WorldWideScience

Sample records for storage concepts refrigerated-mined

  1. Advanced Gas Storage Concepts: Technologies for the Future

    Energy Technology Data Exchange (ETDEWEB)

    Freeway, Katy (PB-KBB Inc.); Rogers, R.E. (Mississippi State University); DeVries, Kerry L.; Nieland, Joel D.; Ratigan, Joe L.; Mellegard, Kirby D. (RESPEC)

    2000-02-01

    This full text product includes: 1) A final technical report titled Advanced Underground Gas Storage Concepts, Refrigerated-Mined Cavern Storage and presentations from two technology transfer workshops held in 1998 in Houston, Texas, and Pittsburgh, Pennsylvania (both on the topic of Chilled Gas Storage in Mined Caverns); 2) A final technical report titled Natural Gas Hydrates Storage Project, Final Report 1 October 1997 - 31 May 1999; 3) A final technical report titled Natural Gas Hydrates Storage Project Phase II: Conceptual Design and Economic Study, Final Report 9 June - 10 October 1999; 4) A final technical report titled Commerical Potential of Natural Gas Storage in Lined Rock Caverns (LRC) and presentations from a DOE-sponsored workshop on Alternative Gas Storage Technologies, held Feb 17, 2000 in Pittsburgh, PA; and 5) Phase I and Phase II topical reports titled Feasibility Study for Lowering the Minimum Gas Pressure in Solution-Mined Caverns Based on Geomechanical Analyses of Creep-Induced Damage and Healing.

  2. Prediction of thermodynamic properties of refrigerants using data mining

    International Nuclear Information System (INIS)

    Kuecueksille, Ecir Ugur; Selbas, Resat; Sencan, Arzu

    2011-01-01

    The analysis of vapor compression refrigeration systems requires the availability of simple and efficient mathematical formulations for the determination of thermodynamic properties of refrigerants. The aim of this study is to determine thermodynamic properties as enthalpy, entropy and specific volume of alternative refrigerants using data mining method. Alternative refrigerants used in the study are R134a, R404a, R407c and R410a. The results obtained from data mining have been compared to actual data from the literature. The study shows that the data mining methodology is successfully applicable to determine enthalpy, entropy and specific volume values for any temperature and pressure of refrigerants. Therefore, computation time reduces and simulation of vapor compression refrigeration systems is fairly facilitated.

  3. A new compressed air energy storage refrigeration system

    International Nuclear Information System (INIS)

    Wang Shenglong; Chen Guangming; Fang Ming; Wang Qin

    2006-01-01

    In this study, a new compressed air energy storage (CAES) refrigeration system is proposed for electrical power load shifting application. It is a combination of a gas refrigeration cycle and a vapor compression refrigeration cycle. Thermodynamic calculations are conducted to investigate the performance of this system. Economic analysis is performed to study the operating cost of the system, and comparison is made with a vapor compression refrigeration system and an ice storage refrigeration system. The results indicate that the CAES refrigeration system has the advantages of simple structure, high efficiency and low operating cost

  4. Functional Dependence of Thermodynamic and Thermokinetic Parameters of Refrigerants Used in Mine Air Refrigerators. Part 1 - Refrigerant R407C

    Science.gov (United States)

    Nowak, Bernard; Życzkowski, Piotr; Łuczak, Rafał

    2017-03-01

    The authors of this article dealt with the issue of modeling the thermodynamic and thermokinetic properties (parameters) of refrigerants. The knowledge of these parameters is essential to design refrigeration equipment, to perform their energy efficiency analysis, or to compare the efficiency of air refrigerators using different refrigerants. One of the refrigerants used in mine air compression refrigerators is R407C. For this refrigerant, 23 dependencies were developed, determining its thermodynamic and thermokinetic parameters in the states of saturated liquid, dry saturated vapour, superheated vapor, subcooled liquid, and in the two-phase region. The created formulas have been presented in Tables 2, 5, 8, 10 and 12, respectively. It should be noted that the scope of application of these formulas is wider than the range of changes of that refrigerant during the normal operation of mine refrigeration equipment. The article ends with the statistical verification of the developed dependencies. For this purpose, for each model correlation coefficients and coefficients of determination were calculated, as well as absolute and relative deviations between the given values from the program REFPROP 7 (Lemmon et al., 2002) and the calculated ones. The results of these calculations have been contained in Tables 14 and 15.

  5. Freezing and refrigerated storage in fisheries

    National Research Council Canada - National Science Library

    Johnston, W. A

    1994-01-01

    ...; the factors affecting cold storage conditions, etc. In addition, the publication describes the methods used to calculate cold storage refrigeration loads as well as the costs of freezing and cold storage...

  6. Refrigeration requirements for fusion reactors based upon the theta-pinch concept

    International Nuclear Information System (INIS)

    Williamson, K.D. Jr.; King, C.R.

    1976-01-01

    Two refrigeration systems applicable to the theta-pinch fusion concept are described. The first is a 1100 W, 4.5 K refrigerator which will be used for testing superconducting NbTi Magnetic Energy Transfer and Storage (METS) coil systems. This unit is currently being installed and is to be operational by April 1977. The second unit is applicable to the Syllac Fusion Test Reactor (SFTR) and has been conceptually designed. This liquefier-refrigerator is about 22 times larger than those in existence at present and will require 12-MW input electrical power. It will provide 3045 kg/h of liquid helium at 4.5 K

  7. Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry

    Science.gov (United States)

    Rasta, IM; Susila, IDM; Subagia, IWA

    2018-01-01

    The application of refrigeration technology to postharvest fishery products is an very important. Moreover, Indonesia is a tropical region with relatively high temperatures. Fish storage age can be prolonged with a decrease in temperature. Frozen fish can even be stored for several months. Fish freezing means preparing fish for storage in low-temperature cold storage. The working fluid used in cold storage to cool low-temperature chambers and throw heat into high-temperature environments is refrigerant. So far refrigerant used in cold storage is Hydrochloroflourocarbons (HCFC) that is R-22. Chlor is a gas that causes ODP (Ozone Depleting Potential), while Flour is a gas that causes GWP (Global Warming Potential). Government policy began in 2015 to implement Hydrochloroflourocarbons Phase-Out Management Plan. Hydrocarbon (HC) is an alternative substitute for R-22. HC-22 (propane ≥ 99.5%) has several advantages, among others: environmentally friendly, indicated by a zero ODP value, and GWP = 3 (negligible), thermophysical property and good heat transfer characteristics, vapor phase density Which is low, and good solubility with mineral lubricants. The use of HC-22 in cold storage is less than R-22. From the analysis results obtained, cold storage system using HC-22 has better performance and energy consumption is more efficient than the R-22.

  8. Analysis of energy saving performance for household refrigerator with thermal storage of condenser and evaporator

    International Nuclear Information System (INIS)

    Cheng, Wen-long; Ding, Miao; Yuan, Xu-dong; Han, Bing-Chuan

    2017-01-01

    Highlights: • A novel refrigerator with both HSC and CSE is proposed. • The operational characteristics of novel refrigerator is analyzed. • The comparison of CSE, HSC and DES refrigerators is analyzed. • DES refrigerator has a largest off-time to on-time ratio of 4.3. • DES refrigerator has the best electrical energy saving performance (32%). - Abstract: The heat transfer performances of evaporators and condensers significantly affect the efficiency of household refrigerators. For enhancing heat transfer of the condensers and evaporators, a novel dual energy storage (DES) refrigerator with both heat storage condenser (HSC) and cold storage evaporator (CSE) is proposed. The performance comparison of three kinds of energy storage refrigerators: HSC refrigerator, CSE refrigerator and DES refrigerator is analyzed by establishing dynamic simulation models. According to the simulation results, the DES refrigerator combines the advantage of HSC refrigerator and CSE refrigerator, it has more balanced operational cycle and higher evaporation pressure and temperature. The DES refrigerator shows a best energy saving performance among the three energy storage refrigerators with largest off-time to on-time ratio of 4.3 and the electrical consumption saving can reach 32%, which is greater than the sum (28%) of the other two kinds of energy storage refrigerators.

  9. Data mining techniques for thermophysical properties of refrigerants

    International Nuclear Information System (INIS)

    Kuecueksille, Ecir Ugur; Selbas, Resat; Sencan, Arzu

    2009-01-01

    This study presents ten modeling techniques within data mining process for the prediction of thermophysical properties of refrigerants (R134a, R404a, R407c and R410a). These are linear regression (LR), multi layer perception (MLP), pace regression (PR), simple linear regression (SLR), sequential minimal optimization (SMO), KStar, additive regression (AR), M5 model tree, decision table (DT), M5'Rules models. Relations depending on temperature and pressure were carried out for the determination of thermophysical properties as the specific heat capacity, viscosity, heat conduction coefficient, density of the refrigerants. Obtained model results for every refrigerant were compared and the best model was investigated. Results indicate that use of derived formulations from these techniques will facilitate design and optimize of heat exchangers which is component of especially vapor compression refrigeration system

  10. Enhancement of refrigerated storage of Elasmobranchs by gamma irradiation

    International Nuclear Information System (INIS)

    Ghadi, S.V.; Lewis, N.F.

    1976-01-01

    Elasmobranch fish varieties including shark, ray and skate fish, are very susceptible to microbial spoilage because of high levels of urea in their muscle, giving rise to rapid formation of copious quantities of ammonia. Steaming of fish filleta prior to processing has been found to reduce the urea content thereby leading to better odour and flavour retention of the product. However, steaming of Elasmobranch fish fillets results in only a marginal increase in refrigerated storage. Gamma irradiation doses in the range 100-500 krad did not appreciably extend the refrigerated storage Elasmobranchs. However, steaming for five minutes followed by gamma irradiation exposure (100-250 krad) was found to give a 4-5 fold enhancement in the refrigerated storage life of these fish. Representative samples of fish given different treatments were examined at regular intervals during storage at 0-2 degC for sensory evaluation, total bacterial count and chemical freshness indices. (author)

  11. Experimental Results of Integrated Refrigeration and Storage System Testing

    Science.gov (United States)

    Notardonato, W. U.; Johnson, W. L.; Jumper, K.

    2009-01-01

    Launch operations engineers at the Kennedy Space Center have identified an Integrated Refrigeration and Storage system as a promising technology to reduce launch costs and enable advanced cryogenic operations. This system uses a close cycle Brayton refrigerator to remove energy from the stored cryogenic propellant. This allows for the potential of a zero loss storage and transfer system, as well and control of the state of the propellant through densification or re-liquefaction. However, the behavior of the fluid in this type of system is different than typical cryogenic behavior, and there will be a learning curve associated with its use. A 400 liter research cryostat has been designed, fabricated and delivered to KSC to test the thermo fluid behavior of liquid oxygen as energy is removed from the cryogen by a simulated DC cycle cryocooler. Results of the initial testing phase focusing on heat exchanger characterization and zero loss storage operations using liquid oxygen are presented in this paper. Future plans for testing of oxygen densification tests and oxygen liquefaction tests will also be discussed. KEYWORDS: Liquid Oxygen, Refrigeration, Storage

  12. Materials used in refrigerated storage system

    Energy Technology Data Exchange (ETDEWEB)

    Abakians, H

    1970-09-01

    Applications of cryogenic technology have increased at a phenomenal rate during the past decade. With the installation of a number of refrigerated storage tanks in Iran, e.g., LPG storage at Bandar Mah Shahr and Kharg Is., and ammonia storage at Bandar Shahpour, it is appropriate to review the materials used in constructing low temperature storage systems. In order to have an economical fully refrigerated storage installation without assuming the risk of brittle fracture, appropriate notch-tough material should be selected for the important and highly stressed components. In general, the lower the operating temperature, the more expensive is the material to be used. Hence, care should be taken to select the required material in such a manner that it will be suitable for the operating temperature and not lower. The most economical materials for low temperatures are steels. Ordinary carbon steel can be used down to -20$F and the Killed carbon steel down to -50$F. Nickel steels (2 1/4%) can be used down to -75$ to 100$F, Nickel steels (3 1/2%) down to -150$F, and 9% nickel steels down to 1,320$F. Stainless and aluminum alloys can be used down to -423$F. Tabular data give some commonly used materials in low temperature and cryogenic services with their lowest allowable temperature, tensile strength, and relative cost.

  13. Fuzzy Control of Cold Storage Refrigeration System with Dynamic Coupling Compensation

    Directory of Open Access Journals (Sweden)

    Xiliang Ma

    2018-01-01

    Full Text Available Cold storage refrigeration systems possess the characteristics of multiple input and output and strong coupling, which brings challenges to the optimize control. To reduce the adverse effects of the coupling and improve the overall control performance of cold storage refrigeration systems, a control strategy with dynamic coupling compensation was studied. First, dynamic model of a cold storage refrigeration system was established based on the requirements of the control system. At the same time, the coupling between the components was studied. Second, to reduce the adverse effects of the coupling, a fuzzy controller with dynamic coupling compensation was designed. As for the fuzzy controller, a self-tuning fuzzy controller was served as the primary controller, and an adaptive neural network was adopted to compensate the dynamic coupling. Finally, the proposed control strategy was employed to the cold storage refrigeration system, and simulations were carried out in the condition of start-up, variable load, and variable degree of superheat, respectively. The simulation results verify the effectiveness of the fuzzy control method with dynamic coupling compensation.

  14. Detection of airborne psychrotrophic bacteria and fungi in food storage refrigerators

    Directory of Open Access Journals (Sweden)

    Sema Sandikci Altunatmaz

    2012-12-01

    Full Text Available The purpose of this study was to determine the microbiological air quality (psychrotrophic bacteria and airborne fungi and distribution of fungi in different types of ready-to-eat (RTE food-storage refrigerators (n=48 at selected retail stores in the city of Edirne, Turkey. Refrigerators were categorized according to the type of RTE food-storage: meat products, vegetables, desserts, or a mix of food types. Microbiological quality of air samples was evaluated by using a Mas-100 Eco Air Sampler. Four refrigerators (all containing meat products, 8.3% produced air samples with undetectable microorganisms. The highest detected mean value of airborne psychrotrophic bacteria and fungi was 82.3 CFU/m³ and 54.6 CFU/m³, respectively and were found in mixed-food refrigerators. The dominant airborne fungal genera found were Penicillium (29.0%, Aspergillus (12.0%, Mucor (9%, Cladosporium (8%, Botyrtis (7%, and Acremonium (6%. By definition, RTE food does not undergo a final treatment to ensure its safety prior to consumption. Therefore, ensuring a clean storage environment for these foods is important to prevent food-borne disease and other health risks.

  15. Extending the Refrigerated Storage of Red Blood Cells

    National Research Council Canada - National Science Library

    Bitensky, Mark

    2004-01-01

    Oxygen removal increases shelf-life and quality of refrigerated blood. The shelf life of our blood has been prolonged to a minimum of 12 weeks with survival equal to or greater than that of conventional 6 week storage...

  16. Integrated Refrigeration and Storage for Advanced Liquid Hydrogen Operations

    Science.gov (United States)

    Swanger, A. M.; Notardonato, W. U.; Johnson, W. L.; Tomsik, T. M.

    2016-01-01

    NASA has used liquefied hydrogen (LH2) on a large scale since the beginning of the space program as fuel for the Centaur and Apollo upper stages, and more recently to feed the three space shuttle main engines. The LH2 systems currently in place at the Kennedy Space Center (KSC) launch pads are aging and inefficient compared to the state-of-the-art. Therefore, the need exists to explore advanced technologies and operations that can drive commodity costs down, and provide increased capabilities. The Ground Operations Demonstration Unit for Liquid Hydrogen (GODU-LH2) was developed at KSC to pursue these goals by demonstrating active thermal control of the propellant state by direct removal of heat using a cryocooler. The project has multiple objectives including zero loss storage and transfer, liquefaction of gaseous hydrogen, and densification of liquid hydrogen. The key technology challenge was efficiently integrating the cryogenic refrigerator into the LH2 storage tank. A Linde LR1620 Brayton cycle refrigerator is used to produce up to 900W cooling at 20K, circulating approximately 22 g/s gaseous helium through the hydrogen via approximately 300 m of heat exchanger tubing. The GODU-LH2 system is fully operational, and is currently under test. This paper will discuss the design features of the refrigerator and storage system, as well as the current test results.

  17. Impact of Refrigerated Storage on Quality of Oil from Freshwater Jarko (Wallago attu Fish.

    Directory of Open Access Journals (Sweden)

    Nusrat N. Memon

    2010-12-01

    Full Text Available The effect of refrigerated storage on the quality of freshwater fish oil Jarko (Wallago attu was evaluated by measuring fatty acid profile, free fatty acids (FFA, peroxide value (PV, acid value (AV, sponification value (SV, iodine value (IV and poylene index (PI up to the time period of 120 days. After 120 days storage, mono unsaturated fatty acids (MUFA and polyunsaturated fatty acids (PUFA contents were decreased by 24.89% and 33.70%, respectively. While, saturated fatty acids (SFA content was found to be increased by 26.82%, against the actual value. The change in polyunsaturated fatty acids during refrigerated storage was measured by the PI value. The PI decreased during storage due to lipid oxidation, but remained nearly constant after 90th day of storage. The results of PV, AV and FFA demonstrates that Wallago attu fish oil remained acceptable for consumption for 60 days but eventually exceeded the recommended values after 60 days of refrigerated storage.

  18. Thermodynamic, Environmental and Economic Analyses of Solar Ejector Refrigeration System Application for Cold Storage

    Directory of Open Access Journals (Sweden)

    İbrahim ÜÇGÜL

    2009-02-01

    Full Text Available The refrigeration processes have been widely applied for especially in cold storages. In these plants, the systems working with compressed vapour cooling cycles have been used as a classical method. In general, electrical energy is used for compressing in these processes. Although, mainly the electricity itself has no pollution effect on the environment, the fossil fuels that are widely used to produce electricity in the most of the world, affect the nature terribly. In short, these refrigeration plants, because of the source of the electricity pollute the nature indirectly. However, for compression an ejector refrigeration system requires one of the important renewable energy sources with negligible pollution impact on the environment, namely solar energy from a thermal source. Thermodynamical, environmental and economical aspects of the ejector refrigeration system working with solar energy was investigated in this study. As a pilot case, apple cold storage plants widely used in ISPARTA city, which 1/5 th of apple production of TURKEY has been provided from, was chosen. Enviromental and economical advantages of solar ejector refrigeration system application for cold storage dictated by thermodynamic, economic and enviromental analyses in this research.

  19. Space Station thermal storage/refrigeration system research and development

    Science.gov (United States)

    Dean, W. G.; Karu, Z. S.

    1993-01-01

    Space Station thermal loading conditions represent an order of magnitude increase over current and previous spacecraft such as Skylab, Apollo, Pegasus III, Lunar Rover Vehicle, and Lockheed TRIDENT missiles. Thermal storage units (TSU's) were successfully used on these as well as many applications for ground based solar energy storage applications. It is desirable to store thermal energy during peak loading conditions as an alternative to providing increased radiator surface area which adds to the weight of the system. Basically, TSU's store heat by melting a phase change material (PCM) such as a paraffin. The physical property data for the PCM's used in the design of these TSU's is well defined in the literature. Design techniques are generally well established for the TSU's. However, the Space Station provides a new challenge in the application of these data and techniques because of three factors: the large size of the TSU required, the integration of the TSU for the Space Station thermal management concept with its diverse opportunities for storage application, and the TSU's interface with a two-phase (liquid/vapor) thermal bus/central heat rejection system. The objective in the thermal storage research and development task was to design, fabricate, and test a demonstration unit. One test article was to be a passive thermal storage unit capable of storing frozen food at -20 F for a minimum of 90 days. A second unit was to be capable of storing frozen biological samples at -94 F, again for a minimum of 90 days. The articles developed were compatible with shuttle mission conditions, including safety and handling by astronauts. Further, storage rack concepts were presented so that these units can be integrated into Space Station logistics module storage racks. The extreme sensitivity of spacecraft radiator systems design-to-heat rejection temperature requirements is well known. A large radiator area penalty is incurred if low temperatures are accommodated via a

  20. The use of cold storage in household refrigerators

    International Nuclear Information System (INIS)

    Michael, Y.C.; Yang, K.T.

    1991-01-01

    A simulated household refrigerator was built that utilizes latent Thermal Energy Storage (TES) to reduce the on-off frequency of the compressor. It was found that the on-off frequency was reduced by a factor of six and that the energy consumption was less for a certain range of refrigerated space temperatures. A new evaporator design was used to accommodate the Phase Change Material (PCM). The evaporator consisted of four thin plates filled with PCM which were connected in parallel. The temperature distribution inside the PCM was also measured and the results are discussed. The PCM used was an aqueous solution of propylene glycol. In this paper freezing characteristics as well as some estimate of its latent heat are also discussed

  1. Bacteriological quality of raw human milk: effect of storage in a refrigerator.

    Science.gov (United States)

    Olowe, S A; Ahmed, I; Lawal, S F; Ransome-Kuti, S

    1987-12-01

    Eighty-seven breast milk samples were obtained from 63 mothers of infants on the neonatal intensive care unit of the Lagos University Teaching Hospital. The samples were cultured for bacteria immediately after collection (0 h) and then stored in a domestic refrigerator from where cultures were repeated at 6-hourly intervals for 24 h. At 0 h, three (3.4%) of the samples were sterile; 56 (64%) grew coagulase negative staphylococci, and one (1.1%) Streptococcus viridans. Thus, 60 (69%) of the samples were either sterile or contained only skin commensals. Twenty-nine (31%) grew potential pathogens--coagulase positive staphylococci in two (2.3%) and mixed growth of staphylococci, coliforms and klebsiella in 25 (28.3%). During the 24 h storage in the refrigerator, bacteria multiplied in 50 and their growth was inhibited in 32 of the samples. But the mean bacterial count at any time during the 24 h was not significantly different from that at the beginning of the storage in the refrigerator. It is proposed that expressed breast milk stored in a domestic refrigerator can be given safely to infants within 24 h of collection if heavy contamination is prevented at the time of collection.

  2. Vapor Compression Refrigeration System for Cold Storage on Spacecrafts, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA is looking for a high efficiency long term food storage system for space crafts. Previous refrigerator/freezer systems developed for this application such as...

  3. Towards a sustainable mining law: geothermal, CO2 capture and geological storage?

    International Nuclear Information System (INIS)

    Lanoy, Laurence

    2013-01-01

    The author comments how the French mining code has been able to adapt itself to the development of new techniques such as geothermal power, CO 2 capture and storage in a context of environmental concerns. She comments how the mining code evolved towards a new concept of soil use and valorisation in relationship with the development of these techniques, and how the mining code has thus become a new actor in the field of renewable energies. Its reform is briefly discussed

  4. Design and dynamic behaviour of a cold storage system combined with a solar powered thermoacoustic refrigerator

    International Nuclear Information System (INIS)

    Perier-Muzet, Maxime; Bedecarrats, Jean-Pierre; Stouffs, Pascal; Castaing-Lasvignottes, Jean

    2014-01-01

    A heat powered thermoacoustic refrigerator consists in a thermoacoustic engine that produces acoustic work utilizing heat, coupled to a thermoacoustic cooler that converts this acoustic energy into cooling effect. These machines have already proved their capability in laboratory or in space refrigeration. Previous studies have also demonstrated the possibility of using concentrated solar energy as thermal energy sources for low power heat driven thermoacoustic refrigerators. As other solar refrigeration systems, even if the cooling demand generally increases with the intensity of the solar radiation, one of the major difficulties is to insure a frigorific power supply when there is no, or low, solar radiation. The aim of this work is to study a kW scale solar thermoacoustic refrigerator capable to reach temperatures of the industrial refrigeration domain. This refrigerator is combined with a latent cold storage in order to guarantee a sufficient cooling capacity to face to refrigeration loads in spite of the production fluctuations. A description of the studied prototype is done and the model developed to describe the transient behaviour of the main components of this machine is introduced. The results obtained with a simulation of one week with real solar radiations are presented and the behaviour and the energetic performances of the entire system are analysed. Finally the impact of the sizing of the cold storage system is discussed. With the best storage design, the system is capable to supply a cooling power of 400 W at a temperature equal or lower than −20 °C with an average Coefficient Of Performance of the solar thermoacoustic refrigerator equal to 21%

  5. Effect of gamma irradiation on refrigerator storage of peach fruits

    International Nuclear Information System (INIS)

    Kalinov, V.

    1985-01-01

    Peach fruits of cvs. Halle and Elberta were gamma irradiated by 0, 2.0, 2.5 and 3.0 kGy and stored in the usual way (20-25 grad C) or in refrigerator (5 and 0 grad C). The rate of mould decay, reduction in market quality and complex evaluation of the fruits at the time of storage were investigated. Linear regression correlations between the percentage of decay and the time of storage were estimated by probit-logarithmic transformation of the percentage of the decayed fruits. On that basis were assess the probable terms to reach 5% decay (permissible period of storage) and 10% decay. The criteria of quality and taste evaluation of the fruits for these periods were determined. The irradiation of peach fruits with 2.5 and 3.0 kGy prolonged 3 to 5 times the period free of decay (up to 5%) in the case of normal storage conditions as compared to the control (no irradiation). The sharp reduction in quality and the sensorial evaluation for these periods did not justify irradiation in case of usual storage conditions. Irradiation with the same rates in case of refrigeration storage proved a useful supplementary factor prolonging the periods before appearance of decay up to 17 days (i.e. 42% as compared to the control) and the permissible period of storage up to 25 days (25% more than the control). These results were obtained at a dose of 2.5 kGy for cv. Halle fruits, at dose 3.0 kGy for cv. Elberta fruits and at storage temperature of 0 grad C. For the periods up to 5% decay (25 to 26 days) the criteria of quality and the complex evaluation remained above the permissible level. Longer storage was not advisable because physiological damage of the fruit was evident

  6. Current status of development on superconducting magnetic energy storage systems and magnetic refrigeration

    International Nuclear Information System (INIS)

    Hirano, Naoki

    2010-01-01

    Superconducting magnetic energy storage (SMES) systems have excellent characteristics as energy-storage equipment in power systems such as high efficiency, quick response, and no deterioration in repetitive operations. There are many projects to develop SMES throughout the world. Since 1991, a national project by the Agency for Natural Resources and Energy Japan has been working to develop an SMES system to control power in power systems. Moreover, SMES has been developed to compensate for momentary voltage dips since 2003. To reduce energy consumption due to prolonged operating times, we developed energy-conserving electrical equipment incorporating refrigerating aggregates such as air conditioners. We conduced R and D to convert magnetic refrigeration and highly-efficient, energy-conserving/environmentally friendly technologies, to practical applications. The current status in the development of SMES to control power systems, bridging to deal with instantaneous voltage dips, and magnetic refrigeration technology will be explained in this paper. (author)

  7. 'TEWI' concept for estimation of the global warming from the refrigerating and air conditioning systems

    International Nuclear Information System (INIS)

    Ciconkov, Risto

    2002-01-01

    The most applied CFC refrigerants and their HFC alternatives. values of ODP (Ozone Depletion Potential) and GWP (Global Warming Potential) of the most used refrigerants. natural working fluids and their properties. Montreal Protocol and Kyoto Protocol, illogical relations between them concerning to the HFC fluids. Confusion and polemics on the international level about the appliance of HFCs which, by the Kyoto Protocol, are liable to reduction. Introduction of the TEWI concept as a method for estimating the overall influence of refrigerating and air conditioning systems on the greenhouse effect: the direct emission (refrigerant leakage in the atmosphere) and indirect emission as a result of the electrical energy consumption. A demonstration of the TEWI concept on the concrete example in several variants. A discussion about the appliance of the TEWI concept. Meaning of the energy efficiency of the refrigerating systems (indirect CO 2 emission). One of the main measures: prevention of refrigerant leakage (direct CO 2 emission). A need of permanent education and training courses of the people who work on refrigerating and air conditioning systems. A necessity for constitution of an expert body in the country, preparation of a strategy to lay obligations on the new changes of the Kyoto Protocol and news on the world market. Introduction of country regulations, certification of the companies and people involved in refrigeration and air conditioning. (Author)

  8. Urine storage under refrigeration preserves the sample in chemical, cellularity and bacteriuria analysis of ACS

    Directory of Open Access Journals (Sweden)

    Karen Cristina Barcellos Ribeiro

    2013-12-01

    Full Text Available INTRODUCTION: The analysis of urine abnormal constituents and sediment (ACS comprises tests of great diagnostic and prognostic value in clinical practice. When the analysis of ACS cannot be performed within two hours after collection, the sample must be preserved in order to avoid pre-analytical interferences. Refrigeration is the most applied technique due to its cost effectiveness. Moreover, it presents fewer inconveniences when compared to chemical preservation. However, changes in ACS may also occur in samples under refrigeration. OBJECTIVE: To analyze the influence of refrigeration at 2 to 8ºC on the storage of urine samples within 24 hours. MATERIAL AND METHOD: A total of 80 urine samples were selected from patients admitted at Universidade Federal de Juiz de Fora (UFJF university hospital, which were tested for ACS at room temperature and stored under refrigeration for 6, 12 and 24 hours. RESULTS: The results showed that refrigeration proved to be effective when compared to samples kept at room temperature, inasmuch as the physical, chemical, microbial and cellularity features were preserved. Nevertheless, crystalluria was present after a 6- hour storage period. CONCLUSION: The tests revealed that cooling preserved cellularity and chemical characteristics of urine samples for up to 12 hours. Nonetheless, the precipitation of crystals was evident in this storage method. Thus, the possible consequences of storing urine samples for ACS test under these conditions should be included in the analysis report.

  9. Effect of gamma-irradiation and refrigerated storage on mold growth and keeping quality of strawberry (Fragaria sp) cv 'Confitura'

    International Nuclear Information System (INIS)

    Hussain, P.R.; Meena, R.S.; Dar, M.A.; Wani, A.M.; Mir, M.A.; Shafi, F.

    2007-01-01

    Gamma-irradiation of fresh matured strawberries at 0.5-2.0 kGy and storage under ambient and refrigerated conditions was tested for delaying the mold appearance and extension of storage life. Radiation dose of 2.0 kGy was effective in extending the storage life of fresh strawberries by 2 days under ambient conditions. Samples irradiated at 1.5 and 2.0 kGy followed by refrigerated storage delayed the mold growth significantly (p≤0.05) and extended the storage life by 8 days. (author)

  10. Computer simulation with TRNSYS for a mobile refrigeration system incorporating a phase change thermal storage unit

    International Nuclear Information System (INIS)

    Liu, Ming; Saman, Wasim; Bruno, Frank

    2014-01-01

    Highlights: • A mobile refrigeration system incorporating phase change thermal storage was simulated using TRNSYS. • A TRNSYS component of a phase change thermal storage unit was created and linked to other components from TRNSYS library. • The temperature in the refrigerated space can be predicted using this TRNSYS model under various conditions. • A mobile refrigeration system incorporating PCM and an off-peak electric driven refrigeration unit is feasible. • The phase change material with the lowest melting temperature should be selected. - Abstract: This paper presents a new TRNSYS model of a refrigeration system incorporating phase change material (PCM) for mobile transport. The PCTSU is charged by an off-vehicle refrigeration unit and the PCM provides cooling when discharging and the cooling released is utilized to cool down the refrigerated space. The advantage of this refrigeration system compared to a conventional system is that it consumes less energy and produces significantly lower greenhouse gas emissions. A refrigeration system for a typical refrigerated van is modelled and simulations are performed with climatic data from four different locations. The main components of the TRNSYS model are Type 88 (cooling load estimation) and Type 300 (new PCTSU component), accompanied by other additional components. The results show that in order to maintain the temperature of the products at −18 °C for 10 h, a total of 250 kg and 390 kg of PCM are required for no door opening and 20 door openings during the transportation, respectively. In addition, a parametric study is carried out to evaluate the effects of location, size of the refrigerated space, number of door openings and melting temperature of the PCM on the thermal performance

  11. Enhancement of refrigerated storage of fishery products using gamma irradiation

    International Nuclear Information System (INIS)

    Lewis, N.F.; Ghadi, S.V.; Doke, S.N.; Venugopal, V.; Alur, M.D.

    1977-01-01

    A processe combining gamma radiation treatment with refrigeration has been suggested for better utilization of sea-foods of which large quantities will be available for processing after the implementation of the expansion programme of the fishing industry in India and the present capacity of refrigeration industry may be found to be inadequate to meet the demands of the expanded fishing industry. Gamma irradiation in the range of 0.1-0.25 Mrad enhances 2-3 fold storage life of refrigerated sea-foods. Low dose radiation treatment inactivates the gram-negative bacteria, the main source of sea-food spoilage, but not C. botulinum the growth of which is inhibited by the gram-negative bacteria in unirradiated sea-foods. Care has, therefore, to be taken to use a radiation dose which does not totally eliminate these bacteria so that a small percentage which survives leads to terminal spoilage and rejection of sea-foods even before C. botulinum produces toxins thus avoiding food poisoning. (M.G.B.)

  12. ABOUT THE GENERAL CONCEPT OF THE UNIVERSAL STORAGE SYSTEM AND PRACTICE-ORIENTED DATA PROCESSING

    Directory of Open Access Journals (Sweden)

    L. V. Rudikova

    2017-01-01

    Full Text Available Approaches evolution and concept of data accumulation in warehouse and subsequent Data Mining use is perspective due to the fact that, Belarusian segment of the same IT-developments is organizing. The article describes the general concept for creation a system of storage and practice-oriented data analysis, based on the data warehousing technology. The main aspect in universal system design on storage layer and working with data is approach uses extended data warehouse, based on universal platform of stored data, which grants access to storage and subsequent data analysis different structure and subject domains have compound’s points (nodes and extended functional with data structure choice option for data storage and subsequent intrasystem integration. Describe the universal system general architecture of storage and analysis practice-oriented data, structural elements. Main components of universal system for storage and processing practice-oriented data are: online data sources, ETL-process, data warehouse, subsystem of analysis, users. An important place in the system is analytical processing of data, information search, document’s storage and providing a software interface for accessing the functionality of the system from the outside. An universal system based on describing concept will allow collection information of different subject domains, get analytical summaries, do data processing and apply appropriate Data Mining methods and algorithms.

  13. Shelf-life extension of Pacific white shrimp using algae extracts during refrigerated storage.

    Science.gov (United States)

    Li, Yingchang; Yang, Zhongyan; Li, Jianrong

    2017-01-01

    Shrimp is a low-fat, high-protein aquatic product, and is susceptible to spoilage during storage. To establish an effective method for the quality control of Pacific white shrimp, the effects of polyphenols (PP) and polysaccharides (PS) from Porphyra yezoensis on the quality of Pacific white shrimp were assessed during refrigerated storage. Pacific white shrimp samples were treated with 5 g L -1 polyphenols, and 8 g L -1 polysaccharides, then stored at 4 ± 1 °C for 8 days. All samples were subjected to measurement of total viable count (TVC), pH, total volatile basic nitrogen (TVB-N), K-value, thiobarbituric acid (TBA), polyphenol oxidase (PPO) activity, and were also assessed by sensory evaluation. The results showed that PP, PS, and the mixture of polyphenols and polysaccharides (PP+PS) could inhibit the increase of total volatile basic nitrogen (TVB-N), thiobarbituric acid (TBA) and K-value, and reduce total viable count (TVC) compared with the control group. PP could also inhibit polyphenol oxidase (PPO) activity. Sensory evaluation proved the efficacy of PP and PS by maintaining the overall quality of Pacific white shrimp during refrigerated storage. Moreover, PP+PS could extend the shelf-life of shrimp by 3-4 days compared with the control group. PP+PS could more effectively maintain quality and extend shelf-life during refrigerated storage. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  14. Modeling of thermodynamic properties of refrigerant/absorbent couples using data mining process

    International Nuclear Information System (INIS)

    Sencan, Arzu

    2007-01-01

    In this paper, in order to determine thermodynamic properties of two alternative refrigerant/absorbent couples (methanol/LiBr and methanol/LiCl), a data mining process was used. These fluid couples can be used in absorption heat pump systems, and their main advantage is that they do not cause ozone depletion. In order to train the network, limited experimental measurements were used as training and test data. In the present study, linear regression (LR), pace regression (PR), sequential minimal optimization (SMO), M5 model tree, M5'Rules and back propagation neural network (BPNN) models are applied within the data mining process for determining the specific volume of the methanol/LiBr and methanol/LiCl fluid couples. The best result was obtained by using the back propagation model. A new formulation is presented for determination of the specific volumes of the two refrigerant/absorbent couples. The use of this new formulation, which can be employed with any programming language or spreadsheet program for estimation of the specific volumes of fluid couples, as described in this paper, may make the use of dedicated BPNN software unnecessary

  15. Concept for an ultimate storage facility for heat-generating radioactive waste in clay stone in Germany

    International Nuclear Information System (INIS)

    Bollingerfehr, Wilhelm; Poehler, Matthias

    2010-01-01

    According to the German reference ultimate storage concept heat-generating radioactive waste from the operation of nuclear power stations should be stored permanently maintenance-free and in a non-recoverable manner in a salt formation. Within the framework of investigations into the utilisation of alternative host rocks a concept for an ultimate storage facility in clay stone was developed in an R and D project. For this purpose all important aspects of the design, development, operation and shutdown were taken into account for a model region in northern Germany. It was established that storage in 50 m deep vertical boreholes in a mine at a depth of about 350 m appears to be the most practical solution for an ultimate storage facility in clay stone. Compared to the reference concept in salt an ultimate storage facility in clay stone requires solid support of all mine openings with steel arches or shotcrete. Because of the lower maximum permissible temperature in the backfilling material (bentonite) the area required for the ultimate storage facility is about five times larger. A period of more than 100 years is estimated from survey to shutdown. (orig.)

  16. Changes in Meat Quality Characteristics of the Sous-vide Cooked Chicken Breast during Refrigerated Storage.

    Science.gov (United States)

    Hong, Go-Eun; Kim, Ji-Han; Ahn, Su-Jin; Lee, Chi-Ho

    2015-01-01

    This study was performed to investigate the changes in meat quality characteristics of the sous vide cooked chicken breast during refrigerated storage at 4℃ for 14 d between before and after sous-vide cooking. Cooking loss and shear force were significantly increased, whereas expressible drip was significantly decreased along with reduction in the water holding capacity in both of two groups. Redness of meat juice was significantly (p<0.05) increased during storage, and considerably increased in the refrigerated samples after sous-vide cooked at the 7 to 10 d. The thiobarbituric acid reactive substances (TBARS) was significantly increased and was higher in the refrigerator stored chicken breast samples after sous-vide cooking. The volatile basic nitrogen (VBN) value was significantly increased in both groups, but the VBN value of the stored raw meat sample before sous-vide cooking was increased at an early storage, while the VBN value of the stored sample after sous-vide cooking was increased gradually in this study. Total viable counts and coliform counts were significantly decreased during storage, and coliforms were not detected after 7 d of storage in both groups. Salmonella spp. was not detected during the whole studied period. The outcome of this research can provide preliminary data that could be used to apply for further study of chicken breast using sous-vide cooking method that could be attractive to consumers.

  17. Modification of a liquid hydrogen tank for integrated refrigeration and storage

    Science.gov (United States)

    Swanger, A. M.; Jumper, K. M.; Fesmire, J. E.; Notardonato, W. U.

    2015-12-01

    The modification and outfitting of a 125,000-liter liquid hydrogen tank was performed to provide integrated refrigeration and storage capability. These functions include zero boil-off, liquefaction, and densification and therefore require provisions for sub-atmospheric tank pressures within the vacuum-jacketed, multilayer insulated tank. The primary structural modification was to add stiffening rings inside the inner vessel. The internal stiffening rings were designed, built, and installed per the ASME Boiler and Pressure Vessel Code, Section VIII, to prevent collapse in the case of vacuum jacket failure in combination with sub-atmospheric pressure within the tank. For the integrated refrigeration loop, a modular, skeleton-type heat exchanger, with refrigerant temperature instrumentation, was constructed using the stiffening rings as supports. To support the system thermal performance testing, three custom temperature rakes were designed and installed along the 21-meter length of the tank, once again using rings as supports. The temperature rakes included a total of 20 silicon diode temperature sensors mounted both vertically and radially to map the bulk liquid temperature within the tank. The tank modifications were successful and the system is now operational for the research and development of integrated refrigeration technology.

  18. Food Service Refrigerators and Food Service Storage Freezers. Standard No. 7, Revised April 1966.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI.

    This standard covers the sanitation and performance requirements for new food service refrigerators and food service storage freezers of the type generally used in the food service industry. It covers cabinets operating in the freezers, above or below freezing temperature, designed for the storage or display of varieties of food products. Topics…

  19. Study of mined storage caverns

    International Nuclear Information System (INIS)

    1975-06-01

    All available information concerning 75 mined storage caverns as well as the investigative techniques utilized to determine the feasibility of a cavern site is presented. Potential new storage caverns may be for products such as high or low vapor pressure petroleum products, other chemical products, aid industrial or nuclear waste

  20. 2017 German refrigeration and air conditioning meeting. Proceedings

    International Nuclear Information System (INIS)

    2017-01-01

    This year's lecture programme includes 117 presentations in the five working departments of DKV and 10 lectures at the special event ''Energy-efficient air conditioning in data centres''. The main topics in the respective departments were: (1) Cryogenics: Space applications; Cryogenic plants; Cryomedicine and cryobiology; Components, developments; Processes and plants; Valves, design. (2) Basics: Evaporation, material values; evaporation, condensation; absorption; adsorption, latent storage; cycle simulation. (3) Components: CO 2 plant engineering and components; refrigerants; process control, adsorption, sublimation and storage technology; refrigerating machine oils, heat exchangers and corrosion; components 4.0, sensors and control technology; simulation of plant processes. (4) Cold application: Application; Application / Natural Refrigerants; Mobile Applications Car; Mobile Applications; Supermarket / Efficiency; Optimization / Efficiency. (5) Air conditioning and heat pump applications: load shifting, smart home, flexibility; heat sources and industrial heat pumps; modelling, simulations; energy concepts heat pumps and photovoltaics; monitoring, evaluation; technology trends / working materials. Six papers are separately analyzed for this database. [de

  1. Application of a Surimi-Based Coating to Improve the Quality Attributes of Shrimp during Refrigerated Storage.

    Science.gov (United States)

    Sharaf Eddin, Abdulhakim; Tahergorabi, Reza

    2017-09-05

    Shrimp is a popular seafood throughout the world. However, shrimp is highly perishable due to biochemical, microbiological, or physical changes during postmortem storage. In this study, the effect of a surimi-based coating with and without montmorillonite (MMT) nanoclay on shrimp quality was evaluated during eight days of refrigerator storage. Use of a surimi-based coating resulted in reductions of aerobic plate counts (APC) up to 2 log units. The combined effect of the MMT and coating was observed. Surimi-based coating with MMT resulted in lower APC ( p coating with MMT to the shrimp samples improved sensory quality and delayed lipid oxidation and color deterioration during storage time. In general, better texture was observed when coating was applied either with or without MMT. This study suggests that surimi-based coating may improve the quality of shrimp during refrigerated storage.

  2. Reduction of pasteurization temperature leads to lower bacterial outgrowth in pasteurized fluid milk during refrigerated storage: a case study.

    Science.gov (United States)

    Martin, N H; Ranieri, M L; Wiedmann, M; Boor, K J

    2012-01-01

    Bacterial numbers over refrigerated shelf-life were enumerated in high-temperature, short-time (HTST) commercially pasteurized fluid milk for 15 mo before and 15 mo after reducing pasteurization temperature from 79.4°C (175°F) [corrected] to 76.1°C (169°F). Total bacterial counts were measured in whole fat, 2% fat, and fat-free milk products on the day of processing as well as throughout refrigerated storage (6°C) at 7, 14, and 21 d postprocessing. Mean total bacterial counts were significantly lower immediately after processing as well as at 21 d postprocessing in samples pasteurized at 76.1°C versus samples pasteurized at 79.4°C. In addition to mean total bacterial counts, changes in bacterial numbers over time (i.e., bacterial growth) were analyzed and were lower during refrigerated storage of products pasteurized at the lower temperature. Lowering the pasteurization temperature for unflavored fluid milk processed in a commercial processing facility significantly reduced bacterial growth during refrigerated storage. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Contrast data mining concepts, algorithms, and applications

    CERN Document Server

    Dong, Guozhu

    2012-01-01

    A Fruitful Field for Researching Data Mining Methodology and for Solving Real-Life Problems Contrast Data Mining: Concepts, Algorithms, and Applications collects recent results from this specialized area of data mining that have previously been scattered in the literature, making them more accessible to researchers and developers in data mining and other fields. The book not only presents concepts and techniques for contrast data mining, but also explores the use of contrast mining to solve challenging problems in various scientific, medical, and business domains. Learn from Real Case Studies

  4. Long-term experience in salt mining and experience in salt mine decommissioning - a chance for ultimate storage?

    International Nuclear Information System (INIS)

    Sitz, P.; Rauche, H.

    2003-01-01

    The author discusses similarities between salt mining and ultimate storage and the possibility of using abandoned salt mines as ultimate storage site. He states that with all the numeric prediction tools now available, expert knowledge of mining engineers is still indispensable [de

  5. CONCEPT OF AUTOMATIC CONTROL SYSTEM FOR IMPROVING THE EFFICIENCY OF THE ABSORPTION REFRIGERATING UNITS

    Directory of Open Access Journals (Sweden)

    O. Titlova

    2016-12-01

    Full Text Available The general concept of the automatic control systems constructing for increasing the efficiency of the artificial cold production process in the absorption refrigerating units is substantiated. The described automatic control systems provides necessary degree of the ammonia vapor purification from the water in all absorption refrigerating units modes and minimizes heat loss from the dephlegmator surface.

  6. Geological Feasibility of Underground Oil Storage in Jintan Salt Mine of China

    Directory of Open Access Journals (Sweden)

    Xilin Shi

    2017-01-01

    Full Text Available A number of large underground oil storage spaces will be constructed in deep salt mines in China in the coming years. According to the general geological survey, the first salt cavern oil storage base of China is planned to be built in Jintan salt mine. In this research, the geological feasibility of the salt mine for oil storage is identified in detail as follows. (1 The characteristics of regional structure, strata sediment, and impermeable layer distribution of Jintan salt mine were evaluated and analyzed. (2 The tightness of cap rock was evaluated in reviews of macroscopic geology and microscopic measuring. (3 According to the geological characteristics of Jintan salt mine, the specific targeted formation for building underground oil storage was chosen, and the sealing of nonsalt interlayers was evaluated. (4 Based on the sonar measuring results of the salt caverns, the characteristics of solution mining salt caverns were analyzed. In addition, the preferred way of underground oil storage construction was determined. (5 Finally, the results of closed well observation in solution mining salt caverns were assessed. The research results indicated that Jintan salt mine has the basic geological conditions for building large-scale underground oil storage.

  7. Zero boil-off methods for large-scale liquid hydrogen tanks using integrated refrigeration and storage

    Science.gov (United States)

    Notardonato, W. U.; Swanger, A. M.; E Fesmire, J.; Jumper, K. M.; Johnson, W. L.; Tomsik, T. M.

    2017-12-01

    NASA has completed a series of tests at the Kennedy Space Center to demonstrate the capability of using integrated refrigeration and storage (IRAS) to remove energy from a liquid hydrogen (LH2) tank and control the state of the propellant. A primary test objective was the keeping and storing of the liquid in a zero boil-off state, so that the total heat leak entering the tank is removed by a cryogenic refrigerator with an internal heat exchanger. The LH2 is therefore stored and kept with zero losses for an indefinite period of time. The LH2 tank is a horizontal cylindrical geometry with a vacuum-jacketed, multilayer insulation system and a capacity of 125,000 liters. The closed-loop helium refrigeration system was a Linde LR1620 capable of 390W cooling at 20K (without any liquid nitrogen pre-cooling). Three different control methods were used to obtain zero boil-off: temperature control of the helium refrigerant, refrigerator control using the tank pressure sensor, and duty cycling (on/off) of the refrigerator as needed. Summarized are the IRAS design approach, zero boil-off control methods, and results of the series of zero boil-off tests.

  8. A first study comparing preservation of a ready-to-eat soup under pressure (hyperbaric storage) at 25°C and 30°C with refrigeration.

    Science.gov (United States)

    Moreira, Sílvia A; Fernandes, Pedro A R; Duarte, Ricardo; Santos, Diana I; Fidalgo, Liliana G; Santos, Mauro D; Queirós, Rui P; Delgadillo, Ivonne; Saraiva, Jorge A

    2015-11-01

    Hyperbaric storage (HS), storage under pressure at 25°C and 30°C, of a ready-to-eat (RTE) soup was studied and compared with refrigeration. Soup was stored at different time (4 and 8 h), temperature (4°C, 25°C, and 30°C), and pressure (0.1, 100, and 150 MPa) conditions, to compare microbial loads and physicochemical parameters. HS resulted in similar (microbial growth inhibition) to better (microbial inactivation) results compared to refrigeration, leading to equal and lower microbial loads, respectively, at the end of storage. Lower/higher pressure (100 vs. 150 MPa) and shorter/longer storage times (4 vs. 8 h) resulted in more pronounced microbial growth inhibition/microbial inactivation. Aerobic mesophiles showed less susceptibility to HS, compared to Enterobacteriaceae and yeast and molds. HS maintained generally the physicochemical parameters at values similar to refrigeration. Thus, HS with no need for temperature control throughout storage and so basically energetically costless, is a potential alternative to refrigeration.

  9. Physicochemical and microbiological changes during the refrigerated storage of lamb loins sous-vide cooked at different combinations of time and temperature.

    Science.gov (United States)

    Roldán, Mar; Antequera, Teresa; Hernández, Alejandro; Ruiz, Jorge

    2015-10-01

    This study aimed to determine the influence of cooking temperature (either 60 ℃ or 80 ℃) and time (6 h or 24 h) on the physicochemical (weight loss, moisture content, instrumental color, instrumental texture, lipid and protein oxidation) and microbiological changes underwent by sous-vide cooked lamb loins during refrigerated storage for 30 days. There was a slight trend to decreasing weight losses in some of the cooking treatments, but only in samples cooked at 60 ℃ for 6 h it was paralleled with an increase in moisture content. The only noteworthy oxidative change was a marked decrease in conjugated dienes after two weeks of storage in samples cooked at 80 ℃ for 24 h. Neither instrumental texture nor color showed noticeable variations during the storage. Microbial population remained quite low during the whole refrigerated storage. Overall, most of the studied parameters showed only scarce changes throughout 30 days of refrigerated storage that most likely would not influence the quality of sous-vide cooked loin lambs. © The Author(s) 2014.

  10. Effect of slaughter methods on the quality of Chilean jack mackerel (Trachurus murphyi) during refrigerated storage.

    Science.gov (United States)

    Lyu, Fei; Huang, Rui-Ji; Liu, Lin; Zhou, Xuxia; Ding, Yu-Ting

    2015-03-01

    The main objective of this study was to assess the influence of slaughter methods on the quality of Chilean jack mackerel (Trachurus murphyi) during refrigerated storage on board. Fishes were slaughtered by asphyxia in air (AA), asphyxia in ice water (AI) or stunning fish heads (SH), and the rigor mortis, pH, total volatile basic nitrogen (TVB-N), trimethylamine (TMA), 2-thiobarbituric acid reactive substances (TBARS) and sensory properties for the fishes were analyzed. On day 0, Chilean jack mackerel samples of AI group displayed higher pH values than those of AA and SH groups. TVB-N, TMA and TBARS values of all samples increased with the storage time, and these values of AI had a lower increase than AA and SH. Moreover, samples of AI had a better sensory score than AA and SH during storage. It can be concluded that slaughter method of asphyxia in ice water for Chilean jack mackerel exhibit the better efficiency on maintaining the fish quality during refrigerated storage on board.

  11. Design and Performance Analysis of a Biodiesel Engine Driven Refrigeration System for Vaccine Storage

    Directory of Open Access Journals (Sweden)

    K Kamsuk

    2013-06-01

    Full Text Available A compact, stand-alone, refrigeration module powered by a small biodiesel engine for vaccine storage in rural use was proposed. The engine was of single cylinder, four-stroke, directinjection with displacement of 0.296 cm3 and compression ratio of 20:1. The refrigeration system was modified from an automotive vapor compression system. The system performance was analytically investigated. From the simulation, it was found to have acceptable operation over a range of speeds and loads. Performance of the system in terms of fuel consumption and torque tended to decrease with an increase in engine speed. The modular system was able to operate at cooling loads above 4.6 kW, with proper speed ratio between the engine and the compressor. Overall, primary energy ratio of the refrigeration was found to be maximum at 0.54.

  12. A Review of Extra-Terrestrial Mining Concepts

    Science.gov (United States)

    Mueller, R. P.; van Susante, P. J.

    2012-01-01

    Outer space contains a vast amount of resources that offer virtually unlimited wealth to the humans that can access and use them for commercial purposes. One of the key technologies for harvesting these resources is robotic mining of regolith, minerals, ices and metals. The harsh environment and vast distances create challenges that are handled best by robotic machines working in collaboration with human explorers. Humans will benefit from the resources that will be mined by robots. They will visit outposts and mining camps as required for exploration, commerce and scientific research, but a continuous presence is most likely to be provided by robotic mining machines that are remotely controlled by humans. There have been a variety of extra-terrestrial robotic mining concepts proposed over the last 40 years and this paper will attempt to summarize and review concepts in the public domain (government, industry and academia) to serve as an informational resource for future mining robot developers and operators. The challenges associated with these concepts will be discussed and feasibility will be assessed. Future needs associated with commercial efforts will also be investigated.

  13. Changes of microbial spoilage, lipid-protein oxidation and physicochemical properties during post mortem refrigerated storage of goat meat.

    Science.gov (United States)

    Sabow, Azad Behnan; Sazili, Awis Qurni; Aghwan, Zeiad Amjad; Zulkifli, Idrus; Goh, Yong Meng; Ab Kadir, Mohd Zainal Abidin; Nakyinsige, Khadijah; Kaka, Ubedullah; Adeyemi, Kazeem Dauda

    2016-06-01

    Examined was the effect of post mortem refrigerated storage on microbial spoilage, lipid-protein oxidation and physicochemical traits of goat meat. Seven Boer bucks were slaughtered, eviscerated and aged for 24 h. The Longissimus lumborum (LL) and Semitendinosus (ST) muscles were excised and subjected to 13 days post mortem refrigerated storage. The pH, lipid and protein oxidation, tenderness, color and drip loss were determined in LL while microbiological analysis was performed on ST. Bacterial counts generally increased with increasing aging time and the limit for fresh meat was reached at day 14 post mortem. Significant differences were observed in malondialdehyde (MDA) content at day 7 of storage. The thiol concentration significantly reduced as aging time increased. The band intensities of myosin heavy chain (MHC) and troponin-T significantly decreased as storage progressed, while actin remained relatively stable. After 14 days of aging, tenderness showed significant improvement while muscle pH and drip loss reduced with increase in storage time. Samples aged for 14 days had higher lightness (P goat meat. © 2016 Japanese Society of Animal Science.

  14. Development of a Battery-Free Solar Refrigerator

    Science.gov (United States)

    Ewert, Michael K.; Bergeron, David J., III

    2000-01-01

    Recent technology developments and a systems engineering design approach have led to the development of a practical battery-free solar refrigerator as a spin-off of NASA's aerospace refrigeration research. Off-grid refrigeration is a good application of solar photovoltaic (PV) power if thermal storage is incorporated and a direct connection is made between the cooling system and the PV panel. This was accomplished by integrating water as a phase-change material into a well insulated refrigerator cabinet and by developing a microprocessor based control system that allows direct connection of a PV panel to a variable speed compressor. This second innovation also allowed peak power-point tracking from the PV panel and elimination of batteries from the system. First a laboratory unit was developed to prove the concept and then a commercial unit was produced and deployed in a field test. The laboratory unit was used to test many different configurations including thermoelectric, Stirling and vapor compression cooling systems. The final configuration used a vapor compression cooling cycle, vacuum insulation, a passive condenser, an integral evaporator/ thermal storage tank, two 77 watt PV panels and the novel controller mentioned above. The system's only moving part was the variable speed BD35 compressor made by Danfoss. The 365 liter cabinet stayed cold with as little as 274 watt-hours per day average PV power. Battery-free testing was conducted for several months with very good results. The amount of thermal storage, size of compressor and power of PV panels connected can all be adjusted to optimize the design for a given application and climate. In the commercial unit, the high cost of the vacuum insulated refrigerator cabinet and the stainless steel thermal storage tank were addressed in an effort to make the technology commercially viable. This unit started with a 142 liter, mass-produced chest freezer cabinet that had the evaporator integrated into its inner walls

  15. Enhanced electrocaloric analysis and energy-storage performance of lanthanum modified lead titanate ceramics for potential solid-state refrigeration applications.

    Science.gov (United States)

    Zhang, Tian-Fu; Huang, Xian-Xiong; Tang, Xin-Gui; Jiang, Yan-Ping; Liu, Qiu-Xiang; Lu, Biao; Lu, Sheng-Guo

    2018-01-10

    The unique properties and great variety of relaxer ferroelectrics make them highly attractive in energy-storage and solid-state refrigeration technologies. In this work, lanthanum modified lead titanate ceramics are prepared and studied. The giant electrocaloric effect in lanthanum modified lead titanate ceramics is revealed for the first time. Large refrigeration efficiency (27.4) and high adiabatic temperature change (1.67 K) are achieved by indirect analysis. Direct measurements of electrocaloric effect show that reversible adiabatic temperature change is also about 1.67 K, which exceeds many electrocaloric effect values in current direct measured electrocaloric studies. Both theoretical calculated and direct measured electrocaloric effects are in good agreements in high temperatures. Temperature and electric field related energy storage properties are also analyzed, maximum energy-storage density and energy-storage efficiency are about 0.31 J/cm 3 and 91.2%, respectively.

  16. Prior frozen storage enhances the effect of edible coatings against Listeria monocytogenes on cold-smoked salmon during subsequent refrigerated storage.

    Science.gov (United States)

    Ye, M; Neetoo, H; Chen, H

    2011-10-01

    Listeria monocytogenes is a major safety concern for ready-to-eat foods. The overall objective of this study was to investigate whether prior frozen storage could enhance the efficacy of edible coatings against L. monocytogenes on cold-smoked salmon during subsequent refrigerated storage. A formulation consisting of sodium lactate (SL, 1·2-2·4%) and sodium diacetate (SD, 0·125-0·25%) or 2·5% Opti.Form (a commercial formulation of SL and SD) was incorporated into each of five edible coatings: alginate, κ-carrageenan, pectin, gelatin and starch. The coatings were applied onto the surface of cold-smoked salmon slices inoculated with L. monocytogenes at a level of 500 CFU cm⁻². In the first phase, the slices were first frozen at -18°C for 6 days and stored at 22°C for 6 days. Alginate, gelatin and starch appeared to be the most effective carriers. In the second phase, cold-smoked salmon slices were inoculated with L. monocytogenes, coated with alginate, gelatin or starch with or without the antimicrobials and stored frozen at -18°C for 12 months. Every 2 months, samples were removed from the freezer and kept at 4°C for 30 days. Prior frozen storage at -18°C substantially enhanced the antilisterial efficacy of the edible coatings with or without antimicrobials during the subsequent refrigerated storage. Plain coatings with ≥ 2 months frozen storage and antimicrobial edible coatings represent an effective intervention to inhibit the growth of L. monocytogenes on cold-smoked salmon. This study demonstrates the effectiveness of the conjunct application of frozen storage and edible coatings to control the growth of L. monocytogenes to enhance the microbiological safety of cold-smoked salmon. © 2011 The Authors. Journal of Applied Microbiology © 2011 The Society for Applied Microbiology.

  17. Experimental investigation of the dynamic behavior of a large-scale refrigeration – PCM energy storage system. Validation of a complete model

    International Nuclear Information System (INIS)

    Wu, Jing; Tremeac, Brice; Terrier, Marie-France; Charni, Mehdi; Gagnière, Emilie; Couenne, Françoise; Hamroun, Boussad; Jallut, Christian

    2016-01-01

    In the area of buildings refrigeration, the use of thermal energy storages coupled with heat pumps is a significant way for reducing the operating costs and optimizing the design of equipment. In this paper, a prototype of large-scale refrigeration - PCM (Phase Change Material) energy storage system is described, from which experimental results on transient behavior are obtained. A dynamic model for transient simulation of the coupled system is presented. The fluid flows through the heat exchangers and the storage tank are represented by a cascade of Continuous Stirred Tank Reactors (CSTRs). Switching procedures between different model configurations associated to phase transitions within heat exchangers and PCM storage tank are mathematically performed by matrix operations. The compressor, the expansion valve and the pressure drop across the evaporator are represented by static models based on empirical correlations. A PI controller for the expansion valve opening is integrated in the heat pump model to maintain the superheat at evaporator exit. The model is validated by a complete and detailed comparison between simulation and experimental results. - Highlights: • Experimental investigation of a refrigeration-PCM storage system is presented. • A detailed dynamic model for the coupled system is proposed. • Fluid flows in heat exchangers and PCM storage are represented by a cascade of CSTRs. • Phase transitions events according to time and space within heat exchangers and PCM storage are considered in the model. • Complete comparisons between experimental and simulation results are carried out.

  18. A Review of Extra-Terrestrial Mining Robot Concepts

    Science.gov (United States)

    Mueller, Robert P.; Van Susante, Paul J.

    2011-01-01

    Outer space contains a vast amount of resources that offer virtually unlimited wealth to the humans that can access and use them for commercial purposes. One of the key technologies for harvesting these resources is robotic mining of regolith, minerals, ices and metals. The harsh environment and vast distances create challenges that are handled best by robotic machines working in collaboration with human explorers. Humans will benefit from the resources that will be mined by robots. They will visit outposts and mining camps as required for exploration, commerce and scientific research, but a continuous presence is most likely to be provided by robotic mining machines that are remotely controlled by humans. There have been a variety of extra-terrestrial robotic mining concepts proposed over the last 100 years and this paper will attempt to summarize and review concepts in the public domain (government, industry and academia) to serve as an informational resource for future mining robot developers and operators. The challenges associated with these concepts will be discussed and feasibility will be assessed. Future needs associated with commercial efforts will also be investigated.

  19. Studies on the Effect of Pomegranate Rind Powder Extract as Natural Antioxidant in Chicken Meat Balls During Refrigerated Storage

    Directory of Open Access Journals (Sweden)

    Savala Chandralekha

    2012-04-01

    Full Text Available Trials were conducted to study the effect of pomegranate rind powder extract as natural antioxidant in chicken meat balls during refrigerated storage. Significantly (p<0.05 lower values for cooking loss, pH and 2-thiobarbituric acid (2-TBARS values and higher values for emulsion stability were obtained due to the incorporation of pomegranate rind powder extract at 5 percent level followed by 2.5 percent level than the other treatments. There was a significant (p<0.05 increase in cooking loss, pH, 2-TBARS values and free fatty acid content as the storage period progressed from 0 to 8 days, however emulsion stability of chicken meat balls decreased significantly (p<0.05 during the course of refrigeration. Microbial quality evaluation revealed that chicken meat balls incorporated with pomegranate rind powder extract at 5 percent level had significantly (p<0.05 lower standard plate count during refrigerated storage and a significant (p<0.05 increase in microbial load was observed. Organoleptic evaluation indicated that addition of pomegranate rind powder extract at 5 and 2.5 percent levels to chicken meat balls registered significantly (p<0.05 higher sensory scores for various eating quality attributes than the other treatments. However there was a significant (p<0.05 in all the organoleptic attributes of the product as the storage period increased.

  20. Shuttle Kit Freezer Refrigeration Unit Conceptual Design

    Science.gov (United States)

    Copeland, R. J.

    1975-01-01

    The refrigerated food/medical sample storage compartment as a kit to the space shuttle orbiter is examined. To maintain the -10 F in the freezer kit, an active refrigeration unit is required, and an air cooled Stirling Cycle refrigerator was selected. The freezer kit contains two subsystems, the refrigeration unit, and the storage volume. The freezer must provide two basic capabilities in one unit. One requirement is to store 215 lbs of food which is consumed in a 30-day period by 7 people. The other requirement is to store 128.3 lbs of medical samples consisting of both urine and feces. The unit can be mounted on the lower deck of the shuttle cabin, and will occupy four standard payload module compartments on the forward bulkhead. The freezer contains four storage compartments.

  1. Mined salt storage feasibility: Engineering study report

    International Nuclear Information System (INIS)

    1987-07-01

    This study addresses a method of eliminating the surface storage of mined salt at the Deaf Smith repository site. It provides rough estimates of the logistics and costs of transporting 3.7 million tons of salt from the repository to the salt disposal site near Carlsbad, New Mexico and returning it to the repository for decommissioning backfill. The study assumes that a railcar/truck system will be installed and that the excavated salt will be transported from the repository to an existing potash mine located near Carlsbad, New Mexico approximately 300 miles from the repository. The 3.7 million tons of salt required for repository decommissioning backfill can be stored in the potash mines along with the excess salt, with no additional capital costs required for either a railcar or a truck transportation system. The capital cost for facilities to reclaim the 3.7 million tons of salt from the potash mine is estimated to be $4,400,000 with either a rail or truck transportation system. Segregating the 3.7 million tons of backfill salt in a surface storage area at the potash mine requires a capital cost of $13,900,000 with a rail system or $11,400,000 with a truck system. Transportation costs are estimated at $0.08/ton-mile for rail and $0.13/ton-mile for truck. 2 figs., 5 tabs

  2. QUALITY OF MINIMALLY PROCESSED ‘FUJI’ APPLE UNDER REFRIGERATED STORAGE AND TREATMENT WITH ADDITIVES

    Directory of Open Access Journals (Sweden)

    MARINES BATALHA MORENO

    Full Text Available ABSTRACT The aim of this study was to evaluate the ability to prolong the useful life of the minimally processed ‘Fuji’ apple by applying the individual or combined additives (L-cysteine chloride, L-ascorbic acid and calcium chloride and to determine the appropriate period of storage of the whole fruit to perform the minimum processing. The experimental design was completely randomized in three-factor design with three replications. Factor A was composed of storage periods of whole apples, pre-processing, in cold chambers (20, 78, 138 and 188 days; the factor B was represented by storage periods minimum post-processing, simulating shelf life (3, 6, 9 and 12 days, and factor C was represented by chemical additives (distilled water, as control, 0.5% L-cysteine chloride, 1% L-ascorbic acid, 0.5% L-cysteine chloride along with 1% calcium chloride and 1% L-ascorbic acid together with 1% calcium chloride. The evaluated dependent variables were pulp color (L* and hº, soluble solids, titratable acidity, content of phenolic compounds, antioxidant capacity and quantification of polyphenol oxidase. In addition, was analyzed the presence or absence of Salmonella sp. and Escherichia coli. The prolongation of the storage time of ‘Fuji’ apples in a refrigerated atmosphere promotes increased susceptibility to browning and softening after processing from 78 days of storage. The use of additives in the process, helps prevent these problems, especially when combined 0.5% L-cysteine chloride with 1% calcium chloride, achieving an excellent conservation in refrigerated shelf up to 6 days. From a microbiological aspect, minimally processed apples are toxicologically safe.

  3. Effect of pomegranate peel extract on lipid and protein oxidation in beef meatballs during refrigerated storage.

    Science.gov (United States)

    Turgut, Sebahattin Serhat; Soyer, Ayla; Işıkçı, Fatma

    2016-06-01

    Antioxidant effect of pomegranate peel extract (PE) to retard lipid and protein oxidation was investigated in meatballs during refrigerated storage at 4±1°C. Concentrated lyophilised water extract of pomegranate peel was incorporated into freshly minced beef meat at 0.5% and 1% concentrations and compared with 0.01% butylated hydroxytoluene (BHT) as a reference and control (without any antioxidant). PE showed high phenolic content and antioxidant activity. In PE added samples, thiobarbituric acid reactive substances (TBARS) value, peroxide formation, loss of sulfhydryl groups and formation of protein carbonyls were lower than control (Pmeatballs prolonged the refrigerated storage up to 8 days. Addition of both 0.5 and 1% PE in meatballs reduced lipid and protein oxidation and improved sensory scores. These results indicated that PE was effective on retarding lipid and protein oxidation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. The importance of mines for ultimate storage at Deilmann-Haniel Shaft Sinking

    International Nuclear Information System (INIS)

    Greinacher, Jochen; Oellers, Thomas; Ahlbrecht, Thomas

    2011-01-01

    Deilmann-Haniel Shaft Sinking GmbH and its predecessor and associate companies have been involved in projects for underground ultimate storage in Germany, Europe and America for over 45 years. The field of activities previously comprised surveying, planning and sinking of shafts, repair and conversion work, design of underground sealing structures, planning of conveyors and support of the BfS in planning approval procedures. Following discontinuation of activities in the German coal mining industry the use of mines for ultimate storage is an important support for German specialist mining companies. The use of mines for ultimate storage ensures that the existing mining know how in Germany is maintained, because training of the younger generation on the commercial and engineering side of the companies is made possible by the imminent major projects.

  5. Solar Refrigerators Store Life-Saving Vaccines

    Science.gov (United States)

    2014-01-01

    Former Johnson Space Center engineer David Bergeron used his experience on the Advanced Refrigeration Technology Team to found SunDanzer Refrigeration Inc., a company specializing in solar-powered refrigerators. The company has created a battery-free unit that provides safe storage for vaccines in rural and remote areas around the world.

  6. Quality of Milk Pasteurized Produced By UD. Gading Mas During Storage in Refrigerator

    Directory of Open Access Journals (Sweden)

    Manik Eirry Sawitri

    2012-02-01

    Full Text Available The aim of this research was to study pasteurized milk quality produced by UD. Gading Mas on pH, Acidity, alcohol test and TPC during 5 days storage in refrigerator. On first day showed that  weight mass 1,06 (w/w; fat content 2,00 (g/100g,  protein content 3,02  (g/100g, Zn 1,67 ppm, Cu<0,005 ppm, Pb 0,02 ppm,  As  0,0120 ppm, Hg< 0,0002 ppm, Sn 1,60 ppm dan Cd < 0,001 ppm and organoleptic test included color, flavor and taste were normal. Pasteurized milk characteristic during 5 days refrigeration for pH were 6,57;6,58;6,73;6,60 and 6,50 respectively. Acidity were 1,147 %, 0,145 %, 0,145%, 0,157 %, 0,156 % and 0,175  % respectively. TPC were 6,16 x 101, 1,2. 104; 3,15.104, 0,42.106 and 3,5.108 respectively. It concluded that pasteurized milk produced by UD Gading Mas fulfilled SNI quality standard based on weight mass, pH, acidity, fat, protein, heavy metal content, organoleptic test and TPC.   Keywords: pasteurized milk, quality, refrigerator

  7. Irradiation of ground beef with the purpose of refrigerated storage

    International Nuclear Information System (INIS)

    Keskin, S.

    1977-01-01

    Ground beef packaged in polyethylene film was irradiated at different dose levels ranging from 0.25 to 1.0 Mrad and stored at 3+-1 0 C. Bacteriological and organoleptic evaluations were carried out immediately after irradiation and at weekly intervals thereafter. The red color of the meat was darker after irradiation and this darkening increased with radiation dose. This color change was limited to the surface of the samples. The results of the bacteriological and organoleptic examination indicate that irradiation at 0.25 Mrad permits refrigerated storage of ground beef for 3 weeks, 0,5 Mrad for 6 weeks. Coliforms were found only in non-irradiated samples [fr

  8. Evaluating the effectiveness of supplementary means in refrigerator storage of fresh fruits

    International Nuclear Information System (INIS)

    Kalinov, V.

    1985-01-01

    Linear empirical correlations were obtained by applying a statistical model with probative-logarithmic transformation of the experimental data. On such base were predicted the probabal dates of fungal affection to a certain percent and the efficiency of supplementary means to refrigeration storage of fresh fruits (fungicides, ionizing radiation, etc.). Using data with the strawberry cv. Red Gautlet, the main criteria characterizing fruit keeping ability were assessed - dates of fruit decay appearance; of 5% decay, which was accepted for storage; percent of total quantitative losses; percent of fruits preserving their initial quality; mean daily rates of increasing total losses and decreasing the quality for accepted time of storage. The combined grading of these criteria found that fruits of the strawberry cv. Red Gauntlet were preserved best by gamma irradiation in a 2,5 kGy dose together with fruit packing in contractable folio and storage at 10 grad C. Under such conditions the fruits could be stored for 10 days with total quantitative losses (wastage and decay) of 6%, preserving 85% of the initial quality

  9. STORAGE AND RECOVERY OF SECONDARY WASTE COMING FROM MUNICIPAL WASTE INCINERATION PLANTS IN UNDERGROUND MINE

    Directory of Open Access Journals (Sweden)

    Waldemar Korzeniowski

    2016-09-01

    Full Text Available Regarding current and planned development of municipal waste incineration plants in Poland there is an important problem of the generated secondary waste management. The experience of West European countries in mining shows that waste can be stored successfully in the underground mines, but especially in salt mines. In Poland there is a possibility to set up the underground storage facility in the Salt Mine “Kłodawa”. The mine today is capable to locate over 3 million cubic meters and in the future it can increase significantly. Two techniques are proposed: 1 – storage of packaged waste, 2 – waste recovery as selfsolidifying paste with mining technology for rooms backfilling. Assuming the processing capacity of the storage facility as 100 000 Mg of waste per year, “Kłodawa” mine will be able to accept around 25 % of currently generated waste coming from the municipal waste incineration plants and the current volume of the storage space is sufficient for more than 20 years. Underground storage and waste recovery in mining techniques are beneficial for the economy and environment.

  10. Large Scale Production of Densified Hydrogen Using Integrated Refrigeration and Storage

    Science.gov (United States)

    Notardonato, William U.; Swanger, Adam Michael; Jumper, Kevin M.; Fesmire, James E.; Tomsik, Thomas M.; Johnson, Wesley L.

    2017-01-01

    Recent demonstration of advanced liquid hydrogen storage techniques using Integrated Refrigeration and Storage (IRAS) technology at NASA Kennedy Space Center led to the production of large quantities of solid densified liquid and slush hydrogen in a 125,000 L tank. Production of densified hydrogen was performed at three different liquid levels and LH2 temperatures were measured by twenty silicon diode temperature sensors. System energy balances and solid mass fractions are calculated. Experimental data reveal hydrogen temperatures dropped well below the triple point during testing (up to 1 K), and were continuing to trend downward prior to system shutdown. Sub-triple point temperatures were seen to evolve in a time dependent manner along the length of the horizontal, cylindrical vessel. Twenty silicon diode temperature sensors were recorded over approximately one month for testing at two different fill levels (33 67). The phenomenon, observed at both two fill levels, is described and presented detailed and explained herein., and The implications of using IRAS for energy storage, propellant densification, and future cryofuel systems are discussed.

  11. Biochemical Characteristics and Viability of Probiotic and Yogurt Bacteria in Yogurt during the Fermentation and Refrigerated Storage

    OpenAIRE

    F Sarvari; A.M. Mortazavian; M.R. Fazei

    2014-01-01

    This research aimed to investigate the viability of probiotic bacteria (Lactobacillus acidophilus LA-5 and Bifidobacterium lactis BB-12) and yogurt bacteria (Streptococcus thermophilus and Lactobacillus delbrueckii ssp. bulgaricus) in yogurt during the fermentation, immediately after fermentation and during refrigerated storage (21 d, 4˚C). Also the biochemical characteristics of milk as affected by the commercial 4-strain mixed starter culture were investigated. Storage time affected the via...

  12. Data-Driven Control of Refrigeration System

    DEFF Research Database (Denmark)

    Vinther, Kasper

    Refrigeration is used in a wide range of applications, e.g., for storage of food at low temperatures to prolong shelf life and in air conditioning for occupancy comfort. The main focus of this thesis is control of supermarket refrigeration systems. This market is very competitive and it is import......Refrigeration is used in a wide range of applications, e.g., for storage of food at low temperatures to prolong shelf life and in air conditioning for occupancy comfort. The main focus of this thesis is control of supermarket refrigeration systems. This market is very competitive...... traditionally are a pressure and a temperature sensor. In this thesis, a novel maximum slope-seeking (MSS) control method is developed. This has resulted in a control implementation, which successfully has been able to control the evaporator superheat in four widely different refrigeration system test...... problems. The method utilizes the qualitative nonlinearity in the system and harmonic analysis of a perturbation signal to reach an unknown, but suitable, operating point. Another important control task in refrigeration systems is to maintain the temperature of the refrigerated space or foodstuff within...

  13. Active packaged lamb with oxygen scavenger/carbon dioxide emitter sachet: physical-chemical and microbiological stability during refrigerated storage

    Directory of Open Access Journals (Sweden)

    Marco Antonio Trindade

    2013-09-01

    Full Text Available Lamb meat has been commercialized in Brazil almost exclusively as a frozen product due to the longer shelf life provided by freezing when compared to refrigeration. However, as a result of the current trend of increased demand for convenience products, a need has emerged for further studies to facilitate the marketing of refrigerated lamb cuts. The aim of the present study was to evaluate the contribution of active packaging technology in extending the shelf life of lamb loins (Longissimus lumborum stored under refrigeration (1±1 ° C when compared to the traditional vacuum packaging. For this purpose, two kinds of sachets were employed: oxygen scavenger sachet and oxygen scavenger/carbon dioxide emitter sachet. Experiments were conducted in three treatments: 1 Vacuum (Control, 2 Vacuum + oxygen scavenger sachet and 3 Vacuum + oxygen scavenger/carbon dioxide emitter sachet. Microbiological (counts of anaerobic psychrotrophs, coliform at 45 ° C, coagulase-positive staphylococci, Salmonella and lactic acid bacteria and physical-chemical (thiobarbituric acid reactive substances, objective color, pH value, water loss from cooking and shear force analyses were carried out weekly for a total storage period of 28 days. The experiment was performed three times for all treatments. Results showed that the lamb meat remained stable with respect to the majority of the evaluated physical and chemical indexes and remained within the standards established by Brazilian legislation for pathogenic microorganisms throughout the storage period in all three packaging systems. However, all treatments presented elevated counts of anaerobic psychrotrophic microorganisms and lactic acid bacteria, reaching values above 10(7 CFU/g at 28 days of storage. Thus, under the conditions tested, neither the oxygen scavenger sachet nor the dual function sachet (oxygen scavenger/carbon dioxide emitter were able to extend the shelf life of refrigerated lamb loin when added to this

  14. Fermilab tevatron five refrigerator system tests

    International Nuclear Information System (INIS)

    Rode, C.; Ferry, R.; Leiniger, M.; Makara, J.; Misek, J.; Mizicko, D.; Richied, D.; Theilacker, J.

    1982-01-01

    The Fermilab Tevatron refrigeration system is described with the layout illustrated. The compressor control loops, the refrigerator control loops, and magnet control loops (two per refrigerator) are described and each illustrated. The mobile purifier is described. A five refrigerator test is presented, using two compressor buildings, satellite refrigerator concept test and the test current to the writing. The configuration of the five refrigerator test is diagramed

  15. Re-evaluation of monitored retrievable storage concepts

    International Nuclear Information System (INIS)

    Fletcher, J.F.; Smith, R.I.

    1989-04-01

    In 1983, as a prelude to the monitored retrievable storage (MRS) facility conceptual design, the Pacific Northwest Laboratory (PNL) conducted an evaluation for the US Department of Energy (DOE) that examined alternative concepts for storing spent LWR fuel and high- level wastes from fuel reprocessing. The evaluation was made considering nine concepts for dry away-from-reactor storage. The nine concepts evaluated were: concrete storage cask, tunnel drywell, concrete cask-in-trench, open-cycle vault, metal casks (transportable and stationary), closed-cycle vault, field drywell, and tunnel-rack vault. The purpose and scope of the re-evaluation did not require a repetition of the expert-based examinations used earlier. Instead, it was based on more detailed technical review by a small group, focusing on changes that had occurred since the initial evaluation was made. Two additional storage concepts--the water pool and the horizontal modular storage vault (NUHOMS system)--were ranked along with the original nine. The original nine concepts and the added two conceptual designs were modified as appropriate for a scenario with storage capacity for 15,000 MTU of spent fuel. Costs, area requirements, and technical and historical data pertaining to MRS storage were updated for each concept

  16. Re-evaluation of monitored retrievable storage concepts

    Energy Technology Data Exchange (ETDEWEB)

    Fletcher, J.F.; Smith, R.I.

    1989-04-01

    In 1983, as a prelude to the monitored retrievable storage (MRS) facility conceptual design, the Pacific Northwest Laboratory (PNL) conducted an evaluation for the US Department of Energy (DOE) that examined alternative concepts for storing spent LWR fuel and high- level wastes from fuel reprocessing. The evaluation was made considering nine concepts for dry away-from-reactor storage. The nine concepts evaluated were: concrete storage cask, tunnel drywell, concrete cask-in-trench, open-cycle vault, metal casks (transportable and stationary), closed-cycle vault, field drywell, and tunnel-rack vault. The purpose and scope of the re-evaluation did not require a repetition of the expert-based examinations used earlier. Instead, it was based on more detailed technical review by a small group, focusing on changes that had occurred since the initial evaluation was made. Two additional storage concepts--the water pool and the horizontal modular storage vault (NUHOMS system)--were ranked along with the original nine. The original nine concepts and the added two conceptual designs were modified as appropriate for a scenario with storage capacity for 15,000 MTU of spent fuel. Costs, area requirements, and technical and historical data pertaining to MRS storage were updated for each concept.

  17. REDUCING REFRIGERANT EMISSIONS FROM SUPERMARKET SYSTEMS

    Science.gov (United States)

    Large refrigeration systems are found in several applications including supermarkets, cold storage warehouses, and industrial processes. The sizes of these systems are a contributing factor to their problems of high refrigerant leak rates because of the thousands of connections, ...

  18. Effect of refrigerated storage on the quality characteristics of microwave cooked chicken seekh kababs extended with different non-meat proteins.

    Science.gov (United States)

    Bhat, Zuhaib Fayaz; Pathak, Vikas; Fayaz, Hina

    2013-10-01

    Storage quality of chicken seekh kababs extended with different legumes at optimum level viz. 15% cowpea, 15% green gram and 10% black bean were assessed in terms of physico-chemical, proximate, microbiological and sensory properties under aerobic packaging conditions at refrigeration temperature (4 ± 1°C). The chicken seekh kababs were prepared from spent hens meat by low power microwave method and extended with optimum level of different legume (hydrated 1:1 w/w) pastes replacing lean meat in the formulation. The chicken seekh kababs formulated without any extender served as control and were compared with extended chicken seekh kababs. The kababs were aerobically packaged in low density polyethylene (LDPE) pouches and were analyzed at a regular interval of 0, 7, 14 and 21 days during refrigerated storage at 4 ± 1°C. The results indicated a significant (p  0.05) increase and almost all the sensory attributes showed a declining trend with advancement of storage. Total plate count and psychrophillic count also increased significantly (p < 0.05) whereas coliforms were not detected throughout the period of storage. The products were acceptable throughout the storage period.

  19. Quality loss assessment in fish-based ready-to-eat foods during refrigerated storage

    Energy Technology Data Exchange (ETDEWEB)

    Pourashouri, P.; Chapela, M. J.; Atanassova, M.; Cabado, A. G.; Vieites, J. M.; Aubourg, S. P.

    2013-05-01

    The present research addresses the quality loss in two different ready-to-eat (RTE) sea foods. With this aim, chemical and microbiological parameters were measured in tuna lasagne (TL) and hake roe foods which were refrigerated (4 degree centigrade) for up to 35 and 71 days, respectively. Both foods showed a significant lipid oxidation (peroxide and interaction compound formation) development with storage time, which was especially marked in the case of the TL product, which also underwent an important lipid hydrolysis development. Both RTE products showed a low microbial development, no matter how much time had elapsed since the expiration dates; thus, low total viable count scores and volatile amine formation were attained while the presence of pathogen microorganisms was not detected. In view of the current increasing consumer demand for high quality refrigerated foods, the assessment of lipid damage related to nutritional and sensory values is recommended when fish-based RTE products are encountered. (Author) 46 refs.

  20. Monitoring of the storage facility Asse II

    International Nuclear Information System (INIS)

    Regenauer, Urban; Wittwer, Christiane

    2012-01-01

    The storage facility Asse II is former salt mine near Wolfenbuettel in Niedersachsen. From 1967 to 1978 totally 125787 barrels with low-and medium-level radioactive wastes were disposed in the salt cavern. Since 1988 ingress of saturated brines from the adjoining rocks were observed in the mine. An extensive monitoring concept was installed for the surveillance of possible radionuclides released with the mine air into the surrounding. The report is aimed to n describe the actual situation in the salt mine Asse II with special emphasis to the monitoring concept. The discussion is based on the history of the storage facility that was primarily a research mine. Furthermore a regional accompanying process is described that was created in 2007.

  1. Spent nuclear fuel storage - Basic concept

    International Nuclear Information System (INIS)

    Krempel, Ascanio; Santos, Cicero D. Pacifici dos; Sato, Heitor Hitoshi; Magalhaes, Leonardo de

    2009-01-01

    According to the procedures adopted in others countries in the world, the spent nuclear fuel elements burned to produce electrical energy in the Brazilian Nuclear Power Plant of Angra do Reis, Central Nuclear Almirante Alvaro Alberto - CNAAA will be stored for a long time. Such procedure will allow the next generation to decide how they will handle those materials. In the future, the reprocessing of the nuclear fuel assemblies could be a good solution in order to have additional energy resource and also to decrease the volume of discarded materials. This decision will be done in the future according to the new studies and investigations that are being studied around the world. The present proposal to handle the nuclear spent fuel is to storage it for a long period of time, under institutional control. Therefore, the aim of this paper is to introduce a proposal of a basic concept of spent fuel storage, which involves the construction of a new storage building at site, in order to increase the present storage capacity of spent fuel assemblies in CNAAA installation; the concept of the spent fuel transportation casks that will transfer the spent fuel assemblies from the power plants to the Spent Fuel Complementary Storage Building and later on from this building to the Long Term Intermediate Storage of Spent Fuel; the concept of the spent fuel canister and finally the basic concept of the spent fuel long term storage. (author)

  2. Effects of garlic extract on color, lipid oxidation and oxidative breakdown products in raw ground beef during refrigerated storage

    Directory of Open Access Journals (Sweden)

    XINZHUANG ZHANG

    2016-03-01

    Full Text Available The study aims to investigate the effects of garlic extracts on color, lipid oxidation, and oxidative breakdown products in raw ground beef during refrigerated storage. The two treatments were:control group (C, with no addition and experiment group (D, 50 mg garlic extracts added to 100 g beef. Adding garlic extracts significant increased a* value (PA ≤ 0.05, and significant decreased TBARS and PV values (PA ≤ 0.05. The pH and –SH value of D group had a decreasing tendency (PA=0.0522 and an increasing tendency (PA=0.0636 respectively compared to C group. Garlic extracts protected phospholipids, fatty acids and polypeptides from oxidation. The results indicatethat garlic extracts have the antioxidant activity, helping maintain the meat color, inhibiting lipid oxidation and protein degradation of raw ground beef during refrigerated storage.

  3. Thermodynamic, Environmental and Economic Analyses of Solar Ejector Refrigeration System Application for Cold Storage

    OpenAIRE

    İbrahim ÜÇGÜL

    2009-01-01

    The refrigeration processes have been widely applied for especially in cold storages. In these plants, the systems working with compressed vapour cooling cycles have been used as a classical method. In general, electrical energy is used for compressing in these processes. Although, mainly the electricity itself has no pollution effect on the environment, the fossil fuels that are widely used to produce electricity in the most of the world, affect the nature terribly. In short, these refrigera...

  4. Long-term plutonium storage: Design concepts

    International Nuclear Information System (INIS)

    Wilkey, D.D.; Wood, W.T.; Guenther, C.D.

    1994-01-01

    An important part of the Department of Energy (DOE) Weapons Complex Reconfiguration (WCR) Program is the development of facilities for long-term storage of plutonium. The WCR design goals are to provide storage for metals, oxides, pits, and fuel-grade plutonium, including material being held as part of the Strategic Reserve and excess material. Major activities associated with plutonium storage are sorting the plutonium inventory, material handling and storage support, shipping and receiving, and surveillance of material in storage for both safety evaluations and safeguards and security. A variety of methods for plutonium storage have been used, both within the DOE weapons complex and by external organizations. This paper discusses the advantages and disadvantages of proposed storage concepts based upon functional criteria. The concepts discussed include floor wells, vertical and horizontal sleeves, warehouse storage on vertical racks, and modular storage units. Issues/factors considered in determining a preferred design include operational efficiency, maintenance and repair, environmental impact, radiation and criticality safety, safeguards and security, heat removal, waste minimization, international inspection requirements, and construction and operational costs

  5. Retention of storage quality and post-refrigeration shelf-life extension of plum (Prunus domestica L.) cv. Santa Rosa using combination of carboxymethyl cellulose (CMC) coating and gamma irradiation

    International Nuclear Information System (INIS)

    Hussain, Peerzada R.; Suradkar, Prashant P.; Wani, Ali M.; Dar, Mohd A.

    2015-01-01

    Carboxymethyl cellulose (CMC) coatings alone and in combination with gamma irradiation was tested for maintaining the storage quality and extending shelf-life of plum. Matured green plums were CMC coated at levels 0.5–1.0% w/v and gamma irradiated at 1.5 kGy. The treated fruit including control was stored under ambient (temperature 25±2 °C, RH 70%) and refrigerated (temperature 3±1 °C, RH 80%) conditions. In fruits treated with individual treatments of 1.0% w/v CMC; 1.5 kGy irradiation and combination of 1.0% w/v CMC and 1.5 kGy irradiation, no decay was recorded up to 11, 17 and 21 days of ambient storage. Irradiation alone at 1.5 kGy gave 8 days extension in shelf-life of plum compared to 5 days by 1.0% w/v CMC coating following 45 days of refrigeration. All combinatory treatments of CMC coating and irradiation proved beneficial in maintaining the storage quality as well as delaying the decaying of plum during post-refrigerated storage at 25±2 °C, RH 70% but, combination of CMC at 1.0% w/v and 1.5 kGy irradiation was found significantly (p≤0.05) superior to all other treatments in maintaining the storage quality and delaying the decaying of plum. CMC coating of plums at 1.0% w/v followed by irradiation at 1.5 kGy resulted in chlorophyll retention of 19.4% after 16 days compared to 10% in control after 8 days of ambient storage. Under refrigerated conditions, same treatment gave retention of 67.6% in chlorophyll compared to 10.6% in control after 35 days of storage. The above combinatory treatment resulted in extension of 11 days in shelf-life of plum during post-refrigerated storage at 25±2 °C, RH 70% following 45 days of refrigeration. Based on microbial analysis, irradiation alone at 1.5 kGy and in combination with 1.0% w/v CMC resulted in 2.0 and 1.8 log reduction in yeast and mold count of plum fruit after 20 and 35 days of ambient and refrigerated storage, thereby ensuring consumer safety. - Highlights: • Irradiation and CMC alone at 1.5 k

  6. Excavation response in respect of the repository concept for the Konrad mine as seen by the mining authority

    International Nuclear Information System (INIS)

    Roehl, W.

    1989-01-01

    In connection with the securing technical check-up of the repository concept for the Konrad mine the Mining Authority of Lower Saxony was asked for a comment on the mining concern of the Konrad plan by the Ministry for Environmental Protection of Lower Saxony. Referring to excavation response the valuation of rock-mechanical data, efficiency of the dams, underground convergences and mining subsidence are important to the realisation of the repository concept

  7. High pressure processing for dark-firm-dry beef: effect on physical properties and oxidative deterioration during refrigerated storage.

    Science.gov (United States)

    Utama, Dicky Tri; Lee, Seung Gyu; Baek, Ki Ho; Chung, Woon Si; Chung, In Ae; Jeon, Jung Tae; Lee, Sung Ki

    2017-03-01

    Study on the application of high pressure processing (HPP) for dark-firm-dry (DFD) beef was conducted to observe whether HPP has any impact on physical properties and to evaluate oxidative deterioration during refrigerated storage under vacuum. The longissimus lumborum muscles obtained from Friesian Holstein steers (33±0.5 months old) with 24-h postmortem pH higher than 6.0 were vacuum-packed and subjected to pressurization at 200, 400, and 600 MPa for 180 s at 15°C±2°C; the samples were then stored for 9 days at 4°C±1°C and compared with control (0.1 MPa). HPP increased meat pH by 0.1 to 0.2 units and the tenderness of cooked DFD beef significantly with no significant effects on meat texture profile. The stability of meat pH was well maintained during refrigerated storage under vacuum. No clear effects were found on the activity of catalase and superoxide dismutase, however, glutathione peroxidase activity was significantly reduced by high pressure. HPP and storage time resulted in aroma changes and the increasing amount of malondialdehyde and metmyoglobin relative composition. Although the increasing amount of malondialdehyde content, metmyoglobin formation and aroma changes in HPP-treated samples could not be avoided, HPP at 200 MPa increased L* and a* values with less discoloration and oxidative deterioration during storage.

  8. Refrigerated display cabinets; Butikskyla

    Energy Technology Data Exchange (ETDEWEB)

    Fahlen, Per

    2000-07-01

    This report summarizes experience from SP research and assignments regarding refrigerated transport and storage of food, mainly in the retail sector. It presents the fundamentals of heat and mass transfer in display cabinets with special focus on indirect systems and secondary refrigerants. Moreover, the report includes a brief account of basic food hygiene and the related regulations. The material has been compiled for educational purposes in the Masters program at Chalmers Technical University.

  9. New concept for ARS dry spent fuel storage

    International Nuclear Information System (INIS)

    Doroszlai, P.G.K.; Johanson, N.W.; Patak, H.N.

    1980-01-01

    The dry fully passive and modular away-from-reactor (AFR) storage concept has been presented before for a size of 1500 to 3000 MTHM. Here it is suggested that the same concept is applicable for a small AR storage facility of 200 MTHM. Detailed investigations and feasibility studies have shown this concept to be economically interesting. Dry storage in the proposed concept has some other inherent advantages: spent fuel is stored in a dry and inert atmosphere, where no corrosion nor determination of cladding is to be expected during extended storage periods; storage canister and the silo concrete are additional barriers against activity release and increase therefore the security for long term safety; there are only passive systems involved where the heat is dissipated by natural convection and there is no need for additional emergency systems or special redundancy; concept of AR storage should be relatively easily licensed, as all requirements or constructions are well known standards of engineering; this storage concept creates no secondary waste nor contamination making decomissioning simple after retransfer of spent fuel canisters; manpower requirements for operation and maintenance is very small; operating costs are estimated to be some 2 US $/kg U (1980); investment costs are calculated to be 96 US $/kg U (May 1980) for a total size of 200 MTHM stored

  10. When are solar refrigerators less costly than on-grid refrigerators: A simulation modeling study.

    Science.gov (United States)

    Haidari, Leila A; Brown, Shawn T; Wedlock, Patrick; Connor, Diana L; Spiker, Marie; Lee, Bruce Y

    2017-04-19

    Gavi recommends solar refrigerators for vaccine storage in areas with less than eight hours of electricity per day, and WHO guidelines are more conservative. The question remains: Can solar refrigerators provide value where electrical outages are less frequent? Using a HERMES-generated computational model of the Mozambique routine immunization supply chain, we simulated the use of solar versus electric mains-powered refrigerators (hereafter referred to as "electric refrigerators") at different locations in the supply chain under various circumstances. At their current price premium, the annual cost of each solar refrigerator is 132% more than each electric refrigerator at the district level and 241% more at health facilities. Solar refrigerators provided savings over electric refrigerators when one-day electrical outages occurred more than five times per year at either the district level or the health facilities, even when the electric refrigerator holdover time exceeded the duration of the outage. Two-day outages occurring more than three times per year at the district level or more than twice per year at the health facilities also caused solar refrigerators to be cost saving. Lowering the annual cost of a solar refrigerator to 75% more than an electric refrigerator allowed solar refrigerators to be cost saving at either level when one-day outages occurred more than once per year, or when two-day outages occurred more than once per year at the district level or even once per year at the health facilities. Our study supports WHO and Gavi guidelines. In fact, solar refrigerators may provide savings in total cost per dose administered over electrical refrigerators when electrical outages are less frequent. Our study identified the frequency and duration at which electrical outages need to occur for solar refrigerators to provide savings in total cost per dose administered over electric refrigerators at different solar refrigerator prices. Copyright © 2017. Published

  11. Mining Diagnostic Assessment Data for Concept Similarity

    Science.gov (United States)

    Madhyastha, Tara; Hunt, Earl

    2009-01-01

    This paper introduces a method for mining multiple-choice assessment data for similarity of the concepts represented by the multiple choice responses. The resulting similarity matrix can be used to visualize the distance between concepts in a lower-dimensional space. This gives an instructor a visualization of the relative difficulty of concepts…

  12. Quality of hurdle treated pork sausages during refrigerated (4 ± 1°C) storage.

    Science.gov (United States)

    Thomas, R; Anjaneyulu, A S R; Kondaiah, N

    2010-06-01

    Pork sausages developed using hurdle technology was evaluated during refrigerated storage (4 ± 1°C). Hurdles incorporated were low pH, low water activity, vacuum packaging and post package reheating. Dipping in potassium sorbate solution prior to vacuum packaging was also tried. Hurdle treatment significantly (p sausages during storage, as indicated by TBARS and tyrosine values. Incorporation of hurdles decreased the growth of different spoilage and pathogenic microorganisms. Combination of pH, water activity, vacuum packaging and reheating inhibited the growth of yeast and molds up to 12 days, while additional dipping of sausages in 1% potassium sorbate solution prior to packaging inhibited their growth even on 30(th) day of storage. Incorporation of hurdles resulted in initial reduction in all the sensory attributes, but they helped to maintain these attributes for significantly longer period compared to control. Hurdle treated sausages exhibited no spoilage signs even on day 30, while the control sausages were found acceptable only up to 18 days.

  13. When are solar refrigerators less costly than on-grid refrigerators: A simulation modeling study☆

    Science.gov (United States)

    Haidari, Leila A.; Brown, Shawn T.; Wedlock, Patrick; Connor, Diana L.; Spiker, Marie; Lee, Bruce Y.

    2017-01-01

    Background Gavi recommends solar refrigerators for vaccine storage in areas with less than eight hours of electricity per day, and WHO guidelines are more conservative. The question remains: Can solar refrigerators provide value where electrical outages are less frequent? Methods Using a HERMES-generated computational model of the Mozambique routine immunization supply chain, we simulated the use of solar versus electric mains-powered refrigerators (hereafter referred to as “electric refrigerators”) at different locations in the supply chain under various circumstances. Results At their current price premium, the annual cost of each solar refrigerator is 132% more than each electric refrigerator at the district level and 241% more at health facilities. Solar refrigerators provided savings over electric refrigerators when one-day electrical outages occurred more than five times per year at either the district level or the health facilities, even when the electric refrigerator holdover time exceeded the duration of the outage. Two-day outages occurring more than three times per year at the district level or more than twice per year at the health facilities also caused solar refrigerators to be cost saving. Lowering the annual cost of a solar refrigerator to 75% more than an electric refrigerator allowed solar refrigerators to be cost saving at either level when one-day outages occurred more than once per year, or when two-day outages occurred more than once per year at the district level or even once per year at the health facilities. Conclusion Our study supports WHO and Gavi guidelines. In fact, solar refrigerators may provide savings in total cost per dose administered over electrical refrigerators when electrical outages are less frequent. Our study identified the frequency and duration at which electrical outages need to occur for solar refrigerators to provide savings in total cost per dose administered over electric refrigerators at different solar

  14. 1-GWh diurnal load-leveling superconducting magnetic energy storage system reference design. Appendix D: superconductive magnetic energy storage cavern construction methods and costs

    International Nuclear Information System (INIS)

    1979-09-01

    The excavation and preparation of an underground cavern to contain a 1-GWh diurnal load-leveling Superconducting Magnetic Energy Storage (SMES) unit is examined. The cavern's principal function is to provide a rock structure for supporting the magnetic forces from the charged storage coil. Certain economic considerations indicate the refrigerator cold box for the helium system should also be underground. The study includes such a provision and considers, among other things, rock bolting, water seepage, concrete lining of the walls, steel bearing pads, a system to prevent freezing of the walls, a mining schedule, and costs

  15. Refrigeration and global warming

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    Some aspects of global warming in general, and the implications for refrigerants and refrigerator efficiency in particular, are briefly considered in a question and answer format. The concepts of Global Warming Potential (GWP) and Total Equivalent Warming Impact (TEWI) are explained. GWP is an index which allows a simple comparison to be make between the warming effects of different gases on a kg to kg basis relative to carbon. The GWP depends both on the lifetime of a substance in the atmosphere and its infra-red absorption capacity. The overall warming effect of operating a refrigeration system for its entire life is measured by its TEWI. Chloroflourocarbons (CFCs) which have been widely used as refrigerants are powerful greenhouse gases with high GWPs. Because of the bank of CFCs in refrigerating systems, their levels in the atmosphere are still increasing and it will be some time before refrigerant changes will be effective in reducing the warming effects of refrigerant releases. Hydrocarbons, hydroflourocarbons and ammonia all have a part to play as substitute refrigerants. Refrigerator efficiency is very important in terms of reducing CO 2 emissions. (UK)

  16. E2 = Energy concept x final storage [+ the law?

    International Nuclear Information System (INIS)

    Schneider, Horst

    2010-01-01

    The world is changing all the time, opinions and evaluations assume new shapes. It is the function of the law to ensure reliability and confidence by its very continuity. However, it is not only the revisions of the law which are subject to the zeitgeist; also the interpretations and applications of the law are not exempt from current trends of thought. The coalition agreement signed by the CDU/CSU and FDP parties on October 26, 2009 announced an energy concept encompassing life extension of nuclear power plants and a continued exploration of the Gorleben salt dome as a repository for high-level waste producting heat. The Deutsche Umwelthilfe (DUH) tries to prove in a legal opinion that an extension of nuclear power plant life was illegal and unconstitutional because the problem of the back end of the fuel cycle was not likely to be solved in a foreseeable time. Continuing exploration of the Gorleben salt dome is based on mining law. The agency responsible for filing an application under the German Atomic Energy Act is the Federal Office for Radiation Protection (BfS). In Germany, the final storage issue has always been an area of violent political debate. Given the strategic purpose of the DUH legal opinion as a tool furthering opt-out of the use of nuclear power, several points are presented and discussed in this article which were overlooked in that opinion. The equation, 'energy concept x final storage =..?', seems to be open today. The law can support results. Existing legal regulations especially about the nuclear power sector must be used as starting points for new ideas: The existence of legal norms is to ensure reliability and confidence. Consequently, changes in the law must be prepared very thoroughly and weighed comprehensively. In current thinking, after all, transparency is part of political action, especially so in defining and implementing goals in topics such as the energy concept and final storage. Yet, unnecessary delays would not be justified

  17. Post-mining deterioration of bauxite overburdens in Jamaica: storage methods or subsoil dilution?

    Science.gov (United States)

    Harris, Mark A.; Omoregie, Samson N.

    2008-03-01

    Rapid degradation of disturbed soil from a karst bauxite mine in Jamaica was recorded. Substantial macronutrient losses were incurred during a short (1 month) or a long (12 months) storage of the replaced topsoils during frequent wet/dry changes. The results suggested very high rates (>70% in the first year) of soil degradation from storage, alongside moderate rates (30%) within the same storage dump. However, higher levels of soil organic matter (SOM) were indicated just below the surface, compared with the surface horizons. It was unlikely that under a high leaching humid tropical rainfall regime, natural degradation processes could have re-emplaced such material firmly intact in the 15-30 cm zone. It was therefore concluded that these SOM anomalies were due to mechanical dilution of surface soil with subsoil material during overburden removal and emplacement rather than from long storage. Increasing the soil organic content during storage could be one corrective approach. However, it is far less costly to exercise greater care to apply more precise overburden removal and emplacement techniques initially, than it is to correct the results of topsoil contamination with subsoil. Although this study was limited to one mine, in the context of imminent large-scale mining expansion and current practices, further investigations are needed to accurately ascertain the proportion of similar subsoil contamination in other bauxite-mined sites.

  18. High pressure processing for dark-firm-dry beef: effect on physical properties and oxidative deterioration during refrigerated storage

    Directory of Open Access Journals (Sweden)

    Dicky Tri Utama

    2017-03-01

    Full Text Available Objective Study on the application of high pressure processing (HPP for dark-firm-dry (DFD beef was conducted to observe whether HPP has any impact on physical properties and to evaluate oxidative deterioration during refrigerated storage under vacuum. Methods The longissimus lumborum muscles obtained from Friesian Holstein steers (33±0.5 months old with 24-h postmortem pH higher than 6.0 were vacuum-packed and subjected to pressurization at 200, 400, and 600 MPa for 180 s at 15°C±2°C; the samples were then stored for 9 days at 4°C±1°C and compared with control (0.1 MPa. Results HPP increased meat pH by 0.1 to 0.2 units and the tenderness of cooked DFD beef significantly with no significant effects on meat texture profile. The stability of meat pH was well maintained during refrigerated storage under vacuum. No clear effects were found on the activity of catalase and superoxide dismutase, however, glutathione peroxidase activity was significantly reduced by high pressure. HPP and storage time resulted in aroma changes and the increasing amount of malondialdehyde and metmyoglobin relative composition. Conclusion Although the increasing amount of malondialdehyde content, metmyoglobin formation and aroma changes in HPP-treated samples could not be avoided, HPP at 200 MPa increased L* and a* values with less discoloration and oxidative deterioration during storage.

  19. Food Safety Practices Linked with Proper Refrigerator Temperatures in Retail Delis.

    Science.gov (United States)

    Brown, Laura G; Hoover, Edward Rickamer; Faw, Brenda V; Hedeen, Nicole K; Nicholas, David; Wong, Melissa R; Shepherd, Craig; Gallagher, Daniel L; Kause, Janell R

    2018-05-01

    Listeria monocytogenes (L. monocytogenes) causes the third highest number of foodborne illness deaths annually. L. monocytogenes contamination of sliced deli meats at the retail level is a significant contributing factor to L. monocytogenes illness. The Centers for Disease Control and Prevention's Environmental Health Specialists Network (EHS-Net) conducted a study to learn more about retail delis' practices concerning L. monocytogenes growth and cross-contamination prevention. This article presents data from this study on the frequency with which retail deli refrigerator temperatures exceed 41°F, the Food and Drug Administration (FDA)-recommended maximum temperature for ready-to-eat food requiring time and temperature control for safety (TCS) (such as retail deli meat). This provision was designed to control bacterial growth in TCS foods. This article also presents data on deli and staff characteristics related to the frequency with which retail delis refrigerator temperatures exceed 41°F. Data from observations of 445 refrigerators in 245 delis showed that in 17.1% of delis, at least one refrigerator was >41°F. We also found that refrigeration temperatures reported in this study were lower than those reported in a related 2007 study. Delis with more than one refrigerator, that lacked refrigerator temperature recording, and had a manager who had never been food safety certified had greater odds of having a refrigerator temperature >41°F. The data from this study suggest that retail temperature control is improving over time. They also identify a food safety gap: some delis have refrigerator temperatures that exceed 41°F. We also found that two food safety interventions were related to better refrigerated storage practices: kitchen manager certification and recording refrigerated storage temperatures. Regulatory food safety programs and the retail industry may wish to consider encouraging or requiring kitchen manager certification and recording refrigerated

  20. Ultimate refrigerating conditions, behavior turning and a thermodynamic analysis for absorption–compression hybrid refrigeration cycle

    International Nuclear Information System (INIS)

    Zheng Danxing; Meng Xuelin

    2012-01-01

    Highlights: ► Two novel fundamental concepts of the absorption refrigeration cycle were proposed. ► The interaction mechanism of compressor pressure increasing with other key-parameters was investigated. ► A set of optimal operating condition of hybrid refrigeration cycle was found. ► A simulation and investigation for R134a-DMF hybrid refrigeration cycle was performed. - Abstract: The absorption–compression hybrid refrigeration cycle has been considered as an effective approach to reduce the mechanical work consumption by using low-grade heat, such as solar energy. This work aims at studying the thermodynamic mechanism of the hybrid refrigeration cycle. Two fundamental concepts have been proposed, which are the ultimate refrigerating temperature (or the ultimate temperature lift) and the behavior turning. On the basis of that, the interaction mechanism of compressor pressure increasing with other key-parameters and the impact of compressor pressure increasing on the cycle performance have been investigated. The key-parameters include the concentration difference, the circulation ratio of working fluid, etc. The work points out that the hybrid refrigeration cycle performance varies with the change of compressor outlet pressure and depends on which one achieves dominance in the hybrid refrigeration cycle, the absorption sub-system or the compression sub-system. The behavior turning point during parameters changing corresponds to a maximum value of the heat powered coefficient of performance. In this case, the hybrid refrigeration cycle performance is optimal because the low-grade heat utilization is the most effective. In addition, to validate the theoretical analysis, a solar hybrid refrigeration cycle with R134a–DMF as working pair was simulated. The Peng–Robinson equation of state was adopted to calculate thermophysical properties when the reliability assessment of the prediction models on the available literature data of R134a–DMF system had been

  1. Control Methods for Energy Management of Refrigeration Systems

    DEFF Research Database (Denmark)

    Shafiei, Seyed Ehsan

    is decreased as the method does not need an explicit model of the system and, at the same time, the desired load following performance is attained. Recent research findings indicate that the refrigeration system commonly employed in food transportation can account for 40% of the total greenhouse gas emissions...... from the corresponding vehicle engines. Finally, the problem of optimization of a hybrid transport refrigeration system is addressed here. The hybrid refrigeration system is made by the integration of conventional refrigeration technology with thermal energy storage devices....

  2. High temperature, short time pasteurization temperatures inversely affect bacterial numbers during refrigerated storage of pasteurized fluid milk.

    Science.gov (United States)

    Ranieri, M L; Huck, J R; Sonnen, M; Barbano, D M; Boor, K J

    2009-10-01

    The grade A Pasteurized Milk Ordinance specifies minimum processing conditions of 72 degrees C for at least 15 s for high temperature, short time (HTST) pasteurized milk products. Currently, many US milk-processing plants exceed these minimum requirements for fluid milk products. To test the effect of pasteurization temperatures on bacterial numbers in HTST pasteurized milk, 2% fat raw milk was heated to 60 degrees C, homogenized, and treated for 25 s at 1 of 4 different temperatures (72.9, 77.2, 79.9, or 85.2 degrees C) and then held at 6 degrees C for 21 d. Aerobic plate counts were monitored in pasteurized milk samples at d 1, 7, 14, and 21 postprocessing. Bacterial numbers in milk processed at 72.9 degrees C were lower than in milk processed at 85.2 degrees C on each sampling day, indicating that HTST fluid milk-processing temperatures significantly affected bacterial numbers in fluid milk. To assess the microbial ecology of the different milk samples during refrigerated storage, a total of 490 psychrotolerant endospore-forming bacteria were identified using DNA sequence-based subtyping methods. Regardless of processing temperature, >85% of the isolates characterized at d 0, 1, and 7 postprocessing were of the genus Bacillus, whereas more than 92% of isolates characterized at d 14 and 21 postprocessing were of the genus Paenibacillus, indicating that the predominant genera present in HTST-processed milk shifted from Bacillus spp. to Paenibacillus spp. during refrigerated storage. In summary, 1) HTST processing temperatures affected bacterial numbers in refrigerated milk, with higher bacterial numbers in milk processed at higher temperatures; 2) no significant association was observed between genus isolated and pasteurization temperature, suggesting that the genera were not differentially affected by the different processing temperatures; and 3) although typically present at low numbers in raw milk, Paenibacillus spp. are capable of growing to numbers that can

  3. Geo-science aims of underground exploration of the Gorleben salt mine

    International Nuclear Information System (INIS)

    Langer, M.; Venzlaff, H.

    1987-01-01

    The measures taken are explained separately, according to the technical areas geology/petrography - geophysics - engineering geology/geotechnology - geo-chemistry. The results of the underground exploration are used directly to produce documents for the planning process, securing proof and the final storage planning (specific site mine dimensions, analysis of accidents, storage strategies). After completion of underground exploration, geoscience information on the suitability of the salt mine at Gorleben will be available in connection with a storage concept agreed between the geo-technologists and the mining engineers. (orig.) [de

  4. DATA MINING. CONCEPTS AND APPLICATIONS IN BANKING SECTOR

    Directory of Open Access Journals (Sweden)

    ADRIAN IONUT PASCU

    2018-02-01

    Full Text Available The concept of banking refers to the multitude of services and products that commercial banks offer to clients and include besides transactional accounts both passive and active products. Due to the increased competitiveness in banking, the relationship between the bank and the client has become an essential factor for the strategy in order to increase customer satisfaction. Currently the banking system is able to store impressive amounts of data that they collect daily, from customer data and transaction details to data on their transactional or risk profile. The process through which large amounts of data are analyzed, extracted, identified and the information obtained using mathematical and statistical models are interpreted is known as data mining. The discovery of knowledge from data involves identifying some models, some patterns with which certain events or possible risks are anticipated. This process helps banks to develop strategies in areas such as customer retention and loyalty, customer satisfaction, fraud detection and prevention, risk management, money laundering prevention. The aim of this paper is to present the concept of data mining and the concept of data discovery (KDD, but also the impact and important use of data mining techniques in the banking sector. This paper explores and reviews various data mining techniques that are applied in the banking sector but also provides insight into how these techniques are used in different areas to make decision-making easier and more efficient.

  5. Physicochemical Properties of Probiotic Soy milk Chocolate Mousse During Refrigerated Storage

    Directory of Open Access Journals (Sweden)

    Golnoush Taghizadeh

    2018-03-01

    Full Text Available Background and Objective: Recently, several researchers have shown the benefits deriving from probiotic products containing lactobacilli and bifidobacteria in their formulation. The purpose of this study was to develop a probiotic chocolate mousse using milk and soy milk in formulation with regard to survival of probiotic bacteria and sensorial acceptance during 21 days. Material and Methods: Nine functional probiotic chocolate mousse formulations were produced by milk, milk/soy milk and soy milk and 3 probiotic strains (Lactobacillus acidophilus; Lactobacillus paracasei; Bifidobacteriumlactis. ThepH, acidity, survival of microbial strains, rheological and sensory properties of all treatments were monitored during 21 days refrigerated storage (4°C. Results and Conclusion: The pH drop rate and acidity increase rate of all samples were significant during 21 days of storage (p≤0.05. There was a significant increase in the probiotic bacteria of all samples during 21 days of storage at 4°C (p≤0.05. However, the rate of probiotics growth was accelerated in formulation prepared with soy milk and milk/soy milk (1:1 in the chocolate mousse at day 7 and 14. Rheological experiment demonstrated that all samples known as viscoelastic solid dessert had shear-thinning behavior. In conclusion, chocolate dessert including soy milk as well as milk was shown to be more effective vehicle for delivery of probiotics, including Lactobacillus acidophilus, Lactobacillus paracasei, Bifidobacteriumlactis. Conflict of interest: The authors declare no conflict of interest.

  6. Effect of gamma irradiation and refrigeration storage on microbial, sensorial and chemical quality of fresh-cut lettuce

    International Nuclear Information System (INIS)

    Hammad, A. A.; Taha, S. M.; Amal, S. M.; Gebreel, H. M.

    2010-01-01

    Fresh-cut lettuce samples were collected and examined for their microbial, sensory and chemical qualities. All the examined samples had high level of microbial load. All examined samples contained Escherichia coli (E. coli), Enterococcus faecalis (Ent. faecalis), Staphylococcus aureus (S. aureus) and Aeromonas hydrophila (A. hydrophila), indicating that most these samples were unsatisfactory. Listeria monocytogenes (L monocytogenes) and Salmonella spp were not detected. Irradiation caused a great reduction in all microbial loads. During refrigerated storage, the counts of all microorganisms increased, but the rate of increase was slower in irradiated samples. Irradiation dose of 3 kGy was the optimum dose for preservation of fresh-cut lettuce which extended the refrigeration shelf-life up to 20 days and it was sufficient in eliminating all pathogenic bacteria without adverse effect on sensorial quality and slight effect on chemical quality.

  7. At-reactor storage concepts criteria for preliminary assessment

    International Nuclear Information System (INIS)

    Boydston, L.A.

    1981-12-01

    The licensing, safety, and environmental considerations of four wet and four dry at-reactor storage concepts are presented. Physical criteria for each concept are examined to determine the minimum site and facility requirements which must be met by a utility which desires to expand its at-reactor spent fuel storage capability

  8. A concept of an electricity storage system with 50 MWh storage capacity

    Directory of Open Access Journals (Sweden)

    Józef Paska

    2012-06-01

    Full Text Available Electricity storage devices can be divided into indirect storage technology devices (involving electricity conversion into another form of energy, and direct storage (in an electric or magnetic fi eld. Electricity storage technologies include: pumped-storage power plants, BES Battery Energy Storage, CAES Compressed Air Energy Storage, Supercapacitors, FES Flywheel Energy Storage, SMES Superconducting Magnetic Energy Storage, FC Fuel Cells reverse or operated in systems with electrolysers and hydrogen storage. These technologies have diff erent technical characteristics and economic parameters that determine their usability. This paper presents two concepts of an electricity storage tank with a storage capacity of at least 50 MWh, using the BES battery energy storage and CAES compressed air energy storage technologies.

  9. Concepts for a low-vibration and cryogen-free tabletop dilution refrigerator

    Science.gov (United States)

    Uhlig, Kurt

    2017-10-01

    The purpose of this article is to describe several concepts of how to cool a modern tabletop dilution refrigerator (DR) with a cryogen-free pulse tube cryocooler (PTC). Tabletop DRs have come more and more into the focus of scientists, recently, because they offer easy access to the mixing chamber mounting plate from all directions and because of their very short cooldown times. However, these milli-Kelvin coolers are precooled with LHe which makes their handling inconvenient and often expensive. In the paper it is explained how a cryocooler can be directly coupled to a DR unit making the use of LHe superfluous. Furthermore, concepts are discussed where a tabletop DR is cooled by a remote PTC; PTC and DR are mounted in separate vacuum containers which are connected by a stainless steel bellows tube. This kind of apparatus would offer an extremely low level of vibration at the mixing chamber mounting plate.

  10. Microstructural characteristics and gastro-small intestinal digestion in vitro of potato starch: Effects of refrigerated storage and reheating in microwave.

    Science.gov (United States)

    Colussi, Rosana; Singh, Jaspreet; Kaur, Lovedeep; Zavareze, Elessandra da Rosa; Dias, Alvaro Renato Guerra; Stewart, Robert B; Singh, Harjinder

    2017-07-01

    The objective of our study was to evaluate paste clarity, retrogradation (syneresis %), thermal characteristics and kinetics of glucose release during in vitro gastro-small intestinal digestion of freshly cooked and refrigerated potato starch. Freshly cooked starch pastes had a paste clarity of 71%, which decreased to 35.4% whereas syneresis (%) increased after 7days of refrigerated storage. The X-ray and thermal characteristics of native, retrograded and microwave reheated starch samples differed significantly from each other. For the freshly cooked starch pastes, ∼88% starch hydrolysis was observed at the end (150min) of digestion under simulated gastro-small intestinal conditions that decreased to ∼70% for the 7day stored pastes. The hydrolysis (%) of refrigerated pastes increased to 86% and 92% after one and two cycles of microwave reheating, respectively. These results contribute to the understanding of starch retrogradation in relation to starch digestion. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Studies on the quality of duck meat sausages during refrigeration.

    Science.gov (United States)

    Naveen, Z; Naik, B R; Subramanyam, B V; Reddy, P M

    2016-01-01

    Duck farming is on the raise in the current scenario, but processed products from duck meat are still uncommon to find. Investigating the duck meat qualities during storage will provide information to enhance duck meat utilization. Development of ready-to-eat and ready-to-cook duck meat products is expected to increase and improve non-chicken meat-based protein. The Study was aimed to evaluate the changes in quality characteristics of duck meat sausages preserved by refrigeration (7 ± 1 °C). Duck meat sausages were prepared by utilizing raw and partially cooked duck meat with addition of soy flour at 10% level as a binder. Different quality characteristics like physical and chemical characteristics, proximate composition, and organoleptic characteristics were evaluated. Cooking loss of partially cooked meat sausages was lower than raw duck meat sausages, whereas emulsion stability and 2-thiobarbituric acid (TBA) values of raw duck meat sausages were lesser than partially cooked meat sausages. Cooking loss and emulsion stability decreased in both types of meat sausages, while, 2-TBA values increased as refrigerated storage progressed for 14 days. Percent moisture content of raw duck meat sausages was higher than partially cooked meat sausages, which decreased in both types of meat sausages as refrigerated storage progressed for 14 days. Percent crude protein (CP) and percent ether extract (EE) content of partially cooked duck meat sausages were higher than raw duck meat sausages. Regardless of type of meat used, refrigerated storage of sausages increased CP and EE up to 10th day but decreased upon further storage up to 14th day. Organoleptic scores for raw duck meat sausages were higher than partially cooked duck meat sausages and all the scores decreased with an increase in the storage period. However the scores were within the acceptable limits. The findings prove that, duck meat can be effectively acclaimed as an alternative avenue to meet the escalating

  12. Trial storage of high-level waste in the Asse II salt mine

    International Nuclear Information System (INIS)

    1984-01-01

    This report covers a second phase of the work performed by GSF and KfK in the Asse II salt mine, with a view to disposal of radioactive waste in salt formations. New items of the research were geophysical investigations of the behaviour of heated salt and preparation of a trial storage in the Asse II salt mine

  13. Fate of Salmonella throughout Production and Refrigerated Storage of Tahini.

    Science.gov (United States)

    Zhang, Yangjunna; Keller, Susanne E; Grasso-Kelley, Elizabeth M

    2017-06-01

    Tahini, a low-moisture food that is made from sesame seeds, has been implicated in outbreaks of salmonellosis. In this study, the fate of Salmonella was determined through an entire process for the manufacture of tahini, including a 24-h seed soaking period before roasting, subsequent grinding, and storage at refrigeration temperature. Salmonella populations increased by more than 3 log CFU/g during a 24-h soaking period, reaching more than 7 log CFU/g. Survival of Salmonella during roasting at three temperatures, 95, 110, and 130°C, was assessed using seeds on which Salmonella was grown. Salmonella survival was impacted both by temperature and the water activity (a w ) at the beginning of the roasting period. When roasted at 130°C with a high initial a w (≥0.90) and starting Salmonella populations of ∼8.5 log CFU/g, populations quickly decreased below detection limits within the first 10 min. However, when the seeds were reduced to an a w of 0.45 before roasting at the same temperature, 3.5 log CFU/g remained on the seeds after 60 min. In subsequent storage studies, seeds were roasted at 130°C for 15 min before processing into tahini. For the storage studies, tahini was inoculated using two methods. The first method used seeds on which Salmonella was first grown before roasting. In the second method, Salmonella was inoculated into the tahini after manufacture. All tahini was stored for 119 days at 4°C. No change in Salmonella populations was recorded for tahini throughout the entire 119 days regardless of the inoculation method used. These combined results indicate the critical importance of a w during a roasting step during tahini manufacture. Salmonella that survive roasting will likely remain viable throughout the normal shelf life of tahini.

  14. Time-Temperature Profiling of United Kingdom Consumers' Domestic Refrigerators.

    Science.gov (United States)

    Evans, Ellen W; Redmond, Elizabeth C

    2016-12-01

    Increased consumer demand for convenience and ready-to-eat food, along with changes to consumer food purchase and storage practices, have resulted in an increased reliance on refrigeration to maximize food safety. Previous research suggests that many domestic refrigerators operate at temperatures exceeding recommendations; however, the results of several studies were determined by means of one temperature data point, which, given temperature fluctuation, may not be a true indicator of actual continual operating temperatures. Data detailing actual operating temperatures and the effects of consumer practices on temperatures are limited. This study has collated the time-temperature profiles of domestic refrigerators in consumer kitchens (n = 43) over 6.5 days with concurrent self-reported refrigerator usage. Overall, the findings established a significant difference (P < 0.05) between one-off temperature (the recording of one temperature data point) and mean operating temperature. No refrigerator operated at ≤5.0°C for the entire duration of the study. Mean temperatures exceeding 5.0°C were recorded in the majority (91%) of refrigerators. No significant associations or differences were determined for temperature profiles and demographics, including household size, or refrigerator characteristics (age, type, loading, and location). A positive correlation (P < 0.05) between room temperature and refrigerator temperature was determined. Reported door opening frequency correlated with temperature fluctuation (P < 0.05). Thermometer usage was determined to be infrequent. Cumulatively, research findings have established that the majority of domestic refrigerators in consumer homes operate at potentially unsafe temperatures and that this is influenced by consumer usage. The findings from this study may be utilized to inform the development of shelf-life testing based on realistic domestic storage conditions. Furthermore, the data can inform the development of future

  15. Experimental Investigation on an Absorption Refrigerator Driven by Solar Cells

    Directory of Open Access Journals (Sweden)

    Zi-Jie Chien

    2013-01-01

    Full Text Available This experiment is to study an absorption refrigerator driven by solar cells. Hand-held or carried in vehicle can be powered by solar energy in places without power. In the evenings or rainy days, it is powered by storage battery, and it can be directly powered by alternating current (AC power supply if available, and the storage battery can be charged full as a backup supply. The proposed system was tested by the alternation of solar irradiance 550 to 700 W/m2 as solar energy and 500ml ambient temperature water as cooling load. After 160 minutes, the proposal refrigerator can maintain the temperature at 5–8°C, and the coefficient of performance (COP of NH3-H2O absorption refrigeration system is about 0.25. Therefore, this system can be expected to be used in remote areas for refrigeration of food and beverages in outdoor activities in remote and desert areas or long-distance road transportation of food or low temperature refrigeration of vaccine to avoid the deterioration of the food or the vaccines.

  16. Use of glucose oxidase to improve refrigerated dough quality

    Science.gov (United States)

    Refrigerated dough encompasses a wide range of products including bread, rolls, pastries and pizza crust and is a very popular choice for consumers. Two of the largest problems that occur during refrigerated dough storage are dough syruping and loss of dough strength. The goal of this study was to e...

  17. Effects of Freeze-dried Mulberry on Antioxidant Activities and Fermented Characteristics of Yogurt during Refrigerated Storage

    OpenAIRE

    Sung, Jung-Min; Kim, Young-Boong; Kum, Jun-Seok; Choi, Yun-Sang; Seo, Dong-Ho; Choi, Hyun-Wook; Park, Jong-Dae

    2015-01-01

    This study investigated the effect of added freeze-dried mulberry fruit juice (FDMJ) (1, 3 and 5%) on the antioxidant activity and fermented characteristic of yogurt during refrigerated storage. A decrease in pH of yogurt and increase in acidity was observed during fermentation. The yogurts with FDMJ exhibited faster rate of pH reduction than control. Initial lactic acid bacteria count of yogurt was 6.49-6.94 Log CFU/g and increased above 9 Log CFU/g in control and 1% in FDMJ yogurt for 24 h....

  18. Oxidative stability of pork emulsion containing tomato products and pink guava pulp during refrigerated aerobic storage

    OpenAIRE

    Joseph, Serlene; Chatli, Manish K.; Biswas, Ashim K.; Sahoo, Jhari

    2012-01-01

    Lipid oxidation-induced quality problems can be minimized with the use of natural antioxidants. Antioxidant potential of tomato puree (10 %; T-1), tomato pulp (12.5 %; T-2), lyophilized tomato peel (6 %; T-3), and pink guava pulp (10 %; T-4) was evaluated in raw pork emulsion during refrigerated storage for 9 days under aerobic packaging. The lycopene and β-carotene content varied in pork emulsion as T-3 > T-1 > T-2 > T-4 and decreased (P 

  19. Conception and simulation of an improved solar refrigeration unit

    International Nuclear Information System (INIS)

    Chaouachi, B.; Gabsi, S.

    2006-01-01

    If the solar energy possesses the advantage to be c lean , free and new able, this last is probably, considered like an adapted potential solution, that answers in even time at a economic preoccupation and ecological problems. Among the main done currently research is the use of free source to make operate system of refrigeration. following a bibliographic study on the absorption cycles, the utilized couples absorbents-refrigerating fluids and the capture of the solar energy, an unit refrigeration using an improved solar absorption cycle of ammonia has been conceived and studied. The simulation results in permanent regime concerned the determination of the variation of the performance criteria mainly according to the operatives kept for this study. The obtained results showed, that the improved mono pressure absorption cycle of ammonia is suitable well for the cold production by means of the solar energy and that with a simple plate collector we can reach a power, of the order of 900 watts sufficient for domestic use.(Author)

  20. Preservation Effect of Two-Stage Cinnamon Bark (Cinnamomum Burmanii) Oleoresin Microcapsules On Vacuum-Packed Ground Beef During Refrigerated Storage

    Science.gov (United States)

    Irfiana, D.; Utami, R.; Khasanah, L. U.; Manuhara, G. J.

    2017-04-01

    The purpose of this study was to determine the effect of two stage cinnamon bark oleoresin microcapsules (0%, 0.5% and 1%) on the TPC (Total Plate Count), TBA (thiobarbituric acid), pH, and RGB color (Red, Green, and Blue) of vacuum-packed ground beef during refrigerated storage (at 0, 4, 8, 12, and 16 days). This study showed that the addition of two stage cinnamon bark oleoresin microcapsules affected the quality of vacuum-packed ground beef during 16 days of refrigerated storage. The results showed that the TPC value of the vacuum-packed ground beef sample with the addition 0.5% and 1% microcapsules was lower than the value of control sample. The TPC value of the control sample, sample with additional 0.5% and 1% microcapsules were 5.94; 5.46; and 5.16 log CFU/g respectively. The TBA value of vacuum-packed ground beef were 0.055; 0.041; and 0.044 mg malonaldehyde/kg, resepectively on the 16th day of storage. The addition of two-stage cinnamon bark oleoresin microcapsules could inhibit the growth of microbia and decrease the oxidation process of vacuum-packed ground beef. Moreover, the change of vacuum-packed ground beef pH and RGB color with the addition 0.5% and 1% microcapsules were less than those of the control sample. The addition of 1% microcapsules showed the best effect in preserving the vacuum-packed ground beef.

  1. Data mining concepts and techniques

    CERN Document Server

    Han, Jiawei

    2005-01-01

    Our ability to generate and collect data has been increasing rapidly. Not only are all of our business, scientific, and government transactions now computerized, but the widespread use of digital cameras, publication tools, and bar codes also generate data. On the collection side, scanned text and image platforms, satellite remote sensing systems, and the World Wide Web have flooded us with a tremendous amount of data. This explosive growth has generated an even more urgent need for new techniques and automated tools that can help us transform this data into useful information and knowledge.Like the first edition, voted the most popular data mining book by KD Nuggets readers, this book explores concepts and techniques for the discovery of patterns hidden in large data sets, focusing on issues relating to their feasibility, usefulness, effectiveness, and scalability. However, since the publication of the first edition, great progress has been made in the development of new data mining methods, systems, and app...

  2. Spent unreprocessed fuel (SURF) facility evaluation plan of the alternative storage concepts

    International Nuclear Information System (INIS)

    Berry, S.M.

    1978-01-01

    Concepts were evaluated for the storage of unreprocessed spent fuel in a retrievable surface storage facility. This document provides a systematic format for making a concept selection from the seven alternative concepts presented in RHO-LD-2. Results of the evaluation was that the Drywell concept was rated highest with the Water Basin Concept and the Sealed Storage Cask concept with multiple canisters of SURF coming in a close second and third

  3. On sustainable development of uranium mining industry in China based on the concept of ecological security

    International Nuclear Information System (INIS)

    Wu Shali; Tai Kaixuan

    2011-01-01

    Ecological security is an important issue for sustainable development of mining industry, on which the development of nuclear industry and nuclear power is based. But uranium mining and processing has larger effect on ecological environment which mainly include tailings, waste rock, waste water, and radiation effects. In this paper, the dialectical relationship between ecological security and sustainable relationship is analyzed, the ecological safety concept at home and abroad is compared and the role that ecological safety plays in the sustainable development of uranium mining based on analysis of restricting factors on uranium mining in China from the perspective of ecological security is also probed into. To achieve sustainable development of the uranium mining industry in China, an ecological security concept from four aspects must be established: 1) the concept of ecological security management; 2) the scientific concept of ecological security; 3) the concept of ecological security investment; and 4) the concept of ecological security responsibility. (authors)

  4. General review of solar-powered closed sorption refrigeration systems

    International Nuclear Information System (INIS)

    Sarbu, Ioan; Sebarchievici, Calin

    2015-01-01

    Highlights: • Provide review of development in solar sorption refrigeration technologies. • Theoretical basis and applications of absorption and adsorption cycles are discussed. • Thermodynamic properties of most common working pairs have been reviewed. • Development of hybrid or thermal energy storage adsorption systems was explored. • A comparison between solar-powered absorption and adsorption systems was performed. - Abstract: The negative environmental impacts of burning fossil fuels have forced the energy research community seriously to consider renewable sources, such as naturally available solar energy. Thermally powered refrigeration technologies are classified into two categories: thermo-mechanical technology and sorption technology (open systems or closed systems). This paper provides a detailed review of the solar closed sorption (absorption and adsorption) refrigeration systems, which utilise working pairs (fluids). After an introduction of the basic principles of these systems, the history of development and recent advances in solar sorption refrigeration technologies are reported. The adsorption cooling typically has a lower heat source temperature requirement than the absorption cooling. Based on the coefficient of performance (COP), the absorption systems are preferred over the adsorption systems, and the higher temperature issues can be easily handled with solar adsorption systems. The thermodynamic properties of most common working fluids, as well as the use of ternary mixtures in solar-powered absorption systems, have been reviewed in this study. The paper also refers to new approaches to increase the efficiency and sustainability of the basic adsorption cycles, such as the development of hybrid or thermal energy storage adsorption systems. This research shows that solar-powered closed sorption refrigeration technologies can be attractive alternatives not only to serve the needs for air-conditioning, refrigeration, ice making, thermal

  5. Refrigeration: Introducing energy saving opportunities for business

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-04-15

    In some industries, most notably food and drink and chemicals, refrigeration accounts for a significant proportion of overall site energy costs. For instance, in the industrial handling of meat, poultry and fish, it often accounts for 50% of total energy costs. In ice-cream production the proportion is 70%. In a number of commercial sectors, refrigeration also represents a significant proportion of overall energy costs. For example: Cold storage 90%; Food supermarkets 50%; Small shops with refrigerated cabinets 70% or over; Pubs and clubs 30%. Against these high costs, even a small reduction in refrigeration energy use can offer significant cost savings, resulting in increased profits. Energy saving need not be expensive. Energy savings of up to 20% can be realised in many refrigeration plant through actions that require little or no investment. In addition, improving the efficiency and reducing the load on a refrigeration plant can improve reliability and reduce the likelihood of a breakdown. Most organisations can save energy and money on refrigeration by: More efficient equipment; Good maintenance; Housekeeping and control. This publication provides an understanding of the operation of refrigeration systems, identifies where savings can be realised and will enable readers to present an informed case on energy savings to key decision makers within their organisation. (GB)

  6. Biochemical Characteristics and Viability of Probiotic and Yogurt Bacteria in Yogurt during the Fermentation and Refrigerated Storage

    Directory of Open Access Journals (Sweden)

    F Sarvari

    2014-09-01

    Full Text Available This research aimed to investigate the viability of probiotic bacteria (Lactobacillus acidophilus LA-5 and Bifidobacterium lactis BB-12 and yogurt bacteria (Streptococcus thermophilus and Lactobacillus delbrueckii ssp. bulgaricus in yogurt during the fermentation, immediately after fermentation and during refrigerated storage (21 d, 4˚C. Also the biochemical characteristics of milk as affected by the commercial 4-strain mixed starter culture were investigated. Storage time affected the viability of all bacterial species. The concentration of lactic acid during the fermentation increased in parallel with the titrable acidity, and the concentration of acetic acid was proportional to the viability of Bifidobacterium lactis. The acetaldehyde level was decreased in the yogurt from day 0 up to the end of the storage. Streptococcus thermophilus and Lactobacillus delbrueckii ssp. bulgaricus were multiplied considerably during the fermentation. Streptococcus thermophilus could maintain its viability to the highest level, but Lactobacillus delbrueckii ssp. bulgaricus lost its viability rapidly during the cold storage compared to Streptococcus thermophilus. The multiplication and viability of probiotic bacteria were also influenced by the associative strains and species of yogurt organisms. Bifidobacteria counts were satisfactory. The loss of viability for bifidobacteria was gradual and steady during the storage, and they showed good stability during the storage as compared to Lactobacillus acidophilus.

  7. Review of investigations in eco-friendly thermoacoustic refrigeration system

    Directory of Open Access Journals (Sweden)

    Raut Ashish S.

    2017-01-01

    Full Text Available To reduce greenhouse gas emissions, internationally research and development is intended to improve the performance of conventional refrigeration system also growth of new-fangled refrigeration technology of potentially much lesser ecological impact. This paper gives brief review of research and development in thermoacoustic refrigeration also the existing situation of thermoacoustic refrigeration system. Thermoacoustic refrigerator is a novel sort of energy conversion equipment which converts acoustic power into heat energy by thermoacoustic effect. Thermoacoustic refrigeration is an emergent refrigeration technology in which there are no moving elements or any environmentally injurious refrigerants during its working. The concept of thermoacoustic refrigeration system is explained, the growth of thermoacoustic refrigeration, various investigations into thermoacoustic refrigeration system, various optimization techniques to improve coefficient of performance, different stacks and resonator tube designs to improve heat transfer rate, various gases, and other parameters like sound generation have been reviewed.

  8. Influence of yogurt fermentation and refrigerated storage on the stability of protein toxin contaminants.

    Science.gov (United States)

    Jackson, Lauren S; Triplett, Odbert A; Tolleson, William H

    2015-06-01

    Dairy products sold in a ready-to-eat form present the risk that adulterants persisting through manufacturing, storage, and distribution would reach consumers. Pathogenic microbes, including shigatoxigenic strains of Escherichia coli and the toxins they produce, are common food safety hazards associated with dairy products. Ricin and abrin are plant-derived ribosome-inactivating protein toxins related to the shiga-like toxins produced by E. coli. Limited information exists on the effects of manufacturing processes on the stabilities of these heat-resistant ribosome-inactivating proteins in the presence of foods. The goal of this study was to determine how typical yogurt manufacturing and storage processes influence ribosome-inactivating protein toxins. Ricin and abrin were added to skim or whole milk and batch pasteurized. Complete inactivation of both toxins was observed after 30 minutes at 85 °C. If the toxins were added after pasteurization, the levels of ricin and abrin in yogurt and their cytotoxic activities did not change significantly during fermentation or refrigerated storage for 4 weeks. The activities of ricin and abrin were inhibited by skim milk, nonfat yogurt, whole milk, and whole milk yogurt. The results showed minimal effects of the toxins on yogurt pH and %titratable acidity but inhibitory effects of yogurt on toxin activity. Published by Elsevier Ltd.

  9. Modeling and calculation of open carbon dioxide refrigeration system

    International Nuclear Information System (INIS)

    Cai, Yufei; Zhu, Chunling; Jiang, Yanlong; Shi, Hong

    2015-01-01

    Highlights: • A model of open refrigeration system is developed. • The state of CO 2 has great effect on Refrigeration capacity loss by heat transfer. • Refrigeration capacity loss by remaining CO 2 has little relation to the state of CO 2 . • Calculation results are in agreement with the test results. - Abstract: Based on the analysis of the properties of carbon dioxide, an open carbon dioxide refrigeration system is proposed, which is responsible for the situation without external electricity unit. A model of open refrigeration system is developed, and the relationship between the storage environment of carbon dioxide and refrigeration capacity is conducted. Meanwhile, a test platform is developed to simulation the performance of the open carbon dioxide refrigeration system. By comparing the theoretical calculations and the experimental results, several conclusions are obtained as follows: refrigeration capacity loss by heat transfer in supercritical state is much more than that in two-phase region and the refrigeration capacity loss by remaining carbon dioxide has little relation to the state of carbon dioxide. The results will be helpful to the use of open carbon dioxide refrigeration

  10. Effects of modified atmosphere, associated with masterpack transport packaging, and refrigerated storage time on the quality characteristics of pork loin cuts

    Directory of Open Access Journals (Sweden)

    Alessandra F. Rosa

    2013-10-01

    Full Text Available The objective of this research was to study the effects of modified atmosphere, associated with masterpack transport packaging, and refrigerated storage time on the quality characteristics of pork loin cuts. Cuts of pork loin were packaged in trays, covered with poly(vinyl chloride film. The trays were placed in a masterpack (MP, containing three gas compositions:  A 75% O2 : 25% CO2, B 50% O2 : 50% CO2 or C 100% CO2, and stored at 2 °C. Samples were taken after 1, 8, 15, and 22 days of storage, and evaluated for numerous shelf life traits. The development of Psychrotrophic aerobic bacteria and Pseudomonas spp. was found from the 15th day of storage. There was a significant treatment effect for some of the considered parameters, such as pH (P < 0.05 and color [L* (P < 0.07, a* (P < 0.07 and b* (P < 0.01]. There was a significant interaction (P < 0.01 for the TBARS values. It can be concluded, from the microbiological point of view, that the use of modified atmospheres containing 25% to 100% CO2 promotes the conservation of meat for up to 15 days of storage under refrigeration. From the point of view of color, atmospheres containing 75% O2 : 25% CO2 and 50% O2 : 50% CO2 ensure the color of packaged pork meat when stored at 2 °C for up to 15 days. From the point of view of lipid oxidation, packages with 100% CO2 are recommended for storage periods of more than 15 days, whereas those with 75% O2 : 25% CO2 are recommended for storage periods of up to 8 days.

  11. Efficient Energy-Storage Concept

    Science.gov (United States)

    Brantley, L. W. J.; Rupp, C.

    1982-01-01

    Space-platform energy-storage and attitude-stabilization system utilizes variable moment of inertia of two masses attached to ends of retractable cable. System would be brought to its initial operating speed by gravity-gradient pumping. When fully developed, concept could be part of an orbiting solar-energy collection system. Energy would be temporarily stored in system then transmitted to Earth by microwaves or other method.

  12. The effects of washing with Tamarind (Tamarindus indica L. water solution on shelf life of silver carp (Hypophthalmichthys molitrix fillet during refrigerator storage

    Directory of Open Access Journals (Sweden)

    Eshagh Zakipour Rahimabadi

    2016-01-01

    Full Text Available This study evaluated the antibacterial and antioxidant effects of tamarind water solution on shelf life of silver carp (Hypophthalmicthys molitrix fillet during refrigerator storage. Treatments of this study were unwashed samples (control, and samples washed with 1% and 2% tamarind water solution. Microbial, physicochemical and sensory analysis including total viable count (TVC, peroxide value (PV, thiobarbituric acid (TBA, total volatile base (TVB-N and pH were measured during 15 day storage at refrigerator (with 3 days intervals. Proximate analysis of samples also measured at day 0. TVC content was 0.93, 0.50 and 0.10 log CFU/g for control and treatments 1% and 2%, respectively and reached to 6.24, 5.82 and 5.21 log CFU/g at the end of storage period. At the end of storage period, the PV, TBA and TVB-N content were 8.4, 4.3, and 3.0 meq O2/Kg for control, 2.75, 1.35, and 0.50 mg/100g for 1% treatment, and 33.17, 23.90, and 22.10 mg N/100g for 2% treatment, respectively. This results showed the positive effect of tamarind to inhibit and delay fish fillet spoilage. According to sensory evaluation, the density of 1% tamarind was selected as the best density.

  13. Quality of low-fat pork sausages with tomato powder as colour and functional additive during refrigerated storage.

    Science.gov (United States)

    Kim, Il-Suk; Jin, Sang-Keun; Mandal, Prabhat Kumar; Kang, Suk-Nam

    2011-10-01

    Low fat pork sausages were formulated with tomato powder at 0% (C), 0.8% (T1), 1.2% (T2) and 1.5% (T3) levels in basic formula. With the increase in tomato powder concentration the lightness of the sausage decreased but the redness and yellowness increased significantly (p sausages with tomato powder were significantly (p sausage with tomato powder up to 1.5% was found to be well acceptable up to 30 days at refrigerated storage. This new product will have special value due to the functional additive lycopene in tomato powder.

  14. A Weibull model to describe antimicrobial kinetics of oregano and lemongrass essential oils against Salmonella Enteritidis in ground beef during refrigerated storage.

    Science.gov (United States)

    de Oliveira, Thales Leandro Coutinho; Soares, Rodrigo de Araújo; Piccoli, Roberta Hilsdorf

    2013-03-01

    The antimicrobial effect of oregano (Origanum vulgare L.) and lemongrass (Cymbopogon citratus (DC.) Stapf.) essential oils (EOs) against Salmonella enterica serotype Enteritidis in in vitro experiments, and inoculated in ground bovine meat during refrigerated storage (4±2 °C) for 6 days was evaluated. The Weibull model was tested to fit survival/inactivation bacterial curves (estimating of p and δ parameters). The minimum inhibitory concentration (MIC) value for both EOs on S. Enteritidis was 3.90 μl/ml. The EO concentrations applied in the ground beef were 3.90, 7.80 and 15.60 μl/g, based on MIC levels and possible activity reduction by food constituents. Both evaluated EOs in all tested levels, showed antimicrobial effects, with microbial populations reducing (p≤0.05) along time storage. Evaluating fit-quality parameters (RSS and RSE) Weibull models are able to describe the inactivation curves of EOs against S. Enteritidis. The application of EOs in processed meats can be used to control pathogens during refrigerated shelf-life. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Study of the effects of gamma radiation on the microbiological quality, lipid oxidation and sensory properties of mechanically deboned chicken meat throughout refrigerated and frozen storage

    International Nuclear Information System (INIS)

    Gomes, Heliana de Azevedo

    2002-01-01

    Mechanically deboned chicken meat (MDCM) is widely used in traditional meat products such as sausages. The proceed of mechanical separation results in grinding of the bones, liberating the marrow and rupturing cells, thus making the MDCM a favorable medium for biochemical reactions and microbiological growth. Irradiation using a Co 60 source is one of the processes which has been developed aimed at reducing contamination by spoilage and pathogenic microorganisms in foods. The main advantages of food irradiation are the possibilities of treating the already packaged products at refrigerated and frozen temperatures, ideal for a highly perishable product such as MDCM, which, being a ground, easily spoiled product, requires rapid cooling followed by freezing, immediately after processing. Processing with ionizing radiation results in chemical alterations in the food, including the production of volatile compounds and free radicals. Irradiation of meat in the frozen state reduces or eliminates the negative sensory effects of this process. In this context, this study aimed at evaluating the effects of gamma radiation at doses of 3.0 and 4.0 kGy, on the microbiological quality, lipid oxidation and sensory properties of MDCM, at the refrigerated (2 ± 1 deg C) and frozen (-18 ± 1 deg C) storage, The results showed that irradiation increased the shelf life of this raw material when stored under refrigeration, as compared to non-irradiated samples. Since doses of 3.0 kGy produced increases in the shelf life of refrigerated MDCM equal or greater than those produced by doses of 4.0 kGy, this dose was considered the most adequate for the irradiation of this raw material. According to the results of microbiological, chemical and sensorial testing in irradiated MDCM samples with doses of 3.0 kGy and 4.0 kGy, the material studied presented conditions that were adequate for human consumption during the 90 days of frozen storage, whereas samples of non-irradiated MDCM were shown to

  16. Recent investigations on refrigerants for magnetic refrigerators

    International Nuclear Information System (INIS)

    Hashimoto, T.

    1986-01-01

    In development of the magnetic refrigerator, an important problem is selection of magnetic materials as refrigerants. The main purpose of the present paper is to discuss the magnetic and thermal properties necessary for these refrigerants and to report recent investigations. Magnetic refrigerants can be expediently divided into two groups, one for the Carnottype magnetic refrigerator below 20 K and the other for the Ericsson-type refrigerator. The required physical properties of refrigerants in each type of the magnetic refrigerator are first discussed. And then, the results of recent investigations on the magnetic, thermal and magnetocaloric characters of several promising magnetic refrigerants are shown. Finally, a brief prospect of the magnetic refrigerants and refrigerators is given

  17. The HAW project. Test storage of high-level radiation sources in the Asse salt mine. Documentation and assessment of the storage system

    International Nuclear Information System (INIS)

    Mueller, K.; Rothfuchs, T.

    1994-01-01

    The HAW project aimed primarily at studying the interaction between high-level radioactive waste moulds and rock salt as the respository medium. Another priority was the prototype development and testing of a technical system for the emplacement of high-level radioactive moulds in deep storage boreholes. To simulate real high-level radioactive wastes, special high-level radiation sources (Cs-137, Sr-90) were produced in the United States of America under a German-American cooperation contract, for carrying out the tests at the Asse salt mine. The components of the storage system are described, their position and task within the entire handling procedure explained. Questions of radiation protection and accident protection, of functioning and operating reliability, of quality assurance and examination of documents, materials, of manufacture and functioning, and of documentation are dealt with in detail. With a view to the planning of storage techniques for a mine respository, the experience of development and operation is recorded, and recommendation of further developments are given. Problems which arose during work on the HAW project were partly due to test-specific reasons and will not or not in this form occur in a mine respository. It was planned to start the test emplacement in 1987, and it could have been executed in 1993 after appropriate preparation and approval of the storage system by the mining authority and the Hanover TUEV in 1991. In December 1992, however, the Federal Government decided to give up to the project due to the uncertain licensing situation, and to immediately stop all preparatory work. (orig./HP) [de

  18. Sheet GT3-2. General approach of life phases on a long term for uranium mining residues storages and comparison with other storages

    International Nuclear Information System (INIS)

    2009-01-01

    This document aims at specifying the short term, middle term and long term boundaries for a sustainable management and rehabilitated ancient uranium mining sites and of uranium mining residue storage sites. It presents a general overview of site evolution in time, and then, more precisely, the different functions (rehabilitation management, corrective actions, control and monitoring, and so on) and equipment (confinement works, measurement system) at stake in the management of these sites and the control of their impacts. Functions and equipment implemented on such a site, as well as time scales corresponding to different approaches are compared with those of other types of storage. The peculiarity of ancient uranium mining sites and its implications in terms of management on a long term are discussed

  19. Procurement and commissioning of the CHL refrigerator at CEBAF

    International Nuclear Information System (INIS)

    Chronis, W.C.; Arenius, D.M.; Bevins, B.S.; Ganni, V.; Kashy, D.H.; Keesee, M.M.; Reid, T.R.; Wilson, J.D.

    1996-01-01

    The CEBAF Central Helium Liquefier (CHL) provides 2K refrigeration to the 338 superconducting niobium cavities in two 400 MeV linacs and one 45 MeV injector. The CHL consists of three first stage and three second stage compressors, a 4.5K cold box, a 2K cold box, liquid and gaseous helium storage, liquid nitrogen storage, and transfer lines. Figure 1 presents a block diagram of the CHL refrigerator. The system was designed to provide 4.8 kW of primary refrigeration at 2K, 12 kW of shield refrigeration at 45K for the linac cryomodules, and 10 g/s of liquid flow for the end stations. In April 1994, stable 2K operation of the previously uncommissioned cold compressors was achieved. The cold compressors are a cold vacuum pump with an inlet temperature of circa 3.0K. These compressors operate on magnetic bearing,s and therefore eliminate the possibility of contamination due to any air leaks into the system. Operational data and commissioning experience as they relate to the warm gaseous helium compressors, turbines, instrumentation and control, and the cold compressors are presented

  20. Gas hydrate cool storage system

    Science.gov (United States)

    Ternes, M.P.; Kedl, R.J.

    1984-09-12

    The invention presented relates to the development of a process utilizing a gas hydrate as a cool storage medium for alleviating electric load demands during peak usage periods. Several objectives of the invention are mentioned concerning the formation of the gas hydrate as storage material in a thermal energy storage system within a heat pump cycle system. The gas hydrate was formed using a refrigerant in water and an example with R-12 refrigerant is included. (BCS)

  1. Viability of Lactobacillus acidophilus and Lactobacillus casei in fermented milk products during refrigerated storage.

    Science.gov (United States)

    Nighswonger, B D; Brashears, M M; Gilliland, S E

    1996-02-01

    The viability was investigated of five strains of Lactobacillus acidophilus and one strain of Lactobacillus casei that were added as adjuncts to yogurt and cultured buttermilk during 28 d of refrigerated storage at 5 to 7 degrees C. A modification of LBS (Lactobacillus selection) agar was used for the enumeration of L. acidophilus and L. casei. The medium allowed the colony formation of the adjunct bacteria while preventing colony formation of the traditional yogurt or buttermilk starter cultures. At each sampling period, colonies from the selective agar medium were isolated for confirmation of identity to confirm that only L. acidophilus and L. casei were enumerated, that their characteristics did not change during storage, or both. The strains of L. acidophilus varied in both cultured products. In buttermilk, L. acidophilus MUH-41, O-16, and L-1 exhibited no significant loss in viability, but strains 43121 and La-5 did. No significant loss in viability of L. acidophilus MUH-41 and L-1 occurred in yogurt prepared using culture CM2; however, strains 43121, O-16, and La-5 lost viability. In the yogurt prepared using culture YC-4, L. acidophilus 43121 exhibited no significant loss in viability, but MUH-41, O-16, L-1, and La-5 did. There was no loss in viability of L. casei GG during storage of any of the cultured products.

  2. Canadian experience with wet and dry fuel storage concepts

    International Nuclear Information System (INIS)

    Mayman, S.A.

    1978-07-01

    Canada has been storing fuel in water-filled pools for 30 years. There have been no significant problems, but until recently little effort has been invested in quantitative assessment of fuel performance under storage conditions. Work is now in progress to provide such information. Storage pools at nuclear generating stations have operated satisfactorily. The Canadian nuclear industry has nevertheless been studying methods for reducing storage costs and/or increasing reliability. Various concepts, using both water and air cooling, have been suggested. One such concept - the air-cooled concrete canister - is presently under test at the Whiteshell Nuclear Research Establishment. (author)

  3. High pressure processing for dark-firm-dry beef: effect on physical properties and oxidative deterioration during refrigerated storage

    OpenAIRE

    Dicky Tri Utama; Seung Gyu Lee; Ki Ho Baek; Woon Si Chung; In Ae Chung; Jung Tae Jeon; Sung Ki Lee

    2017-01-01

    Objective Study on the application of high pressure processing (HPP) for dark-firm-dry (DFD) beef was conducted to observe whether HPP has any impact on physical properties and to evaluate oxidative deterioration during refrigerated storage under vacuum. Methods The longissimus lumborum muscles obtained from Friesian Holstein steers (33?0.5 months old) with 24-h postmortem pH higher than 6.0 were vacuum-packed and subjected to pressurization at 200, 400, and 600 MPa for 180 s at 15?C?2?C; the...

  4. Magnetocaloric refrigeration concepts: current state of the art

    DEFF Research Database (Denmark)

    Nielsen, Kaspar Kirstein

    2014-01-01

    Refrigeration devices based on the magnetocaloric effect have been prototyped in great numbers during the past decade. The search for the optimal combination of magnetic field source, regenerator geometry, magnetocaloric material composition and flow system design has resulted in a variety...

  5. Addition of glucose oxidase for the improvement of refrigerated dough quality

    Science.gov (United States)

    Refrigerated dough encompasses a wide range of products and is a very popular choice for consumers. Two of the largest problems that occur during refrigerated dough storage are dough syruping and loss of dough strength. The goal of this study was to evaluate glucose oxidase as an additive to refri...

  6. Analysis of cooldown performance for Isabelle helium refrigerator

    International Nuclear Information System (INIS)

    Wu, K.C.; Brown, D.P.; Moore, R.W.

    1982-01-01

    The cooldown performance for the ISABELLE Helium refrigerator is analyzed in terms of the relationship between refrigerator and its load. The flow diagram for ISABELLE with its redundant turbines and heat exchangers is given. Cycle description and procedure for cooldown is described with the relationship between a refrigerator and its load illustrated. Pressure vs. temperature for ISABELLE load and the efficiency for a turbine are illustrated. The procedure for modeling the refrigerator and the concepts of maximizing the cooldown capacity are described. The results and discussion are accompanied with T-S diagrams for initial stage of cooldown and refrigerator characteristic at various return temperatures. The ISABELLE refrigerator with its reduncant expanders properly used achieves cooldown capacity well beyond its steady-state capacity. The cooldown rate at this stage relies on the design safety margin, which for the ISABELLE is 50%

  7. Modeling of Energy-saving System of Conditioning Mine Air for Shallow Underground Mines

    Science.gov (United States)

    Nikolaev, Alexandr; Miftakhov, Timur; Nikolaeva, Evgeniya

    2017-11-01

    Mines of Verkhnekamsk potassium-magnesium salt deposit in Perm Krai can be subsumed under shallow mines (depth less than 500 meters). At the present moment in shallow underground mines the are problem of condensate formation in large quantities, when ventilation warm seasons of the year. This problem is more actual for salt mine, where during contact between water and potassium-magnesium ore produced electrolyte, which give rise wear of equipment. For prevent/quantity reduction condensate formation in mine used system of conditioning (refrigerating and dehumidifying) mine air (ACS). However, application this system is limited by reason of tremendous costs of electric energy for their work.

  8. Effect of sage (Salvia officinalis) on the oxidative stability of Chinese-style sausage during refrigerated storage.

    Science.gov (United States)

    Zhang, L; Lin, Y H; Leng, X J; Huang, M; Zhou, G H

    2013-10-01

    The objective of this study was to assess the effect of sage, at levels of 0.05%, 0.1% and 0.15% (w/w), on the oxidative stability of Chinese-style sausage stored at 4°C for 21 days. The results showed that inclusion of sage in sausages resulted in lower L* values (Psage showed significantly retarded increases in TBARS values, and in the formation of protein carbonyls (Psage to the sausages at levels of 0.1% and 0.15% reduced textural deterioration during refrigerated storage (PSage used in this study had no negative effects on the sensory properties of sausages. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Effects of microwave cooking and refrigerated storage of main broiler parts on lipid oxidation in chicken muscle and skin

    International Nuclear Information System (INIS)

    Pikul, J.; Kummerow, F.A.

    1990-01-01

    From a total of 78 chickens, 24 carcasses were used to estimate the percentage for the individual cuts and their composition. Fifty-four carcasses were cut vertically into halves of which two-thirds were quartered, yielding front and hind quarters (Cuts 2 and 3). Half of these quarters were cut into individual pieces, yielding breasts and thighs with back ribs, drumsticks, and wings. The muscles and skin of one-third from each of the seven different cuts described above were analyzed raw for lipid oxidation products; while the remaining two-thirds were microwaved. Half of the microwaved cuts were analyzed 2 hours after cooking; the other half, after 4 days of storage at 4 C. The results indicated that the absolute amount of lipid oxidation products in chicken muscles and skin after microwave cooking and refrigerated storage was affected by the initial level of those products in the raw samples and by the particular cut of meat Cooking the different cuts of chicken carcasses by microwave significantly increased the amount of malonaldehyde (MA) and lipid-oxidation fluorescent products (LOFP) in the aqueous phase of Folch-extracted muscles and skin and in the organic phase of Folch-extracted skin lipids. Microwave cooking for the separate broiler parts (especially the drumsticks and wings, as compared to halves or quarters) produced the lowest amount of lipid oxidation products due to the shorter cooking time. Refrigerated storage of broiler parts cooked by microwave produced substantial amounts of MA and LOFP in the aqueous phase of the Folch extracted skin and in the organic phase of the Folch-extracted lipids from the muscles. (author)

  10. Alternative concepts for spent fuel storage basin expansion at Morris Operation

    International Nuclear Information System (INIS)

    Graf, W.A. Jr.; King, C.E.; Miller, G.P.; Shadel, F.H.; Sloat, R.J.

    1980-08-01

    Alternative concepts for increasing basin capabilities for storage of spent fuel at the Morris Operation have been defined in a series of simplified flow diagrams and equipment schematics. Preliminary concepts have been outlined for (1) construction alternatives for an add-on basin, (2) high-density baskets for storage of fuel bundles or possible consolidated fuel rods in the existing or add-on basins, (3) modifications to the existing facility for increasing cask handling and fuel receiving capabilities and (4) accumulation, treatment and disposal of radwastes from storage operations. Preliminary capital and operating costs have been prepared and resource and schedule requirements for implementing the concepts have been estimated. The basin expansion alternatives would readily complement potential dry storage projects at the site in an integrated multi-stage program that could provide a total storage capacity of up to 7000 tonnes of spent fuel

  11. Characterization of the indigenous microflora in raw and pasteurized buffalo milk during storage at refrigeration temperature by high-throughput sequencing.

    Science.gov (United States)

    Li, Ling; Renye, John A; Feng, Ling; Zeng, Qingkun; Tang, Yan; Huang, Li; Ren, Daxi; Yang, Pan

    2016-09-01

    The effect of refrigeration on bacterial communities within raw and pasteurized buffalo milk was studied using high-throughput sequencing. High-quality samples of raw buffalo milk were obtained from 3 dairy farms in the Guangxi province in southern China. Five liters of each milk sample were pasteurized (72°C; 15 s); and both raw and pasteurized milks were stored at refrigeration temperature (1-4°C) for various times with their microbial communities characterized using the Illumina Miseq platform (Novogene, Beijing, China). Results showed that both raw and pasteurized milks contained a diverse microbial population and that the populations changed over time during storage. In raw buffalo milk, Lactococcus and Streptococcus dominated the population within the first 24h; however, when stored for up to 72h the dominant bacteria were members of the Pseudomonas and Acinetobacter genera, totaling more than 60% of the community. In pasteurized buffalo milk, the microbial population shifted from a Lactococcus-dominated community (7d), to one containing more than 84% Paenibacillus by 21d of storage. To increase the shelf-life of buffalo milk and its products, raw milk needs to be refrigerated immediately after milking and throughout transport, and should be monitored for the presence of Paenibacillus. Results from this study suggest pasteurization should be performed within 24h of raw milk collection, when the number of psychrotrophic bacteria are low; however, as Paenibacillus spores are resistant to pasteurization, additional antimicrobial treatments may be required to extend shelf-life. The findings from this study are expected to aid in improving the quality and safety of raw and pasteurized buffalo milk. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  12. Effect of low-pressure plasma treatment on the color and oxidative stability of raw pork during refrigerated storage.

    Science.gov (United States)

    Ulbin-Figlewicz, Natalia; Jarmoluk, Andrzej

    2016-06-01

    The effect of low-pressure plasma on quality attributes of meat is an important aspect, which must be considered before application in food. The aim of this study was to determine the color, fatty acid composition, lipid oxidation expressed as thiobarbituric acid reactive substances and total antioxidant capacity of raw pork samples exposed to helium low-pressure plasma treatment (20 kPa) for 0, 2, 5, and 10 min during the storage period. The thiobarbituric acid reactive substance concentrations of all plasma-treated samples during storage were in the range from 0.26 to 0.61 mg malondialdehyde/kg. Exposure time caused significant changes only in total color difference, hue angle, and chroma after 10 min of treatment. Ferric reducing ability of plasma values of meat samples decreased from 1.93 to 1.40 mmol Trolox Eq/kg after 14 days of storage. The storage period significantly affected proportion of polyunsaturated fatty acids, with an increase about 3% after 14 days of refrigeration storage while the content of saturated fatty acids was at the same level. Helium low-pressure plasma does not induce oxidative processes. Application of this decontamination technique while maintaining product quality is possible in food industry. © The Author(s) 2015.

  13. Kajian konsentrasi kefir grain dan lama simpan dalam refrigerator terhadap kualitas kimiawi kefir rendah lemak

    Directory of Open Access Journals (Sweden)

    Manik Eirry Sawitri

    2012-03-01

    Full Text Available Abstract : 1, 2percent (G2dan 3 percent (G3of milk volume and the second factor was storage time in refrigerator which were 0day(L0,7days(L7,14days(L14, 21 days(L21 and 28 days(L28 Keywords: kefir grains, storage time, refrigerator, low fat kefir . The variables measured were fat, protein, and alcohol content of kefir. Data were analyzed by analysis of variance and continued with Duncan. The results of research showed that concentration of kefir grains and storage time in refrigerator had highly significant effect (P0,05 on fat content of kefir. Interaction between both treatments had highly significant effect (P<0,01 on alcohol content of kefir. The conclusion of this research was apply 1 percent of kefir grains and maximum storage time in refrigerator for 21 days to produce kefir which appropriate with standard of fermentation milk. The objective of this research was to find out the influence of low fat milk in kefir processing with examined concentration on kefir grains and storage time in refrigerator to the fat, protein and alcohol content. This research was also to determined the concentration of kefir grains which appropriate to the standard of fermentation milk and as an information for practician and industry related to the research product. The materials used kefir that made from low fat milk (1% fat content, the research method was using Factorial Randomized Block Design (3X5. The first factor was concentration of kefir grains which were 1 percent(G

  14. Solar-Powered Refrigeration System

    Science.gov (United States)

    Ewert, Michael K. (Inventor); Bergeron, David J., III (Inventor)

    2002-01-01

    A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

  15. Solar Powered Refrigeration System

    Science.gov (United States)

    Ewert, Michael K. (Inventor); Bergeron, David J., III (Inventor)

    2002-01-01

    A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

  16. Integrated heat exchanger design for a cryogenic storage tank

    Energy Technology Data Exchange (ETDEWEB)

    Fesmire, J. E.; Bonner, T.; Oliveira, J. M.; Johnson, W. L.; Notardonato, W. U. [NASA Kennedy Space Center, Cryogenics Test Laboratory, NE-F6, KSC, FL 32899 (United States); Tomsik, T. M. [NASA Glenn Research Center, 21000 Brookpark Road, Cleveland, OH 44135 (United States); Conyers, H. J. [NASA Stennis Space Center, Building 3225, SSC, MS 39529 (United States)

    2014-01-29

    Field demonstrations of liquid hydrogen technology will be undertaken for the proliferation of advanced methods and applications in the use of cryofuels. Advancements in the use of cryofuels for transportation on Earth, from Earth, or in space are envisioned for automobiles, aircraft, rockets, and spacecraft. These advancements rely on practical ways of storage, transfer, and handling of liquid hydrogen. Focusing on storage, an integrated heat exchanger system has been designed for incorporation with an existing storage tank and a reverse Brayton cycle helium refrigerator of capacity 850 watts at 20 K. The storage tank is a 125,000-liter capacity horizontal cylindrical tank, with vacuum jacket and multilayer insulation, and a small 0.6-meter diameter manway opening. Addressed are the specific design challenges associated with the small opening, complete modularity, pressure systems re-certification for lower temperature and pressure service associated with hydrogen densification, and a large 8:1 length-to-diameter ratio for distribution of the cryogenic refrigeration. The approach, problem solving, and system design and analysis for integrated heat exchanger are detailed and discussed. Implications for future space launch facilities are also identified. The objective of the field demonstration will be to test various zero-loss and densified cryofuel handling concepts for future transportation applications.

  17. Advanced storage concepts for solar and low energy buildings, IEA-SHC Task 32. Slutrapport

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, J.M.; Andersen, Elsa; Furbo, S.

    2008-01-15

    This report reports on the results of the activities carried through in connection with the Danish part of the IEA SHC Task 32 project: Advanced Storage Concepts for Solar and Low Energy Buildings. The Danish involvement has focused on Subtask C: Storage Concepts Based on Phase Change Materials and Subtask D: Storage Concepts Based on Advanced Water Tanks and Special Devices. The report describes activities concerning heat-of-fusion storage and advanced water storage. (BA)

  18. The hydrogen mine introduction initiative

    Energy Technology Data Exchange (ETDEWEB)

    Betournay, M.C.; Howell, B. [Natural Resources Canada, Ottawa, ON (Canada). CANMET Mining and Mineral Sciences Laboratories

    2009-07-01

    In an effort to address air quality concerns in underground mines, the mining industry is considering the use fuel cells instead of diesel to power mine production vehicles. The immediate issues and opportunities associated with fuel cells use include a reduction in harmful greenhouse gas emissions; reduction in ventilation operating costs; reduction in energy consumption; improved health benefits; automation; and high productivity. The objective of the hydrogen mine introduction initiative (HMII) is to develop and test the range of fundamental and needed operational technology, specifications and best practices for underground hydrogen power applications. Although proof of concept studies have shown high potential for fuel cell use, safety considerations must be addressed, including hydrogen behaviour in confined conditions. This presentation highlighted the issues to meet operational requirements, notably hydrogen production; delivery and storage; mine regulations; and hydrogen behaviour underground. tabs., figs.

  19. Magnetic refrigerator for hydrogen liquefaction

    Energy Technology Data Exchange (ETDEWEB)

    Numazawa, T [National Institute for Materials Science, Tsukuba (Japan); Kamlya, K. [Japan Atomic Energy Agency, Naka (Japan); Utaki, T. [Osaka University, Osaka (Japan); Matsumoto, K. [Kanazawa University, Kanazawa (Japan)

    2013-06-15

    This paper reviews the development status of magnetic refrigeration system for hydrogen liquefaction. There is no doubt that hydrogen is one of most important energy sources in the near future. In particular, liquid hydrogen can be utilized for infrastructure construction consisting of storage and transportation. Liquid hydrogen is in cryogenic temperatures and therefore high efficient liquefaction method must be studied. Magnetic refrigeration which uses the magneto-caloric effect has potential to realize not only the higher liquefaction efficiency > 50 %, but also to be environmentally friendly and cost effective. Our hydrogen magnetic refrigeration system consists of Carnot cycle for liquefaction stage and AMR (active magnetic regenerator) cycle for precooling stages. For the Carnot cycle, we develop the high efficient system > 80 % liquefaction efficiency by using the heat pipe. For the AMR cycle, we studied two kinds of displacer systems, which transferred the working fluid. We confirmed the AMR effect with the cooling temperature span of 12 K for 1.8 T of the magnetic field and 6 second of the cycle. By using the simulation, we estimate the total efficiency of the hydrogen liquefaction plant for 10 kg/day. A FOM of 0.47 is obtained in the magnetic refrigeration system operation temperature between 20 K and 77 K including LN2 work input.

  20. Design research of uranium mine borehole database

    International Nuclear Information System (INIS)

    Xie Huaming; Hu Guangdao; Zhu Xianglin; Chen Dehua; Chen Miaoshun

    2008-01-01

    With short supply of energy sources, exploration of uranium mine have been enhanced, but data storage, analysis and usage of exploration data of uranium mine are not highly computerized currently in China, the data is poor shared and used that it can not adapt the need of production and research. It will be well done, if the data are stored and managed in a database system. The concept structure design, logic structure design and data integrity checks are discussed according to the demand of applications and the analysis of exploration data of uranium mine. An application of the database is illustrated finally. (authors)

  1. Performance Analysis of Multipurpose Refrigeration System (MRS on Fishing Vessel

    Directory of Open Access Journals (Sweden)

    Ust Y.

    2016-04-01

    Full Text Available The use of efficient refrigerator/freezers helps considerably to reduce the amount of the emitted greenhouse gas. A two-circuit refrigerator-freezer cycle (RF reveals a higher energy saving potential than a conventional cycle with a single loop of serial evaporators, owing to pressure drop in each evaporator during refrigeration operation and low compression ratio. Therefore, several industrial applications and fish storage systems have been utilized by using multipurpose refrigeration cycle. That is why a theoretical performance analysis based on the exergetic performance coefficient, coefficient of performance (COP, exergy efficiency and exergy destruction ratio criteria, has been carried out for a multipurpose refrigeration system by using different refrigerants in serial and parallel operation conditions. The exergetic performance coefficient criterion is defined as the ratio of exergy output to the total exergy destruction rate (or loss rate of availability. According to the results of the study, the refrigerant R32 shows the best performance in terms of exergetic performance coefficient, COP, exergy efficiency, and exergy destruction ratio from among the other refrigerants (R1234yf, R1234ze, R404A, R407C, R410A, R143A and R502. The effects of the condenser, freezer-evaporator and refrigerator-evaporator temperatures on the exergetic performance coefficient, COP, exergy efficiency and exergy destruction ratios have been fully analyzed for the refrigerant R32.

  2. Net haemoglobin increase from reinfusion of refrigerated vs. frozen red blood cells after autologous blood transfusions

    DEFF Research Database (Denmark)

    Ashenden, M; Mørkeberg, Jakob Sehested

    2011-01-01

    BACKGROUND AND OBJECTIVES  Two main blood storage procedures can be used for storing red blood cells: refrigeration and freezing. Nevertheless, the efficiency of these procedures measured as the increase in haemoglobin after reinfusion compared with baseline has never been examined. The main...... objective was to examine which storage procedure yielded the largest increase in circulating haemoglobin after reinfusion compared to baseline. MATERIALS AND METHODS  Equal volumes of blood from 15 men were withdrawn and stored either frozen or refrigerated as packed red blood cells. Serial measures...... of circulating haemoglobin by carbon monoxide rebreathing provided an opportunity to monitor recovery from anaemia, as well as the net increase in circulating haemoglobin after transfusion. RESULTS  The post-thaw yield of haemoglobin in the bags was 72% after refrigerated storage compared with only 52% after...

  3. Gamma irradiation in the control of pathogenic bacteria in refrigerated ground chicken meat

    Directory of Open Access Journals (Sweden)

    Spoto Marta Helena Filet

    2000-01-01

    Full Text Available This work evaluated the effect of gamma radiation on reducting the population of Staphylococcus aureus, Escherichia coli and Salmonella typhimurium in ground chicken breast stored under refrigeration. The experiment included a control and 4 doses of gamma radiation (2.0, 4.0, 6.0 and 8.0 kGy along with 5 periods of storage under refrigeration (1, 7, 14, 21 and 28 days. Samples of ground chicken breast were inoculated with Staphylococcus aureus (ATCC 14458, Escherichia coli (ATCC 11105 and Salmonella typhimurium (ATCC 0626, irradiated at temperatures between 4 and 8°C and stored under refrigeration (5°C for 28 days. The increased radiation dose and period of storage under refrigeration caused a reduction of Staphylococcus aureus, Escherichia coli and Salmonella typhimurium populations in the ground chicken breast. Mean radiation D values determined for Staphylococcus aureus and Escherichia coli were 0.41 and 0.72 kGy, respectively. Gamma irradiation was an effective treatment for chicken meat conservation because the radiation dose of 6.0 kGy kept the ground chicken breast within the microbiological limits established by the Brazilian legislation, for up to 28 days under refrigeration.

  4. Gamma irradiation in the control of pathogenic bacteria in refrigerated ground chicken meat

    International Nuclear Information System (INIS)

    Spoto, Marta Helena Fillet; Alcarde, Andre Ricardo; Gurgel, Maria Silvia do Amaral; Blumer, Lucimara; Walder, Julio Marcos Melges; Domarco, Rachel Elisabeth; Gallo, Claudio Rosa

    2000-01-01

    This work evaluated the effect of gamma radiation on reducing the population of Staphylococcus aureus, Escherichia coli nd Salmonella typhimurium in ground chicken breast stored under refrigeration. The experiment included a control and 4 doses of gamma radiation ( 2.0, 4.0, 6.0 and 8.0 kGy) along with 5 periods of storage under refrigeration ( 1, 7 14, 21 and 28 days). Samples of ground chicken breast were inoculated with Staphylococcus aureus (ATCC 14458), Escherichia coli (ATCC 11105) and Salmonella typhimurium (ATCC 0626), irradiated at temperatures between 4 and 8 deg C and stored under refrigeration (5 deg C) for 28 days. The increased radiation dose and period of storage under refrigeration caused a reduction of Staphylococcus aureus, Escherichia coli and Salmonella typhimurium populations in the ground chicken breast. Mean radiation D values determined for Staphylococcus aureus and Escherichia coli were 0.41 and 0.72 kGy, respectively. Gamma irradiation was an effective treatment for chicken meat conservation because the radiation dose of 6.0 kGy kept the ground chicken breast within the microbiological limits established by the Brazilian legislation for up to 28 days under refrigeration. (author)

  5. Physical, chemical, microbiological and sensorial behaviour evolution of non cooked pressed cheese paste while in refrigerated storage, made with red chilli powder, treated by heat or ionization

    International Nuclear Information System (INIS)

    Iben El Hadj Mohamed, A.

    1998-01-01

    The evolution of different physical, chemical, microbiological and sensorial characteristics of a Tunisian manufactured cheese made of non cooked pressed cheese paste with red chilli powder treated by heat, was measured while in refrigerated storage and compared to the one treated by ionization (author)

  6. Load management for refrigeration systems: Potentials and barriers

    Energy Technology Data Exchange (ETDEWEB)

    Grein, Arne, E-mail: a.grein@tu-berlin.de [University of Technology Berlin, Institute for Energy Technology, Department of Energy Systems, Einsteinufer 25 (TA8), 10587 Berlin (Germany); Pehnt, Martin [Institute for Energy and Environmental Research Heidelberg (ifeu), Wilckensstr. 3, 69120 Heidelberg (Germany)

    2011-09-15

    As a strategy to deal with the increasing intermittent input of renewable energy sources in Germany, the adaptation of power consumption is complementary to power-plant regulation, grid expansion and physical energy storage. One demand sector that promises strong returns for load management efforts is cooling and refrigeration. In these processes, thermal inertia provides a temporal buffer for shifting and adjusting the power consumption of cooling systems. We have conducted an empirical investigation to obtain a detailed and time-resolved bottom-up analysis of load management for refrigeration systems in the city of Mannheim, Germany. We have extrapolated our results to general conditions in Germany. Several barriers inhibit the rapid adoption of load management strategies for cooling systems, including informational barriers, strict compliance with legal cooling requirements, liability issues, lack of technical experience, an inadequate rate of return and organizational barriers. Small commercial applications of refrigeration in the food-retailing and cold storage in hotels and restaurants are particularly promising starting points for intelligent load management. When our results are applied to Germany, suitable sectors for load management have theoretical and achievable potential values of 4.2 and 2.8 GW, respectively, amounting to about 4-6% of the maximum power demand in Germany. - Highlights: > Potential and barriers for implementation of load shifting for refrigeration. > Empirical investigation for time-resolved bottom-up analysis in Mannheim, Germany. > Suitable sectors and further recommendations for introducing load management.> Extrapolation of results from local to national level.

  7. Load management for refrigeration systems: Potentials and barriers

    International Nuclear Information System (INIS)

    Grein, Arne; Pehnt, Martin

    2011-01-01

    As a strategy to deal with the increasing intermittent input of renewable energy sources in Germany, the adaptation of power consumption is complementary to power-plant regulation, grid expansion and physical energy storage. One demand sector that promises strong returns for load management efforts is cooling and refrigeration. In these processes, thermal inertia provides a temporal buffer for shifting and adjusting the power consumption of cooling systems. We have conducted an empirical investigation to obtain a detailed and time-resolved bottom-up analysis of load management for refrigeration systems in the city of Mannheim, Germany. We have extrapolated our results to general conditions in Germany. Several barriers inhibit the rapid adoption of load management strategies for cooling systems, including informational barriers, strict compliance with legal cooling requirements, liability issues, lack of technical experience, an inadequate rate of return and organizational barriers. Small commercial applications of refrigeration in the food-retailing and cold storage in hotels and restaurants are particularly promising starting points for intelligent load management. When our results are applied to Germany, suitable sectors for load management have theoretical and achievable potential values of 4.2 and 2.8 GW, respectively, amounting to about 4-6% of the maximum power demand in Germany. - Highlights: → Potential and barriers for implementation of load shifting for refrigeration. → Empirical investigation for time-resolved bottom-up analysis in Mannheim, Germany. → Suitable sectors and further recommendations for introducing load management.→ Extrapolation of results from local to national level.

  8. Comparison of cask and drywell storage concepts for a monitored retrievable storage/interim storage system

    International Nuclear Information System (INIS)

    Rasmussen, D.E.

    1982-12-01

    The Department of Energy, through its Richland Operations Office is evaluating the feasibility, timing, and cost of providing a federal capability for storing the spent fuel, high-level wastes, and transuranic wastes that DOE may be obligated by law to manage until permanent waste disposal facilities are available. Three concepts utilizing a monitored retrievable storage/interim storage (MRS/IS) facility have been developed and analyzed. The first concept, co-location with a reprocessing plant, has been developed by staff of Allied General Nuclear Services. the second concept, a stand-alone facility, has been developed by staff of the General Atomic Company. The third concept, co-location with a deep geologic repository, has been developed by the Pacific Northwest Laboratory with the assistance of the Westinghouse Hanford Company and Kaiser Engineers. The objectives of this study are: to develop preconceptual designs for MRS/IS facilities: to examine various issues such as transportation of wastes, licensing of the facilities, and environmental concerns associated with operation of such facilities; and to estimate the life-cycle costs of the facilities when operated in response to a set of scenarios that define the quantities and types of waste requiring storage in specific time periods, generally spanning the years 1989 to 2037. Three scenarios are examined to develop estimates of life-cycle costs for the MRS/IS facilities. In the first scenario, the reprocessing plant is placed in service in 1989 and HLW canisters are stored until a repository is opened in the year 1998. Additional reprocessing plants and repositories are placed in service at intervals as needed to meet the demand. In the second scenario, the reprocessing plants are delayed in starting operations by 10 years, but the repositories open on schedule. In the third scenario, the repositories are delayed 10 years, but the reprocessing plants open on schedule

  9. Comparison of cask and drywell storage concepts for a monitored retrievable storage/interim storage system

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, D.E.

    1982-12-01

    The Department of Energy, through its Richland Operations Office is evaluating the feasibility, timing, and cost of providing a federal capability for storing the spent fuel, high-level wastes, and transuranic wastes that DOE may be obligated by law to manage until permanent waste disposal facilities are available. Three concepts utilizing a monitored retrievable storage/interim storage (MRS/IS) facility have been developed and analyzed. The first concept, co-location with a reprocessing plant, has been developed by staff of Allied General Nuclear Services. the second concept, a stand-alone facility, has been developed by staff of the General Atomic Company. The third concept, co-location with a deep geologic repository, has been developed by the Pacific Northwest Laboratory with the assistance of the Westinghouse Hanford Company and Kaiser Engineers. The objectives of this study are: to develop preconceptual designs for MRS/IS facilities: to examine various issues such as transportation of wastes, licensing of the facilities, and environmental concerns associated with operation of such facilities; and to estimate the life-cycle costs of the facilities when operated in response to a set of scenarios that define the quantities and types of waste requiring storage in specific time periods, generally spanning the years 1989 to 2037. Three scenarios are examined to develop estimates of life-cycle costs for the MRS/IS facilities. In the first scenario, the reprocessing plant is placed in service in 1989 and HLW canisters are stored until a repository is opened in the year 1998. Additional reprocessing plants and repositories are placed in service at intervals as needed to meet the demand. In the second scenario, the reprocessing plants are delayed in starting operations by 10 years, but the repositories open on schedule. In the third scenario, the repositories are delayed 10 years, but the reprocessing plants open on schedule.

  10. Underground rock storage concepts for natural gas and LPG in Finland

    International Nuclear Information System (INIS)

    Saerkkae, P.

    1990-01-01

    Natural gas storage concepts are developed in Finland for both deep, unlined rock storages and cryogenic lined, near-surface storages. For butane and propane, Neste Oy has two unlined rock storages in Porvoo. Up to now, experiences are good on storage of LPG in rock temperature and higher than hydrostatic pressure. (author). 3 refs, 8 figs

  11. Design calculations for MAW storage experiment in the Asse salt mine

    International Nuclear Information System (INIS)

    Nipp, H.K.

    1987-01-01

    Several thermal pre-calculations examine what heat release is necessary in the storage experiment in order to produce a temperature level relevant to final storage at the edge of the borehole. It was found that the initial power must be 350-400 W/m. The thermo-mechanical design calculations are done on symmetrical equivalent models, in order to avoid a genuine spatial calculation. The results of the calculations show that the recovery of the radioactive waste is guaranteed over the whole experimental period, as the selected convergence space of 11 or 14 cm is sufficiently large. From the rock mechanics point of view, the MAW storage experiment is designed for the 800 m seam of the Asse mine, as no critical stresses are expected from calculations for the area of the borehole. (orig./RB) [de

  12. Intermittent Solar Ammonia Absorption Cycle (ISAAC) refrigeration for lesser developed countries

    Science.gov (United States)

    Erickson, Donald C.

    1990-02-01

    The Intermittent Solar Ammonia Absorption Cycle (ISAAC) refrigerator is a solar thermal technology which provides low cost, efficient, reliable ice-making to areas without ready access to electricity. An ISAAC refrigeration system consists of a compound parabolic solar collector, two pressure vessels, a condenser, a cold box or refrigerated space, and simple connective piping -- no moving parts or electrical components. Most parts are simple construction or plumbing grade materials, locally available in many remote areas. This technology has numerous potential benefits in lesser developed countries both by providing a cheap, reliable source of ice, and, since manufacture requires only semi-skilled labor, a source of employment to the local economy. Applications include vaccine storage for health care clinics; fish, meat, and dairy product storage; and personal consumption. Importantly, this technology increases the quality of life for people in lesser developed countries without depleting fossil fuel resources or increasing the release of greenhouse gases such as CO2 and chlorofluorocarbons.

  13. Some elementary concepts of radiation health and safety in underground uranium mines

    International Nuclear Information System (INIS)

    Bigu, J.

    1980-02-01

    Some elementary concepts of radiation health and safety in underground uranium mines are discussed. This report reviews the main radiation sources which contribute to the contamination of mine atmospheres and hence to the exposure of mine workers. A brief discussion of the biological effects of ionizing radiation, with special reference to radon and its progeny, is followed by the introduction of the presently accepted radiation indexes for radiation hazard (WL) and radiation exposure (WLM). Finally, a succinct review of the available techniques for radiation control and monitoring in underground uranium mines is complemented by a discussion of various methods of personnel radiation protection, including the use of respirators, job rotation, personnel dosimetry and medical surveillance

  14. Cooling, freezing and heating with the air cycle: air as the ultimate green refrigerant

    NARCIS (Netherlands)

    Verschoor, M.J.E.

    2000-01-01

    Due to the recent concern about the damage that CFCs cause to the environment (ozone layer, global warming) and the absence of commonly acceptable alternative refrigerants, the search for alternative refrigeration concepts is going on. Air as refrigerant in the Joule-Brayton cycle (air cycle) is one

  15. Design of a large 2.0 k refrigerator for CEBAF

    International Nuclear Information System (INIS)

    Parish, H.; Hood, C.; Kreinbrink, K.; Appleton, W.; Gistau, G.

    1991-01-01

    The CEBAF refrigerator is designed to produce 4,620 watts of refrigeration at 2.0 K, another 180 watts at 2.14 K plus 4.5 K liquid and higher temperature cooling for shields. Several design features are described, including a modular concept for the 2 K and 4.5 K refrigerator sections and the use of multistage centrifugal cryogenic compressors to achieve the 2 K. The development program for the centrifugal cryogenic compressors is discussed. Some startup information is also provided

  16. Effect of curing ingredients and vacuum packaging on the physico-chemical and storage quality of ready-to-eat Vawksa rep (smoked pork product) during refrigerated storage.

    Science.gov (United States)

    Deuri, Deepshikha; Hazarika, Pragati; Singh, Tarun Pal; Chhangte, Lalchamliani; Singh, Parminder; Talukder, Suman

    2016-06-01

    The present study was conducted for the development of ready-to-eat Vawksa rep (smoked pork product) and to study the synergistic effect of curing ingredients and vacuum packaging on the physico-chemical and storage quality during refrigerated storage at (4°C±1°C) for 15 days. Four different batches of Vawksa rep samples were prepared, i.e., T-1 (uncured, first cooked at 121°C for 15 min, and then smoked at 120°C for 30 min), T-2 (uncured, cooked, and smoked simultaneously at 120°C for 45 min), T-3 (cured, first cooked at 121°C for 15 min, and then smoked at 120°C for 30 min), and T-4 (cured, cooked, and smoked simultaneously at 120°C for 45 min). Cooking yield was significantly higher (pproduct) could be prepared easily with little technology up-gradation and with a negligible escalation of production cost.

  17. Low Global Warming Potential Refrigerants for Commercial Refrigeration Systems

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, Brian A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sharma, Vishaldeep [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-06-01

    Supermarket refrigeration systems account for approximately 50% of supermarket energy use, placing this class of equipment among the highest energy consumers in the commercial building domain. In addition, the commonly used refrigeration system in supermarket applications is the multiplex direct expansion (DX) system, which is prone to refrigerant leaks due to its long lengths of refrigerant piping. This leakage reduces the efficiency of the system and increases the impact of the system on the environment. The high Global Warming Potential (GWP) of the hydrofluorocarbon (HFC) refrigerants commonly used in these systems, coupled with the large refrigerant charge and the high refrigerant leakage rates leads to significant direct emissions of greenhouse gases into the atmosphere. Environmental concerns are driving regulations for the heating, ventilating, air-conditioning and refrigeration (HVAC&R) industry towards lower GWP alternatives to HFC refrigerants. Existing lower GWP refrigerant alternatives include hydrocarbons, such as propane (R-290) and isobutane (R-600a), as well as carbon dioxide (R-744), ammonia (R-717), and R-32. In addition, new lower GWP refrigerant alternatives are currently being developed by refrigerant manufacturers, including hydrofluoro-olefin (HFO) and unsaturated hydrochlorofluorocarbon (HCFO) refrigerants. The selection of an appropriate refrigerant for a given refrigeration application should be based on several factors, including the GWP of the refrigerant, the energy consumption of the refrigeration system over its operating lifetime, and leakage of refrigerant over the system lifetime. For example, focusing on energy efficiency alone may overlook the significant environmental impact of refrigerant leakage; while focusing on GWP alone might result in lower efficiency systems that result in higher indirect impact over the equipment lifetime. Thus, the objective of this Collaborative Research and Development Agreement (CRADA) between

  18. Method and refrigerants for replacing existing refrigerants in centrifugal compressors

    International Nuclear Information System (INIS)

    Kopko, W.L.

    1991-01-01

    This patent describes a method for replacing an existing refrigerant in a centrifugal compressor. It comprises selecting a desired impeller Mach number for the centrifugal compressor; selecting a base refrigerant constituent; combining at least one additive refrigerant constituent with the base refrigerant constituent to form a replacement refrigerant having at least one physical or chemical property different from the existing refrigerant and substantially providing the desired impeller Mach number in the centrifugal compressor; and replacing the existing refrigerant with the replacement refrigerant

  19. Status of spent fuel dry storage concepts: concerns, issues and developments

    International Nuclear Information System (INIS)

    1985-11-01

    This report is intended to provide the reader with a general understanding of the various dry storage concepts and facilities required to support them. The outstanding technical concerns relative to dry storage installations, as well as, past and planned demonstration programs are briefly described. Such other activities as the development and approval of a design criteria standard is presented. An updated review of the cost of the various concepts are discussed

  20. Trigenerative micro compressed air energy storage: Concept and thermodynamic assessment

    International Nuclear Information System (INIS)

    Facci, Andrea L.; Sánchez, David; Jannelli, Elio; Ubertini, Stefano

    2015-01-01

    Highlights: • The trigenerative-CAES concept is introduced. • The thermodynamic feasibility of the trigenerative-CAES is assessed. • The effects of the relevant parameter on the system performances are dissected. • Technological issues on the trigenerative-CAES are highlighted. - Abstract: Energy storage is a cutting edge front for renewable and sustainable energy research. In fact, a massive exploitation of intermittent renewable sources, such as wind and sun, requires the introduction of effective mechanical energy storage systems. In this paper we introduce the concept of a trigenerative energy storage based on a compressed air system. The plant in study is a simplified design of the adiabatic compressed air energy storage and accumulates mechanical and thermal (both hot and cold) energy at the same time. We envisage the possibility to realize a relatively small size trigenerative compressed air energy storage to be placed close to the energy demand, according to the distributed generation paradigm. Here, we describe the plant concept and we identify all the relevant parameters influencing its thermodynamic behavior. Their effects are dissected through an accurate thermodynamic model. The most relevant technological issues, such as the guidelines for a proper choice of the compressor, expander and heat exchangers are also addressed. Our results show that T-CAES may have an interesting potential as a distributed system that combines electricity storage with heat and cooling energy production. We also show that the performances are significantly influenced by some operating and design parameters, whose feasibility in real applications must be considered.

  1. Thermal investigations of a room temperature magnetic refrigerator

    Energy Technology Data Exchange (ETDEWEB)

    Smaili, Arezki; Chiba, Younes [Ecole Nationale Polytechnique d' Alger (Algeria)], email: arezki.smaili@enp.edu.dz

    2011-07-01

    Magnetic refrigeration is a concept based on the magnetocaloric effect that some materials exhibit when the external magnetic field changes. The aim of this paper is to assess the performance of a numerical model in predicting parameters of an active magnetic regenerator refrigerator. Numerical simulations were conducted to perform a thermal analysis on an active magnetic regenerator refrigerator operating near room temperature with and without applied cooling load. Curves of temperature span, cooling capacity and thermal efficiency as functions of the operating conditions were drawn and are presented in this paper. Results showed that at fixed frequency Ql versus mf has an optimum and COP was increased with cycle frequency values. This study demonstrated that the proposed numerical model could be used to predict parameters of an active magnetic regenerator refrigerator as it provides consistent results.

  2. Effects of Freeze-dried Mulberry on Antioxidant Activities and Fermented Characteristics of Yogurt during Refrigerated Storage

    Science.gov (United States)

    2015-01-01

    This study investigated the effect of added freeze-dried mulberry fruit juice (FDMJ) (1, 3 and 5%) on the antioxidant activity and fermented characteristic of yogurt during refrigerated storage. A decrease in pH of yogurt and increase in acidity was observed during fermentation. The yogurts with FDMJ exhibited faster rate of pH reduction than control. Initial lactic acid bacteria count of yogurt was 6.49-6.94 Log CFU/g and increased above 9 Log CFU/g in control and 1% in FDMJ yogurt for 24 h. The total polyphenol and anthocyanin content of FDMJ yogurt was higher than that of control due to the presence of phytochemical contents in mulberry. Moreover, antioxidant activity such as DPPH and reducing power was highest 5% FDMJ yogurt. During cold storage, pH decreased or remained constant in all yogurts with values ranging from 4.08 to 4.78 units. In sensory evaluation, the score of 1% FDMJ yogurt was ranked higher when compared with other yogurts. It is proposed that mulberry fruit juice powder can be used to improve sensory evaluation and enhance functionality of yogurt. PMID:26877641

  3. Effects of Freeze-dried Mulberry on Antioxidant Activities and Fermented Characteristics of Yogurt during Refrigerated Storage.

    Science.gov (United States)

    Sung, Jung-Min; Kim, Young-Boong; Kum, Jun-Seok; Choi, Yun-Sang; Seo, Dong-Ho; Choi, Hyun-Wook; Park, Jong-Dae

    2015-01-01

    This study investigated the effect of added freeze-dried mulberry fruit juice (FDMJ) (1, 3 and 5%) on the antioxidant activity and fermented characteristic of yogurt during refrigerated storage. A decrease in pH of yogurt and increase in acidity was observed during fermentation. The yogurts with FDMJ exhibited faster rate of pH reduction than control. Initial lactic acid bacteria count of yogurt was 6.49-6.94 Log CFU/g and increased above 9 Log CFU/g in control and 1% in FDMJ yogurt for 24 h. The total polyphenol and anthocyanin content of FDMJ yogurt was higher than that of control due to the presence of phytochemical contents in mulberry. Moreover, antioxidant activity such as DPPH and reducing power was highest 5% FDMJ yogurt. During cold storage, pH decreased or remained constant in all yogurts with values ranging from 4.08 to 4.78 units. In sensory evaluation, the score of 1% FDMJ yogurt was ranked higher when compared with other yogurts. It is proposed that mulberry fruit juice powder can be used to improve sensory evaluation and enhance functionality of yogurt.

  4. Selection of concepts for monitored retrievable storage of spent nuclear fuel and high-level radioactive wastes

    International Nuclear Information System (INIS)

    1984-04-01

    The monitored retrievable storage (MRS) concepts considered are: metal cask (stationary and transportable); concrete cask (sealed storage cask); concrete cask-in-trench; field drywell; tunnel drywell; open cycle vault; closed cycle vault; and tunnel rack vault. These concepts were compared primarily upon the relative performance of the storage units on seven criteria which together encompass the key considerations for selecting an MRS concept, namely their ability to satisfy the MRS mission requirements. These criteria were: safety and licensing; environmental impacts; socioeconomic impacts; siting requirements; cost; concept maturity; and flexibility. Evaluations of the candidate concepts indicate that all of the concepts could satisfactorily serve in an MRS facility. However, using the above criteria, the two concepts selected for further design studies are the concrete cask (primary concept), better entitled the sealed storage cask, and the field drywell (alternate concept). It was recognized that the transportable metal storage cask may be used to supplement at-reactor storage until such time as the repository or MRS becomes available. Consequently, a hybrid storage facility may be required (e.g., one using concrete casks or field drywells, with the capability of receiving and storing the transportable cask). Both the concrete cask and the field drywell concepts can easily accommodate the transportable cask. Further design efforts will ensure the compatibility of the MRS designs with the transportable cask

  5. A Note on Interfacing Object Warehouses and Mass Storage Systems for Data Mining Applications

    Science.gov (United States)

    Grossman, Robert L.; Northcutt, Dave

    1996-01-01

    Data mining is the automatic discovery of patterns, associations, and anomalies in data sets. Data mining requires numerically and statistically intensive queries. Our assumption is that data mining requires a specialized data management infrastructure to support the aforementioned intensive queries, but because of the sizes of data involved, this infrastructure is layered over a hierarchical storage system. In this paper, we discuss the architecture of a system which is layered for modularity, but exploits specialized lightweight services to maintain efficiency. Rather than use a full functioned database for example, we use light weight object services specialized for data mining. We propose using information repositories between layers so that components on either side of the layer can access information in the repositories to assist in making decisions about data layout, the caching and migration of data, the scheduling of queries, and related matters.

  6. Duration of red blood cell storage and inflammatory marker generation

    Science.gov (United States)

    Sut, Caroline; Tariket, Sofiane; Chou, Ming Li; Garraud, Olivier; Laradi, Sandrine; Hamzeh-Cognasse, Hind; Seghatchian, Jerard; Burnouf, Thierry; Cognasse, Fabrice

    2017-01-01

    Red blood cell (RBC) transfusion is a life-saving treatment for several pathologies. RBCs for transfusion are stored refrigerated in a preservative solution, which extends their shelf-life for up to 42 days. During storage, the RBCs endure abundant physicochemical changes, named RBC storage lesions, which affect the overall quality standard, the functional integrity and in vivo survival of the transfused RBCs. Some of the changes occurring in the early stages of the storage period (for approximately two weeks) are reversible but become irreversible later on as the storage is extended. In this review, we aim to decipher the duration of RBC storage and inflammatory marker generation. This phenomenon is included as one of the causes of transfusion-related immunomodulation (TRIM), an emerging concept developed to potentially elucidate numerous clinical observations that suggest that RBC transfusion is associated with increased inflammatory events or effects with clinical consequence. PMID:28263172

  7. Analysis of Refrigeration Equipment in School Nutrition Programs in the USDA/FNS Southwest Region

    Science.gov (United States)

    Webb, Virginia Susan

    2012-01-01

    Equipment to store foods at proper temperatures is critical to serving safe and nutritious meals in schools yet little is known about the amount or the adequacy of refrigerated storage in school nutrition programs. The purposes of this study were to identify the types and capacity of refrigeration equipment used in schools, determine the perceived…

  8. Performance of an auto refrigerant cascade refrigerator operating in gas refrigerant supply (GRS) mode with nitrogen-hydrocarbon and argon-hydrocarbon refrigerants

    Science.gov (United States)

    Gurudath Nayak, H.; Venkatarathnam, G.

    2009-07-01

    There is a worldwide interest in the development of auto refrigerant cascade (ARC) refrigerators operating with refrigerant mixtures. Both flammable and non-flammable refrigerant mixtures can be used in these systems. The performance of an ARC system with optimum nitrogen-hydrocarbon and argon-hydrocarbon mixtures between 90 and 160 K is presented in this paper.

  9. SolarChill - a solar PV refrigerator without battery

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, P.H.; Poulsen, S.; Katic, I. [Danish Technological Inst., Taastrup (Denmark)

    2004-07-01

    A solar powered refrigerator (SolarChill) has been developed in an international project involving Greenpeace International, GTZ, UNICEF, UNEP, WHO, industrial partners and Danish Technological Institute. The refrigerator is able to operate directly on solar PV panels, without battery or additional electronics, and is therefore suitable for locations where little maintenance and reliable operation is mandatory. The main objective of the SolarChill Project is to help deliver vaccines and refrigeration to the rural poor. To achieve this objective, the SolarChill Project developed - and plans to make freely available a versatile refrigeration technology that is environmentally sound, technologically reliable, and affordable. SolarChill does not use any fluorocarbons in its cooling system or in the insulation. For domestic and small business applications, another type of solar refrigerator is under development. This is an upright type, suitable for cool storage of food and beverages in areas where grid power is non-existent or unstable. The market potential for this type is thus present in industrialised countries as well as in countries under development. The unique feature of SolarChill is that energy is stored in ice instead of in batteries. An ice compartment keeps the cabinet at desired temperatures during the night. The paper describes the product development, possible SolarChill applications and experience with the two types of solar refrigerators, as well as results from the laboratory and field test. (orig.)

  10. Refrigeration Playbook: Natural Refrigerants; Selecting and Designing Energy-Efficient Commercial Refrigeration Systems That Use Low Global Warming Potential Refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Caleb [CTA Architects Engineers, Boise, ID (United States); Reis, Chuck [CTA Architects Engineers, Boise, ID (United States); Nelson, Eric [CTA Architects Engineers, Boise, ID (United States); Armer, James [CTA Architects Engineers, Boise, ID (United States); Arthur, Rob [CTA Architects Engineers, Boise, ID (United States); Heath, Richard [CTA Architects Engineers, Boise, ID (United States); Rono, James [CTA Architects Engineers, Boise, ID (United States); Hirsch, Adam [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Doebber, Ian [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-03-01

    This report provides guidance for selecting and designing energy efficient commercial refrigeration systems using low global warming potential refrigerants. Refrigeration systems are generally the largest energy end use in a supermarket type building, often accounting for more than half of a building's energy consumption.

  11. 2017 German refrigeration and air conditioning meeting. Proceedings; Deutsche Kaelte- und Klimatagung 2017. Tagungsbericht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2017-07-01

    This year's lecture programme includes 117 presentations in the five working departments of DKV and 10 lectures at the special event ''Energy-efficient air conditioning in data centres''. The main topics in the respective departments were: (1) Cryogenics: Space applications; Cryogenic plants; Cryomedicine and cryobiology; Components, developments; Processes and plants; Valves, design. (2) Basics: Evaporation, material values; evaporation, condensation; absorption; adsorption, latent storage; cycle simulation. (3) Components: CO{sub 2} plant engineering and components; refrigerants; process control, adsorption, sublimation and storage technology; refrigerating machine oils, heat exchangers and corrosion; components 4.0, sensors and control technology; simulation of plant processes. (4) Cold application: Application; Application / Natural Refrigerants; Mobile Applications Car; Mobile Applications; Supermarket / Efficiency; Optimization / Efficiency. (5) Air conditioning and heat pump applications: load shifting, smart home, flexibility; heat sources and industrial heat pumps; modelling, simulations; energy concepts heat pumps and photovoltaics; monitoring, evaluation; technology trends / working materials. Six papers are separately analyzed for this database. [German] Das Vortragsprogramm umfasst in diesem Jahr 117 Beitraege in den fuenf Arbeitsabteilungen des DKV und 10 Vortraege in der Sonderveranstaltung ''Energieeffiziente Klimatisierung in Rechenzentren''. Die Hauptthemen in den jeweiligen Arbeitsabteilungen waren: (1) Kryotechnik: Raumfahrtanwendungen; Kryo-Grossanlagen; Kryomedizin und Kryobiologie; Komponenten, Entwicklungen; Verfahren und Anlagen; Ventile, Auslegung. (2) Grundlagen: Verdampfung, Stoffwerte; Verdampfung, Kondensation; Absorption; Adsorption, Latentspeicher; Kreislaufsimulation. (3) Komponenten: CO{sub 2}-Anlagentechnik und Komponenten; Kaeltemittel; Prozessfuehrung, Adsorption, Sublimation und

  12. High pressure treatment changes spoilage characteristics and shelf life of Pacific oysters ( Crassostrea gigas) during refrigerated storage

    Science.gov (United States)

    Cao, Rong; Zhao, Ling; Liu, Qi

    2017-04-01

    The effects of high pressure (HP) treatment on spoilage characteristic and shelf life extension of Pacific oysters ( Crassostrea gigas) during refrigerated storage were studied. Results showed that HP treatment of 275 MPa for 3 min or 300 MPa for 2 min could achieve 100% full release of oyster adductor muscle, pressures higher than 350 MPa caused excessive release as the shells of oysters were broken, thus use of higher pressures should be cautious in oyster processing industry because of its adverse impact on the appearance of shells. HP treatment (300 MPa, 2 min) was proper for the shucking of Pacific oyster ( Crassostrea gigas) in China. This treatment caused no organoleptic disadvantage. Moreover, HP treatment resulted in obvious differences in biochemical spoilage indicators (pH, TVB-N and TBARS) changes and volatile compounds profile determined by electronic nose during storage. HP treatment (300 MPa, 2 min) also led to a reduction of aerobic bacterial count (APC) by 1.27 log cycles. Furthermore, the APC values of oysters treated by HP were always lower than those of the control samples during storage. Based on the organoleptic, biochemical and microbiological indicators, shelf life of 6-8 d for control and 12 d for HP-treated oysters could be expected. HP treatment showed great potential in oyster processing and preservation.

  13. Effects of Gelatin-Based Edible Films Enriched with Laurel Essential Oil on the Quality of Rainbow Trout (Oncorhynchus mykiss) Fillets During Refrigerated Storage

    OpenAIRE

    Tuba Baygar; Taçnur Baygar; Hatice Hasanhocaoglu; Cansu Metin; Yunus Alparslan

    2014-01-01

    The effects of gelatin films enriched with laurel leaf essential oil on the quality of rainbow trout (Oncorhynchus mykiss) during refrigerated storage at (4±1) °C were examined over a period of 26 days. Fish fillets were wrapped with 8 % gelatin films containing 0, 0.1 and 1 % (by volume per mass) of laurel essential oil and vacuum packaged. Sensory (raw and cooked fish), microbiological (total viable counts, psychrotrophic bacteria counts, Enterobacteriaceae and lactic acid bacteria) and ...

  14. Uranium ISR Mine Closure — General Concepts and Model-Based Simulation of Natural Attenuation for South-Australian Mine Sites

    Energy Technology Data Exchange (ETDEWEB)

    Jeuken, B.; Märten, H.; Woods, P., E-mail: horst.maerten@heathgate.com.au [Heathgate Resources Pty. Ltd. (Heathgate), Adelaide (Australia); Kalka, H.; Nicolai, J. [Umwelt- und Ingenieurtechnik GmbH Dresden (UIT), Dresden (Germany)

    2014-05-15

    Heathgate has demonstrated the effect of natural attenuation (NA) in post in-situ recovery (ISR) aquifer regions during the operation of the Beverley mine since 2001. Enhanced natural attenuation (ENA) has been considered as the key component of the mine closure concept for the new Beverley Four Mile (BFM) project, complemented by an extensive monitoring program. Data from batch and column tests for BFM core samples was used to calibrate a reactive transport model, whose application in conjunction with the hydrological modelling of the BFM aquifer has shown that NA will result in the restoration of the aquifer in time. ENA within a staged mine development program under the site-specific circumstances is discussed. (author)

  15. Low-cost concepts for dry transfer of spent fuel and waste between storage and transportation casks

    International Nuclear Information System (INIS)

    Schneider, K.L.

    1984-01-01

    The federal government may provide interim storage for spent fuel from commercial nuclear power reactors that have used up their available storage capacity. One of the leading candidate concepts for this interim storage is to place spent fuel in large metal shielding casks. The Federal Interim Storage (FIS) site may not have the capability to transfer spent fuel from transportation casks to storage casks and vice versa. Thus, there may be an incentive to construct a relatively inexpensive but reliable intercask transfer system for use at an FIS site. This report documents the results of a preliminary study of preconceptual design and analysis of four intercask transfer concepts. The four concepts are: a large shielded cylindrical turntable that contains an integral fuel handling machine (turntable concept); a shielded fuel handling machine under which shipping and storage casks are moved horizontally (shuttle concept); a small hot cell containing equipment for transferring fuel betwee shipping and storage casks (that enter and leave the cell on carts) in a bifurcated trench (trench concept) and a large hot cell, shielded by an earthen berm, that houses equipment for handling fuel between casks that enter and leave the cell on a single cart (igloo concept). Information derived for each of the concepts is operating, capital and relocation costs; implementation and relocation time requirements; and overall characteristics

  16. Evaluating the quality of the edible offal (heart, liver, kidney of rabbits (Flemish Giant breed during storage by refrigeration following the evolution of the pH

    Directory of Open Access Journals (Sweden)

    Gabriela FRUNZĂ

    2017-11-01

    Full Text Available The purpose of this paper was to determine the quality of the edible offal (heart, liver and kidney of rabbits (Flemish Giant breed during storage by refrigeration following the evolution of the pH, after slaughter, during maturation, to autolysis and alteration, from 27 individuals (15 males and 12 females. The rabbits had an average body weight of 11.5 kg being at the age of reproductive maturity (11-12 months. The pH evolution of the edible offal (heart, liver, kidney of rabbits (refrigerated at 20C was monitored during of 18 days after slaughter. The pH evolution had a fluctuant ascendant trend, quite similar for females and males, presenting insignificant differences by gender. At 24 h after slaughter, the mean values of pH of the main edible offal (from males and females had the highest average values to the kidneys 6.48, followed by the heart 6.32 and by the liver 6.23. The alteration occurred much faster in kidneys and was starting with the 13th day of storage, the pH being close to 6.8-7.

  17. A multi-purpose unit concept to integrate storage, transportation, and the engineered barrier system

    International Nuclear Information System (INIS)

    Hollaway, W.R.; Rozier, R.; Nitti, D.A.; Williams, J.R.

    1993-01-01

    The Multi-Purpose Unit (MPU) is a new concept for standardizing and integrating the waste management functions of spent fuel storage, transportation, and geologic disposal. The MPU concept would use one unit, composed of a relatively thick-walled inner canister with a multi-purpose overpack, to meet the requirements for storage in 10 CFR 72, transportation in 10 CFR 71, and the engineered barrier system in 10 CFR 60. The MPU concept differs from the recently proposed Multi-Purpose Canister (MPC) concept in that the MPU concept uses a single multi-purpose overpack for storage, transportation, and geologic disposal, while the MPC concept uses separate and unique overpacks for each of these system functions. A design concept for the MPU is presented along with an estimate of unit costs. An initial evaluation of overall system cost showed that the MPU concept could be economically competitive with the current reference system. The MPU concept provides the potential for significant reduction, simplification, and standardization of Civilian Radioactive Waste Management (CRWMS) facilities and operations, including those at the utilities, during waste acceptance and transportation, and at the Monitored Retrievable Storage (MRS) facility and the repository. The primary issues for the MPU concept relate to uncertainties with respect to licensing, and the programmatic risks associated with implementing the MPU concept before the repository design is finalized. The strong potential exhibited by the MPU concept demonstrates that this option merits additional development and should be considered in the next phase of work on multi-purpose concepts for the CRWMS

  18. A systems evaluation model for selecting spent nuclear fuel storage concepts

    International Nuclear Information System (INIS)

    Postula, F.D.; Finch, W.C.; Morissette, R.P.

    1982-01-01

    This paper describes a system evaluation approach used to identify and evaluate monitored, retrievable fuel storage concepts that fulfill ten key criteria for meeting the functional requirements and system objectives of the National Nuclear Waste Management Program. The selection criteria include health and safety, schedules, costs, socio-economic factors and environmental factors. The methodology used to establish the selection criteria, develop a weight of importance for each criterion and assess the relative merit of each storage system is discussed. The impact of cost relative to technical criteria is examined along with experience in obtaining relative merit data and its application in the model. Topics considered include spent fuel storage requirements, functional requirements, preliminary screening, and Monitored Retrievable Storage (MRS) system evaluation. It is concluded that the proposed system evaluation model is universally applicable when many concepts in various stages of design and cost development need to be evaluated

  19. Vitamin D2 Stability During the Refrigerated Storage of Ultraviolet B-Treated Cultivated Culinary-Medicinal Mushrooms.

    Science.gov (United States)

    Slawinska, Aneta; Fornal, Emilia; Radzki, Wojciech; Jablonska-Rys, Ewa; Parfieniuk, Ewa

    2017-01-01

    The effects of ultraviolet B (UVB) irradiation on the synthesis of vitamin D2 and its stability during refrigerated storage was determined in fresh cultivated culinary-medicinal mushrooms (Agaricus bisporus, Pleurotus ostreatus, and Lentinus edodes) after harvest. The irradiated mushrooms were stored at 4°C for up to 10 days. The concentrations of vitamin D2 and ergosterol were determined using ultrahigh-performance liquid chromatography/tandem mass spectrometry. The cultivated mushrooms not treated with UVB were devoid of vitamin D2. After UVB irradiation, we obtained mushrooms with a large amount of ergocalciferol. A. bisporus showed the lowest vitamin D2 content (3.55 ± 0.11 μg D2/g dry weight); P. ostreatus contained 58.96 ± 1.15 μg D2/g dry weight, and L. edodes contained 29.46 ± 2.21 μg/g dry weight. During storage at 4°C, the amount of vitamin D2 was gradually decreased in P. ostreatus and L. edodes, whereas in A. bisporus vitamin D2 gradually increased until the sixth day, then decreased. Mushrooms exposed to UVB radiation contain a significant amount of vitamin D2 and are therefore an excellent food source of vitamin D.

  20. Energy and Exergy Analysis of Ocean Compressed Air Energy Storage Concepts

    Directory of Open Access Journals (Sweden)

    Vikram C. Patil

    2018-01-01

    Full Text Available Optimal utilization of renewable energy resources needs energy storage capability in integration with the electric grid. Ocean compressed air energy storage (OCAES can provide promising large-scale energy storage. In OCAES, energy is stored in the form of compressed air under the ocean. Underwater energy storage results in a constant-pressure storage system which has potential to show high efficiency compared to constant-volume energy storage. Various OCAES concepts, namely, diabatic, adiabatic, and isothermal OCAES, are possible based on the handling of heat in the system. These OCAES concepts are assessed using energy and exergy analysis in this paper. Roundtrip efficiency of liquid piston based OCAES is also investigated using an experimental liquid piston compressor. Further, the potential of improved efficiency of liquid piston based OCAES with use of various heat transfer enhancement techniques is investigated. Results show that adiabatic OCAES shows improved efficiency over diabatic OCAES by storing thermal exergy in thermal energy storage and isothermal OCAES shows significantly higher efficiency over adiabatic and diabatic OCAES. Liquid piston based OCAES is estimated to show roundtrip efficiency of about 45% and use of heat transfer enhancement in liquid piston has potential to improve roundtrip efficiency of liquid piston based OCAES up to 62%.

  1. Multi-ejector concept for R-744 supermarket refrigerators; Multi-Ejektoren Konzept fuer R-744 Supermarkt-Kaelteanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Hafner, Armin [SINTEF Energy Research, Trondheim (Norway); Foersterling, Sven [TLK-Thermo GmbH, Braunschweig (Germany); Banasiak, Krzystof [Silesian Univ. of Technology, Gliwice (Poland)

    2012-07-01

    Supermarkets are commercial buildings with major energy consumption and contribute also to relatively large direct emissions of greenhouse (GHG) through emissions of refrigerants from the refrigeration plants and the air conditioning system installed. The huge majority of these systems, which are installed in European supermarkets, are applying HFC-404A as working fluid. Average annual leakage rates in Europe are in the range of 15-20 % of the total charge. Worldwide the figure is about 30 % and HCFC-22 being the main refrigerant in use. Restrictions on the use of synthetic refrigerants are coming into force in several countries. There is a need for a natural refrigerant which allows for a safe investment in efficient refrigeration systems which will not be forced to be retrofitted by legislation in the future. Systems applying R-744 as the only refrigerant have been developed and more than 500 supermarkets exist in Europe, mainly in northern and mid-European countries. However, the systems still have large potential in development with respect to energy efficiency, heat recovery and cost efficiency. The paper describes the calculation method to identify the possible annual energy savings for different supermarket systems layout. The adoption of non-controlled ejectors and additional function such as heat recovery are evaluated. Results show relevant improvements in system efficiency when heat recovery has been adopted. Ejector usage is not widely spread at the moment. Thus, a theoretical analysis applying the programming language Modelica has been carried out. (orig.)

  2. Effects of Extended Freezer Storage on the Integrity of Human Milk.

    Science.gov (United States)

    Ahrabi, Ali Faraghi; Handa, Deepali; Codipilly, Champa N; Shah, Syed; Williams, Janet E; McGuire, Mark A; Potak, Debra; Aharon, Grace Golda; Schanler, Richard J

    2016-10-01

    To examine the integrity (pH, bacterial counts, host defense factors, nutrient contents, and osmolality) of freshly expressed and previously refrigerated human milk subjected to long-term freezer storage. Mothers donated 100 mL of freshly expressed milk. Samples were divided into baseline, storage at -20°C (fresh frozen) for 1, 3, 6, and 9 months, and prior storage at +4°C for 72 hours (refrigerated frozen) before storage at -20°C for 1 to 9 months. Samples were analyzed for pH, total bacterial colony count, gram-positive and gram-negative colony counts, and concentrations of total protein, fat, nonesterified fatty acids, lactoferrin, secretory IgA, and osmolality. Milk pH, total bacterial colony count, and Gram-positive colony counts decreased significantly with freezer storage (P negative colony count decreased significantly over time (P human milk for 9 months at -20°C is associated with decreasing pH and bacterial counts, but preservation of key macronutrients and immunoactive components, with or without prior refrigeration for 72 hours. These data support current guidelines for freezer storage of human milk for up to 9 months for both freshly expressed and refrigerated milk. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. A Fault-Tolerant Radiation-Robust Mass Storage Concept for Highly Scaled Flash Memory

    Science.gov (United States)

    Fuchs, Cristian M.; Trinitis, Carsten; Appel, Nicolas; Langer, Martin

    2015-09-01

    Future spacemissions will require vast amounts of data to be stored and processed aboard spacecraft. While satisfying operational mission requirements, storage systems must guarantee data integrity and recover damaged data throughout the mission. NAND-flash memories have become popular for space-borne high performance mass memory scenarios, though future storage concepts will rely upon highly scaled flash or other memory technologies. With modern flash memory, single bit erasure coding and RAID based concepts are insufficient. Thus, a fully run-time configurable, high performance, dependable storage concept, requiring a minimal set of logic or software. The solution is based on composite erasure coding and can be adjusted for altered mission duration or changing environmental conditions.

  4. ENERGY EFFICIENCY, ENERGY SAVING POTENTIAL AND ENVIRONMENTAL IMPACT RESEARCH OF LPG CARRIER REFRIGERATION SYSTEM

    Directory of Open Access Journals (Sweden)

    V. О. Bedrosov

    2016-12-01

    Full Text Available Nowadays energy efficiency improvement and global warming are issues of current interest because of the natural resources depletion and extreme climate change. Thus, the problem of formation of strict regulations regarding emissions into the air arises. This paper presents the study of cascade refrigeration system for re-condensing of associated petroleum gas during sea transportation for LPG carrier. The structural optimization has been performed. LPG gas carriers with 266 000 m3 ethane capacity require 15 MW cascade refrigeration system for re-condensing if the temperature in the coastal LPG storage is -70°C, and the temperature for transported Ethan is maintained at  -75°C. For current storage conditions the required system cooling capacity is only 1,078 MW intended for the heat gain rejection from the environment during Ethane transportation. The replacement of ozone-depleting refrigerant R22 to alternative agents: R407C, R404A, R402A, R717, R290, R1270 was estimated. The results of analysis have shown that the proposed improvements can be used to optimize the LPG carrier cascade refrigeration system

  5. Knowledge based word-concept model estimation and refinement for biomedical text mining.

    Science.gov (United States)

    Jimeno Yepes, Antonio; Berlanga, Rafael

    2015-02-01

    Text mining of scientific literature has been essential for setting up large public biomedical databases, which are being widely used by the research community. In the biomedical domain, the existence of a large number of terminological resources and knowledge bases (KB) has enabled a myriad of machine learning methods for different text mining related tasks. Unfortunately, KBs have not been devised for text mining tasks but for human interpretation, thus performance of KB-based methods is usually lower when compared to supervised machine learning methods. The disadvantage of supervised methods though is they require labeled training data and therefore not useful for large scale biomedical text mining systems. KB-based methods do not have this limitation. In this paper, we describe a novel method to generate word-concept probabilities from a KB, which can serve as a basis for several text mining tasks. This method not only takes into account the underlying patterns within the descriptions contained in the KB but also those in texts available from large unlabeled corpora such as MEDLINE. The parameters of the model have been estimated without training data. Patterns from MEDLINE have been built using MetaMap for entity recognition and related using co-occurrences. The word-concept probabilities were evaluated on the task of word sense disambiguation (WSD). The results showed that our method obtained a higher degree of accuracy than other state-of-the-art approaches when evaluated on the MSH WSD data set. We also evaluated our method on the task of document ranking using MEDLINE citations. These results also showed an increase in performance over existing baseline retrieval approaches. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Demonstration of the Use of Remote Temperature Monitoring Devices in Vaccine Refrigerators in Haiti.

    Science.gov (United States)

    Cavallaro, Kathleen F; Francois, Jeannot; Jacques, Roody; Mentor, Derline; Yalcouye, Idrissa; Wilkins, Karen; Mueller, Nathan; Turner, Rebecca; Wallace, Aaron; Tohme, Rania A

    After the 2010 earthquake, Haiti committed to introducing 4 new antigens into its routine immunization schedule, which required improving its cold chain (ie, temperature-controlled supply chain) and increasing vaccine storage capacity by installing new refrigerators. We tested the feasibility of using remote temperature monitoring devices (RTMDs) in Haiti in a sample of vaccine refrigerators fueled by solar panels, propane gas, or electricity. We analyzed data from 16 RTMDs monitoring 24 refrigerators in 15 sites from March through August 2014. Although 5 of the 16 RTMDs exhibited intermittent data gaps, we identified typical temperature patterns consistent with refrigerator door opening and closing, propane depletion, thermostat insufficiency, and overstocking. Actual start-up, annual maintenance, and annual electricity costs for using RTMDs were $686, $179, and $9 per refrigerator, respectively. In Haiti, RTMD use was feasible. RTMDs could be prioritized for use with existing refrigerators with high volumes of vaccines and new refrigerators to certify their functionality before use. Vaccine vial monitors could provide additional useful information about cumulative heat exposure and possible vaccine denaturation.

  7. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1998-03-15

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to thermophysical properties, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air conditioning and refrigeration equipment. It also references documents addressing compatibility of refrigerants and lubricants with other materials.

  8. Refrigerator retirement and replacement programs : lessons learned and application to an Ontario wide program

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-05-15

    The best practices in refrigerator retirement programs in North America were identified in an effort to develop a concept for an Ontario-wide provincial refrigerator retirement program. The report focused on describing refrigerator retirement programs, namely those programs that focused on getting rid of old secondary refrigerators. The report excluded refrigerator replacement programs, which encourage householders to retire their refrigerators early and replace them with an energy star refrigerator. However, it was noted that in several regions, both replacement and retirement programs are offered at the same time. The report provided background information on energy use by refrigerators as well as refrigerator retirement and replacement programs. Types of refrigerator retirement and replacement programs and the environmental benefits of these programs were also described. The report also addressed the potential energy impact of an Ontario-wide refrigerator retirement program as well as consumer incentive and bounties initiatives to encourage households to retire units. Other topics covered in the report included the design of typical refrigerator retirement and replacement programs; collection and recycling of retired refrigerators; reported costs of refrigerator retirement and replacement programs; as well as marketing and advertising. The role of retailers and manufacturers and reported lessons learned from refrigerator retirement and replacement were also presented. 14 refs., 6 tabs., 6 appendices.

  9. Oxidative stability of pork emulsion containing tomato products and pink guava pulp during refrigerated aerobic storage.

    Science.gov (United States)

    Joseph, Serlene; Chatli, Manish K; Biswas, Ashim K; Sahoo, Jhari

    2014-11-01

    Lipid oxidation-induced quality problems can be minimized with the use of natural antioxidants. Antioxidant potential of tomato puree (10 %; T-1), tomato pulp (12.5 %; T-2), lyophilized tomato peel (6 %; T-3), and pink guava pulp (10 %; T-4) was evaluated in raw pork emulsion during refrigerated storage for 9 days under aerobic packaging. The lycopene and β-carotene content varied in pork emulsion as T-3 > T-1 > T-2 > T-4 and decreased (P emulsions than in control. Overall, incorporation of tomato products and pink guava pulp improved the visual colour and odour scores of raw pork emulsion. These results indicated that tomato products and guava pulp can be utilized as sources of natural antioxidants in raw pork products to minimize lipid oxidation, off-odour development, and surface discolouration.

  10. Towards Technological Approaches for Concept Maps Mining from Text

    Directory of Open Access Journals (Sweden)

    Camila Zacche Aguiar

    2018-04-01

    Full Text Available Concept maps are resources for the representation and construction of knowledge. They allow showing, through concepts and relationships, how knowledge about a subject is organized. Technological advances have boosted the development of approaches for the automatic construction of a concept map, to facilitate and provide the benefits of that resource more broadly. Due to the need to better identify and analyze the functionalities and characteristics of those approaches, we conducted a detailed study on technological approaches for automatic construction of concept maps published between 1994 and 2016 in the IEEE Xplore, ACM and Elsevier Science Direct data bases. From this study, we elaborate a categorization defined on two perspectives, Data Source and Graphic Representation, and fourteen categories. That study collected 30 relevant articles, which were applied to the proposed categorization to identify the main features and limitations of each approach. A detailed view on these approaches, their characteristics and techniques are presented enabling a quantitative analysis. In addition, the categorization has given us objective conditions to establish new specification requirements for a new technological approach aiming at concept maps mining from texts.

  11. Thermoacoustic refrigeration

    Science.gov (United States)

    Garrett, Steven L.; Hofler, Thomas J.

    1991-12-01

    A new refrigerator which uses resonant high amplitude sound in inert gases to pump heat is described and demonstrated. The phasing of the thermoacoustic cycle is provided by thermal conduction. This 'natural' phasing allows the entire refrigerator to operate with only one moving part (the loudspeaker diaphragm). The thermoacoustic refrigerator has no sliding seals, requires no lubrication, uses only low-tolerance machine parts, and contains no expensive components. Because the compressor moving mass is typically small and the oscillation frequency is high, the small amount of vibration is very easily isolated. This low vibration and lack of sliding seals makes thermoacoustic refrigeration an excellent candidate for food refrigeration and commercial/residential air conditioning applications. The design, fabrication, and performance of the first practical, autonomous thermoacoustic refrigerator, which will be flown on the Space Shuttle (STS-42), are described, and designs for terrestrial applications are presented.

  12. Minimizing quality deteriorations of refrigerated foodstuffs as a side effect of defrosting

    DEFF Research Database (Denmark)

    Cai, Junping; Stoustrup, Jakob

    2008-01-01

    This paper proposes an optimization scheme for traditional refrigeration systems with hysteresis controllers and scheduled defrosts. It aims at minimizing the side effect of defrost cycles on the storage quality of refrigerated foodstuffs in supermarkets. By utilizing the thermal mass of air...... and products inside a display cabinet, this optimization scheme forces the compressor to work harder and cool down more prior to the scheduled defrosts, thus guaranteeing the product temperature after defrost cycles still to be within a controlled safe level....

  13. Influence of special attributes of zeotropic refrigerant mixtures on design and operation of vapour compression refrigeration and heat pump systems

    International Nuclear Information System (INIS)

    Rajapaksha, Leelananda

    2007-01-01

    The use of zeotropic refrigerant mixtures introduces a number of novel issues that affect the established design and operational practices of vapour compression systems used in refrigeration, air conditioning and heat pump applications. Two attributes; composition shift and temperature glide, associated with the phase changing process of zeotropic mixtures are the primary phenomena that bring in these issues. However, relevant researches are uncovering ways how careful system designs and selection of operational parameters allow improving the energy efficiency and the capacity of vapour compression refrigeration systems. Most of these concepts exploit the presence of composition shift and temperature glide. This paper qualitatively discusses how the mixture attributes influence the established heat exchanger design practices, performance and operation of conventional vapour compression systems. How the temperature glide and composition shift can be incorporated to improve the system performance and the efficiency are also discussed

  14. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1997-02-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alterative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on various refrigerants. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.

  15. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1999-01-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilities access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  16. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1996-07-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  17. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1996-11-15

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  18. Food transport refrigeration - Approaches to reduce energy consumption and environmental impacts of road transport

    International Nuclear Information System (INIS)

    Tassou, S.A.; De-Lille, G.; Ge, Y.T.

    2009-01-01

    Food transport refrigeration is a critical link in the food chain not only in terms of maintaining the temperature integrity of the transported products but also its impact on energy consumption and CO 2 emissions. This paper provides a review of (a) current approaches in road food transport refrigeration, (b) estimates of their environmental impacts, and (c) research on the development and application of alternative technologies to vapour compression refrigeration systems that have the potential to reduce the overall energy consumption and environmental impacts. The review and analysis indicate that greenhouse gas emissions from conventional diesel engine driven vapour compression refrigeration systems commonly employed in food transport refrigeration can be as high as 40% of the greenhouse gas emissions from the vehicle's engine. For articulated vehicles over 33 ton, which are responsible for over 80% of refrigerated food transportation in the UK, the reject heat available form the engine is sufficient to drive sorption refrigeration systems and satisfy most of the refrigeration requirements of the vehicle. Other promising technologies that can lead to a reduction in CO 2 emissions are air cycle refrigeration and hybrid systems in which conventional refrigeration technologies are integrated with thermal energy storage. For these systems, however, to effectively compete with diesel driven vapour compression systems, further research and development work is needed to improve their efficiency and reduce their weight

  19. A proof-of-concept implementation of persistence in a hierarchical storage system

    International Nuclear Information System (INIS)

    Grossman, R.; Qin, Xiao; Lifka, D.

    1992-01-01

    The concept of providing transparent access to a collection of files in a mass storage system is a familiar one. The goal of this project was to investigate the feasibility of providing similar access to a collection of persistent, complex objects. We describe an architecture for interfacing a persistent store of complex objects to a hierarchical storage system. Persistent object stores support the uniform creation, storage, and access of complex objects, regardless of their lifetimes. In other words, a mechanism is provided so that persistent objects outlive the processes which create them and can be accessed in a uniform manner by other processes. We validated this architecture by implementing a proof-of-concept system and testing the system on two stores of data. These tests indicate that this architecture supports the creation. storage and access of very large persistent object stores

  20. Effects of irradiation dose and O(2) and CO(2) concentrations in packages on foodborne pathogenic bacteria and quality of ready-to-cook seasoned ground beef product (meatball) during refrigerated storage.

    Science.gov (United States)

    Gunes, Gurbuz; Yilmaz, Neriman; Ozturk, Aylin

    2012-01-01

    Combined effects of gamma irradiation and concentrations of O(2) (0, 5, 21%) and CO(2) (0, 50%) on survival of Escherichia coli O157:H7, Salmonella enteritidis, Listeria monocytogenes, lipid oxidation, and color changes in ready-to-cook seasoned ground beef (meatball) during refrigerated storage were investigated. Ground beef seasoned with mixed spices was packaged in varying O(2) and CO(2) levels and irradiated at 2 and 4 kGy. Irradiation (4 kGy) caused about 6 Log inactivation of the inoculated pathogens. Inactivation of Salmonella was 0.9- and 0.4-Log lower in 0 and 5% O(2), respectively, compared to 21% O(2). Irradiation at 2 and 4 kGy increased thiobarbituric acid reactive substances in meatballs by 0.12 and 0.28 mg malondialdehyde kg(-1), respectively, compared to control. In reduced-O(2) packages, radiation-induced oxidation was lower, and the initial color of an irradiated sample was maintained. Packaging with 0% + 50% CO(2) or 5% O(2) + 50% CO(2) maintained the oxidative and the color quality of irradiated meatballs during 14-day refrigerated storage. MAP with 5%O(2) + 50% CO(2) combined with irradiation up to 4 kGy is suggested for refrigerated meatballs to reduce the foodborne pathogen risk and to maintain the quality.

  1. Effects of Irradiation Dose and O2 and CO2 Concentrations in Packages on Foodborne Pathogenic Bacteria and Quality of Ready-to-Cook Seasoned Ground Beef Product (Meatball) during Refrigerated Storage

    Science.gov (United States)

    Gunes, Gurbuz; Yilmaz, Neriman; Ozturk, Aylin

    2012-01-01

    Combined effects of gamma irradiation and concentrations of O2 (0, 5, 21%) and CO2 (0, 50%) on survival of Escherichia coli O157:H7, Salmonella enteritidis, Listeria monocytogenes, lipid oxidation, and color changes in ready-to-cook seasoned ground beef (meatball) during refrigerated storage were investigated. Ground beef seasoned with mixed spices was packaged in varying O2 and CO2 levels and irradiated at 2 and 4 kGy. Irradiation (4 kGy) caused about 6 Log inactivation of the inoculated pathogens. Inactivation of Salmonella was 0.9- and 0.4-Log lower in 0 and 5% O2, respectively, compared to 21% O2. Irradiation at 2 and 4 kGy increased thiobarbituric acid reactive substances in meatballs by 0.12 and 0.28 mg malondialdehyde kg−1, respectively, compared to control. In reduced-O2 packages, radiation-induced oxidation was lower, and the initial color of an irradiated sample was maintained. Packaging with 0% + 50% CO2 or 5% O2 + 50% CO2 maintained the oxidative and the color quality of irradiated meatballs during 14-day refrigerated storage. MAP with 5%O2 + 50% CO2 combined with irradiation up to 4 kGy is suggested for refrigerated meatballs to reduce the foodborne pathogen risk and to maintain the quality. PMID:22566763

  2. Effects of Irradiation Dose and O2 and CO2 Concentrations in Packages on Foodborne Pathogenic Bacteria and Quality of Ready-to-Cook Seasoned Ground Beef Product (Meatball during Refrigerated Storage

    Directory of Open Access Journals (Sweden)

    Gurbuz Gunes

    2012-01-01

    Full Text Available Combined effects of gamma irradiation and concentrations of O2 (0, 5, 21% and CO2 (0, 50% on survival of Escherichia coli O157:H7, Salmonella enteritidis, Listeria monocytogenes, lipid oxidation, and color changes in ready-to-cook seasoned ground beef (meatball during refrigerated storage were investigated. Ground beef seasoned with mixed spices was packaged in varying O2 and CO2 levels and irradiated at 2 and 4 kGy. Irradiation (4 kGy caused about 6 Log inactivation of the inoculated pathogens. Inactivation of Salmonella was 0.9- and 0.4-Log lower in 0 and 5% O2, respectively, compared to 21% O2. Irradiation at 2 and 4 kGy increased thiobarbituric acid reactive substances in meatballs by 0.12 and 0.28 mg malondialdehyde kg−1, respectively, compared to control. In reduced-O2 packages, radiation-induced oxidation was lower, and the initial color of an irradiated sample was maintained. Packaging with 0% + 50% CO2 or 5% O2 + 50% CO2 maintained the oxidative and the color quality of irradiated meatballs during 14-day refrigerated storage. MAP with 5%O2 + 50% CO2 combined with irradiation up to 4 kGy is suggested for refrigerated meatballs to reduce the foodborne pathogen risk and to maintain the quality.

  3. Concept study for interim storage of research reactor fuel elements in transport and storage casks. Transport and storage licensing procedure for the CASTOR MTR 2 cask. Final report

    International Nuclear Information System (INIS)

    Weiss, M.

    2001-01-01

    As a result of the project, a concept was to be developed for managing spent fuel elements from research reactors on the basis of the interim storage technology existing in Germany, in order to make the transition to direct disposal possible in the long term. This final report describes the studies for the spent fuel management concept as well as the development of a transport and storage cask for spent fuel elements from research reactors. The concept analyses were based on data of the fuel to be disposed of, as well as the handling conditions for casks at the German research reactors. Due to the quite different conditions for handling of casks at the individual reactors, it was necessary to examine different cask concepts as well as special solutions for loading the casks outside of the spent fuel pools. As a result of these analyses, a concept was elaborated on the basis of a newly developed transport and storage cask as well as a mobile fuel transfer system for the reactor stations, at which a direct loading of the cask is not possible, as the optimal variant. The cask necessary for this concept with the designation CASTOR trademark MTR 2 follows in ist design the tried and tested principles of the CASTOR trademark casks for transport and interim storage of spent LWR fuel. With the CASTOR trademark MTR 2, it is possible to transport and to place into long term interim storage various fuel element types, which have been and are currently used in German research reactors. The technical development of the cask has been completed, the documents for the transport license as type B(U)F package design and for obtaining the storage license at the interim storage facility of Ahaus have been prepared, submitted to the licensing authorities and to a large degree already evaluated positively. The transport license of the CASTOR trademark MTR 2 has been issued for the shipment of VKTA-contents and FRM II compact fuel elements. (orig.)

  4. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1996-04-15

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on refrigerants. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates. Citations in this report are divided into the following topics: thermophysical properties; materials compatibility; lubricants and tribology; application data; safety; test and analysis methods; impacts; regulatory actions; substitute refrigerants; identification; absorption and adsorption; research programs; and miscellaneous documents. Information is also presented on ordering instructions for the computerized version.

  5. The estimation of energy efficiency for hybrid refrigeration system

    International Nuclear Information System (INIS)

    Gazda, Wiesław; Kozioł, Joachim

    2013-01-01

    Highlights: ► We present the experimental setup and the model of the hybrid cooling system. ► We examine impact of the operating parameters of the hybrid cooling system on the energy efficiency indicators. ► A comparison of the final and the primary energy use for a combination of the cooling systems is carried out. ► We explain the relationship between the COP and PER values for the analysed cooling systems. -- Abstract: The concept of the air blast-cryogenic freezing method (ABCF) is based on an innovative hybrid refrigeration system with one common cooling space. The hybrid cooling system consists of a vapor compression refrigeration system and a cryogenic refrigeration system. The prototype experimental setup for this method on the laboratory scale is discussed. The application of the results of experimental investigations and the theoretical–empirical model makes it possible to calculate the cooling capacity as well as the final and primary energy use in the hybrid system. The energetic analysis has been carried out for the operating modes of the refrigerating systems for the required temperatures inside the cooling chamber of −5 °C, −10 °C and −15 °C. For the estimation of the energy efficiency the coefficient of performance COP and the primary energy ratio PER for the hybrid refrigeration system are proposed. A comparison of these coefficients for the vapor compression refrigeration and the cryogenic refrigeration system has also been presented.

  6. Archival storage solutions for PACS

    Science.gov (United States)

    Chunn, Timothy

    1997-05-01

    While they are many, one of the inhibitors to the wide spread diffusion of PACS systems has been robust, cost effective digital archive storage solutions. Moreover, an automated Nearline solution is key to a central, sharable data repository, enabling many applications such as PACS, telemedicine and teleradiology, and information warehousing and data mining for research such as patient outcome analysis. Selecting the right solution depends on a number of factors: capacity requirements, write and retrieval performance requirements, scaleability in capacity and performance, configuration architecture and flexibility, subsystem availability and reliability, security requirements, system cost, achievable benefits and cost savings, investment protection, strategic fit and more.This paper addresses many of these issues. It compares and positions optical disk and magnetic tape technologies, which are the predominant archive mediums today. Price and performance comparisons will be made at different archive capacities, plus the effect of file size on storage system throughput will be analyzed. The concept of automated migration of images from high performance, high cost storage devices to high capacity, low cost storage devices will be introduced as a viable way to minimize overall storage costs for an archive. The concept of access density will also be introduced and applied to the selection of the most cost effective archive solution.

  7. Atmospheric Mining in the Outer Solar System: Resource Capturing, Storage, and Utilization

    Science.gov (United States)

    Palaszewski, Bryan

    2014-01-01

    Atmospheric mining in the outer solar system has been investigated as a means of fuel production for high energy propulsion and power. Fusion fuels such as helium 3 and hydrogen can be wrested from the atmospheres of Uranus and Neptune and either returned to Earth or used in-situ for energy production. Helium 3 and hydrogen (deuterium, etc.) were the primary gases of interest with hydrogen being the primary propellant for nuclear thermal solid core and gas core rocket-based atmospheric flight. A series of analyses were undertaken to investigate resource capturing aspects of atmospheric mining in the outer solar system. This included the gas capturing rate for hydrogen helium 4 and helium 3, storage options, and different methods of direct use of the captured gases. Additional supporting analyses were conducted to illuminate vehicle sizing and orbital transportation issues.

  8. Oxidative stability of refrigerated fish pates containing loquat seed extract

    Directory of Open Access Journals (Sweden)

    Jaqueline Piccolo

    2014-09-01

    Full Text Available This study investigated the effects of hydroethanolic E. japonica seed extracts (EJSE as inhibitors of lipid and protein oxidation on fish pates subjected to refrigerated storage. Five fish pate formulations were developed. These formulations included two control pates (water-control and ascorbic acid-control and three pates with added EJSE (0.1, 0.2 and 0.4g of seed 100g-1 product, equivalent to 3.4, 6.8 or 13.6mg phenolic compounds kg-1 product, which were then stored under refrigeration for 35 days. Conjugated dienes (CD and peroxide (PV values increased along with the storage time; however, these values decreased and were similar among all samples at the end of 35 days of analysis (P<0.05. However, the thiobarbituric acid reactive substances levels (TBARS did not change along the storage and were not affected by the EJSE. Additionally, there was a linear increase in the protein carbonyl content of fish pates over the storage period (P<0.05, but no effect of EJSE on protein oxidation. The results show that, at the concentrations evaluated, hydroethanolic E. japonica seed extract was unable to inhibit or reduce lipid and protein oxidation in fish pates, but the observed phenolic content emphasizes the need for further studies on the wastes of this fruit.

  9. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1998-08-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufactures and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on many refrigerants including propane, ammonia, water, carbon dioxide, propylene, ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.

  10. Keeping carrots quality during storage by irradiation

    International Nuclear Information System (INIS)

    El-Nashaby, F.M.; Hafez, S.A.

    2000-01-01

    Fresh carrots were gamma irradiated at 0, 0.1, 0.2, 0.5 and 1.0 KGy doses using cobalt-60 source. A portion of the irradiated carrots was stored at ambient temperature (20-25 degree C) and the rest was packed in polyethylene bags and stored in refrigerator temperature (5± 1 degree C). The results indicated that the sprouting of carrots were completely inhibited by radiation dose of 0.2 KGy either at ambient temperature or cold storage, while the non-irradiated samples started to sprout after 2 and 4 weeks of storage at ambient temperature and cold storage respectively. Furthermore, samples treated with gamma rays showed lower values of weight loss compared to the untreated ones during storage. Concerning storage temperature, it was found that the rate of weight loss during storage was higher at ambient temperature than in refrigerator. Micro-organisms were greatly affected by gamma rays, their counts were found to be decreased by increasing irradiation dose as compared with the control sample. Moreover, during storage period, refrigerated samples showed lower bacterial and molds counts than samples stored at ambient temperature. On the other hand, it was also observed that irradiated samples at the higher dose i.e. 1.0 KGy stored either at ambient temperature or in refrigerator showed higher bacterial and molds counts than unirradiated ones. The lowest dose (0.1 KGy) had no effect on carotene and sugars contents of carrots while increasing the dose above 0.2 KGy led to gradual decrease in carotene contents and gradual increase in total soluble sugars contents of the samples with increasing the irradiation dose compared with the nonirradiated ones. The results proved that gamma irradiation dose of 0.2 Gy was effective for sprout inhibition of carrots and increase their shelf-life to 10 weeks at ambient temperature without adverse effects on carotene and sugars contents of treated carrots

  11. Impacts of Irradiation Sources on Quality Attributes of Low-salt Sausage during Refrigerated Storage

    Science.gov (United States)

    Kim, Hyun-Wook; Choi, Yun-Sang

    2017-01-01

    This study was performed to investigate the impacts of irradiation sources on quality attributes of low-salt sausage during refrigerated storage. Control sausage was prepared with 1.5% sodium chloride (NaCl), whereas low-salt sausage was formulated with 0.75% NaCl (a 50% reduction; L-control). Sausage samples were vacuum-packaged, and low-sausages were irradiated with gamma-ray, electron-beam and X-ray at 5 kGy, respectively. The samples were stored at 4°C for 28 d to determine changes in quality attributes. The pH of low-salt sausages was unaffected by irradiation at 5 kGy (p>0.05). Higher redness values were found at irradiated low-salt sausages compared to control (psausage were higher than those of low-salt sausages (psausage treatments. The overall sensory acceptability score of irradiated/low-salt sausages were lower than L-control due to decreased scores for cooked meat flavor but increased radiolytic off-flavor (psausages were higher than control and L-control (psausages (psausages, and suggest that further studies should be necessary to reducing radiolytic off-flavor of irradiated/low-salt sausages. PMID:29147093

  12. Quality loss assessment in fish-based ready-to-eat foods during refrigerated storage

    Directory of Open Access Journals (Sweden)

    Pourashouri, P.

    2013-03-01

    Full Text Available The present research addresses the quality loss in two different ready-to-eat (RTE seafoods. With this aim, chemical and microbiological parameters were measured in tuna lasagne (TL and hake roe foods which were refrigerated (4°C for up to 35 and 71 days, respectively. Both foods showed a significant lipid oxidation (peroxide and interaction compound formation development with storage time, which was especially marked in the case of the TL product, which also underwent an important lipid hydrolysis development. Both RTE products showed a low microbial development, no matter how much time had elapsed since the expiration dates; thus, low total viable count scores and volatile amine formation were attained while the presence of pathogen microorganisms was not detected. In view of the current increasing consumer demand for high quality refrigerated foods, the assessment of lipid damage related to nutritional and sensory values is recommended when fish-based RTE products are encountered.

    Se estudió la pérdida de calidad de dos productos marinos elaborados (lasaña de atún, TL; huevas de merluza conservados en refrigeración (4 °C durante 35 y 71 días, respectivamente. Ambos alimentos mostraron un desarrollo importante de la oxidación lipídica (formación de peróxidos y compuestos de interacción durante el periodo de conservación, siendo mayor en el caso de TL; asimismo, el producto TL experimentó un importante desarrollo de hidrólisis lipídica. Sin embargo, ambos alimentos experimentaron un desarrollo bajo en microorganismos mesófilos y aminas volátiles; por otra parte, no maniferstaron presencia de microorganismos patógenos a lo largo del periodo de conservación, a pesar de sobrepasar el tiempo de caducidad. De acuerdo con la creciente demanda de nuevas preparaciones de alimentos refrigerados de calidad alta, se recomienda el estudio de las alteraciones lipídicas en elaboraciones basadas en alimentos de origen marino

  13. Some comments about the comparison between a conventional and a solar powered absorption refrigeration system

    International Nuclear Information System (INIS)

    Corbella, O.D.; Garibotti, C.R.

    1983-08-01

    Two statements about the performance of solar refrigeration systems are discussed. First, concepts of efficiency and coefficient of performance are studied. Second, the influence of inflation and rise of fuel prices are considered, in relation to the comparison between solar and conventional refrigeration systems. (author)

  14. Evaluation of concepts for monitored retrievable storage of spent nuclear fuel and high-level radioactive waste

    International Nuclear Information System (INIS)

    Triplett, M.B.; Smith, R.I.

    1984-04-01

    The primary mission selected by DOE for the monitored retrieval storage (MRS) system is to provide an alternative means of storage in the event that the repository program is delayed. The MRS concepts considered were the eight concepts included in the MRS Research and Development Report to Congress (DOE 1983). These concepts are: metal cask (stationary and transportable); concrete cask (sealed storage cask); concrete cask-in-trench; field drywell; tunnel drywell; open cycle vault; closed cycle vault; and tunnel rack vault. Conceptual design analyses were performed for the candidate concepts using a common set of design requirements specified in consideration of the MRS mission

  15. Bio-mass stimulated absorption refrigerator for food storage in Papua New Guinea

    Energy Technology Data Exchange (ETDEWEB)

    Uppal, A.H.; Komuna, K.K. (University of Technology, Papua (New Guinea). Dept. of Mechanical Engineering)

    1992-01-01

    A medium capacity (140 litre) water-ammonia absorption refrigerator, thermally stimulated by a charcoal-stove is being developed to store food in remote locations and island communities of Papua New Guinea. The paper describes a prototype charcoal or biomass-stove thermal refrigerator in which the absorption cycle and thermo-syphonic cycle of a heating liquid has been coupled in a novel and straight forward approach. The system consisted of a heat-exchanger, in the form of a jacket surrounding the generator tube of a water-ammonia absorption cycle refrigerator, and was connected in a close-pipe work loop to a heat exchanger placed in a charcoal-stove. A heat-transfer oil flowed due to thermo-syphonic forces between the heat exchanger and the jacket. According to initial tests it took 4 hours for the system to warm up, and took another 7 hours for water in the freezer cabinet to approach 0{sup o}C from an initial 25{sup o}C. The cooling capacity of the evaporator was roughly 70% of the cooling capacity of the original system with electric heating. For a twelve hour test the stove consumed 2.5 kg of charcoal with an air port opening between 3 to 5 millimeters. Preliminary estimates indicate that the described prototype absorption unit stimulated by the wood/coconut husk stove (rather than electricity/kerosene), when manufactured commercially will cost less than US 1500 dollars at 1991 prices. (Author).

  16. Effect of curing ingredients and vacuum packaging on the physicochemical and storage quality of ready-to-eat Vawksa rep (smoked pork product during refrigerated storage

    Directory of Open Access Journals (Sweden)

    Deepshikha Deuri

    2016-06-01

    Full Text Available Aim: The present study was conducted for the development of ready-to-eat Vawksa rep (smoked pork product and to study the synergistic effect of curing ingredients and vacuum packaging on the physico-chemical and storage quality during refrigerated storage at (4°C±1°C for 15 days. Materials and Methods: Four different batches of Vawksa rep samples were prepared, i.e., T-1 (uncured, first cooked at 121°C for 15 min, and then smoked at 120°C for 30 min, T-2 (uncured, cooked, and smoked simultaneously at 120°C for 45 min, T-3 (cured, first cooked at 121°C for 15 min, and then smoked at 120°C for 30 min, and T-4 (cured, cooked, and smoked simultaneously at 120°C for 45 min. Results: Cooking yield was significantly higher (p<0.05 for the T-4. The pH of T-3 and T-4 samples was significantly higher (p<0.05 on day 15. The tyrosine value of all the samples increased significantly (p<0.05 among the different days of analysis. Thiobarbituric acid value was significantly (p<0.05 lower in T-3 sample both at the beginning and at the end of storage period. In microbiological profile, total plate count was lower in T-3 and T-4 than T-1 and T-2. However, Escherichia coli count was negative for T-3 and T-4 samples throughout the storage period. Among sensory attributes, T-3 and T-4 samples registered superior scores for color, flavor, texture, juiciness, and overall acceptability. Conclusion: Furthermore, Vawksa rep (smoked pork product could be prepared easily with little technology up-gradation and with a negligible escalation of production cost.

  17. Latent heat coldness storage; Stockage du froid par chaleur latente

    Energy Technology Data Exchange (ETDEWEB)

    Dumas, J.P. [Pau Univ., Lab. de Thermodynamique et Energetique, LTE, 64 (France)

    2002-07-01

    This article presents the advantages of latent heat storage systems which use the solid-liquid phase transformation of a pure substance or of a solution. The three main methods of latent heat storage of coldness are presented: ice boxes, encapsulated nodules, and ice flows: 1 - definition of the thermal energy storage (sensible heat, latent heat, thermochemical storage); 2 - advantages and drawbacks of latent heat storage; 3 - choice criteria for a phase-change material; 4 - phenomenological aspect of liquid-solid transformations (phase equilibrium, crystallisation and surfusion); 5 - different latent heat storage processes (ice boxes, encapsulated nodules, two-phase refrigerating fluids); 6 - ice boxes (internal and external melting, loop, air injection, measurement of ice thickness); 7 - encapsulated nodules (nodules, tank, drainage, advantage and drawbacks, charge and discharge); 8 - two-phase refrigerating fluids (composition, ice fabrication, flow circulation, flow storage, exchangers). (J.S.)

  18. The medicines refrigerator and the importance of the cold chain in the safe storage of medicines.

    Science.gov (United States)

    Hatchett, Richard

    2017-10-04

    The medicines refrigerator is a common piece of equipment found in clinical areas. It is used to ensure specific medicines are safely stored within a narrow temperature range in line with manufacturers' instructions; this is usually between +2˚C and +8˚C, and ideally +5˚C. Drugs stored in the medicines refrigerator include: vaccines; insulin; chemotherapy drugs; topical preparations, such as some types of eye drops; and other treatments such as glucagon, which is used to manage severe hypoglycaemia. This article reviews the function of the medicines refrigerator and the checks required by healthcare practitioners to ensure that medicines remain safely stored and their effectiveness is maintained. It also outlines the medicines refrigeration procedure known as the 'cold chain', which includes the use of cold boxes or vaccine carriers to maintain the required temperature of medicines during transport from the manufacturer to user, or between healthcare departments. ©2012 RCN Publishing Company Ltd. All rights reserved. Not to be copied, transmitted or recorded in any way, in whole or part, without prior permission of the publishers.

  19. Commissioning of the Cryogenic Plant for the Cryogenic Storage Ring (CSR) at Heidelberg

    CERN Document Server

    von Hahn, R; Grieser, M; Haberstroh, C; Kaiser, D; Lange, M; Laux, F; Menk, S; Orlov, D A; Repnow, R; Sieber, T; Quack, H; Varju, J; Wolf A

    2009-01-01

    At the Max-Planck-Institute for Nuclear Physics in Heidelberg a next generation electrostatic storage ring for low velocity atomic and molecular ion beams is under construction. In contrast to existing electrostatic storage rings, the Cryogenic Storage Ring CSR will be cooled down to temperatures below 2 K. Thus acting as a large cryopump it will provide long storage times and, in addition, open a new field of quantum state controlled molecular physics due to a low heat radiation background from space-like environment. A concept for cooling the storage ring has been developed and is presently tested by means of a linear trap as a prototype with a length of 1/10 of the planned ring. A commercial refrigerator with 21 W at 2 K has been successfully commissioned and was connected to the prototype. This paper presents the status of the cryogenic plant after the commissioning and one year of operation.

  20. Evaluation of synergistic effect in vacuum pack, refrigeration and irradiated treatments of minimally processed cassava

    International Nuclear Information System (INIS)

    Pedroso, Bianca Maria

    2005-01-01

    Cassava is cultivated almost all over the world and it is considered one of the most important nutritious sources of calories in the human diet. Cassava is a viable food against starvation in several poor areas of the world because it is an extremely resistant culture and may reach satisfactory economical yield. We utilized vacuum packed industrialized cassava irradiated with 0,1 kGy, 3kGy and 5kGy and stored under refrigeration for 1, 21, 30 and 50 days. Our objective was to analyse the synergistic effect of vacuum packing, irradiation and refrigeration on the preservation of minimally processed cassava. The samples were analyzed for pH, acidity, weight, humidity, texture and color. The irradiation did not affect the chemical characteristics of the cassava. Neither the pH nor the acidity, the most relevant variables to verify deterioration in cassava, presented significant alterations during the period of storage. Comparing the irradiated treatments, the dose of 1kGy and 3kGy affected the physic-chemical characteristics of the cassava the least during the period of storage and refrigeration for 50 days; the doses of 1kGy,3kGy and 5kGy scored the highest rates the sensorial analysis during the period of storage for 21 days. (author)

  1. Performance evaluation of solar photovoltaic panel driven refrigeration system

    Science.gov (United States)

    Rajoria, C. S.; Singh, Dharmendra; Gupta, Pankaj Kumar

    2018-03-01

    The solar photovoltaic (PV) panel driven refrigeration system employs solar PV panel and play a vital role when combined with storage batteries. The variation in performance of solar PV panel driven refrigeration system has been experimentally investigated in this paper. The change in battery voltage is analyzed with respect to panel size. Different series and parallel combinations have been applied on four solar PV panels of 35W each to get 24V. With the above combination a current in the range of 3-5 ampere has been obtained depending upon the solar intensity. A refrigerator of 110 W and 50 liters is used in the present investigation which requires 0.80 ampere AC at 230 V. The required current and voltage has been obtained from an inverter which draws about 7 ampere DC from the battery bank at 24V. The compressor of the refrigerator consumed 110W which required a PV panel size of 176 W approximately. It is important to note that the compressor consumed about 300W for first 50 milliseconds, 130 W for next five seconds and gradually comes to 110 W in 65 seconds. Thus panel size should be such that it may compensate for the initial load requirement.

  2. Concepts for Waste Retrieval and Alternate Storage of Radioactive Waste

    International Nuclear Information System (INIS)

    F.J. Bierich

    2005-01-01

    The primary purpose of this technical report is to present concepts for retrieval operations, equipment to be used, scenarios under which waste retrieval operations will take place, methods for responding to potential retrieval problems, and compliance with the preclosure performance objectives of 10 CFR 63.111(a) and (b) [DIRS 156605] during the retrieval of waste packages from the subsurface repository. If a decision for retrieval is made for any or all of the waste, the waste to be retrieved would be dispositioned in accordance with the regulations applicable at the time. The secondary purpose is to present concepts for the design, construction, and operation of an alternate storage facility. The alternate storage facility would temporarily house the retrieved waste until final disposition is established. The concept presented is consistent with current practices and regulations for the protection of public health and safety and the environment, it demonstrates the feasibility of such a facility, if required, and it is based on the consideration for keeping radiation exposure as low as is reasonably achievable (ALARA)

  3. Model Predictive Control of Hybrid Thermal Energy Systems in Transport Refrigeration

    DEFF Research Database (Denmark)

    Shafiei, Seyed Ehsan; Alleyne, Andrew

    2015-01-01

    A predictive control scheme is designed to control a transport refrigeration system, such as a delivery truck, that includes a vapor compression cycle configured in parallel with a thermal energy storage (TES) unit. A novel approach to TES utilization is introduced and is based on the current...

  4. Portable refrigerant charge meter and method for determining the actual refrigerant charge in HVAC systems

    Science.gov (United States)

    Gao, Zhiming; Abdelaziz, Omar; LaClair, Tim L.

    2017-08-08

    A refrigerant charge meter and a method for determining the actual refrigerant charge in HVAC systems are described. The meter includes means for determining an optimum refrigerant charge from system subcooling and system component parameters. The meter also includes means for determining the ratio of the actual refrigerant charge to the optimum refrigerant charge. Finally, the meter includes means for determining the actual refrigerant charge from the optimum refrigerant charge and the ratio of the actual refrigerant charge to the optimum refrigerant charge.

  5. Application of Cascade Refrigeration System with Mixing Refrigerant in Cold Air Cutting

    Science.gov (United States)

    Yang, Y.; Tong, M. W.; Yang, G.; Wang, X. P.

    In the mechanical cutting process, the replacement of traditional cutting solution with cold air can avoid the pollution of environment. In order to high efficient the refrigerating device and flexible adjust the temperature of cold air, it is necessary to use cascade refrigeration system to supply cool quantity for the compressed air. The introduction of a two-component non-azeotropic mixing refrigerant into the cryogenic part of the cascade system, can effectively solve the problems of the system working at too high pressure and the volume expanding of refrigerant in case of the cascade refrigeration sets closed down. However, the filling ratio of mixing refrigerants impact on the relationships among the closing down pressure, refrigerating output and refrigerating efficiency. On the basis of computing and experiment, the optimal mixing ratio of refrigerant R22/R13 and a low temperature of -60° were obtained in this study. A cold air injecting device possessing high efficiency in energy saving has also been designed and manufactured. The cold air, generated from this cascade system and employed in a cutting process, takes good comprehensive effects on machining and cutting.

  6. Review of magnetic refrigeration system as alternative to conventional refrigeration system

    Science.gov (United States)

    Mezaal, N. A.; Osintsev, K. V.; Zhirgalova, T. B.

    2017-10-01

    The refrigeration system is one of the most important systems in industry. Developers are constantly seeking for how to avoid the damage to the environment. Magnetic refrigeration is an emerging, environment-friendly technology based on a magnetic solid that acts as a refrigerant by magneto-caloric effect (MCE). In the case of ferromagnetic materials, MCE warms as the magnetic moments of the atom are aligned by the application of a magnetic field. There are two types of magnetic phase changes that may occur at the Curie point: first order magnetic transition (FOMT) and second order magnetic transition (SOMT). The reference cycle for magnetic refrigeration is AMR (Active Magnetic Regenerative cycle), where the magnetic material matrix works both as a refrigerating medium and as a heat regenerating medium, while the fluid flowing in the porous matrix works as a heat transfer medium. Regeneration can be accomplished by blowing a heat transfer fluid in a reciprocating fashion through the regenerator made of magnetocaloric material that is alternately magnetized and demagnetized. Many magnetic refrigeration prototypes with different designs and software models have been built in different parts of the world. In this paper, the authors try to shed light on the magnetic refrigeration and show its effectiveness compared with conventional refrigeration methods.

  7. Storage of Human Breast Milk

    Directory of Open Access Journals (Sweden)

    Gamze Can

    2007-10-01

    Full Text Available Storage of human breast milk by freezing or refrigeration of milk has been recommended especially at some social circumstances of most mothers who are regularly separated from their infants because of work. The greatest fear that has hindered the prospects of in - vitro storage of breast milk for any considerable period of time is the possibility of bacterial contamination and growth of infectious pathogens in the stored milk, there by rendering them unsafe for human consumption. The storage container can influence the cell content of milk, as the cells adhere to the walls of a glass container but not to polyethylene or polypropylene containers. Bacteriological examination of refrigerated milks has proven their safety for human consumption for even up to 72 h. For a storage over longer periods up to 1 month, freezing at - 20 0C could be recommended, but the most preferred method, especially for longer storage would be fresh freezing at - 70 0C, if affordable or available. The nutrient value of human milk is essentially unchanged, but the immunological properties are reduced by various storage techniques. Boiling and microwave radiation have not been recommended. [TAF Prev Med Bull 2007; 6(5.000: 375-379

  8. Effects of hysteresis and Brayton cycle constraints on magnetocaloric refrigerant performance

    Science.gov (United States)

    Brown, T. D.; Buffington, T.; Shamberger, P. J.

    2018-05-01

    Despite promising proofs of concept, system-level implementation of magnetic refrigeration has been critically limited by history-dependent refrigerant losses that interact with governing thermodynamic cycles to adversely impact refrigeration performance. Future development demands a more detailed understanding of how hysteresis limits performance, and of how different types of cycles can mitigate these limitations, but without the extreme cost of experimental realization. Here, the utility of Brayton cycles for magnetic refrigeration is investigated via direct simulation, using a combined thermodynamic-hysteresis modeling framework to compute the path-dependent magnetization and entropy of a model alloy for a variety of feasible Brayton cycles between 0-1.5 T and 0-5 T. By simultaneously varying the model alloy's hysteresis properties and applying extensions of the thermodynamic laws to non-equilibrium systems, heat transfers and efficiencies are quantified throughout the space of hystereses and Brayton cycles and then compared with a previous investigation using Ericsson cycles. It is found that (1) hysteresis losses remain a critical obstacle to magnetic refrigeration implementation, with efficiencies >80% in the model system requiring hysteresis refrigerant transformation temperatures at the relevant fields; (3) for a given hysteresis and field constraint, Brayton and Ericsson-type cycles generate similar efficiencies; for a given temperature span, Ericsson cycles lift more heat per cycle, with the difference decreasing with the refrigerant heat capacity outside the phase transformation region.

  9. 2013 German refrigeration and air conditioning meeting. Proceedings

    International Nuclear Information System (INIS)

    2013-01-01

    These proceedings cover the following main topics: cryoengineering - superconduction / energy storage; cryoapplications in biology and medicine; metrology; adsorption processes; condensation/evaporation; working fluids / simulation; ice production; plants and compressors; expansion and ejectors or recooling; use of cooling (passenger car air conditioning, supermarket); refrigerants; plant efficiency; emissions and legislation; air conditioning and use of heat pumps; air quality and control; building technology and block-type thermal power stations. [de

  10. Effects of chitosan on the shelf life of marinated sardine (Sardina pilchardus fillets during refrigerated storage

    Directory of Open Access Journals (Sweden)

    Aygül Küçükgülmez

    2012-07-01

    Full Text Available This study was carried out to evaluate the effect of chitosan on chemical, colour, sensory and microbial changes of marinated sardine (Sardina pilchardus fillets. Marination solution consisted of 10% sodium chloride + 1% chitosan (dissolved in 3% acetic acid for the chitosan group, and 10% sodium chloride + 3% acetic acid solution for the control group. After the marination process, sardine fillets were packed and stored at 4ºC for 60 days. Thiobarbituric acid (TBA values were found to be lower in the chitosan group than the control group (PL*, a*, or b* values of marinated sardine fillets. According to sensory analysis, shelf life of the chitosan group was found to be ten days longer than that of the control group. Total bacteria count of two marinated groups was found to be less than 1 log CFU/g. This study concluded that sardine marination with the addition of chitosan can delay undesirable chemical changes, retard lipid oxidation, improve sensory attributes and extend the shelf life of the product during refrigerated storage.

  11. Preparatory mining and geotechnical work for safe closure of the Asse mine

    International Nuclear Information System (INIS)

    Schmidt, M.W.; Schauermann, V.; Kappei, G.

    2002-01-01

    After the GSF Research Centre for Environment and Health discontinued its own research into the safe ultimate storage of waste hazardous to the environment in deep geological formations and the work of the Institute for Deep Storage was likewise suspended there is no longer any need to continue operation of the Asse mine for research purposes. Hence the closure of the mine is being prepared on the basis of the Federal Mining Act. The GSF accordingly has to submit a final operating plan, with which a comprehensive safety report containing inter alia proof of the long-time safety should be enclosed. The proof should be furnished according to the specific location and takes into account the geological, hydrogeological, geochemical, geotechnical, mining-related conditions and the radionuclide inventory in the Asse mine. (orig.) [de

  12. Application of Best Industry Practices to the Design of Commercial Refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-06-30

    The substantial efficiency improvements which have been realized in residential refrigerators over the last twenty years due to implementation of the National Appliance Energy Conservation Act and changing consumer reactions to energy savings give an indication of the potential for improvement in the commercial sector, where few such efficiency improvements have been made to date. The purchase decision for commercial refrigerators is still focused primarily on first cost and product performance issues such as maximizing storage capacity, quick pulldown, durability, and reliability. The project applied techniques used extensively to reduce energy use in residential refrigeration to a commercial reach-in refrigerator. The results will also be applicable to other commercial refrigeration equipment, such as refrigerated vending machines, reach-in freezers, beverage merchandisers, etc. The project described in this paper was a collaboration involving the Appliance and Building Technology Sector of TIAX, the Delfield Company, and the U. S. Department of Energy's Office of Building Technologies. Funding was provided by DOE through Cooperative Agreement No. DE-FC26-00NT41000. The program plan and schedule were structured to assure successful integration of the TIAX work on development of efficient design concepts into Delfield's simultaneous development of the Vantage product line. The energy-saving design options evaluated as part of the development included brushless DC and PSC fan motors, high-efficiency compressors, variable-speed compressor technology, cabinet thermal improvement (particularly in the face frame area), increased insulation thickness, a trap for the condensate line, improved insulation, reduced-wattage antisweat heaters, non-electric antisweat heating, off-cycle defrost termination, rifled heat exchanger tubing, and system optimization (selection of heat exchangers, fans, and subcooling, superheat, and suction temperatures for efficient

  13. Storage of HLW in engineered structures: air-cooled and water-cooled concepts

    International Nuclear Information System (INIS)

    Ahner, S.; Dekais, J.J.; Puttke, B.; Staner, P.

    1981-01-01

    A comparative study on an air-cooled and a water-cooled intermediate storage of vitrified, highly radioactive waste (HLW) in overground installations has been performed by Nukem and Belgonucleaire respectively. In the air-cooled storage concept the decay heat from the storage area will be removed using natural convection. In the water-cooled storage concept the decay heat is carried off by a primary and secondary forced-cooling system with redundant and diverse devices. The safety study carried out by Nukem used a fault tree method. It shows that the reliability of the designed water-cooled system is very high and comparable to the inherent, safe, air-cooled system. The impact for both concepts on the environment is determined by the release route, but even during accident conditions the release is far below permissible limits. The economic analysis carried out by Belgonucleaire shows that the construction costs for both systems do not differ very much, but the operation and maintenance costs for the water-cooled facility are higher than for the air cooled facility. The result of the safety and economic analysis and the discussions with the members of the working group have shown some possible significant modifications for both systems, which are included in this report. The whole study has been carried out using certain national criteria which, in certain Member States at least, would lead to a higher standard of safety than can be justified on any social, political or economic grounds

  14. Cryogenic forced convection refrigerating system

    International Nuclear Information System (INIS)

    Klee, D.J.

    1988-01-01

    This patent describes the method of refrigerating products by contact with a refrigerating gas which comprises introducing product into a refrigeration zone, contacting the product with the refrigerating gas for a sufficient time to refrigerate it to the appropriate extent and removing the refrigerated product. The improvement for producing the refrigeration gas from a liquid cryogen such that essentially all of the liquid cryogen is fully vaporized before contacting the product comprises: (a) introducing the liquid cryogen, selected from the group consisting of liquid air and liquid nitrogen, at elevated pressure into an ejector as the motive fluid to accelerate a portion of a warm refrigerating gas through the ejector while mixing the cryogen and gas to effect complete vaporization of the liquid cryogen and substantial cooling of the portion of the refrigerating gas resulting in a cold discharge gas which is above the liquefaction temperature of the cryogen; (b) introducing the cold discharge gas into a forced circulation pathway of refrigerating gas and producing a cold refrigerating gas which contacts and refrigerates product and is then at least partially recirculated; (c) sensing the temperature of the refrigerating gas in the forced circulation pathway and controlling the introduction of liquid cryogen with regard to the sensed temperature to maintain the temperature of the discharge gas above the liquefacton temperature of the cryogen utilized

  15. Proceedings of the 13. U.S./North American mine ventilation symposium

    International Nuclear Information System (INIS)

    Hardcastle, S.; McKinnon, D.L.

    2010-01-01

    This biannual symposium has become a major international forum for presenting technical papers in the field of underground mine ventilation. Participants included members of industry, academia and government organizations. The presentations dealt with underground coal and metal mining issues, including fire prevention, air quality control, heat and refrigeration and innovations in fan technology. The papers reflected the issues that underground mine ventilation professionals are currently facing to ensure the health and safety of miners. The sessions 7 were entitled: air quality; metal mine ventilation; coal mine ventilation; heat issues; mine fires; ventilation modeling; and fan technology. All 72 presentations featured at this conference have been catalogued separately for inclusion in this database. refs., tabs., figs.

  16. IEA SHC Task 38 'Solar air-conditioning and refrigeration'. Danish participation 2007-2010. Appendix; IEA SHC Task 38 'Solar air-conditioning and refrigeration'. Dansk deltagelse 2007-2010. Bilag

    Energy Technology Data Exchange (ETDEWEB)

    Ellehauge, K [Ellehauge og Kildemoes, Aarhus (Denmark); Muenster, E [PlanEnergi, Skoerping (Denmark); Reinholdt, L [Teknologisk Institut, Aarhus (Denmark); Munds, S [AC-Sun Aps, Horsens (Denmark)

    2011-03-15

    IEA SHC Task 38 'Solar Air-Conditioning and Refrigeration' ran from October 2006 to December 2010. Denmark was represented in the task from January 2007 to December 2010. The aim of the task was to encourage use of solar powered refrigeration and air conditioning systems in particular at residential, commercial and industrial sectors. Furthermore, the aim was to contribute to new research and development activities on new systems and concepts. The appendix contains the publications prepared by the Danish project group.(LN)

  17. Flow cytometric evaluation of antibiotic effects on viability and mitochondrial function of refrigerated spermatozoa of Nile tilapia

    Science.gov (United States)

    Segovia, M.; Jenkins, J.A.; Paniagua-Chavez, C.; Tiersch, T.R.

    2000-01-01

    Improved techniques for storage and evaluation of fish sperm would enhance breeding programs around the world. The goal of this study was to test the effect of antibiotics on refrigerated sperm from Nile tilapia (Oreochromis niloticus) by use of flow cytometry with 2 dual-staining protocols for objective assessment of sperm quality. Concentrations of 1 x 109 sperm/mL were suspended in Ringer's buffer at 318 mOsmol/kg (pH 8.0). The fluorescent stains Sybr 14 (10 ??M), propidium iodide (2.4 mM), and rhodamine 123 (0.13 ??M) were used to assess cell viability and mitochondrial function. Three concentrations of ampicillin, gentamicin, and an antibiotic/antimycotic solution were added to fresh spermatozoa. Motility estimates and flow cytometry measurements were made daily during 7 d of refrigerated storage (4 ??C). The highest concentrations of gentamicin and antibiotic/antimycotic and all 3 concentrations of ampicillin significantly reduced sperm viability. The highest of each of the 3 antibiotic concentrations significantly reduced mitochondrial function. This study demonstrates that objective sperm quality assessments can be made using flow cytometry and that addition of antibiotics at appropriate concentrations can lengthen refrigerated storage time for tilapia spermatozoa. With minor modifications, these protocols can be adapted for use with sperm from other species and with other tissue types.

  18. Relationship between composition of mixture charged and that in circulation in an auto refrigerant cascade and a J-T refrigerator operating in liquid refrigerant supply mode

    Science.gov (United States)

    Sreenivas, Bura; Nayak, H. Gurudath; Venkatarathnam, G.

    2017-01-01

    The composition of the refrigerant mixture in circulation during steady state operation of J-T and allied refrigerators is not the same as that charged due to liquid hold up in the heat exchangers and phase separators, as well as the differential solubility of different refrigerant components in the compressor lubricating oil. The performance of refrigerators/liquefiers operating on mixed refrigerant cycles is dependent on the mixture composition. It is therefore important to charge the right mixture that results in an optimum composition in circulation during steady state operation. The relationship between the charged and circulating composition has been experimentally studied in a J-T refrigerator operating in the liquid refrigerant supply (LRS) mode and an auto refrigerant cascade refrigerator (with a phase separator) operating in the gas refrigerant supply (GRS) mode. The results of the study are presented in this work. The results show that the method presented earlier for J-T refrigerators operating in GRS mode is also applicable in the case of refrigerators studied in this work.

  19. Flammable refrigerants

    NARCIS (Netherlands)

    Gerwen, R.J.M. van; Verwoerd, M.; Oostendorp, P.A.

    1999-01-01

    Hydrocarbons are promising alternatives for CFC, HCFC and HFC refrigerants. Due to their flammable nature, safety aspects have to be considered carefully. The world-wide situation concerning acceptability and practical application of flammable refrigerants is becoming more and more complex and

  20. Performance of refrigerating machineries with new refrigerants; Performance des machines frigorifiques avec les nouveaux refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Bailly, A; Jurkowski, R [CIAT, 01 - Culoz (France)

    1998-12-31

    This paper reports on a comparative study of the thermal performances of different refrigerants like R-22, R-134a, R-404A and R-407C when used as possible substitutes for the HCFC22 refrigerant in a given refrigerating machinery equipped with compact high performance plate exchangers. Thermal performances are compared in identical operating conditions. The behaviour of the two-phase exchange coefficient is analyzed with respect to the different parameters. The composition of the mixture after one year of operation has been analyzed too and the influence of oil on the performances is studied. (J.S.)

  1. Performance of refrigerating machineries with new refrigerants; Performance des machines frigorifiques avec les nouveaux refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Bailly, A.; Jurkowski, R. [CIAT, 01 - Culoz (France)

    1997-12-31

    This paper reports on a comparative study of the thermal performances of different refrigerants like R-22, R-134a, R-404A and R-407C when used as possible substitutes for the HCFC22 refrigerant in a given refrigerating machinery equipped with compact high performance plate exchangers. Thermal performances are compared in identical operating conditions. The behaviour of the two-phase exchange coefficient is analyzed with respect to the different parameters. The composition of the mixture after one year of operation has been analyzed too and the influence of oil on the performances is studied. (J.S.)

  2. 4 K to 20 K rotational-cooling magnetic refrigerator capable of 1-mW to >1-W operation

    International Nuclear Information System (INIS)

    Barclay, J.A.

    1980-02-01

    The low-temperature, magnetic entropy of certain single-crystal paramagnetic materials, such as DyPO 4 , changes dramatically as the crystal rotates in a magnetic field. A new magnetic refrigerator design based on the anisotropic nature of such materials is presented. The key advantages of the rotational-cooling concept are (1) a single, rotary motion is required, (2) magnetic field shaping is not a problem because the entire working material is in a constant field, and (3) the refrigerator can be smaller than comparable magnetic refrigerators because the working material is entirely inside the magnet at all times. The main disadvantage of the rotational-cooling concept is that small-dimension single crystals are required

  3. 30 CFR 56.4430 - Storage facilities.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Storage facilities. 56.4430 Section 56.4430 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE... Control Flammable and Combustible Liquids and Gases § 56.4430 Storage facilities. (a) Storage tanks for...

  4. Cryogenic refrigeration. (Latest citations from the Aerospace database). Published Search

    International Nuclear Information System (INIS)

    1993-09-01

    The bibliography contains citations concerning cryogenic refrigeration or cryocooling. Design, development, testing, and evaluation of cryogenic cooling systems are discussed. Design applications in spacecraft, magnet cooling, superconductors, liquid fuel storage, radioastronomy, and medicine are presented. Material properties at cryogenic temperatures and cryogenic rocket propellants are considered in separate bibliographies. (Contains 250 citations and includes a subject term index and title list.)

  5. 2016 German refrigeration and air conditioning meeting. Proceedings

    International Nuclear Information System (INIS)

    2016-01-01

    The following topics were dealt with: Large cryogenic facilities, relief valves, liquid helium, liquid-nitrogen and liquid hydrogen cooling, new concepts, foundations and materials of the heat-pump techniques, evaporation, phase-change materials, absorption, afterheat usage, ionic liquids, sorption, condensers, heat exchangers, back-cooling systems, refrigerants, caron dioxide, mobile applications, efficiency and optimization, air conditioning.

  6. A cooling concept of spent fuels in lag storage system

    International Nuclear Information System (INIS)

    Park, Jeong-Hwa; Yoo, Jae-Hyung; Park, Hyun-Soo

    1991-01-01

    A cooling concept of spent fuels by natural convection of hot cell air in storage pits was developed. Each storage pit was considered to be located below the hot cell floor and to accommodate only one spent fuel assembly. The aim of this study is to apply an appropriate cooling system to the design of a hot cell where considerable heat-generating fuels are handled. In such operations as disassembling, rod consolidation and packaging of spent fuels, a number of assemblies are on stand-by in the cell before and/or after the operations. A lag storage system can be used for temporary storage of spent fuels in nuclear facilities. Since the air in contact with bare fuel assemblies is potentially contaminated, it must be exhausted through high-efficiency particulate air (HEPA) filters. If the storage pit is completely isolated from the hot cell space, then it will require another separate ventilation system by forced convection of air, which will result in additional cost for the construction. In this work, however, a cooling system was proposed where natural convection of hot cell air itself is achieved by thermo-syphon. The cold air from the hot cell is supplied to the inlet provided at the bottom of each pit through the gap between the concrete pit wall and the interior thermal shield. This thermal shield is needed to form flow channels for cold and heated air, and to prevent the concrete from over-heating. The heated air exhausts from the outlet located at the top of cell wall. No additional HEPA filters are needed in this system because the heated air is routed back to the hot cell due to buoyancy-induced flow. The technical feasibility of this concept was validated by thermal analyses. As the key design constraints are the surface temperature of fuel cladding and the concrete temperature of the storage pit, the thermal analyses were focused on these parameters whether they follow within allowable limits or not. (author)

  7. Behavior of FFC refrigerants in the presence of refrigerant oils. Oelverhalten chlorfreier Kaeltemittel

    Energy Technology Data Exchange (ETDEWEB)

    Burke, M.; Kruse, H. (Hannover Univ. (Germany, F.R.). Inst. fuer Kaeltetechnik und Angewandte Waermetechnik)

    1990-01-01

    Looking for substitutes for the ozone-depleting refrigerants R12 and R22, investigations were made of the miscibility of FFC refrigerants (R23 - trifluoromethane CHF{sub 3}, R134a - tetrafluoroethane CH{sub 3}-CHF{sub 2}, and R152a - difluoroethane CH{sub 3}-CHF{sub 2}) with refrigerator oils. First experimental results reveal the refrigerants' behavior when mixed with mineral oils, alkylbenzene, PAG and ester-based oils. Mixtures of above refrigerants, especially R134a/R152a and R23/R152a as binary nonazeotropic mixtures, are considered conceivable substitutes. While addition of R23 reduces the mixture's flammability, addition of R152a improves the solubility of R134a in refrigerant oils. (orig./HW).

  8. Second generation waste package design and storage concept for the Yucca Mountain Repository

    International Nuclear Information System (INIS)

    Armijo, Joseph Sam; Kar, Piyush; Misra, Manoranjan

    2006-01-01

    The reference waste package design and operating mode to be used in the Yucca Mountain Repository is reviewed. An alternate (second generation) operating concept and waste package design is proposed to reduce the risk of localized corrosion of waste packages and to reduce repository costs. The second generation waste package design and storage concept is proposed for implementation after the initial licensing and operation of the reference repository design. Implementation of the second generation concept at Yucca Mountain would follow regulatory processes analogous to those used successfully to extend the design life and uprate the power of commercial light water nuclear reactors in the United States. The second generation concept utilizes the benefits of hot dry storage to minimize the potential for localized corrosion of the waste package by liquid electrolytes. The second generation concept permits major reductions in repository costs by increasing the number of fuel assemblies stored in each waste package, by eliminating the need for titanium drip shields and by fabricating the outer container from corrosion resistant low alloy carbon steel

  9. Terminology for refrigerating machinery in 5 languages with definitions. CECOMAF terminology English, French, German, Italian and Spanish. Terminologie fuer kaeltetechnische Erzeugnisse in 5 Sprachen mit Definitionen. CECOMAF Terminologie English, Francais, Deutsch, Italiano, Espanol

    Energy Technology Data Exchange (ETDEWEB)

    1986-01-01

    The dictionary covers the following topics: Directions for user, alphabetical list, subject index, main groups: Refrigerating systems and plants, compressors, heat exchangers and apparatus, control and safety devices, equipment for refrigerated storage and transport, refrigerators and refrigerated cabinets, special cooling and freezing equipment, miscellaneous; definitions for the above mentioned main groups, and corrections.

  10. Fast Adapting Ensemble: A New Algorithm for Mining Data Streams with Concept Drift

    Science.gov (United States)

    Ortíz Díaz, Agustín; Ramos-Jiménez, Gonzalo; Frías Blanco, Isvani; Caballero Mota, Yailé; Morales-Bueno, Rafael

    2015-01-01

    The treatment of large data streams in the presence of concept drifts is one of the main challenges in the field of data mining, particularly when the algorithms have to deal with concepts that disappear and then reappear. This paper presents a new algorithm, called Fast Adapting Ensemble (FAE), which adapts very quickly to both abrupt and gradual concept drifts, and has been specifically designed to deal with recurring concepts. FAE processes the learning examples in blocks of the same size, but it does not have to wait for the batch to be complete in order to adapt its base classification mechanism. FAE incorporates a drift detector to improve the handling of abrupt concept drifts and stores a set of inactive classifiers that represent old concepts, which are activated very quickly when these concepts reappear. We compare our new algorithm with various well-known learning algorithms, taking into account, common benchmark datasets. The experiments show promising results from the proposed algorithm (regarding accuracy and runtime), handling different types of concept drifts. PMID:25879051

  11. New materials for thermal energy storage in concentrated solar power plants

    Science.gov (United States)

    Guerreiro, Luis; Collares-Pereira, Manuel

    2016-05-01

    Solar Thermal Electricity (STE) is an important alternative to PV electricity production, not only because it is getting more cost competitive with the continuous growth in installed capacity, engineering and associated innovations, but also, because of its unique dispatch ability advantage as a result of the already well established 2-tank energy storage using molten salts (MS). In recent years, research has been performed, on direct MS systems, to which features like modularity and combinations with other (solid) thermal storage materials are considered with the goal of achieving lower investment cost. Several alternative materials and systems have been studied. In this research, storage materials were identified with thermo-physical data being presented for different rocks (e.g. quartzite), super concrete, and other appropriate solid materials. Among the new materials being proposed like rocks from old quarries, an interesting option is the incorporation of solid waste material from old mines belonging to the Iberian Pyritic Belt. These are currently handled as byproducts of past mine activity, and can potentially constitute an environmental hazard due to their chemical (metal) content. This paper presents these materials, as part of a broad study to improve the current concept of solar energy storage for STE plants, and additionally presents a potentially valuable solution for environmental protection related to re-use of mining waste.

  12. Optimization of a Two Stage Pulse Tube Refrigerator for the Integrated Current Lead System

    Science.gov (United States)

    Maekawa, R.; Matsubara, Y.; Okada, A.; Takami, S.; Konno, M.; Tomioka, A.; Imayoshi, T.; Hayashi, H.; Mito, T.

    2008-03-01

    Implementation of a conventional current lead with a pulse tube refrigerator has been validated to be working as an Integrated Current Lead (ICL) system for the Superconducting Magnetic Energy Storage (SMES). Realization of the system is primarily accounted for the flexibility of a pulse tube refrigerator, which does not posses any mechanical piston and/or displacer. As for an ultimate version of the ICL system, a High Temperature Superconducting (HTS) lead links a superconducting coil with a conventional copper lead. To ensure the minimization of heat loads to the superconducting coil, a pulse tube refrigerator has been upgraded to have a second cooling stage. This arrangement reduces not only the heat loads to the superconducting coil but also the operating cost for a SMES system. A prototype two-stage pulse tube refrigerator, series connected arrangement, was designed and fabricated to satisfy the requirements for the ICL system. Operation of the first stage refrigerator is a four-valve mode, while the second stage utilizes a double inlet configuration to ensure its confined geometry. The paper discusses the optimization of second stage cooling to validate the conceptual design

  13. Refrigerants and environment

    Science.gov (United States)

    Tsvetkov, O. B.; Laptev, Yu A.

    2017-11-01

    The refrigeration and air-conditioning industries are important sectors of the economy and represents about 15 % of global electricity consumptions. The chlorofluorocarbons also called CFCs are a class of refrigerants containing the halogens chlorine and/or fluorine on a carbon skeleton. Because of their environmental impact the Montreal Protocol was negotiated in 1987 to limit the production of certain CFCs and hydrochlirofluorocarbons (HCFCs) in developed and developing countries. The halogenated refrigerants are depleting the ozone layer also major contribution to the greenhouse effect. To be acceptable as a refrigerant a fluid must satisfy a variety of thermodynamic criteria and should be environment friendly with zero Ozone Depletion Potential and low Global Warming Potential. The perspective of a future phase down of HFCs is considered in this report taking into account a strategy for the phase out of HCFCs and perspective of choosing of various refrigerant followed by safety issues.

  14. The underground retrievable storage (URS) high-level waste management concept

    International Nuclear Information System (INIS)

    Ramspott, L.D.

    1991-01-01

    This papers presents the concept of long-term underground retrievable storage (URS) of spent reactor fuel in unsaturated rock. Emplacement would be incremental and the system is planned to be experimental and flexible. The rationale for retrievability is examined, and a technical basis for 300-year retrievability is presented. Maximum isolation is the rationale for underground as opposed to surface storage. Although the potential repository site at Yucca Mountain Nevada would be suitable for a URS, alternate sites are discussed. The technical issues involved in licensing a URS for 300 years are simpler than licensing a 10,000 year repository. 16 refs

  15. Prediction of Dangerous Time in Case Hydrocarbon Refrigerant Leaks into Household Refrigerator Cabinet

    Science.gov (United States)

    Meguro, Takatoshi; Kaji, Nobufuji; Miyake, Kunihiro

    Hydrocarbon refrigerators are now on sale in European countries. However, hydrocarbons are flammable. A common claim is that concentration of hydrocarbon in the refrigerator could exceed the lower explosive limit by a sudden leak and then a spark ignites a flame causing overpressure. There is the need of the studies on potential risks originated from the use of flammable refrigerants. Thus, the flow rate of the fresh air into the refrigerator cabinet has been defined experimentally, and the spatial average concentration in the refrigerator cabinet has been analyzed theoretically to predict the dangerous time in excess of the lower explosive limit.

  16. Thermoeconomic Optimization of Cascade Refrigeration System Using Mixed Carbon Dioxide and Hydrocarbons at Low Temperature Circuit

    Directory of Open Access Journals (Sweden)

    Nasruddin Nasruddin

    2016-12-01

    Full Text Available Many applications and industrial processes require very low cooling temperature, such as cold storage in the biomedical field, requiring temperature below -80 °C. However,single-cycle refrigeration systems can only achieve the effective cooling temperature of -40 °C and, also, the performance of the cycle will decrease drastically for cooling temperatures lower than -35°C. Currently, most of cascade refrigeration systems use refrigerants that have ozone depletion potential (ODP and global warming potential (GWP, therefore, in this study, a cascade system is simulated using a mixture of environmentally friendly refrigerants, namely, carbon dioxide and a hydrocarbon (propane, ethane or ethylene as the refrigerant of the low temperature circuit. A thermodynamic analysis is performed to determine the optimal composition of the mixture of carbon dioxide and hydrocarbons in the scope of certain operating parameters. In addition, an economic analysis was also performed to determine the annual cost to be incurred from the cascade refrigeration system. The multi-objective/thermoeconomic optimization points out optimal operating parameter values of the system, to addressing both exergy efficiency and its relation to the costs to be incurred.

  17. Conception of modular hydrogen storage systems for portable applications

    International Nuclear Information System (INIS)

    Paladini, V.; Miotti, P.; Manzoni, G.; Ozebec, J.

    2003-01-01

    Hydrogen, till now the most prominent candidate as a future sustainable energy carrier, yields a gravimetric energy density three times as high as liquid hydrocarbon. Furthermore it is proven to be the most environmentally friendly fuel. Unfortunately, a few components regarding storage and tank solutions have not yet reached a technology level required for broad use. Thus, we intend to propose solutions and device concepts for both devices everyday use and space applications. This contribution assesses both state of the art of storage materials and existing technologies of power generation systems for application in portable devices. The aim of this work is to define the characteristics of a modular system, being suitable for a wide range of different devices, operating on advanced metal hydrides as the active hydrogen supply component. The concept has been studied and modelled with respect to volumes, mass and power requirements of different devices. The smallest system developed is intended to run, for example, a mobile phone. Minor tuning and straightforward scale up of this power supply module should make it suitable for general applicability in any portable device. (author)

  18. Theoretical study on a novel dual-nozzle ejector enhanced refrigeration cycle for household refrigerator-freezers

    International Nuclear Information System (INIS)

    Zhou, Mengliu; Wang, Xiao; Yu, Jianlin

    2013-01-01

    Highlights: • A novel dual-nozzle ejector enhanced refrigeration cycle is proposed. • The novel cycle is evaluated by using the developed mathematical model. • The results show the performances of the novel cycle could be significantly improved. • The novel cycle shows its promise in household refrigerator-freezers applications. - Abstract: In this study, a novel dual-nozzle ejector enhanced refrigeration cycle is presented for dual evaporator household refrigerator-freezers. The proposed ejector equipped with two nozzles can efficiently recover the expansion work from cycle throttling processes and enhance cycle performances. The performances of the novel cycle are evaluated by using the developed mathematical model, and then compared with that of the conventional ejector enhanced refrigeration cycle and basic vapor-compression refrigeration cycle. The simulation results show that for the given operating conditions, the coefficient of performance (COP) of the novel cycle using refrigerant R134a is improved by 22.9–50.8% compared with that of the basic vapor-compression refrigeration cycle, and the COP improvement is 10.5–30.8% larger than that of the conventional ejector enhanced refrigeration cycle. The further simulation results of the novel cycle using refrigerant R600a indicate that the cycle COP and volumetric refrigeration capacity could be significantly improved

  19. Characterization and Monitoring of a Self-Constructible Photovoltaic-Based Refrigerator

    Directory of Open Access Journals (Sweden)

    Claudio Del Pero

    2016-09-01

    Full Text Available At present, in the developing countries, the power grids do not reach every small town and, even when they do, they are not reliable. For this reason, preservation of food and medicines is a sensitive issue for a large number of people. This work introduces the characterization of a new, self-constructible refrigerator, powered by photovoltaic (PV energy, suitable for the preservation of food in rural villages, with a specific focus on Africa’s tropical-equatorial belt. A thermally-insulated envelope, equipped with thermal energy storage, has been designed to be built on-site, by using local materials, and assembled with technical components (direct current (DC compressor, heat exchangers, photovoltaic module. The monitoring activity presented in this work was carried out on a first prototype of the system and enabled the validation of numerical simulations, aimed at assessing its appropriate operability under laboratory conditions. In particular, the work demonstrates that the basic module of the refrigerator, with a net capacity of 250 L and an ice storage of 12.5 kg, is able to maintain an internal temperature below 10 °C also in critical boundary conditions.

  20. Mining Concept Maps from News Stories for Measuring Civic Scientific Literacy in Media

    Science.gov (United States)

    Tseng, Yuen-Hsien; Chang, Chun-Yen; Rundgren, Shu-Nu Chang; Rundgren, Carl-Johan

    2010-01-01

    Motivated by a long-term goal in education for measuring Taiwanese civic scientific literacy in media (SLiM), this work reports the detailed techniques to efficiently mine a concept map from 2 years of Chinese news articles (901,446 in total) for SLiM instrument development. From the Chinese news stories, key terms (important words or phrases),…

  1. Development of a battery-free solar refrigerator

    Energy Technology Data Exchange (ETDEWEB)

    Ewert, Michael K; Bergeron, David J. III [Houston, TX (United States)

    2000-07-01

    Recent technology developments and a systems engineering design approach have led to the development of a practical battery-free solar refrigerator as a spin-off of NASA's aerospace refrigeration research. Off-grid refrigeration is a good application of solar photovoltaic (PV) power thermal storage is incorporated and a direct connection is made between the cooling system and the PV panel. This was accomplished by integrating water as a phase-change material into a well-insulated refrigerator cabinet and by developing a microprocessor-based control system that allows direct connection of a PV panel to a variable-speed compressor. This second innovation also allowed peak power-point tracking from the PV panel and elimination of batteries from the system. First a laboratory unit was developed to prove the concept and then a commercial unit was produced and deployed in a field test. The laboratory unit was used to test many different configurations including thermoelectric., Stirling and vapor compression cooling systems. The final configuration used a vapor compression cooling cycle, vacuum insulation, a passive condenser, and integral evaporator/thermal storage tank, two 77 watt PV panels, and the novel controller mentioned above. The system's only moving part was the variable-speed BD35 compressor made by Danfoss. The 365 liter cabinet stayed cold with as a little as 274 watt-hours per day average PV power. Battery-free testing was conducted for several months with very good results. The amount of thermal storage, size of compressor, and power of PV panels connected can all be adjusted to optimize the design for a given application and climate. In the commercial unit, vacuum insulation and the stainless steel thermal storage tank were not used in order to reduce cost and make the technology commercially viable. This unit started with a 142 liter, mass-produced chest freezer cabinet that had the evaporator integrated into its inner walls. Its compressor

  2. Effect of different radiation dose rates on refrigerated mechanically deboned chicken meat

    Energy Technology Data Exchange (ETDEWEB)

    Brito, Poliana de Paula; Gomes, Heliana de Azevedo; Fukuma, Henrique Takuji [Comissao Nacional de Energia Nuclear (CNEN), Pocos de Caldas, MG (Brazil). Coordenacao de Laboratorios de Pocos de Caldas (COLAB)]. E-mail: polibrito@yahoo.com.br; hgomes@cnen.gov.br; htfukuma@cnen.gov.br

    2005-07-01

    Samples of mechanically deboned chicken meat (MDCM) were irradiated while frozen with doses of 0.0 kGy, 3.0 kGy - 4.04 kGy.h{sup -1} and 3.0 kGy - 0.32 kGy.h{sup -1}. Individual lots of irradiated and non irradiated samples were evaluated for Substances Reactive to Thiobarbituric Acid (TBARS) and total count of psychotropic bacteria, while in refrigerated storage (2 {+-}1 deg C), for 11 days. The values for percentage of recovery for 1,1,3,3-tetraetoxipropane (TEP) and for conversion of the K value for samples irradiated with 3.0 kGy - 4.35 kGy.h{sup -1} and 3.0 kGy - 0.3 kGy.h{sup -1} and samples non irradiated were, respectively: 80.3 %, 70.3 % and 80.4 % and 9.1, 11.2 and 9.1. The results showed that there was not a difference for the TBARS values when irradiated and non irradiated samples were compared up to the forth day of refrigerated storage. Between the seventh and eleventh day of storage the TBARS values increased gradually when values obtained for non irradiated and those samples irradiated with doses of 3.0 kGy - 0.3 kGy.h{sup -1} and 3.0 kGy - 4.35 kGy.h{sup -1} were compared. The average values for psychotropic bacteria obtained for samples non irradiated and those irradiated with doses of 3.0 kGy - 0.32 kGy.h{sup -1} and 3.0 kGy - 4.04 kGy.h{sup -1}, during the second and eleventh day of frozen storage were respectively 6.68 log (UFC.g{sup -1}), 2.87 log (UFC.g{sup -1}) and 2.66 log (UFC.g{sup -1}). When both variables were evaluated, it was verified that samples irradiated with a dose rate of 0.32 kGy.{sup -1} presented the smallest values of TBARS than those samples irradiated with a dose rate of 4.04 kGy.h{sup -1}, from the seventh day of refrigerated storage and bacterial count within the legal limits allowed by the regulation, being considered the best dosage rate for processing MDCM, in the conditions of the present study. (author)

  3. Eggs and Poultry Purchase, Storage, and Preparation Practices of Consumers in Selected Asian Countries

    Directory of Open Access Journals (Sweden)

    Kadri Koppel

    2014-01-01

    Full Text Available The objective of this study was to begin characterizing purchase, storage, handling, and preparation of poultry products and eggs by selected consumers in three Asian countries: India, Korea, and Thailand. Approximately 100 consumers in each location were recruited to participate in this study. The consumers were surveyed about eggs and poultry purchase behavior characteristics, such as temperatures and locations, storage behavior, such as storage locations in the refrigerator or freezer, preparation behavior, such as washing eggs and poultry before cooking, and handling behavior, such as using cutting boards during cooking. The results indicated differences in purchase and storage practices of raw eggs. Most Korean consumers purchased refrigerated eggs and stored the eggs in the refrigerator, while Indian and Thai consumers bought eggs that were stored at room temperature, but would refrigerate the eggs at home. Approximately half of the consumers in each country froze raw meat, poultry, or seafood. Food preparation practices showed potential for cross-contamination during cooking, such as using the same cutting board for different kinds of foods or not washing hands with soap and water. The results presented in this pilot study may lead to development of educational messages and raising consumer awareness of food safety practices in Asian countries.

  4. Eggs and Poultry Purchase, Storage, and Preparation Practices of Consumers in Selected Asian Countries

    Science.gov (United States)

    Koppel, Kadri; Suwonsichon, Suntaree; Chitra, Uma; Lee, Jeehyun; Chambers, Edgar

    2014-01-01

    The objective of this study was to begin characterizing purchase, storage, handling, and preparation of poultry products and eggs by selected consumers in three Asian countries: India, Korea, and Thailand. Approximately 100 consumers in each location were recruited to participate in this study. The consumers were surveyed about eggs and poultry purchase behavior characteristics, such as temperatures and locations, storage behavior, such as storage locations in the refrigerator or freezer, preparation behavior, such as washing eggs and poultry before cooking, and handling behavior, such as using cutting boards during cooking. The results indicated differences in purchase and storage practices of raw eggs. Most Korean consumers purchased refrigerated eggs and stored the eggs in the refrigerator, while Indian and Thai consumers bought eggs that were stored at room temperature, but would refrigerate the eggs at home. Approximately half of the consumers in each country froze raw meat, poultry, or seafood. Food preparation practices showed potential for cross-contamination during cooking, such as using the same cutting board for different kinds of foods or not washing hands with soap and water. The results presented in this pilot study may lead to development of educational messages and raising consumer awareness of food safety practices in Asian countries. PMID:28234307

  5. Is Toscana A Formal Concept Analysis Based Solution In Web Usage Mining?

    Directory of Open Access Journals (Sweden)

    Dan-Andrei SITAR-TĂUT

    2012-01-01

    Full Text Available Analyzing large amount of data come from web logs represents a complex, but challenging nowadays problem with implication in various fields, thing that lets open a way for theoretically infinite approaches an implementations. The main goal of our paper represents the possibility of applying the formal concept analysis as viable solution of sustaining the web mining process, based on a technological open-source solution called TOSCANA.

  6. Retrievable storage concept designs. Final report

    International Nuclear Information System (INIS)

    Nickell, R.E.

    1979-01-01

    Three tasks related to the reference design of retrievable storage canisters for radioactive waste have been completed. The three tasks consist of the reference design itself, the definition of failure modes most appropriate for structural integrity determinations for the reference canister, and the development of a failure methodology for the structural integrity of the containers. The reference design is a sealed storage canister concept based upon the waste isolation pilot plant (WIPP) design, with slight modifications. The modifications consist of an alternate lifting yoke arrangement for the top head and a revised bottom head design for absorption of impact energy. Welded closures provide the seal at each end. Overpacking is considered as a possibility, but is not included in the preliminary reference design. The four failure modes that are deemed the most appropriate for the design of the reference canister are: (i) a loss of functional capability; (ii) ductile rupture of the canister; (iii) buckling of the structural members; and (iv) stress corrosion cracking. Failure scenarios are provided for each of the relevant failure modes. In addition, a failure methodology based upon the distribution of demand and the distribution of capacity for the structural members, with respect to each failure mode, is proffered

  7. Developments in magnetocaloric refrigeration

    International Nuclear Information System (INIS)

    Brueck, Ekkes

    2005-01-01

    Modern society relies on readily available refrigeration. Magnetic refrigeration has three prominent advantages compared with compressor-based refrigeration. First, there are no harmful gases involved; second, it may be built more compactly as the working material is a solid; and third, magnetic refrigerators generate much less noise. Recently a new class of magnetic refrigerant-materials for room-temperature applications was discovered. These new materials have important advantages over existing magnetic coolants: they exhibit a large magnetocaloric effect (MCE) in conjunction with a magnetic phase-transition of first order. This MCE is larger than that of Gd metal, which is used in the demonstration refrigerators built to explore the potential of this evolving technology. In the present review we compare the different materials considering both scientific aspects and industrial applicability. Because fundamental aspects of MCE are not so widely discussed, we also give some theoretical considerations. (topical review)

  8. Energy performance of supermarket refrigeration and air conditioning integrated systems working with natural refrigerants

    International Nuclear Information System (INIS)

    Cecchinato, Luca; Corradi, Marco; Minetto, Silvia

    2012-01-01

    The current trends in commercial refrigeration aim at reducing the synthetic refrigerant charge, either by minimising the internal volume of the circuit or by utilising natural refrigerants, and at energy saving. The energy efficiency of supermarkets can be improved by optimising components design, recovering thermal and refrigerating energy, adopting innovative technology solutions, integrating the HVAC system with medium temperature and low temperature refrigeration plants and, finally, reducing thermal loads on refrigerated cases. This study aims at investigating the performance of different lay-out and technological solutions where only natural refrigerants are used and at finding the potential for improving energy efficiency over the traditional systems in different climates. In the analysis, chillers and heat pumps working with ammonia or propane, medium temperature systems working with ammonia or propane and carbon dioxide as heat transfer fluid or with carbon dioxide as the refrigerant and low temperature systems working with carbon dioxide are considered and benchmarked with a state-of-the-art HFCs based plant. The most efficient investigated solution enables an annual energy saving higher than 15% with respect to the baseline solution for all the considered climates. - Highlights: ► Different natural refrigerants supermarket HVAC and R integrated systems are analysed. ► Some of the proposed solutions offer a significant benefit over the baseline one. ► Up to 18.7% energy saving is achieved in the considered climates. ► The refrigeration unit condensation by the AC chiller offers the poorest results.

  9. Geomechanical characterization of the Upper Carboniferous under thermal stress for the evaluation of a High Temperature - Mine Thermal Energy Storage (HT-MTES)

    Science.gov (United States)

    Hahn, Florian; Brüggemann, Nina; Bracke, Rolf; Alber, Michael

    2017-04-01

    The goal of this R&D project is to create a technically and economically feasible conceptual model for a High Temperature - Mine Thermal Energy Storage (HT-MTES) for the energetic reuse of a mine on the example of the Prosper-Haniel coal mine in Bottrop, Germany. This project is funded by the "Initiative Energy Storage" program of the German Federal Ministries BMWi, BMU and BMBF. At the end of 2018, the last operative coal mine in North Rhine-Westphalia, Germany (Prosper-Haniel), is going to be closed down, plugged and abandoned. Large amounts of subsurface infrastructures, resembled mainly by open parts of former galleries and mining faces are going to be flooded, after the mine is closed down and therefore have the potential to become an enormous geothermal reservoir for a seasonal heat storage. During the summer non-used (waste) heat from solar thermal power plants, garbage incineration, combined heat and power plants (CHP) or industrial production processes can be stored within dedicated drifts of the mine. During the winter season, this surplus heat can be extracted and directly utilized in commercial and/or residential areas. For the evaluation of such a HT-MTES within a former coal mine, the corresponding geomechanical parameters of the Upper Carboniferous under thermal stress needs to be evaluated. Therefore the main rock types of the Upper Carboniferous (claystone, siltstone and sandstone) are subject to a geomechanical characterization before and after thermal cyclic loadings of temperatures up to 200 °C. The samples have been collected directly from the coal mine Prosper-Haniel within a depth range of 1000 - 1200 m. Unconfined compressive and tensile strengths, as well as triaxial tests were performed at room temperature. Furthermore, a range of petrophysical properties like density, thin-section analysis and P-wave velocities were determined. First results show an indication that the overall strength properties of the samples are not effected by

  10. Chilled storage of foods - principles

    Science.gov (United States)

    Chilled storage is the most common method for preserving perishable foods. The consumers’ increasing demand for convenient, minimally processed foods has caused food manufacturers to increase production of refrigerated foods worldwide. This book chapter reviews the development of using low tempera...

  11. Effects of Gelatin-Based Edible Films Enriched with Laurel Essential Oil on the Quality of Rainbow Trout (Oncorhynchus mykiss Fillets During Refrigerated Storage

    Directory of Open Access Journals (Sweden)

    Tuba Baygar

    2014-01-01

    Full Text Available The effects of gelatin films enriched with laurel leaf essential oil on the quality of rainbow trout (Oncorhynchus mykiss during refrigerated storage at (4±1 °C were examined over a period of 26 days. Fish fillets were wrapped with 8 % gelatin films containing 0, 0.1 and 1 % (by volume per mass of laurel essential oil and vacuum packaged. Sensory (raw and cooked fish, microbiological (total viable counts, psychrotrophic bacteria counts, Enterobacteriaceae and lactic acid bacteria and chemical (proximate composition, pH, total volatile base nitrogen (TVB-N, thiobarbituric acid (TBA, free fatty acid (FFA and peroxide value (PV analysis, and colour measurement were carried out during the storage period and shelf-life was determined periodically. The obtained results showed that the gelatin film enriched with laurel essential oil was suitable for the preservation of rainbow trout fillet and the ability of laurel essential oil to preserve the film depended on its ratio. Combined effects of gelatin film and laurel essential oil (1 % by volume per mass was efficient in maintaining the quality characteristics at an acceptable level up to 22 days of storage, while the control and gelatin film without the essential oil reached an unacceptable level at 15 and 20 days, respectively.

  12. Assessment and study of existing concepts and methods of cryogenic refrigeration for superconducting transmission cables. Final report

    International Nuclear Information System (INIS)

    Kadi, F.J.; Longsworth, R.C.

    1976-02-01

    A review of current programs to develop superconducting power transmission shows that current plans require helium refrigerators operating at 5 to 13 0 K and 3 to 15 atm pressure with compressor power input in the range of 1,300 to 3,500 HP. Future requirements will probably trend toward slightly higher temperatures and larger refrigerators. Present large helium refrigerators and APCI standard nitrogen plants were studied and an average outage frequency of about 18 per year is found to be typical for both. Cost and reliability studies of alternate refrigeration systems based on studies of components shows that the best current system which would have a failure rate of once in 20 years would consist of two full size oil flooded screw compressors in parallel, manifolded to two full size cold boxes and a liquid helium back up dewar. The principal area of development needed to implement this system is in the switch over mechanisms. These include switching to an auxillary power source in the event of power interruption, switching to the standby compressor, and switching to the back up liquid helium dewar. Costs are projected as being only slightly greater than preliminary estimates

  13. Social big data mining

    CERN Document Server

    Ishikawa, Hiroshi

    2015-01-01

    Social Media. Big Data and Social Data. Hypotheses in the Era of Big Data. Social Big Data Applications. Basic Concepts in Data Mining. Association Rule Mining. Clustering. Classification. Prediction. Web Structure Mining. Web Content Mining. Web Access Log Mining, Information Extraction and Deep Web Mining. Media Mining. Scalability and Outlier Detection.

  14. COP improvement of refrigerator/freezers, air-conditioners, and heat pumps using nonazeotropic refrigerant mixtures

    Science.gov (United States)

    Westra, Douglas G.

    1993-01-01

    With the February, 1992 announcement by President Bush to move the deadline for outlawing CFC (chloro-fluoro-carbon) refrigerants from the year 2000 to the year 1996, the refrigeration and air-conditioning industries have been accelerating their efforts to find alternative refrigerants. Many of the alternative refrigerants being evaluated require synthetic lubricants, are less efficient, and have toxicity problems. One option to developing new, alternative refrigerants is to combine existing non-CFC refrigerants to form a nonazeotropic mixture, with the concentration optimized for the given application so that system COP (Coefficient Of Performance) may be maintained or even improved. This paper will discuss the dilemma that industry is facing regarding CFC phase-out and the problems associated with CFC alternatives presently under development. A definition of nonazeotropic mixtures will be provided, and the characteristics and COP benefits of nonazeotropic refrigerant mixtures will be explained using thermodynamic principles. Limitations and disadvantages of nonazeotropic mixtures will be discussed, and example systems using such mixtures will be reviewed.

  15. Technical Aspects Regarding the Preservation of Dry Onions in Different Storage Conditions

    Directory of Open Access Journals (Sweden)

    Marian Vintila

    2014-11-01

    Full Text Available Research refers to the ability to maintain the quality of dry onions in different conditions of temperature, the three varieties used in experimentation (De Buzau, Daytona and Countach being stored after proper preparation at ambient temperature (+20…+22°C, refrigerated (+10…+12°C and cold conditions (+3…+5°C. Storage life, the level of weight (mass and decay losses and evolution of some chemical components determined from the 9 variants led to the conclusion that the best results were obtained by De Buzau variety for storage under ambient conditions and Daytona variety for storage under refrigerated and cold conditions. Moreover large differences between varieties and their behavior depending on storage conditions require choosing resistant cultivars and optimum storage temperatures according to destination and period of marketing or consumption.

  16. Conceptual design of a 0.1 W magnetic refrigerator for operation between 10 K and 2 K

    International Nuclear Information System (INIS)

    Helvensteijn, B.P.M.; Kashani, A.

    1990-01-01

    The design of a magnetic refrigerator for space applications is discussed. The refrigerator is to operate in the temperature range of 10 K-2 K, at a 2 K cooling power of 0.10 W. As in other magnetic refrigerators operating in this temperature range GGG has been selected as the refrigerant. Crucial to the design of the magnetic refrigerator are the heat switches at both the hot and cold ends of the GGG pill. The 2 K heat switch utilizes a narrow He II filled gap. The 10 K heat switch is based on a narrow helium gas gap. For each switch, the helium in the gap is cycled by means of activated carbon pumps. The design concentrates on reducing the switching times of the pumps and the switches as a whole. A single stage system (one magnet; one refrigerant pill) is being developed. Continuous cooling requires the fully stationary system to have at least two stages running parallel/out of phase with each other. In order to conserve energy, it is intended to recycle the magnetic energy between the magnets. To this purpose, converter networks designed for superconducting magnetic energy storage are being studied. 17 refs

  17. ARTI Refrigerant Database

    Energy Technology Data Exchange (ETDEWEB)

    Cain, J.M. (Calm (James M.), Great Falls, VA (United States))

    1993-04-30

    The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R-717 (ammonia), ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents to accelerate availability of the information and will be completed or replaced in future updates.

  18. ARTI Refrigerant Database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1994-05-27

    The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  19. Work on decommissioning of Asse II mine

    International Nuclear Information System (INIS)

    Kappei, G.

    2006-01-01

    This is a historical contribution, starting with a description of the active time of this former salt mine. This is followed by an outline of the time of storage of radioactive materials, followed by the time of research and development work. Backfilling of the southern part was the first step to decommissioning. After describing these activities, the boundary conditions to be considered in decommissioning are described, as are the steps involved in the closing-down concept. A status report on the current situation is given as well. (orig.)

  20. Design optimization of superconducting magnetic energy storage coil

    Energy Technology Data Exchange (ETDEWEB)

    Bhunia, Uttam, E-mail: ubhunia@vecc.gov.in; Saha, Subimal; Chakrabarti, Alok

    2014-05-15

    Highlights: • We modeled the optimization formulation that minimizes overall refrigeration load into the SMES cryostat. • Higher the operating current reduces the dynamic load but increases static heat load into the cryostat. • Higher allowable hoop stress reduces both coil volume and refrigeration load. • The formulation can be in general be utilized for any arbitrary specification of SMES coil and conductor type. - Abstract: An optimization formulation has been developed for a superconducting magnetic energy storage (SMES) solenoid-type coil with niobium titanium (Nb–Ti) based Rutherford-type cable that minimizes the cryogenic refrigeration load into the cryostat. Minimization of refrigeration load reduces the operating cost and opens up the possibility to adopt helium re-condensing system using cryo-cooler especially for small-scale SMES system. Dynamic refrigeration load during charging or discharging operational mode of the coil dominates over steady state load. The paper outlines design optimization with practical design constraints like actual critical characteristics of the superconducting cable, maximum allowable hoop stress on winding, etc., with the objective to minimize refrigeration load into the SMES cryostat. Effect of design parameters on refrigeration load is also investigated.

  1. Magnon-driven quantum dot refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yuan; Huang, Chuankun; Liao, Tianjun; Chen, Jincan, E-mail: jcchen@xmu.edu.cn

    2015-12-18

    Highlights: • A three-terminal quantum dot refrigerator is proposed. • The effects of magnetic field, applied voltage, and polarization are considered. • The region that the system can work as a refrigerator is determined. • Two different magnon-driven quantum dot refrigerators are compared. - Abstract: A new model of refrigerator consisting of a spin-splitting quantum dot coupled with two ferromagnetic reservoirs and a ferromagnetic insulator is proposed. The rate equation is used to calculate the occupation probabilities of the quantum dot. The expressions of the electron and magnon currents are obtained. The region that the system can work in as a refrigerator is determined. The cooling power and coefficient of performance (COP) of the refrigerator are derived. The influences of the magnetic field, applied voltage, and polarization of two leads on the performance are discussed. The performances of two different magnon-driven quantum dot refrigerators are compared.

  2. Applicability of ASST-A helium refrigeration system for JLab End Station Refrigerator

    Science.gov (United States)

    Hasan, N.; Knudsen, P.; Ganni, V.

    2017-12-01

    The MØLLER experiment at Jefferson Lab (JLab) is a high power (5 kW) liquid hydrogen target scheduled to be operational in the 12 GeV-era. At present, cryogenic loads and targets at three of JLab’s four experimental halls are supported by the End Station Refrigerator (ESR) - a CTI/Helix 1.5 kW 4.5 K refrigerator. It is not capable of supporting the high power target load and a capacity upgrade of the ESR cryogenic system is essential. The ASST-A helium refrigeration system is a 4 kW 4.5 K refrigerator. It was designed and used for the Superconducting Super Collider Lab (SSCL) magnet string test and later obtained by JLab after the cancellation of that project. The modified ASST-A refrigeration system, which will be called ESR-II along with a support flow from JLab’s Central Helium Liquefier (CHL) is considered as an option for the End Station Refrigerator capacity upgrade. The applicability of this system for ESR-II under varying load conditions is investigated. The present paper outlines the findings of this process study.

  3. A study of alternative refrigerants for the refrigeration and air conditioning sector in Mauritius

    Science.gov (United States)

    Dreepaul, R. K.

    2017-11-01

    The most frequently used refrigerants in the refrigeration and air conditioning (RAC) sector in Mauritius are currently hydrochlorofluorocarbons (HCFC) and hydrofluorocarbons (HFC). However, because of their strong influence on global warming and the impact of HCFCs on the ozone layer, refrigerants such as ammonia (NH3), carbon dioxide (CO2) and Hydrocarbons (HC), having minimal impact on the environment, are being considered. So far, HCs have only been safely used in domestic refrigeration. Ammonia has been used mainly for industrial refrigeration whereas CO2 is still under study. In this paper, a comparative study of the various feasible alternatives is presented in a survey that was undertaken with major stake holders in the field. The retrofitting possibility of existing equipment was assessed and safety issues associated with each refrigerant were analysed. The major setback of hydrocarbons as a widely accepted refrigerant is its flammability which was considered as a major safety hazard by the majority of respondents in the survey and the main advantages are the improved equipment coefficient of performance (COP) and better TEWI factor. This resulted in a 12 % drop in energy consumption. Despite the excellent thermodynamic properties of ammonia, its use has mainly been confined to industrial refrigeration due to its toxicity. In Mauritius, the performance of ammonia in air conditioning is being evaluated on a pilot basis. The major setback of carbon dioxide as a refrigerant is the high operating pressure which is considered a safety hazard. The high initial investment cost and the lack of qualified maintenance technician is also an issue. The use of CO2 is mainly being considered in the commercial refrigeration sector.

  4. Improvement in the storability and microbiological safety of minced meat products under refrigerated storage by a combination of irradiation and microbe-inhibiting physico-chemical factors

    International Nuclear Information System (INIS)

    Banati, D.; Farkas, J.; Andrassy, E.

    1992-01-01

    The storability of minced pork refrigerated at +2 C/degrees/ was examined after the following treatments: 1. vacuum packaging, 2. reduction of meat pH from 6 to 5.4 using ascorbic acid and acidic sodium pyrophosphate, and 3. combination of the latter treatment with gamma irradiation at a dose of 1 kGy. Low pH was sufficient in itself to improve storability by 2-6 days. Irradiation alone or combined with vacuum packaging prolonged storability by 4-9 days. A reduction in pH combined with irradiation did not give any further improvement in storability, storage for more than 3 weeks led to non-microbiological changes. The normal storage life of vacuum-packed beef sausages (consisting of beef, cereals, spices) is 12 days at 0-+2 C/degrees/, which could be increased to 30 days by irradiation (2 kGy or by reducing the water activity to 0.945 with glycerine

  5. A case-based reasoning tool for breast cancer knowledge management with data mining concepts and techniques

    Science.gov (United States)

    Demigha, Souâd.

    2016-03-01

    The paper presents a Case-Based Reasoning Tool for Breast Cancer Knowledge Management to improve breast cancer screening. To develop this tool, we combine both concepts and techniques of Case-Based Reasoning (CBR) and Data Mining (DM). Physicians and radiologists ground their diagnosis on their expertise (past experience) based on clinical cases. Case-Based Reasoning is the process of solving new problems based on the solutions of similar past problems and structured as cases. CBR is suitable for medical use. On the other hand, existing traditional hospital information systems (HIS), Radiological Information Systems (RIS) and Picture Archiving Information Systems (PACS) don't allow managing efficiently medical information because of its complexity and heterogeneity. Data Mining is the process of mining information from a data set and transform it into an understandable structure for further use. Combining CBR to Data Mining techniques will facilitate diagnosis and decision-making of medical experts.

  6. Combined Thermal Management and Power Generation Concept for the Spent Fuel Dry Storage Cask

    International Nuclear Information System (INIS)

    Kim, In Guk; Bang, In Cheol

    2017-01-01

    The management of the spent nuclear fuel generated by nuclear power plants is a major issue in Korea due to insufficient capacity of the wet storage pools. Therefore, it is considered that dry storage system is the one possible solution for storing spent fuel. A dual-purpose metal cask (transportation and storage) is currently developing in Korea. This cask has 21 of fuel assemblies and 16.8 kW of maximum decay heat. To evaluate the critical safety in normal/off normal and accident conditions, critical stabilities were conducted by using CSAS 6.0. The experimental investigation of heat removal of a concrete storage cask was also conducted under normal, off normal and accident conditions. The results of the evaluation showed a good safety of the dry storage cask. The results showed the enhanced thermal performance according to modification of flow rate. To verify combined thermal management and power generation concept, a new type of test facility for dry storage cask was designed in 1/10 scale of concrete dry storage cask. The experimental study involved the cooling methods that are an integrated system on the top of the dry cask and air flow path on the canister wall. The results showed the temperature distribution of the wall and inside of the dry cask at the normal condition. The influence of the change of the heat load and cooling system were investigated. The heat removal by the integrated system is approximately 20% of the total heat removal of the dry cask with reduced wall temperature. In these tests, economic analysis is conducted by applying the concept of the cost and efficiency. Under different decay power cases, the energy efficiency of the heat pipe and Stirling engine are determined and compared based on experimental results. The average efficiencies of the Stirling engine were the range of 2.375 to 3.247% under the power range of 35– 65W. These results showed that advanced dry storage concept had a better cooling performance in comparison with

  7. Gamma irradiation in the control of pathogenic bacteria in refrigerated ground chicken meat; Irradiacao gama no controle de bacterias patogenicas em carne de frango refrigerada

    Energy Technology Data Exchange (ETDEWEB)

    Spoto, Marta Helena Fillet; Alcarde, Andre Ricardo; Gurgel, Maria Silvia do Amaral; Blumer, Lucimara; Walder, Julio Marcos Melges; Domarco, Rachel Elisabeth [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Lab. de Irradiacao de Alimentos e Radioentomologia]. E-mail: aalcarde@cena.usp.br; Gallo, Claudio Rosa [Sao Paulo Univ., Piracicaba, SP (Brazil). Escola Superior de Agricultura Luiz de Queiroz

    2000-09-01

    This work evaluated the effect of gamma radiation on reducing the population of Staphylococcus aureus, Escherichia coli nd Salmonella typhimurium in ground chicken breast stored under refrigeration. The experiment included a control and 4 doses of gamma radiation ( 2.0, 4.0, 6.0 and 8.0 kGy) along with 5 periods of storage under refrigeration ( 1, 7 14, 21 and 28 days). Samples of ground chicken breast were inoculated with Staphylococcus aureus (ATCC 14458), Escherichia coli (ATCC 11105) and Salmonella typhimurium (ATCC 0626), irradiated at temperatures between 4 and 8 deg C and stored under refrigeration (5 deg C) for 28 days. The increased radiation dose and period of storage under refrigeration caused a reduction of Staphylococcus aureus, Escherichia coli and Salmonella typhimurium populations in the ground chicken breast. Mean radiation D values determined for Staphylococcus aureus and Escherichia coli were 0.41 and 0.72 kGy, respectively. Gamma irradiation was an effective treatment for chicken meat conservation because the radiation dose of 6.0 kGy kept the ground chicken breast within the microbiological limits established by the Brazilian legislation for up to 28 days under refrigeration. (author)

  8. Effect of refrigeration time on the lipid oxidation and fatty acid profiles of catfish (Arius maculatus) commercialized in Cameroon

    International Nuclear Information System (INIS)

    Tenyang, N.; Womeni, H.M.; Tiencheu, B.; Villeneuve, P.; Linder, M.

    2017-01-01

    The effects of refrigeration at 4 °C during 9 days on the quality and stability of catfish oil were evaluated using a change in fatty acid composition by gas chromatography (GC), commonly used analytical indexes (acid and peroxide values), and analysis by Fourier transform infrared (FTIR) spectroscopy. The results revealed that lipid deterioration, hydrolysis and oxidation occurred throughout the cold storage (4 °C). Refrigeration induced the lipolysis of triglycerides by lipases and phospholipases. It also affected the fatty acids composition of the catfish. The progressive loss of unsaturation was monitored by the decrease in the absorbance band at 3012 cm−1on FTIR spectra and the lowest value was observed in the catfish muscle at 9 days of refrigeration. Eicosapentaenoic C20:5ω3 (EPA) and docosahexaenoic C22:6ω3 (DHA) acids were the polyunsaturated fatty acids most affected during refrigeration. Refrigeration for less than 5 days was found to be the best conditions for the preservation of the catfish. [es

  9. Effect of thiabendazole and packing materials on kinnow mandarin during storage

    International Nuclear Information System (INIS)

    Farooqi, W.A.; Ahmad, Maqbool; Hussain, A.M.; Qureshi, M.J.

    1975-01-01

    Effects of thiabendazole and some packing materials (tissue paper, wax paper and polyethylene film) on the shelf-life of Kinnow mandarins during storage at refrigerated and non-refrigerated temperatures were studied. Physiological, and organoleptic characteristics; control of fruit-rot in treated and untreated fruits and residual effect of thiabendazole in the peel and pulp of treated fruits are reported

  10. Effect of thiabendazole and packing materials on kinnow mandarin during storage

    Energy Technology Data Exchange (ETDEWEB)

    Farooqi, W A; Ahmad, Maqbool; Hussain, A M; Qureshi, M J

    1975-01-01

    Effects of thiabendazole and some packing materials (tissue paper, wax paper and polyethylene film) on the shelf-life of Kinnow mandarins during storage at refrigerated and non-refrigerated temperatures were studied. Physiological, and organoleptic characteristics; control of fruit-rot in treated and untreated fruits and residual effect of thiabendazole in the peel and pulp of treated fruits are reported.

  11. VARIATION IN PHYSICO-CHEMICAL PARAMETERS OF PROBIOTIC YOGURT DURING REFRIGERATION STORAGE

    OpenAIRE

    Flavia Pop; Anca Marinescu

    2009-01-01

    The obtained products (clasic and probiotic yogurt) were analyzed under the following aspects: organoleptic characteristics: clot appearance, aroma and taste and physicochemical characteristics: acidity, pH, fat, dry matter, ash. At the end of the analyzed period classic yogurt had an acidity of 166°T, with 9°T more than in the first day so the rate of acidity increase was 0.31°T/day during refrigeration and probiotic yogurt had an acidity of 177°T, with 12°T more than in the first day so the...

  12. Fuelcell-Hybrid Mine loader (LHD)

    Energy Technology Data Exchange (ETDEWEB)

    James L Dippo; Tim Erikson; Kris Hess

    2009-07-10

    The fuel cell hybrid mine loader project, sponsored by a government-industry consortium, was implemented to determine the viability of proton exchange membrane (PEM) fuel cells in underground mining applications. The Department of Energy (DOE) sponsored this project with cost-share support from industry. The project had three main goals: (1) to develop a mine loader powered by a fuel cell, (2) to develop associated metal-hydride storage and refueling systems, and (3) to demonstrate the fuel cell hybrid loader in an underground mine in Nevada. The investigation of a zero-emissions fuel cell power plant, the safe storage of hydrogen, worker health advantages (over the negative health effects associated with exposure to diesel emissions), and lower operating costs are all key objectives for this project.

  13. CONSERVATION OF THE VIABILITY AND VIGOR OF Araucaria angustifolia (Bert. O. Kuntze SEEDS DURING THE STORAGE

    Directory of Open Access Journals (Sweden)

    Cristhyane Garcia

    2014-12-01

    Full Text Available The conservation of Araucaria seeds is widely compromised in function of their recalcitrant feature, which hampers the planning of recovery actions of the degraded populations. Therefore, the objective of this study was to monitor the physiological changes in Araucaria seeds under controlled storage conditions, in order to get insights as to the viability and vigor conservation. The physiological quality of freshly harvested seeds was evaluated and every 60 days throughout the 180 days-storage period in laboratory ambient without thermal control, refrigerator (5 ° C, and freezer (-18 ° C until the final period of 180 days. After each sampling period, the seed viability (germination and tetrazolium tests and vigor (artificial aging, germination speed index – IVG and electrical conductivity were assessed. A reduction in the normal seedlings percentage was noticed over the period of storage of Araucaria seeds. The conservation in freezer and the lack of thermal control caused a complete loss of the seed viability at 60 and 180 days of storage, respectively. However, the refrigerator storage promoted the conservation of seed viability, with 64% germination after 180 days of storage, an event associated with the reduction of the metabolic activity of seeds. Based on the viability and vigor tests, it was concluded that storage in refrigerator provided longer storage periods to Araucaria seeds in comparison to the other storage conditions herein studied.

  14. Economic Operation of Supercritical CO2 Refrigeration Energy Storage Technology

    Science.gov (United States)

    Hay, Ryan

    With increasing penetration of intermittent renewable energy resources, improved methods of energy storage are becoming a crucial stepping stone in the path toward a smarter, greener grid. SuperCritical Technologies is a company based in Bremerton, WA that is developing a storage technology that can operate entirely on waste heat, a resource that is otherwise dispelled into the environment. The following research models this storage technology in several electricity spot markets around the US to determine if it is economically viable. A modification to the storage dispatch scheme is then presented which allows the storage unit to increase its profit in real-time markets by taking advantage of extreme price fluctuations. Next, the technology is modeled in combination with an industrial load profile on two different utility rate schedules to determine potential cost savings. The forecast of facility load has a significant impact on savings from the storage dispatch, so an exploration into this relationship is then presented.

  15. Development of the Consumer Refrigerator Safety Questionnaire: A Measure of Consumer Perceptions and Practices.

    Science.gov (United States)

    Cairnduff, Victoria; Dean, Moira; Koidis, Anastasios

    2016-09-01

    Food preparation and storage behaviors in the home deviating from the "best practice" food safety recommendations may result in foodborne illnesses. Currently, there are limited tools available to fully evaluate the consumer knowledge, perceptions, and behavior in the area of refrigerator safety. The current study aimed to develop a valid and reliable tool in the form of a questionnaire, the Consumer Refrigerator Safety Questionnaire (CRSQ), for assessing systematically all these aspects. Items relating to refrigerator safety knowledge (n =17), perceptions (n =46), and reported behavior (n =30) were developed and pilot tested by an expert reference group and various consumer groups to assess face and content validity (n =20), item difficulty and consistency (n =55), and construct validity (n =23). The findings showed that the CRSQ has acceptable face and content validity with acceptable levels of item difficulty. Item consistency was observed for 12 of 15 in refrigerator safety knowledge. Further, all 5 of the subscales of consumer perceptions of refrigerator safety practices relating to risk of developing foodborne disease showed acceptable internal consistency (Cronbach's α value > 0.8). Construct validity of the CRSQ was shown to be very good (P = 0.022). The CRSQ exhibited acceptable test-retest reliability at 14 days with the majority of knowledge items (93.3%) and reported behavior items (96.4%) having correlation coefficients of greater than 0.70. Overall, the CRSQ was deemed valid and reliable in assessing refrigerator safety knowledge and behavior; therefore, it has the potential for future use in identifying groups of individuals at increased risk of deviating from recommended refrigerator safety practices, as well as the assessment of refrigerator safety knowledge and behavior for use before and after an intervention.

  16. Grocery chains opt for green refrigeration. Renaissance of natural refrigerants; Lebensmittelketten entscheiden sich fuer gruene Kaeltetechnik. Renaissance der natuerlichen Kaeltemittel

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, Wolfgang

    2011-01-15

    Faster than expected the large German grocery chains focus on energy efficiency and sustainability. Due to the continuous growth in demand for 'Greens coldness' the component manufacturers expanded their portfolios especially for applications within the range of natural refrigerants. The general tendency on the Chillventa 2010 (Nuernberg, Federal Republic of Germany): More system engineering and a continuous growth in offer at trade-spanning all-in-one conceptions.

  17. Thermodynamic performance of an auto-cascade ejector refrigeration cycle with mixed refrigerant R32 + R236fa

    International Nuclear Information System (INIS)

    Tan, Yingying; Wang, Lin; Liang, Kunfeng

    2015-01-01

    In this paper, an auto-cascade ejector refrigeration cycle (ACERC) is proposed to obtain lower refrigeration temperature based on conventional ejector refrigeration and auto-cascade refrigeration principle. The thermodynamic performance of ACERC is investigated theoretically. The zeotropic refrigerant mixture R32 + R236fa is used as its working fluid. A parametric analysis is conducted to evaluate the effects of some thermodynamic parameters on the cycle performance. The study shows that refrigerant mixture composition, condenser outlet temperature and evaporation pressure have effects on performance of ACERC. The theoretical results also indicate that the ACERC can achieve the lowest refrigeration temperature at the temperature level of −30 °C. The application of zeotropic refrigerant mixture auto-cascade refrigeration in the ejector refrigeration cycle can provide a new way to obtain lower refrigeration temperature utilizing low-grade thermal energy. - Highlights: • An auto-cascade ejector refrigerator with R32 + R236fa mixed refrigerant is proposed. • The cycle can obtain a refrigeration temperature at −30 °C temperature range. • The effects of some thermodynamic parameters on the cycle performance are evaluated

  18. Antenna data storage concept for phased array radio astronomical instruments

    Science.gov (United States)

    Gunst, André W.; Kruithof, Gert H.

    2018-04-01

    Low frequency Radio Astronomy instruments like LOFAR and SKA-LOW use arrays of dipole antennas for the collection of radio signals from the sky. Due to the large number of antennas involved, the total data rate produced by all the antennas is enormous. Storage of the antenna data is both economically and technologically infeasible using the current state of the art storage technology. Therefore, real-time processing of the antenna voltage data using beam forming and correlation is applied to achieve a data reduction throughout the signal chain. However, most science could equally well be performed using an archive of raw antenna voltage data coming straight from the A/D converters instead of capturing and processing the antenna data in real time over and over again. Trends on storage and computing technology make such an approach feasible on a time scale of approximately 10 years. The benefits of such a system approach are more science output and a higher flexibility with respect to the science operations. In this paper we present a radically new system concept for a radio telescope based on storage of raw antenna data. LOFAR is used as an example for such a future instrument.

  19. High Efficiency, Low Emission Refrigeration System

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, Brian A [ORNL; Sharma, Vishaldeep [ORNL

    2016-08-01

    Supermarket refrigeration systems account for approximately 50% of supermarket energy use, placing this class of equipment among the highest energy consumers in the commercial building domain. In addition, the commonly used refrigeration system in supermarket applications is the multiplex direct expansion (DX) system, which is prone to refrigerant leaks due to its long lengths of refrigerant piping. This leakage reduces the efficiency of the system and increases the impact of the system on the environment. The high Global Warming Potential (GWP) of the hydrofluorocarbon (HFC) refrigerants commonly used in these systems, coupled with the large refrigerant charge and the high refrigerant leakage rates leads to significant direct emissions of greenhouse gases into the atmosphere. Methods for reducing refrigerant leakage and energy consumption are available, but underutilized. Further work needs to be done to reduce costs of advanced system designs to improve market utilization. In addition, refrigeration system retrofits that result in reduced energy consumption are needed since the majority of applications address retrofits rather than new stores. The retrofit market is also of most concern since it involves large-volume refrigerant systems with high leak rates. Finally, alternative refrigerants for new and retrofit applications are needed to reduce emissions and reduce the impact on the environment. The objective of this Collaborative Research and Development Agreement (CRADA) between the Oak Ridge National Laboratory and Hill Phoenix is to develop a supermarket refrigeration system that reduces greenhouse gas emissions and has 25 to 30 percent lower energy consumption than existing systems. The outcomes of this project will include the design of a low emission, high efficiency commercial refrigeration system suitable for use in current U.S. supermarkets. In addition, a prototype low emission, high efficiency supermarket refrigeration system will be produced for

  20. Short communication: survival of the characteristic microbiota in probiotic fermented camel, cow, goat, and sheep milks during refrigerated storage.

    Science.gov (United States)

    Varga, L; Süle, J; Nagy, P

    2014-01-01

    The objective of this study was to monitor the viability during storage of Lactobacillus acidophilus LA-5 (A), Bifidobacterium animalis ssp. lactis BB-12 (B), and Streptococcus thermophilus CHCC 742/2130 (T) in probiotic cultured dairy foods made from pasteurized camel, cow, goat, and sheep milks fermented by an ABT-type culture. The products manufactured were stored at 4°C for 42d. Microbiological analyses were performed at weekly intervals. Streptococcus thermophilus CHCC 742/2130 was the most numerous culture component in all 4 products both at the beginning and at the end of storage. The viable counts of streptococci showed no significant decline in fermented camel milk throughout the entire storage period. The initial numbers of Lb. acidophilus LA-5 were over 2 orders of magnitude lower than those of Strep. thermophilus CHCC 742/2130. With the progress of time, a slow and constant decrease was observed in lactobacilli counts; however, the final viability percentages of this organism did not differ significantly in the probiotic fermented milks tested. The cultured dairy foods made from cow, sheep, and goat milks had comparable B. animalis ssp. lactis BB-12 counts on d 0, exceeding by approximately 0.5 log10 cycle those in the camel milk-based product. No significant losses occurred in viability of bifidobacteria in fermented camel, cow, and sheep milks during 6wk of refrigerated storage. In conclusion, all 4 varieties of milk proved to be suitable raw materials for the manufacture of ABT-type fermented dairy products that were microbiologically safe and beneficial for human consumption. It was suggested that milk from small ruminants be increasingly used to produce probiotic fermented dairy foods. The development of camel milk-based probiotic cultured milks appears to be even more promising because new markets could thus be conquered. It must be emphasized, however, that further microbiological and sensory studies, technology development activities, and

  1. Mines as lower reservoir of an UPSH (Underground Pumping Storage Hydroelectricity): groundwater impacts and feasibility

    Science.gov (United States)

    Bodeux, Sarah; Pujades, Estanislao; Orban, Philippe; Dassargues, Alain

    2016-04-01

    The energy framework is currently characterized by an expanding use of renewable sources. However, their intermittence could not afford a stable production according to the energy demand. Pumped Storage Hydroelectricity (PSH) is an efficient possibility to store and release electricity according to the demand needs. Because of the topographic and environmental constraints of classical PSH, new potential suitable sites are rare in countries whose topography is weak or with a high population density. Nevertheless, an innovative alternative is to construct Underground Pumped Storage Hydroelectricity (UPSH) plants by using old underground mine works as lower reservoir. In that configuration, large amount of pumped or injected water in the underground cavities would impact the groundwater system. A representative UPSH facility is used to numerically determine the interactions with surrounding aquifers Different scenarios with varying parameters (hydrogeological and lower reservoir characteristics, boundaries conditions and pumping/injection time-sequence) are computed. Analysis of the computed piezometric heads around the reservoir allows assessing the magnitude of aquifer response and the required time to achieve a mean pseudo-steady state under cyclic solicitations. The efficiency of the plant is also evaluated taking the leakage into the cavity into account. Combining these two outcomes, some criterions are identified to assess the feasibility of this type of projects within potential old mine sites from a hydrogeological point of view.

  2. Pharmspresso: a text mining tool for extraction of pharmacogenomic concepts and relationships from full text.

    Science.gov (United States)

    Garten, Yael; Altman, Russ B

    2009-02-05

    Pharmacogenomics studies the relationship between genetic variation and the variation in drug response phenotypes. The field is rapidly gaining importance: it promises drugs targeted to particular subpopulations based on genetic background. The pharmacogenomics literature has expanded rapidly, but is dispersed in many journals. It is challenging, therefore, to identify important associations between drugs and molecular entities--particularly genes and gene variants, and thus these critical connections are often lost. Text mining techniques can allow us to convert the free-style text to a computable, searchable format in which pharmacogenomic concepts (such as genes, drugs, polymorphisms, and diseases) are identified, and important links between these concepts are recorded. Availability of full text articles as input into text mining engines is key, as literature abstracts often do not contain sufficient information to identify these pharmacogenomic associations. Thus, building on a tool called Textpresso, we have created the Pharmspresso tool to assist in identifying important pharmacogenomic facts in full text articles. Pharmspresso parses text to find references to human genes, polymorphisms, drugs and diseases and their relationships. It presents these as a series of marked-up text fragments, in which key concepts are visually highlighted. To evaluate Pharmspresso, we used a gold standard of 45 human-curated articles. Pharmspresso identified 78%, 61%, and 74% of target gene, polymorphism, and drug concepts, respectively. Pharmspresso is a text analysis tool that extracts pharmacogenomic concepts from the literature automatically and thus captures our current understanding of gene-drug interactions in a computable form. We have made Pharmspresso available at http://pharmspresso.stanford.edu.

  3. Variation in content of macronutrients of guava tree leaves, in function of type and time of storage

    Directory of Open Access Journals (Sweden)

    Henrique Antunes de Souza

    2010-10-01

    Full Text Available Leaf analysis for perennial crops such as the guava tree is an important tool. It was used to evaluate the influence of the type of packaging (with or without refrigerator and storage time after collection on the macronutrient composition of guava tree leaves. The leaf sampling was carried out on a commercial guava tree (cv. Paluma, collecting the third pair of recently matured leaves in full bloom. The experimental design was in randomized blocks, subdivided according to the type of packaging (with or without refrigerator and further subdivided into eight storage times before washing (zero, 6, 12, 24, 48, 72, 96 and 168h after sampling, with four replications. The storage time significantly affected the concentration of leaf nitrogen, calcium and sulfur. Moreover, the type and time of conditioning (with or without refrigerator affected only the magnesium. In general, storage fot up to 12h before washing produced no significant changes in the levels of macronutrients.

  4. Variation in content of macronutrients of guava tree leaves, in function of type and time of storage

    Directory of Open Access Journals (Sweden)

    Henrique Antunes de Souza

    2010-09-01

    Full Text Available Leaf analysis for perennial crops such as the guava tree is an important tool. It was used to evaluate the influence of the type of packaging (with or without refrigerator and storage time after collection on the macronutrient composition of guava tree leaves. The leaf sampling was carried out on a commercial guava tree (cv. Paluma, collecting the third pair of recently matured leaves in full bloom. The experimental design was in randomized blocks, subdivided according to the type of packaging (with or without refrigerator and further subdivided into eight storage times before washing (zero, 6, 12, 24, 48, 72, 96 and 168h after sampling, with four replications. The storage time significantly affected the concentration of leaf nitrogen, calcium and sulfur. Moreover, the type and time of conditioning (with or without refrigerator affected only the magnesium. In general, storage fot up to 12h before washing produced no significant changes in the levels of macronutrients.

  5. Low Temperature Refrigeration as an Alternative Anti-Pest Treatment of Dates

    Science.gov (United States)

    Lallouche, Ahmed; Kolodyaznaya, Valentina; Boulkrane, Mohamed Said; Baranenko, Denis

    2017-11-01

    Large amounts of dates are produced and consumed around the world each year. Apomyelois ceratoniae causes main losses during storage and export of date fruit. Fumigation is the most widely used treatment to prevent postharvest losses. However, this treatment negatively affects the biological value of dates, environmental and economic parameters of production. Widespread fumigation agent methyl bromide is toxic to a human body and contributes to the destruction of the ozone layer. The aim of the current work was to find a new method based on the use of low temperature refrigeration to reduce the pest and insect infestation preserving the nutritive value of dates during cold storage at the same time. A. ceratoniae mortality under different temperatures and dates respiration rate, sugar, organic acids, pectic substances content and sensorial characteristics were studied. The results indicate that at -18 °C the A. ceratonie larva dies within 2 h, the eggs and larvae - within 24 h respectively. Thus, it is clearly shown that there is no need in using chemicals or irradiation to prevent dates pests. Physicochemical and organoleptic proprieties of dates were satisfactory during 360 d at -18 °C and during 180 d at +4 °C. The low temperature refrigeration and storage at -18 °C is recommended for dates to prevent pests and quality losses. It is apparently advantageous for environment and climate if compared with other anti-pest treatment variants.

  6. Potential of carboxymethyl cellulose coating and low dose gamma irradiation to maintain storage quality, inhibit fungal growth and extend shelf-life of cherry fruit.

    Science.gov (United States)

    Hussain, P R; Rather, S A; Suradkar, P; Parveen, S; Mir, M A; Shafi, F

    2016-07-01

    Carboxymethyl cellulose (CMC) coatings alone and in combination with gamma irradiation was tested for maintaining the storage quality, inhibiting fungal incidence and extending shelf-life of cherry fruit. Two commercial cherry varieties viz. Misri and Double after harvest at commercial maturity were coated with CMC at levels 0.5-1.0 % w/v and gamma irradiated at 1.2 kGy. The treated fruit including control was stored under ambient (temperature 25 ± 2 °C, RH 70 %) and refrigerated (temperature 3 ± 1 °C, RH 80 %) conditions for evaluation of various physico-chemical parameters. Fruits were evaluated after every 3 and 7 days under ambient and refrigerated conditions. CMC coating alone at levels 0.5 and 0.75 % w/v was not found effective with respect to mold growth inhibition under either of the two conditions. Individual treatment of CMC coating at 1.0 % w/v and 1.2 kGy irradiation proved helpful in delaying the onset of mold growth up to 5 and 8 days of ambient storage. During post-refrigerated storage at 25 ± 2 °C, RH 70 %, irradiation alone at 1.2 kGy gave further 4 days extension in shelf-life of cherry varieties following 28 days of refrigeration. All combinatory treatments of CMC coating and irradiation proved beneficial in maintaining the storage quality as well as delaying the decaying of cherry fruit during post-refrigerated storage at 25 ± 2 °C, RH 70 % but, combination of CMC at 1.0 % w/v and 1.2 kGy irradiation was found significantly ( p  ≤ 0.05) superior to all other treatments in maintaining the storage quality and delaying the decaying of cherry fruit. The above combinatory treatment besides maintaining storage quality resulted in extension of 6 days in shelf life of cherry varieties during post-refrigerated storage at 25 ± 2 °C, RH 80 % following 28 days of refrigeration. Above Combination treatment gave a maximum of 2.3 and 1.5 log reduction in yeast and mold count of cherry fruits after 9 and 28

  7. Design and component test performance of an efficient 4 W, 130 K sorption refrigerator

    International Nuclear Information System (INIS)

    Alvarez, J.; Ryba, E.; Sywulka, P.; Wade, L.

    1990-01-01

    A recent advance in sorption cooler technology has resulted in cryocooler designs offering high performance and the promise of long-life operation. A 4-W, 130 K sorption refrigeration stage which incorporates the advanced concept design is presently being constructed. Powdered charcoal is used as the sorbent, and methane is used as the refrigerant. Expansion is accomplished using a passive Joule-Thomson expansion valve. The design details of this cooler and the component performance test results are discussed. 5 refs

  8. 10 CFR 431.62 - Definitions concerning commercial refrigerators, freezers and refrigerator-freezers.

    Science.gov (United States)

    2010-01-01

    ... functional characteristics that affect energy consumption. Commercial refrigerator, freezer, and refrigerator... formed by the plane of the door, when the equipment is viewed in cross-section; and (2) For equipment...

  9. Assessment and study of existing concepts and methods of cryogenic refrigeration for superconducting transmission cables. Final report. Draft

    International Nuclear Information System (INIS)

    Kadi, F.J.; Longsworth, R.C.

    1976-02-01

    A review of current programs to develop superconducting power transmission shows that current plans require helium refrigerators operating at 5 to 13 0 K and 3 to 15 atm pressure with compressor power input in the range of 1300 to 3500 HP. Future requirements will probably trend towards slightly higher temperatures and larger refrigerators. Present large helium refrigerators and APCI standard nitrogen plants were studied and average outage frequency of about 18 per year is found to be typical for both. Cost and reliability studies of alternate refrigeration systems based on studies of components shows that the best current system which would have a failure rate of once in 20 y would consist of two full size oil flooded screw compressors in parallel, manifolded to two full size cold boxes and a liquid helium back up dewar. The principal area of development needed to implement this system is in the switch over mechanisms. These include switching to an auxillary power source in the event of power interruption, switching to the standby compressor, and switching to the back up liquid helium dewar. Costs are projected as being only slightly greater than preliminary estimates

  10. Legacy sediment, lead, and zinc storage in channel and floodplain deposits of the Big River, Old Lead Belt Mining District, Missouri, USA

    Science.gov (United States)

    Pavlowsky, Robert T.; Lecce, Scott A.; Owen, Marc R.; Martin, Derek J.

    2017-12-01

    The Old Lead Belt of southeastern Missouri was one of the leading producers of Pb ore for more than a century (1869-1972). Large quantities of contaminated mine waste have been, and continue to be, supplied to local streams. This study assessed the magnitude and spatial distribution of mining-contaminated legacy sediment stored in channel and floodplain deposits of the Big River in the Ozark Highlands of southeastern Missouri. Although metal concentrations decline downstream from the mine sources, the channel and floodplain sediments are contaminated above background levels with Pb and Zn along its entire 171-km length below the mine sources. Mean concentrations in floodplain cores > 2000 mg kg- 1 for Pb and > 1000 mg kg- 1 for Zn extend 40-50 km downstream from the mining area in association with the supply of fine tailings particles that were easily dispersed downstream in the suspended load. Mean concentrations in channel bed and bar sediments ranging from 1400 to 1700 mg kg- 1 for Pb extend 30 km below the mines, while Zn concentrations of 1000-3000 mg kg- 1 extend 20 km downstream. Coarse dolomite fragments in the 2-16 mm channel sediment fraction provide significant storage of Pb and Zn, representing 13-20% of the bulk sediment storage mass in the channel and can contain concentrations of > 4000 mg kg- 1 for Pb and > 1000 mg kg- 1 for Zn. These coarse tailings have been transported a maximum distance of only about 30 km from the source over a period of 120 years for an average of about 250 m/y. About 37% of the Pb and 9% of the Zn that was originally released to the watershed in tailings wastes is still stored in the Big River. A total of 157 million Mg of contaminated sediment is stored along the Big River, with 92% of it located in floodplain deposits that are typically contaminated to depths of 1.5-3.5 m. These contaminated sediments store a total of 188,549 Mg of Pb and 34,299 Mg of Zn, of which 98% of the Pb and 95% of the Zn are stored in floodplain

  11. Efficiency of irradiation as alternative or supplementary technique to the refrigeration in mango

    International Nuclear Information System (INIS)

    1987-11-01

    The behaviour of mango cultivar Keitt was studied concerning to its preservation when submitted to irradiation of 80 Krad, storage at media environmental temperature of 21 0 C and air relative humidity at 83% and under refrigeration at 12 0 C with air relative humidity at 90%. The results shown that irradiated mangoes storage at 12 0 C were in good conditions after four weeks with low rate of anthraquinosis and media texture of 1,1 Kg/cm 2 and the control presented ),05 Kg/cm 2 . (L.M.J.)

  12. Preservation by ionization of refrigerated vacuum-packed ground beef

    International Nuclear Information System (INIS)

    Soualhia, Z.

    1998-01-01

    The application of doses of 1, 2, 3, 4, 5 KGy is interesting to lower significantly the contamination microbial flora in ground beef without changing significantly for all that original qualities. Treatment combining ionization (5 KGy) and / or salting (2 %) increases of almost 2 months the duration of refrigerated conservation of Vacuum-packed ground beef with no major change in initial quality. In ionized beef (5 KGy) and / or salted (2 %), the rate of psychotropic germs stays inferior to the threshold superficial putrefaction at all conservation stages. Moreover, faecal contamination pilots, mouldiness, yeast and pathogenic micro-organisms are totally absent in treated samples. Reduction effect of salt is observed at all stages of refrigerated storage. Finally, after cooking, ionizing dose does not change significantly loss of weight and pH of ground beef heated at 100 degrees C in bain-marie or 150 degrees C in drying over during one hour (author)

  13. The dynamic single-tube concept; Le mono-tube dynamique

    Energy Technology Data Exchange (ETDEWEB)

    Rivet, P. [Ste MC International (France)

    1997-12-31

    In the framework of greenhouse gas emission reduction and the utilization of cooling intermediate fluids with indirect refrigerating systems, a new concept of dynamical single-tube has been developed, which allows for the simultaneous cold distribution from a centralized plant towards various required temperature systems (as for example in a supermarket refrigerating system) with optimized efficiency, fluid flow and defrosting conditions; moreover, the dynamic single-tube concept is very well adapted to two-phase flows

  14. Research and development of utilization technology of solar thermal system for industrial and other use. Development of system of advanced heat process type (chemical refrigeration and cold storage system using solar heat); Sangyoyo nado solar system jitsuyoka gijutsu kaihatsu. Advanced heat process gata system no kaihatsu (taiyonetsu reito reizo no kaihatsu)

    Energy Technology Data Exchange (ETDEWEB)

    Takita, M [New Energy and Industrial Technology Development Organization, Tokyo (Japan)

    1994-12-01

    Described herein are the results of the FY1994 research program for chemical refrigeration and cold storage system using solar heat. The study on refrigeration materials are aimed at development of new hydrogen-occluding alloys which show good hydrogenation equilibrium characteristics and reactivity at temperature required for stand-alone refrigeration systems aided by solar heat, and still new hydrogen-occluding alloys operable at refrigeration temperature for lower-temperature systems. For the refrigeration materials capable of producing low-temperature heat of -10{degree}C at a regeneration temperature of 140{degree}C produced by solar heat, a La-Ni-Mn-Al alloy is selected for high-temperature use and a La-Y-Ni-Mn alloy for low-temperature use. The study on technology for refrigeration modules develops high-efficiency heat exchangers for refrigeration and regeneration, compatible with the hydrogen-occluding alloys. It also develops air-and water-cooling techniques for hydrogen-occluding alloys, where air is used as the heat source. The test apparatus is designed, installed and operated, to attain a low temperature of -10{degree}C or lower with a heat source of 140{degree}C and air heat source of 28{degree}C. 7 figs.

  15. IEA SHC Task 38 'Solar air-conditioning and refrigeration'. Danish participation 2007-2010. Appendix; IEA SHC Task 38 'Solar air-conditioning and refrigeration'. Dansk deltagelse 2007-2010. Bilag

    Energy Technology Data Exchange (ETDEWEB)

    Ellehauge, K. (Ellehauge og Kildemoes, Aarhus (Denmark)); Muenster, E. (PlanEnergi, Skoerping (Denmark)); Reinholdt, L. (Teknologisk Institut, Aarhus (Denmark)); Munds, S. (AC-Sun Aps, Horsens (Denmark))

    2011-03-15

    IEA SHC Task 38 'Solar Air-Conditioning and Refrigeration' ran from October 2006 to December 2010. Denmark was represented in the task from January 2007 to December 2010. The aim of the task was to encourage use of solar powered refrigeration and air conditioning systems in particular at residential, commercial and industrial sectors. Furthermore, the aim was to contribute to new research and development activities on new systems and concepts. The appendix contains the publications prepared by the Danish project group.(LN)

  16. Unconventional energy resources in a crowded subsurface: Reducing uncertainty and developing a separation zone concept for resource estimation and deep 3D subsurface planning using legacy mining data.

    Science.gov (United States)

    Monaghan, Alison A

    2017-12-01

    Over significant areas of the UK and western Europe, anthropogenic alteration of the subsurface by mining of coal has occurred beneath highly populated areas which are now considering a multiplicity of 'low carbon' unconventional energy resources including shale gas and oil, coal bed methane, geothermal energy and energy storage. To enable decision making on the 3D planning, licensing and extraction of these resources requires reduced uncertainty around complex geology and hydrogeological and geomechanical processes. An exemplar from the Carboniferous of central Scotland, UK, illustrates how, in areas lacking hydrocarbon well production data and 3D seismic surveys, legacy coal mine plans and associated boreholes provide valuable data that can be used to reduce the uncertainty around geometry and faulting of subsurface energy resources. However, legacy coal mines also limit unconventional resource volumes since mines and associated shafts alter the stress and hydrogeochemical state of the subsurface, commonly forming pathways to the surface. To reduce the risk of subsurface connections between energy resources, an example of an adapted methodology is described for shale gas/oil resource estimation to include a vertical separation or 'stand-off' zone between the deepest mine workings, to ensure the hydraulic fracturing required for shale resource production would not intersect legacy coal mines. Whilst the size of such separation zones requires further work, developing the concept of 3D spatial separation and planning is key to utilising the crowded subsurface energy system, whilst mitigating against resource sterilisation and environmental impacts, and could play a role in positively informing public and policy debate. Copyright © 2017 British Geological Survey, a component institute of NERC. Published by Elsevier B.V. All rights reserved.

  17. Effect of Oven Types on the Characteristics of Biscuits Made from Refrigerated and Frozen Doughs

    Directory of Open Access Journals (Sweden)

    Ismail Sait Dogan

    2006-01-01

    Full Text Available Characteristics of sugar snap and chocolate chip cookies, and hazelnut biscuits made from refrigerated and frozen dough were studied. Doughs were stored at 4 °C for 6 weeks and at –18 °C for 6 months, respectively. Physical characteristics of the biscuit samples such as spread, baking loss, surface colour and density were determined. Dough colour was not affected by storage time and temperatures. Biscuit characteristics did not change significantly during storage. Spread ratio was significantly lower for the biscuits baked in the gas oven than for the biscuits baked in the electric oven. Biscuit dough can be refrigerated for 6 weeks, and frozen for 6 months. Results also suggest that unique quality differences exist between the two ovens. For sugar snap cookies and hazelnut biscuits the electric oven without air circulation was better, while for chocolate chip cookies gas oven with air circulation was more suitable.

  18. Alternative design concept for the second Glass Waste Storage Building

    International Nuclear Information System (INIS)

    Rainisch, R.

    1992-10-01

    This document presents an alternative design concept for storing canisters filled with vitrified waste produced at the Defense Waste Processing Facility (DWPF). The existing Glass Waste Storage Building (GWSB1) has the capacity to store 2,262 canisters and is projected to be completely filled by the year 2000. Current plans for glass waste storage are based on constructing a second Glass Waste Storage Building (GWSB2) once the existing Glass Waste Storage Building (GWSB1) is filled to capacity. The GWSB2 project (Project S-2045) is to provide additional storage capacity for 2,262 canisters. This project was initiated with the issue of a basic data report on March 6, 1989. In response to the basic data report Bechtel National, Inc. (BNI) prepared a draft conceptual design report (CDR) for the GWSB2 project in April 1991. In May 1991 WSRC Systems Engineering issued a revised Functional Design Criteria (FDC), the Rev. I document has not yet been approved by DOE. This document proposes an alternative design for the conceptual design (CDR) completed in April 1991. In June 1992 Project Management Department authorized Systems Engineering to further develop the proposed alternative design. The proposed facility will have a storage capacity for 2,268 canisters and will meet DWPF interim storage requirements for a five-year period. This document contains: a description of the proposed facility; a cost estimate of the proposed design; a cost comparison between the proposed facility and the design outlined in the FDC/CDR; and an overall assessment of the alternative design as compared with the reference FDC/CDR design

  19. Design, Fabrication, Installation and Commissioning of the Helium Refrigeration system Supporting Superconducting Radio Frequency Testing at Facility for Rare Isotope Beams at Michigan State University

    Science.gov (United States)

    Casagrande, F.; Fila, A.; Nguyen, C.; Tatsumoto, H.

    2017-12-01

    The Facility for Rare Isotope Beams (FRIB) will be a scientific user facility for the Office of Nuclear Physics in the U.S. Department of Energy Office of Science (DOE-SC). The FRIB linear accelerator (LINAC) will be comprised of cryomodules each with multiple Superconducting Radio Frequency (SRF) cavities operating at 2 K. A helium refrigeration system was designed, fabricated, installed and commissioned in the SRF high bay building to test and certify these cavities and cryomodules before installation in the FRIB LINAC tunnel. The helium refrigeration system includes a helium refrigerator which has nominal capacity of 900 W at 4 K, 5000 L liquid helium storage Dewar, helium gas storage, two room temperature vacuum pumps capable of 2.5 g/s each for 2 K testing, purifier, purifier recovery compressor, and the distribution system for liquid nitrogen and helium. The helium refrigeration system is now operational supporting three below grade cavity testing Dewars and one cryomodule testing bunker meeting the required throughput of 1 cavity per day.

  20. Long-term interim storage concepts with conditioning strategies ensuring compatibility with subsequent disposal or reprocessing

    International Nuclear Information System (INIS)

    Moitrier, C.; Tirel, I.; Villard, C.

    2000-01-01

    The objective of the CEA studies carried out under research topic 3 (long-term interim storage) of the 1991 French radioactive waste management law is to demonstrate the industrial feasibility of a comprehensive, flexible interim storage facility by thoroughly evaluating and comparing all the basic components of various interim storage concepts. In this context, the CEA is considering reference solutions or concepts based on three primary components (the package, the interim storage facility and the site) suitable for determining the specifications of a very long-term solution. Some aspects are examined in greater detail, such as the implementation of long-term technologies, conditioning processes ensuring the absence of water and contamination in the facility, or allowance for radioactive decay of the packages. The results obtained are continually compiled in reports substantiating the design options. These studies should also lead to an overall economic assessment in terms of the capital and operating cost requirements, thereby providing an additional basis for selecting the design options. The comparison with existing industrial facilities highlights the technical and economic progress represented by the new generation of interim storage units. (authors)

  1. Compact and energy-saving trickle film ice storage unit; Rieselfilm-Eisspeicheranlage baut kompakt und spart Energie

    Energy Technology Data Exchange (ETDEWEB)

    Pompetzki, F. [Zimmer Edelstahl GmbH, Nuernberg (Germany)

    1998-12-31

    Ice storages are well established in industrial refrigeration systems. The contribution describes new, compact trickle film ice storages with plate heat exchangers. These systems need less refrigerant and consume up to 30% less energy. (orig.) [Deutsch] Eisspeicher haben sich in der industriellen Kaeltetechnik seit langem bewaehrt. Neue Impulse erhaelt diese Technik jetzt durch kompakt aufgebaute Rieselfilm-Eisspeicher mit Plattenwaermeaustauscher. Aufgrund ihrer Konzeption benoetigen sie bei gleicher Leistung deutlich weniger Kaeltemittel und verbrauchen bis zu 30% weniger Energie. (orig.)

  2. Thermoelectric refrigerator having improved temperature stabilization means

    International Nuclear Information System (INIS)

    Falco, C.M.

    1982-01-01

    A control system for thermoelectric refrigerators is disclosed. The thermoelectric refrigerator includes at least one thermoelectric element that undergoes a first order change at a predetermined critical temperature. The element functions as a thermoelectric refrigerator element above the critical temperature, but discontinuously ceases to function as a thermoelectric refrigerator element below the critical temperature. One example of such an arrangement includes thermoelectric refrigerator elements which are superconductors. The transition temperature of one of the superconductor elements is selected as the temperature control point of the refrigerator. When the refrigerator attempts to cool below the point, the metals become superconductors losing their ability to perform as a thermoelectric refrigerator. An extremely accurate, first-order control is realized

  3. Environment-friendly refrigeration - Switzerland moves forward

    International Nuclear Information System (INIS)

    Stohler, F.

    2003-01-01

    This article presents an interview with Silvan Schaller, president of the Swiss Refrigeration Society SVK and head of a leading Swiss industrial refrigeration company, on the subject of the implementation of new Swiss materials legislation that regulates the use of various refrigerants. In particular, the co-operation between the Society and the regulatory authorities is stressed. The reasons behind the regulations - the protection of the environment and, in particular, the ozone layer - are discussed as are the efforts required by industry to meet them. Future refrigeration technologies and the choice of refrigerants are examined. Measures that will have to be taken by the companies in the refrigeration sector, such as the additional training of personnel and the monitoring of the disposal of wastes, are examined. For the future, the goal of reducing the energy consumption of refrigeration installations is noted

  4. Modelling and control of large cryogenic refrigerator

    International Nuclear Information System (INIS)

    Bonne, Francois

    2014-01-01

    This manuscript is concern with both the modeling and the derivation of control schemes for large cryogenic refrigerators. The particular case of those which are submitted to highly variable pulsed heat load is studied. A model of each object that normally compose a large cryo-refrigerator is proposed. The methodology to gather objects model into the model of a subsystem is presented. The manuscript also shows how to obtain a linear equivalent model of the subsystem. Based on the derived models, advances control scheme are proposed. Precisely, a linear quadratic controller for warm compression station working with both two and three pressures state is derived, and a predictive constrained one for the cold-box is obtained. The particularity of those control schemes is that they fit the computing and data storage capabilities of Programmable Logic Controllers (PLC) with are well used in industry. The open loop model prediction capability is assessed using experimental data. Developed control schemes are validated in simulation and experimentally on the 400W1.8K SBT's cryogenic test facility and on the CERN's LHC warm compression station. (author) [fr

  5. Fault diagnosis and refrigerant leak detection in vapour compression refrigeration systems

    Energy Technology Data Exchange (ETDEWEB)

    Tassou, S.A.; Grace, I.N. [Brunel University, Uxbridge (United Kingdom). Department of Mechanical Engineering

    2005-08-01

    The environmental impact of refrigeration systems can be reduced by operation at higher efficiency and reduction of refrigerant leakage. Refrigerant loss contributes both directly and indirectly to global warming through inefficient system operation, increased power consumption and greenhouse gas emissions and higher maintenance costs. Existing sensor-based leak detection methods are limited by the inability to detect gradual leakage and the need for careful sensor location. There is a requirement for a real-time performance monitoring approach to leak detection and fault diagnosis which overcomes these disadvantages. This paper reports on the development of a fault diagnosis and refrigerant leak detection system based on artificial intelligence and real-time performance monitoring. The system has been used successfully to distinguish between faulty and fault free operation, steady-state and transient operation, leakage and over charge conditions. Work currently underway is aimed at testing additional fault conditions and establishing further rules to distinguish between these patterns. (author)

  6. Factors affecting vaccine handling and storage practices among ...

    African Journals Online (AJOL)

    Objective: Assessing the factors associated with vaccine handling and storage practices. Methods: This was a .... Others include insufficient/unavailable backup refrigerators (52%) .... Human Vaccines 2010; 6(3): 270-278. 5. Joao Carlos de ...

  7. Regulating Power from Supermarket Refrigeration

    DEFF Research Database (Denmark)

    O'Connell, Niamh; Madsen, Henrik; Pinson, Pierre

    2014-01-01

    the Danfoss refrigeration test centre. The complexities of modelling demand response are demonstrated through simulation. Simulations are conducted by placing the identified model in a direct-control demand response architecture, with power reference tracking using model predictive control. The energylimited......This paper presents an analysis of the demand response capabilities of a supermarket refrigeration system, with a particular focus on the suitability for participation in the regulating power market. An ARMAX model of a supermarket refrigeration system is identified using experimental data from...... nature of demand response from refrigeration is identified as the key consideration when considering participation in the regulating power market. It is demonstrated that by restricting the operating regions of the supermarket refrigeration system, a simple relationship can be found between the available...

  8. Finite time thermodynamics of power and refrigeration cycles

    CERN Document Server

    Kaushik, Shubhash C; Kumar, Pramod

    2017-01-01

    This book addresses the concept and applications of Finite Time Thermodynamics to various thermal energy conversion systems including heat engines, heat pumps, and refrigeration and air-conditioning systems. The book is the first of its kind, presenting detailed analytical formulations for the design and optimisation of various power producing and cooling cycles including but not limited to: • Vapour power cycles • Gas power cycles • Vapour compression cycles • Vapour absorption cycles • Rankine cycle coupled refrigeration systems Further, the book addresses the thermoeconomic analysis for the optimisation of thermal cycles, an important field of study in the present age and which is characterised by multi-objective optimization regarding energy, ecology, the environment and economics. Lastly, the book provides the readers with key techniques associated with Finite Time Thermodynamics, allowing them to understand the relevance of irreversibilitie s associated with real processes and the scientific r...

  9. Concepts for the interim storage of spent fuel elements from research reactors in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Niephaus, D.; Bensch, D.; Quaassdorff, P.; Plaetzer, S.

    1997-01-01

    Research reactors have been operated in the Federal Republic of Germany since the late fifties. These are Material Test Reactors (MTR) and training, Research and Isotope Facilities of General Atomic (TRIGA). A total of seven research reactors, i.e. three TRIGA and four MTR facilities were still in operation at the beginning of 1996. Provisions to apply to the back-end of the fuel cycle are required for their continued operation and for already decommissioned plants. This was ensured until the end of the eighties by the reprocessing of spent fuel elements abroad. In view of impeding uncertainties in connection with waste management through reprocessing abroad, the development of a national back-end fuel cycle concept was commissioned by the Federal Minister of Education, Science, Research and Technology in early 1990. Development work was oriented along the lines of the disposal concept for irradiated light-water reactor fuel elements from nuclear power plants. Analogously, the fuel elements from research reactors are to be interim-stored on a long-term basis in adequately designed transport and storage casks and then be directly finally disposed without reprocessing after up to forty years of interim storage. As a first step in the development of a concept for interim storage, several sites with nuclear infrastructure were examined and assessed with respect to their suitability for interim storage. A reasonably feasible reference concept for storing the research reactor fuel elements in CASTOR MTR 2 transport and storage casks at the Ahaus interim storage facility (BZA) was evaluated and the hot cell facility and AVR store of Forschungszentrum Juelich (KFA) were proposed as an optional contingency concept for casks that cannot be repaired at Ahaus. Development work was continued with detailed studies on these two conceptual variants and the results are presented in this paper. (author)

  10. Transition to New Refrigerants

    Science.gov (United States)

    Overview page provides information on the refrigerants that motor vehicle air conditioners have used over time, with information on environmental impacts, refrigerant fitting sizes, label colors, and alternatives to ozone-depleting substances.

  11. Liquid neon heat intercept for superconducting energy storage magnets

    International Nuclear Information System (INIS)

    Khalil, A.; McIntosh, G.E.

    1982-01-01

    Previous analyses of heat intercept solutions are extended to include both insulation and strut heat leaks. The impact of using storable, boiling cryogens for heat intercept fluids, specifically liquid neon and nitrogen, is also examined. The selection of fluid for the heat intercepts is described. Refrigeration power for 1000 and 5000 MWhr SMES units is shown with optimum refrigeration power for each quantity shown in tables. Nitrogen and Neon cooled intercept location for minimum total refrigeration power for a 5000 MWhr SMES are each shown, as well as the location of nitrogen and neon cooled intercepts for minimum total refrigeration power for 5000 MWhr SMES. Cost comparisons are itemized and neon cost and availability discussed. For a large energy storage magnet system, liquid neon is a more effective heat intercept fluid than liquid nitrogen. Reasons and application of the conclusion are amplified

  12. Privacy Preserving Similarity Based Text Retrieval through Blind Storage

    Directory of Open Access Journals (Sweden)

    Pinki Kumari

    2016-09-01

    Full Text Available Cloud computing is improving rapidly due to their more advantage and more data owners give interest to outsource their data into cloud storage for centralize their data. As huge files stored in the cloud storage, there is need to implement the keyword based search process to data user. At the same time to protect the privacy of data, encryption techniques are used for sensitive data, that encryption is done before outsourcing data to cloud server. But it is critical to search results in encryption data. In this system we propose similarity text retrieval from the blind storage blocks with encryption format. This system provides more security because of blind storage system. In blind storage system data is stored randomly on cloud storage.  In Existing Data Owner cannot encrypt the document data as it was done only at server end. Everyone can access the data as there was no private key concept applied to maintained privacy of the data. But In our proposed system, Data Owner can encrypt the data himself using RSA algorithm.  RSA is a public key-cryptosystem and it is widely used for sensitive data storage over Internet. In our system we use Text mining process for identifying the index files of user documents. Before encryption we also use NLP (Nature Language Processing technique to identify the keyword synonyms of data owner document. Here text mining process examines text word by word and collect literal meaning beyond the words group that composes the sentence. Those words are examined in API of word net so that only equivalent words can be identified for index file use. Our proposed system provides more secure and authorized way of recover the text in cloud storage with access control. Finally, our experimental result shows that our system is better than existing.

  13. Stability of interbed for salt cavern gas storage in solution mining considering cusp displacement catastrophe theory

    Directory of Open Access Journals (Sweden)

    Le Yu

    2015-03-01

    Full Text Available Cusp displacement catastrophe theory can be introduced to propose a new method about instability failure of the interbed for gas storage cavern in bedded salt in solution mining. We can calculate initial fracture drawing pace of this interbed to obtain 2D and 3D gas storage shapes at this time. Moreover, Stability evaluation of strength reduction finite element method (FEM based on this catastrophe theory can used to evaluate this interbed stability after initial fracture. A specific example is simulated to obtain the influence of the interbed depth, cavern internal pressure, and cavern building time on stability safety factor (SSF. The results indicate: the value of SSF will be lower with the increase of cavern building time in solution mining and the increase of interbed depth and also this value remains a rise with the increase of cavern internal pressure Especially, we can conclude that the second-fracture of the interbed may take place when this pressure is lower than 6 MPa or after 6 days later of the interbed after initial fracture. According to above analysis, some effective measures, namely elevating the tube up to the top of the interbed, or changing the circulation of in-and-out lines, can be introduced to avoid the negative effects when the second-fracture of the interbed may occur.

  14. Influence of the nozzle angle on refrigeration performance of a gas wave refrigerator

    Science.gov (United States)

    Liu, P.; Zhu, Y.; Wang, H.; Zhu, C.; Zou, J.; Wu, J.; Hu, D.

    2017-05-01

    A gas wave refrigerator (GWR) is a novel refrigerating device that refrigerates a medium by shock waves and expansion waves generated by gas pressure energy. In a typical GWR, the injection energy losses between the nozzle and the expansion tube are essential factors which influence the refrigeration efficiency. In this study, numerical simulations are used to analyze the underlying mechanism of the injection energy losses. The results of simulations show that the vortex loss, mixing energy loss, and oblique shock wave reflection loss are the main factors contributing to the injection energy losses in the expansion tube. Furthermore, the jet angle of the gas is found to dominate the injection energy losses. Therefore, the optimum jet angle is theoretically calculated based on the velocity triangle method. The value of the optimum jet angle is found to be 4^{circ }, 8^{circ }, and 12^{circ } when the refrigeration efficiency is the first-order, second-order, and third-order maximum value over all working ranges of jet frequency, respectively. Finally, a series of experiments are conducted with the jet angle ranging from -4^{circ } to 12^{circ } at a constant expansion ratio. The results indicate the optimal jet angle obtained by the experiments is in good agreement with the calculated value. The isentropic refrigeration efficiency increased by about 4 % after the jet angle was optimized.

  15. Refrigeration generation using expander-generator units

    Science.gov (United States)

    Klimenko, A. V.; Agababov, V. S.; Koryagin, A. V.; Baidakova, Yu. O.

    2016-05-01

    The problems of using the expander-generator unit (EGU) to generate refrigeration, along with electricity were considered. It is shown that, on the level of the temperatures of refrigeration flows using the EGU, one can provide the refrigeration supply of the different consumers: ventilation and air conditioning plants and industrial refrigerators and freezers. The analysis of influence of process parameters on the cooling power of the EGU, which depends on the parameters of the gas expansion process in the expander and temperatures of cooled environment, was carried out. The schematic diagram of refrigeration generation plant based on EGU is presented. The features and advantages of EGU to generate refrigeration compared with thermotransformer of steam compressive and absorption types were shown, namely: there is no need to use the energy generated by burning fuel to operate the EGU; beneficial use of the heat delivered to gas from the flow being cooled in equipment operating on gas; energy production along with refrigeration generation, which makes it possible to create, using EGU, the trigeneration plants without using the energy power equipment. It is shown that the level of the temperatures of refrigeration flows, which can be obtained by using the EGU on existing technological decompression stations of the transported gas, allows providing the refrigeration supply of various consumers. The information that the refrigeration capacity of an expander-generator unit not only depends on the parameters of the process of expansion of gas flowing in the expander (flow rate, temperatures and pressures at the inlet and outlet) but it is also determined by the temperature needed for a consumer and the initial temperature of the flow of the refrigeration-carrier being cooled. The conclusion was made that the expander-generator units can be used to create trigeneration plants both at major power plants and at small energy.

  16. Monitoring Groundwater Storage Changes in the Loess Plateau Using GRACE Satellite Gravity Data, Hydrological Models and Coal Mining Data

    Directory of Open Access Journals (Sweden)

    Xiaowei Xie

    2018-04-01

    Full Text Available Monitoring the groundwater storage (GWS changes is crucial to the rational utilization of groundwater and to ecological restoration in the Loess Plateau of China, which is one of the regions with the most extreme ecological environmental damage in the world. In this region, the mass loss caused by coal mining can reach the level of billions of tons per year. For this reason, in this work, in addition to Gravity Recovery and Climate Experiment (GRACE satellite gravity data and hydrological models, coal mining data were also used to monitor GWS variation in the Loess Plateau during the period of 2005–2014. The GWS changes results from different GRACE solutions, that is, the spherical harmonics (SH solutions, mascon solutions, and Slepian solutions (which are the Slepian localization of SH solutions, were compared with in situ GWS changes, obtained from 136 groundwater observation wells, and the aim was to acquire the most robust GWS changes. The results showed that the GWS changes from mascon solutions (mascon-GWS match best with in situ GWS changes, showing the highest correlation coefficient, lowest root mean square error (RMSE values and nearest annual trend. Therefore, the Mascon-GWS changes are used for the spatial-temporal analysis of GWS changes. Based on which, the groundwater depletion rate of the Loess Plateau was −0.65 ± 0.07 cm/year from 2005–2014, with a more severe consumption rate occurring in its eastern region, reaching about −1.5 cm/year, which is several times greater than those of the other regions. Furthermore, the precipitation and coal mining data were used for analyzing the causes of the groundwater depletion: the results showed that seasonal changes in groundwater storage are closely related to rainfall, but the groundwater consumption is mainly due to human activities; coal mining in particular plays a major role in the serious groundwater consumption in eastern region of the study area. Our results will help in

  17. Efficiency improvement of commercial refrigeration systems

    Energy Technology Data Exchange (ETDEWEB)

    Denecke, Julius [NTNU, Trondheim (Norway); Hafner, Armin [SINTEF Energy Research, Trondheim (Norway)

    2011-07-01

    This work presents a historical review of carbon dioxide refrigeration systems. Further a literature survey is carried out to get a status of existing refrigeration technology related to supermarkets. In the next step various energy saving options are stated. A heat recovery model, basing on a R744 booster refrigeration system is established and described. Simplified demand curves for refrigeration, air conditioning and heating will base this model to calculate different heat recovery layouts. Supermarket future trends will be considered and integrated in the calculation. Finally the calculated energy consumptions will be compared with real energy consumptions of selected supermarket refrigeration systems.

  18. THERMODYNAMIC PROPERTIES OF SELECTED HFC REFRIGERANTS

    Science.gov (United States)

    Hydrofluorocarbon (HFC) refrigerants are possible alternatives to replace ozone-depleting chlorofluorocarbon and hydrochlorofluorocarbon (HCFC) refrigerants. The flammability of a proposed new refrigerant is a major consideration in assessing its utility for a particular applicat...

  19. Studies on the quality of duck meat sausages during refrigeration

    OpenAIRE

    Naveen, Z.; Naik, B. R.; Subramanyam, B. V.; Reddy, P. M.

    2016-01-01

    Duck farming is on the raise in the current scenario, but processed products from duck meat are still uncommon to find. Investigating the duck meat qualities during storage will provide information to enhance duck meat utilization. Development of ready-to-eat and ready-to-cook duck meat products is expected to increase and improve non-chicken meat-based protein. The Study was aimed to evaluate the changes in quality characteristics of duck meat sausages preserved by refrigeration (7???1??C). ...

  20. CFD Parametric Studies for Global Performance Improvement of Open Refrigerated Display Cabinets

    Directory of Open Access Journals (Sweden)

    Pedro Dinis Gaspar

    2012-01-01

    Full Text Available A detailed CFD modelling of an open refrigerated display cabinet has been formulated in a previous study. Some modifications are introduced in order to perform parametric studies dealing with low-cost geometrical and functional characteristics for improvement of the global performance and energy efficiency. The parametric studies are devoted to the analysis of the thermal response and behaviour inside the food conservation space influenced by (1 air flow rate through the evaporator heat exchanger; (2 air curtain behaviour; (3 hole dimensions and distribution of the back panel; (4 discharge and return grilles angles; and (5 flow deflectors inside the internal duct. The analysis of the numerical predictions from the parametric studies allows the development of an optimized model for the conception of an open refrigerated display cabinet with a more adequate configuration. The numerical predictions of the optimized model show lower product temperature and reduced electrical energy consumption, allowing the improvement of the food safety and the energy rationalization of the refrigeration equipment.

  1. Design of refrigeration system using refrigerant R134a for macro compartment

    Science.gov (United States)

    Rani, M. F. H.; Razlan, Z. M.; Shahriman, A. B.; Yong, C. K.; Harun, A.; Hashim, M. S. M.; Faizi, M. K.; Ibrahim, I.; Kamarrudin, N. S.; Saad, M. A. M.; Zunaidi, I.; Wan, W. K.; Desa, H.

    2017-10-01

    The main objective of this study is to analyse and design an optimum cooling system for macro compartment. Current product of the refrigerator is not specified for single function and not compact in size. Hence, a refrigeration system using refrigerant R134a is aimed to provide instant cooling in a macro compartment with sizing about 150 × 150 × 250 mm. The macro compartment is purposely designed to fit a bottle or drink can, which is then cooled to a desired drinking temperature of about 8°C within a period of 1 minute. The study is not only concerned with analysing of heat load of the macro compartment containing drink can, but also focused on determining suitable heat exchanger volume for both evaporator and condenser, calculating compressor displacement value and computing suitable resistance value of the expansion valve. Method of optimization is used to obtain the best solution of the problem. Mollier diagram is necessary in the process of developing the refrigeration system. Selection of blower is made properly to allow air circulation and to increase the flow rate for higher heat transfer rate. Property data are taken precisely from thermodynamic property tables. As the main four components, namely condenser, compressor, evaporator and expansion valve are fully developed, the refrigeration system is complete.

  2. Overall performance of the duplex Stirling refrigerator

    International Nuclear Information System (INIS)

    Erbay, L. Berrin; Ozturk, M. Mete; Doğan, Bahadır

    2017-01-01

    Highlights: • Overall performance coefficient of duplex Stirling refrigerator was investigated. • A definite region for the coefficient of performance of the refrigerator in duplex Stirling is identified. • A definite region for the thermal efficiency of the heat engine in duplex Stirling is identified. • Benchmark values and design bounds of the duplex Stirling refrigerator were obtained. - Abstract: The duplex Stirling refrigerator is an integrated refrigerator consists of Stirling cycle engine and Stirling cycle refrigerator used for cooling. The equality of the work generation of the heat engine to the work consumption of the refrigerator is the primary constraint of the duplex Stirling. The duplex Stirling refrigerator is investigated thermodynamically by considering the effects of constructional and operational parameters which are namely the temperature ratios for heat engine and refrigerator, and the compression ratios for both sides. The primary concern is given to the parametric effects on the overall coefficient of performance of the duplex Stirling refrigerator. The given diagrams provide a design bounds and benchmark results that allows seeing the big picture about the cooling load and heat input relation. Moreover they ease to determine the corresponding work rate to the target cooling load. As regard to the obtained results, a definite region for coefficient of performance of the refrigerator and a definite region for the thermal efficiency of the heat engine of the duplex Stirling are identified.

  3. Post-mining safety implementations and environmental aspects of abandoned mine sites in Limousin. 2006 status (and perspectives 2007)

    International Nuclear Information System (INIS)

    2007-01-01

    This document summarizes the actions carried out in 2006 at some French abandoned mine sites: 1 - safety implementations and risks abatement in the framework of post-mining actions: coal mines of Ahun (23) and Argentat (19), antimony mines of Biard (87); 2 - remedial actions at the tin/tungsten mine of Puy-les-Vignes (87) and at the gold mine of Chatelet (23); 3 - 2007 post-mining perspectives; 4 - environmental aspects of abandoned mine sites: gold mines of Chatelet (23), Cheni and Bourneix (87), uranium mines of Haute-Vienne (expertise, control of effluents, financial warranties about tailings storage sites maintenance). (J.S.)

  4. Microbiological and physicochemical profile of traditional Salsiccia toscana during storage

    Directory of Open Access Journals (Sweden)

    Giovanna Preziuso

    2012-07-01

    Full Text Available The aim of this study was to evaluate the evolution during refrigerated storage of the main microbiological and physicochemical parameters of a traditional Italian fresh sausage, salsiccia toscana. The following parameters were analyzed at Days 0, 6 and 9 of storage: total aerobic mesophilic and psychrotrophic counts, Brochothrix thermosphacta, lactic acid bacteria, Pseudomonadaceae, Enterobacteriaceae, Escherichia coli, Micrococcaceae, yeasts and moulds, Salmonella spp., Listeria monocytogenes; pH, Aw, moisture, protein, total lipids, ash, fatty acid composition, Thiobarbituric Acid Reactive Substances, colour measurement. The results revealed a statistically significant increase in the main microbiological parameters between Days 0 and 9 of refrigerated storage, with total bacterial counts exceeding 107 CFU/g after nine days and Brochothrix thermosphacta representing the main spoilage microorganism. Among physicochemical parameters, discolouration was noted during the time of storage, with a significantly paler colour on the surface of sausages with casings after nine days of storage. Considering that the initial bacterial counts were higher than 105 CFU/g for Brochothrix thermosphacta, Pseudomonadaceae, lactic acid bacteria and Enterobacteriaceae, and that the product is traditionally purchased loose without any packaging, it is fundamental to improve the good manufacturing practices, particularly measures to control processing temperatures.

  5. Model of refrigerated display-space allocation for multi agro-perishable products considering markdown policy

    Science.gov (United States)

    Satiti, D.; Rusdiansyah, A.

    2018-04-01

    Problems that need more attention in the agri-food supply chain are loss and waste as consequences from improper quality control and excessive inventories. The use of cold storage is still being one of favourite technologies in controlling product quality by majority of retailers. We considerate the temperature of cold storage in determining the inventory and pricing strategies based on identified product quality. This study aims to minimize the agri-food waste, utility of cold storage facilities and maximize retailer’s profit through determining the refrigerated display-space allocation and markdown policy based on identified food shelf life. The proposed model evaluated with several different scenarios to find out the right strategy.

  6. An experimental investigation on a novel ejector enhanced refrigeration cycle applied in the domestic refrigerator-freezer

    International Nuclear Information System (INIS)

    Wang, Xiao; Yu, Jianlin

    2015-01-01

    This paper presents an experimental investigation on a NERC (novel ejector enhanced refrigeration cycle) applied in the domestic refrigerator-freezer (BCD-249). Experimental studies were conducted to validate the NERC system feasibility in a practical NERC based refrigerator-freezer prototype. The system performances of energy consumption, ejector pressure lift ratio and compressor power were compared under different combinations of system configuration parameters. The results showed that the NERC system could effectively reduce the thermodynamic losses in the throttle processing. The minimum energy consumption of 0.520 kWh 24 h"−"1 was obtained for the NERC prototype, indicating 5.45% energy consumption reduction compared with the conventional domestic refrigerator-freezer. Furthermore, the effects of system configuration parameters including the refrigerant charge amount, the compressor displacement and the length of capillary tube were investigated. This study aims at providing deep insight into ejector-expansion technology applied in domestic refrigerator-freezers. - Highlights: • A NERC (novel ejector enhanced refrigeration cycle) was experimentally studied. • 73 experimental data points with different system configuration were acquired. • Energy consumption could be reduced with optimum system configuration. • 5.45% energy consumption reduction is obtained compared with the conventional system.

  7. Transport-location model of mine supply with timber. [Poland

    Energy Technology Data Exchange (ETDEWEB)

    Krause, E; Piasecki, B; Srutwa, J

    1981-01-01

    Underground black coal mines in Poland consume about 2 million m/sup 3/ of wood per year. Wood supply to coal mines will remain constant in spite of the planned coal output increase and assumed deterioration of mining conditions. An economic analysis of cost of rock strata control in coal mines is presented. The analysis concentrates on the proportion of wood cost in the total cost of strata control. Methods for reducing cost of wood supply to coal mines are analyzed using mathematical models. Transport system of wood to coal mines and within coal mines is analyzed. Site selection for storage facilities for wood, particularly wooden props, is evaluated. A mathematical model used for optimizing site selection is described. Economic effects associated with optimizing site selection of storage facilities for wood on mining cost and strata conrol cost in underground mining are described. (4 refs.)

  8. Improving the energy efficiency of industrial refrigeration systems

    International Nuclear Information System (INIS)

    Oh, Jin-Sik; Binns, Michael; Park, Sangmin; Kim, Jin-Kuk

    2016-01-01

    Various retrofit design options are available for improving the energy efficiency and economics of industrial refrigeration systems. This study considers a novel retrofit option using a mixed refrigerant (MR) in refrigeration cycles designed for use with a pure refrigerant (PR). In this way energy savings can be realized by switching refrigerants without requiring extensive and expensive reconfiguration of equipment. Hence, the aim here is to test the common thinking that equipment should always be extensively reconfigured when switching from pure to mixed refrigerants. To determine the most energy-efficient operating conditions for each refrigeration design an optimization framework is utilized linking a process simulator with an external optimization method. A case study is presented to demonstrate how the proposed process modeling and optimization framework can be applied and to illustrate the economic benefits of using the retrofit design options considered here. For the case considered in this paper, savings of shaft power required for the refrigeration cycle can be achieved from 16.3% to 27.2% when the pure refrigerant is replaced with mixed refrigerants and operating conditions are re-optimized. - Highlights: • Design methods for the design of refrigeration cycles in retrofit cases. • Consideration of mixed refrigerants to the existing multi-level pure-refrigerant cycles. • Optimization of refrigeration cycles with integrated use of a process simulator with an optimizer.

  9. Mine planning and scheduling at Ranger Uranium Mine - environmental requirements and economics

    International Nuclear Information System (INIS)

    Bath, L.J.

    1984-01-01

    Ranger Uranium Mines operates an open cut located in the Northern Territory. Strict environmental controls govern all operations and the water management requirements have the greatest impact on mine planning. The two main goals of planning are to provide mill feed and to mine sufficient suitable quality waste rock for ongoing construction of the tailings dam. Early planning concentrated on staged development of the pit to provide access to as much ore as possible for a given amount of development. All waste was considered to be suitable construction material. Grade control of crusher feed was the main problem in planning, as wide variations occur in ore grade over relatively short distances. Water management for the site operates a 'no release' system for contaminated waters. Design storage has proven inadequate, and the open cut has been used as the extra storage. As construction of future stages of the tailings dam requires non-mineralised rock materials which meet specific quality criteria, the mine has had to re-examine long term planning and pit development strategies. This has entailed the collection of much data not required under normal mining conditions, such as the assaying of waste drill core. The overall impact on mine planning of the environmental regulations has been to alter the philosophy of earlier planning, making it necessary to create a new strategy for pit development with the accent on exposing waste

  10. Experimental evaluation of desuperheating and oil cooling process through liquid injection in two-staged ammonia refrigeration systems with screw compressors

    International Nuclear Information System (INIS)

    Zlatanović, Ivan; Rudonja, Nedžad

    2012-01-01

    This paper examines the problem of achieving desuperheating through liquid injection in two-staged refrigeration systems based on screw compressors. The oil cooling process by refrigerant injection is also included. The basic thermodynamic principles of desuperheating and compressor cooling as well as short comparison with traditional method with a thermosyphon system have also been presented. Finally, the collected data referring to a big refrigeration plant are analyzed in the paper. Specific ammonia system concept applied in this refrigeration plant has demonstrated its advantages and disadvantages. - Highlights: ► An experiment was setup during a frozen food factory refrigeration system reconstruction and adaptation. ► Desuperheating and low-stage compressors oil cooling process were investigated. ► Efficiency of compression process and high-stage compressors functioning were examined. ► Evaporation temperature reduction has great influence on the need for injected liquid refrigerant. ► Several cases in which desuperheating and oil cooling process application are justified were determined.

  11. Research on parallel algorithm for sequential pattern mining

    Science.gov (United States)

    Zhou, Lijuan; Qin, Bai; Wang, Yu; Hao, Zhongxiao

    2008-03-01

    Sequential pattern mining is the mining of frequent sequences related to time or other orders from the sequence database. Its initial motivation is to discover the laws of customer purchasing in a time section by finding the frequent sequences. In recent years, sequential pattern mining has become an important direction of data mining, and its application field has not been confined to the business database and has extended to new data sources such as Web and advanced science fields such as DNA analysis. The data of sequential pattern mining has characteristics as follows: mass data amount and distributed storage. Most existing sequential pattern mining algorithms haven't considered the above-mentioned characteristics synthetically. According to the traits mentioned above and combining the parallel theory, this paper puts forward a new distributed parallel algorithm SPP(Sequential Pattern Parallel). The algorithm abides by the principal of pattern reduction and utilizes the divide-and-conquer strategy for parallelization. The first parallel task is to construct frequent item sets applying frequent concept and search space partition theory and the second task is to structure frequent sequences using the depth-first search method at each processor. The algorithm only needs to access the database twice and doesn't generate the candidated sequences, which abates the access time and improves the mining efficiency. Based on the random data generation procedure and different information structure designed, this paper simulated the SPP algorithm in a concrete parallel environment and implemented the AprioriAll algorithm. The experiments demonstrate that compared with AprioriAll, the SPP algorithm had excellent speedup factor and efficiency.

  12. A concept for the modernization of underground mining master maps based on the enrichment of data definitions and spatial database technology

    Science.gov (United States)

    Krawczyk, Artur

    2018-01-01

    In this article, topics regarding the technical and legal aspects of creating digital underground mining maps are described. Currently used technologies and solutions for creating, storing and making digital maps accessible are described in the context of the Polish mining industry. Also, some problems with the use of these technologies are identified and described. One of the identified problems is the need to expand the range of mining map data provided by survey departments to other mining departments, such as ventilation maintenance or geological maintenance. Three solutions are proposed and analyzed, and one is chosen for further analysis. The analysis concerns data storage and making survey data accessible not only from paper documentation, but also directly from computer systems. Based on enrichment data, new processing procedures are proposed for a new way of presenting information that allows the preparation of new cartographic representations (symbols) of data with regard to users' needs.

  13. HeREF-2003: Helium Refrigeration Techniques

    CERN Multimedia

    2003-01-01

    CERN Technical Training 2003: Learning for the LHC ! Theory, Technology, Maintenance and Control of Helium Refrigerators HeREF-2003 is a course in the framework of the 2002 Technical Training Programme, that will provide a complete introduction to Helium refrigeration, with a practical approach to theory, technology, maintenance and control of Helium refrigeration installations. Theoretical aspects and equations will be limited to a minimum. HeREF-2003 targets an audience of technicians and operators of Helium refrigeration plants at CERN, as well as physicists and engineers needing an overview of current Helium refrigeration techniques. HeREF-2003 will address, among other, issues related to component technology, installation maintenance, process control and Helium purity. A commented visit to a couple of CERN Helium refrigeration or liquefaction plants will also take place. Duration: 7 half days (4 mornings and 3 afternoons), 6-10 October, 2003 Cost per participant: 500.- CHF Language: Bilingual English...

  14. HeREF-2003 : Helium Refrigeration Techniques

    CERN Multimedia

    2003-01-01

    CERN Technical Training 2003: Learning for the LHC ! Theory, Technology, Maintenance and Control of Helium Refrigerators HeREF-2003 is a course in the framework of the 2002 Technical Training Programme, that will provide a complete introduction to Helium refrigeration, with a practical approach to theory, technology, maintenance and control of Helium refrigeration installations. Theoretical aspects and equations will be limited to a minimum. HeREF-2003 targets an audience of technicians and operators of Helium refrigeration plants at CERN, as well as physicists and engineers needing an overview of current Helium refrigeration techniques. HeREF-2003 will address, among other, issues related to component technology, installation maintenance, process control and Helium purity. A commented visit to a couple of CERN Helium refrigeration or liquefaction plants will also take place. • Duration: 7 half days (4 mornings and 3 afternoons), 6-10 October, 2003 • Cost per participant: 500.- CHF ...

  15. Magnetocaloric refrigeration near room temperature (invited)

    International Nuclear Information System (INIS)

    Brueck, E.; Tegus, O.; Thanh, D.T.C.; Buschow, K.H.J.

    2007-01-01

    Modern society relies on readily available refrigeration. The ideal cooling machine would be a compact, solid state, silent and energy-efficient heat pump that does not require maintenance. Magnetic refrigeration has three prominent advantages compared to compressor-based refrigeration. First, there are no harmful gases involved, second it may be built more compact as the working material is a solid and third magnetic refrigerators generate much less noise. Recently, a new class of magnetic refrigerant materials for room-temperature applications was discovered. These new materials have important advantages over existing magnetic coolants: They exhibit a large magnetocaloric effect (MCE) in conjunction with a magnetic phase transition of first order. This MCE is, larger than that of Gd metal, which is used in the demonstration refrigerators built to explore the potential of this evolving technology. In the present review, we compare the different materials considering both scientific aspects and industrial applicability

  16. Analysis of Refrigeration Cycle Performance with an Ejector

    Directory of Open Access Journals (Sweden)

    Wani J. R.

    2016-01-01

    Full Text Available A conventional refrigeration cycle uses expansion device between the condenser and the evaporator which has losses during the expansion process. A refrigeration cycle with ejector is a promising modification to improve the performance of conventional refrigeration cycle. The ejector is used to recover some of the available work so that the compressor suction pressure increases. To investigate the enhancement a model with R134a refrigerant was developed. To solve the set of equations and simulate the cycle performance a subroutine was written on engineering equation solver (EES environment. At specific conditions, the refrigerant properties are obtained from EES. At the design conditions the ejector refrigeration cycle achieved 5.141 COP compared to 4.609 COP of the conventional refrigeration cycle. This means that ejector refrigeration cycle offers better COP with 10.35% improvement compared to conventional refrigeration cycle. Parametric analysis of ejector refrigeration cycle indicated that COP was influenced significantly by evaporator and condenser temperatures, entrainment ratio and diffuser efficiency.

  17. The open cast mine of Bertholene (France)

    International Nuclear Information System (INIS)

    Fraisse, H.

    1986-01-01

    The uranium deposit is described. Geology, exploration, reserve estimates, mining, mining equipment, utilities storage, environment and safety are presented. In appendixes data are given on drilling, loading and transport [fr

  18. Ultimate storage of spent fuel elements from the AVR experimental nuclear power plant in the Asse Salt Mine

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, J.

    1975-02-15

    The present paper is intended to serve as the basis for the licensing procedures both in respect of the transport and storage techniques and also for the ultimate storage itself. In regard to the technique it will be shown on the basis of design drawings and calculations that the handling, transport and storage of the fuel elements can be safely carried out in accordance with the regulations in force. In regard to the ultimate storage itself, since no highly radioactive wastes with a long-lived actinide content have yet been stored, it will be necessary to show that an unacceptable contamination of the biosphere will be avoided even in the long term under all anticipated conditions. It will further be necessary to show by calculations and suitable tests, in view of the radioactive gas and fissile material content, that no danger due to gas release from the fuel elements will arise during the operating life of the mine and that a nuclear criticality risk can be excluded for all time.

  19. Synthesis document on the storage and packages concepts: phenomenological and operational reference corrosion HAVL

    International Nuclear Information System (INIS)

    Helie, M.; Bataillon, Ch.; Desgranges, C.; Perrin, S.

    2004-12-01

    In the today concept, the long life high activity nuclear wastes (HAVL) would be storage in metallic containers. In the framework of the COCON program, simulations and knowledge of the corrosion problems bond to the wastes containers management are realized, in order to predict the long time behavior of packages storage and disposal. This reference document takes stock on the knowledge and the scientific simulation of corrosion phenomena which are decisive for the long life behavior of the external metallic wall of high activity nuclear wastes packages for the storage and the disposal and aims to provide bases of an operational modelization of these phenomena. (A.L.B.)

  20. Effects of storage conditions of Moringa oleifera seeds on its performance in coagulation.

    Science.gov (United States)

    Katayon, S; Noor, M J Megat Mohd; Asma, M; Ghani, L A Abdul; Thamer, A M; Azni, I; Ahmad, J; Khor, B C; Suleyman, A M

    2006-09-01

    Moringa oleifera is a plant whose seeds have coagulation properties for treating water and wastewater. In this study the coagulation efficiency of Moringa oleifera kept in different storage conditions were studied. The Moringa oleifera seeds were stored at different conditions and durations; open container and closed container at room temperature (28 degrees C) and refrigerator (3 degrees C) for durations of 1, 3 and 5 months. Comparison between turbidity removal efficiency of Moringa oleifera kept in refrigerator and room temperature revealed that there was no significant difference between them. The Moringa oleifera kept in refrigerator and room temperature for one month showed higher turbidity removal efficiency, compared to those kept for 3 and 5 months, at both containers. The coagulation efficiency of Moringa oleifera was found to be dependent on initial turbidity of water samples. Highest turbidity removals were obtained for water with very high initial turbidity. In summary coagulation efficiency of Moringa oleifera was found independent of storage temperature and container, however coagulation efficiency of Moringa oleifera decreased as storage duration increased. In addition, Moringa oleifera can be used as a potential coagulant especially for very high turbidity water.

  1. Development of Low Global Warming Potential Refrigerant Solutions for Commercial Refrigeration Systems using a Life Cycle Climate Performance Design Tool

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, Omar [ORNL; Fricke, Brian A [ORNL; Vineyard, Edward Allan [ORNL

    2012-01-01

    Commercial refrigeration systems are known to be prone to high leak rates and to consume large amounts of electricity. As such, direct emissions related to refrigerant leakage and indirect emissions resulting from primary energy consumption contribute greatly to their Life Cycle Climate Performance (LCCP). In this paper, an LCCP design tool is used to evaluate the performance of a typical commercial refrigeration system with alternative refrigerants and minor system modifications to provide lower Global Warming Potential (GWP) refrigerant solutions with improved LCCP compared to baseline systems. The LCCP design tool accounts for system performance, ambient temperature, and system load; system performance is evaluated using a validated vapor compression system simulation tool while ambient temperature and system load are devised from a widely used building energy modeling tool (EnergyPlus). The LCCP design tool also accounts for the change in hourly electricity emission rate to yield an accurate prediction of indirect emissions. The analysis shows that conventional commercial refrigeration system life cycle emissions are largely due to direct emissions associated with refrigerant leaks and that system efficiency plays a smaller role in the LCCP. However, as a transition occurs to low GWP refrigerants, the indirect emissions become more relevant. Low GWP refrigerants may not be suitable for drop-in replacements in conventional commercial refrigeration systems; however some mixtures may be introduced as transitional drop-in replacements. These transitional refrigerants have a significantly lower GWP than baseline refrigerants and as such, improved LCCP. The paper concludes with a brief discussion on the tradeoffs between refrigerant GWP, efficiency and capacity.

  2. Offshore wind energy storage concept for cost-of-rated-power savings

    International Nuclear Information System (INIS)

    Qin, Chao; Saunders, Gordon; Loth, Eric

    2017-01-01

    Highlights: •Investigated CAES + HPT system concept for offshore wind energy; •Validated cost model for offshore wind farm including CAPEX and OPEX items; •Quantified cost-of-rated-power savings associated with CAES + HPT concept; •Estimated savings of 21.6% with CAES + HPT for a sample $2.92 billion project. -- Abstract: The size and number of off-shore wind turbines over the next decade is expected to rapidly increase due to the high wind energy potential and the ability of such farms to provide utility-scale energy. In this future, inexpensive and efficient on-site wind energy storage can be critical to address short-time (hourly) mismatches between wind supply and energy demand. This study investigates a compressed air energy storage (CAES) and hydraulic power transmission (HPT) system concept. To assess cost impact, the NREL Cost and Scaling Model was modified to improve accuracy and robustness for offshore wind farms with large turbines. Special attention was paid to the support structure, installation, electrical interface and connections, land leasing, and operations and maintenance cost items as well as specific increased/reduced costs reductions associated with CAES + HPT systems. This cost model was validated and applied to a sample $2.92 billion project Virginia Offshore case It was found that adaption of CAES + HPT can lead to a substantial savings of 21.6% of this 20-year lifetime cost by dramatically reducing capital and operating cost of the generator and power transmission components. However, there are several additional variables that can impact the off-shore energy policy and planning for this new CAES + HPT concept. Furthermore, these cost-savings are only first-order estimates based on linear mass-cost relationships, and thus detailed engineering and economic analysis are recommended.

  3. 49 CFR 173.174 - Refrigerating machines.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Refrigerating machines. 173.174 Section 173.174 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... Refrigerating machines. A refrigerating machine assembled for shipment and containing 7 kg (15 pounds) or less...

  4. Data mining in Cloud Computing

    Directory of Open Access Journals (Sweden)

    Ruxandra-Ştefania PETRE

    2012-10-01

    Full Text Available This paper describes how data mining is used in cloud computing. Data Mining is used for extracting potentially useful information from raw data. The integration of data mining techniques into normal day-to-day activities has become common place. Every day people are confronted with targeted advertising, and data mining techniques help businesses to become more efficient by reducing costs.Data mining techniques and applications are very much needed in the cloud computing paradigm. The implementation of data mining techniques through Cloud computing will allow the users to retrieve meaningful information from virtually integrated data warehouse that reduces the costs of infrastructure and storage.

  5. Thermodynamic analysis of hydrocarbon refrigerants in a sub-cooling refrigeration system

    Directory of Open Access Journals (Sweden)

    BUKOLA O. BOLAJI

    2013-06-01

    Full Text Available In this study, the performance simulation of some hydrocarbon refrigerants (R290, R600 and R600a as alternatives to R134a in refrigeration system with sub-cooling is conducted by thermodynamic calculation of performance parameters using the REFPROP software. The results obtained showed that the saturated vapour pressure and temperature characteristic profiles for R600 and R600a are very close to that of R134a. The three hydrocarbon refrigerants exhibited very high refrigerating effect and condenser duty than R134a. The best of these parameters was obtained using R600. The discharge temperatures obtained using R600 and R600a were low, while that of R290 was very much higher. The highest coefficient of performance (COP and relative capacity index were obtained using R600. Average COPs of R600 and R600a are 4.6 and 2.2% higher than that of R134a, respectively. The performances of R600 and R600a in system were better than those of R134a and R290. The best performance was obtained using R600 in the system.

  6. ARTI Refrigerant Database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1992-11-09

    The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air- conditioning and refrigeration equipment. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R- 717 (ammonia), ethers, and others as well as azeotropic and zeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents on compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. A computerized version is available that includes retrieval software.

  7. An Educational Data Mining Approach to Concept Map Construction for Web based Learning

    Directory of Open Access Journals (Sweden)

    Anal ACHARYA

    2017-01-01

    Full Text Available This aim of this article is to study the use of Educational Data Mining (EDM techniques in constructing concept maps for organizing knowledge in web based learning systems whereby studying their synergistic effects in enhancing learning. This article first provides a tutorial based introduction to EDM. The applicability of web based learning systems in enhancing the efficiency of EDM techniques in real time environment is investigated. Web based learning systems often use a tool for organizing knowledge. This article explores the use of one such tool called concept map for this purpose. The pioneering works by various researchers who proposed web based learning systems in personalized and collaborative environment in this arena are next presented. A set of parameters are proposed based on which personalized and collaborative learning applications may be generalized and their performances compared. It is found that personalized learning environment uses EDM techniques more exhaustively compared to collaborative learning for concept map construction in web based environment. This article can be used as a starting point for freshers who would like to use EDM techniques for concept map construction for web based learning purposes.

  8. A new design concept for nodule mining system

    Digital Repository Service at National Institute of Oceanography (India)

    Janakiraman, G.; Venkatesan, R.; Rajaraman, V.S.

    An overview is presented on the hazards associated with various types of equipment to be used for the commercial mining of nodules from the seabed. The design of a suitable mining collector and the various options available are discussed. A novel...

  9. Working with Data: Discovering Knowledge through Mining and Analysis; Systematic Knowledge Management and Knowledge Discovery; Text Mining; Methodological Approach in Discovering User Search Patterns through Web Log Analysis; Knowledge Discovery in Databases Using Formal Concept Analysis; Knowledge Discovery with a Little Perspective.

    Science.gov (United States)

    Qin, Jian; Jurisica, Igor; Liddy, Elizabeth D.; Jansen, Bernard J; Spink, Amanda; Priss, Uta; Norton, Melanie J.

    2000-01-01

    These six articles discuss knowledge discovery in databases (KDD). Topics include data mining; knowledge management systems; applications of knowledge discovery; text and Web mining; text mining and information retrieval; user search patterns through Web log analysis; concept analysis; data collection; and data structure inconsistency. (LRW)

  10. Thermodynamic analysis of an absorption refrigeration system with ionic-liquid/refrigerant mixture as a working fluid

    International Nuclear Information System (INIS)

    Kim, Yoon Jo; Kim, Sarah; Joshi, Yogendra K.; Fedorov, Andrei G.; Kohl, Paul A.

    2012-01-01

    Thermodynamics of an ionic-liquid (IL) based absorption refrigeration system has been numerically analyzed. It provides an alternative to the normally toxic working fluids, such as the ammonia in conventional absorption systems. The use of ILs also eliminates crystallization and metal-compatibility problems of the water/LiBr system. Mixtures of refrigerants and imidazolium-based ILs are theoretically explored as the working fluid pairs in a miniature absorption refrigeration system, so as to utilize waste-heat to power a refrigeration/heat pump system for electronics cooling. A non-random two-liquid (NRTL) model was built and used to predict the solubility of the mixtures. Saturation temperatures at the evaporator and condenser were set at 25 °C and 50 °C, respectively, with the power dissipation of 100 W. Water in combination with [emim][BF 4 ] (1-ethyl-3-methylimidazolium tetrafluoroborate) gave the highest coefficient of performance (COP) around 0.9. The refrigerant/IL compatibility indicated by the circulation ratio, alkyl chain length of the IL, and thermodynamic properties of the refrigerants, such as latent heat of evaporation were proven to be important factors in determining the performance of the absorption system. The negative effect of high viscosity was mitigated by dilution of the IL with the refrigerant and the use of slightly larger microfluidic channel heat exchangers. -- Highlights: ► Mixtures of refrigerant/ionic-liquid are studied for absorption system. ► We carry out comprehensive theoretical thermodynamic analysis. ► The essential factors of refrigerant/IL affecting the performance are identified. ► Water/[emim][BF 4 ] showed the best performance of COP. ► The effects of high viscosity ILs on the system performance are not significant.

  11. Thermoacoustic refrigerator for space applications

    Science.gov (United States)

    Garrett, Steven L.; Adeff, Jay A.; Hofler, Thomas J.

    1993-10-01

    A new spacecraft cryocooler which uses resonant high-amplitude sound waves in inert gases to pump heat is described. The phasing of the thermoacoustic cycle is provided by thermal conduction. This 'natural' phasing allows the entire refrigerator to operate with only one moving part (the loudspeaker diaphragm). A space-qualified thermoacoustic refrigerator was flown on the Space Shuttle Discovery (STS-42) in January, 1992. It was entirely autonomous, had no sliding seals, required no lubrication, used mostly low-tolerance machined parts, and contained no expensive components. Thermoacoustics is shown to be a competitive candidate for food refrigerator/freezers and commercial/residential air conditioners. The design and performance of the Space Thermo/Acoustic Refrigerator (STAR) is described.

  12. Mathematical modelling of thermal storage systems for the food industry

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, A.; Lacarra, G. [Universidad Publica de Navarra Campus Arrosadia, Pamplona (Spain). Area de Tecnologia de Alimentos

    1999-07-01

    Dynamic mathematical models of two thermal storage systems used in the food industry to produce chilled water are presented; an ice-bank system and a holding tank system. The variability of the refrigeration demand with time was taken into account in the model. A zoned approach using mass and energy balances was applied. Heat transfer phenomena in the evaporator were modelled using empirical correlations. The experimental validation of the mathematical models on an ice-bank system at pilot plant scale, and a centralized refrigeration system with a holding tank in a winery, showed accurate prediction. Simple models are adequate to predict the dynamic behaviour of these refrigeration systems under variable heat loads. (Author)

  13. A miniature adsorption3HE refrigerator

    International Nuclear Information System (INIS)

    Duband, L.; Ravex, A.; Lange, A.

    1991-01-01

    A self-contained, recyclable laboratory 3 He refrigerator has been developed. The refrigerator is very compact, portable and is designed to be safe and reliable. The unit can easily be installed on the cold plate of a superfluid 4 He cryostat. Once bolted on the cold plate, operation of the refrigerator is controlled by a single heater. In this new design the refrigerator has a cylindrical geometry. The adsorption pump is placed above the condensation point to prevent convection during the condensation phase and to improve the pumping speed. The inhibition of convection reduces the load on the 4 He bath and increases the condensation efficiency. This refrigeration technique has great potential for space applications. The absence of moving parts makes the system reliable and vibration free. Its simplicity and the absence of external components facilitate its integration on a cryostat. In fact, a rocket-borne 3 He refrigerator has already been successfully flown and has demonstrated the feasibility of this method

  14. Not all counterclockwise thermodynamic cycles are refrigerators

    Science.gov (United States)

    Dickerson, R. H.; Mottmann, J.

    2016-06-01

    Clockwise cycles on PV diagrams always represent heat engines. It is therefore tempting to assume that counterclockwise cycles always represent refrigerators. This common assumption is incorrect: most counterclockwise cycles cannot be refrigerators. This surprising result is explored here for quasi-static ideal gas cycles, and the necessary conditions for refrigeration cycles are clarified. Three logically self-consistent criteria can be used to determine if a counterclockwise cycle is a refrigerator. The most fundamental test compares the counterclockwise cycle with a correctly determined corresponding Carnot cycle. Other criteria we employ include a widely accepted description of the functional behavior of refrigerators, and a corollary to the second law that limits a refrigerator's coefficient of performance.

  15. Cryogenic mixed refrigerant processes

    CERN Document Server

    Venkatarathnam, Gadhiraju

    2010-01-01

    Teaches the need for refrigerant mixtures, the type of mixtures that can be used for different refrigeration and liquefaction applications, the different processes that can be used and the methods to be adopted for choosing the components of a mixture and their concentration for different applications.

  16. Development of latent heat storage systems. New storage materials and concepts for solar energy, efficient use, and spaceflight applications. Entwicklung von Latentwaermespeichern. Neue Speichermaterialien und Konzepte fuer Solarenergie, rationelle Energienutzung und Raumfahrtanwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Glueck, A.; Krause, S.; Lindner, F.; Staehle, H.J.; Tamme, R. (DLR, Stuttgart (Germany). Inst. fuer Technische Thermodynamik)

    1991-11-01

    To extend the operational range of thermal energy storage systems and to provide access to new fields of applications, it is necessary to develop storage systems with higher energy densities than can be achieved with conventional materials. Advanced storage concepts such as latent heat storage and chemical storage are suitable for this. (orig.).

  17. Thermoacoustic engines and refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Swift, G.

    1996-12-31

    This report is a transcript of a practice lecture given in preparation for a review lecture on the operation of thermoacoustic engines and refrigerators. The author begins by a brief review of the thermodynamic principles underlying the operation of thermoacoustic engines and refrigerators. Remember from thermodynamics class that there are two kinds of heat engines, the heat engine or the prime mover which produces work from heat, and the refrigerator or heat pump that uses work to pump heat. The device operates between two thermal reservoirs at temperatures T{sub hot} and T{sub cold}. In the heat engine, heat flows into the device from the reservoir at T{sub hot}, produces work, and delivers waste heat into the reservoir at T{sub cold}. In the refrigerator, work flows into the device, lifting heat Q{sub cold} from reservoir at T{sub cold} and rejecting waste heat into the reservoir at T{sub hot}.

  18. United States: refrigeration industry blows hot

    International Nuclear Information System (INIS)

    Crawford, J.

    1997-01-01

    In the framework of the Kyoto convention on global warming, the american refrigeration industries have undertaken several organizations and contacts with governments and agencies in order to explain the real issues concerning the effects of refrigerant utilization in refrigerating machines on the greenhouse effect, taking into consideration the commercial impact that a ban on certain refrigerants could have on the industry's business. They argue that HFC utilization in this industry is fundamentally non-emissive and that important improvements have been realized concerning tightness and energy consumption

  19. South African mine valuation

    Energy Technology Data Exchange (ETDEWEB)

    Storrar, C D

    1977-01-01

    This article sets out the basic concepts of mine valuation, with gold mining receiving more space than base minerals and coal. Sampling practice is given special attention. Chapter headings are methods of investigation, sampling, underground sampling, averaging of underground sampling, diamond-drill sampling, mass and mineral content of ore, organization of a sample office, working costs, mining pay limits, ore reserves, ore accounting, maintenance of grade, forecasting operations and life of mine, statistical mine valuation, state's share of profits and taxation, and financial valuation of mining ventures.

  20. Sorption compressor/mechanical expander hybrid refrigeration

    Science.gov (United States)

    Jones, J. A.; Britcliffe, M.

    1987-01-01

    Experience with Deep Space Network (DSN) ground-based cryogenic refrigerators has proved the reliability of the basic two-stage Gifford-McMahon helium refrigerator. A very long life cryogenic refrigeration system appears possible by combining this expansion system or a turbo expansion system with a hydride sorption compressor in place of the usual motor driven piston compressor. To test the feasibility of this system, a commercial Gifford-McMahon refrigerator was tested using hydrogen gas as the working fluid. Although no attempt was made to optimize the system for hydrogen operation, the refrigerator developed 1.3 W at 30 K and 6.6 W at 60 K. The results of the test and of theoretical performances of the hybrid compressor coupled to these expansion systems are presented.

  1. Constor steel concrete sandwich cask concept for transport and storage of spent nuclear fuel

    International Nuclear Information System (INIS)

    Diersch, R.; Dreier, G.; Gluschke, K.; Zubkov, A.; Danilin, B.; Fromzel, V.

    1998-01-01

    A spent nuclear fuel transport and storage sandwich cask concept has been developed together with the Russian company CKTI. Special consideration was given to an economical and effective way of manufacturing by using conventional mechanical engineering technologies and common materials. The main objective of this development was to fabricate these casks in countries not having highly specialized industries. Nevertheless, this sandwich cask concept fulfills both the internationally valid IAEA criteria for transportation and the German criteria for long-term intermediate storage. The basic cask concept has been designed for adaptation to different spent fuel specifications as well as handling conditions in the NPP. Recently, adaptations have been made for spent fuel from the RBMK and VVER reactors, and also for BWR spent fuel. The analyses of nuclear and thermal behaviour as well as of strength according to IAEA examination requirements (9-m-drop, 1-m-pin drop, 800 deg. C-fire test) and of the behaviour during accident scenarios at the storage site (drop, fire, gas cloud explosion, side impact) were carried out by means of recognized calculation methods and programmes. In a special experimental programme, the mechanical and thermodynamic properties of heavy concrete were examined and the reference values required for safety analyses were determined. The results of the safety analysis after drop tests according to IAEA-regulations as well as after 1 m-drops at the storage site were confirmed by means of a test programme using a scale model. The fabrication technology has been tested with help of a half scale cask model. The model has been prefabricated in Russia and completed in Germany. It has been shown that the CONSTOR cask can be fabricated in an effective and economic way. (authors)

  2. A concept for the modernization of underground mining master maps based on the enrichment of data definitions and spatial database technology

    Directory of Open Access Journals (Sweden)

    Krawczyk Artur

    2018-01-01

    Full Text Available In this article, topics regarding the technical and legal aspects of creating digital underground mining maps are described. Currently used technologies and solutions for creating, storing and making digital maps accessible are described in the context of the Polish mining industry. Also, some problems with the use of these technologies are identified and described. One of the identified problems is the need to expand the range of mining map data provided by survey departments to other mining departments, such as ventilation maintenance or geological maintenance. Three solutions are proposed and analyzed, and one is chosen for further analysis. The analysis concerns data storage and making survey data accessible not only from paper documentation, but also directly from computer systems. Based on enrichment data, new processing procedures are proposed for a new way of presenting information that allows the preparation of new cartographic representations (symbols of data with regard to users’ needs.

  3. 46 CFR 154.702 - Refrigerated carriage.

    Science.gov (United States)

    2010-10-01

    ... Pressure and Temperature Control § 154.702 Refrigerated carriage. (a) Each refrigeration system must: (1) Have enough capacity to maintain the cargo vapor pressure in each cargo tank served by the system below... the purpose of this section, a “refrigeration unit” includes a compressor and its motors and controls...

  4. Simulation of absorption refrigeration system for automobile application

    Directory of Open Access Journals (Sweden)

    Ramanathan Anand

    2008-01-01

    Full Text Available An automotive air-conditioning system based on absorption refrigeration cycle has been simulated. This waste heat driven vapor absorption refrigeration system is one alternate to the currently used vapour compression refrigeration system for automotive air-conditioning. Performance analysis of vapor absorption refrigeration system has been done by developing a steady-state simulation model to find the limitation of the proposed system. The water-lithium bromide pair is used as a working mixture for its favorable thermodynamic and transport properties compared to the conventional refrigerants utilized in vapor compression refrigeration applications. The pump power required for the proposed vapor absorption refrigeration system was found lesser than the power required to operate the compressor used in the conventional vapor compression refrigeration system. A possible arrangement of the absorption system for automobile application is proposed.

  5. Combined heat and power generation with exhaust-heated two-stage absorption refrigerator. Performance of a pilot installation with a refrigeration capacity of 350 kW; Kraft-Waerme-Kaelte-Kopplung mit Abgas-Beheizter zweistufiger Absorptionskaeltemaschine. Betriebserfahrungen einer Pilotinstallation mit 350 kW Kaelteleistung

    Energy Technology Data Exchange (ETDEWEB)

    Plura, S.; Baumeister, D.; Koeberle, T.; Radspieler, M.; Schweigler, C. [Bayerisches Zentrum fuer Angewandte Energieforschung e.V. (ZAE Bayern), Garching (Germany)

    2007-07-01

    A new system concept for higher efficiency of cogeneration systems is developed in which a cogeneration unit is combined with a two-stage absorption refrigerator, and the waste heat of the cogeneration unit is directly passed on into the regenerator of the absorption refrigerator. The higher temperature level of the waste heat makes it possible to use a two-stage absorption cycle for higher energy efficiency. For simultaneous utilisation of low-temperature heat, the two-stage cycle is combined with a one-stage cycle for additional heat supply at a lower temperature level so that the exhaust of a typical cogeneration unit will be cooled to about 120 degC. At the same time, further waste heat of the cogeneration unit will be transferred to the heat pump via a hot water circuit. This concept with a combined single-stage and two-stage absorption circuit is referred to as a double-effect/single-effect circuit. The new system is used for energy supply in a spa, where the two-stage absorption refrigerator cools the water used for swimming pool cleaning with a refrigerating capacity of 350 kW and provides low-temperature heat for swimming pool heating with a capacity of 700 kW. (orig.)

  6. Next Generation Refrigeration Lubricants for Low Global Warming Potential/Low Ozone Depleting Refrigeration and Air Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    Hessell, Edward

    2013-12-31

    The goal of this project is to develop and test new synthetic lubricants that possess high compatibility with new low ozone depleting (LOD) and low global warming potential (LGWP) refrigerants and offer improved lubricity and wear protection over current lubricant technologies. The improved compatibility of the lubricants with the refrigerants, along with improved lubricating properties, will resulted in lower energy consumption and longer service life of the refrigeration systems used in residential, commercial and industrial heating, ventilating and air-conditioning (HVAC) and refrigeration equipment.

  7. Improving elasticity and hydroinsulation of supports in an explosives storage room as well as adaptation of its parts for temporary storage room during construction of the Czeczott black coal mine

    Energy Technology Data Exchange (ETDEWEB)

    Janusz, E; Perun, S

    1986-05-01

    Design and construction are discussed of an explosives storage room in sandstone strata at 500 m depth in the Czeczott mine. The storage room has a capacity of 3000 kg of explosives, a volume of 5932 m/sup 3/ and consists of 7 storage chambers. Design of supports and liners was aimed at increasing their elasticity and reducing water hazards. Support system consists of the following elements: LP arched steel supports, a 30-40 cm thick layer of slag, a waterproof layer of textiles with a rubber cover, brick liners 40 cm thick. The roof zone of the brick liners is covered by 2 layers of waterproof mortar. Perforated pipes are installed in the slag layer close to the floor. Use of the slag layer increases elasticity of the support system; waterproof textiles, rubber, waterproof mortar and perforated pipes eliminate water hazards as well as hazards associated with stray currents. Design of the explosive storage room is shown in 5 schemes.

  8. Effects of ambient exposure, refrigeration, and icing on Vibrio vulnificus and Vibrio parahaemolyticus abundances in oysters.

    Science.gov (United States)

    Jones, J L; Lydon, K A; Kinsey, T P; Friedman, B; Curtis, M; Schuster, R; Bowers, J C

    2017-07-17

    Vibrio vulnificus (Vv) and V. parahaemolyticus (Vp) illnesses are typically acquired through the consumption of raw molluscan shellfish, particularly oysters. As Vibrio spp. are naturally-occurring bacteria, one means of mitigation of illness is achieved by limiting post-harvest growth. In this study, effects of ambient air storage, refrigeration, and icing of oysters on Vibrio spp. abundances were examined at two sites in Alabama (AL) [Dog River (DR) and Cedar Point (CP)] and one site in Delaware Bay, New Jersey (NJ). As the United States shellfish program recommendations include testing for total these organisms and gene targets, Vv and total (tlh) and pathogenic (tdh+ and trh+) Vp were enumerated from samples using MPN-real-time-PCR approaches. Mean Vv and Vp abundances in oysters from AL-DR were lowest in immediately iced samples (2.3 and -0.1 log MPN/g, respectively) and highest in the 5h ambient then refrigerated samples (3.4 and 0.5 log MPN/g, respectively). Similarly, in AL-CP Vv and Vp mean levels in oysters were lowest in immediately iced samples (3.6 and 1.2 log MPN/g, respectively) and highest in 5h ambient then refrigerated samples (5.1 and 3.2 log MPN/g, respectively). Mean levels of pathogenic Vp from AL sites were frequently below the limit of detection (oysters were highest in samples which were held for 7h in the shade (5.3 and 4.8 log MPN/g, respectively). Mean pathogenic Vp levels in oysters at initial harvest were also highest in oysters 7h in the shade (2.1 and 2.2 log MPN/g for tdh+ and trh+ Vp). Regardless of sampling location, Vibrio spp. levels were generally significantly (poysters exposed to 5h of air storage compared to the initially harvested samples. In addition, the data demonstrated that the use of layered ice resulted in lower Vibrio spp. levels in oysters, compared to those that were refrigerated post-harvest. These results suggest vibriosis risk can be mitigated by shorter storage times and more rapid cooling of oysters

  9. An Evaluation of the Environmental Impact of Different Commercial Supermarket Refrigeration Systems Using Low Global Warming Potential Refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Beshr, Mohamed [University of Maryland, College Park; Aute, Vikrant [University of Maryland, College Park; Abdelaziz, Omar [ORNL; Fricke, Brian A [ORNL; Radermacher, Reinhard [University of Maryland, College Park

    2014-01-01

    Commercial refrigeration systems consumed 1.21 Quads of primary energy in 2010 and are known to be a major source for refrigerant charge leakage into the environment. Thus, it is important to study the environmental impact of commercial supermarket refrigeration systems and improve their design to minimize any adverse impacts. The system s Life Cycle Climate Performance (LCCP) was presented as a comprehensive metric with the aim of calculating the equivalent mass of carbon dioxide released into the atmosphere throughout its lifetime, from construction to operation and destruction. In this paper, an open source tool for the evaluation of the LCCP of different air-conditioning and refrigeration systems is presented and used to compare the environmental impact of a typical multiplex direct expansion (DX) supermarket refrigeration systems based on three different refrigerants as follows: two hydrofluorocarbon (HFC) refrigerants (R-404A, and R-407F), and a low global warming potential (GWP) refrigerant (N-40). The comparison is performed in 8 US cities representing different climates. The hourly energy consumption of the refrigeration system, required for the calculation of the indirect emissions, is calculated using a widely used building energy modeling tool (EnergyPlus). A sensitivity analysis is performed to determine the impact of system charge and power plant emission factor on the LCCP results. Finally, we performed an uncertainty analysis to determine the uncertainty in total emissions for both R-404A and N-40 operated systems. We found that using low GWP refrigerants causes a considerable drop in the impact of uncertainty in the inputs related to direct emissions on the uncertainty of the total emissions of the system.

  10. Effects of diet, packaging, and irradiation on protein oxidation, lipid oxidation, and color of raw broiler thigh meat during refrigerated storage.

    Science.gov (United States)

    Xiao, S; Zhang, W G; Lee, E J; Ma, C W; Ahn, D U

    2011-06-01

    This study was designed to evaluate the effects of dietary treatment, packaging, and irradiation singly or in combination on the oxidative stability of broiler chicken thigh meat. A total of 120 four-week-old chickens were divided into 12 pens (10 birds/pen), and 4 pens of broilers were randomly assigned to a control oxidized diet (5% oxidized oil) or an antioxidant-added diet [500 IU of vitamin E + 200 mg/kg of butylated hydroxyanisole (BHA)] and fed for 2 wk. After slaughter, thigh meats were separated, ground, packaged in either oxygen-permeable or oxygen-impermeable vacuum bags, and irradiated at 0 or 3 kGy. Lipid oxidation (TBA-reactive substances), protein oxidation (carbonyl), and color of the meat were measured at 1, 4, and 7 d of refrigerated storage. The lipid and protein oxidation of thigh meats from birds fed the diet supplemented with antioxidants (vitamin E + BHA) was significantly lower than the lipid and protein oxidation of birds fed the control diet, whereas the lipid and protein oxidation of broilers fed the oxidized oil diet was higher than that of birds fed the control diet. Vacuum packaging slowed, but irradiation accelerated, the lipid and protein oxidation of thigh meat during storage. Dietary antioxidants (vitamin E + BHA) and irradiation treatments showed a stronger effect on lipid oxidation than on protein oxidation. A significant correlation between lipid and protein oxidation in meat was found during storage. Dietary supplementation of vitamin E + BHA and the irradiation treatment increased the lightness and redness of thigh meat, respectively. It is suggested that appropriate use of dietary antioxidants in combination with packaging could be effective in minimizing oxidative changes in irradiated raw chicken thigh meat.

  11. Know-how of refrigerating technology. 2. completely rev. ed. Fachwissen Kaeltetechnik fuer die industrielle und gewerbliche Praxis; Eine Einfuehrung mit Aufgaben und Loesungen

    Energy Technology Data Exchange (ETDEWEB)

    Reisner, K.

    1994-01-01

    This specialized book is based on causes on refrigerating technology held in preparation of apprentices and master candidates for their examinations and on training seminars for operators and users. It bebins with a generalised presentation intended to enable the constructor of a plant to develop an initial concept. The author then explains step by step from the basics of thermodynamics over to fluid mechanics the entire spectrum of subdisciplines that make up refrigerating technology: cooling circuit, compression refrigerants, heat exchange, regulators, piping, required cooling capacity. Practice-oriented calculation models for all fields of refrigerating technology also make the work a valuable reference book. (BWI)

  12. User evaluation of photovoltaic-powered vaccine refrigerator/freezer systems

    Science.gov (United States)

    Ratajczak, Anthony F.

    1987-03-01

    The NASA Lewis Research Center has concluded a project to develop and field test photovoltaic-powered refrigerator/freezers for vaccine storage in remote areas of developing countries. As a conclusion to this project, questionnaires were sent to the in-country administrators for each test site probing user acceptance of the systems and attitudes regarding procurement of additional systems. Responses indicate that the systems had a positive effect on the local communities, that they made a positive impression on the local health authorities, and that system cost and scarcity of funds are the major barriers to procurements of additional systems.

  13. Swedish mines. Underground exploitation methods

    International Nuclear Information System (INIS)

    Paucard, A.

    1960-01-01

    Between 1949 and 1957, 10 engineers of the Mining research and exploitation department of the CEA visited 17 Swedish mines during 5 field trips. This paper presents a compilation of the information gathered during these field trips concerning the different underground mining techniques used in Swedish iron mines: mining with backfilling (Central Sweden and Boliden mines); mining without backfilling (mines of the polar circle area). The following techniques are described successively: pillar drawing and backfilled slices (Ammeberg, Falun, Garpenberg, Boliden group), sub-level pillar drawing (Grangesberg, Bloettberget, Haeksberg), empty room and sub-level pillar drawing (Bodas, Haksberg, Stripa, Bastkarn), storage chamber pillar drawing (Bodas, Haeksberg, Bastkarn), and pillar drawing by block caving (ldkerberget). Reprint of a paper published in Revue de l'Industrie Minerale, vol. 41, no. 12, 1959 [fr

  14. Cold storage facilities in the home. A complex question; Kotitalouden kylmaesaeilytys on monitahoinen kysymys

    Energy Technology Data Exchange (ETDEWEB)

    Marjomaa, T. [Work Efficiency Inst., Helsinki (Finland)

    1997-08-01

    Cold storage plays a central station in the management of food matters in Banish household. The need for freezing becomes especially emphasised in preserving berries, vegetables and game. The matter of how much and what kind of a cold storage is needed varies from household to household and according to people`s stage in life - even according to the days of the week. The average Banish household uses an average of 1-4 refrigeration devices. Most of them are switched on throughout the year. Despite the low connected loads, the yearly consumption of electricity is significant. The daily (24 h) power consumption of freezer-refrigerators included in TTS-Institute`s study in 1995-1996 was 1.13-2.13 kWh with the corresponding annual consumption then being 412-777 kWh. The methods provided by product development have made it possible to improve the energy-saving effects of refrigeration devices. For instance the structural properties of devices have.been developed: these include thicker insulation and the structure of compressors. condensers and evaporators. The TTS-Institute has proposed product development ideas. e.g. on the convertibility of cold-storage facilities. (orig.)

  15. Mining concepts of health responsibility using text mining and exploratory graph analysis.

    Science.gov (United States)

    Kjellström, Sofia; Golino, Hudson

    2018-05-24

    Occupational therapists need to know about people's beliefs about personal responsibility for health to help them pursue everyday activities. The study aims to employ state-of-the-art quantitative approaches to understand people's views of health and responsibility at different ages. A mixed method approach was adopted, using text mining to extract information from 233 interviews with participants aged 5 to 96 years, and then exploratory graph analysis to estimate the number of latent variables. The fit of the structure estimated via the exploratory graph analysis was verified using confirmatory factor analysis. Exploratory graph analysis estimated three dimensions of health responsibility: (1) creating good health habits and feeling good; (2) thinking about one's own health and wanting to improve it; and 3) adopting explicitly normative attitudes to take care of one's health. The comparison between the three dimensions among age groups showed, in general, that children and adolescents, as well as the old elderly (>73 years old) expressed ideas about personal responsibility for health less than young adults, adults and young elderly. Occupational therapists' knowledge of the concepts of health responsibility is of value when working with a patient's health, but an identified challenge is how to engage children and older persons.

  16. Operations and Maintenance Concept Plan for the Immobilized High Level Waste (IHLW) Interim Storage Facility

    Energy Technology Data Exchange (ETDEWEB)

    JANIN, L.F.

    2000-08-30

    This O&M Concept looks at the future operations and maintenance of the IHLW/CSB interim storage facility. It defines the overall strategy, objectives, and functional requirements for the portion of the building to be utilized by Project W-464. The concept supports the tasks of safety basis planning, risk mitigation, alternative analysis, decision making, etc. and will be updated as required to support the evolving design.

  17. Operations and Maintenance Concept Plan for the Immobilized High-Level Waste (IHLW) Interim Storage Facility

    International Nuclear Information System (INIS)

    JANIN, L.F.

    2000-01-01

    This OandM Concept looks at the future operations and maintenance of the IHLW/CSB interim storage facility. It defines the overall strategy, objectives, and functional requirements for the portion of the building to be utilized by Project W-464. The concept supports the tasks of safety basis planning, risk mitigation, alternative analysis, decision making, etc. and will be updated as required to support the evolving design

  18. Conception of a heat storage system for household applications. Category: New product innovations

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Thomas [Leuphana Univ. Lueneburg (Germany); Rammelberg, Holger U.; Roennebeck, Thomas [and others

    2012-07-01

    Almost 90% of the energy consumption of private households in Germany is used for heating. Thus, an efficient, sustainable and reliable heat management is one of the main challenges in the future. Heat storage will become a key technology when considering the daily, weekly, seasonal and unpredictable fluctuations of energy production with renewables. The storage of heat is much more volume- and energy-efficient as well as more economical than electricity storage. However, transport of heat over long distances is coupled with high losses, compared with electricity transport. Therefore, we propose the use of micro CHP in combination with volume-efficient and nearly loss-free heat storage to counteract electricity fluctuations. Focus of this contribution the conception of the large-scale project ''Thermal Battery'', funded by the European Union and the Federal State of Lower Saxony. The underlying principle is the utilization of reversible thermochemical reactions, such as dehydration and rehydration of salt hydrates for heat storage. The main goal is the development of a prototypical storage tank, which is capable of storing 80 kWh of heat with a system volume of less than 1 m{sup 3}. Importantly, the Vattenfall New Energy Services as a collaboration partner will support the development of an application-oriented heat storage device. This project is being carried out by an interdisciplinary team of engineers, chemists, physicists and environmental scientists.

  19. Study of the effects of gamma radiation on the microbiological quality, lipid oxidation and sensory properties of mechanically deboned chicken meat throughout refrigerated and frozen storage; Estudo dos efeitos da radiacao gama sobre a qualidade microbiologica, a oxidacao lipidica e as propriedades sensoriais da carne mecanicamente separada de frango, armazenada refrigerada e congelada

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Heliana de Azevedo

    2002-07-01

    Mechanically deboned chicken meat (MDCM) is widely used in traditional meat products such as sausages. The proceed of mechanical separation results in grinding of the bones, liberating the marrow and rupturing cells, thus making the MDCM a favorable medium for biochemical reactions and microbiological growth. Irradiation using a Co{sup 60} source is one of the processes which has been developed aimed at reducing contamination by spoilage and pathogenic microorganisms in foods. The main advantages of food irradiation are the possibilities of treating the already packaged products at refrigerated and frozen temperatures, ideal for a highly perishable product such as MDCM, which, being a ground, easily spoiled product, requires rapid cooling followed by freezing, immediately after processing. Processing with ionizing radiation results in chemical alterations in the food, including the production of volatile compounds and free radicals. Irradiation of meat in the frozen state reduces or eliminates the negative sensory effects of this process. In this context, this study aimed at evaluating the effects of gamma radiation at doses of 3.0 and 4.0 kGy, on the microbiological quality, lipid oxidation and sensory properties of MDCM, at the refrigerated (2 {+-} 1 deg C) and frozen (-18 {+-} 1 deg C) storage, The results showed that irradiation increased the shelf life of this raw material when stored under refrigeration, as compared to non-irradiated samples. Since doses of 3.0 kGy produced increases in the shelf life of refrigerated MDCM equal or greater than those produced by doses of 4.0 kGy, this dose was considered the most adequate for the irradiation of this raw material. According to the results of microbiological, chemical and sensorial testing in irradiated MDCM samples with doses of 3.0 kGy and 4.0 kGy, the material studied presented conditions that were adequate for human consumption during the 90 days of frozen storage, whereas samples of non-irradiated MDCM were

  20. Suitability criterion for a refrigerant for use in solar operated sorption refrigerator

    International Nuclear Information System (INIS)

    Tabassum, S.A.; Mir, M.S.

    1996-01-01

    The thermodynamics of a sorption refrigeration cycle has been discussed representing the cycle on a clapeyron digram. The minimum generation temperature required has been determined using the 'd-a' equation which represents the sorption equilibrium of the pair, and Gibbs free energy relation. The mathematical relation developed provides a totally new basis for determination of suitability of a particular refrigerant. (author)

  1. Suitability criterion for a refrigerant for use in solar operated sorption refrigerator

    Energy Technology Data Exchange (ETDEWEB)

    Tabassum, S A; Mir, M S [University of Engineering and Technology, Lahore (Pakistan). Dept. of Mechanical Engineering

    1996-06-01

    The thermodynamics of a sorption refrigeration cycle has been discussed representing the cycle on a clapeyron digram. The minimum generation temperature required has been determined using the `d-a` equation which represents the sorption equilibrium of the pair, and Gibbs free energy relation. The mathematical relation developed provides a totally new basis for determination of suitability of a particular refrigerant. (author).

  2. Alternative utilization of underground spaces with abandoned mine openings

    Energy Technology Data Exchange (ETDEWEB)

    Chung, So Keul; Cho, Won Jai; Han, Kong Chang; Choi, Sung Oong [Korea Institute of Geology Mining and Materials, Taejon (Korea)

    1998-12-01

    Utilization of the openings of the abandoned mines could be planned by the principal parameters such as location and geotechnical impact. The local governments have not only to lead the each stage of the utilization project from the very beginning of conceptual design up to the construction stage, but also to promote the project for the development of public purpose. The possible tentative candidates for the utilization of the abandoned mine openings which are supported by the local governments could be summarized as follows. a. The Gahak mine of Kwangmyung, Kyunggi: The mine caverns which have been served as the storage of the pickled fishes, could be reexcavated by taking into consideration the geotechnical parameters for the public use such as: 1) Training center for the youth, 2) Fermentation and storehouse of marine products, 3) Sightseeing resort, 4) Sports and leisure complex, 5) Underground parking lot, 6) Underground shopping mall and chilled room storage, 7) Library, concert hall and museum. b. Hamtae mine of Taebaek, Kangwon: The Hambaek main haulage way and its shaft should be investigated in detail in order to find out a possible use as the underground challenging park of the coal mining operation. c. Mines of Boryung and Hongsung, Chungnam: Lots of mine caverns have been used as the storehouse for the pickled shrimp. However, they have to be promoted to a large scale industries. d. Imgok mine of Kwangju and Palbong mine of Jeongeup, Chunbuk: Mine caverns which have been used as the storehouse of pickles, need a detailed investigation for alternative promotion. e. Yongho mine of Pusan Dalsung mine of Taegu: Both of the mines are located near metropolitan communities. Reconstruction of the old mine caverns of the Yongho mine is highly recommended for a public use. The caverns of the Dalsung mine could be utilized as the storage facilities. Detailed geotechnical survey and sit investigation could be suggested to design the recommended facilities for both

  3. SIMULATION OF NON-AZEOTROPIC REFRIGERANT MIXTURES FOR USE IN A DUAL-CIRCUIT REFRIGERATOR/FREEZER WITH COUNTERCURRENT HEAT EXCHANGES

    Science.gov (United States)

    The paper discusses a refrigerator/freezer (RF) system that has two complete and independent refrigeration cycles for the two compartments. It uses a non-azeotropic refrigerant mixture (NARM) in each cycle and countercurrent heat exchangers throughout. This RF is housed in a stan...

  4. Maximizing the energy storage performance of phase change thermal storage systems

    Energy Technology Data Exchange (ETDEWEB)

    Amin, N.A.M.; Bruno, F.; Belusko, M. [South Australia Univ., Mawson Lakes, South Australia (Australia). Inst. for Sustainable Systems and Technologies

    2009-07-01

    The demand for electricity in South Australia is highly influenced by the need for refrigeration and air-conditioning. An extensive literature review has been conducted on the use of phase change materials (PCMs) in thermal storage systems. PCMs use latent heat at the solid-liquid phase transition point to store thermal energy. They are considered to be useful as a thermal energy storage (TES) material because they can provide much higher energy storage densities compared to conventional sensible thermal storage materials. This paper reviewed the main disadvantages of using PCMs for energy storage, such as low heat transfer, super cooling and system design issues. Other issues with PCMs include incongruence and corrosion of heat exchanger surfaces. The authors suggested that in order to address these problems, future research should focus on maximizing heat transfer by optimizing the configuration of the encapsulation through a parametric analysis using a PCM numerical model. The effective conductivity in encapsulated PCMs in a latent heat thermal energy storage (LHTES) system can also be increased by using conductors in the encapsulation that have high thermal conductivity. 47 refs., 1 tab., 1 fig.

  5. Polyhalogenated hydrocarbon refrigerants and refrigerant oils colored with fluorescent dyes and method for their use as leak detectors

    Energy Technology Data Exchange (ETDEWEB)

    Parekh, M.

    1988-07-19

    A leak detectable refrigeration composition is described comprising: (A) a refrigeration liquid selection from the group consisting of: (1) a polyhalogenated hydrocarbon refrigerant; (2) a refrigeration oil selected from the group consisting of naphthenic oils, paraffinic oils, alkylated benzenes, silicones, polyglycols, diesters or triesters of dicarboxylic or tricarboxylic acids, and polyalkyl silicate oils, and (3) a mixture of A(1) and A(2), and (B) a fluorescent dye compound or composition comprising the dye selected from the group consisting of: (1) a fluorescent dye selected from the group consisting of perylene, naphthoxanthene, monocyclic aromatic compounds having an organometallic compound, (2) a solution of fluorescent dye in a solvent, and (3) a mixture of B(1) and B(2). The fluorescent dye compound or composition is soluble in the refrigeration liquid. The concentration of the dye being at least 0.001 grams per 100 grams of the refrigeration liquid.

  6. Optimization of operation of energy supply systems with co-generation and absorption refrigeration

    Directory of Open Access Journals (Sweden)

    Stojiljković Mirko M.

    2012-01-01

    Full Text Available Co-generation systems, together with absorption refrigeration and thermal storage, can result in substantial benefits from the economic, energy and environmental point of view. Optimization of operation of such systems is important as a component of the entire optimization process in pre-construction phases, but also for short-term energy production planning and system control. This paper proposes an approach for operational optimization of energy supply systems with small or medium scale co-generation, additional boilers and heat pumps, absorption and compression refrigeration, thermal energy storage and interconnection to the electric utility grid. In this case, the objective is to minimize annual costs related to the plant operation. The optimization problem is defined as mixed integer nonlinear and solved combining modern stochastic techniques: genetic algorithms and simulated annealing with linear programming using the object oriented “ESO-MS” software solution for simulation and optimization of energy supply systems, developed as a part of this research. This approach is applied to optimize a hypothetical plant that might be used to supply a real residential settlement in Niš, Serbia. Results are compared to the ones obtained after transforming the problem to mixed 0-1 linear and applying the branch and bound method.

  7. High temperature refrigerator

    International Nuclear Information System (INIS)

    Steyert, W.A. Jr.

    1978-01-01

    A high temperature magnetic refrigerator is described which uses a Stirling-like cycle in which rotating magnetic working material is heated in zero field and adiabatically magnetized, cooled in high field, then adiabatically demagnetized. During this cycle the working material is in heat exchange with a pumped fluid which absorbs heat from a low temperature heat source and deposits heat in a high temperature reservoir. The magnetic refrigeration cycle operates at an efficiency 70% of Carnot

  8. Refrigerant charge management in a heat pump water heater

    Science.gov (United States)

    Chen, Jie; Hampton, Justin W.

    2014-06-24

    Heat pumps that heat or cool a space and that also heat water, refrigerant management systems for such heat pumps, methods of managing refrigerant charge, and methods for heating and cooling a space and heating water. Various embodiments deliver refrigerant gas to a heat exchanger that is not needed for transferring heat, drive liquid refrigerant out of that heat exchanger, isolate that heat exchanger against additional refrigerant flowing into it, and operate the heat pump while the heat exchanger is isolated. The heat exchanger can be isolated by closing an electronic expansion valve, actuating a refrigerant management valve, or both. Refrigerant charge can be controlled or adjusted by controlling how much liquid refrigerant is driven from the heat exchanger, by letting refrigerant back into the heat exchanger, or both. Heat pumps can be operated in different modes of operation, and segments of refrigerant conduit can be interconnected with various components.

  9. Technological highwall mining

    Energy Technology Data Exchange (ETDEWEB)

    Davison, I. [Highwall Systems (United States)

    2006-09-15

    The paper explores the issues facing highwall mining. Based in Chilhowie, Virginia, American Highwall Systems has developed a highwall mining system that will allow the mining of coal seams from 26 in to 10 ft in thickness. The first production model, AH51, began mining in August 2006. Technologies incorporated into the company's mining machines to improve the performance, enhance the efficiency, and improve the reliability of the highwall mining equipment incorporate technologies from many disciplines. Technology as applied to design engineering, manufacturing and fabrication engineering, control and monitoring computer hardware and software has played an important role in the evolution of the American Highwall Systems design concept. 5 photos.

  10. Thermoeconomic analysis of a solar enhanced energy storage concept based on thermodynamic cycles

    International Nuclear Information System (INIS)

    Henchoz, Samuel; Buchter, Florian; Favrat, Daniel; Morandin, Matteo; Mercangöz, Mehmet

    2012-01-01

    Large scale energy storage may play an increasingly important role in the power generation and distribution sector, especially when large shares of renewable energies will have to be integrated into the electrical grid. Pumped-hydro is the only large scale storage technology that has been widely used. However the spread of this technology is limited by geographic constraints. In the present work, a particular implementation of a storage concept based on thermodynamic cycles, invented by ABB Switzerland ltd. Corporate Research, has been analysed thermoeconomically. A variant using solar thermal collectors is presented. It benefits from the synergy between daily variations in solar irradiance and in electricity demand. This results in an effective increase of the electric energy storage efficiency. A steady state multi-objective optimization of a 50 MW plant was done; minimizing the investment costs and maximizing the energy storage efficiency. Several types of cold storage substances have been implemented in the formulation and two different types of solar collector were investigated. A storage efficiency of 57% at a cost of 1200 USD/kW was calculated for an optimized plant using solar energy. Finally, a computation of the behaviour of the plant along the year showed a yearly availability of 84.4%. -- Highlights: ► A variant of electric energy storage based on thermodynamic cycles is presented. ► It uses solar collectors to improve the energy storage efficiency. ► An optimization minimizing capital cost and maximizing energy storage efficiency, was carried out. ► Capital costs lie between 982 and 3192 USD/kW and efficiency between 43.8% and 84.4%.

  11. The effects of temperature on the crystalline properties and resistant starch during storage of white bread.

    Science.gov (United States)

    Sullivan, William R; Hughes, Jeff G; Cockman, Russell W; Small, Darryl M

    2017-08-01

    Resistant starch (RS) can form during storage of foods, thereby bestowing a variety of potential health benefits. The purpose of the current study has been to determine the influence of storage temperature and time on the crystallinity and RS content of bread. Loaves of white bread were baked and stored at refrigeration, frozen and room temperatures with analysis over a period of zero to seven days. RS determination and X-ray diffraction (XRD) were used to evaluate the influence of storage temperature and time on total crystallinity and RS content. The rate of starch recrystallisation was affected by storage temperature and time, where refrigeration temperatures accelerated RS formation and total crystallinity more than storage time at both frozen and room temperature. A strong statistical model has been established between RS formation in bread and XRD patterns, having a 96.7% fit indicating the potential of XRD to measure RS concentrations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Environmentally benign working pairs for adsorption refrigeration

    International Nuclear Information System (INIS)

    Cui Qun; Tao Gang; Chen Haijun; Guo Xinyue; Yao Huqing

    2005-01-01

    This paper begins from adsorption working pairs: water and ethanol were selected as refrigerants; 13x molecular sieve, silica gel, activated carbon, adsorbent NA and NB, proposed by authors, were selected as adsorbents, and the performance of adsorption working pairs in adsorption refrigeration cycle was studied. The adsorption isotherms of adsorbents (NA and NB) were obtained by high-vacuum gravimetric method. Desorption properties of adsorbents were analyzed and compared by thermal analysis method. The performance of adsorption refrigeration was studied on simulation device of adsorption refrigeration cycle. After presentation of adsorption isotherms, the thermodynamic performance for their use in adsorption refrigeration system was calculated. The results show: (1) the maximum adsorption capacity of water on adsorbent NA reaches 0.7 kg/kg, and the maximum adsorption capacity of ethanol on adsorbent NB is 0.68 kg/kg, which is three times that of ethanol on activated carbon, (2) the refrigeration capacity of NA-water working pair is 922 kJ/kg, the refrigeration capacity of NB-ethanol is 2.4 times that of activated carbon-methanol, (3) as environmental friendly and no public hazard adsorption working pair, NA-H 2 O and NB-ethanol can substitute activated carbon-methanol in adsorption refrigeration system using low-grade heat source

  13. Mountain Plains Learning Experience Guide: Heating, Refrigeration, & Air Conditioning.

    Science.gov (United States)

    Carey, John

    This Heating, Refrigeration, and Air Conditioning course is comprised of eleven individualized units: (1) Refrigeration Tools, Materials, and Refrigerant; (2) Basic Heating and Air Conditioning; (3) Sealed System Repairs; (4) Basic Refrigeration Systems; (5) Compression Systems and Compressors; (6) Refrigeration Controls; (7) Electric Circuit…

  14. 30 CFR 77.209 - Surge and storage piles.

    Science.gov (United States)

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Surface... a reclaiming area or in any other area at or near a surge or storage pile where the reclaiming...

  15. 2014 German refrigeration and air conditioning meeting. Proceedings

    International Nuclear Information System (INIS)

    2014-01-01

    The proceedings of the 2014 German refrigeration and air conditioning meeting contain contributions on the following topics: cryotechnology, fundamentals and materials for the refrigeration and heat pump technology, devices and components for the refrigeration and heat pump technology, applications of refrigeration technologies, air conditioning technology and heat pump applications, cryotechnology in biology and medicine, heat transfer and ventilation, guidelines and legal topics, refrigerant fluid - oil mixtures, control and surveillance, simulation and control, ambient air.

  16. Concept for Underground Disposal of Nuclear Waste

    Science.gov (United States)

    Bowyer, J. M.

    1987-01-01

    Packaged waste placed in empty oil-shale mines. Concept for disposal of nuclear waste economically synergistic with earlier proposal concerning backfilling of oil-shale mines. New disposal concept superior to earlier schemes for disposal in hard-rock and salt mines because less uncertainty about ability of oil-shale mine to contain waste safely for millenium.

  17. Control of the Tevatron Satellite Refrigeration system

    International Nuclear Information System (INIS)

    Theilacker, J.; Chapman, L.; Gannon, J.; Hentges, M.; Martin, M.; Rode, C.H.; Zagel, J.

    1984-01-01

    This chapter describes a computerized control system for 24 satellite refrigerators which cool a six kilometer ring of superconducting magnets. The control system consists of 31 independent microprocessors operating over 400 servo loops, and a central computer system which provides monitoring, alarms, logging and changing of parameters. Topics considered include pressure measurement, flow measurement, temperature measurement, gas analysis, control valves, expansion engine controllers, and control loops. Each refrigerator has 12 active microprocessor based control loops which tune the refrigerator to one of its four operating modes: satellite, liquefier, refrigerator, and stand-by. It is suggested that optimizing the refrigerator control loops and quench recovery scheme will minimize the accelerator down time

  18. Performance characteristics of a quantum Diesel refrigeration cycle

    International Nuclear Information System (INIS)

    He Jizhou; Wang Hao; Liu Sanqiu

    2009-01-01

    The Diesel refrigeration cycle using an ideal quantum gas as the working substance is called quantum Diesel refrigeration cycle, which is different from Carnot, Ericsson, Brayton, Otto and Stirling refrigeration cycles. For ideal quantum gases, a corrected equation of state, which considers the quantum behavior of gas particles, is used instead of the classical one. The purpose of this paper is to investigate the effect of quantum gas as the working substance on the performance of a quantum Diesel refrigeration cycle. It is found that coefficients of performance of the cycle are not affected by the quantum degeneracy of the working substance, which is the same as that of the classical Diesel refrigeration cycle. However, the refrigeration load is different from those of the classical Diesel refrigeration cycle. Lastly, the influence of the quantum degeneracy on the performance characteristics of the quantum Diesel refrigeration cycle operated in different temperature regions is discussed

  19. The mining methods at the Fraisse mine

    International Nuclear Information System (INIS)

    Heurley, P.; Vervialle, J.P.

    1985-01-01

    The Fraisse mine is one of the four underground mines of the La Crouzille mining divisions of Cogema. Faced with the necessity to mechanize its workings, this mine also had to satisfy a certain number of stringent demands. This has led to concept of four different mining methods for the four workings at present in active operation at this pit, which nevertheless preserve the basic ideas of the methods of top slicing under concrete slabs (TSS) or horizontal cut-and-fill stopes (CFS). An electric scooptram is utilized. With this type of vehicle the stringent demands for the introduction of means for fire fighting and prevention are reduced to a minimum. Finally, the dimensions of the vehicles and the operation of these methods result in a net-to-gross tonnages of close to 1, i.e. a maximum output, combined with a minimum of contamination [fr

  20. The effect of radiation on the storage of fish

    International Nuclear Information System (INIS)

    Ghadi, S.V.; Madhavan, V.N.; Kumta, U.S.; Lewis, N.F.

    1976-01-01

    Fresh fish spoils rapidly at +- 0 0 to + 2 0 C, and produces considerable quantities of ammonia. It is known that ammonia production is reduced if fish is heated before processing. Radiation experiments were carried out to see whether the storage stability of fresh fish could be improved without cooking it. Radiation with 100 to 500 Krad or steam cooking for 3 to 5 minutes did not improve storage stability. Only combined treatment with steam and low doses (100 Krad) of gamma rays lengthened refrigerated storage life. (orig.) [de

  1. Reformulating the calculation of mining privileges for medium and large mining

    Directory of Open Access Journals (Sweden)

    Pedro Franco Concha

    2016-01-01

    Full Text Available Throughout this paper those technical and accounting concepts of the Law of mining privileges that generate ambiguity and incongruity for businesses has been analyzed and identified. For this reason, we have developed a proposal amending the calculation of mining privileges based on two main aspects: (i terminology used in the law and (ii establishment of income before retribution to stakholders and taxes as a basis for calculating privileges. As a result, it was established as an object of study for all mining companies paying privileges; however, for purposes of the investigation three representative mining companies of medium and large mining were selected. Later interviews were arranged with financial and tax managers of the companies mentioned above as well as experts in the field of mining privileges; it was concluded that the concepts of "cost" and "corresponding fiscal year" mentioned in the Law generated ambiguities, inconsistencies and accounting distortions. Also, mining companies and experts agreed that the current basis for the calculation of the privileges is not adequate for the mining sector since it does not reflect the financial situation of companies. Therefore, a proposal for reformulation of the applied priviously and a new basis for calculating the mining privileges based on the cost of sales is made; since, in the cost of sales is found what Kieso and Weygandt (1999 denominated as "the price paid for the right to seek and find a hidden Natural resources, or paid by a source already discovered"

  2. ARTI refrigerant database. Quarterly report, March--May 1997

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1997-05-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information an older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date.

  3. Methods for storage and disposal of residues from wastewater treatment of former uranium mining and milling facilities in Germany

    Energy Technology Data Exchange (ETDEWEB)

    Larue, J; Weiss, D [Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS) mbH, Berlin (Germany); Kiessig, G [WISMUTGmbH, Chemnitz (Germany)

    2002-02-01

    In connection with the flooding of uranium mines in Saxony and Thuringia, there are contaminated pit waters that must be purified before discharge into surface waters. The expected duration of the water purification process until concentrations of natural radionuclides, various heavy metals and arsenic are low enough to allow direct discharge into surface waters amounts to decades . To prevent or minimize the leaching of the contaminants from the sludge of the water treatment in the long term, the contaminants are either transformed into chemical compounds of low solubility or affixed within ion exchange resins. Due to the accumulation of those contaminants during the water processing procedure, the residua must be disposed of for reasons of radiation protection and waste management. A final storage of the residua in accord with nuclear regulatory stipulations is unnecessary because of the contamination levels and also because of the mining origin. The method of residua-storage chosen to be best suited to a particular site has to be based on costs-to-benefit analyses, giving due consideration to the different aspects e.g. radiation and environmental protection, long term safety, form of immobilization, site specific conditions. These methods will be described and illustrated using specific examples of applications. (author)

  4. Methods for storage and disposal of residues from wastewater treatment of former uranium mining and milling facilities in Germany

    International Nuclear Information System (INIS)

    Larue, J.; Weiss, D.; Kiessig, G.

    2002-01-01

    In connection with the flooding of uranium mines in Saxony and Thuringia, there are contaminated pit waters that must be purified before discharge into surface waters. The expected duration of the water purification process until concentrations of natural radionuclides, various heavy metals and arsenic are low enough to allow direct discharge into surface waters amounts to decades . To prevent or minimize the leaching of the contaminants from the sludge of the water treatment in the long term, the contaminants are either transformed into chemical compounds of low solubility or affixed within ion exchange resins. Due to the accumulation of those contaminants during the water processing procedure, the residua must be disposed of for reasons of radiation protection and waste management. A final storage of the residua in accord with nuclear regulatory stipulations is unnecessary because of the contamination levels and also because of the mining origin. The method of residua-storage chosen to be best suited to a particular site has to be based on costs-to-benefit analyses, giving due consideration to the different aspects e.g. radiation and environmental protection, long term safety, form of immobilization, site specific conditions. These methods will be described and illustrated using specific examples of applications. (author)

  5. Scoping report on various salt mines in the United States

    International Nuclear Information System (INIS)

    Jacoby, C.H.

    1977-07-01

    One of the most important factors in isolating the demonstration waste storage site is an adequate number of shafts to insure proper ventilation. Proper ventilation will require that the air exhausted from the storage area pass directly to the upcast air shaft. Those mines reported by this scoping contract generally conform with the two shafts per mine requirement of MESA. Three of the mines reported on have more than two shafts. Several of the mines can have additional shafts drilled in time to meet ERDA's schedule. Rough drilling costs have been cited in the report. From an economic standpoint, it is probable that the larger the mine, the greater the economic impact with regard to any dislocation of production that may be required. In some cases, such as the Retsof Mine and the Cayuga Mine, multiple shafts eliminate the probability of dislocation. Those small tonnage mines such as the Kleer at Grand Saline, Texas; the Hockley Mine near Houston and the Lyons Mine of the American Salt Company might be leased or purchased in their entirety

  6. Optimum operating regimes of common paramagnetic refrigerants

    CERN Document Server

    Wikus, P; Figueroa-Feliciano, E

    2011-01-01

    Adiabatic Demagnetization Refrigerators (ADRs) are commonly used in cryogenic laboratories to achieve subkelvin temperatures. ADRs are also the technology of choice for several space borne instruments which make use of cryogenic microcalorimeters or bolometers {[}1-4]. For these applications, refrigerants with high ratios of cooling capacity to volume, or cooling capacity to mass are usually required. In this manuscript, two charts for the simple selection of the most suitable of several common refrigerants (CAA, CMN, CPA, DGG, FAA, GGG, GLF and MAS) are presented. These graphs are valid for single stage cycles. The selection of the refrigerants is uniquely dependent on the starting conditions of the refrigeration cycle (temperature and magnetic field density) and the desired final temperature. Only thermodynamic properties of the refrigerants have been taken into account, and other important factors such as availability and manufacturability have not been considered. (C) 2011 Elsevier Ltd. All rights reserve...

  7. Design, installation and operating experience of 20 photovoltaic medical refrigerator systems on four continents

    Science.gov (United States)

    Hein, G. F.

    1982-01-01

    The NASA Lewis Research Center in cooperation with the World Health Organization, U.S.A. I.D., the Pan American Health Organization and national government agencies in some developing countries sponsored the installation of twenty photovoltaic powered medical vaccine storage refrigerator-freezer (R/F) systems. The Solar Power Corporation was selected as the contractor to perform the design, development and installation of these twenty units. Solar Power's experiences are described herein.

  8. Heat transport and storage

    International Nuclear Information System (INIS)

    Despois, J.

    1977-01-01

    Recalling the close connections existing between heat transport and storage, some general considerations on the problem of heat distribution and transport are presented 'in order to set out the problem' of storage in concrete form. This problem is considered in its overall plane, then studied under the angle of the different technical choices it involves. The two alternatives currently in consideration are described i.e.: storage in a mined cavity and underground storage as captive sheet [fr

  9. Magnesium mechanical alloys for hydrogen storage

    International Nuclear Information System (INIS)

    Ivanov, E.; Konstanchuk, I.; Stepanov, A.; Boldyrev, V.

    1985-01-01

    Metal hybrides are currently being used to store and handle hydrogen and its isotopes. They are also being tested in hydrogen compressors and in heat energy, refrigerators and in hydrogen and thermal storage devices. Metal hydrides have been proposed as one of the possible media for hydrogen storage to overcome the limitations of other techniques in regard to safety hydrogen weight and volume ration. The suitability of metal hybrides as a hydrogen storage media depends on a number of factors such as storage capacity, reactivity with hydrogen at various pressures and temperatures, and the cost of base materials. Magnesium based alloys are promising materials for storing hydrogen. They are generally made by argon melting and no attention has been payed to other fabrication techniques such as mechanical alloying or powder technique

  10. Compatibility of refrigerants and lubricants with elastomers

    Energy Technology Data Exchange (ETDEWEB)

    Hamed, G.R.; Seiple, R.H.

    1993-01-01

    The information contained in this report is designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. 97% of the swell measurements have been made to date. The other 3% of the measurements are contingent on availability of additional R-32. Swell behavior in the fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

  11. Uranium mining, atomic weapons testing, nuclear waste storage: A global survey. World Uranium Hearing grey book 1992

    International Nuclear Information System (INIS)

    Krumbholz, E.; Kressing, F.

    1992-09-01

    The first edition of the 'World Uranium Hearing Grey Book' for the World Uranium Hearing in Salzburg, 13-19 September 1992 is meant to be a reference for people involved in the World Uranium Hearing. It is mostly made up to country by country surveys giving background information on the testimonies presented at the Hearing, and on many more cases. Included are two short articles: One on 'nukespeak' to make the reader aware of how the language of the nuclear industry influences our speaking and thinking; and an article on the wastes produced by uranium mines. Due to limited time and resources this documentation is not complete. Many questions remain. For example, information is rare about conditions in Eastern Europe. Also, some countries are given much more space than others, which does not indicate importance or seriousness of implications of uranium mining, weapons testing or nuclear waste storage in this particular country. (orig./HP)

  12. The impact of biopreservatives and storage temperature in the quality and safety of minimally processed mixed vegetables for soup.

    Science.gov (United States)

    Alvarez, María V; Ponce, Alejandra G; Mazzucotelli, Cintia A; Moreira, María R

    2015-03-30

    The combined effects of bioactive agents (tea tree essential oil, propolis extract and gallic acid) and storage temperature on the microbiological and sensory quality of fresh-cut mixed vegetables for soup (celery, leek and butternut squash) were studied with the objective of preserving its quality and safety. Refrigeration temperature was confirmed as the main factor to limit the growth of spoilage and pathogenic microorganisms. Biopreservatives applied on mixed vegetables were effective only when combined with optimal refrigeration temperature (5 °C). Bioactive compounds showed slight effectiveness in controlling the microbiota present in mixed vegetables, although coliforms were greatly reduced by gallic acid and propolis treatments, achieving 0.5-2 log unit reductions during storage. Also, these agents showed antimicrobial activity against endogenous Escherichia coli and inoculated E. coli O157:H7, exerting a bacteriostatic effect and reducing population counts by 0.9-1.2 log CFU g(-1) at 10 days of refrigerated storage. The combination of propolis treatment with refrigerated storage conditions effectively preserved the sensory quality and prolonged the sensory shelf life of fresh-cut mixed vegetables by 3 days. The use of natural agents such as propolis extract to preserve the quality and safety of mixed vegetables for soup might be an interesting option to address the concerns of the consumer about the use of synthetic chemical antimicrobials potentially harmful to health. © 2014 Society of Chemical Industry.

  13. Effects of refrigerating preinoculated Vitek cards on microbial physiology and antibiotic susceptibility

    Science.gov (United States)

    Skweres, Joyce A.; Bassinger, Virginia J.; Mishra, S. K.; Pierson, Duane L.

    1992-01-01

    Reference cultures of 16 microorganisms obtained from the American Type Culture Collection and four clinical isolates were used in standardized solutions to inoculate 60 cards for each test strain. A set of three ID and three susceptibility cards was processed in the Vitek AutoMicrobic System (AMS) immediately after inoculation. The remaining cards were refrigerated at 4 C, and sets of six cards were removed and processed periodically for up to 17 days. The preinoculated AMS cards were evaluated for microorganism identification, percent probability of correct identification, length of time required for final result, individual substrate reactions, and antibiotic minimal inhibitory/concentration (MIC) values. Results indicate that 11 of the 20 microbes tested withstood refrigerated storage up to 17 days without detectable changes in delineating characteristics. MIC results appear variable, but certain antibiotics proved to be more stable than others. The results of these exploratory studies will be used to plan a microgravity experiment designed to study the effect of microgravity on microbial physiology and antibiotic sensitivity.

  14. Cooling of superconducting devices by liquid storage and refrigeration unit

    Science.gov (United States)

    Laskaris, Evangelos Trifon; Urbahn, John Arthur; Steinbach, Albert Eugene

    2013-08-20

    A system is disclosed for cooling superconducting devices. The system includes a cryogen cooling system configured to be coupled to the superconducting device and to supply cryogen to the device. The system also includes a cryogen storage system configured to supply cryogen to the device. The system further includes flow control valving configured to selectively isolate the cryogen cooling system from the device, thereby directing a flow of cryogen to the device from the cryogen storage system.

  15. High efficient ammonia heat pump system for industrial process water using the ISEC concept. Part 2

    DEFF Research Database (Denmark)

    Olesen, Martin F.; Madsen, Claus; Olsen, Lars

    2014-01-01

    The Isolated System Energy Charging (ISEC) concept allows for a high efficiency of a heat pump system for hot water production. The ISEC concept consists of two water storage tanks, one charged and one discharged. The charged tank is used for the industrial process, while the discharged tank...... is charging. The charging of the tank is done by recirculating water through the condenser and thereby gradually heating the water. The modelling of the system is described in Part I [1]. In this part, Part II, an experimental test setup of the tank system is reported, the results are presented and further...... modelling of the heat pump and tank system is performed (in continuation of Part I). The modelling is extended to include the system performance with different natural refrigerants and the influence of different types of compressors....

  16. The effect of combination treatment of gamma irradiation with refrigeration or with hot water treatment on the storage life and organoleptic properties of carabao mangoes and lacatan bananas

    International Nuclear Information System (INIS)

    Barruel, D.S.

    1976-03-01

    This study aims to determine the best combination of irradiation-hot water and irradiation-low temperature storage as treatments to help achieve longer shelf-life extension of fruits with export value such as bananas and mangoes. Results have shown the combined irradiation and hot water treatment as a better treatment for mangoes over that of combined irradiation (50kr) and low temperature storage (15 0 C) or of single treatments with irradiation, refrigeration or hot water. A much lower dose of 30 krad was found to give the longest extension in shelf-life in mangoes subjected to irradiation and hot (55 0 C) water treatment. No significant differences in the organoleptic properties were found in the samples given the combination treatment when compared to samples given no treatment at all. The extension in shelf-life may be attributed to the synergistic effect of the treatments, which could have affected the senescence of the fruit and likewise controlled the growth of rot-causing microorganisms. Similar work was also done on bananas but the results are still preliminary

  17. Refrigeration a history

    CERN Document Server

    Gantz, Carroll

    2015-01-01

    For thousands of years, humans coped with heat by harvesting and storing natural ice and devising natural cooling systems that utilized ventilation and evaporation. By the mid 1800s, people began developing huge refrigeration machines to manufacture ice. By the early 1900s, engineers developed electric domestic refrigerators, which by 1927 were affordable convenient household appliances. By then, an increasingly sophisticated public demanded more modern-looking appliances than engineers could produce, and a new breed of designers entered the manufacturing world to provide them. During the Depr

  18. Refrigerating liquid prototype for LED's thermal management

    International Nuclear Information System (INIS)

    Faranda, Roberto; Guzzetti, Stefania; Lazaroiu, George Cristian; Leva, Sonia

    2012-01-01

    The heat management is the critical factor for high performance operation of LED. A new heat management application of refrigerating liquid integrated within a fabricated prototype is proposed and investigated. A series of experiments considering different heights of liquid level were performed to evaluate the heat dissipation performance and optical characteristics of the refrigerating liquid based prototype. The results reveal that the junction temperature decreases as the level of refrigerating liquid increases. The experimental results report that the refrigerating liquid reduces the junction temperature, and can positively influence the luminous radiation performances. An optimization investigation of the proposed solution was carried out to find an optimum thermal performance. The experiments indicated that refrigerating liquid cooling is a powerful way for heat dissipation of high power LEDs, and the fabrication of prototype was feasible and useful. - Highlights: ► New heat management application of refrigerating liquid on a fabricated LED prototype. ► Thermal models setup and comparison between the classical and the new solutions. ► The impact of refrigerating liquid level on LED thermal and luminous performances. ► The relationship between different levels of liquid with LED prototype performances.

  19. IEA Annex 26: Advanced Supermarket Refrigeration/Heat Recovery Systems

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, VAN

    2003-05-19

    With increased concern about the impact of refrigerant leakage on global warming, a number of new supermarket refrigeration system configurations requiring significantly less refrigerant charge are being considered. In order to help promote the development of advanced systems and expand the knowledge base for energy-efficient supermarket technology, the International Energy Agency (IEA) established IEA Annex 26 (Advanced Supermarket Refrigeration/Heat Recovery Systems) under the ''IEA Implementing Agreement on Heat Pumping Technologies''. Annex 26 focuses on demonstrating and documenting the energy saving and environmental benefits of advanced systems design for food refrigeration and space heating and cooling for supermarkets. Advanced in this context means systems that use less energy, require less refrigerant and produce lower refrigerant emissions. Stated another way, the goal is to identify supermarket refrigeration and HVAC technology options that reduce the total equivalent warming impact (TEWI) of supermarkets by reducing both system energy use (increasing efficiency) and reducing total refrigerant charge. The Annex has five participating countries: Canada, Denmark, Sweden, the United Kingdom, and the United States. The working program of the Annex has involved analytical and experimental investigation of several candidate system design approaches to determine their potential to reduce refrigerant usage and energy consumption. Advanced refrigeration system types investigated include the following: distributed compressor systems--small parallel compressor racks are located in close proximity to the food display cases they serve thus significantly shortening the connecting refrigerant line lengths; secondary loop systems--one or more central chillers are used to refrigerate a secondary coolant (e.g. brine, ice slurry, or CO2) that is pumped to the food display cases on the sales floor; self-contained display cases--each food display case

  20. Project ANSICHT. Final repository concept and backfilling and sealing concept for the final repository site model SUeD; Projekt ANSICHT. Endlagerkonzept sowie Verfuell- und Verschlusskonzept fuer das Endlagerstandortmodell SUeD. Technischer Bericht

    Energy Technology Data Exchange (ETDEWEB)

    Jobmann, Michael; Lommerzheim, Andree

    2015-08-03

    In the frame of ANSICHT the methodology for the demonstration of safe enclosure for high-level heat generating radioactive wastes is described. The report is based on the safety requirements for final repository concepts and shows a first backfilling and sealing concept that was developed for the final repository site model SUeD. The final repository model SUeD is based on a horizontal line storage concept, the Gorleben (VSG) and ERATO container concept and the mine layout were adopted and adapted to the given conditions. The backfill and sealing concept includes migration barriers, line closures and shaft closures in the frame of a redundant and diverse enclosure system. For all technical and geotechnical barrier components the long-term functional requirements were defined. The backfilling concept of underground cavities considers the variety of possible cavities in the line and infrastructure areas.

  1. Mining: The beginning and the end of the nuclear cycle

    International Nuclear Information System (INIS)

    Walls, J.

    1991-01-01

    Mining is one of the world's oldest industries, with a rich history that has evolved into modern times. A new chapter in that history is currently being written in southeastern New Mexico at the Waste Isolation Pilot Plant (WIPP). The beginning phase of the nuclear industry occurred when uranium was mined from the underground and processed to develop the first fuel source for the nuclear industry. The WIPP may well be the final chapter in closing out the nuclear cycle by the disposal of nuclear waste 2,150 ft into the underground repository. The WIPP is a US Department of Energy project located ∼ 30 miles southeast of Carlsbad, New Mexico, where the nation's first underground engineered nuclear repository is being constructed. The WIPP site was selected because of its location amidst a 2,000-ft-thick bed that provides a remarkably stable rock formation for the permanent storage of nuclear waste. The WIPP has taken an industry that is steeped in the tradition of mining hard rock with brute force to yield the highest quantity and has married it to a concept that demands superior safety and has a conservative approach to produce the highest quality. The process has been refined and has produced cultural shock in the local attitude toward mining

  2. Space shuttle/food system. Volume 2, Appendix C: Food cooling techniques analysis. Appendix D: Package and stowage: Alternate concepts analysis

    Science.gov (United States)

    1974-01-01

    The relative penalties associated with various techniques for providing an onboard cold environment for storage of perishable food items, and for the development of packaging and vehicle stowage parameters were investigated in terms of the overall food system design analysis of space shuttle. The degrees of capability for maintaining both a 40 F to 45 F refrigerated temperature and a 0 F and 20 F frozen environment were assessed for the following cooling techniques: (1) phase change (heat sink) concept; (2) thermoelectric concept; (3) vapor cycle concept; and (4) expendable ammonia concept. The parameters considered in the analysis were weight, volume, and spacecraft power restrictions. Data were also produced for packaging and vehicle stowage parameters which are compatible with vehicle weight and volume specifications. Certain assumptions were made for food packaging sizes based on previously generated space shuttle menus. The results of the study are shown, along with the range of meal choices considered.

  3. Opportunities to integrate solar technologies into the Chilean lithium mining industry - reducing process related GHG emissions of a strategic storage resource

    Science.gov (United States)

    Telsnig, Thomas; Potz, Christian; Haas, Jannik; Eltrop, Ludger; Palma-Behnke, Rodrigo

    2017-06-01

    The arid northern regions of Chile are characterized by an intensive mineral mining industry and high solar irradiance levels. Besides Chile's main mining products, copper, molybdenum and iron, the production of lithium carbonate from lithium containing brines has become strategically important due to the rising demand for battery technologies worldwide. Its energy-intensive production may affect the ecological footprint of the product and the country's climate targets. Thus, the use of solar technologies for electricity and heat production might constitute an interesting option for CO2 mitigation. This study aims to quantify the impacts of the lithium carbonate production processes in Chile on climate change, and to identify site-specific integration options of solar energy technologies to reduce GHG life-cycle emissions. The considered solar integration options include a parabolic trough power plant with a molten salt storage, a solar tower power plant with molten salt receiver and molten salt storage, a one-axis tracking photovoltaic energy system for electricity, and two solar thermal power plants with Ruths storage (steam accumulator) for thermal heat production. CSP plants were identified as measures with the highest GHG mitigation potential reducing the CO2 emissions for the entire production chain and the lithium production between 16% and 33%. In a scenario that combines solar technologies for electricity and thermal energy generation, up to 59% of the CO2 emissions at the lithium production sites in Chile can be avoided. A comparison of the GHG abatement costs of the proposed solar integration options indicates that the photovoltaic system, the solar thermal plant with limited storage and the solar tower power plant are the most cost effective options.

  4. Extending the shelf-life of cocoyam leaves(xanthosoma sagitifolium) through blanching, irradiation and low temperature storage

    International Nuclear Information System (INIS)

    Afrifa, J.T.

    2013-07-01

    Cocoyam leaf (Xanthosoma sagiitifolium) (,Kontommire') is arguably one of the most readily available and cheap indigenous leafy vegetable that is commonly consumed in Ghana. It is noted to be a good source of minerals, vitamins and soluble fibre when consumed in its fresh (not raw though) state. However, this vegetable is highly perishable. Dehydration methods and jute sack storage are usually used for its preservation. However, these lead to discolouration, loss of some nutrients, and exposure to microbial contamination thus reducing the general acceptability by consumers. In view of this, a study was conducted to process and preserve the leaves in their fresh state. Preservation methods investigated were: refrigeration, steam blanching, gamma irradiation and a combination of these methods. The effect of the various preservation methods on some physicochemical properties (moisture content and dry matter by gravimetric method, vitamin C (ascorbic acid) was determined by iodometric titration method, crude protein was determined by Kjeldahl method, colour change using a Minolta CR310 colorimeter, pH using the Mettler Toledo pH meter (model:T3KfTLH); phytochemical properties (total phenolic using the Folin ciocalteau method and total flavonoids using aluminium chloride colorimetric method); microbial quality (total viable count, total coliforms, yeast and moulds count using serial dilution); consumer acceptance using a 9-point hedonic scale to assess the colour, texture and odour. The best packaging material for effective storage was also investigated. Fresh, fully opened leaves of cocoyam which were two (2) weeks old were collected from the Biotechnology and Nuclear Agriculture Research Institute (BNARI) farm and used for the study. They were decontaminated by washing in fifty (50) % of brine solution and shredded and apportioned for the various treatments, packaged into zip-lock polyethylene bags and hermetically sealed bags. The shelf-life study lasted for

  5. Energy optimisation of domestic refrigerators

    DEFF Research Database (Denmark)

    Jakobsen, Arne; Rasmussen, Bjarne D.

    1998-01-01

    This paper describes the main results of a research project with the objective of reducing the energy consumption of domestic refrigerators by increasing the efficiency of the refrigeration system. The improvement of the system efficiency was to be obtained by:1) Introducing continuous operation ...

  6. Operating Manual of Helium Refrigerator (Rev. 2)

    Energy Technology Data Exchange (ETDEWEB)

    Song, K.M.; Son, S.H.; Kim, K.S.; Lee, S.K.; Kim, M.S. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    A helium refrigerator was installed as a supplier of 20K cold helium to the cryogenic distillation system of WTRF pilot plant. The operating procedures of the helium refrigerator, helium compressor and auxiliary apparatus are described for the safety and efficient operation in this manual. The function of the helium refrigerator is to remove the impurities from the compressed helium of about 250psig, to cool down the helium from ambient temperature to 20K through the heat exchanger and expansion engine and to transfer the cold helium to the cryogenic distillation system. For the smoothly operation of helium refrigerator, the preparation, the start-up, the cool-down and the shut-down of the helium refrigerator are described in this operating manual. (author). 3 refs., 14 tabs.

  7. Manufacturing A Refrigerator with Heat Recovery Unit

    Directory of Open Access Journals (Sweden)

    Mustafa Mohammed Kadhim

    2018-02-01

    Full Text Available This study aims to exploite the rejected heating energy from condenser and benefit from it to reheat the foods and other materials. It can also be employed to improve the coefficient of performance of a refrigerator at the same time by using approximately the same consumption electrical energy used to operate the compressor and refrigerator in general. This idea has been implemented by manufacturing of a refrigerator with using additional part has the same metal and condenser pipe diameters but its surface area does not exceed 40% from total surface area of the condenser and its design as an insulated cabinet from all sides to prevent heat leakage through it and located between the compressor and the condenser. Small electrical fan has been added inside this cabinet to provide a suitable air circulation and a homogenous temperature distribution inside the cabinet space. It is expected that the super heating energy of refrigerant (R134a which comes out of the compressor would be removed  inside this cabinet and this insist to condensate the refrigerant (cooling fluid with a rate higher than that used in the normal refrigerator only. Three magnetic valves have been used in order to control the refrigerant flow in state of operation the refrigerator only or to gather with heating cabinet. To measure the temperatures at each process of the simple vapor compression refrigeration cycle, nine temperature sensors at input and output of each compressor, condenser and an evaporator in additional to input of cabinet and inside it and on evaporator surface have been provided. Five pressure gages have been used to measure the value of pressure and compare it for the two states of operation. The consumption of electrical energy  can be calculated by adding an ammeter and a voltmeter and compare between the consumption energy of both states. The obtained results show that there is an improvement in the coeffecient of performance in state of operation the

  8. HFC perspectives in air-conditioning and refrigeration; Perspectives HFC en A/C et refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Fauvarque, P [ELF Atochem, Centre d` Application de Lavallois, 92 (France)

    1998-12-31

    This paper is a series of transparencies dealing with the development of substitutes for the replacement of the R-22 refrigerant in air-conditioning systems (R-134a, R-407C, R-410A), and in industrial refrigeration systems of agriculture and food industry (R-134a and R-404A). (J.S.)

  9. HFC perspectives in air-conditioning and refrigeration; Perspectives HFC en A/C et refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Fauvarque, P. [ELF Atochem, Centre d`Application de Lavallois, 92 (France)

    1997-12-31

    This paper is a series of transparencies dealing with the development of substitutes for the replacement of the R-22 refrigerant in air-conditioning systems (R-134a, R-407C, R-410A), and in industrial refrigeration systems of agriculture and food industry (R-134a and R-404A). (J.S.)

  10. Mining planing introduction

    International Nuclear Information System (INIS)

    Toledo, R.D.

    1985-01-01

    Basic concepts concerning mining parameters, plan establishment and typical procedure methods applied throughout the physical execution of mining operations are here determined, analyzed and discussed. Technological and economic aspects of the exploration phase are presented as well as general mathematical and statistical methods for estimating, analyzing and representing mineral deposits which are virtually essential for good mining project execution. The characterization of important mineral substances and the basic parameters of mining works are emphasized in conjunction with long, medium and short term mining planning. Finally, geological modelling, ore reserves calculations and final economic evaluations are considered using a hypothetical example in order to consolidate the main elaborated ideas. (D.J.M.) [pt

  11. Rotary magnetic refrigerator for superfluid helium production

    International Nuclear Information System (INIS)

    Hakuraku, Y.; Ogata, H.

    1986-01-01

    A new rotary-magnetic refrigerator designed to obtain superfluid helium temperatures by executing a magnetic Carnot cycle is developed. A rotor containing 12 magnetic refrigerants (gadolinium-gallium-garnet) is immersed in liquid helium at 4.2 K and rotated at constant speed in a steady magnetic field distribution. Performance tests demonstrate that the new rotary refrigerator is capable of obtaining a temperature of 1.48 K. The maximum useful cooling power obtained at 1.8 K is 1.81 W which corresponds to a refrigeration efficiency of 34%

  12. Effect of chitosan enriched with lycopene coating on fatty acid profile and fat oxidation parameters of rainbow trout fillet during refrigerated storage(orginal reserch article

    Directory of Open Access Journals (Sweden)

    Seyede Samane Naghibi

    2016-05-01

    Full Text Available Fish are the major dietary source of the polyunsaturated fatty acid for humans. Therefore, protection of fish against all types of oxidative corruption seems to be necessary. Lycopene is the source of natural antioxidant. The present study was conducted to evaluate antioxidant properties of lycopene (using the method of DPPH and the combined effect of its various doses (1.5 and 3% and chitosan on fat oxidation parameters and fatty acids composition of Rainbow trout fillet. The analysis was performed after 0, 8 and 16 days of storage of the samples at 4°C to determine peroxide value (PV and free fatty acid content (FFA. In addition, fatty acid compositions was determined by Gas chromatography assay. In control treatment, the fatty acid composition of Rainbow trout fillet was consisted of %20.6±0.03 saturated fatty acids (SFA, %43.81±0.04 monounsaturated fatty acid (MUFA and %32.83±0.03 polyunsaturated fatty acids (PUFAs in 0 day. Statistical analysis showed that there were fewer changes in PV, FFA and proportion of fatty acids between chitosan and lycopene-chitosan treatment in regard to control sample during 16 days of refrigeration storage. Chitosan coated samples enriched with lycopene exhibited less rapidly lipid damages than all the other samples (p

  13. New magnetic refrigeration materials for the liquefaction of hydrogen

    International Nuclear Information System (INIS)

    Gschneidner, K.A.; Takeya, H.; Moorman, J.O.; Pecharsky, V.K.; Malik, S.K.; Zimm, C.B.

    1994-01-01

    Five heavy lanthanide ferromagnetic intermetallic compounds were studied as potential magnetic refrigerants for the liquefaction of hydrogen gas. (Dy 0.5 Er 0.5 )Al 2 and TbNi 2 appear to be better refrigerants than GdPd for a Joule-Brayton cycle refrigerator, while (Gd 0.54 Er 0.46 )AlNi seems to be a suitable refrigerant for an Ericsson cycle refrigerator

  14. CONCEPTION OF THE TRACK SYSTEM FOR „DĘBIEŃSKO 1” MINING PLANT

    Directory of Open Access Journals (Sweden)

    Ryszard MIELIMĄKA

    2016-07-01

    Full Text Available This article presents two concepts of site development for the „Dębieńsko 1” mining plant including plans for the track system. The first plan was created in 2013 year and mainly assumed the renovation of railway infrastructure, without changing its shape and configuration. In 2014 year it was resigned from realization of the first conception and there was proposed the second plan. It included changes in the existing track system and project of the new system of excavated raw material haulage. This system is successfully using in the USA and provides the better work productivity of a shunting locomotive. In this article also were indicated the advantages and the disadvantages of solutions proposed in the two projects of site development plans. It was denoted the project that has ultimately been chosen with the justification of choice.

  15. Underground coal mining technology - the future

    Energy Technology Data Exchange (ETDEWEB)

    Lama, R P [Kembla Coal and Coke Pty Limited, Wollongong, NSW (Australia)

    1989-01-01

    Discusses development of underground coal mining in Australia in the last four decades. The following aspects are reviewed: technology for underground mining (longwall mining, unidirectional cutting, bidirectional cutting, operation of more than one shearer on a working face, optimum dimensions of longwall blocks), longwall productivity (productivity increase will depend on increasing the availability factor of equipment, reducing failures due to human errors, organizational models, improving on-site decision making, improving monitoring, maintenance, planning and scheduling, concept of 'Transparent Mine'), roadway development systems (types of heading machines, standard systems for mine drivage and roof bolting and their productivity), size of coal mines, man and material transport systems (20,000-30,000 t/d from a single longwall face, mine shafts with a diameter 9-10 m), mine layout design (layout of longwall blocks, main intakes and returns situated in rock layers), mine environmental systems (ventilation systems, gas control), management, training and interpersonal relationships. Future coal mines will be developed with an integral capacity of 8-10 Mt/a from a single longwall operation with main development arteries placed in rocks. Development of gate roadways will require novel solutions with continuous cutting, loading and bolting. Information technology, with the concept of 'transparent mine', will form the backbone of decision making.

  16. Reasearch and Evaluation of Electromagnetic Fields of Refrigerators

    Directory of Open Access Journals (Sweden)

    Pranas Baltrėnas

    2013-12-01

    Full Text Available The use of refrigerators causes the occurence of electromagnetic fields that are invisible and intangible, which therefore makes difficulties in protecting ourselves from them. A refrigerator is an irreplaceable item in domestic household and thus can be hardly ignored by a modern way of human life. In order to preserve the characteristics of products, the refrigerator must operate continuously (24 hrs a day, regardless of the time of the year. This results in a huge increase in electricity consumption, which leads to energy consumption related pollution of the environment emitting CO2 gas. On these grounds, it is necessary to assess electromagnetic fields created by the refrigerator. Studies on electromagnetic fields produced by refrigerators were conducted in domestic premises where people spent a significant part of the day. For comparison purposes, five different power refrigerators were chosen (1 – 0.20 kW; 2 – 0.25 kW; 3 – 0.30 kW; 4 – 0.35 kW; 5 – 0.40 kW. The obtained results, according to the parameters of their electromagnetic fields, were presented in graphs and charts and showed that the values of electric and magnetic intensity of refrigerators depended on the distance and the power of the refrigerator. The conducted research also disclosed that none of tested refrigerators exceeded the permissible limits of electromagnetic fields.Article in Lithuanian

  17. Krypton based adsorption type cryogenic refrigerator

    Science.gov (United States)

    Jones, Jack A. (Inventor); Schember, Helene R. (Inventor)

    1989-01-01

    Krypton and a monolithic porous carbon such as Saran carbon are used respectively as the sorbate and sorbent of an adsorption type refrigerator to improve refrigeration efficiency and operational longevity.

  18. Unmanned Mine of the 21st Centuries

    Science.gov (United States)

    Semykina, Irina; Grigoryev, Aleksandr; Gargayev, Andrey; Zavyalov, Valeriy

    2017-11-01

    The article is analytical. It considers the construction principles of the automation system structure which realize the concept of «unmanned mine». All of these principles intend to deal with problems caused by a continuous complication of mining-and-geological conditions at coalmine such as the labor safety and health protection, the weak integration of different mining automation subsystems and the deficiency of optimal balance between a quantity of resource and energy consumed by mining machines and their throughput. The authors describe the main problems and neck stage of mining machines autonomation and automation subsystem. The article makes a general survey of the applied «unmanned technology» in the field of mining such as the remotely operated autonomous complexes, the underground positioning systems of mining machines using infrared radiation in mine workings etc. The concept of «unmanned mine» is considered with an example of the robotic road heading machine. In the final, the authors analyze the techniques and methods that could solve the task of underground mining without human labor.

  19. Cooperative work program between ERDA/OWI and the Swedish State Power Board on waste storage in mined caverns

    International Nuclear Information System (INIS)

    Witherspoon, P.A.

    1977-01-01

    Recent conferences between members of OWI and LBL, and members of the Swedish State Power Board have revealed that an abandoned iron ore mine in Stripa, Sweden, can be used in a very profitable manner for a cooperative work program on the problem of radioactive waste storage in mined caverns. The main thrust of this cooperative work program will be to determine the feasibility of using a mined cavern in hard rock as a permanent repository for high level radioactive materials. The ERDA/OWI program is directed along different lines that complement the Swedish program. Seven tasks are involved as follows: Task 1 will investigate over a two-year period the temperature effects in the granite rock mass at Stripa using a full scale electric heater that simulates the energy output of radioactive waste canisters. Task 2 will determine the long term effect of waste heat in a fractured rock mass. Task 3 will assess the fracture hydrology in the Stripa mine. Task 4 will involve geophysical measurements to determine the locations of the fracture system in the granite rock mass. Task 5 is a laboratory investigation on the measurement of rock properties that are urgently needed in the overall problem of evaluating repository sites in the U.S. Task 6 will involve a method of measuring the gross seepage rate in the low permeability granitic rocks at Stripa. Task 7 will determine the virgin state of stress in the fractured granite rock mass at Stripa

  20. Viability and Biochemical Content Changes in Seed Storage of Jabon Putih (Anthocephalus Cadamba (Roxb Miq.

    Directory of Open Access Journals (Sweden)

    Naning Yuniarti

    2015-08-01

    Full Text Available Seed deterioration is the process of deteriorated seed in view of viability that changed the physiological and chemical content. The aim of this research is to find out the effect of moisture content and storage on viability and biochemical content of jabon putih seed. Completely Randomized Design was used for decreasing moisture content based on seed drying time for 0, 24, 48, 72, 96, 120 hours, and Completely Randomized Factorial Design was used for the combination of moisture content (drying time for 0, 24, 48, 72, 96, 120 hours and room storage (ambient room, air-conditioned room, refrigerator. The results of this research are: (1 seed drying time and seed storage affected the change of seed viability and biochemical content, (2 seed drying time and seed storage influence significantly the value of moisture content, germination percentage, and biochemical content (lipid, carbohydrate, protein, (3 The longer time of seed drying and seed storage has decreased the seed moisture content, germination percentage, and the carbohydrate content, but it has increased the content of lipid and protein, and (4 the seeds were stored in refrigerator has better viability compared to dry cold storage and ambient room.

  1. Auto-refrigerating cascade for superconducting applications

    International Nuclear Information System (INIS)

    Forrest, S.M.; Hall, P.H.; Missimer, D.J.

    1987-01-01

    Extremely low temperatures, in the range of 230 to 90 K, are achieved in a single circuit compression refrigeration system operated by a conventional compressor. The system relies upon a series of intermediate cooling stages. The refrigerant is a mixture and the system employs fractional condensation, distillation, phase separation and intermediate heat transfer. Each stage includes the steps of withdrawing a portion of the liquid condensate from the compressed vapor-liquid refrigerant mixture which enters the stage. The withdrawn condensate is then throttled to a lower pressure and is mixed with the refrigerant being recycled to the compressor from the final evaporator. Evaporating the throttled condensate absorbs heat from and at least partially condenses the compressed uncondensed vapor in the compressed mixture

  2. 46 CFR 147.90 - Refrigerants.

    Science.gov (United States)

    2010-10-01

    .../ASHRAE 34-78 may be carried as ships' stores. (b) Refrigerants contained in a vessel's operating system... 46 Shipping 5 2010-10-01 2010-10-01 false Refrigerants. 147.90 Section 147.90 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DANGEROUS CARGOES HAZARDOUS SHIPS' STORES Stowage and Other...

  3. Artificial intelligent methods for thermodynamic evaluation of ammonia-water refrigeration systems

    International Nuclear Information System (INIS)

    Sencan, Arzu

    2006-01-01

    In this paper, Linear Regression and M5'Rules models within Data Mining Process and Artificial Neural Network (ANN) model for thermodynamic evaluation of ammonia-water absorption refrigeration systems was carried out. A new formulation based on ANN model is presented for the analysis of ammonia-water absorption refrigeration systems (AWRS) because the optimal result was obtained by using ANN Model. Thermodynamic analysis of the AWRS is very complex because of analytic functions used for calculating the properties of fluid couples and simulation programs. Therefore, it is extremely difficult to perform analysis of this system. COP and f are estimated depending on the temperatures of system component and concentration values. Using the weights obtained from the trained network a new formulation is presented for the calculation of the COP and f; the use of ANN is proliferating with high speed in simulation. The R 2 -values obtained when unknown data were used to the networks was 0.9996 and 0.9873 for the circulation ratio and COP respectively which is very satisfactory. The use of this new formulation, which can be employed with any programming language or spreadsheet program for the estimation of the circulation ratio and COP of AWRS, as described in this paper, may make the use of dedicated ANN software unnecessary

  4. Effects of low-level gamma irradiation on the characteristics of fermented pork sausage during storage

    International Nuclear Information System (INIS)

    Kim, I.S.; Jo, C.; Lee, K.H.; Lee, E.J.; Ahn, D.U.; Kang, S.N.

    2012-01-01

    The effect of gamma irradiation (0.5, 1, 2, and 4 kGy) on the quality of vacuum-packaged dry fermented sausages during refrigerated storage was evaluated. At Day 0 of irradiation, the pH, redness (CIE a ⁎ ), yellowness (CIE b ⁎ ), 2-thiobarbituric acid-reactive substances (TBARS) and volatile basic nitrogen (VBN) values of samples irradiated at 2 and 4 kGy were higher (p ⁎ values (lightness) were lower than those of the non-irradiated control (p ⁎ , CIE a ⁎ and CIE b ⁎ -value of samples were not significantly influenced by irradiation. The CIE a ⁎ , and CIE b ⁎ -values of samples irradiated at 2 and 4 kGy decreased with the increase of storage time. The VBN, TBARS, and CIE L ⁎ -values of samples irradiated at 4 kGy were not changed significantly during refrigerated storage for 90 days (p>0.05). The total plate counts (TPC) and lactic acid bacteria (LAB) in the samples irradiated at 4 kGy were significantly lower (p<0.01) than those with lower irradiation doses. At the end of storage, the TPC, coliform, and LAB in the samples were not increased after irradiation at 1, 0.5 and 1 kGy, respectively. TPC and LAB were not detected in samples irradiated at 4 kGy at Day 90. In addition, no coliform bacteria were found in samples irradiated at 1 kGy during refrigerated storage. Sensory evaluation indicated that the rancid flavor of samples irradiated at 4 kGy was significantly higher, but aroma and taste scores were lower than those of the control at Day 3 of storage. Irradiation of dry fermented sausages at 2 kGy was the best conditions to prolong the shelf-life and decrease the rancid flavor without significant quality deterioration. - Highlights: ► Effect of gamma irradiation on the quality of vacuum-packaged dry fermented sausages during refrigerated storage was evaluated. ► At Day 90, the TPC, coliform, and LAB in the dry fermented sausages were not increased after irradiation at 2, 0.5 and 4 kGy, respectively. ► TPC and LAB were not detected in

  5. 46 CFR 111.79-15 - Receptacles for refrigerated containers.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Receptacles for refrigerated containers. 111.79-15... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Receptacles § 111.79-15 Receptacles for refrigerated containers. Receptacles for refrigerated containers must meet one of the following: (a) Each receptacle for refrigerated...

  6. Modular vault dry storage system for interim storage of irradiated fuel

    International Nuclear Information System (INIS)

    Cundill, B.R.; Ealing, C.J.; Agarwal, B.K.

    1988-01-01

    The Foster Wheeler Energy Application (FWEA) Modular Vault Dry Store (MVDS) is a dry storage concept for the storage of all types of irradiated reactor fuel. For applications in the US, FWEA submitted an MVDS Topical Report to the US NRC during 1986. Following NRC approval of the MVDS Topical Report concept for unconsolidated LWR fuel, US utilities have available a new, compact, economic and flexible system for the storage of irradiated fuel at the reactor site for time periods of at least 20 years (the period of the first license). The MVDS concept jointly developed by FWEA and GEC in the U.K., has other applications for large central away from reactor storage facilities such as a Monitorable Retrievable Storage (MRS) installation. This paper describes the licensed MVDS design, aspects of performance are discussed and capital costs compared with alternative concepts. Alternative configurations of MVDS are outlined

  7. KSTAR Helium Refrigeration System Design and Manufacturing

    International Nuclear Information System (INIS)

    Dauguet, P.; Briend, P.; Abe, I.; Fauve, E.; Bernhardt, J.-M.; Andrieu, F.; Beauvisage, J.

    2006-01-01

    The tokamak developed in the KSTAR (Korean Superconducting Tokamak Advanced Research) project makes intensive use of superconducting magnets operated at 4.5 K. The cold components of the KSTAR tokamak require forced flow of supercritical helium for magnets/structure, boiling liquid helium for current leads, and gaseous helium for thermal shields. The cryogenic system will provide stable operation and full automatic control. A three-pressure helium cycle composed of six turbines has been customised design for this project. The '' design '' operating mode results with a system composed of a 9 kW refrigerator (including safety margin) and using gas and liquid storages for mass balancing. During Shot/Standby mode, the heat loads are highly time-dependent. A thermal damper is used to smooth these variations and will allow stable operation. (author)

  8. THE STIRLING GAS REFRIGERATING MACHINE MECHANICAL DESIGN IMPROVING

    Directory of Open Access Journals (Sweden)

    V. V. Trandafilov

    2016-06-01

    Full Text Available To improve the mechanical design of the piston Stirling gas refrigeration machine the structural optimization of rotary vane Stirling gas refrigeration machine is carried out. This paper presents the results of theoretical research. Analysis and prospects of rotary vane Stirling gas refrigeration machine for domestic and industrial refrigeration purpose are represented. The results of a patent search by mechanisms of transformation of rotary vane machines are discussed.

  9. THE STIRLING GAS REFRIGERATING MACHINE MECHANICAL DESIGN IMPROVING

    Directory of Open Access Journals (Sweden)

    V. V. Trandafilov

    2016-02-01

    Full Text Available To improve the mechanical design of the piston Stirling gas refrigeration machine the structural optimization of rotary vane Stirling gas refrigeration machine is carried out. This paper presents the results of theoretical research. Analysis and prospects of rotary vane Stirling gas refrigeration machine for domestic and industrial refrigeration purpose are represented. The results of a patent search by mechanisms of transformation of rotary vane machines are discussed

  10. Post-mining safety implementations and environmental aspects of abandoned mine sites in Limousin. 2006 status (and perspectives 2007); Mises en securite en apres-mine et aspects environnementaux des anciens sites miniers en Limousin. Bilan 2006 (et perspectives 2007)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    This document summarizes the actions carried out in 2006 at some French abandoned mine sites: 1 - safety implementations and risks abatement in the framework of post-mining actions: coal mines of Ahun (23) and Argentat (19), antimony mines of Biard (87); 2 - remedial actions at the tin/tungsten mine of Puy-les-Vignes (87) and at the gold mine of Chatelet (23); 3 - 2007 post-mining perspectives; 4 - environmental aspects of abandoned mine sites: gold mines of Chatelet (23), Cheni and Bourneix (87), uranium mines of Haute-Vienne (expertise, control of effluents, financial warranties about tailings storage sites maintenance). (J.S.)

  11. Effect of Storage Time and Temperature on Dimensional Stability of Impressions Made with Zinc Oxide Impression Paste

    Directory of Open Access Journals (Sweden)

    Sareh Habibzadeh

    2016-10-01

    Full Text Available Objectives: This study aimed to assess the effect of storage time and temperature on dimensional stability of impressions made with Cavex Outline zinc oxide impression paste.Materials and Methods: A round stainless steel mold with five grooves (three horizontal and two vertical was used in this in-vitro experimental study. Cavex Outline impression paste was prepared according to the manufacturer’s instructions and applied to the mold. The mold was placed on a block and stored at 35°C and 100% humidity for setting. The impressions were poured with stone immediately and also after 30, 120, 240 and 420 minutes and 24 hours. The distance between the vertical lines on the casts was measured and compared with that in the immediately poured cast.Results: Storage in a refrigerator and at room temperature for zero to seven hours had no significant effect on dimensional stability of the impressions; however, 24 hours of storage in a refrigerator or at room temperature decreased the dimensional stability of Cavex Outline (P=0.001. Also, a significant association was found between dimensional changes following 24 hours of storage in a refrigerator (4°C and at room temperature (23°C; P<0.01.Conclusions: The optimal pouring time of Cavex Outline impressions with stone is between zero to seven hours, and 24 hours of storage significantly decreases the dimensional stability.Keywords: Dental Impression Materials; Zinc Oxide; Cavex

  12. Phisyological quality of Pinus elliotti Engelm. seeds subjected to differents storage methods

    Directory of Open Access Journals (Sweden)

    Adriano Geraldo Fonseca

    2012-09-01

    Full Text Available Due to the growing demand for forest products, it is necessary to increase knowledge about the tree species of economic importance, especially in relation to seed storage. One method to study forest species is the storage of seeds. Cryopreservation is the cheapest and the most efficient method of seed preservation. The objective of this study was to test the behavior of Pinus elliottii Engelm. seeds storaged on liquid nitrogen; laboratory environment and refrigerator. The experiment was conducted in the seed Laboratory of the Federal University of the Jequitinhonha and Mucuri Valley. The seeds were donated by Rigesa Ltda on June 2007. Three types of storage were tested: 1 liquid nitrogen temperature of -196 º C, 2 laboratory environment, 3 refrigerator. All treatments were evaluated at 0, 40, 80 and 120 days of storage. The vigor, germination and germination rate tests were mounted on gerbox with blotters and moistened with distilled water and kept in BOD incubator chamber at 25 º C. Seeds length, green mass and dry mass were also evaluated. The data were subjected to analysis of variance and means compared by Tukey test at 5% significance level. It was found that there was loss of quality of the Pinus elliottii seeds in all treatments. Cryopreservation of P. elliotii seeds can be used as an alternative of storage in genebanks.

  13. Adsorption refrigeration technology theory and application

    CERN Document Server

    Wang, Ruzhu; Wu, Jingyi

    2014-01-01

    Gives readers a detailed understanding of adsorption refrigeration technology, with a focus on practical applications and environmental concerns Systematically covering the technology of adsorption refrigeration, this book provides readers with a technical understanding of the topic as well as detailed information on the state-of-the-art from leading researchers in the field. Introducing readers to background on the development of adsorption refrigeration, the authors also cover the development of adsorbents, various thermodynamic theories, the design of adsorption systems and adsorption refri

  14. Refrigeration plants using carbon dioxide as refrigerant: measuring and modelling the solubility and diffusion of carbon dioxide in polymers used as sealing materials

    DEFF Research Database (Denmark)

    von Solms, Nicolas; Kristensen, Jakob

    2010-01-01

    Because of increased environmental pressure, there is currently a movement away from more traditional refrigerants such as HCFC's toward refrigerants with lower global warming potential such as carbon dioxide (CO2). However, the use of CO2 as a refrigerant requires a refrigeration cycle...

  15. Adsorption cold storage system with zeolite-water working pair used for locomotive air conditioning

    International Nuclear Information System (INIS)

    Lu, Y.Z.; Wang, R.Z.; Zhang, M.; Jiangzhou, S.

    2003-01-01

    Adsorption cold storage has lately attracted attention for its large storage capacity and zero cold energy loss during the storing process. Thermodynamic and experimental studies on the cold storage capacity and the cold discharging process, in which the adsorber is either air cooled or adiabatic, have been presented. An adsorption cold storage system with zeolite-water working pair has been developed, and some operating results are summarized. This system is used for providing air conditioning for the driver's cab of an internal combustion locomotive. Unlike a normal adsorption air conditioner, the system starts running with the adsorption process, during which the cold energy stored is discharged, and ends running with the generation process. The adsorbent temperature decreases during the cold storing period between two runs. The refrigeration power output for the whole running cycle is about 4.1 kW. It appears that such a system is quite energetically efficient and is comparatively suitable for providing discontinuous refrigeration capacity when powered by low grade thermal energy, such as industrial exhausted heat or solar energy

  16. Geological storage of CO2

    International Nuclear Information System (INIS)

    Czernichowski-Lauriol, I.

    2005-01-01

    The industrial storage of CO 2 is comprised of three steps: - capture of CO 2 where it is produced (power plants, cement plants, etc.); - transport (pipe lines or boats); - storage, mainly underground, called geological sequestration... Three types of reservoirs are considered: - salted deep aquifers - they offer the biggest storage capacity; - exhausted oil and gas fields; - non-exploited deep coal mine streams. The two latter storage types may allow the recovery of sellable products, which partially or totally offsets the storage costs. This process is largely used in the petroleum industry to improve the productivity of an oil field, and is called FOR (Enhanced Oil Recovery). A similar process is applied in the coal mining industry to recover the imprisoned gas, and is called ECBM (Enhanced Coal Bed methane). Two storage operations have been initiated in Norway and in Canada, as well as research programmes in Europe, North America, Australia and Japan. International organisations to stimulate this technology have been created such as the 'Carbon Sequestration Leadership Forum' and 'the Intergovernmental Group for Climate Change'. This technology will be taken into account in the instruments provided by the Tokyo Protocol. (author)

  17. Development of concepts for low-cost energy storage assemblies for annual cycle energy system applications

    Science.gov (United States)

    Alexander, G. H.; Cooper, D. L.; Cummings, C. A.; Reiber, E. E.

    1981-10-01

    Low cost energy storage assemblies were developed. In the search for low overall cost assemblies, many diverse concepts and materials were postulated and briefly evaluated. Cost rankings, descriptions, and discussions of the concepts were presented from which ORNL selected the following three concepts for the Phase 2 development: (1) a site constructed tank with reinforced concrete walls formed with specialized modular blocks which eliminates most concrete form work and provides integral R-20 insulation designated ORNLFF; (2) a site constructed tank with earth supported walls that are formed from elements common to residential, in-ground swimming pools, designated SWPL; (3) and a site assembled tank used in underground utility vaults, designated UTLBX. Detailed designs of free standing versions of the three concepts are presented.

  18. Refrigeration system having standing wave compressor

    Science.gov (United States)

    Lucas, Timothy S.

    1992-01-01

    A compression-evaporation refrigeration system, wherein gaseous compression of the refrigerant is provided by a standing wave compressor. The standing wave compressor is modified so as to provide a separate subcooling system for the refrigerant, so that efficiency losses due to flashing are reduced. Subcooling occurs when heat exchange is provided between the refrigerant and a heat pumping surface, which is exposed to the standing acoustic wave within the standing wave compressor. A variable capacity and variable discharge pressure for the standing wave compressor is provided. A control circuit simultaneously varies the capacity and discharge pressure in response to changing operating conditions, thereby maintaining the minimum discharge pressure needed for condensation to occur at any time. Thus, the power consumption of the standing wave compressor is reduced and system efficiency is improved.

  19. 2016 German refrigeration and air conditioning meeting. Proceedings; Deutsche Kaelte- und Klimatagung 2016. Tagungsbericht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-07-01

    The following topics were dealt with: Large cryogenic facilities, relief valves, liquid helium, liquid-nitrogen and liquid hydrogen cooling, new concepts, foundations and materials of the heat-pump techniques, evaporation, phase-change materials, absorption, afterheat usage, ionic liquids, sorption, condensers, heat exchangers, back-cooling systems, refrigerants, caron dioxide, mobile applications, efficiency and optimization, air conditioning.

  20. Ultimate storage of spent fuel elements of the AVR test power station in the Asse salt mine

    International Nuclear Information System (INIS)

    Wolf, J.

    1975-02-01

    With regard to the ultimate storage of irradiated AVR pebble-bed reactor carbide fuel elements in the saline of Asse, a number of tests and calculations are presented to demonstrate that there is no credible possibility of the MCA (maximum credible accident) defined for the saline. The safety of persons is not threatened during the operation of spent fuel storage nor at any later time (extrapolation up to approx. 1,000 years after storage). 1,000 fuel elements at a time are packed up in gas-tight containers which are stacked in boreholes. The boreholes are then sealed with concrete. Lay-out and functions of the special airlock and transportation systems - from the packing of the containers in a hot cell to the final storage in the borehole - are described with special reference to aspects of the safety of the overall procedure. The possible accidents in the mine are discussed in detail. 85 Kr and T release rates are determined in laboratory tests by heating of the spherical fuel elements. Tests with fuel elements embedded in salt or stagnant brine were carried out at varies temperatures to investigate their behaviour in final storage. Kr and T release, extraction of fission products, mechanical resistance and corrosion were examined in these tests. Finally, the permeability of salt and salt concrete to radioactive gases were investigated in a special experimental arrangement. The diffusion and permeability coefficients obtained for 85 Kr, HT and HTO allow an estimation of the gas discharge of the stored fuel element. (RB/AK) [de