WorldWideScience

Sample records for straight projection rays

  1. Spherical Projection Based Straight Line Segment Extraction for Single Station Terrestrial Laser Point Cloud

    Directory of Open Access Journals (Sweden)

    ZHANG Fan

    2015-06-01

    Full Text Available Due to the discrete distribution computing errors and lack of adaptability are ubiquitous in the current straight line extraction for TLS data methods. A 3D straight line segment extraction method is proposed based on spherical projection for single station terrestrial laser point clouds. Firstly, horizontal and vertical angles of each laser point are calculated by means of spherical coordinates, intensity panoramic image according to the two angles is generated. Secondly, edges which include straight line features are detected from intensity panoramic image by using of edge detection algorithm. Thirdly, great circles are detected from edges of panoramic image using spherical Hough transform. According to the axiom that a straight line segment in 3D space is a spherical great circle after spherical projection, detecting great circles from spherical projected data sets is essentially detecting straight line segments from 3D data sets without spherical projection. Finally, a robust 3D straight line fitting method is employed to fitting the straight lines and calculating parameters of the straight line segments. Experiments using different data sets and comparison with other methods show the accuracy and applicability of the proposed method.

  2. Safeguards and security benefits of project straight-line

    International Nuclear Information System (INIS)

    Jaeger, C.D.; Waddoups, I.G.

    1995-01-01

    As a result of a number of events the inventory of fissile materials no longer in nuclear weapons in the United States is increasing. This has led to a growing concern regarding the potential for theft and/or diversion and accountability of this material. Straight-Line is a project whose purpose is to demonstrate a site-independent system to monitor stored nuclear material (e.g. plutonium) and integrate the collection, processing and dissemination of information regarding this material. Safeguards and security (S ampersand S) goals of this project include data transfer of information on nuclear material to appropriate users to enhance S ampersand S, continuous on-line accountability, reduction of hands-on access to nuclear materials, incorporation of information security technologies, and early detection of tampering or unauthorized material movement. This paper addresses threat considerations, S ampersand S requirements, S ampersand S objectives, and issues for the Straight-Line project. S ampersand S features and benefits of this project are discussed with respect to existing item monitoring systems and/or other material tracking systems being developed

  3. Insertion device development in the X13 straight of the NSLS X-Ray Ring

    International Nuclear Information System (INIS)

    Stefan, P.M.; Krinsky, S.; Kao, C.C.; Rakowsky, G.; Singh, O.; Solomon, L.

    1997-01-01

    On the NSLS X-Ray Storage Ring, the X13 straight section and beamline have been used for insertion-device-related R and D since 1990. The authors will describe three important projects: The Prototype Small-Gap Undulator (PSGU), the In-Vacuum Undulator (IVUN), and the Time Varying Elliptically Polarized Wiggler (EPW). The PSGU has successfully operated with a vertical aperture of only 3 mm, with minimal reduction in electron beam lifetime. The EPW has successfully run during regular user operations while switching at either 2 Hz or 100 Hz, with no adverse effects on other experiments. The IVUN project is a collaboration between NSLS and Spring-8, and installation is scheduled for May 1997

  4. Gamma-ray streaming in straight pipes and bent ducts

    International Nuclear Information System (INIS)

    Eid, M.; Diop, C.M.; Nimal, J.C.

    1985-04-01

    An important shielding problem is the gamma-ray streaming through voids. These problems are encountered in the reactors and reprocessing plants. A Monte Carlo method has been choosed as one of the most powerful technics to solve this kind of problems. Here in that frame, a biasing system which is adapted for two types of geometries is proposed: straight pipes and bent ducts. A code has been written applying this technique. The numerical results obained show the efficiency and the very good economy of the method proposed. It is hoped to extend the method to deal with more complex geometries and polykinetic situation as well

  5. Status of PF-ring commissioning after the reconstruction for the straight-sections upgrade

    International Nuclear Information System (INIS)

    Tanimoto, Yasunori; Miyauchi, Hiroshi; Honda, Tohru; Kobayashi, Yukinori

    2006-01-01

    The upgrade project of the straight sections at the PF-ring enables the reinforcement of insertion devices and their beamlines. As a main part of this project, a large-scale reconstruction of the storage ring was carried out from March to September in 2005. The lattice configuration was modified to create short straight sections of 1.4 m and to extend the existing straight sections. Optical functions of the short sections were optimized for short-gap mini-pole undulators as X-ray sources. The first mini-pole undulator SGU no.17 has been operated for a protein crystallography. A recommissioning of the ring was conducted for about one month, and user experiments were restarted on 18th October 2005 according to schedule. The recovery of the beam lifetime due to the process of the vacuum scrubbing has been favorably progressed. (author)

  6. Ray-tracing analysis of electron-cyclotron-resonance heating in straight stellarators

    International Nuclear Information System (INIS)

    Kato, K.

    1983-05-01

    A ray-tracing computer code is developed and implemented to simulate electron cyclotron resonance heating (ECRH) in stellarators. A straight stellarator model is developed to simulate the confinement geometry. Following a review of ECRH, a cold plasma model is used to define the dispersion relation. To calculate the wave power deposition, a finite temperature damping approximation is used. 3-D ray equations in cylindrical coordinates are derived and put into suitable forms for computation. The three computer codes, MAC, HERA, and GROUT, developed for this research, are described next. ECRH simulation is then carried out for three models including Heliotron E and Wendelstein VII A. Investigated aspects include launching position and mode scan, frequency detuning, helical effects, start-up, and toroidal effects. Results indicate: (1) an elliptical waveguide radiation pattern, with its long axis oriented half-way between the toroidal axis and the saddle point line, is more efficient than a circular one; and (2) mid-plane, high field side launch is favored for both O- and X-waves

  7. Commissioning of the PF Ring after the Reconstruction for the Straight-sections Upgrade

    International Nuclear Information System (INIS)

    Honda, T.; Asaoka, S.; Cheng, W. X.; Haga, K.; Harada, K.; Hori, Y.; Izawa, M.; Kasuga, T.; Kobayashi, Y.; Maezawa, H.; Mishina, A.; Mitsuhashi, T.; Miyajima, T.; Miyauchi, H.; Nagahashi, S.; Nogami, T.; Obina, T.; Pak, C. O.; Sakanaka, S.; Sasaki, H.

    2007-01-01

    At the 2.5-GeV ring of the Photon Factory, a large reconstruction of the lattice around the straight sections has been accomplished in 2005. Thus reconstruction is the main part of the straight-sections upgrade project to rebuild existing undulators and to increase the number of undulator beamlines. As a result of the reconstruction, four short straight sections have been newly created and the lengths of the existing straight sections have been much extended. To exploit the new straight sections, short-period narrow-gap undulators which have a sufficiently high brilliance in hard x-ray range have been developed. The reconstruction work of the ring was completed in a seven-month shutdown from March to September, 2005. In the area over two thirds of the storage ring, all the quadrupole magnets and all the beam ducts have been renewed and rearranged to construct the new lattice. Recommissioning of the storage ring was finished at the end of October, 2005. Though we made no in-situ baking for the beam ducts, recovery of the beam lifetime has favorably progressed due to the vacuum scrubbing by the synchrotron radiation

  8. On evolutionary ray-projection dynamics

    NARCIS (Netherlands)

    Joosten, Reinoud A.M.G.; Roorda, Berend

    2011-01-01

    We introduce the ray-projection dynamics in evolutionary game theory by employing a ray projection of the relative fitness (vector) function, i.e., a projection unto the unit simplex along a ray through the origin. Ray-projection dynamics are weakly compatible in the terminology of Friedman

  9. Straight leg elevation to rule out pelvic injury.

    Science.gov (United States)

    Bolt, Caroline; O'Keeffe, Francis; Finnegan, Pete; Dickson, Kristofer; Smit, De Villiers; Fitzgerald, Mark C; Mitra, Biswadev

    2018-02-01

    Pelvic x-ray is frequently used as a screening tool during initial assessment of injured patients. However routine use in the awake and alert blunt trauma patient may be questioned due to low yield. We propose a clinical tool that may avoid unnecessary imaging by examining whether the ability to straight leg raise, without pain, can rule out pelvic injury. We conducted a prospective cohort study with the exposure variables of ability to straight leg raise and presence of pain on doing so, and presence of pelvic fracture on x-ray as the primary outcome variable. Of the 328 participants, 35 had pelvic fractures, and of these 32 were either unable to straight leg raise, or had pain on doing so, with a sensitivity of 91.43% (95% CI: 76.94-98.2%) and a negative predictive value of 98.57% (95% CI: 95.88-99.70%). The 3 participants with a pelvic fracture who could straight leg raise with no pain, all had a GCS of less than 15, and therefore, among the sub-group of patients with GCS15, a 100% sensitivity and 100% negative predictive value for straight leg raise with no pain to rule out pelvic fracture was demonstrated. Among awake, alert patients, painless straight leg raise can exclude pelvic fractures and be incorporated into initial examination during reception and resuscitation of injured patients. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  10. A new straight accelerator tube with U diaphragm

    International Nuclear Information System (INIS)

    Liu Jinhong; Lai Weiquan; Deng Yushen; Zhang Jidong

    1994-01-01

    After calculating the potential distribution and the particle trajectories in electrostatic accelerator tubes, a new straight tube with U diaphragm to suppress secondary particles is proposed. It's properties are demonstrated by the high voltage tests and the γ-rays measurements in the accelerator

  11. Comparison of anatomic vs. straight femoral stem design in total hip replacement - femoral canal fill in vivo.

    Science.gov (United States)

    de Boer, Friso A; Sariali, Elhadi

    2017-05-12

    The femoral canal fill between an anatomic and a straight prosthesis design in cementless total hip arthroplasty (THA) was compared. We hypothesised that the anatomic SPS stem has higher proximal fill and lesser distal fill than the straight stem. The femoral canal fill was measured on 3 months routine postoperative x-rays at 5 levels of the stem in 50 consecutive patients, aged 35-83 years, who underwent 56 THA procedures by a single surgeon in this hospital. 22 patients received a straight design Ceramconcept Global stem, 34 patients received an anatomic design Symbios SPS stem. Both anteroposterior (AP) and lateral x-rays were combined to suggest a 3-D measurement. On the AP x-rays, the canal fill was significantly higher using the anatomic design stem at the proximal measurement levels, and was significantly higher at the distal levels using the straight stem. With the AP and lateral x-rays combined, the canal fill at the proximal levels was also significantly higher in the anatomic groups, nonsignificantly lower at the central level and significantly lower at the distal levels. In THA surgery, achieving high fill at the metaphysis of the femur and less fill at the diaphysis has been suggested to result in satisfactory outcome and high stability of the prosthesis. This study demonstrated that, compared to straight stem design, an anatomically designed stem has a significantly higher metaphyseal femoral canal fill.

  12. Registration of airborne LiDAR data and aerial images based on straight lines and POS data

    Science.gov (United States)

    Du, Quanye; Xu, Biao; Cao, Hui

    2009-10-01

    This paper presents a registration method which based on straight lines primitive. Firstly, 2D straight lines are extracted from aerial images using Canny operator and straight line fitting. In the similar way, 3D straight lines are extracted from LiDAR range images which derive from laser scanning point cloud. Secondly, 3D straight lines are projected to aerial images using collinearity equations and Position and Orientation System (POS) data. Then the corresponding lines are determined by straight line error. At last, each image's new exterior orientation elements are calculated by generalized point (straight line) photogrammetry.

  13. X-ray fluorescence imaging with polycapillary X-ray optics

    International Nuclear Information System (INIS)

    Yonehara, Tasuku; Yamaguchi, Makoto; Tsuji, Kouichi

    2010-01-01

    X-ray fluorescence spectrometry imaging is a powerful tool to provide information about the chemical composition and elemental distribution of a specimen. X-ray fluorescence spectrometry images were conventionally obtained by using a μ-X-ray fluorescence spectrometry spectrometer, which requires scanning a sample. Faster X-ray fluorescence spectrometry imaging would be achieved by eliminating the process of sample scanning. Thus, we developed an X-ray fluorescence spectrometry imaging instrument without sample scanning by using polycapillary X-ray optics, which had energy filter characteristics caused by the energy dependence of the total reflection phenomenon. In the present paper, we show that two independent straight polycapillary X-ray optics could be used as an energy filter of X-rays for X-ray fluorescence. Only low energy X-rays were detected when the angle between the two optical axes was increased slightly. Energy-selective X-ray fluorescence spectrometry images with projection mode were taken by using an X-ray CCD camera equipped with two polycapillary optics. It was shown that Fe Kα (6.40 keV) and Cu Kα (8.04 keV) could be discriminated for Fe and Cu foils.

  14. Straight-Line: A nuclear material storage information management system

    International Nuclear Information System (INIS)

    Nilsen, C.; Mangan, D.

    1995-01-01

    Sandia National Laboratories is developing Straight-Line -- a pilot system to demonstrate comprehensive monitoring of nuclear material in storage. Straight-Line is an integrated system of sensors providing information that will enhance the safety, security, and international accountability of stored nuclear material. The goals of this effort are to: (1) Provide the right sensor information to the right user immediately. (2) Reduce the expenses, risks, and frequency of human inspection of the material. (3) Provide trustworthy data to international inspectors to minimize their need to make on site inspections. In pursuit of these goals, Straight-Line unites technology from Sandia's Authenticated Item Monitoring System (AIMS) and other programs to communicate the authenticated status of the monitored item back to central magazine receivers. Straight-Line, however, incorporates several important features not found in previous systems: (1) Information Security -- the ability to collect and safely disseminate both classified and unclassified sensor data to users on a need-to-know basis. (2) Integrate into a single system the monitoring needs of safety, security, and international accountability. (3) Incorporate the use of sensors providing analog or digital output. This paper will present the overall architecture and status of the Straight-Line project

  15. Straight-Line: A nuclear material storage information management system

    Energy Technology Data Exchange (ETDEWEB)

    Nilsen, C.; Mangan, D.

    1995-07-01

    Sandia National Laboratories is developing Straight-Line -- a pilot system to demonstrate comprehensive monitoring of nuclear material in storage. Straight-Line is an integrated system of sensors providing information that will enhance the safety, security, and international accountability of stored nuclear material. The goals of this effort are to: (1) Provide the right sensor information to the right user immediately. (2) Reduce the expenses, risks, and frequency of human inspection of the material. (3) Provide trustworthy data to international inspectors to minimize their need to make on site inspections. In pursuit of these goals, Straight-Line unites technology from Sandia`s Authenticated Item Monitoring System (AIMS) and other programs to communicate the authenticated status of the monitored item back to central magazine receivers. Straight-Line, however, incorporates several important features not found in previous systems: (1) Information Security -- the ability to collect and safely disseminate both classified and unclassified sensor data to users on a need-to-know basis. (2) Integrate into a single system the monitoring needs of safety, security, and international accountability. (3) Incorporate the use of sensors providing analog or digital output. This paper will present the overall architecture and status of the Straight-Line project.

  16. Simulation and analysis of the transmission properties of curved-straight neutron guide systems

    International Nuclear Information System (INIS)

    Copley, J.R.D.; Mildner, D.F.R.

    1992-01-01

    This paper reports that the spatial intensity distribution of neutrons emerging from a curved guide is far from uniform, particularly at short wavelengths, and curved guides are sometimes followed by a straight section of guide to make the intensity distribution more uniform. The behavior of neutrons within curved-straight neutron guide systems is examined using both ray-tracing and analytical approaches to the problem. The intensity distribution within the straight guide tends to wash from one side of the guide to the other. The amplitude of this transverse wave decreases with increasing guide length, and the characteristic length of the wave decreases with increasing neutron wavelength

  17. Straight-Line -- A nuclear material storage information management system

    International Nuclear Information System (INIS)

    Nilsen, C.; Mangan, D.

    1995-01-01

    Sandia National Laboratories is developing Straight-Line -- a pilot system to demonstrate comprehensive monitoring of nuclear material in storage. Straight-Line is an integrated system of sensors providing information that will enhance the safety, security, and international accountability of stored nuclear material. The goals of this effort are to (1) Provide the right sensor information to the right user in a timely manner. (2) Reduce the expenses, risks, and frequency of human inspection of the material. (3) Provide trustworthy data to international inspectors to minimize their need to make on site inspections. In pursuit of these goals, Straight-Line unites technology from Sandia's Authenticated Item Monitoring System (AIMS) and other programs to communicate the authenticated status of the monitored item back to central magazine receivers. Straight-Line, however, incorporates several important features not found in previous systems: (1) Information Security -- the ability to collect and safely disseminate both classified and unclassified sensor data to users on a need-to-know basis. (2) Integrate into a single system the monitoring needs of safety, security, and international accountability. (3) Incorporate the use of sensors providing analog or digital output. This paper will present the overall architecture and status of the Straight-Line project

  18. Straight-Line -- A nuclear material storage information management system

    Energy Technology Data Exchange (ETDEWEB)

    Nilsen, C. [Sandia National Labs., Livermore, CA (United States); Mangan, D. [Sandia National Labs., Albuquerque, NM (United States)

    1995-12-31

    Sandia National Laboratories is developing Straight-Line -- a pilot system to demonstrate comprehensive monitoring of nuclear material in storage. Straight-Line is an integrated system of sensors providing information that will enhance the safety, security, and international accountability of stored nuclear material. The goals of this effort are to (1) Provide the right sensor information to the right user in a timely manner. (2) Reduce the expenses, risks, and frequency of human inspection of the material. (3) Provide trustworthy data to international inspectors to minimize their need to make on site inspections. In pursuit of these goals, Straight-Line unites technology from Sandia`s Authenticated Item Monitoring System (AIMS) and other programs to communicate the authenticated status of the monitored item back to central magazine receivers. Straight-Line, however, incorporates several important features not found in previous systems: (1) Information Security -- the ability to collect and safely disseminate both classified and unclassified sensor data to users on a need-to-know basis. (2) Integrate into a single system the monitoring needs of safety, security, and international accountability. (3) Incorporate the use of sensors providing analog or digital output. This paper will present the overall architecture and status of the Straight-Line project.

  19. Standing "Straight" up to Homophobia: Straight Allies' Involvement in GSAs

    Science.gov (United States)

    Lapointe, Alicia Anne

    2015-01-01

    This qualitative study captures the experiences of four straight allies' and one gay youth involvement in gay--straight alliances (GSAs) at their Ontario, Canada, high schools. Participants' motivations for becoming GSA members and their roles as allies are examined. Queer theoretical perspectives, as espoused by Britzman (1995, 1998) and Linville…

  20. Synchrotron radiation sources and condensers for projection x-ray lithography

    International Nuclear Information System (INIS)

    Murphy, J.B.; MacDowell, A.A.; White, D.L.; Wood, O.R. II

    1992-01-01

    The design requirements for a compact electron storage ring that could be used as a soft x-ray source for projection lithography are discussed. The design concepts of the x-ray optics that are required to collect and condition the radiation in divergence, uniformity and direction to properly illuminate the mask and the particular x-ray projection camera used are discussed. Preliminary designs for an entire soft x-ray projection lithography system using an electron storage ring as a soft X-ray source are presented. It is shown that by combining the existing technology of storage rings with large collection angle condensers, a powerful and reliable source of 130 Angstrom photons for production line projection x-ray lithography is possible

  1. Straight, white teeth as a social prerogative.

    Science.gov (United States)

    Khalid, Abeer; Quiñonez, Carlos

    2015-06-01

    A distinguishing feature of North American society is preoccupation with self-image, as seen in the ritualistic nature of bodily practices aimed at constantly improving the body. Nowhere is this more apparent than in the prevailing fixation with straight, white teeth. While there is an ever-expanding literature on the sociology of body, very little has been written on teeth in this context. Using literature from anthropology, biology, dentistry, sociology and social psychology, this study attempts to answer: (1) Why have straight, white teeth become a beauty ideal in North American society? (2) What is the basis for this ideal? (3) How is this ideal propagated? It demonstrates that dental aesthetic tendencies are biologically, culturally and socially patterned. Concepts from the works of Pierre Bourdieu and Michel Foucault are used to illustrate how straight, white teeth contribute towards reinforcing class differences and how society exercises a disciplinary power on individuals through this ideal. It is concluded that modified teeth are linked to self and identity that are rooted in social structure. Moreover, teeth demonstrate the ways in which class differences are embodied and projected as symbols of social advantage or disadvantage. Implications on professional, public health, sociological and political levels are considered. © 2015 Foundation for the Sociology of Health & Illness.

  2. Straight scaling FFAG beam line

    International Nuclear Information System (INIS)

    Lagrange, J.-B.; Planche, T.; Yamakawa, E.; Uesugi, T.; Ishi, Y.; Kuriyama, Y.; Qin, B.; Okabe, K.; Mori, Y.

    2012-01-01

    Fixed field alternating gradient (FFAG) accelerators are recently subject to a strong revival. They are usually designed in a circular shape; however, it would be an asset to guide particles with no overall bend in this type of accelerator. An analytical development of a straight FFAG cell which keeps zero-chromaticity is presented here. A magnetic field law is thus obtained, called “straight scaling law”, and an experiment has been conducted to confirm this zero-chromatic law. A straight scaling FFAG prototype has been designed and manufactured, and horizontal phase advances of two different energies are measured. Results are analyzed to clarify the straight scaling law.

  3. Straight scaling FFAG beam line

    Science.gov (United States)

    Lagrange, J.-B.; Planche, T.; Yamakawa, E.; Uesugi, T.; Ishi, Y.; Kuriyama, Y.; Qin, B.; Okabe, K.; Mori, Y.

    2012-11-01

    Fixed field alternating gradient (FFAG) accelerators are recently subject to a strong revival. They are usually designed in a circular shape; however, it would be an asset to guide particles with no overall bend in this type of accelerator. An analytical development of a straight FFAG cell which keeps zero-chromaticity is presented here. A magnetic field law is thus obtained, called "straight scaling law", and an experiment has been conducted to confirm this zero-chromatic law. A straight scaling FFAG prototype has been designed and manufactured, and horizontal phase advances of two different energies are measured. Results are analyzed to clarify the straight scaling law.

  4. Straight until proven gay: A systematic bias toward straight categorizations in sexual orientation judgments.

    Science.gov (United States)

    Lick, David J; Johnson, Kerri L

    2016-06-01

    Perceivers achieve above chance accuracy judging others' sexual orientations, but they also exhibit a notable response bias by categorizing most targets as straight rather than gay. Although a straight categorization bias is evident in many published reports, it has never been the focus of systematic inquiry. The current studies therefore document this bias and test the mechanisms that produce it. Studies 1-3 revealed the straight categorization bias cannot be explained entirely by perceivers' attempts to match categorizations to the number of gay targets in a stimulus set. Although perceivers were somewhat sensitive to base rate information, their tendency to categorize targets as straight persisted when they believed each target had a 50% chance of being gay (Study 1), received explicit information about the base rate of gay targets in a stimulus set (Study 2), and encountered stimulus sets with varying base rates of gay targets (Study 3). The remaining studies tested an alternate mechanism for the bias based upon perceivers' use of gender heuristics when judging sexual orientation. Specifically, Study 4 revealed the range of gendered cues compelling gay judgments is smaller than the range of gendered cues compelling straight judgments despite participants' acknowledgment of equal base rates for gay and straight targets. Study 5 highlighted perceptual experience as a cause of this imbalance: Exposing perceivers to hyper-gendered faces (e.g., masculine men) expanded the range of gendered cues compelling gay categorizations. Study 6 linked this observation to our initial studies by demonstrating that visual exposure to hyper-gendered faces reduced the magnitude of the straight categorization bias. Collectively, these studies provide systematic evidence of a response bias in sexual orientation categorization and offer new insights into the mechanisms that produce it. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  5. Development of improved x-ray optics for analytical x-ray microbeams. CRADA final report for CRADA Number Y-1294-0283

    International Nuclear Information System (INIS)

    Carpenter, D.A.; Gao, N.; Xiao, Q.F.; Ponomarev, I.

    1996-01-01

    The purpose of this CRADA was to develop improved glass capillary, x-ray optics for analytical x-ray microbeam applications. X-Ray Optical Systems, Inc. (XOS) designed and fabricated capillary optics and LMES tested those optics for x-ray microanalytical applications using its unique X-Ray Microprobe. Tapered capillaries with 3-microm and 8-microm output openings were fabricated and tested. The tapered capillaries had better spectral quality for x-ray microfluorescence (XRMF) analysis, than non-tapered, straight capillaries that are currently used in the system. X-ray beam count-rates for the tapered capillaries were also greater than the straight capillaries. Two monolithic, polycapillary optics were fabricated and tested. The polycapillary optics produced focal spots of 40 and 100 microm. Beam intensities for the polycapillaries were, respective, 44 and 18 times the intensities found in straight 50-microm and 100-microm capillaries. High-sensitivity scanning will be possible because of the enhanced intensity of the polycapillary optic. LMES and the DP program will benefit from improved capabilities for nondestructive x-ray microanalysis, while XOS will benefit from test results that will enhance the marketability of their products

  6. Streaming experiment of gamma-ray obliquely incident on concrete shield wall with straight cylindrical ducts and verification of single scattering code

    International Nuclear Information System (INIS)

    Yamaji, Akio; Saito, Tetsuo.

    1988-01-01

    To investigate a proximity effect of ducts on shield performance against γ radiation, an experiment was performed at JRR-4 by entering the γ-ray beam into a concrete shield wall of 100 cm-thickness with 3 or 5 straight cylindrical ducts of radius of 4.45 cm placed in a straight line or crosswise at interval of 8.9 cm. The dose rates were measured using digital dosimeters on a horizontal line 20 cm apart from the rear of the wall with 0, 1, 3 and 5 ducts, and with the incident angles of 0deg, 7deg, 14deg and 20deg, respectively. The dose rate distributions depended on the number of ducts and the incident angle, and the dose rate ratios of with-three-ducts to no-duct distributed within 3.6∼12, 1.3∼5.0 and 1.1∼4.3, for the incident angles of 7deg, 14deg and 20deg, while those of with-single-duct to no-duct within 1.2∼7.1, 1.1∼2.7 and 1.0∼1.9, respectively. The experiment was analyzed using a multigroup single scattering code G33YSN able to deal with the geometry of the ducts exactly. For each incident angle, the calculation agreed with the experiment within a factor of 2. (author)

  7. Straightness measurement of large machine guideways

    Directory of Open Access Journals (Sweden)

    W. Ptaszyñski

    2011-10-01

    Full Text Available This paper shows the guideway types of large machines and describes problems with their straightness measurement. A short description of straightness measurement methods and the results of investigation in straightness of 10 meter long guideways of a CNC machine by means of the XL-10 Renishaw interferometer are also presented.

  8. Weighted straight skeletons in the plane.

    Science.gov (United States)

    Biedl, Therese; Held, Martin; Huber, Stefan; Kaaser, Dominik; Palfrader, Peter

    2015-02-01

    We investigate weighted straight skeletons from a geometric, graph-theoretical, and combinatorial point of view. We start with a thorough definition and shed light on some ambiguity issues in the procedural definition. We investigate the geometry, combinatorics, and topology of faces and the roof model, and we discuss in which cases a weighted straight skeleton is connected. Finally, we show that the weighted straight skeleton of even a simple polygon may be non-planar and may contain cycles, and we discuss under which restrictions on the weights and/or the input polygon the weighted straight skeleton still behaves similar to its unweighted counterpart. In particular, we obtain a non-procedural description and a linear-time construction algorithm for the straight skeleton of strictly convex polygons with arbitrary weights.

  9. Straight nearness spaces | Bentley | Quaestiones Mathematicae

    African Journals Online (AJOL)

    Straight spaces are spaces for which a continuous map defined on the space which is uniformly continuous on each set of a finite closed cover is then uniformly continuous on the whole space. Previously, straight spaces have been studied in the setting of metric spaces. In this paper, we present a study of straight spaces in ...

  10. The X-ray microscopy project at saga SLS

    International Nuclear Information System (INIS)

    Yasumoto, M.; Ishiguro, E.; Takemoto, K.; Kihara, H.; Kamijo, N.; Tomimasu, T.; Tsurushima, T.; Takahara, A.; Hara, K.; Chikaura, Y.

    2002-01-01

    A new high resolution X-ray microscopy project has been proposed at Saga synchrotron light source, which is a third generation synchrotron light facility in Japan. Two microscopy beamlines are planned for this project. One is a scanning microscope in the water window region, and the other is a full-field imaging microscope in the multi-keV X-ray energy region. To demonstrate the feasibility of the project, the optical layout of the scanning microscope was designed. The beamline mainly consists of a 3.5 cm periodical undulator, a varied line-spacing plane grating monochromator (600 lines/mm) and an end-station including a zone plate. Thus, the calculated X-ray properties focused on the sample position are as follows: the spot size is ∼ 70 nm, the monochromaticity is ∼2000, and the photon flux is 10 9 ∼ 10 10 photons/sec. (authors)

  11. Straight sinus thrombosis during neurosurgical operation.

    Science.gov (United States)

    Kawano, Hiroto; Nitta, Naoki; Nozaki, Kazuhiko

    2016-01-01

    Perioperative straight sinus thrombosis is extremely rare. A 59-year-old female was admitted to our department because of incidentally found small anterior cerebral artery (A1) aneurysm with microbleeding. After clipping the cerebral aneurysm, she had delayed emergence from anesthesia, total aphasia, and right hemiparesis. Fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI) of the head showed hyperintensity in the bilateral caudate nuclei, putamina, and thalami, and computed tomography of the head showed a hyperdense straight sinus, suggesting straight sinus thrombosis. Her neurologic symptoms improved gradually, and she achieved a full clinical recovery, with radiological evidence of recanalization of the straight sinus at follow-up. The possibility of straight sinus thrombosis should be considered in postoperative patients with unexplained postoperative deficits when MRI demonstrates hyperintensity in the bilateral basal ganglia and thalami on FLAIR signal images.

  12. Projection-type X-ray microscope based on a spherical compound refractive X-ray lens

    OpenAIRE

    Dudchik, Yu. I.; Gary, C. K.; Park, H.; Pantell, R. H.; Piestrup, M. A.

    2007-01-01

    New projection- type X-ray microscope with a compound refractive lens as the optical element is presented. The microscope consists of an X-ray source that is 1-2 mm in diameter, compound X-ray lens and X-ray camera that are placed in-line to satisfy the lens formula. The lens forms an image of the X-ray source at camera sensitive plate. An object is placed between the X-ray source and the lens as close as possible to the source, and the camera shows a shadow image of the object. Spatial resol...

  13. X-ray shadow projection microscopy of microwires

    International Nuclear Information System (INIS)

    Kasatkin, Yu.I.; Kasyuga, L.Z.; Kasyuga, P.I.; Kozyrev, A.S.; Khanonkin, A.A.

    1981-01-01

    The X-ray shadow projection microscopy as a method for testing geometrical parameters of microwires is considered. Two X-ray-optical circuits for measuring geometrical parameters of wires are described. It is shown that the coefficient of increase of the circuits does not depend on geometrical parameters of the wire under testing, and it is determined solely by the construction peculiarities of the circuits. The testability of geometric parameters of a wire, using DRON-2.0 X-ray diffractometer or its like, is discussed [ru

  14. 26 CFR 1.167(b)-1 - Straight line method.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Straight line method. 1.167(b)-1 Section 1.167(b... Straight line method. (a) In general. Under the straight line method the cost or other basis of the... may be reduced to a percentage or fraction. The straight line method may be used in determining a...

  15. 7 CFR 29.6128 - Straight Stripped (X Group).

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Straight Stripped (X Group). 29.6128 Section 29.6128... REGULATIONS TOBACCO INSPECTION Standards Grades § 29.6128 Straight Stripped (X Group). This group consists of..., and tolerances X1 Fine Quality Straight Stripped. Heavy, ripe, firm, semielastic, normal strength and...

  16. Generalized algorithm for X-ray projections generation in cone-beam tomography

    International Nuclear Information System (INIS)

    Qin Zhongyuan; Mu Xuanqin; Wang Ping; Cai Yuanlong; Hou Chuanjian

    2002-01-01

    In order to get rid of random factors in the measurement so as to support proceeding 3D reconstruction, a general approach is presented to obtain the X-ray projections in cone-beam tomography. The phantom is firstly discretized into cubic volume through inverse transformation then a generalized projection procedure is proposed to the digitized result without concerning what the phantom exactly is. In the second step, line integrals are calculated to obtain the projection of each X-ray through accumulation of tri-linear interpolation. Considering projection angles, a rotation matrix is proposed to the X-ray source and the detector plane so projections in arbitrary angles can be got. In this approach the algorithm is easy to be extended and irregular objects can also be processed. The algorithm is implemented in Visual C++ and experiments are done using different models. Satisfactory results are obtained. It makes good preparation for the proceeding reconstruction

  17. 14 CFR 417.215 - Straight-up time analysis.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Straight-up time analysis. 417.215 Section..., DEPARTMENT OF TRANSPORTATION LICENSING LAUNCH SAFETY Flight Safety Analysis § 417.215 Straight-up time analysis. A flight safety analysis must establish the straight-up time for a launch for use as a flight...

  18. Straight and White: Talking with My Mouth Full

    Science.gov (United States)

    Myers, W. Benjamin

    2008-01-01

    By using straight and white teeth as a metaphor for a straight and White identity, the author reflects on how this identity is performed, maintained, and often problematic. Using literature about identity performance, three different voices speak to and from straight and White identity. Using irony by blending arrogance and ignorance in the voice…

  19. Deposition of CsI aerosol in horizontal straight pipes in WIND project

    International Nuclear Information System (INIS)

    Sugimoto, J.; Maruyama, Y.; Igarashi, M.; Hidaka, A.; Maeda, A.; Harada, Y.; Hashimoto, K.

    1996-01-01

    In the WIND Project at Japan Atomic Energy Research Institute, the aerosol behaviors such as deposition, revaporization and resuspension have been investigated under the severe accident conditions. The present paper describes the deposition of CsI aerosol in horizontal straight pipes. The test results showed that the aerosol deposition depended on thermo-fluid dynamic characteristics of the carrier gas. In the test with the temperature gradient of the pipe, the deposition of CsI was remarkable within the downstream side, where the temperature of the gas was higher than that of the pipe wall. It is thus supposed that the major mechanism of the deposition was thermophoresis caused by the temperature gradient within the gas phase. However, circumferential distribution of the deposited CsI was influenced by the argon flow rate. In laminar flow case, larger amount of CsI was deposited on the ceiling than the floor area. Three-dimensional thermo-fluid dynamic analysis suggested that much sharper radial temperature gradient was developed within the gas near the ceiling area due to the formation of a natural convective secondary flow. This could result in the promotion of the thermophoretic aerosol deposition. On the other hand, slight circumferential distribution was observed in case of the high flow rate, probably due to a uniform temperature field. It was also found that the close coupling of the FP behavior and the detailed thermohydraulic analyses is essential in order to accurately predict the CsI deposition in the pipe. The findings on aerosol behaviors will also be utilized for the evaluation of sodium aerosol behaviors of fast reactors. (author)

  20. Assembling the LHC short straight sections

    CERN Document Server

    Maximilien Brice

    2005-01-01

    The building where the short straight sections are being assembled, was often called ‘Lego Land’ by the workers because of the wide variety of sets of magnets and cryostats. Short straight sections contain magnets for manipulating the beam inside cryostats with liquid helium to keep the magnets at a cool 1.9 K (-271.3°C).

  1. A Faster Algorithm for Computing Straight Skeletons

    KAUST Repository

    Cheng, Siu-Wing

    2014-09-01

    We present a new algorithm for computing the straight skeleton of a polygon. For a polygon with n vertices, among which r are reflex vertices, we give a deterministic algorithm that reduces the straight skeleton computation to a motorcycle graph computation in O(n (logn)logr) time. It improves on the previously best known algorithm for this reduction, which is randomized, and runs in expected O(n√h+1log2n) time for a polygon with h holes. Using known motorcycle graph algorithms, our result yields improved time bounds for computing straight skeletons. In particular, we can compute the straight skeleton of a non-degenerate polygon in O(n (logn) logr + r 4/3 + ε ) time for any ε > 0. On degenerate input, our time bound increases to O(n (logn) logr + r 17/11 + ε ).

  2. A Faster Algorithm for Computing Straight Skeletons

    KAUST Repository

    Mencel, Liam A.

    2014-05-06

    We present a new algorithm for computing the straight skeleton of a polygon. For a polygon with n vertices, among which r are reflex vertices, we give a deterministic algorithm that reduces the straight skeleton computation to a motorcycle graph computation in O(n (log n) log r) time. It improves on the previously best known algorithm for this reduction, which is randomised, and runs in expected O(n √(h+1) log² n) time for a polygon with h holes. Using known motorcycle graph algorithms, our result yields improved time bounds for computing straight skeletons. In particular, we can compute the straight skeleton of a non-degenerate polygon in O(n (log n) log r + r^(4/3 + ε)) time for any ε > 0. On degenerate input, our time bound increases to O(n (log n) log r + r^(17/11 + ε))

  3. A Faster Algorithm for Computing Straight Skeletons

    KAUST Repository

    Cheng, Siu-Wing; Mencel, Liam A.; Vigneron, Antoine E.

    2014-01-01

    We present a new algorithm for computing the straight skeleton of a polygon. For a polygon with n vertices, among which r are reflex vertices, we give a deterministic algorithm that reduces the straight skeleton computation to a motorcycle graph computation in O(n (logn)logr) time. It improves on the previously best known algorithm for this reduction, which is randomized, and runs in expected O(n√h+1log2n) time for a polygon with h holes. Using known motorcycle graph algorithms, our result yields improved time bounds for computing straight skeletons. In particular, we can compute the straight skeleton of a non-degenerate polygon in O(n (logn) logr + r 4/3 + ε ) time for any ε > 0. On degenerate input, our time bound increases to O(n (logn) logr + r 17/11 + ε ).

  4. A straightness error measurement method matched new generation GPS

    International Nuclear Information System (INIS)

    Zhang, X B; Lu, H; Jiang, X Q; Li, Z

    2005-01-01

    The axis of the non-diffracting beam produced by an axicon is very stable and can be adopted as the datum line to measure the spatial straightness error in continuous working distance, which may be short, medium or long. Though combining the non-diffracting beam datum-line with LVDT displace detector, a new straightness error measurement method is developed. Because the non-diffracting beam datum-line amends the straightness error gauged by LVDT, the straightness error is reliable and this method is matchs new generation GPS

  5. Colorado School of Mines Fusion Gamma Ray Project

    International Nuclear Information System (INIS)

    Cecil, F.E.

    1990-01-01

    This report summarizes the activities and accomplishments of the CSM Fusion Gamma Ray Project for the calendar year 1989. As reported in last year's Technical Progress Report, the initial objective of the project was the design and bench testing of an eight channel, very high count rate gamma ray spectrometer. The next objective of the project was the installation and field testing of a comparable fifteen channel spectrometer on TFTR. This objective has been accomplished over the past year and the system has been operated successfully at count rates approaching 10 MHz during neutral beam injected (NBI) deuterium plasmas with injected beam powers in excess of 20 MW. The MFE computer network link between CSM and TFTR has been most valuable in the accomplishment of the year's objectives and should serve as a model for future collaborations of outside researchers with experiments on TFTR and CIT. The coming year's work includes the spectrometry of high energy fusion gamma rays during 3 He minority ICRH heating of deuterium plasmas and hydrogen minority ICRH heating during Lithium pellet injection as diagnostics of energetic alpha particle production. We include in this report selected results from our parallel grant from the DOE Office of High Energy and Nuclear Physics as they pertain to the present APP grant. These results include experimentally derived thermonuclear reactivities of various light ion fusion plasmas for temperatures up to 40 keV. We would emphasize that our APP project is highly collaborative in nature and that Sid Medley and other members of the TFTR staff deserve much of the credit and bore much of the cost for many of the important accomplishments summarized in this report

  6. Morbidity Following Coloanal Anastomosis: A Comparison of Colonic J-Pouch vs Straight Anastomosis.

    Science.gov (United States)

    Brown, Shaun; Margolin, David A; Altom, Laura K; Green, Heather; Beck, David E; Kann, Brian R; Whitlow, Charles B; Vargas, Herschel David

    2018-02-01

    Low rectal tumors are often treated with sphincter-preserving resection followed by coloanal anastomosis. The purpose of this study was to compare the short-term complications following straight coloanal anastomosis vs colonic J-pouch anal anastomosis. Patients were identified who underwent proctectomy for rectal neoplasia followed by coloanal anastomosis in the 2008 to 2013 American College of Surgeons National Surgical Quality Improvement Program database. Demographic characteristics and 30-day postoperative complications were compared between groups. A national sample was extracted from the American College of Surgeons National Surgical Quality Improvement Project database. Inpatients following proctectomy and coloanal anastomosis for rectal cancer were selected. Demographic characteristics and 30-day postoperative complications were compared between the 2 groups. One thousand three hundred seventy patients were included, 624 in the straight anastomosis group and 746 in the colonic J-pouch group. Preoperative characteristics were similar between groups, with the exception of preoperative radiation therapy (straight anastomosis 35% vs colonic J-pouch 48%, p = 0.0004). Univariate analysis demonstrated that deep surgical site infection (3.7% vs 1.4%, p = 0.01), septic shock (2.25% vs 0.8%, p = 0.04), and return to the operating room (8.8% vs 5.0%, p = 0.0006) were more frequent in the straight anastomosis group vs the colonic J-pouch group. Major complications were also higher (23% vs 14%, p = 0.0001) and length of stay was longer in the straight anastomosis group vs the colonic J-pouch group (8.9 days vs 8.1 days, p = 0.02). After adjusting for covariates, major complications were less following colonic J-pouch vs straight anastomosis (OR, 0.57; CI, 0.38-0.84; p = 0.005). Subgroup analysis of patients who received preoperative radiation therapy demonstrated no difference in major complications between groups. This study had those limitations inherent to a

  7. 21 CFR 82.5 - General specifications for straight colors.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false General specifications for straight colors. 82.5... LISTING OF CERTIFIED PROVISIONALLY LISTED COLORS AND SPECIFICATIONS General Provisions § 82.5 General specifications for straight colors. No batch of a straight color listed in subpart B, C, or D shall be certified...

  8. Equilibrium depth of scour at straight guide banks

    Science.gov (United States)

    Gjunsburgs, B.; Bulankina, V.

    2017-10-01

    The equilibrium stage of scour at the head of straight guide banks with a uniform and stratified bed conditions have been studied. The contraction of the river by bridge crossing with straight guide banks considerably alters the flow pattern. The streamlines become curve and the concentration of streamlines, longitudinal and transverse slopes of the water surface, a local increase in velocity, vortex and eddy structures, and the origin of a flow separation zone between the extreme streamlines and the guide bank are observed and local scour is developing at the head of the straight guide banks. New formulae for calculation of equilibrium depth of scour at straight guide banks at uniform and stratified river bed is elaborated and confirmed by tests and computer modelling results.

  9. Reconstruction of tomographic image from x-ray projections of a few views

    International Nuclear Information System (INIS)

    Kobayashi, Fujio; Yamaguchi, Shoichiro

    1982-01-01

    Computer tomographs have progressed rapidly, and in the latest high performance types, the photographing time has been shortened to less than 5 sec, but the clear images of hearts have not yet been obtained. The X-ray tomographs used so far irradiate X-ray from many directions and measure the projected data, but by limiting projection direction to a small number, it was planned to shorter the X-ray photographing time and to reduce X-ray exposure as the objective of this study. In this paper, a method is proposed, by which tomographic images are reconstructed from projected data in a small number of direction by generalized inverse matrix penalty method. This method is the calculation method newly devised by the authors for this purpose. It is a kind of the nonlinear planning method added with the restrictive condition using a generalized inverse matrix, and it is characterized by the simple calculation procedure and rapid convergence. Moreover, the effect on reconstructed images when errors are included in projected data was examined. Also, the simple computer simulation to reconstruct tomographic images using the projected data in four directions was performed, and the usefulness of this method was confirmed. It contributes to the development of superhigh speed tomographs in future. (Kako, I.)

  10. Attitudes toward straight, gay male, and transsexual parenting.

    Science.gov (United States)

    Weiner, Brittany A; Zinner, Leah

    2015-01-01

    This study examined American attitudes toward transsexual and gay male parenting, compared to straight parenting. After reporting levels of transphobia, participants read a vignette regarding a couple seeking child adoption. Individuals high in transphobia perceived nontraditional couples as more emotionally unstable than straight couples and were less willing to grant custody of a child to the nontraditional couples vs. the straight couples. In addition, the transsexual couple faced more prejudice and discrimination than the gay male couple. Implications of these findings are discussed.

  11. Straight Talk for Good Health | NIH MedlinePlus the Magazine

    Science.gov (United States)

    ... of this page please turn Javascript on. Feature: Straight Talk for Good Health Straight Talk for Good Health Past Issues / Spring 2013 ... with your Doctor nihseniorhealth.gov/talkingwithyourdoctor/toc.html Straight talk with your healthcare provider is important. You ...

  12. New Upgrade Project for the Photon Factory Storage Ring

    International Nuclear Information System (INIS)

    Asaoka, S.; Haga, K.; Harada, K.; Honda, T.; Hori, Y.; Izawa, M.; Kasuga, T.; Kobayashi, M.; Kobayashi, Y.; Maezawa, H.; Minagawa, Y.; Mishina, A.; Mitsuhashi, T.; Miyajima, T.; Miyauchi, H.; Nagahashi, S.; Nogami, T.; Obina, T.; Pak, C. O.; Sakanaka, S.

    2004-01-01

    A new project for upgrading the 2.5-GeV Photon Factory (PF) storage ring is now being undertaken to create six new short-straight sections and to lengthen the existing eight straight sections. The short-straight sections will provide an opportunity to install short-period narrow-gap undulators, while the extensions of existing straight sections will be taken advantage of updating current insertion devices to the latest models in future. To this end, the lattice configuration around the straight sections is modified by replacing old quadrupole magnets with new shorter ones and placing them closer to the near-by bending magnets. Necessary replacement of the vacuum ducts and the beamline front ends will be carried out together. This project will be completed by the end of September, 2005, after six months of shutdown

  13. The Role of Project Science in the Chandra X-Ray Observatory

    Science.gov (United States)

    O'Dell, Stephen L.; Weisskopf, Martin C.

    2006-01-01

    The Chandra X-Ray Observatory, one of NASA's Great Observatories, has an outstanding record of scientific and technical success. This success results from the efforts of a team comprising NASA, its contractors, the Smithsonian Astrophysical Observatory, the instrument groups, and other elements of the scientific community, including thousands of scientists who utilize this powerful facility for astrophysical research. We discuss the role of NASA Project Science in the formulation, development, calibration, and operation of the Chandra X-ray Observatory. In addition to representing the scientific community within the Project, Project Science performed what we term "science systems engineering". This activity encompasses translation of science requirements into technical requirements and assessment of the scientific impact of programmatic and technical trades. We briefly describe several examples of science systems engineering conducted by Chandra Project Science.

  14. Coordinate reconstruction using box reconstruction and projection of X-ray photo

    International Nuclear Information System (INIS)

    Achmad Suntoro

    2011-01-01

    Some mathematical formula have been derived for a process of reconstruction to define the coordinate of any point relative to a pre set coordinate system. The process of reconstruction uses a reconstruction box in which each edge's length of the box is known, each top-bottom face and left-right face of the box having a cross marker, and the top face and the right face of the box as plane projections by X-ray source in perspective projection -system. Using the data of the two X-ray projection images, any point inside the reconstruction box, as long as its projection is recorded in the two photos, will be determined its coordinate relative to the midpoint of the reconstruction box as the central point coordinates. (author)

  15. Visual straight-ahead preference in saccadic eye movements.

    Science.gov (United States)

    Camors, Damien; Trotter, Yves; Pouget, Pierre; Gilardeau, Sophie; Durand, Jean-Baptiste

    2016-03-15

    Ocular saccades bringing the gaze toward the straight-ahead direction (centripetal) exhibit higher dynamics than those steering the gaze away (centrifugal). This is generally explained by oculomotor determinants: centripetal saccades are more efficient because they pull the eyes back toward their primary orbital position. However, visual determinants might also be invoked: elements located straight-ahead trigger saccades more efficiently because they receive a privileged visual processing. Here, we addressed this issue by using both pro- and anti-saccade tasks in order to dissociate the centripetal/centrifugal directions of the saccades, from the straight-ahead/eccentric locations of the visual elements triggering those saccades. Twenty participants underwent alternating blocks of pro- and anti-saccades during which eye movements were recorded binocularly at 1 kHz. The results confirm that centripetal saccades are always executed faster than centrifugal ones, irrespective of whether the visual elements have straight-ahead or eccentric locations. However, by contrast, saccades triggered by elements located straight-ahead are consistently initiated more rapidly than those evoked by eccentric elements, irrespective of their centripetal or centrifugal direction. Importantly, this double dissociation reveals that the higher dynamics of centripetal pro-saccades stem from both oculomotor and visual determinants, which act respectively on the execution and initiation of ocular saccades.

  16. Straight eye for the gay guy: composing queerness.

    Science.gov (United States)

    Alexander, Jonathan

    2010-01-01

    Drawing on the work of Didier Eribon and his theorization of the construction of gay male subjectivity, this article examines different "texts," broadly defined, that grapple specifically with straight men attempting to represent male homosexuality: Norman Mailer's essay, "The Homosexual Villain"; the Bravo reality television series Boy Meets Boy, and Michael Griffith's short story, "Hooper Gets a Perm." These texts represent attempts by straight authors to grapple with queer experience in ways that move the imagination of queers beyond simple stereotypes or uncritical explorations of the sexual "other." In the process of examining these texts, the following questions are addressed: What happens when a straight man attempts to represent a gay man? Does he "get it right," and is such a question even useful? More specifically, what is the value in having straights imagine queerness? Is such an imagining possible? Is such desirable? And, if so, what are the contours of such an imagining-as well as its possibilities and limitations, pedagogically, personally, and politically? Ultimately, I contend that the straight imagining of queerness offers rich potential for mutual understanding; furthermore, attempting to understand what goes into the making of those representations tells us much about how queerness circulates in our culture as a subject, a figure of discussion, contention, and representation.

  17. On Gamma Ray Instrument On-Board Data Processing Real-Time Computational Algorithm for Cosmic Ray Rejection

    Science.gov (United States)

    Kizhner, Semion; Hunter, Stanley D.; Hanu, Andrei R.; Sheets, Teresa B.

    2016-01-01

    Richard O. Duda and Peter E. Hart of Stanford Research Institute in [1] described the recurring problem in computer image processing as the detection of straight lines in digitized images. The problem is to detect the presence of groups of collinear or almost collinear figure points. It is clear that the problem can be solved to any desired degree of accuracy by testing the lines formed by all pairs of points. However, the computation required for n=NxM points image is approximately proportional to n2 or O(n2), becoming prohibitive for large images or when data processing cadence time is in milliseconds. Rosenfeld in [2] described an ingenious method due to Hough [3] for replacing the original problem of finding collinear points by a mathematically equivalent problem of finding concurrent lines. This method involves transforming each of the figure points into a straight line in a parameter space. Hough chose to use the familiar slope-intercept parameters, and thus his parameter space was the two-dimensional slope-intercept plane. A parallel Hough transform running on multi-core processors was elaborated in [4]. There are many other proposed methods of solving a similar problem, such as sampling-up-the-ramp algorithm (SUTR) [5] and algorithms involving artificial swarm intelligence techniques [6]. However, all state-of-the-art algorithms lack in real time performance. Namely, they are slow for large images that require performance cadence of a few dozens of milliseconds (50ms). This problem arises in spaceflight applications such as near real-time analysis of gamma ray measurements contaminated by overwhelming amount of traces of cosmic rays (CR). Future spaceflight instruments such as the Advanced Energetic Pair Telescope instrument (AdEPT) [7-9] for cosmos gamma ray survey employ large detector readout planes registering multitudes of cosmic ray interference events and sparse science gamma ray event traces' projections. The AdEPT science of interest is in the

  18. Recent trends of projection X-ray microscopy in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Yada, K. [Tohken CO., LTD. 2-27-7 Tamagawa Chofu, Tokyo 182-0025 (Japan)], E-mail: kyada@tohken.co.jp

    2009-08-15

    Recent activities of projection X-ray microscopy in Japan are reviewed. 1) By employing high brightness Schottky electron gun, resolution of 0.1 {mu}m is realized by Tohken CO. group and some application examples are shown. 2) Deblurring of Fresnel diffracted image formed by synchrotron orbital radiation (SOR) X-rays is successfully tried by Chiba University group. Remarkable Fresnel fringes appearing at HeLa cell are mostly reconstructed by an iteration method. 3) Element analysis is carried out by Meiji University group utilizing absorption-edge characteristics between two kinds of X-ray targets without X-ray spectrometer. Actually, Cu and Ni targets are used with an inter-changeable system for elemental analysis of Fe{sub 2}O{sub 3} particles and iron component in a mosquito larva.

  19. Uncertainty of spatial straightness in 3D measurement

    International Nuclear Information System (INIS)

    Wang Jinxing; Jiang Xiangqian; Ma Limin; Xu Zhengao; Li Zhu

    2005-01-01

    The least-square method is commonly employed to verify the spatial straightness in actual three-dimensional measurement process, but the uncertainty of the verification result is usually not given by the coordinate measuring machines. According to the basic principle of spatial straightness least-square verification and the uncertainty propagation formula given by ISO/TS 14253-2, a calculation method for the uncertainty of spatial straightness least-square verification is proposed in this paper. By this method, the coefficients of the line equation are regarded as a statistical vector, so that the line equation, the result of the spatial straightness verification and the uncertainty of the result can be obtained after the expected value and covariance matrix of the vector are determined. The method not only assures the integrity of the verification result, but also accords with the requirement of the new generation of GPS standards, which can improve the veracity of verification

  20. The Swift Supergiant Fast X-ray Transient Project

    Science.gov (United States)

    Romano, P.; Barthelmy, S.; Bozzo, E.; Burrows, D.; Ducci, L.; Esposito, P.; Evans, P.; Kennea, J.; Krimm, H.; Vercellone, S.

    2017-10-01

    We present the Swift Supergiant Fast X-ray Transients project, a systematic study of SFXTs and classical supergiant X-ray binaries (SGXBs) through efficient long-term monitoring of 17 sources including SFXTs and classical SGXBs across more than 4 orders of magnitude in X-ray luminosity on timescales from hundred seconds to years. We derived dynamic ranges, duty cycles, and luminosity distributions to highlight systematic differences that help discriminate between different theoretical models proposed to explain the differences between the wind accretion processes in SFXTs and classical SGXBs. Our follow-ups of the SFXT outbursts provide a steady advancement in the comprehension of the mechanisms triggering the high X-ray level emission of these sources. In particular, the observations of the outburst of the SFXT prototype IGR J17544-2619, when the source reached a peak X-ray luminosity of 3×10^{38} erg s^{-1}, challenged for the first time the maximum theoretical luminosity achievable by a wind-fed neutron star high mass X-ray binary. We propose that this giant outburst was due to the formation of a transient accretion disc around the compact object. We also created a catalogue of over 1000 BAT flares which we use to predict the observability and perspectives with future missions.

  1. The Theory and Assessment of Spatial Straightness Error Matched New Generation GPS

    International Nuclear Information System (INIS)

    Zhang, X B; Sheng, X L; Jiang, X Q; Li, Z

    2006-01-01

    In order to assess spatial straightness error matched new generation Dimensional Geometrical Product Specification and Verification (GPS), the theory of spatial straightness error assessing is proposed and its advantages are analyzed based on metrology and statistics in this paper. Then, the assessing parameter system is proposed and it is testified in real application comparing to assessment result of the geometric tolerance theory. Statistical parameters of this assessing system post the different characteristics of spatial straightness error, and can reveal the impact of spatial straightness error on the accessory function more roundly to complement the single assessing parameter of geometrical tolerance for straightness error. The statistical spatial straightness tolerance and statistical spatial straightness error proposed in this paper is possible to be applied in evaluation of other error of form, orientation, location and run-out

  2. A quasi-realtime x-ray microtomography system at the Advanced Photon Source

    International Nuclear Information System (INIS)

    DeCarlo, F.; Foster, I.; Insley, J.; Kesselman, C.; Lane, P.; Mancini, D.; McNulty, I.; Su, M.; Tieman, B.; Wang, Y.; Laszewski, G. von

    1999-01-01

    The combination of high-brilliance x-ray sources, fast detector systems, wide-bandwidth networks, and parallel computers can substantially reduce the time required to acquire, reconstruct, and visualize high-resolution three-dimensional tomographic datasets. A quasi-realtime computed x-ray microtomography system has been implemented at the 2-BM beamline at the Advanced Photon Source at Argonne National Laboratory. With this system, a complete tomographic data set can be collected in about 15 minutes. Immediately after each projection is obtained, it is rapidly transferred to the Mathematics and Computing Sciences Division where preprocessing and reconstruction calculations are performed concurrently with the data acquisition by a SGI parallel computer. The reconstruction results, once completed, are transferred to a visualization computer that performs the volume rendering calculations. Rendered images of the reconstructed data are available for viewing back at the beamline experiment station minutes after the data acquisition was complete. The fully pipelined data acquisition and reconstruction system also gives us the option to acquire the tomographic data set in several cycles, initially with coarse then with fine angular steps. At present the projections are acquired with a straight-ray projection imaging scheme using 5-20 keV hard x rays in either phase or amplitude contrast mode at a 1-10 pm resolution. In the future, we expect to increase the resolution of the projections to below 100 nm by using a focused x-ray beam at the 2-ID-B beamline and to reduce the combined acquisition and computation time to the 1 min scale with improvements in the detectors, network links, software pipeline, and computation algorithms

  3. Plastic anisotropy of straight and cross rolled molybdenum sheets

    International Nuclear Information System (INIS)

    Oertel, C.-G.; Huensche, I.; Skrotzki, W.; Knabl, W.; Lorich, A.; Resch, J.

    2008-01-01

    The microstructure, texture and mechanical properties of molybdenum sheets produced by different rolling processes were investigated by orientation imaging in the scanning electron microscope, X-ray diffraction and tensile tests, respectively. For comparable recrystallization degree of the sheets investigated, straight rolling with low reduction ratio produces α-fiber textures with a maximum at {100} . At higher rolling degrees the maximum shifts to {112} . Cross rolling increases the rotated cube component {100} . The strong differences in the texture measured are reflected in the plastic anisotropy characterized by differences in the yield stress and Lankford parameter which were measured along directions in the rolling plane at angles of 0 deg., 45 deg. and 90 deg. with the rolling direction. The Taylor-Bishop-Hill theory is used successfully to qualitatively explain the plastic anisotropy

  4. Duration of load behaviour of different sized straight timber beams subjected to bending in variable climate

    DEFF Research Database (Denmark)

    Hanhijärvi, A.; Galimard, P.; Hoffmeyer, Preben

    1998-01-01

    The paper is the second in a series which sums up the results of an extensive project to quantify the duration-of-load (DOL) effect on different sized timber beams in different climates. The paper deals with straight (unnotched) beams. The results of various DOL-tests of stepwise and constant...

  5. Radical heterosexuality: Straight teacher activism in schools : Does ally-led activism work?

    Directory of Open Access Journals (Sweden)

    Leigh Potvin

    2016-06-01

    Here, I explore the efficacy of straight teacher allies, the importance of understanding straight privilege, and the significance of radical heterosexuality for straight people doing LGBTQ activism. Relying on queer theory and decolonizing/Indigenous queer theory, I argue that it is necessary for straight teachers to acknowledge their straight privilege in order to challenge homophobia's companions: heterosexism and heteronormativity. In addressing the latter two covert forms of oppression in schools, teachers and students could shift into deeper, more effective resistance measures.

  6. Future projects of light kaonic atom X-ray spectroscopy

    International Nuclear Information System (INIS)

    Tatsuno, H.; Bazzi, M.; Beer, G.; Bellotti, G.; Berucci, C.; Bragadireanu, A.M.; Bosnar, D.; Cargnelli, M.; Curceanu, C.; Butt, A.D.; D’Uffizi, A.; Fiorini, C.; Ghio, F.; Guaraldo, C.; Hayano, R.S.; Iliescu, M.; Ishiwatari, T.; Iwasaki, M.; Sandri, P. Levi; Marton, J.; Okada, S.; Pietreanu, D.; Piscicchia, K.; Vidal, A. Romero; Sbardella, E.; Scordo, A.; Shi, H.; Sirghi, D.L.; Sirghi, F.; Doce, O. Vazquez; Widmann, E.; Zmeskal, J.

    2016-01-01

    X-ray spectroscopy of light kaonic atoms is a unique tool to provide precise information on the fundamental K̄N interaction at the low-energy limit and the in-medium nuclear interaction of K"−. The future experiments of kaonic deuterium strong-interaction shift and width (SIDDHARTA-2 and J-PARC E57) can extract the isospin dependent K"−N interaction at threshold. The high-resolution X-ray spectroscopy of kaonic helium with microcalorimeters (J-PARC E62) has the possibility to solve the long-standing potential-strength problem of the attractive K"−-nucleus interaction. Here, the recent experimental results and the future projects of X-ray spectroscopy of light kaonic atoms are presented.

  7. Bent versus straight tips in micropulsed longitudinal phacoemulsification.

    Science.gov (United States)

    Stagg, Brian C; Gupta, Isha; Cahoon, Judd; Ronquillo, Cecinio; Shi, Dallas; Zaugg, Brian; Gardiner, Gareth; Barlow, William R; Pettey, Jeff H; Aabid Farukhi, M; Jensen, Jason; Olson, Randall J

    2015-10-01

    The aim of this study was to evaluate bent and straight phacoemulsification tips to determine which tip is more efficient in removal of lens fragments, using micropulsed longitudinal ultrasound in phacoemulsification. In vitro laboratory study. The John A. Moran Eye Center Laboratories, University of Utah, Salt Lake City, Utah, was the study setting. Pig lenses hardened in a manner comparable with dense human cataracts were cut into 2-mm cubes and removed with micropulsed longitudinal ultrasound using settings previously shown to be optimally efficient (6 milliseconds on and 6 milliseconds off for a bent tip). To verify this time as most efficient for a straight tip, we also tested times of 5, 6, and 7 milliseconds time on and off. The tips were either straight or with a 20-degree bend. Twenty cubes were used for each comparative run. For the straight tip, 6 milliseconds on (1.56 ± 0.815 seconds) was significantly more efficient than 7 milliseconds on (2.45 ± 1.56 seconds, p = 0.001) and not significantly more efficient than 5 milliseconds on (1.69 ± 0.86 seconds, p = 0.43). Five milliseconds off time (1.45 ± 0.76s) was more efficient than 6 milliseconds (2.06 ± 1.37 seconds, p = 0.004) and 7 milliseconds off (2.18 ± 1.24s, p = 0.001). The straight tip was more efficient than the bent tip (1.38 ± 0.83 versus 2.93 ± 2.14 seconds, p = 0.006). Results are contrary to accepted common belief. Micropulsed longitudinal phacoemulsification is more efficient with a straight rather than a bent tip. Copyright © 2015 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  8. Straight line closure of congenital macrostomia

    Directory of Open Access Journals (Sweden)

    Schwarz Richard

    2004-01-01

    Full Text Available The results of patients operated on by Nepal Cleft Lip and Palate Association (NECLAPA surgeons for congenital macrostomia were prospectively studied between January 2000 and December 2002. There were four males and three females with a median age of 10 years. Three had an associated branchial arch syndrome. In all patients an overlapping repair of orbicularis oris was done. Six patients had a straight line closure with excellent cosmetic results and one a Z-plasty with a more obvious scar. All had a normal appearing commissure. Overlapping orbicularis repair with straight line skin closure for this rare congenital anomaly is recommended.

  9. Project of a photoelectron X-ray microscope on ACO storage ring

    International Nuclear Information System (INIS)

    Polack, F.; Lowenthal, S.

    1983-01-01

    A photoelectron X-ray microscope is described which is based on the principles of contact X-ray imaging and of image converters. An X-ray image is projected by a parallel X-ray beam on a thin transmission photocathode. The emitted electrons are accelerated and imaged at large magnification by an emission microscope. The instrument, which is presently under construction, is designed to provide high resolution. An electron velocity filter has been added to the usual cross-over aperture so as to reduce the spherochromatic aberration, and the cathode lens has been designed to reduce field curvature. Resolution and detection efficiency of Au and CsI cathodes are compared. The interest of the instrument for soft X-ray microscopy is briefly discussed. (orig.)

  10. Highly sensitive straightness measurement system using a ball-lens

    International Nuclear Information System (INIS)

    Lee, Minho; Yang, Hyun-Ik; Cho, Nahm-Gyoo

    2016-01-01

    In this paper, a new and simple optical technique to accurately measure the straightness errors of a linear stage is proposed. To improve the performance, including the measurement sensitivity and resolution of the measurement system, and to simultaneously measure two-dimensional straightness errors (2D straightness errors), an optical system was designed using a laser, a retro-reflector, a ball-lens, and a two-dimensional position sensitive detector (2D PSD). The characteristics of the measurement system were analytically and experimentally investigated. A prototype measurement system was manufactured based on the investigated results, and the performances of this system have been tested. The measuring performance of the system was easily improved by about 12 times using the proposed technique and it can be further improved. It is shown that the proposed technique can easily and effectively improve the performance of a conventional straightness measurement system based on the geometric optical method using a PSD. (paper)

  11. Ratcheting failure of pressurised straight pipes and elbows under reversed bending

    International Nuclear Information System (INIS)

    Vishnuvardhan, S.; Raghava, G.; Gandhi, P.; Saravanan, M.; Goyal, Sumit; Arora, Punit; Gupta, Suneel K.; Bhasin, Vivek

    2013-01-01

    Ratcheting studies were carried out on Type 304LN stainless steel straight pipes and elbows subjected to steady internal pressure and cyclic bending load. The internal pressure for all the straight pipes was 35 MPa and in the case of elbows the internal pressure was varied for different elbows, ranging from 27.6 MPa to 39.2 MPa. Cyclic bending load was applied on the specimens by subjecting them to different levels of load-line displacement. The specimens have undergone significant ratchet swelling (ballooning), ovalization and consequent thinning of the cross-section during ratcheting. The straight pipes failed either by occurrence of through-wall crack accompanied by simultaneous ballooning, or bursting with simultaneous ballooning. All the elbows failed by occurrence of through-wall crack accompanied by simultaneous ballooning. Ratcheting behaviour of straight pipes and elbows were compared and it was generally inferred that ratcheting was more pronounced in straight pipes than in elbows. -- Graphical abstract: Strain history for the specimen QCE-RAT-6-L1. Highlights: • Studies were carried out under combined internal pressure and cyclic bending. • Ratcheting strains were measured at critical locations of the specimens. • Quantified the percentage of ballooning, ovalization and reduction in thickness. • Modes of ratcheting failure of straight pipes and elbows are studied. • Inferred that ratcheting is more pronounced in straight pipes than in elbows

  12. Gamma-ray CT from incomplete projections for two-phase pipe flow.

    Science.gov (United States)

    Xin, S; Wang, H X

    2017-02-01

    A low-energy low-dose γ-ray computed tomography (CT) system used in the gas-liquid two-phase pipe flow measurement has been studied at Tianjin University in recent years. The γ-ray CT system, having a third-generation X-ray CT scanning configuration, is comprised of one 300mCi 241 Am source and 17 CdZnTe detector units and achieves a spatial image resolution of about 7 mm. It is primarily intended to measure the two-phase pipe flow and provide improvement suggestions for industrial CT system. Recently we improve the design for image reconstruction from incomplete projection to optimize the scanning parameters and reduce the radiation dose. First, tomographic problem from incomplete projections is briefly described. Next, a system structure and a hardware circuit design are listed and explained, especially on time parameter setting of the pulse shaper. And then a detailed system analysis is provided in Section II, mainly focusing on spatial resolution, temporal resolution, system noise, and imaging algorithm. Finally, we carry on necessary static and dynamic experiments in a full scan (360°) and two sets of partial scan reconstruction tests to determine the feasibility of this γ-ray CT system for reconstructing the images from insufficient projections. And based on an A-variable algebraic reconstruction technique method, a specially designed algorithm, we evaluate the system performance and noise level of this CT system working quantitatively and qualitatively. Results of dynamic test indicate that the acceptable results can be acquired using a multi-source γ-ray CT system with the same parameters when the flow rate is less than 0.04 m/s and the imaging speed is slower than 33 frames/s.

  13. Diffraction at a Straight Edge

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 20; Issue 5. Diffraction at a Straight Edge: A Gem from Sommerfeld's Work in Classical Physics. Rajaram Nityananda. General Article Volume 20 Issue 5 May 2015 pp 389-400 ...

  14. The MU-RAY project: Volcano radiography with cosmic-ray muons

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosi, G. [INFN sezione di Perugia (Italy); Ambrosino, F. [INFN sezione di Napoli (Italy); Universita Federico II, Napoli (Italy); Battiston, R. [INFN sezione di Perugia (Italy); Universita di Perugia (Italy); Bross, A. [Fermilab (United States); Callier, S. [LAL, Orsay (France); Cassese, F. [INFN sezione di Napoli (Italy); Castellini, G. [CNR-IFAC, Firenze (Italy); Ciaranfi, R. [INFN sezione Firenze (Italy); Cozzolino, F. [INFN sezione di Napoli (Italy); D' Alessandro, R. [INFN sezione Firenze (Italy); Universita di Firenze (Italy); La Taille, C. de [LAL, Orsay (France); Iacobucci, G. [INFN sezione di Napoli (Italy); Marotta, A. [INFN sezione di Napoli (Italy); Universita Federico II, Napoli (Italy); Masone, V. [INFN sezione di Napoli (Italy); Martini, M. [INGV-Osservatorio Vesuviano, Napoli (Italy); Nishiyama, R. [Earthquake Research Institute, The University of Tokyo (Japan); Noli, P. [INFN sezione di Napoli (Italy); Universita Federico II, Napoli (Italy); Orazi, M. [INGV-Osservatorio Vesuviano, Napoli (Italy); Parascandolo, L.; Parascandolo, P. [INFN sezione di Napoli (Italy)

    2011-02-01

    Cosmic-ray muon radiography is a technique for imaging the variation of density inside the top few 100 m of a volcanic cone. With resolutions up to 10s of meters in optimal detection conditions, muon radiography can provide images of the top region of a volcano edifice with a resolution that is considerably better than that typically achieved with conventional methods. Such precise measurements are expected to provide us with information on anomalies in the rock density distribution, like those expected from dense lava conduits, low density magma supply paths or the compression with depth of the overlying soil. The MU-RAY project aims at the construction of muon telescopes and the development of new analysis tools for muon radiography. The telescopes are required to be able to work in harsh environment and to have low power consumption, good angular and time resolutions, large active area and modularity. The telescope consists of two X-Y planes of 2x2 square meters area made by plastic scintillator strips of triangular shape. Each strip is read by a fast WLS fiber coupled to a silicon photomultiplier. The readout electronics is based on the SPIROC chip.

  15. 49 CFR Appendix A to Part 1035 - Uniform Straight Bill of Lading

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 8 2010-10-01 2010-10-01 false Uniform Straight Bill of Lading A Appendix A to Part 1035 Transportation Other Regulations Relating to Transportation (Continued) SURFACE... Appendix A to Part 1035—Uniform Straight Bill of Lading Uniform Straight Bill of Lading Original—Not...

  16. Setting the Record Straight. The Truth About Fad Diets.

    Science.gov (United States)

    Wheat Foods Council, Parker, CO.

    The Setting the Record Straight information packet presents facts to set the record straight about nutrition and debunk fad diets. The kit features materials designed to communicate the importance of balanced eating. Materials include: a time line of fad diets; four reproducible fad diet book review handouts that show the misleading claims rampant…

  17. Preferences of AP position of the straight Caucasian facial profile.

    Science.gov (United States)

    Mees, Steven; Jiménez Bellinga, Raúl; Mommaerts, Maurice Y; De Pauw, Guy A M

    2013-12-01

    Several investigators have compared the perception of profile attractiveness between professional and non-professional people, different groups of clinicians, and different ethnic groups. Our aim was to study preferences for facial protrusion in the lateral view for a straight Class I profile and to study the influence of gender, age, sex preference, and profession. Portrait images of one male and one female model with a Class I occlusal relationship were warped into nine different antero-posterior positions. An internet site was established to reach as many people as possible, and a request was sent by email to participate in a scientific experiment. Finally, 1707 Caucasion assessors could be grouped. The preferred male profile is the straight full ante profile. For a feminine facial profile, the straight average and the straight 2/3 ante profiles were perceived as the most attractive. Surgeons tended to give significantly higher scores to attractive (ante) profiles, which correlated strongly with scores of the orthodontists. Whenever possible with combined orthodontic/surgery treatment, straight ante profiles should be aimed for. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  18. Conceptual Design of ILC Damping Ring Wiggler Straight Vacuum System

    International Nuclear Information System (INIS)

    Marks, S.; Kennedy, K.; Plate, D.; Schlueter, R.D.; Zisman, M.

    2007-01-01

    The positron and electron damping rings for the International Linear Collider will contain long straight sections consisting of twenty wiggler/quadrupole pairs. The wigglers will be based upon the CESR superconducting design. There are a number of challenges associated with the design of the wiggler straight vacuum system, in particular, the absorption of photon power generated by the wigglers. This paper will present the overall conceptual design of the wiggler straight vacuum system developed for the ILC Reference Design Report. Particular emphasis will be placed on photon power load calculations and the absorber design

  19. Large-area soft x-ray projection lithography using multilayer mirrors structured by RIE

    Science.gov (United States)

    Rahn, Steffen; Kloidt, Andreas; Kleineberg, Ulf; Schmiedeskamp, Bernt; Kadel, Klaus; Schomburg, Werner K.; Hormes, F. J.; Heinzmann, Ulrich

    1993-01-01

    SXPL (soft X-ray projection lithography) is one of the most promising applications of X-ray reflecting optics using multilayer mirrors. Within our collaboration, such multilayer mirrors were fabricated, characterized, laterally structured and then used as reflection masks in a projecting lithography procedure. Mo/Si-multilayer mirrors were produced by electron beam evaporation in UHV under thermal treatment with an in-situ X-ray controlled thickness in the region of 2d equals 14 nm. The reflectivities measured at normal incidence reached up to 54%. Various surface analysis techniques have been applied in order to characterize and optimize the X-ray mirrors. The multilayers were patterned by reactive ion etching (RIE) with CF(subscript 4), using a photoresist as the etch mask, thus producing X-ray reflection masks. The masks were tested in the synchrotron radiation laboratory of the electron accelerator ELSA at the Physikalisches Institut of Bonn University. A double crystal X-ray monochromator was modified so as to allow about 0.5 cm(superscript 2) of the reflection mask to be illuminated by white synchrotron radiation. The reflected patterns were projected (with an energy of 100 eV) onto the resist (Hoechst AZ PF 514), which was mounted at an average distance of about 7 mm. In the first test-experiments, structure sizes down to 8 micrometers were nicely reproduced over the whole of the exposed area. Smaller structures were distorted by Fresnel-diffraction. The theoretically calculated diffraction images agree very well with the observed images.

  20. Facile Synthesis of Long, Straight and Uniform Copper Nanowires via a Solvothermal Method

    Institute of Scientific and Technical Information of China (English)

    Chunfu Lin; Hong Lin; Ning Wang; Xing Zhang; Jun Yang; Jianbo Li; Xiaozhan Yang

    2006-01-01

    Copper nanowires were facilely prepared via a solvothermal method. In this method, cetyltrimethylammonium bromide (CTAB) was used as a soft template, copper nitrate was an inorganic precursor, and absolute ethanol served as a reducing agent as well as a solvent. X-ray diffraction (XRD) and scanning electron microscopy (SEM) were used to characterize the as-prepared copper nanowires. The as-prepared copper nanowires are fairly uniform and long. The majority of them are longer than 100 μm and some even longer than 200 μm. Furthermore, most nanowires are quite straight. In addition,The mechanism of the growth process of copper nanowires was discussed.

  1. A project of X-ray hardening correction in large ICT

    International Nuclear Information System (INIS)

    Fang Min; Liu Yinong; Ni Jianping

    2005-01-01

    This paper presents a means of polychromatic X-ray beam hardening correction using a standard function to transform the polychromatic projection to monochromatic projection in large Industrial Computed Tomography (ICT). Some parameters were defined to verify the validity of hardening correction in large ICT and optimized. Simulated experiments were used to prove that without prior knowledge of the composition of the scanned object, the correction method using monochromatic reconstruction arithmetic could remove beam hardening artifact greatly. (authors)

  2. Soft-X-Ray Projection Lithography Using a High-Repetition-Rate Laser-Induced X-Ray Source for Sub-100 Nanometer Lithography Processes

    NARCIS (Netherlands)

    E. Louis,; F. Bijkerk,; Shmaenok, L.; Voorma, H. J.; van der Wiel, M. J.; Schlatmann, R.; Verhoeven, J.; van der Drift, E. W. J. M.; Romijn, J.; Rousseeuw, B. A. C.; Voss, F.; Desor, R.; Nikolaus, B.

    1993-01-01

    In this paper we present the status of a joint development programme on soft x-ray projection lithography (SXPL) integrating work on high brightness laser plasma sources. fabrication of multilayer x-ray mirrors. and patterning of reflection masks. We are in the process of optimization of a

  3. SPS, preassembly of short straight sections

    CERN Multimedia

    1975-01-01

    Short straight sections were preassembled with their vacuum chambers, ready for installation in the SPS. Here we see two, containing sextupoles for chromaticity adjustment. See also 7501017, 7501018, and Annual Report 1976, p.174.

  4. SPS, short straight section with sextupole

    CERN Multimedia

    CERN PhotoLab

    1975-01-01

    Short straight sections were preassembled with their vacuum chambers, ready for installation in the SPS. This one contains a sextupole for chromaticity adjustment. See also 7501017, 7501009X, and Annual Report 1974, p.174.

  5. Stigma and Stigma by Association in Perceptions of Straight Allies

    Science.gov (United States)

    Goldstein, Susan B.

    2017-01-01

    As evidence builds for straight allies' contributions to battling sexual prejudice, barriers to assuming this role must be identified and dismantled. This study investigated stigma and stigma by association in perceptions of straight allies in a college population. Adjective rating items were completed by 505 participants who identified as…

  6. Spider diffraction: a comparison of curved and straight legs

    International Nuclear Information System (INIS)

    Richter, J.L.

    1984-01-01

    It has been known for some time that, if curved legs rather than the usual straight ones are used in the spider that supports the secondary optics in certain telescopes, the visible diffraction effect is reduced. Fraunhofer theory is used to calculate the diffraction effects due to the curved leg spider. Calculated and photographic diffraction patterns are compared for straight and curved leg spiders

  7. Diagnosing and mapping pulmonary emphysema on X-ray projection images: incremental value of grating-based X-ray dark-field imaging.

    Science.gov (United States)

    Meinel, Felix G; Schwab, Felix; Schleede, Simone; Bech, Martin; Herzen, Julia; Achterhold, Klaus; Auweter, Sigrid; Bamberg, Fabian; Yildirim, Ali Ö; Bohla, Alexander; Eickelberg, Oliver; Loewen, Rod; Gifford, Martin; Ruth, Ronald; Reiser, Maximilian F; Pfeiffer, Franz; Nikolaou, Konstantin

    2013-01-01

    To assess whether grating-based X-ray dark-field imaging can increase the sensitivity of X-ray projection images in the diagnosis of pulmonary emphysema and allow for a more accurate assessment of emphysema distribution. Lungs from three mice with pulmonary emphysema and three healthy mice were imaged ex vivo using a laser-driven compact synchrotron X-ray source. Median signal intensities of transmission (T), dark-field (V) and a combined parameter (normalized scatter) were compared between emphysema and control group. To determine the diagnostic value of each parameter in differentiating between healthy and emphysematous lung tissue, a receiver-operating-characteristic (ROC) curve analysis was performed both on a per-pixel and a per-individual basis. Parametric maps of emphysema distribution were generated using transmission, dark-field and normalized scatter signal and correlated with histopathology. Transmission values relative to water were higher for emphysematous lungs than for control lungs (1.11 vs. 1.06, pemphysema provides color-coded parametric maps, which show the best correlation with histopathology. In a murine model, the complementary information provided by X-ray transmission and dark-field images adds incremental diagnostic value in detecting pulmonary emphysema and visualizing its regional distribution as compared to conventional X-ray projections.

  8. Direction-Sensitive Hand-Held Gamma-Ray Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mukhopadhyay, S.

    2012-10-04

    A novel, light-weight, hand-held gamma-ray detector with directional sensitivity is being designed. The detector uses a set of multiple rings around two cylindrical surfaces, which provides precise location of two interaction points on two concentric cylindrical planes, wherefrom the source location can be traced back by back projection and/or Compton imaging technique. The detectors are 2.0 × 2.0 mm europium-doped strontium iodide (SrI2:Eu2+) crystals, whose light output has been measured to exceed 120,000 photons/MeV, making it one of the brightest scintillators in existence. The crystal’s energy resolution, less than 3% at 662 keV, is also excellent, and the response is highly linear over a wide range of gamma-ray energies. The emission of SrI2:Eu2+ is well matched to both photo-multiplier tubes and blue-enhanced silicon photodiodes. The solid-state photomultipliers used in this design (each 2.0 × 2.0 mm) are arrays of active pixel sensors (avalanche photodiodes driven beyond their breakdown voltage in reverse bias); each pixel acts as a binary photon detector, and their summed output is an analog representation of the total photon energy, while the individual pixel accurately defines the point of interaction. A simple back-projection algorithm involving cone-surface mapping is being modeled. The back projection for an event cone is a conical surface defining the possible location of the source. The cone axis is the straight line passing through the first and second interaction points.

  9. Production of short straight sections hits 100 units

    CERN Multimedia

    2005-01-01

    The 100th short straight section for the Large Hadron Collider was assembled at CERN at the beginning of April. These units combine superconducting quadrupoles and other multipole corrector magnets, housed in their cryostats, which are used to guide, focus and fine-tune the beam in the LHC. Building 904, where the 474 short straight sections are being assembled, is often called "Lego Land" by the workers, with a touch of humor and pride because of the wide variety of these sets of magnets and cryostats .

  10. 26 CFR 1.9001 - Statutory provisions; Retirement-Straight Line Adjustment Act of 1958.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 13 2010-04-01 2010-04-01 false Statutory provisions; Retirement-Straight Line... provisions; Retirement-Straight Line Adjustment Act of 1958. Section 94 of the Technical Amendments Act of 1958 (72 Stat. 1669) provides as follows: Sec. 94. Change from retirement to straight line method of...

  11. Low Horizontal Beta Function In Long Straights Of The NSLS-II Lattice

    International Nuclear Information System (INIS)

    Fanglei, L.; Bengtsson, J.; Guo, W.; Krinsky, S.; Li, Y.; Yang, L.

    2011-01-01

    The NSLS-II storage ring lattice is comprised of 30 DBA cells arranged in 15 superperiods. There are 15 long straight sections (9.3m) for injection, RF and insertion devices and 15 short straights (6.6m) for insertion devices. In the baseline lattice, the short straights have small horizontal and vertical beta functions but the long straights have large horizontal beta function optimized for injection. In this paper, we explore the possibility of maintaining three long straights with large horizontal beta function while providing the other 12 long straights with smaller horizontal beta function to optimize the brightness of insertion devices. Our study considers the possible linear lattice solutions as well as characterizing the nonlinear dynamics. Results are reported on optimization of dynamic aperture required for good injection efficiency and adequate Touschek lifetime. This paper discusses dynamic aperture optimization for the NSLS-II lattice with alternate high and low horizontal beta function in the long straights, which is proposed for the optimization of the brightness of insertion devices. The linear optics is optimized to meet the requirements of lattice function and source properties. Nonlinear optimization for a lattice with working point at (37.18, 16.2) is performed. Considering the realistic magnets errors and physical apertures, we calculate the frequency maps and plot the tune footprint. The results show that the lattice with high-low beta function has adequate dynamic aperture for good injection efficiency and sufficient Touschek lifetime.

  12. Digital x-ray tomosynthesis with interpolated projection data for thin slab objects

    Science.gov (United States)

    Ha, S.; Yun, J.; Kim, H. K.

    2017-11-01

    In relation with a thin slab-object inspection, we propose a digital tomosynthesis reconstruction with fewer numbers of measured projections in combinations with additional virtual projections, which are produced by interpolating the measured projections. Hence we can reconstruct tomographic images with less few-view artifacts. The projection interpolation assumes that variations in cone-beam ray path-lengths through an object are negligible and the object is rigid. The interpolation is performed in the projection-space domain. Pixel values in the interpolated projection are the weighted sum of pixel values of the measured projections considering their projection angles. The experimental simulation shows that the proposed method can enhance the contrast-to-noise performance in reconstructed images while sacrificing the spatial resolving power.

  13. 21 CFR 70.20 - Packaging requirements for straight colors (other than hair dyes).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Packaging requirements for straight colors (other than hair dyes). 70.20 Section 70.20 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH... straight colors (other than hair dyes). Straight colors shall be packaged in containers which prevent...

  14. Seven years with the Swift Supergiant Fast X-ray Transients project

    Science.gov (United States)

    Romano, P.

    2015-09-01

    Supergiant Fast X-ray Transients (SFXTs) are HMXBs with OB supergiant companions. I review the results of the Swift SFXT project, which since 2007 has been exploiting Swift's capabilities in a systematic study of SFXTs and supergiant X-ray binaries (SGXBs) by combining follow-ups of outbursts, when detailed broad-band spectroscopy is possible, with long-term monitoring campaigns, when the out-of-outburst fainter states can be observed. This strategy has led us to measure their duty cycles as a function of luminosity, to extract their differential luminosity distributions in the soft X-ray domain, and to compare, with unprecedented detail, the X-ray variability in these different classes of sources. I also discuss the ;seventh year crisis;, the challenges that the recent Swift observations are making to the prevailing models attempting to explain the SFXT behavior.

  15. Body image in gay and straight men: a qualitative study.

    Science.gov (United States)

    Morgan, John F; Arcelus, Jon

    2009-11-01

    Recent research has emphasized vulnerability to eating disorders in gay men, with calls for research on causality, cultural factors and focus on a younger age cohort. This study aimed to examine body image and related eating behaviours in younger gay and straight men. Qualitative study using a sample of gay and straight male university students, applying audiotaped and transcribed depth interview subjected to interpretative phenomenological analysis. Fifteen young men (18-24) with a spectrum of sexual orientation (gay, straight and bisexual) agreed to participate. Five dominant categories emerged: body image ideal, external influences, perception of body image, dieting, mechanisms for modification (diet, exercise, cosmetics) and sexual orientation. Health and aesthetic ideals appear less divorced for young men than women, offering some degree of protection from eating disorders. Nonetheless there is widespread body dissatisfaction. Media and social influences are powerful, particularly for single gay men, but the study suggests fewer differences than similarities between gay and straight men. Copyright (c) 2009 John Wiley & Sons, Ltd and Eating Disorders Association.

  16. A laser interferometer for measuring straightness and its position based on heterodyne interferometry

    International Nuclear Information System (INIS)

    Chen Benyong; Zhang Enzheng; Yan Liping; Li Chaorong; Tang Wuhua; Feng Qibo

    2009-01-01

    Not only the magnitude but also the position of straightness errors are of concern to users. However, current laser interferometers used for measuring straightness seldom give the relative position of the straightness error. To solve this problem, a laser interferometer for measuring straightness and its position based on heterodyne interferometry is proposed. The optical configuration of the interferometer is designed and the measurement principle is analyzed theoretically. Two experiments were carried out. The first experiment verifies the validity and repeatability of the interferometer by measuring a linear stage. Also, the second one for measuring a flexure-hinge stage demonstrates that the interferometer is capable of nanometer measurement accuracy. These results show that this interferometer has advantages of simultaneously measuring straightness error and the relative position with high precision, and a compact structure.

  17. Fluorescence detection of white-beam X-ray absorption anisotropy: towards element-sensitive projections of local atomic structure

    International Nuclear Information System (INIS)

    Korecki, P.; Tolkiehn, M.; Dąbrowski, K. M.; Novikov, D. V.

    2011-01-01

    A method for a direct measurement of X-ray projections of the atomic structure is described. Projections of the atomic structure around Nb atoms in a LiNbO 3 single crystal were obtained from a white-beam X-ray absorption anisotropy pattern detected using Nb K fluorescence. Projections of the atomic structure around Nb atoms in a LiNbO 3 single crystal were obtained from a white-beam X-ray absorption anisotropy (XAA) pattern detected using Nb K fluorescence. This kind of anisotropy results from the interference of X-rays inside a sample and, owing to the short coherence length of a white beam, is visible only at small angles around interatomic directions. Consequently, the main features of the recorded XAA corresponded to distorted real-space projections of dense-packed atomic planes and atomic rows. A quantitative analysis of XAA was carried out using a wavelet transform and allowed well resolved projections of Nb atoms to be obtained up to distances of 10 Å. The signal of nearest O atoms was detected indirectly by a comparison with model calculations. The measurement of white-beam XAA using characteristic radiation indicates the possibility of obtaining element-sensitive projections of the local atomic structure in more complex samples

  18. Additional Quadrupoles At Center Of Long Straights In The NSLS-II Lattice

    International Nuclear Information System (INIS)

    Lin, F.; Bengtsson, J.; Guo, W.; Krinsky, S.; Li, Y.; Yang, L.

    2011-01-01

    The NSLS-II storage ring lattice is comprised of 30 DBA cells arranged in 15 superperiods. There are 15 long straight sections (9.3m) for injection, RF and insertion devices and 15 shorter straights (6.6m) for insertion devices. In the baseline lattice, the short straights have small horizontal and vertical beta functions but the long straights have large horizontal beta function optimized for injection. In this paper, we explore the possibility of installing additional quadrupoles at the center of selected long straight sections in order to provide two low-beta source locations for undulators in the same straight. The required modification to the linear lattice is discussed as well as the preservation of adequate dynamic aperture required for good injection efficiency and adequate Touschek lifetime. This paper discusses the possibility of producing two low-beta source locations for optimum brightness of undulators in the long straights of NSLS-II lattice by installing additional quadrupoles at the center. The linear optics is optimized to satisfy the requirements of lattice function and properties. Nonlinear optimization for a lattice with working point at (37.16, 17.22) is performed. Considering the magnets misalignment errors and physical apertures, we calculate the frequency maps and plot the tune footprint. The results show that the modified high-low beta function lattice can achieve a modest dynamic aperture in this preliminary study. Further work will continue to expand the dynamic aperture to meet the requirement of good injection efficiency and sufficient Touschek lifetime.

  19. A New Pose Estimation Algorithm Using a Perspective-Ray-Based Scaled Orthographic Projection with Iteration.

    Directory of Open Access Journals (Sweden)

    Pengfei Sun

    Full Text Available Pose estimation aims at measuring the position and orientation of a calibrated camera using known image features. The pinhole model is the dominant camera model in this field. However, the imaging precision of this model is not accurate enough for an advanced pose estimation algorithm. In this paper, a new camera model, called incident ray tracking model, is introduced. More importantly, an advanced pose estimation algorithm based on the perspective ray in the new camera model, is proposed. The perspective ray, determined by two positioning points, is an abstract mathematical equivalent of the incident ray. In the proposed pose estimation algorithm, called perspective-ray-based scaled orthographic projection with iteration (PRSOI, an approximate ray-based projection is calculated by a linear system and refined by iteration. Experiments on the PRSOI have been conducted, and the results demonstrate that it is of high accuracy in the six degrees of freedom (DOF motion. And it outperforms three other state-of-the-art algorithms in terms of accuracy during the contrast experiment.

  20. Beam line from straight-section 16

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    The start of a long trail. The beam line from straight-section 16, where protons are fast ejected, is seen at the point where it crosses the Linac shielding wall as it leaves the PS en route to the ISR.

  1. Propagation of ovalization along straight pipes and elbows

    International Nuclear Information System (INIS)

    Millard, A.; Roche, R.L.

    1981-01-01

    The aim of this paper is to present analytical solutions for the propagation of evalization and the variation of the flexibility factor along pipe bends terminated by straight pipes or flanges, under in-plane bending, assuming an elastic material behaviour. The influence of the various strains in analysed in the simple case of a straight pipe, subjected to an elliptical cross-section shape deformation at one end. The results enlighten the very important part played by the distorsion in the propagation. They have been compared with finite elements solutions and with simple experiments. The solution is developed for an elbow terminated by a straight pipe or a flange, following the Von Karman's approach: local displacements are expanded in Fourier series, the coefficients of which vary along the curvilinear abscissa, like the rotation of the cross-section as a whole; the differential equations as well as the boundary conditions are found by minimization of the total potential energy of the assembly. The solutions are compared to existing and experimental results. (orig./HP)

  2. NuFact muon storage ring: study of a triangle design based on solenoid focusing decay straights

    Energy Technology Data Exchange (ETDEWEB)

    Meot, F. [Service Accelerateurs, Laboratoire de Physique Subatomique et de Cosmologie, Universite Joseph Fourier / CNRS-IN2P3, 53 Avenue des Martyrs, F-38026 Grenoble (France)]|[Commissariat a l' Energie Atomique, CEA, 31-33, rue de la Federation (Paris 15e), BP 510, 75752 Paris Cedex 15 (France); Reesy, G. [Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, Didcot OX11 0QX (United Kingdom)

    2006-06-15

    Properties of acceptance and beam transmission in a triangle design of the neutrino factory muon decay ring, with decay straights based on solenoidal focusing, are reported.The muon storage ring in the neutrino factory, NuFact, is located at the high energy end of the muon acceleration chain. It delivers the {mu}{sup +}/{mu}{sup -} decay neutrinos to physics detectors. The design of concern here, is a triangle geometry 20 GeV storage ring, upgradable to 50 GeV, (the parameters are given), which features two decay straight sections, each one aiming at a distant detector. The third straight section of the ring is devoted to tuning, collimation and RF. A particularity of the proposed design, is in its being based on solenoid focusing decay straights, which has the virtue of minimizing the betatron amplitudes, compared to equivalent quadrupole focusing. The solenoidal focusing ensures the requested ratio, for the r.m.s. divergences of the 20 GeV muon and the neutrino beam, of 0.1 for an assumed muon normalized r.m.s. emittance of 4800 {pi} mm mr (3 {pi} cm, total). The goal of the present work is to show the viability of this design, in particular as concerns the impact of the solenoid focusing on machine behavior. It addresses the questions of residual coupling, machine acceptance, and concludes with a computation of beam transmission over 1000 turns. The paper has the following structure: 1. Introduction; 2. Working hypothesis; 3. Building-up ray-tracing data; 3.1. Arcs; 3.2. Solenoid straight; 3.3. Tuning/Collimation/RF straight; 3.4. Full ring; 3.4.1. Beam envelopes; 3.4.2. Closed orbits; 3.4.3. Momentum dispersion; 3.5 Large amplitude tracking, preliminary tests; 4. Tracking, linear machine; 4.1. Large amplitude tracking; 4.1.1. 2-D horizontal initial conditions; 4.1.2. 2-D vertical initial conditions; 4.1.3. 4-D + {delta}p/p initial conditions; 4.2. Transmission, 4-D + {delta}p/p, no sextupoles; 4.2.1. {epsilon}{sub x} {epsilon}{sub z} = 3 {pi} cm (norm.), {delta

  3. NuFact muon storage ring: study of a triangle design based on solenoid focusing decay straights

    International Nuclear Information System (INIS)

    Meot, F.; Reesy, G.

    2006-06-01

    Properties of acceptance and beam transmission in a triangle design of the neutrino factory muon decay ring, with decay straights based on solenoidal focusing, are reported.The muon storage ring in the neutrino factory, NuFact, is located at the high energy end of the muon acceleration chain. It delivers the μ + /μ - decay neutrinos to physics detectors. The design of concern here, is a triangle geometry 20 GeV storage ring, upgradable to 50 GeV, (the parameters are given), which features two decay straight sections, each one aiming at a distant detector. The third straight section of the ring is devoted to tuning, collimation and RF. A particularity of the proposed design, is in its being based on solenoid focusing decay straights, which has the virtue of minimizing the betatron amplitudes, compared to equivalent quadrupole focusing. The solenoidal focusing ensures the requested ratio, for the r.m.s. divergences of the 20 GeV muon and the neutrino beam, of 0.1 for an assumed muon normalized r.m.s. emittance of 4800 π mm mr (3 π cm, total). The goal of the present work is to show the viability of this design, in particular as concerns the impact of the solenoid focusing on machine behavior. It addresses the questions of residual coupling, machine acceptance, and concludes with a computation of beam transmission over 1000 turns. The paper has the following structure: 1. Introduction; 2. Working hypothesis; 3. Building-up ray-tracing data; 3.1. Arcs; 3.2. Solenoid straight; 3.3. Tuning/Collimation/RF straight; 3.4. Full ring; 3.4.1. Beam envelopes; 3.4.2. Closed orbits; 3.4.3. Momentum dispersion; 3.5 Large amplitude tracking, preliminary tests; 4. Tracking, linear machine; 4.1. Large amplitude tracking; 4.1.1. 2-D horizontal initial conditions; 4.1.2. 2-D vertical initial conditions; 4.1.3. 4-D + δp/p initial conditions; 4.2. Transmission, 4-D + δp/p, no sextupoles; 4.2.1. ε x ε z = 3 π cm (norm.), δp/p = ±1%; 4.2.2. ε x ε z = 6 π cm (norm.), δp/p ±4

  4. Straight configuration saphenous vein transposition to popliteal artery for vascular access.

    Science.gov (United States)

    Caco, Gentian; Golemi, Dhurata; Likaj, Eriola

    2017-03-21

    The saphenous vein is commonly used as a vascular graft in peripheral artery surgery but rarely used for vascular access. The literature on straight configuration saphenous vein transposition to the popliteal artery is scarce. Here we present two cases of straight configuration saphenous vein transposition to the popliteal artery for vascular access, the surgical technique and respective follow-up. Two young men, aged 29 and 36 years, were chosen for lower-limb vascular access for hemodialysis. The first patient was paraplegic since birth. He used his arms to move so upper extremity vascular access was avoided. The second patient presented with an infected upper extremity arteriovenous graft (AVG) and after multiple closed AVFs he had no more available arm veins. Both patients received autologous lower extremity straight configuration saphenous vein transpositions to the popliteal artery under spinal anesthesia in May and October 2012, respectively. Cannulation of the fistula was allowed after one month. There were no early complications. Slight swelling on the leg appeared in one of the patients. Both fistulas were still functional after 36 and 32 months, respectively. The straight configuration saphenous vein transposition to popliteal artery is simple to perform, offers a long and straight segment for cannulation and may be a suitable autologous vascular access in selected patients.

  5. Qingping Straight Sword: The Last Remaining Chinese Sword System?

    Directory of Open Access Journals (Sweden)

    Stephan Berwick

    2012-07-01

    Full Text Available The following examination of classical Chinese straight sword (jian details the very rare Qingping straight sword system. The study meshes Chinese- and English-sourced research with a revealing interview (conducted by America’s senior Qingping disciples, Reza Momenan and Hon Lee with Lu Junhai—the grandmaster of this unique sword system. The author presents Qingping system as perhaps the only known, complete Chinese sword system surviving from China’s pre-Rebulican era (1911-1949.

  6. A mathematical model for camera calibration based on straight lines

    Directory of Open Access Journals (Sweden)

    Antonio M. G. Tommaselli

    2005-12-01

    Full Text Available In other to facilitate the automation of camera calibration process, a mathematical model using straight lines was developed, which is based on the equivalent planes mathematical model. Parameter estimation of the developed model is achieved by the Least Squares Method with Conditions and Observations. The same method of adjustment was used to implement camera calibration with bundles, which is based on points. Experiments using simulated and real data have shown that the developed model based on straight lines gives results comparable to the conventional method with points. Details concerning the mathematical development of the model and experiments with simulated and real data will be presented and the results with both methods of camera calibration, with straight lines and with points, will be compared.

  7. Cherry Picking: Virginity Loss Definitions Among Gay and Straight Cisgender Men.

    Science.gov (United States)

    Huang, Howard

    2017-08-03

    Virginity loss is a vital milestone in the development of one's sexual identity. Unfortunately, there is very little literature available studying virginity loss definitions among the wider straight population, and even less examining virginity loss among LGBTQ+ populations. The present study recruited 251 (45.4%) cisgender straight men and 114 (54.6%) cisgender gay men. An online, anonymous survey was administered to explore whether they considered various male-on-male (M-M) and male-on-female (M-F) sexual behaviors as constitutive of virginity loss. Results indicate that more gay men than straight considered M-M receptive anal intercourse (i.e., bottoming) and M-F penetrative anal intercourse to be constitutive of virginity loss. Results also indicate that both gay and straight men almost unanimously endorsed M-F penovaginal sex to be constitutive of virginity loss. This study is a first-step toward gaining a better understanding of LGBTQ+ virginity loss conceptualizations. Future research is strongly encouraged.

  8. Straight vegetable oils usage in a compression ignition engine - A review

    Energy Technology Data Exchange (ETDEWEB)

    Misra, R.D.; Murthy, M.S. [Mechanical Engineering Department, National Institute of Technology, Silchar 788010, Assam (India)

    2010-12-15

    The ever increasing fossil fuel usage and cost, environmental concern has forced the world to look for alternatives. Straight vegetable oils in compression ignition engine are a ready solution available, however, with certain limitations and with some advantages as reported by many researchers. A comprehensive and critical review is presented specifically pertaining to straight vegetable oils usage in diesel engine. A detailed record of historical events described. Research carried out specifically under Indian conditions and international research work on the usage of straight vegetable oils in the diesel engine is separately reviewed. Many researchers have reported that straight vegetable oils in small percentage blends with diesel when used lower capacity diesel engines have shown great promise with regards to the thermal performance as well exhaust emissions. This has been explained in detail. Finally based on the review of international as well as Indian research a SWOT analysis is carried out. The review concludes that there is still scope for research in this area. (author)

  9. Membranes with highly ordered straight nanopores by selective swelling of fast perpendicularly aligned block copolymers.

    Science.gov (United States)

    Yin, Jun; Yao, Xueping; Liou, Jiun-You; Sun, Wei; Sun, Ya-Sen; Wang, Yong

    2013-11-26

    Membranes with uniform, straight nanopores have important applications in diverse fields, but their application is limited by the lack of efficient producing methods with high controllability. In this work, we reported on an extremely simple and efficient strategy to produce such well-defined membranes. We demonstrated that neutral solvents were capable of annealing amphiphilic block copolymer (BCP) films of polystyrene-block-poly(2-vinylpyridine) (PS-b-P2VP) with thicknesses up to 600 nm to the perpendicular orientation within 1 min. Annealing in neutral solvents was also effective to the perpendicular alignment of block copolymers with very high molecular weights, e.g., 362 000 Da. Remarkably, simply by immersing the annealed BCP films in hot ethanol followed by drying in air, the originally dense BCP films were nondestructively converted into porous membranes containing highly ordered, straight nanopores traversing the entire thickness of the membrane (up to 1.1 μm). Grazing incident small-angle X-ray spectroscopy confirmed the hexagonal ordering of the nanopores over large areas. We found that the overflow of P2VP chains from their reservoir P2VP cylinders and the deformation of the PS matrix in the swelling process contributed to the transformation of the solid P2VP cylinders to empty straight pores. The pore diameters can be tuned by either changing the swelling temperatures or depositing thin layers of metal oxides on the preformed membranes via atomic layer deposition with a subnanometer accuracy. To demonstrate the application of the obtained porous membranes, we used them as templates and produced centimeter-scale arrays of aligned nanotubes of metal oxides with finely tunable wall thicknesses.

  10. Curved-straight neutron guide system with uniform spatial intensity distribution

    International Nuclear Information System (INIS)

    Mildner, D.F.R.; Cook, J.C.

    2008-01-01

    The spatial intensity distribution of neutrons emerging from a curved guide is asymmetric, and straight guide sections are sometimes appended to curved guides to make the intensity distribution more nearly uniform. For idealized uniform illumination and in the perfect reflectivity approximation, the spatial-angular acceptance at the exit of the combination can be made exactly uniform for a range of long wavelengths by using a sufficiently long straight section, together with a curved guide whose outer wall coating has a critical angle slightly greater than those of the other guide walls. We refer to this as a 'phase space tailoring guide' where the coatings on the inner wall and straight section are used to define the required divergence at the end of the guide. Increasing the critical angle of the outer wall of the curved section reduces the characteristic wavelength of the curved guide as well as the wavelength at which ideal uniformity can be obtained. The outer wall coating need only be of sufficiently high critical angle to fill the transmittable phase space area of the straight guide uniformly to adequately short wavelength

  11. Implicit Preferences for Straight People over Lesbian Women and Gay Men Weakened from 2006 to 2013

    Directory of Open Access Journals (Sweden)

    Erin C Westgate

    2015-07-01

    Full Text Available Legal rights and cultural attitudes towards lesbian women and gay men have shifted rapidly in the early 21st century. Using 683,976 visitors to Project Implicit from February 2006 to August 2013, we investigated whether shifts were also observable in implicit evaluations that occur outside of conscious awareness or control. Similar to public opinion polling, the estimated explicit preference for straight people over lesbian women and gay men was 26% weaker on the last day compared to the first. The estimated implicit preference for straight people declined by 13.4% over the same period. The largest shifts in implicit evaluations occurred among Hispanic, White, female, liberal, and young adult participants; the smallest shifts occurred among Black, Asian, male, conservative, and older adult participants. Societal change in evaluation of lesbian and gay people is not limited to what people are willing and able to report. However, change in implicit evaluation appears to be slower.

  12. Exact equivalent straight waveguide model for bent and twisted waveguides

    DEFF Research Database (Denmark)

    Shyroki, Dzmitry

    2008-01-01

    Exact equivalent straight waveguide representation is given for a waveguide of arbitrary curvature and torsion. No assumptions regarding refractive index contrast, isotropy of materials, or particular morphology in the waveguide cross section are made. This enables rigorous full-vector modeling...... of in-plane curved or helically wound waveguides with use of available simulators for straight waveguides without the restrictions of the known approximate equivalent-index formulas....

  13. Tomographic image via background subtraction using an x-ray projection image and a priori computed tomography

    International Nuclear Information System (INIS)

    Zhang Jin; Yi Byongyong; Lasio, Giovanni; Suntharalingam, Mohan; Yu, Cedric

    2009-01-01

    Kilovoltage x-ray projection images (kV images for brevity) are increasingly available in image guided radiotherapy (IGRT) for patient positioning. These images are two-dimensional (2D) projections of a three-dimensional (3D) object along the x-ray beam direction. Projecting a 3D object onto a plane may lead to ambiguities in the identification of anatomical structures and to poor contrast in kV images. Therefore, the use of kV images in IGRT is mainly limited to bony landmark alignments. This work proposes a novel subtraction technique that isolates a slice of interest (SOI) from a kV image with the assistance of a priori information from a previous CT scan. The method separates structural information within a preselected SOI by suppressing contributions to the unprocessed projection from out-of-SOI-plane structures. Up to a five-fold increase in the contrast-to-noise ratios (CNRs) was observed in selected regions of the isolated SOI, when compared to the original unprocessed kV image. The tomographic image via background subtraction (TIBS) technique aims to provide a quick snapshot of the slice of interest with greatly enhanced image contrast over conventional kV x-ray projections for fast and accurate image guidance of radiation therapy. With further refinements, TIBS could, in principle, provide real-time tumor localization using gantry-mounted x-ray imaging systems without the need for implanted markers.

  14. Comparison of 21G curved and straight phacotips designs in transversal microcoaxial phacoemulsification

    Directory of Open Access Journals (Sweden)

    Süleyman Demircan

    2015-12-01

    Full Text Available AIM:To compare the intraoperative performance and postoperative outcomes after microcoaxial torsional phacoemulsification using the straight and the curved phacotip configurations.METHODS:Cataracts were treated using 2.2mm microcoaxial transversal phacoemulsification with either a 30°straight or 30° curved phaco tip. Intraoperative measurements analyzed included the average ultrasound(U/Spower, the total phacoemulsification time, and the effective phacoemulsification time(EPT. The central endothelial cell density(ECDand the central corneal thickness(CCTwere evaluated preoperatively and postoperatively at 1, 7 and 30d after surgery using noncontact specular microscopy. RESULTS:The study enrolled a total of 190 eyes(190 patients, 95 eyes in the curved tip group and 95 eyes in straight tip group. Intraoperative measurements showed significantly reduced total phacoemulsification time, and EPT in the curved-tip group, compared to the straight-tip group(Pst-3rd quartilesand 18.0(9.0-30.0s in curved-tip group, and 38.8(16.5-73.5s and 26.0(11.0-49.0s in the straight-tip group, respectively. CONCLUSION:Transversal phacoemulsification performed with a curved tip provided more effective lens removal with a less total UST and EPT in all grades, except for grades IV, compared to a straight tip.

  15. An intersection graph of straight lines

    DEFF Research Database (Denmark)

    Thomassen, Carsten

    2002-01-01

    G. Ehrlich, S. Even, and R.E. Tarjan conjectured that the graph obtained from a complete 3 partite graph K4,4,4 by deleting the edges of four disjoint triangles is not the intersection graph of straight line segments in the plane. We show that it is....

  16. Straight-line string with curvature

    International Nuclear Information System (INIS)

    Solov'ev, L.D.

    1995-01-01

    Classical and quantum solutions for the relativistic straight-line string with arbitrary dependence on the world surface curvature are obtained. They differ from the case of the usual Nambu-Goto interaction by the behaviour of the Regge trajectory which in general can be non-linear. A regularization of the action is considered and a comparison with relativistic point with curvature is made. 5 refs

  17. PHYSICAL AND CHEMICAL PROPERTIES AND STRUCTURAL-GROUP COMPOSITION OF STRAIGHT-RUN FRACTIONS OF IRAQI OILFIELDS

    Directory of Open Access Journals (Sweden)

    С.В. Бойченко

    2012-10-01

    Full Text Available  Iraq is one of the richest countries of the Near East in terms of oil reserves. Only Saudi Arabia has greater hydrocarbon reserves. Despite the fact that commercial oil production is implemented since 1927, the harsh social and political and economic situation added with long-time military conflict had totally destroyed           oil processing infrastructure. Considering this factor, one of the key tasks for this country is building of  a new, contemporary oil processing infrastructure. Thus, complex study of oils as well as their  straight-run fractions is a requirement for preparation of the projects of oil processing plants that are consistent with current hard requirements. This material contents results of physical and chemical studies  of straight-run oil fractions as gasoline, Diesel oil, and heavy oils. Properties of fractions shown below, their potential related to export oil products are essential data for preparation of process flow diagram of the oil processing plant.

  18. Gender, health behavior, and intimate relationships: lesbian, gay, and straight contexts.

    Science.gov (United States)

    Reczek, Corinne; Umberson, Debra

    2012-06-01

    Many studies focus on health behavior within the context of intimate ties. However, this literature is limited by reliance on gender socialization theory and a focus on straight (i.e., heterosexual) marriage. We extend this work with an analysis of relationship dynamics around health behavior in 20 long-term straight marriages as well as 15 gay and 15 lesbian long-term cohabiting partnerships in the United States (N = 100 individual in-depth interviews). We develop the concept of "health behavior work" to align activities done to promote health behavior with theories on unpaid work in the home. Respondents in all couple types describe specialized health behavior work, wherein one partner works to shape the other partner's health behavior. In straight couples, women perform the bulk of specialized health behavior work. Most gay and lesbian respondents-but few straight respondents--also describe cooperative health behavior work, wherein partners mutually influence one another's health behaviors. Findings suggest that the gendered relational context of an intimate partnership shapes the dynamics of and explanations for health behavior work. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Active interlock system for high power insertion devices in the x-ray ring

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    In modern synchrotron radiation rings photon beams generated by high power insertion devices (IDs) may be sufficiently intense to cause severe thermal damage to the machine vacuum chamber if mis-steered. Thus when operating a storage ring with the IDs, great care must be exercised to prevent mis-steering of the electron beam orbit. At present, the X-ray ring operates with three IDs, namely two hybrid wigglers (HBW) at X-21 and X-25,a nd a 5-Tesla superconducting wiggler at X-17. All wigglers are located in low-beta straight sections. In the straight sections. In the straight sections, beam orbit may be deflected by as much as ±8 mrad without scraping the chamber wall. For various reasons it was not possible to design the X-ray ring vacuum chamber to be safe under all possible operating conditions, however, the chamber is safe for i < 7 mA, all horizontal beam deflection angles and for vertical angles < ± 2.5 mrad. To protect the machine vacuum chamber from damage due to mis-steered beams, and interlock system has been developed and installed. This system utilizes active beam position detectors which continuously monitor beam motion in each of the ID straight sections and logic circuitry which interrupts the RF and dumps the stored beam in the case of a fault

  20. Analytical algorithm for the generation of polygonal projection data for tomographic reconstruction

    International Nuclear Information System (INIS)

    Davis, G.R.

    1996-01-01

    Tomographic reconstruction algorithms and filters can be tested using a mathematical phantom, that is, a computer program which takes numerical data as its input and outputs derived projection data. The input data is usually in the form of pixel ''densities'' over a regular grid, or position and dimensions of simple, geometrical objects. The former technique allows a greater variety of objects to be simulated, but is less suitable in the case when very small (relative to the ray-spacing) features are to be simulated. The second technique is normally used to simulate biological specimens, typically a human skull, modelled as a number of ellipses. This is not suitable for simulating non-biological specimens with features such as straight edges and fine cracks. We have therefore devised an algorithm for simulating objects described as a series of polygons. These polygons, or parts of them, may be smaller than the ray-spacing and there is no limit, except that imposed by computing resources, on the complexity, number or superposition of polygons. A simple test of such a phantom, reconstructed using the filtered back-projection method, revealed reconstruction artefacts not normally seen with ''biological'' phantoms. (orig.)

  1. Intubation of prehospital patients with curved laryngoscope blade is more successful than with straight blade.

    Science.gov (United States)

    Alter, Scott M; Haim, Eithan D; Sullivan, Alex H; Clayton, Lisa M

    2018-02-17

    Direct laryngoscopy can be performed using curved or straight blades, and providers usually choose the blade they are most comfortable with. However, curved blades are anecdotally thought of as easier to use than straight blades. We seek to compare intubation success rates of paramedics using curved versus straight blades. Design: retrospective chart review. hospital-based suburban ALS service with 20,000 annual calls. prehospital patients with any direct laryngoscopy intubation attempt over almost 9years. First attempt and overall success rates were calculated for attempts with curved and straight blades. Differences between the groups were calculated. 2299 patients were intubated by direct laryngoscopy. 1865 had attempts with a curved blade, 367 had attempts with a straight blade, and 67 had attempts with both. Baseline characteristics were similar between groups. First attempt success was 86% with a curved blade and 73% with a straight blade: a difference of 13% (95% CI: 9-17). Overall success was 96% with a curved blade and 81% with a straight blade: a difference of 15% (95% CI: 12-18). There was an average of 1.11 intubation attempts per patient with a curved blade and 1.13 attempts per patient with a straight blade (2% difference, 95% CI: -3-7). Our study found a significant difference in intubation success rates between laryngoscope blade types. Curved blades had higher first attempt and overall success rates when compared to straight blades. Paramedics should consider selecting a curved blade as their tool of choice to potentially improve intubation success. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. X-ray emission spectroscopy applied to glycine adsorbed on Cu(110): An atom and symmetry projected view

    Energy Technology Data Exchange (ETDEWEB)

    Hasselstroem, J.; Karis, O.; Weinelt, M. [Uppsala Univ. (Sweden)] [and others

    1997-04-01

    When a molecule is adsorbed on a metal surface by chemical bonding new electronic states are formed. For noble and transition metals these adsorption-induced states overlap with the much more intense metal d-valence band, making them difficult to probe by for instance direct photoemission. However, it has recently been shown that X-ray emission spectroscopy (XES) can be applied to adsorbate systems. Since the intermediate state involves a core hole, this technique has the power to project out the partial density of states around each atomic site. Both the excitation and deexcitation processes are in general governed by the dipole selection rules. For oriented system, it is hence possible to obtain a complete separation into 2p{sub x}, 2p{sub y} and 2p{sub z} contributions using angular resolved measurements. The authors have applied XES together with other core level spectroscopies to glycine adsorption on Cu(110). Glycine (NH{sub 2}CH{sub 2}COOH) is the smallest amino acid and very suitable to study by core level spectroscopy since it has several functional groups, all well separated in energy by chemical shifts. Its properties are futhermore of biological interest. In summary, the authors have shown that it is possible to apply XES to more complicated molecular adsorbates. The assignment of different electronic states is however not as straight forward as for simple diatomic molecules. For a complete understanding of the redistribution and formation of new electronic states associated with the surface chemical bond, experimental data must be compared to theoretical calculations.

  3. The exponential edge-gradient effect in x-ray computed tomography

    International Nuclear Information System (INIS)

    Joseph, P.M.

    1981-01-01

    The exponential edge-gradient effect must arise in any X-ray transmission CT scanner whenever long sharp edges of high contrast are encountered. The effect is non-linear and is due to the interaction of the exponential law of X-ray attenuation and the finite width of the scanning beam in the x-y plane. The error induced in the projection values is proved to be always negative. While the most common effect is lucent streaks emerging from single straight edges, it is demonstrated that dense streaks from pairs of edges are possible. It is shown that an exact correction of the error is possible only under very special (and rather unrealistic) circumstances in which an infinite number of samples per beam width are available and all thin rays making up the beam can be considered parallel. As a practical matter, nevertheless, increased sample density is highly desirable in making good approximate corrections; this is demonstrated with simulated scans. Two classes of approximate correction algorithms are described and their effectiveness evaluated on simulated CT phantom scans. One such algorithm is also shown to work well with a real scan of a physical phantom on a machine that provides approximately four samples per beam width. (author)

  4. Transmission of fast highly charged ions through straight and tapered glass capillaries

    International Nuclear Information System (INIS)

    Ayyad, Asma M; Keerthisinghe, D; Kayani, A; Tanis, J A; Dassanayake, B S; Ikeda, T

    2013-01-01

    The transmission of 1 and 3 MeV protons through a borosilicate straight glass capillary and a tapered glass capillary was investigated. The straight capillary had a diameter of ∼0.18 mm and a length of ∼14.4 mm, while the tapered capillary had an inlet diameter of ∼0.71 mm, an outlet diameter of ∼0.10 mm and a length of ∼28 mm. The results show that the 1 and 3 MeV protons traverse through both samples without energy loss, while the tapered capillary showed better transmission than the straight capillary. (paper)

  5. Effect of iron catalyst thickness on vertically aligned carbon nanotube forest straightness for CNT-MEMS

    International Nuclear Information System (INIS)

    Moulton, Kellen; Jensen, Brian D; Morrill, Nicholas B; Konneker, Adam M; Vanfleet, Richard R; Allred, David D; Davis, Robert C

    2012-01-01

    This paper examines the effect of iron catalyst thickness on the straightness of growth of carbon nanotubes (CNTs) for microelectromechanical systems fabricated using the CNT-templated-microfabrication (CNT-M) process. SEM images of samples grown using various iron catalyst thicknesses show that both straight sidewalls and good edge definition are achieved using an iron thickness between 7 and 8 nm. Below this thickness, individual CNTs are well aligned, but the sidewalls of CNT forests formed into posts and long walls are not always straight. Above this thickness, the CNT forest sidewalls are relatively straight, but edge definition is poor, with significantly increased sidewall roughness. The proximity of a device or feature to other regions of iron catalyst also affects CNT growth. By using an iron catalyst thickness appropriate for straight growth, and by adding borders of iron around features or devices, a designer can greatly improve straightness of growth for CNT-MEMS. (paper)

  6. X-ray nanoprobe project at Taiwan Photon Source

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Gung-Chian, E-mail: gcyin@nsrrc.org.tw; Chang, Shih-Hung; Chen, Bo-Yi; Chen, Huang-Yeh; Lin, Bi-Hsuan; Tseng, Shao-Chin; Lee, Chien-Yu; Wu, Jian-Xing; Tang, Mau-Tsu [National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan (China); Wu, Shao-Yun [National Tsing-Hua University, Hsinchu 30076, Taiwan (China)

    2016-07-27

    The hard X-ray nanoprobe facility at Taiwan Photon Source (TPS) provides versatile X-ray analysis techniques, with tens of nanometer resolution, including XRF, XAS, XEOL, projection microscope, CDI, etc. Resulting from the large numerical aperture obtained by utilizing Montel KB mirrors, the beamline with a moderate length 75 meters can conduct similar performance with those beamlines longer than 100 meters. The two silica-made Montel mirrors are 45 degree cut and placed in a V-shape to eliminate the gap loss and the deformation caused by gravity. The slope error of the KB mirror pair is less than 0.04 µrad accomplished by elastic emission machining (EEM) method. For the beamline, a horizontal DCM and two-stage focusing in horizontal direction is applied. For the endstation, a combination of SEM for quickly positioning the sample, a fly scanning system with laser interferometers, a precise temperature control system, and a load lock transfer system will be implemented. In this presentation, the design and construction progress of the beamline and endstation is reported. The endstation is scheduled to be in commissioning phase in 2016.

  7. Hard X-ray Sources for the Mexican Synchrotron Project

    International Nuclear Information System (INIS)

    Reyes-Herrera, Juan

    2016-01-01

    One of the principal tasks for the design of the Mexican synchrotron was to define the storage ring energy. The main criteria for choosing the energy come from studying the electromagnetic spectrum that can be obtained from the synchrotron, because the energy range of the spectrum that can be obtained will determine the applications available to the users of the future light source. Since there is a public demand of hard X-rays for the experiments in the synchrotron community users from Mexico, in this work we studied the emission spectra from some hard X-ray sources which could be the best options for the parameters of the present Mexican synchrotron design. The calculations of the flux and the brightness for one Bending Magnet and four Insertion Devices are presented; specifically, for a Superconducting Bending Magnet (SBM), a Superconducting Wiggler (SCW), an In Vacuum Short Period Undulator (IV-SPU), a Superconducting Undulator (SCU) and for a Cryogenic Permanent Magnet Undulator (CPMU). Two commonly available synchrotron radiation programs were used for the computation (XOP and SRW). From the results, it can be concluded that the particle beam energy from the current design is enough to have one or more sources of hard X-rays. Furthermore, a wide range of hard X-ray region can be covered by the analyzed sources, and the choice of each type should be based on the specific characteristics of the X-ray beam to perform the experiments at the involved beamline. This work was done within the project Fomix Conacyt-Morelos ”Plan Estrategico para la construccion y operación de un Sincrotron en Morelos” (224392). (paper)

  8. Hard X-ray Sources for the Mexican Synchrotron Project

    Science.gov (United States)

    Reyes-Herrera, Juan

    2016-10-01

    One of the principal tasks for the design of the Mexican synchrotron was to define the storage ring energy. The main criteria for choosing the energy come from studying the electromagnetic spectrum that can be obtained from the synchrotron, because the energy range of the spectrum that can be obtained will determine the applications available to the users of the future light source. Since there is a public demand of hard X-rays for the experiments in the synchrotron community users from Mexico, in this work we studied the emission spectra from some hard X-ray sources which could be the best options for the parameters of the present Mexican synchrotron design. The calculations of the flux and the brightness for one Bending Magnet and four Insertion Devices are presented; specifically, for a Superconducting Bending Magnet (SBM), a Superconducting Wiggler (SCW), an In Vacuum Short Period Undulator (IV-SPU), a Superconducting Undulator (SCU) and for a Cryogenic Permanent Magnet Undulator (CPMU). Two commonly available synchrotron radiation programs were used for the computation (XOP and SRW). From the results, it can be concluded that the particle beam energy from the current design is enough to have one or more sources of hard X-rays. Furthermore, a wide range of hard X-ray region can be covered by the analyzed sources, and the choice of each type should be based on the specific characteristics of the X-ray beam to perform the experiments at the involved beamline. This work was done within the project Fomix Conacyt-Morelos ”Plan Estrategico para la construccion y operación de un Sincrotron en Morelos” (224392).

  9. The SPARX Project R&D Activity towards X-rays FEL Sources

    CERN Document Server

    Alesini, David; Bertolucci, Sergio; Biagini, M E; Boni, R; Boscolo, Manuela; Castellano, Michele; Clozza, A; Di Pirro, G; Drago, A; Esposito, A; Ferrario, Massimo; Filippetto, D; Fusco, V; Gallo, A; Ghigo, A; Guiducci, Susanna; Incurvati, M; Ligi, C; Marcellini, F; Migliorati, Mauro; Mostacci, Andrea; Palumbo, Luigi; Pellegrino, L; Preger, Miro; Raimondi, Pantaleo; Ricci, R; Sanelli, C; Serio, Mario; Sgamma, F; Spataro, Bruno; Stecchi, A; Stella, A; Tazzioli, Franco; Vaccarezza, Cristina; Vescovi, Mario; Vicario, C

    2004-01-01

    SPARX is an evolutionary project proposed by a collaboration among ENEA-INFN-CNR-Università di Roma Tor Vergata aiming at the construction of a FEL-SASE X-ray source in the Tor Vergata Campus. The first phase of the SPARX project, funded by Government Agencies, will be focused on the R&D activity on critical components and techniques for future X-ray facilities. The R&D plans for the FEL source will be developped along two lines: (a) use of the SPARC high brightness photo-injector to develop experimental test on RF compression techniques and other beam physics issues, like emittance degradation in magnetic compressors due to CSR; (b) development of new undulator design concepts and up-grading of the FEL SPARC source to enhance the non linear harmonic generation mechanism, design and test of e-beam conditioning, prebunching and seeding. A parallel program will be aimed at the development of high repetition rate S-band gun, high Quantum Efficiency cathodes, high gradient X-band RF acceleratin...

  10. Effects of cavity on leakage loss in straight-through labyrinth seals

    International Nuclear Information System (INIS)

    Zhao, W; Nielsen, T K; Billdal, J T

    2010-01-01

    Labyrinth seals are widely used in rotating fluid machinery, due to its low-cost, simplicity and reliability. A straight-through labyrinth seal consists of a clearance between the stator and rotor, and sometimes cavities which are included on the stator or the rotator side. In this type of seals, making cavities are an effective way to convert turbulence kinetic energy into thermal energy by forming turbulence vortices, thereby reducing pressure difference and leakage flow. In this paper, the effect of cavities on leakage loss in straight-through labyrinth seals are studied by changing cavity dimensions such as depth and length, cavity number and cavity location. The influences of unilateral cavities and bilateral cavities on the leakage loss in straight-through labyrinth seals are also compared. The fluid flow characteristics through straight-through labyrinth seals were obtained by using viscous flow analysis along with a standard k-ωturbulence model. The cavity dimensions and cavity numbers have significant effects on the leakage as well as on the flow pattern in the seal. The bilateral cavity has better leakage performance than the unilateral cavity when cavity dimensions are identical. However, the cavity location shows no significant influences on the leakage flow.

  11. Implanting straight into cochlea risks the facial nerve: a Cartesian coordinate study.

    Science.gov (United States)

    Deshpande, Anita S; Wendell Todd, N

    2016-12-01

    To describe the straight-into-cochlea line that affords the best access for an electrode array to enter via the round window, and how this line relates to the facial nerve, the incus, and mastoid size. The straight-into-cochlea line is important to minimize the cochlear trauma and maximize the likelihood of placement into the scala tympani. High-resolution CT scans were obtained for ten craniums with the extremes of large (N = 5) and small (N = 5) mastoid pneumatization; the specimens were from a series of 41 ear normal craniums. Using FIJI, a publicly available software program, the straight-into-cochlea insertion line was determined by defining the x-y-z coordinates of the middle of the round window and a point 6.0 mm into the cochlea on its centrifugal wall. Then, from the extended straight-into-cochlea insertion line, we determined the shortest perpendicular distance to the middle of the fallopian canal, and from that "fallopian point" to the apex of the posterior process of the incus. We found good repeatability of measurements. We found the extended straight-into-cochlea insertion lines routinely close to or in the midst of the fallopian canal (50 % ≤ 1.0 mm). We found the lines 4.7-7.8 mm from the apex of the posterior process of the incus. Line positions relative to "fallopian point" and incus showed no relation to mastoid pneumatization. For the distance "fallopian point" to incus, bilateral symmetry was suggested. Using landmarks registered in an x-y-z coordinate system, straight-into-cochlea insertion via the round window puts the facial nerve at risk.

  12. Power spectrum analysis of the x-ray scatter signal in mammography and breast tomosynthesis projections.

    Science.gov (United States)

    Sechopoulos, Ioannis; Bliznakova, Kristina; Fei, Baowei

    2013-10-01

    To analyze the frequency domain characteristics of the signal in mammography images and breast tomosynthesis projections with patient tissue texture due to detected scattered x-rays. Acquisitions of x-ray projection images of 19 different patient breasts were simulated using previously acquired volumetric patient images. Acquisition of these images was performed with a dedicated breast CT prototype system, and the images were classified into voxels representing skin, adipose, and glandular tissue with a previously validated automated algorithm. The classified three dimensional images then underwent simulated mechanical compression representing that which is performed during acquisition of mammography and breast tomosynthesis images. The acquisition of projection images of each patient breast was simulated using Monte Carlo methods with each simulation resulting in two images: one of the primary (non-scattered) signal and one of the scatter signal. To analyze the scatter signal for both mammography and breast tomosynthesis, two projections images of each patient breast were simulated, one with the x-ray source positioned at 0° (mammography and central tomosynthesis projection) and at 30° (wide tomosynthesis projection). The noise power spectra (NPS) for both the scatter signal alone and the total signal (primary + scatter) for all images were obtained and the combined results of all patients analyzed. The total NPS was fit to the expected power-law relationship NPS(f) = k/f β and the results were compared with those previously published on the power spectrum characteristics of mammographic texture. The scatter signal alone was analyzed qualitatively and a power-law fit was also performed. The mammography and tomosynthesis projections of three patient breasts were too small to analyze, so a total of 16 patient breasts were analyzed. The values of β for the total signal of the 0° projections agreed well with previously published results. As expected, the scatter

  13. Cochlear implantation in Mondini's deformity: could the straight electrode array with length of 31 mm be fully inserted?

    Science.gov (United States)

    Sun, Jia-Qiang; Sun, Jing-Wu; Hou, Xiao-Yan

    2017-07-01

    The straight electrode array with length of 31 mm can be fully inserted using round window insertion in cochlear implantation with Mondini's deformity. It is a safe and effective process, but also a challenging task of the full implantation in children with Mondini's deformity. The aim of this study is to discuss whether the straight electrode array with a length of 31 mm could be fully inserted in cochlear implantation with Mondini's deformity. A chart review of 30 patients undergoing cochlear implantation with Mondini's deformity using the electrode array with length of 31 mm was undertaken from January 2012 and December 2015 in Anhui Provincial Hospital. Full insertion of the straight electrode array with length of 31 mm were performed successfully in all patients with Mondini's deformity using round window insertion. Resistance was not encountered while introducing the electrodes. Ten of 30 patients had cerebrospinal fluid drainage during cochlear implantation. Cerebrospinal fluid drainage was controlled with small pieces of temporalis fascia packing round window in all patients. Intra-operative neural response telemetry was performed in all patients, and results were good. The result of X-ray showed proper placement of the cochlear implant electrode array. During surgery, no patients had experienced any immediate or delayed post-operative complications such as wound infection, intracranial complication, extrusion, or migration of the implant during an average follow-up period of 6-36 months.

  14. Towards the installation and use of an extended array for cosmic ray detection The EEE Project

    CERN Document Server

    Abbrescia, M; An, S; Antolini, R; Badala, A; Baek, Y W; Baldini Ferroli, R; Bencivenni, G; Blanco, F; Bressan, E; Chiavassa, A; Chiri,C; Cicalò, C; Cifarelli, L; Coccia, E; Coccetti, F; De Caro, A; De Gruttola, D; De Pasquale, S; D'Incecco, M; Fabbri, F L; Frolov, V; Garbini, M; Garnaccia, C; Gustavino, C; Hatzifotiadou, D; Imponente, G; Kim, J S; Kim, M M; La Rocca, P; Librizzi, F; Maggiora, A; Menghetti, H; Miozzi, S; Moro, R; Noferini, F; Pagano, P; Panareo, M; Pappalardo, G S; Petta, C; Piragino, G; Preghenella, R; Riggi, F; Romano, F; Russo, G; Sartorelli, G; Sbarra, C; Scioli, G; Selvi, M; Serci, S; Siddi, E; Wenninger, H; Williams, M C S; Zampolli, C; Zichichi, A; Zuyeuski, R

    2009-01-01

    The Extreme Energy Events (EEE) project started to use an array of cosmic ray telescopes for muon detection, distributed over the italian territory. The use of such telescopes, based on Multigap Resistive Plate Chambers (MRPC) allows the study of the local muon flux, the detection of cosmic ray showers and the search for correlations between distant showers. The project is also intended to involve high school teams in an advanced research work. The present status of the installation and the first physics results are discussed here.

  15. Towards the installation and use of an extended array for cosmic ray detection: The EEE Project

    Energy Technology Data Exchange (ETDEWEB)

    Abbrescia, M. [INFN and Department of Physics, University of Bari (Italy); Alici, A. [INFN and Department of Physics, University of Bologna (Italy); An, S. [World Laboratory, Geneva (Switzerland); Antolini, R. [INFN, Laboratori Nazionali del Gran Sasso (Italy); Badala, A. [INFN and Department of Physics and Astronomy, University of Catania (Italy); Baek, Y.W. [Department of Physics, Kangnung National University (Korea, Republic of); CERN, Geneva (Switzerland); Baldini Ferroli, R. [Museo Storico della Fisica, Centro Studi e Ricerche E.Fermi, Roma (Italy); INFN, Laboratori Nazionali di Frascati (Italy); Bencivenni, G. [INFN, Laboratori Nazionali di Frascati (Italy); Museo Storico della Fisica, Centro Studi e Ricerche E.Fermi, Roma (Italy); Blanco, F. [INFN and Department of Physics and Astronomy, University of Catania (Italy); Bressan, E. [INFN and Department of Physics, University of Bologna (Italy); Chiavassa, A. [INFN and Department of Physics, University of Torino (Italy); Chiri, C. [INFN and Department of Physics, University of Lecce (Italy); Museo Storico della Fisica, Centro Studi e Ricerche E.Fermi, Roma (Italy); Cicalo, C. [INFN and Department of Physics, University of Cagliari (Italy); Cifarelli, L. [INFN and Department of Physics, University of Bologna (Italy); Coccia, E. [INFN, Laboratori Nazionali del Gran Sasso (Italy); Coccetti, F. [Museo Storico della Fisica, Centro Studi e Ricerche E.Fermi, Roma (Italy); De Caro, A.; De Gruttola, D.; De Pasquale, S. [INFN and Department of Physics, University of Salerno (Italy); D' Incecco, M. [INFN, Laboratori Nazionali del Gran Sasso (Italy)

    2009-05-15

    The Extreme Energy Events (EEE) project started to use an array of cosmic ray telescopes for muon detection, distributed over the italian territory. The use of such telescopes, based on Multigap Resistive Plate Chambers (MRPC) allows the study of the local muon flux, the detection of cosmic ray showers and the search for correlations between distant showers. The project is also intended to involve high school teams in an advanced research work. The present status of the installation and the first physics results are discussed here.

  16. The appearance potency of gay and straight men’s websites

    OpenAIRE

    Jankowski, G.; Slater, A.; Tiggemann, M.; Fawkner, H.

    2016-01-01

    Gay men's greater body dissatisfaction compared to straight men has been explained as a result of gay men’s more 'appearance potent' subculture. This study aimed to critically appraise this explanation by assessing images of men and women for their physical characteristics and objectification across 8 popular gay and straight men's dating and porn websites. 1,415 images of men and 715 images of women across the website’s main pages were coded. Results showed that the gay men's websites featur...

  17. A simple algorithm for computing positively weighted straight skeletons of monotone polygons☆

    Science.gov (United States)

    Biedl, Therese; Held, Martin; Huber, Stefan; Kaaser, Dominik; Palfrader, Peter

    2015-01-01

    We study the characteristics of straight skeletons of monotone polygonal chains and use them to devise an algorithm for computing positively weighted straight skeletons of monotone polygons. Our algorithm runs in O(nlog⁡n) time and O(n) space, where n denotes the number of vertices of the polygon. PMID:25648376

  18. A simple algorithm for computing positively weighted straight skeletons of monotone polygons.

    Science.gov (United States)

    Biedl, Therese; Held, Martin; Huber, Stefan; Kaaser, Dominik; Palfrader, Peter

    2015-02-01

    We study the characteristics of straight skeletons of monotone polygonal chains and use them to devise an algorithm for computing positively weighted straight skeletons of monotone polygons. Our algorithm runs in [Formula: see text] time and [Formula: see text] space, where n denotes the number of vertices of the polygon.

  19. 26 CFR 7.57(d)-1 - Election with respect to straight line recovery of intangibles.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 14 2010-04-01 2010-04-01 false Election with respect to straight line recovery... ACT OF 1976 § 7.57(d)-1 Election with respect to straight line recovery of intangibles. (a) Purpose... Tax Reform Act of 1976. Under this election taxpayers may use cost depletion to compute straight line...

  20. Straight-Line Target Tracking for Unmanned Surface Vehicles

    Directory of Open Access Journals (Sweden)

    Morten Breivik

    2008-10-01

    Full Text Available This paper considers the subject of straight-line target tracking for unmanned surface vehicles (USVs. Target-tracking represents motion control scenarios where no information about the target behavior is known in advance, i.e., the path that the target traverses is not defined apriori. Specifically, this work presents the design of a motion control system which enables an underactuated USV to track a target that moves in a straight line at high speed. The motion control system employs a guidance principle originally developed for interceptor missiles, as well as a novel velocity controller inspired by maneuverability and agility concepts found in fighter aircraft literature. The performance of the suggested design is illustrated through full-scale USV experiments in the Trondheimsfjord.

  1. Neck Muscle Moment Arms Obtained In-Vivo from MRI: Effect of Curved and Straight Modeled Paths.

    Science.gov (United States)

    Suderman, Bethany L; Vasavada, Anita N

    2017-08-01

    Musculoskeletal models of the cervical spine commonly represent neck muscles with straight paths. However, straight lines do not best represent the natural curvature of muscle paths in the neck, because the paths are constrained by bone and soft tissue. The purpose of this study was to estimate moment arms of curved and straight neck muscle paths using different moment arm calculation methods: tendon excursion, geometric, and effective torque. Curved and straight muscle paths were defined for two subject-specific cervical spine models derived from in vivo magnetic resonance images (MRI). Modeling neck muscle paths with curvature provides significantly different moment arm estimates than straight paths for 10 of 15 neck muscles (p straight lines to model muscle paths can lead to overestimating neck extension moment. However, moment arm methods for curved paths should be investigated further, as different methods of calculating moment arm can provide different estimates.

  2. Commissioning of the Cryogenics of the LHC Long Straight Sections

    CERN Document Server

    Perin, A; Claudet, S; Darve, C; Ferlin, G; Millet, F; Parente, C; Rabehl, R; Soubiran, M; van Weelderen, R; Wagner, U

    2010-01-01

    The LHC is made of eight circular arcs interspaced with eight Long Straight Sections (LSS). Most powering interfaces to the LHC are located in these sections where the particle beams are focused and shaped for collision, cleaning and acceleration. The LSSs are constituted of several unique cryogenic devices and systems like electrical feed-boxes, standalone superconducting magnets, superconducting links, RF cavities and final focusing superconducting magnets. This paper presents the cryogenic commissioning and the main results obtained during the first operation of the LHC Long Straight Sections.

  3. Commissioning of the cryogenics of the LHC long straight sections

    International Nuclear Information System (INIS)

    Perin, A.; Casas-Cubillos, J.; Claudet, S.; Darve, C.; Ferlin, G.; Millet, F.; Parente, C.; Rabehl, R.; Soubiran, M.; van Weelderen, R.; Wagner, U.

    2010-01-01

    The LHC is made of eight circular arcs interspaced with eight Long Straight Sections (LSS). Most powering interfaces to the LHC are located in these sections where the particle beams are focused and shaped for collision, cleaning and acceleration. The LSSs are constituted of several unique cryogenic devices and systems like electrical feed-boxes, standalone superconducting magnets, superconducting links, RF cavities and final focusing superconducting magnets. This paper presents the cryogenic commissioning and the main results obtained during the first operation of the LHC Long Straight Sections.

  4. Model-based sphere localization (MBSL) in x-ray projections

    Science.gov (United States)

    Sawall, Stefan; Maier, Joscha; Leinweber, Carsten; Funck, Carsten; Kuntz, Jan; Kachelrieß, Marc

    2017-08-01

    The detection of spherical markers in x-ray projections is an important task in a variety of applications, e.g. geometric calibration and detector distortion correction. Therein, the projection of the sphere center on the detector is of particular interest as the used spherical beads are no ideal point-like objects. Only few methods have been proposed to estimate this respective position on the detector with sufficient accuracy and surrogate positions, e.g. the center of gravity, are used, impairing the results of subsequent algorithms. We propose to estimate the projection of the sphere center on the detector using a simulation-based method matching an artificial projection to the actual measurement. The proposed algorithm intrinsically corrects for all polychromatic effects included in the measurement and absent in the simulation by a polynomial which is estimated simultaneously. Furthermore, neither the acquisition geometry nor any object properties besides the fact that the object is of spherical shape need to be known to find the center of the bead. It is shown by simulations that the algorithm estimates the center projection with an error of less than 1% of the detector pixel size in case of realistic noise levels and that the method is robust to the sphere material, sphere size, and acquisition parameters. A comparison to three reference methods using simulations and measurements indicates that the proposed method is an order of magnitude more accurate compared to these algorithms. The proposed method is an accurate algorithm to estimate the center of spherical markers in CT projections in the presence of polychromatic effects and noise.

  5. A generalized, periodic nonlinearity-reduced interferometer for straightness measurements

    International Nuclear Information System (INIS)

    Wu Chienming

    2008-01-01

    Periodic nonlinearity is a systematic error limiting the accuracy of displacement measurements at the nanometer level. However, an interferometer with a displacement measurement accuracy of less than 1 nm is required in nanometrology and in fundamental scientific research. To meet this requirement, a generalized, periodic nonlinearity-reduced interferometer, based on three construction principles has been developed for straightness measurements. These three construction principles have resulted in an interferometer with a highly stable design with reduced periodic nonlinearity. Verifications by a straightness interferometer have demonstrated that the periodic nonlinearity was less than 40 pm. The results also demonstrate that the interferometer design is capable of subnanometer accuracy and is useful in nanometrology

  6. Friends with benefits, but without the sex: straight women and gay men exchange trustworthy mating advice.

    Science.gov (United States)

    Russell, Eric M; DelPriore, Danielle J; Butterfield, Max E; Hill, Sarah E

    2013-02-09

    Although research has made progress in elucidating the benefits exchanged within same- and opposite-sex friendships formed between heterosexual men and women, it is less clear why straight women and gay men form close relationships with one another. The current experiments begin to address this question by exploring a potential benefit hypothesized to be uniquely available to straight women and gay men in the context of these friendships: trustworthy mating advice. Experiment 1 revealed that straight women perceive mating-relevant advice from a gay man to be more trustworthy than similar advice offered by a straight man or woman. Experiment 2 demonstrated that gay men perceive mating advice offered by a straight woman to be more trustworthy than advice offered by a lesbian woman or another gay man. Overall, the results provide initial experimental evidence that relationships between gay men and straight women may be characterized by a mutual exchange of mating-relevant benefits in the absence of sexual interest or competition.

  7. Friends with Benefits, but without the Sex: Straight Women and Gay Men Exchange Trustworthy Mating Advice

    Directory of Open Access Journals (Sweden)

    Eric M. Russell

    2013-01-01

    Full Text Available Although research has made progress in elucidating the benefits exchanged within same- and opposite-sex friendships formed between heterosexual men and women, it is less clear why straight women and gay men form close relationships with one another. The current experiments begin to address this question by exploring a potential benefit hypothesized to be uniquely available to straight women and gay men in the context of these friendships: trustworthy mating advice. Experiment 1 revealed that straight women perceive mating-relevant advice from a gay man to be more trustworthy than similar advice offered by a straight man or woman. Experiment 2 demonstrated that gay men perceive mating advice offered by a straight woman to be more trustworthy than advice offered by a lesbian woman or another gay man. Overall, the results provide initial experimental evidence that relationships between gay men and straight women may be characterized by a mutual exchange of mating-relevant benefits in the absence of sexual interest or competition.

  8. Straight Ahead in Microgravity

    Science.gov (United States)

    Wood, S. J.; Vanya, R. D.; Clement, G.

    2014-01-01

    This joint ESA-NASA study will address adaptive changes in spatial orientation related to the subjective straight ahead, and the use of a vibrotactile sensory aid to reduce perceptual errors. The study will be conducted before and after long-duration expeditions to the International Space Station (ISS) to examine how spatial processing of target location is altered following exposure to microgravity. This project specifically addresses the sensorimotor research gap "What are the changes in sensorimotor function over the course of a mission?" Six ISS crewmembers will be requested to participate in three preflight sessions (between 120 and 60 days prior to launch) and then three postflight sessions on R+0/1 day, R+4 +/-2 days, and R+8 +/-2 days. The three specific aims include: (a) fixation of actual and imagined target locations at different distances; (b) directed eye and arm movements along different spatial reference frames; and (c) the vestibulo-ocular reflex during translation motion with fixation targets at different distances. These measures will be compared between upright and tilted conditions. Measures will then be compared with and without a vibrotactile sensory aid that indicates how far one has tilted relative to the straight-ahead direction. The flight study was been approved by the medical review boards and will be implemented in the upcoming Informed Crew Briefings to solicit flight subject participation. Preliminary data has been recorded on 6 subjects during parabolic flight to examine the spatial coding of eye movements during roll tilt relative to perceived orientations while free-floating during the microgravity phase of parabolic flight or during head tilt in normal gravity. Binocular videographic recordings obtained in darkness allowed us to quantify the mean deviations in gaze trajectories along both horizontal and vertical coordinates relative to the aircraft and head orientations. During some parabolas, a vibrotactile sensory aid provided

  9. Stereotactic biopsy of cerebellar lesions: straight versus oblique frame positioning.

    Science.gov (United States)

    Quick-Weller, Johanna; Brawanski, Nina; Dinc, Nazife; Behmanesh, Bedjahn; Kammerer, Sara; Dubinski, Daniel; Seifert, Volker; Marquardt, Gerhard; Weise, Lutz

    2017-10-26

    Biospies of brain lesions with unknown entity are an everyday procedure among many neurosurgical departments. Biopsies can be performed frame-guided or frameless. However, cerebellar lesions are a special entity with a more complex approach. All biopsies in this study were performed stereotactically frame guided. Therefore, only biopsies of cerebellar lesions were included in this study. We compared whether the frame was attached straight versus oblique and we focused on diagnostic yield and complication rate. We evaluated 20 patients who underwent the procedure between 2009 and 2017. Median age was 56.5 years. 12 (60%) Patients showed a left sided lesion, 6 (30%) showed a lesion in the right cerebellum and 2 (10%) patients showed a midline lesion. The stereotactic frame was mounted oblique in 12 (60%) patients and straight in 8 (40%) patients. Postoperative CT scan showed small, clinically silent blood collection in two (10%) of the patients, one (5%) patient showed haemorrhage, which caused a hydrocephalus. He received an external ventricular drain. In both patients with small haemorrhage the frame was positioned straight, while in the patient who showed a larger haemorrhage the frame was mounted oblique. In all patients a final histopathological diagnosis was established. Cerebellar lesions of unknown entity can be accessed transcerebellar either with the stereotactic frame mounted straight or oblique. Also for cerebellar lesions the procedure shows a high diagnostic yield with a low rate of severe complications, which need further treatment.

  10. Cardiorespiratory and metabolic responses during straight and bent knee cycling.

    Science.gov (United States)

    Mandroukas, K; Angelopoulou, N; Christoulas, K; Vrabas, I S

    2000-06-01

    This study examined the influence of knee angle on the cardiorespiratory system loading during submaximal and maximal stationary cycle ergometry. Experimental design and participants: eighteen untrained women (age: 21+/-1.88 years, weight: 57+/-5.75 kg, height: 165+/-5.03 cm, values are mean+/-SD) volunteered as subjects and underwent two-cycle ergometer incremental (Jaeger ER900) tests: 1) straight knee (180 degrees), 2) bent knee (140 degrees). oxygen uptake (VO2), ventilation (VE) and respiratory exchange ratio (RER) were measured continuously during each test using an open circuit spirometry and blood lactate concentration was determined by means of an enzymatic method. Comparing cycling with "straight knee" to cycling with "bent knee" at 50 W, heart rate (HR), V(E) and VO2 were significantly higher (10.6%, 12.5%, 17.8%). At 100 W, blood lactate was significantly lower (10.8%) while VO2 and RER was higher (5.5%, 7.1%). During maximal exercise, the total exercise time was significantly longer (11.2%) and VE, VO2 and HR were significantly higher during cycling with "straight knee" compared to cycling with "bent knee". No significant difference in peak lactate was evident between the two sitting positions. The results of this study indicate that cycling with bent knee requires lower oxygen uptake while pedaling with straight knee is the only way to reach VO2max during cycle testing, since the cardiorespiratory system is fully taxed.

  11. Improving the Lives of Students, Gay and Straight Alike: Gay-Straight Alliances and the Role of School Psychologists

    Science.gov (United States)

    Murphy, Heather Elise

    2012-01-01

    Lesbian, gay, bisexual, and transgender (LGBT) students face many risk factors every day when they enter their school's door. These students often fear for their safety at school, are victimized, have academic difficulties, suffer from issues with their identity development, and are at risk for suicide. School-based Gay-Straight Alliances (GSAs)…

  12. Efficient odd straight medium chain free fatty acid production by metabolically engineered Escherichia coli.

    Science.gov (United States)

    Wu, Hui; San, Ka-Yiu

    2014-11-01

    Free fatty acids (FFAs) can be used as precursors for the production of biofuels or chemicals. Different composition of FFAs will be useful for further modification of the biofuel/biochemical quality. Microbial biosynthesis of even chain FFAs can be achieved by introducing an acyl-acyl carrier protein thioesterase gene into E. coli. In this study, odd straight medium chain FFAs production was investigated by using metabolic engineered E. coli carrying acyl-ACP thioesterase (TE, Ricinus communis), propionyl-CoA synthase (Salmonella enterica), and β-ketoacyl-acyl carrier protein synthase III (four different sources) with supplement of extracellular propionate. By using these metabolically engineered E. coli, significant quantity of C13 and C15 odd straight-chain FFAs could be produced from glucose and propionate. The highest concentration of total odd straight chain FFAs attained was 1205 mg/L by the strain HWK201 (pXZ18, pBHE2), and 85% of the odd straight chain FFAs was C15. However, the highest percentage of odd straight chain FFAs was achieved by the strain HWK201 (pXZ18, pBHE3) of 83.2% at 48 h. This strategy was also applied successfully in strains carrying different TE, such as the medium length acyl-ACP thioesterase gene from Umbellularia californica. C11 and C13 became the major odd straight-chain FFAs. © 2014 Wiley Periodicals, Inc.

  13. Methods of X-ray CT image reconstruction from few projections

    International Nuclear Information System (INIS)

    Wang, H.

    2011-01-01

    To improve the safety (low dose) and the productivity (fast acquisition) of a X-ray CT system, we want to reconstruct a high quality image from a small number of projections. The classical reconstruction algorithms generally fail since the reconstruction procedure is unstable and suffers from artifacts. A new approach based on the recently developed 'Compressed Sensing' (CS) theory assumes that the unknown image is in some sense 'sparse' or 'compressible', and the reconstruction is formulated through a non linear optimization problem (TV/l1 minimization) by enhancing the sparsity. Using the pixel (or voxel in 3D) as basis, to apply the CS framework in CT one usually needs a 'sparsifying' transform, and combines it with the 'X-ray projector' which applies on the pixel image. In this thesis, we have adapted a 'CT-friendly' radial basis of Gaussian family called 'blob' to the CS-CT framework. The blob has better space-frequency localization properties than the pixel, and many operations, such as the X-ray transform, can be evaluated analytically and are highly parallelizable (on GPU platform). Compared to the classical Kaisser-Bessel blob, the new basis has a multi-scale structure: an image is the sum of dilated and translated radial Mexican hat functions. The typical medical objects are compressible under this basis, so the sparse representation system used in the ordinary CS algorithms is no more needed. 2D simulations show that the existing TV and l1 algorithms are more efficient and the reconstructions have better visual quality than the equivalent approach based on the pixel or wavelet basis. The new approach has also been validated on 2D experimental data, where we have observed that in general the number of projections can be reduced to about 50%, without compromising the image quality. (author) [fr

  14. Two-dimensional straightness measurement based on optical knife-edge sensing

    Science.gov (United States)

    Wang, Chen; Zhong, Fenghe; Ellis, Jonathan D.

    2017-09-01

    Straightness error is a parasitic translation along a perpendicular direction to the primary displacement axis of a linear stage. The parasitic translations could be coupled into other primary displacement directions of a multi-axis platform. Hence, its measurement and compensation are critical in precision multi-axis metrology, calibration, and manufacturing. This paper presents a two-dimensional (2D) straightness measurement configuration based on 2D optical knife-edge sensing, which is simple, light-weight, compact, and easy to align. It applies a 2D optical knife-edge to manipulate the diffraction pattern sensed by a quadrant photodetector, whose output voltages could derive 2D straightness errors after a calibration process. This paper analyzes the physical model of the configuration and performs simulations and experiments to study the system sensitivity, measurement nonlinearity, and error sources. The results demonstrate that the proposed configuration has higher sensitivity and insensitive to beam's vibration, compared with the conventional configurations without using the knife-edge, and could achieve ±0.25 μ m within a ±40 μ m measurement range along a 40 mm primary axial motion.

  15. Roundness and straightness measurement of ceramic beam ducts for the 3 GeV-synchrotron

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, Daiji; Kinsho, Michikazu; Kanazawa, Kenichiro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Kubo, Tomio; Sato, Yoshihiro; Saito, Yoshio [High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan)

    2001-12-01

    Large aperture ({phi}200 - {phi}250) cylindrical beam ducts consisting of alumina ceramics will be used in the 3 GeV-synchrotron of High Intensity Proton Accelerator Facility. In particular, bending magnet sections require the large length ({approx}3500 mm) ceramic beam duct connecting several unit ducts whose length is around 500-1000 mm by metallizing and glazing. Therefore it is very important to evaluate roundness and straightness of ceramic ducts because we have to compensate contact area large and have to minimize misalignment of ducts connected. We developed an apparatus for measuring roundness and straightness, and we completed data analysis method using general application software Excel as well as measuring method. Then we have taken data, and have evaluated value of roundness and straightness for the first time about 7 pieces (3 kinds) of ceramic beam duct. At last we have found out that unit ceramic ducts can be made after sintering without polishing with roundness several hundred micron ({mu}m) and straightness around 0.2-1 mm, and that straightness has a tendency to become large as duct length increases as well as roundness increases directly proportional to the maximum oblateness. (author)

  16. Gay-Straight Alliance (GSA) Members' Engagement with Sex Education in Canadian High Schools

    Science.gov (United States)

    Lapointe, Alicia

    2014-01-01

    This paper offers an examination of gay-straight alliance (GSA) members' engagement with sex education, sexual health, and prejudice and discrimination in Canadian public high schools. It explores how five students' (four straight and one gay-identifying) participation in GSAs served as a springboard for learning about and challenging stereotypes;…

  17. Cosmic rays Monte Carlo simulations for the Extreme Energy Events Project

    CERN Document Server

    Abbrescia, M; Aiola, S; Antolini, R; Avanzini, C; Baldini Ferroli, R; Bencivenni, G; Bossini, E; Bressan, E; Chiavassa, A; Cicalò, C; Cifarelli, L; Coccia, E; De Gruttola, D; De Pasquale, S; Di Giovanni, A; D'Incecco, M; Dreucci, M; Fabbri, F L; Frolov, V; Garbini, M; Gemme, G; Gnesi, I; Gustavino, C; Hatzifotiadou, D; La Rocca, P; Li, S; Librizzi, F; Maggiora, A; Massai, M; Miozzi, S; Panareo, M; Paoletti, R; Perasso, L; Pilo, F; Piragino, G; Regano, A; Riggi, F; Righini, G C; Sartorelli, G; Scapparone, E; Scribano, A; Selvi, M; Serci, S; Siddi, E; Spandre, G; Squarcia, S; Taiuti, M; Tosello, F; Votano, L; Williams, M C S; Yánez, G; Zichichi, A; Zuyeuski, R

    2014-01-01

    The Extreme Energy Events Project (EEE Project) is an innovative experiment to study very high energy cosmic rays by means of the detection of the associated air shower muon component. It consists of a network of tracking detectors installed inside Italian High Schools. Each tracking detector, called EEE telescope, is composed of three Multigap Resistive Plate Chambers (MRPCs). At present, 43 telescopes are installed and taking data, opening the way for the detection of far away coincidences over a total area of about 3 × 10 5 km 2 . In this paper we present the Monte Carlo simulations that have been performed to predict the expected coincidence rate between distant EEE telescopes.

  18. Gender, Health Behavior, and Intimate Relationships: Lesbian, Gay, and Straight Contexts

    OpenAIRE

    Reczek, Corinne; Umberson, Debra

    2011-01-01

    Many studies focus on health behavior within the context of intimate ties. However, this literature is limited by reliance on gender socialization theory and a focus on straight (i.e., heterosexual) marriage. We extend this work with an analysis of relationship dynamics around health behavior in 20 long-term straight marriages as well as 15 gay and 15 lesbian long-term cohabiting partnerships in the United States (N=100 individual in-depth interviews). We develop the concept of “health behavi...

  19. Straight lines of neutron scattering in biology: a review of basic controls in SANS and EINS.

    Science.gov (United States)

    Zaccai, Giuseppe

    2012-10-01

    Neutron and X-ray beams in scattering experiments have similar wavelengths and explore the same length scale (~1 Å or 0.1 nm). Data collection and analysis are also broadly similar for both radiation types. There are fundamental differences, however, between the interaction of X-rays and neutrons with matter, which makes them strongly complementary for structural studies in biology. The property of neutrons to distinguish natural abundance hydrogen from its deuterium isotope and the dispersion relation that leads to the energy of ~1 Å neutrons being of the order of thermal energy are well known. They form the basis, respectively, of contrast variation on the one hand and energy-resolved scattering experiments to study macromolecular dynamics-neutron-specific scattering methods on the other. Interestingly, analysis procedures for the structural and dynamics experiments display common aspects that can be expressed as straight-line relationships. These not only act as controls of good sample preparation, but also yield model-free parameters on an absolute scale that provide fundamental information on the structure and dynamics of the system under study.

  20. Characterising CCDs with cosmic rays

    International Nuclear Information System (INIS)

    Fisher-Levine, M.; Nomerotski, A.

    2015-01-01

    The properties of cosmic ray muons make them a useful probe for measuring the properties of thick, fully depleted CCD sensors. The known energy deposition per unit length allows measurement of the gain of the sensor's amplifiers, whilst the straightness of the tracks allows for a crude assessment of the static lateral electric fields at the sensor's edges. The small volume in which the muons deposit their energy allows measurement of the contribution to the PSF from the diffusion of charge as it drifts across the sensor. In this work we present a validation of the cosmic ray gain measurement technique by comparing with radioisotope gain measurments, and calculate the charge diffusion coefficient for prototype LSST sensors

  1. Preliminary estimates of dose and residual activation of selected components in ring collimation straight of the SNS

    International Nuclear Information System (INIS)

    Ludewig, H.; Catalan-Lasheras, N.; Simos, N.; Walker, J.; Mallen, A.; Wei, J.; Todosow, M.

    2000-01-01

    The highest doses to components in the SNS ring are expected to be to those located in the collimation straight section. In this paper the authors present estimated doses to magnets and cable located between collimators. In addition the buildup of relatively long half-life radioactive isotopes is estimated, following machine operation and shutdown. Finally, the potential dose to operators approaching the machine following operation and shutdown for four hours is made. The results indicate that selected components might require replacement after several years of full power operation. In addition, the reflection of gamma-rays from the tunnel walls contribute a non-negligible amount to the dose of an operator in the tunnel following machine shutdown

  2. Synthesis method based on solution regions for planar four bar straight line linkages

    International Nuclear Information System (INIS)

    Lai Rong, Yin; Cong, Mao; Jian you, Han; Tong, Yang; Juan, Huang

    2012-01-01

    An analytical method for synthesizing and selecting desired four-bar straight line mechanisms based on solution regions is presented. Given two fixed pivots, the point position and direction of the target straight line, an infinite number of mechanism solutions can be produced by employing this method, both in the general case and all three special cases. Unifying the straight line direction and the displacement from the given point to the instant center into the same form with different angles as parameters, infinite mechanism solutions can be expressed with different solution region charts. The mechanism property graphs have been computed to enable the designers to find out the involved mechanism information more intuitively and avoid aimlessness in selecting optimal mechanisms

  3. Magnesium plasma immersion ion implantation in a large straight magnetic duct

    International Nuclear Information System (INIS)

    Tan, Ing Hwie; Ueda, Mario; Dallaqua, Renato S; Rossi, Jose O; Beloto, Antonio F; Abramof, Eduardo; Inoue, Y; Takai, Osamu

    2002-01-01

    Magnesium ions were implanted on silicon wafers using a vacuum arc plasma system with a straight 1 m long magnetic duct, 0.22 m in diameter. Good macroparticle filtering was obtained in samples positioned facing the plasma stream and complete filtering was achieved in samples with surfaces parallel to the plasma stream and magnetic field. Deposition is also minimized by placing sample surfaces parallel to the plasma stream. High resolution x-ray diffraction rocking curves of implanted samples show that the changes in lattice constant are due to compressive strain, and the distortion is larger for higher voltages. Without magnetic field the implantation was a few hundred angstroms deep, as expected, but with magnetic field the depth profile was surprisingly extended to over 0.1 μm, a fact for which we do not yet have a convincing explanation, but could be related to radiation enhanced segregation. The presence of a magnetic field increases substantially the retained implantation dose due to the increase in plasma density by two orders of magnitude

  4. The European X-ray Free Electron Laser Project at DESY

    CERN Document Server

    Schwarz, Andreas

    2004-01-01

    On February 5, 2003, the German Federal Ministry of Education and Research decided that the X-ray free-electron laser XFEL, proposed by the International TESLA Collaboration, should be realized as a European project and located at DESY/Hamburg. The ministry also announced that in view of the locational advantage, Germany is prepared to cover half of the investment and personnel costs for the XFEL. In the course of the last year work has concentrated on the following areas: setting up of an organizational structure at DESY for the preparation of the project, discussions with potential European partners on several levels, selection of a new site for the XFEL facility and the preparation of the 'plan approval procedure'. The present status of the technical layout of the Linear Accelerator, the SASE Undulator and Photon Beamlines and the experiment stations will be presented.

  5. Straight studs from southern pine veneer cores and cordwood

    Science.gov (United States)

    Peter Koch

    1968-01-01

    An economically feasible system has been developed for converting southern pine veneer cores into straight 8-foot studs (2). Prototype studs - two per core - were 100 percent SPIB stud grade and better.

  6. Particle physics seminar: Muon radiography of volcanoes and the MU-RAY project

    CERN Multimedia

    Université de Genève

    2011-01-01

    UNIVERSITE DE GENEVE Ecole de physique Département de physique nucléaire et corspusculaire 24, Quai Ernest-Ansermet 1211 GENEVE 4 Tél: (022) 379 62 73 Fax: (022) 379 69 92   Wednesday 25  May 2011 PARTICLE PHYSICS SEMINAR at 17.00 hrs – Stückelberg Auditorium Muon radiography of volcanoes and the MU-RAY project Par Prof. Paolo Strolin, Università Federico II and INFN, Napoli Thanks to their penetration power, high energy muons generated in the interactions of cosmic rays with the Earth’s atmosphere offer the possibility to perform “muon radiographies” of geological structures and in particular volcanoes. The principle is similar to that of the imaging of the interior of human body through the observation of the absorption of X rays. Muon radiography has been first applied in 1970 to the search of unknown burial chambers in the Chefren’s pyramid. In the years 2000, the technique has been ...

  7. Calculation of gas Bremsstrahlung power from straight sections of storage ring at SSRF

    International Nuclear Information System (INIS)

    Hua Zhengdong; Xu Xunjiang; Fang Keming; Xu Jiaqiang

    2008-01-01

    The Shanghai Synchrotron Radiation Facility (SSRF) is a third-generation synchrotron radiation light source with 3.5 GeV in energy, which is composed of the linear accelerator, the booster and the storage ring. The storage ring provides 16 standard straight sections of 6.5 m and 4 long straight sections of 12 meters. Gas Bremsstrahlung (GB) produced by the interaction of the stored beam with the residual gas molecules in straight section, which is so intense and has a very small angular that the GB spectra, the GB power and the GB power distribution should be known. The characters of GB are studied by means of Fluka Monte Carlo code. Our result shows agreement with those obtained by the experiential formulae. (authors)

  8. School Climate, Individual Support, or Both? Gay-Straight Alliances and the Mental Health of Sexual Minority Youth

    Science.gov (United States)

    Walls, N. Eugene; Wisneski, Hope; Kane, Sarah

    2013-01-01

    Using a sample of 284 sexual minority youth and young adults, this paper examines the relationships between mental health variables, the absence or presence of a gay-straight alliance, and membership status in a gay-straight alliance. The results suggest that the presence of a gay-straight alliance in a school or college, rather than actual…

  9. A Straight-Talk Survival Guide for Colleges

    Science.gov (United States)

    Facione, Peter A.

    2009-01-01

    Times are very tough. The great majority of colleges are looking at 2009 and 2010 and beyond, in anticipation of the deepest budget cuts in more than a generation. But as bad as the financial situation may be, colleges can survive if they take swift and strong emergency action. It is time for some straight talk, starting with the realization that…

  10. Fluorescence detection of white-beam X-ray absorption anisotropy: towards element-sensitive projections of local atomic structure

    Science.gov (United States)

    Korecki, P.; Tolkiehn, M.; Dąbrowski, K. M.; Novikov, D. V.

    2011-01-01

    Projections of the atomic structure around Nb atoms in a LiNbO3 single crystal were obtained from a white-beam X-ray absorption anisotropy (XAA) pattern detected using Nb K fluorescence. This kind of anisotropy results from the interference of X-rays inside a sample and, owing to the short coherence length of a white beam, is visible only at small angles around interatomic directions. Consequently, the main features of the recorded XAA corresponded to distorted real-space projections of dense-packed atomic planes and atomic rows. A quantitative analysis of XAA was carried out using a wavelet transform and allowed well resolved projections of Nb atoms to be obtained up to distances of 10 Å. The signal of nearest O atoms was detected indirectly by a comparison with model calculations. The measurement of white-beam XAA using characteristic radiation indicates the possibility of obtaining element-sensitive projections of the local atomic structure in more complex samples. PMID:21997909

  11. Investigation into the limitations of straightness interferometers using a multisensor-based error separation method

    Science.gov (United States)

    Weichert, Christoph; Köchert, Paul; Schötka, Eugen; Flügge, Jens; Manske, Eberhard

    2018-06-01

    The uncertainty of a straightness interferometer is independent of the component used to introduce the divergence angle between the two probing beams, and is limited by three main error sources, which are linked to each other: their resolution, the influence of refractive index gradients and the topography of the straightness reflector. To identify the configuration with minimal uncertainties under laboratory conditions, a fully fibre-coupled heterodyne interferometer was successively equipped with three different wedge prisms, resulting in three different divergence angles (4°, 8° and 20°). To separate the error sources an independent reference with a smaller reproducibility is needed. Therefore, the straightness measurement capability of the Nanometer Comparator, based on a multisensor error separation method, was improved to provide measurements with a reproducibility of 0.2 nm. The comparison results revealed that the influence of the refractive index gradients of air did not increase with interspaces between the probing beams of more than 11.3 mm. Therefore, over a movement range of 220 mm, the lowest uncertainty was achieved with the largest divergence angle. The dominant uncertainty contribution arose from the mirror topography, which was additionally determined with a Fizeau interferometer. The measured topography agreed within  ±1.3 nm with the systematic deviations revealed in the straightness comparison, resulting in an uncertainty contribution of 2.6 nm for the straightness interferometer.

  12. 49 CFR 238.119 - Rim-stamped straight-plate wheels.

    Science.gov (United States)

    2010-10-01

    ... input to the wheel during braking. (b) A rim-stamped straight-plate wheel shall not be used as a... that is periodically tread-braked for a short duration by automatic circuitry for the sole purpose of...

  13. 3D Fourier synthesis of a new X-ray picture identical in projection to a previous picture

    International Nuclear Information System (INIS)

    Carlsson, P.E.

    1993-01-01

    A central problem in diagnostic radiology is to compare a new X-ray picture with a previous picture and from this comparison be able to decide if anatomical changes have occurred in the patient or not. It is of primary interest that these pictures are identical in projection. If not it is difficult to decide with confidence if differences between the pictures are due to anatomical changes or differences in their projection geometry. In this thesis we present a non invasive method that makes it possible to find the relative changes in the projection geometry between the exposure of a previous picture and a new picture. The method presented is based on the projection slice theorem (central section theorem). Instead of an elaborate search for a single new picture a pre-planned set of pictures are exposed from a circular orbit above the patient. By using 3D Fourier transform techniques we are able to synthesize a new X-ray picture from this set of pictures that is identical in projection to the previous one. The method has certain limits. Those are as follows: *The X-ray focus position must always be at a fixed distance from the image plane. *The object may only be translated parallel to the image plane and rotated around axes perpendicular to this plane. Under those restrictions, we may treat divergent projection pictures as if they are generated by a parallel projection of a scaled object. The unknown rotation and translation of the object in the previous case are both retrieved in two different procedures and compensated for. Experiments on synthetic data has proved that the method is working even in the presence of severe noise

  14. Setting the Record Straight on "High-Yield" Strategies

    Science.gov (United States)

    Marzano, Robert J.

    2009-01-01

    Widely credited with proposing nine "high-yield" instructional strategies, author Robert J. Marzano sets the record straight about the broader number of strategies identified by the research. He provides a list of 41 strategies and suggests more nuanced ways of using, observing, and evaluating them. (Contains 1 figure.)

  15. Steam cracking of hydrocarbons 3. Straight-run naphtha

    NARCIS (Netherlands)

    Bajus, M.; Vesely, V.; Leclercq, P.A.; Rijks, J.A.

    1980-01-01

    Steam cracking of straight-run naphtha from Romashkino crude oil was investigated in quartz and stainless steel reactors with a relatively large ratio of Inner surface to volume. The experiments were performed at atmospheric pressure at 780-800 OC for starting ratios of steam to naphtha between 0.5

  16. Manufacture of the straight section chambers for the SPring-8 storage ring

    International Nuclear Information System (INIS)

    Watanabe, K.; Saeki, H.; Sakaue, H.; Ohkuma, H.; Be, S.H.; Oishi, M.; Tuchiya, M.; Nishidono, T.

    1995-01-01

    To carry out the performance test of the vacuum system, we manufactured three different straight section chambers prior to the manufacture of the 48 cell full scale vacuum systems. One of three straight section chambers contains only downstream end absorber, while the other two contain a downstream end absorber, upstream end bellows and a photon beam extraction duct. In this paper, the manufacture of these chambers and their assemblies are described in detail. (author). 1 ref., 3 figs., 3 tabs

  17. The Planning of Straight Line Trajectory in Robotics Using Interactive Graphics

    Directory of Open Access Journals (Sweden)

    Kesheng Wang

    1987-07-01

    Full Text Available The planning of straight line trajectory using the interactive computer graphics simulation of robot manipulator movement is discussed. This new approach to straight line motion planning improves the 'bound deviation joint paths' developed by R. M. Taylor (1979. The new approach has three characteristics: (1 linear interpolation in joint space; (2 unequal intervals for interpolating knot points; (3 using interactive computer graphics to assure that the maximum deviation in the whole segment is less than the pre-specified values. The structure and mathematical basis of a computer program developed for this purpose are presented.

  18. Reconstruction of computed tomographic image from a few x-ray projections by means of accelerative gradient method

    International Nuclear Information System (INIS)

    Kobayashi, Fujio; Yamaguchi, Shoichiro

    1982-01-01

    A method of the reconstruction of computed tomographic images was proposed to reduce the exposure dose to X-ray. The method is the small number of X-ray projection method by accelerative gradient method. The procedures of computation are described. The algorithm of these procedures is simple, the convergence of the computation is fast, and the required memory capacity is small. Numerical simulation was carried out to conform the validity of this method. A sample of simple shape was considered, projection data were given, and the images were reconstructed from 6 views. Good results were obtained, and the method is considered to be useful. (Kato, T.)

  19. FIXTURING DEVICE FOR DRILLING A STRAIGHT SHAFT

    Directory of Open Access Journals (Sweden)

    SUSAC, Florin

    2017-05-01

    Full Text Available The paper presents a fixturing device used for machining by drilling a straight shaft. The shaft was manufactured on EMCO CONCEPT TURN 55 CNC. The blank used was a bar with circular cross-section. The orientation and fixing scheme of the part and the orientation elements for fixturing device are presented as they were drawn in Autodesk Inventor and AutoCAD software.

  20. Localizing intracavitary brachytherapy applicators from cone-beam CT x-ray projections via a novel iterative forward projection matching algorithm

    International Nuclear Information System (INIS)

    Pokhrel, Damodar; Murphy, Martin J.; Todor, Dorin A.; Weiss, Elisabeth; Williamson, Jeffrey F.

    2011-01-01

    Purpose: To present a novel method for reconstructing the 3D pose (position and orientation) of radio-opaque applicators of known but arbitrary shape from a small set of 2D x-ray projections in support of intraoperative brachytherapy planning. Methods: The generalized iterative forward projection matching (gIFPM) algorithm finds the six degree-of-freedom pose of an arbitrary rigid object by minimizing the sum-of-squared-intensity differences (SSQD) between the computed and experimentally acquired autosegmented projection of the objects. Starting with an initial estimate of the object's pose, gIFPM iteratively refines the pose parameters (3D position and three Euler angles) until the SSQD converges. The object, here specialized to a Fletcher-Weeks intracavitary brachytherapy (ICB) applicator, is represented by a fine mesh of discrete points derived from complex combinatorial geometric models of the actual applicators. Three pairs of computed and measured projection images with known imaging geometry are used. Projection images of an intrauterine tandem and colpostats were acquired from an ACUITY cone-beam CT digital simulator. An image postprocessing step was performed to create blurred binary applicators only images. To quantify gIFPM accuracy, the reconstructed 3D pose of the applicator model was forward projected and overlaid with the measured images and empirically calculated the nearest-neighbor applicator positional difference for each image pair. Results: In the numerical simulations, the tandem and colpostats positions (x,y,z) and orientations (α,β,γ) were estimated with accuracies of 0.6 mm and 2 deg., respectively. For experimentally acquired images of actual applicators, the residual 2D registration error was less than 1.8 mm for each image pair, corresponding to about 1 mm positioning accuracy at isocenter, with a total computation time of less than 1.5 min on a 1 GHz processor. Conclusions: This work describes a novel, accurate, fast, and completely

  1. Localizing intracavitary brachytherapy applicators from cone-beam CT x-ray projections via a novel iterative forward projection matching algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Pokhrel, Damodar; Murphy, Martin J.; Todor, Dorin A.; Weiss, Elisabeth; Williamson, Jeffrey F. [Department of Radiation Oncology, School of Medicine, Virginia Commonwealth University, Richmond, Virginia 23298 (United States)

    2011-02-15

    Purpose: To present a novel method for reconstructing the 3D pose (position and orientation) of radio-opaque applicators of known but arbitrary shape from a small set of 2D x-ray projections in support of intraoperative brachytherapy planning. Methods: The generalized iterative forward projection matching (gIFPM) algorithm finds the six degree-of-freedom pose of an arbitrary rigid object by minimizing the sum-of-squared-intensity differences (SSQD) between the computed and experimentally acquired autosegmented projection of the objects. Starting with an initial estimate of the object's pose, gIFPM iteratively refines the pose parameters (3D position and three Euler angles) until the SSQD converges. The object, here specialized to a Fletcher-Weeks intracavitary brachytherapy (ICB) applicator, is represented by a fine mesh of discrete points derived from complex combinatorial geometric models of the actual applicators. Three pairs of computed and measured projection images with known imaging geometry are used. Projection images of an intrauterine tandem and colpostats were acquired from an ACUITY cone-beam CT digital simulator. An image postprocessing step was performed to create blurred binary applicators only images. To quantify gIFPM accuracy, the reconstructed 3D pose of the applicator model was forward projected and overlaid with the measured images and empirically calculated the nearest-neighbor applicator positional difference for each image pair. Results: In the numerical simulations, the tandem and colpostats positions (x,y,z) and orientations ({alpha},{beta},{gamma}) were estimated with accuracies of 0.6 mm and 2 deg., respectively. For experimentally acquired images of actual applicators, the residual 2D registration error was less than 1.8 mm for each image pair, corresponding to about 1 mm positioning accuracy at isocenter, with a total computation time of less than 1.5 min on a 1 GHz processor. Conclusions: This work describes a novel, accurate

  2. Localizing intracavitary brachytherapy applicators from cone-beam CT x-ray projections via a novel iterative forward projection matching algorithm.

    Science.gov (United States)

    Pokhrel, Damodar; Murphy, Martin J; Todor, Dorin A; Weiss, Elisabeth; Williamson, Jeffrey F

    2011-02-01

    To present a novel method for reconstructing the 3D pose (position and orientation) of radio-opaque applicators of known but arbitrary shape from a small set of 2D x-ray projections in support of intraoperative brachytherapy planning. The generalized iterative forward projection matching (gIFPM) algorithm finds the six degree-of-freedom pose of an arbitrary rigid object by minimizing the sum-of-squared-intensity differences (SSQD) between the computed and experimentally acquired autosegmented projection of the objects. Starting with an initial estimate of the object's pose, gIFPM iteratively refines the pose parameters (3D position and three Euler angles) until the SSQD converges. The object, here specialized to a Fletcher-Weeks intracavitary brachytherapy (ICB) applicator, is represented by a fine mesh of discrete points derived from complex combinatorial geometric models of the actual applicators. Three pairs of computed and measured projection images with known imaging geometry are used. Projection images of an intrauterine tandem and colpostats were acquired from an ACUITY cone-beam CT digital simulator. An image postprocessing step was performed to create blurred binary applicators only images. To quantify gIFPM accuracy, the reconstructed 3D pose of the applicator model was forward projected and overlaid with the measured images and empirically calculated the nearest-neighbor applicator positional difference for each image pair. In the numerical simulations, the tandem and colpostats positions (x,y,z) and orientations (alpha, beta, gamma) were estimated with accuracies of 0.6 mm and 2 degrees, respectively. For experimentally acquired images of actual applicators, the residual 2D registration error was less than 1.8 mm for each image pair, corresponding to about 1 mm positioning accuracy at isocenter, with a total computation time of less than 1.5 min on a 1 GHz processor. This work describes a novel, accurate, fast, and completely automatic method to

  3. "Appearance potent"? A content analysis of UK gay and straight men's magazines.

    Science.gov (United States)

    Jankowski, Glen S; Fawkner, Helen; Slater, Amy; Tiggemann, Marika

    2014-09-01

    With little actual appraisal, a more 'appearance potent' (i.e., a reverence for appearance ideals) subculture has been used to explain gay men's greater body dissatisfaction in comparison to straight men's. This study sought to assess the respective appearance potency of each subculture by a content analysis of 32 issues of the most read gay (Attitude, Gay Times) and straight men's magazines (Men's Health, FHM) in the UK. Images of men and women were coded for their physical characteristics, objectification and nudity, as were the number of appearance adverts and articles. The gay men's magazines featured more images of men that were appearance ideal, nude and sexualized than the straight men's magazines. The converse was true for the images of women and appearance adverts. Although more research is needed to understand the effect of this content on the viewer, the findings are consistent with a more appearance potent gay male subculture. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  4. Standing down Straight: Jump Rhythm Technique's Rhythm-Driven, Community-Directed Approach to Dance Education

    Science.gov (United States)

    Siegenfeld, Billy

    2009-01-01

    "Standing down straight" means to stand on two feet with both stability and relaxation. Using standing down straight as the foundation of class work, Jump Rhythm Technique offers a fresh alternative to conventional systems of dance study. It bases its pedagogy on three behaviors: grounding the body so that it can move with power and efficiency,…

  5. Modeling plasma flow in straight and curved solenoids

    International Nuclear Information System (INIS)

    Boercker, D.B.; Sanders, D.M.; Storer, J.; Falabella, S.

    1991-01-01

    The ''flux-tube'' model originated by Morozov is a very simple and numerically efficient method for simulating ion motion in plasma filters. In order to test its utility as a design tool, we compare the predictions of the model to recent experimental measurements of plasma flow in both straight and curved solenoids

  6. Straight chiropractic philosophy as a barrier to Medicare compliance: a discussion of 5 incongruent issues.

    Science.gov (United States)

    Seaman, David R; Soltys, Jonathan R

    2013-12-01

    The purpose of this commentary is to discuss potential 5 factors within straight chiropractic philosophy and practice that may prevent Medicare compliance. The national Medicare Benefit Policy Manual and the Florida Local Coverage Determination were reviewed to identify documentation and conceptual issues regarding chiropractic practice. Five Medicare positions were contrasted with tenets of straight chiropractic philosophy. Based on Medicare's documentation requirements, Medicare defines subluxation and chiropractic practice from the perspective of treating spinal pain and related functional disability. In contrast, traditional straight chiropractic philosophy is not based on the treatment of spinal pain and disability or other symptomatic presentations. In this context, 5 potential areas of conflict are discussed. The Medicare version of chiropractic practice is not consistent with traditional straight chiropractic philosophy, which may play a role in preventing Medicare compliance. The chiropractic profession may need to consider the fashion in which "philosophy" as it relates to technique and practice is presented to students and doctors to facilitate compliance with the documentation requirements of Medicare.

  7. Imaging Local Polarization in Ferroelectric Thin Films by Coherent X-Ray Bragg Projection Ptychography

    Science.gov (United States)

    Hruszkewycz, S. O.; Highland, M. J.; Holt, M. V.; Kim, Dongjin; Folkman, C. M.; Thompson, Carol; Tripathi, A.; Stephenson, G. B.; Hong, Seungbum; Fuoss, P. H.

    2013-04-01

    We used x-ray Bragg projection ptychography (BPP) to map spatial variations of ferroelectric polarization in thin film PbTiO3, which exhibited a striped nanoscale domain pattern on a high-miscut (001) SrTiO3 substrate. By converting the reconstructed BPP phase image to picometer-scale ionic displacements in the polar unit cell, a quantitative polarization map was made that was consistent with other characterization. The spatial resolution of 5.7 nm demonstrated here establishes BPP as an important tool for nanoscale ferroelectric domain imaging, especially in complex environments accessible with hard x rays.

  8. Perspectives for the gamma-ray spectroscopy at LNL: the GALILEO project

    International Nuclear Information System (INIS)

    Ur, Calin A

    2012-01-01

    GALILEO is a new 4π high-resolution γ-ray array in which GASP tapered detectors and Gammapool Cluster detectors will be used together. The array will be located at the Laboratori Nazionali di Legnaro and it will make use of the stable beams provided by the Tandem-ALPI-PIAVE accelerator complex and, in the future, of the exotic radioactive ion beams provided by SPES. The project requires the transformation of the original EUROBALL 7-capsules cluster detectors into triple cluster detectors and several R and D activities are ongoing for the development of a triple cluster cryostat and for building the corresponding anti-Compton shields. The development of the front-end, digital sampling, preprocessing and readout electronics is taking advantage of the most recent advances obtained within the AGATA project. A strong physics case was made for the building of the GALILEO array based on Letters of Intent submitted by several research groups from all over the world. In the present paper a brief summary of the status and the perspectives of the GALILEO project is given.

  9. A method for volumetric imaging in radiotherapy using single x-ray projection

    International Nuclear Information System (INIS)

    Xu, Yuan; Yan, Hao; Ouyang, Luo; Wang, Jing; Jiang, Steve B.; Jia, Xun; Zhou, Linghong; Cervino, Laura

    2015-01-01

    Purpose: It is an intriguing problem to generate an instantaneous volumetric image based on the corresponding x-ray projection. The purpose of this study is to develop a new method to achieve this goal via a sparse learning approach. Methods: To extract motion information hidden in projection images, the authors partitioned a projection image into small rectangular patches. The authors utilized a sparse learning method to automatically select patches that have a high correlation with principal component analysis (PCA) coefficients of a lung motion model. A model that maps the patch intensity to the PCA coefficients was built along with the patch selection process. Based on this model, a measured projection can be used to predict the PCA coefficients, which are then further used to generate a motion vector field and hence a volumetric image. The authors have also proposed an intensity baseline correction method based on the partitioned projection, in which the first and the second moments of pixel intensities at a patch in a simulated projection image are matched with those in a measured one via a linear transformation. The proposed method has been validated in both simulated data and real phantom data. Results: The algorithm is able to identify patches that contain relevant motion information such as the diaphragm region. It is found that an intensity baseline correction step is important to remove the systematic error in the motion prediction. For the simulation case, the sparse learning model reduced the prediction error for the first PCA coefficient to 5%, compared to the 10% error when sparse learning was not used, and the 95th percentile error for the predicted motion vector was reduced from 2.40 to 0.92 mm. In the phantom case with a regular tumor motion, the predicted tumor trajectory was successfully reconstructed with a 0.82 mm error for tumor center localization compared to a 1.66 mm error without using the sparse learning method. When the tumor motion

  10. [The peculiar morphological features of the imprints of straight and wavy head hair dirtied with blood].

    Science.gov (United States)

    Leonova, E N; Nagornov, M N; Prokhorenko, A S

    2018-01-01

    The objective of the present study was to elucidate the specific morphological features of the imprints of blood-soaked straight and wavy head hair. The contact imprints of straight and wavy head hair dirtied with blood were obtained experimentally. The imprints of straight hair were shown to exhibit the elements in the form of the rectilinear and bow-shaped slightly bent stripes. The imprints of wavy hair were shaped as the arches, waves, circles, and a large number of various small elements, such as dashes and commas.

  11. Subjective Straight Ahead Orientation in Microgravity

    Science.gov (United States)

    Clement, G.; Reschke, M. F.; Wood, S. J.

    2015-01-01

    This joint ESA NASA study will address adaptive changes in spatial orientation related to the subjective straight ahead and the use of a vibrotactile sensory aid to reduce perceptual errors. The study will be conducted before and after long-duration expeditions to the International Space Station (ISS) to examine how spatial processing of target location is altered following exposure to microgravity. This study addresses the sensorimotor research gap to "determine the changes in sensorimotor function over the course of a mission and during recovery after landing."

  12. The MU-RAY project: detector technology and first data from Mt. Vesuvius

    International Nuclear Information System (INIS)

    Ambrosino, F; Cimmino, L; Garufi, F; Lauria, A; Masone, V; Anastasio, A; Basta, D; Energico, S; Bonechi, L; Brianzi, M; Ciaranfi, R; Bross, A; Callier, S; Taille, C de La; Caputo, A; D'Auria, L; Giudicepietro, F; Macedonio, G; Martini, M; D'Alessandro, R

    2014-01-01

    Muon Radiography allows to map the density of a volcanic cone. It is based on the measurement of the attenuation of the flux of muons present in the cosmic radiation on the ground. The MU-RAY project has developed an innovative detector designed for the muon radiography. The main features are the low electric power consumption, robustness and transportability, good spatial resolution and muon time of flight measurement. A 1 m 2 detector prototype has been constructed. and collected data at Mt. Vesuvius for approximately 1 month in spring 2013. A second campaign of measurement has been performed at the Puy de Dôme, France, in the last four months of 2013. In this article the principles of muon radiography, the MU-RAY detector and the first results from the collected data will be described

  13. Study on an Undershot Cross-Flow Water Turbine with Straight Blades

    Directory of Open Access Journals (Sweden)

    Yasuyuki Nishi

    2015-01-01

    Full Text Available Small-scale hydroelectric power generation has recently attracted considerable attention. The authors previously proposed an undershot cross-flow water turbine with a very low head suitable for application to open channels. The water turbine was of a cross-flow type and could be used in open channels with the undershot method, remarkably simplifying its design by eliminating guide vanes and the casing. The water turbine was fitted with curved blades (such as the runners of a typical cross-flow water turbine installed in tube channels. However, there was ambiguity as to how the blades’ shape influenced the turbine’s performance and flow field. To resolve this issue, the present study applies straight blades to an undershot cross-flow water turbine and examines the performance and flow field via experiments and numerical analyses. Results reveal that the output power and the turbine efficiency of the Straight Blades runner were greater than those of the Curved Blades runner regardless of the rotational speed. Compared with the Curved Blades runner, the output power and the turbine efficiency of the Straight Blades runner were improved by about 31.7% and about 67.1%, respectively.

  14. Radiographic comparison of apical root resorption after orthodontic treatment between bidimensional and Roth straight-wire techniques.

    Science.gov (United States)

    Zawawi, Khalid H; Malki, Ghadah A

    2014-10-01

    The aim of this study was to compare the amount of root resorption after orthodontic treatment between the bidimensional and the Roth straight-wire techniques. Another objective was to compare the amount of root resorption in the whole sample studied and record the prevalence of root resorption. The sample consisted of 40 patients (age ranged between 11 and 18 years) with Angle Class II division 1 malocclusions, treated nonextraction. Twenty patients were treated with bidimensional technique and 20 with a 0.018-inch Roth straight-wire technique. Root lengths of the maxillary incisors were measured on pre- and post-treatment periapical radiographs. The results demonstrated that the bidimensional and Roth straight-wire groups showed significant root resorption after treatment, 1.11 (0.17) and 0.86 (0.05), respectively, P root shortening between the bidimensional and Roth straight-wire groups, there was no significant difference between the mean change from pre- to post-treatment between bidimensional group (mean = 1.00 ± 1.34) and Roth straight-wire group (mean = 0.88 ± 0.86), P = 0.63. Considering the whole sample, there was no root resoprtion in 32.5% of the analysed teeth. There was only mild resorption in 56.2%, moderate in 8.8% and severe in only 2.5% of the teeth. Treatment with the bidimensional technique did not produce an increase in the amount of root resorption. The prevalence and amount of root resorption was similar between bidimensional and Roth straight-wire techniques.

  15. Cubic systems with invariant affine straight lines of total parallel multiplicity seven

    Directory of Open Access Journals (Sweden)

    Alexandru Suba

    2013-12-01

    Full Text Available In this article, we study the planar cubic differential systems with invariant affine straight lines of total parallel multiplicity seven. We classify these system according to their geometric properties encoded in the configurations of invariant straight lines. We show that there are only 17 different topological phase portraits in the Poincar\\'e disc associated to this family of cubic systems up to a reversal of the sense of their orbits, and we provide representatives of every class modulo an affine change of variables and rescaling of the time variable.

  16. Electron track reconstruction and improved modulation for photoelectric X-ray polarimetry

    Energy Technology Data Exchange (ETDEWEB)

    Li, Tenglin [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education (China); Zeng, Ming, E-mail: zengming@tsinghua.edu.cn [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education (China); Feng, Hua [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education (China); Center for Astrophysics, Tsinghua University, Beijing 100084 (China); Cang, Jirong [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education (China); Li, Hong; Zhang, Heng [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education (China); Center for Astrophysics, Tsinghua University, Beijing 100084 (China); Zeng, Zhi; Cheng, Jianping; Ma, Hao; Liu, Yinong [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education (China)

    2017-06-21

    The key to photoelectric X-ray polarimetry is the determination of the emission direction of photoelectrons. Because of the low mass of an electron, the ionisation trajectory is not straight and the useful information needed for polarimetry is stored mostly in the initial part of the track where less energy is deposited. We present a new algorithm, based on the shortest path problem in graph theory, to reconstruct the 2D electron track from the measured image that is blurred due to transversal diffusion along drift and multiplication in the gas chamber. Compared with previous methods based on moment analysis, this algorithm allows us to identify the photoelectric interaction point more accurately and precisely for complicated tracks resulting from high energy photons or low pressure chambers. This leads to a better position resolution and a higher degree of modulation toward high energy X-rays. The new algorithm is justified using simulations and measurements with the gas pixel detector (GPD), and it should also work for other polarimetric techniques such as a time projection chamber (TPC). As the improvement is restricted in the high energy band, this new algorithm shows limited improvement for the sensitivity of GPD polarimeters, but it may have a larger potential for low-pressure TPC polarimeters.

  17. Swan-neck versus straight peritoneal dialysis catheter: Long-term effect on patient and method survival.

    Science.gov (United States)

    Filiopoulos, V; Biblaki, D; Takouli, L; Dounavis, A; Hadjiyannakos, D; Vlassopoulos, D

    2016-09-01

    Peritoneal dialysis (PD) is limited mainly by a higher technique failure rate as compared to hemodialysis (HD), catheter malfunction being an important reason. Intra- and extra-peritoneal catheter configuration may be associated with mechanical and infectious complications affecting method survival. We report our experience with two extra-peritoneal catheter configurations: the straight and the swan-neck (SN) catheters. A total of 85 consecutive patients, 58 males and 27 females were included in the study. Among them, 26 were diabetics; 52 were treated with automated PD (APD) and 33 with continuous ambulatory PD (CAPD). Straight catheters were used in 38 patients (straight group) and SN catheters in 47 patients (SN group). Straight catheters were mostly used in the first 6-year period while SN catheters in the last 6-year period. The baseline demographics were similar between the two groups. A significantly higher frequency of APD use was observed in SN group. Technique survival was better with SN versus straight (log-rank test, P = 0.01) while patient and catheter survival were similar. A better technique survival is noted in our group of patients with SN catheters. An additional factor could be the significantly higher frequency of APD use in this group. Changes in PD solutions' composition could also contribute to improvement in technique survival. The outcome for patients and catheter types used was similar.

  18. First straw straightness measurements on a 4-plane end-cap ATLAS TRT wheel

    CERN Document Server

    Lucotte, A; Mitsou, V A; Mouraviev, S V; Nadtochy, A

    2001-01-01

    This document reports the first results and their interpretation of the straw straightness measurements that have been performed on the first 4-plane end-cap prototype of the ATLAS TRT. Section 2 presents the experimental setup used for the measurements, as well as a review of the data sample used to perform this study. It also provides a description of the method used to assess straw straightness, which is based on the measurements of the maximal gas gain deviation (``straw eccentricity'') seen along the straw. Section 3 reports the results of straw straightness for the 4-plane module, including corrections due to the gas flow. The effect of energy resolution degradation is also explained and results in terms of wire offset are reported. In Section 4, the straw bending due to an applied lateral deformation is measured, and finally Section 5 reviews the conclusions.

  19. Tetrahedron equations and the relativistic S-matrix of straight-strings in 2+1-dimensions

    International Nuclear Information System (INIS)

    Zamolodchikov, A.B.

    1981-01-01

    The quantum S-matrix theory of straight-strings (infinite one-dimensioanl objects like straight domain walls) in 2 + 1-dimensions is considered. The S-matrix is supposed to be purely elastic and factorized. The tetrahedron equations (which are the factorization conditions) are investigated for the special two-colour model. The relativistic three-string S-matrix, which apparently satisfies this tetrahedron equation, is proposed. (orig.)

  20. Polygonal Area of Prosthesis Support with Straight and Tilted Dental Implants in Edentulous Maxillae.

    Science.gov (United States)

    Wentaschek, Stefan; Lehmann, Karl Martin; Scheller, Herbert; Weibrich, Gernot; Behneke, Nikolaus

    2016-01-01

    The aim of this in vitro study was to assess the increase in the polygonal area of implant-retained prosthesis supports in edentulous maxillae with the use of tilted distal implants compared with the use of straight distal implants, using a variety of implant lengths. A total of 25 DICOM datasets of atrophic edentulous maxillae were provided. Bone augmentations in the molar region had to be avoided. Two straight reference implants were virtually inserted in the anterior region. Two additional implants were placed far distally on both sides (4 groups: [1] straight, 12-mm length; [2] straight, 10 mm; [3] straight, 8 mm; [4] tilted, 12-16 mm). The resulting implant-supported polygon was measured for each of the 4 groups using three-dimensional planning software. The mean sagittal depth of the supported polygon in Group 1 was 9.9 mm (standard deviation [SD] 4.4) on the right and 10.2 mm (SD 4.4) on the left, and it was 33.7 mm (SD 5.8) in width. For Group 2, the mean sagittal depth was 11.5 mm (SD 5.0) on the right and 11.9 mm (SD 4.7) on the left, and the width was 35.2 mm (SD 5.6). The measurements for Group 3 were 13.8 mm (SD 4.9) deep on the right, 13.8 mm (SD 5.1) deep on the left, and 37.0 mm (SD 5.4) in width. For Group 4, the depth was 15.8 mm (SD 4.9) on the right and 16.4 mm (SD 5.8) on the left, and the width was 39.0 mm (SD 5.1). The area of implant-retained prosthesis support can be enlarged by the use of tilted implants (12 to 16 mm in length, 42 to 45 degrees) compared to the use of straight 8-mm implants (resulting increase: about 15%).

  1. Comparison of Axillary Loop and Straight Grafts Patency and Their Complications for Hemodialylis Access

    Directory of Open Access Journals (Sweden)

    J KHoshnevis

    2011-08-01

    Full Text Available Introduction & Objective: Dialysis vascular access complications are important causes of morbidity in chronic hemodialysis patients. The aim of the present study was a comparison of auxillary loop and atraight grafts patency and its complications for hemodialysis access. Materials & Methods: In this cohort study conducted at Shahid Beheshti Medical University, 58 patients who underwent placement of loop or straight access grafts were included in the study. Demographics, primary and secondary patency rates and complications like thrombosis, infection, bleeding, steal syndrome and other complications were compared in these two groups. The collected data was analyzed by the SPSS statistical software using the chi-square test, t-test, and logistic regression. Results: Thrombosis rates were 51.1% and 53.8% in straight and loop groups respectively (P=0.862, steal syndrome rates were 2.2% and 7.7% in straight and loop groups respectively (P=0.341, psudoanevrism were 11.1% and 23.1% in straight and loop groups respectively (P=0.270, bleeding rates were 4.4% and 0% in straight and loop groups respectively (P=0.439, infection rate were 8.9% and 7.7% in straight and loop groups respectively (P=0.892, and primary patency rate after 1 month were 88.9% and 92.3% respectively (P=0.721, and primary patency rate after 24 month were 31% and 55.5% respectively (P=0.058. Secondary patency rate after 3 month were 75.6% and 92.3% respectively (P=0.189, and secondary patency rate after 24 month were 37.9% and 66.7% respectively (P=0.044. Conclusion: PTFE vascular graft seems to be an appropriate vascular access and is a promising alternative when upper extremity arteriovenous fistulas cannot be constructed. Additionally, there was no significant different between two groups for complications and early patency, but late patency was better in loop group. More study is necessary for final judgment.

  2. Guiding hard x rays with glass polycapillary fiber

    International Nuclear Information System (INIS)

    Xiao, Q.F.; Ponomarev, I.Y.; Kolomitsev, A.I.; Gibson, D.M.; Dilmanian, F.A.; Nachaliel, E.

    1993-01-01

    X rays can be guided through a polycapillary fiber by multiple total reflections from the smooth channel walls of the fiber. Using monochromatic Synchrotron Radiation at energies of 22 and 44 keV, we measured the efficiency of transmission of x rays through polycapillary fibers with channel diameters of about 13 μm. Efficiencies of 57.3% and 54.5% for 22 keV and 44 keV x rays, respectively, were obtained with a 120-mm-long straight polycapillary fiber aligned with the incident beam. These values are close to the open fraction of the fiber, which is about 60%. In addition, transmission efficiency was measured as a function of the tilt angle between the incident beam and the axis of the fiber. We also measured the transmission efficiency as a function of the deflection angle for a 114-mm-long curved polycapillary fiber. The measurements are compared with a ray-tracing simulation

  3. Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method.

    Science.gov (United States)

    Pokhrel, Damodar; Murphy, Martin J; Todor, Dorin A; Weiss, Elisabeth; Williamson, Jeffrey F

    2011-01-01

    To generalize and experimentally validate a novel algorithm for reconstructing the 3D pose (position and orientation) of implanted brachytherapy seeds from a set of a few measured 2D cone-beam CT (CBCT) x-ray projections. The iterative forward projection matching (IFPM) algorithm was generalized to reconstruct the 3D pose, as well as the centroid, of brachytherapy seeds from three to ten measured 2D projections. The gIFPM algorithm finds the set of seed poses that minimizes the sum-of-squared-difference of the pixel-by-pixel intensities between computed and measured autosegmented radiographic projections of the implant. Numerical simulations of clinically realistic brachytherapy seed configurations were performed to demonstrate the proof of principle. An in-house machined brachytherapy phantom, which supports precise specification of seed position and orientation at known values for simulated implant geometries, was used to experimentally validate this algorithm. The phantom was scanned on an ACUITY CBCT digital simulator over a full 660 sinogram projections. Three to ten x-ray images were selected from the full set of CBCT sinogram projections and postprocessed to create binary seed-only images. In the numerical simulations, seed reconstruction position and orientation errors were approximately 0.6 mm and 5 degrees, respectively. The physical phantom measurements demonstrated an absolute positional accuracy of (0.78 +/- 0.57) mm or less. The theta and phi angle errors were found to be (5.7 +/- 4.9) degrees and (6.0 +/- 4.1) degrees, respectively, or less when using three projections; with six projections, results were slightly better. The mean registration error was better than 1 mm/6 degrees compared to the measured seed projections. Each test trial converged in 10-20 iterations with computation time of 12-18 min/iteration on a 1 GHz processor. This work describes a novel, accurate, and completely automatic method for reconstructing seed orientations, as well as

  4. Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method

    Energy Technology Data Exchange (ETDEWEB)

    Pokhrel, Damodar; Murphy, Martin J.; Todor, Dorin A.; Weiss, Elisabeth; Williamson, Jeffrey F. [Department of Radiation Oncology, School of Medicine, Virginia Commonwealth University, Richmond, Virginia 23298 (United States)

    2011-01-15

    Purpose: To generalize and experimentally validate a novel algorithm for reconstructing the 3D pose (position and orientation) of implanted brachytherapy seeds from a set of a few measured 2D cone-beam CT (CBCT) x-ray projections. Methods: The iterative forward projection matching (IFPM) algorithm was generalized to reconstruct the 3D pose, as well as the centroid, of brachytherapy seeds from three to ten measured 2D projections. The gIFPM algorithm finds the set of seed poses that minimizes the sum-of-squared-difference of the pixel-by-pixel intensities between computed and measured autosegmented radiographic projections of the implant. Numerical simulations of clinically realistic brachytherapy seed configurations were performed to demonstrate the proof of principle. An in-house machined brachytherapy phantom, which supports precise specification of seed position and orientation at known values for simulated implant geometries, was used to experimentally validate this algorithm. The phantom was scanned on an ACUITY CBCT digital simulator over a full 660 sinogram projections. Three to ten x-ray images were selected from the full set of CBCT sinogram projections and postprocessed to create binary seed-only images. Results: In the numerical simulations, seed reconstruction position and orientation errors were approximately 0.6 mm and 5 deg., respectively. The physical phantom measurements demonstrated an absolute positional accuracy of (0.78{+-}0.57) mm or less. The {theta} and {phi} angle errors were found to be (5.7{+-}4.9) deg. and (6.0{+-}4.1) deg., respectively, or less when using three projections; with six projections, results were slightly better. The mean registration error was better than 1 mm/6 deg. compared to the measured seed projections. Each test trial converged in 10-20 iterations with computation time of 12-18 min/iteration on a 1 GHz processor. Conclusions: This work describes a novel, accurate, and completely automatic method for reconstructing

  5. Accounting for straight parts effects on elbow's flexibilities in a beam type finite element program

    International Nuclear Information System (INIS)

    Millard, A.

    1983-01-01

    An extension of Von Karman's theory is applied to the calculations of the flexibility factor of a pipe bend terminated by a straight part or a flange. This analysis is restricted to the linear elastic deformation behaviour under in plane bending. Analytical solutions are given for the propagation of ovalization in the elbow and in the straight part. Considering the response of the piping structures, we note that the ovalization of the piping systems are reduced significantly when the straight parts or flanges effects are included. This results are presented in terms of global as well local flexibility factors. They have been compared to numerical results obtained by shell type finite elements method. A complete piping system is analyzed, for economical reasons, with a beam type approach. Also, we show how it is possible to take into account an elbow's flexibilities the straight parts effects by means of flexibilities factors introduced in a beam type elements. We have implemented this method in the computer program TEDEL. In some specific geometrical features, we compare solutions using shell type elements and our formulation. (orig.)

  6. Accounting for straight parts effects on elbow's flexibilities in a beam type finite element program

    International Nuclear Information System (INIS)

    Millard, A.; Vaghi, H.; Ricard, A.

    1983-08-01

    An extension of Von Karman's theory is applied to the calculations of the flexibility factor of a pipe bend terminated by a straight part or a flange. This analysis is restricted to the linear elastic deformation behaviour under in plane bending. Analytical solutions are given for the propagation of ovalization in the elbow and in the straight part. Considering the response of the piping structures, we note that the ovalization of the piping systems are reduced significantly when the straight parts or flanges effects are included. The results are presented in terms of global as well local flexibility factors. They have been compared to numerical results obtained by shell type finite element method. A complete piping system is analyzed, for economical reasons, with a beam type approach. Also, we show how it is possible to take into account on elbow's flexibilities the straight parts effects by means of flexibilities factors introduced in a beam type element. We have implemented this method in the computer program TEDEL. In some specific geometrical features, we compare solutions using shell type elements and our formulation

  7. Three-Axis Ground Reaction Force Distribution during Straight Walking.

    Science.gov (United States)

    Hori, Masataka; Nakai, Akihito; Shimoyama, Isao

    2017-10-24

    We measured the three-axis ground reaction force (GRF) distribution during straight walking. Small three-axis force sensors composed of rubber and sensor chips were fabricated and calibrated. After sensor calibration, 16 force sensors were attached to the left shoe. The three-axis force distribution during straight walking was measured, and the local features of the three-axis force under the sole of the shoe were analyzed. The heel area played a role in receiving the braking force, the base area of the fourth and fifth toes applied little vertical or shear force, the base area of the second and third toes generated a portion of the propulsive force and received a large vertical force, and the base area of the big toe helped move the body's center of mass to the other foot. The results demonstrate that measuring the three-axis GRF distribution is useful for a detailed analysis of bipedal locomotion.

  8. Straight proximal humeral nails are surrounded by more bone stock in comparison to bent nails in an experimental cadaveric study.

    Science.gov (United States)

    Günther, Christian Max; Müller, Peter Ernst; Mutschler, Wolf; Sprecher, Christoph Martin; Milz, Stefan; Braunstein, Volker

    2014-01-01

    In the management of proximal humeral fractures intramedullary implants with bent and straight shape of the proximal part of nail are available. Based on data from previous studies on bone distribution in the humeral head, we hypothesized, that higher densities might exist in the bone stock surrounding straight nails in comparison to their angulated counterparts. With a known positive correlation between bone density and mechanical stability, this could indicate potentially higher rigidity of osteosyntheses done with straight implants. We performed high resolution peripheral quantitative computed tomographies of the potential straight and bent implant bearing regions of 27 cadaveric proximal humeri. The acquired data were analyzed for differences between straight and bent Volumes of Interest as well as intra- and interindividual bone stock distribution. For both straight and bent volumes of interest a considerably declining bone mineral density was found in craniocaudal direction. Mean densities of bent volumes were significantly lower in comparison to their corresponding straight counterparts (p straight shaped implants can be assumed. Since we found a rapid decrease of bone density in cranio-caudal direction, intramedullary implants should be anchored as proximally in the subcortical area as possible to minimize the risk of displacement or cutout. The high correlation between the Volumes of Interest of the corresponding right and left sides could aid in preoperative planning when considering an intra- or extramedullary approach.

  9. The BESSY X-ray microfocus beamline project

    International Nuclear Information System (INIS)

    Erko, A.; Schaefers, F.; Firsov, A.; Peatman, W.B.; Eberhardt, W.; Signorato, R.

    2004-01-01

    The design and construction of a beamline dedicated to X-ray absorption spectroscopy, X-ray fluorescence analysis, X-ray diffraction and X-ray small-angle scattering measurements with micron and submicron spatial resolution in the photon energy range of 1.9-30 keV are reported here. The main feature of the beamline is a combination of all these methods in one experimental station. The source will be a BESSY 7-T wavelength shifter, which is already in operation. Such a wavelength shifter with its continuous spectrum is an optimum source for these experiments. Glass capillaries and the combination of a linear Bragg-Fresnel lens and bimorph mirror were chosen as the special optical components in the beamline. This beamline will open for BESSY users the possibility to perform experiments on the same sample applying a microfocused X-ray beam in combination with advanced experimental methods

  10. The Dugdale solution for two unequal straight cracks weakening

    Indian Academy of Sciences (India)

    A crack arrest model is proposed for an infinite elastic perfectly-plastic plate weakened by two unequal, quasi-static, collinear straight cracks. The Dugdale model solution is obtained for the above problem when the developed plastic zones are subjected to normal cohesive quadratically varying yield point stress. Employing ...

  11. COMPARISON OF POSTOP SIA IN MSICS WITH STRAIGHT INCISION VERSUS FROWN INCISION

    Directory of Open Access Journals (Sweden)

    Shayana Bhumbla

    2017-05-01

    Full Text Available BACKGROUND Surgically-Induced Astigmatism (SIA is one of the commonest causes of poor postoperative vision even after uneventful cataract surgery. Recent advances have led to a newer concept of “refractive cataract surgery.” The aim of the study is to study the comparison of postop SIA in Manual Small Incision Cataract Surgery (MSICS with straight versus frown incision. MATERIALS AND METHODS 50 patients of cataract were divided into 2 groups (25 each - group A underwent MSICS with 6 mm straight incision, group B underwent MSICS with 6 mm frown incision. BCVA, keratometry readings were recorded with auto kerato-refractometer preop, at 1 week, 1 month, 3 months and SIA was calculated with SIA calculator version 2.1, a free software program. RESULTS Mean SIA in group A and B were - 1.14D versus 0.92D at 1 week; 1.26D versus 0.97D at 1 month; 1.29D versus 0.95D at 3 months. The difference was statistically significant at each follow up visit (p<0.05. CONCLUSION Frown incision gives lesser SIA than straight incision in MSICS.

  12. Modeling analyses of two-phase flow instabilities for straight and helical tubes in nuclear power plants

    International Nuclear Information System (INIS)

    Dong, Ruiting; Niu, Fenglei; Zhou, Yuan; Yu, Yu; Guo, Zhangpeng

    2016-01-01

    Highlights: • Two-phase flow instabilities in straight and helical tubes were studied. • The effects of system pressure, mass flux, inlet subcooling on DWO were studied. • The simulation results are consistent with the experimental results. • The RELAP5 results are consistent with frequency domain method results. - Abstract: The effects of system pressure, mass flux and inlet subcooling on two-phase flow instability for the test section consisted of two heated straight channels or two helical channels are studied by means of RELAP5/MOD3.3 and multi-variable frequency domain control theory. The experimental data in two straight channels are used to verify the RELAP5 and multi-variable frequency domain control theory results. The thermal hydraulic behaviors and parametric effects are simulated and compared with the experimental data. The RELAP5 results show that the flow stability increases with the system pressure, mass velocity, and inlet subcooling at high subcoolings. The frequency domain theory presents the same results as those given by the time domain theory (RELAP5). The effects of system pressure, mass velocity and inlet subcooling are simulated to find the difference between the straight and the helical tube flows. The RELAP5 and the multi-variable frequency domain control theory are used in modeling and simulating density wave oscillation to study their advantages and disadvantages in straight and helical tubes.

  13. Modeling analyses of two-phase flow instabilities for straight and helical tubes in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Ruiting [Beijing Key Laboratory of Passive Nuclear Power Safety and Technology, North China Electric Power University, Beijing 102206 (China); Niu, Fenglei, E-mail: niufenglei@ncepu.edu.cn [Beijing Key Laboratory of Passive Nuclear Power Safety and Technology, North China Electric Power University, Beijing 102206 (China); Zhou, Yuan [School of Nuclear Science and Engineering, Shanghai Jiaotong University, Shanghai 200240 (China); Yu, Yu; Guo, Zhangpeng [Beijing Key Laboratory of Passive Nuclear Power Safety and Technology, North China Electric Power University, Beijing 102206 (China)

    2016-10-15

    Highlights: • Two-phase flow instabilities in straight and helical tubes were studied. • The effects of system pressure, mass flux, inlet subcooling on DWO were studied. • The simulation results are consistent with the experimental results. • The RELAP5 results are consistent with frequency domain method results. - Abstract: The effects of system pressure, mass flux and inlet subcooling on two-phase flow instability for the test section consisted of two heated straight channels or two helical channels are studied by means of RELAP5/MOD3.3 and multi-variable frequency domain control theory. The experimental data in two straight channels are used to verify the RELAP5 and multi-variable frequency domain control theory results. The thermal hydraulic behaviors and parametric effects are simulated and compared with the experimental data. The RELAP5 results show that the flow stability increases with the system pressure, mass velocity, and inlet subcooling at high subcoolings. The frequency domain theory presents the same results as those given by the time domain theory (RELAP5). The effects of system pressure, mass velocity and inlet subcooling are simulated to find the difference between the straight and the helical tube flows. The RELAP5 and the multi-variable frequency domain control theory are used in modeling and simulating density wave oscillation to study their advantages and disadvantages in straight and helical tubes.

  14. Radiologic findings of deep seated cerebral arteriovenous malformation with nonvisualization of straight sinus: focused on angiogram

    International Nuclear Information System (INIS)

    Won, Jong Boo; Park, Sung Ho; Hong, Jong Won; Kim, Yoo Kyoung; Shin, Mi Jeong; Baik, Seung Kuk; Choi, Han Yong; Kim, Bong Gi

    1999-01-01

    To analyze the radiologic-especially angiographic-findings of deep seated cerebral arteriovenous malformation(AVM) involving nonvisualized straight sinus. In six patients aged between 15 and 53 years with deep seated cerebral AVM, CT and MR images were retrospectively analyzed with regard to the following features : the presence of straight sinus, the location of AVM, and the occurrence of hemorrhage. Angiograms were analyzed for venous drainage routes of AVM, the appearance of veins, the presence of falcine sinus and venous drainage from normal deep brain parenchyme. In four patients who had undergone intravascular embolization therapy, pre- and post- embolization angiograms were compared. CT and MR images showed neither straight sinus nor thrombosis. AVMs were deeply seated in the brain, and in all cases there was cerebral hemorrhage. Angiograms disclosed that venous drainage of all AVMs occurred via the veins of Galen. In one case, venous flow via the falcine sinus to the superior sagittal sinus was noted, but in others, retrograde flow in the deep venous system was observed. Marked collateral routes followed in response to the obstruction of straight sinus included the basal vein of Rosenthal, the internal occipital, internal cerebral, and cerebellar hemispheric veins (which are Galenic afferents), and the inferior sagittal sinus. In all patients, contralateral routes were partially involved. Venous drainage from normal deep parenchyme through the transcerebral veins to the superficial venous system was noted, and in one case, straight sinus which had been observed on an angiogram five years earlier was no longer present. Angiography offers effective evaluation of the dynamic aspect of venous flow in cases involving deep-seated AVM, and of normal deep parenchyme in cases in which AVM involves nonvisualized straight sinus. Before intravascular treatment of AVM, venous flow must be carefully analyzed

  15. Method of making a low energy gamma ray collimator

    International Nuclear Information System (INIS)

    Muehllehner, Gerd.

    1975-01-01

    Described herein is a method for making a low energy gamma ray collimator which involves corrugating lead foil strips by passing them through pinion wire rollers and gluing corrugated strips between straight strips using an adhesive such as epoxy to build up a honeycomb-like structure. A thin aluminum sheet is glued to both edges of the strips to protect them and to provide a more rigid assembly which may be sawed to a desired shape. (Patent Office Record)

  16. Excessive deformation and failure of straight parts and elbows

    International Nuclear Information System (INIS)

    Touboul, F.; Acker, D.

    1991-01-01

    The design rules for LMFBRs must cover the ranges of loading types and geometries wider than PWR Design Codes. Steam pipework does not differ between two reactor systems, but as far as sodium piping is concerned, usual PWR criteria may not be adequate. The LMFBR sodium piping is operated at high temperature and low pressure level. Moreover, these peculiar loadings require the geometrical characteristics completely different in the fact that the piping must be flexible but need not to be thick. For such piping components, the ultimate behavior depends much on the geometry. 170 experimental results on straight parts and 95 results on elbows were investigated. As for elbows, half of the tests were performed under in-plane closing moment. On the analysis of straight pipes and elbows, the experiments and the proposed expressions for the evaluation of collapse and instability moments are described, respectively. The application of the present study to the design rules and the criteria for various loading conditions are reported. It is difficult to experimentally distinguish between plastic instability and buckling. (K.I.)

  17. Strategies for Selecting Routes through Real-World Environments: Relative Topography, Initial Route Straightness, and Cardinal Direction.

    Directory of Open Access Journals (Sweden)

    Tad T Brunyé

    Full Text Available Previous research has demonstrated that route planners use several reliable strategies for selecting between alternate routes. Strategies include selecting straight rather than winding routes leaving an origin, selecting generally south- rather than north-going routes, and selecting routes that avoid traversal of complex topography. The contribution of this paper is characterizing the relative influence and potential interactions of these strategies. We also examine whether individual differences would predict any strategy reliance. Results showed evidence for independent and additive influences of all three strategies, with a strong influence of topography and initial segment straightness, and relatively weak influence of cardinal direction. Additively, routes were also disproportionately selected when they traversed relatively flat regions, had relatively straight initial segments, and went generally south rather than north. Two individual differences, extraversion and sense of direction, predicted the extent of some effects. Under real-world conditions navigators indeed consider a route's initial straightness, cardinal direction, and topography, but these cues differ in relative influence and vary in their application across individuals.

  18. Youth Empowerment and High School Gay-Straight Alliances

    OpenAIRE

    Russell, Stephen T.; Muraco, Anna; Subramaniam, Aarti; Laub, Carolyn

    2009-01-01

    In the field of positive youth development programs, “empowerment” is used interchangeably with youth activism, leadership, civic participation and self-efficacy. However, few studies have captured what empowerment means to young people in diverse contexts. This article explores how youth define and experience empowerment in youth-led organizations characterized by social justice goals: high school Gay-Straight Alliances (GSAs). Through focus group interviews, fifteen youth leaders of GSAs fr...

  19. X-ray CT core imaging of Oman Drilling Project on D/V CHIKYU

    Science.gov (United States)

    Michibayashi, K.; Okazaki, K.; Leong, J. A. M.; Kelemen, P. B.; Johnson, K. T. M.; Greenberger, R. N.; Manning, C. E.; Harris, M.; de Obeso, J. C.; Abe, N.; Hatakeyama, K.; Ildefonse, B.; Takazawa, E.; Teagle, D. A. H.; Coggon, J. A.

    2017-12-01

    We obtained X-ray computed tomography (X-ray CT) images for all cores (GT1A, GT2A, GT3A and BT1A) in Oman Drilling Project Phase 1 (OmanDP cores), since X-ray CT scanning is a routine measurement of the IODP measurement plan onboard Chikyu, which enables the non-destructive observation of the internal structure of core samples. X-ray CT images provide information about chemical compositions and densities of the cores and is useful for assessing sample locations and the quality of the whole-round samples. The X-ray CT scanner (Discovery CT 750HD, GE Medical Systems) on Chikyu scans and reconstructs the image of a 1.4 m section in 10 minutes and produces a series of scan images, each 0.625 mm thick. The X-ray tube (as an X-ray source) and the X-ray detector are installed inside of the gantry at an opposing position to each other. The core sample is scanned in the gantry with the scanning rate of 20 mm/sec. The distribution of attenuation values mapped to an individual slice comprises the raw data that are used for subsequent image processing. Successive two-dimensional (2-D) slices of 512 x 512 pixels yield a representation of attenuation values in three-dimensional (3-D) voxels of 512 x 512 by 1600 in length. Data generated for each core consist of core-axis-normal planes (XY planes) of X-ray attenuation values with dimensions of 512 × 512 pixels in 9 cm × 9 cm cross-section, meaning at the dimensions of a core section, the resolution is 0.176 mm/pixel. X-ray intensity varies as a function of X-ray path length and the linear attenuation coefficient (LAC) of the target material is a function of the chemical composition and density of the target material. The basic measure of attenuation, or radiodensity, is the CT number given in Hounsfield units (HU). CT numbers of air and water are -1000 and 0, respectively. Our preliminary results show that CT numbers of OmanDP cores are well correlated to gamma ray attenuation density (GRA density) as a function of chemical

  20. New airfoil sections for straight bladed turbine

    Science.gov (United States)

    Boumaza, B.

    1987-07-01

    A theoretical investigation of aerodynamic performance for vertical axis Darrieus wind turbine with new airfoils sections is carried out. The blade section aerodynamics characteristics are determined from turbomachines cascade model. The model is also adapted to the vertical Darrieus turbine for the performance prediction of the machine. In order to choose appropriate value of zero-lift-drag coefficient in calculation, an analytical expression is introduced as function of chord-radius ratio and Reynolds numbers. New airfoils sections are proposed and analyzed for straight-bladed turbine.

  1. New airfoil sections for straight bladed turbine

    International Nuclear Information System (INIS)

    Boumaza, B.

    1987-07-01

    A theoretical investigation of aerodynamic performance for vertical axis Darrieus wind turbine with new airfoils sections is carried out. The blade section aerodynamics characteristics are determined from turbomachines cascade model. The model is also adapted to the vertical Darrieus turbine for the performance prediction of the machine. In order to choose appropriate value of zero-lift-drag coefficient in calculation, an analytical expression is introduced as function of chord-radius ratio and Reynolds numbers. New airfoils sections are proposed and analyzed for straight-bladed turbine

  2. Straight Vegetable Oil as a Diesel Fuel?

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-01-01

    Biodiesel, a renewable fuel produced from animal fats or vegetable oils, is popular among many vehicle owners and fleet managers seeking to reduce emissions and support U.S. energy security. Questions sometimes arise about the viability of fueling vehicles with straight vegetable oil (SVO), or waste oils from cooking and other processes, without intermediate processing. But SVO and waste oils differ from biodiesel (and conventional diesel) in some important ways and are generally not considered acceptable vehicle fuels for large-scale or long-term use.

  3. 27-GAUGE VITRECTOMY WOUND INTEGRITY: A Randomized Pilot Study Comparing Angled Versus Straight Entry in Fluid-Filled Vitrectomized Eyes.

    Science.gov (United States)

    Khan, M Ali; Durrani, Alia K; Hsu, Jason; Regillo, Carl D

    2018-04-01

    To compare clinical outcomes using angled versus straight trocar insertion during 27-gauge pars plana vitrectomy for epiretinal membrane. Pilot randomized controlled trial. Thirty eyes of 30 patients undergoing 27-gauge pars plana vitrectomy with membrane peeling for epiretinal membrane were randomized 1:1 to receive angled or straight trocar insertion. Intraocular pressure (IOP) and postoperative wound-related complications were compared. Fifteen eyes were randomized to each the angled and straight incision groups. No significant difference in phakic status (P = 0.71) or preoperative IOP (15.1 ± 3.4 vs. 14.6 ± 3.0 mmHg, P = 0.67) existed between groups. On postoperative Day 1, eyes in the straight group had lower IOP compared with the angled group (11.8 ± 3.9 vs. 15.3 ± 5.2 mmHg, P = 0.04) and a relative decrease in IOP compared with preoperative values (11.8 ± 3.9 vs. 15.1 ± 3.4 mmHg, P straight group) and serous choroidal detachment (1 eye, angled group). Eyes with straight incisions had transiently lower IOP on postoperative Day 1, possibly suggestive of subclinical wound leak in the very early postoperative period. Overall, rates of hypotony and sclerotomy-related complications were similarly low between wound construction strategies.

  4. Linear Motion Systems. A Modular Approach for Improved Straightness Performance

    NARCIS (Netherlands)

    Nijsse, G.J.P.

    2001-01-01

    This thesis deals with straight motion systems. A modular approach has been applied in order to find ways to improve the performance. The main performance parameters that are considered are position accuracy, repeatability and, to a lesser extent, cost. Because of the increasing requirements to

  5. Insurance-markets Equilibrium with Sequential Non-convex Straight-time and Over-time Labor Supply

    OpenAIRE

    Vasilev, Aleksandar

    2016-01-01

    This note describes the lottery- and insurance-market equilibrium in an economy with non-convex straight-time and overtime employment. In contrast to Hansen and Sargent (1988), the overtime-decision is a sequential one. This requires two separate insurance market to operate, one for straight-time work, and one for overtime. In addi- tion, given that the labor choice for regular and overtime hours is made in succession, the insurance market for overtime needs to open once the insurance market ...

  6. Introduction to 2D and 3D tomographic methods based on straight line propagation: X-ray, emission and ultrasonic tomography

    International Nuclear Information System (INIS)

    Peyrin, F.; Magnin, I.; Garnero, L.

    1996-01-01

    This paper presents the basic principles of computerized tomography (CT), and its evolution towards three dimensional (3D) imaging. Since the modeling of CT reconstruction relies on the Radon transform, its definition and major properties are first recalled. After a brief summary on conventional 2D methods, we present the imaging principles for two modalities appropriated to this modeling: X-Ray and emission tomography. We describe the evolution of the instrumentation for these two techniques, and emphasize the approximations introduced by a modeling using the Radon transform taking into account the physics of the problem. We also describe the principles of ultrasonic tomography systems, and their major differences with the two previous techniques. At last, we formulate the general problematic of 3D image reconstruction from 2D projections. We consider four classes of reconstruction methods corresponding to the classification to the classification chosen for the synthetic presentation of methods, accompanying this paper. (authors)

  7. Modifications in straight wire treatment.

    Science.gov (United States)

    Cardona, Alvin

    2010-01-01

    Orthodontic treatments have been modified with each new generation of clinicians. Today the emphasis is on facial esthetics and healthy temporomandibular joints. With orthopedic treatment, we can develop dental arches to get the necessary space to align the teeth and we can reach adequate function and esthetics, all within relatively good stability. By combining two-phase treatment with low friction fixed orthodontics and super elastic wires we produce light but continuous forces and we can provide better treatment than before. These types of forces cause physiological and functional orthopedic orthodontic reactions. The purpose of this article is to demonstrate our fixed orthopedic and orthodontic approach called "Modified Straight Wire" or "Physiologic Arch Technique." This technique is very successful with our patients because it can exert slow and continuous forces with minimal patient cooperation.

  8. Applications of phase-contrast x-ray imaging to medicine using an x-ray interferometer

    Science.gov (United States)

    Momose, Atsushi; Yoneyama, Akio; Takeda, Tohoru; Itai, Yuji; Tu, Jinhong; Hirano, Keiichi

    1999-10-01

    We are investigating possible medical applications of phase- contrast X-ray imaging using an X-ray interferometer. This paper introduces the strategy of the research project and the present status. The main subject is to broaden the observation area to enable in vivo observation. For this purpose, large X-ray interferometers were developed, and 2.5 cm X 1.5 cm interference patterns were generated using synchrotron X-rays. An improvement of the spatial resolution is also included in the project, and an X-ray interferometer designed for high-resolution phase-contrast X-ray imaging was fabricated and tested. In parallel with the instrumental developments, various soft tissues are observed by phase- contrast X-ray CT to find correspondence between the generated contrast and our histological knowledge. The observation done so far suggests that cancerous tissues are differentiated from normal tissues and that blood can produce phase contrast. Furthermore, this project includes exploring materials that modulate phase contrast for selective imaging.

  9. Comparison of conventional straight and swan-neck straight catheters inserted by percutaneous method for continuous ambulatory peritoneal dialysis: a single-center study.

    Science.gov (United States)

    Singh, Shivendra; Prakash, Jai; Singh, R G; Dole, P K; Pant, Pragya

    2015-10-01

    To evaluate the incidence of mechanical and infectious complications of conventional straight catheter (SC) versus swan-neck straight catheter (SNSC) implanted by percutaneous method. We retrospectively analyzed 45 catheter insertions being done by percutaneous method from January 1, 2011, to May 31, 2014. SC was inserted in 24 patients, and SNSC was inserted in 21 patients. Baseline characteristics for the two groups were similar with respect to age, sex and diabetic nephropathy as the cause for end-stage renal disease. Incidence of mechanical and infectious complications in SNSC group was found to be low as compared to the SC group and was statistically significant (1 in 11.6 patient months vs. 1 in 14.4 patient months, p = 0.02). Catheter migration was found to be the most common mechanical complication (20 %), and peritonitis was found to be the most common infectious complication in conventional SC group (27 episodes in 420 patient months vs. 11 episodes in 333 patient months, p = 0.03). The incidence of exit site and tunnel infection rates revealed no difference between the groups. SNSC insertion by percutaneous method is associated with low mechanical and infectious complications.

  10. Efficacy of Reciproc(®) and Profile(®) Instruments in the Removal of Gutta-Percha from Straight and Curved Root Canals ex Vivo.

    Science.gov (United States)

    Marfisi, Karem; Mercadé, Montserrat; Plotino, Gianluca; Clavel, Tatiana; Duran-Sindreu, Fernando; Roig, Miguel

    2015-01-01

    To compare the efficacy of Reciproc(®) (VDW GmbH) and ProFile(®) (Dentsply Maillefer) instruments at removing gutta-percha from straight and curved root canals ex vivo filled using the cold lateral condensation and GuttaMaster(®) (VDW GmbH) techniques. Forty mesial roots of mandibular molars with two curved canals and 80 single-rooted teeth with straight root canals, a total of 160 root canals, were randomly assigned to eight groups (canals per group = 20) according to filling technique, retreatment instrument and root canal curvature as follows: Group I, cold lateral condensation/ProFile(®)/straight; Group II, cold lateral condensation/ProFile(®)/curved; Group III, cold lateral condensation/Reciproc(®)/straight; Group IV, cold lateral condensation/Reciproc(®)/curved; Group V, GuttaMaster(®)/ProFile(®)/straight; Group VI, GuttaMaster(®)/ProFile(®)/curved; Group VII, GuttaMaster(®)/Reciproc(®)/straight; and Group VIII, GuttaMaster(®)/Reciproc(®)/curved. The following data were recorded: procedural errors, retreatment duration and canal wall cleanliness. Means and standard deviations were calculated and analysed using the Kruskal-Wallis test, one-way analysis of variance and Tukey's test (P straight (P = 0.0001) and curved (P = 0.0003) root canals. Reciproc(®) were statistically more effective than ProFile(®) instruments in removing GuttaMaster(®) from straight root canals (P = 0.021). Regardless of filling technique or retreatment instrument, gutta-percha was removed more rapidly from curved than from straight root canals (P = 0.0001). Neither system completely removed filling material from the root canals. Compared with ProFile(®) instruments, Reciproc(®) instruments removed GuttaMaster(®) filling material from straight and curved root canals more rapidly.

  11. A final report to the Laboratory Directed Research and Development committee on Project 93-ERP-075: ''X-ray laser propagation and coherence: Diagnosing fast-evolving, high-density laser plasmas using X-ray lasers''

    International Nuclear Information System (INIS)

    Wan, A.S.; Cauble, R.; Da Silva, L.B.; Libby, S.B.; Moreno, J.C.

    1996-02-01

    This report summarizes the major accomplishments of this three-year Laboratory Directed Research and Development (LDRD) Exploratory Research Project (ERP) entitled ''X-ray Laser Propagation and Coherence: Diagnosing Fast-evolving, High-density Laser Plasmas Using X-ray Lasers,'' tracking code 93-ERP-075. The most significant accomplishment of this project is the demonstration of a new laser plasma diagnostic: a soft x-ray Mach-Zehnder interferometer using a neonlike yttrium x-ray laser at 155 angstrom as the probe source. Detailed comparisons of absolute two-dimensional electron density profiles obtained from soft x-ray laser interferograms and profiles obtained from radiation hydrodynamics codes, such as LASNEX, will allow us to validate and benchmark complex numerical models used to study the physics of laser-plasma interactions. Thus the development of soft x-ray interferometry technique provides a mechanism to probe the deficiencies of the numerical models and is an important tool for, the high-energy density physics and science-based stockpile stewardship programs. The authors have used the soft x-ray interferometer to study a number of high-density, fast evolving, laser-produced plasmas, such as the dynamics of exploding foils and colliding plasmas. They are pursuing the application of the soft x-ray interferometer to study ICF-relevant plasmas, such as capsules and hohlraums, on the Nova 10-beam facility. They have also studied the development of enhanced-coherence, shorter-pulse-duration, and high-brightness x-ray lasers. The utilization of improved x-ray laser sources can ultimately enable them to obtain three-dimensional holographic images of laser-produced plasmas

  12. Visible/IR light and x-rays in femtosecond synchronism from an x-ray free-electron laser

    International Nuclear Information System (INIS)

    Adams, B. A.; Experimental Facilities Division

    2005-01-01

    A way is proposed to obtain pulses of visible/infrared light in femtosecond synchronism with x-rays from an x-ray free-electron laser (XFEL), using the recently proposed emittance-slicing technique. In an XFEL undulator, only the short section of an electron bunch whose emittance is left unchanged by the slicing will emit intense coherent x-rays in the XFEL undulator. At the same time, the bunch emits highly collimated transition undulator radiation (TUR) into a cone whose opening angle is the reciprocal relativisticity parameter gamma. Due to the variation of the transverse momentum induced by the emittance slicing, the effective number of charges contributing to the TUR varies along the bunch, and is higher in the sliced-out part that emits the coherent x-rays. As with coherent synchrotron radiation (CSR), the TUR is thus coherently enhanced (CTUR) at near-infrared wavelengths. Coming from the same part of the bunch the CTUR and the coherent x-rays are perfectly synchronized to each other. Because both types of radiation are generated in the long straight XFEL undulator, there are no dispersion effects that might induce a timing jitter. With typical XFEL parameters, the energy content of the single optical cycle of near-IR CTUR light is about 100 Nano-Joule, which is quite sufficient for most pump-probe experiments

  13. The Cosmic Ray Observatory Project: Results of a Summer High-School Student, Teacher, University Scientist Partnership Using a Capstone Research Experience

    Science.gov (United States)

    Shell, Duane F.; Snow, Gregory R.; Claes, Daniel R.

    2011-01-01

    This paper reports results from evaluation of the Cosmic Ray Observatory Project (CROP), a student, teacher, scientist partnership to engage high-school students and teachers in school based cosmic ray research. Specifically, this study examined whether an intensive summer workshop experience could effectively prepare teacher-student teams to…

  14. Thin-film-based scintillators for hard x-ray microimaging detectors: the ScinTAX Project

    Science.gov (United States)

    Rack, A.; Cecilia, A.; Douissard, P.-A.; Dupré, K.; Wesemann, V.; Baumbach, T.; Couchaud, M.; Rochet, X.; Riesemeier, H.; Radtke, M.; Martin, T.

    2014-09-01

    The project ScinTAX developed novel thin scintillating films for the application in high performance X-ray imaging and subsequent introduced new X-ray detectors to the market. To achieve this aim lutetium orthosilicate (LSO) scintillators doped with different activators were grown successfully by liquid phase epitaxy. The high density of LSO (7.4 g/cm3), the effective atomic number (65.2) and the high light yield make this scintillator highly applicable for indirect X-ray detection in which the ionizing radiation is converted into visible light and then registered by a digital detector. A modular indirect detection system has been developed to fully exploit the potential of this thin film scintillator for radiographic and tomographic imaging. The system is compatible for high-resolution imaging with moderate dose as well as adaptable to intense high-dose applications where radiation hard microimaging detectors are required. This proceedings article shall review the achieved performances and technical details on this high-resolution detector system which is now available. A selected example application demonstrates the great potential of the optimized detector system for hard X-ray microimaging, i.e. either to improve image contrast due to the availability of efficient thin crystal films or to reduce the dose to the sample.

  15. Column Number Density Expressions Through M = 0 and M = 1 Point Source Plumes Along Any Straight Path

    Science.gov (United States)

    Woronowicz, Michael

    2017-01-01

    Providers of payloads carried aboard the International Space Station must conduct analyses to demonstrate that any planned gaseous venting events generate no more than a certain level of material that may interfere with optical measurements from other experiments or payloads located nearby. This requirement is expressed in terms of a maximum column number density (CND). Depending on the level of rarefaction, such venting may be characterized by effusion for low flow rates, or by a sonic distribution at higher levels. Since the relative locations of other sensitive payloads are often unknown because they may refer to future projects, this requirement becomes a search for the maximum CND along any path.In another application, certain astronomical observations make use of CND to estimate light attenuation from a distant star through gaseous plumes, such as the Fermi Bubbles emanating from the vicinity of the black hole at the center of our Milky Way galaxy, in order to infer the amount of material being expelled via those plumes.This paper presents analytical CND expressions developed for general straight paths based upon a free molecule point source model for steady effusive flow and for a distribution fitted to model flows from a sonic orifice. Among other things, in this Mach number range it is demonstrated that the maximum CND from a distant location occurs along the path parallel to the source plane that intersects the plume axis. For effusive flows this value is exactly twice the CND found along the ray originating from that point of intersection and extending to infinity along the plumes axis. For sonic plumes this ratio is reduced to about 43.

  16. An Inquiry-Based Project Focused on the X-Ray Powder Diffraction Analysis of Common Household Solids

    Science.gov (United States)

    Hulien, Molly L.; Lekse, Jonathan W.; Rosmus, Kimberly A.; Devlin, Kasey P.; Glenn, Jennifer R.; Wisneski, Stephen D.; Wildfong, Peter; Lake, Charles H.; MacNeil, Joseph H.; Aitken, Jennifer A.

    2015-01-01

    While X-ray powder diffraction (XRPD) is a fundamental analytical technique used by solid-state laboratories across a breadth of disciplines, it is still underrepresented in most undergraduate curricula. In this work, we incorporate XRPD analysis into an inquiry-based project that requires students to identify the crystalline component(s) of…

  17. Synthesis and characterization of straight and stacked-sheet AlN nanowires with high purity

    International Nuclear Information System (INIS)

    Lei, M.; Yang, H.; Li, P.G.; Tang, W.H.

    2008-01-01

    Large-scale AlN nanowires with hexagonal crystal structure were synthesized by the direct nitridation method at high temperatures. The experimental results indicate that these single-crystalline AlN nanowires have high purity and consist of straight and stacked-sheet nanowires. It is found that straight AlN nanowire grows along [1, 1, -2, 0] direction, whereas the stacked-sheet nanowire with hexagonal cross section is along [0 0 0 1] direction. It is thought that vapor-solid (VS) mechanism should be responsible for the growth of AlN nanowires

  18. Demographic Trends and Advocacy Experiences of Gay-Straight Alliance Advisors

    Science.gov (United States)

    Graybill, Emily C.; Varjas, Kris; Meyers, Joel; Dever, Bridget V.; Greenberg, Daphne; Roach, Andrew T.; Morillas, Catalina

    2015-01-01

    Using an ecological model, the individual-, school-, and sociocultural-level characteristics that affect gay-straight alliance (GSA) advisors were examined in the current study. The formation of GSAs has been one way that schools have sought to improve the school climate for lesbian, gay, bisexual, and transgender (LGBT) youth. Limited information…

  19. Controllable synthesis of helical, straight, hollow and nitrogen-doped carbon nanofibers and their magnetic properties

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xun [State Key Laboratory of Coordination Chemistry, Nanjing National Laboratory of Microstructure, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093 (China); State Key Laboratory of Soil and Sustainable Agriculture, Institute of Soil Science, Chinese Academy of Sciences, Nanjing 210008 (China); Xu, Zheng, E-mail: zhengxu@nju.edu.cn [State Key Laboratory of Coordination Chemistry, Nanjing National Laboratory of Microstructure, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093 (China)

    2012-12-15

    Graphical abstract: The helical, straight and hollow carbon nanofibers can be selectively synthesized by adjusting either the reaction temperature or feed gas composition. Display Omitted Highlights: ► CNFs were synthesized via pyrolysis of acetylene on copper NPs. ► The helical, straight, hollow and N-doped CNFs can be selectively synthesized. ► The growth mechanism of different types of CNFs was proposed. -- Abstract: Carbon nanofibers (CNFs) with various morphologies were synthesized by catalytic pyrolysis of acetylene on copper nanoparticles which were generated from the in situ decomposition of copper acetylacetonate. The morphology of the pristine and acid-washed CNFs was investigated by field emission scanning electron microscope and high-resolution transmission electron microscope. Helical, straight and hollow CNFs can be selectively synthesized by adjusting either the reaction temperature or feed gas composition. The growth mechanism for these three types of CNFs was proposed.

  20. Head and pelvic movement asymmetry during lungeing in horses with symmetrical movement on the straight.

    Science.gov (United States)

    Rhodin, M; Roepstorff, L; French, A; Keegan, K G; Pfau, T; Egenvall, A

    2016-05-01

    Lungeing is commonly used as part of standard lameness examinations in horses. Knowledge of how lungeing influences motion symmetry in sound horses is needed. The aim of this study was to objectively evaluate the symmetry of vertical head and pelvic motion during lungeing in a large number of horses with symmetric motion during straight line evaluation. Cross-sectional prospective study. A pool of 201 riding horses, all functioning well and considered sound by their owners, were evaluated in trot on a straight line and during lungeing to the left and right. From this pool, horses with symmetric vertical head and pelvic movement during the straight line trot (n = 94) were retained for analysis. Vertical head and pelvic movements were measured with body mounted uniaxial accelerometers. Differences between vertical maximum and minimum head (HDmax, HDmin) and pelvic (PDmax, PDmin) heights between left and right forelimb and hindlimb stances were compared between straight line trot and lungeing in either direction. Vertical head and pelvic movements during lungeing were more asymmetric than during trot on a straight line. Common asymmetric patterns seen in the head were more upward movement during push-off of the outside forelimb and less downward movement during impact of the inside limb. Common asymmetric patterns seen in the pelvis were less upward movement during push-off of the outside hindlimb and less downward movement of the pelvis during impact of the inside hindlimb. Asymmetric patterns in one lunge direction were frequently not the same as in the opposite direction. Lungeing induces systematic asymmetries in vertical head and pelvic motion patterns in horses that may not be the same in both directions. These asymmetries may mask or mimic fore- or hindlimb lameness. © 2015 The Authors. Equine Veterinary Journal published by John Wiley & Sons Ltd on behalf of EVJ Ltd.

  1. An in-situ measuring method for planar straightness error

    Science.gov (United States)

    Chen, Xi; Fu, Luhua; Yang, Tongyu; Sun, Changku; Wang, Zhong; Zhao, Yan; Liu, Changjie

    2018-01-01

    According to some current problems in the course of measuring the plane shape error of workpiece, an in-situ measuring method based on laser triangulation is presented in this paper. The method avoids the inefficiency of traditional methods like knife straightedge as well as the time and cost requirements of coordinate measuring machine(CMM). A laser-based measuring head is designed and installed on the spindle of a numerical control(NC) machine. The measuring head moves in the path planning to measure measuring points. The spatial coordinates of the measuring points are obtained by the combination of the laser triangulation displacement sensor and the coordinate system of the NC machine, which could make the indicators of measurement come true. The method to evaluate planar straightness error adopts particle swarm optimization(PSO). To verify the feasibility and accuracy of the measuring method, simulation experiments were implemented with a CMM. Comparing the measurement results of measuring head with the corresponding measured values obtained by composite measuring machine, it is verified that the method can realize high-precise and automatic measurement of the planar straightness error of the workpiece.

  2. Assessment of comparative skills between hand-assisted and straight laparoscopic colorectal training on an augmented reality simulator.

    Science.gov (United States)

    Leblanc, F; Delaney, C P; Neary, P C; Rose, J; Augestad, K M; Senagore, A J; Ellis, C N; Champagne, B J

    2010-09-01

    The aim of this study was to compare skills sets during a hand-assisted and straight laparoscopic colectomy on an augmented reality simulator. Twenty-nine surgeons, assigned randomly in 2 groups, performed laparoscopic sigmoid colectomies on a simulator: group A (n = 15) performed hand-assisted then straight procedures; group B (n = 14) performed straight then hand-assisted procedures. Groups were compared according to prior laparoscopic colorectal experience, performance (time, instrument path length, and instrument velocity changes), technical skills, and operative error. Prior laparoscopic colorectal experience was similar in both groups. Both groups had better performances with the hand-assisted approach, although technical skill scores were similar between approaches. The error rate was higher with the hand-assisted approach in group A, but similar between both approaches in group B. These data define the metrics of performance for hand-assisted and straight laparoscopic colectomy on an augmented reality simulator. The improved scores with the hand-assisted approach suggest that with this simulator a hand-assisted model may be technically easier to perform, although it is associated with increased intraoperative errors.

  3. Fresnel diffraction correction by phase-considered iteration procedure in soft X-ray projection microscopy

    International Nuclear Information System (INIS)

    Shiina, Tatsuo; Suzuki, Tsuyoshi; Honda, Toshio; Ito, Atsushi; Kinjo, Yasuhito; Yoshimura, Hideyuki; Yada, Keiji; Shinohara, Kunio

    2009-01-01

    In soft X-ray projection microscopy, it is easy to alter the magnification by changing the distance between the pinhole and the specimen, while the image is blurred because the soft X-rays are diffracted through the propagation from specimen to CCD detector. We corrected the blurred image by the iteration procedure of Fresnel to inverse Fresnel transformation taking phase distribution of the specimen into account. The experiments were conducted at the BL-11A of the Photon Factory, KEK, Japan for the specimens such as glass-capillaries, latex-particles, dried mammalian cells and human chromosomes. Many of those blurred images were corrected adequately by the iteration procedure, though some images such as those which have high-contrast or are overlapped by small cells still remain to be improved.

  4. GPU acceleration of 3D forward and backward projection using separable footprints for X-ray CT image reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Meng; Fessler, Jeffrey A. [Michigan Univ., Ann Arbor, MI (United States). Dept. of Electrical Engineering and Computer Science

    2011-07-01

    Iterative 3D image reconstruction methods can improve image quality over conventional filtered back projection (FBP) in X-ray computed tomography. However, high computational costs deter the routine use of iterative reconstruction clinically. The separable footprint method for forward and back-projection simplifies the integrals over a detector cell in a way that is quite accurate and also has a relatively efficient CPU implementation. In this project, we implemented the separable footprints method for both forward and backward projection on a graphics processing unit (GPU) with NVDIA's parallel computing architecture (CUDA). This paper describes our GPU kernels for the separable footprint method and simulation results. (orig.)

  5. Transition duct system with straight ceramic liner for delivering hot-temperature gases in a combustion turbine engine

    Science.gov (United States)

    Wiebe, David J.

    2017-05-16

    A transition duct system (10) for delivering hot-temperature gases from a plurality of combustors in a combustion turbine engine is provided. The system includes an exit piece (16) for each combustor. The exit piece may include a straight path segment (26) for receiving a gas flow from a respective combustor. A straight ceramic liner (40) may be inwardly disposed onto a metal outer shell (38) along the straight path segment of the exit piece. Structural arrangements are provided to securely attach the ceramic liner in the presence of substantial flow path pressurization. Cost-effective serviceability of the transition duct systems is realizable since the liner can be readily removed and replaced as needed.

  6. Strain Imaging of Nanoscale Semiconductor Heterostructures with X-Ray Bragg Projection Ptychography

    Science.gov (United States)

    Holt, Martin V.; Hruszkewycz, Stephan O.; Murray, Conal E.; Holt, Judson R.; Paskiewicz, Deborah M.; Fuoss, Paul H.

    2014-04-01

    We report the imaging of nanoscale distributions of lattice strain and rotation in complementary components of lithographically engineered epitaxial thin film semiconductor heterostructures using synchrotron x-ray Bragg projection ptychography (BPP). We introduce a new analysis method that enables lattice rotation and out-of-plane strain to be determined independently from a single BPP phase reconstruction, and we apply it to two laterally adjacent, multiaxially stressed materials in a prototype channel device. These results quantitatively agree with mechanical modeling and demonstrate the ability of BPP to map out-of-plane lattice dilatation, a parameter critical to the performance of electronic materials.

  7. Computing segmentations directly from x-ray projection data via parametric deformable curves

    DEFF Research Database (Denmark)

    Dahl, Vedrana Andersen; Dahl, Anders Bjorholm; Hansen, Per Christian

    2018-01-01

    We describe an efficient algorithm that computes a segmented reconstruction directly from x-ray projection data. Our algorithm uses a parametric curve to define the segmentation. Unlike similar approaches which are based on level-sets, our method avoids a pixel or voxel grid; hence the number...... of unknowns is reduced to the set of points that define the curve, and attenuation coefficients of the segments. Our current implementation uses a simple closed curve and is capable of separating one object from the background. However, our basic algorithm can be applied to an arbitrary topology and multiple...

  8. An advanced straight tube heat exchanger in which a fluid flows at variable and elevated temperatures

    International Nuclear Information System (INIS)

    Mauget, C.; Benoit, G.; Stalport, G.

    1993-01-01

    Straight tube heat exchangers are used as steam generators in nuclear reactors such as in fast neutron nuclear power plants; elevated and highly variable temperatures induce very high thermal expansion constraints in these long straight tubes. In order to avoid the expansion problems, an expansion bellow is disposed between the heat exchanger and the collector tubular plate in such a way that the bundle differential expansions may be absorbed

  9. Faller Classification in Older Adults Using Wearable Sensors Based on Turn and Straight-Walking Accelerometer-Based Features.

    Science.gov (United States)

    Drover, Dylan; Howcroft, Jennifer; Kofman, Jonathan; Lemaire, Edward D

    2017-06-07

    Faller classification in elderly populations can facilitate preventative care before a fall occurs. A novel wearable-sensor based faller classification method for the elderly was developed using accelerometer-based features from straight walking and turns. Seventy-six older individuals (74.15 ± 7.0 years), categorized as prospective fallers and non-fallers, completed a six-minute walk test with accelerometers attached to their lower legs and pelvis. After segmenting straight and turn sections, cross validation tests were conducted on straight and turn walking features to assess classification performance. The best "classifier model-feature selector" combination used turn data, random forest classifier, and select-5-best feature selector (73.4% accuracy, 60.5% sensitivity, 82.0% specificity, and 0.44 Matthew's Correlation Coefficient (MCC)). Using only the most frequently occurring features, a feature subset (minimum of anterior-posterior ratio of even/odd harmonics for right shank, standard deviation (SD) of anterior left shank acceleration SD, SD of mean anterior left shank acceleration, maximum of medial-lateral first quartile of Fourier transform (FQFFT) for lower back, maximum of anterior-posterior FQFFT for lower back) achieved better classification results, with 77.3% accuracy, 66.1% sensitivity, 84.7% specificity, and 0.52 MCC score. All classification performance metrics improved when turn data was used for faller classification, compared to straight walking data. Combining turn and straight walking features decreased performance metrics compared to turn features for similar classifier model-feature selector combinations.

  10. Bed shear stress distribution in straight channels with arbitrary cross section

    DEFF Research Database (Denmark)

    Christensen, Henrik Bo; Fredsøe, Jørgen

    1998-01-01

    The bed shear stress distribution in straight open channels is affected by mechanisms as bed curvature of the cross section profile, shear diffusion, and secondary currents. This paper compares some analytical and numerical methods to estimate the bed shear stress distribution. The methods...

  11. Reduction of radiation risks in patients undergoing some X-ray examinations by using optimal projections: A Monte Carlo program-based mathematical calculation

    Directory of Open Access Journals (Sweden)

    A Chaparian

    2014-01-01

    Full Text Available The objectives of this paper were calculation and comparison of the effective doses, the risks of exposure-induced cancer, and dose reduction in the gonads for male and female patients in different projections of some X-ray examinations. Radiographies of lumbar spine [in the eight projections of anteroposterior (AP, posteroanterior (PA, right lateral (RLAT, left lateral (LLAT, right anterior-posterior oblique (RAO, left anterior-posterior oblique (LAO, right posterior-anterior oblique (RPO, and left posterior-anterior oblique (LPO], abdomen (in the two projections of AP and PA, and pelvis (in the two projections of AP and PA were investigated. A solid-state dosimeter was used for the measuring of the entrance skin exposure. A Monte Carlo program was used for calculation of effective doses, the risks of radiation-induced cancer, and doses to the gonads related to the different projections. Results of this study showed that PA projection of abdomen, lumbar spine, and pelvis radiographies caused 50%-57% lower effective doses than AP projection and 50%-60% reduction in radiation risks. Also use of LAO projection of lumbar spine X-ray examination caused 53% lower effective dose than RPO projection and 56% and 63% reduction in radiation risk for male and female, respectively, and RAO projection caused 28% lower effective dose than LPO projection and 52% and 39% reduction in radiation risk for males and females, respectively. About dose reduction in the gonads, using of the PA position rather than AP in the radiographies of the abdomen, lumbar spine, and pelvis can result in reduction of the ovaries doses in women, 38%, 31%, and 25%, respectively and reduction of the testicles doses in males, 76%, 86%, and 94%, respectively. Also for oblique projections of lumbar spine X-ray examination, with employment of LAO rather than RPO and also RAO rather than LPO, demonstrated 22% and 13% reductions to the ovaries doses and 66% and 54% reductions in the

  12. The short straight sections for the LHC

    International Nuclear Information System (INIS)

    Bergot, J.B.; Coussy, E.; Dambre, P.; Ollivier, Y.; Reynet, D.; Vincent, D.; Rohmig, P.

    1999-01-01

    In 1995 a close collaboration between CERN, CEA and CNRS has been established for the design, proto-typing and follow-up of industrial series production of a sub-assembly of the Large Hadron Collider (LHC). In this frame, the design office of IPN's Accelerator R and D group has in charge one of these contracts concerning the 386 Short Straight Sections (SSS) and particularly: - the cryostat design; - the study of procedures and tool assembly; - the construction of two prototypes during the year 1999; - the industrialization and the production follow-up for the series SSS. This collaboration will last until the year 2004. (authors)

  13. Secondary Flow Phenomena in Rotating Radial Straight Pipes

    OpenAIRE

    Cheng, K. C.; Wang, Liqiu

    1995-01-01

    Flow visualization results for secondary flow phenomena near the exit of a rotating radial-axis straight pipe (length ࡁ = 82 cm, inside diameter d = 3.81 cm, ࡁ/d 21.52) are presented to study the stabilizing (relaminarization) and destabilizing (early transition from laminar to turbulent flow) effects of Coriolis forces for Reynolds numbers Re = 500 ∼ 4,500 and rotating speeds n = 0 ∼ 200 rpm. The flow visualization was realised by smoke injection method. The main features of the trans...

  14. Scalar localization by cone-beam computed tomography of cochlear implant carriers: a comparative study between straight and periomodiolar precurved electrode arrays.

    Science.gov (United States)

    Boyer, Eric; Karkas, Alexandre; Attye, Arnaud; Lefournier, Virginie; Escude, Bernard; Schmerber, Sebastien

    2015-03-01

    To compare the incidence of dislocation of precurved versus straight flexible cochlear implant electrode arrays using cone-beam computed tomography (CBCT) image analyses. Consecutive nonrandomized case-comparison study. Tertiary referral center. Analyses of patients' CBCT images after cochlear implant surgery. Precurved and straight flexible electrode arrays from two different manufacturers were implanted. A round window insertion was performed in most cases. Two cases necessitated a cochleostomy. The patients' CBCT images were reconstructed in the coronal oblique, sagittal oblique, and axial oblique section. The insertion depth angle and the incidence of dislocation from the scala tympani to the scala vestibuli were determined. The CBCT images and the incidence of dislocation were analyzed in 54 patients (61 electrode arrays). Thirty-one patients were implanted with a precurved perimodiolar electrode array and 30 patients with a straight flexible electrode array. A total of nine (15%) scalar dislocations were observed in both groups. Eight (26%) scalar dislocations were observed in the precurved array group and one (3%) in the straight array group. Dislocation occurred at an insertion depth angle between 170 and 190 degrees in the precurved array group and at approximately 370 degrees in the straight array group. With precurved arrays, dislocation usually occurs in the ascending part of the basal turn of the cochlea. With straight flexible electrode arrays, the incidence of dislocation was lower, and it seems that straight flexible arrays have a higher chance of a confined position within the scala tympani than perimodiolar precurved arrays.

  15. Equilibrium charge distribution on a finite straight one-dimensional wire

    Science.gov (United States)

    Batle, Josep; Ciftja, Orion; Abdalla, Soliman; Elhoseny, Mohamed; Alkhambashi, Majid; Farouk, Ahmed

    2017-09-01

    The electrostatic properties of uniformly charged regular bodies are prominently discussed on college-level electromagnetism courses. However, one of the most basic problems of electrostatics that deals with how a continuous charge distribution reaches equilibrium is rarely mentioned at this level. In this work we revisit the problem of equilibrium charge distribution on a straight one-dimensional (1D) wire with finite length. The majority of existing treatments in the literature deal with the 1D wire as a limiting case of a higher-dimensional structure that can be treated analytically for a Coulomb interaction potential between point charges. Surprisingly, different models (for instance, an ellipsoid or a cylinder model) may lead to different results, thus there is even some ambiguity on whether the problem is well-posed. In this work we adopt a different approach where we do not start with any higher-dimensional body that reduces to a 1D wire in the appropriate limit. Instead, our starting point is the obvious one, a finite straight 1D wire that contains charge. However, the new tweak in the model is the assumption that point charges interact with each other via a non-Coulomb power-law interaction potential. This potential is well-behaved, allows exact analytical results and approaches the standard Coulomb interaction potential as a limit. The results originating from this approach suggest that the equilibrium charge distribution for a finite straight 1D wire is a uniform charge density when the power-law interaction potential approaches the Coulomb interaction potential as a suitable limit. We contrast such a finding to results obtained using a different regularised logarithmic interaction potential which allows exact treatment in 1D. The present self-contained material may be of interest to instructors teaching electromagnetism as well as students who will discover that simple-looking problems may sometimes pose important scientific challenges.

  16. Equilibrium charge distribution on a finite straight one-dimensional wire

    International Nuclear Information System (INIS)

    Batle, Josep; Ciftja, Orion; Abdalla, Soliman; Elhoseny, Mohamed; Farouk, Ahmed; Alkhambashi, Majid

    2017-01-01

    The electrostatic properties of uniformly charged regular bodies are prominently discussed on college-level electromagnetism courses. However, one of the most basic problems of electrostatics that deals with how a continuous charge distribution reaches equilibrium is rarely mentioned at this level. In this work we revisit the problem of equilibrium charge distribution on a straight one-dimensional (1D) wire with finite length. The majority of existing treatments in the literature deal with the 1D wire as a limiting case of a higher-dimensional structure that can be treated analytically for a Coulomb interaction potential between point charges. Surprisingly, different models (for instance, an ellipsoid or a cylinder model) may lead to different results, thus there is even some ambiguity on whether the problem is well-posed. In this work we adopt a different approach where we do not start with any higher-dimensional body that reduces to a 1D wire in the appropriate limit. Instead, our starting point is the obvious one, a finite straight 1D wire that contains charge. However, the new tweak in the model is the assumption that point charges interact with each other via a non-Coulomb power-law interaction potential. This potential is well-behaved, allows exact analytical results and approaches the standard Coulomb interaction potential as a limit. The results originating from this approach suggest that the equilibrium charge distribution for a finite straight 1D wire is a uniform charge density when the power-law interaction potential approaches the Coulomb interaction potential as a suitable limit. We contrast such a finding to results obtained using a different regularised logarithmic interaction potential which allows exact treatment in 1D. The present self-contained material may be of interest to instructors teaching electromagnetism as well as students who will discover that simple-looking problems may sometimes pose important scientific challenges. (paper)

  17. The hybrid reactor project based on the straight field line mirror concept

    Science.gov (United States)

    Ågren, O.; Noack, K.; Moiseenko, V. E.; Hagnestâl, A.; Källne, J.; Anglart, H.

    2012-06-01

    The straight field line mirror (SFLM) concept is aiming towards a steady-state compact fusion neutron source. Besides the possibility for steady state operation for a year or more, the geometry is chosen to avoid high loads on materials and plasma facing components. A comparatively small fusion hybrid device with "semi-poor" plasma confinement (with a low fusion Q factor) may be developed for industrial transmutation and energy production from spent nuclear fuel. This opportunity arises from a large fission to fusion energy multiplication ratio, Qr = Pfis/Pfus>>1. The upper bound on Qr is primarily determined by geometry and reactor safety. For the SFLM, the upper bound is Qr≈150, corresponding to a neutron multiplicity of keff=0.97. Power production in a mirror hybrid is predicted for a substantially lower electron temperature than the requirement Te≈10 keV for a fusion reactor. Power production in the SFLM seems possible with Q≈0.15, which is 10 times lower than typically anticipated for hybrids (and 100 times smaller than required for a fusion reactor). This relaxes plasma confinement demands, and broadens the range for use of plasmas with supra-thermal ions in hybrid reactors. The SFLM concept is based on a mirror machine stabilized by qudrupolar magnetic fields and large expander tanks beyond the confinement region. The purpose of the expander tanks is to distribute axial plasma loss flow over a sufficiently large area so that the receiving plates can withstand the heat. Plasma stability is not relying on a plasma flow into the expander regions. With a suppressed plasma flow into the expander tanks, a possibility arise for higher electron temperature. A brief presentation will be given on basic theory for the SFLM with plasma stability and electron temperature issues, RF heating computations with sloshing ion formation, neutron transport computations with reactor safety margins and material load estimates, magnetic coil designs as well as a discussion on

  18. Shielded transient self-interaction of a bunch entering a circle from a straight path

    International Nuclear Information System (INIS)

    Li, R.; Bohn, C.L.; Bisognano, J.J.

    1997-01-01

    When a short (mm-length) bunch with high (nC-regime) charge is transported through a magnetic bending system, self-interaction via coherent synchrotron radiation (CSR) and space charge may alter the bunch dynamics significantly. The authors consider a Gaussian rigid-line-charge bunch following a straight-path trajectory into a circle, with the trajectory centered between two infinite, parallel, perfectly conducting plates. Transients associated with CSR and space charge generated from source particles both on the straight path and the circle are calculated, and their net effect on the radiated power is contrasted with that of shielded steady-state CSR

  19. Novel Straight and Circular Road Driving Control of Electric Power Assisted Wheelchair Based on Fuzzy Algorithm

    Science.gov (United States)

    Seki, Hirokazu; Tadakuma, Susumu

    This paper describes a novel straight and circular road driving control scheme for electric power assisted wheelchairs. “Electric power assisted wheelchair” which assists the driving force by electric motors is expected to be widely used as a mobility support system for elderly people and disabled people, however, the performance of the straight and circular road driving must be further improved because the two wheels drive independently. This paper proposes a novel driving control scheme based on fuzzy algorithm to realize the stable and reliable driving on straight and circular roads. The suitable assisted torque of the right and left wheels is determined by fuzzy algorithm based on the posture angular velocity of the wheelchair and the human input torque proportion of the right and left wheels. Some experiments on the practical roads show the effectiveness of the proposed control system.

  20. X-ray phase radiography and tomography with grating interferometry and the reverse projection technique

    International Nuclear Information System (INIS)

    Wang, Zhili; Gao, Kun; Ge, Xin; Wu, Zhao; Chen, Heng; Wang, Shenghao; Wu, Ziyu; Zhu, Peiping; Yuan, Qingxi; Huang, Wanxia; Zhang, Kai

    2013-01-01

    X-ray grating interferometry provides substantially increased contrast over conventional absorption-based imaging methods, and therefore new and complementary information. Compared with other phase-contrast imaging techniques, x-ray grating interferometry can overcome some of the problems that have impaired the applications of x-ray phase-contrast radiography and phase tomography. Recently, special attention has been paid to the development of quantitative phase retrieval methods, which is mandatory to perform x-ray phase tomography, to achieve material identification, to differentiate distinct tissues, etc. Typically, the phase-stepping approach has been utilized for phase retrieval in grating interferometry. This method requires a grating scanning and acquisition of multiple radiographic projections, and therefore is disadvantageous in terms of imaging speed and radiation damage. Here we present an innovative, highly sensitive approach, dubbed ‘reverse projection’ (RP), for quantitative phase retrieval. Compared with the phase-stepping approach, the present RP method abandons grating scanning completely, and thus is advantageous due to its much higher efficiency and the reduced radiation dose, without the degradation of reconstruction quality. This review presents a detailed explanation of the principle of the RP method. Both radiography and phase tomography experiments are performed to validate the RP method. We believe that this new technique will find widespread applications in biomedical imaging and in vivo studies. (paper)

  1. Review of the analysis methods of surface crack for straight pipe and elbow

    International Nuclear Information System (INIS)

    Kim, H. S.; Jang, Y. S.; Jin, T. E.

    1999-01-01

    The objective of this paper is to find out optimum EPFM analysis methods of straight pipe and elbow by comparison of load-carrying capacities. To do this, analytical and finite element analyses were performed and then these results compared with the ones in the literatures and experimental data to verify the validity of the analysis results. Comparison results showed that NSC method for straight pipe and SC.ELB2 method for elbow were appropriate ones among analytical methods except FEM to predict load-carrying capacities. However, the trend of prediction results scattered according to the analysis conditions such as geometry and material as well as analytical methods, it is necessary for cautious application of the analytical methods

  2. The free energy profile of tubulin straight-bent conformational changes, with implications for microtubule assembly and drug discovery.

    Directory of Open Access Journals (Sweden)

    Lili X Peng

    2014-02-01

    Full Text Available αβ-tubulin dimers need to convert between a 'bent' conformation observed for free dimers in solution and a 'straight' conformation required for incorporation into the microtubule lattice. Here, we investigate the free energy landscape of αβ-tubulin using molecular dynamics simulations, emphasizing implications for models of assembly, and modulation of the conformational landscape by colchicine, a tubulin-binding drug that inhibits microtubule polymerization. Specifically, we performed molecular dynamics, potential-of-mean force simulations to obtain the free energy profile for unpolymerized GDP-bound tubulin as a function of the ∼12° intradimer rotation differentiating the straight and bent conformers. Our results predict that the unassembled GDP-tubulin heterodimer exists in a continuum of conformations ranging between straight and bent, but, in agreement with existing structural data, suggests that an intermediate bent state has a lower free energy (by ∼1 kcal/mol and thus dominates in solution. In agreement with predictions of the lattice model of microtubule assembly, lateral binding of two αβ-tubulins strongly shifts the conformational equilibrium towards the straight state, which is then ∼1 kcal/mol lower in free energy than the bent state. Finally, calculations of colchicine binding to a single αβ-tubulin dimer strongly shifts the equilibrium toward the bent states, and disfavors the straight state to the extent that it is no longer thermodynamically populated.

  3. Straight and chopped DC performance data for a reliance EV-250AT motor with a General Electric EV-1 controller

    Science.gov (United States)

    Edie, P. C.

    1981-01-01

    Straight and chopped DC motor performances for a Reliance EV-250AT motor with an EV-1 controller were examined. Effects of motor temperature and operating voltage are shown. It is found that the maximum motor efficiency is approximately 85% at low operating temperatures in the straight DC mode. Chopper efficiency is 95% under all operating conditions. For equal speeds, the motor operated in the chopped mode develops slightly more torque and draws more current than it does in the straight DC mode.

  4. CARNAÚBA: The Coherent X-Ray Nanoprobe Beamline for the Brazilian Synchrotron SIRIUS/LNLS

    Science.gov (United States)

    Tolentino, Hélio C. N.; Soares, Márcio M.; Perez, Carlos A.; Vicentin, Flávio C.; Abdala, Dalton B.; Galante, Douglas; Teixeira, Verônica de C.; de Araújo, Douglas H. C.; Westfahl, Harry, Jr.

    2017-06-01

    The CARNAÚBA beamline is the tender-to-hard X-ray (2 - 15 keV) scanning nanoprobe planned for the 4th generation storage ring SIRIUS at the LNLS. CARNAÚBA uses an undulator source with vertical linear polarization in a low-beta straight section and grazing incidence-focusing mirrors to create a nanoprobe at 143 m from the source. The beamline optic is based on KB mirrors and provides high brilliance at an achromatic focal spot down to the diffraction limit diameter of ˜30 nm with a working distance of ˜6 cm. These characteristics are crucial for studying nanometric samples in experiments involving complex stages and environments. The CARNAÚBA beamline aims to perform raster scans using x-ray fluorescence, x-ray absorption spectroscopy, x-ray diffraction and coherent x-ray imaging techniques. Computed tomography will extend these methods to three dimensions.

  5. A model based approach to reference-free straightness measurement at the Nanometer Comparator

    Science.gov (United States)

    Weichert, C.; Stavridis, M.; Walzel, M.; Elster, C.; Wiegmann, A.; Schulz, M.; Köning, R.; Flügge, J.; Tutsch, R.

    2009-06-01

    The Nanometer Comparator is the PTB reference length measuring machine for high precision calibrations of line scales and encoder systems. Up to now the Nanometer Comparator allows to measure the position of line structures in one dimension only. For high precision characterisations of masks, scales and incremental encoders, the measurement of the straightness of graduations is a requirement from emerging lithography techniques. Therefore the Nanometer Comparator will be equipped with an additional short range measurement system in the Y-direction, realized as a single path plane mirror interferometer and supposed to achieve sub-nm uncertainties. To compensate the topography of the Y-mirror, the Traceable Multi Sensor (TMS) method will be implemented to achieve a reference-free straightness measurement. Virtual experiments are used to estimate the lower accuracy limit and to determine the sensitive parameters. The virtual experiments contain the influence of the positioning devices, interferometer errors as well as non-perfect adjustment and fabrication of the machine geometry. The whole dynamic measurement process of the Nanometer Comparator including its influence on the TMS analysis, e.g. non-equally spaced measurement points, is simulated. We will present the results of these virtual experiments as well as the most relevant error sources for straightness measurement, incorporating the low uncertainties of the existing and planned measurement systems.

  6. Global Calibration of Multi-Cameras Based on Refractive Projection and Ray Tracing

    Directory of Open Access Journals (Sweden)

    Mingchi Feng

    2017-10-01

    Full Text Available Multi-camera systems are widely applied in the three dimensional (3D computer vision, especially when multiple cameras are distributed on both sides of the measured object. The calibration methods of multi-camera systems are critical to the accuracy of vision measurement and the key is to find an appropriate calibration target. In this paper, a high-precision camera calibration method for multi-camera systems based on transparent glass checkerboards and ray tracing is described, and is used to calibrate multiple cameras distributed on both sides of the glass checkerboard. Firstly, the intrinsic parameters of each camera are obtained by Zhang’s calibration method. Then, multiple cameras capture several images from the front and back of the glass checkerboard with different orientations, and all images contain distinct grid corners. As the cameras on one side are not affected by the refraction of glass checkerboard, extrinsic parameters can be directly calculated. However, the cameras on the other side are influenced by the refraction of glass checkerboard, and the direct use of projection model will produce a calibration error. A multi-camera calibration method using refractive projection model and ray tracing is developed to eliminate this error. Furthermore, both synthetic and real data are employed to validate the proposed approach. The experimental results of refractive calibration show that the error of the 3D reconstruction is smaller than 0.2 mm, the relative errors of both rotation and translation are less than 0.014%, and the mean and standard deviation of reprojection error of the four-camera system are 0.00007 and 0.4543 pixels, respectively. The proposed method is flexible, highly accurate, and simple to carry out.

  7. The PEP-II Project: Low-Energy Ring Design and Project Status

    International Nuclear Information System (INIS)

    Zisman, Michael S.

    2006-01-01

    We describe the present status of the PEP-II project. The project comprises four major systems: Injector, High-Energy Ring (HER), Low-Energy Ring (LER), and Interaction Region (IR). We focus in detail on the design of the LER, as its parameters and requirements are most closely related to those required for the Beijing Tau-Charm Factory rings. The PEP-II LER is a high-current, 3.1-GeV positron ring mounted above the 9-GeV HER. The LER uses a wiggler located in one of its six straight sections to provide emittance control and additional damping. We describe the rather complicated IR, which must transport the LER beam into the plane of the HER, focus it to a common beam size, and separate the beams after the head-on collisions. Both permanent magnet and conventional electromagnets are used in this area. The LER lattice has now adopted a simplified non-interleaved sextupole correction scheme that has reduced the required number of sextupoles substantially. We describe the LER vacuum system, one of the most challenging subsystems in PEP-II. It employs several technologies. In the arcs, aluminum extrusions and titanium sublimation pumps are employed; the straight sections use stainless steel chambers with lumped ion pumps. In the wiggler area, an extended copper photon dump with nonevaporable getter (NEG) pumps is employed to handle the very large synchrotron radiation power. The design of the room-temperature RF system, the bunch-by-bunch longitudinal and transverse feedback systems, and some of the special diagnostics will be described briefly. The PEP-II project remains on schedule to begin commissioning of the HER in April 1997, followed by the LER a year later

  8. Straight spinning cosmic strings in Brans-Dicke gravity

    Science.gov (United States)

    Dos Santos, S. Mittmann; da Silva, J. M. Hoff; Cindra, J. L.

    2018-03-01

    An exact solution of straight spinning cosmic strings in Brans-Dicke theory of gravitation is presented. The possibility of the existence of closed time-like curves around these cosmic strings is analyzed. Furthermore, the stability about the formation of the topological defect discussed here is checked. It is shown that the existence of a suitable choice for the integration constants in which closed time-like curves are not allowed. We also study the (im)possibility of using the obtained spacetime in the rotational curves problem.

  9. A general approach to flaw simulation in castings by superimposing projections of 3D models onto real X-ray images

    International Nuclear Information System (INIS)

    Hahn, D.; Mery, D.

    2003-01-01

    In order to evaluate the sensitivity of defect inspection systems, it is convenient to examine simulated data. This gives the possibility to tune the parameters of the inspection method and to test the performance of the system in critical cases. In this paper, a practical method for the simulation of defects in radioscopic images of aluminium castings is presented. The approach simulates only the flaws and not the whole radioscopic image of the object under test. A 3D mesh is used to model a flaw with complex geometry, which is projected and superimposed onto real radioscopic images of a homogeneous object according to the exponential attenuation law for X- rays. The new grey value of a pixel, where the 3D flaw is projected, depends only on four parameters: (a) the grey value of the original X-ray image without flaw; (b) the linear absorption coefficient of the examined material; (c) the maximal thickness observable in the radioscopic image; and (d) the length of the intersection of the 3D flaw with the modelled X-ray beam, that is projected into the pixel. A simulation of a complex flaw modelled as a 3D mesh can be performed in any position of the castings by using the algorithm described in this paper. This allows the evaluation of the performance of defect inspection systems in cases where the detection is known to be difficult. In this paper, we show experimental results on real X-ray images of aluminium wheels, in which 3D flaws like blowholes, cracks and inclusions are simulated

  10. Transitions in pedestrian fundamental diagrams of straight corridors and T-junctions

    International Nuclear Information System (INIS)

    Zhang, J; Klingsch, W; Schadschneider, A; Seyfried, A

    2011-01-01

    Many observations of pedestrian dynamics, including various self-organization phenomena, have been reproduced successfully by different models. But the empirical databases for quantitative calibration are still insufficient, e.g. the fundamental diagram as one of the most important relationships displays non-negligible differences among various studies. To improve this situation, experiments in straight corridors and T-junctions are performed. Four different measurement methods are defined to study their effects on the fundamental diagram. It is shown that they have minor influences for ρ −2 but only the Voronoi method is able to resolve the fine structure of the fundamental diagram. This enhanced measurement method permits us to observe the occurrence of a boundary-induced phase transition. For corridors of different widths we found that the specific flow concept works well for ρ −2 . Moreover, we illustrate the discrepancies between the fundamental diagrams of a T-junction and a straight corridor

  11. Radiation-induced desulfurization of Arabian crude oil and straight-run diesel

    International Nuclear Information System (INIS)

    Basfar, A.A.; Mohamed, K.A.

    2011-01-01

    Radiation-induced desulfurization of four types of Arabian crude oils (heavy, medium, light and extra light) and straight-run diesel (SRD) was investigated over the range of 10-200 kGy. Results show that gamma radiation processing at absorbed doses up to 200 kGy without further treatment is not sufficient for desulfurization. However, the combination of gamma-irradiation with other physical/chemical processes (i.e. L/L extraction, adsorption and oxidation) may be capable of removing considerable levels of sulfur compounds in the investigated products. Currently, this approach of combined radiation/physical/chemical processes is under investigation. The findings of these attempts will be reported in the future. - Highlights: → Irradiation effect on desulfurization in Arabian crude oils and straight-run diesel was investigated. → No noticeable changes in sulfur content after irradiation up to 200 kGy were observed. → Stricter regulations on sulfur levels in fuels motivate search for improved desulfurization processes. → Limited investigations on radiation-induced desulfurization of oil products are conducted.

  12. Straight and Curved Path Walking Among Older Adults in Primary Care: Associations With Fall-Related Outcomes.

    Science.gov (United States)

    Welch, Sarah A; Ward, Rachel E; Kurlinski, Laura A; Kiely, Dan K; Goldstein, Richard; VanSwearingen, Jessie; Brach, Jennifer S; Bean, Jonathan F

    2016-08-01

    Most falls among community-dwelling older adults occur while walking. Simple walking tests that require little resources and can be interpreted quickly are advocated as useful screening tools for fall prone patients. To investigate 2 clinically feasible walking tests consisting of straight- and curved-path walking and examine their associations with history of previous falls and fall-related outcomes among community-living older adults. A cross-sectional analysis was performed on baseline data from a longitudinal cohort study. Participants were recruited through primary care practices. Participants included 428 primary care patients ≥65 years of age at risk for mobility decline. Participants had a median age of 76.5 years, 67.8% were women, and 82.5% were white. Straight-path walking performance was measured as the time needed to walk a 4-meter straight path at usual pace from standstill using a stopwatch (timed to 0.1 second). Curved-path walking performance was timed while participants walked from standstill in a figure-of-8 pattern around two cones placed 5 feet apart. Multivariable negative binomial regression analyses were performed to assess the relationship between straight-path walking or curved-path walking and self-reported history of number of falls. For fall-related injuries, and fall-related hospitalizations, logistic regression models were used. In the fully adjusted model, an increase of 1 second in straight path walking time was associated with 26% greater rate of falls (rate ratio 1.26, 95% confidence interval 1.10-1.45). An increase in curved-path walking time was associated with 8% greater rate of falls (rate ratio 1.08, 95% confidence interval = 1.03-1.14). Neither walk test was associated with history of fall-related injuries or hospitalizations. Poor performance on straight- and curved-path walking performance was associated with a history of greater fall rates in the previous year but not with a history of fall-related injuries or

  13. Improving education and supervision of Queensland X-ray Operators through video conference technology: A teleradiography pilot project.

    Science.gov (United States)

    Rawle, Marnie; Oliver, Tanya; Pighills, Alison; Lindsay, Daniel

    2017-12-01

    X-ray Operator (XO) supervision in Queensland is performed by radiographers in a site removed from the XO site. This has historically been performed by telephone when the XO requires immediate help, as well as post-examination through radiographer review and the provision of written feedback on images produced. This project aimed to improve image quality through the provision of real-time support of XOs by the introduction of video conference (VC) supervision. A 6-month pilot project compared image quality with and without VC supervision. VC equipment was installed in the X-ray room at two rural sites, as well as at the radiographer site, to enable visual and oral supervision. The VC unit enabled visualisation of the X-ray examination technique as it was being undertaken, as well as the images produced prior to transmission to the Picture Archiving and Communication System (PACS). Statistically significant improvement in image quality criteria measures were seen for patient positioning (P = 0.008), image quality (P < 0.001) and diagnostic value (P < 0.001) of images taken during this project. No statistically significant differences were seen during case level assessment in the inclusion of only appropriate imaging (P = 0.06), and the inclusion of unacceptable imaging (P = 0.06), however improvements were seen in both of these criteria. The survey revealed 24.6% of examinations performed would normally have involved the XO contacting the radiographer for assistance, although, assistance was actually provided in 88.3% of examinations. This project has demonstrated that significant improvement in image quality is achievable with VC supervision. A larger study with a control arm that did not receive direct supervision should be used to validate the findings of this study. © 2017 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand

  14. Restoration of lumbopelvic sagittal alignment and its maintenance following transforaminal lumbar interbody fusion (TLIF): comparison between straight type versus curvilinear type cage.

    Science.gov (United States)

    Kim, Jong-Tae; Shin, Myung-Hoon; Lee, Ho-Jin; Choi, Du-Yong

    2015-11-01

    To evaluate a radiological and clinical difference between the curvilinear type cages compared to the straight type cages for the restoration of lumbopelvic sagittal alignment and its maintenance after transforaminal lumbar interbody fusion (TLIF) procedure. 68 patients who underwent single-level TLIF using either the straight type or curvilinear type cage were retrospectively reviewed. Assessment of the lumbopelvic parameters and the height of disc space was performed before surgery as well as 2 days, 6 and 12 months after surgery. Clinical outcome was assessed using VAS and ODI. The curvilinear type cages were positioned more anteriorly than the straight type. Restoration of the segmental lordosis (SL) in the curvilinear group was significantly greater than the straight group and at 12 months of follow-up, the straight group showed greater decrease in the disc height than the curvilinear group. The straight group failed to show improvement of lumbar lordosis (LL), while the curvilinear group showed significant restoration of LL and could maintain it to the 6 months of follow-up. In both groups, pelvic tilt was significantly decreased and it lasted to 6 months in the straight group; whereas in the curvilinear group, it was maintained to the last follow-up of 12 months. There were no significant differences between the two groups in mean VAS and ODI score over the follow-up period. This study demonstrates that the curvilinear type cage is superior to the straight type cage in improving the SL and maintaining both the restored lumbopelvic parameters and elevated disc height. These results could be attributable to the anterior position of the curvilinear cage which permits easy restoration of segmental lordosis and less sinking of cages.

  15. Single-shot soft x-ray laser-induced ablative microstructuring of organic polymer with demagnifying projection

    Czech Academy of Sciences Publication Activity Database

    Mocek, Tomáš; Rus, Bedřich; Kozlová, Michaela; Polan, Jiří; Homer, Pavel; Juha, Libor; Hájková, Věra; Chalupský, Jaromír

    2008-01-01

    Roč. 33, č. 10 (2008), s. 1087-1089 ISSN 0146-9592 R&D Projects: GA AV ČR KAN300100702; GA ČR GA202/05/2316; GA MŠk LC510; GA MŠk(CZ) LC528; GA MŠk LA08024 Institutional research plan: CEZ:AV0Z10100523 Keywords : x-ray lasers * laser ablation * microstructuring Subject RIV: BH - Optics, Masers, Lasers Impact factor: 3.772, year: 2008

  16. Design of the compressor/stretcher ring of the Japanese Hadron Project

    International Nuclear Information System (INIS)

    Ohmori, C.; Noda, A.; Kimiya, Y.; Kihara, M.; Yamane, I.

    1991-01-01

    A possibility of adopting a racetrack-type design for the compressor/stretcher ring of the Japanese Hadron Project is described. This design has two long straight sections to enable to inject the H - beam and to produce a high β point for the slow extraction. (author)

  17. Design of the compressor/stretcher ring of the Japanese Hadron Project

    International Nuclear Information System (INIS)

    Ohmori, C.; Noda, A.; Kamiya, Y.; Kihara, M.; Yamane, I.

    1991-02-01

    A possibility of adopting a racetrack-type design for the compressor/stretcher ring of the Japanese Hadron Project is described. This design has two long straight sections to enable to inject the H - beam and to produce a high β point for the slow extraction. (author)

  18. Biomechanical differences in the stem straightening process among Pinus pinaster provenances. A new approach for early selection of stem straightness.

    Science.gov (United States)

    Sierra-de-Grado, Rosario; Pando, Valentín; Martínez-Zurimendi, Pablo; Peñalvo, Alejandro; Báscones, Esther; Moulia, Bruno

    2008-06-01

    Stem straightness is an important selection trait in Pinus pinaster Ait. breeding programs. Despite the stability of stem straightness rankings in provenance trials, the efficiency of breeding programs based on a quantitative index of stem straightness remains low. An alternative approach is to analyze biomechanical processes that underlie stem form. The rationale for this selection method is that genetic differences in the biomechanical processes that maintain stem straightness in young plants will continue to control stem form throughout the life of the tree. We analyzed the components contributing most to genetic differences among provenances in stem straightening processes by kinetic analysis and with a biomechanical model defining the interactions between the variables involved (Fournier's model). This framework was tested on three P. pinaster provenances differing in adult stem straightness and growth. One-year-old plants were tilted at 45 degrees, and individual stem positions and sizes were recorded weekly for 5 months. We measured the radial extension of reaction wood and the anatomical features of wood cells in serial stem cross sections. The integral effect of reaction wood on stem leaning was computed with Fournier's model. Responses driven by both primary and secondary growth were involved in the stem straightening process, but secondary-growth-driven responses accounted for most differences among provenances. Plants from the straight-stemmed provenance showed a greater capacity for stem straightening than plants from the sinuous provenances mainly because of (1) more efficient reaction wood (higher maturation strains) and (2) more pronounced secondary-growth-driven autotropic decurving. These two process-based traits are thus good candidates for early selection of stem straightness, but additional tests on a greater number of genotypes over a longer period are required.

  19. Cost-Benefit Analysis for Investment Decisions: Chapter 16 (Cost-Benefit Analysis of Transportation Projects)

    OpenAIRE

    Glenn Jenkins; Chun-Yan Kuo; Arnold C. Harberger

    2011-01-01

    This chapter will focus on the problems of evaluating transportation projects in the context of the less-developed countries. Emphasis will be placed on highway projects, because these account for the bulk of transport investments in the developing parts of the world. If a project passes a straight financial test, based on the present value of its cash inflows and outflows, projects would only come if this financial NPV were outweighed by the present value of the project’s various externali...

  20. Available friction of ladder shoes and slip potential for climbing on a straight ladder.

    Science.gov (United States)

    Chang, Wen-Ruey; Chang, Chien-Chi; Matz, Simon

    2005-07-15

    Straight ladder accidents are a major safety problem. As a leading cause of injuries involving straight ladders, slips at the ladder base occur when the required friction exceeds the available friction at the ladder shoe and floor interface. The objectives of this experiment were to measure the available friction at the base of a portable straight ladder in contact with a floor and to estimate the slip potential of the ladder. The results of friction measurements indicated that the measured friction coefficient on the oily surfaces differed among the six commercially available ladder shoes evaluated. A statistical model was used to compare the available friction results from the current study with the friction requirements under different climbing conditions from a previous study based on their stochastic distributions to estimate the slip potential at the base of the ladder. The results showed that different climbing conditions used in the previous study could be supported by available friction on dry surfaces. However, when the ladder was put onto oily surfaces, resulting in a significant reduction in the available friction due to contamination, slip potential was significantly increased.

  1. Effect of Hartmann layer resolution for MHD flow in a straight ...

    Indian Academy of Sciences (India)

    851–861. c Indian Academy of Sciences. Effect of Hartmann layer resolution for MHD flow in a straight, conducting duct at high Hartmann numbers. SHARANYA SUBRAMANIAN1,∗, P K SWAIN2,. A V DESHPANDE1 and P SATYAMURTHY2. 1Mechanical Engineering Department, Veermata Jijabai Technological Institute,.

  2. Straight A's: Public Education Policy and Progress. Volume 12, Number 2

    Science.gov (United States)

    Amos, Jason, Ed.

    2012-01-01

    "Straight A's: Public Education Policy and Progress" is a biweekly newsletter that focuses on education news and events both in Washington, DC and around the country. The following articles are included in this issue: (1) Waiving Away High School Graduation Rate Accountability?: State NCLB Waiver Proposals Threaten to Weaken…

  3. Straight-run vs. sex separate rearing for 2 broiler genetic lines Part 1: Live production parameters, carcass yield, and feeding behavior.

    Science.gov (United States)

    Da Costa, M J; Zaragoza-Santacruz, S; Frost, T J; Halley, J; Pesti, G M

    2017-08-01

    The objective of this experiment was to evaluate the effects of raising broilers under sex separate and straight-run conditions for 2 broiler strains. Day-old Ross 308 and Ross 708 chicks (n = 1,344) were separated by sex and placed in 48 pens according to the rearing type: sex separate (28 males or 28 females) or straight-run (14 males + 14 females). There were 3 dietary phases: starter (zero to 17 d), grower (17 to 32 d), and finisher (32 to 48 d). Birds' individual BW and feed intakes were measured at 12, 17, 25, 32, 42, and 48 d to evaluate performance. At 33, 43, and 49 d, 4 birds per pen were sampled for carcass yield evaluation. Additionally, from 06:00 to 06:30, 13:00 to 13:30, and 22:00 to 22:30, video records were taken to assess behavior at 45 days. Data were analyzed as CRD with a 2 × 3 factorial arrangement of treatments over time. Throughout the experiment Ross 308 were heavier than the 708, and after 17 d, male pens had the heavier birds, followed by straight-run and then females. Straight-run pens had higher BW CV in comparison with sex separate pens. Sex separate male BW was negatively impacted from 17 to 32 days. On the other hand, females raised sex separate were heavier than females raised straight-run with lower CV from 25 to 41 days. Post 25 d, FCR was the lowest in male pens whereas feed intake was the highest for these pens after 17 days. Overall, males had total carcass cut-up weights higher than straight-run and females at the 3 processing times. The Ross 708 had higher white meat yields, whereas 308 had higher yields for dark meat. Feeding behavior results were not consistent over time. However, from 13:00 to 13:30, birds in female pens spent more time eating, followed by straight-run and then males. In conclusion, raising females in a straight-run system negatively impacted performance and CV, whereas males benefited from straight-run rearing, with the differences being possibly related to feeder space competition. © 2017

  4. Status of the Short-Pulse X-ray Project (SPX) at the Advanced Photon Source (APS)

    International Nuclear Information System (INIS)

    Nassiri, R.; Arnold, N.D.; Berenc, G.; Borland, M.; Bromberek, D.J.; Chae, Y.-C.; Decker, G.; Emery, L.; Fuerst, J.D.; Grelick, A.E.; Horan, D.; Lenkszus, F.; Lill, R.M.; Sajaev, V.; Smith, T.L.; Waldschmidt, G.J.; Wu, G.; Yang, B.X.; Zholents, A.; Byrd, J.M.; Doolittle, L.R.; Huang, G.; Cheng, G.; Ciovati, G.; Henry, J.; Kneisel, P.; Mammosser, J.D.; Rimmer, R.A.; Turlington, L.; Wang, H.

    2011-01-01

    The Advanced Photon Source Upgrade project (APS-U) at Argonne includes implementation of Zholents deflecting cavity scheme for production of short x-ray pulses. This is a joint project between Argonne National Laboratory, Thomas Jefferson National Laboratory, and Lawrence Berkeley National Laboratory. This paper describes performance characteristics of the proposed source and technical issues related to its realization. Ensuring stable APS storage ring operation requires reducing quality factors of these modes by many orders of magnitude. These challenges reduce to those of the design of a single-cell SC cavity that can achieve the desired operating deflecting fields while providing needed damping of all these modes. The project team is currently prototyping and testing several promising designs for single-cell cavities with the goal of deciding on a winning design in the near future. Here we describe the approach undertaken and report the preliminary results. The concept of using transverse superconducting rf deflecting cavities to produce high-repetition-rate picoseconds x-rays with the APS has been previously described. Briefly, two cavities are required: the first cavity to impose a chirp on the electron beam and a second cavity to cancel the effects on the electron beam of the first cavity. The cavities must have a deflecting mode frequency that is a harmonic h of the APS storage ring rf frequency, 352 MHz A workable choice of h=8 corresponds to a deflecting cavity frequency of 2815 MHz. R and D activities include design and prototyping of superconducting deflecting cavities and components, cryomodule, low-level rf, particle/optical beam diagnostics, and timing/synchronization.

  5. The Laser of the ALICE Time Projection Chamber

    CERN Document Server

    Renault, G; Westergaard, J; GaardhOJe, J J

    2007-01-01

    The large TPC ($95 \\mathrm{m}^3$) of the ALICE detector at the CERN LHC was commissioned in summer 2006. The first tracks were observed both from the cosmic ray muons and from the laser rays injected into the TPC. In this article the basic principles of operating the $266 \\mathrm{nm}$ lasers are presented, showing the installation and adjustment of the optical system and describing the control system. To generate the laser tracks, a wide laser beam is split into several hundred narrow beams by fixed micro-mirrors at stable and known positions throughout the TPC. In the drift volume, these narrow beams generate straight tracks at many angles. Here we describe the generation of the first tracks and compare them with simulations.

  6. Measurement of cosmic-ray muons with the Distributed Electronic Cosmic-ray Observatory, a network of smartphones

    International Nuclear Information System (INIS)

    Vandenbroucke, J.; Bravo, S.; Karn, P.; Meehan, M.; Plewa, M.; Schultz, D.; Tosi, D.; BenZvi, S.; Jensen, K.; Peacock, J.; Ruggles, T.; Santander, M.; Simons, A.L.

    2016-01-01

    Solid-state camera image sensors can be used to detect ionizing radiation in addition to optical photons. We describe the Distributed Electronic Cosmic-ray Observatory (DECO), an app and associated public database that enables a network of consumer devices to detect cosmic rays and other ionizing radiation. In addition to terrestrial background radiation, cosmic-ray muon candidate events are detected as long, straight tracks passing through multiple pixels. The distribution of track lengths can be related to the thickness of the active (depleted) region of the camera image sensor through the known angular distribution of muons at sea level. We use a sample of candidate muon events detected by DECO to measure the thickness of the depletion region of the camera image sensor in a particular consumer smartphone model, the HTC Wildfire S. The track length distribution is fit better by a cosmic-ray muon angular distribution than an isotropic distribution, demonstrating that DECO can detect and identify cosmic-ray muons despite a background of other particle detections. Using the cosmic-ray distribution, we measure the depletion thickness to be 26.3 ± 1.4 μm. With additional data, the same method can be applied to additional models of image sensor. Once measured, the thickness can be used to convert track length to incident polar angle on a per-event basis. Combined with a determination of the incident azimuthal angle directly from the track orientation in the sensor plane, this enables direction reconstruction of individual cosmic-ray events using a single consumer device. The results simultaneously validate the use of cell phone camera image sensors as cosmic-ray muon detectors and provide a measurement of a parameter of camera image sensor performance which is not otherwise publicly available

  7. gamma. -ray. Present status and problems

    Energy Technology Data Exchange (ETDEWEB)

    Okudaira, K [Rikkyo Univ., Tokyo (Japan). Faculty of Science

    1975-01-01

    As ..gamma..-ray advances straightly through space, the study on cosmic ..gamma..-ray will give the information concerning the origin directly. However, the intensity is weak, and the avoidance of background is a serious problem. The wide-spread components were studied by OSO-3. The intensity of the galactic disc component around 100 MeV was reported as (3.4+-1.0)x10/sup -5/ photons (cm/sup 2/, radian, sec)/sup -1/ by OSO-3 and 0.2x10/sup -4/ photons (cm/sup 2/, radian sec)/sup -1/ by SAS-2, and corresponds to the calculated ..gamma.. yield from ..pi../sup 0/. The strong disc component, so-called galactic center region, has been observed, and is due to the mixture of ..gamma..-ray from ..pi../sup 0/ and inverse Compton ..gamma..-ray. A peak at 476+-24 KeV was found as well as the continuous component. Special care must be taken for the observation of isotropic component, since it is hardly distinguished from the background. It is considered that the isotropic component is due to the inverse Compton scattering of 3/sup 0/K radiation in super-galactic space and the contribution from outer galaxy. The nearest point source of ..gamma..-ray is the sun. Among the other point sources, the crab nebula is the most reliable one. The energy flux of pulse component showed the spectrum of E/sup -1/. ..gamma..-ray bursts were observed by man-made satellites Vela-5 and 6. Theoretical explanation is still incomplete regarding the bursts. (Kato, T.).

  8. X-ray image intensifier tube and radiographic camera incorporating same

    International Nuclear Information System (INIS)

    1981-01-01

    An X-ray sensitive image intensifier tube is described. It has an input window comprising at least one of iron, chromium and nickel for receiving an X-ray image. There is a flat scintillator screen adjacent for converting the X-ray image into a light pattern image. Adjacent to this is a flat photocathode layer for emitting photoelectrons in a pattern corresponding to the light pattern image. Parallel to this and spaced from it is a flat phosphor display screen. Electrostatic voltage is applied to the display screen and the photocathode layer to create an electric field between them to accelerate the photoelectrons towards the display screen. The paths of such parallel straight trajectories are governed solely by the electrostatic voltage applied, the image at the display screen being substantially equal in size to that of the X-ray image received at the input window. The tube envelope is preferably metallic to enable the basic components to be kept at a neutral potential and avoid spurious emissions. A radiographic camera with such an intensifier tube is also described. (U.K.)

  9. X-rays of inner worlds: the mid-twentieth-century American projective test movement.

    Science.gov (United States)

    Lemov, Rebecca

    2011-01-01

    This essay begins to tell the neglected history of the projective test movement in the U.S. behavioral sciences from approximately 1941 to 1968. This cross-disciplinary enterprise attempted to use projective techniques as "X-ray" machines to see into the psyches of subjects tested around the world. The aim was to gather subjective materials en masse, pursuing data on a scope, scale, and manner rarely hazarded before in any science. In particular, the targeted data included the traces of the inner life and elusive aspects of subjective experience including dreams, life stories, and myriad test results from a battery of tests. This essay explores how the movement and the experimental data bank that resulted were unlikely yet telling sites for the practice and pursuit of the Cold War human sciences. To look closely at the encounters that resulted is to show how the most out-of-the-way places and seemingly insignificant moments played a role in heady scientific ambitions and global geopolitical projects. At times, the projective test movement became a mirror of Cold War rationality itself, as tests were employed at the very limits of their possible extension. The essay argues for an off-kilter centrality in the movement itself, shedding light on the would-be unified social sciences after World War II and the "subjective turn" they took. © 2011 Wiley Periodicals, Inc.

  10. Free-boundary stability of straight stellarators

    International Nuclear Information System (INIS)

    Barnes, D.C.; Cary, J.R.

    1984-02-01

    The sharp-boundary model is used to investigate the stability of straight stellarators to free-boundary, long-wavelength modes. To correctly analyze the heliac configuration, previous theory is generalized to the case of arbitrary helical aspect ratio (ratio of plasma radius to periodicity lengths). A simple low-β criterion involving the vacuum field and the normalized axial current is derived and used to investigate a large variety of configurations. The predictions of this low-β theory are verified by numerical minimization of deltaW at arbitrary β. The heliac configuration is found to be remarkably stable, with a critical β of over 15% determined by the lack of equilibrium rather than the onset of instability. In addition, other previously studied systems are found to be stabilized by net axial plasma current

  11. High performance dosimetry calculations using adapted ray-tracing

    International Nuclear Information System (INIS)

    Perrotte, Lancelot; Saupin, Guillaume

    2010-01-01

    When preparing interventions on nuclear sites, it is interesting to study different scenarios, to identify the most appropriate one for the operator(s). Using virtual reality tools is a good way to simulate the potential scenarios. Thus, taking advantage of very efficient computation times can help the user studying different complex scenarios, by immediately evaluating the impact of any changes. In the field of radiation protection, people often use computation codes based on the straight line attenuation method with build-up factors. As for other approaches, geometrical computations (finding all the interactions between radiation rays and the scene objects) remain the bottleneck of the simulation. We present in this paper several optimizations used to speed up these geometrical computations, using innovative GPU ray-tracing algorithms. For instance, we manage to compute every intersection between 600 000 rays and a huge 3D industrial scene in a fraction of second. Moreover, our algorithm works the same way for both static and dynamic scenes, allowing easier study of complex intervention scenarios (where everything moves: the operator(s), the shielding objects, the radiation sources).

  12. Trends in Canadian Newspaper Coverage of Gay-Straight Alliances, 2000-2009

    Science.gov (United States)

    Herriot, Lindsay

    2011-01-01

    Gay-straight alliances (GSAs) in Canadian public schools have gained considerable attention from print media since reports first surfaced in the year 2000. This study tracked and analyzed Canadian newspaper reporting about GSA creation. It summarized the shift in public opinion toward lesbian, gay, bisexual, transgender, and queer (LGBTQ) youth…

  13. The hybrid reactor project based on the straight field line mirror concept

    International Nuclear Information System (INIS)

    Ågren, O.; Noack, K.; Moiseenko, V. E.; Hagnestål, A.; Källne, J.; Anglart, H.

    2012-01-01

    The straight field line mirror (SFLM) concept is aiming towards a steady-state compact fusion neutron source. Besides the possibility for steady state operation for a year or more, the geometry is chosen to avoid high loads on materials and plasma facing components. A comparatively small fusion hybrid device with “semi-poor” plasma confinement (with a low fusion Q factor) may be developed for industrial transmutation and energy production from spent nuclear fuel. This opportunity arises from a large fission to fusion energy multiplication ratio, Q r = P fis /P fus >>1. The upper bound on Q r is primarily determined by geometry and reactor safety. For the SFLM, the upper bound is Q r ≈150, corresponding to a neutron multiplicity of k eff =0.97. Power production in a mirror hybrid is predicted for a substantially lower electron temperature than the requirement T e ≈10 keV for a fusion reactor. Power production in the SFLM seems possible with Q≈0.15, which is 10 times lower than typically anticipated for hybrids (and 100 times smaller than required for a fusion reactor). This relaxes plasma confinement demands, and broadens the range for use of plasmas with supra-thermal ions in hybrid reactors. The SFLM concept is based on a mirror machine stabilized by qudrupolar magnetic fields and large expander tanks beyond the confinement region. The purpose of the expander tanks is to distribute axial plasma loss flow over a sufficiently large area so that the receiving plates can withstand the heat. Plasma stability is not relying on a plasma flow into the expander regions. With a suppressed plasma flow into the expander tanks, a possibility arise for higher electron temperature. A brief presentation will be given on basic theory for the SFLM with plasma stability and electron temperature issues, RF heating computations with sloshing ion formation, neutron transport computations with reactor safety margins and material load estimates, magnetic coil designs as well as

  14. Hand-assisted versus straight laparoscopic sigmoid colectomy on a training simulator: what is the difference? A stepwise comparison of hand-assisted versus straight laparoscopic sigmoid colectomy performance on an augmented reality simulator.

    LENUS (Irish Health Repository)

    Leblanc, Fabien

    2010-12-01

    We hypothesized that simulator-generated metrics and intraoperative errors may be able to differentiate the technical differences between hand-assisted laparoscopic (HAL) and straight laparoscopic (SL) approaches.

  15. Clinical application and validation of an iterative forward projection matching algorithm for permanent brachytherapy seed localization from conebeam-CT x-ray projections

    Energy Technology Data Exchange (ETDEWEB)

    Pokhrel, Damodar; Murphy, Martin J.; Todor, Dorin A.; Weiss, Elisabeth; Williamson, Jeffrey F. [Department of Radiation Oncology, School of Medicine, Virginia Commonwealth University, Richmond, Virginia 23298 (United States)

    2010-09-15

    Purpose: To experimentally validate a new algorithm for reconstructing the 3D positions of implanted brachytherapy seeds from postoperatively acquired 2D conebeam-CT (CBCT) projection images. Methods: The iterative forward projection matching (IFPM) algorithm finds the 3D seed geometry that minimizes the sum of the squared intensity differences between computed projections of an initial estimate of the seed configuration and radiographic projections of the implant. In-house machined phantoms, containing arrays of 12 and 72 seeds, respectively, are used to validate this method. Also, four {sup 103}Pd postimplant patients are scanned using an ACUITY digital simulator. Three to ten x-ray images are selected from the CBCT projection set and processed to create binary seed-only images. To quantify IFPM accuracy, the reconstructed seed positions are forward projected and overlaid on the measured seed images to find the nearest-neighbor distance between measured and computed seed positions for each image pair. Also, the estimated 3D seed coordinates are compared to known seed positions in the phantom and clinically obtained VariSeed planning coordinates for the patient data. Results: For the phantom study, seed localization error is (0.58{+-}0.33) mm. For all four patient cases, the mean registration error is better than 1 mm while compared against the measured seed projections. IFPM converges in 20-28 iterations, with a computation time of about 1.9-2.8 min/iteration on a 1 GHz processor. Conclusions: The IFPM algorithm avoids the need to match corresponding seeds in each projection as required by standard back-projection methods. The authors' results demonstrate {approx}1 mm accuracy in reconstructing the 3D positions of brachytherapy seeds from the measured 2D projections. This algorithm also successfully localizes overlapping clustered and highly migrated seeds in the implant.

  16. Clinical application and validation of an iterative forward projection matching algorithm for permanent brachytherapy seed localization from conebeam-CT x-ray projections.

    Science.gov (United States)

    Pokhrel, Damodar; Murphy, Martin J; Todor, Dorin A; Weiss, Elisabeth; Williamson, Jeffrey F

    2010-09-01

    To experimentally validate a new algorithm for reconstructing the 3D positions of implanted brachytherapy seeds from postoperatively acquired 2D conebeam-CT (CBCT) projection images. The iterative forward projection matching (IFPM) algorithm finds the 3D seed geometry that minimizes the sum of the squared intensity differences between computed projections of an initial estimate of the seed configuration and radiographic projections of the implant. In-house machined phantoms, containing arrays of 12 and 72 seeds, respectively, are used to validate this method. Also, four 103Pd postimplant patients are scanned using an ACUITY digital simulator. Three to ten x-ray images are selected from the CBCT projection set and processed to create binary seed-only images. To quantify IFPM accuracy, the reconstructed seed positions are forward projected and overlaid on the measured seed images to find the nearest-neighbor distance between measured and computed seed positions for each image pair. Also, the estimated 3D seed coordinates are compared to known seed positions in the phantom and clinically obtained VariSeed planning coordinates for the patient data. For the phantom study, seed localization error is (0.58 +/- 0.33) mm. For all four patient cases, the mean registration error is better than 1 mm while compared against the measured seed projections. IFPM converges in 20-28 iterations, with a computation time of about 1.9-2.8 min/ iteration on a 1 GHz processor. The IFPM algorithm avoids the need to match corresponding seeds in each projection as required by standard back-projection methods. The authors' results demonstrate approximately 1 mm accuracy in reconstructing the 3D positions of brachytherapy seeds from the measured 2D projections. This algorithm also successfully localizes overlapping clustered and highly migrated seeds in the implant.

  17. Silicon Wafer X-ray Mirror Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to undertake the initial development of a Kirkpatrick-Baez (K-B) type X-ray mirror using the relatively recent availability of high quality, inexpensive,...

  18. The EEE Project: cosmic rays, multigap resistive plate chambers and high school students

    International Nuclear Information System (INIS)

    Abbrescia, M; Aiola, S; Antolini, R; Coccia, E; Giovanni, A Di; D'Incecco, M; Avanzini, C; Bossini, E; Ferroli, R Baldini; Bressan, E; Bencivenni, G; Dreucci, M; Fabbri, F L; Chiavassa, A; Frolov, V; Cicalo, C; Cifarelli, L; Gruttula, D De; Pasquale, S De; Doroud, K

    2012-01-01

    The Extreme Energy Events Project has been designed to join the scientific interest of a cosmic rays physics experiment with the enormous didactic potentiality deriving from letting it be carried out by high school students and teachers. After the initial phase, the experiment is starting to take data continuously, and the first interesting physics results have been obtained, demonstrating the validity of the idea of running a real physics investigation in these peculiar conditions. Here an overview of its structure and status is presented, together with some studies about detector performance and first physics results. (technical report)

  19. Balloon test project: Cosmic Ray Antimatter Calorimeter (CRAC)

    Science.gov (United States)

    Christy, J. C.; Dhenain, G.; Goret, P.; Jorand, J.; Masse, P.; Mestreau, P.; Petrou, N.; Robin, A.

    1984-01-01

    Cosmic ray observations from balloon flights are discussed. The cosmic ray antimatter calorimeter (CRAC) experiment attempts to measure the flux of antimatter in the 200-600 Mev/m energy range and the isotopes of light elements between 600 and 1,000 Mev/m.

  20. Ring energy selection and extra long straight sections for the Advanced Photon Source

    International Nuclear Information System (INIS)

    1987-04-01

    Recommended criteria are given for the performance of Advanced Photon Source (APS), taking into consideration undulator tunability criteria and their relationship to the storage ring energy and undulator gap, length of straight sections

  1. MORPION: a fast hardware processor for straight line finding in MWPC

    International Nuclear Information System (INIS)

    Mur, M.

    1980-02-01

    A fast hardware processor for straight line finding in MWPC has been built in Saclay and successfully operated in the NA3 experiment at CERN. We give the motivations to build this processor, and describe the hardware implementation of the line finding algorithm. Finally its use and performance in NA3 are described

  2. From MSM to heteroflexibilities: Non-exclusive straight male identities and their implications for HIV prevention and health promotion.

    Science.gov (United States)

    Carrillo, Héctor; Hoffman, Amanda

    2016-01-01

    This article examines the logics of self-identification among men who have same-sex desires and behaviours and consider themselves to be straight. We draw from interviews conducted in the USA with 100 straight-identified men who have same-sex desires and 40 partners of such men. Our data allow us to reject two misconceptions. One is the idea that these men are actually gay or bisexual but refuse to accept those identities. We argue instead that these men see themselves as straight and therefore it is important to understand what specifically they mean by that. The second misconception links straight-identified men who have same-sex desires and behaviours to the racialised discourse of the so-called down low (or 'DL') in the USA. While the DL typically is depicted as involving African American and Latino men, most of our participants are White. Moving beyond these misconceptions, we propose that health educators must acknowledge flexibilities in the definition of heterosexuality and use an expanded definition as a starting point to envision, together with these men, how to more effectively engage them in HIV prevention and health promotion.

  3. Aerodynamic shape optimization of non-straight small wind turbine blades

    International Nuclear Information System (INIS)

    Shen, Xin; Yang, Hong; Chen, Jinge; Zhu, Xiaocheng; Du, Zhaohui

    2016-01-01

    Graphical abstract: Small wind turbine blades with 3D stacking lines (sweep and bend) have been considered and analyzed with an optimization code based on the lifting surface method. The results indicated that the power capture and the rotor thrust can be improved with these more complex geometries. The starting behavior of the small wind turbines can be improved by the optimization of the blade chord and twist angle distribution. - Highlights: • The small wind turbine blade was optimized with non-straight shape. • Lifting surface method with free wake was used for aerodyanmic performace evaluation. • The non-straight shape can be used to increase energy production and decrease the thrust. • The energy production should be sacrificed in order to increase the starting behavior. - Abstract: Small wind turbines usually operate in sub-optimal wind conditions in order to satisfy the demand where it is needed. The aerodynamic performance of small horizontal axis wind turbines highly depends on the geometry. In the present study, the geometry of wind turbine blades are optimized not only in terms of the distribution of the chord and twist angle but also with 3-dimensional stacking line. As the blade with 3-dimensional stacking line is given sweep in the plan of rotation and dihedral in the plan containing the blade and rotor axis, the common used blade element momentum method can no longer provide accurate aerodynamic performance solution. A lifting surface method with free wake model is used as the aerodynamic model in the present work. The annual energy production and the starting performance are selected as optimization objective. The starting performance is evaluated based on blade element method. The optimization of the geometry of the non-straight wind turbine blades is carried out by using a micro-genetic algorithm. Results show that the wind turbine blades with properly designed 3-dimensional stacking line can increase the annual energy production and have

  4. Unzip instabilities: Straight to oscillatory transitions in the cutting of thin polymer sheets

    Science.gov (United States)

    Reis, P. M.; Kumar, A.; Shattuck, M. D.; Roman, B.

    2008-06-01

    We report an experimental investigation of the cutting of a thin brittle polymer sheet with a blunt tool. It was recently shown that the fracture path becomes oscillatory when the tool is much wider than the sheet thickness. Here we uncover two novel transitions from straight to oscillatory fracture by varying either the tilt angle of the tool or the speed of cutting, respectively. We denote these by angle and speed unzip instabilities and analyze them by quantifying both the dynamics of the crack tip and the final shapes of the fracture paths. Moreover, for the speed unzip instability, the straight crack lip obtained at low speeds exhibits out-of-plane buckling undulations (as opposed to being flat above the instability threshold) suggesting a transition from ductile to brittle fracture.

  5. Wind tunnel study of helical and straight-bladed vertical-axis wind turbine wakes

    Science.gov (United States)

    Bagheri, Maryam; Araya, Daniel

    2017-11-01

    It is hypothesized that blade curvature can serve as a passive means to control fluid entrainment and wake recovery in vertical-axis wind turbine (VAWT) arrays. We test this experimentally in a wind tunnel using two different VAWT configurations, one with straight blades and another with helical blades, keeping all other experimental parameters fixed. A small-scale, commercially available VAWT (15W max power) is used as the baseline wind tunnel model in each case. The commercial VAWT blades are replaced with either straight or helical blades that are 3D-printed extrusions of the same airfoil cross-section. Results from smoke flow visualization, three-component wake velocity measurements, and turbine power data are presented. These results give insight into the potential use of VAWTs with curved blades in utility-scale wind farms.

  6. Design, construction, characterization, and use of a detector to measure time of flight of cosmic rays

    Science.gov (United States)

    Araujo, A. C.; Felix, J.

    2017-01-01

    In the study of cosmic rays, measurements of time of flight and momentum have been used to identify incident particles from its physical properties, like mass. In this document we present the design, construction, characterization, and operation of a detector to measure time of flight of cosmic rays. The device is comprised of three small plates of plastic scintillator arranged in vertical straight line, coupled to one photomultiplier tube. The analogical output has been connected to a data acquisition system to obtain the number of digital pulses per millisecond. We present details of design, construction, operation, and preliminary results.

  7. Generation of gamma-ray streaming kernels through cylindrical ducts via Monte Carlo method

    International Nuclear Information System (INIS)

    Kim, Dong Su

    1992-02-01

    Since radiation streaming through penetrations is often the critical consideration in protection against exposure of personnel in a nuclear facility, it has been of great concern in radiation shielding design and analysis. Several methods have been developed and applied to the analysis of the radiation streaming in the past such as ray analysis method, single scattering method, albedo method, and Monte Carlo method. But they may be used for order-of-magnitude calculations and where sufficient margin is available, except for the Monte Carlo method which is accurate but requires a lot of computing time. This study developed a Monte Carlo method and constructed a data library of solutions using the Monte Carlo method for radiation streaming through a straight cylindrical duct in concrete walls of a broad, mono-directional, monoenergetic gamma-ray beam of unit intensity. The solution named as plane streaming kernel is the average dose rate at duct outlet and was evaluated for 20 source energies from 0 to 10 MeV, 36 source incident angles from 0 to 70 degrees, 5 duct radii from 10 to 30 cm, and 16 wall thicknesses from 0 to 100 cm. It was demonstrated that average dose rate due to an isotropic point source at arbitrary positions can be well approximated using the plane streaming kernel with acceptable error. Thus, the library of the plane streaming kernels can be used for the accurate and efficient analysis of radiation streaming through a straight cylindrical duct in concrete walls due to arbitrary distributions of gamma-ray sources

  8. Analysis of a Steerable Needle for Fine Needle Aspiration and Biopsy: Efficiency and Radiation Dose Compared With a Conventional Straight Needle.

    Science.gov (United States)

    Rutigliano, Sandra; Abraham, John A; Kenneally, Barry E; Zoga, Adam C; Nevalainen, Mika; Roedl, Johannes B

    Percutaneous computed tomography (CT)-guided needle biopsy has proven to be an efficacious method for sampling of many soft tissue lesions, especially deep-seated masses in the abdomen and pelvis. This study sought to test the potential for a novel steerable needle to improve localization and to reduce procedure duration and radiation dose compared with a conventional straight needle. A fresh, raw meat sample (lean bovine flank) was imbedded with cylindrical radiopaque and radiolucent obstacles designed to simulate vessels (radiolucent objects) and bones (radiopaque objects) on CT. A pit-containing olive (partially radiopaque) was imbedded beyond the obstacles to represent the target. Two sites on the surface of the meat were selected and marked to determine initial needle placement. Two radiologists with different levels of experience proceeded to position a straight needle and the steerable needle from each skin site to the target using CT guidance as efficiently as possible, avoiding the obstacles. The total positioning time, the number of CT scans required for positioning, and the number of repositioning events (partial withdrawal followed by advancement) were tracked for the straight and steerable needles. For the straight needle, total time to reach the target was 499 to 667 seconds (mean, 592 seconds); for the steerable needle, total time to reach the target was 281 to 343 seconds (mean, 309 seconds), on average, 48% lower. The number of CT scans needed for needle positioning averaged 6.25 for the straight needle and 3.5 for the steerable needle, which is 44% lower. Repositioning events (withdrawing and readvancing the needle) ranged from 3 to 10 for the straight needle (mean, 6.5) and 0 for the steerable needle. Using an in vitro model embedded with obstacles, the steerable needle performed better than a straight needle with regard to procedure time, needle repositioning events, and CT scans required for placement.

  9. Evaluation of noise limits to improve image processing in soft X-ray projection microscopy.

    Science.gov (United States)

    Jamsranjav, Erdenetogtokh; Kuge, Kenichi; Ito, Atsushi; Kinjo, Yasuhito; Shiina, Tatsuo

    2017-03-03

    Soft X-ray microscopy has been developed for high resolution imaging of hydrated biological specimens due to the availability of water window region. In particular, a projection type microscopy has advantages in wide viewing area, easy zooming function and easy extensibility to computed tomography (CT). The blur of projection image due to the Fresnel diffraction of X-rays, which eventually reduces spatial resolution, could be corrected by an iteration procedure, i.e., repetition of Fresnel and inverse Fresnel transformations. However, it was found that the correction is not enough to be effective for all images, especially for images with low contrast. In order to improve the effectiveness of image correction by computer processing, we in this study evaluated the influence of background noise in the iteration procedure through a simulation study. In the study, images of model specimen with known morphology were used as a substitute for the chromosome images, one of the targets of our microscope. Under the condition that artificial noise was distributed on the images randomly, we introduced two different parameters to evaluate noise effects according to each situation where the iteration procedure was not successful, and proposed an upper limit of the noise within which the effective iteration procedure for the chromosome images was possible. The study indicated that applying the new simulation and noise evaluation method was useful for image processing where background noises cannot be ignored compared with specimen images.

  10. Straight A's: Public Education Policy and Progress. Volume 12, Number 7

    Science.gov (United States)

    Amos, Jason, Ed.

    2012-01-01

    "Straight A's: Public Education Policy and Progress" is a biweekly newsletter that focuses on education news and events both in Washington, DC and around the country. The following articles are included in this issue: (1) Problems Down the Road: House Passes Congressional Budget Resolutions, Sets Overall Spending Cap at $19 Billion Below Senate;…

  11. A Program Review of a Middle School Gay-Straight Alliance Club

    Science.gov (United States)

    Quasha, Scott; McCabe, Paul C.; Ortiz, Samuel O.

    2014-01-01

    This program review examined a middle school Gay-Straight Alliance (GSA) club within a northeastern suburban school situated in a large metropolitan area. The GSA was the first in the region to start exclusively in a standalone middle school. The review was accomplished through a staff survey comparing school climates for lesbian, gay, bisexual,…

  12. Straight A's: Public Education Policy and Progress. Volume 6, Number 2

    Science.gov (United States)

    Amos, Jason, Ed.

    2006-01-01

    "Straight A's: Public Education Policy and Progress" is a biweekly newsletter that focuses on education news and events both in Washington, DC and around the country. The following articles are included in this issue: (1) State of American Business: U.S. Chamber of Commerce Says U.S. Could Face a "Severe Worker Shortage" Unless…

  13. Parallel Hough Transform-Based Straight Line Detection and Its FPGA Implementation in Embedded Vision

    Directory of Open Access Journals (Sweden)

    Nam Ling

    2013-07-01

    Full Text Available Hough Transform has been widely used for straight line detection in low-definition and still images, but it suffers from execution time and resource requirements. Field Programmable Gate Arrays (FPGA provide a competitive alternative for hardware acceleration to reap tremendous computing performance. In this paper, we propose a novel parallel Hough Transform (PHT and FPGA architecture-associated framework for real-time straight line detection in high-definition videos. A resource-optimized Canny edge detection method with enhanced non-maximum suppression conditions is presented to suppress most possible false edges and obtain more accurate candidate edge pixels for subsequent accelerated computation. Then, a novel PHT algorithm exploiting spatial angle-level parallelism is proposed to upgrade computational accuracy by improving the minimum computational step. Moreover, the FPGA based multi-level pipelined PHT architecture optimized by spatial parallelism ensures real-time computation for 1,024 × 768 resolution videos without any off-chip memory consumption. This framework is evaluated on ALTERA DE2-115 FPGA evaluation platform at a maximum frequency of 200 MHz, and it can calculate straight line parameters in 15.59 ms on the average for one frame. Qualitative and quantitative evaluation results have validated the system performance regarding data throughput, memory bandwidth, resource, speed and robustness.

  14. Parallel Hough Transform-based straight line detection and its FPGA implementation in embedded vision.

    Science.gov (United States)

    Lu, Xiaofeng; Song, Li; Shen, Sumin; He, Kang; Yu, Songyu; Ling, Nam

    2013-07-17

    Hough Transform has been widely used for straight line detection in low-definition and still images, but it suffers from execution time and resource requirements. Field Programmable Gate Arrays (FPGA) provide a competitive alternative for hardware acceleration to reap tremendous computing performance. In this paper, we propose a novel parallel Hough Transform (PHT) and FPGA architecture-associated framework for real-time straight line detection in high-definition videos. A resource-optimized Canny edge detection method with enhanced non-maximum suppression conditions is presented to suppress most possible false edges and obtain more accurate candidate edge pixels for subsequent accelerated computation. Then, a novel PHT algorithm exploiting spatial angle-level parallelism is proposed to upgrade computational accuracy by improving the minimum computational step. Moreover, the FPGA based multi-level pipelined PHT architecture optimized by spatial parallelism ensures real-time computation for 1,024 × 768 resolution videos without any off-chip memory consumption. This framework is evaluated on ALTERA DE2-115 FPGA evaluation platform at a maximum frequency of 200 MHz, and it can calculate straight line parameters in 15.59 ms on the average for one frame. Qualitative and quantitative evaluation results have validated the system performance regarding data throughput, memory bandwidth, resource, speed and robustness.

  15. Calculation of gamma ray exposure rates from uranium ore bodies

    International Nuclear Information System (INIS)

    Thomson, J.E.; Wilson, O.J.

    1980-02-01

    The planning of operations associated with uranium mines often requires that estimates be made of the exposure rates from various ore bodies. A straight-forward method of calculating the exposure rate from an arbitrarily shaped body is presented. Parameters for the calculation are evaluated under the assumption of secular equilibrium of uranium with its daughters and that the uranium is uniformly distributed throughout an average soil mixture. The spectral distribution of the emitted gamma rays and the effect of air attenuation are discussed. Worked examples are given of typical situations encountered in uranium mines

  16. Optimization of Straight Cylindrical Turning Using Artificial Bee Colony (ABC) Algorithm

    Science.gov (United States)

    Prasanth, Rajanampalli Seshasai Srinivasa; Hans Raj, Kandikonda

    2017-04-01

    Artificial bee colony (ABC) algorithm, that mimics the intelligent foraging behavior of honey bees, is increasingly gaining acceptance in the field of process optimization, as it is capable of handling nonlinearity, complexity and uncertainty. Straight cylindrical turning is a complex and nonlinear machining process which involves the selection of appropriate cutting parameters that affect the quality of the workpiece. This paper presents the estimation of optimal cutting parameters of the straight cylindrical turning process using the ABC algorithm. The ABC algorithm is first tested on four benchmark problems of numerical optimization and its performance is compared with genetic algorithm (GA) and ant colony optimization (ACO) algorithm. Results indicate that, the rate of convergence of ABC algorithm is better than GA and ACO. Then, the ABC algorithm is used to predict optimal cutting parameters such as cutting speed, feed rate, depth of cut and tool nose radius to achieve good surface finish. Results indicate that, the ABC algorithm estimated a comparable surface finish when compared with real coded genetic algorithm and differential evolution algorithm.

  17. Lifetime estimation of a time projection chamber x-ray polarimeter

    Science.gov (United States)

    Hill, Joanne E.; Black, J. Kevin; Brieda, Lubos; Dickens, Patsy L.; Montt de Garcia, Kristina; Hawk, Douglas L.; Hayato, Asami; Jahoda, Keith; Mohammed, Jelila

    2013-09-01

    The Gravity and Extreme Magnetism Small Explorer (GEMS) X-ray polarimeter Instrument (XPI) was designed to measure the polarization of 23 sources over the course of its 9 month mission. The XPI design consists of two telescopes each with a polarimeter assembly at the focus of a grazing incidence mirror. To make sensitive polarization measurements the GEMS Polarimeter Assembly (PA) employed a gas detection system based on a Time Projection Chamber (TPC) technique. Gas detectors are inherently at risk of degraded performance arising from contamination from outgassing of internal detector components or due to loss of gas. This paper describes the design and the materials used to build a prototype of the flight polarimeter with the required GEMS lifetime. We report the results from outgassing measurements of the polarimeter subassemblies and assemblies, enclosure seal tests, life tests, and performance tests that demonstrate that the GEMS lifetime is achievable. Finally we report performance measurements and the lifetime enhancement from the use of a getter.

  18. Straight A's: Public Education Policy and Progress. Volume 12, Number 9

    Science.gov (United States)

    Amos, Jason, Ed.

    2012-01-01

    "Straight A's: Public Education Policy and Progress" is a biweekly newsletter that focuses on education news and events both in Washington, DC and around the country. The following articles are included in this issue: (1) You Take the High Road and I'll Take the Low Road: As Appropriations Process Begins, Different Spending Approaches Likely to…

  19. I20; the Versatile X-ray Absorption spectroscopy beamline at Diamond Light Source

    International Nuclear Information System (INIS)

    Diaz-Moreno, S; Hayama, S; Amboage, M; Freeman, A; Sutter, J; Duller, G

    2009-01-01

    The Versatile Spectroscopy beamline at Diamond Light Source, I20, is currently under construction and aims to begin operation in late 2009 and early 2010. The beamline aims to cover applications from physics, chemistry and biology through materials, environmental and geological science. Three very distinctive modes of operation will be offered at the beamline: scanning X-ray Absorption spectroscopy (XAS), XAS in dispersive mode, and X-ray emission spectroscopy (XES). To achieve this, the beamline has been designed around two independent experimental end-stations operating from a pair of canted wigglers located in a 5m diamond straight section. One branch of the beamline will deliver monochromatic x-ray radiation of high spectral purity to one of the experimental hutches, whilst the other branch will constitute an energy dispersive spectrometer. The novel design of the beamline allows both branches to operate simultaneously.

  20. 3D computed tomography using a microfocus X-ray source: Analysis of artifact formation in the reconstructed images using simulated as well as experimental projection data

    International Nuclear Information System (INIS)

    Krimmel, S.; Stephan, J.; Baumann, J.

    2005-01-01

    The scope of this contribution is to identify and to quantify the influence of different parameters on the formation of image artifacts in X-ray computed tomography (CT) resulting for example, from beam hardening or from partial lack of information using 3D cone beam CT. In general, the reconstructed image quality depends on a number of acquisition parameters concerning the X-ray source (e.g. X-ray spectrum), the geometrical setup (e.g. cone beam angle), the sample properties (e.g. absorption characteristics) and the detector properties. While it is difficult to distinguish the influence of different effects clearly in experimental projection data, they can be selected individually with the help of simulated projection data by varying the parameter set. The reconstruction of the 3D data set is performed with the filtered back projection algorithm according to Feldkamp, Davis and Kress for experimental as well as for simulated projection data. The experimental data are recorded with an industrial microfocus CT system which features a focal spot size of a few micrometers and uses a digital flat panel detector for data acquisition

  1. Discrete curved ray-tracing method for radiative transfer in an absorbing-emitting semitransparent slab with variable spatial refractive index

    International Nuclear Information System (INIS)

    Liu, L.H.

    2004-01-01

    A discrete curved ray-tracing method is developed to analyze the radiative transfer in one-dimensional absorbing-emitting semitransparent slab with variable spatial refractive index. The curved ray trajectory is locally treated as straight line and the complicated and time-consuming computation of ray trajectory is cut down. A problem of radiative equilibrium with linear variable spatial refractive index is taken as an example to examine the accuracy of the proposed method. The temperature distributions are determined by the proposed method and compared with the data in references, which are obtained by other different methods. The results show that the discrete curved ray-tracing method has a good accuracy in solving the radiative transfer in one-dimensional semitransparent slab with variable spatial refractive index

  2. Muskuloskeletal radiography as a specialty. A quality improvement project on positioning of musculoskeletal x-rays with a multimethodology and multidisciplinary approach

    DEFF Research Database (Denmark)

    Jensen, Janni; Torfing, Trine

    treatment and/or unfavorable outcome for the patient. Guidelines developed by “European Guidelines on Quality Criteria for Diagnostic Radiographic Images” provide quality assessment tools regarding the technical aspect of x-rays (i.e. noise and resolution). One could argue what the quality of a perfectly......, i.e. the radiographers working with muskuloskeletal x-rays are specialized within this field. The primary purposes of this project are to perform continuous quantitative quality assessment and improvement of positioning of muskuloskeletal x-rays. Methods It has not yet been possible to find any...... of muskuloskeletal x-rays held by a radiologist, a reporting radiographer and an orthopedic surgeon, all from OUH • Radiographers are offered one-hour individual sessions with a reporting radiographer reviewing their own X-rays discussing positioning and pathology focusing on the association between positioning...

  3. X-ray topographic method of investigation of phase objects

    International Nuclear Information System (INIS)

    Levonyan, L.V.

    2001-01-01

    The intensity distribution of the monochromatized synchrotron radiation transmitting through the phase object and crystal-analyzer in Laue geometry is considered. It is shown that the local angular deviation of the incident radiation caused by the refraction on structural inhomogeneities of the object under investigation is directly transferred to the X-ray topographic image. In the absence of the phase object the latter consists of parallel straight fringes with a slowly decreasing period. The presence of the phase object changes the shape and period of fringes. The influence of the spatial and temporal coherence on the image is discussed. 5 refs

  4. The female geriatric proximal humeral fracture: protagonist for straight antegrade nailing?

    Science.gov (United States)

    Lindtner, Richard A; Kralinger, Franz S; Kapferer, Sebastian; Hengg, Clemens; Wambacher, Markus; Euler, Simon A

    2017-10-01

    Straight antegrade humeral nailing (SAHN) has become a standard technique for the surgical fixation of proximal humeral fractures, which predominantly affect elderly females. The nail's proximal anchoring point has been demonstrated to be critical to ensure reliable fixation in osteoporotic bone and to prevent iatrogenic damage to the superior rotator cuff bony insertion. Anatomical variations of the proximal humerus, however, may preclude satisfactory anchoring of the nail's proximal end and may bare the risk of rotator cuff violation, even though the nail is inserted as recommended. The aim of this study was to evaluate the anatomical suitability of proximal humeri of geriatric females aged 75 years and older for SAHN. Specifically, we sought to assess the proportion of humeri not anatomically amenable to SAHN for proximal humeral fracture. A total of 303 proximal humeri of 241 females aged 75 years and older (mean age 84.5 ± 5.0 years; range 75-102 years) were analyzed for this study. Multiplanar two-dimensional reformations (true ap, true lateral, and axial) were reconstructed from shoulder computed tomography (CT) data sets. The straight antegrade nail's ideal entry point, "critical point" (CP), and critical distance (CD; distance between ideal entry point and CP) were determined. The rate of proximal humeri not anatomically suitable for SAHN (critical type) was assessed regarding proximal reaming diameters of currently available straight antegrade humeral nails. Overall, 35.6% (108/303) of all proximal humeri were found to be "critical types" (CD straight antegrade nails currently in use. Moreover, 43.2% (131/303) of the humeri were considered "critical types" with regard to the alternatively used larger proximal reaming diameter of 11.5 mm. Mean CD was 9.0 ± 1.7 mm (range 3.5-13.5 mm) and did not correlate with age (r = -0.04, P = 0.54). No significant differences in CD and rate of "critical types" were found between left and right humeri

  5. Numerical investigation on the flow and power of small-sized multi-bladed straight Darrieus wind turbine

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Straight Darrieus wind turbine has attractive characteristics such as the ability to accept wind from random direction and easy installation and maintenance. But its aerodynamic performance is very complicated, especially for the existence of dynamic stall. How to get better aerodynamic performance arouses lots of interests in the design procedure of a straight Darrieus wind turbine. In this paper, mainly the effects of number of blades and tip speed ratio are discussed. Based on the numerical investigation, an assumed asymmetric straight Darrieus wind turbine is proposed to improve the averaged power coefficient. As to the numerical method, the flow around the turbine is simulated by solving the 2D unsteady Navier-Stokes equation combined with continuous equation. The time marching method on a body-fitted coordinate system based on MAC (Marker-and-Cell) method is used. O-type grid is generated for the whole calculation domain. The characteristics of tangential and normal force are discussed related with dynamic stall of the blade. Averaged power coefficient per period of rotating is calculated to evaluate the eligibility of the turbine.

  6. Specialized software utilities for gamma ray spectrometry. Final report of a co-ordinated research project 1996-2000

    International Nuclear Information System (INIS)

    2002-03-01

    A Co-ordinated Research Project (CRP) on Software Utilities for Gamma Ray Spectrometry was initiated by the International Atomic Energy Agency in 1996 for a three year period. In the CRP several basic applications of nuclear data handling were assayed which also dealt with the development of PC computer codes for various spectrometric purposes. The CRP produced several software packages: for the analysis of low level NaI spectra; user controlled analysis of gamma ray spectra from HPGe detectors; a set of routines for the definition of the detector resolution function and for the unfolding of experimental annihilation spectra; a program for the generation of gamma ray libraries for specific applications; a program to calculate true coincidence corrections; a program to calculate full-energy peak efficiency calibration curve for homogenous cylindrical sample geometries including self-attenuation correction; and a program for the library driven analysis of gamma ray spectra and for the quantification of radionuclide content in samples. In addition, the CRP addressed problems of the analysis of naturally occurring radioactive soil material gamma ray spectra, questions of quality assurance and quality control in gamma ray spectrometry, and verification of the expert system SHAMAN for the analysis of air filter spectra obtained within the framework of the Comprehensive Nuclear Test Ban Treaty. This TECDOC contains 10 presentations delivered at the meeting with the description of the software developed. Each of the papers has been indexed separately

  7. Movement of the sacroiliac joint during the Active Straight Leg Raise test in patients with long-lasting severe sacroiliac joint pain.

    Science.gov (United States)

    Kibsgård, Thomas J; Röhrl, Stephan M; Røise, Olav; Sturesson, Bengt; Stuge, Britt

    2017-08-01

    The Active Straight Leg Raise is a functional test used in the assessment of pelvic girdle pain, and has shown to have good validity, reliability and responsiveness. The Active Straight Leg Raise is considered to examine the patients' ability to transfer load through the pelvis. It has been hypothesized that patients with pelvic girdle pain lack the ability to stabilize the pelvic girdle, probably due to instability or increased movement of the sacroiliac joint. This study examines the movement of the sacroiliac joints during the Active Straight Leg Raise in patients with pelvic girdle pain. Tantalum markers were inserted in the dorsal sacrum and ilium of 12 patients with long-lasting pelvic girdle pain scheduled for sacroiliac joint fusion surgery. Two to three weeks later movement of the sacroiliac joints during the Active Straight Leg Raise was measured with radiostereometric analysis. Small movements were detected. There was larger movement of the sacroiliac joint of the rested leg's sacroiliac joint compared to the lifted leg's side. A mean backward rotation of 0.8° and inward tilt of 0.3° were seen in the rested leg's sacroiliac joint. The movements of the sacroiliac joints during the Active Straight Leg Raise are small. There was a small backward rotation of the innominate bone relative to sacrum on the rested leg's side. Our findings contradict an earlier understanding that a forward rotation of the lifted leg's innominate occur while performing the Active Straight Leg Raise. Copyright © 2017. Published by Elsevier Ltd.

  8. High School Gay-Straight Alliances (GSAs) and Young Adult Well-Being: An Examination of GSA Presence, Participation, and Perceived Effectiveness

    Science.gov (United States)

    Toomey, Russell B.; Ryan, Caitlin; Diaz, Rafael M.; Russell, Stephen T.

    2011-01-01

    Gay-Straight Alliances (GSAs) are student-led, school-based clubs that aim to provide a safe environment in the school context for lesbian, gay, bisexual, and transgender (LGBT) students, as well as their straight allies. The present study examines the potential for GSAs to support positive youth development and to reduce associations among…

  9. Penerapan Metode Straight Selection pada Sistem Parkir Universitas Bina Nusantara

    OpenAIRE

    Maharani, Mega; Merlina, Nita

    2014-01-01

    The parking information System is designed to develop the current system that has been employed at BINA NUSANTARA University. Currently, the parking system is limited only recording the police number and they are still manually looking for the available parking area. The system implements straight selection sorting data method, also known as the smallest number search method to determine the available parking location. Parking area will be automatically printed at parking ticket, thus the dri...

  10. Advantages of Direct Insertion of a Straight Probe Without a Guide Tube During Anterior Odontoid Screw Fixation of Odontoid Fractures.

    Science.gov (United States)

    Park, Jin Hoon; Kang, Dong-Ho; Lee, Moon Kyu; Yoo, Byoungwoo; Jung, Sang Ku; Hwang, Soo-Hyun; Kim, Jeoung Hee; Oh, Sunkyu; Lee, Eun Jung; Jeon, Sang Ryong; Roh, Sung Woo; Rhim, Seung Chul

    2016-05-01

    A retrospective cohort study. The aim of this study was to compare the anterior odontoid screw fixation (AOSF) with a guide tube or with a straight probe. AOSF associates with several complications, including malpositioning, fixation loss, and screw breakage. Screw pull-out from the C2 body is the most common complication. All consecutive patients with type II or rostral shallow type III odontoid fractures who underwent AOSFs during the study period were enrolled retrospectively. The guide-tube AOSF method followed the standard published method except C3 body and C2-3 disc annulus rimming was omitted to prevent disc injury; instead, the guide tube was anchored at the anterior inferior C2 vertebra corner. After 2 screw pull-outs, the guide-tube cohort was analyzed to identify the cause of instrument failure. Thereafter, the straight-probe method was developed. A guide tube was not used. A small pilot hole was made on the most anterior side of the inferior endplate, followed by insertion of a 2.5 mm straight probe through the C2 body. Non-union and instrument failure rates and screw-direction angles of the guide-tube and straight-probe groups were recorded. The guide-tube group (n = 13) had 2 screw pull-outs and 1 non-union. The straight-probe group (n = 8) had no complications and significantly larger screw-direction angles than the guide-tube group (60.5 ± 4.63 vs. 54.8 ± 3.82 degrees; P = 0.047). Straight-probe AOSF yielded larger direction angles without injuring bone and disc. Complications were absent. The procedure was easier than guide-tube AOSF and assured sufficient engagement, even in horizontal fracture orientation cases. 3.

  11. Straight vegetable oil use in Micro-Gas Turbines: System adaptation and testing

    International Nuclear Information System (INIS)

    Prussi, M.; Chiaramonti, D.; Riccio, G.; Martelli, F.; Pari, L.

    2012-01-01

    Highlights: → The possibility to feed a Micro Gas Turbine with Straight Vegetable Oil (SVO) has been investigated. → Correlative analysis and CFD were used to model the effect of SVO characteristics on atomization and evaporation. → Minor modifications to a the commercial MGT were adopted. → Measured power output and specific fuel consumption were close to standard fuel, taking into account the LHV of SVO. → Emissions were higher than for standard fossil fuel but strongly affected by SVO temperature. -- Abstract: The aim of this research work is to investigate the use of straight vegetable sunflower oil (SFO), a liquid biofuel, in a Micro-Gas Turbine (MGT). Compared to conventional diesel engines, micro-gas turbines represent a very reliable, clean and performing small scale cogeneration technology. Commercial gas turbines have already been tested with unconventional fuels, such as biomass derived fuels; however, research work on using Straight Vegetable Oil (SVO) as fuel in MGTs are really scarce. The chemical and physical characteristics of SVO are different from fossil diesel oil and rather far from the common technical specifications for gas turbine liquid fuels, not only in terms of kinematic viscosity and Lower Heating Value, but also as regards other issues as contaminant levels and composition, fuel cold properties, ignition properties, etc. Therefore, particular attention has to be given to the atomization and evaporation phases, as these are the most critical steps to achieve stable and efficient long term operation. An analysis based on numerical correlations available from literature was initially adopted for the analysis of the atomization process, supported by CFD modeling to qualitatively investigate the flow pattern. Control parameters were revised and set so to produce a sunflower oil spray having evaporation time comparable to diesel, and minor adaptations to the fuel line were designed and installed on the MGT. Tests with blends and

  12. "Not Going Away": Approaches Used by Students, Faculty, and Staff Members to Create Gay-Straight Alliances at Three Religiously Affiliated Universities

    Science.gov (United States)

    McEntarfer, Heather Killelea

    2011-01-01

    This qualitative study examines the processes of forming gay-straight alliances at three religiously affiliated institutions of higher education. Using the lens of Social Movement Theory (SMT), this paper presents the methods and approaches used when advocates of gay-straight alliances at these institutions encountered resistance from…

  13. The MARIACHI Project: Mixed Apparatus for Radio Investigation of Atmospheric Cosmic Rays of High Ionization

    Science.gov (United States)

    Inglis, M. D.; Takai, H.; Warasia, R.; Sundermier, J.

    2005-12-01

    Extreme Energy Cosmic Rays are nuclei that have been accelerated to kinetic energies in excess of 1020 eV. Where do they come from? How are they produced? Are they survivors of the early universe? Are they remnants of supernovas? MARIACHI, a unique collaboration between scientists, physics teachers and students, is an innovative technique that allows us to detect and study them. The Experiment MARIACHI is a unique research experiment that seeks the detection of extreme energy cosmic rays (EECRs), with E >1020 eV. It is an exciting project with many aspects: Research: It investigates an unconventional way of detecting EECRs based upon a method successfully used to detect meteors entering the upper atmosphere. The method was developed by planetary astronomers listening to radio signals reflected off the ionization trail. MARIACHI seeks to listen to TV signals reflected off the ionization trail of an EECR. The unique experiment topology will also permit the study of meteors, exotic forms of lightning, and atmospheric science. Computing and Technology: It uses radio detection stations, along with mini shower arrays hooked up to GPS clocks. Teachers and students build the arrays. It implements the Internet and the GRID as means of communication, data transfer, data processing, and for hosting a public educational outreach web site. Outreach and Education: It is an open research project with the active participation of a wide audience of astronomers, physicists, college professors, high school teachers and students. Groups representing high schools, community colleges and universities all collaborate in the project. The excitement of a real experiment motivates the science and technology classroom, and incorporates several high school physical science topics along with material from other disciplines such as astronomy, electronics, radio, optics.

  14. The MEL-X project at the Lawrence Livermore National Laboratory: a mirror-based delay line for x-rays

    Science.gov (United States)

    Pardini, Tom; Hill, Randy; Decker, Todd; Alameda, Jennifer; Soufli, Regina; Aquila, Andy; Guillet, Serge; Boutet, Sébastien; Hau-Riege, Stefan P.

    2015-09-01

    At the Lawrence Livermore National Laboratory (LLNL) in collaboration with the Linac Coherent Light Source (LCLS) we are developing a mirror-based delay line for x-rays (MEL-X) to enable x-ray pump/x-ray probe experiments at Free Electron Lasers (XFELs). The goal of this project is the development and deployment of a proof-of-principle delay line featuring coated x-ray optics. The four-mirror design of the MEL-X is motivated by the need for ease of alignment and use. In order to simplify the overlap of the pump and the probe beam after each delay time change, a scheme involving super-polished rails and mirror-to-motor decoupling has been adopted. The MEL-X, used in combination with a bright pulsed source like LCLS, features a capability for a high intensity pump beam. Its Iridium coating allows it to work at hard x-ray energies all the way up to 9 keV, with a probe beam transmission of 35% up to 8keV, and 14% at 9keV. The delay time can be tailored to each particular experiment, with a nominal range of 70 - 350 fs for this prototype. The MEL-X, combined with established techniques such as x-ray diffraction, absorption or emission, could provide new insights on ultra-fast transitions in highly excited states of matter.

  15. A 3D Kinematic Measurement of Knee Prosthesis Using X-ray Projection Images

    Science.gov (United States)

    Hirokawa, Shunji; Ariyoshi, Shogo; Hossain, Mohammad Abrar

    We have developed a technique for estimating 3D motion of knee prosthesis from its 2D perspective projections. As Fourier descriptors were used for compact representation of library templates and contours extracted from the prosthetic X-ray images, the entire silhouette contour of each prosthetic component was required. This caused such a problem as our algorithm did not function when the silhouettes of tibio and femoral components overlapped with each other. Here we planned a novel method to overcome it; which was processed in two steps. First, the missing part of silhouette contour due to overlap was interpolated using a free-formed curvature such as Bezier. Then the first step position/orientation estimation was performed. In the next step, a clipping window was set in the projective coordinate so as to separate the overlapped silhouette drawn using the first step estimates. After that the localized library whose templates were clipped in shape was prepared and the second step estimation was performed. Computer model simulation demonstrated sufficient accuracies of position/orientation estimation even for overlapped silhouettes; equivalent to those without overlap.

  16. INTERRAD - inductive terawatt X-ray generator (project)

    Energy Technology Data Exchange (ETDEWEB)

    Popkov, N F; Pikar` , A S; Kargin, V I; Ryaslov, E A; Lyubomirskij, A G [All-Russian Scientific Research Inst. of Experimental Physics, Sarov (Russian Federation)

    1997-12-31

    The results are given of the development and experimental research of explosive electron beam accelerator circuits powered by magneto-cumulative generators forming the current pulse, using explosive plasma opening switches. The conceptual lay-out of inductive terawatt X-ray generators powered by EMGs is proposed. The calculation results of the terawatt x-ray generator including the load placed in a special bunker are presented. Analyzed are the losses at the stage of the HE energy conversion into that of the magnetic fields, those occur ing in transmission along the high-voltage cable line, as well as the processes developing in the plasma opening switches. (author). 2 figs., 6 refs.

  17. Straight-bladed Darrieus wind turbines - A protagonist's view

    Science.gov (United States)

    Migliore, P. G.

    The technology development and market penetration of Darrieus and propeller-type wind turbines is addressed. Important characteristics of competing configurations are compared, and it is claimed that aerodynamic efficiency is not a distinguishing feature. Advantages of the Darrieus machine include omni-directionality and self-limitation, but propeller types require less rotor length per unit swept area. It is argued that the straight-bladed Darrieus is much simpler than the curved-bladed and should be capable of comparable aerodynamic efficiency. Some of the problems of structural design, as well as blade induced drag losses and support-arm counter torque, diminish rapidly as machine size is increased. Taper ratio has similar beneficial effects.

  18. Evaluating the Subjective Straight Ahead Before and After Spaceflight

    Science.gov (United States)

    Campbell, D. J.; Wood, S. J.; Reschke, M. F.; Clement, G.

    2017-01-01

    This joint European Space Agency (ESA) - NASA study will address adaptive changes in spatial orientation related to the subjective straight ahead and the use of a vibrotactile sensory aid to reduce perceptual errors. The study will be conducted before and after long duration expeditions to the International Space Station (ISS) to examine how spatial processing of target location is altered following exposure to microgravity. This study addresses the sensorimotor research gap to "determine the changes in sensorimotor function over the course of a mission and during recovery after landing."

  19. Evaluation of the predictive capacity of DNA variants associated with straight hair in Europeans.

    Science.gov (United States)

    Pośpiech, Ewelina; Karłowska-Pik, Joanna; Marcińska, Magdalena; Abidi, Sarah; Andersen, Jeppe Dyrberg; Berge, Margreet van den; Carracedo, Ángel; Eduardoff, Mayra; Freire-Aradas, Ana; Morling, Niels; Sijen, Titia; Skowron, Małgorzata; Söchtig, Jens; Syndercombe-Court, Denise; Weiler, Natalie; Schneider, Peter M; Ballard, David; Børsting, Claus; Parson, Walther; Phillips, Chris; Branicki, Wojciech

    2015-11-01

    DNA-based prediction of hair morphology, defined as straight, curly or wavy hair, could contribute to an improved description of an unknown offender and allow more accurate forensic reconstructions of physical appearance in the field of forensic DNA phenotyping. Differences in scalp hair morphology are significant at the worldwide scale and within Europe. The only genome-wide association study made to date revealed the Trichohyalin gene (TCHH) to be significantly associated with hair morphology in Europeans and reported weaker associations for WNT10A and FRAS1 genes. We conducted a study that centered on six SNPs located in these three genes with a sample of 528 individuals from Poland. The predictive capacity of the candidate DNA variants was evaluated using logistic regression; classification and regression trees; and neural networks, by applying a 10-fold cross validation procedure. Additionally, an independent test set of 142 males from six European populations was used to verify performance of the developed prediction models. Our study confirmed association of rs11803731 (TCHH), rs7349332 (WNT10A) and rs1268789 (FRAS1) SNPs with hair morphology. The combined genotype risk score for straight hair had an odds ratio of 2.7 and these predictors explained ∼ 8.2% of the total variance. The selected three SNPs were found to predict straight hair with a high sensitivity but low specificity when a 10-fold cross validation procedure was applied and the best results were obtained using the neural networks approach (AUC=0.688, sensitivity=91.2%, specificity=23.0%). Application of the neural networks model with 65% probability threshold on an additional test set gave high sensitivity (81.4%) and improved specificity (50.0%) with a total of 78.7% correct calls, but a high non-classification rate (66.9%). The combined TTGGGG SNP genotype for rs11803731, rs7349332, rs1268789 (European frequency=4.5%) of all six straight hair-associated alleles was identified as the best

  20. Conversion of straight-run gas-condensate benzenes into high- octane gasolines based on modified ZSM-5 zeolites

    International Nuclear Information System (INIS)

    Erofeev, V; Reschetilowski, V; Khomajakov, I; Egorova, L; Volgina, T; Tatarkina, A

    2014-01-01

    This paper describes the conversion of straight-run benzene of gas condensate into high-octane gasoline based on zeolite catalyst ZSM-5, modified in binary system oxide- based Sn (III) and Bi (III). It was defined that the introduction of the binary system oxide-based Sn(III) and Bi (III) into the basic zeolite results in the 2-fold increase of its catalytic activity.High-octane gasoline converted from straight-run benzene is characterized by a low benzol content in comparison to the high-octane benzenes produced during the catalytic reforming

  1. A novel low-temperature chemical solution route for straight and dendrite-like ZnO nanostructures

    International Nuclear Information System (INIS)

    Zhang Hui; Du Ning; Wu Jianbo; Ma, Xiangyang; Yang Deren; Zhang Xiaobin; Yang Zhiqing

    2007-01-01

    The straight and dendrite-like growths of ZnO have been completely and simply controlled by the status of ZnO seed instead of surfactant, template, oriented attachment, and ZnO buffer layer on the substrate in the chemical reaction synthesis of ZnO nanostructures. The monodisperse ZnO seeds, which are prepared by in situ quickly injecting the cool mixed zinc acetate and potassium hydrate ethanol solution into the hot matrix aqueous solution of zinc nitrate hydrate and diethylenetriamine at 95 deg. C, improve the straight growth and lots of uniform, straight, and single-crystalline ZnO nanorods with about 20-30 nm in diameter and 300 nm in length are achieved. While, the aggregated ZnO seeds, which are prepared by dropwise adding potassium hydrate ethanol solution into zinc acetate ethanol solution at 60 deg. C for 3 h, result in the dendrite-like growth and the bur-like ZnO nanostructures consisting of hundreds of nanorods with about 30-50 nm in diameter and several micrometers in length are formed. Furthermore, the approach presented here provides a simple, low-cost, environmental-friendly and high efficiency route to synthesize the high quality ZnO nanorods and bur-like ZnO nanostructures

  2. ICIT contribution to JET gamma-ray diagnostics enhancement

    International Nuclear Information System (INIS)

    Soare, S.; Curuia, M.; Zoita, V.

    2010-01-01

    Full text: Gamma-ray emission of tokamak plasmas is the result of the interaction of fast ions (fusion reaction products, including alpha particles, NBI ions, ICRH-accelerated ions) with main plasma impurities (e.g., carbon, beryllium). Gamma-ray diagnostics involve both gamma-ray imaging (cameras) and gamma-ray spectrometry (spectrometers). For the JET tokamak, gamma-ray diagnostics have been used to provide information on the characteristics of the fast ion population in plasmas. Two gamma-ray diagnostics enhancements project have been launched by JET and the MEdC/EURATOM Association has agreed to lead both of them with ICIT as projects leader. (authors)

  3. THE SPECTACULAR RADIO-NEAR-IR-X-RAY JET OF 3C 111: THE X-RAY EMISSION MECHANISM AND JET KINEMATICS

    Energy Technology Data Exchange (ETDEWEB)

    Clautice, Devon; Perlman, Eric S. [Department of Physics and Space Sciences, Florida Institute of Technology, 150 W. University Boulevard, Melbourne, FL 32901 (United States); Georganopoulos, Markos [Department of Physics, University of Maryland—Baltimore County, 1000 Hilltop Circle, Baltimore, MD 21250 (United States); Lister, Matthew L.; Hogan, Brandon [Department of Physics and Astronomy, Purdue University, 525 Northwestern Avenue, West Lafayette, IN 47907 (United States); Tombesi, Francesco [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Cara, Mihai [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Marshall, Herman L. [Kavli Institute for Astrophysics and Space Research, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Kazanas, Demos [NASA’s Goddard Space Flight Center, Astrophysics Science Division, Code 663, Greenbelt, MD 20771 (United States)

    2016-08-01

    Relativistic jets are the most energetic manifestation of the active galactic nucleus (AGN) phenomenon. AGN jets are observed from the radio through gamma-rays and carry copious amounts of matter and energy from the sub-parsec central regions out to the kiloparsec and often megaparsec scale galaxy and cluster environs. While most spatially resolved jets are seen in the radio, an increasing number have been discovered to emit in the optical/near-IR and/or X-ray bands. Here we discuss a spectacular example of this class, the 3C 111 jet, housed in one of the nearest, double-lobed FR II radio galaxies known. We discuss new, deep Chandra and Hubble Space Telescope ( HST ) observations that reveal both near-IR and X-ray emission from several components of the 3C 111 jet, as well as both the northern and southern hotspots. Important differences are seen between the morphologies in the radio, X-ray, and near-IR bands. The long (over 100 kpc on each side), straight nature of this jet makes it an excellent prototype for future, deep observations, as it is one of the longest such features seen in the radio, near-IR/optical, and X-ray bands. Several independent lines of evidence, including the X-ray and broadband spectral shape as well as the implied velocity of the approaching hotspot, lead us to strongly disfavor the EC/CMB model and instead favor a two-component synchrotron model to explain the observed X-ray emission for several jet components. Future observations with NuSTAR , HST , and Chandra will allow us to further constrain the emission mechanisms.

  4. Real-Time Straight-Line Detection for XGA-Size Videos by Hough Transform with Parallelized Voting Procedures.

    Science.gov (United States)

    Guan, Jungang; An, Fengwei; Zhang, Xiangyu; Chen, Lei; Mattausch, Hans Jürgen

    2017-01-30

    The Hough Transform (HT) is a method for extracting straight lines from an edge image. The main limitations of the HT for usage in actual applications are computation time and storage requirements. This paper reports a hardware architecture for HT implementation on a Field Programmable Gate Array (FPGA) with parallelized voting procedure. The 2-dimensional accumulator array, namely the Hough space in parametric form (ρ, θ), for computing the strength of each line by a voting mechanism is mapped on a 1-dimensional array with regular increments of θ. Then, this Hough space is divided into a number of parallel parts. The computation of (ρ, θ) for the edge pixels and the voting procedure for straight-line determination are therefore executable in parallel. In addition, a synchronized initialization for the Hough space further increases the speed of straight-line detection, so that XGA video processing becomes possible. The designed prototype system has been synthesized on a DE4 platform with a Stratix-IV FPGA device. In the application of road-lane detection, the average processing speed of this HT implementation is 5.4ms per XGA-frame at 200 MHz working frequency.

  5. The impact of subsidence on straight and curved modular cementless revision stems in hip revision surgery.

    Science.gov (United States)

    Fraile Suari, A; Gil González, S; Pérez Prieto, D; León García, A; Mestre Cortadellas, C; Tey Pons, M; Marqués López, F

    Subsidence is one of the potential complications in femoral stem revision total hip arthroplasty surgery, and can affect stability and osseointegration. A retrospective study was conducted on the outcomes at one year and 5 years (specifically subsidence and clinical relevance) of 40 consecutive femoral total hip arthroplasty revisions, comparing two modular cementless revision stems, Straight vs. Curved, with 20 patients in each group. No mechanical failure was observed, and there was an improvement in functional outcomes. Mean radiological subsidence was 9.9±4.9mm (straight=10.75mm vs. curved=9.03mm), with no statistically significant difference between groups (p=0,076). Fourteen patients (35%) had ≥10mm of subsidence, up to a maximum of 22mm. The subsidence found in this study is similar to published series, with no short-term clinical manifestations, or an increased number of complications or stem loosening in either the Straight or Curved group. No differences in subsidence were observed at one year and 5 years after surgery between the 2 types of stems. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. The GSA Difference: LGBTQ and Ally Experiences in High Schools with and without Gay-Straight Alliances

    Directory of Open Access Journals (Sweden)

    Tina Fetner

    2015-08-01

    Full Text Available We examine the lived experiences of high-school students who participated in lesbian, gay, bisexual, transgender, and queer (LGBTQ-centered activism of some kind, highlighting the promise of gay-straight alliance groups by comparing the experiences of students at schools with gay-straight alliances (GSA schools with the experiences of students at schools that did not have an LGBTQ-specific group (no-GSA schools. We compare students at GSA and no-GSA schools based on their experiences of harassment, experiences of support from authority figures, and patterns of friendships. We find that students at both types of schools experienced harassment and heard negative comments about lesbian and gay people. However, students at GSA schools reported more support from teachers and administrators than students at no-GSA schools, who have stories of teachers and administrators actively opposing equality for LGBTQ people. Students at GSA schools reported a wide variety of friendships across sexual identities, while students at no-GSA schools felt more isolated and withdrawn. This much-needed qualitative comparative analysis of students’ experiences brings a human face to the improved quality of life that schools with gay-straight alliances can bring to young people.

  7. Design and delivery of the diamond double double bend achromat project

    International Nuclear Information System (INIS)

    Kay, J.; Hammond, N. P.; Thomson, A.

    2016-01-01

    A major project is underway at Diamond Light Source to remove one of the 24 Double Bend Achromat (DBA) Storage Ring cells and replace it with a Double Double Bend Achromat (DDBA). In this way a new Insertion Device (ID) straight can be created and so ID light can be produced and delivered to a beamline previously only capable of receiving Bending Magnet (BM) radiation. This project is in support of the micro-focus Protein Crystallography (MX) beamline VMX-m which is scheduled to take users towards the end of 2017. This paper describes the Engineering Design of the DDBA project in more detail and gives the current status of the project.

  8. Design and delivery of the diamond double double bend achromat project

    Energy Technology Data Exchange (ETDEWEB)

    Kay, J., E-mail: jim.kay@diamond.ac.uk; Hammond, N. P.; Thomson, A. [Diamond Light Source, Didcot, Oxfordshire, UK, OX11 0DE (United Kingdom)

    2016-07-27

    A major project is underway at Diamond Light Source to remove one of the 24 Double Bend Achromat (DBA) Storage Ring cells and replace it with a Double Double Bend Achromat (DDBA). In this way a new Insertion Device (ID) straight can be created and so ID light can be produced and delivered to a beamline previously only capable of receiving Bending Magnet (BM) radiation. This project is in support of the micro-focus Protein Crystallography (MX) beamline VMX-m which is scheduled to take users towards the end of 2017. This paper describes the Engineering Design of the DDBA project in more detail and gives the current status of the project.

  9. A potential flow 2-D vortex panel model: Applications to vertical axis straight blade tidal turbine

    International Nuclear Information System (INIS)

    Wang, L.B.; Zhang, L.; Zeng, N.D.

    2007-01-01

    A potential flow 2-D vortex panel model (VPM2D) for unsteady hydrodynamics calculation of the vertical axis straight blade variable pitch turbine was given for tidal streams energy conversion. Numerical results of predicted instantaneous blade forces and wake flow of the rotor showed good agreement with the test data. The model was also compared with the previous classic free vortex model (V-DART) and vortex method combined with finite element analysis (FEVDTM). It showed that the present model was much better than the former, less complex than the latter and suitable for designing and optimization of the vertical axis straight blade turbine

  10. A comparison of a 'J' wire and a straight wire in successful antegrade cannulation of the superficial femoral artery

    International Nuclear Information System (INIS)

    Gay, D.A.T.; Edwards, A.J.; Puckett, M.A.; Roobottom, C.A.

    2005-01-01

    AIMS: To evaluate the success of two different types of wire in common use in their ability to successfully cannulate the superficial femoral artery (SFA) using antegrade puncture. METHODS: 50 consecutive patients in whom antegrade infra-inguinal intervention was planned, underwent common femoral arterial puncture and then cannulation with either a standard 3 mm 'J' wire or a floppy tipped straight wire (William Cook--Europe). The frequency with which each type of wire entered the SFA or profunda femoris artery without image guidance was recorded. Further analysis was also made of the success of manipulation of the wire into the SFA following profunda cannulation and the use of alternative guide wires. RESULTS: In 19 out of 25 (76%) patients the 'J' wire correctly entered the SFA without image guidance. Only 5 out of 25 (25%) of straight wires entered the SFA with the initial pass (p<0.0001). Following further manipulation with the same wire all except 1 'J' wire was successfully negotiated into the SFA. The same was true for only 9 of the remaining straight wires with 11 patients requiring an alternative guide wire. CONCLUSIONS: When performing antegrade cannulation of the SFA a 'J' wire is more likely to be successful than a straight guide wire

  11. Determining shapes and dimensions of dental arches for the use of straight-wire arches in lingual technique.

    Science.gov (United States)

    Kairalla, Silvana Allegrini; Scuzzo, Giuseppe; Triviño, Tarcila; Velasco, Leandro; Lombardo, Luca; Paranhos, Luiz Renato

    2014-01-01

    This study aims to determine the shape and dimension of dental arches from a lingual perspective, and determine shape and size of a straight archwire used for lingual Orthodontics. The study sample comprised 70 Caucasian Brazilian individuals with normal occlusion and at least four of Andrew's six keys. Maxillary and mandibular dental casts were digitized (3D) and the images were analyzed by Delcam Power SHAPET 2010 software. Landmarks on the lingual surface of teeth were selected and 14 measurements were calculated to determine the shape and size of dental arches. Shapiro-Wilk test determined small arch shape by means of 25th percentile (P25%)--an average percentile for the medium arch; and a large one determined by means of 75th percentile (P75%). T-test revealed differences between males and females in the size of 12 dental arches. The straight-wire arch shape used in the lingual straight wire technique is a parabolic-shaped arch, slightly flattened on its anterior portion. Due to similarity among dental arch sizes shown by males and females, a more simplified diagram chart was designed.

  12. Novel X-ray telescopes for wide-field X-ray monitoring

    International Nuclear Information System (INIS)

    Hudec, R.; Inneman, A.; Pina, L.; Sveda, L.

    2005-01-01

    We report on fully innovative very wide-field of view X-ray telescopes with high sensitivity as well as large field of view. The prototypes are very promising, allowing the proposals for space projects with very wide-field Lobster-eye X-ray optics to be considered. The novel telescopes will monitor the sky with unprecedented sensitivity and angular resolution of order of 1 arcmin. They are expected to contribute essentially to study and to understand various astrophysical objects such as AGN, SNe, Gamma-ray bursts (GRBs), X-ray flashes (XRFs), galactic binary sources, stars, CVs, X-ray novae, various transient sources, etc. The Lobster optics based X-ray All Sky Monitor is capable to detect around 20 GRBs and 8 XRFs yearly and this will surely significantly contribute to the related science

  13. Straight-line assimilation in home-leaving? A comparison of Turks, Somalis and Danes

    DEFF Research Database (Denmark)

    Nielsen, Rikke Skovgaard

    2016-01-01

    The purpose of this paper is to test the evidence for spatial assimilation and straight-line assimilation in the transition of leaving home in Denmark. Based on data from the extensive Danish registers, the paper analyses the home-leaving patterns of Danes, Turkish immigrants, Turkish descendants...

  14. Hard X-ray synchrotron light source for industrial and materials research applications

    International Nuclear Information System (INIS)

    Lehr, H.; Ehrfeld, W.; Moser, H.O.; Schmidt, M.; Herminghaus, H.

    1992-01-01

    The requirements for industrial production or for an industry-related analytical environment is demonstrated for the case of the proposed hard X-ray synchrotron light source. The source is intended to provide radiation mainly for deep X-ray lithography as part of the LIGA-process in microfabrication, and for analytical and diagnostic purposes in materials research and microtechnology. It offers up to 48 bending magnet beamlines with a characteristic wavelength of 2 A. An electron energy of 2.5 GeV and normal conducting magnets will be used. A FODO lattice with a beam emittance of 3x10 -7 m rad and four dispersion-free straight sections to accommodate insertion devices, injection elements and RF structures has been designed. (R.P.) 5 refs.; 4 figs.; 1 tab

  15. Greater Engagement among Members of Gay-Straight Alliances: Individual and Structural Contributors

    Science.gov (United States)

    Poteat, V. Paul; Heck, Nicholas C.; Yoshikawa, Hirokazu; Calzo, Jerel P.

    2016-01-01

    Using youth program models to frame the study of Gay-Straight Alliances (GSAs), we identified individual and structural predictors of greater engagement in these settings with a cross-sectional sample of 295 youth in 33 GSAs from the 2014 Massachusetts GSA Network Survey (69% LGBQ, 68% cisgender female, 68% White, M[subscript age] =16.07).…

  16. Effect of Ankle Positioning During Hamstring Stretches for Improving Straight Leg Hip Flexion Motion.

    Science.gov (United States)

    Laudner, Kevin G; Benjamin, Peter J; Selkow, Noelle M

    2016-03-01

    To compare the effects of stretching the hamstrings with the ankle in either a plantar-flexed (PF) or dorsiflexed (DF) position for improving straight leg hip flexion range of motion (ROM) over a 4-week period. Randomized, single-blinded, pretest, posttest design. Athletic training facility. Each limb of 34 asymptomatic individuals (15 males, 19 females) was randomly assigned to one of the 3 groups. Twenty-four limbs received hamstring stretches with the ankle in DF, 24 limbs received hamstring stretches with the ankle in PF, and 20 limbs received no stretch (control). Ankle position (PF, DF) during hamstring stretching. We measured pretest and posttest passive straight leg hip flexion ROM with the test ankle in a neutral position. For the intervention groups, the test limb was passively stretched with the ankle held in end range DF or PF for their respective group. Each stretch was held for 30 seconds for a total of 3 applications. Two treatment sessions were completed per week for a total of 4 weeks. The control limbs received no stretching during the 4-week period. We conducted 1-way analyses of covariance to determine significant changes in ROM between groups (P hamstrings in either PF or DF improve straight leg hip ROM compared with a control group. The results of this study should be considered by clinicians when determining the optimal stretching techniques aimed at increasing hamstring length.

  17. Technical exercises for the execution of straight punches in boxers of the child category

    Directory of Open Access Journals (Sweden)

    Giraldo Machuat Santana

    2017-12-01

    Full Text Available The present research aims to put into the hands of the coaches a material whose value in the methodological didactic can serve as a tool in the search for alternative solutions to the problems that today affect the technical and tactical preparation of our boxers from the point of view an offensive view, specifically on the effectiveness of straight blows to the face and trunk. For the accomplishment of this work a sample of 12 athletes was chosen, all belonging to the category 11-12 years of the municipality San Juan y Martínez to which as an experimental form ,the introduction of a methodology supported in a set of exercises was applied, as part of the teaching-learning process of athletes, regarding the execution of straight blows to the face and trunk, as an essential tactical offensive technical aspect in this age category to achieve victory in combat. A total of 16 observations were made to trainings and competitions to appreciate how the technique behaved in the execution of these blows by the athletes research subject. As a result there is a proposal of exercises that through a correct execution and implementation can contribute to the improvement of the effectiveness in the execution of the straight blows to the face and trunk of the boxers of the category 11 and 12 years of the combined sport nº 1 of the municipality San Juan y Martínez.

  18. CeB6 electron gun for the soft X-ray FEL project at SPring-8

    International Nuclear Information System (INIS)

    Togawa, K.; Baba, H.; Onoe, K.; Inagaki, T.; Shintake, T.; Matsumoto, H.

    2004-01-01

    A pulsed high-voltage electron gun with a thermionic cathode is under development for the injector system of the soft X-ray FEL project at SPring-8 (SCSS project). A CeB 6 single crystal of 3 mm diameter was chosen as a thermionic cathode because of its excellent emission properties, i.e., high resistance against contamination, uniform emission density and smooth surface. The CeB 6 cathode can produce a 3 A beam with 2 μs FWHM. A gun voltage of -500 kV was chosen as a compromise between the need for controlling emittance growth and minimizing the risks of high-voltage arcing. We have constructed a 500 kV electron gun test stand and have begun performance tests. This paper describes the basic design and the current status of the hardware R and D on the CeB 6 gun

  19. The Teams from Building 904 celebrated the assembly of the 100th short straight section on 11 April

    CERN Multimedia

    Patrice Loiez

    2005-01-01

    The 100th short straight section for the Large Hadron Collider was assembled at CERN at the beginning of April. These units combine superconducting quadrupoles and other multipole corrector magnets, housed in their cryostats, which are used to guide, focus and fine-tune the beam in the LHC. Building 904, where the 474 short straight sections are being assembled, is often called "Lego Land" by the workers, with a touch of humor and pride because of the wide variety of these sets of magnets and cryostats

  20. AXAOTHER XL -- A spreadsheet for determining doses for incidents caused by tornadoes or high-velocity straight winds

    International Nuclear Information System (INIS)

    Simpkins, A.A.

    1996-09-01

    AXAOTHER XL is an Excel Spreadsheet used to determine dose to the maximally exposed offsite individual during high-velocity straight winds or tornado conditions. Both individual and population doses may be considered. Potential exposure pathways are inhalation and plume shine. For high-velocity straight winds the spreadsheet has the capability to determine the downwind relative air concentration, however for the tornado conditions, the user must enter the relative air concentration. Theoretical models are discussed and hand calculations are performed to ensure proper application of methodologies. A section has also been included that contains user instructions for the spreadsheet

  1. Three-dimensional reconstruction of neutron, gamma-ray, and x-ray sources using spherical harmonic decomposition

    Science.gov (United States)

    Volegov, P. L.; Danly, C. R.; Fittinghoff, D.; Geppert-Kleinrath, V.; Grim, G.; Merrill, F. E.; Wilde, C. H.

    2017-11-01

    Neutron, gamma-ray, and x-ray imaging are important diagnostic tools at the National Ignition Facility (NIF) for measuring the two-dimensional (2D) size and shape of the neutron producing region, for probing the remaining ablator and measuring the extent of the DT plasmas during the stagnation phase of Inertial Confinement Fusion implosions. Due to the difficulty and expense of building these imagers, at most only a few two-dimensional projections images will be available to reconstruct the three-dimensional (3D) sources. In this paper, we present a technique that has been developed for the 3D reconstruction of neutron, gamma-ray, and x-ray sources from a minimal number of 2D projections using spherical harmonics decomposition. We present the detailed algorithms used for this characterization and the results of reconstructed sources from experimental neutron and x-ray data collected at OMEGA and NIF.

  2. Pre-School Students' Informal Acquisitions Regarding the Concepts of Point and Straight Line

    Science.gov (United States)

    Orbay, Keziban; Develi, Mehmet Hikmet

    2015-01-01

    This study aimed to investigate the informal cognitive structures regarding "point" and "straight line"--two basic and undefined terms of geometry--in children registered in preschool--the previous step before in-class formal education process. The study was conducted with the participation of 50 children enrolled in nursery,…

  3. Understanding the Active Straight Leg Raise (ASLR): An electromyographic study in healthy subjects

    NARCIS (Netherlands)

    Hu, H.; Meijer, O.G.; Bruijn, S.M.; Strijers, R.L.M.; Nanayakkara, P.W.B.; van Royen, B.J.; Wu, W; Xia, C.; van Dieen, J.H.

    2012-01-01

    The Active Straight Leg Raise (ASLR) is an important test in diagnosing pelvic girdle pain (PGP). It is difficult to understand what happens normally during the ASLR, let alone why it would be impaired in PGP. In the present study, healthy subjects performed the ASLR under normal conditions, with

  4. Design and Validation of a Straight-Copy Typewriting Prognostic Test Using Kinesthetic Sensitivity.

    Science.gov (United States)

    Olson, Norma Jean

    1979-01-01

    Describes the development and application of a kinesthetic sensitivity test to determine whether it is a valid and reliable measure of straight-copy typing speed and accuracy. The author states that this kinesthetic sensitivity instrument may be used as a prognostic aptitude test and recommends administration methods. (MF)

  5. Gamma-ray streaming in bent ducts and voids

    International Nuclear Information System (INIS)

    Bourdet, L.; Nimal, J.C.; Vergnaud, T.

    1983-05-01

    We have developed an analytical method to calculate gamma-ray streaming through straight ducts and a numerical method to study the gamma propagation in bends or in annular clearances. The whole set allows a rigorous treatment of gamma streaming through bent ducts. In the same time a Monte Carlo method allows to study any form of geometry, by using sophisticated biasing techniques. All these developments are made with a simplified albedo. An easy to use code is also proposed to calculate very general albedos and a code to calculate the dose rate due to reflection in a room. Gamma dose rate albedos are determined for all elements and the energy range which concerns fission reactors

  6. Empirical model for the Earth's cosmic ray shadow at 400 KM: prohibited cosmic ray access

    International Nuclear Information System (INIS)

    Humble, J.E.; Smart, D.F.; Shea, M.A.

    1985-01-01

    The possibility of constructing a unit sphere of access that describes the cosmic radiation allowed to an Earth-orbiting spacecraft is discussed. It is found that it is possible to model the occluded portion of the cosmic ray sphere of access as a circular projection with a diameter bounded by the satellite-Earth horizon. Maintaining tangency at the eastern edge of the spacecraft-Earth horizon, this optically occluded area is projected downward by an angle beta which is a function of the magnetic field inclination and cosmic ray arrival direction. This projected plane, corresponding to the forbidden area of cosmic ray access, is bounded by the spacecraft-Earth horizon in easterly directions, and is rotated around the vertical axis by an angle alpha from the eastern direction, where the angle alpha is a function of the offset dipole latitude of the spacecraft

  7. An Examination of Muscle Activation and Power Characteristics While Performing the Deadlift Exercise With Straight and Hexagonal Barbells.

    Science.gov (United States)

    Camara, Kevin D; Coburn, Jared W; Dunnick, Dustin D; Brown, Lee E; Galpin, Andrew J; Costa, Pablo B

    2016-05-01

    The deadlift exercise is commonly performed to develop strength and power, and to train the lower-body and erector spinae muscle groups. However, little is known about the acute training effects of a hexagonal barbell vs. a straight barbell when performing deadlifts. Therefore, the purpose of this study was to examine the hexagonal barbell in comparison with the straight barbell by analyzing electromyography (EMG) from the vastus lateralis, biceps femoris, and erector spinae, as well as peak force, peak power, and peak velocity using a force plate. Twenty men with deadlifting experience volunteered to participate in the study. All participants completed a 1 repetition maximum (1RM) test with each barbell on 2 separate occasions. Three repetitions at 65 and 85% 1RM were performed with each barbell on a third visit. The results revealed that there was no significant difference for 1RM values between the straight and hexagonal barbells (mean ± SD in kg = 181.4 ± 27.3 vs. 181.1 ± 27.6, respectively) (p > 0.05). Significantly greater normalized EMG values were found from the vastus lateralis for both the concentric (1.199 ± 0.22) and eccentric (0.879 ± 0.31) phases of the hexagonal-barbell deadlift than those of the straight-barbell deadlift (0.968 ± 0.22 and 0.559 ± 1.26), whereas the straight-barbell deadlift led to significantly greater EMG values from the bicep femoris during the concentric phase (0.835 ± 0.19) and the erector spinae (0.753 ± 0.28) during the eccentric phase than the corresponding values for the hexagonal-barbell deadlift (0.723 ± 0.20 and 0.614 ± 0.21) (p ≤ 0.05). In addition, the hexagonal-barbell deadlift demonstrated significantly greater peak force (2,553.20 ± 371.52 N), peak power (1,871.15 ± 451.61 W), and peak velocity (0.805 ± 0.165) values than those of the straight-barbell deadlift (2,509.90 ± 364.95 N, 1,639.70 ± 361.94 W, and 0.725 ± 0.138 m·s, respectively) (p ≤ 0.05). These results suggest that the barbells led

  8. Numerical evaluation of methods for computing tomographic projections

    International Nuclear Information System (INIS)

    Zhuang, W.; Gopal, S.S.; Hebert, T.J.

    1994-01-01

    Methods for computing forward/back projections of 2-D images can be viewed as numerical integration techniques. The accuracy of any ray-driven projection method can be improved by increasing the number of ray-paths that are traced per projection bin. The accuracy of pixel-driven projection methods can be increased by dividing each pixel into a number of smaller sub-pixels and projecting each sub-pixel. The authors compared four competing methods of computing forward/back projections: bilinear interpolation, ray-tracing, pixel-driven projection based upon sub-pixels, and pixel-driven projection based upon circular, rather than square, pixels. This latter method is equivalent to a fast, bi-nonlinear interpolation. These methods and the choice of the number of ray-paths per projection bin or the number of sub-pixels per pixel present a trade-off between computational speed and accuracy. To solve the problem of assessing backprojection accuracy, the analytical inverse Fourier transform of the ramp filtered forward projection of the Shepp and Logan head phantom is derived

  9. Soft x-ray Planetary Imager

    Data.gov (United States)

    National Aeronautics and Space Administration — The project is to prototype a soft X-ray Imager for planetary applications that has the sensitivity to observe solar system sources of soft  X-ray emission. A strong...

  10. Eigenvector decomposition of full-spectrum x-ray computed tomography.

    Science.gov (United States)

    Gonzales, Brian J; Lalush, David S

    2012-03-07

    Energy-discriminated x-ray computed tomography (CT) data were projected onto a set of basis functions to suppress the noise in filtered back-projection (FBP) reconstructions. The x-ray CT data were acquired using a novel x-ray system which incorporated a single-pixel photon-counting x-ray detector to measure the x-ray spectrum for each projection ray. A matrix of the spectral response of different materials was decomposed using eigenvalue decomposition to form the basis functions. Projection of FBP onto basis functions created a de facto image segmentation of multiple contrast agents. Final reconstructions showed significant noise suppression while preserving important energy-axis data. The noise suppression was demonstrated by a marked improvement in the signal-to-noise ratio (SNR) along the energy axis for multiple regions of interest in the reconstructed images. Basis functions used on a more coarsely sampled energy axis still showed an improved SNR. We conclude that the noise-resolution trade off along the energy axis was significantly improved using the eigenvalue decomposition basis functions.

  11. Life cycle assessment of village electrification based on straight jatropha oil in Chhattisgarh, India

    Energy Technology Data Exchange (ETDEWEB)

    Gmuender, Simon Michael; Zah, Rainer; Widmer, Rolf [Technology and Society Lab, Swiss Federal Laboratories for Materials Testing and Research (EMPA), Ueberlandstr. 129, 8600 Duebendorf (Switzerland); Bhatacharjee, Somnath [Winrock India International, New Delhi (India); Classen, Mischa [First Climate AG, Zuerich (Switzerland); Mukherjee, Prodyut [Sir Dorabji Tata Trust and Allied Trusts, New Delhi (India)

    2010-03-15

    A decentralized power generation plant fuelled by straight jatropha oil was implemented in 2006 in Ranidhera, Chhattisgarh, India. The goal of this study was to assess the environmental sustainability of that electrification project in order to provide a scientific basis for policy decisions on electrifying remote villages. A full Life Cycle Assessment (LCA) was conducted on jatropha-based rural electrification and then compared with other electrification approaches such as photovoltaic (PV), grid connection and a diesel-fuelled power generator. In summary, the jatropha-based electrification in Ranidhera reduces greenhouse gas emissions over the full life cycle by a factor of 7 compared to a diesel generator or grid connection. The environmental performance is only slightly improved, mainly due to the high air pollution from pre-heating the jatropha seeds. With additional measures oil extraction and overall efficiency could be further improved. However, environmental benefits can only be achieved if jatropha is cultivated on marginal land and land use competition can be excluded. Under these conditions, jatropha-based electricity generation might be a useful alternative to other renewable electrification options, as the technology is very sturdy and can be maintained even in remote and highly under-developed regions. (author)

  12. High resolution projection X-ray microscope equipped with fluorescent X-ray analyzer and its applications

    International Nuclear Information System (INIS)

    Minami, K; Saito, Y; Kai, H; Shirota, K; Yada, K

    2009-01-01

    We have newly developed an open type fine-focus X-ray tube 'TX-510' to realize a spatial resolution of 50nm and to radiate low energy characteristic X-rays for giving high absorption contrast to images of microscopic organisms. The 'TX-510' employs a ZrO/W(100) Schottky emitter and an 'In-Lens Field Emission Gun'. The key points of the improvements are (1) reduced spherical aberration coefficient of magnetic objective lens, (2) easy and accurate focusing, (3) newly designed astigmatism compensator, (4) segmented thin film target for interchanging the target materials by electron beam shift and (5) fluorescent X-ray analysis system.

  13. Attenuation correction of myocardial SPECT images with X-ray CT. Effects of registration errors between X-ray CT and SPECT

    International Nuclear Information System (INIS)

    Takahashi, Yasuyuki; Murase, Kenya; Mochizuki, Teruhito; Motomura, Nobutoku

    2002-01-01

    Attenuation correction with an X-ray CT image is a new method to correct attenuation on SPECT imaging, but the effect of the registration errors between CT and SPECT images is unclear. In this study, we investigated the effects of the registration errors on myocardial SPECT, analyzing data from a phantom and a human volunteer. Registerion (fusion) of the X-ray CT and SPECT images was done with standard packaged software in three dimensional fashion, by using linked transaxial, coronal and sagittal images. In the phantom study, and X-ray CT image was shifted 1 to 3 pixels on the x, y and z axes, and rotated 6 degrees clockwise. Attenuation correction maps generated from each misaligned X-ray CT image were used to reconstruct misaligned SPECT images of the phantom filled with 201 Tl. In a human volunteer, X-ray CT was acquired in different conditions (during inspiration vs. expiration). CT values were transferred to an attenuation constant by using straight lines; an attenuation constant of 0/cm in the air (CT value=-1,000 HU) and that of 0.150/cm in water (CT value=0 HU). For comparison, attenuation correction with transmission CT (TCT) data and an external γ-ray source ( 99m Tc) was also applied to reconstruct SPECT images. Simulated breast attenuation with a breast attachment, and inferior wall attenuation were properly corrected by means of the attenuation correction map generated from X-ray CT. As pixel shift increased, deviation of the SPECT images increased in misaligned images in the phantom study. In the human study, SPECT images were affected by the scan conditions of the X-ray CT. Attenuation correction of myocardial SPECT with an X-ray CT image is a simple and potentially beneficial method for clinical use, but accurate registration of the X-ray CT to SPECT image is essential for satisfactory attenuation correction. (author)

  14. Straight-run vs. sex separate rearing for two broiler genetic lines Part 2: Economic analysis and processing advantages.

    Science.gov (United States)

    Da Costa, M J; Colson, G; Frost, T J; Halley, J; Pesti, G M

    2017-07-01

    The objective of this analysis was to evaluate the effects of raising broilers under sex separate and straight-run conditions for 2 broiler genetic lines. One-day-old Ross 308 and Ross 708 chicks (n = 1,344) were sex separated and placed in 48 pens according to rearing type: sex separate (28 males or 28 females) or straight-run (14 males + 14 females). There were 3 dietary phases: starter (zero to 17 d), grower (17 to 32 d), and finisher (32 to 48 d). Bird individual BW and group feed intakes were measured at 12, 17, 25, 32, 42, and 48 d to evaluate performance. At 33, 43, and 49 d 4 birds per pen (straight-run pens 2 males + 2 females) were sampled for carcass yield evaluation. Data were analyzed using linear and non-linear regression in order to estimate feed intake and cut-up weights at 3 separate market weights (1,700, 2,700, and 3,700 g). Returns over feed cost were estimated for a 1.8 million broiler complex for each rearing system and under 9 feed/meat price scenarios. Overall, rearing birds that were sex separated resulted in extra income that ranged from ${\\$}$48,824 to ${\\$}$330,300 per week, depending on the market targeted and feed and meat price scenarios. Sex separation was shown to be especially important in disadvantageous scenarios in which feed prices were high. Gains from sex separation were markedly higher for the Ross 708 than for the Ross 308 broilers. Bird variability also was evaluated at the 3 separate market ages under narrow ranges of BW that were targeted. Straight-run birds decreased the number of birds present in the desired range. Depending on market weight, straight-run rearing resulted in 9.1 to 16.6% fewer birds than sex separate rearing to meet marketing goals. It was concluded that sex separation can result in increased company profitability and have possible beneficial effects at the processing plant due to increased bird uniformity. © 2017 Poultry Science Association Inc.

  15. Insertion forces and intracochlear trauma in temporal bone specimens implanted with a straight atraumatic electrode array.

    Science.gov (United States)

    Mirsalehi, Marjan; Rau, Thomas S; Harbach, Lenka; Hügl, Silke; Mohebbi, Saleh; Lenarz, Thomas; Majdani, Omid

    2017-05-01

    The aim of the study was to evaluate insertion forces during manual insertion of a straight atraumatic electrode in human temporal bones, and post-implantation histologic evaluation of the samples to determine whether violation of intracochlear structures is related to insertion forces. In order to minimize intracochlear trauma and preserve residual hearing during cochlear implantation, knowledge of the insertion forces is necessary. Ten fresh frozen human temporal bones were prepared with canal wall down mastoidectomy. All samples were mounted on a one-axis force sensor. Insertion of a 16-mm straight atraumatic electrode was performed from different angles to induce "traumatic" insertion. Histologic evaluation was performed in order to evaluate intracochlear trauma. In 4 of 10 samples, dislocation of the electrode into scala vestibuli was observed. The mean insertion force for all 10 procedures was 0.003 ± 0.005 N. Insertion forces measured around the site of dislocation to scala vestibuli in 3 of 4 samples were significantly higher than insertion forces at the same location of the cochleae measured in samples without trauma (p straight atraumatic electrode is lower than reported by other studies using longer electrodes. Based on our study, insertion forces leading to basilar membrane trauma may be lower than the previously reported direct rupture forces.

  16. Smoothed Particle Inference: A Kilo-Parametric Method for X-ray Galaxy Cluster Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, John R.; Marshall, P.J.; /KIPAC, Menlo Park; Andersson, K.; /Stockholm U. /SLAC

    2005-08-05

    We propose an ambitious new method that models the intracluster medium in clusters of galaxies as a set of X-ray emitting smoothed particles of plasma. Each smoothed particle is described by a handful of parameters including temperature, location, size, and elemental abundances. Hundreds to thousands of these particles are used to construct a model cluster of galaxies, with the appropriate complexity estimated from the data quality. This model is then compared iteratively with X-ray data in the form of adaptively binned photon lists via a two-sample likelihood statistic and iterated via Markov Chain Monte Carlo. The complex cluster model is propagated through the X-ray instrument response using direct sampling Monte Carlo methods. Using this approach the method can reproduce many of the features observed in the X-ray emission in a less assumption-dependent way that traditional analyses, and it allows for a more detailed characterization of the density, temperature, and metal abundance structure of clusters. Multi-instrument X-ray analyses and simultaneous X-ray, Sunyaev-Zeldovich (SZ), and lensing analyses are a straight-forward extension of this methodology. Significant challenges still exist in understanding the degeneracy in these models and the statistical noise induced by the complexity of the models.

  17. OMEGA project

    International Nuclear Information System (INIS)

    Shibuya, E.H.

    1989-01-01

    The OMEGA - Observation of Multiple particle production, Exotic Interactions and Gamma-ray Air Shower-project is presented. The project try to associate photosensitive detectors from experiences of hadronic interactions with electronic detectors used by experiences that investigate extensive atmospheric showers. (M.C.K.)

  18. Improving limited-projection-angle fluorescence molecular tomography using a co-registered x-ray computed tomography scan.

    Science.gov (United States)

    Radrich, Karin; Ale, Angelique; Ermolayev, Vladimir; Ntziachristos, Vasilis

    2012-12-01

    We examine the improvement in imaging performance, such as axial resolution and signal localization, when employing limited-projection-angle fluorescence molecular tomography (FMT) together with x-ray computed tomography (XCT) measurements versus stand-alone FMT. For this purpose, we employed living mice, bearing a spontaneous lung tumor model, and imaged them with FMT and XCT under identical geometrical conditions using fluorescent probes for cancer targeting. The XCT data was employed, herein, as structural prior information to guide the FMT reconstruction. Gold standard images were provided by fluorescence images of mouse cryoslices, providing the ground truth in fluorescence bio-distribution. Upon comparison of FMT images versus images reconstructed using hybrid FMT and XCT data, we demonstrate marked improvements in image accuracy. This work relates to currently disseminated FMT systems, using limited projection scans, and can be employed to enhance their performance.

  19. A Comparison of pical Root Resorption in Incisors after Fixed Orthodontic Treatment with Standard Edgewise and Straight Wire (MBT) Method.

    Science.gov (United States)

    Zahed Zahedani, Sm; Oshagh, M; Momeni Danaei, Sh; Roeinpeikar, Smm

    2013-09-01

    One of the major outcomes of orthodontic treatment is the apical root resorption of teeth moved during the treatment. Identifying the possible risk factors, are necessary for every orthodontist. The aim of this study was to compare the rate of apical root resorption after fixed orthodontic treatment with standard edgewise and straight wire (MBT) method, and also to evaluate other factors effecting the rate of root resorption in orthodontic treatments. In this study, parallel periapical radiographs of 127 patients imaging a total of 737 individual teeth, were collected. A total of 76 patients were treated by standard edgewise and 51 patients by straight wire method. The periapical radiographs were scanned and then the percentage of root resorption was calculated by Photoshop software. The data were analyzed by Paired-Samples t-test and the Generalized Linear Model adopting the SPSS 15.0. In patients treated with straight wire method (MBT), mean root resorption was 18.26% compared to 14.82% in patients treated with standard edgewise technique (proot resorption,statistically significant (proot resorption in this study. Having more root resorption in the straight wire method and less in the standard edgewise technique can be attributed to more root movement in pre-adjusted MBT technique due to the brackets employed in this method.

  20. Assessment of corneal astigmatism following frown and straight incision forms in sutureless manual small incision cataract surgery

    Directory of Open Access Journals (Sweden)

    Amedo AO

    2016-04-01

    Full Text Available Angela Ofeibea Amedo, Kwadwo Amoah, Nana Yaa Koomson, David Ben Kumah, Eugene Appenteng Osae Department of Optometry and Visual Science, Kwame Nkrumah University of Science and Technology, Kumasi, Ghana Abstract: To investigate which of two tunnel incision forms (frown versus straight in sutureless manual small incision cataract surgery creates more corneal astigmatism. Sixty eyes of 60 patients who had consented to undergo cataract surgery and to partake in this study were followed from baseline through >12-week postoperative period. Values of preoperative and postoperative corneal astigmatism for the 60 eyes, measured with a Bausch and Lomb keratometer, were extracted from the patients’ cataract surgery records. Residual astigmatism was computed as the difference between preoperative and postoperative keratometry readings. Visual acuity was assessed during the preoperative period and at each postoperative visit with a Snellen chart at 6 m. Fifty eyes of 50 patients were successfully followed-up on. Overall, the mean residual astigmatism was 0.75±0.12 diopters. The differences in mean residual astigmatism between the two different incision groups were statistically significant (t [48]=6.33, P<0.05; frown incision group recorded 1.00±0.12 diopters, whereas the straight incision group recorded 0.50±0.12 diopters. No significant difference was observed between male and female groups (t [48]=0.24, P>0.05. Residual corneal astigmatism in the frown incision group was significantly higher than in the straight incision group. Fisher’s exact test did not reveal a significant association between incision forms and visual acuity during the entire postoperative period (P>0.05. Keywords: cataract, residual corneal astigmatism, frown incision, straight incision

  1. Determining shapes and dimensions of dental arches for the use of straight-wire arches in lingual technique

    Directory of Open Access Journals (Sweden)

    Silvana Allegrini Kairalla

    2014-10-01

    Full Text Available INTRODUCTION: This study aims to determine the shape and dimension of dental arches from a lingual perspective, and determine shape and size of a straight archwire used for lingual Orthodontics. METHODS: The study sample comprised 70 Caucasian Brazilian individuals with normal occlusion and at least four of Andrew's six keys. Maxillary and mandibular dental casts were digitized (3D and the images were analyzed by Delcam Power SHAPET 2010 software. Landmarks on the lingual surface of teeth were selected and 14 measurements were calculated to determine the shape and size of dental arches. RESULTS: Shapiro-Wilk test determined small arch shape by means of 25th percentile (P25% - an average percentile for the medium arch; and a large one determined by means of 75th percentile (P75%. T-test revealed differences between males and females in the size of 12 dental arches. CONCLUSION: The straight-wire arch shape used in the lingual straight wire technique is a parabolic-shaped arch, slightly flattened on its anterior portion. Due to similarity among dental arch sizes shown by males and females, a more simplified diagram chart was designed.

  2. The promotion of unhealthy habits in gay, lesbian, and straight intimate partnerships.

    Science.gov (United States)

    Reczek, Corinne

    2012-09-01

    Health habits are linked to nearly half of U.S. and British deaths annually. While a legacy of research suggests that marriage has important positive consequences for health habits, recent work emphasizes that intimate ties can also deter from healthy habits and promote unhealthy habits. However, few studies examine the mechanisms through which unhealthy habits are promoted in marriage. Moreover, little research explores how unhealthy habits are promoted in intimate ties other than marriage-such as in gay and lesbian cohabiting relationships. The present study analyzes the mechanisms through which gay, lesbian, and straight long-term partners (N = 120) contribute to one another's unhealthy habits. Three distinct mechanisms emerge. First, respondents identify a process of unilateral health habit diffusion wherein one partner's health habits directly influence the other partners' habits. Second, respondents describe bilateral unhealthy habit diffusion, wherein both partner's unhealthy habits are reinforced via mutual pleasure seeking or mutual failed motivation. Third, respondents describe a discourse of personal responsibility, wherein both partners purposefully fail to deter one another's unhealthy habits. Analysis further illustrates how these mechanisms operate differently for men and women in gay, lesbian, and straight relationships. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Application of failure assessment diagram methods to cracked straight pipes and elbows

    International Nuclear Information System (INIS)

    Ainsworth, R.A.; Gintalas, M.; Sahu, M.K.; Chattopadhyay, J.; Dutta, B.K.

    2016-01-01

    This paper reports fracture assessments of large-scale straight pipes and elbows of various pipe diameters and crack sizes. The assessments estimate the load for ductile fracture initiation using the failure assessment diagram method. Recent solutions in the literature for stress intensity factor and limit load provide the analysis inputs. An assessment of constraint effects is also performed using recent solutions for elastic T-stress. It is found that predictions of initiation load are close to the experimental values for straight pipes under pure bending. For elbows, there is generally increased conservatism in the sense that the experimental loads are greater than those predicted. The effects of constraint are found not to be a major contributor to the initiation fracture assessments but may have some influence on the ductile crack extension. - Highlights: • This paper presents assessments of the loads for ductile fracture initiation in 21 large-scale piping tests. • Modern stress intensity factor and limit load solutions were used for standard failure assessment diagram methods. • This leads to generally accurate assessments of the loads for ductile crack initiation. • The effects of constraint are found not to be a major contributor to the initiation fracture assessments.

  4. Limited effect of dopaminergic medication on straight walking and turning in early to moderate Parkinson’s disease during single and dual tasking

    Directory of Open Access Journals (Sweden)

    Morad eElshehabi

    2016-01-01

    Full Text Available Background: In Parkinson’s disease (PD, the effects of dopaminergic medication on straight walking and turning were mainly investigated under single tasking (ST conditions. However, multitasking situations are considered more daily relevant.Methods: Thirty-nine early to moderate PD patients performed the following standarized ST and dual tasks (DT as fast as possible for one minute during On- and Off-medication while wearing inertial sensors: straight walking and turning, checking boxes, and subtracting serial 7s. Quantitative gait parameters, as well as velocity of the secondary tasks were analyzed.Results: The following parameters improved significantly in On-medication during ST: gait velocity during straight walking (p=0.03; step duration (p=0.048 and peak velocity (p=0.04 during turning; velocity of checking boxes during ST (p=0.04 and DT (p=0.04. Velocity of checking boxes was the only parameter that also improved during DT.Conclusion: These results suggest that dopaminergic medication does not relevantly influence straight walking and turning in early to moderate PD during DT.

  5. Computerized tomographic x-ray scanner system and gantry assembly

    International Nuclear Information System (INIS)

    Doyd, D.P.; Lanzara, G.

    1991-01-01

    This patent describes a scanner assembly. It comprises: a support head, a C-shaped gantry, means for supporting the gantry in the support head for rotating movement, an x-ray source mounted on one side of the gantry for independent movement with respect to a detector array along the gantry, the x-ray source projecting x-rays across the gantry, and a detector array mounted on the other side of a gantry for independent movement with respect to the x-ray source along the gantry, the detector array serving to receive the projected x-rays

  6. The evaluated gamma-ray activation file (EGAF)

    International Nuclear Information System (INIS)

    Firestone, R.B.; Molnar, G.L.; Revay, Zs.; Belgya, T.; McNabb, D.P.; Sleaford, B.W.

    2004-01-01

    The Evaluated Gamma-ray Activation File (EGAF), a new database of prompt and delayed neutron capture g-ray cross sections, has been prepared as part of an International Atomic Energy Agency (IAEA) Coordinated Research Project to develop a ''Database of Prompt Gamma-rays from Slow Neutron Capture for Elemental Analysis.'' Recent elemental g-ray cross-section measurements performed with the guided neutron beam at the Budapest Reactor have been combined with data from the literature to produce the EGAF database. EGAF contains thermal cross sections for ∼ 35,000 prompt and delayed g-rays from 262 isotopes. New precise total thermal radiative cross sections have been derived for many isotopes from the primary and secondary gamma-ray cross sections and additional level scheme data. An IAEA TECDOC describing the EGAF evaluation and tabulating the most prominent g-rays will be published in 2004. The TECDOC will include a CD-ROM containing the EGAF database in both ENSDF and tabular formats with an interactive viewer for searching and displaying the data. The Isotopes Project, Lawrence Berkeley National Laboratory continues to maintain and update the EGAF file. These data are available on the Internet from both the IAEA and Isotopes Project websites

  7. Kharkov X-ray Generator Based On Compton Scattering

    International Nuclear Information System (INIS)

    Shcherbakov, A.; Zelinsky, A.; Mytsykov, A.; Gladkikh, P.; Karnaukhov, I.; Lapshin, V.; Telegin, Y.; Androsov, V.; Bulyak, E.; Botman, J.I.M.; Tatchyn, R.; Lebedev, A.

    2004-01-01

    Nowadays X-ray sources based on storage rings with low beam energy and Compton scattering of intense laser beams are under development in several laboratories. An international cooperative project of an advanced X-ray source of this type at the Kharkov Institute of Physics and Technology (KIPT) is described. The status of the project is reviewed. The design lattice of the storage ring and calculated X-ray beam parameters are presented. The results of numerical simulation carried out for proposed facility show a peak spectral X-ray intensity of about 1014 can be produced

  8. X-Ray diagnostics and their relation to a successful endodontic treatment

    International Nuclear Information System (INIS)

    Cecetkova, A.; Ondrasovicova, J.

    2008-01-01

    Radiography plays very major rule in endodontic. One of the most used method is intraoral radiography ( intraoral diagnostic x-ray, x-ray with hand root instrument, recall, after call and follow up x-ray ). These radiographic pictures help us detect the morphology of the root canal system, endodontic complications and periapical lessions. X-ray radiographs have to be isometric in the ortoradial projection. Some cases we may use the ex-centric projection (mesial and distal projection). Endodontic complications as broken hand root instrument, via falsa, intra-canal step may be confirmed by intraoral x-ray radiographs. (authors)

  9. The DFBX cryogenic distribution boxes for the LHC straight sections

    International Nuclear Information System (INIS)

    Zbasnik, Jon P.; Corradi, Carol A.; Green, Michael A.; Kajiyama, Y.; Knolls, Michael J.; LaMantia, Roberto F.; Rasson, Joseph E.; Reavill, Dulie; Turner, William C.

    2002-01-01

    The DFBX distribution boxes are designed to connect the LHC cryogenic distribution system to the interaction region quadrupoles [1] and dipoles for the Large Hadron Collider (LHC). The DFBX distribution boxes also have the current leads for the superconducting interaction region magnets and the LHC interaction region correction coils. The DFBX boxes also connect the magnet and cryogenic instrumentation to the CERN data collection system. The DFBX boxes serve as the cryogenic circulation center and the nerve center for four of the LHC straight sections. This report describes primarily the cryogenic function of the DFBXs

  10. Bit-mapped Holograms Using Phase Transition Mastering (PTM) and Blu-ray Disks

    International Nuclear Information System (INIS)

    Barnhart, Donald

    2013-01-01

    Due to recent advances made in data storage, cloud computing, and Blu-ray mastering technology, it is now straight forward to calculate, store, transfer, and print bitmapped holograms that use terabytes of data and tera-pixels of information. This presentation reports on the potential of using the phase transition mastering (PTM) process to construct bitmapped, computer generated holograms with spatial resolutions of 5000 line-pairs/mm (70 nm pixel width). In particular, for Blu-ray disk production, Sony has developed a complete process that could be alternately deployed in holographic applications. The PTM process uses a 405 nm laser to write phase patterns onto a layer of imperfect transition metal oxides that is deposited onto an 8 inch silicon wafer. After the master hologram has been constructed, its imprint can then be cheaply mass produced with the same process as Blu-ray disks or embossed holograms. Unlike traditional binary holograms made with expensive e-beam lithography, the PTM process has the potential for multiple phase levels using inexpensive optics similar to consumer-grade desktop Blu-ray writers. This PTM process could revolutionise holography for entertainment, industrial, and scientific applications.

  11. Bit-mapped Holograms Using Phase Transition Mastering (PTM) and Blu-ray Disks

    Science.gov (United States)

    Barnhart, Donald

    2013-02-01

    Due to recent advances made in data storage, cloud computing, and Blu-ray mastering technology, it is now straight forward to calculate, store, transfer, and print bitmapped holograms that use terabytes of data and tera-pixels of information. This presentation reports on the potential of using the phase transition mastering (PTM) process to construct bitmapped, computer generated holograms with spatial resolutions of 5000 line-pairs/mm (70 nm pixel width). In particular, for Blu-ray disk production, Sony has developed a complete process that could be alternately deployed in holographic applications. The PTM process uses a 405 nm laser to write phase patterns onto a layer of imperfect transition metal oxides that is deposited onto an 8 inch silicon wafer. After the master hologram has been constructed, its imprint can then be cheaply mass produced with the same process as Blu-ray disks or embossed holograms. Unlike traditional binary holograms made with expensive e-beam lithography, the PTM process has the potential for multiple phase levels using inexpensive optics similar to consumer-grade desktop Blu-ray writers. This PTM process could revolutionise holography for entertainment, industrial, and scientific applications.

  12. The PixFEL project: development of advanced X-ray pixel detectors for application at future FEL facilities

    International Nuclear Information System (INIS)

    Rizzo, G.; Batignani, G.; Bettarini, S.; Casarosa, G.; Forti, F.; Paladino, A.; Paoloni, E.; Comotti, D.; Grassi, M.; Lodola, L.; Malcovati, P.; Ratti, L.; Vacchi, C.; Fabris, L.; Manghisoni, M.; Re, V.; Traversi, G.; Morsani, F.; Betta, G.-F. Dalla; Pancheri, L.

    2015-01-01

    The PixFEL project aims to develop an advanced X-ray camera for imaging suited for the demanding requirements of next generation free electron laser (FEL) facilities. New technologies can be deployed to boost the performance of imaging detectors as well as future pixel devices for tracking. In the first phase of the PixFEL project, approved by the INFN, the focus will be on the development of the microelectronic building blocks, carried out with a 65 nm CMOS technology, implementing a low noise analog front-end channel with high dynamic range and compression features, a low power ADC and high density memory. At the same time PixFEL will investigate and implement some of the enabling technologies to assembly a seamless large area X-ray camera composed by a matrix of multilayer four-side buttable tiles. A pixel matrix with active edge will be developed to minimize the dead area of the sensor layer. Vertical interconnection of two CMOS tiers will be explored to build a four-side buttable readout chip with small pixel pitch and all the on-board required functionalities. The ambitious target requirements of the new pixel device are: single photon resolution, 1 to 10 4 photons @ 1 keV to 10 keV input dynamic range, 10-bit analog to digital conversion up to 5 MHz, 1 kevent in-pixel memory and 100 μm pixel pitch. The long term goal of PixFEL will be the development of a versatile X-ray camera to be operated either in burst mode (European XFEL), or in continuous mode to cope with the high frame rates foreseen for the upgrade phase of the LCLS-II at SLAC

  13. Projection radiography. Chapter 6

    Energy Technology Data Exchange (ETDEWEB)

    Poletti, J. L. [UNITEC Institute of Technology, Auckland (New Zealand)

    2014-09-15

    In its simplest form, X ray imaging is the collection of attenuation shadows that are projected from an ideal X ray point source on to an image receptor. This simple form is true for all X ray imaging modalities, including complex ones that involve source and receptor movement, such as computed tomography (CT). This simplified view, however, is made vastly more complex by the non-ideal point source, by the consequences of projecting a 3-D object on to a 2-D detector and by the presence of scattered radiation, generated within the patient, which will degrade any image that is captured.

  14. Skin reduction technique for correction of lateral deviation of the erect straight penis.

    Science.gov (United States)

    Shaeer, Osama

    2014-07-01

    Lateral deviation of the erect straight penis (LDESP) refers to a penis that despite being straight in the erect state, points laterally, yet can be directed forward manually without the use of force. While LDESP should not impose a negative impact on sexual function, it may have a negative cosmetic impact. This work describes skin reduction technique (SRT) for correction of LDESP. Counseling was offered to males with LDESP after excluding other abnormalities. Surgery was performed in case of failed counseling. In the erect state, the degree and direction of LDESP were noted. Skin on the base of the penis on the contralateral side of LDESP was excised from the base of the penis and the edges approximated to correct LDESP. Further excision was repeated if needed. The incision was closed in two layers. Long-term efficacy of SRT was the main outcome measure. Out of 183 males with LDESP, 66.7% were not sexually active. Counseling relieved 91.8% of cases. Fifteen patients insisted on surgery, mostly from among the sexually active where the complaint was mutual from the patient and partner. SRT resulted in full correction of the angle of erection in 12 cases out of 15. Two had minimal recurrence, and one had major recurrence indicating re-SRT. LDESP is more common a complaint among those who have not experienced coital relationship, and is mostly relieved by counseling. However, sexually active males with this complaint are more difficult to relieve by counseling. A minority of patients may opt for surgical correction. SRT achieves a forward erection in such patients, is minimally invasive, and relatively safe, provided the angle of erection can be corrected manually without force. Shaeer O. Skin reduction technique for correction of lateral deviation of the erect straight penis. © 2014 International Society for Sexual Medicine.

  15. Absorption of short-pulse electromagnetic energy by a resistively loaded straight wire

    International Nuclear Information System (INIS)

    Miller, E.K.; Deadrick, F.J.; Landt, J.A.

    1975-01-01

    Absorption of short-pulse electromagnetic energy by a resistively loaded straight wire is examined. Energy collected by the wire, load energy, peak load currents, and peak load voltages are found for a wide range of parameters, with particular emphasis on nuclear electromagnetic pulse (EMP) phenomena. A series of time-sequenced plots is used to illustrate pulse propagation on wires when loads and wire ends are encountered

  16. Optimizing the injection straight of PEP II asymmetric B Factory at SLAC

    International Nuclear Information System (INIS)

    Bulos, F.; Bloom, E.; Davies-White, W.; Donald, M.; Fairfield, K.; Fieguth, T.; Godfrey, G.; Holtzapple, R.; Hutton, A.; Loew, G.; Miller, R.; Sukiennicki, B.; Wen, H.; Ronan, M.

    1992-04-01

    The asymmetric energy PEP II B Factory proposed as an upgrade of PEP at the Stanford Linear Accelerator Center requires both a powerful low emittance source of e - e + and a very reliable and efficient injection system. The SLC linac fulfills the source requirement very well. We describe here the optimization of the optics of the injection straight to insure reliable and efficient injection

  17. Optimizing the injection straight of PEP II asymmetric B factory at SLAC

    International Nuclear Information System (INIS)

    Bulos, F.; Bloom, E.; Davies-White, W.; Donald, M.; Fairfield, K.; Fieguth, T.; Godfrey, G.; Holtzapple, R.; Hutton, A.; Loew, G.; Miller, R.; Sukiennicki, B.; Wen, H.

    1992-01-01

    The asymmetric energy PEP II B Factory proposed as an upgrade of PEP at the Stanford Linear Accelerator Center requires both a powerful low emittance source of e - e + and a very reliable and efficient injection system. The SLC linac fulfills the source requirement very well. We describe here the optimization of the optics of the injection straight to insure reliable and efficient injection

  18. Effect of cisplatin on proximal convoluted and straight segments of the rat kidney

    DEFF Research Database (Denmark)

    Daugaard, G; Holstein-Rathlou, N H; Leyssac, P P

    1988-01-01

    lithium clearance (CLi/Cin) and e-TT/OT was observed (from 270 +/- 32 to 387 +/- 60 microliters/min/g kidney weight, 0.202 +/- 0.03 to 0.340 +/- 0.06 and 0.415 +/- 0.02 to 0.497 +/- 0.02, respectively). These increases indicate an increased fluid delivery from both the proximal straight segment...

  19. Biplanar x-ray fluoroscopy for sacroiliac joint fusion.

    Science.gov (United States)

    Vanaclocha-Vanaclocha, Vicente; Verdú-López, Francisco; Sáiz-Sapena, Nieves; Herrera, Juan Manuel; Rivera-Paz, Marlon

    2016-07-01

    Chronic pain originating from the sacroiliac joint (SI) can cause severe dysfunction. Although many patients respond to conservative management with NSAIDs, some do need further treatment in the form of SI joint fusion (SIJF). To achieve safe and successful SIJF, intraoperative x-ray fluoroscopy is mandatory to avoid serious damages to nearby vascular and neural structures. Each step of the procedure has to be confirmed by anteroposterior (AP) and lateral projections. With a single-arm x-ray, the arch has to be moved back and forth for the AP and lateral projections, and this lengthens the procedure. To achieve the same results in less time, the authors introduced simultaneous biplanar fluoroscopy with 2 x-ray arches. After the patient is positioned prone with the legs spread apart in the so-called Da Vinci position, one x-ray arch for the lateral projection is placed at a right angle to the patient, and a second x-ray machine is placed with its arch between the legs of the patient. This allows simultaneous AP and lateral x-ray projections and, in the authors' hands, markedly speeds up the procedure. Biplanar fluoroscopy allows excellent AP and lateral projections to be made quickly at any time during the surgical procedure. This is particularly useful in cases of bilateral SI joint fusion if both sides are done at the same time. The video can be found here: https://youtu.be/TX5gz8c765M .

  20. Hydrodynamic shrinkage of liquid CO2 Taylor drops in a straight microchannel

    Science.gov (United States)

    Qin, Ning; Wen, John Z.; Ren, Carolyn L.

    2018-03-01

    Hydrodynamic shrinkage of liquid CO2 drops in water under a Taylor flow regime is studied using a straight microchannel (length/width ~100). A general form of a mathematical model of the solvent-side mass transfer coefficient (k s) is developed first. Based on formulations of the surface area (A) and the volume (V) of a general Taylor drop in a rectangular microchannel, a specific form of k s is derived. Drop length and speed are experimentally measured at three specified positions of the straight channel, namely, immediately after drop generation (position 1), the midpoint of the channel (position 2) and the end of the channel (position 3). The reductions of drop length (L x , x  =  1, 2, 3) from position 1 to 2 and down to 3 are used to quantify the drop shrinkage. Using the specific model, k s is calculated mainly based on L x and drop flowing time (t). Results show that smaller CO2 drops produced by lower flow rate ratios ({{Q}LC{{O2}}}/{{Q}{{H2}O}} ) are generally characterized by higher (nearly three times) k s and Sherwood numbers than those produced by higher {{Q}LC{{O2}}}/{{Q}{{H2}O}} , which is essentially attributed to the larger effective portion of the smaller drop contributing in the mass transfer under same levels of the flowing time and the surface-to-volume ratio (~104 m-1) of all drops. Based on calculated pressure drops of the segmented flow in microchannel, the Peng-Robinson equation of state and initial pressures of drops at the T-junction in experiments, overall pressure drop (ΔP t) in the straight channel as well as the resulted drop volume change are quantified. ΔP t from position 1-3 is by average 3.175 kPa with a ~1.6% standard error, which only leads to relative drop volume changes of 0.3‰ to 0.52‰.

  1. Hydrodynamic shrinkage of liquid CO2 Taylor drops in a straight microchannel.

    Science.gov (United States)

    Qin, Ning; Wen, John; Ren, Carolyn L

    2018-01-16

    Hydrodynamic shrinkage of liquid CO2 drops in water under a Taylor flow regime is studied using a straight microchannel (length/width ~ 100). A general form of a mathematical model of the solvent-side mass transfer coefficient (ks) is developed first. Based on formulations of the surface area (A) and the volume (V) of a general Taylor drop in a rectangular microchannel, a specific form of ks is derived. Drop length and speed are experimentally measured at three specified positions of the straight channel, namely, immediately after drop generation (position 1), the midpoint of the channel (position 2) and the end of the channel (position 3). The reductions of drop length (Lx, x = 1, 2, 3) from position 1 to 2 and down to 3 are used to quantify the drop shrinkage. Using the specific model, ks is calculated mainly based on Lx and drop flowing time (t). Results show that smaller CO2 drops produced by lower flow rate ratios (QLCO2/QH2O) are generally characterized by higher (nearly three times) ks and Sherwood numbers than those produced by higher QLCO2/QH2O, which is essentially attributed to the larger effective portion of the smaller drop contributing in the mass transfer under same levels of the flowing time and the surface-to-volume ratio (~ 104 m-1) of all drops. Based on calculated pressure drops of the segmented flow in microchannel, the Peng-Robinson equation of state (EOS) and initial pressures of drops at the T-junction in experiments, overall pressure drop (ΔPt) in the straight channel as well as the resulted drop volume change are quantified. ΔPt from position 1 to 3 is by average 3.175 kPa with a ~1.6% standard error, which only leads to relative drop volume changes of 0.3‰ to 0.52‰. © 2018 IOP Publishing Ltd.

  2. Prediction of the Flash Point of Binary and Ternary Straight-Chain Alkane Mixtures

    Directory of Open Access Journals (Sweden)

    X. Li

    2014-01-01

    Full Text Available The flash point is an important physical property used to estimate the fire hazard of a flammable liquid. To avoid the occurrence of fire or explosion, many models are used to predict the flash point; however, these models are complex, and the calculation process is cumbersome. For pure flammable substances, the research for predicting the flash point is systematic and comprehensive. For multicomponent mixtures, especially a hydrocarbon mixture, the current research is insufficient to predict the flash point. In this study, a model was developed to predict the flash point of straight-chain alkane mixtures using a simple calculation process. The pressure, activity coefficient, and other associated physicochemical parameters are not required for the calculation in the proposed model. A series of flash points of binary and ternary mixtures of straight-chain alkanes were determined. The results of the model present consistent experimental results with an average absolute deviation for the binary mixtures of 0.7% or lower and an average absolute deviation for the ternary mixtures of 1.03% or lower.

  3. A mathematical model for the motion analysis of embedded straight microcantilevers under a pressure-driven flow

    International Nuclear Information System (INIS)

    Ezkerra, A; Mayora, K; Ruano-López, J M; Wilson, P A

    2008-01-01

    A mathematical model that estimates the deflection of straight microcantilevers embedded in a microchannel under a pressure-driven flow at low Reynolds numbers is presented. The model makes use of the Schwarz–Christoffel mapping in order to couple the geometry of the structure and the flow passing around it. Therefore, it allows the determination of the most influential parameters and suitable modifications in order to achieve the desired performance. The model does not require specific knowledge of the flow conditions in the vicinity of the structure, which improves its practical use during the early stages of design. Estimations have been made for two straight cantilevers under a range of pressures. The results obtained show good agreement with measurements from experiments

  4. Finding the Quickest Straight-Line Trajectory for a Three-Wheeled Omnidirectional Robot under Input Voltage Constraints

    Directory of Open Access Journals (Sweden)

    Ki Bum Kim

    2015-01-01

    Full Text Available We provide an analytical solution to the problem of generating the quickest straight-line trajectory for a three-wheeled omnidirectional mobile robot, under the practical constraint of limited voltage. Applying the maximum principle to the geometric properties of the input constraints, we find that an optimal input vector of motor voltages has at least one extreme value when the orientation of the robot is fixed and two extreme values when rotation is allowed. We can find an explicit representation of the optimal vector for a motion under fixed orientation. We derive several properties of quickest straight-line trajectories and verify them through simulation. We show that the quickest trajectory when rotation is allowed is always faster than the quickest with fixed orientation.

  5. The PixFEL project: Progress towards a fine pitch X-ray imaging camera for next generation FEL facilities

    Energy Technology Data Exchange (ETDEWEB)

    Rizzo, G., E-mail: giuliana.rizzo@pi.infn.it [Università di Pisa, Dipartimento di Fisica, I-56127 Pisa (Italy); INFN, Sezione di Pisa, I-56127 Pisa (Italy); Batignani, G. [Università di Pisa, Dipartimento di Fisica, I-56127 Pisa (Italy); INFN, Sezione di Pisa, I-56127 Pisa (Italy); Benkechkache, M.A. [Università di Trento, Dipartimento di Ingegneria Industriale, I-38123 Trento (Italy); University Constantine 1, Department of Electronics in the Science and Technology Faculty, I-25017, Constantine (Algeria); Bettarini, S.; Casarosa, G. [Università di Pisa, Dipartimento di Fisica, I-56127 Pisa (Italy); INFN, Sezione di Pisa, I-56127 Pisa (Italy); Comotti, D. [Università di Pavia, Dipartimento di Ingegneria Industriale e dell' Informazione, I-27100 Pavia (Italy); INFN Sezione di Pavia, I-27100 Pavia (Italy); Dalla Betta, G.-F. [Università di Trento, Dipartimento di Ingegneria Industriale, I-38123 Trento (Italy); TIFPA INFN, I-38123 Trento (Italy); Fabris, L. [INFN Sezione di Pavia, I-27100 Pavia (Italy); Università di Bergamo, Dipartimento di Ingegneria e Scienze Applicate, I-24044 Dalmine (Italy); Forti, F. [Università di Pisa, Dipartimento di Fisica, I-56127 Pisa (Italy); INFN, Sezione di Pisa, I-56127 Pisa (Italy); Grassi, M.; Lodola, L.; Malcovati, P. [Università di Pavia, Dipartimento di Ingegneria Industriale e dell' Informazione, I-27100 Pavia (Italy); INFN Sezione di Pavia, I-27100 Pavia (Italy); Manghisoni, M. [INFN Sezione di Pavia, I-27100 Pavia (Italy); Università di Bergamo, Dipartimento di Ingegneria e Scienze Applicate, I-24044 Dalmine (Italy); and others

    2016-07-11

    The INFN PixFEL project is developing the fundamental building blocks for a large area X-ray imaging camera to be deployed at next generation free electron laser (FEL) facilities with unprecedented intensity. Improvement in performance beyond the state of art in imaging instrumentation will be explored adopting advanced technologies like active edge sensors, a 65 nm node CMOS process and vertical integration. These are the key ingredients of the PixFEL project to realize a seamless large area focal plane instrument composed by a matrix of multilayer four-side buttable tiles. In order to minimize the dead area and reduce ambiguities in image reconstruction, a fine pitch active edge thick sensor is being optimized to cope with very high intensity photon flux, up to 10{sup 4} photons per pixel, in the range from 1 to 10 keV. A low noise analog front-end channel with this wide dynamic range and a novel dynamic compression feature, together with a low power 10 bit analog to digital conversion up to 5 MHz, has been realized in a 110 μm pitch with a 65 nm CMOS process. Vertical interconnection of two CMOS tiers will be also explored in the future to build a four-side buttable readout chip with high density memories. In the long run the objective of the PixFEL project is to build a flexible X-ray imaging camera for operation both in burst mode, like at the European X-FEL, or in continuous mode with the high frame rates anticipated for future FEL facilities.

  6. The PixFEL project: Progress towards a fine pitch X-ray imaging camera for next generation FEL facilities

    International Nuclear Information System (INIS)

    Rizzo, G.; Batignani, G.; Benkechkache, M.A.; Bettarini, S.; Casarosa, G.; Comotti, D.; Dalla Betta, G.-F.; Fabris, L.; Forti, F.; Grassi, M.; Lodola, L.; Malcovati, P.; Manghisoni, M.

    2016-01-01

    The INFN PixFEL project is developing the fundamental building blocks for a large area X-ray imaging camera to be deployed at next generation free electron laser (FEL) facilities with unprecedented intensity. Improvement in performance beyond the state of art in imaging instrumentation will be explored adopting advanced technologies like active edge sensors, a 65 nm node CMOS process and vertical integration. These are the key ingredients of the PixFEL project to realize a seamless large area focal plane instrument composed by a matrix of multilayer four-side buttable tiles. In order to minimize the dead area and reduce ambiguities in image reconstruction, a fine pitch active edge thick sensor is being optimized to cope with very high intensity photon flux, up to 10"4 photons per pixel, in the range from 1 to 10 keV. A low noise analog front-end channel with this wide dynamic range and a novel dynamic compression feature, together with a low power 10 bit analog to digital conversion up to 5 MHz, has been realized in a 110 μm pitch with a 65 nm CMOS process. Vertical interconnection of two CMOS tiers will be also explored in the future to build a four-side buttable readout chip with high density memories. In the long run the objective of the PixFEL project is to build a flexible X-ray imaging camera for operation both in burst mode, like at the European X-FEL, or in continuous mode with the high frame rates anticipated for future FEL facilities.

  7. Final Report on DTRA Basic Research Project #BRCALL08-Per3-C-2-0006 "High-Z Non-Equilibrium Physics and Bright X-ray Sources with New Laser Targets"

    Energy Technology Data Exchange (ETDEWEB)

    Colvin, Jeffrey D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-06-01

    This project had two major goals. Final Goal: obtain spectrally resolved, absolutely calibrated x-ray emission data from uniquely uniform mm-scale near-critical-density high-Z plasmas not in local thermodynamic equilibrium (LTE) to benchmark modern detailed atomic physics models. Scientific significance: advance understanding of non-LTE atomic physics. Intermediate Goal: develop new nano-fabrication techniques to make suitable laser targets that form the required highly uniform non-LTE plasmas when illuminated by high-intensity laser light. Scientific significance: advance understanding of nano-science. The new knowledge will allow us to make x-ray sources that are bright at the photon energies of most interest for testing radiation hardening technologies, the spectral energy range where current x-ray sources are weak. All project goals were met.

  8. Shielded transient self-interaction of a bunch entering a circle from a straight path

    International Nuclear Information System (INIS)

    Li, R.; Bohn, C.L.; Bisognano, J.J.

    1997-01-01

    Recent developments in electron-gun and injector technologies enable production of short (mm-length), high-charge (nC-regime) bunches. In this parameter regime, the curvature effect on the bunch self-interaction, by way of coherent synchrotron radiation (CSR) and space-charge forces as the beam traverses magnet bends, may cause serious emittance degradation. In this paper, the authors study an electron bunch orbiting between two infinite, parallel conducting plates. The bunch moves on a trajectory from a straight path to a circular orbit and begins radiating. Transient effects, arising from CSR and space-charge forces generated from source particles both on the bend and on the straight path prior to the bend, are analyzed using Lienard-Wiechert fields, and their overall net effect is obtained. The influence of the plates on the transients is contrasted to their shielding of the steady-state radiated power. Results for emittance degradation induced by this self-interaction are also presented

  9. Making Schools Safe and Inclusive: Gay-Straight Alliances and School Climate in Ontario

    Science.gov (United States)

    Kitchen, Julian; Bellini, Christine

    2013-01-01

    Gay-straight alliances (GSAs) have become widespread in Ontario schools and, starting in 2012, all schools are required to permit students to form GSAs. While American research suggests that GSAs have a positive impact on school safety and inclusion, there is little research on the impact of GSAs in Canadian schools. This study, based on a survey…

  10. Darboux integrability and rational reversibility in cubic systems with two invariant straight lines

    Directory of Open Access Journals (Sweden)

    Dumitru Cozma

    2013-01-01

    Full Text Available We find conditions for a singular point O(0,0 of a center or a focus type to be a center, in a cubic differential system with two distinct invariant straight lines. The presence of a center at O(0,0 is proved by using the method of Darboux integrability and the rational reversibility.

  11. Use of Straight –Run Gasoline (Srg) as A Leaching Solvent for Oil ...

    African Journals Online (AJOL)

    A study was conducted on the use of straight-run gasoline (SRG) as an extraction solvent for the leaching of palm kernel to produce palm kernel oil (PKO). SRG is an intermediate product fraction in the second fraction of crude petroleum oil fractionation that has not undergone any purification process. It is intended as a ...

  12. Ray splitting in the reflection and refraction of surface acoustic waves in anisotropic solids.

    Science.gov (United States)

    Every, A G; Maznev, A A

    2010-05-01

    This paper examines the conditions for, and provides examples of, ray splitting in the reflection and refraction of surface acoustic waves (SAW) in elastically anisotropic solids at straight obstacles such as edges, surface breaking cracks, and interfaces between different solids. The concern here is not with the partial scattering of an incident SAW's energy into bulk waves, but with the occurrence of more than one SAW ray in the reflected and/or transmitted wave fields, by analogy with birefringence in optics and mode conversion of bulk elastic waves at interfaces. SAW ray splitting is dependent on the SAW slowness curve possessing concave regions, which within the constraint of wave vector conservation parallel to the obstacle allows multiple outgoing SAW modes for certain directions of incidence and orientation of obstacle. The existence of pseudo-SAW for a given surface provides a further channel for ray splitting. This paper discusses some typical material configurations for which SAW ray splitting occurs. An example is provided of mode conversion entailing backward reflection or negative refraction. Experimental demonstration of ray splitting in the reflection of a laser generated SAW in GaAs(111) is provided. The calculation of SAW mode conversion amplitudes lies outside the scope of this paper.

  13. Operation of a small-gap undulator on the NSLS X-ray Ring

    Energy Technology Data Exchange (ETDEWEB)

    Stefan, P.M.; Krinsky, S.; Rakowsky, G.; Solomon, L. [Brookhaven National Lab., Upton, NY (United States)

    1995-02-01

    The authors report results of an on-going experiment being carried out in the X13 straight section of the NSLS X-ray Ring which explores the limits of the operation of small-gap undulators. In particular, they discuss the operation of a 16 mm period small-gap undulator. At an electron beam current of 300 mA the variable gap vacuum chamber has been closed to an inner aperture of 3.8 mm with no effect on the electron beam lifetime. Measurements of the output radiation spectrum at a magnet gap of 7.5 mm are described.

  14. Destabilizing Anti-Gay Environments through Gay-Straight Alliances: Possibilities and Limitations through Shifting Discourses

    Science.gov (United States)

    Currie, Sean; Mayberry, Maralee; Chenneville, Tiffany

    2012-01-01

    Drawing upon research with Gay-Straight Alliance (GSA) advisors, high-school principals, and two district-level administrators, we examine the potential and limits of the safe-space discourse that encompasses the aims of GSAs. We argue that this discourse conceals heteronormative school environments, which supplies the groundwork for hostility…

  15. Charged Particle Dynamics in the Magnetic Field of a Long Straight Current-Carrying Wire

    Science.gov (United States)

    Prentice, A.; Fatuzzo, M.; Toepker, T.

    2015-01-01

    By describing the motion of a charged particle in the well-known nonuniform field of a current-carrying long straight wire, a variety of teaching/learning opportunities are described: 1) Brief review of a standard problem; 2) Vector analysis; 3) Dimensionless variables; 4) Coupled differential equations; 5) Numerical solutions.

  16. Straight and chopped DC performance data for a General Electric 5BY436A1 DC shunt motor with a General Electric EV-1 controller

    Science.gov (United States)

    Edie, P. C.

    1981-01-01

    Both straight and chopped dc motor performance data for a General Electric 5BY436A1 motor with a General Electric EV-1 controller is presented in tabular and graphical formats. Effects of motor temperature and operating voltage are also shown. The maximum motor efficiency is approximately 85% at low operating temperatures in the straight dc mode. Chopper efficiency can be assumed to be 95% under all operating conditions. For equal speeds, the motor operated in the chopped mode develops slightly more torque and draws more current than it does in the straight mode.

  17. On Helical Projection and Its Application in Screw Modeling

    Directory of Open Access Journals (Sweden)

    Riliang Liu

    2014-04-01

    Full Text Available As helical surfaces, in their many and varied forms, are finding more and more applications in engineering, new approaches to their efficient design and manufacture are desired. To that end, the helical projection method that uses curvilinear projection lines to map a space object to a plane is examined in this paper, focusing on its mathematical model and characteristics in terms of graphical representation of helical objects. A number of interesting projective properties are identified in regard to straight lines, curves, and planes, and then the method is further investigated with respect to screws. The result shows that the helical projection of a cylindrical screw turns out to be a Jordan curve, which is determined by the screw's axial profile and number of flights. Based on the projection theory, a practical approach to the modeling of screws and helical surfaces is proposed and illustrated with examples, and its possible application in screw manufacturing is discussed.

  18. The color of X-rays Spectral X-ray computed tomography using energy sensitive pixel detectors

    CERN Document Server

    Schioppa, Enrico Junior

    Energy sensitive X-ray imaging detectors are produced by connecting a semiconductor sensor to a spectroscopic pixel readout chip. In this thesis, the applicability of such detectors to X-ray Computed Tomography (CT) is studied. A prototype Medipix based silicon detector is calibrated using X-ray fluorescence. The charge transport properties of the sensor are characterized using a high energy beam of charged particles at the Super Proton Synchrotron (SPS) at the European Center for Nuclear Research (CERN). Monochromatic X-rays at the European Synchrotron Radiation Facility (ESRF) are used to determined the energy response function. These data are used to implement a physics-based CT projection operator that accounts for the transmission of the source spectrum through the sample and detector effects. Based on this projection operator, an iterative spectral CT reconstruction algorithm is developed by extending an Ordered Subset Expectation Maximization (OSEM) method. Subsequently, a maximum likelihood based algo...

  19. The relationship between X-ray residual stress near the crack and crack opening/closing behavior controlling fatigue crack propagation in Ti-6Al-4V alloy

    International Nuclear Information System (INIS)

    Torii, Tashiyuki; Toi, Norihiko; Nakano, Kohji; Honda, Kazuo

    1998-01-01

    Using the X-ray method of stress measurement for Ti-6Al-4V alloys, the residual stress near the crack was measured for annealed (AN) and solution treated and aged (STA) titanium alloys, under the condition that the measured X-ray stress was in satisfactory agreement with the applied stress under tension. The residual stress measured in the wake of the propagating fatigue crack, σ r , was compressive, resulting in a smaller crack opening displacement, COD, than theorized. The measured σ r and COD-values let us understand the fatigue crack propagation rate da/dN in terms of the effective stress intensity factor K eff . As a result, the da/dN under the same K eff -value was smaller in the AN specimen with zigzag crack growth than in the STA specimen with straight crack growth, although the da/dN-K eff relationship under various stress amplitudes was represented by a straight line in a log-log scale separately for the AN and STA specimens. (author)

  20. A unifying model for planform straightness of ripples and dunes in air and water

    Science.gov (United States)

    Rubin, David M.

    2012-01-01

    Geologists, physicists, and mathematicians have studied ripples and dunes for more than a century, but despite considerable effort, no general model has been proposed to explain perhaps the most fundamental property of their morphology: why are some bedforms straight, continuous, parallel, and uniform in planform geometry (i.e. two-dimensional) whereas others are irregular (three-dimensional)? Here we argue that physical coupling along the crest of a bedform is required to produce straight crests and that along-crest flow and sand transport provide effective physical mechanisms for that coupling. Ripples and dunes with the straightest and most continuous crests include longitudinal and oblique dunes in unidirectional flows, wave ripples, dunes in reversing flows, wind ripples, and ripples migrating along a slope. At first glance, these bedforms appear quite different (ripples and dunes; air and water; transverse, oblique, and longitudinal orientations relative to the net sand-transport direction), but they all have one property in common: a process that increases the amount of along-crest sand transport (that lengthens and straightens their crests) relative to the across-crest transport (that makes them migrate and take the more typical and more three-dimensional planform geometry). In unidirectional flows that produce straight bedforms, along-crest transport of sand is caused by along-crest flow (non-transverse bedform orientation), gravitational transport along an inclined crest, or ballistic splash in air. Bedforms in reversing flows tend to be straighter than their unidirectional counterparts, because reverse transport across the bedform crest reduces the net across-crest transport (that causes the more typical irregular geometry) relative to the along-crest transport (that smoothes and straightens planform geometry).

  1. X-Ray Diffraction Project Final Report, Fiscal Year 2006

    International Nuclear Information System (INIS)

    Dane V. Morgan

    2006-01-01

    An x-ray diffraction diagnostic system was developed for determining real-time shock-driven lattice parameter shifts in single crystals at the gas gun at TA-IV at Sandia National Laboratories (SNL). The signal-to-noise ratio and resolution of the system were measured using imaging plates as the detector and by varying the slit width. This report includes tests of the x-ray diffraction system using a phosphor coupled to a charge-coupled device (CCD) camera by a coherent fiber-optic bundle. The system timing delay was measured with a newly installed transistor-transistor logic (TTL) bypass designed to reduce the x-ray delay time. The axial misalignment of the Bragg planes was determined with respect to the optical axis for a set of eight LiF [lithium fluoride] crystals provided by SNL to determine their suitability for gas gun experiments

  2. Experimental and Modeling Damage Limits Study for Straight Ti-3A1-2.5V Tubes

    National Research Council Canada - National Science Library

    Gupta, Mool C; Lin, Yaomin; Ni, Kan; Wong, Teh-Hwa; Woodland, Kevin; Grose, Tim; Spidel, Tom; Stone, Bill; Yu, Michael; Taylor, Bob; Lei, Charles; Williams, Reanne

    2007-01-01

    To insure the safety of the V-22 aircraft over long period of operation, damage limits should be established for Ti alloy hydraulic tubes In a previous report, the damage limit results for straight...

  3. Raspberry Pi projects for kids

    CERN Document Server

    Bates, Daniel

    2014-01-01

    This tutorial contains all-important information about how to use your Raspberry Pi to develop any application you like. It is broken down into several action-packed projects, each containing easy-to-follow steps, just to show you how easy and fun computer programming can be!If you are someone with a big imagination and would like to dive straight into the realm of technology and computers, then this is the book for you. With only a Raspberry Pi and no prior experience required, you will be shown how to translate your ideas into computer programs, creating any game, tool, or animation you can

  4. Mechanochemical effect on swelling and drug release of natural polymer matrix tablets by X-ray computed tomography.

    Science.gov (United States)

    Hattori, Yusuke; Takaku, Tomomi; Otsuka, Makoto

    2018-03-25

    The relationships between the physicochemical properties of milled starch and drug release from tablets were investigated quantitatively using a drug release kinetic method and X-ray computed tomography (XCT). The samples were prepared from raw β-starch by milling in a planetary ball mill. The tablets, containing 5% theophylline (TH), 94% milled starch, and 1% magnesium stearate, were compressed at 6 kN. The drug-release and gel-forming processes were measured simultaneously using an original dissolution tester with an XCT instrument. Drug release from the tablet was delayed with increasing milling time, because the TH tablet formed a typical gel-layer on the outside of the tablet. The relationship between the crystallinity of milled starch and mean drug release time (MDT) for the TH tablets showed almost a straight inverse proportional relationship. The plots of MDT against area under the curve of the swelling ratio profiles of the TH tablets had a good straight line. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Large Eddy Simulation of turbulence induced secondary flows in stationary and rotating straight square ducts

    Science.gov (United States)

    Sudjai, W.; Juntasaro, V.; Juttijudata, V.

    2018-01-01

    The accuracy of predicting turbulence induced secondary flows is crucially important in many industrial applications such as turbine blade internal cooling passages in a gas turbine and fuel rod bundles in a nuclear reactor. A straight square duct is popularly used to reveal the characteristic of turbulence induced secondary flows which consists of two counter rotating vortices distributed in each corner of the duct. For a rotating duct, the flow can be divided into the pressure side and the suction side. The turbulence induced secondary flows are converted to the Coriolis force driven two large circulations with a pair of additional vortices on the pressure wall due to the rotational effect. In this paper, the Large Eddy Simulation (LES) of turbulence induced secondary flows in a straight square duct is performed using the ANSYS FLUENT CFD software. A dynamic kinetic energy subgrid-scale model is used to describe the three-dimensional incompressible turbulent flows in the stationary and the rotating straight square ducts. The Reynolds number based on the friction velocity and the hydraulic diameter is 300 with the various rotation numbers for the rotating cases. The flow is assumed fully developed by imposing the constant pressure gradient in the streamwise direction. For the rotating cases, the rotational axis is placed perpendicular to the streamwise direction. The simulation results on the secondary flows and the turbulent statistics are found to be in good agreement with the available Direct Numerical Simulation (DNS) data. Finally, the details of the Coriolis effects are discussed.

  6. Projection-slice theorem based 2D-3D registration

    NARCIS (Netherlands)

    Bom, van der M.J.; Pluim, J.P.W.; Homan, R.; Timmer, J.; Bartels, L.W.; Pluim, J.P.W.; Reinhardt, J.M.

    2007-01-01

    In X-ray guided procedures, the surgeon or interventionalist is dependent on his or her knowledge of the patient's specific anatomy and the projection images acquired during the procedure by a rotational X-ray source. Unfortunately, these X-ray projections fail to give information on the patient's

  7. Comparison of waveguide properties of curved versus straight planar elastic layers

    DEFF Research Database (Denmark)

    Zadeh, Maziyar Nesari; Sorokin, Sergey

    2013-01-01

    Dispersion equations are solved for the in-plane and anti-plane wave propagation in planar elastic layer with constant curvature. The classical Lamé formulation of displacements via elastic potentials is applied and appropriate simplifications are employed. The dispersion diagrams in each case...... are compared with their counterparts for a straight layer, e.g., the classical Rayleigh–Lamb solution. The curvature-induced symmetry-breaking effects are investigated for layers with symmetric boundary conditions. The role of curvature is also investigated in the cases, when the boundary conditions...

  8. Straight line foraging in yellow-eyed penguins: new insights into cascading fisheries effects and orientation capabilities of marine predators.

    Science.gov (United States)

    Mattern, Thomas; Ellenberg, Ursula; Houston, David M; Lamare, Miles; Davis, Lloyd S; van Heezik, Yolanda; Seddon, Philip J

    2013-01-01

    Free-ranging marine predators rarely search for prey along straight lines because dynamic ocean processes usually require complex search strategies. If linear movement patterns occur they are usually associated with travelling events or migratory behaviour. However, recent fine scale tracking of flying seabirds has revealed straight-line movements while birds followed fishing vessels. Unlike flying seabirds, penguins are not known to target and follow fishing vessels. Yet yellow-eyed penguins from New Zealand often exhibit directed movement patterns while searching for prey at the seafloor, a behaviour that seems to contradict common movement ecology theories. While deploying GPS dive loggers on yellow-eyed penguins from the Otago Peninsula we found that the birds frequently followed straight lines for several kilometres with little horizontal deviation. In several cases individuals swam up and down the same line, while some of the lines were followed by more than one individual. Using a remote operated vehicle (ROV) we found a highly visible furrow on the seafloor most likely caused by an otter board of a demersal fish trawl, which ran in a straight line exactly matching the trajectory of a recent line identified from penguin tracks. We noted high abundances of benthic scavengers associated with fisheries-related bottom disturbance. While our data demonstrate the acute way-finding capabilities of benthic foraging yellow-eyed penguins, they also highlight how hidden cascading effects of coastal fisheries may alter behaviour and potentially even population dynamics of marine predators, an often overlooked fact in the examination of fisheries' impacts.

  9. Straight line foraging in yellow-eyed penguins: new insights into cascading fisheries effects and orientation capabilities of marine predators.

    Directory of Open Access Journals (Sweden)

    Thomas Mattern

    Full Text Available Free-ranging marine predators rarely search for prey along straight lines because dynamic ocean processes usually require complex search strategies. If linear movement patterns occur they are usually associated with travelling events or migratory behaviour. However, recent fine scale tracking of flying seabirds has revealed straight-line movements while birds followed fishing vessels. Unlike flying seabirds, penguins are not known to target and follow fishing vessels. Yet yellow-eyed penguins from New Zealand often exhibit directed movement patterns while searching for prey at the seafloor, a behaviour that seems to contradict common movement ecology theories. While deploying GPS dive loggers on yellow-eyed penguins from the Otago Peninsula we found that the birds frequently followed straight lines for several kilometres with little horizontal deviation. In several cases individuals swam up and down the same line, while some of the lines were followed by more than one individual. Using a remote operated vehicle (ROV we found a highly visible furrow on the seafloor most likely caused by an otter board of a demersal fish trawl, which ran in a straight line exactly matching the trajectory of a recent line identified from penguin tracks. We noted high abundances of benthic scavengers associated with fisheries-related bottom disturbance. While our data demonstrate the acute way-finding capabilities of benthic foraging yellow-eyed penguins, they also highlight how hidden cascading effects of coastal fisheries may alter behaviour and potentially even population dynamics of marine predators, an often overlooked fact in the examination of fisheries' impacts.

  10. Small Woods Where I Met Myself : Jerry Uelsmann's departure from straight photography

    OpenAIRE

    Petersén, Moa

    2018-01-01

    In the article I investigate the differences between Ansel Adams' and Jerry Uelsmann's use of nature in their respective photography. Through their attitudes, approaches to, and involvement with nature their different relations to the photographic medium and the creative process unfold. Uelsmann's departure from the straight photographic tradition - that Ansel Adams came to symbolize - is in the article explained through an analysis of Uelsmann's and Adams' use of nature in their respective a...

  11. Non-destructive prediction of the drug content of an acetaminophen suppository by near-infrared spectroscopy and X-ray computed tomography.

    Science.gov (United States)

    Otsuka, Kuniko; Uchino, Tomohiro; Otsuka, Makoto

    2015-01-01

    The purpose of this study is to develop non-destructive methods to determine the drug content of suppositories using near-infrared (NIR) spectrometry and X-ray computed tomography (XCT). The suppository samples (acetaminophen content: 0, 100, 200, 300, 400 and 500 mg/suppository) consisted of acetaminophen powder and hard fat. NIR spectra of 18 standard suppository samples were recorded, and the data were divided into two wave number ranges, 4000-10 000 cm(-1) (LR), and 4280-6650 cm(-1) (SR). The best calibration model was determined to minimize the standard error of cross-validation (SECV) by the leave-one-out method in the partial least squares regression (PLS). Sliced XCT images of the suppositories were measured, and apparent density (AD) was evaluated using the image of the sample. The NIR models gave the best correlation coefficient constant (R) values, since the results for LR and SR gave straight lines with R of 0.9274 and 0.9707, respectively. The AD of the suppositories by XCT increased with increasing drug content, and the relationship between the AD and drug content had a straight line with R of 0.9958. Both NIR and X-ray CT performed accurate measurements of suppository samples through plastic packaging.

  12. Design Improvements and X-Ray Performance of a Time Projection Chamber Polarimeter for Persistent Astronomical Sources

    Science.gov (United States)

    Hill, Joanne E.; Black, J. Kevin; Emmett, Thomas J.; Enoto, Teruaki; Jahoda, Keith M.; Kaaret, Philip; Nolan, David S.; Tamagawa, Toru

    2014-01-01

    The design of the Time-Projection Chamber (TPC) Polarimeter for the Gravity and Extreme Magnetism Small Explorer (GEMS) was demonstrated to Technology Readiness Level 6 (TRL-6)3 and the flight detectors fabricated, assembled and performance tested. A single flight detector was characterized at the Brookhaven National Laboratory Synchrotron Light Source with polarized X-rays at 10 energies from 2.3-8.0 keV at five detector positions. The detector met all of the GEMS performance requirements. Lifetime measurements have shown that the existing flight design has 23 years of lifetime4, opening up the possibility of relaxing material requirements, in particular the consideration of the use of epoxy, to reduce risk elsewhere. We report on design improvements to the GEMS detector to enable a narrower transfer gap that, when operated with a lower transfer field, reduces asymmetries in the detector response. In addition, the new design reduces cost and risk by simplifying the assembly and reducing production time. Finally, we report on the performance of the narrow-gap detector in response to polarized and unpolarized X-rays.

  13. Prompt gamma-ray activation analysis (PGAA)

    International Nuclear Information System (INIS)

    Kern, J.

    1996-01-01

    The paper deals with a brief description of the principles of prompt gamma-ray activation analysis (PGAA), with the detection of gamma-rays, the PGAA project at SINQ and with the expected performances. 8 figs., 3 tabs., 10 refs

  14. Prompt gamma-ray activation analysis (PGAA)

    Energy Technology Data Exchange (ETDEWEB)

    Kern, J [Fribourg Univ. (Switzerland). Inst. de Physique

    1996-11-01

    The paper deals with a brief description of the principles of prompt gamma-ray activation analysis (PGAA), with the detection of gamma-rays, the PGAA project at SINQ and with the expected performances. 8 figs., 3 tabs., 10 refs.

  15. Small-gap undulator experiment on the NSLS X-ray Ring

    International Nuclear Information System (INIS)

    Stefan, P.M.; Krinsky, S.; Rakowsky, G.; Solomon, L.

    1995-01-01

    We report results of an on-going experiment being carried out in the X13 straight section of the NSLS X-ray Ring which explores the limits of the operation of small-gap undulators. In particular, we discuss measurements of stored electron beam lifetime as a function of the vertical aperture presented by a 4-jaw scraper or a variable-aperture vacuum vessel. At an electron beam current of 300 mA the variable-aperture vacuum chamber was closed to an inner aperture of 3.8 mm with no effect on the electron beam lifetime. Measurements of the output radiation spectrum of a 16 mm period undulator at a magnet gap of 7.5 mm are also described

  16. X-ray microscopy in Aarhus

    International Nuclear Information System (INIS)

    Uggerhoej, Erik; Abraham-Peskir, Joanna V.

    2000-01-01

    The Aarhus imaging soft X-ray microscope is now a busy multi-user facility. The optical set-up will be described and project highlights discussed. a) Metal-induced structural changes in whole cells in solution. The effects of aluminum, copper, nickel and zinc on protozoa investigated by using a combination of light microscopy, confocal scanning laser microscopy and X-ray microscopy. b) Botanical studies by X-ray microscopy used to compliment electron microscopy studies. c) Sludge morphology and iron precipitation in Danish freshwater plants by combining X-ray, scanning electron and transmission electron microscopy

  17. Capturing the most energetic cosmic rays

    International Nuclear Information System (INIS)

    Mantsch, P.

    1999-01-01

    The methods of energy measurement applied to the most energetic cosmic rays are described. The rays are so rare that two gigantic systems of detectors are proposed to detect at least some of them (the Pierre Auger Project ). (Z.J.)

  18. Thoracolumbar movement in sound horses trotting in straight lines in hand and on the lunge and the relationship with hind limb symmetry or asymmetry.

    Science.gov (United States)

    Greve, L; Pfau, T; Dyson, S

    2017-02-01

    Equine movement symmetry is changed when turning, which may induce alterations in thoracolumbosacral kinematics; however, this has not previously been investigated. Our objectives were to document thoracolumbar movement in subjectively sound horses comparing straight lines with circles on both reins and to relate these observations to the objectively determined symmetry/asymmetry of hindlimb gait. Fourteen non-lame horses were assessed prospectively in a non-random, cross-sectional survey. The horses were trotted in straight lines and lunged on both reins and inertial sensor data collected at landmarks: withers, T13 and T18, L3, tubera sacrale, and left and right tubera coxae. Data were processed using published methods; angular motion range of motion (ROM; flexion-extension, axial rotation, lateral bending) and translational ROM (dorsoventral and lateral) and symmetry within each stride were assessed. The dorsoventral movement of the back exhibited a sinusoidal pattern with two oscillations per stride. Circles induced greater asymmetry in dorsoventral movement within each stride (mean ± standard deviation, up to 9 ± 6%) compared with straight lines (up to 6 ± 6%). The greatest amplitude of dorsoventral movement (119 ± 14 mm in straight lines vs. 126 ± 20 mm in circles) occurred at T13. Circles induced greater flexion-extension ROM (>1.3°; P = 0.002), lateral bending (>16°; P 16 mm; P = 0.002) compared with straight lines. Circles induced a movement pattern similar to an inside hindlimb lameness, which was significantly associated with the circle-induced greater asymmetry of dorsoventral movement of the thoracolumbar region (P = 0.03). Moving in a circle induces measurable changes in thoracolumbar movement compared with moving in straight lines, associated with alterations in the hindlimb gait. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Modelling of flexibles for structural analysis of short straight section of Large Hadron Collider

    International Nuclear Information System (INIS)

    Abhay Kumar; Dutta, Subhajit; Dwivedi, Jishnu; Soni, H.C.

    2003-01-01

    Short Straight Section (SSS) of Large hadron Collider (LRCM) is a 8-meter long structure with a diameter of 1 meter and it houses a twin quadrupole. The cryogens are fed to the Sass through a jumper connection between Cryogenic Distribution Line (QRL) and SSS. The bus bars travel through interconnection bellows to adjoining magnets. CAT is studying the structural behavior of cold mass and the cryostat when subjected to various forces imposed on the SSS under various operating conditions of LHC machine including realignment required to compensate local sinking of the floor of the tunnel during the LHC machine's lifetime. CAT did calculation of reaction forces and moments on the Short Straight Section due to presence of jumper connection last year after the experimental verification of finite element model at CERN. Subsequently, a unified Fe model consisting of cold mass, cold feet, vacuum vessel, main vacuum vessel bellows (large sleeves), magnet interconnects, jumper connection, service module and precision motion jacks is being developed for studying the structural behaviour. (author)

  20. Straight-leg rasing in 'short hamstrings'. An experimental study of muscle elasticy and defense reactions.

    NARCIS (Netherlands)

    Göeken, Ludwig Nanno Hiltjo

    1988-01-01

    The central guestion asked in this thesis is whether an Experimental Straight-Leg Raising test (E.S.L.R.) can contribute to the solution of a diagnostical problem frequently encountered in rehabilitation medicine. It concerns the determination of the cause of the movement restriction in patients who

  1. 26 CFR 1.9001-1 - Change from retirement to straight-line method of computing depreciation.

    Science.gov (United States)

    2010-04-01

    ... of computing depreciation. 1.9001-1 Section 1.9001-1 Internal Revenue INTERNAL REVENUE SERVICE....9001-1 Change from retirement to straight-line method of computing depreciation. (a) In general. The... of deductions for the depreciation of those roadway assets which are defined in this section as...

  2. AUTOMATIC GLOBAL REGISTRATION BETWEEN AIRBORNE LIDAR DATA AND REMOTE SENSING IMAGE BASED ON STRAIGHT LINE FEATURES

    Directory of Open Access Journals (Sweden)

    Z. Q. Liu

    2018-04-01

    Full Text Available An automatic global registration approach for point clouds and remote sensing image based on straight line features is proposed which is insensitive to rotational and scale transformation. First, the building ridge lines and contour lines in point clouds are automatically detected as registration primitives by integrating region growth and topology identification. Second, the collinear condition equation is selected as registration transformation function which is based on rotation matrix described by unit quaternion. The similarity measure is established according to the distance between the corresponding straight line features from point clouds and the image in the same reference coordinate system. Finally, an iterative Hough transform is adopted to simultaneously estimate the parameters and obtain correspondence between registration primitives. Experimental results prove the proposed method is valid and the spectral information is useful for the following classification processing.

  3. X-ray counterpart candidates for six new γ-ray pulsars

    Science.gov (United States)

    Zyuzin, Dmitry A.; Karpova, Anna V.; Shibanov, Yuriy A.

    2018-05-01

    Using archival X-ray data, we have found point-like X-ray counterpart candidates positionally coincident with six γ-ray pulsars discovered recently in the Fermi Gamma-ray Space Telescope data by the Einstein@Home project. The candidates for PSRs J0002+6216, J0554+3107, J1844-0346, and J1105-6037 are detected with Swift, and those for PSRs J0359+5414 and J2017+3625 are detected with Chandra. Despite a low count statistics for some candidates, assuming plausible constraints on the absorbing column density towards the pulsars, we show that X-ray spectral properties for all of them are consistent with those observed for other pulsars. J0359+5414 is the most reliably identified object. We detect a nebula around it, whose spectrum and extent suggest that this is a pulsar wind nebula powered by the pulsar. Associations of J0002+6216 and J1844-0346 with supernova remnants CTB 1 and G28.6-0.1 are proposed.

  4. Straight choices

    CERN Multimedia

    2001-01-01

    The HEP community is already discussing what kind of projects will take over from the Tevatron and LHC in around 2020. There is general agreement that the next collider must be a truly international collaboration, there is much less agreement on where it will be built. The most important consideration though is that the best possible machine is built Somewhere in the world (1 page editorial).

  5. Perceptions of a Gay-Straight Alliance Club Ban: School Counselors and Advocacy for LGBTQQ Students

    Science.gov (United States)

    Lassiter, Pamela S.; Sifford, Amy McCarthy

    2015-01-01

    This phenomenological inquiry explored the experiences and reactions of five school counselors who worked in a school that banned a Gay-Straight Alliance club. Specifically, the authors examined how counselors' perceptions of the ban influenced their advocacy for LGBTQQ students. The results of semi-structured interviews revealed one overarching…

  6. Cosmic ray studies on the ISS using SSNTD, BRADOS projects, 2001–2003

    CERN Document Server

    Pálfalvia, J K; Akatov, Y; Sajó-Bohus, L; Eördögh, I

    2005-01-01

    The BRADOS 1–3 projects were organised by the Russian Space Agency (RZA) between 2001 and 2003. The aim was to study the contribution of the primary galactic cosmic rays and of the secondary particles to the dose received by the crew of the International Space Station (ISS). Several laboratories participated in these experiments. Two different stacks (constructed by the team of the Atomic Energy Research Institute, AERI, Budapest, Hungary) composed of solid-state nuclear track detectors (SSNTD) were exposed inside the Service Module at different locations. The calibrations were made at the CERN high-energy neutron reference field named CERF (Geneva, Swiss). Applying a multiple track etching technique (2–20 h etching time) and a sophisticated image analyser, the secondary neutron dose was deduced. The composition of stacks, the evaluation methods and the results will be presented here or referenced to previous papers.

  7. X-ray electromagnetic application technology

    International Nuclear Information System (INIS)

    2011-01-01

    The investigating committee aimed at research on electromagnetic fields in functional devices and X-ray fibers for efficient coherent X-ray generation and their material science, high-precision manufacturing, particularly for X-ray electromagnetic application technology from January 2006 to December 2008. In this report, we describe our research results, in particular, on the topics of synchrotron radiation and free-electron laser, Saga Synchrotron Project, X-ray waveguides and waveguide-based lens-less hard-X-ray imaging, X-ray nanofocusing for capillaries and zone plates, dispersion characteristics in photonics crystal consisting of periodic atoms for nanometer waveguides, electromagnetic characteristics of grid structures for scattering fields of nano-meter electromagnetic waves and X-rays, FDTD parallel computing of fundamental scattering and attenuation characteristics of X-ray for medical imaging diagnosis, orthogonal relations of electromagnetic fields including evanescent field in dispersive medium. (author)

  8. Matrix inversion tomosynthesis improvements in longitudinal x-ray slice imaging

    International Nuclear Information System (INIS)

    Dobbines, J.T. III.

    1990-01-01

    This patent describes a tomosynthesis apparatus. It comprises: an x-ray tomography machine for producing a plurality of x-ray projection images of a subject including an x-ray source, and detection means; and processing means, connected to receive the plurality of projection images, for: shifting and reconstructing the projection x-ray images to obtain a tomosynthesis matrix of images T; acquiring a blurring matrix F having components which represent out-of-focus and in-focus components of the matrix T; obtaining a matrix P representing only in-focus components of the imaged subject by solving a matrix equation including the matrix T and the matrix F; correcting the matrix P for low spatial frequency components; and displaying images indicative of contents of the matrix P

  9. On proton CT reconstruction using MVCT-converted virtual proton projections

    Energy Technology Data Exchange (ETDEWEB)

    Wang Dongxu; Mackie, T. Rockwell; Tome, Wolfgang A. [Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin 53705 and Department of Radiation Oncology, University of Iowa Hospitals and Clinics, Iowa City, Iowa 52242 (United States); Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin 53705 and Morgridge Institute of Research, University of Wisconsin, Madison, Wisconsin 53715 (United States); Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin 53705 and Oncophysics Institute, Albert Einstein College of Medicine, Yeshiva University, Bronx, New York 10461 (United States)

    2012-06-15

    Purpose: To describe a novel methodology of converting megavoltage x-ray projections into virtual proton projections that are otherwise missing due to the proton range limit. These converted virtual proton projections can be used in the reconstruction of proton computed tomography (pCT). Methods: Relations exist between proton projections and multispectral megavoltage x-ray projections for human tissue. Based on these relations, these tissues can be categorized into: (a) adipose tissue; (b) nonadipose soft tissues; and (c) bone. These three tissue categories can be visibly identified on a regular megavoltage x-ray computed tomography (MVCT) image. With an MVCT image and its projection data available, the x-ray projections through heterogeneous anatomy can be converted to the corresponding proton projections using predetermined calibration curves for individual materials, aided by a coarse segmentation on the x-ray CT image. To show the feasibility of this approach, mathematical simulations were carried out. The converted proton projections, plotted on a proton sinogram, were compared to the simulated ground truth. Proton stopping power images were reconstructed using either the virtual proton projections only or a blend of physically available proton projections and virtual proton projections that make up for those missing due to the range limit. These images were compared to a reference image reconstructed from theoretically calculated proton projections. Results: The converted virtual projections had an uncertainty of {+-}0.8% compared to the calculated ground truth. Proton stopping power images reconstructed using a blend of converted virtual projections (48%) and physically available projections (52%) had an uncertainty of {+-}0.86% compared with that reconstructed from theoretically calculated projections. Reconstruction solely from converted virtual proton projections had an uncertainty of {+-}1.1% compared with that reconstructed from theoretical projections

  10. On proton CT reconstruction using MVCT-converted virtual proton projections

    International Nuclear Information System (INIS)

    Wang Dongxu; Mackie, T. Rockwell; Tomé, Wolfgang A.

    2012-01-01

    Purpose: To describe a novel methodology of converting megavoltage x-ray projections into virtual proton projections that are otherwise missing due to the proton range limit. These converted virtual proton projections can be used in the reconstruction of proton computed tomography (pCT). Methods: Relations exist between proton projections and multispectral megavoltage x-ray projections for human tissue. Based on these relations, these tissues can be categorized into: (a) adipose tissue; (b) nonadipose soft tissues; and (c) bone. These three tissue categories can be visibly identified on a regular megavoltage x-ray computed tomography (MVCT) image. With an MVCT image and its projection data available, the x-ray projections through heterogeneous anatomy can be converted to the corresponding proton projections using predetermined calibration curves for individual materials, aided by a coarse segmentation on the x-ray CT image. To show the feasibility of this approach, mathematical simulations were carried out. The converted proton projections, plotted on a proton sinogram, were compared to the simulated ground truth. Proton stopping power images were reconstructed using either the virtual proton projections only or a blend of physically available proton projections and virtual proton projections that make up for those missing due to the range limit. These images were compared to a reference image reconstructed from theoretically calculated proton projections. Results: The converted virtual projections had an uncertainty of ±0.8% compared to the calculated ground truth. Proton stopping power images reconstructed using a blend of converted virtual projections (48%) and physically available projections (52%) had an uncertainty of ±0.86% compared with that reconstructed from theoretically calculated projections. Reconstruction solely from converted virtual proton projections had an uncertainty of ±1.1% compared with that reconstructed from theoretical projections. If

  11. FEM simulation of a friction testing method based on combined forward conical can-backward straight can extrusion

    DEFF Research Database (Denmark)

    Nakamura, T; Bay, Niels

    1998-01-01

    A new friction testing method based on combined forward conical can-backward straight can extrusion is proposed in order to evaluate friction characteristics in severe metal forming operations. By this method the friction coefficient along the conical punch surface is determined knowing...... the friction coefficient along the die wall. The latter is determined by a combined forward and backward can extrusion of straight cans. Calibration curves determining the relationship between punch travel, can heights, and friction coefficient for the two rests are calculated based on a rigid-plastic FEM...... analysis. Experimental friction tests are carried out in a mechanical press with aluminium alloy A6061 as the workpiece material and different kinds of lubricants. They confirm that the theoretical analysis results irt reasonable values for the friction coefficient....

  12. Heterodyne grating interferometer based on a quasi-common-optical-path configuration for a two-degrees-of-freedom straightness measurement

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ju-Yi; Hsieh, Hung-Lin; Lerondel, Gilles; Deturche, Regis; Lu, Mini-Pei; Chen, Jyh-Chen

    2011-03-20

    We present a heterodyne grating interferometer based on a quasi-common-optical-path (QCOP) design for a two-degrees-of-freedom (DOF) straightness measurement. Two half-wave plates are utilized to rotate the polarizations of two orthogonally polarized beams. The grating movement can be calculated by measuring the phase difference variation in each axis. The experimental results demonstrate that our method has the ability to measure two-DOF straightness and still maintain high system stability. The proposed and demonstrated method, which relies on heterodyne interferometric phase measurement combined with the QCOP configuration, has the advantages of high measurement resolution, relatively straightforward operation, and high system stability.

  13. Computed tomography for light materials using a monochromatic X-ray beam produced by parametric X-ray radiation

    Energy Technology Data Exchange (ETDEWEB)

    Hayakawa, Y., E-mail: yahayak@lebra.nihon-u.ac.jp [Laboratory for Electron Beam Research and Application, Nihon University, Narashinodai 7-24-1, Funabashi 274-8501 (Japan); Hayakawa, K.; Inagaki, M. [Laboratory for Electron Beam Research and Application, Nihon University, Narashinodai 7-24-1, Funabashi 274-8501 (Japan); Kaneda, T. [Nihon University School of Dentistry at Matsudo, Sakaecho-Nishi 2-870-1, Matsudo 271-8587 (Japan); Nakao, K.; Nogami, K. [Laboratory for Electron Beam Research and Application, Nihon University, Narashinodai 7-24-1, Funabashi 274-8501 (Japan); Sakae, T. [Nihon University School of Dentistry at Matsudo, Sakaecho-Nishi 2-870-1, Matsudo 271-8587 (Japan); Sakai, T.; Sato, I. [Laboratory for Electron Beam Research and Application, Nihon University, Narashinodai 7-24-1, Funabashi 274-8501 (Japan); Takahashi, Y. [Institute of Materials Structure Science, High Energy Accelerator Research Organization (KEK), Oho, Tsukuba 305-8501 (Japan); Tanaka, T. [Laboratory for Electron Beam Research and Application, Nihon University, Narashinodai 7-24-1, Funabashi 274-8501 (Japan)

    2013-08-15

    Computed tomography (CT) for light materials such as soft biological tissues was performed using a monochromatic X-ray beam provided by a parametric X-ray radiation (PXR) source at the Laboratory for Electron Beam Research and Application (LEBRA) of Nihon University. Using a high-efficiency flat panel detector (FPD), each projection image for CT was taken with exposure times of 5 or 10 s, and 60–360 projection images in each run were obtained with total measurement time of 5 min to 1 h. CT images were obtained from the projection images using the conventional calculation method. The typical tomograms obtained had sharp outlines, which are likely attributable to the propagation-based phase contrast.

  14. Comparison of coupled mode theory and FDTD simulations of coupling between bent and straight optical waveguides

    NARCIS (Netherlands)

    Bertolotti, M.; Symes, W.W.; Stoffer, Remco; Hiremath, K.R.; Driessen, A.; Michelotti, F; Hammer, Manfred

    Analysis of integrated optical cylindrical microresonators involves the coupling between a straight waveguide and a bent waveguide. Our (2D) variant of coupled mode theory is based on analytically represented mode profiles. With the bend modes expressed in Cartesian coordinates, coupled mode

  15. Imaging X-Ray Polarimetry Explorer (IXPE) Risk Management

    Science.gov (United States)

    Alexander, Cheryl; Deininger, William D.; Baggett, Randy; Primo, Attina; Bowen, Mike; Cowart, Chris; Del Monte, Ettore; Ingram, Lindsey; Kalinowski, William; Kelley, Anthony; hide

    2018-01-01

    The Imaging X-ray Polarimetry Explorer (IXPE) project is an international collaboration to build and fly a polarization sensitive X-ray observatory. The IXPE Observatory consists of the spacecraft and payload. The payload is composed of three X-ray telescopes, each consisting of a mirror module optical assembly and a polarization-sensitive X-ray detector assembly; a deployable boom maintains the focal length between the optical assemblies and the detectors. The goal of the IXPE Mission is to provide new information about the origins of cosmic X-rays and their interactions with matter and gravity as they travel through space. IXPE will do this by exploiting its unique capability to measure the polarization of X-rays emitted by cosmic sources. The collaboration for IXPE involves national and international partners during design, fabrication, assembly, integration, test, and operations. The full collaboration includes NASA Marshall Space Flight Center (MSFC), Ball Aerospace, the Italian Space Agency (ASI), the Italian Institute of Astrophysics and Space Planetology (IAPS)/Italian National Institute of Astrophysics (INAF), the Italian National Institute for Nuclear Physics (INFN), the University of Colorado (CU) Laboratory for Atmospheric and Space Physics (LASP), Stanford University, McGill University, and the Massachusetts Institute of Technology. The goal of this paper is to discuss risk management as it applies to the IXPE project. The full IXPE Team participates in risk management providing both unique challenges and advantages for project risk management. Risk management is being employed in all phases of the IXPE Project, but is particularly important during planning and initial execution-the current phase of the IXPE Project. The discussion will address IXPE risk strategies and responsibilities, along with the IXPE management process which includes risk identification, risk assessment, risk response, and risk monitoring, control, and reporting.

  16. The Effect of Scala Tympani Morphology on Basilar Membrane Contact With a Straight Electrode Array: A Human Temporal Bone Study.

    Science.gov (United States)

    Verberne, Juul; Risi, Frank; Campbell, Luke; Chambers, Scott; O'Leary, Stephen

    2017-01-01

    Scala tympani morphology influences the insertion dynamics and intra-scalar position of straight electrode arrays. Hearing preservation is the goal of cochlear implantation with current thin straight electrode arrays. These hug the lateral wall, facilitating full, atraumatic insertions. However, most studies still report some postoperative hearing loss. This study explores the influence of scala tympani morphology on array position relative to the basilar membrane and its possible contribution to postoperative hearing loss. Twenty-six fresh-frozen human temporal bones implanted with a straight electrode array were three-dimensionally reconstructed from micro-photographic histological sections. Insertion depth and the proximity between the array and basilar membrane were recorded. Lateral wall shape was quantified as a curvature ratio. Insertion depths ranged from 233 to 470 degrees. The mean first point of contact between the array and basilar membrane was 185 degrees; arrays tended to remain in contact with the membrane after first contacting it. Eighty-nine and 93% of arrays that reached the upper basal (>240-360 degrees) and second (>360-720 degrees) turns respectively contacted the basilar membrane in these regions. Scalar wall curvature ratio decreased significantly (the wall became steeper) from the basal to second turns. This shift correlated with a reduced distance between the array and basilar membrane. Scala tympani morphology influences the insertion dynamics and intra-scalar position of a straight electrode array. In addition to gross trauma of cochlear structures, contact between the array and basilar membrane and how this impacts membrane function should be considered in hearing preservation cases.

  17. A “Swingable” straight-chain affinity molecule immobilized on a semi-conductor electrode for photo-excited current-based molecular sensing

    International Nuclear Information System (INIS)

    Takatsuji, Yoshiyuki; Wakabayashi, Ryo; Sakakura, Tatsuya; Haruyama, Tetsuya

    2015-01-01

    The molecular affinities of biomolecules have found applications in the areas of clinical diagnostics, drug discovery, as well as allied fields of study. An affinity sensor is a unique in situ assay tool, which is valuable and convenient in practical situations. In this study, we designed a photo-excitable molecular interface with an affinity domain and fabricated with a “swingable” straight-chain affinity molecule immobilized on a semi-conductor electrode (SCE). The straight-chain affinity molecule possessed a photo-excitable dye at one end and was bound to the SCE surface at the other by the EC tag method, which was developed previously. A straight-chain molecule is too long to transfer electrons from the photo-excited dye to the conduction band of the SCE. However, the straight-chain molecule was designed with a “swing” structure, which made the transfer of electrons possible. The central region of the chain molecule has an affinity to the activated estrogen receptor (ER). When the activated ER bound to the affinity region, the molecular lost its swingable function, the electron transfer from the photo-excited dye to the SCE was consequently suppressed. Based on the unique swingable molecular interface, the affinity sensor can be used to determine the in situ concentration of endocrine disrupter ESTROGEN (17β-estradiol) at concentrations ranging from 2 to 10 nM with very good reproducibility. The superior assay reproducibility is responsible for the success of the EC tag method, which is a quantitative method for immobilizing molecules on SCE.

  18. Straight cylindrical seal for high-performance turbomachines

    Science.gov (United States)

    Hendricks, Robert C.

    1987-01-01

    A straight cylindrical seal configuration representing the seal for a high-performance turbopump (e.g., the space shuttle main engine fuel pump) was tested under static (nonrotating) conditions. The test data included critical mass flux and pressure profiles over a wide range of inlet temperatures and pressures for fluid nitrogen and fluid hydrogen with the seal in concentric and fully eccentric positions. The critical mass fluxes (or leakage rates) for the concentric and fully eccentric configurations were nearly the same when based on stagnation conditions upstream of the seal. The fully eccentric configuration pressure profiles of the gas and liquid were different. Further, the pressure differences between the maximum and the minimum clearance positions were highly dependent on the geometric conditions, the temperature, and the absolute pressure at both the inlet and the exit. The pressure differences were greatest in the inlet region. The results, although complex, tend to follow the corresponding-states principles for critical flows. Gaseous injection near the seal exit plane significantly altered the pressure profiles and could be used to control turbomachine instabilities.

  19. Scintillation investigation of the straight back syndrome

    International Nuclear Information System (INIS)

    Ebaid, M.; Serro Azul, L.G.; Kedor, H-H.; Papaleo Netto, M.; Mignone, C.A.; Carvalho, N. de

    1976-01-01

    Scintigraphic study of the lungs was undertaken in 17 patients with the straight back syndrome divided in three groups: I. mild form; II. moderate form and III. severe form. The results showed that: a) there is a decreased flow through the pulmonary arteries; b) bilateral morphological alterations are most common (64.6%); c) the compression of the chest cause an increased cardiac silhouette in groups II (22.2%) and III (50%) besides widening of the mediastinum in all groups (25%, 44.4% and 75%, respectively); d. functional restriction is moderate in 61.5% and severe in 38.4% of the patients in the first two groups; in group III, moderate restriction is observed in 75% of the patients and severe restriction in 25%. Results indicate that the alterations observed in the scintigraphic study of the strainght back syndrome are caused by the effects of the deformed chest on the arterial perfusion of the lung. However, the severity of the anomaly and the decrease in the pulmonary circulation could not be correlated statistically [pt

  20. Installation and Quality Assurance of the Interconnections between Cryo-assemblies of the LHC Long Straight Sections

    CERN Document Server

    Garion, C; Tock, J P

    2006-01-01

    The interconnections between the cryomagnets and cryogenic utilities in the LHC long Straight Sections constitute the last machine installation activity. They are ensuring continuity of the beam and insulation vacuum systems, cryogenic fluid and electrical circuits and thermal insulation. The assembly is carried out in a constraining tunnel environment with restricted space. Therefore, the assembly sequence has to be well defined and specific tests have to be performed during the interconnection work to secure the reliability of the system and thus to ensure the global accelerator availability. The LHC has 8 long straight insertion zones composed of special cryomagnets involving specific interconnection procedures and QA plans. The aim of this paper is to present the installation and quality assurance procedures implemented for the LHC LSS interconnections. Technologies such as manual and automatic welding and resistive soldering will be described as well as the different quality controls, such as visual and ...

  1. The active straight leg raising test and mobility of the pelvic joints

    OpenAIRE

    Mens, J. M. A.; Vleeming, Andry; Snijders, Chris J.; Stam, Henk J.; Ginai, Abida Z.

    1999-01-01

    Objective signs to assess impairment in patients who are disabled by peripartum pelvic girdle pain hardly exist. The purpose of this study was to develop a clinical test to quantify and qualify disability in these patients. The study examined the relationship between impaired active straight leg raising (ASLR) and mobility of pelvic joints in patients with peripartum pelvic girdle pain, focusing on (1) the reduction of impairment of ASLR when the patient was wearing a pelvic belt, and (2) mot...

  2. Advantages and disadvantages of straight-lined and nonstraight-lined organizations at the airway facilities training division of the Federal Aviation Administration Academy

    Science.gov (United States)

    McMullen, Jessie L.

    Scope and method of study. This study describes the advantages and the disadvantages of straight-lined and nonstraight-lined organizations at the MMAC FAA Academy. The primary focus will be on the AF division within the FAA Academy. This study will assist in making sound decisions about which structure is better at the present time. Others who read this research will gain an awareness of advantages and disadvantages of each structure. The reason for focusing primarily on individuals from the FAA is because of their experience in straight-line and nonstraight-line organizations. Data were collected during the study and analyzed to determine what the majority of the candidates thought about the structure. Findings and conclusions. Many of the respondents believe the FAA Academy AF Division should be straight-lined to the AFZ organization in Headquarters. Most of the respondents still see the FAA organization as a closed-type structure with a top-down management style. Another important outcome of the findings was many of the respondents believed, regardless of the structure, employees should be empowered more and allowed to participate in the decision-making process. Based on the findings some of the advantages of straight-lined organizations were: it brings the parent organization in and gives them a first hand view of its operations, there is no middle person involved, and there is a direct line to parent organization. The disadvantages of straight-lined organizations based on the findings were: there is no middle management to speak to headquarters as an intermediator on training issues/concerns, it requires more resources and funding that may not be forthcoming, and it compels a parent organization to acquire more resources to handle its own business.

  3. CCD[charge-coupled device]-based synchrotron x-ray detector for protein crystallography: Performance projected from an experiment

    International Nuclear Information System (INIS)

    Strauss, M.G.; Naday, I.; Sherman, I.S.; Kraimer, M.R.; Westbrook, E.M.

    1986-01-01

    The intense x radiation from a synchrotron source could, with a suitable detector, provide a complete set of diffraction images from a protein crystal before the crystal is damaged by radiation (2 to 3 min). An area detector consisting of a 40 mm dia. x-ray fluorescing phosphor, coupled with an image intensifier and lens to a CCD image sensor, was developed to determine the effectiveness of such a detector in protein crystallography. The detector was used in an experiment with a rotating anode x-ray generator. Diffraction patterns from a lysozyme crystal obtained with this detector are compared to those obtained with film. The two images appear to be virtually identical. The flux of 10 4 x-ray photons/s was observed on the detector at the rotating anode generator. At the 6-GeV synchrotron being designed at Argonne, the flux on an 80 x 80 mm 2 detector is expected to be >10 9 photons/s. The projected design of such a synchrotron detector shows that a diffraction-peak count >10 6 could be obtained in ∼0.5 s. With an additional ∼0.5 s readout time of a 512 x 512 pixel CCD, the data acquisition time per frame would be ∼1 s so that ninety 1 0 diffraction images could be obtained, with approximately 1% precision, in less than 3 min

  4. Methods of X-ray examination of condylar knee replacement

    International Nuclear Information System (INIS)

    Vavrik, P.

    1988-01-01

    A detailed description is presented of the methodology of X-ray examination of patients with a condylar knee replacement. Preoperative examination includes standard anterio-posterior and lateral projections, axial projection of the patella in 30 deg flexion of the knee, examination of the mechanical axis of the extremity on a 90 x 30 format and the radioscopic assessment of the centre of the hip joint, essential for the correct centering of the knee implant. Immediately after surgery the position of the implant is checked in two standard projections. Another X-ray check is made after six weeks, before partial loading of the joint is permitted. A complete X-ray examination is made prior to the full loading of the knee joint. The methods are also discussed of the X-ray evaluation of complications such as aseptic loosening of the components, infection, instability, fractures. The general solution od these problems is described. The necessity is underlined of the deliberate and qualified indication of X-ray examinations. The basic prerequisites are listed for reducing the present considerable radiation burden of these patients in the course of the many X-ray examinations. (author). 7 figs., 3 tab., 6 refs

  5. Thermal, infrared and X-ray studies on praseodymium and neodymium myristates

    International Nuclear Information System (INIS)

    Upadhyaya, S.K.; Sharma, P.S.

    1993-01-01

    The thermal decomposition of praseodymium and neodymium myristates has been studied both as a function of temperature and of time. The thermogravimetric analysis has shown that order of decomposition reaction is kinetically of zero order and the energy of activation for the decomposition process lies in the range of 10-15 kcal mol -1 . The IR results showed that lanthanide myristates have an ionic character. The X-ray analysis indicated that the zigzag chains of the fatty acid radical constituent of the soap molecules extend straight forward on both sides of each basal plane and the molecular axes of the soap molecules are somewhat inclined to the basal plane. (author). 5 refs., 2 tabs

  6. Even the Best Have Difficulties: A Study of Finnish Straight-A Graduates' Resource-Oriented Solutions

    Science.gov (United States)

    Salmela, Mari; Määttä, Kaarina

    2015-01-01

    To achieve top scores, students need not only talents and study skills but also they have to conquer various adversities successfully. This research focused on the study paths, the concept adopted from Hickman, Bartholomew, Mathwig, and Heinrich (2008), of Finnish straight-A graduates in general upper secondary education. In this article, we refer…

  7. Offsetting Risks: High School Gay-Straight Alliances and Lesbian, Gay, Bisexual, and Transgender (LGBT) Youth

    Science.gov (United States)

    Heck, Nicholas C.; Flentje, Annesa; Cochran, Bryan N.

    2011-01-01

    Lesbian, gay, bisexual, and transgender (LGBT) youth are at risk for engaging in negative health behaviors and for experiencing at-school victimization. Specific benefits of attending a high school with a gay-straight alliance (GSA), including lower levels of suicidality, have been published; however, it is unclear whether GSAs are related to…

  8. X-Ray Polarimetry with GEMS

    Science.gov (United States)

    Strohmayer, Tod

    2011-01-01

    The polarization properties of cosmic X-ray sources are still largely unexplored. The Gravity and Extreme Magnetism SMEX (GEMS) will carry out the first sensitive X-ray polarization survey of a wide range of sources including; accreting compact objects (black holes and neutron stars), AGN, supernova remnants, magnetars and rotation-powered pulsars. GEMS employs grazing-incidence foil mirrors and novel time-projection chamber (TPC) polarimeters leveraging the photoelectric effect to achieve high polarization sensitivity in the 2 - 10 keV band. I will provide an update of the project status, illustrate the expected performance with several science examples, and provide a brief overview of the data analysis challenges

  9. The EEE Project status and perspectives

    CERN Document Server

    Antolini, R; Baldini Ferroli, R; Bencivenni, G; Blanco, F; Bressan, E; Chiavassa, A; Cifarelli, L; Cindolo, F; Coccia, E; De Pasquale, S; Di Giovanni, A; D'Incecco, M; Fabbri, F L; Garbini, M; Gustavino, C; Hatzifotiadou, D; Imponente, G; La Rocca, P; Librizzi, F; Menghetti, H; Miozzi, S; Pappalardo,G S; Piragino, G; Riggi, F; Sartorelli, G; Sbarra, C; Selvi, M; Williams, C; Zichichi, A

    2007-01-01

    The Extreme Energy Events (EEE) project plans to build and use an array of cosmic ray telescopes for muon detection, distributed over the italian territory. The use of such telescopes, based on Multigap Resistive Plate Chambers (MRPC) will allow the study of cosmic ray showers and the correlation between multiple primaries producing distant showers. The project is also intended to involve high school teams in an advanced research work. The physics items which can be addressed by such array, and the present status and perspectives of the project are here discussed.

  10. Status of the GILDA project for the 30 MeV-100 GeV high energy gamma ray astrophysics

    Energy Technology Data Exchange (ETDEWEB)

    Casolino, M.; Sparvoli, R.; Morselli, A.; Picozza, P. [Rome Univ. `Tor Vergata` (Italy)]|[INFN, Rome (Italy); Barbiellini, G. [Trieste Univ. (Italy)]|[INFN, Trieste (Italy); Fuglesang, C. [ESA-EAC, Cologne (Germany); Ozerov, Yu.V.; Zemskov, V.M.; Zverev, V.G.; Galper, A.M. [Moscow Engineering Physics Institute, Moscow (Russian Federation)

    1995-09-01

    High energy gamma-ray astrophysics has greatly developed in the last few years because of the results of EGRET, on the Compton gamma ray observatory. The satellite observations have shown the importance of continuing the investigation of high energy gamma radiation but the emerging of new astrophysical and cosmological problems require for future experiments the realization of telescopes with parameters significatively improved with respect to the previous missions. In a traditional point of view, this is achieved with the increase of the length L of the device and, consequently, the mass of the telescope and satellite (growing as L{sup 3}). Such kinds of experiments are becoming rather expensive and are approaching the maximum value in cost, satellite mass and consuming resources. The telescope project GILDA presented in this paper is based on the use of silicon strip detectors. The silicon technique consents to obtain a much wider solid angle aperture; in this way there is more sensitivity without a growing in the size of the

  11. Status of the GILDA project for the 30 MeV-100 GeV high energy gamma ray astrophysics

    International Nuclear Information System (INIS)

    Casolino, M.; Sparvoli, R.; Morselli, A.; Picozza, P.; Barbiellini, G.; Fuglesang, C.; Ozerov, Yu.V.; Zemskov, V.M.; Zverev, V.G.; Galper, A.M.

    1995-01-01

    High energy gamma-ray astrophysics has greatly developed in the last few years because of the results of EGRET, on the Compton gamma ray observatory. The satellite observations have shown the importance of continuing the investigation of high energy gamma radiation but the emerging of new astrophysical and cosmological problems require for future experiments the realization of telescopes with parameters significatively improved with respect to the previous missions. In a traditional point of view, this is achieved with the increase of the length L of the device and, consequently, the mass of the telescope and satellite (growing as L 3 ). Such kinds of experiments are becoming rather expensive and are approaching the maximum value in cost, satellite mass and consuming resources. The telescope project GILDA presented in this paper is based on the use of silicon strip detectors. The silicon technique consents to obtain a much wider solid angle aperture; in this way there is more sensitivity without a growing in the size of the

  12. The GALAXIE all-optical FEL project

    Energy Technology Data Exchange (ETDEWEB)

    Rosenzweig, J. B.; Arab, E.; Andonian, G.; Cahill, A.; Fitzmorris, K.; Fukusawa, A.; Hoang, P.; Jovanovic, I.; Marcus, G.; Marinelli, A.; Murokh, A.; Musumeci, P.; Naranjo, B.; O' Shea, B.; O' Shea, F.; Ovodenko, A.; Pogorelsky, I.; Putterman, S.; Roberts, K.; Shumail, M. [Dept. of Physics and Astronomy, University of California, Los Angeles, 405 Hilgard Ave., Los Angeles, CA 90034 (United States); Dept. of Mechanical and Nuclear Engineering, Pennsylvania State University, University Park, PA 16802 (United States); Dept. of Physics and Astronomy, University of California, Los Angeles, 405 Hilgard Ave., Los Angeles, CA 90034 (United States); and others

    2012-12-21

    We describe a comprehensive project, funded under the DARPA AXiS program, to develop an all-optical table-top X-ray FEL based on dielectric acceleration and electromagnetic undulators, yielding a compact source of coherent X-rays for medical and related applications. The compactness of this source demands that high field (>GV/m) acceleration and undulation-inducing fields be employed, thus giving rise to the project's acronym: GV/m AcceLerator And X-ray Integrated Experiment (GALAXIE). There are numerous physics and technical hurdles to surmount in this ambitious scenario, and the integrated solutions include: a biharmonic photonic TW structure, 200 micron wavelength electromagnetic undulators, 5 {mu}m laser development, ultra-high brightness magnetized/asymmetric emittance electron beam generation, and SASE FEL operation. We describe the overall design philosophy of the project, the innovative approaches to addressing the challenges presented by the design, and the significant progress towards realization of these approaches in the nine months since project initialization.

  13. Forensic facial reconstruction: Nasal projection in Brazilian adults.

    Science.gov (United States)

    Tedeschi-Oliveira, Silvia Virginia; Beaini, Thiago Leite; Melani, Rodolfo Francisco Haltenhoff

    2016-09-01

    The nose has a marked cognitive influence on facial image; however, it loses its shape during cadaveric decomposition. The known methods of estimating nasal projection using Facial Reconstruction are lacking in practicality and reproducibility. We attempted to relate the points Rhinion, Pronasale and Prosthion by studying the angle formed by straight lines that connect them. Two examiners measured this angle with the help of analysis and image-processing software, Image J, directly from cephalometric radiographs. The sample consisted of 300 males, aged between 24 and 77 years, and 300 females, aged 24 to 69 years. The proposed angle ranged from 80° to 100° in both sexes and all ages. It was considered possible to use a 90° angle from projections of the Rhinion and Prosthion points in order to determine the Pronasale position, as well as to estimate the nasal projection of Brazilian adults. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. RAY-UI: A powerful and extensible user interface for RAY

    Energy Technology Data Exchange (ETDEWEB)

    Baumgärtel, P., E-mail: peter.baumgaertel@helmholtz-berlin.de; Erko, A.; Schäfers, F. [Institute for Nanometre Optics and Technology Helmholtz Zentrum Berlin für Materialien und Energie Albert-Einstein-Str. 15, 12489 Berlin (Germany); Witt, M. [Department Operation Accelerator BESSY II Helmholtz Zentrum Berlin für Materialien und Energie Albert-Einstein-Str. 15, 12489 Berlin (Germany); Baensch, J.; Fabarius, M.; Schirmacher, H. [Fachbereich VI – Informatik und Medien Beuth Hochschule für Technik Berlin, Luxemburger Str. 10, 13353 Berlin (Germany)

    2016-07-27

    The RAY-UI project started as a proof-of-concept for an interactive and graphical user interface (UI) for the well-known ray tracing software RAY [1]. In the meantime, it has evolved into a powerful enhanced version of RAY that will serve as the platform for future development and improvement of associated tools. The software as of today supports nearly all sophisticated simulation features of RAY. Furthermore, it delivers very significant usability and work efficiency improvements. Beamline elements can be quickly added or removed in the interactive sequence view. Parameters of any selected element can be accessed directly and in arbitrary order. With a single click, parameter changes can be tested and new simulation results can be obtained. All analysis results can be explored interactively right after ray tracing by means of powerful integrated image viewing and graphing tools. Unlimited image planes can be positioned anywhere in the beamline, and bundles of image planes can be created for moving the plane along the beam to identify the focus position with live updates of the simulated results. In addition to showing the features and workflow of RAY-UI, we will give an overview of the underlying software architecture as well as examples for use and an outlook for future developments.

  15. Application of a drift-flux model to flashing in straight pipes

    International Nuclear Information System (INIS)

    Hirt, C.W.; Romero, N.C.

    1975-06-01

    A new computer program, SOLA-OF, has been written to solve the unsteady, two-dimensional equations of motion for a two-phase mixture. The equations solved are based on the drift-flux approximation and include a phase transition model and a general drift velocity calculation. The SOLA-DF code is used for a study of the blowdown of straight pipes initially filled with water at high temperature and pressure. Computed results are presented that show the relative importance of phase transition rates, pipe friction, drift velocity magnitude, and other model variations. The computed results are also compared with experimental data. 7 references. (auth)

  16. Context based Coding of Binary Shapes by Object Boundary Straightness Analysis

    DEFF Research Database (Denmark)

    Aghito, Shankar Manuel; Forchhammer, Søren

    2004-01-01

    A new lossless compression scheme for bilevel images targeted at binary shapes of image and video objects is presented. The scheme is based on a local analysis of the digital straightness of the causal part of the object boundary, which is used in the context definition for arithmetic encoding....... Tested on individual images of binary shapes and binary layers of digital maps the algorithm outperforms PWC, JBIG and MPEG-4 CAE. On the binary shapes the code lengths are reduced by 21%, 25%, and 42%, respectively. On the maps the reductions are 34%, 32%, and 59%, respectively. The algorithm is also...

  17. Department of Cosmic Ray Physics; Overview

    International Nuclear Information System (INIS)

    Szabelski, J.

    2003-01-01

    project of large air shower array for studies of cosmic rays up to 1020 eV. Detectors would be placed on the roofs of high schools in Lodz. Using the urban infrastructure (INTERNET, electricity etc.) we can significantly lower the cost of the experiment. The educational effects of the project are very important. The response to the project from the local authorities, school teachers and students was very good. (author)

  18. Department of Cosmic Ray Physics: Overview

    International Nuclear Information System (INIS)

    Szabelski, J.

    2002-01-01

    Full text:The Department of Cosmic Ray Physics in Lodz is involved in basic research in the area of high-energy physics and cosmic ray physics related to: * Experimental and phenomenological studies of Extensive Air Showers induced by cosmic ray particles. * Studies of ultra-high energy (above 10 19 eV) cosmic rays: determination of energy spectrum and mass composition of primary particles * Studies of asymptotic properties of hadronic interactions based on the analysis of cosmic ray propagation through the atmosphere. * Studies of mass composition of cosmic rays in the energy range 10 15 -10 17 eV. * Registration of cosmic ray intensity variation correlated with solar activity. Theoretical and experimental studies of Extensive Air Shower properties are performed mostly based on the results obtained by the Lodz Extensive Air Shower Array. We have noticed unexplainable delayed signals registered about 500-900 microseconds after the main EAS pulse. We prepared hardware for further experimental study of this effect. Continuous registrations of 5 GeV muon flux with the underground muon telescope have been carried on during 2001. We detected several changes of muon intensity correlated with Forbush decreases registered at lower energies. We have also started registration of the muon counting rate in on-surface scintillation detectors. These measurements will be included to the analysis of the disturbed energy spectrum of primary cosmic rays and its dependence on interplanetary disturbances related to solar activity. In construction and data interpretation of cosmic ray experiments the Lodz group collaborates with many foreign institutes and laboratories: Forschungszentrum in Karlsruhe (Germany), College de France, Institute for Nuclear Studies of the Russian Academy of Sciences, Uppsala University (Sweden) and DESY (Germany). We have prepared a project of large air shower array for studies of cosmic rays up to 10 20 eV. Detectors would be placed on the roofs of high

  19. Real-time volumetric image reconstruction and 3D tumor localization based on a single x-ray projection image for lung cancer radiotherapy.

    Science.gov (United States)

    Li, Ruijiang; Jia, Xun; Lewis, John H; Gu, Xuejun; Folkerts, Michael; Men, Chunhua; Jiang, Steve B

    2010-06-01

    To develop an algorithm for real-time volumetric image reconstruction and 3D tumor localization based on a single x-ray projection image for lung cancer radiotherapy. Given a set of volumetric images of a patient at N breathing phases as the training data, deformable image registration was performed between a reference phase and the other N-1 phases, resulting in N-1 deformation vector fields (DVFs). These DVFs can be represented efficiently by a few eigenvectors and coefficients obtained from principal component analysis (PCA). By varying the PCA coefficients, new DVFs can be generated, which, when applied on the reference image, lead to new volumetric images. A volumetric image can then be reconstructed from a single projection image by optimizing the PCA coefficients such that its computed projection matches the measured one. The 3D location of the tumor can be derived by applying the inverted DVF on its position in the reference image. The algorithm was implemented on graphics processing units (GPUs) to achieve real-time efficiency. The training data were generated using a realistic and dynamic mathematical phantom with ten breathing phases. The testing data were 360 cone beam projections corresponding to one gantry rotation, simulated using the same phantom with a 50% increase in breathing amplitude. The average relative image intensity error of the reconstructed volumetric images is 6.9% +/- 2.4%. The average 3D tumor localization error is 0.8 +/- 0.5 mm. On an NVIDIA Tesla C1060 GPU card, the average computation time for reconstructing a volumetric image from each projection is 0.24 s (range: 0.17 and 0.35 s). The authors have shown the feasibility of reconstructing volumetric images and localizing tumor positions in 3D in near real-time from a single x-ray image.

  20. Simplified methods for estimating gamma exposure fields transmitted through straight rectangular ducts

    International Nuclear Information System (INIS)

    Shultis, J.K.; Thompson, K.R.; Faw, R.E.

    1986-01-01

    Approximate computational models are developed to describe the spatial variation in the radiation field transmitted through a straight reactangular duct obliquely illuminated by monoenergetic gamma photons. These models account for single and multiple scattering from the duct walls and lips as well as for direct penetration by the photons. Results of calculations are compared to results from a recent benchmark duct streaming experiment, and empirical correction factors are obtained which enable the models to predict the transmitted exposure rates to within 20% of the experimental values

  1. Rapid simulation of X-ray transmission imaging for baggage inspection via GPU-based ray-tracing

    Science.gov (United States)

    Gong, Qian; Stoian, Razvan-Ionut; Coccarelli, David S.; Greenberg, Joel A.; Vera, Esteban; Gehm, Michael E.

    2018-01-01

    We present a pipeline that rapidly simulates X-ray transmission imaging for arbitrary system architectures using GPU-based ray-tracing techniques. The purpose of the pipeline is to enable statistical analysis of threat detection in the context of airline baggage inspection. As a faster alternative to Monte Carlo methods, we adopt a deterministic approach for simulating photoelectric absorption-based imaging. The highly-optimized NVIDIA OptiX API is used to implement ray-tracing, greatly speeding code execution. In addition, we implement the first hierarchical representation structure to determine the interaction path length of rays traversing heterogeneous media described by layered polygons. The accuracy of the pipeline has been validated by comparing simulated data with experimental data collected using a heterogenous phantom and a laboratory X-ray imaging system. On a single computer, our approach allows us to generate over 400 2D transmission projections (125 × 125 pixels per frame) per hour for a bag packed with hundreds of everyday objects. By implementing our approach on cloud-based GPU computing platforms, we find that the same 2D projections of approximately 3.9 million bags can be obtained in a single day using 400 GPU instances, at a cost of only 0.001 per bag.

  2. Effects of ray profile modeling on resolution recovery in clinical CT

    International Nuclear Information System (INIS)

    Hofmann, Christian; Knaup, Michael; Kachelrieß, Marc

    2014-01-01

    Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. However, among vendors and researchers, there is no consensus of how to best achieve these goals. The authors are focusing on the aspect of geometric ray profile modeling, which is realized by some algorithms, while others model the ray as a straight line. The authors incorporate ray-modeling (RM) in nonregularized iterative reconstruction. That means, instead of using one simple single needle beam to represent the x-ray, the authors evaluate the double integral of attenuation path length over the finite source distribution and the finite detector element size in the numerical forward projection. Our investigations aim at analyzing the resolution recovery (RR) effects of RM. Resolution recovery means that frequencies can be recovered beyond the resolution limit of the imaging system. In order to evaluate, whether clinical CT images can benefit from modeling the geometrical properties of each x-ray, the authors performed a 2D simulation study of a clinical CT fan-beam geometry that includes the precise modeling of these geometrical properties. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and a Forbild thorax phantom with circular resolution patterns representing calcifications in the heart region are simulated. An FBP reconstruction with a Ram–Lak kernel is used as a reference reconstruction. The FBP is compared to iterative reconstruction techniques with and without RM: An ordered subsets convex (OSC) algorithm without any RM (OSC), an OSC where the forward projection is modeled concerning the finite focal spot and detector size (OSC-RM) and an OSC with RM and with a matched forward and backprojection pair (OSC-T-RM, T for transpose). In all cases, noise was matched to

  3. Statistical analysis of x-ray stress measurement by centroid method

    International Nuclear Information System (INIS)

    Kurita, Masanori; Amano, Jun; Sakamoto, Isao

    1982-01-01

    The X-ray technique allows a nondestructive and rapid measurement of residual stresses in metallic materials. The centroid method has an advantage over other X-ray methods in that it can determine the angular position of a diffraction line, from which the stress is calculated, even with an asymmetrical line profile. An equation for the standard deviation of the angular position of a diffraction line, σsub(p), caused by statistical fluctuation was derived, which is a fundamental source of scatter in X-ray stress measurements. This equation shows that an increase of X-ray counts by a factor of k results in a decrease of σsub(p) by a factor of 1/√k. It also shows that σsub(p) increases rapidly as the angular range used in calculating the centroid increases. It is therefore important to calculate the centroid using the narrow angular range between the two ends of the diffraction line where it starts to deviate from the straight background line. By using quenched structural steels JIS S35C and S45C, the residual stresses and their standard deviations were calculated by the centroid, parabola, Gaussian curve, and half-width methods, and the results were compared. The centroid of a diffraction line was affected greatly by the background line used. The standard deviation of the stress measured by the centroid method was found to be the largest among the four methods. (author)

  4. Extension of Ko Straight-Beam Displacement Theory to Deformed Shape Predictions of Slender Curved Structures

    Science.gov (United States)

    Ko, William L.; Fleischer, Van Tran

    2011-01-01

    The Ko displacement theory originally developed for shape predictions of straight beams is extended to shape predictions of curved beams. The surface strains needed for shape predictions were analytically generated from finite-element nodal stress outputs. With the aid of finite-element displacement outputs, mathematical functional forms for curvature-effect correction terms are established and incorporated into straight-beam deflection equations for shape predictions of both cantilever and two-point supported curved beams. The newly established deflection equations for cantilever curved beams could provide quite accurate shape predictions for different cantilever curved beams, including the quarter-circle cantilever beam. Furthermore, the newly formulated deflection equations for two-point supported curved beams could provide accurate shape predictions for a range of two-point supported curved beams, including the full-circular ring. Accuracy of the newly developed curved-beam deflection equations is validated through shape prediction analysis of curved beams embedded in the windward shallow spherical shell of a generic crew exploration vehicle. A single-point collocation method for optimization of shape predictions is discussed in detail

  5. A Closed-Form Error Model of Straight Lines for Improved Data Association and Sensor Fusing

    Directory of Open Access Journals (Sweden)

    Volker Sommer

    2018-04-01

    Full Text Available Linear regression is a basic tool in mobile robotics, since it enables accurate estimation of straight lines from range-bearing scans or in digital images, which is a prerequisite for reliable data association and sensor fusing in the context of feature-based SLAM. This paper discusses, extends and compares existing algorithms for line fitting applicable also in the case of strong covariances between the coordinates at each single data point, which must not be neglected if range-bearing sensors are used. Besides, in particular, the determination of the covariance matrix is considered, which is required for stochastic modeling. The main contribution is a new error model of straight lines in closed form for calculating quickly and reliably the covariance matrix dependent on just a few comprehensible and easily-obtainable parameters. The model can be applied widely in any case when a line is fitted from a number of distinct points also without a priori knowledge of the specific measurement noise. By means of extensive simulations, the performance and robustness of the new model in comparison to existing approaches is shown.

  6. 3D-shape of objects with straight line-motion by simultaneous projection of color coded patterns

    Science.gov (United States)

    Flores, Jorge L.; Ayubi, Gaston A.; Di Martino, J. Matías; Castillo, Oscar E.; Ferrari, Jose A.

    2018-05-01

    In this work, we propose a novel technique to retrieve the 3D shape of dynamic objects by the simultaneous projection of a fringe pattern and a homogeneous light pattern which are both coded in two of the color channels of a RGB image. The fringe pattern, red channel, is used to retrieve the phase by phase-shift algorithms with arbitrary phase-step, while the homogeneous pattern, blue channel, is used to match pixels from the test object in consecutive images, which are acquired at different positions, and thus, to determine the speed of the object. The proposed method successfully overcomes the standard requirement of projecting fringes of two different frequencies; one frequency to extract object information and the other one to retrieve the phase. Validation experiments are presented.

  7. Youth empowerment and high school Gay-Straight Alliances.

    Science.gov (United States)

    Russell, Stephen T; Muraco, Anna; Subramaniam, Aarti; Laub, Carolyn

    2009-08-01

    In the field of positive youth development programs, "empowerment" is used interchangeably with youth activism, leadership, civic participation and self-efficacy. However, few studies have captured what empowerment means to young people in diverse contexts. This article explores how youth define and experience empowerment in youth-led organizations characterized by social justice goals: high school Gay-Straight Alliances (GSAs). Through focus group interviews, fifteen youth leaders of GSAs from different regions of California explain what they think empowerment means and how they became empowered through their involvement with the GSA. Youth describe three inter-related dimensions of empowerment: personal empowerment, relational empowerment, and strategic empowerment through having and using knowledge. When these three dimensions are experienced in combination, GSA leaders have the potential for individual and collective empowerment as agents of social change at school. By understanding these youth's perspectives on the meanings of empowerment, this article clarifies the conceptual arena for future studies of socially marginalized youth and of positive youth development.

  8. Youth Empowerment and High School Gay-Straight Alliances

    Science.gov (United States)

    Muraco, Anna; Subramaniam, Aarti; Laub, Carolyn

    2010-01-01

    In the field of positive youth development programs, “empowerment” is used interchangeably with youth activism, leadership, civic participation and self-efficacy. However, few studies have captured what empowerment means to young people in diverse contexts. This article explores how youth define and experience empowerment in youth-led organizations characterized by social justice goals: high school Gay-Straight Alliances (GSAs). Through focus group interviews, fifteen youth leaders of GSAs from different regions of California explain what they think empowerment means and how they became empowered through their involvement with the GSA. Youth describe three inter-related dimensions of empowerment: personal empowerment, relational empowerment, and strategic empowerment through having and using knowledge. When these three dimensions are experienced in combination, GSA leaders have the potential for individual and collective empowerment as agents of social change at school. By understanding these youth's perspectives on the meanings of empowerment, this article clarifies the conceptual arena for future studies of socially marginalized youth and of positive youth development. PMID:19636734

  9. WE-G-207-02: Full Sequential Projection Onto Convex Sets (FS-POCS) for X-Ray CT Reconstruction

    International Nuclear Information System (INIS)

    Liu, L; Han, Y; Jin, M

    2015-01-01

    Purpose: To develop an iterative reconstruction method for X-ray CT, in which the reconstruction can quickly converge to the desired solution with much reduced projection views. Methods: The reconstruction is formulated as a convex feasibility problem, i.e. the solution is an intersection of three convex sets: 1) data fidelity (DF) set – the L2 norm of the difference of observed projections and those from the reconstructed image is no greater than an error bound; 2) non-negativity of image voxels (NN) set; and 3) piecewise constant (PC) set - the total variation (TV) of the reconstructed image is no greater than an upper bound. The solution can be found by applying projection onto convex sets (POCS) sequentially for these three convex sets. Specifically, the algebraic reconstruction technique and setting negative voxels as zero are used for projection onto the DF and NN sets, respectively, while the projection onto the PC set is achieved by solving a standard Rudin, Osher, and Fatemi (ROF) model. The proposed method is named as full sequential POCS (FS-POCS), which is tested using the Shepp-Logan phantom and the Catphan600 phantom and compared with two similar algorithms, TV-POCS and CP-TV. Results: Using the Shepp-Logan phantom, the root mean square error (RMSE) of reconstructed images changing along with the number of iterations is used as the convergence measurement. In general, FS- POCS converges faster than TV-POCS and CP-TV, especially with fewer projection views. FS-POCS can also achieve accurate reconstruction of cone-beam CT of the Catphan600 phantom using only 54 views, comparable to that of FDK using 364 views. Conclusion: We developed an efficient iterative reconstruction for sparse-view CT using full sequential POCS. The simulation and physical phantom data demonstrated the computational efficiency and effectiveness of FS-POCS

  10. X ray reflection masks: Manufacturing, characterization and first tests

    Science.gov (United States)

    Rahn, Stephen

    1992-09-01

    SXPL (Soft X-ray Projection Lithography) multilayer mirrors are characterized, laterally structured and then used as reflection masks in a projecting lithography procedure. Mo/Si-multilayer mirrors with a 2d in the region of 14 nm were characterized by Cu-k(alpha) grazing incidence as well as soft X-ray normal incidence reflectivity measurements. The multilayer mirrors were patterned by reactive ion etching with CF4 using a photoresist as etch mask, thus producing X-ray reflection masks. The masks were tested at the synchrotron radiation laboratory of the electron accelerator ELSA. A double crystal X-ray monochromator was modified so as to allow about 0.5 sq cm of the reflection mask to be illuminated by white synchrotron radiation. The reflected patterns were projected (with an energy of 100 eV) onto a resist and structure sizes down to 8 micrometers were nicely reproduced. Smaller structures were distorted by Fresnel-diffraction. The theoretically calculated diffraction images agree very well with the observed images.

  11. The PASERO Project: parallel and serial readout systems for gas proportional synchrotron radiation X-ray detectors

    CERN Document Server

    Koch, M H J; Briquet-Laugier, F; Epstein, A; Sheldon, S; Beloeuvre, E; Gabriel, A; Hervé, C; Kocsis, M; Koschuch, A; Laggner, P; Leingartner, W; Raad-Iseli, C D; Reimann, T; Golding, F; Torki, K

    2001-01-01

    A project aiming at producing more efficient position sensitive gas proportional detectors and readout systems is presented. An area detector with reduced electrode spacing and a spatial resolution of 0.5 mm and two time to digital convertors (TDC) based on ASICs were produced. The first TDC, intended for use with linear detectors, relies on time to space conversion, whereas the second one, for area detectors, uses a ring oscillator with a phase locked loop. A parallel readout system for multi-anode detectors aiming at a maximum count rate extensively uses RISC microcontrollers. An electronic simulator of linear detectors built for test purposes and a mechanical chopper used for attenuation of the X-ray beam are also briefly described.

  12. 50 CFR Figures 14a and 14b to Part... - Maximum Angle of Deflector Bars With Straight Bars Attached to the Bottom of the Frame and...

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Maximum Angle of Deflector Bars With Straight Bars Attached to the Bottom of the Frame and Maximum Angle of Deflector Bars With Bent Bars... 223—Maximum Angle of Deflector Bars With Straight Bars Attached to the Bottom of the Frame and Maximum...

  13. Possibility of whole-surface analysis of a silicon wafer with ordinary straight TXRF

    International Nuclear Information System (INIS)

    Mori, Y.; Uemura, K.; Iizuka, Y.

    2000-01-01

    For the analysis of average metal concentration on a semiconductor surface, we customarily use the wet techniques (AAS, typically), that require skilled operators or expensive automated machines for sample pretreatment. The straight TXRF require no pretreatment, on the other hand. However, its detection area is too small (1-2 cm 2 ) to conduct a whole-surface analysis. In fact, it takes more than one day per one wafer (500 s/point x 100-300 points) for a complete mapping. Therefore it has been believed that the whole-surface analysis with straight TXRF is impracticable. It should be noted that the absolute lower limit of detection (LLD) of the straight TXRF is superior to AAS. As an example, the absolute LLD of TXRF for Fe is 0.2 pg (500 s integration), while that of AAS is l0 pg. The required integration time for TXRF to obtain the same LLD of AAS is calculated to be only 0.2 s. This means, in principle, that the whole-surface contamination can be measured in some ten seconds by accumulating 0.2 s mapping. But actually, the adjustment of glancing angle requires several ten seconds per one point, so the above mapping still takes several hours. That is why such a measurement has not been applied to daily analysis so far. However, the influence of glancing angle errors is expected to be reduced through the multi-point measurement. Figure 1 shows an accumulated spectrum of 20 s x 25 points mapping for an IAP wafer doped with Ni. In this measurement, glancing angles were not precisely controlled (the error of glancing angle is ±15 %). A spectrum of 500 s x 1 point measurement for the same wafer is shown in Figure 2. Figures 1 and 2 are almost identical. This suggests that the reduction of glancing angle errors actually works well through multi-points measurement. This method is expected to give better results by increasing the number of measuring points. The overall variation for the final measurement value obtained by multi-point measurement can be assessed by the

  14. Gay-Straight Alliances in the Battle for Rights: A Tipping Point for Progress over Prohibition

    Science.gov (United States)

    Sinclair, James; Reece, Brian J.

    2016-01-01

    This is a brief essay on the oppressive natures of school and the rights of students to arm themselves with the creation of Gay-Straight Alliances (GSAs). Students who identify as LGBTQ are at higher risk for victimization, among other negative outcomes. For those who identify as LGBTQ, GSAs are often a safe-haven from the heteronormative…

  15. Characterization of Metalloproteins and Biomaterials by X-ray Absorption Spectroscopy and X-ray Diffraction

    DEFF Research Database (Denmark)

    Frankær, Christian Grundahl

    This thesis presents thework on combining complementary X-rays techniques for studying the structures of proteins and other biomaterials, and consists of three different projects: (i) Characterization of protein powders with X-ray powder diffraction (XRPD). (ii) The combination of X-ray...... crystallography and X-ray absorption spectroscopy (XAS) applied to studying different hexameric insulin conformations. (iii) The structures of polymorphs of strontium ranelate and the distribution of strontium in bone tissue. A procedure for fast identification and verification of protein powders using XRPD...... was correction for disordered bulk-solvent, but also correction for background and optimization of unit cell parameters have to be taken into account. A sample holder was designed for collecting powder diffraction data on a standard laboratory X-ray powder diffractometer. The background was reduced by use...

  16. Contextualizing Gay-straight Alliances: Student, Advisor, and Structural Factors Related to Positive Youth Development among Members

    Science.gov (United States)

    Poteat, V. Paul; Yoshikawa, Hirokazu; Calzo, Jerel P.; Gray, Mary L.; DiGiovanni, Craig D.; Lipkin, Arthur; Mundy-Shephard, Adrienne; Perrotti, Jeff; Scheer, Jillian R.; Shaw, Matthew P.

    2015-01-01

    Gay-straight alliances (GSAs) may promote resilience. Yet, what GSA components predict well-being? Among 146 youth and advisors in 13 GSAs (58% lesbian, gay, bisexual, or questioning; 64% White; 38% received free/reduced-cost lunch), student (demographics, victimization, attendance frequency, leadership, support, control), advisor (years served,…

  17. Impact of a Vertically Polarized Undulator on LCLS Hard X-ray Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, David [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2014-11-14

    The LCLS-II project will install two variable gap, horizontally polarized undulators into the LCLS undulator hall. One undulator is designed to produce soft x-rays spanning an energy range of 200-1250 eV (SXU) while the other is designed for the hard spectral range of 1-25 keV (HXU). The hard x-ray LCLS instruments (X-ray Pump- Probe [XPP], X-ray correlation Spectroscopy [XCS], Coherent X-ray Imaging [CXI], Matter in Extreme Conditions [MEC]) will be repurposed to operate on the HXU line while two new soft x-ray beamlines will be created for the SXU line. An alternate HXU undulator design is being considered that could provide advantages over the present design choice. In particular, the project team is collaborating with Argonne National Laboratory to develop a vertically polarized undulator (VPU). A 1-m prototype VPU device was successfully constructed this year and a full size prototype is in process. A decision to alter the project baseline, which is the construction of a horizontally polarized device, must be made in the coming weeks to not impact the present project schedule. Please note that a change to the soft x-ray undulator is not under discussion at the moment.

  18. Use of spectral gamma ray as a lithology guide for fault rocks: A case study from the Wenchuan Earthquake Fault Scientific Drilling project Borehole 4 (WFSD-4).

    Science.gov (United States)

    Amara Konaté, Ahmed; Pan, Heping; Ma, Huolin; Qin, Zhen; Guo, Bo; Yevenyo Ziggah, Yao; Kounga, Claude Ernest Moussounda; Khan, Nasir; Tounkara, Fodé

    2017-10-01

    The main purpose of the Wenchuan Earthquake Fault Scientific drilling project (WFSD) was to produce an in-depth borehole into the Yingxiu-Beichuan (YBF) and Anxian-Guanxian faults in order to gain a much better understanding of the physical and chemical properties as well as the mechanical faulting involved. Five boreholes, namely WFSD-1, WFSD-2, WFSD-3P, WFSD-3 and WFSD-4, were drilled during the project entirety. This study, therefore, presents first-hand WFSD-4 data on the lithology (original rocks) and fault rocks that have been obtained from the WFSD project. In an attempt to determine the physical properties and the clay minerals of the lithology and fault rocks, this study analyzed the spectral gamma ray logs (Total gamma ray, Potassium, Thorium and Uranium) recorded in WFSD-4 borehole on the Northern segment of the YBF. The obtained results are presented as cross-plots and statistical multi log analysis. Both lithology and fault rocks show a variability of spectral gamma ray (SGR) logs responses and clay minerals. This study has shown the capabilities of the SGR logs for well-logging of earthquake faults and proves that SGR logs together with others logs in combination with drill hole core description is a useful method of lithology and fault rocks characterization. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Experimental evaluation of J in cracked straight and curved pipes under bending

    International Nuclear Information System (INIS)

    Moulin, D.; Touboul, F.; Foucher, N.; Lebey, J.; Acker, D.

    1989-01-01

    An experimental program is being carried out at the CEA Saclay in collaboration with FRAMATOME and IPSN with a view to validate analysis methods applicable for evaluation of leak before break behavior in P.W.R. piping. A large experimental work was already performed in USA, Germany and Japan and cracked pipes made of stainless steel material under bending. The methods of analysis got same validations for straight pipes. However applicability to elbows and comparison with toughness values obtained on small specimens like CT specimens was not completely dealt with

  20. Process for the selective cracking of straight-chained and slightly branched hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Gorring, R L; Shipman, G F

    1975-01-23

    The invention describes a method for the selective (hydro) cracking of petroleum materials, containing normal straight-chained and/or slightly branched-chained hydrocarbons. The mixture is brought into contact with a selective, crystalline alumino silicate zeolite cracking catalyst housing a silicon oxide/aluminum oxide ratio of at least about 12 and a constraint index of about 1 to 12 under cracking conditions. A zeolite catalyst with a crystal size of up to 0.05 ..mu.. is used. Solidification point and viscosity in particular of oils are to be lowered through the catalytic dewaxing.