WorldWideScience

Sample records for storm sewers

  1. 40 CFR 35.925-21 - Storm sewers.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Storm sewers. 35.925-21 Section 35.925... STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works-Clean Water Act § 35.925-21 Storm... treatment works for control of pollutant discharges from a separate storm sewer system (as defined in § 35...

  2. Real Rainfall Time Series for Storm Sewer Design

    DEFF Research Database (Denmark)

    Larsen, Torben

    The paper describes a simulation method for the design of retention storages, overflows etc. in storm sewer systems. The method is based on computer simulation with real rainfall time series as input ans with the aply of a simple transfer model of the ARMA-type (autoregressiv moving average model......) as the model of the storm sewer system. The output of the simulation is the frequency distribution of the peak flow, overflow volume etc. from the overflow or retention storage. The parameters in the transfer model is found either from rainfall/runoff measurements in the catchment or from one or a few...

  3. Searching for storm water inflows in foul sewers using fibre-optic distributed temperature sensing

    NARCIS (Netherlands)

    Schilperoort, R.; Hoppe, H.; Haan, C.; Langeveld, J.G.

    2012-01-01

    A major drawback of separate sewer systems is the occurrence of illicit connections: unintended sewer cross-connections that connect foul water outlets from residential or industrial premises to the storm water system and/or storm water outlets to the foul sewer system. The amount of unwanted storm

  4. Real Rainfall Time Series for Storm Sewer Design

    DEFF Research Database (Denmark)

    Larsen, Torben

    1981-01-01

    to a storm sewer system. The output of the simulation is the frequency distribution of the peak flow, overflow volume etc. from the overflow or the retention storage. The parameters in the transfer model are found either from rainfall/runoff measurements in the catchment or from one or more simulations...

  5. COMBINED AND STORM SEWER NETWORK MONITORING

    Directory of Open Access Journals (Sweden)

    Justyna Synowiecka

    2014-10-01

    Full Text Available Monitoring of the drainage networks is an extremely important tool used to understand the phenomena occurring in them. In an era of urbanization and increased run-off, at the expense of natural retention in the catchment, it helps to minimize the risk of local flooding and pollution. In its scope includes measurement of the amount of rainfall, with the use of rain gauges, and their measure in the sewer network, in matter of flows and channel filling, with the help of flow meters. An indispensable part in this step is their proper calibration calibration. In addition to ongoing monitoring of the sewer system, periodic inspections by the qualified employees of Water and Sewage Company should be done. The following article reviews measurement devices, their calibration methods, as well as the phenomena that occur during operation in the sewer network. It provides a solution for monitoring and control based on the experience of the Municipal Water and Sewage Company in Wroclaw, describing common operational problems, their causes, prevention methods and a network operation walkthrough with the improve of performance indicators KPI (Key Performance Indicators according the ECB (European Benchmarking Co-operation.

  6. COMBINED AND STORM SEWER NETWORK MONITORING

    OpenAIRE

    Justyna Synowiecka; Ewa Burszta-Adamiak; Tomasz Konieczny; Paweł Malinowski

    2014-01-01

    Monitoring of the drainage networks is an extremely important tool used to understand the phenomena occurring in them. In an era of urbanization and increased run-off, at the expense of natural retention in the catchment, it helps to minimize the risk of local flooding and pollution. In its scope includes measurement of the amount of rainfall, with the use of rain gauges, and their measure in the sewer network, in matter of flows and channel filling, with the help of flow meters. An indispens...

  7. Searching for storm water inflows in foul sewers using fibre-optic distributed temperature sensing.

    Science.gov (United States)

    Schilperoort, Rémy; Hoppe, Holger; de Haan, Cornelis; Langeveld, Jeroen

    2013-01-01

    A major drawback of separate sewer systems is the occurrence of illicit connections: unintended sewer cross-connections that connect foul water outlets from residential or industrial premises to the storm water system and/or storm water outlets to the foul sewer system. The amount of unwanted storm water in foul sewer systems can be significant, resulting in a number of detrimental effects on the performance of the wastewater system. Efficient removal of storm water inflows into foul sewers requires knowledge of the exact locations of the inflows. This paper presents the use of distributed temperature sensing (DTS) monitoring data to localize illicit storm water inflows into foul sewer systems. Data results from two monitoring campaigns in foul sewer systems in the Netherlands and Germany are presented. For both areas a number of storm water inflow locations can be derived from the data. Storm water inflow can only be detected as long as the temperature of this inflow differs from the in-sewer temperatures prior to the event. Also, the in-sewer propagation of storm and wastewater can be monitored, enabling a detailed view on advection.

  8. 78 FR 9908 - Notice of Availability of the Draft Issuance of the Small Municipal Separate Storm Sewer System...

    Science.gov (United States)

    2013-02-12

    ... Issuance of the Small Municipal Separate Storm Sewer System NPDES General Permit--New Hampshire AGENCY...) general permit for discharges from small Municipal Separate Storm Sewer Systems (MS4s) to certain waters... requirements of the CWA. The regulations at 40 CFR 122.26(b)(16) define a small municipal separate storm sewer...

  9. Development and testing of highway storm-sewer flow measurement and recording system

    Science.gov (United States)

    Kilpatrick, F.A.; Kaehrle, W.R.; Hardee, Jack; Cordes, E.H.; Landers, M.N.

    1985-01-01

    A comprehensive study and development of measuring instruments and techniques for measuring all components of flow in a storm-sewer drainage system was undertaken by the U.S. Geological Survey under the sponsorship of the Federal Highway Administration. The study involved laboratory and field calibration and testing of measuring flumes, pipe insert meters, weirs, electromagnetic velocity meters as well as the development and calibration of pneumatic-bubbler pressure transducer head measuring systems. Tracer-dilution and acoustic flow meter measurements were used in field verification tests. A single micrologger was used to record data from all the above instruments as well as from a tipping-bucket rain gage and also to activate on command the electromagnetic velocity meter and tracer-dilution systems. (Author 's abstract)

  10. Treatment of Y-12 storm sewer sediments and DARA soils by thermal desorption

    International Nuclear Information System (INIS)

    Morris, M.I.; Shealy, S.E.

    1995-01-01

    The 1992 Oak Ridge Reservation Federal Facilities Compliance Agreement (FFCA) listed a number of mixed wastes, subject to land disposal restrictions (LDR), for which no treatment method had been identified, and required DOE to develop strategies for treatment and ultimate disposal of those wastes. This paper presents the results of a program to demonstrate that thermal desorption can remove both organics and mercury from two mixed wastes from the DOE Y-12 facility in Oak Ridge, Tennessee. The first waste, the Y-12 Storm Sewer Sediments (SSSs) was a sediment generated from upgrades to the plant storm sewer system. This material contained over 4 percent mercury, 2 percent uranium and 350 mg/kg polychlorinated biphenyls (PCBs). Leachable mercury exceeded toxicity characteristic leaching procedure (TCLP) and LDR criteria. The second waste, the Disposal Area Remedial Action (DARA) Soils, are contaminated with uranium, mercury and PCBs. This treatability study included bench-scale testing of a thermal desorption process. Results of the testing showed that, for the SSSs, total mercury could be reduced to 120 mg/kg by treatment at 600 degrees C, which is at the high end of the temperature range for typical thermal desorption systems. Leachable TCLP mercury was less than 50 μg/L and PCBs were below 2 mg/kg. Treatment of the DARA Soils at 450 degrees C for 10 minutes resulted in residual PCBs of 0.6 to 3.0 mg/kg. This is too high (goal < 2mg/kg) and higher treatment temperatures are needed. The testing also provided information on the characteristics and quantities of residuals from the thermal desorption process

  11. The characteristics of dissolved organic matter (DOM) in storm sewer sediments and the binding interaction with Cu(II) in four typical regions in Beijing, China.

    Science.gov (United States)

    Zhang, Ziyang; Li, Kun; Zhang, Xiaoran; Li, Haiyan

    2017-07-01

    In this work, dissolved organic matter (DOM) was extracted from storm sewer sediments collected in four typical regions (residential, campus, traffic and business regions) in Beijing, China. The basic characteristics of DOM were analyzed by UV-visible spectroscopy (UV-Vis), excitation-emission matrix Fluorescence Spectroscopy and Fourier Transform Infrared Spectroscopy. Furthermore, the complexation between DOM and Cu(II) were investigated. The results showed that there were large amount of aromatic structure in the DOM extracted from storm sewer sediments. The microbial activities had also made a contribution to the DOM in storm sewer sediments. The composition of DOM influenced the complexing capacity of Cu(II) greatly, which may be attributed to the protein-like and humic-like substances in storm sewer sediments. This study demonstrated valuable information on the structure present in the DOM of storm sewer sediments and provided new insight for exploring the relationship between DOM and co-existing heavy metals in storm sewer sediments.

  12. Management of storm water in unitary sewer systems; Gestion de las aguas de tormenta en las redes de alcantarillado unitarias

    Energy Technology Data Exchange (ETDEWEB)

    Rayos, C.

    1999-08-01

    A brief review is provided of the general problems of storm waters and how they are dealt with in Directive 91/27/EEC. An experiment in Asturias, Spain, is reported in which storm water storage tanks were designed to reduce the number and impact of discharges from the unitary sewer systems. The criteria for calculating the design flows in accordance with the guidelines of Spain`s Northern Hydrographic Confederation, the procedures used in determining the size of the overflows and the different elements employed in the equipment, control systems and safety systems are all described. (Author) 31 refs.

  13. Storm water management implications on WWTPS in combined sewer systems: Integration strategies and process conditions; Implicaciones sobre la estacion depuradora de la gestion de aguas pluviales en los sistemas de saneamiento unitario: estrategias de integracion y afecciones sobre los procesos

    Energy Technology Data Exchange (ETDEWEB)

    Suarez Lopez, J.; Jacome Burgos, A.; Anta Alvarez, J.; Blanco Menendez, J. P.; Hernaez Oubina, D.; Rio Cambeses, H. del

    2012-07-01

    New design and strategies to manage wet weather floes in combined sewer systems, which main objective is to minimize environmental impacts on water bodies, require the treatment of large volumes of storm water. Wet weather flows introduced into combined sewer show dynamic-transient behavior both in terms of flow discharges and pollution. With traditional design strategies, large pollution peaks are spilled during rain events into water receiving bodies by combined sewer overflows (CSOs). Nowadays, CSOs have been reduced providing some storage capacity into the combined sewer systems (either in network, by means storm water tanks, or in WWTP). The stored storm water and its associated pollution should be treated. WWTP inflows during rainy events are conditioned by the local storm water management strategy. The WWTP can be overcome if it is managed using traditional dry weather strategies. In order to optimize the treatment performance and to assure that urban pollution do not reach aquatic environment, the WWTP must participate in the system in an integrated manner. This is a key element. This paper shows firstly the importance of CSO pollution and the development of new strategies for storm water management in combined sewer systems. Storm water tanks, located in the sewerage system, have been one of the most common solutions adopted but there are some experiences of wet weather flow management at the WWTP. All these strategies are revised in the paper. Once the role of the WWTP in the new combined sewer systems is known, the article presents a review about the problems generated by the hydraulic overloads and the large variations of the pollution characteristics on different stages of the water line. Special emphasis is made on the problems generated in secondary processes based on activated sludge. these problems are analysed in detail and some mitigation strategies are proposed. (Author) 20 refs.

  14. Storms

    International Nuclear Information System (INIS)

    Kai, Keizo; Melrose, D.B.; Suzuki, S.

    1985-01-01

    At metre and decametre wavelengths long-lasting solar radio emission, consisting of thousands of short-lived spikes superimposed on a slowly varying continuum, is observed. This type of storm emission may continue for periods ranging from a few hours to several days; the long duration is one of the characteristics which distinguish storms from other types of solar radio emission. These events are called storms or noise storms by analogy with geomagnetic storms. (author)

  15. Sewer Processes

    DEFF Research Database (Denmark)

    Hvitved-Jacobsen, Thorkild; Vollertsen, Jes; Nielsen, Asbjørn Haaning

    Since the first edition was published over a decade ago, advancements have been made in the design, operation, and maintenance of sewer systems, and new problems have emerged. For example, sewer processes are now integrated in computer models, and simultaneously, odor and corrosion problems caused...... by hydrogen sulfide and other volatile organic compounds, as well as other potential health issues, have caused environmental concerns to rise. Reflecting the most current developments, Sewer Processes: Microbial and Chemical Process Engineering of Sewer Networks, Second Edition, offers the reader updated...... and valuable information on the sewer as a chemical and biological reactor. It focuses on how to predict critical impacts and control adverse effects. It also provides an integrated description of sewer processes in modeling terms. This second edition is full of illustrative examples and figures, includes...

  16. On Hydraulic and Pollution Effects of Converting Combined Sewer Catchments to Separate Sewer Catchments

    DEFF Research Database (Denmark)

    Thorndahl, Søren Liedtke; Schaarup-Jensen, Kjeld; Rasmussen, Michael R.

    2015-01-01

    systems to become serviced with separate sewer systems decreases the volumes of storm water and pollutants diverted to the waste water treatment plant and discharged as combined sewer overflow. This happens at the expense of an increase in volumes of storm water and pollutant loads diverted to local...... receiving waters when detention ponds are not built-in the new separate sewer systems. It is concluded that consequences can be fatal for receiving waters, if no retention of pollutants is integrated into the system....

  17. The hydraulic capacity of deteriorating sewer systems.

    Science.gov (United States)

    Pollert, J; Ugarelli, R; Saegrov, S; Schilling, W; Di Federico, V

    2005-01-01

    Sewer and wastewater systems suffer from insufficient capacity, construction flaws and pipe deterioration. Consequences are structural failures, local floods, surface erosion and pollution of receiving waters bodies. European cities spend in the order of five billion Euro per year for wastewater network rehabilitation. This amount is estimated to increase due to network ageing. The project CARE-S (Computer Aided RE-habilitation of Sewer Networks) deals with sewer and storm water networks. The final project goal is to develop integrated software, which provides the most cost-efficient system of maintenance, repair and rehabilitation of sewer networks. Decisions on investments in rehabilitation often have to be made with uncertain information about the structural condition and the hydraulic performance of a sewer system. Because of this, decision-making involves considerable risks. This paper presents the results of research focused on the study of hydraulic effects caused by failures due to temporal decline of sewer systems. Hydraulic simulations are usually carried out by running commercial models that apply, as input, default values of parameters that strongly influence results. Using CCTV inspections information as dataset to catalogue principal types of failures affecting pipes, a 3D model was used to evaluate their hydraulic consequences. The translation of failures effects in parameters values producing the same hydraulic conditions caused by failures was carried out through the comparison of laboratory experiences and 3D simulations results. Those parameters could be the input of 1D commercial models instead of the default values commonly inserted.

  18. Sewer System Management Plan.

    Energy Technology Data Exchange (ETDEWEB)

    Holland, Robert C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-08-01

    A Sewer System Management Plan (SSMP) is required by the State Water Resources Control Board (SWRCB) Order No. 2006-0003-DWQ Statewide General Waste Discharge Requirements (WDR) for Sanitary Sewer Systems (General Permit). DOE, National Nuclear Security Administration (NNSA), Sandia Field Office has filed a Notice of Intent to be covered under this General Permit. The General Permit requires a proactive approach to reduce the number and frequency of sanitary sewer overflows (SSOs) within the State. SSMPs must include provisions to provide proper and efficient management, operation, and maintenance of sanitary sewer systems and must contain a spill response plan.

  19. An Environmental Innovation: The Sewer Mouse

    Science.gov (United States)

    1979-01-01

    In the effort to clean up America's waters, there is a little-known complicating factor: because they leak, sewer systems in many American cities are causing rather than preventing pollution of rivers and lakes. Fixing the leaks is difficult because their locations are unknown. Maintenance crews can't tear up a whole city looking for cracks in the pipes; they must first determine which areas are most likely suspects. An aerospace spinoff is providing help in that regard. The problem starts with heavy rains. Rainwater naturally flows into the sewers from streets, but sewage systems are designed to accommodate it. However, they are not designed to handle the additional flow of "groundwater", rain absorbed by the earth which seeps into the sewers through leaks in pipes and sewer walls. After a storm, groundwater seepage can increase the waterflow to deluge proportions, with the result that sewage treatment plants are incapable of processing the swollen flow. When that happens the sluices must be opened, dumping raw sewage into rivers and lakes.

  20. City sewer collectors biocorrosion

    Science.gov (United States)

    Ksiażek, Mariusz

    2014-12-01

    This paper presents the biocorrosion of city sewer collectors impregnated with special polymer sulphur binders, polymerized sulphur, which is applied as the industrial waste material. The city sewer collectors are settled with a colony of soil bacteria which have corrosive effects on its structure. Chemoautotrophic nitrifying bacteria utilize the residues of halites (carbamide) which migrate in the city sewer collectors, due to the damaged dampproofing of the roadway and produce nitrogen salts. Chemoorganotrophic bacteria utilize the traces of organic substrates and produce a number of organic acids (formic, acetic, propionic, citric, oxalic and other). The activity of microorganisms so enables the origination of primary and secondary salts which affect physical properties of concretes in city sewer collectors unfavourably.

  1. The Historical Development of Sewers Worldwide

    Directory of Open Access Journals (Sweden)

    Giovanni De Feo

    2014-06-01

    Full Text Available Although there is evidence of surface-based storm drainage systems in early Babylonian and Mesopotamian Empires in Iraq (ca. 4000–2500 BC, it is not until after ca. 3000 BC that we find evidence of the well organized and operated sewer and drainage systems of the Minoans and Harappans in Crete and the Indus valley, respectively. The Minoans and Indus valley civilizations originally, and the Hellenes and Romans thereafter, are considered pioneers in developing basic sewerage and drainage technologies, with emphasis on sanitation in the urban environment. The Hellenes and Romans further developed these techniques and greatly increased the scale of these systems. Although other ancient civilizations also contributed, notably some of the Chinese dynasties, very little progress was made during the Dark ages from ca. 300 AD through to the middle of the 18th century. It was only from 1850 onwards that that modern sewerage was “reborn”, but many of the principles grasped by the ancients are still in use today. This paper traces the development of the sewer from those earliest of civilizations through to the present day and beyond. A 6000 year technological history is a powerful validation of the vital contribution of sewers to human history.

  2. DETENTION TANKS AS A MEANS OF URBAN STORM WATER ...

    African Journals Online (AJOL)

    sewers and detention tanks. That is, for sewers the peak value, t,, and for detention tanks the total, t-i, is used, which are computed as follows: • = Maxq. P. Maxr. (3) ..... infrastructure, like water supply, power supply, storm and wastewater management, etc. A change or new development in the mode of settlement of a certain ...

  3. Uncertainties Related to Extreme Event Statistics of Sewer System Surcharge and Overflow

    DEFF Research Database (Denmark)

    Schaarup-Jensen, Kjeld; Johansen, C.; Thorndahl, Søren Liedtke

    2005-01-01

    Today it is common practice - in the major part of Europe - to base design of sewer systems in urban areas on recommended minimum values of flooding frequencies related to either pipe top level, basement level in buildings or level of road surfaces. Thus storm water runoff in sewer systems is only...... proceeding in an acceptable manner, if flooding of these levels is having an average return period bigger than a predefined value. This practice is also often used in functional analysis of existing sewer systems. If a sewer system can fulfil recommended flooding frequencies or not, can only be verified...... by performing long term simulations - using a sewer flow simulation model - and draw up extreme event statistics from the model simulations. In this context it is important to realize that uncertainties related to the input parameters of rainfall runoff models will give rise to uncertainties related...

  4. Impervious surfaces and sewer pipe effects on stormwater runoff temperature

    Science.gov (United States)

    Sabouri, F.; Gharabaghi, B.; Mahboubi, A. A.; McBean, E. A.

    2013-10-01

    The warming effect of the impervious surfaces in urban catchment areas and the cooling effect of underground storm sewer pipes on stormwater runoff temperature are assessed. Four urban residential catchment areas in the Cities of Guelph and Kitchener, Ontario, Canada were evaluated using a combination of runoff monitoring and modelling. The stormwater level and water temperature were monitored at 10 min interval at the inlet of the stormwater management ponds for three summers 2009, 2010 and 2011. The warming effect of the ponds is also studied, however discussed in detail in a separate paper. An artificial neural network (ANN) model for stormwater temperature was trained and validated using monitoring data. Stormwater runoff temperature was most sensitive to event mean temperature of the rainfall (EMTR) with a normalized sensitivity coefficient (Sn) of 1.257. Subsequent levels of sensitivity corresponded to the longest sewer pipe length (LPL), maximum rainfall intensity (MI), percent impervious cover (IMP), rainfall depth (R), initial asphalt temperature (AspT), pipe network density (PND), and rainfall duration (D), respectively. Percent impervious cover of the catchment area (IMP) was the key parameter that represented the warming effect of the paved surfaces; sensitivity analysis showed IMP increase from 20% to 50% resulted in runoff temperature increase by 3 °C. The longest storm sewer pipe length (LPL) and the storm sewer pipe network density (PND) are the two key parameters that control the cooling effect of the underground sewer system; sensitivity analysis showed LPL increase from 345 to 966 m, resulted in runoff temperature drop by 2.5 °C.

  5. DEP Reported Sanitary Sewer Overflows

    Data.gov (United States)

    Montgomery County of Maryland — Sanitary sewer overflows reported to the Department of Environmental Protection by the Washington Suburban Sanitary Commission or individuals in the County. Update...

  6. [Transport and sources of runoff pollution from urban area with combined sewer system].

    Science.gov (United States)

    Li, Li-Qing; Yin, Cheng-Qing

    2009-02-15

    Sampling and monitoring of runoff and sewage water in Wuhan urban area with combined sewer system were carried out during the period from 2003 to 2006, to study the transport and sources of runoff pollution at the catchment scale coupled with environmental geochemistry method. The results showed a change in quality between the runoff entering the sewer network and the combined storm water flow at the sewer's outlet. A significant increase was observed in the concentrations of total suspended solids (TSS), volatile suspended solids (VSS), COD, TN, and TP, and in the proportion of COD linked to particles. During the runoff production and transport, the concentrations of TSS and COD increased from 18.7 mg/L and 37.0 mg/L in roof runoff, to 225.3 mg/L and 176.5 mg/L in street runoff, and to 449.7 mg/L and 359.9 mg/L in combined storm water flow, respectively. The proportion of COD linked to particles was increased by 18%. In addition, the total phosphorus (P) and iron (Fe) contents in urban ground dust, storm drain sediment, sewage sewer sediment and combined sewer sediment were measured to identify the potential sources of suspended solids in the combined flow. The urban ground dust andstorm drain sediment wererich in Fe, whereas the sewage sewer sediment was rich in P. The P/Fe ratios in these groups were significantly distinct and able to differentiate them. A calculation of the two storm events based on the P/Fe rations showed that 56% +/- 26% of suspended solids in combined flow came from urban ground and storm drain. The rest wer e originated from the sewage sewer sediments which deposited in combined sewer on the dry weather days and were eroded on the wet weather days. The combined sewer network not only acts as a transport system, but also constitutes a physicochemical reactor that degrades the quality of urban water. Reducing the in-sewer pollution stocks would effectively control urban runoff pollution.

  7. COMBINED-SEWER OVERFLOW CONTROL AND TREATMENT

    Science.gov (United States)

    Combined-sewer overflow (CSO), along with sanitary-sewer overflow and stormwater are significant contributors of contamination to surface waters. During a rain event, the flow in a combined sewer system may exceed the capacity of the intercepting sewer leading to the wastewater t...

  8. Optimization of the central automatic control of a small Dutch sewer system

    Science.gov (United States)

    Kolechkina, A. G.; Hoes, O. A. C.

    2012-04-01

    A sewer control system was developed in the context of a subsidized project aiming at improvement of surface water quality by control of sewer systems and surface water systems. The project was coordinated by the local water board, "Waterschap Hollandse Delta". Other participants were Delft University of Technology, Deltares and the municipalities Strijen, Cromstrijen, Westmaas, Oud Beijerland and Piershil. As part of the project there were two pilot implementations where a central automatic controller was coupled to the existing SCADA system. For these two pilots the system is now operational. A Dutch urban area in the western part of the Netherlands is usually part of a polder, which is effectively an artificially drained catchment. The urban area itself is split into small subcatchments that manage runoff in different ways. In all cases a large fraction goes into the natural hydrological cycle, but, depending on the design of the local sewer system, a larger or smaller part finds its way into the sewer system. Proper control of this flow is necessary to control surface water quality and to avoid health risks from flow from the sewer into the streets. At each time step the controller switches pumps to distribute the remaining water in the system at the end of the time step over the different subcatchments. The distribution is created based on expert judgment of the relative vulnerability and subcatchment sewer system water quality. It is implemented in terms curves of total system stored volume versus subcatchment stored volume. We describe the process of the adaptation of a controller to two different sewer systems and the understanding of the artificial part of the catchment we gained during this process. In the process of adaptation the type of sewer system (combined foul water and storm water transport or separate foul water and storm water transport) played a major role.

  9. Modelling of flow and settling in storm water sedimentation tanks

    NARCIS (Netherlands)

    Kluck, J.

    1994-01-01

    In the near future in the Netherlands many reservoirs will have to be built to abate the pollution of the surface water by overflowing storm water from combined sewer systems [Kluck, 1992-a]. These reservoirs, called storm water sedimentation tanks, reduce the pollution in two ways. The most

  10. New approach for receiving water objectives for overflows from sewer systems

    DEFF Research Database (Denmark)

    Larsen, Torben

    1999-01-01

    The paper describes the results of the work for the establishment of consistent objectives for storm overflows from sewer systems in respect to the physical conditions in streams and rivers in Denmark. First the result of a questionnaire is mentioned. Next some principles of the methods for formu...

  11. Priority substances in combined sewer overflows: case study of the Paris sewer network.

    Science.gov (United States)

    Gasperi, J; Garnaud, S; Rocher, V; Moilleron, R

    2011-01-01

    This study was undertaken to supply data on both priority pollutant (PP) occurrence and concentrations in combined sewer overflows (CSOs). A single rain event was studied on 13 sites within the Paris sewer network. For each sample, a total of 66 substances, including metals, polycyclic aromatic hydrocarbons (PAHs), pesticides, organotins, volatile organic compounds, chlorobenzenes, phthalates and alkylphenols were analyzed. Of the 66 compounds analyzed in all, 40 PPs including 12 priority hazardous substances were detected in CSOs. As expected, most metals were present in all samples, reflecting their ubiquitous nature. Chlorobenzenes and most pesticides were never quantified above the limit of quantification, while the majority of the other organic pollutants, except DEHP (median concentration: 22 μg.l(-1)), were found to lie in the μg.l(-1) range. For the particular rain event studied, the pollutant loads discharged by CSOs were evaluated and then compared to pollutant loads conveyed by the Seine River. Under the hydraulic conditions considered and according to the estimations performed, this comparison suggests that CSOs are potentially significant local source of metals, PAHs and DEHP. Depending on the substance, the ratio between the CSO and Seine River loads varied from 0.5 to 26, underscoring the important local impact of CSOs at the scale of this storm for most pollutants.

  12. Modelling of flow and settling in storm water sedimentation tanks

    OpenAIRE

    Kluck, J.

    1994-01-01

    In the near future in the Netherlands many reservoirs will have to be built to abate the pollution of the surface water by overflowing storm water from combined sewer systems [Kluck, 1992-a]. These reservoirs, called storm water sedimentation tanks, reduce the pollution in two ways. The most important is by simply storing a part of the sewage (waste water and storm water) and thus reducing the quantity of overflowing water. The second is by providing flow conditions in which particles can set...

  13. Biodegradability of organic matter associated with sewer sediments during first flush.

    Science.gov (United States)

    Sakrabani, Ruben; Vollertsen, Jes; Ashley, Richard M; Hvitved-Jacobsen, Thorkild

    2009-04-01

    The high pollution load in wastewater at the beginning of a rain event is commonly known to originate from the erosion of sewer sediments due to the increased flow rate under storm weather conditions. It is essential to characterize the biodegradability of organic matter during a storm event in order to quantify the effect it can have further downstream to the receiving water via discharges from Combined Sewer Overflow (CSO). The approach is to characterize the pollutograph during first flush. The pollutograph shows the variation in COD and TSS during a first flush event. These parameters measure the quantity of organic matter present. However these parameters do not indicate detailed information on the biodegradability of the organic matter. Such detailed knowledge can be obtained by dividing the total COD into fractions with different microbial properties. To do so oxygen uptake rate (OUR) measurements on batches of wastewater have shown itself to be a versatile technique. Together with a conceptual understanding of the microbial transformation taking place, OUR measurements lead to the desired fractionation of the COD. OUR results indicated that the highest biodegradability is associated with the initial part of a storm event. The information on physical and biological processes in the sewer can be used to better manage sediment in sewers which can otherwise result in depletion of dissolved oxygen in receiving waters via discharges from CSOs.

  14. Effects of combined-sewer overflows and urban runoff on the water quality of Fall Creek, Indianapolis, Indiana

    Science.gov (United States)

    Martin, Jeffrey D.

    1995-01-01

    In 1986, the U.S. Geological Survey and the Indianapolis Department of Public Works began a study to evaluate the effects of combined-sewer overflows and urban runoff discharging to Fall Geek on the White River. This report describes the effects of combined-sewer overflows and urban runoff on the water quality of Fall Creek during summer 1987 by comparing the water quality during base flow with that during storm runoff and by comparing water quality in the urbanized area with that in the less urbanized area upstream from the combined-sewer overflows. Data were collected at three streamflow-gaging stations located upstream from, downstream from, and in the middle of 27 combined-sewer overflows on Fall Creek. The most downstream station also was immediately downstream from the discharge of filter backwash from a water-treatment plant for public supply.

  15. Effluent and sanitary sewer monitors

    International Nuclear Information System (INIS)

    Stanchi, L.; Vasey, M.R.

    1977-03-01

    Two similar instruments that monitor the liquid wastes from the plutonium facility are described. The operation of the two instruments is completely automatic and performs a continuous surveillance in the frame of Nuclear Safeguards. One instrument controls the liquids from the facility and the other checks the sanitary sewer wastes. Both have self-diagnosing capabilities and take automatic actions in case of abnormal occurrences

  16. Locations of Combined Sewer Overflow Outfalls - US EPA Region 3

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data layer identifies the locations of Combined sewer overflow outfalls. Combined sewer systems are sewers that are designed to collect rainwater runoff,...

  17. Potential of turbidity monitoring for real time control of pollutant discharge in sewers during rainfall events

    OpenAIRE

    LACOUR, Céline; JOANNIS, Claude; GROMAIRE, MC; CHEBBO, Ghassan

    2009-01-01

    Turbidity sensors can be used to continuously monitor the evolution of pollutant mass discharge. For two sites within the Paris combined sewer system, continuous turbidity, conductivity and flow data were recorded at one-minute time intervals over a one-year period. This paper is intended to highlight the variability in turbidity dynamics during wet weather. For each storm event, turbidity response aspects were analysed through different classifications. The correlation between classification...

  18. Learning Storm

    CERN Document Server

    Jain, Ankit

    2014-01-01

    If you are a Java developer who wants to enter into the world of real-time stream processing applications using Apache Storm, then this book is for you. No previous experience in Storm is required as this book starts from the basics. After finishing this book, you will be able to develop not-so-complex Storm applications.

  19. Loads of Sewer Manholes within Mining Area

    Directory of Open Access Journals (Sweden)

    Magdalena Zięba

    2014-01-01

    Originality/Value: The presented method is an original concept. It enables the determination of additional external horizontal loads acting on sewer manholes within mining areas, in particular the flexible manholes made of thermoplastics. It also enables the determination of dependencies of changes in the cross-sections of risers of flexible sewer manholes (with different circumferential stiffness on the horizontal soil strains.

  20. The Sewer Research Station in Frejlev

    DEFF Research Database (Denmark)

    Schaarup-Jensen, Kjeld; Hvitved-Jacobsen, T.

    This report for the 2000 activities at the sewer research station in Frejlev. Only few - if any - sewer monitoring stations like the one in Frejlev exist. Without no doubt the field data produced - especially the time series - in the course of time will serve as a unique basis for projects dealin...

  1. The Sewer Research Station in Frejlev

    DEFF Research Database (Denmark)

    Hvitved-Jacobsen, Thorkild; Schaarup-Jensen, Kjeld

    This report for the 1999 activities at the sewer research station in Frejlev. Only few - if any - sewer monitoring stations like the one in Frejlev exist. Without no doubt the field data produced - especially the time series - in the course of time will serve as a unigue basis for projects dealin...

  2. Information use in Dutch sewer assest management

    NARCIS (Netherlands)

    Van Riel, W.A.P.; Langeveld, J.G.; Herder, P.M.; Clemens, F.H.L.R.

    2012-01-01

    Sewer systems are capital-intensive infrastructures, requiring appropriate asset management to safeguard serviceability. In the Netherlands, effective sewer asset management is described by De Leeuw’s control paradigm. Reliable data and information are key elements in decision-making for

  3. Leveraging Spatial Data to Assess Where Sewers Leak and Impinge on Urban Water Quality

    Science.gov (United States)

    Holden, P. A.; Roehrdanz, P.; Lee, D. G.; Feraud, M.; Maier, M.; Means, J. C.; Snyder, S.

    2017-12-01

    In the modern urban water environment (UWE), engineered systems provide wastewater collection, treatment, and reuse; stormwater and graywater management; and potable water treatment, distribution and conservation. Underpinning such systems are physical, private and public, infrastructures whose integrities impinge on major goals of protecting groundwater and surface water resources, managing flooding, and securing safe drinking water. Here we study sanitary sewers, i.e. the main pipes in wastewater collection systems that improve public health by reducing pathogen exposure, and that afford reclaiming water for beneficial reuse. We ask: what is the relationship between sanitary sewer integrity and nearby water quality? Research methods include acquiring spatially defined sewer metadata that are analyzed using a published pipe leakage algorithm with variables of age, depth, materials of construction, length, diameter, slope, and nature of overburden. By executing the algorithm within a geographical information system (GIS), coupled with relating leakage probabilities to shallow groundwater table proximities—also digitally assembled, from well depth data—maps of wastewater exfiltration scores were produced for a city. Field sampling shallow groundwater allowed assessing concentrations of wastewater indicator compounds including personal care products and pharmaceuticals (PCPPs), and showing positive relationships between wastewater exfiltration scores and tryptophan-like fluorescence (TLF), reactive nitrogen species, an artificial sweetener acesulfame, and a stable isotope of oxygen (δ18O). The approach is extended to surface waters, where exfiltrating wastewater may transport from leaking sanitary sewers through the unsaturated zone to nearby storm drains or to storm drains that are submerged in contaminated groundwater. Spatially assessing sewer interactions within the UWE, as such, could aid urban infrastructure management and investment.

  4. Gamma and beta logging of underground sewer and process lines

    International Nuclear Information System (INIS)

    Rangel, M.J.; Martz, D.E.; Langner, G.H. Jr.

    1989-11-01

    The GammaSnake can be useful for locating uranium mill tailings used as backfill for sewer lines or storm drains where the lines can be readily accessed from a cleanout access port or other opening. The time required to determine if contamination is present using the GammaSnake method is considerably less than when using the delta gamma or drilling methods. There is, also, less potential hazard to the equipment operators when using the GammaSnake method. The GammaSnake method is generally limited to a distance of 100 feet or less. Used with the MAC-51B line locator, the GammaSnake method can provide useful information without extensive drilling or surveying. 7 figs., 2 tabs

  5. A review of the Y-12 Plant discharge of enriched uranium to the sanitary sewer (DEUSS)

    International Nuclear Information System (INIS)

    1991-09-01

    The Oak Ridge Y-12 Plant is situated adjacent to the Oak Ridge city limits and is operated by the United States Department of Energy (DOE). The Y-12 Plant is located on 4,860 acres, which is collectively referred to as the Y-12 Plant site. Among the missions for which the facility is in existence are producing nuclear weapons components, supporting weapon design laboratories, and processing special nuclear materials (SNM). The Y-12 Plant is under the regulatory guidance of DOE Order 5400.5 and has complied with the technical requirements governing SNM since its issue. However, an in-depth review with appropriate documentation had not been performed, prior to the effect presented herein, to substantiate this claim. As a result of the solid waste issue, it was determined that other types of waste should be formally reviewed for content with respect to SNM. Therefore, a project was formed to investigate the conveyance of SNM through the sanitary sewer system. It is emphasized that this project addresses only effluent from the sanitary sewer system and not the storm sewer system. The project reviewed sanitary sewer data both for the Y-12 Plant and the Y-12 Plant site

  6. Trace element carriers in combined sewer during dry and wet weather: an electron microscope investigation.

    Science.gov (United States)

    El Samrani, A G; Lartiges, B S; Ghanbaja, J; Yvon, J; Kohler, A

    2004-04-01

    The nature of trace element carriers contained in sewage and combined sewer overflow (CSO) was investigated by TEM-EDX-Electron diffraction and SEM-EDX. During dry weather, chalcophile elements were found to accumulate in sewer sediments as early diagenetic sulfide phases. The sulfurization of some metal alloys was also evidenced. Other heavy metal carriers detected in sewage include metal alloys, some iron oxihydroxide phases and neoformed phosphate minerals such as anapaite. During rain events, the detailed characterization of individual mineral species allowed to differentiate the contributions from various specific sources. Metal plating particles, barite from automobile brake, or rare earth oxides from catalytic exhaust pipes, originate from road runoff, whereas PbSn alloys and lead carbonates are attributed to zinc-works from roofs and paint from building siding. Soil contribution can be traced by the presence of clay minerals, iron oxihydroxides, zircons and rare earth phosphates. However, the most abundant heavy metal carriers in CSO samples were the sulfide particles eroded from sewer sediments. The evolution of relative abundances of trace element carriers during a single storm event, suggests that the pollution due to the "first flush" effect principally results from the sewer stock of sulfides and previously deposited metal alloys, rather than from urban surface runoff.

  7. A review of the Y-12 Plant discharge of enriched uranium to the sanitary sewer (DEUSS)

    Energy Technology Data Exchange (ETDEWEB)

    1991-09-01

    The Oak Ridge Y-12 Plant is situated adjacent to the Oak Ridge city limits and is operated by the United States Department of Energy (DOE). The Y-12 Plant is located on 4,860 acres, which is collectively referred to as the Y-12 Plant site. Among the missions for which the facility is in existence are producing nuclear weapons components, supporting weapon design laboratories, and processing special nuclear materials (SNM). The Y-12 Plant is under the regulatory guidance of DOE Order 5400.5 and has complied with the technical requirements governing SNM since its issue. However, an in-depth review with appropriate documentation had not been performed, prior to the effect presented herein, to substantiate this claim. As a result of the solid waste issue, it was determined that other types of waste should be formally reviewed for content with respect to SNM. Therefore, a project was formed to investigate the conveyance of SNM through the sanitary sewer system. It is emphasized that this project addresses only effluent from the sanitary sewer system and not the storm sewer system. The project reviewed sanitary sewer data both for the Y-12 Plant and the Y-12 Plant site.

  8. Model Predictive Control of Sewer Networks

    DEFF Research Database (Denmark)

    Pedersen, Einar B.; Herbertsson, Hannes R.; Niemann, Henrik

    2016-01-01

    The developments in solutions for management of urban drainage are of vital importance, as the amount of sewer water from urban areas continues to increase due to the increase of the world’s population and the change in the climate conditions. How a sewer network is structured, monitored and cont...... benchmark model. Due to the inherent constraints the applied approach is based on Model Predictive Control....

  9. Research note: Mapping spatial patterns in sewer age, material, and proximity to surface waterways to infer sewer leakage hotspots

    Science.gov (United States)

    Hopkins, Kristina G.; Bain, Daniel J.

    2018-01-01

    Identifying areas where deteriorating sewer infrastructure is in close proximity to surface waterways is needed to map likely connections between sewers and streams. We present a method to estimate sewer installation year and deterioration status using historical maps of the sewer network, parcel-scale property assessment data, and pipe material. Areas where streams were likely buried into the sewer system were mapped by intersecting the historical stream network derived from a 10-m resolution digital elevation model with sewer pipe locations. Potential sewer leakage hotspots were mapped by identifying where aging sewer pipes are in close proximity (50-m) to surface waterways. Results from Pittsburgh, Pennsylvania (USA), indicated 41% of the historical stream length was lost or buried and the potential interface between sewers and streams is great. The co-location of aging sewer infrastructure (>75 years old) near stream channels suggests that 42% of existing streams are located in areas with a high potential for sewer leakage if sewer infrastructure fails. Mapping the sewer-stream interface provides an approach to better understand areas were failing sewers may contribute a disproportional amount of nutrients and other pathogens to surface waterways.

  10. Simulating groundwater-induced sewer flooding

    Science.gov (United States)

    Mijic, A.; Mansour, M.; Stanic, M.; Jackson, C. R.

    2016-12-01

    During the last decade, Chalk catchments of southern England experienced severe groundwater flooding. High groundwater levels resulted in the groundwater ingress into the sewer network that led to restricted toilet use and the overflow of diluted, but untreated sewage to road surfaces, rivers and water courses. In response to these events the water and sewerage company Thames Water Utilities Ltd (TWUL) had to allocate significant funds to mitigate the impacts. It was estimated that approximately £19m was spent responding to the extreme wet weather of 2013-14, along with the use of a fleet of over 100 tankers. However, the magnitude of the event was so large that these efforts could not stop the discharge of sewage to the environment. This work presents the analysis of the risk of groundwater-induced sewer flooding within the Chalk catchment of the River Lambourn, Berkshire. A spatially distributed groundwater model was used to assess historic groundwater flood risk and the potential impacts of changes in future climate. We then linked this model to an urban groundwater model to enable us to simulate groundwater-sewer interaction in detail. The modelling setup was used to identify relationships between infiltration into sewers and groundwater levels at specific points on TWUL's sewer network, and to estimate historic and future groundwater flood risk, and how this varies across the catchment. The study showed the significance of understanding the impact of groundwater on the urban water systems, and producing information that can inform a water company's response to groundwater flood risk, their decision making process and their asset management planning. However, the knowledge gained through integrated modelling of groundwater-sewer interactions has highlighted limitations of existing approaches for the simulation of these coupled systems. We conclude this work with number of recommendations about how to improve such hydrological/sewer analysis.

  11. Oahu Sewer Lateral Lines, Oahu County HI, 2016, Honolulu GIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — Inventory of sewer laterals, used for tracking, monitoring, and flow analysis as maintained by Honolulu ENV Department of Environmental Services. The base sewer...

  12. Oahu Sewer Main Lines, Oahu County HI, 2016, Honolulu GIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — Linear features representing sewer main lines as maintained by Honolulu ENV Department of Environmental Services. Includes an inventory of sewer mains used for...

  13. Sewerage Service Areas - MDC_SewerServiceArea

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — The Water and Sewer Service Area layer was derived from the original paper based sketches which contained both water and sewer utility boundary information. This...

  14. Oahu Sewer Manhole Points, Oahu County HI, 2016, Honolulu GIS

    Data.gov (United States)

    U.S. Environmental Protection Agency — Point features representing sewer manholes as maintained by Honolulu ENV Department of Environmental Services. This inventory of sewer manholes used by tracking,...

  15. The fate of radioactivity in sewers

    International Nuclear Information System (INIS)

    2000-01-01

    The Environment Agencies authorise and monitor the disposal of low-level radioactive waste to sewers. Such discharges originate from non-nuclear sites such as hospitals, universities and research centres. Discharges are strictly controlled through authorisations, which place conditions and limits on the disposer. We commissioned the work summarised within this, leaflet to reassess the fate of these radioactive discharges and to ensure that this practice remains acceptable and is still the best option for disposal. In all cases the study found assessed radiation doses (associated with these discharges) to be a small fraction of the public dose limit. The Environment Agencies conclude from this study that the disposal of radioactive waste to sewers remains the best option available to ensure the safety of the public (including sewer workers) and to protect the environment

  16. FLUSHING FOR SEWER SEDIMENT, CORROSION, AND POLLUTION CONTROL

    Science.gov (United States)

    This paper overviews causes of combined-sewer deterioration and their heavy pollutant discharges caused by rain events together with a discussion of their control methods. In particular, it covers in-sewer and combined-sewer overflow (CSO) storage-tank-flushing systems for removi...

  17. Analysis and integrated modelling of groundwater infiltration to sewer networks

    DEFF Research Database (Denmark)

    Thorndahl, Søren Liedtke; Balling, Jonas Dueholm; Larsen, Uffe Bay Bøgh

    2016-01-01

    Infiltration of groundwater to sewer systems is a problem for the capacity of the system as well as for treatment processes at waste water treatment plants. This paper quantifies the infiltration of groundwater to a sewer system in Frederikshavn Municipality, Denmark, by measurements of sewer flo...

  18. Predicting concrete corrosion of sewers using artificial neural network.

    Science.gov (United States)

    Jiang, Guangming; Keller, Jurg; Bond, Philip L; Yuan, Zhiguo

    2016-04-01

    Corrosion is often a major failure mechanism for concrete sewers and under such circumstances the sewer service life is largely determined by the progression of microbially induced concrete corrosion. The modelling of sewer processes has become possible due to the improved understanding of in-sewer transformation. Recent systematic studies about the correlation between the corrosion processes and sewer environment factors should be utilized to improve the prediction capability of service life by sewer models. This paper presents an artificial neural network (ANN)-based approach for modelling the concrete corrosion processes in sewers. The approach included predicting the time for the corrosion to initiate and then predicting the corrosion rate after the initiation period. The ANN model was trained and validated with long-term (4.5 years) corrosion data obtained in laboratory corrosion chambers, and further verified with field measurements in real sewers across Australia. The trained model estimated the corrosion initiation time and corrosion rates very close to those measured in Australian sewers. The ANN model performed better than a multiple regression model also developed on the same dataset. Additionally, the ANN model can serve as a prediction framework for sewer service life, which can be progressively improved and expanded by including corrosion rates measured in different sewer conditions. Furthermore, the proposed methodology holds promise to facilitate the construction of analytical models associated with corrosion processes of concrete sewers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. FLUSHING FOR SEWER SEDIMENT, CORROSION, AND POLLUTION CONTROL

    Science.gov (United States)

    This presentation overviews causes of sewer deterioration and heavy pollutant discharges caused by rain events together with a discussion of their control methods. In particular, it covers in-sewer- and combined sewer overflow- (CSO-) storage-tank-flushing systems for removal of ...

  20. Water Hammer in Pumped Sewer Mains

    DEFF Research Database (Denmark)

    Larsen, Torben

    of transients in pumped pipeline systems. This present publication can be understood as the second and revised edition of the pamphlet ”Transients in pumped sewer mains” (2006) which was published as a technical report by The EVA committee under The Danish Water Pollution Committee (The Danish Society......This publication is intended for students and engineers seeking an introduction to the problem of water transients in pumped sewer and water mains. This is a subject of increasing interest because of the development of larger and more integrated systems. Consideration of transients is essential...

  1. A Monte-Carlo-Based Method for the Optimal Placement and Operation Scheduling of Sewer Mining Units in Urban Wastewater Networks

    Directory of Open Access Journals (Sweden)

    Eleftheria Psarrou

    2018-02-01

    Full Text Available Pressures on water resources, which have increased significantly nowadays mainly due to rapid urbanization, population growth and climate change impacts, necessitate the development of innovative wastewater treatment and reuse technologies. In this context, a mid-scale decentralized technology concerning wastewater reuse is that of sewer mining. It is based on extracting wastewater from a wastewater system, treating it on-site and producing recycled water applicable for non-potable uses. Despite the technology’s considerable benefits, several challenges hinder its implementation. Sewer mining disturbs biochemical processes inside sewers and affects hydrogen sulfide build-up, resulting in odor, corrosion and health-related problems. In this study, a tool for optimal sewer mining unit placement aiming to minimize hydrogen sulfide production is presented. The Monte-Carlo method coupled with the Environmental Protection Agency’s Storm Water Management Model (SWMM is used to conduct multiple simulations of the network. The network’s response when sewage is extracted from it is also examined. Additionally, the study deals with optimal pumping scheduling. The overall methodology is applied in a sewer network in Greece providing useful results. It can therefore assist in selecting appropriate locations for sewer mining implementation, with the focus on eliminating hydrogen sulfide-associated problems while simultaneously ensuring that higher water needs are satisfied.

  2. Geomagnetic storms

    International Nuclear Information System (INIS)

    McNamara, A.G.

    1980-01-01

    Disturbances due to geomagnetic storms can affect the functioning of communications satellites and of power lines and other long conductors. Two general classes of geomagnetic activity can be distinguished: ionospheric current flow (the auroral electrojet), and magnetospheric compression. Super magnetic storms, such as the one of August 1972, can occur at any time and average about 17 occurrences per century. Electrical transmission systems can be made more tolerant of such events at a price, but the most effective way to minimize damage is by better operator training coupled with effective early warning systems. (LL)

  3. MANUAL: REAL TIME CONTROL OF COMBINED SEWERS

    Science.gov (United States)

    Managers, engineers, and operators of combined urban sewer systems are faced with difficult problems related to the operation and maintenance of their facilities. In addition to the issues related to the operation and upkeep of the system, many sewerage agencies are facing increa...

  4. Value of Information for Sewer Replacement Decisions

    NARCIS (Netherlands)

    Van Riel, W.A.P.; Langeveld, J.G.; Herder, P.M.; Clemens, F.H.L.R.

    2014-01-01

    Decision-making for sewer asset management is partially based on intuition and often lacks explicit argumentation, hampering decision transparency and reproducibility. It is unknown to what extent each information source is appreciated by decision makers. Further insight into this relative

  5. Water Hammer in Pumped Sewer Mains

    DEFF Research Database (Denmark)

    Larsen, Torben

    This publication is intended for engineers seeking an introduction to the problem of water hammer in pumped pressure mains. This is a subject of increasing interest because of the development of larger and more integrated sewer systems. Consideration of water hammer is essential for structural...

  6. Agile Design of Sewer System Control

    NARCIS (Netherlands)

    Van Nooijen, R.P.; Kolechkina, A.G.; Van Leeuwen, P.E.R.M.; Van Velzen, E.

    2011-01-01

    We describe the first part of an attempt to include stakeholder participation in the design of a central automatic controller for a sewer system in a small pilot project (five subcatchments) and present lessons learned so far. The pilot is part of a project aimed at the improvement of water quality

  7. Locations of Combined Sewer Overflow Outfalls - US EPA Region 3

    Science.gov (United States)

    This data layer identifies the locations of Combined sewer overflow outfalls. Combined sewer systems are sewers that are designed to collect rainwater runoff, domestic sewage, and industrial wastewater in the same pipe. Most of the time, combined sewer systems transport all of their wastewater to a sewage treatment plant, where it is treated and then discharged to a water body. During periods of heavy rainfall or snowmelt, however, the wastewater volume in a combined sewer system can exceed the capacity of the sewer system or treatment plant. For this reason, combined sewer systems are designed to overflow occasionally and discharge excess untreated wastewater directly to nearby streams, rivers, or other water bodies. For further information visit: http://cfpub1.epa.gov/npdes/home.cfm?program_id=5

  8. Estimation of combined sewer overflow discharge

    DEFF Research Database (Denmark)

    Ahm, Malte; Thorndahl, Søren Liedtke; Nielsen, Jesper Ellerbæk

    2016-01-01

    Combined sewer overflow (CSO) structures are constructed to effectively discharge excess water during heavy rainfall, to protect the urban drainage system from hydraulic overload. Consequently, most CSO structures are not constructed according to basic hydraulic principles for ideal measurement......-balance in combined sewer catchments. A closed mass-balance is an advantage for calibration of all urban drainage models based on mass-balance principles. This study presents three different software sensor concepts based on local water level sensors, which can be used to estimate CSO discharge volumes from hydraulic...... complex CSO structures. The three concepts was tested and verified under real practical conditions. All three concepts were accurate when compared to electromagnetic flow measurements....

  9. A Sediment Transport Model for Sewers

    DEFF Research Database (Denmark)

    Mark, Ole; Larsson, Johan; Larsen, Torben

    1993-01-01

    This paper describes a mathematical model for transport processes in sewers. The model consists of three sub models, a surface model for the description of the buildup and the washoff of sediment particles from the surface area, a morphological model and an advection-dispersion model. The model i...... is being developed as a part of a study being carried out at the University of Aalborg, Denmark and VBB VIAK, Sweden. The project is funded by the Swedish Water and Waste Water Works Association and the Nordic Industrial Foundation.......This paper describes a mathematical model for transport processes in sewers. The model consists of three sub models, a surface model for the description of the buildup and the washoff of sediment particles from the surface area, a morphological model and an advection-dispersion model. The model...

  10. Prediction of organic combined sewer sediment release and transport

    OpenAIRE

    Seco, Raquel Irene; Schellart, Alma Neeltje Antonia; Gómez Valentín, Manuel; Tait, Simon

    2018-01-01

    Accurate predictions of sediment loads released by sewer overflow discharges are important for being able to provide protection to vulnerable receiving waters. These predictions are sensitive to the estimated sediment characteristics and on the site conditions of in-pipe deposit formation. Their application without a detailed analysis and understanding of the initial conditions under which in-sewer deposits were formed normally results in very poor estimations. In this study, in-sewer sedimen...

  11. Dynamics of rain-induced pollutographs of solubles in sewers.

    Science.gov (United States)

    Rutsch, M; Müller, I; Krebs, P

    2005-01-01

    When looking at acute receiving water impacts due to combined sewer overflows the characteristics of the background diurnal sewage flux variation may influence the peak loads from combined sewer overflows (CSO) and wastewater treatment plant (WWTP) effluent significantly. In this paper, effects on the dynamic compounds transported in the sewer, on CSO discharges and WWTP loading are evaluated by means of hydrodynamic simulations. The simulations are based on different scenarios for diurnal dry-weather flow variations induced by different infiltration rates.

  12. Using data from monitoring combined sewer overflows to assess, improve, and maintain combined sewer systems

    OpenAIRE

    Montserrat Royuela, Albert; Bosch, Ll.; Kiser, M.A.; Poch, Manuel; Corominas Tabares, Lluís

    2015-01-01

    Using low-cost sensors, data can be collected on the occurrence and duration of overflows in each combined sewer overflow (CSO) structure in a combined sewer system (CSS). The collection and analysis of real data can be used to assess, improve, and maintain CSSs in order to reduce the number and impact of overflows. The objective of this study was to develop a methodology to evaluate the performance of CSSs using low-cost monitoring. This methodology includes (1) assessing the capacity of a C...

  13. [Electrical storm].

    Science.gov (United States)

    Barnay, C; Taieb, J; Morice, R

    2007-11-01

    Electrical storm is defined as repeated occurrence of severe ventricular arrhythmias requiring multiple cardioversions, two or more or three or more following different studies. The clinical aspect can sometimes be made of multiple, self aggravating, life threatening accesses. There are three main clinical circumstances of occurrence: in patients equipped with intracardiac defibrillators, during the acute phase of myocardial infarction and in Brugada syndrome. 10 to 15% of patients with cardiac defibrillators are subject to electrical storms in a period of two years. The causative arrhythmia is most often ventricular tachycardia than ventricular fibrillation, especially in secondary prevention and if the initial arrhythmias justifying the device was a ventricular tachycardia. Precipitaing factors are present in one third of cases, mainly acute heart failure, ionic disorders and arrhythmogenic drugs. Predictive factors are age, left ventricular ejection fractionelectrical shock in 50% of cases, antitachycardi stimulation in 30% and in 20% by association of the two. Treatment, after elimination of inappropriate shocks, is mainly based on beta-blockers and amiodarone, class I antiarrhythmics, lidocaïne or bretylium in some cases, and sedation pushed to general anesthesia in some cases. Radio-frequency ablation and even heart transplantation have been proposed in extreme cases. Quinidine has been proved efficient in cases of Brugada syndrome.

  14. Following a drop of water from the cloud, throughout the sewer system, into the receiving water - Model predictive control of integrated sewer-wastewater treatment systems

    DEFF Research Database (Denmark)

    Mikkelsen, Peter Steen; Vezzaro, Luca; Sharma, Anitha Kumari

    This article presents selected examples of model-based prediction and control of integrated sewer-wastewater treatment systems, developed within the framework of the Storm- and Wastewater Informatics project (SWI). By exploiting all the available on-line information (e.g. radar based rainfall...... of pollutants discharged from treatment plants, etc.). The tools developed in the SWI project include (but are not limited to (i) rainfall nowcasting based on radar measurements, (ii) probabilistic flow forecasting based on data assimilation and stochastic models, (iii) prediction and optimization of wet......-weather performance of wastewater treatment plants, and (iv) integrated control of the different elements of the integrated wastewater systems. Full-scale testing of these tools in different catchment located in Denmark ensure that the developed tools can represent an important step forwards for on-line operation...

  15. Geomagnetic Storm Sudden Commencements

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Storm Sudden Commencements (ssc) 1868 to present: STORM1 and STORM2 Lists: (Some text here is taken from the International Association of Geomagnetism and Aeronomy...

  16. Recent findings on sinks for sulfide in gravity sewer networks

    DEFF Research Database (Denmark)

    Nielsen, Asbjørn Haaning; Hvitved-Jacobsen, Thorkild; Vollertsen, Jes

    2006-01-01

    summarizes this newly obtained knowledge and emphasizes important implications of the findings. Model simulations of the in-sewer processes important for the sulfur cycle showed that sulfide oxidation in the wetted biofilm is typically the most important sink for dissolved sulfide in gravity sewers. However...

  17. Radar Based Flow and Water Level Forecasting in Sewer Systems

    DEFF Research Database (Denmark)

    Thorndahl, Søren; Rasmussen, Michael R.; Grum, M.

    2009-01-01

    This paper describes the first radar based forecast of flow and/or water level in sewer systems in Denmark. The rainfall is successfully forecasted with a lead time of 1-2 hours, and flow/levels are forecasted an additional ½-1½ hours using models describing the behaviour of the sewer system. Bot...

  18. SEWER AND TANK FLUSHING FOR SEDIMENT, CORROSION AND POLLUTION CONTROL

    Science.gov (United States)

    This paper presents an overview of causes of sewer deterioration together with a discussion of control methods that can prevent or arrest this deterioration. In particular, the paper covers inline- and combined sewer overflow- (CSO) storage-tank-flushing systems for removal of se...

  19. Regulatory control analysis and design for sewer systems

    DEFF Research Database (Denmark)

    Mollerup, Ane Loft; Mikkelsen, Peter Steen; Thornberg, Dines

    2015-01-01

    A systematic methodology for regulatory control analysis and design is adapted for sewer system operation and evaluated. The main challenge with adapting the methodology is the handling of the stochastic and transient nature of the rainfall disturbances, inherent to sewer system operation...

  20. Oxidation and Precipitation of Sulfide in Sewer Networks

    DEFF Research Database (Denmark)

    Nielsen, A. H.

    risks and corrosion of concrete and metals. Most of the problems relate to the buildup of hydrogen sulfide in the atmosphere of sewer networks. In this respect, the processes of the sulfur cycle are of fundamental importance in ultimately determining the extent of such problems. This study focused...... calibrated and validated against field data. In the extension to the WATS model, sulfur transformations were described by six processes: 1. Sulfide production taking place in the biofilm and sediments covering the permanently wetted sewer walls; 2. Biological sulfide oxidation in the permanently wetted...... to the sewer atmosphere, potentially resulting in concrete corrosion. The extended WATS model represents a major improvement over previously developed models for prediction of sulfide buildup in sewer networks. Compared to such models, the major processes governing sulfide buildup in sewer networks...

  1. Modelling the viability of heat recovery from combined sewers.

    Science.gov (United States)

    Abdel-Aal, M; Smits, R; Mohamed, M; De Gussem, K; Schellart, A; Tait, S

    2014-01-01

    Modelling of wastewater temperatures along a sewer pipe using energy balance equations and assuming steady-state conditions was achieved. Modelling error was calculated, by comparing the predicted temperature drop to measured ones in three combined sewers, and was found to have an overall root mean squared error of 0.37 K. Downstream measured wastewater temperature was plotted against modelled values; their line gradients were found to be within the range of 0.9995-1.0012. The ultimate aim of the modelling is to assess the viability of recovering heat from sewer pipes. This is done by evaluating an appropriate location for a heat exchanger within a sewer network that can recover heat without impacting negatively on the downstream wastewater treatment plant (WWTP). Long sewers may prove to be more viable for heat recovery, as heat lost can be reclaimed before wastewater reaching the WWTP.

  2. Valuing information for sewer replacement decisions.

    Science.gov (United States)

    van Riel, Wouter; Langeveld, Jeroen; Herder, Paulien; Clemens, François

    Decision-making for sewer asset management is partially based on intuition and often lacks explicit argumentation, hampering decision transparency and reproducibility. This is not to be preferred in light of public accountability and cost-effectiveness. It is unknown to what extent each decision criterion is appreciated by decision-makers. Further insight into this relative importance improves understanding of decision-making of sewer system managers. As such, a digital questionnaire (response ratio 43%), containing pairwise comparisons between 10 relevant information sources, was sent to all 407 municipalities in the Netherlands to analyse the relative importance and assess whether a shared frame of reasoning is present. Thurstone's law of comparative judgment was used for analysis, combined with several consistency tests. Results show that camera inspections were valued highest, while pipe age was considered least important. The respondents were pretty consistent per individual and also showed consistency as a group. This indicated a common framework of reasoning among the group. The feedback of the group showed, however, the respondents found it difficult to make general comparisons without having a context. This indicates decision-making in practice is more likely to be steered by other mechanisms than purely combining information sources.

  3. Identifying the best locations to install flow control devices in sewer networks to enable in-sewer storage

    Science.gov (United States)

    Leitão, J. P.; Carbajal, J. P.; Rieckermann, J.; Simões, N. E.; Sá Marques, A.; de Sousa, L. M.

    2018-01-01

    The activation of available in-sewer storage volume has been suggested as a low-cost flood and combined sewer overflow mitigation measure. However, it is currently unknown what the attributes for suitable objective functions to identify the best location for flow control devices are and the impact of those attributes on the results. In this study, we present a novel location model and efficient algorithm to identify the best location(s) to install flow limiters. The model is a screening tool that does not require hydraulic simulations but rather considers steady state instead of simplistic static flow conditions. It also maximises in-sewer storage according to different reward functions that also considers the potential impact of flow control device failure. We demonstrate its usefulness on two real sewer networks, for which an in-sewer storage potential of approximately 2,000 m3 and 500 m3 was estimated with five flow control devices installed.

  4. Solar noise storms

    CERN Document Server

    Elgaroy, E O

    2013-01-01

    Solar Noise Storms examines the properties and features of solar noise storm phenomenon. The book also presents some theories that can be used to gain a better understanding of the phenomenon. The coverage of the text includes topics that cover the features and behavior of noise storms, such as the observable features of noise storms; the relationship between noise storms and the observable features on the sun; and ordered behavior of storm bursts in the time-frequency plane. The book also covers the spectrum, polarization, and directivity of noise storms. The text will be of great use to astr

  5. 40 CFR 35.935-16 - Sewer use ordinance and evaluation/rehabilitation program.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Sewer use ordinance and evaluation...-Clean Water Act § 35.935-16 Sewer use ordinance and evaluation/rehabilitation program. (a) The grantee... sewer use ordinance, and the grantee is complying with the sewer system evaluation and rehabilitation...

  6. Innovative use of lamella clarifiers for central stormwater treatment in separate sewer systems.

    Science.gov (United States)

    Weiss, Gebhard

    2014-01-01

    Lamella settlers have been used in the past few years for the sedimentation of particles in wastewater and stormwater applications. A new and very innovative approach for the treatment of stormwater flows is proposed which extends the portfolio of solutions beyond traditional settling tanks. Surface runoff is stored in a sewer or a basin and finally treated in a small but continuously operated lamella clarifier. The low throughput flow will yield good treatment efficiency at a small footprint. The possibilities of using existing storage volume in a storm sewer, as well as the structural flexibility of the arrangement are decisive benefits. As a large operational advantage, the lamellae may be cleaned mechanically, e.g. by pivoting under water. Finally, the flow and the sludge which will be sent to the downstream treatment plant will be minimized. A new comparative simulation method is proposed in order to assess an equivalent degree of stormwater treatment, either by achieving an equal annual volume of treated stormwater or, more directly, an equal amount of spilled pollutant load. The new solution is compared with a traditional settling tank according to current German design rules. Additionally, a case study from a real installation will be presented.

  7. Predicting combined sewer overflows chamber depth using artificial neural networks with rainfall radar data.

    Science.gov (United States)

    Mounce, S R; Shepherd, W; Sailor, G; Shucksmith, J; Saul, A J

    2014-01-01

    Combined sewer overflows (CSOs) represent a common feature in combined urban drainage systems and are used to discharge excess water to the environment during heavy storms. To better understand the performance of CSOs, the UK water industry has installed a large number of monitoring systems that provide data for these assets. This paper presents research into the prediction of the hydraulic performance of CSOs using artificial neural networks (ANN) as an alternative to hydraulic models. Previous work has explored using an ANN model for the prediction of chamber depth using time series for depth and rain gauge data. Rainfall intensity data that can be provided by rainfall radar devices can be used to improve on this approach. Results are presented using real data from a CSO for a catchment in the North of England, UK. An ANN model trained with the pseudo-inverse rule was shown to be capable of predicting CSO depth with less than 5% error for predictions more than 1 hour ahead for unseen data. Such predictive approaches are important to the future management of combined sewer systems.

  8. A dynamic ventilation model for gravity sewer networks.

    Science.gov (United States)

    Wang, Y C; Nobi, N; Nguyen, T; Vorreiter, L

    2012-01-01

    To implement any effective odour and corrosion control technology in the sewer network, it is imperative that the airflow through gravity sewer airspaces be quantified. This paper presents a full dynamic airflow model for gravity sewer systems. The model, which is developed using the finite element method, is a compressible air transport model. The model has been applied to the North Head Sewerage Ocean Outfall System (NSOOS) and calibrated using the air pressure and airflow data collected during October 2008. Although the calibration is focused on forced ventilation, the model can be applied to natural ventilation as well.

  9. Numerical Modelling Approaches for Sediment Transport in Sewer Systems

    DEFF Research Database (Denmark)

    Mark, Ole

    A study of the sediment transport processes in sewers has been carried out. Based on this study a mathematical modelling system has been developed to describe the transport processes of sediments and dissolved matter in sewer systems. The modelling system consists of three sub-models which...... constitute the basic modelling system necessary to give a discription of the most dominant physical transport processes concerning particles and dissolved matter in sewer systems: A surface model. An advection-dispersion model. A sediment transport model....

  10. Characteristics of the overflow pollution of storm drains with inappropriate sewage entry.

    Science.gov (United States)

    Yin, Hailong; Lu, Yi; Xu, Zuxin; Li, Huaizheng; Schwegler, Benedict R

    2017-02-01

    To probe the overflow pollution of separate storm drains with inappropriate sewage entries, in terms of the relationship between sewage entries and the corresponding dry-weather and wet-weather overflow, the monitoring activities were conducted in a storm drainage system in the Shanghai downtown area (374 ha). In this study site, samples from inappropriately entered dry-weather sewage and the overflow due to storm pumps operation on dry-weather and wet-weather days were collected and then monitored for six water quality constituents. It was found that overflow concentrations of dry-weather period could be higher than those of wet-weather period; under wet-weather period, the overflow concentrations of storm drains were close to or even higher than that of combined sewers. Relatively strong first flush mostly occurred under heavy rain that satisfied critical rainfall amount, maximum rainfall intensity, and maximum pumping discharge, while almost no first flush effect or only weak first flush effect was found for the other rainfall events. Such phenomenon was attributed to lower in-line pipe storage as compared to that of the combined sewers, and serious sediment accumulation within the storm pipes due to sewage entry. For this kind of system, treating a continuous overflow rate is a better strategy than treating the maximum amount of early part of the overflow. Correcting the key inappropriate sewage entries into storm drains should also be focused.

  11. Sandia National Laboratories, California sewer system management plan.

    Energy Technology Data Exchange (ETDEWEB)

    Holland, Robert C.

    2010-02-01

    A Sewer System Management Plan (SSMP) is required by the State Water Resources Control Board (SWRCB) Order No. 2006-0003-DWQ Statewide General Waste Discharge Requirements (WDR) for Sanitary Sewer Systems (General Permit). DOE, National Nuclear Security Administration (NNSA), Sandia Site Office has filed a Notice of Intent to be covered under this General Permit. The General Permit requires a proactive approach to reduce the number and frequency of sanitary sewer overflows (SSOs) within the State. SSMPs must include provisions to provide proper and efficient management, operation, and maintenance of sanitary sewer systems and must contain a spill response plan. Elements of this Plan are under development in accordance with the SWRCB's schedule.

  12. New Findings in Hydrogen Sulfide Related Corrosion of Concrete Sewers

    DEFF Research Database (Denmark)

    Nielsen, Asbjørn Haaning; Jensen, Henriette Stokbro; Hvitved-Jacobsen, Thorkild

    2009-01-01

    This paper summarizes major findings of a long-term study of hydrogen sulfide gas (H2S) adsorption and oxidation on concrete and plastic sewer pipe surfaces. The processes have been studied using a pilot-scale setup designed to replicate conditions in a gravity sewer located downstream of a force...... main. H2S related concrete corrosion and odor is often observed at such locations. The experiments showed that the rate of H2S oxidation was significantly faster on concrete pipe surfaces than on plastic pipe surfaces. Steady state calculations based on the kinetic data demonstrated that the gas phase...... H2S concentration in concrete sewers would typically amount to a few percent of the equilibrium concentration calculated from Henrys law. In plastic pipe sewers, significantly higher concentrations were predicted because of the slower adsorption and oxidation kinetics on these surfaces. Finally...

  13. Colorado River Sewer System Joint Venture to Upgrade Wastewater System

    Science.gov (United States)

    SAN FRANCISCO -Today, the Colorado River Sewer System Joint Venture, located in Parker, Ariz. entered into an agreement with the EPA to upgrade their wastewater treatment system to meet stringent water quality standards. The cost of the upgrade is ap

  14. Urban runoff and combined sewer overflow. [Wastewater treatment

    Energy Technology Data Exchange (ETDEWEB)

    Moffa, P.E. (Calocerinos and Spina, Liverpool, NY); Freedman, S.D.; Owens, E.M.; Field, R.; Cibik, C.

    1982-06-01

    The control, treatment and management of urban runoff and sewer overflow are reviewed. Simplified modeling and monitoring techniques are used to characterize urban runoff and to assess control alternatives. (KRM)

  15. Development of Sediment Deposition Height Capacity Equation in Sewer Networks

    Science.gov (United States)

    Song, Yangho; Jo, Deokjun; Lee, Jungho

    2017-04-01

    Sediment characteristics and transport processes in sewers are markedly different from river. There is a wide range of particle densities and smaller particle size variation in sewers. Sediment supply and the available erodible material are more limited in sewers, and the diverse hydraulic characteristics in sewer systems are more unsteady. Prevention of sewer sediment accumulation, which can cause major sewer operational problems, is imperative and has been an immense concern for engineers. The effects of sediment formation in sewer systems, an appropriate sediment transport modelling with the ability to determine the location and depth of sediment deposit is needed. It is necessary to design efficiently considering the transfer and settling phenomena of the sediment coming into the sewer systems. During transport in the sewer, the minimum shear flow velocity and possible shear stress at which the sediment is transported smoothly. However, the interaction of sediment and fluid within the sewer systems has been very complex and the rigorous theoretical handling of this problem has not been developed. It is derived from the empirical values obtained from the river bed. The basic theory that particles float is based on the balance between sedimentation of particles by gravity and turbulent diffusion of fluids. There are many variables related. Representative parameters include complex phenomena due to collisions between particles, particles and fluids, and interactions between particles and tube walls. In general, the main parameters that form the boundary between the main transport and sediment are particle size, density, volume fraction, pipe diameter and gravity. As the particle size and volume concentration increase, the minimum feed rate increases and the same tendency is observed for the change of the capillary diameter. Based on this tendency, this study has developed a sediment deposition height capacity formula to take into consideration the sewer discharge

  16. SEWER NETWORK DISCHARGE OPTIMIZATION USING THE DYNAMIC PROGRAMMING

    Directory of Open Access Journals (Sweden)

    Viorel MINZU

    2015-12-01

    Full Text Available It is necessary to adopt an optimal control that allows an efficient usage of the existing sewer networks, in order to avoid the building of new retention facilities. The main objective of the control action is to minimize the overflow volume of a sewer network. This paper proposes a method to apply a solution obtained by discrete dynamic programming through a realistic closed loop system.

  17. NCDC Storm Events Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Storm Data is provided by the National Weather Service (NWS) and contain statistics on personal injuries and damage estimates. Storm Data covers the United States of...

  18. Factors affecting economies of scale in combined sewer systems.

    Science.gov (United States)

    Maurer, Max; Wolfram, Martin; Anja, Herlyn

    2010-01-01

    A generic model is introduced that represents the combined sewer infrastructure of a settlement quantitatively. A catchment area module first calculates the length and size distribution of the required sewer pipes on the basis of rain patterns, housing densities and area size. These results are fed into the sewer-cost module in order to estimate the combined sewer costs of the entire catchment area. A detailed analysis of the relevant input parameters for Swiss settlements is used to identify the influence of size on costs. The simulation results confirm that an economy of scale exists for combined sewer systems. This is the result of two main opposing cost factors: (i) increased construction costs for larger sewer systems due to larger pipes and increased rain runoff in larger settlements, and (ii) lower costs due to higher population and building densities in larger towns. In Switzerland, the more or less organically grown settlement structures and limited land availability emphasise the second factor to show an apparent economy of scale. This modelling approach proved to be a powerful tool for understanding the underlying factors affecting the cost structure for water infrastructures.

  19. Using data from monitoring combined sewer overflows to assess, improve, and maintain combined sewer systems.

    Science.gov (United States)

    Montserrat, A; Bosch, Ll; Kiser, M A; Poch, M; Corominas, Ll

    2015-02-01

    Using low-cost sensors, data can be collected on the occurrence and duration of overflows in each combined sewer overflow (CSO) structure in a combined sewer system (CSS). The collection and analysis of real data can be used to assess, improve, and maintain CSSs in order to reduce the number and impact of overflows. The objective of this study was to develop a methodology to evaluate the performance of CSSs using low-cost monitoring. This methodology includes (1) assessing the capacity of a CSS using overflow duration and rain volume data, (2) characterizing the performance of CSO structures with statistics, (3) evaluating the compliance of a CSS with government guidelines, and (4) generating decision tree models to provide support to managers for making decisions about system maintenance. The methodology is demonstrated with a case study of a CSS in La Garriga, Spain. The rain volume breaking point from which CSO structures started to overflow ranged from 0.6 mm to 2.8 mm. The structures with the best and worst performance in terms of overflow (overflow probability, order, duration and CSO ranking) were characterized. Most of the obtained decision trees to predict overflows from rain data had accuracies ranging from 70% to 83%. The results obtained from the proposed methodology can greatly support managers and engineers dealing with real-world problems, improvements, and maintenance of CSSs. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. On-line monitoring of methane in sewer air.

    Science.gov (United States)

    Liu, Yiwen; Sharma, Keshab R; Murthy, Sudhir; Johnson, Ian; Evans, Ted; Yuan, Zhiguo

    2014-10-16

    Methane is a highly potent greenhouse gas and contributes significantly to climate change. Recent studies have shown significant methane production in sewers. The studies conducted so far have relied on manual sampling followed by off-line laboratory-based chromatography analysis. These methods are labor-intensive when measuring methane emissions from a large number of sewers, and do not capture the dynamic variations in methane production. In this study, we investigated the suitability of infrared spectroscopy-based on-line methane sensors for measuring methane in humid and condensing sewer air. Two such sensors were comprehensively tested in the laboratory. Both sensors displayed high linearity (R(2) > 0.999), with a detection limit of 0.023% and 0.110% by volume, respectively. Both sensors were robust against ambient temperature variations in the range of 5 to 35°C. While one sensor was robust against humidity variations, the other was found to be significantly affected by humidity. However, the problem was solved by equipping the sensor with a heating unit to increase the sensor surface temperature to 35°C. Field studies at three sites confirmed the performance and accuracy of the sensors when applied to actual sewer conditions, and revealed substantial and highly dynamic methane concentrations in sewer air.

  1. Optimal Design of Gravitational Sewer Networks with General Cellular Automata

    Directory of Open Access Journals (Sweden)

    Mohammad Hadi Afshar

    2014-05-01

    Full Text Available In this paper, a Cellular Automata method is applied for the optimal design of sewer networks. The solution of sewer network optimization problems requires the determination of pipe diameters and average pipe cover depths, minimizing the total cost of the sewer network subject to operational constraints. In this paper, the network nodes and upstream and downstream pipe cover depths are considered as CA cells and cell states, respectively, and the links around each cell are taken into account as neighborhood. The proposed method is a general and flexible method for the optimization of sewer networks as it can be used to optimally design both gravity and pumped network due to the use of pipe nodal cover depths as the decision variables. The proposed method is tested against two  gravitational sewer networks and the  comparison of results with other methods such as  Genetic algorithm, Cellular Automata, Ant Colony Optimization Algorithm and Particle Swarm Optimization show the efficiency and effectiveness of the proposed method.

  2. Green Infrastructure Simulation and Optimization to Achieve Combined Sewer Overflow Reductions in Philadelphia's Mill Creek Sewershed

    Science.gov (United States)

    Cohen, J. S.; McGarity, A. E.

    2017-12-01

    The ability for mass deployment of green stormwater infrastructure (GSI) to intercept significant amounts of urban runoff has the potential to reduce the frequency of a city's combined sewer overflows (CSOs). This study was performed to aid in the Overbrook Environmental Education Center's vision of applying this concept to create a Green Commercial Corridor in Philadelphia's Overbrook Neighborhood, which lies in the Mill Creek Sewershed. In an attempt to further implement physical and social reality into previous work using simulation-optimization techniques to produce GSI deployment strategies (McGarity, et al., 2016), this study's models incorporated land use types and a specific neighborhood in the sewershed. The low impact development (LID) feature in EPA's Storm Water Management Model (SWMM) was used to simulate various geographic configurations of GSI in Overbrook. The results from these simulations were used to obtain formulas describing the annual CSO reduction in the sewershed based on the deployed GSI practices. These non-linear hydrologic response formulas were then implemented into the Storm Water Investment Strategy Evaluation (StormWISE) model (McGarity, 2012), a constrained optimization model used to develop optimal stormwater management practices on the watershed scale. By saturating the avenue with GSI, not only will CSOs from the sewershed into the Schuylkill River be reduced, but ancillary social and economic benefits of GSI will also be achieved. The effectiveness of these ancillary benefits changes based on the type of GSI practice and the type of land use in which the GSI is implemented. Thus, the simulation and optimization processes were repeated while delimiting GSI deployment by land use (residential, commercial, industrial, and transportation). The results give a GSI deployment strategy that achieves desired annual CSO reductions at a minimum cost based on the locations of tree trenches, rain gardens, and rain barrels in specified land

  3. Output-feedback control of combined sewer networks through receding horizon control with moving horizon estimation

    OpenAIRE

    Joseph-Duran, Bernat; Ocampo-Martinez, Carlos; Cembrano, Gabriela

    2015-01-01

    An output-feedback control strategy for pollution mitigation in combined sewer networks is presented. The proposed strategy provides means to apply model-based predictive control to large-scale sewer networks, in-spite of the lack of measurements at most of the network sewers. In previous works, the authors presented a hybrid linear control-oriented model for sewer networks together with the formulation of Optimal Control Problems (OCP) and State Estimation Problems (SEP). By iteratively solv...

  4. Impacts on sewer performance due to changes to inputs in domestic wastewater

    OpenAIRE

    Mattsson, Jonathan

    2015-01-01

    The impacts of changes in domestic wastewater inputs on sewer performance have been debated since the dawn of the great sewer construction movement in the 1850s. Nowadays, typical household wastewater that enters sewers can generally be divided into streams from the WC, shower and/or bathtub, kitchen sink, washing machine and dishwasher. Changes in thecomposition of domestic wastewater entering a sewer will depend on inter alia the properties of the appliances used in the households and house...

  5. SAFL Baffle retrofit for suspended sediment removal in storm sewer sumps.

    Science.gov (United States)

    Howard, Adam; Mohseni, Omid; Gulliver, John; Stefan, Heinz

    2011-11-15

    Standard sumps (manholes) provide a location for pipe junctions and maintenance access in stormwater drainage systems. Standard sumps can also remove sand and silt particles from stormwater, but have a high propensity for washout of the collected sediment. With appropriate maintenance these sumps may qualify as a stormwater best management practice (BMP) device for the removal of suspended sediment from stormwater runoff. To decrease the maintenance frequency and prevent standard sumps from becoming a source of suspended sediment under high flow conditions, a porous baffle, named the SAFL Baffle, has been designed and tested as a retrofit to the sump. Multiple configurations with varying percent open area and different angles of attack were evaluated in scale models. An optimum configuration was then constructed at the prototype scale and evaluated for both removal efficiency and washout. Results obtained with the retrofit indicate that with the right baffle dimensions and porosity, sediment washout from the sump at high flow rates can be almost eliminated, and removal efficiency can be significantly increased at low flow rates. Removal efficiency and washout functions have been developed for standard sumps retrofitted with the SAFL Baffle. The results of this research provide a new, versatile stormwater treatment device and implemented new washout and removal efficiency testing procedures that will improve research and development of stormwater treatment devices. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. EPA Region 2 NPDES Municipal Separate Storm Sewer System Outfalls (MS4) GIS Layer

    Data.gov (United States)

    U.S. Environmental Protection Agency — This ArcGIS 10.3 point feature class contains identification, location, and outfall attributes including outfall size and receiving water body, and class information...

  7. An effective and comprehensive model for optimal rehabilitation of separate sanitary sewer systems.

    Science.gov (United States)

    Diogo, António Freire; Barros, Luís Tiago; Santos, Joana; Temido, Jorge Santos

    2018-01-15

    In the field of rehabilitation of separate sanitary sewer systems, a large number of technical, environmental, and economic aspects are often relevant in the decision-making process, which may be modelled as a multi-objective optimization problem. Examples are those related with the operation and assessment of networks, optimization of structural, hydraulic, sanitary, and environmental performance, rehabilitation programmes, and execution works. In particular, the cost of investment, operation and maintenance needed to reduce or eliminate Infiltration from the underground water table and Inflows of storm water surface runoff (I/I) using rehabilitation techniques or related methods can be significantly lower than the cost of transporting and treating these flows throughout the lifespan of the systems or period studied. This paper presents a comprehensive I/I cost-benefit approach for rehabilitation that explicitly considers all elements of the systems and shows how the approximation is incorporated as an objective function in a general evolutionary multi-objective optimization model. It takes into account network performance and wastewater treatment costs, average values of several input variables, and rates that can reflect the adoption of different predictable or limiting scenarios. The approach can be used as a practical and fast tool to support decision-making in sewer network rehabilitation in any phase of a project. The fundamental aspects, modelling, implementation details and preliminary results of a two-objective optimization rehabilitation model using a genetic algorithm, with a second objective function related to the structural condition of the network and the service failure risk, are presented. The basic approach is applied to three real world cases studies of sanitary sewerage systems in Coimbra and the results show the simplicity, suitability, effectiveness, and usefulness of the approximation implemented and of the objective function proposed

  8. A methodological approach to designing sewer system control

    DEFF Research Database (Denmark)

    Mollerup, Ane Loft

    for this thesis was therefore the wish for a methodological approach to sewer system control design. Using a case study the following research hypothesis was tested in this thesis: Using classical and modern control theory, a methodological approach can be derived for designing sewer system control. This can aid....... This was not unexpected, since the true potential of having optimisation arises, when a system has many control loops with limit-ing constraints and/or changing prioritisation between them. The results showed that for small sewer systems, where the complexity is limited, it is not necessarily the best option to implement...... generate control systems of the future that are more robust, more structured, have a better performance and are easi-er to maintain....

  9. Tree root intrusion in sewer systems: A review of extent and costs

    Science.gov (United States)

    T.B. Randrup; E.G. McPherson; L.R. Costello

    2001-01-01

    Interference between trees and sewer systems is likely to occur in old systems and in cracked pipes. Factors that contribute to damage include old pipes with joints, shallow pipes, small-dimension pipes, and fast-growing tree species. Because roots are reported to cause >50% of all sewer blockages, costs associated with root removal from sewers is substantial. In...

  10. A statistical approach to guide the management of the anterior part of the sewer system

    NARCIS (Netherlands)

    Post, J.A.B.

    2016-01-01

    The anterior part of the sewer system consists of a system of gully pots and lateral (house) connections that drain to main sewers. The total length of lateral house connections can be similar to the total length of the sewers they drain to. In addition, there are 7 million gully pots with

  11. Evidence of a sewer vapor transport pathway at the USEPA vapor intrusion research duplex

    Science.gov (United States)

    The role of sewer lines as preferential pathways for vapor intrusion is poorly understood. Although the importance of sewer lines for volatile organic compound (VOC) transport has been documented at a small number of sites with vapor intrusion, sewer lines are not routinely sampl...

  12. Ventilation in Sewers Quantified by Measurements of CO2

    DEFF Research Database (Denmark)

    Fuglsang, Emil Dietz; Vollertsen, Jes; Nielsen, Asbjørn Haaning

    2012-01-01

    Understanding and quantifying ventilation in sewer systems is a prerequisite to predict transport of odorous and corrosive gasses within the system as well as their interaction with the urban atmosphere. This paper studies ventilation in sewer systems quantified by measurements of the natural...... occurring compound CO2. Most often Danish wastewater is supersaturated with CO2 and hence a potential for stripping is present. A novel model was built based on the kinetics behind the stripping process. It was applied to simulate ventilation rates from field measurements of wastewater temperature, p...

  13. High prevalence of Leptospira spp. in sewer rats (Rattus norvegicus)

    DEFF Research Database (Denmark)

    Krøjgaard, L H; Villumsen, S; Markussen, M D K

    2009-01-01

    Earlier studies on the ecology of leptospirosis in temperate regions focused mainly on free-ranging rats in rural areas. Here we report on the occurrence of Leptospira spp. in Rattus norvegicus living in sewers in a suburban area in Copenhagen, Denmark. In 2006-2007, about 30 rats were captured...... in sewers at each of six different locations. Rat kidneys were screened by PCR for pathogenic Leptospira spp. In one location no infected rats were found, whereas the prevalence in the remaining five locations ranged between 48% and 89%. Micro-agglutination tests showed that serogroup Pomona, Sejroe...

  14. Air Flows in Gravity Sewers - Determination of Wastewater Drag Coefficient

    DEFF Research Database (Denmark)

    Bentzen, Thomas Ruby; Østertoft, Kristian; Vollertsen, Jes

    2016-01-01

    Several experiments have been conducted in order to improve the understanding of the wastewater drag and the wall frictional force acting on the headspace air in gravity sewers. The aim of the study is to improve the data basis for a numerical model of natural sewer ventilation. The results...... of the study shows that by integrating the top/side wall shear stresses the log-law models for the air velocity distribution along the unwetted perimeter resulted in a good agreement with the friction forces calculated by use of the Colebrook-White formula for hydraulic smooth pipes. Secondly, the water...

  15. Assessment of the contribution of sewer deposits to suspended solids loads in combined sewer systems during rain events.

    Science.gov (United States)

    Hannouche, A; Chebbo, G; Joannis, C

    2014-04-01

    Within the French observatories network SOERE "URBIS," databases of continuous turbidity measurements accumulating hundreds of events and many dry weather days are available for two sites with different features (Clichy in Paris and Ecully in Lyon). These measurements, converted into total suspended solids (TSS) concentration using TSS-turbidity relationships and combined with a model of runoff event mean concentration, enable the assessment of the contribution of sewer deposits to wet weather TSS loads observed at the outlet of the two watersheds. Results show that the contribution of sewer deposits to wet weather suspended solid's discharges is important but variable (between 20 and 80 % of the mass at the outlet depending on the event), including a site allegedly free of (coarse) sewer deposits. The uncertainties associated to these results are assessed too.

  16. Overview of the ARkStorm scenario

    Science.gov (United States)

    Porter, Keith; Wein, Anne; Alpers, Charles N.; Baez, Allan; Barnard, Patrick L.; Carter, James; Corsi, Alessandra; Costner, James; Cox, Dale; Das, Tapash; Dettinger, Mike; Done, James; Eadie, Charles; Eymann, Marcia; Ferris, Justin; Gunturi, Prasad; Hughes, Mimi; Jarrett, Robert; Johnson, Laurie; Le-Griffin, Hanh Dam; Mitchell, David; Morman, Suzette; Neiman, Paul; Olsen, Anna; Perry, Suzanne; Plumlee, Geoffrey; Ralph, Martin; Reynolds, David; Rose, Adam; Schaefer, Kathleen; Serakos, Julie; Siembieda, William; Stock, Jonathan; Strong, David; Wing, Ian Sue; Tang, Alex; Thomas, Pete; Topping, Ken; Wills, Chris; Jones, Lucile

    2011-01-01

    coastal communities. Windspeeds in some places reach 125 miles per hour, hurricane-force winds. Across wider areas of the state, winds reach 60 miles per hour. Hundreds of landslides damage roads, highways, and homes. Property damage exceeds $300 billion, most from flooding. Demand surge (an increase in labor rates and other repair costs after major natural disasters) could increase property losses by 20 percent. Agricultural losses and other costs to repair lifelines, dewater (drain) flooded islands, and repair damage from landslides, brings the total direct property loss to nearly $400 billion, of which $20 to $30 billion would be recoverable through public and commercial insurance. Power, water, sewer, and other lifelines experience damage that takes weeks or months to restore. Flooding evacuation could involve 1.5 million residents in the inland region and delta counties. Business interruption costs reach $325 billion in addition to the $400 property repair costs, meaning that an ARkStorm could cost on the order of $725 billion, which is nearly 3 times the loss deemed to be realistic by the ShakeOut authors for a severe southern California earthquake, an event with roughly the same annual occurrence probability. The ARkStorm has several public policy implications: (1) An ARkStorm raises serious questions about the ability of existing federal, state, and local disaster planning to handle a disaster of this magnitude. (2) A core policy issue raised is whether to pay now to mitigate, or pay a lot more later for recovery. (3) Innovative financing solutions are likely to be needed to avoid fiscal crisis and adequately fund response and recovery costs from a similar, real, disaster. (4) Responders and government managers at all levels could be encouraged to conduct risk assessments, and devise the full spectrum of exercises, to exercise ability of their plans to address a similar event. (5) ARkStorm can be a reference point for application of Federal Emergency Ma

  17. Nippon Storm Study design

    Directory of Open Access Journals (Sweden)

    Takashi Kurita

    2012-10-01

    Full Text Available An understanding of the clinical aspects of electrical storm (E-storms in patients with implantable cardiac shock devices (ICSDs: ICDs or cardiac resynchronization therapy with defibrillator [CRT-D] may provide important information for clinical management of patients with ICSDs. The Nippon Storm Study was organized by the Japanese Heart Rhythm Society (JHRS and Japanese Society of Electrocardiology and was designed to prospectively collect a variety of data from patients with ICSDs, with a focus on the incidence of E-storms and clinical conditions for the occurrence of an E-storm. Forty main ICSD centers in Japan are participating in the present study. From 2002, the JHRS began to collect ICSD patient data using website registration (termed Japanese cardiac defibrillator therapy registration, or JCDTR. This investigation aims to collect data on and investigate the general parameters of patients with ICSDs, such as clinical backgrounds of the patients, purposes of implantation, complications during the implantation procedure, and incidence of appropriate and inappropriate therapies from the ICSD. The Nippon Storm Study was planned as a sub-study of the JCDTR with focus on E-storms. We aim to achieve registration of more than 1000 ICSD patients and complete follow-up data collection, with the assumption of a 5–10% incidence of E-storms during the 2-year follow-up.

  18. Assessing storm erosion hazards

    NARCIS (Netherlands)

    Ranasinghe, Ranasinghe W M R J B; Callaghan, D.; Ciavola, Paolo; Coco, Giovanni

    2017-01-01

    The storm erosion hazard on coasts is usually expressed as an erosion volume and/or associated episodic coastline retreat. The accurate assessment of present-day and future storm erosion volumes is a key task for coastal zone managers, planners and engineers. There are four main approaches that can

  19. Deterministic Versus Stochastic Interpretation of Continuously Monitored Sewer Systems

    DEFF Research Database (Denmark)

    Harremoës, Poul; Carstensen, Niels Jacob

    1994-01-01

    An analysis has been made of the uncertainty of input parameters to deterministic models for sewer systems. The analysis reveals a very significant uncertainty, which can be decreased, but not eliminated and has to be considered for engineering application. Stochastic models have a potential for ...

  20. HIGH-RATE DISINFECTION TECHNIQUES FOR COMBIND SEWER OVERFLOW

    Science.gov (United States)

    This paper presents high-rate disinfection technologies for combined sewer overflow (CSO). The high-rate disinfection technologies of interest are: chlorination/dechlorination, ultraviolet light irradiation (UV), chlorine dioxide (ClO2 ), ozone (O3), peracetic acid (CH3COOOH )...

  1. NORTH PORTAL - SANITARY SEWER CALCULATION - CHANGE HOUSE FACILITY No.5008

    International Nuclear Information System (INIS)

    Blackstone, R.

    1996-01-01

    The purpose of this design calculation is to determine the demand on the waste system and to size the three main sanitary sewer lines serving the Change House Facility No.5008, in accordance with the Uniform Plumbing Code (Section 4.4.1) and U.S. Department of Energy Order 6430.1A-1540 (Section 4.4.2)

  2. A comparison of sewer reticulation system design standards gravity ...

    African Journals Online (AJOL)

    Thirdly Botswana being a dry country does not always have the water supply available and only some households have a house connection which provides enough water to flush a gravity sewer. Coupled to this is the low housing density and generally flat landscape in rural Botswana that means the conventional gravity ...

  3. Sanitary sewer rehabilitation at Lawrence Livermore National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Vellinger, R. J.; Burton, R.; Fritschy, B.

    1995-04-01

    The objectives of this paper are the following: to present LLNL`s collection system and innovative approach to sanitary sewer rehabilitation; share issues identified and lessons learned from over four (4) years of rehabilitation work; and discuss proposed system standards for ongoing maintenance and repair activities.

  4. Damage estimation of sewer pipe using subtitles of CCTV inspection video

    Science.gov (United States)

    Park, Kitae; Kim, Byeongcheol; Kim, Taeheon; Seo, Dongwoo

    2017-04-01

    Recent frequent occurrence of urban sinkhole serves as a momentum of the periodic inspection of sewer pipelines. Sewer inspection using a CCTV device needs a lot of time and efforts. Many of previous studies which reduce the laborious tasks are mainly interested in the developments of image processing S/W and exploring H/W. And there has been no attempt to find meaningful information from the existing CCTV images stored by the sewer maintenance manager. This study adopts a cross-correlation based image processing method and extracts sewer inspection device's location data from CCTV images. As a result of the analysis of location-time relation, it show strong correlation between device stand time and the sewer damages. In case of using this method to investigate sewer inspection CCTV images, it will save the investigator's efforts and improve sewer maintenance efficiency and reliability.

  5. Modeling Sulfides, pH and Hydrogen Sulfide Gas in the Sewers of San Francisco

    DEFF Research Database (Denmark)

    Vollertsen, Jes; Revilla, Nohemy; Hvitved-Jacobsen, Thorkild

    2015-01-01

    An extensive measuring campaign targeted on sewer odor problems was undertaken in San Francisco. It was assessed whether a conceptual sewer process model could reproduce the measured concentrations of total sulfide in the wastewater and H2S gas in the sewer atmosphere, and to which degree...... such simulations have potential for further improving odor and sulfide management. The campaign covered measurement of wastewater sulfide by grab sampling and diurnal sampling, and H2S gas in the sewer atmosphere was logged. The tested model was based on the Wastewater Aerobic/Anaerobic Transformations in Sewers...... (WATS) sewer process concept, which never had been calibrated to such an extensive dataset. The study showed that the model was capable of reproducing the general levels of wastewater sulfide, wastewater pH, and sewer H2S gas. It could also reproduce the general variability of these parameters, albeit...

  6. Contributions of wastewater, runoff and sewer deposit erosion to wet weather pollutant loads in combined sewer systems.

    Science.gov (United States)

    Gasperi, J; Gromaire, M C; Kafi, M; Moilleron, R; Chebbo, G

    2010-12-01

    An observatory of urban pollutants was created in Paris for the purpose of assessing the dynamics of wastewater and wet weather flow (WW and WWF) pollutant loads within combined sewers. This observatory is composed of six urban catchments, covering land areas ranging in size from 42 ha to 2581 ha. For a wide array of parameters including total suspended solids (TSS), chemical and biochemical oxygen demand (COD and BOD(5)), total organic carbon (TOC), total Kjeldahl nitrogen (TKN), heavy metals (Cu and Zn) and polycyclic aromatic hydrocarbons (PAHs), this article is intended to evaluate the contributions of wastewater, runoff and in-sewer processes to WWF pollutant loads through the use of an entry-exit mass balance approach. To achieve this objective, a total of 16 rain events were sampled on these sites between May 2003 and February 2006. This study has confirmed that at the considered catchment scale (i.e. from 42 ha to 2581 ha) the production and transfer processes associated with WWF pollutant loads do not vary with basin scale. Entry-exit chemical mass balances over all catchments and for a large number of rain events indicate that wastewater constitutes the main source of organic and nitrogenous pollution, while runoff is the predominant source of Zn. For Cu, PAHs and TSS, the calculation underscores the major role played by in-sewer processes, specifically by sediment erosion, as a source of WWF pollution. A significant loss of dissolved metals was also observed during their transfer within the sewer network, likely as a consequence of the adsorption of dissolved metals on TSS and/or on sewer deposits. Moreover, the nature of eroded particles was examined and compared to the various sewer deposits. This comparison has highlighted that such particles exhibit similar organic and PAH contents to those measured in the organic layer, thus suggesting that the deposit eroded during a wet weather period is organic and of a nature comparable to the organic layer

  7. Storm Data Publication

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — 'Storm Data and Unusual Weather Phenomena' is a monthly publication containing a chronological listing, by state, of hurricanes, tornadoes, thunderstorms, hail,...

  8. Potential of turbidity monitoring for real time control of pollutant discharge in sewers during rainfall events.

    Science.gov (United States)

    Lacour, C; Joannis, C; Gromaire, M-C; Chebbo, G

    2009-01-01

    Turbidity sensors can be used to continuously monitor the evolution of pollutant mass discharge. For two sites within the Paris combined sewer system, continuous turbidity, conductivity and flow data were recorded at one-minute time intervals over a one-year period. This paper is intended to highlight the variability in turbidity dynamics during wet weather. For each storm event, turbidity response aspects were analysed through different classifications. The correlation between classification and common parameters, such as the antecedent dry weather period, total event volume per impervious hectare and both the mean and maximum hydraulic flow for each event, was also studied. Moreover, the dynamics of flow and turbidity signals were compared at the event scale. No simple relation between turbidity responses, hydraulic flow dynamics and the chosen parameters was derived from this effort. Knowledge of turbidity dynamics could therefore potentially improve wet weather management, especially when using pollution-based real-time control (P-RTC) since turbidity contains information not included in hydraulic flow dynamics and not readily predictable from such dynamics.

  9. Storm surge climatology report

    OpenAIRE

    Horsburgh, Kevin; Williams, Joanne; Cussack, Caroline

    2017-01-01

    Any increase in flood frequency or severity due to sea level rise or changes in storminess would adversely impact society. It is crucial to understand the physical drivers of extreme storm surges to have confidence in the datasets used for extreme sea level statistics. We will refine and improve methods to the estimation of extreme sea levels around Europe and more widely. We will do so by developing a comprehensive world picture of storm surge distribution (including extremes) for both tropi...

  10. Application of a leakage model to assess exfiltration from sewers.

    Science.gov (United States)

    Karpf, C; Krebs, P

    2005-01-01

    The exfiltration of wastewater from sewer systems in urban areas causes a deterioration of soil and possibly groundwater quality. Beside the simulation of transport and degradation processes in the unsaturated zone and in the aquifer the analysis of the potential impact requires the estimation of quantity and temporal variation of wastewater exfiltration. Exfiltration can be assessed by the application of a leakage model. The hydrological approach was originally developed to simulate the interactions between the groundwater and surface water, it was adapted to allow for modelling of interactions between groundwater and sewer system. In order to approximate the exfiltration specific model parameters infiltration specific parameters were used as a basis. Scenario analysis of the exfiltration in the City of Dresden from 1997 to 1999 and during the flood event in August 2002 shows the variation and the extent of exfiltration rates.

  11. A software-based sensor for combined sewer overflows.

    Science.gov (United States)

    Leonhardt, G; Fach, S; Engelhard, C; Kinzel, H; Rauch, W

    2012-01-01

    A new methodology for online estimation of excess flow from combined sewer overflow (CSO) structures based on simulation models is presented. If sufficient flow and water level data from the sewer system is available, no rainfall data are needed to run the model. An inverse rainfall-runoff model was developed to simulate net rainfall based on flow and water level data. Excess flow at all CSO structures in a catchment can then be simulated with a rainfall-runoff model. The method is applied to a case study and results show that the inverse rainfall-runoff model can be used instead of missing rain gauges. Online operation is ensured by software providing an interface to the SCADA-system of the operator and controlling the model. A water quality model could be included to simulate also pollutant concentrations in the excess flow.

  12. Airflow in Gravity Sewers - Determination of Wastewater Drag Coefficient.

    Science.gov (United States)

    Bentzen, Thomas Ruby; Østertoft, Kristian Kilsgaard; Vollertsen, Jes; Fuglsang, Emil Dietz; Nielsen, Asbjørn Haaning

    2016-03-01

    Several experiments have been conducted in order to improve the understanding of the wastewater drag and the wall frictional force acting on the headspace air in gravity sewers. The aim of the study is to improve the data basis for a numerical model of natural sewer ventilation. The results of the study shows that by integrating the top/side wall shear stresses the log-law models for the air velocity distribution along the unwetted perimeter resulted in a good agreement with the friction forces calculated by use of the Colebrook-White formula for hydraulic smooth pipes. Secondly, the water surface drags were found by log-law models of the velocity distribution in turbulent flows to fit velocity profiles measured from the water surface and by integrating the water surface drags along the wetted perimeter, mean water surface drags were found and a measure of the water surface drag coefficient was found.

  13. The sewer collection system, the first treatment step

    International Nuclear Information System (INIS)

    Rustia, B.M.; Dickerson, J.R.

    2002-01-01

    'Full text:' The Civil Engineering Research Foundation's (CERF) Environmental Technology Evaluation Center (EvTEC) conducted an evaluation of a microbial treatment additive that converts the entire sewer collection system into an efficient high-speed treatment step. The technology claims to reduce total suspended solids (TSS) by > 60% and carbonaceous biological oxygen demand (CBOD), simultaneously by > 30% before it reaches the treatment plant. The technology uses pump station wet wells as the network nodes to add the microbial treatment to the waste water collection system This process uses the natural retention time in the sewer coupled with the addition of an extremely concentrated mixture of select, symbiotic, facultative microbes, which degrade the waste en route to the treatment plant. These bacteria do not produce odorous compounds and they replace the sulfur-reducing-bacteria (SRB) in the biomass on the walls of the force mains and on the wet perimeter of the gravity sewer piping by 'competitive exclusion.' This microbial substitution is achieved by the high quantity of organisms injected into the collection system. This reduces the sulfides in the wastewater thereby reducing the odor, along with greatly reducing the corrosion elements, which attack the piping in a sewer collection system. The objective of EvTEC evaluation was to verify the performance and reliability of such a microbial additive to treat wastewater and reduce plant 'sludges,' or biosolids. Among other performance issues, the evaluation addressed the technology's ability to treat domestic wastewater flows over an extended time period (i.e., greater than 3 months, 6 months, 12 months..., etc.) and to see if the benefits are improved during particular times of year. The benefits to using the additive include reducing the biosolids produced at the treatment plant and increasing the treatment plant's efficiency and capacity. This in turn helped reduce operating costs without requiring a large

  14. Radiation exposure of sewer workers associated with radioactive discharges from hospitals

    International Nuclear Information System (INIS)

    McDonnell, C.E.; Wilkins, S.

    1991-07-01

    Models have been developed to estimate the dispersion of radionuclides discharged into the sewer system serving a hospital where nuclear medicine and other techniques are used, and to assess the radiation doses to sewer workers and maintenance staff who may be exposed to these discharges. The dispersion model has been tested in a practical situation for the radionuclide 131 I. For a typical combination of hospital and sewer works, the estimated critical group doses arising from discharges of four selected radionuclides, 32 P, 99m Tc, 125 I and 131 I, are 30 μSv y -1 and 20 μSv y -1 respectively for a worker at the sewer works and for a sewer maintenance worker exposed for prolonged periods in the region of the sewer system adjacent to the hospital discharge point. (author)

  15. Peracetic Acid as a Green Disinfectant for Combined Sewer ...

    Science.gov (United States)

    This cooperative research and development agreement between U.S. EPA, Solvay, MSDGC, and CB&I is evaluating the potential of PAA for disinfection of Muddy Creek CSO wastewater and comparing that with sodium hypochlorite disinfection. This presentation will document the effectiveness of sodium hypochlorite and PAA for the inactivation of E. coli in CSO wastewater using laboratory bench-scale jar tests and Muddy Creek field site studies based on the following items:•Storage, shelf life, and application of the disinfectants.•Effectiveness of the disinfectants in the inactivation of E. coli.•Formation of harmful byproducts by the disinfectants.•Operation and maintenance costs, including the cost of the disinfectant, its storage, application, and neutralizing agent for the disinfectant to maintain the Ohio EPA guideline for residual disinfectant at the discharge point. Like many cities in the USA, Cincinnati, Ohio is attempting to find the best way to meet state and federal requirements concerning combined sewer overflow (CSO) wastewater. The Muddy Creek CSO treatment facility was constructed to provide treatment for CSO Numbers 198 and 216 from the Westwood Trunk sewer. The Metropolitan Sewer District of Greater Cincinnati (MSDGC) is currently using sodium hypochlorite for disinfection in this treatment facility. Because of degradation of hypochlorite during storage and the formation of chlorinated disinfection byproducts (DBPs), MSDGC is evaluating alternat

  16. CORAL off-line: an object-oriented tool for optimal control of sewer networks

    OpenAIRE

    Figueras, J.; Cembrano, Gabriela; Puig, Vicenç; Quevedo, Joseba; Salamero Sansalvado, María; Marti Marques, Joaquim

    2002-01-01

    This paper describes a tool to aid in the analysis and design of combined sewer networks. Complex drainage systems include actuators, like flow-diversion gates and detention tanks, which should be optimally controlled in order to minimize flooding and combined sewer overflow (CSO). Through these optimisations volume to waste water treatment plants (WWTP) is maximised. CORAL is a tool able to model a combined sewer network, simulate rain events, calculate actuators optimal policies, reproduce ...

  17. A novel method for rapid inspection of sewer networks: combining acoustic and optical means

    OpenAIRE

    Plihal, H.; Kretschmer, F.; Bin Ali, M.T.; See, C.H.; Romanova, A.; Horoshenkov, K.V.; Ertl, T.

    2015-01-01

    Operation and maintenance of the public sewer system represent key tasks for an\\ud operator. Condition assessment is usually conducted by conventional closed\\ud circuit television (CCTV) inspection. However, alternative tools such as\\ud manhole-zoom cameras (MZCs) and the acoustic technology SewerBatt® are\\ud available today.\\ud The INNOKANIS project investigates structural and operational condition\\ud assessment in the sewer system by means of 3 MZC models and SewerBatt® to\\ud develop a comb...

  18. Biological effects of geomagnetic storms

    International Nuclear Information System (INIS)

    Chibisov, S.M.; Breus, T.K.; Levitin, A.E.; Drogova, G.M.; AN SSSR, Moscow; AN SSSR, Moscow

    1995-01-01

    Six physiological parameters of cardio-vascular system of rabbits and ultrastructure of cardiomyocytes were investigated during two planetary geomagnetic storms. At the initial and main phase of the storm the normal circadian structure in each cardiovascular parameter was lost. The disynchronozis was growing together with the storm and abrupt drop of cardia activity was observed during the main phase of storm. The main phase of storm followed by the destruction and degradation of cardiomyocytes. Parameters of cardia activity became substantially synchronized and characterized by circadian rhythm structure while the amplitude of deviations was still significant at the recovery stage of geomagnetic storm. 3 refs.; 7 figs

  19. Great magnetic storms

    International Nuclear Information System (INIS)

    Tsurutani, B.T.; Yen Te Lee; Tang, F.; Gonzalez, W.D.

    1992-01-01

    The five largest magnetic storms that occurred between 1971 and 1986 are studied to determine their solar and interplanetary causes. All of the events are found to be associated with high speed solar wind streams led by collisionless shocks. The high speed streams are clearly related to identifiable solar flares. It is found that (1) it is the extreme values of the southward interplanetary magnetic fields rather than solar wind speeds that are the primary causes of great magnetic storms, (2) shocked and draped sheath fields preceding the driver gas (magnetic cloud) are at least as effective in causing the onset of great magnetic storms (3 of 5 events ) as the strong fields within the driver gas itself, and (3) precursor southward fields ahead of the high speed streams allow the shock compression mechanism (item 2) to be particularly geoeffective

  20. Towards robust optimal design of storm water systems

    Science.gov (United States)

    Marquez Calvo, Oscar; Solomatine, Dimitri

    2015-04-01

    In this study the focus is on the design of a storm water or a combined sewer system. Such a system should be capable to handle properly most of the storm to minimize the damages caused by flooding due to the lack of capacity of the system to cope with rain water at peak times. This problem is a multi-objective optimization problem: we have to take into account the minimization of the construction costs, the minimization of damage costs due to flooding, and possibly other criteria. One of the most important factors influencing the design of storm water systems is the expected amount of water to deal with. It is common that this infrastructure is developed with the capacity to cope with events that occur once in, say 10 or 20 years - so-called design rainfall events. However, rainfall is a random variable and such uncertainty typically is not taken explicitly into account in optimization. Rainfall design data is based on historical information of rainfalls, but many times this data is based on unreliable measures; or in not enough historical information; or as we know, the patterns of rainfall are changing regardless of historical information. There are also other sources of uncertainty influencing design, for example, leakages in the pipes and accumulation of sediments in pipes. In the context of storm water or combined sewer systems design or rehabilitation, robust optimization technique should be able to find the best design (or rehabilitation plan) within the available budget but taking into account uncertainty in those variables that were used to design the system. In this work we consider various approaches to robust optimization proposed by various authors (Gabrel, Murat, Thiele 2013; Beyer, Sendhoff 2007) and test a novel method ROPAR (Solomatine 2012) to analyze robustness. References Beyer, H.G., & Sendhoff, B. (2007). Robust optimization - A comprehensive survey. Comput. Methods Appl. Mech. Engrg., 3190-3218. Gabrel, V.; Murat, C., Thiele, A. (2014

  1. Storm and cloud dynamics

    CERN Document Server

    Cotton, William R

    1992-01-01

    This book focuses on the dynamics of clouds and of precipitating mesoscale meteorological systems. Clouds and precipitating mesoscale systems represent some of the most important and scientifically exciting weather systems in the world. These are the systems that produce torrential rains, severe winds including downburst and tornadoes, hail, thunder and lightning, and major snow storms. Forecasting such storms represents a major challenge since they are too small to be adequately resolved by conventional observing networks and numerical prediction models.Key Features* Key Highlight

  2. Multi-element sewer slime impact pattern--a quantitative characteristic enabling identification of the source of heavy metal discharges into sewer systems.

    Science.gov (United States)

    Kintrup, J; Wünsch, G

    2001-11-01

    The capability of sewer slime to accumulate heavy metals from municipal wastewater can be exploited to identify the sources of sewage sludge pollution. Former investigations of sewer slime looked for a few elements only and could, therefore, not account for deviations of the enrichment efficiency of the slime or for irregularities from sampling. Results of ICP-MS multi element determinations were analyzed by multivariate statistical methods. A new dimensionless characteristic "sewer slime impact" is proposed, which is zero for unloaded samples. Patterns expressed in this data format specifically extract the information required to identify the type of pollution and polluter quicker and with less effort and cost than hitherto.

  3. California's Perfect Storm

    Science.gov (United States)

    Bacon, David

    2010-01-01

    The United States today faces an economic crisis worse than any since the Great Depression of the 1930s. Nowhere is it sharper than in the nation's schools. Last year, California saw a perfect storm of protest in virtually every part of its education system. K-12 teachers built coalitions with parents and students to fight for their jobs and their…

  4. Dave Storm esitleb singlit

    Index Scriptorium Estoniae

    2002-01-01

    7. märtsil klubis Spirit ja 8. märtsil klubis Terminal presenteerib tallinlane DJ Dave Storm oma uut singlit "Ride", millel teeb laulmisega kaasa ameeriklane Charlie C. Singelplaadi annab peadselt välja Inglise plaadifirma Refunkt

  5. Interview with Gert Storm

    NARCIS (Netherlands)

    Storm, Gerrit

    2013-01-01

    Gert Storm studied biology at the Utrecht University, The Netherlands, and obtained his PhD degree in 1987 at the Department of Pharmaceutics of the same university. He is now Professor of targeted drug delivery at the University of Utrecht, as well as Professor of targeted therapeutics at the MIRA

  6. Association between Gastrointestinal Illness and Precipitation in Areas Impacted by Combined Sewer Systems: Utilizing a Distributed Lag Model

    Science.gov (United States)

    Combined sewer systems collect rainwater runoff, sewage, and industrial wastewater for transit to treatment facilities. With heavy precipitation, volumes can exceed capacity of treatment facilities, and wastewater discharges directly to receiving waters. These combined sewer over...

  7. Influence of Sewer Sediments on Flow Friction and Shear Stress Distribution

    DEFF Research Database (Denmark)

    Perrusquia, G.; Petersen, O.; Larsen, Torben

    1995-01-01

    Most sewers contain more or less deposited sediments. The paper discusses the distribution of the boundary shear stresses and the hydraulic resistance in part-full sewer pipes with such deposited sediments. The discussion is based on a series of numerical experiments using a validated numerical...

  8. Reconsidering Urban Sewer and Treatment Facilities in East Africa as Interplay of Flows, Networks and Spaces

    NARCIS (Netherlands)

    Letema, S.C.; Vliet, van B.J.M.; Lier, van J.B.

    2010-01-01

    Urbanization has brought about concentrations of people in densely populated settlements, resulting in the generation of waste water that needs to be disposed off in a hygienic way to avoid the outbreak of diseases. Decisions on what area to sewer, the nature of sewer schemes and treatment works to

  9. Cost Comparison of Conventional Gray Combined Sewer Overflow Control Infrastructure versus a Green/Gray Combination

    Science.gov (United States)

    This paper outlines a life-cycle cost analysis comparing a green (rain gardens) and gray (tunnels) infrastructure combination to a gray-only option to control combined sewer overflow in the Turkey Creek Combined Sewer Overflow Basin, in Kansas City, MO. The plan area of this Bas...

  10. The Characteristics of Waste Water Flow in a Danish Combined Sewer

    DEFF Research Database (Denmark)

    Schaarup-Jensen, Kjeld; Rasmussen, Michael R.

    2004-01-01

    have been analysed in order to extract some of their characteristics. Furthermore it is emphasised that the presence of a self-cleansing capacity of a combined sewer system is of vital importance in order to reduce the impact of combined sewer overflows on receiving waters. Whether or not the pipelines...

  11. Determination of an Optimal Trunk Sewer-line Route for Kikuyu ...

    African Journals Online (AJOL)

    The best alternative is a sewerage system that uses sewer-lines to convey sewage into a treatment works. This project seeks to replace the traditional methods currently used in Kikuyu Town with a sewerage system. Geospatial technologies are used to site a treatment plant and the main trunk sewer-line route in Kikuyu ...

  12. Leaching of additives from construction materials to urban storm water runoff.

    Science.gov (United States)

    Burkhardt, M; Zuleeg, S; Vonbank, R; Schmid, P; Hean, S; Lamani, X; Bester, K; Boller, M

    2011-01-01

    Urban water management requires further clarification about pollutants in storm water. Little is known about the release of organic additives used in construction materials and the impact of these compounds to storm water runoff. We investigated sources and pathways of additives used in construction materials, i.e., biocides in facades' render as well as root protection products in bitumen membranes for rooftops. Under wet-weather conditions, the concentrations of diuron, terbutryn, carbendazim, irgarol 1051 (all from facades) and mecoprop in storm water and receiving water exceeded the predicted no-effect concentrations values and the Swiss water quality standard of 0.1 microg/L. Under laboratory conditions maximum concentrations of additives were in the range of a few milligrams and a few hundred micrograms per litre in runoff of facades and bitumen membranes. Runoff from aged materials shows approximately one to two orders of magnitude lower concentrations. Concentrations decreased also during individual runoff events. In storm water and receiving water the occurrence of additives did not follow the typical first flush model. This can be explained by the release lasting over the time of rainfall and the complexity of the drainage network. Beside the amounts used, the impact of construction materials containing hazardous additives on water quality is related clearly to the age of the buildings and the separated sewer network. The development of improved products regarding release of hazardous additives is the most efficient way of reducing the pollutant load from construction materials in storm water runoff.

  13. Prioritizing sewer rehabilitation projects using AHP-PROMETHEE II ranking method.

    Science.gov (United States)

    Kessili, Abdelhak; Benmamar, Saadia

    2016-01-01

    The aim of this paper is to develop a methodology for the prioritization of sewer rehabilitation projects for Algiers (Algeria) sewer networks to support the National Sanitation Office in its challenge to make decisions on prioritization of sewer rehabilitation projects. The methodology applies multiple-criteria decision making. The study includes 47 projects (collectors) and 12 criteria to evaluate them. These criteria represent the different issues considered in the prioritization of the projects, which are structural, hydraulic, environmental, financial, social and technical. The analytic hierarchy process (AHP) is used to determine weights of the criteria and the Preference Ranking Organization Method for Enrichment Evaluations (PROMETHEE II) method is used to obtain the final ranking of the projects. The model was verified using the sewer data of Algiers. The results have shown that the method can be used for prioritizing sewer rehabilitation projects.

  14. Sewer solids separation by sedimentation--the problem of modeling, validation and transferability.

    Science.gov (United States)

    Kutzner, R; Brombach, H; Geiger, W F

    2007-01-01

    Sedimentation of sewer solids in tanks, ponds and similar devices is the most relevant process for the treatment of stormwater and combined sewer overflows in urban collecting systems. In the past a lot of research work was done to develop deterministic models for the description of this separation process. But these modern models are not commonly accepted in Germany until today. Water Authorities are sceptical with regard to model validation and transferability. Within this paper it is checked whether this scepticism is reasonable. A framework-proposal for the validation of mathematical models with zero or one dimensional spatial resolution for particle separation processes for stormwater and combined sewer overflow treatment is presented. This proposal was applied to publications of repute on sewer solids separation by sedimentation. The result was that none of the investigated models described in literature passed the validation entirely. There is an urgent need for future research in sewer solids sedimentation and remobilization!

  15. Local drainage analyses of the Paducah and Portsmouth Gaseous Diffusion Plants during an extreme storm

    International Nuclear Information System (INIS)

    Johnson, R.O.; Wang, J.C.; Lee, D.W.

    1993-01-01

    Local drainage analyses have been performed for the Paducah and Portsmouth Gaseous Diffusion Plants during an extreme storm having an approximate 10,000-yr recurrence interval. This review discusses the methods utilized to accomplish the analyses in accordance with US Department of Energy (DOE) design and evaluation guidelines, and summarizes trends, results, generalizations, and uncertainties applicable to other DOE facilities. Results indicate that some culverts may be undersized, and that the storm sewer system cannot drain the influx of precipitation from the base of buildings. Roofs have not been designed to sustain ponding when the primary drainage system is clogged. Some underground tunnels, building entrances, and ground level air intakes may require waterproofing

  16. Short-Term Forecasting of Urban Storm Water Runoff in Real-Time using Extrapolated Radar Rainfall Data

    DEFF Research Database (Denmark)

    Thorndahl, Søren Liedtke; Rasmussen, Michael R.

    2013-01-01

    Model based short-term forecasting of urban storm water runoff can be applied in realtime control of drainage systems in order to optimize system capacity during rain and minimize combined sewer overflows, improve wastewater treatment or activate alarms if local flooding is impending. A novel onl....... The radar rainfall extrapolation (nowcast) limits the lead time of the system to two hours. In this paper, the model set-up is tested on a small urban catchment for a period of 1.5 years. The 50 largest events are presented....... online system, which forecasts flows and water levels in real-time with inputs from extrapolated radar rainfall data, has been developed. The fully distributed urban drainage model includes auto-calibration using online in-sewer measurements which is seen to improve forecast skills significantly...

  17. Leonid storm research

    CERN Document Server

    Rietmeijer, Frans; Brosch, Noah; Fonda, Mark

    2000-01-01

    This book will appeal to all researchers that have an interest in the current Leonid showers It contains over forty research papers that present some of the first observational results of the November 1999 Leonid meteor storm, the first storm observed by modern observing techniques The book is a first glimpse of the large amount of information obtained during NASA's Leonid Multi-Instrument Aircraft Campaign and groundbased campaigns throughout the world It provides an excellent overview on the state of meteor shower research for any professional researcher or amateur meteor observer interested in studies of meteors and meteoroids and their relation to comets, the origin of life on Earth, the satellite impact hazard issue, and upper atmosphere studies of neutral atom chemistry, the formation of meteoric debris, persistent trains, airglow, noctilucent clouds, sprites and elves

  18. Combined sewer overflows impact on water quality and environmental ecosystem in the Harlem River

    Science.gov (United States)

    Wang, J.

    2017-12-01

    Combined sewer overflows (CSOs) discharge untreated sewage into the Harlem River during wet weather conditions, and it elevated nutrients and pathogen levels. It is not safe for swimming, fishing or boating especially in rainstorms. The Harlem River, a 9.3 mile long natural straight, connects the Hudson and East Rivers in New York City. It had been historically used for swimming, fishing, boating. Anthropogenic impacts have degraded water quality, limiting current aquatic activity in the river. CSOs water samples were collected during rainstorms, and analyzed in the laboratories of the Chemistry and Biology Department, Bronx Community College, City University of New York. Results showed elevated bacteria/pathogen and nutrient levels. Most recent data showed an ammonia concentration of 2.6 mg/L on July 30, 2015 during a heavy afternoon thunderstorm, and an ammonia level 2.7mg/L during tropical storm Arthur on July 2, 2014. Both significantly exceeded the EPA regulation level for NYC waters of 0.23mg/L. Phosphate levels peaked at 0.197 mg/L during a heavy thunderstorm on Apr 28, 2011, which was much higher than regulated level of 0.033 mg/L. Turbidity was 319 FAU during the July 30 2015 heavy thunderstorm, and was 882 FAU during tropical storm Arthur; which was significantly higher than regulation level of 5.25 FAU. CSOs collected during a recent heavy rainstorm on Oct 28, 2015, showed fecal coliform of 1 million MPN/100ml, E.Coli. of 60,000 MPN/100ml, and enterococcus of 65,000 MPN/100ml; which exceeded regulated levels of fecal coliform-200 MPN/100ml, E.Coli.-126 MPN/100ml, enterococcus-104 MPN/100ml. It is critical to reduce CSOs, restore ecosystem and improve water quality of the Harlem River. Green wall, green roof, and wetland had been used to reduce stormwater runoff & CSOs in the Bronx River; these green infrastructures are going to be used along the Harlem River waterfront as well. The goal of this research is to make the Harlem River swimmable and fishable

  19. A stable isotope approach for the quantification of sewer infiltration.

    Science.gov (United States)

    Kracht, Oliver; Gresch, Markus; Gujert, Willi

    2007-08-15

    Extraneous flows in wastewater collection systems are conventionally evaluated solely on the consideration of discharge hydrographs, which often involves a great degree of subjectivity and oversimplification. To obtain reliable information on the material fluxes within the urban environment, the use of intrinsic tracers can be the optimal choice. We demonstrate the successful use of naturally occurring stable isotopes of water (18O/16O and D/H) to accurately quantify extraneous discharge of groundwater in a combined sewer network. Fresh water supply from a distant hydrological regime provided usable isotopic separations between drinking water (proxy for real foul sewage) and local groundwater (proxy for sewer infiltration) of 1.8 per thousand in delta18O and 11.7 per thousand in 62H. Diurnal variation of wastewater isotopic composition reflected both the varying rates of foul sewage production and irregular dispersion effects in the pipe network. The latter suggest the existence of larger cumulative backwater zone volumes, which have not been attended to yet. Infiltrating groundwater contributed 39% (95% confidence interval = +/- 2.5%) of the total daily dry weather wastewater discharge. This paper discusses all relevant aspects for practical application of the method. It presents a comprehensive framework for uncertainty analysis and details on the detection and discrimination of possibly interfering effects.

  20. Detention storage volume for combined sewer overflow into a river.

    Science.gov (United States)

    Temprano, J; Tejero, I

    2002-06-01

    This article discusses the storage volume needed in a combined sewer system tank in order to preserve the water quality. There are a lot of design criteria which do not take into account the conditions of the receiving water, and as a result are inappropriate. A model was used to simulate the performance of a theoretical combined sewer system where a tank was located downstream. Results were obtained from the overflows produced by the rain recorded in Santander (Spain) for 11 years, with several combinations of storage volume and treatment capacity in the wastewater treatment plant. Quality criteria were also proposed for faecal coliforms, BOD, and total nitrogen to evaluate the effects from the overflows in the river water quality. Equations have been obtained which relate the number of overflows, the storage volume and the treatment plant capacity. The bacteriological pollution, quantified by means of faecal coliforms, was the analytical parameter which produced the most adverse effects in the river, so that more storage volume is needed (45 to 180 m3 ha(-1) net) than with other simulated pollutants (5 to 50 m3 ha(-1) net for BOD, and less than 4 m3 ha(-1) net for the total nitrogen). The increase in the treatment plant's capacity, from two to three times the flow in dry weather, reduces the impact on the river water in a more effective way, allowing a reduction of up to 65% in the number of overflows rather than increasing the storage volume.

  1. Management of sewer overflow structure in the FRG

    International Nuclear Information System (INIS)

    Leymann, G.

    1987-01-01

    Due to the geological morphology of the south and west of Germany, combined sewer systems are used to drain sewage and rain water in urban areas. In this system, industrial and domestic sewage as well as rain water flowing off areas with sealed surfaces are discharged into one pipe. Size and structure of this sewer system are designed to fulfil the criterium, that the total amount of water, stemming from rain events of an intensity not to be exceeded more than once a year, can be drained without flooding any part of the area considered. In the past, construction costs were reduced by building overflow structures at suitable sites; these structures discharge a volume of water exceeding five times the amount of water produced during dry weather in a most directly way in the outlet channel. In the sewage treatment plant, only two fifths of this remaining water volume was treated mechanically and biologically. Three fifths were discharged into the natural waters after mechanical treatment only

  2. [Early detection of occupational skin diseases in sewer workers].

    Science.gov (United States)

    Lang, V; Lauffer, F; Fincan, Y; Biedermann, T; Zink, A

    2018-04-25

    Skin diseases affect 30-70% of the world population, and globally, skin cancer rates are continuously increasing. In this respect, prevention programs and early detection of skin diseases are of particular importance. To screen sewer workers for skin diseases with regard to their work-related risk. Employees of the municipal utilities in Munich (Münchner Stadtentwässerung) underwent a whole-body examination of the skin, conducted by two dermatologists. In addition, all employees completed a paper-based questionnaire on risk behavior and preventive measures. We examined 81 employees (79 men, 2 women, mean age 45.7 ± 9.5 years). Skin lesions in need of treatment were found in 30.9% (n = 25): the most frequent diagnosis was mycosis pedis (16.1%). In addition, one employee was diagnosed with basal cell carcinoma and two with actinic keratoses. According to the questionnaire, 43.5% of the employees had undergone a physician-led skin cancer screening in the past, whereas sun-protection practices were rarely applied. According to our findings, employee skin cancer screening seems to be beneficial for the detection of work-related skin diseases and is associated with a high participation rate. Furthermore, the study suggests that sewer workers have a high rate of mycosis pedis, possibly a work-related effect.

  3. Dust storm, northern Mexico

    Science.gov (United States)

    1983-01-01

    This large dust storm along the left side of the photo, covers a large portion of the state of Coahuila, Mexico (27.5N, 102.0E). The look angle of this oblique photo is from the south to the north. In the foreground is the Sierra Madre Oriental in the states Coahuila and Nuevo Leon with the Rio Grande River, Amistad Reservoir and Texas in the background.

  4. Solar storms; Tormentas solares

    Energy Technology Data Exchange (ETDEWEB)

    Collaboration: Pereira Cuesta, S.; Pereira Pagan, B.

    2016-08-01

    Solar storms begin with an explosion, or solar flare, on the surface of the sun. The X-rays and extreme ultraviolet radiation from the flare reach the Earths orbit minutes later-travelling at light speed. The ionization of upper layers of our atmosphere could cause radio blackouts and satellite navigation errors (GPS). Soon after, a wave of energetic particles, electrons and protons accelerated by the explosion crosses the orbit of the Earth, and can cause real and significant damage. (Author)

  5. LibrarySTORM

    DEFF Research Database (Denmark)

    Breüner, Niels; Bech, Tine

    2013-01-01

    Når flere uddannelser samles i en nybygning til Campus C på Ceres grunden i Aarhus, skal der også indrettes et fælles bibliotek. Når der samtidig er midler til at arbejde med brugerdreven innovation, lå det lige for at inddrage de studerende og få deres visioner for fremtidens bibliotek. Der blev...... arrangeret en udviklingsdag, hvor der skulle brainstormes – og projektet blev kaldt LibrarySTORM....

  6. Modeling storm waves

    International Nuclear Information System (INIS)

    Benoit, M.; Marcos, F.; Teisson, Ch.

    1999-01-01

    Nuclear power stations located on the coast take the water they use to cool their circuits from the sea. The water intake and discharge devices must be able to operate in all weathers, notably during extreme storms, with waves 10 m high and over. To predict the impact of the waves on the equipment, they are modeled digitally from the moment they form in the middle of the ocean right up to the moment they break on the shore. (authors)

  7. Noise storm coordinated observations

    International Nuclear Information System (INIS)

    Elgaroey, Oe.; Tlamicha, A.

    1983-01-01

    The usually accepted bipolar model of noise storm centers is irrelevant for the present observations. An alternative model has been proposed in which the different sources of a noise storm center are located in different flux tubes connecting active regions with their surroundings. Radio emission is observed from the wide, descending branch of the flux tubes, opposite to the flaring site. The relation between the sense of circular polarization of the radio emission and the magnetic polarity, has been more precisely defined. The radiation is in the ordinary mode with respect to the underlying large scale photospheric magnetic polarity. Thus the ''irregular'' polarity of noice storm center ''B'' is explained. As regards center ''C'', one should note that although the observed radio emission is polarized in the ordinary mode with respect to the leading spot of region HR 17653, center ''C'' is not situated in flux tubes originating from the leading part of this region according to the proposed model. Rather, the radio sources are located in the wide and descending part of flux tubes connecting a large, quiet area of south magnetic polarity with the following part of the region HR 17653 (of north magnetic polarity). Thus it is the polarity of the extended area which determines the polarization of the radio emission. The observed polarization should result rather from the emission process than from complicated conditions of propagation for the radio waves

  8. [Effect of antecedent dry weather period on urban storm runoff pollution load].

    Science.gov (United States)

    Li, Li-qing; Yin, Cheng-qing; Kong, Ling-li; He, Qing-ci

    2007-10-01

    Twelve storm events were surveyed at Shilipu catchment in Wuhan City through three-year monitoring regime. The flow discharges, total suspended solids (TSS), chemical oxygen demand (COD), total nitrogen (TN), and total phosphorus (TP) in runoff were measured to study the mechanism of urban stormwater runoff pollution. The relationship between the event pollution load and the antecedent dry weather period was identified to discuss the influence of the urban surface sanitation management, operation of sewer pipe maintenance and rainfall characteristics on the urban stormwater runoff pollution. It was found that the antecedent dry weather period and runoff amount were the important determining factors in the generation of urban stormwater runoff pollution. The event pollution load was positively correlated to the antecedent dry weather period between two rainfall events (R2 = 0.95, p pollution loads. The best regression equation to estimate pollution load for storm events was developed based on the antecedent dry weather period and runoff depth. Source control including improving urban street sweeping activities and operation of sewer pipe maintenance should be made to reduce the amount of available pollutant over the dry days. It is important alternative to control urban stormwater runoff pollution for Hanyang District.

  9. Storm water runoff-a source of emerging contaminants in urban streams

    Science.gov (United States)

    Xia, K.; Chen, C.; FitzGerald, K.; Badgley, B.

    2016-12-01

    Emerging contaminants (ECs) that refers to prescription, over-the-counter, veterinary, and illicit drugs in addition to products intended to have primary effects on the human body, such as sunscreens and insect repellants. Historically municipal wastewater treatment effluent has been considered to be the main source of ECs in aquatic environment. However, recent investigations have suggested urban storm water runoff as an important source of ECs in the environment. The objective of this multi-year study was to investigate the occurrence of a wide range of ECs and the special and temporal change of 4-Nonlyphenol (4-NP), an endocrine disruptor, in a stream solely impacted by the storm water runoff from Blacksburg, VA. Urban land cover has doubled during the past 15 years surrounding this. Water and sediment samples were collected periodically along the stream during a 3-year period and analyzed for 4-NP using a gas chromatography/tandem mass spectrometry and for EC screening using an ultra- performance liquid chromatography/tandem mass spectrometry. In addition, human-associated Bacteroides sp. (HF183) was analyzed to explore possible cross contamination between the sewer system and storm water collection system of the city. Fifteen ECs were detected in water samples from various locations along the stream at estimated levels ranging from low ppt to low ppb. The levels of 4-NP in the storm water sediment samples, ranging from 30-1500 µg/kg (d.w.), positively correlated with the levels of Human-associated Bacteroides sp. (HF183) in the storm water. Our study suggested: 1) collective urban activity and leaky urban sewer systems are significant sources of ECs in storm water runoff that are often untreated or with minimum treatment before flowing into urban streams; and 2) sediment transport and re-suspension can further releases accumulated ECs back into stream water during rain events, resulting in occurrence of ECs downstream and possibly in the receiving river. This

  10. Factors that influence properties of FOG deposits and their formation in sewer collection systems.

    Science.gov (United States)

    Iasmin, Mahbuba; Dean, Lisa O; Lappi, Simon E; Ducoste, Joel J

    2014-02-01

    Understanding the formation of Fat, Oil, and Grease (FOG) deposits in sewer systems is critical to the sustainability of sewer collection systems since they have been implicated in causing sewerage blockages that leads to sanitary sewer overflows (SSOs). Recently, FOG deposits in sewer systems displayed strong similarities with calcium-based fatty acid salts as a result of a saponification reaction. The objective of this study was to quantify the factors that may affect the formation of FOG deposits and their chemical and rheological properties. These factors included the types of fats used in FSEs, environmental conditions (i.e. pH and temperature), and the source of calcium in sewer systems. The results of this study showed that calcium content in the calcium based salts seemed to depend on the solubility limit of the calcium source and influenced by pH and temperature conditions. The fatty acid profile of the calcium-based fatty acid salts produced under alkali driven hydrolysis were identical to the profile of the fat source and did not match the profile of field FOG deposits, which displayed a high fraction of palmitic, a long chain saturated fatty acid. It is hypothesized that selective microbial metabolism of fats and/or biologically induced hydrogenation may contribute to the FOG deposit makeup in sewer system. Therefore, selective removal of palmitic in pretreatment processes may be necessary prior to the discharge of FSE wastes into the sewer collection system. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. The use of multiple tracers to evaluate the impact of sewered and non-sewered development on coastal water quality in a rural area of Florida.

    Science.gov (United States)

    Meeroff, Daniel E; Bloetscher, Frederick; Long, Sharon C; Bocca, Thais

    2014-05-01

    When onsite wastewater treatment and disposal systems (OSTDS) are not sited appropriately or installed properly, wastewater constituents can be a source of adverse environmental impacts to soil and groundwater, which can lead to potential public health risks. A paired monitoring design developed to compare water quality in sewered and non-sewered areas is presented here. It is suggested as a possible monitoring scheme for assessing the impact of sewer installation projects. As such, two sets of single-family, rural residential Florida neighborhoods were evaluated over a two-year period to gain insight into the effects of small-community use of OSTDS on coastal water quality. One set of two neighborhoods were connected to the sanitary sewer network and the other set of two were served exclusively by OSTDS. Water quality sampling was conducted at the paired sites during seasonal high water table (SHWT) and seasonal low water table (SLWT) events. Measured surface water quality during the SHWT showed indications of environmental impacts from OSTDS in terms of nutrients, microbial pathogen indicators, and other water quality measures, such as turbidity and conductivity. However, during the SLWT events, no obvious impacts attributable to OSTDS were detected. The water quality results indicate that OSTDS impacts may be measureable in rural areas. Other factors, such as microbial indicator survival and regrowth potential, may confound the understanding of water quality impacts of sewer projects. For example, the microbial indicators Escherichia coli and enterococci were found to persist over time and therefore did not always represent true comparisons of OSTDS and sewered areas between seasons. The timeframe for evaluating the effects of sewer projects may be longer than anticipated because of this survival and regrowth phenomenon.

  12. The Ecology of Acidophilic Microorganisms in the Corroding Concrete Sewer Environment

    Directory of Open Access Journals (Sweden)

    Guangming Jiang

    2017-04-01

    Full Text Available Concrete corrosion is one of the most significant problems affecting valuable sewer infrastructure on a global scale. This problem occurs in the aerobic zone of the sewer, where a layer of surface corrosion develops on the exposed concrete and the surface pH is typically lowered from around 11–10 (pristine concrete to pH 2–4. Acidophilic microorganisms become established as biofilms within the concrete corrosion layer and enhance the loss of concrete mass. Until recently, the acidophilic community was considered to comprise relatively few species of microorganisms, however, the biodiversity of the corrosion community is now recognized as being extensive and varying from different sewer environmental conditions. The diversity of acidophiles in the corrosion communities includes chemolithoautotrophs, chemolithoheterotrophs, and chemoorganoheterotrophs. The activity of these microorganisms is strongly affected by H2S levels in the sewer gas phase, although CO2, organic matter, and iron in the corrosion layer influence this acidic ecosystem. This paper briefly presents the conditions within the sewer that lead to the development of concrete corrosion in that environment. The review focuses on the acidophilic microorganisms detected in sewer corrosion environments, and then summarizes their proposed functions and physiology, especially in relation to the corrosion process. To our knowledge, this is the first review of acidophilic corrosion microbial communities, in which, the ecology and the environmental conditions (when available are considered. Ecological studies of sewer corrosion are limited, however, where possible, we summarize the important metabolic functions of the different acidophilic species detected in sewer concrete corrosion layers. It is evident that microbial functions in the acidic sewer corrosion environment can be linked to those occurring in the analogous acidic environments of acid mine drainage and bioleaching.

  13. Radar Based Flow and Water Level Forecasting in Sewer Systems:a danisk case study

    OpenAIRE

    Thorndahl, Søren; Rasmussen, Michael R.; Grum, M.; Neve, S. L.

    2009-01-01

    This paper describes the first radar based forecast of flow and/or water level in sewer systems in Denmark. The rainfall is successfully forecasted with a lead time of 1-2 hours, and flow/levels are forecasted an additional ½-1½ hours using models describing the behaviour of the sewer system. Both radar data and flow/water level model are continuously updated using online rain gauges and online in-sewer measurements, in order to make the best possible predictions. The project show very promis...

  14. Principles and Approaches for Numerical Modelling of Sediment Transport in Sewers

    DEFF Research Database (Denmark)

    Mark, Ole; Appelgren, Cecilia; Larsen, Torben

    1995-01-01

    A study has been carried out with the objectives of describing the effect of sediment deposits on the hydraulic capacity of sewer systems and to investigate the sediment transport in sewer systems. A result of the study is a mathematical model MOUSE ST which describes sediment transport in sewers....... This paper discusses the applicability and the limitations of various modelling approaches and sediment transport formulations in in MOUSE ST. Further, the paper presents a simple application of MOUSE ST to the Rya catchment in Gothenburg, Sweden....

  15. Principles and approaches for numerical modelling of sediment transport in sewers

    DEFF Research Database (Denmark)

    Mark, Ole; Larsen, Torben; Appelgren, Cecilia

    1994-01-01

    model MOUSE ST which describes the sediment transport in sewers. This paper discusses the applicability and the limitations of various modelling approaches and sediment transport formulations in MOUSE ST. The study was founded by the Swedish Water and Waste Works Association and the Nordic Industrial......A study has been carried out at the University of Aalborg, Denmark and VBB VIAK, Sweden with the objectives to describe the effect of sediment deposits on the hydraulic capacity of sewer systems and to investigate the sediment transport in sewer systems. A results of the study is a mathematical...

  16. Empirical STORM-E Model. [I. Theoretical and Observational Basis

    Science.gov (United States)

    Mertens, Christopher J.; Xu, Xiaojing; Bilitza, Dieter; Mlynczak, Martin G.; Russell, James M., III

    2013-01-01

    Auroral nighttime infrared emission observed by the Sounding of the Atmosphere using Broadband Emission Radiometry (SABER) instrument onboard the Thermosphere-Ionosphere-Mesosphere Energetics and Dynamics (TIMED) satellite is used to develop an empirical model of geomagnetic storm enhancements to E-region peak electron densities. The empirical model is called STORM-E and will be incorporated into the 2012 release of the International Reference Ionosphere (IRI). The proxy for characterizing the E-region response to geomagnetic forcing is NO+(v) volume emission rates (VER) derived from the TIMED/SABER 4.3 lm channel limb radiance measurements. The storm-time response of the NO+(v) 4.3 lm VER is sensitive to auroral particle precipitation. A statistical database of storm-time to climatological quiet-time ratios of SABER-observed NO+(v) 4.3 lm VER are fit to widely available geomagnetic indices using the theoretical framework of linear impulse-response theory. The STORM-E model provides a dynamic storm-time correction factor to adjust a known quiescent E-region electron density peak concentration for geomagnetic enhancements due to auroral particle precipitation. Part II of this series describes the explicit development of the empirical storm-time correction factor for E-region peak electron densities, and shows comparisons of E-region electron densities between STORM-E predictions and incoherent scatter radar measurements. In this paper, Part I of the series, the efficacy of using SABER-derived NO+(v) VER as a proxy for the E-region response to solar-geomagnetic disturbances is presented. Furthermore, a detailed description of the algorithms and methodologies used to derive NO+(v) VER from SABER 4.3 lm limb emission measurements is given. Finally, an assessment of key uncertainties in retrieving NO+(v) VER is presented

  17. Storm Warnings for Cuba

    Science.gov (United States)

    1994-01-01

    Services: Telephone: (310) 451-7002; Fax: (310) 451-6915; Internet : order@rand.org. al Accesion For "Ni %&’ Storm WarningsDTI’ TAB E03 --- - - -for...reaction leading to an uncontrol- lable burgeoning of private entrepreneurial activity. As one observer 14See Acuerdo del Buro Politico , "Para llevar a...34 10Comisi6n de Relaciones Internacionales, Asamblea Nacional del Poder Popular, Datos, Reflexiones y Argumentos Sobre la Actual Situaci6n de Cuba, n.p

  18. The women day storm

    OpenAIRE

    Parnowski, Aleksei; Polonska, Anna; Semeniv, Oleg

    2012-01-01

    On behalf of the International Women Day, the Sun gave a hot kiss to our mother Earth in a form of a full halo CME generated by the yesterday's double X-class flare. The resulting geomagnetic storm gives a good opportunity to compare the performance of space weather forecast models operating in near-real-time. We compare the forecasts of most major models and identify some common problems. We also present the results of our own near-real-time forecast models.

  19. Influence of storm characteristics on soil erosion and storm runoff

    Science.gov (United States)

    Johnny M. III Grace

    2008-01-01

    Unpaved forest roads can be major sources of sediment from forested watersheds. Storm runoff from forest roads are a concern due to their potential delivery of sediments and nutrients to stream systems resulting in degraded water quality. The volume and sediment concentrations of stormwater runoff emanating from forest roads can be greatly influenced by storm...

  20. Deep Tunnel for Regulating Combined Sewer Overflow Pollution and Flood Disaster: A Case Study in Guangzhou City, China

    Directory of Open Access Journals (Sweden)

    Haichun Wu

    2016-08-01

    Full Text Available The DongHaoChong (DHC basin is located in the central city zone of Guangzhou City, China. Owing to the high density of buildings and low quality of the drainage pipe network in the city, diversion of rain and sewage is difficult. Waterlogging occurs frequently and combined sewer overflow (CSO pollution is a serious problem during the rainy season. Therefore, a deep tunnel for the DongHaoChong basin has been planned and its construction is currently underway. An urban rainstorm model for the DongHaoChong basin was developed on the basis of the Storm Water Management Model (SWMM, and both the interception effect of CSO pollution and the degree of mitigation of flood were analyzed. Reasonable scenarios for the deep tunnel in terms of rainstorms with different design recurrence periods were evaluated. From the viewpoints of preventing rainstorm waterlogging disasters and protecting water quality in the region downstream of DongHaoChong River, the river flood control and drainage capacities of the region were improved to a 2-year rainstorm design recurrence period by the construction of the deep tunnel. Furthermore, the main pollutant load of the CSO is expected to be reduced by about 30%–40%.

  1. Assessment of the service performance of drainage system and transformation of pipeline network based on urban combined sewer system model.

    Science.gov (United States)

    Peng, Hai-Qin; Liu, Yan; Wang, Hong-Wu; Ma, Lu-Ming

    2015-10-01

    In recent years, due to global climate change and rapid urbanization, extreme weather events occur to the city at an increasing frequency. Waterlogging is common because of heavy rains. In this case, the urban drainage system can no longer meet the original design requirements, resulting in traffic jams and even paralysis and post a threat to urban safety. Therefore, it provides a necessary foundation for urban drainage planning and design to accurately assess the capacity of the drainage system and correctly simulate the transport effect of drainage network and the carrying capacity of drainage facilities. This study adopts InfoWorks Integrated Catchment Management (ICM) to present the two combined sewer drainage systems in Yangpu District, Shanghai (China). The model can assist the design of the drainage system. Model calibration is performed based on the historical rainfall events. The calibrated model is used for the assessment of the outlet drainage and pipe loads for the storm scenario currently existing or possibly occurring in the future. The study found that the simulation and analysis results of the drainage system model were reliable. They could fully reflect the service performance of the drainage system in the study area and provide decision-making support for regional flood control and transformation of pipeline network.

  2. RTC simulations on large branched sewer systems with SmaRTControl.

    Science.gov (United States)

    de Korte, Kees; van Beest, Dick; van der Plaat, Marcel; de Graaf, Erno; Schaart, Niels

    2009-01-01

    In The Netherlands many large branched sewer systems exist. RTC can improve the performance of these systems. The objective of the universal algorithm of SmaRTControl is to improve the performance of the sewer system and the WWTP. The effect of RTC under rain weather flow conditions is simulated using a hydrological model with 19 drainage districts. The system related inefficiency coefficient (SIC) is introduced for assessment of the performance of sewer systems. The performance can be improved by RTC in combination with increased pumping capacities in the drainage districts, but without increasing the flow to the WWTP. Under dry weather flow conditions the flow to the WWTP can be equalized by storage of wastewater in the sewer system. It is concluded that SmaRTControl can improve the performance, that simulations are necessary and that SIC is an excellent parameter for assessment of the performance.

  3. Modelling of sedimentation and remobilization in in-line storage sewers for stormwater treatment.

    Science.gov (United States)

    Frehmann, T; Flores, C; Luekewille, F; Mietzel, T; Spengler, B; Geiger, W F

    2005-01-01

    A special arrangement of combined sewer overflow tanks is the in-line storage sewer with downstream discharge (ISS-down). This layout has the advantage that, besides the sewer system, no other structures are required for stormwater treatment. The verification of the efficiency with respect to the processes of sedimentation and remobilization of sediment within the in-line storage sewer with downstream discharge is carried out in a combination of a field and a pilot plant study. The model study was carried out using a pilot plant model scaled 1:13. The following is intended to present some results of the pilot plant study and the mathematical empirical modelling of the sedimentation and remobilization process.

  4. Demonstration of an Innovative Large-Diameter Sewer Rehabilitation Technology in Houston, Texas

    Science.gov (United States)

    While sewer renewal technologies currently being used for the repair, replacement and/or rehabilitation of deteriorating wastewater collection systems are generally effective, there is still room for improvement of existing technologies and for the development of new technologies...

  5. Demonstration of an Innovative Large-Diameter Sewer Rehabilitation Technology in Houston, Texas - slides

    Science.gov (United States)

    While sewer renewal technologies currently being used for the repair, replacement and/or rehabilitation of deteriorating wastewater collection systems are generally effective, there is still room for improvement of existing technologies and for the development of new technologies...

  6. Interactions between heavy metals and sewer slimes. Wechselwirkungen zwischen Schwermetallen und Sielhaut

    Energy Technology Data Exchange (ETDEWEB)

    Gutekunst, B.

    1989-09-01

    Sewer slimes in wastewater pipes are an efficient means for detecting heavy metals discharged into the sewer system. The chances and limits of this method are discussed on the basis of the interactions between the heavy metals and the sewer slime. Chemical processes which lead to an accumulation of heavy metals are precipitation, adsorption and sedimentation. The mobilization is due to dissolution, desorption and complexation. The dependency of the waste water parameters pH, redox potential, heavy metal concentration and speciation on the accumulation and mobilization of the heavy metals is investigated as well as the binding capacity and strength. The heavy metals speciations in sewer slime are estimated by the application of a sequential leaching technique. Finally the practical significance of the experiments is shown. (orig.).

  7. Design Of A Laboratory Set-up For Evaluating Structural Strength Of Deteriorated Concrete Sewer Pipes

    NARCIS (Netherlands)

    Stanic, N.; Salet, T.; Langeveld, J.G.; Clemens, F.H.L.R.

    2014-01-01

    The principle of structural behaviour of buried concrete pipes is fairly understood, except for how material deterioration affects structural behaviour and performance. Consequently, information on the structural behaviour of deteriorated sewer pipes will contribute to better understanding of the

  8. Anticoagulant resistance: a relevant issue in sewer rat (Rattus norvegicus) control?

    DEFF Research Database (Denmark)

    Heiberg, Ann-Charlotte

    2009-01-01

    the resistant rats, had resistance-related mutations in the VKORC1 gene. CONCLUSION: The results of this study suggest that the genetic background of anticoagulant resistance may have to be redefined in respect of resistance-related changes in the VKORC1 gene. Copyright © 2009 Society of Chemical Industry......BACKGROUND: The majority of rat problems in cities are thought to be related to defective sewers, and the use of anticoagulant rodenticides in such places is often implemented as part of regular urban rodent control. Knowledge pertaining to the resistance status of sewer rat populations is non......-existent, which may be leading to control problems in cities. It has become crucial to provide knowledge on the prevalence of resistance and how different control strategies have affected its prevalence among sewer rat populations. The prevalence of resistance was investigated in six sewer locations in Copenhagen...

  9. Determination of an Optimal Trunk Sewer-line Route for Kikuyu ...

    African Journals Online (AJOL)

    The proposed route utilises the existing road reserves, which help in minimising the costs ... and industries and conveys it using sewer pipes to a treatment works where it is treated and ..... Automating Utility Route Design and Planning through.

  10. Substorms during different storm phases

    Directory of Open Access Journals (Sweden)

    N. Partamies

    2011-11-01

    Full Text Available After the deep solar minimum at the end of the solar cycle 23, a small magnetic storm occurred on 20–26 January 2010. The Dst (disturbance storm time index reached the minimum of −38 nT on 20 January and the prolonged recovery that followed the main phase that lasted for about 6 days. In this study, we concentrate on three substorms that took place (1 just prior to the storm, (2 during the main phase of the storm, and (3 at the end of the recovery of the storm. We analyse the solar wind conditions from the solar wind monitoring spacecraft, the duration and intensity of the substorm events as well as the behaviour of the electrojet currents from the ground magnetometer measurements. We compare the precipitation characteristics of the three substorms. The results show that the F-region electron density enhancements and dominant green and red auroral emission of the substorm activity during the storm recovery resembles average isolated substorm precipitation. However, the energy dissipated, even at the very end of a prolonged storm recovery, is very large compared to the typical energy content of isolated substorms. In the case studied here, the dissipation of the excess energy is observed over a 3-h long period of several consecutive substorm intensifications. Our findings suggest that the substorm energy dissipation varies between the storm phases.

  11. Multi-element sewer slime impact pattern - a quantitative characteristic enabling identification of the source of heavy metal discharges into sewer systems

    Energy Technology Data Exchange (ETDEWEB)

    Kintrup, J. [Chemistry Lab., Wessling GmbH, Hannover (Germany); Wuensch, G. [Lehrgebiet Analytische Chemie, Univ. Hannover (Germany)

    2001-11-01

    The capability of sewer slime to accumulate heavy metals from municipal wastewater can be exploited to identify the sources of sewage sludge pollution. Former investigations of sewer slime looked for a few elements only and could, therefore, not account for deviations of the enrichment efficiency of the slime or for irregularities from sampling. Results of ICP-MS multi element determinations were analyzed by multivariate statistical methods. A new dimensionless characteristic ''sewer slime impact'' is proposed, which is zero for unloaded samples. Patterns expressed in this data format specifically extract the information required to identify the type of pollution and polluter quicker and with less effort and cost than hitherto. (orig.)

  12. Environmental assessment of sewer construction in small to medium sized cities using life cycle assessment

    OpenAIRE

    Petit, Anna

    2014-01-01

    In a world with an increasing urban population, analysing the construction impacts of sanitation infrastructures through Life Cycle Assessment (LCA) is necessary for defining the best environmental management strategies. In this study, the environmental impacts of one linear meter of sewer constructive solution were analysed for different pipe materials and diameters used in Southern Europe; a unit of different sewer appurtenances (pump, manhole and inspection chamber) was also considered. Th...

  13. Receding horizon control of hybrid linear delayed systems: Application to sewer networks

    OpenAIRE

    Joseph-Duran, Bernat; Ocampo-Martinez, Carlos; Cembrano, Gabriela

    2013-01-01

    A control-oriented hybrid linear model for water transport in sewer networks is proposed as a suitable framework for the computation of real-time controllers for the minimization of flooding in presence of heavy-rain events. The model is based on individual network elements (sewers, gates, weirs and tanks) and does not rely on topological simplifications, thus providing a better description of the hydrological and hydraulic phenomena than in similar works. Using a generic form of a hybrid lin...

  14. Relationship between substorms and storms

    International Nuclear Information System (INIS)

    Kamide, Y.

    1980-01-01

    In an attempt to deduce a plausible working model of the relationship between magnetospheric substorms and storms, recent relevant studies of various processes occurring during disturbed periods are integrated along with some theoretical suggestions. It has been shown that the main phase of geomagnetic storms is associated with the successive occurrence of intense substorms and with the sustained southward component of the interplanetary magnetic field (IMF). However, these relations are only qualitatively understood, and thus basic questions remain unanswered involving the hypothesis whether a magnetic storm is a non-linear (or linear) superposition of intense substorms, each of which constitutes an elementary storm, or the main phase of magnetic storms occurs as a result of the intense southward IMF which enhances magnetospheric convection and increases occurrence probability of substorms. (Auth.)

  15. Thyroid storm: an updated review.

    Science.gov (United States)

    Chiha, Maguy; Samarasinghe, Shanika; Kabaker, Adam S

    2015-03-01

    Thyroid storm, an endocrine emergency first described in 1926, remains a diagnostic and therapeutic challenge. No laboratory abnormalities are specific to thyroid storm, and the available scoring system is based on the clinical criteria. The exact mechanisms underlying the development of thyroid storm from uncomplicated hyperthyroidism are not well understood. A heightened response to thyroid hormone is often incriminated along with increased or abrupt availability of free hormones. Patients exhibit exaggerated signs and symptoms of hyperthyroidism and varying degrees of organ decompensation. Treatment should be initiated promptly targeting all steps of thyroid hormone formation, release, and action. Patients who fail medical therapy should be treated with therapeutic plasma exchange or thyroidectomy. The mortality of thyroid storm is currently reported at 10%. Patients who have survived thyroid storm should receive definite therapy for their underlying hyperthyroidism to avoid any recurrence of this potentially fatal condition. © The Author(s) 2013.

  16. Conceptual design report, 200 Area sanitary sewer system: Project 96L-EWL-116

    International Nuclear Information System (INIS)

    Pursley, D.L.

    1994-01-01

    Project L-116 will install an integrated sanitary sewer system in the 200 Area. This new system will connect existing sewer systems for facilities that have a foreseeable future, provide capacity and routing for future facilities, and install new septic sewer systems for existing facilities that cannot be feasibly connected to the new sewer system and have a mission that will extend beyond the year 2000. Project L-116 will construct a sanitary sewer collection, treatment, and disposal system for facilities in the 200-East and -West Areas and adjacent areas located on the 200 Area plateau. The existing septic systems will be abandoned or decommissioned in accordance with applicable Washington State and local codes and regulations. The conceptual design for the sanitary sewer system is designed around population forecasts of 5,000 people for 200-West Area and 9,000 people for 200-East Area. The definitive design will be based on the latest forecast populations at the time definitive design is initiated

  17. Assessment of erosion and sedimentation dynamic in a combined sewer network using online turbidity monitoring.

    Science.gov (United States)

    Bersinger, T; Le Hécho, I; Bareille, G; Pigot, T

    2015-01-01

    Eroded sewer sediments are a significant source of organic matter discharge by combined sewer overflows. Many authors have studied the erosion and sedimentation processes at the scale of a section of sewer pipe and over short time periods. The objective of this study was to assess these processes at the scale of an entire sewer network and over 1 month, to understand whether phenomena observed on a small scale of space and time are still valid on a larger scale. To achieve this objective the continuous monitoring of turbidity was used. First, the study of successive rain events allows observation of the reduction of the available sediment and highlights the widely different erosion resistance for the different sediment layers. Secondly, calculation of daily chemical oxygen demand (COD) fluxes during the entire month was performed showing that sediment storage in the sewer pipe after a rain period is important and stops after 5 days. Nevertheless, during rainfall events, the eroded fluxes are more important than the whole sewer sediment accumulated during a dry weather period. This means that the COD fluxes promoted by runoff are substantial. This work confirms, with online monitoring, most of the conclusions from other studies on a smaller scale.

  18. Separate and combined sewer systems: a long-term modelling approach.

    Science.gov (United States)

    Mannina, Giorgio; Viviani, Gaspare

    2009-01-01

    Sewer systems convey mostly dry weather flow, coming from domestic and industrial sanitary sewage as well as infiltration flow, and stormwater due to meteoric precipitations. Traditionally, in urban drainage two types of sewer systems are adopted: separate and combined sewers. The former convey dry and wet weather flow separately into two different networks, while the latter convey dry and wet weather flow together. Which is the best solution in terms of cost-benefit analysis still remains a controversial subject. The present study was aimed at comparing the pollution loads discharged to receiving bodies by Wastewater Treatment Plant (WWTP) and Combined Sewer Overflow (CSO) for different kinds of sewer systems (combined and separate). To accomplish this objective, a comparison between the two systems was carried out using results from simulations of catchments characterised by different dimensions, population densities and water supply rate. The analysis was based on a parsimonious mathematical model able to simulate the sewer system as well as the WWTP during both dry and wet weather. The rain series employed for the simulations was six years long. Several pollutants, both dissolved and particulate, were modelled. The results confirmed the uncertainties in the choice of one system versus the other, emphasising the concept that case-by-case solutions have to be undertaken. Further, the compared systems showed different responses in terms of effectiveness in reducing the discharged mass to the RWB in relation to the particular pollutant taken into account.

  19. Geomagnetic storm forecasting service StormFocus: 5 years online

    Science.gov (United States)

    Podladchikova, Tatiana; Petrukovich, Anatoly; Yermolaev, Yuri

    2018-04-01

    Forecasting geomagnetic storms is highly important for many space weather applications. In this study, we review performance of the geomagnetic storm forecasting service StormFocus during 2011-2016. The service was implemented in 2011 at SpaceWeather.Ru and predicts the expected strength of geomagnetic storms as measured by Dst index several hours ahead. The forecast is based on L1 solar wind and IMF measurements and is updated every hour. The solar maximum of cycle 24 is weak, so most of the statistics are on rather moderate storms. We verify quality of selection criteria, as well as reliability of real-time input data in comparison with the final values, available in archives. In real-time operation 87% of storms were correctly predicted while the reanalysis running on final OMNI data predicts successfully 97% of storms. Thus the main reasons for prediction errors are discrepancies between real-time and final data (Dst, solar wind and IMF) due to processing errors, specifics of datasets.

  20. Thromboembolic complications of thyroid storm.

    Science.gov (United States)

    Min, T; Benjamin, S; Cozma, L

    2014-01-01

    Thyroid storm is a rare but potentially life-threatening complication of hyperthyroidism. Early recognition and prompt treatment are essential. Atrial fibrillation can occur in up to 40% of patients with thyroid storm. Studies have shown that hyperthyroidism increases the risk of thromboembolic events. There is no consensus with regard to the initiation of anticoagulation for atrial fibrillation in severe thyrotoxicosis. Anticoagulation is not routinely initiated if the risk is low on a CHADS2 score; however, this should be considered in patients with thyroid storm or severe thyrotoxicosis with impending storm irrespective of the CHADS2 risk, as it appears to increase the risk of thromboembolic episodes. Herein, we describe a case of thyroid storm complicated by massive pulmonary embolism. Diagnosis of thyroid storm is based on clinical findings. Early recognition and prompt treatment could lead to a favourable outcome.Hypercoagulable state is a recognised complication of thyrotoxicosis.Atrial fibrillation is strongly associated with hyperthyroidism and thyroid storm.Anticoagulation should be considered for patients with severe thyrotoxicosis and atrial fibrillation irrespective of the CHADS2 score.Patients with severe thyrotoxicosis and clinical evidence of thrombosis should be immediately anticoagulated until hyperthyroidism is under control.

  1. IRI STORM validation over Europe

    Science.gov (United States)

    Haralambous, Haris; Vryonides, Photos; Demetrescu, Crişan; Dobrică, Venera; Maris, Georgeta; Ionescu, Diana

    2014-05-01

    The International Reference Ionosphere (IRI) model includes an empirical Storm-Time Ionospheric Correction Model (STORM) extension to account for storm-time changes of the F layer peak electron density (NmF2) during increased geomagnetic activity. This model extension is driven by past history values of the geomagnetic index ap (The magnetic index applied is the integral of ap over the previous 33 hours with a weighting function deduced from physically based modeling) and it adjusts the quiet-time F layer peak electron density (NmF2) to account for storm-time changes in the ionosphere. In this investigation manually scaled hourly values of NmF2 measured during the main and recovery phases of selected storms for the maximum solar activity period of the current solar cycle are compared with the predicted IRI-2012 NmF2 over European ionospheric stations using the STORM model option. Based on the comparison a subsequent performance evaluation of the STORM option during this period is quantified.

  2. Application of the Wallingford Procedure to sewer network rehabilitation. Rehabilitacion de redes de alcantarillado. Aplicando el sistema de Wallingford

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, M. (Universidad Politecnica de de Cataluna. Barcelona (Spain)); Lopez, R. (Universitat de Lleida. Lleida (Spain))

    1999-01-01

    In this paper we present a summary of the Wallingford Procedure application to sewer network rehabilitation studies. After the methodology of the Procedure is revised, an application to a sewer network of Sant Boi de Llobregat is showed. Flow survey campaigns, calibration and validation processes and the alternative proposed to improve the initial situation are described. Finally, the benefits to apply such methodologies to the sewer network rehabilitation analysis are exposed. (Author) 3 refs.

  3. Application of the Wallingford Procedure to sewer network rehabilitation; Rehabilitacion de redes de alcantarillado. Aplicando el sistema de Wallingford

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, M. [Universidad Politecnica de de Cataluna. Barcelona (Spain); Lopez, R. [Universitat de Lleida. Lleida (Spain)

    1999-11-01

    In this paper we present a summary of the Wallingford Procedure application to sewer network rehabilitation studies. After the methodology of the Procedure is revised, an application to a sewer network of Sant Boi de Llobregat is showed. Flow survey campaigns, calibration and validation processes and the alternative proposed to improve the initial situation are described. Finally, the benefits to apply such methodologies to the sewer network rehabilitation analysis are exposed. (Author) 3 refs.

  4. Resistance to anticoagulants in rats (Rattus norvegicus) in sewers in an urban area

    DEFF Research Database (Denmark)

    Lodal, Jens

    2007-01-01

    primarily tested for possible resistance to coumatetralyl, bromadiolone and difenacoum by Blood Clotting Response tests. Feeding test was used in tests for resistance to difethialone. A total of 24 rats trapped in sewers at 15 locations were tested. Resistance to bromadiolone was found among rats from all......Control of rats in sewers is, though of varying intensity, common practice in a majority of Danish municipalities and bromadiolone is the most preferred active ingredient. The results of sewer rat control is very difficult to register and very little is known about resistance among sewer rats...

  5. Risk assessment of radionuclide discharges to sanitary sewers

    International Nuclear Information System (INIS)

    Galpin, F.L.; Merrell, G.; Rogers, V.C.

    1996-01-01

    This presentation describes the basic approach and conduct of a study of the possible risks and consequences of radionuclide discharges into a sewage treatment system. The study's objective was to determine if there were any possible significant exposures to either WSSC workers or the public form the discharge of radioactive material into the sewer system. The conduct of this study included a review of applicable regulations, and a case study of some past contamination events. The evaluation of potential occupational exposures involved measurements in the collection system were selected based on their location relative to potential dischargers. Measurement points at the treatment works were selected at points where biosolids might accumulate. Both passive, (TLD) and active, (scintillation detector) measurements were made. A limited number of samples were taken and analyzed. Potential doses to the public were estimated based on the possible pathways to man. Due both to limited resources and other project constraints several assumptions and bounding calculations were necessary to meet the objective. Although the study concluded that there were no present significant health concerns, followup evaluations were recommended. 7 refs., 1 fig., 1 tab

  6. Fractal analysis of urban environment: land use and sewer system

    Science.gov (United States)

    Gires, A.; Ochoa Rodriguez, S.; Van Assel, J.; Bruni, G.; Murla Tulys, D.; Wang, L.; Pina, R.; Richard, J.; Ichiba, A.; Willems, P.; Tchiguirinskaia, I.; ten Veldhuis, M. C.; Schertzer, D. J. M.

    2014-12-01

    Land use distribution are usually obtained by automatic processing of satellite and airborne pictures. The complexity of the obtained patterns which are furthermore scale dependent is enhanced in urban environment. This scale dependency is even more visible in a rasterized representation where only a unique class is affected to each pixel. A parameter commonly analysed in urban hydrology is the coefficient of imperviousness, which reflects the proportion of rainfall that will be immediately active in the catchment response. This coefficient is strongly scale dependent with a rasterized representation. This complex behaviour is well grasped with the help of the scale invariant notion of fractal dimension which enables to quantify the space occupied by a geometrical set (here the impervious areas) not only at a single scale but across all scales. This fractal dimension is also compared to the ones computed on the representation of the catchments with the help of operational semi-distributed models. Fractal dimensions of the corresponding sewer systems are also computed and compared with values found in the literature for natural river networks. This methodology is tested on 7 pilot sites of the European NWE Interreg IV RainGain project located in France, Belgium, Netherlands, United-Kingdom and Portugal. Results are compared between all the case study which exhibit different physical features (slope, level of urbanisation, population density...).

  7. US Weather Bureau Storm Reports

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Weather Bureau and US Army Corps and other reports of storms from 1886-1955. Hourly precipitation from recording rain gauges captured during heavy rain, snow,...

  8. Toward an integrated storm surge application: ESA Storm Surge project

    Science.gov (United States)

    Lee, Boram; Donlon, Craig; Arino, Olivier

    2010-05-01

    Storm surges and their associated coastal inundation are major coastal marine hazards, both in tropical and extra-tropical areas. As sea level rises due to climate change, the impact of storm surges and associated extreme flooding may increase in low-lying countries and harbour cities. Of the 33 world cities predicted to have at least 8 million people by 2015, at least 21 of them are coastal including 8 of the 10 largest. They are highly vulnerable to coastal hazards including storm surges. Coastal inundation forecasting and warning systems depend on the crosscutting cooperation of different scientific disciplines and user communities. An integrated approach to storm surge, wave, sea-level and flood forecasting offers an optimal strategy for building improved operational forecasts and warnings capability for coastal inundation. The Earth Observation (EO) information from satellites has demonstrated high potential to enhanced coastal hazard monitoring, analysis, and forecasting; the GOCE geoid data can help calculating accurate positions of tide gauge stations within the GLOSS network. ASAR images has demonstrated usefulness in analysing hydrological situation in coastal zones with timely manner, when hazardous events occur. Wind speed and direction, which is the key parameters for storm surge forecasting and hindcasting, can be derived by using scatterometer data. The current issue is, although great deal of useful EO information and application tools exist, that sufficient user information on EO data availability is missing and that easy access supported by user applications and documentation is highly required. Clear documentation on the user requirements in support of improved storm surge forecasting and risk assessment is also needed at the present. The paper primarily addresses the requirements for data, models/technologies, and operational skills, based on the results from the recent Scientific and Technical Symposium on Storm Surges (www

  9. Magnetic storms and induction hazards

    Science.gov (United States)

    Love, Jeffrey J.; Rigler, E. Joshua; Pulkkinen, Antti; Balch, Christopher

    2014-01-01

    Magnetic storms are potentially hazardous to the activities and technological infrastructure of modern civilization. This reality was dramatically demonstrated during the great magnetic storm of March 1989, when surface geoelectric fields, produced by the interaction of the time-varying geomagnetic field with the Earth's electrically conducting interior, coupled onto the overlying Hydro-Québec electric power grid in Canada. Protective relays were tripped, the grid collapsed, and about 9 million people were temporarily left without electricity [Bolduc, 2002].

  10. [Thyroid Storm and Myxedema Coma].

    Science.gov (United States)

    Milkau, Malte; Sayk, Friedhelm

    2018-03-01

    Thyroid storm and myxedema coma are the most severe clinical forms of thyroid dysfunction. While both hyper- and hypothyroidsm are common diseases, thyroid storm and myxedema coma are rare. Due to their unspecific signs and symptoms they are often difficult to diagnose. Both disorders are medical emergencies, which still show a significant mortality. The following article summarizes diagnostic tools and treatment options for these disorders. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Coastal Storm Surge Analysis: Storm Forcing. Report 3. Intermediate Submission No. 1.3

    Science.gov (United States)

    2013-07-01

    The storm surge study considers both tropical storms and extratropical cyclones for determination of return period storm surge elevations. The...Appendix B: Extratropical Cyclone Selection in Support of FEMA Region III Storm Surge Modeling...stations applied in the storm selection process. ............................................. 56  Table B2. Extratropical cyclones selected from the

  12. Effects of the May 5-6, 1973, storm in the Greater Denver area, Colorado

    Science.gov (United States)

    Hansen, Wallace R.

    1973-01-01

    Rain began falling on the Greater Denver area the evening of Saturday, May 5, 1973, and continued through most of Sunday, May 6. Below about 7,000 feet altitude, the precipitation was mostly rain; above that altitude, it was mostly snow. Although the rate of fall was moderate, at least 4 inches of rain or as much as 4 feet of snow accumulated in some places. Sustained precipitation falling at a moderate rate thoroughly saturated the ground and by midday Sunday sent most of the smaller streams into flood stage. The South Platte River and its major tributaries began to flood by late Sunday evening and early Monday morning. Geologic and hydrologic processes activated by the May 5-6 storm caused extensive damage to lands and to manmade structures in the Greater Denver area. Damage was generally most intense in areas where man had modified the landscape--by channel constrictions, paving, stripping of vegetation and topsoil, and oversteepening of hillslopes. Roads, bridges, culverts, dams, canals, and the like were damaged or destroyed by erosion and sedimentation. Streambanks and structures along them were scoured. Thousands of acres of croplands, pasture, and developed urban lands were coated with mud and sand. Flooding was intensified by inadequate storm sewers, blocked drains, and obstructed drainage courses. Saturation of hillslopes along the Front Range caused rockfalls, landslides, and mudflows as far west as Berthoud Pass. Greater attention to geologic conditions in land-use planning, design, and construction would minimize storm damage in the future.

  13. Influence of pipe material and surfaces on sulfide related odor and corrosion in sewers.

    Science.gov (United States)

    Nielsen, Asbjørn Haaning; Vollertsen, Jes; Jensen, Henriette Stokbro; Wium-Andersen, Tove; Hvitved-Jacobsen, Thorkild

    2008-09-01

    Hydrogen sulfide oxidation on sewer pipe surfaces was investigated in a pilot scale experimental setup. The experiments were aimed at replicating conditions in a gravity sewer located immediately downstream of a force main where sulfide related concrete corrosion and odor is often observed. During the experiments, hydrogen sulfide gas was injected intermittently into the headspace of partially filled concrete and plastic (PVC and HDPE) sewer pipes in concentrations of approximately 1,000 ppm(v). Between each injection, the hydrogen sulfide concentration was monitored while it decreased because of adsorption and subsequent oxidation on the pipe surfaces. The experiments showed that the rate of hydrogen sulfide oxidation was approximately two orders of magnitude faster on the concrete pipe surfaces than on the plastic pipe surfaces. Removal of the layer of reaction (corrosion) products from the concrete pipes was found to reduce the rate of hydrogen sulfide oxidation significantly. However, the rate of sulfide oxidation was restored to its background level within 10-20 days. A similar treatment had no observable effect on hydrogen sulfide removal in the plastic pipe reactors. The experimental results were used to model hydrogen sulfide oxidation under field conditions. This showed that the gas-phase hydrogen sulfide concentration in concrete sewers would typically amount to a few percent of the equilibrium concentration calculated from Henry's law. In the plastic pipe sewers, significantly higher concentrations were predicted because of the slower adsorption and oxidation kinetics on such surfaces.

  14. The distribution dynamics and desorption behaviour of mobile pharmaceuticals and caffeine to combined sewer sediments.

    Science.gov (United States)

    Hajj-Mohamad, M; Darwano, H; Duy, S Vo; Sauvé, S; Prévost, M; Arp, H P H; Dorner, S

    2017-01-01

    Pharmaceuticals are discharged to the environment from wastewater resource recovery facilities, sewer overflows, and illicit sewer connections. To understand the fate of pharmaceuticals, there is a need to better understand their sorption dynamics to suspended sediments (SS) and settled sediments (StS) in sewer systems. In this study, such sorption dynamics to both SS and StS were assessed using a batch equilibrium method under both static and dynamic conditions. Experiments were performed with natively occurring and artificially modified concentrations of sewer pharmaceuticals (acetaminophen, theophylline, carbamazepine, and a metabolite of carbamazepine) and caffeine. Differences in apparent distribution coefficients, K d,app , between SS and StS were related to differences in their organic carbon (OC) content, and the practice of artificially modifying the concentration. K d,app values of modified contaminant concentrations and high OC sediments were substantially higher. Pseudo-second order desorption rates for these mobile compounds were also quantified. Successive flushing events to simulate the addition of stormwater to sewer networks revealed that aqueous concentrations would not necessarily decrease, because the added water will rapidly return to equilibrium concentrations with the sediments. Sorption and desorption kinetics must be considered in addition to dilution, to avoid underestimating the influence of dilution on concentrations of pharmaceuticals discharged to the environment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Estimation of Parameters and Flow Characteristics for the Design of Sanitary Sewers in Malaysia

    Directory of Open Access Journals (Sweden)

    Kamran Ansari

    2013-01-01

    Full Text Available Determination of the flow characteristics is very important for the design of sanitary sewers in any area. In the present study these are determined in the running sewers for the two parameters; per capita flow contribution and the peak flow factor. ISCO area - velocity flow meter model 4250 is used for this purpose. The flow meter, before being used in the running sewers, is calibrated first in the Hydraulics and Hydrology Laboratory of the UTM (Universiti Teknologi Malaysia. During the study the flow meter is installed inside the manhole in 10 different phases in the months of June, August, September, and October 2005 to monitor the sewage flow running in it. Continuous data is recorded in the flow meter during the process and the recorded time varies between 47 hours 25 minutes and 128 hours 35 minutes. The rainfall data is also collected during the same time using an automatic rain gauge which recorded rainfall at every five minutes of interval. Both the parameters thus calculated are then compared with the Malaysian Standard for sewer design i.e. MS 1228:1991. The results show that higher values of these parameters are being used in the design of sanitary sewers and extensive study needs to be carried out to review these values for future use

  16. A risk-based approach to sanitary sewer pipe asset management.

    Science.gov (United States)

    Baah, Kelly; Dubey, Brajesh; Harvey, Richard; McBean, Edward

    2015-02-01

    Wastewater collection systems are an important component of proper management of wastewater to prevent environmental and human health implications from mismanagement of anthropogenic waste. Due to aging and inadequate asset management practices, the wastewater collection assets of many cities around the globe are in a state of rapid decline and in need of urgent attention. Risk management is a tool which can help prioritize resources to better manage and rehabilitate wastewater collection systems. In this study, a risk matrix and a weighted sum multi-criteria decision-matrix are used to assess the consequence and risk of sewer pipe failure for a mid-sized city, using ArcGIS. The methodology shows that six percent of the uninspected sewer pipe assets of the case study have a high consequence of failure while four percent of the assets have a high risk of failure and hence provide priorities for inspection. A map incorporating risk of sewer pipe failure and consequence is developed to facilitate future planning, rehabilitation and maintenance programs. The consequence of failure assessment also includes a novel failure impact factor which captures the effect of structurally defective stormwater pipes on the failure assessment. The methodology recommended in this study can serve as a basis for future planning and decision making and has the potential to be universally applied by municipal sewer pipe asset managers globally to effectively manage the sanitary sewer pipe infrastructure within their jurisdiction. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Evidence for fat, oil, and grease (FOG) deposit formation mechanisms in sewer lines.

    Science.gov (United States)

    He, Xia; Iasmin, Mahbuba; Dean, Lisa O; Lappi, Simon E; Ducoste, Joel J; de los Reyes, Francis L

    2011-05-15

    The presence of hardened and insoluble fats, oil, and grease (FOG) deposits in sewer lines is a major cause of line blockages leading to sanitary sewer overflows (SSOs). Despite the central role that FOG deposits play in SSOs, little is known about the mechanisms of FOG deposit formation in sanitary sewers. In this study, FOG deposits were formed under laboratory conditions from the reaction between free fatty acids and calcium chloride. The calcium and fatty acid profile analysis showed that the laboratory-produced FOG deposit displayed similar characteristics to FOG deposits collected from sanitary sewer lines. Results of FTIR analysis showed that the FOG deposits are metallic salts of fatty acid as revealed by comparisons with FOG deposits collected from sewer lines and pure calcium soaps. Based on the data, we propose that the formation of FOG deposits occurs from the aggregation of excess calcium compressing the double layer of free fatty acid micelles and a saponification reaction between aggregated calcium and free fatty acids.

  18. A mathematical model to predict the effect of heat recovery on the wastewater temperature in sewers.

    Science.gov (United States)

    Dürrenmatt, David J; Wanner, Oskar

    2014-01-01

    Raw wastewater contains considerable amounts of energy that can be recovered by means of a heat pump and a heat exchanger installed in the sewer. The technique is well established, and there are approximately 50 facilities in Switzerland, many of which have been successfully using this technique for years. The planning of new facilities requires predictions of the effect of heat recovery on the wastewater temperature in the sewer because altered wastewater temperatures may cause problems for the biological processes used in wastewater treatment plants and receiving waters. A mathematical model is presented that calculates the discharge in a sewer conduit and the spatial profiles and dynamics of the temperature in the wastewater, sewer headspace, pipe, and surrounding soil. The model was implemented in the simulation program TEMPEST and was used to evaluate measured time series of discharge and temperatures. It was found that the model adequately reproduces the measured data and that the temperature and thermal conductivity of the soil and the distance between the sewer pipe and undisturbed soil are the most sensitive model parameters. The temporary storage of heat in the pipe wall and the exchange of heat between wastewater and the pipe wall are the most important processes for heat transfer. The model can be used as a tool to determine the optimal site for heat recovery and the maximal amount of extractable heat. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Groundwater infiltration, surface water inflow and sewerage exfiltration considering hydrodynamic conditions in sewer systems.

    Science.gov (United States)

    Karpf, Christian; Hoeft, Stefan; Scheffer, Claudia; Fuchs, Lothar; Krebs, Peter

    2011-01-01

    Sewer systems are closely interlinked with groundwater and surface water. Due to leaks and regular openings in the sewer system (e.g. combined sewer overflow structures with sometimes reverse pressure conditions), groundwater infiltration and surface water inflow as well as exfiltration of sewage take place and cannot be avoided. In the paper a new hydrodynamic sewer network modelling approach will be presented, which includes--besides precipitation--hydrographs of groundwater and surface water as essential boundary conditions. The concept of the modelling approach and the models to describe the infiltration, inflow and exfiltration fluxes are described. The model application to the sewerage system of the City of Dresden during a flood event with complex conditions shows that the processes of infiltration, exfiltration and surface water inflows can be described with a higher reliability and accuracy, showing that surface water inflow causes a pronounced system reaction. Further, according to the simulation results, a high sensitivity of exfiltration rates on the in-sewer water levels and a relatively low influence of the dynamic conditions on the infiltration rates were found.

  20. Long-term impacts on sewers following food waste disposer installation in housing areas.

    Science.gov (United States)

    Mattsson, Jonathan; Hedström, Annelie; Viklander, Maria

    2014-01-01

    To increase biogas generation and decrease vehicle transportation of solid waste, the integration of food waste disposers (FWDs) into the wastewater system has been proposed. However, concerns have been raised about the long-term impact of the additional load of the FWDs on sewer systems. To examine the said impact, this study has used closed-circuit television inspection techniques to evaluate the status of 181 concrete pipes serving single family housing areas with a diameter of 225 mm, ranging from a 100% connection rate of households with an FWD to none. A minor study was also performed on a multi-family housing area, where mainly plastic pipes (200 mm) were used. The extent and distribution of deposits related to the ratio of FWDs, inclination and pipe sagging (backfalls) were ascertained by using linear regression and analysis of variance. The results showed that FWDs have had an impact on the level of deposits in the sewer, but this has, in turn, been of minor significance. With a high connection rate of FWDs upstream of a pipe, the extent of the total level of deposits, as well as finer sediments, was statistically determined to be greater. However, the majority of the deposits were observed to be small, which would suggest the impact of FWDs on sewer performance to be minor. As food waste not compatible with the FWD was seen in the sewers, educational campaigns could be beneficial to further lower the risks of sewer blocking.

  1. Hydrocarbon pollution fixed to combined sewer sediment: a case study in Paris.

    Science.gov (United States)

    Rocher, Vincent; Garnaud, Stéphane; Moilleron, Régis; Chebbo, Ghassan

    2004-02-01

    Over a period of two years (2000-2001), sediment samples were extracted from 40 silt traps (STs) spread through the combined sewer system of Paris. All sediment samples were analysed for physico-chemical parameters (pH, organic matter content, grain size distribution), with total hydrocarbons (THs) and 16 polycyclic aromatic hydrocarbons (PAHs) selected from the priority list of the US-EPA. The two main objectives of the study were (1) to determine the hydrocarbon contamination levels in the sediments of the Paris combined sewer system and (2) to investigate the PAH fingerprints in order to assess their spatial variability and to elucidate the PAH origins. The results show that there is some important inter-site and intra-site variations in hydrocarbon contents. Despite this variability, TH and PAH contamination levels (50th percentile) in the Parisian sewer sediment are estimated at 530 and 18 microg g(-1), respectively. The investigation of the aromatic compound distributions in all of the 40 STs has underlined that there is, at the Paris sewer system scale, a homogeneous PAH background pollution. Moreover, the study of the PAH fingerprints, using specific ratios, suggests the predominance of a pyrolytic origin for those PAHs fixed to the sewer sediment.

  2. Current understanding of magnetic storms: Storm-substorm relationships

    International Nuclear Information System (INIS)

    Kamide, Y.; Gonzalez, W.D.; Baumjohann, W.; Daglis, I.A.; Grande, M.; Joselyn, J.A.; Singer, H.J.; McPherron, R.L.; Phillips, J.L.; Reeves, E.G.; Rostoker, G.; Sharma, A.S.; Tsurutani, B.T.

    1998-01-01

    This paper attempts to summarize the current understanding of the storm/substorm relationship by clearing up a considerable amount of controversy and by addressing the question of how solar wind energy is deposited into and is dissipated in the constituent elements that are critical to magnetospheric and ionospheric processes during magnetic storms. (1) Four mechanisms are identified and discussed as the primary causes of enhanced electric fields in the interplanetary medium responsible for geomagnetic storms. It is pointed out that in reality, these four mechanisms, which are not mutually exclusive, but interdependent, interact differently from event to event. Interplanetary coronal mass ejections (ICMEs) and corotating interaction regions (CIRs) are found to be the primary phenomena responsible for the main phase of geomagnetic storms. The other two mechanisms, i.e., HILDCAA (high-intensity, long-duration, continuous auroral electrojet activity) and the so-called Russell-McPherron effect, work to make the ICME and CIR phenomena more geoeffective. The solar cycle dependence of the various sources in creating magnetic storms has yet to be quantitatively understood. (2) A serious controversy exists as to whether the successive occurrence of intense substorms plays a direct role in the energization of ring current particles or whether the enhanced electric field associated with southward IMF enhances the effect of substorm expansions. While most of the Dst variance during magnetic storms can be solely reproduced by changes in the large-scale electric field in the solar wind and the residuals are uncorrelated with substorms, recent satellite observations of the ring current constituents during the main phase of magnetic storms show the importance of ionospheric ions. This implies that ionospheric ions, which are associated with the frequent occurrence of intense substorms, are accelerated upward along magnetic field lines, contributing to the energy density of the

  3. Extreme Precipitation and Emergency Room Visits for Gastrointestinal Illness in Areas With and Without Combined Sewer Systems: An Analysis of Massachusetts Data, 2003-2007

    Science.gov (United States)

    Background: Combined sewer overflows (CSOs) occur in combined sewer systems when sewage and stormwater runoff discharge into waterbodies potentially contaminating water sources. CSOs are often caused by heavy precipitation and are expected to increase with increasing extreme pre...

  4. Stormwater induced input of Pb, Cd, As, Zn and other toxic heavy metals into the sewer system of a region characterized by mining residues. Final report

    International Nuclear Information System (INIS)

    Cichos, C.; Muehle, K.

    1993-06-01

    An estimation of heavy metal transport within the river Freiberger Mulde as well as detailed knowledge about pollutant concentration in sewage sludges, in surface soil and in various mining residues give rise to assume that stormwater induced input especially of As, Pb, Cd and Zn into the sewer system of the town of Freiberg has a significant share of contribution to the high pollution of the river. It is the aim of the project to determine the heavy metal input quantitatively where beside the entire transport above all the main transport ways are to be investigated. In the first period of research reported about a movable monitoring station with rainfall gauge, flow rate meter and automatic sampler had to be supplied. First results of stormwater effects at the main intercepting sewer were discussed on the basis of dry-wether flow. For precipitation intensities of 0.5-1 mm/10 min with 4 to 5fold discharge rates at the maximum the measurements showed about 2 to 6fold dry-wether diurnal loads during a rain wether flow of only one hour. Thus, for the case of flood flow up to 100fold diurnal loads may be expected within an hour. The pollutant transport depends on the intensity of rain and on the duration of dry wether before the rain. Further studies above all apply to the main ways of transport but simultaneously to the entire loads to be measured before the storm sewage overflow. Data to be expected in this way may contribute to a long-term simulation of the sewerage as an important aid for planning storage basins. (orig.) [de

  5. The prevalence of Leptospira sp in sewer rats (Rattus norvegicus)

    DEFF Research Database (Denmark)

    Krøigaard, Louise; Villumsen, Steen; Markussen, Mette Drude

    Test). Preliminary results based on one fourth of the captured rats indicate, that the prevalence of pathogenic leptospira infected sewer rats are relatively high, as 28 out 48 rats were positive by PCR. This suggests that the sewer could be an environment representing high prevalence of leptospira...... among rats and thus an environment with high risk of transmission....

  6. Controlling sewer systems – a critical review based on systems in three EU cities

    DEFF Research Database (Denmark)

    Mollerup, Ane Loft; Mikkelsen, Peter Steen; Thornberg, D.

    2017-01-01

    The term Real Time Control (RTC) is widely used to describe all types of control systems in sewer systems. Today the term covers everything from the simplest to the most advanced types of control systems, making it difficult to communicate about sewer system control in a precise manner, as well...... as search and find specific types of control systems for comparison. Through a survey of implemented control systems in three EU cities today and with the perspectives of current research within the field of sewer system control, the needs for a new control system design framework is identified....... With the basis of existing frameworks for control system design, a new time-scale dependent framework is proposed. We believe this comprehensive time-scale dependent framework can help water utilities to retrofit and design new control solutions and facilitate knowledge sharing about existing designs....

  7. Modelling Illicit Drug Fate in Sewers for Wastewater-Based Epidemiology

    DEFF Research Database (Denmark)

    Ramin, Pedram

    was found during festival period as compared to normal weekdays. Wastewater-based epidemiology is a truly interdisciplinary approach in which engineering tools, including models developed and tested in this thesis, can be beneficial for the accurate estimation of drug consumption in urban areas........ Sewer systems can be considered as biological reactors, in which the concentration of organic chemicals present in wastewater can be impacted by in-sewer processes during hydraulic residence time. Illicit drug biomarkers, as trace organic chemicals in the range of nanograms to micrograms per liter...... on sorption and transformation of drug biomarkers in raw wastewater and sewer biofilms; and (ii) developing modelling tools – by combining and extending existing modelling frameworks – to predict such processes. To achieve this goal, a substantial part of this thesis was dedicated to the experimental...

  8. Measurement of infiltration rates in urban sewer systems by use of oxygen isotopes.

    Science.gov (United States)

    De Bénédittis, J; Bertrand-Krajewski, J L

    2005-01-01

    The paper presents the principle of a method to measure infiltration rates in sewer systems based on the use of oxygen isotopes and its application in Lyon (France). In the urban area of Lyon, significant differences in delta 18O that can reach 3 per thousand are observed between the oxygen isotopic compositions of groundwater originating from Rhone, Saone and from their associated alluvial aquifers. Drinking water supplying Lyon results mainly from pumping in the Rhone alluvial aquifer. Therefore, in some areas, the difference of isotopic composition between wastewater resulting from the consumption of drinking water and local groundwater can be used to measure infiltration in sewer systems. The application in the catchment of Ecully shows that the infiltration flow rate presents strong fluctuations at an hourly scale: it varies between 15 and 40 m3/h. This variability could be explained by non-constant discharges of pumping and by variations of the water level in the sewer.

  9. Coordinated management of combined sewer overflows by means of environmental decision support systems.

    Science.gov (United States)

    Murla, Damian; Gutierrez, Oriol; Martinez, Montse; Suñer, David; Malgrat, Pere; Poch, Manel

    2016-04-15

    During heavy rainfall, the capacity of sewer systems and wastewater treatment plants may be surcharged producing uncontrolled wastewater discharges and a depletion of the environmental quality. Therefore there is a need of advanced management tools to tackle with these complex problems. In this paper an environmental decision support system (EDSS), based on the integration of mathematical modeling and knowledge-based systems, has been developed for the coordinated management of urban wastewater systems (UWS) to control and minimize uncontrolled wastewater spills. Effectiveness of the EDSS has been tested in a specially designed virtual UWS, including two sewers systems, two WWTP and one river subjected to typical Mediterranean rain conditions. Results show that sewer systems, retention tanks and wastewater treatment plants improve their performance under wet weather conditions and that EDSS can be very effective tools to improve the management and prevent the system from possible uncontrolled wastewater discharges. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Application of Morphological Segmentation to Leaking Defect Detection in Sewer Pipelines

    Directory of Open Access Journals (Sweden)

    Tung-Ching Su

    2014-05-01

    Full Text Available As one of major underground pipelines, sewerage is an important infrastructure in any modern city. The most common problem occurring in sewerage is leaking, whose position and failure level is typically identified through closed circuit television (CCTV inspection in order to facilitate rehabilitation process. This paper proposes a novel method of computer vision, morphological segmentation based on edge detection (MSED, to assist inspectors in detecting pipeline defects in CCTV inspection images. In addition to MSED, other mathematical morphology-based image segmentation methods, including opening top-hat operation (OTHO and closing bottom-hat operation (CBHO, were also applied to the defect detection in vitrified clay sewer pipelines. The CCTV inspection images of the sewer system in the 9th district, Taichung City, Taiwan were selected as the experimental materials. The segmentation results demonstrate that MSED and OTHO are useful for the detection of cracks and open joints, respectively, which are the typical leakage defects found in sewer pipelines.

  11. A methodological approach to the design of optimising control strategies for sewer systems

    DEFF Research Database (Denmark)

    Mollerup, Ane Loft; Mikkelsen, Peter Steen; Sin, Gürkan

    2016-01-01

    This study focuses on designing an optimisation based control for sewer system in a methodological way and linking itto a regulatory control. Optimisation based design is found to depend on proper choice of a model, formulation of objective function and tuning of optimisation parameters. Accordin......This study focuses on designing an optimisation based control for sewer system in a methodological way and linking itto a regulatory control. Optimisation based design is found to depend on proper choice of a model, formulation of objective function and tuning of optimisation parameters....... Accordingly, two novel optimisation configurations are developed, where the optimisation either acts on the actuators or acts on the regulatory control layer. These two optimisation designs are evaluated on a sub-catchment of the sewer system in Copenhagen, and found to perform better than the existing...

  12. Design and Development of Vision Based Blockage Clearance Robot for Sewer Pipes

    Directory of Open Access Journals (Sweden)

    Krishna Prasad Nesaian

    2012-03-01

    Full Text Available Robotic technology is one of the advanced technologies, which is capable of completing tasks at situations where humans are unable to reach, see or survive. The underground sewer pipelines are the major tools for the transportation of effluent water. A lot of troubles caused by blockage in sewer pipe will lead to overflow of effluent water, sanitation problems. So robotic vehicle that is capable of traveling at underneath effluent water determining blockage using ultrasonic sensors and clearing by means of drilling mechanism is done. In addition to that wireless camera is fixed which acts as a robot vision by which we can monitor video and capture images using MATLAB tool. Thus in this project a prototype model of underground sewer pipe blockage clearance robot with drilling type will be developed

  13. Tormenta tiroidea Thyroid storm

    Directory of Open Access Journals (Sweden)

    Lisette Leal Curí

    2012-12-01

    Full Text Available La tormenta tiroidea es una de las situaciones más críticas entre las emergencias endocrinas y tiene una significativa mortalidad. La etiología más común de tirotoxicosis es la enfermedad de Graves y el factor precipitante que predomina es la infección. Clínicamente se caracteriza por la disfunción de varios sistemas (termorregulador, nervioso central, gastrointestinal y cardiovascular, con niveles de hormonas tiroideas libres o totales por encima de los valores normales. El tratamiento debe tener un enfoque multidisciplinario, e incluye medidas de soporte en unidades de cuidados intensivos, normalización de la temperatura corporal, reducción de la producción y liberación de hormonas tiroideas, con antitiroideos de síntesis y yodo respectivamente, bloqueo de los efectos periféricos mediante la administración de beta-bloqueadores, y corrección del factor desencadenante. Una vez que el paciente se encuentra estable es necesario planificar una terapia definitiva que impida la recurrencia futura de la crisis tirotóxica.The thyroid storm is one of the most critical situations in the endocrine emergencies and exhibits a significant mortality rate. The most common etiology of thyrotoxicosis is Graves' disease and the predominant precipitating factor is infection. The clinical characteristics are dysfunction of several systems (heat-regulator, central nervous, gastrointestinal and cardiovascular, and levels of total or free thyroid hormones that exceed the normal values. The treatment must be multidisciplinary and include support measures in intensive care units, normalization of body temperature, reduction of the production and the release of thyroid hormones by using synthesis and iodine anti-thyroid products respectively, blockade of the peripheral effects through administration of Beta-blockers and correction of the unleashing factor. Once the patients are stabilized, it is necessary to plan the final therapy that will prevent the

  14. Critical review on the stability of illicit drugs in sewers and wastewater samples.

    Science.gov (United States)

    McCall, Ann-Kathrin; Bade, Richard; Kinyua, Juliet; Lai, Foon Yin; Thai, Phong K; Covaci, Adrian; Bijlsma, Lubertus; van Nuijs, Alexander L N; Ort, Christoph

    2016-01-01

    Wastewater-based epidemiology (WBE) applies advanced analytical methods to quantify drug residues in wastewater with the aim to estimate illicit drug use at the population level. Transformation processes during transport in sewers (chemical and biological reactors) and storage of wastewater samples before analysis are expected to change concentrations of different drugs to varying degrees. Ignoring transformation for drugs with low to medium stability will lead to an unknown degree of systematic under- or overestimation of drug use, which should be avoided. This review aims to summarize the current knowledge related to the stability of commonly investigated drugs and, furthermore, suggest a more effective approach to future experiments. From over 100 WBE studies, around 50 mentioned the importance of stability and 24 included tests in wastewater. Most focused on in-sample stability (i.e., sample preparation, preservation and storage) and some extrapolated to in-sewer stability (i.e., during transport in real sewers). While consistent results were reported for rather stable compounds (e.g., MDMA and methamphetamine), a varying range of stability under different or similar conditions was observed for other compounds (e.g., cocaine, amphetamine and morphine). Wastewater composition can vary considerably over time, and different conditions prevail in different sewer systems. In summary, this indicates that more systematic studies are needed to: i) cover the range of possible conditions in sewers and ii) compare results more objectively. To facilitate the latter, we propose a set of parameters that should be reported for in-sewer stability experiments. Finally, a best practice of sample collection, preservation, and preparation before analysis is suggested in order to minimize transformation during these steps. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Fat, oil and grease deposits in sewers: characterisation of deposits and formation mechanisms.

    Science.gov (United States)

    Williams, J B; Clarkson, C; Mant, C; Drinkwater, A; May, E

    2012-12-01

    Fat, oil and grease deposits (FOG) in sewers are a major problem and can cause sewer overflows, resulting in environmental damage and health risks. Often simplistically portrayed as cooling of fats, recent research has suggested that saponification may be involved in FOG formation. However there are still questions about the mechanisms effecting transformations in sewers and the role and source of metal cations involved in saponification. This study characterises FOG deposits from pumping stations, sewers and sewage works from different water hardness zones across the UK. The sites all had previous problems with FOG and most catchments contained catering and food preparation establishments. The FOG deposits were highly variable with moisture content ranging from 15 to 95% and oil content from 0 to 548 mg/g. Generally the pumping stations had lower moisture content and higher fat content, followed by the sewers then the sewage works. The water in contact with the FOG had high levels of oil (mean of about 800 mg/L) and this may indicate poor kitchen FOG management practices. FOG fatty acid profiles showed a transformation from unsaturated to saturated forms compared to typical cooking oils. This seems to relate to ageing in the sewer network or the mechanism of formation, as samples from pumping stations had higher proportions of C18:1 compared to C16. This may be due to microbial transformations by bacteria such as Clostridium sp. in a similar process to adipocere formation. There was an association between water hardness and increased Ca levels in FOG along with harder deposits and higher melting points. A link between FOG properties and water hardness has not been previously reported for field samples. This may also be due to microbial processes, such as biocalcification. By developing the understanding of these mechanisms it may be possible to more effectively control FOG deposits, especially when combined with promotion of behavioural change. Copyright © 2012

  16. Uncovering the secret lives of sewer rats (Rattus norvegicus): Movements, distribution and population dynamics revealed by a capture-mark-recapture study

    DEFF Research Database (Denmark)

    Heiberg, Ann-Charlotte; Sluydts, Vincent; Leirs, Herwig E.l.

    2012-01-01

    Context.: In many parts of the world, brown rats have colonised sewer systems and the rat populations in sewers are often thought to be a source of problems with rats on the surface. The management of sewer rat populations is usually performed with little, if any, knowledge of the dynamics and be...

  17. Catchment & sewer network simulation model to benchmark control strategies within urban wastewater systems

    DEFF Research Database (Denmark)

    Saagi, Ramesh; Flores Alsina, Xavier; Fu, Guangtao

    2016-01-01

    This paper aims at developing a benchmark simulation model to evaluate control strategies for the urban catchment and sewer network. Various modules describing wastewater generation in the catchment, its subsequent transport and storage in the sewer system are presented. Global/local overflow based...... evaluation criteria describing the cumulative and acute effects are presented. Simulation results show that the proposed set of models is capable of generating daily, weekly and seasonal variations as well as describing the effect of rain events on wastewater characteristics. Two sets of case studies...

  18. Kinetics of aerobic oxidation of volatile sulfur compounds in wastewater and biofilm from sewers

    DEFF Research Database (Denmark)

    Rudelle, Elise Alice; Vollertsen, Jes; Hvitved-Jacobsen, Thorkild

    2013-01-01

    Laboratory experiments were conducted to investigate the kinetics of aerobic chemical and biological oxidation of selected odorous volatile sulfur compounds (VSCs) by wastewater and biofilm from sewers. The VSCs included methyl mercaptan (MeSH), ethyl mercaptan (EtSH), dimethyl sulfide (DMS......-spot downstream of a force main and the other was a gravity sewer transporting young aerobic wastewater. The kinetics of VSC oxidation for both wastewater and suspended biofilm samples followed a first-order rate equation. The average values of the reaction rate constants demonstrated the following order...... in the aerobic wastewater....

  19. Water sensitive urban design retrofits in Copenhagen - 40% to the sewer, 60% to the city

    DEFF Research Database (Denmark)

    Fryd, O.; Backhaus, Antje; Birch, Heidi

    2013-01-01

    Water Sensitive Urban Design (WSUD) is emerging in Denmark. This interdisciplinary desk study investigated the options for WSUD retrofitting in a 15 km(2) combined sewer catchment area in Copenhagen. The study was developed in collaboration with the City of Copenhagen and its water utility......, neighbourhoods located near low-lying streams and public parks are disconnected from the sewer system and the sloping terrain is utilised to convey runoff. Fourth, the promotion of coherent blue and green wedges in the city is linked with WSUD retrofits and urban climate-proofing. Fifth, WSUD is implemented...

  20. Release of hydrogen sulfide in a sewer system under intermittent flow conditions

    DEFF Research Database (Denmark)

    Matias, Natércia; Matos, Rita Ventura; Ferreira, Filipa

    2017-01-01

    The presence and fate of hydrogen sulfide in wastewater systems were studied in two stretches of an intercepting sewer system located in a coastal village, in Portugal. A range of hydraulic parameters were obtained and liquid and gas phase measurements were carried out, both continuously and thro......The presence and fate of hydrogen sulfide in wastewater systems were studied in two stretches of an intercepting sewer system located in a coastal village, in Portugal. A range of hydraulic parameters were obtained and liquid and gas phase measurements were carried out, both continuously...... authors’ publications addressing relatively small pipes and moderate water flows....

  1. Space storms as natural hazards

    Directory of Open Access Journals (Sweden)

    L. I. Dorman

    2008-04-01

    Full Text Available Eruptive activity of the Sun produces a chain of extreme geophysical events: high-speed solar wind, magnetic field disturbances in the interplanetary space and in the geomagnetic field and also intense fluxes of energetic particles. Space storms can potentially destroy spacecrafts, adversely affect astronauts and airline crew and human health on the Earth, lead to pipeline breaking, melt electricity transformers, and discontinue transmission. In this paper we deal with two consequences of space storms: (i rise in failures in the operation of railway devices and (ii rise in myocardial infarction and stroke incidences.

  2. Patterns of Storm Injury and Tree Response

    Science.gov (United States)

    Kevin Smith; Walter Shortle; Kenneth Dudzik

    2001-01-01

    The ice storm of January 1998 in the northeastern United States and adjacent Canada was an extreme example of severe weather that injures trees every year. Broken branches, split branch forks, and snapped stems are all examples of storm injury.

  3. Storm Water Management Model (SWMM)

    Science.gov (United States)

    Stormwater discharges continue to cause impairment of our Nation’s waterbodies. Regulations that require the retention and/or treatment of frequent, small storms that dominate runoff volumes and pollutant loads are becoming more common. The U.S. Environmental Protection Agency (E...

  4. Stochastic Optical Reconstruction Microscopy (STORM).

    Science.gov (United States)

    Xu, Jianquan; Ma, Hongqiang; Liu, Yang

    2017-07-05

    Super-resolution (SR) fluorescence microscopy, a class of optical microscopy techniques at a spatial resolution below the diffraction limit, has revolutionized the way we study biology, as recognized by the Nobel Prize in Chemistry in 2014. Stochastic optical reconstruction microscopy (STORM), a widely used SR technique, is based on the principle of single molecule localization. STORM routinely achieves a spatial resolution of 20 to 30 nm, a ten-fold improvement compared to conventional optical microscopy. Among all SR techniques, STORM offers a high spatial resolution with simple optical instrumentation and standard organic fluorescent dyes, but it is also prone to image artifacts and degraded image resolution due to improper sample preparation or imaging conditions. It requires careful optimization of all three aspects-sample preparation, image acquisition, and image reconstruction-to ensure a high-quality STORM image, which will be extensively discussed in this unit. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  5. Shoreline resilience to individual storms and storm clusters on a meso-macrotidal barred beach

    NARCIS (Netherlands)

    Angnuureng, Donatus Bapentire; Almar, Rafael; Senechal, Nadia; Castelle, Bruno; Addo, Kwasi Appeaning; Marieu, Vincent; Ranasinghe, Roshanka

    2017-01-01

    This study investigates the impact of individual storms and storm clusters on shoreline recovery for the meso-to macrotidal, barred Biscarrosse beach in SW France, using 6 years of daily video observations. While the study area experienced 60 storms during the 6-year study period, only 36 storms

  6. A review of best practice in relation to iodine-131 ablation discharges to sewer

    International Nuclear Information System (INIS)

    Punt, A.; Kruse, P.; Smith, K

    2010-03-01

    This report was produced by Enviros Consulting Ltd under contract to the RPII. It presents a review of best practice in relation to the management of iodine-131 ablation discharges to sewer and recommends a waste management strategy that could be adopted in the Republic of Ireland

  7. The use and disposal of greywater in the non-sewered areas of ...

    African Journals Online (AJOL)

    The main aim of this study was to investigate the use and disposal of greywater in non-sewered areas in South Africa and this included developing options for the management thereof, both in terms of reducing health and environmental risks as well as possibly providing benefits through controlled reuse. This paper reports ...

  8. Control of Sewer systems and Wastewater treatment plants using pollutant concentration profiles

    DEFF Research Database (Denmark)

    Bechmann, Henrik; Nielsen, Marinus K.; Madsen, Henrik

    1998-01-01

    On-line measurements of pollutants in the wastewater combined with grey-box modelling are used to estimate the amount of deposits in the sewer system. The pollutant mass flow at the wastewater treatment plant is found to consist of a diurnal profile minus the deposited amount of pollutants...

  9. Functional evaluation of pollutant transformation in sediment from combined sewer system.

    Science.gov (United States)

    Shi, Xuan; Ngo, Huu Hao; Sang, Langtao; Jin, Pengkang; Wang, Xiaochang C; Wang, Guanghua

    2018-07-01

    In this study, a pilot combined sewer system was constructed to characterize the pollutant transformation in sewer sediment. The results showed that particulate contaminants deposited from sewage could be transformed into dissolved matter by distinct pollutant transformation pathways. Although the oxidation-reduction potential (ORP) was varied from -80 mV to -340 mV in different region of the sediment, the fermentation was the dominant process in all regions of the sediment, which induced hydrolysis and decomposition of particulate contaminants. As a result, the accumulation of dissolved organic matter and the variation of ORP values along the sediment depth led to the depth-dependent reproduction characteristics of methanogens and sulfate-reducing bacteria, which were existed in the middle and deep layer of the sediment respectively. However, the diversity of nitrifying and polyphosphate-accumulating bacteria was low in sewer sediment and those microbial communities showed a non-significant correlation with nitrogen and phosphorus contaminants, which indicated that the enrichment of nitrogen and phosphorus contaminants was mainly caused by physical deposition process. Thus, this study proposed a promising pathway to evaluate pollutant transformation and can help provide theoretical foundation for urban sewer improvement. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. High-Rate Disinfection Techniques for Combined Sewer Overflow (Proceedings Paper)

    Science.gov (United States)

    This paper presents high-rate disinfection technologies for combined sewer overflow (CSO). The high-rate disinfection technologies of interest are: chlorination/dechlorination, ultraviolet light irradiation (UV), chlorine dioxide (ClO2 ), ozone (O3), peracetic acid (CH3COOOH ), a...

  11. Monitoring the Startup of a Sacrificial Concrete Sewer for Odor Control

    DEFF Research Database (Denmark)

    Nielsen, Asbjørn Haaning; Vollertsen, Jes

    2014-01-01

    with extended retention time. For the purpose of the study, a 50-m long sacrificial concrete gravity sewer was constructed using a high alkalinity concrete pipe. The monitoring campaign reported in this paper covers the first 9 months of operation. The results clearly demonstrate the ability of the system...

  12. Vision-based system for the control and measurement of wastewater flow rate in sewer systems.

    Science.gov (United States)

    Nguyen, L S; Schaeli, B; Sage, D; Kayal, S; Jeanbourquin, D; Barry, D A; Rossi, L

    2009-01-01

    Combined sewer overflows and stormwater discharges represent an important source of contamination to the environment. However, the harsh environment inside sewers and particular hydraulic conditions during rain events reduce the reliability of traditional flow measurement probes. In the following, we present and evaluate an in situ system for the monitoring of water flow in sewers based on video images. This paper focuses on the measurement of the water level based on image-processing techniques. The developed image-based water level algorithms identify the wall/water interface from sewer images and measure its position with respect to real world coordinates. A web-based user interface and a 3-tier system architecture enable the remote configuration of the cameras and the image-processing algorithms. Images acquired and processed by our system were found to reliably measure water levels and thereby to provide crucial information leading to better understand particular hydraulic behaviors. In terms of robustness and accuracy, the water level algorithm provided equal or better results compared to traditional water level probes in three different in situ configurations.

  13. Output-feedback control of combined sewer networks through receding horizon control with moving horizon estimation

    Science.gov (United States)

    Joseph-Duran, Bernat; Ocampo-Martinez, Carlos; Cembrano, Gabriela

    2015-10-01

    An output-feedback control strategy for pollution mitigation in combined sewer networks is presented. The proposed strategy provides means to apply model-based predictive control to large-scale sewer networks, in-spite of the lack of measurements at most of the network sewers. In previous works, the authors presented a hybrid linear control-oriented model for sewer networks together with the formulation of Optimal Control Problems (OCP) and State Estimation Problems (SEP). By iteratively solving these problems, preliminary Receding Horizon Control with Moving Horizon Estimation (RHC/MHE) results, based on flow measurements, were also obtained. In this work, the RHC/MHE algorithm has been extended to take into account both flow and water level measurements and the resulting control loop has been extensively simulated to assess the system performance according different measurement availability scenarios and rain events. All simulations have been carried out using a detailed physically based model of a real case-study network as virtual reality.

  14. Bayesian analysis for erosion modelling of sediments in combined sewer systems.

    Science.gov (United States)

    Kanso, A; Chebbo, G; Tassin, B

    2005-01-01

    Previous research has confirmed that the sediments at the bed of combined sewer systems are the main source of particulate and organic pollution during rain events contributing to combined sewer overflows. However, existing urban stormwater models utilize inappropriate sediment transport formulas initially developed from alluvial hydrodynamics. Recently, a model has been formulated and profoundly assessed based on laboratory experiments to simulate the erosion of sediments in sewer pipes taking into account the increase in strength with depth in the weak layer of deposits. In order to objectively evaluate this model, this paper presents a Bayesian analysis of the model using field data collected in sewer pipes in Paris under known hydraulic conditions. The test has been performed using a MCMC sampling method for calibration and uncertainty assessment. Results demonstrate the capacity of the model to reproduce erosion as a direct response to the increase in bed shear stress. This is due to the model description of the erosional strength in the deposits and to the shape of the measured bed shear stress. However, large uncertainties in some of the model parameters suggest that the model could be over-parameterised and necessitates a large amount of informative data for its calibration.

  15. COMPUTER MODEL ANALYSIS FOR MITIGATION PLANNING OF SANITARY-SEWER OVERFLOWS

    Science.gov (United States)

    Sanitary sewer overflows (SSOs) are generally difficult to witness or document as they usually occur during rain events when people are indoors or out of sight. To anser where and when an SSO may occur, it is necessary to know the flow conveyance capacity at various parts of the ...

  16. NORTH PORTAL-SANITARY SEWER CALCULATION-SHOP BUILDING No.5006

    International Nuclear Information System (INIS)

    S. Blackstone

    1996-01-01

    The purpose of this design calculation is to determine the demand on the waste system and to size the sanitary sewer line serving the Shop Building No.5006 in accordance with the Uniform Plumbing Code (Section 4.4.1) and US Department of Energy Order 6430.1A-1540 (Section 4.4.2)

  17. Mechanisms of fat, oil and grease (FOG) deposit formation in sewer lines.

    Science.gov (United States)

    He, Xia; de los Reyes, Francis L; Leming, Michael L; Dean, Lisa O; Lappi, Simon E; Ducoste, Joel J

    2013-09-01

    FOG deposits in sewer systems have recently been shown to be metallic salts of fatty acids. However, the fate and transport of FOG deposit reactant constituents and the complex interactions during the FOG deposit formation process are still largely unknown. In this study, batch tests were performed to elucidate the mechanisms of FOG deposit formation that lead to sanitary sewer overflows (SSOs). We report the first formation of FOG deposits on a concrete surface under laboratory conditions that mimic the formation of deposits in sewer systems. Results showed that calcium, the dominant metal in FOG deposits, can be released from concrete surfaces under low pH conditions and contribute to the formation process. Small amounts of additional oil to grease interceptor effluent substantially facilitated the air/water or pipe surface/water interfacial reaction between free fatty acids and calcium to produce surface FOG deposits. Tests of different fatty acids revealed that more viscous FOG deposit solids were formed on concrete surfaces, and concrete corrosion was accelerated, in the presence of unsaturated FFAs versus saturated FFAs. Based on all the data, a comprehensive model was proposed for the mechanisms of FOG deposit formation in sewer systems. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Sulfide-iron interactions in domestic wastewater from a gravity sewer

    NARCIS (Netherlands)

    Nielsen, A.H.; Lens, P.N.L.; Vollertsen, J.; Hvitved-Jacobsen, Th.

    2005-01-01

    Interactions between iron and sulfide in domestic wastewater from a gravity sewer were investigated with particular emphasis on redox cycling of iron and iron sulfide formation. The concentration ranges of iron and total sulfide in the experiments were 0.4-5.4 mg Fe L-1 and 0-5.1 mg S L-1,

  19. 76 FR 35215 - Notice of EPA Workshop on Sanitary Sewer Overflows and Peak Wet Weather Discharges

    Science.gov (United States)

    2011-06-16

    ... maintained sanitary sewer systems are meant to collect and transport all of the sewage that flows into them... sewage from these overflows can contaminate our waters, causing serious water quality problems. It can... influent flows to exceed the treatment capacity of existing secondary treatment units. Known as ``peak...

  20. Modelling sewer sediment deposition, erosion, and transport processes to predict acute influent and reduce combined sewer overflows and CO(2) emissions.

    Science.gov (United States)

    Mouri, Goro; Oki, Taikan

    2010-01-01

    Understanding of solids deposition, erosion, and transport processes in sewer systems has improved considerably in the past decade. This has provided guidance for controlling sewer solids and associated acute pollutants to protect the environment and improve the operation of wastewater systems. Although measures to decrease combined sewer overflow (CSO) events have reduced the amount of discharged pollution, overflows continue to occur during rainy weather in combined sewer systems. The solution lies in the amount of water allotted to various processes in an effluent treatment system, in impact evaluation of water quality and prediction technology, and in stressing the importance of developing a control technology. Extremely contaminated inflow has been a serious research subject, especially in connection with the influence of rainy weather on nitrogen and organic matter removal efficiency in wastewater treatment plants (WWTP). An intensive investigation of an extremely polluted inflow load to WWTP during rainy weather was conducted in the city of Matsuyama, the region used for the present research on total suspended solid (TSS) concentration. Since the inflow during rainy weather can be as much as 400 times that in dry weather, almost all sewers are unsettled and overflowing when a rain event is more than moderate. Another concern is the energy consumed by wastewater treatment; this problem has become important from the viewpoint of reducing CO(2) emissions and overall costs. Therefore, while establishing a prediction technology for the inflow water quality characteristics of a sewage disposal plant is an important priority, the development of a management/control method for an effluent treatment system that minimises energy consumption and CO(2) emissions due to water disposal is also a pressing research topic with regards to the quality of treated water. The procedure to improve water quality must make use of not only water quality and biotic criteria, but also

  1. 46 CFR 108.221 - Storm rails.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Storm rails. 108.221 Section 108.221 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Construction and Arrangement Rails § 108.221 Storm rails. Each unit must have a storm rail in the following...

  2. 46 CFR 169.329 - Storm rails.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Storm rails. 169.329 Section 169.329 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Construction and Arrangement Rails and Guards § 169.329 Storm rails. Suitable storm rails or hand grabs must be...

  3. Er Storm P. en hardcore vagabond?

    DEFF Research Database (Denmark)

    Sortkær, Allan

    2002-01-01

    Den vagabond, som vi kender som Storm P.s, er ikke en figur, der kom fra en guddommelig inspiration eller deslige. Den var en allerede velkendt figur, før Storm P. tog den til sig, og figuren gennemgik radikale forandringer gennem Storm P.s liv: Krads social satire, hypervoldelig eller hyggelig...

  4. 46 CFR 116.920 - Storm rails.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Storm rails. 116.920 Section 116.920 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... and Guards § 116.920 Storm rails. Suitable storm rails or hand grabs must be installed where necessary...

  5. 46 CFR 177.920 - Storm rails.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Storm rails. 177.920 Section 177.920 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) CONSTRUCTION AND ARRANGEMENT Rails and Guards § 177.920 Storm rails. Suitable storm rails or hand grabs must be...

  6. 46 CFR 127.320 - Storm rails.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Storm rails. 127.320 Section 127.320 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS CONSTRUCTION AND ARRANGEMENTS Rails and Guards § 127.320 Storm rails. Suitable storm rails must be installed in each passageway and at...

  7. Transformation of AgCl nanoparticles in a sewer system — A field study

    Energy Technology Data Exchange (ETDEWEB)

    Kaegi, Ralf, E-mail: ralf.kaegi@eawag.ch [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Überlandstrasse 133, 8600 Dübendorf (Switzerland); Voegelin, Andreas; Sinnet, Brian [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Überlandstrasse 133, 8600 Dübendorf (Switzerland); Zuleeg, Steffen [KUSTER + HAGER Group, Oberstrasse 222, 9014 St. Gallen (Switzerland); Siegrist, Hansruedi [Eawag, Swiss Federal Institute of Aquatic Science and Technology, Überlandstrasse 133, 8600 Dübendorf (Switzerland); Burkhardt, Michael [HSR University of Applied Sciences, Institute of Environmental and Process Engineering (UMTEC), Oberseestrasse 10, 8640 Rapperswil (Switzerland)

    2015-12-01

    Silver nanoparticles (Ag-NP) are increasingly used in consumer products and their release during the use phase may negatively affect aquatic ecosystems. Research efforts, so far, have mainly addressed the application and use of metallic Ag(0)-NP. However, as shown by recent studies on the release of Ag from textiles, other forms of Ag, especially silver chloride (AgCl), are released in much larger quantities than metallic Ag(0). In this field study, we report the release of AgCl-NP from a point source (industrial laundry that applied AgCl-NP during a piloting phase over a period of several months to protect textiles from bacterial regrowth) to the public sewer system and investigate the transformation of Ag during its transport in the sewer system and in the municipal wastewater treatment plant (WWTP). During the study period, the laundry discharged ~ 85 g of Ag per day, which dominated the Ag loads in the sewer system from the respective catchment (72–95%) and the Ag in the digested WWTP sludge (67%). Combined results from electron microscopy and X-ray absorption spectroscopy revealed that the Ag discharged from the laundry to the sewer consisted of about one third AgCl and two thirds Ag{sub 2}S, both forms primarily occurring as nanoparticles with diameters < 100 nm. During the 800 m transport in the sewer channel to the nearby WWTP, corresponding to a travel time of ~ 30 min, the remaining AgCl was transformed into nanoparticulate Ag{sub 2}S. Ag{sub 2}S-NP also dominated the Ag speciation in the digested sludge. In line with results from earlier studies, the very low Ag concentrations measured in the effluent of the WWTP (< 0.5 μg L{sup −1}) confirmed the very high removal efficiency of Ag from the wastewater stream (> 95%). - Highlights: • First field study on the transformation of AgCl nanoparticles released from a point source into the municipal sewer system. • Transformation of AgCl-NP into Ag{sub 2}S already occurred during 30-min transport in the

  8. Development of VLF noise storm and its relation to dynamics of magnetosphere during geomagnetic storms

    International Nuclear Information System (INIS)

    Fedyakina, N.I.; Khorosheva, O.V.

    1989-01-01

    Dependence between the development of geomagnetic storm and VLF noise storm is studied. Two conditions should be met for the development of noise storm in VLF-hiss (f ≅ 0.5-10 kHz): a) threshold intensity of electron fluxes with E e > 40 keV in plasma layers; b) the presence of substorms resulting to widening of electron belt and its collision with cold plasma of plasmasphere. The noise storm at the fixed longitude begins about midnight independently of the phase of magnetic storm; Noise storm duration is connected with geomagnetic storm intensity by direct linear relationship

  9. Sewer slime analysis as a method of spotting heavy metal bearing waste water discharge. Sielhautuntersuchungen zur Einkreisung schwermetallhaltiger Einleitungen

    Energy Technology Data Exchange (ETDEWEB)

    Gutekunst, B.

    1988-01-01

    The sewer slime method, in analogy to sediment analyses, informs about the discharges which are polluted with heavy metals and fed into the public sewage system at specific points, independent of the time of discharge. The sewer slime consisting of bacteria, fungi, organic and inorganic compounds concentrates heavy metals by sedimentation, adsorption and precipitation processes and thus represents a pollution indicator. This study characterizes sewer slimes by means of physical properties and by analysis of the chemical and biological composition. The mechanisms of heavy metal enrichment and reduction under altered environmental conditions are analyzed using the elements Pb, Cd, Cu, Ni and Zn as examples. (RB).

  10. A generic methodology for the optimisation of sewer systems using stochastic programming and self-optimizing control

    DEFF Research Database (Denmark)

    Maurico-Iglesias, Miguel; Castro, Ignacio Montero; Mollerup, Ane Loft

    2015-01-01

    . Such controller is aimed at keeping the system close to the optimal performance, thanks to an optimal selection of controlled variables. The definition of an optimal performance was carried out by a two-stage optimisation (stochastic and deterministic) to take into account both the overflow during the current......The design of sewer system control is a complex task given the large size of the sewer networks, the transient dynamics of the water flow and the stochastic nature of rainfall. This contribution presents a generic methodology for the design of a self-optimising controller in sewer systems...

  11. Resilience of sewage services to climate change uncertainty: analysis of the management of sewer overflows in two Parisian suburban areas.

    Science.gov (United States)

    Rioust, E.; Deroubaix, J. F.; Barroca, B.; Bonierbale, T.; de Gouvello, B.; Deutsch, J. C.; Hubert, G.

    2009-04-01

    This paper considers the resilience perspective as an approach for understanding social and political vulnerabilities of urban services. The authors examine to what extend uncertainty due to climate change may affect the resilience of these urban services. The resilience perspective is increasingly used for analysing social groups' capacities to adapt to and live with disturbances. A lot of work on resilience has focused on the capacity to absorb shocks and still maintain functions. But there is also another aspect of resilience, which leads to take into account systems vulnerabilities and to aim at understanding their equilibrium and re-organization capacity. The purpose with this paper is to assess sewage systems capacities to adapt to climate change. Indeed, climate change could cause an increase of extreme rain events and, as a matter of consequence, an increase of sewer overflows and flooding of urbanised areas. Sewer systems have to cope with this change that may gravely affect urban planning. In recent studies of political science, risk management has been considered as a public policy involving and resulting from complex social, political and technical processes (Gilbert et al. 2003). From this point of view, the management of wastewaters and storm waters has to be considered not only as a technical but also as a political and a social system. Therefore, political science can be a fruitful perspective to understand the stakeholders perceptions of uncertainty and the way they are going to integrate this issue in their practices. The authors analyse the adaptive capacities of two sewer systems located in the Parisian suburban area. The chosen areas are highly populated. Each network is managed within a political and administrative unit called "Département". Both authorities of these "Départements" implement a public sewage service. Nonetheless these networks are connected and part of the greater Paris sewage policy. In both areas a real time control of

  12. [Diagnosis and treatment of thyroid storm].

    Science.gov (United States)

    Akamizu, Takashi

    2012-11-01

    Thyrotoxic storm is a life-threatening condition requiring emergency treatment. Neither its epidemiological data nor diagnostic criteria have been fully established. We clarified the clinical and epidemiological characteristics of thyroid storm using nationwide surveys and then formulate diagnostic criteria for thyroid storm. To perform the nationwide survey on thyroid storm, we first developed tentative diagnostic criteria for thyroid storm, mainly based upon the literature (the first edition). We analyzed the relationship of the major features of thyroid storm to mortality and to certain other features. Finally, based upon the findings of these surveys, we revised the diagnostic criteria. Thyrotoxic storm is still a life-threatening disorder with over 10% mortality in Japan.

  13. Magnetic Storms at Mars and Earth

    DEFF Research Database (Denmark)

    Vennerstrøm, Susanne; Falkenberg, Thea Vilstrup

    In analogy with magnetic storms at the Earth, periods of significantly enhanced global magnetic activity also exist at Mars. The extensive database of magnetic measurements from Mars Global Surveyor (MGS), covering almost an entire solar cycle, is used in combination with geomagnetic activity...... indices at Earth to compare the occurrence of magnetic storms at Mars and Earth. Based on superposed epochs analysis the time-development of typical magnetic storms at Mars and Earth is described. In contradiction to storms at Earth, most magnetic storms at Mars are found to be associated...... with heliospheric current sheet crossings, where the IMF changes polarity. While most storms at the Earth occur due to significant southward excursions of the IMF associated with CMEs, at Mars most storms seem to be associated with the density enhancement of the heliospheric current sheet. Density enhancements...

  14. Thermospheric storms and related ionospheric effects

    International Nuclear Information System (INIS)

    Chandra, S.; Spencer, N.W.

    1976-01-01

    A comparative study of thermospheric storms for the equinox and winter conditions is presented based on the neutral composition measurements from the Aeros-A Nate (Neutral Atmosphere Temperature Experiment) experiment. The main features of the two storms as inferred from the changes in N 2 , Ar, He, and O are described, and their implications to current theories of thermospheric storms are discussed. On the basis of the study of the F region critical frequency measured from a chain of ground-based ionospheric stations during the two storm periods, the general characteristics of the ionospheric storms and the traveling ionospheric disturbances are described. It is suggested that the positive and negative phases of ionospheric storms are the various manifestations of thermospheric storms

  15. Thyroid storm precipitated by duodenal ulcer perforation.

    Science.gov (United States)

    Natsuda, Shoko; Nakashima, Yomi; Horie, Ichiro; Ando, Takao; Kawakami, Atsushi

    2015-01-01

    Thyroid storm is a rare and life-threatening complication of thyrotoxicosis that requires prompt treatment. Thyroid storm is also known to be associated with precipitating events. The simultaneous treatment of thyroid storm and its precipitant, when they are recognized, in a patient is recommended; otherwise such disorders, including thyroid storm, can exacerbate each other. Here we report the case of a thyroid storm patient (a 55-year-old Japanese male) complicated with a perforated duodenal ulcer. The patient was successfully treated with intensive treatment for thyroid storm and a prompt operation. Although it is believed that peptic ulcer rarely coexists with hyperthyroidism, among patients with thyroid storm, perforation of a peptic ulcer has been reported as one of the causes of fatal outcome. We determined that surgical intervention was required in this patient, reported despite ongoing severe thyrotoxicosis, and reported herein a successful outcome.

  16. Thyroid Storm Precipitated by Duodenal Ulcer Perforation

    Directory of Open Access Journals (Sweden)

    Shoko Natsuda

    2015-01-01

    Full Text Available Thyroid storm is a rare and life-threatening complication of thyrotoxicosis that requires prompt treatment. Thyroid storm is also known to be associated with precipitating events. The simultaneous treatment of thyroid storm and its precipitant, when they are recognized, in a patient is recommended; otherwise such disorders, including thyroid storm, can exacerbate each other. Here we report the case of a thyroid storm patient (a 55-year-old Japanese male complicated with a perforated duodenal ulcer. The patient was successfully treated with intensive treatment for thyroid storm and a prompt operation. Although it is believed that peptic ulcer rarely coexists with hyperthyroidism, among patients with thyroid storm, perforation of a peptic ulcer has been reported as one of the causes of fatal outcome. We determined that surgical intervention was required in this patient, reported despite ongoing severe thyrotoxicosis, and reported herein a successful outcome.

  17. Studies of 212Pb storm

    International Nuclear Information System (INIS)

    Yunoki, E.; Kataoka, T.; Michihiro, K.; Sugiyama, H.; Shimizu, M.; Mori, T.

    1996-01-01

    212 Pb which reached its equilibrium state with its daughters in the air was measured around small uranium mines in Japan. Environmental. 212 Pb concentrations rose suddenly and reached a value ten times as high as usual values. These Phenomena were observed many times during the past six Years. We called these Phenomena 212 Pb storms. Meteorological conditions lead to the variations of 220 Rn progeny concentrations. These phenomena have been studied in the point of meteorology. (author)

  18. Using EPA Tools and Data Services to Inform Changes to Design Storm Definitions for Wastewater Utilities based on Climate Model Projections

    Science.gov (United States)

    Tryby, M.; Fries, J. S.; Baranowski, C.

    2014-12-01

    Extreme precipitation events can cause significant impacts to drinking water and wastewater utilities, including facility damage, water quality impacts, service interruptions and potential risks to human health and the environment due to localized flooding and combined sewer overflows (CSOs). These impacts will become more pronounced with the projected increases in frequency and intensity of extreme precipitation events due to climate change. To model the impacts of extreme precipitation events, wastewater utilities often develop Intensity, Duration, and Frequency (IDF) rainfall curves and "design storms" for use in the U.S. Environmental Protection Agency's (EPA) Storm Water Management Model (SWMM). Wastewater utilities use SWMM for planning, analysis, and facility design related to stormwater runoff, combined and sanitary sewers, and other drainage systems in urban and non-urban areas. SWMM tracks (1) the quantity and quality of runoff made within each sub-catchment; and (2) the flow rate, flow depth, and quality of water in each pipe and channel during a simulation period made up of multiple time steps. In its current format, EPA SWMM does not consider climate change projection data. Climate change may affect the relationship between intensity, duration, and frequency described by past rainfall events. Therefore, EPA is integrating climate projection data available in the Climate Resilience Evaluation and Awareness Tool (CREAT) into SWMM. CREAT is a climate risk assessment tool for utilities that provides downscaled climate change projection data for changes in the amount of rainfall in a 24-hour period for various extreme precipitation events (e.g., from 5-year to 100-year storm events). Incorporating climate change projections into SWMM will provide wastewater utilities with more comprehensive data they can use in planning for future storm events, thereby reducing the impacts to the utility and customers served from flooding and stormwater issues.

  19. nuSTORM Costing document

    Energy Technology Data Exchange (ETDEWEB)

    Bross, Alan D. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2013-10-01

    Detailed costing of the nuSTORM conventional facilities has been done by the Fermilab Facilities Engineering Services Section (FESS) and is reported on in the nuSTORM Project Definition Report (PDR) 6-13-1. Estimates for outfitting the primary proton beam line, the target station, the pion capture/transport line and decay ring are based on either experience from existing Fermilab infrastructure (NuMI) or is based on the detailed costing exercises for DOE CD-1 approval for future experiments (mu2e and LBNE). The detector costing utilized the Euronu costing for the Neutrino Factory Magnetized Iron Neutrino Detector (MIND), extrapolations from MINOS as-built costs and from recent vendor quotes. Costs included all manpower and are fully burdened (FY2013 dollars). The costs are not escalated, however, beyond the 5-year project timeline, since a project start for nuSTORM is unknown. Escalation can be estimated from various models (see Figure 1). LBNE has used the Jacob’s model to determine their cost escalation.

  20. Association between Gastrointestinal Illness and Precipitation in Areas Impacted by Combined Sewer Facilities: Analysis of Massachusetts Data, 2003-2007

    Science.gov (United States)

    Background: Combined sewer systems (CSS) collect rainwater runoff, sewage, and industrial wastewater for transit to treatment facilities. With heavy precipitation, volumes can exceed capacity of treatment facilities, and wastewater discharges directly to receiving waters. These c...

  1. A generic methodology for the optimisation of sewer systems using stochastic programming and self-optimizing control.

    Science.gov (United States)

    Mauricio-Iglesias, Miguel; Montero-Castro, Ignacio; Mollerup, Ane L; Sin, Gürkan

    2015-05-15

    The design of sewer system control is a complex task given the large size of the sewer networks, the transient dynamics of the water flow and the stochastic nature of rainfall. This contribution presents a generic methodology for the design of a self-optimising controller in sewer systems. Such controller is aimed at keeping the system close to the optimal performance, thanks to an optimal selection of controlled variables. The definition of an optimal performance was carried out by a two-stage optimisation (stochastic and deterministic) to take into account both the overflow during the current rain event as well as the expected overflow given the probability of a future rain event. The methodology is successfully applied to design an optimising control strategy for a subcatchment area in Copenhagen. The results are promising and expected to contribute to the advance of the operation and control problem of sewer systems. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Suitable flow pattern increases the removal efficiency of nitrogen in gravity sewers: a suitable anoxic and aerobic environment in biofilms.

    Science.gov (United States)

    He, Qiang; Yin, Feixian; Li, Hong; Wang, Yinliang; Xu, Jingwei; Ai, Hainan

    2018-03-25

    The sewers have the function of carbon removal, which has been proven. But if the effect of nitrogen removal can be enhanced at the same time of carbon removal, it can lay a foundation for the realization of "sewer's working as a reactor." This paper investigated the effects of shear stress and C/N ratio on nitrogen removal through biofilms on the sewer inner wall and nitrogen transfer. The main conclusions are as follows: (1) nitrogen could be partially removed in sewers after a series of reactions; (2) the anaerobic, anoxic, aerobic environment and some bacteria related to nitrogen metabolism, which exist in the biofilm, promote the nitrification and denitrification; (3) a total of 722 functional genes involved in nitrogen metabolism were detected in the biofilm (C/N ratio of 10, shear stress of 1.4 Pa), accounting for 0.67% of all genes, and the functional genes related to denitrification were dominant. Graphical abstract ᅟ.

  3. Identification of controlling factors for the initiation of corrosion of fresh concrete sewers.

    Science.gov (United States)

    Jiang, Guangming; Sun, Xiaoyan; Keller, Jurg; Bond, Philip L

    2015-09-01

    The development of concrete corrosion in new sewer pipes undergoes an initiation process before reaching an active corrosion stage. This initiation period is assumed to last several months to years but the key factors affecting the process, and its duration, are not well understood. This study is therefore focused on this initial stage of the corrosion process and the effect of key environmental factors. Such knowledge is important for the effective management of corrosion in new sewers, as every year of life extension of such systems has a very high financial benefit. This long-term (4.5 year) study has been conducted in purpose-built corrosion chambers that closely simulated the sewer environment, but with control of three key environmental factors being hydrogen sulfide (H2S) gas phase concentration, relative humidity and air temperature. Fresh concrete coupons, cut from an industry-standard sewer pipe, were exposed to the corrosive conditions in the chambers, both in the gas phase and partially submerged in wastewater. A total of 36 exposure conditions were investigated to determine the controlling factors by regular retrieval of concrete coupons for detailed analysis of surface pH, sulfur compounds (elemental sulfur and sulfate) and concrete mass loss. Corrosion initiation times were thus determined for different exposure conditions. It was found that the corrosion initiation time of both gas-phase and partially-submerged coupons was positively correlated with the gas phase H2S concentration, but only at levels of 10 ppm or below, indicating that sulfide oxidation rate rather than the H2S concentration was the limiting factor during the initiation stage. Relative humidity also played a role for the corrosion initiation of the gas-phase coupons. However, the partially-submerged coupons were not affected by humidity as these coupons were in direct contact with the sewage and hence did have sufficient moisture to enable the microbial processes to proceed. The

  4. Feasibility of sulfide control in sewers by reuse of iron rich drinking water treatment sludge.

    Science.gov (United States)

    Sun, Jing; Pikaar, Ilje; Sharma, Keshab Raj; Keller, Jürg; Yuan, Zhiguo

    2015-03-15

    Dosage of iron salt is the most commonly used method for sulfide control in sewer networks but incurs high chemical costs. In this study, we experimentally investigate the feasibility of using iron rich drinking water treatment sludge for sulfide control in sewers. A lab-scale rising main sewer biofilm reactor was used. The sulfide concentration in the effluent decreased from 15.5 to 19.8 mgS/L (without dosing) to below 0.7-2.3 mgS/L at a sludge dosing rate achieving an iron to total dissolved inorganic sulfur molar ratio (Fe:S) of 1:1, with further removal of sulfide possible by prolonging the reaction time. In fact, batch tests revealed an Fe consumption to sulfide removal ratio of 0.5 ± 0.02 (mole:mole), suggesting the possible occurrence of other reactions involving the removal of sulfide. Modelling revealed that the reaction between iron in sludge and sulfide has reaction orders of 0.65 ± 0.01 and 0.77 ± 0.02 with respect to the Fe and sulfide concentrations, respectively. The addition of sludge slightly increased the total chemical oxidation demand (tCOD) concentration (by approximately 12%) as expected, but decreased the soluble chemical oxidation demand (sCOD) concentration and methane formation by 7% and 20%, respectively. Some phosphate removal (13%) was also observed at the sludge dosing rate of 1:1 (Fe:S), which is beneficial to nutrient removal from the wastewater. Overall, this study suggests that dosing iron-rich drinking water sludge to sewers could be an effective strategy for sulfide removal in sewer systems, which would also reduce the sludge disposal costs for drinking water treatment works. However, its potential side-effects on sewer sedimentation and on the wastewater treatment plant effluent remain to be investigated. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Impacts and managerial implications for sewer systems due to recent changes to inputs in domestic wastewater - A review.

    Science.gov (United States)

    Mattsson, Jonathan; Hedström, Annelie; Ashley, Richard M; Viklander, Maria

    2015-09-15

    Ever since the advent of major sewer construction in the 1850s, the issue of increased solids deposition in sewers due to changes in domestic wastewater inputs has been frequently debated. Three recent changes considered here are the introduction of kitchen sink food waste disposers (FWDs); rising levels of inputs of fat, oil and grease (FOG); and the installation of low-flush toilets (LFTs). In this review these changes have been examined with regard to potential solids depositional impacts on sewer systems and the managerial implications. The review indicates that each of the changes has the potential to cause an increase in solids deposition in sewers and this is likely to be more pronounced for the upstream reaches of networks that serve fewer households than the downstream parts and for specific sewer features such as sags. The review has highlighted the importance of educational campaigns directed to the public to mitigate deposition as many of the observed problems have been linked to domestic behaviour in regard to FOGs, FWDs and toilet flushing. A standardized monitoring procedure of repeat sewer blockage locations can also be a means to identify depositional hot-spots. Interactions between the various changes in inputs in the studies reviewed here indicated an increased potential for blockage formation, but this would need to be further substantiated. As the precise nature of these changes in inputs have been found to be variable, depending on lifestyles and type of installation, the additional problems that may arise pose particular challenges to sewer operators and managers because of the difficulty in generalizing the nature of the changes, particularly where retrofitting projects in households are being considered. The three types of changes to inputs reviewed here highlight the need to consider whether or not more or less solid waste from households should be diverted into sewers. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Quantification of groundwater infiltration and surface water inflows in urban sewer networks based on a multiple model approach.

    Science.gov (United States)

    Karpf, Christian; Krebs, Peter

    2011-05-01

    The management of sewer systems requires information about discharge and variability of typical wastewater sources in urban catchments. Especially the infiltration of groundwater and the inflow of surface water (I/I) are important for making decisions about the rehabilitation and operation of sewer networks. This paper presents a methodology to identify I/I and estimate its quantity. For each flow fraction in sewer networks, an individual model approach is formulated whose parameters are optimised by the method of least squares. This method was applied to estimate the contributions to the wastewater flow in the sewer system of the City of Dresden (Germany), where data availability is good. Absolute flows of I/I and their temporal variations are estimated. Further information on the characteristics of infiltration is gained by clustering and grouping sewer pipes according to the attributes construction year and groundwater influence and relating these resulting classes to infiltration behaviour. Further, it is shown that condition classes based on CCTV-data can be used to estimate the infiltration potential of sewer pipes. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Degradability of creatinine under sewer conditions affects its potential to be used as biomarker in sewage epidemiology.

    Science.gov (United States)

    Thai, Phong K; O'Brien, Jake; Jiang, Guangming; Gernjak, Wolfgang; Yuan, Zhiguo; Eaglesham, Geoff; Mueller, Jochen F

    2014-05-15

    Creatinine was proposed to be used as a population normalising factor in sewage epidemiology but its stability in the sewer system has not been assessed. This study thus aimed to evaluate the fate of creatinine under different sewer conditions using laboratory sewer reactors. The results showed that while creatinine was stable in wastewater only, it degraded quickly in reactors with the presence of sewer biofilms. The degradation followed first order kinetics with significantly higher rate in rising main condition than in gravity sewer condition. Additionally, daily loads of creatinine were determined in wastewater samples collected on Census day from 10 wastewater treatment plants around Australia. The measured loads of creatinine from those samples were much lower than expected and did not correlate with the populations across the sampled treatment plants. The results suggested that creatinine may not be a suitable biomarker for population normalisation purpose in sewage epidemiology, especially in sewer catchment with high percentage of rising mains. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Sewer Networks Optimization by Particle Swarm Optimization with Abilities of Fly-Back Mechanism and Harmony Memory

    Directory of Open Access Journals (Sweden)

    محسن نفیسی

    2014-10-01

    Full Text Available Lack of an efficient sewer network in urban areas threatens public health and may give rise to contagious diseases. Various optimization methods have been developed for use in designing sewers networks in response to a number of requirements such as the high costs of constructing sewer networks, financial limitations, the presence of both discrete and continuous decision variables, and the nonlinear time complexity of such design problems. In this study, the particle swarm optimization algorithm (PSO with the capability of “fly-back” mechanism equipped with the harmony search (HPSO is used for the optimization of sewers network designs. The objective function consists of minimizing the excavation and embedding costs of commercial pipes. The fly-back mechanism and the harmony memory method are used to prevent leaving out variables from the feasible space of the problem in an attempt to enhance model efficiency. Model constraints are satisfied at two levels, which leads to the desirable convergence of the PSO algorithm as compared to the conventional penalty methods in alternative evolutionary algorithms. In order to determine the admissible decision variables, the Manning equation is used as a hydraulic model. The performance of the proposed algorithm is shown by presenting two examples of sewer networks. Compared to the PSO algorithm used in sewer network optimization models, the proposed model exhibits a tangible improvement in cost reduction and a higher computational stability.

  9. Investigations to identify organic pollutions in sewer slime. Final report; Untersuchungen zur Identifizierung organischer Schadstoffe in Sielhaeuten. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Antusch, E.; Sauer, J.; Ripp, C.; Hahn, H.H.

    1997-07-31

    An analytical method to measure organic compounds in sewer slime and sewage sludge has been developed. The method needs no halogenated solvents. Furthermore, the sorption behavior of sewer slime has been investigated. Chlorophenols, as an example of more polar organic compounds, show a more stronger and faster desorption from sewer slime than for example PAH. pH-value and fat-content (resp. content of organic carbon) are the most important parameters affecting the sorption kinetic and sorption capacity of sewer slime. To get comparable results, all datas should be refered to the content of organic carbon of the sewer slime. By constructing pollutions-profiles of parameters like AOX, PCB, Flame Protection Agencies and PAH in the sewers of an industrial area, emissions could be localized. (orig.) [Deutsch] Es wurde eine analytische Methode entwickelt, die es erlaubt, ein breites Spektrum lipophiler organischer Schadstoffe in Sielhaut und Klaerschlamm zu identifizieren, als quantitativ zu bestimmen. Die Methode kommt ohne halogenierte Loesungsmittel aus. Verbindungen, die aufgrund ihrer Wasserunloeslichkeit nicht im Abwasser nachgewiesen werden konnten, koennen durch Sielhautanalyse verfolgt werden. Anhand von Schadstoffprofilen in Nebensammlern eines Industriegebietes konnte beispielhaft die Lokalisierung von punktfoermigen Schadstoffeinleitungen demonstriert werden. Erfolgreich verlief auch die Identifizierung eines AOX-Emittenten. Ebenso sind die Eintragspfade von Stoffen, die im Verdacht stehen, endokrine Wirkungen zu haben mit Sielhautanalyse aufklaerbar. Das Sorptionsverhalten der Sielhaut wird durch Faktoren, wie pH und Fettgehalt gepraegt. Bei der Auswertung der Proben muessen die Werte auf den organischen Kohlenstoffgehalt bezogen werden. (orig.)

  10. Estimation of combined sewer overflow discharge: a software sensor approach based on local water level measurements.

    Science.gov (United States)

    Ahm, Malte; Thorndahl, Søren; Nielsen, Jesper E; Rasmussen, Michael R

    2016-12-01

    Combined sewer overflow (CSO) structures are constructed to effectively discharge excess water during heavy rainfall, to protect the urban drainage system from hydraulic overload. Consequently, most CSO structures are not constructed according to basic hydraulic principles for ideal measurement weirs. It can, therefore, be a challenge to quantify the discharges from CSOs. Quantification of CSO discharges are important in relation to the increased environmental awareness of the receiving water bodies. Furthermore, CSO discharge quantification is essential for closing the rainfall-runoff mass-balance in combined sewer catchments. A closed mass-balance is an advantage for calibration of all urban drainage models based on mass-balance principles. This study presents three different software sensor concepts based on local water level sensors, which can be used to estimate CSO discharge volumes from hydraulic complex CSO structures. The three concepts were tested and verified under real practical conditions. All three concepts were accurate when compared to electromagnetic flow measurements.

  11. Stable isotopes of water as a natural tracer for infiltration into urban sewer systems

    Science.gov (United States)

    Kracht, O.; Gresch, M.; de Bénédittis, J.; Prigiobbe, V.; Gujer, W.

    2003-04-01

    An adequate understanding of the hydraulic interaction between leaky sewers and groundwater is essential for the sustainable management of both sewer systems and aquifers in urbanized areas. Undesirable infiltration of groundwater into sewers can contribute over 50% of the total discharge and is detrimental to treatment plant efficiency. On the other hand, in many European cities groundwater surface levels seem to be particularly controlled by the drainage effect of permeable sewer systems. However, nowadays methods for the quantification of these exchange processes are still subject to considerable uncertainties due to their underlying assumptions. The frequently used assumption that the night time minimum in the diurnal wastewater hydrograph is equal to the "parasitic discharge" has to be reconsidered to today's patterns of human life as well as to the long residence time of wastewater in the sewer networks of modern cities. The suitability of stable water isotopes as a natural tracer to differentiate the origin of water in the sewer ("real" wastewater or infiltrating groundwater) is currently investigated in three different catchment areas. The studies are carried out within the framework of the European research project APUSS (Assessing Infiltration and Exfiltration on the Performance of Urban Sewer Systems): 1) The village of Rümlang (Zürich, Switzerland) is predominantly served with drinking water from the Lake Zürich. A large fraction of the lakes water is derived from precipitation in the Alps. This drinking water represents the intrinsic provenience of the wastewater with an δ18O value around -11,5 per mill and δ^2H value around -82 per mill vs. SMOW. In contrast, the local groundwater is originating from precipitation in a moderate altitude of about 450 m above sea level and shows comparatively enriched mean δ18O values of -9,7 per mill and δ^2H values of -70 per mill with only small natural variations. The isotopic separation between these

  12. EMISSION OF POLLUTANTS FROM COMBINED SEWER OVERFLOWS IN THE ASPECT OF THEIR IMPACT ON A RECEIVER

    Directory of Open Access Journals (Sweden)

    Agnieszka Brzezińska

    2016-06-01

    Full Text Available Increased efficiency of wastewater treatment highlights the role of combined sewer overflows in deterioration the quality of water receiver because pollutant loads discharged by them have a growing share in entire load discharged into a receiver. The article contains the results of the wastewater quality analyzes emitted into the receiver from the three studied combined sewer overflows of the city of Lodz. The results demonstrated a large variations in the pollutant concentration directed to the receiver during rain events. The possible impact of untreated wastewater emitted to the receiver is also presented. Apart from the pollution of the receiver, mainly by organic and nutrient substances, the microbiological contamination which is dangerous for people using the river as a recreation area and for animals that use a water receiver as a source of drinking water, should be taken into particular attention.

  13. Cesium and strontium loads into a combined sewer system from rainwater runoff.

    Science.gov (United States)

    Kamei-Ishikawa, Nao; Yoshida, Daiki; Ito, Ayumi; Umita, Teruyuki

    2016-12-01

    In this study, combined sewage samples were taken with time in several rain events and sanitary sewage samples were taken with time in dry weather to calculate Cs and Sr loads to sewers from rainwater runoff. Cs and Sr in rainwater were present as particulate forms at first flush and the particulate Cs and Sr were mainly bound with inorganic suspended solids such as clay minerals in combined sewage samples. In addition, multiple linear regression analysis showed Cs and Sr loads from rainwater runoff could be estimated by the total amount of rainfall and antecedent dry weather days. The variation of the Sr load from rainwater to sewers was more sensitive to total amount of rainfall and antecedent dry weather days than that of the Cs load. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. The electric storm of November 1882

    Science.gov (United States)

    Love, Jeffrey J.

    2018-01-01

    In November 1882, an intense magnetic storm related to a large sunspot group caused widespread interference to telegraph and telephone systems and provided spectacular and unusual auroral displays. The (ring current) storm time disturbance index for this storm reached maximum −Dst ≈ 386 nT, comparable to Halloween storm of 29–31 October 2003, but from 17 to 20 November the aa midlatitude geomagnetic disturbance index averaged 214.25 nT, the highest 4 day level of disturbance since the beginning of aa index in 1868. This storm contributed to scientists' understanding of the reality of solar‐terrestrial interaction. Past occurrences of magnetic storms, like that of November 1882, can inform modern evaluations of the deleterious effects that a magnetic superstorm might have on technological systems of importance to society.

  15. Extreme Geomagnetic Storms – 1868–2010

    DEFF Research Database (Denmark)

    Vennerstrøm, Susanne; Lefèvre, L.; Dumbović, M.

    2016-01-01

    presents our investigation of the corresponding solar eventsand their characteristics. The storms were selected based on their intensity in the aa index,which constitutes the longest existing continuous series of geomagnetic activity. They areanalyzed statistically in the context of more well...... occurring in May 1921 and the Quebec storm from March 1989. We identifykey characteristics of the storms by combining several different available data sources, listsof storm sudden commencements (SSCs) signifying occurrence of interplanetary shocks,solar wind in-situ measurements, neutron monitor data...... %), Forbushdecreases (100 %), and energetic solar proton events (70 %). A quantitative comparison ofthese associations relative to less intense storms is also presented. Most notably, we findthat most often the extreme storms are characterized by a complexity that is associated with multiple, often interacting, solar...

  16. Bacterial diversity impacts as a result of combined sewer overflow in a polluted waterway

    Directory of Open Access Journals (Sweden)

    O. Calderon

    2017-12-01

    Full Text Available Newtown Creek is an industrial waterway and former tidal wetland in New York City. It is one of the most polluted water bodies in the United States and was designated as a superfund site in 2010. For over a century, organic compounds, heavy metals, and other forms of industrial pollution have disrupted the creek’s environment. The creek is also impacted by discharges from twenty combined sewer overflow pipes, which may deposit raw sewage or partially treated wastewater directly into the creek during heavy or sustained rain events. Combined sewer overflow events and associated nutrient over-enrichment at the creek drive eutrophication and subsequent hypoxia. At the current study, three sites were sampled one week apart during a dry period and a wet period, where indication of a combined sewage overflow event could be detected. 16s rRNA high-throughput sequencing from these three sites collectively yielded over 1000 species of bacteria belonging to twenty-two classes. Based on these data, it is hypothesized that differences identified in the microbiome on wet versus dry days are as a result of combined sewage overflow, street runoff, and additional fluctuations in the creek’s environment associated with rain. It was found that after a combined sewer overflows event, the levels of Gamma Proteobacteria increased while the levels of Actinobacteria decreased. However, levels of bacteria stayed relatively unchanged at a site further away from combined sewer overflows discharge. Species found in Newtown Creek include pelagic, marine, human and animal pathogens, hydrocarbonoclastic, and other environmental microbes.

  17. Sewer-mining: A water reuse option supporting circular economy, public service provision and entrepreneurship.

    Science.gov (United States)

    Makropoulos, C; Rozos, E; Tsoukalas, I; Plevri, A; Karakatsanis, G; Karagiannidis, L; Makri, E; Lioumis, C; Noutsopoulos, C; Mamais, D; Rippis, C; Lytras, E

    2018-06-15

    Water scarcity, either due to increased urbanisation or climatic variability, has motivated societies to reduce pressure on water resources mainly by reducing water demand. However, this practice alone is not sufficient to guarantee the quality of life that high quality water services underpin, especially within a context of increased urbanisation. As such, the idea of water reuse has been gaining momentum for some time and has recently found a more general context within the idea of the Circular Economy. This paper is set within the context of an ongoing discussion between centralized and decentralized water reuse techniques and the investigation of trade-offs between efficiency and economic viability of reuse at different scales. Specifically, we argue for an intermediate scale of a water reuse option termed 'sewer-mining', which could be considered a reuse scheme at the neighbourhood scale. We suggest that sewer mining (a) provides a feasible alternative reuse option when the geography of the wastewater treatment plant is problematic, (b) relies on mature treatment technologies and (c) presents an opportunity for Small Medium Enterprises (SME) to be involved in the water market, securing environmental, social and economic benefits. To support this argument, we report on a pilot sewer-mining application in Athens, Greece. The pilot, integrates two subsystems: a packaged treatment unit and an information and communications technology (ICT) infrastructure. The paper reports on the pilot's overall performance and critically evaluates the potential of the sewer-mining idea to become a significant piece of the circular economy puzzle for water. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Down Under – Aspects of Microbial Fuel Cell’s sewer implementation

    OpenAIRE

    Andrich, Jonas Maximilian Sven

    2017-01-01

    Increasing energy demand and simultaneous depletion of raw materials requires us to use existing resources more wisely. Microbial Fuel Cells (MFCs) recover energy from waste water while clearing it. The sewage system with its million-kilometer-length is a highly interesting field for its application. The present work is therefore dedicated to aspects of Microbial Fuel Cells’ sewer implementation. Firstly, the wastewater infrastructure was evaluated with respect to suitable implementation s...

  19. Tracking artificial sweeteners and pharmaceuticals introduced into urban groundwater by leaking sewer networks.

    Science.gov (United States)

    Wolf, Leif; Zwiener, Christian; Zemann, Moritz

    2012-07-15

    There is little quantitative information on the temporal trends of pharmaceuticals and other emerging compounds, including artificial sweeteners, in urban groundwater and their suitability as tracers to inform urban water management. In this study, pharmaceuticals and artificial sweeteners were monitored over 6 years in a shallow urban groundwater body along with a range of conventional sewage tracers in a network of observation wells that were specifically constructed to assess sewer leakage. Out of the 71 substances screened, 24 were detected at above the analytical detection limit. The most frequent compounds were the iodinated X-ray contrast medium amidotrizoic acid (35.3%), the anticonvulsant carbamazepine (33.3%) and the artificial sweetener acesulfame (27.5%), while all other substances occurred in less than 10% of the screened wells. The results from the group of specifically constructed focus wells within 10 m of defective sewers confirmed sewer leaks as being a major entrance pathway into the groundwater. The spatial distribution of pharmaceuticals and artificial sweeteners corresponds well with predictions by pipeline leakage models, which operate on optical sewer condition monitoring data and hydraulic information. Correlations between the concentrations of carbamazepine, iodinated X-ray contrast media and artificial sweeteners were weak to non-existent. Peak concentrations of up to 4130 ng/l of amidotrizoic acid were found in the groundwater downstream of the local hospital. The analysis of 168 samples for amidotrizoic acid, taken at 5 different occasions, did not show significant temporal trends for the years 2002-2008, despite changed recommendations in the medical usage of amidotrizoic acid. The detailed results show that the current mass balance approaches for urban groundwater bodies must be adapted to reflect the spatially distributed leaks and the variable wastewater composition in addition to the lateral and horizontal groundwater fluxes. Crown

  20. Population ecology and movement of the American cockroach (Dictyoptera: Blattidae) in sewers.

    Science.gov (United States)

    Tee, Hui-Siang; Saad, Ahmad Ramli; Lee, Chow-Yang

    2011-07-01

    The population size, age-class structure, and movement of the American cockroach, Periplaneta americana (L.) (Dictyoptera: Blattidae), were studied in three sewers in Penang, Malaysia, from September 2008 to October 2009. Eighteen to 20 glass-jar traps (two per manhole) were deployed for a 24-h period during each sampling occasion at each sewer. Adults and nymphs were active throughout the study period, with an average monthly trap catch of 57-97 adults and 79-99 nymphs. The mean proportions of adults and nymphs at the three sewers ranged from 0.47 to 0.57. Of the 2177 male and 2717 female cockroaches marked and released over the three sewers, recapture rates were 29.4-45.8 and 30.8-47.0%, respectively. The proportion of marked males and females did not differ significantly from the proportion of recaptured marked males and females. However, the mean number of times a marked female was recaptured was significantly greater than that of males. Of the 783 males and 1,030 females that were marked and recaptured, 19.4 and 24.7%, respectively, had moved between manholes, and significantly more females than males moved between manholes. Of the 406 recaptured marked adults that moved between manholes, 90.4% moved a distance of 2-20 m from their initial release site; one male moved 192 m, the longest distance recorded. Trap catch on each sampling occasion was positively correlated with daily mean temperature. The number of cockroach movements between manholes also was correlated with the mean daily minimum temperature.

  1. Improved Storm Monitoring and Prediction for the San Francisco Bay Area

    Science.gov (United States)

    Cifelli, R.; Chandrasekar, V.; Anderson, M.; Davis, G.

    2017-12-01

    The Advanced Quantitative Precipitation Information (AQPI) System is a multi-faceted project to improve precipitation and hydrologic monitoring, prediction, and decision support for the San Francisco Bay Area. The Bay Area faces a multitude of threats from extreme events, including disrupted transportation from flooded roads and railroad lines, water management challenges related to storm water, river and reservoir management and storm-related damage demanding emergency response. The threats occur on spatial scales ranging from local communities to the entire region and time scales ranging from hours to days. These challenges will be exacerbated by future sea level rise, more extreme weather events and increased vulnerabilities. AQPI is a collaboration of federal, state and local governments with assistance from the research community. Led by NOAA's Earth System Research Laboratory, in partnership with the Cooperative Institute for Research in the Atmosphere, USGS, and Scripps, AQPI is a four-year effort funded in part by a grant from the California Department of Water Resource's Integrated Regional Water Management Program. The Sonoma County Water Agency is serving as the local sponsor of the project. Other local participants include the Santa Clara Valley Water District, San Francisco Public Utilities Commission, and the Bay Area Flood Protection Agencies Association. AQPI will provide both improved observing capabilities and a suite of numerical forecast models to produce accurate and timely information for benefit of flood management, emergency response, water quality, ecosystem services, water supply and transportation management for the Bay Area. The resulting information will support decision making to mitigate flood risks, secure water supplies, minimize water quality impacts to the Bay from combined sewer overflows, and have improved lead-time on coastal and Bay inundation from extreme storms like Atmospheric Rivers (ARs). The project is expected to

  2. Water quantity and quality response of a green roof to storm events: Experimental and monitoring observations.

    Science.gov (United States)

    Carpenter, Corey M G; Todorov, Dimitar; Driscoll, Charles T; Montesdeoca, Mario

    2016-11-01

    Syracuse, New York is working under a court-ordered agreement to limit combined sewer overflows (CSO) to local surface waters. Green infrastructure technologies, including green roofs, are being implemented as part of a CSO abatement strategy and to develop co-benefits of diminished stormwater runoff, including decreased loading of contaminants to the wastewater system and surface waters. The objective of this study was to examine the quantity and quality of discharge associated with precipitation events over an annual cycle from a green roof in Syracuse, NY and to compare measurements from this monitoring program with results from a roof irrigation experiment. Wet deposition, roof drainage, and water quality were measured for 87 storm events during an approximately 12 month period over 2011-2012. Water and nutrient (total phosphorus, total nitrogen, and dissolved organic carbon) mass balances were conducted on an event basis to evaluate retention annually and during the growing and non-growing seasons. These results are compared with a hydrological manipulation experiment, which comprised of artificially watering of the roof. Loadings of nutrients were calculated for experimental and actual storms using the concentration of nutrients and the flow data of water discharging the roof. The green roof was effective in retaining precipitation quantity from storm events (mean percent retention 96.8%, SD = 2.7%, n = 87), although the relative fraction of water retained decreased with increases in the size of the event. There was no difference in water retention of the green roof for the growing and non-growing seasons. Drainage waters exhibited high concentration of nutrients during the warm temperature growing season, particularly total nitrogen and dissolved organic carbon. Overall, nutrient losses were low because of the strong retention of water. However, there was marked variation in the retention of nutrients by season due to variations in concentrations in roof

  3. Alternative salvage technique during postcardiotomy electrical storm.

    Science.gov (United States)

    Ryu, Y G; Baek, M J; Kim, H J

    2010-08-01

    Cardiac electrical storm is generally treated with antiarrhythmic drugs, electrical cardioversion, or catheter ablation. However, these conservative treatment modalities are considered neither curative nor preventive with regard to recurrent arrhythmias in postoperative electrical storm after open heart surgery. We present a case of surgical ventricular assist device placement for postcardiotomy electrical storm in a 38-year-old patient. Copyright (c) Georg Thieme Verlag KG Stuttgart-New York.

  4. New storm water regulations impact industry

    International Nuclear Information System (INIS)

    Gemar, C.

    1991-01-01

    In November 1990, new Environmental Protection Agency (EPA) regulations aimed at governing the discharge of storm water from industrial facilities became effective. Because some industrial runoff contains toxics and other pollutants, the EPA considers storm water a major source of water contamination. The new regulations will have a profound impact on the National Pollutant Discharge Elimination System (NPDES) permit requirements for industry. This paper summarizes the new storm water regulations, focusing on the requirements for industrial facilities. It also presents suggestions for compliance

  5. Coastal Storm Hazards from Virginia to Maine

    Science.gov (United States)

    2015-11-01

    secondary terms • integration of joint probability of storm responses, including extratropical events. A diagram summarizing the JPM methodology is... Extratropical Cyclones. The GPD- based approach defined above was used to compute the final storm response statistics for XCs. ERDC/CHL TR-15-5 39...from the numerical modeling of all storms , tropical and extratropical . As discussed in Section 2.1.2, JPM methodology generally consists of the

  6. DSM-flux: A new technology for reliable Combined Sewer Overflow discharge monitoring with low uncertainties.

    Science.gov (United States)

    Maté Marín, Ainhoa; Rivière, Nicolas; Lipeme Kouyi, Gislain

    2018-06-01

    In the past ten years, governments from the European Union have been encouraged to collect volume and quality data for all the effluent overflows from separated stormwater and combined sewer systems that result in a significant environmental impact on receiving water bodies. Methods to monitor and control these flows require improvements, particularly for complex Combined Sewer Overflow (CSO) structures. The DSM-flux (Device for Stormwater and combined sewer flows Monitoring and the control of pollutant fluxes) is a new pre-designed and pre-calibrated channel that provides appropriate hydraulic conditions suitable for measurement of overflow rates and volumes by means of one water level gauge. In this paper, a stage-discharge relation for the DSM-flux is obtained experimentally and validated for multiple inflow hydraulic configurations. Uncertainties in CSO discharges and volumes are estimated within the Guide to the expression of Uncertainty in Measurement (GUM) framework. Whatever the upstream hydraulic conditions are, relative uncertainties are lower than 15% and 2% for the investigated discharges and volumes, respectively. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. DESIGN AND TECHNOLOGICAL SOLUTIONS FOR THE RESTORATION OF SEWERS USING ELEMENTS OF RECYCLED POLYMER COMPOSITE MATERIALS

    Directory of Open Access Journals (Sweden)

    GONCHARENKO D. F.

    2017-01-01

    Full Text Available Problem statement. Currently sanitary drainage systems of large cities in Ukraine are significantly worn down with prolonged use and due to inefficient solutions for protection of the structures from aggressive effects of the environment, poor quality of materials and construction and installation works during building. Restoration of performance characteristics, reliability and durability of sewer tunnels is the costly and technically complex task, which is urgently needed to be fulfilled to prevent accidents including those with serious environmental impact. Modern work technique and the materials used for restoration allow us to solve these problems with different levels of efficiency, while reducing the cost of restoration due to use of recycled polymeric raw material, as well as to improvement of technological solutions is a currently important direction of research. Purpose of the article. To develop solutions for restoring serviceability, reliability and durability of sewer tunnels taking into account the accumulated experience in renovation of water disposal networks. Conclusion. Use of components made of recycled polymer composite materials during restoring sewer tunnels has significant economic and environmental effects and allows to undertake repair work in hard-to-reach areas.

  8. Evaluation of exposure pathways to man from disposal of radioactive materials into sanitary sewer systems

    Energy Technology Data Exchange (ETDEWEB)

    Kennedy, W.E. Jr.; Parkhurst, M.A.; Aaberg, R.L.; Rhoads, K.C.; Hill, R.L.; Martin, J.B. [Pacific Northwest Lab., Richland, WA (United States)

    1992-05-01

    In accordance with 10 CFR 20, the US Nuclear Regulatory Commission (NRC) regulates licensees` discharges of small quantities of radioactive materials into sanitary sewer systems. This generic study was initiated to examine the potential radiological hazard to the public resulting from exposure to radionuclides in sewage sludge during its treatment and disposal. Eleven scenarios were developed to characterize potential exposures to radioactive materials during sewer system operations and sewage sludge treatment and disposal activities and during the extended time frame following sewage sludge disposal. Two sets of deterministic dose calculations were performed; one to evaluate potential doses based on the radionuclides and quantities associated with documented case histories of sewer system contamination and a second, somewhat more conservative set, based on theoretical discharges at the maximum allowable levels for a more comprehensive list of 63 radionuclides. The results of the stochastic uncertainty and sensitivity analysis were also used to develop a collective dose estimate. The collective doses for the various radionuclides and scenarios range from 0.4 person-rem for {sup 137}Cs in Scenario No. 5 (sludge incinerator effluent) to 420 person-rem for {sup 137}Cs in Scenario No. 3 (sewage treatment plant liquid effluent). None of the 22 scenario/radionuclide combinations considered have collective doses greater than 1000 person-rem/yr. However, the total collective dose from these 22 combinations was found to be about 2100 person-rem.

  9. Constructed Wetlands for Combined Sewer Overflow Treatment—Comparison of German, French and Italian Approaches

    Directory of Open Access Journals (Sweden)

    Daniel Meyer

    2012-12-01

    Full Text Available Combined sewer systems are designed to transport stormwater surface run off in addition to the dry weather flows up to defined limits. In most European countries, hydraulic loads greater than the design flow are discharged directly into receiving water bodies, with minimal treatment (screening, sedimentation, or with no treatment at all. One feasible solution to prevent receiving waters from strong negative impacts seems to be the application of vertical flow constructed wetlands. In Germany, first attempts to use this ecological technology were recognized in early 1990s. Since then, further development continued until a high level of treatment performance was reached. During recent years the national “state-of-the-art” (defined in 2005 was adapted in other European countries, including France and Italy. Against the background of differing national requirements in combined sewer system design, substantial developmental steps were taken. The use of coarser filter media in combination with alternating loadings of separated filter beds allows direct feedings with untreated combined runoff. Permanent water storage in deep layers of the wetland improves the system’s robustness against extended dry periods, but contains operational risks. Besides similar functions (but different designs and layouts, correct dimensioning of all approaches suffers from uncertainties in long-term rainfall predictions as well as inside sewer system simulation tools.

  10. Update summary of the 1991 discharge of enriched uranium to the sanitary sewer (DEUSS) report

    International Nuclear Information System (INIS)

    1995-04-01

    Since the 1991 Y-12 Plant report, a flow study of the Y-12 Plant sanitary sewer collection system has been completed by the Y-12 Plant staff (Hanzelka and Maguire, 1993). Additional data has been obtained by the Y-12 Plant and the City of Oak Ridge (COR, 1994). COR developed limits on radionuclide concentrations in sludges used for land application (Stetar, 1993). Martin Marietta Energy Systems has provided recommendations to the Department of Energy (DOE) regarding the impacts of sludge land farming operations on the ORR (Frye, 1992). The DOE Office of Nuclear Safety (USDOE, 1993) completed an audit of activities related to radiological contamination of the COR sewer system due to DOE operations. In addition COR is currently developing limits on radionuclide releases for all industrial customers to be applied through the permitting process. In 1994, a new sanitary sewer monitoring station was installed and began operation at the Y-12 Plant to determine releases specifically from the Y-12 Plant. Previously, estimates were based on mass balance calculations using data from the City Monitoring Station which monitors Union Valley and Y-12 Plant releases. The purpose of this report is to update the 1991 Y-12 Plant study taking into account current data and information

  11. Evaluation of exposure pathways to man from disposal of radioactive materials into sanitary sewer systems

    International Nuclear Information System (INIS)

    Kennedy, W.E. Jr.; Parkhurst, M.A.; Aaberg, R.L.; Rhoads, K.C.; Hill, R.L.; Martin, J.B.

    1992-05-01

    In accordance with 10 CFR 20, the US Nuclear Regulatory Commission (NRC) regulates licensees' discharges of small quantities of radioactive materials into sanitary sewer systems. This generic study was initiated to examine the potential radiological hazard to the public resulting from exposure to radionuclides in sewage sludge during its treatment and disposal. Eleven scenarios were developed to characterize potential exposures to radioactive materials during sewer system operations and sewage sludge treatment and disposal activities and during the extended time frame following sewage sludge disposal. Two sets of deterministic dose calculations were performed; one to evaluate potential doses based on the radionuclides and quantities associated with documented case histories of sewer system contamination and a second, somewhat more conservative set, based on theoretical discharges at the maximum allowable levels for a more comprehensive list of 63 radionuclides. The results of the stochastic uncertainty and sensitivity analysis were also used to develop a collective dose estimate. The collective doses for the various radionuclides and scenarios range from 0.4 person-rem for 137 Cs in Scenario No. 5 (sludge incinerator effluent) to 420 person-rem for 137 Cs in Scenario No. 3 (sewage treatment plant liquid effluent). None of the 22 scenario/radionuclide combinations considered have collective doses greater than 1000 person-rem/yr. However, the total collective dose from these 22 combinations was found to be about 2100 person-rem

  12. Validation of Storm Water Management Model Storm Control Measures Modules

    Science.gov (United States)

    Simon, M. A.; Platz, M. C.

    2017-12-01

    EPA's Storm Water Management Model (SWMM) is a computational code heavily relied upon by industry for the simulation of wastewater and stormwater infrastructure performance. Many municipalities are relying on SWMM results to design multi-billion-dollar, multi-decade infrastructure upgrades. Since the 1970's, EPA and others have developed five major releases, the most recent ones containing storm control measures modules for green infrastructure. The main objective of this study was to quantify the accuracy with which SWMM v5.1.10 simulates the hydrologic activity of previously monitored low impact developments. Model performance was evaluated with a mathematical comparison of outflow hydrographs and total outflow volumes, using empirical data and a multi-event, multi-objective calibration method. The calibration methodology utilized PEST++ Version 3, a parameter estimation tool, which aided in the selection of unmeasured hydrologic parameters. From the validation study and sensitivity analysis, several model improvements were identified to advance SWMM LID Module performance for permeable pavements, infiltration units and green roofs, and these were performed and reported herein. Overall, it was determined that SWMM can successfully simulate low impact development controls given accurate model confirmation, parameter measurement, and model calibration.

  13. Topographic Correction Module at Storm (TC@Storm)

    Science.gov (United States)

    Zaksek, K.; Cotar, K.; Veljanovski, T.; Pehani, P.; Ostir, K.

    2015-04-01

    Different solar position in combination with terrain slope and aspect result in different illumination of inclined surfaces. Therefore, the retrieved satellite data cannot be accurately transformed to the spectral reflectance, which depends only on the land cover. The topographic correction should remove this effect and enable further automatic processing of higher level products. The topographic correction TC@STORM was developed as a module within the SPACE-SI automatic near-real-time image processing chain STORM. It combines physical approach with the standard Minnaert method. The total irradiance is modelled as a three-component irradiance: direct (dependent on incidence angle, sun zenith angle and slope), diffuse from the sky (dependent mainly on sky-view factor), and diffuse reflected from the terrain (dependent on sky-view factor and albedo). For computation of diffuse irradiation from the sky we assume an anisotropic brightness of the sky. We iteratively estimate a linear combination from 10 different models, to provide the best results. Dependent on the data resolution, we mask shades based on radiometric (image) or geometric properties. The method was tested on RapidEye, Landsat 8, and PROBA-V data. Final results of the correction were evaluated and statistically validated based on various topography settings and land cover classes. Images show great improvements in shaded areas.

  14. Ice storm 1998 : lessons learned

    Energy Technology Data Exchange (ETDEWEB)

    McCready, J. [Eastern Ontario Model Forest, Kemptville, ON (Canada)

    2006-07-01

    This paper presented details of a partnership formed in response to the ice storm of 1998, which caused extensive damage to trees in woodlots and urban settings in eastern Ontario and western Quebec. The aim of the Ice Storm Forest Recovery Group was to assist in the recovery of eastern forests, collect information on the extent of the damage to trees as well as contribute to the development of assistance programs for woodlot owners and municipalities. In response to the group's request, an initial aerial survey was conducted by the Ontario Ministry of Natural Resources to map the extent of the damage in eastern Ontario, which was followed by a more scientific survey with the Canadian Forest Service through the development of a flying grid pattern to observe the status of trees, followed by extensive ground checks. Damage was variable, depending on tree species, stand age and composition, management practices, wind direction, topography and ice deposition patterns. A summary of the severity of damage indicated that conifers suffered less than hardwoods. Consultants were hired to prepare news releases and extension notes to the public in order to provide information for the caring of trees. Various educational workshops were held which attracted large numbers of landowners and homeowners. A literature review was undertaken to produce a summary of current published knowledge covering the effects of storms and ice damage to trees and forests. Science efforts were published in a series of papers, and financial assistance programs were then organized by governmental agencies. It was concluded that cooperation between all agencies, groups and levels of government is needed in order to coordinate effective emergency strategies. 7 refs., 1 tab., 1 fig.

  15. The structure of the big magnetic storms

    International Nuclear Information System (INIS)

    Mihajlivich, J. Spomenko; Chop, Rudi; Palangio, Paolo

    2010-01-01

    The records of geomagnetic activity during Solar Cycles 22 and 23 (which occurred from 1986 to 2006) indicate several extremely intensive A-class geomagnetic storms. These were storms classified in the category of the Big Magnetic Storms. In a year of maximum solar activity during Solar Cycle 23, or more precisely, during a phase designated as a post-maximum phase in solar activity (PPM - Phase Post maximum), near the autumn equinox, on 29, October 2003, an extremely strong and intensive magnetic storm was recorded. In the first half of November 2004 (7, November 2004) an intensive magnetic storm was recorded (the Class Big Magnetic Storm). The level of geomagnetic field variations which were recorded for the selected Big Magnetic Storms, was ΔD st=350 nT. For the Big Magnetic Storms the indicated three-hour interval indices geomagnetic activity was Kp = 9. This study presents the spectral composition of the Di - variations which were recorded during magnetic storms in October 2003 and November 2004. (Author)

  16. [Thyrotoxic storm and myxedema coma].

    Science.gov (United States)

    Takasu, N

    1999-08-01

    Thyrotoxic or hyperthyroid storm is a grave, life-threatening, but relatively infrequent medical emergency. Immediate causes of death in this emergency are severe hyperpyrexia and pulmonary edema associated with arrhythmias, shock, and coma. This emergency is found in Graves' patients most frequently. Myxedema coma is an emergency clinical state caused by severe deficiency of thyroid hormones. This crisis represents the extreme expression of hypothyroidism. While it is quite useful to elicit a history of previous hypothyroidism, thyroid surgery, or radioactive iodine treatment, it is not obtainable.

  17. Proxy records of Holocene storm events in coastal barrier systems: Storm-wave induced markers

    Science.gov (United States)

    Goslin, Jérôme; Clemmensen, Lars B.

    2017-10-01

    Extreme storm events in the coastal zone are one of the main forcing agents of short-term coastal system behavior. As such, storms represent a major threat to human activities concentrated along the coasts worldwide. In order to better understand the frequency of extreme events like storms, climate science must rely on longer-time records than the century-scale records of instrumental weather data. Proxy records of storm-wave or storm-wind induced activity in coastal barrier systems deposits have been widely used worldwide in recent years to document past storm events during the last millennia. This review provides a detailed state-of-the-art compilation of the proxies available from coastal barrier systems to reconstruct Holocene storm chronologies (paleotempestology). The present paper aims (I) to describe the erosional and depositional processes caused by storm-wave action in barrier and back-barrier systems (i.e. beach ridges, storm scarps and washover deposits), (ii) to understand how storm records can be extracted from barrier and back-barrier sedimentary bodies using stratigraphical, sedimentological, micro-paleontological and geochemical proxies and (iii) to show how to obtain chronological control on past storm events recorded in the sedimentary successions. The challenges that paleotempestology studies still face in the reconstruction of representative and reliable storm-chronologies using these various proxies are discussed, and future research prospects are outlined.

  18. In the Eye of the Storm: A Participatory Course on Coastal Storms

    Science.gov (United States)

    Curtis, Scott

    2013-01-01

    Storm disasters are amplified in the coastal environment due to population pressures and the power of the sea. The upper-division/graduate university course "Coastal Storms" was designed to equip future practitioners with the skills necessary to understand, respond to, and mitigate for these natural disasters. To accomplish this, "Coastal Storms"…

  19. Implementation of an integrated real-time control system of sewer system and waste water treatment plant in the city of Wilhelmshaven

    DEFF Research Database (Denmark)

    Seggelke, Katja; Löwe, Roland; Beeneken, Thomas

    2013-01-01

    A case study for integrated real-time control (RTC) of an urban drainage system in the city of Wilhelmshaven (Germany) is explained. The fuzzy based RTC strategy combines control of the sewer system and inflow to the waste water treatment plant. The main objective in controlling the sewer system...... is to reduce the number of overflows and the volume at a combined sewer overflow (CSO), located close to a bathing beach. Based on online measurements, the operation mode of two pumping stations is modified. This approach allows the safe activation of free storage volume in the sewer system without...... RTC system has been operational for approximately one year....

  20. Spring Dust Storm Smothers Beijing

    Science.gov (United States)

    2002-01-01

    A few days earlier than usual, a large, dense plume of dust blew southward and eastward from the desert plains of Mongolia-quite smothering to the residents of Beijing. Citizens of northeastern China call this annual event the 'shachenbao,' or 'dust cloud tempest.' However, the tempest normally occurs during the spring time. The dust storm hit Beijing on Friday night, March 15, and began coating everything with a fine, pale brown layer of grit. The region is quite dry; a problem some believe has been exacerbated by decades of deforestation. According to Chinese government estimates, roughly 1 million tons of desert dust and sand blow into Beijing each year. This true-color image was made using two adjacent swaths (click to see the full image) of data from the Sea-viewing Wide Field-of-view Sensor (SeaWiFS), flying aboard the OrbView-2 satellite, on March 17, 2002. The massive dust storm (brownish pixels) can easily be distinguished from clouds (bright white pixels) as it blows across northern Japan and eastward toward the open Pacific Ocean. The black regions are gaps between SeaWiFS' viewing swaths and represent areas where no data were collected. Image courtesy the SeaWiFS Project, NASA/Goddard Space Flight Center, and ORBIMAGE

  1. A superposed epoch analysis of geomagnetic storms

    Directory of Open Access Journals (Sweden)

    J. R. Taylor

    1994-06-01

    Full Text Available A superposed epoch analysis of geomagnetic storms has been undertaken. The storms are categorised via their intensity (as defined by the Dst index. Storms have also been classified here as either storm sudden commencements (SSCs or storm gradual commencements (SGCs, that is all storms which did not begin with a sudden commencement. The prevailing solar wind conditions defined by the parameters solar wind speed (vsw, density (ρsw and pressure (Psw and the total field and the components of the interplanetary magnetic field (IMF during the storms in each category have been investigated by a superposed epoch analysis. The southward component of the IMF, appears to be the controlling parameter for the generation of small SGCs (-100 nT< minimum Dst ≤ -50 nT for ≥ 4 h, but for SSCs of the same intensity solar wind pressure is dominant. However, for large SSCs (minimum Dst ≤ -100 nT for ≥ 4 h the solar wind speed is the controlling parameter. It is also demonstrated that for larger storms magnetic activity is not solely driven by the accumulation of substorm activity, but substantial energy is directly input via the dayside. Furthermore, there is evidence that SSCs are caused by the passage of a coronal mass ejection, whereas SGCs result from the passage of a high speed/ slow speed coronal stream interface. Storms are also grouped by the sign of Bz during the first hour epoch after the onset. The sign of Bz at t = +1 h is the dominant sign of the Bz for ~24 h before the onset. The total energy released during storms for which Bz was initially positive is, however, of the same order as for storms where Bz was initially negative.

  2. Water Quality of Combined Sewer Overflows, Stormwater, and Streams, Omaha, Nebraska, 2006-07

    Science.gov (United States)

    Vogel, Jason R.; Frankforter, Jill D.; Rus, David L.; Hobza, Christopher M.; Moser, Matthew T.

    2009-01-01

    The U.S. Geological Survey, in cooperation with the City of Omaha, investigated the water quality of combined sewer overflows, stormwater, and streams in the Omaha, Nebraska, area by collecting and analyzing 1,175 water samples from August 2006 through October 2007. The study area included the drainage area of Papillion Creek at Capeheart Road near Bellevue, Nebraska, which encompasses the tributary drainages of the Big and Little Papillion Creeks and Cole Creek, along with the Missouri River reach that is adjacent to Omaha. Of the 101 constituents analyzed during the study, 100 were detected in at least 1 sample during the study. Spatial and seasonal comparisons were completed for environmental samples. Measured concentrations in stream samples were compared to water-quality criteria for pollutants of concern. Finally, the mass loads of water-quality constituents in the combined sewer overflow discharges, stormwater outfalls, and streams were computed and compared. The results of the study indicate that combined sewer overflow and stormwater discharges are affecting the water quality of the streams in the Omaha area. At the Papillion Creek Basin sites, Escherichia coli densities were greater than 126 units per 100 milliliters in 99 percent of the samples (212 of 213 samples analyzed for Escherichia coli) collected during the recreational-use season from May through September (in 2006 and 2007). Escherichia coli densities in 76 percent of Missouri River samples (39 of 51 samples) were greater than 126 units per 100 milliliters in samples collected from May through September (in 2006 and 2007). None of the constituents with human health criteria for consumption of water, fish, and other aquatic organisms were detected at levels greater than the criteria in any of the samples collected during this study. Total phosphorus concentrations in water samples collected in the Papillion Creek Basin were in excess of the U.S. Environmental Protection Agency's proposed

  3. Reconnaissance level study Mississippi storm surge barrier

    NARCIS (Netherlands)

    Van Ledden, M.; Lansen, A.J.; De Ridder, H.A.J.; Edge, B.

    2012-01-01

    This paper reports a reconnaissance level study of a storm surge barrier in the Mississippi River. Historical hurricanes have shown storm surge of several meters along the Mississippi River levees up to and upstream of New Orleans. Future changes due to sea level rise and subsidence will further

  4. The evaluation and management of electrical storm.

    Science.gov (United States)

    Eifling, Michael; Razavi, Mehdi; Massumi, Ali

    2011-01-01

    Electrical storm is an increasingly common and life-threatening syndrome that is defined by 3 or more sustained episodes of ventricular tachycardia, ventricular fibrillation, or appropriate shocks from an implantable cardioverter-defibrillator within 24 hours. The clinical presentation can be dramatic. Electrical storm can manifest itself during acute myocardial infarction and in patients who have structural heart disease, an implantable cardioverter-defibrillator, or an inherited arrhythmic syndrome. The presence or absence of structural heart disease and the electrocardiographic morphology of the presenting arrhythmia can provide important diagnostic clues into the mechanism of electrical storm. Electrical storm typically has a poor outcome.The effective management of electrical storm requires an understanding of arrhythmia mechanisms, therapeutic options, device programming, and indications for radiofrequency catheter ablation. Initial management involves determining and correcting the underlying ischemia, electrolyte imbalances, or other causative factors. Amiodarone and β-blockers, especially propranolol, effectively resolve arrhythmias in most patients. Nonpharmacologic treatment, including radiofrequency ablation, can control electrical storm in drug-refractory patients. Patients who have implantable cardioverter-defibrillators can present with multiple shocks and may require drug therapy and device reprogramming. After the acute phase of electrical storm, the treatment focus should shift toward maximizing heart-failure therapy, performing revascularization, and preventing subsequent ventricular arrhythmias. Herein, we present an organized approach for effectively evaluating and managing electrical storm.

  5. Normothermic thyroid storm: an unusual presentation

    Science.gov (United States)

    Sabir, Anas Ahmad; Sada, Kabiru; Yusuf, Bashir O.; Aliyu, Idris

    2016-01-01

    Thyroid storm is a rare life-threatening emergency due to thyrotoxicosis. A 30-year-old female presented with restlessness, tachycardia and vomiting but with normothermia which is an unusual presentation. There is the need for clinicians to be aware of atypical clinical features that can make the diagnosis of thyroid storm difficult. PMID:27540465

  6. Predicting the occurrence of super-storms

    Directory of Open Access Journals (Sweden)

    N. Srivastava

    2005-11-01

    Full Text Available A comparative study of five super-storms (Dst<-300 nT of the current solar cycle after the launch of SoHO, to identify solar and interplanetary variables that influence the magnitude of resulting geomagnetic storms, is described. Amongst solar variables, the initial speed of a CME is considered the most reliable predictor of the strength of the associated geomagnetic storm because fast mass ejections are responsible for building up the ram pressure at the Earth's magnetosphere. However, although most of the super-storms studied were associated with high speed CMEs, the Dst index of the resulting geomagnetic storms varied between -300 to -472 nT. The most intense storm of 20 November 2003, (Dst ~ -472 nT had its source in a comparatively smaller active region and was associated with a relatively weaker, M-class flare while all other super-storms had their origins in large active regions and were associated with strong X-class flares. However, this superstorm did not show any associated extraordinary solar and interplanetary characteristics. The study also reveals the challenge in the reliable prediction of the magnitude of a geomagnetic storm from solar and interplanetary variables.

  7. Predicting the occurrence of super-storms

    Directory of Open Access Journals (Sweden)

    N. Srivastava

    2005-11-01

    Full Text Available A comparative study of five super-storms (Dst<-300 nT of the current solar cycle after the launch of SoHO, to identify solar and interplanetary variables that influence the magnitude of resulting geomagnetic storms, is described. Amongst solar variables, the initial speed of a CME is considered the most reliable predictor of the strength of the associated geomagnetic storm because fast mass ejections are responsible for building up the ram pressure at the Earth's magnetosphere. However, although most of the super-storms studied were associated with high speed CMEs, the Dst index of the resulting geomagnetic storms varied between -300 to -472 nT. The most intense storm of 20 November 2003, (Dst ~ -472 nT had its source in a comparatively smaller active region and was associated with a relatively weaker, M-class flare while all other super-storms had their origins in large active regions and were associated with strong X-class flares. However, this superstorm did not show any associated extraordinary solar and interplanetary characteristics. The study also reveals the challenge in the reliable prediction of the magnitude of a geomagnetic storm from solar and interplanetary variables.

  8. Storm Sewage Dilution in Smaller Streams

    DEFF Research Database (Denmark)

    Larsen, Torben; Vestergaard, Kristian

    1987-01-01

    A numerical model has been used to show how dilution in smaller streams can be effected by unsteady hydraulic conditions caused by a storm sewage overflow.......A numerical model has been used to show how dilution in smaller streams can be effected by unsteady hydraulic conditions caused by a storm sewage overflow....

  9. Living with storm damage to forests

    NARCIS (Netherlands)

    Gardiner, B.; Schuck, A.; Schelhaas, M.J.; Orazio, C.; Blennow, K.; Nicoll, B.

    2013-01-01

    Windstorms are a major disturbance factor for European forests. In the past six decades wind storms have damaged standing forest volume, which on a yearly average equals about the size of Poland's annual fellings. The evedence also indicates that the actual severity of storms in the wake of climatic

  10. Storm real-time processing cookbook

    CERN Document Server

    Anderson, Quinton

    2013-01-01

    A Cookbook with plenty of practical recipes for different uses of Storm.If you are a Java developer with basic knowledge of real-time processing and would like to learn Storm to process unbounded streams of data in real time, then this book is for you.

  11. Electrical storm: clinical manifestations and management.

    Science.gov (United States)

    Littmann, L; Rennyson, S L

    2007-10-01

    Electrical storm is the clustering of hemodynamically destabilizing ventricular tachycardia or ventricular fibrillation that typically requires multiple electrical cardioversions or defibrillations within a 24-hour period. Electrical storm is frequently seen in the acute phase of myocardial infarction, in patients with the genetic arrhythmia syndromes, and in patients with implanted cardioverters-defibrillators. The evaluation and management should focus on the immediate suppression of the arrhythmia, a search for possible reversible causes, and attempts to prevent recurrences. In this review we present the most common conditions associated with electrical storm, therapeutic options for suppression of electrical storm, and new investigational techniques emerging for the treatment of electrical storm in refractory cases. The management of this life threatening arrhythmia typically requires the coordinated efforts of emergency medicine, critical care, cardiology, cardiac electrophysiology, and pacemaker experts.

  12. Thyroid storm precipitated by acute biliary pancreatitis

    Directory of Open Access Journals (Sweden)

    Mehrdad Karimi

    2017-01-01

    Full Text Available Thyroid storm is an acute, life-threatening exacerbation and sudden releasing large amounts of thyroid hormone in a short period of time. Nevertheless, critical aggravation of hyperthyroidism typically resulted from concurrent disorder. Synchronous management of thyroid storm along with its precipitant, such as infection is recommended. We described the case of an acute biliary pancreatitis complicated with a thyroid storm. The patient was successfully managed with a quick surgical intervention and further critical care for thyroid storm. Although it is widely believed that pancreatitis is seldom concurrent with thyrotoxicosis, thyroid storm can be precipitated by a variety of factors, including intra-abdominal infections such as acute pancreatitis or perforated peptic ulcer. In conclusion, acute pancreatitis in patients with thyrotoxicosis seems to be extremely rare, but such patients should be managed intensively against underlying thyroid disorders as well as pancreatitis.

  13. Physical and Chemical Characterization of Fat and Oil Deposits in Mashhad City Sewer Lines and the Solutions Developed

    Directory of Open Access Journals (Sweden)

    Mahdi kamali

    2017-01-01

    Full Text Available Formation of oil, fat, and grease deposits in sewer pipelines is a major concern as they result in sewage overflow and pose health problems. Analysis of two sample deposits collected from the sewer lines of Imam Reza Street in the city of Mashhad suggested that the chemical reactions promoted by edible oils in the sewer lines lead to the formation of insoluble soap and deposits. Being sticky, the deposits accumulate over time to eventually block the lines. The analysis also showed that the moisture content of the samples ranged between 50‒62%, indicating that water does not play a main role in their formation. The samples were also found to contain 61.78% and 84.35% saturated fatty acids, with palmitic acid being the dominant one. Calcium was the main metal in the samples, which is due to both water hardness and corrosion of the sewer lines. Based on the results obtained, the origin of these deposits, and the relevant protocols for the management of oil and fat wastes, solutions were proposed to prevent deposit formation and sewer line clogging that suit the special cultural and environmental conditions of the city. These proposals are under consideration for implementation in the region.

  14. Understanding the spatial formation and accumulation of fats, oils and grease deposits in the sewer collection system.

    Science.gov (United States)

    Dominic, Christopher Cyril Sandeep; Szakasits, Megan; Dean, Lisa O; Ducoste, Joel J

    2013-01-01

    Sanitary sewer overflows are caused by the accumulation of insoluble calcium salts of fatty acids, which are formed by the reaction between fats, oils and grease (FOG) and calcium found in wastewaters. Different sewer structural configurations (i.e., manholes, pipes, wet wells), which vary spatially, along with other obstructions (roots intrusion) and pipe deformations (pipe sags), may influence the detrimental buildup of FOG deposits. The purpose of this study was to quantify the spatial variation in FOG deposit formation and accumulation in a pilot-scale sewer collection system. The pilot system contained straight pipes, manholes, roots intrusion, and a pipe sag. Calcium and oil were injected into the system and operated at alkaline (pH = 10) and neutral (pH = 7) pH conditions. Results showed that solid accumulations were slightly higher at neutral pH. Fourier transform infrared (FTIR) analysis on the solids samples confirmed that the solids were indeed calcium-based fatty acid salts. However, the fatty acid profiles of the solids deviated from the profile found from FOG deposits in sewer systems, which were primarily saturated fatty acids. These results confirm the work done previously by researchers and suggest an alternative fate of unsaturated fatty acids that does not lead to their incorporation in FOG deposits in full-scale sewer systems.

  15. Dust Storm Hits Canary Islands

    Science.gov (United States)

    2002-01-01

    A thick pall of sand and dust blew out from the Sahara Desert over the Atlantic Ocean yesterday (January 6, 2002), engulfing the Canary Islands in what has become one of the worst sand storms ever recorded there. In this scene, notice how the dust appears particularly thick in the downwind wake of Tenerife, the largest of the Canary Islands. Perhaps the turbulence generated by the air currents flowing past the island's volcanic peaks is churning the dust back up into the atmosphere, rather than allowing it to settle toward the surface. This true-color image was captured by the Moderate-resolution Imaging Spectroradiometer (MODIS), flying aboard NASA's Terra satellite, on January 7, 2002. Image courtesy Jacques Descloitres, MODIS Land Rapid Response Team at NASA GSFC

  16. Copper disinfection ban causes storm.

    Science.gov (United States)

    Lester, Alan

    2013-05-01

    Since 1 February this year, under the EU's Biocidal Products Directive, it has been illegal to sell or use water treatment systems that use elemental copper, a practice employed historically by a significant number of UK healthcare facilities to combat Legionella. Alan Lester, managing director of specialist supplier of 'environmentally-friendly' water treatment systems, Advanced Hydro, says the ban has caused 'a storm of giant proportion,' with advocates of copper ion-based treatment systems arguing that this disinfection method dates back 3,000 years to Egyptian times, making it an 'undoubtedly proven' technology. Here he explains why the ban came into force, considers why the UK's Health and Safety Executive (HSE) is seeking a derogation, looks at the ban's likely impact, and gives a personal viewpoint on the 'pros and cons' of some of the alternative treatment technologies, including a titanium dioxide-based system marketed by Advanced Hydro itself in the UK.

  17. Predicting severe winter coastal storm damage

    International Nuclear Information System (INIS)

    Hondula, David M; Dolan, Robert

    2010-01-01

    Over the past 40 years residents of, and visitors to, the North Carolina coastal barrier islands have experienced the destructive forces of several 'named' extratropical storms. These storms have caused large-scale redistributions of sand and loss of coastal structures and infrastructure. While most of the population living on the islands are familiar with the wintertime storms, the damage and scars of the 'super northeasters'-such as the Ash Wednesday storm of 7 March 1962, and the Halloween storm of 1989-are slipping away from the public's memory. In this research we compared the damage zones of the 1962 Ash Wednesday storm, as depicted on aerial photographs taken after the storm, with photos taken of the same areas in 2003. With these high-resolution aerial photos we were able to estimate the extent of new development which has taken place along the Outer Banks of North Carolina since 1962. Three damage zones were defined that extend across the islands from the ocean landward on the 1962 aerial photos: (1) the zone of almost total destruction on the seaward edge of the islands where the storm waves break; (2) the zone immediately inland where moderate structural damage occurs during severe storms; and (3) the zone of flood damage at the landward margin of the storm surge and overwash. We considered the rate of coastal erosion, the rate of development, and increases in property values as factors which may contribute to changing the financial risk for coastal communities. In comparing the values of these four factors with the 1962 damage data, we produced a predicted dollar value for storm damage should another storm of the magnitude of the 1962 Ash Wednesday storm occur in the present decade. This model also provides an opportunity to estimate the rate of increase in the potential losses through time as shoreline erosion continues to progressively reduce the buffer between the development and the edge of the sea. Our data suggest that the losses along the North

  18. Predicting severe winter coastal storm damage

    Energy Technology Data Exchange (ETDEWEB)

    Hondula, David M; Dolan, Robert, E-mail: hondula@virginia.edu [Department of Environmental Sciences, University of Virginia, PO Box 400123, Charlottesville, VA 22903 (United States)

    2010-07-15

    Over the past 40 years residents of, and visitors to, the North Carolina coastal barrier islands have experienced the destructive forces of several 'named' extratropical storms. These storms have caused large-scale redistributions of sand and loss of coastal structures and infrastructure. While most of the population living on the islands are familiar with the wintertime storms, the damage and scars of the 'super northeasters'-such as the Ash Wednesday storm of 7 March 1962, and the Halloween storm of 1989-are slipping away from the public's memory. In this research we compared the damage zones of the 1962 Ash Wednesday storm, as depicted on aerial photographs taken after the storm, with photos taken of the same areas in 2003. With these high-resolution aerial photos we were able to estimate the extent of new development which has taken place along the Outer Banks of North Carolina since 1962. Three damage zones were defined that extend across the islands from the ocean landward on the 1962 aerial photos: (1) the zone of almost total destruction on the seaward edge of the islands where the storm waves break; (2) the zone immediately inland where moderate structural damage occurs during severe storms; and (3) the zone of flood damage at the landward margin of the storm surge and overwash. We considered the rate of coastal erosion, the rate of development, and increases in property values as factors which may contribute to changing the financial risk for coastal communities. In comparing the values of these four factors with the 1962 damage data, we produced a predicted dollar value for storm damage should another storm of the magnitude of the 1962 Ash Wednesday storm occur in the present decade. This model also provides an opportunity to estimate the rate of increase in the potential losses through time as shoreline erosion continues to progressively reduce the buffer between the development and the edge of the sea. Our data suggest that the

  19. Predicting severe winter coastal storm damage

    Science.gov (United States)

    Hondula, David M.; Dolan, Robert

    2010-07-01

    Over the past 40 years residents of, and visitors to, the North Carolina coastal barrier islands have experienced the destructive forces of several 'named' extratropical storms. These storms have caused large-scale redistributions of sand and loss of coastal structures and infrastructure. While most of the population living on the islands are familiar with the wintertime storms, the damage and scars of the 'super northeasters'—such as the Ash Wednesday storm of 7 March 1962, and the Halloween storm of 1989—are slipping away from the public's memory. In this research we compared the damage zones of the 1962 Ash Wednesday storm, as depicted on aerial photographs taken after the storm, with photos taken of the same areas in 2003. With these high-resolution aerial photos we were able to estimate the extent of new development which has taken place along the Outer Banks of North Carolina since 1962. Three damage zones were defined that extend across the islands from the ocean landward on the 1962 aerial photos: (1) the zone of almost total destruction on the seaward edge of the islands where the storm waves break; (2) the zone immediately inland where moderate structural damage occurs during severe storms; and (3) the zone of flood damage at the landward margin of the storm surge and overwash. We considered the rate of coastal erosion, the rate of development, and increases in property values as factors which may contribute to changing the financial risk for coastal communities. In comparing the values of these four factors with the 1962 damage data, we produced a predicted dollar value for storm damage should another storm of the magnitude of the 1962 Ash Wednesday storm occur in the present decade. This model also provides an opportunity to estimate the rate of increase in the potential losses through time as shoreline erosion continues to progressively reduce the buffer between the development and the edge of the sea. Our data suggest that the losses along the

  20. Electrochemical oxidation of iron and alkalinity generation for efficient sulfide control in sewers.

    Science.gov (United States)

    Lin, Hui-Wen; Kustermans, Caroline; Vaiopoulou, Eleni; Prévoteau, Antonin; Rabaey, Korneel; Yuan, Zhiguo; Pikaar, Ilje

    2017-07-01

    The addition of iron salts is one of the most commonly used dosing strategies for sulfide control in sewers. However, iron salts decrease the sewage pH which not only reduces the effectiveness of sulfide precipitation but also enhances the release of residual sulfide to the sewer atmosphere. Equally important, concentrated iron salt solutions are corrosive and their frequent transport, handling, and on-site storage often come with Occupational Health and Safety (OH&S) concerns. Here, we experimentally demonstrated a novel sulfide control approach using electrochemical systems with parallel placed iron electrodes. This enabled combining anodic dissolved iron species release with cathodic hydroxyl anion production, which alleviates all the aforementioned concerns. A long-term experiment was successfully carried out achieving an average sulfide removal efficiency of 95.4 ± 4.4% at low voltage input of 2.90 ± 0.54 V over the course of 8 weeks. This electrochemical method was demonstrated to successfully achieve efficient sulfide control. In addition, it increases the sewage pH, thereby overcoming the drawbacks associated with the pH decrease in the case of conventional iron salt dosing. Ferrous ions were produced at an overall coulombic efficiency (CE) of 98.2 ± 1.2%, whereas oxygen evolution and direct sulfide oxidation were not observed. Short-term experiments showed that increasing either inter-electrode gap or current density increased the cell voltage associated with the increase in the ohmic drop of the system. Overall, this study highlights the practical potential of in-situ generation of dissolved iron species and simultaneous hydroxyl anion generation for efficient sulfide control in sewers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Geometric effects of ICMEs on geomagnetic storms

    Science.gov (United States)

    Cho, KyungSuk; Lee, Jae-Ok

    2017-04-01

    It has been known that the geomagnetic storm is occurred by the interaction between the Interplanetary Coronal Mass Ejection (ICME) and the Earth's magnetosphere; especially, the southward Bz component of ICME is thought as the main trigger. In this study, we investigate the relationship between Dst index and solar wind conditions; which are the southward Bz, electric field (VBz), and time integral of electric field as well as ICME parameters derived from toroidal fitting model in order to find what is main factor to the geomagnetic storm. We also inspect locations of Earth in ICMEs to understand the geometric effects of the Interplanetary Flux Ropes (IFRs) on the geomagnetic storms. Among 59 CDAW ICME lists, we select 30 IFR events that are available by the toroidal fitting model and classify them into two sub-groups: geomagnetic storms associated with the Magnetic Clouds (MCs) and the compression regions ahead of the MCs (sheath). The main results are as follows: (1) The time integral of electric field has a higher correlation coefficient (cc) with Dst index than the other parameters: cc=0.85 for 25 MC events and cc=0.99 for 5 sheath events. (2) The sheath associated intense storms (Dst ≤-100nT) having usually occur at flank regions of ICMEs while the MC associated intense storms occur regardless of the locations of the Earth in ICMEs. The strength of a geomagnetic storm strongly depends on electric field of IFR and durations of the IFR passages through the Earth.

  2. Dopant-assisted negative photoionization Ion mobility spectrometry coupled with on-line cooling inlet for real-time monitoring H2S concentration in sewer gas.

    Science.gov (United States)

    Peng, Liying; Jiang, Dandan; Wang, Zhenxin; Hua, Lei; Li, Haiyang

    2016-06-01

    Malodorous hydrogen sulfide (H2S) gas often exists in the sewer system and associates with the problems of releasing the dangerous odor to the atmosphere and causing sewer pipe to be corroded. A simple method is in demand for real-time measuring H2S level in the sewer gas. In this paper, an innovated method based on dopant-assisted negative photoionization ion mobility spectrometry (DANP-IMS) with on-line semiconductor cooling inlet was put forward and successfully applied for the real-time measurement of H2S in sewer gas. The influence of moisture was effectively reduced via an on-line cooling method and a non-equilibrium dilution with drift gas. The limits of quantitation for the H2S in ≥60% relative humidity air could be obtained at ≤79.0ng L(-1) with linear ranges of 129-2064ng L(-1). The H2S concentration in a sewer manhole was successfully determined while its product ions were identified by an ion-mobility time-of-fight mass spectrometry. Finally, the correlation between sewer H2S concentration and the daily routines and habits of residents was investigated through hourly or real-time monitoring the variation of sewer H2S in manholes, indicating the power of this DANP-IMS method in assessing the H2S concentration in sewer system. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Prioritising sewerage maintenance using inferred sewer age: a case study for Edinburgh.

    Science.gov (United States)

    Arthur, S; Burkhard, R

    2010-01-01

    The reported research project focuses on using a database which contains details of customer contacts and CCTV data for a key Scottish catchment to construct a GIS based sewer condition model. Given the nature of the asset registry, a key research challenge was estimating the age of individual lengths of pipe. Within this context, asset age was inferred using the estimated age of surface developments-this involved overlaying the network in a GIS with historical digital maps. The paper illustrates that inferred asset age can reliably be used to highlight assets which are more likely to fail.

  4. Reliability of adaptive multivariate software sensors for sewer water quality monitoring

    DEFF Research Database (Denmark)

    Vezzaro, Luca; Mikkelsen, Peter Steen

    2015-01-01

    This study investigates the use of a multivariate approach, based on Principal Component Analysis PCA), as software sensor for fault detection and reconstruction of missing measurements in on-line monitoring of sewer water quality. The analysis was carried out on a 16-months dataset of five...... commonly available on-line measurements (flow, turbidity, ammonia, conductivity and temperature). The results confirmed the great performance of PCA (up to 10 weeks after parameter estimation) when estimating a measurement from the combination of the remaining four variables, a useful feature in data...

  5. Chemical disinfection of combined sewer overflow waters using performic acid or peracetic acids

    OpenAIRE

    Chhetri, Ravi Kumar; Thornberg, Dines; Berner, Jesper; Gramstad, Robin; Öjstedt, Ulrik; Sharma, Anitha Kumari; Andersen, Henrik Rasmus

    2014-01-01

    We investigated the possibility of applying performic acid (PFA) and peracetic acid (PAA) for disinfection of combined sewer overflow (CSO) in existing CSO management infrastructures. The disinfection power of PFA and PAA towards Escherichia coli (E. coli) and Enterococcus was studied in batch-scale and pre-field experiments. In the batch-scale experiment, 2.5 mg L− 1 PAA removed approximately 4 log unit of E. coli and Enterococcus from CSO with a 360 min contact time. The removal of E. coli ...

  6. Combined Sewer Overflow pretreatment with chemical coagulation and a particle settler for improved peracetic acid disinfection

    DEFF Research Database (Denmark)

    Chhetri, Ravi Kumar; Bonnerup, Arne; Andersen, Henrik Rasmus

    2016-01-01

    Full scale disinfection by peracetic acid (PAA) was achieved on Combined Sewer Overflow (CSO) water, which was pre-treated physically by a fast settling-filtration unit. Disinfection of untreated CSO water using PAA was compared to treatment using a particle separator (Hydro......Separator®) and additional coagulation with poly-aluminum-chloride. Disinfection for Enterococcus increased with the applied dose of PAA and additional improvement was achieved when it was preceded by chemical coagulation with 5 mg L−1 poly-aluminum-chloride. When Enterococcus was reduced by treatment in the Hydro...

  7. Micropollutants in stormwater runoff and combined sewer overflow in the Copenhagen area, Denmark

    DEFF Research Database (Denmark)

    Birch, Heidi; Mikkelsen, Peter Steen; Jensen, J.K.

    2011-01-01

    Stormwater runoff contains a broad range of micropollutants. In Europe a number of these substances are regulated through the Water Framework Directive, which establishes Environmental Quality Standards (EQSs) for surface waters. Knowledge about discharge of these substances through stormwater...... runoff and combined sewer overflows (CSOs) is essential to ensure compliance with the EQSs. Results from a screening campaign including more than 50 substances at four stormwater discharge locations and one CSO in Copenhagen are reported here. Heavy metal concentrations were detected at levels similar...

  8. The Use of Intelligent Relays for the Sewer Cleaning Vehicle Control and Automation

    Directory of Open Access Journals (Sweden)

    O. Chiver

    2012-06-01

    Full Text Available The paper presents the way in which the electrical control and automation system of the 5 mc combined sewer and gully cleaning vehicle equipped by a local company was designed, using the intelligent relay of the easy 700 type of Moeller (Eaton company. The control of all the equipments is performed locally from the control panel and some of them can also by remote controlled by means of the radio waves. The program required by the intelligent relay was created, tested and implemented with the help of the dedicated software easy-soft 6, developed by the manufacturing company.

  9. Quantitative and qualitative hydrologic balance for a suburban watershed with a separate sewer system (Nantes, France).

    Science.gov (United States)

    Ruban, V; Larrarte, F; Berthier, M; Favreau, L; Sauvourel, Y; Letellier, L; Mosisni, M L; Raimbault, G

    2005-01-01

    A qualitative and quantitative budget at the outlet of the storm-water runoff system of a small suburban watershed is presented together with some data regarding waste-water. 445,000 m3 (34% of the rain-water volume) were drained by the storm-water runoff system and 40,879 m3 by the waste-water system from September 2002 to March 2004. Storm-water runoff is generally not heavily polluted with regard to trace metals but concentrations occasionally exceed the standards for surface water of good quality. On the contrary, pesticides (diuron and glyphosate) have very high concentrations especially in spring and autumn when their use is maximum. As the St Joseph storm-water runoff is finally discharged into the Erdre River, measures to reduce the use of these pollutants should be considered.

  10. Remaining Sites Verification Package for the 1607-F3 Sanitary Sewer System, Waste Site Reclassification Form 2006-047

    Energy Technology Data Exchange (ETDEWEB)

    L. M. Dittmer

    2007-04-26

    The 1607-F3 waste site is the former location of the sanitary sewer system that supported the 182-F Pump Station, the 183-F Water Treatment Plant, and the 151-F Substation. The sanitary sewer system included a septic tank, drain field, and associated pipeline, all in use between 1944 and 1965. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling demonstrated that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also showed that residual contaminant concentrations are protective of groundwater and the Columbia River.

  11. Half saturation constants for nitrate and nitrite by in-sewer anoxic transformations of wastewater organic matter

    DEFF Research Database (Denmark)

    Abdul-Talib, Suhaimi; Hvitved-Jacobsen, Thorkild; Vollertsen, Jes

    2001-01-01

     significant breakthrough and progress have been made in the study of the kinetics of microbial transformation in sewers under aerobic and under changing aerobic/anaerobic conditions. Fundamental knowledge on anoxic kinetics of wastewater is still lacking, so it is not now possible to apply...... an integrated approach to municipal wastewater treatment incorporating sewer networks as a bio-chemical reactor. This paper presents the results of studies on determining half saturation constants for nitrate, KNO3, and nitrite, KNO2, in raw wastewater. The average values of KNO3 and KNO2, determined from...

  12. Water Pumping Stations, File name = UTILITIES - PARTIAL Data is incomplete. Contains electric trans lines, electric substations, sewer plants, sewer pumpstations, water plants, water tanks http://www.harfordcountymd.gov/gis/Index.cfm, Published in 2011, 1:1200 (1in=100ft) scale, Harford County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Water Pumping Stations dataset current as of 2011. File name = UTILITIES - PARTIAL Data is incomplete. Contains electric trans lines, electric substations, sewer...

  13. Sewerage Pumping Stations, File name = UTILITIES - PARTIAL Data is incomplete. Contains electric trans lines, electric substations, sewer plants, sewer pumpstations, water plants, water tanks http://www.harfordcountymd.gov/gis/Index.cfm, Published in 2011, 1:600 (1in=50ft) scale, Harford County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Sewerage Pumping Stations dataset current as of 2011. File name = UTILITIES - PARTIAL Data is incomplete. Contains electric trans lines, electric substations, sewer...

  14. Calibration Transfer Between a Bench Scanning and a Submersible Diode Array Spectrophotometer for In Situ Wastewater Quality Monitoring in Sewer Systems.

    Science.gov (United States)

    Brito, Rita S; Pinheiro, Helena M; Ferreira, Filipa; Matos, José S; Pinheiro, Alexandre; Lourenço, Nídia D

    2016-03-01

    Online monitoring programs based on spectroscopy have a high application potential for the detection of hazardous wastewater discharges in sewer systems. Wastewater hydraulics poses a challenge for in situ spectroscopy, especially when the system includes storm water connections leading to rapid changes in water depth, velocity, and in the water quality matrix. Thus, there is a need to optimize and fix the location of in situ instruments, limiting their availability for calibration. In this context, the development of calibration models on bench spectrophotometers to estimate wastewater quality parameters from spectra acquired with in situ instruments could be very useful. However, spectra contain information not only from the samples, but also from the spectrophotometer generally invalidating this approach. The use of calibration transfer methods is a promising solution to this problem. In this study, calibration models were developed using interval partial least squares (iPLS), for the estimation of total suspended solids (TSS) and chemical oxygen demand (COD) in sewage from Ultraviolet-visible spectra acquired in a bench scanning spectrophotometer. The feasibility of calibration transfer to a submersible, diode array equipment, to be subsequently operated in situ, was assessed using three procedures: slope and bias correction (SBC); single wavelength standardization (SWS) on mean spectra; and local centering (LC). The results showed that SBC was the most adequate for the available data, adding insignificant error to the base model estimates. Single wavelength standardization was a close second best, potentially more robust, and independent of the base iPLS model. Local centering was shown to be inadequate for the samples and instruments used. © The Author(s) 2016.

  15. Rain storm models and the relationship between their parameters

    NARCIS (Netherlands)

    Stol, P.T.

    1977-01-01

    Rainfall interstation correlation functions can be obtained with the aid of analytic rainfall or storm models. Since alternative storm models have different mathematical formulas, comparison should be based on equallity of parameters like storm diameter, mean rainfall amount, storm maximum or total

  16. 46 CFR 72.40-10 - Storm rails.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Storm rails. 72.40-10 Section 72.40-10 Shipping COAST... and Guards § 72.40-10 Storm rails. (a) Suitable storm rails shall be installed in all passageways and at the deckhouse sides where passengers or crew might have normal access. Storm rails shall be...

  17. Hindicast and forecast of the Parsifal storm

    Energy Technology Data Exchange (ETDEWEB)

    Bertotti, L.; Cavaleri, L. [Istituto Studio Dinamica Grandi Masse, Venice (Italy); De girolamo, P.; Magnaldi, S. [Rome, Univ. `La Sapienza` (Italy). Dip. di Idraulica, Trasporti e Strade; Franco, L. [Rome, III Univ. (Italy). Dip. di Scienze dell`Ingegneria Civile

    1998-05-01

    On 2 November 1995 a Mistral storm in the Gulf of Lions sank the 16 metre yacht Parsifal claiming six lives out of the nine member crew. The authors analyse the storm with different meteorological and wave models, verifying the results against the available buoy and satellite measurements. Then the authors consider the accuracy of the storm forecasts and the information available the days before the accident. The limitations related to the resolution of the meteorological models are explored by hind casting the storm also with the winds produced by some limited area models. Finally, the authors discuss the present situation of wind and wave hind cast and forecast in the Mediterranean Sea, and the distribution of these results to the public.

  18. Storm Water General Permit 2 for Construction

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — General permit #2 for storm water discharges associated with industrial activity for Construction Activities in Iowa for the National Pollutant Discharge Elimination...

  19. Nuclear magnetohydrodynamic EMP, solar storms, and substorms

    International Nuclear Information System (INIS)

    Rabinowitz, M.; Meliopoulous, A.P.S.; Glytsis, E.N.

    1992-01-01

    In addition to a fast electromagnetic pulse (EMP), a high altitude nuclear burst produces a relatively slow magnetohydrodynamic EMP (MHD EMP), whose effects are like those from solar storm geomagnetically induced currents (SS-GIC). The MHD EMP electric field E approx-lt 10 - 1 V/m and lasts approx-lt 10 2 sec, whereas for solar storms E approx-gt 10 - 2 V/m and lasts approx-gt 10 3 sec. Although the solar storm electric field is lower than MHD EMP, the solar storm effects are generally greater due to their much longer duration. Substorms produce much smaller effects than SS-GIC, but occur much more frequently. This paper describes the physics of such geomagnetic disturbances and analyzes their effects

  20. Joint Typhoon Warning Center (JTWC) Storm Wallets

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Joint Typhoon Warning Center (JTWC) is responsible for typhoon forecasts and warnings for the Western Pacific and Indian Ocean basins. After each storm, the JTWC...

  1. Storm Water BMP Tool Implementation Testing

    Science.gov (United States)

    2017-12-01

    Under project 2015-ORIL 7, a screening tool was developed to assist Local communities with selecting post-construction storm water best management practices (BMPs) to comply with the Ohio Environmental Protection Agencys (Ohio EPA) statewide Const...

  2. Ionospheric behaviour during storm recovery phase

    Science.gov (United States)

    Buresova, D.; Lastovicka, J.; Boska, J.; Sindelarova, T.; Chum, J.

    2012-04-01

    Intensive ionospheric research, numerous multi-instrumental observations and large-scale numerical simulations of ionospheric F region response to magnetic storm-induced disturbances during the last several decades were primarily focused on the storm main phase, in most cases covering only a few hours of the recovery phase following after storm culmination. Ionospheric behaviour during entire recovery phase still belongs to not sufficiently explored and hardly predictable features. In general, the recovery phase is characterized by an abatement of perturbations and a gradual return to the "ground state" of ionosphere. However, observations of stormy ionosphere show significant departures from the climatology also within this phase. This paper deals with the quantitative and qualitative analysis of the ionospheric behaviour during the entire recovery phase of strong-to-severe magnetic storms at middle latitudes for nowadays and future modelling and forecasting purposes.

  3. Geomagnetic storms, super-storms, and their impacts on GPS-based navigation systems

    Science.gov (United States)

    Astafyeva, E.; Yasyukevich, Yu.; Maksikov, A.; Zhivetiev, I.

    2014-07-01

    Using data of GPS receivers located worldwide, we analyze the quality of GPS performance during four geomagnetic storms of different intensity: two super-storms and two intense storms. We show that during super-storms the density of GPS Losses-of-Lock (LoL) increases up to 0.25% at L1 frequency and up to 3% at L2 frequency, and up to 0.15% (at L1) and 1% (at L2) during less intense storms. Also, depending on the intensity of the storm time ionospheric disturbances, the total number of total electron content (TEC) slips can exceed from 4 to 40 times the quiet time level. Both GPS LoL and TEC slips occur during abrupt changes of SYM-H index of geomagnetic activity, i.e., during the main phase of geomagnetic storms and during development of ionospheric storms. The main contribution in the total number of GPS LoL was found to be done by GPS sites located at low and high latitudes, whereas the area of numerous TEC slips seemed to mostly correspond to the boundary of the auroral oval, i.e., region with intensive ionospheric irregularities. Our global maps of TEC slips show where the regions with intense irregularities of electron density occur during geomagnetic storms and will let us in future predict appearance of GPS errors for geomagnetically disturbed conditions.

  4. The effects of storms and storm-generated currents on sand beaches in Southern Maine, USA

    Science.gov (United States)

    Hill, H.W.; Kelley, J.T.; Belknap, D.F.; Dickson, S.M.

    2004-01-01

    Storms are one of the most important controls on the cycle of erosion and accretion on beaches. Current meters placed in shoreface locations of Saco Bay and Wells Embayment, ME, recorded bottom currents during the winter months of 2000 and 2001, while teams of volunteers profiled the topography of nearby beaches. Coupling offshore meteorological and beach profile data made it possible to determine the response of nine beaches in southern Maine to various oceanographic and meteorological conditions. The beaches selected for profiling ranged from pristine to completely developed and permitted further examination of the role of seawalls on the response of beaches to storms. Current meters documented three unique types of storms: frontal passages, southwest storms, and northeast storms. In general, the current meter results indicate that frontal passages and southwest storms were responsible for bringing sediment towards the shore, while northeast storms resulted in a net movement of sediment away from the beach. During the 1999-2000 winter, there were a greater percentage of frontal passages and southwest storms, while during the 2000-2001 winter, there were more northeast storms. The sediment that was transported landward during the 1999-2000 winter was reworked into the berm along moderately and highly developed beaches during the next summer. A northeast storm on March 5-6, 2001, resulted in currents in excess of 1 m s-1 and wave heights that reached six meters. The storm persisted over 10 high tides and caused coastal flooding and property damage. Topographic profiles made before and after the storm demonstrate that developed beaches experienced a loss of sediment volume during the storm, while sediment was redistributed along the profile on moderately developed and undeveloped beaches. Two months after the storm, the profiles along the developed beaches had not reached their pre-storm elevation. In comparison, the moderately developed and undeveloped beaches

  5. Growth kinetics of hydrogen sulfide oxidizing bacteria in corroded concrete from sewers

    International Nuclear Information System (INIS)

    Jensen, Henriette Stokbro; Lens, Piet N.L.; Nielsen, Jeppe L.; Bester, Kai; Nielsen, Asbjorn Haaning; Hvitved-Jacobsen, Thorkild; Vollertsen, Jes

    2011-01-01

    Hydrogen sulfide oxidation by microbes present on concrete surfaces of sewer pipes is a key process in sewer corrosion. The growth of aerobic sulfur oxidizing bacteria from corroded concrete surfaces was studied in a batch reactor. Samples of corrosion products, containing sulfur oxidizing bacteria, were suspended in aqueous solution at pH similar to that of corroded concrete. Hydrogen sulfide was supplied to the reactor to provide the source of reduced sulfur. The removal of hydrogen sulfide and oxygen was monitored. The utilization rates of both hydrogen sulfide and oxygen suggested exponential bacterial growth with median growth rates of 1.25 d -1 and 1.33 d -1 as determined from the utilization rates of hydrogen sulfide and oxygen, respectively. Elemental sulfur was found to be the immediate product of the hydrogen sulfide oxidation. When exponential growth had been achieved, the addition of hydrogen sulfide was terminated leading to elemental sulfur oxidation. The ratio of consumed sulfur to consumed oxygen suggested that sulfuric acid was the ultimate oxidation product. To the knowledge of the authors, this is the first study to determine the growth rate of bacteria involved in concrete corrosion with hydrogen sulfide as source of reduced sulfur.

  6. Coupled 1D-2D hydrodynamic inundation model for sewer overflow: Influence of modeling parameters

    Directory of Open Access Journals (Sweden)

    Adeniyi Ganiyu Adeogun

    2015-10-01

    Full Text Available This paper presents outcome of our investigation on the influence of modeling parameters on 1D-2D hydrodynamic inundation model for sewer overflow, developed through coupling of an existing 1D sewer network model (SWMM and 2D inundation model (BREZO. The 1D-2D hydrodynamic model was developed for the purpose of examining flood incidence due to surcharged water on overland surface. The investigation was carried out by performing sensitivity analysis on the developed model. For the sensitivity analysis, modeling parameters, such as mesh resolution Digital Elevation Model (DEM resolution and roughness were considered. The outcome of the study shows the model is sensitive to changes in these parameters. The performance of the model is significantly influenced, by the Manning's friction value, the DEM resolution and the area of the triangular mesh. Also, changes in the aforementioned modeling parameters influence the Flood characteristics, such as the inundation extent, the flow depth and the velocity across the model domain. Keywords: Inundation, DEM, Sensitivity analysis, Model coupling, Flooding

  7. Monitoring of carbamazepine concentrations in wastewater and groundwater to quantify sewer leakage.

    Science.gov (United States)

    Fenz, R; Blaschke, A P; Clara, M; Kroiss, H; Mascher, D; Zessner, M

    2005-01-01

    Monitoring of carbamazepine concentrations in wastewater and groundwater enables us to identify and quantify sewer exfiltration. The antiepileptic drug carbamazepine is hardly removed in wastewater treatment plants and not or just slightly attenuated during bank infiltration and subsoil flow. Concentrations in wastewater are generally 1000 times higher than the limit of quantification. In contrast to . many other wastewater tracers carbamazepine is discharged to the environment only via domestic wastewater. The results from this study carried out in Linz, Austria indicate an average exfiltration rate of 1%, expressed as percentage of the dry weather flow that is lost to the groundwater on the city-wide scale. This rate is lower than sewage losses reported in most other studies which attempted to quantify exfiltration on the basis of groundwater pollution. However, it was also possible to identify one area with significantly higher sewage losses. This method seems to be very suitable for the verification of leakage models used to assess sewer exfiltration on a regional scale.

  8. Sewer infiltration/inflow: long-term monitoring based on diurnal variation of pollutant mass flux.

    Science.gov (United States)

    Bares, V; Stránský, D; Sýkora, P

    2009-01-01

    The paper deals with a method for quantification of infiltrating groundwater based on the variation of diurnal pollutant load and continuous water quality and quantity monitoring. Although the method gives us the potential to separate particular components of wastewater hygrograph, several aspects of the method should be discussed. Therefore, the paper investigates the cost-effectiveness, the relevance of pollutant load from surface waters (groundwater) and the influence of measurement time step. These aspects were studied in an experimental catchment of Prague sewer system, Czech Republic, within a three-month period. The results indicate high contribution of parasitic waters on night minimal discharge. Taking into account the uncertainty of the results and time-consuming maintenance of the sensor, the principal advantages of the method are evaluated. The study introduces a promising potential of the discussed measuring concept for quantification of groundwater infiltrating into the sewer system. It is shown that the conventional approach is sufficient and cost-effective even in those catchments, where significant contribution of foul sewage in night minima would have been assumed.

  9. Toxicity and pollutant impact analysis in an urban river due to combined sewer overflows loads.

    Science.gov (United States)

    Casadio, A; Maglionico, M; Bolognesi, A; Artina, S

    2010-01-01

    The Navile Channel (Bologna, Italy) is an ancient artificial water course derived from the Reno river. It is the main receiving water body for the urban catchment of Bologna sewer systems and also for the Waste Water Treatment Plant (WWTP) main outlet. The aim of this work is to evaluate the Combined Sewer Overflows (CSOs) impact on Navile Channel's water quality. In order to collect Navile flow and water quality data in both dry and wet weather conditions, two measuring and sampling stations were installed, right upstream and downstream the WWTP outflow. The study shows that even in case of low intensity rain events, CSOs have a significant effect on both water quantity and quality, spilling a considerable amount of pollutants into the Navile Channel and presenting also acute toxicity effects. The collected data shown a good correlations between the concentrations of TSS and of chemical compounds analyzed, suggesting that the most part of such substances is attached to suspended solids. Resulting toxicity values are fairly high in both measuring points and seem to confirm synergistic interactions between heavy metals.

  10. Dynamics of pollutant discharge in combined sewer systems during rain events: chance or determinism?

    Science.gov (United States)

    Hannouche, A; Chebbo, G; Joannis, C

    2014-01-01

    A large database of continuous flow and turbidity measurements cumulating data on hundreds of rain events and dry weather days from two sites in Paris (called Quais and Clichy) and one in Lyon (called Ecully) is presented. This database is used to characterize and compare the behaviour of the three sites at the inter-events scale. The analysis is probed through three various variables: total volumes and total suspended solids (TSS) masses and concentrations during both wet and dry weather periods in addition to the contributions of diverse-origin sources to event flow volume and TSS load values. The results obtained confirm the previous findings regarding the spatial consistency of TSS fluxes and concentrations between both sites in Paris having similar land uses. Moreover, masses and concentrations are proven to be correlated between Parisian sites in a way that implies the possibility of some deterministic processes being reproducible from one catchment to another for a particular rain event. The results also demonstrate the importance of the contribution of wastewater and sewer deposits to the total events' loads and show that such contributions are not specific to Paris sewer networks.

  11. Combined sewer overflow control with LID based on SWMM: an example in Shanghai, China.

    Science.gov (United States)

    Liao, Z L; Zhang, G Q; Wu, Z H; He, Y; Chen, H

    2015-01-01

    Although low impact development (LID) has been commonly applied across the developed countries for mitigating the negative impacts of combined sewer overflows (CSOs) on urban hydrological environment, it has not been widely used in developing countries yet. In this paper, a typical combined sewer system in an urbanized area of Shanghai, China was used to demonstrate how to design and choose CSO control solutions with LID using stormwater management model. We constructed and simulated three types of CSO control scenarios. Our findings support the notion that LID measures possess favorable capability on CSO reduction. Nevertheless, the green scenarios which are completely comprised by LID measures fail to achieve the maximal effectiveness on CSO reduction, while the gray-green scenarios (LID measure combined with gray measures) achieve it. The unit cost-effectiveness of each type of scenario sorts as: green scenario > gray-green scenario > gray scenario. Actually, as the storage tank is built in the case catchment, a complete application of green scenario is inaccessible here. Through comprehensive evaluation and comparison, the gray-green scenario F which used the combination of storage tank, bio-retention and rain barrels is considered as the most feasible one in this case.

  12. Impact of Combined Sewer Overflow on Wastewater Treatment and Microbiological Quality of Rivers for Recreation

    Directory of Open Access Journals (Sweden)

    Franz Mascher

    2017-11-01

    Full Text Available Within the framework of a one-year study the treatment capacity of a municipal wastewater treatment plant (WWTP was evaluated, with regard to fecal indicator bacteria (FIB and to their influence on the recipient. The logarithmic reduction rates for fecal coliforms (FC, Escherichia coli (EC and intestinal enterococci (IE were 2.84, 2.90 and 2.93. In the investigated period of time, the tested treatment plant released 4.3% of the total annual load flow volume as combined sewer overflow (CSO, that is, when the influent into the combined sewer exceeds the capacity of the treatment plant and coarsely cleaned wastewater arrives at the recipient. This CSO discharge increased the number of FIB significantly by 1.2 × 102 MPN/100 mL for EC, and by 1.8 × 101 MPN/100 mL for IE. For the Styrian part of the Mur River (1.6 million inhabitants, a calculation of FIB of all sewage treatment plants estimating the same ratio of CSO (4.3% and a given mean flow rate (QM results in a significant increase of the FIB load in the recipient: 3.8 × 103 MPN/100 mL for EC and 5.8 × 102 MPN/100 mL for IE. On the basis of these values the standards of water quality for recreational purposes cannot be met.

  13. Ice Storms in a Changing Climate

    Science.gov (United States)

    2016-06-01

    CHANGING CLIMATE by Jennifer M. McNitt June 2016 Thesis Advisor: Wendell Nuss Co-Advisor: David W. Titley THIS PAGE INTENTIONALLY LEFT...SUBTITLE ICE STORMS IN A CHANGING CLIMATE 5. FUNDING NUMBERS 6. AUTHOR(S) Jennifer M. McNitt 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS...increase in global temperatures, due to climate change, could affect the frequency, intensity, and geographic location of ice storms. Three known ice

  14. The effects of sewer infrastructure on water quality: implications for land use studies.

    Science.gov (United States)

    Vrebos, Dirk; Staes, Jan; Meire, Patrick

    2010-05-01

    The European Water Framework Directive requires a good ecological status of the European water bodies and the necessary measures to obtain this have to be implemented. The water quality of a river is the result of complex anthropogenic systems (buildings, waste water treatment infrastructure, regulations, etc.) and biogeochemical and eco-hydrological interactions. It is therefore essential to obtain more insight in the factors that determine the water quality in a river. Research into the relation between land use and water quality is necessary. Human activities have a huge impact on the flow regimes and associated water quality of river systems. Effects of land use bound activities on water quality are often investigated, but these studies generally ignore the hydrological complexity of a human influenced catchment. Infrastructure like sewer systems and wastewater treatment plants (WWTP) can displace huge quantities of polluted water. The transfers change flow paths, displace water between catchments and change the residence time of the system. If we want to correctly understand the effect of land use distribution on water quality we have to take these sewer systems into account. In this study we analyse the relation between land use and water quality in the Nete catchment (Belgium) and investigate the impact of the sewage infrastructure on this relation. The Nete catchment (1.673 km²) is a mosaic of semi natural, agricultural and urbanized areas and the land use is very fragmented. For the moment 74% of the households within the catchment are connected to a WWTP. The discharges from these WWTP's compose 15% of the total discharge of the Nete. Based on a runoff model the surface of upstream land use was calculated for 378 points. These data were then corrected for the impact of WWTP's. Using sewage infrastructure plans, urban areas connected to a WWTP were added to the upstream land use of the WWTP's water receiving stream. In order to understand the effect of

  15. An experiment to use medical I-131 as tracer in a city sewer system

    Energy Technology Data Exchange (ETDEWEB)

    Ulbrich, Susanne; Fischer, Helmut W. [University of Bremen, Institute of Environmental Physics, Otto-Hahn-Allee 1, D-28359 Bremen (Germany)

    2014-07-01

    City sewer systems have to reliably carry residential and industrial wastewater to treatment plants, often mixed with rainwater. Transport in the sewer system is regularly modelled in order to predict sewerage levels, transport velocities and volume discharges. Radioisotopes would be interesting tracers, as they can be detected quickly and without the need of applying wet chemistry. Medical isotopes are released in large quantities (many MBq) by excretion from patients either at the location of administration or from elsewhere, most probably the patient's home. Depending on diagnostic or treatment modality, isotopes of different physical characteristics are used, often bound to compounds of specific metabolic behaviour. Routine environmental surveillance regularly detects the most common diagnostic ({sup 99m}Tc) and therapeutic ({sup 131}I) isotopes in city wastewater samples. Except for {sup 131}I in the case of a nuclear emergency, no contributions from sources other than medical are expected. Medical isotopes therefore might be used for tracing purposes, provided individual inputs can be identified and separated. A field experiment has been designed involving {sup 131}I releases from a single patient who had undergone radioiodine thyroid ablation therapy. This modality is applied after thyroid cancer surgery in order to destroy residual thyroid tissue. Activities up to 5 GBq of {sup 131}I are used which are excreted within few days, as no iodine-retaining thyroid tissue remains. In Germany, about 20,000 of these treatments are performed yearly. For a sewer system of 500,000 inhabitants, about 150 cases would be expected per year, making it quite improbable to have interference between individual patient releases in the same region of the city sewer system. Practically, the radiometric laboratory was informed of the expected release of an (anonymous) patient from the collaborating radiotherapy unit several days in advance, plus the approximate location of

  16. Cesium and strontium behaviors in wastewater collected by different sewer systems

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, Nao K.; Hatanaka, Takuma; Umita, Teruyuki [Department of Civil and Environmental Engineering, Iwate University, 020-8551, Ueda 4-3-5, Morioka, Iwate (Japan); Ito, Ayumi [Department of Frontier Materials and Function Engineering, Graduate School of Engineering Iwate University, 020-8551, Ueda 4-3-5, Morioka, Iwate (Japan)

    2014-07-01

    The nuclear accident at the Fukushima Daiichi Nuclear Power Plant resulted in the release of radionuclides such as {sup 134}Cs, {sup 137}Cs, and {sup 90}Sr into the environment. Some of these radionuclides have been entering sewage treatment plants through sewer systems and then being transferred to sewage sludge. There are two types of sewer systems, e.g. a combined sewer system (CSS) and a separated sewer system (SSS). The CSS transfers rainwater runoff and domestic wastewater to the treatment plants in a single pipe. The SSS has independent pipes; one pipe transfers domestic wastewater to the treatment plant and the other pipe transfers rainwater runoff to river or sea. Since most of the radionuclides released into the atmosphere by the nuclear accident fell onto the land surface by precipitation, the CSS should collect more radionuclides than the SSS. However, there is little information about behavior differences of radionuclides in wastewater between the two types of sewer systems. The objective of the present study was to clarify the differences of radionuclide behavior in wastewater between the CSS and SSS. Behaviors of stable Cs and Sr in wastewater were observed as a means to predict radiocesium and radiostrontium. Two types of wastewater were collected in Morioka city, Japan: wastewater in a CSS in a rain event (WC) and wastewater in a SSS (WS). The WC was taken at a high rate filtration plant every 20 minutes from the beginning of the rain event for several hours in 2013. The WS was collected at a sewage treatment plant once a month from June to October 2013; sometimes the collection was at the time of a rain event. Suspended solid (SS) in each sample was measured as a physicochemical property. The element concentrations in total, dissolved, and particulate fractions were determined. While the SS in the WS taken on rainy day was 0.11 g/L, the SS in the WC was 0.36 g/L in the beginning of the rainfall and then decreased with time. Total Cs concentration

  17. Mapping Hurricane Rita inland storm tide

    Science.gov (United States)

    Berenbrock, Charles; Mason, Jr., Robert R.; Blanchard, Stephen F.; Simonovic, Slobodan P.

    2009-01-01

    Flood-inundation data are most useful for decision makers when presented in the context of maps of effected communities and (or) areas. But because the data are scarce and rarely cover the full extent of the flooding, interpolation and extrapolation of the information are needed. Many geographic information systems (GIS) provide various interpolation tools, but these tools often ignore the effects of the topographic and hydraulic features that influence flooding. A barrier mapping method was developed to improve maps of storm tide produced by Hurricane Rita. Maps were developed for the maximum storm tide and at 3-hour intervals from midnight (0000 hour) through noon (1200 hour) on September 24, 2005. The improved maps depict storm-tide elevations and the extent of flooding. The extent of storm-tide inundation from the improved maximum storm-tide map was compared to the extent of flood-inundation from a map prepared by the Federal Emergency Management Agency (FEMA). The boundaries from these two maps generally compared quite well especially along the Calcasieu River. Also a cross-section profile that parallels the Louisiana coast was developed from the maximum storm-tide map and included FEMA high-water marks.

  18. Thyroid Storm: A Japanese Perspective.

    Science.gov (United States)

    Akamizu, Takashi

    2018-01-01

    Thyroid storm (TS) is life threatening. In the mid-2000s, its incidence was poorly defined, peer-reviewed diagnostic criteria were not available, and management and treatment did not seem to be verified based upon evidence and latest advances in medicine. First, diagnostic criteria were developed based on 99 patients in the literature and seven patients in this study. Then, initial and follow-up surveys were conducted from 2004 through 2008, targeting all hospitals in Japan to obtain and verify information on patients who met diagnostic criteria for TS. Based on these data, the diagnostic criteria were revised, and management and treatment guidelines were created. The incidence of TS in hospitalized patients in Japan was estimated to be 0.20 per 100,000 per year and 0.22% of all thyrotoxic patients. The mortality rate was 10.7%. Multiple organ failure was the most common cause of death, followed by congestive heart failure, respiratory failure, and arrhythmia. In the final diagnostic criteria for TS, the definition of jaundice as serum bilirubin concentration >3 mg/dL was added. Based upon nationwide surveys and the latest information, guidelines for the management and treatment for TS were extensively revised and algorithms were developed. TS remains a life-threatening disorder, with >10% mortality in Japan. New peer-reviewed diagnostic criteria for TS are presented and its clinical features, prognosis, and incidence are clarified based on nationwide surveys. Furthermore, this information helped to establish detailed guidelines for the management and treatment of TS. A prospective prognostic study to validate the guidelines is eagerly anticipated.

  19. Fate of cocaine drug biomarkers in sewer system: the role of suspended solids in biotransformation and sorption

    DEFF Research Database (Denmark)

    Ramin, Pedram; Brock, Andreas Libonati; Polesel, Fabio

    on the fate of illicit drugs in sewer systems. This study aims at assessing the role of suspended solids on the biotransformation and sorption in raw sewage of eight illicit drug biomarkers (cocaine, heroin, methadone, mephedrone, ketamine, methamphetamine, MDMA and THC and their urinary metabolites...

  20. Sediment transport modeling in deposited bed sewers: unified form of May's equations using the particle swarm optimization algorithm.

    Science.gov (United States)

    Safari, Mir Jafar Sadegh; Shirzad, Akbar; Mohammadi, Mirali

    2017-08-01

    May proposed two dimensionless parameters of transport (η) and mobility (F s ) for self-cleansing design of sewers with deposited bed condition. The relationships between those two parameters were introduced in conditional form for specific ranges of F s , which makes it difficult to use as a practical tool for sewer design. In this study, using the same experimental data used by May and employing the particle swarm optimization algorithm, a unified equation is recommended based on η and F s . The developed model is compared with original May relationships as well as corresponding models available in the literature. A large amount of data taken from the literature is used for the models' evaluation. The results demonstrate that the developed model in this study is superior to May and other existing models in the literature. Due to the fact that in May's dimensionless parameters more effective variables in the sediment transport process in sewers with deposited bed condition are considered, it is concluded that the revised May equation proposed in this study is a reliable model for sewer design.

  1. Correlations between reinfall data and insurance damage data related to sewer flooding for the case of Aarhus, Denmark

    NARCIS (Netherlands)

    Spekkers, M.H.; Zhou, Q.; Arnbjerg-Nielsen, K.; Clemens, F.H.L.R.; ten Veldhuis, J.A.E.

    2013-01-01

    Sewer flooding due to extreme rainfall may result in considerable damage. Damage data to quantify costs of cleaning, drying, and replacing materials and goods are rare in literature. In this study, insurance claim data related to property damages were analysed for the municipality of Aarhus,

  2. Geochemical distribution and mobility of heavy metals in sediments of urban streams affected by combined sewer overflows

    Czech Academy of Sciences Publication Activity Database

    Hnaťuková, Petra

    2011-01-01

    Roč. 59, č. 2 (2011), s. 85-94 ISSN 0042-790X R&D Projects: GA AV ČR IAA200600902 Institutional research plan: CEZ:AV0Z20600510 Keywords : sediments * heavy metals * urban streams * sequential extraction * combined sewer overflows Subject RIV: BK - Fluid Dynamics Impact factor: 0.340, year: 2011

  3. Storm water detention tanks in Barcelona; Los depositos de retencion de aguas pluviales de Barcelona: un nuevo enfoque en la lucha contra las inundaciones y la proteccion medioambiental

    Energy Technology Data Exchange (ETDEWEB)

    Pere Malgrat i Bregolat, P.; Verdejo, J. M.; Vilalta i Cambra, A.

    2004-07-01

    Storm water detention tanks are being implemented at first as a solution to the urban flooding problem and afterwards a second function was added to reduce the pollution of the sewerage waters before its overflow to the receiving bodies because these spills can contribute with up to 50% of the total pollution spilled. These solutions are often cheaper and have less impact on the urban activities than the classical solutions such as trunk sewers. In Spain, Barcelona was the first city to build this tanks to avoid flooding and also to reduce the contamination to the receiving waters, with a total volume of 492.200 m''3, operated by Clavegueram de Barcelona (Clabsa). These works have meant a big improvement in the management of the wet weather flows in Barcelona. These tanks have increased the capacity of the sewerage system and decreased the combined sewer overflows to the receiving waters (Besos river and Mediterranean sea). Another advantage is the protection of WWTP against flow variations. The environmental improvement achieved with the tanks is so hug that can even reduce the contamination spilled to the receiving waters around 30% and avoid the destruction of some ecosystems. Also, the contaminated sediments trapped in the detention tank are sen to to the WWTP so the don't reach the receiving waters. Also. the urban space close to the relieving waters are becoming more appreciated for leisure so the recovery and protection of these waters is a must. (Author)

  4. Analysis of Storm Surge in Hong Kong

    Science.gov (United States)

    Kao, W. H.

    2017-12-01

    A storm surge is a type of coastal flood that is caused by low-pressure systems such as tropical cyclones. Storm surges caused by tropical cyclones can be very powerful and damaging, as they can flood coastal areas, and even destroy infrastructure in serious cases. Some serious cases of storm surges leading to more than thousands of deaths include Hurricane Katrina (2005) in New Orleans and Typhoon Haiyan (2013) in Philippines. Hong Kong is a coastal city that is prone to tropical cyclones, having an average of 5-6 tropical cyclones entering 500km range of Hong Kong per year. Storm surges have seriously damaged Hong Kong in the past, causing more than 100 deaths by Typhoon Wanda (1962), and leading to serious damage to Tai O and Cheung Chau by Typhoon Hagupit (2008). To prevent economic damage and casualties from storm surges, accurately predicting the height of storm surges and giving timely warnings to citizens is very important. In this project, I will be analyzing how different factors affect the height of storm surge, mainly using data from Hong Kong. These factors include the windspeed in Hong Kong, the atmospheric pressure in Hong Kong, the moon phase, the wind direction, the intensity of the tropical cyclone, distance between the tropical cyclone and Hong Kong, the direction of the tropical cyclone relative to Hong Kong, the speed of movement of the tropical cyclone and more. My findings will also be compared with cases from other places, to see if my findings also apply for other places.

  5. The StoRM Certification Process

    International Nuclear Information System (INIS)

    Ronchieri, Elisabetta; Dibenedetto, Michele; Zappi, Riccardo; Dal Pra, Stefano; Aiftimiei, Cristina; Traldi, Sergio

    2011-01-01

    StoRM is an implementation of the SRM interface version 2.2 used by all Large Hadron Collider (LHC) experiments and non-LHC experiments as SRM endpoint at different Tiers of Worldwide LHC Computing Grid. The complexity of its services and the demand of experiments and users are increasing day by day. The growing needs in terms of service level by the StoRM users communities make it necessary to design and implement a more effective testing procedure to quickly and reliably validate new StoRM candidate releases both in code side (for example via test units, and schema valuator) and in final product software (for example via functionality tests, and stress tests). Testing software service is a very critical quality activity performed in a very ad-hoc informal manner by developers, testers and users of StoRM up to now. In this paper, we describe the certification mechanism used by StoRM team to increase the robustness and reliability of the StoRM services. Various typologies of tests, such as quality, installation, configuration, functionality, stress and performance, defined on the base of a set of use cases gathered as consequence of the collaboration among the StoRM team, experiments and users, are illustrated. Each typology of test is either increased or decreased easily from time to time. The proposed mechanism is based on a new configurable testsuite. This is executed by the certification team, who is responsible for validating the release candidate package as well as bug fix (or patch) package, given a certain testbed that considers all possible use cases. In correspondence of each failure, the package is given back to developers waiting for validating a new package.

  6. Coastal Storm Surge Analysis: Storm Surge Results. Report 5: Intermediate Submission No. 3

    Science.gov (United States)

    2013-11-01

    Vickery, P., D. Wadhera, A. Cox, V. Cardone , J. Hanson, and B. Blanton. 2012. Coastal storm surge analysis: Storm forcing (Intermediate Submission No...CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Jeffrey L. Hanson, Michael F. Forte, Brian Blanton

  7. Green-blue water in the city: quantification of impact of source control versus end-of-pipe solutions on sewer and river floods.

    Science.gov (United States)

    De Vleeschauwer, K; Weustenraad, J; Nolf, C; Wolfs, V; De Meulder, B; Shannon, K; Willems, P

    2014-01-01

    Urbanization and climate change trends put strong pressures on urban water systems. Temporal variations in rainfall, runoff and water availability increase, and need to be compensated for by innovative adaptation strategies. One of these is stormwater retention and infiltration in open and/or green spaces in the city (blue-green water integration). This study evaluated the efficiency of three adaptation strategies for the city of Turnhout in Belgium, namely source control as a result of blue-green water integration, retention basins located downstream of the stormwater sewers, and end-of-pipe solutions based on river flood control reservoirs. The efficiency of these options is quantified by the reduction in sewer and river flood frequencies and volumes, and sewer overflow volumes. This is done by means of long-term simulations (100-year rainfall simulations) using an integrated conceptual sewer-river model calibrated to full hydrodynamic sewer and river models. Results show that combining open, green zones in the city with stormwater retention and infiltration for only 1% of the total city runoff area would lead to a 30 to 50% reduction in sewer flood volumes for return periods in the range 10-100 years. This is due to the additional surface storage and infiltration and consequent reduction in urban runoff. However, the impact of this source control option on downstream river floods is limited. Stormwater retention downstream of the sewer system gives a strong reduction in peak discharges to the receiving river. However due to the difference in response time between the sewer and river systems, this does not lead to a strong reduction in river flood frequency. The paper shows the importance of improving the interface between urban design and water management, and between sewer and river flood management.

  8. Water System Adaptation to Hydrological Changes: Module 2, Stormwater Management and Sewer Performance under Intense Storms: Case Study from Lawrence, Massachusetts, U.S.A.

    Science.gov (United States)

    This course focuses on water system adaptation to short-term and long-term climate and hydrologic stressors that affect water availability, water quality, security, and resilience. The course is organized into 15 sequential modules. The lectures will be augmented by weekly assign...

  9. Dynamic gauge adjustment of high-resolution X-band radar data for convective rain storms: Model-based evaluation against measured combined sewer overflow

    DEFF Research Database (Denmark)

    Borup, Morten; Grum, Morten; Linde, Jens Jørgen

    2016-01-01

    estimates through a hydraulic urban drainage model. The model is built entirely from physical data, without any calibration, to avoid bias towards any specific type of rainfall estimate. The performance is assessed by comparing measured and modelled water levels at a weir downstream of a highly impermeable......Numerous studies have shown that radar rainfall estimates need to be adjusted against rain gauge measurements in order to be useful for hydrological modelling. In the current study we investigate if adjustment can improve radar rainfall estimates to the point where they can be used for modelling...... overflows from urban drainage systems, and we furthermore investigate the importance of the aggregation period of the adjustment scheme. This is done by continuously adjusting X-band radar data based on the previous 5–30 min of rain data recorded by multiple rain gauges and propagating the rainfall...

  10. Dynamic gauge adjustment of high-resolution X-band radar data for convective rain storms: Model-based evaluation against measured combined sewer overflow

    Science.gov (United States)

    Borup, Morten; Grum, Morten; Linde, Jens Jørgen; Mikkelsen, Peter Steen

    2016-08-01

    Numerous studies have shown that radar rainfall estimates need to be adjusted against rain gauge measurements in order to be useful for hydrological modelling. In the current study we investigate if adjustment can improve radar rainfall estimates to the point where they can be used for modelling overflows from urban drainage systems, and we furthermore investigate the importance of the aggregation period of the adjustment scheme. This is done by continuously adjusting X-band radar data based on the previous 5-30 min of rain data recorded by multiple rain gauges and propagating the rainfall estimates through a hydraulic urban drainage model. The model is built entirely from physical data, without any calibration, to avoid bias towards any specific type of rainfall estimate. The performance is assessed by comparing measured and modelled water levels at a weir downstream of a highly impermeable, well defined, 64 ha urban catchment, for nine overflow generating rain events. The dynamically adjusted radar data perform best when the aggregation period is as small as 10-20 min, in which case it performs much better than static adjusted radar data and data from rain gauges situated 2-3 km away.

  11. Flood reduction as an ecosystem service of constructed wetlands for combined sewer overflow

    Science.gov (United States)

    Rizzo, A.; Bresciani, R.; Masi, F.; Boano, F.; Revelli, R.; Ridolfi, L.

    2018-05-01

    Urban runoff negatively impacts the receiving streams and different solutions have been proposed in literature to limit the effect of urbanization on the water balance. These solutions suggest to manage urban runoff in order to switch from a post-development river hydrograph (high peak and short duration) back again to a pre-development hydrograph (low peak and high duration). Combined sewer overflows (CSOs) represent severe pollutant sources for receiving streams due to the combination of first flush of roads and sewers and black water conveyed by combined sewer systems. Constructed wetlands for CSO treatment (CSO-CWs) are adopted with increasing frequency for reducing pollutant inputs to streams. Moreover, these systems exhibit the characteristic to behave similarly to ponds, wetlands, and bioretention systems that provide flood mitigation by decreasing the intensity of peak flows. This work aims to show the additional ecosystem service provided by CSO-CWs in term of limitation of the hydraulic impact of CSO on stream hydrograph. A mathematical model is developed to simulate the hydraulic behavior of a real case study situated in Gorla Maggiore (Italy), which includes vertical flow subsurface beds (VF) as first stage and a free water surface bed (FWS) as second stage. The model simulates the unsaturated flow within VF and the accumulation of water on the top of VF and within FWS. Results show a satisfactory lamination performance of the system for both single and up to 5 consecutive flood events, with a peak flow reduction ranging from 52.7% to 95.4%. Withdrawn of flow rate from the river in order to cope with long dry period does not significantly affect the lamination performances. The considered CSO-CW exhibits an excellent lamination efficiency also during more intense floods events, with a peak flow reduction of 86.2% for a CSO event with return period of 10 years. The flow rate frequency density function determined by the CSO-CW is more shifted towards

  12. Healthcare4VideoStorm: Making Smart Decisions Based on Storm Metrics.

    Science.gov (United States)

    Zhang, Weishan; Duan, Pengcheng; Chen, Xiufeng; Lu, Qinghua

    2016-04-23

    Storm-based stream processing is widely used for real-time large-scale distributed processing. Knowing the run-time status and ensuring performance is critical to providing expected dependability for some applications, e.g., continuous video processing for security surveillance. The existing scheduling strategies' granularity is too coarse to have good performance, and mainly considers network resources without computing resources while scheduling. In this paper, we propose Healthcare4Storm, a framework that finds Storm insights based on Storm metrics to gain knowledge from the health status of an application, finally ending up with smart scheduling decisions. It takes into account both network and computing resources and conducts scheduling at a fine-grained level using tuples instead of topologies. The comprehensive evaluation shows that the proposed framework has good performance and can improve the dependability of the Storm-based applications.

  13. Examples of storm impacts on barrier islands: Chapter 4

    Science.gov (United States)

    Plant, Nathaniel G.; Doran, Kara; Stockdon, Hilary F.

    2017-01-01

    This chapter focuses on the morphologic variability of barrier islands and on the differences in storm response. It describes different types of barrier island response to individual storms, as well as the integrated response of barrier islands to many storms. The chapter considers case study on the Chandeleur Island chain, where a decadal time series of island elevation measurements have documented a wide range of barrier island responses to storms and long-term processes that are representative of barrier island behaviour at many other locations. These islands are low elevation, extremely vulnerable to storms and exhibit a diversity of storm responses. Additionally, this location experiences a moderately high rate of relative sea-level rise, increasing its vulnerability to the combined impacts of storms and long-term erosional processes. Understanding how natural processes, including storm impacts and intervening recovery periods interact with man-made restoration processes is also broadly relevant to understand the natural and human response to future storms.

  14. Acceleration and loss of relativistic electrons during small geomagnetic storms.

    Science.gov (United States)

    Anderson, B R; Millan, R M; Reeves, G D; Friedel, R H W

    2015-12-16

    Past studies of radiation belt relativistic electrons have favored active storm time periods, while the effects of small geomagnetic storms ( D s t  > -50 nT) have not been statistically characterized. In this timely study, given the current weak solar cycle, we identify 342 small storms from 1989 through 2000 and quantify the corresponding change in relativistic electron flux at geosynchronous orbit. Surprisingly, small storms can be equally as effective as large storms at enhancing and depleting fluxes. Slight differences exist, as small storms are 10% less likely to result in flux enhancement and 10% more likely to result in flux depletion than large storms. Nevertheless, it is clear that neither acceleration nor loss mechanisms scale with storm drivers as would be expected. Small geomagnetic storms play a significant role in radiation belt relativistic electron dynamics and provide opportunities to gain new insights into the complex balance of acceleration and loss processes.

  15. Mathematical modeling of tornadoes and squall storms

    Directory of Open Access Journals (Sweden)

    Sergey A. Arsen’yev

    2011-04-01

    Full Text Available Recent advances in modeling of tornadoes and twisters consist of significant achievements in mathematical calculation of occurrence and evolution of a violent F5-class tornado on the Fujita scale, and four-dimensional mathematical modeling of a tornado with the fourth coordinate time multiplied by its characteristic velocity. Such a tornado can arise in a thunderstorm supercell filled with turbulent whirlwinds. A theory of the squall storms is proposed. The squall storm is modeled by running perturbation of the temperature inversion on the lower boundary of cloudiness. This perturbation is induced by the action of strong, hurricane winds in the upper and middle troposphere, and looks like a running solitary wave (soliton; which is developed also in a field of pressure and velocity of a wind. If a soliton of a squall storm gets into the thunderstorm supercell then this soliton is captured by supercell. It leads to additional pressure fall of air inside a storm supercell and stimulate amplification of wind velocity here. As a result, a cyclostrophic balance inside a storm supercell generates a tornado. Comparison of the radial distribution of wind velocity inside a tornado calculated by using the new formulas and equations with radar observations of the wind velocity inside Texas Tornado Dummit in 1995 and inside the 3 May 1999 Oklahoma City Tornado shows good correspondence.

  16. Factors Associated With Mortality of Thyroid Storm

    Science.gov (United States)

    Ono, Yosuke; Ono, Sachiko; Yasunaga, Hideo; Matsui, Hiroki; Fushimi, Kiyohide; Tanaka, Yuji

    2016-01-01

    Abstract Thyroid storm is a life-threatening and emergent manifestation of thyrotoxicosis. However, predictive features associated with fatal outcomes in this crisis have not been clearly defined because of its rarity. The objective of this study was to investigate the associations of patient characteristics, treatments, and comorbidities with in-hospital mortality. We conducted a retrospective observational study of patients diagnosed with thyroid storm using a national inpatient database in Japan from April 1, 2011 to March 31, 2014. Of approximately 21 million inpatients in the database, we identified 1324 patients diagnosed with thyroid storm. The mean (standard deviation) age was 47 (18) years, and 943 (71.3%) patients were female. The overall in-hospital mortality was 10.1%. The number of patients was highest in the summer season. The most common comorbidity at admission was cardiovascular diseases (46.6%). Multivariable logistic regression analyses showed that higher mortality was significantly associated with older age (≥60 years), central nervous system dysfunction at admission, nonuse of antithyroid drugs and β-blockade, and requirement for mechanical ventilation and therapeutic plasma exchange combined with hemodialysis. The present study identified clinical features associated with mortality of thyroid storm using large-scale data. Physicians should pay special attention to older patients with thyrotoxicosis and coexisting central nervous system dysfunction. Future prospective studies are needed to clarify treatment options that could improve the survival outcomes of thyroid storm. PMID:26886648

  17. The storm time central plasma sheet

    Directory of Open Access Journals (Sweden)

    R. Schödel

    2002-11-01

    Full Text Available The plasma sheet plays a key role during magnetic storms because it is the bottleneck through which large amounts of magnetic flux that have been eroded from the dayside magnetopause have to be returned to the dayside magnetosphere. Using about five years of Geotail data we studied the average properties of the near- and midtail central plasma sheet (CPS in the 10–30 RE range during magnetic storms. The earthward flux transport rate is greatly enhanced during the storm main phase, but shows a significant earthward decrease. Hence, since the magnetic flux cannot be circulated at a sufficient rate, this leads to an average dipolarization of the central plasma sheet. An increase of the specific entropy of the CPS ion population by a factor of about two during the storm main phase provides evidence for nonadiabatic heating processes. The direction of flux transport during the main phase is consistent with the possible formation of a near-Earth neutral line beyond ~20 RE.Key words. Magnetospheric physics (plasma convection; plasma sheet; storms and substorms

  18. Thyrotoxicosis and Choledocholithiasis Masquerading as Thyroid Storm

    Directory of Open Access Journals (Sweden)

    Christian L. Horn

    2017-01-01

    Full Text Available A 26-year-old female, thirteen months postpartum, presented to the emergency department for four weeks of epigastric abdominal pain, pruritus, new onset jaundice, and 11.3 kgs (25 lbs unintentional weight loss. On examination, she was afebrile, tachycardic, alert, and oriented and had jaundice with scleral icterus. Labs were significant for undetectable TSH, FT4 that was too high to measure, and elevated total bilirubin, direct bilirubin, alkaline phosphatase, and transaminases. Abdominal ultrasound revealed cholelithiasis without biliary ductal dilation. Treatment for presumed thyroid storm was initiated. Further work-up with magnetic resonance cholangiopancreatography (MRCP revealed an obstructing cholelith within the distal common bile duct. With the presence of choledocholithiasis explaining the jaundice and abdominal pain, plus the absence of CNS alterations, the diagnosis of thyroid storm was revised to thyrotoxicosis complicated by choledocholithiasis. Endoscopic retrograde cholangiopancreatogram (ERCP with sphincterotomy was performed to alleviate the biliary obstruction, with prompt symptomatic improvement. Thyroid storm is a rare manifestation of hyperthyroidism with a high rate of morbidity and mortality. The diagnosis of thyroid storm is based on clinical examination, and abnormal thyroid function tests do not correlate with disease severity. Knowledge of the many manifestations of thyroid storm will facilitate a quick and accurate diagnosis and treatment.

  19. Combined sewer overflows: an environmental source of hormones and wastewater micropollutants

    Science.gov (United States)

    Phillips, P.J.; Chalmers, A.T.; Gray, J.L.; Kolpin, D.W.; Foreman, W.T.; Wall, G.R.

    2012-01-01

    Data were collected at a wastewater treatment plant (WWTP) in Burlington, Vermont, USA, (serving 30,000 people) to assess the relative contribution of CSO (combined sewer overflow) bypass flows and treated wastewater effluent to the load of steroid hormones and other wastewater micropollutants (WMPs) from a WWTP to a lake. Flow-weighted composite samples were collected over a 13 month period at this WWTP from CSO bypass flows or plant influent flows (n = 28) and treated effluent discharges (n = 22). Although CSO discharges represent 10% of the total annual water discharge (CSO plus treated plant effluent discharges) from the WWTP, CSO discharges contribute 40–90% of the annual load for hormones and WMPs with high (>90%) wastewater treatment removal efficiency. By contrast, compounds with low removal efficiencies (hormones and many WMPs in samples from treated discharges can increase with increasing flow due to decreasing removal efficiency.

  20. Use long short-term memory to enhance Internet of Things for combined sewer overflow monitoring

    Science.gov (United States)

    Zhang, Duo; Lindholm, Geir; Ratnaweera, Harsha

    2018-01-01

    Combined sewer overflow causes severe water pollution, urban flooding and reduced treatment plant efficiency. Understanding the behavior of CSO structures is vital for urban flooding prevention and overflow control. Neural networks have been extensively applied in water resource related fields. In this study, we collect data from an Internet of Things monitoring CSO structure and build different neural network models for simulating and predicting the water level of the CSO structure. Through a comparison of four different neural networks, namely multilayer perceptron (MLP), wavelet neural network (WNN), long short-term memory (LSTM) and gated recurrent unit (GRU), the LSTM and GRU present superior capabilities for multi-step-ahead time series prediction. Furthermore, GRU achieves prediction performances similar to LSTM with a quicker learning curve.

  1. ECO-TECHNIQUE OF SEWER RENOVATION USING COMPOSITE SHELLS: STRUCTURAL ANALYSIS

    Directory of Open Access Journals (Sweden)

    B. Attaf

    2015-07-01

    Full Text Available An eco-technical renovation of the sewage system is developed in this paper; this technique involves incorporating into the existing sewer a series of jointed prefabricated sandwich or composite shells. The purpose of his study is to determine the structural shell deflection, the high displacement areas and to validate the non-failure criterion for each ply constituting the inner and outer laminate facings. The numerical results were obtained at low cost by using the finite element method. Studies have focused on structural analysis of a typical shell unit with an ovoid form (egg-shaped section when it is subjected, during annular space filling operation, to pressure forces generated by wet concrete. To ensure the safety of the composite shell structure, Tsai-Hill criterion function is applied and results are presented for the most stressed plies

  2. [Study on the characteristics of combined sewer overflow from the high density residential area in Shanghai].

    Science.gov (United States)

    Li, He; Li, Tian

    2006-08-01

    The urban non-point pollution has become main pollution resource of urban water bodies of Shanghai. Character of combined sewer overflow from watershed SA in Shanghai was studied, and the correlation of influence factors to the EMCs of overflows was discussed. It is found that the EMCs of COD, BOD, SS, NH3-N, TN, TP are 614 mg/L, 208.5 mg/L, 684 mg/L, 17.6 mg/L, 29.8 mg/L, 3.0 mg/L respectively, and the values obtained herein are much higher than the documented data from other countries. From the probability plot of the EMCs, it is found that the BOD has the best fitness for lognormal distribution; and correlation between the EMCs of COD, SS and the ratio of antecedent dry weather time to rain duration is quite good.

  3. Modeling climate change impacts on combined sewer overflow using synthetic precipitation time series.

    Science.gov (United States)

    Bendel, David; Beck, Ferdinand; Dittmer, Ulrich

    2013-01-01

    In the presented study climate change impacts on combined sewer overflows (CSOs) in Baden-Wuerttemberg, Southern Germany, were assessed based on continuous long-term rainfall-runoff simulations. As input data, synthetic rainfall time series were used. The applied precipitation generator NiedSim-Klima accounts for climate change effects on precipitation patterns. Time series for the past (1961-1990) and future (2041-2050) were generated for various locations. Comparing the simulated CSO activity of both periods we observe significantly higher overflow frequencies for the future. Changes in overflow volume and overflow duration depend on the type of overflow structure. Both values will increase at simple CSO structures that merely divide the flow, whereas they will decrease when the CSO structure is combined with a storage tank. However, there is a wide variation between the results of different precipitation time series (representative for different locations).

  4. Determination of kinetics and stoichiometry of chemical sulfide oxidation in wastewater of sewer networks

    DEFF Research Database (Denmark)

    Nielsen, Asbjørn Haaning; Vollertsen, Jes; Hvitved-Jacobsen, Thorkild

    2003-01-01

    A method for determination of kinetics and stoichiometry of chemical sulfide oxidation by dissolved oxygen (DO) in wastewater is presented. The method was particularly developed to investigate chemical sulfide oxidation in wastewater of sewer networks at low DO concentrations. The method is based...... be considered constant during the course of the experiments although intermediates accumulated. This was explained by an apparent slow oxidation rate of the intermediates. The method was capable of determining kinetics and stoichiometry of chemical sulfide oxidation at DO concentrations lower than 1 g of O2 m...... on continuous measurement of the reactants allowing the kinetics to be determined at varying reactant concentrations during the course of the experiment. The kinetics determined was simulated by a rate equation. The precision of the method was assessed in terms of the standard deviation of the kinetic...

  5. Grey Box Modelling of Flow in Sewer Systems with State Dependent Diffusion

    DEFF Research Database (Denmark)

    Breinholt, Anders; Thordarson, Fannar Örn; Møller, Jan Kloppenborg

    2011-01-01

    . It is shown that an additive diffusion noise term description leads to a violation of the physical constraints of the system, whereas a state dependent diffusion noise avoids this problem and should be favoured. It is also shown that a logarithmic transformation of the flow measurements secures positive lower...... flow prediction limits, because the observation noise is proportionally scaled with the modelled output. Finally it is concluded that a state proportional diffusion term best and adequately describes the one-step flow prediction uncertainty, and a proper description of the system noise is important......Generating flow forecasts with uncertainty limits from rain gauge inputs in sewer systems require simple models with identifiable parameters that can adequately describe the stochastic phenomena of the system. In this paper, a simple grey-box model is proposed that is attractive for both...

  6. Laboratory and field investigation of chemical disinfection of combined sewer overflow in Copenhagen area

    DEFF Research Database (Denmark)

    Chhetri, Ravi Kumar; Thornberg, Dines; Berner, Jesper

    We investigated the possibility to apply performic acid (PFA) and peracetic acid (PAA) for disinfection of combined sewer overflow (CSO) in existing CSO management infrastructures. The disinfection power of PFA and PAA to Escherichia coli (E. coli) and enterococcus were studied in batch scale...... and pre-field experiment. In batch scale experiment 2.5 mg·L -1 PAA removed around 4 log unit of E. coli and enterococcus from CSO with long contact time. Removal of E. coli and enterococcus from CSO were always around or above 3 log unit using 2-4 mg·L -1 PFA with short contact time in batch scale...... and pre-field experiment. There were no toxicological effect measured by Vibrio fischeri when CSO was disinfected with PFA, slight toxicological effect was observed on CSO disinfected with PAA. When the design for PFA based disinfection was applied to CSO collected from an authentic event. Disinfection...

  7. Chemical disinfection of combined sewer overflow waters using performic acid or peracetic acids

    DEFF Research Database (Denmark)

    Chhetri, Ravi Kumar; Thornberg, Dines; Berner, Jesper

    2014-01-01

    We investigated the possibility of applying performic acid (PFA) and peracetic acid (PAA) for disinfection of combined sewer overflow (CSO) in existing CSO management infrastructures. The disinfection power of PFA and PAA towards Escherichia coli (E. coli) and Enterococcus was studied in batch......-scale and pre-field experiments. In the batch-scale experiment, 2.5 mg L− 1 PAA removed approximately 4 log unit of E. coli and Enterococcus from CSO with a 360 min contact time. The removal of E. coli and Enterococcus from CSO was always around or above 3 log units using 2–4 mg L− 1 PFA; with a 20 min contact...... time in both batch-scale and pre-field experiments. There was no toxicological effect measured by Vibrio fischeri when CSO was disinfected with PFA; a slight toxic effect was observed on CSO disinfected with PAA. When the design for PFA based disinfection was applied to CSO collected from an authentic...

  8. Experimental and Numerical Analysis of Egg-Shaped Sewer Pipes Flow Performance

    Directory of Open Access Journals (Sweden)

    Manuel Regueiro-Picallo

    2016-12-01

    Full Text Available A Computational Fluid Dynamics (CFD model was developed to analyze the open-channel flow in a new set of egg-shaped pipes for small combined sewer systems. The egg-shaped cross-section was selected after studying several geometries under different flow conditions. Once the egg-shaped cross-section was defined, a real-scale physical model was built and a series of partial-full flow experiments were performed in order to validate the numerical simulations. Furthermore, the numerical velocity distributions were compared with an experimental formulation for analytic geometries, with comparison results indicating a satisfactory concordance. After the hydraulic performance of the egg-shaped pipe was analyzed, the numerical model was used to compare the average velocity and shear stress against an equivalent area circular pipe under low flow conditions. The proposed egg shape showed a better flow performance up to a filling ratio of h/H = 0.25.

  9. Reconcentration of radioactive material released to sanitary sewers in accordance with 10 CFR Part 20

    International Nuclear Information System (INIS)

    Ainsworth, C.C.; Hill, R.L.; Cantrell, K.J.; Kaplan, D.I.; Norton, M.V.; Aaberg, R.L.; Stetar, E.A.

    1994-12-01

    The US Nuclear Regulatory Commission (NRC), in accordance with 10 CFR 20, and agreement states, in accordance with state regulations, regulates the discharge of radioactive materials into sanitary sewer systems. A one-year study was conducted by Pacific Northwest Laboratory (PNL) for the NRC to assess whether radioactive materials that are dischared to sanitary sewer systems undergo significant reconcentration within the wastewater treatment plants (WWTP) and to determine the physical and/or chemical processes that may result in radionuclide reconcentration within the WWTPs. The study objectives were addressed by collecting information and data on wastewater treatment, relevant geochemical processes, and individual radionuclide behavior in WWTPs from the open literature, NRC reports, EPA surveys, and interviews with NRC licensees and staff of WWTPs that may be impacted by these discharges. Radionuclide mass balance and removal efficiencies were calculated for WWTPs at Oak Ridge, TN; and Erwin, TN, but were not shown to be reliable since the licensee release data generally underestimated the mass of radionuclide that was ultimately found in the sludge. This disparity may be due, in part, to the fact that data available for use in this study were collected to address regulatory concerns and not to perform mass balance calculations. A limited modeling study showed some promise for predicting radionuclide behavior in WWTPS, however, the general applicability of using these empirical models remains uncertain. With the data and models currently available, it is not possible to quantitatively determine the physical and chemical processes that cause reconcentration or to calculate, a priori, reconcentration factors for specific WWTP unit processes or WWTPs in general

  10. Assessing the performance of sewer rehabilitation on the reduction of infiltration and inflow.

    Science.gov (United States)

    Staufer, P; Scheidegger, A; Rieckermann, J

    2012-10-15

    Inflow and Infiltration (I/I) into sewer systems is generally unwanted, because, among other things, it decreases the performance of wastewater treatment plants and increases combined sewage overflows. As sewer rehabilitation to reduce I/I is very expensive, water managers not only need methods to accurately measure I/I, but also they need sound approaches to assess the actual performance of implemented rehabilitation measures. However, such performance assessment is rarely performed. On the one hand, it is challenging to adequately take into account the variability of influential factors, such as hydro-meteorological conditions. On the other hand, it is currently not clear how experimental data can indeed support robust evidence for reduced I/I. In this paper, we therefore statistically assess the performance of rehabilitation measures to reduce I/I. This is possible by using observations in a suitable reference catchment as a control group and assessing the significance of the observed effect by regression analysis, which is well established in other disciplines. We successfully demonstrate the usefulness of the approach in a case study, where rehabilitation reduced groundwater infiltration by 23.9%. A reduction of stormwater inflow of 35.7%, however, was not statistically significant. Investigations into the experimental design of monitoring campaigns confirmed that the variability of the data as well as the number of observations collected before the rehabilitation impact the detection limit of the effect. This implies that it is difficult to improve the data quality after the rehabilitation has been implemented. Therefore, future practical applications should consider a careful experimental design. Further developments could employ more sophisticated monitoring methods, such as stable environmental isotopes, to directly observe the individual infiltration components. In addition, water managers should develop strategies to effectively communicate statistically

  11. Organic micropollutants discharged by combined sewer overflows - Characterisation of pollutant sources and stormwater-related processes.

    Science.gov (United States)

    Launay, Marie A; Dittmer, Ulrich; Steinmetz, Heidrun

    2016-11-01

    To characterise emissions from combined sewer overflows (CSOs) regarding organic micropollutants, a monitoring study was undertaken in an urban catchment in southwest Stuttgart, Germany. The occurrence of 69 organic micropollutants was assessed at one CSO outfall during seven rain events as well as in the sewage network at the influent of the wastewater treatment plant (WWTP) and in the receiving water. Several pollutant groups like pharmaceuticals and personal care products (PPCPs), urban biocides and pesticides, industrial chemicals, organophosphorus flame retardants, plasticisers and polycyclic aromatic hydrocarbons (PAHs) were chosen for analysis. Out of the 69 monitored substances, 60 were detected in CSO discharges. The results of this study show that CSOs represent an important pathway for a wide range of organic micropollutants from wastewater systems to urban receiving waters. For most compounds detected in CSO samples, event mean concentrations varied between the different events in about one order of magnitude range. When comparing CSO concentrations with median wastewater concentrations during dry weather, two main patterns could be observed depending on the source of the pollutant: (i) wastewater is diluted by stormwater; (ii) stormwater is the most important source of a pollutant. Both wastewater and stormwater only play an important role in pollutant concentration for a few compounds. The proportion of stormwater calculated with the conductivity is a suitable indicator for the evaluation of emitted loads of dissolved wastewater pollutants, but not for all compounds. In fact, this study demonstrates that remobilisation of in-sewer deposits contributed from 10% to 65% to emissions of carbamazepine in CSO events. The contribution of stormwater to CSO emitted loads was higher than 90% for all herbicides as well as for PAHs. Regarding the priority substance di(2-ethylhexyl)phthalate (DEHP), this contribution varied between 39% and 85%. The PAH

  12. PPCPs wet weather mobilization in a combined sewer in NW Spain.

    Science.gov (United States)

    Del Río, Héctor; Suárez, Joaquín; Puertas, Jerónimo; Ures, Pablo

    2013-04-01

    An intense campaign was carried out over a 14 month period to characterize concentrations and loads of 7 well-known Pharmaceuticals and Personal Care Products (PPCPs), during dry and wet weather conditions, in an urban combined catchment in the northwest of Spain, a geographical zone with an average annual rainfall over 1500 mm. The main objective was to gather more in-depth knowledge of the mobilization of these "micropollutants" in an urban combined sewer and the possible pressures on water receiving bodies due to combined sewer overflows (CSOs). Hydrographs and pollutographs of these substances in dry weather flows (DWF), on weekdays and weekends, and wet weather flows (WWF) during 10 rain events have been characterized to obtain data that are sufficiently representative for statistical analysis. The research findings show that there is a considerable mobilization of these substances during rain events, mainly in the first part of the hydrographs, especially HHCB galaxolide, ibuprofen and paracetamol with maximum concentrations of 9.76, 8.51 and 5.71 μg/L respectively, whereas these concentrations in dry weather only reached 2.57, 2.11 and 0.72 μg/L respectively. There is a good correlation between the degree of mobilization in wet weather flows and the percentage of dry weather particulate phase of each studied substance, indicating that such mobilization may be associated with adsorption on the sediments deposited on the collectors during the antecedent dry period. These results are in good agreement with removal in conventional WWTP, especially for compounds that tend to adsorb onto sewage sludge. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. VLF Wave Properties During Geomagnetic Storms

    Science.gov (United States)

    Blancarte, J.; Artemyev, A.; Mozer, F.; Agapitov, O. V.

    2017-12-01

    Whistler-mode chorus is important for the global dynamics of the inner magnetosphere electron population due to its ability to scatter and accelerate electrons of a wide energy range in the outer radiation belt. The parameters of these VLF emissions change dynamically during geomagnetic storms. Presented is an analysis of four years of Van Allen probe data, utilizing electric and magnetic field in the VLF range focused on the dynamics of chorus wave properties during the enhancement of geomagnetic activity. It is found that VLF emissions respond to geomagnetic storms in more complicated ways than just by affecting the waves' amplitude growth or depletion. Oblique wave amplitudes grow together with parallel waves during periods of intermediate geomagnetic activity, while the occurrence rate of oblique waves decreases during larger geomagnetic storms.

  14. Thyroid storm precipitated by radioactive iodine therapy

    International Nuclear Information System (INIS)

    Redkar, Neelam N.; Rawat, Kavita J.; Yelale, Abhijit; Shivchand, Akshay

    2015-01-01

    Thyroid storm or thyrotoxic crisis is a rare but life-threatening condition requiring immediate treatment, preferably in an intensive care unit. Its incidence is about 1-2% among patients with overt hyperthyroidism. A thyrotoxic crisis occurs predominantly in the elderly and is three to five times more common in women than in men. The overall mortality is 10-20%. Even though the pathogenesis is still not fully understood, an increased sensitivity to catecholamines appears to be an important mechanism, and a number of endogenous and exogenous stress factors that can provoke the onset of a thyrotoxic storm have been identified. Authors presented a case where the cause of precipitation of thyroid storm was improper preparation of patient for Radioactive iodine treatment

  15. The assessment of Urban Storm Inundation

    Science.gov (United States)

    Setyandito, Oki; Wijayanti, Yureana; Alwan, Muhammad; Chayati, Cholilul; Meilani

    2017-12-01

    A Sustainable and integrated plan in order to solve urban storm inundation problem, is an urgent issue in Indonesia. A reliable and complete datasets of urban storm inundation area in Indonesia should become its basis to give clear description of inundation area for formulating the best solution. In this study, Statistics Indonesia data in thirty three provinces were assessed during 2000 until 2012 providing data series of urban flood area, flood frequency and land cover changes. Drainage system condition in big cities should be well understood to ensure its infrastructure condition and performance. If inundation occurred, it can be concluded that there is drainage system problem. Inundation data is also important for drainage system design process in the future. The study result is provided estimation of urban storm inundation area based on calculation of Statistics Indonesia data. Moreover, this study is preceded by analyzing and reviewing the capacity of existing drainage channel, using case study of Mataram, West Nusa Tenggara. Rainfall data was obtained from three rainfall stations surround Mataram City. The storm water quantity was calculated using three different approaches as follows: 1) Rational Method; 2) Summation of existing inundation and surface run off discharge; 3) Discharge calculation from existing channel dimensions. After that, the result of these approaches was compared. The storm water quantity gap was concluded as quantity of inundation. The result shows that 36% of drainage channel in Brenyok Kanan River sub system could not accommodate the storm water runoff in this area, which causing inundation. The redesign of drainage channel using design discharge from Rational Method approach should be performed. Within area with the lowest level topography, a construction of detention or storage pond is essential to prevent inundation in this area. Furthermore, the benefits and drawbacks of the statistics database are discussed. Recommendations

  16. Zonal wind observations during a geomagnetic storm

    Science.gov (United States)

    Miller, N. J.; Spencer, N. W.

    1986-01-01

    In situ measurements taken by the Wind and Temperature Spectrometer (WATS) onboard the Dynamics Explorer 2 spacecraft during a geomagnetic storm display zonal wind velocities that are reduced in the corotational direction as the storm intensifies. The data were taken within the altitudes 275 to 475 km in the dusk local time sector equatorward of the auroral region. Characteristic variations in the value of the Dst index of horizontal geomagnetic field strength are used to monitor the storm evolution. The detected global rise in atmospheric gas temperature indicates the development of thermospheric heating. Concurrent with that heating, reductions in corotational wind velocities were measured equatorward of the auroral region. Just after the sudden commencement, while thermospheric heating is intense in both hemispheres, eastward wind velocities in the northern hemisphere show reductions ranging from 500 m/s over high latitudes to 30 m/s over the geomagnetic equator. After 10 hours storm time, while northern thermospheric heating is diminishing, wind velocity reductions, distinct from those initially observed, begin to develop over southern latitudes. In the latter case, velocity reductions range from 300 m/s over the highest southern latitudes to 150 m/s over the geomagnetic equator and extend into the Northern Hemisphere. The observations highlight the interhemispheric asymmetry in the development of storm effects detected as enhanced gas temperatures and reduced eastward wind velocities. Zonal wind reductions over high latitudes can be attributed to the storm induced equatorward spread of westward polar cap plasma convection and the resulting plasma-neutral collisions. However, those collisions are less significant over low latitudes; so zonal wind reductions over low latitudes must be attributed to an equatorward extension of a thermospheric circulation pattern disrupted by high latitude collisions between neutrals transported via eastward winds and ions

  17. Adaptive mesh refinement for storm surge

    KAUST Repository

    Mandli, Kyle T.; Dawson, Clint N.

    2014-01-01

    An approach to utilizing adaptive mesh refinement algorithms for storm surge modeling is proposed. Currently numerical models exist that can resolve the details of coastal regions but are often too costly to be run in an ensemble forecasting framework without significant computing resources. The application of adaptive mesh refinement algorithms substantially lowers the computational cost of a storm surge model run while retaining much of the desired coastal resolution. The approach presented is implemented in the GeoClaw framework and compared to ADCIRC for Hurricane Ike along with observed tide gauge data and the computational cost of each model run. © 2014 Elsevier Ltd.

  18. Adaptive mesh refinement for storm surge

    KAUST Repository

    Mandli, Kyle T.

    2014-03-01

    An approach to utilizing adaptive mesh refinement algorithms for storm surge modeling is proposed. Currently numerical models exist that can resolve the details of coastal regions but are often too costly to be run in an ensemble forecasting framework without significant computing resources. The application of adaptive mesh refinement algorithms substantially lowers the computational cost of a storm surge model run while retaining much of the desired coastal resolution. The approach presented is implemented in the GeoClaw framework and compared to ADCIRC for Hurricane Ike along with observed tide gauge data and the computational cost of each model run. © 2014 Elsevier Ltd.

  19. Financial Management: Promptness of FY 2002 Third Quarter DoD Payments to the Department of the Treasury for District of Columbia Water and Sewer Services

    National Research Council Canada - National Science Library

    2002-01-01

    ... the agency's promptness in paying the District of Columbia for water and sewer services. The audit reports must be submitted to the House and Senate Appropriations Committees within 15 days of the start of each quarter...

  20. Promptness of FY 2002 Second Quarter DoD Payments to the US Treasury for District of Columbia Water and Sewer Services

    National Research Council Canada - National Science Library

    2002-01-01

    .... Public Law 106-554 requires the inspector general of each Federal agency that receives water and sewer services from the District of Columbia to report to the Congressional Appropriations Committees...

  1. Uncertainty in return period analysis of combined sewer overflow effects using embedded Monte Carlo simulations

    NARCIS (Netherlands)

    Grum, M.; Aalderink, R.H.

    1999-01-01

    The rerun periods of detrimental effects ate often used as design criteria in urban storm water management. Considerable uncertainty is associated with the models used. This is either ignored or pooled with the inherent event to event variation such as rainfall depth It is here argued that

  2. 300 Area process sewer piping upgrade and 300 Area treated effluent disposal facility discharge to the City of Richland Sewage System, Hanford Site, Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    The U.S. Department of Energy (DOE) is proposing to upgrade the existing 300 Area Process Sewer System by constructing and operating a new process sewer collection system that would discharge to the 300 Area Treated Effluent Disposal Facility. The DOE is also considering the construction of a tie-line from the TEDF to the 300 Area Sanitary Sewer for discharging the process wastewater to the City of Richland Sewage System. The proposed action is needed because the integrity of the old piping in the existing 300 Area Process Sewer System is questionable and effluents might be entering the soil column from leaking pipes. In addition, the DOE has identified a need to reduce anticipated operating costs at the new TEDF. The 300 Area Process Sewer Piping Upgrade (Project L-070) is estimated to cost approximately $9.9 million. The proposed work would involve the construction and operation of a new process sewer collection system. The new system would discharge the effluents to a collection sump and lift station for the TEDF. The TEDF is designed to treat and discharge the process effluent to the Columbia River. The process waste liquid effluent is currently well below the DOE requirements for radiological secondary containment and is not considered a RCRA hazardous waste or a State of Washington Hazardous Waste Management Act dangerous waste. A National Pollutant Discharge Elimination, System (NPDES) permit has been obtained from the U.S. Environmental Protection Agency for discharge to the Columbia River. The proposed action would upgrade the existing 300 Area Process Sewer System by the construction and operation of a new combined gravity, vacuum, and pressurized process sewer collection system consisting of vacuum collection sumps, pressure pump stations, and buried polyvinyl chloride or similar pipe. Two buildings would also be built to house a main collection station and a satellite collection station.

  3. SENZ Umbrellas: taking the world by storm

    NARCIS (Netherlands)

    Smits, A.A.J.; Bodewes, W.

    2011-01-01

    This case describes the start-up of SENZ Umbrellas, a Dutch venture founded by three graduates of Delft University of Technology (the Netherlands) who aimed to introduce an asymmetrical, storm-proof umbrella onto a mass-market where product innovation was limited. It demonstrates the marketing

  4. Tornadic storm avoidance behavior in breeding songbirds

    Science.gov (United States)

    Streby, Henry M.; Kramer, Gunnar R.; Peterson, Sean M.; Lehman, Justin A.; Buehler, David A.; Andersen, David E.

    2015-01-01

    Migration is a common behavior used by animals of many taxa to occupy different habitats during different periods. Migrant birds are categorized as either facultative (i.e., those that are forced to migrate by some proximal cue, often weather) or obligate (i.e., those that migrate on a regular cycle). During migration, obligate migrants can curtail or delay flights in response to inclement weather or until favorable winds prevail, and they can temporarily reorient or reverse direction when ecological or meteorological obstacles are encountered. However, it is not known whether obligate migrants undertake facultative migrations and make large-scale movements in response to proximal cues outside of their regular migration periods. Here, we present the first documentation of obligate long-distance migrant birds undertaking a facultative migration, wherein breeding golden-winged warblers (Vermivora chrysoptera) carrying light-level geolocators performed a >1,500 km 5-day circumvention of a severe tornadic storm. The birds evacuated their breeding territories >24 hr before the arrival of the storm and atmospheric variation associated with it. The probable cue, radiating >1,000 km from tornadic storms, perceived by birds and influencing bird behavior and movements, is infrasound (i.e., sound below the range of human hearing). With the predicted increase in severity and frequency of similar storms as anthropogenic climate change progresses, understanding large-scale behavioral responses of animals to such events will be an important objective of future research.

  5. Okla. Tornado Renews Debate on Storm Safety

    Science.gov (United States)

    Shah, Nirvi

    2013-01-01

    As soon as the winds that left seven students in Moore, Okla., dead last month had calmed, and more storms blew through the same area less than two weeks later, questions about the safety of schools in a region labeled Tornado Alley rose amid the rubble. While better design of new schools and thorough emergency training and practice may be in…

  6. Optimal antiarrhythmic drug therapy for electrical storm

    OpenAIRE

    Sorajja, Dan; Munger, Thomas M.; Shen, Win-Kuang

    2015-01-01

    Abstract Electrical storm, defined as 3 or more separate episodes of ventricular tachycardia or ventricular fibrillation within 24?hours, carries significant morbidity and mortality. These unstable ventricular arrhythmias have been described with a variety of conditions including ischemic heart disease, structural heart disease, and genetic conditions. While implantable cardioverter defibrillator implantation and ablation may be indicated and required, antiarrhythmic medication remains an imp...

  7. Storm impacts on small barrier islands

    DEFF Research Database (Denmark)

    Kroon, Aart; Fruergaard, Mikkel

    The shorelines of the Baltic Sea and the inner coastal waters in Denmark consist of many barrier islands. These sandy barrier islands were mainly formed in the Holocene and are still very dynamic. The present day changes in the morphology are dominantly governed by storm waves and associated high...

  8. Geomagnetic storm under laboratory conditions: randomized experiment

    Science.gov (United States)

    Gurfinkel, Yu I.; Vasin, A. L.; Pishchalnikov, R. Yu; Sarimov, R. M.; Sasonko, M. L.; Matveeva, T. A.

    2017-10-01

    The influence of the previously recorded geomagnetic storm (GS) on human cardiovascular system and microcirculation has been studied under laboratory conditions. Healthy volunteers in lying position were exposed under two artificially created conditions: quiet (Q) and storm (S). The Q regime playbacks a noise-free magnetic field (MF) which is closed to the natural geomagnetic conditions on Moscow's latitude. The S regime playbacks the initially recorded 6-h geomagnetic storm which is repeated four times sequentially. The cardiovascular response to the GS impact was assessed by measuring capillary blood velocity (CBV) and blood pressure (BP) and by the analysis of the 24-h ECG recording. A storm-to-quiet ratio for the cardio intervals (CI) and the heart rate variability (HRV) was introduced in order to reveal the average over group significant differences of HRV. An individual sensitivity to the GS was estimated using the autocorrelation function analysis of the high-frequency (HF) part of the CI spectrum. The autocorrelation analysis allowed for detection a group of subjects of study which autocorrelation functions (ACF) react differently in the Q and S regimes of exposure.

  9. Developing Design Storm Hydrographs for Small Tropical ...

    African Journals Online (AJOL)

    Hydrographs are vital tools in the design and construction of water-control structures in urban and rural systems. The purpose of this study was to explore the development of design storm hydrographs for the small tropical catchment with limited data. In this study, Clark's Unit Hydrograph method was used to develop ...

  10. SeaWiFS: North Pacific Storm

    Science.gov (United States)

    2002-01-01

    An extratropical storm can be seen swirling over the North Pacific just south of Alaska. This SeaWiFS image was collected yesterday at 23:20 GMT. Credit: Provided by the SeaWiFS Project, NASA/Goddard Space Flight Center, and ORBIMAGE

  11. Geomagnetic storm under laboratory conditions: randomized experiment.

    Science.gov (United States)

    Gurfinkel, Yu I; Vasin, A L; Pishchalnikov, R Yu; Sarimov, R M; Sasonko, M L; Matveeva, T A

    2018-04-01

    The influence of the previously recorded geomagnetic storm (GS) on human cardiovascular system and microcirculation has been studied under laboratory conditions. Healthy volunteers in lying position were exposed under two artificially created conditions: quiet (Q) and storm (S). The Q regime playbacks a noise-free magnetic field (MF) which is closed to the natural geomagnetic conditions on Moscow's latitude. The S regime playbacks the initially recorded 6-h geomagnetic storm which is repeated four times sequentially. The cardiovascular response to the GS impact was assessed by measuring capillary blood velocity (CBV) and blood pressure (BP) and by the analysis of the 24-h ECG recording. A storm-to-quiet ratio for the cardio intervals (CI) and the heart rate variability (HRV) was introduced in order to reveal the average over group significant differences of HRV. An individual sensitivity to the GS was estimated using the autocorrelation function analysis of the high-frequency (HF) part of the CI spectrum. The autocorrelation analysis allowed for detection a group of subjects of study which autocorrelation functions (ACF) react differently in the Q and S regimes of exposure.

  12. Tree recovery from ice storm injury

    Science.gov (United States)

    Kevin T. Smith

    2015-01-01

    Ice storms are part of nature, particularly in northeastern North America. The combination of air and surface temperatures, precipitation, and wind that result in damaging layers of ice is very specific, occurring infrequently at any given location. Across the region however, damaging ice is formed in fragmented areas every year. Occasionally as in December 2013 and...

  13. Electrical Storm: Incidence, Prognosis and Therapy.

    Science.gov (United States)

    Sagone, Antonio

    2015-12-01

    The term "electrical storm" indicates a life-threatening clinical condition characterized by the recurrence of hemodynamically unstable ventricular tachycardia and/or ventricular fibrillation, in particular in patients with ICD implanted for primary or secondary prevention. Although there isn't a shared definition of electrical storm, nowadays the most accepted definition refers to three or more separate arrhythmia episodes leading to ICD therapies including antitachycardia pacing or shock occurring over a single 24 hours' time period. Clinical presentation can be dramatic and triggering mechanism are not clear at all yet, but electrical storm is associated with high mortality rates and low patients quality of life, both in the acute phase and in the long term. The first line therapy is based on antiarrhythmic drugs to suppress electrical storm, but in refractory patients, interventions such as catheter ablation or in some cases surgical cardiac sympathetic denervation might be helpful. Anyhow, earlier interventional management can lead to better outcomes than persisting with antiarrhythmic pharmacologic therapy and, when available, an early interventional approach should be preferred.

  14. Thyroid storm and warm autoimmune hemolytic anemia.

    Science.gov (United States)

    Moore, Joseph A; Gliga, Louise; Nagalla, Srikanth

    2017-08-01

    Graves' disease is often associated with other autoimmune disorders, including rare associations with autoimmune hemolytic anemia (AIHA). We describe a unique presentation of thyroid storm and warm AIHA diagnosed concurrently in a young female with hyperthyroidism. The patient presented with nausea, vomiting, diarrhea and altered mental status. Laboratory studies revealed hemoglobin 3.9g/dL, platelets 171×10 9 L -1 , haptoglobin storm and warm AIHA. She was started on glucocorticoids to treat both warm AIHA and thyroid storm, as well as antithyroid medications, propranolol and folic acid. Due to profound anemia and hemodynamic instability, the patient was transfused two units of uncrossmatched packed red blood cells slowly and tolerated this well. She was discharged on methimazole as well as a prolonged prednisone taper, and achieved complete resolution of the thyrotoxicosis and anemia at one month. Hyperthyroidism can affect all three blood cell lineages of the hematopoietic system. Anemia can be seen in 10-20% of patients with thyrotoxicosis. Several autoimmune processes can lead to anemia in Graves' disease, including pernicious anemia, celiac disease, and warm AIHA. This case illustrates a rarely described presentation of a patient with Graves' disease presenting with concurrent thyroid storm and warm AIHA. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Fine structure in fast drift storm bursts

    International Nuclear Information System (INIS)

    McConnell, D.; Ellis, G.R.A.

    1981-01-01

    Recent observations with high time resolution of fast drift storm (FDS) solar bursts are described. A new variety of FDS bursts characterised by intensity maxima regularly placed in the frequency domain is reported. Possible interpretations of this are mentioned and the implications of the short duration of FDS bursts are discussed. (orig.)

  16. DRDC Support to Exercise Cyber Storm III

    Science.gov (United States)

    2011-10-01

    d’intervention fédéraux portant sur les incidents cybernétiques sont encore relativement peu élaborés et insuffisamment développés et un examen des plans examinés...9 2.7 CSIII Ethics Protocol...30 Annex C .. Exercise Cyber Storm III Ethics

  17. Geomagnetic Storm Impact On GPS Code Positioning

    Science.gov (United States)

    Uray, Fırat; Varlık, Abdullah; Kalaycı, İbrahim; Öǧütcü, Sermet

    2017-04-01

    This paper deals with the geomagnetic storm impact on GPS code processing with using GIPSY/OASIS research software. 12 IGS stations in mid-latitude were chosen to conduct the experiment. These IGS stations were classified as non-cross correlation receiver reporting P1 and P2 (NONCC-P1P2), non-cross correlation receiver reporting C1 and P2 (NONCC-C1P2) and cross-correlation (CC-C1P2) receiver. In order to keep the code processing consistency between the classified receivers, only P2 code observations from the GPS satellites were processed. Four extreme geomagnetic storms October 2003, day of the year (DOY), 29, 30 Halloween Storm, November 2003, DOY 20, November 2004, DOY 08 and four geomagnetic quiet days in 2005 (DOY 92, 98, 99, 100) were chosen for this study. 24-hour rinex data of the IGS stations were processed epoch-by-epoch basis. In this way, receiver clock and Earth Centered Earth Fixed (ECEF) Cartesian Coordinates were solved for a per-epoch basis for each day. IGS combined broadcast ephemeris file (brdc) were used to partly compensate the ionospheric effect on the P2 code observations. There is no tropospheric model was used for the processing. Jet Propulsion Laboratory Application Technology Satellites (JPL ATS) computed coordinates of the stations were taken as true coordinates. The differences of the computed ECEF coordinates and assumed true coordinates were resolved to topocentric coordinates (north, east, up). Root mean square (RMS) errors for each component were calculated for each day. The results show that two-dimensional and vertical accuracy decreases significantly during the geomagnetic storm days comparing with the geomagnetic quiet days. It is observed that vertical accuracy is much more affected than the horizontal accuracy by geomagnetic storm. Up to 50 meters error in vertical component has been observed in geomagnetic storm day. It is also observed that performance of Klobuchar ionospheric correction parameters during geomagnetic storm

  18. Probabilistic storm surge inundation maps for Metro Manila based on Philippine public storm warning signals

    Science.gov (United States)

    Tablazon, J.; Caro, C. V.; Lagmay, A. M. F.; Briones, J. B. L.; Dasallas, L.; Lapidez, J. P.; Santiago, J.; Suarez, J. K.; Ladiero, C.; Gonzalo, L. A.; Mungcal, M. T. F.; Malano, V.

    2015-03-01

    A storm surge is the sudden rise of sea water over the astronomical tides, generated by an approaching storm. This event poses a major threat to the Philippine coastal areas, as manifested by Typhoon Haiyan on 8 November 2013. This hydro-meteorological hazard is one of the main reasons for the high number of casualties due to the typhoon, with 6300 deaths. It became evident that the need to develop a storm surge inundation map is of utmost importance. To develop these maps, the Nationwide Operational Assessment of Hazards under the Department of Science and Technology (DOST-Project NOAH) simulated historical tropical cyclones that entered the Philippine Area of Responsibility. The Japan Meteorological Agency storm surge model was used to simulate storm surge heights. The frequency distribution of the maximum storm surge heights was calculated using simulation results of tropical cyclones under a specific public storm warning signal (PSWS) that passed through a particular coastal area. This determines the storm surge height corresponding to a given probability of occurrence. The storm surge heights from the model were added to the maximum astronomical tide data from WXTide software. The team then created maps of inundation for a specific PSWS using the probability of exceedance derived from the frequency distribution. Buildings and other structures were assigned a probability of exceedance depending on their occupancy category, i.e., 1% probability of exceedance for critical facilities, 10% probability of exceedance for special occupancy structures, and 25% for standard occupancy and miscellaneous structures. The maps produced show the storm-surge-vulnerable areas in Metro Manila, illustrated by the flood depth of up to 4 m and extent of up to 6.5 km from the coastline. This information can help local government units in developing early warning systems, disaster preparedness and mitigation plans, vulnerability assessments, risk-sensitive land use plans, shoreline

  19. Motivations and sensation seeking characteristics of recreational storm chasers

    Science.gov (United States)

    Shuangyu Xu; Sonja Wilhelm Stanis; Carla Barbieri; Jiawen. Chen

    2012-01-01

    Little is known about recreational storm chasing, a type of risk recreation that has increased in popularity since the 1990s. This study was conducted to understand factors associated with participation in recreational storm chasing in the United States. Particularly, this study assessed the motivations and sensation seeking attributes of recreational storm chasers, as...

  20. Spotter's Guide for Identifying and Reporting Severe Local Storms.

    Science.gov (United States)

    National Oceanic and Atmospheric Administration (DOC), Rockville, MD.

    This guide is designed to assist personnel working in the National Weather Service's Severe Local Storm Spotter Networks in identifying and reporting severe local storms. Provided are pictures of cloud types for severe storms including tornadoes, hail, thunder, lightning, heavy rains, and waterspouts. Instructions for key indications to watch for…

  1. 46 CFR 190.25-10 - Storm rails.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Storm rails. 190.25-10 Section 190.25-10 Shipping COAST... ARRANGEMENT Rails and Guards § 190.25-10 Storm rails. (a) On vessels in ocean and coastwise service, suitable storm rails shall be installed in all passageways and at the deckhouse sides where persons on board...

  2. 46 CFR 92.25-10 - Storm rails.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Storm rails. 92.25-10 Section 92.25-10 Shipping COAST... ARRANGEMENT Rails and Guards § 92.25-10 Storm rails. (a) On vessels in ocean and coastwise service, suitable storm rails shall be installed in all passageways and at the deckhouse sides where persons on board...

  3. Statistical Relationship between Sawtooth Oscillations and Geomagnetic Storms

    Directory of Open Access Journals (Sweden)

    Jae-Hun Kim

    2008-06-01

    Full Text Available We have investigated a statistical relationship between sawtooth oscillations and geomagnetic storms during 2000-2004. First of all we selected a total of 154 geomagnetic storms based on the Dst index, and distinguished between different drivers such as Coronal Mass Ejection (CME and Co-rotating Interaction Region (CIR. Also, we identified a total of 48 sawtooth oscillation events based on geosynchronous energetic particle data for the same 2000-2004 period. We found that out of the 154 storms identified, 47 storms indicated the presence of sawtooth oscillations. Also, all but one sawtooth event identified occurred during a geomagnetic storm interval. It was also found that sawtooth oscillation events occur more frequently for storms driven by CME (˜62% than for storms driven by CIR (˜30%. In addition, sawtooth oscillations occurred mainly (˜82% in the main phase of storms for CME-driven storms while they occurred mostly (˜78% during the storm recovery phase for CIR-driven storms. Next we have examined the average characteristics of the Bz component of IMF, and solar wind speed, which were the main components for driving geomagnetic storm. We found that for most of the sawtooth events, the IMF Bz corresponds to --15 to 0 nT and the solar wind speed was in the range of 400˜700 km/s. We found that there was a weak tendency that the number of teeth for a given sawtooth event interval was proportional to the southward IMF Bz magnitude.

  4. Evaluation of the STORM model storm-time corrections for middle latitude

    Czech Academy of Sciences Publication Activity Database

    Burešová, Dalia; McKinnell, L.- A.; Šindelářová, Tereza; de la Morena, B. A.

    2010-01-01

    Roč. 46, č. 8 (2010), s. 1039-1046 ISSN 0273-1177 R&D Projects: GA ČR GA205/08/1356; GA AV ČR 1QS300120506 Institutional research plan: CEZ:AV0Z30420517 Keywords : Ionosphere * Geomagnetic storms * STORM model * International Reference Ionosphere (IRI) Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 1.076, year: 2010

  5. No Calm After the Storm: A Systematic Review of Human Health Following Flood and Storm Disasters.

    Science.gov (United States)

    Saulnier, Dell D; Brolin Ribacke, Kim; von Schreeb, Johan

    2017-10-01

    Introduction How the burden of disease varies during different phases after floods and after storms is essential in order to guide a medical response, but it has not been well-described. The objective of this review was to elucidate the health problems following flood and storm disasters. A literature search of the databases Medline (US National Library of Medicine, National Institutes of Health; Bethesda, Maryland USA); Cinahl (EBSCO Information Services; Ipswich, Massachusetts USA); Global Health (EBSCO Information Services; Ipswich, Massachusetts USA); Web of Science Core Collection (Thomson Reuters; New York, New York USA); Embase (Elsevier; Amsterdam, Netherlands); and PubMed (National Center for Biotechnology Information, National Institutes of Health; Bethesda, Maryland USA) was conducted in June 2015 for English-language research articles on morbidity or mortality and flood or storm disasters. Articles on mental health, interventions, and rescue or health care workers were excluded. Data were extracted from articles that met the eligibility criteria and analyzed by narrative synthesis. The review included 113 studies. Poisonings, wounds, gastrointestinal infections, and skin or soft tissue infections all increased after storms. Gastrointestinal infections were more frequent after floods. Leptospirosis and diabetes-related complications increased after both. The majority of changes occurred within four weeks of floods or storms. Health changes differently after floods and after storms. There is a lack of data on the health effects of floods alone, long-term changes in health, and the strength of the association between disasters and health problems. This review highlights areas of consideration for medical response and the need for high-quality, systematic research in this area. Saulnier DD , Brolin Ribacke K , von Schreeb J . No calm after the storm: a systematic review of human health following flood and storm disasters. Prehosp Disaster Med. 2017;32(5):568-579.

  6. Evaluating rain gardens as a method to reduce the impact of sewer overflows in sources of drinking water.

    Science.gov (United States)

    Autixier, Laurène; Mailhot, Alain; Bolduc, Samuel; Madoux-Humery, Anne-Sophie; Galarneau, Martine; Prévost, Michèle; Dorner, Sarah

    2014-11-15

    The implications of climate change and changing precipitation patterns need to be investigated to evaluate mitigation measures for source water protection. Potential solutions need first to be evaluated under present climate conditions to determine their utility as climate change adaptation strategies. An urban drainage network receiving both stormwater and wastewater was studied to evaluate potential solutions to reduce the impact of combined sewer overflows (CSOs) in a drinking water source. A detailed hydraulic model was applied to the drainage basin to model the implementation of best management practices at a drainage basin scale. The model was calibrated and validated with field data of CSO flows for seven events from a survey conducted in 2009 and 2010. Rain gardens were evaluated for their reduction of volumes of water entering the drainage network and of CSOs. Scenarios with different levels of implementation were considered and evaluated. Of the total impervious area within the basin directly connected to the sewer system, a maximum of 21% could be alternately directed towards rain gardens. The runoff reductions for the entire catchment ranged from 12.7% to 19.4% depending on the event considered. The maximum discharged volume reduction ranged from 13% to 62% and the maximum peak flow rate reduction ranged from 7% to 56%. Of concern is that in-sewer sediment resuspension is an important process to consider with regard to the efficacy of best management practices aimed at reducing extreme loads and concentrations. Rain gardens were less effective for large events, which are of greater importance for drinking water sources. These practices could increase peak instantaneous loads as a result of greater in-sewer resuspension during large events. Multiple interventions would be required to achieve the objectives of reducing the number, total volumes and peak contaminant loads of overflows upstream of drinking water intakes. Copyright © 2014 Elsevier B.V. All

  7. Experimental calibration and validation of sewer/surface flow exchange equations in steady and unsteady flow conditions

    Science.gov (United States)

    Rubinato, Matteo; Martins, Ricardo; Kesserwani, Georges; Leandro, Jorge; Djordjević, Slobodan; Shucksmith, James

    2017-09-01

    The linkage between sewer pipe flow and floodplain flow is recognised to induce an important source of uncertainty within two-dimensional (2D) urban flood models. This uncertainty is often attributed to the use of empirical hydraulic formulae (the one-dimensional (1D) weir and orifice steady flow equations) to achieve data-connectivity at the linking interface, which require the determination of discharge coefficients. Because of the paucity of high resolution localised data for this type of flows, the current understanding and quantification of a suitable range for those discharge coefficients is somewhat lacking. To fulfil this gap, this work presents the results acquired from an instrumented physical model designed to study the interaction between a pipe network flow and a floodplain flow. The full range of sewer-to-surface and surface-to-sewer flow conditions at the exchange zone are experimentally analysed in both steady and unsteady flow regimes. Steady state measured discharges are first analysed considering the relationship between the energy heads from the sewer flow and the floodplain flow; these results show that existing weir and orifice formulae are valid for describing the flow exchange for the present physical model, and yield new calibrated discharge coefficients for each of the flow conditions. The measured exchange discharges are also integrated (as a source term) within a 2D numerical flood model (a finite volume solver to the 2D Shallow Water Equations (SWE)), which is shown to reproduce the observed coefficients. This calibrated numerical model is then used to simulate a series of unsteady flow tests reproduced within the experimental facility. Results show that the numerical model overestimated the values of mean surcharge flow rate. This suggests the occurrence of additional head losses in unsteady conditions which are not currently accounted for within flood models calibrated in steady flow conditions.

  8. Investigation of the sources and fate of radioactive discharges to public sewers

    International Nuclear Information System (INIS)

    Titley, J.; Carey, A.; Crockett, G.

    2000-01-01

    The practise of disposing of small amounts of liquid radioactive waste from non-nuclear organisations to public sewer systems, is currently being reviewed by the Environment Agency, Scottish Environmental Protection Agency and the Industrial Pollution and Radiochemical Inspectorate. Changing sewage treatment and disposal practises, particularly the increasing use of incineration to treat sewage sludge in urban areas, have prompted this review. This study was undertaken as part of the review process to determine whether disposal into the public sewer system remains a safe disposal option. This report describes a study to investigate the sources and fates of authorised discharges of radionuclides into the sewer system. Sewage transport, treatment, discharge and incineration systems are described and the fate of radionuclides in the systems considered. A model (SMART) was developed to predict radionuclide behaviour through these systems and calculate the resulting doses. Case studies of two large urban sewerage systems were carried out in Leeds and Central London. Leeds is served by one sewage treatment works at Knostrop, which receives disposals of ten radionuclides from six disposers. Up to seven of the radionuclides were measurable in effluents, sludges or incinerator ash at the works. Naturally occurring and fallout radionuclides were also detected. Central London is served by one large works at Beckton which receives disposals of twenty radionuclides from 65 disposers. Up to ten of the disposed radionuclides, plus naturally occurring and fallout radionuclides were detected in effluents, sludges, incinerator cake or ash at Beckton. For both sites the largest authorised disposals were of Tc-99m, C-14, I-125, I-131 and H-3. The behaviour of radionuclides during incineration was assessed using measurements and literature values. The radiological implications of disposals in Leeds and Central London were assessed using the model SMART and by measuring dose rates

  9. Earlier vegetation green-up has reduced spring dust storms.

    Science.gov (United States)

    Fan, Bihang; Guo, Li; Li, Ning; Chen, Jin; Lin, Henry; Zhang, Xiaoyang; Shen, Miaogen; Rao, Yuhan; Wang, Cong; Ma, Lei

    2014-10-24

    The observed decline of spring dust storms in Northeast Asia since the 1950s has been attributed to surface wind stilling. However, spring vegetation growth could also restrain dust storms through accumulating aboveground biomass and increasing surface roughness. To investigate the impacts of vegetation spring growth on dust storms, we examine the relationships between recorded spring dust storm outbreaks and satellite-derived vegetation green-up date in Inner Mongolia, Northern China from 1982 to 2008. We find a significant dampening effect of advanced vegetation growth on spring dust storms (r = 0.49, p = 0.01), with a one-day earlier green-up date corresponding to a decrease in annual spring dust storm outbreaks by 3%. Moreover, the higher correlation (r = 0.55, p storm outbreak ratio (the ratio of dust storm outbreaks to times of strong wind events) indicates that such effect is independent of changes in surface wind. Spatially, a negative correlation is detected between areas with advanced green-up dates and regional annual spring dust storms (r = -0.49, p = 0.01). This new insight is valuable for understanding dust storms dynamics under the changing climate. Our findings suggest that dust storms in Inner Mongolia will be further mitigated by the projected earlier vegetation green-up in the warming world.

  10. Storm water permitting for oil and gas facilities

    International Nuclear Information System (INIS)

    de Blanc, P.C.

    1991-01-01

    After several false starts, the US Environmental Protection Agency (EPA) published new federal storm water regulations in the November 16, 1990 Federal Register. These regulations identify facilities which must apply for a storm water permit and detail permit application requirements. The regulations appear at 40 CFR 122 Subpart B and became effective December 17, 1990. An outline of these regulations and their applicability to oil and gas facilities is presented. They are: facilities which require a storm water permit; types of storm water permits; permit application deadlines; permit application forms; facilities with existing storm water permits; storm water permit application data requirements; storm water sampling and analysis requirements; and EPA contacts for additional information

  11. A case independent approach on the impact of climate change effects on combined sewer system performance.

    Science.gov (United States)

    Kleidorfer, M; Möderl, M; Sitzenfrei, R; Urich, C; Rauch, W

    2009-01-01

    Design and construction of urban drainage systems has to be done in a predictive way, as the average lifespan of such investments is several decades. The design engineer has to predict many influencing factors and scenarios for future development of a system (e.g. change in land use, population, water consumption and infiltration measures). Furthermore, climate change can cause increased rain intensities which leads to an additional impact on drainage systems. In this paper we compare the behaviour of different performance indicators of combined sewer systems when taking into account long-term environmental change effects (change in rainfall characteristics, change in impervious area and change in dry weather flow). By using 250 virtual case studies this approach is--in principle--a Monte Carlo Simulation in which not only parameter values are varied but the entire system structure and layout is changed in each run. Hence, results are more general and case-independent. For example the consideration of an increase of rainfall intensities by 20% has the same effect as an increase of impervious area of +40%. Such an increase of rainfall intensities could be compensated by infiltration measures in current systems which lead to a reduction of impervious area by 30%.

  12. Advances in concrete materials for sewer systems affected by microbial induced concrete corrosion: A review.

    Science.gov (United States)

    Grengg, Cyrill; Mittermayr, Florian; Ukrainczyk, Neven; Koraimann, Günther; Kienesberger, Sabine; Dietzel, Martin

    2018-05-01

    Microbial induced concrete corrosion (MICC) is recognized as one of the main degradation mechanisms of subsurface infrastructure worldwide, raising the demand for sustainable construction materials in corrosive environments. This review aims to summarize the key research progress acquired during the last decade regarding the understanding of MICC reaction mechanisms and the development of durable materials from an interdisciplinary perspective. Special focus was laid on aspects governing concrete - micoorganisms interaction since being the central process steering biogenic acid corrosion. The insufficient knowledge regarding the latter is proposed as a central reason for insufficient progress in tailored material development for aggressive wastewater systems. To date no cement-based material exists, suitable to withstand the aggressive conditions related to MICC over its entire service life. Research is in particular needed on the impact of physiochemical material parameters on microbial community structure, growth characteristics and limitations within individual concrete speciation. Herein an interdisciplinary approach is presented by combining results from material sciences, microbiology, mineralogy and hydrochemistry to stimulate the development of novel and sustainable materials and mitigation strategies for MICC. For instance, the application of antibacteriostatic agents is introduced as an effective instrument to limit microbial growth on concrete surfaces in aggressive sewer environments. Additionally, geopolymer concretes are introduced as highly resistent in acid environments, thus representing a possible green alternative to conventional cement-based construction materials. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Quantifying rainfall-derived inflow and infiltration in sanitary sewer systems based on conductivity monitoring

    Science.gov (United States)

    Zhang, Mingkai; Liu, Yanchen; Cheng, Xun; Zhu, David Z.; Shi, Hanchang; Yuan, Zhiguo

    2018-03-01

    Quantifying rainfall-derived inflow and infiltration (RDII) in a sanitary sewer is difficult when RDII and overflow occur simultaneously. This study proposes a novel conductivity-based method for estimating RDII. The method separately decomposes rainfall-derived inflow (RDI) and rainfall-induced infiltration (RII) on the basis of conductivity data. Fast Fourier transform was adopted to analyze variations in the flow and water quality during dry weather. Nonlinear curve fitting based on the least squares algorithm was used to optimize parameters in the proposed RDII model. The method was successfully applied to real-life case studies, in which inflow and infiltration were successfully estimated for three typical rainfall events with total rainfall volumes of 6.25 mm (light), 28.15 mm (medium), and 178 mm (heavy). Uncertainties of model parameters were estimated using the generalized likelihood uncertainty estimation (GLUE) method and were found to be acceptable. Compared with traditional flow-based methods, the proposed approach exhibits distinct advantages in estimating RDII and overflow, particularly when the two processes happen simultaneously.

  14. Assessment of annual pollutant loads in combined sewers from continuous turbidity measurements: sensitivity to calibration data.

    Science.gov (United States)

    Lacour, C; Joannis, C; Chebbo, G

    2009-05-01

    This article presents a methodology for assessing annual wet weather Suspended Solids (SS) and Chemical Oxygen Demand (COD) loads in combined sewers, along with the associated uncertainties from continuous turbidity measurements. The proposed method is applied to data from various urban catchments in the cities of Paris and Nantes. The focus here concerns the impact of the number of rain events sampled for calibration (i.e. through establishing linear SS/turbidity or COD/turbidity relationships) on the uncertainty of annual pollutant load assessments. Two calculation methods are investigated, both of which rely on Monte Carlo simulations: random assignment of event-specific calibration relationships to each individual rain event, and the use of an overall relationship built from the entire available data set. Since results indicate a fairly low inter-event variability for calibration relationship parameters, an accurate assessment of pollutant loads can be derived, even when fewer than 10 events are sampled for calibration purposes. For operational applications, these results suggest that turbidity could provide a more precise evaluation of pollutant loads at lower cost than typical sampling methods.

  15. Model evaluation of faecal contamination in coastal areas affected by urban rivers receiving combined sewer overflows.

    Science.gov (United States)

    Shibata, T; Kojima, K; Lee, S A; Furumai, H

    2014-01-01

    Odaiba seaside park is one of the most popular waterfronts in Tokyo Bay, but is easily affected by wet weather pollutant loads through combined sewer overflows (CSOs). The monitoring data of Escherichia coli clearly showed high faecal contamination after a rainfall event on 9-11 November 2007. We estimated the amounts of discharge volume and E. coli pollutant loads of urban rivers receiving CSO from rainfall chambers as well as pumping stations and primary effluent discharge. The result suggested that Sumida River and Meguro River were more influential to the Odaiba coastal area than other sources including the nearest wastewater treatment plant. Subsequently, we simulated the dynamic behaviour of E. coli by a three-dimensional (3D) hydro-dynamic and water quality model. The model simulation reproduced that E. coli concentration after the rainfall event increased rapidly at first and later gradually decreased. The simulations with and without inflow pollutant loads from urban rivers suggested that the E. coli concentration can be influenced by the Meguro River just after the rainfall event and Sumida River about 1 week later. From the spatial and temporal distribution of surface E. coli concentration, after at least 6 days from the rainfall event, high faecal contamination spread to the whole of the coastal area.

  16. Chemical disinfection of combined sewer overflow waters using performic acid or peracetic acids.

    Science.gov (United States)

    Chhetri, Ravi Kumar; Thornberg, Dines; Berner, Jesper; Gramstad, Robin; Öjstedt, Ulrik; Sharma, Anitha Kumari; Andersen, Henrik Rasmus

    2014-08-15

    We investigated the possibility of applying performic acid (PFA) and peracetic acid (PAA) for disinfection of combined sewer overflow (CSO) in existing CSO management infrastructures. The disinfection power of PFA and PAA towards Escherichia coli (E. coli) and Enterococcus was studied in batch-scale and pre-field experiments. In the batch-scale experiment, 2.5 mg L(-1) PAA removed approximately 4 log unit of E. coli and Enterococcus from CSO with a 360 min contact time. The removal of E. coli and Enterococcus from CSO was always around or above 3 log units using 2-4 mg L(-1) PFA; with a 20 min contact time in both batch-scale and pre-field experiments. There was no toxicological effect measured by Vibrio fischeri when CSO was disinfected with PFA; a slight toxic effect was observed on CSO disinfected with PAA. When the design for PFA based disinfection was applied to CSO collected from an authentic event, the disinfection efficiencies were confirmed and degradation rates were slightly higher than predicted in simulated CSO. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Production of durable and cost effective sewer pipes using petroleum and industrial waste by-products

    Directory of Open Access Journals (Sweden)

    El Gamal Maisa

    2017-01-01

    Full Text Available The Arabian Gulf environment has an adverse impact on concrete structures because of the high ambient temperature, humidity, salt contaminated dust, sea water and underground salts. As an innovative solution, reinforced modified sulfur concrete (MSC pipes are recognized as a durable and economical solution for deterioration of pipelines. This work describes the manufacture and characterization of new MSC based on a cost effective sulfur modification process. Bitumen, a by-product from crude oil refining process was used to modify elemental sulfur and enhance its physical, mechanical properties, and mostly to increase its corrosive resistivity. The study has focused on optimizing the proportions of an offered MSC mixes that are composed of modified sulfur (MS as a binder, crushed sand, dune sand and ladle furnace (LF slag as aggregates, and ground granulated blast furnace slag (GGFBS as a filler. To maximize the physical and mechanical properties of MSC sewer pipes, different mixtures were prepared and investigated. The optimum mix of MSC has a maximum compressive strength of 64 MPa, maximum splitting tensile strength of 4.5 MPa, maximum flexural strength of 21 MP, with a high corrosion resistance in acidic and salty environments.

  18. Performance assessment of a vertical flow constructed wetland treating unsettled combined sewer overflow.

    Science.gov (United States)

    Pálfy, T G; Gerodolle, M; Gourdon, R; Meyer, D; Troesch, S; Molle, P

    2017-06-01

    The performance of a vertical flow constructed wetland for combined sewer overflow treatment (CSO CW) has been evaluated. The full-scale site has been monitored for 3 years for major pollutants and for two load events for a range of micropollutants (metals, metalloids and polycyclic aromatic hydrocarbons (PAHs)). Performance were predominantly high (97% for total suspended solids (TSS), 80% for chemical oxygen demand (COD), 72% for NH 4 -N), even if several loads were extremely voluminous, pushing the filter to its limits. Two different filter materials (a 4:1 mixture of sand and zeolite and natural pozzolana) showed similar treatment performance. Furthermore, environmental factors were correlated with COD removal efficiency. The greatest influencers of COD removal efficiency were the inlet dissolved COD concentrations and the duration and potential evapotranspiration during inter-event periods. Furthermore, sludge was analysed for quality and a sludge depth map was created. The map, and calculating the changes in sludge volume, helped to understand solid accumulation dynamics.

  19. A rat in the sewer: How mental imagery interacts with object recognition.

    Science.gov (United States)

    Karimpur, Harun; Hamburger, Kai

    2018-01-01

    The role of mental imagery has been puzzling researchers for more than two millennia. Both positive and negative effects of mental imagery on information processing have been discussed. The aim of this work was to examine how mental imagery affects object recognition and associative learning. Based on different perceptual and cognitive accounts we tested our imagery-induced interaction hypothesis in a series of two experiments. According to that, mental imagery could lead to (1) a superior performance in object recognition and associative learning if these objects are imagery-congruent (semantically) and to (2) an inferior performance if these objects are imagery-incongruent. In the first experiment, we used a static environment and tested associative learning. In the second experiment, subjects encoded object information in a dynamic environment by means of a virtual sewer system. Our results demonstrate that subjects who received a role adoption task (by means of guided mental imagery) performed better when imagery-congruent objects were used and worse when imagery-incongruent objects were used. We finally discuss our findings also with respect to alternative accounts and plead for a multi-methodological approach for future research in order to solve this issue.

  20. The evaluation of rainfall influence on combined sewer overflows characteristics: the Berlin case study.

    Science.gov (United States)

    Sandoval, S; Torres, A; Pawlowsky-Reusing, E; Riechel, M; Caradot, N

    2013-01-01

    The present study aims to explore the relationship between rainfall variables and water quality/quantity characteristics of combined sewer overflows (CSOs), by the use of multivariate statistical methods and online measurements at a principal CSO outlet in Berlin (Germany). Canonical correlation results showed that the maximum and average rainfall intensities are the most influential variables to describe CSO water quantity and pollutant loads whereas the duration of the rainfall event and the rain depth seem to be the most influential variables to describe CSO pollutant concentrations. The analysis of partial least squares (PLS) regression models confirms the findings of the canonical correlation and highlights three main influences of rainfall on CSO characteristics: (i) CSO water quantity characteristics are mainly influenced by the maximal rainfall intensities, (ii) CSO pollutant concentrations were found to be mostly associated with duration of the rainfall and (iii) pollutant loads seemed to be principally influenced by dry weather duration before the rainfall event. The prediction quality of PLS models is rather low (R² < 0.6) but results can be useful to explore qualitatively the influence of rainfall on CSO characteristics.

  1. Managing sewer solids for the reduction of foul flush effects--Forfar WTP.

    Science.gov (United States)

    Fraser, A G; Sakrabani, R; Ashley, R M; Johnstone, F M

    2002-01-01

    In times of high sewer flow, conditions can exist which enable previously deposited material to be re-entrained back into the body of the flow column. Pulses of this highly polluted flow have been recorded in many instances at the recently constructed wastewater treatment plant (WTP) in Forfar, Scotland. Investigations have been undertaken to characterise the incoming flows and to suggest remedial measures to manage the quality fluctuations. Initial visits to the works and incoming pipes indicated a high degree of sediment deposition in the two inlet pipes. Analyses were carried out and consequently, changes to the hydraulic regime were made. Measurements of sediment level, sediment quality, wall slime and bulk water quality were monitored in the period following the remedial works to observe any improvements. Dramatic alterations in each of the determinands measured were recorded. Analyses were then undertaken to determine long term sediment behaviour and to assess the future usefulness of existing upstream sediment traps. It was concluded that with proper maintenance of the traps, the new hydraulic regime is sufficient to prevent further significant build up of sediment deposits and reduce impacts on the WTP. Further investigations made by North of Scotland Water Authority highlighted trade inputs to the system which may also have contributed to the now managed foul flush problem.

  2. Nonlinear chaotic model for predicting storm surges

    Directory of Open Access Journals (Sweden)

    M. Siek

    2010-09-01

    Full Text Available This paper addresses the use of the methods of nonlinear dynamics and chaos theory for building a predictive chaotic model from time series. The chaotic model predictions are made by the adaptive local models based on the dynamical neighbors found in the reconstructed phase space of the observables. We implemented the univariate and multivariate chaotic models with direct and multi-steps prediction techniques and optimized these models using an exhaustive search method. The built models were tested for predicting storm surge dynamics for different stormy conditions in the North Sea, and are compared to neural network models. The results show that the chaotic models can generally provide reliable and accurate short-term storm surge predictions.

  3. Coronal mass ejections and large geomagnetic storms

    International Nuclear Information System (INIS)

    Gosling, J.T.; Bame, S.J.; McComas, D.J.; Phillips, J.L.

    1990-01-01

    Previous work indicates that coronal mass ejection (CME) events in the solar wind at 1 AU can be identified by the presence of a flux of counterstreaming solar wind halo electrons (above about 80 eV). Using this technique to identify CMEs in 1 AU plasma data, the authors find that most large geomagnetic storms during the interval surrounding the last solar maximum (Aug. 1978-Oct. 1982) were associated with Earth-passage of interplanetary disturbances in which the Earth encountered both a shock and the CME driving the shock. However, only about one CME in six encountered by Earth was effective in causing a large geomagnetic storm. Slow CMEs which did not interact strongly with the ambient solar wind ahead were particularly ineffective in a geomagnetic sense

  4. Modeling the ocean effect of geomagnetic storms

    DEFF Research Database (Denmark)

    Olsen, Nils; Kuvshinov, A.

    2004-01-01

    At coastal sites, geomagnetic variations for periods shorter than a few days are strongly distorted by the conductivity of the nearby sea-water. This phenomena, known as the ocean (or coast) effect, is strongest in the magnetic vertical component. We demonstrate the ability to predict the ocean...... if the oceans are considered. Our analysis also indicates a significant local time asymmetry (i.e., contributions from spherical harmonics other than P-I(0)), especially during the main phase of the storm....

  5. Elliptical magnetic clouds and geomagnetic storms

    Czech Academy of Sciences Publication Activity Database

    Antoniadou, I.; Geranios, A.; Vandas, Marek; Panagopoulou, M.; Zacharopoulou, O.; Malandraki, O.

    2008-01-01

    Roč. 56, 3-4 (2008), s. 492-500 ISSN 0032-0633 R&D Projects: GA AV ČR 1QS300120506; GA ČR GA205/06/0875 Institutional research plan: CEZ:AV0Z10030501 Keywords : magnetic clouds * geomagnetic storms * solar wind Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 2.506, year: 2008

  6. AI techniques in geomagnetic storm forecasting

    Science.gov (United States)

    Lundstedt, Henrik

    This review deals with how geomagnetic storms can be predicted with the use of Artificial Intelligence (AI) techniques. Today many different Al techniques have been developed, such as symbolic systems (expert and fuzzy systems) and connectionism systems (neural networks). Even integrations of AI techniques exist, so called Intelligent Hybrid Systems (IHS). These systems are capable of learning the mathematical functions underlying the operation of non-linear dynamic systems and also to explain the knowledge they have learned. Very few such powerful systems exist at present. Two such examples are the Magnetospheric Specification Forecast Model of Rice University and the Lund Space Weather Model of Lund University. Various attempts to predict geomagnetic storms on long to short-term are reviewed in this article. Predictions of a month to days ahead most often use solar data as input. The first SOHO data are now available. Due to the high temporal and spatial resolution new solar physics have been revealed. These SOHO data might lead to a breakthrough in these predictions. Predictions hours ahead and shorter rely on real-time solar wind data. WIND gives us real-time data for only part of the day. However, with the launch of the ACE spacecraft in 1997, real-time data during 24 hours will be available. That might lead to the second breakthrough for predictions of geomagnetic storms.

  7. Geomagnetic storm effects on GPS based navigation

    Directory of Open Access Journals (Sweden)

    P. V. S. Rama Rao

    2009-05-01

    Full Text Available The energetic events on the sun, solar wind and subsequent effects on the Earth's geomagnetic field and upper atmosphere (ionosphere comprise space weather. Modern navigation systems that use radio-wave signals, reflecting from or propagating through the ionosphere as a means of determining range or distance, are vulnerable to a variety of effects that can degrade the performance of the navigational systems. In particular, the Global Positioning System (GPS that uses a constellation of earth orbiting satellites are affected due to the space weather phenomena.

    Studies made during two successive geomagnetic storms that occurred during the period from 8 to 12 November 2004, have clearly revealed the adverse affects on the GPS range delay as inferred from the Total Electron Content (TEC measurements made from a chain of seven dual frequency GPS receivers installed in the Indian sector. Significant increases in TEC at the Equatorial Ionization anomaly crest region are observed, resulting in increased range delay during the periods of the storm activity. Further, the storm time rapid changes occurring in TEC resulted in a number of phase slips in the GPS signal compared to those on quiet days. These phase slips often result in the loss of lock of the GPS receivers, similar to those that occur during strong(>10 dB L-band scintillation events, adversely affecting the GPS based navigation.

  8. Plasmaspheric noise radiation during geomagnetic storms

    International Nuclear Information System (INIS)

    Larkina, V.I.; Likhter, Ya.I.

    1981-01-01

    Variations of plasmospheric background radiations during geomagnetic storms of different intensity are investigated. Used are results of ELF and VLF radiation measurements as well as electron fluxes of energies Esub(e)>40 keV carried out by Intercosmos 3 and Intercosmos 5 satellites. Dependences of radiation amplitude variations at 1.6 and 25 kHz frequencies on L shell for various geomagnetic activity in the day-time as well as data on variations of quasicaptured electron fluxes at Esub(e)>40 keV, are given. It is shown that experimental data agree with the existing theories of plasmospheric noise excitation. It is concluded that the plasmospheric noise excitation area Lsub(max) is always in the region of gap between radiation belts and inner slope of external radiation belt during magnetic storms. During magnetic storms Lsub(max) area moves simultaneously with the area, where particle flux of the external radiation belt is the most intensive [ru

  9. CALCULATION: PRECIPITATION CHARACTERISITICS FOR STORM WATER MANAGEMENT

    International Nuclear Information System (INIS)

    D. Ambos

    2000-01-01

    This Calculation is intended to satisfy engineering requirements for maximum 60-minute precipitation amounts for 50 and 100-year return periods at and near Yucca Mountain. This data requirement is documented in the ''Interface Control Document for Support Operations to Surface Facilities Operations Functional and Organizational Interfaces'' (CRWMS M and O 1998a). These developed data will supplement the information on 0.1 hour to 6-hour (in 0.1-hour increments) probable maximum precipitation (PMP) presented in the report, ''Precipitation Design Criteria for Storm Water Management'' (CRWMS M and O 1998b). The Reference Information Base (RIB) item, Precipitation ''Characteristics for Storm Water Management'' (M09902RIB00045 .OOO), was developed based on CRWMS M and O (1998b) and will be supplemented (via revision) with the information developed in this Calculation. The ''Development Plan for the Calculation: Precipitation Characteristics for Storm Water Management'' (CRWMS M and O 2000) was prepared in accordance with AP-2.l3Q, ''Technical Product Development Planning''. This calculation was developed in accordance with AP-3.12Q, Rev. O/ICN 2

  10. [Thyroid emergencies : Thyroid storm and myxedema coma].

    Science.gov (United States)

    Spitzweg, C; Reincke, M; Gärtner, R

    2017-10-01

    Thyroid emergencies are rare life-threatening endocrine conditions resulting from either decompensated thyrotoxicosis (thyroid storm) or severe thyroid hormone deficiency (myxedema coma). Both conditions develop out of a long-standing undiagnosed or untreated hyper- or hypothyroidism, respectively, precipitated by an acute stress-associated event, such as infection, trauma, or surgery. Cardinal features of thyroid storm are myasthenia, cardiovascular symptoms, in particular tachycardia, as well as hyperthermia and central nervous system dysfunction. The diagnosis is made based on clinical criteria only as thyroid hormone measurements do not differentiate between thyroid storm and uncomplicated hyperthyroidism. In addition to critical care measures therapy focusses on inhibition of thyroid hormone synthesis and secretion (antithyroid drugs, perchlorate, Lugol's solution, cholestyramine, thyroidectomy) as well as inhibition of thyroid hormone effects in the periphery (β-blocker, glucocorticoids).Cardinal symptoms of myxedema coma are hypothermia, decreased mental status, and hypoventilation with risk of pneumonia and hyponatremia. The diagnosis is also purely based on clinical criteria as measurements of thyroid hormone levels do not differ between uncomplicated severe hypothyroidism and myxedema coma. In addition to substitution of thyroid hormones and glucocorticoids, therapy focusses on critical care measures to treat hypoventilation and hypercapnia, correction of hyponatremia and hypothermia.Survival of both thyroid emergencies can only be optimized by early diagnosis based on clinical criteria and prompt initiation of multimodal therapy including supportive measures and treatment of the precipitating event.

  11. Local time and cutoff rigidity dependences of storm time increase associated with geomagnetic storms

    International Nuclear Information System (INIS)

    Kudo, S.; Wada, M.; Tanskanen, P.; Kodama, M.

    1987-01-01

    The cosmic ray increases due to considerable depressions of cosmic ray cutoff rigidity during large geomagnetic storms are investigated. Data from a worldwide network of cosmic ray neutron monitors are analyzed for 17 geomagnetic storms which occurred in the quiet phase of the solar activity cycle during 1966-1978. As expected from the longitudinal asymmetry of the low-altitude geomagnetic field during large geomagnetic storms, a significant local time dependence of the increment in the cosmic ray during large geomagnetic storms, a significant local time dependence of the increment in the cosmic ray intensity is obtained. It is shown that the maximum phases of the local time dependence occur at around 1800 LT and that the amplitudes of the local time dependence are consistent with presently available theoretical estimates. The dependence of the increment on the cutoff rigidity is obtained for both the local time dependent part and the local time independent part of the storm time increase. The local time independent part, excluding the randomizing local time dependent part, shows a clear-cut dependence on cutoff rigidity which is consistent with theoretical estimates

  12. Examine Precipitation Extremes in Terms of Storm Properties

    Science.gov (United States)

    Jiang, P.; Yu, Z.; Chen, L.; Gautam, M. R.; Acharya, K.

    2017-12-01

    The increasing potential of the extreme precipitation is of significant societal concern. Changes in precipitation extremes have been mostly examined using extreme precipitation indices or Intensity-Duration-Frequency (IDF) analyses, which often fail to reveal the characteristics of an integrated precipitation event. In this study, we will examine the precipitation extremes in terms of storm properties including storm duration, storm intensity, total storm precipitation, and within storm pattern. Single storm event will be identified and storm properties will be determined based on the hourly precipitation time series in the selected locations in southwest United States. Three types of extreme precipitation event will be recognized using the criteria as (1) longest storm duration; (2) Highest storm intensity; and (3) largest total precipitation over a storm. The trend and variation of extreme precipitation events will be discussed for each criterion. Based on the comparisons of the characteristics of extreme precipitation events identified using different criteria, we will provide guidelines for choosing proper criteria for extreme precipitation analysis in specific location.

  13. Perfect storm: Therapeutic plasma exchange for a patient with thyroid storm.

    Science.gov (United States)

    McGonigle, Andrea M; Tobian, Aaron A R; Zink, Jennifer L; King, Karen E

    2018-02-01

    Thyroid storm is a potentially lethal complication of hyperthyroidism with increased thyroid hormones and exaggerated symptoms of thyrotoxicosis. First-line therapy includes methimazole (MMI) or propylthiouracil (PTU) to block production of thyroid hormones as a bridge toward definitive surgical treatment. Untreated thyroid storm has a mortality rate of up to 30%; this is particularly alarming when patients cannot tolerate or fail pharmacotherapy, especially if they cannot undergo thyroidectomy. Therapeutic plasma exchange (TPE) is an ASFA category III indication for thyroid storm, meaning the optimum role of this therapy is not established, and there are a limited number of cases in the literature. Yet TPE can remove T3 and T4 bound to albumin, autoantibodies, catecholamines and cytokines and is likely beneficial for these patients. We report a patient with thyroid storm who could not tolerate PTU, subsequently failed therapy with MMI, and was not appropriate for thyroidectomy. TPE was therefore performed daily for 4 days (1.0 plasma volume with 5% albumin replacement and 2 U of plasma). Over the treatment course, the patient's thyroid hormones normalized and symptoms of thyroid storm largely resolved; his T3 decreased from 2.27 to 0.81 ng/mL (normal 0.8-2.0), T4 decreased from 4.8 to 1.7 ng/mL (0.8-1.8), heart rate normalized, altered mental status improved, and he converted to normal sinus rhythm. He was ultimately discharged in euthyroid state. He experienced no side effects from his TPE procedures. TPE is a safe and effective treatment for thyroid storm when conventional treatments are not successful or appropriate. © 2017 Wiley Periodicals, Inc.

  14. The differences between storms driven by helmet streamer CIRs and storms driven by pseudostreamer CIRs

    OpenAIRE

    Borovsky, Joseph E.; Denton, Michael

    2013-01-01

    A corotating interaction region (CIR) is formed when fast coronal hole origin solar wind overtakes slow solar wind and forms a region of compressed plasma and magnetic field. The slow wind upstream of the coronal hole fast wind can be either of helmet streamer origin or pseudostreamer origin. For a collection of 125 CIR-driven geomagnetic storms, the slow wind ahead of each CIR is examined; for those storm not containing ejecta, each CIR is categorized as a helmet streamer CIR (74 of the 125 ...

  15. Progress in the Study of Coastal Storm Deposits

    Science.gov (United States)

    Xiong, Haixian; Huang, Guangqing; Fu, Shuqing; Qian, Peng

    2018-05-01

    Numerous studies have been carried out to identify storm deposits and decipher storm-induced sedimentary processes in coastal and shallow-marine areas. This study aims to provide an in-depth review on the study of coastal storm deposits from the following five aspects. 1) The formation of storm deposits is a function of hydrodynamic and sedimentary processes under the constraints of local geological and ecological factors. Many questions remain to demonstrate the genetic links between storm-related processes and a variety of resulting deposits such as overwash deposits, underwater deposits and hummocky cross-stratification (HCS). Future research into the formation of storm deposits should combine flume experiments, field observations and numerical simulations, and make full use of sediment source tracing methods. 2) Recently there has been rapid growth in the number of studies utilizing sediment provenance analysis to investigate the source of storm deposits. The development of source tracing techniques, such as mineral composition, magnetic susceptibility, microfossil and geochemical property, has allowed for better understanding of the depositional processes and environmental changes associated with coastal storms. 3) The role of extreme storms in the sedimentation of low-lying coastal wetlands with diverse ecosystem services has also drawn a great deal of attention. Many investigations have attempted to quantify widespread land loss, vertical marsh sediment accumulation and wetland elevation change induced by major hurricanes. 4) Paleostorm reconstructions based on storm sedimentary proxies have shown many advantages over the instrumental records and historic documents as they allow for the reconstruction of storm activities on millennial or longer time scales. Storm deposits having been used to establish proxies mainly include beach ridges and shelly cheniers, coral reefs, estuary-deltaic storm sequences and overwash deposits. Particularly over the past few

  16. Remaining Sites Verification Package for the 100-F-26:10, 1607-F3 Sanitary Sewer Pipelines (182-F, 183-F, and 151-F Sanitary Sewer Lines), Waste Site Reclassification Form 2007-028

    Energy Technology Data Exchange (ETDEWEB)

    L. M. Dittmer

    2007-12-03

    The 100-F-26:10 waste site includes sanitary sewer lines that serviced the former 182-F, 183-F, and 151-F Buildings. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

  17. Remaining Sites Verification Package for the 100-F-26:10, 1607-F3 Sanitary Sewer Pipelines (182-F, 183-F, and 151-F Sanitary Sewer Lines). Attachment to Waste Site Reclassification Form 2007-028

    International Nuclear Information System (INIS)

    Dittmer, L.M.

    2007-01-01

    The 100-F-26:10 waste site includes sanitary sewer lines that serviced the former 182-F, 183-F, and 151-F Buildings. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River

  18. Cardiorespiratory Failure in Thyroid Storm: Case Report and Literature Review.

    Science.gov (United States)

    Nai, Qiang; Ansari, Mohammad; Pak, Stella; Tian, Yufei; Amzad-Hossain, Mohammed; Zhang, Yanhong; Lou, Yali; Sen, Shuvendu; Islam, Mohammed

    2018-04-01

    Thyroid storm is a potentially fatal manifestation of thyrotoxicosis. Cardiopulmonary failure is the most common cause of death in thyroid storm. Clinicians should keep in mind that thyroid storm complicated with cardiopulmonary failure can be the first presentation of thyrotoxicosis. As early intervention is associated with improved patient outcome, prompt diagnosis based on clinical grounds is of paramount importance in the management of thyrotoxicosis. A high index of suspicion and the ability of early recognition of impending thyroid storm depends on a thorough knowledge of both the typical and atypical clinical features of this illness. Herein, we report a case of thyroid storm presenting as cardiopulmonary failure in a 51-year-old woman with undiagnosed Grave's disease. Additionally, we review the pathophysiology of cardiopulmonary failure associated with thyrotoxicosis and various treatment modalities for thyroid storm.

  19. Cardiorespiratory Failure in Thyroid Storm: Case Report and Literature Review

    Science.gov (United States)

    Nai, Qiang; Ansari, Mohammad; Pak, Stella; Tian, Yufei; Amzad-Hossain, Mohammed; Zhang, Yanhong; Lou, Yali; Sen, Shuvendu; Islam, Mohammed

    2018-01-01

    Thyroid storm is a potentially fatal manifestation of thyrotoxicosis. Cardiopulmonary failure is the most common cause of death in thyroid storm. Clinicians should keep in mind that thyroid storm complicated with cardiopulmonary failure can be the first presentation of thyrotoxicosis. As early intervention is associated with improved patient outcome, prompt diagnosis based on clinical grounds is of paramount importance in the management of thyrotoxicosis. A high index of suspicion and the ability of early recognition of impending thyroid storm depends on a thorough knowledge of both the typical and atypical clinical features of this illness. Herein, we report a case of thyroid storm presenting as cardiopulmonary failure in a 51-year-old woman with undiagnosed Grave’s disease. Additionally, we review the pathophysiology of cardiopulmonary failure associated with thyrotoxicosis and various treatment modalities for thyroid storm. PMID:29511425

  20. North Plant co-generation project for South Davis County Sewer Improvement District

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, L.S. [Aqua Environmental Services, Inc., Bountiful, UT (United States)

    1993-12-31

    In the summer of 1988, the South Davis County Sewer Improvement District (SDCSID) learned of a grant/loan program being administered by the Utah State Department of Energy(DOE) for projects that demonstrate new and innovative ways of conserving energy or utilizing renewable energy sources. The SDCSID applied for and received from the DOE both a grant and a no-interest loan to finance half of the cost of a co-generation project at the North Wastewater Treatment Plant. This co-generation project utilizes methane gas, a by-product of the anaerobic digestion process, to generate both electricity and heat that is used at the plant. The SDCSID calculated that at the current anaerobic gas production rate, a 140 KW engine generator could be run almost 24 hours a day. Approximately 75% of the current electrical needs at the North Plant are supplied by the 140 KW engine generator. Also, all of the heat necessary to raise the temperature of the incoming sludge to 95{degrees}F, and to heat four large buildings is supplied from the heat recovery system of the engine. The system utilizes an induction type generator to supply electricity, which is somewhat simpler to design and less expensive to install than a synchronous type system. An induction system utilizes the Electrical Utility`s incoming power to excite the generator to correct the phase so that is can be used by the loads in the plant. In addition, the SDCSID installed a second identical engine generator as a back-up and to peak shave. Plant effluent is used to cool the engines instead of air-cooling through radiators.

  1. Identifying best practice in relation to Iodine-131 ablation discharges to sewers in Ireland

    International Nuclear Information System (INIS)

    Ryan, Thomas P.; Fennell, Stepehn; McGarry, Ann; Punt, Adrian

    2008-01-01

    Full text: In line with a commitment in Ireland's strategy on the implementation of the Oslo-Paris Convention (OSPAR) as well as recent developments in the provision of national oncology services, best practice in relation to Iodine-131 (I-131) ablation discharges to sewers in Ireland is under review. Preparatory to this review the Radiological Protection Institute of Ireland (RPII) commissioned a study of current practices in Ireland and associated doses as well as a review of international best practice and advice. Currently, there are three hospitals in Ireland at which thyroid ablation therapy procedures (large therapeutic administrations of I-131 for thyroid cancer treatment) are carried out. Only one facility has a limited capacity for delay and decay storage prior to discharge. Based on current administrations and discharges, the potentially most exposed workers comprises hospital plumbers dealing with specific incidents with estimated doses in the order of 50 to 70 μSv per incident. Doses to sewage workers and fishing communities are estimated at less than 4 μSv y -1 and 0.4 μSv y -1 respectively. Based on anticipated future service requirements in Ireland, a marginal increase in doses to some of these groups is estimated. Iodine-131 discharges to the environment and associated doses to workers and members of the public may be significantly reduced by the introduction of state-of-the-art delay and decay tanks using multi-tank vacuum systems. The justification for the introduction of a regulatory requirement to install such systems is examined taking account of: discharges to the environment, concentrations in the environment, doses to workers and members of the public, best available techniques (BAT), international best practice and advice as well as the financial implications for medical facilities. The case for retrofitting delay and decay tanks to existing medical facilities is also examined as well as the option of including such tanks in the

  2. Climate change impacts on the duration and frequency of combined sewer overflows

    Science.gov (United States)

    Fortier, C.; Mailhot, A.

    2012-12-01

    Combined sewer overflows (CSO) occur when large rainwater inflow from heavy precipitation exceeds the capacity of urban combined sewage systems. Many American and European cities with old sewage systems see their water quality significantly deteriorate during such events. In the long term, changes in the rainfall regime due to climate change may lead to more severe and more frequent CSO episodes and thus compel cities to review their global water management. The overall objective of this study is to investigate how climate change will impact CSO frequency and duration. Data from rain gauges located nearby 30 overflow outfalls, in southern Quebec, Canada, were used to identify rain events leading to overflows, using CSO monitored data from May to October during the period 2007-2009. For each site, occurrence and duration of CSO events were recorded and linked to a rainfall event. Many rain events features can be used to predict CSO events, such as total depth, duration, average intensity and peak intensity. Results based on Pearson product-moment correlation coefficients and multiple regression analysis show that CSO occurrence is best predicted by total rainfall. A methodology is proposed to calculate the CSO probability of occurrence and duration for each site of interest using rainfall series as input data. Monte Carlo method is then used to estimate CSO frequency. To evaluate the climate change impact on CSO, these relationships are used with simulated data from the Canadian Regional Climate Model to compare the distribution of annual number of CSO events over the 1960-1990 period and the 2070-2100 period.

  3. Risk-based decision making to manage water quality failures caused by combined sewer overflows

    Science.gov (United States)

    Sriwastava, A. K.; Torres-Matallana, J. A.; Tait, S.; Schellart, A.

    2017-12-01

    Regulatory authorities set certain environmental permit for water utilities such that the combined sewer overflows (CSO) managed by these companies conform to the regulations. These utility companies face the risk of paying penalty or negative publicity in case they breach the environmental permit. These risks can be addressed by designing appropriate solutions such as investing in additional infrastructure which improve the system capacity and reduce the impact of CSO spills. The performance of these solutions is often estimated using urban drainage models. Hence, any uncertainty in these models can have a significant effect on the decision making process. This study outlines a risk-based decision making approach to address water quality failure caused by CSO spills. A calibrated lumped urban drainage model is used to simulate CSO spill quality in Haute-Sûre catchment in Luxembourg. Uncertainty in rainfall and model parameters is propagated through Monte Carlo simulations to quantify uncertainty in the concentration of ammonia in the CSO spill. A combination of decision alternatives such as the construction of a storage tank at the CSO and the reduction in the flow contribution of catchment surfaces are selected as planning measures to avoid the water quality failure. Failure is defined as exceedance of a concentration-duration based threshold based on Austrian emission standards for ammonia (De Toffol, 2006) with a certain frequency. For each decision alternative, uncertainty quantification results into a probability distribution of the number of annual CSO spill events which exceed the threshold. For each alternative, a buffered failure probability as defined in Rockafellar & Royset (2010), is estimated. Buffered failure probability (pbf) is a conservative estimate of failure probability (pf), however, unlike failure probability, it includes information about the upper tail of the distribution. A pareto-optimal set of solutions is obtained by performing mean

  4. Increases of equatorial total electron content (TEC) during magnetic storms

    International Nuclear Information System (INIS)

    Yeboah-Amankwah, D.

    1976-01-01

    This paper is a report on the analysis of equatorial electron content, TEC, during magnetic storms. Storms between 1969 and 1972 have been examined as part of an on-going study of TEC morphology during magnetically disturbed days. The published magnetic Ksup(p) indices and TEC data from the Legon abservatory have been employed. The general picture arising from the analysis is that the total electron content of the ionosphere is significantly enhanced during magnetic storms. (author)

  5. What does the magnetic storm development depend on?

    International Nuclear Information System (INIS)

    Wodnicka, E.B.

    1991-01-01

    Adiabatic drift model applied to the magnetic storm development simulation reveals the significance of initial energy, initial pitch angle and the site of ions injection for the intensity, growth time and growth rate of a storm produced by two ion species - H + and O + . The most severe storms are caused by the ring current intensified by low initial pitch angle ions injected at low radial distance in the postmidnight local time region. (author)

  6. Runoff Modelling in Urban Storm Drainage by Neural Networks

    DEFF Research Database (Denmark)

    Rasmussen, Michael R.; Brorsen, Michael; Schaarup-Jensen, Kjeld

    1995-01-01

    A neural network is used to simulate folw and water levels in a sewer system. The calibration of th neural network is based on a few measured events and the network is validated against measureed events as well as flow simulated with the MOUSE model (Lindberg and Joergensen, 1986). The neural...... network is used to compute flow or water level at selected points in the sewer system, and to forecast the flow from a small residential area. The main advantages of the neural network are the build-in self calibration procedure and high speed performance, but the neural network cannot be used to extract...... knowledge of the runoff process. The neural network was found to simulate 150 times faster than e.g. the MOUSE model....

  7. Online monitoring and conditional regression tree test: Useful tools for a better understanding of combined sewer network behavior.

    Science.gov (United States)

    Bersinger, T; Bareille, G; Pigot, T; Bru, N; Le Hécho, I

    2018-06-01

    A good knowledge of the dynamic of pollutant concentration and flux in a combined sewer network is necessary when considering solutions to limit the pollutants discharged by combined sewer overflow (CSO) into receiving water during wet weather. Identification of the parameters that influence pollutant concentration and flux is important. Nevertheless, few studies have obtained satisfactory results for the identification of these parameters using statistical tools. Thus, this work uses a large database of rain events (116 over one year) obtained via continuous measurement of rainfall, discharge flow and chemical oxygen demand (COD) estimated using online turbidity for the identification of these parameters. We carried out a statistical study of the parameters influencing the maximum COD concentration, the discharge flow and the discharge COD flux. In this study a new test was used that has never been used in this field: the conditional regression tree test. We have demonstrated that the antecedent dry weather period, the rain event average intensity and the flow before the event are the three main factors influencing the maximum COD concentration during a rainfall event. Regarding the discharge flow, it is mainly influenced by the overall rainfall height but not by the maximum rainfall intensity. Finally, COD discharge flux is influenced by the discharge volume and the maximum COD concentration. Regression trees seem much more appropriate than common tests like PCA and PLS for this type of study as they take into account the thresholds and cumulative effects of various parameters as a function of the target variable. These results could help to improve sewer and CSO management in order to decrease the discharge of pollutants into receiving waters. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Consequential environmental and economic life cycle assessment of green and gray stormwater infrastructures for combined sewer systems.

    Science.gov (United States)

    Wang, Ranran; Eckelman, Matthew J; Zimmerman, Julie B

    2013-10-01

    A consequential life cycle assessment (LCA) is conducted to evaluate the trade-offs between water quality improvements and the incremental climate, resource, and economic costs of implementing green (bioretention basin, green roof, and permeable pavement) versus gray (municipal separate stormwater sewer systems, MS4) alternatives of stormwater infrastructure expansions against a baseline combined sewer system with combined sewer overflows in a typical Northeast US watershed for typical, dry, and wet years. Results show that bioretention basins can achieve water quality improvement goals (e.g., mitigating freshwater eutrophication) for the least climate and economic costs of 61 kg CO2 eq. and $98 per kg P eq. reduction, respectively. MS4 demonstrates the minimum life cycle fossil energy use of 42 kg oil eq. per kg P eq. reduction. When integrated with the expansion in stormwater infrastructure, implementation of advanced wastewater treatment processes can further reduce the impact of stormwater runoff on aquatic environment at a minimal environmental cost (77 kg CO2 eq. per kg P eq. reduction), which provides support and valuable insights for the further development of integrated management of stormwater and wastewater. The consideration of critical model parameters (i.e., precipitation intensity, land imperviousness, and infrastructure life expectancy) highlighted the importance and implications of varying local conditions and infrastructure characteristics on the costs and benefits of stormwater management. Of particular note is that the impact of MS4 on the local aquatic environment is highly dependent on local runoff quality indicating that a combined system of green infrastructure prior to MS4 potentially provides a more cost-effective improvement to local water quality.

  9. Dynamic interactions between coastal storms and salt marshes: A review

    Science.gov (United States)

    Leonardi, Nicoletta; Carnacina, Iacopo; Donatelli, Carmine; Ganju, Neil K.; Plater, Andrew James; Schuerch, Mark; Temmerman, Stijn

    2018-01-01

    This manuscript reviews the progresses made in the understanding of the dynamic interactions between coastal storms and salt marshes, including the dissipation of extreme water levels and wind waves across marsh surfaces, the geomorphic impact of storms on salt marshes, the preservation of hurricanes signals and deposits into the sedimentary records, and the importance of storms for the long term survival of salt marshes to sea level rise. A review of weaknesses, and strengths of coastal defences incorporating the use of salt marshes including natural, and hybrid infrastructures in comparison to standard built solutions is then presented.Salt marshes are effective in dissipating wave energy, and storm surges, especially when the marsh is highly elevated, and continuous. This buffering action reduces for storms lasting more than one day. Storm surge attenuation rates range from 1.7 to 25 cm/km depending on marsh and storms characteristics. In terms of vegetation properties, the more flexible stems tend to flatten during powerful storms, and to dissipate less energy but they are also more resilient to structural damage, and their flattening helps to protect the marsh surface from erosion, while stiff plants tend to break, and could increase the turbulence level and the scour. From a morphological point of view, salt marshes are generally able to withstand violent storms without collapsing, and violent storms are responsible for only a small portion of the long term marsh erosion.Our considerations highlight the necessity to focus on the indirect long term impact that large storms exerts on the whole marsh complex rather than on sole after-storm periods. The morphological consequences of storms, even if not dramatic, might in fact influence the response of the system to normal weather conditions during following inter-storm periods. For instance, storms can cause tidal flats deepening which in turn promotes wave energy propagation, and exerts a long term

  10. Dynamic interactions between coastal storms and salt marshes: A review

    Science.gov (United States)

    Leonardi, Nicoletta; Carnacina, Iacopo; Donatelli, Carmine; Ganju, Neil Kamal; Plater, Andrew James; Schuerch, Mark; Temmerman, Stijn

    2018-01-01

    This manuscript reviews the progresses made in the understanding of the dynamic interactions between coastal storms and salt marshes, including the dissipation of extreme water levels and wind waves across marsh surfaces, the geomorphic impact of storms on salt marshes, the preservation of hurricanes signals and deposits into the sedimentary records, and the importance of storms for the long term survival of salt marshes to sea level rise. A review of weaknesses, and strengths of coastal defences incorporating the use of salt marshes including natural, and hybrid infrastructures in comparison to standard built solutions is then presented. Salt marshes are effective in dissipating wave energy, and storm surges, especially when the marsh is highly elevated, and continuous. This buffering action reduces for storms lasting more than one day. Storm surge attenuation rates range from 1.7 to 25 cm/km depending on marsh and storms characteristics. In terms of vegetation properties, the more flexible stems tend to flatten during powerful storms, and to dissipate less energy but they are also more resilient to structural damage, and their flattening helps to protect the marsh surface from erosion, while stiff plants tend to break, and could increase the turbulence level and the scour. From a morphological point of view, salt marshes are generally able to withstand violent storms without collapsing, and violent storms are responsible for only a small portion of the long term marsh erosion. Our considerations highlight the necessity to focus on the indirect long term impact that large storms exerts on the whole marsh complex rather than on sole after-storm periods. The morphological consequences of storms, even if not dramatic, might in fact influence the response of the system to normal weather conditions during following inter-storm periods. For instance, storms can cause tidal flats deepening which in turn promotes wave energy propagation, and exerts a long term detrimental

  11. Hindcasting of storm waves using neural networks

    Digital Repository Service at National Institute of Oceanography (India)

    Rao, S.; Mandal, S.

    Department NN neural network net i weighted sum of the inputs of neuron i o k network output at kth output node P total number of training pattern s i output of neuron i t k target output at kth output node 1. Introduction Severe storms occur in Bay of Bengal...), forecasting of runoff (Crespo and Mora, 1993), concrete strength (Kasperkiewicz et al., 1995). The uses of neural network in the coastal the wave conditions will change from year to year, thus a proper statistical and climatological treatment requires several...

  12. Space storms and radiation causes and effects

    CERN Document Server

    Schrijver, Carolus J

    2010-01-01

    Heliophysics is a fast-developing scientific discipline that integrates studies of the Sun's variability, the surrounding heliosphere, and the environment and climate of planets. The Sun is a magnetically variable star and for planets with intrinsic magnetic fields, planets with atmospheres, or planets like Earth with both, there are profound consequences. This 2010 volume, the second in this series of three heliophysics texts, integrates the many aspects of space storms and the energetic radiation associated with them - from causes on the Sun to effects in planetary environments. It reviews t

  13. Elementary composition in sediments of rivers located near to the dumps of domestic sewers by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Oliveira, Helder de; Mortatti, Jefferson; Bendassolli, Jose A.; Trivelin, Paulo C.O.; Santana, Andre G.B.

    2000-01-01

    Had to the fact of sediments to be important metal loaders weighed in the hydro cycle, it was inquired anthropogenic contribution of pollution during the passage of the river Piracicaba in the city of Piracicaba, Sao Paulo. Samples of sediments had been collected, during and posterior before to the urban perimeter of the city, next the dumps to domestic sewers without any handling, the open sky. With this study, it was possible to identify elements with evidence of anthropogenic enrichment in the river. The Cr was the element that had the biggest anthropogenic contribution during its passage in the city. (author)

  14. Characterization and risk assessment of seasonal and weather dynamics in organic pollutant mixtures from discharge of a separate sewer system.

    Science.gov (United States)

    Beckers, Liza-Marie; Busch, Wibke; Krauss, Martin; Schulze, Tobias; Brack, Werner

    2018-05-15

    Sites of wastewater discharge are hotspots for pollution of freshwaters with organic micropollutants and are often associated with adverse effects to aquatic organisms. The assessment, monitoring and managment of these hotspots is challenged by variations in the pollutant mixture composition due to season, weather conditions and random spills. In this study, we unraveled temporal exposure patterns in organic micropollutant mixtures from wastewater discharge and analyzed respective acute and sublethal risks for aquatic organisms. Samples were taken from two components of a separate sewer system i) a wastewater treatment plant (WWTP) and ii) a rain sewer of a medium size town as well as from the receiving river in different seasons. Rain sewer samples were separately collected for rain and dry - weather conditions. We analyzed 149 compounds by liquid chromatography-tandem mass spectrometry (LC-MS/MS). By considering the pollution dynamics in the point sources, we reduced the complexity of pollutant mixtures by k-means clustering to a few emission groups representing temporal and weather-related pollution patterns. From these groups, we derived biological quality element (BQE) - specific risk patterns. In most cases, one main risk driving emission group and a few individual risk driving compounds were identified for each BQE. While acute risk for fish was quite low, algae were exposed to seasonally emitted herbicides (terbuthylazine, spiroxamine) and crustaceans to randomly spilled insecticides (diazinon, dimethoate). Sublethal risks for all BQE were strongly influenced by constantly emitted pollutants, above all, pharmaceuticals. Variability of risks in the river was mainly driven by water discharge of the river rather than by season or peak events. Overall, the studied WWTP represented the major pollution source with a specific emission of agricultural compounds. However, the investigated rain sewer showed to be a constant pollution source due to illicit connections

  15. Correlations between rainfall data and insurance damage data related to sewer flooding for the case of Aarhus, Denmark

    DEFF Research Database (Denmark)

    Spekkers, Matthieu; Zhou, Qianqian; Arnbjerg-Nielsen, Karsten

    Sewer flooding due to extreme rainfall may result in considerable damage. Damage data to quantify costs of cleaning, drying, and replacing materials and goods are rare in literature. In this study, insurance claim data related to property damages were analysed for the municipality of Aarhus...... to underestimations of correlations between rainfall and damage variables. Rainfall data from two rain gauges were used to extract rainfall characteristics. From cross correlations between time series of rainfall and claim data, it can be concluded that rainfall events induce claims mostly on the same day, but also...

  16. Modelling the impact of retention–detention units on sewer surcharge and peak and annual runoff reduction

    DEFF Research Database (Denmark)

    Locatelli, Luca; Gabriel, S.; Mark, O.

    2015-01-01

    . The impact of retrofitting a retention-detention unit of 3.3 m(3)/100 m(2) (volume/impervious area) was simulated for a small catchment in Copenhagen using MIKE URBAN. The retention-detention unit was shown to prevent flooding from the sewer for a 10-year rainfall event. Statistical analysis of continuous...... simulations covering 22 years showed that annual stormwater runoff was reduced by 68-87%, and that the retention volume was on average 53% full at the beginning of rain events. The effect of different retention-detention volume combinations was simulated, and results showed that allocating 20...

  17. Weathering the storm: Improving therapeutic interventions for cytokine storm syndromes by targeting disease pathogenesis.

    Science.gov (United States)

    Weaver, Lehn K; Behrens, Edward M

    2017-03-01

    Cytokine storm syndromes require rapid diagnosis and treatment to limit the morbidity and mortality caused by the hyperinflammatory state that characterizes these devastating conditions. Herein, we discuss the current knowledge that guides our therapeutic decision-making and personalization of treatment for patients with cytokine storm syndromes. Firstly, ICU-level supportive care is often required to stabilize patients with fulminant disease while additional diagnostic evaluations proceed to determine the underlying cause of cytokine storm. Pharmacologic interventions should be focused on removing the inciting trigger of inflammation and initiation of an individualized immunosuppressive regimen when immune activation is central to the underlying disease pathophysiology. Monitoring for a clinical response is required to ensure that changes in the therapeutic regimen can be made as clinically warranted. Escalation of immunosuppression may be required if patients respond poorly to the initial therapeutic interventions, while a slow wean of immunosuppression in patients who improve can limit medication-related toxicities. In certain scenarios, a decision must be made whether an individual patient requires hematopoietic cell transplantation to prevent recurrence of disease. Despite these interventions, significant morbidity and mortality remains for cytokine storm patients. Therefore, we use this review to propose a clinical schema to guide current and future attempts to design rational therapeutic interventions for patients suffering from these devastating conditions, which we believe speeds the diagnosis of disease, limits medication-related toxicities, and improves clinical outcomes by targeting the heterogeneous and dynamic mechanisms driving disease in each individual patient.

  18. From pre-storm activity to magnetic storms: a transition described in terms of fractal dynamics

    Directory of Open Access Journals (Sweden)

    G. Balasis

    2006-12-01

    Full Text Available We show that distinct changes in scaling parameters of the Dst index time series occur as an intense magnetic storm approaches, revealing a gradual reduction in complexity. The remarkable acceleration of energy release – manifested in the increase in susceptibility – couples to the transition from anti-persistent (negative feedback to persistent (positive feedback behavior and indicates that the occurence of an intense magnetic storm is imminent. The main driver of the Dst index, the VBSouth electric field component, does not reveal a similar transition to persistency prior to the storm. This indicates that while the magnetosphere is mostly driven by the solar wind the critical feature of persistency in the magnetosphere is the result of a combination of solar wind and internal magnetospheric activity rather than solar wind variations alone. Our results suggest that the development of an intense magnetic storm can be studied in terms of "intermittent criticality" that is of a more general character than the classical self-organized criticality phenomena, implying the predictability of the magnetosphere.

  19. Lightning Evolution In Two North Central Florida Summer Multicell Storms and Three Winter/Spring Frontal Storms

    Science.gov (United States)

    Caicedo, J. A.; Uman, M. A.; Pilkey, J. T.

    2018-01-01

    We present the first lightning evolution studies, via the Lightning Mapping Array (LMA) and radar, performed in North Central Florida. Parts of three winter/spring frontal storms (cold season) and two complete summer (warm season) multicell storms are studied. Storm parameters measured are as follows: total number of flashes, flash-type classification, first flashes, flash initiation altitude, flash initiation power, flash rate (flashes per minute), charge structure, altitude and temperature ranges of the inferred charge regions, atmospheric isotherm altitude, radar base reflectivity (dBZ), and radar echo tops (EET). Several differences were found between summer multicell and winter/spring frontal storms in North Central Florida: (1) in winter/spring storms, the range of altitudes that all charge regions occupy is up to 1 km lower in altitude than in summer storms, as are the 0°C, -10°C, and -20°C isotherms; (2) lightning activity in summer storms is highly correlated with changes in radar signatures, in particular, echo tops; and (3) the LMA average initiation power of all flash types in winter/frontal storms is about an order of magnitude larger than that for summer storms. In relation to storms in other geographical locations, North Central Florida seasonal storms were found to have similarities in most parameters studied with a few differences, examples in Florida being (1) colder initiation altitudes for intracloud flashes, (2) charge regions occupying larger ranges of atmospheric temperatures, and (3) winter/spring frontal storms not having much lightning activity in the stratiform region.

  20. Network Intrusion Detection System using Apache Storm

    Directory of Open Access Journals (Sweden)

    Muhammad Asif Manzoor

    2017-06-01

    Full Text Available Network security implements various strategies for the identification and prevention of security breaches. Network intrusion detection is a critical component of network management for security, quality of service and other purposes. These systems allow early detection of network intrusion and malicious activities; so that the Network Security infrastructure can react to mitigate these threats. Various systems are proposed to enhance the network security. We are proposing to use anomaly based network intrusion detection system in this work. Anomaly based intrusion detection system can identify the new network threats. We also propose to use Real-time Big Data Stream Processing Framework, Apache Storm, for the implementation of network intrusion detection system. Apache Storm can help to manage the network traffic which is generated at enormous speed and size and the network traffic speed and size is constantly increasing. We have used Support Vector Machine in this work. We use Knowledge Discovery and Data Mining 1999 (KDD’99 dataset to test and evaluate our proposed solution.