WorldWideScience

Sample records for stored energy thermoluminescence

  1. Thermal annealing of high dose radiation induced damage at room temperature in alkaline. Stored energy, thermoluminescence and coloration

    International Nuclear Information System (INIS)

    Delgado, L.

    1980-01-01

    The possible relation between stored energy, thermoluminescence and colour centre annealing in gamma and electron irradiated alkali halides is studied. Thermoluminescence occurs at temperature higher than the temperature at which the main stored energy peak appears. No stored energy release is detected in additively coloured KC1 samples. Plastic deformation and doping with Ca and Sr induce a stored energy spectrum different from the spectrum observed in pure and as cleaved samples, but the amount of stored energy does not change for a given irradiation dose.Capacity of alkali halides to store energy by irradiation increases as the cation size decreases. (Author) 51 refs

  2. Thermal annealing of high dose radiation induced damage at room temperature in alkaline. Stored energy, thermoluminescence and coloration; Aniquilacion termica de dano inducido por irradiacion a altas dosis en haluros alcalinos a 300 k. energia almacenda. Termoluminiscencia y coloracion

    Energy Technology Data Exchange (ETDEWEB)

    Delgado, L

    1980-07-01

    The possible relation between stored energy, thermoluminescence and colour centre annealing in gamma and electron irradiated alkali halides is studied. Thermoluminescence occurs at temperature higher than the temperature at which the main stored energy peak appears. No stored energy release is detected in additively coloured KC1 samples. Plastic deformation and doping with Ca and Sr induce a stored energy spectrum different from the spectrum observed in pure and as cleaved samples, but the amount of stored energy does not change for a given irradiation dose.Capacity of alkali halides to store energy by irradiation increases as the cation size decreases. (Author) 51 refs.

  3. Distributed energy store railgun

    International Nuclear Information System (INIS)

    Marshall, R.A.

    1991-01-01

    This paper reports that when the limiting case of a distributed energy store railgun is analyzed, i.e., the case where the space between adjacent energy stores become indefinitely small, three important results are obtained. First, the shape of the current pulse delivered by each store is sinusoidal and an exponential tail. Second, the rail-to-rail voltage behind the rear-most active store approaches zero. Third, it is not possible to choose parameters in such a way that capacitor crowbars can be eliminated

  4. Superconducting energy store

    International Nuclear Information System (INIS)

    Elsel, W.

    1986-01-01

    The advantages obtained by the energy store device according to the invention with a superconducting solenoid system consist of the fact that only relatively short superconducting forward and return leads are required, which are collected into cables as far as possible. This limits the coolant losses of the cables. Only one relatively expensive connecting part with a transition of its conductors from room temperature to a low temperature is required, which, like the normal conducting current switch, is easily accessible. As the continuation has to be cooled independently of the upper part solenoid, cooling of this continuation part can prevent the introduction of large quantities of heat into the connected part solenoid. Due to the cooling of the forward and return conductors of the connecting cable with the coolant of the lower part solenoid, there are relatively few separations between the coolant spaces of the part solenoids. (orig./MM) [de

  5. Thermoluminescence dating method

    International Nuclear Information System (INIS)

    Zink, A.

    2004-01-01

    A crystal that is submitted to radiation stores energy and releases this energy under the form of light whenever it is heated. These 2 properties: the ability to store energy and the ability to reset the energy stored are the pillars on which time dating methods like thermoluminescence are based. A typical accuracy of the thermoluminescence method is between 5 to 7% but an accuracy of 3% can be reached with a sufficient number of measurement. This article describes the application of thermoluminescence to the dating of a series of old terra-cotta statues. This time measurement is absolute and does not require any calibration, it represents the time elapsed since the last heating of the artifact. (A.C.)

  6. A Dual Function Energy Store

    Directory of Open Access Journals (Sweden)

    Ron Tolmie

    2014-11-01

    Full Text Available Heat can be collected from local energy sources and concentrated into a relatively small volume, and at a useful working temperature, by using a heat pump as the concentrator. That heat can be stored and utilized at a later date for applications like space heating. The process is doing two things at the same time: storing heat and shifting the power demand. The concentration step can be done at night when there is normally a surplus of power and its timing can be directly controlled by the power grid operator to ensure that the power consumption occurs only when adequate power is available. The sources of heat can be the summer air, the heat extracted from buildings by their cooling systems, natural heat from the ground or solar heat, all of which are free, abundant and readily accessible. Such systems can meet the thermal needs of buildings while at the same time stabilizing the grid power demand, thus reducing the need for using fossil-fuelled peaking power generators. The heat pump maintains the temperature of the periphery at the ambient ground temperature so very little energy is lost during storage.

  7. Distributed energy store railguns experiment and analysis

    International Nuclear Information System (INIS)

    Holland, L.D.

    1984-01-01

    Electromagnetic acceleration of projectiles holds the potential for achieving higher velocities than yet achieved by any other means. A railgun is the simplest form of electromagnetic macroparticle accelerator and can generate the highest sustained accelerating force. The practical length of conventional railguns is limited by the impedance of the rails because current must be carried along the entire length of the rails. A railgun and power supply system called the distributed energy store railgun was proposed as a solution to this limitation. The distributed energy store railgun used multiple current sources connected to the rails of a railgun at points distributed along the bore. These current sources (energy stores) are turned on in sequence as the projectile moves down the bore so that current is fed to the railgun from behind the armature. In this system the length of the rails that carry the full armature current is less than the total length of the railgun. If a sufficient number of energy stores is used, this removes the limitation on the length of a railgun. An additional feature of distributed energy store type railguns is that they can be designed to maintain a constant pressure on the projectile being accelerated. A distributed energy store railgun was constructed and successfully operated. In addition to this first demonstration of the distributed energy store railgun principle, a theoretical model of the system was also constructed

  8. Stored energy in irradiated silicon carbide

    Energy Technology Data Exchange (ETDEWEB)

    Snead, L.L.; Burchell, T.D. [Oak Ridge National Lab., TN (United States)

    1997-04-01

    This report presents a short review of the phenomenon of Wigner stored energy release from irradiated graphite and discusses it in relation to neutron irradiation of silicon carbide. A single published work in the area of stored energy release in SiC is reviewed and the results are discussed. It appears from this previous work that because the combination of the comparatively high specific heat of SiC and distribution in activation energies for recombining defects, the stored energy release of SiC should only be a problem at temperatures lower than those considered for fusion devices. The conclusion of this preliminary review is that the stored energy release in SiC will not be sufficient to cause catastrophic heating in fusion reactor components, though further study would be desirable.

  9. Battery Technology Stores Clean Energy

    Science.gov (United States)

    2008-01-01

    Headquartered in Fremont, California, Deeya Energy Inc. is now bringing its flow batteries to commercial customers around the world after working with former Marshall Space Flight Center scientist, Lawrence Thaller. Deeya's liquid-cell batteries have higher power capability than Thaller's original design, are less expensive than lead-acid batteries, are a clean energy alternative, and are 10 to 20 times less expensive than nickel-metal hydride batteries, lithium-ion batteries, and fuel cell options.

  10. Thermoluminescent analyses of mean photon energy of a field

    Energy Technology Data Exchange (ETDEWEB)

    Cavalieri, T. A.; De Paiva, F.; Fonseca, G.; Dalledone S, P. de T.; Yoriyaz, H., E-mail: tassio.cavalieri@usp.br [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    Nowadays a common method of dosimetry is utilize the thermoluminescent dosimetry (TLD) of LiF, where for pure gamma field is typically used the LiF or CaF{sub 2} TLDs and for mixed neutron and gamma field dosimetry is used the pair TLD-600/TLD-700. The difference between these three LiF TLDs is the amount of isotope {sup 6}Li in their composition. The isotope {sup 6}Li has a great cross section for thermal neutrons, making the TLD-600 sensitive to thermal neutrons beyond the radiation gamma. Whereas the TLD-700 is considered sensitive only for radiation gamma. Some studies showed an energetic dependence of these TLDs for gammas rays. So the goal of this work was study these energetic dependence of TLDs from the angular coefficient of their response versus dose calibration curves when they were irradiated in four fields with photons of different energies: 43 keV, 662 keV, 1.2 MeV, 3 MeV. In order to create the calibration curves TLD, it was performed three irradiations with distinct exposure times for each photon energy. These studies showed a different angular coefficient to each curve; demonstrate the energetic dependence of these TLDs. By simulation with Monte Carlo based code, MCNP-5, it was observed the deposited photon dose due to different photons energies. From these simulations, it was also possible to observe a difference of dose deposition in TLDs when they were exposed to the same dose provided from different photons energies. These work showed the previously study of photon energetic dependence of LiF TLDs. (Author)

  11. Thermoluminescence dating

    International Nuclear Information System (INIS)

    Price, D.M.

    1999-01-01

    Thermoluminescence (TL) dating of sediments depends upon the acquisition and long term stable storage of TL energy by crystalline minerals contained within a sedimentary unit. This energy is stored in the form of trapped electrons and quartz sand is the most commonly used mineral employed in the dating process. Prior to the final depositional episode it is necessary that any previously acquired TL is removed by exposure to sunlight. After burial the TL begins to build up again at a rate dependent upon the radiation flux delivered by long-lived isotopes of uranium, thorium and potassium. The presence of rubidium and cosmic radiation generally play a lesser but contributory roll, and the total radiation dose delivered to the TL phosphor is modified by the presence of water. The period since deposition is therefore measured by determining the total amount of stored TL energy, the palaeodose (P), and the rate at which this energy is acquired, the annual radiation dose (ARD). TL dating may be applied to eolian, fluvial, coastal and in some cases, marine sediments. the technique is also successfully applied to volcanic materials and to a certain extent to archeological specimens

  12. Stored energy recovery of irradiated copper

    International Nuclear Information System (INIS)

    Richard, R.T.; Chaplin, R.L.; Coltman, R.R. Jr.; Kerchner, H.R.; Klabunde, C.E.

    1990-01-01

    The stored energy released in Stage I recovery of reactor neutron irradiated copper was measured by differential thermal analysis calorimetry for three fluences up to a maximum of 3.5 x 10 18 n/cm 2 (E>0.1 MeV) after irradiation at temperatures of less than 10 K. The dependence of the stored energy upon fluence, and a tendency toward saturation, were observed. Theoretical reaction rate processes were compared directly with the experimental rates of stored energy release, and the parameters associated with the theory were compared with results from previous resistivity measurements. Good agreement was found for several parameters, but major differences with previous D + E substage results lead to the conclusion that the point defect model may not describe materials experiencing severe neutron damage. Computer studies of warmup rates were made for first and second order and for correlated recovery processes as a function of defect concentration and of external power input. First and second order processes show definite distortion in their recovery rate curves for high defect concentrations; the correlated recovery process shows a much less pronounced effect. This investigation of stored energy used several new approaches. The use of induced radioactivity within the sample as the heating source, and the use of computer generated theoretical stored energy release curves to analyze the data were unique. (author)

  13. Energy absorption buildup factors for thermoluminescent dosimetric materials and their tissue equivalence

    DEFF Research Database (Denmark)

    Manohara, S.R.; Hanagodimath, S.M.; Gerward, Leif

    2010-01-01

    Gamma ray energy-absorption buildup factors were computed using the five-parameter geometric progression (G-P) fitting formula for seven thermoluminescent dosimetric (TLD) materials in the energy range 0.015-15 MeV, and for penetration depths up to 40 mfp (mean free path). The generated energy-absorption...

  14. Charge and Energy Stored in a Capacitor

    Science.gov (United States)

    Kraftmakher, Yaakov

    2012-01-01

    Using a data-acquisition system, the charge and energy stored in a capacitor are measured and displayed during the charging/discharging process. The experiment is usable as a laboratory work and/or a lecture demonstration. (Contains 3 figures.)

  15. Energy stored in irradiated NaCl

    International Nuclear Information System (INIS)

    Lidiard, A.B.

    1979-01-01

    Recently reported measurements of the energy stored in heavily irradiated NaCl are reviewed in the light of recent understanding of radiation-damage processes in this material. It is shown that, in the ranges of temperatures and dose rates of these experiments, the F-centres produced by the irradiation are retained principally in the form of colloids: the stored energy is thus a direct measure of the number of F-centres retained in this form. Comparison of these results with the prediction of the recently proposed theory of colloid growth shows that the predictions of the dependence of colloid growth rates upon temperature and dose rate are qualitatively correct. The dependence of stored energy dose, however, appears to require the inclusion of a thermally activated back-reaction and possible modifications to the theory are briefly discussed. However, further experiments in this range of temperatures and dose rates are necessary for more quantitative tests of the theory. This reconsideration of the data does not alter the broad conclusion as to the relative insignificance of stored energy in a natural salt formation used as a radioactive waste repository, although more extensive measurements permitting a more exact test of theory would allow better predictions to be made for such applications. (author)

  16. Experimental verification of stored energy calculations

    International Nuclear Information System (INIS)

    Hann, C.R.; Christensen, J.A.; Lanning, D.D.; Marshall, R.K.; Williford, R.E.

    1975-01-01

    A description is provided of irradiation tests designed to provide data needed to verify existing steady state fuel performance codes. The tests are being conducted in the Halden Reactor, and are designed to provide data pertinent to stored energy calculations over a range of linear heat ratings utilized in contemporary power reactors

  17. Distributed energy store railguns experiment and analysis

    Science.gov (United States)

    Holland, L. D.

    1984-02-01

    Electromagnetic acceleration of projectiles holds the potential for achieving higher velocities than yet achieved by any other means. A railgun is the simplest form of electromagnetic macroparticle accelerator and can generate the highest sustained accelerating force. The practical length of conventional railguns is limited by the impedance of the rails because current must be carried along the entire length of the rails. A railgun and power supply system called the distributed energy store railgun was proposed as a solution to this limitation. A distributed energy storage railgun was constructed and successfully operated. In addition to this demonstration of the distributed energy store railgun principle, a theoretical model of the system was also constructed. A simple simulation of the railgun system based on this model, but ignoring frictional drag, was compared with the experimental results. During the process of comparing results from the simulation and the experiment, the effect of significant frictional drag of the projectile on the sidewalls of the bore was observed.

  18. Fast liberation of energy stored using superconductors

    International Nuclear Information System (INIS)

    Prost, G.; Sole, J.

    1967-01-01

    After a rapid description of the circumstances in which they first thought of using superconducting materials for the storage and liberation of energy, the authors examine, in comparison to condensers, the energy densities which can thus be stored, the methods used for introducing this energy into the superconducting circuit and for trapping it, and the law governing the discharge of this energy into a purely dissipative impedance. This leads to a derivation of the expression for the energy yield which depends on the characteristics of the switch used for opening the superconducting circuit. An experimental study has been made of a superconducting switch with a view to understanding the various parameters. As a result of this analysis, transitions of this switch, over the whole of its mass, were obtained for periods of a few microseconds, and energy yields close to unity were obtained. The obtention of fast discharges is now no longer a technological problem. (authors) [fr

  19. Thermoluminescence - physics and applications

    International Nuclear Information System (INIS)

    Sunta, C.M.

    1992-01-01

    The interaction of ionizing radiations with matter leads to various effects, some of which leave memory in the target material. These memory effects can be seen as the after-effects of the irradiation. Thermoluminescence is one such phenomenon in the insulating solids. This paper describes the sequence of the physical events beginning with the incidence of an ionizing particle, leading to a trail of atomic and electronic displacements which stabilize in the form of so called defect centres. These defects - interstitials, colour centres, etc., store energy in their configuration. Most of the damage effects are reversible. The return of the displaced entities to their original site leads to the release of the stored energy. Thermoluminescence is the result of the re-adjustment (relaxation) of the displaced electrons. The stimulation for the relaxation process is provided by heating of the irradiated sample. The kinetics of the thermoluminescence process has been explained phenomenologically. The correspondence between the defect centres and the TL glow peaks has remained vague or ambiguous even in the most widely studied TL materials. Notwithstanding this deficiency, the phenomenon has found many practical applications. The paper deals mainly with the physical processes involved in the TL emission and alludes briefly to its involvement in applied areas.(author). 6 refs., 2 figs

  20. Aquifer thermal energy stores in Germany

    International Nuclear Information System (INIS)

    Kabus, F.; Seibt, P.; Poppei, J.

    2000-01-01

    This paper describes the state of essential demonstration projects of heat and cold storage in aquifers in Germany. Into the energy supply system of the buildings of the German Parliament in Berlin, there are integrated both a deep brine-bearing aquifer for the seasonal storage of waste heat from power and heat cogeneration and a shallow-freshwater bearing aquifer for cold storage. In Neubrandenburg, a geothermal heating plant which uses a 1.200 m deep aquifer is being retrofitted into an aquifer heat storage system which can be charged with the waste heat from a gas and steam cogeneration plant. The first centralised solar heating plant including an aquifer thermal energy store in Germany was constructed in Rostock. Solar collectors with a total area of 1000m 2 serve for the heating of a complex of buildings with 108 flats. A shallow freshwater-bearing aquifer is used for thermal energy storage. (Authors)

  1. Thermoluminescence dosimeters with narrow bandpass filters

    Science.gov (United States)

    Walker, Scottie W.

    2004-07-20

    A dosimetry method exposes more than one thermoluminescence crystals to radiation without using conventional filters, and reads the energy stored in the crystals by converting the energy to light in a conventional manner, and then filters each crystal output in a different portion of the spectrum generated by the crystals.

  2. Storing Renewable Energy in the Hydrogen Cycle.

    Science.gov (United States)

    Züttel, Andreas; Callini, Elsa; Kato, Shunsuke; Atakli, Züleyha Özlem Kocabas

    2015-01-01

    An energy economy based on renewable energy requires massive energy storage, approx. half of the annual energy consumption. Therefore, the production of a synthetic energy carrier, e.g. hydrogen, is necessary. The hydrogen cycle, i.e. production of hydrogen from water by renewable energy, storage and use of hydrogen in fuel cells, combustion engines or turbines is a closed cycle. Electrolysis splits water into hydrogen and oxygen and represents a mature technology in the power range up to 100 kW. However, the major technological challenge is to build electrolyzers in the power range of several MW producing high purity hydrogen with a high efficiency. After the production of hydrogen, large scale and safe hydrogen storage is required. Hydrogen is stored either as a molecule or as an atom in the case of hydrides. The maximum volumetric hydrogen density of a molecular hydrogen storage is limited to the density of liquid hydrogen. In a complex hydride the hydrogen density is limited to 20 mass% and 150 kg/m(3) which corresponds to twice the density of liquid hydrogen. Current research focuses on the investigation of new storage materials based on combinations of complex hydrides with amides and the understanding of the hydrogen sorption mechanism in order to better control the reaction for the hydrogen storage applications.

  3. Using Bacteria to Store Renewable Energy (Text Version) | News | NREL

    Science.gov (United States)

    Using Bacteria to Store Renewable Energy (Text Version) Using Bacteria to Store Renewable Energy is a text version of the video entitled "Using Bacteria to Store Renewable Energy." ; Bacteria from some of the Earth's harshest environments now have a new home at NREL. [A natural spring has

  4. Stored energy analysis in the scaled-down test facilities

    International Nuclear Information System (INIS)

    Deng, Chengcheng; Chang, Huajian; Qin, Benke; Wu, Qiao

    2016-01-01

    Highlights: • Three methods are developed to evaluate stored energy in the scaled-down test facilities. • The mechanism behind stored energy distortion in the test facilities is revealed. • The application of stored energy analysis is demonstrated for the ACME facility of China. - Abstract: In the scaled-down test facilities that simulate the accident transient process of the prototype nuclear power plant, the stored energy release in the metal structures has an important influence on the accuracy and effectiveness of the experimental data. Three methods of stored energy analysis are developed, and the mechanism behind stored energy distortion in the test facilities is revealed. Moreover, the application of stored energy analysis is demonstrated for the ACME test facility newly built in China. The results show that the similarity requirements of three methods analyzing the stored energy release decrease gradually. The physical mechanism of stored energy release process can be characterized by the dimensionless numbers including Stanton number, Fourier number and Biot number. Under the premise of satisfying the overall similarity of natural circulation, the stored energy release process in the scale-down test facilities cannot maintain exact similarity. The results of the application of stored energy analysis illustrate that both the transient release process and integral total stored energy of the reactor pressure vessel wall of CAP1400 power plant can be well reproduced in the ACME test facility.

  5. Measuring thermo-luminescence efficiency of TLD-2000 detectors to different energy photons

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Wei Min; Chen, Bao Wei; Han, Yi; Yang, Zhong Jian [China Institute for Radiation Protection, Taiyuan (China)

    2016-06-15

    As an important detecting device, TLD is a widely used in the radiation monitoring. It is essential for us to study the property of detecting element. The aim of this study is to calculate the thermo-luminescence efficiency of TL elements. A batch of thermo-luminescence elements were irradiated by the filtered X-ray beams of average energies in the range 40-200 kVp, 662 keV {sup 137}Cs gamma rays and then the amounts of lights were measured by the TL reader. The deposition energies in elements were calculated by theory formula and Monte Carlo simulation. The unit absorbed dose in elements by photons with different energies corresponding to the amounts of lights was calculated, which is called the thermo luminescent efficiency (η(E)). Because of the amounts of lights can be calculated by the absorbed dose in elements multiply η(E), the η(E) can be calculated by the experimental data (the amounts of lights) divided by absorbed dose. The deviation of simulation results compared with theoretical calculation results were less than 5%, so the absorbed dose in elements was calculated by simulation results in here. The change range of η(E) value, relative to 662 keV {sup 137}Cs gamma rays, is about 30% in the energy range of 33 keV to 662 keV, is in accordance by the comparison with relevant foreign literatures. The η(E) values can be used for updating the amounts of lights that are got by the direct ratio assumed relations with deposition energy in TL elements, which can largely reduce the error of calculation results of the amounts of lights. These data can be used for the design of individual dosimeter which used TLD-2000 thermo-luminescence elements, also have a certain reference value for manufacturer to improve the energy-response performance of TL elements by formulation adjustment.

  6. Photon and neutron energy response of Thermoluminescent (TL) dosimeters

    International Nuclear Information System (INIS)

    Thilagam, L.; Priya, M.R.; Mohapatra, D.K.

    2018-01-01

    Theoretical Monte Carlo (MC) simulations are carried out to investigate the relative thermoluminesence (TL) response of the most commonly used TLD materials to a wide range of photon energy. The effect of polytetrafluoroethylene (PTFE) on TL response of CaSO 4 :Dy is also studied. Additionally, the neutron response of LiF:Mg,Ti TL materials with different concentrations of 6 Li is estimated in terms of the number of 6 Li(n, t) 4 He capture reactions for a wider neutron energy

  7. Electron-energy deposition in skin and thermoluminescence dosimeters

    International Nuclear Information System (INIS)

    Mei, G.T.Y.

    1986-01-01

    The primary object of this study was to investigate the relations between dosimeter response and skin dose resulting from beta-particle irradiation. This object was achieved by combining evaluation of beta-source energy spectra, calculation of flux energy spectra, and employment of a Monte-Carlo electron-transport computer program for determination of depth-dose distribution in multislab geometries. Intermediate results from three steps of evaluation were compared individually with experimental data or with other theoretical results and showed excellent agreement. The combined method is applicable for the electron agreement. The combined method is applicable for the electron energy range of 1 keV to 5 MeV for both monoenergetic electrons and energy-distributed electrons. Determination of dosimeter response - skin dose relationships for homogeneous atmospheric beta-particle sources and for two specific configurations of LiF TLD's have been carried out in this study. Information based on these calculations is of value in designing beta-particle dosimeters as well as in assessing potential occupational and public health risks associated with the nuclear power industry

  8. Stored energy analysis in scale-down test facility

    International Nuclear Information System (INIS)

    Deng Chengcheng; Qin Benke; Fang Fangfang; Chang Huajian; Ye Zishen

    2013-01-01

    In the integral test facilities that simulate the accident transient process of the prototype nuclear power plant, the stored energy in the metal components has a direct influence on the simulation range and the test results of the facilities. Based on the heat transfer theory, three methods analyzing the stored energy were developed, and a thorough study on the stored energy problem in the scale-down test facilities was further carried out. The lumped parameter method and power integration method were applied to analyze the transient process of energy releasing and to evaluate the average total energy stored in the reactor pressure vessel of the ACME (advanced core-cooling mechanism experiment) facility, which is now being built in China. The results show that the similarity requirements for such three methods to analyze the stored energy in the test facilities are reduced gradually. Under the condition of satisfying the integral similarity of natural circulation, the stored energy releasing process in the scale-down test facilities can't maintain exact similarity. The stored energy in the reactor pressure vessel wall of ACME, which is released quickly during the early stage of rapid depressurization of system, will not make a major impact on the long-term behavior of system. And the scaling distortion of integral average total energy of the stored heat is acceptable. (authors)

  9. Storing the Electric Energy Produced by an AC Generator

    Science.gov (United States)

    Carvalho, P. Simeao; Lima, Ana Paula; Carvalho, Pedro Simeao

    2010-01-01

    Producing energy from renewable energy sources is nowadays a priority in our society. In many cases this energy comes as electric energy, and when we think about electric energy generators, one major issue is how we can store that energy. In this paper we discuss how this can be done and give some ideas for applications that can serve as a…

  10. Thermoluminescence of films of metal oxides and its application to the low energy ionizing radiation dosimetry

    International Nuclear Information System (INIS)

    Azorin N, J.; Rivera M, T.; Furetta, C.; Falcony G, C.; Martinez S, E.; Garcia H, M.

    2002-01-01

    The obtained results from 1997 to date in the project S tudy of the thermoluminescence of metal oxides and their application to the ionizing radiation as regards to the development of ZrO 2 and of Al 2 O 3 doped and without doped films with rare earths are presented. The obtained results irradiating ZrO 2 and of Al 2 O 3 films with ultraviolet light and visible light have been satisfactory; whereas these materials have resulted promising to measure beta particles, X-rays and low energy gamma rays. (Author)

  11. A method for reducing energy dependence of thermoluminescence dosimeter response by means of filters

    International Nuclear Information System (INIS)

    Bapat, V.N.

    1980-01-01

    This work describes the application of the method of partial surface shielding for reducing the energy dependence of the X-ray and γ-ray response of a dosimeter containing a CaSO 4 :Dy thermoluminescent phosphor mixed with KCl. in pellet form. Results are given of approximate computation of filter combinations that accomplish this aim, and of experimental verifications. Incorporation of the described filter combination makes it possible to use this relatively sensitive dosimeter for environmental radiation monitoring. A similar approach could be applied to any type of dosimeter in the form of a thin pellet or wafer. (author)

  12. Application of thermoluminescence dosimeter on the measurement of hard X-ray pulse energy spectrum

    International Nuclear Information System (INIS)

    Song Zhaohui; Wang Baohui; Wang Kuilu; Hei Dongwei; Sun Fengrong; Li Gang

    2003-01-01

    This paper introduces the application of thermoluminescence dosimeter (TLD) which composed by TLD-3500 reader and GR-100 M chips on the measurement of hard X-ray pulse energy spectrum. The idea using Filter Fluorescence Method (FFM) and TLD to measure hard X-ray pulse energy spectrum (from 10 keV to 100 keV) is discussed in details. Considering all the factors of the measuring surrounding, the measurement system of hard X-ray pulse has been devised. The calibration technique of absolute energy response of TLD is established. This method has been applied successfully on the radiation parameters measurement of the huge pulse radiation device-high-power pulser I. Hard X-ray pulse energy spectrum data of the pulser are acquired

  13. The application of thermoluminescence dosimeter on the measurement of hard X-ray pulse energy spectrum

    International Nuclear Information System (INIS)

    Song Zhaohui; Wang Baohui; Wang Kuilu; Hei Dongwei; Sun Fengrong; Li Gang

    2001-01-01

    This paper introduce the application of thermoluminescence dosimeter (TLD) which composed by TLD-3500 Reader and TLD-100M chips on the measurement of hard X-ray pulse energy spectrum. The idea, using Filter Fluorescence Method (FFM) and TLD to measure hard X-ray pulse energy spectrum (from 10 keV to 100 keV), is discussed in details. Considering all the factors of the measuring surroundings, the measurement system of hard X-ray pulse has been devised. The calibration technique of absolute energy response of TLD is established. This method has been applied successfully on the radiation parameters measurement of the huge pulse radiation device -high-power pulser I. Hard X-ray pulse energy spectrum data of the pulser are acquired

  14. High-current pulses from inductive energy stores

    International Nuclear Information System (INIS)

    Wipf, S.L.

    1981-01-01

    Superconducting inductive energy stores can be used for high power pulse supplies if a suitable current multiplication scheme is used. The concept of an inductive Marx generator is superior to a transformer. A third scheme, a variable flux linkage device, is suggested; in multiplying current it also compresses energy. Its function is in many ways analogous to that of a horsewhip. Superconductor limits indicate that peak power levels of TW can be reached for stored energies above 1 MJ

  15. Stores

    CERN Multimedia

    2004-01-01

    Following the introduction of Condensators, resistors and potentiometers from the Farnell electronic-catalogue into CERN Stores' catalogue, following products are now available: PRODUCT FAMILY GROUP SCEM Oscillators and quartz crystals 07.94.10 / 07.94.12 Diodes 08.51.14 / 08.51.54 Thyristors 08.51.60 / 08.51.66 Opto-electronics 08.52 Transistors 08.53 Integrated circuits 08.54 / 08.55 These articles can be procured in the same way as any other stores item, by completing a Material Request. N.B. Individual Farnell order codes can be used as keywords to facilitate searches in the CERN Stores Catalogue.

  16. Design feasibility of an intermittent domestic energy store

    Energy Technology Data Exchange (ETDEWEB)

    Tahat, M.A. [Jordan Univ. of Sceince and Technology, Irbid (Jordan). Dept. of Mechanical Engineering; Babus`Haq, R.F.; O`Callaghan, P.W.; Probert, S.D. [Cranfield Univ., Bedford (United Kingdom). Dept. of Applied Energy

    1995-09-01

    In recent years, energy storage has been recognised as a potentially significant means by which primary energy consumption can be reduced in domestic, commercial and industrial processes. An intermittent domestic thermochemical heat pump, with a 5 kW{sub e} electric power output when employed as an energy store, is proposed. Different design options have been considered and their economic feasibilities evaluated. (author)

  17. Thermoluminescence of metal oxides and its applications to the dosimetry of low energy ionizing radiation

    International Nuclear Information System (INIS)

    Azorin N, J.; Rivera M, T.; Falcony G, C.; Martinez S, E.; Garcia H, M.

    1999-01-01

    There are presented the results obtained since 1997 at present in the project Study of the thermoluminescence of metal oxides and its applications to the dosimetry of ionizing radiation. Its have been developed ZrO 2 films without doping and doped with Eu, Tb, and Mn as well as Al 2 O 3 films without doping and doped with Na. The results obtained to the irradiated films of ZrO 2 with ultraviolet and visible lights have been satisfactory. The Al 2 O 3 in film form showed to be a promising material for the measuring ultraviolet light and the pellets of ZrO 2 + Ptfe for X-rays and low energy gamma rays. (Author)

  18. A model for stored energy in amorphous silica

    International Nuclear Information System (INIS)

    Tinivella, G.

    1980-12-01

    The observed saturation value of stored energy in irradiated amorphous silica is too big to be explained by the energy of recombined non-grouped defects. The hypothesis that it can be due to a structural change has been tested, and a simple model based on the fluctuation of the atomic distances shows a reasonable agreement with the experimental data. (author)

  19. Pressure Systems Stored-Energy Threshold Risk Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Paulsen, Samuel S.

    2009-08-25

    Federal Regulation 10 CFR 851, which became effective February 2007, brought to light potential weaknesses regarding the Pressure Safety Program at the Pacific Northwest National Laboratory (PNNL). The definition of a pressure system in 10 CFR 851 does not contain a limit based upon pressure or any other criteria. Therefore, the need for a method to determine an appropriate risk-based hazard level for pressure safety was identified. The Laboratory has historically used a stored energy of 1000 lbf-ft to define a pressure hazard; however, an analytical basis for this value had not been documented. This document establishes the technical basis by evaluating the use of stored energy as an appropriate criterion to establish a pressure hazard, exploring a suitable risk threshold for pressure hazards, and reviewing the methods used to determine stored energy. The literature review and technical analysis concludes the use of stored energy as a method for determining a potential risk, the 1000 lbf-ft threshold, and the methods used by PNNL to calculate stored energy are all appropriate. Recommendations for further program improvements are also discussed

  20. The network-based energy management system for convenience stores

    Energy Technology Data Exchange (ETDEWEB)

    Wang, An-Ping; Hsu, Pau-Lo [Department of Electrical and Control Engineering, National Chiao-Tung University, 1001 Ta-Hsiue Road, Hsinchu City 310 (China)

    2008-07-01

    Convenience stores generally consume energy higher than other retailing merchants. As the problem of energy shortage becomes more serious during summer, almost all convenience stores sign a contract with power plants, which provides for fines if demand limiting occurs in Taiwan and many other countries. Therefore, a reliable and effective method to reduce their utility consumption is required for modern business and industry. This research integrates the remote sensors, the control network, and the embedded system technologies to construct a distributed energy management control system for dedicated convenience stores. Energy consumption can thus be reasonably managed with demand limits by measuring and analyzing the power consumption sources in four major subsystems of convenience stores, namely, (1) air-conditioning, (2) lighting, (3) heating, and (4) refrigeration. By applying the proposed demand prediction and control method, the demand limiting condition can be properly predicted, and the possible peak load can thus be eliminated via the network control mechanism. Moreover, by integrating the LonWork fieldbus and the WinCE operating system (OS), the proposed system has been successfully applied to a convenience store. The experimental results indicate that the proposed distributed energy management system suitably predicts the peak loading condition and successfully prevents its occurrence by switching the air-conditioning system without affecting the indoor temperature regulation. (author)

  1. Stored energy in fusion magnet materials irradiated at low temperatures

    International Nuclear Information System (INIS)

    Chaplin, R.L.; Kerchner, H.R.; Klabunde, C.E.; Coltman, R.R.

    1989-08-01

    During the power cycle of a fusion reactor, the radiation reaching the superconducting magnet system will produce an accumulation of immobile defects in the magnet materials. During a subsequent warm-up cycle of the magnet system, the defects will become mobile and interact to produce new defect configurations as well as some mutual defect annihilations which generate heat-the release of stored energy. This report presents a brief qualitative discussion of the mechanisms for the production and release of stored energy in irradiated materials, a theoretical analysis of the thermal response of irradiated materials, theoretical analysis of the thermal response of irradiated materials during warm-up, and a discussion of the possible impact of stored energy release on fusion magnet operation 20 refs

  2. Spatial energy distribution around energetic ions in condensed phases. Study by thermoluminescence

    International Nuclear Information System (INIS)

    Montret-Brugerolle, M.

    1980-01-01

    One describes a model that allows the calculation of the spatial energy distribution around a heavy ion trajectory within the physical step of the phenomena involved (10 -13 s). Experimental data are collected in order to chek the model in the condensed phase. The experimental procedure is thermoluminescence (TL). LiF : Mg, Ti, CaF 2 : Dy and CaF 2 : Mn crystals are irradiated with 60 Co-γ rays and with heavy ions: He, Ne, Cu, Kr of various incident energies. An extensive study of the TL light induced by heavy ions bombardment is carried out as a function of the energy and density of the impinging ions. It is shown that the different response observed with respect to γ-irradiation is due neither to TL traps destruction nor to the recombination of a larger amount of charge-carriers. Experimental data and those obtained from the distribution of energy density are compared, and the agreement is satisfactory. Hence, it is thought that the model may be extended to condensed media [fr

  3. Measurement of the energy stored in alkalihalogenids by radiation defects

    International Nuclear Information System (INIS)

    Schrey, P.

    1976-01-01

    The energy stored in alkali-halogen crystals after X-ray irradiation is studied at 11 K. Using a heat flux calorimeter designed especially for this experiment, single crystals are irradiated and the energy release is recorded as the temperature is increased proportional to time from 10 K to 50 K. The energy release spectra are compared with relevant optical measurements and thus a relation between energy release and tempering of point defects is established. The energy release peaks can be assigned definitly to tempering stages of the Frenkel pairs. For explanation a simple model is proposed. (orig./HPOE) [de

  4. Electron, photons, and molecules: Storing energy from light

    Energy Technology Data Exchange (ETDEWEB)

    Miller, J.R. [Argonne National Laboratory, IL (United States)

    1996-09-01

    Molecular charge separation has important potential for photochemical energy storage. Its efficiency can be enhanced by principals which maximize the rates of the electron transfer steps which separate charge and minimize those which recombine high-energy charge pairs to lose stored energy. Dramatic scientific progress in understanding these principals has occurred since the founding of DOE and its predecessor agency ERDA. While additional knowledge in needed in broad areas of molecular electron transfer, some key areas of knowledge hold particular promise for the possibility of moving this area from science toward technology capable of contributing to the nation`s energy economy.

  5. Safety consequences of the release of radiation induced stored energy

    International Nuclear Information System (INIS)

    Prij, J.

    1994-08-01

    Due to the disposal of HLW in a salt formation gamma energy will be deposited in the rock salt. Most of this energy will be converted into heat, whilst a small part will create defects in the salt crystals. Energy is stored in the damaged crystals. Due to uncertainties in the models and differences in the disposal concepts the estimated values for the stored energy range from 10 to 1000 J/g in the most heavily damaged crystals close to the waste containers. The amount of radiation damage decays exponentially with increasing distance from the containers and at distances larger than 0.2 m the stored energy can be neglected. Given the uncertainties in the model predictions and in the possible release mechanism an instantaneous release of stored energy cannot be excluded completely. Therefore the thermo-mechanical consequences of a postulated instantaneous release of an extremely high amount of radiation induced stored energy have been estimated. These estimations are based on the quasi-static solutions for line and point sources. To account for the dynamic effects and the occurrence of fractures an amplification factor has been derived from mining experience with explosives. A validation of this amplification factor has been given using post experimental observations of two nuclear explosions in a salt formation. For some typical disposal concepts in rock salt the extent of the fractured zone has been estimated. It appeared that the radial extent of the fractured zone is limited to 5 m. Given the much larger distance between the individual boreholes and the distance between the boreholes and the boundary of the salt formation (more than 100 m), the probability of a release of radiation induced stored energy creating a pathway for the nuclides from the containers to the groundwater, is extremely low. The radiological consequences of a groundwater intrusion scenario induced by this very unprobable pathway are bounded by the 'standard' groundwater intrusion

  6. SIMULATIONS OF THE AGS MMPS STORING ENERGY IN CAPACITOR BANKS

    Energy Technology Data Exchange (ETDEWEB)

    MARNERIS,I.; BADEA, V.S.; BONATI, R.; ROSER, T.; SANDBERG, J.

    2007-06-25

    The Brookhaven AGS Main Magnet Power Supply (MMPS) is a thyristor control supply rated at 5500 Amps, +/-9000 Volts. The peak magnet power is 50 MWatts. The power supply is fed from a motor/generator manufactured by Siemens. The generator is 3 phase 7500 Volts rated at 50 MVA. The peak power requirements come from the stored energy in the rotor of the motor/generator. The motor generator is about 45 years old, made by Siemens and it is not clear if companies will be manufacturing similar machines in the future. We are therefore investigating different ways of storing energy for future AGS MMPS operations. This paper will present simulations of a power supply where energy is stored in capacitor banks. Two dc to dc converters will be presented along with the control system of the power section. The switching elements will be IGCT's made by ABB. The simulation program used is called PSIM version 6.1. The average power from the local power authority into the power supply will be kept constant during the pulsing of the magnets at +/-50 MW. The reactive power will also be kept constant below 1.5 MVAR. Waveforms will be presented.

  7. SIMULATIONS OF THE AGS MMPS STORING ENERGY IN CAPACITOR BANKS

    International Nuclear Information System (INIS)

    MARNERIS, I.; BADEA, V.S.; BONATI, R.; ROSER, T.; SANDBERG, J.

    2007-01-01

    The Brookhaven AGS Main Magnet Power Supply (MMPS) is a thyristor control supply rated at 5500 Amps, +/-9000 Volts. The peak magnet power is 50 MWatts. The power supply is fed from a motor/generator manufactured by Siemens. The generator is 3 phase 7500 Volts rated at 50 MVA. The peak power requirements come from the stored energy in the rotor of the motor/generator. The motor generator is about 45 years old, made by Siemens and it is not clear if companies will be manufacturing similar machines in the future. We are therefore investigating different ways of storing energy for future AGS MMPS operations. This paper will present simulations of a power supply where energy is stored in capacitor banks. Two dc to dc converters will be presented along with the control system of the power section. The switching elements will be IGCT's made by ABB. The simulation program used is called PSIM version 6.1. The average power from the local power authority into the power supply will be kept constant during the pulsing of the magnets at +/-50 MW. The reactive power will also be kept constant below 1.5 MVAR. Waveforms will be presented

  8. Stored energy calculation: the state of the art

    International Nuclear Information System (INIS)

    Cunningham, M.E.; Lanning, D.D.; Olsen, A.R.; Williford, R.E.; Hann, C.R.

    1978-05-01

    The report is the result of an investigation to determine the current state of the art of fuel temperature, gap conductance, and stored energy calculations. Major emphasis was placed on the propagation of input and model uncertainties. To support this study a comparison was made to the observed variability of experimental data for fuel centerline temperature and gap conductance values. The uncertainty analysis was performed by identifying major thermal models and collecting them into an abstract of a thermal performance code. Uncertainties in the calculations were determined using the method of propagation of uncertainties with a first order Taylor series approximation to the nonlinear functions. Output uncertainty results are presented for the beginning of fuel life, the end of life, and throughout a typical power history. Also presented is an influence and importance analysis for the input parameters. It is concluded that the relative uncertainty in stored energy is approximately +-20 percent at beginning of fuel life, and increases to +-25 to 40 percent contact. The foregoing are 3 sigma (99.9 percent) confidence intervals. The most important contributors to stored energy uncertainty are linear heat rating and fuel thermal conductivity

  9. Protection of large-stored-energy superconducting coils

    International Nuclear Information System (INIS)

    Kircher, F.

    1975-11-01

    When the stored energy of superconducting magnets increases, the problem of the protection of the coil when a quench occurs becomes more and more important, especially if the structure of the coil is such that the energy can be dissipated only in a small part of the coil. The aim of this paper is first to describe a program which enables to predict the increase of temperature inside the coil for several kinds of protection and to give results for KEK pulsed dipoles (under construction and planned for TRISTAN). (auth.)

  10. THERMOLUMINESCENT DOSIMETRY

    Energy Technology Data Exchange (ETDEWEB)

    Malsky, Stanley J.; Amato, Charles G.; Roswit, Bernard

    1963-06-15

    The performance of CaF/sub 2/: Mn and LiF as thermoluminescent in vivo dosimeters is studied. The facility with which this type of dosimeter can be inserted into the body is discussed. The dosimeter is inserted into the body by trocar or catheter techniques and exposed to radiation; it is then removed and heated, and the thermoluminescence is measured and used as an indication of the absorbed dose. (T.F.H.)

  11. New results with stored exotic nuclei at relativistic energies

    Energy Technology Data Exchange (ETDEWEB)

    Bosch, F. (Fritz); Boutin, D. (Daniel); Fastermann, T. (Thomas); Falch, M. (Markus); Franzke, B. (Bernhard); Hausmann, M. (Marc); Hellstrom, M. (Margarete); Kaza, E. (Evangelia); Kerscher, T. (Thomas); Klepper, O. (Otto); Kluge, H.-Jürgen; Kozhuharov, C. (Christophor); Kratz, K. L.; Litinov, S. A. (Sergei A); Lobner, G. K. E. (Gunther K. E.); Maier, L. (Ludwig); Matos, M. (Milan); Munzenberg, G. (Gottfried); Nolden, F. (Fritz); Novikov, Y. N. (Yuri N.); Ohtsubo, T. (Takashi); Ostrowski, A. (Alexander); Patyk, Z. (Zygmund); Pfeiffer, B.; Portillo, M. (Mauricio); Radon, T. P. (Torsten P.); Scheidenberger, C. (Christoph); Shishkin, V. (Vladimir); Stadlman, J. (Jens); Steck, M. (Markus); Vieira, D. J. (David J.); Weick, H. (Helmut); Winkler, M. (Martin); Wollnik, Hermann; Yamaguchi, T. (Takayuki)

    2004-01-01

    Recently, much progress has been made with stored exotic nuclei at relativistic velocities v/c = 0.7. Fragments of {sup 208}Pb and {sup 209}Bi projectiles and fission fragments from {sup 238}U ions have been produced, separated in flight with the fragment separator FRS, and injected into the storage-cooler ring ESR for precision measurements. Precise masses of neutron-deficient isotopes in the lead region have been measured with time-resolved Schottky Mass Spectrometry (SMS). A new isospin dependence of the pairing energy was observed due to the improved mass accuracy of typical 1.5 x 10{sup -7} (30 keV). New masses of short-lived neutron-rich fission fragments have been obtained with Isochronous Mass Spectrometry (IMS). An innovative field of spectroscopy has been opened up with lifetime measurements of stored bare and few-electron fragments after applying both stochastic and electron cooling.

  12. Thermoluminescent characteristics of CaSO4:Dy+PTFE irradiated with high energy electron beams

    International Nuclear Information System (INIS)

    Alvarez, R.; Rivera, T.; Calderon, J. A.; Jimenez, Y.; Rodriguez, J.; Oviedo, O.; Azorin, J.

    2011-10-01

    In the present work thermoluminescent response of dysprosium doped calcium sulfate embedded in polytetrafluorethylene (CaSO 4 :Dy+PTFE) under high electron beam irradiations from linear accelerator for clinical applications was investigated. The irradiations were carried out using high electron beams (6 to 18 MeV) from a linear accelerator Varian, C linac 2300C/D, for clinical practice purpose. The electron irradiations were obtained by using the water solid in order to guarantee electronic equilibrium conditions. Field shaping for electron beams was obtained with electron cones. Glow curve and other thermoluminescent characteristics of CaSO 4 :Dy+PTFE were conducted under high electron beams irradiations. The thermoluminescent response of the pellets showed and intensity peak centered at around 235 C. Thermoluminescent response of CaSO 4 :Dy+PTFE as a function of high electron absorbed dose showed a linearity in a wide range. To obtain reproducibility characteristic, a set of pellets were exposed repeatedly for the same electron absorbed dose. The results obtained in this study can suggest the applicability of CaSO 4 :Dy+PTFE pellets for high electron beam dosimetry, provided fading is correctly accounted for. (Author)

  13. Energy saving by optimized controls for supermarket stores; Energie sparen mit optimierter Regeltechnik im Supermarkt

    Energy Technology Data Exchange (ETDEWEB)

    Wendelborn, Horst [Danfoss GmbH, Offenbach (Germany)

    2011-06-15

    Danfoss has been delivering for 20 years the optimizing ADAP-KOOL(R) control system. It enables the store to save 30% of the yearly energy bill, compared to a store with electronic standard controls. Over years the stores took the cheap standard solution, but now several German supermarket chains decide to take the best for the investment and lifecycle cost. This article describes the main control circuits and shows the measurements of the energy consumption of two stores with standard and optimized controls. This control system is available for chemical and for the natural refrigerant R744. (orig.)

  14. Globally optimal, minimum stored energy, double-doughnut superconducting magnets.

    Science.gov (United States)

    Tieng, Quang M; Vegh, Viktor; Brereton, Ian M

    2010-01-01

    The use of the minimum stored energy current density map-based methodology of designing closed-bore symmetric superconducting magnets was described recently. The technique is further developed to cater for the design of interventional-type MRI systems, and in particular open symmetric magnets of the double-doughnut configuration. This extends the work to multiple magnet domain configurations. The use of double-doughnut magnets in MRI scanners has previously been hindered by the ability to deliver strong magnetic fields over a sufficiently large volume appropriate for imaging, essentially limiting spatial resolution, signal-to-noise ratio, and field of view. The requirement of dedicated interventional space restricts the manner in which the coils can be arranged and placed. The minimum stored energy optimal coil arrangement ensures that the field strength is maximized over a specific region of imaging. The design method yields open, dual-domain magnets capable of delivering greater field strengths than those used prior to this work, and at the same time it provides an increase in the field-of-view volume. Simulation results are provided for 1-T double-doughnut magnets with at least a 50-cm 1-ppm (parts per million) field of view and 0.7-m gap between the two doughnuts. Copyright (c) 2009 Wiley-Liss, Inc.

  15. Unraveling thermoluminescence

    CERN Document Server

    Sunta, C M

    2014-01-01

    The book is essentially about the theoretical aspects of thermoluminescence (TL). It is structured and written in a manner which will specially be of interest to the fresh undergraduate students and young researchers planning to take up work in the field of thermoluminescence. It is arranged into seven chapters, starting with the historical growth of the subject of TL and an overview of the luminescence phenomena. A Physical model involving thermally disconnected deep traps is specially described. Using this model expressions are derived for the TL intensity growth curve, the supralinearity fa

  16. Technical Support Document: Development of the Advanced Energy Design Guide for Grocery Stores--50% Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hale, E. T.; Macumber, D. L.; Long, N. L.; Griffith, B. T.; Benne, K. S.; Pless, S. D.; Torcellini, P. A.

    2008-09-01

    This report provides recommendations that architects, designers, contractors, developers, owners, and lessees of grocery store buildings can use to achieve whole-building energy savings of at least 50% over ASHRAE Standard 90.1-2004.

  17. Treated Carbon Nanofibers for Storing Energy in Aqueous KOH

    Science.gov (United States)

    Firsich, David W.

    2004-01-01

    A surface treatment has been found to enhance the performances of carbon nanofibers as electrode materials for electrochemical capacitors in which aqueous solutions of potassium hydroxide are used as the electrolytes. In the treatment, sulfonic acid groups are attached to edge plane sites on carbon atoms. The treatment is applicable to a variety of carbon nanofibers, including fibrils and both single- and multiple-wall nanotubes. The reason for choosing nanofibers over powders and other forms of carbon is that nanofibers offer greater power features. In previous research, it was found that the surface treatment of carbon nanofibers increased energy-storage densities in the presence of acid electrolytes. Now, it has been found that the same treatment increases energy-storage densities of carbon nanofibers in the presence of alkaline electrolytes when the carbon is paired with a NiOOH electrode. This beneficial effect varies depending on the variety of carbon substrate to which it is applied. It has been conjectured that the sulfonic acid groups, which exist in a deprotonated state in aqueous KOH solutions, undergo reversible electro-chemical reactions that are responsible for the observed increases in energystorage capacities. The increases can be considerable: For example, in one case, nanofibers exhibited a specific capacitance of 34 Farads per gram before treatment and 172 Farads per gram (an increase of about 400 percent) after treatment. The most promising application of this development appears to lie in hybrid capacitors, which are devices designed primarily for storing energy. These devices are designed to be capable of (1) discharge at rates greater than those of batteries and (2) storing energy at densities approaching those of batteries. A hybrid capacitor includes one electrode like that of a battery and one electrode like that of an electrochemical capacitor. For example, a hybrid capacitor could contain a potassium hydroxide solution as the electrolyte

  18. Superconducting magnetic energy storage for electric utility load leveling: A study of cost vs. stored energy

    International Nuclear Information System (INIS)

    Luongo, C.A.; Loyd, R.J.

    1987-01-01

    Superconducting Magnetic Energy Storage (SMES) is a promising technology for electric utility load leveling. This paper presents the results of a study to establish the capital cost of SMES as a function of stored energy. Energy-related coil cost and total installed plant cost are given for construction in nominal soil and in competent rock. Economic comparisons are made between SMES and other storage technologies and peaking gas turbines. SMES is projected to be competitive at stored energies as low as 1000 MWh

  19. Thermoluminescence of LiNaSo4: TI after exposure to radiation doses from electrons of different energies

    International Nuclear Information System (INIS)

    El-Kolaly, M.A.

    2002-01-01

    Lithium sodium sulphate doped by rare impurities (LiNaSO 4 : TI) has been locally prepared. Its Thermoluminescence properties (TL) have been performed from room temperature up to 300 degree C. The used heating rate was 5 degree C/sec. The samples were irradiated by electrons of different energies (5, 7, 9 and 13 MeV.). These samples were exposed to different duration to attain different radiation doses. It has been observed that the glow curves are consisted of four glow peaks at 75, 125, 225 and 250 degree C respectively. The first peak showed a linear dependence with electron radiation doses and can be used in radiation measurement. The irradiated impurities LiNaSO 4 : TI with energies higher than 5 MeV showed no appreciable change in the TL peak height. The obtained results will explore the probability of using such system (double sulphates doped by rare earth impurities) in the field of radiation measurements

  20. Modeling of gamma ray energy-absorption buildup factors for thermoluminescent dosimetric materials using multilayer perceptron neural network

    DEFF Research Database (Denmark)

    Kucuk, Nil; Manohara, S.R.; Hanagodimath, S.M.

    2013-01-01

    In this work, multilayered perceptron neural networks (MLPNNs) were presented for the computation of the gamma-ray energy absorption buildup factors (BA) of seven thermoluminescent dosimetric (TLD) materials [LiF, BeO, Na2B4O7, CaSO4, Li2B4O7, KMgF3, Ca3(PO4)2] in the energy region 0.015–15Me......V, and for penetration depths up to 10 mfp (mean-free-path). The MLPNNs have been trained by a Levenberg–Marquardt learning algorithm. The developed model is in 99% agreement with the ANSI/ANS-6.4.3 standard data set. Furthermore, the model is fast and does not require tremendous computational efforts. The estimated BA...

  1. Limitation of peak fitting and peak shape methods for determination of activation energy of thermoluminescence glow peaks

    CERN Document Server

    Sunta, C M; Piters, T M; Watanabe, S

    1999-01-01

    This paper shows the limitation of general order peak fitting and peak shape methods for determining the activation energy of the thermoluminescence glow peaks in the cases in which retrapping probability is much higher than the recombination probability and the traps are filled up to near saturation level. Right values can be obtained when the trap occupancy is reduced by using small doses or by post-irradiation partial bleaching. This limitation in the application of these methods has not been indicated earlier. In view of the unknown nature of kinetics in the experimental samples, it is recommended that these methods of activation energy determination should be applied only at doses well below the saturation dose.

  2. Stored energy and annealing behavior of heavily deformed aluminium

    DEFF Research Database (Denmark)

    Kamikawa, Naoya; Huang, Xiaoxu; Kondo, Yuka

    2012-01-01

    It has been demonstrated in previous work that a two-step annealing treatment, including a low-temperature, long-time annealing and a subsequent high-temperature annealing, is a promising route to control the microstructure of a heavily deformed metal. In the present study, structural parameters...... are quantified such as boundary spacing, misorientation angle and dislocation density for 99.99% aluminium deformed by accumulative roll-bonding to a strain of 4.8. Two different annealing processes have been applied; (i) one-step annealing for 0.5 h at 100-400°C and (ii) two-step annealing for 6 h at 175°C...... followed by 0.5 h annealing at 200-600°C, where the former treatment leads to discontinuous recrystallization and the latter to uniform structural coarsening. This behavior has been analyzed in terms of the relative change during annealing of energy stored as elastic energy in the dislocation structure...

  3. Electron beam energy monitoring using thermoluminescent dosimeters and electron back scattering

    International Nuclear Information System (INIS)

    Nelson, Vinod; Gray, Alison

    2013-01-01

    Periodic checks of megavoltage electron beam quality are a fundamental requirement in ensuring accurate radiotherapy treatment delivery. In the present work, thermoluminescent dosimeters (TLDs) positioned on either side of a lead sheet at the surface of a water equivalent phantom were used to monitor electron beam quality using the electron backscattering method. TLD100 and TLD100H were evaluated as upstream detectors and TLD200, TLD400 and TLD500 were evaluated as downstream detectors. The evaluation assessed the test sensitivity and correlation, long and short term reproducibility, dose dependence and glow curve features. A prototype of an in-air jig suitable for use in postal TLD dose audits was also developed and an initial evaluation performed. The results indicate that the TLD100-TLD200 combination provides a sensitive and reproducible method to monitor electron beam quality. The light weight and easily fabricated in-air jig was found to produce acceptable results and has the potential to be used by radiation monitoring agencies to carry out TLD postal quality assurance audits, similar to audits presently being conducted for photon beams. -- Highlights: ► Monitoring electron beam quality via electron backscattering was investigated. ► Different thermoluminescent materials were evaluated as detectors. ► A TLD100-TLD200 combination produced the most sensitive and reproducible results. ► An in-air jig was evaluated to allow measurements via postal dose audits

  4. Mexican gems as thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Azorin N, J.

    1979-01-01

    The possibility of using naturally ocurring mexican gems as thermoluminescent dosimeters (TLD) was investigated. Twelve types of gems were irradiated with X and gamma rays in order to determinate their dosimetric properties. Three of these gems showed favorable thermoluminescent characteristics compared with commercial thermoluminescent dosimeters. The plots of their thermoluminescent response as a function of gamma dose are straight lines on full log paper in the dose range 10 -2 to 10 2 Gy. The energy dependence is very strong to low energies of the radiation. Their fading was found to be about 5%/yr. and they may be annealed as reused without loss in sensitivity. Therefore, these gems can be used as X and gamma radiation dosimeters. (author)

  5. Thermoluminescence and applications

    International Nuclear Information System (INIS)

    Rodrigues, G.V.

    1986-01-01

    The theory of thermoluminescent emission, the characteristics of main thermoluminescent phosphorus, and some applications are presented. The main thermoluminescent dosemeters used in dosimetry are related. (M.C.K.)

  6. Thermoluminescence and their applications

    International Nuclear Information System (INIS)

    Rodrigues, G.V.

    1986-01-01

    The theory involved in the phenomenon of thermoluminescence emission, the characteristics of the main thermoluminescent phosphorus and some of their applications are presented. Some of the main thermoluminescent dosemeters used in dosimetry are described. (M.C.K.) [pt

  7. Thermoluminescent phosphor

    Science.gov (United States)

    Lasky, Jerome B.; Moran, Paul R.

    1978-01-01

    A thermoluminescent phosphor comprising LiF doped with boron and magnesium is produced by diffusion of boron into a conventional LiF phosphor doped with magnesium. Where the boron dopant is made to penetrate only the outer layer of the phosphor, it can be used to detect shallowly penetrating radiation such as tritium beta rays in the presence of a background of more penetrating radiation.

  8. Polynomial expressions of electron depth dose as a function of energy in various materials: application to thermoluminescence (TL) dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Deogracias, E.C.; Wood, J.L.; Wagner, E.C.; Kearfott, K.J

    1999-02-11

    The CEPXS/ONEDANT code package was used to produce a library of depth-dose profiles for monoenergetic electrons in various materials for energies ranging from 500 keV to 5 MeV in 10 keV increments. The various materials for which depth-dose functions were derived include: lithium fluoride (LiF), aluminium oxide (Al{sub 2}O{sub 3}), beryllium oxide (BeO), calcium sulfate (CaSO{sub 4}), calcium fluoride (CaF{sub 2}), lithium boron oxide (LiBO), soft tissue, lens of the eye, adiopose, muscle, skin, glass and water. All materials data sets were fit to five polynomials, each covering a different range of electron energies, using a least squares method. The resultant three dimensional, fifth-order polynomials give the dose as a function of depth and energy for the monoenergetic electrons in each material. The polynomials can be used to describe an energy spectrum by summing the doses at a given depth for each energy, weighted by the spectral intensity for that energy. An application of the polynomial is demonstrated by explaining the energy dependence of thermoluminescent detectors (TLDs) and illustrating the relationship between TLD signal and actual shallow dose due to beta particles.

  9. BaSO4:Eu as an energy independent thermoluminescent radiation dosimeter for gamma rays and C6+ ion beam

    Science.gov (United States)

    Sharma, Kanika; Bahl, Shaila; Singh, Birendra; Kumar, Pratik; Lochab, S. P.; Pandey, Anant

    2018-04-01

    BaSO4:Eu nanophosphor is delicately optimized by varying the concentration of the impurity element and compared to the commercially available thermoluminescent dosimeter (TLD) LiF:Mg,Ti (TLD-100) and by extension also to CaSO4:Dy (TLD-900) so as to achieve its maximum thermoluminescence (TL) sensitivity. Further, the energy dependence property of this barite nanophosphor is also explored at length by exposing the phosphor with 1.25 MeV of Co-60, 0.662 MeV of Cs-137, 85 MeV and 65 MeV of Carbon ion beams. Various batches of the phosphor at hand (with impurity concentrations being 0.05, 0.10, 0.20, 0.50 and 1.00 mol%) are prepared by the chemical co-precipitation method out of which BaSO4:Eu with 0.20 mol% Eu exhibits the maximum TL sensitivity. Further, the optimized nanophosphor exhibits a whopping 28.52 times higher TL sensitivity than the commercially available TLD-100 and 1.426 times higher sensitivity than TLD-900, a noteworthy linear response curve for an exceptionally wide range of doses i.e. 10 Gy to 2 kGy and a simple glow curve structure. Furthermore, when the newly optimized nanophosphor is exposed with two different energies of gamma radiations, namely 1.25 MeV of Co-60 (dose range- 10-300 Gy) and 0.662 MeV of Cs-137 (dose range- 1-300 Gy), it is observed that the shape and structure of the glow curves remain remarkably similar for different energies of radiation while the TL response curve shows little to no variation. When exposed to different energies of carbon ion beam BaSO4:Eu displays energy independence at lower doses i.e. from 6.059 to 14.497 kGy. Finally, even though energy independence is lost at higher doses, the material shows high sensitivity to higher energy (85 MeV) of carbon beam compared to the lower energy (65 MeV of C6+) and saturation is apparent only after 121.199 kGy. Therefore the present nanophosphor displays potential as an energy independent TLD.

  10. Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance; Grocery Stores (Revised) (Book)

    Energy Technology Data Exchange (ETDEWEB)

    Hendron, B.

    2013-07-01

    The U.S. Department of Energy developed the Advanced Energy Retrofit Guides (AERGs) to provide specific methodologies, information, and guidance to help energy managers and other stakeholders successfully plan and execute energy efficiency improvements. Detailed technical discussion is fairly limited in these guides. Instead, we emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluations of the most promising retrofit measures for each building type. A series of AERGs is under development, addressing key segments of the commercial building stock. Grocery stores were selected as one of the highest priority sectors, because they represent one of the most energy-intensive market segments.

  11. Economic Evaluation of a Solar Charged Thermal Energy Store for Space Heating

    OpenAIRE

    Melo, Manuel

    2013-01-01

    A thermal energy store corrects the misalignment of heating demand in the winter relative to solar thermal energy gathered in the summer. This thesis reviews the viability of a solar charged hot water tank thermal energy store for a school at latitude 56.25N, longitude -120.85W

  12. Exchanging and Storing Energy. Reducing Energy Demand through Heat Exchange between Functions and Temporary Storage

    Energy Technology Data Exchange (ETDEWEB)

    Sillem, E.

    2011-06-15

    As typical office buildings from the nineties have large heating and cooling installations to provide heat or cold wherever and whenever needed, more recent office buildings have almost no demand for heating due to high internal heat loads caused by people, lighting and office appliances and because of the great thermal qualities of the contemporary building envelope. However, these buildings still have vast cooling units to cool down servers and other energy consuming installations. At the same time other functions such as dwellings, swimming pools, sporting facilities, archives and museums still need to be heated most of the year. In the current building market there is an increasing demand for mixed-use buildings or so called hybrid buildings. The Science Business Centre is no different and houses a conference centre, offices, a museum, archives, an exhibition space and a restaurant. From the initial program brief it seemed that the building will simultaneously house functions that need cooling most of the year and functions that will need to be heated the majority of the year. Can this building be equipped with a 'micro heating and cooling network' and where necessary temporarily store energy? With this idea a research proposal was formulated. How can the demand for heating and cooling of the Science Business Centre be reduced by using energy exchange between different kinds of functions and by temporarily storing energy? In conclusion the research led to: four optimized installation concepts; short term energy storage in pavilion concept and museum; energy exchange between the restaurant and archives; energy exchange between the server space and the offices; the majority of heat and cold will be extracted from the soil (long term energy storage); the access heat will be generated by the energy roof; PV cells from the energy roof power all climate installations; a total energy plan for the Science Business Centre; a systematic approach for exchanging

  13. Inductive energy store (IES) technology for multi-terrawatt generators

    International Nuclear Information System (INIS)

    Sincerny, P.S.; Ashby, S.R.; Childers, F.K.; Deeney, C.; Kortbawi, D.; Goyer, J.R.; Riordan, J.C.; Roth, I.S.; Stallings, C.; Schlitt, L.

    1993-01-01

    An IES pulsed power machine has been built at Physics International Company that serves as a prototype demonstration of IES technology that is scaleable to very large TW generators. The prototype module utilizes inductive store opening switch technology for the final stage of pulse compression and is capable of driving both electron beam Bremsstrahlung loads or imploding plasma loads. Each module consists of a fast discharge Marx driving a water dielectric transfer capacitor which is command triggered to drive the inductive store section of the machine. The inductive store is discharged into the load using a plasma erosion opening switch. Data demonstrating 22% efficient operation into an electron beam diode load are presented. The system issues addressing the combining of these modules into a very large pulsed power machine are discussed

  14. TELDE thermoluminescent dosimetry system

    International Nuclear Information System (INIS)

    Shvarts, K.K.; Nemiro, E.A.; Bichev, V.R.; Gotlib, V.I.; Grant, Z.A.; Grube, M.M.; Gubatova, D.J.

    1981-01-01

    The TELDE dosimetric set designed for measurement of x- and γ- rays doses with energy more than 10 keV is described. The set consists of thermoluminescent detectors from LiF (Ca, Mg, Ti). The detectors are polycrystalline pellets with diameter 3.5+-0.3 mm and thickness 2+-0.2 mm. In the thermoluminescence detectors both the peak and integral measurement methods are realized. Apart from this the TELDE set comprises the electron unit for the pre-irradiation thermal treatment of detectors, special bones for detectors storage and transportation, devices for their package in polyethelene film and containers to wear the detectors. The TELDE set allows to perform measurements on people or animals in radiobiological experiments as well as in water, solid or porous phantoms [ru

  15. The thermoluminescent curve as parameter to compare archaeological ceramics

    International Nuclear Information System (INIS)

    Dominguez R, I.R.; Ramirez C, G.A.; Gonzalez M, P.R.; Mendoza A, D.; Martinez C, G.

    2006-01-01

    Most mineral materials, including the constituents of pottery, have the property of thermoluminescence (TL), where part of the energy from radioactive decay in the mineral is stored and later released as light upon strong heating. The intensity of emitted light as a function of temperature is the thermoluminescence glow curve. However, it is well-know the thermoluminescence glow curve form depends of several factors associates with the incident radiation and type of materials. Between the factors associated with the materials, it can be mentioned the quantity and type of crystalline phases, and quantity and type of impurities that they could be present in the material. That is to say, materials with different physicochemical characteristics will produce different thermoluminescence glow curve, although, they have been irradiated under the same conditions. In accordance with the above mentioned, it is possible to identified differences between pre hispanic ceramic belonging to a same site and other sites. In this work a discussion about advantages and disadvantages is presented. Some specific examples in ceramic artifacts belonging to the Matlatzinca and Teotihuacan cultures are included. (Author)

  16. Thermoluminescence, a universal tool for dosimetry

    International Nuclear Information System (INIS)

    Barthe, J.

    1999-01-01

    Radio-thermoluminescence is a transient light emission occurring when certain substances, which have been exposed to ionizing radiation, are heated. Under some conditions the quantity of emitted light is proportional to the absorbed dose. This linearity allows thermoluminescence to be used in various fields such as dosimetry, geology and age determination. Dosimeters based on thermoluminescence are passive, they do not require a source of energy and they can sustain high temperatures and high levels of irradiation. Thermoluminescence has been applied for determining the dose absorbed by meteorites and lunar rocks

  17. Measurement of the stored energy in the NRX reactor reflector graphite

    Energy Technology Data Exchange (ETDEWEB)

    Hilton, H. B.; Larson, E. A.G.

    1959-07-15

    With the co-operation of workers at Windscale and Harwell, whose assistance is hereby gratefully acknowledged, the stored energy content of the inner reflector graphite of NRX has been measured. Measurements made at three different elevations and at different positions through the reflector show that there is, at present, no danger to NRX from an accidental release of the energy. The energy stored in the reflector in 1958 is less by a factor five to ten than the stored energy as measured in 1953. It appears that there has been a continual release of stored energy since 1954 when, after the rehabilitation, the maximum power was raised to 40 MW. Additional thermocouples have been installed in the inner reflector, and future stored energy measurements are being scheduled. (author)

  18. Wind turbine tower for storing hydrogen and energy

    Science.gov (United States)

    Fingersh, Lee Jay [Westminster, CO

    2008-12-30

    A wind turbine tower assembly for storing compressed gas such as hydrogen. The tower assembly includes a wind turbine having a rotor, a generator driven by the rotor, and a nacelle housing the generator. The tower assembly includes a foundation and a tubular tower with one end mounted to the foundation and another end attached to the nacelle. The tower includes an in-tower storage configured for storing a pressurized gas and defined at least in part by inner surfaces of the tower wall. In one embodiment, the tower wall is steel and has a circular cross section. The in-tower storage may be defined by first and second end caps welded to the inner surface of the tower wall or by an end cap near the top of the tower and by a sealing element attached to the tower wall adjacent the foundation, with the sealing element abutting the foundation.

  19. Evaluation of thermoluminescent dosimeters (TLDs) of two different designs for beta particle and low energy photon dosimetry

    International Nuclear Information System (INIS)

    Nugent, K.J.; Ahmed, A.B.; Groer, P.G.

    1992-11-01

    The purpose of this research was to compare the response of the thermoluminescent dosimeters (TLDs) currently used at Martin Marietta Energy Systems with that of a newly designed TLD which is now under consideration. The new TLD consists of a thicker chip in element No. 3 and a thinner, more opaque mylar filter over this same element. The goals were to determine if the new (proposed) TLD would perform significantly different from the old (current) TLD when measuring dose equivalents from beta particles and low energy photons (x-rays) and to find out if changing from the old to the new design would require that modifications be made to the calibration factors currently used in the dose calculation algorithm. To accomplish these objectives, tests were performed using both types of dosimeters placed under identical conditions. Their responses were then compared and analyzed. It was concluded that the new TLDs would allow for the detection of lower levels of radiation and give more precise readouts at very low (i.e., background) levels in addition to the obvious advantages of the new design, such as, a thicker, more durable chip and a more opaque mylar. It was also determined that no adjustments to the calibration factors would be necessary in switching to the new design

  20. Energy potential in the food industry; Store energipotensialer i naeringsmiddelindustrien

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, E; Risberg, T M; Mydske, H J; Helgerud, H E

    2007-07-01

    The food industry is one of the most power consuming industries (excluding the heavy industry) and has large potential for reducing the energy consumption. This report explains the most energy efficient measures and if the injunctions are followed

  1. Spontaneous transfer of magnetically stored energy to Kinetic energy by electric double layers

    International Nuclear Information System (INIS)

    Lindberg, L.; Torven, S.

    1983-05-01

    Current disruptions are investigated in a magnetized plasma column with an inductive external electric circuit. It is found that they persist in spite of the fact that each disruption gives rise to a large inductive over-voltage. This drops off at an electric double layer formed in the plasma where most of the magnetic energy, initially stored in the circuit inductance, is released as particle energy. Simultanously as the current disrupts, the potential level at a local potential minimum in the plasma decreases. This is expected to cause the disruption by reflection of electrons. (authors)

  2. Thermoluminescent dosimetry and assessment of personal dose

    International Nuclear Information System (INIS)

    Boas, J.F.; Martin, L.J.; Young, J.G.

    1982-01-01

    Thermoluminescence is discussed in terms of the energy band structure of a crystalline solid and the trapping of charge carriers by point defects. Some general properties of thermoluminescent materials used for dosimetry are outlined, with thermoluminescence of CaSO 4 :Dy being described in detail. The energy response function and the modification of the energy response of a dosimeter by shielding are discussed. The final section covers the connection between exposure, as recorded by a TLD badge, and the absorbed dose to various organs from gamma radiation in a uranium mine; the conversion from absorbed dose to dose equivalent; and uncertainties in assessment of dose equivalent

  3. Apparatus and method for use in storing energy

    Science.gov (United States)

    Sathrum, Aaron J.

    2017-08-01

    Some embodiments provide energy storage systems that comprise: a first electrode; a second electrode; an electrolyte; the first electrode, the second electrode and the electrolyte are positioned such that the electrolyte is in contact with at least the first electrode; and a polarity reversal system electrically coupled with the first electrode and the second electrode, wherein the polarity reversal system is configured to allow the energy storage system to operate while a first polarity to charge and discharge electrical energy while operating in the first polarity, and the polarity reversal system is configured to reverse the voltage polarity across the first and second electrodes to a second polarity to allow the energy storage system to continue to operate while the second polarity is established across the first electrode and the second electrode to continue to charge and discharge electrical energy while operating in the second polarity.

  4. Fat or lean: adjustment of endogenous energy stores to predictable and unpredictable changes in allostatic load

    Science.gov (United States)

    Schultner, Jannik; Kitaysky, Alexander S.; Welcker, Jorg; Hatch, Scott

    2013-01-01

    1. The ability to store energy endogenously is an important ecological mechanism that allows animals to buffer predictable and unpredictable variation in allostatic load. The secretion of glucocorticoids, which reflects changes in allostatic load, is suggested to play a major role in the adjustment of endogenous stores to these varying conditions.

  5. Energy-Storing Structures: Composite Capacitors and Batteries

    Science.gov (United States)

    2012-07-30

    circuit board (PCB) prepreg C electrode dielectric Autoclave-processed structural capacitor • Objective: High energy density, scalable...Continued scaling (lab safety limit  100 J) – Beyond commercial FR4 prepreg  high dielectric additives, super- clean prepregging

  6. Primary power supply of repetitive pulsed intense current accelerator charged by capacitance of energy store

    International Nuclear Information System (INIS)

    Chen Jun; Yang Jianhua; Shu Ting; Zhang Jiande; Zhou Xiang; Wen Jianchun

    2008-01-01

    The primary power supply of repetitive pulsed intense current accelerator charged by capacitance of energy store is studied. The principle of primary power supply circuit and its time diagram of switches are presented. The circuit is analyzed and some expressions are got, especially, the usable voltage scope of capacitance of energy store, and the correlation between the parameters of circuit and time delay, which is between the turn-on of the charging circuit of capacitance of energy store and the circuit of recuperation. The time delay of 256 x 256 lookup table is made with the instruction of theory and the simulation of the actual parameters of circuits. The table is used by the control program to control the repetitive operating of the actual pulsed intense current accelerator. Finally, some conclusions of the primary power supply of repetitive pulsed intense current accelerator charged by capacitance of energy store are got. (authors)

  7. Thermoluminescence dosimetry environmental monitoring system

    International Nuclear Information System (INIS)

    Bortoluzzi, S.

    1989-01-01

    In this report, characteristics and performances of an environmental monitoring system with thermoluminescence dosimetry are presented. Most of the work deals with the main physical parameters necessary for measurements of ambiental dose. At the end of this report some of level doses in the environment around the site of the ENEA Center of Energy Research Salluggia (Italy) are illustrated

  8. Calibration of thermoluminescent dosimeters (LiF : Mg : Ti) at different x-ray energies

    International Nuclear Information System (INIS)

    Osman, Aziza Mobark

    1998-04-01

    In this work the distance between the x-ray target (source) and the reference point on the housing of the newly installed secondary standard dosimetry laboratory (SSDL) at Sudan Atomic Energy Commission in Soba were determined, using the inverse square law. Six x-ray qualities were used at different positions. The results showed that the distance of the source to reference point is found to be (22± 2 cm). The calibration factors for the (LIF: Mg: Ti) TLD chips with the harshow model 2000C reader was determined for x-ray energies for quality (3) (KV = 80, filtration (1mm Al +5.30 mm Cu, HVL= 0.59 mm Cu), and for quality (4) (KV = 100, filtration ( 1mm Al + 5.30 mm Cu), HVL= 1.15 mm Cu) at 3 meter distance. The calibration factors for these two qualities is found to be ( 0.1030 ± 0.0002 ), (o.1098± 0.0004 ) m Gray per nano coulomb respectively. These values m and those obtained earlier at SAEC (1996) lab, by using Sr-90 irradiator (Beta- energy 2.27 MeV) calibration factor is found to be ( 0.1030 mGray per nano coulomb), confirm that within accuracies needed at radiation protection level, ( LiF: Mg: TI ) TLDs chips can be considered as an energy independent detector in the studied energy range. It is suggested that further measurements should be carried for other energies for determination of calibration factors for the full range of energies in use. ( Author )

  9. Optimal Power Cost Management Using Stored Energy in Data Centers

    OpenAIRE

    Urgaonkar, Rahul; Urgaonkar, Bhuvan; Neely, Michael J.; Sivasubramaniam, Anand

    2011-01-01

    Since the electricity bill of a data center constitutes a significant portion of its overall operational costs, reducing this has become important. We investigate cost reduction opportunities that arise by the use of uninterrupted power supply (UPS) units as energy storage devices. This represents a deviation from the usual use of these devices as mere transitional fail-over mechanisms between utility and captive sources such as diesel generators. We consider the problem of opportunistically ...

  10. Distributed energy store powered railguns for hypervelocity launch

    Science.gov (United States)

    Maas, Brian L.; Bauer, David P.; Marshall, Richard A.

    1993-01-01

    Highly distributed power supplies are proposed as a basis for current difficulties with hypervelocity railgun power-supply compactness. This distributed power supply configuration reduces rail-to-rail voltage behind the main armature, thereby reducing the tendency for secondary armature current formation; secondary current elimination is essential for achieving the efficiencies associated with muzzle velocity above 6 km/sec. Attention is given to analytical and experimental results for two distributed energy storage schemes.

  11. Thermoluminescent dosemeters for determining the energy absorbed during X-ray radiography of the vertebral column

    International Nuclear Information System (INIS)

    Liebl, R.

    1983-01-01

    The dose and absorbed energy during normal diagnostic X-ray of various sections of the vertebral column were determined with LiF-dosemeters in a phantom. The paper describes a method to be used to determine integral doses from the dose measurements. The energy absorbed for one X-ray picture of the vertebral column is between 5 and 30 mJ. Compared to other diagnostical X-rays the quantity of the energy absorbed during X-ray of the vertebral column is rather high and is only reached by X-rays in the pelvic region. The speculations on the rate of incidence of malignent neoplasms on the basis of diagnostical X-ray of the vertebral column reveal a value of 50 per 60 x 10 6 persons. This value is likely to overestimate the risk, seems, however, to be low in comparison to other risks of every day life (traffic accident, mountainering, etc). (orig./HP) [de

  12. Experimental determination of the photon-energy dependent dose-to-water response of TLD600 and TLD700 (LiF:Mg,Ti) thermoluminescence detectors

    Energy Technology Data Exchange (ETDEWEB)

    Schwahofer, Andrea [Vivantes Clinic Neukoelln, Berlin (Germany). Dept. of Radiation Therapy; German Cancer Research Center, Heidelberg (Germany). Medical Physics in Radiation Therapy; Feist, Harald [Munich Univ. (Germany). Dept. of Radiation Therapy; Georg, Holger [PTW Freiburg (Germany). Calibration Lab.; Haering, Peter; Schlegel, Wolfgang [German Cancer Research Center, Heidelberg (Germany). Medical Physics in Radiation Therapy

    2017-05-01

    The aim of this study has been the experimental determination of the energy dependent dose-to-water response of TLD600 and TLD700 thermoluminescent detectors (Harshaw) in X-ray beams with mean photon energies from about 20 to 200 keV in comparison with {sup 60}Co gamma rays and 6 MV X-rays. Experiments were carried out in collaboration with the German secondary standard laboratory PTW Freiburg. The energy dependent relative responses of TLD600 and TLD700 thermoluminescence detectors were determined at radiation qualities between 30 kV{sub p} and 280 kV{sub p}. The overall uncertainty of the measured values was characterized by standard deviations varying from 1.2 to 3%. The present results agree with previous studies on the energy dependent dose-to-water response of TLD100. As an application example, the results were used to measure doses associated with X-ray imaging in image-guided radiotherapy.

  13. Observations on the activation energy determination through the peak temperature at the maximum in thermoluminescence (Tl) experiments

    International Nuclear Information System (INIS)

    Furetta, C.; Azorin, J.; Rivera, T.

    2003-01-01

    The aim of this work is to give, for practical purposes in routine works, an easy way for obtaining approximated values of E which can be useful for testing, in a very quick way, the stability of the trap levels corresponding to the dosimetric peak in thermoluminescent materials used for environmental, personnel and clinical dosimetry applications. Furthermore, the E values obtained with this method can be used as input data for deconvolution procedure. (Author)

  14. New kinds of energy-storing building composite PCMs for thermal energy storage

    International Nuclear Information System (INIS)

    Biçer, Alper; Sarı, Ahmet

    2013-01-01

    Graphical abstract: In this work, 10 new kinds of BCPCMs were prepared by blending of liquid xylitol pentalaurate (XPL) and xylitol pentamyristate (XPM) esters into gypsum, cement, diatomite, perlite and vermiculite. DSC results showed that the melting temperatures and energy storage capacities of the prepared BCPCMs are in range of about 40–55 °C and 31–126 J/g, respectively. TG investigations and thermal cycling test showed that the BCPCMs had good thermal endurance and thermal reliability. It can be also concluded that among the prepared 10 kinds materials, especially the BCPCMs including perlite, vermiculite, diatomite were found to better candidates for thermal energy storage applications in buildings due to the fact that they have relatively high heat storage ability. Highlights: ► New kinds BCPCMs were prepared by blending of liquid XPL and XPM esters with some building materials. ► The BCPCMs had suitable melting temperatures and energy storage capacities. ► Especially, the BCPCMs including perlite, vermiculite, diatomite were found to better candidates for thermal energy storage. - Abstract: Energy storing-composite phase change materials (PCMs) are significant means of thermal energy storage in buildings. Although several building composite PCMs (BCPCMs) have been developed in recent years, the additional investigations are still required to enrich the diversity of BCPCMs for solar heating and energy conservation applications in buildings. For this purpose, the present work is focused the preparation, characterization and determination of 10 new kinds of BCPCMs. The BCPCMs were prepared by blending of liquid xylitol pentalaurate (XPL) and xylitol pentamyristate (XPM) esters with gypsum, cement, diatomite, perlite and vermiculite as supporting matrices. The scanning electron microscopy (SEM) and Fourier Transform Infrared (FT-IR) analysis showed that the ester compounds were adsorbed uniformly into the building materials due to capillary forces

  15. The use of nested chevron rails in a distributed energy store railgun

    Science.gov (United States)

    Marshall, R. A.

    1984-03-01

    It is pointed out that the large amounts of energy required by electromagnetic launchers will necessitate that energy stores be distributed along their length. The nested chevron rail construction will make it possible for a railgun launcher to be produced in which most of the switching requirements for the launcher/energy store system will be met automatically. Each nested chevron-shaped conductor will be electrically insulated from its neighbors, and each opposing chevron pair (one on each rail) will be connected to the terminals of one energy store (Marshall, 1982). It is explained that as the projectile moves down the railgun the chevrons and associated energy stores at first are unaffected by the approach. At this time the inductors can be charged, and any other preliminary operation can be performed. When the armature comes into contact with the Nth chevron, charge begins to flow from the Nth energy storage system; it flows through one chevron, into the armature, out of the armature into the other chevron, and from that chevron back to the energy storage system.

  16. Differential calorimeter and temperature controller for stored energy measurements in irradiated alkali halides

    International Nuclear Information System (INIS)

    Delgado Martinez, L.

    1977-01-01

    The design and performance of a simple temperature-controlled differential calorimeter are presented. This system allows to measure radiation-induced stored energy in insulators, above room temperature with a differential thermal analysis method. With platelets of KC1 single crystals, the base lines obtained for T 2 T 1 (with T 2 : irradiated sample temperature and T 1 : reference sample temperature) show a smooth drift less of 0,2 degree centigree in the interval from 25 to 400 degree centigree. The discrepancy between two consecutive base lines is less than ± 0,02 degree centigree which implies a calorimeter sensitivity of about ±0,004 cal/g. This sensitivity allows to measure stored energy release in samples with a color center concentration low enough to be directly measured with a spectrophotometer so that a search for correlations among the features of the stored energy spectrum and the color center annealing can be made. (Author) 13 refs

  17. Handbook of thermoluminescence

    CERN Document Server

    Furetta, Claudio

    2010-01-01

    This second edition of the Handbook of Thermoluminescence enlarges on all the subjects which were treated in the first edition and adds further arguments, including the theory of thermoluminescent dose measurement, several examples concerning the kinetics parameters determination using various methods such as peak shape, isothermal decay, and so on. A special section is devoted to food irradiation, an important subject at the present time, and to the thermoluminescent characterization of the minerals extracted from the irradiated food. Another new section is devoted to the thermoluminescent ph

  18. Thermoluminescence in medical dosimetry

    International Nuclear Information System (INIS)

    Rivera, T.

    2011-10-01

    The dosimetry by thermoluminescence (Tl) is applied in the entire world for the dosimetry of ionizing radiations specially to personal and medical dosimetry. This dosimetry method has been very interesting for measures in vivo because the Tl dosimeters have the advantage of being very sensitive in a very small volume and they are also equivalent to tissue and they do not need additional accessories (for example, cable, electrometer, etc.) The main characteristics of the diverse Tl materials to be used in the radiation measures and practical applications are: the Tl curve, the share homogeneity, the signal stability after the irradiation, precision and exactitude, the response in function with the dose and the energy influence. In this work a brief summary of the advances of the radiations dosimetry is presented by means of the thermally stimulated luminescence and its application to the dosimetry in radiotherapy. (Author)

  19. Analysis of magnetic energy stored in superconducting coils with and without ferromagnetic inserts

    International Nuclear Information System (INIS)

    Cha, Y.S.

    1993-01-01

    Inductance and energy of superconducting coils are calculated by (1) a long-solenoid approximation, (2) a finite-element model, and (3) working formulas and tables. The results of the finite-element model compare favorably with those of the working formulas. The long-solenoid approximation overpredicts the energy and inductance compared to the other two methods. The difference decreases with increasing length-to-diameter ratio. Energy stored in a coil with a ferromagnetic insert is calculated by using a long-solenoid approximation and a finite-element model. The analysis shows that the gain in energy ratio is equal to the relative permeability of the insert (which decreases with increasing current or current density). Even though large gains can be achieved at relatively low currents, the energy level itself is too low. The stored energy increases with current, but the gain decreases with increasing current because relative permeability decreases. If a coil with a diameter of 0.3 m and a length of 0.3 m is required to store 10 kJ of energy, the current density must equal 4000 A/cm 2 . The gain in energy ratio is equal to 2.55 when the insert is used

  20. Energy stores are not altered by long-term partial sleep deprivation in Drosophila melanogaster.

    Directory of Open Access Journals (Sweden)

    Susan T Harbison

    2009-07-01

    Full Text Available Recent human studies reveal a widespread association between short sleep and obesity. Two hypotheses, which are not mutually exclusive, might explain this association. First, genetic factors that reduce endogenous sleep times might also impact energy stores, an assertion that we confirmed in a previous study. Second, metabolism may be altered by chronic partial sleep deprivation. Here we address the second assertion by measuring the impact of long-term partial sleep deprivation on energy stores using Drosophila as a model. We subjected flies to long-term partial sleep deprivation via two different methods: a mechanical stimulus and a light stimulus. We then measured whole-body triglycerides and glycogen, two important sources of energy for the fly, and compared them to un-stimulated controls. We also measured changes in energy stores in response to a random circadian clock shift. Sex and line-dependent alterations in glycogen and/or triglyceride levels occurred in response to the circadian clock shift and in flies subjected to a single night of sleep deprivation using light. Thus, consistent with previous studies, our findings suggest that acute sleep loss and changes to the circadian clock can alter metabolism. Significant changes in energy stores were also observed when flies were subjected to chronic sleep loss via the mechanical stimulus, although not the light stimulus. Interestingly, mechanical stimulation resulted in the same change in energy stores even when it was not associated with sleep deprivation, suggesting that the changes are caused by stress rather than sleep loss. These findings emphasize the importance of taking stress into account when evaluating the relationship between sleep loss and metabolism.

  1. Thermoluminescent dosimeter system

    International Nuclear Information System (INIS)

    Felice, P.E.; Gonzalez, J.L.; Seidel, J.G.

    1979-01-01

    An improved thermoluminescent dosimeter system and apparatus for sensing alpha particle emission is described. A thermoluminescent body is sealed between a pair of metallized plastic films. The dosimeter is mounted within a protective inverted cup or a tube closed at one end, which is disposed in a test hole for exposure to radioactive radon gas which is indicaive of uranium deposits

  2. Stored Energy of Coupled Electric and Magnetic Currents and the Lower Bound on Q

    DEFF Research Database (Denmark)

    Kim, Oleksiy S.

    2015-01-01

    —New expressions for the stored energy and radiated power of an arbitrary combination of electric and magnetic currents in free space are presented. These expressions enable the calculation of the fundamental lower bound on Q for arbitraryshaped electrically small antennas of finite size....

  3. Power-to-Gas: storing surplus electrical energy. A design study

    NARCIS (Netherlands)

    Buchholz, O.S.; van der Ham, Aloysius G.J.; Veneman, Rens; Brilman, Derk Willem Frederik; Kersten, Sascha R.A.

    2014-01-01

    In this work a conceptual design of a Power-to-Gas (PtG) process for storing electrical energy in form of synthetic natural gas (SNG) of gas grid quality H is presented. The combination with a conventional lignite fired power plant (LPP) was investigated for possible improvement of its economic

  4. A Bench Measurement of the Energy Loss of a Stored Beam to a Cavity

    Energy Technology Data Exchange (ETDEWEB)

    Sands, M; Rees, J.; /SLAC

    2016-12-19

    A rather simple electronic bench experiment is proposed for obtaining a measure of the impulse energy loss of a stored particle bunch to an rf cavity or other vacuum-chamber structure--the so-called "cavity radiation". The proposed method is analyzed in some detail.

  5. Low stored energy 100 kV regulator for ion sources at LANSCE

    International Nuclear Information System (INIS)

    Jacobson, E.G.; Haffner, R.L.; Ingalls, W.B.; Meyer, B.J.; Stelzer, J.E.

    1998-01-01

    To minimize accelerating column damage caused by uncontrolled energy release during arc-downs, it is desirable to minimize the available stored electrical energy. For the Los Alamos Neutron Science Center (LANSCE) H - ion sources, the stored energy includes, in addition to the charge in the power supply output capacitance, the charge on the electronics racks. They are supported and insulated from ground by PVC pipe and have a capacitance to ground of approximately 900 pf. In 1988 (LANSCE) personnel designed a high-voltage current source using a low-stored-energy power supply and planar triode with the goal of eliminating uncontrolled release of charge stored in the power supply. Construction and testing were performed intermittently as resources permitted until 1993. When work on the Short Pulse Spallation Source (SPSS) started on the LANSCE Ion Source Test Stand (ISTS) it was recognized that a higher current power supply would be needed and work resumed on the regulator circuitry. A 120 kV power supply having low output capacitance, and a planar triode have been used to supply 40 mA, 120 Hz, 12% duty-factor current for the ISTS beam. The triode's cathode current is controlled by circuitry operating both at power-supply voltage level and at ground level via a fiber optic link. Voltage droop is approximately 600 V during the 1 ms beam pulse. The authors present the status of the regulator and its special challenges

  6. Fascicles and the interfascicular matrix show decreased fatigue life with ageing in energy storing tendons.

    Science.gov (United States)

    Thorpe, Chavaunne T; Riley, Graham P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2017-07-01

    Tendon is composed of rope-like fascicles bound together by interfascicular matrix (IFM). The IFM is critical for the function of energy storing tendons, facilitating sliding between fascicles to allow these tendons to cyclically stretch and recoil. This capacity is required to a lesser degree in positional tendons. We have previously demonstrated that both fascicles and IFM in energy storing tendons have superior fatigue resistance compared with positional tendons, but the effect of ageing on the fatigue properties of these different tendon subunits has not been determined. Energy storing tendons become more injury-prone with ageing, indicating reduced fatigue resistance, hence we tested the hypothesis that the decline in fatigue life with ageing in energy storing tendons would be more pronounced in the IFM than in fascicles. We further hypothesised that tendon subunit fatigue resistance would not alter with ageing in positional tendons. Fascicles and IFM from young and old energy storing and positional tendons were subjected to cyclic fatigue testing until failure, and mechanical properties were calculated. The results show that both IFM and fascicles from the SDFT exhibit a similar magnitude of reduced fatigue life with ageing. By contrast, the fatigue life of positional tendon subunits was unaffected by ageing. The age-related decline in fatigue life of tendon subunits in energy storing tendons is likely to contribute to the increased risk of injury in aged tendons. Full understanding of the mechanisms resulting in this reduced fatigue life will aid in the development of treatments and interventions to prevent age-related tendinopathy. Understanding the effect of ageing on tendon-structure function relationships is crucial for the development of effective preventative measures and treatments for age-related tendon injury. In this study, we demonstrate for the first time that the fatigue resistance of the interfascicular matrix decreases with ageing in energy

  7. Energy saving effects of wireless sensor networks: a case study of convenience stores in Taiwan.

    Science.gov (United States)

    Chen, Chih-Sheng; Lee, Da-Sheng

    2011-01-01

    Wireless sensor network (WSN) technology has been successfully applied to energy saving applications in many places, and plays a significant role in achieving power conservation. However, previous studies do not discuss WSN costs and cost-recovery. The application of WSNs is currently limited to research and laboratory experiments, and not mass industrial production, largely because business owners are unfamiliar with the possible favorable return and cost-recovery on WSN investments. Therefore, this paper focuses on the cost-recovery of WSNs and how to reduce air conditioning energy consumption in convenience stores. The WSN used in this study provides feedback to the gateway and adopts the predicted mean vote (PMV) and computational fluid dynamics (CFD) methods to allow customers to shop in a comfortable yet energy-saving environment. Four convenience stores in Taipei have used the proposed WSN since 2008. In 2008, the experiment was initially designed to optimize air-conditioning for energy saving, but additions to the set-up continued beyond 2008, adding the thermal comfort and crowds peak, off-peak features in 2009 to achieve human-friendly energy savings. Comparison with 2007 data, under the same comfort conditions, shows that the power savings increased by 40% (2008) and 53% (2009), respectively. The cost of the WSN equipment was 500 US dollars. Experimental results, including three years of analysis and calculations, show that the marginal energy conservation benefit of the four convenience stores achieved energy savings of up to 53%, recovering all costs in approximately 5 months. The convenience store group participating in this study was satisfied with the efficiency of energy conservation because of the short cost-recovery period.

  8. Modeling the transmitted and stored energy in multilayer protective clothing under low-level radiant exposure

    International Nuclear Information System (INIS)

    Su, Yun; He, Jiazhen; Li, Jun

    2016-01-01

    Highlights: • A numerical model from heating source to skin tissues through multilayer fabric system is developed. • The numerical model is comprehensively validated with experimental data. • The model is used to investigate the relationship between the transmitted and stored energy and the influencing factors. - Abstract: A finite difference model was introduced to simulate the transmitted and stored energy in firefighters' protective clothing exposed to low-level thermal radiation. The model domain consists of a three-layer fire-resistant fabric system (outer shell, moisture barrier, and thermal liner), the human skin, and the air gap between clothing and the skin. The model accounted for the relationship between the transmitted heat during the exposure and the discharged heat during the cooling-down period. The numerical model predictions were compared with experimental data. Additionally, the parameters that affect the transmitted and stored energy of protective clothing were investigated. The results demonstrate that for the typical multilayer firefighter protective clothing, the transmitted heat during exposure and the discharged heat after exposure totally determine the skin burn under low-level heat exposure, especially for third-degree skin burns. The findings obtained in this study can be used to engineer fabric systems that provide better protection for the stored thermal burn.

  9. Thermal annealing of high dose radiation induced damage at room temperature in alkali halides. Stored energy, thermoluminiscence and colouration

    International Nuclear Information System (INIS)

    Delgado, L.

    1980-01-01

    The possible relation between stored energy, thermoluminiscence and colour centre annealing in gamma and electron irradiated alkali halides is studied. Thermoluminiscence occurs at temperature higher than the temperature at which the main stored energy peak appears. No stored energy release is detected in additively coloured KCl samples. Plastic deformation and doping with Ca and Sr induce a stored energy spectrum different from the spectrum observed in pure and as cleaved samples, but the amount of stored energy does not change for a given irradiation dose. Capacity of alkali halides to sotore energy by irradiation increases as the cation size decreases. It appears that most of the observed release is not related to annealing processes of the radiation induced anion Frenkel pairs. The existence of damage in the cation sublattice with which this energy release might be related is considered. (auth.)

  10. Thermal activation energies and peak temperatures in thermoluminescence of LiF (Mg, Ti) and CaF2:Mn at low temperatures

    International Nuclear Information System (INIS)

    Jain, V.K.; Jahan, M.S.

    1987-01-01

    Low temperature thermoluminescence (TL) of LiF (TLD-100) and CaF 2 :Mn is studied. The TLD-100 is dosimetry grade LiF manufactured by Harshaw-Filtrol Partnership. It is believed that it contains about 200 ppm Mg and 7 ppm Ti as impurities. In each case the glow curve shows several peaks. Some of these peaks are quite strong and develop with dose. Others are weak. Kinetic parameters are calculated for the former using the initial rise method and Chen's modified formula. The two sets of values are found to be different. Some authors have suggested empirical formulae connecting peak temperature, T m , and activation energy, E. The empirical relations are tried for the values of E calculated, as well as those available in literature (for T m above room temperature). It is found that a fairly reasonable relation existed between E and T m . (author)

  11. A Dynamic Non Energy Storing Guidance Constraint with Motion Redirection for Robot Assisted Surgery

    Science.gov (United States)

    2016-12-01

    move during the operation. Robot -assisted beating heart surgery is an example of procedures that can benefit from dynamic constraints. Their...A Dynamic Non-Energy-Storing Guidance Constraint with Motion Redirection for Robot -Assisted Surgery Nima Enayati, Eva C. Alves Costa, Giancarlo...Momi, and G. Ferrigno, “Haptics in Robot -Assisted Surgery : Challenges and Benefits,” IEEE Rev. Biomed. Eng., 2016. [2] L. B. Rosenberg, “Virtual

  12. Equipment for observing thermoluminescence

    International Nuclear Information System (INIS)

    Sette Camara, Alexandre; Cogneau, Michel; Ristori, Christian; Vargas, Jose Israel

    1971-06-01

    A detailed description is given of an apparatus for investigating thermoluminescence properties. Chopping of the emitted light and subsequent amplification of the electric signal derived led to high stability and sensitivity [fr

  13. Uncertainties in modeling and scaling in the prediction of fuel stored energy and thermal response

    International Nuclear Information System (INIS)

    Wulff, W.

    1987-01-01

    The steady-state temperature distribution and the stored energy in nuclear fuel elements are computed by analytical methods and used to rank, in the order of importance, the effects on stored energy from statistical uncertainties in modeling parameters, in boundary and in operating conditions. An integral technique is used to calculate the transient fuel temperature and to estimate the uncertainties in predicting the fuel thermal response and the peak clad temperature during a large-break loss of coolant accident. The uncertainty analysis presented here is an important part of evaluating the applicability, the uncertainties and the scaling capabilities of computer codes for nuclear reactor safety analyses. The methods employed in this analysis merit general attention because of their simplicity. It is shown that the blowdown peak is dominated by fuel stored energy alone or, equivalently, by linear heating rate. Gap conductance, peaking factors and fuel thermal conductivity are the three most important fuel modeling parameters affecting peak clad temperature uncertainty. 26 refs., 10 figs., 6 tabs

  14. Preparation of thermoluminescent materials

    International Nuclear Information System (INIS)

    1976-01-01

    Thermoluminescent materials have been found to be suitable for measuring long term exposures to low level ionizing radiation. Oxyhalides of lanthanum, gadolinium and yttrium, including the oxychlorides and oxybromides are activated with terbium and have been found to be most efficient oxygendominated phosphors having thermoradiant efficiencies with excitation by low level ionizing radiation. Thermoluminescence response increases when the previous materials have hafnium and zirconium additives

  15. An astrophysical engine that stores gravitational work as nuclear Coulomb energy

    Science.gov (United States)

    Clayton, Donald

    2014-03-01

    I describe supernovae gravity machines that store large internal nuclear Coulomb energy, 0.80Z2A- 1 / 3MeV per nucleus. Excess of it is returned later by electron capture and positron emission. Decay energy manifests as (1) observable gamma-ray lines (2) light curves of supernovae (3) chemical energy of free carbon dissociated from CO molecules (4) huge abundances of radiogenic daughters. I illustrate by rapid silicon burning, a natural epoch in SN II. Gravitational work produces the high temperatures that photoeject nucleons and alpha particles from heavy nuclei. These are retained by other nuclei to balance photoejection rates (quasiequilibrium). The abundance distribution adjusts slowly as remaining abundance of Z = N 28Si decomposes, so p, n, α recaptures hug the Z = N line. This occurs in milliseconds, too rapidly for weak decay to alter bulk Z/N ratio. The figure displays those quasiequilibrium abundances color-coded to their decays. Z = N = 2k nuclei having k 10 are radioactive owing to excess Coulomb energy. Weak decays radiate that excess energy weeks later to fuel the four macroscopic energetic phenomena cited. How startling to think of the Coulomb nuclear force as storing cosmic energy and its weak decay releasing macroscopic activation to SNII.

  16. Experimental Study on Conversion of Stored Thermal Energy to Mechanical Work in FCI

    International Nuclear Information System (INIS)

    Fujii-e, Y.; Kondo, S.; Mivazaki, K.

    1976-01-01

    In the present study the process how the thermal energy stored in the coolant should be converted into the mechanical work is emphasized as well as the generation of pressure waves, eliminating the complicated problems involved in FCI, such as fragmentation, heat transfer from molten fuel to coolant, etc. A simulation experiment has been performed in a small scale vertical channel using stagnant potassium. Large superheat inherent in liquid metals was utilized as the method to accumulate the thermal energy. The following experimental parameters were chosen to examine their effects on the energy conversion ratio: the heat flux, the cover gas pressure, the liquid column length, the temperature of the upper unheated region and the incipient boiling superheat (corresponding to the stored thermal energy). The results are summarized that the conversion ratio from thermal to kinetic energies has increasing trends with increases of the incipient boiling superheat, the cover gas pressure and the temperature of upper unheated region, ranging over 0.02-0.75% in the present experiment. The important conclusions of the present experiment are summarized as follows. The thermal to kinetic energy conversion ratio n k ranges over 0.02-0.75 % for ΔT s = 10-150 deg.C, estimating from the maximum velocity measured. The thermal to mechanical work conversion ratio n w ranges over 0.14-5.6%. The effect of the heat flux on the both conversion ratios is small within the range covered by the present experiment (g≤133 W/cm 2 ). The effect of the liquid column length is not presented. The thermal to kinetic energy conversion ratio increases with the incipient boiling superheat which corresponds to the stored thermal energy in the present experiment. The both conversion ratio decrease with a decrease of the cover gas pressure. This is attributable to the thermal contact in the upper unheated region. The both conversion ratios increase with an increase in the temperature of the upper

  17. Activation energies from blue- and red-thermoluminescence (TL) of quartz grains and mean lives of trapped electrons related to natural red-TL

    International Nuclear Information System (INIS)

    Hashimoto, T.; Kojima, M.; Shirai, N.; Ichino, M.

    1993-01-01

    A three-dimensional representation of thermoluminescence (TL) spectra has been established by employing an image intensifier unit combined with a simple spectrophotometer and a microcomputer. By means of this TL spectrometric system, natural quartz grains could be distinguished as either blue-and/or red-TL ones. In these blue- and red-TL wavelength regions, activation energies from artificially irradiated quartz grains are evaluated using a repeated initial rise method. An apparent difference of activation energies in the two colorations was observed for dune sands presumably originating from different quartz sources. On the other hand, quartz grains extracted from a volcanic ash sediment showed completely similar activation energies in both TL color regions over all temperatures. Subsequently, the kinetic parameters were derived for the naturally occurring red-TL, possessing an apparent single peak around 340 o C, from volcanically originating quartz grains by fitting a theoretical equation to the glow curves, after evaluating activation energies. On the basis of the empirical kinetic parameters, the mean life of trapped electrons relating to a main 340 o C peak has been proved to be 1 million years, and a secondary weak peak around 280 o C in the natural red-TL glow curve has been confirmed. (author)

  18. PCM/wood composite to store thermal energy in passive building envelopes

    Science.gov (United States)

    Barreneche, C.; Vecstaudza, J.; Bajare, D.; Fernandez, A. I.

    2017-10-01

    The development of new materials to store thermal energy in a passive building system is a must to improve the thermal efficiency by thermal-regulating the indoor temperatures. This fact will deal with the reduction of the gap between energy supply and energy demand to achieve thermal comfort in building indoors. The aim of this work was to test properties of novel PCM/wood composite materials developed at Riga Technical University. Impregnation of PCM (phase change material) in wood increases its thermal mass and regulates temperature fluctuations during day and night. The PCM used are paraffin waxes (RT-21 and RT-27 from Rubitherm) and the wood used was black alder, the most common wood in Latvia. The PCM distribution inside wood sample has been studied as well as its thermophysical, mechanical and fire reaction properties. Developed composite materials are promising in the field of energy saving in buildings.

  19. SIMULATION RESULTS OF RUNNING THE AGS MMPS, BY STORING ENERGY IN CAPACITOR BANKS.

    Energy Technology Data Exchange (ETDEWEB)

    MARNERIS, I.

    2006-09-01

    The Brookhaven AGS is a strong focusing accelerator which is used to accelerate protons and various heavy ion species to equivalent maximum proton energy of 29 GeV. The AGS Main Magnet Power Supply (MMPS) is a thyristor control supply rated at 5500 Amps, +/-go00 Volts. The peak magnet power is 49.5 Mwatts. The power supply is fed from a motor/generator manufactured by Siemens. The motor is rated at 9 MW, input voltage 3 phase 13.8 KV 60 Hz. The generator is rated at 50 MVA its output voltage is 3 phase 7500 Volts. Thus the peak power requirements come from the stored energy in the rotor of the motor/generator. The rotor changes speed by about +/-2.5% of its nominal speed of 1200 Revolutions per Minute. The reason the power supply is powered by the Generator is that the local power company (LIPA) can not sustain power swings of +/- 50 MW in 0.5 sec if the power supply were to be interfaced directly with the AC lines. The Motor Generator is about 45 years old and Siemens is not manufacturing similar machines in the future. As a result we are looking at different ways of storing energy and being able to utilize it for our application. This paper will present simulations of a power supply where energy is stored in capacitor banks. The simulation program used is called PSIM Version 6.1. The control system of the power supply will also be presented. The average power from LIPA into the power supply will be kept constant during the pulsing of the magnets at +/-50 MW. The reactive power will also be kept constant below 1.5 MVAR. Waveforms will be presented.

  20. Stored Energy and Quality Factor of Spherical Wave Functions–in Relation to Spherical Antennas With Material Cores

    DEFF Research Database (Denmark)

    Hansen, Troels V.; Kim, Oleksiy S.; Breinbjerg, Olav

    2012-01-01

    wave, the excitation coefficients for the internal and external spherical waves, the radiated power, the internal and external stored electric and magnetic energies, the difference of total electric and total magnetic energy, the cavity and radiating resonance conditions, and the quality factor. We...... investigate the variation of the internal/external and electric/magnetic stored energies with the electrical size of the antenna to study their relative significance for the quality factor....

  1. New thermoluminescence techniques for mineral exploration

    International Nuclear Information System (INIS)

    Levy, P.W.; Holmes, R.J.; Ypma, P.J.; Chen, C.C.; Swiderski, H.S.

    1977-01-01

    The thermoluminescence of carbonate host rock in the vicinity of known lead-zinc and lead-zinc-fluorite mineralization was reexamined for possible development as an exploration technique. The measurements were made with equipment for determining the thermoluminescence spectrum at closely spaced temperature intervals. Radiation-induced thermoluminescence was also measured. Samples were studied from five localities in Mexico, Southwest Africa, and the United States. Four thermoluminescence properties were found to vary with ''distance-from-ore'' in a systematic manner. These include the glow peak intensity and temperature and the emission spectrum peak energy and full width at half-maximum. For example, in both limestone and dolomite, the high-temperature glow peak intensities are low or negligible within the ore and as the distance from the contact increases the intensity rises rapidly to a maximum, or maxima, and then decreases irregularly to constant value slightly above that in the ore. Depending on the thickness of the ore, the thermoluminescence characteristics associated with the mineralization extended from ten to a hundred or so meters from the ore host rock contact. 5 figures

  2. The efficiency, energy intensity and visual impact of the accent lighting in the retail grocery stores

    Directory of Open Access Journals (Sweden)

    Ľudmila Nagyová

    2014-11-01

    Full Text Available Over the last few years, topics of displaying, presentation, lighting, energy saving and issues related to the environment while selling the fresh food (fruits, vegetable, bakery products, meat are becoming an important matter among traders. However, just bigger companies with transnational capital have devoted their attention to this issue yet. Generally, the energy costs make up 70% of operating costs in retail stores where the cooling system and lighting are the most energy consuming. Accent lighting in modern retails is largely involved in the overall design and atmosphere in shops and plays a crucial role in presenting the goods as well. Using of accent lighting can draw the customer's attention to a specific part of the sales area and achieve the overall harmonization in the store. With the rational using of combination of energy saving and effective accent lighting retailers can achieve not only attractive presentation of displayed products but also appreciable savings in the operation of their stores. It is the only factor that can be exactly measured and controlled. Using a Colour and Lux Meters we found out the intensity and color temperature of accent lighting used in domestic and foreign retail chains for the different kinds of fresh food products. Based on the obtained values we have compiled graphs, which are showing visual comfort. We also identified different types of accent lighting, which we assigned to their impact on emotional involvement of consumers. The starting points were the tests we conducted in simulated laboratory conditions. While searching of a compromise between effective and energy efficient accent lighting we take into consideration consumers' emotional response as well as the annual electricity consumption of different types of light sources. At the end we recommend options for energy-efficient, effective and spectacular lighting while using the optimal number of light sources and their logical organization

  3. Thermoluminescence albedo-neutron dosimetry

    International Nuclear Information System (INIS)

    Strand, T.; Storruste, A.

    1986-10-01

    The report discusses neutron detection with respect to dosimetry and compares different thermoluminescent dosimetry materials for neutron dosimetry. Construction and calibration of a thermoluminescence albedo neutron dosemeter, developed by the authors, is described

  4. Recent research into thermoluminescent dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, T [National Inst. of Radiological Sciences, Chiba (Japan)

    1979-04-01

    The trend of basic research in thermoluminescent dosimetry (TLD), the results, and developing fields in which it can be applied are reported. This trend is outlined from the viewpoint fields of application, a new trend in TLD readers, the conditions of development of new photogenic substances, and research in the radiation characteristics of photogenic substances (radiosensitivity to particle rays and ultraviolet rays, dose rate dependence, temperature dependence at irradiation, and ..gamma.. ray energy dependence). Utilization of TLD in the medical field for measurement of environmental radiation and as a monitor for workers exposed to radiation is discussed. An international comparison of dose was necessary in order to prove its universal validity.

  5. Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for 125I and 103Pd brachytherapy sources relative to 60Co

    International Nuclear Information System (INIS)

    Reed, J. L.; Micka, J. A.; Culberson, W. S.; DeWerd, L. A.; Rasmussen, B. E.; Davis, S. D.

    2014-01-01

    Purpose: To determine the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters (TLD-100) for 125 I and 103 Pd brachytherapy sources relative to 60 Co. Methods: LiF:Mg,Ti TLDs were irradiated with low-energy brachytherapy sources and with a 60 Co teletherapy source. The brachytherapy sources measured were the Best 2301 125 I seed, the OncoSeed 6711 125 I seed, and the Best 2335 103 Pd seed. The TLD light output per measured air-kerma strength was determined for the brachytherapy source irradiations, and the TLD light output per air kerma was determined for the 60 Co irradiations. Monte Carlo (MC) simulations were used to calculate the dose-to-TLD rate per air-kerma strength for the brachytherapy source irradiations and the dose to TLD per air kerma for the 60 Co irradiations. The measured and MC-calculated results for all irradiations were used to determine the TLD intrinsic energy dependence for 125 I and 103 Pd relative to 60 Co. Results: The relative TLD intrinsic energy dependences (relative to 60 Co) and associated uncertainties (k = 1) were determined to be 0.883 ± 1.3%, 0.870 ± 1.4%, and 0.871 ± 1.5% for the Best 2301 seed, OncoSeed 6711 seed, and Best 2335 seed, respectively. Conclusions: The intrinsic energy dependence of TLD-100 is dependent on photon energy, exhibiting changes of 13%–15% for 125 I and 103 Pd sources relative to 60 Co. TLD measurements of absolute dose around 125 I and 103 Pd brachytherapy sources should explicitly account for the relative TLD intrinsic energy dependence in order to improve dosimetric accuracy

  6. Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for 125I and 103Pd brachytherapy sources relative to 60Co.

    Science.gov (United States)

    Reed, J L; Rasmussen, B E; Davis, S D; Micka, J A; Culberson, W S; DeWerd, L A

    2014-12-01

    To determine the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters (TLD-100) for (125)I and (103)Pd brachytherapy sources relative to (60)Co. LiF:Mg,Ti TLDs were irradiated with low-energy brachytherapy sources and with a (60)Co teletherapy source. The brachytherapy sources measured were the Best 2301 (125)I seed, the OncoSeed 6711 (125)I seed, and the Best 2335 (103)Pd seed. The TLD light output per measured air-kerma strength was determined for the brachytherapy source irradiations, and the TLD light output per air kerma was determined for the (60)Co irradiations. Monte Carlo (MC) simulations were used to calculate the dose-to-TLD rate per air-kerma strength for the brachytherapy source irradiations and the dose to TLD per air kerma for the (60)Co irradiations. The measured and MC-calculated results for all irradiations were used to determine the TLD intrinsic energy dependence for (125)I and (103)Pd relative to (60)Co. The relative TLD intrinsic energy dependences (relative to (60)Co) and associated uncertainties (k = 1) were determined to be 0.883 ± 1.3%, 0.870 ± 1.4%, and 0.871 ± 1.5% for the Best 2301 seed, OncoSeed 6711 seed, and Best 2335 seed, respectively. The intrinsic energy dependence of TLD-100 is dependent on photon energy, exhibiting changes of 13%-15% for (125)I and (103)Pd sources relative to (60)Co. TLD measurements of absolute dose around (125)I and (103)Pd brachytherapy sources should explicitly account for the relative TLD intrinsic energy dependence in order to improve dosimetric accuracy.

  7. Globally optimal superconducting magnets part I: minimum stored energy (MSE) current density map.

    Science.gov (United States)

    Tieng, Quang M; Vegh, Viktor; Brereton, Ian M

    2009-01-01

    An optimal current density map is crucial in magnet design to provide the initial values within search spaces in an optimization process for determining the final coil arrangement of the magnet. A strategy for obtaining globally optimal current density maps for the purpose of designing magnets with coaxial cylindrical coils in which the stored energy is minimized within a constrained domain is outlined. The current density maps obtained utilising the proposed method suggests that peak current densities occur around the perimeter of the magnet domain, where the adjacent peaks have alternating current directions for the most compact designs. As the dimensions of the domain are increased, the current density maps yield traditional magnet designs of positive current alone. These unique current density maps are obtained by minimizing the stored magnetic energy cost function and therefore suggest magnet coil designs of minimal system energy. Current density maps are provided for a number of different domain arrangements to illustrate the flexibility of the method and the quality of the achievable designs.

  8. Effect of particle size on activation energy and peak temperature of the thermoluminescence glow curve of undoped ZnS nanoparticles.

    Science.gov (United States)

    Chandra, B P; Chandrakar, Raju Kumar; Chandra, V K; Baghel, R N

    2016-03-01

    This paper reports the effect of particle size on the thermoluminescence (TL) of undoped ZnS nanoparticles. ZnS nanoparticles were prepared using a chemical precipitation method in which mercaptoethanol was used as the capping agent. The nanoparticles were characterized by X-ray diffraction, field emission gun-scanning electron microscopy and high-resolution transmission electron microscopy. When the concentrations of mercaptoethanol used are 0, 0.005, 0.01, 0.015, 0.025, 0.040 and 0.060 M, the sizes of the nanoparticles are 2.86, 2.81, 2.69, 2.40, 2.10, 1.90 and 1.80 nm, respectively. Initially, the TL intensity of UV-irradiated ZnS nanoparticles increases with temperature, attains a peak value Im for a particular temperature Tm, and then decreases with further increases in temperature. The values of both Im and Tm increase with decreasing nanoparticle size. Whereas the activation energy decreases slightly with decreasing nanoparticle size, the frequency factor decreases significantly as the nanoparticle size is reduced. The order of kinetics for the TL glow curve of ZnS nanoparticles is 2. Expressions are derived for the dependence of activation energy (Ea) and Tm on nanoparticle size, and good agreement is found between the experimental and theoretical results. Copyright © 2015 John Wiley & Sons, Ltd.

  9. Thermoluminescence dating of pottery

    International Nuclear Information System (INIS)

    Higashimura, Takenobu; Ichikawa, Yoneta.

    1978-01-01

    This report is divided into two parts. The first half describes on the history of thermoluminescence dating, and the latter half, the principle and measurement examples. It was in late 1955 that the measurement of radiation dose using thermoluminescence began. The method to thermoluminescence dating was developed when it was found that most natural stones emit the thermoluminescence. About Greek earthen wares, the study of which was presented in 1961 by G. Kennedy of University of California, the dating was able to be made within the standard deviation of 10%. Since then, this dating method progressed rapidly, and a number of laboratories are now forwarding the investigation. In the samples of natural materials, intensity of thermoluminescence I is proportional to natural radiation dose D which has been absorbed by the samples, i.e. I = kD, where k is the susceptibility of thermoluminescence of the samples. Since k is different in each sample, D can be determined by irradiating the sample with β or γ ray of known dose D 0 , measuring its luminescence I 0 , and eliminating k through these two equations, because i 0 = kD 0 . Next, if t is assumed to be the time passed since a pottery was made, D is expressed as Rt, where R is the natural radiation dose per year absorbed by the pottery. Thus t is determined if R is known. The report describes on the method of measuring R. As an example, the results of measurement of the potteries excavated at Iwakura remains, Yorikura, Taishaku-kyo, are listed. Results by 14 C dating are also described for reference. (Wakatsuki, Y.)

  10. Thermoluminescence from natural calcites

    International Nuclear Information System (INIS)

    Calderon, T.; Jaque, F.; Coy-yll, R.

    1984-01-01

    Thermoluminescence (TL) as well as absorption and EPR spectra of x-irradiated natural calcites have been obtained. Irradiation produces UV absorption bands and a decrease of the Mn 2+ EPR spectrum. A correlation of each TL peak with the bleaching steps of UV absorption bands and the recovering in intensity of the Mn 2+ EPR spectrum has been found. These experimental results support a new model for the radiation damage and thermoluminescence process in calcites. The main point in this model is that holes become trapped at impurities, and the electrons are trapped at dislocations in the form of CO 3 3- . (author)

  11. Fuzzy droop control loops adjustment for stored energy balance in distributed energy storage system

    DEFF Research Database (Denmark)

    Aldana, Nelson Leonardo Diaz; Wu, Dan; Dragicevic, Tomislav

    2015-01-01

    system, in order to smooth the variations at the prime energy generator. In this paper, a decentralized strategy based on fuzzy logic is proposed in order to balance the state of charge of distributed energy storage systems in lowvoltage three phase AC microgrid. The proposed method weights the action...

  12. The thermoluminescent curve as parameter to compare archaeological ceramics; La curva termoluminiscente como parametro para comparar ceramica arqueologica

    Energy Technology Data Exchange (ETDEWEB)

    Dominguez R, I.R.; Ramirez C, G.A. [Centro INAH Estado de Mexico. Morelos Ote. 502, Col. San Sebastian, 50090 Toluca, Estado de Mexico (Mexico); Gonzalez M, P.R.; Mendoza A, D. [lNIN, Carr. Mexico-Toluca S/N, La Marquesa, 52750 Ocoyoacac, Estado de Mexico (Mexico); Martinez C, G. [Coordinacion Nacional de Conservacion del Patrimonio Cultural, INAH, Mexico D.F. (Mexico)

    2006-07-01

    Most mineral materials, including the constituents of pottery, have the property of thermoluminescence (TL), where part of the energy from radioactive decay in the mineral is stored and later released as light upon strong heating. The intensity of emitted light as a function of temperature is the thermoluminescence glow curve. However, it is well-know the thermoluminescence glow curve form depends of several factors associates with the incident radiation and type of materials. Between the factors associated with the materials, it can be mentioned the quantity and type of crystalline phases, and quantity and type of impurities that they could be present in the material. That is to say, materials with different physicochemical characteristics will produce different thermoluminescence glow curve, although, they have been irradiated under the same conditions. In accordance with the above mentioned, it is possible to identified differences between pre hispanic ceramic belonging to a same site and other sites. In this work a discussion about advantages and disadvantages is presented. Some specific examples in ceramic artifacts belonging to the Matlatzinca and Teotihuacan cultures are included. (Author)

  13. Storing energy for cooling demand management in tropical climates: A techno-economic comparison between different energy storage technologies

    International Nuclear Information System (INIS)

    Comodi, Gabriele; Carducci, Francesco; Sze, Jia Yin; Balamurugan, Nagarajan; Romagnoli, Alessandro

    2017-01-01

    This paper addresses the role of energy storage in cooling applications. Cold energy storage technologies addressed are: Li-Ion batteries (Li-Ion EES), sensible heat thermal energy storage (SHTES); phase change material (PCM TES), compressed air energy storage (CAES) and liquid air energy storage (LAES). Batteries and CAES are electrical storage systems which run the cooling systems; SHTES and PCM TES are thermal storage systems which directly store cold energy; LAES is assessed as a hybrid storage system which provides both electricity (for cooling) and cold energy. A hybrid quantitative-qualitative comparison is presented. Quantitative comparison was investigated for different sizes of daily cooling energy demand and three different tariff scenarios. A techno-economic analysis was performed to show the suitability of the different storage systems at different scales. Three parameters were used (Pay-back period, Savings-per-energy-unit and levelized-cost-of-energy) to analyze and compare the different scenarios. The qualitative analysis was based on five comparison criteria (Complexity, Technology Readiness Level, Sustainability, Flexibility and Safety). Results showed the importance of weighing the pros and cons of each technology to select a suitable cold energy storage system. Techno-economic analysis highlighted the fundamental role of tariff scenario: a greater difference between peak and off-peak electricity tariff leads to a shorter payback period of each technology. - Highlights: • Techno-economic evaluation of energy storage solutions for cooling applications. • Comparison between five energy storage (EES, SHTES, PCM, CAES, LAES) is performed. • Qualitative and quantitative performance parameters were used for the analysis. • LAES/PCM can be valid alternatives to more established technologies EES, SHTES, CAES. • Tariffs, price arbitrage and investment cost play a key role in energy storage spread.

  14. Simultaneous Feedback Control of Plasma Rotation and Stored Energy on the DIII-D Tokamak

    International Nuclear Information System (INIS)

    Scoville, J.T.; Ferron, J.R.; Humphreys, D.A.; Walker, M.L.

    2006-01-01

    One of the major modifications made to the DIII-D tokamak during the 2005 Long Torus Opening was the rotation of one of the four two-source neutral beam injection systems. Prior to this modification, all beams injected power with a component in the same direction as the usual plasma current ('' co-injection ''). Starting in early 2006, two of the seven beams inject with a component in the opposite direction ('' counter-injection ''). This new capability allows, for the first time, a partial decoupling of the injected energy and momentum during neutral beam heating experiments. An immediate advantage of mixed co- and counter-injection beams is the capability to control the plasma rotation velocity. High beta plasmas can now be studied over a wide range of the plasma rotation velocity. The stabilizing effect of rotation on the resistive wall mode (RWM), for example, can be directly compared to the stabilization achieved by external feedback coils. This is an advantage over previous techniques to control plasma rotation, such as magnetic braking, which have had only limited success. We describe development and implementation of a model-based control algorithm for simultaneous regulation of plasma rotation and beta. The model includes the two relevant plasma states (plasma rotation and stored energy), and describes the dynamic effects of the relevant actuators on those states. The actuators include the applied beam torque and beam power, which depend on the amount of co and counter-injected beams. Implementation of the model-based control within the plasma control system (PCS) [B.G. Penaflor, et al, '' Current Status of DIII-D Plasma Control System Computer Upgrades,'' Fusion Eng. and Design 71 (2004) 47] requires real-time measurements of the plasma rotation, obtained from the charge exchange recombination (CER) diagnostic, and stored energy calculated by the real-time EFIT equilibrium reconstruction. Details of this model and its development, and a comparison with

  15. Thermoluminescence of strontium tetraborate

    International Nuclear Information System (INIS)

    Santiago, M.; Caselli, E.; Lester, M.

    1999-01-01

    The thermoluminescent properties of crystalline strontium tetraborate are reported. Without activators it has an efficiency comparable to that of TLD-700 powder. Its fading after 40 days amount to less than 2%. The isometric plot shows that most of the emitted light is concentrated at wavelengths ranging from 350 to 450 nm, which accounts partially for the high efficiency. (author)

  16. Instrumentation in thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    Julius, H.W.

    1986-01-01

    In the performance of a thermoluminescence dosimetry (TLD) system the equipment plays an important role. Crucial parameters of instrumentation in TLD are discussed in some detail. A review is given of equipment available on the market today - with some emphasis on automation - which is partly based on information from industry and others involved in research and development. (author)

  17. High-voltage many-pulses generator with inductive energy store and fuse

    International Nuclear Information System (INIS)

    Kovalev, V.P.; Diyankov, V.S.; Kormilitsin, A.I.; Lavrent'ev, B.N.

    1996-01-01

    The high-voltage generator with inductive energy store and fuses as opening switch that generate series of powerful pulses is considered. This generator differs from the ordinary generator with inductive store by the cross-section of the series copper wires. The parameters of the wires are chosen based on empirical relations. The generation principle was tested on the two high-voltage generators with characteristic impedance 2.2 ohm, 4 ohm and with output voltages of 140 kV and 420 kV, respectively. Copper wires 0.1 to 0.23 mm in diameter were used. Series of 2 to 5 pulses of 100 to 300 ns duration, 400 to 1000 kV amplitude and 1 - 10 GW power were obtained. Pulses can be both the same and different. Two successive bremsstrahlung radiation pulses were obtain on the EMIR-M and IGUR-3 devices. Series power megavolt pulses can be generated with a power exceeding 10 11 W, pulse duration of 10 -3 to 10 -6 s, and time interval between them 10 -7 to 10 -5 s. (author). 4 figs., 2 refs

  18. High-voltage many-pulses generator with inductive energy store and fuse

    Energy Technology Data Exchange (ETDEWEB)

    Kovalev, V P; Diyankov, V S; Kormilitsin, A I; Lavrent` ev, B N [All-Russian Research Inst. of Technical Physics, Snezhinsk (Russian Federation)

    1997-12-31

    The high-voltage generator with inductive energy store and fuses as opening switch that generate series of powerful pulses is considered. This generator differs from the ordinary generator with inductive store by the cross-section of the series copper wires. The parameters of the wires are chosen based on empirical relations. The generation principle was tested on the two high-voltage generators with characteristic impedance 2.2 ohm, 4 ohm and with output voltages of 140 kV and 420 kV, respectively. Copper wires 0.1 to 0.23 mm in diameter were used. Series of 2 to 5 pulses of 100 to 300 ns duration, 400 to 1000 kV amplitude and 1 - 10 GW power were obtained. Pulses can be both the same and different. Two successive bremsstrahlung radiation pulses were obtain on the EMIR-M and IGUR-3 devices. Series power megavolt pulses can be generated with a power exceeding 10{sup 11} W, pulse duration of 10{sup -3} to 10{sup -6} s, and time interval between them 10{sup -7} to 10{sup -5} s. (author). 4 figs., 2 refs.

  19. Changes in energy metabolism accompanying pitting in blueberries stored at low temperature.

    Science.gov (United States)

    Zhou, Qian; Zhang, Chunlei; Cheng, Shunchang; Wei, Baodong; Liu, Xiuying; Ji, Shujuan

    2014-12-01

    Low-temperature storage and transport of blueberries is widely practiced in commercial blueberry production. In this research, the storage life of blueberries was extended at low temperature, but fruit stored for 30 d at 0°C pitted after 2d at room-temperature. Fruit cellular structure and physiological parameters accompanying pitting in blueberries were changed. The objective of this research was to characterise properties of energy metabolism accompanying pitting in blueberries during storage, including adenosine phosphates and mitochondrial enzymes involved in stress responses. Physiological and metabolic disorders, changes in cell ultrastructure, energy content and ATPase enzyme activity were observed in pitting blueberries. Energy shortages and increased activity of phenylalanine ammonia lyase (PAL) and lipoxygenase (LOX) were observed in fruit kept at shelf life. The results suggested that sufficient available energy status and a stable enzymatic system in blueberries collectively contribute to improve chilling tolerance, thereby alleviating pitting and maintaining quality of blueberry fruit in long-term cold storage. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Fast liberation of energy stored using superconductors; Liberation rapide d'energie stockee au moyen de supraconducteurs

    Energy Technology Data Exchange (ETDEWEB)

    Prost, G; Sole, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    After a rapid description of the circumstances in which they first thought of using superconducting materials for the storage and liberation of energy, the authors examine, in comparison to condensers, the energy densities which can thus be stored, the methods used for introducing this energy into the superconducting circuit and for trapping it, and the law governing the discharge of this energy into a purely dissipative impedance. This leads to a derivation of the expression for the energy yield which depends on the characteristics of the switch used for opening the superconducting circuit. An experimental study has been made of a superconducting switch with a view to understanding the various parameters. As a result of this analysis, transitions of this switch, over the whole of its mass, were obtained for periods of a few microseconds, and energy yields close to unity were obtained. The obtention of fast discharges is now no longer a technological problem. (authors) [French] Rappelant tres brievement les circonstances dans lesquelles ont pris naissance leurs premieres idees d'utilisation des materiaux supraconducteurs pour le stockage et la liberation d'energie les auteurs examinent, par rapport aux condensateurs, les densites d'energie que l'on peut ainsi stocker, les methodes utilisables pour introduire cette energie dans le circuit supraconducteur et pour la pieger, la loi de decharge de cette energie dans une impedance purement dissipative. Ceci conduit a l'expression du rendement en energie. Ce rendement depend des caracteristiques de l'interrupteur qui sert a ouvrir le circuit supraconducteur. Le cas de l'interrupteur supraconducteur a ete analyse experimentalement de facon a en degager les differents parametres. La suite de cette analyse, des transitions de l'interrupteur, dans la totalite de sa masse, ont ete obtenues dans des temps de quelques microsecondes permettant des rendements en energie se rapprochant de l'unite. L'obtention de decharges rapides

  1. Plastic incompatibility stresses and stored elastic energy in plastically deformed copper

    Energy Technology Data Exchange (ETDEWEB)

    Baczmanski, A. [Faculty of Physics and Applied Computer Science, AGH-University of Science and Technology, al. Mickiewicza 30, 30-059 Krakow (Poland)], E-mail: baczman@ftj.agh.edu.pl; Hfaiedh, N.; Francois, M. [LASMIS, Universite de Technologie de Troyes, 11 rue Marie Curie, B.P. 2060, 10010 Troyes (France); Wierzbanowski, K. [Faculty of Physics and Applied Computer Science, AGH-University of Science and Technology, al. Mickiewicza 30, 30-059 Krakow (Poland)

    2009-02-15

    The X-ray diffraction method and theoretical model of elastoplastic deformation were used to examine the residual stresses in polycrystalline copper. To this end, the {l_brace}2 2 0{r_brace} strain pole figures were determined for samples subjected to different magnitudes of tensile deformation. Using diffraction data and the self-consistent model, the tensor of plastic incompatibility stress was found for each orientation of a polycrystalline grain. Crystallographic textures, macroscopic and second-order residual stresses were considered in the analysis. As a result, the distributions of elastic stored energy and von Mises equivalent stress were presented in Euler space and correlated with the preferred orientations of grains. Moreover, using the model prediction, the variation of the critical resolved shear stress with grain orientation was determined.

  2. Is there a limitation to the stored beam energy for 2011 and beyond?

    CERN Document Server

    Schmidt, R

    2011-01-01

    The machine protection systems have been designed to ultimately operate with beams of a stored energy of 360MJ. This presentation will address if there is an intermediate limit and what upgrades are required to permit operation with 360MJ. A failure in one of the protection systems (BLM, BIC, LBDS, ...) could have catastrophic consequences for LHC. Considering the operational experience, the most critical failure modes are reviewed, their probability is estimated and methods for mitigation are discussed. Ideas for reducing the risk include additional interlocks (DIDT interlock, abort gap cleaning/monitoring, fast BLMs, additional BPMs as HW interlock, aperture measurements,...), operational procedures and upgrades of hardware systems. There are also examples when the beams should NOT be dumped immediately.

  3. Utilization of stored elastic energy in leg extensor muscles by men and women.

    Science.gov (United States)

    Komi, P V; Bosco, C

    1978-01-01

    An alternating cycle of eccentric-concentric contractions in locomotion represents a sequence when storage and utilization of elastic energy takes place. It is possible that this storage capacity and its utilization depends on the imposed stretch loads in activated muscles, and that sex differences may be present in these phenomena. To investigate these assumed differences, subjects from both sexes and of good physical condition performed vertical jumps on the force-platform from the following experimental conditions: squatting jump (SJ) from a static starting position; counter-movement jump (CMJ) from a free standing position and with a preparatory counter-movement; drop jumps (DJ) from the various heights (20 to 100 cm) on to the platform followed immediately by a vertical jump. In all subjects the SJ, in which condition no appreciable storage of elastic energy takes place, produced the lowest height of rise of the whole body center of gravity (C.G.). The stretch load (drop height) influenced the performance so that height of rise of C. of G. increased when the drop height increased from 26 up to 62 cm (males) and from 20 to 50 cm (females). In all jumping conditions the men jumped higher than the women. However, examination of the utilization of elastic energy indicated that in CMJ the female subjects were able to utilize most (congruent to 90%) of the energy produced in the prestretching phase. Similarly, in DJ the overall change in positive energy over SJ condition was higher in women as compared to men. Thus the results suggest that although the leg extensor muscles of the men subjects could sustain much higher stretch loads, the females may be able to utilize a greater portion of the stored elastic energy in jumping activities.

  4. Thermoluminescent kinetic parameters of the perovskite, KMgF3, activated with lanthanum

    International Nuclear Information System (INIS)

    Sepulveda M, F.; Azorin N, J.; Rivera M, T.; Furetta, C.; Sanipoli, C.

    2004-01-01

    The thermoluminescent curves induced by the beta radiation in the perovskite KMgF 3 were investigated activated with lanthanum. The classic methods were used to determine the kinetic parameters (the kinetic order b, the activation energy E and the frequency of escape intent s) associated with the peaks of the thermoluminescent curve (Tl) in the KMgF 3 activated with lanthanum after the irradiation with beta rays. The method is based on the position of the thermoluminescent peaks, obtained of the temperature change of the peak in the maximum emission caused by the change in the heating rapidity to which the samples were measured. In this work, the samples in form of pellets were re cooked previously at 400 C during one hour before irradiating them with beta particles. The Tl measures were made with a Tl reader system using three different heating rapidities and storing the glow curves. To calculate the depth of the E traps and the frequency factor s, the parameters of the glow curve were determined experimentally of the shame of the glow curve by means of the mensuration of the shame of the maximum temperature of the peak, T M like a function of the heating rapidity. The results indicate that the values of the kinetic parameters are very near among if when they are obtained indistinctly of anyone of the different methods. (Author)

  5. A pocket type thermoluminescent personnel dosimeter

    International Nuclear Information System (INIS)

    Vora, K.G.; Nagpal, J.S.; Pendurkar, H.K.; Gangadharan, P.

    1979-01-01

    A pocket type thermoluminescent personnel dosemeter using CaSO 4 : Dy phosphor is described. Two glass capillaries containing the phosphor are fitted into a plastic tube and covered by a cylindrical filter. The combination is fitted into an ink barrel of a fountain pen. The response of this Dy glass dosimeter was studied for various incident photon energies. A uniform response over the energy range from 33 keV to 1250 keV is achieved. (A.K.)

  6. Phosphor for thermoluminescent type radiation dosimeter

    International Nuclear Information System (INIS)

    Nada, N.; Yamashita, T.

    1975-01-01

    This has the accumulation effect of radiation energy and is mainly used as the element for thermoluminescent type radiation dosimeters. It has as the principal constituent a phosphor consisting of calcium sulfate as the principal constituent and other impurity elements such as dysprosium, thulium and the like. It is more sensitive by the order of 1 to 2 or more figures than the conventional ones and is excellent in the retention of absorbed radiation energy. (U.S.)

  7. Thermoluminescent dosimetry: theory, materials and applications

    International Nuclear Information System (INIS)

    Rosa, L.A.R.da.

    1978-01-01

    A survey about the thermoluminescence theory, the properties of the main thermoluminescent phosphors and their applications is presented. Some of the most important thermoluminescent readers are also mentioned [pt

  8. Regulation of Energy Stores and Feeding by Neuronal and Peripheral CREB Activity in Drosophila

    Science.gov (United States)

    Iijima, Koichi; Zhao, LiJuan; Shenton, Christopher; Iijima-Ando, Kanae

    2009-01-01

    The cAMP-responsive transcription factor CREB functions in adipose tissue and liver to regulate glycogen and lipid metabolism in mammals. While Drosophila has a homolog of mammalian CREB, dCREB2, its role in energy metabolism is not fully understood. Using tissue-specific expression of a dominant-negative form of CREB (DN-CREB), we have examined the effect of blocking CREB activity in neurons and in the fat body, the primary energy storage depot with functions of adipose tissue and the liver in flies, on energy balance, stress resistance and feeding behavior. We found that disruption of CREB function in neurons reduced glycogen and lipid stores and increased sensitivity to starvation. Expression of DN-CREB in the fat body also reduced glycogen levels, while it did not affect starvation sensitivity, presumably due to increased lipid levels in these flies. Interestingly, blocking CREB activity in the fat body increased food intake. These flies did not show a significant change in overall body size, suggesting that disruption of CREB activity in the fat body caused an obese-like phenotype. Using a transgenic CRE-luciferase reporter, we further demonstrated that disruption of the adipokinetic hormone receptor, which is functionally related to mammalian glucagon and β-adrenergic signaling, in the fat body reduced CRE-mediated transcription in flies. This study demonstrates that CREB activity in either neuronal or peripheral tissues regulates energy balance in Drosophila, and that the key signaling pathway regulating CREB activity in peripheral tissue is evolutionarily conserved. PMID:20041126

  9. Thermoluminescence studies in geology

    International Nuclear Information System (INIS)

    Sankaran, A.V.; Sunta, C.M.; Nambi, K.S.V.; Bapat, V.N.

    1980-01-01

    Even though the phenomenon of thermoluminescence is well studied, particularly over last 3 decades, its potentialities in the field of geology have not been adequately evaluated. In this report several useful applications of TL in mineralogy, petrogenesis, stratigraphy, tectonics, ore-prospecting and other branches have been identified with particular emphasis to the Indian scene. Important areas in the country that may provide the basic material for such studies are indicated at the end along with brief geological or mineralogical accounts. (auth.)

  10. Thermoluminescence spectra of amethyst

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Q. [Suzhou Railway Teachers College (China). Dept. of Physics; Yang, B. [Beijing Normal University (China). Dept. of Physics; Wood, R.A.; White, D.R.R.; Townsend, P.D.; Luff, B.J. [Sussex Univ., Brighton (United Kingdom). School of Mathematical and Physical Sciences

    1994-04-01

    Thermoluminescence and cathodoluminescence data from natural and synthetic amethyst and synthetic quartz samples are compared. The spectra include features from the quartz host lattice and from impurity-generated recombination sites. Emission features exist throughout the wavelength range studied, 250-800 nm. The near infrared emission at 740-750 nm appears to be characteristic of the amethyst and is proposed to be due to Fe ion impurity. (Author).

  11. SU-G-201-08: Energy Response of Thermoluminescent Microcube Dosimeters in Water for Kilovoltage X-Ray Beams

    Energy Technology Data Exchange (ETDEWEB)

    Di Maso, L; Lawless, M; Culberson, W; DeWerd, L [University of Wisconsin- Madison, Madison, WI (United States)

    2016-06-15

    Purpose: To characterize the energy dependence for TLD-100 microcubes in water at kilovoltage energies. Methods: TLD-100 microcubes with dimensions of (1 × 1 × 1) mm{sup 3} were irradiated with kilovoltage x-rays in a custom-built thin-window liquid water phantom. The TLD-100 microcubes were held in Virtual Water™ probes and aligned at a 2 cm depth in water. Irradiations were performed using the M-series x-ray beams of energies ranging from 50-250 kVp and normalized to a {sup 60}Co beam located at the UWADCL. Simulations using the EGSnrc Monte Carlo Code System were performed to model the x-ray beams, the {sup 60}Co beam, the water phantom and the dosimeters in the phantom. The egs-chamber user code was used to tally the dose to the TLDs and the dose to water. The measurements and calculations were used to determine the intrinsic energy dependence, absorbed-dose energy dependence, and absorbed-dose sensitivity. These values were compared to TLD-100 chips with dimensions of (3.2 × 0.9 × 0.9) mm{sup 3}. Results: The measured TLD-100 microcube response per dose to water among all investigated x-ray energies had a maximum percent difference of 61% relative to {sup 60}Co. The simulated ratio of dose to water to the dose to TLD had a maximum percent difference of 29% relative to {sup 60}Co. The ratio of dose to TLD to the TLD output had a maximum percent difference of 13% relative to {sup 60}Co. The maximum percent difference for the absorbed-dose sensitivity was 15% more than the used value of 1.41. Conclusion: These results confirm that differences in beam quality have a significant effect on TLD response when irradiated in water. These results also indicated a difference in TLD-100 response between microcube and chip geometries. The intrinsic energy dependence and the absorbed-dose energy dependence deviated up to 10% between TLD-100 microcubes and chips.

  12. Adipose energy stores, physical work, and the metabolic syndrome: lessons from hummingbirds

    Directory of Open Access Journals (Sweden)

    Hargrove James L

    2005-12-01

    Full Text Available Abstract Hummingbirds and other nectar-feeding, migratory birds possess unusual adaptive traits that offer important lessons concerning obesity, diabetes and the metabolic syndrome. Hummingbirds consume a high sugar diet and have fasting glucose levels that would be severely hyperglycemic in humans, yet these nectar-fed birds recover most glucose that is filtered into the urine. Hummingbirds accumulate over 40% body fat shortly before migrations in the spring and autumn. Despite hyperglycemia and seasonally elevated body fat, the birds are not known to become diabetic in the sense of developing polyuria (glucosuria, polydipsia and polyphagia. The tiny (3–4 g Ruby-throated hummingbird has among the highest mass-specific metabolic rates known, and loses most of its stored fat in 20 h by flying up to 600 miles across the Gulf of Mexico. During the breeding season, it becomes lean and maintains an extremely accurate energy balance. In addition, hummingbirds can quickly enter torpor and reduce resting metabolic rates by 10-fold. Thus, hummingbirds are wonderful examples of the adaptive nature of fat tissue, and may offer lessons concerning prevention of metabolic syndrome in humans.

  13. Effects of Material Properties on the Total Stored Energy of a Hybrid Flywheel Rotor

    Energy Technology Data Exchange (ETDEWEB)

    Ha, S.K.; Yoon, Y.B. [Hanyang University, Seoul (Korea); Han, S.C. [Korea Electric Power Research Institute, Taejon (Korea)

    2000-05-01

    A numerical method based on an assumption of a generalized plane strain (GPS) state is presented for calculating the stress and strength ratio distributions of the rotating composite flywheel rotor of varying material properties in the radial direction. The rotor is divided into many rings and each ring has constant material properties. All the rings are assumed to expand and have the same axial strain. A three-dimensional finite element method is then used to verify the accuracy of the present method for various height ratios and ply angles. This method gives a better solution for most of the rotors than other methods of a plane stress or plane strain state. After verification, the effects of material properties on the total stored energy (TSE) of the composite flywheel rotor are investigated. For this purpose, the material properties of the rotor, i.e., circumferential and radial Youngs moduli, ply angles and mass densities, are expressed by power functions of the radius and the rotor is analyzed. The analysis shows that TSE can be most effectively increased by changing the circumferential Youngs moduli along the radius, which amounts to over 300% of TSE of the constant material properties. The variation of ply angles along the radius can increase TSE by about 30% at most. The method of changing the mass densities along the radius could be also effective but its effects are not so noticeable in the rotor where the circumferential stiffness is properly arranged. (author). 24 refs., 7 figs.

  14. Adipose energy stores, physical work, and the metabolic syndrome: lessons from hummingbirds.

    Science.gov (United States)

    Hargrove, James L

    2005-12-13

    Hummingbirds and other nectar-feeding, migratory birds possess unusual adaptive traits that offer important lessons concerning obesity, diabetes and the metabolic syndrome. Hummingbirds consume a high sugar diet and have fasting glucose levels that would be severely hyperglycemic in humans, yet these nectar-fed birds recover most glucose that is filtered into the urine. Hummingbirds accumulate over 40% body fat shortly before migrations in the spring and autumn. Despite hyperglycemia and seasonally elevated body fat, the birds are not known to become diabetic in the sense of developing polyuria (glucosuria), polydipsia and polyphagia. The tiny (3-4 g) Ruby-throated hummingbird has among the highest mass-specific metabolic rates known, and loses most of its stored fat in 20 h by flying up to 600 miles across the Gulf of Mexico. During the breeding season, it becomes lean and maintains an extremely accurate energy balance. In addition, hummingbirds can quickly enter torpor and reduce resting metabolic rates by 10-fold. Thus, hummingbirds are wonderful examples of the adaptive nature of fat tissue, and may offer lessons concerning prevention of metabolic syndrome in humans.

  15. Thermoluminescence dosemeter for personal dose equivalent assessment

    International Nuclear Information System (INIS)

    Silva, T.A. da; Rosa, L.A.R. da; Campos, L.L.

    1995-01-01

    The possibility was investigated of utilising a Brazilian thermoluminescence individual dosemeter, usually calibrated in terms of photon dose equivalent, for the assessment of the personal dose equivalent, H p (d), at depths of 0.07 and 10 mm. The dosemeter uses four CaSO 4 :Dy thermoluminescent detectors, between different filters, as the sensitive materials. It was calibrated in gamma and X radiation fields in the energy range from 17 to 1250 keV. Linear combinations of the responses of three detectors, in this energy range, allow the evaluation of H p (0.07) and H p (10), for radiation incidence angles varying from 0 to 60 degrees, with an accuracy better than 35%. The method is not applicable to mixed photon-beta fields. (author)

  16. Spectral Modeling of Residual Stress and Stored Elastic Strain Energy in Thermal Barrier Coatings

    Energy Technology Data Exchange (ETDEWEB)

    Donegan, Sean; Rolett, Anthony

    2013-12-31

    Solutions to the thermoelastic problem are important for characterizing the response under temperature change of refractory systems. This work extends a spectral fast Fourier transform (FFT) technique to analyze the thermoelastic behavior of thermal barrier coatings (TBCs), with the intent of probing the local origins of failure in TBCs. The thermoelastic FFT (teFFT) approach allows for the characterization of local thermal residual stress and strain fields, which constitute the origins of failure in TBC systems. A technique based on statistical extreme value theory known as peaks-over-threshold (POT) is developed to quantify the extreme values ("hot spots") of stored elastic strain energy (i.e., elastic energy density, or EED). The resolution dependence of the teFFT method is assessed through a sensitivity study of the extreme values in EED. The sensitivity study is performed both for the local (point-by-point) eld distributions as well as the grain scale eld distributions. A convergence behavior to a particular distribution shape is demonstrated for the local elds. The grain scale fields are shown to exhibit a possible convergence to a maximum level of EED. To apply the teFFT method to TBC systems, 3D synthetic microstructures are created to approximate actual TBC microstructures. The morphology of the grains in each constituent layer as well as the texture is controlled. A variety of TBC materials, including industry standard materials and potential future materials, are analyzed using the teFFT. The resulting hot spots are quantified using the POT approach. A correlation between hot spots in EED and interface rumpling between constituent layers is demonstrated, particularly for the interface between the bond coat (BC) and the thermally grown oxide (TGO) layer.

  17. Invited paper: distributed energy store railgun system experimental results and analysis

    International Nuclear Information System (INIS)

    Holland, L.D.

    1983-01-01

    The Center for Electromechanics (CEM-UT) has constructed a distributed energy store railgun facility. The facility contains a 33-in. railgun with four current feed connection points and a 142-in. railgun with connections for all ten of the capacitor bank modules with pulse forming inductors that are used to power the railguns. Each of the ten capacitor bank modules can supply up to 200 kA with a maximum energy of 60 kJ. Each capacitor bank is turned on as the projectile moves down the bore of the gun as detected by magnetic pickup coils. Designed to achieve velocities in excess of 10 kmats, the guns are accelerating 3/8-in. Lexan cubes weighing between 0.5 and 1.0 g. This system has been operated at over 500 kA for repeated shots from zero initial velocity or a single set of rails. A theoretical analysis of the DES railgun system has been made. This includes a two-dimensional current diffusion analysis which has resulted in a simple approximate formula for rail resistance. The theoretical model is a two-dimensional steady state solution. The current feed points to the rails move along the rails with the same velocity as the armature. This model is reasonably approximated by a DES railgun and allows the use of steady state solution techniques. The approximate formula for the rail resistance has been used to predict maximum allowable current levels per unit height of the rails. Current levels greater than 50% of the predicted limits have been tested in the railguns. A simple modeling technique for determining the driving inductance of a railgun is presented

  18. Energy expenditure in people with transtibial amputation walking with crossover and energy storing prosthetic feet: A randomized within-subject study.

    Science.gov (United States)

    McDonald, Cody L; Kramer, Patricia A; Morgan, Sara J; Halsne, Elizabeth G; Cheever, Sarah M; Hafner, Brian J

    2018-05-01

    Energy storing feet are unable to reduce the energy required for normal locomotion among people with transtibial amputation. Crossover feet, which incorporate aspects of energy storing and running specific feet, are designed to maximize energy return while providing stability for everyday activities. Do crossover prosthetic feet reduce the energy expenditure of walking across a range of speeds, when compared with energy storing feet among people with transtibial amputation due to non-dysvascular causes? A randomized within-subject study was conducted with a volunteer sample of twenty-seven adults with unilateral transtibial amputation due to non-dysvascular causes. Participants were fit with two prostheses. One had an energy storing foot (Össur Variflex) and the other a crossover foot (Össur Cheetah Xplore). Other components, including sockets, suspension, and interface were standardized. Energy expenditure was measured with a portable respirometer (Cosmed K4b2) while participants walked on a treadmill at self-selected slow, comfortable, and fast speeds with each prosthesis. Gross oxygen consumption rates (VO 2  ml/min) were compared between foot conditions. Energy storing feet were used as the baseline condition because they are used by most people with a lower limb prosthesis. Analyses were performed to identify people who may benefit from transition to crossover feet. On average, participants had lower oxygen consumption in the crossover foot condition compared to the energy storing foot condition at each self-selected walking speed, but this difference was not statistically significant. Participants with farther six-minute walk test distances, higher daily step counts, and higher Medicare Functional Classification Levels at baseline were more likely to use less energy in the crossover foot. Crossover feet may be most beneficial for people with higher activity levels and physical fitness. Further research is needed to examine the effect of crossover feet on

  19. Performance tests on the NRPB thermoluminescent dosemeter

    CERN Document Server

    Shaw, K B

    1977-01-01

    Performance tests on the thermoluminescent dosemeter, designed at NRPB for use in the automated personal dosimetry system, are described. An ultra-thin lithium borate dosemeter has been developed for skin absorbed dose measurement. The X-ray, gamma-ray and beta-ray energy response of the dosemeter has been investigated and the angular response for the dosemeter has been examined. The annealing, read-out and stabilisation procedures for the dosemeter are described.

  20. Thermoluminescence: its understanding and applications

    International Nuclear Information System (INIS)

    Nambi, K.S.V.

    1977-01-01

    The phenomenon of thermoluminescence is treated exhaustively both mathematically and physically. All the possible applications of the phenomenon are briefly described and an optimistic picture of the future trends in this field is projected. A review of latest information on thermoluminescence instrumentation and phosphors is also included [pt

  1. Thermoluminescence of films of metal oxides and its application to the low energy ionizing radiation dosimetry; Termoluminiscencia de peliculas de oxidos metalicos y su aplicacion a la dosimetria de la radiacion ionizante de baja energia

    Energy Technology Data Exchange (ETDEWEB)

    Azorin N, J.; Rivera M, T.; Furetta, C. [Departamento de Fisica, Universidad Autonoma Metropolitana-Iztapalapa, 09000 Mexico D.F. (Mexico); Falcony G, C. [Departamento de Fisica, Centro de Investigacion y Estudios Avanzados, IPN, 07000 Mexico D.F. (Mexico); Martinez S, E.; Garcia H, M. [Instituto de Investigaciones en Materiales, UNAM, 04510 Mexico D.F. (Mexico)

    2002-07-01

    The obtained results from 1997 to date in the project {sup S}tudy of the thermoluminescence of metal oxides and their application to the ionizing radiation as regards to the development of ZrO{sub 2} and of Al{sub 2}O{sub 3} doped and without doped films with rare earths are presented. The obtained results irradiating ZrO{sub 2} and of Al{sub 2}O{sub 3} films with ultraviolet light and visible light have been satisfactory; whereas these materials have resulted promising to measure beta particles, X-rays and low energy gamma rays. (Author)

  2. Thermoluminescence of pyramid stones

    International Nuclear Information System (INIS)

    Gomaa, M.A.; Eid, A.M.

    1982-01-01

    It is the aim of the present study to investigate some thermoluminescence properties of pyramid stones. Using a few grammes of pyramid stones from Pyramids I and II, the TL glow peaks were observed at 250 and 310 0 C, respectively. The TL glow peaks of samples annealed at 600 0 C, then exposed to 60 Co γ-rays were observed at 120, 190 and 310 0 C, respectively. The accumulated dose of natural samples is estimated to be around 310 Gray (31 krad). By assuming an annual dose is 1 mGy, the estimated age of pyramid stones is 0.31 M year. (author)

  3. Thermoluminescence of pyramid stones

    Energy Technology Data Exchange (ETDEWEB)

    Gomaa, M A; Eid, A M [Atomic Energy Establishment, Cairo (Egypt)

    1982-01-01

    It is the aim of the present study to investigate some thermoluminescence properties of pyramid stones. Using a few grammes of pyramid stones from Pyramids I and II, the TL glow peaks were observed at 250 and 310/sup 0/C, respectively. The TL glow peaks of samples annealed at 600/sup 0/C, then exposed to /sup 60/Co ..gamma..-rays were observed at 120, 190 and 310/sup 0/C, respectively. The accumulated dose of natural samples is estimated to be around 310 Gray (31 krad). By assuming an annual dose is 1 mGy, the estimated age of pyramid stones is 0.31 M year.

  4. The ability to store energy in pea protein gels is set by network dimensions smaller than 50 nm

    NARCIS (Netherlands)

    Munialo, C.D.; Linden, van der E.; Jongh, de H.H.J.

    2014-01-01

    The objective of this study was to identify which length scales set the ability to elastically store energy in pea protein network structures. Various network structures were obtained frompea proteins by varying the pH and salt conditions during gel formation. The coarseness of the network structure

  5. Food Store Choice Among Urban Slum Women Is Associated With Consumption of Energy-Dense Food.

    Science.gov (United States)

    Anggraini, Roselynne; Februhartanty, Judhiastuty; Bardosono, Saptawati; Khusun, Helda; Worsley, Anthony

    2016-07-01

    The aim of this study was to examine the associations of food store choice with food consumption among urban slum women. A cross-sectional survey was carried out among 188 urban slum women (19-50 years old) in Jakarta, Indonesia. A semiquantitative food frequency questionnaire was used to assess food consumption. Associations between food consumption and food store choice were tested by linear regression. This study found that frequencies of buying food from small shops (warung), street food vendors, and modern food stores were significantly associated with consumption of snacks, mixed dishes, and fruit respectively. In addition, buying food from traditional markets and small cafes (warung makan) was not significantly associated with particular types of food consumption. As modern food stores are rarely utilized by these women, small shops (warung) and street food vendors are likely to be important channels to improve slum dwellers' diet. © 2016 APJPH.

  6. Thermoluminescent behavior of diamond thin films exposed to ultraviolet radiation

    International Nuclear Information System (INIS)

    Barboza F, M.; Gastelum, S.; Melendrez, R.; Chernov, V.; Bernal, R.; Cruz V, C.; Brown, F.

    2002-01-01

    In this work the thermoluminescent properties of diamond thin films are discussed which are grown up through the chemical vapor method exposed to ultraviolet radiation of 200-280 nm. The films with thickness 3, 6, 9, 12, 180 and 500 microns were grown up using a precursor gas formed of H 2 -CH 4 -CO excited through microwave energy or hot filament.The structure and morphology of the films were examined through scanning electron microscopy, indicating the formation of different diamond polycrystal structures which depend on the type of heating of the precursor gas used as well as the film dimensions. In general, the brilliance curve depends on the sample and the wavelength of the irradiation ultraviolet light, however it presents clearly thermoluminescence bands in 148, 160, 272, 304, 320 and 324 C degrees. The maximum of the thermoluminescence efficiency is obtained for the case of sample exposure with light of 214 nm. The sample of 500 microns is what exhibits greater thermoluminescent efficiency of those studied samples. The thermoluminescent behavior in function of radiation dose presents regions of linearity and supra linearity for higher and small doses respectively. The disappearance of the thermoluminescent signal depends on the characteristics of the film and it can reach until a 30 % of loss before to reach the stability. (Author)

  7. Experimental research on the use of micro-encapsulated Phase Change Materials to store solar energy in concrete floors in order to save energy in Dutch houses

    NARCIS (Netherlands)

    Entrop, A.G.; Brouwers, H.J.H.; Reinders, A.H.M.E.

    2011-01-01

    In this paper an experimental research is presented on a new use of Phase Change Materials (PCMs) in concrete floors, in which thermal energy provided by the sun is stored in a mix of concrete and PCMs. When this thermal energy is being released – in moderate sea climates during the evening and

  8. Experimental research on the use of micro-encapsulated Phase Change Materials to store solar energy in concrete floors and to save energy in Dutch houses

    NARCIS (Netherlands)

    Entrop, Alexis Gerardus; Brouwers, Jos; Reinders, Angelina H.M.E.

    2011-01-01

    In this paper an experimental research is presented on a new use of Phase Change Materials (PCMs) in concrete floors, in which thermal energy provided by the sun is stored in a mix of concrete and PCMs. When this thermal energy is being released – in moderate sea climates during the evening and

  9. Simple methodologies to estimate the energy amount stored in a tree due to an explosive seed dispersal mechanism

    Science.gov (United States)

    do Carmo, Eduardo; Goncalves Hönnicke, Marcelo

    2018-05-01

    There are different forms to introduce/illustrate the energy concepts for the basic physics students. The explosive seed dispersal mechanism found in a variety of trees could be one of them. Sibipiruna trees carry out fruits (pods) who show such an explosive mechanism. During the explosion, the pods throw out seeds several meters away. In this manuscript we show simple methodologies to estimate the energy amount stored in the Sibipiruna tree due to such a process. Two different physics approaches were used to carry out this study: by monitoring indoor and in situ the explosive seed dispersal mechanism and by measuring the elastic constant of the pod shell. An energy of the order of kJ was found to be stored in a single tree due to such an explosive mechanism.

  10. Thermoluminescent system for low temperatures

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da; Caldas, L.V.E.; Leite, N.G.

    1988-09-01

    A system for measurements of the thermoluminescent glow curve, the thermoluminescent emission spectrum and the optical absorption spectrum of solid samples, from liquid nitrogen temperature up to 473 K, is reported. A specially designed temperature programmer provides a linear heating of the sample at a wide range of selectable heating rates, as also long term steady-state temperatures for annealing and isothermal decay studies. The system operates at a pressure of 1.33 x 10 -3 Pa. Presently it is being used for lithium fluoride low temperature thermoluminescent studies. (author) [pt

  11. The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons.

    Science.gov (United States)

    Thorpe, Chavaunne T; Godinho, Marta S C; Riley, Graham P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2015-12-01

    While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy storage and return. In the equine forelimb, the energy storing superficial digital flexor tendon (SDFT) has much higher failure strains than the positional common digital extensor tendon (CDET). However, we have previously shown that this is not due to differences in the properties of the SDFT and CDET fascicles (the largest tendon subunits). Instead, there is a greater capacity for interfascicular sliding in the SDFT which facilitates the greater extensions in this particular tendon (Thorpe et al., 2012). In the current study, we exposed fascicles and interfascicular matrix (IFM) from the SDFT and CDET to cyclic loading followed by a test to failure. The results show that IFM mechanical behaviour is not a result of irreversible deformation, but the IFM is able to withstand cyclic loading, and is more elastic in the SDFT than in the CDET. We also assessed the effect of ageing on IFM properties, demonstrating that the IFM is less able to resist repetitive loading as it ages, becoming stiffer with increasing age in the SDFT. These results provide further indications that the IFM is important for efficient function in energy storing tendons, and age-related alterations to the IFM may compromise function and predispose older tendons to injury. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Thermoluminescence of irradiated foods

    International Nuclear Information System (INIS)

    Wagner, U.; Helle, N.; Boegl, K.W.; Schreiber, G.A.

    1993-01-01

    This report describes developments and applications of the thermoluminescence (TL) analysis of mineral contaminants in foods. Procedures are presented to obtain minerals from most different products such as pepper, mangos, shrimps and mussels. The effect of light exposure during the storage of foods on the TL intensity of minerals is examined and corresponding conclusions for routine control are drawn. It is also shown that the normalization of TL intensities - the essential step to identify irradiated samples - can not only be achieved by γ, X or β rays but also by UV radiation. The results allow the conclusion that a clear identification of any food which has been irradiated with more than 1 kGy is possible if enough minerals can be isolated. (orig.)

  13. Thermo-luminescent dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Reither, M; Schorn, B; Schneider, E

    1981-01-01

    The development of paediatric radiology which began in the late 195O's has been characterised by the need to limit the dose of ionising radiation to which the child is subjected. The aim has been to keep radiation exposure as low as possible by the introduction of suitable techniques and by the development of new methods. It is therefore surprising that studies in dosimetry in the paediaytric age range have only been carried out in recent years. One reason for this may have been the fact that a suitable technique of measurement was not available at the time. The introduction of solid state dosimetry based on thermo-luminescence, first into radiotherapy (1968) and subsequently into radiodiagnosis, has made it possible to abandon the previously widely used ionisation chamber. The purpose of the present paper is to indicate the suitability of this form of dose measurement for paediatric radiological purposes and to stimulate its application in this field.

  14. THE ROLE OF FAST MAGNETOSONIC WAVES IN THE RELEASE AND CONVERSION VIA RECONNECTION OF ENERGY STORED BY A CURRENT SHEET

    Energy Technology Data Exchange (ETDEWEB)

    Longcope, D. W.; Tarr, L. [Department of Physics, Montana State University, Bozeman, MT 59717 (United States)

    2012-09-10

    Using a simple two-dimensional, zero-{beta} model, we explore the manner by which reconnection at a current sheet releases and dissipates free magnetic energy. We find that only a small fraction (3%-11% depending on current-sheet size) of the energy is stored close enough to the current sheet to be dissipated abruptly by the reconnection process. The remaining energy, stored in the larger-scale field, is converted to kinetic energy in a fast magnetosonic disturbance propagating away from the reconnection site, carrying the initial current and generating reconnection-associated flows (inflow and outflow). Some of this reflects from the lower boundary (the photosphere) and refracts back to the X-point reconnection site. Most of this inward wave energy is reflected back again and continues to bounce between X-point and photosphere until it is gradually dissipated, over many transits. This phase of the energy dissipation process is thus global and lasts far longer than the initial purely local phase. In the process, a significant fraction of the energy (25%-60%) remains as undissipated fast magnetosonic waves propagating away from the reconnection site, primarily upward. This flare-generated wave is initiated by unbalanced Lorentz forces in the reconnection-disrupted current sheet, rather than by dissipation-generated pressure, as some previous models have assumed. Depending on the orientation of the initial current sheet, the wave front is either a rarefaction, with backward-directed flow, or a compression, with forward-directed flow.

  15. The roles of direct input of energy from the solar wind and unloading of stored magnetotail energy in driving magnetospheric substorms

    Science.gov (United States)

    Rostoker, G.; Akasofu, S. I.; Baumjohann, W.; Kamide, Y.; Mcpherron, R. L.

    1987-01-01

    The contributions to the substorm expansive phase of direct energy input from the solar wind and from energy stored in the magnetotail which is released in an unpredictable manner are considered. Two physical processes for the dispensation of the energy input from the solar wind are identified: (1) a driven process in which energy supplied from the solar wind is directly dissipated in the ionosphere; and (2) a loading-unloading process in which energy from the solar wind is first stored in the magnetotail and then is suddenly released to be deposited in the ionosphere. The pattern of substorm development in response to changes in the interplanetary medium has been elucidated for a canonical isolated substorm.

  16. Investigations on thermoluminescent dosimetry (TLD) with doped alumina ceramics

    International Nuclear Information System (INIS)

    Janas, R.; Huebner, K.

    1976-01-01

    Alumina ceramics doped and burned under various conditions have been investigated with regard to their suitability for thermoluminescent dosimetry. The production of ceramics is described. The properties essential for dosimetric purposes, such as glow curve, energy dose characteristics, fading, recoverability, lower detection limit and energy dependence, are indicated. The advantages and disadvantages of alumina ceramics are compared. (author)

  17. Neutron bombardment of single wall carbon nanohorn (SWCNH). DSC determination of the stored Wigner-Szilard energy

    International Nuclear Information System (INIS)

    Franco Cataldo; Susana Iglesias-Groth; Yaser Hafez; Giancarlo Angelini

    2014-01-01

    Single wall carbon nanohorn (SWCNH) were neutron-bombarded to a dose of 3.28 × 10 16 n/cm 2 . The Wigner or stored energy was determined by a differential scanning calorimeter and was found 5.49 J/g, 50 times higher than the Wigner energy measured on graphite flakes treated at the same neutron dose. The activation energy for the thermal annealing of the accumulated radiation damage in SWCNH was determined in the range 6.3-6.6 eV against a typical activation energy for the annealing of the radiation-damaged graphite which is in the range of 1.4-1.5 eV. Furthermore the stored energy in neutron-damaged SWCNH is released at 400-430 deg C while the main peak in the neutron-damaged graphite occurs at 200-220 deg C. The radiation damaged SWCNH were examined with FT-IR spectroscopy showing the formation of acetylenic and aliphatic moieties suggesting the aromatic C=C breakdown caused by the neutron bombardment. (author)

  18. Neutron dosimetry using activation of thermoluminescent CaSO 4

    Science.gov (United States)

    Azorín, Juan; Gutiérrez, Alicia

    1984-11-01

    Sulfur activation in calcium sulfate doped with dysprosium (CaSO 4:Dy) thermoluminescent powder, which is bound in pure sulfur, has been used to measure the fast neutron dose at the tangential beam port of a Triga Mark III reactor. After a post-irradiation time of 3 d, the dosimeters were annealed at 600°C for 30 min in order to erase all the thermoluminescence acquired during the irradiation. The dosimeters were then stored to allow self-irradiation by betas from 32P produced by sulfur activation. The thermoluminescent signal accumulated during a post-irradiation time of 20 d due to a neutron fluence of 2.2 × 10 11 n/cm 2 was equivalent to an absorbed dose of 10 mGy of 60Co gamma rays. The thermoluminescence as a function of fast neutron dose fitted to a straight line on a log-log scale from 1 Gy to 10 4Gy.

  19. Obtention of a thermoluminescent material for dosimetry of ionizing radiation

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.

    1990-01-01

    The thermoluminescent dosemeters are small crystals which suffer changes in their structure by the radiation effect, being displaced the electrons toward higher energy levels. On heating the previously irradiated crystals, the electrons come back to their base state emitting light photons. The light quantity emitted is proportional to the received radiation dose. The light quantity emitted is proportional to the received radiation dose. The lithium fluoride is one of the thermoluminescent materials considered as tissue equivalents by having a low effective atomic number (Z ef ). At present, the more used commercial product used of this type is the TLD-100*. In this work the obtained results in the preparation of the lithium fluoride thermoluminescent material are presented. This is activated with magnesium (Mg) and titanium (Ti), which we have labelled as: LiF: Mg, Ti. The results from the tests performed for verifying his thermoluminescent properties are presented too, as powder form as in pellets form. These tests were performed in simultaneous form with TLD-100 samples, which is considered as reference. The LiF: Mg, Ti thermoluminescent material manufactured in the ININ presents similar dosimetric characteristics to those ones of the TLD-100. Therefore being able to replace the imported dosemeters. * (TLD-100 is a commercial trademark registered by Harshaw/Filtrol (US) for LiF: Mg, Ti Tl dosemeters) (Author)

  20. Bleaching of the thermoluminescence of feldspars by sunlight

    International Nuclear Information System (INIS)

    Robertson, G.B.; Prescott, J.R.; Hutton, J.T.

    1991-01-01

    Feldspars are an important component of materials used for thermoluminescence (TL) and photoluminescence (PL) dating of sediments; and successful dating implies a knowledge of the degree of re-setting by exposure to sunlight of the stored luminescence energy. We have studied the bleaching by full sunlight of the TL of six alkali feldspars of representative composition and of one oligoclase. The high potassium and high sodium feldspars are the brightest, and are also the least easily bleached, whereas those of intermediate (K-Na) composition bleach quickly. On a time scale of upwards of 16 h, all samples would have bleached enough for them to be useful for TL dating. A search was made for individual glow curve peaks that bleach particularly quickly (and are thus similar to the well-known 325 o C peak used in the TL dating of quartz). In the samples studied, there was only one glow curve peak that was selectively susceptible to bleaching: the 280 o C peak in oligoclase. (author)

  1. Thermoluminescence detected in Magicicada sp. exoskeletons

    International Nuclear Information System (INIS)

    Fields, D.E.; Randall, R.B.; Bauman, C.E. III

    1979-01-01

    Thermoluminescent emission from the irradiated exoskeletons of cicada have been observed. At a heating rate of approximately 60 0 C/min. the peak light emission temperature was 183 +- 3 0 C. This effect corresponds to charge-carrier trap parameters of Esub(a) = 0.82 +- 0.04 eV and w 0 = 10sup(9.1 +- 0.5) sec -1 . Response to filtered γ radiation of 50-kV peak energy was on the order of 3.2 x 10 6 photons/R/g. Insect exoskeletons are thus potentially useful as dosimeters. (author)

  2. Thermoluminescence of metal oxides and its applications to the dosimetry of low energy ionizing radiation; Termoluminiscencia de oxidos metalicos y su aplicacion a la dosimetria de la radiacion ionizante de baja energia

    Energy Technology Data Exchange (ETDEWEB)

    Azorin N, J. [CICATA-IPN, 11500 Mexico D.F. (Mexico); Rivera M, T. [Universidad Autonoma Metropolitana-Iztapalapa, 09340 Mexico D.F. (Mexico); Falcony G, C. [CINVESTAV-IPN, DEpartamento de Fisica, 07300 Mexico D.F. (Mexico); Martinez S, E.; Garcia H, M. [Universidad Nacional Autonoma de Mexico, Instituto de Investigaciones en Materiales, 04510 Mexico D.F. (Mexico)

    1999-07-01

    There are presented the results obtained since 1997 at present in the project Study of the thermoluminescence of metal oxides and its applications to the dosimetry of ionizing radiation. Its have been developed ZrO{sub 2} films without doping and doped with Eu, Tb, and Mn as well as Al{sub 2}O{sub 3} films without doping and doped with Na. The results obtained to the irradiated films of ZrO{sub 2} with ultraviolet and visible lights have been satisfactory. The Al{sub 2}O{sub 3} in film form showed to be a promising material for the measuring ultraviolet light and the pellets of ZrO{sub 2} + Ptfe for X-rays and low energy gamma rays. (Author)

  3. Radiation induced defects and thermoluminescence mechanism in aluminum oxide

    Energy Technology Data Exchange (ETDEWEB)

    Atobe, K.; Kobayashi, T.; Awata, T. [Naruto Univ. of Education, Tokushima (Japan); Okada, M. [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst; Nakagawa, M. [Kagawa Univ., Faculty of Education, Takamatsu, Kagawa (Japan)

    2001-01-01

    The thermoluminescence of the irradiated aluminum oxides were measured to study the radiation induced defects and their behaviors. Neutron and {gamma}-ray irradiation were performed for a shingle crystal of the high purity aluminum oxide. The thermoluminescence glow curve and its activation energy were measured. The spectroscopy measurement on the thermoluminescence and the absorption are also carried out. The observed 430 and 340 nm peaks are discussed relating to the F{sup +} and F centers, respectively. Activation state of the F center transits to 3P state through 1P state by emitting phonons. Trapped electron on 3P state emits phonon of 2.9 eV (430 nm) during transition to the ground state. The above reaction can be written by the equation. F{sup +} + e {yields} (F){sup *} {yields} F + h{nu}(2.9 eV, 470 nm). (Katsuta, H.)

  4. Target Pilots Energy Efficiency Measures for Broad Rollout in Existing Stores

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-03-01

    Target Corporation partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to retrofit existing buildings to reduce annual energy consumption by at least 30% versus requirements set by ASHRAE/ANSI/IESNA Standard 90.1-20041 as part of DOE’s Commercial Building Partnership (CBP) program.

  5. Development of a highly sensitive lithium fluoride thermoluminescence dosimeter

    International Nuclear Information System (INIS)

    Moraes da Silva, Teresinha de; Campos, Leticia Lucente

    1995-01-01

    In recent times, LiF: Mg, Cu, P thermoluminescent phosphor has been increasingly in use for radiation monitoring due its high sensitivity and ease of preparation. The Dosimetric Materials Production Laboratory of IPEN, (Nuclear Energy Institute) has developed a simple method to obtain high sensitivity LiF. The preparation method is described. (author). 4 refs., 1 fig., 1 tab

  6. Thermoluminescence sensitivity of ulexite after UV irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Topaksu, M., E-mail: mats@cu.edu.tr [Cukurova University, Arts-Sciences Faculty, Physics Department, 01330 Adana (Turkey); CIEMAT, Av. Complutense 22, 28040 Madrid (Spain); Correcher, V. [CIEMAT, Av. Complutense 22, 28040 Madrid (Spain); Garcia-Guinea, J. [Museo Nacional de Ciencias Naturales, (CSIC), C/José Gutiérrez Abascal 2, 28006 Madrid (Spain)

    2015-04-15

    Highlights: •UV-induced thermoluminescence emission of Turkish ulexite was studied. •There are three groups of components. •The UV exposures were performed at controlled temperatures. -- Abstract: The effects of UV radiation on the thermoluminescence (TL) properties of natural materials, in contrast to synthetic materials, have been scarcely studied. We report on the UV-induced thermoluminescence emission of a Turkish ulexite (NaCaB{sub 5}O{sub 6}(OH){sub 6}·5H{sub 2}O) that displays very complex TL glow curves, with at least three groups of components peaked at 130–140 °C, 240 °C and, 340 °C, wherein the last group is weaker. Such emission could be associated with structural changes in the lattice as well as alkali self-diffusion processes. The UV exposure performed at controlled temperatures (at room temperature (RT), 50 °C and 100 °C) produced a (i) different evolutions of the intensities of each maximum, which are directly related to the controlled thermal treatment; (ii) different intensity ratios among the groups of components; (iii) different activation energies (E{sub a}) (1.13 eV for RT, 0.99 eV for 50 °C and 0.49 eV for 100 °C) calculated using the initial rise method; and (iv) similar scattering values (12.4%, 8.2% and 12.8%), which were not a function of the controlled temperature. The thermal stability tests conducted on this borate at different temperatures, based on the T{sub stop} protocol, confirm the presence of a continuum in the distribution of the trap system with progressively increasing E{sub a} (from 0.60 to 0.90 eV)

  7. Thermoluminescence method for detection of irradiated food

    International Nuclear Information System (INIS)

    Pinnioja, S.

    1998-01-01

    A method of thermoluminescence (TL) analysis was developed for the detection of irradiated foods. The TL method is based on the determination of thermoluminescence of adhering or contaminating minerals separated from foods by wet sieving and treatment with high density liquid. Carbon tetrachloride provided a suitable alternative for foods that form gels with water. Thermoluminescence response of minerals in a first TL measurement is normalised with a second TL measurement of the same mineral sample after calibration irradiation to a dose of 5 kGy. The decision about irradiation is made on the basis of a comparison of the two TL spectra: if the two TL glow curves match in shape and intensity the sample has been irradiated, and if they are clearly different it has not been irradiated. An attractive feature of TL analysis is that the mineral material itself is used for calibration; no reference material is required. Foods of interest in the investigation were herbs, spices, berries and seafood. The presence of minerals in samples is a criterion for application of the method, and appropriate minerals were found in all herbs, spices and berries. The most common minerals in terrestrial food were tecto-silicates - quartz and feldspars - which with their intense and stable thermoluminescence were well suited for the analysis. Mica proved to be useless for detection purposes, whereas carbonate in the form of calcite separated from intestines of seafood was acceptable. Fading of the TL signal is considerable in the low temperature part of the glow curve during a storage of several months after irradiation. However, spices and herbs could easily be identified as irradiated even after two years storage. Conditions for seafood, which is stored in a freezer, are different, and only slight fading was observed after one year. The effect of mineral composition and structure on TL was studied for feldspars. Feldspars originating from subtropical and tropical regions exhibit lower TL

  8. Thermoluminescence method for detection of irradiated food

    Energy Technology Data Exchange (ETDEWEB)

    Pinnioja, S

    1998-12-31

    A method of thermoluminescence (TL) analysis was developed for the detection of irradiated foods. The TL method is based on the determination of thermoluminescence of adhering or contaminating minerals separated from foods by wet sieving and treatment with high density liquid. Carbon tetrachloride provided a suitable alternative for foods that form gels with water. Thermoluminescence response of minerals in a first TL measurement is normalised with a second TL measurement of the same mineral sample after calibration irradiation to a dose of 5 kGy. The decision about irradiation is made on the basis of a comparison of the two TL spectra: if the two TL glow curves match in shape and intensity the sample has been irradiated, and if they are clearly different it has not been irradiated. An attractive feature of TL analysis is that the mineral material itself is used for calibration; no reference material is required. Foods of interest in the investigation were herbs, spices, berries and seafood. The presence of minerals in samples is a criterion for application of the method, and appropriate minerals were found in all herbs, spices and berries. The most common minerals in terrestrial food were tecto-silicates - quartz and feldspars - which with their intense and stable thermoluminescence were well suited for the analysis. Mica proved to be useless for detection purposes, whereas carbonate in the form of calcite separated from intestines of seafood was acceptable. Fading of the TL signal is considerable in the low temperature part of the glow curve during a storage of several months after irradiation. However, spices and herbs could easily be identified as irradiated even after two years storage. Conditions for seafood, which is stored in a freezer, are different, and only slight fading was observed after one year. The effect of mineral composition and structure on TL was studied for feldspars. Feldspars originating from subtropical and tropical regions exhibit lower TL

  9. Comparative study of thermoluminescence detection methods for irradiated spices

    International Nuclear Information System (INIS)

    Kawamura, Y.; Kojima, K.; Sugita, T.; Yamada, T.; Saito, Y.

    1995-01-01

    The thermoluminescence (TL) detection methods for irradiated spices were compared using spice samples obtained on the Japanese market, irradiated at doses of 1, 5, 10 and 30 kGy and stored for 1 year before analysis. The TL intensities of irradiated spices were stable for 1 year after irradiation. Measurement with whole samples failed to identify irradiated samples. Minerals were separated from spices in sodium tungstate saturated solution and/or sodium polytungstate solution. The TL intensity of minerals which had undergone irradiation was significantly increased for all samples. However, the ranges of TL intensity of irradiated and unirradiated samples overlapped. Clear discrimination has been obtained between the TL ratios of irradiated and unirradiated spices by using normalized measurement with reirradiation. The detection limit in terms of irradiation dose is 1 kGy even in a sample that has been irradiated 1 year prior to analysis. Normalization is the best technique currently available for thermoluminescence analysis to identify irradiated spices

  10. Stored Energy Balance for Distributed PV-Based Active Generators in an AC Microgrid

    DEFF Research Database (Denmark)

    Aldana, Nelson Leonardo Diaz; Wu, Dan; Dragicevic, Tomislav

    2015-01-01

    In this paper, a decentralized strategy based on fuzzy logic is proposed for balancing the state of charge of the energy storage units for distributed PV-based active generators. The proposed method, weights the action of conventional droop control loops for privileging the charge of the energy...... expandable and can be applied to a several number of power generators interconnected in a microgrid. Frequency and voltage bus signaling is used in order to coordinate the control operation mode between units. Simulation results in a low-voltage, three-phase, islanded AC microgrid show the feasibility...... of the proposed method and its applicability even for several active generators....

  11. Environmentally Powered Yarn Arrays that Sense, Actuate, Harvest, and Store Energy (NBIT III)

    Science.gov (United States)

    2016-11-15

    other electrolytes, we surprising discovered that we can generate high electrical power output and high electrical energy per mechanical cycle without...than the gravimetric power generation capability of a cars combustion engine and (2) functioned as a torsional artificial muscle to rotate a heavy...power generation capability of a car’s combustion engine and (2) functioned as a torsional artificial muscle to rotate a heavy rotor to over 90,000

  12. Fabrication and characterization of energy storing supercapacitor devices using coconut shell based activated charcoal electrode

    International Nuclear Information System (INIS)

    Jain, Amrita; Tripathi, S.K.

    2014-01-01

    Highlights: • CST with specific surface area of 1640 m 2 g −1 was synthesized using impregnation method. • XRD studies of CST confirm the formation of graphite and amorphous C. • EDLC cell has been successfully fabricated using CST as an electrode material having good energy and power density. - Abstract: In the present studies coconut shell based treated activated charcoal (CST) was synthesized by chemical activation method using KOH (potassium hydroxide) as an activating agent. Surface area analysis shows that CST has mesopores of size 3 nm having specific surface area of 1640 m 2 g −1 . Electrochemical double layer capacitor (EDLC) was fabricated using CST as an electrode material with blend polymer electrolyte having specific capacitance of 534 mF cm −2 (equivalent to single electrode specific capacitance of 356.2 F g −1 ). The corresponding energy and power density of 88.8 Wh kg −1 and 1.63 kW kg −1 , respectively, were achieved for EDLC

  13. Fabrication and characterization of energy storing supercapacitor devices using coconut shell based activated charcoal electrode

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Amrita; Tripathi, S.K., E-mail: sktripathi16@yahoo.com

    2014-04-01

    Highlights: • CST with specific surface area of 1640 m{sup 2} g{sup −1} was synthesized using impregnation method. • XRD studies of CST confirm the formation of graphite and amorphous C. • EDLC cell has been successfully fabricated using CST as an electrode material having good energy and power density. - Abstract: In the present studies coconut shell based treated activated charcoal (CST) was synthesized by chemical activation method using KOH (potassium hydroxide) as an activating agent. Surface area analysis shows that CST has mesopores of size 3 nm having specific surface area of 1640 m{sup 2} g{sup −1}. Electrochemical double layer capacitor (EDLC) was fabricated using CST as an electrode material with blend polymer electrolyte having specific capacitance of 534 mF cm{sup −2} (equivalent to single electrode specific capacitance of 356.2 F g{sup −1}). The corresponding energy and power density of 88.8 Wh kg{sup −1} and 1.63 kW kg{sup −1}, respectively, were achieved for EDLC.

  14. The underground as a storage facility. Modelling of nuclear waste repositories and aquifer thermal energy stores

    International Nuclear Information System (INIS)

    Probert, T.

    1998-06-01

    This thesis, which consists of eleven papers and reports, deals with nuclear waste repositories in solid rock and with aquifer thermal energy storage systems. All these storage systems induce multidimensional, time-variable thermo-hydro-elastic processes in the ground in and around the storage region. The partial differential equations that govern the physical processes are solved analytically in some cases, and in other cases numerical models are developed. Many methods of classical mathematical physics are employed for the solution. The analytical approach provides a deeper physical understanding of the processes and their interactions. At large depths, the salinity of groundwater, and hence its density, often increases downwards. In the first study, the upward buoyancy flow of groundwater in fracture planes due to heat release from the nuclear waste is studied considering the added effect of a salt gradient. The aim of the study is to determine the natural barrier effect caused by the salt. A simple formula for the largest upward displacement from the repository is derived. There may be a strong natural barrier, which is independent of fracture permeabilities. In two papers, the temperature field in rock due to a large rectangular grid of heat-releasing canisters containing nuclear waste is studied. The solution is by superposition divided into different parts. There is a global temperature field due to the large rectangular canister area, while a local field accounts for the remaining heat source problem. A complete analytical solution is presented. In the next set of papers, the thermoelastic response from the rectangular field of nuclear waste is analysed. Another study concerns the use of heat as a tracer to investigate flow in a fracture plane. Two papers deal with the thermohydraulic evaluations of two aquifer thermal energy storage projects in southern Sweden. Both plants have been successfully simulated using models based on conformal flow and entropy

  15. Thermoluminescent kinetic parameters of the perovskite, KMgF{sub 3}, activated with lanthanum; Parametros cineticos termoluminiscentes de la perovskita, KMgF{sub 3}, activada con lantano

    Energy Technology Data Exchange (ETDEWEB)

    Sepulveda M, F. [ESFM-IPN, 07738 Mexico D.F. (Mexico); Azorin N, J.; Rivera M, T. [UAM-I, 09340 Mexico D.F. (Mexico); Furetta, C.; Sanipoli, C. [Physics Department, Universita di Roma ' ' La Sapienza' ' , Piazzale A. Moro 2, 00185 Roma (Italy)

    2004-07-01

    The thermoluminescent curves induced by the beta radiation in the perovskite KMgF{sub 3} were investigated activated with lanthanum. The classic methods were used to determine the kinetic parameters (the kinetic order b, the activation energy E and the frequency of escape intent s) associated with the peaks of the thermoluminescent curve (Tl) in the KMgF{sub 3} activated with lanthanum after the irradiation with beta rays. The method is based on the position of the thermoluminescent peaks, obtained of the temperature change of the peak in the maximum emission caused by the change in the heating rapidity to which the samples were measured. In this work, the samples in form of pellets were re cooked previously at 400 C during one hour before irradiating them with beta particles. The Tl measures were made with a Tl reader system using three different heating rapidities and storing the glow curves. To calculate the depth of the E traps and the frequency factor s, the parameters of the glow curve were determined experimentally of the shame of the glow curve by means of the mensuration of the shame of the maximum temperature of the peak, T{sub M} like a function of the heating rapidity. The results indicate that the values of the kinetic parameters are very near among if when they are obtained indistinctly of anyone of the different methods. (Author)

  16. Energy storage: feasibility study to collect, store and release energy from solar origin, using a kinetic battery stockage

    Energy Technology Data Exchange (ETDEWEB)

    Tatry, B

    1976-02-01

    The feasibility of using solar energy to feed an autonomous station providing electric current continuously was studied. As an energy storage device a 'superflywheel' (rotor with composite fibers - magnetic bearings) would be used. Results show that such an experiment can be reasonably envisaged only in highly sunny countries and that it becomes non profitable at our latitudes, despite the very good performance of the flywheel storage device.

  17. High stored-energy breakdown tests on electrodes made of stainless steel, copper, titanium and molybdenum

    Energy Technology Data Exchange (ETDEWEB)

    Esch, H. P. L. de, E-mail: hubert.de-esch@cea.fr; Simonin, A.; Grand, C. [CEA-Cadarache, IRFM, F-13108 St. Paul-lez-Durance (France)

    2015-04-08

    IRFM have conducted resilience tests on electrodes made of Cu, stainless steel 304L, Ti and Mo against breakdowns up to 170 kV and 300 J. The tests of the 10×10 cm{sup 2} electrodes have been performed at an electrode distance d=11 mm under vacuum (P∼5×10{sup −6} mbar). No great difference in voltage holding between the materials could be identified; all materials could reach a voltage holding between 140 and 170 kV over the 11 mm gap, i.e. results scatter within a ±10% band. After exposure to ∼10000 seconds of high-voltage (HV) on-time, having accumulated ∼1000 breakdowns, the electrodes were inspected. The anodes were covered with large and small craters. The rugosity of the anodes had increased substantially, that of the cathodes to a lesser extent. The molybdenum electrodes are least affected, but this does not show in their voltage holding capability. It is hypothesized that penetrating high-energy electrons from the breakdown project heat below the surface of the anode and cause a micro-explosion of material when melting point is exceeded. Polished electrodes have also been tested. The polishing results in a substantially reduced breakdown rate in the beginning, but after having suffered a relatively small number (∼100) of breakdowns, the polished electrodes behaved the same as the unpolished ones.

  18. The heliothermic lake: a direct method of collecting and storing solar energy

    Science.gov (United States)

    Kirkland, Douglas W.; Bradbury, J. Platt; Dean, Walter E.

    1980-01-01

    Heliothermic lakes contain a sun-heated layer of warm, saline water beneath a surface layer of cooler, less saline water. The two layers are separated by a chemocline, a stratum in which salinity increases progressively with depth. The chemocline, the position of which varies from lake to lake, functions as a heat trap. Most sunlight that penetrates this stratum is transformed into heat, which cannot escape by radiation because water is opaque to infrared light, and which cannot escape by convection because the specific gravity of the dense water below the chemocline is not significantly decreased by the increasing temperature. Heat can escape only by conduction through the chemocline, and water or brine is a very poor conductor. As a result, the temperature within and commonly below the chemocline rises. Under ideal conditions of a clear solution, high isolation, and a suitable salinity distribution, the temperature of the chemocline will increase to the boiling point. The lower part of the chemocline in a shallow (0.8-m) manmade heliothermic lake at Sedom, Israel, for example, reached a temperature of 96°C (205°F) in spite of a brine with poor light transmissibility.About 30 natural heliothermic lakes have been reported. The best known, Lake Ursului, occurs in Transylvania, Romania (latitude, 46°35'N). During four consecutive summers, 1899 to 1902, this lake had temperatures of 60-70°C (140-158°F) at a depth of 1-2 m. Heliothermic conditions have persisted in this lake for at least 28 and probably for more than 77 years. The most unusual, Lake Vanda, Victoria Land, Antarctica (latitude, 77°35'S), has a temperature of 26°C near the base of the chemocline at a depth of 61 despite a mean atmospheric temperature of -20°C. Sunlight penetrates into the chemocline through 5 m of remarkably clear ice.Maintenance of the chemocline is the chief problem preventing commercial use of manmade heliothermic lakes for the collection and storage of solar energy. The most

  19. Microcomputer-controlled thermoluminescent analyser IJS MR-200

    International Nuclear Information System (INIS)

    Mihelic, M.; Miklavzic, U.; Rupnik, Z.; Satalic, P.; Spreizer, F.; Zerovnik, I.

    1985-01-01

    Performances and concept of the multipurpose, microcomputer-controlled thermoluminescent analyser, designed for use in laboratory work TL dosemeters as well as for routine dose readings in the range from ecological to accident doses is described. The main features of the analyser are: time-linear sampling, digitalisation, storing, and subsequent displaying on the monitor time scale of the glow and and temperature curve of the TL material; digital stabilization, control and diagnostic of the analog unit; ability of storing 7 different 8-parametric heating programs; ability of storing 15 evaluation programs defined by 2 or 4 parameters and 3 different algorithms (altogether 5 types of evaluations). Analyser has several features intended for routine work: 9 function keys and possibilities of file forming on cassette or display disc, of dose calculation and averaging, of printing reports with names, and possibility of additional programming in Basic. (author)

  20. Kerma determination in air on mamma by thermoluminescence

    International Nuclear Information System (INIS)

    Palacios P, L. L.; Rivera M, T.

    2009-10-01

    In this work the experimental results of the entrance exposition are shown and Kerma in air [mGy] in mamma obtained by irradiation of accreditation phantom of American College of Radiology (ACR). The irradiations were realized in a conventional mammography equipment of Hospital Juarez in Mexico; the technique used during the irradiations was of automatic exposition; the thickness for the phantom ACR obtained by the technique were of 4.2 and 4.5 cm; the kilo voltage pick was of 24 kV p , the time and the milli amperage per second variable. The measuring of Kerma in air was obtained with thermoluminescent dosemeters of solid state, of nano particles of zirconium dioxide prepared by the precipitation method. The dosemeters were homogenized previously in low energies of X-rays that are those used for mammography. The thermoluminescent dosemeters of ZrO 2 were calibrated by means of an ionization chamber for different expositions. The calibration curve is reported for the exposition and Kerma in air against thermoluminescent intensity obtained by reading of thermoluminescent dosemeters of ZrO 2 , as well as the technique employee for the Kerma determination in air and entrance exposition in mamma. (Author)

  1. Selected references on thermoluminescent dosemeters for personnel monitoring

    International Nuclear Information System (INIS)

    Lawson, Helen

    1976-08-01

    This bibliography contains references on: specific thermoluminescent dosemeters used for personnel dosimetry; comparisons of thermoluminescent and other dosemeters for personnel monitoring and read-out apparatus for thermoluminescent dosemeters. An appendix contains selected foreign language references. (author)

  2. Healthy Zero Energy Buildings (HZEB) Program - Cross-Sectional Study of Contaminant Levels, Source, Strengths, and Ventilation Rates in Retail Stores

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Wanyu R.; Sidheswaran, Meera; Cohn, Sebastian; Sullivan, Douglas P.; Fisk, William

    2014-02-01

    This field study measured ventilation rates and indoor air quality parameters in 21 visits to retail stores in California. The data was collected to guide the development of new, science-based commercial building ventilation rate standards that balance the dual objectives of increasing energy efficiency and maintaining acceptable indoor air quality. Data collection occurred between September 2011 and March 2013. Three types of stores participated in this study: grocery stores, furniture/hardware stores, and apparel stores. Ventilation rates and indoor air contaminant concentrations were measured on a weekday, typically between 9 am and 6 pm. Ventilation rates measured using a tracer gas decay method exceeded the minimum requirement of California’s Title 24 Standard in all but one store. Even though there was adequate ventilation according to Title 24, concentrations of formaldehyde, acetaldehyde, and acrolein exceeded the most stringent chronic health guidelines. Other indoor air contaminants measured included carbon dioxide (CO{sub 2}), carbon monoxide (CO), ozone (O{sub 3}), and particulate matter (PM). Concentrations of CO{sub 2} were kept low by adequate ventilation, and were assumed low also because the sampling occurred on a weekday when retail stores were less busy. CO concentrations were also low. The indoor-outdoor ratios of O{sub 3} showed that the first-order loss rate may vary by store trade types and also by ventilation mode (mechanical versus natural). Analysis of fine and ultrafine PM measurements showed that a substantial portion of the particle mass in grocery stores with cooking-related emissions was in particles less than 0.3 μm. Stores without cooking as an indoor source had PM size distributions that were more similar indoors and outdoors. The whole-building emission rates of volatile organic compounds (VOCs) and PM were estimated from the measured ventilation rates and indoor and outdoor contaminant concentrations. Mass balance models were

  3. Thermal modelling of borehole heat exchangers and borehole thermal energy stores; Zur thermischen Modellierung von Erdwaermesonden und Erdsonden-Waermespeichern

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Dan

    2011-07-15

    The thermal use of the underground for heating and cooling applications can be done with borehole heat exchangers. This work deals with the further development of the modelling of thermal transport processes inside and outside the borehole as well as with the application of the further developed models. The combination of high accuracy and short computation time is achieved by the development of three-dimensional thermal resistance and capacity models for borehole heat exchangers. Short transient transport processes can be calculated by the developed model with a considerable higher dynamic and accuracy than with known models from literature. The model is used to evaluate measurement data of a thermal response test by parameter estimation technique with a transient three-dimensional model for the first time. Clear advantages like shortening of the test duration are shown. The developed borehole heat exchanger model is combined with a three-dimensional description of the underground in the Finite-Element-Program FEFLOW. The influence of moving groundwater on borehole heat exchangers and borehole thermal energy stores is then quantified.

  4. Dosimetry of accidents using thermoluminescence of dental restorative porcelains

    International Nuclear Information System (INIS)

    Mauricio, C.L.P.; Rosa, L.A.R. da; Cunha, P.G. da

    1986-01-01

    The thermoluminescence (TL) properties of dental restorative porcelain were investigated with the aim of using this material as a TL dosemeter to estimate high doses in radiological accidents. The irradiations were carried out with a 60 Co gamma source and X rays with effective energies from 29 to 95 KeV. The samples have a limit of detection at about 50R and their reproducibility is better than 15%. Linearity was observed from 50 to 5000R. (Author) [pt

  5. Substance for thermoluminescent dosimetry of photon radiation in adipose tissue

    International Nuclear Information System (INIS)

    Kalmykov, L.Z.; Kandel', T.G.

    1983-01-01

    Substance composition for thermoluminescent photon dosimetry in adipose tissue is proposed which makes it possible to simplify dosimetric measurements and to improve their accuracy. The substance consists of powder-like thermoluminophor Li 2 B 4 O 7 (0.03%Mn) 48-52 mass % and bistriethylammonium dodecahydrododecaborane - 48-52 mass %. The above substance is equivalent in respect to dosimetry to adipose tissue within the 10 keV - 10 MeV energy range

  6. Thermoluminescent measurement in space radiation dosimetry

    International Nuclear Information System (INIS)

    Chen Mei; Qi Zhangnian; Li Xianggao; Huang Zengxin; Jia Xianghong; Wang Genliang

    1999-01-01

    The author introduced the space radiation environment and the application of thermoluminescent measurement in space radiation dosimetry. Space ionization radiation is charged particles radiation. Space radiation dosimetry was developed for protecting astronauts against space radiation. Thermoluminescent measurement is an excellent method used in the spaceship cabin. Also the authors mentioned the recent works here

  7. Clay as Thermoluminescence Dosemeter in diagnostic Radiology ...

    African Journals Online (AJOL)

    This paper reports the investigation of the basic thermoluminescence properties of clay at x-rays in the diagnostic radiology range, including dose monitoring in abdominal radiography. Clay sourced from Calabar, Nigeria, was tested for thermoluminescence response after irradiation at diagnostic radiology doses, including ...

  8. Numerical analysis of thermoluminescence glow curves

    International Nuclear Information System (INIS)

    Gomez Ros, J. M.; Delgado, A.

    1989-01-01

    This report presents a method for the numerical analysis of complex thermoluminescence glow curves resolving the individual glow peak components. The method employs first order kinetics analytical expressions and is based In a Marquart-Levenberg minimization procedure. A simplified version of this method for thermoluminescence dosimetry (TLD) is also described and specifically developed to operate whit Lithium Fluoride TLD-100. (Author). 36 refs

  9. Thermoluminescence spectra measured with a Michelson interferometer

    International Nuclear Information System (INIS)

    Haschberger, P.

    1991-01-01

    A Michelson interferometer was redesigned to prove its capabilities in the measurement of short-lived, low-intensity thermoluminescence spectra. Interferograms are collected during heating up the thermoluminescent probe in a heater plate. A personal computer controls the data acquisition and processes the Fourier transform. As the results show, even a comparatively simple and limited setup leads to relevant and reproducible spectra. (author)

  10. Ultraviolet dosimetry using thermoluminescent phosphors - an update

    International Nuclear Information System (INIS)

    Nagpal, J.S.

    1998-04-01

    Intrinsic response of various thermoluminescent (TL) materials such as CaSO 4 (Dy, Eu, Mn, Sm, Tb, or Tm), LiF (Mg, Cu, P), Mg 2 SiO 4 :Tb, CaF 2 :Dy, CaF 2 :Tb, ThO 2 :Tb and Al 2 O 3 (Si, Ti); cathodoluminescent phosphors Y 3 Al 5 O 12 :Ce, Y 3 Al 5 O 12 :Tb and Y(V,P)O 4 :Eu; and fluorescent lamp phosphors calcium halophosphate (Mn,Sb) and Ce Mg aluminate (Eu, Tb) to ultraviolet (UV) radiations has been studied. Intrinsic TL response of most of the phosphors is rate (radiant flux) dependent. For the first time, UV response of the materials is reported for a fixed total radiant energy (total UV dose), at a single radiant flux (260 μW.cm -2 ), for an appropriate comparison. A wide range of UV sensitivity is observed. Studies conducted using UV radiation from two unfiltered low pressure mercury lamps show significant differences in glow curves, as compared to those obtained with nearly monochromatic UV radiations. Photons of wavelength 365 nm induce bleaching of TL induced by 254 nm photons, in most of the materials. Sequential/tandem exposures to 254 nm and 365 nm photons have yielded new but alarming results in CaF 2 :Tb. Preferential induction and bleaching of specific TL glow peaks by 365 nm and 254 nm photons are interesting characteristics discovered in CaSO 4 :Eu. Photoluminescence studies of Tb 3+ and Eu 3+ activated phosphors have augmented the inferences drawn from the bleaching effects produced by 365 nm photons. Earlier work carried out on phototransferred thermoluminescence of CaSO 4 :Dy-teflon dosimeters, TLD-100, Mg 2 SiO 4 :Tb and Al 2 O 3 (Si,Ti) has also been reviewed. (author)

  11. Thermoluminescence dating of pleistocene sediments

    International Nuclear Information System (INIS)

    Poupeau, G.; Souza, J.H.; Rivera, A.

    1984-01-01

    After a short introduction on recent trends in quaternary geochronology, this article focuses on the thermoluminescence dating of sediments, whose principles and present limits and prospects are discussed. Results are presented for the TL behaviour of sands from various geological contexts in Brazil. They show that the coarse (approx. 100-200μm) quartz fraction of coastal and intra continental, eolian and fluvial-type deposits, might be datable by TL from the upper Holocene to at least the basis of the upper Pleistocene, with a precision of + - 10-15%. (Author) [pt

  12. Thermoluminescence dating of pleistocene sediments

    International Nuclear Information System (INIS)

    Poupeau, G.; Souza, J.H.

    1984-01-01

    After a short introduction on recent trends in quaternary geochronology, this article focuses on the thermoluminescence (TL) dating of sediments, whose principles, present limits and prospects are discussed. Results are presented for TL behavior of sands from various geological contexts in Brazil. They show that the coarse (approx. 100-200 μm) quartz fraction of coastal and intracontinental, eolian and fluvial - type deposits, might be datable by TL from the upper Holocene to at least the base of the upper Pleistocene, with a precision of +- 10-15%. (Author) [pt

  13. Thermoluminescence study of lithium fluorides

    CERN Document Server

    Abu-Alazm, S M

    2003-01-01

    The spectrum of the light emitted during thermoluminescence (TL) from irradiated lif sample with different doses of Xe, Kr and electrons have been studied. The results show a main peak for all samples irradiated and unirradiated at temperature about 200 degree C. Morcever when the reaches to the value 5x10 sup 1 1 ion/cm sup 2 a new two bands begin to appear in case of Xe and Kr ion irradiation. The TL spectra under Kr and Xe ion irradiation similar at the same dose. However, the spectra under electron irradiation were found to be rather different than under heavy ions irradiation.

  14. Models and methods in thermoluminescence

    International Nuclear Information System (INIS)

    Furetta, C.

    2005-01-01

    This work contains a conference that was treated about the principles of the luminescence phenomena, the mathematical treatment concerning the thermoluminescent emission of light as well as the Randall-Wilkins model, the Garlick-Gibson model, the Adirovitch model, the May-Partridge model, the Braunlich-Scharman model, the mixed first and second order kinetics, the methods for evaluating the kinetics parameters such as the initial rise method, the various heating rates method, the isothermal decay method and those methods based on the analysis of the glow curve shape. (Author)

  15. Models and methods in thermoluminescence

    Energy Technology Data Exchange (ETDEWEB)

    Furetta, C. [ICN, UNAM, A.P. 70-543, Mexico D.F. (Mexico)

    2005-07-01

    This work contains a conference that was treated about the principles of the luminescence phenomena, the mathematical treatment concerning the thermoluminescent emission of light as well as the Randall-Wilkins model, the Garlick-Gibson model, the Adirovitch model, the May-Partridge model, the Braunlich-Scharman model, the mixed first and second order kinetics, the methods for evaluating the kinetics parameters such as the initial rise method, the various heating rates method, the isothermal decay method and those methods based on the analysis of the glow curve shape. (Author)

  16. Evaluation of the relative thermoluminescence efficiency of LiF:Mg,Ti and LiF:Mg,Cu,P TL detectors to low-energy heavy ions

    DEFF Research Database (Denmark)

    Gieszczyk, W.; Bilski, P.; Olko, P.

    2013-01-01

    and xenon ion beams, at energies ranging from 5.0 to 9.3 MeV/n. Supra- and sublinear response was found, for the MTS-N and MCP-N, respectively, similarly as observed for γ-rays. However, the level of nonlinearity of response of studied detectors is strongly reduced by increasing values of the ion ionization...... density (no supralinearity for Xe ions, for MTS-N, within calculated uncertainties). The growth of high-temperature TL peaks, with increasing ionization density, was observed for MCP-N, what was not previously reported. At the whole range of applied energies higher efficiencies were noted for MTS......-N, for all ion species. A decrease of the efficiency with decrease of the ion energy was confirmed, for both types of studied detectors. At a given energy, higher efficiency was observed for lighter ions, because of the lower ionization density. Significantly higher decrease of the efficiency was measured...

  17. Energy consumption of storing special flower bulbs. Allium, Muscari, Zantedeschia and Fritillaria; Energieverbruik bij het bewaren van bijzondere bolgewassen. Allium, Muscari, Zantedeschia en Fritillaria

    Energy Technology Data Exchange (ETDEWEB)

    Wildschut, J. [Praktijkonderzoek Plant en Omgeving PPO, Bloembollen, Boomkwekerij en Fruit, Lisse (Netherlands); Vasen, R. [DLV Plant, Wageningen (Netherlands)

    2010-03-15

    The energy use of drying and storing special flower bulbs has been mapped. From the variation in energy use between various businesses, more energy efficient ventilation, circulation and temperature standards can be derived. This way the costs for energy use in a business and at sector level can be reduced significantly [Dutch] Het energieverbruik voor drogen en bewaren van bijzondere bolgewassen is in kaart gebracht. Uit de variatie in het energieverbruik tussen de verschillende bedrijven kunnen energiezuiniger ventilatie-, circulatie- en temperatuursnormen worden afgeleid. Hiermee kunnen de kosten voor energieverbruik op het bedrijf en op sectorniveau fors verlaagd worden.

  18. Method for detecting radiation dose utilizing thermoluminescent material

    International Nuclear Information System (INIS)

    Miller, S.D.; McDonald, J.C.; Eichner, F.N.; Durham, J.S.

    1992-01-01

    The amount of ionizing radiation to which a thermoluminescent material has been exposed is determined by first cooling the thermoluminescent material and then optically stimulating the thermoluminescent material by exposure to light. Visible light emitted by the thermoluminescent material as it is allowed to warm up to room temperature is detected and counted. The thermoluminescent material may be annealed by exposure to ultraviolet light. 5 figs

  19. Thermoluminescent characteristics of CaSO{sub 4}:Dy+PTFE irradiated with high energy electron beams; Caracteristicas termoluminiscentes del CaSO{sub 4}:Dy+PTFE irradiado con haces de electrones de alta energia

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez, R.; Rivera, T.; Calderon, J. A.; Jimenez, Y. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Rodriguez, J. [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06726 Mexico D. F. (Mexico); Oviedo, O. [Centro Medico ABC, Sur 136 No. 116, Col. Las Americas, 01120 Mexico D. F. (Mexico); Azorin, J., E-mail: chagua@hotmail.com [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco 186, 09340 Mexico D. F. (Mexico)

    2011-10-15

    In the present work thermoluminescent response of dysprosium doped calcium sulfate embedded in polytetrafluorethylene (CaSO{sub 4}:Dy+PTFE) under high electron beam irradiations from linear accelerator for clinical applications was investigated. The irradiations were carried out using high electron beams (6 to 18 MeV) from a linear accelerator Varian, C linac 2300C/D, for clinical practice purpose. The electron irradiations were obtained by using the water solid in order to guarantee electronic equilibrium conditions. Field shaping for electron beams was obtained with electron cones. Glow curve and other thermoluminescent characteristics of CaSO{sub 4}:Dy+PTFE were conducted under high electron beams irradiations. The thermoluminescent response of the pellets showed and intensity peak centered at around 235 C. Thermoluminescent response of CaSO{sub 4}:Dy+PTFE as a function of high electron absorbed dose showed a linearity in a wide range. To obtain reproducibility characteristic, a set of pellets were exposed repeatedly for the same electron absorbed dose. The results obtained in this study can suggest the applicability of CaSO{sub 4}:Dy+PTFE pellets for high electron beam dosimetry, provided fading is correctly accounted for. (Author)

  20. Accumulated energy determination in salts rocks irradiated by means of thermoluminescence techniques: application to the high level radioactive wastes repositories analysis

    International Nuclear Information System (INIS)

    Dies, J.; Ortega. J.; Tarrasa. F.; Cuevas, C.

    1995-01-01

    The report summarizes the study carried out to develop the radiation effects on salt rocks in order to repository the high level radioactive wastes. The study is structured into 3 main aspects: 1.- Analysis of irradiation experiences in Haw project of Pet ten reactor. 2.- Irradiation of salt sample of CESAR industrial irradiator. 3.- Correlation study between the accumulated energy, termoluminescence answer and the defect concentration

  1. Calibration procedure for thermoluminescent dosemeters in water absorbed doses for Iridium-192 high dose rate sources

    International Nuclear Information System (INIS)

    Reyes Cac, Franky Eduardo

    2004-10-01

    Thermoluminescent dosimeters are used in brachytherapy services quality assurance programs, with the aim of guaranteeing the correct radiation dose supplied to cancer patients, as well as with the purpose of evaluating new clinical procedures. This work describes a methodology for thermoluminescent dosimeters calibration in terms of absorbed dose to water for 192 Ir high dose rate sources. The reference dose used is measured with an ionization chamber previously calibrated for 192 Ir energy quality, applying the methodology proposed by Toelli. This methodology aims to standardizing the procedure, in a similar form to that used for external radiotherapy. The work evolves the adaptation of the TRS-277 Code of the International Atomic Energy Agency, for small and big cavities, through the introduction for non-uniform experimental factor, for the absorbed dose in the neighborhood of small brachytherapy sources. In order to simulate a water medium around the source during the experimental work, an acrylic phantom was used. It guarantees the reproducibility of the ionization chamber and the thermoluminescent dosimeter's location in relation to the radiation source. The values obtained with the ionization chamber and the thermoluminescent dosimeters, exposed to a 192 Ir high dose rate source, were compared and correction factors for different source-detector distances were determined for the thermoluminescent dosimeters. A numeric function was generated relating the correction factors and the source-detector distance. These correction factors are in fact the thermoluminescent dosimeter calibration factors for the 192 Ir source considered. As a possible application of this calibration methodology for thermoluminescent dosimeters, a practical range of source-detector distances is proposed for quality control of 192 Ir high dose rate sources. (author)

  2. Thermoluminescent Signals Caused by Disturbing Effects

    International Nuclear Information System (INIS)

    German, U.; Weinstein, M.; Ben-Shachar, B.

    1999-01-01

    One of the major sources of uncertainty in the measurement of low radiation doses by means of thermoluminescence dosemeters is the presence of disturbing thermoluminescence signals, especially luminescence caused by visible light, and by materials attached to the heated areas. Glow curves of thermoluminescence dosemeters contain useful information that can improve the accuracy and the reliability of the thermoluminescent measurements. The influence of the various disturbing effects can be recognised in the shape of the glow curves and can sometimes be separated from the exposure. Some examples are presented of signals arising from the two disturbing effects mentioned above, the signal contributed by Teflon used in the TLD-100 cards of Bicron/Harshaw and some abnormal glow curves due to dirt attached to the cards. Subtraction of the contributions due to these effects is suggested to obtain the net exposure signal. (author)

  3. Dose-rate dependence of thermoluminescence response

    International Nuclear Information System (INIS)

    McKeever, S.W.S.; Chen, R.; Groom, P.J.; Durrani, S.A.

    1980-01-01

    The previously observed dose-rate effect of thermoluminescence in quartz at high dose-rates is given at theoretical formulation. Computer calculations simulating the experimental conditions yield similar results to the experimental ones. (orig.)

  4. Recent advances in thermoluminescence and photostimulated luminescence detection methods for irradiated foods

    International Nuclear Information System (INIS)

    Sanderson, D.C.W.; Carmichael, L.A.; Naylor, J.D.

    1996-01-01

    Thermoluminescence (TL) and photostimulated luminescence (PSL) are radiation-specific phenomena resulting from energy storage by trapped charge carriers in dielectric materials following irradiation. Releasing such stored energy by thermal or optical stimulation can result in detectable luminescence emission during the relaxation processes which follow. These approaches can be applied to inorganic components present either as inherent parts of foods or as adhering contaminants, and to bio-inorganic systems. The strengths of these techniques lies in their radiation-specificity, and the wide range of sample types which may by analysed. The Scottish Universities Research and Reactor Centre (SURRC) has been involved in the development and application of luminescence methods since 1986, during which time over 4000 analyses of more than 800 different food samples have been performed for research purposes, or in support of UK food labelling regulations. This paper discusses the present scope of luminescence techniques, and identifies areas where recent work has extended the range of applications, and indicates areas where further investigations may be worthwhile. (author)

  5. Personnel monitoring of radiations with thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Miano, S.C.

    1987-01-01

    The basics of personnel dosimetry technics, used by the Radiologic Protetion and Assessorie Service (SAPRA) are presented, consisting on use of thermoluminescent and CaSO 4 :Dy monitors in aggregated pellets by Teflon. The characteristics of this dosemeters, relating to the sensitivity, energetic dependence, spike temperature, characteristic emission curve, decay and light effect are shown. The thermoluminescent dosemeter measure system and the personnel monitoring system are also described. (C.G.C.) [pt

  6. Personal radiation monitoring with thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Miano, S.C.

    1987-01-01

    The technique of personal dosimetry used by SAPRA (Servico de Assessoria e Protecao Radiologica S/C Ltda., Brazil) is presented. Thermoluminescent monitors and CaSO 4 : Dy are used in pastilles united by teflon. Characteristics of the dosemeters are briefly reported. The system of thermoluminescent measurement, designed and constructed by SAPRA, and the system of personal monitoring are described. (M.A.C.) [pt

  7. Thermoluminescence of LaAlO3

    International Nuclear Information System (INIS)

    Morales H, A.; Zarate M, J.; Rivera M, T.; Azorin N, J.

    2015-10-01

    In this paper the thermoluminescent properties of doped lanthanum aluminate (LaAlO 3 ) with dysprosium ion (Dy) were studied. The thermoluminescence characteristics in the samples were obtained using an ultraviolet radiation of 220 nm. The LaAlO 3 :Dy samples were prepared by the modified Pechini method (Spray Dryer). The structural and morphological characterization was obtained by X-ray diffraction (XRD) and scanning electron microscopy (Sem) techniques respectively. The size particle composing the agglomerate was determined by Sem, agglomerated particles composed size of 2μm were observed. The thermoluminescence response of LaAlO 3 :Dy was compared with that obtained with the undoped sample. Thermoluminescence brightness curves of LaAlO 3 :Dy showed a peak centered at 185 grades C. Sensitivity of doped sample was greater, about 100 times compared with the undoped sample. Thermoluminescence response in function of the wavelength showed a maximum at 220 nm. Also the fading in thermoluminescence response was studied. (Author)

  8. Who is behind the stocking of energy-dense foods and beverages in small stores? The importance of food and beverage distributors.

    Science.gov (United States)

    Ayala, Guadalupe X; D'Angelo, Heather; Gittelsohn, Joel; Horton, Lucy; Ribisl, Kurt; Sindberg, Lesley Schmidt; Olson, Christina; Kharmats, Anna; Laska, Melissa N

    2017-12-01

    The present study examined food and beverage distributors' sourcing, placement and promotion of obesogenic (energy-dense, nutrient-poor) product categories from the perspective of small food store owners/managers. The obesogenic product categories of interest were savoury snacks, sugary beverages, sweet snacks, confectionery and frozen treats. Specifically, we examined how frequently distributors sourced these products, and the types of agreements and expectations they had for their placement and promotion. Differences were explored by store size and ethnicity. Fresh produce was used as a comparison when examining differences in frequency of sourcing only, with implications for healthy food access. Survey research involving in-person interviews. Four urban areas in the USA: Baltimore, MD; Durham, NC; Minneapolis/St. Paul, MN; and San Diego, CA. Seventy-two small food store owners/managers, 65 % consent rate. Most distributors sourced obesogenic products weekly. Agreements to place products were predominantly informal (e.g. handshake) with sweet snack, confectionery and frozen treat distributors, and formal (e.g. contract) with savoury snack and sugary beverage distributors. Free-standing displays were the most common incentive provided by distributors and they expected some control over their placement and pricing. Free/discounted products and signage were also common incentives but slotting fees were not. Smaller stores and ethnic stores were less likely to receive various incentives, but among sweet snack distributors, they were more likely to control the price in ethnic v. non-ethnic stores. Obesogenic products are ubiquitous. Influencing what is made available to consumers in the retail food environment needs to consider the distributor.

  9. Differential calorimeter and temperature controller for stored energy measurements in irradiated alkali halides; Calorimetro diferencial y controlador de temperatura para medidas de energia almacenada en haluros alcalinos irradiados

    Energy Technology Data Exchange (ETDEWEB)

    Delgado Martinez, L

    1977-07-01

    The design and performance of a simple temperature-controlled differential calorimeter are presented. This system allows to measure radiation-induced stored energy in insulators, above room temperature with a differential thermal analysis method. With platelets of KC1 single crystals, the base lines obtained for T{sub 2} T{sub 1} (with T{sub 2}: irradiated sample temperature and T{sub 1}: reference sample temperature) show a smooth drift less of 0,2 degree centigree in the interval from 25 to 400 degree centigree. The discrepancy between two consecutive base lines is less than {+-} 0,02 degree centigree which implies a calorimeter sensitivity of about {+-}0,004 cal/g. This sensitivity allows to measure stored energy release in samples with a color center concentration low enough to be directly measured with a spectrophotometer so that a search for correlations among the features of the stored energy spectrum and the color center annealing can be made. (Author) 13 refs.

  10. Thermoluminescence properties of AlN ceramics

    DEFF Research Database (Denmark)

    Trinkler, L.; Christensen, P.; Agersnap Larsen, N.

    1998-01-01

    The paper describes thermoluminescence (TL) properties of AlN:Y2O3 ceramics irradiated with ionising radiation. A high TL sensitivity of AlN:Y2O3 ceramics to radiation encouraged a study of the AlN ceramics for application as a dosimetric material. The paper presents experimental data on: glow...... curve, emission spectrum, dose response, energy dependence, influence of heating rate and fading rate. The measured TL characteristics were compared with those of well-known, widely used TLDs, i.e. LiF:Mg,Ti, LiF:Mg,Cu,P and Al2O3:C. It is concluded that AlN:Y2O3 ceramics showing a radiation sensitivity...... which is approximately 50 times greater than that of LiF:Mg,Ti is an interesting dosimetry material; however due to a high fading rate of the TL of AlN:Y2O3 on storage at room temperature, a further development of the material for improving the fading characteristics is needed for its application...

  11. The NRPB automated thermoluminescent dosemeter and dose record keeping system

    International Nuclear Information System (INIS)

    Dennis, J.A.; Marshall, T.O.; Shaw, K.B.

    1975-03-01

    This report describes the thermoluminescent personal radiation dosemeter and its associated automated processing equipment, which are being developed by the National Radiological Protection Board, together with the operation of a computerised dosemeter issue and record keeping system. The main justifications for introducing these systems are improvements in the organizational efficiency of the maintenance of individual dose records, a more flexible and accurate dosimetry system, and economics in operational costs. The dosemeter is based on a numbered aluminium plate containing two lithium fluoride in polytetrafluorethylene disks for the measurement of surface and body dose. This dosemeter is wrapped in thin plastic and labelled with the wearer's name and address. On return, the dosemeter is checked automatically for radioactive contamination; it is unwrapped and evaluated; the dose readings are included in the wearer's stored dose record; the dosemeter is annealed and is then available for re-issue to another wearer. Dose reports and warnings are automatically issued to the wearer or his employer. (author)

  12. Comparison of thermoluminescence detection methods for irradiated spices

    International Nuclear Information System (INIS)

    Kawamura, Y.; Murayama, M.; Uchiyama, S.; Saito, Y.

    1996-01-01

    Thermoluminescence (TL) analysis has been shown to be one of the most applicable methods for the detection of γ-irradiated spices. This analysis was introduced as a detection technique for irradiated spices using the whole sample. It was then found that the origin of the TL response to be mineral dust adhering to the spices. TL measurements on separated minerals and the normalised TL measurement by re-irradiation was then established. This paper details investigations on TL measurements carried out using clean powdered spices stored for one year after being irradiated with doses of 1, 5, 10 and 30 kGy in order to clarify their applicable dose range, the effect of storage and mineral content. The effect of the mineral separation was also studied. (author)

  13. Auto-regenerative thermoluminescence dating using zircon inclusions

    International Nuclear Information System (INIS)

    Templer, R.H.

    1993-01-01

    Fired ceramics containing zircon inclusions have been dated by allowing the zircons to regenerate their own thermoluminescence (TL) signal, hence auto-regenerative TL dating. The technique is conceptually straightforward. One first measures the TL accrued since the last heating of the material. The zircon grains are then stored for six months and the TL signal regenerated through self-irradiation is measured. Since the internal dose-rate for zircon is dominated by the internal component the age of the sample is simply given by the ratio of the natural to auto-regenerated signal times the laboratory storage period. The technique, however, requires the measurement of a very small auto-regenerated signal, which introduces a number of experimental and physical complications. The methods for overcoming these problems and successfully dating zircons by auto-regeneration are described. (Author)

  14. Recent advances in thermoluminescence dating

    International Nuclear Information System (INIS)

    Aitken, M.J.

    1984-01-01

    Initially the application of thermoluminescent dating was to ancient pottery and other baked clay, the detection of forgeries in art ceramics having a particularly powerful impact. In recent years there has been a growing extension of TL into non-pottery materials. Heated flints from paleolithic fire-places is one application. Another is in the dating of igneous rocks from recent volcanic events; formerly this had been impossible on account of the malign phenomenon of non-thermal ('anomalous') fading exhibited by volcanic minerals but this is now being circumvented by utilising TL in the 600 0 C region of the glow curve. TL dating has also been extended to unburnt calcite, one application being stalagmitic floors in paleolithic caves. Another recent development is the use of TL for dating aeolian sediment and some types of waterborne sediment. These developments give prospect of establishing a TL-based chronology, both for archaeology and quaternary research, extending back well beyond the range of radiocarbon, perhaps reaching a million years ago. (author)

  15. Energy stored in BeO, MgO, Al2O3 and SiO2 oxides irradiated with neutrons

    International Nuclear Information System (INIS)

    Roux, Andre

    1969-01-01

    Within the field of researches on refractory oxides which may be used in structure materials in atomic pile, the objective of this research thesis has been the measurement of the energy stored in some specific oxides (BeO, MgO, Al 2 O 3 and SiO 2 ) after their irradiation in a nuclear reactor. This measurement is performed by 'healing' the irradiated substance by means of thermal treatments during which sample initial mass and morphologies are preserved. The measurement of the Wigner energy is then performed by differential enthalpy analysis. The first part reports the experimental determination of Wigner energies (measurement apparatus, method of ballistic differential enthalpy analysis, thermo-gram compensation). The second part presents the Wigner energies obtained for the sintered BeO, the sintered MgO, the sintered Al 2 O 3 , and the vitreous SiO 2 . The third part reports the result interpretation

  16. Conserving Coherence and Storing Energy during Internal Conversion: Photoinduced Dynamics of cis- and trans-Azobenzene Radical Cations

    KAUST Repository

    Munkerup, Kristin; Romanov, Dmitri A.; Bohinski, Timothy; Stephansen, Anne B.; Levis, Robert J.; Sø lling, Theis Ivan

    2017-01-01

    Light harvesting via energy storage in azobenzene has been a key topic for decades, and the process of energy distribution over the molecular degrees of freedom following photoexcitation remains to be understood. Dynamics of a photoexcited system

  17. On the second kinetic order thermoluminescent glow curves

    International Nuclear Information System (INIS)

    Dang Thanh Luong; Nguyen Hao Quang; Hoang Minh Giang

    1995-01-01

    The kinetic parameters of thermoluminescent material such as CaF 2 -N and CaSO 4 -Dy with the different grain sizes are investigated in detail using the least square method of fitting. It was found that the activation energy E (or trap depth) and peak temperature T m ax are changed with the elapsed time between the irradiation and read-out for the low temperature glow curve peaks. The similar TL glow curve shapes are obtained for the different CaSO 4 -Dy grain size. (author). 7 refs., 5 figs., 2 tabs

  18. Thermoluminescence of Stoichiometric Magnesium-Aluminium Spinel Defects

    International Nuclear Information System (INIS)

    Kobyakov, V.A.; Gritsina, V.T.; Kazarinov, Yu.G.; Volokitin, V.N.

    2005-01-01

    The investigations of thermoluminescence of spinel single crystals MgAl 2 O 4 after UV- and X-ray irradiation was provided by using method of self consisting heating. It was shown, that observed maxima at temperatures of ∼360 and ∼530 K in UV- and green ranges of spectra, respectively, are complex and consist of several strongly overlapping partial maxima. By using method of self consisting heating we have revealed the approximate position of partial maxima, which are included in maxima of ∼360 and ∼530 K, and for some partial maxima there was obtained the order of kinetics, activation energies, and frequency factors

  19. Thermoluminescence in KBr:D electron irradiated at room temperature

    International Nuclear Information System (INIS)

    Paredes Campoy, J.C.; Lopez Carranza, E.

    1991-07-01

    The thermoluminescence of KBr:D samples electron irradiated at room temperature after thermal annealing at 673 K for 1 hour have been studied in the temperature range 360-730 K. The experimental TL-curve was discomposed by computer analysis in seven overlapping TL peaks, giving for them the order of the kinetics of thermal stimulation, the activation energy, the frequency factor, the relative values of the electronic concentration in traps at the initial heating temperature and the temperature at the maximum of the peak. (author). 18 refs, 1 fig., 3 tabs

  20. Thermoluminescence properties of Eu-doped and Eu/Dy-codoped Sr2 Al2 SiO7 phosphors.

    Science.gov (United States)

    Jadhaw, Akhilesh; Sonwane, Vivek D; Gour, Anubha S; Jha, Piyush

    2017-11-01

    We report the thermoluminescence properties of Sr 1.96 Al 2 SiO 7 :Eu 0.04 and Sr 1.92 Al 2 SiO 7 :Eu 0.04 Dy 0.04 phosphors. These phosphors were prepared by a high-temperature solid-state reaction method. The prepared phosphors were characterized by X-ray diffraction. A 254 nm source was used for ultraviolet (UV) irradiation and a 60 Co source was used for γ-irradiation. The effect of heating rate and UV-exposure were examined. The thermoluminescence temperature shifts to higher values with increasing heating rate and thermoluminescence intensity increases with increasing UV exposure time. The trapping parameters such as activation energy (E), order of kinetics and frequency factor (s) were calculated by peak shape method. The effect of γ- and UV-irradiation on thermoluminescence studies was also examined. Copyright © 2017 John Wiley & Sons, Ltd.

  1. Characteristic of 120 degree C thermoluminescence peak of iceland spar

    International Nuclear Information System (INIS)

    Lu Xinwei; Han Jia

    2006-01-01

    The basic characteristic of 120 degree C thermoluminescence peak of iceland spar was studied. The experimental result indicates the longevity of 120 degree C thermoluminescence peak of iceland spar is about 2 h under 30 degree C. The thermoluminescence peak moves to the high temperature when the heating speed increasing. The intensity of 120 degree C thermoluminescence peak of iceland spar is directly proportional to radiation dose under 15 Gy. (authors)

  2. Energy dependence of thermoluminescent response of CaSO{sub 4}:Dy, LiF:Mg and micro LiF:Mg,Ti in clinical beams of electrons by using different simulator objects; Dependencia energetica da resposta TL de dosimetros de CaSO{sub 4}:Dy, LiF:Mg e microLiF:Mg,Ti em feixes clinicos de eletrons utilizando diferentes objetos simuladores

    Energy Technology Data Exchange (ETDEWEB)

    Bravim, Amanda; Campos, Leticia Lucente, E-mail: abravin@ipen.b, E-mail: rsakuraba@einstein.b, E-mail: lcrodri@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Sakuraba, Roberto K.; Cruz, Jose Carlos da, E-mail: rsakuraba@einstein.b, E-mail: josecarlosc@einstein.b [Hospital Israelita Albert Einstein (HIAE), Sao Paulo, SP (Brazil)

    2011-10-26

    Yet not so widely applied in radiotherapy, the calcium sulfate doped with dysprosium (CaSO{sub 4}:Dy) is used in radioprotection and studies has been demonstrated its great potential for the dosimetry in radiotherapy. This work evaluates the energy dependence of the thermoluminescent answer of the CaSO{sub 4}:D, LiF:Mg,Ti (TLD-100) and micro LiF:Mg,Ti in clinical beams of electrons by using water simulators, PMMA and solid water

  3. Thermoluminescent dosimetry of new phosphors of Zn O exposed to beta radiation

    International Nuclear Information System (INIS)

    Cruz V, C.; Burruel I, S.E.; Grijalva M, H.; Barboza F, M.; Bernal, R.

    2004-01-01

    In this work, we report the thermoluminescence dosimetry of a new Zn O phosphor obtained by annealing of Zn S powder precipitated when Zn S films were grown by employing a CBD method. The collected Zn S powder was pressed in a die to form pellets which were subjected to different thermal treatments under air atmosphere. X-ray diffraction (XRD) patterns and energy-dispersive X-ray Spectrometry (EDS) analyses confirmed the transformation of Zn S to Zn O. The phosphors thus obtained were exposed to high doses of beta radiation and their thermoluminescent dosimetry show that these new phosphors are materials suitable to be used in high dose thermoluminescence dosimetry. (Author)

  4. Dating of pre hispanic ceramics from the archaeological zone of Zoque by thermoluminescence method

    International Nuclear Information System (INIS)

    Valdes, J.V.; Gonzalez, P.R.; Mendoza, D.; Tenorio, D.; Terreros, E.; Ramirez, A.

    2007-01-01

    Full text: The dating of pre hispanic ceramics resides permitting us to located them in a certain period of the history; allows us to verify it origin. The thermoluminescence is a technique that permits us to estimate the absolute age of the archaeological samples. The present work is directed in determining the age by the method of thermoluminescence of archaeological samples of the grotto of Concubac, located in the Serrana Region of Tabasco. To determine the mineralogical composition of the samples, analysis of diffraction of X rays and Energy Dispersive X-ray Spectroscopy (EDS) have been conducted. The radiation emitted by the ground where the samples were buried and the contribution of the cosmic radiation was measured with thermoluminescent dosimeters of LiF:Mg,Cu,P+PTFE. The feasibility of dating of the studied samples is broadly disputed in function of the contents of minerals, as well as the procedure and management of the sample. (Author)

  5. Synthesis and thermoluminescence properties of CaF2:Tm,Ce nanoparticles

    Directory of Open Access Journals (Sweden)

    M Zahedifar

    2013-10-01

    Full Text Available Calcium fluoride nanoparticles doped with thulium and cerium were synthesized as a novel nanostructure by using the hydrothermal method. The prepared samples were characterized by X-ray diffraction (XRD and energy dispersive spectrometer (EDS. The crystallite size of about 36 nm was estimated employing Scherer’s formula. Its shape and size were also observed by scanning electron microscope (SEM. Computerized glow curve deconvolution (CGCD technique revealed two overlapping thermoluminescence glow peaks at around 402 and 457 K in the complex thermoluminescence glow curve of this phosphor. Other thermoluminescence characteristics of this phosphor such as fading, reuseability and dose response recommend it as a good candidate for high dose dosimetry.

  6. An intercomparison of the thermoluminescent efficiency of various preparations of lithium fluoride

    CERN Document Server

    Driscoll, C M H

    1977-01-01

    Possible alternative sources of supply of lithium fluoride to that used at present in the NRPB automated TLD system dosemeter are being considered on the grounds of economy and quality control. Initial measurements on the thermoluminescent properties and efficiency of various preparations of lithium fluoride are described, including the Harshaw TLD-700 which is currently in use in the automated thermoluminescent dosemeter. Material obtained from British Nuclear Fuels Ltd (which may be an atypical batch) showed 75% of the sensitivity of the Harshaw material, with around 20% fading of the signal after 1 month's storage. French material, obtained from Desmarquest and Carbonisation Entreprise et Ceramique and used by the Commissariat a l'Energie Atomique, showed good fading resistance but, after standard preparational treatments, was only half as sensitive in the thermoluminescent response. Without additional treatments to improve the characteristics of these materials, they cannot be considered as being satisfac...

  7. Acceptance Testing of Thermoluminescent Dosimeter Holders.

    Science.gov (United States)

    Romanyukha, Alexander; Grypp, Matthew D; Sharp, Thad J; DiRito, John N; Nelson, Martin E; Mavrogianis, Stanley T; Torres, Jeancarlo; Benevides, Luis A

    2018-05-01

    The U.S. Navy uses the Harshaw 8840/8841 dosimetric (DT-702/PD) system, which employs LiF:Mg,Cu,P thermoluminescent dosimeters (TLDs), developed and produced by Thermo Fisher Scientific (TFS). The dosimeter consists of four LiF:Mg,Cu,P elements, mounted in Teflon® on an aluminum card and placed in a plastic holder. The holder contains a unique filter for each chip made of copper, acrylonitrile butadiene styrene (ABS), Mylar®, and tin. For accredited dosimetry labs, the ISO/IEC 17025:2005(E) requires an acceptance procedure for all new equipment. The Naval Dosimetry Center (NDC) has developed and tested a new non-destructive procedure, which enables the verification and the evaluation of embedded filters in the holders. Testing is based on attenuation measurements of low-energy radiation transmitted through each filter in a representative sample group of holders to verify that the correct filter type and thickness are present. The measured response ratios are then compared with the expected response ratios. In addition, each element's measured response is compared to the mean response of the group. The test was designed and tested to identify significant nonconformities, such as missing copper or tin filters, double copper or double tin filters, or other nonconformities that may impact TLD response ratios. During the implementation of the developed procedure, testing revealed a holder with a double copper filter. To complete the evaluation, the impact of the nonconformities on proficiency testing was examined. The evaluation revealed failures in proficiency testing categories III and IV when these dosimeters were irradiated to high-energy betas.

  8. Concept of electric power output control system for atomic power generation plant utilizing cool energy of stored snow

    International Nuclear Information System (INIS)

    Kamimura, Seiji; Toita, Takayuki

    2003-01-01

    A concept of the SEAGUL system (Snow Enhancing Atomic-power Generation UtiLity) is proposed in this paper. Lowering the temperature of sea water for cooling of atomic-power plant will make a efficiency of power generation better and bring several ten MW additional electric power for 1356 MW class plant. The system concept stands an idea to use huge amount of seasonal storage snow for cooling water temperature control. In a case study for the Kashiwazaki-Kariwa Nuclear Power Station, it is estimated to cool down the sea water of 29degC to 20degC by 80 kt snow for 3 hours in a day would brought 60 MWh electric power per a day. Annually 38.4 Mt of stored snow will bring 1800 MWh electric power. (author)

  9. Dental tissue as a thermoluminescence dosimetry dosimeter

    International Nuclear Information System (INIS)

    Solaimani, F.; Zahmatkesh, M.H.; Akhlaghpoor, Sh.

    2003-01-01

    Background: Thermoluminescence dosimetry is one of the dosimetry procedures used widely as routine and personal dosimeters. In order to extend this kind of dosimeters, dental tissue has been examined and was found promising as a Thermoluminescence Dosimetry dosimeter. Materials and Methods: In this study, 70 health teeth were collected. The only criterion, wich was considered for selection of the teeth, was the healthiness of them regardless of age and gender of the donors. All collected samples were washed and cleaned and milled uniformly. The final powder had a uniform grain size between 100-300 micrometer. The sample was divided into four groups. Group A and B were used for measurement of density and investigation of variation of thermoluminescent characteristics with temperature respectively. Groups C and D were used for investigation of variation of thermoluminescent intensity with dose and fading of this intensity with time. In all cases the results obtained with dental tissue were compared to a standard LiF, thermoluminescence dosimetry dosimeter. Results: It was found that, average density of the dental tissue was 1.570 g/cm 3 , which is comparable to density of LiF, which is 1.612g/cm 3 . It was also concluded that the range of 0-300 d ig C , dental tissue has a simple curve with two specific peaks at 140 and 25 d ig C respectively. The experiment also showed that, the variation of relative intensity versus dose is linear in the range of 0.04-0.1 Gy. The fading rate of dental tissue is higher than LiF but still in the acceptable range (14% per month in compare to 5.2% per month). Conclusion: Dental tissue as a natural dosimeter is comparable with Thermoluminescence Dosimetry and can be used in accidental events with a good approximation

  10. Development of thermoluminescence dating techniques at Oxford

    International Nuclear Information System (INIS)

    Fleming, S.J.

    1977-01-01

    The two-decade long history of thermoluminescene as a pottery dating method is surveyed with particular reference to the various problems that have been encountered in the Oxford Laboratory's research programme. Effects, such as supralinearity and radon emanation, are explained in terms of how they are measured and how their existence influences thermoluminescence (TL) dating accuracy (currently close to plus minus 7% per analysis). Illustrations of Thermoluminescence (TL) applications include a Nok culture terracotta from Nigeria and a Cambodia bronze Buddha figure of the Khmer period, dated ising the ceramic-like casting-core retained within it. (author)

  11. Thermoluminescence: Potential Applications in Forensic Science

    Science.gov (United States)

    Ingham, J. D.; Lawson, D. D.

    1973-01-01

    In crime laboratories one of the most difficult operations is to determine unequivocally whether or not two samples of evidence of the same type were originally part of the same thing or were from the same source. It has been found that high temperature thermoluminescence (room temperature to 723 K) can be used for comparisons of this type, although work to date indicates that there is generally a finite probability for coincidental matching of glass or soil samples. Further work is required to determine and attempt to minimize these probabilities for different types of materials, and to define more clearly the scope of applicability of thermoluminescence to actual forensic situations.

  12. Annual radiation dose in thermoluminescence dating

    International Nuclear Information System (INIS)

    Li Huhou

    1988-01-01

    The annual radiation dose in thermoluminescence dating has been discussed. The autor gives an entirely new concept of the enviromental radiation in the thermoluminescence dating. Methods of annual dose detemination used by author are dating. Methods of annual dose determination used by author are summed up, and the results of different methods are compared. The emanium escapiug of three radioactive decay serieses in nature has been considered, and several determination methods are described. The contribution of cosmic rays for the annual radiation dose has been mentioned

  13. Annual radiation dose in thermoluminescence dating

    Energy Technology Data Exchange (ETDEWEB)

    Huhou, Li [Chinese Academy of Social Sciences, Beijing, BJ (China). Inst. of Archaeology

    1988-11-01

    The annual radiation dose in thermoluminescence dating has been discussed. The autor gives an entirely new concept of the enviromental radiation in the thermoluminescence dating. Methods of annual dose detemination used by author are dating. Methods of annual dose determination used by author are summed up, and the results of different methods are compared. The emanium escapiug of three radioactive decay serieses in nature has been considered, and several determination methods are described. The contribution of cosmic rays for the annual radiation dose has been mentioned.

  14. Conserving Coherence and Storing Energy during Internal Conversion: Photoinduced Dynamics of cis- and trans-Azobenzene Radical Cations

    KAUST Repository

    Munkerup, Kristin

    2017-10-24

    Light harvesting via energy storage in azobenzene has been a key topic for decades, and the process of energy distribution over the molecular degrees of freedom following photoexcitation remains to be understood. Dynamics of a photoexcited system can exhibit high degrees of non-ergodicity when it is driven by just a few degrees of freedom. Typically, an internal conversion leads to the loss of such localization of dynamics, as the intramolecular energy becomes statistically redistributed over all molecular degrees of freedom. Here, we present a unique case where the excitation energy remains localized even subsequent to internal conversion. Strong-field ionization is used to prepare cis- and trans-azobenzene radical cations on the D1 surface with little excess energy, at the equilibrium neutral geometry. These D1 ions are preferably formed because in this case D1 and D0 switch place in the presence of the strong laser field. The post-ionization dynamics is dictated by the potential energy landscape. The D1 surface is steep downhill along the cis/trans isomerization coordinate and towards a common minimum shared by the two isomers in the region of D1/D0 conical intersection. Coherent cis/trans torsional motion along this coordinate is manifested in the ion transients by a cosine modulation. In this scenario, D0 becomes populated with molecules that are energized mainly along the cis-trans isomerization coordinate, with the kinetic energy above the cis-trans inter-conversion barrier. These activated azobenzene molecules easily cycle back and forth along the D0 surface, and give rise to several periods of modulated signal before coherence is lost. This persistent localization of the internal energy during internal conversion is provided by the steep downhill potential energy surface, small initial internal energy content, and a strong hole-lone pair interaction that drives the molecule along the cis-trans isomerization coordinate to facilitate the transition between

  15. Study of a new dosimetric radio-thermoluminescent systems

    International Nuclear Information System (INIS)

    Cazac, T.C.

    1980-01-01

    This is the first Romanian study to investigate conditions to obtain the radio-thermo-luminescent systems: MgB 4 O 7 :A(A-Nd,Sm,Eu,Dy,Tb,Dy+Sm and Tb+Sm) MgF 2 A (A=Mn,Dy,Tb,Sm,Li), their essential dosimetric characters, as well as the (MgF 2 =Mn) thermophosphorus mixture with a ( 6 LiF) lithium target. An investigation was developed upon a new category of radio-thermoluminescent detectors with low radiation energy dependence and fading, magnesjum boride activated by several elements of the lanthanides class (Nd,Sm,Eu,Dy,Tb). A new radio-thermoluminescent dosimetric system with high sensitivity and moderate dependence on energy radiation - (Mnsup(2+)) manganese activated magnesium fluoride - was also studied. The author explored application of investigated detectors MgF 2 =Mn, MgB 4 O 7 =Dy and MgB 4 O 7 :Tb in neutron dosimetry in complex gamma-neutron fields. It is deemed that by using the dosimetric systems reported in the thesis in order to measure gamma, beta and neutron radiation doses, dosimetric control can be ensured both in professional dosimetry and in nuclear accident dosimetry, as well as in various basic and applicative investigations. A modest contribution is thus made towards achieving the national nuclear program through an extension of the thermophosphorus range with practical applications in nuclear radiation dosimetry. (author)

  16. Use of near infrared correlation spectroscopy for quantitation of surface iron, absorbed water and stored electronic energy in a suite of Mars soil analog materials

    Science.gov (United States)

    Coyne, Lelia M.; Banin, Amos; Carle, Glenn; Orenberg, James; Scattergood, Thomas

    1989-01-01

    A number of questions concerning the surface mineralogy and the history of water on Mars remain unresolved using the Viking analyses and Earth-based telescopic data. Identification and quantitation of iron-bearing clays on Mars would elucidate these outstanding issues. Near infrared correlation analysis, a method typically applied to qualitative and quantitative analysis of individual constituents of multicomponent mixtures, is adapted here to selection of distinctive features of a small, highly homologous series of Fe/Ca-exchanged montmorillonites and several kalinites. Independently determined measures of surface iron, relative humidity and stored electronic energy were used as constituent data for linear regression of the constituent vs. reflectance data throughout the spectral region 0.68 to 2.5 micrometers. High correlations were found in appropriate regions for all three constituents, though that with stored energy is still considered tenuous. Quantitation was improved using 1st and 2nd derivative spectra. High resolution data over a broad spectral range would be required to quantitatively identify iron-bearing clays by remotely sensed reflectance.

  17. Photoluminescence, trap states and thermoluminescence decay ...

    Indian Academy of Sciences (India)

    Administrator

    Photoluminescence, trap states and thermoluminescence decay process study of Ca2MgSi2O7 : Eu. 2+. , Dy. 3+ phosphor. RAVI SHRIVASTAVA*, JAGJEET KAUR, VIKAS DUBEY and BEENA JAYKUMAR. Govt. VYT PG Autonomous College, Durg 491 001, (C.G.) India. MS received 9 July 2013; revised 5 December 2013.

  18. Thermoluminescence in some copper-doped compounds

    International Nuclear Information System (INIS)

    Patil, R.R.; Moharil, S.V.; Dhopte, S.M.; Muthal, P.L.; Kondawar, V.K.

    2003-01-01

    Thermoluminescence (TL) in various Cu + -doped materials is studied. A good correlation between the presence of copper in the Cu + form and TL sensitivity is observed. Correlation between TL emission spectra and photoluminescence suggests that Cu + acts as the emission center in the TL process. (copyright 2003 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  19. Rare earth oxyhalogenide base thermoluminescent material

    International Nuclear Information System (INIS)

    Rabatin, J.G.

    1976-01-01

    A process is described that consists to expose a thermoluminescent material to ionizing radiations, the material being a rare earth oxyhalogenide with terbium additions, to heat this material up to the emission of visible radiations and to measure the emitted radiations which are proportional to the ionizing radiation dose [fr

  20. Thermoluminescence of meteorites and their orbits

    Science.gov (United States)

    Melcher, C. L.

    1981-01-01

    The thermoluminescence levels of 45 ordinary chondrites are measured in order to provide information on the orbital characteristics of the meteorites before impact. Glow curves of the photon emission response of powdered samples of the meteorites to temperatures up to 550 C in the natural state and following irradiation by a laboratory test dose of 110,000 rad were obtained as functions of terrestrial age and compared to those of samples of the Pribram, Lost City and Innisfree meteorites, for which accurate orbital data is available. The thermoluminescence levels in 40 out of 42 meteorites are found to be similar to those of the three control samples, indicating that the vast majority of ordinary chondrites that survive atmospheric entry have perihelia in the range 0.8-1 AU. Of the remaining two, Farmville is observed to exhibit an unusually large gradient in thermoluminescence levels with sample depth, which may be a result of a temperature gradient arising in a slowly rotating meteorite. Finally, the thermoluminescence measured in the Malakal meteorite is found to be two orders of magnitude lower than control samples, which is best explained by thermal draining by solar heating in an orbit with a perihelion distance of 0.5 to 0.6 AU.

  1. Quality control of thermoluminesce personal dose monitoring

    International Nuclear Information System (INIS)

    Shang Aiguo; He Wenchang; Zhao Fengtao

    2006-01-01

    In order to evaluate the influence factor to thermoluminesce personal dose monitoring result, the every question that can appear based on the fact was analyzed. The results show that the detector, annealing, measuring process can influence the monitoring result. It gives some measures to enhance monitoring quality. (authors)

  2. Energy efficiency indicators for assessing construction systems storing renewable energy: Application to phase change material-bearing Façades

    OpenAIRE

    Tenorio Ríos, José Antonio; Sánchez-Ramos, José; Ruiz-Pardo, Álvaro; Álvarez, Servando; Cabeza, Luisa F.

    2015-01-01

    Assessing the performance or energy efficiency of a single construction element by itself is often a futile exercise. That is not the case, however, when an element is designed, among others, to improve building energy performance by harnessing renewable energy in a process that requires a source of external energy. Harnessing renewable energy is acquiring growing interest in Mediterranean climates as a strategy for reducing the energy consumed by buildings. When such reduction is oriented to...

  3. On the ability of some cyclic plasticity models to predict the evolution of stored energy in a type 304L stainless steel submitted to high cycle fatigue

    International Nuclear Information System (INIS)

    Vincent, L.

    2008-01-01

    Fatigue analyses of materials are generally based on a so-called stabilized cycle, on which plastic strain amplitude, plastic energy, maximum shear stress and so on are determined. The part of plastic energy which is dissipated in heat cannot be used to accumulate damage and it should be worthwhile extracting only the part of plastic energy which is stored in material microstructure in order to build a consistent damage model. In this paper, some cyclic plasticity models including a polycrystalline model are reformulated in the thermodynamic framework in order to test their capacity to predict both the stress-strain behaviour and the partition of plastic energy for a high cycle fatigue test on a type 304L stainless steel. For an equivalent description of stress-strain loops, the number of kinematic hardening variables chosen in a model may qualitatively alter the prediction of plastic energy partition due to the modification of the isotropic hardening variable. Measurements of the specimen temperature increase due to plastic dissipation is therefore proposed as a convenient complementary experimental data to identify the constitutive equation of the isotropic hardening variable of a cyclic plasticity model. (author)

  4. Balance of the stored energies sustained by the internal and edge transport barriers and effects of ELMs and L-H transitions in JT-60U

    International Nuclear Information System (INIS)

    Kamada, Y.; Yoshida, M.; Sakamoto, Y.; Koide, Y.; Oyama, N.; Urano, H.; Kamiya, K.; Suzuki, T.; Isayama, A.

    2009-01-01

    To understand key physics processes determining radial profiles of the kinetic plasma parameters in the advanced tokamak operation scenarios, correlations between the edge transport barrier (ETB) and the internal transport barrier (ITB) have been studied in the JT-60U tokamak device. It has been found that the edge pedestal poloidal beta, β p -ped, increases almost linearly with the total poloidal beta, β p -tot, over a wide range of the plasma current for type I ELMing H-mode plasmas, and this dependence becomes stronger with increasing triangularity. This dependence is not due to the profile stiffness, since the dependence is the same regardless of the existence of ITB. As the stored energy inside the ITB-foot radius (W ITB ) increases, the total thermal stored energy (W th ) increases and then the pedestal stored energy (W ped ) increases. On the other hand, as W ped increases, the ELM penetration expands more inwards and finally reaches the ITB-foot radius. At this situation, the ITB-foot radius cannot move outwards because of the erosion by ELMs. Then the fractions of W ITB /W th and W ped /W th become almost constant. It has also been found that the type I ELM expels/decreases the edge toroidal momentum larger than the edge ion thermal energy. The ELM penetration for the toroidal rotation tends to be deeper than that for the ion temperature and can exceed the ITB-foot radius. The ELM penetration is deeper for CO-rotating plasmas than CTR rotating plasmas. In both cases, the ELM penetration is deeper in the order of the toroidal rotation (V t ), the ion temperature (T i ) and then the electron temperature (T e ). The L-H transition also changes the V t profile more significantly than the T i profile. At the L-H transition, the pedestal V t shifts into the CTR-direction deeply and suddenly without a change in T i , and then the pedestal V t grows further together with a growth of the pedestal T i in a slower timescale. Such changes in V t by ELMs and L

  5. Thermoluminescent of induced calcite by gamma and ultraviolet radiation

    International Nuclear Information System (INIS)

    Lima, J.F. de.

    1987-01-01

    Samples of brazilian calcite, exposed to gamma radiation in laboratory and heated at constant rate of 2.7 0 C/s, showed three glow peaks at 150, 250 and 350 0 C in their thermoluminescent emission curves. The analysis of these peaks, using different models, indicated that they follow a second order kinetics; it has been obtained, for the activation energy, 1.3, 1.5 and 1.7 eV, and, for the pre-exponential factors, 8.1 x 10 14 , 6.8 x10 13 and 2.4 x 10 12 s -1 . Although the total thermoluminescent emission has stayed constant, the relative height of glow peaks has changed with the temperature of annealing in the range of 400 to 700 0 C. Exposed samples were also illuminated with ultraviolet light and the resultant curves showed partial or total bleaching or some glow peaks and the growth of peaks at lower temperatures. Samples of virgin calcite, submited to increasing exposures of gamma rays, showed a corresponding enhancement of the optical absorption bands in the range of 25000 to 47000 cm -1 A subsequent illumination of these samples with ultraviolet light produced a decrease of the optical absorption bands at the same range. (author) [pt

  6. Frequency Activated Fast Power Reserve for Wind Power Plant Delivered from Stored Kinetic Energy in the Wind Turbine Inertia

    DEFF Research Database (Denmark)

    Knüppel, Thyge; Thuring, P.; Kumar, S

    2011-01-01

    is proposed that delivers a short-term power reserve from the kinetic energy in the wind turbine (WT) inertia, while considering the inherent characteristics of a wind power plant. The aim is to contribute with a fast power reserve to stabilize the frequency drop during large and sudden production deficits......With increased penetration of converter interfaced generation, synchronous generators may start to be displaced to keep the overall power balance. As a consequence the resulting inertia in the system may decrease and make the power system more exposed to frequency excursions. Here, a control...

  7. Analytical Calculation of Stored Electrostatic Energy per Unit Length for an Infinite Charged Line and an Infinitely Long Cylinder in the Framework of Born-Infeld Electrostatics

    International Nuclear Information System (INIS)

    Fathi, F.; Moayedi, S. K.; Shafabakhsh, M.

    2015-01-01

    More than 80 years ago, Born-Infeld electrodynamics was proposed in order to remove the point charge singularity in Maxwell electrodynamics. In this work, after a brief introduction to Lagrangian formulation of Abelian Born-Infeld model in the presence of an external source, we obtain the explicit forms of Gauss’s law and the energy density of an electrostatic field for Born-Infeld electrostatics. The electric field and the stored electrostatic energy per unit length for an infinite charged line and an infinitely long cylinder in Born-Infeld electrostatics are calculated. Numerical estimations in this paper show that the nonlinear corrections to Maxwell electrodynamics are considerable only for strong electric fields. We present an action functional for Abelian Born-Infeld model with an auxiliary scalar field in the presence of an external source. This action functional is a generalization of the action functional which was presented by Tseytlin in his studies on low energy dynamics of D-branes (Nucl. Phys. B469, 51 (1996); Int. J. Mod. Phys. A 19, 3427 (2004)). Finally, we derive the symmetric energy-momentum tensor for Abelian Born-Infeld model with an auxiliary scalar field

  8. Final Report Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores in California. Predicted indoor air quality and energy consumption using a matrix of ventilation scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Apte, Michael G. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mendell, Mark J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sohn, Michael D. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Dutton, Spencer M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Berkeley, Pam M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Spears, Michael [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2011-02-01

    Through mass-balance modeling of various ventilation scenarios that might satisfy the ASHRAE 62.1 Indoor Air Quality (IAQ) Procedure, we estimate indoor concentrations of contaminants of concern (COCs) in California “big box” stores, compare estimates to available thresholds, and for selected scenarios estimate differences in energy consumption. Findings are intended to inform decisions on adding performance-based approaches to ventilation rate (VR) standards for commercial buildings. Using multi-zone mass-balance models and available contaminant source rates, we estimated concentrations of 34 COCs for multiple ventilation scenarios: VRmin (0.04 cfm/ft2 ), VRmax (0.24 cfm/ft2 ), and VRmid (0.14 cfm/ft2 ). We compared COC concentrations with available health, olfactory, and irritant thresholds. We estimated building energy consumption at different VRs using a previously developed EnergyPlus model. VRmax did control all contaminants adequately, but VRmin did not, and VRmid did so only marginally. Air cleaning and local ventilation near strong sources both showed promise. Higher VRs increased indoor concentrations of outdoor air pollutants. Lowering VRs in big box stores in California from VRmax to VRmid would reduce total energy use by an estimated 6.6% and energy costs by 2.5%. Reducing the required VRs in California’s big box stores could reduce energy use and costs, but poses challenges for health and comfort of occupants. Source removal, air cleaning, and local ventilation may be needed at reduced VRs, and even at current recommended VRs. Also, alternative ventilation strategies taking climate and season into account in ventilation schedules may provide greater energy cost savings than constant ventilation rates, while improving IAQ.

  9. CaSO4: Dy + Teflon thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Campos, L.L.

    1986-01-01

    A pellet dosemeter of CaSO 4 : Dy + Teflon was developed at IPEN. CaSO 4 : Dy thermoluminescent phosphor, grown in the Dosimetric Materials Production Laboratory was chosen, due to its high sensitivity, ease of preparation and comparatively low cost. Pellets were produced by cold pressing and sintering a mixture of CaSO 4 : Dy and Teflon powders. Extensive work was done to study in detail all CaSO 4 : Dy pellets characteristics from the point of view of dosimetry with the purpose of introducing it in the routine use. A filter combination providing an energy independent response from 20 KeV to 1,25 MeV was obtained. The dosemeter consists of three pellets sealed between two thin plastic sheets and placed under plastic and lead filters. The combination of these tree filters allows the exposure as well as the energy determination of an unknown source. (Author) [pt

  10. Microcomputer-controlled thermoluminescent analyser IJS MR-200; Mikroracunalniski termoluminescentni analizator IJS MR-200

    Energy Technology Data Exchange (ETDEWEB)

    Mihelic, M; Miklavzic, U; Rupnik, Z; Satalic, P; Spreizer, F; Zerovnik, I [Institut Jozef Stefan, Ljubljana (Yugoslavia)

    1985-07-01

    Performances and concept of the multipurpose, microcomputer-controlled thermoluminescent analyser, designed for use in laboratory work TL dosemeters as well as for routine dose readings in the range from ecological to accident doses is described. The main features of the analyser are: time-linear sampling, digitalisation, storing, and subsequent displaying on the monitor time scale of the glow and and temperature curve of the TL material; digital stabilization, control and diagnostic of the analog unit; ability of storing 7 different 8-parametric heating programs; ability of storing 15 evaluation programs defined by 2 or 4 parameters and 3 different algorithms (altogether 5 types of evaluations). Analyser has several features intended for routine work: 9 function keys and possibilities of file forming on cassette or display disc, of dose calculation and averaging, of printing reports with names, and possibility of additional programming in Basic. (author)

  11. Thermoluminescence of zirconium oxide nanostructured to mammography X-ray beams

    Energy Technology Data Exchange (ETDEWEB)

    Palacios, L.L. [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada-Legaria, IPN. Av. Legaria 694, 11500 Mexico D.F. (Mexico); Rivera, T., E-mail: trivera@ipn.mx [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada-Legaria, IPN. Av. Legaria 694, 11500 Mexico D.F. (Mexico); Roman, J. [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada-Legaria, IPN. Av. Legaria 694, 11500 Mexico D.F. (Mexico); Azorin, J. [Universidad Autonoma Metropolitana-Iztapalapa. Av. San Rafael Atlixco 187, 09340 Mexico D.F. (Mexico); Gaona, E. [Universidad Autonoma Metropolitana-Xochimilco. Calz. Del Hueso 1100, 04960 Mexico D.F. (Mexico)

    2012-07-15

    In the present work thermoluminescent (TL) response of zirconium oxide (ZrO{sub 2}) nanostructured induced by mammography X-ray radiation was investigated. Measurements were made of the response per unit air kerma of ZrO{sub 2} with mammography equipment parameters (semiautomatic exposure control, 24 kVp and 108 mAs). The calibration curves were obtained by simultaneously irradiating ZrO{sub 2} samples and ion chamber. Samples of ZrO{sub 2} showed a linear response as a function of entrance skin air kerma. The observed results in TL properties suggest that ZrO{sub 2} nanostructured could be considered as an effective material for X-ray beams dosimetry if appropriate calibration procedures are performed. - Highlights: Black-Right-Pointing-Pointer X-ray low energy thermoluminescent of ZrO{sub 2} dosimeter is developed. Black-Right-Pointing-Pointer Air kerma measurements were made by thermoluminescent dosimeter ZrO{sub 2} using mammography equipment parameters. Black-Right-Pointing-Pointer Entrance surface skin doses were made using thermoluminescent dosimeter of ZrO{sub 2} to X-ray beam quality control.

  12. Synthesis and thermoluminescence of LaAlO3:Pr3+ to UVC radiation dosimetry

    International Nuclear Information System (INIS)

    Morales-Hernández, A.; Zarate-Medina, J.; Contreras-García, M.E.; Azorín-Nieto, J.; Rivera-Montalvo, T.

    2016-01-01

    Thermoluminescent (TL) response of trivalent praseodymium ion doped lanthanum aluminate (LaAlO 3 :Pr 3+ ) obtained by Pechini method and Spray Dryer was studied. TL response of LaAlO 3 :Pr 3+ powders submitted at 1600 °C exhibited one peak centered at 157 °C. Sensitivity of LaAlO 3 :Pr 3+ was improved in around 90 times compared with undoped LaAlO 3 . TL response as a function of wavelength showed a maximum in 230 nm. Dosimetric characteristics of LaAlO 3 :Pr 3+ under UVR radiation effects were analyzed. Evaluation of activation energy was obtained by Glow Fit v.1.3 software. Experimental results about thermoluminescent characteristics of LaAlO 3 :Pr 3+ suggest as good candidate to be employed as a complementary thermoluminescent device with other TL phosphors as aluminum oxide - Highlights: • High sensitivity of new phosphor to UVC dosimetry was is studied. • Thermoluminescence response of LaAlO 3 :Pr 3+ is presented. • LaAlO 3 :Pr 3+ is suggested as UVCR dosimeter. • TL response of LaAlO 3 :Pr 3+ has dependence on sintering temperature.

  13. Thermoluminescence of zirconium oxide nanostructured to mammography X-ray beams

    International Nuclear Information System (INIS)

    Palacios, L.L.; Rivera, T.; Roman, J.; Azorín, J.; Gaona, E.

    2012-01-01

    In the present work thermoluminescent (TL) response of zirconium oxide (ZrO 2 ) nanostructured induced by mammography X-ray radiation was investigated. Measurements were made of the response per unit air kerma of ZrO 2 with mammography equipment parameters (semiautomatic exposure control, 24 kVp and 108 mAs). The calibration curves were obtained by simultaneously irradiating ZrO 2 samples and ion chamber. Samples of ZrO 2 showed a linear response as a function of entrance skin air kerma. The observed results in TL properties suggest that ZrO 2 nanostructured could be considered as an effective material for X-ray beams dosimetry if appropriate calibration procedures are performed. - Highlights: ► X-ray low energy thermoluminescent of ZrO 2 dosimeter is developed. ► Air kerma measurements were made by thermoluminescent dosimeter ZrO 2 using mammography equipment parameters. ► Entrance surface skin doses were made using thermoluminescent dosimeter of ZrO 2 to X-ray beam quality control.

  14. S961, an insulin receptor antagonist causes hyperinsulinemia, insulin-resistance and depletion of energy stores in rats

    Energy Technology Data Exchange (ETDEWEB)

    Vikram, Ajit [Department of Pharmacology and Toxicology, National Institute of Pharmaceutical Education and Research (NIPER), SAS Nagar, Mohali, Punjab 160 062 (India); Jena, Gopabandhu, E-mail: gbjena@gmail.com [Department of Pharmacology and Toxicology, National Institute of Pharmaceutical Education and Research (NIPER), SAS Nagar, Mohali, Punjab 160 062 (India)

    2010-07-23

    Research highlights: {yields}Insulin receptor antagonist S961 causes hyperglycemia, hyperinsulinemia and insulin resistance in rats. {yields}Peroxysome-proliferator-activated-receptor-gamma agonist pioglitazone improves S961 induced hyperglycemia and glucose intolerance. {yields}Long term treatment with insulin receptor antagonist S961 results in the decreased adiposity and hepatic glycogen content. {yields}Improvement in the hyperglycemia and glucose intolerance by pioglitazone clearly demonstrates that S961 treated rats can be successfully used to screen the novel therapeutic interventions having potential to improve glucose disposal through receptor independent mechanisms. -- Abstract: Impairment in the insulin receptor signaling and insulin mediated effects are the key features of type 2 diabetes. Here we report that S961, a peptide insulin receptor antagonist induces hyperglycemia, hyperinsulinemia ({approx}18-fold), glucose intolerance and impairment in the insulin mediated glucose disposal in the Sprague-Dawley rats. Further, long-term S961 treatment (15 day, 10 nM/kg/day) depletes energy storage as evident from decrease in the adiposity and hepatic glycogen content. However, peroxysome-proliferator-activated-receptor-gamma (PPAR{gamma}) agonist pioglitazone significantly (P < 0.001) restored S961 induced hyperglycemia (196.73 {+-} 16.32 vs. 126.37 {+-} 27.07 mg/dl) and glucose intolerance ({approx}78%). Improvement in the hyperglycemia and glucose intolerance by pioglitazone clearly demonstrates that S961 treated rats can be successfully used to screen the novel therapeutic interventions having potential to improve glucose disposal through receptor independent mechanisms. Further, results of the present study reconfirms and provide direct evidence to the crucial role of insulin receptor signaling in the glucose homeostasis and fuel metabolism.

  15. S961, an insulin receptor antagonist causes hyperinsulinemia, insulin-resistance and depletion of energy stores in rats

    International Nuclear Information System (INIS)

    Vikram, Ajit; Jena, Gopabandhu

    2010-01-01

    Research highlights: →Insulin receptor antagonist S961 causes hyperglycemia, hyperinsulinemia and insulin resistance in rats. →Peroxysome-proliferator-activated-receptor-gamma agonist pioglitazone improves S961 induced hyperglycemia and glucose intolerance. →Long term treatment with insulin receptor antagonist S961 results in the decreased adiposity and hepatic glycogen content. →Improvement in the hyperglycemia and glucose intolerance by pioglitazone clearly demonstrates that S961 treated rats can be successfully used to screen the novel therapeutic interventions having potential to improve glucose disposal through receptor independent mechanisms. -- Abstract: Impairment in the insulin receptor signaling and insulin mediated effects are the key features of type 2 diabetes. Here we report that S961, a peptide insulin receptor antagonist induces hyperglycemia, hyperinsulinemia (∼18-fold), glucose intolerance and impairment in the insulin mediated glucose disposal in the Sprague-Dawley rats. Further, long-term S961 treatment (15 day, 10 nM/kg/day) depletes energy storage as evident from decrease in the adiposity and hepatic glycogen content. However, peroxysome-proliferator-activated-receptor-gamma (PPARγ) agonist pioglitazone significantly (P < 0.001) restored S961 induced hyperglycemia (196.73 ± 16.32 vs. 126.37 ± 27.07 mg/dl) and glucose intolerance (∼78%). Improvement in the hyperglycemia and glucose intolerance by pioglitazone clearly demonstrates that S961 treated rats can be successfully used to screen the novel therapeutic interventions having potential to improve glucose disposal through receptor independent mechanisms. Further, results of the present study reconfirms and provide direct evidence to the crucial role of insulin receptor signaling in the glucose homeostasis and fuel metabolism.

  16. Energy Efficiency Indicators for Assessing Construction Systems Storing Renewable Energy: Application to Phase Change Material-Bearing Façades

    Directory of Open Access Journals (Sweden)

    José A. Tenorio

    2015-08-01

    Full Text Available Assessing the performance or energy efficiency of a single construction element by itself is often a futile exercise. That is not the case, however, when an element is designed, among others, to improve building energy performance by harnessing renewable energy in a process that requires a source of external energy. Harnessing renewable energy is acquiring growing interest in Mediterranean climates as a strategy for reducing the energy consumed by buildings. When such reduction is oriented to lowering demand, the strategy consists in reducing the building’s energy needs with the use of construction elements able to passively absorb, dissipate, or accumulate energy. When reduction is pursued through M&E services, renewable energy enhances building performance. The efficiency of construction systems that use renewable energy but require a supplementary power supply to operate can be assessed by likening these systems to regenerative heat exchangers built into the building. The indicators needed for this purpose are particularly useful for designers, for they can be used to compare the efficiency or performance to deliver an optimal design for each building. This article proposes a series of indicators developed to that end and describes their application to façades bearing phase change materials (PCMs.

  17. A microcomputer controlled thermoluminescence dosimetry system

    International Nuclear Information System (INIS)

    Huyskens, C.J.; Kicken, P.J.H.

    1980-01-01

    Using a microcomputer, an automatic thermoluminescence dosimetry system for personal dosimetry and thermoluminescence detector (TLD) research was developed. Process automation, statistical computation and dose calculation are provided by this microcomputer. Recording of measurement data, as well as dose record keeping for radiological workers is carried out with floppy disk. The microcomputer also provides a human/system interface by means of a video display and a printer. The main features of this dosimetry system are its low cost, high degree of flexibility, high degree of automation and the feasibility for use in routine dosimetry as well as in TLD research. The system is in use for personal dosimetry, environmental dosimetry and for TL-research work. Because of its modular set-up several components of the system are in use for other applications, too. The system seems suited for medium sized health physics groups. (author)

  18. Thermoluminescence dosimetry in Northwest Puerto Rico

    International Nuclear Information System (INIS)

    Block, A.M.; Clements, R.G.; Rosa, L.I.; Santos, F.

    1975-01-01

    In October, 1973, the Puerto Rico Water Resources Authority sought the initiation of studies aimed at determining background radiological characteristics of the northwestern quadrant of Puerto Rico using thermoluminescent dosemeters. Some of the studies were required for supporting data for the environmental report submitted as part of the licensing procedure in the establishment of thermonuclear electric power generation facilities in Barrio Islote, Arecibo, Puerto Rico. Previous studies of radiological characteristics of the area had been made using sodium iodide sensing equipment in an airplane flying at an altitude of 500 ft. The results are expressed in counts per second, and provide useful comparative levels for radioactivity measured with the thermoluminescent detectors. (U.S.)

  19. Measurement of the dose by dispersed radiation in a lineal accelerator using thermoluminescent dosimeters of CaSO4:Dy

    International Nuclear Information System (INIS)

    Chavez C, N.; Torijano, E.; Azorin, J.; Herrera, A.

    2014-08-01

    The thermoluminescence (Tl) is based on the principle of the luminescent in a material when is heated below their incandescence temperature. Is a technique very used in dosimetry that is based on the property that have most of the crystalline materials regarding the storage of the energy that they absorb when are exposed to the ionizing radiations. When this material has been irradiated previously, the radioactive energy that contains is liberated in form of light. In general, the principles that govern the thermoluminescence are in essence the same of those responsible for all the luminescent processes and, this way, the thermoluminescence is one of the processes that are part of the luminescence phenomenon. For this work, the dispersed radiation was measured in the therapy area of the lineal accelerator of medical use type Elekta, using thermoluminescent dosimeters of CaSO 4 :Dy + Ptfe developed and elaborated in the Universidad Autonoma Metropolitana, Unidad Iztapalapa. With the dosimeters already characterized and calibrated, we proceeded to measure the dispersed radiation being a patient in treatment. The results showed values for the dispersed radiation the order of a third of the dose received by the patient on the treatment table at 30 cm of the direct beam and the order of a hundredth in the control area (4 m of the direct beam, approximately). The conclusion is that the thermoluminescent dosimeters of CaSO 4 : Dy + Ptfe are appropriate to measure dispersed radiation dose in radiotherapy. (author)

  20. Image in nuclear dosimetry using thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Guinsburg, G.; Matsuoka, M.; Watanabe, S.

    1987-01-01

    A low cost methodology to produce images of internal sick organs by radioisotopic intake, is presented. Dosimetries of thermoluminescent material and Teflon (ratio:50%) in bidimensional matrix shape are used with a Pb collimator. This collimator-bidimensional matrix system was tested ''in vivo'' and in thyroid phantoms using 99m Tc. A comparative evaluation between this method and the scintigraphy one is presented. (M.A.C.) [pt

  1. Needle-type differential thermoluminescent dosemeter

    International Nuclear Information System (INIS)

    Kubu, M.

    1988-01-01

    The dosemeter serves to measure the depth distribution of absorbed dose in a phantom in mixed neutron and gamma radiation fields. It consists of a stratified cylindrical absorber in which alternate moderator and cadmium layers. Inside are two bores along the longitudinal axis for tubes filled with 6 LiF and 7 LiF powder thermoluminescent dosemeters. The device is easily portable and allows to carry out measurements with a high level of reproducibility. (J.B.). 4 figs

  2. Method of preparing a thermoluminescent phosphor

    Science.gov (United States)

    Lasky, Jerome B.; Moran, Paul R.

    1979-01-01

    A thermoluminescent phosphor comprising LiF doped with boron and magnesium is produced by diffusion of boron into a conventional LiF phosphor doped with magnesium. Where the boron dopant is made to penetrate only the outer layer of the phosphor, it can be used to detect shallowly penetrating radiation such as tritium beta ays in the presence of a background of more penetrating radiation.

  3. TO STORES USERS

    CERN Multimedia

    SPL Division

    2001-01-01

    Stores users are informed that the Stores (Central, Emergency window, Raw materials, Chemical products and Prévessin Self service stores) will be closed on Friday, 7 December owing to migration of the Stores computers to Windows 2000. Thank you for your understanding.

  4. Personnel radiation monitoring by thermoluminescence dosimetry (2000-2001)

    International Nuclear Information System (INIS)

    Mi-Cho-Cho, Daw; Hla-Hla-Win, Daw; Thin-Thin-Kraing

    2001-01-01

    Thermoluminescence dosimetry service was introduced in 1991. Personnel who exposed directly or indirectly to radiation is monitored by thermoluminescent dosimeter. TL materials used for thermoluminescent dosimeter are in the form of thin disc. Personnel whole-body and extremity doses are measured by thermoluminescence dosimetry. The Harshaw Model 4500 TLD reader and Vinten 654E TLD reader are used for TLD evaluation. At present about 600 radiation workers are provided with TLD for routine monitoring. It was found that most personnel had received within permissible dose recommended by the International Commission on Radiological Protection (ICRP). (author)

  5. Thermoluminescence characterisation of chemical vapour deposited diamond films

    CERN Document Server

    Mazzocchi, S; Bucciolini, M; Cuttone, G; Pini, S; Sabini, M G; Sciortino, S

    2002-01-01

    The thermoluminescence (TL) characteristics of a set of six chemical vapour deposited diamond films have been studied with regard to their use as off-line dosimeters in radiotherapy. The structural characterisation has been performed by means of Raman spectroscopy. Their TL responses have been tested with radiotherapy beams ( sup 6 sup 0 Co photons, photons and electrons from a linear accelerator (Linac), 26 MeV protons from a TANDEM accelerator) in the dose range 0.1-7 Gy. The dosimetric characterisation has yielded a very good reproducibility, a very low dependence of the TL response on the type of particle and independence of the radiation energy. The TL signal is not influenced by the dose rate and exhibits a very low thermal fading. Moreover, the sensitivity of the diamond samples compares favourably with that of standard TLD100 dosimeters.

  6. Dating of Chichen Itza ceramics by the method of thermoluminescence

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.; Mendoza A, D.; Cuapio O, L.A.; Ramirez L, A.; Schaaf, P.; Chung, H.

    2005-01-01

    In this work we present some results about thermoluminescent dating of some archaeological ceramic samples belonging to Chichen Itza, Yucatan, Mexico: CH11, CH13, CH14 and CH15. The analysis was realized using the fine grained mode in a Daybreak model 1100 reader Tl System. The radioisotopes that contribute in the accumulate annual dose in ceramic samples ( 40 K, 238 U, 232 Th) were determined by means of techniques such as Energy Dispersive X-ray Spectroscopy (EDS) and Neutron Activation Analysis (NAA), while the artificial irradiation of samples was carried out with a 90 Sr source beta radiation. The resulting mean CH11 ceramic sample was 934 ±45 years old, CH13 was 465 ± 26, CH14 was 888 ± 34 and CH15 was 867 ± 42. These results are in agreement with results obtained through other methods. (Author)

  7. Thermoluminescence in medical dosimetry; Termoluminiscencia en dosimetria medica

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, T., E-mail: trivera@ipn.mx [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico)

    2011-10-15

    The dosimetry by thermoluminescence (Tl) is applied in the entire world for the dosimetry of ionizing radiations specially to personal and medical dosimetry. This dosimetry method has been very interesting for measures in vivo because the Tl dosimeters have the advantage of being very sensitive in a very small volume and they are also equivalent to tissue and they do not need additional accessories (for example, cable, electrometer, etc.) The main characteristics of the diverse Tl materials to be used in the radiation measures and practical applications are: the Tl curve, the share homogeneity, the signal stability after the irradiation, precision and exactitude, the response in function with the dose and the energy influence. In this work a brief summary of the advances of the radiations dosimetry is presented by means of the thermally stimulated luminescence and its application to the dosimetry in radiotherapy. (Author)

  8. Photoluminescence and thermoluminescence properties of ...

    Indian Academy of Sciences (India)

    WINTEC

    The dependence of TL of β-TCP : Dy on the energy and dose of radiation, and on the doping concentration were studied. ... combination of thermally released electrons or holes from ... in the wake of widespread use of X-rays in the diagnostic.

  9. The stored energy in processed Cu-0.4 wt.%Cr-0.12 wt.%Zr-0.02 wt.%Si-0.05 wt.%Mg

    International Nuclear Information System (INIS)

    Li, X.F.; Dong, A.P.; Wang, L.T.; Yu, Z.; Meng, L.

    2011-01-01

    Research highlights: → The crystal orientation in processed Cu-0.4 wt.%Cr-0.12 wt.%Zr-0.02 wt.%Si-0.05 wt.%Mg is deviating from the as-cast specimens and microstrain of the alloy is gradually increasing as the draw ratio rising before η ≤ 6.7. → The dynamic recovery has taken place as 6.7 texture is formed with the draw ratio rising. Meanwhile, the stored energy also increases with the draw ratio rising and a peak is reached with draw ratio of 6.7. The release of stored energy is primarily due to the decrease of dislocation density. The flow stress estimated from the stored energy has a similar variation trend with the measured data with a stress difference ∼20 to 120 MPa. The main strengthening effect is attributed to dislocation mechanism.

  10. Influência da dependência energética de dosímetros termoluminescentes na medida da dose na entrada da pele em procedimentos radiográficos Influence of thermoluminescent dosimeters energy dependence on the measurement of entrance skin dose in radiographic procedures

    Directory of Open Access Journals (Sweden)

    Mércia Liane de Oliveira

    2010-04-01

    Full Text Available OBJETIVO: O objetivo do presente trabalho foi avaliar a influência da dependência energética de materiais termoluminescentes na determinação da dose na entrada da pele de pacientes submetidos a exames radiográficos (radiologia geral, mamografia e radiologia odontológica. MATERIAIS E MÉTODOS: Três diferentes materiais termoluminescentes foram utilizados: LiF:Mg,Ti, LiF:Mg,Cu,P e CaSO4:Dy. Estes materiais foram expostos a fontes padronizadas de radiação X e gama, e a feixes clínicos de raios X. RESULTADOS: As curvas de calibração e de dependência energética foram obtidas. Todos os materiais apresentaram resposta linear em função do kerma no ar. Com relação à dependência energética, as amostras de CaSO4:Dy e LiF:Mg,Ti mostraram maior variação da resposta termoluminescente em função da energia efetiva do feixe de radiação. CONCLUSÃO: Os materiais testados mostraram desempenho adequado para a detecção da radiação X em feixes padronizados e clínicos. Embora as amostras de CaSO4:Dy e LiF:Mg,Ti apresentem dependência energética significativa no intervalo de energia considerado, este materiais podem ser utilizados para medição da dose de entrada na pele se fatores de correção apropriados forem utilizados.OBJECTIVE: This study was aimed at evaluating the influence of the energy dependence of thermoluminescent materials on the determination of entrance skin dose in patients submitted to conventional radiographic studies (general radiology, mammography and dental radiology. MATERIALS AND METHODS: Three different thermoluminescent materials were utilized: LiF:Mg,Ti, LiF:Mg,Cu,P and CaSO4:Dy. These materials were exposed to standardized sources of X and gamma radiation and clinical X-ray beams. RESULTS: Calibration and energy dependence curves were obtained. All the materials showed a linear response as a function of the air kerma. As far as energy dependence is concerned, the CaSO4:Dy and LiF:Mg,Ti samples showed the

  11. Application of thermoluminescence measurements to detect irradiated strawberries

    International Nuclear Information System (INIS)

    Heide, L.; Guggenberger, R.; Bogl, K.W.

    1990-01-01

    The thermoluminescence intensity of unirradiated and irradiated strawberries was studied with regard to dose response, storage time, and different varieties. An identification method could finally be developed. Further investigations were carried out to determine the origin of the thermoluminescence effect, which was found to be attributable to mineral grains adhering to the sample surface

  12. Detection of the irradiated domestic potato by thermoluminescence analysis

    International Nuclear Information System (INIS)

    Nakauma, M.; Saitou, K.; Todoriki, S.

    2004-01-01

    The applicability of thermoluminescence (TL) method to the detection of Japanese domestic potatoes was examined. Potatoes of nine different origins were exposed to gamma rays at O to 150Gy and the minerals separated from the potatoes were subjected to the TL measurements. The fading effects of TL emission intensity were also examined during the storage of post-irradiation period. The irradiated samples gave large intensity of TL signals compared with those of non-irradiated ones, and there were proportionalities in the intensity and the dose. The quantum yield of the TL emission for each unit weight and shape of glow curves were varied in the samples from different producing regions hence the irradiated samples were difficult to be detected by using those parameters. TL ratios obtained from the irradiated samples in all regions were 0.15-1.00 and those obtained from non-irradiated samples were less than 0.15. Therefore, the irradiated and non-irradiated samples can be distinguished by normalization (TL ratio). The signal intensity decreased with the storage time, and the reduction of signal was more rapidly observed in the sample stored under light condition than that in darkness. However, the TL ratio of the samples irradiated at 150 Gy and stored for five months could be distinguished from those of non-irradiated samples. It was also possible to apply this method to the detection of the domestic potatoes which irradiated in a commercial facility and purchased at a local market. (Received Oct. 22, 2003; Accepted Mar. 18, 2004)

  13. Reactor Gamma Heat Measurements with Calorimeters and Thermoluminescence Dosimeters

    DEFF Research Database (Denmark)

    Haack, Karsten; Majborn, Benny

    1973-01-01

    Intercomparison measurements of reactor γ-ray heating were carried out with calorimeters and thermoluminescence dosimeters. Within the measurement uncertainties the two methods yield coincident results. In the actual measurement range thermoluminescence dosimeters are less accurate than calorimet......Intercomparison measurements of reactor γ-ray heating were carried out with calorimeters and thermoluminescence dosimeters. Within the measurement uncertainties the two methods yield coincident results. In the actual measurement range thermoluminescence dosimeters are less accurate than...... calorimeters, but possess advantages such as a small probe size and the possibility of making simultaneous measurements at many different positions. Hence, thermoluminescence dosimeters may constitute a valuable supplement to calorimeters for reactor γ-ray heating measurements....

  14. Thermoluminescent response of LaAlO3:Pr

    International Nuclear Information System (INIS)

    Morales H, A.; Zarate M, J.; Azorin N, J.; Rivera M, T.

    2015-10-01

    In this study, the thermoluminescence response of doped lanthanum aluminate (LaAlO 3 ) with praseodymium ion (Pr) obtained by the Pechini method and drying by the spraying technique Spry Dryer was studied. The obtained powders were analyzed structurally by the X-ray diffraction technique; the morphological characterization was by the scanning electron microscopy technique. The obtained powders at 800 degrees C presented crystallinity and showed a Rhombohedral crystal structure, this phase was observed by X-ray diffraction patterns. Thermoluminescence response of LaAlO 3 :Pr showed a brightness curve with a peak centered at 157 degrees C. The sensitivity of the doped samples was improved about 90 times in comparison with the undoped sample. Thermoluminescence response in function of the wavelength showed a maximum at 230 nm, reproducibility of thermoluminescence response was ±50%. Also the fading in thermoluminescence response was studied. (Author)

  15. Positional glow curve simulation for thermoluminescent detector (TLD) system design

    International Nuclear Information System (INIS)

    Branch, C.J.; Kearfott, K.J.

    1999-01-01

    Multi- and thin element dosimeters, variable heating rate schemes, and glow-curve analysis have been employed to improve environmental and personnel dosimetry using thermoluminescent detectors (TLDs). Detailed analysis of the effects of errors and optimization of techniques would be highly desirable. However, an understanding of the relationship between TL light production, light attenuation, and precise heating schemes is made difficult because of experimental challenges involved in measuring positional TL light production and temperature variations as a function of time. This work reports the development of a general-purpose computer code, thermoluminescent detector simulator, TLD-SIM, to simulate the heating of any TLD type using a variety of conventional and experimental heating methods including pulsed focused or unfocused lasers with Gaussian or uniform cross sections, planchet, hot gas, hot finger, optical, infrared, or electrical heating. TLD-SIM has been used to study the impact on the TL light production of varying the input parameters which include: detector composition, heat capacity, heat conductivity, physical size, and density; trapped electron density, the frequency factor of oscillation of electrons in the traps, and trap-conduction band potential energy difference; heating scheme source terms and heat transfer boundary conditions; and TL light scatter and attenuation coefficients. Temperature profiles and glow curves as a function of position time, as well as the corresponding temporally and/or spatially integrated glow values, may be plotted while varying any of the input parameters. Examples illustrating TLD system functions, including glow curve variability, will be presented. The flexible capabilities of TLD-SIM promises to enable improved TLD system design

  16. Practical use of LiF-Nuclemon as a thermoluminescent dosemeter of γ, χ and β radiations

    International Nuclear Information System (INIS)

    Marilac Pereira Dolabela, L. de.

    1987-01-01

    The practical use of doped LiF Nuclemon with magnesium (LiF:Mg) as a thermoluminescent dosimeter of γ, X and β radiations is studied. The TL properties of LiF:Mg were analysed to γ energy of 1,25 MeV; 30, 50 and 70 KeV. (author)

  17. An experimental system for thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Perry, K.E.G.; George, E.

    1965-08-01

    A thermoluminescent dosimeter (T.L.D.) reader has been developed for experimental investigations on the use of lithium fluoride for 'finger tip' dosimetry. The design of the reader is based on the maximum use of standard electronic units in the A.E.R.E. Type 2000 series but some new unit development has been necessary. The reader gives improved experimental facilities over present commercially-available designs. The technique for 'finger-tip' dosimetry is described and the initial experimental results are given. (author)

  18. Thermoluminescence dating of some Hungarian medieval churches

    International Nuclear Information System (INIS)

    Kasa, I.; Bajnoczy, G.

    1984-01-01

    Thermoluminescence dating of three Hungarian historic churches was performed using the quarz inclusion technique and sup(60)Co gamma irradiation. Quarz grains obtained from the bricks were irradiated and the radiation doses were measured by CaSOsub(4):Dy TL dosemeters. Glow curves of irradiated and non-irradiated samples were also measured. From the results it was concluded that the ages of two churches were 10 and 30 percent less, respectively, than the ages estimated earlier. The age of the third church proved to be correct. (R.P.)

  19. Accuracy and precision in thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    Marshall, T.O.

    1984-01-01

    The question of accuracy and precision in thermoluminescent dosimetry, particularly in relation to lithium fluoride phosphor, is discussed. The more important sources of error, including those due to the detectors, the reader, annealing and dosemeter design, are identified and methods of reducing their effects on accuracy and precision to a minimum are given. Finally, the accuracy and precision achievable for three quite different applications are discussed, namely, for personal dosimetry, environmental monitoring and for the measurement of photon dose distributions in phantoms. (U.K.)

  20. Thermoluminescent dosimetry for LDEF experiment M0006

    International Nuclear Information System (INIS)

    Chang, J.Y.; Giangano, D.; Kantorcik, T.; Stauber, M.; Snead, L.

    1992-01-01

    Experiment M0006 on the Long Duration Exposure Facility had as its objective the investigation of space radiation effects on various electronic and optical components, as well as on seed germination. The Grumman Corporate Research Center provided the radiation dosimetric measurements for M0006, comprising the preparation of thermoluminescent dosimeters (TLD) and the subsequent measurement and analysis of flight exposed and control samples. In addition, various laboratory exposures of TLD's with gamma rays and protons were performed to obtain a better understanding of the flight exposures

  1. Thermoluminescent relative efficiencies of TLD-100 for nitrogen ions respect of gamma radiation

    International Nuclear Information System (INIS)

    Concha S, K.; Avila, O.; Gamboa de Buen, I.; Rodriguez V, M.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E.

    2004-01-01

    The purpose of this work is to measure the thermoluminescent relative efficiency of those TLD-100 dosemeters irradiated with nitrogen ions with respect to the gamma radiation of 60 Co, in function of the linear energy transfer (LET). Two energy of such nitrogen ions were selected that has the same value from LET when impacting in the dosemeters but with E 1 energy (4.8 MeV) and E 2 (9.95 MeV) smaller and greater respectively that the energy of the Bragg peak. (Author)

  2. NACS Store Planning Manual.

    Science.gov (United States)

    College Store Journal, 1979

    1979-01-01

    Topics discussed by the NACS Store Planning/Renovation Committees in this updated version of the college store renovation manual include: short- and long-range planning, financial considerations, professional planning assistance, the store's image and business character, location considerations, building requirements, space requirements, fixtures,…

  3. Thermoluminescent dosimetry of UV light using ZrO2:Gd films

    International Nuclear Information System (INIS)

    Flores D, R.C.; Rivera M, T.; Azorin N, J.; Falcony G, C.; Garcia H, M.; Martinez S, E.

    2002-01-01

    The samples used for the study are films of zirconium oxide activated with gadolinium (ZrO 2 :Gd) deposited in a glass substrate of square shape, whose dimensions are 1.5 mm thickness and 5 x 5 mm. The Tl curve of ZrO 2 :Gd presented two peaks in 110 and 290 Centigrade degrees. The thermoluminescent response depending on the wavelength presented a maximum in 270 nm. The treatment of optimum thermal erased was obtained for a temperature of 250 Centigrade degrees during 10 minutes. The irradiation time was realized in an interval of 1 to 75 minutes presenting its linear response until a time of 60 minutes. The recurring of the Tl response presented a variation of 1.38% with respect to the average. The fade out of the stored information in the material is 11.11% of standard deviation by a stored period of 7 days in normal working conditions. (Author)

  4. Thermoluminescence dosimetry materials: properties and uses

    International Nuclear Information System (INIS)

    McKeever, S.W.S.; Moscovitch, M.; Townsend, P.D.

    1995-01-01

    This book selects a range of the most popular thermoluminescence dosemeter (TLD) materials in use today and provides a critical account of their thermoluminescence (TL) and dosimetric properties. The information provided includes in-depth discussions of TL mechanisms, including an account of luminescence properties, and relevant information regarding dosimetric characteristics. The book is intended for those involved in TLD materials research, and for technicians and workers involved in the practical application of these materials in TL dosimetry. The advent of modern spectroscopic methods for measuring TL emission spectra (the so-called ''3-D'' presentation) seemed to the authors to be an invitation to compile such spectra for all the major TLD materials. Further consideration led to an expansion of the initial idea to include a compilation of dosimetric properties. One intention is to provide a synopsis of the TL and dosimetric properties of the most widely used TLD materials currently available and to form a link between the solid state defect properties of these materials and their actual dosimetric properties. A second intention is to provide a solid framework from which future studies of TLD materials could be launched. Too often in the past research into TLD materials has been haphazard, to say the least. By illustrating the links between solid state physics and the radiation dosimetry properties of these materials the book points to the future and to the pressing need for enhanced research on TLD materials. (Author)

  5. The Properties of CaSO{sub 4}: Mn Thermoluminescence Dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Bjaerngard, Bengt

    1963-06-15

    The properties of the radio thermoluminescence of CaSO{sub 4}:Mn, used for dosimetry of gamma and roentgen radiation, have been investigated. The light yield of the luminophore has been determined to 1.5 percent for 1 MeV gamma radiation. The dependence of the thermoluminescence light sum on the exposure, the exposure rate, and the exposure time can qualitatively be described by the first order process model, modified by a broad energy distribution of the electron trap depths. Some applications are discussed. The cheapness of the dosimeters, the convenient read-out, and the broad range of measurable exposures suggest that CaSO{sub 4}:Mn can be a valuable complement to other dosimetry systems.

  6. On the phototransferred thermoluminescence in MgB4O7:Dy

    International Nuclear Information System (INIS)

    Richmond, R.G.

    1987-01-01

    On exposure to ionizing radiations, the normal traps in MgB 4 0 7 :Dy can be emptied by the readout process only or by annealing at suitable temperatures, leaving the deep traps still intact. Subsequently, it is possible to repopulate the dosimetric peak by illuminating with u.v. light. Charge carriers released from the traps during the second readout give rise to a thermoluminescent output proportional to the ionizing radiation exposure and the u.v. radiant energy. This is called phototransferred thermoluminescence (PTTL). The PTTL method can be utilized for the reassessment of the initial γ-ray exposure. This paper presents the measurements of the intrinsic response of the commercially available MgB 4 0 7 :Dy to u.v. radiation, with a demonstration of its use for γ-ray dose re-estimation using the PTTL technique. (author)

  7. The initial rise method extended to multiple trapping levels in thermoluminescent materials

    Energy Technology Data Exchange (ETDEWEB)

    Furetta, C. [CICATA-Legaria, Instituto Politecnico Nacional, 11500 Mexico D.F. (Mexico); Guzman, S. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, A.P. 70-543, 04510 Mexico D.F. (Mexico); Ruiz, B. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, A.P. 70-543, 04510 Mexico D.F. (Mexico); Departamento de Agricultura y Ganaderia, Universidad de Sonora, A.P. 305, 83190 Hermosillo, Sonora (Mexico); Cruz-Zaragoza, E., E-mail: ecruz@nucleares.unam.m [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, A.P. 70-543, 04510 Mexico D.F. (Mexico)

    2011-02-15

    The well known Initial Rise Method (IR) is commonly used to determine the activation energy when only one glow peak is presented and analysed in the phosphor materials. However, when the glow peak is more complex, a wide peak and some holders appear in the structure. The application of the Initial Rise Method is not valid because multiple trapping levels are considered and then the thermoluminescent analysis becomes difficult to perform. This paper shows the case of a complex glow curve structure as an example and shows that the calculation is also possible using the IR method. The aim of the paper is to extend the well known Initial Rise Method (IR) to the case of multiple trapping levels. The IR method is applied to minerals extracted from Nopal cactus and Oregano spices because the thermoluminescent glow curve's shape suggests a trap distribution instead of a single trapping level.

  8. The initial rise method extended to multiple trapping levels in thermoluminescent materials.

    Science.gov (United States)

    Furetta, C; Guzmán, S; Ruiz, B; Cruz-Zaragoza, E

    2011-02-01

    The well known Initial Rise Method (IR) is commonly used to determine the activation energy when only one glow peak is presented and analysed in the phosphor materials. However, when the glow peak is more complex, a wide peak and some holders appear in the structure. The application of the Initial Rise Method is not valid because multiple trapping levels are considered and then the thermoluminescent analysis becomes difficult to perform. This paper shows the case of a complex glow curve structure as an example and shows that the calculation is also possible using the IR method. The aim of the paper is to extend the well known Initial Rise Method (IR) to the case of multiple trapping levels. The IR method is applied to minerals extracted from Nopal cactus and Oregano spices because the thermoluminescent glow curve's shape suggests a trap distribution instead of a single trapping level. Copyright © 2010 Elsevier Ltd. All rights reserved.

  9. The initial rise method extended to multiple trapping levels in thermoluminescent materials

    International Nuclear Information System (INIS)

    Furetta, C.; Guzman, S.; Ruiz, B.; Cruz-Zaragoza, E.

    2011-01-01

    The well known Initial Rise Method (IR) is commonly used to determine the activation energy when only one glow peak is presented and analysed in the phosphor materials. However, when the glow peak is more complex, a wide peak and some holders appear in the structure. The application of the Initial Rise Method is not valid because multiple trapping levels are considered and then the thermoluminescent analysis becomes difficult to perform. This paper shows the case of a complex glow curve structure as an example and shows that the calculation is also possible using the IR method. The aim of the paper is to extend the well known Initial Rise Method (IR) to the case of multiple trapping levels. The IR method is applied to minerals extracted from Nopal cactus and Oregano spices because the thermoluminescent glow curve's shape suggests a trap distribution instead of a single trapping level.

  10. Influence of thermoluminescence trapping parameter from abundant quartz powder on equivalent dose

    International Nuclear Information System (INIS)

    Zhao Qiuyue; Wei Mingjian; Song Bo; Pan Baolin; Zhou Rui

    2014-01-01

    Glow curves of abundant quartz powder were obtained with the RGD-3B thermoluminescence (TL) reader. TL peaks with 448, 551, 654, 756 K were identified at the heating rate of 5 K/s. The activation energy, frequency factor and lifetime of trapped charge were evaluated at ambient temperature for four peaks by the method of various heating rates. Within a certain range of activation energy, the equivalent dose increases exponentially with the activation energy. The equivalent dose increases from 54 Gy to 485 Gy with the temperature from 548 K to 608 K, and it fluctuates around 531 Gy with the temperature from 608 K to 748 K. (authors)

  11. Comparative study of thermoluminescent, radiophotoluminescent and photographic dosemeters

    International Nuclear Information System (INIS)

    Deus, S.F.

    1976-01-01

    Comparison was made between the response of three differents dosimetric systems, namely, photographic, thermoluminescent (TL) and radiophotoluminescent (RPL). The comparison was divided in two parts. The first was carried out in known radiation conditions (exposure, normal incidence, energy) and under controlled environment (approximately 27 0 C temperature, approximately 70% relative humidity). Under these conditions, the response as a function of exposure and energy, the relation of the linearity to the energy, the lowest detectable exposure, and the reproducibility, were studied. The response against esposure at 37 KeVef and at 1 MeV was found to be linear in the region of interest to routine personnel dosimetry for all dosimeters except for the filmes. In the second part, the relative response of the dosimeters was verified under the uncontrolled conditions of personnel dosimetry. As the CaSO 4 :Dy is the most sensitive dosimeter, comparison was made using this dosimeter as the standard, in which case one finds that 20 of 29 TLD-100 dosimeters give the same reading within 30%, 13 of 29 RPL dosimeters agree within 30%, and only 3 of 29 films fall within 30% [pt

  12. Work place monitoring in accelerator facilities using thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Ribeiro, M.S.; Sanches, M.P.; Osima, A.M.; Rodriguez, D.L.; Carvalho, R.N.; Somessari, R.N.

    1998-01-01

    The increase in the use of large amounts of energy and large particles accelerators in development or in industrial processes for the reticulation, polymerization and sterilization of cables and wires allowed to discover and monitor work places in facilities having particle accelerators at the Institute of Energy and Nuclear Inquiries Comissao National de Energy Nuclear. Measures previously taken by technicians in routine monitoring, show that radiation doses found in the beams tube and at the door of the accelerator area is high enough to require routine programs to monitor work places at the installation. That is why, fifteen thermoluminescent dosimeters (TLD) where placed in different points of the facility where doses must be measured along a three month period and at the same time readings must be taken from control dosimeters kept within a shielded container. The monitor had a small double layer with three pellets of TLD CaSO4 Dy inside of a route carrier adopted in routine workers dosimetry usually. Outcomes show that the radiological protection program must be implemented to ameliorate and guarantee safety procedures

  13. Authenticity test in ceramics and archaeological figures by thermoluminescence

    International Nuclear Information System (INIS)

    Ramirez L, A.; Schaaf, P.; Filloy, L.

    1999-01-01

    At present exists quite a lot of false archaeological pieces which provokes doubts about the legitimacy of the pieces. In this work it is presented the Authenticity test by Thermoluminescence realized at the urn of the goddess 13 serpent of the zapotec culture of Oaxaca which is exposed in Mexico City. The original piece contains crystalline structures which present hardly the thermoluminescence phenomena by the presence of 238 U, 232 Th, and 40 K getting with this the form and intensity of the natural thermoluminescence curve of an archaeological piece which shows a Tl peak and allows to know so if it was made recently or not. (Author)

  14. Information for Stores Users

    CERN Multimedia

    Logistics Group

    2004-01-01

    As the FARNELL Catalogue CAPACITORS, RESISTORS and POTENTIOMETERS have now been integrated into the CERN Stores Catalogue (SCEM Groups 10 and 11) they can now be obtained via an EDH 'Material Request' like any other Stores item. N.B. The Farnell 'Order code' is one of the key-words that make it easier to find items in the Stores Catalogue. Logistics Group FI Department

  15. Thermoluminescence analysis for detection of irradiated food - luminescence characteristics of minerals for different types of radiation and radiation doses

    International Nuclear Information System (INIS)

    Soika, C.; Delincée, H.

    2000-01-01

    Federal Research Centre for Nutrition, Institute of Nutritional Physiology, Haid-und-Neu-Straße 9, 76131 Karlsruhe (Germany) Thermoluminescence analysis is used to detect radiation processing of foods which are contaminated with sand or dust. Silicate minerals are isolated, their radiation-induced luminescence is measured and compared to the thermoluminescence from a second measurement after exposure to a dexned radiation dose (normalization). In the present study, the mineral mixture *sand+ and its main components feldspar and quartz were investigated for their thermoluminescence behaviour using different types of radiation, in order to determine adequate radiation sources for the purpose of normalization. The material was irradiated with types of ionizing radiation commonly used for commercial food irradiation, i.e. accelerated electrons with beam energies of 5 MeV as well as 10 MeV, and 60 Co--rays. After thermoluminescence measurements, samples were re-irradiated using either accelerated electrons with beam energies of 2 MeV, 5 MeV or 10 MeV, or 60 Co--rays, 90 Sr--rays or ultraviolet rays (200}280 nm). Evaluation of the xrst and corresponding second glow curve revealed that their shapes depend on the type of minerals in the mixture. The second radiation treatment (normalization) is satisfactory when accelerated electrons (2, 5 and 10 MeV) as well as 60 Co--rays and 90 Sr--rays are employed. Normalization with ultraviolet rays, however, has only a limited range of use

  16. Thermoluminescence characterization of CVD diamond film exposed to UV and beta radiation

    International Nuclear Information System (INIS)

    Barboza-Flores, M.; Melendrez, R.; Gastelum, S.; Chernov, V.; Bernal, R.; Cruz-Vazquez, C.; Brown, F.; Pedroza-Montero, M.; Gan, B.; Ahn, J.; Zhang, Q.; Yoon, S.F.

    2003-01-01

    Thermoluminescence (TL) properties of diamond films grown by microwave and hot filament CVD techniques were studied. The main purpose of the present work was to characterize the thermoluminescence response of diamond films to ultraviolet and beta radiation. The thermoluminescence excitation spectrum exhibits maximum TL efficiency around 210-215 nm. All samples presented a glow curve composed of at least one TL peak and showed regions of linear as well as supralinear behavior as a function or irradiation dose. The linear dose dependence was found for up to sixteen minutes of monochromatic UV irradiation and 300 Gy for beta irradiated samples. The activation energy and the frequency factor were determined and found in the range of 0.33-1.7 eV and 5.44 x 10 2 -5.67 x 10 16 s -1 , respectively. The observed TL performance is reasonable appropriate to justify further investigation of diamond films as radiation dosimeters keeping in mind that diamond is an ideal TL dosemeter since it is tissue-equivalent and biological compatible. (copyright 2003 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  17. Thermoluminescence of laterites: applicability in dating

    International Nuclear Information System (INIS)

    Sankaran, A.V.; Nambi, K.S.V.; Sunta, C.M.

    1985-01-01

    The northward drift of the Indian subcontinent during the past geological periods brought it under the spell of humid tropical climate in post-mesozoic times which initiated chemical weathering processes (lateritization) of the ancient crustal rocks leading to neomineralization. In the present study, thermoluminescence (TL) of these 'later-formed minerals' has been used to date laterites from a number of localities in India. While the TL emission of most of the laterite samples was poor, three from Kerala, Tamil Nadu and Karnataka states, each derived from mineralogically dissimilar parent rock, yielded measurable TL and provided dates in the range of 2 to 3.6 x 10 5 yr. It is suggested that TL dating can be a promising tool for such samples, and especially those with low alpha activity (U, Th at sub-ppm levels). (author)

  18. Thermoluminescence of laterites: applicability in dating

    Energy Technology Data Exchange (ETDEWEB)

    Sankaran, A V; Nambi, K S.V.; Sunta, C M

    1985-01-01

    The northward drift of the Indian subcontinent during the past geological periods brought it under the spell of humid tropical climate in post-mesozoic times which initiated chemical weathering processes (lateritization) of the ancient crustal rocks leading to neomineralization. In the present study, thermoluminescence (TL) of these 'later-formed minerals' has been used to date laterites from a number of localities in India. While the TL emission of most of the laterite samples was poor, three from Kerala, Tamil Nadu and Karnataka states, each derived from mineralogically dissimilar parent rock, yielded measurable TL and provided dates in the range of 2 to 3.6 x 10/sup 5/ yr. It is suggested that TL dating can be a promising tool for such samples, and especially those with low alpha activity (U, Th at sub-ppm levels).

  19. Adjustment model of thermoluminescence experimental data

    International Nuclear Information System (INIS)

    Moreno y Moreno, A.; Moreno B, A.

    2002-01-01

    This model adjusts the experimental results for thermoluminescence according to the equation: I (T) = I (a i * exp (-1/b i * (T-C i )) where: a i , b i , c i are the i-Th peak adjusted to a gaussian curve. The adjustments of the curve can be operated manual or analytically using the macro function and the solver.xla complement installed previously in the computational system. In this work it is shown: 1. The information of experimental data from a LiF curve obtained from the Physics Institute of UNAM which the data adjustment model is operated in the macro type. 2. A LiF curve of four peaks obtained from Harshaw information simulated in Microsoft Excel, discussed in previous works, as a reference not in macro. (Author)

  20. Thermoluminescent dosimetry in veterinary diagnostic radiology

    International Nuclear Information System (INIS)

    Hernández-Ruiz, L.; Jimenez-Flores, Y.; Rivera-Montalvo, T.; Arias-Cisneros, L.; Méndez-Aguilar, R.E.; Uribe-Izquierdo, P.

    2012-01-01

    This paper presents the results of Environmental and Personnel Dosimetry made in a radiology area of a veterinary hospital. Dosimetry was realized using thermoluminescent (TL) materials. Environmental Dosimetry results show that areas closer to the X-ray equipment are safe. Personnel Dosimetry shows important measurements of daily workday in some persons near to the limit established by ICRP. TL results of radiation measurement suggest TLDs are good candidates as a dosimeter to radiation dosimetry in veterinary radiology. - Highlights: ► Personnel dosimetry in laboratory veterinary diagnostic was determined. ► Student workplaces are safe against radiation. ► Efficiency value of apron lead was determined. ► X-ray beams distribution into veterinarian laboratory was measured.

  1. Thermoluminescent dosimetric properties of Descalvado sand

    International Nuclear Information System (INIS)

    Teixeira, M.I.; Caldas, L.V.E.

    2006-01-01

    Sand samples proceeding from Descalvado, Sao Paulo, were studied with regard to their dosimetric properties using the thermoluminescence technique (TL) for high doses. These sand samples present steady physical and chemical characteristics to the end items, and they are used in the glass industry and for casting. The TL curves of the samples were obtained after an irradiation at the Gamma-Cell system ( 60 Co), of IPEN. The glow curves present two peaks at 80 C and 220 C approximately. Calibration curves were obtained for doses between 50 Gy and 5 kGy. The results indicate that the sand samples can be used for high-doses dosimetry in several areas of applications of ionizing radiation. (Author)

  2. Thermoluminescent dosimetry in fluoroscopy of pediatric patients

    International Nuclear Information System (INIS)

    Garcia V, E.; Azorin N, J.; Hidalgo T, S.; Dies S, P.

    2016-10-01

    The use of thermoluminescent dosimeters in the area of medical physics and especially in radiology is of paramount importance to guarantee the quality of a particular study, which for this reason the need to verify by means of measurements of peripheral dose in studies of esophagogastroduodenal series by fluoroscopy using TLD of LiF:Mg, Ti. For this the necessary measurements were carried out directly in patients of the Children s Hospital of Mexico Federico Gomez. Previously characterized the dosimeters were used the graphs of the linear equation to obtain the absorbed dose of each dosimeter and was found that the values of the absorbed dose in each patient changes for various reasons like the anatomy, thickness of the tissues, age and exposure time during the study and was verify that none of the studies performed on patients exceeded dose levels that could affect healthy organs. (Author)

  3. Environmental radiation studies relevant to thermoluminescence dating

    International Nuclear Information System (INIS)

    Murray, A.S.; Bowman, S.G.E.; Aitken, M.J.

    1980-01-01

    To determine the age of a potsherd by the thermoluminescence (TL) technique, one must have an accurate knowledge of the cosmic and environmental gamma dose rate in quartz. This is obtained by leaving a sensitive TL dosimeter buried as near as possible to the position from which the sherd was removed. The ratios of the response of a quartz-like dosimeter to those of CaF 2 and LiF have been measured. This experiment used a 1-m cube of concrete containing 3000 ppM of uranium and its daughters. Smaller, less active matrixes of 40 K and thorium and its daughters have also been constructed. A means of making direct dose-rate determinations when the site context remains but burial of a dosimeter is impractical was developed using a NaI(Tl) system. The equipment was field tested on approx. 40 Peruvian archaeological sites, and results are compared with CaF 2 measurements

  4. Thermoluminescent dosimetric properties of Descalvado sand

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, M.I.; Caldas, L.V.E

    2006-07-01

    Sand samples proceeding from Descalvado, Sao Paulo, were studied with regard to their dosimetric properties using the thermoluminescence technique (TL) for high doses. These sand samples present steady physical and chemical characteristics to the end items, and they are used in the glass industry and for casting. The TL curves of the samples were obtained after an irradiation at the Gamma-Cell system ({sup 60} Co), of IPEN. The glow curves present two peaks at 80 C and 220 C approximately. Calibration curves were obtained for doses between 50 Gy and 5 kGy. The results indicate that the sand samples can be used for high-doses dosimetry in several areas of applications of ionizing radiation. (Author)

  5. Thermoluminescence in alkali halides irradiated at 80K

    International Nuclear Information System (INIS)

    Jimenez de Castro, M.

    1978-01-01

    The thermoluminescence, the thermally stimulated currents and the thermal stability of the F centres induced in pure NaCl and KC1 crystals by X irradiation at 80K have been studied in detail, in the range between 80 and 300K. The thermoluminescent processes induced by illumination at 80K with F light in samples previously irradiated at room temperature has also been studied. It has been clearly observed the existence of thermoluminescent processes due to electrons and holes thermally released from traps, in which the F centres are not involved. The existence of hole-F centre recombination has not been observed. There are several thermoluminescent processes in both materials which are scribed to the recombination of F centres with mobile interstitial halogen atoms thermally released from traps, which are likely monovalent impurities in this temperature interval. The light emitting stage in these processes is originated by the formation of self trapped excitons. (Author) 66 refs

  6. Historical note: thermoluminescent dosimetry (LiF) 1950-51

    International Nuclear Information System (INIS)

    Heckelsberg, L.F.

    1980-01-01

    The early history of thermoluminescent dosimetry has not been adequately described and one of the first workers in this field takes this opportunity to record more fully the history of the period. (author)

  7. Natural dose level determination at Johor State with thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    Ahmad Termizi Ramli; Yusof Jasman

    1995-01-01

    This paperwork presented the results of using thermoluminescence dosimetry (TLD) method in measuring background dose level, which is done at State of Johor, South Malaysia. The problems faced also discussed

  8. Storage Telemetry of Radionuclide Tracers by Implantable Thermoluminescent Dosimeters

    DEFF Research Database (Denmark)

    Bojsen, J.; Møller, U.; Christensen, Poul

    1977-01-01

    A storage telemetrical method using thermoluminescent (TL) dosimeters for long-term measurements of incorporated radioactive substances in unrestrained rats has been developed. The system has been used in combination with radiotelemetrical registration of the circadian temperature rhythm. By sequ...

  9. A theoretical description of complex thermoluminescence curves: Pt. 1

    International Nuclear Information System (INIS)

    Kantorovich, L.N.; Fogel, G.M.; Gotlib, V.I.

    1988-01-01

    Thermoluminescence kinetics has been discussed within the framework of a band model assuming an extensive retrapping of charge carriers in comparison with their recombination. Assuming that a luminophor has one type of recombination centre and an arbitrary number of trapping centres we succeeded in analysing complex thermoluminescence curves with an arbitrary number of peaks. It has been shown for an elementary peak that its form almost coincides with the Randall-Wilkins curve, and its intensity is proportional to the square of the absorbed dose. The effect of both the processes of localised charge carriers accumulation (irradiation and isothermal decay) and their redistribution on trapping centres during the thermoluminescence process have been dealt with taking into account the form and intensity of the thermoluminescence peaks. (author)

  10. New laser technique revives old ideas for thermoluminescence neutron dosimetry

    International Nuclear Information System (INIS)

    Braeunlich, P.; Brown, M.; Gasiot, J.; Fillard, J.P.

    1982-01-01

    Laser heating is discussed as a means to evaluate thermoluminescence dosimeters in neutron dosimetry. Direct energy coupling from the photon beam to the phonons of the TL material permits heating of thin layers with rates of temperature increase exceeding 10 4 Ks - 1 . Rapid TLD evaluation will allow the design of dosimetry badges containing a number of different small thin film TLD elements in various orientations and behind appropriate filters, hydrogenous radiators, etc. Desired redundance is readily possible by using back-up TLDs for every specific task. Reading occurs with a scanning laser beam rather than by mechanically manipulating the TLD toward a fixed heat source. Improvements in the signal-to-noise ratio of up to a factor of 1000 are readily obtained. Thus, sensitive thin-film TLDs can be designed with negligible self-shielding for thermal neutrons in albedo applications and with known, nearly energy dependent cavity correction factors for dosimetry in mixed n-#betta# fields. Due to the greatly increased sensitivity possible with fast laser heating, significant advances are expected in the fast neutron dosimetry techniques which are based on hydrogeneous proton radiators or LET-dependent slow peak formation

  11. Entrance surface dose measurements in mammography using thermoluminescence technique

    International Nuclear Information System (INIS)

    Rivera, T.; Vega C, H.R.; Manzanares A, E; Azorin, J.; Gonzalez, P.R.

    2007-01-01

    Full text: Of the various techniques that can be used for personnel dosimetry, thermoluminescence dosimetry (TLD) has emerged as a superior technique due to its manifold advantages over other methods of dose estimation. Various phosphors have been therefore investigated regarding their suitability for dosimetry. In this paper, a dosimetry system based on thermally stimulated luminescence (TSL) from zirconium oxide phosphors embedded in polytetrafluorethylene (ZrO 2 +PTFE) was developed for entrance surface doses (ES) measurements in mammography. Small ZrO 2 pellets of 5 mm in diameter and 0.8 mm in thickness were used. The reproducibility of measurements and linearity of ZrO 2 were also studied. The results were compared with those obtained from LiF:Mg,Cu,P usually used for the determination of absorbed dose in mammography. Measurements both per unit air kerma and In vivo were performed using a mammography unit model DMR (General Electric). The results showed that ZrO 2 TLDs can be used for the same X-ray dosimetry applications as LiF:Mg,Cu,P, with each type having the disadvantage of a response dependent on energy, particularly at low energies. These results indicate a considerable potential for use in routine control and In vivo ES measurements in mammography. (Author)

  12. Nudging consumer behaviour in retail stores

    DEFF Research Database (Denmark)

    Adam, Abdulfatah

    2016-01-01

    -effectiveness of alternative interventions in retail store settings. In cooperation with a supermarket chain in Denmark, we manipulated food locations inside the store so that relatively low energy dense products were placed favorable shelf locations. The underlying theory for the experiment was the behavioral approach (so...

  13. Predicting Commissary Store Success

    Science.gov (United States)

    2014-12-01

    stores or if it is possible to predict that success. Multiple studies of private commercial grocery consumer preferences , habits and demographics have...appropriate number of competitors due to the nature of international cultures and consumer preferences . 2. Missing Data Four of the remaining stores

  14. Storing up trouble

    International Nuclear Information System (INIS)

    Townsley, M.

    1992-01-01

    Scottish Nuclear have applied for permission to build a temporary ground-level dry store for spent fuel at Torness. However, Nirex's failure to find a suitable site for a long-term repository could mean that the Torness store will be less temporary than planned. (author)

  15. Information for stores users

    CERN Multimedia

    Logistics Group - FI Department

    2005-01-01

    The Farnell catalogue can now be accessed from the Material Request form on EDH in addition to the CERN Stores catalogue. Users can order Farnell equipment as well as standard Stores equipment at the same time using a single document, the EDH Materials Request form. The Materials Request form offers users items from both the internal 'Stores' catalogue and the external 'Farnell' catalogue, all of which may be ordered on the same form. The system automatically forwards orders for standard Stores equipment to the CERN Stores and those for Farnell equipment to Farnell. The delivery time is 48 hours in both cases. Requests for materials are routed for approval in accordance with the standard EDH routing procedures. Logistics Group FI Department

  16. Dosimetric Characteristics of a LKB:Cu,Mg Solid Thermoluminescence Detector

    International Nuclear Information System (INIS)

    Alajerami Yasser Saleh Mustafa; Hashim Suhairul; Ramli Ahmad Termizi; Saleh Muneer Aziz; Kadir Ahmad Bazlie Bin Abdul; Saripan, Mohd. Iqbal

    2013-01-01

    We present the main thermoluminescence characteristics of a newly borate glass dosimeter modified with lithium and potassium carbonate (LKB) and co-doped with CuO and MgO. An enhancement of about three times has been shown with the increment of 0.1mol% MgO as a co-dopant impurity. The effects of dose linearity, storage capacity, effective atomic number and energy dose response are studied. The proposed dosimeter shows a simple glow curve, good linearity up to 10 3 Gy, close effective atomic number and photon energy independence. The current results suggest using the proposed dosimeter in different dosimetric applications

  17. Evaluation of thermoluminescent BeO samples in standard radiotherapy beams; Avaliacao de amostras termoluminescentes de BeO em feixes padroes de radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Groppo, Daniela P.; Silva, Jonas O.; Caldas, Linda V.E., E-mail: daniela.piai.groppo@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2012-08-15

    Beryllium oxide thermoluminescent samples were evaluated in standard radiotherapy beams of low energy. Results for response reproducibility, dose-response curve and energy dependence were obtained. The lower detection limit was determined. The pellets of BeO showed their usefulness for beam dosimetry. (author)

  18. Thermoluminescence studies of the thermal and radiation histories of chondritic meteorites

    International Nuclear Information System (INIS)

    Melcher, C.L.

    1980-01-01

    The thermoluminescence properties of chondritic meteorites are investigated to understand the ways in which the stored TL reflects the thermal and radiation histories of these objects. Differences in TL levels measured in recent falls are attributed to small differences in orbital temperatures. In addition, a correlation between TL level and terrestrial age is observed in meteorites of known terrestrial age. The thermoluminescence in chondrites is produced primarily by ionization from galactic cosmic rays with a much smaller contribution from the decay of natural radionuclides (U, Th, K, Rb). The production of most of the TL occurs after the break up of the large parent bodies into meter-size objects which are thus exposed to the ionizing effects of the cosmic rays. Measurements indicate that the low temperature TL represents a dynamic equilibrium between build up from ionizing radiation and thermal draining. The high temperature TL is near saturation. The terrestrial ages currently of greatest interest are those of the recently discovered meteorites in Antarctica. TL measurements were made on 11 of these meteorites and compared with the activities of 14 C, 26 Al, and 36 Cl measured by other workers in terrestrial age studies. A good correlation was found between the TL levels and the activities of cosmogenic radionuclides in these meteorites. Since the TL measurements can be made more rapidly and require much smaller samples (approx. 10 mg) than the radionuclide measurements, TL is most useful as a screening process to select potentially interesting samples for further study by more precise techniques

  19. Thermoluminescence, luminescence optically stimulated and creation of defects in alkaline halogenides contaminated with Europium

    International Nuclear Information System (INIS)

    Barboza F, M.

    1999-01-01

    The alkaline halogenides have been subject matter of investigations related with the search of sensor materials for X-ray bidimensional images or optical memories. The understanding of the damage formation processes generated by ionizing and non-ionizing radiations is important for the correct design of devices that working as detectors and dosemeters of both type of radiations. In this work we present the investigation results related with the defects produced by the ionizing radiation type X and ultraviolet light in the range of 200-360 nm in crystals of KCl: Eu 2+ and KBr:Eu 2+ . It is examined the thermoluminescence and luminescence spectra with the purpose of identifying the exciton processes, owing to the excitation of the halogenide ions in which the primary defects correspond to the F and H centers. It has been found that the 400-600 nm emission is associated with the luminescence type that in his turn can be associated with autotrapped excitons perturbed by the impurity. On the other hand, it is examined the emission spectra of the luminescence optically stimulated in crystals of KBr: Eu 2+ and KCl: Eu 2+ finding too that such materials would be used as optical memories susceptible of to store information, and through of photostimulation to read this. It was determined that the F centers participate in the luminescence optically stimulated in these crystals, as well as too in the recombination processes responsible by the thermoluminescent emission. (Author)

  20. Information for stores users

    CERN Multimedia

    2007-01-01

    From next week, the SFS UNIMARKET (tooling) catalogue will be accessible using the Material Request form on EDH in addition to the CERN Stores catalogue and those of existing suppliers. Users will now be able to place orders from the SFS catalogue using the Material Request form on EDH. Note: The system automatically forwards orders for standard Stores equipment and those for SFS equipment, placed using the same Material Request form, to the CERN Stores and SFS respectively. In both cases, the maximum delivery time will be 48 hours. Requests for equipment will be routed for approval in accordance with standard EDH routing procedures. Logistics Group FI Department

  1. INFORMATION FOR STORES USERS

    CERN Multimedia

    2007-01-01

    From next week, the SFS UNIMARKET (tooling) catalogue will be accessible using the Material Request form on EDH in addition to the CERN Stores catalogue and those of existing suppliers. Users will now be able to place orders from the SFS catalogue using the Material Request form on EDH. Note: The system automatically forwards orders for standard Stores equipment and those for SFS equipment, placed using the same Material Request form, to the CERN Stores and SFS respectively. In both cases, the maximum delivery time will be 48 hours. Requests for equipment will be routed for approval in accordance with standard EDH routing procedures. Logistics Group FI Department

  2. Information for stores users

    CERN Multimedia

    2006-01-01

    The Radiospares Catalogue is now accessible from the Material Request page on EDH in the same way as the CERN Stores Catalogue. This means that users can order Radiospares equipment by completing an EDH Materials Request form. N.B.: The system will automatically forward orders for standard Stores equipment to the CERN Stores and those for Radiospares equipment to Radiospares. In both cases the delivery time will be a maximum of 48 hours. Requests for materials will be routed for approval in accordance with the standard EDH routing procedures. Logistics Group FI Department

  3. INFORMATION FOR STORES USERS

    CERN Multimedia

    SPL Division

    1999-01-01

    You can now make Material Request from CERN Stores over the WEB :CERN Home/Administrative Tools/EDH/Material Requestor https://edh.cern.ch/Document/MAGVia the Stores Catalogue : CERN Home/Administrative Tools/Stores Catalogueor http://edhcat.cern.ch/In both cases, you need to enter your EDH login and password.For more details, you can consult the Quick Reference Guide on :http://edh.cern.ch/doc/quickrefguides.htmlor obtain a printed version from AIS Support at tel: 79933or e-mail to: ais.support@cern.chSPL DivisionLogistics Group

  4. Information for stores users

    CERN Multimedia

    2006-01-01

    The Bossard catalogue is now accessible alongside the CERN Stores catalogue from the Material Request form on EDH. Users will thus be able to order Bossard equipment using the EDH Materials Request form. As a reminder, the system automatically forwards orders for standard Stores equipment to the CERN Stores and those for Bossard equipment to Bossard. In both cases the delivery time will be a maximum of 48 hours. Requests for materials will be routed for approval in accordance with the standard EDH routing procedures. Some items will remain available from the emergency desk in the event of urgent requests. These items will be visible in the Stores catalogue even if they cannot be purchased via the EDH material request form. Logistics Group FI Department

  5. Thermoluminescent analysis of archaeological ceramic from Teotenango, Mexico

    International Nuclear Information System (INIS)

    Dominguez R, R.; Mondragon, M.; Villa S, G.; Gonzalez M, P.R.; Mendoza A, D.

    2006-01-01

    Of all the kind of artifacts which may be found at archaeological sites, ceramics are surely among the most important. A ceramic material is highly durable, and virtually unchanged after hundred of years from its date of manufacture. Because of this, a ceramic will always be an important object for serious studies to determine which culture produced it, to date cultures, reconstruct economic patterns and social organization, and establish routes of trade or simply to classify the different types of ceramics. The aim of this paper was to perform a thermoluminescent analysis of archaeological ceramic samples belonging to Teotenango, Mexico. The analysis is complemented with a physicochemical characterization by Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectroscopy (EDS), X-Ray Diffraction (XRD). TL analysis shows some differences when the samples are exposed to ionizing radiation field, while SEM analysis shows a porous and granular structure in all samples, EDS analysis shows oxygen (O), aluminum (Al), silicon (Si), iron (Fe), sodium (Na), phosphorus (P), potassium (K) and calcium (Ca) in significant amounts. These results allow establishing differences among ceramic samples belonging to the same place. (Author)

  6. Thermoluminescent analysis of archaeological ceramic from Teotenango, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Dominguez R, R. [Centro INAH Estado de Mexico, Morelos Ote. 502, Col. San Sebastian, 50090 Toluca, Estado de Mexico (Mexico); Mondragon, M. [Museo Roman Pina Chan, Teotenango 1024 (Mexico); Villa S, G.; Gonzalez M, P.R.; Mendoza A, D. [ININ, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2006-07-01

    Of all the kind of artifacts which may be found at archaeological sites, ceramics are surely among the most important. A ceramic material is highly durable, and virtually unchanged after hundred of years from its date of manufacture. Because of this, a ceramic will always be an important object for serious studies to determine which culture produced it, to date cultures, reconstruct economic patterns and social organization, and establish routes of trade or simply to classify the different types of ceramics. The aim of this paper was to perform a thermoluminescent analysis of archaeological ceramic samples belonging to Teotenango, Mexico. The analysis is complemented with a physicochemical characterization by Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectroscopy (EDS), X-Ray Diffraction (XRD). TL analysis shows some differences when the samples are exposed to ionizing radiation field, while SEM analysis shows a porous and granular structure in all samples, EDS analysis shows oxygen (O), aluminum (Al), silicon (Si), iron (Fe), sodium (Na), phosphorus (P), potassium (K) and calcium (Ca) in significant amounts. These results allow establishing differences among ceramic samples belonging to the same place. (Author)

  7. Practical use of lithium borate in thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Chavaudra, J.; Nguyen, J.; Marinello, G.; Brule, A.M.

    1976-01-01

    The functional principles of thermoluminescent dosimeters are recalled: heating, apparatus for measuring the emitted light, circulation of nitrogen, reference source. The essential role played by the circulation of nitrogen over the dosimeters which equilibrates the temperature of the photomultiplier, reduces the emission of unwanted light, prevents the combustion of dust or other possible impurities and finally improves the accuracy of the measurements even for high doses, is underlined. Lithium borate is taken as an example and a simple method for finding the optimum working conditions for the heating apparatus of the planchette in the most simple T.L.D. readers and in those where the heating apparatus of the planchette has a pre-heating phase is proposed. The dosimetric properties of lithium borate incorporated in thin teflon discs (type DLB. 0.13 and 0.4) are studied. This shows itself to be very interesting for certain uses because it is a solid dosimeter which does not require annealing between two measurements. The accuracy of the measurements obtained with this material, the stability of the response relative to the delay between radiation and reading (fading), the response relative to the absorbed dose plus the nature and the energy of the rays, are presented with the usual reservations made for this type of dosimetry [fr

  8. Thermoluminescence characterization of the irradiated minerals extracted from nopal

    Science.gov (United States)

    Cruz-Zaragoza, E.; Furetta, C.; Kitis, G.; Gomez, B. T.; Polymeris, G. S.; Tsirliganis, N.; Loukou, Z.

    2006-05-01

    The mineral fraction from dehydrated nopal leaves (Opuntia ficus indica ) belonging to the Cactaceae family was extracted and selected by sizes of 10 and 74 mu m and exposed to 60 Co gamma radiation at different doses in the range 70 Gy-20 kGy. The glow-curves from these polyminerals show a thermoluminescence (TL) band with one very intense peak at a temperature around 150 degrees C and a second one emerging in the high temperature region, moving in a large zone of temperature values according to the preparation used and the level of irradiation. The XRD analysis shows a composition of both biominerals as whewellite and weddellite and a mineral fraction as anorthoclase and quartz. The main TL characteristics of the polymineral content of the nopal was analyzed, i.e . the TL response at different doses and fading during storage at room temperature. The activation energy of the traps responsible for the TL emission was also investigated and a possible continuous distribution of traps is discussed. A review of the scientific literature shows that this is the first time that a TL study on nopal ionized by irradiation has been carried out.

  9. Thermoluminescence studies of natural and doped calcium fluoride phosphors

    International Nuclear Information System (INIS)

    El Kolaly, M.A.

    1977-01-01

    The various aspects of thermoluminescence (TL) of calcium fluoride phosphors obtained both from natural and laboratory-grown CaF 2 crystals have been investigated in the temperature range from room temperature to 750 deg C. Dopants used in these studies were Mn, Y and lanthanide series rare earths. The aspects which have been investigated are : (1) effect of single and double doping on TL glow curves and TL emission spectra after gamma irradiation, (2) TL traps : their kinetics including evaluation of the activation energy using different techniques, their decay kinetics and their behaviour under partially filled conditions, and (3) effect of temperature on emission of intensity of X-ray induced luminescence and TL. During the course of these investigations, a new glow peak was observed at 650 deg C in natural CaF 2 . It was found that this peak could also be produced in synthetic CaF 2 doped with (Y + Sm). A new model for the TL trap has also been proposed. (M.G.B.)

  10. γ radiation thermoluminescence performance of HFCVD diamond films

    International Nuclear Information System (INIS)

    Gastelum, S.; Cruz-Zaragoza, E.; Melendrez, R.; Chernov, V.; Barboza-Flores, M.

    2006-01-01

    Polycrystalline chemically vapor deposited (CVD) diamond films have been proposed as detectors and dosimeters of ionizing radiation with prospective applications in high-energy photon dosimetry applications. We present a comparison study on the thermoluminescence (TL) properties of two diamond film samples grown by the hot filament CVD method having thickness of 180 and 500 μm and exposed to γ radiation in the 1-300 Gy dose range. The 180 μm thick sample deposited on silicon substrate displayed a TL glow curve peaked at 145 deg. C. The 500 μm, which was a free standing sample, exhibited higher intensity and a well defined first order kinetics TL glow peak around 289 deg. C. Both diamond samples showed a linear dose behavior in the 1-50 Gy range and sublinear behavior for higher doses. The 180 and 500 μm samples presented about 80% and 30% TL losses in a 24 h period, respectively, with both samples showing excellent TL reproducibility. The results indicate that the 500 μm CVD diamond film exhibited a good TL behavior adequate for γ radiation dosimetry

  11. Thermal quenching of thermoluminescence in quartz samples of various origin

    International Nuclear Information System (INIS)

    Subedi, B.; Oniya, E.; Polymeris, G.S.; Afouxenidis, D.; Tsirliganis, N.C.; Kitis, G.

    2011-01-01

    The effect of thermal quenching stands among the most important properties in the thermoluminescence (TL) of quartz on which many applications of TL are based. Since the quartz samples used in various applications are all of different origin it is useful to investigate whether the values of the thermal quenching parameters, i.e. the activation energy for thermal quenching W and a parameter C which describes the ratio of non-radiative to radiative luminescence transitions, evaluated mainly in specific quartz samples can be extrapolated to quartz samples of unknown origin as well as to quartz samples which are annealed at high temperatures. In the present work the TL glow curve of a series of un-annealed and annealed natural and synthetic quartz samples were studied as a function of the heating rate between 0.25 K/s and 16 K/s. Using an indirect fitting method it was found that the thermal quenching parameters W and C in most of the quartz samples are very similar to the values accepted in the literature. Furthermore, in some cases the thermal quenching parameters W and C are not the same for all TL glow-peaks in the same glow-curve. Finally, the strong external treatment of annealing the quartz samples at very high temperature can also influence at least one of the thermal quenching parameters.

  12. Provenance Store Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Paulson, Patrick R.; Gibson, Tara D.; Schuchardt, Karen L.; Stephan, Eric G.

    2008-03-01

    Requirements for the provenance store and access API are developed. Existing RDF stores and APIs are evaluated against the requirements and performance benchmarks. The team’s conclusion is to use MySQL as a database backend, with a possible move to Oracle in the near-term future. Both Jena and Sesame’s APIs will be supported, but new code will use the Jena API

  13. Energy dependence of the supralinearity (f(D)max) of peaks 7 and 8 in the high temperature thermoluminescence of LiF:Mg,Ti (TLD-100) : Interpretation using the Unified Interaction Model

    International Nuclear Information System (INIS)

    Datz, H.; Horowitz, Y.S.; Epstein, L.; Oster, L.; Livingstone, J.; Horowitz, A.; Kol, M.; Margaliot, M.

    2011-01-01

    It is demonstrated that the supralinearity of the dose response of glow peaks 7, 8 in the glow curve of LiF:Mg,Ti (TLD-100) are very strongly dependent on photon/electron energy. Previously published data on f(D) max at photon energies of 1.25 MeV, 100 keV and 8.1 keV effective energy coupled with new data at ∼ 540 keV using 90 Sr/ 90 Y beta rays reveals that the maximum supralinearity f(D) max decreases from values of ∼200 and ∼30 at 1.25 MeV, through intermediate values at 540 keV and 100 keV, to values of ∼ 30 and ∼3 at 8.1 keV effective energy. The normalized dose response f(D) for all energies is modeled using the Unified Interaction Model and the dependence of f(D) max on energy is interpreted as arising from strong dependence of the relative intensity of localized recombination on particle energy (ionization density).

  14. Thermoluminescent characteristics of synthetic hydroxyapatite (SHAp)

    International Nuclear Information System (INIS)

    Alvarez, R.; Rivera, T.; Guzman, J.; Piña-Barba, M.C.; Azorin, J.

    2014-01-01

    This paper presents the experimental results of the thermoluminescent (TL) characteristics of synthetic hydroxyapatite (SHAp) obtained by the sol–gel method. For preparation of the SHAp powders, phosphorus pentoxide (P 2 O 5 ) and calcium nitrate tetrahydrated (Ca(NO 3 ) 2 –4H 2 O) were used. The powders obtained were submitted at different temperatures. The structural and morphological characterization were carried out using X-ray diffraction (XRD) and scanning electron microscopy techniques. TL glow curve exhibited two peaks centered at around 200 °C and 300 °C. TL response of SHAp as a function of gamma absorbed dose was linear over a wide dose range. Fading of the storage information in the samples irradiated was also studied. The experimental results show that the synthetic hydroxyapatite obtained by the sol–gel method may have used in gamma radiation dosimetry applications. - highlights: • Dosimetric characteristics of SHAp under gamma irradiation effect were analyzed • SHAp powders were obtained by Sol–Gel method • Fading anomalous of HAp was performed showing 15% during 90 days • SHAp showed good dosimetric characteristics. • Dosimetric characteristics of SHAp have not been reported yet in the literature before this paper

  15. Thermoluminescence of zircon: a kinetic model

    CERN Document Server

    Turkin, A A; Vainshtein, D I; Hartog, H W D

    2003-01-01

    The mineral zircon, ZrSiO sub 4 , belongs to a class of promising materials for geochronometry by means of thermoluminescence (TL) dating. The development of a reliable and reproducible method for TL dating with zircon requires detailed knowledge of the processes taking place during exposure to ionizing radiation, long-term storage, annealing at moderate temperatures and heating at a constant rate (TL measurements). To understand these processes one needs a kinetic model of TL. This paper is devoted to the construction of such a model. The goal is to study the qualitative behaviour of the system and to determine the parameters and processes controlling TL phenomena of zircon. The model considers the following processes: (i) Filling of electron and hole traps at the excitation stage as a function of the dose rate and the dose for both (low dose rate) natural and (high dose rate) laboratory irradiation. (ii) Time dependence of TL fading in samples irradiated under laboratory conditions. (iii) Short time anneali...

  16. Thermoluminescence analysis of irradiated oyster shells

    International Nuclear Information System (INIS)

    Cruz-Zaragoza, E.; Marcazzó, J.; Della Monaca, S.; Boniglia, C.; Gargiulo, R.; Bortolin, E.

    2012-01-01

    This paper reports the thermoluminescence (TL) analysis performed on the oyster shells powder. TL response of 60 Co gamma-rays irradiated samples were studied in the range from 80 Gy to 8 kGy doses. TL signal of irradiated shell powder was higher as compared to the unirradiated control samples, which allowed to identify the irradiated oysters. Results show that the oyster shells have good TL properties and can be useful for the identification of irradiated seafood as well as for the evaluation of the treatment dose. - Highlights: ► TL properties of irradiated oyster shell powder were studied. ► The SEM analysis shows that several elements are present in oyster shell powder. ► Calcite is the main component in the samples and β-calcite is also present. ► Following the European Standard EN 1788, the irradiated oyster can be identified. ► Determination of absorbed dose is possible by performing a preheat treatment.

  17. Thermoluminescent and impedimetric studies on irradiated foodstuffs

    International Nuclear Information System (INIS)

    Mamoon, A.M.

    2000-01-01

    Several brands of different spices and milk powders were irradiated with relatively high doses of gamma radiation. Glow curves were produced upon heating these irradiated foodstuffs only. Study of the obtained spices glow curves revealed that the magnitude of these curves depends upon the dose received while the shape of the curves remains generally the same for the different doses and for the different spices. Previous studies had shown that the obtained thermoluminescence (TL) is due to dust particles carried by the spices. The TL studies show, furthermore, that different brands of the same spice are apparently contaminated with different amounts of dust or soil. The obtained TL from irradiated milk powders is apparently due to its mineral content. Different milk powders gave TL curves of different magnitudes for the same dose depending upon the milk brand. Impedimetric studies carried out irradiated potatoes show changes in impedance amplitude and phase angle. The results support earlier work on the use of TL to differentiate between irradiated and control foodstuffs, to assess the extent of spices contamination with soil-which perhaps reflects hygienic care-and that impedimetric measurements can distinguish irradiated from control potatoes

  18. Detection of irradiated spices by thermoluminescence analysis

    International Nuclear Information System (INIS)

    Hammerton, K.M.; Banos, C.

    1996-01-01

    Spices are used extensively in prepared foods. The high levels of contamination of many spices with microorganisms poses a problem for the food industry. Irradiation treatment is the most effective means of reducing the microbial load to safe levels. Although the process is currently subject to a moratorium in Australia, it is used in several countries for the decontamination of spices. Methods for detecting irradiation treatment of spices are necessary to enforce compliance with labelling requirements or with a prohibition on the sale of irradiated foods. Thermoluminescence (TL) analysis of spice samples has been shown to be an applicable method for the detection of all irradiated spices. It was established that the TL response originates from the adhering mineral dust in the sample. Definitive identification of many irradiated spices requires the separation of a mineral extract from the organic fraction of the spice sample. This separation can be achieved by using density centrifugation with a heavy liquid, sodium polytungstate. Clear discrimination between untreated and irradiated spice samples has been obtained by re-irradiation of the mineral extract after the first TL analysis with an absorbed dose of about 1 kGy (normalisation). The ratio of the first to second TL response was about one for irradiated samples and well below one for untreated samples. These methods have been investigated with a range of spices to establish the most suitable method for routine control purposes. (author)

  19. Evaluation of environmental monitoring thermoluminescent dosimeter locations

    International Nuclear Information System (INIS)

    Kinnison, R.

    1992-12-01

    Geostatistics, particularly kriging, has been used to assess the adequacy of the existing NTS thermoluminescent dosimeter network for determination of environmental exposure levels. (Kriging is a linear estimation method that results in contour plots of both the pattern of the estimated gamma radiation over the area of measurements and also of the standard deviations of the estimated exposure levels.) Even though the network was not designed as an environmental monitoring network, ft adequately serves this function in the region of Pahute and Rainier Mesas.. The Yucca Flat network is adequate only if a reasonable definition of environmental exposure levels is required; R is not adequate for environmental monitoring in Yucca Flat if a coefficient of variation of 10 percent or less is chosen as the criterion for network design. A revision of the Yucca Flat network design should be based on a square grid pattern with nodes 5000 feet (about one mile) apart, if a 10 percent coefficient of variation criterion is adopted. There were insufficient data for southern and western sections of the NTS to perform the geostatistical analysis. A very significant finding was that a single network design cannot be used for the entire NTS, because different areas have different variograms. Before any design can be finalized, the NTS management must specify the exposure unit area and coefficient of variation that are to be used as design criteria

  20. Competition between excitation and bleaching of thermoluminescence

    International Nuclear Information System (INIS)

    Chen, R.; Hornyak, W.F.

    1990-01-01

    The bleaching of thermoluminescence (TL) yield to a residual value by light is explained, at least in some cases, to be due to an equilibrium between excitation and de-excitation by the illuminating light. Kinetic differential equations are given governing the process for the simple case of a single trapping state for electrons and a single variety of hole recombination centre. The equations are solved numerically for chosen sets of the relevant parameters starting either from empty traps and centres or from highly populated ones. In agreement with experimental results, the numerical computation predicts that after a long enough illumination the process of filling of the traps converges to the same equilibrium value as that produced by bleaching. It is also found that the equilibrium value is independent of the intensity, though, of course, this is approached faster with more intense light. The computed dependencies of the filling of trapping states as a function of illumination time are shown. The final equilibrium value for the filling of trapping states can also be evaluated analytically for any set of given parameters; these compare very favourably with the calculated results. The change of the results with the variation of the relevant parameters is discussed. (author)

  1. Thermoluminescence of calcium-based phosphors

    International Nuclear Information System (INIS)

    Sunta, C.M.

    1985-01-01

    The paper reviews the thermoluminescence (TL) properties of calcium fluoride, calcium sulphate and calcium carbonate phosphors. In the case of the calcium fluoride mineral phosphor the main emitter of TL is the cerium impurity. Based on the TL emission spectra, two types of Ce 3+ centres can be easily distinguished; those associated with O 2- compensating ion and those which have either no local compensators or are associated with F - interstitial ions at the adjacent vacant body centre position. The spectra undergo remarkable changes at high doses. Such changes are associated with the probabilities of charge trapping at different types of traps and also with the probabilities of recombination at different types of luminescent centres. Some of the traps and recombination centres are spatially associated while others are distributed randomly. In calcium carbonate mineral, Mn 2+ is invariably the emitting impurity. Mn 2+ can be used as an efficient dopant for TL emission in all the three calcium based TL phosphors. A co-dopant like Ce 3+ intensifies the luminescence yield from Mn 2+ . Models of different types of electron and hole trapping centres are given. (author)

  2. Thermoluminescence dating of Brazilian indigenous ceramics

    International Nuclear Information System (INIS)

    Farias, T. M. B.; Gennari, R. F.; Etchevarne, C.; Watanabe, S.

    2009-01-01

    Two indigenous ceramics fragments, one from Lagoa Queimada (LQ) and another from Barra dos Negros (BN), both sites located on Bahia state (Brazil), were dated by thermoluminescence (TL) method. Each fragment was physically prepared and divided into two fractions, one was used for TL measurement and the other for annual dose determination. The TL fraction was chemically treated, divided in sub samples and irradiated with several doses. The plot extrapolation from TL intensities as function of radiation dose enabled the determination of the accumulated dose (D ac ), 3.99 Gy and 1.88 Gy for LQ and BN, respectively. The annual dose was obtained through the uranium, thorium and potassium determination by ICP-MS. The annual doses (D an) obtained were 2.86 and 2.26 mGy/year. The estimated ages were ∼1375 and 709 y for BN and LQ ceramics, respectively. The ages agreed with the archaeologists' estimation for the Aratu and Tupi tradition periods, respectively. (authors)

  3. The Nord interim store

    International Nuclear Information System (INIS)

    Leushacke, D.F.; Rittscher, D.

    1996-01-01

    In line with the decision taken in 1990 to shut down and decommission the Greifswald and Rheinsberg Nuclear Power Stations, the waste management concept of the Energiewerke Nord is based on direct and complete decommissioning of the six shut down reactor units within the next fifteen years. One key element of this concept is the construction and use of the Zwischenlager Nord (Nord Interim Store, ZLN) for holding the existing nuclear fuels and for interim and decay storage of the radioactive materials arising in decommissioning and demolition. The owner and operator of the store is Energiewerke Nord GmbH. The interim store has the functions of a processing and Energiewerke Nord GmbH. The interim store has the functions of a processing and treatment station and buffer store for the flows of residues arising. As a radioactive waste management station, it accommodates nuclear fuels, radioactive waste or residues which are not treated any further. It is used as a buffer store to allow the materials accumulating in disassembly to be stored temporarily before or after treatment in order to ensure continuous loading of the treatment plants. When operated as a processing station, the ZLN is able to handle nearly all types of radioactive waste and residues arising, except for nuclear fuels. These installations allow the treatment of radioactive residues to be separated from the demolition work both physically and in time. The possibilities of interium storage and buffer storage of untreated waste and waste packages make for high flexibility in logistics and waste management strategy. (orig.) [de

  4. Obtention of a thermoluminescent material for dosimetry of ionizing radiation; Obtencion de un material termoluminiscente para dosimetria de la radiacion ionizante

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez M, P R

    1990-07-01

    The thermoluminescent dosemeters are small crystals which suffer changes in their structure by the radiation effect, being displaced the electrons toward higher energy levels. On heating the previously irradiated crystals, the electrons come back to their base state emitting light photons. The light quantity emitted is proportional to the received radiation dose. The light quantity emitted is proportional to the received radiation dose. The lithium fluoride is one of the thermoluminescent materials considered as tissue equivalents by having a low effective atomic number (Z{sub ef}). At present, the more used commercial product used of this type is the TLD-100*. In this work the obtained results in the preparation of the lithium fluoride thermoluminescent material are presented. This is activated with magnesium (Mg) and titanium (Ti), which we have labelled as: LiF: Mg, Ti. The results from the tests performed for verifying his thermoluminescent properties are presented too, as powder form as in pellets form. These tests were performed in simultaneous form with TLD-100 samples, which is considered as reference. The LiF: Mg, Ti thermoluminescent material manufactured in the ININ presents similar dosimetric characteristics to those ones of the TLD-100. Therefore being able to replace the imported dosemeters. * (TLD-100 is a commercial trademark registered by Harshaw/Filtrol (US) for LiF: Mg, Ti Tl dosemeters) (Author)

  5. In vivo dosimetry thermoluminescence dosimeters during brachytherapy with a 370 GBq 192Ir source

    International Nuclear Information System (INIS)

    Cuepers, S.; Piessens, M.; Verbeke, L.; Roelstraete, A.

    1995-01-01

    When using LiF thermoluminescence dosimeters in brachytherapy, we have to take into account the properties of a high dose rate 192 Ir source (energy spectrum ranging form 9 to 885 keV, steep dose gradient in the vicinity of the source) and these of the dosimeters themselves (supralinearity, reproducibility, size). All these characteristics combine into a set of correction factors which have been determined during in phantom measurements. These results have then been used to measure the dose delivered to organs at risk (e.g. rectum, bladder, etc.) during high dose rate brachytherapy with a 370 GBq 192 Ir source for patients with gynaecological tumors

  6. In vivo dosimetry thermoluminescence dosimeters during brachytherapy with a 370 GBq {sup 192}Ir source

    Energy Technology Data Exchange (ETDEWEB)

    Cuepers, S; Piessens, M; Verbeke, L; Roelstraete, A [Onze-Lieve-Vrouw Hospitaal, Aalst (Belgium). Dept. of Radiotherapy and Oncology

    1995-12-01

    When using LiF thermoluminescence dosimeters in brachytherapy, we have to take into account the properties of a high dose rate {sup 192}Ir source (energy spectrum ranging form 9 to 885 keV, steep dose gradient in the vicinity of the source) and these of the dosimeters themselves (supralinearity, reproducibility, size). All these characteristics combine into a set of correction factors which have been determined during in phantom measurements. These results have then been used to measure the dose delivered to organs at risk (e.g. rectum, bladder, etc.) during high dose rate brachytherapy with a 370 GBq {sup 192}Ir source for patients with gynaecological tumors.

  7. Thermoluminescence studies of Nd doped Bi_4Ge_3O_1_2 crystals irradiated by UV and beta sources

    International Nuclear Information System (INIS)

    Karabulut, Y.; Canimoglu, A.; Ekdal, E.; Ayvacikli, M.; Can, N.; Karali, T.

    2016-01-01

    Thermoluminescence (TL) glow curves of pure and rare earth doped bismuth germanate (BGO) were investigated under UV and beta radiation. The glow curves of pure BGO crystal present different patterns for both kinds of radiation. The TL glow curves of BGO crystals doped with Nd ions are similar to that of pure BGO under UV radiation. The kinetic parameters, kinetic order (b), activation energy (E) and frequency factor (s) of the TL glow curves of pure BGO crystal have been determined by peak shape method. Activation energies of 3 peaks obtained by PS were found to be 1.81, 1.15 and 1.78, respectively. - Highlights: • Thermoluminescence properties of pure and Nd doped BGO crystals. • Irradiated by UV and beta for TL glow curve analysis. • Evaluation of kinetic parameters by PS method.

  8. Investigations on low temperature thermoluminescence centres in quartz

    International Nuclear Information System (INIS)

    Bernhardt, H.

    1984-01-01

    The present paper will help to understand the often investigated process of thermoluminescence of quartz which is of high complexity. A lot of traps exist in quartz crystals which compete with each other with respect to the trapping of charge carriers during the X-ray treatment. That is why a variety of processes takes place after X-irradiation at liquid nitrogen temperature (LNT) of quartz which complicate the phenomenology of low temperature thermoluminescence. This competition in the trapping process leads to the so-called 'sensibilization' or 'desensibilization' effects of thermoluminescence, respectively, which are described in this paper for the first time. This effect means the dependence of the LNT thermoluminescence intensity on a pre-irradiation dose applied at room temperature (RT). The influence of this pre-irradiation is understood assuming the saturation of competitive traps. This favours an enhanced trapping of charge carriers at LNT-(shallow) traps instead of the preferential trapping on the deep traps in the case of X-ray treatment of the as-grown crystal at LNT. To get the afore mentioned model we take into account not only thermoluminescence but also coloration, ir- and vuv-absorption measurements. (author)

  9. Inflammable materials stores

    International Nuclear Information System (INIS)

    Nandagopan, V.

    2017-01-01

    A new Inflammable Materials Stores has been constructed by A and SED, BARC near Gamma Field for storage of inflammable materials falling into Petroleum Class ‘A’ ‘B’ and “C” mainly comprising of oils and lubricants, Chemicals like Acetone, Petroleum Ether etc. which are regularly procured by Central Stores Unit (CSU) for issue to the various divisions of BARC. The design of the shed done by A and SED, BARC was duly got approved from Petroleum and Explosive Safety Organization (PESO) which is a mandatory requirement before commencement of the construction. The design had taken into account various safety factors which is ideally required for an inflammable materials stores

  10. Thermoluminescent dosimetry of new phosphors of Zn O exposed to beta radiation; Dosimetria termoluminiscente de nuevos fosforos de ZnO expuestos a radiacion beta

    Energy Technology Data Exchange (ETDEWEB)

    Cruz V, C.; Burruel I, S.E.; Grijalva M, H. [UNISON, A.P. 130, Hermosillo, Sonora (Mexico); Barboza F, M.; Bernal, R. [CIF, UNISON, A.P. 5-088, Hermosillo, Sonora (Mexico)

    2004-07-01

    In this work, we report the thermoluminescence dosimetry of a new Zn O phosphor obtained by annealing of Zn S powder precipitated when Zn S films were grown by employing a CBD method. The collected Zn S powder was pressed in a die to form pellets which were subjected to different thermal treatments under air atmosphere. X-ray diffraction (XRD) patterns and energy-dispersive X-ray Spectrometry (EDS) analyses confirmed the transformation of Zn S to Zn O. The phosphors thus obtained were exposed to high doses of beta radiation and their thermoluminescent dosimetry show that these new phosphors are materials suitable to be used in high dose thermoluminescence dosimetry. (Author)

  11. A fading-based method for checking the presence of closely overlapping peaks in thermoluminescent (TL) materials

    Science.gov (United States)

    Furetta, C.

    The paper describes a method, based on fading experiment, for determining the presence of a complex structure in the thermoluminescent glow curve emission from herbs, e.g. oregano and nopal. Because of the polymineral content of the inorganic part of these herbs, the emitted glow curve is the result of several overlapping glow peaks, each one corresponding to another mineral. The initial rise method is also used for determining the activation energy of each component.

  12. Information for Stores users

    CERN Multimedia

    FI Department

    2008-01-01

    The DISTRELEC catalogue (IT) is now available in EDH in addition to the CERN Stores catalogue and the catalogues of existing suppliers. Using an EDH materials request form, users can now order DISTRELEC equipment from amongst the following product groups: peripherals, multimedia, PC components, data media, communication and data cables and adapters. Non-authorised materials will be clearly indicated. As a reminder, the system automatically manages the distribution of standard Stores equipment and punch out equipment ordered on the same request form. In both cases, delivery will take a maximum of 48 hours. The approval of the EDH document will follow the usual EDH routing procedures. Logistics Group FI Department

  13. Laser readable thermoluminescent radiation dosimeters and methods for producing thereof

    International Nuclear Information System (INIS)

    Braunlich, P.F.; Tetzlaff, W.

    1989-01-01

    Thin layer thermoluminescent radiation dosimeters for use in laser readable dosimetry systems, and methods of fabricating such thin layer dosimeters are disclosed. The thin layer thermoluminescent radiation dosimeters include a thin substrate made from glass or other inorganic materials capable of withstanding high temperatures and high heating rates. A thin layer of a thermoluminescent phosphor material is heat bonded to the substrate using an inorganic binder such as glass. The dosimeters can be mounted in frames and cases for ease in handling. Methods of the invention include mixing a suitable phosphor composition and binder, both being in particulate or granular form. The mixture is then deposited onto a substrate such as by using mask printing techniques. The dosimeters are thereafter heated to fuse and bond the binder and phosphor to the substrate. 34 figs

  14. Effect of particle size on the thermoluminescent response of hydroxyapatite

    International Nuclear Information System (INIS)

    Barrera V, A.; Zarate M, J.; Contreras, M. E.; Rivera M, T.

    2016-10-01

    We present the study of the structural characterization and the thermoluminescent response of the hydroxyapatite as a function of the calcination temperature and the effect of the particle size. For precipitation synthesis, calcium nitrate (Ca(NO_3)_2 and dibasic ammonium phosphate ((NH_4)_2HPO_4) were used as precursors and ammonium hydroxide (NH_4OH) as a ph controlling agent. The characterization of the samples was carried out by the techniques of X-ray diffraction, scanning electron microscopy and infrared spectroscopy. The powders obtained are composed of hydroxyapatite, with a different degree of dehydroxylation. The thermoluminescent characterization indicates that at higher calcination temperature there is a higher thermoluminescent response, the calcined powders at 1300 degrees Celsius show a very well defined brightness curve with a higher intensity, with its maximum intensity located at a temperature of 210 degrees Celsius, which indicates that this material can be used as a dosimeter. (Author)

  15. Thermoluminescence of Zn O thin films deposited by chemical bath

    International Nuclear Information System (INIS)

    Camacho A, M. C.; Cruz V, C.; Bernal H, R.; Berman M, D.; Castano M, V. M.

    2015-10-01

    Full text: Zn O films on Si were synthesized using a deposition method by chemical bath and thermally treated at 900 degrees C for 12 h in air. The morphological characterization by scanning electron microscopy reveals that uniform films were obtained. To investigate the thermoluminescent properties of the films were exposed to irradiation with beta particles with doses in the range from 0.5 to 128 Gy. The brightness curves obtained using a heating rate of 5 degrees C have two peaks, one at 124 and another at 270 degrees C, and a linear dependence of the integrated thermoluminescence as a function of dose. The second maximum reveals the existence of localized trapping states of potential utility in thermoluminescent dosimetry. (Author)

  16. Shaktismen - hinduismens store gudindetradition

    DEFF Research Database (Denmark)

    Olesen, Bjarne Wernicke

    2008-01-01

    Artiklen giver en introduktion til shaktismen - hinduismens store gudindetradition. Den ser på de vigtigste gudinder, begreber, traditioner og forestillinger, ligesom den giver et vue over forskningssituationen. Shaktismens opståen i sin klassiske form, dens hovedretninger, virkelighedsforståelse...

  17. Information for stores users

    CERN Multimedia

    FI Department

    2008-01-01

    From the beginning of March onwards, the LYRECO (stationery) catalogue will be accessible from the Material Request form on EDH in the same way as the CERN Stores catalogue and the existing individual supplier catalogues. Items will be delivered within a maximum of 48 hours. Logistics Group FI Department

  18. Store Security: Reducing Shoplifting.

    Science.gov (United States)

    Minsel, Robert; Garman, Jerry

    The major purpose of the course outline presented in the document is the reduction of stealing in retail stores. The teaching outline is formatted by juxtaposing the content outline of each substantive area next to relevant activities and methods. Some of the topics covered are psychology of shoplifting, tools used by shoplifters, Ohio's law on…

  19. Study of a new glass matrix by the thermoluminescence technique

    International Nuclear Information System (INIS)

    Ferreira, Pamela Z.; Vedovato, Uly P.; Cunha, Diego M. da; Dantas, Noelio O.; Silva, Anielle C.A.; Neves, Lucio P.; Perini, Ana P.; Carrera, Betzabel N.S.; Watanabe, Shigueo

    2015-01-01

    The thermoluminescence technique is widely used for both personal and for high-dose dosimetry. In this work, the thermoluminescence technique was utilized to study a new glass matrix, with nominal composition of 20Li 2 CO 3 .10Al 2 O 3 .20BaO.50B 2 O 3 (mol%), irradiated with different doses in a 60 Co source. The glow curves and the dose-response curve were obtained for radiation doses between 50 Gy and 900 Gy. The results showed that this new glass matrix presents potential use in high-dose dosimetry. (author)

  20. Irradiated black pepper identification based on thermoluminescence of silicate minerals

    International Nuclear Information System (INIS)

    Faycal Kharfi; Randa Ketfi

    2018-01-01

    In this work we have successfully implemented thermoluminescence TL method for irradiated food identification. First tests are performed on Indian black pepper and show promising results to extend the proposed method to many other foods. The X-ray diffraction (XRD) shows that SiO 2 (p3 2 21) is the main component of the separated mineral phase. A saturation dose of ∼ 100 Gy is determined for this pepper above which all thermoluminescent centers of the quartz are activated. Thus, above this threshold dose, only the pepper irradiation will be confirmed but no accuracy on the exact dose received. (author)

  1. Thermoluminescence studies on plant seeds of different radiosensitivity

    International Nuclear Information System (INIS)

    Yamaguchi, Hikoyuki; Eguchi, Hoshio; Koizumi, Yoshinobu.

    1975-01-01

    The thermoluminescence was found when the pulverized powders from the whole seeds of six plant species or the hypocotyls from the seeds of five soybean varieties were irradiated at a liquid nitrogen temperature with gamma-rays. The spectra of luminescence emitted, the light peak temperature, the decaying after irradiation and the dose relationship of luminescence were determined. A high yield of the rapidly-decaying luminescence occurred in the more radiosensitive variety when irradiated with relatively lower doses. The very drastic decrease of the thermoluminescence was observed in the samples irradiated at room temperature prior to the exposure at 77 0 K. (auth.)

  2. Characterization of nanoDot optically stimulated luminescence detectors and high-sensitivity MCP-N thermoluminescent detectors in the 40-300 kVp energy range.

    Science.gov (United States)

    Poirier, Yannick; Kuznetsova, Svetlana; Villarreal-Barajas, Jose Eduardo

    2018-01-01

    To investigate empirically the energy dependence of the detector response of two in vivo luminescence detectors, LiF:Mg,Cu,P (MCP-N) high-sensitivity TLDs and Al 2 O 3 :C OSLDs, in the 40-300-kVp energy range in the context of in vivo surface dose measurement. As these detectors become more prevalent in clinical and preclinical in vivo measurements, knowledge of the variation in the empirical dependence of the measured response of these detectors across a wide spectrum of beam qualities is important. We characterized a large range of beam qualities of three different kilovoltage x-ray units: an Xstrahl 300 Orthovoltage unit, a Precision x-Ray X-RAD 320ix biological irradiator, and a Varian On-Board Imaging x-ray unit. The dose to water was measured in air according to the AAPM's Task Group 61 protocol. The OSLDs and TLDs were irradiated under reference conditions on the surface of a water phantom to provide full backscatter conditions. To assess the change in sensitivity in the long term, we separated the in vivo dosimeters of each type into an experimental and a reference group. The experimental dosimeters were irradiated using the kilovoltage x-ray units at each beam quality used in this investigation, while the reference group received a constant 10 cGy irradiation at 6 MV from a Varian clinical linear accelerator. The individual calibration of each detector was verified in cycles where both groups received a 10 cGy irradiation at 6 MV. The nanoDot OSLDs were highly reproducible, with ±1.5% variation in response following >40 measurement cycles. The TLDs lost ~20% of their signal sensitivity over the course of the study. The relative light output per unit dose to water of the MCP-N TLDs did not vary with beam quality for beam qualities with effective energies <50 keV (~150 kVp/6 mm Al). At higher energies, they showed a reduced (~75-85%) light output per unit dose relative to 6 MV x rays. The nanoDot OSLDs exhibited a very strong (120

  3. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of peaks of high temperature in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.

    2007-01-01

    The increase of the applications of ion beams in radiotherapy treatments has generated interest in the study of the thermoluminescent materials (TL) that allow to determine the applied doses. A way to quantify the TL response from these materials to ions is by means of the relative thermoluminescent efficiency. In the group of Thermoluminescent dosimetry of the Institute of Physics of the UNAM (IFUNAM) the thermoluminescent response of the TLD-100 dosemeters has been studied, which present a glow curve characteristic with several peaks that correspond to traps and luminescent centers in the material. The stable peaks know each other as 4, 5, 6a, 6b, 7, 8, 9 and 10. The efficiencies should be measured using the response so much to the radiation of interest (in this case protons and helium ions) as the response to gamma radiation. In previous works with ions of low energy taken place in the Pelletron accelerator of the IFUNAM was only measured the TL efficiency for the peak 5 and the total signal. It had not been possible to measure the efficiency of the peaks of high temperature (6a-10) because, for the gamma radiation, the peaks of high temperature show very small signals; however, recently Massillon carries out measures of efficiency TL of peaks of high temperature for ions of intermediate energy using a protocol special of reading and of deconvolution that allows to measure the signals coming from the peaks of high temperature. In this work is implemented this same protocol to complete the study of TL efficiencies at low energy of protons and helium and to determine if the values of efficiency depend on the used reading protocol. For it is reported it measures of the relative efficiency of the peaks of high temperature from the TLD-100 exposed to protons of 1.5 MeV and nuclei of helium of 3 and 7.5 MeV. (Author)

  4. Evaluation of new and conventional thermoluminescent phosphors for environmental monitoring using automated thermoluminescent dosimeter readers

    International Nuclear Information System (INIS)

    Rathbone, B.A.; Endres, A.W.; Antonio, E.J.

    1994-10-01

    In recent years, there has been considerable interest in a new generation of super-sensitive thermoluminescent (TL) phosphors for potential use in routine personnel and environmental monitoring. Two of these phosphors, α-Al 2 O 3 :C and LiF:Mg,Cu,P, are evaluated in this paper for selected characteristics relevant to environmental monitoring, along with two conventional phosphors widely used in environmental monitoring, LiF:Mg,Ti and CaF 2 :Dy. The characteristics evaluated are light-induced fading, light-induced background, linearity and variability at low dose, and the minimum measurable dose. These characteristics were determined using an automated commercial dosimetry system (Harshaw System 8800) and routine processing protocols. Annealing and readout protocols for each phosphor were optimized for use in a large-scale environmental monitoring program

  5. Dry fuel store for advanced gas cooled reactor fuels

    International Nuclear Information System (INIS)

    Grant, J.S.; Boocock, P.M.; Ealing, C.J.

    1992-01-01

    This paper summarizes the fuel storage requirements in Scotland and the selection of a Dry Fuel Store of the Modular Vault Dry Store (MVDS) design developed by GEC ALSTHOM Engineering Systems Limited (GECA). A similar design of store has been selected and has been constructed in the USA by Foster Wheeler Energy Corporation in collaboration with GECA

  6. STORE IN STORE FRANCHISING STRATEGY: THE TREND IN FRANCHISING NEGOTIATION

    OpenAIRE

    Rosado-Serrano, Alexander; Universidad de Puerto Rico

    2016-01-01

    The literature on franchising has traditionally focused on the effects and transformation it has promoted in the service sector, retailing, restaurants, hotels and other service-related industries. Store within a store research has been focused on the perspective of the manufacturer entering department stores. To date, little research has been carried out for the store in store strategy from the franchising perspective. This paper explores why big box retailers such as Walmart are adopting th...

  7. Thermoluminescent dosimetry in dentistry students in radiological training

    International Nuclear Information System (INIS)

    Loya, M.; Duarte, R.; Montero, M.E.; Gonzalez, P.R.; Ojeda, S.L.; Sanin, L.H.

    2007-01-01

    Full text: In this work, the obtained results of the mensuration of the equivalent one are presented of dose (E), in students of the career of Dentistry who during their training in radiology complete the three lists of patient, odontologist and observer. The study one carries out with 35 students (Odontologists), 7 men and 28 women, with ages between 20 and 24 years. A characterization of risk was made following the methodology of the Agency for the environmental control of United States (EPA), counting the number of shots in each list, during the time of training. The effective energy of the X rays used was of 24 KeV. The irradiation technique understood two modalities; the first one with 3 shots of 1.25 seconds and the second with 5 shots of 0.6 seconds. The measurement of E, was carried out with thermoluminescent dosemeters (TL) of LiF:Mg,Cu,P+PTFE, developed in the National Institute of Nuclear Research (ININ). The homogenization of the dosemeters showed a variation in its response to the radiation of 1.85%DS. For the odontologist position, the dosemeters was placed to the height of the chest and the measurement was multiplied by the number of shots that it was 304. The E value was of 3.62 mSv/four-month (11 mSv/year), without any safety equipment and of 2.02 mSv/four-month (6.14 mSv/year), when was considered the scenario for this position with use of vest and lead collar, like safety equipment, diminishing E, almost 50%. In the case of the corresponding position to patient, E, it was measured in different organs of interest, the obtained results are compared with the international standards. Recommendations are given for similar cases. (Author)

  8. Thermoluminescence of cerium and terbium -doped calcium pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Roman L, J.; Cruz Z, E. [UNAM, Instituto de Ciencias Nucleares, Circuito Exterior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Lozano R, I. B.; Diaz G, J. A. I., E-mail: jesus.roman@nucleares.unam.mx [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria No. 694, 11500 Mexico D. F. (Mexico)

    2015-10-15

    The aim of this work is to report the thermoluminescence (Tl) response of Calcium Pyrophosphate phosphor doped with Cerium and Terbium impurities (Ca{sub 2}P{sub 2}O{sub 7}:Ce{sup 3+},Tb{sup 3+}). The phosphors were synthesized using the co-precipitation method and annealed at 900 degrees C by two hours for obtain the β phase. The intentional doping with Ce and Tb ions was 1 at.% and 0.1 at.%, whereas in the EDS results the concentration of impurities was 0.39 at.% and 0.05 at.%, respectively. The superficial morphology of phosphor is mainly composed by thin wafers of different size. All samples were exposed to gamma rays from {sup 60}Co in the Gammacell-200 irradiator. The Tl response of the phosphor was measured from Rt up to 350 degrees C and under nitrogen atmosphere in a Harshaw TLD 3500 reader. The glow curves of the Ca{sub 2}P{sub 2}O{sub 7}:Ce{sup 3+},Tb{sup 3+} powders showed a broad intense Tl peak centered at 165 degrees C and a shoulder at approximate 260 degrees C was observed. A linear Tl response in the range of absorbed dose of 0.2 to 10 Gy was obtained. Tl glow curves were analyzed using the initial rise (IR)and computerized glow curve deconvolution methods to evaluate the kinetics parameters such as activation energy (E), frequency factor (s) and kinetic order (b). (Author)

  9. Effect of phase transitions on thermoluminescence characteristics of nanocrystalline alumina

    International Nuclear Information System (INIS)

    Rani, Geeta; Sahare, P.D.

    2013-01-01

    Highlights: •Synthesis of Al 2 O 3 nanocrystalline TLD phosphor. •Material characterizations by XRD, TEM and TL. •Change in structure and morphology of the phase transition alumina. •Change in glow curve structures and trapping parameters on phase transitions. -- Abstract: Nanocrystalline boehmite (γ-AlOOH) was synthesized by hydrothermal method using AlCl 3 ·6H 2 O and Urea as precursors. The material gets decomposed to form the γ-Al 2 O 3 phase at around 873 K on annealing in air. On annealing further at higher temperatures it gets converted into different phases, such as, δ, θ and the most stable α-phase. Not only the phase changes but the annealing has also changed the morphology of the nanomaterial, i.e. it has changed from spindle like edges to vermicular structures and also grew bigger in sizes. The formations of different phases were confirmed by the X-ray diffraction (XRD) patterns and the changes in the morphology were seen through the TEM images. Further the effect of different phases on the thermoluminescence (TL) glow curve structures was studied and it is also shown that the TL glow curves structures do change due to phase transformations. To investigate further and to determine trapping parameters, different glow curves have been theoretically deconvoluted using computerized glow curve deconvolution (CGCD method) into simple glow peaks. The values of different trapping parameters also change as the glow curve structures on phase transformations due to reorganization of energy levels and the stress/strain generated by some intermediate phases

  10. The red thermoluminescence of quartz: 3-D spectral measurements

    International Nuclear Information System (INIS)

    Scholefield, R.B.; Prescott, J.R.

    1999-01-01

    As part of a general study of the thermoluminescence (TL) of quartz, we have examined the 3-D spectra of samples of quartz extracted from a variety of sediments. Blue emission at about 2.6 eV/475 nm, which is the photon energy region commonly used in luminescence dating, seems ubiquitous. Significant emission in the red, ∼1.9 eV/650 nm, has been found at most glow temperatures in all of our samples of Australian quartz sediments, and it is to this that particular attention is paid in the present work. A limited selection of samples from other countries has also been included. The ratio of the intensities of the red and blue emissions varies widely among samples. We have not found any evidence of a correlation between this ratio, nor the intensity of the red emission, with trace element concentration, including that of Al for which a correlation has been previously observed. In the context of luminescence dating, all samples have been examined to see whether they have a rapidly bleaching red component in a similar sense to the well-known 305 deg. C/2.95 eV/420 nm peak in quartz: some samples have such a component--some do not. A suggestive parallelism is found between the blue and red spectra, in that there are 'slowly bleaching' and 'rapidly bleaching' components at similar temperatures in the both red and the blue. However, there is no red component associated with the 110 deg. C peak used in pre-dose dating

  11. Thermoluminescent response of LiF: Mg, Cu, P (GR-200) below an electron beam of 6 MeV

    International Nuclear Information System (INIS)

    Torijano C, E.F.S.; Azorin N, J.; Villasenor N, I.; Lujan C, P.J.; Rivera M, T.

    2007-01-01

    Full text: In this work the experimental results of studying the thermoluminescent response (TL) of LiF:Mg,Cu,P (GR-200) previously irradiated with 6 MeV electrons are presented. The electrons beam was generated by a Lineal Accelerator VARIAN I for medical use. The lineal accelerator is installed in the General Hospital of Mexico (HGM). A lot of 25 thermoluminescent dosemeters (DTL) was used. The mass and volume of each one of them were determined. Obtaining a variation of 14% in standard deviation (SD). The DTLs were irradiated to an energy of 6 MeV. The dose given to the DTL was of 50 c Gy. The linearity of the response of the GR-200 also was determined. (Author)

  12. Analysis of Danish energy research: are the funds sufficient, and are the priorities the right ones?; Analyse af dansk energiforskning: er bevillingerne store nok, og er prioriteringerne rigtige?

    Energy Technology Data Exchange (ETDEWEB)

    Rosenhagen, C. (COWI A/S, Kgs. Lyngby (Denmark)); Hougaard Jensen, S.E. (Centre For Economic and Business Research (CEBR), Frederiksberg (Denmark)); Moellgaard, P.; Nielsen, Soeren Bo (Copenhagen Business School, Copenhagen (Denmark))

    2009-09-15

    One of Denmark's official energy policy objectives is that Denmark must be independent of fossil fuels in the long term (2050). In addition, Denmark has committed itself to targets at the medium term (2020), which implies a much higher proportion of renewable energy in total energy supply and a marked lower emission of greenhouse gases. An assessment of the Danish energy research must be considered in conjunction with these broad objectives. Additionally the energy research must be assessed from its socio-economic importance, including its contribution to economic growth and productivity. Danish energy research has shown that it is possible to create good research environments and results at a high international level. Danish energy research are today carried out in close international cooperation, and Danish energy researchers are good at getting EU research funding. The analysis indicates that both co-financing from abroad and from industry are significantly higher for Danish energy research than for Danish research in general. There are Danish strongholds within the technologies which the International Energy Agency (IEA) has estimated to provide the highest cost reduction, including fuel cells, electric cars, solar cells and geothermal heat pumps. With Risoe / DTU as the leading institute and with larger environments at other universities, Denmark has managed to develop specific competencies in several renewable technologies and in development and integration of the electricity system. Despite statements of wanting to be the 'pioneer' country, Denmark does not give energy research especially high priority. Thus, public funding for energy research is only 7-8% of the total public research funding, which corresponds to OECD average. The research funding system for energy has been characterized by considerable instability in funding over a longer period of time ('stop-go'). This weakens the possibilities for long term planning of research

  13. Calibration of Mg2SiO4(Tb) thermoluminescent dosimeters for use in determining diagnostic X-ray doses to Adult Health Study participants

    International Nuclear Information System (INIS)

    Kato, Kazuo; Antoku, Shigetoshi; Sawada, Shozo; Russell, W.J.

    1989-11-01

    Characteristics of Mg 2 SiO 4 (Tb) thermoluminescent dosimeters (TLD) were ascertained preparatory to measuring dose from diagnostic X-ray examinations received by Adult Health Study participants. These detectors are small, relatively sensitive to low-dose X rays, and are appropriate for precise dosimetry. Extensive calibration is necessary for precisely determining doses according to their thermoluminescent intensities. Their sensitivities were investigated, by dose according to X-ray tube voltage, and by exposure direction, to obtain directional dependence. Dosimeter sensitivity lessened due to the fading effect and diminution of the planchet. However, these adverse effects can be avoided by storing the dosimeters at least 1.5 hours and by using fresh silver-plated planchets. Thus, the TLDs, for which sensitivities were determined in this study, will be useful in subsequent diagnostic X-ray dosimetry. (author)

  14. Values of dose and individual of a individual thermoluminescent dosimeter submitted to x and gamma radiations

    International Nuclear Information System (INIS)

    Moraes, Cassiana Viccari de; Pela, Carlos Alberto

    2001-01-01

    The individual monitoring provides information for the control of exposures, and estimates the dose received by individuals. This is an essential tool in personal dosimetry. It's based on a radiation protection concept, allowing an individual exposure control, besides guaranteeing that the dose restrictions will not be exceeded. Usually, the dose monitoring is performed by using an individual dosemeter placed on a representative position of the most exposed point on the thoracic surface. The dosemeter, which is analyzed in the present work, is made of three CaSO 4 -Dy thermoluminescent detectors, plastic filters, copper and copper-lead, mounted in an acrylic support. The dose received by on each detector, which forms the dosemeter, is related according to their energetic curve dependence. The dose amount is calculated from these curves by using an algorithm, and it was taken in to consideration the detector calibration and thermoluminescent responses, due to the x and g radiation exposure. That algorithm has the capacity to determine the energies that were irradiated the detector. Therefore, to aid the service in the moment of evaluate the dose received by the individual and where it is coming from. The algorithm has provided individual dose value H x , defined as operational quantity for photons adopted in the Brazilian Metric System. The algorithm can determine two dose values and such values have been analyzed according to the kind of irradiated energy on the dosimeter and it has shown that both values are within established limits by Instituto de Radioprotecao e Dosimetria (IRD). (author)

  15. Leaked filters for energetic and angular dependence corrections of thermoluminescent response

    International Nuclear Information System (INIS)

    Manzoli, Jose Eduardo; Shammas, Gabriel Issa Jabra; Campos, Vicente de Paulo de

    2007-01-01

    Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility and small fading. The phosphors advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. Calcium Sulfate Dysprosium doped (CaSO 4 :Dy) and Calcium Fluoride Manganese doped (CaF 2 :Mn) phosphor Thermoluminescent Dosimeters (TLDs) have been used by many laboratories. They are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs main disadvantage is the strong energetic dependence response, which must be corrected for theirs application in routine, where the kind of photon radiation is unknown a priori. An interesting way to make this correction is to interject a leaked filter between the beam and the phosphor, where the beam could strike the phosphor at any angle. In order to reduce the energetic dependence on any incidence angle, this work presents experimental and simulation studies on some filter geometries. It was made TL readings and simulations on TL responses to photon irradiations with gamma rays of 60 Co and X-rays of 33; 48 and 118 keV, on many incidence angles from zero to ninety degrees. The results pointed out the best filter thicknesses and widths, in order to optimize the correction of energetic dependence for the studied geometries. (author)

  16. Measurement of gamma radiation doses at the RA reactor by thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Prokic, M.

    1974-01-01

    This paper presents the procedures and gamma radiation doses measured at the exit from the horizontal experimental channel HK-5, vertical experimental channel VK-5 and in the thermal column of the RA reactor in Vinca. Measurement of gamma radiation dose in the mixed intense gamma and neutron radiation field was done by two types of thermoluminescent dosemeters, LiF (TLD-700) and CaF 2 (TLD-08). Gamma dose in the VK-5 was measured in the air and on the bottle filled with tissue-equivalent solution. Increase of the dose on the surface of the bottle was 2.3 compared to the gamma dose value in the air. Correction for the influence of neutrons having different energies was done by using the known sensitivity values of both TL dosemeter types for thermal, intermediate and fast neutrons. Results showed that the TLD-700 dosemeter contains 5 time more Li-6 isotopes (0.035%) than the declared value causing increased neutron sensitivity of this dosemeter. This paper includes numerical sensitivity data for neutrons of different energies for both types of TL dosemeters. Neutron sensitivity values for TLD-700 are related to LiF with 0.035% of Li-6 isotope. Result of measurement have also shown that the CaF 2 :Mn (TLD-08) thermoluminescent dosemeter is more suitable for gamma radiation dose measurements in mixed n-gamma fields with intensive neutron fluxes due to lower neutron sensitivity compared to TLD-700 [sr

  17. A 10 TW pulsed energy complex PIRIT-2000 for investigation of short-wave radiation

    Energy Technology Data Exchange (ETDEWEB)

    Popkov, N F; Ryaslov, E A; Kargin, V I; Pikar` , A S; Vorontsov, V I; Kotel` nikov, D V; Melkozerov, A V [All-Russian Scientific Research Inst. of Experimental Physics, Sarov (Russian Federation)

    1997-12-31

    The results of investigation of a pulsed plasma x-ray source at the PIRIT-2000 fast operating capacitor bank are reported. The maximum energy stored in a primary 54-module capacitive storage at the output voltage of 500 kV reaches 2 MJ. The capacitor bank energizes a vacuum inductive storage, which is commutated by a plasma opening switch. The plasma diode consists of a tube cathode of diameter 15 cm and of a larger tube anode with six plasma injecting guns. The current amplitude and the current rise time at the plasma load amounts to 4 MA and 150 ns, respectively. The x-ray doses were measured by means of thermoluminescent dosemeters and the integral radiation output by means of a thermocouple calorimeter. The radiation output as high as 100 kJ was achieved at the stored energy of 1 MJ. (J.U.). 4 figs., 4 refs.

  18. Ultrasonic-energy enhance the ionic liquid-based dual microextraction to preconcentrate the lead in ground and stored rain water samples as compared to conventional shaking method.

    Science.gov (United States)

    Nizamani, Sooraj; Kazi, Tasneem G; Afridi, Hassan I

    2018-01-01

    An efficient preconcentration technique based on ultrasonic-assisted ionic liquid-based dual microextraction (UA-ILDµE) method has been developed to preconcentrate the lead (Pb +2 ) in ground and stored rain water. In the current proposed method, Pb +2 was complexed with a chelating agent (dithizone), whereas an ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) was used for extraction purpose. The ultrasonic irradiation and electrical shaking system were applied to enhance the dispersion and extraction of Pb +2 complex in aqueous samples. For second phase, dual microextraction (DµE phase), the enriched Pb +2 complex in ionic liquid, extracted back into the acidic aqueous solution and finally determined by flame atomic absorption spectrometry. Some major analytical parameters that influenced the extraction efficiency of developed method, such as pH, concentration of ligand, volume of ionic liquid and samples, time of shaking in thermostatic electrical shaker and ultrasonic bath, effect of back extracting HNO 3 volume, matrix effect, centrifugation time and rate were optimized. At the sample volume of 25mL, the calculated preconcentration factor was 62.2. The limit of detection of proposed procedure for Pb +2 ions was found to be 0.54μgL -1 . The validation of developed method was performed by the analysis of certified sample of water SRM 1643e and standard addition method in a real water sample. The extraction recovery of Pb +2 was enhanced≥2% with shaking time of 80s in ultrasonic bath as compared to used thermostatic electrical shaker, where for optimum recovery up to 10min was required. The developed procedure was successfully used for the enrichment of Pb +2 in ground and stored rain water (surface water) samples of an endemic region of Pakistan. The resulted data indicated that the ground water samples were highly contaminated with Pb +2 , while some of the surface water samples were also have higher values of Pb +2 than permissible limit of

  19. Chronology of Chichen Izta, evidences by thermoluminescence

    International Nuclear Information System (INIS)

    Ramirez, A.; Schaaf, P.; Gonzalez, P.R.; Chung, H.

    2002-01-01

    The establishment of the chronology of Chichen Itza is argued by its stylistic evocations, architectural and iconographical as well as its history related in the sources, as the Chilam Balam, where is named the arrival of foreign tribes as the Xiu and the Itzaes and its settlement in Chichen Itza as well as the return to its origin place. The material evidence of such transition is reflected in the ceramic change of the Pizarra Puuc to the Pizarra Chichen, however, in 13 stratigraphic wells realized in different points of Chichen Itza, it was not found evidence of the layer of the Pizarra Puuc period. In this work the obtained ages of dating by thermoluminescence (TL) are presented, of four samples of ceramics found in the different wells. When our results are compared with the estimated ages for the different groups of ceramics, it was observed that none of they corresponded to the Pizarra Puuc period. These results strenghten the observations realized during excavations, causing the suggestion of new inferences related to the Chichen Itza boom and its relationship with the Maya Classic Period. The used technique for the TL dating was that of fine grain. The interval of artificial dose, of beta radiation of Strontium 90 was between 2 and 30 Gy. The TL signal was obtained heating the samples at 10 C/s until reaching 500 C in the TL Daybreak reader equipment. In order to know the annual dose rate of concentration of potassium ( 40 K) by means of the microanalysis technique in the scanning electron microscope was determined, while the uranium content (2 38 U) and thorium ( 232 Th) were determined by means of the neutron activation analysis technique using the TRIGA Mark III nuclear reactor. The contribution of the gamma radiation of the soil as well as the contribution of the cosmic radiation was measured with TL dosemeters of CaSO 4 :Dy + Ptfe once the paleodose was known and the annual dose rate of each sample of its age was estimated. (Author)

  20. Fuel element store

    International Nuclear Information System (INIS)

    Wieser, R.

    1987-01-01

    The spherical fuel elements are stored dry in cans. The cans themselves are stacked in parallel storage shafts, which are combined into a rectangular storage space. The storage space is made earthquake-proof by surrounding it with concrete. It consists of a ceiling assembled from several steel parts, which is connected to the floor by support elements. A cooling air ventilation station supplies the individual storage shaft and therefore the cans with cooling air via incoming and outgoing pipes. (DG) [de

  1. Air corrosion in storing

    International Nuclear Information System (INIS)

    Mazaudier, F.; Feron, D.; Baklouti, M.; Midoux, N.

    2001-01-01

    The air corrosiveness of a radioactive waste package has been estimated in a store inside which the environmental conditions are supposed to be rather close to the outside ones. It is expressed according to the ISO 9223 standard, from the humidification value and the amounts of sulfur dioxide and chlorine ions. A computer code has been perfected too; the thermal behaviour of the package can then been determined. (O.M.)

  2. Store and forward teledermatology

    Directory of Open Access Journals (Sweden)

    Kanthraj Garehatty

    2007-01-01

    Full Text Available Store and forward and real time or videoconferences are the two types of teledermatology services practiced. Dermatology and radio-diagnosis are visual specialties suited for store-and-forward teledermatology (SAFT. Advances in information technology, electronic instruments and biotechnology have revolutionized and brought changes in SAFT. Cellular phone, digital camera, personal digital assistants, Wi-Fi, Wi-Max and computer- aided-design software are incorporated to deliver the quality health care to remote geographic regions. Complete SAFT care equivalent to face-to-face consultation (Gold standard is essential. Health care providers in rural areas are the ′eyes′ for the consultants. Consultants to guide them should have a rapid periodic audit of visual parameters and dimensions of lesions. Given this background, this article reviews advances in 1 capture, store and transfer of images. 2 Computer Aided measurements of generalized and localized lesions and 3 the integration model to meet all the above two requirements in a centralized location. This process enables diagnosis, management, periodic assessment and complete follow-up care to achieve patient and physician satisfaction. Preservation of privacy and confidentiality of digital images is important. Uniform rules and regulations are required. Indian space research organization (ISRO, Government of India has demonstrated telemedicine pilot projects utilizing the satellite communication and mobile telemedicine units to be useful in meeting the health care needs of remote and rural India. we have to join hands with them to meet dermatology problems in rural areas.

  3. The evolution with strain of the stored energy in different texture components of cold-rolled IF steel revealed by high resolution X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Wauthier-Monnin, A. [LSPM–CNRS, Université Paris 13, 99, Av. J.B. Clément, 93430 Villetaneuse (France); ArcelorMittal Research Voie Romaine BP 30320, 57 283 Maizières-les Metz (France); Chauveau, T.; Castelnau, O. [LSPM–CNRS, Université Paris 13, 99, Av. J.B. Clément, 93430 Villetaneuse (France); Réglé, H. [ArcelorMittal Research Voie Romaine BP 30320, 57 283 Maizières-les Metz (France); Bacroix, B., E-mail: brigitte.bacroix@univ-paris13.fr [LSPM–CNRS, Université Paris 13, 99, Av. J.B. Clément, 93430 Villetaneuse (France)

    2015-06-15

    During the deformation of low carbon steel by cold-rolling, dislocations are created and stored in grains depending on local crystallographic orientation, deformation, and deformation gradient. Orientation dependent dislocation densities have been estimated from the broadening of X-ray diffraction lines measured on a synchrotron beamline. Different cold-rolling levels (from 30% to 95% thickness reduction) have been considered. It is shown that the present measurements are consistent with the hypothesis of the sole consideration of screw dislocations for the analysis of the data. The presented evolutions show that the dislocation density first increases within the α fiber (=(hkl)<110>) and then within the γ fiber (=(111)). A comparison with EBSD measurements is done and confirms that the storage of dislocations during the deformation process is orientation dependent and that this dependence is correlated to the cold-rolling level. If we assume that this dislocation density acts as a driving force during recrystallization, these observations can explain the fact that the recrystallization mechanisms are generally different after moderate or large strains. - Highlights: • Dislocation densities are assessed by XRD in main texture components of a steel sheet. • Dislocation densities vary with both strain and texture components. • The analysis relies on the sole presence of screw dislocations. • The measured dislocation densities include the contribution of both SSD and GND.

  4. Thermoluminescence dating of late Devensian loesses in southern England

    International Nuclear Information System (INIS)

    Wintle, A.G.

    1981-01-01

    The results are reported of thermoluminescence dating of six relatively recent deposits of loess-like material from southern Britiain between the Scilly Isles and Kent. The dates have been obtained on the loess itself and confirm the ages as being late Devensian. (U.K.)

  5. The thermoluminescence of carp otoliths: A fingerprint in ...

    African Journals Online (AJOL)

    This paper reports a pilot study on the thermoluminescence (TL) of carbonate minerals of carp otoliths from the heavily polluted Baiyangdian Lake (BYD) in Hebei Province and non-polluted Miyun Water Reservoir (MY) in Beijing Municipality of China. Analyses on trace elements of otoliths and water show that the heavy ...

  6. Dose measurements in dental radiology using thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Chiara, Ana Claudia M. de; Costa, Alessandro M.; Pardini, Luiz Carlos

    2009-01-01

    The aim of this work was the implementation of a code of practice for dosimetry in dental radiology using the technique of thermoluminescent dosimetry. General principles for the use of thermoluminescent dosimeters were followed. The irradiations were performed using ten X-ray equipment for intra-oral radiography and an X-ray equipment for panoramic radiography. The incident air kerma was evaluated for five different exposure times used in clinical practice for intra-oral radiographs. Using a backscatter factor of 1.2, it was observed that approximately 40% of the entrance skin dose values found for intra-oral radiographs are above the diagnostic reference level recommended in national regulation. Different configurations of voltage and current were used representing the exposure as a child, woman and man for panoramic radiographs. The results obtained for the air kerma area product were respectively 53.3 +- 5.2 mGy.cm 2 , 101.5 +- 9.5 mGy.cm 2 and 116.8 +- 10.4 mGy.cm 2 . The use of thermoluminescent dosimetry requires several procedures before a result is recorded. The use of dosimeters with ionization chambers or semiconductors provides a simple and robust method for routine measurements. However, the use of thermoluminescent dosimetry can be of great value to large-scale surveys to establish diagnostic reference levels. (author)

  7. Thermically stimulated exoelectronic emissions and thermoluminescence of MgO

    International Nuclear Information System (INIS)

    Chubaci, J.F.D.

    1987-01-01

    In this work, studies were performed on the following topics: i) thermically stimulated exoelectronic emission (TSEE) in pure MgO single crystals ion implanted, submitted to thermal treatment with fast on slow cooling and water adsorption; ii) ultraviolet light effect on TSEE; iii) thermoluminescent emission; iv) crystallization of FeCoB amorphous alloys. (A.C.A.S.) [pt

  8. The thermoluminescence of carp otoliths: A fingerprint in ...

    African Journals Online (AJOL)

    use

    2011-12-14

    Dec 14, 2011 ... provide a quick and qualitative means for environmental assessments in lake pollution. Key words: Thermoluminescence, fish otolith, heavy-metal elements, lake, pollution. INTRODUCTION. Fish otoliths are widely .... cleaned HDPE plastic bottles that have been rinsed with sample three times prior to use.

  9. Application of numerical analysis methods to thermoluminescence dosimetry

    International Nuclear Information System (INIS)

    Gomez Ros, J. M.; Delgado, A.

    1989-01-01

    This report presents the application of numerical methods to thermoluminescence dosimetry (TLD), showing the advantages obtained over conventional evaluation systems. Different configurations of the analysis method are presented to operate in specific dosimetric applications of TLD, such as environmental monitoring and mailed dosimetry systems for quality assurance in radiotherapy facilities. (Author) 10 refs

  10. Spatially-resolved thermoluminescence from snail opercula using an EMCCD

    DEFF Research Database (Denmark)

    Duller, G.A.T.; Kook, Myung Ho; Stirling, R.J.

    2015-01-01

    In recent years opercula of the snail species Bithynia tentaculata have been shown to emit thermoluminescence (TL) signals that can be used to determine equivalent dose, and may be capable of dating events throughout the entire Quaternary period. Concentric growth lines are a notable feature of a...

  11. Deconvolution of the thermoluminescent emission curve. Second order kinetics

    International Nuclear Information System (INIS)

    Moreno y M, A.; Moreno B, A.

    1999-01-01

    In this work it is described the Randall and Wilkins second order kinetics in Microsoft Excel language, which allows its expression as the sum of Gaussian and the correction factors corresponding. These factors are obtained of the differences between the real thermoluminescent curve and the Gaussian proposed. The results obtained justify the Gaussian expression added to the correction factor. (Author)

  12. The first Spanish prototype for storing energy in a superconductor cylinder. Primer prototipo espanol de almacenamiento de energia en bobina superconductora

    Energy Technology Data Exchange (ETDEWEB)

    Iglesias Diaz, I.; Garcia-Tabares Rodriguez, L.; Tamarit Rodriguez, J. (CEDEX. MORT (Spain))

    1992-12-01

    This paper describes the first test of a Superconducting Magnetic Energy Storage (SMES) of 20 KJ at 4.2 degree K which has been developed within the framework of a common agreement between four Institutions: ACICA, CEDEX, ICMA and MIDAS,being the second part of a report already published in this review entitled ''A 10 Tesla Superconducting Solenoid of Energy Storage.'' After a brief description of how SMES works and which are its main components, a more detailed definition of the tests which have been carried out is presented. These tests demonstrate that a very high efficiency can be achieved in the entire process of charging and discharging the coil throughout a six pulses converter, establishing a very reliable procedure of injecting and extracting energy to the electrical grid. Finally, future trends in the field of SMES are briefly described and which be their main applications. (Author)

  13. Application of thermoluminescence measurements to detect low dose gamma-irradiated table grapes

    International Nuclear Information System (INIS)

    Sillano, O.; Rubio, T.; Espinoza, J.; Roman, A.; Deza, A.

    1994-01-01

    A major factor hampering the introduction of ionizing radiation as an alternative quarantine treatment to chemical fumigation for fruit and vegetables is the lack of reliable, simple and inexpensive post-treatment methods to confirm this low dose irradiation treatment. Thermoluminescence (TL) measurements of the wind blown dust naturally adhering to the surface of table grapes, was surveyed. Two doses, 0.5 and 1.0 kGy, were studied, applied to the main Chilean table grape export varieties: Thompson Seedless and Flame Seedless. TL measurements were carried out over 78 days for Thompson Seedless and 62 days for Flame Seedless varieties, both stored at 1 ± 1 o C. TL response fading of dust samples stored at room temperature was also followed over 125days. The TL response values obtained from the irradiated samples exceeded at least 3 times the highest ones obtained from the unirradiated counterparts. The treatment, even for the lower γ-radiation dose applied, could be properly detected well above the shipping and marketing time for this Chilean export fruit (2-8 weeks). This method also has the advantage of using relatively inexpensive equipment. (author)

  14. Dating of aragonite and dolomite from Devil's cave - SP, by dosimetric thermoluminescent method (DTL) and ESR

    International Nuclear Information System (INIS)

    Tatumi, S.H.

    1987-01-01

    We have investigated TL (Thermoluminescence) and ESR (electron spin resonance) properties of aragonite and dolomite found at ''Caverna do Diabo (Devil's cave)'' in the state of Sao Paulo to determine the ages of these geological materials. The aragonite, which is not a thermoluminescent material, shows one ESR signal whit g = 2.003. We obtained the age of 1.1 x 10 5 years and the growth rate of 1 μ m/year by the sample calibration with additional Y irradiation. The dolomite gives a TL glow curve with three distinct peaks at 261, 334 and 395 0 C. We found that the fit for the TL glow curve to second-order kinetics can be considerered as very acceptable. Using the second TL peak we obtained the age of 9.4 x 10 5 years and the compatible values of the activation energy (1.90 ± 0,07 eV) by the following methods: Hyperbolic heating, isothermal decay and fractional glow technique. We observed many ESR absorption signals in the dolomite. Three principal signal com g = 2.002, 2.003 and 2.005 were studied. We found that the first and second ESR signals were atributed to the CO 2 - and/or CO 3 3- centers and the last to the CO 3 - centers, and observed that the first ESR signal might related with the second TL peak and the TL sensitivity were associated with the concentration of Mn 2+ [pt

  15. Thermoluminescence dosimetry: State-of-the-art and frontiers of future research

    International Nuclear Information System (INIS)

    Horowitz, Y.S.

    2014-01-01

    The state-of-the-art in the use of thermoluminescence for the measurement of energy imparted by ionizing radiation is discussed. Emphasis is on the advantages obtainable by the use of computerized glow curve analysis in (i) quality control, (ii) low dose environmental dosimetry, (iii) medical applications (especially precision) and microdosimetric applications, and (iv) mixed field ionization-density–dosimetry. Possible frontiers of future research are highlighted: (i) vector representation in glow curve analysis, (ii) combined OSL/TL measurements, (iii) detection of sub-ionization electrons, (iv) requirements for new TL materials and (v) theoretical subjects involving kinetic modeling invoking localized/delocalized recombination applied to dose response and track structure theory including creation of defects. - Highlights:: • State of the art in thermoluminescence dosimetry. • Benefits of computerized glow curve deconvolution. • Frontiers of future research:new materials, mixed-field dosimetry. • Localized/delocalized kinetic theory:ionization density dependence. • Kinetic theory:creation of defects:track structure theory

  16. Determination of the kinetic parameters of BeO thermoluminescent samples using different methods

    Energy Technology Data Exchange (ETDEWEB)

    Algarve, Fábio J.; Caldas, Linda V.E., E-mail: fjalgarve@ipen.br, E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    The objective of this work was to determine the kinetic parameters of BeO thermoluminescent (TL) samples. The knowledge of the kinetic parameters is important for the general description of the physical characteristics of a thermoluminescent material. Using a linear heating rate of 5K/s{sup -1}, the BeO peak temperatures obtained were (474.7 ± 1.2) K and (620.5 ± 1.2) K, respectively, for the first and second TL peaks. The peak shape and the glow curve area measurement methods and the Urbach formula have been used for the trap parameter determination. A kinetic order of about two was determined for the first peak, whereas the second peak followed the first-order kinetics according to the geometrical factor. The energy activation values obtained using different kinds of measurements are in good agreement, including the Kitis method for deconvolution of the glow curve. Furthermore the results agree with those presented by other authors. (author)

  17. Fit of second order thermoluminescence glow peaks using the logistic distribution function

    International Nuclear Information System (INIS)

    Pagonis, V.; Kitis, G.

    2001-01-01

    A new thermoluminescence glow curve deconvolution (GCD) function is introduced which accurately describes second order thermoluminescence (TL) curves. The logistic asymmetric (LA) statistical probability function is used with the function variables being the maximum peak intensity (I m ), the temperature of the maximum peak intensity (T m ) and the LA width parameter a 2 . An analytical expression is derived from which the activation energy E can be calculated as a function of T m and the LA width parameter a 2 with an accuracy of 2% or better. The accuracy of the fit was tested for E values ranging from 0.7 to 2.5 eV, for s values between 10 5 and 10 25 s -1 , and for trap occupation number n 0 /N between 1 and 10 -6 . The goodness of fit of the logistic asymmetric function is described by the Figure of Merit (FOM) which is found to be of the order of 10 -2 . Preliminary results show that the GCD described here can easily be extended to the description of general order TL glow curves by varying the asymmetry parameter of the logistic asymmetric function. It is concluded that the TL kinetic analysis of first, second and general order TL glow curves can be performed with high accuracy and speed by using commercially available statistical packages that incorporate the Weibull and logistic asymmetric functions. (author)

  18. Crystal growth and thermoluminescence response of NaZr2(PO4)3 at high gamma radiation doses

    International Nuclear Information System (INIS)

    Ordóñez-Regil, E.; Contreras-Ramírez, A.; Fernández-Valverde, S.M.; González-Martínez, P.R.; Carrasco-Ábrego, H.

    2013-01-01

    Graphical abstract: -- Highlights: •NaZr 2 (PO 4 ) 3 exposed to gamma doses of 10, 30 and 50 MGy. •Gamma radiation produced growth of the crystal size of the NZP. •Morphology changes were reversible by heating. •Linear relationship between the thermoluminescence and the applied gamma dose. •This property could be useful for high-level gamma dosimetry. -- Abstract: This work describes the synthesis and characterization of NaZr 2 (PO 4 ) 3 . The stability of this material under high doses of gamma radiation was investigated in the range of 10–50 MGy. Samples of unaltered and gamma irradiated NaZr 2 (PO 4 ) 3 were characterized by X-ray diffraction, infrared spectroscopy, scanning electron microscopy, energy dispersive X-ray spectroscopy, and thermoluminescence. The results showed that while functional groups were not affected by the gamma irradiation, morphology changes were observed with increasing doses of gamma irradiation. The morphology of the non-irradiated compound is agglomerated flakes; however, irradiation at 10 MGy splits the flakes inducing the formation of well-defined cubes. Gamma irradiation induced the crystal size of the NaZr 2 (PO 4 ) 3 to grow. The heat treatment (973 K) of samples irradiated at 50 MGy resulted in the recovery of the original morphology. Furthermore, the thermoluminescence analysis of the irradiated compound is reported

  19. Storing of free neutrons

    International Nuclear Information System (INIS)

    Trinks, U.

    1978-12-01

    The applied method makes use of the interaction between the magnetic moment μ vector of the neutron and a magnetic field B vector. By means of superconducting magnets there can easily be achieved potential walls of μ B approximately 2 x 10 -7 eV. The principle of magnetic storing was first used for the storage ring NESTOR and showed immediate success: the stored neutrons decreased exponentially with a time constant tau = (907 +- 70) sec corresponding to the natural lifetime of the neutrons within the statistical errors. This means that there occurred no measurable additional losses (e.g. by resonance excitation) Neutrons therefore could be observed in the storage ring during about 5 half-lives (in principle of course longer, too). The orbit dynamics for neutrons in the storage ring is smilar to that in circular accelerators for charged particles. It is so well understood that the problem of the storage ring for uncharged particles (with magnetic moment) may be considered to e solved. (orig./HSI) [de

  20. Accelerating and storing polarized hadron beams

    International Nuclear Information System (INIS)

    Teng, L.C.

    1990-10-01

    Polarization hadron experiments at high energies continue to generate surprises. Many questions remain unanswered or unanswerable within the frame work of QCD. These include such basic questions as to why at high energies the polarization analyzing power in pp elastic scattering remains high, why hyperons are produced with high polarizations etc. It is, therefore, interesting to investigate the possibilities of accelerating and storing polarized beams in high energy colliders. On the technical side the recent understanding and confirmation of the actions of partial and multiple Siberian snakes made it possible to contemplate accelerating and storing polarized hadron beams to multi-TeV energies. In this paper, we will examine the equipment, the operation and the procedure required to obtain colliding beams of polarized protons at TeV energies

  1. Thermoluminescent coactivated rare earth oxyhalide phosphors and x-ray image converters utilizing said phosphors

    International Nuclear Information System (INIS)

    Rabatin, J.G.

    1984-01-01

    Oxyhalides of lanthanum, gadolinium and lutetium coactivated with a first activator selected from bismuth and samarium to provide the color of light emission and a second coactivator (e.g. terbium or praseodymium) which increases the amount of stored energy in a stored radiographic latent image are found to be superior in their conversion efficiency of x-rays to visible light. (author)

  2. Store manager performance and satisfaction: effects on store employee performance and satisfaction, store customer satisfaction, and store customer spending growth.

    Science.gov (United States)

    Netemeyer, Richard G; Maxham, James G; Lichtenstein, Donald R

    2010-05-01

    Based on emotional contagion theory and the value-profit chain literatures, the present study posits a number of hypotheses that show how managers in the small store, small number of employees retail context may affect store employees, customers, and potentially store performance. With data from 306 store managers, 1,615 store customer-contact employees, and 57,656 customers of a single retail chain, the authors examined relationships among store manager job satisfaction and job performance, store customer-contact employee job satisfaction and job performance, customer satisfaction with the retailer, and a customer-spending-based store performance metric (customer spending growth over a 2-year period). Via path analysis, several hypothesized direct and interaction relations among these constructs are supported. The results suggest implications for academic researchers and retail managers. PsycINFO Database Record (c) 2010 APA, all rights reserved.

  3. Shopping in discount stores

    DEFF Research Database (Denmark)

    Zielke, Stephan

    2014-01-01

    quarters of intentions to shop in discount stores. Value perception has the strongest total effect, which is partly mediated by enjoyment, shame and guilt. Attributions influence the shopping intention indirectly via value perception and emotions. The inferior quality attribution has the strongest total......This paper analyzes the impact of price-related attributions, emotions and value perception on the intention to shop at grocery discounters in an integrated framework. Moderating effects of price consciousness are also analyzed. The results show that the proposed model explains almost three...... effect, followed by the efficiency of the business model attribution. The unfairness to stakeholders and the tricks in price communication attribution mostly influence the shopping intention for less price-conscious customers....

  4. Re-use of radio-thermoluminescent LiF without regeneration; Reemploi sans regeneration du LiF radiothermoluminescent

    Energy Technology Data Exchange (ETDEWEB)

    Portal, G; Francois, H; Blanchard, Ph [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-07-01

    There is at the present time a rapid development of dosimetry techniques using thermoluminescence. Amongst the many substance actually in use, research laboratories generally employ lithium fluoride which is of particular interest for dosing {beta} radiation and low-energy X and {gamma} radiation. It might also be of use in radioprotection if its practical application were simpler. It has in effect unstable traps situated just below the surface which adversely affect the measurements if the material is not regenerated before each operation; this process considerably complicates the carrying out of measurements in the field of radioprotection. We have prepared a lithium fluoride giving unstable peaks which are less pronounced that those of the commercially available product and which can therefore be used without regeneration. In this report we compare the thermoluminescence curves for these two products. An analysis is given of the reasons for which this radio-thermoluminescent product has a stable luminescence curve and can be used almost one hundred times without being regenerated. We show that this quality can be retained when the LiF is used as a filler for teflon for applications in detectors. (authors) [French] On assiste a un developpement rapide des techniques de dosimetrie par thermoluminescence. Parmi les nombreux materiaux actuellement utilises, les laboratoires de recherche font generalement porter leur preference sur le fluorure de lithium qui est particulierement interessant pour la dosimetrie des rayonnements {beta} et des rayonnements X et {gamma} de faible energie. Ses qualites seraient egalement appreciees en radioprotection si sa mise en oeuvre etait plus simple. Il presente en effet des pieges instables situes a une faible profondeur qui alterent les mesures si l'on ne procede pas, avant chaque utilisation, a la regeneration du materiau, operation qui alourdit considerablement les mesures pratiquees en radioprotection. Nous avons prepare un

  5. Walmart Experimental Store Performance Stories: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Deru, M.; Kozubal, E.; Norton, P.

    2010-08-01

    Walmart opened two experimental stores--one in Colorado and one in Texas--in 2005 to serve as test beds for several advanced building systems. Each embodied more than 50 experiments covering materials, water systems, energy systems, and renewable energy production. Walmart worked for three years with the National Renewable Energy Laboratory for the Colorado Store and Oak Ridge National Laboratory for the Texas store to monitor, analyze, and report on their performance. HVAC experiments included waste oil boilers, a microturbine/absorption chiller combined heat and power system, evaporative cooling, and a transpired solar collector. The refrigeration systems integrated a medium-temperature secondary loop, evaporatively cooled condenser, doors on medium-temperature cases, and light-emitting diodes on cases. Experiments in the lighting systems included a redesigned roof for clerestory daylighting and T-5 fluorescent lamps. Three photovoltaic systems for a total of 135 kW and a 50-kW wind turbine are also included. The energy system performance was compared to the measured performance of a prototypical Walmart store and to other benchmarks.

  6. Thermoluminescence dating. Application to the chronology of volcanic ashes

    International Nuclear Information System (INIS)

    Pilleyre, T.

    1991-09-01

    Thermoluminescent (TL) dating is generally used for minerals heated in the past and can be used for absolute chronology of volcanic ashes but seems limited to less than 15.000 years. The aim of the thesis is the study of thermoluminescent properties of quartz for high doses and long irradiations using the red TL peak of quartz which is situated at high temperature (about 370 deg. C) to extend the method for higher ages. A theory, based on spatial correlation between electron and hole created during the same ionization, is developed. A chapter is devoted to dosimetry because of its importance in TL dating, especially alpha scintillation counting and the influence of humidity on the determination of annual dose. Volcanic samples are dated from 10.000 to 80.000 years before present

  7. Study on carbonated hydroxyapatite as a thermoluminescence dosimeter

    International Nuclear Information System (INIS)

    Shafaei, M.; Sardari, D.; Ziaie, F.; Larijani, M.M.

    2015-01-01

    In this study, carbonated hydroxyapatite nanoparticles were used for thermoluminescence dosimetry. The nano-structure carbonated hydroxyapatite synthesized via hydrolysis of CaHPO 4 and CaCO 3 . The obtained nano powders were characterized by XRD technique and FTIR spectroscopy system. The carbonated hydroxyapatite samples were irradiated at different doses using 60 Co gamma rays, and were subjected to thermoluminescence measurement system, consequently. The TL glow curve exhibited two distinguishable peaks centered at around of 165 C and 310 C. The TL response of carbonated hydroxyapatite samples as a function of absorbed dose was linear in the range of 25-1000 Gy. Other dosimetric features of the carbonated hydroxyapatite nanoparticles including fading and reproducibility were also investigated.

  8. Thermoluminescence authentication of T'ang and Han Dynasty pottery

    International Nuclear Information System (INIS)

    Price, D.M.

    1997-01-01

    More than 80 pieces of T'ang Dynasty and 40 Han Dynasty style ceramic wares have been analysed to determine the amount of thermoluminescence (TL) accumulated since the initial firing of the object and the level of the radiation flux which has created the TL. This paper presents a summary of the thermoluminescence analysis results. Approximately 60% of Han ceramics and 45% of the T'ang pottery authenticated have been shown to belong to periods other than that stylistically suggested. Items which have been found not to be of the anticipated antiquity generally fall into distinct age groups. Of the T'ang wares the most commonly copied item is found to be the horse and for the Han pieces, human figures and ewers/pots/vases represent the most frequently reproduced wares

  9. Statistical methods to evaluate thermoluminescence ionizing radiation dosimetry data

    International Nuclear Information System (INIS)

    Segre, Nadia; Matoso, Erika; Fagundes, Rosane Correa

    2011-01-01

    Ionizing radiation levels, evaluated through the exposure of CaF 2 :Dy thermoluminescence dosimeters (TLD- 200), have been monitored at Centro Experimental Aramar (CEA), located at Ipero in Sao Paulo state, Brazil, since 1991 resulting in a large amount of measurements until 2009 (more than 2,000). The data amount associated with measurements dispersion, since every process has deviation, reinforces the utilization of statistical tools to evaluate the results, procedure also imposed by the Brazilian Standard CNEN-NN-3.01/PR- 3.01-008 which regulates the radiometric environmental monitoring. Thermoluminescence ionizing radiation dosimetry data are statistically compared in order to evaluate potential CEA's activities environmental impact. The statistical tools discussed in this work are box plots, control charts and analysis of variance. (author)

  10. Thermoluminescent dosemeter in a X-ray diffractometer

    International Nuclear Information System (INIS)

    Mendoza A, D.; Gonzalez M, P.; Falcon B, T.; Castano, V.M.

    1999-01-01

    In this work it was presented the results obtained of the dosimetry which was realized in a X-ray diffractometer for powders, trademark Siemens D5000, using the thermoluminescent signal generated by the X-rays in the commercial dosemeter TLD-100 of Harshaw, US. In according to the results obtained, the radiation quantity received by an analysed material in the diffractometer, will be proportional to exposure time and it can vary from unities until tenths of grays. These results are very outstanding when are analysed crystalline materials in a diffractometer, for knowing the present crystalline phases, mainly if these are highly sensitive to the ionizing radiation, as it is the case of the thermoluminescent materials. (Author)

  11. Combination of archaeomagnetism and thermoluminescence for precision dating

    Science.gov (United States)

    Becker, H.; Göksu, H. Y.; Regulla, D. F.

    Archaeomagnetic dating was applied to two chalk-burning ovens from an early medieval noble-cemetery. Usually this method allows dating by the investigation of the geomagnetic declination and inclination through the thermoremanent magnetisation of baked clay in situ. However, in this case the method resulted in multiple dates since it was not possible to distinguish the brainching of the geomagnetic secular variation curve. Thermoluminescence dating was applied to the same samples to overcome the problem of multiple dates. This first combined application of archaeomagnetism and thermoluminescence for dating yielded A.D. 670±30 for the two ovens, which dates the first stone-church at the site after a wooden predecessor archeologically dated A.D. 620-630.

  12. Observations on some thermoluminescence emission centres in geological quartz

    International Nuclear Information System (INIS)

    Scholefield, R.B.; Prescott, J.R.; Fox, P.J.; Franklin, A.D.

    1994-01-01

    We report measurements of three-dimensional thermoluminescence emission spectra of samples of geological quartz, derived from Australian sediments. The emphasis is on peaks of particular practical interest for thermoluminescence sediment dating, viz. the 110 o C peak, which is used for pre-dose dating and the peak at 325 o C, which is of significance for partial and selective bleach techniques and for optically stimulated luminescence (OSL) dating. Because the 325 o C peak can be bleached to essentially zero, it can be isolated in a given spectrum by subtracting the bleached spectrum from the unbleached spectrum. By including both peaks in the same spectrum, it is demonstrated that they do not emit at the same wavelength, although this does not necessarily mean that the emission is from different emission centres. The 375 o C peak, which is important in total bleach methods, emits at a distinguishable wavelength. The use of bleaching and subtraction in practical dating is discussed. (Author)

  13. Preliminary research on thermoluminescence application in complicated geological situation

    International Nuclear Information System (INIS)

    Gong Gelian; Liu Chunsheng

    2003-01-01

    Thermoluminescent phenomenon resulting from two kinds of complicated geological situation, Ordos Basin and Huainan deposits in Anhui Province, is studied by the means of thermoluminescence counting method. It is shown that: (1) there are no apparent abnormalities of natural TL detected from the rock samples selected in the first 1000 meter depth of the Earth, and these natural TL are accumulated through natural radiation effects; (2) the natural TL shows statistically obvious reducing trends for the rock samples selected under the 2000 meter depth, and even no detectable TL is found for those rocks selected at 4000 meter depth. (3) the natural TL peaks corresponding to high temperature generally shift to the direction of higher temperature for the quartz-related rock samples, and several thermal events which occurred during the geological times might be responsible for this case

  14. Thermoluminescence of sulfated zircon exposed to gamma radiation

    International Nuclear Information System (INIS)

    Rubio, E.; Castano, V.M.; Mendoza A, E.; Gonzalez, P.R.

    2003-01-01

    In this work, the thermoluminescent (Tl) signal induced by gamma radiation in zirconia and sulfated zirconia samples embedded in Ptfe pellets is reported and discussed. In this case, samples were obtained through sol-gel method using zirconium n-propoxide and H 2 SO 4 as precursors, and later were subjected to thermal treatment at 600 C to obtain, the tetragonal phase accordingly to X-ray diffraction analysis. Experimental results show that the thermoluminescent glow peak depends on both, the crystalline structure and sulfate concentration. Two maximum peaks were observed located at 147 C and 274 C arising from the electronic transitions. Tl response as a function of the absorbed dose shows a linear increase for a wide of range exposure as well as good stability in time. The high sensitivity, dose linearity and signal stability of this material open the potential possibility to be used for the dosimetry applications. (Author)

  15. Radio-thermoluminescence of p-InP crystals

    International Nuclear Information System (INIS)

    Aliyev, M.I.; Rashidova, Sh.Sh.; Guseynova, M.A.; Aliyev, I.M.

    2004-01-01

    Full text: A 3 B 5 compounds, including InP, are called forth the heighten interest in connection with their use in such devices as bipolar and field transistors with hetero junctions, solar cells, light emitting diodes, etc. It is known that under influence of high-level radiation (gamma quanta electron, etc. bombardment ) in semiconductors there are formed either local energetic defect states of torn bonds in the case of the crystal radiation with gamma quanta or local energy level tails of gap states at the expense of the point defect formation and that leads to the change of electrophysical and optical properties of A 3 B 5 compounds. In the paper, it is put forward results of experimental investigations of radio-thermoluminescence (RTL) features of gamma irradiated p-InP crystals in the range of 80 to 400 K. Samples doped with InP were fabricated by the Czochralski method. p-In crystals were irradiated with gamma quanta by the isotopic source, 60 Co, with the dose power of D=1.03 Gy/s at temperature of 77 K. Curves for RTL were obtained by a radio-thermo-luminograph, RTL-69, while the heating rate was 5 K/min. Presents the dependence of RTL versus temperature after each stage of radiation with doses of D=10 kGy and D=35 kGy. It is shown, that with increasing the radiation dose the intensity of luminescence decreases. It is also observed a shift of the maximum peak at 180 K towards lower temperatures by 10 degrees. The peak after irradiation with the large dose (D=35 kGy) is manifested at 170 K. The peak being emerged after irradiation with the dose of D=35 kGy at 300 K correspondents the H 3 (0.51 eV) level, which is the P In 0 hole trap. The decrease of the peak intensity after irradiation with the high dose is apparently connected with radiation anti-structural defects (ASD) of the donor type, In P . Thus, the irradiation by gamma quanta of InP crystals, doped with Zn results in the point defect formation of the structure, i.e. defects of the ASD

  16. Archaeological and Geological dating by means of thermoluminescence

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.

    1999-01-01

    In this thesis an specific method for dating local archaeological and geological samples based on the phenomenon of thermoluminescence (TL) using the fine grain and quartz inclusion techniques is developed. Taking into account that this work is interesting for professionals working in the fields of Physics, Chemistry, Archaeology, Anthropology and related sciences, some basic concepts are described to have a better comprehension. Chapter 1 describes the concept of radioactivity, remarking the importance of the different decay types as well as the main radioactive series and the energy liberated in the process. The causes of radioactive desequilibrium are also considered in the case for radon. Another important aspect taken into account in this chapter is the radioisotope production and its relationship with the neutron activation analysis used for the determination of the Uranium and Thorium concentrations in the samples. The TL phenomenon is described in Chapter 2, emphasizing the importance of the process of thermally stimulated luminescence best known as TL and its application for dating minerals of different origin. Chapter 3 shows some important antecedents remarking some aspects of the techniques commonly used for dating purposes. Chapter 4 shows the different methods used for the sample preparation. The techniques used for the 40 K, 238 U and 232 Th determination as well as for the cosmic radiation measurement using locally made TLD are also described. The methods used for the determination of the paleodosis as a function of the TL intensity of each sample are described: special emphasis is taken on the moisture effects as well as in the error limits in the age estimation. Results and conclusions of this study are presented in Chapter 5. These results gave an age of 980 ± 90 years for the Edzna ceramic and 1520 ± 90 years for the Calixtlahuaca ceramics. The age of the Teotihuacan ceramics was not estimated due to the lack of a stable region of the traps

  17. The importance of store windows in creating store identity and store attractiveness

    Directory of Open Access Journals (Sweden)

    Renko Sanda

    2012-01-01

    Full Text Available While choosing the store, customer first notices the store window and it plays an important role in retailing strategy. Store's window is what customers see first in meeting with the store. Store window design can lead customer to enter the store, and can give a lot of information about store brands and products. Besides the analysis of the way how specific elements of the window design affect customers and their perception, the explanation of their attraction and rejection to customers is given. If we consider the importance of the topics, we can point out the lack of literature about store windows as the communication tool which allow store to communicate with its customers and to create its retailing strategy as well. There is the scientific contribution of this paper. The paper gives theoretical comprehensions completed with the results of the study about the importance of store windows for retailers as well as for customers. Therefore, for the purpose of this paper, a two-phase research study, including a qualitative and a quantitative approach, was used: 1 the qualitative study among retailers which indicated the most important elements of store windows, the level of financial sources invested in the window design, the basis for the decisions about store window design, etc.; 2 the quantitative study on the sample of consumers conducted with on-line questionnaire. Findings suggest that store window attractiveness is the main motif for store visits. The results of the research confirm that by means of store window and its elements (with special emphasis on price and pricing actions retail store sends messages to its consumers.

  18. Suitability of the thermoluminescence method for detection of irradiated foods

    International Nuclear Information System (INIS)

    Pinnioja, S.

    1993-01-01

    Irradiated foods can be detected by thermoluminescence (TL) of contaminating minerals. Altogether about 300 lots of herbs, spices, berries, mushrooms and seafood were studied by the TL method. Irradiated herbs and spices were easily differentiated from unirradiated ones two years after irradiation of a 10 kGy dose. The mineral composition of seafood was variable; and while calcite was suitable for the TL analysis, aragonite and smectite gave unreliable results. Control analyses during two years confirmed the reliability of TL method. (author)

  19. An optical fibre-type silicate glass thermoluminescent detector

    International Nuclear Information System (INIS)

    Zheng Zheng; Dai Honggui; Hu Shangze; Liu Jian; Fang Jie

    1991-01-01

    A description of dosimetric properties and the preparation method of an optical fibre-type silicate glass thermoluminescent detector (TLD) is presented. Results showed that this new phosphor is a good one which could be used as a routine dosimeter in the range 10 -1 -10 3 Gy. The preparation method is a new one which differs greatly from all previous ones. Furthermore this kind of detector is small and of low weight. (orig.)

  20. Confrontation of thermoluminescence models in lithium fluoride with experimental data

    International Nuclear Information System (INIS)

    Niewiadomski, T.

    1976-12-01

    The thermoluminescent properties of lithium fluoride depend on numerous factors and are much more complex than those of other phosphors. The so far developed fragmentary models are meant to explain the relationships between crystal defect structure and the processes involved in TL. An attempt has been made to compare these models with the veryfied experimental data and to point out the observations which are inconsistant with the models. (author)

  1. Preparation of lithium fluoride for thermoluminescent detectors of ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Mironenko, S.N.; Nepomnyashchikh, A.I.; Ikrami, D.D.; Paramzin, A.S.; Rakhimov, M.Eh.

    1985-03-01

    The thermostimulated luminescence (TSL) of lithium fluoride monocrystals depending on the method of preparation of starting raw material and features of its preliminary processing is investigated. It is shown that only lithium fluoride of high purity prepared through the stage of formation of hydrofluoride and its subsequent decomposition can be used without any additional processing for manufacturing monocrystal detectors of thermoluminescent dosimetry of the ionizing radiation with low intensity of low temperature peaks.

  2. A thermoluminescence study of vempalle dolomites and its depositional environments

    International Nuclear Information System (INIS)

    Bhattacharya, A.K.; Rao, C.N.; Kaul, I.K.

    1976-01-01

    An attempt has been made to interpret the depositional environment of Vempalle dolomites (India) by thermoluminescence method. It has been demonstrated that glow curve patterns reflect the environmental condition of deposition for carbonate sediments. The glow curves were obtained for natural samples as well as samples irradiated by Co 60 and compared. A majority of the samples were concluded to be diagenetic. (A.K.)

  3. Thermoluminescence sensitivity variations in LiF PTFE dosemeters incurred by improper handling procedures

    CERN Document Server

    Mason, E W; MacKinlay, Alistair F; Saunders, D

    1975-01-01

    A systematic study of some anomalous darkening effects and thermoluminescence sensitivity variations observed in LiF:PTFE thermoluminescent dosemeters is described. Various likely causes of such effects have been investigated. The manufacturer's recommended cleaning procedures have been found to be inadequate and, in some cases, have been found to actually promote discolouration of the dosemeters. Recommendations are given for the successful use of LiF:PTFE thermoluminescent dosemeters in personal dosimetry.

  4. Thermoluminescence of LiF: Mg, Ti between 77 and 315 K

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da.

    1989-01-01

    A special thermoluminescent system was developed. It is able to operate right from liquid nitrogen temperature and also permits the determination of the sample thermoluminescent emission spectrum. Using this system, the thermoluminescence displayed by 77 K irradiated LiF:Mg,Ti (TLD-100), from the irradiation temperature to 315 K, was studied. In this temperature range seven glow peaks, at 139, 153, 194, 240, 260, 283 and 300 K, were determined. (author)

  5. Food irradiation dosimetry using thermoluminescence of quartz sand

    International Nuclear Information System (INIS)

    Khan, H.M.; Ehlermann, D.A.E.

    1993-01-01

    Thermoluminescence of quartz sand, which is inert and concomitant to several food materials, has been investigated for applications in food irradiation dosimetry and detection of irradiated foods. The glow curves consist of at least three overlapping peaks from 100 to 420 C. The peak at lower temperature is not stable and decays quickly at room temperature. However, the peaks at higher temperature are stable and more useful for dosimetry work. The intensity of the peak at 360 C, measured using different optical filters, shows a linear response in the range of 0.05 to 23 kGy. Stability of these signals at different annealing temperatures has been investigated. Thermoluminescence from adhering minerals and contaminating dust in different food materials has been found useful for the detection of irradiation treatment. Since quartz is frequently one of these minerals, further computerized deconvolution of individual glow peaks from the complex glow curves of quartz sand was carried out which improves the dosimetric results. Possible applications of thermoluminescence of quartz sand in food irradiation dosimetry and detection of irradiated foods have been discussed. (orig.)

  6. Thermoluminescence kinetics of pyrite (FeS2)

    International Nuclear Information System (INIS)

    Silverman, A.N; Levy, P.W.; Kierstead, J.A.

    1990-01-01

    Thermoluminescence of pyrite (FeS 2 ) has been investigated to study the kinetics of single peak glow curves. The material used normally exhibits one large and four small peaks. However a glow curve can be obtained with only the large single peak that is suitable for testing thermoluminescence kinetics. Glow curves from aliquots of a single natural pyrite crystal studied in detail contain two low intensity thermoluminescence (TL) peaks at ∼90 degree and ∼250 degree C, and two chemiluminescence (CL) peaks at ∼350 degree and ∼430 degree C. The CL peaks are largely removable by initially heating the sample chamber under vacuum, pumping through liquid nitrogen traps, and recording glow curves immediately after helium is introduced, procedures which reduce system contaminants that react with pyrite. The shape, the variation of the temperature of the peak maximum (T max ) with dose, and the retrapping to recombination cross section ratio σ of the large 250 degree C peak are better described by the general one trap (GOT) kinetic equation, the basic equation from which the 1st and 2nd order kinetic equations are obtained as special cases (see text), than by the 1st and 2nd order equations. 12 refs., 7 figs

  7. Detection of irradiated food: Thermoluminescence analysis of spices, herbs, and spice-and-herb products. Thermolumineszenz-Analyse an Gewuerzen, Kraeutern und Gewuerz- und Kraeutermischungen

    Energy Technology Data Exchange (ETDEWEB)

    Schreiber, G A [Fachgebiet Lebensmittelbestrahlung, Bundesgesundheitsamt, Berlin (Germany); Helle, N [Fachgebietsgruppe Lebensmittel- und Arzneimittelbestrahlung, Bundesgesundheitsamt, Berlin (Germany); Boegl, K W

    1993-09-01

    About 3 and 9 months after irradiation 14 laboratories determined the thermoluminescence (TL) of mineral contaminations which were isolated from different coded spice-and-herb products. In both study periods 99% of the 317 samples (total number) were correctly identified as irradiated or non-irradiated on the basis of normalized TL intensities. Only three irradiated samples were not identified as irradiated. The results show that irradiation of spices, herbs and spice-and-herb mixtures can be clearly detected throughout the entire period in which the products are normally stored, and that the method is suitable for routine analysis in food control laboratories. (orig.)

  8. Variation in thermoluminescence of irradiated brands of foodstuffs: a test for hygienic quality

    International Nuclear Information System (INIS)

    Mamoon, A.; Zaheer, A.; Abu-Abdullah, S.

    1996-01-01

    Thermoluminescence of irradiated foodstuffs such as herbs and spices, is mostly due to attached dust or soil particles. Different brands of the same foodstuff sometimes give thermoluminescent signals of different intensities, apparently due to different degrees of dust contamination. It is of obvious importance to choose brands of foodstuffs that appear to have less dust contamination, i.e. of better hygienic quality. Several food items were investigated with respect to their thermoluminescent (TL) emission in order to assess TL usefulness as an indicator of hygienic quality for foods prone to contamination by dust. In this regard some foodstuff were artificially contaminated with a soil sample and their thermoluminescent emission was obtained. (author)

  9. A study of the high-temperature signal characteristics in the thermoluminescence of porcelain

    International Nuclear Information System (INIS)

    Yin Gongming

    2001-01-01

    The thermoluminescence pre-dose technique for dating ancient porcelain was developed in many laboratories. This technique was the only method which could directly determine the age of old porcelain. But the thermoluminescence high-temperature signal (over 200 degree C) had not been studied. The authors conduced a preliminary study of the characteristic of thermoluminescence high-temperature signal, such as the TL natural glow curve, and the glow curves after beta or alpha irradiation. Most of the 32 ancient porcelains had thermoluminescence high temperature signal, and only one peak in their TL glow curve was found

  10. Achievement report for fiscal 1998. Research and development of new technologies for storing farm products utilizing low-temperature energy (2nd fiscal year); 1998 nendo seika hokokusho. Teion energy wo riyoshita nosanbutsu no shinki chozo gijutsu no kenkyu kaihatsu (dai 2 nendo)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    The aim of the work was to create new industrial technologies utilizing low-temperature energy satisfying local needs through developing new technologies, including air conditioning technologies high in reliability and excellent in energy efficiency. The objectives of the effort were to elucidate the behavior of moisture in the atmosphere below the freezing point and to develop farm product preserving technologies, to develop highly efficient energy conversion technologies for use in the low-temperature zone, latent heat storing cold heat technologies, and system evaluation. Constructed in connection with the last-said system evaluation were three technologies, which were a below-zero high-humidity air conditioning technology based on the outcome of agricultural verification of farm product storage, energy-efficient low-temperature storage of farm products which was a combination of a low-temperature oriented energy-efficient energy conversion technology and a clathrate hydrate-aided cold heat storing technology, and a technology applicable to business in the low-temperature processing field accessorial to the said technologies. They were compared with the conventional technologies, and then it was found that the most energy-efficient system, as endorsed by a 40-50% reduction it caused in electricity rate, was a combination of a low-temperature storage, frozen food storage, hydrate cold heat storage tank, recovery facility for farm waste incineration-produced waste heat, and a pulse tube freezer. (NEDO)

  11. Tobacco advertising in retail stores.

    Science.gov (United States)

    Cummings, K M; Sciandra, R; Lawrence, J

    1991-01-01

    Recent studies have described tobacco advertising in the print media, on billboards, and through sponsorship of cultural and sporting events. However, little attention has been given to another common and unavoidable source of tobacco advertising, that which is encountered in retail stores. In July 1987, we conducted a survey of 61 packaged goods retail stores in Buffalo, NY, to assess the prevalence and type of point-of-sale tobacco advertising. In addition, store owners or managers were surveyed to determine their store's policy regarding tobacco advertising, receipt of monetary incentives from distributors for displaying tobacco ads, and willingness to display antitobacco ads. Six types of stores were involved in the study: 10 supermarkets, 10 privately owned grocery stores, 9 chain convenience food stores that do not sell gasoline, 11 chain convenience food stores that sell gasoline, 11 chain pharmacies, and 10 private pharmacies. Two-thirds of the stores displayed tobacco posters, and 87 percent had promotional items advertising tobacco products, primarily cigarettes. Larger stores, and those that were privately owned, tended to display more posters and promotional items. Eighty percent of tobacco product displays were for cigarettes, 16 percent for smokeless tobacco products, and 4 percent for cigars and pipe tobacco. Convenience stores selling gasoline had the most separate tobacco product displays. Of tobacco product displays, 24 percent were located adjacent to candy and snack displays. Twenty-nine of the 61 store owners or managers indicated that their store had a policy regulating the display of tobacco ads and tobacco product displays.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1910192

  12. The properties of CaF2:Dy used as a thermoluminescent dosimeter at low doses

    International Nuclear Information System (INIS)

    Budd, T.

    1976-05-01

    Chips of CaF 2 :Dy have been studied to assess their usefulness as a thermoluminescent dosimeter for the measurement of doses of the order of 1 mrad in water. The glow curve structure and the total light output from peaks below about 240 0 C have both been studied. Experiments have been done to study linearity, fading and energy dependence. Fading was found to be 15% in the first day and a further 21% over four weeks. The response of the material per rad in water showed a peak at 30 keV where the sensitivity was 17.5 times the value at 1 MeV. Doses of 0.1 mrad have been assessed with a standard deviation of 25%. (author)

  13. The application of an automated thermoluminescence dosimetry system to environmental γ-dosimetry

    International Nuclear Information System (INIS)

    Jones, A.R.

    1977-07-01

    A personnel monitoring system comprising thermoluminescent dosimeters (TLDs) and an automatic TLD reader has been applied to environmental gamma dosimetry. For this purpose the accuracy of measurement at low exposures (10 to 100 mR) acquired over long periods (3 or 12 months) is important. To improve the accuracy and reliability of the system for this application the following steps were taken: the dosimeters were sensitized by irradiation with γ-rays and annealed while being irradiated with UV light; the sensitivity of each, identified dosimeter was measured and used to correct exposure measurements; the gasketted holders were modified to contain TLDs mounted on two identified plaques. Measurements of linearity, variability (with and without individual calibration) fading and energy dependence are presented. (author)

  14. The measurement of dose at 70 micrometres' depth using thermoluminescent dosimeters (tlds)

    International Nuclear Information System (INIS)

    Jones, A.R.

    1989-01-01

    The measurement of dose with thermoluminescent dosimeters (TLD) at a tissue-equivalent depth of 70 μm can be done in three ways. These are by using: very thin TLDs (made by cementing fine, powdered, TLD particles to a high-temperature plastic film); opaque TLDs whose surface alone is sensitive. (Light emitted at a greater depth has a low probability of emergence and, thus, they behave as if they were thin.); at least three TLDs covered with absorbers of differing thickness. The approaches were studied using examples of dosimeter arrangements of the three types. The characteristics which were measured to form a basis of comparison were: the performance at high and low doses; the effect of changing angle of incidence and beta-ray energy; the effect on performance of repeated irradiation, annealing and reading. It was concluded that the very thin TLDs (powdered) are the best suited to the measurement of doses at 70 μm depth

  15. Thermoluminescence dosimetry properties of new Cu doped CaF(2) nanoparticles.

    Science.gov (United States)

    Zahedifar, M; Sadeghi, E

    2013-12-01

    Nanoparticles of Cu-doped calcium fluoride were synthesised by using the hydrothermal method. The structure of the prepared nanomaterial was characterised by the X-ray diffraction (XRD) pattern and energy dispersive spectrometer. The particle size of 36 nm was calculated from the XRD data. Its shape and size were also observed by scanning electron microscope. Thermoluminescence (TL) and photoluminescence of the produced phosphor were also considered. The computerised glow curve deconvolution procedure was used to identify the number of glow peaks included in the TL glow curve of the CaF2:Cu nanoparticles. The TL glow curve contains two overlapping glow peaks at ∼413 and 451 K. The TL response of this phosphor was studied for different Cu concentrations and the maximum sensitivity was found at 1 mol% of Cu impurity. Other dosimetric characteristics of the synthesised nanophosphor are also presented and discussed.

  16. Characterization of a two-component thermoluminescent albedo dosemeter according to ISO 21909

    Energy Technology Data Exchange (ETDEWEB)

    Martins, M.M., E-mail: marcelo@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN), Av. Salvador Allende s/n, CEP 22780-160, Rio de Janeiro, RJ (Brazil); Mauricio, C.L.P., E-mail: claudia@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN), Av. Salvador Allende s/n, CEP 22780-160, Rio de Janeiro, RJ (Brazil); Pereira, W.W., E-mail: walsan@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN), Av. Salvador Allende s/n, CEP 22780-160, Rio de Janeiro, RJ (Brazil); Silva, A.X. da, E-mail: ademir@con.ufrj.b [Coordenacao dos Programas de Pos-Graduacao em Engenharia, COPPE/PEN Caixa Postal 68509, CEP 21941-972, Rio de Janeiro, RJ (Brazil)

    2011-05-15

    A two-component thermoluminescent albedo neutron monitoring system was developed at Instituto de Radioprotecao e Dosimetria, Brazil. As there is no Brazilian regulation for neutron individual monitoring service, the system was tested according to the ISO 21909 standard. This standard provides performance and test requirements for determining the acceptability of personal neutron dosemeters to be used for the measurement of personal dose equivalent, H{sub p}(10), in neutron fields with energies ranging from thermal to 20 MeV. Up to 40 dosemeters were used in order to accomplish satisfactorily the requirements of some tests. Despite operational difficulties, this albedo system passed all ISO 21909 performance requirements. The results and problems throughout this characterization are discussed in this paper.

  17. Calibration of thermoluminescence skin dosemeter response to beta emitters found in Ontario Hydro nuclear power stations

    International Nuclear Information System (INIS)

    Walsh, M.L.; Agnew, D.A.; Donnelly, K.E.

    1984-01-01

    The response of the Ontario Hydro Thermoluminescence Dosimetry System to beta radiation in nuclear power station environments was evaluated. Synthetic beta spectra were constructed, based on activity samples from heat transport systems and fuelling machine contamination smears at nuclear power stations. Using these spectra and dosemeter energy response functions, an overall response factor for the skin dosemeter relative to skin dose at 7 mg.cm -2 was calculated. This calculation was done assuming three specific geometries: (1) an infinite uniformly contaminated plane source at a distance of 33 cm (50 mg.cm -2 total shielding) from the receptor; (2) an infinite cloud surrounding the receptor; (3) a point source at 33 cm. Based on these calculations, a conservative response factor of 0.7 has been chosen. This provides an equation for skin dose assignment, i.e. Skin Dose = 1.4 x Skin Dosemeter Reading when the skin dosemeter is directly calibrated in mGy(gamma). (author)

  18. Thermoluminescence and dielectric response of LiKSO{sub 4}:Gd to {gamma}-radiation

    Energy Technology Data Exchange (ETDEWEB)

    El-Kolaly, M.A.; Kassem, M.E.; Higazy, A.A.; Ismail, L.Z.; Al-Houty, L.I. [Qatar Univ., Doha (Qatar). Dept. of Physics

    1994-10-01

    The effect of {gamma}-radiation dose up to about 324 kGy on the thermoluminescence and dielectric properties of LiKSO{sub 4}:Gd was studied. All glow curves exhibited a single peak around 373 K. The activation energy of this peak was estimated to be about 0.82 eV. The variation of the TL intensity with {gamma}-dose is characterized by a maximum at 6.75 kGy. The dielectric dispersion was studied as a function of irradiation dose. In the low frequency range straight line behaviour was obtained for low dose (up to 12.3 kGy) while for higher {gamma}-dose, semicircles are obtained. The bulk conductivity was found to increase with dose up to 6.75 kGy. (author).

  19. Electrical and thermoluminescence properties of γ-irradiated La2CuO4 crystals

    Science.gov (United States)

    El-Kolaly, M. A.; Abd El-Kader, H. I.; Kassem, M. E.

    1994-12-01

    Measurements of the electrical properties of unirradiated as well as ?-irradiated La2CuO4 crystals were carried out at different temperatures in the frequency range of 0.1-100 kHz. Thermoluminescence (TL) studies were also performed on such crystals in the temperature range of 300-600K. The conductivity of the unirradiated La2CuO4 crystals were found to obey the power law frequency dependence at each measured temperature below the transition temperature (Tc = 450K). The activation energies for conduction and dielectric relaxation time have been calculated. The TL response and the dc resistance were found to increase with ?-irradiation dose up to 9-10 kGy. The results showed that the ferroelastic domain walls of La2CuO4 crystal as well as its TL traps are sensitive to ?-raditaion. This material can be used in radiation measurements in the range 225 Gy-10 kGy.

  20. Thermoluminescence of pure LiF and Lif (TLD-100) irradiated at room temperature

    International Nuclear Information System (INIS)

    Sagastibelza Chivite, F.

    1980-01-01

    The thermoluminescence of pure LiF and LiF (TLD-100) crystals irradiated at room temperature with x - or gamma-rays has been studied up to 460 degree centigree. For most of the glow peaks found the kinetics, preexponential factors and activation energies have been determined. These parameters have been obtained by means of the isothermal method. The study of the thermal annealing of the radiation induced F and Z centres has allow to show that there is a correlation among the glow peaks and the annealing stages of these centres. It is concluded that the F and Z - centres play the role of recombination centres for halogen interstitial atom thermally released from traps. Light emission occurs in this recombination. (Author) 120 refs

  1. The fast neutron response of 7LiF thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Knipe, A.D.

    1990-02-01

    A series of experiments was performed in 1982 to determine the neutron energy response of the 7 LiF thermoluminescent dosemeter (TLD) employed in European zero power fast reactor gamma-ray energy deposition studies. Preliminary results of this work were included in a 1985 International experimental data-base of TLD neutron sensitivities and provided the most consistent set of data within the 7 LiF compilation. A more detailed interpretation of these data has improved the results still further, giving a mean relative neutron to gamma efficiency of 0.118±0.005. The main objective of this re-evaluation was to establish recommended neutron energy response values to replace a 1974 data set for the analysis of in-core fast reactor measurements. This was achieved by combining the mean experimental relative efficiency of 0.118 with calculated energy dependent kerma factors. The kerma factors for the TLD were based on US National Bureau of Standards values and a composition determined by chemical analysis. Adoption of the revised neutron energy response data set produces a small increase in the measured gamma-ray energy deposition of typically 2% relative to the 1974 data. However, more importantly, the detailed analysis of the experimental response data has significantly improved confidence in the neutron corrections applied to in-core TLD gamma-ray energy deposition measurements. (author)

  2. Semi-empirical simulation of thermoluminescent response under different filter geometries

    International Nuclear Information System (INIS)

    Shammas, Gabriel Issa Jabra

    2006-01-01

    Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility, small fading and simple glow curve with peaks above 150 deg C. Calcium Sulfate Dysprosium doped (CaSO 4 :Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF 2 ). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the field, where photon radiation is unknown a priori. An interesting way do make this correction in orthogonal incidence of the radiation on the phosphor is to interject a plane leaked filter between the beam and the phosphor. In order to reduce the energetic dependence on any incidence angle, reducing the field dose measurement uncertainty too, this work presents a simulation study on spherical filter geometries. It was simulated photon irradiations with Gamma rays of 60 Co and x-rays of 33; 48 and 118 keV, on many incidence angles from zero to ninety degrees. These semi-empirical computational simulations using finite differences in three dimensions were done in spherical coordinates. The results pointed out the best filter thicknesses and widths, in order to optimize the correction on energetic dependence. (author)

  3. Thermoluminescence study of Mn doped lithium tetraborate powder and pellet samples synthesized by solution combustion synthesis

    International Nuclear Information System (INIS)

    Ozdemir, A.; Yegingil, Z.; Nur, N.; Kurt, K.; Tuken, T.; Depci, T.; Tansug, G.; Altunal, V.; Guckan, V.; Sigircik, G.; Yu, Y.; Karatasli, M.; Dolek, Y.

    2016-01-01

    In this paper, the thermoluminescence (TL) dosimetric characteristics under beta-ray, x-ray and gamma-ray excitations of powder and pellet Mn-doped lithium tetraborates (LTB) which were produced by solution combustion synthesis technique were investigated, and the results were compared with that of TLD-100 chips. The chemical composition and morphologies of the obtained LTB and Mn-doped LTB (LTB:Mn) were confirmed by X-ray diffraction (XRD), Fourier Transform Infrared (FTIR) and scanning electron microscopy (SEM) with EDX. LTB:Mn was studied using luminescence spectroscopy. In addition, the effects of sintering and annealing temperatures and times on the thermoluminescence (TL) properties of LTB:Mn were investigated. The glow curves of powder samples as well as pellet samples exposed to different beta doses exhibited a low temperature peak at about 100 °C followed by an intense principal high temperature peak at about 260 °C. The kinetic parameters (E, b, s) associated with the prominent glow peaks were estimated using T m –T stop , initial rise (IR) and computerized glow curve deconvolution (CGCD) methods. The TL response of integral TL output increased linearly with increasing the dose in the range of 0.1–10 Gy and was followed by a superlinearity up to 100 Gy both for powder and pellet samples using beta-rays. Powder and pellet LTB:Mn were irradiated to a known dose by a linear accelerator with 6 and 18 MV photon beams, 6–15 MeV electron beams and a traceable 137 Cs beam to investigate energy response. Further, TL sensitivity, fading properties and recycling effects related with beta exposure of LTB:Mn phosphor were evaluated and its relative energy response was also compared with that of TLD-100 chips. The comparison of the results showed that the obtained phosphors have good TL dose response with adequate sensitivity and linearity for the measurement of medical doses.

  4. Tobacco advertising in retail stores.

    OpenAIRE

    Cummings, K M; Sciandra, R; Lawrence, J

    1991-01-01

    Recent studies have described tobacco advertising in the print media, on billboards, and through sponsorship of cultural and sporting events. However, little attention has been given to another common and unavoidable source of tobacco advertising, that which is encountered in retail stores. In July 1987, we conducted a survey of 61 packaged goods retail stores in Buffalo, NY, to assess the prevalence and type of point-of-sale tobacco advertising. In addition, store owners or managers were sur...

  5. Unfolding neutron spectra from simulated response of thermoluminescence dosimeters inside a polyethylene sphere using GRNN neural network

    Science.gov (United States)

    Lotfalizadeh, F.; Faghihi, R.; Bahadorzadeh, B.; Sina, S.

    2017-07-01

    Neutron spectrometry using a single-sphere containing dosimeters has been developed recently, as an effective replacement for Bonner sphere spectrometry. The aim of this study is unfolding the neutron energy spectra using GRNN artificial neural network, from the response of thermoluminescence dosimeters, TLDs, located inside a polyethylene sphere. The spectrometer was simulated using MCNP5. TLD-600 and TLD-700 dosimeters were simulated at different positions in all directions. Then the GRNN was used for neutron spectra prediction, using the TLDs' readings. Comparison of spectra predicted by the network with the real spectra, show that the single-sphere dosimeter is an effective instrument in unfolding neutron spectra.

  6. Developing an optimum protocol for thermoluminescence dosimetry with gr-200 chips using Taguchi method

    International Nuclear Information System (INIS)

    Sadeghi, Maryam; Faghihi, Reza; Sina, Sedigheh

    2017-01-01

    Thermoluminescence dosimetry (TLD) is a powerful technique with wide applications in personal, environmental and clinical dosimetry. The optimum annealing, storage and reading protocols are very effective in accuracy of TLD response. The purpose of this study is to obtain an optimum protocol for GR-200; LiF: Mg, Cu, P, by optimizing the effective parameters, to increase the reliability of the TLD response using Taguchi method. Taguchi method has been used in this study for optimization of annealing, storage and reading protocols of the TLDs. A number of 108 GR-200 chips were divided into 27 groups, each containing four chips. The TLDs were exposed to three different doses, and stored, annealed and read out by different procedures as suggested by Taguchi Method. By comparing the signal-to-noise ratios the optimum dosimetry procedure was obtained. According to the results, the optimum values for annealing temperature (de.C), Annealing Time (s), Annealing to Exposure time (d), Exposure to Readout time (d), Pre-heat Temperature (de.C), Pre-heat Time (s), Heating Rate (de.C/s), Maximum Temperature of Readout (de.C), readout time (s) and Storage Temperature (de.C) are 240, 90, 1, 2, 50, 0, 15, 240, 13 and -20, respectively. Using the optimum protocol, an efficient glow curve with low residual signals can be achieved. Using optimum protocol obtained by Taguchi method, the dosimetry can be effectively performed with great accuracy. (authors)

  7. Thermoluminescence of NaF:Eu{sup 3+} phosphors exposed to beta particle irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Haro, A.R.; Cruz-Vazquez, C.; Orante-Barron, V.R. [Polymers and Materials Research Department, University of Sonora (Mexico); Bernal, R. [Physics Research Department, University of Sonora (Mexico); Kitis, G. [Nuclear Physics Laboratory, Aristotle University of Thessaloniki (Greece); Castano, V.M. [Applied Physics and Advanced Technology Center, Physics Institute, Autonomous National University of Mexico (Mexico)

    2013-02-15

    Pellet-shaped NaF:Eu{sup 3+} phosphors were synthesized by sintering. When a 5 K/s heating rate was used, the char-acteristic glow curves of beta particle irradiated samples exhibited two thermoluminescence (TL) maxima located at 401 K and 498 K, being the higher temperature max-imum the most intense. A peak located between 473 and 523 K is considered to have a position very suitable to assure good thermal stability of the stored TL, so this phosphor is attractive for radiation dosimetry. Beta particle irradiated samples displayed a TL response that increases as the radiation dose increased in the 0.08 to 42.5 Gy dose range, with a linear behavior below 10 Gy followed by a sublinear one for higher doses. Under storage after irradiation, the TL maximum at 498 K displayed a remarkable stability, and the TL fading revealed that the maximum at 401 K is not a single peak. (copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  8. Dating of pre hispanic ceramics from the archaeological zone of Zoque by thermoluminescence method; Datacion de ceramica prehispanica de la zona arqueologica Zoque por el metodo de termoluminiscencia (TL)

    Energy Technology Data Exchange (ETDEWEB)

    Valdes, J.V. [UAEM, Facultad de Quimica, 50120 Toluca, Estado de Mexico (Mexico); Gonzalez, P.R.; Mendoza, D.; Tenorio, D. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Terreros, E. [Museo Templo Mayor, INAH, Seminario No. 8, Col. Centro, 06060 Mexico D.F. (Mexico); Ramirez, A. [Instituto de Geofisica, UNAM, 04510 Mexico D.F. (Mexico)

    2007-07-01

    Full text: The dating of pre hispanic ceramics resides permitting us to located them in a certain period of the history; allows us to verify it origin. The thermoluminescence is a technique that permits us to estimate the absolute age of the archaeological samples. The present work is directed in determining the age by the method of thermoluminescence of archaeological samples of the grotto of Concubac, located in the Serrana Region of Tabasco. To determine the mineralogical composition of the samples, analysis of diffraction of X rays and Energy Dispersive X-ray Spectroscopy (EDS) have been conducted. The radiation emitted by the ground where the samples were buried and the contribution of the cosmic radiation was measured with thermoluminescent dosimeters of LiF:Mg,Cu,P+PTFE. The feasibility of dating of the studied samples is broadly disputed in function of the contents of minerals, as well as the procedure and management of the sample. (Author)

  9. Numerical analysis of thermoluminescence glow curves; Analisis numerico de las cruvas de termoluminiscencia

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Ros, J M; Delgado, A

    1989-07-01

    This report presents a method for the numerical analysis of complex thermoluminescence glow curves resolving the individual glow peak components. The method employs first order kinetics analytical expressions and is based In a Marquart-Levenberg minimization procedure. A simplified version of this method for thermoluminescence dosimetry (TLD) is also described and specifically developed to operate whit Lithium Fluoride TLD-100. (Author). 36 refs.

  10. Thermoluminescence, a method for determining the date at which a ceramic object was fired

    International Nuclear Information System (INIS)

    Sayre, E.V.

    The theory on which thermoluminescence dating of archeological ceramic objects is based and the measurement methods used are outlined. Separation of fine grain particles and quartz particles permits the determination of the thermoluminescence of each and often a more accurate age determination. The application of the method to the dating of a bronze horse from the Metropolitan Museum is described

  11. Study of some thermoluminescent phosphors for the dosimetry of ionizing radiations

    International Nuclear Information System (INIS)

    Jaafari, M.

    1983-01-01

    Thermoluminescence dosimetry techniques are reviewed and interactions radiation matter are recalled. The need for new phosphors is evidenced. Numerous phosphors are examined and calcium, strontium and barium sulfides are synthetized and deposited on glass supports. The thermoluminescence of the dosimeters obtained with these materials is analyzed [fr

  12. Relationship between thermoluminescence and X-ray induced luminescence in alkali halides

    International Nuclear Information System (INIS)

    Aguilar, M.; Lopez, F.J.; Jaque, F.

    1978-01-01

    The wavelength spectra of thermoluminescence and X-ray induced luminescence in pure and divalent cation doped alkali halides, in the temperature range LNT-RT have been studied. The more important conclusion is that the wavelength spectra in both cases are very similar. This allows a new point of view to be presented on thermoluminescence mechanisms. (author)

  13. Thermoluminescent response of LiF before variation of the heating rate

    International Nuclear Information System (INIS)

    Barrios, R.; Avila, O.

    2003-01-01

    Comparisons of glow curves of lithium fluoride dosemeters TLD-100 measured to two heating rates with the purpose of quantifying the change in the temperature of the peaks 5 and 7 for the thermoluminescent reader equipment Harshaw 4000 of the thermoluminescence laboratory of the ININ were carried out. (Author)

  14. Preparation of thermoluminescent dosimeters of LiF: Mg, Cu, P + Ptfe for environmental radiological monitoring and radiodiagnosis

    International Nuclear Information System (INIS)

    Ramirez L, A.

    1996-01-01

    The necessity of finding a thermoluminescent material for measuring gamma and X radiation in applications like environmental monitoring, personnel dosimetry and biomedical sciences (radiotherapy and radiodiagnosis), but with special characteristics such as low umbral detection, independence of the energy of radiation and equivalency with the tissue. This made us think in lithium fluoride activated with magnesium, copper and phosphorous (LiF: Mg, Cu, P). In this thesis I developed this material chips like shape embedded in polytetrafluoroethylene (LiF: Mg, Cu, P+Ptfe). The chapter 1 and 2 talk about the atom is conformed and the interaction of the radiation with the matter. The requirements of Tl material, types of dosimetry system, biological effects and units of measurements are discussed in chapter 3 as well as the recommended limits of the International Commission on Radiological Protection ICRP. Chapter 4 shows aspects of the thermoluminescence phenomenon and describes, at the same time, the determination of the most important thermoluminescent parameters (kinetic order, energy or trap depth and the frequency factor). Chapter 5 describes the major characteristics and properties of Tl materials and its requirements for dosimetric use. Chapter 6 deals with the preparations of LiF: Mg, Cu, P+Ptfe chips and some tests for improving its sensitivity, describes the dosimetric tests and requirements proposed by American National Standard Institute ANSI-N545 Like: umbral of detection, homogeneity, fading, repeatability, linearity, effects of UV and fluorescent light etc. Finally in chapter 7 I do a report about analysis of results, conclusions and some recommendations. (Author)

  15. Dorte Nors "Den store tomat"

    DEFF Research Database (Denmark)

    Michelsen, Jimmi

    2017-01-01

    Tekstgennemgang og undervisningsforløb til Dorte Nors "Den store tomat". Undervisningsforløbet er henvendt til elever i folkeskolens udskoling......Tekstgennemgang og undervisningsforløb til Dorte Nors "Den store tomat". Undervisningsforløbet er henvendt til elever i folkeskolens udskoling...

  16. Consumers’ preferences regarding department stores

    NARCIS (Netherlands)

    van Laarhoven, W.; Borgers, A.W.J.; van den Berg, P.E.W.

    2017-01-01

    The main reason for this research was the bankruptcy of one the Dutch oldest and largest chain of department stores at the end of 2015. The main goal of this research is to find what, from a consumers’ perspective, a department store should look like. A four storey (1500 m2 each) building was

  17. Forhastet regulering af de store

    DEFF Research Database (Denmark)

    Thomsen, Steen

    2013-01-01

    Christiansborg gennemfører sandsynligvis en markant skærpet regulering af de store finansielle virksomheder. Det vil virke kontraktivt og medvirke til erhvervslivets kredittørke.......Christiansborg gennemfører sandsynligvis en markant skærpet regulering af de store finansielle virksomheder. Det vil virke kontraktivt og medvirke til erhvervslivets kredittørke....

  18. Thermoluminescent characteristics of oregano and paprika

    Energy Technology Data Exchange (ETDEWEB)

    Cruz Z, E.; Furetta, C.; Teuffer Z, C. [ICN-UNAM, A.P. 70-543, 04510 Mexico D.F. (Mexico); Melendrez, R.; Barboza F, M. [Universidad de Sonora, A.P. 5-88, Hermosillo, Sonora (Mexico); Kitis, G. [Nuclear Physics Laboratory, Aristotle University of Thessaloniki, 54006 Thessaloniki (Greece)

    2005-07-01

    The poly minerals from oregano and paprika were selected according to different sizes, i.e 10, 53, 74, 149 {mu}m, and they were exposed to ionizing gamma radiation in the range of doses 0.5-45 kGy. The glow curves from these spices show an abroad TL band, centered around 150 C and by XRD analysis shows a mono mineral composition mainly quartz and feldspar, including albite, ortose and clay. The fading behavior was related to the quartz, feldspar and calcite TL properties and shown the stability of the traps associated to the defects generated by irradiation in the samples. The tendency of the TL integrated was increased with the grain size for oregano and can be related to the different energy values associated to the activation energy of the traps in the monominerals. The glow curve TL from poly minerals was analyzed and it is possible to use the dosimetric property of the poly minerals from spices for detect irradiated foodstuffs. (Author)

  19. Thermoluminescent characteristics of oregano and paprika

    International Nuclear Information System (INIS)

    Cruz Z, E.; Furetta, C.; Teuffer Z, C.; Melendrez, R.; Barboza F, M.; Kitis, G.

    2005-01-01

    The poly minerals from oregano and paprika were selected according to different sizes, i.e 10, 53, 74, 149 μm, and they were exposed to ionizing gamma radiation in the range of doses 0.5-45 kGy. The glow curves from these spices show an abroad TL band, centered around 150 C and by XRD analysis shows a mono mineral composition mainly quartz and feldspar, including albite, ortose and clay. The fading behavior was related to the quartz, feldspar and calcite TL properties and shown the stability of the traps associated to the defects generated by irradiation in the samples. The tendency of the TL integrated was increased with the grain size for oregano and can be related to the different energy values associated to the activation energy of the traps in the monominerals. The glow curve TL from poly minerals was analyzed and it is possible to use the dosimetric property of the poly minerals from spices for detect irradiated foodstuffs. (Author)

  20. Thermoluminescent dosimetric properties of CaF{sub 2}:Tm produced by combustion synthesis

    Energy Technology Data Exchange (ETDEWEB)

    Vasconcelos, D.A.A. de; Khoury, H.J.; Asfora, V.K.; Barros, V.S.M. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Oliveira, R.A.P. [Universidade Federal do Vale do Sao Francisco (IPCM/UNIVASF), Juazeiro, BA (Brazil). Instituto de Pesquisa em Ciencias dos Materiais. Departamento de Energia Nuclear

    2015-07-01

    Calcium Fluoride is one of the oldest known thermoluminescent materials and is considered to be one of the most sensitive. In particular for thulium doped CaF{sub 2}, since it was introduced in 1977 by Lucas and Kapsar, besides gamma radiation dosimetry, there have been several attempts for its use in application involving mixed radiation fields (ex.: neutron and gamma; alpha and beta), low energy photons, π- dosimetry and neutrino detection. Research for novel improved methods of fabrication are ongoing. This work presents the dosimetric properties results of CaF{sub 2}:Tm produced by combustion synthesis. The X-ray diffraction (Brucker D2 Phaser) confirmed that CaF{sub 2} was successfully produced. Samples were irradiated in a Co-60 (Gammacell 220 Nordion) and Cs-137 (STS/OB-85) gamma sources for high and low doses, respectively. TL emission spectra, obtained using a Hammamatsu optical spectrometer, has the same lines of commercial CaF{sub 2}:Tm, although transitions {sup 3}P{sub 0} → {sup 3}F{sub 4} (455 nm) and {sup 1}G{sub 4}→ {sup 3}H{sub 6} (482 nm) are shown to be proportionally more intense. The dose response lower limit is in the range of 100 μGy. Thermoluminescence glow curves were obtained in a Harshaw 3500 TL reader. The deconvolution technique was employed and seven glow peaks were found as well as its kinetic parameters, similar to the commercial CaF{sub 2}:Tm. A linear dose response curve was obtained for the range 0.1 mGy to 50 Gy, with the onset of a supralinear behavior at 50 Gy up to 100 Gy. The minimum measurable dose for gamma (Cs- 137) was around 100 μGy for a 6.0 mm diameter by 1.0 mm in thickness pellet. Variation of the dose response due to fading was within 6% in 60 days. (author)

  1. Thermoluminescence response of the poly mineral fraction from hibiscus sabdariffa L foodstuffs

    International Nuclear Information System (INIS)

    Cruz Z, E.; Guzman, S.; Brown, F.; Chernov, V.; Barboza F, M.

    2011-01-01

    Food processed by ionizing irradiation is a safe technology and has been recognized by the FAO/Who Codes Alimentarius Commission. It is an excellent method to prevent food spoilage and food borne diseases by inhibiting the growth of microorganisms and slowing down ripening. The widespread use of food irradiation treatments that include spices, dry vegetables, grains and fruits make relevant the developing of methods for identification and analyses of foodstuffs processed by irradiation. The present work focuses on the thermoluminescence property of Mexican Roselle flower previously irradiated for detection purposes. The poly mineral content of irradiated commercial Roselle flower (Hibiscus sabdariffa L.) was extracted and analyzed by thermoluminescence (Tl). The X-ray diffraction analyses showed that quartz and albite composition for the poly mineral fraction. Different grain sizes; 10, 53, 74 and 149 μm, were selected for the Tl analyses. The Tl glow curves depended on the grain sizes. The glow curves depicted two peaks around 92 and 120 C. The first peak was ascribed to quartz and the broad part of the glow curves (120-250 C) seems to correspond to the albite. Because the complex structure of the Tl glow curves from poly minerals the kinetic parameters were calculated by a fitting process using a deconvolution method based on a non-linear least-squares Levenberg-Ma quart. The values of the activation energy were found to be at 0.79-1.05 eV and 0.79-1.04 for 53 μm and 250 μm, respectively. The Tl properties of the samples were determined including dose response, reproducibly, fading and UV light bleaching. (Author)

  2. Thermoluminescence response of the poly mineral fraction from hibiscus sabdariffa L foodstuffs

    Energy Technology Data Exchange (ETDEWEB)

    Cruz Z, E.; Guzman, S. [UNAM, Instituto de Ciencias Nucleares, Apdo. Postal 70-543, 04510 Mexico D. F. (Mexico); Brown, F. [Universidad de Sonora, Departamento de Investigacion en Polimeros y Materiales, Apdo. Postal 130, 83000 Hermosillo, Sonora (Mexico); Chernov, V.; Barboza F, M., E-mail: ecruz@nucleares.unam.m [Universidad de Sonora, Departamento de Investigacion en Fisica, Apdo. Postal 5-088, 83190 Hermosillo, Sonora (Mexico)

    2011-02-15

    Food processed by ionizing irradiation is a safe technology and has been recognized by the FAO/Who Codes Alimentarius Commission. It is an excellent method to prevent food spoilage and food borne diseases by inhibiting the growth of microorganisms and slowing down ripening. The widespread use of food irradiation treatments that include spices, dry vegetables, grains and fruits make relevant the developing of methods for identification and analyses of foodstuffs processed by irradiation. The present work focuses on the thermoluminescence property of Mexican Roselle flower previously irradiated for detection purposes. The poly mineral content of irradiated commercial Roselle flower (Hibiscus sabdariffa L.) was extracted and analyzed by thermoluminescence (Tl). The X-ray diffraction analyses showed that quartz and albite composition for the poly mineral fraction. Different grain sizes; 10, 53, 74 and 149 {mu}m, were selected for the Tl analyses. The Tl glow curves depended on the grain sizes. The glow curves depicted two peaks around 92 and 120 C. The first peak was ascribed to quartz and the broad part of the glow curves (120-250 C) seems to correspond to the albite. Because the complex structure of the Tl glow curves from poly minerals the kinetic parameters were calculated by a fitting process using a deconvolution method based on a non-linear least-squares Levenberg-Ma quart. The values of the activation energy were found to be at 0.79-1.05 eV and 0.79-1.04 for 53 {mu}m and 250 {mu}m, respectively. The Tl properties of the samples were determined including dose response, reproducibly, fading and UV light bleaching. (Author)

  3. Neutron spatial distribution measurement with 6Li-contained thermoluminescent sheets

    International Nuclear Information System (INIS)

    Konnai, A.; Odano, N.; Sawamura, H.; Ozasa, N.; Ishikawa, Y.

    2006-01-01

    We have been developing a thermoluminescent (TL) sheet for photon dosimetry (TL sheet) with thermoluminescent material of LiF:Mg, Cu, P and a co-polymer of ethylene and tetrafluoroethylene. For the purpose of a development of simple method for neutron spatial distribution measurement, TL sheet for neutron detection (NTL sheet) is made by adding 94.7% enriched 6 LiF to TL sheet. TL material in TL sheet is directly excited by ionizing radiation whereas, in the case of neutron detection, TL material in NTL sheet is indirectly excited by neutron capture reaction. That is neutron distribution can be obtained with TL caused by α particle from 6 Li(n, α) 3 H reaction. Responses of NTL sheets to neutrons were examined at the neutron beam irradiation facility for Boron Neutron Capture Therapy (BNCT) in JRR-4 research reactor in Japan Atomic Energy Agency. TL and NTL sheets were exposed to striped and roundly distributed neutron fields. Attenuations of neutron flux in air and water were also observed using NTL sheets. TL sheets were also exposed on the same conditions and compared with NTL sheets. TL intensity ratios of NTL sheet to TL sheet were consistent with the calculated value from 6 Li content. Thermal neutron attenuation observed by NTL sheet also corresponded with the result measured by Au wire radioactivation and TLD chips, which were currently used in BNCT at JRR-4. These results were analyzed with by Monte Carlo simulation. The present results indicated that NTL sheet is applicable to measurement of neutron spatial distribution. (author)

  4. Fatal defect in computerized glow curve deconvolution of thermoluminescence

    International Nuclear Information System (INIS)

    Sakurai, T.

    2001-01-01

    The method of computerized glow curve deconvolution (CGCD) is a powerful tool in the study of thermoluminescence (TL). In a system where the plural trapping levels have the probability of retrapping, the electrons trapped at one level can transfer from this level to another through retrapping via the conduction band during reading TL. However, at present, the method of CGCD has no affect on the electron transition between the trapping levels; this is a fatal defect. It is shown by computer simulation that CGCD using general-order kinetics thus cannot yield the correct trap parameters. (author)

  5. On the set up of a thermoluminescent dosimetric system

    International Nuclear Information System (INIS)

    Furetta, C.

    2000-01-01

    In this work are treated the following features: Introduction to the thermoluminescent dosimetric systems, their prerequisites, Initialisation procedure, Batch homogeneity, Procedure for batch homogeneity (IEC), Reference and field dosimeters, Thermal treatments and its general considerations, as well as its initialisation treatment, erasing treatment or standard annealing (also called pre-irradiation annealing), post-irradiation or pre-readout annealing. Also is presented the performance of the annealing study, with its suggested procedures such as: a first and second procedures. Finally, it is showed about experimental data of the annealing treatments and its diagrams. (Author)

  6. Thermoluminescence of the Z centre in Mg-doped KCl

    International Nuclear Information System (INIS)

    Kamavisdar, V.S.; Deshmukh, B.T.

    1980-01-01

    Optical absorption and thermoluminescence measurements on KCl:Mg 2+ are reported. Bleaching in F band introduces a new glow peak at 406 K in the glow curves. A similar peak is observed in microcrystalline powders. When this peak is thermally cleaned, the broadening of the absorption observed in prolonged F bleached crystals is removed. On the basis of these observations, the glow peak at 406 K is tentatively attributed to Z 1 centres. The glow peak at 394 K observed in microcrystalline powders is attributed to a combined effect of deformation and Z 1 centres. (author)

  7. Comparative study of thermoluminescent efficiencies before variation of experimental factors

    International Nuclear Information System (INIS)

    Avila, O.; Estrada, D.; Gonzalez, P.; Rodriguez V, M.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E.; Gamboa de Buen, I.; Aviles, P.; Horowitz, Y.S.

    2001-01-01

    An investigation for quantifying the influence of varying distinct experimental factors in the measurements of relative thermoluminescent efficiency of 3 MeV protons was realized with respect to gamma radiation in LiF: Mg, Ti. Variations in a dosemeters batch were considered, as presentation, applied thermal treatments and reader equipment. The main conclusion of this work is to emphasize the importance for measuring entire series of experiments in the same laboratory following a protocol defined carefully and using dosemeters of the same batch for obtaining response before charging particle and the response before gamma radiation with identical procedures of baking and reading. (Author)

  8. Performance of thermoluminescent materials for high dose dosimetry

    International Nuclear Information System (INIS)

    Texeira, Maria I.; Cecatti, Sonia G.P.; Caldas, Linda V.E.

    2008-01-01

    Cases involving high-doses of ionizing radiation are becoming increasingly common.The objective of this work was to characterize thermoluminescent materials for the dosimetry of workers exposed to high doses. Samples of TLD-200, TLD-400 and TLD-800 pellets from Thermo Electron Corporation were studied in gamma high-doses. Dose-response curves were obtained for doses between 100 mGy and 100 Gy. The reproducibility, the lower detection limits and dose-response curves were obtained for all three materials. The different kinds of detectors show usefulness for dosimetry of workers exposed accidentally to high doses. (author)

  9. Thermoluminescence measurements of neutron streaming through JET Torus Hall ducts

    OpenAIRE

    Obryk, Barbara; Batistoni, Paola; Conroy, Sean; Syme, Brian D.; Popovichev, Sergey; Stamatelatos, Ion E.; Vasilopoulou, Theodora; Bilski, Paweł; Contributors, JET EFDA

    2014-01-01

    Thermoluminescence detectors (TLD) were used for dose measurements at JET. Several hundreds of LiF detectors of various types, standard LiF:Mg,Ti and highly sensitive LiF:Mg,Cu,P were produced. LiF detectors consisting of natural lithium are sensitive to slow neutrons, their response to neutrons being enhanced by 6Li-enriched lithium or suppressed by using lithium consisting entirely of 7Li. Pairs of 6LiF/7LiF detectors allow distinguishing between neutron/non-neutron components of a radiatio...

  10. Personnel radiation monitoring by thermoluminescence dosimetry (1995-96)

    International Nuclear Information System (INIS)

    Daw Mi Cho Cho; Daw Yi Yi Khin; Daw San San; U Maung Maung Tin; Daw Hla Hla Win

    2001-01-01

    Personnel radiation monitoring which is the dose assessment of individual doses from external radiation received by radiation workers has been carried out by Thermoluminescence Dosimetry system consisting of a Vinten Toledo TLD reader, LiF dosimeters and associated equipment. The exposed TLD dosimeters were measured by TLD reader and the dose evaluation and dose registration were done on personal computer. Due to the records of 1995-96, most of the radiation workers complied with the permissible dose recommended by IAEA and ICRP 60. (author)

  11. Development of BaSO4:Eu thermoluminescence phosphor

    International Nuclear Information System (INIS)

    Madhusoodanan, U.; Jose, M.T.; Lakshmanan, A.R.

    1999-01-01

    A highly sensitive thermoluminescence (TL) phosphor based on BaSO 4 :Eu was developed following the coprecipitation technique and firing in argon atmosphere at 1123 K. Photoluminescence studies confirm that firing in argon atmosphere instead of air increased the incorporation of Eu ions in 2+ valence state. At low γ-ray doses, its TL sensitivity is nearly 2 to 3 times higher than that of CaSO 4 :Dy phosphor. The other salient features of this BaSO 4 :Eu TL phosphor are a constant glow curve shape and a nearly linear γ-ray dose response

  12. Thermoluminescent determination of prehistoric heat treatment of chert artifacts

    International Nuclear Information System (INIS)

    Melcher, C.L.; Zimmerman, D.W.

    1977-01-01

    In recent years archeologists have become interested in the extent to which prehistoric peoples heat-treated chert prior to shaping it into tools. Thermoluminescent determination of the radiation dose accumulated by an artifact since it was formed or last heated provides a simple, reliable test for such heat treatment. This test can be applied to single artifacts without the need for raw source material for comparison. Results on 25 artifacts from four sites indicate that, for many chert sources, color and luster are not useful indicators of heat treatment by prehistoric peoples

  13. Method of making isodose curve using thermoluminescence dosemeter

    International Nuclear Information System (INIS)

    Bakar Ramain, A.

    1975-01-01

    Line source of 60 Co in the form of needles and tubes are extensively used in radiotherapy in moulds, implants, and intracavitary techniques for the treatment of malignant lesions. It is important to have isodose distributions in tissue for those source for purposes of treatment planning. The isodose distributions have been obtained experimentally by using tinny lithium-fluoride (Lsub(i)F) thermoluminescent dosemeters (TLD) and they are compared to the theoretical results. The distinct advantages of Lsub(i)F (TLD) in such measurements are briefly discussed. (author)

  14. Dating pleistocene fossil coastal sand dunes by thermoluminescence

    International Nuclear Information System (INIS)

    Poupeau, G.; Souza, J.H.; Soliani Junior, E.; Loss, E.L.

    1983-01-01

    It was shown recently that sunlight exposure is able to bleach most of the geological thermoluminescence (TL) of wind transported sediments. This property has been used in an attempt to date dunes from the well developed recent quaternary coastal dunes system of Rio Grande do Sul. Preliminary results presented here, show that TL dating on fossil sand dunes from Rio Grande do Sul should be possible in a time range from present to at least 50.000 yr and possibly more than 100.000 yr. (Author) [pt

  15. Application of thermoluminescence analysis for detection of irradiated foodstuffs

    International Nuclear Information System (INIS)

    Malec-Czechowska, K.; Dancewicz, M.; Szot, Z.

    1996-01-01

    Investigations on the development conditions necessary to obtain reliable results of the detection of irradiated herbs, spices, mushrooms and strawberries by thermoluminescence (Tl) method in whole samples and/or in minerals isolated from them carried out. Tl intensities of whole samples were measured between 40 an 355 C. Threshold values for non-irradiated samples were obtained by multiplying Tl values of control samples by 3 (safety factor). Samples in which Tl intensities were higher than the threshold values were identified as irradiated. In 4 out of 10 kind of herbs and spices examined the results of Tl measurements led to false identification. (author). 14 refs, 1 fig., 5 tabs

  16. Environmental radiation measurements using lithium fluoride thermoluminescence dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Driscoll, C.M.H.; Green, B.M.R.; McKinlay, A.F.; Richards, D.J. (National Radiological Protection Board, Harwell (UK))

    1984-01-01

    The National Radiological Protection Board is involved in a large scale environmental survey of radiation levels in homes throughout the United Kingdom. Passive radon and gamma ray dosemeters are posted to a representative sample of households. Lithium fluoride thermoluminescence dosemeters are used to assess natural gamma radiation and are left in the measurement location for a period of six months before being returned to the Board for processing. As a preliminary to the national survey, the Board has been engaged on several limited surveys in regions of igneous and sedimentary geology. Experience gained in these limited surveys and from standardisation studies using environmental dosemeters are reported.

  17. Development of BaSO sub 4 :Eu thermoluminescence phosphor

    CERN Document Server

    Madhusoodanan, U; Lakshmanan, A R

    1999-01-01

    A highly sensitive thermoluminescence (TL) phosphor based on BaSO sub 4 :Eu was developed following the coprecipitation technique and firing in argon atmosphere at 1123 K. Photoluminescence studies confirm that firing in argon atmosphere instead of air increased the incorporation of Eu ions in 2+ valence state. At low gamma-ray doses, its TL sensitivity is nearly 2 to 3 times higher than that of CaSO sub 4 :Dy phosphor. The other salient features of this BaSO sub 4 :Eu TL phosphor are a constant glow curve shape and a nearly linear gamma-ray dose response.

  18. Detecting irradiation of strawberries by means of thermoluminescence measurement

    International Nuclear Information System (INIS)

    Heide, L.; Guggenberger, R.; Boegl, K.W.

    1989-01-01

    Investigations into the origin of the thermoluminescence (TL) have shown that this effect is due to trace amounts of mineral particulates adhering to the irradiated material. This result and own experience have led to the development of the TL-based method for post-factum detection of an irradiation of strawberries. In addition to the analysis of whole fruits, a method has been tested that proceeds via separation of adhering matter to separate TL analysis of the particulates. The results obtained so far show no difference or improvement as compared to whole-fruit TL analysis. (orig./MG) [de

  19. Exoemission and thermoluminescence from human enamel and shark enameloid

    International Nuclear Information System (INIS)

    Davies, J.E.

    1983-01-01

    Simultaneous measurements of exoelectron emission and thermoluminescence from powdered biological apatites, which have not been chemically or thermally pretreated, are reported. Recycling, that is, consecutive irradiation and non-isothermal scanning, is shown to change both the form of the glow curves and emissivity of samples. Two biological apatites of the hydroxyapatite type (human enamel) and fluorapatite type (shark enameloid) are compared. Although their initial glow curves are different, recycling renders the glow curves similar suggesting that the defects involved are a product of the host lattice. The relevance of exoemission as a ''fingerprinting'' technique for biologically reactive material is discussed. (author)

  20. Use of thermoluminescent dosimetry in gamma radiation fields studies

    International Nuclear Information System (INIS)

    Carron, W.

    1987-01-01

    The depth-dose curves for gamma rays in material of interest to agronomy were obtained using lithium fluoride thermoluminescent dosimeters. The dose conversion factors for LiF were determined from curves of the absorved dose versus depth in water, wood and soil. Mathematics equations were chosen to best fit these curves. In the view of the results we came to the conclusion that in the studied materials the absorved radiation dose presents a great variation to the depth and could be correlated through of the exponential regression. (author)