Fartaj, Amir

    2007-05-15

    In the small scale wind turbine market, the simple straight-bladed Darrieus type vertical axis wind turbine (SB-VAWT) is very attractive for its simple blade design. A detailed aerodynamic performance analysis was conducted on a smaller capacity fixed-pitch SB-VAWT. Brief analyses of the main aerodynamic challenges of this type of wind turbine were first discussed and subsequently the authors conducted further literature survey and computational analysis to shortlist aerodynamic characteristics of a desirable airfoil for a self-starting and better performing SB-VAWT. The required geometric features of the desirable airfoil to achieve the short listed characteristics were also discussed. It has been found out that conventionally used NACA symmetric airfoils are not suitable for smaller capacity SB-VAWT. Rather, it is advantageous to utilize a high-lift and low-drag asymmetric thick airfoil suitable for low speed operation typically encountered by SB-VAWT. (author)

  6. Origami tubes with reconfigurable polygonal cross-sections.

    Science.gov (United States)

    Filipov, E T; Paulino, G H; Tachi, T

    2016-01-01

    Thin sheets can be assembled into origami tubes to create a variety of deployable, reconfigurable and mechanistically unique three-dimensional structures. We introduce and explore origami tubes with polygonal, translational symmetric cross-sections that can reconfigure into numerous geometries. The tubular structures satisfy the mathematical definitions for flat and rigid foldability, meaning that they can fully unfold from a flattened state with deformations occurring only at the fold lines. The tubes do not need to be straight and can be constructed to follow a non-linear curved line when deployed. The cross-section and kinematics of the tubular structures can be reprogrammed by changing the direction of folding at some folds. We discuss the variety of tubular structures that can be conceived and we show limitations that govern the geometric design. We quantify the global stiffness of the origami tubes through eigenvalue and structural analyses and highlight the mechanical characteristics of these systems. The two-scale nature of this work indicates that, from a local viewpoint, the cross-sections of the polygonal tubes are reconfigurable while, from a global viewpoint, deployable tubes of desired shapes are achieved. This class of tubes has potential applications ranging from pipes and micro-robotics to deployable architecture in buildings.

  7. Origami tubes with reconfigurable polygonal cross-sections

    Science.gov (United States)

    Filipov, E. T.; Paulino, G. H.; Tachi, T.

    2016-01-01

    Thin sheets can be assembled into origami tubes to create a variety of deployable, reconfigurable and mechanistically unique three-dimensional structures. We introduce and explore origami tubes with polygonal, translational symmetric cross-sections that can reconfigure into numerous geometries. The tubular structures satisfy the mathematical definitions for flat and rigid foldability, meaning that they can fully unfold from a flattened state with deformations occurring only at the fold lines. The tubes do not need to be straight and can be constructed to follow a non-linear curved line when deployed. The cross-section and kinematics of the tubular structures can be reprogrammed by changing the direction of folding at some folds. We discuss the variety of tubular structures that can be conceived and we show limitations that govern the geometric design. We quantify the global stiffness of the origami tubes through eigenvalue and structural analyses and highlight the mechanical characteristics of these systems. The two-scale nature of this work indicates that, from a local viewpoint, the cross-sections of the polygonal tubes are reconfigurable while, from a global viewpoint, deployable tubes of desired shapes are achieved. This class of tubes has potential applications ranging from pipes and micro-robotics to deployable architecture in buildings. PMID:26997894

  8. The Success of Gay-Straight Alliances in Waterloo Region, Ontario: A Confluence of Political and Social Factors

    Science.gov (United States)

    St. John, Alex; Travers, Robb; Munro, Lauren; Liboro, Renato; Schneider, Margaret; Greig, Carrie L.

    2014-01-01

    This article outlines how gay-straight alliances (GSAs) work to connect youth with community resources, and outlines the political and social context of GSAs in Waterloo Region, Ontario, Canada. Fifteen individuals (youth, teachers, and a lesbian, gay, bisexual, transgender, and queer [LGBTQ] youth service provider) participated in interviews…

  9. Critical Pedagogy Enacted in the Gay-Straight Alliance: New Possibilities for a Third Space in Teacher Development

    Science.gov (United States)

    Mayo, J. B., Jr.

    2013-01-01

    Critical pedagogy, combined with partnerships with adults at school, enabled the Gay-Straight Alliance (GSA) advisor to create the foundation for reflective, activist-oriented learning at one Midwestern high school. Underreported in current literature, the use of critical pedagogy in school clubs and/or organizations has broad implications for…

  10. The selection function of the LAMOST Spectroscopic Survey of the Galactic Anti-centre

    Science.gov (United States)

    Chen, B.-Q.; Liu, X.-W.; Yuan, H.-B.; Xiang, M.-S.; Huang, Y.; Wang, C.; Zhang, H.-W.; Tian, Z.-J.

    2018-05-01

    We present a detailed analysis of the selection function of the LAMOST Spectroscopic Survey of the Galactic Anti-centre (LSS-GAC). LSS-GAC was designed to obtain low-resolution optical spectra for a sample of more than 3 million stars in the Galactic anti-centre. The second release of value-added catalogues of the LSS-GAC (LSS-GAC DR2) contains stellar parameters, including radial velocity, atmospheric parameters, elemental abundances, and absolute magnitudes deduced from 1.8 million spectra of 1.4 million unique stars targeted by the LSS-GAC between 2011 and 2014. For many studies using this data base, such as those investigating the chemodynamical structure of the Milky Way, a detailed understanding of the selection function of the survey is indispensable. In this paper, we describe how the selection function of the LSS-GAC can be evaluated to sufficient detail and provide selection function corrections for all spectroscopic measurements with reliable parameters released in LSS-GAC DR2. The results, to be released as new entries in the LSS-GAC value-added catalogues, can be used to correct the selection effects of the catalogue for scientific studies of various purposes.

  11. Queer eye for the straight guy: sexual orientation and stereotype lift effects on performance in the fashion domain.

    Science.gov (United States)

    Cotner, Chad; Burkley, Melissa

    2013-01-01

    Stereotype lift is defined as a boost in performance caused by an awareness of a positive ingroup stereotype. This study investigated if gay men experience stereotype lift in the fashion domain. To date, no studies have examined stereotype lift in regards to stereotypes about sexual orientation or in regards to a non-academic task. To address this gap in the literature, gay and straight men completed a test of fashion knowledge under conditions where the relevant gay stereotype was either salient or not by reminding participants of their sexual orientation before or after completing the test. A sample of 66 undergraduate male students (31 heterosexual and 35 homosexual) showed that gay men did outperform straight men on the fashion test, but only when the relevant stereotype was made salient, F(1, 62) = 5.23, p = .03. Implications of stereotype lift in gay men and on non-academic tasks are discussed.

  12. Heat transfer to liquid sodium in a straight duct in the presence of a transverse magnetic field and a gravity field

    International Nuclear Information System (INIS)

    Majid, A.

    1998-01-01

    Heat transfer to liquid sodium in the presence of a transverse magnetic field and gravity field was analyzed in a square cross section straight duct. The duct had conducting vanadium walls. Magnetohydrodynamic equations in three dimensions and energy equation in three dimensions in cartesian coordinate system were solved. Firstly Nusselt number was calculated with no magnetic field and gravity field. Secondly the Nusselt number was calculated for the case of transverse magnetic field acting on the fluid. Thirdly Nusselt number was calculated for the case of transverse magnetic field and gravity field acting on the fluid. Only one face of the channel was heated. It was found that Nusselt number is not sensitive to application of gravity field and is slightly sensitive to application of transverse magnetic field. The sensitivity of Nusselt number to magnetic field intensity becomes almost negligible after increasing the strength of magnetic field to 0.1 Tesla. (author)

  13. Kinetics of thermophilic, anaerobic oxidation of straight and branched chain butyrate and valerate

    DEFF Research Database (Denmark)

    Batstone, Damien J.; Pind, Peter Frode; Angelidaki, Irini

    2003-01-01

    The degradation kinetics of normal and branched chain butyrate and valerate are important in protein-fed anaerobic systems, as a number of amino acids degrade to these organic acids. Including activated and primary wastewater sludge digesters, the majority of full-scale systems digest feeds...... is also addressed, extending previous pure-culture and batch studies. A previously published mathematical model was modified to allow competitive uptake of i-valerate, and used to model a thermophilic manure digester operated over 180 days. The digester was periodically pulsed with straight and branched...

  14. Comparison of heat transfer in straight and corrugated minichannels with two-phase flow

    Directory of Open Access Journals (Sweden)

    Peukert P.

    2014-03-01

    Full Text Available Measurements of heat transfer rates performed with an experimental condensation heat exchanger are reported for a corrugated minichannel tube and for a straight minichannel tube. The two cases were compared at same flow regimes. The corrugation appears advantageous for relatively low steam pressures and flow rates where much higher heat transfer rates were observed close to the steam entrance, thus allowing shortening the heat exchanger with the associated advantages of costs lowering and smaller built-up space. At high steam pressures and high flow rates both tubes performed similarly.

  15. Questa baseline and pre-mining ground-water quality investigation. 14. Interpretation of ground-water geochemistry in catchments other than the Straight Creek catchment, Red River Valley, Taos County, New Mexico, 2002-2003

    Science.gov (United States)

    Nordstrom, D. Kirk; McCleskey, R. Blaine; Hunt, Andrew G.; Naus, Cheryl A.

    2005-01-01

    The U.S. Geological Survey, in cooperation with the New Mexico Environment Department, is investigating the pre-mining ground-water chemistry at the Molycorp molybdenum mine in the Red River Valley, New Mexico. The primary approach is to determine the processes controlling ground-water chemistry at an unmined, off-site but proximal analog. The Straight Creek catchment, chosen for this purpose, consists of the same Tertiary-age quartz-sericite-pyrite altered andesite and rhyolitic volcanics as the mine site. Straight Creek is about 5 kilometers east of the eastern boundary of the mine site. Both Straight Creek and the mine site are at approximately the same altitude, face south, and have the same climatic conditions. Thirteen wells in the proximal analog drainage catchment were sampled for ground-water chemistry. Eleven wells were installed for this study and two existing wells at the Advanced Waste-Water Treatment (AWWT) facility were included in this study. Eight wells were sampled outside the Straight Creek catchment: one each in the Hansen, Hottentot, and La Bobita debris fans, four in a well cluster in upper Capulin Canyon (three in alluvial deposits and one in bedrock), and an existing well at the U.S. Forest Service Questa Ranger Station in Red River alluvial deposits. Two surface waters from the Hansen Creek catchment and two from the Hottentot drainage catchment also were sampled for comparison to ground-water compositions. In this report, these samples are evaluated to determine if the geochemical interpretations from the Straight Creek ground-water geochemistry could be extended to other ground waters in the Red River Valley , including the mine site. Total-recoverable major cations and trace metals and dissolved major cations, selected trace metals, anions, alkalinity; and iron-redox species were determined for all surface- and ground-water samples. Rare-earth elements and low-level As, Bi, Mo, Rb, Re, Sb, Se, Te, Th, U, Tl, V, W, Y, and Zr were

  16. Cochlear implantation in Mondini's deformity: could the straight electrode array with length of 31 mm be fully inserted?

    Science.gov (United States)

    Sun, Jia-Qiang; Sun, Jing-Wu; Hou, Xiao-Yan

    2017-07-01

    The straight electrode array with length of 31 mm can be fully inserted using round window insertion in cochlear implantation with Mondini's deformity. It is a safe and effective process, but also a challenging task of the full implantation in children with Mondini's deformity. The aim of this study is to discuss whether the straight electrode array with a length of 31 mm could be fully inserted in cochlear implantation with Mondini's deformity. A chart review of 30 patients undergoing cochlear implantation with Mondini's deformity using the electrode array with length of 31 mm was undertaken from January 2012 and December 2015 in Anhui Provincial Hospital. Full insertion of the straight electrode array with length of 31 mm were performed successfully in all patients with Mondini's deformity using round window insertion. Resistance was not encountered while introducing the electrodes. Ten of 30 patients had cerebrospinal fluid drainage during cochlear implantation. Cerebrospinal fluid drainage was controlled with small pieces of temporalis fascia packing round window in all patients. Intra-operative neural response telemetry was performed in all patients, and results were good. The result of X-ray showed proper placement of the cochlear implant electrode array. During surgery, no patients had experienced any immediate or delayed post-operative complications such as wound infection, intracranial complication, extrusion, or migration of the implant during an average follow-up period of 6-36 months.

  17. Some results of the 50 MW straight tube steam generator test in the TNO 50 MW SCTF at Hengelo

    International Nuclear Information System (INIS)

    Ludwig, P.W.P.H.; Hus, B.M.

    1975-01-01

    A prototype 50 MW straight tube steam generator has been tested during more than 3000 hours under operating conditions. The steady state, transient and stability behaviour were tested. The most remarkable results of the experiments are given. (author)

  18. Some results of the 50 MW straight tube steam generator test in the TNO 50 MW SCTF at Hengelo

    Energy Technology Data Exchange (ETDEWEB)

    Ludwig, P W.P.H.; Hus, B M

    1975-07-01

    A prototype 50 MW straight tube steam generator has been tested during more than 3000 hours under operating conditions. The steady state, transient and stability behaviour were tested. The most remarkable results of the experiments are given. (author)

  19. Comparison of Two Types of Double-J Ureteral Stents that Differ in Diameter and the Existence of Multiple Side Holes along the Straight Portion in Malignant Ureteral Strictures.

    Science.gov (United States)

    Song, Myung Gyu; Seo, Tae-Seok; Lee, Chang Hee; Kim, Kyeong Ah; Kim, Jun Suk; Oh, Sang Cheul; Lee, Jae-Kwan

    2015-06-01

    This study was decided to evaluate the impact of diameter and the existences of multiple side holes along the straight portion of double-J ureteral stents (DJUS) on early dysfunction of stents placed for malignant ureteral strictures. Between April 2007 and December 2011, 141 DJUSs were placed via a percutaneous nephrostomy (PCN) tract in 110 consecutive patients with malignant ureteral strictures. 7F DJUSs with multiple side holes in the straight portion were placed in 58 ureters of 43 patients (Group 1). 8F DJUSs with three side holes in the proximal 2-cm of the straight portion were placed in 83 ureters of 67 patients (Group 2). The incidence of early DJUS dysfunction was compared between the two groups, and nephrostographic findings were evaluated in the cases of early dysfunction. Early dysfunction of the DJUS was noted in 14 of 58 patients (24.1 %) in Group 1, which was significantly higher (p = 0.001) than in Group 2 in which only 1 of 83 patients (1.2 %) had early dysfunction of the DJUS. Nephrostographic findings of early dysfunction included dilatation of the pelvicalyceal system, filling defects in the ureteral stent, and no passage of contrast media into the urinary bladder. In malignant ureteral strictures, multiple side holes in the straight portion of the 7-F DJUS seem to cause early dysfunction. The 8F DJUSs with three side holes in the proximal 2-cm of the straight portion may be superior at preventing early dysfunction.

  20. Fracture studies on stainless steel straight pipes under earthquake-type cyclic loading

    International Nuclear Information System (INIS)

    Raghava, G.; Vishnuvardhan, S.; Gandhi, P.; Vaze, K.K.

    2014-01-01

    In order to study the crack growth and cyclic fracture behaviour, which are required for realistic assessment of Leak Before Break (LBB) applicability, experimental investigations were carried out on straight pipes under quasi-crystal loading. Totally 13 pipes were tested; three were stainless steel welded (SSW) using conventional shielded metal arc welding (SMAW) technique and the remaining specimens were Narrow Gap Welded (NGW). The fracture tests were carried out under load control, displacement control and combination of the two; the pipes were subjected to different amplitudes of load or load-line displacement (LLD), which were decided based on the response of the pipes under monotonic loading. Cyclic tearing and crack growth studies on eight straight pipes of the same material reported earlier in published literature are also considered for studying the results and understanding the behaviour. Under load control, with almost equal load amplitude, the NGW pipe exhibited improved life in comparison with SMAW pipe when both are subjected to cyclic loading. The crack growth and tearing instability behaviour of the pipes were studied. The same were found to be different for load control, displacement control and combined control tests. Based in the load-controlled experimental results, material specific plot between cyclic load amplitude (as a percentage of maximum load carrying capacity of a specimen under monotonic fracture) and number of cycles to failure was obtained. The results indicate that the piping components subjected to quasi-cyclic loading may fail in very less number of cycles even when the load amplitude is sufficiently below the monotonic fracture/collapse load. These studies will be helpful in designing nuclear power plant (NPP) piping components subjected to earthquake-type cyclic loading. (author)

  1. Context-based coding of bilevel images enhanced by digital straight line analysis

    DEFF Research Database (Denmark)

    Aghito, Shankar Manuel; Forchhammer, Søren

    2006-01-01

    , or segmentation maps are also encoded efficiently. The algorithm is not targeted at document images with text, which can be coded efficiently with dictionary-based techniques as in JBIG2. The scheme is based on a local analysis of the digital straightness of the causal part of the object boundary, which is used...... in the context definition for arithmetic encoding. Tested on individual images of standard TV resolution binary shapes and the binary layers of a digital map, the proposed algorithm outperforms PWC, JBIG, JBIG2, and MPEG-4 CAE. On the binary shapes, the code lengths are reduced by 21%, 27 %, 28 %, and 41...

  2. GERDA test facility for pressurized water reactors with straight tube steam generators

    International Nuclear Information System (INIS)

    Ahrens, G.; Haury, G.; Lahner, K.; Schatz, A.

    1983-01-01

    A number of large-scale experimental facilities have been constructed and operate in order to experiment on the thermodynamic and thermohydraulic behaviour of nuclear facilities in case of LOCA. Most of them were designed for ''large leak'' accidents, but as ''small leak'' accidents became the focus of interest, such experiments were also carried out. Experiments carried out with this arrangement for PWR-type reactors with straight-tube steam generators are only partially evaluable. BBR and B and W therefore cooperated in the construction of the test facility GERDA, designed for testing reactors of BBR design. It supplied relevant experimental results for the nuclear power plant at Muelheim-Kaerlich. (orig.) [de

  3. Essential Boundary Conditions with Straight C1 Finite Elements in Curved Domains

    International Nuclear Information System (INIS)

    Ferraro, N.M.; Jardin, S.C.; Luo, X.

    2010-01-01

    The implementation of essential boundary conditions in C1 finite element analysis requires proper treatment of both the boundary conditions on second-order differentials of the solution and the curvature of the domain boundary. A method for the imposition of essential boundary conditions using straight elements (where the elements are not deformed to approximate a curved domain) is described. It is shown that pre-multiplication of the matrix equation by the local rotation matrix at each boundary node is not the optimal transformation. The uniquely optimal transformation is found, which does not take the form of a similarity transformation due to the non-orthogonality of the transformation to curved coordinates.

  4. Biomechanical evaluation of straight antegrade nailing in proximal humeral fractures: the rationale of the "proximal anchoring point".

    Science.gov (United States)

    Euler, Simon A; Petri, Maximilian; Venderley, Melanie B; Dornan, Grant J; Schmoelz, Werner; Turnbull, Travis Lee; Plecko, Michael; Kralinger, Franz S; Millett, Peter J

    2017-09-01

    Varus failure is one of the most common failure modes following surgical treatment of proximal humeral fractures. Straight antegrade nails (SAN) theoretically provide increased stability by anchoring to the densest zone of the proximal humerus (subchondral zone) with the end of the nail. The aim of this study was to biomechanically investigate the characteristics of this "proximal anchoring point" (PAP). We hypothesized that the PAP would improve stability compared to the same construct without the PAP. Straight antegrade humeral nailing was performed in 20 matched pairs of human cadaveric humeri for a simulated unstable two-part fracture. Biomechanical testing, with stepwise increasing cyclic axial loading (50-N increments each 100 cycles) at an angle of 20° abduction revealed significantly higher median loads to failure for SAN constructs with the PAP (median, 450 N; range, 200-1.000 N) compared to those without the PAP (median, 325 N; range, 100-500 N; p = 0.009). SAN constructs with press-fit proximal extensions (endcaps) showed similar median loads to failure (median, 400 N; range, 200-650 N), when compared to the undersized, commercially available SAN endcaps (median, 450 N; range, 200-600 N; p = 0.240). The PAP provided significantly increased stability in SAN constructs compared to the same setup without this additional proximal anchoring point. Varus-displacing forces to the humeral head were superiorly reduced in this setting. This study provides biomechanical evidence for the "proximal anchoring point's" rationale. Straight antegrade humeral nailing may be beneficial for patients undergoing surgical treatment for unstable proximal humeral fractures to decrease secondary varus displacement and thus potentially reduce revision rates.

  5. A comprehensive evaluation of the mechanism of skin tumorigenesis by straight-run and cracked petroleum middle distillates.

    Science.gov (United States)

    Nessel, C S; Priston, R A; McKee, R H; Cruzan, G; Riley, A J; Hagemann, R; Plutnick, R T; Simpson, B J

    1998-07-01

    The role of skin irritation and other factors on the tumorigenic activity of petroleum middle distillates (PMDs) in mice was examined in a comprehensive research program. The program culminated in a 2-year dermal carcinogenicity study which compared the effects of equal weekly doses of irritating and nonirritating PMDs. Modified Ames mutagenicity studies and three- to seven-ring polycyclic aromatic compound (PAC) analyses indicated that the mutagenic activity of PMDs was correlated to PAC content. In subchronic and subacute studies, PMDs produced marked skin irritation which was ameliorated if the test samples were diluted in mineral oil. The reduction in irritation level was not a result of reduced dermal absorption. Straight-run kerosine (SRK), straight-run gas oil (SRGO), and catalytically cracked light cycle oil (LCO) were evaluated in the dermal carcinogenicity study. Test materials were applied either undiluted (2x/week) or as 28.5% (7x/week) or 50% (4x/week) concentrations in mineral oil for a total weekly dose of 100 microliters PMD per animal. All three materials produced moderate to marked skin irritation and increased tumor frequency when applied undiluted. When diluted, the irritant effects of SRK and SRGO, which contain low levels of PACs, were ameliorated, and there were no significant increases in tumors relative to controls. LCO, containing 8.7% three- to seven-ring PACs, increased tumor frequency when diluted, even when skin irritation was limited. These data indicate that the tumorigenic activity of straight-run MDs is likely a consequence of a nongenotoxic process, associated with frequent cell damage and repair. PMDs which contain low levels of three- to seven-ring PACs are unlikely to cause tumors in the absence of prolonged skin irritation. In addition, genotoxic mechanisms may also contribute to tumor formation for other PMDs containing higher levels of PACs, e.g., products blended with cracked stocks.

  6. Assessment of straight, zigzag, S-shape, and airfoil PCHEs for intermediate heat exchangers of HTGRs and SFRs

    Energy Technology Data Exchange (ETDEWEB)

    Seung Hyun, Yoon, E-mail: ysh3662@kaist.ac.kr [Korea Advanced Institute of Science and Technology (KAIST), Department of Nuclear and Quantum Engineering, 291 Daehak-ro, Yuseong-gu, Daejeon 305-701 (Korea, Republic of); Hee Cheon, NO, E-mail: hcno@kaist.ac.kr [Korea Advanced Institute of Science and Technology (KAIST), Department of Nuclear and Quantum Engineering, 291 Daehak-ro, Yuseong-gu, Daejeon 305-701 (Korea, Republic of); Gil Beom, Kang, E-mail: gbkang@kaeri.re.kr [Korea Advanced Institute of Science and Technology (KAIST), Department of Nuclear and Quantum Engineering, 291 Daehak-ro, Yuseong-gu, Daejeon 305-701 (Korea, Republic of); Team of Advanced International Studies, Korea Atomic Energy Research Institute, Yuseong-gu, Daejeon 305-353 (Korea, Republic of)

    2014-04-01

    Highlights: • We propose Fanning factor and Nusselt number correlations for the airfoil PCHE. • We evaluate the thermal–hydraulic performance for each PCHE type in terms of the total cost. • The zigzag PCHE is the most appropriate IHX for the HTGRs, operating in laminar region. • The straight PCHE is the best for the IHX in the SFRs, operating in turbulent region. - Abstract: A promising candidate for the intermediate heat exchanger (IHX) in high temperature gas-cooled reactors (HTGRs) and sodium-cooled fast reactors (SFRs) is a printed circuit heat exchanger (PCHE) due to its high effectiveness and compactness. We developed the thermal–hydraulic correlations for an airfoil PCHE by three-dimensional computational fluid dynamics (3D-CFD) analysis, which are applicable over the range of Reynolds number from 0 to 150,000, including helium in laminar region and CO{sub 2} in turbulent region. Proposed Fanning factor correlation for the entire range showed the normalized root mean square deviation (NRMSD) as 2.52%. NRMSDs for two Nusselt number models for each flow region were calculated as 4.66% and 0.82%. We compared the total cost considering material and operation cost for the IHXs in HTGRs and SFRs with 4 types of PCHEs, which are straight, zigzag, S-shape, and airfoil PCHEs. For the IHXs of pebble bed modular reactor (PBMR) operating in the laminar region, the zigzag PCHE is the best option because of its lowest pressure drop and relatively high heat transfer area. The straight PCHE for the IHXs of Kalimer-600 is definitely the best option due to its much lower pressure drop, which is one reactor type of the SFRs operating in the turbulent region.

  7. Multidirectional Scanning Model, MUSCLE, to Vectorize Raster Images with Straight Lines

    Directory of Open Access Journals (Sweden)

    Ibrahim Baz

    2008-04-01

    Full Text Available This paper presents a new model, MUSCLE (Multidirectional Scanning for Line Extraction, for automatic vectorization of raster images with straight lines. The algorithm of the model implements the line thinning and the simple neighborhood methods to perform vectorization. The model allows users to define specified criteria which are crucial for acquiring the vectorization process. In this model, various raster images can be vectorized such as township plans, maps, architectural drawings, and machine plans. The algorithm of the model was developed by implementing an appropriate computer programming and tested on a basic application. Results, verified by using two well known vectorization programs (WinTopo and Scan2CAD, indicated that the model can successfully vectorize the specified raster data quickly and accurately.

  8. Adaptation of Lean Six Sigma Methodologies for the Evaluation of Veterans Choice Program at 3 Urban Veterans Affairs Medical Centers.

    Science.gov (United States)

    Ball, Sherry L; Stevenson, Lauren D; Ladebue, Amy C; McCreight, Marina S; Lawrence, Emily C; Oestreich, Taryn; Lambert-Kerzner, Anne C

    2017-07-01

    The Veterans Health Administration (VHA) is adapting to meet the changing needs of our Veterans. VHA leaders are promoting quality improvement strategies including Lean Six Sigma (LSS). This study used LSS tools to evaluate the Veterans Choice Program (VCP), a program that aims to improve access to health care services for eligible Veterans by expanding health care options to non-VHA providers. LSS was utilized to assess the current process and efficiency patterns of the VCP at 3 VHA Medical Centers. LSS techniques were used to assess data obtained through semistructured interviews with Veterans, staff, and providers to describe and evaluate the VCP process by identifying wastes and defects. The LSS methodology facilitated the process of targeting priorities for improvement and constructing suggestions to close identified gaps and inefficiencies. Identified key process wastes included inefficient exchange of clinical information between stakeholders in and outside of the VHA; poor dissemination of VCP programmatic information; shortages of VCP-participating providers; duplication of appointments; declines in care coordination; and lack of program adaptability to local processes. Recommendations for improvement were formulated using LSS. This evaluation illustrates how LSS can be utilized to assess a nationally mandated health care program. By focusing on stakeholder, staff, and Veteran perspectives, process defects in the VCP were identified and improvement recommendations were made. However, the current LSS language used is not intuitive in health care and similar applications of LSS may consider using new language and goals adapted specifically for health care.

  9. Growth, straightness and survival at age 32 in a Pinus strobus x P. wallichiana F1 hybrid population (Experiment 1

    Directory of Open Access Journals (Sweden)

    Ioan Blada

    2013-12-01

    Full Text Available An interspecific factorial hybridization was made, where seven P. strobus female parent trees were mated to four P. wallichiana male trees, in order to transfer genes for resistance to blister-rust from the blue pine to the F1 hybrids. The hybrid seedlings and the open pollinated families of the two parents were three times consecutively inoculated with blister-rust. The six years old seedlings were transplanted in the fi eld in the so called Valiug Experiment 1. The experimental design consisted in 28 hybrid full-sib families and two open pollinated families of the parent species. Plantation took place in a complete randomized block design with three blocks, with 6 to 12 seedlings per linear plot and 3 x 3 m spacing. This paper is based on the measurements made at age 32, just after the fi rst thinning. Diameter at breast height, tree height, tree volume, stem straightness and tree survival were the fi ve measured traits. According to ANOVA, signifi cant (p < 0.05 and highly signifi cant (p < 0.001 differences for diameter at breast height, tree height, volume growth rate, stem straightness and tree survival were detected between hybrid families. Highly signifi cant (p< 0.01, p < 0.001 differences were found between eastern white pine female parents for survival, stem straightness and all growth traits, suggesting that nuclear additive genes are controlling the respective characters. Consequently, high survival or genetic resistance to blister-rust can be found within the P. strobus species even though it is highly susceptible to this pathogen. The P. wallichiana parents exhibited signifi cant additive effects on straightness and breast height diameter, but no signifi cance in height, volume, and tree survival. The contribution of the additive variance to the phenotypic one was 65.7% for diameter, 58.6% for height, 50.5% for volume, 70.4% for stem straightness and 73.4% for tree survival. Hence, additive variance should be employed

  10. New Upgrade Project for the Photon Factory Storage Ring

    International Nuclear Information System (INIS)

    Asaoka, S.; Haga, K.; Harada, K.; Honda, T.; Hori, Y.; Izawa, M.; Kasuga, T.; Kobayashi, M.; Kobayashi, Y.; Maezawa, H.; Minagawa, Y.; Mishina, A.; Mitsuhashi, T.; Miyajima, T.; Miyauchi, H.; Nagahashi, S.; Nogami, T.; Obina, T.; Pak, C. O.; Sakanaka, S.

    2004-01-01

    A new project for upgrading the 2.5-GeV Photon Factory (PF) storage ring is now being undertaken to create six new short-straight sections and to lengthen the existing eight straight sections. The short-straight sections will provide an opportunity to install short-period narrow-gap undulators, while the extensions of existing straight sections will be taken advantage of updating current insertion devices to the latest models in future. To this end, the lattice configuration around the straight sections is modified by replacing old quadrupole magnets with new shorter ones and placing them closer to the near-by bending magnets. Necessary replacement of the vacuum ducts and the beamline front ends will be carried out together. This project will be completed by the end of September, 2005, after six months of shutdown

  11. Autoignition of straight-run naphtha: A promising fuel for advanced compression ignition engines

    KAUST Repository

    Alabbad, Mohammed; Issayev, Gani; Badra, Jihad; Voice, Alexander K.; Giri, Binod; Djebbi, Khalil; Ahmed, Ahfaz; Sarathy, Mani; Farooq, Aamir

    2017-01-01

    Naphtha, a low-octane distillate fuel, has been proposed as a promising low-cost fuel for advanced compression ignition engine technologies. Experimental and modelling studies have been conducted in this work to assess autoignition characteristics of naphtha for use in advanced engines. Ignition delay times of a certified straight-run naphtha fuel, supplied by Haltermann Solutions, were measured in a shock tube and a rapid comparison machine over wide ranges of experimental conditions (20 and 60 bar, 620–1223 K, ϕ = 0.5, 1 and 2). The Haltermann straight-run naphtha (HSRN) has research octane number (RON) of 60 and motor octane number (MON) of 58.3, with carbon range spanning C3–C9. Reactivity of HSRN was compared, via experiments and simulations, with three suitably formulated surrogates: a two-component PRF (n-heptane/iso-octane) surrogate, a three-component TPRF (toluene/n-heptane/iso-octane) surrogate, and a six-component surrogate. All surrogates reasonably captured the ignition delays of HSRN at high and intermediate temperatures. However, at low temperatures (T < 750 K), the six-component surrogate performed the best in emulating the reactivity of naphtha fuel. Temperature sensitivity and rate of production analyses revealed that the presence of cyclo-alkanes in naphtha inhibits the overall fuel reactivity. Zero-dimensional engine simulations showed that PRF is a good autoignition surrogate for naphtha at high engine loads, however, the six-component surrogate is needed to match the combustion phasing of naphtha at low engine loads.

  12. Autoignition of straight-run naphtha: A promising fuel for advanced compression ignition engines

    KAUST Repository

    Alabbad, Mohammed

    2017-11-24

    Naphtha, a low-octane distillate fuel, has been proposed as a promising low-cost fuel for advanced compression ignition engine technologies. Experimental and modelling studies have been conducted in this work to assess autoignition characteristics of naphtha for use in advanced engines. Ignition delay times of a certified straight-run naphtha fuel, supplied by Haltermann Solutions, were measured in a shock tube and a rapid comparison machine over wide ranges of experimental conditions (20 and 60 bar, 620–1223 K, ϕ = 0.5, 1 and 2). The Haltermann straight-run naphtha (HSRN) has research octane number (RON) of 60 and motor octane number (MON) of 58.3, with carbon range spanning C3–C9. Reactivity of HSRN was compared, via experiments and simulations, with three suitably formulated surrogates: a two-component PRF (n-heptane/iso-octane) surrogate, a three-component TPRF (toluene/n-heptane/iso-octane) surrogate, and a six-component surrogate. All surrogates reasonably captured the ignition delays of HSRN at high and intermediate temperatures. However, at low temperatures (T < 750 K), the six-component surrogate performed the best in emulating the reactivity of naphtha fuel. Temperature sensitivity and rate of production analyses revealed that the presence of cyclo-alkanes in naphtha inhibits the overall fuel reactivity. Zero-dimensional engine simulations showed that PRF is a good autoignition surrogate for naphtha at high engine loads, however, the six-component surrogate is needed to match the combustion phasing of naphtha at low engine loads.

  13. First Metatarsal Proximal Opening Wedge Osteotomy for Correction of Hallux Valgus Deformity: Comparison of Straight versus Oblique Osteotomy

    Science.gov (United States)

    Han, Seung Hwan; Park, Eui Hyun; Jo, Joon; Koh, Yong Gon; Lee, Jin Woo; Choi, Woo Jin

    2015-01-01

    Purpose The aim of this study was to compare clinical and radiographic outcomes of proximal opening wedge osteotomy using a straight versus oblique osteotomy. Materials and Methods We retrospectively reviewed 104 consecutive first metatarsal proximal opening wedge osteotomies performed in 95 patients with hallux valgus deformity. Twenty-six feet were treated using straight metatarsal osteotomy (group A), whereas 78 feet were treated using oblique metatarsal osteotomy (group B). The hallux valgus angle (HVA), intermetatarsal angle (IMA), distal metatarsal articular angle, and distance from the first to the second metatarsal (distance) were measured for radiographic evaluation, whereas the American Orthopaedic Foot and Ankle Society (AOFAS) forefoot score was used for clinical evaluation. Results Significant corrections in the HVA, IMA, and distance from the first to the second metatarsal were obtained in both groups at the last follow-up (p<0.001). There was no difference in the mean IMA correction between the 2 groups (6.1±2.7° in group A and 6.0±2.1° in group B). However, a greater correction in the HVA and distance from the first to the second metatarsal were found in group B (HVA, 13.2±8.2°; distance, 25.1±0.2 mm) compared to group A (HVA, 20.9±7.7°; distance, 28.1±0.3 mm; p<0.001). AOFAS scores were improved in both groups. However, group B demonstrated a greater improvement relative to group A (p=0.005). Conclusion Compared with a straight first metatarsal osteotomy, an oblique first metatarsal osteotomy yielded better clinical and radiological outcomes. PMID:25837181

  14. Influence of artificial aging on the load-bearing capability of straight or angulated zirconia abutments in implant/tooth-supported fixed partial dentures.

    Science.gov (United States)

    Nothdurft, Frank P; Doppler, Klaus E; Erdelt, Kurt J; Knauber, Andreas W; Pospiech, Peter R

    2010-01-01

    The aim of the study was to evaluate the influence of artificial aging on the fracture behavior of straight and angulated zirconia implant abutments used in ZirDesign (Astra Tech) implant/tooth-supported fixed partial dentures (FPDs) in the maxilla. Four different test groups (n = 8) representing anterior implant/tooth-supported FPDs were prepared. Groups 1 and 2 simulated a clinical situation with an ideal implant position (maxillary left central incisor) from a prosthetic point of view, which allowed for the use of a straight, prefabricated zirconia abutment. Groups 3 and 4 simulated a situation with a compromised implant position that required an angulated (20-degree) abutment. OsseoSpeed implants (4.5 3 13 mm, Astra Tech) as well as metal tooth analogs (maxillary right lateral incisor) with simulated periodontal mobility were mounted in polymethyl methacrylate. The FPDs (chromium-cobalt alloy) were cemented with glass ionomer. Groups 2 and 4 were thermomechanically loaded and subjected to static loading until failure. Statistical analysis of force data at the fracture site was performed using nonparametric tests. All samples survived thermomechanical loading. Artificial aging did not lead to a significant decrease in load-bearing capacity in either the straight abutments or the angulated abutments. The restorations that used angulated abutments exhibited higher fracture loads than the restorations with straight abutments (group 1: 209.13 ± 39.11 N; group 2: 233.63 ± 30.68 N; group 3: 324.62 ± 108.07 N; group 4: 361.75 ± 73.82 N). This difference in load-bearing performance was statistically significant, both with and without artificial aging. All abutment fractures occurred below the implant shoulder. Compensation for angulated implant positions with an angulated zirconia abutment is possible without reducing the load-bearing capacity of implant/tooth-supported anterior FPDs.

  15. Comparison of Two Types of Double-J Ureteral Stents that Differ in Diameter and the Existence of Multiple Side Holes along the Straight Portion in Malignant Ureteral Strictures

    Energy Technology Data Exchange (ETDEWEB)

    Song, Myung Gyu, E-mail: acube808@naver.com; Seo, Tae-Seok, E-mail: g1q1papa@korea.ac.kr; Lee, Chang Hee, E-mail: chlee86@korea.ac.kr; Kim, Kyeong Ah, E-mail: kahkim@korea.ac.kr [Korea University College of Medicine, Department of Radiology, Korea University Guro Hospital (Korea, Republic of); Kim, Jun Suk, E-mail: kjs6651@kumc.or.kr; Oh, Sang Cheul, E-mail: sachoh@korea.ac.kr [Korea University College of Medicine, Department of Oncology, Korea University Guro Hospital (Korea, Republic of); Lee, Jae-Kwan, E-mail: jklee38@korea.ac.kr [Korea University College of Medicine, Department of Gynecology, Korea University Guro Hospital (Korea, Republic of)

    2015-06-15

    PurposeThis study was decided to evaluate the impact of diameter and the existences of multiple side holes along the straight portion of double-J ureteral stents (DJUS) on early dysfunction of stents placed for malignant ureteral strictures.MethodsBetween April 2007 and December 2011, 141 DJUSs were placed via a percutaneous nephrostomy (PCN) tract in 110 consecutive patients with malignant ureteral strictures. 7F DJUSs with multiple side holes in the straight portion were placed in 58 ureters of 43 patients (Group 1). 8F DJUSs with three side holes in the proximal 2-cm of the straight portion were placed in 83 ureters of 67 patients (Group 2). The incidence of early DJUS dysfunction was compared between the two groups, and nephrostographic findings were evaluated in the cases of early dysfunction.ResultsEarly dysfunction of the DJUS was noted in 14 of 58 patients (24.1 %) in Group 1, which was significantly higher (p = 0.001) than in Group 2 in which only 1 of 83 patients (1.2 %) had early dysfunction of the DJUS. Nephrostographic findings of early dysfunction included dilatation of the pelvicalyceal system, filling defects in the ureteral stent, and no passage of contrast media into the urinary bladder.ConclusionsIn malignant ureteral strictures, multiple side holes in the straight portion of the 7-F DJUS seem to cause early dysfunction. The 8F DJUSs with three side holes in the proximal 2-cm of the straight portion may be superior at preventing early dysfunction.

  16. Straight and branched-chain fatty acids in preorbital glands of sika deer, Cervus nippon.

    Science.gov (United States)

    Wood, William F

    2004-02-01

    Using GC-MS analysis, 11 major volatile compounds were found in the preorbital gland secretion from a female sika deer, Cervus nippon. These compounds are the C14 through C18 straight-chain fatty acids, (ZZ)-9,12-octadecadienoic acid, 12-methyltridecanoic acid, 13-methyltetradecanoic acid, 14-methylpentadecanoic acid, 14-methylhexadecanoic acid, and 15-methylhexadecanoic acid. The five branched-chain acids make up over 29% of the volatiles in the gland. This is the first time branched-chain carboxylic acids have been reported from ungulate preorbital glands.

  17. The feedback control research on straight and curved road with car-following model

    Science.gov (United States)

    Zheng, Yi-Ming; Cheng, Rong-Jun; Ge, Hong-Xia

    2017-07-01

    Taking account of the road consisting of curved part and straight part, an extended car-following model is proposed in this paper. A control signal including the velocity difference between the considered vehicle and the vehicle in front is taken into account. The control theory method is applied into analysis of the stability condition for the model. Numerical simulations are implemented to prove that the stability of the traffic flow strengthens effectively with an increase of the radius of curved road, and the control signal can suppress the traffic congestion. The results are in good agree with the theoretical analysis.

  18. Generic Lean Six Sigma project definitions in financial services

    NARCIS (Netherlands)

    de Koning, H.; de Mast, J.; Does, R.J.M.M.; Vermaat, T.; Simons, S.

    2008-01-01

    Lean Six Sigma (LSS) is applied in financial service organizations to improve operational efficiency and effectiveness. LSS prescribes that these improvements are designed and implemented by projects. The purpose of this article is to facilitate the process of defining LSS projects in finance,

  19. Closed Environment Module - Modularization and extension of the Virtual Habitat

    Science.gov (United States)

    Plötner, Peter; Czupalla, Markus; Zhukov, Anton

    2013-12-01

    The Virtual Habitat (V-HAB), is a Life Support System (LSS) simulation, created to perform dynamic simulation of LSS's for future human spaceflight missions. It allows the testing of LSS robustness by means of computer simulations, e.g. of worst case scenarios.

  20. CFD modelling of axial mixing in the intermediate and final rinses of cleaning-in-place procedures of straight pipes

    DEFF Research Database (Denmark)

    Yang, Jifeng; Jensen, Bo Boye Busk; Nordkvist, Mikkel

    2018-01-01

    The intermediate and final rinses of straight pipes, in which water replaces a cleaning agent of similar density and viscosity, are modelled using Computational Fluid Dynamic (CFD) methods. It is anticipated that the displacement process is achieved by convective and diffusive transport. The simu...

  1. A heat transfer study for vertical straight-tube steam generators heated by liquid metal

    International Nuclear Information System (INIS)

    Valette, M.

    1984-04-01

    A single-tube mockup of a vertical straight-tube steam generator heated by sodium-potassium alloy NaK was submitted to thermal and hydraulic testing in conditions representative of fast breeder reactor operation. The mockup consisted of a 10mm I.D. ferritic steel heat exchange tube centered inside a cylindrical stainless steel shell. The complete assembly was 20.9 meters long. Water flowed upward inside the exchange tube, and NaK flowed downward in the annular gap between the tube and the shell. The steam outlet pressure ranged from 90 to 195 bars, while the liquid metal temperature at the mockup inlet was between 480 and 580 0 C. The water flowrate in the tube ranged from 153 to 2460 kg.m -2 .s -1 . During the tests the fluid inlet and outlet temperatures, flowrate and pressures were measured, as was the NaK temperature profile over the full length of the device. The test results were subsequently compared with heat exchange and pressure drop values calculated using the standard formulas for straight-tube heat exchangers. The heat exchange coefficients predicted by these correlations in the boiling zone were found to be largely overestimated, while the calculated pressure drop values proved satisfactory. A set of modified correlations is proposed to account for the observed phenomena, and for use in designing commercial units, provided the sodium flow in the tube bundle is adequately distributed

  2. MHD equilibria in a straight system with a non-planar magnetic axis

    International Nuclear Information System (INIS)

    Harafuji, Kenji; Tsunematsu, Toshihide; Azumi, Masafumi; Takeda, Tatsuoki

    1984-03-01

    Numerical investigations of equilibria with free boundary are made in the straight syste m with a three dimensional magnetic axis. Grad-Shafranov equation is solved by both iterative SOR method and direct method on the basis of LU matrix decomposition. From the standpoint of CPU time, SOR method is better than direct method, when number of outer iterations is executed. A part of the ''Self-Stabilization Effect'' due to the increase of plasma pressure is successfully simulated. On the parameter space where the relation between the rotational transform due to the plasma current and that due to the torsion of helical magnetic axis is subtractive, the convergence region is very small. (author)

  3. Active Brownian particles near straight or curved walls: Pressure and boundary layers

    Science.gov (United States)

    Duzgun, Ayhan; Selinger, Jonathan V.

    2018-03-01

    Unlike equilibrium systems, active matter is not governed by the conventional laws of thermodynamics. Through a series of analytic calculations and Langevin dynamics simulations, we explore how systems cross over from equilibrium to active behavior as the activity is increased. In particular, we calculate the profiles of density and orientational order near straight or circular walls and show the characteristic width of the boundary layers. We find a simple relationship between the enhancements of density and pressure near a wall. Based on these results, we determine how the pressure depends on wall curvature and hence make approximate analytic predictions for the motion of curved tracers, as well as the rectification of active particles around small openings in confined geometries.

  4. Queerspawn Speak out: A Review of "Let's Get This Straight: The Ultimate Handbook for Youth with LGBTQ Parents"

    Science.gov (United States)

    Ryan, Caitlin L.

    2012-01-01

    "Let's Get This Straight: The Ultimate Handbook for Youth With LGBTQ Parents" provides an engaging and accessible set of tools for youth from LGBTQ-headed families. The stories and resources shared encourage these youth to take pride in their families, value their diverse experiences, and work against homophobia, transphobia, and other forms of…

  5. The build up of the correlation between halo spin and the large-scale structure

    Science.gov (United States)

    Wang, Peng; Kang, Xi

    2018-01-01

    Both simulations and observations have confirmed that the spin of haloes/galaxies is correlated with the large-scale structure (LSS) with a mass dependence such that the spin of low-mass haloes/galaxies tend to be parallel with the LSS, while that of massive haloes/galaxies tend to be perpendicular with the LSS. It is still unclear how this mass dependence is built up over time. We use N-body simulations to trace the evolution of the halo spin-LSS correlation and find that at early times the spin of all halo progenitors is parallel with the LSS. As time goes on, mass collapsing around massive halo is more isotropic, especially the recent mass accretion along the slowest collapsing direction is significant and it brings the halo spin to be perpendicular with the LSS. Adopting the fractional anisotropy (FA) parameter to describe the degree of anisotropy of the large-scale environment, we find that the spin-LSS correlation is a strong function of the environment such that a higher FA (more anisotropic environment) leads to an aligned signal, and a lower anisotropy leads to a misaligned signal. In general, our results show that the spin-LSS correlation is a combined consequence of mass flow and halo growth within the cosmic web. Our predicted environmental dependence between spin and large-scale structure can be further tested using galaxy surveys.

  6. Fitting straight lines and planes with an application to radiometric dating

    International Nuclear Information System (INIS)

    Kent, J.T.; Watson, G.S.; Onstott, T.C.

    1990-01-01

    Conventional practice in geochronology is to fit a straight line or ''isochron'' to data consisting of two isotopic ratios by a method that takes into account that fact that both ratios are measured with error. In this paper we use matrix algebra to lay out a general method for fitting linear relations between any number of variables, all subject to errors with known variances and covariances and the well-known Newton-Raphson method to do the optimization. This leads to a good computational algorithm which may also be used e.g. to check whether coefficients in several linear relations are the same. In many fields of science one needs to fit linear relations so our method is of wide utility; its use is in no way restricted to radiometric data. (orig.)

  7. Automated Cross-Sectional Measurement Method of Intracranial Dural Venous Sinuses.

    Science.gov (United States)

    Lublinsky, S; Friedman, A; Kesler, A; Zur, D; Anconina, R; Shelef, I

    2016-03-01

    MRV is an important blood vessel imaging and diagnostic tool for the evaluation of stenosis, occlusions, or aneurysms. However, an accurate image-processing tool for vessel comparison is unavailable. The purpose of this study was to develop and test an automated technique for vessel cross-sectional analysis. An algorithm for vessel cross-sectional analysis was developed that included 7 main steps: 1) image registration, 2) masking, 3) segmentation, 4) skeletonization, 5) cross-sectional planes, 6) clustering, and 7) cross-sectional analysis. Phantom models were used to validate the technique. The method was also tested on a control subject and a patient with idiopathic intracranial hypertension (4 large sinuses tested: right and left transverse sinuses, superior sagittal sinus, and straight sinus). The cross-sectional area and shape measurements were evaluated before and after lumbar puncture in patients with idiopathic intracranial hypertension. The vessel-analysis algorithm had a high degree of stability with <3% of cross-sections manually corrected. All investigated principal cranial blood sinuses had a significant cross-sectional area increase after lumbar puncture (P ≤ .05). The average triangularity of the transverse sinuses was increased, and the mean circularity of the sinuses was decreased by 6% ± 12% after lumbar puncture. Comparison of phantom and real data showed that all computed errors were <1 voxel unit, which confirmed that the method provided a very accurate solution. In this article, we present a novel automated imaging method for cross-sectional vessels analysis. The method can provide an efficient quantitative detection of abnormalities in the dural sinuses. © 2016 by American Journal of Neuroradiology.

  8. Time-varying impedance of the human ankle in the sagittal and frontal planes during straight walk and turning steps.

    Science.gov (United States)

    Ficanha, Evandro M; Ribeiro, Guilherme A; Knop, Lauren; Rastgaar, Mo

    2017-07-01

    This paper describes the methods and experiment protocols for estimation of the human ankle impedance during turning and straight line walking. The ankle impedance of two human subjects during the stance phase of walking in both dorsiflexion plantarflexion (DP) and inversion eversion (IE) were estimated. The impedance was estimated about 8 axes of rotations of the human ankle combining different amounts of DP and IE rotations, and differentiating among positive and negative rotations at 5 instants of the stance length (SL). Specifically, the impedance was estimated at 10%, 30%, 50%, 70% and 90% of the SL. The ankle impedance showed great variability across time, and across the axes of rotation, with consistent larger stiffness and damping in DP than IE. When comparing straight walking and turning, the main differences were in damping at 50%, 70%, and 90% of the SL with an increase in damping at all axes of rotation during turning.

  9. Perceptions of Lean Six Sigma: a multiple case study in the financial services industry

    NARCIS (Netherlands)

    Lameijer, B.A.; Veen, D.T.J.; Does, R.J.M.M.; de Mast, J.

    2016-01-01

    From 2001 onward, books and papers about the application of Lean Six Sigma (LSS) in service industries describe typical LSS deployment characteristics, such as the human element. The objective of this paper is to identify which LSS attributes affect employee and management attitudes and how the

  10. Microduplications encompassing the Sonic Hedgehog Limb Enhancer ZRS are Associated with Haas Type Polysyndactyly and Laurin-Sandrow Syndrome

    DEFF Research Database (Denmark)

    Lohan, Silke; Spielmann, Malte; Doelken, Sandra C

    2014-01-01

    Laurin-Sandrow syndrome (LSS) is a rare autosomal dominant disorder characterized by polysyndactyly of hands and/or feet, mirror image duplication of the feet, nasal defects, and loss of identity between fibula and tibia. The genetic basis of LSS is currently unknown. LSS shows phenotypic overlap...

  11. Field quality of the end sections of SSC [Superconducting Super Collider] dipoles

    International Nuclear Information System (INIS)

    Hassenzahl, W.V.; Caspi, S.; Gilbert, W.; Helm, M.; Laslett, L.J.; Morgan, G.A.

    1986-09-01

    The central or two-dimensional field of a dipole magnet can be calculated with some precision. The fields at the end of the magnet, which are three-dimensional in nature, provide a more complicated problem. Starting with an end design that produced a relatively good end in terms of multipole components, a method of extending parts of the straight section was used to reduce the most important harmonics, the sextupole and decapole, to a negligible level. In addition, the effect of extending an iron yoke over the ends of a magnet was investigated and it was found to have little effect on the harmonics, though it will raise the dipole field. These results are encouraging as they imply that good ends can be developed with relative ease should the two dimensional cross-section of a dipole magnet such as the SSC have to be changed

  12. Decentralized control and filtering in interconnected dynamical systems

    CERN Document Server

    Mahmoud, Magdi S

    2011-01-01

    Based on the many approaches available for dealing with large-scale systems (LSS), Decentralized Control and Filtering in Interconnected Dynamical Systems supplies a rigorous framework for studying the analysis, stability, and control problems of LSS. Providing an overall assessment of LSS theories, it addresses model order reduction, parametric uncertainties, time delays, and control estimator gain perturbations. Taking readers on a guided tour through LSS, the book examines recent trends and approaches and reviews past methods and results from a contemporary perspective. It traces the progre

  13. Facile Synthesis of Long, Straight and Uniform Copper Nanowires via a Solvothermal Method

    Institute of Scientific and Technical Information of China (English)

    Chunfu Lin; Hong Lin; Ning Wang; Xing Zhang; Jun Yang; Jianbo Li; Xiaozhan Yang

    2006-01-01

    Copper nanowires were facilely prepared via a solvothermal method. In this method, cetyltrimethylammonium bromide (CTAB) was used as a soft template, copper nitrate was an inorganic precursor, and absolute ethanol served as a reducing agent as well as a solvent. X-ray diffraction (XRD) and scanning electron microscopy (SEM) were used to characterize the as-prepared copper nanowires. The as-prepared copper nanowires are fairly uniform and long. The majority of them are longer than 100 μm and some even longer than 200 μm. Furthermore, most nanowires are quite straight. In addition,The mechanism of the growth process of copper nanowires was discussed.

  14. Lipase-catalyzed esterification of lactic acid with straight-chain alcohols

    DEFF Research Database (Denmark)

    Rønne, Torben Harald; Xu, Xuebing; Tan, Tianwei

    2005-01-01

    Enzymatic synthesis of esters of lactic acid and straight-chain alcohols with different chain lengths (C6–C18) were investigated in batch reactions with hexadecanol (C16) as the model alcohol. Cyclohexane was the best solvent for higher ester yields, and the best biocatalyst was the immobilized...... Candida antarctica lipase B (Novozym 435) as well as the textile-immobilized Candida sp. lipase. A method was established to obtain ester yields in the range of 71 to 82% for the different alcohols, and the most favorable conditions for the esterification reaction using Novozym 435 were an equimolar ratio...... of lactic acid to alcohol, each at a concentration of 120 mM each; a 50°C reaction temperature; 190 rpm shaking speed; and the addition of 100 mg molecular sieves (4 Å) for drying. The ester yield increased with increasing lipase load, and a yield of 79.2% could be obtained after 24 h of reaction at 20 wt...

  15. Experimental and theoretical investigations on safety of the SNR - straight-tube design steam generator with sodium-water reactions

    International Nuclear Information System (INIS)

    Dumm, K.; Sauermann, F.; Schnitker, W.; Welter, A.

    A number of large sodium-water reaction tests has been performed in a steam generator model in order to verify the layout criteria of the SNR straight-tube design steam generators under accident conditions. The experimental setup is described. The test results and their applicability to the SNR steam generators are given and discussed. (U.S.)

  16. Insertion of a straight peritoneal catheter in an arcuate subcutaneous tunnel by a tunneler: long-term experience.

    Science.gov (United States)

    Favazza, A; Petri, R; Montanaro, D; Boscutti, G; Bresadola, F; Mioni, G

    1995-01-01

    This study describes the results of the insertion of a straight Tenckhoff peritoneal catheter (PC) in an arcuate, caudally concave tunnel using a tunneler designed by the authors. It has a semicircular shape and a bending radius of 4.5 cm. A hospital renal unit. From June 1988 to February 1994, 112 straight Tenckhoff PCs, 62 with one deep cuff (single-cuff PC) and 50 with two cuffs (double-cuff PC), were inserted as first catheters in 112 patients (mean age 62 +/- 13 years), who underwent continuous ambulatory peritoneal dialysis (CAPD). The follow-up was 1099 months (mean 18 +/- 13 months) for single-cuff PCs and 1264 months (mean 25 +/- 15 months) for double-cuff PCs, respectively. After intraperitoneal placement of the PCs by median laparotomy, a 180 degrees arc bend tunnel, with both external and peritoneal exits directed downwards, was created by means of the tunneler. The rate of exit-site infection (ESI) was 0.27 episodes/year (epis/year). The probability of remaining ESI-free was 76%, 60%, and 55% at 1, 2, and 3 years. The rate of tunnel infection (TI) was 0.046 epis/year. The incidence of the double-cuff PC-related ESI and TI tended to be lower than the incidence observed with the single-cuff PC. Episodes of peritonitis were 60 (0.30 epis/year), where 6 were subsequent to ESI and/or TI. Two PCs were lost due to ESI, 3 due to TI, and 11 due to peritonitis. Drainage failure, due to displacement of the PC caused by straightening, involved 3 PCs; 2 were lost. PC survival was 92%, 82%, and 74% at 1, 2 and 3 years, respectively. By an easily used semicircular tunneler, the standard straight Tenckhoff PC can be stably positioned in an arcuate tunnel with both inner and outer exits directed downwards. This tunnel shape, as already suggested by some authors, appears to be an effective technical solution to reducing the PC-related complication rates.

  17. Composição química e resistência mecânica da base de braquetes "Straight-Wire" Superficial hardness and the metallographic characteristics of straight-wire base brackets

    Directory of Open Access Journals (Sweden)

    Luciana de Paula Gontijo

    2004-08-01

    Full Text Available Esse trabalho objetivou comparar as durezas superficiais e as características metalográficas das bases de braquetes "straight-wire" de quatro marcas comerciais: Morelli, Abzil Lancer, Unitek e A-Company. As durezas superficiais foram avaliadas por meio de um teste de dureza realizado com o auxílio de um microdurômetro. Os resultados indicaram diferenças entre as marcas comerciais testadas onde os braquetes da A-Company apresentaram os valores mais altos de dureza (314 HV, seguidos da Unitek (325 HV, Abzil (230 HV e Morelli (192 HV. As características metalográficas das bases de braquetes foram avaliadas por meio de um espectrômetro, onde observou-se a presença de elementos de liga como o cromo, o níquel, o silício, o cobre, o alumínio, o enxofre e o nióbio. A quantidade de cada elemento de liga variou entre as marcas, provavelmente devido ao processo de fabricação industrial, mas sem interferir na qualidade final da liga.The objective of this study was to compare the superficial hardness and the metallographic characteristics of the bases of straight-wire brackets. Brackets from four different manufactures were utilized: Morelli, Abzil Lancer, Unitek and A-Company. The superficial hardness test revealed that the A-Company bracket base had the highest value (314 HV followed by Unitek (325 HV, Abzil (230 HV and Morelli (192 HV. The presence of variable amounts of chrome, nickel, silicon, copper, aluminum, sulfur and niobium was detected by the spectrometer. The quantity of each element varied according to the brand tested and did not interfere with the quality of the alloy. This variance was most likely due to differences in the process of the fabrication of each manufactures.

  18. Combination of straight and tilted implants for supporting screw-retained dental prostheses in atrophic posterior maxillae: A 2-year prospective study.

    Science.gov (United States)

    Casar-Espinosa, Juan-Carlos; Castillo-Oyagüe, Raquel; Serrera-Figallo, María Ángeles; Garrido-Serrano, Roberto; Lynch, Christopher D; Menéndez-Collar, Manuel; Torres-Lagares, Daniel; Gutiérrez-Pérez, José-Luis

    2017-08-01

    To evaluate the two-year survival rate (SR) and marginal bone loss (MBL) of fixed dental prostheses (FDPs) supported by straight (S) and tilted (T) implants under the influence of diverse study variables. A prospective investigation comprising 21 patients provided with a total of 27 maxillary screw-retained restorations fixed to 70 dental implants was developed. Two groups of implants were considered depending on their inclination with respect to the occlusal plane: Group 1 (S, n=37): straight/axial implants and Group 2 (T, n=33): tilted/angled fixations. Each FDP was supported by a combination of S and T implants. SR and MBL were assessed at the time of loading and two years after surgery. Patient-, surgical- and/or rehabilitation-related information was gathered. Data were statistically analysed at the α=0.05 significance level. After 24 months, a 100% SR was achieved and the MBL of S and T implants were statistically similar. T implants located in the molar region showed lower MBL than did those replacing premolars (p=0.031). Upright and angled fixations inserted at posterior maxillary areas resulted in comparable survival rates and peri-implant MBL after two years. The marginal bone resorption around tilted implants depended on their location. Screw-retained restorations fixed to straight and tilted implants seem to be a safe treatment option in posterior atrophic maxillae. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Free vibration analysis of straight-line beam regarded as distributed system by combining Wittrick-Williams algorithm and transfer dynamic stiffness coefficient method

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Myung Soo; Yang, Kyong Uk [Chonnam National University, Yeosu (Korea, Republic of); Kondou, Takahiro [Kyushu University, Fukuoka (Japan); Bonkobara, Yasuhiro [University of Miyazaki, Miyazaki (Japan)

    2016-03-15

    We developed a method for analyzing the free vibration of a structure regarded as a distributed system, by combining the Wittrick-Williams algorithm and the transfer dynamic stiffness coefficient method. A computational algorithm was formulated for analyzing the free vibration of a straight-line beam regarded as a distributed system, to explain the concept of the developed method. To verify the effectiveness of the developed method, the natural frequencies of straight-line beams were computed using the finite element method, transfer matrix method, transfer dynamic stiffness coefficient method, the exact solution, and the developed method. By comparing the computational results of the developed method with those of the other methods, we confirmed that the developed method exhibited superior performance over the other methods in terms of computational accuracy, cost and user convenience.

  20. Optimization of Root Section for Ultra-long Steam Turbine Rotor Blade

    Science.gov (United States)

    Hála, Jindřich; Luxa, Martin; Šimurda, David; Bobčík, Marek; Novák, Ondřej; Rudas, Bartoloměj; Synáč, Jaroslav

    2018-04-01

    This study presents the comparison of aerodynamic performances of two successive designs of the root profiles for the ultra-long rotor blade equipped with a straight fir-tree dovetail. Since aerodynamic and strength requirements laid upon the root section design are contradictory, it is necessary to aerodynamically optimize the design within the limits given by the foremost strength requirements. The most limiting criterion of the static strength is the size of the blade cross-section, which is determined by the number of blades in a rotor and also by the shape and size of a blade dovetail. The aerodynamic design requires mainly the zero incidence angle at the inlet of a profile and in the ideal case ensures that the load does not exceed a limit load condition. Moreover, the typical root profile cascades are transonic with supersonic exit Mach number, therefore, the shape of a suction side and a trailing edge has to respect transonic expansion of a working gas. In this paper, the two variants of root section profile cascades are compared and the aerodynamic qualities of both variants are verified using CFD simulation and two mutually independent experimental methods of measurements (optical and pneumatic).

  1. Structural control by the use of piezoelectric active members

    Science.gov (United States)

    Fanson, J. L.; Chen, J.-C.

    1987-01-01

    Large Space Structures (LSS) exhibit characteristics which make the LSS control problem different form other control problems. LSS will most likely exhibit low frequency, densely spaced and lightly damped modes. In theory, the number of these modes is infinite. Because these structures are flexible, Vibration Suppression (VS) is an important aspect of LSS operation. In terms of VS, the control actuators should be as low mass as possible, have infinite bandwidth, and be electrically powered. It is proposed that actuators be built into the structure as dual purpose structural elements. A piezoelectric active member is proposed for the control of LSS. Such a device would consist of a piezoelectric actuator and sensor for measuring strain, and screwjack actuator in series for use in quasi-static shape control. An experiment simulates an active member using piezoelectric ceramic thin sheet material on a thin, uniform cantilever beam. The feasibility of using the piezoelectric materials for VS on LSS was demonstrated. Positive positive feedback as a VS control strategy was implemented. Multi-mode VS was achieved with dramatic reduction in dynamic response.

  2. 3D straight-stick laparoscopy versus 3D robotics for task performance in novice surgeons: a randomised crossover trial.

    Science.gov (United States)

    Shakir, Fevzi; Jan, Haider; Kent, Andrew

    2016-12-01

    The advent of three-dimensional passive stereoscopic imaging has led to the development of 3D laparoscopy. In simulation tasks, a reduction in error rate and performance time is seen with 3D compared to two-dimensional (2D) laparoscopy with both novice and expert surgeons. Robotics utilises 3D and instrument articulation through a console interface. Robotic trials have demonstrated that tasks performed in 3D produced fewer errors and quicker performance times compared with those in 2D. It was therefore perceived that the main advantage of robotic surgery was in fact 3D. Our aim was to compare 3D straight-stick laparoscopic task performance (3D) with robotic 3D (Robot), to determine whether robotic surgery confers additional benefit over and above 3D visualisation. We randomised 20 novice surgeons to perform four validated surgical tasks, either with straight-stick 3D laparoscopy followed by 3D robotic surgery or in the reverse order. The trial was conducted in two fully functional operating theatres. The primary outcome of the study was the error rate as defined for each task, and the secondary outcome was the time taken to complete each task. The participants were asked to perform the tasks as quickly and as accurately as possible. Data were analysed using SPSS version 21. The median error rate for completion of all four tasks with the robot was 2.75 and 5.25 for 3D with a P value performance time for completion of all four tasks with the robot was 157.1 and 342.5 s for 3D with a P value 3D robotic systems over 3D straight-stick laparoscopy, in terms of reduced error rate and quicker task performance time.

  3. Hysteresis of haptic vertical and straight ahead in healthy human subjects

    Directory of Open Access Journals (Sweden)

    Tarnutzer Alexander A

    2012-09-01

    Full Text Available Abstract Background The subjective haptic vertical (SHV task requires subjects to adjust the roll orientation of an object, mostly in the roll plane, in such a way that it is parallel to perceived direction of gravity. Previously we found a tendency for clockwise rod rotations to deviate counter-clockwise and vice versa, indicating hysteresis. However, the contributing factors remained unclear. To clarify this we characterized the SHV in terms of handedness, hand used, direction of hand rotation, type of grasping (wrap vs. precision grip and gender, and compared findings with perceived straight-ahead (PSA. Healthy subjects repetitively performed adjustments along SHV (n = 21 and PSA (n = 10 in complete darkness. Results For both SHV and PSA significant effects of the hand used and the direction of rod/plate rotation were found. The latter effect was similar for SHV and PSA, leading to significantly larger counter-clockwise shifts (relative to true earth-vertical and objective straight-ahead for clockwise rotations compared to counter-clockwise rotations irrespective of the handedness and the type of grip. The effect of hand used, however, was opposite in the two tasks: while the SHV showed a counter-clockwise bias when the right hand was used and no bias for the left hand, in the PSA a counter-clockwise bias was obtained for the left hand without a bias for the right hand. No effects of grip and handedness (studied for SHV only on accuracy were observed, however, SHV precision was significantly (p  Conclusions Unimanual haptic tasks require control for the hand used and the type of grip as these factors significantly affect task performance. Furthermore, aligning objects with the SHV and PSA resulted in systematic direction-dependent deviations that could not be attributed to handedness, the hand used, or the type of grip. These deviations are consistent with hysteresis and are likely not related to gravitational pull, as they were

  4. A study on the relationship between measurement uncertainty and the size of the disk gauge used to calibrate a straightness measuring system

    International Nuclear Information System (INIS)

    Fujimoto, Ikumatsu; Nishimura, Kunitoshi; Takatuji, Toshiyuki; Pyun, Young-Sik

    2011-01-01

    An autonomous method for calibrating the zero difference for the three-point method of surface straightness measurement is presented and discussed with respect to the relationship between the measurement uncertainty and the size of the disk gauge used for calibration. In this method, the disk gauge is used in two steps. In the first step, the disk gauge rotates a few revolutions and moves parallel to three displacement sensors built into a holder. In the second step, the geometrical parameters between the sensors and the disk gauge are acquired, and the zero differences are computed by our recently proposed algorithm. Finally, the uncertainty of the zero differences is analyzed and simulated numerically, and the relationship between the disk gauge radius and the measurement uncertainty is calculated. The use of a disk gauge of larger radius results in smaller uncertainty of straightness measurement

  5. Position and out-of-straightness measurement of a precision linear air-bearing stage by using a two-degree-of-freedom linear encoder

    International Nuclear Information System (INIS)

    Kimura, Akihide; Gao, Wei; Lijiang, Zeng

    2010-01-01

    This paper presents measurement of the X-directional position and the Z-directional out-of-straightness of a precision linear air-bearing stage with a two-degree-of-freedom (two-DOF) linear encoder, which is an optical displacement sensor for simultaneous measurement of the two-DOF displacements. The two-DOF linear encoder is composed of a reflective-type one-axis scale grating and an optical sensor head. A reference grating is placed perpendicular to the scale grating in the optical sensor head. Two-DOF displacements can be obtained from interference signals generated by the ±1 order diffracted beams from two gratings. A prototype two-DOF linear encoder employing the scale grating with the grating period of approximately 1.67 µm measured the X-directional position and the Z-directional out-of-straightness of the linear air-bearing stage

  6. Learning Style Scales: a valid and reliable questionnaire

    Directory of Open Access Journals (Sweden)

    Abdolghani Abdollahimohammad

    2014-08-01

    Full Text Available Purpose: Learning-style instruments assist students in developing their own learning strategies and outcomes, in eliminating learning barriers, and in acknowledging peer diversity. Only a few psychometrically validated learning-style instruments are available. This study aimed to develop a valid and reliable learning-style instrument for nursing students. Methods: A cross-sectional survey study was conducted in two nursing schools in two countries. A purposive sample of 156 undergraduate nursing students participated in the study. Face and content validity was obtained from an expert panel. The LSS construct was established using principal axis factoring (PAF with oblimin rotation, a scree plot test, and parallel analysis (PA. The reliability of LSS was tested using Cronbach’s α, corrected item-total correlation, and test-retest. Results: Factor analysis revealed five components, confirmed by PA and a relatively clear curve on the scree plot. Component strength and interpretability were also confirmed. The factors were labeled as perceptive, solitary, analytic, competitive, and imaginative learning styles. Cronbach’s α was > 0.70 for all subscales in both study populations. The corrected item-total correlations were > 0.30 for the items in each component. Conclusion: The LSS is a valid and reliable inventory for evaluating learning style preferences in nursing students in various multicultural environments.

  7. Learning Style Scales: a valid and reliable questionnaire.

    Science.gov (United States)

    Abdollahimohammad, Abdolghani; Ja'afar, Rogayah

    2014-01-01

    Learning-style instruments assist students in developing their own learning strategies and outcomes, in eliminating learning barriers, and in acknowledging peer diversity. Only a few psychometrically validated learning-style instruments are available. This study aimed to develop a valid and reliable learning-style instrument for nursing students. A cross-sectional survey study was conducted in two nursing schools in two countries. A purposive sample of 156 undergraduate nursing students participated in the study. Face and content validity was obtained from an expert panel. The LSS construct was established using principal axis factoring (PAF) with oblimin rotation, a scree plot test, and parallel analysis (PA). The reliability of LSS was tested using Cronbach's α, corrected item-total correlation, and test-retest. Factor analysis revealed five components, confirmed by PA and a relatively clear curve on the scree plot. Component strength and interpretability were also confirmed. The factors were labeled as perceptive, solitary, analytic, competitive, and imaginative learning styles. Cronbach's α was >0.70 for all subscales in both study populations. The corrected item-total correlations were >0.30 for the items in each component. The LSS is a valid and reliable inventory for evaluating learning style preferences in nursing students in various multicultural environments.

  8. Partial-limb salvage after persistent infection in the distal femoral prosthesis: straight-plasty - a novel technique

    International Nuclear Information System (INIS)

    Kundu, Z. S.; Gupta, V.; Gogna, P.

    2014-01-01

    A 35 years old female had giant cell tumour (GCT) of the distal femur for which wide resection and distal femoral endoprosthetic replacement was performed. Massive infection of prosthesis required removal and replacement of the prosthesis with nail antibiotic cement spacer, which also proved to be futile. Ultimately the whole of the infected thigh had to be excised. The limb could be preserved partially using straight-plasty instead of amputation. Patient is well rehabilitated and doing well at a follow-up of 3 years. (author)

  9. FLOW PHYSICS OF 3-BLADED STRAIGHT CHORD H-DARRIEUS WIND TURBINE

    Directory of Open Access Journals (Sweden)

    Rajat Gupta

    2013-06-01

    Full Text Available Steady-state two-dimensional Computational Fluid Dynamics (CFD simulations were performed using Fluent 6.0 software to analyze the flow physics of 3-bladed straight chord H-Darrieus wind turbine having blade twist of 300 for 10% of its chord at the trailing ends. The flow was simulated using finite volume method coupled with moving mesh technique to solve mass and momentum conservation equations. The standard k-ε turbulence model with enhanced wall condition was used. Second-order upwind discretization scheme was adopted for pressure-velocity coupling of the flow. Flow physics of the turbine was analyzed with the help of pressure and velocity contours. It was found that velocity magnitude decreases from upstream to downstream side across the turbine, which will cause overall lift for the turbine. Further, blade twist at the trailing ends creates circulations that interact with the blades in a direction opposite to the direction of rotation of the turbine which would enhance power production for the three bladed turbine.

  10. FLOW PHYSICS OF 3-BLADED STRAIGHT CHORD H- DARRIEUS WIND TURBINE

    Directory of Open Access Journals (Sweden)

    Rajat Gupta

    2013-01-01

    Full Text Available Steady-state two-dimensional Computational Fluid Dynamics (CFD simulations were performed using Fluent 6.0 software to analyze the flow physics of 3-bladed straight chord H-Darrieus wind turbine having blade twist of 300 for 10% of its chord at the trailing ends. The flow was simulated using finite volume method coupled with moving mesh technique to solve mass and momentum conservation equations. The standard k- ε turbulence model with enhanced wall condition was used. Second-order upwind discretization scheme was adopted for pressure-velocity coupling of the flow. Flow physics of the turbine was analyzed with the help of pressure and velocity contours. It was found that velocity magnitude decreases from upstream to downstream side across the turbine, which will cause overall lift for the turbine. Further, blade twist at the trailing ends creates circulations that interact with the blades in a direction opposite to the direction of rotation of the turbine which would enhance power production for the three bladed turbine.

  11. A charge-dependent mechanism is responsible for the dynamic accumulation of proteins inside nucleoli.

    Science.gov (United States)

    Musinova, Yana R; Kananykhina, Eugenia Y; Potashnikova, Daria M; Lisitsyna, Olga M; Sheval, Eugene V

    2015-01-01

    The majority of known nucleolar proteins are freely exchanged between the nucleolus and the surrounding nucleoplasm. One way proteins are retained in the nucleoli is by the presence of specific amino acid sequences, namely nucleolar localization signals (NoLSs). The mechanism by which NoLSs retain proteins inside the nucleoli is still unclear. Here, we present data showing that the charge-dependent (electrostatic) interactions of NoLSs with nucleolar components lead to nucleolar accumulation as follows: (i) known NoLSs are enriched in positively charged amino acids, but the NoLS structure is highly heterogeneous, and it is not possible to identify a consensus sequence for this type of signal; (ii) in two analyzed proteins (NF-κB-inducing kinase and HIV-1 Tat), the NoLS corresponds to a region that is enriched for positively charged amino acid residues; substituting charged amino acids with non-charged ones reduced the nucleolar accumulation in proportion to the charge reduction, and nucleolar accumulation efficiency was strongly correlated with the predicted charge of the tested sequences; and (iii) sequences containing only lysine or arginine residues (which were referred to as imitative NoLSs, or iNoLSs) are accumulated in the nucleoli in a charge-dependent manner. The results of experiments with iNoLSs suggested that charge-dependent accumulation inside the nucleoli was dependent on interactions with nucleolar RNAs. The results of this work are consistent with the hypothesis that nucleolar protein accumulation by NoLSs can be determined by the electrostatic interaction of positively charged regions with nucleolar RNAs rather than by any sequence-specific mechanism. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. On merging Acer sections Rubra and Hyptiocarpa: Molecular and morphological evidence.

    Science.gov (United States)

    Harris, A J; Chen, Yousheng; Olsen, Richard T; Lutz, Sue; Wen, Jun

    2017-01-01

    In this study, we expanded Acer sect. Rubra Pax to include A. sect. Hyptiocarpa Fang. Traditionally, section Rubra comprises two iconic species, Acer rubrum Linnaeus (red maple) and A. saccharinum Linnaeus (silver maple), of eastern North American forests as well as the rare Japanese montane species, A. pycnanthum K. Koch. Section Hyptiocarpa consists of A. laurinum Hasskarl and A. pinnatinervium Merrill, which occur in subtropical and tropical regions of southwestern China to southeast Asia. Here, we confirm prior phylogenetic results showing the close relationship between sects. Rubra and Hyptiocarpa , and we use scanning electron microscopy to demonstrate that leaves of species within these sections have similar arrangements of cuticular waxes, which account for the silvery color of their abaxial surfaces. We describe that the sections also share labile sex expression; inflorescences that range from compound racemose thyrses, to racemes or umbels and that may have undergone evolutionary reduction; and several features of their fruits, such as seed locules without keels, basal portion of wings straight, acute attachment angle between mericarps, and production of some mericarps that are seedless and partially developed at maturity. Our expansion of sect. Rubra to include sect. Hyptiocarpa better elucidates the biogeographic and evolutionary history of these species. Additionally, we show that A. laurinum and A. pinnatinervium have intergrading morphology and are probably synonymous, but we note that further studies are required to conclude their taxonomic status.

  13. Bacterial chondronecrosis with osteomyelitis in broilers: influence of sires and straight-run versus sex-separate rearing.

    Science.gov (United States)

    Wideman, R F; Al-Rubaye, A; Reynolds, D; Yoho, D; Lester, H; Spencer, C; Hughes, J D; Pevzner, I Y

    2014-07-01

    Two experiments (E1, E2) were conducted to compare the influence of sires (sire A on dam C vs. sire B on dam C) and straight-run versus sex-separate rearing on the incidence of bacterial chondronecrosis with osteomyelitis (BCO) in broilers. Fertile eggs from commercial breeder flocks were incubated and hatched at the University of Arkansas Poultry Research Hatchery. Male and female chicks were reared together (straight-run) or separately (sex-separate) in 3 × 3 m pens on litter or flat wire flooring with 65 (E1) or 60 (E2) birds per pen. Necropsies revealed lesions that are pathognomonic for BCO in ≥98% of the birds that became lame. The SigmaStat Z-test was used to compare cumulative BCO incidences through 8 wk of age. For birds reared on litter, the incidences of BCO were low regardless of cross or sex (range: 1.7 to 5.1%; P ≥ 0.6). Within a cross and sex, rearing the broilers straight-run versus sex-separate on wire flooring did not significantly affect the incidence of BCO. Significant incidences of BCO did not develop until after d 40. Males from the sire A cross developed a higher incidence of BCO than males from the sire B cross in E1 (27 vs. 17%, respectively; P = 0.009) but not in E2 (28.5 vs. 22.6%, respectively; P = 0.141). In both experiments, males from the sire A cross developed higher incidences of BCO than females from the sire B cross (27 vs. 11.9%, in E1; 28.5 vs. 14.8%, in E2). With the sexes pooled, broilers from the sire A cross consistently developed higher incidences of BCO than broilers from the sire B cross (21.4 vs. 14.9%, P = 0.005 in E1; 26.5 vs. 18.7%, P = 0.003 in E2). High susceptibilities to both femoral head (all femoral head necrosis = 66 to 85% incidences) and tibial head (all tibial head necrosis = 81 to 96% incidences) BCO lesions were demonstrated in lame birds from both sexes and crosses. This study supports a sire influence on the susceptibility of broilers to BCO. Sire lines can be chosen to reduce BCO susceptibility

  14. Outcome after surgical treatment for lumbar spinal stenosis: the lumbar extension test is not a predictive factor

    DEFF Research Database (Denmark)

    Westergaard, Lars; Hauerberg, John; Springborg, Jacob B

    2009-01-01

    STUDY DESIGN: A prospective clinical study. OBJECTIVES: To investigate the predictive value of the lumbar extension test for outcome after surgical treatment of lumbar spinal stenosis (LSS). SUMMARY OF BACKGROUND DATA: Studies have indicated that aggravation of the symptoms from LSS by extension...... of the lumbar spine has predictive value for the outcome after decompression. The aim of this study was to investigate this theory in a larger group of patients. METHODS: One hundred forty-six consecutive patients surgically treated for LSS were included in the study. The clinical condition was recorded before...... has no predictive value for the outcome after surgical treatment of LSS....

  15. Paired Straight Hearth Furnace - Transformational Ironmaking Process

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Wei-Kao [McMaster Univ., Hamilton, ON (Canada); Debski, Paul [Andritz Metals Inc.,Canonsburg, PA (United States)

    2014-11-19

    The U. S. steel industry has reduced its energy intensity per ton of steel shipped by 33% since 1990. However, further significant gains in energy efficiency will require the development of new, transformational iron and steelmaking processes. The Paired Straight Hearth Furnace (PSH) process is an emerging alternative high productivity, direct reduced iron (DRI) technology that may achieve very low fuel rates and has the potential to replace blast furnace ironmaking. The PSH furnace can operate independently or may be coupled with other melting technologies to produce liquid hot metal that is both similar to blast furnace iron and suitable as a feedstock for basic oxygen steelmaking furnaces. The PSH process uses non-metallurgical coal as a reductant to convert iron oxides such as iron ore and steelmaking by-product oxides to DRI pellets. In this process, a multi-layer, nominally 120mm tall bed of composite “green balls” made from oxide, coal and binder is built up and contained within a moving refractory hearth. The pellet bed absorbs radiant heat energy during exposure to the high temperature interior refractory surfaces of the PSH while generating a strongly reducing gas atmosphere in the bed that yields a highly metalized DRI product. The PSH concept has been well tested in static hearth experiments. A moving bed design is being developed. The process developers believe that if successful, the PSH process has the potential to replace blast furnaces and coke ovens at a fraction of the operating and capital cost while using about 30% less energy relative to current blast furnace technology. DRI output could also feed electric arc furnaces (EAFs) by displacing a portion of the scrap charge.

  16. The Effect of Straight-Line and Accelerated Depreciation Rules on Risky Investment Decisions—An Experimental Study

    Directory of Open Access Journals (Sweden)

    Hagen Ackermann

    2016-10-01

    Full Text Available The aim of this study is to analyze how depreciation rules influence the decision behavior of investors. For this purpose, we conduct a laboratory experiment in which participants decide on the composition of an asset portfolio in different choice situations. Using an experimental setting with different payment periods, we show that accelerated compared to straight-line depreciation can increase the willingness to invest as hypothesized by theory. However, this expected behavior is only observed in a more complex environment (with a subsidy and not in a less complex environment (without a subsidy.

  17. Implementation of the Hough transform for 3D recognition of the straight tracks in drift chambers

    International Nuclear Information System (INIS)

    Bel'kov, A.A.

    2001-01-01

    This work is devoted to the development of the method for 3D reconstruction of the charged-particle straight tracks in the tracking systems consisting of the drift-chamber stereo layers. The method is based on the modified Hough transform with taking into account the measurements of drift distance. The proposed program realization of the method provides the time-consuming optimization of event processing, the stable performance of the algorithm and high efficiency of the track recognition under large track-occupancy of the detector as well as under high level of noisy and dead channels

  18. Full-vectorial propagation model and modified effective mode area of four-wave mixing in straight waveguides

    DEFF Research Database (Denmark)

    Guo, Kai; Friis, Søren Michael Mørk; Christensen, Jesper Bjerge

    2017-01-01

    We derive from Maxwell's equations full-vectorial nonlinear propagation equations of four-wave mixing valid in straight semiconductor-on-insulator waveguides. Special attention is given to the resulting effective mode area, which takes a convenient form known from studies in photonic crystal fibers......, but has not been introduced in the context of integrated waveguides. We show that the difference between our full-vectorial effective mode area and the scalar equivalent often referred to in the literature may lead to mistakes when evaluating the nonlinear refractive index and optimizing designs of new...

  19. Implementation of the Hough Transform for 3D Recognition of the Straight Tracks in Drift Chambers

    CERN Document Server

    Belkov, A A

    2001-01-01

    This work is devoted to the development of the method for 3D reconstruction of the charged-particle straight tracks in the tracking systems consisting of the drift-chamber stereo layers. The method is based on the modified Hough transform with taking into account the measurements of drift distance. The proposed program realization of the method provides the time-consuming optimization of event processing, the stable performance of algorithm and high efficiency of the track recognition under large track-occupancy of detector as well as under high level of noisy and dead channels.

  20. "Scared Straight" and other juvenile awareness programs for preventing juvenile delinquency.

    Science.gov (United States)

    Petrosino, A; Turpin-Petrosino, C; Buehler, J

    2002-01-01

    'Scared Straight' and other programmes involve organised visits to prison by juvenile delinquents or children at risk for criminal behavior. programmes are designed to deter participants from future offending through first-hand observation of prison life and interaction with adult inmates. These programmes remain in use world-wide despite studies and reviews questioning their effectiveness. To assess the effects of programmes comprising organised visits to prisons by juvenile delinquents (officially adjudicated or convicted by a juvenile court) or pre-delinquents (children in trouble but not officially adjudicated as delinquents), aimed at deterring them from criminal activity. Handsearching by the first author in identifying randomised field trials 1945-1993 relevant to criminology was augmented by structured searches of 16 electronic data bases, including the Campbell SPECTR database of trials and the Cochrane CCTR. Experts in the field were consulted and relevant citations were followed up. Studies that tested the effects of any program involving the organised visits of juvenile delinquents or children at-risk for delinquency to penal institutions were included. Studies that included overlapping samples of juvenile and young adults (e.g. ages 14-20) were included. We only considered studies that randomly or quasi-randomly (i.e. alternation) assigned participants to conditions. Each study had to have a no-treatment control condition with at least one outcome measure of "post-visit" criminal behavior. We report narratively on the nine eligible trials. We conducted one meta-analysis of post-intervention offending rates using official data. Information from other sources (e.g. self-report) was either missing from some studies or critical information was omitted (e.g. standard deviations). We examined the immediate post-treatment effects (i.e. "first-effects") by computing Odds Ratios (OR) for data on proportions of each group re-offending, and assumed both fixed and